Sample records for head metal-on-metal cementless

  1. Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    van Raaij Jos JAM

    2008-10-01

    Full Text Available Abstract Background Osteoarthritis of the hip is successfully treated by total hip arthroplasty with metal-on-polyethylene articulation. Polyethylene wear debris can however lead to osteolysis, aseptic loosening and failure of the implant. Large head metal-on-metal total hip arthroplasty may overcome polyethylene wear induced prosthetic failure, but can increase systemic cobalt and chromium ion concentrations. The objective of this study is to compare two cementless total hip arthroplasties: a conventional 28 mm metal-on-polyethylene articulation and a large head metal-on-metal articulation. We hypothesize that the latter arthroplasties show less bone density loss and higher serum metal ion concentrations. We expect equal functional scores, greater range of motion, fewer dislocations, fewer periprosthetic radiolucencies and increased prosthetic survival with the metal-on-metal articulation. Methods A randomized controlled trial will be conducted. Patients to be included suffer from non-inflammatory degenerative joint disease of the hip, are aged between 18 and 80 and are admitted for primary cementless unilateral total hip arthroplasty. Patients in the metal-on-metal group will receive a cementless titanium alloy acetabular component with a cobalt-chromium liner and a cobalt-chromium femoral head varying from 38 to 60 mm. Patients in the metal-on-polyethylene group will receive a cementless titanium alloy acetabular component with a polyethylene liner and a 28 mm cobalt-chromium femoral head. We will assess acetabular bone mineral density by dual energy x-ray absorptiometry (DEXA, serum ion concentrations of cobalt, chromium and titanium, self reported functional status (Oxford hip score, physician reported functional status and range of motion (Harris hip score, number of dislocations and prosthetic survival. Measurements will take place preoperatively, perioperatively, and postoperatively (6 weeks, 1 year, 5 years and 10 years. Discussion

  2. Total hip arthroplasty survival in femoral head avascular necrosis versus primary hip osteoarthritis: Case-control study with a mean 10-year follow-up after anatomical cementless metal-on-metal 28-mm replacement.

    Science.gov (United States)

    Ancelin, D; Reina, N; Cavaignac, E; Delclaux, S; Chiron, P

    2016-12-01

    Total hip arthroplasty is the most widely used procedure to treat avascular necrosis (AVN) of the femoral head. Few studies have compared the outcomes of THA in femoral head AVN and primary hip osteoarthritis. Therefore we performed a case-control study to compare THA for femoral head AVN vs. primary hip osteoarthritis in terms of: (1) prosthesis survival, (2) complication rates, (3) functional outcomes and radiographic outcomes, (4) and to determine whether specific risk factors for THA failure exist in femoral head AVN. THA survival is similar in femoral head AVN and primary hip osteoarthritis. We compared two prospective cohorts of patients who underwent THA before 65 years of age, one composed of cases with femoral head AVN and the other of controls with primary hip osteoarthritis. In both cohorts, a cementless metal-on-metal prosthesis with a 28-mm cup and an anatomical stem was used. Exclusion criteria were THA with other types of prosthesis, posttraumatic AVN, and secondary osteoarthritis. With α set at 5%, to obtain 80% power, 246 patients were required in all. Prosthesis survival was assessed based on time to major revision (defined as replacement of at least one implant fixed to bone) and time to aseptic loosening. The other evaluation criteria were complications, Postel-Merle d'Aubigné (PMA) score, and the Engh and Agora Radiographic Assessment (ARA) scores for implant osseointegration. The study included 282 patients, 149 with AVN and 133 with osteoarthritis. Mean age was 47.8±10.2 years (range, 18.5-65) and mean follow-up was 11.4±2.8 years (range, 4.5-18.3 years). The 10-year survival rates were similar in the two groups: for major revision, AVN group, 92.5% (95% confidence interval [95% CI], 90.2-94.8) and osteoarthritis group, 95.3% (95% CI, 92.9-97.7); for aseptic loosening, AVN group, 98.6% (95% CI, 97.6-98.6) and osteoarthritis, 99.2% (95% CI, 98.4-100). The AVN group had higher numbers of revision for any reason (19 vs. 6, P=0.018) and

  3. No clinical difference between large metal-on-metal total hip arthroplasty and 28-mm-head total hip arthroplasty?

    NARCIS (Netherlands)

    Zijlstra, Wierd P; van den Akker-Scheek, Inge; Zee, Mark J M; van Raay, Jos J A M

    2011-01-01

    PURPOSE: We aimed to test the claim of greater range of motion (ROM) with large femoral head metal-on-metal total hip arthroplasty. METHODS: We compared 28-mm metal-on-polyethylene (MP) total hip arthroplasty with large femoral head metal-on-metal (MM) total hip arthroplasty in a randomised clinical

  4. CT-based quantification of bone stock in large head metal-on-metal unilateral total hip replacements

    NARCIS (Netherlands)

    Boomsma, Martijn F.; Slouwerhof, Inge; van Lingen, Christiaan; Pakvis, Dean F. M.; van Dalen, Jorn A.; Edens, Mireille A.; Ettema, Harmen B.; Verheyen, Cees C. P. M.; Maas, Mario

    2016-01-01

    To explore ipsilateral and contralateral acetabular roof bone stock density in unilateral large head MoM THA whether there is a significant lower acetabular bone stock in the hip with a metal-on-metal (MoM) total hip replacement compared to the contralateral side. Second part of this study is to

  5. Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position.

    Science.gov (United States)

    Williams, Sophie; Leslie, Ian; Isaac, Graham; Jin, Zhongmin; Ingham, Eileen; Fisher, John

    2008-08-01

    Clinical studies have indicated that the angular position of the acetabular cup may influence wear in metal-on-metal total hip bearings. A high cup angle in comparison to the anatomical position may lead to the head being constrained by the superior lateral surface and rim of the cup, thus potentially changing the location of the contact zone between the head and the cup. The aim of this study was to test the hypothesis that both a steep cup angle and a lateralized position of the head can increase head contact on the superior rim of the cup, with the consequence of increased wear. Hip-joint simulator studies of metal-on-metal bearings were undertaken with cup angles of 45 degrees and 55 degrees . The femoral head was either aligned to the center of the cup or placed in a position of microlateralization. Wear was measured gravimetrically over 5 million cycles. A steep cup angle of 55 degrees showed significantly higher long-term steady-state wear than a standard cup angle of 45 degrees (p < 0.01). The difference was fivefold. Microlateralization of the head resulted in a fivefold increase in steady-state wear compared with a centralized head. The combination of a steep cup angle and a microlateralized head increased the steady-state wear rate by tenfold compared with a standard cup angle with a centralized head. These studies support the hypothesis that both an increased cup angle and a lateral head position increase wear in metal-on-metal hip prostheses.

  6. Quantitative analysis of orthopedic metal artefact reduction in 64-slice computed tomography scans in large head metal-on-metal total hip replacement, a phantom study

    NARCIS (Netherlands)

    Boomsma, Martijn F.; Warringa, Niek; Edens, Mireille A.; Mueller, Dirk; Ettema, Harmen B.; Verheyen, Cees C. P. M.; Maas, Mario

    2016-01-01

    Purpose: Quantification of the effect of O-MAR on decreasing metal artefacts caused by large head metal on metal total hip arthroplasty (MoM THA) in a dedicated phantom setup of the hip. Background: Pathological reactions of the hip capsule on Computed tomography (CT) can be difficult to diagnose

  7. Does Choice of Head Size and Neck Geometry Affect Stem Migration in Modular Large-Diameter Metal-on-Metal Total Hip Arthroplasty? A Preliminary Analysis.

    Science.gov (United States)

    Georgiou, Cs; Evangelou, Kg; Theodorou, Eg; Provatidis, Cg; Megas, Pd

    2012-01-01

    Due to their theoretical advantages, hip systems combining modular necks and large diameter femoral heads have gradually gained popularity. However, among others, concerns regarding changes in the load transfer patterns were raised. Recent stress analyses have indeed shown that the use of modular necks and big femoral heads causes significant changes in the strain distribution along the femur. Our original hypothesis was that these changes may affect early distal migration of a modular stem. We examined the effect of head diameter and neck geometry on migration at two years of follow-up in a case series of 116 patients (125 hips), who have undergone primary Metal-on-Metal total hip arthroplasty with the modular grit-blasted Profemur®E stem combined with large-diameter heads (>36 mm). We found that choice of neck geometry and head diameter has no effect on stem migration. A multivariate regression analysis including the potential confounding variables of the body mass index, bone quality, canal fill and stem positioning revealed only a negative correlation between subsidence and canal fill in midstem area. Statistical analysis, despite its limitations, did not confirm our hypothesis that choice of neck geometry and/or head diameter affects early distal migration of a modular stem. However, the importance of correct stem sizing was revealed.

  8. Modular to Monoblock: Difficulties of Detaching the M(2)a-Magnum(TM) Head Are Common in Metal-on-metal Revisions.

    Science.gov (United States)

    Mäntymäki, Heikki; Mäkelä, Keijo T; Vahlberg, Tero; Hirviniemi, Joni; Niinimäki, Tuukka

    2016-09-01

    Modern hip implants typically feature modular heads, which allow for easy exchange and removal from the femoral stem at the time of revision. However, owing to fretting, corrosion, or cold welding, the modular head may be difficult or impossible to separate from the underlying trunnion, especially if the implant has titanium interfaces between the head and the stem. We have repeatedly encountered difficulty removing the titanium sleeve adapter in the M(2)a-Magnum(TM) implant. Although the manufacturer warns about this complication and cases with these difficulties have been reported to the United States FDA, we believed this topic is important to study, because the frequency of difficulties in head removal is unknown and the complications related to this event have not been characterized. We asked: (1) Do revisions of M(2)a-Magnum(TM) implants differ from those of M(2)a-38(TM) implants in terms of ease of removal of the femoral head? (2) In cases where difficulty with M(2)a-Magnum(TM) head removal occurred, was the operative time, bleeding, risk of periprosthetic fracture, or joint infection increased compared with cases where the M(2)a-Magnum(TM) head was removed without difficulties? Between 2004 and 2014, we revised 296 THAs with metal-on-metal implants that involved M(2)a-Magnum(TM) (123) or M(2)a-38(TM) heads (88); of those, 84 were planned to include a femoral stem revision and insufficient data were available for three operations, so they were excluded from this analysis, leaving 124 THAs in the current retrospective study (70 THAs with M(2)a-Magnum(TM) and 54 THAs with M(2)a-38(TM) heads).The method of modular head removal, any difficulties removing the femoral head from the trunnion, operation time, and complications were recorded based on chart review. All the observed problems of detaching the head or taper adapter were among M(2)a-Magnum(TM) heads; there were no problems detaching the head in revisions of the M(2)a-38(TM) implant. In 29% (20 of 70) of

  9. Pseudotumour incidence, cobalt levels and clinical outcome after large head metal-on-metal and conventional metal-on-polyethylene total hip arthroplasty MID-TERM RESULTS OF A RANDOMISED CONTROLLED TRIAL

    NARCIS (Netherlands)

    van der Veen, H. C.; Reininga, I. H. F.; Zijlstra, W. P.; Boomsma, M. F.; Bulstra, S. K.; van Raay, J. J. A. M.

    2015-01-01

    We compared the incidence of pseudotumours after large head metal-on-metal (MoM) total hip arthroplasty (THA) with that after conventional metal-on-polyethylene (MoP) THA and assessed the predisposing factors to pseudotumour formation. From a previous randomised controlled trial which compared large

  10. Surgical Approach May Influence Survival of Large-Diameter Head Metal-on-Metal Total Hip Arthroplasty: A 6- to 10-Year Follow-Up Study

    Directory of Open Access Journals (Sweden)

    Chih-Chien Hu

    2017-01-01

    Full Text Available Large-diameter head (LDH metal-on-metal (MoM total hip arthroplasty (THA has lost popularity because of metal allergy or ALTRs (adverse local tissue reactions in the past decade. Whether the surgical approach may influence the survival of LDH-MoM-THA has not been reported. From 2006 to 2009, we performed 96 LDH-MoM-THAs on 80 patients using an in situ head-neck assembly technique through a modified Watson-Jones approach. With a mean follow-up of 8.4 years (range, 6.3–10.1 years, the implant survival rate was 100%. All patients were satisfied with the results and the Harris Hip Score improved from 52 points to 98 points. No ALTRs were found, but 17.7% of the 96 hips (17 adverse events experienced adverse events related to the cup, including 5 cases of outlier cup malposition, 11 cases of inadequate cup seating, and 1 acetabular fracture. The tissue tension that was improved by a muscle-sparing approach might lessen the chance of microseparation or edge-loading that is taken as the major risk for early implant failure. Further investigation of whether these LDH-MoM-THAs would fail or not would require a longer follow-up or even retrieval analysis in the future.

  11. Metal-on-metal hip joint tribology.

    Science.gov (United States)

    Dowson, D; Jin, Z M

    2006-02-01

    The basic tribological features of metal-on-metal total hip replacements have been reviewed to facilitate an understanding of the engineering science underpinning the renaissance of these hard-on-hard joints. Metal-on-polymer hip replacements operate in the boundary lubrication regime, thus leading to the design guidance to reduce the femoral head diameter as much as is feasible to minimize frictional torque and volumetric wear. This explains why the gold-standard implant of this form from the past half-century had a diameter of only 22.225 mm (7/8 in). Metal-on-metal implants can operate in the mild mixed lubrication regime in which much of the applied load is supported by elastohydrodynamic films. Correct tribological design leads to remarkably low steady state wear rates. Promotion of the most effective elastohydrodynamic films calls for the largest possible head diameters and the smallest clearances that can reasonably be adopted, consistent with fine surface finishes, good sphericity and minimal structural elastic deformation of the cup on its foundations. This guidance, which is opposite in form to that developed for metal-on-polymer joints, is equally valid for solid (monolithic) metallic heads on metallic femoral stems and surface replacement femoral shells. Laboratory measurements of friction and wear in metal-on-metal joints have confirmed their potential to achieve a very mild form of mixed lubrication. The key lies in the generation of effective elastohydrodynamic lubricating films of adequate thickness compared with the composite roughness of the head and cup. The calculation of the film thickness is by no means easy, but the full procedure is outlined and the use of an empirical formula that displays good agreement with calculations based upon the full numerical solutions is explained. The representation of the lambda ratio, lambda, embracing both film thickness and composite roughness, is described.

  12. [Ex vivo microCT analysis of possible microfractures of the femoral head during implantation of a cementless hip resurfacing femoral component].

    Science.gov (United States)

    Lerch, M; Olender, G; von der Höh, N; Thorey, F; von Lewinski, G; Meyer-Lindenberg, A; Windhagen, H; Hurschler, C

    2009-01-01

    Microfractures of the femoral head during implantation of the femoral components are suspected to be a cause of fractures at the implant/neck junction which represent a common failure mode in hip resurfacing arthroplasty. Callus formation observed in femoral head retrievals suggests the occurrence of microfractures inside the femoral head, which might be inadvertently caused by the surgeon during implantation. The aim of this biomechanical study was to analyse whether or not the implantation of a cementless femoral component hip resurfacing system causes microfractures in the femoral head. After the preparation of 20 paired human cadaveric femoral heads, the cementless femoral component ESKA Typ BS (ESKA Implants GmbH & Co., Lübeck) was implanted on 9 specimens with an impaction device that generates 4.5 kN impaction force. On 9 specimens the femoral component was implanted by hand. One head was used as a fracture model, 1 specimen served as control without manipulation. The femoral component used for impaction was equipped with hinges to enable its removal without further interfering with the bone stock. Specimens were scanned with a microCT device before and after impaction and the microCT datasets before and after impaction were compared to identify possible microfractures. Twenty strikes per hand or with the impaction device provided sufficient implant seating. Neither the macroscopic examination nor the 2-dimensional microCT analysis revealed any fractures of the femoral heads after impaction. At least macroscopically and in the 2-dimensional microCT analysis, implantation of the cementless hip resurfacing femoral component ESKA Typ BS with 4.5 kN or by hand does not seem to cause fractures of the femoral head. Georg Thieme Verlag KG Stuttgart, New York.

  13. No association between pseudotumors, high serum metal-ion levels and metal hypersensitivity in large-head metal-on-metal total hip arthroplasty at 5-7-year follow-up

    DEFF Research Database (Denmark)

    Hjorth, Mette Holm; Stilling, Maiken; Soballe, Kjeld

    2015-01-01

    -ion concentrations were measured, metal allergy and atopic dermatitis were evaluated, and the questionnaires of the Oxford Hip Score (OHS), Harris Hip Score (HHS) and the Short-Form Health Survey (SF-36) were completed. RESULTS: Pseudotumors were found in eight patients, but they were asymptomatic and their serum...... pseudotumor formation, serum metal-ion levels, metal patch test reactivity, and atopic dermatitis. However, clinicians should be aware of asymptomatic pseudotumors, and we advise further exploration into the mechanisms involved in the pathogenesis of pseudotumors.......OBJECTIVE: The relationship between metal wear debris, pseudotumor formation and metal hypersensitivity is complex and not completely understood. The purpose of this study was to assess the prevalence of pseudotumor formation in a consecutive series of metal-on-metal (MoM) total hip arthroplasty...

  14. Metal-on-Metal Total Hip Resurfacing Arthroplasty

    Science.gov (United States)

    2006-01-01

    Executive Summary Objective The objective of this review was to assess the safety and effectiveness of metal on metal (MOM) hip resurfacing arthroplasty for young patients compared with that of total hip replacement (THR) in the same population. Clinical Need Total hip replacement has proved to be very effective for late middle-aged and elderly patients with severe degenerative diseases of the hips. As indications for THR began to include younger patients and those with a more active life style, the longevity of the implant became a concern. Evidence suggests that these patients experience relatively higher rates of early implant failure and the need for revision. The Swedish hip registry, for example, has demonstrated a survival rate in excess of 80% at 20 years for those aged over 65 years, whereas this figure was 33% by 16 years in those aged under 55 years. Hip resurfacing arthroplasty is a bone-conserving alternative to THR that restores normal joint biomechanics and load transfer. The technique has been used around the world for more than 10 years, specifically in the United Kingdom and other European countries. The Technology Metal-on-metal hip resurfacing arthroplasty is an alternative procedure to conventional THR in younger patients. Hip resurfacing arthroplasty is less invasive than THR and addresses the problem of preserving femoral bone stock at the initial operation. This means that future hip revisions are possible with THR if the initial MOM arthroplasty becomes less effective with time in these younger patients. The procedure involves the removal and replacement of the surface of the femoral head with a hollow metal hemisphere, which fits into a metal acetabular cup. Hip resurfacing arthroplasty is a technically more demanding procedure than is conventional THR. In hip resurfacing, the femoral head is retained, which makes it much more difficult to access the acetabular cup. However, hip resurfacing arthroplasty has several advantages over a

  15. Abductor dysfunction and related sciatic nerve palsy, a new complication of metal-on-metal arthroplasty.

    Science.gov (United States)

    Beaver, Walter B; Fehring, Thomas K

    2012-08-01

    The optimal bearing for use in young patients with hip arthritis remains elusive. Current options include metal-on-cross-linked polyethylene, ceramic-on-cross-linked polyethylene, ceramic on ceramic, and metal on metal. Each of these bearing couples has advantages and disadvantages. Metal-on-metal designs allow the use of large heads that decrease impingement and improve stability. This fact has made this bearing an attractive option for surgeons and patients alike. This case report will illustrate a severe adverse reaction to metal debris with necrosis of soft tissues and subsequent damage to the sciatic nerve. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. The tribology of metal-on-metal total hip replacements.

    Science.gov (United States)

    Scholes, S C; Unsworth, A

    2006-02-01

    Total hip surgery is an effective way of alleviating the pain and discomfort caused by diseased or damaged joints. However, in the majority of cases, these joints have a finite life. The main reason for failure is osteolysis (bone resorption). It is well documented that an important cause of osteolysis, and therefore the subsequent loosening and failure of conventional metal- or ceramic-on-ultra-high molecular weight polyethylene joints, is the body's immunological response to the polyethylene wear particles. To avoid this, interest has been renewed in metal-on-metal joints. The intention of this paper is to review the studies that have taken place within different laboratories to determine the tribological performance of new-generation metal-on-metal total hip replacements. These types of joint offer a potential solution to enhance the longevity of prosthetic hip systems; however, problems may arise owing to the effects of metal ion release, which are, as yet, not fully understood.

  17. Metal-on-Metal Total Hip Resurfacing Arthroplasty: An Evidence-Based Analysis.

    Science.gov (United States)

    2006-01-01

    The objective of this review was to assess the safety and effectiveness of metal on metal (MOM) hip resurfacing arthroplasty for young patients compared with that of total hip replacement (THR) in the same population. Total hip replacement has proved to be very effective for late middle-aged and elderly patients with severe degenerative diseases of the hips. As indications for THR began to include younger patients and those with a more active life style, the longevity of the implant became a concern. Evidence suggests that these patients experience relatively higher rates of early implant failure and the need for revision. The Swedish hip registry, for example, has demonstrated a survival rate in excess of 80% at 20 years for those aged over 65 years, whereas this figure was 33% by 16 years in those aged under 55 years. Hip resurfacing arthroplasty is a bone-conserving alternative to THR that restores normal joint biomechanics and load transfer. The technique has been used around the world for more than 10 years, specifically in the United Kingdom and other European countries. Metal-on-metal hip resurfacing arthroplasty is an alternative procedure to conventional THR in younger patients. Hip resurfacing arthroplasty is less invasive than THR and addresses the problem of preserving femoral bone stock at the initial operation. This means that future hip revisions are possible with THR if the initial MOM arthroplasty becomes less effective with time in these younger patients. The procedure involves the removal and replacement of the surface of the femoral head with a hollow metal hemisphere, which fits into a metal acetabular cup. Hip resurfacing arthroplasty is a technically more demanding procedure than is conventional THR. In hip resurfacing, the femoral head is retained, which makes it much more difficult to access the acetabular cup. However, hip resurfacing arthroplasty has several advantages over a conventional THR with a small (28 mm) ball. First, the large

  18. Fatal Cobalt Toxicity after a Non-Metal-on-Metal Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Rinne M. Peters

    2017-01-01

    Full Text Available This case illustrates the potential for systemic cobalt toxicity in non-metal-on-metal bearings and its potentially devastating consequences. We present a 71-year-old male with grinding sensations in his right hip following ceramic-on-ceramic total hip arthroplasty (THA. After diagnosing a fractured ceramic liner, the hip prosthesis was revised into a metal-on-polyethylene bearing. At one year postoperatively, X-rays and MARS-MRI showed a fixed reversed hybrid THA, with periarticular densities, flattening of the femoral head component, and a pattern of periarticular metal wear debris and pseudotumor formation. Before revision could take place, the patient was admitted with the clinical picture of systemic cobalt toxicity, supported by excessively high serum cobalt and chromium levels, and ultimately died. At autopsy dilated cardiomyopathy as cause of death was hypothesized. A third body wear reaction between ceramic remnants and the metal femoral head very likely led to excessive metal wear, which contributed systemic cobalt toxicity leading to neurotoxicity and heart failure. This case emphasizes that fractured ceramic-on-ceramic bearings should be revised to ceramic-on-ceramic or ceramic-on-polyethylene bearings, but not to metal-on-polyethylene bearings. We aim to increase awareness among orthopedic surgeons for clinical clues for systemic cobalt intoxication, even when there is no metal-on-metal bearing surface.

  19. The possibilities of magnetic resonance imaging in the diagnostics of complications after metal-on-metal hip arthroplasty

    Directory of Open Access Journals (Sweden)

    A. A. Vergay

    2013-01-01

    Full Text Available Objective: to find adverse periprosthetic local tissue reactions after metal-on-metal hip arthroplasty with ASR XL heads. Material and methods: 119 patients with 134 ASR XL head - Corail prostheses were treated in 2007-2009. The results were studied in 94 cases (105 prostheses - 84%. Average follow-up time consisted 62 ± 3 months. MRI was performed in 12 patients (13 hips who had clinical nonsatisfaction. Obtained data were compared with 21 MRI (24 hips of controlled group with good and perfect clinical results. Results. We found variations of normal periprosthetic tissue condition. Adverse reactions were identified in 10 cases. To improve the quality of pictures we developed special MRI adjustments and regimes of work. Conclusion: MRI diagnostics is indicated for the patients with metal-on-metal total hip arthroplasty in order to identify adverse local tissue reactions. The improvement of picture quality needs special adjustment of MRI equipment.

  20. Early results of metal on metal articulation total hip arthroplasty in young patients.

    Science.gov (United States)

    Mohamad, J A; Kwan, M K; Merican, A M; Abbas, A A; Kamari, Z H; Hisa, M K; Ismail, Z; Idrus, R M

    2004-12-01

    We report our early experience of 20 cases of metal on metal articulation total hip arthroplasty in 19 young patients. Avascular necrosis of the femoral head (63%) was the commonest diagnosis for patients undergoing this procedure, followed by osteoarthritis (21%). In general, most of the patients were young and physically active with an average age of 43.1 years (range, 25 to 58 years). The average follow-up period was 18 months (range, 7 to 46 months). The mean total Harris Hip Score preoperatively and at final follow-up was 31 points and 89 points respectively. The mean total Pain Score improved from an average of 11.5 to 41.1 points at final follow-up. Sixteen (84%) of the patients had a good to excellent hip score. There was one dislocation, which stabilized after reduction and conservative management. One case of early infection underwent a two-staged revision.

  1. Long-term retrospective study on the placement of the cementless acetabular cup and clinical outcomes in patients undergoing femoral head autografting for hip dysplasia and total hip arthroplasty.

    Science.gov (United States)

    Ozden, Vahit Emre; Dikmen, Goksel; Beksac, Burak; Tozun, Ismail Remzi

    2018-05-01

    Placement of acetabular cup in the dysplastic hip is a challenging procedure. Using bulk femoral head autograft to increase the bony coverage of the cup is one of the techniques, which have been described. The impact of cup position on cup and autograft survival is a controversial issue. We aimed to determine whether the position of cementless acetabular cup used in conjunction with femoral head autograft in dysplastic hips affected the autograft-host incorporation with its final radiographic appearance and the cup survivorship into the second decade. Thirty-eight dysplastic hips with varying Crowe types in 31 patients (30 women and one man) were included. The mean age was 47 years (range, 29-64 years) and the mean follow-up was 20.3 years (range, 14.8-25.9 years). The initial postoperative and final radiographs were evaluated. The survival rate of the cups was analysed using Kaplan-Meier statistics and the log-rank test. Multivariate analysis was used to evaluate the effect of variables (Crowe type, radiographic initial host bone coverage over the cup and position of the cup) on survivorship. The acetabular cups were positioned anatomical in 27/38 hips according to Ranawat measurement technique. Trabecular bridging at graft-host interface was seen in all cases at an average 22.1 months. Neither acetabular cup position nor initial host bone coverage over acetabular cup less than 50% had any significant effect on either cup survival or final radiographic appearance of the graft. The 20-year cup survival rate without aseptic revision was 66% (95 CI, 52%-84%). No revision was performed due to graft resorption. Twenty-year survival rate of the cementless cup combination with femoral head autograft showed no significant differences whether it was placed at high or anatomic hip centre. The final radiographic appearance of the autograft was not affected from either the cup location or the initial radiographic horizontal host bone coverage. Copyright © 2018 The Japanese

  2. High Re-Operation Rates Using Conserve Metal-On-Metal Total Hip Articulations

    DEFF Research Database (Denmark)

    Mogensen, S L; Jakobsen, Thomas; Christoffersen, Hardy

    2016-01-01

    INTRODUCTION: Metal-on-metal hip articulations have been intensely debated after reports of adverse reactions and high failure rates. The aim of this study was to retrospectively evaluate the implant of a metal-on.metal total hip articulation (MOM THA) from a single manufacture in a two-center st......INTRODUCTION: Metal-on-metal hip articulations have been intensely debated after reports of adverse reactions and high failure rates. The aim of this study was to retrospectively evaluate the implant of a metal-on.metal total hip articulation (MOM THA) from a single manufacture in a two...

  3. Metal-on-metal hip resurfacings. A radiological perspective

    International Nuclear Information System (INIS)

    Chen, Zhongbo; Pandit, Hemant; Taylor, Adrian; Gill, Harinderjit; Murray, David; Ostlere, Simon

    2011-01-01

    It is important to be aware of the various complications related to resurfacing arthroplasty of the hip (RSA) and the spectrum of findings that may be encountered on imaging. The bone conserving metal-on-metal (MOM) hip resurfacing has become increasingly popular over the last ten years, especially in young and active patients. Initial reports have been encouraging, but long-term outcome is still unknown. Early post operative complications are rare and have been well documented in the literature. Medium and long term complications are less well understood. A rare but important problem seen at this stage is the appearance of a cystic or solid periarticular reactive mass, which occurs predominately in women and usually affects both hips when seen in patients with bilateral RSAs. The following imaging findings are illustrated and their significance discussed; Uncomplicated hip resurfacing arthroplasty, radiolucency around the femoral peg, femoral neck fracture, loosening and infection, suboptimal component position, femoral notching, dislocation, heterotopic ossification, femoral neck thinning and reactive masses. The radiologist should be aware of the normal radiographic appearances and the variety of complications that may occur following RSA and should recommend ultrasound or MRI in patients with an unexplained symptomatic hip and normal radiographs. (orig.)

  4. Comparative study of material loss at the taper interface in retrieved metal-on-polyethylene and metal-on-metal femoral components from a single manufacturer.

    Science.gov (United States)

    Bills, Paul; Racasan, Radu; Bhattacharya, Saugatta; Blunt, Liam; Isaac, Graham

    2017-08-01

    There have been a number of reports on the occurrence of taper corrosion and/or fretting and some have speculated on a link to the occurrence of adverse local tissue reaction specifically in relation to total hip replacement which have a metal-on-metal bearing. As such a study was carried out to compare the magnitude of material loss at the taper in a series of retrieved femoral heads used in metal-on-polyethylene bearings with that in a series of retrieved heads used in metal-on-metal bearings. A total of 36 metal-on-polyethylene and 21 metal-on-metal femoral components were included in the study all of which were received from a customer complaint database. Furthermore, a total of nine as-manufactured femoral components were included to provide a baseline for characterisation. All taper surfaces were assessed using an established corrosion scoring method and measurements were taken of the female taper surface using a contact profilometry. In the case of metal-on-metal components, the bearing wear was also assessed using coordinate metrology to determine whether or not there was a relationship between bearing and taper material loss in these cases. The study found that in this cohort the median value of metal-on-polyethylene taper loss was 1.25 mm 3 with the consequent median value for metal-on-metal taper loss being 1.75 mm 3 . This study also suggests that manufacturing form can result in an apparent loss of material from the taper surface determined to have a median value of 0.59 mm 3 . Therefore, it is clear that form variability is a significant confounding factor in the measurement of material loss from the tapers of femoral heads retrieved following revision surgery.

  5. Edge loading in metal-on-metal hips: low clearance is a new risk factor.

    Science.gov (United States)

    Underwood, Richard J; Zografos, Angelos; Sayles, Ritchie S; Hart, Alister; Cann, Philippa

    2012-03-01

    The revision rate of large head metal-on-metal and resurfacing hips are significantly higher than conventional total hip replacements. The revision of these components has been linked to high wear caused by edge loading; which occurs when the head-cup contact patch extends over the cup rim. There are two current explanations for this; first, there is loss of entrainment of synovial fluid resulting in breakdown of the lubricating film and second, edge loading results in a large local increase in contact pressure and consequent film thickness reduction at the cup rim, which causes an increase in wear. This paper develops a method to calculate the distance between the joint reaction force vector and the cup rim--the contact patch centre to rim (CPCR) distance. However, the critical distance for the risk of edge loading is the distance from the contact patch edge to rim (CPER) distance. An analysis of explanted hip components, divided into edge worn and non-edge-worn components showed that there was no statistical difference in CPCR values, but the CPER value was significantly lower for edge worn hips. Low clearance hips, which have a more conformal contact, have a larger diameter contact patch and thus are more at risk of edge loading for similarly positioned hips.

  6. Inflammatory pseudotumor causing deep vein thrombosis after metal-on-metal hip resurfacing arthroplasty.

    LENUS (Irish Health Repository)

    Memon, Adeel Rasool

    2013-01-01

    Metal-on-metal hip resurfacings have recently been associated with a variety of complications resulting from adverse reaction to metal debris. We report a case of extensive soft tissue necrosis associated with a huge pelvic mass causing extensive deep vein thrombosis of the lower limb secondary to mechanical compression of the iliac vein. This is a rare and unusual cause of deep vein thrombosis after metal-on-metal hip resurfacing arthroplasty.

  7. Cementless Hydroxyapatite Coated Hip Prostheses

    Science.gov (United States)

    Herrera, Antonio; Mateo, Jesús; Gil-Albarova, Jorge; Lobo-Escolar, Antonio; Ibarz, Elena; Gabarre, Sergio; Más, Yolanda

    2015-01-01

    More than twenty years ago, hydroxyapatite (HA), calcium phosphate ceramics, was introduced as a coating for cementless hip prostheses. The choice of this ceramic is due to its composition being similar to organic apatite bone crystals. This ceramic is biocompatible, bioactive, and osteoconductive. These qualities facilitate the primary stability and osseointegration of implants. Our surgical experience includes the implantation of more than 4,000 cementless hydroxyapatite coated hip prostheses since 1990. The models implanted are coated with HA in the acetabulum and in the metaphyseal area of the stem. The results corresponding to survival and stability of implants were very satisfactory in the long-term. From our experience, HA-coated hip implants are a reliable alternative which can achieve long term survival, provided that certain requirements are met: good design selection, sound choice of bearing surfaces based on patient life expectancy, meticulous surgical technique, and indications based on adequate bone quality. PMID:25802848

  8. Cementless Hydroxyapatite Coated Hip Prostheses

    Directory of Open Access Journals (Sweden)

    Antonio Herrera

    2015-01-01

    Full Text Available More than twenty years ago, hydroxyapatite (HA, calcium phosphate ceramics, was introduced as a coating for cementless hip prostheses. The choice of this ceramic is due to its composition being similar to organic apatite bone crystals. This ceramic is biocompatible, bioactive, and osteoconductive. These qualities facilitate the primary stability and osseointegration of implants. Our surgical experience includes the implantation of more than 4,000 cementless hydroxyapatite coated hip prostheses since 1990. The models implanted are coated with HA in the acetabulum and in the metaphyseal area of the stem. The results corresponding to survival and stability of implants were very satisfactory in the long-term. From our experience, HA-coated hip implants are a reliable alternative which can achieve long term survival, provided that certain requirements are met: good design selection, sound choice of bearing surfaces based on patient life expectancy, meticulous surgical technique, and indications based on adequate bone quality.

  9. Development and first validation of a simplified CT-based classification system of soft tissue changes in large-head metal-on-metal total hip replacement: intra- and interrater reliability and association with revision rates in a uniform cohort of 664 arthroplasties

    International Nuclear Information System (INIS)

    Boomsma, Martijn F.; Warringa, Niek; Edens, Mireille A.; Lingen, Christiaan P. van; Ettema, Harmen B.; Verheyen, Cees C.P.M.; Maas, Mario

    2015-01-01

    After implantation of a metal-on-metal total hip arthroplasty (MoM THA), a large incidence of pseudotumor formation has been described recently. Several centers have invited patients for follow-up in order to screen for pseudotumor formation. The spectrum of abnormalities found by CT in MoM THA patients can be unfamiliar to radiologists and orthopedic surgeons. Previously, a CT five-point grading scale has been published. In this paper, a simplification into a three-point classification system gives insight in the morphological distinction of abnormalities of the postoperative hip capsule in MoM implants in relation to the decision for revision. The reliability of this simplified classification regarding intra- and interrater reliability and its association with revision rate is investigated and discussed. All patients who underwent MoM THA in our hospital were invited for screening. Various clinical measures and CT scan were obtained in a cross-sectional fashion. A decision on revision surgery was made shortly after screening. CT scans were read in 582 patients, of which 82 patients were treated bilaterally. CT scans were independently single read by two board-certified radiologists and classified into categories I-V. In a second meeting, consensus was obtained. Categories were subsequently rubricated in class A (categories I and II), B (category III), and C (categories IV and V). Intra- and inter-radiologist agreement on MoM pathology was assessed by means of the weighted Cohen's kappa. Categorical data were presented as n (%), and tested by means of Fisher's exact test. Continuous data were presented as median (min-max) and tested by means of Mann-Whitney U test (two group comparison) or Kruskal-Wallis test (three group comparison). Logistic regression analysis was performed in order to study independence of CT class for association with revision surgery. Univariate statistically significant variables were entered in a multiple model. All statistical

  10. Development and first validation of a simplified CT-based classification system of soft tissue changes in large-head metal-on-metal total hip replacement: intra- and interrater reliability and association with revision rates in a uniform cohort of 664 arthroplasties

    Energy Technology Data Exchange (ETDEWEB)

    Boomsma, Martijn F.; Warringa, Niek [Isala Hospital, Department of Radiology, Zwolle (Netherlands); Edens, Mireille A. [Isala Hospital, Department of Innovation and Science, Zwolle (Netherlands); Lingen, Christiaan P. van; Ettema, Harmen B.; Verheyen, Cees C.P.M. [Isala Hospital, Department of Orthopaedics, Zwolle (Netherlands); Maas, Mario [AMC, Department of Radiology, Amsterdam (Netherlands)

    2015-08-15

    After implantation of a metal-on-metal total hip arthroplasty (MoM THA), a large incidence of pseudotumor formation has been described recently. Several centers have invited patients for follow-up in order to screen for pseudotumor formation. The spectrum of abnormalities found by CT in MoM THA patients can be unfamiliar to radiologists and orthopedic surgeons. Previously, a CT five-point grading scale has been published. In this paper, a simplification into a three-point classification system gives insight in the morphological distinction of abnormalities of the postoperative hip capsule in MoM implants in relation to the decision for revision. The reliability of this simplified classification regarding intra- and interrater reliability and its association with revision rate is investigated and discussed. All patients who underwent MoM THA in our hospital were invited for screening. Various clinical measures and CT scan were obtained in a cross-sectional fashion. A decision on revision surgery was made shortly after screening. CT scans were read in 582 patients, of which 82 patients were treated bilaterally. CT scans were independently single read by two board-certified radiologists and classified into categories I-V. In a second meeting, consensus was obtained. Categories were subsequently rubricated in class A (categories I and II), B (category III), and C (categories IV and V). Intra- and inter-radiologist agreement on MoM pathology was assessed by means of the weighted Cohen's kappa. Categorical data were presented as n (%), and tested by means of Fisher's exact test. Continuous data were presented as median (min-max) and tested by means of Mann-Whitney U test (two group comparison) or Kruskal-Wallis test (three group comparison). Logistic regression analysis was performed in order to study independence of CT class for association with revision surgery. Univariate statistically significant variables were entered in a multiple model. All statistical

  11. The acting wear mechanisms on metal-on-metal hip joint bearings: in-vitro results

    NARCIS (Netherlands)

    Wimmer, M.A.; Loos, J.; Nassutt, R.; Heitkemper, M.; Fischer, A.

    2001-01-01

    Metal-on-metal (MOM) hip joint bearings are currently under discussion as alternatives to metal-on-polymer (MOP) bearings. Some criteria under scrutiny are the wear resistance, the influence of wear particles on the surrounding tissue, as well as the frictional torque. In order to understand and

  12. The effect of the metal-on-metal hip controversy on internet search activity.

    LENUS (Irish Health Repository)

    Phelan, Nigel

    2014-01-04

    The recall of the articular surface replacement (ASR) hip prosthesis in 2010 represents one of the most controversial areas in orthopaedic surgery in recent years. The aim of this study was to compare the impact of the metal-on-metal hip controversy on Internet search activity in four different regions and determine whether the number of related news reports affected Internet search activity. The Google Trends, Keywords and News applications were used to record the number of news articles and Internet search activity for the terms "hip recall", "metal-on-metal hip" and "ASR hip" from October 2009 to October 2012 in the USA, the UK, Australia and Ireland. There was a large increase in search activity following the official recall in August 2010 in all countries. There was significantly greater search activity after the recall in Ireland compared with the UK for the search term "hip recall" (P = 0.004). For the term "metal-on-metal hip", the UK had significantly more search activity (P = 0.0009). There was a positive correlation between the number of news stories in UK and Ireland with Internet search activity but not in the USA or Australia. Differences between countries affected by the same recall highlight the complex effects of the media on public awareness. The data demonstrates a window of opportunity prior to the official recall for the development of an awareness campaign to provide patients with accurate information.

  13. Infection or metal hypersensitivity? The diagnostic challenge of failure in metal-on-metal bearings.

    LENUS (Irish Health Repository)

    Galbraith, John G

    2011-04-01

    The use of second generation metal-on-metal hip articulations has gained favour in the past few years. A hypersensitivity reaction to the metal-on-metal bearing, although rare, is a reported complication and is a novel mode of failure of these implants. Differentiating failure secondary to infection from failure secondary to metal hypersensitivity represents a significant diagnostic challenge. A retrospective review of all cases of hip arthroplasty using metal-on-metal bearings over a 5-year period at a tertiary referral centre identified 3 cases of failure secondary to metal hypersensitivity. Clinical presentation, serological markers, radiological imaging and histological analysis of all cases identified were evaluated. Histological analysis of periprosthetic tissue in all 3 cases identified characteristic features such as perivascular lymphocytic aggregates and chronic inflammation consistent with aseptic lymphocytic vasculitis-associated lesions (ALVAL). This study highlights that failure secondary to metal hypersensitivity must be considered in patients presenting with the reappearance of persistent pain, marked joint effusion, and the development of early osteolysis in the absence of infection.

  14. Effect of carbon ion implantation on the tribology of metal-on-metal bearings for artificial joints

    Directory of Open Access Journals (Sweden)

    Koseki H

    2017-05-01

    Full Text Available Hironobu Koseki,1 Masato Tomita,2 Akihiko Yonekura,2 Takashi Higuchi,1 Sinya Sunagawa,2 Koumei Baba,3,4 Makoto Osaki2 1Department of Locomotive Rehabilitation Science, Unit of Rehabilitation Sciences, 2Department of Orthopedic Surgery, Nagasaki University Graduate School of Biomedical Sciences, Sakamoto, Nagasaki, Japan; 3Industrial Technology Center of Nagasaki, Ikeda, Omura, Nagasaki, Japan; 4Affiliated Division, Nagasaki University School of Engineering, Bunkyo, Nagasaki, Japan Abstract: Metal-on-metal (MoM bearings have become popular due to a major advantage over metal-on-polymer bearings for total hip arthroplasty in that the larger femoral head and hydrodynamic lubrication of the former reduce the rate of wear. However, concerns remain regarding adverse reactions to metal debris including metallosis caused by metal wear generated at the taper-head interface and another modular junction. Our group has hypothesized that carbon ion implantation (CII may improve metal wear properties. The purpose of this study was to investigate the wear properties and friction coefficients of CII surfaces with an aim to ultimately apply these surfaces to MoM bearings in artificial joints. CII was applied to cobalt-chromium-molybdenum (Co-Cr-Mo alloy substrates by plasma source ion implantation. The substrates were characterized using scanning electron microscopy and a 3D measuring laser microscope. Sliding contact tests were performed with a simple geometry pin-on-plate wear tester at a load of 2.5 N, a calculated contact pressure of 38.5 MPa (max: 57.8 MPa, a reciprocating velocity of 30 mm/s, a stroke length of 60 mm, and a reciprocating cycle count of 172,800 cycles. The surfaces of the CII substrates were generally featureless with a smooth surface topography at the same level as untreated Co-Cr-Mo alloy. Compared to the untreated Co-Cr-Mo alloy, the CII-treated bearings had lower friction coefficients, higher resistance to catastrophic damage, and

  15. Revision rates for metal-on-metal hip resurfacing and metal-on-metal total hip arthroplasty – a systematic review

    DEFF Research Database (Denmark)

    Ras Sørensen, Sofie-amalie L.; Jørgensen, Henrik L.; Sporing, Sune L.

    2016-01-01

    Purpose To compare revision rates of metal-on-metal (MoM) hip resurfacing (HRS) and MoM total hip arthroplasty (THA), as well as the primary causes for revisions. Methods The PubMed database was queried for potentially relevant articles addressing MoMTHA and MoMHRS, a total of 51 articles were....... The odds ratio was 1.25 (1.03:1.53) 95% CI (p = 0.03) (MoMHRS vs. MoMTHA). The studies of hip prostheses were separated into 2 categories of short- and long-term (more or less than 5 years). Short-term revision rate for MoMTHA was 4.5% after 4.8 years, and for MoMHRS 4.0% after 4.2 years. The odds ratio...

  16. Effect of carbon ion implantation on the tribology of metal-on-metal bearings for artificial joints.

    Science.gov (United States)

    Koseki, Hironobu; Tomita, Masato; Yonekura, Akihiko; Higuchi, Takashi; Sunagawa, Sinya; Baba, Koumei; Osaki, Makoto

    2017-01-01

    Metal-on-metal (MoM) bearings have become popular due to a major advantage over metal-on-polymer bearings for total hip arthroplasty in that the larger femoral head and hydrodynamic lubrication of the former reduce the rate of wear. However, concerns remain regarding adverse reactions to metal debris including metallosis caused by metal wear generated at the taper-head interface and another modular junction. Our group has hypothesized that carbon ion implantation (CII) may improve metal wear properties. The purpose of this study was to investigate the wear properties and friction coefficients of CII surfaces with an aim to ultimately apply these surfaces to MoM bearings in artificial joints. CII was applied to cobalt-chromium-molybdenum (Co-Cr-Mo) alloy substrates by plasma source ion implantation. The substrates were characterized using scanning electron microscopy and a 3D measuring laser microscope. Sliding contact tests were performed with a simple geometry pin-on-plate wear tester at a load of 2.5 N, a calculated contact pressure of 38.5 MPa (max: 57.8 MPa), a reciprocating velocity of 30 mm/s, a stroke length of 60 mm, and a reciprocating cycle count of 172,800 cycles. The surfaces of the CII substrates were generally featureless with a smooth surface topography at the same level as untreated Co-Cr-Mo alloy. Compared to the untreated Co-Cr-Mo alloy, the CII-treated bearings had lower friction coefficients, higher resistance to catastrophic damage, and prevented the adhesion of wear debris. The results of this study suggest that the CII surface stabilizes the wear status due to the low friction coefficient and low infiltration of partner materials, and these properties also prevent the adhesion of wear debris and inhibit excessive wear. Carbon is considered to be biologically inert; therefore, CII is anticipated to be applicable to the bearing surfaces of MoM prostheses.

  17. [Technology of cementless hip endoprosthetics].

    Science.gov (United States)

    Ungethüm, M; Blömer, W

    1987-06-01

    The success achieved with non-cemented hip arthroplasty depends mainly on the stability of the fixation, the quality of the stabilizing bone being just as important as favourable biomechanical conditions. The results of the intensive research and development with respect to the particular features of a non-cemented hip endoprosthesis can be divided into the following basic categories: Biomechanical aspects with special reference to bone related to the design of the prosthesis; material characteristics, such as fatigue strength, tribology, corrosion resistance, and biocompatibility; and development of new materials and coatings to permit direct bonding of implant and bone. With regard to the stem of hip prostheses, the different design parameters of various types are examined to determine their typical design characteristics, such as bearing surface of the collar, geometry of cross section, anatomically adapted shaping, and surface of the implant forming the contact with the bone. The latter can be divided into macroprofiles and macro- and micro-porous coated surfaces. On the other hand, the methods of cementless fixation of acetabular cups can be primarily divided into conical and spherical screw fixation and pegged fixation with additional macroprofiles of porous surfaces. In a separate study of the biomechanical aspects of screwed sockets, the special importance of socket shape and thread geometry are presented with reference to primary stability and long-term fixation of prostheses.

  18. Breast milk metal ion levels in a young and active patient with a metal-on-metal hip prosthesis.

    Science.gov (United States)

    Nelis, Raymond; de Waal Malefijt, Jan; Gosens, Taco

    2013-01-01

    Metal-on-metal resurfacing arthroplasty of the hip has been used increasingly over the last 10 years in younger active patients. The dissolution of the metal wear particles results in measurable increases in cobalt and chromium ions in the serum and urine of patients with a metal-on-metal bearing. We measured the cobalt, chromium, and molybdenum ion levels in urine; serum; and breast milk in a young and active patient with a metal-on-metal hip prosthesis after a pathologic fracture of the femoral neck. Metal-on-metal hip prosthesis leads to increasing levels of molybdenum in breast milk in the short-term follow-up. There are no increasing levels of chromium and cobalt ions in breast milk. Besides the already known elevated concentrations in serum of chromium and cobalt after implantation of a metal-on-metal hip prosthesis, we found no increasing levels of chromium and cobalt in urine. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Bone remodeling around cementless tantalum cups

    NARCIS (Netherlands)

    Grillo, J. -C.; Flecher, X.; Bouvenot, J.; Argenson, J. -N.

    2008-01-01

    Purpose of the study.-Most studies have reported a significant decrease in periacetabular bone stock one year after implantation of a cementless cup. The purpose of this work was to study the bone-implant interface of the tantalum cup using plain X-rays and dual-energy X-ray absorptiometry (DEXA).

  20. Unusual presentation of failed metal-on-metal total hip arthroplasty with features of neoplastic process

    Directory of Open Access Journals (Sweden)

    Robert P. Runner, MD

    2017-06-01

    Full Text Available Metal-on-metal (MoM total hip arthroplasty (THA is associated with increased incidence of failure from metallosis, adverse tissue reactions, and the formation of pseudotumors. This case highlights a 53-year-old female with an enlarging painful thigh mass 12 years status post MoM THA. Radiographs and advanced imaging revealed an atypical mass with cortical bone destruction and spiculation, concerning for periprosthetic malignancy. Open frozen section biopsy was performed before undergoing revision THA in a single episode of care. This case illustrates that massive pseudotumors can be locally aggressive causing significant femoral bone destruction and may mimic malignancy. It is important that orthopaedic surgeons, radiologists and pathologists understand the relative infrequency of periprosthetic malignancy in MoM THA to mitigate patient concerns, misdiagnosis, and allow for an evidence based discussion when treating massive pseudotumors.

  1. Prediction of contact mechanics in metal-on-metal Total Hip Replacement for parametrically comprehensive designs and loads.

    Science.gov (United States)

    Donaldson, Finn E; Nyman, Edward; Coburn, James C

    2015-07-16

    Manufacturers and investigators of Total Hip Replacement (THR) bearings require tools to predict the contact mechanics resulting from diverse design and loading parameters. This study provides contact mechanics solutions for metal-on-metal (MoM) bearings that encompass the current design space and could aid pre-clinical design optimization and evaluation. Stochastic finite element (FE) simulation was used to calculate the head-on-cup contact mechanics for five thousand combinations of design and loading parameters. FE results were used to train a Random Forest (RF) surrogate model to rapidly predict the contact patch dimensions, contact area, pressures and plastic deformations for arbitrary designs and loading. In addition to widely observed polar and edge contact, FE results included ring-polar, asymmetric-polar, and transitional categories which have previously received limited attention. Combinations of design and load parameters associated with each contact category were identified. Polar contact pressures were predicted in the range of 0-200 MPa with no permanent deformation. Edge loading (with subluxation) was associated with pressures greater than 500 MPa and induced permanent deformation in 83% of cases. Transitional-edge contact (with little subluxation) was associated with intermediate pressures and permanent deformation in most cases, indicating that, even with ideal anatomical alignment, bearings may face extreme wear challenges. Surrogate models were able to accurately predict contact mechanics 18,000 times faster than FE analyses. The developed surrogate models enable rapid prediction of MoM bearing contact mechanics across the most comprehensive range of loading and designs to date, and may be useful to those performing bearing design optimization or evaluation. Published by Elsevier Ltd.

  2. Chromium and cobalt ion concentrations in blood and serum following various types of metal-on-metal hip arthroplasties

    DEFF Research Database (Denmark)

    Jantzen, Christopher; Jørgensen, Henrik L; Duus, Benn R

    2013-01-01

    Widely different metal ion concentrations in blood and serum have been reported with metal-on-metal (MoM) implants. We reviewed the literature on blood and serum ion concentrations of chromium (Cr) and cobalt (Co) following various MoM hip arthroplasties.......Widely different metal ion concentrations in blood and serum have been reported with metal-on-metal (MoM) implants. We reviewed the literature on blood and serum ion concentrations of chromium (Cr) and cobalt (Co) following various MoM hip arthroplasties....

  3. Heavy reading in heavy metal : Unraveling the mystery of hip tissue in metal on metal total hip arthroplasty

    NARCIS (Netherlands)

    Boomsma, M.F.

    2017-01-01

    In this thesis, we investigated the use of computer tomography (CT) for the screening of patients with a metal-on-metal (MoM) hip prosthesis in two patient cohorts. With a self-established CT grading scale, we have shown that CT is a reliable method for the diagnosis of postoperative pathological

  4. Management of metal-on-metal hip implant patients: Who, when and how to revise?

    Science.gov (United States)

    Berber, Reshid; Skinner, John A; Hart, Alister J

    2016-05-18

    The debate on how best to manage patients with metal-on-metal (MOM) hip implants continues. With over 1 million patients affected worldwide, the impact is far reaching. The majority of the aggressive failures of MOM hip implants have been dealt with by revision hip surgery, leaving patients with a much more indolent pattern of failure of devices that have been in situ for more than 10 years. The longer-term outcome for such patients remains unknown, and much debate exists on how best to manage these patients. Regulatory guidance is available but remains open to interpretation due to the lack of current evidence and long-term studies. Metal ion thresholds for concern have been suggested at 7 ppb for hip resurfacing arthroplasty and below this level for large diameter total hip arthroplasties. Soft tissue changes including pseudotumours and muscle atrophy have been shown to progress, but this is not consistent. New advanced imaging techniques are helping to diagnose complications with metal hips and the reasons for failure, however these are not widely available. This has led to some centres to tackle difficult cases through multidisciplinary collaboration, for both surgical management decisions and also follow-up decisions. We summarise current evidence and consider who is at risk, when revision should be undertaken and how patients should be managed.

  5. Natural Remission of Major Periprosthetic Osteolysis following Total Hip Arthroplasty with Metal-on-Metal Bearings

    Directory of Open Access Journals (Sweden)

    Tatsuya Tamaki

    2017-01-01

    Full Text Available The natural course of adverse events following the use of metal-on-metal (MoM bearings in total hip arthroplasty (THA is not well known. In this article, we report the case of a patient with asymptomatic major acetabular osteolysis following MoM THA that diminished gradually without any surgical intervention. A 58-year-old male underwent one-stage bilateral MoM THA for bilateral osteoarthritis. Four years after THA, major acetabular osteolysis developed in his right hip without any local or systemic symptoms. The patient underwent a careful radiographic and clinical observation without any surgical intervention because he did not want to undergo revision surgery. The lesion gradually diminished after 7 years, and most of the osteolytic area was replaced by newly formed bone at 10 years. He continues to be followed with no evidence of cup loosening or migration. Our observation suggests that a periprosthetic osteolytic change related to the use of MoM bearings has the potential for natural remission.

  6. Muscle atrophy and metal-on-metal hip implants: a serial MRI study of 74 hips.

    Science.gov (United States)

    Berber, Reshid; Khoo, Michael; Cook, Erica; Guppy, Andrew; Hua, Jia; Miles, Jonathan; Carrington, Richard; Skinner, John; Hart, Alister

    2015-06-01

    Muscle atrophy is seen in patients with metal-on-metal (MOM) hip implants, probably because of inflammatory destruction of the musculo-tendon junction. However, like pseudotumors, it is unclear when atrophy occurs and whether it progresses with time. Our objective was to determine whether muscle atrophy associated with MOM hip implants progresses with time. We retrospectively reviewed 74 hips in 56 patients (32 of them women) using serial MRI. Median age was 59 (23-83) years. The median time post-implantation was 83 (35-142) months, and the median interval between scans was 11 months. Hip muscles were scored using the Pfirrmann system. The mean scores for muscle atrophy were compared between the first and second MRI scans. Blood cobalt and chromium concentrations were determined. The median blood cobalt was 6.84 (0.24-90) ppb and median chromium level was 4.42 (0.20-45) ppb. The median Oxford hip score was 34 (5-48). The change in the gluteus minimus mean atrophy score between first and second MRI was 0.12 (p = 0.002). Mean change in the gluteus medius posterior portion (unaffected by surgical approach) was 0.08 (p = 0.01) and mean change in the inferior portion was 0.10 (p = 0.05). Mean pseudotumor grade increased by 0.18 (p = 0.02). Worsening muscle atrophy and worsening pseudotumor grade occur over a 1-year period in a substantial proportion of patients with MOM hip implants. Serial MRI helps to identify those patients who are at risk of developing worsening soft-tissue pathology. These patients should be considered for revision surgery before irreversible muscle destruction occurs.

  7. Indications for MARS-MRI in Patients Treated With Metal-on-Metal Hip Resurfacing Arthroplasty.

    Science.gov (United States)

    Connelly, James W; Galea, Vincent P; Matuszak, Sean J; Madanat, Rami; Muratoglu, Orhun; Malchau, Henrik

    2018-06-01

    Currently, there are no universally accepted guidelines on when to obtain metal artifact reduction sequence magnetic resonance imaging (MARS-MRI) in metal-on-metal (MoM) hip resurfacing arthroplasty (HRA) patients. Our primary aims were to identify which patient and clinical factors are predictive of adverse local tissue reaction (ALTR) and create an algorithm for indicating MARS-MRI in patients with Articular Surface Replacement (ASR) HRA. The secondary aim was to compare our algorithm to existing guidelines on when to perform MARS-MRI in MoM HRA patients. The study cohort consisted of 182 patients with unilateral ASR HRA from a prospective, multicenter study. Subjects received MARS-MRI at a mean of 7.8 years from surgery, regardless of symptoms. We determined which variables were predictive of ALTR and generated cutoffs for each variable. Finally, we created an algorithm to predict ALTR and indicate MARS-MRI in ASR HRA patients using these cutoffs and compared it to existing guidelines. We found high blood cobalt (Co) (odds ratio = 1.070; P = .011) and high blood chromium (Cr) (odds ratio = 1.162; P = .002) to be significant predictors of ALTR presence. Our algorithm using a blood Co cutoff of 1.15 ppb and a Cr cutoff of 1.09 ppb achieved 96.6% sensitivity and 35.3% specificity in predicting ALTR, which outperformed the existing guidelines. Blood Co and Cr levels are predictive of ALTR in ASR HRA patients. Our algorithm considering blood Co and Cr levels predicts ALTR in ASR HRA patients with higher sensitivity than previously established guidelines. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Microfocus study of metal distribution and speciation in tissue extracted from revised metal on metal hip implants

    International Nuclear Information System (INIS)

    Hart, Alister J; Sandison, Ann; Quinn, Paul; Mosselmans, J Frederick W; Sampson, Barry; Atkinson, Kirk D; Skinner, John A; Goode, Angela; Powell, Jonathan J

    2009-01-01

    Unexplained tissue inflammation in metal-on-metal hip replacements is suspected to be caused by implant-derived nanoparticles. The aim of this study was to investigate the nature of the metal particles in tissue surrounding metal-on-metal (MOM) hips that has been extracted during revision. Mapping of tissue surrounding the failed MOM hips was performed using microfocus X-ray Fluorescence (XRF). This revealed mainly Cr which was localized to the cellular regions. There was co-localisation of Co, were present, to areas of high Cr abundance. XANES of the tissue and appropriate standards revealed that the most common species were Cr(III) and Co(II). EXAFS analysis of the tissue and various metal standards revealed that the most abundant implant-related species was Cr(III) phosphate. Different tissue preparation methods, including frozen sectioning, were examined but were found not to affect the distribution or speciation of the metals in the tissue.

  9. Microfocus study of metal distribution and speciation in tissue extracted from revised metal on metal hip implants

    Energy Technology Data Exchange (ETDEWEB)

    Hart, Alister J [Department of Orthopaedic Surgery, Imperial College and Imperial College Healthcare NHS Trust, Charing Cross Hospital Campus, Fulham Palace Rd, London W6 8RF (United Kingdom); Sandison, Ann [Department of Histopathology, Imperial College and Imperial College Healthcare NHS Trust, Charing Cross Hospital Campus, Fulham Palace Rd, London W6 8RF (United Kingdom); Quinn, Paul; Mosselmans, J Frederick W [Science Division, Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxon, OX11 0DE (United Kingdom); Sampson, Barry [Department of Clinical Biochemistry, Imperial College and Imperial College Healthcare NHS Trust, Charing Cross Hospital Campus, Fulham Palace Rd, London W6 8RF (United Kingdom); Atkinson, Kirk D [8 Nuclear Department Defence Academy College of Management and Technology HMS Sultan Military Road Gosport PO12 3BY (United Kingdom); Skinner, John A [Department of Orthopaedics, Royal National Orthopaedic Hospital, HA7 4LP (United Kingdom); Goode, Angela [Dept of Materials, Imperial College London, SW7 2AZ (United Kingdom); Powell, Jonathan J, E-mail: Paul.Quinn@diamond.ac.u [Medical Research Council Human Nutrition Research Centre, Cambridge CB1 9NL (United Kingdom)

    2009-11-15

    Unexplained tissue inflammation in metal-on-metal hip replacements is suspected to be caused by implant-derived nanoparticles. The aim of this study was to investigate the nature of the metal particles in tissue surrounding metal-on-metal (MOM) hips that has been extracted during revision. Mapping of tissue surrounding the failed MOM hips was performed using microfocus X-ray Fluorescence (XRF). This revealed mainly Cr which was localized to the cellular regions. There was co-localisation of Co, were present, to areas of high Cr abundance. XANES of the tissue and appropriate standards revealed that the most common species were Cr(III) and Co(II). EXAFS analysis of the tissue and various metal standards revealed that the most abundant implant-related species was Cr(III) phosphate. Different tissue preparation methods, including frozen sectioning, were examined but were found not to affect the distribution or speciation of the metals in the tissue.

  10. Assessing for Cardiotoxicity from Metal-on-Metal Hip Implants with Advanced Multimodality Imaging Techniques.

    Science.gov (United States)

    Berber, Reshid; Abdel-Gadir, Amna; Rosmini, Stefania; Captur, Gabriella; Nordin, Sabrina; Culotta, Veronica; Palla, Luigi; Kellman, Peter; Lloyd, Guy W; Skinner, John A; Moon, James C; Manisty, Charlotte; Hart, Alister J

    2017-11-01

    High failure rates of metal-on-metal (MoM) hip implants prompted regulatory authorities to issue worldwide safety alerts. Circulating cobalt from these implants causes rare but fatal autopsy-diagnosed cardiotoxicity. There is concern that milder cardiotoxicity may be common and underrecognized. Although blood metal ion levels are easily measured and can be used to track local toxicity, there are no noninvasive tests for organ deposition. We sought to detect correlation between blood metal ions and a comprehensive panel of established markers of early cardiotoxicity. Ninety patients were recruited into this prospective single-center blinded study. Patients were divided into 3 age and sex-matched groups according to implant type and whole-blood metal ion levels. Group-A patients had a ceramic-on-ceramic [CoC] bearing; Group B, an MoM bearing and low blood metal ion levels; and Group C, an MoM bearing and high blood metal-ion levels. All patients underwent detailed cardiovascular phenotyping using cardiac magnetic resonance imaging (CMR) with T2*, T1, and extracellular volume mapping; echocardiography; and cardiac blood biomarker sampling. T2* is a novel CMR biomarker of tissue metal loading. Blood cobalt levels differed significantly among groups A, B, and C (mean and standard deviation [SD], 0.17 ± 0.08, 2.47 ± 1.81, and 30.0 ± 29.1 ppb, respectively) and between group A and groups B and C combined. No significant between-group differences were found in the left atrial or ventricle size, ejection fraction (on CMR or echocardiography), T1 or T2* values, extracellular volume, B-type natriuretic peptide level, or troponin level, and all values were within normal ranges. There was no relationship between cobalt levels and ejection fraction (R = 0.022, 95% confidence interval [CI] = -0.185 to 0.229) or T2* values (R = 0.108, 95% CI = -0.105 to 0.312). Using the best available technologies, we did not find that high (but not extreme) blood cobalt and chromium levels

  11. The effect of motion patterns on edge-loading of metal-on-metal hip resurfacing.

    Science.gov (United States)

    Mellon, S J; Kwon, Y-M; Glyn-Jones, S; Murray, D W; Gill, H S

    2011-12-01

    The occurrence of pseudotumours (soft tissue masses relating to the hip joint) following metal-on-metal hip resurfacing arthroplasty (MoMHRA) has been associated with high serum metal ion levels and consequently higher than normal bearing wear. We investigated the relationship between serum metal ion levels and contact stress on the acetabular component of MoMHRA patients for two functional activities; gait and stair descent. Four subjects with MoMHRA, who had their serum metal ion levels measured, underwent motion analysis followed by CT scanning. Their motion capture data was combined with published hip contact forces and finite element models representing 14% (peak force) and 60% (end of stance) of the gait cycle and 52% (peak force) of stair descent activity were created. The inclination angle of the acetabular component was increased by 10° in 1° intervals and the contact stresses were determined at each interval for each subject. When the inclination angle was altered in such a way as to cause the hip contact force to pass through the edge of the acetabular component edge-loading occurred. Edge-loading increased the contact stress by at least 50%; the maximum increase was 108%. Patients with low serum metal ion levels showed no increase in contact stress at peak force during gait or stair descent. Patients with high serum metal ion levels exhibited edge-loading with an increase to the inclination angle of their acetabular components. The increase in inclination angle that induced edge-loading for these subjects was less than the inter-subject variability in the angle of published hip contact forces. The results of this study suggest that high serum metal ion levels are the result of inclination angle influenced edge-loading but that edge-loading cannot be attributed to inclination angle alone and that an individual's activity patterns can reduce or even override the influence of a steep acetabular component and prevent edge-loading. Copyright © 2011 IPEM

  12. Information for Patients Who Have Metal-on-Metal Hip Implants

    Science.gov (United States)

    ... both the right and left sides) Patients with resurfacing systems with small femoral heads (device sizes less ... groin area, including the symptoms related to your skin, heart, nervous system, kidneys, or thyroid gland, it ...

  13. Magnetic resonance imaging of metal artifact reduction sequences in the assessment of metal-on-metal hip prostheses

    Directory of Open Access Journals (Sweden)

    Aboelmagd SM

    2014-05-01

    Full Text Available Sharief M Aboelmagd, Paul N Malcolm, Andoni P Toms Department of Radiology, Norfolk and Norwich University Hospital National Health Service Trust, Norwich, UK Abstract: Recent developments in metal artifact reduction techniques in magnetic resonance (MR have, in large part, been stimulated by the advent of soft tissue complications associated with modern metal-on-metal total hip replacements. Metallic orthopedic implants can result in severe degradation of MR images because ferromagnetic susceptibility causes signal loss, signal pile-up, geometric distortion, and failure of fat suppression. There are several approaches to controlling these susceptibility artifacts. Standard fast spin echo sequences can be adapted by modifying echo times, matrix, receiver bandwidth, slice thickness, and echo trains to minimize frequency encoding misregistration. Short tau inversion recovery and 2-point Dixon techniques are both more resistant to susceptibility artifacts than spectral fat suppression. A number of dedicated metal artifact reduction sequences are now available commercially. The common approach of these multispectral techniques is to generate three dimensional datasets from which the final images are reconstructed. Frequency encoding misregistration is controlled using a variety of techniques, including specific resonant frequency acquisition, view-angle tilting, and phase encoding. Metal artifact reduction MR imaging has been the key to understanding the prevalence, severity, and prognosis of adverse reactions to metal debris in metal-on-metal hip replacements. Conventional radiographs are typically normal or demonstrate minimal change and are unable to demonstrate the often extensive soft tissue abnormalities, which include necrosis, soft tissue masses and fluid collections, myositis, muscle atrophy, tendon avulsions, and osteonecrosis. These MR findings correlate poorly with clinical and serological measures of disease, and therefore MR imaging is

  14. Cobalt deposition in mineralized bone tissue after metal-on-metal hip resurfacing: Quantitative μ-X-ray-fluorescence analysis of implant material incorporation in periprosthetic tissue.

    Science.gov (United States)

    Hahn, Michael; Busse, Björn; Procop, Mathias; Zustin, Jozef; Amling, Michael; Katzer, Alexander

    2017-10-01

    Most resurfacing systems are manufactured from cobalt-chromium alloys with metal-on-metal (MoM) bearing couples. Because the quantity of particulate metal and corrosion products which can be released into the periprosthetic milieu is greater in MoM bearings than in metal-on-polyethylene (MoP) bearings, it is hypothesized that the quantity and distribution of debris released by the MoM components induce a compositional change in the periprosthetic bone. To determine the validity of this claim, nondestructive µ-X-ray fluorescence analysis was carried out on undecalcified histological samples from 13 femoral heads which had undergone surface replacement. These samples were extracted from the patients after gradient time points due to required revision surgery. Samples from nonintervened femoral heads as well as from a MoP resurfaced implant served as controls. Light microscopy and µ-X-ray fluorescence analyses revealed that cobalt debris was found not only in the soft tissue around the prosthesis and the bone marrow, but also in the mineralized bone tissue. Mineralized bone exposed to surface replacements showed significant increases in cobalt concentrations in comparison with control specimens without an implant. A maximum cobalt concentration in mineralized hard tissue of up to 380 ppm was detected as early as 2 years after implantation. Values of this magnitude are not found in implants with a MoP surface bearing until a lifetime of more than 20 years. This study demonstrates that hip resurfacing implants with MoM bearings present a potential long-term health risk due to rapid cobalt ion accumulation in periprosthetic hard tissue. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1855-1862, 2017. © 2016 Wiley Periodicals, Inc.

  15. Modified cementless total coxofemoral prosthesis: development, implantation and clinical evaluation

    Directory of Open Access Journals (Sweden)

    S.A. Arias

    2013-12-01

    Full Text Available The aim of this study was to modify canine coxofemoral prostheses and the clinical evaluation of the implantation. Fifteen canine hips and femora of cadavers were used in order to study the surface points of modification in prostheses and develop a perforation guide. Femoral stems and acetabular components were perforated and coated with biphasic calcium phosphate layer. Twelve young adult male mongrel dogs were implanted with coxofemoral prostheses. Six were operated upon and implanted with cemented canine modular hip prostheses, establishing the control group. The remaining six were implanted with a novel design of cementless porous tricalcic phosphate-hydroxyapatite coated hip prostheses. Clinical and orthopedic performance, complications, and thigh muscular hypotrophy were assessed up to the 120th post-operatory day. After 120 days, animals with cementless prostheses had similar clinical and orthopedic performance compared to the cemented group despite the increased pain thigh hypotrophy. Animals that underwent cementless hip prosthesis evidenced more pain, compared to animals with cemented hip prosthesis that required longer recuperation time. No luxations, two fractures and two isquiatic neurapraxies were identified in the course of the study. Using both the cemented and the bioactive coated cementless model were suitable to dogs, showing clinical satisfactory results. Osseointegration and biological fixation were observed in the animals with the modified cementless hip prosthesis.

  16. Pseudotumor from Metal-on-Metal Total Hip Arthroplasty Causing Unilateral Leg Edema: Case Presentation and Literature Review

    Directory of Open Access Journals (Sweden)

    Caleb W. Grote

    2018-03-01

    Full Text Available Metal-on-metal (MoM total hip arthroplasty (THA can be associated with adverse metal reactions, including pseudotumors. This case report describes a 58-year-old female with an MoM THA-related pseudotumor that caused unilateral leg edema from compression of her external iliac vein. After thorough preoperative workup to rule out infection and deep vein thrombosis and consultation with a vascular surgeon, the patient underwent revision THA and excision of her pseudotumor. She had complete resolution of her swelling at 4 years after surgery. Review of all available case reports for this rare complication revealed that almost all patients were female. All patients underwent revision THA, with resolution of their symptoms. Literature review demonstrates that women are disproportionally affected by complications associated with MoM THA. We recommend close monitoring of patients with MoM THA, particularly women, for development of adverse metal reactions.

  17. Metal Ion Concentrations in Body Fluids after Implantation of Hip Replacements with Metal-on-Metal Bearing – Systematic Review of Clinical and Epidemiological Studies

    Science.gov (United States)

    Hartmann, Albrecht; Hannemann, Franziska; Lützner, Jörg; Seidler, Andreas; Drexler, Hans; Günther, Klaus-Peter; Schmitt, Jochen

    2013-01-01

    Introduction The use of metal-on-metal (MoM) total hip arthroplasty (THA) increased in the last decades. A release of metal products (i.e. particles, ions, metallo-organic compounds) in these implants may cause local and/or systemic adverse reactions. Metal ion concentrations in body fluids are surrogate measures of metal exposure. Objective To systematically summarize and critically appraise published studies concerning metal ion concentrations after MoM THA. Methods Systematic review of clinical trials (RCTs) and epidemiological studies with assessment of metal ion levels (cobalt, chromium, titanium, nickel, molybdenum) in body fluids after implantation of metalliferous hip replacements. Systematic search in PubMed and Embase in January 2012 supplemented by hand search. Standardized abstraction of pre- and postoperative metal ion concentrations stratified by type of bearing (primary explanatory factor), patient characteristics as well as study quality characteristics (secondary explanatory factors). Results Overall, 104 studies (11 RCTs, 93 epidemiological studies) totaling 9.957 patients with measurement of metal ions in body fluids were identified and analyzed. Consistently, median metal ion concentrations were persistently elevated after implantation of MoM-bearings in all investigated mediums (whole blood, serum, plasma, erythrocytes, urine) irrespective of patient characteristics and study characteristics. In several studies very high serum cobalt concentrations above 50 µg/L were measured (detection limit typically 0.3 µg/L). Highest metal ion concentrations were observed after treatment with stemmed large-head MoM-implants and hip resurfacing arthroplasty. Discussion Due to the risk of local and systemic accumulation of metallic products after treatment with MoM-bearing, risk and benefits should be carefully balanced preoperatively. The authors support a proposed „time out“ for stemmed large-head MoM-THA and recommend a restricted indication for hip

  18. Metal ion concentrations in body fluids after implantation of hip replacements with metal-on-metal bearing--systematic review of clinical and epidemiological studies.

    Directory of Open Access Journals (Sweden)

    Albrecht Hartmann

    Full Text Available INTRODUCTION: The use of metal-on-metal (MoM total hip arthroplasty (THA increased in the last decades. A release of metal products (i.e. particles, ions, metallo-organic compounds in these implants may cause local and/or systemic adverse reactions. Metal ion concentrations in body fluids are surrogate measures of metal exposure. OBJECTIVE: To systematically summarize and critically appraise published studies concerning metal ion concentrations after MoM THA. METHODS: Systematic review of clinical trials (RCTs and epidemiological studies with assessment of metal ion levels (cobalt, chromium, titanium, nickel, molybdenum in body fluids after implantation of metalliferous hip replacements. Systematic search in PubMed and Embase in January 2012 supplemented by hand search. Standardized abstraction of pre- and postoperative metal ion concentrations stratified by type of bearing (primary explanatory factor, patient characteristics as well as study quality characteristics (secondary explanatory factors. RESULTS: Overall, 104 studies (11 RCTs, 93 epidemiological studies totaling 9.957 patients with measurement of metal ions in body fluids were identified and analyzed. Consistently, median metal ion concentrations were persistently elevated after implantation of MoM-bearings in all investigated mediums (whole blood, serum, plasma, erythrocytes, urine irrespective of patient characteristics and study characteristics. In several studies very high serum cobalt concentrations above 50 µg/L were measured (detection limit typically 0.3 µg/L. Highest metal ion concentrations were observed after treatment with stemmed large-head MoM-implants and hip resurfacing arthroplasty. DISCUSSION: Due to the risk of local and systemic accumulation of metallic products after treatment with MoM-bearing, risk and benefits should be carefully balanced preoperatively. The authors support a proposed "time out" for stemmed large-head MoM-THA and recommend a restricted

  19. Acetabular bone density and metal ions after metal-on-metal versus metal-on-polyethylene total hip arthroplasty; short-term results

    NARCIS (Netherlands)

    Zijlstra, Wierd P.; van der Veen, Hugo C.; van den Akker-Scheek, Inge; Zee, Mark J. M.; Bulstra, Sjoerd K.; van Raay, Jos J. A. M.

    Information on periprosthetic acetabular bone density is lacking for metal-on-metal total hip arthroplasties. These bearings use cobalt-chromium instead of titanium acetabular components, which could lead to stress shielding and hence periprosthetic bone loss. Cobalt and chromium ions have

  20. International metal-on-metal multidisciplinary teams: do we manage patients with metal-on-metal hip arthroplasty in the same way? An analysis from the International Specialist Centre Collaboration on MOM Hips (ISCCoMH).

    Science.gov (United States)

    Berber, R; Skinner, J; Board, T; Kendoff, D; Eskelinen, A; Kwon, Y-M; Padgett, D E; Hart, A

    2016-02-01

    There are many guidelines that help direct the management of patients with metal-on-metal (MOM) hip arthroplasties. We have undertaken a study to compare the management of patients with MOM hip arthroplasties in different countries. Six international tertiary referral orthopaedic centres were invited to participate by organising a multi-disciplinary team (MDT) meeting, consisting of two or more revision hip arthroplasty surgeons and a musculoskeletal radiologist. A full clinical dataset including history, blood tests and imaging for ten patients was sent to each unit, for discussion and treatment planning. Differences in the interpretation of findings, management decisions and rationale for decisions were compared using quantitative and qualitative methods. Overall agreement between the orthopaedic centres and the recommended treatment plans for the ten patients with MOM hip implants was moderate (kappa = 0.6). Full agreement was seen in a third of cases, however split decisions were also seen in a third of cases. Units differed in their interpretation of the significance of the investigation findings and put varying emphasis on serial changes, in the presence of symptoms. In conclusion, the management of raised or rising blood metal ions, cystic pseudotumours and peri-acetabular osteolysis led to inconsistency in the agreement between centres. Coordinated international guidance and MDT panel discussions are recommended to improve consensus in decision making. A lack of evidence and the subsequent variation in regulator guidance leads to differences in opinions, the clinical impact of which can be reduced through a multi-disciplinary team approach to managing patients with MOM hip implants. Cite this article: Bone Joint J 2016;98-B:179-86. ©2016 The British Editorial Society of Bone & Joint Surgery.

  1. Characterization of wear debris from metal-on-metal hip implants during normal wear versus edge-loading conditions.

    Science.gov (United States)

    Kovochich, Michael; Fung, Ernest S; Donovan, Ellen; Unice, Kenneth M; Paustenbach, Dennis J; Finley, Brent L

    2018-04-01

    Advantages of second-generation metal-on-metal (MoM) hip implants include low volumetric wear rates and the release of nanosized wear particles that are chemically inert and readily cleared from local tissue. In some patients, edge loading conditions occur, which result in higher volumetric wear. The objective of this study was to characterize the size, morphology, and chemistry of wear particles released from MoM hip implants during normal (40° angle) and edge-loading (65° angle with microseparation) conditions. The mean primary particle size by volume under normal wear was 35 nm (range: 9-152 nm) compared with 95 nm (range: 6-573 nm) under edge-loading conditions. Hydrodynamic diameter analysis by volume showed that particles from normal wear were in the nano- (edge-loading conditions generated particles that ranged from Edge-loading conditions generated more elongated particles (4.5%) (aspect ratio ≥ 2.5) and more CoCr alloy particles (9.3%) compared with normal wear conditions (1.3% CoCr particles). By total mass, edge-loading particles contained approximately 640-fold more cobalt than normal wear particles. Our findings suggest that high wear conditions are a potential risk factor for adverse local tissue effects in MoM patients who experience edge loading. This study is the first to characterize both the physical and chemical characteristics of MoM wear particles collected under normal and edge-loading conditions. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 986-996, 2018. © 2017 Wiley Periodicals, Inc.

  2. A simulator study of adverse wear with metal and cement debris contamination in metal-on-metal hip bearings.

    Science.gov (United States)

    Halim, T; Clarke, I C; Burgett-Moreno, M D; Donaldson, T K; Savisaar, C; Bowsher, J G

    2014-03-01

    Third-body wear is believed to be one trigger for adverse results with metal-on-metal (MOM) bearings. Impingement and subluxation may release metal particles from MOM replacements. We therefore challenged MOM bearings with relevant debris types of cobalt-chrome alloy (CoCr), titanium alloy (Ti6Al4V) and polymethylmethacrylate bone cement (PMMA). Cement flakes (PMMA), CoCr and Ti6Al4V particles (size range 5 µm to 400 µm) were run in a MOM wear simulation. Debris allotments (5 mg) were inserted at ten intervals during the five million cycle (5 Mc) test. In a clean test phase (0 Mc to 0.8 Mc), lubricants retained their yellow colour. Addition of metal particles at 0.8 Mc turned lubricants black within the first hour of the test and remained so for the duration, while PMMA particles did not change the colour of the lubricant. Rates of wear with PMMA, CoCr and Ti6Al4V debris averaged 0.3 mm(3)/Mc, 4.1 mm(3)/Mc and 6.4 mm(3)/Mc, respectively. Metal particles turned simulator lubricants black with rates of wear of MOM bearings an order of magnitude higher than with control PMMA particles. This appeared to model the findings of black, periarticular joint tissues and high CoCr wear in failed MOM replacements. The amount of wear debris produced during a 500 000-cycle interval of gait was 30 to 50 times greater than the weight of triggering particle allotment, indicating that MOM bearings were extremely sensitive to third-body wear. Cite this article: Bone Joint Res 2015;4:29-37. ©2015 The British Editorial Society of Bone & Joint Surgery.

  3. Lymphoid Aggregates That Resemble Tertiary Lymphoid Organs Define a Specific Pathological Subset in Metal-on-Metal Hip Replacements

    Science.gov (United States)

    Barone, Francesca; Hardie, Debbie L.; Matharu, Gulraj S.; Davenport, Alison J.; Martin, Richard A.; Grant, Melissa; Mosselmans, Frederick; Pynsent, Paul; Sumathi, Vaiyapuri P.; Addison, Owen; Revell, Peter A.; Buckley, Christopher D.

    2013-01-01

    Aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL) has been used to describe the histological lesion associated with metal-on-metal (M-M) bearings. We tested the hypothesis that the lymphoid aggregates, associated with ALVAL lesions resemble tertiary lymphoid organs (TLOs). Histopathological changes were examined in the periprosthetic tissue of 62 M-M hip replacements requiring revision surgery, with particular emphasis on the characteristics and pattern of the lymphocytic infiltrate. Immunofluorescence and immunohistochemistry were used to study the classical features of TLOs in cases where large organized lymphoid follicles were present. Synchrotron X-ray fluorescence (XRF) measurements were undertaken to detect localisation of implant derived ions/particles within the samples. Based on type of lymphocytic infiltrates, three different categories were recognised; diffuse aggregates (51%), T cell aggregates (20%), and organised lymphoid aggregates (29%). Further investigation of tissues with organised lymphoid aggregates showed that these tissues recapitulate many of the features of TLOs with T cells and B cells organised into discrete areas, the presence of follicular dendritic cells, acquisition of high endothelial venule like phenotype by blood vessels, expression of lymphoid chemokines and the presence of plasma cells. Co-localisation of implant-derived metals with lymphoid aggregates was observed. These findings suggest that in addition to the well described general foreign body reaction mediated by macrophages and a T cell mediated type IV hypersensitivity response, an under-recognized immunological reaction to metal wear debris involving B cells and the formation of tertiary lymphoid organs occurs in a distinct subset of patients with M-M implants. PMID:23723985

  4. The tridimensional geometry of the proximal femur should determine the design of cementless femoral stem in total hip arthroplasty.

    Science.gov (United States)

    Wegrzyn, Julien; Roux, Jean-Paul; Loriau, Charlotte; Bonin, Nicolas; Pibarot, Vincent

    2018-02-22

    Using a cementless femoral stem in total hip arthroplasty (THA), optimal filling of the proximal femoral metaphyseal volume (PFMV) and restoration of the extramedullary proximal femoral (PF) parameters (i.e., femoral offset (FO), neck length (FNL), and head height (FHH)) constitute key goals for optimal hip biomechanics, functional outcome, and THA survivorship. However, almost 30% of mismatch between the PF anatomy and implant geometry of the most widely implanted non-modular cementless femoral stem has been demonstrated in a computed tomography scan (CT scan) study. Therefore, this anatomic study aimed to evaluate the relationship between the intra- and extramedullary PF parameters using tridimensional CT scan reconstructions. One hundred fifty-one CT scans of adult healthy hips were obtained from 151 male Caucasian patients (mean age = 66 ± 11 years) undergoing lower limb CT scan arteriography. Tridimensional PF reconstructions and parameter measurements were performed using a corrected PF coronal plane-defined by the femoral neck and diaphyseal canal longitudinal axes-to avoid influence of PF helitorsion and femoral neck version on extramedullary PF parameters. Independently of the femoral neck-shaft angle, the PFMV was significantly and positively correlated with the FO, FNL, and FHH (r = 0.407 to 0.420; p < 0.0001). This study emphasized that the tridimensional PF geometry measurement in the corrected coronal plane of the femoral neck can be useful to determine and optimize the design of a non-modular cementless femoral stem. Particularly, continuous homothetic size progression of the intra- and extramedullary PF parameters should be achieved to assure stem fixation and restore anatomic hip biomechanics.

  5. Advanced metal artifact reduction MRI of metal-on-metal hip resurfacing arthroplasty implants: compressed sensing acceleration enables the time-neutral use of SEMAC

    International Nuclear Information System (INIS)

    Fritz, Jan; Thawait, Gaurav K.; Fritz, Benjamin; Raithel, Esther; Nittka, Mathias; Gilson, Wesley D.; Mont, Michael A.

    2016-01-01

    Compressed sensing (CS) acceleration has been theorized for slice encoding for metal artifact correction (SEMAC), but has not been shown to be feasible. Therefore, we tested the hypothesis that CS-SEMAC is feasible for MRI of metal-on-metal hip resurfacing implants. Following prospective institutional review board approval, 22 subjects with metal-on-metal hip resurfacing implants underwent 1.5 T MRI. We compared CS-SEMAC prototype, high-bandwidth TSE, and SEMAC sequences with acquisition times of 4-5, 4-5 and 10-12 min, respectively. Outcome measures included bone-implant interfaces, image quality, periprosthetic structures, artifact size, and signal- and contrast-to-noise ratios (SNR and CNR). Using Friedman, repeated measures analysis of variances, and Cohen's weighted kappa tests, Bonferroni-corrected p-values of 0.005 and less were considered statistically significant. There was no statistical difference of outcomes measures of SEMAC and CS-SEMAC images. Visibility of implant-bone interfaces and pseudocapsule as well as fat suppression and metal reduction were ''adequate'' to ''good'' on CS-SEMAC and ''non-diagnostic'' to ''adequate'' on high-BW TSE (p < 0.001, respectively). SEMAC and CS-SEMAC showed mild blur and ripple artifacts. The metal artifact size was 63 % larger for high-BW TSE as compared to SEMAC and CS-SEMAC (p < 0.0001, respectively). CNRs were sufficiently high and statistically similar, with the exception of CNR of fluid and muscle and CNR of fluid and tendon, which were higher on intermediate-weighted high-BW TSE (p < 0.005, respectively). Compressed sensing acceleration enables the time-neutral use of SEMAC for MRI of metal-on-metal hip resurfacing implants when compared to high-BW TSE and image quality similar to conventional SEMAC. (orig.)

  6. Advanced metal artifact reduction MRI of metal-on-metal hip resurfacing arthroplasty implants: compressed sensing acceleration enables the time-neutral use of SEMAC

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, Jan; Thawait, Gaurav K. [Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Science, Section of Musculoskeletal Radiology, Baltimore, MD (United States); Fritz, Benjamin [University of Freiburg, Department of Radiology, Freiburg im Breisgau (Germany); Raithel, Esther; Nittka, Mathias [Siemens Healthcare GmbH, Erlangen (Germany); Gilson, Wesley D. [Siemens Healthcare USA, Inc., Baltimore, MD (United States); Mont, Michael A. [Cleveland Clinic Foundation, Department of Orthopedic Surgery, Cleveland, OH (United States)

    2016-10-15

    Compressed sensing (CS) acceleration has been theorized for slice encoding for metal artifact correction (SEMAC), but has not been shown to be feasible. Therefore, we tested the hypothesis that CS-SEMAC is feasible for MRI of metal-on-metal hip resurfacing implants. Following prospective institutional review board approval, 22 subjects with metal-on-metal hip resurfacing implants underwent 1.5 T MRI. We compared CS-SEMAC prototype, high-bandwidth TSE, and SEMAC sequences with acquisition times of 4-5, 4-5 and 10-12 min, respectively. Outcome measures included bone-implant interfaces, image quality, periprosthetic structures, artifact size, and signal- and contrast-to-noise ratios (SNR and CNR). Using Friedman, repeated measures analysis of variances, and Cohen's weighted kappa tests, Bonferroni-corrected p-values of 0.005 and less were considered statistically significant. There was no statistical difference of outcomes measures of SEMAC and CS-SEMAC images. Visibility of implant-bone interfaces and pseudocapsule as well as fat suppression and metal reduction were ''adequate'' to ''good'' on CS-SEMAC and ''non-diagnostic'' to ''adequate'' on high-BW TSE (p < 0.001, respectively). SEMAC and CS-SEMAC showed mild blur and ripple artifacts. The metal artifact size was 63 % larger for high-BW TSE as compared to SEMAC and CS-SEMAC (p < 0.0001, respectively). CNRs were sufficiently high and statistically similar, with the exception of CNR of fluid and muscle and CNR of fluid and tendon, which were higher on intermediate-weighted high-BW TSE (p < 0.005, respectively). Compressed sensing acceleration enables the time-neutral use of SEMAC for MRI of metal-on-metal hip resurfacing implants when compared to high-BW TSE and image quality similar to conventional SEMAC. (orig.)

  7. Usefulness of metal artifact reduction with WARP technique at 1.5 and 3T MRI in imaging metal-on-metal hip resurfacings

    Energy Technology Data Exchange (ETDEWEB)

    Lazik, Andrea; Lauenstein, Thomas C.; Theysohn, Jens M. [University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Landgraeber, Stefan; Schulte, Patrick [University Hospital Essen, Department of Orthopedics, Essen (Germany); Kraff, Oliver [University of Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany)

    2015-03-25

    To evaluate the usefulness of the metal artifact reduction technique ''WARP'' in the assessment of metal-on-metal hip resurfacings at 1.5 and 3T in the context of image quality and imaging speed. Nineteen patients (25 hip resurfacings) were randomized for 1.5 and 3T MRI, both including T1 and T2 turbo spin-echo as well as turbo inversion recovery magnitude sequences with and without view angle tilting and high bandwidth. Additional 3T sequences were acquired with a reduced number of averages and using the parallel acquisition technique for accelerating imaging speed. Artifact size (diameter, area), image quality (5-point scale) and delineation of anatomical structures were compared among the techniques, sequences and field strengths using the Wilcoxon sign-rank and paired t-test with Bonferroni correction. At both field strengths, WARP showed significant superiority over standard sequences regarding image quality, artifact size and delineation of anatomical structures. At 3T, artifacts were larger compared to 1.5T without affecting diagnostic quality, and scanning time could be reduced by up to 64 % without quality degradation. WARP proved useful in imaging metal-on-metal hip resurfacings at 1.5T as well as 3T with better image quality surrounding the implants. At 3T imaging could be considerably accelerated without losing diagnostic quality. (orig.)

  8. Usefulness of metal artifact reduction with WARP technique at 1.5 and 3T MRI in imaging metal-on-metal hip resurfacings

    International Nuclear Information System (INIS)

    Lazik, Andrea; Lauenstein, Thomas C.; Theysohn, Jens M.; Landgraeber, Stefan; Schulte, Patrick; Kraff, Oliver

    2015-01-01

    To evaluate the usefulness of the metal artifact reduction technique ''WARP'' in the assessment of metal-on-metal hip resurfacings at 1.5 and 3T in the context of image quality and imaging speed. Nineteen patients (25 hip resurfacings) were randomized for 1.5 and 3T MRI, both including T1 and T2 turbo spin-echo as well as turbo inversion recovery magnitude sequences with and without view angle tilting and high bandwidth. Additional 3T sequences were acquired with a reduced number of averages and using the parallel acquisition technique for accelerating imaging speed. Artifact size (diameter, area), image quality (5-point scale) and delineation of anatomical structures were compared among the techniques, sequences and field strengths using the Wilcoxon sign-rank and paired t-test with Bonferroni correction. At both field strengths, WARP showed significant superiority over standard sequences regarding image quality, artifact size and delineation of anatomical structures. At 3T, artifacts were larger compared to 1.5T without affecting diagnostic quality, and scanning time could be reduced by up to 64 % without quality degradation. WARP proved useful in imaging metal-on-metal hip resurfacings at 1.5T as well as 3T with better image quality surrounding the implants. At 3T imaging could be considerably accelerated without losing diagnostic quality. (orig.)

  9. MR imaging with metal artifact-reducing sequences and gadolinium contrast agent in a case-control study of periprosthetic abnormalities in patients with metal-on-metal hip prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Gunilla M.; Mueller, Markus F.; Ekberg, Olle [Lund University, Skaane University Hospital, Department of Radiology, Malmoe (Sweden); Maansson, Sven [Lund University, Skaane University Hospital, Department of Medical Radiation Physics, Malmoe (Sweden); Schewelov, Thord von [Lund University, Skaane University Hospital, Department of Orthopedic Surgery, Malmoe (Sweden); Nittka, Mathias [Siemens AG, Healthcare Sector, Erlangen (Germany); Lundin, Bjoern [Lund University, Skaane University Hospital, Department of Radiology, Lund (Sweden)

    2014-08-15

    To apply and compare magnetic resonance imaging (MRI) metal artifact reducing sequences (MARS) including subtraction imaging after contrast application in patients with metal-on-metal (MoM) hip prostheses, investigate the prevalence and characteristics of periprosthetic abnormalities, as well as their relation with pain and risk factors. Fifty-two MoM prostheses (35 cases with pain and or risk factors, and 17 controls) in 47 patients were examined in a 1.5-T MR scanner using MARS: turbo spin echo (TSE) with high readout bandwidth with and without view angle tilting (VAT), TSE with VAT and slice encoding for metal artifact correction (SEMAC), short tau inversion recovery (STIR) with matched RF pulses, and post-contrast imaging. The relations of MRI findings to pain and risk factors were analyzed and in five revised hips findings from operation, histology, and MRI were compared. TSE VAT detected the highest number of osteolyses. Soft tissue mass, effusion, and capsular thickening were common, whereas osteolysis in acetabulum and femur were less frequent. Contrast enhancement occurred in bone, synovia, joint capsule, and the periphery of soft tissue mass. There was no significant relation between MRI findings and pain or risk factors. MARS and gadolinium subtraction imaging are useful for evaluation of complications to MoM prosthesis. TSE VAT had the highest sensitivity for osteolysis. Contrast enhancement might indicate activation of aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL). Pain, small head, or steep prosthesis inclination angle are not useful predictors of periprosthetic abnormalities, and wide indications for MR follow-up are warranted. (orig.)

  10. The Infection Rate of Metal-on-Metal Total Hip Replacement Is Higher When Compared to Other Bearing Surfaces as Documented by the Australian Orthopaedic Association National Joint Replacement Registry.

    Science.gov (United States)

    Huang, Phil; Lyons, Matt; O'Sullivan, Michael

    2018-02-01

    Despite the well-documented decline in the use of metal-on-metal (MoM) implants over the last decade, there are still controversies regarding whether all MoM implants are created equally. Complications such as elevated serum metal ion levels, aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL) and pseudotumours have all been well documented, but recent studies suggest increased risk of infection with MoM bearing surfaces. Most of these studies however have small patient numbers. The purpose of this study was to examine the cumulative incidence of revision for infection of MoM bearing surfaces in primary hip arthroplasty at a national and single-surgeon level. Data was collected from the Australian Orthopaedic Association National Joint Replacement Registry, which contains over 98% of all arthroplasties performed in Australia since 2001. The cumulative incidence of revision for infection was extracted at a national level and single-surgeon level. Two hundred seventy-six thousand eight hundred seventy-eight subjects were documented in the Australian registry. The 10-year cumulative percent revision for infection of MoM bearing surfaces in primary total hip replacement (THR) was 2.5% at a national level, compared to 0.8% for other bearing surfaces. The senior author contributed 1755 subjects with 7-year follow-up and a cumulative percent revision for infection of MoM bearing surfaces in primary THR of 36.9%, compared to 2.0% for other bearing surfaces. The cumulative percent of revision of MoM bearing surfaces is higher compared to other bearing surfaces; this is especially pronounced in cumulative percent of revision for infection. There was a higher cumulative percent of revision for infection in MoM bearings surfaces (in particular, large-head MoM) compared to other bearing surfaces at both the national and individual-surgeon level.

  11. Technical note: Comparison of metal-on-metal hip simulator wear measured by gravimetric, CMM and optical profiling methods

    Science.gov (United States)

    Alberts, L. Russell; Martinez-Nogues, Vanesa; Baker Cook, Richard; Maul, Christian; Bills, Paul; Racasan, R.; Stolz, Martin; Wood, Robert J. K.

    2018-03-01

    Simulation of wear in artificial joint implants is critical for evaluating implant designs and materials. Traditional protocols employ the gravimetric method to determine the loss of material by measuring the weight of the implant components before and after various test intervals and after the completed test. However, the gravimetric method cannot identify the location, area coverage or maximum depth of the wear and it has difficulties with proportionally small weight changes in relatively heavy implants. In this study, we compare the gravimetric method with two geometric surface methods; an optical light method (RedLux) and a coordinate measuring method (CMM). We tested ten Adept hips in a simulator for 2 million cycles (MC). Gravimetric and optical methods were performed at 0.33, 0.66, 1.00, 1.33 and 2 MC. CMM measurements were done before and after the test. A high correlation was found between the gravimetric and optical methods for both heads (R 2  =  0.997) and for cups (R 2  =  0.96). Both geometric methods (optical and CMM) measured more volume loss than the gravimetric method (for the heads, p  =  0.004 (optical) and p  =  0.08 (CMM); for the cups p  =  0.01 (optical) and p  =  0.003 (CMM)). Two cups recorded negative wear at 2 MC by the gravimetric method but none did by either the optical method or by CMM. The geometric methods were prone to confounding factors such as surface deformation and the gravimetric method could be confounded by protein absorption and backside wear. Both of the geometric methods were able to show the location, area covered and depth of the wear on the bearing surfaces, and track their changes during the test run; providing significant advantages to solely using the gravimetric method.

  12. Grading the severity of soft tissue changes associated with metal-on-metal hip replacements: reliability of an MR grading system

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Helen; Cahir, John G.; Goodwin, Richard W. [Norfolk and Norwich University Hospital, Department of Radiology, Norwich, Norfolk (United Kingdom); Toms, Andoni Paul [Norfolk and Norwich University Hospital, Department of Radiology, Norwich, Norfolk (United Kingdom); Norwich Radiology Academy, Norwich (United Kingdom); Wimhurst, James; Nolan, John F. [Norfolk and Norwich University Hospital, Department of Orthopaedics, Norwich, Norfolk (United Kingdom)

    2011-03-15

    Metal-on-metal (MoM) soft tissue reactions or aseptic lymphocytic vasculitis-associated lesions (ALVAL) are being recognised using metal artefact reduction (MAR) MR with increasing frequency following the advent of second generation metal-on-metal bearings, but there is no standardised technique for reporting of MR appearances in this disease. The aim of this study was to measure the reliability of a grading system designed for scoring the severity of MoM disease on MRI. MRI examinations of 73 hips in 59 patients were retrospectively selected and then anonymised, randomised and reviewed by three independent observers (musculoskeletal radiologists). Each MR examination was scored as either A: normal, B: infection, C1: mild MoM disease, C2: moderate MoM disease or C3: severe MoM disease according to pre-defined criteria. Kappa correlation statistics were used to compare the observations. There was substantial agreement among all three observers; the correlation coefficient between the two most experienced observers was {kappa} = 0.78 [95% confidence intervals (CI): 0.68-0.88] and when compared with the least experienced observer coefficients were {kappa} = 0.69 (95% CI: 0.57-0.80) and {kappa} = 0.66 (95% CI: 0.54-0.78). The strongest correlation occurred for grades A, C2 and C3. The weakest correlations occurred for grades B and C1. The grading system described in this study is reliable for evaluating ALVAL in MoM prostheses using MR but is limited in differentiating mild disease from infection. (orig.)

  13. Two-stage revision surgery with preformed spacers and cementless implants for septic hip arthritis: a prospective, non-randomized cohort study

    Directory of Open Access Journals (Sweden)

    Logoluso Nicola

    2011-05-01

    Full Text Available Abstract Background Outcome data on two-stage revision surgery for deep infection after septic hip arthritis are limited and inconsistent. This study presents the medium-term results of a new, standardized two-stage arthroplasty with preformed hip spacers and cementless implants in a consecutive series of adult patients with septic arthritis of the hip treated according to a same protocol. Methods Nineteen patients (20 hips were enrolled in this prospective, non-randomized cohort study between 2000 and 2008. The first stage comprised femoral head resection, debridement, and insertion of a preformed, commercially available, antibiotic-loaded cement hip spacer. After eradication of infection, a cementless total hip arthroplasty was implanted in the second stage. Patients were assessed for infection recurrence, pain (visual analog scale [VAS] and hip joint function (Harris Hip score. Results The mean time between first diagnosis of infection and revision surgery was 5.8 ± 9.0 months; the average duration of follow up was 56.6 (range, 24 - 104 months; all 20 hips were successfully converted to prosthesis an average 22 ± 5.1 weeks after spacer implantation. Reinfection after total hip joint replacement occurred in 1 patient. The mean VAS pain score improved from 48 (range, 35 - 84 pre-operatively to 18 (range, 0 - 38 prior to spacer removal and to 8 (range, 0 - 15 at the last follow-up assessment after prosthesis implantation. The average Harris Hip score improved from 27.5 before surgery to 61.8 between the two stages to 92.3 at the final follow-up assessment. Conclusions Satisfactory outcomes can be obtained with two-stage revision hip arthroplasty using preformed spacers and cementless implants for prosthetic hip joint infections of various etiologies.

  14. Do large heads enhance stability and restore native anatomy in primary total hip arthroplasty?

    Science.gov (United States)

    Lombardi, Adolph V; Skeels, Michael D; Berend, Keith R; Adams, Joanne B; Franchi, Orlando J

    2011-06-01

    Dislocation remains a serious complication in hip arthroplasty. Resurfacing proponents tout anatomic femoral head restoration as an advantage over total hip arthroplasty. However, advances in bearings have expanded prosthetic head options from traditional sizes of 22, 26, 28, and 32 mm to diameters as large as 60 mm. Large heads reportedly enhance stability owing to increased range of motion before impingement and increased jump distance to subluxation. Available larger diameter material combinations include metal- or ceramic-on-highly crosslinked polyethylene and metal-on-metal, each with distinct advantages and disadvantages. We sought to determine (1) if using larger diameter heads has lowered our dislocation rate; and (2) how closely an anatomic metal-on-metal bearing with diameters to 60 mm replicates native femoral head size. We retrospectively reviewed 2020 primary arthroplasties performed with large heads (≥ 36 mm) in 1748 patients and noted dislocation incidence. In a prospective subset of 89 cases using anatomic heads, native femoral head diameter was measured intraoperatively with calipers by an independent observer and later compared with implanted size. One dislocation has occurred in 2020 hips for an incidence of 0.05%. The prosthetic head averaged 0.7 mm larger than the native head with 68 of 89 (76%) reconstructed to within ± 2 mm of native size. Larger diameter heads have contributed to lower dislocation rates and large-diameter metal-on-metal articulation can provide close anatomic restoration in primary THA.

  15. Sports Activity Following Cementless Metaphyseal Hip Joint Arthroplasty.

    Science.gov (United States)

    Czech, Szymon; Hermanson, Jacek; Rodak, Piotr; Stołtny, Tomasz; Rodak, Łukasz; Kasperczyk, Sławomir; Koczy, Bogdan; Mielnik, Michał

    2017-12-01

    An adequate level of physical activity has a substantial effect on both mental and physical human health. Physical activity is largely dependent on the function of the musculoskeletal and articular system. One of the most frequent diseases of this system is degenerative joint disease. Due to the changing and more demanding lifestyles and patients' willingness to be involved in sports activity, the expectations of hip joint arthroplasty are becoming increasingly high. Alleviating pain ceases to be the only reason for which patients choose surgical interventions, while the expectations often include involvement in various sports. Only few studies contain recommendations concerning the frequency, type and intensity of sports activity which are acceptable after hip joint arthroplasty. The aim of the study was to evaluate function and physical activity of people following cementless short-stem hip joint arthroplasty in the observation of at least five years. The study group comprised 106 patients who underwent total hip arthroplasty due to degenerative joint diseases, chosen according to inclusion criteria. Patients underwent routine physical examinations following the Harris Hip Score protocol, responded to the UCLA scale and questionnaires concerning pre-surgical and current physical activity. Our results demonstrated that hip joint arthroplasty in people suffering from degenerative joint diseases has a beneficial effect on their level of functioning and physical activity. Although physical activity and the level of functioning obviously reduced as a person aged, the level of physical activity continued to be very high in both groups, with function of the hip joint evaluated as very good.

  16. N-Acetyl-Cysteine as Effective and Safe Chelating Agent in Metal-on-Metal Hip-Implanted Patients: Two Cases

    Directory of Open Access Journals (Sweden)

    Andrea Giampreti

    2016-01-01

    Full Text Available Systemic toxicity associated with cobalt (Co and chromium (Cr containing metal hip alloy may result in neuropathy, cardiomyopathy, and hypothyroidism. However clinical management concerning chelating therapy is still debated in literature. Here are described two metal-on-metal hip-implanted patients in which N-acetyl-cysteine decreased elevated blood metal levels. A 67-year-old male who underwent Co/Cr hip implant in September 2009 referred to our Poison Control Centre for persisting elevated Co/Cr blood levels (from March 2012 to November 2014. After receiving oral high-dose N-acetyl-cysteine, Co/Cr blood concentrations dropped by 86% and 87% of the prechelation levels, respectively, and persisted at these latter concentrations during the following 6 months of follow-up. An 81-year-old female who underwent Co/Cr hip implant in January 2007 referred to our Centre for detection of high Co and Cr blood levels in June 2012. No hip revision was indicated. After a therapy with oral high-dose N-acetyl-cysteine Co/Cr blood concentrations decreased of 45% and 24% of the prechelation levels. Chelating agents reported in hip-implanted patients (EDTA, DMPS, and BAL are described in few cases. N-acetyl-cysteine may provide chelating sites for metals and in our cases reduced Co and Cr blood levels and resulted well tolerable.

  17. Sports Activity Following Cementless Metaphyseal Hip Joint Arthroplasty

    Directory of Open Access Journals (Sweden)

    Czech Szymon

    2017-12-01

    Full Text Available An adequate level of physical activity has a substantial effect on both mental and physical human health. Physical activity is largely dependent on the function of the musculoskeletal and articular system. One of the most frequent diseases of this system is degenerative joint disease. Due to the changing and more demanding lifestyles and patients’ willingness to be involved in sports activity, the expectations of hip joint arthroplasty are becoming increasingly high. Alleviating pain ceases to be the only reason for which patients choose surgical interventions, while the expectations often include involvement in various sports. Only few studies contain recommendations concerning the frequency, type and intensity of sports activity which are acceptable after hip joint arthroplasty. The aim of the study was to evaluate function and physical activity of people following cementless short-stem hip joint arthroplasty in the observation of at least five years. The study group comprised 106 patients who underwent total hip arthroplasty due to degenerative joint diseases, chosen according to inclusion criteria. Patients underwent routine physical examinations following the Harris Hip Score protocol, responded to the UCLA scale and questionnaires concerning pre-surgical and current physical activity. Our results demonstrated that hip joint arthroplasty in people suffering from degenerative joint diseases has a beneficial effect on their level of functioning and physical activity. Although physical activity and the level of functioning obviously reduced as a person aged, the level of physical activity continued to be very high in both groups, with function of the hip joint evaluated as very good.

  18. Still no single gold standard for using cementless femoral stems routinely in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Joseph T. Moskal, MD

    2016-12-01

    Conclusions: Using evidence-based data should be better guidance in selecting the most reliable implants for THA. Although cementless femoral fixation for THA has evolved to the “new standard,” it has not been proven to be the “gold standard” for all patients.

  19. Effect of rotator cuff dysfunction on the initial mechanical stability of cementless glenoid components

    NARCIS (Netherlands)

    D.R. Suárez (Daniel); E.R. Valstar (Edward); J.C. Linden (Jacqueline); F. van Keulen (Fred); P.M. Rozing (Piet)

    2009-01-01

    textabstractThe functional outcome of shoulder replacement is related to the condition of the rotator cuff. Rotator cuff disease is a common problem in candidates for total shoulder arthroplasty; this study relates the functional status of the rotator cuff to the initial stability of a cementless

  20. A biodegradable gentamicin-hydroxyapatite-coating for infection prophylaxis in cementless hip prostheses

    NARCIS (Netherlands)

    Neut, D.; Dijkstra, R. J. B.; Thompson, J. I.; Kavanagh, C.; van der Mei, H. C.; Busscher, H. J.

    2015-01-01

    A degradable, poly (lactic-co-glycolic acid) (PLGA), gentamicin-loaded prophylactic coating for hydroxyapatite (HA)-coated cementless hip prostheses is developed with similar antibacterial efficacy as offered by gentamicin-loaded cements for fixing traditional, cemented prostheses in bone. We

  1. A cementless, proximally fixed anatomic femoral stem induces high micromotion with nontraumatic femoral avascular necrosis: A finite element study

    Directory of Open Access Journals (Sweden)

    Wen-Chuan Chen

    2014-07-01

    Full Text Available Decrease in bone mineral density of metaphysis in patients with nontraumatic avascular necrosis of the femoral head (AVN is considered the main factor leading to aseptic loosening of the femoral component. Researchers have hypothesized that a cementless, anatomic stem fixed proximally to the metaphysis has a higher risk for aseptic loosening than a straight stem that is fixed at the diaphysis in patients with nontraumatic AVN. The purpose of the current study was to evaluate the effects of cancellous bone stiffness at the metaphysis and stem geometry on the micromotion of the femoral stem relative to the femur. The VerSys (straight and ABG (anatomic femoral stems were enrolled in this finite element study to determine the performance of prosthetic micromotion. The simulated load to the hip joint during heel strike was assigned. Results showed that the VerSys model represented better resistance in micromotion between the bone/stem interface than the ABG model in either normal or poor cancellous bone stiffness at the metaphysis. The bone quality at the metaphysis of patients with nontraumatic AVN should be considered prior to selecting a femoral stem. In consideration of initial stability, acementless, straight stem that fits the isthmus is more favourable than an anatomic stem that is fixed to the proximal area of the canal.

  2. Prospective, randomized multicenter study of cervical arthroplasty versus anterior cervical discectomy and fusion: 5-year results with a metal-on-metal artificial disc.

    Science.gov (United States)

    Coric, Domagoj; Guyer, Richard D; Nunley, Pierce D; Musante, David; Carmody, Cameron; Gordon, Charles; Lauryssen, Carl; Boltes, Margaret O; Ohnmeiss, Donna D

    2018-03-01

    OBJECTIVE Seven cervical total disc replacement (TDR) devices have received FDA approval since 2006. These devices represent a heterogeneous assortment of implants made from various biomaterials with different biomechanical properties. The majority of these devices are composed of metallic endplates with a polymer core. In this prospective, randomized multicenter study, the authors evaluate the safety and efficacy of a metal-on-metal (MoM) TDR (Kineflex|C) versus anterior cervical discectomy and fusion (ACDF) in the treatment of single-level spondylosis with radiculopathy through a long-term (5-year) follow-up. METHODS An FDA-regulated investigational device exemption (IDE) pivotal trial was conducted at 21 centers across the United States. Standard validated outcome measures including the Neck Disability Index (NDI) and visual analog scale (VAS) for assessing pain were used. Patients were randomized to undergo TDR using the Kineflex|C cervical artificial disc or anterior cervical fusion using structural allograft and an anterior plate. Patients were evaluated preoperatively and at 6 weeks and 3, 6, 12, 24, 36, 48, and 60 months after surgery. Serum ion analysis was performed on a subset of patients randomized to receive the MoM TDR. RESULTS A total of 269 patients were enrolled and randomly assigned to undergo either TDR (136 patients) or ACDF (133 patients). There were no significant differences between the TDR and ACDF groups in terms of operative time, blood loss, or length of hospital stay. In both groups, the mean NDI scores improved significantly by 6 weeks after surgery and remained significantly improved throughout the 60-month follow-up (both p < 0.01). Similarly, VAS pain scores improved significantly by 6 weeks and remained significantly improved through the 60-month follow-up (both p < 0.01). There were no significant changes in outcomes between the 24- and 60-month follow-ups in either group. Range of motion in the TDR group decreased at 3 months but

  3. Early Results of a Modular Cementless Tibial Component for Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Raj Sinha, MD, PhD

    2014-10-01

    Full Text Available Cementless components in TKA have been used for almost 3 decades, despite mixed success rates. However, biologic fixation remains attractive, especially for younger patients, because of the potential of unlimited durability. This paper is the first to report results on a modular tibial base plate using trabecular metal as a fixation surface. Twenty-four primary TKAs were evaluated clinical and radiographically at mean 1.9 year followup. Excellent clinical results were obtained. There was no significant subsidence or change in orientation of any component. One component was probably loose radiographically but was insufficiently symptomatic to warrant revision. Five components showed nonprogressive radiolucent lines. One reoperation was performed for stiffness, at which time the components were well fixed. Thus, it would appear that excellent bony fixation can be achieved with a modular cementless tibial component with excellent short-term clinical results.

  4. Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

    Directory of Open Access Journals (Sweden)

    Gholam Hossein Shahcheraghi

    2015-09-01

    Full Text Available Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations. Methods: 52 primary cementless total hip arthroplasty in 42 patients with the mean age of 48.8 years were retrospectively studied. Two groups of prosthesis had been implanted: Harris-Galante II (HGII in 15 and Versys-Trilogy (V-T in 37 hips, both from Zimmer company. The patients were assessed clinically, radiographically and with Harris hip score, SF36, WOMAC, and MACTAR questionnaires, with 65 months (26-136 mean follow-up. Results: All the V-T prostheses had survived well. Eight of HG II were revised by the last follow-up in 19-102 months. All had undergone acetabular revision and 2 combined with femoral revision. Broken tines of HGII cups were seen in 4 radiographs. The 65 months overall survival was 96.2% for femoral and 84.6% for acetabular components. 90% had good or excellent Harris hip scores. The functional scores were poorer in the HG II group. Pain relief and improved walking were the two main patients’ expectations fulfilled in 97.6% and 92.8%, respectively. Conclusions: The outcome of cementless total hip arthroplasty (THA is satisfactory and comparable with the literature based on the results of function and survival of this small comparative group. The use of HGII acetabular component should be abandoned.

  5. Long-term result of cementless femoral stem in avascular necrosis of the hip.

    Science.gov (United States)

    Cheung, Kin W; Chiu, Kwok H; Chung, Kwong Y

    2015-01-01

    Avascular necrosis (AVN) of the hip may have extensive involvement of the proximal femur which may affect boney ingrowth into cementless femoral stems. From 1994 to 2004, 182 total hip arthroplasties (in 144 patients, 117 AVN hips and 65 non-AVN hips) were performed using hydroxyapatite coated femoral stems. All patients were followed up prospectively. Mean age was 51 years and mean follow-up 14.7 years (range 9.7-19.1 years). Four stems were revised because of aseptic loosening, 3 in AVN group and 1 in non-AVN group. The overall mechanical failure rate was 2.2%, the mechanical failure rate in AVN and non-AVN group was 2.6% and 1.5% respectively (p = 1). The 19.1 year survival using revision for aseptic loosening as an endpoint for AVN and non-AVN patients were 97.1% and 96.2% respectively (p = 0.654). Stable boney ingrowth was present in 99.5% hips. This study represents 1 of the largest series reporting the long-term follow-up of the use of cementless femoral stems in treating AVN of the hip. We report excellent long-term survival of cementless total hip arthroplasty used in managing AVN of the hip and is comparable to that seen in non-AVN total hip arthroplasty.

  6. Femoral head fracture without hip dislocation

    Directory of Open Access Journals (Sweden)

    Aggarwal Aditya K

    2013-10-01

    Full Text Available 【Abstract】Femoral head fractures without dislocation or subluxation are extremely rare injuries. We report a neglected case of isolated comminuted fracture of femoral head without hip dislocation or subluxation of one year duration in a 36-year-old patient who sustained a high en- ergy trauma due to road traffic accident. He presented with painful right hip and inability to bear full weight on right lower limb with Harris hip score of 39. He received cementless total hip replacement. At latest follow-up of 2.3 years, functional outcome was excellent with Harris hip score of 95. Such isolated injuries have been described only once in the literature and have not been classified till now. The purpose of this report is to highlight the extreme rarity, possible mechanism involved and a novel classification system to classify such injuries. Key words: Femur head; Hip dislocation; Classification; Arthroplasty, replacement, hip

  7. Fixation of Trochanteric Fragments in Cementless Bipolar Hemiarthroplasty of Unstable Intertrochanteric Fracture: Cerclage Wiring.

    Science.gov (United States)

    Lee, Young-Kyun; Park, Chan Ho; Koo, Kyung-Hoi

    2017-12-01

    Bipolar hemiarthroplasty (HA) is an option for the treatment of unstable intertrochanteric fracture in elderly patients. There is a raising concern regarding cable-grip related complications for the fixation of trochanteric fragments. Therefore, the aim of this study was to evaluate outcome of cementless HA with fixation for the trochanteric fragments using monofilament wires in unstable intertrochanteric fracture. We reviewed 92 cementless bipolar HAs using a grit-blasted long stem design for unstable intertrochanteric fractures in 91 elderly patients with a mean age of 81.7 years. During the arthroplasty, trochanteric fracture fragments were fixed using 1 or 2 vertical wires and transverse wires. We evaluated the clinical outcomes such as abductor power, ambulatory ability and wire-related complications, and radiologic outcomes including the union of the trochanteric fragment and subsidence of stem. Sixty-two patients were followed for a minimum of 2 years (mean, 59 months) postoperatively. The mean abductor power and Koval category was 4.1 (range, 3 to 5) and 4.6 (range, 1 to 6). The wire was broken in 3 hips (4.8%) and the nonunion of the greater trochanter occurred in 1 hips (1.6%). Two stems subsided by 3 mm and 8 mm, respectively, during postoperative 6 weeks, after which the subsidence was not progressive. Cerclage wiring of the trochanter using monofilament wire leads to acceptable outcome in cementless HA for senile patients with unstable intertrochanteric fracture. Cerclage wiring using a monofilament wire is recommended for the fixation of trochanteric fragments.

  8. Does osteoporosis reduce the primary tilting stability of cementless acetabular cups?

    Science.gov (United States)

    von Schulze Pellengahr, Christoph; von Engelhardt, Lars V; Wegener, Bernd; Müller, Peter E; Fottner, Andreas; Weber, Patrick; Ackermann, Ole; Lahner, Matthias; Teske, Wolfram

    2015-04-21

    Cementless hip cups need sufficient primary tilting stability to achieve osseointegration. The aim of the study was to assess differences of the primary implant stability in osteoporotic bone and in bone with normal bone density. To assess the influence of different cup designs, two types of threaded and two types of press-fit cups were tested. The maximum tilting moment for two different cementless threaded cups and two different cementless press-fit cups was determined in macerated human hip acetabuli with reduced (n=20) and normal bone density (n=20), determined using Q-CT. The tilting moments for each cup were determined five times in the group with reduced bone density and five times in the group with normal bone density, and the respective average values were calculated. The mean maximum extrusion force of the threaded cup Zintra was 5670.5 N (max. tilting moment 141.8 Nm) in bone with normal density and.5748.3 N (max. tilting moment 143.7 Nm) in osteoporotic bone. For the Hofer Imhof (HI) threaded cup it was 7681.5 N (192.0 Nm) in bone with normal density and 6828.9 N (max. tilting moment 170.7 Nm) in the group with osteoporotic bone. The mean maximum extrusion force of the macro-textured press-fit cup Metallsockel CL was 3824.6 N (max. tilting moment 95.6 Nm) in bone with normal and 2246.2 N (max. tilting moment 56.2 Nm) in osteoporotic bone. For the Monoblock it was 1303.8 N (max. tilting moment 32.6 Nm) in normal and 1317 N (max. tilting moment 32.9 Nm) in osteoporotic bone. There was no significance. A reduction of the maximum tilting moment in osteoporotic bone of the ESKA press-fit cup Metallsockel CL was noticed. Results on macerated bone specimens showed no statistically significant reduction of the maximum tilting moment in specimens with osteoporotic bone density compared to normal bone, neither for threaded nor for the press-fit cups. With the limitation that the results were obtained using macerated bone, we could not detect any restrictions for

  9. Antibacterial Efficacy of a New Gentamicin-Coating for Cementless Prostheses Compared to Gentamicin-Loaded Bone Cement

    NARCIS (Netherlands)

    Neut, Danielle; Dijkstra, Rene J. B.; Thompson, Jonathan I.; van der Mei, Henny C.; Busscher, Henk J.

    Cementless prostheses are increasingly popular but require alternative prophylactic measures than the use of antibiotic-loaded bone cements. Here, we determine the 24-h growth inhibition of gentamicin-releasing coatings from grit-blasted and porous-coated titanium alloys, and compare their

  10. Digital tomosynthesis with metal artifact reduction for assessing cementless hip arthroplasty: a diagnostic cohort study of 48 patients

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Hao; Yang, Dejin; Guo, Shengjie; Tang, Jing; Liu, Jian; Wang, Dacheng; Zhou, Yixin [Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Department of Orthopaedic Surgery, Beijing (China)

    2016-11-15

    For postoperative imaging assessment of cementless hip arthroplasty, radiography and computed tomography (CT) were restricted by overlapping structures and metal artifacts, respectively. A new tomosynthesis with metal artifact reduction (TMAR) is introduced by using metal extraction and ordered subset-expectation maximization (OS-EM) reconstruction. This study investigated the effectiveness of TMAR in assessing fixation stability of cementless hip arthroplasty components. We prospectively included 48 consecutive patients scheduled for revision hip arthroplasty in our hospital, with 41 femoral and 35 acetabular cementless components available for evaluation. All patients took the three examinations of radiography, CT, and TMAR preoperatively, with intraoperative mechanical tests, and absence or presence of osteointegration on retrieved prosthesis as reference standards. Three senior surgeons and four junior surgeons evaluated these images independently with uniform criteria. For TMAR, 82 % diagnoses on the femoral side and 84 % diagnoses on the acetabular side were accurate. The corresponding values were 44 and 67 % for radiography, and 39 % and 74 % for CT. Senior surgeons had significantly higher accuracy than junior surgeons by radiography (p < 0.05), but not by TMAR or CT. By minimizing metal artifacts in the bone-implant interface and clearly depicting peri-implant trabecular structures, the TMAR technique improved the diagnostic accuracy of assessing fixation stability of cementless hip arthroplasty, and shortened the learning curve of less experienced surgeons. Level II, diagnostic cohort study. (orig.)

  11. Preclinical trial of a novel surface architecture for improved primary fixation of cementless orthopaedic implants.

    Science.gov (United States)

    Harrison, Noel; Field, John R; Quondamatteo, Fabio; Curtin, William; McHugh, Peter E; Mc Donnell, Pat

    2014-09-01

    A new surface architecture for cementless orthopaedic implants (OsteoAnchor), which incorporates a multitude of tiny anchor features for enhancing primary fixation, was tested in an ovine hemi-arthroplasty pilot study. Test animals were implanted with a hip stem component incorporating the OsteoAnchor surface architecture produced using additive layer manufacturing and control animals were implanted with stems containing a standard plasma sprayed titanium coating. Intra-operative surgeon feedback indicated that superior primary fixation was achieved for the OsteoAnchor stems and rapid return to normal gait and load bearing was observed post-operation. Following a 16-week recovery time, histological evaluation of the excised femurs revealed in-growth of healthy bone into the porous structure of the OsteoAnchor stems. Bone in-growth was not achieved for the plasma sprayed stems. These results indicate the potential for the OsteoAnchor surface architecture to enhance both the initial stability and long term lifetime of cementless orthopaedic implants. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Influence of different sizes of composite femora on the biomechanical behavior of cementless hip prosthesis.

    Science.gov (United States)

    Schmidutz, Florian; Woiczinski, Mathias; Kistler, Manuel; Schröder, Christian; Jansson, Volkmar; Fottner, Andreas

    2017-01-01

    For the biomechanical evaluation of cementless stems different sizes of composite femurs have been used in the literature. However, the impact of different specimen sizes on test results is unknown. To determine the potential effect of femur size the biomechanical properties of a conventional stem (CLS Spotorno) were examined in 3 different sizes (small, medium and large composite Sawbones®). Primary stability was tested under physiologically adapted dynamic loading conditions measuring 3-dimensional micromotions. For the small composite femur the dynamic load needed to be adapted since fractures occurred when reaching 1700N. Additionally, surface strain distribution was recorded before and after implantation to draw conclusions about the tendency for stress shielding. All tested sizes revealed similar micromotions only reaching a significant different level at one measurement point. The highest micromotions were observed at the tip of the stems exceeding the limit for osseous integration of 150μm. Regarding strain distribution the highest strain reduction after implantation was registered in all sizes at the level of the lesser trochanter. Specimen size seems to be a minor influence factor for biomechanical evaluation of cementless stems. However, the small composite femur is less suitable for biomechanical testing since this size failed under physiological adapted loads. For the CLS Spotorno osseous integration is unlikely at the tip of the stem and the tendency for stress shielding is the highest at the level of the lesser trochanter. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Ideal femoral head size in total hip arthroplasty balances stability and volumetric wear.

    Science.gov (United States)

    Cross, Michael B; Nam, Denis; Mayman, David J

    2012-10-01

    Over the last several years, a trend towards increasing femoral head size in total hip arthroplasty to improve stability and impingement free range of motion has been observed. The specific questions we sought to answer in our review were: (1) What are the potential advantages and disadvantages of metal-on-metal, ceramic-on-ceramic, and metal-on-polyethylene bearings? (2) What is effect that femoral head size has on joint kinematics? (3) What is the effect that large femoral heads have on bearing surface wear? A PubMed search and a review of 2012 Orthopaedic Research Society abstracts was performed and articles were chosen that directly answered components of the specific aims and that reported outcomes with contemporary implant designs or materials. A review of the literature suggests that increasing femoral head size decreases the risk of postoperative dislocation and improves impingement free range of motion; however, volumetric wear increases with large femoral heads on polyethylene and increases corrosion of the stem in large metal-on-metal modular total hip arthroplasty (THA); however, the risk of potentially developing osteolysis or adverse reactions to metal debris respectively is still unknown. Further, the effect of large femoral heads with ceramic-on-ceramic THA is unclear, due to limited availability and published data. Surgeons must balance the benefits of larger head size with the increased risk of volumetric wear when determining the appropriate head size for a given patient.

  14. Do screws and screw holes affect osteolysis in cementless cups using highly crosslinked polyethylene? A 7 to 10-year follow-up case-control study.

    Science.gov (United States)

    Taniguchi, N; Jinno, T; Takada, R; Koga, D; Ando, T; Okawa, A; Haro, H

    2018-05-01

    The use of screws and the presence of screw holes may cause acetabular osteolysis and implant loosening in cementless total hip arthroplasty (THA) using conventional polyethylene. In contrast, this issue is not fully understood using highly crosslinked polyethylene (HXLPE), particularly in large comparative study. Therefore, we performed a case-control study to assess the influence of screw usage and screw holes on: (1) implant fixation and osteolysis and (2) polyethylene steady-state wear rate, using cases with HXLPE liners followed up for 7-10 years postoperatively. The screw usage and screw holes adversely affect the implant fixation and incidence of wear-related osteolysis in THA with HXLPE. We reviewed 209 primary cementless THAs performed with 26-mm cobalt-chromium heads on HXLPE liners. To compare the effects of the use of screws and the presence of screw holes, the following groups were established: (1) with-screw (n=140); (2) without-screw (n=69); (3) no-hole (n=27) and (4) group in which a cup with screw holes, but no screw was used (n=42). Two adjunct groups (no-hole cups excluded) were established to compare the differences in the two types of HXLPE: (5) remelted group (n=100) and (6) annealed group (n=82). Implant stability and osteolysis were evaluated by plain radiography and computed tomography. The wear rate from 1 year to the final evaluation was measured using plain X-rays and PolyWare Digital software. All cups and stems achieved bony fixation. On CT-scan, no acetabular osteolysis was found, but there were 3 cases with a small area of femoral osteolysis. The mean steady-state wear rate of each group was (1) 0.031±0.022, (2) 0.033±0.035, (3) 0.031±0.024, (4) 0.029±0.018, (5) 0.030±0.018 and (6) 0.034±0.023mm/year, respectively. A comparison of the effects of screw usage or screw holes found no significant between-group differences in the implant stability, prevalence of osteolysis [no acetabular osteolysis and 3/209 at femoral side (1

  15. Utilizing of the metallurgical slag for production of cementless concrete mixtures

    Directory of Open Access Journals (Sweden)

    D. Baricová

    2012-10-01

    Full Text Available In process of pig iron, steel and cast iron production besides main product, also secondary products are formed, that have character of secondary raw materials and industrial wastes. The most abundant secondary product originating in the metallurgical process is furnace slag. Total amount of accured slag, also its chemical, mineralogical, physical – chemical properties and similarity with natural stones predestinate its utilisation in different fields of industry. The contribution deals with production of cementless concrete mixtures, where the main parts were formed by blast furnace granulated slag grinded and different gravel slag from blast furnace, oxygen converter and electric arc furnace. As activators of solidification different kinds of water glass were tested.

  16. Osseointegration: a review of the fundamentals for assuring cementless skeletal fixation

    Directory of Open Access Journals (Sweden)

    Isaacson BM

    2014-04-01

    Full Text Available Brad M Isaacson,1,2 Sujee Jeyapalina3,4 1Henry M Jackson Foundation for the Advancement of Military Medicine, 2The Center for Rehabilitation Sciences Research, Department of Physical Medicine and Rehabilitation, Uniformed Services University of Health Sciences, Bethesda, MD, USA; 3Department of Orthopedics, 4Orthopedic Research Laboratory, University of Utah, Salt Lake City, UT, USA Abstract: Direct skeletal fixation, termed osseointegration, has expanded in the last century and includes use in total joint replacements, the edentulous mandible and maxilla, and percutaneous osseointegrated prosthetics. Although it is well known that titanium and bone have the ability to form a durable bone–implant interface, new applications have emerged in the field of orthopedics, which requires a more thorough assessment of the literature. This review aims to introduce the basic biological principles for attaining osseointegration and discusses the major factors for assuring successful cementless fixation. Keywords: osseointegration, bone, skeletal attachment, total joint replacements, dental implants, percutaneous

  17. Subsidence of a cementless femoral component influenced by body weight and body mass index.

    Science.gov (United States)

    Stihsen, Christoph; Radl, Roman; Keshmiri, Armin; Rehak, Peter; Windhager, Reinhard

    2012-05-01

    This trial was designed to evaluate the impact of physical characteristics such as body mass index, body weight and height on distal stem migration of a cementless femoral component, as the influence of obesity on the outcome of THA is still debated in literature and conflicting results have been found. In this retrospective cohort study, migration patterns for 102 implants were analysed using the Einzel-Bild-Roentgen-Analyse (EBRA-FCA, femoral component analysis). In all cases the Vision 2000 stem was implanted and combined with the Duraloc acetabular component (DePuy, Warsaw, Indiana). The mean follow-up was 93 months. EBRA-FCA evaluations revealed a mean subsidence of 1.38 mm after two years, 2.06 mm after five and 2.24 mm after seven years. Five stems loosened aseptically. Correlation between increased migration over the whole period and aseptic loosening was highly significant (p < 0.001). Surgical technique had a significant influence on migration and stem stability (p = 0.002) but physical patient characteristics such as body weight over 75 kg and height over 165 cm also significantly influenced stem subsidence towards progressive migration (p = 0.001, p < 0.001). However, a high BMI did not trigger progressive stem migration (p = 0.87). Being of the male gender raised the odds for increased migration (p = 0.03). Physical characteristics such as body weight and height showed significant influence on migration patterns of this cementless femoral component. The operating surgeon should be aware that body weight above 75 kg and height over 165 cm may trigger increased stem migration and the surgeon should aim to fit these prostheses as tightly as possible. However this study demonstrates that a high BMI does not trigger progressive stem migration. Further investigations are needed to confirm our findings.

  18. [First clinical experiences with a new cementless knee endoprosthesis for the dog].

    Science.gov (United States)

    Behrend, A; Bonin, T; Hach, V

    2013-01-01

    This paper reports on the clinical application and first experiences of a newly developed cementless knee endoprosthesis for dogs. The GenuSys knee-endoprosthesis was implanted in 23 knees of 22 dogs with severe gonarthritis and a history of pain. Their body weight ranged from 28 to 55 kg, their age between 5 and 12 years. This knee implant for dogs is a cementless "mobile bearing prosthesis". An additional fixation with one screw is necessary in the femoral component. Currently, there are four standard sizes of the prosthesis available. At the end of the study, 16 of 22 controlled patients (72.7%) were fully weightbearing on the operated limb or only showed a discreet lameness. We observed no complications in 12 cases (54.5%). In 10 cases problems in the course of healing were detected and made or would have made reoperation necessary. The complications noted were subluxation (n = 6, 27.3%), wound infection (n = 3, 13.6%) and a serious decrease in the range of motion (n = 1, 4.5%). Four of these 10 patients (40%) were subsequently healed through surgery. The remaining six dogs (27.3%) were euthanized or underwent arthrodesis of the leg. Sixteen of 22 dogs (72.2%) showed much better weightbearing and an increased quality of life after endoprosthesis of the knee. Although the complication rate was high, we expect better results in the future due to improvements in the equipment and surgical procedure. A definitive conclusion can only be made based on the results of a long-term study.

  19. A biodegradable gentamicin-hydroxyapatite-coating for infection prophylaxis in cementless hip prostheses

    Directory of Open Access Journals (Sweden)

    D Neut

    2015-01-01

    Full Text Available A degradable, poly (lactic-co-glycolic acid (PLGA, gentamicin-loaded prophylactic coating for hydroxyapatite (HA-coated cementless hip prostheses is developed with similar antibacterial efficacy as offered by gentamicin-loaded cements for fixing traditional, cemented prostheses in bone. We describe the development pathway, from in vitro investigation of antibiotic release and antibacterial properties of this PLGA-gentamicin-HA-coating in different in vitro models to an evaluation of its efficacy in preventing implant-related infection in rabbits. Bone in-growth in the absence and presence of the coating was investigated in a canine model. The PLGA-gentamicin-HA-coating showed high-burst release, with antibacterial efficacy in agar-assays completely disappearing after 4 days, minimising risk of inducing antibiotic resistance. Gentamicin-sensitive and gentamicin-resistant staphylococci were killed by the antibiotic-loaded coating, in a simulated prosthesis-related interfacial gap. PLGA-gentamicin-HA-coatings prevented growth of bioluminescent staphylococci around a miniature-stem mounted in bacterially contaminated agar, as observed using bio-optical imaging. PLGA-gentamicin-HA-coated pins inserted in bacterially contaminated medullary canals in rabbits caused a statistically significant reduction in infection rates compared to HA-coated pins without gentamicin. Bone ingrowth to PLGA-gentamicin-HA-coated pins, in condylar defects of Beagle dogs was not impaired by the presence of the degradable, gentamicin-loaded coating. In conclusion, the PLGA-gentamicin-HA-coating constitutes an effective strategy for infection prophylaxis in cementless prostheses.

  20. Cementless Hip Stem Anteversion in the Dysplastic Hip: A Comparison of Tapered Wedge vs Metaphyseal Filling.

    Science.gov (United States)

    Taniguchi, Naofumi; Jinno, Tetsuya; Koga, Daisuke; Hagino, Tetsuo; Okawa, Atsushi; Haro, Hirotaka

    2017-05-01

    Appropriate stem anteversion is important for achieving stability of the prosthetic joint in total hip arthroplasty. Anteversion of a cementless femoral stem is affected by the femoral canal morphology and varies according to stem geometry. We investigated the difference and variation of the increase in anteversion between 2 types of cementless stems, and the correlation between each stem and the preoperative femoral anteversion. We retrospectively compared 2 groups of hips that underwent total hip arthroplasty using a metaphyseal filling stem (78 hips) or a tapered wedge stem (83 hips). All the patients had osteoarthritis due to hip dysplasia. Computed tomography was used to measure preoperative femoral anteversion at 5 levels and postoperative stem anteversion. The increase in anteversion of the tapered wedge stem group (22.7° ± 11.6°) was more than that of the metaphyseal filling stem group (17.2° ± 8.3°; P = .0007). The variation of the increase in the tapered wedge stem group was significantly larger than that in the metaphyseal filling stem group (P = .0016). The metaphyseal filling stem group was more highly and positively correlated with femoral anteversion than the tapered wedge stem group. Femoral anteversion affects stem anteversion differently according to stem geometry. The tapered wedge stems had greater variation of the increase in anteversion than did the metaphyseal filling stems. Based on the results of this study, it is difficult to preoperatively estimate the increase in stem anteversion for tapered wedge stems. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Migration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Zilkens C

    2011-03-01

    Full Text Available Abstract The aim of this study was to evaluate the initial acetabular implant stability and late acetabular implant migration in press fit cups combined with screw fixation of the acetabular component in order to answer the question whether screws are necessary for the fixation of the acetabular component in cementless primary total hip arthroplasty. One hundred and seven hips were available for follow-up after primary THA using a cementless, porous-coated acetabular component. A total of 631 standardized radiographs were analyzed digitally by the "single-film-x-ray-analysis" method (EBRA. One hundred 'and one (94.4% acetabular components did not show significant migration of more than 1 mm. Six (5.6% implants showed migration of more than 1 mm. Statistical analysis did not reveal preoperative patterns that would identify predictors for future migration. Our findings suggest that the use of screw fixation for cementless porous- coated acetabular components for primary THA does not prevent cup migration.

  2. Design optimization of cementless metal-backed cup prostheses using the concept of functionally graded material

    Energy Technology Data Exchange (ETDEWEB)

    Hedia, H S; El-Midany, T T; Shabara, M A N; Fouda, N [Production Engineering and M/C Design Department, Faculty of Engineering, Mansoura University, Mansoura (Egypt)

    2006-09-15

    Metal backing has been widely used in acetabular cup design. A stiff backing for a polyethylene liner was initially believed to be mechanically favourable. Yet, recent studies of the load transfer around acetabular cups have shown that a stiff backing causes two problems. It generates higher stress peaks around the acetabular rim than those caused by full polyethylene cups and reduces the stresses transferred to the dome of the acetabulum causing stress shielding. The aim of this study is to overcome these two problems by improving the design of cementless metal-backed acetabular cups using the two-dimensional functionally graded material (FGM) concept through finite-element analysis and optimization techniques. It is found that the optimal 2D FGM model must have three bioactive materials of hydroxyapatite, Bioglass and collagen. This optimal material reduces the stress shielding at the dome of the acetabulum by 40% and 37% compared with stainless steel and titanium metal backing shells, respectively. In addition, using the 2D FGM model reduces the maximum interface shear stress in the bone by 31% compared to the titanium metal backing shell.

  3. The impact of subsidence on straight and curved modular cementless revision stems in hip revision surgery.

    Science.gov (United States)

    Fraile Suari, A; Gil González, S; Pérez Prieto, D; León García, A; Mestre Cortadellas, C; Tey Pons, M; Marqués López, F

    Subsidence is one of the potential complications in femoral stem revision total hip arthroplasty surgery, and can affect stability and osseointegration. A retrospective study was conducted on the outcomes at one year and 5 years (specifically subsidence and clinical relevance) of 40 consecutive femoral total hip arthroplasty revisions, comparing two modular cementless revision stems, Straight vs. Curved, with 20 patients in each group. No mechanical failure was observed, and there was an improvement in functional outcomes. Mean radiological subsidence was 9.9±4.9mm (straight=10.75mm vs. curved=9.03mm), with no statistically significant difference between groups (p=0,076). Fourteen patients (35%) had ≥10mm of subsidence, up to a maximum of 22mm. The subsidence found in this study is similar to published series, with no short-term clinical manifestations, or an increased number of complications or stem loosening in either the Straight or Curved group. No differences in subsidence were observed at one year and 5 years after surgery between the 2 types of stems. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Acceleration of Intended Pozzolanic Reaction under Initial Thermal Treatment for Developing Cementless Fly Ash Based Mortar

    Directory of Open Access Journals (Sweden)

    Yang-Hee Kwon

    2017-02-01

    Full Text Available Without using strong alkaline solution or ordinary Portland cement, a new structural binder consisting of fly ash and hydrated lime was hardened through an intensified pozzolanic reaction. The main experimental variables are the addition of silica fume and initial thermal treatment (60 °C for 3 days. A series of experiments consisting of mechanical testing (compressive and flexural strength, modulus of elasticity, X-ray diffraction, and measurements of the heat of hydration, pore structure, and shrinkage were conducted. These tests show that this new fly ash-based mortar has a compressive strength of 15 MPa at 91 days without any silica fume addition or initial thermal treatment. The strength increased to over 50 MPa based on the acceleration of the intensified pozzolanic reaction from the silica fume addition and initial thermal treatment. This is explained by a significant synergistic effect induced by the silica fume. It intensifies the pozzolanic reaction under thermal treatment and provides a space filling effect. This improved material performance can open a new pathway to utilize the industrial by-product of fly ash in cementless construction materials.

  5. Influence of undersized cementless hip stems on primary stability and strain distribution.

    Science.gov (United States)

    Fottner, Andreas; Woiczinski, Matthias; Kistler, Manuel; Schröder, Christian; Schmidutz, Tobias F; Jansson, Volkmar; Schmidutz, Florian

    2017-10-01

    Undersizing of cementless hip stems is a risk factor for aseptic loosening and early subsidence. The purpose of this study was to evaluate the effects of undersized stems and determine whether a biomechanical study can predict the clinical results. Three consecutive sizes of a clinically proven stem (CLS Spotorno) were implanted into six composite femora (size large, Sawbones ® ), respectively. According to the Canal Fill Index (CFI), two stems (size 11.25 and 12.5) were undersized (CFI  80%). The primary stability was evaluated by measurement of 3-dimensional (3D)-micromotions under physiological adapted load and surface strains were recorded before and after implantation to detect stress-shielding processes. Both undersized stems revealed significantly higher micromotions in all regions compared to the appropriate stem. The highest micromotions were registered at the distal tip of the three stem sizes. The changes in surface strain did not show a significant difference between the three stem sizes, but the highest strain reduction was observed proximally indicating a tendency for stress shielding. This study confirms the clinical assumption that undersized stem result in a significantly reduced primary stability. Furthermore, in vitro studies allow to determine the effects of undersizing and stress shielding processes.

  6. A Multicenter Approach Evaluating the Impact of Vitamin E-Blended Polyethylene in Cementless Total Hip Replacement

    Science.gov (United States)

    Jäger, Marcus; van Wasen, Andrea; Warwas, Sebastian; Landgraeber, Stefan; Haversath, Marcel; Group, VITAS

    2014-01-01

    Since polyethylene is one of the most frequently used biomaterials as a liner in total hip arthroplasty, strong efforts have been made to improve design and material properties over the last 50 years. Antioxidants seems to be a promising alternative to further increase durability and reduce polyethylene wear in long term. As of yet, only in vitro results are available. While they are promising, there is yet no clinical evidence that the new material shows these advantages in vivo. To answer the question if vitamin-E enhanced ultra-high molecular weight polyethylene (UHMWPE) is able to improve long-term survivorship of cementless total hip arthroplasty we initiated a randomized long-term multicenter trial. Designed as a superiority study, the oxidation index assessed in retrieval analyses of explanted liners was chosen as primary parameter. Radiographic results (wear rate, osteolysis, radiolucency) and functional outcome (Harris Hip Scores, University of California-Los Angeles, Hip Disability and Osteoarthritis Outcome Score, Visual Analogue Scale) will serve as secondary parameters. Patients with the indication for a cementless total hip arthroplasty will be asked to participate in the study and will be randomized to either receive a standard hip replacement with a highly cross-linked UHMWPE-X liner or a highly cross-linked vitamin-E supplemented UHMWPE-XE liner. The follow-up will be 15 years, with evaluation after 5, 10 and 15 years. The controlled randomized study has been designed to determine if Vitamin-E supplemented highly cross-linked polyethylene liners are superior to standard XLPE liners in cementless total hip arthroplasty. While several studies have been started to evaluate the influence of vitamin-E, most of them evaluate wear rates and functional results. The approach used for this multicenter study, to analyze the oxidation status of retrieved implants, should make it possible to directly evaluate the ageing process and development of the implant

  7. A multicenter approach evaluating the impact of vitamin E-blended polyethylene in cementless total hip replacement

    Directory of Open Access Journals (Sweden)

    Marcus Jäger

    2014-04-01

    Full Text Available Since polyethylene is one of the most frequently used biomaterials as a liner in total hip arthroplasty, strong efforts have been made to improve design and material properties over the last 50 years. Antioxidants seems to be a promising alternative to further increase durability and reduce polyethylene wear in long term. As of yet, only in vitro results are available. While they are promising, there is yet no clinical evidence that the new material shows these advantages in vivo. To answer the question if vitamin-E enhanced ultra-high molecular weight polyethylene (UHMWPE is able to improve long-term survivorship of cementless total hip arthroplasty we initiated a randomized long-term multicenter trial. Designed as a superiority study, the oxidation index assessed in retrieval analyses of explanted liners was chosen as primary parameter. Radiographic results (wear rate, osteolysis, radiolucency and functional outcome (Harris Hip Scores, University of California-Los Angeles, Hip Disability and Osteoarthritis Outcome Score, Visual Analogue Scale will serve as secondary parameters. Patients with the indication for a cementless total hip arthroplasty will be asked to participate in the study and will be randomized to either receive a standard hip replacement with a highly cross-linked UHMWPE-X liner or a highly cross-linked vitamin-E supplemented UHMWPE-XE liner. The follow-up will be 15 years, with evaluation after 5, 10 and 15 years. The controlled randomized study has been designed to determine if Vitamin-E supplemented highly cross-linked polyethylene liners are superior to standard XLPE liners in cementless total hip arthroplasty. While several studies have been started to evaluate the influence of vitamin-E, most of them evaluate wear rates and functional results. The approach used for this multicenter study, to analyze the oxidation status of retrieved implants, should make it possible to directly evaluate the ageing process and development

  8. Stable Fixation of a Cementless, Proximally Coated, Double Wedged, Double Tapered Femoral Stem in Total Hip Arthroplasty

    DEFF Research Database (Denmark)

    Nebergall, Audrey K; Rolfson, Ola; Rubash, Harry E

    2016-01-01

    BACKGROUND: The objective of this 5-year prospective study of 51 hips was to assess migration of a cementless tapered femoral stem using radiostereometric analysis (RSA), plain radiographs (radiolucencies), and patient-reported outcome measures (PROMs). METHODS: Forty-seven patients (51 hips...... year remain stable at 5 years. RSA was the most sensitive method of detection for stems at greater risk for potential future failure. This report adds contributions to the positive results associated with this type of fixation. The results at 5 years showed excellent midterm survivorship in this cohort...

  9. CoCr wear particles generated from CoCr alloy metal-on-metal hip replacements, and cobalt ions stimulate apoptosis and expression of general toxicology-related genes in monocyte-like U937 cells

    Energy Technology Data Exchange (ETDEWEB)

    Posada, Olga M., E-mail: O.M.PosadaEstefan@leeds.ac.uk [Biomedical Engineering Department, University of Strathclyde, Wolfson Centre, Glasgow G4 0NW (United Kingdom); Gilmour, Denise [Pure and Applied Chemistry Department, University of Strathclyde, Thomas Graham Building, Glasgow G1 1XL (United Kingdom); Tate, Rothwelle J., E-mail: r.j.tate@strath.ac.uk [Strathclyde Institute for Pharmacy and Biomedical Sciences, University of Strathclyde, Glasgow G4 0RE (United Kingdom); Grant, M. Helen [Biomedical Engineering Department, University of Strathclyde, Wolfson Centre, Glasgow G4 0NW (United Kingdom)

    2014-11-15

    Cobalt-chromium (CoCr) particles in the nanometre size range and their concomitant release of Co and Cr ions into the patients' circulation are produced by wear at the articulating surfaces of metal-on-metal (MoM) implants. This process is associated with inflammation, bone loss and implant loosening and led to the withdrawal from the market of the DePuy ASR™ MoM hip replacements in 2010. Ions released from CoCr particles derived from a resurfacing implant in vitro and their subsequent cellular up-take were measured by ICP-MS. Moreover, the ability of such metal debris and Co ions to induce both apoptosis was evaluated with both FACS and immunoblotting. qRT-PCR was used to assess the effects on the expression of lymphotoxin alpha (LTA), BCL2-associated athanogene (BAG1), nitric oxide synthase 2 inducible (NOS2), FBJ murine osteosarcoma viral oncogene homolog (FOS), growth arrest and DNA-damage-inducible alpha (GADD45A). ICP-MS showed that the wear debris released significant (p < 0.05) amounts of Co and Cr ions into the culture medium, and significant (p < 0.05) cellular uptake of both ions. There was also an increase (p < 0.05) in apoptosis after a 48 h exposure to wear debris. Analysis of qRT-PCR results found significant up-regulation (p < 0.05) particularly of NOS2 and BAG1 in Co pre-treated cells which were subsequently exposed to Co ions + debris. Metal debris was more effective as an inducer of apoptosis and gene expression when cells had been pre-treated with Co ions. This suggests that if a patient receives sequential bilateral CoCr implants, the second implant may be more likely to produce adverse effects than the first one. - Highlights: • Effects of CoCr nanoparticles and Co ions on U937 cells were investigated. • Ions released from wear debris play an important role in cellular response, • Toxicity of Co ions could be related to NO metabolic processes and apoptosis. • CoCr particles were a more effective inducer of apoptosis after cell

  10. Development of an acoustic measurement protocol to monitor acetabular implant fixation in cementless total hip Arthroplasty: A preliminary study.

    Science.gov (United States)

    Goossens, Quentin; Leuridan, Steven; Henyš, Petr; Roosen, Jorg; Pastrav, Leonard; Mulier, Michiel; Desmet, Wim; Denis, Kathleen; Vander Sloten, Jos

    2017-11-01

    In cementless total hip arthroplasty (THA), the initial stability is obtained by press-fitting the implant in the bone to allow osseointegration for a long term secondary stability. However, finding the insertion endpoint that corresponds to a proper initial stability is currently based on the tactile and auditory experiences of the orthopedic surgeon, which can be challenging. This study presents a novel real-time method based on acoustic signals to monitor the acetabular implant fixation in cementless total hip arthroplasty. Twelve acoustic in vitro experiments were performed on three types of bone models; a simple bone block model, an artificial pelvic model and a cadaveric model. A custom made beam was screwed onto the implant which functioned as a sound enhancer and insertor. At each insertion step an acoustic measurement was performed. A significant acoustic resonance frequency shift was observed during the insertion process for the different bone models; 250 Hz (35%, second bending mode) to 180 Hz (13%, fourth bending mode) for the artificial bone block models and 120 Hz (11%, eighth bending mode) for the artificial pelvis model. No significant frequency shift was observed during the cadaveric experiment due to a lack of implant fixation in this model. This novel diagnostic method shows the potential of using acoustic signals to monitor the implant seating during insertion. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  11. Heads Up

    Science.gov (United States)

    ... Connect with Us HEADS UP Apps Reshaping the Culture Around Concussion in Sports Get HEADS UP on Your Web Site Concussion ... HEADS UP on your web site! Create a culture of safety for young athletes Officials, learn how you can ... UP to Providers HEADS UP to Youth Sports HEADS UP to School Sports HEADS UP to ...

  12. Delayed cementless total hip arthroplasty for neglected dislocation of hip combined with complex acetabular fracture and deficient bone stock

    Directory of Open Access Journals (Sweden)

    Gavaskar Ashok S

    2012-12-01

    Full Text Available 【Abstract】Total hip arthroplasty (THA for an un-treated acetabular fracture is technically challenging and the long-term result is not so favorable. A 45-year-old fe-male patient with untreated column and comminuted poste-rior wall fracture of the acetabulum was treated in our insti-tution by reconstruction of the posterior wall using iliac strut autograft and plate stabilization of the posterior col-umn with cancellous grafting and cementless THA in a single stage. At 3 years’ follow-up, the patient was independently mobile without limb length discrepancy. Radiological evalu-ation showed well integrated components and bone grafts. No evidence of aseptic loosening or osteolysis was found. This report aims to emphasize that bony acetabular recon-struction allows the use of primary hip components, which improves prosthesis longevity and preserves bone stock for a future revision. Key words: Acetabulum; Fractures, bone; Hip dislocation; Arthroplasty, replacement, hip

  13. Do Rerevision Rates Differ After First-time Revision of Primary THA With a Cemented and Cementless Femoral Component?

    DEFF Research Database (Denmark)

    Gromov, Kirill; Pedersen, Alma B; Overgaard, Søren

    2015-01-01

    ) and 2 years (range, 0-16 years), respectively. Survival of first revision THA, with second revision of the femur as outcome, was evaluated using hazard ratios (HRs) with 95% confidence interval (CI) adjusting for potential confounding. All patient- and surgery-related data are collected from Danish...... for the most likely confounding factors. Our data suggest that increased use of cementless fixation in primary THA may lead to inferior survivorship of first revision THA. Level III, therapeutic study....... the results of future revision procedures; however, this has not been documented. The purpose of this study was to compare (1) the risk for rerevision of first revision THA; (2) the patterns of femoral bone loss at the time of first revision of primary THA; (3) the reasons for first revision of primary THA...

  14. Cementless Stem for Femoral Neck Fractures in a Patient's 10th Decade of Life: High Rate of Periprosthetic Fractures.

    Science.gov (United States)

    Kabelitz, Method; Fritz, Yannick; Grueninger, Patrick; Meier, Christoph; Fries, Patrick; Dietrich, Michael

    2018-01-01

    Subsidence of cementless femoral stems in hemiarthroplasty (HA) and increased fracture rates are ongoing concerns of orthopedic surgeons when treating fractures in very old patients. Additionally, bone cement implantation syndrome may result in perioperative cardiac or pulmonary complications, especially in older patients, leading to morbidity and mortality. This study was performed to analyze possible subsidence and intraoperative fractures in a cohort of very old patients treated with cementless stems. We retrospectively analyzed a consecutive cohort of patients aged ≥90 years with femoral neck fractures treated by uncemented HA and an anterior minimally invasive approach. Immediate full-weight bearing was allowed postoperatively. Pelvic radiographs were examined for subsidence immediately postoperatively and 6 weeks later. We treated 109 patients (74% women; mean age, 93 years; range, 90-102 years) by HA from January 2010 to March 2016. The 30-day mortality rate was 16%, and the morbidity rate was 47%. There were 11 (12%) intraoperative fractures: 8 (Vancouver B 2 ) had to be addressed immediately during the primary operation, while 3 (1 Vancouver B 1 and 2 Vancouver A G ) were treated conservatively. One periprosthetic femoral fracture (Vancouver B 1 ) was documented during follow-up. In 17 patients, subsidence of >2.0 mm (median, 3.9 mm; range, 2.5-9.0 mm) was documented. Early subsidence was low in this very old cohort treated with an uncemented stem and not showing a periprosthetic fracture. The risk of intraoperative periprosthetic fractures was high. The use of uncemented implants in osteoporotic bone continues to be an intervention with high risk and should only be performed by experienced surgeons. Level III, Therapeutic study.

  15. Primary stability of a cementless acetabular cup in a cohort of patient-specific finite element models.

    Science.gov (United States)

    O'Rourke, Dermot; Al-Dirini, Rami Ma; Taylor, Mark

    2018-03-01

    The primary stability achieved during total hip arthroplasty determines the long-term success of cementless acetabular cups. Pre-clinical finite element testing of cups typically use a model of a single patient and assume the results can be extrapolated to the general population. This study explored the variability in predicted primary stability of a Pinnacle ® cementless acetabular cup in 103 patient-specific finite element models of the hemipelvis and examined the association between patient-related factors and the observed variability. Cups were inserted by displacement-control into the FE models and then a loading configuration simulating a complete level gait cycle was applied. The cohort showed a range of polar gap of 284-1112 μm and 95th percentile composite peak micromotion (CPM) of 18-624 μm. Regression analysis was not conclusive on the relationship between patient-related factors and primary stability. No relationship was found between polar gap and micromotion. However, when the patient-related factors were categorised into quartile groups, trends suggested higher polar gaps occurred in subjects with small and shallow acetabular geometries and cup motion during gait was affected most by low elastic modulus and high bodyweight. The variation in primary stability in the cohort for an acetabular cup with a proven clinical track record may provide benchmark data when evaluating new cup designs. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1012-1023, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  16. In vitro osteogenic capacity of bone marrow MSCs from postmenopausal women reflect the osseointegration of their cementless hip stems

    Directory of Open Access Journals (Sweden)

    Jessica J. Alm

    2016-12-01

    Full Text Available Age-related dysfunction of mesenchymal stromal cells (MSCs is suggested as a main cause of altered bone repair with aging. We recently showed that in postmenopausal women undergoing cementless total hip arthroplasty (THA aging, low bone mineral density (BMD and age-related geometric changes of the proximal femur are risk factors for increased early migration and delayed osseointegration of the femoral stems. Extending these analyses, we have here explored how the in vitro osteogenic capacity of bone marrow MSCs from these patients reflects implant osseointegration, representing the patient's in vivo bone healing capacity. A total of 19 postmenopausal women with primary hip osteoarthritis (mean age 65 years, range 50–78 and well-defined bone quality underwent successful preoperative in vitro analysis of osteogenic capacity of iliac crest bone marrow MSCs as well as two-year radiostereometric (RSA follow-up of femoral stem migration after cementless THA. In patients with MSCs of low osteogenic capacity, the magnitude of cumulative stem subsidence after the settling period of three months was greater (p = 0.028 and the time point for translational osseointegration was significantly delayed (p = 0.030 compared to patients with MSCs of high osteogenic capacity. This study suggests that patients with MSCs of low in vitro osteogenic capacity may display increased stem subsidence after the settling period of 3 months and thereby delayed osseointegration. Our study presents a novel approach for studying the biological progress of hip implant osseointegration and to verify the impact of decreased MSCs function, especially in patients with age-related dysfunction of MSCs and bone healing capacity. Keywords: Human mesenchymal stromal cells, Osteogenic differentiation, Radiostereometric analysis, Total hip arthroplasty, Osseointegration

  17. Full-field measurement of micromotion around a cementless femoral stem using micro-CT imaging and radiopaque markers.

    Science.gov (United States)

    Malfroy Camine, V; Rüdiger, H A; Pioletti, D P; Terrier, A

    2016-12-08

    A good primary stability of cementless femoral stems is essential for the long-term success of total hip arthroplasty. Experimental measurement of implant micromotion with linear variable differential transformers is commonly used to assess implant primary stability in pre-clinical testing. But these measurements are often limited to a few distinct points at the interface. New techniques based on micro-computed tomography (micro-CT) have recently been introduced, such as Digital Volume Correlation (DVC) or markers-based approaches. DVC is however limited to measurement around non-metallic implants due to metal-induced imaging artifacts, and markers-based techniques are confined to a small portion of the implant. In this paper, we present a technique based on micro-CT imaging and radiopaque markers to provide the first full-field micromotion measurement at the entire bone-implant interface of a cementless femoral stem implanted in a cadaveric femur. Micromotion was measured during compression and torsion. Over 300 simultaneous measurement points were obtained. Micromotion amplitude ranged from 0 to 24µm in compression and from 0 to 49µm in torsion. Peak micromotion was distal in compression and proximal in torsion. The technique bias was 5.1µm and its repeatability standard deviation was 4µm. The method was thus highly reliable and compared well with results obtained with linear variable differential transformers (LVDTs) reported in the literature. These results indicate that this micro-CT based technique is perfectly relevant to observe local variations in primary stability around metallic implants. Possible applications include pre-clinical testing of implants and validation of patient-specific models for pre-operative planning. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Intra-articular injection of tranexamic acid via a drain plus drain-clamping to reduce blood loss in cementless total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Mutsuzaki Hirotaka

    2012-09-01

    Full Text Available Abstract Background Patients undergoing cementless total knee arthroplasty (TKA sometimes suffer large blood loss. In a retrospective study, we explored whether postoperative intra-articular retrograde injection of tranexamic acid (TA and leaving a drain clamp in place for 1 h reduced blood loss. Patients and methods Patients (n = 140 treated with unilateral primary cementless TKA (posterior cruciate ligament retained were divided into two groups: those who had an intra-articular injection of TA (1000 mg and drain clamping for 1 h postoperatively (study group, n = 70 and those who were not given TA and did not undergo clamping of their drains (control group, n = 70. Postoperative total blood loss, volume of drainage, hemoglobin level, transfusion amounts and rates, D-dimer level at postoperative day (POD 7, and complications were recorded. Results Total blood loss, total drainage, mean transfusion volume, and transfusion rates were lower in the study group than in controls (P P P  Conclusions Immediately postoperative intra-articular retrograde injection of TA and 1 h of drain-clamping effectively reduced blood loss and blood transfusion after cementless TKA. We believe that this method is simple, easy, and suitable for these patients.

  19. Study of bone remodeling of two models of femoral cementless stems by means of DEXA and finite elements

    Directory of Open Access Journals (Sweden)

    López-Prats Fernando

    2010-05-01

    Full Text Available Abstract Background A hip replacement with a cemented or cementless femoral stem produces an effect on the bone called adaptive remodelling, attributable to mechanical and biological factors. All of the cementless prostheses designs try to achieve an optimal load transfer in order to avoid stress-shielding, which produces an osteopenia. Long-term densitometric studies taken after implanting ABG-I and ABG-II stems confirm that the changes made to the design and alloy of the ABG-II stem help produce less proximal atrophy of the femur. The simulation with FE allowed us to study the biomechanical behaviour of two stems. The aim of this study was, if possible, to correlate the biological and mechanical findings. Methods Both models with prostheses ABG-I and II have been simulated in five different moments of time which coincide with the DEXA measurements: postoperative, 6 months, 1, 3 and 5 years, in addition to the healthy femur as the initial reference. For the complete comparative analysis of both stems, all of the possible combinations of bone mass (group I and group II of pacients in two controlled studies for ABG-I and II stems, respectively, prosthetic geometry (ABG-I and ABG-II and stem material (Wrought Titanium or TMZF were simulated. Results and Discussion In both groups of bone mass an increase of stress in the area of the cancellous bone is produced, which coincides with the end of the HA coating, as a consequence of the bottleneck effect which is produced in the transmission of loads, and corresponds to Gruen zones 2 and 6, where no osteopenia can be seen in contrast to zones 1 and 7. Conclusions In this study it is shown that the ABG-II stem is more effective than the ABG-I given that it generates higher tensional values on the bone, due to which proximal bone atrophy diminishes. This biomechanical behaviour with an improved transmission of loads confirmed by means of FE simulation corresponds to the biological findings obtained with

  20. Ex Vivo Evaluation of Cementless Acetabular Cup Stability Using Impact Analyses with a Hammer Instrumented with Strain Sensors.

    Science.gov (United States)

    Tijou, Antoine; Rosi, Giuseppe; Hernigou, Philippe; Flouzat-Lachaniette, Charles-Henri; Haïat, Guillaume

    2017-12-27

    The acetabular cup (AC) implant stability is determinant for the success of cementless hip arthroplasty. A method based on the analysis of the impact force applied during the press-fit insertion of the AC implant using a hammer instrumented with a force sensor was developed to assess the AC implant stability. The aim of the present study was to investigate the performance of a method using a hammer equipped with strain sensors to retrieve the AC implant stability. Different AC implants were inserted in five bovine samples with different stability conditions leading to 57 configurations. The AC implant was impacted 16 times by the two hammers consecutively. For each impact; an indicator I S (respectively I F ) determined by analyzing the time variation of the signal corresponding to the averaged strain (respectively force) obtained with the stress (respectively strain) hammer was calculated. The pull-out force F was measured for each configuration. F was significantly correlated with I S (R² = 0.79) and I F (R² = 0.80). The present method has the advantage of not modifying the shape of the hammer that can be sterilized easily. This study opens new paths towards the development of a decision support system to assess the AC implant stability.

  1. The effects of pulsed low frequency magnetic field in early rehabilitation of patients with cementless total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Đurović Aleksandar

    2006-01-01

    Full Text Available Introduction: Early rehabilitation of patients with cementless total hip arthroplasty (cTHA includes different physical modalities and pulsed low frequency magnetic field (PLFMF, which effects have not been explored yet. Objective: To investigate the effects of PLFMF which was applied in different doses in early rehabilitation of patients with cTHA. Method: Prospective, controlled, clinical study included 90 patients, divided in three groups with 30 patients each. First two groups were treated with high (group A or low (group B doses of PLFMF, in addition to kinesitherapy. Control group C was treated only with kinesitherapy. Study was completed in three weeks. Results: Subjects of group A had significantly lower pain than group B (p<0.01 and group C (p<0.001 subjects in the first postoperative week. Pain in group B subjects was significantly lower than in group C in all three postoperative weeks (p<0.01. In relation to other two groups, subjects of group A had higher hip Harris score values at the end of the third postoperative week (p<0.05, and they were faster on 10-meter distance at the end of the first postoperative week (p<0.01. Conclusion: PLFMF used in low and high doses for patients with cTHA had significant effects on pain abatement, especially at higher doses. Improvement of function was earlier and more manifested in the group treated with high doses of PLFMF.

  2. Preparation of the Femoral Bone Cavity for Cementless Stems: Broaching vs Compaction. A Five-Year Randomized Radiostereometric Analysis and Dual Energy X-Ray Absorption Study.

    Science.gov (United States)

    Hjorth, Mette H; Kold, Søren; Søballe, Kjeld; Langdahl, Bente L; Nielsen, Poul T; Christensen, Poul H; Stilling, Maiken

    2017-06-01

    Short-term experimental and animal studies have confirmed superior fixation of cementless implants inserted with compaction compared to broaching of the cancellous bone. Forty-four hips in 42 patients (19 men) were randomly operated using cementless hydroxyapatite-coated Bi-Metric stems. Patients were followed with radiostereometric analysis at baseline, 6 and 12 weeks, 1, 2, and 5 years, and measurements of periprosthetic bone mineral density at baseline, 1, 2, and 5 years. Complications during the study period and clinical outcome measures of Harris Hip Score were recorded at mean 7 years (5-8.8) after surgery. Absolute migrations of medio/lateral translations between the broaching group and the compaction group of mean 0.14 mm (standard deviation [SD] 0.10) vs mean 0.30 mm (SD 0.27) (P = .01) at 1 year, and of mean 0.13 mm (SD 0.10) vs 0.34 mm (0.31) (P = .01) at 5 years were different. Absolute valgus/varus rotations of mean 0.12° (SD 0.13°) in the broaching group were less than mean 0.35° (0.45°) in the compaction group (P .13). The compaction group had significantly less bone loss than the broaching group in Gruen zone 3 (distal-lateral to the stem) at 1 and 5 years. No further differences in bone mineral density changes were found between groups up to 5 years after surgery. Complications throughout the period and clinical outcome measures of Harris Hip Score were similar at 7 years (5-8.8) after surgery. We found increased migration when preparing the bone with compaction compared with broaching in cementless femoral stems. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Cementless One-Stage Revision in Chronic Periprosthetic Hip Joint Infection. Ninety-One Percent Infection Free Survival in 56 Patients at Minimum 2-Year Follow-Up

    DEFF Research Database (Denmark)

    Lange, Jeppe; Troelsen, Anders; Solgaard, Søren

    2018-01-01

    was re-revision performed due to infection and was evaluated by competing risk analysis, with death and aseptic revision as competing events. All-cause mortality was evaluated by Kaplan-Meier survival analysis. Oxford Hip Score (OHS) was used as disease-specific patient-reported outcome measure. RESULTS......BACKGROUND: Cementless 1-stage revision in chronic periprosthetic hip joint infections is limited evaluated. The purpose of this study was to evaluate a specific treatment protocol in this patient group. METHODS: The study was performed as a multicenter, proof-of-concept, observational study...

  4. Head Lice

    Science.gov (United States)

    ... nits. You should also use hot water to wash any bed linens, towels, and clothing recently worn by the person who had head lice. Vacuum anything that can’t be washed, such as the couch, carpets, your child’s car seat, and any stuffed animals. Because head lice ...

  5. Head Injuries

    Science.gov (United States)

    ... a severe blow to the head can still knock the brain into the side of the skull ... following certain precautions and taking a break from sports and other activities that make symptoms worse. Playing ...

  6. Effect of head contact on the rim of the cup on the offset loading and torque in hip joint replacement.

    Science.gov (United States)

    Liu, Feng; Williams, Sophie; Jin, Zhongmin; Fisher, John

    2013-11-01

    Head contact on the rim of the cup causes stress concentration and consequently increased wear. The head contact on the rim of the cup may in addition cause an offset load and torque on the cup. The head-rim contact resulting from microseparation or subluxation has been investigated. An analytical model has been developed to calculate the offset loading and resultant torque on the cup as a function of the translational displacement of the head under simplified loading condition of the hip joint at heel strike during a walking cycle. The magnitude of the torque on the cup was found to increase with the increasing translational displacement, larger diameter heads, eccentric cups, and the coefficient of friction of the contact. The effects of cup inclination, cup rim radius, and cup coverage angle on the magnitude of the torque were found to be relatively small with a maximum variation in the torque magnitude being lower than 20%. This study has shown an increased torque due to the head loading on the rim of the cup, and this may contribute to the incidence of cup loosening. Particularly, metal-on-metal hip joints with larger head diameters may produce the highest offset loading torque.

  7. Corrosion at the head-neck interface of current designs of modular femoral components: essential questions and answers relating to corrosion in modular head-neck junctions.

    Science.gov (United States)

    Osman, K; Panagiotidou, A P; Khan, M; Blunn, G; Haddad, F S

    2016-05-01

    There is increasing global awareness of adverse reactions to metal debris and elevated serum metal ion concentrations following the use of second generation metal-on-metal total hip arthroplasties. The high incidence of these complications can be largely attributed to corrosion at the head-neck interface. Severe corrosion of the taper is identified most commonly in association with larger diameter femoral heads. However, there is emerging evidence of varying levels of corrosion observed in retrieved components with smaller diameter femoral heads. This same mechanism of galvanic and mechanically-assisted crevice corrosion has been observed in metal-on-polyethylene and ceramic components, suggesting an inherent biomechanical problem with current designs of the head-neck interface. We provide a review of the fundamental questions and answers clinicians and researchers must understand regarding corrosion of the taper, and its relevance to current orthopaedic practice. Cite this article: Bone Joint J 2016;98-B:579-84. ©2016 The British Editorial Society of Bone & Joint Surgery.

  8. In Vivo Damage of the Head-Neck Junction in Hard-on-Hard Total Hip Replacements: Effect of Femoral Head Size, Metal Combination, and 12/14 Taper Design

    Directory of Open Access Journals (Sweden)

    Massimiliano Baleani

    2017-07-01

    Full Text Available Recently, concerns have been raised about the potential effect of head-neck junction damage products at the local and systemic levels. Factors that may affect this damage process have not been fully established yet. This study investigated the possible correlations among head-neck junction damage level, implant design, material combination, and patient characteristics. Head-neck junctions of 148 retrieved implants were analysed, including both ceramic-on-ceramic (N = 61 and metal-on-metal (N = 87 bearings. In all cases, the male taper was made of titanium alloy. Damage was evaluated using a four-point scoring system based on damage morphology and extension. Patient age at implantation, implantation time, damage risk factor, and serum ion concentration were considered as independent potential predicting variables. The damage risk factor summarises head-neck design characteristics and junction loading condition. Junction damage correlated with both implantation time and damage factor risk when the head was made of ceramic. A poor correlation was found when the head was made of cobalt alloy. The fretting-corrosion phenomenon seemed mainly mechanically regulated, at least when cobalt alloy components were not involved. When a component was made of cobalt alloy, the role of chemical phenomena increased, likely becoming, over implantation time, the damage driving phenomena of highly stressed junctions.

  9. Head Start.

    Science.gov (United States)

    Greenman, Geri

    2000-01-01

    Discusses an art project in which students created drawings of mop heads. Explains that the approach of drawing was more important than the subject. States that the students used the chiaroscuro technique, used by Rembrandt and Caravaggio, in which light appears out of the darkness. (CMK)

  10. [Dislocated fracture of the lesser trochanter with malrotation of the stem after robot assisted implantation of a cementless hip prosthesis: a casuistic report].

    Science.gov (United States)

    Prymka, M; Hassenpflug, J

    2003-08-01

    This paper presents the case of a 63 year old female with a severe coxarthrosis. She got a robot assited implantation of a cementless hip prosthesis (Osteolock, Stryker-Howmedica, Mühlheim). As operation robot the CASPAR-System (Orto-Maquet, Rastatt) was used. Initially, the clinical progress of the patient was fine. She was nearly painfree within 14 days and showed an acceptable range of motion in the operated joint (flexion/ extension 90 degrees /05 degrees /00 degrees ). She was mobilized with crutches and 15 kg weight bearing at the operated leg. 3 weeks postoperative the patient complaint about increasing pain without trauma or intensification of the weight bearing. X-rays showed not only a dislocated fracture of the lesser trochanter, but also a sinking combined with a malrotation of the stem. A revision operation was necessary,where we implanted a cemented stem. Now clinical progress was completely satisfying.

  11. [Stress analysis of femoral stems in cementless total hip arthroplasty by two-dimensional finite element method using boundary friction layer].

    Science.gov (United States)

    Oomori, H; Imura, S; Gesso, H

    1992-04-01

    To develop stem design achieving primary fixation of stems and effective load transfer to the femur, we studied stress analysis of stems in cementless total hip arthroplasty by two-dimensional finite element method using boundary friction layer in stem-bone interface. The results of analyses of stem-bone interface stresses and von Mises stresses at the cortical bones indicated that ideal stem design features would be as follows: 1) Sufficient length, with the distal end extending beyond the isthmus region. 2) Maximum possible width, to contact the cortical bones in the isthmus region. 3) No collars but a lateral shoulder at the proximal portion. 4) A distal tip, to contact the cortical bones at the distal portion.

  12. Risk factors for post-operative periprosthetic fractures following primary total hip arthroplasty with a proximally coated double-tapered cementless femoral component

    DEFF Research Database (Denmark)

    Gromov, K; Bersang, A; Nielsen, C S

    2017-01-01

    ratio were recorded post-operatively. Periprosthetic fractures were identified and classified according to the Vancouver classification. Regression analysis was performed to identify risk factors for early periprosthetic fracture. RESULTS: The mean follow-up was 713 days (1 to 2058). A total of 48......AIMS: The aim of this study was to identify patient- and surgery-related risk factors for sustaining an early periprosthetic fracture following primary total hip arthroplasty (THA) performed using a double-tapered cementless femoral component (Bi-Metric femoral stem; Biomet Inc., Warsaw, Indiana...... periprosthetic fractures (3.0%) were identified during the follow-up and median time until fracture was 16 days, (interquartile range 10 to 31.5). Patients with femoral Dorr type C had a 5.2 times increased risk of post-operative periprosthetic fracture compared with type B, while female patients had a near...

  13. Cementless Stem for Femoral Neck Fractures in a Patient’s 10th Decade of Life: High Rate of Periprosthetic Fractures

    Science.gov (United States)

    Kabelitz, Method; Fritz, Yannick; Grueninger, Patrick; Meier, Christoph; Fries, Patrick

    2018-01-01

    Background: Subsidence of cementless femoral stems in hemiarthroplasty (HA) and increased fracture rates are ongoing concerns of orthopedic surgeons when treating fractures in very old patients. Additionally, bone cement implantation syndrome may result in perioperative cardiac or pulmonary complications, especially in older patients, leading to morbidity and mortality. This study was performed to analyze possible subsidence and intraoperative fractures in a cohort of very old patients treated with cementless stems. Methods: We retrospectively analyzed a consecutive cohort of patients aged ≥90 years with femoral neck fractures treated by uncemented HA and an anterior minimally invasive approach. Immediate full-weight bearing was allowed postoperatively. Pelvic radiographs were examined for subsidence immediately postoperatively and 6 weeks later. Results: We treated 109 patients (74% women; mean age, 93 years; range, 90-102 years) by HA from January 2010 to March 2016. The 30-day mortality rate was 16%, and the morbidity rate was 47%. There were 11 (12%) intraoperative fractures: 8 (Vancouver B2) had to be addressed immediately during the primary operation, while 3 (1 Vancouver B1 and 2 Vancouver AG) were treated conservatively. One periprosthetic femoral fracture (Vancouver B1) was documented during follow-up. In 17 patients, subsidence of >2.0 mm (median, 3.9 mm; range, 2.5-9.0 mm) was documented. Conclusion: Early subsidence was low in this very old cohort treated with an uncemented stem and not showing a periprosthetic fracture. The risk of intraoperative periprosthetic fractures was high. The use of uncemented implants in osteoporotic bone continues to be an intervention with high risk and should only be performed by experienced surgeons. Level of Evidence: Level III, Therapeutic study. PMID:29623237

  14. Radiographic­ behavior­ of­ cementless­ sockets­ and ­its clinical correlation

    Directory of Open Access Journals (Sweden)

    German Garabano

    2013-10-01

    Full Text Available Background Radiolucent lines between cementless acetabular components and surrounding bone can be seen frequently on the immediate postoperative X-rays. The purpose of this retrospective study was to assess the clinical and radiographic behavior, if there were changes in the cup position and survival when these lines were present. Methods One hundred and twenty one Duraloc® (Depuy J&J uncemented sockets (53 model 100 and 68 model 300 were analyzed. There were 73 men and 48 women, with an average age of 58 years and a follow-up of 5.2 years. We performed a manual measurement of the X-rays to determine the presence of the radiolucent gap between the component and the acetabular bone, and the position and orientation of the cups. When this gap was observed measurements were repeated in all follow-up X-rays. Results The gap was observed in 28 (23.14% patients (9 model 100 and 19 model 300. The average gap size was 3.5 mm, being more frequent in zone II and it was filled on average 22 months after surgery in 86% of cases. The filling was partial in two cases and it did not change in four patients. The HHS for the group with the gap was 94.3 points and that for group without the gap was 93.9 points. No loosening was detected. Conclusions The presence of radiolucent line on the immediate postoperative X-rays after placement of a cementless socket has a finite duration in the majority of cases and in line with other reports it does not represent a threat to the medium and long-term survival of the component.

  15. Comparison of Outcomes of Total Hip Arthroplasty between Patients with Ankylosing Spondylitis and Avascular Necrosis of the Femoral Head.

    Science.gov (United States)

    Lee, Sun-Ho; Lee, Gun-Woo; Seol, Young-Jun; Park, Kyung-Soon; Yoon, Taek-Rim

    2017-09-01

    The objective of this study was to compare clinical and radiological outcomes of total hip arthroplasty (THA) between ankylosing spondylitis (AS) of the hip joint and avascular necrosis (AVN) of the femoral head. Thirty patients (30 hips) underwent cementless THA for AS between 2003 and 2012. They were compared to 30 patients (30 hips) who underwent the same procedure for AVN of the femoral head. Each group was matched for age and gender, and both groups had similar preoperative demographic characteristics. All cases were followed for minimum 4 postoperative years. Clinical evaluation was based on operation time, intraoperative blood loss, quantity of postoperative drainage, Harris Hip Score (HHS), and range of motion (ROM). Radiological results were evaluated by acetabular cup anteversion and inclination, femoral stem orientation, pre- and postoperative leg length discrepancy, and postoperative complications. The operation time was significantly longer in the AS group (120.2 ± 26.2 min) than in the AVN group (79.5 ± 11.1 min). The volume of postoperative drainage was significantly greater in the AS group (764.5 ± 355.4 mL vs. 510.5 ± 195.6 mL). Preoperative HHS was lower in the AS group (55.6 ± 13.8 vs. 59.2 ± 2.8). Similarly, postoperative HHS was significantly lower in the AS group (92.8 ± 2.7 vs. 97.4 ± 2.6). The arc of ROM was improved from 146.5° ± 13.2° preoperatively to 254.7° ± 17.2° postoperatively in the AS group and from 182.6° ± 15.5° to 260.4° ± 13.7° in the AVN group. Implant position and postoperative leg length discrepancy were not different between the groups. However, three cases of heterotopic ossification was observed in the AS group, whereas only 1 case was found in the AVN group. One deep infection and one aseptic stem loosening were found in the AS group, whereas none was observed in the AVN group. Cementless THA showed satisfactory clinical and radiological results in both groups, despite the longer operation time

  16. Flued head replacement alternatives

    International Nuclear Information System (INIS)

    Smetters, J.L.

    1987-01-01

    This paper discusses flued head replacement options. Section 2 discusses complete flued head replacement with a design that eliminates the inaccessible welds. Section 3 discusses alternate flued head support designs that can drastically reduce flued head installation costs. Section 4 describes partial flued head replacement designs. Finally, Section 5 discusses flued head analysis methods. (orig./GL)

  17. Goniometer head

    International Nuclear Information System (INIS)

    Dzhazairov-Kakhramanov, V.; Berger, V.D.; Kadyrzhanov, K.K.; Zarifov, R.A.

    1994-01-01

    The goniometer head is an electromechanical instrument that performs the independent transfer of a testing sample on three coordinate axes (X, Y, Z) within limits of ±8 mm and independent rotation relative of these directions. The instrument comprises a sample holder, bellows component and three electrometer drives. The sample holder rotates around the axes X and Y, and is installed on the central arm which rotates around axis Z. One characteristic of this instrument is its independence which allows its use in any camera for researches in the field of radiation physics. 2 figs

  18. Is HEADS in our heads?

    DEFF Research Database (Denmark)

    Boisen, Kirsten A; Hertz, Pernille Grarup; Blix, Charlotte

    2016-01-01

    contraception], Safety, Self-harm) interview is a feasible way of exploring health risk behaviors and resilience. OBJECTIVE: The purpose of this study was to evaluate how often HEADS topics were addressed according to young patients and staff in pediatric and adult outpatient clinics. METHODS: We conducted...... care professionals participated. We found only small reported differences between staff and young patients regarding whether home, education, and activity were addressed. However, staff reported twice the rate of addressing smoking, alcohol, illegal drugs, sexuality, and contraception compared to young...... patients. Young patients reported that smoking, alcohol, illegal drugs, sexuality, and contraception were addressed significantly more at adult clinics in comparison to pediatric clinics. After controlling for age, gender and duration of illness, according to young patients, adjusted odds ratios...

  19. Head Impact Laboratory (HIL)

    Data.gov (United States)

    Federal Laboratory Consortium — The HIL uses testing devices to evaluate vehicle interior energy attenuating (EA) technologies for mitigating head injuries resulting from head impacts during mine/...

  20. Heading and head injuries in soccer.

    Science.gov (United States)

    Kirkendall, D T; Jordan, S E; Garrett, W E

    2001-01-01

    In the world of sports, soccer is unique because of the purposeful use of the unprotected head for controlling and advancing the ball. This skill obviously places the player at risk of head injury and the game does carry some risk. Head injury can be a result of contact of the head with another head (or other body parts), ground, goal post, other unknown objects or even the ball. Such impacts can lead to contusions, fractures, eye injuries, concussions or even, in rare cases, death. Coaches, players, parents and physicians are rightly concerned about the risk of head injury in soccer. Current research shows that selected soccer players have some degree of cognitive dysfunction. It is important to determine the reasons behind such deficits. Purposeful heading has been blamed, but a closer look at the studies that focus on heading has revealed methodological concerns that question the validity of blaming purposeful heading of the ball. The player's history and age (did they play when the ball was leather and could absorb significant amounts of water), alcohol intake, drug intake, learning disabilities, concussion definition and control group use/composition are all factors that cloud the ability to blame purposeful heading. What does seem clear is that a player's history of concussive episodes is a more likely explanation for cognitive deficits. While it is likely that the subconcussive impact of purposeful heading is a doubtful factor in the noted deficits, it is unknown whether multiple subconcussive impacts might have some lingering effects. In addition, it is unknown whether the noted deficits have any affect on daily life. Proper instruction in the technique is critical because if the ball contacts an unprepared head (as in accidental head-ball contacts), the potential for serious injury is possible. To further our understanding of the relationship of heading, head injury and cognitive deficits, we need to: learn more about the actual impact of a ball on the

  1. Head Trauma: First Aid

    Science.gov (United States)

    First aid Head trauma: First aid Head trauma: First aid By Mayo Clinic Staff Most head trauma involves injuries that are minor and don't require ... 21, 2015 Original article: http://www.mayoclinic.org/first-aid/first-aid-head-trauma/basics/ART-20056626 . Mayo ...

  2. Head and neck cancer

    International Nuclear Information System (INIS)

    Vogl, S.E.

    1988-01-01

    This book contains 10 chapters. Some of the titles are: Combined Surgical Resection and Irradiation for Head and Neck Cancers; Analysis of Radiation Therapy Oncology Group Head and Neck Database: Identification of Prognostic Factors and the Re-evaluation of American Joint Committee Stages; Combined Modality Approach to Head and Neck Cancer; Induction Combination Chemotherapy of Regionally Advanced Head and Neck Cancer; and Outcome after Complete Remission to Induction Chemotherapy in Head and Neck Cancer

  3. Hydroxyapatite in total hip arthroplasty. Our experience with a plasma spray porous titanium alloy/hydroxyapatite double-coated cementless stem.

    Science.gov (United States)

    Castellini, Iacopo; Andreani, Lorenzo; Parchi, Paolo Domenico; Bonicoli, Enrico; Piolanti, Nicola; Risoli, Francesca; Lisanti, Michele

    2016-01-01

    Total hip arthroplasty could fail due to many factors and one of the most common is the aseptic loosening. In order to achieve an effective osseointegration and reduce risk of lossening, the use of cemented implant, contact porous bearing surface and organic coating were developed. Aim of this study was to evaluate clinical and radiological mid-term outcomes of a porous titanium alloy/hydroxyapatite double coating manufactured cementless femoral stem applied with "plasma spray" technique and to demonstrate the possibility to use this stem in different types of femoral canals. Between January 2008 and December 2012, 240 consecutive primary total hip arthroplasties (THAs) were performed using a porous titanium alloy/hydroxyapatite double coating manufactured cementless femoral stem. 182 patients were examined: 136 were females (74.7%) and 46 males (25.2%); average age was 72 years old (ranging from 26 to 92 years old). For each patient, Harris Hip Scores (HHS) and Womac Scores were collected. All X-ray images were analyzed in order to demonstrate stem survival rate and subsidence. Harris Hip Score was good or excellent in 85% of the cases (average 90%) and mean WOMAC score was 97.5 (ranging from 73.4 to 100). No cases of early/late infection or periprosthetic fracture were noticed, with an excellent implant survival rate (100%) in a mean period of 40 months (ranging from 24 and 84 months). 5 cases presented acute implant dislocation, 2 due to wrong cup positioning in a dysplastic acetabulum and 3 after ground level fall. Dorr classification of femoral geometry was uses and the results were: 51 type A bone, 53 type B bone and 78 type C bone. Stem subsidence over 2 mm was considered as a risk factor of future implant loosening and was evidenced in 3 female patients with type C of Dorr classification. No radiolucencies signs around the proximally coated portion of stem or proximal reabsorption were visible during the radiographic follow-up. Concerning the use of porous

  4. Cementless anatomical prosthesis for the treatment of 3-part and 4-part proximal humerus fractures: cadaver study and prospective clinical study with minimum 2 years followup

    Directory of Open Access Journals (Sweden)

    Obert Laurent

    2016-01-01

    Full Text Available Introduction: The purpose of this study was to evaluate the functional and radiological outcomes of a cementless, trauma-specific locked stem for 3- and 4-part proximal humeral fractures. Materials and methods: This study consisted of two parts: a cadaver study with 22 shoulders and a multicenter prospective clinical study of 23 fracture patients evaluated at least 2 years after treatment. In the cadaver study, the locked stem (HumelockTM, FX Solutions and its instrumentation were evaluated. In the clinical study, five senior surgeons at four different hospitals performed the surgical procedures. An independent surgeon evaluated the patients using clinical (Constant score, QuickDASH and radiological (X-rays, CT scans outcome measures. Results: The cadaver study allowed us to validate the height landmarks relative to the pectoralis major tendon. In the clinical study, at the review, abduction was 95° (60–160, forward flexion was 108° (70–160, external rotation (elbow at body was 34° (0–55, the QuickDASH was 31 (4.5–59, the overall Constant score was 54 (27–75, and the weighted Constant score was 76 (31.5–109. Discussion: This preliminary study of hemiarthroplasty (HA with a locked stem found results that were at least equivalent to published series. As all patients had at least a 2-year follow-up, integration of the locked stem did not cause any specific complications. These results suggest that it is possible to avoid using cement when hemiarthroplasty is performed for the humeral stem. This implant makes height adjustment and transosseous suturing of the tuberosities more reproducible.

  5. Head injury - first aid

    Science.gov (United States)

    ... medlineplus.gov/ency/article/000028.htm Head injury - first aid To use the sharing features on this page, ... a concussion can range from mild to severe. First Aid Learning to recognize a serious head injury and ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the head uses special x-ray equipment to help assess head injuries, severe headaches, dizziness, and other ... aneurysm, bleeding, stroke and brain tumors. It also helps your doctor to evaluate your face, sinuses, and ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  11. The unipolar ASR : Viable option in unsalvageable femoral head conditions in the young patient

    Directory of Open Access Journals (Sweden)

    Marya SKS

    2006-01-01

    Full Text Available Background: The management of unsalvageable femoral head conditions in the young patient has remained an unresolved dilemma. Articular surface replacement of the hip has recently made some headway in terms of providing near-normal hip joint mechanics and function. However, this surgery has been limited to early stages of arthritis only with reasonable maintenance of head-neck congruity and morphology. Femoral neck fractures, osteonecrosis with large segment collapse, advanced arthritis with femoral incongruity, etc are traditional contraindications to the resurfacing technique. Methods: We present here a report on our series of 20 cases of unsalvageable femoral heads in young patients (age range, 27 to 52yrs, over a twelve month period (Aug 2004 to Jul 2005, treated with the unipolar ASR prosthesis. Fifteen patients (two had bilateral hip pathology had primary or secondary arthritis (degenerative, post-traumatic, ankylosing spondylitis and post-avascular necrosis while three had old operated femoral neck fractures. All patients underwent hip replacement surgery using the Unipolar ASR prosthesis. Results: Clinical and radiological results at 6-month follow up have been very encouraging and warrant further study. At an average of 4 months post-operatively, patients were able to squat, sit on the ground and perform light sporting activities. Conclusions: The Unipolar ASR prosthesis is an extension of the articular resurfacing technique employing similar principles (large size bearings, metal-on-metal interfaces, and has incorporated the advantages of the uncemented technique. We propose that this technique be more frequently used so as to brighten the prognosis of the young active patient with unsalvageable hip conditions, especially in the Asian scenario.

  12. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ... Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ...

  13. Head CT scan

    Science.gov (United States)

    ... scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... head size in children Changes in thinking or behavior Fainting Headache, when you have certain other signs ...

  14. Bottom head assembly

    International Nuclear Information System (INIS)

    Fife, A.B.

    1998-01-01

    A bottom head dome assembly is described which includes, in one embodiment, a bottom head dome and a liner configured to be positioned proximate the bottom head dome. The bottom head dome has a plurality of openings extending there through. The liner also has a plurality of openings extending there through, and each liner opening aligns with a respective bottom head dome opening. A seal is formed, such as by welding, between the liner and the bottom head dome to resist entry of water between the liner and the bottom head dome at the edge of the liner. In the one embodiment, a plurality of stub tubes are secured to the liner. Each stub tube has a bore extending there through, and each stub tube bore is coaxially aligned with a respective liner opening. A seat portion is formed by each liner opening for receiving a portion of the respective stub tube. The assembly also includes a plurality of support shims positioned between the bottom head dome and the liner for supporting the liner. In one embodiment, each support shim includes a support stub having a bore there through, and each support stub bore aligns with a respective bottom head dome opening. 2 figs

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  17. Impaction grafting in the femur in cementless modular revision total hip arthroplasty: a descriptive outcome analysis of 243 cases with the MRP-TITAN revision implant

    Directory of Open Access Journals (Sweden)

    Wimmer Matthias D

    2013-01-01

    .1% after 8.7 years]. Radiologic evaluation showed no significant change in axial implant migration (4.3% vs. 9.3%; p = 0.19 but a significant reduction in proximal stress shielding (5.7% vs. 17.9%; p  Conclusion We present the largest analysis of the impaction grafting technique in combination with cementless distal diaphyseal stem fixation published so far. Our data provides initial evidence of improved bone regeneration after graft augmentation of metaphyseal bone defects. The data suggests that proximal metaphyseal graft augmentation is beneficial for large metaphyseal bone defects (Paprosky types IIC and III and stem diameters of 17 mm and above. Due to the limitations of a retrospective and descriptive study the level of evidence remains low and prospective trials should be conducted.

  18. Reactor head shielding apparatus

    International Nuclear Information System (INIS)

    Schukei, G.E.; Roebelen, G.J.

    1992-01-01

    This patent describes a nuclear reactor head shielding apparatus for mounting on spaced reactor head lifting members radially inwardly of the head bolts. It comprises a frame of sections for mounting on the lifting members and extending around the top central area of the head, mounting means for so mounting the frame sections, including downwardly projecting members on the frame sections and complementary upwardly open recessed members for fastening to the lifting members for receiving the downwardly projecting members when the frame sections are lowered thereto with lead shielding supported thereby on means for hanging lead shielding on the frame to minimize radiation exposure or personnel working with the head bolts or in the vicinity thereof

  19. Femoral head avascular necrosis

    International Nuclear Information System (INIS)

    Chrysikopoulos, H.; Sartoris, D.J.; Resnick, D.L.; Ashburn, W.; Pretorius, T.

    1988-01-01

    MR imaging has been shown to be more sensitive and specific than planar scintigraphy for avascular necrosis (AVN) of the femoral head. However, experience with single photon emission CT (SPECT) is limited. The authors retrospectively compared 1.5-T MR imaging with SPECT in 14 patients with suspected femoral head AVN. Agreement between MR imaging and SPECT was present in 24 femurs, 14 normal and ten with AVN. MR imaging showed changes of AVN in the remaining four femoral heads. Of these, one was normal and the other three inconclusive for AVN by SPECT. The authors conclude that MR imaging is superior to SPECT for the evaluation of AVN of the hip

  20. Protective head of sensors

    International Nuclear Information System (INIS)

    Liska, K.; Anton, P.

    1987-01-01

    The discovery concerns the protective heads of diagnostic assemblies of nuclear power plants for conductors of the sensors from the fuel and control parts of the said assemblies. A detailed description is presented of the design of the protective head which, as compared with the previous design, allows quick and simple assembly with reduced risk of damaging the sensors. The protective head may be used for diagnostic assemblies both in power and in research reactors and it will be used for WWER reactor assemblies. (A.K.). 3 figs

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to ...

  2. Exploding head syndrome.

    Science.gov (United States)

    Sharpless, Brian A

    2014-12-01

    Exploding head syndrome is characterized by the perception of abrupt, loud noises when going to sleep or waking up. They are usually painless, but associated with fear and distress. In spite of the fact that its characteristic symptomatology was first described approximately 150 y ago, exploding head syndrome has received relatively little empirical and clinical attention. Therefore, a comprehensive review of the scientific literature using Medline, PsycINFO, Google Scholar, and PubMed was undertaken. After first discussing the history, prevalence, and associated features, the available polysomnography data and five main etiological theories for exploding head syndrome are summarized. None of these theories has yet reached dominance in the field. Next, the various methods used to assess and treat exploding head syndrome are discussed, as well as the limited outcome data. Finally, recommendations for future measure construction, treatment options, and differential diagnosis are provided. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... medically necessary because of potential risk to the baby. This risk is, however, minimal with head CT ... intravenous contrast indicate mothers should not breastfeed their babies for 24-48 hours after contrast medium is ...

  4. Early Head Start Evaluation

    Data.gov (United States)

    U.S. Department of Health & Human Services — Longitudinal information from an evaluation where children were randomly assigned to Early Head Start or community services as usual;direct assessments and...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain Tumors Radiation Therapy for ... Tomography (CT) - Head Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much ... head CT scanning. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... rays). top of page What are some common uses of the procedure? CT scanning of the head ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... rays). top of page What are some common uses of the procedure? CT scanning of the head ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  10. Head Start Impact Study

    Data.gov (United States)

    U.S. Department of Health & Human Services — Nationally representative, longitudinal information from an evaluation where children were randomly assigned to Head Start or community services as usual;direct...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  12. TCGA head Neck

    Science.gov (United States)

    Investigators with The Cancer Genome Atlas (TCGA) Research Network have discovered genomic differences – with potentially important clinical implications – in head and neck cancers caused by infection with the human papillomavirus (HPV).

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... your doctor to evaluate your face, sinuses, and skull or to plan radiation therapy for brain cancer. ... typically used to detect: bleeding, brain injury and skull fractures in patients with head injuries. bleeding caused ...

  14. The exploding head syndrome.

    Science.gov (United States)

    Green, M W

    2001-06-01

    This article reviews the features of an uncommon malady termed "the exploding head syndrome." Sufferers describe terrorizing attacks of a painless explosion within their head. Attacks tend to occur at the onset of sleep. The etiology of attacks is unknown, although they are considered to be benign. Treatment with clomipramine has been suggested, although most sufferers require only reassurance that the spells are benign in nature.

  15. GPK heading machine

    Energy Technology Data Exchange (ETDEWEB)

    Krmasek, J.; Novosad, K.

    1981-01-01

    This article evaluates performance tests of the Soviet made GPK heading machine carried out in 4 coal mines in Czechoslovakia (Ostrava-Karvina region and Kladno mines). GPK works in coal seams and rocks with compression strength of 40 to 50 MPa. Dimensions of the tunnel are height 1.8 to 3.8 m and width 2.6 to 4.7 m, tunnel gradient plus to minus 10 degrees. GPK weighs 16 t, its conical shaped cutting head equipped with RKS-1 cutting tools is driven by an electric motor with 55 kW capacity. Undercarriage of the GPK, gathering-arm loader, hydraulic system, electric system and dust supression system (water spraying or pneumatic section) are characterized. Specifications of GPK heading machines are compared with PK-3r and F8 heading machines. Reliability, number of failures, dust level, noise, productivity depending on compression strength of rocks, heading rate in coal and in rocks, energy consumption, performance in inclined tunnels, and cutting tool wear are evaluated. Tests show that GPK can be used to drive tunnels in coal with rock constituting up to 50% of the tunnel crosscut, as long as rock compression strength does not exceed 50 MPa. In rocks characterized by higher compression strength cutting tool wear sharply increases. GPK is characterized by higher productivity than that of the PK-3r heading machine. Among the weak points of the GPK are: unsatisfactory reliability and excessive wear of its elements. (4 refs.) (In Czech)

  16. Magnetic Resonance Imaging (MRI) -- Head

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  18. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... find out more. Oral, Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ... find out more. Oral, Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ...

  19. Head, Neck, and Oral Cancer

    Science.gov (United States)

    ... find out more. Oral, Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ... find out more. Oral, Head and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed ...

  20. [S3 Guideline. Part 3: Non-Traumatic Avascular Necrosis in Adults - Surgical Treatment of Atraumatic Avascular Femoral Head Necrosis in Adults].

    Science.gov (United States)

    Maus, U; Roth, A; Tingart, M; Rader, C; Jäger, M; Nöth, U; Reppenhagen, S; Heiss, C; Beckmann, J

    2015-10-01

    The present article describes the guidelines for the surgical treatment of atraumatic avascular necrosis (aFKN). These include joint preserving and joint replacement procedures. As part of the targeted literature, 43 publications were included and evaluated to assess the surgical treatment. According to the GRADE and SIGN criteria level of evidence (LoE), grade of recommendation (EC) and expert consensus (EK) were listed for each statement and question. The analysed studies have shown that up to ARCO stage III, joint-preserving surgery can be performed. A particular joint-preserving surgery currently cannot be recommended as preferred method. The selection of the method depends on the extent of necrosis. Core decompression performed in stage ARCO I (reversible early stage) or stage ARCO II (irreversible early stage) with medial or central necrosis with an area of less than 30 % of the femoral head shows better results than conservative therapy. In ARCO stage III with infraction of the femoral head, the core decompression can be used for a short-term pain relief. For ARCO stage IIIC or stage IV core decompression should not be performed. In these cases, the indication for implantation of a total hip replacement should be checked. Additional therapeutic procedures (e.g., osteotomies) and innovative treatment options (advanced core decompression, autologous bone marrow, bone grafting, etc.) can be discussed in the individual case. In elective hip replacement complications and revision rates have been clearly declining for decades. In the case of an underlying aFKN, however, previous joint-preserving surgery (osteotomies and grafts in particular) can complicate the implantation of a THA significantly. However, the implant life seems to be dependent on the aetiology. Higher revision rates for avascular necrosis are particularly expected in sickle cell disease, Gaucher disease, or kidney transplantation patients. Furthermore, the relatively young age of the patient

  1. Resultados de revisão de artroplastia total do joelho com haste não cimentada "Press-fit" Results of revision total knee arthroplasty using press-fit cementless stem

    Directory of Open Access Journals (Sweden)

    Maurício Masasi Iamaguchi

    2013-02-01

    Full Text Available OBJETIVO: Mostrar nossa experiência com haste não-cimentadas press-fit e fixação metafisária com cimento em série selecionada de pacientes que realizaram revisão de artroplastia total do joelho. MÉTODOS: Trinta e quatro pacientes (35 joelhos foram submetidos a revisão de artroplastia total do joelho usando técnica "press-fit". Seguimento mínimo foi de um ano (média de 2,2 anos e máximo de três anos. RESULTADOS: Dos 34 pacientes, 20 foram mulheres e 14 foram homens. Houve um óbito por causa não relacionada a artroplastia e perda de seguimento de um paciente. Não houve nenhum caso em que fosse necessária nova revisão. Os pacientes que foram submetidos à revisão apresentaram melhora clínica e funcional demonstrado pelos resultados do KSS, resultados do questionário de qualidade de vida SF-36, através do ganho de amplitude de movimento e da melhora no alinhamento do membro. CONCLUSÃO: Houve melhora clínica e funcional no pós-operatório em relação ao pré-operatório na revisão de artroplastia total do Joelho com haste não cimentada "press-fit". Nível de Evidência IV, Série de casos.OBJECTIVE: To show our experience with press-fit cementless stem and metaphyseal fixation with cement in a selected series of patients who underwent revision total knee arthroplasty. METHODS: Thirty-four patients (35 knees underwent revision total knee arthroplasty using the press-fit technique. Minimum follow-up was one year (mean 2.2 years with a maximum length of three years. RESULTS: Of 34 patients, 20 were women and 14 were men. There was one death due to causes not related to arthroplasty and one patient dropout. There were no cases in which further review was necessary. Patients who underwent revision had clinical and functional improvement demonstrated by the results of the KSS, results of the SF-36 quality of life questionnaire, through gains in range of motion and improved limb alignment. CONCLUSION: There was postoperative

  2. Head first Ajax

    CERN Document Server

    Riordan, Rebecca M

    2008-01-01

    Ajax is no longer an experimental approach to website development, but the key to building browser-based applications that form the cornerstone of Web 2.0. Head First Ajax gives you an up-to-date perspective that lets you see exactly what you can do -- and has been done -- with Ajax. With it, you get a highly practical, in-depth, and mature view of what is now a mature development approach. Using the unique and highly effective visual format that has turned Head First titles into runaway bestsellers, this book offers a big picture overview to introduce Ajax, and then explores the use of ind

  3. Head First Statistics

    CERN Document Server

    Griffiths, Dawn

    2009-01-01

    Wouldn't it be great if there were a statistics book that made histograms, probability distributions, and chi square analysis more enjoyable than going to the dentist? Head First Statistics brings this typically dry subject to life, teaching you everything you want and need to know about statistics through engaging, interactive, and thought-provoking material, full of puzzles, stories, quizzes, visual aids, and real-world examples. Whether you're a student, a professional, or just curious about statistical analysis, Head First's brain-friendly formula helps you get a firm grasp of statistics

  4. Influence of cup-center-edge angle on micro-motion at the interface between the cup and host bone in cementless total hip arthroplasty: three-dimensional finite element analysis.

    Science.gov (United States)

    Kaku, Nobuhiro; Tabata, Tomonori; Tsumura, Hiroshi

    2015-12-01

    We verified the index cup position required for bulk bone grafting instead of morcellized grafting immediately after cementless total hip arthroplasty. Three-dimensional finite element analysis was used to evaluate changes in the volume of the slippage of the cup-host bone interface as micro-motion of the cup at the acetabular bone defect site depending on the cup-center-edge (CE) angle. The conditions of bulk bone grafts were similar to those of cortical bone. Slippage increased with decreasing cup-CE angle. A bulk bone graft tightly fixed to the host bone prevented considerably larger slippage between the cup and host bone. A smaller cup-CE angle increased the impact of the bulk bone graft on slippage. When the cup-CE angle was 0° or -10°, the criterion for slippage in favorable initial fixation in all conditions was cup and bone graft, it is impossible to obtain reliable fixation of the cup with a cup-CE angle cup-host bone fixation, especially when the cup-CE angle is small, such as cups, and sufficient fixation between the host bone and cup or bulk bone graft using a screw is effective when the cup-CE angle is extremely small.

  5. Silva as the Head

    DEFF Research Database (Denmark)

    Svabo, Connie

    2015-01-01

    The head of the performance design programme is substituted by a sister's academy delegate. this performance situation formed part of a week of semesterstart where the students and professors visited Sister's Academy, Malmø. I participated in the Sister's Academy as visiting researcher and here i...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... are present in the paranasal sinuses. plan radiation therapy for cancer of the brain or other tissues. guide the ... RTAnswers.org Radiation Therapy for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association top ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Blood Clots CT Perfusion of the Head CT Angiography ( ...

  9. The Twente humanoid head

    NARCIS (Netherlands)

    Reilink, Rob; Visser, L.C.; Bennik, J.; Carloni, Raffaella; Brouwer, Dannis Michel; Stramigioli, Stefano

    2009-01-01

    This video shows the results of the project on the mechatronic development of the Twente humanoid head. The mechanical structure consists of a neck with four degrees of freedom (DOFs) and two eyes (a stereo pair system) which tilt on a common axis and rotate sideways freely providing a three more

  10. Head injury in children

    International Nuclear Information System (INIS)

    Sugiura, Makoto; Mori, Nobuhiko; Yokosuka, Reiko; Yamamoto, Masaaki; Imanaga, Hirohisa

    1981-01-01

    Findings of computerized tomography (CT) in 183 cases of head injury in children were investigated with special reference to CT findings of mild head injury. As was expected, CT findings of mild head injury fell within the normal range, in almost all cases. However, abnormal findings were noticed in 4 out of 34 cases (12%) in acute stage and 7 out of 76 cases (9%) in chronic stage. They were 3 cases of localized low density area in acute stage and 6 cases of mild cerebral atrophy in chronic stage, etc. There were some cases of mild head injury in which CT findings were normal while EEG examination revealed abnormality. Also in some cases, x-ray study demonstrated linear skull fracture which CT failed to show. These conventional techniques could be still remained as useful adjunct aid in diagnosis of head injury. CT findings of cases of cerebral contusion in their acute stage were divided as follows; normal, low density, small ventricle and ventricular and/or cisternal hemorrhage, frequency of incidence being 38, 17, 22, 11% respectively. These findings were invariably converted to cerebral atrophy from 10 days to 2 months after the impacts. In the cases with intracranial hematoma revealed by CT, only 32% of them showed clinical signs of Araki's type IV in their acute stage and 63% of them showed no neurological defects, that is Araki's type I and II. A case of extreme diffuse cerebral atrophy which followed acute subdural hematoma caused by tear of bridging veins without cortical contusion was presented. (author)

  11. Head and Neck Cancer Treatment

    Science.gov (United States)

    ... Professions Site Index A-Z Head and Neck Cancer Treatment Head and neck cancer overview What are my ... and neck cancer. For updated information on new cancer treatments that are available, you should discuss these issues ...

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others : American Stroke Association National Stroke Association ... MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging ( ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... are the limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging ( ... brain) in routine clinical practice. top of page What are some common uses of the procedure? MR ...

  14. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed with ... and Neck Pathology Oral, Head and Neck Pathology Close to 49,750 Americans will be diagnosed with ...

  15. Head Lice: Prevention and Control

    Science.gov (United States)

    ... and General Public. Contact Us Parasites Home Prevention & Control Language: English (US) Español (Spanish) Recommend on Facebook ... that can be taken to help prevent and control the spread of head lice: Avoid head-to- ...

  16. MRI in head trauma

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jin Kyo [Shin Wha Hospital, Seoul (Korea, Republic of)

    1986-02-15

    In the diagnosis of head injury, Magnetic Resonance Imaging (MRI), like CT, is an effective method of distinguishing between intracerebral and extracerebral lesions. In our experience of MRI, early hematomas are almost isointense by Saturation Recovery (SR) method, so these must be performed with Spin Echo (SE) method for better visualization of hematomas. Isodense subdural hematomas, which is a diagnostic dilemma on CT images, are clearly seen on MRI. Delayed hematomas or residual parenchymal lesions are better demonstrated on MRI than on CT. Direct cornal, sagittal images and multiplanar facility of MRI provides excellent visualization of the the location and shape of extracerebral collection of hematoma. For the screening of head traumas, SE method is a technique of choice because of its excellent sensitivity within limited time.

  17. Where is Russia heading?

    Directory of Open Access Journals (Sweden)

    Natalija Pliskevič

    1999-10-01

    Full Text Available The author examines the proceedings from the collection Where is Russia Heading? (= Куда идёт Россия?, published between 1994 and 1998 in connection with the international symposium held under this name each year in Moscow. The symposia and their proceeding, involving leading Russian and foreign experts, were significant in that they encompassed a wide range of themes – social, economic, political, legislative, cultural and other transformations that have been occurring in Russia during the past decades. The author, however, limits her review to contributions dealing with ethno-political and socio-cultural transformations in Russia. She concludes that the question – “Where is Russia heading?” – still remains open to answers.

  18. MRI in head trauma

    International Nuclear Information System (INIS)

    Hong, Jin Kyo

    1986-01-01

    In the diagnosis of head injury, Magnetic Resonance Imaging (MRI), like CT, is an effective method of distinguishing between intracerebral and extracerebral lesions. In our experience of MRI, early hematomas are almost isointense by Saturation Recovery (SR) method, so these must be performed with Spin Echo (SE) method for better visualization of hematomas. Isodense subdural hematomas, which is a diagnostic dilemma on CT images, are clearly seen on MRI. Delayed hematomas or residual parenchymal lesions are better demonstrated on MRI than on CT. Direct cornal, sagittal images and multiplanar facility of MRI provides excellent visualization of the the location and shape of extracerebral collection of hematoma. For the screening of head traumas, SE method is a technique of choice because of its excellent sensitivity within limited time.

  19. "Head versus heart"

    Directory of Open Access Journals (Sweden)

    Paul Rozin

    2007-08-01

    Full Text Available Most American respondents give ``irrational,'' magical responses in a variety of situations that exemplify the sympathetic magical laws of similarity and contagion. In most of these cases, respondents are aware that their responses (usually rejections, as of fudge crafted to look like dog feces, or a food touched by a sterilized, dead cockroach are not ``scientifically'' justified, but they are willing to avow them. We interpret this, in some sense, as ``heart over head.'' We report in this study that American adults and undergraduates are substantially less likely to acknowledge magical effects when the judgments involve money (amount willing to pay to avoid an ``unpleasant'' magical contact than they are when using preference or rating measures. We conclude that in ``head-heart'' conflicts of this type, money tips the balance towards the former, or, in other words, that money makes the mind less magical.

  20. [The exploding head syndrome].

    Science.gov (United States)

    Bongers, K M; ter Bruggen, J P; Franke, C L

    1991-04-06

    The case is reported of a 47-year old female suffering from the exploding head syndrome. This syndrome consists of a sudden awakening due to a loud noise shortly after falling asleep, sometimes accompanied by a flash of light. The patient is anxious and experiences palpitations and excessive sweating. Most patients are more than fifty years of age. Further investigations do not reveal any abnormality. The pathogenesis is unknown, and no therapy other than reassurance is necessary.

  1. Where are we heading

    International Nuclear Information System (INIS)

    Noto, L.A.

    1996-01-01

    The present paper deals with different aspects connected to the global petroleum industry by discussing the way of heading. The aspects cover themes like new frontiers, new relationships, sanctions, global climate change, new alliances and new technology. New frontiers and relationships concern domestic policy affecting the industry, and sanctions are discussed in connection with trade. The author discusses the industry's participation in the global environmental policy and new alliances to provide greater opportunity for developing new technology

  2. "Head versus heart"

    OpenAIRE

    Paul Rozin; Heidi Grant; Stephanie Weinberg; Scott Parker

    2007-01-01

    Most American respondents give ``irrational,'' magical responses in a variety of situations that exemplify the sympathetic magical laws of similarity and contagion. In most of these cases, respondents are aware that their responses (usually rejections, as of fudge crafted to look like dog feces, or a food touched by a sterilized, dead cockroach) are not ``scientifically'' justified, but they are willing to avow them. We interpret this, in some sense, as ``heart over head.'' We report in this ...

  3. Head segmentation in vertebrates

    OpenAIRE

    Kuratani, Shigeru; Schilling, Thomas

    2008-01-01

    Classic theories of vertebrate head segmentation clearly exemplify the idealistic nature of comparative embryology prior to the 20th century. Comparative embryology aimed at recognizing the basic, primary structure that is shared by all vertebrates, either as an archetype or an ancestral developmental pattern. Modern evolutionary developmental (Evo-Devo) studies are also based on comparison, and therefore have a tendency to reduce complex embryonic anatomy into overly simplified patterns. Her...

  4. On the matter of synovial fluid lubrication: implications for Metal-on-Metal hip tribology.

    Science.gov (United States)

    Myant, Connor; Cann, Philippa

    2014-06-01

    Artificial articular joints present an interesting, and difficult, tribological problem. These bearing contacts undergo complex transient loading and multi axes kinematic cycles, over extremely long periods of time (>10 years). Despite extensive research, wear of the bearing surfaces, particularly metal-metal hips, remains a major problem. Comparatively little is known about the prevailing lubrication mechanism in artificial joints which is a serious gap in our knowledge as this determines film formation and hence wear. In this paper we review the accepted lubrication models for artificial hips and present a new concept to explain film formation with synovial fluid. This model, recently proposed by the authors, suggests that interfacial film formation is determined by rheological changes local to the contact and is driven by aggregation of synovial fluid proteins. The implications of this new mechanism for the tribological performance of new implant designs and the effect of patient synovial fluid properties are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Adsorption of metals on metal surfaces and the possibilities of its application in nuclear chemistry

    International Nuclear Information System (INIS)

    Roesch, F.; Eichler, B.

    1986-01-01

    Starting with values of differential enthalpies of adsorption ΔH-bar/sub a/ the desorption temperatures of 65 adsorptive metals as to 40 adsorbens metals have been obtained according to a model calculation. With regard to their potential separation by means of selective desorption from solid metal surfaces the desorption behaviour of combinations of radionuclides Me 1 (proton number Z)/Me 2 (proton number Z+1) and Me 1 (proton number Z)/Me 2 (proton number Z+2) was calculated. Basing on the parameters of the model assumptions, the results of the calculations allow estimations about the desorption temperatures of the adsorptive Me 1 as well as the temperature differences to the desorption of the adsorptive Me 2 and about the efficiency of the potential separation process. (author)

  6. Metallosis: A diagnosis not only in patients with metal-on-metal prostheses

    International Nuclear Information System (INIS)

    Oliveira, Catarina A.; Candelária, Isabel S.; Oliveira, Pedro B.; Figueiredo, Antonio; Caseiro-Alves, Filipe

    2014-01-01

    Although the real actual incidence of metallosis is unknown, it is described as a rare diagnosis with a 5% estimated incidence in the hip prosthetic replacements. The adoption of non-metallic articular prosthetic devices, made of polyethylene and ceramic, is the main reason to the diminishing number of reported cases. We present a case of metallosis with a clinical systemic presentation in a patient with a non-metallic hip prosthesis, which occurred due to a fracture of the acetabular liner component, leading to abnormal metal–metal contact. The metallic debris leads to a massive local and systemic release of cytokines. Revision is necessary whenever osteolysis and loosening of the prosthesis occur. Imaging evaluation, especially CT, has a central role in diagnosis and planning the surgical treatment

  7. Adsorption of volatile metals on metal surfaces and the possibilities of its application in nuclear chemistry

    International Nuclear Information System (INIS)

    Eichler, B.; Huebener, S.; Rossbach, H.

    1985-08-01

    Using an empiric model partial molar enthalpies of adsorption of the rare earth metals at zero coverage have been calculated for the adsorbent metals Ti, Fe, Ni, Cu, Zr, Nb, Mo, Rh, Pd, Ag, Ta, W, Re, Ir, Pt, Au as well as Al, Si, Zn, Ge, Cd, and Pb. The electron densities at the boundary of the Wigner-Seitz cells in the rare earth metals, necessary for the calculations, have been derived from the crystal entropies. In some cases the magnetic entropy was considered too. The calculated enthalpies of adsorption are compared with experimental data taken from the literature. The valence state of adsorbed europium and ytterbium is discussed in relation to the nature of the adsorbent metal. (author)

  8. Kinematics of the AM-50 heading machine cutting head

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, W; Bak, K; Klich, R [Politechnika Slaska, Gliwice (Poland). Instytut Mechanizacji Gornictwa

    1987-01-01

    Analyzes motion of the cutter head of the AM-50 heading machine. Two types of head motion are comparatively evaluated: planar motion and spatial motion. The spatial motion consists of the head rotational motion and horizontal or vertical feed motion, while planar motion consists of rotational motion and vertical feed motion. Equations that describe head motion under conditions of cutter vertical or horizontal feed motion are derived. The angle between the cutting speed direction and working speed direction is defined. On the basis of these formulae variations of cutting speed depending on the cutting tool position on a cutter head are calculated. Calculations made for 2 extreme cutting tools show that the cutting speed ranges from 1,205 m/s to 3,512 m/s. 4 refs.

  9. Head First Web Design

    CERN Document Server

    Watrall, Ethan

    2008-01-01

    Want to know how to make your pages look beautiful, communicate your message effectively, guide visitors through your website with ease, and get everything approved by the accessibility and usability police at the same time? Head First Web Design is your ticket to mastering all of these complex topics, and understanding what's really going on in the world of web design. Whether you're building a personal blog or a corporate website, there's a lot more to web design than div's and CSS selectors, but what do you really need to know? With this book, you'll learn the secrets of designing effecti

  10. Head first C#

    CERN Document Server

    Stellman, Andrew

    2008-01-01

    Head First C# is a complete learning experience for object-oriented programming, C#, and the Visual Studio IDE. Built for your brain, this book covers C# 3.0 and Visual Studio 2008, and teaches everything from language fundamentals to advanced topics including garbage collection, extension methods, and double-buffered animation. You'll also master C#'s hottest and newest syntax, LINQ, for querying SQL databases, .NET collections, and XML documents. By the time you're through, you'll be a proficient C# programmer, designing and coding large-scale applications. Every few chapters you will come

  11. Head first C#

    CERN Document Server

    Stellman, Andrew

    2010-01-01

    You want to learn C# programming, but you're not sure you want to suffer through another tedious technical book. You're in luck: Head First C# introduces this language in a fun, visual way. You'll quickly learn everything from creating your first program to learning sophisticated coding skills with C# 4.0, Visual Studio 2010 and .NET 4, while avoiding common errors that frustrate many students. The second edition offers several hands-on labs along the way to help you build and test programs using skills you've learned up to that point. In the final lab, you'll put everything together. From o

  12. Head First Python

    CERN Document Server

    Barry, Paul

    2010-01-01

    Ever wished you could learn Python from a book? Head First Python is a complete learning experience for Python that helps you learn the language through a unique method that goes beyond syntax and how-to manuals, helping you understand how to be a great Python programmer. You'll quickly learn the language's fundamentals, then move onto persistence, exception handling, web development, SQLite, data wrangling, and Google App Engine. You'll also learn how to write mobile apps for Android, all thanks to the power that Python gives you. We think your time is too valuable to waste struggling with

  13. Head First Mobile Web

    CERN Document Server

    Gardner, Lyza; Grigsby, Jason

    2011-01-01

    Despite the huge number of mobile devices and apps in use today, your business still needs a website. You just need it to be mobile. Head First Mobile Web walks you through the process of making a conventional website work on a variety smartphones and tablets. Put your JavaScript, CSS media query, and HTML5 skills to work-then optimize your site to perform its best in the demanding mobile market. Along the way, you'll discover how to adapt your business strategy to target specific devices. Navigate the increasingly complex mobile landscapeTake both technical and strategic approaches to mobile

  14. Reactor vessel head permanent shield

    International Nuclear Information System (INIS)

    Hankinson, M.F.; Leduc, R.J.; Richard, J.W.; Malandra, L.J.

    1989-01-01

    A nuclear reactor is described comprising: a nuclear reactor pressure vessel closure head; control rod drive mechanisms (CRDMs) disposed within the closure head so as to project vertically above the closure head; cooling air baffle means surrounding the control rod drive mechanisms for defining cooling air paths relative to the control rod drive mechanisms; means defined within the periphery of the closure head for accommodating fastening means for securing the closure head to its associated pressure vessel; lifting lugs fixedly secured to the closure head for facilitating lifting and lowering movements of the closure head relative to the pressure vessel; lift rods respectively operatively associated with the plurality of lifting lugs for transmitting load forces, developed during the lifting and lowering movements of the closure head, to the lifting lugs; upstanding radiation shield means interposed between the cooling air baffle means and the periphery of the enclosure head of shielding maintenance personnel operatively working upon the closure head fastening means from the effects of radiation which may emanate from the control rod drive mechanisms and the cooling air baffle means; and connecting systems respectively associated with each one of the lifting lugs and each one of the lifting rods for connecting each one of the lifting rods to a respective one of each one of the lifting lugs, and for simultaneously connecting a lower end portion of the upstanding radiation shield means to each one of the respective lifting lugs

  15. Representation of heading direction in far and near head space

    NARCIS (Netherlands)

    Poljac, E.; Berg, A.V. van den

    2003-01-01

    Manipulation of objects around the head requires an accurate and stable internal representation of their locations in space, also during movements such as that of the eye or head. For far space, the representation of visual stimuli for goal-directed arm movements relies on retinal updating, if eye

  16. Head trauma and CT

    International Nuclear Information System (INIS)

    Samejima, Kanji; Yoshii, Nobuo; Tobari, Chitoshi

    1979-01-01

    In our cases of acute and subacute subdural hematoma, the use of CT was evaluated. In our department of surgery, acute subdural hematoma was found in 46 of 388 patients of head trauma who underwent CT. Acute subdural hematoma, like epidural hematoma was usually visualized as a high-density area along the cranial inner table, and this was easily differenciated from epidural hematoma because of difference in shape from the other. The picture of acute subdural hematoma was occasionally confused with that of intracerebral hematoma or cerebral contusion. Single use of CT does not differenciate subacute subdural hematoma from chronic subdural hematoma. However, CT usually visualized acute hematoma as a high-density area, showing the extent of hematoma. Comparison of the thickness of hematoma with the axis deviation of the median part such as the 3rd cerebral ventricle suggested severity of cerebral edema. CT also revealed bilateral or multiple lesions of cerebral contusion or intracerebral hematoma. (Ueda, J.)

  17. Chryse 'Alien Head'

    Science.gov (United States)

    2005-01-01

    26 January 2004 This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows an impact crater in Chryse Planitia, not too far from the Viking 1 lander site, that to seems to resemble a bug-eyed head. The two odd depressions at the north end of the crater (the 'eyes') may have formed by wind or water erosion. This region has been modified by both processes, with water action occurring in the distant past via floods that poured across western Chryse Planitia from Maja Valles, and wind action common occurrence in more recent history. This crater is located near 22.5oN, 47.9oW. The 150 meter scale bar is about 164 yards long. Sunlight illuminates the scene from the left/lower left.

  18. Lower head failure analysis

    International Nuclear Information System (INIS)

    Rempe, J.L.; Thinnes, G.L.; Allison, C.M.; Cronenberg, A.W.

    1991-01-01

    The US Nuclear Regulatory Commission is sponsoring a lower vessel head research program to investigate plausible modes of reactor vessel failure in order to determine (a) which modes have the greatest likelihood of occurrence during a severe accident and (b) the range of core debris and accident conditions that lead to these failures. This paper presents the methodology and preliminary results of an investigation of reactor designs and thermodynamic conditions using analytic closed-form approximations to assess the important governing parameters in non-dimensional form. Preliminary results illustrate the importance of vessel and tube geometrical parameters, material properties, and external boundary conditions on predicting vessel failure. Thermal analyses indicate that steady-state temperature distributions will occur in the vessel within several hours, although the exact time is dependent upon vessel thickness. In-vessel tube failure is governed by the tube-to-debris mass ratio within the lower head, where most penetrations are predicted to fail if surrounded by molten debris. Melt penetration distance is dependent upon the effective flow diameter of the tube. Molten debris is predicted to penetrate through tubes with a larger effective flow diameter, such as a boiling water reactor (BWR) drain nozzle. Ex-vessel tube failure for depressurized reactor vessels is predicted to be more likely for a BWR drain nozzle penetration because of its larger effective diameter. At high pressures (between ∼0.1 MPa and ∼12 MPa) ex-vessel tube rupture becomes a dominant failure mechanism, although tube ejection dominates control rod guide tube failure at lower temperatures. However, tube ejection and tube rupture predictions are sensitive to the vessel and tube radial gap size and material coefficients of thermal expansion

  19. The head-mounted microscope.

    Science.gov (United States)

    Chen, Ting; Dailey, Seth H; Naze, Sawyer A; Jiang, Jack J

    2012-04-01

    Microsurgical equipment has greatly advanced since the inception of the microscope into the operating room. These advancements have allowed for superior surgical precision and better post-operative results. This study focuses on the use of the Leica HM500 head-mounted microscope for the operating phonosurgeon. The head-mounted microscope has an optical zoom from 2× to 9× and provides a working distance from 300 mm to 700 mm. The headpiece, with its articulated eyepieces, adjusts easily to head shape and circumference, and offers a focus function, which is either automatic or manually controlled. We performed five microlaryngoscopic operations utilizing the head-mounted microscope with successful results. By creating a more ergonomically favorable operating posture, a surgeon may be able to obtain greater precision and success in phonomicrosurgery. Phonomicrosurgery requires the precise manipulation of long-handled cantilevered instruments through the narrow bore of a laryngoscope. The head-mounted microscope shortens the working distance compared with a stand microscope, thereby increasing arm stability, which may improve surgical precision. Also, the head-mounted design permits flexibility in head position, enabling operator comfort, and delaying musculoskeletal fatigue. A head-mounted microscope decreases the working distance and provides better ergonomics in laryngoscopic microsurgery. These advances provide the potential to promote precision in phonomicrosurgery. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  20. Modular reactor head shielding system

    International Nuclear Information System (INIS)

    Jacobson, E. B.

    1985-01-01

    An improved modular reactor head shielding system is provided that includes a frame which is removably assembled on a reactor head such that no structural or mechanical alteration of the head is required. The shielding system also includes hanging assemblies to mount flexible shielding pads on trolleys which can be moved along the frame. The assemblies allow individual pivoting movement of the pads. The pivoting movement along with the movement allowed by the trolleys provides ease of access to any point on the reactor head. The assemblies also facilitate safe and efficient mounting of the pads directly to and from storage containers such that workers have additional shielding throughout virtually the entire installation and removal process. The flexible shielding pads are designed to interleave with one another when assembled around the reactor head for substantially improved containment of radiation leakage

  1. Stereotactic Body Radiotherapy for Head and Neck Tumors

    Science.gov (United States)

    2016-04-18

    Squamous Cell Carcinoma of the Head and Neck; Nasopharyngeal Carcinoma; Salivary Gland Cancer; Head and Neck Sarcoma; Paraganglioma of Head and Neck; Chordoma of Head and Neck; Chondrosarcoma of Head and Neck; Angiofibroma of Head and Neck

  2. Turbidity Current Head Mixing

    Science.gov (United States)

    Hernandez, David; Sanchez, Miguel Angel; Medina, Pablo

    2010-05-01

    A laboratory experimental set - up for studying the behaviour of sediment in presence of a turbulent field with zero mean flow is compared with the behaviour of turbidity currents [1] . Particular interest is shown on the initiation of sediment motion and in the sediment lift - off. The behaviour of the turbidity current in a flat ground is compared with the zero mean flow oscilating grid generated turbulence as when wave flow lifts off suspended sediments [2,3]. Some examples of the results obtained with this set-up relating the height of the head of the turbidity current to the equilibrium level of stirred lutoclines are shown. A turbulent velocity u' lower than that estimated by the Shield diagram is required to start sediment motion. The minimum u' required to start sediment lift - off, is a function of sediment size, cohesivity and resting time. The lutocline height depends on u', and the vorticity at the lutocline seems constant for a fixed sediment size [1,3]. Combining grid stirring and turbidty current head shapes analyzed by means of advanced image analysis, sediment vertical fluxes and settling speeds can be measured [4,5]. [1] D. Hernandez Turbulent structure of turbidity currents and sediment transport Ms Thesis ETSECCPB, UPC. Barcelona 2009. [2] A. Sánchez-Arcilla; A. Rodríguez; J.C. Santás; J.M. Redondo; V. Gracia; R. K'Osyan; S. Kuznetsov; C. Mösso. Delta'96 Surf-zone and nearshore measurements at the Ebro Delta. A: International Conference on Coastal Research through large Scale Experiments (Coastal Dynamics '97). University of Plymouth, 1997, p. 186-187. [3] P. Medina, M. A. Sánchez and J. M. Redondo. Grid stirred turbulence: applications to the initiation of sediment motion and lift-off studies Physics and Chemistry of the Earth, Part B: Hydrology, Oceans and Atmosphere. 26, Issue 4, 2001, Pages 299-304 [4] M.O. Bezerra, M. Diez, C. Medeiros, A. Rodriguez, E. Bahia., A. Sanchez-Arcilla and J.M. Redondo. Study on the influence of waves on

  3. Femoral head necrosis; Hueftkopfnekrose

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, J.; Scheurecker, G.; Scheurecker, A.; Stoeger, A.; Huber, A. [Roentgeninstitut am Schillerpark, Linz (Austria); Hofmann, S. [Orthopaedisches Landeskrankenhaus Stolzalpe (Austria)

    2009-05-15

    The epidemiology and pathohistogenesis of avascular femoral head necrosis has still not been clarified in detail. Because the course of the disease runs in stages and over a long time period nearly always culminates in the necessity for a total hip prosthesis, an exact radiological evaluation is of paramount importance for the treatment. There is a need for a common staging system to enable comparison of different therapy concepts and especially their long-term results. In this article the ARCO staging system is described in full detail, which includes all radiological modalities as well as histopathological alterations. (orig.) [German] Bei der avaskulaeren Femurkopfnekrose handelt es sich um ein Krankheitsbild, dessen Ursachen noch immer nicht vollstaendig geklaert sind. Da die Erkrankung stadienhaft verlaeuft und ueber einen laengeren Zeitraum betrachtet nahezu immer in einem prothetischen Hueftersatz muendet, ist eine genaue radiologische Abklaerung fuer die Behandlung von enormer Bedeutung. Um Langzeiterfolge verschiedener Therapiekonzepte vergleichen zu koennen, sind eine exakte Beschreibung und darauf basierend die Verwendung einer einheitlichen Stadieneinteilung wuenschenswert. In der vorliegenden Arbeit wird die ARCO-Stadieneinteilung im Detail beschrieben, die alle bildgebenden Methoden beruecksichtigt und histopathologische Veraenderungen mit einbezieht. (orig.)

  4. Head trauma and CT

    International Nuclear Information System (INIS)

    Samejima, Kanji; Yoshii, Nobuo; Tobari, Chitoshi

    1979-01-01

    It has been said that chronic subdural hematoma cannot be diagnosed by CT. In our cases, CT was used, and the results were described. According to the density of the picture, CT findings of chronic subdural hematoma could be classified into 3 types, those of higher density than that of the cerebral paranchyma, those of isodensity, and those of lower density than that of the cerebral parenchyma. The difference among them appeared to be due to variation in the fluid in hematoma, especially that in hemoglobin concentration. Chronic subdural hematoma was found in 27 of 388 cases of head trauma in which CT was undertaken in our department of surgery for last 2 years. It is difficult to differenciate this disease from subdural edema or subarachnoideal retention of the cerebrospinal fluid. In many cases, use of contrast medium added no change to the CT picture. Cerebral angiography is necessary for definite diagnosis of the disease. Chronic subdural hematoma gives more varieties of findings than other intracranial hematomas. However, if the film is very carefully read, CT is still useful for diagnosing this disease in spite of initially remarked difficulties. (Ueda, J.)

  5. Anaphylaxis Due to Head Injury

    Directory of Open Access Journals (Sweden)

    Bruner, Heather C.

    2015-05-01

    Full Text Available Both anaphylaxis and head injury are often seen in the emergency department, but they are rarely seen in combination. We present a case of a 30-year-old woman who presented with anaphylaxis with urticaria and angioedema following a minor head injury. The patient responded well to intramuscular epinephrine without further complications or airway compromise. Prior case reports have reported angioedema from hereditary angioedema during dental procedures and maxillofacial surgery, but there have not been any cases of first-time angioedema or anaphylaxis due to head injury. [West J Emerg Med. 2015;16(3:435–437.

  6. Anaphylaxis due to head injury.

    Science.gov (United States)

    Bruner, Heather C; Bruner, David I

    2015-05-01

    Both anaphylaxis and head injury are often seen in the emergency department, but they are rarely seen in combination. We present a case of a 30-year-old woman who presented with anaphylaxis with urticaria and angioedema following a minor head injury. The patient responded well to intramuscular epinephrine without further complications or airway compromise. Prior case reports have reported angioedema from hereditary angioedema during dental procedures and maxillofacial surgery, but there have not been any cases of first-time angioedema or anaphylaxis due to head injury.

  7. Boxing-related head injuries.

    Science.gov (United States)

    Jayarao, Mayur; Chin, Lawrence S; Cantu, Robert C

    2010-10-01

    Fatalities in boxing are most often due to traumatic brain injury that occurs in the ring. In the past 30 years, significant improvements in ringside and medical equipment, safety, and regulations have resulted in a dramatic reduction in the fatality rate. Nonetheless, the rate of boxing-related head injuries, particularly concussions, remains unknown, due in large part to its variability in clinical presentation. Furthermore, the significance of repeat concussions sustained when boxing is just now being understood. In this article, we identify the clinical manifestations, pathophysiology, and management of boxing-related head injuries, and discuss preventive strategies to reduce head injuries sustained by boxers.

  8. Head-positioning scintillation camera and head holder therefor

    International Nuclear Information System (INIS)

    Kay, T.D.

    1976-01-01

    A holder for immobilizing the head of a patient undergoing a vertex brain scan by a Gamma Scintillation Camera is described. The holder has a uniquely designed shape capable of comfortably supporting the head. In addition, this holder can be both adjustably and removably utilized in combination with the scintillation camera so as to enable the brain scan operation to take place while the patient is in the seated position

  9. Head and Neck Cancer

    International Nuclear Information System (INIS)

    Tomita, Toshiki; Imanishi, Yorihisa

    2008-01-01

    The limitation of concurrent chemo-radiotherapy (CCRT) in head and neck cancer (HNC) as the primary treatment is described based on recent findings. Limits in the application/indication involve factors of age, performance status (PS) and renal function. The first is that, as deaths in >71 years old patients are derived from other causes (41%) than HNC, CCRT is only useful for younger population; the second, patients with PS 0-1 or Karnofsky performance score >60-70 can be indicated; and third, contraindicated are those with creatinine clearance (CCr) <60 mL/min as the key drug cisplatin in CCRT has a high renal toxicity. It should be recognized that completion rates of chemotherapy and RT are as low as 66-85% and 84-92%, respectively, in CCRT. CCRT has such limiting adverse events as mucitis, dry mouth, dysohagia, weight loss, neutropenia, sepsis, etc., which are most important in CCRT application. CCRT is recommended for the primary cancers of larynx and hypopharynx because they are significantly better conserved than middle pharyngeal, oral and upper jaw cancers. Evidence of CCRT is poor for cancers in paranasal sinuses. Planned neck dissection (PND) is for the cervical metastatic lymph nodes and conducted 6-12 weeks after CCRT regardless to its outcome. In fluorodeoxyglucose-positron emission tomography (FDG-PET) negative cases, PND can be omitted. Necessity of PND is possibly inversely proportional to CCRT intensity performed. For control of remote metastasis, CCRT has obvious limits and inductive chemotherapy before it is currently considered. Salvage surgery post CCRT does not always yield a relief because of complication. Patients with advanced laryngeal cancer can be selected either to surgery or CCRT depending on results of the inductive chemotherapy. To predict the sensitivity to CCRT, some biomarkers like HPV, EGFR and VEGF have been suggested to be useful by retrospective studies. Understanding the limitation is as important as knowing the usefulness in

  10. Sports-related Head Injury

    Science.gov (United States)

    ... and head gear come in many sizes and styles for many sports and must properly fit to ... to play or practice." The "Concussion Diagnosis and Management" section details circumstances in which an athlete should ...

  11. Heater head for stirling engine

    Science.gov (United States)

    Corey, John A.

    1985-07-09

    A monolithic heater head assembly which augments cast fins with ceramic inserts which narrow the flow of combustion gas and obtains high thermal effectiveness with the assembly including an improved flange design which gives greater durability and reduced conduction loss.

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... it may cause some medical devices to malfunction. Most orthopedic implants pose no risk, but you should ... a digital cloud server. Currently, MRI is the most sensitive imaging test of the head (particularly the ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... and may add approximately 15 minutes to the total exam time. top of page What will I ... the limitations of MRI of the Head? High-quality images are assured only if you are able ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the head (particularly the brain) in routine clinical practice. top of page What are some common uses ... gadolinium contrast material except when absolutely necessary for medical treatment. See the MRI Safety page for more ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants pose no ... Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. ...

  16. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... Oral Surgeries Facial Cosmetic Surgery Facial Injury / Trauma Surgery Obstructive Sleep Apnea (OSA) Oral, Head and Neck Pathology TMJ and Facial Pain Wisdom Teeth Management Procedures Anesthesia Anesthesia Oral and maxillofacial surgeons are ...

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org : Radiation Therapy for Brain Tumors Radiation Therapy for ... Imaging (MRI) - Head Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  18. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... It can also invite bacteria that lead to gum disease. Click here to find out more. Who We ... It can also invite bacteria that lead to gum disease. Click here to find out more. Oral, Head ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the head (particularly the brain) in routine clinical practice. top of page What are some common uses ... may follow your regular daily routine and take food and medications as usual. Some MRI examinations may ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... practice. top of page What are some common uses of the procedure? MR imaging of the head ... gadolinium contrast, it may still be possible to use it after appropriate pre-medication. Patient consent will ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... or headphones during the exam. MRI scanners are air-conditioned and well-lit. Music may be played ... the limitations of MRI of the Head? High-quality images are assured only if you are able ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... practice. top of page What are some common uses of the procedure? MR imaging of the head ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ...

  3. American Head and Neck Society

    Science.gov (United States)

    ... research and insights. Comments This field is for validation purposes and should be left unchanged. This iframe ... and Announcements Copyright ©2016 · American Head and Neck Society · Privacy and Return Policy Managed by BSC Management, ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... practice. top of page What are some common uses of the procedure? MR imaging of the head ... for immediate assistance. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI) of the head uses a powerful magnetic field, radio waves and a computer to produce detailed ... there’s a possibility you are pregnant. The magnetic field is not harmful, but it may cause some ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... by the interpreting radiologist. Frequently, the differentiation of abnormal (diseased) tissue from normal tissues is better with ... Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... medically necessary. MRI may not always distinguish between cancer tissue and fluid, known as edema . MRI typically ... Brain Tumors Radiation Therapy for Head and Neck Cancer Others : American Stroke Association National Stroke Association top ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a computer to produce detailed pictures of the brain and other cranial structures that are clearer and ... sensitive imaging test of the head (particularly the brain) in routine clinical practice. top of page What ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... practice. top of page What are some common uses of the procedure? MR imaging of the head ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... page Additional Information and Resources RTAnswers.org : Radiation Therapy for Brain Tumors Radiation Therapy for Head and ...

  11. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... teeth or become infected. It can also invite bacteria that lead to gum disease. Click here to find out ... and surgically treating cancer of the head, neck and mouth. The Oral Cancer Foundation estimates that close to ...

  12. Eye-based head gestures

    DEFF Research Database (Denmark)

    Mardanbegi, Diako; Witzner Hansen, Dan; Pederson, Thomas

    2012-01-01

    A novel method for video-based head gesture recognition using eye information by an eye tracker has been proposed. The method uses a combination of gaze and eye movement to infer head gestures. Compared to other gesture-based methods a major advantage of the method is that the user keeps the gaze...... mobile phone screens. The user study shows that the method detects a set of defined gestures reliably.......A novel method for video-based head gesture recognition using eye information by an eye tracker has been proposed. The method uses a combination of gaze and eye movement to infer head gestures. Compared to other gesture-based methods a major advantage of the method is that the user keeps the gaze...

  13. Topiramate Responsive Exploding Head Syndrome

    OpenAIRE

    Palikh, Gaurang M.; Vaughn, Bradley V.

    2010-01-01

    Exploding head syndrome is a rare phenomenon but can be a significant disruption to quality of life. We describe a 39-year-old female with symptoms of a loud bang and buzz at sleep onset for 3 years. EEG monitoring confirmed these events occurred in transition from stage 1 sleep. This patient reported improvement in intensity of events with topiramate medication. Based on these results, topiramate may be an alternative method to reduce the intensity of events in exploding head syndrome.

  14. Topiramate responsive exploding head syndrome.

    Science.gov (United States)

    Palikh, Gaurang M; Vaughn, Bradley V

    2010-08-15

    Exploding head syndrome is a rare phenomenon but can be a significant disruption to quality of life. We describe a 39-year-old female with symptoms of a loud bang and buzz at sleep onset for 3 years. EEG monitoring confirmed these events occurred in transition from stage 1 sleep. This patient reported improvement in intensity of events with topiramate medication. Based on these results, topiramate may be an alternative method to reduce the intensity of events in exploding head syndrome.

  15. Ghost Head Nebula

    Science.gov (United States)

    1999-01-01

    Looking like a colorful holiday card, a new image from NASA's Hubble Space Telescope reveals a vibrant green and red nebula far from Earth. The image of NGC 2080, taken by Hubble's Wide Field and Planetary Camera 2, designed and built by NASA's Jet Propulsion Laboratory, Pasadena, Calif., is available online at http://www.jpl.nasa.gov/images/wfpc . Images like this help astronomers investigate star formation in nebulas. NGC 2080, nicknamed 'The Ghost Head Nebula,' is one of a chain of star-forming regions lying south of the 30 Doradus nebula in the Large Magellanic Cloud. 30 Doradus is the largest star-forming complex in the local group of galaxies. This 'enhanced color' picture is composed of three narrow-band-filter images obtained by Hubble on March 28, 2000. The red and blue light come from regions of hydrogen gas heated by nearby stars. The green light on the left comes from glowing oxygen. The energy to illuminate the green light is supplied by a powerful stellar wind, a stream of high-speed particles coming from a massive star just outside the image. The central white region is a combination of all three emissions and indicates a core of hot, massive stars in this star-formation region. Intense emission from these stars has carved a bowl-shaped cavity in surrounding gas. In the white region, the two bright areas (the 'eyes of the ghost') - named A1 (left) and A2 (right) -- are very hot, glowing 'blobs' of hydrogen and oxygen. The bubble in A1 is produced by the hot, intense radiation and powerful stellar wind from one massive star. A2 contains more dust and several hidden, massive stars. The massive stars in A1 and A2 must have formed within the last 10,000 years, since their natal gas shrouds are not yet disrupted by the powerful radiation of the newborn stars. The Space Telescope Science Institute is operated by the Association of Universities for Research in Astronomy, Inc., for NASA, under contract with the Goddard Space Flight Center, Greenbelt, Md. The

  16. Heading for a fall? Management of head injury in infants.

    LENUS (Irish Health Repository)

    Williamson, M

    2010-09-01

    Head injury is one of the commonest reasons for infants (< 1 year) to attend the Emergency Department (ED). Clinical management varies considerably and concern about non accidental injury results in a high admission rate in some hospitals. Information was obtained on 103 children under one year of age presenting to the ED with head injury in a prospective study. The average age was 6.7 months and 57% of patients were male. Twenty eight babies had skull x rays with 1 skull fracture diagnosed. None required CT brain scan. Ninety eight (94%) were discharged home from the ED. There were no unplanned returns, readmissions or adverse events. The incidence of traumatic brain injury in children under one year of age presenting with head injury is low and the majority can be safely discharged home.

  17. Wheelchair control by head motion

    Directory of Open Access Journals (Sweden)

    Pajkanović Aleksandar

    2013-01-01

    Full Text Available Electric wheelchairs are designed to aid paraplegics. Unfortunately, these can not be used by persons with higher degree of impairment, such as quadriplegics, i.e. persons that, due to age or illness, can not move any of the body parts, except of the head. Medical devices designed to help them are very complicated, rare and expensive. In this paper a microcontroller system that enables standard electric wheelchair control by head motion is presented. The system comprises electronic and mechanic components. A novel head motion recognition technique based on accelerometer data processing is designed. The wheelchair joystick is controlled by the system’s mechanical actuator. The system can be used with several different types of standard electric wheelchairs. It is tested and verified through an experiment performed within this paper.

  18. OCULAR MANIFESTATIONS OF HEAD INJURIES

    Directory of Open Access Journals (Sweden)

    Kanukollu Venkata Madusudana Rao

    2016-12-01

    Full Text Available BACKGROUND This prospective study aimed to evaluate the incidence of ocular manifestations in head injury and their correlation with the intracranial lesions. MATERIALS AND METHODS A total of 108 consecutive cases of closed head injury admitted in the neurosurgical ward of a tertiary teaching hospital underwent a thorough ophthalmic assessment. Clinical examination, radiological imaging and Glasgow Coma Scale (GCS were applied to grade the severity of injury. RESULTS Total number of 108 patients of head injury were examined of which 38 patients had ocular manifestations (35.18%. Of these, 85.18% were males, 84% of injuries were due to road traffic accidents and 16% were due to fall from a height. The ocular manifestations were as follows- Orbital complications were seen in 6 patients (15.8%. Anterior segment manifestations included black eyes seen in 10 patients (26.3%, subconjunctival haemorrhage in 10.5% of patients (4 patients, corneal involvement in 21% of patients (8 patients and pupillary involvement in 50% of patients (19 patients. Posterior segment manifestations were seen in 26.3% of patients (10 patients and were as follows- Purtscher’s retinopathy in 2 patients and optic atrophy in 5 patients. Cranial nerve palsies were seen in 15 patients (39.47% and supranuclear movement disorders were seen in 3 patients (8%. CONCLUSION Even though, neurosurgeons perform comprehensive clinical examination including eye examination, the main purpose is limited to aid topical diagnosis of neurological lesions. This study emphasises the importance of a detailed eye examination by an ophthalmologist to prevent irreversible visual loss in addition to aiding in the neurological diagnosis. Pupillary involvement, papilloedema and ocular motor paresis pointed to a more severe head injury. This observational prospective study helped us to correlate the severity of head injuries in association with ocular findings in patients admitted in neurosurgical ward

  19. Head First 2D Geometry

    CERN Document Server

    Fallow), Stray

    2009-01-01

    Having trouble with geometry? Do Pi, The Pythagorean Theorem, and angle calculations just make your head spin? Relax. With Head First 2D Geometry, you'll master everything from triangles, quads and polygons to the time-saving secrets of similar and congruent angles -- and it'll be quick, painless, and fun. Through entertaining stories and practical examples from the world around you, this book takes you beyond boring problems. You'll actually use what you learn to make real-life decisions, like using angles and parallel lines to crack a mysterious CSI case. Put geometry to work for you, and

  20. Ophthalmic manifestations of head injury.

    Science.gov (United States)

    Kowal, L

    1992-02-01

    Head injuries are frequently associated with ophthalmic problems. The commonest problems seen in this series of 161 patients with head injury were problems with poor accommodation (16% of patients; 58% of these persisted), convergence (14% of patients; 35% of these persisted), pseudomyopia (19%; 55% persisted) and optic atrophy (26% of the patients; 78% of these were mild and easily missed on routine testing, and 22% were severe). Motility disorders were common, especially cranial nerve palsies. Other less frequent motility disturbances included apparent inferior oblique palsy, comitant esotropia, and exotropia which was often of the convergence insufficiency type.

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... examination poses almost no risk to the average patient when appropriate safety guidelines are followed. If sedation is used, there ... have a personal story about radiology? Share your patient story here Images ... Disease Head Injury Brain Tumors Images related ...

  2. Womanhood in Bessie Head's fiction

    African Journals Online (AJOL)

    Rain Cloud~· Gather ( 1969), Maru ( 1972) and A Question of Power ( 1974 ),. Head addresses and ... Yet as is the case in most literature by black women from Africa and the. Caribbean .... womanhood comes into play in the principal's decision to get rid of her: "she ... which tl}e principal intends to use to his advantage.

  3. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... cancer of the head, neck and mouth. The Oral Cancer Foundation estimates that close to 42,000 Americans ... diagnosed with oral or pharyngeal cancer this year. Oral cancer’s mortality is particularly high, not because it is ...

  4. Blunt Head Trauma and Headache

    Directory of Open Access Journals (Sweden)

    Ana B Chelse

    2015-04-01

    Full Text Available Investigators from New York Presbyterian Morgan Stanley Children’s Hospital examined whether having an isolated headache following minor blunt head trauma was suggestive of traumatic brain injury (TBI among a large cohort of children 2-18 years of age.

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... very early stage by mapping the motion of water molecules in the tissue. This water motion, known as diffusion, is impaired by most ... the limitations of MRI of the Head? High-quality images are assured only if you are able ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... structures of the brain and can also provide functional information (fMRI) in selected cases. MR images of ... Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... of which shows a thin slice of the body. The images can then be studied from different angles by ... information please consult the ACR Manual on Contrast Media and its references. top of page What are the limitations of MRI of the Head? High-quality images are assured only if you are able to ...

  8. Return of the talking heads

    DEFF Research Database (Denmark)

    Reinecke Hansen, Kenneth; Bro, Peter; Andersson, Ralf

    2016-01-01

    . In order to analyze the latest development entering the third wave, we propose a theoretically based dramaturgical model for the television news item. The analysis concludes that, with the current ‘return’ of the talking heads format, the pre-produced and pre-packaged bulletin program about past events...

  9. Head, Neck, and Oral Cancer

    Medline Plus

    Full Text Available ... Oral, Head and Neck Pathology TMJ and Facial Pain Wisdom Teeth Management Procedures Anesthesia Anesthesia Oral and maxillofacial surgeons are ... more. TMJ and Facial Pain TMJ and Facial ... Teeth Management Wisdom Teeth Management An impacted wisdom tooth can ...

  10. Head Start Center Design Guide.

    Science.gov (United States)

    Administration for Children, Youth, and Families (DHHS), Washington, DC. Head Start Bureau.

    This guide contains suggested criteria for planning, designing, and renovating Head Start centers so that they are safe, child-oriented, developmentally appropriate, beautiful, environmentally sensitive, and functional. The content is based on the U.S. General Services Administration's Child Care Center Design Guide, PBS-P140, which was intended…

  11. Analytical modelling of soccer heading

    Indian Academy of Sciences (India)

    ... game is that the players are permitted to use their head to direct the ball during ... method in assessing the cognitive functions that can be applied not only to ... It is attached to a spring (stiffness, k1) and a dashpot (damping coefficient, c1).

  12. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the head uses a powerful magnetic field, radio waves and a computer to produce detailed pictures of the brain and other cranial structures that are clearer and more detailed than other imaging methods. This exam does not use ionizing radiation and may require an injection of a ...

  13. Preschool Facilities - MDC_HeadStart

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — A label (point) feature class of Head Start / Early Head Start/ Delegate Agencies/ Child Care Partnership & Family Day Care Homes Programs location in Miami-Dade...

  14. Heads Up to High School Sports

    Science.gov (United States)

    ... submit" value="Submit" /> HEADS UP to School Sports Recommend on Facebook Tweet Share Compartir To help ... organizations, developed the HEADS UP: Concussion in School Sports initiative and materials. Specific Concussion Information for... Coaches ...

  15. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... with HEADS UP & CDC's Injury Center HEADS UP Resources File Formats Help: How do I view different ... 6348 Email CDC-INFO U.S. Department of Health & Human Services HHS/Open USA.gov Top

  16. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Submit Button Connect with HEADS UP & CDC's Injury Center HEADS UP Resources File Formats Help: How do ... Page last updated: April 24, 2017 Content source: Centers for Disease Control and Prevention , National Center for ...

  17. Head and Neck Cancer—Patient Version

    Science.gov (United States)

    Head and neck cancers include cancers in the larynx (voice box), throat, lips, mouth, nose, and salivary glands. Start here to find information on head and neck cancer treatment in adults and children, causes and prevention, screening, research, and statistics.

  18. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Training course: This page has moved Recommend on Facebook Tweet Share Compartir This training course has been ... with HEADS UP & CDC's Injury Center HEADS UP Resources ... HHS/Open USA.gov Top

  19. Head stabilization in whooping cranes

    Science.gov (United States)

    Kinloch, M.R.; Cronin, T.W.; Olsen, Glenn H.; Chavez-Ramirez, Felipe

    2005-01-01

    The whooping crane (Grus americana) is the tallest bird in North America, yet not much is known about its visual ecology. How these birds overcome their unusual height to identify, locate, track, and capture prey items is not well understood. There have been many studies on head and eye stabilization in large wading birds (herons and egrets), but the pattern of head movement and stabilization during foraging is unclear. Patterns of head movement and stabilization during walking were examined in whooping cranes at Patuxent Wildlife Research Center, Laurel, Maryland USA. Four whooping cranes (1 male and 3 females) were videotaped for this study. All birds were already acclimated to the presence of people and to food rewards. Whooping cranes were videotaped using both digital and Hi-8 Sony video cameras (Sony Corporation, 7-35 Kitashinagawa, 6-Chome, Shinagawa-ku, Tokyo, Japan), placed on a tripod and set at bird height in the cranes' home pens. The cranes were videotaped repeatedly, at different locations in the pens and while walking (or running) at different speeds. Rewards (meal worms, smelt, crickets and corn) were used to entice the cranes to walk across the camera's view plane. The resulting videotape was analyzed at the University of Maryland at Baltimore County. Briefly, we used a computerized reduced graphic model of a crane superimposed over each frame of analyzed tape segments by means of a custom written program (T. W. Cronin, using C++) with the ability to combine video and computer graphic input. The speed of the birds in analyzed segments ranged from 0.30 m/s to 2.64 m/s, and the proportion of time the head was stabilized ranged from 79% to 0%, respectively. The speed at which the proportion reached 0% was 1.83 m/s. The analyses suggest that the proportion of time the head is stable decreases as speed of the bird increases. In all cases, birds were able to reach their target prey with little difficulty. Thus when cranes are walking searching for food

  20. 29 CFR 1918.103 - Head protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Head protection. 1918.103 Section 1918.103 Labor... must ensure that head protection complies with any of the following consensus standards: (i) ANSI Z89.1... as head protection devices that are constructed in accordance with one of the above consensus...

  1. 29 CFR 1915.155 - Head protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Head protection. 1915.155 Section 1915.155 Labor... helmets. (1) Head protection must comply with any of the following consensus standards: (i) ANSI Z89.1... as head protection devices that are constructed in accordance with one of the above consensus...

  2. 29 CFR 1910.135 - Head protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 5 2010-07-01 2010-07-01 false Head protection. 1910.135 Section 1910.135 Labor... head protection. (1) Head protection must comply with any of the following consensus standards: (i... consensus standards will be deemed to be in compliance with the requirements of this section. [59 FR 16362...

  3. Small head size after atomic irradiation

    International Nuclear Information System (INIS)

    Miller, R.W.; Mulvihill, J.J.

    1975-01-01

    A study of children exposed to nuclear explosions in Hiroshima and Nagasaki showed small head size and mental retardation when exposure occurred less than 18 weeks of gestational age. Increased frequency of small head size occurred when maternal exposure was 10 to 19 rad. Tables and graphs are presented to show relationships between dose, gestational age, and frequency of small head size

  4. Health Coordination Manual. Head Start Health Services.

    Science.gov (United States)

    Administration for Children, Youth, and Families (DHHS), Washington, DC. Head Start Bureau.

    Part 1 of this manual on coordinating health care services for Head Start children provides an overview of what Head Start health staff should do to meet the medical, mental health, nutritional, and/or dental needs of Head Start children, staff, and family members. Offering examples, lists, action steps, and charts for clarification, part 2…

  5. 21 CFR 868.1930 - Stethoscope head.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Stethoscope head. 868.1930 Section 868.1930 Food... DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1930 Stethoscope head. (a) Identification. A stethoscope head is a weighted chest piece used during anesthesia to listen to a patient's heart, breath, and...

  6. 29 CFR 1926.100 - Head protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Head protection. 1926.100 Section 1926.100 Labor... § 1926.100 Head protection. (a) Employees working in areas where there is a possible danger of head... protected by protective helmets. (b) Helmets for the protection of employees against impact and penetration...

  7. Fuel rod pellet loading head

    International Nuclear Information System (INIS)

    Howell, T.E.

    1975-01-01

    An assembly for loading nuclear fuel pellets into a fuel rod comprising a loading head for feeding pellets into the open end of the rod is described. The pellets rest in a perforated substantially V-shaped seat through which air may be drawn for removal of chips and dust. The rod is held in place in an adjustable notched locator which permits alignment with the pellets

  8. Bottom head failure program plan

    International Nuclear Information System (INIS)

    Meyer, R.O.

    1989-01-01

    Earlier this year the NRC staff presented a Revised Severe Accident Research Program Plan (SECY-89-123) to the Commission and initiated work on that plan. Two of the near-term issues in that plan involve failure of the bottom head of the reactor pressure vessel. These two issues are (1) depressurization and DCH and (2) BWR Mark I Containment Shell Meltthrough. ORNL has developed models for several competing failure mechanisms for BWRs. INEL has performed analytical and experimental work directly related to bottom head failure in connection with several programs. SNL has conducted a number of analyses and experimental activities to examine the failure of LWR vessels. In addition to the government-sponsored work mentioned above, EPRI and FAI performed studies on vessel failure for the Industry Degraded Core Rulemaking Program (IDCOR). EPRI examined the failure of a PWR vessel bottom head without penetrations, as found in some Combustion Engineering reactors. To give more attention to this subject as called for by the revised Severe Accident Research Plan, two things are being done. First, work previously done is being reviewed carefully to develop an overall picture and to determine the reliability of assumptions used in those studies. Second, new work is being planned for FY90 to try to complete a reasonable understanding of the failure process. The review and planning are being done in close cooperation with the ACRS. Results of this exercise will be presented in this paper

  9. Is Heading in Youth Soccer Dangerous Play?

    Science.gov (United States)

    O'Kane, John W

    2016-01-01

    Soccer is among the most popular youth sports with over 3 million youth players registered in the U.S. Soccer is unique in that players intentionally use their head to strike the ball, leading to concerns that heading could cause acute or chronic brain injury, especially in the immature brains of children. Pub Med search without date restriction was conducted in November 2014 and August 2015 using the terms soccer and concussion, heading and concussion, and youth soccer and concussion. 310 articles were identified and reviewed for applicable content specifically relating to youth athletes, heading, and/or acute or chronic brain injury from soccer. Soccer is a low-risk sport for catastrophic head injury, but concussions are relatively common and heading often plays a role. At all levels of play, concussions are more likely to occur in the act of heading than with other facets of the game. While concussion from heading the ball without other contact to the head appears rare in adult players, some data suggests children are more susceptible to concussion from heading primarily in game situations. Contributing factors include biomechanical forces, less developed technique, and the immature brain's susceptibility to injury. There is no evidence that heading in youth soccer causes any permanent brain injury and there is limited evidence that heading in youth soccer can cause concussion. A reasonable approach based on U.S. Youth Soccer recommendations is to teach heading after age 10 in controlled settings, and heading in games should be delayed until skill acquisition and physical maturity allow the youth player to head correctly with confidence.

  10. First Class Call Stacks: Exploring Head Reduction

    Directory of Open Access Journals (Sweden)

    Philip Johnson-Freyd

    2016-06-01

    Full Text Available Weak-head normalization is inconsistent with functional extensionality in the call-by-name λ-calculus. We explore this problem from a new angle via the conflict between extensionality and effects. Leveraging ideas from work on the λ-calculus with control, we derive and justify alternative operational semantics and a sequence of abstract machines for performing head reduction. Head reduction avoids the problems with weak-head reduction and extensionality, while our operational semantics and associated abstract machines show us how to retain weak-head reduction's ease of implementation.

  11. Porcine head response to blast.

    Science.gov (United States)

    Shridharani, Jay K; Wood, Garrett W; Panzer, Matthew B; Capehart, Bruce P; Nyein, Michelle K; Radovitzky, Raul A; Bass, Cameron R 'dale'

    2012-01-01

    Recent studies have shown an increase in the frequency of traumatic brain injuries related to blast exposure. However, the mechanisms that cause blast neurotrauma are unknown. Blast neurotrauma research using computational models has been one method to elucidate that response of the brain in blast, and to identify possible mechanical correlates of injury. However, model validation against experimental data is required to ensure that the model output is representative of in vivo biomechanical response. This study exposes porcine subjects to primary blast overpressures generated using a compressed-gas shock tube. Shock tube blasts were directed to the unprotected head of each animal while the lungs and thorax were protected using ballistic protective vests similar to those employed in theater. The test conditions ranged from 110 to 740 kPa peak incident overpressure with scaled durations from 1.3 to 6.9 ms and correspond approximately with a 50% injury risk for brain bleeding and apnea in a ferret model scaled to porcine exposure. Instrumentation was placed on the porcine head to measure bulk acceleration, pressure at the surface of the head, and pressure inside the cranial cavity. Immediately after the blast, 5 of the 20 animals tested were apneic. Three subjects recovered without intervention within 30 s and the remaining two recovered within 8 min following respiratory assistance and administration of the respiratory stimulant doxapram. Gross examination of the brain revealed no indication of bleeding. Intracranial pressures ranged from 80 to 390 kPa as a result of the blast and were notably lower than the shock tube reflected pressures of 300-2830 kPa, indicating pressure attenuation by the skull up to a factor of 8.4. Peak head accelerations were measured from 385 to 3845 G's and were well correlated with peak incident overpressure (R(2) = 0.90). One SD corridors for the surface pressure, intracranial pressure (ICP), and head acceleration are

  12. Head position modulates optokinetic nystagmus.

    Science.gov (United States)

    Pettorossi, V E; Ferraresi, A; Botti, F M; Panichi, R; Barmack, N H

    2011-08-01

    Orientation and movement relies on both visual and vestibular information mapped in separate coordinate systems. Here, we examine how coordinate systems interact to guide eye movements of rabbits. We exposed rabbits to continuous horizontal optokinetic stimulation (HOKS) at 5°/s to evoke horizontal eye movements, while they were statically or dynamically roll-tilted about the longitudinal axis. During monocular or binocular HOKS, when the rabbit was roll-tilted 30° onto the side of the eye stimulated in the posterior → anterior (P → A) direction, slow phase eye velocity (SPEV) increased by 3.5-5°/s. When the rabbit was roll-tilted 30° onto the side of the eye stimulated in the A → P direction, SPEV decreased to ~2.5°/s. We also tested the effect of roll-tilt after prolonged optokinetic stimulation had induced a negative optokinetic afternystagmus (OKAN II). In this condition, the SPEV occurred in the dark, "open loop." Modulation of SPEV of OKAN II depended on the direction of the nystagmus and was consistent with that observed during "closed loop" HOKS. Dynamic roll-tilt influenced SPEV evoked by HOKS in a similar way. The amplitude and the phase of SPEV depended on the frequency of vestibular oscillation and on HOKS velocity. We conclude that the change in the linear acceleration of the gravity vector with respect to the head during roll-tilt modulates the gain of SPEV depending on its direction. This modulation improves gaze stability at different image retinal slip velocities caused by head roll-tilt during centric or eccentric head movement.

  13. Essential radiology for head injury

    International Nuclear Information System (INIS)

    Mok, D.W.H.; Kreel, L.

    1988-01-01

    The book covers the guidelines established by the Royal College of Radiologists for the radiographic evaluation of head injuries. It presents a chapter reviewing the normal radiologic anatomy of the skull in six different projections. The advantages and limitations of each projection are addressed. The third chapter, contains 43 radiographs dedicated to the calcified pineal gland and other intracranial calcifications. The book reports on specific types of fractures: linear fractures of the vault, depressed fractures of the vault, fractures in children, fractures of the base of the skull, and fractures of the facial bones

  14. Head First jQuery

    CERN Document Server

    Benedetti, Ryan

    2011-01-01

    Want to add more interactivity and polish to your websites? Discover how jQuery can help you build complex scripting functionality in just a few lines of code. With Head First jQuery, you'll quickly get up to speed on this amazing JavaScript library by learning how to navigate HTML documents while handling events, effects, callbacks, and animations. By the time you've completed the book, you'll be incorporating Ajax apps, working seamlessly with HTML and CSS, and handling data with PHP, MySQL and JSON. If you want to learn-and understand-how to create interactive web pages, unobtrusive scrip

  15. Large diameter metal on metal total hip replacement for femoral neck fractures with neurological conditions A retrospective assessment

    Directory of Open Access Journals (Sweden)

    Jia Li

    2014-01-01

    Conclusion: We believe the use of L-MoM can diminish the rate of instability or dislocation, after operation. The L-MoM is an option for patients with Parkinson′s disease and poliomyelitis with femoral neck fracture.

  16. Clinical Usefulness of SPECT-CT in Patients with an Unexplained Pain in Metal on Metal (MOM) Total Hip Arthroplasty.

    Science.gov (United States)

    Berber, Reshid; Henckel, Johann; Khoo, Michael; Wan, Simon; Hua, Jia; Skinner, John; Hart, Alister

    2015-04-01

    SPECT-CT is increasingly used to assess painful knee arthroplasties. The aim of this study was to evaluate the clinical usefulness of SPECT-CT in unexplained painful MOM hip arthroplasty. We compared the diagnosis and management plan for 19 prosthetic MOM hips in 15 subjects with unexplained pain before and after SPECT-CT. SPECT-CT changed the management decision in 13 (68%) subjects, Chi-Square=5.49, P=0.24. In 6 subjects (32%) pain remained unexplained however the result reassured the surgeon to continue with non-operative management. SPECT-CT should be reserved as a specialist test to help identify possible causes of pain where conventional investigations have failed. It can help reassure surgeons making management decisions for patients with unexplained pain following MOM hip arthroplasty. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Comparison of Metal-on-Metal Hip Simulator Wear Measured by Gravimetric, CMM and Optical Profiling Methods

    OpenAIRE

    Alberts, Larry Russell; Martinez-Nogues, Vanesa; Cook, Richard; Maul, Christian; Bills, Paul J.; Racasan, Radu; Stolz, Martin; Wood, Robert J. K.

    2018-01-01

    Simulation of wear in artificial joint implants is critical for evaluating implant designs and materials. Traditional protocols employ the gravimetric method to determine the loss of material by measuring the weight of the implant components before and after various test intervals and after the completed test. However, the gravimetric method cannot identify the location, area coverage or maximum depth of the wear and it has difficulties with proportionally small weight changes in relatively h...

  18. Geometric factors in f.c.c. and b.c.c. metal-on-metal epitaxy

    International Nuclear Information System (INIS)

    Bruce, L.A.; Jaeger, H.

    1978-01-01

    Deposits of Ni, Au and Ag formed by condensing metal vapour in U.H.V. onto (001)W, held at a temperature Tsub(s) in the range 300K< Tsub(s)<1200 K, always form epitaxial layers. However, while Au and Ag form (001) epitaxial layers of f.c.c. single crystals, (001)d parallel to (001)s with, say, [110]d parallel to [010]s, Ni and Cu occur in two orthogonal domains, each characterized by an exclusive set of fault (or twin) planes. Within a fault plane, atoms are hexagonally close-packed and, within a domain, fault planes are normal to either [1-1-0]s or [1-10]s and a close-packed direction in the planes is normal to the substrate. The lateral stacking of the fault planes may range from random at low values of Tsub(s) to that of, say, (11-1-) planes in heavily faulted and/or twinned (110) epitaxed f.c.c. material, or of basal planes in (110) epitaxed h.c.p. material at high values of Tsub(s). The results are readily explained on the basis of a growth model developed for deposits of Ni and Cu on (001) Ag. (author)

  19. HEAD MOVEMENT DURING WALKING IN THE CAT

    Science.gov (United States)

    ZUBAIR, HUMZA N.; BELOOZEROVA, IRINA N.; SUN, HAI; MARLINSKI, VLADIMIR

    2016-01-01

    Knowledge of how the head moves during locomotion is essential for understanding how locomotion is controlled by sensory systems of the head. We have analyzed head movements of the cat walking along a straight flat pathway in the darkness and light. We found that cats' head left-right translations, and roll and yaw rotations oscillated once per stride, while fore-aft and vertical translations, and pitch rotations oscillated twice. The head reached its highest vertical positions during second half of each forelimb swing, following maxima of the shoulder/trunk by 20–90°. Nose-up rotation followed head upward translation by another 40–90° delay. The peak-to-peak amplitude of vertical translation was ~1.5 cm and amplitude of pitch rotation was ~3°. Amplitudes of lateral translation and roll rotation were ~1 cm and 1.5–3°, respectively. Overall, cats' heads were neutral in roll and 10–30° nose-down, maintaining horizontal semicircular canals and utriculi within 10° of the earth horizontal. The head longitudinal velocity was 0.5–1 m/s, maximal upward and downward linear velocities were ~0.05 and ~0.1 m/s, respectively, and maximal lateral velocity was ~0.05 m/s. Maximal velocities of head pitch rotation were 20–50 °/s. During walking in light, cats stood 0.3–0.5 cm taller and held their head 0.5–2 cm higher than in darkness. Forward acceleration was 25–100% higher and peak-to-peak amplitude of head pitch oscillations was ~20 °/s larger. We concluded that, during walking, the head of the cat is held actively. Reflexes appear to play only a partial role in determining head movement, and vision might further diminish their role. PMID:27339731

  20. 45 CFR 1308.21 - Parent participation and transition of children into Head Start and from Head Start to public...

    Science.gov (United States)

    2010-10-01

    ... into Head Start and from Head Start to public school. 1308.21 Section 1308.21 Public Welfare... AND HUMAN SERVICES THE ADMINISTRATION FOR CHILDREN, YOUTH AND FAMILIES, HEAD START PROGRAM HEAD START... Standards § 1308.21 Parent participation and transition of children into Head Start and from Head Start to...

  1. A pre-Hispanic head.

    Directory of Open Access Journals (Sweden)

    Raffaella Bianucci

    Full Text Available This report on a male head revealed biologic rhythms, as gleaned from hydrogen isotope ratios in hair, consistent with a South-American origin and Atomic Mass Spectrometry radiocarbon dating (AMS compatible with the last pre-Hispanic period (1418-1491 AD, 95.4% probability. Biopsies showed exceptionally well-preserved tissues. The hair contained high levels of toxic elements (lead, arsenic and mercury incompatible with life. There was no evidence for lead deposition in bone consistent with post-mortem accumulation of this toxic element in the hair. We propose that the high content of metals in hair was the result of metabolic activity of bacteria leading to metal complexation in extra cellular polymeric substances (EPS. This is a recognized protective mechanism for bacteria that thrive in toxic environments. This mechanism may account for the tissues preservation and gives a hint at soil composition where the head was presumably buried. Our results have implications for forensic toxicology which has, hitherto, relied on hair analyses as one means to reconstruct pre-mortem metabolism and for detecting toxic elements accumulated during life. Our finding also has implications for other archaeological specimens where similar circumstances may distort the results of toxicological studies.

  2. A pre-Hispanic head.

    Science.gov (United States)

    Bianucci, Raffaella; Jeziorska, Maria; Lallo, Rudy; Mattutino, Grazia; Massimelli, Massimo; Phillips, Genevieve; Appenzeller, Otto

    2008-04-30

    This report on a male head revealed biologic rhythms, as gleaned from hydrogen isotope ratios in hair, consistent with a South-American origin and Atomic Mass Spectrometry radiocarbon dating (AMS) compatible with the last pre-Hispanic period (1418-1491 AD, 95.4% probability). Biopsies showed exceptionally well-preserved tissues. The hair contained high levels of toxic elements (lead, arsenic and mercury) incompatible with life. There was no evidence for lead deposition in bone consistent with post-mortem accumulation of this toxic element in the hair. We propose that the high content of metals in hair was the result of metabolic activity of bacteria leading to metal complexation in extra cellular polymeric substances (EPS). This is a recognized protective mechanism for bacteria that thrive in toxic environments. This mechanism may account for the tissues preservation and gives a hint at soil composition where the head was presumably buried. Our results have implications for forensic toxicology which has, hitherto, relied on hair analyses as one means to reconstruct pre-mortem metabolism and for detecting toxic elements accumulated during life. Our finding also has implications for other archaeological specimens where similar circumstances may distort the results of toxicological studies.

  3. Anatomy of the infant head

    International Nuclear Information System (INIS)

    Bosma, J.F.

    1986-01-01

    This text is mainly an atlas of illustration representing the dissection of the head and upper neck of the infant. It was prepared by the author over a 20-year period. The commentary compares the anatomy of the near-term infant with that of a younger fetus, child, and adult. As the author indicates, the dearth of anatomic information about postnatal anatomic changes represents a considerable handicap to those imaging infants. In part 1 of the book, anatomy is related to physiologic performance involving the pharynx, larynx, and mouth. Sequential topics involve the regional anatomy of the head (excluding the brain), the skeleton of the cranium, the nose, orbit, mouth, larynx, pharynx, and ear. To facilitate use of this text as a reference, the illustrations and text on individual organs are considered separately (i.e., the nose, the orbit, the eye, the mouth, the larynx, the pharynx, and the ear). Each part concerned with a separate organ includes materials from the regional illustrations contained in part 2 and from the skeleton, which is treated in part 3. Also included in a summary of the embryologic and fetal development of the organ

  4. Intention tremor after head injury

    International Nuclear Information System (INIS)

    Iwadate, Yasuo; Saeki, Naokatsu; Namba, Hiroki; Odaki, Masaru; Oka, Nobuo.

    1989-01-01

    Eight cases of intention tremor as a late complication of head injury were investigated. The patients ranged in age from 3 to 24 years. All received severe head injuries and lapsed into coma immediately afterward (Glasgow Coma Scale scores ≤8). Six patients exhibited decerebration or decortication. Hemiparesis was present in six cases and oculomotor nerve palsy in four. In the chronic stage, all patients displayed some degree of impairment of higher cortical function and five had dysarthria and/or ataxia. Initial computed tomography (CT) scans within 3 hours after the injury were obtained in five cases, of which four showed a hemorrhagic lesion in the midbrain or its surroundings. Other CT findings were diffuse cerebral swelling (four cases), intraventricular hemorrhage (three), and multiple hemorrhagic lesions (two). In the chronic stage, generalized cortical atrophy or ventricular enlargement was noted in five cases. These clinical features and CT findings indicate diffuse brain damage as well as midbrain damage and may reflect shearing injury. (author)

  5. Computing camera heading: A study

    Science.gov (United States)

    Zhang, John Jiaxiang

    2000-08-01

    An accurate estimate of the motion of a camera is a crucial first step for the 3D reconstruction of sites, objects, and buildings from video. Solutions to the camera heading problem can be readily applied to many areas, such as robotic navigation, surgical operation, video special effects, multimedia, and lately even in internet commerce. From image sequences of a real world scene, the problem is to calculate the directions of the camera translations. The presence of rotations makes this problem very hard. This is because rotations and translations can have similar effects on the images, and are thus hard to tell apart. However, the visual angles between the projection rays of point pairs are unaffected by rotations, and their changes over time contain sufficient information to determine the direction of camera translation. We developed a new formulation of the visual angle disparity approach, first introduced by Tomasi, to the camera heading problem. Our new derivation makes theoretical analysis possible. Most notably, a theorem is obtained that locates all possible singularities of the residual function for the underlying optimization problem. This allows identifying all computation trouble spots beforehand, and to design reliable and accurate computational optimization methods. A bootstrap-jackknife resampling method simultaneously reduces complexity and tolerates outliers well. Experiments with image sequences show accurate results when compared with the true camera motion as measured with mechanical devices.

  6. Head and neck position sense.

    Science.gov (United States)

    Armstrong, Bridget; McNair, Peter; Taylor, Denise

    2008-01-01

    Traumatic minor cervical strains are common place in high-impact sports (e.g. tackling) and premature degenerative changes have been documented in sports people exposed to recurrent impact trauma (e.g. scrummaging in rugby) or repetitive forces (e.g. Formula 1 racing drivers, jockeys). While proprioceptive exercises have been an integral part of rehabilitation of injuries in the lower limb, they have not featured as prominently in the treatment of cervical injuries. However, head and neck position sense (HNPS) testing and re-training may have relevance in the management of minor sports-related neck injuries, and play a role in reducing the incidence of ongoing pain and problems with function. For efficacious programmes to be developed and tested, fundamental principles associated with proprioception in the cervical spine should be considered. Hence, this article highlights the importance of anatomical structures in the cervical spine responsible for position sense, and how their interaction with the CNS affects our ability to plan and execute effective purposeful movements. This article includes a review of studies examining position sense in subjects with and without pathology and describes the effects of rehabilitation programmes that have sought to improve position sense. In respect to the receptors providing proprioceptive information for the CNS, the high densities and complex arrays of spindles found in cervical muscles suggest that these receptors play a key role. There is some evidence suggesting that ensemble encoding of discharge patterns from muscle spindles is relayed to the CNS and that a pattern recognition system is used to establish joint position and movement. Sensory information from neck proprioceptive receptors is processed in tandem with information from the vestibular system. There are extensive anatomical connections between neck proprioceptive inputs and vestibular inputs. If positional information from the vestibular system is inaccurate or

  7. Ulnar nerve entrapment complicating radial head excision

    Directory of Open Access Journals (Sweden)

    Kevin Parfait Bienvenu Bouhelo-Pam

    Full Text Available Introduction: Several mechanisms are involved in ischemia or mechanical compression of ulnar nerve at the elbow. Presentation of case: We hereby present the case of a road accident victim, who received a radial head excision for an isolated fracture of the radial head and complicated by onset of cubital tunnel syndrome. This outcome could be the consequence of an iatrogenic valgus of the elbow due to excision of the radial head. Hitherto the surgical treatment of choice it is gradually been abandoned due to development of radial head implant arthroplasty. However, this management option is still being performed in some rural centers with low resources. Discussion: The radial head plays an important role in the stability of the elbow and his iatrogenic deformity can be complicated by cubital tunnel syndrome. Conclusion: An ulnar nerve release was performed with favorable outcome. Keywords: Cubital tunnel syndrome, Peripheral nerve palsy, Radial head excision, Elbow valgus

  8. A customized head and neck support system

    International Nuclear Information System (INIS)

    Bentel, Gunilla C.; Marks, Lawrence B.; Sherouse, George W.; Spencer, David P.

    1995-01-01

    Purpose: To describe a customized head and neck immobilization system for patients receiving radiotherapy including a head support that conforms to the posterior contour of the head and neck. Methods: The system includes a customized headrest to support the posterior head and neck. This is fixed to a thermoplastic face mask that molds to the anterior head/face contours. The shape of these customized head and neck supports were compared to 'standard' supports. Results: This system is comfortable for the patients and appears to be effective in reproducing the setup of the treatment. Conclusions: The variability in the size and shape of the customized posterior supports exceeded that of 'standard' headrests. It is our clinical impression that the customized supports improve reproducibility and are now a standard part of our immobilization system. The quantitative analysis of the customized headrests and some commonly used 'standard' headrests suggests that the customized supports are better able to address variabilities in patient shape

  9. Tridimensional pose estimation of a person head

    International Nuclear Information System (INIS)

    Perez Berenguer, Elisa; Soria, Carlos; Nasisi, Oscar; Mut, Vicente

    2007-01-01

    In this work, we present a method for estimating 3-D motion parameters; this method provides an alternative way for 3D head pose estimation from image sequence in the current computer vision literature. This method is robust over extended sequences and large head motions and accurately extracts the orientation angles of head from a single view. Experimental results show that this tracking system works well for development a human-computer interface for people that possess severe motor incapacity

  10. Remediation of attention deficits in head injury.

    OpenAIRE

    Nag S; Rao S

    1999-01-01

    Head injury is associated with psychological sequelae which impair the patient′s psychosocial functioning. Information processing, attention and memory deficits are seen in head injuries of all severity. We attempted to improve deficits of focused, sustained and divided attention. The principle of overlapping sources of attention resource pools was utilised in devising the remediation programme. Tasks used simple inexpensive materials. Four head injured young adult males with post conc...

  11. AHP 47: YELLOW-HEAD HORSE

    Directory of Open Access Journals (Sweden)

    Sangs rgyas bkra shis སངས་རྒྱས་བཀྲ་ཤིས།

    2017-04-01

    Full Text Available My family had a stallion we called Rta mgo ser 'Yellow-Head Horse'. Father and two of his brothers occasionally rode it. Father said that Yellow-Head was very wild when it was taken to join local horseraces. I didn't believe that because Yellow-Head was very gentle when Mother rode it to the local monastery and also when I rode it.

  12. Posture of the head and pharyngeal swallowing

    International Nuclear Information System (INIS)

    Ekberg, O.

    1986-01-01

    Closure of the laryngeal vestibule during swallowing is important for protection of the airways. The present investigation included 53 patients with dysphagia examined cineradiographically with the head held in resting posture, flexion and extension. The ability to protect the airways by the downward movement of the epiglottis and by obliteration of the laryngeal vestibule was studied in different postures of the head. Of 35 patients with normal laryngeal obliteration with the head in resting position 10 showed a defective closure at swallowing in extension. In 18 patients with defective closure of the laryngeal vestibule in resting position 9 were improved on flexion and two on extension of the head. In one patient with defectie closure of the laryngeal vestibule in resting position swallowing in flexion showed an aggravated dysfunction. In our other patients the defective closure became more marked on extension. Four patients had less effective downward movement of the epiglottis with the head in extension. Of 10 patients with defective epiglottic movement with the head in resting position two were improved on tilting the head forwards. The results show that the position of the head influences the closure of the airways during swallowing. Patients with defective protection of the laryngeal vestibule should be instructed to swallow with the head tilted forwards. (orig.)

  13. Multi-head Watson-Crick automata

    OpenAIRE

    Chatterjee, Kingshuk; Ray, Kumar Sankar

    2015-01-01

    Inspired by multi-head finite automata and Watson-Crick automata in this paper, we introduce new structure namely multi-head Watson-Crick automata where we replace the single tape of multi-head finite automaton by a DNA double strand. The content of the second tape is determined using a complementarity relation similar to Watson-Crick complementarity relation. We establish the superiority of our model over multi-head finite automata and also show that both the deterministic and non-determinis...

  14. Radial head button holing: a cause of irreducible anterior radial head dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Su-Mi; Chai, Jee Won; You, Ja Yeon; Park, Jina [Seoul National University Seoul Metropolitan Government Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of); Bae, Kee Jeong [Seoul National University Seoul Metropolitan Government Boramae Medical Center, Department of Orthopedic Surgery, Seoul (Korea, Republic of)

    2016-10-15

    ''Buttonholing'' of the radial head through the anterior joint capsule is a known cause of irreducible anterior radial head dislocation associated with Monteggia injuries in pediatric patients. To the best of our knowledge, no report has described an injury consisting of buttonholing of the radial head through the annular ligament and a simultaneous radial head fracture in an adolescent. In the present case, the radiographic findings were a radial head fracture with anterior dislocation and lack of the anterior fat pad sign. Magnetic resonance imaging (MRI) clearly demonstrated anterior dislocation of the fractured radial head through the torn annular ligament. The anterior joint capsule and proximal portion of the annular ligament were interposed between the radial head and capitellum, preventing closed reduction of the radial head. Familiarity with this condition and imaging findings will aid clinicians to make a proper diagnosis and fast decision to perform an open reduction. (orig.)

  15. Press fit shape femoral heads for acetabular reconstruction - 5 to 8 years results

    International Nuclear Information System (INIS)

    Obenous, C.; Girtler, R.; Schwoger, W.; Winkler, H.

    1999-01-01

    Filling of acetabular defects with allograft bone is a favourable method in revision-THR provided that primary stability and load bearing capability can be achieved. Since 1990 we perform structural allografting in the acetabular area using a special technique. Defects are prepared with hemispherical reamers (male) in order to obtain a smooth concave surface. Deep-frozen femoral heads are then prepared using female shapers of a diameter 0-4mm larger, thus obtaining a convex surface fitting precisely into the prepared bed. In ideal cases a press-fit can be obtained granting primary stability without additional implants, otherwise we secure the grafts against rotation with one or two traction screws in loading-direction. Implantation of the cup is performed like in primary THR, care is taken to place the implant exactly at the anatomically correct position. Weight bearing is performed as soon as after primary THR; due to the technique loads are distributed evenly over the entire contact area to host bone, pressing the graft firmly into its bed. From 1990 to 1993 this method has been used in 179 cases. 104 cases could be followed between 60 and 95 months (average 71,5 months). Mean age at operation was 66,5 years (39-87 vears). Defects were classified according to Gross as cavitary in 15, minor column in 50 and major column in 39 cases. 85x the cup has been cemented, 19x cementless. One uncemented and 7 cemented cups loosened, all within the first 2 years. 6 meanwhile have been revised a second time. Those usually were cases, where the cup was placed in a non-anatomical position and / or the graft was not secured against rotatory forces. In 17 cases we observed slight condensation of the grafts with consequent migration of the implants. Migration usually did not exceed 5mm and no other signs of implant loosening have been associated. Radiographs indicated a unifon-n pattern of rapid graft-incorporation. Remodelling seemed to be completed after the second year, from

  16. Head First WordPress

    CERN Document Server

    Siarto, Jeff

    2010-01-01

    Whether you're promoting your business or writing about your travel adventures, Head First WordPress will teach you not only how to make your blog look unique and attention-grabbing, but also how to dig into the more complex features of WordPress 3.0 to make your website work well, too. You'll learn how to move beyond the standard WordPress look and feel by customizing your blog with your own URL, templates, plugin functionality, and more. As you learn, you'll be working with real WordPress files: The book's website provides pre-fab WordPress themes to download and work with as you follow al

  17. CT of the neonatal head

    International Nuclear Information System (INIS)

    Mohan, S.; Rogan, E.A.; Batty, R.; Raghavan, A.; Whitby, E.H.; Hart, A.R.; Connolly, D.J.A.

    2013-01-01

    Computed tomography (CT) is used less often than other techniques on neonatal units. However, in the acute setting, CT can be invaluable in diagnosing or excluding potentially life-threatening conditions and guiding initial management in neonates. Common indications for scanning include trauma, suspected non-accidental injury, infection, or an acute hypoxic or metabolic event. The aim of this review is to provide an overview of the normal neonatal head at CT and compare this to the common pathological abnormalities. Several key features of each condition will be highlighted. It is important to note that some pathological conditions can have overlapping features at CT and, therefore, the clinical history and additional investigations are also of key importance in determining the diagnosis

  18. Low-head hydro power

    Science.gov (United States)

    Lemer, E. J.

    1980-11-01

    With a view toward increasing the U.S. electric output, the Army Corps of Engineers has estimated that 55 GW can be obtained immediately from new capacity at existing dams and 40 GW more over the long term. Given the long lead times needed to build new dams, most interest has centered on the existing dams. The Corps of Engineers has established that 21 GW can be obtained from hydroelectric and 34 GW from nonpower dams. Existing hydroelectric sites are being expanded by the utilities, but exploitation of the nonpower dams will require governmental encouragement, because the vast majority are low-head sites (dams less than 40 m high). In the present paper, the question of economics and national policy is examined. The advantages which would accrue from substituting axial turbines for the Kaplan turbine are noted.

  19. Natural head position: An overview.

    Science.gov (United States)

    Meiyappan, N; Tamizharasi, S; Senthilkumar, K P; Janardhanan, K

    2015-08-01

    Cephalometrics has given us a different perspective of interpreting various skeletal problems in the dentofacial complex. Natural head position (NHP) is a reproducible, physiologically determined aspect of function. To determine NHP, a horizontal or vertical reference line outside the crania was used, but preference was given generally to the horizontal. Various intra and extracranial cephalometric horizontal reference planes have been used to formulate diagnosis and plan individualized treatment for an integrated correction of the malocclusion cephalometrics is constantly undergoing refinements in its techniques and analyses to improve the clinical applications. Even though various methods for establishing NHP have been proposed, still it remains a challenge to the clinicians to implement the concept of NHP thoroughly in all the stages of treatment because of practical difficulties in the clinical scenario.

  20. Head trauma and CT with special reference to diagnosis of complications of head trauma

    International Nuclear Information System (INIS)

    Samejima, Kanji; Yoshii, Nobuo; Tobari, Chitose

    1979-01-01

    Cases in which CT was useful for the diagnosis of complications of head trauma were reported. First, complications of head trauma were given an outline, and then, cases of protrusion of the brain, traumatic pneumocephalus, and cerebro-vascular disorders caused by head trauma were mentioned. (Tsunoda, M.)

  1. Head impact in a snowboarding accident.

    Science.gov (United States)

    Bailly, N; Llari, M; Donnadieu, T; Masson, C; Arnoux, P J

    2017-09-01

    To effectively prevent sport traumatic brain injury (TBI), means of protection need to be designed and tested in relation to the reality of head impact. This study quantifies head impacts during a typical snowboarding accident to evaluate helmet standards. A snowboarder numerical model was proposed, validated against experimental data, and used to quantify the influence of accident conditions (speed, snow stiffness, morphology, and position) on head impacts (locations, velocities, and accelerations) and injury risk during snowboarding backward falls. Three hundred twenty-four scenarios were simulated: 70% presented a high risk of mild TBI (head peak acceleration >80 g) and 15% presented a high risk of severe TBI (head injury criterion >1000). Snow stiffness, speed, and snowboarder morphology were the main factors influencing head impact metrics. Mean normal head impact speed (28 ± 6 km/h) was higher than equivalent impact speed used in American standard helmet test (ASTM F2040), and mean tangential impact speed, not included in standard tests, was 13.8 (±7 km/h). In 97% of simulated impacts, the peak head acceleration was below 300 g, which is the pass/fail criteria used in standard tests. Results suggest that initial speed, impacted surface, and pass/fail criteria used in helmet standard performance tests do not fully reflect magnitude and variability of snowboarding backward-fall impacts. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. 49 CFR 214.113 - Head protection.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Head protection. 214.113 Section 214.113 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... conform to the national consensus standards for industrial head protection (American National Standards...

  3. Systematic biases in human heading estimation.

    Directory of Open Access Journals (Sweden)

    Luigi F Cuturi

    Full Text Available Heading estimation is vital to everyday navigation and locomotion. Despite extensive behavioral and physiological research on both visual and vestibular heading estimation over more than two decades, the accuracy of heading estimation has not yet been systematically evaluated. Therefore human visual and vestibular heading estimation was assessed in the horizontal plane using a motion platform and stereo visual display. Heading angle was overestimated during forward movements and underestimated during backward movements in response to both visual and vestibular stimuli, indicating an overall multimodal bias toward lateral directions. Lateral biases are consistent with the overrepresentation of lateral preferred directions observed in neural populations that carry visual and vestibular heading information, including MSTd and otolith afferent populations. Due to this overrepresentation, population vector decoding yields patterns of bias remarkably similar to those observed behaviorally. Lateral biases are inconsistent with standard bayesian accounts which predict that estimates should be biased toward the most common straight forward heading direction. Nevertheless, lateral biases may be functionally relevant. They effectively constitute a perceptual scale expansion around straight ahead which could allow for more precise estimation and provide a high gain feedback signal to facilitate maintenance of straight-forward heading during everyday navigation and locomotion.

  4. Clinical features of the exploding head syndrome.

    Science.gov (United States)

    Pearce, J M

    1989-07-01

    Fifty patients suffering from the "exploding head syndrome" are described. This hitherto unreported syndrome is characterised by a sense of an explosive noise in the head usually in the twilight stage of sleep. The associated symptoms are varied, but the benign nature of the condition is emphasised and neither extensive investigation nor treatment are indicated.

  5. Clinical features of the exploding head syndrome.

    OpenAIRE

    Pearce, J M

    1989-01-01

    Fifty patients suffering from the "exploding head syndrome" are described. This hitherto unreported syndrome is characterised by a sense of an explosive noise in the head usually in the twilight stage of sleep. The associated symptoms are varied, but the benign nature of the condition is emphasised and neither extensive investigation nor treatment are indicated.

  6. The Role of the Primary School Head.

    Science.gov (United States)

    Davies, Lester

    1987-01-01

    This study uses Henry Mintzberg's structural observation method to examine British primary school head teachers' work patterns and determine the nature of their role. Head teachers' days were characterized by brevity, variety, and fragmentation similar to those discussed in findings of other empirical managerial studies. Leadership roles stressed…

  7. Elastic plastic buckling of elliptical vessel heads

    International Nuclear Information System (INIS)

    Alix, M.; Roche, R.L.

    1981-08-01

    The risks of buckling of dished vessel head increase when the vessel is thin walled. This paper gives the last results on experimental tests of 3 elliptical heads and compares all the results with some empirical formula dealing with elastic and plastic buckling

  8. Head Start Impact Study. Technical Report

    Science.gov (United States)

    Puma, Michael; Bell, Stephen; Cook, Ronna; Heid, Camilla; Shapiro, Gary; Broene, Pam; Jenkins, Frank; Fletcher, Philip; Quinn, Liz; Friedman, Janet; Ciarico, Janet; Rohacek, Monica; Adams, Gina; Spier, Elizabeth

    2010-01-01

    This Technical Report is designed to provide technical detail to support the analysis and findings presented in the "Head Start Impact Study Final Report" (U.S. Department of Health and Human Services, January 2010). Chapter 1 provides an overview of the Head Start Impact Study and its findings. Chapter 2 provides technical information on the…

  9. Humeral head size in shoulder arthroplasty

    DEFF Research Database (Denmark)

    Vaesel, M T; Olsen, Bo Sanderhoff; Søjbjerg, Jens Ole

    1998-01-01

    Changes in kinematics after hemiarthroplasty of the glenohumeral joint were investigated in nine cadaveric specimens. During experiments the influence of the humeral head size on glenohumeral kinematics was evaluated. A modular prosthesis with five different head sizes and press-fit stems was use...

  10. Motion control of the Twente humanoid head

    NARCIS (Netherlands)

    Visser, L.C.; Carloni, Raffaella; Stramigioli, Stefano

    2009-01-01

    In this work, we present the design and the realization of the motion control algorithm implemented in the Twente hu- manoid head, a seven degrees of freedom (dof) robotic sys- tem. The aim of the project is to have a humanoid head that can serve as a research platform for human-machine interac-

  11. 76 FR 70009 - Head Start Program

    Science.gov (United States)

    2011-11-09

    ... importance of the early years of a child's growth and development. On December 12, 2007, the Improving Head... education, serving nearly one million of our nation's most vulnerable young children and their families. It... Administration for Children and Families 45 CFR Part 1307 Head Start Program; Final Rule #0;#0;Federal Register...

  12. Visual perception of axes of head rotation

    Science.gov (United States)

    Arnoldussen, D. M.; Goossens, J.; van den Berg, A. V.

    2013-01-01

    Registration of ego-motion is important to accurately navigate through space. Movements of the head and eye relative to space are registered through the vestibular system and optical flow, respectively. Here, we address three questions concerning the visual registration of self-rotation. (1) Eye-in-head movements provide a link between the motion signals received by sensors in the moving eye and sensors in the moving head. How are these signals combined into an ego-rotation percept? We combined optic flow of simulated forward and rotational motion of the eye with different levels of eye-in-head rotation for a stationary head. We dissociated simulated gaze rotation and head rotation by different levels of eye-in-head pursuit. We found that perceived rotation matches simulated head- not gaze-rotation. This rejects a model for perceived self-rotation that relies on the rotation of the gaze line. Rather, eye-in-head signals serve to transform the optic flow's rotation information, that specifies rotation of the scene relative to the eye, into a rotation relative to the head. This suggests that transformed visual self-rotation signals may combine with vestibular signals. (2) Do transformed visual self-rotation signals reflect the arrangement of the semi-circular canals (SCC)? Previously, we found sub-regions within MST and V6+ that respond to the speed of the simulated head rotation. Here, we re-analyzed those Blood oxygenated level-dependent (BOLD) signals for the presence of a spatial dissociation related to the axes of visually simulated head rotation, such as have been found in sub-cortical regions of various animals. Contrary, we found a rather uniform BOLD response to simulated rotation along the three SCC axes. (3) We investigated if subject's sensitivity to the direction of the head rotation axis shows SCC axes specifcity. We found that sensitivity to head rotation is rather uniformly distributed, suggesting that in human cortex, visuo-vestibular integration is

  13. Visual perception of axes of head rotation

    Directory of Open Access Journals (Sweden)

    David Mattijs Arnoldussen

    2013-02-01

    Full Text Available Registration of ego-motion is important to accurately navigate through space. Movements of the head and eye relative to space are registered through the vestibular system and optical flow, respectively. Here, we address three questions concerning the visual registration of self-rotation. 1. Eye-in-head movements provide a link between the motion signals received by sensors in the moving eye and sensors in the moving head. How are these signals combined into an ego-rotation percept? We combined optic flow of simulated forward and rotational motion of the eye with different levels of eye-in-head rotation for a stationary head. We dissociated simulated gaze rotation and head rotation by different levels of eye-in-head pursuit.We found that perceived rotation matches simulated head- not gaze-rotation. This rejects a model for perceived self-rotation that relies on the rotation of the gaze line. Rather, eye-in-head signals serve to transform the optic flow’s rotation information, that specifies rotation of the scene relative to the eye, into a rotation relative to the head. This suggests that transformed visual self-rotation signals may combine with vestibular signals.2. Do transformed visual self-rotation signals reflect the arrangement of the semicircular canals (SCC? Previously, we found sub-regions within MST and V6+ that respond to the speed of the simulated head rotation. Here, we re-analyzed those BOLD signals for the presence of a spatial dissociation related to the axes of visually simulated head rotation, such as have been found in sub-cortical regions of various animals. Contrary, we found a rather uniform BOLD response to simulated rotation along the three SCC axes.3. We investigated if subject’s sensitivity to the direction of the head rotation axis shows SCC axes specifcity. We found that sensitivity to head rotation is rather uniformly distributed, suggesting that in human cortex, visuo-vestibular integration is not arranged into

  14. Public knowledge of head and neck cancer.

    LENUS (Irish Health Repository)

    O'Connor, T E

    2010-04-01

    Studies show 60% of patients with newly diagnosed Head & Neck Squamous Cell Cancer in Ireland, present with advanced disease. A poor level of knowledge and awareness among the public of Head & Neck Cancer, is an important consideration in the often delayed presentation for medical attention in many of these cases. Our study surveyed 200 members of the public to assess their knowledge and awareness of Head & Neck Cancer. One hundred and forty (70%) of respondents had never encountered the term "Head & Neck Cancer". One hundred and forty six (73%) failed to identify excessive alcohol consumption as a risk factor. Less than 100 (50%) would have concern about persisting hoarseness or a prolonged oral ulcer. An urgent need exists to raise awareness of Head & Neck Cancer among the public in Ireland.

  15. Head orientation prediction: delta quaternions versus quaternions.

    Science.gov (United States)

    Himberg, Henry; Motai, Yuichi

    2009-12-01

    Display lag in simulation environments with helmet-mounted displays causes a loss of immersion that degrades the value of virtual/augmented reality training simulators. Simulators use predictive tracking to compensate for display lag, preparing display updates based on the anticipated head motion. This paper proposes a new method for predicting head orientation using a delta quaternion (DQ)-based extended Kalman filter (EKF) and compares the performance to a quaternion EKF. The proposed framework operates on the change in quaternion between consecutive data frames (the DQ), which avoids the heavy computational burden of the quaternion motion equation. Head velocity is estimated from the DQ by an EKF and then used to predict future head orientation. We have tested the new framework with captured head motion data and compared it with the computationally expensive quaternion filter. Experimental results indicate that the proposed DQ method provides the accuracy of the quaternion method without the heavy computational burden.

  16. Gender differences in head-neck segment dynamic stabilization during head acceleration.

    Science.gov (United States)

    Tierney, Ryan T; Sitler, Michael R; Swanik, C Buz; Swanik, Kathleen A; Higgins, Michael; Torg, Joseph

    2005-02-01

    Recent epidemiological research has revealed that gender differences exist in concussion incidence but no study has investigated why females may be at greater risk of concussion. Our purpose was to determine whether gender differences existed in head-neck segment kinematic and neuromuscular control variables responses to an external force application with and without neck muscle preactivation. Forty (20 females and 20 males) physically active volunteers participated in the study. The independent variables were gender, force application (known vs unknown), and force direction (forced flexion vs forced extension). The dependent variables were kinematic and EMG variables, head-neck segment stiffness, and head-neck segment flexor and extensor isometric strength. Statistical analyses consisted of multiple multivariate and univariate analyses of variance, follow-up univariate analyses of variance, and t-tests (P Gender differences existed in head-neck segment dynamic stabilization during head angular acceleration. Females exhibited significantly greater head-neck segment peak angular acceleration (50%) and displacement (39%) than males despite initiating muscle activity significantly earlier (SCM only) and using a greater percentage of their maximum head-neck segment muscle activity (79% peak activity and 117% muscle activity area). The head-neck segment angular acceleration differences may be because females exhibited significantly less isometric strength (49%), neck girth (30%), and head mass (43%), resulting in lower levels of head-neck segment stiffness (29%). For our subject demographic, the results revealed gender differences in head-neck segment dynamic stabilization during head acceleration in response to an external force application. Females exhibited significantly greater head-neck segment peak angular acceleration and displacement than males despite initiating muscle activity earlier (SCM only) and using a greater percentage of their maximum head-neck segment

  17. Is There a Cardiotoxicity Associated With Metallic Head Hip Prostheses? A Cohort Study in the French National Health Insurance Databases.

    Science.gov (United States)

    Lassalle, Marion; Colas, Sandrine; Rudnichi, Annie; Zureik, Mahmoud; Dray-Spira, Rosemary

    2018-05-09

    There are four distinguishable types of THA devices in wide use, as defined by the femoral and acetabular bearing surfaces: metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), metal-on-metal (MoM), and ceramic-on-ceramic (CoC). Metallic head THAs (MoP and MoM) can potentially induce cardiac toxicity because cobalt species, generated at the head-neck trunnion, and in the case of MoM devices, at the articular surface as well, can be absorbed systemically. However, studies have provided inconsistent results. The purpose of this study was to assess the risk of dilated cardiomyopathy (DCM) or heart failure (HF) associated with metallic head THAs using data from the French national health insurance databases. Between 2008 and 2011 in France, 399,968 patients ≥ 55 years had a first THA. A total of 127,481 were excluded after we applied the exclusion criteria regarding arthroplasty and 17,137 as a result of a history of DCM/HF, recorded in the French national health insurance reimbursement databases, between January 1, 2006, and the date of inclusion. The final cohort included 255,350 individuals (43% men; mean age 72 ± 9 years). Of them, 93,581 (37%) had been implanted with MoP, 58,095 (23%) with CoP, 11,298 (4%) with MoM, and 92,376 (36%) with CoC THAs. Patients were followed until December 2015. Patients with incident DCM/HF were identified by a new entitlement to the long-term disease scheme or a first hospitalization with a diagnosis of DCM or HF. MoP and CoP THAs are generally implanted in old patients, whereas MoM and CoC are mostly indicated in young, active male patients. Thus, to consider the specific indications of the bearing couples, analyses were separately performed in two distinct subcohorts, one comprising patients with MoP or CoP and one comprising patients with MoM or CoC THA. In each subcohort, the DCM/HF risk was compared between patients with metallic head versus nonmetallic head THAs (MoP versus CoP, MoM versus CoC). Hazard ratios

  18. [Case of exploding head syndrome].

    Science.gov (United States)

    Okura, Mutsumi; Taniguchi, Mitsutaka; Muraki, Hisae; Sugita, Hideko; Ohi, Motoharu

    2010-01-01

    Exploding head syndrome (EHS) attacks are characterized by the sensation of sudden loud banging noises, and are occasionally accompanied by the sensation of a flash light. Although these attacks in themselves are usually not painful, it is reported that EHS attacks may precede migraines and may be perceived as auras. A 53-year-old woman, with a 40-year history of fulgurating migraines, experienced 2 different types of EHS attacks. During most of the attacks, which were not painful, she heard sounds like someone yelling or cars passing by. Only 1 episode was accompanied with the sensation of a flash light and of sounds similar to those of an electrical short circuit. On the video-polysomnography, video-polysomnography showed 11 EHS attacks occurred during stage N1 and stage N2; these attacks were preceded by soft snoring. She also had moderate obstructive sleep apnea syndrome (Apnea Hypopnea Index: 16.7) for which an oral appliance was prescribed; the EHS attacks did not recur after this treatment. The pathophysiology of EHS is still unclear. A detailed analysis of PSG data may help in understanding the pathophysiology of this syndrome and also in the selection of therapeutic strategies.

  19. "Stuttering" after minor head trauma.

    Science.gov (United States)

    Strasberg, Stephen; Johnson, Elizabeth J; Parry, Thomas

    2016-03-01

    Traumatic brain injury (TBI) is defined as impairment in brain function as a result of mechanical force. It is classified based on clinical findings using the Glasgow Coma Scale (GCS). Mild TBI is defined as GCS 14-15; moderate, 9-13; and severe, 3-8. Patients with the same TBI classification may have very different underlying pathology. In moderate to severe TBI, the primary pathology may include contusions, hemorrhage, diffuse axonal injury, direct cellular damage, "tearing and shearing of the tissues, loss of the blood-brain barrier, disruption of the neurochemical homeostasis and loss of the electrochemical function". Although the primary pathology associated with mild TBI may be milder versions of the same pathology associated with moderate and severe TBI, it is generally a metabolic injury. However, it is reported that 15% of patients with mild TBI and a GCS score of 14 or 15 will have an intracranial lesion; less than 1% of these require neurosurgical intervention. Although patients with mild TBI may have intracranial lesions, it is rare that the presenting and only physical examination finding is an isolated neurologic finding. Here we present a case of isolated head trauma with a single physical examination finding--expressive aphasia.

  20. [Head and neck adaptive radiotherapy].

    Science.gov (United States)

    Graff, P; Huger, S; Kirby, N; Pouliot, J

    2013-10-01

    Onboard volumetric imaging systems can provide accurate data of the patient's anatomy during a course of head and neck radiotherapy making it possible to assess the actual delivered dose and to evaluate the dosimetric impact of complex daily positioning variations and gradual anatomic changes such as geometric variations of tumors and normal tissues or shrinkage of external contours. Adaptive radiotherapy is defined as the correction of a patient's treatment planning to adapt for individual variations observed during treatment. Strategies are developed to selectively identify patients that require replanning because of an intolerable dosimetric drift. Automated tools are designed to limit time consumption. Deformable image registration algorithms are the cornerstones of these strategies, but a better understanding of their limits of validity is required before adaptive radiotherapy can be safely introduced to daily practice. Moreover, strict evaluation of the clinical benefits is yet to be proven. Copyright © 2013 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  1. Head circumference in Iranian infants

    Directory of Open Access Journals (Sweden)

    Mohammad Esmaeili

    2015-03-01

    Full Text Available Introduction: Head circumference (HC measurement is one of the important parameter for diagnosis of neurological, developmental disorders and dysmorphic syndromes. Recognition of different disorders requires an understanding of normal variation for HC size, in particular, in infancy period with most rapid growth of the brain. Because of international and interracial standard chart differences about anthropometric indices, some differences from local to local, generation to generation and changes in ethnic mix of population and socioeconomic factors, periodic revolution of HC size is suggested. The aims of our study were presenting local HC standard for an Iranian infant population and comparison with the American national center of health statistics (NCHS charts accepted by WHO. Methods: 1003 subjects aged from birth to 24 months apparently healthy normal children enrolled randomly in this cross sectional study. HC size were measured and recorded. Tables and graphs were depicted by Excel Microsoft Office 2007. We use two tailed t-student test for statistical analysis. Results: The mean of HC size in boys was larger than girls. The curves were followed a similar pattern to NCHS based on a visual comparison. Overall our subjects in both sexes at birth time had smaller HC size than NCHS. In other ages our children had larger HC size than those of NCHS. Conclusion: Because of international and interracial difference of HC size. We recommend in each area of the world, local anthropometric indices are constructed and used clinically. In addition more extensive and longitudinally design comprehensive studies is suggested.

  2. Optimised intake stroke analysis for flat and dome head pistons ...

    African Journals Online (AJOL)

    Optimised intake stroke analysis for flat and dome head pistons. ... in understanding the performance characteristics optioned between flat head and dome head pistons in engine design. ... EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  3. Unilateral otolith centrifugation by head tilt.

    Science.gov (United States)

    Winters, Stephanie M; Bos, Jelte E; Klis, Sjaak F L

    2014-01-01

    To test for otolith asymmetries, several studies described horizontal translation of the body and head en bloc during fast vertical axis rotation. This stimulus causes one otolithic organ to rotate on-axis, and the other to experience centripetal acceleration. To test a new, more simple method of unilateral stimulation with head tilt and the body remaining on axis. During stationary and during 360 deg/s rotation, 12 healthy blindfolded subjects had their heads tilted 30 degrees sideways, positioning one otolithic organ on the axis of rotation after the other. The haptic subjective vertical (SV) was recorded several times by means of a manually adjustable rod. It was found that during stationary the SV tilted about 4 degrees on average in the direction of the head. During rotation, the SV tilted about 9 degrees on average. We therefore estimate the effect of eccentric otolith rotation to be 5 degrees on average. Tilt of the subjective vertical induced by head tilt during on-axis body rotation can provide a relatively uncomplicated alternative to test unilateral otolithic function as compared to body and head translation during rotation. Moreover, unlike eccentric rotation of the entire body, somatosensory cues are minimized by keeping the body fixed on axis and by subtracting the effect of head tilt per se.

  4. Multi-headed comparatives in Portuguese

    Directory of Open Access Journals (Sweden)

    Rui Marques

    2005-06-01

    Full Text Available This paper aims at offering a global picture of the subtype of comparative constructions known as ‘multi-headed comparatives’ (from the fact that they exhibit more than one comparative operator in semantic interdependence. As a prerequisite to the fulfilment of his goal, an attempt will be made to clarify the scope of the notion ‘comparative construction’ and to draw a general typology of such constructions. The boundaries of the notion ‘comparative construction’ are defined by contrasting a “genuine” class of comparative constructions with others that hold some syntactic or semantic resemblance to them. Different typologies will be taken into consideration. As for multi-headed comparatives, even though different examples of these constructions have been identified in the scarce literature on the matter, the discussion on their syntactic patterns and meaning is still embryonic. This paper suggests that the expressive power of these comparatives, which seem to provide a particular strategy of information compression, is higher than has been assumed. Four sub-kinds of multi-headed comparatives are identified, based on meaning differences, namely: multi-headed comparatives with a distributive reading, multi-headed comparatives with a cumulative reading, multi-headed comparatives with a comparison of ‘ratios’ reading, and multi-headed comparatives with a comparison of differences reading. While resorting to some classic English examples, the object language will predominantly be Portuguese.

  5. Subchondral insufficiency fractures of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Davies, M.; Cassar-Pullicino, V.N. [Department of Radiology, Robert Jones and Agnes Hunt Orthopaedic and District Hospital, Oswestry, SY10 7AG, Shropshire (United Kingdom); Darby, A.J. [Department of Pathology, Robert Jones and Agnes Hunt Orthopaedic and District Hospital, Oswestry, SY10 7AG, Shropshire (United Kingdom)

    2004-02-01

    The aim of this study was to increase awareness of, and to show the variable clinical and radiological features of, subchondral insufficiency fractures of the femoral head. The clinical and radiological findings in 7 patients with subchondral insufficiency fractures of the femoral head were reviewed retrospectively. The diagnosis was confirmed histologically in 4 patients. Radiographs were performed in all patients, MRI in 5 and scintigraphy in 4 patients. Radiographs showed varying degrees of femoral head collapse in 4 patients. In the remaining 3 patients radiographs showed a normal femoral head, regional osteoporosis and focal sclerosis, respectively. Magnetic resonance imaging showed a low-signal band on T1- and T2-weighted images in the subchondral bone adjacent or parallel to the articular surface associated with bone marrow oedema. Scintigraphy showed increased uptake in the femoral head. Insufficiency fractures of the femoral head are easily overlooked or confused with avascular necrosis and, when there is significant joint destruction, osteoarthritis. Unsuspected insufficiency fracture of the femoral head can lead to significant and rapid loss of bone stock in osteoporotic patients waiting for arthroplasty for osteoarthritis. Increased awareness of this condition will hopefully lead to earlier diagnosis and a successful outcome of conservative treatment. (orig.)

  6. Head flexion angle while using a smartphone.

    Science.gov (United States)

    Lee, Sojeong; Kang, Hwayeong; Shin, Gwanseob

    2015-01-01

    Repetitive or prolonged head flexion posture while using a smartphone is known as one of risk factors for pain symptoms in the neck. To quantitatively assess the amount and range of head flexion of smartphone users, head forward flexion angle was measured from 18 participants when they were conducing three common smartphone tasks (text messaging, web browsing, video watching) while sitting and standing in a laboratory setting. It was found that participants maintained head flexion of 33-45° (50th percentile angle) from vertical when using the smartphone. The head flexion angle was significantly larger (p smartphone, could be a main contributing factor to the occurrence of neck pain of heavy smartphone users. Practitioner Summary: In this laboratory study, the severity of head flexion of smartphone users was quantitatively evaluated when conducting text messaging, web browsing and video watching while sitting and standing. Study results indicate that text messaging while sitting caused the largest head flexion than that of other task conditions.

  7. [Natural head position's reproducibility on photographs].

    Science.gov (United States)

    Eddo, Marie-Line; El Hayeck, Émilie; Hoyeck, Maha; Khoury, Élie; Ghoubril, Joseph

    2017-12-01

    The purpose of this study is to evaluate the reproducibility of natural head position with time on profile photographs. Our sample is composed of 96 students (20-30 years old) at the department of dentistry of Saint Joseph University in Beirut. Two profile photographs were taken in natural head position about a week apart. No significant differences were found between T0 and T1 (E = 1.065°). Many studies confirmed this reproducibility with time. Natural head position can be adopted as an orientation for profile photographs in orthodontics. © EDP Sciences, SFODF, 2017.

  8. TMI-2 reactor vessel head removal

    International Nuclear Information System (INIS)

    Bengel, P.R.; Smith, M.D.; Estabrook, G.A.

    1984-12-01

    This report describes the safe removal and storage of the Three Mile Island Unit 2 reactor vessel head. The head was removed in July 1984 to permit the removal of the plenum and the reactor core, which were damaged during the 1979 accident. From July 1982, plans and preparations were made using a standard head removal procedure modified by the necessary precautions and changes to account for conditions caused by the accident. After data acquisition, equipment and structure modifications, and training the head was safely removed and stored and the internals indexing fixture and a work platform were installed on top of the vessel. Dose rates during and after the operation were lower than expected; lessons were learned from the operation which will be applied to the continuing fuel removal operations activities

  9. Engineering science and mechanics department head named

    OpenAIRE

    Nystrom, Lynn A.

    2004-01-01

    Ishwar K. Puri, professor of mechanical engineering and executive associate dean of engineering at the University of Illinois at Chicago, will become the head of Virginia Tech•À_ó»s Department of Engineering Science and Mechanics Aug. 1.

  10. "Head õhtut ja õnn kaasa" / Triin Thalheim

    Index Scriptorium Estoniae

    Thalheim, Triin, 1982-

    2006-01-01

    George Clooney mängufilm "Head õhtut ja õnn kaasa" ("Good Night, and Good Luck") teleajakirjanik Edward R. Murrow võitlusest senaator Joseph McCarthy vastu. Lisatud "Filmi ajaloolised võtmetegelased"

  11. Head Lice: Malathion Frequently Asked Questions

    Science.gov (United States)

    ... be checked for signs of infestation. Does malathion kill head lice eggs? Yes. The malathion lotion (Ovide*) ... Privacy FOIA No Fear Act OIG 1600 Clifton Road Atlanta , GA 30329-4027 USA 800-CDC-INFO ( ...

  12. Drugs Approved for Head and Neck Cancer

    Science.gov (United States)

    This page lists cancer drugs approved by the Food and Drug Administration (FDA) for head and neck cancer. The list includes generic names and brand names. The drug names link to NCI’s Cancer Drug Information summaries.

  13. Heidbreder to head Office of Legal Counsel

    OpenAIRE

    Hincker, Lawrence

    2006-01-01

    Kay Heidbreder of Blacksburg, has been appointed University Counsel by the Virginia Attorney General and will head the university's legal office. Heidbreder, who holds the position of assistant attorney general, has been associate general counsel at Virginia Tech since 1985.

  14. TMI-2 reactor vessel head removal

    International Nuclear Information System (INIS)

    Bengel, P.R.; Smith, M.D.; Estabrook, G.A.

    1985-09-01

    This report describes the safe removal and storage of the Three Mile Island Unit 2 (TMI-2) reactor vessel head. The head was removed in July 1984 to permit the removal of the plenum and the reactor core, which were damaged during the 1979 accident. From July 1982, plans and preparations were made using a standard head removal procedure modified by the necessary precautions and changes to account for conditions caused by the accident. After data acquisition, equipment and structure modifications, and training, the head was safely removed and stored; and the internals indexing fixture and a work platform were installed on top of the vessel. Dose rates during and after the operation were lower than expected; lessons were learned from the operation which will be applied to the continuing fuel removal operations activities

  15. Achieving Consensus Through Professionalized Head Nods

    DEFF Research Database (Denmark)

    Oshima, Sae

    2014-01-01

    of nodding in a particular professional-client setting, namely, hair salon interactions. My interest specifically lies in the frequent occurrence of synchronized head nods during the “service-assessment sequence,” where both service provider and customer inspect and determine whether the completed work...... is adequate. I pursue mechanisms of synchronized head nods by revealing exactly how participants collaborate in producing a nod, and how their verbal actions may at times be designed accordingly. In doing so, the study provides insight into what consensus may look like at service encounters in Japan......While the interactional functions of head nodding in everyday Japanese conversation have been frequently studied, a discourse on head nodding as a professional communicative practice has yet to be explored. With the method of multimodal conversation analysis, the current study examines the role...

  16. Transfer Pricing; Charging of head office costs

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, Joergen

    1998-07-01

    The key issues discussed in this presentation are (1) What are head office costs?, (2) Why is the charging an area of concern for international companies?, (3) Which part of head office costs should be charged?, (4) OECD guidelines on charging. Head office costs are classified as Shareholder costs, Stewardship costs, Costs related to a specific subsidiary or group of subsidiaries (on call), and Costs related to operational activities in the parent company. The OECD reports of 1984 and 1996 are discussed. In Norsk Hydro's experience, the practising of the OECD guidelines by national authorities are confusing and not consistent over time or across borders. To get a better understanding of how charging of corporate head office costs are dealt with on an international level, Norsk Hydro asked Deloitte and Touche in London to carry out a study on international companies' behaviour. Their conclusions are included.

  17. Unusual Cancers of the Head and Neck

    Science.gov (United States)

    ... more information). Unusual Cancers of the Head and Neck Nasopharyngeal Cancer See the PDQ summary on Childhood ... of PDQ documents can be used freely as text. It cannot be identified as an NCI PDQ ...

  18. SEX DETERMINATION FROM FEMORAL HEAD DIAMETERS IN ...

    African Journals Online (AJOL)

    hi-tech

    2000-03-01

    Mar 1, 2000 ... In medico-legal cases where sophisticated methods of sex determination is lacking, these ... scientific methods(3). Using the visual method ... between the sexes and the values of the right and left femoral head diameters.

  19. Exploding Head Syndrome: A Case Report

    OpenAIRE

    Ganguly, Gautam; Mridha, Banshari; Khan, Asif; Rison, Richard Alan

    2013-01-01

    Introduction: Exploding head syndrome (EHS) is a rare parasomnia in which affected individuals awaken from sleep with the sensation of a loud bang. The etiology is unknown, but other conditions including primary and secondary headache disorders and nocturnal seizures need to be excluded. Case Presentation: A 57-year-old Indian male presented with four separate episodes of awakening from sleep at night after hearing a flashing sound on the right side of his head over the last 2 years. These ev...

  20. Radiographic examination of the equine head

    International Nuclear Information System (INIS)

    Park, R.D.

    1993-01-01

    Radiographic examinations of the equine head can be performed with portable x-ray machines. The views comprising the examination depend on the area of the head being examined. With a knowledge of radiographic anatomy and radiographic signs of disease, valuable diagnostic information can be obtained from the radiographic examination. In addition, the radiographic information can also be used to develop a prognosis and determine the most appropriate therapy

  1. Head Impact Biomechanics in Women's College Soccer.

    Science.gov (United States)

    Lynall, Robert C; Clark, Michael D; Grand, Erin E; Stucker, Jaclyn C; Littleton, Ashley C; Aguilar, Alain J; Petschauer, Meredith A; Teel, Elizabeth F; Mihalik, Jason P

    2016-09-01

    There are limited nonlaboratory soccer head impact biomechanics data. This is surprising given soccer's global popularity. Epidemiological data suggest that female college soccer players are at a greater concussion injury risk than their male counterparts. Therefore, the purposes of our study were to quantify head impact frequency and magnitude during women's soccer practices and games in the National Collegiate Athletic Association and to characterize these data across event type, playing position, year on the team, and segment of game (first and second halves). Head impact biomechanics were collected from female college soccer players (n = 22; mean ± SD age = 19.1 ± 0.1 yr, height = 168.0 ± 3.5 cm, mass = 63.7 ± 6.0 kg). We employed a helmetless head impact measurement device (X2 Biosystems xPatch) before each competition and practice across a single season. Peak linear and rotational accelerations were categorized based on impact magnitude and subsequently analyzed using appropriate nonparametric analyses. Overall, women's college soccer players experience approximately seven impacts per 90 min of game play. The overwhelming majority (~90%) of all head impacts were categorized into our mildest linear acceleration impact classification (10g-20g). Interestingly, a higher percentage of practice impacts in the 20g-40g range compared with games (11% vs 7%) was observed. Head impact biomechanics studies have provided valuable insights into understanding collision sports and for informing evidence-based rule and policy changes. These have included changing the football kickoff, ice hockey body checking ages, and head-to-head hits in both sports. Given soccer's global popularity, and the growing public concern for the potential long-term neurological implications of collision and contact sports, studying soccer has the potential to impact many athletes and the sports medicine professionals caring for them.

  2. Schwannomas of the head and neck

    Directory of Open Access Journals (Sweden)

    Anastasios Kanatas

    2011-12-01

    Full Text Available Schwannomas are benign encapsulated nerve sheath tumors composed of Schwann cells. Malignant change in head and neck schwannomas is rare, with the incidence varying between 8 and 13.9%. In this review, we discuss the presentation and the management of head and neck schwannomas. The issues and difficulties based on our own experience as well as the experience of published reports from the literature are presented.

  3. CAD for cutting head exchange of roadheader

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Z.; Wu, Z.; Qian, P. [China Coal Research Institute (China). Shanghai Branch

    1999-08-01

    Improving the cutting method according to the actual operating conditions is an effective way to raise production efficiency. A cutting head designed by means of computer and CAD software is characterized by short design cycle but high design quality. Taking the AM-50 road header as an example, this paper shows that it is feasible to design an interchangeable cutting head for the machine without interfering with the main technical parameters. 2 refs., 5 figs., 1 tab.

  4. Head trauma in female professional wrestlers

    International Nuclear Information System (INIS)

    Nomoto, Jun; Seiki, Yoshikatsu; Nemoto, Masaaki

    2007-01-01

    The clinical characteristics of head trauma were evaluated in 18 wrestlers belonging to a female professional wrestling organization, 13 regular members and five trainees aged 15-34 years. Medical examinations for head trauma were performed in all wrestlers, and wrestlers treated at our emergency outpatient department were clinically evaluated. In addition, the relationships of head trauma with duration of the wrestling career of 1-16 years (mean 8 years) in the regular members, and less than 1 year in the five trainees, and body mass index (BMI) of 21.0-32.0 in the 16 subjects, excluding two trainees, was evaluated. Chronic symptoms were noted in four of the 18 wrestlers with long wrestling careers (16 years in 1, 13 years in 1, and 5 years in 2). Three wrestlers with symptoms immediately after head trauma showed recurrent retrograde amnesia and had low BMI (21.6, 21.6, and 23.1). Five wrestlers were treated at our emergency outpatient clinic, three required hospitalization and two showed intracranial traumatic changes on computed tomography (acute subdural hematoma in 1 and diffuse brain swelling in 1). Head trauma in female professional wrestlers is associated with longer wrestling career and low BMI. Periodic medical examinations are recommended to monitor for signs of head trauma. (author)

  5. Non-invasive head fixation for external irradiation of tumors of the head and neck

    International Nuclear Information System (INIS)

    Bale, R.J.; Sweeney, R.; Nevinny, M.; Auer, T.; Bluhm, A.; Lukas, P.; Vogele, M.; Thumfart, W.F.

    1998-01-01

    Purpose: To fully utilize the technical capabilities of radiation diagnostics and planning, a precise and reproducible method of head fixation is a prerequisite. Method: We have adapted the Vogele-Bale-Hohner (VBH) head holder (Wellhoefer Dosimetrie, Schwarzenbruck, Germany), originally designed for frameless stereotactic operations, to the requirements of external beam radiotherapy. A precise and reproducible head fixation is attained by an individualized vacuum upper-dental cast which is connected over 2 hydraulic arms to an adjustable head- and rigid base-plate. Radiation field and patient alignment lasers are marked on a relocatable clear PVC localization box. Results: The possibility of craniocaudal adjustment of the head plate on the base plate allows the system to adapt to the actucal position of the patient on the raditherapy couch granting tensionless repositioning. The VBH head holder has proven itself to be a precise yet practicable method of head fixation. Duration of mouthpiece production and daily repositioning is comparable to that of the thermoplastic mask. Conclusion: The new head holder is in routine use at our hospital and quite suitable for external beam radiation of patients with tumors of the head and neck. (orig.) [de

  6. What are Head Cavities? - A History of Studies on Vertebrate Head Segmentation.

    Science.gov (United States)

    Kuratani, Shigeru; Adachi, Noritaka

    2016-06-01

    Motivated by the discovery of segmental epithelial coeloms, or "head cavities," in elasmobranch embryos toward the end of the 19th century, the debate over the presence of mesodermal segments in the vertebrate head became a central problem in comparative embryology. The classical segmental view assumed only one type of metamerism in the vertebrate head, in which each metamere was thought to contain one head somite and one pharyngeal arch, innervated by a set of cranial nerves serially homologous to dorsal and ventral roots of spinal nerves. The non-segmental view, on the other hand, rejected the somite-like properties of head cavities. A series of small mesodermal cysts in early Torpedo embryos, which were thought to represent true somite homologs, provided a third possible view on the nature of the vertebrate head. Recent molecular developmental data have shed new light on the vertebrate head problem, explaining that head mesoderm evolved, not by the modification of rostral somites of an amphioxus-like ancestor, but through the polarization of unspecified paraxial mesoderm into head mesoderm anteriorly and trunk somites posteriorly.

  7. Heading-vector navigation based on head-direction cells and path integration.

    Science.gov (United States)

    Kubie, John L; Fenton, André A

    2009-05-01

    Insect navigation is guided by heading vectors that are computed by path integration. Mammalian navigation models, on the other hand, are typically based on map-like place representations provided by hippocampal place cells. Such models compute optimal routes as a continuous series of locations that connect the current location to a goal. We propose a "heading-vector" model in which head-direction cells or their derivatives serve both as key elements in constructing the optimal route and as the straight-line guidance during route execution. The model is based on a memory structure termed the "shortcut matrix," which is constructed during the initial exploration of an environment when a set of shortcut vectors between sequential pairs of visited waypoint locations is stored. A mechanism is proposed for calculating and storing these vectors that relies on a hypothesized cell type termed an "accumulating head-direction cell." Following exploration, shortcut vectors connecting all pairs of waypoint locations are computed by vector arithmetic and stored in the shortcut matrix. On re-entry, when local view or place representations query the shortcut matrix with a current waypoint and goal, a shortcut trajectory is retrieved. Since the trajectory direction is in head-direction compass coordinates, navigation is accomplished by tracking the firing of head-direction cells that are tuned to the heading angle. Section 1 of the manuscript describes the properties of accumulating head-direction cells. It then shows how accumulating head-direction cells can store local vectors and perform vector arithmetic to perform path-integration-based homing. Section 2 describes the construction and use of the shortcut matrix for computing direct paths between any pair of locations that have been registered in the shortcut matrix. In the discussion, we analyze the advantages of heading-based navigation over map-based navigation. Finally, we survey behavioral evidence that nonhippocampal

  8. Kinematics of a Head-Neck Model Simulating Whiplash

    Science.gov (United States)

    Colicchia, Giuseppe; Zollman, Dean; Wiesner, Hartmut; Sen, Ahmet Ilhan

    2008-01-01

    A whiplash event is a relative motion between the head and torso that occurs in rear-end automobile collisions. In particular, the large inertia of the head results in a horizontal translation relative to the thorax. This paper describes a simulation of the motion of the head and neck during a rear-end (whiplash) collision. A head-neck model that…

  9. 29 CFR 1620.21 - Head of household.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 4 2010-07-01 2010-07-01 false Head of household. 1620.21 Section 1620.21 Labor Regulations Relating to Labor (Continued) EQUAL EMPLOYMENT OPPORTUNITY COMMISSION THE EQUAL PAY ACT § 1620.21 Head of household. Since a “head of household” or “head of family” status bears no relationship to the...

  10. Pocket Proteins Suppress Head and Neck Cancer

    Science.gov (United States)

    Shin, Myeong-Kyun; Pitot, Henry C.; Lambert, Paul F.

    2012-01-01

    Head and neck squamous cell carcinomas (HNSCC) is a common cancer in humans long known to be caused by tobacco and alcohol use, but now an increasing percentage of HNSCC is recognized to be caused by the same human papillomaviruses (HPVs) that cause cervical and other anogenital cancers. HPV-positive HNSCCs differ remarkably from HPV-negative HNSCCs in their clinical response and molecular properties. From studies in mice, we know that E7 is the dominant HPV oncoprotein in head and neck cancer. E7 is best known for its ability to inactivate pRb, the product of the retinoblastoma tumor susceptibility gene. However loss of pRb function does not fully account for E7’s potency in causing head and neck cancer. In this study, we characterized the cancer susceptibility of mice deficient in the expression of pRb and either of two related “pocket” proteins, p107 and p130, that are also inactivated by E7. pRb/p107 deficient mice developed head and neck cancer as frequently as do HPV16 E7 transgenic mice. The head and neck epithelia of the pRb/p107 deficient mice also displayed the same acute phenotypes and biomarker readouts as observed in the epithelia of E7 transgenic mice. Mice deficient for pRb and p130 in their head and neck epithelia showed intermediate acute and tumor phenotypes. We conclude that pRb and p107 act together to efficiently suppress head and neck cancer, and are therefore highly relevant targets of HPV16 E7 in its contribution to HPV-positive HNSCC. PMID:22237625

  11. Facial preservation following extreme mummification: Shrunken heads.

    Science.gov (United States)

    Houlton, Tobias M R; Wilkinson, Caroline

    2018-05-01

    Shrunken heads are a mummification phenomenon unique to South America. Ceremonial tsantsa are ritually reduced heads from enemy victims of the Shuar, Achuar, Awajún (Aguaruna), Wampís (Huambisa), and Candoshi-Shapra cultures. Commercial shrunken heads are comparatively modern and fraudulently produced for the curio-market, often using stolen bodies from hospital mortuaries and graves. To achieve shrinkage and desiccation, heads undergo skinning, simmering (in water) and drying. Considering the intensive treatments applied, this research aims to identify how the facial structure can alter and impact identification using post-mortem depiction. Sixty-five human shrunken heads were assessed: 6 ceremonial, 36 commercial, and 23 ambiguous. Investigations included manual inspection, multi-detector computerised tomography, infrared reflectography, ultraviolet fluorescence and microscopic hair analysis. The mummification process disfigures the outer face, cheeks, nasal root and bridge form, including brow ridge, eyes, ears, mouth, and nose projection. Melanin depletion, epidermal degeneration, and any applied staining changes the natural skin complexion. Papillary and reticular dermis separation is possible. Normal hair structure (cuticle, cortex, medulla) is retained. Hair appears longer (unless cut) and more profuse following shrinkage. Significant features retained include skin defects, facial creases, hairlines and earlobe form. Hair conditions that only affect living scalps are preserved (e.g. nits, hair casts). Ear and nose cartilage helps to retain some morphological information. Commercial heads appear less distorted than ceremonial tsantsa, often presenting a definable eyebrow shape, vermillion lip shape, lip thickness (if mouth is open), philtrum form, and palpebral slit angle. Facial identification capabilities are considered limited, and only perceived possible for commercial heads. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. The Head to Head That Had to Happen: A Case Study of Television Sport and Entrepreneurship.

    Science.gov (United States)

    Whannel, Garry

    The race between Mary Decker and Zola Budd, a head to head confrontation in the 1985 Olympic Games, is examined within the broader context of the transformation taking place in sports as a result of the combined efforts of television and the economic forces of sponsorship. Athletics is going through this process of transformation both economically…

  13. Head Rotation Detection in Marmoset Monkeys

    Science.gov (United States)

    Simhadri, Sravanthi

    Head movement is known to have the benefit of improving the accuracy of sound localization for humans and animals. Marmoset is a small bodied New World monkey species and it has become an emerging model for studying the auditory functions. This thesis aims to detect the horizontal and vertical rotation of head movement in marmoset monkeys. Experiments were conducted in a sound-attenuated acoustic chamber. Head movement of marmoset monkey was studied under various auditory and visual stimulation conditions. With increasing complexity, these conditions are (1) idle, (2) sound-alone, (3) sound and visual signals, and (4) alert signal by opening and closing of the chamber door. All of these conditions were tested with either house light on or off. Infra-red camera with a frame rate of 90 Hz was used to capture of the head movement of monkeys. To assist the signal detection, two circular markers were attached to the top of monkey head. The data analysis used an image-based marker detection scheme. Images were processed using the Computation Vision Toolbox in Matlab. The markers and their positions were detected using blob detection techniques. Based on the frame-by-frame information of marker positions, the angular position, velocity and acceleration were extracted in horizontal and vertical planes. Adaptive Otsu Thresholding, Kalman filtering and bound setting for marker properties were used to overcome a number of challenges encountered during this analysis, such as finding image segmentation threshold, continuously tracking markers during large head movement, and false alarm detection. The results show that the blob detection method together with Kalman filtering yielded better performances than other image based techniques like optical flow and SURF features .The median of the maximal head turn in the horizontal plane was in the range of 20 to 70 degrees and the median of the maximal velocity in horizontal plane was in the range of a few hundreds of degrees per

  14. Heat exchanger, head and shell acceptance criteria

    International Nuclear Information System (INIS)

    Lam, P.S.; Sindelar, R.L.

    1992-09-01

    Instability of postulated flaws in the head component of the heat exchanger could not produce a large break, equivalent to a DEGB in the PWS piping, due to the configuration of the head and restraint provided by the staybolts. Rather, leakage from throughwall flaws in the head would increase with flaw length with finite leakage areas that are bounded by a post-instability flaw configuration. Postulated flaws at instability in the shell of the heat exchanger or in the cooling water nozzles could produce a large break in the Cooling Water System (CWS) pressure boundary. An initial analysis of flaw stability for postulated flaws in the heat exchanger head was performed in January 1992. This present report updates that analysis and, additionally, provides acceptable flaw configurations to maintain defined structural or safety margins against flaw instability of the external pressure boundary components of the heat exchanger, namely the head, shell, and cooling water nozzles. Structural and flaw stability analyses of the heat exchanger tubes, the internal pressure boundary of the heat exchangers or interface boundary between the PWS and CWS, were previously completed in February 1992 as part of the heat exchanger restart evaluation and are not covered in this report

  15. Avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Kokubo, Takeshi; Takatori, Yoshio; Kamogawa, Morihide; Nakamura, Toshitaka; Ninomiya, Setsuo; Yoshikawa, Kohki; Itai, Yuji; Iio, Masahiro; Mitamura, Tadayuki

    1990-01-01

    T1-weighted MR images of thirty-six hips in 25 patients with avascular necrosis of the femoral head were obtained two to five times during the course of 2 to 26 months. We investigated these MR images in the light of the chronological change and compared them with plain radiographs. MR images changes in 16 femoral head; in general, the abnormal low intensity area in the femoral head reduced in extent and the internal high intensity area became smaller of disappeared. Thirteen femoral heads among them became more flattened on plain radiographs in the same period. It is noted that four different zones are defined in the femoral head after bone necrosis takes place: the dead bone marrow, the dead marrow which still contains fat, the reactive interface and the hyperemic bone marrow. In T1-weighted MR images, the dead bone marrow, the reactive interface and the hyperemic bone marrow are demonstrated as low intensity area, while the dead marrow containing fat may remain high in intensity. On the basis of this knowledge of histopathology and MR images of this disease, we suggest that reduction of the abnormal low intensity area and disappearance of the internal high intensity area on MR images can be regarded as diminution of hyperemia in the living bone marrow and loss of fat in the dead bone marrow, respectively. (author)

  16. Uncertainties in effective dose estimates of adult CT head scans: The effect of head size

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Bibbo, Giovanni; Pattison, John E.

    2009-01-01

    Purpose: This study is an extension of a previous study where the uncertainties in effective dose estimates from adult CT head scans were calculated using four CT effective dose estimation methods, three of which were computer programs (CT-EXPO, CTDOSIMETRY, and IMPACTDOSE) and one that involved the dose length product (DLP). However, that study did not include the uncertainty contribution due to variations in head sizes. Methods: The uncertainties due to head size variations were estimated by first using the computer program data to calculate doses to small and large heads. These doses were then compared with doses calculated for the phantom heads used by the computer programs. An uncertainty was then assigned based on the difference between the small and large head doses and the doses of the phantom heads. Results: The uncertainties due to head size variations alone were found to be between 4% and 26% depending on the method used and the patient gender. When these uncertainties were included with the results of the previous study, the overall uncertainties in effective dose estimates (stated at the 95% confidence interval) were 20%-31% (CT-EXPO), 15%-30% (CTDOSIMETRY), 20%-36% (IMPACTDOSE), and 31%-40% (DLP). Conclusions: For the computer programs, the lower overall uncertainties were still achieved when measured values of CT dose index were used rather than tabulated values. For DLP dose estimates, head size variations made the largest (for males) and second largest (for females) contributions to effective dose uncertainty. An improvement in the uncertainty of the DLP method dose estimates will be achieved if head size variation can be taken into account.

  17. Uncertainties in effective dose estimates of adult CT head scans: The effect of head size

    Energy Technology Data Exchange (ETDEWEB)

    Gregory, Kent J.; Bibbo, Giovanni; Pattison, John E. [Department of Medical Physics, Royal Adelaide Hospital, Adelaide, South Australia 5000 (Australia) and School of Electrical and Information Engineering (Applied Physics), University of South Australia, Mawson Lakes, South Australia 5095 (Australia); Division of Medical Imaging, Women' s and Children' s Hospital, North Adelaide, South Australia 5006 (Australia) and School of Electrical and Information Engineering (Applied Physics), University of South Australia, Mawson Lakes, South Australia 5095 (Australia); School of Electrical and Information Engineering (Applied Physics), University of South Australia, Mawson Lakes, South Australia 5095 (Australia)

    2009-09-15

    Purpose: This study is an extension of a previous study where the uncertainties in effective dose estimates from adult CT head scans were calculated using four CT effective dose estimation methods, three of which were computer programs (CT-EXPO, CTDOSIMETRY, and IMPACTDOSE) and one that involved the dose length product (DLP). However, that study did not include the uncertainty contribution due to variations in head sizes. Methods: The uncertainties due to head size variations were estimated by first using the computer program data to calculate doses to small and large heads. These doses were then compared with doses calculated for the phantom heads used by the computer programs. An uncertainty was then assigned based on the difference between the small and large head doses and the doses of the phantom heads. Results: The uncertainties due to head size variations alone were found to be between 4% and 26% depending on the method used and the patient gender. When these uncertainties were included with the results of the previous study, the overall uncertainties in effective dose estimates (stated at the 95% confidence interval) were 20%-31% (CT-EXPO), 15%-30% (CTDOSIMETRY), 20%-36% (IMPACTDOSE), and 31%-40% (DLP). Conclusions: For the computer programs, the lower overall uncertainties were still achieved when measured values of CT dose index were used rather than tabulated values. For DLP dose estimates, head size variations made the largest (for males) and second largest (for females) contributions to effective dose uncertainty. An improvement in the uncertainty of the DLP method dose estimates will be achieved if head size variation can be taken into account.

  18. Head injury: audit of a clinical guideline to justify head CT

    International Nuclear Information System (INIS)

    Haydon, Nicholas B.

    2013-01-01

    Head injury causes significant morbidity and mortality, and there is contention about which patients to scan. The UK National Health Service Clinical Guideline (CG) 56 provides criteria for selecting patients with clinically important brain injury who may benefit from a head CT scan, while minimising the radiation and economic burden of scanning patients without significant injury. This study aims to audit the documentation of the use of these guidelines in a busy UK trauma hospital and discusses the comparison with an Australian (New South Wales (NSW) ) head injury guideline. A retrospective cohort study of 480 patients presenting with head injury to the emergency department over 2 months was performed. The patient notes were assessed for documentation of each aspect of the clinical guidelines. Criteria were established to assess the utilisation of the CG 56. A database of clinical data was amalgamated with the head CT scan results for each patient. For the UK CG 56, 73% of the criteria were documented, with the least documented being 'signs of basal skull fracture' and 'amnesia of events'. Thirty-two per cent of patients received head CT and of these, 24% (37 patients) were reported to have pathology. Twenty-four patients underwent head CT without clinical justification being documented, none of which had reported pathology on CT. The study shows that the head injury guidelines are not being fully utilised at a major UK trauma hospital, resulting in 5% of patients being exposed to ionising radiation without apparent documented clinical justification. The NSW guideline has distinct differences to the CG 56, with a more complex algorithm and an absence of specific time frames for head CT completion. The results suggest a need for further education and awareness of head injury clinical guidelines.

  19. Corrado Pettenati acting head of ETT

    CERN Multimedia

    2004-01-01

    Following the departure of Juan Antonio Rubio, Corrado Pettenati has been appointed as the acting head of the ETT unit with effect from 1 August. He joined CERN in 1995 as head librarian, reorganizing and modernizing the library before becoming deputy leader of ETT from June 2000 to April 2004. Previously, he worked at the European University Institute in Florence from 1976, developing automated library systems and becoming head of the computer centre in 1985. He has also been a software analyst and a telecommunications specialist. In 2003 he was appointed as member of the steering committee of the Cellule de Coordination Documentaire Nationale pour les Mathématiques de Grenoble, and in 2004 became a member of the EULER - European Libraries and Electronic Resources in Mathematical Sciences - Scientific Advisory Board, based in Germany. He was born in 1946 and graduated with a degree in Electrical Engineering from the Polytechnic in Milan in 1969.

  20. [Diagnostic and organizational error in head injuries].

    Science.gov (United States)

    Zaba, Czesław; Zaba, Zbigniew; Swiderski, Paweł; Lorkiewicz-Muszyíska, Dorota

    2009-01-01

    The study aimed at presenting a case of a diagnostic and organizational error involving lack of detection of foreign body presence in the soft tissues of the head. Head radiograms in two projections clearly demonstrated foreign bodies that resembled in shape flattened bullets, which could not have been missed upon evaluation of the X-rays. On the other hand, description of the radiograms entered by the attending physicians to the patient's medical record indicated an absence of traumatic injuries or foreign bodies. In the opinion of the authors, the case in question involved a diagnostic error: the doctors failed to detect the presence of foreign bodies in the head. The organizational error involved the failure of radiogram evaluation performed by a radiologist.

  1. Exploding head syndrome: a case report.

    Science.gov (United States)

    Ganguly, Gautam; Mridha, Banshari; Khan, Asif; Rison, Richard Alan

    2013-01-01

    Exploding head syndrome (EHS) is a rare parasomnia in which affected individuals awaken from sleep with the sensation of a loud bang. The etiology is unknown, but other conditions including primary and secondary headache disorders and nocturnal seizures need to be excluded. A 57-year-old Indian male presented with four separate episodes of awakening from sleep at night after hearing a flashing sound on the right side of his head over the last 2 years. These events were described 'as if there are explosions in my head'. A neurologic examination, imaging studies, and a polysomnogram ensued, and the results led to the diagnosis of EHS. EHS is a benign, uncommon, predominately nocturnal disorder that is self-limited. No treatment is generally required. Reassurance to the patient is often all that is needed.

  2. The Danish Head and Neck Cancer database

    DEFF Research Database (Denmark)

    Overgaard, Jens; Jovanovic, Aleksandar; Godballe, Christian

    2016-01-01

    of continuous clinical trials and subsequent implementation in national guidelines. The database has furthermore been used to describe the effect of reduced waiting time, changed epidemiology, and influence of comorbidity and socioeconomic parameters. CONCLUSION: Half a century of registration of head and neck......AIM OF THE DATABASE: The Danish Head and Neck Cancer database is a nationwide clinical quality database that contains prospective data collected since the early 1960s. The overall aim of this study was to describe the outcome of the national strategy for multidisciplinary treatment of head and neck......) of cancer in the nasal sinuses, salivary glands, or thyroid gland (corresponding to the International Classification of Diseases, tenth revision, classifications C.01-C.11, C.30-C.32, C.73, and C.80). MAIN VARIABLES: The main variables used in the study were symptoms and the duration of the symptoms...

  3. Radiologic head CT interpretation errors in pediatric abusive and non-abusive head trauma patients

    International Nuclear Information System (INIS)

    Kralik, Stephen F.; Finke, Whitney; Wu, Isaac C.; Ho, Chang Y.; Hibbard, Roberta A.; Hicks, Ralph A.

    2017-01-01

    Pediatric head trauma, including abusive head trauma, is a significant cause of morbidity and mortality. The purpose of this research was to identify and evaluate radiologic interpretation errors of head CTs performed on abusive and non-abusive pediatric head trauma patients from a community setting referred for a secondary interpretation at a tertiary pediatric hospital. A retrospective search identified 184 patients <5 years of age with head CT for known or potential head trauma who had a primary interpretation performed at a referring community hospital by a board-certified radiologist. Two board-certified fellowship-trained neuroradiologists at an academic pediatric hospital independently interpreted the head CTs, compared their interpretations to determine inter-reader discrepancy rates, and resolved discrepancies to establish a consensus second interpretation. The primary interpretation was compared to the consensus second interpretation using the RADPEER trademark scoring system to determine the primary interpretation-second interpretation overall and major discrepancy rates. MRI and/or surgical findings were used to validate the primary interpretation or second interpretation when possible. The diagnosis of abusive head trauma was made using clinical and imaging data by a child abuse specialist to separate patients into abusive head trauma and non-abusive head trauma groups. Discrepancy rates were compared for both groups. Lastly, primary interpretations and second interpretations were evaluated for discussion of imaging findings concerning for abusive head trauma. There were statistically significant differences between primary interpretation-second interpretation versus inter-reader overall and major discrepancy rates (28% vs. 6%, P=0.0001; 16% vs. 1%, P=0.0001). There were significant differences in the primary interpretation-second interpretation overall and major discrepancy rates for abusive head trauma patients compared to non-abusive head trauma

  4. Radiologic head CT interpretation errors in pediatric abusive and non-abusive head trauma patients

    Energy Technology Data Exchange (ETDEWEB)

    Kralik, Stephen F.; Finke, Whitney; Wu, Isaac C.; Ho, Chang Y. [Indiana University School of Medicine, Department of Radiology and Imaging Sciences, Indianapolis, IN (United States); Hibbard, Roberta A.; Hicks, Ralph A. [Indiana University School of Medicine, Department of Pediatrics, Section of Child Protection Programs, Indianapolis, IN (United States)

    2017-07-15

    Pediatric head trauma, including abusive head trauma, is a significant cause of morbidity and mortality. The purpose of this research was to identify and evaluate radiologic interpretation errors of head CTs performed on abusive and non-abusive pediatric head trauma patients from a community setting referred for a secondary interpretation at a tertiary pediatric hospital. A retrospective search identified 184 patients <5 years of age with head CT for known or potential head trauma who had a primary interpretation performed at a referring community hospital by a board-certified radiologist. Two board-certified fellowship-trained neuroradiologists at an academic pediatric hospital independently interpreted the head CTs, compared their interpretations to determine inter-reader discrepancy rates, and resolved discrepancies to establish a consensus second interpretation. The primary interpretation was compared to the consensus second interpretation using the RADPEER trademark scoring system to determine the primary interpretation-second interpretation overall and major discrepancy rates. MRI and/or surgical findings were used to validate the primary interpretation or second interpretation when possible. The diagnosis of abusive head trauma was made using clinical and imaging data by a child abuse specialist to separate patients into abusive head trauma and non-abusive head trauma groups. Discrepancy rates were compared for both groups. Lastly, primary interpretations and second interpretations were evaluated for discussion of imaging findings concerning for abusive head trauma. There were statistically significant differences between primary interpretation-second interpretation versus inter-reader overall and major discrepancy rates (28% vs. 6%, P=0.0001; 16% vs. 1%, P=0.0001). There were significant differences in the primary interpretation-second interpretation overall and major discrepancy rates for abusive head trauma patients compared to non-abusive head trauma

  5. Head movements and postures as pain behavior

    Science.gov (United States)

    Al-Hamadi, Ayoub; Limbrecht-Ecklundt, Kerstin; Walter, Steffen; Traue, Harald C.

    2018-01-01

    Pain assessment can benefit from observation of pain behaviors, such as guarding or facial expression, and observational pain scales are widely used in clinical practice with nonverbal patients. However, little is known about head movements and postures in the context of pain. In this regard, we analyze videos of three publically available datasets. The BioVid dataset was recorded with healthy participants subjected to painful heat stimuli. In the BP4D dataset, healthy participants performed a cold-pressor test and several other tasks (meant to elicit emotion). The UNBC dataset videos show shoulder pain patients during range-of-motion tests to their affected and unaffected limbs. In all videos, participants were sitting in an upright position. We studied head movements and postures that occurred during the painful and control trials by measuring head orientation from video over time, followed by analyzing posture and movement summary statistics and occurrence frequencies of typical postures and movements. We found significant differences between pain and control trials with analyses of variance and binomial tests. In BioVid and BP4D, pain was accompanied by head movements and postures that tend to be oriented downwards or towards the pain site. We also found differences in movement range and speed in all three datasets. The results suggest that head movements and postures should be considered for pain assessment and research. As additional pain indicators, they possibly might improve pain management whenever behavior is assessed, especially in nonverbal individuals such as infants or patients with dementia. However, in advance more research is needed to identify specific head movements and postures in pain patients. PMID:29444153

  6. Reactor vessel closure head replacements in 1997

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    The Framatome-Jeumont Industrie consortium have completed in 1997 28 reactor vessel (RV) closure head replacements, including five on 1300 MWe class PWR units. Framatome manages the operations and handles removal and reinstallation of equipment (not including the control rod drive mechanisms (CRDM)) and the requalification tests, while JI, which manufactures the CRDMs, is involved in the CRDM cutting, re-machining and welding operations, using tools of original design, in order to optimize the RV closure head operation in terms of costs, schedule and dosage

  7. Hyperparathyroidism following head and neck irradiation

    International Nuclear Information System (INIS)

    Rao, S.D.; Frame, B.; Miller, M.J.; Kleerskoper, M.; Block, M.A.; Parfitt, A.M.

    1980-01-01

    A history of head and neck irradiation in childhood or adolescence was found in 22 of 130 patients with primary hyperparathyroidism compared with only 12 of 400 control patients. Among 200 patients with a known history of childhood irradiation, biochemical or surgical evidence of hyperparathyroidism was found in ten, a prevalence of 5%. This is at least 30 times the prevalence of hyperparathyroidism in the general population. The data indicate that head and neck irradiation should be regarded as an important risk factor in the subsequent development of hyperparathyroidism

  8. Design verification for reactor head replacement

    International Nuclear Information System (INIS)

    Dwivedy, K.K.; Whitt, M.S.; Lee, R.

    2005-01-01

    This paper outlines the challenges of design verification for reactor head replacement for PWR plants and the program for qualification from the prospective of the utility design engineering group. This paper is based on the experience with the design confirmation of four reactor head replacements for two plants, and their interfacing components, parts, appurtenances, and support structures. The reactor head replacement falls under the jurisdiction of the applicable edition of the ASME Section XI code, with particular reference to repair/replacement activities. Under any repair/replacement activities, demands may be encountered in the development of program and plan for replacement due to the vintage of the original design/construction Code and the design reports governing the component qualifications. Because of the obvious importance of the reactor vessel, these challenges take on an added significance. Additional complexities are introduced to the project, when the replacement components are fabricated by vendors different from the original vendor. Specific attention is needed with respect to compatibility with the original design and construction of the part and interfacing components. The program for reactor head replacement requires evaluation of welding procedures, applicable examination, test, and acceptance criteria for material, welds, and the components. Also, the design needs to take into consideration the life of the replacement components with respect to the extended period of operation of the plant after license renewal and other plant improvements. Thus, the verification of acceptability of reactor head replacement provides challenges for development and maintenance of a program and plan, design specification, design report, manufacturer's data report and material certification, and a report of reconciliation. The technical need may also be compounded by other challenges such as widely scattered global activities and organizational barriers, which

  9. Head first PHP and MySQL

    CERN Document Server

    Beighley, Lynn

    2008-01-01

    If you're ready to create web pages more complex than those you can build with HTML and CSS, Head First PHP & MySQL is the ultimate learning guide to building dynamic, database-driven websites using PHP and MySQL. Packed with real-world examples, this book teaches you all the essentials of server-side programming, from the fundamentals of PHP and MySQL coding to advanced topics such as form validation, session IDs, cookies, database queries and joins, file I/O operations, content management, and more. Head First PHP & MySQL offers the same visually rich format that's turned every title in th

  10. MR of head and neck hemangiomas

    International Nuclear Information System (INIS)

    Bilaniuk, L.T.; Zimmerman, R.A.; Gusnard, D.A.

    1990-01-01

    This paper defines the MR characteristics of head and neck hemangiomas and to evaluate the role of MR in their diagnosis and management. Eighteen pediatric and young adult patients with head and neck hemangiomas (six neck, six face, three eyelid, two scalp, and one parotid) underwent high-field-strength 1.5-T MR imaging. Conventional spin-echo sequences with T1 and T2 weighting were performed. In addition, one-third of patients underwent MR angiography and gadolinium enhancement. The hemangiomas were isointense to muscle on T1-weighted images and hyperintense on proton-density and T2-weighted images

  11. Hyperparathyroidism following head and neck irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Rao, S.D.; Frame, B.; Miller, M.J.; Kleerskoper, M.; Block, M.A.; Parfitt, A.M.

    1980-02-01

    A history of head and neck irradiation in childhood or adolescence was found in 22 of 130 patients with primary hyperparathyroidism compared with only 12 of 400 control patients. Among 200 patients with a known history of childhood irradiation, biochemical or surgical evidence of hyperparathyroidism was found in ten, a prevalence of 5%. This is at least 30 times the prevalence of hyperparathyroidism in the general population. The data indicate that head and neck irradiation should be regarded as an important risk factor in the subsequent development of hyperparathyroidism.

  12. Head Trauma in Mixed Martial Arts.

    Science.gov (United States)

    Hutchison, Michael G; Lawrence, David W; Cusimano, Michael D; Schweizer, Tom A

    2014-06-01

    Mixed martial arts (MMA) is a full combative sport with a recent global increase in popularity despite significant scrutiny from medical associations. To date, the empirical research of the risk of head injuries associated with this sport is limited. Youth and amateur participation is growing, warranting investigation into the burden and mechanism of injuries associated with this sport. (1) To determine the incidence, risk factors, and characteristics of knockouts (KOs) and technical knockouts (TKOs) from repetitive strikes in professional MMA; and (2) to identify the mechanisms of head trauma and the situational factors that lead to KOs and TKOs secondary to repetitive strikes through video analysis. Descriptive epidemiology study. Competition data and video records for all KOs and TKOs from numbered Ultimate Fighting Championship MMA events (n = 844) between 2006 to 2012. Analyses included (1) multivariate logistic regression to investigate factors associated with an increased risk of sustaining a KO or TKO secondary to repetitive strikes and (2) video analysis of all KOs and TKOs secondary to repetitive strikes with descriptive statistics. During the study period, the KO rate was 6.4 per 100 athlete-exposures (AEs) (12.7% of matches), and the rate of TKOs secondary to repetitive strikes was 9.5 per 100 AEs (19.1% of matches), for a combined incidence of match-ending head trauma of 15.9 per 100 AEs (31.9% of matches). Logistic regression identified that weight class, earlier time in a round, earlier round in a match, and older age were risk factors for both KOs and TKOs secondary to repetitive strikes. Match significance and previously sustained KOs or TKOs were also risk factors for KOs. Video analysis identified that all KOs were the result of direct impact to the head, most frequently a strike to the mandibular region (53.9%). The average time between the KO-strike and match stoppage was 3.5 seconds (range, 0-20 seconds), with losers sustaining an average of 2

  13. Neuroimaging differential diagnoses to abusive head trauma

    International Nuclear Information System (INIS)

    Girard, Nadine; Brunel, Herve; Dory-Lautrec, Philippe; Chabrol, Brigitte

    2016-01-01

    Trauma is the most common cause of death in childhood, and abusive head trauma is the most common cause of traumatic death and morbidity in infants younger than 1 year. The main differential diagnosis of abusive head trauma is accidental traumatic brain injury, which is usually witnessed. This paper also discusses more uncommon diagnoses such as congenital and acquired disorders of hemostasis, cerebral arteriovenous malformations and metabolic diseases, all of which are extremely rare. Diagnostic imaging including CT and MRI is very important for the distinction of non-accidental from accidental traumatic injury. (orig.)

  14. Neuroimaging differential diagnoses to abusive head trauma

    Energy Technology Data Exchange (ETDEWEB)

    Girard, Nadine [AP-HM Timone 2, Department of Neuroradiology, Marseille cedex 05 (France); Aix Marseille University, UMR CNRS 7339, Marseille (France); Brunel, Herve; Dory-Lautrec, Philippe [AP-HM Timone 2, Department of Neuroradiology, Marseille cedex 05 (France); Chabrol, Brigitte [AP-HM Timone, Department of Pediatric Neurology, Marseille (France)

    2016-05-15

    Trauma is the most common cause of death in childhood, and abusive head trauma is the most common cause of traumatic death and morbidity in infants younger than 1 year. The main differential diagnosis of abusive head trauma is accidental traumatic brain injury, which is usually witnessed. This paper also discusses more uncommon diagnoses such as congenital and acquired disorders of hemostasis, cerebral arteriovenous malformations and metabolic diseases, all of which are extremely rare. Diagnostic imaging including CT and MRI is very important for the distinction of non-accidental from accidental traumatic injury. (orig.)

  15. Head injury and risk for Parkinson disease

    DEFF Research Database (Denmark)

    Kenborg, Line; Rugbjerg, Kathrine; Lee, Pei-Chen

    2015-01-01

    in medical records. Patients were matched to 1,785 controls randomly selected from the Danish Central Population Register on sex and year of birth. Odds ratios (ORs) and 95% confidence intervals (CIs) were estimated using unconditional logistic regression. RESULTS: We observed no association between any head......OBJECTIVE: To examine the association between head injuries throughout life and the risk for Parkinson disease (PD) in an interview-based case-control study. METHODS: We identified 1,705 patients diagnosed with PD at 10 neurologic centers in Denmark in 1996-2009 and verified their diagnoses...

  16. Hydro-thermal power flow scheduling accounting for head variations

    International Nuclear Information System (INIS)

    El-Hawary, M.E.; Ravindranath, K.M.

    1992-01-01

    In this paper the authors treat the problem of optimal economic operation of hydrothermal electric power systems with variable head hydro plants employing the power flow equations to represent the network. Newton's method is used to solve the problem for a number of test systems. A comparison with solutions with fixed head is presented. In general the optimal schedule requires higher slack bus and thermal power generation and cost in the case of variable head hydro plant than that required by the fixed head hydro plant in all demand periods. Correspondingly, the hydro generation is less in the case of variable head hydro plant compared to fixed head hydro plant. A negligible difference in voltage magnitudes in all the time intervals, but it is observed that slightly higher voltages occur in the case of the fixed head hydro plant. Higher power and energy losses occur in the case of variable head hydro plants compared to the fixed head hydro plants

  17. Effect of head restraint backset on head-neck kinematics in whiplash.

    Science.gov (United States)

    Stemper, Brian D; Yoganandan, Narayan; Pintar, Frank A

    2006-03-01

    Although head restraints were introduced in the 1960s as a countermeasure for whiplash, their limited effectiveness has been attributed to incorrect positioning. The effect of backset on cervical segmental angulations, which were previously correlated with spinal injury, has not been delineated. Therefore, the practical restraint position to minimize injury remains unclear. A parametric study of increasing head restraint backset between 0 and 140mm was conducted using a comprehensively validated computational model. Head retraction values increased with increasing backset, reaching a maximum value of 53.5mm for backsets greater than 60mm. Segmental angulation magnitudes, greatest at levels C5-C6 and C6-C7, reached maximum values during the retraction phase and increased with increasing backset. Results were compared to a previously published head restraint rating system, wherein lower cervical extension magnitudes from this study exceeded mean physiologic limits for restraint positions rated good, acceptable, marginal, and poor. As head restraint contact was the limiting factor in head retraction and segmental angulations, the present study indicates that minimizing whiplash injury may be accomplished by limiting head restraint backset to less than 60mm either passively or actively after impact.

  18. Data For: Heading Through A Crowd

    OpenAIRE

    Riddell, Hugh; Lappe, Markus

    2018-01-01

    Data and analysis scripts to accompany the article "Heading Through A Crowd" by Dr. Hugh Riddell and Prof. Dr. Markus Lappe. All analysis scripts are in SPSS format. Data has been provided in SPSS and .txt formats. Any correspondence should be addressed to Prof. Dr. Markus Lappe.

  19. Speaker Prediction based on Head Orientations

    NARCIS (Netherlands)

    Rienks, R.J.; Poppe, Ronald Walter; van Otterlo, M.; Poel, Mannes; Poel, M.; Nijholt, A.; Nijholt, Antinus

    2005-01-01

    To gain insight into gaze behavior in meetings, this paper compares the results from a Naive Bayes classifier, Neural Networks and humans on speaker prediction in four-person meetings given solely the azimuth head angles. The Naive Bayes classifier scored 69.4% correctly, Neural Networks 62.3% and

  20. Management of common head and neck masses.

    Science.gov (United States)

    Tracy, Thomas F; Muratore, Christopher S

    2007-02-01

    Head and neck masses are a common clinical concern in infants, children, and adolescents. The differential diagnosis for a head or neck mass includes congenital, inflammatory, and neoplastic lesions. An orderly and thorough examination of the head and neck with an appropriate directed workup will facilitate the diagnosis. The most common entities occur repeatedly within the various age groups and can be differentiated with a clear understanding of embryology and anatomy of the region, and an understanding of the natural history of a specific lesion. Congenital lesions most commonly found in the pediatric population include the thyroglossal duct cyst and the branchial cleft and arch anomalies. The inflammatory masses are secondary to local or systemic infections. The most common etiology for cervical adenopathy in children is reactive lymphadenopathy following a viral or bacterial illness. Persistent adenopathy raises more concerns, especially enlarged lymph nodes within the posterior triangle or supraclavicular space, nodes that are painless, firm, and not mobile, or a single dominant node that persists for more than 6 weeks should all heighten concern for malignancy. In this review, we discuss the current principles of surgical management of the most common head and neck masses that present to pediatricians and pediatric surgeons.

  1. Creating Gaze Annotations in Head Mounted Displays

    DEFF Research Database (Denmark)

    Mardanbeigi, Diako; Qvarfordt, Pernilla

    2015-01-01

    To facilitate distributed communication in mobile settings, we developed GazeNote for creating and sharing gaze annotations in head mounted displays (HMDs). With gaze annotations it possible to point out objects of interest within an image and add a verbal description. To create an annota- tion...

  2. 29 CFR 1917.93 - Head protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Head protection. 1917.93 Section 1917.93 Labor Regulations... of the following consensus standards: (i) ANSI Z89.1-2003, “American National Standard for Industrial... constructed in accordance with one of the above consensus standards will be deemed to be in compliance with...

  3. Addressing Tooth Decay in Head Start Children

    Science.gov (United States)

    Knowlden, Adam P.; Hill, Lawrence F.; Alles-White, Monica L.; Cottrell, Randall R.

    2012-01-01

    Tooth decay is the most prevalent chronic disease of childhood. Oral health education and dental services are crucial to reducing the number of children afflicted with dental cavities. Due to limited access to preventative care, Head Start children are particularly vulnerable to tooth decay. This article outlines practical implications of a…

  4. Neurosurgery for management of severe head injury

    International Nuclear Information System (INIS)

    Seitz, K.; Richter, H.P.

    1998-01-01

    Neurosurgery as a treatment of severe head injuries is not restricted to invasive surgery but also includes peri-operative intensive care medicine. Thanks to the technological progress and advanced diagnostic tools, especially drug treatments and their efficiency as well as risks can be far better monitored and analysed today. (orig./CB) [de

  5. Unilateral otolith centrifugation by head tilt

    NARCIS (Netherlands)

    Winters, S.M.; Bos, J.E.; Klis, S.F.L.

    2014-01-01

    BACKGROUND: To test for otolith asymmetries, several studies described horizontal translation of the body and head en bloc during fast vertical axis rotation. This stimulus causes one otolithic organ to rotate on-axis, and the other to experience centripetal acceleration. OBJECTIVE: To test a new,

  6. Otolith function in patients with head trauma.

    Science.gov (United States)

    Lee, Jong Dae; Park, Moo Kyun; Lee, Byung Don; Park, Ji Yun; Lee, Tae Kyung; Sung, Ki-Bum

    2011-10-01

    This study evaluates the otolith function of patients with head trauma, postulating that otolith dysfunction is a cause of nonspecific dizziness after head trauma. We prospectively enrolled 28 patients referred within 3 months after head trauma between March 2007 and December 2009. Pure tone audiometry, caloric testing and otolith function tests, including cervical vestibular evoked myogenic potential (cVEMP) and subjective visual vertical (SVV) tests, were performed on all patients. The relationship between otolith function and otologic symptoms was analyzed. Of the 28 patients with head trauma, 18 complained of dizziness and 12 experienced hearing loss, including 6 patients who complained of both. On defining otolith dysfunction as an abnormal cVEMP or abnormal SVV, a significant difference in otolith dysfunction existed between the groups with and without dizziness [72 (13/18) vs. 20% (2/10)]. In contrast, no significant difference in otolith dysfunction was detected between the abnormal and normal hearing groups. A significant number of the patients who complained of nonspecific dizziness after trauma had abnormal otolith function. After trauma, when patients complain of dizziness, vestibular function tests, including otolith function tests, should be considered.

  7. Multicystic encephalopathy in abusive head trauma

    NARCIS (Netherlands)

    Kubat, Bela; Bilo, Rob A. C.; van Rijn, Rick R.

    2014-01-01

    The proof of abusive head trauma (AHT) in infants is difficult, especially in cases with a long posttraumatic survival period. In the acute phase, injury to the cranio-cervical junction causes disturbances in respiratory and cardiac control, leading to apnea and bradycardia. Infants who survive the

  8. Femoral head vitality after intracapsular hip fracture

    International Nuclear Information System (INIS)

    Stroemqvist, B.

    1983-01-01

    Femoral head vitality before, during and at various intervals from the operation was determined by tetracycline labeling and/or 99 sp (m)Tc-MDP scintimetry. In a three-year follow-up, healing prognosis could be determined by scintimetry 3 weeks from operation; deficient femoral head vitality predicting healing complications and retained vitality predicting uncomplicated healing. A comparison between pre- and postoperative scintimetry indicated that further impairment of the femoral head vitality could be caused by the operative procedure, and as tetracycline labeling prior to and after fracture reduction in 370 fractures proved equivalent, it was concluded that the procedure of osteosynthesis probably was responsible for capsular vessel injury, using a four-flanged nail. The four-flanged nail was compared with a low-traumatic method of osteosynthesis, two hook-pins, in a prospective randomized 14 month study, and the postoperative femoral head vitality was significantly better in the hook-pin group. This was also clearly demonstrated in a one-year follow-up for the fractures included in the study. Parallel to these investigations, the reliability of the methods of vitality determination was found satisfactory in methodologic studies. For clinical purpose, primary atraumatic osteosynthesis, postoperative prognostic scintimetry and early secondary arthroplasty when indicated, was concluded to be the appropriate approach to femoral neck fracture treatment. (Author)

  9. Nutrition in Patients with Head Trauma

    Directory of Open Access Journals (Sweden)

    Burcu Totur

    2013-01-01

    Full Text Available The need of energy increases by 40% in patients with a head trauma, when compared to people who are living a normal life. This ratio reaches to 200% in some cases. It is important to give a nutrition support which can satisfy the energy need resulted from the hypermetabolic and hypercatabolic states and that is enough to help to fix the immunologic state and achieve a better result in healing the injury. When oral nutrition is not possible in the patient with a head trauma, their energy need is satisfied through enteral and parenteral nutrition. Though parenteral nutrition had held an important role in feeding patients with head trauma, enteral nutrition is applied much more widely today. Enteral and parenteral nutrition both has their own advantages and disadvantages. In the clinical and laboratory studies that had been held, it was found that enteral nutrition improved the systemic immunity, decreased the incidence of the major infectious complications, decreased the metabolic response to trauma, protected the intestinal mucosa, and protected the ecologic balance of the microflora. In this article, it is investigated through the importance of the feeding in patients with a head trauma and reasons to chose enteral nutrition

  10. An Overview of Head Start Program Studies

    Science.gov (United States)

    Hines, Jeanne Morris

    2017-01-01

    Johnson's "War on Poverty" administrative team campaigned for committee members to join the War on Poverty efforts to create and develop programs for children born into poverty (Zigler, 2003). Poverty based programs, such as the Head Start program, continue to put into place proactive measures to increase preschooler's cognitive…

  11. Department-Head Leadership for School Improvement

    Science.gov (United States)

    Leithwood, Kenneth

    2016-01-01

    This review of research was prompted by the widespread belief that at least in a significant number of secondary schools, department heads are an underutilized, if not untapped, source of instructional leadership, the type of leadership critical to secondary-school improvement initiatives. Forty-two methodologically diverse empirical studies were…

  12. Kiirlaenud kohe vastuolus heade kommetega / Anne Oja

    Index Scriptorium Estoniae

    Oja, Anne, 1970-

    2008-01-01

    Seaduseelnõust, mis kuulutab heade kommetega vastuolus olevaiks ning tühiseiks laenutehingud, kus laenuvõtja suudab hiljem tõendada oma erakorralisi vajadusi, sõltuvussuhet, kogenematust või muid selliseid asjaolusid ning väidab, et talle tehti laenu andes liiga

  13. Head And Neck Rhabdomyosacroma In Childhood: An ...

    African Journals Online (AJOL)

    Background: Rhabdomyosarcoma may be histologically indistinguishable from other undifferentiated childhood tumours occurring in the head and neck region on routine heamatoxylin and eosin staining. Aim: aimed at assessing the usefulness of employing immunohistochemistry, as an adjunct to routine H&E staining, ...

  14. Target definition in prostate, head, and neck

    NARCIS (Netherlands)

    Rasch, Coen; Steenbakkers, Roel; van Herk, Marcel

    2005-01-01

    Target definition is a major source of errors in both prostate and head and neck external-beam radiation treatment. Delineation errors remain constant during the course of radiation and therefore have a large impact on the dose to the tumor. Major sources of delineation variation are visibility of

  15. 33 CFR 142.30 - Head protection.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Head protection. 142.30 Section 142.30 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OUTER... protection. (a) Personnel in areas where there is a hazard of falling objects or of contact with electrical...

  16. Adaptive algorithm of magnetic heading detection

    Science.gov (United States)

    Liu, Gong-Xu; Shi, Ling-Feng

    2017-11-01

    Magnetic data obtained from a magnetic sensor usually fluctuate in a certain range, which makes it difficult to estimate the magnetic heading accurately. In fact, magnetic heading information is usually submerged in noise because of all kinds of electromagnetic interference and the diversity of the pedestrian’s motion states. In order to solve this problem, a new adaptive algorithm based on the (typically) right-angled corridors of a building or residential buildings is put forward to process heading information. First, a 3D indoor localization platform is set up based on MPU9250. Then, several groups of data are measured by changing the experimental environment and pedestrian’s motion pace. The raw data from the attached inertial measurement unit are calibrated and arranged into a time-stamped array and written to a data file. Later, the data file is imported into MATLAB for processing and analysis using the proposed adaptive algorithm. Finally, the algorithm is verified by comparison with the existing algorithm. The experimental results show that the algorithm has strong robustness and good fault tolerance, which can detect the heading information accurately and in real-time.

  17. Aseptic necrosis of femoral head complicating thalassemia

    International Nuclear Information System (INIS)

    Orzincolo, C.; Castaldi, G.; Scutellary, P.N.; Bariani, L.; Pinca, A.

    1986-01-01

    Aseptic necrosis of the femoral head is described in 4 patients, selected from 280 patients with homozygous β-thalassemia (Cooley anemia). The incidence of the complication appears to be very high (14.5per mille) in thalassemia, compared to the general population. The possible mechanism are discussed. (orig.)

  18. Rule customization in head-up games

    NARCIS (Netherlands)

    Toering, E.B.; Soute, I.A.C.; Markopoulos, P.

    2010-01-01

    This research examines the feasibility of rule customization for a genre of pervasive games for children called Head-Up Games [11], which are intended to be played outdoors by children and to encourage physical activity and social interaction. An interface to allow customization of game rules was

  19. 3-Dimensional Reproducibility of Natural Head Position

    Science.gov (United States)

    2012-04-12

    the “Six Elements to Orofacial Harmony”. He advocated using his Element II Analysis with natural head orientation for treatment planning, since “it...temporomandibular disorders, neck pain , headache, dentofacial structures, mandibular length, mandibular position, mandibular divergency and overjet (Cuccia, 2009

  20. The Great Irish Head Shop Controversy

    Science.gov (United States)

    Ryall, Graham; Butler, Shane

    2011-01-01

    This research describes and analyses recent policy developments in Ireland in relation to the practice of selling psychoactive substances which, while not themselves illegal, mimic the effects of commonly used illegal drugs. These so-called "legal highs" had been sold in Ireland through an increasing number of "head shops"…

  1. Driving with head-slaved camera system

    NARCIS (Netherlands)

    Oving, A.B.; Erp, J.B.F. van

    2001-01-01

    In a field experiment, we tested the effectiveness of a head-slaved camera system for driving an armoured vehicle under armour. This system consists of a helmet-mounted display (HMD), a headtracker, and a motion platform with two cameras. Subjects performed several driving tasks on paved and in

  2. Mechatronic design of the Twente humanoid head

    NARCIS (Netherlands)

    Reilink, Rob; Visser, L.C.; Brouwer, Dannis Michel; Carloni, Raffaella; Stramigioli, Stefano

    This paper describes the mechatronic design of the Twente humanoid head, which has been realized in the purpose of having a research platform for human-machine interaction. The design features a fast, four degree of freedom neck, with long range of motion, and a vision system with three degrees of

  3. Oral sequelae of head and neck radiotherapy

    NARCIS (Netherlands)

    Vissink, A; Jansma, J; Spijkervet, FKL; Burlage, FR; Coppes, RP

    In addition to anti-tumor effects, ionizing radiation causes damage in normal tissues located in the radiation portals. Oral complications of radiotherapy in the head and neck region are the result of the deleterious effects of radiation on, e. g., salivary glands, oral mucosa, bone, dentition,

  4. Catalogue of tooth brush head designs.

    Science.gov (United States)

    Voelker, Marsha A; Bayne, Stephen C; Liu, Ying; Walker, Mary P

    2013-06-01

    Manual toothbrushes (MTBs) and power toothbrushes (PTBs) are effective oral physiotherapy aids for plaque removal. End-rounded bristles are safer and reduce damage to oral tissues. Nylon bristles are more effective in plaque removal because the bristle is stiffer than natural bristles. In the last 10 years the number of options for MTBs and PTBs has expanded significantly and there is very little information providing a reference frame for the design characteristics of the heads. The present in vitro study characterized a variety of MTB and PTB heads to provide a reference library for other research comparisons which might be made. Various commercial MTB and PTB heads were used to characterize the following: bristle size, shape, diameter, number of tufts, number of bristles per tuft and surface characteristics. Photographs were collected from the side, at 45 degrees and the top of each toothbrush (TB) head using a scanning electron microscope and digital camera. Images were analyzed (Soft Imaging System) for bristle features and designs. One-way ANOVA (p ≤ 0.05) was performed to detect differences among TB types within MTB and PTB groups and between pooled values for MTB and PTB groups. There were significant differences (p ≤ 0.05) in toothbrush bristle diameter and bristle shape. In contrast, there were no significant differences between PTB vs. MTB in regards to bristle diameter, bristle count and tuft count. The results suggest that although there are wide variations in toothbrush head designs, significant differences were found only in relation to bristle diameter and shape.

  5. The immunologic considerations in human head transplantation.

    Science.gov (United States)

    Hardy, Mark A; Furr, Allen; Barret, Juan P; Barker, John H

    2017-05-01

    The idea of head transplantation appears at first as unrealistic, unethical, and futile. Here we discuss immunological considerations in human head transplantation. In a separate accompanying article we discuss surgical, ethical, and psychosocial issues concerned in body-to-head transplantation (BHT) [1]. The success of such an unusual allograft, where the donor and the recipient can reject each other, depends on prevention of complex immunologic reactions, especially rejection of the head by the body (graft-vs-host) or probably less likely, the possibility of the head rejecting the total body allograft (host-vs-graft). The technical and immunologic difficulties are enormous, especially since rapid nerve and cord connections and regeneration have not yet been possible to achieve. In this article we begin by briefly reviewing neuro-immunologic issues that may favor BHT such as the blood brain barrier (BBB) and point out its shortcomings. And we touch on the cellular and humoral elements in the brain proper that differ in some respects from those in other organs and in the periphery. Based on recent successes in vascular composite allografts (VCAs), we will elaborate on potential specific advantages and difficulties in BHT of various available immunosuppressive medications already utilized in VCAs. The risk/benefit ratio of these drugs will be emphasized in relation to direct brain toxicity such as seizure disorders, interference, or promotion of nerve regeneration, and potentiation of cerebral viral infections. The final portion of this article will focus on pre-transplant immunologic manipulation of the deceased donor body along with pretreatment of the recipient. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  6. Kinematics of the human mandible for different head postures.

    Science.gov (United States)

    Visscher, C M; Huddleston Slater, J J; Lobbezoo, F; Naeije, M

    2000-04-01

    The influence of head posture on movement paths of the incisal point (IP) and of the mandibular condyles during free open-close movements was studied. Ten persons, without craniomandibular or cervical spine disorders, participated in the study. Open close mandibular movements were recorded with the head in five postures, viz., natural head posture, forward head posture, military posture, and lateroflexion to the right and to the left side, using the Oral Kinesiologic Analysis System (OKAS-3D). This study showed that in a military head posture, the opening movement path of the incisal point is shifted anteriorly relative to the path in a natural head posture. In a forward head posture, the movement path is shifted posteriorly whereas during lateroflexion, it deviates to the side the head has moved to. Moreover, the intra-articular distance in the temporomandibular joint during closing is smaller with the head in military posture and greater in forward head posture, as compared to the natural head posture. During lateroflexion, the intra-articular distance on the ipsilateral side is smaller. The influence of head posture upon the kinematics of the mandible is probably a manifestation of differences in mandibular loading in the different head postures.

  7. Handling and carrying head for nuclear fuel assemblies and installation including this head

    International Nuclear Information System (INIS)

    Artaud, R.; Cransac, J.P.; Jogand, P.

    1986-01-01

    The present invention proposes a handling and carrying head ensuring efficiently the cooling of the nuclear fuel asemblies it transports so that any storage in liquid metal in a drum within or adjacent the reactor vessel is suppressed. The invention claims also a nuclear fuel handling installation including the head; it allows a longer time between loading and unloading campaigns and the space surrounding the reactor vessel keeps free without occupying a storage zone within the vessel [fr

  8. Genetics Home Reference: head and neck squamous cell carcinoma

    Science.gov (United States)

    ... and neck squamous cell carcinoma Head and neck squamous cell carcinoma Printable PDF Open All Close All Enable Javascript ... Consumer Version: Overview of Mouth, Nose, and Throat Cancers Orphanet: Squamous cell carcinoma of head and neck University of Michigan ...

  9. 21 CFR 892.1920 - Radiographic head holder.

    Science.gov (United States)

    2010-04-01

    ...) Identification. A radiographic head holder is a device intended to position the patient's head during a... device is also exempt from the current good manufacturing practice requirements of the quality system...

  10. Allocation of Attention with Head-Up Displays

    National Research Council Canada - National Science Library

    Wickens, C

    1998-01-01

    Two experiments examined the effects of display location (head up vs. head down) and image intensity/clutter on flight path performance and mid-air target detection in a general aviation cruise flight environment...

  11. Head and Neck Cancer—Health Professional Version

    Science.gov (United States)

    Head and neck cancers include hypopharyngeal, laryngeal, lip and oral cavity, metastatic squamous neck, nasopharyngeal, oropharyngeal, paranasal sinus, and salivary gland cancers. Find evidence-based information on head and neck cancer treatment, causes and prevention, research, screening, and statistics.

  12. Heading Frequency Is More Strongly Related to Cognitive Performance Than Unintentional Head Impacts in Amateur Soccer Players

    Directory of Open Access Journals (Sweden)

    Walter F. Stewart

    2018-04-01

    Full Text Available ObjectiveCompared to heading, unintentional head impacts (e.g., elbow to head, head to head, head to goalpost in soccer are more strongly related to risk of moderate to very severe Central Nervous System (CNS symptoms. But, most head impacts associated with CNS symptoms that occur in soccer are mild and are more strongly related to heading. We tested for a differential relation of heading and unintentional head impacts with neuropsychological (NP test performance.MethodActive adult amateur soccer players were recruited in New York City and the surrounding areas for this repeated measures longitudinal study of individuals who were enrolled if they had 5+ years of soccer play and were active playing soccer 6+ months/year. All participants completed a baseline validated questionnaire (“HeadCount-2w”, reporting 2-week recall of soccer activity, heading and unintentional head impacts. In addition, participants also completed NP tests of verbal learning, verbal memory, psychomotor speed, attention, and working memory. Most participants also completed one or more identical follow-up protocols (i.e., HeadCount-2w and NP tests at 3- to 6-month intervals over a 2-year period. Repeated measures General Estimating Equations (GEE linear models were used to determine if variation in NP tests at each visit was related to variation in either heading or unintentional head impacts in the 2-week period before testing.Results308 players (78% male completed 741 HeadCount-2w. Mean (median heading/2-weeks was 50 (17 for men and 26 (7 for women. Heading was significantly associated with poorer performance on psychomotor speed (p < 0.001 and attention (p = 0.02 tasks and was borderline significant with poorer performance on the working memory (p = 0.06 task. Unintentional head impacts were not significantly associated with any NP test. Results did not differ after excluding 22 HeadCount-2w with reported concussive or borderline concussive symptoms

  13. Multigenerational Head Start Participation: An Unexpected Marker of Progress

    Science.gov (United States)

    Chor, Elise

    2018-01-01

    One-quarter of the Head Start population has a mother who participated in the program as a child. This study uses experimental Head Start Impact Study (HSIS) data on 3- and 4-year-olds (N = 2,849) to describe multigenerational Head Start families and their program experiences. In sharp contrast to full-sample HSIS findings, Head Start has large,…

  14. Head Start Participants, Programs, Families and Staff in 2013

    Science.gov (United States)

    Walker, Christina

    2014-01-01

    Head Start programs provide poor children and their families with comprehensive early education and support services. Each year, programs are required to submit a Program Information Report (PIR) to the Office of Head Start on participating children, pregnant women, and families, as well as the staff serving the Head Start population. In 2013, the…

  15. The Role of Classroom Quality in Explaining Head Start Impacts

    Science.gov (United States)

    Connors, Maia C.; Friedman-Krauss, Allison H.; Morris, Pamela A.; Page, Lindsay C.; Feller, Avi

    2014-01-01

    This study seeks to answer the following question: Are impacts on Head Start classroom quality associated with impacts of Head Start on children's learning and development? This study employs a variety of descriptive and quasi-experimental methods to explore the role of classroom quality as a mediator or mechanism of Head Start impacts. This…

  16. Do Head Start Impacts Vary by Neighborhood Context?

    Science.gov (United States)

    Morris, Pamela A.; Connors, Maia C.; McCoy, Dana Charles; Gomez, Celia J.; Yoshikawa, Hiro; Aber, J. Lawrence

    2014-01-01

    This paper capitalizes on the addition of geocodes for Head Start centers in which children were randomly assigned to address questions about the role of neighborhood characteristics in moderating impacts of assignment to the Head Start program. Researchers explore the extent to which impacts of assignment to Head Start on outcomes for children…

  17. Head Start Instructional Professionals' Inclusion Perceptions and Practices

    Science.gov (United States)

    Muccio, Leah S.; Kidd, Julie K.; White, C. Stephen; Burns, M. Susan

    2014-01-01

    This study considered the facilitators and barriers of successful inclusion in Head Start classrooms by examining the perspectives and practices of instructional professionals. A cross-sectional survey design was combined with direct observation in inclusive Head Start classrooms. Survey data were collected from 71 Head Start instructional…

  18. Enhancing Early Childhood Outcomes: Connecting Child Welfare and Head Start

    Science.gov (United States)

    McCrae, Julie S.; Brown, Samantha M.; Yang, Jessica; Groneman, Sheila

    2016-01-01

    Head Start is a preschool program for families with low incomes and nearly 85% of child welfare-involved families are low-income, yet little is known about Head Start and child welfare collaboration. This study uses data from 28 Head Start directors to describe collaboration facilitators and barriers, and collaborative mechanisms in place. The…

  19. Computerised tomographic patterns in patients with head injury at ...

    African Journals Online (AJOL)

    2011-04-15

    Apr 15, 2011 ... The clinical severity of head injury is classified based on ... head injury include road traffic accidents (RTA), assaults, ... information in the management of patients with head ... Materials and Methods ... The right cerebral hemisphere was involved in 13 cases .... Nerve palsies – 3rd, 5th, 6th cranial nerves. 3.

  20. Topographic Pattern Distribution of Head And Neck Squamous Cell ...

    African Journals Online (AJOL)

    FINEPRINT

    value of 71% of SCC in Turkey. Nevertheless a similar report documented a relatively lower value especially in. Yemen where head and neck SCC constituted only 8% of all head and neck cancers. Reports from Yemen revealed that oral cavity SCC was the most common topographic site of all head and. 3 neck cancers.

  1. PRACTICAL MANAGEMENT OF HEAD INJURY | Shehu | Annals of ...

    African Journals Online (AJOL)

    For an effective practical management of head injury, a clear knowledge of the various causes and mechanism of head injury is essential. The concept of the brain in a rigid cranial cavity makes the pathophysiological mechanism of head trauma unique. Most problems occur due to poor handling of patients at the site of ...

  2. 21 CFR 868.5560 - Gas mask head strap.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas mask head strap. 868.5560 Section 868.5560...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5560 Gas mask head strap. (a) Identification. A gas mask head strap is a device used to hold an anesthetic gas mask in position on a patient's...

  3. Antipredatory function of head shape for vipers and their mimics.

    Directory of Open Access Journals (Sweden)

    Janne K Valkonen

    Full Text Available Most research into the adaptive significance of warning signals has focused on the colouration and patterns of prey animals. However, behaviour, odour and body shape can also have signal functions and thereby reduce predators' willingness to attack defended prey. European vipers all have a distinctive triangular head shape; and they are all venomous. Several non-venomous snakes, including the subfamily Natricinae, commonly flatten their heads (also known as head triangulation when disturbed. The adaptive significance of this potential behavioural mimicry has never been investigated.We experimentally tested if the triangular head shape typical of vipers offers protection against predation. We compared the predation pressure of free-ranging predators on artificial snakes with triangular-shaped heads against the pressure on replicas with narrow heads. Snakes of both head types had either zigzag patterned bodies, typical of European vipers, or plain (patternless bodies. Plain snakes with narrower Colubrid-like heads suffered significantly higher predation by raptors than snakes with triangular-shaped heads. Head shape did not, however, have an additive effect on survival in zigzag-patterned snakes, suggesting that species which differ from vipers in colouration and pattern would benefit most from behavioural mimicry. Our results demonstrate that the triangular head shape typical of vipers can act as a warning signal to predators. We suggest that head-shape mimicry may be a more common phenomenon among more diverse taxa than is currently recognised.

  4. 49 CFR 572.142 - Head assembly and test procedure.

    Science.gov (United States)

    2010-10-01

    ... acceleration versus time history curve shall be unimodal, and the oscillations occurring after the main pulse... for testing. (3) Suspend the head assembly with its midsagittal plane in vertical orientation as shown... head in transverse alignment with the CG, shall be used to ensure that the head transverse plane is...

  5. SmoothMoves : Smooth pursuits head movements for augmented reality

    NARCIS (Netherlands)

    Esteves, Augusto; Verweij, David; Suraiya, Liza; Islam, Rasel; Lee, Youryang; Oakley, Ian

    2017-01-01

    SmoothMoves is an interaction technique for augmented reality (AR) based on smooth pursuits head movements. It works by computing correlations between the movements of on-screen targets and the user's head while tracking those targets. The paper presents three studies. The first suggests that head

  6. 21 CFR 882.4460 - Neurosurgical head holder (skull clamp).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical head holder (skull clamp). 882.4460... holder (skull clamp). (a) Identification. A neurosurgical head holder (skull clamp) is a device used to clamp the patient's skull to hold head and neck in a particular position during surgical procedures. (b...

  7. Pattern of head and neck cancers among patients attending ...

    African Journals Online (AJOL)

    Lack of baseline data in Tanzania concerning head and ... that there is a synergistic effect of alcohol consumption and tobacco use in causing head and neck cancers ... risk factors, while radiation around the head and neck is associated with ...

  8. Maccoby's Head/Heart Traits: Marketing versus Accounting Students.

    Science.gov (United States)

    Kochunny, C. M.; And Others

    1992-01-01

    Nineteen head/heart traits derived from Maccoby's business ethics work were rated on importance to future careers by 148 marketing and 178 accounting students. Both groups rated head traits as most important. Marketing majors are not as "games" oriented as social stereotypes would indicate. The apparent imbalance between head and heart traits…

  9. Lower head integrity under steam explosion loads

    Energy Technology Data Exchange (ETDEWEB)

    Theofanous, T.G.; Yuen, W.W.; Angelini, S.; Freeman, K.; Chen, X.; Salmassi, T. [Center for Risk Studies and Safety, Univ. of California, Santa Barbara, CA (United States); Sienicki, J.J.

    1998-01-01

    Lower head integrity under steam explosion loads in an AP600-like reactor design is considered. The assessment is the second part of an evaluation of the in-vessel retention idea as a severe accident management concept, the first part (DOE/ID-10460) dealing with thermal loads. The assessment is conducted in terms of the Risk Oriented Accident Analysis Methodology (ROAAM), and includes the comprehensive evaluation of all relevant severe accident scenarios, melt conditions and timing of release from the core region, fully 3D mixing and explosion wave dynamics, and lower head fragility under local, dynamic loading. All of these factors and brought together in a ROAAM Probabilistic Framework to evaluate failure likelihood. The conclusion is that failure is `physically unreasonable`. (author)

  10. Optical fiber head for providing lateral viewing

    Science.gov (United States)

    Everett, Matthew J.; Colston, Billy W.; James, Dale L.; Brown, Steve; Da Silva, Luiz

    2002-01-01

    The head of an optical fiber comprising the sensing probe of an optical heterodyne sensing device includes a planar surface that intersects the perpendicular to axial centerline of the fiber at a polishing angle .theta.. The planar surface is coated with a reflective material so that light traveling axially through the fiber is reflected transverse to the fiber's axial centerline, and is emitted laterally through the side of the fiber. Alternatively, the planar surface can be left uncoated. The polishing angle .theta. must be no greater than 39.degree. or must be at least 51.degree.. The emitted light is reflected from adjacent biological tissue, collected by the head, and then processed to provide real-time images of the tissue. The method for forming the planar surface includes shearing the end of the optical fiber and applying the reflective material before removing the buffer that circumscribes the cladding and the core.

  11. Small and low head pumped storage projects

    International Nuclear Information System (INIS)

    Makarechian, A.H.

    1991-01-01

    The purpose of this paper is to focus attention on small and low head pumped storage projects. These projects may be defined as having a capacity of less than 200-300 MW and down to about 20 MW, with heads of 1200 ft to about 300 ft or less. Many advantages of these smaller pumped storage projects include more flexibility in siting of a project, considerably shorter licensing and construction period, adaptability to closed system design concept to reduce adverse environmental impacts, considerably reduced risks of delays and substantial cost over-runs, better suited to meeting peaking capacity requirements for individual utilities, and much less transmission inter-connection requirements. An overall licensing and construction schedule of about 3 to 3 1/2 years is realistic for many smaller pumped storage projects, and competitive costs in terms of dollars per kW installed can be achieved

  12. Exploding Head Syndrome:A Case Report

    Directory of Open Access Journals (Sweden)

    Gautam Ganguly

    2013-01-01

    Full Text Available Introduction: Exploding head syndrome (EHS is a rare parasomnia in which affected individuals awaken from sleep with the sensation of a loud bang. The etiology is unknown, but other conditions including primary and secondary headache disorders and nocturnal seizures need to be excluded. Case Presentation: A 57-year-old Indian male presented with four separate episodes of awakening from sleep at night after hearing a flashing sound on the right side of his head over the last 2 years. These events were described ‘as if there are explosions in my head’. A neurologic examination, imaging studies, and a polysomnogram ensued, and the results led to the diagnosis of EHS. Conclusion: EHS is a benign, uncommon, predominately nocturnal disorder that is self-limited. No treatment is generally required. Reassurance to the patient is often all that is needed.

  13. Delayed epidural hematoma after mild head injury

    Directory of Open Access Journals (Sweden)

    Radulović Danilo

    2005-01-01

    Full Text Available Background. Traumatic delayed epidural hematoma (DEH can be defined as insignificant or not seen on the initial CT scan performed after a trauma but seen on the subsequent CT scan as a “massive” epidural bleeding. Case report. We presented two cases of traumatic DEH after mild head injury. Both patients were conscious and without neurological deficit on the admission. Initial CT scan did not reveal intracranial hematoma. Repeated CT scan, that was performed after neurological deterioration, revealed epidural hematoma in both cases. The patients were operated with a favorable surgical outcome. Conclusion. Traumatic DEH could occur in the patients with head injuries who were conscious on the admission with a normal initial CT scan finding. Early detection of DEH and an urgent surgical evacuation were essential for a good outcome.

  14. Imaging of head and neck venous malformations

    International Nuclear Information System (INIS)

    Flis, Christine M.; Connor, Stephen E.

    2005-01-01

    Venous malformations (VMs) are non proliferative lesions that consist of dysplastic venous channels. The aim of imaging is to characterise the lesion and define its anatomic extent. We will describe the plain film, ultrasound (US) (including colour and duplex Doppler), computed tomography (CT), magnetic resonance imaging (MRI), conventional angiographic and direct phlebographic appearances of venous malformations. They will be illustrated at a number of head and neck locations, including orbit, oral cavity, superficial and deep facial space, supraglottic and intramuscular. An understanding of the classification of such vascular anomalies is required to define the correct therapeutic procedure to employ. Image-guided sclerotherapy alone or in combination with surgery is now the first line treatment option in many cases of head and neck venous malformations, so the radiologist is now an integral part of the multidisciplinary management team. (orig.)

  15. Head raising analysis and case revaluation

    Directory of Open Access Journals (Sweden)

    Ager Gondra

    2015-12-01

    Full Text Available This paper shows that Basque relative clause construction follows the Head Raising Analysis: the CP of the relative clause is a complement to the external D and the Head of the relative clause, base-generated inside the TP, moves to the specifier position of the CP. This analysis predicts that the raised DPwill show a TP-internal Case. However, this is not the case, and the DP manifests the Case associated with the main clause. In order to address these Case inconsistencies, Precariousness Condition is proposed. This condition states that a DCase valued u-feature is precarious until it is sent to Spell-Out and therefore, the value is visible for further targeting by a c-commanding Probe.  Evidence for this multiple Agree operation comes from a DP long distance extraction.

  16. Right thalamic infarction after closed head injury

    International Nuclear Information System (INIS)

    Nagaya, Takashi; Doi, Terushige; Katsumata, Tsuguo; Kuwayama, Naoto

    1986-01-01

    We reported a case of right thalamic infarction after a closed head injury. A 12-year-old boy was hit by an autotruck. He was semi-comatose, with left temporal scalp swelling and excoriation in the left lower limb. Three days after the accident, he exhibited left hemiparesis. CT scans on the day of the accident showed no abnormality, but on the following day, right thalamic infarction appeared. Right carotid angiography showed only an irregular vascular shadow in the cisternal segment of the right internal carotid artery. Vascular obstruction after closed head injury is rare, especially in the intracranial vessels, and several pathogeneses may be postulated. The right thalamic infarction in this case was supposed to be due to the damage of the perforators from the right posterior communicating artery and the right posterior cerebral artery, which were struck as a contre-coup by the force from the left side. (author)

  17. Meteor head echoes - observations and models

    Directory of Open Access Journals (Sweden)

    A. Pellinen-Wannberg

    2005-01-01

    Full Text Available Meteor head echoes - instantaneous echoes moving with the velocities of the meteors - have been recorded since 1947. Despite many attempts, this phenomenon did not receive a comprehensive theory for over 4 decades. The High Power and Large Aperture (HPLA features, combined with present signal processing and data storage capabilities of incoherent scatter radars, may give an explanation for the old riddle. The meteoroid passage through the radar beam can be followed with simultaneous spatial-time resolution of about 100m-ms class. The current views of the meteor head echo process will be presented and discussed. These will be related to various EISCAT observations, such as dual-frequency target sizes, altitude distributions and vector velocities.

  18. Proteome reference map of Drosophila melanogaster head.

    Science.gov (United States)

    Lee, Tian-Ren; Huang, Shun-Hong; Lee, Chi-Ching; Lee, Hsiao-Yun; Chan, Hsin-Tzu; Lin, Kuo-Sen; Chan, Hong-Lin; Lyu, Ping-Chiang

    2012-06-01

    Drosophila melanogaster has been used as a genetic model organism to understand the fundamental molecular mechanisms in human biology including memory formation that has been reported involving protein synthesis and/or post-translational modification. In this study, we employed a proteomic platform based on fluorescent 2DE and MALDI-TOF MS to build a standard D. melanogaster head proteome map for proteome-proteome comparison. In order to facilitate the comparison, an interactive database has been constructed for systematically integrating and analyzing the proteomes from different conditions and further implicated to study human diseases related to D. melanogaster model. In summary, the fundamental head proteomic database and bioinformatic analysis will be useful for further elucidating the biological mechanisms such as memory formation and neurodegenerative diseases. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Heading Frequency Is More Strongly Related to Cognitive Performance Than Unintentional Head Impacts in Amateur Soccer Players.

    Science.gov (United States)

    Stewart, Walter F; Kim, Namhee; Ifrah, Chloe; Sliwinski, Martin; Zimmerman, Molly E; Kim, Mimi; Lipton, Richard B; Lipton, Michael L

    2018-01-01

    Compared to heading, unintentional head impacts (e.g., elbow to head, head to head, head to goalpost) in soccer are more strongly related to risk of moderate to very severe Central Nervous System (CNS) symptoms. But, most head impacts associated with CNS symptoms that occur in soccer are mild and are more strongly related to heading. We tested for a differential relation of heading and unintentional head impacts with neuropsychological (NP) test performance. Active adult amateur soccer players were recruited in New York City and the surrounding areas for this repeated measures longitudinal study of individuals who were enrolled if they had 5+ years of soccer play and were active playing soccer 6+ months/year. All participants completed a baseline validated questionnaire ("HeadCount-2w"), reporting 2-week recall of soccer activity, heading and unintentional head impacts. In addition, participants also completed NP tests of verbal learning, verbal memory, psychomotor speed, attention, and working memory. Most participants also completed one or more identical follow-up protocols (i.e., HeadCount-2w and NP tests) at 3- to 6-month intervals over a 2-year period. Repeated measures General Estimating Equations (GEE) linear models were used to determine if variation in NP tests at each visit was related to variation in either heading or unintentional head impacts in the 2-week period before testing. 308 players (78% male) completed 741 HeadCount-2w. Mean (median) heading/2-weeks was 50 (17) for men and 26 (7) for women. Heading was significantly associated with poorer performance on psychomotor speed ( p  impacts were not significantly associated with any NP test. Results did not differ after excluding 22 HeadCount-2w with reported concussive or borderline concussive symptoms. Poorer NP test performance was consistently related to frequent heading during soccer practice and competition in the 2 weeks before testing. In contrast, unintentional head impacts incurred

  20. Radiofrequency ablation of two femoral head chondroblastomas

    Energy Technology Data Exchange (ETDEWEB)

    Petsas, Theodore [Department of Radiology, University of Patras (Greece); Megas, Panagiotis [Department of Orthopaedic Surgery, University of Patras (Greece)]. E-mail: panmegas@med.upatras.gr; Papathanassiou, Zafiria [Department of Radiology, University of Patras (Greece)

    2007-07-15

    Chondroblastoma is a rare benign cartilaginous bone tumor. Surgical resection is the treatment of choice for pain relief and prevention of further growth. Open surgical techniques are associated with complications, particularly when the tumors are located in deep anatomical sites. The authors performed RF ablation in two cases of subarticular femoral head chondroblastomas and emphasize its positive impact. The clinical course, the radiological findings and the post treatment results are discussed.

  1. The optic nerve head in glaucoma

    Directory of Open Access Journals (Sweden)

    Rupert RA Bourne

    2006-09-01

    Full Text Available ll types of glaucoma involve glaucomatous optic neuropathy. The key to detection and management of glaucoma is understanding how to examine the optic nerve head (ONH. This pictorial glossary addresses the following issues: how to examine the ONH; normal characteristics of the ONH; characteristics of a glaucomatous ONH; how to tell if the glaucomatous optic neuropathy is getting worse;‘pitfalls and pearls’.

  2. Cancer of the head and neck

    International Nuclear Information System (INIS)

    Leignel, D.; Toledano, A.; Calais, G.; Gardner, M.; Valinta, D.; Halimi, P.; Alberini, J.L.; Plantet, M.M.; Banal, A.; Hans, S.; Floiras, J.L.; Labib, A.; Djemaa, A.; Naoun, L.; Bali, M.; Melais, K.; George, L.; Cazalet, M.; Gross, E.; Padovani, L.; Cowen, D.; Pignon, T.; Bannour, N.; Guedouar, R.; Bouaouina, N.; Mege, A.; Lapeyre, M.; Graff, P.; Marchesi, V.; Aletti, P.; Marchal, C.; Peiffert, D.; Serre, A.; Ailleres, N.; Lemanski, C.; Hay, M.H.; Llacer Moscardo, C.; Allaw, A.; Azria, D.; Dubois, J.B.; Fenoglietto, P.; Maalej, M.; Nasr, C.; Chaari, N.; Hentati, D.; Kochbati, L.; Besbes, M.; Benjelloun, H.; Benchakroun, N.; Houjami, M.; Jouhadi, H.; Tawfiq, N.; Acharki, A.; Sahraoui, S.; Benider, A.; Racadot, S.; Mercier, M.; Dessard-Diana, B.; Bensadoun, R.J.; Martin, M.; Malaurie, E.; Favrel, V.; Housset, M.; Journel, C.; Calais, G.; Huet, J.; Pillet, G.; Hennequin, C.; Haddad, E.; Diana, C.; Blaska-Jaulerry, B.; Henry-Amar, M.; Gehanno, P.; Baillet, F.; Mazeron, J.J.; Chaouache, C.K.; Tebra Mrad, T.M.S.; Bannour, B.N.S.; Bouaouina, B.N.; Favrel, V.; Khodri, M.; Chapet, O.; Nguyen, D.; Ardiet, J.; Romestaing, P.; Thillays, F.; Bardet, E.; Rolland, F.; Maingan, P.; Campion, L.; Mahe, M.A.

    2005-01-01

    Thirteen articles are presented in relation with head and neck cancer. Chemoradiotherapy, medical examinations using nuclear techniques such PET scanning, fractionated radiotherapy after a chemotherapy, analysis of dose volume for patients treated by irradiation with a combined chemotherapy, dosimetry, conformal radiotherapy with intensity modulation, dosimetry in brachytherapy, association of radiotherapy and chemotherapy in the treatment of nose pharynx carcinomas, recurrence, are the different subjects treated in this part. (N.C.)

  3. [Avascular necrosis of the femoral head].

    Science.gov (United States)

    Porubský, Peter; Trč, Tomáš; Havlas, Vojtěch; Smetana, Pavel

    Avascular necrosis of the femoral head in adults is not common, but not too rare diseases. In orthopedic practice, it is one of the diseases that are causing implantation of hip replacement at a relatively early age. In the early detection and initiation of therapy can delay the implantation of prosthesis for several years, which is certainly more convenient for the patient and beneficial. This article is intended to acquaint the reader with the basic diagnostic procedures and therapy.

  4. Skin Cancer of the Head and Neck

    OpenAIRE

    Ouyang, Yun-Hsuan

    2010-01-01

    The majority of skin cancers of the head and neck are nonmelanoma skin cancers (NMSC). Basal cell carcinoma and squamous cell carcinoma are the most frequent types of NMSC. Malignant melanoma is an aggressive neoplasm of skin, and the ideal adjuvant therapy has not yet been found, although various options for treatment of skin cancer are available to the patient and physician, allowing high cure rate and excellent functional and cosmetic outcomes. Sunscreen protection and early evaluation of ...

  5. Perspectives about family meals from single-headed and dual-headed households: a qualitative analysis.

    Science.gov (United States)

    Berge, Jerica M; Hoppmann, Caroline; Hanson, Carrie; Neumark-Sztainer, Dianne

    2013-12-01

    Cross-sectional and longitudinal research has shown that family meals are protective for adolescent healthful eating behaviors. However, little is known about what parents think of these findings and whether parents from single- vs dual-headed households have differing perspectives about the findings. In addition, parents' perspectives regarding barriers to applying the findings on family meals in their own homes and suggestions for more widespread adoption of the findings are unknown. The current study aimed to identify single- and dual-headed household parents' perspectives regarding the research findings on family meals, barriers to applying the findings in their own homes, and suggestions for helping families have more family meals. The current qualitative study included 59 parents who participated in substudy of two linked multilevel studies-EAT 2010 (Eating and Activity in Teens) and Families and Eating and Activity in Teens (F-EAT). Parents (91.5% female) were racially/ethnically and socioeconomically diverse. Data were analyzed using a grounded theory approach. Results from the current study suggest that parents from both single- and dual-headed households have similar perspectives regarding why family meals are protective for healthful eating habits for adolescents (eg, provides structure/routine, opportunities for communication, connection), but provide similar and different reasons for barriers to family meals (eg, single-headed=cost vs dual-headed=lack of creativity) and ideas and suggestions for how to increase the frequency of family meals (eg, single-headed=give fewer options vs dual-headed=include children in the meal preparation). Findings can help inform public health intervention researchers and providers who work with adolescents and their families to understand how to approach discussions regarding reasons for having family meals, barriers to carrying out family meals, and ways to increase family meals depending on family structure. Copyright

  6. MR imaging in pancreas head cancer

    International Nuclear Information System (INIS)

    Yokota, Hajime; Yamanouchi, Baisetsu; Takarada, Akira; Tonami, Hisao; Okimura, Tetsuro; Miyamura, Toshio; Yamamoto, Itaru; Kinami, Yoshio

    1989-01-01

    To reduce artifacts associated with MRI, we used abdominal belts and anticholinergic during the examinations in patients with pancreas head cancer. In selected cases, foric pyrophosphate was injected into the common bile duct as a contrast medium. We made a comparative study of the results of MRI with those of CT with regard to lesion detectability and diagnostic ability of tumor invasion. MR examinations were performed at 0.5 Tesla superconducting unit using spin-echo (SE) pulse sequences. Eleven patients with pancreas head cancer were enrolled in this study. As to the lesion detectability, eight cases (73%) were detected clearly or moderately clearly on MRI, almost corresponding to 9 cases (82%) on CT. With regard to the neoplastic infiltration to the surrounding area, MRI and CT were almost equally efficient as to the capsular and the arterial invasion. However, as to the invasion to the posterion surface of pancreas and the portal system, MRI was a little superior to CT. In patients to whom foric pyrophosphate was injected, the choledochal duct was clearly separated from the tumor. In conclusion, our results suggest that MRI using abdominal belts, anticholinergic and foric pyrophosphate solution is extremely effective in the diagnosis of pancreas head cancer and is almost as efficient as CT. (author)

  7. Precise Head Tracking in Hearing Applications

    Science.gov (United States)

    Helle, A. M.; Pilinski, J.; Luhmann, T.

    2015-05-01

    The paper gives an overview about two research projects, both dealing with optical head tracking in hearing applications. As part of the project "Development of a real-time low-cost tracking system for medical and audiological problems (ELCoT)" a cost-effective single camera 3D tracking system has been developed which enables the detection of arm and head movements of human patients. Amongst others, the measuring system is designed for a new hearing test (based on the "Mainzer Kindertisch"), which analyzes the directional hearing capabilities of children in cooperation with the research project ERKI (Evaluation of acoustic sound source localization for children). As part of the research project framework "Hearing in everyday life (HALLO)" a stereo tracking system is being used for analyzing the head movement of human patients during complex acoustic events. Together with the consideration of biosignals like skin conductance the speech comprehension and listening effort of persons with reduced hearing ability, especially in situations with background noise, is evaluated. For both projects the system design, accuracy aspects and results of practical tests are discussed.

  8. Multiple Drosophila Tracking System with Heading Direction

    Directory of Open Access Journals (Sweden)

    Pudith Sirigrivatanawong

    2017-01-01

    Full Text Available Machine vision systems have been widely used for image analysis, especially that which is beyond human ability. In biology, studies of behavior help scientists to understand the relationship between sensory stimuli and animal responses. This typically requires the analysis and quantification of animal locomotion. In our work, we focus on the analysis of the locomotion of the fruit fly D r o s o p h i l a m e l a n o g a s t e r , a widely used model organism in biological research. Our system consists of two components: fly detection and tracking. Our system provides the ability to extract a group of flies as the objects of concern and furthermore determines the heading direction of each fly. As each fly moves, the system states are refined with a Kalman filter to obtain the optimal estimation. For the tracking step, combining information such as position and heading direction with assignment algorithms gives a successful tracking result. The use of heading direction increases the system efficiency when dealing with identity loss and flies swapping situations. The system can also operate with a variety of videos with different light intensities.

  9. South Africa heading for dynamic spectrum management

    CSIR Research Space (South Africa)

    Lysko, Albert A

    2016-09-01

    Full Text Available  Africa heading for dynamic spectrum management — PolicyTracker: the spectrum management newsletter https://www.policytracker.com/headlines/south­africa­heading­for­dynamic­spectrum­management/?searchterm=lysko 1/2 South Africa heading for dynamic spectrum management Sep 26, 2016 by Albert Lysko South... characteristic of rural areas, which traditionally lag behind more commercially attractive urban areas. The technology is a bridge towards fully dynamic spectrum management and 5G. The ability to manage spectrum dynamically should significantly improve the utilization and availability of spectrum, especially in rural areas, as well as...

  10. Head spray nozzle in reactor pressure vessel

    International Nuclear Information System (INIS)

    Hatano, Shun-ichi.

    1990-01-01

    In a reactor pressure vessel of a BWR type reactor, a head spray nozzle is used for cooling the head of the pressure vessel and, in view of the thermal stresses, it is desirable that cooling is applied as uniformly as possible. A conventional head spray is constituted by combining full cone type nozzles. Since the sprayed water is flown down upon water spraying and the sprayed water in the vertical direction is overlapped, the flow rate distribution has a high sharpness to form a shape as having a maximum value near the center and it is difficult to obtain a uniform flow rate distribution in the circumferential direction. Then, in the present invention, flat nozzles each having a spray water cross section of laterally long shape, having less sharpness in the circumferential distribution upon spraying water to the inner wall of the pressure vessel and having a wide angle of water spray are combined, to make the flow rate distribution of spray water uniform in the inner wall of the pressure vessel. Accordingly, the pressure vessel can be cooled uniformly and thermal stresses upon cooling can be decreased. (N.H.)

  11. Lateral head turning affects temporal memory.

    Science.gov (United States)

    Vicario, Carmelo Mario; Martino, Davide; Pavone, Enea Francesco; Fuggetta, Giorgio

    2011-08-01

    Spatial attention is a key factor in the exploration and processing of the surrounding environment, and plays a role in linking magnitudes such as space, time, and numbers. The present work evaluates whether shifting the coordinates of spatial attention through rotational head movements may affect the ability to estimate the duration of different time intervals. A computer-based implicit timing task was employed, in which participants were asked to concentrate and report verbally on colour changes of sequential stimuli displayed on a computer screen; subsequently, they were required to reproduce the temporal duration (ranging between 5 and 80 sec.) of the perceived stimuli using the computer keyboard. There was statistically significant overestimation of the 80-sec. intervals exclusively on the rightward rotation head posture, whereas head posture did not affect timing performances on shorter intervals. These findings support the hypothesis that the coordinates of spatial attention influence the ability to process time, consistent with the existence of common cortical metrics of space and time in healthy humans.

  12. Updates in Head and Neck Reconstruction.

    Science.gov (United States)

    Largo, Rene D; Garvey, Patrick B

    2018-02-01

    After reading this article, the participant should be able to: 1. Have a basic understanding of virtual planning, rapid prototype modeling, three-dimensional printing, and computer-assisted design and manufacture. 2. Understand the principles of combining virtual planning and vascular mapping. 3. Understand principles of flap choice and design in preoperative planning of free osteocutaneous flaps in mandible and midface reconstruction. 4. Discuss advantages and disadvantages of computer-assisted design and manufacture in reconstruction of advanced oncologic mandible and midface defects. Virtual planning and rapid prototype modeling are increasingly used in head and neck reconstruction with the aim of achieving superior surgical outcomes in functionally and aesthetically critical areas of the head and neck compared with conventional reconstruction. The reconstructive surgeon must be able to understand this rapidly-advancing technology, along with its advantages and disadvantages. There is no limit to the degree to which patient-specific data may be integrated into the virtual planning process. For example, vascular mapping can be incorporated into virtual planning of mandible or midface reconstruction. Representative mandible and midface cases are presented to illustrate the process of virtual planning. Although virtual planning has become helpful in head and neck reconstruction, its routine use may be limited by logistic challenges, increased acquisition costs, and limited flexibility for intraoperative modifications. Nevertheless, the authors believe that the superior functional and aesthetic results realized with virtual planning outweigh the limitations.

  13. Radionuclide patterns of femoral head disease

    Energy Technology Data Exchange (ETDEWEB)

    Webber, M M; Wagner, J; Cragin, M D [California Univ., Los Angeles (USA). Dept. of Radiological Sciences

    1977-12-01

    The pattern of uptake of bone marrow specific radio-sup(99m)Tc sulfur colloid and the pattern of uptake of bone mineral specific radio-sup(99m)Tc pryophosphate may be valuable in assessing bone vascularity in diseases suspected of causing impaired blood supply, or indicate the presence of reactive bone formation. The low energy of the technetium label has been shown to be superior to /sup 18/F and /sup 85/Sr, and leads to greater imaging detail on the scans. Femoral head scanning with mineral and/or marrow specific radionuclides offers the clinician a method of evaluating the status of the femoral head and possibly an early diagnosis of avascular necrosis before roentgenographic changes occur. This study, which reports on a 5-year experience using radionuclide scanning to assess femoral head vascularity, begins with baseline or normal studies followed by variations of the normal pattern. Typical scan patterns of hip pathology described above are also presented.

  14. Head and Neck Cancers in Developing Countries

    Directory of Open Access Journals (Sweden)

    Poonam Joshi

    2014-04-01

    Full Text Available Head and neck cancers are the most common cancers in developing countries, especially in Southeast Asia. Head and neck cancers are more common in males compared to females. This is mainly attributed to tobacco, areca nut, alcohol, etc. Oral cancers are most common amongst all head and neck squamous cell cancers (HNSCC. HNSCC in the developing world differ from those in the Western world in terms of age, site of disease, etiology, and molecular biology. Poverty, illiteracy, advanced stage at presentation, lack of access to health care, and poor treatment infrastructure pose a major challenge in management of these cancers. The annual GDP (gross domestic product spent on health care is very low in developing countries compared to the developed countries. Cancer treatment leads to a significant financial burden on the cancer patients and their families. Several health programs have been implemented to curb this rising burden of disease. The main aims of these health programs are to increase awareness among people regarding tobacco and to improve access to health care facilities, early diagnosis, treatment, and palliative care.

  15. Measurement of flow inside a vacuum cleaner head

    Science.gov (United States)

    Iguchi, Ryotaro; Ban, Hisataka; Sakakibara, Jun

    2017-11-01

    Vacuum cleaner head with rotating brushes is widely used as a home appliance. Although it efficiently collects dusts from the floor, flow field of the air and motion of the dust inside the head have not been fully investigated. In this study, we performed 3D-PIV (particle tracking velocimetry) measurement of velocity field inside the head. Water was used as working fluid, which allows a use of fluorescent particle to reduce unwanted reflection from the brushes and inner surface of the head. Mean velocity field and turbulence statistics in the head with and without the brush will be presented.

  16. Fossil plume head beneath the Arabian lithosphere?

    Science.gov (United States)

    Stein, Mordechai; Hofmann, Albrecht W.

    1992-12-01

    Phanerozoic alkali basalts from Israel, which have erupted over the past 200 Ma, have isotopic compositions similar to PREMA ("prevalent mantle") with narrow ranges of initial ɛ Nd(T) = +3.9-+5.9; 87Sr/ 86Sr(T)= 0.70292-0.70334; 206Pb/ 204Pb(T)= 18.88-19.99; 207Pb/ 204Pb(T)= 15.58-15.70; and 208Pb/ 204Pb(T)= 38.42-39.57. Their Nb/U(43 ± 9) and Ce/Pb(26 ± 6) ratios are identical to those of normal oceanic basalts, demonstrating that the basalts are essentially free of crustal contamination. Overall, the basalts are chemically and isotopically indistinguishable from many ordinary plume basalts, but no plume track can be identified. We propose that these and other, similar, magmas from the Arabian plate originated from a "fossilized" head of a mantle plume, which was unable to penetrate the continental lithosphere and was therefore trapped and stored beneath it. The plume head was emplaced some time between the late Proterozoic crust formation and the initiation of the Phanerozoic magmatic cycles. Basalts from rift environments in other continental localities show similar geochemistry to that of the Arabian basalts and their sources may also represent fossil plume heads trapped below the continents. We suggest that plume heads are, in general, characterized by the PREMA isotopic mantle signature, because the original plume sources (which may have HIMU or EM-type composition) have been diluted by overlying mantle material, which has been entrained by the plume heads during ascent. On the Arabian plate, rifting and thinning of the lithosphere caused partial melting of the stored plume, which led to periodic volcanism. In the late Cenozoic, the lithosphere broke up and the Red Sea opened. N-MORB tholeiites are now erupting in the central trough of the Red Sea, where the lithosphere has moved apart and the fossil plume has been exhausted, whereas E-MORBs are erupting in the northern and southern troughs, still tapping the plume reservoir. Fossil plumes, which are

  17. [Duodenum-preserving total pancreatic head resection and pancreatic head resection with segmental duodenostomy].

    Science.gov (United States)

    Takada, Tadahiro; Yasuda, Hideki; Nagashima, Ikuo; Amano, Hodaka; Yoshiada, Masahiro; Toyota, Naoyuki

    2003-06-01

    A duodenum-preserving pancreatic head resection (DPPHR) was first reported by Beger et al. in 1980. However, its application has been limited to chronic pancreatitis because of it is a subtotal pancreatic head resection. In 1990, we reported duodenum-preserving total pancreatic head resection (DPTPHR) in 26 cases. This opened the way for total pancreatic head resection, expanding the application of this approach to tumorigenic morbidities such as intraductal papillary mucinous tumor (IMPT), other benign tumors, and small pancreatic cancers. On the other hand, Nakao et al. reported pancreatic head resection with segmental duodenectomy (PHRSD) as an alternative pylorus-preserving pancreatoduodenectomy technique in 24 cases. Hirata et al. also reported this technique as a new pylorus-preserving pancreatoduodenostomy with increased vessel preservation. When performing DPTPHR, the surgeon should ensure adequate duodenal blood supply. Avoidance of duodenal ischemia is very important in this operation, and thus it is necessary to maintain blood flow in the posterior pancreatoduodenal artery and to preserve the mesoduodenal vessels. Postoperative pancreatic functional tests reveal that DPTPHR is superior to PPPD, including PHSRD, because the entire duodenum and duodenal integrity is very important for postoperative pancreatic function.

  18. Heading Estimation of Robot Combine Harvesters during Turning Maneuveres

    Directory of Open Access Journals (Sweden)

    Md Mostafizar Rahman

    2018-05-01

    Full Text Available Absolute heading is an important parameter for a robot combine harvester or a robot tracked combine harvester, especially while it is turning, but due to the rapid turning of robot combine harvesters, its inertial measurement unit gives a gyro measurement bias that causes heading drift. Our research goal is to estimate the absolute heading of robot combine harvesters by compensating this gyro measurement bias during non-linear turning maneuvers. A sensor fusion method like the extended Kalman filter combined with the tracked combine harvester dynamic model and sensor measurements was used to estimate the absolute heading of a robot combine harvester. Circular, sinusoidal and concave shapes were used to evaluate the estimated heading produced by the sensor fusion method. The results indicate that the estimated heading is better than measured heading which was calculated from the integration of yaw rate gyro measurements, and the root mean square errors (RMSEs for estimated headings are smaller than the measured headings. In practics, the target of this paper is thus the estimation of a heading or absolute heading that is bias compensated, and can be further used to calculate the exact crop periphery for automatic path planning of robot combine harvesters.

  19. Heading Estimation of Robot Combine Harvesters during Turning Maneuveres.

    Science.gov (United States)

    Rahman, Md Mostafizar; Ishii, Kazunobu

    2018-05-01

    Absolute heading is an important parameter for a robot combine harvester or a robot tracked combine harvester, especially while it is turning, but due to the rapid turning of robot combine harvesters, its inertial measurement unit gives a gyro measurement bias that causes heading drift. Our research goal is to estimate the absolute heading of robot combine harvesters by compensating this gyro measurement bias during non-linear turning maneuvers. A sensor fusion method like the extended Kalman filter combined with the tracked combine harvester dynamic model and sensor measurements was used to estimate the absolute heading of a robot combine harvester. Circular, sinusoidal and concave shapes were used to evaluate the estimated heading produced by the sensor fusion method. The results indicate that the estimated heading is better than measured heading which was calculated from the integration of yaw rate gyro measurements, and the root mean square errors (RMSEs) for estimated headings are smaller than the measured headings. In practics, the target of this paper is thus the estimation of a heading or absolute heading that is bias compensated, and can be further used to calculate the exact crop periphery for automatic path planning of robot combine harvesters.

  20. CT study of avascular necrosis of femoral head in adults

    International Nuclear Information System (INIS)

    Liu Jihua; Du Yuqing; Xu Aide

    2000-01-01

    Objective: To study the early and new CT signs of avascular necrosis of femoral head in adults. Methods: The CT scans of 127 cases with this condition were analyzed. Results: There were 90 hip joints with femoral head normal in shape, including 67 femoral heads with only high-density sclerosis and 23 ones with high-density and low-density areas. In 111 hip joints, the femoral head was depressed and manifested purely high-density sclerosis in 25 and mixed-density areas in 86. Air-filled cysts appeared in 43 femoral heads. In follow-up cases, the changes in shape and density of femoral head followed some rules. Conclusion: Purely high-density sclerosis is an early sign and is of great diagnostic value combined with its special shape. Air in femoral heads is also a sign of the disease

  1. Are patient specific meshes required for EIT head imaging?

    Science.gov (United States)

    Jehl, Markus; Aristovich, Kirill; Faulkner, Mayo; Holder, David

    2016-06-01

    Head imaging with electrical impedance tomography (EIT) is usually done with time-differential measurements, to reduce time-invariant modelling errors. Previous research suggested that more accurate head models improved image quality, but no thorough analysis has been done on the required accuracy. We propose a novel pipeline for creation of precise head meshes from magnetic resonance imaging and computed tomography scans, which was applied to four different heads. Voltages were simulated on all four heads for perturbations of different magnitude, haemorrhage and ischaemia, in five different positions and for three levels of instrumentation noise. Statistical analysis showed that reconstructions on the correct mesh were on average 25% better than on the other meshes. However, the stroke detection rates were not improved. We conclude that a generic head mesh is sufficient for monitoring patients for secondary strokes following head trauma.

  2. Metamerism in cephalochordates and the problem of the vertebrate head.

    Science.gov (United States)

    Onai, Takayuki; Adachi, Noritaka; Kuratani, Shigeru

    2017-01-01

    The vertebrate head characteristically exhibits a complex pattern with sense organs, brain, paired eyes and jaw muscles, and the brain case is not found in other chordates. How the extant vertebrate head has evolved remains enigmatic. Historically, there have been two conflicting views on the origin of the vertebrate head, segmental and non-segmental views. According to the segmentalists, the vertebrate head is organized as a metameric structure composed of segments equivalent to those in the trunk; a metamere in the vertebrate head was assumed to consist of a somite, a branchial arch and a set of cranial nerves, considering that the head evolved from rostral segments of amphioxus-like ancestral vertebrates. Non-segmentalists, however, considered that the vertebrate head was not segmental. In that case, the ancestral state of the vertebrate head may be non-segmented, and rostral segments in amphioxus might have been secondarily gained, or extant vertebrates might have evolved through radical modifications of amphioxus-like ancestral vertebrate head. Comparative studies of mesodermal development in amphioxus and vertebrate gastrula embryos have revealed that mesodermal gene expressions become segregated into two domains anteroposteriorly to specify the head mesoderm and trunk mesoderm only in vertebrates; in this segregation, key genes such as delta and hairy, involved in segment formation, are expressed in the trunk mesoderm, but not in the head mesoderm, strongly suggesting that the head mesoderm of extant vertebrates is not segmented. Taken together, the above finding possibly adds a new insight into the origin of the vertebrate head; the vertebrate head mesoderm would have evolved through an anteroposterior polarization of the paraxial mesoderm if the ancestral vertebrate had been amphioxus-like.

  3. Effects of Soccer Heading on Brain Structure and Function

    Science.gov (United States)

    Rodrigues, Ana Carolina; Lasmar, Rodrigo Pace; Caramelli, Paulo

    2016-01-01

    Soccer is the most popular sport in the world, with more than 265 million players worldwide, including professional and amateur ones. Soccer is unique in comparison to other sports, as it is the only sport in which participants purposely use their head to hit the ball. Heading is considered as an offensive or defensive move whereby the player’s unprotected head is used to deliberately impact the ball and direct it during play. A soccer player can be subjected to an average of 6–12 incidents of heading the ball per competitive game, where the ball reaches high velocities. Moreover, in practice sessions, heading training, which involves heading the ball repeatedly at low velocities, is common. Although the scientific community, as well as the media, has focused on the effects of concussions in contact sports, the role of subconcussive impacts, as it can occur during heading, has recently gained attention, considering that it may represent an additional mechanism of cumulative brain injury. The purpose of this study is to review the existing literature regarding the effects of soccer heading on brain structure and function. Only in the last years, some investigations have addressed the impact of heading on brain structure, by using neuroimaging techniques. Similarly, there have been some recent studies investigating biochemical markers of brain injury in soccer players. There is evidence of association between heading and abnormal brain structure, but the data are still preliminary. Also, some studies have suggested that subconcussive head impacts, as heading, could cause cognitive impairment, whereas others have not corroborated this finding. Questions persist as to whether or not heading is deleterious to cognitive functioning. Further studies, especially with longitudinal designs, are needed to clarify the clinical significance of heading as a cause of brain injury and to identify risk factors. Such investigations might contribute to the establishment of safety

  4. Effects of soccer heading on brain structure and function

    Directory of Open Access Journals (Sweden)

    Ana Carolina Oliveira Rodrigues

    2016-03-01

    Full Text Available Soccer is the most popular sport in the world, with more than 265 million players worldwide, including professional and amateur ones. Soccer is unique in comparison to other sports, as it is the only sport in which participants purposely use their head to hit the ball. Heading is considered an offensive or defensive move whereby the player’s unprotected head is used to deliberately impact the ball and direct it during play. A soccer player can be subjected to an average of six to twelve incidents of heading the ball per competitive game, where the ball reaches high velocities. Moreover, in practice sessions, heading training, which involves heading the ball repeatedly at low velocities, is common. Although the scientific community, as well as the media, has focused on the effects of concussions in contact sports, the role of subconcussive impacts, as it can occur during heading, has recently gained attention, considering that it may represent an additional mechanism of cumulative brain injury. The purpose of this study is to review the existing literature regarding the effects of soccer heading on brain structure and function. Only in the last years some investigations have addressed the impact of heading on brain structure, by using neuroimaging techniques. Similarly, there have been some recent studies investigating biochemical markers of brain injury in soccer players. There is evidence of association between heading and abnormal brain structure, but the data are still preliminary. Also, some studies have suggested that subconcussive head impacts, as heading, could cause cognitive impairment, whereas others have not corroborated this finding. Questions persist as to whether or not heading is deleterious to cognitive functioning. Further studies, especially with longitudinal designs, are needed to clarify the clinical significance of heading as a cause of brain injury and to identify risk factors. Such investigations might contribute to the

  5. The study and development of magnetic recording heads. A thin film integrated magnetic head

    International Nuclear Information System (INIS)

    Lazzari, Jean-Pierre

    1970-01-01

    A new integrated magnetic head is described. The head was made by vacuum deposition using a mask. A magnetically coupled multilayer construction led to high performance. The results obtained indicate that the device functions equally well, for reading and writing. A set of calculations was developed which could simulate and optimize the behavior of the recording head. The results obtained with the writing were in good agreement with those obtained from experiments and quite different from results which have been several times previously published. In addition a new method was developed for measuring high fields in confined spaces; a 1000 A diameter probe was used in conjunction with a low angle diffraction procedure. The measurements give results which are very different from those obtained by current theories based on the magnetic potentials at the surface. (author) [fr

  6. Head-up and head-down displays integration in automobiles

    Science.gov (United States)

    Betancur, J. Alejandro; Osorio-Gómez, Gilberto; Agudelo, J. David

    2014-06-01

    In automotive industry, the dashboard has been ergonomically developed in order to keep the driver focused on the horizon while driving, but the possibility to access external electronic devices constraints the driver to turn away his face, generating dangerous situations in spite of the short periods of time. Therefore, this work explores the integration of Head-Up Displays and Head-Down Displays in automobiles, proposing configurations that give to drivers the facility to driving focused. In this way, some of the main ergonomic comments about those configurations are proposed; and also, some technical comments regarding the implemented arrangements are given.

  7. Advances and trends of head-up and head-down display systems in automobiles

    Science.gov (United States)

    Betancur, J. Alejandro; Osorio-Gomez, Gilberto; Agudelo, J. David

    2014-06-01

    Currently, in the automotive industry the interaction between drivers and Augmented Reality (AR) systems is a subject of analysis, especially the identification of advantages and risks that this kind of interaction represents. Consequently, this paper attempts to put in evidence the potential applications of Head-Up (Display (HUD) and Head-Down Display (HDD) systems in automotive vehicles, showing applications and trends under study. In general, automotive advances related to AR devices suggest the partial integration of the HUD and HDD in automobiles; however, the right way to do it is still a moot point.

  8. Averaging hydraulic head, pressure head, and gravitational head in subsurface hydrology, and implications for averaged fluxes, and hydraulic conductivity

    Directory of Open Access Journals (Sweden)

    G. H. de Rooij

    2009-07-01

    Full Text Available Current theories for water flow in porous media are valid for scales much smaller than those at which problem of public interest manifest themselves. This provides a drive for upscaled flow equations with their associated upscaled parameters. Upscaling is often achieved through volume averaging, but the solution to the resulting closure problem imposes severe restrictions to the flow conditions that limit the practical applicability. Here, the derivation of a closed expression of the effective hydraulic conductivity is forfeited to circumvent the closure problem. Thus, more limited but practical results can be derived. At the Representative Elementary Volume scale and larger scales, the gravitational potential and fluid pressure are treated as additive potentials. The necessary requirement that the superposition be maintained across scales is combined with conservation of energy during volume integration to establish consistent upscaling equations for the various heads. The power of these upscaling equations is demonstrated by the derivation of upscaled water content-matric head relationships and the resolution of an apparent paradox reported in the literature that is shown to have arisen from a violation of the superposition principle. Applying the upscaling procedure to Darcy's Law leads to the general definition of an upscaled hydraulic conductivity. By examining this definition in detail for porous media with different degrees of heterogeneity, a series of criteria is derived that must be satisfied for Darcy's Law to remain valid at a larger scale.

  9. Bird-Headed Dwarf of Seckel

    Directory of Open Access Journals (Sweden)

    Harsha Vardhan B

    2007-05-01

    Full Text Available Seckel syndrome is an extremely rare inherited disorder characterized by growth delays prior to birth resulting in low birth weight. Growth delays continue after birth resulting in short stature (dwarfism. This syndrome is associated with an abnormally small head, varying degrees of mental retardation and unusual "beak like" protrusion of nose. Other facial features may include abnormally large eyes, a narrow face, malformed ears and an unusually small jaw. This syndrome has an autosomal recessive pattern of inheritance. A case of the Seckel syndrome is presented.

  10. Head first iPhone development

    CERN Document Server

    Pilone, Dan

    2010-01-01

    Let's say you have an idea for a killer iPhone app. Where do you begin? Head First iPhone Development will help you get your first application up and running in no time. You'll quickly learn to use iPhone SDK tools, including Interface Builder and Xcode, and master Objective-C programming principles that will make your app stand out. It's a complete learning experience for creating eye-catching, top-selling iPhone applications. Put Objective-C core concepts to work, including message passing, protocols, properties, and memory managementTake advantage of iPhone patterns such as datasources

  11. Writing otorhinolaryngology head & neck surgery operative reports.

    Science.gov (United States)

    Laccourreye, O; Rubin, F; Villeneuve, A; Bonfils, P

    2017-09-01

    Only about ten articles devoted to operative reports have been published in the medical literature, but this document is essential, both medically and legally, to ensure optimal management of operated patients. In this technical note, based on published studies on this subject, the authors describe the key features of operating reports after otorhinolaryngology head & neck surgery and emphasize the need to write this document during the minutes after the end of the operation, the importance of standardization and its teaching role during surgical training. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  12. Uranium enrichment: heading for the abyss

    International Nuclear Information System (INIS)

    Norman, C.

    1983-01-01

    This article discusses the federal government's $2.3 billion a year business enriching uranium for nuclear power plants which is heading toward a major crisis. Due to miscalculations by the Department of Energy, it is caught with billions of dollars of construction in progress just as projected demand for enriched uranium is decreasing. At the center of the controversy is the Gas Centrifuge Plant at Portsmouth, Ohio - estimated to cost $10 billion dollars. A review of how DOE got into this situation and how they plan to solve it is presented

  13. diagnostic imaging of acute head trauma

    International Nuclear Information System (INIS)

    Prayer, D.; Rametsteiner, C.

    2001-01-01

    Computed tomography (CT) is the primary modality of choice for imaging patients with acute head trauma. Lesions of the soft tissues and of the bones can be assessed more precisely than with other imaging modalities. With magnetic resonance imaging (MRI) additional information may be gained especially in subacute and chronic posttraumatic conditions. Urgent indication to perform a CT examination depends on the patient's history and on the mechanism of trauma. Imaging interpretation has been performed in the context of typical pathologic effects of trauma and with respect to potential therapy. (author)

  14. Leadership styles in ethical dilemmas when head nurses make decisions.

    Science.gov (United States)

    Zydziunaite, V; Lepaite, D; Suominen, T

    2013-06-01

    The overlooked aspect in Lithuania is the dearth of leaders among head nurses, who bear the responsibility for decisions in ethical dilemmas. Understanding the application of leadership styles is fundamental to ensuring head nurses' abilities to influence outcomes for healthcare providers and patients. To identify the leadership styles applied by head nurses in decision making in ethical dilemmas on hospital wards. The data were collected by questionnaires completed by head nurses (n = 278) working in five major state-funded hospitals in each of the five regions of Lithuania. The data were analysed using SPSS 16.0, calculating descriptive statistics and analysis of variance. Head nurses apply democratic, affiliative, transformational and sustainable leadership styles when resolving ethical dilemmas. The application of leadership styles is associated not only with specific situations, but also with certain background factors, such as years of experience in a head nurse's position, ward specialization and the incidence of ethical dilemmas. Nurses having been in a head nurse's position over 10 years use primitive leadership styles, notably bureaucratic leadership, more often than do those head nurses with only a few years of experience in such a position. The results highlight the need for head nurses to reflect on their practices and to find new ways of learning from practice, colleagues and patients. Head nurses' managerial decisions due to their 'executive power' can turn into a new state-of-the-art leadership in nursing. © 2013 The Authors. International Nursing Review © 2013 International Council of Nurses.

  15. [The family. The poorest households with female heads].

    Science.gov (United States)

    Acosta Diaz, F

    1992-01-01

    Data from the household questionnaire of the 1987 Mexican Fertility and Health Survey were the basis for an analysis of the characteristics of households headed by women. 14.1% of households were headed by women in 1987, of which 14% were in rural and 86% in urban areas. 41.9% of the households headed by women contained only a woman and her children. Child care responsibilities are the main determinant of discrimination in the labor market for these women and oblige them to accept jobs that are not adequately paid. The social disadvantage of households headed by women is also related to their age and marital and educational status. Among male and female household heads respectively, 16.3% and 36.5% were over age 60, 16.4% and 27.5% were illiterate, and 92.7% and 8.4% were married or in union. 15.5% of the female heads were single, 24.7% were divorced or separated, and 51.4% were widows. Among employed female household heads, 49.2% were salaried, 36.5% were self-employed, and 10.1% were domestic workers. 63.8% of female and 46.3% of male household heads earned one minimum salary or less per month. The average size of households headed by women was 3.9 members, compared to 5.4 for households headed by men.

  16. [Abnormal head turn in a patient with Brown's syndrome].

    Science.gov (United States)

    van Waveren, M; Krzizok, T; Besch, D

    2008-08-01

    We report on an eight-year-old boy, who was presented in our clinic because of head turn. The cause of the tortecollis (ocular or general) in this case was and still cannot be explained. Only by applying extensive prism adaptation tests it was possible to prove the ocular character of the head turn. An eight-year-old boy with Brown's syndrome was referred to us because of a head tilt to the left side. Six months previously surgery on the M. obl. superior of the right eye was performed in another clinic. No improvement of the head tilt could be observed after the operation. In addition, an exotropia became decompensated. Under a 3-day occlusion of one eye, no change of the head turn and the squint could be measured. No other cause of the head turn could be found by an orthopaedist and a paediatrist. Under a prism of 20 cm/m basis in and 10 cm/m basis against the positive vertical deviation, the head tilt decreased, so that we decided to do a second surgery. The head tilting had not resumed at one year after the surgery. Although the initial diagnostic findings ruled out an ocular cause, it was possible to lessen the head tilting with the aid of the prism adaptation test. This case study emphasises the usefulness of a prism adaptation test of several days duration in order to validate an ocular cause of head turn and to determine an adequate indication for surgery.

  17. Manual of head and neck imaging

    International Nuclear Information System (INIS)

    Raghavan, Prashant; Mukherjee, Sugoto; Jameson, Mark J.; Wintermark, Max

    2014-01-01

    Easy-to-read short chapters. Tables, checklists, and algorithms to assist in arriving at a quick diagnosis. Clinical pearls that will enable the radiologist to issue a relevant report. One-stop resource when preparing for radiology and otolaryngology exams. Line diagrams to illustrate key concepts. This book is designed as an easily readable manual that will be of great practical value for radiology and otolaryngology residents during their clinical rotations. Key facts on head and neck imaging are presented in short chapters written in an easily readable style. Line drawings are used to illustrate key concepts, and tables, checklists, and algorithms will enable the readers to arrive at a quick diagnosis. In addition, emphasis is placed on clinical pearls that will assist them in preparing suitable reports. The Manual of Head and Neck Imaging is sized to allow residents to read it completely within a matter of days, and it will also serve as an ideal quick reference guide as different clinical situations arise.

  18. New Head of the Users Office

    CERN Multimedia

    Anaïs Schaeffer

    2011-01-01

    Doris Chromek-Burckhart took over as Head of the Users Office on 1 June. She succeeds Chris Onions, who held the post for more than ten years before retiring in 2010, and Jose Salicio Diez, who replaced him temporarily.   Doris Chromek-Burckhart photographed by Pierre Gildemyn. Doris Chromek-Burckhart arrived at CERN about thirty years ago after completing a physics degree at Mainz University in Germany, and began her career with the Organization working on data acquisition systems for the experiments. She then joined ATLAS, where she took part in the development, commissioning and operation of the experiment's own data acquisition system. Her appointment as Head of the Users Office was preceded by two years as CERN's Equal Opportunities Officer from 2009 to 2010. The Users Office, which has now been in existence for over twenty years, manages administrative procedures and generally makes life easier for the 10,000 or more users from around a hundred different countries, in collaboration with CER...

  19. CT analysis of missile head injury

    International Nuclear Information System (INIS)

    Besenski, N.; Jadro-Santel, D.; Jelavic-Koic, F.; Pavic, D.; Mikulic, D.; Glavina, K.; Maskovic, J.

    1995-01-01

    Between August 1991 and December 1992, CT was performed in 154 patients who had suffered missile head injury during the war in the Republic of Croatia. In 54% CT was performed 1-24 h after injury, and in 27% follow-up CT was also obtained. The wounds were penetrating, tangential or perforating (45%, 34% and 21%, respectively). Haemorrhage was the most frequent lesion in the brain (84%). Follow-up CT evolution of haemorrhage, oedema, cerebritis, abscess, secondary vascular lesions, necrosis, encephalomalacia and hydrocephalus. The most dynamic changes occurred 7-14 days after injury. In 14% of cases, deep cerebral lesions were found in the corpus callosum, septum pellucidum periventricular region and pons, although bone and shell fragments were in a different part of the brain parenchyma. Such lesions were found in penetrating injuries only. CT proved very useful for assessing the extent and type of lesions. Although different mechanisms of brain damage in missile head injury are known, here they are, to the best of our knowledge, shown for the first time by CT. (orig.)

  20. Postmortem CT of severe head injuries

    International Nuclear Information System (INIS)

    Tamura, Masaru; Tsukahara, Yoshio; Nagaseki, Yoshishige; Horikoshi, Satoru; Yodonawa, Masahiko

    1983-01-01

    CT findings of fatal head injuries were analysed for the cause of death. Postmortem CT examinations were undertaken on 14 cases who died before reaching the hospital or shortly after arrival at the hospital (immediate death group). CT were also examined in non-operative 20 cases who were comatose and who died within 24 hours after severe head injuries (early death group). In the immediate death group, the following findings were demonstrated: a huge amount of free intracranial and intraventricular air in 8 cases; traumatic basal subarachnoid hemorrhage in 3 cases; a mixture of pneumocephalus and subarachnoid hemorrhage in 2 cases, and intracranial hematoma in 1 case. In the early death group: a mixture of pneumocephalus and subarachnoid hemorrhage in 2 cases; traumatic subarachnoid hemorrhage in 5 cases; intracranial hematoma in 11 cases, and brain contusion in 2 cases. The huge amount of intracranial free air due to the severe fracture of the skull base will make the CNS collapse immediately. Basal subarachnoid hemorrhage with signs of brain-stem injuries may result in instantaneous death. Acute subdural hematoma with contusion and edema in elderly patients was the most frequent cause of death in the early death group. (author)