  1. Cyberknife stereotactic treatment

    International Nuclear Information System (INIS)

    Lief, Eugene

    2008-01-01

    The topic discussed included, among others, the following: cyberknife capabilities; autonomous robotics; continuous image guidance; flexible robotics maneuverability; Dynamic motion targeting; intelligent patient positioning; 4D treatment optimization and planning system; X-ray sources; robotic manipulator; linear accelerator; MultiPlan treatment planning system; radiosurgery vs radiotherapy; radiation system delivery comparison; simplified contouring; plan optimization; QA and commissioning. (P.A.)

  2. SU-E-T-395: Evaluation of Multiple Brain Metastases Stereotactic Treatment Planning in Cyberknife Versus Linac

    International Nuclear Information System (INIS)

    Vikraman, S; Rajesh, Thiyagarajan; Karrthick, Kp; Sambasivaselli, R; Senniandavar, V; Ramu, M; Maragathaveni, S; Dhivya, N; Tejinder, K; Manigandan, D; Muthukumaran, M

    2015-01-01

    Purpose: The purpose of this study was to evaluate multiple brain metastases stereotactic treatment planning of Cyberknife versus linac using dose volume based indices. Methods: Fifteen multiple brain metastases patients were taken for this study from Cyberknife Multiplan TPSv4.6.0. All these patients underwent stereotactic treatment in Cyberknife. For each patient VMAT stereotactic treatment plan was generated in MONACO TPSv5.0 using Elekta beam modulator MLC and matched the delivered plan. A median dose of 8.5Gy(range 7–12Gy) per fraction was prescribed. Tumor volume was in the range of 0.06–4.33cc. Treatment plan quality was critically evaluated by comparing DVH indices such as D98, D95, CI, and HI for target volumes. Maximum point doses and volume doses were evaluated for critical organs. Results: For each case, target coverage of D98 was achieved with 100% prescription dose with SD of 0.29% and 0.41% in Linac and Cyberknife respectively. The average conformity index(CI) of 1.26±0.0796 SD for Cyberknife and 1.92±0.60SD for linac were observed. Better homogeneity Index (HI) of 1.17±0.09SD was observed in linac as compared to Cyberknife HI of 1.24±0.05SD.All the critical organ doses were well within tolerance limit in both linac and Cyberknife plans. There is no significant difference of maximum point doses for brainstem and optic chiasm. Treatment time and number of monitor units are more in Cyberknife compared to linac. The average volume receiving 12Gy in whole brain was 6% and 12% for Cyberknife and linac respectively. 1000cc of whole brain received 60% lesser dose in Linac compared to Cyberknife in all cases. Conclusion: The study shows that dosimetrically comparable plans are achievable Cyberknife and Linac. However, a better conformity, target coverage, lesser OAR dose is achieved with Cyberknife due to greater degrees of freedom with robotic gantry and smaller collimator for multiple targets

  3. Accuracy of out-of-field dose calculation of tomotherapy and Cyberknife treatment planning systems. A dosimetric study

    International Nuclear Information System (INIS)

    Schneider, Uwe; Hirslanden Medical Center, Aarau; Haelg, Roger A.; Hartmann, Matthias; Mack, Andreas; Storelli, Fabrizio; Besserer, Juergen; Joosten, Andreas; Moeckli, Raphael

    2014-01-01

    Purpose: Late toxicities such as second cancer induction become more important as treatment outcome improves. Often the dose distribution calculated with a commercial treatment planning system (TPS) is used to estimate radiation carcinogenesis for the radiotherapy patient. However, for locations beyond the treatment field borders, the accuracy is not well known. The aim of this study was to perform detailed out-of-field-measurements for a typical radiotherapy treatment plan administered with a Cyberknife and a Tomotherapy machine and to compare the measurements to the predictions of the TPS. Materials and methods: Individually calibrated thermoluminescent dosimeters were used to measure absorbed dose in an anthropomorphic phantom at 184 locations. The measured dose distributions from 6 MV intensity-modulated treatment beams for CyberKnife and TomoTherapy machines were compared to the dose calculations from the TPS. Results: The TPS are underestimating the dose far away from the target volume. Quantitatively the Cyberknife underestimates the dose at 40 cm from the PTV border by a factor of 60, the Tomotherapy TPS by a factor of two. If a 50% dose uncertainty is accepted, the Cyberknife TPS can predict doses down to approximately 10 mGy/treatment Gy, the Tomotherapy-TPS down to 0.75 mGy/treatment Gy. The Cyberknife TPS can then be used up to 10 cm from the PTV border the Tomotherapy up to 35 cm. Conclusions: We determined that the Cyberknife and Tomotherapy TPS underestimate substantially the doses far away from the treated volume. It is recommended not to use out-of-field doses from the Cyberknife TPS for applications like modeling of second cancer induction. The Tomotherapy TPS can be used up to 35 cm from the PTV border (for a 390 cm 3 large PTV). (orig.)

  4. Clinical experience with image-guided robotic radiosurgery (the Cyberknife) in the treatment of brain and spinal cord tumors

    International Nuclear Information System (INIS)

    Chang, S.D.; Murphy, M.; Geis, P.; Martin, D.P.; Hancock, S.L.; Doty, J.R.; Adler, J.R. Jr.

    1998-01-01

    The Cyberknife is an image-guided ''frameless'' dedicated radiosurgical device. This instrument has several distinct advantages over frame-based systems, including improved patient comfort, increased treatment degrees of freedom, and the potential to target extracranial lesions. Clinical results thus far with respect to the treatment of malignant intracranial tumors has been promising. Additionally, the Cyberknife will likely revolutionize the application of radiosurgery to extracranial sites. A description of the components, treatment planning, and clinical results of the Cyberknife will be reviewed. (author)

  5. SU-F-SPS-10: The Dosimetric Comparison of GammaKnife and Cyberknife Treatment Plans for Brain SRS Treatment

    International Nuclear Information System (INIS)

    Sanli, E; Mabhouti, H; Cebe, M; Codel, G; Pacaci, P; Serin, E; Kucuk, N; Kucukmorkoc, E; Doyuran, M; Canoglu, D; Altinok, A; Acar, H; Caglar Ozkok, H

    2016-01-01

    Purpose: Brain stereotactic radiosurgery (SRS) involves the use of precisely directed, single session radiation to create a desired radiobiologic response within the brain target with acceptable minimal effects on surrounding structures or tissues. In this study, the dosimetric comparison of GammaKnife perfection and Cyberknife M6 treatment plans were made. Methods: Treatment plannings were done for GammaKnife perfection unit using Gammaplan treatment planning system (TPS) on the CT scan of head and neck randophantom simulating the treatment of sterotactic treatments for one brain metastasis. The dose distribution were calculated using TMR 10 algorithm. The treatment planning for the same target were also done for Cyberknife M6 machine using Multiplan (TPS) with Monte Carlo algorithm. Using the same film batch, the net OD to dose calibration curve was obtained using both machine by delivering 0- 800 cGy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. Dose distribution were measured using EBT3 film dosimeter. The measured and calculated doses were compared. Results: The dose distribution in the target and 2 cm beyond the target edge were calculated on TPSs and measured using EBT3 film. For cyberknife treatment plans, the gamma analysis passing rates between measured and calculated dose distributions were 99.2% and 96.7% for target and peripheral region of target respectively. For gammaknife treatment plans, the gamma analysis passing rates were 98.9% and 93.2% for target and peripheral region of target respectively. Conclusion: The study shows that dosimetrically comparable plans are achievable with Cyberknife and GammaKnife. Although TMR 10 algorithm predicts the target dose

  6. SU-F-SPS-10: The Dosimetric Comparison of GammaKnife and Cyberknife Treatment Plans for Brain SRS Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Sanli, E; Mabhouti, H; Cebe, M; Codel, G; Pacaci, P; Serin, E; Kucuk, N; Kucukmorkoc, E; Doyuran, M; Canoglu, D; Altinok, A; Acar, H; Caglar Ozkok, H [Medipol University, Istanbul, Istanbul (Turkey)

    2016-06-15

    Purpose: Brain stereotactic radiosurgery (SRS) involves the use of precisely directed, single session radiation to create a desired radiobiologic response within the brain target with acceptable minimal effects on surrounding structures or tissues. In this study, the dosimetric comparison of GammaKnife perfection and Cyberknife M6 treatment plans were made. Methods: Treatment plannings were done for GammaKnife perfection unit using Gammaplan treatment planning system (TPS) on the CT scan of head and neck randophantom simulating the treatment of sterotactic treatments for one brain metastasis. The dose distribution were calculated using TMR 10 algorithm. The treatment planning for the same target were also done for Cyberknife M6 machine using Multiplan (TPS) with Monte Carlo algorithm. Using the same film batch, the net OD to dose calibration curve was obtained using both machine by delivering 0- 800 cGy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. Dose distribution were measured using EBT3 film dosimeter. The measured and calculated doses were compared. Results: The dose distribution in the target and 2 cm beyond the target edge were calculated on TPSs and measured using EBT3 film. For cyberknife treatment plans, the gamma analysis passing rates between measured and calculated dose distributions were 99.2% and 96.7% for target and peripheral region of target respectively. For gammaknife treatment plans, the gamma analysis passing rates were 98.9% and 93.2% for target and peripheral region of target respectively. Conclusion: The study shows that dosimetrically comparable plans are achievable with Cyberknife and GammaKnife. Although TMR 10 algorithm predicts the target dose.

  7. Treat high cervical spinal arteriovenous malformation with Cyberknife radiosurgery

    Directory of Open Access Journals (Sweden)

    Yu-Fen Huang

    2014-01-01

    Full Text Available This paper describes the use of CyberKnife radiosurgery in the treatment of accidentally found cervical spinal arteriovenous malformation (AVM. We present the case of a patient with cervical spinal AVM, who developed progressive neck pain, gait disturbance, urine and stool incontinence 2 weeks after the fell down accident. The patient underwent CyberKnife radiosurgery. After CyberKnife radiosurgery for 2 years, the patient′s neck pain diminished and was able to keep the walk without any assistance. The management of cervical spinal AVM varies. This patient demonstrated a successful treatment of cervical spinal AVM with CyberKnife radiosurgery.

  8. An initial report of cyberknife radiosurgery treatment in early stage lung cancer

    International Nuclear Information System (INIS)

    Yuan Zhiyong; Song Yongchun; Li Fengtong; Dong Yang; Wang Jingsheng; Wang Jun; Wang Changli; Wang Ping

    2008-01-01

    Objective: To study the efficacy and toxicity of the cyberknife in the treatment of medically inoperable patients with early stage lung cancer. Methods: From September 2006 to July 2007,17 patients with clinical stage I a-I b lung cancer were treated with cyberknife at Tianjin Cancer Hospital. Of the 11 patients receiving CT guided biopsy, 3 were squamous cell cancer and 8 were adenocarcinoma. Six patients refused intrusive operation and were diagnosed by PET-CT scan. All patients were medically inoperable evaluated by a thoracic surgeon. The PTV=GTV + 3-5 mm, and the median volume of PTV was 36 cm 3 (6-82 cm 3 ). The median total prescription dose was 50 Gy(45-60 Gy) at 3-5 fractions. Results: The median follow-up time was 7 months(3-11 months). All the patients finished the treatment and were alive by the last follow-up. Slight fatigue was the most common complain. Evaluated by CT scan, 13 were complete response and 4 were partial response. No recurrence, progression or distant metastasis occurred. There were 3 patients with grade I granulocytopenia, 3 grade I pneumonitis and 1 grade II pneumonitis. Conclusions: The cyberknife radiosurgery treatment in early stage lung cancer shows a high rate of local control and minimal toxicity. Long time follow-up is necessary to evaluate the survival data and late toxicity. (authors)

  9. Robotic radiotherapy for prostate cancer with CyberKnife

    International Nuclear Information System (INIS)

    Hannoun-Levi, J.M.; Benezery, K.; Bondiau, P.Y.; Marcie, S.; Gerard, J.P.; Chamorey, E.

    2007-01-01

    After 3D conformal radiation therapy without and with modulated intensity, image-guided radiation therapy represents a new technological step. Should prostate cancer treatment using radiotherapy with the CyberKnife robotic system be considered as a new treatment and then investigated through classical clinical research procedure rather than a technical improvement of an already validated treatment? After a general presentation of the CyberKnife, the authors focused on prostate cancer treatment assuming that, according to dosimetric and biological considerations, the treatment by robotic system appears comparable to high dose rate brachytherapy. For prostate cancer treatment are discussed: biological rational for hypo fractionated treatment, high dose rate brachytherapy boost and interest of dose escalation. A comparison is presented between CyberKnife and other validated treatment for prostate cancer (radical prostatectomy, 3D conformal radiation therapy and low and high dose rate brachytherapy). In summary, CyberKnife treatment could be considered as a technical improvement of an already validated treatment in order to deliver a prostate boost after pelvic or peri-prostatic area irradiation. However, the clinical, biological and economical results must be precisely analyzed and could be assessed in the frame of a National Observatory based on shared therapeutic program. (authors)

  10. A new strategy of CyberKnife treatment system based radiosurgery followed by early use of adjuvant bevacizumab treatment for brain metastasis with extensive cerebral edema.

    Science.gov (United States)

    Wang, Yang; Wang, Enmin; Pan, Li; Dai, Jiazhong; Zhang, Nan; Wang, Xin; Liu, Xiaoxia; Mei, Guanghai; Sheng, Xiaofang

    2014-09-01

    Bevacizumab blocks the effects of vascular endothelial growth factor in leakage-prone capillaries and has been suggested as a new treatment for cerebral radiation edema and necrosis. CyberKnife is a new, frameless stereotactic radiosurgery system. This work investigated the safety and efficacy of CyberKnife followed by early bevacizumab treatment for brain metastasis with extensive cerebral edema. The eligibility criteria of the patients selected for radiosurgery followed by early use of adjuvant bevacizumab treatment were: (1) brain tumors from metastasis with one solitary brain lesion and symptomatic extensive cerebral edema; (2) >18 years of age; (3) the patient refused surgery due to the physical conditions and the risk of surgery; (4) no contraindications for bevacizumab. (5) bevacizumab was applied for a minimum of 2 injections and a maximum of 6 injections with a 2-week interval between treatments, beginning within 2 weeks of the CyberKnife therapy; (6) Karnofsky performance status (KPS) ≥30. Tumor size and edema were monitored by magnetic resonance imaging (MRI). Dexamethasone dosage, KPS, adverse event occurrence and associated clinical outcomes were also recorded. Eight patients were accrued for this new treatment. Radiation dose ranged from 20 to 33 Gy in one to five sessions, prescribed to the 61-71 % isodose line. Bevacizumab therapy was administered 3-10 days after completion of CyberKnife treatment for a minimum of two cycles (5 mg/kg, at 2-week intervals). MRI revealed average reductions of 55.8 % (post-gadolinium) and 63.4 % (T2/FLAIR). Seven patients showed significant clinical neurological improvements. Dexamethasone was reduced in all patients, with five successfully discontinuing dexamethasone treatment 4 weeks after bevacizumab initiation. Hypertension, a bevacizumab-related adverse event, occurred in one patient. After 3-8 months, all patients studied were alive and primary brain metastases were under control, 2 developed new brain

  11. Quality level of a treatment by Cyberknife with Synchrony; Niveau de qualite d'un traitement par le CyberKnife avec Synchrony

    Energy Technology Data Exchange (ETDEWEB)

    Khawaja, M.S.A.; Noel, A. [CRAN UMR 7039, CNRS, 54 - Vandoeuvre-les-Nancy (France); Centre Alexis-Vautrin, 54 - Vandoeuvre-les-Nancy (France); Nancy-1 Univ., 54 (France); Marchesi, V. [Centre Alexis-Vautrin, 54 - Vandoeuvre-les-Nancy (France); Wolf, D. [INPL CRAN UMR 7039, CNRS, 54 - Vandoeuvre-les-Nancy (France)

    2009-10-15

    The Cyberknife and its Synchrony associated subsystem represent a very reliable mean to treat the tumors of soft tissues moving with respiration. It allows to guarantee a high quality of treatment because of sub-millimetric accuracy whatever be the complexity degree of the patient respiration cycle. (N.C.)

  12. Initial results of CyberKnife treatment for recurrent previously irradiated head and neck cancer

    International Nuclear Information System (INIS)

    Himei, Kengo; Katsui, Kuniaki; Yoshida, Atsushi

    2003-01-01

    The purpose of this study was to evaluate the efficacy of CyberKnife for recurrent previously irradiated head and neck cancer. Thirty-one patients with recurrent previously irradiated head and neck cancer were treated with a CyberKnife from July 1999 to March 2002 at Okayama Kyokuto Hospital were retrospectively studied. The accumulated dose was 28-80 Gy (median 60 Gy). The interval between CyberKnife treatment and previous radiotherapy was 0.4-429.5 months (median 16.3 months). Primary lesions were nasopharynx: 7, maxillary sinus: 6, tongue: 5, ethmoid sinus: 3, and others: 1. The pathology was squamous cell carcinoma: 25, adenoid cystic carcinoma: 4, and others: 2. Symptoms were pain: 8, and nasal bleeding: 2. The prescribed dose was 15.0-40.3 Gy (median 32.3 Gy) as for the marginal dose. The response rate (complete response (CR)+partial response (PR)) and local control rate (CR+PR+no change (NC)) was 74% and 94% respectively. Pain disappeared for 4 cases, relief was obtained for 4 cases and no change for 2 cases and nasal bleeding disappeared for 2 cases for an improvement of symptoms. An adverse effects were observed as mucositis in 5 cases and neck swelling in one case. Prognosis of recurrent previously irradiated head and neck cancer was estimated as poor. Our early experience shows that CyberKnife is expected to be feasible treatment for recurrent previously irradiated head and neck cancer, and for the reduction adverse effects and maintenance of useful quality of life (QOL) for patients. (author)

  13. Fractionated stereotactic irradiation by Cyberknife of choroid melanomas: repositioning validation, closed eyelids; Irradiation stereotaxique fractionnee par Cyberknife des melanomes choroidiens: validation du repositionnement, paupieres fermees

    Energy Technology Data Exchange (ETDEWEB)

    Horn, S.; Rezvoy, N.; Lacornerie, T.; Mirabel, X.; Labalette, P.; Lartigau, E. [Centre Oscar-Lambret, Service de Radiotherapie, 59 - Lille (France)

    2009-10-15

    The fractionated stereotactic radiotherapy by Cyberknife is an option in the treatment of eyes tumors. The advantages of the Cyberknife in the choroid melanomas are in its infra-millimetric precision, to the automated repositioning on the skull bones and to the conformity brought by the stereotaxy. The objective of this study was to validate the quality of repositioning and the immobility of the eyes with closed eyelids. Conclusion: the reproducibility of the eye positioning with closed eyelids seems enough to consider the conservative treatment of choroid melanomas by fractionated stereotactic radiotherapy by Cyberknife without implementation of fiducials nor retrobulbar anaesthesia. (N.C.)

  14. SU-F-T-538: CyberKnife with MLC for Treatment of Large Volume Tumors: A Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Bichay, T; Mayville, A [Mercy Health, Saint Mary’s, Grand Rapids, MI (United States)

    2016-06-15

    Purpose: CyberKnife is a well-documented modality for SRS and SBRT treatments. Typical tumors are small and 1–5 fractions are usually used. We determined the feasibility of using CyberKnife, with an InCise multileaf collimator option, for larger tumors undergoing standard dose and fractionation. The intent was to understand the limitation of using this modality for other external beam radiation treatments. Methods: Five tumors from different anatomical sites with volumes from 127.8 cc to 1,320.5 cc were contoured and planned on a Multiplan V5.1 workstation. The target average diameter ranged from 7 cm to 13 cm. The dose fractionation was 1.8–2.0 Gy/fraction and 25–45 fractions for total doses of 45–81 Gy. The sites planned were: pancreas, head and neck, prostate, anal, and esophagus. The plans were optimized to meet conventional dose constraints based on various RTOG protocols for conventional fractionation. Results: The Multiplan treatment planning system successfully generated clinically acceptable plans for all sites studied. The resulting dose distributions achieved reasonable target coverage, all greater than 95%, and satisfactory normal tissue sparing. Treatment times ranged from 9 minutes to 38 minutes, the longest being a head and neck plan with dual targets receiving different doses and with multiple adjacent critical structures. Conclusion: CyberKnife, with the InCise multileaf collimation option, can achieve acceptable dose distributions in large volume tumors treated with conventional dose and fractionation. Although treatment times are greater than conventional accelerator time; target coverage and dose to critical structures can be kept within a clinically acceptable range. While time limitations exist, when necessary CyberKnife can provide an alternative to traditional treatment modalities for large volume tumors.

  15. CyberKnife radiosurgery: Precision without incision

    Directory of Open Access Journals (Sweden)

    Enja Siva Prasad Reddy

    2015-01-01

    Full Text Available CyberKnife stereotactic radiosurgery system is an innovative, effective, frameless, non-invasive substitute for conventional surgical treatment of cancer. It works on the principle of stereotaxy. It is used for the treatment of both cancerous and non-cancerous tumors, intracranial lesions, tumors of lung, spine, prostate, and kidney, recurrent cases of oral squamous cell carcinoma, arteriovenous malformation, and trigeminal neuralgia. It has an advantage over other systems like Gamma knife radiosurgery and linear accelerator (LINAC-based systems, as it is frameless, has submillimeter accuracy, does not affect the normal cells adjacent to the lesion, and tracks the lesion in synchronization with the patient′s respiratory rate. The future of CyberKnife encompasses possibilities such as incremental improvements in accuracy and better shaping of the field of radiation and would certainly allow extension of radiosurgery as an effective substitute for chemotherapy. This paper aims to review and highlight the immense potential that CyberKnife holds in the field of dentistry in treating disorders of the head and neck region, thereby ensuring enhanced longevity for the patients.

  16. SU-F-T-633: Cyberknife Boost Versus Conventional Tandem and Ovoid Treatment for Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Santoro, J; Witten, M; Haas, J [Winthrop University Hospital, Lynbrook, NY (United States)

    2016-06-15

    Purpose: Brachytherapy has been the standard of care for cervical cancer for 100 years. The treatment can be administered using an HDR (high dose rate) remote afterloader with a {sup 192}Ir source in an outpatient setting, a PDR afterloader with a {sup 192}Ir source, or with LDR manually loaded or a remote afterloader utilizing {sup 192}Ir or {sup 137}Cs sources in an inpatient setting. The procedure involves the placement of a tandem and ovoid, tandem and ring, or tandem and cylinder applicator in an operating room setting with the patient under general anesthesia. Inaccuracies introduced into the process occurring between placement of the applicator and actual delivery can introduce uncertainty into the actual dose delivered to the tumor and critical organs. In this study we seek to investigate the dosimetric difference between an SBRT-based radiotherapy boost and conventional Brachytherapy in treating cervical cancer. Methods: Five HDR tandem and ovoid patients were planned using the Brachyvision treatment planning system and treated in four fractions using the Varian Varisource afterloader (Varian Medical Systems). For the same cohort, the patient planning CTs were imported into Multiplan (Accuray Inc) and a dose/fractionation-equivalent CyberKnife SBRT plan was retrospectively generated. Dosimetric quantities such as target/CTV D90, V90, D2cc for rectum, bladder, and bowel were measured and compared between the two modalities. Results: The CTV D90 for the tandem and ovoid was 2540cGy (90.7%) and 3009cGy (107.5%) for the CyberKnife plan. The D2cc for the rectum, bladder, and bowel were 1576cGy, 1641cGy, and 996cGy for the tandem and ovoid and 1374cGy, 1564cGy, and 1547cGy for CyberKnife. Conclusion: The D2cc doses to critical structures are comparable in both modalities. The CTV coverage is far superior for the CyberKnife plan. The dose distribution for CyberKnife has the advantage of increased conformality and lower maximum CTV dose.

  17. Peripheral doses in patients undergoing Cyberknife treatment for intracranial lesions. A single centre experience

    International Nuclear Information System (INIS)

    Vlachopoulou, Vassiliki; Antypas, Christos; Delis, Harry; Tzouras, Argyrios; Salvaras, Nikolaos; Kardamakis, Dimitrios; Panayiotakis, George

    2011-01-01

    Stereotactic radiosurgery/radiotherapy procedures are known to deliver a very high dose per fraction, and thus, the corresponding peripheral dose could be a limiting factor for the long term surviving patients. The aim of this clinical study was to measure the peripheral dose delivered to patients undergoing intracranial Cyberknife treatment, using the MOSFET dosimeters. The influence of the supplemental shielding, the number of monitor units and the collimator size to the peripheral dose were investigated. MOSFET dosimeters were placed in preselected anatomical regions of the patient undergoing Cyberknife treatment, namely the thyroid gland, the nipple, the umbilicus and the pubic symphysis. The mean peripheral doses before the supplemental shielding was added to the Cyberknife unit were 51.79 cGy, 13.31 cGy and 10.07 cGy while after the shielding upgrade they were 38.40 cGy, 10.94 cGy, and 8.69 cGy, in the thyroid gland, the umbilicus and the pubic symphysis, respectively. The increase of the collimator size corresponds to an increase of the PD and becomes less significant at larger distances, indicating that at these distances the PD is predominate due to the head leakage and collimator scatter. Weighting the effect of the number of monitor units and the collimator size can be effectively used during the optimization procedure in order to choose the most suitable treatment plan that will deliver the maximum dose to the tumor, while being compatible with the dose constraints for the surrounding organs at risk. Attention is required in defining the thyroid gland as a structure of avoidance in the treatment plan especially in patients with benign diseases

  18. Peripheral doses in patients undergoing Cyberknife treatment for intracranial lesions. A single centre experience

    Directory of Open Access Journals (Sweden)

    Vlachopoulou Vassiliki

    2011-11-01

    Full Text Available Abstract Background Stereotactic radiosurgery/radiotherapy procedures are known to deliver a very high dose per fraction, and thus, the corresponding peripheral dose could be a limiting factor for the long term surviving patients. The aim of this clinical study was to measure the peripheral dose delivered to patients undergoing intracranial Cyberknife treatment, using the MOSFET dosimeters. The influence of the supplemental shielding, the number of monitor units and the collimator size to the peripheral dose were investigated. Methods MOSFET dosimeters were placed in preselected anatomical regions of the patient undergoing Cyberknife treatment, namely the thyroid gland, the nipple, the umbilicus and the pubic symphysis. Results The mean peripheral doses before the supplemental shielding was added to the Cyberknife unit were 51.79 cGy, 13.31 cGy and 10.07 cGy while after the shielding upgrade they were 38.40 cGy, 10.94 cGy, and 8.69 cGy, in the thyroid gland, the umbilicus and the pubic symphysis, respectively. The increase of the collimator size corresponds to an increase of the PD and becomes less significant at larger distances, indicating that at these distances the PD is predominate due to the head leakage and collimator scatter. Conclusion Weighting the effect of the number of monitor units and the collimator size can be effectively used during the optimization procedure in order to choose the most suitable treatment plan that will deliver the maximum dose to the tumor, while being compatible with the dose constraints for the surrounding organs at risk. Attention is required in defining the thyroid gland as a structure of avoidance in the treatment plan especially in patients with benign diseases.

  19. CyberKnife with Tumor Tracking: An Effective Treatment for High-Risk Surgical Patients with Single Peripheral Lung Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Snider, James W.; Oermann, Eric K.; Chen, Viola; Rabin, Jennifer; Suy, Simeng; Yu, Xia [Department of Radiation Medicine, Georgetown University Hospital, Washington, DC (United States); Vahdat, Saloomeh [Department of Pathology, Georgetown University Hospital, Washington, DC (United States); Collins, Sean P. [Department of Radiation Medicine, Georgetown University Hospital, Washington, DC (United States); Banovac, Filip [Department of Radiology, Georgetown University Hospital, Washington, DC (United States); Anderson, Eric [Division of Pulmonary, Critical Care and Sleep Medicine, Georgetown University Hospital, Washington, DC (United States); Collins, Brian T., E-mail: collinsb@gunet.georgetown.edu [Department of Radiation Medicine, Georgetown University Hospital, Washington, DC (United States)

    2012-06-29

    Standard treatment for operable patients with single peripheral lung metastases is metastasectomy. We report mature CyberKnife outcomes for high-risk surgical patients with biopsy proven single peripheral lung metastases. Twenty-four patients (median age 73 years) with a mean maximum tumor diameter of 2.5 cm (range, 0.8–4.5 cm) were treated over a 6-year period extending from September 2004 to September 2010 and followed for a minimum of 1 year or until death. A mean dose of 52 Gy (range, 45–60 Gy) was delivered to the prescription isodose line in three fractions over a 3–11 day period (mean, 7 days). At a median follow-up of 20 months, the 2-year Kaplan–Meier local control and overall survival rates were 87 and 50%, respectively. CyberKnife with fiducial tracking is an effective treatment for high-risk surgical patients with single small peripheral lung metastases. Trials comparing CyberKnife with metastasectomy for operable patients are necessary to confirm equivalence.

  20. Fractionated stereotactic irradiation by Cyberknife of choroid melanomas: repositioning validation, closed eyelids

    International Nuclear Information System (INIS)

    Horn, S.; Rezvoy, N.; Lacornerie, T.; Mirabel, X.; Labalette, P.; Lartigau, E.

    2009-01-01

    The fractionated stereotactic radiotherapy by Cyberknife is an option in the treatment of eyes tumors. The advantages of the Cyberknife in the choroid melanomas are in its infra-millimetric precision, to the automated repositioning on the skull bones and to the conformity brought by the stereotaxy. The objective of this study was to validate the quality of repositioning and the immobility of the eyes with closed eyelids. Conclusion: the reproducibility of the eye positioning with closed eyelids seems enough to consider the conservative treatment of choroid melanomas by fractionated stereotactic radiotherapy by Cyberknife without implementation of fiducials nor retrobulbar anaesthesia. (N.C.)

  1. CyberKnife SRS: new technologies that enhance the treatment of cancer

    International Nuclear Information System (INIS)

    Cohen, A.

    2008-01-01

    The CyberKnife Robotic Radiosurgery System (Accuracy Incorporated, Sunnyvale, CA, USA) is used worldwide to treat tumors and neurological disorders anywhere in the body with sub-millimetre beam delivery accuracy. Accuracy has developed a number of new technologies in recent years to enhance the treatment of cancer patients. Such new technologies include a fast Monte Carlo Dose Calculation algorithm, Sequential Optimization dose planning, the Iris TM Variable Aperture Collimator, an 800 MU/min Linear Accelerator, and Optimized Path Traversal. These technologies enable physicists and physicians to plan treatments quickly and easily and deliver them with unrivalled accuracy and precision

  2. Cyberknife : how has it changed the radiotherapy practice?

    International Nuclear Information System (INIS)

    Hukku, S.

    2016-01-01

    The CyberKnife is a frameless robotic radiosurgery system used for treating benign tumors, malignant tumors and other medical conditions. The system was invented by John R. Adler, a Stanford University professor of neurosurgery and radiation oncology, and Peter and Russell Schonberg of Schonberg Research Corporation. It is the most accurate and flexible tool available for aggressive therapeutic irradiation. It is a method of delivering radiotherapy, with the intention of targeting treatment more accurately than standard radiotherapy. The two main elements of the CyberKnife are: 1. The radiation produced from a small linear particle accelerator (linac) 2. A robotic arm which allows the energy to be directed at any part of the body from any direction. Several generations of the CyberKnife system have been developed since its initial inception in 1990

  3. Extracranial Facial Nerve Schwannoma Treated by Hypo-fractionated CyberKnife Radiosurgery.

    Science.gov (United States)

    Sasaki, Ayaka; Miyazaki, Shinichiro; Hori, Tomokatsu

    2016-09-21

    Facial nerve schwannoma is a rare intracranial tumor. Treatment for this benign tumor has been controversial. Here, we report a case of extracranial facial nerve schwannoma treated successfully by hypo-fractionated CyberKnife (Accuray, Sunnyvale, CA) radiosurgery and discuss the efficacy of this treatment. A 34-year-old female noticed a swelling in her right mastoid process. The lesion enlarged over a seven-month period, and she experienced facial spasm on the right side. She was diagnosed with a facial schwannoma via a magnetic resonance imaging (MRI) scan of the head and neck and was told to wait until the facial nerve palsy subsides. She was referred to our hospital for radiation therapy. We planned a fractionated CyberKnife radiosurgery for three consecutive days. After CyberKnife radiosurgery, the mass in the right parotid gradually decreased in size, and the facial nerve palsy disappeared. At her eight-month follow-up, her facial spasm had completely disappeared. There has been no recurrence and the facial nerve function has been normal. We successfully demonstrated the efficacy of CyberKnife radiosurgery as an alternative treatment that also preserves neurofunction for facial nerve schwannomas.

  4. Peripheral dose measurement for CyberKnife radiosurgery with upgraded linac shielding

    International Nuclear Information System (INIS)

    Chuang, Cynthia F.; Larson, David A.; Zytkovicz, Andrea; Smith, Vernon; Petti, Paula L.

    2008-01-01

    The authors investigated the peripheral dose reduction for CyberKnife radiosurgery treatments after the installation of a linac shielding upgrade. As in a previous investigation, the authors considered two treatment plans, one for a hypothetical target in the brain and another for a target in the thorax, delivered to an anthropomorphic phantom. The results of the prior investigation showed that the CyberKnife delivered significantly higher peripheral doses than comparable model C Gamma Knife or IMRT treatments. Current measurements, after the linac shielding upgrade, demonstrate that the additional shielding decreased the peripheral dose, expressed as a percentage of the delivered monitor units (MU), by a maximum of 59%. The dose reduction was greatest for cranial-caudal distances from the field edge less than 30 cm, and at these distances, the CyberKnife peripheral dose, expressed as a percentage of the delivered MU, is now comparable to that measured for the other treatment modalities in our previous investigation. For distances between 30 and 70 cm from the field edge, the additional shielding reduced the peripheral dose by between 20% and 55%. At these distances, the CyberKnife peripheral dose remains higher than doses measured in our previous study for the model C Gamma Knife and IMRT

  5. SU-F-SPS-11: The Dosimetric Comparison of Truebeam 2.0 and Cyberknife M6 Treatment Plans for Brain SRS Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Mabhouti, H; Sanli, E; Cebe, M; Codel, G; Pacaci, P; Serin, E; Kucuk, N; Kucukmorkoc, E; Doyuran, M; Canoglu, D; Altinok, A; Acar, H; Caglar Ozkok, H [Medipol University, Istanbul, Istanbul (Turkey)

    2016-06-15

    Purpose: Brain stereotactic radiosurgery involves the use of precisely directed, single session radiation to create a desired radiobiologic response within the brain target with acceptable minimal effects on surrounding structures or tissues. In this study, the dosimetric comparison of Truebeam 2.0 and Cyberknife M6 treatment plans were made. Methods: For Truebeam 2.0 machine, treatment planning were done using 2 full arc VMAT technique with 6 FFF beam on the CT scan of Randophantom simulating the treatment of sterotactic treatments for one brain metastasis. The dose distribution were calculated using Eclipse treatment planning system with Acuros XB algorithm. The treatment planning of the same target were also done for Cyberknife M6 machine with Multiplan treatment planning system using Monte Carlo algorithm. Using the same film batch, the net OD to dose calibration curve was obtained using both machine by delivering 0- 800 cGy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. Dose distribution were measured using EBT3 film dosimeter. The measured and calculated doses were compared. Results: The dose distribution in the target and 2 cm beyond the target edge were calculated on TPSs and measured using EBT3 film. For cyberknife plans, the gamma analysis passing rates between measured and calculated dose distributions were 99.2% and 96.7% for target and peripheral region of target respectively. For Truebeam plans, the gamma analysis passing rates were 99.1% and 95.5% for target and peripheral region of target respectively. Conclusion: Although, target dose distribution calculated accurately by Acuros XB and Monte Carlo algorithms, Monte carlo calculation algorithm predicts dose distribution around the peripheral region of target more accurately than Acuros algorithm.

  6. Frame-less image-guided intracranial and extracranial radiosurgery using the Cyberknife robotic system

    International Nuclear Information System (INIS)

    Gibbs, I.C.

    2006-01-01

    The Cyberknife TM is an image-guided robotic radiosurgery system. The image guidance system includes a kilo-voltage X-ray imaging source and amorphous silica detectors. The radiation delivery device is a mobile X-band linear accelerator mounted onto a robotic arm. Through a highly complex interplay between the image guidance system, an automated couch, and the high-speed linear accelerator, near real-time tracking of the target is achieved. The Cyberknife TM gained Federal Drug Administration clearance in the United States in 2001 for treatment of tumors 'anywhere in the body where radiation treatment is indicated'. Because the Cyberknife TM system does not rely on rigid fixation of a stereotactic frame, tumors outside of the intracranial compartment, even those tumors that move with respiration can be treated with a similar degree of ease as intracranial targets. A description of the Cyberknife TM technology and a review of some of the current intracranial and extracranial applications are detailed herein. (author)

  7. Evaluation of clinically applied treatment beams with respect to bunker shielding parameters for a Cyberknife M6.

    Science.gov (United States)

    Henzen, Dominik; Schmidhalter, Daniel; Zanella, Claudia Christina; Volken, Werner; Mackeprang, Paul-Henry; Malthaner, Marco; Fix, Michael Karl; Manser, Peter

    2018-01-01

    Compared to a conventional linear accelerator, the Cyberknife (CK) is a unique system with respect to radiation protection shielding and the variety and number of non-coplanar beams are two key components regarding this aspect. In this work, a framework to assess the direction distribution and modulation factor (MF) of clinically applied treatment beams of a CyberKnife M6 is developed. Database filtering options allow studying the influence of different parameters such as collimator types, treatment sites or different bunker sizes. A distribution of monitor units (MU) is generated by projecting treatment beams onto the walls, floor and ceiling of the CyberKnife bunker. This distribution is found to be highly heterogeneous and depending, among other parameters, on the bunker size. For our bunker design, 10%-13% of the MUs are delivered to the right and left wall, each. The floor receives more than 64% of the applied MUs, while the wall behind the patient's head is not hit by primary treatment beams. Between 0% and 5% of the total MUs are delivered to the wall at the patient's feet. This number highly depends on the treatment site, e.g., for extracranial patients no beams hit that wall. Collimator choice was found to have minor influence on the distribution of MUs. On the other hand, the MF depends on the collimator type as well as on the treatment site. The MFs (delivered MU/prescribed dose) for all treatments, all MLC treatments, cranial and extracranial treatments are 8.3, 6.4, 7.7, and 9.9 MU/cGy, respectively. The developed framework allows assessing and monitoring important parameters regarding radiation protection of a CK-M6 using the actually applied treatment beams. Furthermore, it enables evaluating different clinical and constructional situations using the filtering options. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  8. The development of quality assurance program for cyberknife

    International Nuclear Information System (INIS)

    Jang, Ji Sun; Lee, Dong Han; Kang, Young Nam

    2006-01-01

    Standardization quality assurance (QA)program of Cyberknife for suitable circumstances in Korea has not been established. In this research, we investigated the development of QA program for Cyberknife and evaluation of the feasibility under applications. Considering the feature of constitution for systems and the therapeutic methodology of Cyberknife, the list of quality control (QC) was established and divided dependent on the each period of operations. And then all these developed QC lists were categorized into three groups such as basic QC, delivery specific QC, and patient specific QC based on the each purpose of QA. In order to verify the validity of the established QA program, this QC lists was applied to two Cyberknife centers. The acceptable tolerance was based on the undertaking inspection list from the Cyberknife manufacturer and the QC results during last three years of two Cyberknife centers in Korea. The acquired measurement results were evaluated for the analysis of the current QA status and the verification of the propriety for the developed QA program. The current QA status of two Cyberknife centers was evaluated from the accuracy of all measurements in relation with application of the established QA program. Each measurement result was verified having a good agreement within the acceptable tolerance limit of the developed QA program. It is considered that the developed QA program in this research could be established the standardization of QC methods for Cyberknife and confirmed the accuracy and stability for the image-guided stereotactic radiotherapy

  9. Direct tumor in vivo dosimetry in highly-conformal radiotherapy: A feasibility study of implantable MOSFETs for hypofractionated extracranial treatments using the Cyberknife system

    International Nuclear Information System (INIS)

    Scalchi, Paolo; Righetto, Roberto; Cavedon, Carlo; Francescon, Paolo; Colombo, Federico

    2010-01-01

    Purpose: In highly-conformal radiotherapy, due to the complexity of both beam configurations and dose distributions, traditional in vivo dosimetry is unpractical or even impossible. The ideal dosimeter would be implanted inside the planning treatment volume so that it can directly measure the total delivered dose during each fraction with no additional uncertainty due to calculation models. The aim of this work is to verify if implantable metal oxide semiconductors field effect transistors (MOSFETs) can achieve a sufficient degree of dosimetric accuracy when used inside extracranial targets undergoing radiotherapy treatments using the Cyberknife system. Methods: Based on the preliminary findings of this study, new prototypes for high dose fractionations were developed to reduce the time dependence for long treatment delivery times. These dosimeters were recently cleared and are marketed as DVS-HFT. Multiple measurements were performed using both Virtual Water and water phantoms to characterize implantable MOSFETs under the Cyberknife beams, and included the reference-dosimetry consistency, the dependence of the response on the collimator size, on the daily delivered dose, and the time irradiation modality. Finally a Cyberknife prostate treatment simulation using a body phantom was conducted, and both MOSFET and ionization readings were compared to Monte Carlo calculations. The feasibility analysis was conducted based on the ratios of the absorbed dose divided by the dose reading, named as ''further calibration factor'' (FCF). Results: The average FCFs resulted to be 0.98 for the collimator dependence test, and about 1.00 for the reference-dosimetry test, the dose-dependence test, and the time-dependence test. The average FCF of the prostate treatment simulation test was 0.99. Conclusions: The obtained results are well within DVS specifications, that is, the factory calibration is still valid for such kind of treatments using the Cyberknife system, with no need of

  10. Patient-reported quality of life progression in men with prostate cancer following primary cryotherapy, cyberknife, or active holistic surveillance.

    Science.gov (United States)

    Werneburg, Glenn T; Kongnyuy, Michael; Halpern, Daniel M; Salcedo, Jose M; Kosinski, Kaitlin E; Haas, Jonathan A; Schiff, Jeffrey T; Corcoran, Anthony T; Katz, Aaron E

    2017-12-07

    Technological advancements have led to the success of minimally invasive treatment modalities for prostate cancer such as CyberKnife and Cryotherapy. Here, we investigate patient-reported urinary function, bowel habits, and sexual function in patients following CyberKnife (CK) or Cryotherapy treatment, and compare them with active holistic surveillance (AHS) patients. An IRB-approved institutional database was retrospectively reviewed for patients who underwent CK, Cryotherapy, or AHS. Quality of life (QoL) survey responses were collected every three months and the mean function scores were analyzed in yearly intervals over the 4 years post-treatment. 279 patients (767 survey sets) were included in the study. There was no difference among groups in urinary function scores. The CyberKnife group had significantly lower bowel habit scores in the early years following treatment (year 2 mean difference: -5.4, P treatment. A history of hormonal therapy was associated with a lower sexual function scores relative to those patients who did not receive hormones in both CyberKnife (-18.45, P < 0.01) and Cryotherapy patients (-14.6, P < 0.05). After initial lower bowel habits and sexual function scores, CyberKnife or Cryotherapy-treated patients had no significant difference in QoL relative to AHS patients. These results highlight the benefit of CyberKnife and Cryotherapy in the management of organ-confined prostate cancer.

  11. Preliminary shielding calculation for the system of CyberKnife robotic radiosurgery; Calculo de blindagem preliminar para o sistema de radiocirurgia robotica CyberKnife

    Energy Technology Data Exchange (ETDEWEB)

    Toreti, Dalila; Xavier, Clarice; Moura, Fabio, E-mail: clarice.xavier@rem.ind.b, E-mail: fabio.moura@rem.ind.b [REM Industria e Comercio Ltda., Sao Paulo, SP (Brazil)

    2011-10-26

    The CyberKnife robotic system uses a manipulator with six grade of freedom for positioning a 6 MV Linac accelerator for treatment of lesions. This paper presents calculations for a standard room, with 200 cm of thickness walls primary, build for a CyberKnife system, and calculations for a room originally designed for a Linac conventional (with gantry), with secondary barriers of 107 cm thickness. After the realization of shielding for both rooms, the results shown that walls of standard room with 200 cm thickness are adequate for the secondary shield, and for a room with a conventional Linac, from all six evaluated points, two would require additional shielding of nine cm and four cm of concrete with 2.4 g/cubic cm. This shows that the CyberKnife system can be installed in a originally designed room for a conventional Linac with neither restrict nor any shielding, since no incidence of beams on the secondary barriers is existent

  12. TH-AB-201-01: A Feasibility Study of Independent Dose Verification for CyberKnife

    International Nuclear Information System (INIS)

    Sato, A; Noda, T; Keduka, Y; Kawajiri, T; Itano, M; Yamazaki, T; Tachibana, H

    2016-01-01

    Purpose: CyberKnife irradiation is composed of tiny-size, multiple and intensity-modulated beams compared to conventional linacs. Few of the publications for Independent dose calculation verification for CyberKnife have been reported. In this study, we evaluated the feasibility of independent dose verification for CyberKnife treatment as Secondary check. Methods: The followings were measured: test plans using some static and single beams, clinical plans in a phantom and using patient’s CT. 75 patient plans were collected from several treatment sites of brain, lung, liver and bone. In the test plans and the phantom plans, a pinpoint ion-chamber measurement was performed to assess dose deviation for a treatment planning system (TPS) and an independent verification program of Simple MU Analysis (SMU). In the clinical plans, dose deviation between the SMU and the TPS was performed. Results: In test plan, the dose deviations were 3.3±4.5%, and 4.1±4.4% for the TPS and the SMU, respectively. In the phantom measurements for the clinical plans, the dose deviations were −0.2±3.6% for the TPS and −2.3±4.8% for the SMU. In the clinical plans using the patient’s CT, the dose deviations were −3.0±2.1% (Mean±1SD). The systematic difference was partially derived from inverse square law and penumbra calculation. Conclusion: The independent dose calculation for CyberKnife shows −3.0±4.2% (Mean±2SD) and our study, the confidence limit was achieved within 5% of the tolerance level from AAPM task group 114 for non-IMRT treatment. Thus, it may be feasible to use independent dose calculation verification for CyberKnife treatment as the secondary check. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

  13. CyberKnife with Tumor Tracking: An Effective Treatment for High-Risk Surgical Patients with Stage I Non-Small Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Viola J.; Oermann, Eric [Department of Radiation Medicine, Georgetown University Hospital, Washington, DC (United States); Vahdat, Saloomeh [Department of Pathology, Georgetown University Hospital, Washington, DC (United States); Rabin, Jennifer; Suy, Simeng; Yu, Xia; Collins, Sean P. [Department of Radiation Medicine, Georgetown University Hospital, Washington, DC (United States); Subramaniam, Deepa [Division of Hematology and Oncology, Georgetown University Hospital, Washington, DC (United States); Banovac, Filip [Department of Radiology, Georgetown University Hospital, Washington, DC (United States); Anderson, Eric [Division of Pulmonary, Critical Care and Sleep Medicine, Georgetown University Hospital, Washington, DC (United States); Collins, Brian T., E-mail: collinsb@gunet.georgetown.edu [Department of Radiation Medicine, Georgetown University Hospital, Washington, DC (United States)

    2012-02-01

    Published data suggests that wedge resection for stage I non-small cell lung cancer (NSCLC) is associated with improved overall survival compared to stereotactic body radiation therapy. We report CyberKnife outcomes for high-risk surgical patients with biopsy-proven stage I NSCLC. PET/CT imaging was completed for staging. Three-to-five gold fiducial markers were implanted in or near tumors to serve as targeting references. Gross tumor volumes (GTVs) were contoured using lung windows; the margins were expanded by 5 mm to establish the planning treatment volume (PTV). Treatment plans were designed using a mean of 156 pencil beams. Doses delivered to the PTV ranged from 42 to 60 Gy in three fractions. The 30 Gy isodose contour extended at least 1 cm from the GTV to eradicate microscopic disease. Treatments were delivered using the CyberKnife system with tumor tracking. Examination and PET/CT imaging occurred at 3 month follow-up intervals. Forty patients (median age 76) with a median maximum tumor diameter of 2.6 cm (range, 1.4–5.0 cm) and a mean post-bronchodilator percent predicted forced expiratory volume in 1 s (FEV1) of 57% (range, 21–111%) were treated. A median dose of 48 Gy was delivered to the PTV over 3–13 days (median, 7 days). The 30 Gy isodose contour extended a mean 1.9 cm from the GTV. At a median 44 months (range, 12–72 months) follow-up, the 3 year Kaplan–Meier locoregional control and overall survival estimates compare favorably with contemporary wedge resection outcomes at 91 and 75%, respectively. CyberKnife is an effective treatment approach for stage I NSCLC that is similar to wedge resection, eradicating tumors with 1–2 cm margins in order to preserve lung function. Prospective randomized trials comparing CyberKnife with wedge resection are necessary to confirm equivalence.

  14. Spinal and para spinal tumors treated by Cyberknife: feasibility and efficacy

    International Nuclear Information System (INIS)

    Castelli, J.; Thariat, J.; Benezery, K.; Courdi, A.; Doyen, J.; Mammar, H.; Bondiau, P.Y.; Chanalet, S.; Paquis, P.; Frenay, M.

    2010-01-01

    Purpose Stereotactic radiotherapy using the Cyberknife has become a key treatment in the multidisciplinary management of secondary tumours, as well as primary benign or malignant tumours located within or adjacent to vertebral bodies and the spinal cord. The aim of this treatment is to improve local control and clinical response, including previously irradiated cases. Patients and methods In this study, we present the first patients treated with Cyberknife between December 2006 and December 2007 for spinal or para spinal tumours. The primary aim was to assess the feasibility and tolerance of stereotactic radiotherapy using the Cyberknife. Secondary aims were to establish the short-term local control, to calculate the local progression-free survival and overall survival. Clinical examination and imaging procedures were performed every three months. Response was assessed according to RECIST criteria. Results During that period, 16 patients were treated with Cyberknife. Thirteen patients had been pre-treated, three of whom had received spinal cord doses considered to be maximal. Three patients did not receive previous irradiation. The median age was 59 (36-74). The most frequent symptoms were pain (n = 8) and motor weakness (n = 4). The median dose was 30 Gy (16-50). The median number of fractions was 3 (1-5). No patient developed acute myelitis. Three patients developed acute reaction. Overall survival at 18 months was 72.4%, with a mean survival of 18.2 months (95% CI: 15.4-20.9). Local progression-free survival at 18 months was 58.4%, with a mean value of 16.9 months (95% CI: 13.6-20.2). Conclusion The use of stereotactic radiotherapy with Cyberknife represents a major progress in the management of para spinal tumours. The main advantages are better sparing of the spinal cord and the possibility of increasing the dose to the tumour target volume. (authors)

  15. Six-dimensional correction of intra-fractional prostate motion with CyberKnife stereotactic body radiation therapy

    Directory of Open Access Journals (Sweden)

    Sean eCollins

    2011-12-01

    Full Text Available AbstractLarge fraction radiation therapy offers a shorter course of treatment and radiobiological advantages for prostate cancer treatment. The CyberKnife is an attractive technology for delivering large fraction doses based on the ability to deliver highly conformal radiation therapy to moving targets. In addition to intra-fractional translational motion (left-right, superior-inferior and anterior-posterior, prostate rotation (pitch, roll and yaw can increase geographical miss risk. We describe our experience with six-dimensional (6D intrafraction prostate motion correction using CyberKnife stereotactic body radiation therapy (SBRT. Eighty-eight patients were treated by SBRT alone or with supplemental external radiation therapy. Trans-perineal placement of four gold fiducials within the prostate accommodated X-ray guided prostate localization and beam adjustment. Fiducial separation and non-overlapping positioning permitted the orthogonal imaging required for 6D tracking. Fiducial placement accuracy was assessed using the CyberKnife fiducial extraction algorithm. Acute toxicities were assessed using Common Toxicity Criteria (CTC v3. There were no Grade 3, or higher, complications and acute morbidity was minimal. Ninety-eight percent of patients completed treatment employing 6D prostate motion tracking with intrafractional beam correction. Suboptimal fiducial placement limited treatment to 3D tracking in 2 patients. Our experience may guide others in performing 6D correction of prostate motion with CyberKnife SBRT.

  16. Preliminary shielding calculation for the system of CyberKnife robotic radiosurgery

    International Nuclear Information System (INIS)

    Toreti, Dalila; Xavier, Clarice; Moura, Fabio

    2011-01-01

    The CyberKnife robotic system uses a manipulator with six grade of freedom for positioning a 6 MV Linac accelerator for treatment of lesions. This paper presents calculations for a standard room, with 200 cm of thickness walls primary, build for a CyberKnife system, and calculations for a room originally designed for a Linac conventional (with gantry), with secondary barriers of 107 cm thickness. After the realization of shielding for both rooms, the results shown that walls of standard room with 200 cm thickness are adequate for the secondary shield, and for a room with a conventional Linac, from all six evaluated points, two would require additional shielding of nine cm and four cm of concrete with 2.4 g/cubic cm. This shows that the CyberKnife system can be installed in a originally designed room for a conventional Linac with neither restrict nor any shielding, since no incidence of beams on the secondary barriers is existent

  17. Cyberknife fractionated radiotherapy for adrenal metastases: Preliminary report from a multispecialty Indian cancer care center

    Directory of Open Access Journals (Sweden)

    Trinanjan Basu

    2015-03-01

    Full Text Available Purpose: Metastasis to adrenal gland from lung, breast, and kidney malignancies are quite common. Historically radiotherapy was intended for pain palliation. Recent studies with stereotactic body radiotherapy (SBRT including Cyberknife robotic radiosurgery aiming at disease control brings about encouraging results. Here we represent the early clinical experience with Cyberknife stereotactic system from an Indian cancer care center. The main purpose of this retrospective review is to serve as a stepping stone for future prospective studies with non- invasive yet effective technique compared to surgery. Methods: We retrospectively reviewed four cases of adrenal metastases (three: lung and one: renal cell carcinoma treated with Cyberknife SBRT. X sight spine tracking was employed for planning and treatment delivery. Patients were evaluated for local response clinically as well as with PETCT based response criteria.Results: With a median gross tumor volume of 20.5 cc and median dose per fraction of 10 Gy, two patients had complete response (CR and two had partial response (PR when assessed 8-12 weeks post treatment as per RECIST. There was no RTOG grade 2 or more acute adverse events and organs at risk dosage were acceptable. Till last follow up all the patients were locally controlled and alive. Conclusion: Cyberknife SBRT with its unique advantages like non- invasive, short duration outpatient treatment technique culminating in similar local control rates in comparison to surgery is an attractive option. World literature of linear accelerator based SBRT and our data with Cyberknife SBRT with small sample size and early follow up are similar in terms of local control in adrenal metastases. Future prospective data would reveal more information on the management of adrenal metastases.

  18. Accelerated partial breast irradiation: Using the CyberKnife as the radiation delivery platform in the treatment of early breast cancer

    Directory of Open Access Journals (Sweden)

    Sandra eVermeulen

    2011-11-01

    Full Text Available We evaluate the CyberKnife (Accuray, Incorporated, Sunnyvale, CA for non-invasive delivery of accelerated partial breast irradiation (APBI in early breast cancer patients. Between 6/2009 and 5/2011, 9 patients were treated with CyberKnife APBI. Normal tissue constraints were imposed as outlined in the National Surgical Adjuvant Breast and Bowel Project B-39/Radiation Therapy Oncology Group 0413 (NSABP/RTOG Protocol (Vicini and White, 2007. Patients received a total dose of 30 Gy in 5 fractions (group 1, n=2 or 34 Gy in 10 fractions (group 2, n=7 delivered to the planning treatment volume (PTV defined as the clinical target volume (CTV + 2 mm. The CTV was defined as either the lumpectomy cavity plus 10 mm (n=2 or 15 mm (n=7. The cavity was defined by a T2-weighted non-contrast breast MRI fused to a planning non-contrast thoracic CT. The CyberKnife Synchrony system tracked gold fiducials sutured into the cavity wall during lumpectomy. Treatments started 4-5 weeks after lumpectomy. The mean PTV was 100 cm3 (range, 92-108 cm3 and 105 cm3 (range, 49-241 cm3 and the mean PTV isodose prescription line was 70% for groups 1 and 2, respectively. The mean percent of whole breast reference volume receiving 100% and 50% of the dose (V100 and V50 for group 1 was 11% (range, 8-13% and 23% (range, 16-30% and for group 2 was 11% (range, 7-14% and 26% (range, 21- 35.0% , respectively. At a median 7 months follow-up (range, 4-26 months, no acute toxicities were seen. Acute cosmetic outcomes were excellent or good in all patients; for those patients with more than 12 months follow-up the late cosmesis outcomes were excellent or good. In conclusion, the lack of observable acute side effects and current excellent/good cosmetic outcomes is promising. We believe this suggests the CyberKnife is a suitable non-invasive radiation platform for delivering APBI with achievable normal tissue constraints.

  19. Initial treatment results using cyberknife for head and neck tumor

    International Nuclear Information System (INIS)

    Himei, Kengo; Katsui, Kuniaki; Yoshida, Atsushi; Takemoto, Mitsuhiro; Kobayashi, Mitsuru; Kuroda, Masahiro; Hiraki, Yoshio

    2002-01-01

    The CyberKnife, a medical device for stereotactic radiotherapy, is composed of a combination of a robot manipulator and LINAC. For the treatment of head and neck tumors, this system has been applied. Between June 2000 and January 2001, 18 patients with head and neck tumor were treated with this system because of tumor recurrence, difficulty in surgery or additional increase after external radiotherapy. The median age was 64 years. Primary lesions were skull base (4), nasopharynx (3), paranasal sinus (3), nasal cavity (2), lacrimal gland (1), oropharynx (1), oral floor (1), and buccul mucosa (1), metastatic lymph nodes were found in three. The prescribed dose was 12-38 Gy as for marginal dose. The response rate (CR+PR) was 44.4% and local control rate (CR+PR+NC) was 77.8%. The adverse effects were assessed by the NCI-CTC Version 2.0 and observed grade 3 in two cases. Our early experience indicates that this system could to be feasible for the treatment of locally advanced or recurrent head and neck tumor, and for the reduction of adverse effect and maintenance of useful QOL of patients. (author)

  20. Extracranial stereotactic radiotherapy: preliminary results with the CyberKnife.

    Science.gov (United States)

    Lartigau, Eric; Mirabel, Xavier; Prevost, Bernard; Lacornerie, Thomas; Dubus, Francois; Sarrazin, Thierry

    2009-04-01

    In the field of radiation oncology, equipment for fractionated radiotherapy and single-dose radiosurgery has become increasingly accurate, together with the introduction of robotized treatments. A robot is a device that can be programmed to carry out accurate, repeated and adjusted tasks in a given environment. Treatment of extracranial lesions involves taking into account organ mobility (tumor and healthy tissue) whilst retaining the ability to stereotactically locate the target. New imaging techniques (single-photon emission computed tomography (SPECT), magnetic resonance imaging (MRI), positron emission tomography (PET)) provide further relevant information to slice images (computed tomography (CT) scans, MRI) for target definition. Hypo-fractionated treatments can only be used for curative treatment if the target is accurately defined and tracked during treatment. The CyberKnife is a non-invasive system of radiosurgery and fractionated stereotactic radiotherapy. For intracranial lesions treated by single-dose radiosurgery, it has been used to treat meningioma, acoustic neuromas, pituitary adenoma, metastases, arteriovenous malformations and refractory pain (trigeminal neuralgia). More than 10,000 patients have been treated worldwide. Currently, the most significant developments are in the field of extracranial stereotactic radiotherapy (lung, liver, reirradiation, prostate, etc.). Clinical results obtained in the CyberKnife Nord-Ouest program after 1 year of experience are presented. Copyright 2009 S. Karger AG, Basel.

  1. Lung tumor tracking during stereotactic radiotherapy treatment with the CyberKnife: Marker placement and early results

    International Nuclear Information System (INIS)

    Nuyttens, J.J.; Prevost, J.B.; Praag, J.; Hoogeman, M.; Levendag, P.C.; Klaveren, R.J. van; Pattynama, P.M.T.

    2006-01-01

    Lung tumor tracking during stereotactic radiotherapy with the CyberKnife requires the insertion of markers in or close to the tumor. To reduce the risk of pneumothorax, three methods of marker placement were used: 1) intravascular coil placement, 2) percutaneous intrathoracal, and 3) percutaneous extrathoracal placement. We investigated the toxicity of marker placement and the tumor response of the lung tumor tracking treatment. Markers were placed in 20 patients with 22 tumors: 13 patients received a curative treatment, seven a palliative. The median Charlson Comorbidity Score was 4 (range: 1-8). Platinum fiducials and intravascular embolisation coils were used as markers. In total, 78 markers were placed: 34 intrathoracal, 23 intravascular and 21 extrathoracal. The PTV equaled the GTV + 5 mm. A median dose of 45 Gy (range: 30-60 Gy, in 3 fractions) was prescribed to the 70-85% isodose. The response was evaluated with a CTscan performed 6-8 weeks after the last treatment and routinely thereafter. The median follow-up was 4 months (range: 2-11). No severe toxicity due to the marker placement was seen. Pneumothorax was not seen. The local control was 100%. Four tumors in four patients showed a complete response, 15 tumors in 14 patients a partial response, and three tumors in two patients with metastatic disease had stable disease. No severe toxicity of marker placement was seen due to the appropriate choice of one of the three methods. CyberKnife tumor tracking with markers is feasible and resulted in excellent tumor response. Longer follow-up is needed to validate the local control

  2. SU-F-T-620: Development of a Convolution/Superposition Dose Engine for CyberKnife System

    Energy Technology Data Exchange (ETDEWEB)

    Li, Y; Liu, B; Liang, B; Xu, X; Guo, B; Wei, R; Zhou, F [Beihang University, Beijing, Beijing (China); Song, T [Southern Medical University, Guangzhou, Guangdong (China); Xu, S [PLA General Hospital, Beijing, Beijing (China); Piao, J [302 Military Hospital, Beijing, Beijing (China)

    2016-06-15

    Purpose: Current CyberKnife treatment planning system (TPS) provided two dose calculation algorithms: Ray-tracing and Monte Carlo. Ray-tracing algorithm is fast, but less accurate, and also can’t handle irregular fields since a multi-leaf collimator system was recently introduced to CyberKnife M6 system. Monte Carlo method has well-known accuracy, but the current version still takes a long time to finish dose calculations. The purpose of this paper is to develop a GPU-based fast C/S dose engine for CyberKnife system to achieve both accuracy and efficiency. Methods: The TERMA distribution from a poly-energetic source was calculated based on beam’s eye view coordinate system, which is GPU friendly and has linear complexity. The dose distribution was then computed by inversely collecting the energy depositions from all TERMA points along 192 collapsed-cone directions. EGSnrc user code was used to pre-calculate energy deposition kernels (EDKs) for a series of mono-energy photons The energy spectrum was reconstructed based on measured tissue maximum ratio (TMR) curve, the TERMA averaged cumulative kernels was then calculated. Beam hardening parameters and intensity profiles were optimized based on measurement data from CyberKnife system. Results: The difference between measured and calculated TMR are less than 1% for all collimators except in the build-up regions. The calculated profiles also showed good agreements with the measured doses within 1% except in the penumbra regions. The developed C/S dose engine was also used to evaluate four clinical CyberKnife treatment plans, the results showed a better dose calculation accuracy than Ray-tracing algorithm compared with Monte Carlo method for heterogeneous cases. For the dose calculation time, it takes about several seconds for one beam depends on collimator size and dose calculation grids. Conclusion: A GPU-based C/S dose engine has been developed for CyberKnife system, which was proven to be efficient and accurate

  3. Poster - 49: Assessment of Synchrony respiratory compensation error for CyberKnife liver treatment

    International Nuclear Information System (INIS)

    Liu, Ming; Cygler, Joanna; Vandervoort, Eric

    2016-01-01

    The goal of this work is to quantify respiratory motion compensation errors for liver tumor patients treated by the CyberKnife system with Synchrony tracking, to identify patients with the smallest tracking errors and to eventually help coach patient’s breathing patterns to minimize dose delivery errors. The accuracy of CyberKnife Synchrony respiratory motion compensation was assessed for 37 patients treated for liver lesions by analyzing data from system logfiles. A predictive model is used to modulate the direction of individual beams during dose delivery based on the positions of internally implanted fiducials determined using an orthogonal x-ray imaging system and the current location of LED external markers. For each x-ray pair acquired, system logfiles report the prediction error, the difference between the measured and predicted fiducial positions, and the delivery error, which is an estimate of the statistical error in the model overcoming the latency between x-ray acquisition and robotic repositioning. The total error was calculated at the time of each x-ray pair, for the number of treatment fractions and the number of patients, giving the average respiratory motion compensation error in three dimensions. The 99 th percentile for the total radial error is 3.85 mm, with the highest contribution of 2.79 mm in superior/inferior (S/I) direction. The absolute mean compensation error is 1.78 mm radially with a 1.27 mm contribution in the S/I direction. Regions of high total error may provide insight into features predicting groups of patients with larger or smaller total errors.

  4. Poster - 49: Assessment of Synchrony respiratory compensation error for CyberKnife liver treatment

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ming [Carleton University (Canada); Cygler, Joanna [The Ottawa Hospital Cancer Centre, Carleton University, Ottawa University (Canada); Vandervoort, Eric [The Ottawa Hospital Cancer Centre, Ottawa University (Canada)

    2016-08-15

    The goal of this work is to quantify respiratory motion compensation errors for liver tumor patients treated by the CyberKnife system with Synchrony tracking, to identify patients with the smallest tracking errors and to eventually help coach patient’s breathing patterns to minimize dose delivery errors. The accuracy of CyberKnife Synchrony respiratory motion compensation was assessed for 37 patients treated for liver lesions by analyzing data from system logfiles. A predictive model is used to modulate the direction of individual beams during dose delivery based on the positions of internally implanted fiducials determined using an orthogonal x-ray imaging system and the current location of LED external markers. For each x-ray pair acquired, system logfiles report the prediction error, the difference between the measured and predicted fiducial positions, and the delivery error, which is an estimate of the statistical error in the model overcoming the latency between x-ray acquisition and robotic repositioning. The total error was calculated at the time of each x-ray pair, for the number of treatment fractions and the number of patients, giving the average respiratory motion compensation error in three dimensions. The 99{sup th} percentile for the total radial error is 3.85 mm, with the highest contribution of 2.79 mm in superior/inferior (S/I) direction. The absolute mean compensation error is 1.78 mm radially with a 1.27 mm contribution in the S/I direction. Regions of high total error may provide insight into features predicting groups of patients with larger or smaller total errors.

  5. Split-Volume Treatment Planning of Multiple Consecutive Vertebral Body Metastases for Cyberknife Image-Guided Robotic Radiosurgery

    International Nuclear Information System (INIS)

    Sahgal, Arjun; Chuang, Cynthia; Larson, David; Huang, Kim; Petti, Paula; Weinstein, Phil; Ma Lijun

    2008-01-01

    Cyberknife treatment planning of multiple consecutive vertebral body metastases is challenging due to large target volumes adjacent to critical normal tissues. A split-volume treatment planning technique was developed to improve the treatment plan quality of such lesions. Treatment plans were generated for 1 to 5 consecutive thoracic vertebral bodies (CVBM) prescribing a total dose of 24 Gy in 3 fractions. The planning target volume (PTV) consisted of the entire vertebral body(ies). Treatment plans were generated considering both the de novo clinical scenario (no prior radiation), imposing a dose limit of 8 Gy to 1 cc of spinal cord, and the retreatment scenario (prior radiation) with a dose limit of 3 Gy to 1 cc of spinal cord. The split-volume planning technique was compared with the standard full-volume technique only for targets ranging from 2 to 5 CVBM in length. The primary endpoint was to obtain best PTV coverage by the 24 Gy prescription isodose line. A total of 18 treatment plans were generated (10 standard and 8 split-volume). PTV coverage by the 24-Gy isodose line worsened consistently as the number of CVBM increased for both the de novo and retreatment scenario. Split-volume planning was achieved by introducing a 0.5-cm gap, splitting the standard full-volume PTV into 2 equal length PTVs. In every case, split-volume planning resulted in improved PTV coverage by the 24-Gy isodose line ranging from 4% to 12% for the de novo scenario and, 8% to 17% for the retreatment scenario. We did not observe a significant trend for increased monitor units required, or higher doses to spinal cord or esophagus, with split-volume planning. Split-volume treatment planning significantly improves Cyberknife treatment plan quality for CVBM, as compared to the standard technique. This technique may be of particular importance in clinical situations where stringent spinal cord dose limits are required

  6. Implementation of Fiducial-Based Image Registration in the Cyberknife Robotic System

    International Nuclear Information System (INIS)

    Saw, Cheng B.; Chen Hungcheng; Wagner, Henry

    2008-01-01

    Fiducial-based image registration methodology as implemented in the Cyberknife system is explored. The Cyberknife is a radiosurgery system that uses image guidance technology and computer-controlled robotics to determine target positions and adjust beam directions accordingly during the dose delivery. The image guidance system consists of 2 x-ray sources mounted on the ceiling and a detection system mounted on both sides of the treatment couch. Two orthogonal live radiographs are taken prior to and during patient treatment. Fiducial markers are identified on these radiographs and compared to a library of digital reconstructed radiographs (DRRs) using the fiducial extraction software. The fiducial extraction software initially sets an intensity threshold on the live radiographs to generate white areas on black images referred to as 'blobs.' Different threshold values are being used and blobs at the same location are assumed to originate from the same object. The number of blobs is then reduced by examining each blob against a predefined set of properties such as shape and exposure levels. The remaining blobs are further reduced by examining the location of the blobs in the inferior-superior patient axis. Those blobs that have the corresponding positions are assumed to originate from the same object. The remaining blobs are used to create fiducial configurations and are compared to the reference configuration from the computed tomography (CT) image dataset for treatment planning. The best-fit configuration is considered to have the appropriate fiducial markers. The patient position is determined based on these fiducial markers. During the treatment, the radiation beam is turned off when the Cyberknife changes nodes. This allows a time window to acquire live radiographs for the determination of the patient target position and to update the robotic manipulator to change beam orientations accordingly

  7. Cyberknife: A double edged sword?

    International Nuclear Information System (INIS)

    Joseph, B.; Ramachandra, A.; Supeb, S. S.

    2010-01-01

    The Cyberknife represents a new, frame less stereotactic radiosurgery system which efficiently incorporates advance robotics with computerized image reconstruction to allow highly conformal image guided radiation delivery. This review focus is on the pros and cons of this new radiotherapy tool, its current indications, safety profile and future directions. A literature search of Medline, Pubmed, Biomed, Medscape and Cancer lit database were referred to retrieve relevant data/information. The authors conclude that the use of this system offers an invaluable solution to the treatment of selective tumours/lesions located close to critical structures, salvage of recurrent and metastatic lesions and potential of treatment of selective early stage malignancies like the carcinoma prostate and lung. However, it is still too premature, with insufficient follow up data to advocate it as the treatment of choice in any set up. There are several radiobiological issues that also remain in the grey zone. (authors)

  8. Performance of a Motion Tracking System During Cyberknife Robotic Radiosurgery

    International Nuclear Information System (INIS)

    Cavedon, Carlo; Francescon, Paolo; Cora, Stefania; Moschini, Giuliano; Rossi, Paolo

    2009-01-01

    Cyberknife (Accuracy Inc., Ca) is a robotic radio-surgery system that includes a compact 6 MV linac delivering up to 800 cGy per minute, and an automate arm to aim at any part of the body from any angle. An essential tool is the guidance system based on x-ray imaging cameras located on supports around the patient. A Cyberknife system has been operational at the Vicenza (Italy) Hospital for years and is mainly employed for treating benign and malignant tumors, and Arterior-Venous Malformations. In radiation therapy, delivery of high doses to targets that move with respiration is challenging because of possible spatial inaccuracies. The purpose of this work was to estimate the accuracy of the prediction algorithm used to compensate for system latency in a real-time respiratory tracking system. We have analyzed respiratory signals of 30 patients who had lung or liver Cyberknife treatments. The 'Synchrony'(Accuracy Inc.) motion tracking system we use is based on the correlation between the position of LED markers, detected in real time, and the position of internal markers, sampled through x-ray imaging. The position of the external LED signals, though read in real time, must be predicted to compensate for a few hundred ms time lag in the feedback loop that redirects the beam to the current target position. The respiratory signals were described by employing their frequency power spectrum, as recently proposed by other authors. Prediction errors above 1.5 mm, lasting for periods longer than 5 seconds were observed for irregular breathers. These episodes correlate to the presence of a bimodal distribution in the power spectral density, and of very low frequencies contribution. A more refined approach would include a personalized choice of the prediction algorithm based on the very first minutes of treatment. Patient training aimed at reducing breathing irregularities might also result in improved spatial accuracy.

  9. A pencil beam dose calculation model for CyberKnife system

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Bin; Li, Yongbao; Liu, Bo; Zhou, Fugen [Image Processing Center, Beihang University, Beijing 100191 (China); Xu, Shouping [Department of Radiation Oncology, PLA General Hospital, Beijing 100853 (China); Wu, Qiuwen, E-mail: Qiuwen.Wu@Duke.edu [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710 (United States)

    2016-10-15

    Purpose: CyberKnife system is initially equipped with fixed circular cones for stereotactic radiosurgery. Two dose calculation algorithms, Ray-Tracing and Monte Carlo, are available in the supplied treatment planning system. A multileaf collimator system was recently introduced in the latest generation of system, capable of arbitrarily shaped treatment field. The purpose of this study is to develop a model based dose calculation algorithm to better handle the lateral scatter in an irregularly shaped small field for the CyberKnife system. Methods: A pencil beam dose calculation algorithm widely used in linac based treatment planning system was modified. The kernel parameters and intensity profile were systematically determined by fitting to the commissioning data. The model was tuned using only a subset of measured data (4 out of 12 cones) and applied to all fixed circular cones for evaluation. The root mean square (RMS) of the difference between the measured and calculated tissue-phantom-ratios (TPRs) and off-center-ratio (OCR) was compared. Three cone size correction techniques were developed to better fit the OCRs at the penumbra region, which are further evaluated by the output factors (OFs). The pencil beam model was further validated against measurement data on the variable dodecagon-shaped Iris collimators and a half-beam blocked field. Comparison with Ray-Tracing and Monte Carlo methods was also performed on a lung SBRT case. Results: The RMS between the measured and calculated TPRs is 0.7% averaged for all cones, with the descending region at 0.5%. The RMSs of OCR at infield and outfield regions are both at 0.5%. The distance to agreement (DTA) at the OCR penumbra region is 0.2 mm. All three cone size correction models achieve the same improvement in OCR agreement, with the effective source shift model (SSM) preferred, due to their ability to predict more accurately the OF variations with the source to axis distance (SAD). In noncircular field validation

  10. Extracranial Facial Nerve Schwannoma Treated by Hypo-fractionated CyberKnife Radiosurgery

    OpenAIRE

    Sasaki, Ayaka; Miyazaki, Shinichiro; Hori, Tomokatsu

    2016-01-01

    Facial nerve schwannoma is a rare intracranial tumor. Treatment for this benign tumor has been controversial. Here, we report a case of extracranial facial nerve schwannoma treated successfully by hypo-fractionated CyberKnife (Accuray, Sunnyvale, CA) radiosurgery?and discuss the efficacy of this treatment. A 34-year-old female noticed a swelling in her right mastoid process. The lesion enlarged over a seven-month period, and she experienced facial spasm on the right side. She was diagnosed wi...

  11. Establishing a process of irradiating small animal brain using a CyberKnife and a microCT scanner

    International Nuclear Information System (INIS)

    Kim, Haksoo; Welford, Scott; Fabien, Jeffrey; Zheng, Yiran; Yuan, Jake; Brindle, James; Yao, Min; Lo, Simon; Wessels, Barry; Machtay, Mitchell; Sohn, Jason W.; Sloan, Andrew

    2014-01-01

    Purpose: Establish and validate a process of accurately irradiating small animals using the CyberKnife G4 System (version 8.5) with treatment plans designed to irradiate a hemisphere of a mouse brain based on microCT scanner images. Methods: These experiments consisted of four parts: (1) building a mouse phantom for intensity modulated radiotherapy (IMRT) quality assurance (QA), (2) proving usability of a microCT for treatment planning, (3) fabricating a small animal positioning system for use with the CyberKnife's image guided radiotherapy (IGRT) system, and (4)in vivo verification of targeting accuracy. A set of solid water mouse phantoms was designed and fabricated, with radiochromic films (RCF) positioned in selected planes to measure delivered doses. After down-sampling for treatment planning compatibility, a CT image set of a phantom was imported into the CyberKnife treatment planning system—MultiPlan (ver. 3.5.2). A 0.5 cm diameter sphere was contoured within the phantom to represent a hemispherical section of a mouse brain. A nude mouse was scanned in an alpha cradle using a microCT scanner (cone-beam, 157 × 149 pixels slices, 0.2 mm longitudinal slice thickness). Based on the results of our positional accuracy study, a planning treatment volume (PTV) was created. A stereotactic body mold of the mouse was “printed” using a 3D printer laying UV curable acrylic plastic. Printer instructions were based on exported contours of the mouse's skin. Positional reproducibility in the mold was checked by measuring ten CT scans. To verify accurate dose delivery in vivo, six mice were irradiated in the mold with a 4 mm target contour and a 2 mm PTV margin to 3 Gy and sacrificed within 20 min to avoid DNA repair. The brain was sliced and stained for analysis. Results: For the IMRT QA using a set of phantoms, the planned dose (6 Gy to the calculation point) was compared to the delivered dose measured via film and analyzed using Gamma analysis (3% and 3 mm). A

  12. A cross sectional review of patient information available in the World Wide Web on CyberKnife: fallacies and pitfalls.

    Science.gov (United States)

    Menon, Durgapoorna; Chelakkot, Prameela G; Sunil, Devika; Lakshmaiah, Ashwini

    2017-12-01

    The purpose of this study is to assess the quality of videos available in YouTube on CyberKnife. The term "CyberKnife" was input into the search window of www.youtube.com on a specific date and the first 50 videos were assessed for technical and content issues. The data was tabulated and analysed. The search yielded 32,300 videos in 0.33 s. Among the first 50 analysed, most were professional videos, mostly on CyberKnife in general and for brain tumours. Most of the videos did not mention anything about patient selection or lesion size. The other technical details were covered by most although they seemed muffled by the animations. Many patient videos were recordings of one entire treatment, thus giving future patients an insight on what to expect. Almost half the videos projected glorified views about the treatment technique. The company videos were reasonably accurate and well presented as were many institutional videos, although there was a tendency to gloss over a few points. The glorification of the treatment technique was a disturbing finding. The profound trust of the patients on the health care system is humbling.

  13. Clinical observation on the therapeutic efficacy of CyberKnife for primary or metastatic retroperitoneal tumors

    International Nuclear Information System (INIS)

    Zhuang Hongqing; Yuan Zhiyong; Wang Ping

    2012-01-01

    Objective: To evaluate the early response rate and radiation toxicity of CyberKnife in the treatment of primary or metastatic retroperitoneal tumors. Methods: Twenty-eight patients with retroperitoneal tumors were treated with CyberKnife. The total doses were 2000-6000 cGy (median 4500 cGy) and biological effective doses were 3750-10080 cGy (median 7680 cGy) in 2-10 fractions (median 5). Of all patients, 3 received three dimensional conformal radiotherapy (3DCRT) or intensity modulated radiotherapy (IMRT) boost, 1 was treated as second-course radiotherapy, and others were treated with CyberKnife only. The survival rates were calculated by Kaplan-Meier method and compared with Logrank test. Results: The complete response, stable disease and progression disease rates were 43% (12/28), 6% (10/28), 18% (5/28), 4%, (1/28), respectively. The overall response rate was 96%. The number of patients who were followed up more than 1, 2, 3 years were 17, 9, 7, respectively. The 1-, 2- and 3-year local control rates were 92%, 86%, and 86%, respectively. The 1-, 2- and 3-year overall survival rates were 60%, 49% and 49%, respectively. The difference between local progression-free survival and overall survival was not significant (median 9.5 and 12.0 months, χ 2 =0.17, P=0.680), Moreover, if the patients did not have metastasis elsewhere and local treatment was effective, there was no significant difference between local progression-free survival and progression free survival (median 17 and 11 months, χ 2 =0.13, P=0.720), Acute radiation-induced side effects (≥ 2 grade) such as fatigue, anorexia, nausea, vomiting and epigastric discomfort occurred in 9, 9, 7, 7 and 2 patients, respectively. Intestinal stenosis of 1 grade occurred in 1 patients. Conclusions: Radiotherapy for retroperitoneal tumors with CyberKnife has provided a high response rate with minimal side effects. It is a safe and effective local treatment method for retroperitoneal tumors. (authors)

  14. Determination of acquisition frequency for intrafractional motion of pancreas in CyberKnife radiotherapy.

    Science.gov (United States)

    Zhang, Huailing; Zhao, Guoru; Djajaputra, David; Xie, Yaoqin

    2014-01-01

    To report the characteristics of pancreas motion as tracked using implanted fiducials during radiotherapy treatments with CyberKnife. Twenty-nine patients with pancreas cancer treated using CyberKnife system were retrospectively selected for this study. During the treatment, the deviation is examined every 3-4 nodes (~45 s interval) and compensated by the robot. The pancreas displacement calculated from X-ray images acquired within the time interval between two consecutive couch motions constitute a data set. A total of 498 data sets and 4302 time stamps of X-ray images were analyzed in this study. The average duration for each data set is 634 s. The location of the pancreas becomes more dispersed as the time elapses. The acquisition frequency depends on the prespecified movement distance threshold of pancreas. If the threshold between two consecutive images is 1 mm, the acquisition frequency should be less than 30 s, while if the threshold is 2 mm, the acquisition frequency can be around 1 min. The pancreas target moves significantly and unpredictably during treatment. Effective means of compensating the intrafractional movement is critical to ensure adequate dose coverage of the tumor target.

  15. TH-AB-201-05: Determining the Direction Distribution of the Primary Radiation for a Cyberknife-M6

    International Nuclear Information System (INIS)

    Henzen, D; Schmidhalter, D; Volken, W; Mackeprang, P-H; Malthaner, M; K Fix, M; Manser, P; C Zanella, C

    2016-01-01

    Purpose: Radiation protection regulatory differentiates between primary and scatter radiation. Whereas for conventional clinical linear accelerators the solid angle for primary radiation is planar, the Cyberknife (Accuray Inc., Sunnyvale, CA) may point its beam in all spatial directions. In order to be able to judge on radiation protection calculations for a Cyberknife-M6 vault, the direction distribution for delivered plans was evaluated based on clinical experiences. Methods: The log-files of 121 delivered patient treatment plans were exported, divided into cranial and extra-cranial treatments and the delivered monitor units (MU) together with the corresponding beam directions were analyzed. This MU-weighted spatial distribution was then projected to a 9.5 × 5.9 × 3.9 m 3 vault, generating an “intensity map” using a binning of 50 × 50 cm 2 . The factor of direction (FOD) is reported as a fraction of the total applied MUs to the walls, ceiling and floor in the perspective of a patient lying in head-first-supine position on the couch. In this study, the term intFOD refers to the integral FOD and maxFOD refers to the maximal FOD for a single bin. Results: For all kind of treatments and collimators, intFOD and maxFOD for the wall behind the patient’s head is 0.0. The intFOD for the floor varies between 0.65 and 0.74. For the ceiling, maxFOD is 0.002 and 0.0 for cranial and extra-cranial cases, respectively. The intFOD for the wall at the patient’s feet, is 0.094 for cranial and 0.005 for extra-cranial cases. There is nearly no difference between the maxFOD of the right and left wall for cranial cases, whereas for extra-cranial cases these numbers differ by a factor of 1.75. Conclusion: The varying FODs for the Cyberknife were quantified based on delivered treatment plans. These findings are helpful regarding the design of Cyberknife vaults.

  16. Real time tracking in liver SBRT: comparison of CyberKnife and Vero by planning structure-based γ-evaluation and dose-area-histograms.

    Science.gov (United States)

    Sothmann, T; Blanck, O; Poels, K; Werner, R; Gauer, T

    2016-02-21

    The purpose of this study was to evaluate and compare two clinical tracking systems for radiosurgery with regard to their dosimetric and geometrical accuracy in liver SBRT: the robot-based CyberKnife and the gimbal-based Vero. Both systems perform real-time tumour tracking by correlating internal tumour and external surrogate motion. CyberKnife treatment plans were delivered to a high resolution 2D detector array mounted on a 4D motion platform, with the platform simulating (a) tumour motion trajectories extracted from the corresponding CyberKnife predictor log files and (b) the tumour motion trajectories with superimposed baseline-drift. Static reference and tracked dose measurements were compared and dosimetric as well as geometrical uncertainties analyzed by a planning structure-based evaluation. For (a), γ-passing rates inside the CTV (γ-criteria of 1% / 1 mm) ranged from 95% to 100% (CyberKnife) and 98% to 100% (Vero). However, dosimetric accuracy decreases in the presence of the baseline-drift. γ-passing rates for (b) ranged from 26% to 92% and 94% to 99%, respectively; i.e. the effect was more pronounced for CyberKnife. In contrast, the Vero system led to maximum dose deviations in the OAR between  +1.5 Gy to +6.0 Gy (CyberKnife: +0.5 Gy to +3.5 Gy). Potential dose shifts were interpreted as motion-induced geometrical tracking errors. Maximum observed shift ranges were  -1.0 mm to  +0.7 mm (lateral) /-0.6 mm to +0.1 mm (superior-inferior) for CyberKnife and  -0.8 mm to +0.2 mm /-0.8 mm to +0.4 mm for Vero. These values illustrate that CyberKnife and Vero provide high precision tracking of regular breathing patterns. Even for the modified motion trajectory, the obtained dose distributions appear to be clinical acceptable with regard to literature QA γ-criteria of 3% / 3 mm.

  17. Determination of Acquisition Frequency for Intrafractional Motion of Pancreas in CyberKnife Radiotherapy

    Directory of Open Access Journals (Sweden)

    Huailing Zhang

    2014-01-01

    Full Text Available Purpose. To report the characteristics of pancreas motion as tracked using implanted fiducials during radiotherapy treatments with CyberKnife. Methods and Materials. Twenty-nine patients with pancreas cancer treated using CyberKnife system were retrospectively selected for this study. During the treatment, the deviation is examined every 3-4 nodes (~45 s interval and compensated by the robot. The pancreas displacement calculated from X-ray images acquired within the time interval between two consecutive couch motions constitute a data set. Results. A total of 498 data sets and 4302 time stamps of X-ray images were analyzed in this study. The average duration for each data set is 634 s. The location of the pancreas becomes more dispersed as the time elapses. The acquisition frequency depends on the prespecified movement distance threshold of pancreas. If the threshold between two consecutive images is 1 mm, the acquisition frequency should be less than 30 s, while if the threshold is 2 mm, the acquisition frequency can be around 1 min. Conclusions. The pancreas target moves significantly and unpredictably during treatment. Effective means of compensating the intrafractional movement is critical to ensure adequate dose coverage of the tumor target.

  18. Evaluation of target coverage and margins adequacy during CyberKnife Lung Optimized Treatment.

    Science.gov (United States)

    Ricotti, Rosalinda; Seregni, Matteo; Ciardo, Delia; Vigorito, Sabrina; Rondi, Elena; Piperno, Gaia; Ferrari, Annamaria; Zerella, Maria Alessia; Arculeo, Simona; Francia, Claudia Maria; Sibio, Daniela; Cattani, Federica; De Marinis, Filippo; Spaggiari, Lorenzo; Orecchia, Roberto; Riboldi, Marco; Baroni, Guido; Jereczek-Fossa, Barbara Alicja

    2018-04-01

    Evaluation of target coverage and verification of safety margins, in motion management strategies implemented by Lung Optimized Treatment (LOT) module in CyberKnife system. Three fiducial-less motion management strategies provided by LOT can be selected according to tumor visibility in the X ray images acquired during treatment. In 2-view modality the tumor is visible in both X ray images and full motion tracking is performed. In 1-view modality the tumor is visible in a single X ray image, therefore, motion tracking is combined with an internal target volume (ITV)-based margin expansion. In 0-view modality the lesion is not visible, consequently the treatment relies entirely on an ITV-based approach. Data from 30 patients treated in 2-view modality were selected providing information on the three-dimensional tumor motion in correspondence to each X ray image. Treatments in 1-view and 0-view modalities were simulated by processing log files and planning volumes. Planning target volume (PTV) margins were defined according to the tracking modality: end-exhale clinical target volume (CTV) + 3 mm in 2-view and ITV + 5 mm in 0-view. In the 1-view scenario, the ITV encompasses only tumor motion along the non-visible direction. Then, non-uniform ITV to PTV margins were applied: 3 mm and 5 mm in the visible and non-visible direction, respectively. We defined the coverage of each voxel of the CTV as the percentage of X ray images where such voxel was included in the PTV. In 2-view modality coverage was calculated as the intersection between the CTV centred on the imaged target position and the PTV centred on the predicted target position, as recorded in log files. In 1-view modality, coverage was calculated as the intersection between the CTV centred on the imaged target position and the PTV centred on the projected predictor data. In 0-view modality coverage was calculated as the intersection between the CTV centred on the imaged target position and the non

  19. Prostate-specific antigen kinetics after primary stereotactic body radiation therapy using CyberKnife for localized prostate cancer

    Directory of Open Access Journals (Sweden)

    Yong Hyun Park

    2015-03-01

    Conclusions: PSA decline occurred rapidly in the first month, and then the rate of PSA decline fell off steadily over time throughout 2 years after treatment. Also, SBRT using CyberKnife leads to long-term favorable BCR-free survival in localized prostate cancer.

  20. Establishing a process of irradiating small animal brain using a CyberKnife and a microCT scanner

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Haksoo; Welford, Scott [Department of Radiation Oncology, School of Medicine, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, Ohio 44106 (United States); Fabien, Jeffrey; Zheng, Yiran; Yuan, Jake; Brindle, James; Yao, Min; Lo, Simon; Wessels, Barry; Machtay, Mitchell; Sohn, Jason W., E-mail: jason.sohn@case.edu [Department of Radiation Oncology, School of Medicine, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, Ohio 44106 and University Hospitals of Cleveland, 11100 Euclid Avenue, Cleveland, Ohio 44106 (United States); Sloan, Andrew [Department of Neurosurgery, School of Medicine, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, Ohio 44106 (United States)

    2014-02-15

    Purpose: Establish and validate a process of accurately irradiating small animals using the CyberKnife G4 System (version 8.5) with treatment plans designed to irradiate a hemisphere of a mouse brain based on microCT scanner images. Methods: These experiments consisted of four parts: (1) building a mouse phantom for intensity modulated radiotherapy (IMRT) quality assurance (QA), (2) proving usability of a microCT for treatment planning, (3) fabricating a small animal positioning system for use with the CyberKnife's image guided radiotherapy (IGRT) system, and (4)in vivo verification of targeting accuracy. A set of solid water mouse phantoms was designed and fabricated, with radiochromic films (RCF) positioned in selected planes to measure delivered doses. After down-sampling for treatment planning compatibility, a CT image set of a phantom was imported into the CyberKnife treatment planning system—MultiPlan (ver. 3.5.2). A 0.5 cm diameter sphere was contoured within the phantom to represent a hemispherical section of a mouse brain. A nude mouse was scanned in an alpha cradle using a microCT scanner (cone-beam, 157 × 149 pixels slices, 0.2 mm longitudinal slice thickness). Based on the results of our positional accuracy study, a planning treatment volume (PTV) was created. A stereotactic body mold of the mouse was “printed” using a 3D printer laying UV curable acrylic plastic. Printer instructions were based on exported contours of the mouse's skin. Positional reproducibility in the mold was checked by measuring ten CT scans. To verify accurate dose delivery in vivo, six mice were irradiated in the mold with a 4 mm target contour and a 2 mm PTV margin to 3 Gy and sacrificed within 20 min to avoid DNA repair. The brain was sliced and stained for analysis. Results: For the IMRT QA using a set of phantoms, the planned dose (6 Gy to the calculation point) was compared to the delivered dose measured via film and analyzed using Gamma analysis (3% and 3 mm

  1. SU-F-T-611: Critical Analysis and Efficacy of Linac Based (Beam Modulator) and Cyberknife Treatment Plans for Acoustic Neuroma/schwannoma

    International Nuclear Information System (INIS)

    KP, Karrthick; Kataria, T; Thiyagarajan, R; Selvan, T; Abhishek, A

    2016-01-01

    Purpose: To study the critical analysis and efficacy of Linac and Cyberknife (CK) treatment plans for acoustic neuroma/schwannoma. Methods: Twelve of acoustic neuroma/schwannoma patients were taken for these study that. Treatment plans were generated in Multiplan treatment planning system (TPS) for CK using 5,7.5 and 10mm diameter collimators. Target volumes were in the range of 0.280 cc to 9.256 cc. Prescription dose (Rx) ranges from 1150cGy to 1950cGy delivered over 1 to 3 Fractions. For same patients stereotactic Volumetric modulated arc plans were generated using Elekta Linac with MLC thickness of 4mm in Monaco TPS. Appropriate calculation algorithms and grid size were used with same Rx and organ at risk (OAR) constrains for both Linac and CK plans. Treatment plans were developed to achieve at least 95% of the target volume to receive the Rx. The dosimetric indices such as conformity index (CI), coverage, OAR dose and volume receiving 50% of Rx (V50%) were used to evaluate the plans. Results: Target volumes ranges from 0.280 cc to 3.5cc shows the CI of 1.16±0.109 and 1.53±0.360 for cyberknife and Linac plans respectively. For small volume targets, the OARs were well spared in CK plans. There are no significant differences in CI and OAR doses were observed between CK and Linac plans that have the target volume >3.5 cc. Perhaps the V50% were lesser in CK plans, and found to be 12.8± 8.4 and 22.8 ± 15.0 for CK and Linac respectively. Conclusion: The analysis shows the importance of collimator size for small volume targets. The target volumes >3.5 cc can be treated in Linac as comparable with CK. For targets <3.5cc CK plans showed superior plan quality with better CI and OAR sparing than the Linac based plans. Further studies may require evaluating the clinical advantage of CK robotic system.

  2. Stereotactic Accelerated Partial Breast Irradiation (SAPBI for Early Stage Breast Cancer: Rationale, Feasibility and Early Experience using the CyberKnife Radiosurgery Delivery Platform

    Directory of Open Access Journals (Sweden)

    Olusola eOBAYOMI-DAVIES

    2016-05-01

    Full Text Available Purpose: The efficacy of accelerated partial breast irradiation (APBI utilizing brachytherapy or conventional external beam radiation has been studied in early stage breast cancer treated with breast conserving surgery. Data regarding stereotactic treatment approaches are emerging. The CyberKnife linear accelerator enables excellent dose conformality to target structures while adjusting for target and patient motion. We report our institutional experience on the technical feasibility and rationale for SAPBI delivery using the CyberKnife radiosurgery system.Methods: Ten patients completed CyberKnife SAPBI in 2013 at Georgetown University Hospital. Four gold fiducials were implanted around the lumpectomy cavity prior to treatment under ultrasound guidance. The synchrony system tracked intrafraction motion of the fiducials. The clinical target volume (CTV was defined on contrast enhanced CT scans using surgical clips and post-operative changes. A 5 mm expansion was added to create the planning treatment volume (PTV. A total dose of 30 Gy was delivered to the PTV in 5 consecutive fractions. Target and critical structure doses were assessed as per the National Surgical Adjuvant Breast and Bowel Project B-39 study.Results: At least 3 fiducials were tracked in 100% of cases. The Mean treated PTV was 70 cm3 and the mean prescription isodose line was 80%. Mean dose to target volumes and constraints are as follows: 100% of the PTV received the prescription dose (PTV30. The volume of the ipsilateral breast receiving 30 Gy (V30 and above 15 Gy (V>15 was 14% and 31% respectively. The ipsilateral lung volume receiving 9 Gy (V9 was 3% and the contralateral lung volume receiving 1.5 Gy (V1.5 was 8%. For left sided breast cancers, the volume of heart receiving 1.5 Gy (V1.5 was 31%. Maximum skin dose was 36 Gy. At a median follow up of 1.3 years, all patients have experienced excellent/good breast cosmesis outcomes, and no breast events have been recorded

  3. CyberKnife with tumor tracking: An effective alternative to wedge resection for high-risk surgical patients with stage I non-small cell lung cancer (NSCLC

    Directory of Open Access Journals (Sweden)

    Sean eCollins

    2012-02-01

    Full Text Available Published data suggests that wedge resection for stage I NSCLC results in improved overall survival compared to stereotactic body radiation therapy (SBRT. We report CyberKnife outcomes for high-risk surgical patients with biopsy-proven stage I NSCLC. PET/CT imaging was completed for staging. Three-to-five gold fiducial markers were implanted in or near tumors to serve as targeting references. Gross tumor volumes (GTVs were contoured using lung windows; the margins were expanded by 5 mm to establish the planning treatment volume (PTV. Treatment plans were designed using hundreds of pencil beams. Doses delivered to the PTV ranged from 42-60 Gy in 3 fractions. The 30-Gy isodose contour extended at least 1cm from the GTV to eradicate microscopic disease. Treatments were delivered using the CyberKnife system with tumor tracking. Examination and PET/CT imaging occurred at 3-month follow-up intervals. Forty patients (median age 76 with a median maximum tumor diameter of 2.6 cm (range, 1.4-5.0 cm and a mean post-bronchodilator percent predicted forced expiratory volume in 1 second (FEV1 of 57% (range, 21 - 111% were treated. A mean dose of 50 Gy was delivered to the PTV over 3 to 13 days (median, 7 days. The 30-Gy isodose contour extended a mean 1.9 cm from the GTV. At a median 44 months (range, 12 -72 months follow-up, the 3-year Kaplan-Meier locoregional control and overall survival estimates compare favorably with contemporary wedge resection outcomes at 91% and 75% , respectively. CyberKnife is an effective treatment approach for stage I NSCLC that is similar to wedge resection, eradicating tumors with 1 to 2 cm margins in order to preserve lung function. Prospective randomized trials comparing CyberKnife with wedge resection are necessary to confirm equivalence.

  4. Synchrony - Cyberknife Respiratory Compensation Technology

    International Nuclear Information System (INIS)

    Ozhasoglu, Cihat; Saw, Cheng B.; Chen Hungcheng; Burton, Steven; Komanduri, Krishna; Yue, Ning J.; Huq, Saiful M.; Heron, Dwight E.

    2008-01-01

    Studies of organs in the thorax and abdomen have shown that these organs can move as much as 40 mm due to respiratory motion. Without compensation for this motion during the course of external beam radiation therapy, the dose coverage to target may be compromised. On the other hand, if compensation of this motion is by expansion of the margin around the target, a significant volume of normal tissue may be unnecessarily irradiated. In hypofractionated regimens, the issue of respiratory compensation becomes an important factor and is critical in single-fraction extracranial radiosurgery applications. CyberKnife is an image-guided radiosurgery system that consists of a 6-MV LINAC mounted to a robotic arm coupled through a control loop to a digital diagnostic x-ray imaging system. The robotic arm can point the beam anywhere in space with 6 degrees of freedom, without being constrained to a conventional isocenter. The CyberKnife has been recently upgraded with a real-time respiratory tracking and compensation system called Synchrony. Using external markers in conjunction with diagnostic x-ray images, Synchrony helps guide the robotic arm to move the radiation beam in real time such that the beam always remains aligned with the target. With the aid of Synchrony, the tumor motion can be tracked in three-dimensional space, and the motion-induced dosimetric change to target can be minimized with a limited margin. The working principles, advantages, limitations, and our clinical experience with this new technology will be discussed

  5. Preliminary experience of extra-skull radiotherapy in stereotaxic conditions by Cyberknife at the Alexis-Vautrin Centre; Experience preliminaire de radiotherapie en conditions stereoxaques extracranienne par Cyberknife au centre Alexis-Vautrin

    Energy Technology Data Exchange (ETDEWEB)

    Peiffert, D.; Beckendorf, V.; Marchesi, V.; Noel, A. [Centre Alexis Vautrin, 54 - Vandoeuvre les Nancy (France); Noel, G. [Centre Paul Strauss, 67 -Strasbourg (France); Maingon, P. [Centre Georges Francois Leclerc, 21 - Dijon (France); Bosset, J.F. [Centre Hospitalier Universitaire, 25 - Besancon (France); Unterreiner, M. [Centre Francois Baclesse, 14 - Caen (France)

    2007-11-15

    The objective of this study is to evaluate the feasibility of the Cyberknife use for extra cerebral tumors by dint of' x.sight' osseous location for para-spinous lesions and 'tracking synchrony' for mobile targets. In conclusion, a training curve is necessary for the patients selection and the treatment implementation. The implantation and follow-up of the pellets need a trained team. A good cooperation of the patient is necessary; the carcinological follow-up will be analyzed ulteriorly. (N.C.)

  6. Image guidance quality assurance of a G4 CyberKnife robotic stereotactic radiosurgery system

    International Nuclear Information System (INIS)

    Pantelis, E; Antypas, C; Petrokokkinos, L

    2009-01-01

    The image guidance of a CyberKnife robotic radiosurgery system was quality controlled, including the overall performance of the target locating subsystem and the performance of the x-ray generators and flat panel digital cameras subcomponents. Accuracy and precision of the kV and exposure time settings of the x-ray generators, linearity of the x-ray output, spatial resolution and geometrical distortion of the acquired x-ray images were measured. Total accuracy and precision of the target locating subsystem in defining the position of an anthropomorphic head and neck phantom placed on treatment couch was also measured. Accuracy and precision of the kV as well as exposure time settings and linearity of the x-ray output were found within the acceptance limits suggested in diagnostic radiology. The acquired x-ray images were found to depict the shapes of the imaging objects without any geometrical distortion, being able to resolve differences in the features of imaging objects with critical frequency of 1.3 lp/mm and 1.5 lp/mm for camera A and B, respectively. Total target locating system accuracy was found within 0.2 mm and 0.2 deg. in translations and rotations, respectively. Corresponding precision was found lower than 0.5%. These findings render the target locating subsystem of the CyberKnife capable of accurately registering the patient to treatment position and monitoring patient's movement during treatment delivery.

  7. SU-E-T-642: Safety Procedures for Error Elimination in Cyberknife Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT)

    International Nuclear Information System (INIS)

    Hussain, A; Alkafi, A; Al-Najjar, W; Moftah, B

    2014-01-01

    Purpose: Cyberknife system is used for providing stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) hypofractionation scheme. The whole treatment delivery is based on live imaging of the patient. The minor error made at any stage may bring severe radiation injury to the patient or damage to the system itself. Several safety measures were taken to make the system safer. Methods: The radiation treatment provided thru a 6MV linac attached to Kuka robot (Cyberknife G4, Accuray Inc. Sunnyvale, CA, USA). Several possible errors were identified related to patient alignment, treatment planning, dose delivery and physics quality assurance. During dose delivery, manual and visual checks were introduced to confirm pre and intra-treatment imaging to reduce possible errors. One additional step was introduced to confirm that software tracking-tools had worked correctly with highest possible confidence level. Robotic head move in different orientations over and around the patient body, the rigidity of linac-head cover and other accessories was checked periodically. The vender was alerted when a tiny or bigger piece of equipment needed additional interlocked support. Results: As of our experience treating 525 patients on Cyberknife during the last four years, we saw on and off technical issues. During image acquisition, it was made essential to follow the site-specific imaging protocols. Adequate anatomy was contoured to document the respective doses. Followed by auto-segmentation, manual tweaking was performed on every structure. The calculation box was enclosing the whole image during the final calculation. Every plan was evaluated on slice-by slice basis. To review the whole process, a check list was maintained during the physics 2nd-check. Conclusion: The implementation of manual and visual additional checks introduced along with automated checks for confirmation was found promising in terms of reduction in systematic errors and making the system

  8. CyberKnife Boost for Patients with Cervical Cancer Unable to Undergo Brachytherapy

    International Nuclear Information System (INIS)

    Haas, Jonathan Andrew; Witten, Matthew R.; Clancey, Owen; Episcopia, Karen; Accordino, Diane; Chalas, Eva

    2012-01-01

    Standard radiation therapy for patients undergoing primary chemosensitized radiation for carcinomas of the cervix usually consists of external beam radiation followed by an intracavitary brachytherapy boost. On occasion, the brachytherapy boost cannot be performed due to unfavorable anatomy or because of coexisting medical conditions. We examined the safety and efficacy of using CyberKnife stereotactic body radiotherapy (SBRT) as a boost to the cervix after external beam radiation in those patients unable to have brachytherapy to give a more effective dose to the cervix than with conventional external beam radiation alone. Six consecutive patients with anatomic or medical conditions precluding a tandem and ovoid boost were treated with combined external beam radiation and CyberKnife boost to the cervix. Five patients received 45 Gy to the pelvis with serial intensity-modulated radiation therapy boost to the uterus and cervix to a dose of 61.2 Gy. These five patients received an SBRT boost to the cervix to a dose of 20 Gy in five fractions of 4 Gy each. One patient was treated to the pelvis to a dose of 45 Gy with an external beam boost to the uterus and cervix to a dose of 50.4 Gy. This patient received an SBRT boost to the cervix to a dose of 19.5 Gy in three fractions of 6.5 Gy. Five percent volumes of the bladder and rectum were kept to ≤75 Gy in all patients (i.e., V75 Gy ≤ 5%). All of the patients remain locally controlled with no evidence of disease following treatment. Grade 1 diarrhea occurred in 4/6 patients during the conventional external beam radiation. There has been no grade 3 or 4 rectal or bladder toxicity. There were no toxicities observed following SBRT boost. At a median follow-up of 14 months, CyberKnife radiosurgical boost is well tolerated and efficacious in providing a boost to patients with cervix cancer who are unable to undergo brachytherapy boost. Further follow-up is required to see if these results remain durable.

  9. CyberKnife robotic stereotactic radiotherapy: technical aspects and medical indications; Radiotherapie stereotaxique robotisee par CyberKnife: aspects techniques et indications

    Energy Technology Data Exchange (ETDEWEB)

    Bondiau, P.Y.; Benezery, K.; Gerard, J.P.; Herault, J.; Marcie, S.; Angellier, G. [Centre Antoine-Lacassagne, Dept. de Radiotherapie, 06 - Nice (France); Beckendorf, V.; Peiffert, D.; Noel, A. [Centre Alexis-Vautrin, Dept. de Radiotherapie et Curietherapie, 54 - Vandoeuvre-les-Nancy (France); Mirabel, X.; Marchesi, V.; Lacornerie, T.; Dubus, F.; Sarrazin, T.; Lartigau, E. [Centre Oscar-Lambret, Dept. de Radiotherapie, 59 - Lille (France)

    2007-11-15

    In 2006, 3 sites have been selected by the Institut national of cancer (Lille, Nancy et Nice) to evaluate a radiotherapy robot, the CyberKnife this machine, able to track mobile tumours in real time, gives new possibilities in the field of extra cranial stereotactic radiotherapy. Functionalities and medico economical issues of the machine will be evaluated during 2 years on the 3 sites. (authors)

  10. Analysis of the model of pulmonary lesions of the cyberknife system tracking

    International Nuclear Information System (INIS)

    Floriano Pardal, A.; Santa-Olalla, I.; Sanchez-Reyes, A.

    2013-01-01

    The CyberKnife VSI system has the ability to carry out treatments for injuries that move with respiration through tracking Synchrony system, compensating for the breathing of the patient through the robotic arm, and thus allowing the reduction of the volume of treatment PTV margins. Tumor tracking is based on a model of correspondence between the positions of internal fiduciales brands previously introduced in the patient, and the external positions of infrared transmitters placed on the patient. This model is associated with a few errors that should be taken into account. The objective of the study is twofold: on the one hand to study the movement of the PTV based on location, and on the other analyze errors associated with this respiratory model. (Author)

  11. SU-F-T-293: Experimental Comparisons of Ionization Chambers with Different Volumes for CyberKnife Delivery Quality Assurance

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, M [Kobe Minimally invasive Cancer Center, Kobe, Hyogo (Japan); Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Munetomo, Y; Ogata, T; Uehara, K; Tsudou, S; Nishimura, H; Mayahara, H [Kobe Minimally invasive Cancer Center, Kobe, Hyogo (Japan); Sasaki, R [Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan)

    2016-06-15

    Purpose: To evaluate the practicality use of ionization chambers with different volumes for delivery quality assurance of CyberKnife plans, Methods: Dosimetric measurements with a spherical solid water phantom and three ionization chambers with volumes of 0.13, 0.04, and 0.01 cm3 (IBA CC13, CC04, and CC01, respectively) were performed for various CyberKnife clinical treatment plans including both isocentric and nonisocentric delivery. For each chamber, the ion recombination correction factors Ks were calculated using the Jaffe plot method and twovoltage method at a 10-cm depth for a 60-mm collimator field in a water phantom. The polarity correction factors Kpol were determined for 5–60-mm collimator fields in same experimental setup. The measured doses were compared to the doses for the detectors calculated using a treatment planning system. Results: The differences in the Ks between the Jaffe plot method and two-voltage method were −0.12, −0.02, and 0.89% for CC13, CC04, and CC01, respectively. The changes in Kpol for the different field sizes were 0.2, 0.3, and 0.8% for CC13, CC04, and CC01, respectively. The measured doses for CC04 and CC01 were within 3% of the calculated doses for the clinical treatment plans with isocentric delivery with collimator fields greater than 12.5 mm. Those for CC13 had differences of over 3% for the plans with isocentric delivery with collimator fields less than 15 mm. The differences for the isocentric plans were similar to those for the single beam plans. The measured doses for each chamber were within 3% of the calculated doses for the non-isocentric plans except for that with a PTV volume less than 1.0 cm{sup 3}. Conclusion: Although there are some limitations, the ionization chamber with a smaller volume is a better detector for verification of the CyberKnife plans owing to the high spatial resolution.

  12. SU-F-T-601: Equivalence of CyberKnife and TrueBeam STx for Spine Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Herrington, J [University of Rhode Island, Kingston, RI (United States); Price, M; Brindle, J [University of Rhode Island, Kingston, RI (United States); Rhode Island Hospital, Providence, RI (United States); Alpert Medical School of Brown University (United States); Schmidt, M; Knutson, N [University of Rhode Island, Kingston, RI (United States); Rhode Island Hospital, Providence, RI (United States)

    2016-06-15

    Purpose: To evaluate the equivalence of spine SBRT treatment plans created in Eclipse for the TrueBeam STx (Varian Medical System, Palo Alto, CA) compared to plans using CyberKnife and MultiPlan (Accuray, Sunnyvale, CA). Methods: CT data and contours for 23 spine SBRT patients previously treated using CyberKnife (CK) were exported from MultiPlan treatment planning system into Eclipse where they were planned using static IMRT 6MV coplanar beams. Plans were created according to the original prescription dose and fractionation schedule while limiting spinal dose according to the RTOG 0631 protocol and maintaining target coverage comparable to the original CK plans. Plans were evaluated using new conformity index (nCI), homogeneity index (HI), dose-volume histogram data, number of MU, and estimated treatment time. To ensure all Eclipse plans were deliverable, standard clinical IMRT QA was performed. The plan results were matched with their complimentary CK plans for paired statistical analysis. Results: Plans generated in Eclipse demonstrated statistically significant (p<0.01) improvements compared to complimentary CK plans in median values of maximum spinal cord dose (17.39 vs. 18.12 Gy), RTOG spinal cord constraint dose (14.50 vs. 16.93 Gy), nCI (1.28 vs. 1.54), HI (1.13 vs. 1.27), MU (3918 vs. 36416), and estimated treatment time (8 vs. 48 min). All Eclipse generated plans passed our clinically used protocols for IMRT QA. Conclusion: CK spine SBRT replanned utilizing Eclipse for LINAC delivery demonstrated dosimetric advantages. We propose improvements in plan quality metrics reviewed in this study may be attributed to dynamic MLCs that facilitate treatment of complicated geometries as well as posterior beams ideal for centrally located and/or posterior targets afforded by gantry-based RT delivery.

  13. St. Joseph's Hospital Barrow Neurological Institute stereitatic radiotherapy experience comparison of Gamma Knife and CyberKnife

    International Nuclear Information System (INIS)

    Kresl, J.J.

    2006-01-01

    The clinical utilisation stereotactic radiotherapy continues to increase in breadth and scope within the medical community. However, no single standard treatment platform exists for the delivery of stereotactic radiotherapy treatments. This is because although there are several commercially available platforms capable of delivering stereotactic radiotherapy treatments, each platform has unique abilities and limitations. The most widely used stereotactic radiotherapy system for intracranial treatments is the Gamma Knife. The first image guided robotic stereotactic radiotherapy system enabling body stereotactic radiotherapy is the CyberKnife. Both are available at the Barrow Neurological Institute. We describe our experience with the complementary use of these two distinct treatment platforms. This permits us to make a meaningful comparison and to detail their contrasting advantages and disadvantages for state of the art for stereotactic radiotherapy. (author)

  14. Evaluation of Real-time Measurement Liver Tumor's Movement and SynchronyTM System's Accuracy of Radiosurgery using a Robot CyberKnife

    International Nuclear Information System (INIS)

    Kim, Gha Jung; Shim, Su Jung; Kim, Jeong Ho; Min, Chul Kee; Chung, Weon Kuu

    2008-01-01

    This study aimed to quantitatively measure the movement of tumors in real-time and evaluate the treatment accuracy, during the treatment of a liver tumor patient, who underwent radiosurgery with a Synchrony Respiratory motion tracking system of a robot CyberKnife. Materials and Methods: The study subjects included 24 liver tumor patients who underwent CyberKnife treatment, which included 64 times of treatment with the Synchrony Respiratory motion tracking system (SynchronyTM). The treatment involved inserting 4 to 6 acupuncture needles into the vicinity of the liver tumor in all the patients using ultrasonography as a guide. A treatment plan was set up using the CT images for treatment planning uses. The position of the acupuncture needle was identified for every treatment time by Digitally Reconstructed Radiography (DRR) prepared at the time of treatment planning and X-ray images photographed in real-time. Subsequent results were stored through a Motion Tracking System (MTS) using the Mtsmain.log treatment file. In this way, movement of the tumor was measured. Besides, the accuracy of radiosurgery using CyberKnife was evaluated by the correlation errors between the real-time positions of the acupuncture needles and the predicted coordinates. Results: The maximum and the average translational movement of the liver tumor were measured 23.5 mm and 13.9±5.5 mm, respectively from the superior to the inferior direction, 3.9 mm and 1.9±0.9 mm, respectively from left to right, and 8.3 mm and 4.9±1.9 mm, respectively from the anterior to the posterior direction. The maximum and the average rotational movement of the liver tumor were measured to be 3.3o and 2.6±1.3o, respectively for X (Left-Right) axis rotation, 4.8o and 2.3±1.0o, respectively for Y (Cranio-Caudal) axis rotation, 3.9o and 2.8±1.1o, respectively for Z (Anterior-Posterior) axis rotation. In addition, the average correlation error, which represents the treatment's accuracy was 1.1±0.7 mm. Conclusion

  15. SU-E-J-06: Additional Imaging Guidance Dose to Patient Organs Resulting From X-Ray Tubes Used in CyberKnife Image Guidance System

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, A; Ding, G [Vanderbilt University, Nashville, TN (United States)

    2015-06-15

    Purpose: The use of image-guided radiation therapy (IGRT) has become increasingly common, but the additional radiation exposure resulting from repeated image guidance procedures raises concerns. Although there are many studies reporting imaging dose from different image guidance devices, imaging dose for the CyberKnife Robotic Radiosurgery System is not available. This study provides estimated organ doses resulting from image guidance procedures on the CyberKnife system. Methods: Commercially available Monte Carlo software, PCXMC, was used to calculate average organ doses resulting from x-ray tubes used in the CyberKnife system. There are seven imaging protocols with kVp ranging from 60 – 120 kV and 15 mAs for treatment sites in the Cranium, Head and Neck, Thorax, and Abdomen. The output of each image protocol was measured at treatment isocenter. For each site and protocol, Adult body sizes ranging from anorexic to extremely obese were simulated since organ dose depends on patient size. Doses for all organs within the imaging field-of-view of each site were calculated for a single image acquisition from both of the orthogonal x-ray tubes. Results: Average organ doses were <1.0 mGy for every treatment site and imaging protocol. For a given organ, dose increases as kV increases or body size decreases. Higher doses are typically reported for skeletal components, such as the skull, ribs, or clavicles, than for softtissue organs. Typical organ doses due to a single exposure are estimated as 0.23 mGy to the brain, 0.29 mGy to the heart, 0.08 mGy to the kidneys, etc., depending on the imaging protocol and site. Conclusion: The organ doses vary with treatment site, imaging protocol and patient size. Although the organ dose from a single image acquisition resulting from two orthogonal beams is generally insignificant, the sum of repeated image acquisitions (>100) could reach 10–20 cGy for a typical treatment fraction.

  16. Evaluation of Real-time Measurement Liver Tumor's Movement and SynchronyTM System's Accuracy of Radiosurgery using a Robot CyberKnife

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gha Jung; Shim, Su Jung; Kim, Jeong Ho; Min, Chul Kee; Chung, Weon Kuu [Konyang University College of Medicine, Daejeon (Korea, Republic of)

    2008-12-15

    This study aimed to quantitatively measure the movement of tumors in real-time and evaluate the treatment accuracy, during the treatment of a liver tumor patient, who underwent radiosurgery with a Synchrony Respiratory motion tracking system of a robot CyberKnife. Materials and Methods: The study subjects included 24 liver tumor patients who underwent CyberKnife treatment, which included 64 times of treatment with the Synchrony Respiratory motion tracking system (SynchronyTM). The treatment involved inserting 4 to 6 acupuncture needles into the vicinity of the liver tumor in all the patients using ultrasonography as a guide. A treatment plan was set up using the CT images for treatment planning uses. The position of the acupuncture needle was identified for every treatment time by Digitally Reconstructed Radiography (DRR) prepared at the time of treatment planning and X-ray images photographed in real-time. Subsequent results were stored through a Motion Tracking System (MTS) using the Mtsmain.log treatment file. In this way, movement of the tumor was measured. Besides, the accuracy of radiosurgery using CyberKnife was evaluated by the correlation errors between the real-time positions of the acupuncture needles and the predicted coordinates. Results: The maximum and the average translational movement of the liver tumor were measured 23.5 mm and 13.9{+-}5.5 mm, respectively from the superior to the inferior direction, 3.9 mm and 1.9{+-}0.9 mm, respectively from left to right, and 8.3 mm and 4.9{+-}1.9 mm, respectively from the anterior to the posterior direction. The maximum and the average rotational movement of the liver tumor were measured to be 3.3o and 2.6{+-}1.3o, respectively for X (Left-Right) axis rotation, 4.8o and 2.3{+-}1.0o, respectively for Y (Cranio-Caudal) axis rotation, 3.9o and 2.8{+-}1.1o, respectively for Z (Anterior-Posterior) axis rotation. In addition, the average correlation error, which represents the treatment's accuracy was 1

  17. Poster — Thur Eve — 23: Dose and Position Quality Assurance using the RADPOS System for 4D Radiotherapy with CyberKnife

    Energy Technology Data Exchange (ETDEWEB)

    Marants, R [Department of Medical Physics, Carleton University (Canada); Vandervoort, E [Department of Medical Physics, The Ottawa Hospital Cancer Centre (Canada); Cygler, J E [Department of Medical Physics, Carleton University, Department of Medical Physics, The Ottawa Hospital Cancer Centre (Canada)

    2014-08-15

    Introduction: RADPOS 4D dosimetry system consists of a microMOSFET dosimeter combined with an electromagnetic positioning sensor, which allows for performing real-time dose and position measurements simultaneously. In this report the use of RADPOS as an independent quality assurance (QA) tool during CyberKnife 4D radiotherapy treatment is described. In addition to RADPOS, GAFCHROMIC® films were used for simultaneous dose measurement. Methods: RADPOS and films were calibrated in a Solid Water® phantom at 1.5 cm depth, SAD= 80 cm, using 60 mm cone. CT based treatment plan was created for a Solid Water® breast phantom containing metal fiducials and RADPOS probe. Dose calculations were performed using iPlan pencil beam algorithm. Before the treatment delivery, GAFCHROMIC® film was inserted inside the breast phantom, next to the RADPOS probe. Then the phantom was positioned on the chest platform of the QUASAR, to which Synchrony LED optical markers were also attached. Position logging began for RADPOS and the Synchrony tracking system, the QUASAR motion was initiated and the treatment was delivered. Results: RADPOS position measurements very closely matched the LED marker positions recorded by the Synchrony camera tracking system. The RADPOS measured dose was 2.5% higher than the average film measured dose, which is within the experimental uncertainties. Treatment plan calculated dose was 4.1 and 1.6% lower than measured by RADPOS and film, respectively. This is most likely due to the inferior nature of the dose calculation algorithm. Conclusions: Our study demonstrates that RADPOS system is a useful tool for independent QA of CyberKnife treatments.

  18. SU-E-T-767: Treatment Planning Study of Prostate Cancer by CyberKnife with Respect to the Urethral Dose

    International Nuclear Information System (INIS)

    Mizuno, H; Mizuno, H; Sumida, I; Otani, Y; Yagi, M; Takashina, M; Suzuki, O; Yoshioka, Y; Koizumi, M; Ogawa, K

    2015-01-01

    Purpose: Hypo-fractionated stereotactic body radiation therapy (SBRT) with intensity modulated radiation therapy (IMRT) is nowadays one of the treatment strategies for prostate cancer. There are few reports on planning study of prostate cancer by CyberKnife with respect to the urethral dose because of the invisibility in CT. We have investigated a planning method using fixed collimators with considering dose homogeneity, conformity and urethral dose. Methods: Radiotherapy treatment planning of prostate cancer were under a clinical trial approved by the institutional review board. The prescription dose of 35 Gy were delivered to the PTV in five fractions with the urethral catheter. Urethra position was identified by pretreatment CT and catheter, which was inserted before treatment planning CT and released after the treatment. All plans agreed to the criteria as shown in table 1, and the following constraints were recommended as well: the prescribed iso-dose line should be from 70% to 90%; the total MU should be below 50,000 MU; the minimum MU per beam should be larger than 15 MU; the estimated delivery time (excluding patient setup time) by Multiplan with image time interval of 60 s should be less than 35 min. Collimator size and position were decided as shown in figure 1. Fixed collimator of 15 mm was positioned around urethra and PTV for avoiding high dose of urethra and achieving conformity, and fixed collimator of 30 or 40 were positioned around PTV for achieving dose homogeneity. Results: With this method, all constraints were achieved. (Table 1, Figure 2) Max dose of urethra was ranging from 103.9% to 114.2%, because urethra position was identified by pretreatment CT and urethral catheter. Conclusion: Hypo-fractionated SBRT with IMRT utilizing urethral catheter could be a promising new treatment option for prostate cancer. This work was supported by JSPS Core-to-Core program Number 23003

  19. SU-E-T-767: Treatment Planning Study of Prostate Cancer by CyberKnife with Respect to the Urethral Dose

    Energy Technology Data Exchange (ETDEWEB)

    Mizuno, H; Mizuno, H; Sumida, I; Otani, Y; Yagi, M; Takashina, M; Suzuki, O; Yoshioka, Y; Koizumi, M; Ogawa, K [Osaka University, Suita, Osaka (Japan)

    2015-06-15

    Purpose: Hypo-fractionated stereotactic body radiation therapy (SBRT) with intensity modulated radiation therapy (IMRT) is nowadays one of the treatment strategies for prostate cancer. There are few reports on planning study of prostate cancer by CyberKnife with respect to the urethral dose because of the invisibility in CT. We have investigated a planning method using fixed collimators with considering dose homogeneity, conformity and urethral dose. Methods: Radiotherapy treatment planning of prostate cancer were under a clinical trial approved by the institutional review board. The prescription dose of 35 Gy were delivered to the PTV in five fractions with the urethral catheter. Urethra position was identified by pretreatment CT and catheter, which was inserted before treatment planning CT and released after the treatment. All plans agreed to the criteria as shown in table 1, and the following constraints were recommended as well: the prescribed iso-dose line should be from 70% to 90%; the total MU should be below 50,000 MU; the minimum MU per beam should be larger than 15 MU; the estimated delivery time (excluding patient setup time) by Multiplan with image time interval of 60 s should be less than 35 min. Collimator size and position were decided as shown in figure 1. Fixed collimator of 15 mm was positioned around urethra and PTV for avoiding high dose of urethra and achieving conformity, and fixed collimator of 30 or 40 were positioned around PTV for achieving dose homogeneity. Results: With this method, all constraints were achieved. (Table 1, Figure 2) Max dose of urethra was ranging from 103.9% to 114.2%, because urethra position was identified by pretreatment CT and urethral catheter. Conclusion: Hypo-fractionated SBRT with IMRT utilizing urethral catheter could be a promising new treatment option for prostate cancer. This work was supported by JSPS Core-to-Core program Number 23003.

  20. An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration

    International Nuclear Information System (INIS)

    Seo, Jung Min; Lee, Chang Yeol; Huh, Hyun Do; Kim, Wan Sun

    2015-01-01

    error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average 1.14 ± 0.13 mm, 1.05 ± 0.20 mm, with 2.37 ± 0.17 mm, suddenly for it is variations in breathing, respective average 1.87 ± 0.19 mm, 2.15 ± 0.21 mm, and analyzed with 2.44 ± 0.26 mm. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average 0.84 ± 0.01 mm, 0.70 ± 0.13 mm, with 1.63 ± 0.10 mm, if it is a variant of sudden breathing respective average 0.97 ± 0.06 mm, 1.44 ± 0.11 mm, and analyzed with 1.98 ± 0.10 mm. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the

  1. An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jung Min; Lee, Chang Yeol; Huh, Hyun Do; Kim, Wan Sun [Dept. of Radiation Oncology, Inha university hospital, Incheon (Korea, Republic of)

    2015-12-15

    error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average 1.14 ± 0.13 mm, 1.05 ± 0.20 mm, with 2.37 ± 0.17 mm, suddenly for it is variations in breathing, respective average 1.87 ± 0.19 mm, 2.15 ± 0.21 mm, and analyzed with 2.44 ± 0.26 mm. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average 0.84 ± 0.01 mm, 0.70 ± 0.13 mm, with 1.63 ± 0.10 mm, if it is a variant of sudden breathing respective average 0.97 ± 0.06 mm, 1.44 ± 0.11 mm, and analyzed with 1.98 ± 0.10 mm. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the

  2. Dose Calculation Accuracy of the Monte Carlo Algorithm for CyberKnife Compared with Other Commercially Available Dose Calculation Algorithms

    International Nuclear Information System (INIS)

    Sharma, Subhash; Ott, Joseph; Williams, Jamone; Dickow, Danny

    2011-01-01

    Monte Carlo dose calculation algorithms have the potential for greater accuracy than traditional model-based algorithms. This enhanced accuracy is particularly evident in regions of lateral scatter disequilibrium, which can develop during treatments incorporating small field sizes and low-density tissue. A heterogeneous slab phantom was used to evaluate the accuracy of several commercially available dose calculation algorithms, including Monte Carlo dose calculation for CyberKnife, Analytical Anisotropic Algorithm and Pencil Beam convolution for the Eclipse planning system, and convolution-superposition for the Xio planning system. The phantom accommodated slabs of varying density; comparisons between planned and measured dose distributions were accomplished with radiochromic film. The Monte Carlo algorithm provided the most accurate comparison between planned and measured dose distributions. In each phantom irradiation, the Monte Carlo predictions resulted in gamma analysis comparisons >97%, using acceptance criteria of 3% dose and 3-mm distance to agreement. In general, the gamma analysis comparisons for the other algorithms were <95%. The Monte Carlo dose calculation algorithm for CyberKnife provides more accurate dose distribution calculations in regions of lateral electron disequilibrium than commercially available model-based algorithms. This is primarily because of the ability of Monte Carlo algorithms to implicitly account for tissue heterogeneities, density scaling functions; and/or effective depth correction factors are not required.

  3. TH-AB-201-07: Filmless Treatment Localization QA for the CyberKnife System

    Energy Technology Data Exchange (ETDEWEB)

    Gersh, J [Gibbs Cancer Center & Research Institute - Pelham, Greer, SC (United States); Spectrum Medical Physics, LLC, Greenville, SC (United States); Noll, M [Accuray Incorporated, Sunnyvale, CA (United States)

    2016-06-15

    Purpose: Accuray recommends daily evaluation of the treatment localization and delivery systems (TLS/TDS) of the CyberKnife. The vendor-provided solution is a Winston-Lutz-type test that evaluates film shadows from an orthogonal beam pair (known as AQA). Since film-based techniques are inherently inefficient and potentially inconsistent and uncertain, this study explores a method which provides a comparable test with greater efficiency, consistency, and certainty. This test uses the QAStereoChecker (QASC, Standard Imaging, Inc., Middleton, WI), a high-resolution flat-panel detector with coupled fiducial markers for automated alignment. Fiducial tracking is used to achieve high translational and rotational position accuracy. Methods: A plan is generated delivering five circular beams, with varying orientation and angular incidence. Several numeric quantities are calculated for each beam: eccentricity, centroid location, area, major-axis length, minor-axis length, and orientation angle. Baseline values were acquired and repeatability of baselines analyzed. Next, errors were induced in the path calibration of the CK, and the test repeated. A correlative study was performed between the induced errors and quantities measured using the QASC. Based on vendor recommendations, this test should be able to detect a TLS/TDS offset of 0.5mm. Results: Centroid shifts correlated well with induced plane-perpendicular offsets (p < 0.01). Induced vertical shifts correlated best with the absolute average deviation of eccentricities (p < 0.05). The values of these metrics which correlated with the threshold of 0.5mm induced deviation were used as individual pass/fail criteria. These were then used to evaluate induced offsets which shifted the CK in all axes (a clinically-realistic offset), with a total offset of 0.5mm. This test provided high and specificity and sensitivity. Conclusion: From setup to analysis, this filmless TLS/TDS test requires 4 minutes, as opposed to 15–20

  4. TH-AB-201-07: Filmless Treatment Localization QA for the CyberKnife System

    International Nuclear Information System (INIS)

    Gersh, J; Noll, M

    2016-01-01

    Purpose: Accuray recommends daily evaluation of the treatment localization and delivery systems (TLS/TDS) of the CyberKnife. The vendor-provided solution is a Winston-Lutz-type test that evaluates film shadows from an orthogonal beam pair (known as AQA). Since film-based techniques are inherently inefficient and potentially inconsistent and uncertain, this study explores a method which provides a comparable test with greater efficiency, consistency, and certainty. This test uses the QAStereoChecker (QASC, Standard Imaging, Inc., Middleton, WI), a high-resolution flat-panel detector with coupled fiducial markers for automated alignment. Fiducial tracking is used to achieve high translational and rotational position accuracy. Methods: A plan is generated delivering five circular beams, with varying orientation and angular incidence. Several numeric quantities are calculated for each beam: eccentricity, centroid location, area, major-axis length, minor-axis length, and orientation angle. Baseline values were acquired and repeatability of baselines analyzed. Next, errors were induced in the path calibration of the CK, and the test repeated. A correlative study was performed between the induced errors and quantities measured using the QASC. Based on vendor recommendations, this test should be able to detect a TLS/TDS offset of 0.5mm. Results: Centroid shifts correlated well with induced plane-perpendicular offsets (p < 0.01). Induced vertical shifts correlated best with the absolute average deviation of eccentricities (p < 0.05). The values of these metrics which correlated with the threshold of 0.5mm induced deviation were used as individual pass/fail criteria. These were then used to evaluate induced offsets which shifted the CK in all axes (a clinically-realistic offset), with a total offset of 0.5mm. This test provided high and specificity and sensitivity. Conclusion: From setup to analysis, this filmless TLS/TDS test requires 4 minutes, as opposed to 15–20

  5. SU-F-T-554: Dark Current Effect On CyberKnife Beam Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H; Chang, A [Soonchunhyang University Hospital, Seoul (Korea, Republic of)

    2016-06-15

    Purpose: All RF linear accelerators produce dark current to varying degrees when an accelerating voltage and RF input is applied in the absence of electron gun injection. This study is to evaluate how dark current from the linear accelerator of CyberKnife affect the dose in the reference dosimetry. Methods: The G4 CyberKnife system with 6MV photon beam was used in this study. Using the ion chamber and the diode detector, the dose was measured in water with varying time delay between acquiring charges and staring beam-on after applying high-voltage into the linear accelerator. The dose was measured after the time delay with over the range of 0 to 120 seconds in the accelerating high-voltage mode without beam-on, applying 0, 10, 50, 100, and 200 MUs. For the measurements, the collimator of 60 mm was used and the detectors were placed at the depths of 10 cm with the source-to-surface distance of 80 cm. Results: The dark current was constant over time regardless of MU. The dose due to the dark current increased over time linearly with the R-squared value of 0.9983 up to 4.4 cGy for the time 120 seconds. In the dose rate setting of 720 MU/min, the relative dose when applying the accelerating voltage without beam-on was increased over time up to 0.6% but it was less than the leakage radiation resulted from the accelerated head. As the reference dosimetry condition, when 100 MU was delivered after 10 seconds time delay, the relative dose increased by 0.7% but 6.7% for the low MU (10 MU). Conclusion: In the dosimetry using CyberKnife system, the constant dark current affected to the dose. Although the time delay in the accelerating high-voltage mode without beam-on is within 10 seconds, the dose less than 100 cGy can be overestimated more than 1%.

  6. Evaluation of the peripheral dose in stereotactic radiotherapy and radiosurgery treatments

    Energy Technology Data Exchange (ETDEWEB)

    Di Betta, Erika; Fariselli, Laura; Bergantin, Achille; Locatelli, Federica; Del Vecchio, Antonella; Broggi, Sara; Fumagalli, Maria Luisa [Department of Neurosurgery, Division of Medical Physics, Fondazione IRCCS, Istituto Neurologico C. Besta, 20133 Milano (Italy); Department of Neurosurgery, Division of Radiotherapy, Fondazione IRCCS, Istituto Neurologico C. Besta, 20133 Milano (Italy); CyberKnife Centre, Centro Diagnostico Italiano, 20147 Milano (Italy); Division of Medical Physics, Fondazione IRCCS, Istituto S. Raffaele, 20132 Milano (Italy); Department of Neurosurgery, Division of Medical Physics, Fondazione IRCCS, Istituto Neurologico C. Besta, 20133 Milano (Italy)

    2010-07-15

    Purpose: The main purpose of this work was to compare peripheral doses absorbed during stereotactic treatment of a brain lesion delivered using different devices. These data were used to estimate the risk of stochastic effects. Methods: Treatment plans were created for an anthropomorphic phantom and delivered using a LINAC with stereotactic cones and a multileaf collimator, a CyberKnife system (before and after a supplemental shielding was applied), a TomoTherapy system, and a Gamma Knife unit. For each treatment, 5 Gy were prescribed to the target. Measurements were performed with thermoluminescent dosimeters inserted roughly in the position of the thyroid, sternum, upper lung, lower lung, and gonads. Results: Mean doses ranged from of 4.1 (Gamma Knife) to 62.8 mGy (LINAC with cones) in the thyroid, from 2.3 (TomoTherapy) to 30 mGy (preshielding CyberKnife) in the sternum, from 1.7 (TomoTherapy) to 20 mGy (preshielding CyberKnife) in the upper part of the lungs, from 0.98 (Gamma Knife) to 15 mGy (preshielding CyberKnife) in the lower part of the lungs, and between 0.3 (Gamma Knife) and 10 mGy (preshielding CyberKnife) in the gonads. Conclusions: The peripheral dose absorbed in the sites of interest with a 5 Gy fraction is low. Although the risk of adverse side effects calculated for 20 Gy delivered in 5 Gy fractions is negligible, in the interest of optimum patient radioprotection, further studies are needed to determine the weight of each contributor to the peripheral dose.

  7. Evaluation of the peripheral dose in stereotactic radiotherapy and radiosurgery treatments

    International Nuclear Information System (INIS)

    Di Betta, Erika; Fariselli, Laura; Bergantin, Achille; Locatelli, Federica; Del Vecchio, Antonella; Broggi, Sara; Fumagalli, Maria Luisa

    2010-01-01

    Purpose: The main purpose of this work was to compare peripheral doses absorbed during stereotactic treatment of a brain lesion delivered using different devices. These data were used to estimate the risk of stochastic effects. Methods: Treatment plans were created for an anthropomorphic phantom and delivered using a LINAC with stereotactic cones and a multileaf collimator, a CyberKnife system (before and after a supplemental shielding was applied), a TomoTherapy system, and a Gamma Knife unit. For each treatment, 5 Gy were prescribed to the target. Measurements were performed with thermoluminescent dosimeters inserted roughly in the position of the thyroid, sternum, upper lung, lower lung, and gonads. Results: Mean doses ranged from of 4.1 (Gamma Knife) to 62.8 mGy (LINAC with cones) in the thyroid, from 2.3 (TomoTherapy) to 30 mGy (preshielding CyberKnife) in the sternum, from 1.7 (TomoTherapy) to 20 mGy (preshielding CyberKnife) in the upper part of the lungs, from 0.98 (Gamma Knife) to 15 mGy (preshielding CyberKnife) in the lower part of the lungs, and between 0.3 (Gamma Knife) and 10 mGy (preshielding CyberKnife) in the gonads. Conclusions: The peripheral dose absorbed in the sites of interest with a 5 Gy fraction is low. Although the risk of adverse side effects calculated for 20 Gy delivered in 5 Gy fractions is negligible, in the interest of optimum patient radioprotection, further studies are needed to determine the weight of each contributor to the peripheral dose.

  8. Validation of a pretreatment delivery quality assurance method for the CyberKnife Synchrony system

    Energy Technology Data Exchange (ETDEWEB)

    Mastella, E., E-mail: edoardo.mastella@cnao.it [Medical Physics Unit, CNAO Foundation—National Centre for Oncological Hadron Therapy, Pavia I-27100, Italy and Medical Physics Unit, IEO—European Institute of Oncology, Milan I-20141 (Italy); Vigorito, S.; Rondi, E.; Cattani, F. [Medical Physics Unit, IEO—European Institute of Oncology, Milan I-20141 (Italy); Piperno, G.; Ferrari, A.; Strata, E.; Rozza, D. [Department of Radiation Oncology, IEO—European Institute of Oncology, Milan I-20141 (Italy); Jereczek-Fossa, B. A. [Department of Radiation Oncology, IEO—European Institute of Oncology, Milan I-20141, Italy and Department of Oncology and Hematology Oncology, University of Milan, Milan I-20122 (Italy)

    2016-08-15

    Purpose: To evaluate the geometric and dosimetric accuracies of the CyberKnife Synchrony respiratory tracking system (RTS) and to validate a method for pretreatment patient-specific delivery quality assurance (DQA). Methods: An EasyCube phantom was mounted on the ExacTrac gating phantom, which can move along the superior–inferior (SI) axis of a patient to simulate a moving target. The authors compared dynamic and static measurements. For each case, a Gafchromic EBT3 film was positioned between two slabs of the EasyCube, while a PinPoint ionization chamber was placed in the appropriate space. There were three steps to their evaluation: (1) the field size, the penumbra, and the symmetry of six secondary collimators were measured along the two main orthogonal axes. Dynamic measurements with deliberately simulated errors were also taken. (2) The delivered dose distributions (from step 1) were compared with the planned ones, using the gamma analysis method. The local gamma passing rates were evaluated using three acceptance criteria: 3% local dose difference (LDD)/3 mm, 2%LDD/2 mm, and 3%LDD/1 mm. (3) The DQA plans for six clinical patients were irradiated in different dynamic conditions, to give a total of 19 cases. The measured and planned dose distributions were evaluated with the same gamma-index criteria used in step 2 and the measured chamber doses were compared with the planned mean doses in the sensitive volume of the chamber. Results: (1) A very slight enlargement of the field size and of the penumbra was observed in the SI direction (on average <1 mm), in line with the overall average CyberKnife system error for tracking treatments. (2) Comparison between the planned and the correctly delivered dose distributions confirmed the dosimetric accuracy of the RTS for simple plans. The multicriteria gamma analysis was able to detect the simulated errors, proving the robustness of their method of analysis. (3) All of the DQA clinical plans passed the tests, both in

  9. A retrospective review of Cyberknife Stereotactic Body Radiotherapy for Adrenal Tumors (Primary and Metastatic: Winthrop University Hospital experience

    Directory of Open Access Journals (Sweden)

    Amishi eDesai

    2015-08-01

    Full Text Available The adrenal gland is a common site of cancer metastasis. Surgery remains a mainstay of treatment for solitary adrenal metastasis. For patients who cannot undergo surgery, radiation is an alternative option. Stereotactic body radiotherapy (SBRT is an ablative treatment option allowing larger doses to be delivered over a shorter period of time. In this study, we report on our experience with the use of SBRT to treat adrenal metastases using Cyberknife technology. We retrospectively reviewed, the Winthrop-University radiation oncology data base to identify 14 patients for whom SBRT was administered to treat malignant adrenal disease. Of the factors examined, the biologic equivalent dose (BED of radiation delivered was found to be the most important predictor of local adrenal tumor control. We conclude that CyberKnife-based SBRT is a safe, non-invasive modality that has broadened the therapeutic options for the treatment of isolated adrenal metastases.

  10. CyberKnife Radiosurgery in the Multimodal Management of Patients with Cushing Disease.

    Science.gov (United States)

    Moore, Justin M; Sala, Elisa; Amorin, Alvaro; Martinez, Hector; Bhowmik, Aprotim C; Chang, Steven D; Soltys, Scott G; Harsh, Griffith R; Katznelson, Laurence

    2018-04-01

    Surgery is the primary treatment for Cushing disease. When surgery is unsuccessful in normalizing hypercortisolism, adjuvant radiation, such as stereotactic radiosurgery, may be useful to improve biochemical control. This retrospective study included a cohort of consecutive patients treated with CyberKnife (CK) radiosurgery for active Cushing disease at Stanford Hospital and Clinics. As first-line treatment, all patients underwent transsphenoidal surgery with histologic demonstration of an adrenocorticotropic hormone-producing pituitary adenoma. CK was performed as adjuvant therapy for persistent or recurrent disease. The median time between surgery and CK was 14 ± 34 months. Before CK, median maximal diameter of tumors was 9 mm (range, 7-32 mm), with cavernous sinus invasion in all patients (100%) and abutment of the optic chiasm in 1 patient (14.2%). With an average follow-up of 55.4 months, normalization of hypercortisolism was achieved in 4 patients (57.1%): 2 patients (28.5%) achieved normalization of the hypothalamic-pituitary-adrenal axis without glucocorticoid replacement, and 2 patients developed hypoadrenalism (28.5%). The median time to biochemical remission was 12.5 months. Hypopituitarism occurred in only 1 patient (14.2%), and no patients had visual complications. Time between surgery and radiotherapy of Cushing disease, we demonstrate that CK is an effective treatment with rare complications. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. SU-F-T-576: Characterization of Two Dimensional Liquid Filled Detector Array(SRS 1000) in High Precision Cyberknife Robotic Radiosurgery System

    International Nuclear Information System (INIS)

    Muthukumaran, M; Manigandan, D; Murali, V; Chitra, S; Ganapathy, K; Vikraman, S

    2016-01-01

    Purpose: The aim of the study is to characterize a two dimensional liquid filled detector array SRS 1000 for routine QA in Cyberknife Robotic Radiosurgery system. Methods: SRS 1000 consists of 977 liquid filled ionization chambers and is designed to be used in small field SRS/SBRT techniques. The detector array has got two different spacial resolutions. Till field size of 5.5×5.5 cm the spacial resolution is 2.5mm (center to center) and after that till field size of 11 × 11 cm the spacial resolution is 5mm. The size of the detector is 2.3 × 2.3 0.5 mm with a volume of .003 cc. The CyberKnife Robotic Radiosurgery System is a frameless stereotactic radiosurgery system in which a LINAC is mounted on a robotic manipulator to deliver beams with a high sub millimeter accuracy. The SRS 1000’s MU linearity, stability, reproducibility in Cyberknife Robotic Radiosurgery system was measured and investigated. The output factors for fixed and IRIS collimators for all available collimators (5mm till 60 mm) was measured and compared with the measurement done with PTW pin-point ionization chamber. Results: The MU linearity was measured from 2 MU till 1000 MU for doserates in the range of 700cGy/min – 780 cGy/min and compared with the measurement done with pin point chamber The MU linearity was with in 3%. The detector arrays stability and reproducibility was excellent and was withinin 0.5% The measured output factors showed an agreement of better than 2% when compared with the measurements with pinpoint chamber for both fixed and IRIS collimators with all available field sizes. Conclusion: We have characterised PTW 1000 SRS as a precise and accurate measurement tool for routine QA of Cyberknife Robotic radiosurgery system.

  12. SU-F-T-576: Characterization of Two Dimensional Liquid Filled Detector Array(SRS 1000) in High Precision Cyberknife Robotic Radiosurgery System

    Energy Technology Data Exchange (ETDEWEB)

    Muthukumaran, M [Apollo Speciality Hospitals, Chennai, Tamil Nadu (India); Manigandan, D [Fortis Cancer Institute, Mohali, Punjab (India); Murali, V; Chitra, S; Ganapathy, K [Apollo Speciality Hospital, Chennai, Tamil Nadu (India); Vikraman, S [Jaypee Hospital – Radiation Onology, Noida, UTTAR PRADESH (India)

    2016-06-15

    Purpose: The aim of the study is to characterize a two dimensional liquid filled detector array SRS 1000 for routine QA in Cyberknife Robotic Radiosurgery system. Methods: SRS 1000 consists of 977 liquid filled ionization chambers and is designed to be used in small field SRS/SBRT techniques. The detector array has got two different spacial resolutions. Till field size of 5.5×5.5 cm the spacial resolution is 2.5mm (center to center) and after that till field size of 11 × 11 cm the spacial resolution is 5mm. The size of the detector is 2.3 × 2.3 0.5 mm with a volume of .003 cc. The CyberKnife Robotic Radiosurgery System is a frameless stereotactic radiosurgery system in which a LINAC is mounted on a robotic manipulator to deliver beams with a high sub millimeter accuracy. The SRS 1000’s MU linearity, stability, reproducibility in Cyberknife Robotic Radiosurgery system was measured and investigated. The output factors for fixed and IRIS collimators for all available collimators (5mm till 60 mm) was measured and compared with the measurement done with PTW pin-point ionization chamber. Results: The MU linearity was measured from 2 MU till 1000 MU for doserates in the range of 700cGy/min – 780 cGy/min and compared with the measurement done with pin point chamber The MU linearity was with in 3%. The detector arrays stability and reproducibility was excellent and was withinin 0.5% The measured output factors showed an agreement of better than 2% when compared with the measurements with pinpoint chamber for both fixed and IRIS collimators with all available field sizes. Conclusion: We have characterised PTW 1000 SRS as a precise and accurate measurement tool for routine QA of Cyberknife Robotic radiosurgery system.

  13. Verification of Accuracy of CyberKnife Tumor-tracking Radiation Therapy Using Patient-specific Lung Phantoms

    International Nuclear Information System (INIS)

    Jung, Jinhong; Song, Si Yeol; Yoon, Sang Min; Kwak, Jungwon; Yoon, KyoungJun; Choi, Wonsik; Jeong, Seong-Yun; Choi, Eun Kyung; Cho, Byungchul

    2015-01-01

    Purpose: To investigate the accuracy of the CyberKnife Xsight Lung Tracking System (XLTS) compared with that of a fiducial-based target tracking system (FTTS) using patient-specific lung phantoms. Methods and Materials: Three-dimensional printing technology was used to make individualized lung phantoms that closely mimicked the lung anatomy of actual patients. Based on planning computed tomographic data from 6 lung cancer patients who underwent stereotactic ablative radiation therapy using the CyberKnife, the volume above a certain Hounsfield unit (HU) was assigned as the structure to be filled uniformly with polylactic acid material by a 3-dimensional printer (3D Edison, Lokit, Korea). We evaluated the discrepancies between the measured and modeled target positions, representing the total tracking error, using 3 log files that were generated during each treatment for both the FTTS and the XLTS. We also analyzed the γ index between the film dose measured under the FTTS and XLTS. Results: The overall mean values and standard deviations of total tracking errors for the FTTS were 0.36 ± 0.39 mm, 0.15 ± 0.64 mm, and 0.15 ± 0.62 mm for the craniocaudal (CC), left–right (LR), and anteroposterior (AP) components, respectively. Those for the XLTS were 0.38 ± 0.54 mm, 0.13 ± 0.18 mm, and 0.14 ± 0.37 mm for the CC, LR, and AP components, respectively. The average of γ passing rates was 100% for the criteria of 3%, 3 mm; 99.6% for the criteria of 2%, 2 mm; and 86.8% for the criteria of 1%, 1 mm. Conclusions: The XLTS has segmentation accuracy comparable with that of the FTTS and small total tracking errors

  14. Verification of Accuracy of CyberKnife Tumor-tracking Radiation Therapy Using Patient-specific Lung Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jinhong [Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Department of Radiation Oncology, Kyung Hee University Medical Center, Kyung Hee University School of Medicine, Seoul (Korea, Republic of); Song, Si Yeol, E-mail: coocoori@gmail.com [Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Yoon, Sang Min; Kwak, Jungwon; Yoon, KyoungJun [Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Choi, Wonsik [Department of Radiation Oncology, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung (Korea, Republic of); Jeong, Seong-Yun [Asan Institute for Life Science, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Choi, Eun Kyung; Cho, Byungchul [Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2015-07-15

    Purpose: To investigate the accuracy of the CyberKnife Xsight Lung Tracking System (XLTS) compared with that of a fiducial-based target tracking system (FTTS) using patient-specific lung phantoms. Methods and Materials: Three-dimensional printing technology was used to make individualized lung phantoms that closely mimicked the lung anatomy of actual patients. Based on planning computed tomographic data from 6 lung cancer patients who underwent stereotactic ablative radiation therapy using the CyberKnife, the volume above a certain Hounsfield unit (HU) was assigned as the structure to be filled uniformly with polylactic acid material by a 3-dimensional printer (3D Edison, Lokit, Korea). We evaluated the discrepancies between the measured and modeled target positions, representing the total tracking error, using 3 log files that were generated during each treatment for both the FTTS and the XLTS. We also analyzed the γ index between the film dose measured under the FTTS and XLTS. Results: The overall mean values and standard deviations of total tracking errors for the FTTS were 0.36 ± 0.39 mm, 0.15 ± 0.64 mm, and 0.15 ± 0.62 mm for the craniocaudal (CC), left–right (LR), and anteroposterior (AP) components, respectively. Those for the XLTS were 0.38 ± 0.54 mm, 0.13 ± 0.18 mm, and 0.14 ± 0.37 mm for the CC, LR, and AP components, respectively. The average of γ passing rates was 100% for the criteria of 3%, 3 mm; 99.6% for the criteria of 2%, 2 mm; and 86.8% for the criteria of 1%, 1 mm. Conclusions: The XLTS has segmentation accuracy comparable with that of the FTTS and small total tracking errors.

  15. SU-E-J-64: Feasibility Study of Surgical Clips for Fiducial Tracking in CyberKnife System

    International Nuclear Information System (INIS)

    Lee, H; Yoon, J; Lee, E; Cho, S; Park, K; Choi, W; Baek, J; Keum, K; Koom, W

    2015-01-01

    Purpose: To investigate the ability of CyberKnife to track surgical clips used as fiducial markers. Methods: The Octavius 1000SRS detector and solid water (RW3) slab phantom were used with motion platform to evaluate the study. The RW3 slab phantom was set up to measure the dose distribution from coronal plane. It consists of 9 plates and the thickness of each plate is 10mm. Among them, one plate was attached with 3 surgical clips, which are orthogonally positioned on outer region of array. The length of attached clip was represented as 1cm on planning CT. The clip plate was placed on the 1000SRS detector and 3 slabs were stacked up on the plate to build the measuring depth. Below the detector, 5 slabs were set. The two-axis motion platform was programmed with 1D sinusoidal movement (20mm peak-to-peak, 3s period) toward superior/inferior and left/right directions to simulate target motion. During delivery, two clips were extracted by two X-ray imagers, which led to translational error correction only. Synchrony was also used for dynamic tracking. After the irradiation, the measured dose distribution of coronal plane was compared with the planar dose distribution calculated by the CyberKnife treatment planning system (Multiplan) for cross verification. The results were assessed by comparing the absolute Gamma (γ) index. Results: The dose distributions measured by the 1000SRS detector were in good agreements with those calculated by Multiplan. In the dosimetric comparison using γ-function criteria based on the distance-to-agreement of 3mm and the local dose difference of 3%, the passing rate with γ- parameter ≤1 was 91% in coronal plane. Conclusion: The surgical clips can be considered as new fiducials for robotic radiosurgery delivery by considering the target margin with less than 5mm

  16. SU-E-T-228: Liquid Ionisation Chamber Array and MicroDiamond Measurements with the CyberKnife System

    International Nuclear Information System (INIS)

    Poppinga, D; Looe, H; Stelljes, T; Poppe, B; Blanck, O; Harder, D

    2014-01-01

    Purpose: The aim of this study was to measure the dose profile and output factors with a CyberKnife accelerator using a TM60019 microDiamond detector and a 1000SRS liquid chamber array (both PTW Freiburg, Germany). Methods: An MP3 water phantom (PTW, Freiburg) was positioned along the robotic world coordinate system. The TM60019 detector was adjusted to the center of the according fields and the semiconductor axis was aligned with the beam direction. Profiles at 5cm water depth and SSD = 80 cm were measured along the robotic x axis and y axis for the cylindrical collimators of the CyberKnife (diameter 60, 50, 40, 30, 20, 15, 12.5, 10, 7.5 and 5mm). To determine the output factors the dose profile was measured at 0.1 mm steps around the field center to find the maximum dose value. The liquid chamber array (1000SRS) measurement was performed with the same setup, but with RW3 buildup. Results: The 1000SRS measurements closely conform with the TM60019 profile measurement in all profile regions and for all collimator sizes. The profile measurement is influenced by the almost equal spatial resolution of the TM60019 detector (radius of the sensitive area 1.1mm) and of the 1000SRS liquid chamber array (single chamber width 2.3mm). The measured dose profiles have not been corrected for this limited spatial resolution. Rather we purpose to consider that spatial dose averaging over 2 mm wide regions might be justified in view of patient positioning inaccuracies and of the spaces in tissue participating in the biological radiation responses. Conclusion: The 1000SRS data points conform with the TM60019 profile measurements at all profile regions showing the applicability of liquid ion chamber arrays with the CyberKnife system

  17. SU-E-T-228: Liquid Ionisation Chamber Array and MicroDiamond Measurements with the CyberKnife System

    Energy Technology Data Exchange (ETDEWEB)

    Poppinga, D; Looe, H; Stelljes, T; Poppe, B [University of Oldenburg, Oldenburg, Lower Saxony (Germany); Blanck, O [CyberKnife Zentrum Norddeutschland, Guestrow (Germany); Harder, D [Georg August University, Goettingen, Niedersachsen (Germany)

    2014-06-01

    Purpose: The aim of this study was to measure the dose profile and output factors with a CyberKnife accelerator using a TM60019 microDiamond detector and a 1000SRS liquid chamber array (both PTW Freiburg, Germany). Methods: An MP3 water phantom (PTW, Freiburg) was positioned along the robotic world coordinate system. The TM60019 detector was adjusted to the center of the according fields and the semiconductor axis was aligned with the beam direction. Profiles at 5cm water depth and SSD = 80 cm were measured along the robotic x axis and y axis for the cylindrical collimators of the CyberKnife (diameter 60, 50, 40, 30, 20, 15, 12.5, 10, 7.5 and 5mm). To determine the output factors the dose profile was measured at 0.1 mm steps around the field center to find the maximum dose value. The liquid chamber array (1000SRS) measurement was performed with the same setup, but with RW3 buildup. Results: The 1000SRS measurements closely conform with the TM60019 profile measurement in all profile regions and for all collimator sizes. The profile measurement is influenced by the almost equal spatial resolution of the TM60019 detector (radius of the sensitive area 1.1mm) and of the 1000SRS liquid chamber array (single chamber width 2.3mm). The measured dose profiles have not been corrected for this limited spatial resolution. Rather we purpose to consider that spatial dose averaging over 2 mm wide regions might be justified in view of patient positioning inaccuracies and of the spaces in tissue participating in the biological radiation responses. Conclusion: The 1000SRS data points conform with the TM60019 profile measurements at all profile regions showing the applicability of liquid ion chamber arrays with the CyberKnife system.

  18. Fiducial-free CyberKnife stereotactic body radiation therapy (SBRT) for single vertebral body metastases: acceptable local control and normal tissue tolerance with 5 fraction approach

    Energy Technology Data Exchange (ETDEWEB)

    Gill, Beant; Oermann, Eric; Ju, Andrew; Suy, Simeng; Yu, Xia; Rabin, Jennifer [Department of Radiation Medicine, Georgetown University Hospital,, Washington, DC (United States); Kalhorn, Christopher; Nair, Mani N.; Voyadzis, Jean-Marc [Department of Neurosurgery, Georgetown University Hospital,, Washington, DC (United States); Unger, Keith; Collins, Sean P.; Harter, K. W.; Collins, Brian T., E-mail: collinsb@gunet.georgetown.edu [Department of Radiation Medicine, Georgetown University Hospital,, Washington, DC (United States)

    2012-04-26

    This retrospective analysis examines the local control and toxicity of five-fraction fiducial-free CyberKnife stereotactic body radiation therapy (SBRT) for single vertebral body (VB) metastases. All patients had favorable performance status (ECOG 0–1), oligometastatic disease, and no prior spine irradiation. A prescribed dose of 30–35 Gy was delivered in five fractions to the planning target volume (PTV) using the CyberKnife with X-sight spine tracking. Suggested maximum spinal cord and esophagus point doses were 30 and 40 Gy, respectively. A median 30 Gy (IQR, 30–35 Gy) dose was delivered to a median prescription isodose line of 70% (IQR, 65–77%) to 20 patients. At 34 months median follow-up (IQR, 25–40 months) for surviving patients, the 1- and 2-year Kaplan–Meier local control estimates were 80 and 73%, respectively. Two of the five local failures were infield in patients who had received irradiation to the gross tumor volume and three were paravertebral failures just outside the PTV in patients with prior corpectomy. No local failures occurred in patients who completed VB radiation alone. The 1- and 2-year Kaplan–Meier overall survival estimates were 80 and 57%, respectively. Most deaths were attributed to metastatic disease; one death was attributed to local recurrence. The mean maximum point doses were 26.4 Gy (SD, 5.1 Gy) to the spinal cord and 29.1 Gy (SD, 8.9 Gy) to the esophagus. Patients receiving maximum esophagus point doses greater than 35 Gy experienced acute dysphagia (Grade I/II). No spinal cord toxicity was documented. Five-fraction fiducial-free CyberKnife SBRT is an acceptable treatment option for newly diagnosed VB metastases with promising local control rates and minimal toxicity despite the close proximity of such tumors to the spinal cord and esophagus. A prospective study aimed at further enhancing local control by targeting the intact VB and escalating the total dose is planned.

  19. Dose linearity and monitor unit stability of a G4 type cyberknife robotic stereotactic radiosurgery system

    International Nuclear Information System (INIS)

    Sudahar, H.; Kurup, P.G.G.; Murali, V.; Velmurugan, J.

    2012-01-01

    Dose linearity studies on conventional linear accelerators show a linearity error at low monitor units (MUs). The purpose of this study was to establish the dose linearity and MU stability characteristics of a cyberknife (Accuracy Inc., USA) stereotactic radiosurgery system. Measurements were done at a depth of 5 cm in a stereotactic dose verification phantom with a source to surface distance of 75 cm in a Generation 4 (G4) type cyberknife system. All the 12 fixed-type collimators starting from 5 to 60 mm were used for the dose linearity study. The dose linearity was examined in small (1-10), medium (15-100) and large (125-1000) MU ranges. The MU stability test was performed with 60 mm collimator for 10 MU and 20 MU with different combinations. The maximum dose linearity error of -38.8% was observed for 1 MU with 5 mm collimator. Dose linearity error in the small MU range was considerably higher than in the medium and large MU ranges. The maximum error in the medium range was -2.4%. In the large MU range, the linearity error varied between -0.7% and 1.2%. The maximum deviation in the MU stability was -3.03%. (author)

  20. SU-F-T-598: Robotic Radiosurgery System Versus Pencil Beam Scanning Proton Therapy for Definitive Intracranial Treatments

    International Nuclear Information System (INIS)

    Lin, M; Pompos, A; Gu, X; Yan, Y; Abdulrahman, R; Timmerman, R; Jiang, S

    2016-01-01

    Purpose: To characterize the dose distributions of Cyberknife and intensity-modulated-proton-therapy (IMPT). Methods: A total of 20 patients previously treated with Cyberknife were selected. The original planning-target-volume (PTV) was used in the ‘IMPT-ideal’ plan assuming a comparable image-guidance with Cyberknife. A 3mm expansion was made to create the proton-PTV for the ‘IMPT-3mm’ plan representing the current proton-therapy where a margin of 3mm is used to account for the inferior image-guidance. The proton range uncertainty was taken-care in beam-design by adding the proximal- and distal-margins (3%water-equivalent-depth+1mm) for both proton plans. The IMPT plans were generated to meet the same target coverage as the Cyberknife-plans. The plan quality of IMPT-ideal and IMPT-3mm were compared to the Cyberknife-plan. To characterize plan quality, we defined the ratio(R) of volumes encompassed by the selected isodose surfaces for Cyberknife and IMPT plans (VCK/VIMPT). Comparisons were made for both Cyberknife versus IMPT-ideal and Cyberknife versusIMPT-3mm to further discuss the impact of setup error margins used in proton therapy and the correlation with target size and location. Results: IMPT-ideal plans yield comparable plan quality as CK plans and slightly better OAR sparing while the IMPT-3mm plan results in a higher dose to the OARs, especially for centralized tumors. Comparing to the IMPT-ideal plans, a slightly larger 80% (Ravg=1.05) dose cloud and significantly larger 50% (Ravg=1.3) and 20% (Ravg=1.60) dose clouds are seen in CK plans. However, the 3mm expansion results in a larger high and medium dose clouds in IMPT-3mm plans (Ravg=0.65 for 80%-isodose; Ravg=0.93 for 50%-isodose). The trend increases with the size of the target and the distance from the brainstem to the center of target. Conclusion: Cyberknife is more preferable for treating centralized targets and proton therapy is advantageous for the large and peripheral targets. Advanced

  1. SU-F-T-598: Robotic Radiosurgery System Versus Pencil Beam Scanning Proton Therapy for Definitive Intracranial Treatments

    Energy Technology Data Exchange (ETDEWEB)

    Lin, M; Pompos, A; Gu, X; Yan, Y; Abdulrahman, R; Timmerman, R; Jiang, S [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: To characterize the dose distributions of Cyberknife and intensity-modulated-proton-therapy (IMPT). Methods: A total of 20 patients previously treated with Cyberknife were selected. The original planning-target-volume (PTV) was used in the ‘IMPT-ideal’ plan assuming a comparable image-guidance with Cyberknife. A 3mm expansion was made to create the proton-PTV for the ‘IMPT-3mm’ plan representing the current proton-therapy where a margin of 3mm is used to account for the inferior image-guidance. The proton range uncertainty was taken-care in beam-design by adding the proximal- and distal-margins (3%water-equivalent-depth+1mm) for both proton plans. The IMPT plans were generated to meet the same target coverage as the Cyberknife-plans. The plan quality of IMPT-ideal and IMPT-3mm were compared to the Cyberknife-plan. To characterize plan quality, we defined the ratio(R) of volumes encompassed by the selected isodose surfaces for Cyberknife and IMPT plans (VCK/VIMPT). Comparisons were made for both Cyberknife versus IMPT-ideal and Cyberknife versusIMPT-3mm to further discuss the impact of setup error margins used in proton therapy and the correlation with target size and location. Results: IMPT-ideal plans yield comparable plan quality as CK plans and slightly better OAR sparing while the IMPT-3mm plan results in a higher dose to the OARs, especially for centralized tumors. Comparing to the IMPT-ideal plans, a slightly larger 80% (Ravg=1.05) dose cloud and significantly larger 50% (Ravg=1.3) and 20% (Ravg=1.60) dose clouds are seen in CK plans. However, the 3mm expansion results in a larger high and medium dose clouds in IMPT-3mm plans (Ravg=0.65 for 80%-isodose; Ravg=0.93 for 50%-isodose). The trend increases with the size of the target and the distance from the brainstem to the center of target. Conclusion: Cyberknife is more preferable for treating centralized targets and proton therapy is advantageous for the large and peripheral targets. Advanced

  2. Independent Monte-Carlo dose calculation for MLC based CyberKnife radiotherapy

    Science.gov (United States)

    Mackeprang, P.-H.; Vuong, D.; Volken, W.; Henzen, D.; Schmidhalter, D.; Malthaner, M.; Mueller, S.; Frei, D.; Stampanoni, M. F. M.; Dal Pra, A.; Aebersold, D. M.; Fix, M. K.; Manser, P.

    2018-01-01

    This work aims to develop, implement and validate a Monte Carlo (MC)-based independent dose calculation (IDC) framework to perform patient-specific quality assurance (QA) for multi-leaf collimator (MLC)-based CyberKnife® (Accuray Inc., Sunnyvale, CA) treatment plans. The IDC framework uses an XML-format treatment plan as exported from the treatment planning system (TPS) and DICOM format patient CT data, an MC beam model using phase spaces, CyberKnife MLC beam modifier transport using the EGS++ class library, a beam sampling and coordinate transformation engine and dose scoring using DOSXYZnrc. The framework is validated against dose profiles and depth dose curves of single beams with varying field sizes in a water tank in units of cGy/Monitor Unit and against a 2D dose distribution of a full prostate treatment plan measured with Gafchromic EBT3 (Ashland Advanced Materials, Bridgewater, NJ) film in a homogeneous water-equivalent slab phantom. The film measurement is compared to IDC results by gamma analysis using 2% (global)/2 mm criteria. Further, the dose distribution of the clinical treatment plan in the patient CT is compared to TPS calculation by gamma analysis using the same criteria. Dose profiles from IDC calculation in a homogeneous water phantom agree within 2.3% of the global max dose or 1 mm distance to agreement to measurements for all except the smallest field size. Comparing the film measurement to calculated dose, 99.9% of all voxels pass gamma analysis, comparing dose calculated by the IDC framework to TPS calculated dose for the clinical prostate plan shows 99.0% passing rate. IDC calculated dose is found to be up to 5.6% lower than dose calculated by the TPS in this case near metal fiducial markers. An MC-based modular IDC framework was successfully developed, implemented and validated against measurements and is now available to perform patient-specific QA by IDC.

  3. Continuous versus step-by-step scanning mode of a novel 3D scanner for CyberKnife measurements

    International Nuclear Information System (INIS)

    Al Kafi, M Abdullah; Mwidu, Umar; Moftah, Belal

    2015-01-01

    The purpose of the study is to investigate the continuous versus step-by-step scanning mode of a commercial circular 3D scanner for commissioning measurements of a robotic stereotactic radiosurgery system. The 3D scanner was used for profile measurements in step-by-step and continuous modes with the intent of comparing the two scanning modes for consistency. The profile measurements of in-plane, cross-plane, 15 degree, and 105 degree were performed for both fixed cones and Iris collimators at depth of maximum dose and at 10 cm depth. For CyberKnife field size, penumbra, flatness and symmetry analysis, it was observed that the measurements with continuous mode, which can be up to 6 times faster than step-by-step mode, are comparable and produce scans nearly identical to step-by-step mode. When compared with centered step-by-step mode data, a fully processed continuous mode data gives rise to maximum of 0.50% and 0.60% symmetry and flatness difference respectfully for all the fixed cones and Iris collimators studied. - Highlights: • D scanner for CyberKnife beam data measurements. • Beam data analysis for continuous and step-by-step scan modes. • Faster continuous scanning data are comparable to step-by-step mode scan data.

  4. Determination of small field synthetic single-crystal diamond detector correction factors for CyberKnife, Leksell Gamma Knife Perfexion and linear accelerator.

    Science.gov (United States)

    Veselsky, T; Novotny, J; Pastykova, V; Koniarova, I

    2017-12-01

    The aim of this study was to determine small field correction factors for a synthetic single-crystal diamond detector (PTW microDiamond) for routine use in clinical dosimetric measurements. Correction factors following small field Alfonso formalism were calculated by comparison of PTW microDiamond measured ratio M Qclin fclin /M Qmsr fmsr with Monte Carlo (MC) based field output factors Ω Qclin,Qmsr fclin,fmsr determined using Dosimetry Diode E or with MC simulation itself. Diode measurements were used for the CyberKnife and Varian Clinac 2100C/D linear accelerator. PTW microDiamond correction factors for Leksell Gamma Knife (LGK) were derived using MC simulated reference values from the manufacturer. PTW microDiamond correction factors for CyberKnife field sizes 25-5 mm were mostly smaller than 1% (except for 2.9% for 5 mm Iris field and 1.4% for 7.5 mm fixed cone field). The correction of 0.1% and 2.0% for 8 mm and 4 mm collimators, respectively, needed to be applied to PTW microDiamond measurements for LGK Perfexion. Finally, PTW microDiamond M Qclin fclin /M Qmsr fmsr for the linear accelerator varied from MC corrected Dosimetry Diode data by less than 0.5% (except for 1 × 1 cm 2 field size with 1.3% deviation). Regarding low resulting correction factor values, the PTW microDiamond detector may be considered an almost ideal tool for relative small field dosimetry in a large variety of stereotactic and radiosurgery treatment devices. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  5. The safety and efficacy of robotic image-guided radiosurgery system treatment for intra- and extracranial lesions: A systematic review of the literature

    International Nuclear Information System (INIS)

    Calcerrada Diaz-Santos, Nieves; Blasco Amaro, Juan Antonio; Cardiel, Gloria Ariza; Andradas Aragones, Elena

    2008-01-01

    Background: The CyberKnife is a new, frameless stereotactic radiosurgery system. This work reviews its safety and efficacy in the treatment of intra- and extracranial lesions. Methods: A literature search was made of the Medline, Embase, Pascal Biomed, CINAHL and Cancerlit databases. Health technology assessment reports on stereotactic radiosurgery systems were also consulted. All searches were made in June 2007. Data on efficacy and safety were extracted and then synthesized into the present review. Results: Thirty five clinical studies were identified, the majority of which included no patient comparison group. These studies assessed the use of the CyberKnife mainly in the treatment of primary and metastatic intracranial and spinal tumours. Conclusions: The CyberKnife system allows to carry out standard radiosurgical and fractionated stereotactic radiotherapy procedures. The use of this system offers an alternative for the treatment of inoperable tumours, and of lesions located close to critical structures that cannot be treated using other types of stereotactic radiosurgery system. Unfortunately, the quality of the reviewed papers still does not allow definite conclusions to be drawn regarding the safety and efficacy of these treatments

  6. SU-E-T-797: Variations of Cardiac Dose at Different Respiratory Status in CyberKnife M6â„¢ Treatment Plans for Accelerated Partial Breast Irradiation (APBI)

    Energy Technology Data Exchange (ETDEWEB)

    Long, S [Florida Atlantic University, Boca Raton, FL (United States); Shang, C [Boca Raton Regional Hospital, Boca Raton, FL (United States); Evans, G [Boca Raton, FL (United States); Leventouri, T [FAU, Boca Raton, FL (United States)

    2015-06-15

    Purpose: Cyberknife robotic assisted radiation delivery has become a choice for accelerated breast RT, while a slightly increased cardiac dose has been reported. The dose dynamics throughout the respiration cycle has scarcely been explored. This study was designed to investigate the dose changes at each respiratory phase or status during respiration cycle. Methods: Six patients with 4DCT studies and six patients with a pair of free-breathing and deep breath-hold CT sets were used for dosimetry comparisons. 4DCT sets were obtained by Siemens™ CT and its respiratory gating system, comprising of 8 phases. Standard APBI plan at 340 cGy was done per fraction per NSABP B-39/RTOG 0413 and modulated with Cyberknife M6™ on MultiPlan™5.1.2. For the purpose of this study, the tumor volume was outlined in the media-lower quadrant of the left breast. Results: Except for D5cc in plans with 4DCT, cardiac doses are significantly different between respiratory phases in well inhaled breathing phases, and more significantly in plans with BH CT. Mean cardiac doses in 100% inhalation phase were often found to be 5–15% (p< 0.02) less than those in other phases. Conclusion: Although ineligible cardiac doses are noted in APBI plans using 4D free-breathing CT and instantaneous free breathing CT series, a reduction in cardiac dose was seen for the well-inhaled phases. This provides practical guidance for cardiac dose reduction applicable with CK M6 APBR.

  7. SU-E-T-797: Variations of Cardiac Dose at Different Respiratory Status in CyberKnife M6â„¢ Treatment Plans for Accelerated Partial Breast Irradiation (APBI)

    International Nuclear Information System (INIS)

    Long, S; Shang, C; Evans, G; Leventouri, T

    2015-01-01

    Purpose: Cyberknife robotic assisted radiation delivery has become a choice for accelerated breast RT, while a slightly increased cardiac dose has been reported. The dose dynamics throughout the respiration cycle has scarcely been explored. This study was designed to investigate the dose changes at each respiratory phase or status during respiration cycle. Methods: Six patients with 4DCT studies and six patients with a pair of free-breathing and deep breath-hold CT sets were used for dosimetry comparisons. 4DCT sets were obtained by Siemens™ CT and its respiratory gating system, comprising of 8 phases. Standard APBI plan at 340 cGy was done per fraction per NSABP B-39/RTOG 0413 and modulated with Cyberknife M6™ on MultiPlan™5.1.2. For the purpose of this study, the tumor volume was outlined in the media-lower quadrant of the left breast. Results: Except for D5cc in plans with 4DCT, cardiac doses are significantly different between respiratory phases in well inhaled breathing phases, and more significantly in plans with BH CT. Mean cardiac doses in 100% inhalation phase were often found to be 5–15% (p< 0.02) less than those in other phases. Conclusion: Although ineligible cardiac doses are noted in APBI plans using 4D free-breathing CT and instantaneous free breathing CT series, a reduction in cardiac dose was seen for the well-inhaled phases. This provides practical guidance for cardiac dose reduction applicable with CK M6 APBR

  8. SU-E-T-382: Evaluation of Clinical Application and Dosimetric Comparison for Treatment Plans of Gamma Knife and CyberKnife for Arteriovenous Malformations

    Energy Technology Data Exchange (ETDEWEB)

    Kuo, C [Department of Radiation Oncology, Shuang Ho Hospital, Taipei Medical Univer, New Taipei City, Taiwan (R.O.C.) (China)

    2015-06-15

    Purpose: To analyze and compare the characteristics of dose distributions between Gamma Knife (GK) and CyberKnife (CK), in treating arteriovenous malformations (AVMs), and evaluate the influences on their clinical applications. Methods: Twenty four patients with AVMs treated with CK of prescribed dose (PD) of 16–25 Gy in single fraction were selected. Each patient’s CT images used for CK treatment planning with contours of targets and critical organs were exported and then loaded into the GK planning system. GK treatment plan with the same PD used in CK was generated for each patient. The metrics for dose comparison between GK and CK included conformity index (CI), gradient index (GI) of 75%, 50% and 25% of the PD, heterogeneity index (HI), volume of brain tissues covered by 10 Gy and 12 Gy, maximum dose to brainstem and beam-on time. Paired Samples t-test was used to analyze these metrics for significance (p value). Results: The CI were 0.744 ± 0.075 (GK) and 0.768 ± 0.086 (CK), p = 0.281. The GI75%, GI50%, and GI25% in GK and CK were 1.735 ± 0.100 and 2.439 ± 0.338 (p < 0.001), 3.169 ± 0.265 and 4.972 ± 0.852 (p < 0.001), and 8.650 ± 0.914 and 14.261 ± 2.476 (p < 0.001). The HI were 0.728 ± 0.072 (GK) and 0.313 ± 0.069 (CK), p < 0.001. There were significant differences both for volume of brain tissues covered by 10 Gy and 12 Gy in GK and CK (p < 0.001). GK had smaller maximum dose to brainstem. CK had shorter beam-on time. Conclusion: GK has similar dose conformity as CK, and has better normal tissue sparing but is less efficient than CK.

  9. SU-E-T-382: Evaluation of Clinical Application and Dosimetric Comparison for Treatment Plans of Gamma Knife and CyberKnife for Arteriovenous Malformations

    International Nuclear Information System (INIS)

    Kuo, C

    2015-01-01

    Purpose: To analyze and compare the characteristics of dose distributions between Gamma Knife (GK) and CyberKnife (CK), in treating arteriovenous malformations (AVMs), and evaluate the influences on their clinical applications. Methods: Twenty four patients with AVMs treated with CK of prescribed dose (PD) of 16–25 Gy in single fraction were selected. Each patient’s CT images used for CK treatment planning with contours of targets and critical organs were exported and then loaded into the GK planning system. GK treatment plan with the same PD used in CK was generated for each patient. The metrics for dose comparison between GK and CK included conformity index (CI), gradient index (GI) of 75%, 50% and 25% of the PD, heterogeneity index (HI), volume of brain tissues covered by 10 Gy and 12 Gy, maximum dose to brainstem and beam-on time. Paired Samples t-test was used to analyze these metrics for significance (p value). Results: The CI were 0.744 ± 0.075 (GK) and 0.768 ± 0.086 (CK), p = 0.281. The GI75%, GI50%, and GI25% in GK and CK were 1.735 ± 0.100 and 2.439 ± 0.338 (p < 0.001), 3.169 ± 0.265 and 4.972 ± 0.852 (p < 0.001), and 8.650 ± 0.914 and 14.261 ± 2.476 (p < 0.001). The HI were 0.728 ± 0.072 (GK) and 0.313 ± 0.069 (CK), p < 0.001. There were significant differences both for volume of brain tissues covered by 10 Gy and 12 Gy in GK and CK (p < 0.001). GK had smaller maximum dose to brainstem. CK had shorter beam-on time. Conclusion: GK has similar dose conformity as CK, and has better normal tissue sparing but is less efficient than CK

  10. Cyberknife Relative Output Factor measurements using fiber-coupled luminescence, MOSFETS and RADPOS dosimetry system

    DEFF Research Database (Denmark)

    Ploquin, N.; Kertzscher Schwencke, Gustavo Adolfo Vladimir; Vandervoort, E.

    2012-01-01

    from 5 to 60 mm. ROFs were also measured using a mobileMOSFET system (Best Medical Canada) and EBT1 and EBT2 GAFCHROMIC® (ISP, Ashland) radiochromic films. For cone sizes 12.5–60 mm all detector results were in agreement within the measurement uncertainty. The microMOSFET/RADPOS measurements (published.......3% and 0.865 ± 0.3% for 5, 7.5 and 10 mm cones. Our study shows that the microMOSFET/RADPOS and optical fiber‐coupled RL dosimetry system are well suited for Cyberknife cone output factors measurements over the entire range of field sizes, provided that appropriate correction factors are applied...

  11. Calculation of beam quality correction factor using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Kawachi, T.; Saitoh, H.; Myojoyama, A.; Katayose, T.; Kojima, T.; Fukuda, K.; Inoue, M.

    2005-01-01

    In recent years, a number of the CyberKnife systems (Accuray C., U.S.) have been increasing significantly. However, the CyberKnife has unique treatment head structure and beam collimating system. Therefore, the global standard protocols can not be adopted for absolute absorbed dose dosimetry in CyberKnife beam. In this work, the energy spectrum of photon and electron from CyberKnife treatment head at 80 cm SSD and several depths in water are simulated with conscientious geometry using by the EGS Monte Carlo method. Furthermore, for calculation of the beam quality correction factor k Q , the mean restricted mass stopping power and the mass energy absorption coefficient of air, water and several chamber wall and waterproofing sleeve materials are calculated. As a result, the factors k Q CyberKnife beam for several ionization chambers are determined. And the relationship between the beam quality index PDD(10) x in CyberKnife beam and k Q is described in this report. (author)

  12. Pain relief by Cyberknife radiosurgery for spinal metastasis.

    Science.gov (United States)

    Lee, Sunyoung; Chun, Mison

    2012-01-01

    To report pain relief effect in patients with spinal metastases treated with Cyberknife® and to analyze the factors associated with pain relapse after initial pain relief. We retrospectively analyzed patients with spinal metastasis treated with stereotactic body radiosurgery between April 2007 and June 2009. A total of 57 patients with 73 lesions were available for analysis with a median follow-up of 6.8 months (range, 1-30). Pain was assessed by a verbal/visual analogue scale at each visit: from 0 to 10. Pain relief was defined as a decrease of at least three levels of the pain score without an increase in analgesic use. Complete relief was defined as no analgesics or a score 0 or 1. Pain relief was achieved in 88% of the lesions, with complete relief in 51% within 7 days from the start of radiosurgery. The median duration of pain relief was 3.2 months (range, 1-30). Pain reappeared in 16 patients (27%). Spinal cord compression (P = 0.001) and performance status (P = 0.01) were predictive of pain relapse by multivariate Cox analysis. All 6 patients treated with solitary spinal metastasis experienced pain relief; 5 of them were alive without evidence of disease at a median of 16 months (range, 7-30). As previous studies have shown, our study confirms that pain relief with spinal radiosurgery is around 90%. In particular, long-term pain relief and disease control was observed in patients with solitary spinal metastasis.

  13. Carotid blowout syndrome in pharyngeal cancer patients treated by hypofractionated stereotactic re-irradiation using CyberKnife: A multi-institutional matched-cohort analysis

    International Nuclear Information System (INIS)

    Yamazaki, Hideya; Ogita, Mikio; Himei, Kengo; Nakamura, Satoaki; Kotsuma, Tadayuki; Yoshida, Ken; Yoshioka, Yasuo

    2015-01-01

    Background and purpose: Although reirradiation has attracted attention as a potential therapy for recurrent head and neck tumors with the advent of modern radiotherapy, severe rate toxicity such as carotid blowout syndrome (CBOS) limits its potential. The aim of this study was to identify the risk factors of CBOS after hypofractionated stereotactic radiotherapy (SBRT). Methods and patients: We conducted a matched-pair design examination of pharyngeal cancer patients treated by CyberKnife reirradiation in four institutes. Twelve cases with CBOS were observed per 60 cases without CBOS cases. Prognostic factors for CBOS were analyzed and a risk classification model was constructed. Results: The median prescribed radiation dose was 30 Gy in 5 fractions with CyberKnife SBRT after 60 Gy/30 fractions of previous radiotherapy. The median duration between reirradiation and CBOS onset was 5 months (range, 0–69 months). CBOS cases showed a median survival time of 5.5 months compared to 22.8 months for non-CBOS cases (1-year survival rate, 36% vs.72%; p = 0.003). Univariate analysis identified an angle of carotid invasion of >180°, the presence of ulceration, planning treatment volume, and irradiation to lymph node areas as statistically significant predisposing factors for CBOS. Only patients with carotid invasion of >180° developed CBOS (12/50, 24%), whereas no patient with tumor involvement less than a half semicircle around the carotid artery developed CBOS (0/22, 0%, p = 0.03). Multivariate Cox hazard model analysis revealed that the presence of ulceration and irradiation to lymph nodes were statistically significant predisposing factors. Thus, we constructed a CBOS risk classification system: CBOS index = (summation of risk factors; carotid invasion >180°, presence of ulceration, lymph node area irradiation). This system sufficiently separated the risk groups. Conclusion: The presence of ulceration and lymph node irradiation are risk factors of CBOS. The CBOS index

  14. Fractionated stereotactic radiotherapy as a boost treatment for tumors in the head and neck region

    International Nuclear Information System (INIS)

    Uno, Takashi; Isobe, Kouichi; Ueno, Naoyuki; Ito, Hisao; Fukuda, Ataru; Sudo, Satoshi; Shirotori, Hiroaki; Kitahara, Isao; Fukushima, Takanori

    2010-01-01

    The objective of this retrospective study was to report initial results of CyberKnife stereotactic radiotherapy (SRT) boost for tumors in the head and neck area. Between March 2008 and August 2009, 10 patients were treated with SRT boost using CyberKnife system due mainly to unfavorable condition such as tumors in close proximity to serial organs or former radiotherapy fields. Treatment sites were the external auditory canal in two, the nasopharynx in one, the oropharynx in three, the nasal cavity in one, the maxillary sinus in two, and the oligometastatic cervical lymph node in one. All patients underwent preceding conventional radiotherapy of 40 to 60 Gy. Dose and fractionation scheme of the Cyberknife SRT boost was individualized, and prescribed dose ranged from 9 Gy to 16 Gy in 3 to 4 fractions. Among four patients for whom dose to the optic pathway was concerned, the maximum dose was only about 3 Gy for three patients whereas 9.6 Gy in the remaining one patient. The maximum dose for the mandible in one of three patients with oropharyngeal cancer was 19.7 Gy, whereas majority of the bone can be spared by using non-isocentric conformal beams. For a patient with nasopharyngeal cancer, the highest dose in the brain stem was 15 Gy. However, majority of the brain stem received less than 40% of the maximum dose. Although a small volume high dose area within the normal structure could be observed in several patients, results of the present study showed potential benefits of the CyberKnife SRT boost. (author)

  15. CyberKnife : kirjallisuuskatsaus sädehoitolaitteesta ja sen käyttökohteista syövän ja muiden sairauksien hoidossa

    OpenAIRE

    Sormunen, Santtu; Laaksoranta, Eero-Pekka

    2013-01-01

    Uusia syöpien hoitolaitteita ja -menetelmiä kehitetään koko ajan. Suomeen saatiin vuonna 2012 Pohjoismaiden ensimmäinen CyberKnife-hoitolaite. Tästä laitteesta ei ole vielä tehty kattavaa suomenkielistä kirjallisuuskatsausta. Tämän opinnäytetyön tarkoituksena oli selvittää, millainen hoitolaite CyberKnife on ja millaisia sairauksia sillä voidaan hoitaa. Tavoitteenamme oli tuoda esille monipuolista tietoa CK-hoitolaitteesta terveydenhuoltoalan ammattilaisille ja opiskelijoille. Työ tehtiin sov...

  16. Safety and Efficacy of Ultrasound-Guided Fiducial Marker Implantation for CyberKnife Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Hyun; Hong, Seong; Sook; Kim, Jung Hoon; Park, Hyun Jeong; Chang, Yun Woo; Chang, A Ram [Soonchunhyang University Seoul Hospital, Seoul (Korea, Republic of); Kwon, Seok Beom [Hallym University College of Medicine, Chuncheon (Korea, Republic of)

    2012-06-15

    To evaluate the safety and technical success rate of an ultrasound-guided fiducial marker implantation in preparation for CyberKnife radiation therapy. We retrospectively reviewed 270 percutaneous ultrasound-guided fiducial marker implantations in 77 patients, which were performed from June 2008 through March 2011. Of 270 implantations, 104 were implanted in metastatic lymph nodes, 96 were in the liver, 39 were in the pancreas, and 31 were in the prostate. During and after the implantation, major and minor procedure-related complications were documented. We defined technical success as the implantation enabling adequate treatment planning and CT simulation. The major and minor complication rates were 1% and 21%, respectively. One patient who had an implantation in the liver suffered severe abdominal pain, biloma, and pleural effusion, which were considered as major complication. Abdominal pain was the most common complication in 11 patients (14%). Among nine patients who had markers inserted in the prostate, one had transient hematuria for less than 24 hours, and the other experienced transient voiding difficulty. Of the 270 implantations, 261 were successful (97%). The reasons for unsuccessful implantations included migration of fiducial markers (five implantations, 2%) and failure to discriminate the fiducial markers (three implantations, 1%). Among the unsuccessful implantation cases, six patients required additional procedures (8%). The symptomatic complications following ultrasound-guided percutaneous implantation of fiducial markers are relatively low. However, careful consideration of the relatively higher rate of migration and discrimination failure is needed when performing ultrasound-guided percutaneous implantations of fiducial markers.

  17. SU-F-T-619: Dose Evaluation of Specific Patient Plans Based On Monte Carlo Algorithm for a CyberKnife Stereotactic Radiosurgery System

    Energy Technology Data Exchange (ETDEWEB)

    Piao, J [PLA General Hospital, Beijing (China); PLA 302 Hospital, Beijing (China); Xu, S [PLA General Hospital, Beijing (China); Tsinghua University, Beijing (China); Wu, Z; Liu, Y [Tsinghua University, Beijing (China); Li, Y [Beihang University, Beijing (China); Qu, B [PLA General Hospital, Beijing (China); Duan, X [PLA 302 Hospital, Beijing (China)

    2016-06-15

    Purpose: This study will use Monte Carlo to simulate the Cyberknife system, and intend to develop the third-party tool to evaluate the dose verification of specific patient plans in TPS. Methods: By simulating the treatment head using the BEAMnrc and DOSXYZnrc software, the comparison between the calculated and measured data will be done to determine the beam parameters. The dose distribution calculated in the Raytracing, Monte Carlo algorithms of TPS (Multiplan Ver4.0.2) and in-house Monte Carlo simulation method for 30 patient plans, which included 10 head, lung and liver cases in each, were analyzed. The γ analysis with the combined 3mm/3% criteria would be introduced to quantitatively evaluate the difference of the accuracy between three algorithms. Results: More than 90% of the global error points were less than 2% for the comparison of the PDD and OAR curves after determining the mean energy and FWHM.The relative ideal Monte Carlo beam model had been established. Based on the quantitative evaluation of dose accuracy for three algorithms, the results of γ analysis shows that the passing rates (84.88±9.67% for head,98.83±1.05% for liver,98.26±1.87% for lung) of PTV in 30 plans between Monte Carlo simulation and TPS Monte Carlo algorithms were good. And the passing rates (95.93±3.12%,99.84±0.33% in each) of PTV in head and liver plans between Monte Carlo simulation and TPS Ray-tracing algorithms were also good. But the difference of DVHs in lung plans between Monte Carlo simulation and Ray-tracing algorithms was obvious, and the passing rate (51.263±38.964%) of γ criteria was not good. It is feasible that Monte Carlo simulation was used for verifying the dose distribution of patient plans. Conclusion: Monte Carlo simulation algorithm developed in the CyberKnife system of this study can be used as a reference tool for the third-party tool, which plays an important role in dose verification of patient plans. This work was supported in part by the grant

  18. Plan delivery quality assurance for CyberKnife: Statistical process control analysis of 350 film-based patient-specific QAs.

    Science.gov (United States)

    Bellec, J; Delaby, N; Jouyaux, F; Perdrieux, M; Bouvier, J; Sorel, S; Henry, O; Lafond, C

    2017-07-01

    Robotic radiosurgery requires plan delivery quality assurance (DQA) but there has never been a published comprehensive analysis of a patient-specific DQA process in a clinic. We proposed to evaluate 350 consecutive film-based patient-specific DQAs using statistical process control. We evaluated the performance of the process to propose achievable tolerance criteria for DQA validation and we sought to identify suboptimal DQA using control charts. DQAs were performed on a CyberKnife-M6 using Gafchromic-EBT3 films. The signal-to-dose conversion was performed using a multichannel-correction and a scanning protocol that combined measurement and calibration in a single scan. The DQA analysis comprised a gamma-index analysis at 3%/1.5mm and a separate evaluation of spatial and dosimetric accuracy of the plan delivery. Each parameter was plotted on a control chart and control limits were calculated. A capability index (Cpm) was calculated to evaluate the ability of the process to produce results within specifications. The analysis of capability showed that a gamma pass rate of 85% at 3%/1.5mm was highly achievable as acceptance criteria for DQA validation using a film-based protocol (Cpm>1.33). 3.4% of DQA were outside a control limit of 88% for gamma pass-rate. The analysis of the out-of-control DQA helped identify a dosimetric error in our institute for a specific treatment type. We have defined initial tolerance criteria for DQA validations. We have shown that the implementation of a film-based patient-specific DQA protocol with the use of control charts is an effective method to improve patient treatment safety on CyberKnife. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  19. Clinical outcome of fiducial-less CyberKnife radiosurgery for stage I non-small cell lung cancer

    International Nuclear Information System (INIS)

    Jung, In Hye; Song, Si Yeol; Cho, Byung Chul; Kwak, Jung Won; Jung, Nuri Hyun; Kim, Su Ssan; Choi, Eun Kyung; Jung, Jin Hong; Je, Hyoung Uk; Choi, Won Sik

    2015-01-01

    To evaluate the treatment results in early stage non-small cell lung cancer patients who have undergone fiducial-less CyberKnife radiosurgery (CKRS). From June 2011 to November 2013, 58 patients underwent CKRS at Asan Medical Center for stage I lung cancer. After excluding 14 patients, we retrospectively reviewed the records of the remaining 44 patients. All analyses were performed using SPSS ver. 21. The median age at diagnosis was 75 years. Most patients had inoperable primary lung cancer with a poor pulmonary function test with comorbidity or old age. The clinical stage was IA in 30 patients (68.2%), IB in 14 (31.8%). The mean tumor size was 2.6 cm (range, 1.2 to 4.8 cm), and the tumor was smaller than 2 cm in 12 patients (27.3%). The radiation dose given was 48-60 Gy in 3-4 fractions. In a median follow-up of 23.1 months, local recurrence occurred in three patients (2-year local recurrence-free survival rate, 90.4%) and distant metastasis occurred in 13 patients. All patients tolerated the radiosurgery well, only two patients developing grade 3 dyspnea. The most common complications were radiation-induced fibrosis and pneumonitis. Eight patients died due to cancer progression. The results showed that fiducial-less CKRS shows comparable local tumor control and survival rates to those of LINAC-based SABR or CKRS with a fiducial marker. Thus, fiducial-less CKRS using Xsight lung tracking system can be effectively and safely performed for patients with medically inoperable stage I non-small cell lung cancer without any risk of procedure-related complication

  20. Clinical outcome of fiducial-less CyberKnife radiosurgery for stage I non-small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Jung, In Hye; Song, Si Yeol; Cho, Byung Chul; Kwak, Jung Won; Jung, Nuri Hyun; Kim, Su Ssan; Choi, Eun Kyung [Dept. of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Jung, Jin Hong [Dept. of Radiation Oncology, Kyung Hee University Medical Center, Kyung Hee University School of Medicine, Seoul (Korea, Republic of); Je, Hyoung Uk [Dept. of Radiation Oncology, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan (Korea, Republic of); Choi, Won Sik [Dept. of Radiation Oncology, Gangneung Asan Hospital, Uiversity of Ulsan College of Medicine, Gangneung (Korea, Republic of)

    2015-06-15

    To evaluate the treatment results in early stage non-small cell lung cancer patients who have undergone fiducial-less CyberKnife radiosurgery (CKRS). From June 2011 to November 2013, 58 patients underwent CKRS at Asan Medical Center for stage I lung cancer. After excluding 14 patients, we retrospectively reviewed the records of the remaining 44 patients. All analyses were performed using SPSS ver. 21. The median age at diagnosis was 75 years. Most patients had inoperable primary lung cancer with a poor pulmonary function test with comorbidity or old age. The clinical stage was IA in 30 patients (68.2%), IB in 14 (31.8%). The mean tumor size was 2.6 cm (range, 1.2 to 4.8 cm), and the tumor was smaller than 2 cm in 12 patients (27.3%). The radiation dose given was 48-60 Gy in 3-4 fractions. In a median follow-up of 23.1 months, local recurrence occurred in three patients (2-year local recurrence-free survival rate, 90.4%) and distant metastasis occurred in 13 patients. All patients tolerated the radiosurgery well, only two patients developing grade 3 dyspnea. The most common complications were radiation-induced fibrosis and pneumonitis. Eight patients died due to cancer progression. The results showed that fiducial-less CKRS shows comparable local tumor control and survival rates to those of LINAC-based SABR or CKRS with a fiducial marker. Thus, fiducial-less CKRS using Xsight lung tracking system can be effectively and safely performed for patients with medically inoperable stage I non-small cell lung cancer without any risk of procedure-related complication.

  1. SU-F-SPS-02: Accuracy of the Small Field Dosimetry Using the Monte Carlo and Sequential Dose Calculation Algorithms of Multiplan Treatment Planning System Within and Beyond Heterogeneous Media for Cyberknife M6 Unit

    Energy Technology Data Exchange (ETDEWEB)

    Serin, E.; Codel, G.; Mabhouti, H.; Cebe, M.; Sanli, E.; Pacaci, P.; Kucuk, N.; Kucukmorkoc, E.; Doyuran, M.; Canoglu, D.; Altinok, A.; Acar, H.; Caglar Ozkok, H. [Medipol University, Istanbul, Istanbul (Turkey)

    2016-06-15

    Purpose: In small field geometries, the electronic equilibrium can be lost, making it challenging for the dose-calculation algorithm to accurately predict the dose, especially in the presence of tissue heterogeneities. In this study, dosimetric accuracy of Monte Carlo (MC) advanced dose calculation and sequential algorithms of Multiplan treatment planning system were investigated for small radiation fields incident on homogeneous and heterogeneous geometries. Methods: Small open fields of fixed cones of Cyberknife M6 unit 100 to 500 mm2 were used for this study. The fields were incident on in house phantom containing lung, air, and bone inhomogeneities and also homogeneous phantom. Using the same film batch, the net OD to dose calibration curve was obtained using CK with the 60 mm fixed cone by delivering 0- 800 cGy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. The dosimetric accuracy of MC and sequential algorithms in the presence of the inhomogeneities was compared against EBT3 film dosimetry Results: Open field tests in a homogeneous phantom showed good agreement between two algorithms and film measurement For MC algorithm, the minimum gamma analysis passing rates between measured and calculated dose distributions were 99.7% and 98.3% for homogeneous and inhomogeneous fields in the case of lung and bone respectively. For sequential algorithm, the minimum gamma analysis passing rates were 98.9% and 92.5% for for homogeneous and inhomogeneous fields respectively for used all cone sizes. In the case of the air heterogeneity, the differences were larger for both calculation algorithms. Overall, when compared to measurement, the MC had better agreement than sequential algorithm. Conclusion: The Monte Carlo calculation algorithm in the Multiplan treatment planning system is an improvement over the existing sequential algorithm. Dose discrepancies were observed for in the presence of air inhomogeneities.

  2. SU-F-SPS-02: Accuracy of the Small Field Dosimetry Using the Monte Carlo and Sequential Dose Calculation Algorithms of Multiplan Treatment Planning System Within and Beyond Heterogeneous Media for Cyberknife M6 Unit

    International Nuclear Information System (INIS)

    Serin, E.; Codel, G.; Mabhouti, H.; Cebe, M.; Sanli, E.; Pacaci, P.; Kucuk, N.; Kucukmorkoc, E.; Doyuran, M.; Canoglu, D.; Altinok, A.; Acar, H.; Caglar Ozkok, H.

    2016-01-01

    Purpose: In small field geometries, the electronic equilibrium can be lost, making it challenging for the dose-calculation algorithm to accurately predict the dose, especially in the presence of tissue heterogeneities. In this study, dosimetric accuracy of Monte Carlo (MC) advanced dose calculation and sequential algorithms of Multiplan treatment planning system were investigated for small radiation fields incident on homogeneous and heterogeneous geometries. Methods: Small open fields of fixed cones of Cyberknife M6 unit 100 to 500 mm2 were used for this study. The fields were incident on in house phantom containing lung, air, and bone inhomogeneities and also homogeneous phantom. Using the same film batch, the net OD to dose calibration curve was obtained using CK with the 60 mm fixed cone by delivering 0- 800 cGy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. The dosimetric accuracy of MC and sequential algorithms in the presence of the inhomogeneities was compared against EBT3 film dosimetry Results: Open field tests in a homogeneous phantom showed good agreement between two algorithms and film measurement For MC algorithm, the minimum gamma analysis passing rates between measured and calculated dose distributions were 99.7% and 98.3% for homogeneous and inhomogeneous fields in the case of lung and bone respectively. For sequential algorithm, the minimum gamma analysis passing rates were 98.9% and 92.5% for for homogeneous and inhomogeneous fields respectively for used all cone sizes. In the case of the air heterogeneity, the differences were larger for both calculation algorithms. Overall, when compared to measurement, the MC had better agreement than sequential algorithm. Conclusion: The Monte Carlo calculation algorithm in the Multiplan treatment planning system is an improvement over the existing sequential algorithm. Dose discrepancies were observed for in the presence of air inhomogeneities.

  3. A treatment planning comparison between a novel rotating gamma system and robotic linear accelerator based intracranial stereotactic radiosurgery/radiotherapy

    Science.gov (United States)

    Fareed, Muhammad M.; Eldib, Ahmed; Weiss, Stephanie E.; Hayes, Shelly B.; Li, Jinsheng; C-M Ma, Charlie

    2018-02-01

    To compare the dosimetric parameters of a novel rotating gamma ray system (RGS) with well-established CyberKnife system (CK) for treating malignant brain lesions. RGS has a treatment head of 16 cobalt-60 sources focused to the isocenter, which can rotate 360° on the ring gantry and swing 35° in the superior direction. We compared several dosimetric parameters in 10 patients undergoing brain stereotactic radiosurgery including plan normalization, number of beams and nodes for CK and shots for RGS, collimators used, estimated treatment time, D 2 cm and conformity index (CI) among two modalities. The median plan normalization for RGS was 56.7% versus 68.5% (p  =  0.002) for CK plans. The median number of shots from RGS was 7.5 whereas the median number of beams and nodes for CK was 79.5 and 46. The median collimator’s diameter used was 3.5 mm for RGS as compared to 5 mm for CK (p  =  0.26). Mean D 2 cm was 5.57 Gy for CyberKnife whereas it was 3.11 Gy for RGS (p  =  0.99). For RGS plans, the median CI was 1.4 compared to 1.3 for the CK treatment plans (p  =  0.98). The average minimum and maximum doses to optic chiasm were 21 and 93 cGy for RGS as compared to 32 and 209 cGy for CK whereas these were 0.5 and 364 cGy by RGS and 18 and 399 cGy by CK to brainstem. The mean V12 Gy for brain predicting for radionecrosis with RGS was 3.75 cm3 as compared to 4.09 cm3 with the CK (p  =  0.41). The dosimetric parameters of a novel RGS with a ring type gantry are comparable with CyberKnife, allowing its use for intracranial lesions and is worth exploring in a clinical setting.

  4. SU-E-T-225: Correction Matrix for PinPoint Ionization Chamber for Dosimetric Measurements in the Newly Released Incise™ Multileaf Collimator Shaped Small Field for CyberKnife M6™ Machine

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Y; Li, T; Heron, D; Huq, M [University of Pittsburgh Cancer Institute and UPMC CancerCenter, Pittsburgh, PA (United States)

    2015-06-15

    Purpose: For small field dosimetry, such as measurements of output factors for cones or MLC-shaped irregular small fields, ion chambers often Result in an underestimation of the dose, due to both the volume averaging effect and the lack of lateral charged particle equilibrium. This work presents a mathematical model for correction matrix for a PTW PinPoint ionization chamber for dosimetric measurements made in the newly released Incise™ Multileaf collimator fields of the CyberKnife M6™ machine. Methods: A correction matrix for a PTW 0.015cc PinPoint ionization chamber was developed by modeling its 3D dose response in twelve cone-shaped circular fields created using the 5mm, 7.5mm, 10mm, 12.5mm, 15mm, 20mm, 25mm, 30mm, 35mm, 40mm, 50mm, 60mm cones in a CyberKnife M6™ machine. For each field size, hundreds of readings were recorded for every 2mm chamber shift in the horizontal plane. The contribution of each dose pixel to a measurement point depended on the radial distance and the angle to the chamber axis. These readings were then compared with the theoretical dose as obtained with Monte Carlo calculation. A penalized least-square optimization algorithm was developed to generate the correction matrix. After the parameter fitting, the mathematical model was validated for MLC-shaped irregular fields. Results: The optimization algorithm used for parameter fitting was stable and the resulted response factors were smooth in spatial domain. After correction with the mathematical model, the chamber reading matched with the calculation for all the tested fields to within 2%. Conclusion: A novel mathematical model has been developed for PinPoint chamber for dosimetric measurements in small MLC-shaped irregular fields. The correction matrix is dependent on detector, treatment unit and the geometry of setup. The model can be applied to non-standard composite fields and provides an access to IMRT point dose validation.

  5. SU-E-T-225: Correction Matrix for PinPoint Ionization Chamber for Dosimetric Measurements in the Newly Released Incise™ Multileaf Collimator Shaped Small Field for CyberKnife M6™ Machine

    International Nuclear Information System (INIS)

    Zhang, Y; Li, T; Heron, D; Huq, M

    2015-01-01

    Purpose: For small field dosimetry, such as measurements of output factors for cones or MLC-shaped irregular small fields, ion chambers often Result in an underestimation of the dose, due to both the volume averaging effect and the lack of lateral charged particle equilibrium. This work presents a mathematical model for correction matrix for a PTW PinPoint ionization chamber for dosimetric measurements made in the newly released Incise™ Multileaf collimator fields of the CyberKnife M6™ machine. Methods: A correction matrix for a PTW 0.015cc PinPoint ionization chamber was developed by modeling its 3D dose response in twelve cone-shaped circular fields created using the 5mm, 7.5mm, 10mm, 12.5mm, 15mm, 20mm, 25mm, 30mm, 35mm, 40mm, 50mm, 60mm cones in a CyberKnife M6™ machine. For each field size, hundreds of readings were recorded for every 2mm chamber shift in the horizontal plane. The contribution of each dose pixel to a measurement point depended on the radial distance and the angle to the chamber axis. These readings were then compared with the theoretical dose as obtained with Monte Carlo calculation. A penalized least-square optimization algorithm was developed to generate the correction matrix. After the parameter fitting, the mathematical model was validated for MLC-shaped irregular fields. Results: The optimization algorithm used for parameter fitting was stable and the resulted response factors were smooth in spatial domain. After correction with the mathematical model, the chamber reading matched with the calculation for all the tested fields to within 2%. Conclusion: A novel mathematical model has been developed for PinPoint chamber for dosimetric measurements in small MLC-shaped irregular fields. The correction matrix is dependent on detector, treatment unit and the geometry of setup. The model can be applied to non-standard composite fields and provides an access to IMRT point dose validation

  6. SU-F-T-552: A One-Year Evaluation of the QABeamChecker+ for Use with the CyberKnife System

    Energy Technology Data Exchange (ETDEWEB)

    Gersh, J [Gibbs Cancer Center & Research Institute - Pelham, Greer SC (United States); Spectrum Medical Physics, LLC, Greenville, SC (United States)

    2016-06-15

    Purpose: By attaching an adapter plate with fiducial markers to the QA BeamChecker+ (Standard Imaging, Inc., Middleton, WI), the output of the CyberKnife can be accurately, efficiently, and consistently evaluated. The adapter plate, known as the Cutting Board, allows for automated alignment of the QABC+ using the CK’s stereoscopic kV image-based treatment localization system (TLS). Described herein is an evaluation of the system following a year of clinical utilization. Methods: Based on a CT scan of the QABC+ and CB, a treatment plan is generated which delivers a beam to each of the 5 plane-parallel ionization chambers. Following absolute calibration of the CK, the QA plan is delivered, and baseline measurements are acquired (and automatically corrected for temperature and pressure). This test was performed at the beginning of each treatment day for a year. A calibration evaluation (using a water-equivalent slab and short thimble chamber) is performed every four weeks, or whenever the QABC+ detects a deviation of more than 1.0%. Results: During baseline evaluation, repeat measurements (n=10) were performed, with an average output of 0.25% with an SD of 0.11%. As a test of the reposition of the QABC+ and CB, ten additional measurements were performed where between each acquisition, the entire system was removed and re-positioned using the TLS. The average output deviation was 0.30% with a SD of 0.13%. During the course of the year, 187 QABC+ measurements and 13 slab-based measurements were performed. The output measurements of the QABC+ correlated well with slab-based measurements (R2=0.909). Conclusion: By using the QABC+ and CB, daily output was evaluated accurately, efficiently, and consistently. From setup to break-down (including analysis), this test required 5 minutes instead of approximately 15 using traditional techniques (collimator-mounted ionization chambers). Additionally, by automatically saving resultant output deviation to a database, trend

  7. Which level of treatment quality can be obtained by a robotized irradiation system conducted by image in radiotherapy (CyberKnifeTM)

    International Nuclear Information System (INIS)

    Al Khawaja, S.

    2011-01-01

    The CyberKnife TM consists of a 6 MV LINAC mounted on a robotic arm, with six degree of freedom and is coupled to an image guiding system, allowing us to guide the irradiation beams toward the target. The aim is to improve the treatment accuracy and to reduce the irradiation of critical surrounding organs. The treatment is realized by the isotropic convergence of hundreds of orientations for creating up to 1200 mini-beams, which are orientated to the target with sub-millimetric accuracy. This group is completed by a treatment couch, which is also mounted on a robotized arm, that offers 6 additional degrees of freedom, allowing an additional improvement of accuracy, and eliminates the possible limitations. Using its subsystem Synchrony TM , the CyberKnife TM is capable of treating the abdo-thoracic tumors, which move with respiration, by moving dynamically the LINAC to compensate the respiratory motion of the tumors. The high dose level, which is used in this kind of hypo-fractionated treatment, makes the smallest error unacceptable, and needs a very high geometric accuracy with keeping a maximal dosimetric accuracy. Our work is dedicated to evaluate the quality of treatment, in the terms of dosimetric and geometric accuracies. For the different modes of tracking, which are available in the system in static mode, and dynamic mode with respiratory motion tracking. By using different kinds of detectors (ionization chambers, radiochromic films) and three different platforms, which allow simulating simple respiratory motion, real respiratory motion coming from real treated patients, and finally complex motion with hysteresis. The results show clearly the high dosimetric accuracy of the system; this is accompanied by a sub-millimetric geometric accuracy. This geometric accuracy degrades slightly, when treating in dynamic mode with respiratory tracking by Synchrony TM , and especially when the respiratory cycles show a high variation in amplitudes, while the dosimetric

  8. A New Cancer Radiotherapy System Using Multi Robotic Manipulators

    International Nuclear Information System (INIS)

    Kim, Seung Ho; Lee, Nam Ho; Lee, Byung Chul; Jeung, Kyung Min; Lee, Seong Uk; Bae, Yeong Geol; Na, Hyun Seok

    2013-01-01

    The CyberKnife system is state-of-the-art cancer treatment equipment that combines an image tracking technique, artificial intelligence software, robot technology, accelerator technology, and treatment simulation technology. The current CyberKnife System has significant shortcomings. The biggest problem is that it takes a longer time to treat a tumor. A long treatment time gives stress to patients. Furthermore it makes the patients uncomfortable with radiation and thus it is difficult to measure the exact radiation dose rate to the tumor in the processing. Linear accelerators for radiation treatment are dependent on imports, and demand high maintenance cost. This also makes the treatment cost higher and prevents the popularization of radiation. To solve the disadvantages of the existing CyberKnife, a radiation treatment robot system applied to several articulated robots is suggested. Essential element techniques for new radiotherapy robot system are investigated and some problems of similar existing systems are analyzed. This paper presents a general configuration of a new radiation robot treatment system including with a quantitative goal of the requirement techniques. This paper described a new radiotherapy robot system to track the tumor using multiple articulated robots in real time. The existing CyberKnife system using a single robot arm has disadvantages of a long radiotherapy time, high medical fee, and inaccurate measurement of the radiotherapy dose. So a new radiotherapy robot system for tumors has been proposed to solve the above problems of conventional CyberKnife systems. Necessary technologies to configure new the radiotherapy robot system have been identified. Quantitative targets of each technology have been established. Multiple robot arms are adopted to decrease the radiotherapy time. The results of this research are provided as a requisite technology for a domestic radiotherapy system and are expected to be the foundation of new technology. The

  9. A New Cancer Radiotherapy System Using Multi Robotic Manipulators

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Ho; Lee, Nam Ho; Lee, Byung Chul; Jeung, Kyung Min; Lee, Seong Uk; Bae, Yeong Geol; Na, Hyun Seok [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    The CyberKnife system is state-of-the-art cancer treatment equipment that combines an image tracking technique, artificial intelligence software, robot technology, accelerator technology, and treatment simulation technology. The current CyberKnife System has significant shortcomings. The biggest problem is that it takes a longer time to treat a tumor. A long treatment time gives stress to patients. Furthermore it makes the patients uncomfortable with radiation and thus it is difficult to measure the exact radiation dose rate to the tumor in the processing. Linear accelerators for radiation treatment are dependent on imports, and demand high maintenance cost. This also makes the treatment cost higher and prevents the popularization of radiation. To solve the disadvantages of the existing CyberKnife, a radiation treatment robot system applied to several articulated robots is suggested. Essential element techniques for new radiotherapy robot system are investigated and some problems of similar existing systems are analyzed. This paper presents a general configuration of a new radiation robot treatment system including with a quantitative goal of the requirement techniques. This paper described a new radiotherapy robot system to track the tumor using multiple articulated robots in real time. The existing CyberKnife system using a single robot arm has disadvantages of a long radiotherapy time, high medical fee, and inaccurate measurement of the radiotherapy dose. So a new radiotherapy robot system for tumors has been proposed to solve the above problems of conventional CyberKnife systems. Necessary technologies to configure new the radiotherapy robot system have been identified. Quantitative targets of each technology have been established. Multiple robot arms are adopted to decrease the radiotherapy time. The results of this research are provided as a requisite technology for a domestic radiotherapy system and are expected to be the foundation of new technology. The

  10. Clinical Accuracy of the Respiratory Tumor Tracking System of the CyberKnife: Assessment by Analysis of Log Files

    International Nuclear Information System (INIS)

    Hoogeman, Mischa; Prevost, Jean-Briac; Nuyttens, Joost; Poell, Johan; Levendag, Peter; Heijmen, Ben

    2009-01-01

    Purpose: To quantify the clinical accuracy of the respiratory motion tracking system of the CyberKnife treatment device. Methods and Materials: Data in log files of 44 lung cancer patients treated with tumor tracking were analyzed. Errors in the correlation model, which relates the internal target motion with the external breathing motion, were quantified. The correlation model error was compared with the geometric error obtained when no respiratory tracking was used. Errors in the prediction method were calculated by subtracting the predicted position from the actual measured position after 192.5 ms (the time lag to prediction in our current system). The prediction error was also measured for a time lag of 115 ms and a new prediction method. Results: The mean correlation model errors were less than 0.3 mm. Standard deviations describing intrafraction variations around the whole-fraction mean error were 0.2 to 1.9 mm for cranio-caudal, 0.1 to 1.9 mm for left-right, and 0.2 to 2.5 mm for anterior-posterior directions. Without the use of respiratory tracking, these variations would have been 0.2 to 8.1 mm, 0.2 to 5.5 mm, and 0.2 to 4.4 mm. The overall mean prediction error was small (0.0 ± 0.0 mm) for all directions. The intrafraction standard deviation ranged from 0.0 to 2.9 mm for a time delay of 192.5 ms but was halved by using the new prediction method. Conclusions: Analyses of the log files of real clinical cases have shown that the geometric error caused by respiratory motion is substantially reduced by the application of respiratory motion tracking.

  11. Reported case of a grade 3 toxicity after treatment of an hepatic metastasis by CyberKnife{sup R}; Cas rapporte d'une toxicite de grade 3 apres traitement d'une metastase hepatique par CyberKnife{sup R}

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, A.S.; Taste-George, H.; Marchesi, V.; Buccheit, I.; Beckendorf, V.; Peiffert, D. [Centre Alexis-Vautrin, Vandceuvre -les-Nancy (France)

    2011-10-15

    The authors briefly describe the treatment plan dosimetry for a patient irradiated several times with CyberKnife in the liver and suffering from a grade 3 toxicity of gastric-antrum-ulcer type. They conclude that dose constraints for organs at risk must be scrupulously respected within the frame of hypo-fractionated treatments because side effects can be severe and difficult to treat. Short communication

  12. Quality assurance for an image-guided frameless radiosurgery system using radiochromic film

    International Nuclear Information System (INIS)

    Shiomi, Hiroya; Inoue, Takehiro; Nakamura, Satoaki; Inoue, Toshihiko

    2000-01-01

    The CyberKnife, a new type of machine for stereotactic irradiation, is composed of a combination of a robot (manipulator) and a linear accelerator. We measured the total pointing error of the therapy beam, aiming at improvement in the accuracy of the CyberKnife. The CyberKnife keeps a number of coordinate systems such as the patient's coordinates, robotic coordinates, and IPS (image processing system) coordinates. Precise irradiation is possible if these coordinate systems are matched accurately. We always calculate the overall irradiation error using GAF MD-55 radiochromic film before irradiation treatment of the patient, and we have attempted to improve the accuracy of irradiation with the CyberKnife by feeding back the errors. The median of the error immediately after introducing the CyberKnife was 1.2 mm, and as a result of correction, we succeeded in reducing the error to 0.7 mm (median). Total pointing error after correction was significantly lower than that before correction (p=0.0023). This approach allowed us to reduce errors and establish a method for providing patients with highly accurate stereotactic irradiation. We believe these results endorse the validity of the method presented in this paper. (author)

  13. SU-G-JeP1-10: Feasibility of CyberKnife Tracking Using the Previously-Implanted Permanent Brachytherapy Seed Cloud

    International Nuclear Information System (INIS)

    Cheung, J; Cunha, J; Sudhyadhom, A; McGuinness, C; Roach, M; Descovich, M

    2016-01-01

    Purpose: Robotic radiosurgery is a salvage treatment option for patients with recurrent prostate cancer. We explored the feasibility of tracking the bolus of permanent prostate implants (PPI) using image recognition software optimized to track spinal anatomy. Methods: Forty-five inert iodine seeds were implanted into a gelatin-based prostate phantom. Four superficial gold seeds were inserted to provide ground-truth alignment. A CT scan of the phantom (120 kVp, 1 mm slice thickness) was acquired and a single-energy iterative metal artifact reduction (MAR) algorithm was used to enhance the quality of the DRR used for tracking. CyberKnife treatment plans were generated from the MAR CT and regular CT (no-MAR) using spine tracking. The spine-tracking grid was centered on the bolus of seeds and resized to encompass the full seed cloud. A third plan was created from the regular CT scan, using fiducial tracking based on the 4 superficial gold seeds with identical align-center coordinates. The phantom was initially aligned using the fiducial-tracking plan. Then the MAR and no-MAR spine-tracking plans were loaded without moving the phantom. Differences in couch correction parameters were recorded in the case of perfect alignment and after the application of known rotations and translations (roll/pitch of 2 degrees; translations XYZ of 2 cm). Results: The spine tracking software was able to lock on to the bolus of seeds and provide couch corrections both in the MAR and no-MAR plans. In all cases, differences in the couch correction parameters from fiducial alignment were <0.5 mm in translations and <1 degree in rotations. Conclusion: We were able to successfully track the bolus of seeds with the spine-tracking grid in phantom experiments. For clinical applications, further investigation and developments to adapt the spine-tracking algorithm to optimize for PPI seed cloud tracking is needed to provide reliable tracking in patients. One of the authors (MD) has received research

  14. SU-G-JeP1-10: Feasibility of CyberKnife Tracking Using the Previously-Implanted Permanent Brachytherapy Seed Cloud

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, J; Cunha, J; Sudhyadhom, A; McGuinness, C; Roach, M; Descovich, M [University of California San Francisco, San Francisco, CA (United States)

    2016-06-15

    Purpose: Robotic radiosurgery is a salvage treatment option for patients with recurrent prostate cancer. We explored the feasibility of tracking the bolus of permanent prostate implants (PPI) using image recognition software optimized to track spinal anatomy. Methods: Forty-five inert iodine seeds were implanted into a gelatin-based prostate phantom. Four superficial gold seeds were inserted to provide ground-truth alignment. A CT scan of the phantom (120 kVp, 1 mm slice thickness) was acquired and a single-energy iterative metal artifact reduction (MAR) algorithm was used to enhance the quality of the DRR used for tracking. CyberKnife treatment plans were generated from the MAR CT and regular CT (no-MAR) using spine tracking. The spine-tracking grid was centered on the bolus of seeds and resized to encompass the full seed cloud. A third plan was created from the regular CT scan, using fiducial tracking based on the 4 superficial gold seeds with identical align-center coordinates. The phantom was initially aligned using the fiducial-tracking plan. Then the MAR and no-MAR spine-tracking plans were loaded without moving the phantom. Differences in couch correction parameters were recorded in the case of perfect alignment and after the application of known rotations and translations (roll/pitch of 2 degrees; translations XYZ of 2 cm). Results: The spine tracking software was able to lock on to the bolus of seeds and provide couch corrections both in the MAR and no-MAR plans. In all cases, differences in the couch correction parameters from fiducial alignment were <0.5 mm in translations and <1 degree in rotations. Conclusion: We were able to successfully track the bolus of seeds with the spine-tracking grid in phantom experiments. For clinical applications, further investigation and developments to adapt the spine-tracking algorithm to optimize for PPI seed cloud tracking is needed to provide reliable tracking in patients. One of the authors (MD) has received research

  15. CyberKnife robotic image-guided stereotactic radiotherapy for oligometastic cancer. A prospective evaluation of 95 patients/118 lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jereczek-Fossa, B.A.; Bossi-Zanetti, I.; Mauro, R. [European Institute of Oncology, Milan (Italy). Dept. of Radiotherapy; Milan Univ. (Italy); Beltramo, G.; Bianchi, L.C. [CyberKnife Center CDI, Milan (Italy); Fariselli, L. [Carlo Besta Neurological Institute Foundation, Milan (Italy). Radiotherapy Unit; Fodor, C. [European Institute of Oncology, Milan (Italy). Dept. of Radiotherapy; Fossati, P.; Orecchia, R. [European Institute of Oncology, Milan (Italy). Dept. of Radiotherapy; National Center for Oncological Hadrontherapy (CNAO) Foundation, Pavia, Milan (Italy); Milan Univ. (Italy); Baroni, G. [National Center for Oncological Hadrontherapy (CNAO) Foundation, Pavia, Milan (Italy); Politecnico di Milano (Italy). Dept. of Bioengineering

    2013-06-15

    Purpose: To evaluate the outcome of robotic CyberKnife (Accuray Inc. Sunnyvale, USA)-based stereotactic radiotherapy (CBK-SRT) for oligometastic cancer patients. Patients and methods: Between May 2007 and December 2009, 95 patients with a total of 118 lesions underwent CBK-SRT (median dose 24 Gy in 3 fractions). Inclusion criteria: adult patients with limited volume cancer; suitability for SRT but not for other local therapies. Primary diagnoses included breast, lung, head and neck, gastrointestinal and other malignancies. Prostate cancer patients were excluded. Concomitant systemic therapy was given in 40 % of cases and median follow-up was 12 months. Toxicity and tumor response were evaluated using the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer (RTOG/EORTC) Scale and Response Evaluation Criteria in Solid Tumors RECIST. Results: Toxicity was rare and observed mainly in patients with comorbidities or uncontrolled cancer. Out of 87 evaluable lesions, complete radiological response, partial response, stabilization and progressive disease were observed in 15 (17 %), 25 (29 %), 34 (39 %) and 13 (15 %) lesions, respectively. Upon restricting the analysis to lesions treated with CBK-SRT alone (no concomitant therapy), response- and local control (LC) rates remained similar. Actuarial 3-year in-field progression-free survival- (i.e. LC), progression-free survival- (PFS) and overall-survival (OS) rates were 67.6, 18.4, and 31.2 %, respectively. LC was reduced in cases of early recurrence. OS- and cause-specific survival (CSS) rates were significantly lower in patients treated for visceral lesions. Failures were predominantly out-field. Conclusion: CBK-SRT is a feasible therapeutic approach for oligometastastic cancer patients that provides long-term in-field tumor control with a low toxicity profile. Further investigations should focus on dose escalation and optimization of the combination with systemic therapies. (orig.)

  16. Frameless Stereotactic Radiosurgery for Treatment of Multiple Sclerosis-Related Trigeminal Neuralgia.

    Science.gov (United States)

    Conti, Alfredo; Pontoriero, Antonio; Iatì, Giuseppe; Esposito, Felice; Siniscalchi, Enrico Nastro; Crimi, Salvatore; Vinci, Sergio; Brogna, Anna; De Ponte, Francesco; Germanò, Antonino; Pergolizzi, Stefano; Tomasello, Francesco

    2017-07-01

    Trigeminal neuralgia (TN) affects 7% of patients with multiple sclerosis (MS). In such patients, TN is difficult to manage either pharmacologically and surgically. Radiosurgical rhizotomy is an effective treatment option. The nonisocentric geometry of radiation beams of CyberKnife introduces new concepts in the treatment of TN. Its efficacy for MS-related TN has not yet been demonstrated. Twenty-seven patients with refractory TN and MS were treated. A nonisocentric beams distribution was chosen; the maximal target dose was 72.5 Gy. The maximal dose to the brainstem was <12 Gy. Effects on pain, medications, sensory disturbance, rate, and time of pain recurrence were analyzed. Median follow-up was 37 (18-72) months. Barrow Neurological Institute pain scale score I-III was achieved in 23/27 patients (85%) within 45 days. Prescription isodose line (80%) accounting for a dose of 58 Gy incorporated an average of 4.85 mm (4-6 mm) of the nerve and mean nerve volume of 26.4 mm 3 (range 20-38 mm 3 ). Seven out of 27 patients (26%) had mild, not bothersome, facial numbness (Barrow Neurological Institute numbness score II). The rate of pain control decreased progressively after the first year, and only 44% of patients retained pain control 4 years later. Frameless radiosurgery can be effectively used to perform retrogasserian rhizotomy. Pain relief was satisfactory and, with our dose/volume constraints, no sensory complications were recorded. Nonetheless, long-term pain control was possible in less than half of the patients. This is a limitation that CyberKnife radiosurgery shares with other techniques in MS patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. TU-F-CAMPUS-T-03: A Novel Iris Quality Assurance Phantom for the CyberKnife Radiosurgery System

    Energy Technology Data Exchange (ETDEWEB)

    Descovich, M; Pinnaduwage, D; Sudhyadhom, A [University of California San Francisco, San Francisco, CA (United States); Nelson, B [Logos Systems Int’l, Scotts Valley, CA (United States)

    2015-06-15

    Purpose: A novel CCD camera and conical scintillator based phantom that is capable of measuring the targeting and field size accuracy of a robotic radiosurgery system has been developed. This work investigates its application in measuring the field sizes and beam divergence of the CyberKnife variable aperture collimator (Iris). Methods: The phantom was placed on the treatment couch and the robot position was adjusted to obtain an anterior -posterior beam perpendicular to the cone’s central axis. The FWHM of the 12 Iris apertures (5, 7.5, 10, 12.5, 15, 20, 25, 30, 35, 40, 50, and 60 mm) were measured from the beam flux map on the conical scintillator surface as seen by the CCD camera. For each measurement 30 MU were delivered to the phantom at a dose rate of 1000 MU/min. The measurements were repeated at 4 SAD distances between 75 and 85 cm. These readings were used to project the aperture size as if the flux map on the scintillator were located 80 cm from the source (SSD). These projected FWHM beam diameters were then compared to the commissioning data. Results: A series of 12 beam divergence equations were obtained from the 4 sets of data using linear trend lines on Excel scatter plots. These equations were then used to project the FWHM measurements at 80 cm SSD. The average aperture accuracy for beams from 5 through 40 mm was 0.08 mm. The accuracy for the 50 and 60 mm beams were 0.33 and 0.58 mm when compared to film commissioning data. Conclusion: The experimental results for 10 apertures agree with the stated Iris accuracy of ±0.2 mm at 80 cm SAD. The results for the 50 and 60 mm aperture were repeatable and can serve as a reliable trend indicator of any deviations away from the commissioning values. Brett Nelson is President/CTO of Logos Systems.

  18. A phase I/II study on stereotactic body radiotherapy with real-time tumor tracking using CyberKnife based on the Monte Carlo algorithm for lung tumors.

    Science.gov (United States)

    Iwata, Hiromitsu; Ishikura, Satoshi; Murai, Taro; Iwabuchi, Michio; Inoue, Mitsuhiro; Tatewaki, Koshi; Ohta, Seiji; Yokota, Naoki; Shibamoto, Yuta

    2017-08-01

    In this phase I/II study, we assessed the safety and initial efficacy of stereotactic body radiotherapy (SBRT) for lung tumors with real-time tumor tracking using CyberKnife based on the Monte Carlo algorithm. Study subjects had histologically confirmed primary non-small-cell lung cancer staged as T1a-T2aN0M0 and pulmonary oligometastasis. The primary endpoint was the incidence of Grade ≥3 radiation pneumonitis (RP) within 180 days of the start of SBRT. The secondary endpoint was local control and overall survival rates. Five patients were initially enrolled at level 1 [50 Gy/4 fractions (Fr)]; during the observation period, level 0 (45 Gy/4 Fr) was opened. The dose was escalated to the next level when grade ≥3 RP was observed in 0 out of 5 or 1 out of 10 patients. Virtual quality assurance planning was performed for 60 Gy/4 Fr; however, dose constraints for the organs at risk did not appear to be within acceptable ranges. Therefore, level 2 (55 Gy/4 Fr) was regarded as the upper limit. After the recommended dose (RD) was established, 15 additional patients were enrolled at the RD. The prescribed dose was normalized at the 95% volume border of the planning target volume based on the Monte Carlo algorithm. Between September 2011 and September 2015, 40 patients (primary 30; metastasis 10) were enrolled. Five patients were enrolled at level 0, 15 at level 1, and 20 at level 2. Only one grade 3 RP was observed at level 1. Two-year local control and overall survival rates were 98 and 81%, respectively. The RD was 55 Gy/4 Fr. SBRT with real-time tumor tracking using CyberKnife based on the Monte Carlo algorithm was tolerated well and appeared to be effective for solitary lung tumors.

  19. Frequency, outcome and prognostic factors of carotid blowout syndrome after hypofractionated re-irradiation of head and neck cancer using CyberKnife: A multi-institutional study

    International Nuclear Information System (INIS)

    Yamazaki, Hideya; Ogita, Mikio; Kodani, Naohiro; Nakamura, Satoakai; Inoue, Hiroshi; Himei, Kengo; Kotsuma, Tadayuki; Yoshida, Ken; Yoshioka, Yasuo; Yamashita, Koichi; Udono, Hiroki

    2013-01-01

    Purpose: Re-irradiation has attracted attention as a potential therapy for recurrent head and neck tumors. However, carotid blowout syndrome (CBS) has become a serious complication of re-irradiation because of the associated life-threatening toxicity. Determining of the characteristics of CBS is important. We conducted a multi-institutional study. Methods and patients: Head and neck carcinoma patients (n = 381) were treated with 484 re-irradiation sessions at 7 Japanese CyberKnife institutions between 2000 and 2010. Results: Of these, 32 (8.4%) developed CBS, which proved fatal that median survival time after CBS onset was 0.1 month, and the 1-year survival rate was 37.5%. The median duration between re-irradiation and CBS onset was 5 months (range, 0–69 months). Elder age, skin invasion, and necrosis/infection were identified as statistically significant risk factors after CBS by univariate analysis. The presence of skin invasion at the time of treatment found only in postoperative case, is identified as only statistically significant prognostic factor after CBS in multivariate analysis. The 1-year survival rate for the group without skin invasion was 42%, whereas no patient with skin invasion survived more than 4 months (0% at 1 year, p = 0.0049). Conclusions: Careful attention should be paid to the occurrence of CBS if the tumor is located adjacent to the carotid artery. The presence of skin invasion at CBS onset is ominous sign of lethal consequences

  20. Robotic radiosurgery. Treating tumors that move with respiration

    International Nuclear Information System (INIS)

    Urschel, Harold C. Jr.; Kresl, John J.; Luketich, James D.; Papiez, Lech; Timmerman, Robert D.; Schulz, Raymond A.

    2007-01-01

    Addresses in detail all aspects of the use of robotic radiosurgery to treat tumors of the lung, liver, and pancreas Includes full consideration of tumor tracking techniques, dosimetry, radiobiology, and fiducial placement strategies Written by leading experts Includes many high quality illustrations Stereotactic radiosurgery continues to evolve in ways that allow this powerful technology to reach and treat more tumors in more patients. This volume in the Robotic Radiosurgery series is devoted to theory and practice in the emerging field of stereotactic radiosurgery (also called stereotactic body radiation therapy) for extracranial tumors, particularly those that move as patients breathe. The book is divided into six sections. The first three sections address tumor motion due to respiration and tumor tracking techniques; dosimetry, radiobiology, and imaging; and fiducial placement systems. The fourth and fifth sections then discuss in depth the use of robotic radiosurgery to treat lung and abdominal tumors, respectively, and a final section explains emerging concepts and techniques. Within this framework, detailed information is provided on the technology and methodology for delivery of high doses of radiation to moving targets, radiobiological and radiological principles, and the challenges faced by clinicians performing extracranial stereotactic radiosurgery. Furthermore, there are thorough reviews of the general clinical literature on stereotactic radiation treatment of tumors of the lungs, liver, and pancreas, and the latest clinical data from clinicians conducting clinical studies using the CyberKnife registered Robotic Radiosurgery System. Special attention is given to the frameless robotic radiosurgery device known as the CyberKnife, the only image-guided radiosurgery system that utilizes intelligent robotics to track, detect, and correct for changes in tumor position during treatments. Tumors that move with respiration are treated with the CyberKnife using a

  1. Robotic radiosurgery. Treating tumors that move with respiration

    Energy Technology Data Exchange (ETDEWEB)

    Urschel, Harold C. Jr. [Baylor University Medical Center, Dallas, TX (United States). Chair of Cardiovascular and Thoracic Surgical Research, Education and Clinical Excellence; Kresl, John J. [Arizona Oncology Services at St. Joseph' s Hospital and Medical Center, Phoenix, AZ (United States). Dept. of Radiation Oncology; Luketich, James D. [University of Pittsburgh Medical Center PUH, Pittsburgh, PA (United States). The Heart, Lung and Esophageal Surgery Inst.; Papiez, Lech; Timmerman, Robert D. [University of Texas Southwestern Medical Center, Dallas, TX (United States). Dept. of Radiation Oncology; Schulz, Raymond A. (eds.)

    2007-07-01

    Addresses in detail all aspects of the use of robotic radiosurgery to treat tumors of the lung, liver, and pancreas Includes full consideration of tumor tracking techniques, dosimetry, radiobiology, and fiducial placement strategies Written by leading experts Includes many high quality illustrations Stereotactic radiosurgery continues to evolve in ways that allow this powerful technology to reach and treat more tumors in more patients. This volume in the Robotic Radiosurgery series is devoted to theory and practice in the emerging field of stereotactic radiosurgery (also called stereotactic body radiation therapy) for extracranial tumors, particularly those that move as patients breathe. The book is divided into six sections. The first three sections address tumor motion due to respiration and tumor tracking techniques; dosimetry, radiobiology, and imaging; and fiducial placement systems. The fourth and fifth sections then discuss in depth the use of robotic radiosurgery to treat lung and abdominal tumors, respectively, and a final section explains emerging concepts and techniques. Within this framework, detailed information is provided on the technology and methodology for delivery of high doses of radiation to moving targets, radiobiological and radiological principles, and the challenges faced by clinicians performing extracranial stereotactic radiosurgery. Furthermore, there are thorough reviews of the general clinical literature on stereotactic radiation treatment of tumors of the lungs, liver, and pancreas, and the latest clinical data from clinicians conducting clinical studies using the CyberKnife {sup registered} Robotic Radiosurgery System. Special attention is given to the frameless robotic radiosurgery device known as the CyberKnife, the only image-guided radiosurgery system that utilizes intelligent robotics to track, detect, and correct for changes in tumor position during treatments. Tumors that move with respiration are treated with the CyberKnife

  2. SU-F-T-650: The Comparison of Robotic Partial Breast Stereotactic Irradiation Using MLC Vs. Iris Cone

    Energy Technology Data Exchange (ETDEWEB)

    Ding, C; Timmerman, R; Jiang, S; Rahimi, A [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: To evaluate the dosimetric impact on treatment planning for partial breast stereotactic irradiation using Cyberknife with MLC versus Iris Cone. Methods: Ten patients whom underwent lumpectomy for DCIS or stage I invasive non-lobular epithelial breast cancer were included in this study. All patients were previously treated on the Cyberknife using Iris cone with the prescription dose of 37.5Gy in 5 fractions covering at least 95% of PTV on our phase I SBRT 5 fraction partial breast irradiation trial. Retrospectively, treatment planning was performed and compared using the new Cyberknife M6 MLC system for each patient. Using the same contours and critical organ constraints for both MLC and Iris cone plans, the dose on target and critical organs were analyzed accordingly. Results: Dose to critical organs such as ipsilateral lung, contralateral lung, heart, skin, ipsilateral breast, and rib were analyzed, as well as conformity index and high dose spillage of the target area. In 9 of 10 patients, the MLC plans had less total ipsilateral breast volume encompassing the 50% prescription isodose (mean:22.3±8.2% MLC vs. 31.6±8.0 Iris, p=0.00014) .The MLC plans mean estimated treatment delivery time was significantly less than the Iris plans (51±3.9min vs. 56.2±9min, p=0.03) Both MLC and Iris cone plans were able to meet all dose constraints and there was no statistical difference between those dose constraints. Conclusion: Both MLC and Iris Cone can deliver conformal dose to a partial breast target and satisfy the dose constraints of critical organs. The new Cyberknife with MLC can deliver a more conformal dose in the lower dose region and spare more ipsilateral breast tissue to the 50% prescription isodose. The treatment time for partial breast SBRT plans was also reduced using MLC. Project receives research support from Accuray Inc.

  3. Intracranial radiosurgery in the Netherlands. A planning comparison of available systems with regard to physical aspects and workload.

    NARCIS (Netherlands)

    Schoonbeek, A.; Monshouwer, R.; Hanssens, P.; Raaijmakers, E.; Nowak, P.; Marijnissen, J.P.; Lagerwaard, F.J.; Cuijpers, J.P.; Vonk, E.J.; Maazen, R.W.M. van der

    2010-01-01

    Different planning and treatment systems for intracranial stereotactic radiosurgery available in the Netherlands are compared. The systems for intracranial radiosurgery include: Gamma Knife, Cyberknife, Novalis, and Tomotherapy. Electronic data of 5 patients was transferred to all participating

  4. Dosimetry comparison of irradiation with conformal radiotherapy, intensity modulated radiotherapy, conformal radiotherapy in stereotactic conditions and robotic stereotactic radiotherapy for benign brain tumours

    International Nuclear Information System (INIS)

    Spasic, E.; Noel, A.; Buchheit, I.; Bernier, V.

    2011-01-01

    Purpose. - To compare several techniques in order to determine the best treatment for benign brain tumours. Methods and patients. - A retrospective study was performed for five patients who received 3D-conformal radiotherapy, intensity modulated radiotherapy or CyberKnife R . These patients had a meningioma, a pituitary tumour, a cranio-pharyngioma or a neurinoma. In each case, these treatment plans were optimised and compared with the three other dosimetries. Radiobiological or positioning parameters were evaluated, as well as dosimetric parameters, in order to compare treatments with different characteristics. Results. - The dosimetric parameters showed that the choice of treatment seemed to be determined mostly by tumour size, shape and proximity with organs at risk (not tumour localisation). Whereas the results showed no significant deviations with regards to the radiobiological parameters. Therefore, with these parameters, it was difficult to give priority to a treatment. Conclusions. - With regards to benign brain tumours of medium or large size, intensity modulated radiotherapy seemed the recommended treatment. It enabled to obtain a good ratio between efficacy and toxicity for tumours that are really close to organs at risk. Concerning small benign brain tumours, the CyberKnife R was probably the best treatment. (authors)

  5. Dosimetric impacts of endorectal balloon in CyberKnife stereotactic body radiation therapy (SBRT) for early-stage prostate cancer.

    Science.gov (United States)

    Xiang, Hong F; Lu, Hsiao-Ming; Efstathiou, Jason A; Zietman, Anthony L; De Armas, Ricardo; Harris, Kathryn; Bloch, B Nicolas; Qureshi, Muhammad Mustafa; Keohan, Sean; Hirsch, Ariel E

    2017-05-01

    In SBRT for prostate cancer, higher fractional dose to the rectum is a major toxicity concern due to using smaller PTV margin and hypofractionation. We investigate the dosimetric impact on rectum using endorectal balloon (ERB) in prostate SBRT. Twenty prostate cancer patients were included in a retrospective study, ten with ERB and 10 without ERB. Optimized SBRT plans were generated on CyberKnife MultiPlan for 5 × 7.25 Gy to PTV under RTOG-0938 protocol for early-stage prostate cancer. For the rectum and the anterior half rectum, mean dose and percentage of volumes receiving 50%, 80%, 90%, and 100% prescription dose were compared. Using ERB, mean dose to the rectum was 62 cGy (P = 0.001) lower per fraction, and 50 cGy (P = 0.024) lower per fraction for the anterior half rectum. The average V 50% , V 80% , V 90% , and V 100% were lower by 9.9% (P = 0.001), 5.3% (P = 0.0002), 3.4% (P = 0.0002), and 1.2% (P = 0.005) for the rectum, and lower by 10.4% (P = 0.009), 8.3% (P = 0.0004), 5.4% (P = 0.0003), and 2.1% (P = 0.003) for the anterior half rectum. Significant reductions of dose to the rectum using ERB were observed. This may lead to improvement of the rectal toxicity profiles in prostate SBRT. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  6. Dosimetric characterization of hypofractionated Gamma Knife radiosurgery of large or complex brain tumors versus linear accelerator-based treatments.

    Science.gov (United States)

    Dong, Peng; Pérez-Andújar, Angélica; Pinnaduwage, Dilini; Braunstein, Steve; Theodosopoulos, Philip; McDermott, Michael; Sneed, Penny; Ma, Lijun

    2016-12-01

    OBJECTIVE Noninvasive Gamma Knife (GK) platforms, such as the relocatable frame and on-board imaging, have enabled hypofractionated GK radiosurgery of large or complex brain lesions. This study aimed to characterize the dosimetric quality of such treatments against linear accelerator-based delivery systems that include the CyberKnife (CK) and volumetric modulated arc therapy (VMAT). METHODS Ten patients treated with VMAT at the authors' institution for large brain tumors (> 3 cm in maximum diameter) were selected for the study. The median prescription dose was 25 Gy (range 20-30 Gy) in 5 fractions. The median planning target volume (PTV) was 9.57 cm 3 (range 1.94-24.81 cm 3 ). Treatment planning was performed using Eclipse External Beam Planning V11 for VMAT on the Varian TrueBeam system, Multiplan V4.5 for the CyberKnife VSI System, and Leksell GammaPlan V10.2 for the Gamma Knife Perfexion system. The percentage of the PTV receiving at least the prescription dose was normalized to be identical across all platforms for individual cases. The prescription isodose value for the PTV, conformity index, Paddick gradient index, mean and maximum doses for organs at risk, and normal brain dose at variable isodose volumes ranging from the 5-Gy isodose volume (V5) to the 15-Gy isodose volume (V15) were compared for all of the cases. RESULTS The mean Paddick gradient index was 2.6 ± 0.2, 3.2 ± 0.5, and 4.3 ± 1.0 for GK, CK, and VMAT, respectively (p 0.06). The average prescription isodose values were 52% (range 47%-69%), 60% (range 46%-68%), and 88% (range 70%-94%) for GK, CK, and VMAT, respectively, thus producing significant variations in dose hot spots among the 3 platforms. Furthermore, the mean V5 values for GK and CK were similar (p > 0.79) at 71.9 ± 36.2 cm 3 and 73.3 ± 31.8 cm 3 , respectively, both of which were statistically lower (p linear accelerator-based treatments. Such a result supports the use of a large number of isocenters or confocal beams for the

  7. Image-guided robotic radiosurgery for spinal metastases

    International Nuclear Information System (INIS)

    Gibbs, Iris C.; Kamnerdsupaphon, Pimkhuan; Ryu, Mi-Ryeong; Dodd, Robert; Kiernan, Michaela; Chang, Steven D.; Adler, John R.

    2007-01-01

    Background and Purpose: To determine the effectiveness and safety of image-guided robotic radiosurgery for spinal metastases. Materials/Methods: From 1996 to 2005, 74 patients with 102 spinal metastases were treated using the CyberKnife TM at Stanford University. Sixty-two (84%) patients were symptomatic. Seventy-four percent (50/68) of previously treated patients had prior radiation. Using the CyberKnife TM , 16-25 Gy in 1-5 fractions was delivered. Patients were followed clinically and radiographically for at least 3 months or until death. Results: With mean follow-up of 9 months (range 0-33 months), 36 patients were alive and 38 were dead at last follow-up. No death was treatment related. Eighty-four (84%) percent of symptomatic patients experienced improvement or resolution of symptoms after treatment. Three patients developed treatment-related spinal injury. Analysis of dose-volume parameters and clinical parameters failed to identify predictors of spinal cord injury. Conclusions: Robotic radiosurgery is effective and generally safe for spinal metastases even in previously irradiated patients

  8. SU-E-T-604: Penumbra Characteristics of a New InCiseâ„¢ Multileaf Collimator of CyberKnife M6â„¢ System

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, M; Jang, S; Ozhasoglu, C; Lalonde, R; Heron, D; Huq, M [University of Pittsburgh Medical Center, Pittsburgh, PA (United States)

    2015-06-15

    Purpose: The InCise™ Multileaf Collimator (MLC) of CyberKnife M6™ System has been released recently. The purpose of this study was to explore the dosimetric characteristics of the new MLC. In particular, the penumbra characteristics of MLC fields at varying locations are evaluated. Methods: EBT3-based film measurements were performed with varying MLC fields ranging from 7.5 mm to 27.5 mm. Seventeen regions of interests (ROIs) were identified for irradiation. These are regions located at the central area (denoted as reference field), at the left/right edge areas of reference open field, at an intermediate location between central and edge area. Single beam treatment plans were designed by using the MultiPlan and was delivered using the Blue Phantom. Gafchromic films were irradiated at 1.5 cm depth in the Blue Phantom and analyzed using the Film Pro software. Variation of maximum dose, penumbra of MLC-defined fields, and symmetry/flatness were calculated as a function of locations of MLC fields. Results: The InCise™ MLC System showed relatively consistent dose distribution and penumbra size with varying locations of MLC fields. The measured maximum dose varied within 5 % at different locations compared to that at the central location and agreed with the calculated data well within 2%. The measured penumbrae were in the range of 2.9 mm and 3.7 mm and were relatively consistent regardless of locations. However, dose profiles in the out-of-field and in-field regions varied with locations and field sizes. Strong variation was seen for all fields located at 55 mm away from the central field. The MLC leakage map showed that the leakage is dependent on position. Conclusion: The size of penumbra and normalized maximum dose for MLC-defined fields were consistent in different regions of MLC. However, dose profiles in the out-field region varied with locations and field sizes.

  9. SU-E-T-604: Penumbra Characteristics of a New InCiseâ„¢ Multileaf Collimator of CyberKnife M6â„¢ System

    International Nuclear Information System (INIS)

    Hwang, M; Jang, S; Ozhasoglu, C; Lalonde, R; Heron, D; Huq, M

    2015-01-01

    Purpose: The InCise™ Multileaf Collimator (MLC) of CyberKnife M6™ System has been released recently. The purpose of this study was to explore the dosimetric characteristics of the new MLC. In particular, the penumbra characteristics of MLC fields at varying locations are evaluated. Methods: EBT3-based film measurements were performed with varying MLC fields ranging from 7.5 mm to 27.5 mm. Seventeen regions of interests (ROIs) were identified for irradiation. These are regions located at the central area (denoted as reference field), at the left/right edge areas of reference open field, at an intermediate location between central and edge area. Single beam treatment plans were designed by using the MultiPlan and was delivered using the Blue Phantom. Gafchromic films were irradiated at 1.5 cm depth in the Blue Phantom and analyzed using the Film Pro software. Variation of maximum dose, penumbra of MLC-defined fields, and symmetry/flatness were calculated as a function of locations of MLC fields. Results: The InCise™ MLC System showed relatively consistent dose distribution and penumbra size with varying locations of MLC fields. The measured maximum dose varied within 5 % at different locations compared to that at the central location and agreed with the calculated data well within 2%. The measured penumbrae were in the range of 2.9 mm and 3.7 mm and were relatively consistent regardless of locations. However, dose profiles in the out-of-field and in-field regions varied with locations and field sizes. Strong variation was seen for all fields located at 55 mm away from the central field. The MLC leakage map showed that the leakage is dependent on position. Conclusion: The size of penumbra and normalized maximum dose for MLC-defined fields were consistent in different regions of MLC. However, dose profiles in the out-field region varied with locations and field sizes

  10. SU-E-T-453: A Novel Daily QA System for Robotic Image Guided Radiosurgery with Variable Aperture Collimator

    International Nuclear Information System (INIS)

    Wang, L; Nelson, B

    2014-01-01

    Purpose: A novel end-to-end system using a CCD camera and a scintillator based phantom that is capable of measuring the beam-by-beam delivery accuracy of Robotic Radiosurgery has been developed and reported in our previous work. This work investigates its application to end-to-end type daily QA for Robotic Radiosurgery (Cyberknife) with Variable Aperture Collimator (Iris). Methods: The phantom was first scanned with a CT scanner at 0.625 slice thickness and exported to the Cyberknife Muliplan (v4.6) treatment planning system. An isocentric treatment plan was created consisting of ten beams of 25 Monitor Units each using Iris apertures of 7.5, 10, 15, 20, and 25 mm. The plan was delivered six times in two days on the Cyberknife G4 system with fiducial tracking on the four metal fiducials embedded in phantom with re-positioning between the measurements. The beam vectors (X, Y, Z) are measured and compared with the plan from the machine delivery file (XML file). The Iris apertures (FWHM) were measured from the beam flux map and compared with the commissioning data. Results: The average beam positioning accuracies of the six deliveries are 0.71 ± 0.40 mm, 0.72 ± 0.44 mm, 0.74 ± 0.42 mm, 0.70 ± 0.40 mm, 0.79 ± 0.44 mm and 0.69 ± 0.41 mm respectively. Radiation beam width (FWHM) variations are within ±0.05 mm, and they agree with the commissioning data within 0.22 mm. The delivery time for the plan is about 7 minutes and the results are given instantly. Conclusion: The experimental results agree with stated sub-millimeter delivery accuracy of Cyberknife system. Beam FWHM variations comply with the 0.2 mm accuracy of the Iris collimator at SAD. The XRV-100 system has proven to be a powerful tool in performing end-to-end type tests for Robotic Image Guided Radiosurgery Daily QA

  11. Patient-specific quality assurance for intracranial cases in robotic radiosurgery system.

    Science.gov (United States)

    Koksal, Canan; Akbas, Ugur; Donmez Kesen, Nazmiye; Okutan, Murat; Bilge, Hatice; Kemikler, Gonul

    2018-01-01

    The purpose of this study was to perform pretreatment patient-specific quality assurance (QA) for intracranial irradiation using CyberKnife with an ion chamber. Twenty-five intracranial plans created using the ray-tracing algorithm were used for this study. Computed tomography (CT) images of the water-equivalent RW3 slab phantom with PinPoint ionization chamber were acquired with 1-mm slice thickness and transferred to the MultiPlan treatment planning system (TPS). Four gold fiducial markers embedded into two different plates were used to tracking during the irradiation. Intracranial plans were transferred to CT images of the RW3 phantom. The isodose curves and sensitive volume of ion chamber were overlapped. Point dose measurements were performed three times and the mean point doses were calculated for each plan. The mean doses measured by the PinPoint ion chamber were compared with those of the calculated by MultiPlan TPS in the sensitive volume of PinPoint. The mean percentage difference (MPD) in point dose measurements was -2.44±1.97 for 25 plans. The maximum and minimum percentage differences between the measured and calculated absolute point doses were -7.14 and 0.23, respectively. The MPD was -1.70±1.90 for 12 plans using a fixed collimator and -3.11±1.86 for 13 plans using an IRIS cone. Point dose measurement is a reliable and functional method for pre-treatment patient-specific QA in intracranial CyberKnife plans. Point dose verification should be performed to correct any possible errors prior to patient treatment. It is recommended for use in patient-specific QA process in the CyberKnife plans.

  12. Stereotactic Radiosurgery and Fractionated Stereotactic Radiation Therapy for the Treatment of Uveal Melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Yazici, Gozde [Department of Radiation Oncology, Faculty of Medicine, Hacettepe University, Ankara (Turkey); Kiratli, Hayyam [Department of Ophthalmology, Faculty of Medicine, Hacettepe University, Ankara (Turkey); Ozyigit, Gokhan; Sari, Sezin Yuce; Cengiz, Mustafa [Department of Radiation Oncology, Faculty of Medicine, Hacettepe University, Ankara (Turkey); Tarlan, Bercin [Bascom Palmer Eye Institute, Miami, Florida (United States); Mocan, Burce Ozgen [Department of Radiology, Faculty of Medicine, Hacettepe University, Ankara (Turkey); Zorlu, Faruk, E-mail: fzorlu@hacettepe.edu.tr [Department of Radiation Oncology, Faculty of Medicine, Hacettepe University, Ankara (Turkey)

    2017-05-01

    Purpose: To evaluate treatment results of stereotactic radiosurgery or fractionated stereotactic radiation therapy (SRS/FSRT) for uveal melanoma. Methods and Materials: We retrospectively evaluated 181 patients with 182 uveal melanomas receiving SRS/FSRT between 2007 and 2013. Treatment was administered with CyberKnife. Results: According to Collaborative Ocular Melanoma Study criteria, tumor size was small in 1%, medium in 49.5%, and large in 49.5% of the patients. Seventy-one tumors received <45 Gy, and 111 received ≥45 Gy. Median follow-up time was 24 months. Complete and partial response was observed in 8 and 104 eyes, respectively. The rate of 5-year overall survival was 98%, disease-free survival 57%, local recurrence-free survival 73%, distant metastasis-free survival 69%, and enucleation-free survival 73%. There was a significant correlation between tumor size and disease-free survival, SRS/FSRT dose and enucleation-free survival; and both were prognostic for local recurrence-free survival. Enucleation was performed in 41 eyes owing to progression in 26 and complications in 11. Conclusions: The radiation therapy dose is of great importance for local control and eye retention; the best treatment outcome was achieved using ≥45 Gy in 3 fractions.

  13. Stereotactic Radiosurgery and Fractionated Stereotactic Radiation Therapy for the Treatment of Uveal Melanoma

    International Nuclear Information System (INIS)

    Yazici, Gozde; Kiratli, Hayyam; Ozyigit, Gokhan; Sari, Sezin Yuce; Cengiz, Mustafa; Tarlan, Bercin; Mocan, Burce Ozgen; Zorlu, Faruk

    2017-01-01

    Purpose: To evaluate treatment results of stereotactic radiosurgery or fractionated stereotactic radiation therapy (SRS/FSRT) for uveal melanoma. Methods and Materials: We retrospectively evaluated 181 patients with 182 uveal melanomas receiving SRS/FSRT between 2007 and 2013. Treatment was administered with CyberKnife. Results: According to Collaborative Ocular Melanoma Study criteria, tumor size was small in 1%, medium in 49.5%, and large in 49.5% of the patients. Seventy-one tumors received <45 Gy, and 111 received ≥45 Gy. Median follow-up time was 24 months. Complete and partial response was observed in 8 and 104 eyes, respectively. The rate of 5-year overall survival was 98%, disease-free survival 57%, local recurrence-free survival 73%, distant metastasis-free survival 69%, and enucleation-free survival 73%. There was a significant correlation between tumor size and disease-free survival, SRS/FSRT dose and enucleation-free survival; and both were prognostic for local recurrence-free survival. Enucleation was performed in 41 eyes owing to progression in 26 and complications in 11. Conclusions: The radiation therapy dose is of great importance for local control and eye retention; the best treatment outcome was achieved using ≥45 Gy in 3 fractions.

  14. TU-F-CAMPUS-J-01: Inference of Prostate PTV Margins in VMAT Delivery From Intra-Fraction Prostate Motion During SBRT Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Thind, K; Wong, R; Gerdes, C; Chow, T [Juravinski Cancer Centre, Hamilton, Ontario (Canada); Wong, D [McMaster University, Hamilton, Ontario (Canada)

    2015-06-15

    Purpose: To retrospectively quantify the intra-fraction prostate motion during stereotactic body radiation therapy (SBRT) treatment using CyberKnife’s target tracking system, which may provide insight into expansion margins from GTV to PTV used in gantry-based treatments. CyberKnife is equipped with an active tracking system (InTempo) that tracks the four fiducials placed in the prostate gland. The system acquires intra-fraction orthogonal kV images at 45° and 315° in a sequential fashion. Methods: A total of 38 patients treated with SBRT using CyberKnife between 2011 and 2013 were studied. Dose-regime was 36.25 Gy in 5 fractions (7.25 Gy/fraction, twice per week) as per RTOG 0938 guidelines. The CyberKnife image tracking logs for all SBRT treatments using InTempo were examined. A total of 13663 images were examined for the superior/inferior (SI), anterior/posterior (AP) and left/right (LR) translation as well as roll, pitch and yaw rotations for the target position relative to the last known model position. Results: The mean ± 2 SD of intra-fraction motion was contained within 3 mm for SI and LR and 4.5 mm for AP directions at 5 minutes into the treatment delivery. It was contained within 4 mm for SI and LR and 5 mm for AP at 10 minutes. At 15 minutes into delivery, all translations were contained within 5 mm. The mean ± 2 SD of prostate roll, pitch and yaw increased with time but were contained within 5 degree at 5, 10 and 15 minutes into treatment. Additionally, target translations and rotations were within ± 1 mm and ± 1 degree for 90% and 78% of the time. Conclusion: The organ motion component of PTV margin for 10 minute VMAT delivery is contained within 4 mm in SI and LR direction and within 5 mm in the AP direction.

  15. SU-F-T-569: Implementation of a Patient Specific QA Method Using EBT-XD for CyberKnife SRS/SBRT Plans

    Energy Technology Data Exchange (ETDEWEB)

    Zerouali, K; Aubry, J; Doucet, R [Centre hospitalier de l’Universite de Montreal, Montreal, Quebec (Canada)

    2016-06-15

    Purpose: To implement the new EBT-XD Gafchromic films for accurate dosimetric and geometric validation of stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) CyberKnife (CK) patient specific QA. Methods: Film calibration was performed using a triplechannel film analysis on an Epson 10000XL scanner. Calibration films were irradiated using a Varian Clinac 21EX flattened beam (0 to 20 Gy), to ensure sufficient dose homogeneity. Films were scanned to a resolution of 0.3 mm, 24 hours post irradiation following a well-defined protocol. A set of 12 QA was performed for several types of CK plans: trigeminal neuralgia, brain metastasis, prostate and lung tumors. A custom made insert for the CK head phantom has been manufactured to yield an accurate measured to calculated dose registration. When the high dose region was large enough, absolute dose was also measured with an ionization chamber. Dose calculation is performed using MultiPlan Ray-tracing algorithm for all cases since the phantom is mostly made from near water-equivalent plastic. Results: Good agreement (<2%) was found between the dose to the chamber and the film, when a chamber measurement was possible The average dose difference and standard deviations between film measurements and TPS calculations were respectively 1.75% and 3%. The geometric accuracy has been estimated to be <1 mm, combining robot positioning uncertainty and film registration to calculated dose. Conclusion: Patient specific QA measurements using EBT-XD films yielded a full 2D dose plane with high spatial resolution and acceptable dose accuracy. This method is particularly promising for trigeminal neuralgia plan QA, where the positioning of the spatial dose distribution is equally or more important than the absolute delivered dose to achieve clinical goals.

  16. Variable Circular Collimator in Robotic Radiosurgery: A Time-Efficient Alternative to a Mini-Multileaf Collimator?

    International Nuclear Information System (INIS)

    Water, Steven van de; Hoogeman, Mischa S.; Breedveld, Sebastiaan; Nuyttens, Joost J.M.E.; Schaart, Dennis R.; Heijmen, Ben J.M.

    2011-01-01

    Purpose: Compared with many small circular beams used in CyberKnife treatments, beam's eye view-shaped fields are generally more time-efficient for dose delivery. However, beam's eye view-shaping devices, such as a mini-multileaf collimator (mMLC), are not presently available for CyberKnife, although a variable-aperture collimator (Iris, 12 field diameters; 5-60 mm) is available. We investigated whether the Iris can mimic noncoplanar mMLC treatments using a limited set of principal beam orientations (nodes) to produce time-efficient treatment plans. Methods and Materials: The data from 10 lung cancer patients and the beam-orientation optimization algorithm 'Cycle' were used to generate stereotactic treatment plans (3 x 20 Gy) for a CyberKnife virtually equipped with a mMLC. Typically, 10-16 favorable beam orientations were selected from 117 available robot node positions using beam's eye view-shaped fields with uniform fluence. Second, intensity-modulated Iris plans were generated by inverse optimization of nonisocentric circular candidate beams targeted from the same nodes selected in the mMLC plans. The plans were evaluated using the mean lung dose, lung volume receiving ≥20 Gy, conformality index, number of nodes, beams, and monitor units, and estimated treatment time. Results: The mMLC plans contained an average of 12 nodes and 11,690 monitor units. For a comparable mean lung dose, the Iris plans contained 12 nodes, 64 beams, and 21,990 monitor units. The estimated fraction duration was 12.2 min (range, 10.8-13.5) for the mMLC plans and 18.4 min (range, 12.9-28.5) for the Iris plans. In contrast to the mMLC plans, the treatment time for the Iris plans increased with an increasing target volume. The Iris plans were, on average, 40% longer than the corresponding mMLC plans for small targets ( 3 ) and ≤121% longer for larger targets. For a comparable conformality index, similar results were obtained. Conclusion: For stereotactic lung irradiation, time

  17. The current role of Gamma Knife radiosurgery in the management of intracranial haemangiopericytoma.

    Science.gov (United States)

    Spina, Alfio; Boari, Nicola; Gagliardi, Filippo; Donofrio, Carmine A; Franzin, Alberto; Mortini, Pietro

    2016-04-01

    Haemangiopericytomas (HPCs) are rare tumours characterised by aggressive behaviour with tendency to local recurrence and to metastasise. WHO grade II and grade III tumours show different progression-free survival and overall survival rates. Gross total tumour resection is still considered the treatment of choice. Adjuvant radiation therapies represent an option in the treatment strategy regardless the extent of resection. Based on this consideration, Gamma Knife radiosurgery has been introduced either as a primary treatment or as an adjuvant treatment for residual or recurrent tumours. A systematic search was performed on PubMed, Web of Science and Google Scholar for clinical series reporting Gamma Knife radiosurgery, Cyberknife and Linear Accelerator (LINAC) for the management of intracranial HPCs. Fourteen studies focusing on the effects of Gamma Knife radiosurgery for intracranial HPCs were included. Four studies reported data on Cyberknife radiosurgery and LINAC. A total of 208 patients harbouring 366 tumours have been reported. Patient's features, radiosurgical treatment characteristics and follow-up data of the pertinent literature have been critically revised. Gamma Knife radiosurgery and the other radiosurgical techniques represent a feasible and effective therapy in the management of HPCs. Tumour control and survival rate are comparable to those reported for radiotherapy. Further studies should be focused to define the exact role of Gamma Knife radiosurgery in the management of HPCs.

  18. SU-E-T-804: Verification of the BJR-25 Method of KQ Determination for CyberKnife Absolute Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Gersh, J [Gibbs Cancer Center & Research Institute - Pelham, Greer, SC (United States); Spectrum Medical Physics, LLC - Greenville, SC (United States); Willett, B [Accuray, Inc., Sunnyvale, CA (United States)

    2015-06-15

    Purpose: Absolute calibration of the CyberKnife is performed using a 6cm-diameter cone defined at 80cm SAD. Since kQ is defined using PDD values determined using 10×10 cm fields at 100cm SSD, the PDD must be corrected in order to correctly apply the quality conversion factor. The accepted method is based on equivalent field-size conversions of PDD values using BJR25. Using the new InCise MLC system, the CK is capable of generating a rectangular field equivalent to 10×10 cm square field. In this study, a comparison is made between kQ values determined using the traditional BJR25 method and the MLC method introduced herein. Methods: First, kQ(BJR) is determined: a PDD is acquired using a 6cm circular field at 100cm SSD, its field size converted to an equivalent square, and PDD converted to a 10×10cm field using the appropriate BJR25 table. Maintaining a consistent setup, the collimator is changed, and the MLC method is used. Finally, kQ is determined using PDDs acquired with a 9.71×10.31cm at 100cm SSD. This field is produced by setting the field to a size of 7.77×8.25cm (since it is defined at 80cm SAD). An exact 10×10cm field since field size is relegated to increments of its leaf width (0.25cm). This comparison is made using an Exradin A1SL, IBA CC08, IBA CC13, and an Exradin A19. For each detector and collimator type, the beam injector was adjusted to give 5 different beam qualities; representing a range of clinical systems. Results: Averaging across all beam qualities, kQ(MLC) differed from kQ(BJR) by less than 0.15%. The difference between the values increased with detector volume. Conclusion: For CK users with standard cone collimators, the BJR25 method has been verified. For CK users the MLC system, a technique is described to determine kQ. Primary author is the President/Owner of Spectrum Medical Physics, LLC, a company which maintains contracts with Siemens Healthcare and Standard Imaging, Inc.

  19. Clinical and Treatment Features of Orbital Neurogenic Tumors

    Directory of Open Access Journals (Sweden)

    Pınar Bingöl Kızıltunç

    2013-10-01

    Full Text Available Purpose: To evaluate the clinical and treatment features of orbital neurogenic tumors. Material and Method: The records of 35 patients with orbital neurogenic tumors who were diagnosed and treated at Ankara University Faculty of Medicine, Department of Ophthalmology, between 1998 and 2011 were evaluated retrospectively. Results: Orbitotomy via a cutaneous approach was performed in 21 (60% cases and orbitotomy via a transconjunctival approach was performed in 7 (20% cases. Three (8% cases had been operated at different centers. Four (12% cases were diagnosed clinically. Total excisional biopsy was performed in 11 (31.4% cases, subtotal excisional biopsy was performed in 7 (20%, and incisional biopsy was performed in 10 (28.6% cases. 14 (40% 35 cases were diagnosed as meningioma, 12 (34% as peripheral nerve sheath tumor, and 9 (26% cases were diagnosed as optic nerve glioma. Six (43% meningioma cases were optic nerve sheath meningioma, 5 (36% were sphenoid wing meningioma, 2 (14% were ectopic meningioma, and 1 (7% was perisellar meningioma. Six (50% of peripheral nerve sheath tumors were schwannoma, 2 (16% were solitary neurofibroma, 4 (34% were plexiform neurofibroma. External beam radiotherapy was performed in 15 (42.8% cases, cyberknife radiosurgery in 1 (2.8% , chemotherapy in 1 (2.8%, and enucleation ( because of neovascular glaucoma and vitreous hemorrhage was performed in 1 (2.8% case. Discussion: The most common orbital neurogenic tumors are meningioma, peripheral nerve sheath tumor, and optic nerve glioma. For meningioma and glioma, external beam radiotherapy is required; for schwannoma and solitary neurofibroma, total excisional biopsy is the preferred treatment. The success of visual and anatomic results are high after treatment. (Turk J Ophthalmol 2013; 43: 335-9

  20. Treatment and technical intervention time analysis of a robotic stereotactic radiotherapy system.

    Science.gov (United States)

    Crop, F; Lacornerie, T; Szymczak, H; Felin, A; Bailleux, C; Mirabel, X; Lartigau, E

    2014-02-01

    The purpose of this study is to obtain a better operational knowledge of Stereotactic Body Radiotherapy (SBRT) treatments with CyberKnife(r). An analysis of both In-room Times (IRT) and technical interventions of 5 years of treatments was performed, during which more than 1600 patients were treated for various indications, including liver (21%), lung (29%), intracranial (13%), head and neck (11%) and prostate (7%). Technical interventions were recorded along with the time of the failure, time to the intervention, and the complexity and duration of the repair. Analyses of Time Between Failures (TBF) and Service Disrupting TBF(disr) were performed. Treatment time data and variability per indication and following different system upgrades were evaluated. Large variations of IRTs were found between indications, but also large variations for each indication. The combination of the time reduction Tool (using Iris(r)) and Improved Stop Handling was of major impact to shortening of treatment times. The first implementation of the Iris collimator alone did not lead to significantly shorter IRTs for us except during prostate treatments. This was mostly due to the addition at the same time of larger rotational compensation for prostate treatments (58 instead of 1.58). Significant differences of duration between the first fraction and following fractions of a treatment, representing the necessity of defining imaging parameters and explanation to patients, were found for liver (12 min) and lung treatments using Xsight(r) Spine (5 min). Liver and lung treatments represent the longest IRT's and involve the largest variability's in IRT. The malfunction rate of the system followed a Weibull distribution with the shape and scale parameters of 0.8 and 39.7. Mean TBF(disr) was 68 work hours. 60 to 80% of the service disrupting interventions were resolved within 30-60 min, 5% required external intervention and 30% occurred in the morning. The presented results can be applied in the

  1. Re-irradiation in stereotactic conditions and cetuximab for local relapses of epidermoid carcinoma of head and neck; Reirradiation en conditions stereotaxiques et cetuximab pour des recidives locales de carcinome epidermoide de la tete et du cou

    Energy Technology Data Exchange (ETDEWEB)

    Vasseur, F.; Comet, B.; Faivre-Pierret, M.; Coche-Dequeant, B.; Degardin, M.; Lefebvre, J.L.; Lacornerie, T.; Lartigau, E. [Departement universitaire de radiotherapie, centre Oscar Lambret, 59 - Lille (France); Universite Lille-2, 59 (France)

    2010-10-15

    The authors report a work aimed at assessing the feasibility and toxicity of a re-irradiation treatment in stereotactic conditions using CyberKnife and cetuximab in the case of local relapses of epidermoid cancers of the ORL sphere. Thirty three patients have been submitted to this treatment between June 2007 and April 2009. Although six patients died by six months, this treatment seems to be a good alternative, and presents an acceptable short-term toxicity. Further studies are needed to compare this technique to other therapeutic techniques, and to assess the risk of long term complications. Short communication

  2. Hypofractionated stereotactic body radiotherapy in low- and intermediate-risk prostate carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hun Jung; Phak, Jeong Hoon; Kim, Woo Chul [Dept. of Radiation Oncology, Inha University Hospital, Inha University School of Medicine, Incheon (Korea, Republic of)

    2016-12-15

    Stereotactic body radiotherapy (SBRT) takes advantage of low α/β ratio of prostate cancer to deliver a large dose in few fractions. We examined clinical outcomes of SBRT using CyberKnife for the treatment of low- and intermediate-risk prostate cancer. This study was based on a retrospective analysis of the 33 patients treated with SBRT using CyberKnife for localized prostate cancer (27.3% in low-risk and 72.7% in intermediate-risk). Total dose of 36.25 Gy in 5 fractions of 7.25 Gy were administered. The acute and late toxicities were recorded using the Radiation Therapy Oncology Group scale. Prostate-specific antigen (PSA) response was monitored. Thirty-three patients with a median 51 months (range, 6 to 71 months) follow-up were analyzed. There was no biochemical failure. Median PSA nadir was 0.27 ng/mL at median 33 months and PSA bounce occurred in 30.3% (n = 10) of patients at median at median 10.5 months after SBRT. No grade 3 acute toxicity was noted. The 18.2% of the patients had acute grade 2 genitourinary (GU) toxicities and 21.2% had acute grade 2 gastrointestinal (GI) toxicities. After follow-up of 2 months, most complications had returned to baseline. There was no grade 3 late GU and GI toxicity. Our experience with SBRT using CyberKnife in low- and intermediate-risk prostate cancer demonstrates favorable efficacy and toxicity. Further studies with more patients and longer follow-up duration are required.

  3. Three-dimensional power doppler ultrasound is useful to monitor the response to treatment in a patient with primary papillary serous carcinoma of the peritoneum.

    Science.gov (United States)

    Su, Jen-Min; Huang, Yu-Fang; Chen, Helen H W; Cheng, Ya-Min; Chou, Cheng-Yang

    2006-05-01

    To date, this is the first report to monitor changes of intratumor vascularization and the response to radiation and Cyberknife therapy in a patient with recurrent primary papillary serous carcinoma of the peritoneum by three dimensional (3D) power Doppler ultrasonography (PDUS). Transvaginal 3D PDUS detected a recurrent presacral tumor with abundant intratumor vascularity. Serial examinations of the tumor volume and serum CA-125 level were studied before, during, and 6 mo after therapy. Meanwhile, the intratumor blood flow was measured and expressed as vascularity indices. All of the tumor volume, intratumor vascularity indices and serum CA-125 level decreased progressively following therapy. A remaining lesion with nearly absent intratumor power Doppler signals suggested a scarring lesion posttreatment. Indeed, CT-guided tissue biopsy confirmed fibrotic change. 3D PDUS is useful to monitor the response to treatments and to differentiate residual tumors from lesions of scarring change posttreatment. It provides more accurate posttreatment information than pelvic computed tomography.

  4. Successful long-term treatment of Cushing disease with mifepristone (RU486).

    Science.gov (United States)

    Basina, Marina; Liu, Hau; Hoffman, Andrew R; Feldman, David

    2012-01-01

    We describe a girl with Cushing disease for whom surgery and radiation treatments failed and the subsequent clinical course with mifepristone therapy. We present the patient's clinical, biochemical, and imaging findings. A 16-year-old girl presented with classic Cushing disease. After transsphenoidal surgery, Cyberknife radiosurgery, ketoconazole, and metyrapone did not control her disease, and she was prescribed mifepristone, which was titrated to a maximal dosage of 1200 mg daily with subsequent symptom improvement. Mifepristone (RU486) is a high-affinity, nonselective antagonist of the glucocorticoid receptor. There is limited literature on its use as an off-label medication to treat refractory Cushing disease. Over her 8-year treatment with mifepristone, her therapy was complicated by hypertension and hypokalemia requiring spironolactone and potassium chloride. She received a 2-month drug holiday every 4 to 6 months to allow for withdrawal menstrual bleeding with medroxyprogesterone acetate. Urinary cortisol, serum cortisol, and corticotropin levels remained elevated during mifepristone drug holidays. While on mifepristone, her signs and symptoms of Cushing disease resolved. Repeated magnetic resonance imaging demonstrated stable appearance of the residual pituitary mass. Bilateral adrenalectomy was performed, and mifepristone was discontinued after 95 months of medical therapy. We describe the longest duration of mifepristone therapy thus reported for the treatment of refractory Cushing disease. Mifepristone effectively controlled all signs and symptoms of hypercortisolism. Menstruating women who take the drug on a long-term basis should receive periodic drug holidays to allow for menses. The lack of reliable serum biomarkers to monitor the success of mifepristone therapy requires careful clinical judgment and may make its use difficult in Cushing disease.

  5. SU-F-T-420: Dosimetry Comparison of Advanced External Beam Radiation Treatment Modalities to Brachytherapy Treatments in Patients with Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Mwidu, U; Devic, S [McGill University, Montreal, QC (Canada); Shehadeh, M; AlKafi, M; Mahmood, R; Moftah, B [King Faisal Specialist Hospital & Research Center, Riyadh, Riyadh (Saudi Arabia)

    2016-06-15

    Purpose: A retrospective comparison of dose distributions achievable by High dose rate brachytherapy (HDRBT), Helical TomoTherapy (TOMO), CyberKnife (CK) and RapidArc (RA) in locally advanced inoperable cervical cancer patients is presented. Methods: Five patients with advanced stage cervical carcinoma were selected for this study after a full course of external beam radiotherapy (EBRT), chemotherapy and HDR Brachytherapy. To highlight any significant similarities/differences in dose distributions, high-risk clinical target volume (HRCTV) coverage, organs at risk (OAR) sparing, and machine specific delivery limitations, we used D90 (dose received by 90% of the volume) as the parameter for HRCTV coverage as recommended by the GEC-ESTRO Working Group. We also compared both integral and differential dose volume histograms (DVH) between different dose distributions treatment modalities for HRCTV and OAR. Results: TOMO and RA provided the most conformal dose distributions to HRCTV. Median doses (in Gy) to organs at risk were; for rectal wall: 1.7±0.6, 2.5±0.6,1.2±0.3, and 1.5±0.6, and for bladder wall: 1.6±0.1, 2.4±0.4, 0.8±0.6, and 1.5±0.5, for HDRBT, TOMO, CK, and RA, respectively. Conclusion: Contemporary EBRT modalities might be able to replace brachytherapy treatments for cervix cancer. While brachytherapy dose distributions feature high dose gradients, EBRT modalities provide highly conformal dose distributions to the target. However, it is still not clear whether a highly conformal dose or high gradient dose is more clinically relevant for the HRCTV in cervix cancer patients.

  6. Monte Carlo simulated corrections for beam commissioning measurements with circular and MLC shaped fields on the CyberKnife M6 System: a study including diode, microchamber, point scintillator, and synthetic microdiamond detectors

    Science.gov (United States)

    Francescon, P.; Kilby, W.; Noll, J. M.; Masi, L.; Satariano, N.; Russo, S.

    2017-02-01

    Monte Carlo simulation was used to calculate correction factors for output factor (OF), percentage depth-dose (PDD), and off-axis ratio (OAR) measurements with the CyberKnife M6 System. These include the first such data for the InCise MLC. Simulated detectors include diodes, air-filled microchambers, a synthetic microdiamond detector, and point scintillator. Individual perturbation factors were also evaluated. OF corrections show similar trends to previous studies. With a 5 mm fixed collimator the diode correction to convert a measured OF to the corresponding point dose ratio varies between  -6.1% and  -3.5% for the diode models evaluated, while in a 7.6 mm  ×  7.7 mm MLC field these are  -4.5% to  -1.8%. The corresponding microchamber corrections are  +9.9% to  +10.7% and  +3.5% to  +4.0%. The microdiamond corrections have a maximum of  -1.4% for the 7.5 mm and 10 mm collimators. The scintillator corrections are  15%, reducing to    d max were  M6 Systems and retrospectively checking estimated corrections used previously. We recommend the PDD and OAR corrections are used to guide detector selection and inform the evaluation of results rather than to explicitly correct measurements.

  7. SU-F-T-481: Physics Evaluation of a Newly Released InCise™ Multileaf Collimator for CyberKnife M6™ System

    Energy Technology Data Exchange (ETDEWEB)

    Wang, L; Chin, E; Lo, A [Stanford University Cancer Center, Stanford, CA (United States)

    2016-06-15

    Purpose: This work reports the results of the physics evaluation of a newly released InCise™2 Multileaf Collimator (MLC) installed in our institution. Methods: Beam property data was measured with unshielded diode and EBT2 films. The measurements included MLC leaf transmission, beam profiles, output factors and tissue-phantom ratios. MLC performance was evaluated for one month after commissioning. Weekly Garden Fence tests were performed for leaf / bank positioning in standard (A/P) and clinically relevant non-standard positions, before and after MLC driving exercises of 10+ minutes. Daily Picket Fence test and AQA test, End-to-End tests and dosimetric quality assurance were performed to evaluate the overall system performance. Results: All measurements including beam energy, flatness and symmetry, were within manufacture specifications. Leaf transmission was 0.4% <0.5% specification. The values of output factors ranged from 0.825 (7.6 mm × 7.5 mm) to 1.026 (115.0 mm × 100.1 mm). Average beam penumbra at 10 cm depth ranged from 2.7mm/2.7mm(7.6 mm × 7.5 mm) to 6.0 mm/6.2mm(84.6 mm × 84.7 mm). Slight penumbra difference (<10% from average penumbra for fields >20 mm) was observed in the direction perpendicular to leaf motion due to the tilting of the leaf housing. Mean leaf position offsets was −0.08±0.07mm and −0.13 ± 0.08 for X1 and X2 leaf banks in 13 Garden Fence tests. No significant difference on average leaf positioning offsets was observed between different leaf orientations and before/after MLC driving exercises. Six End-to-End tests showed 0.43±0.23mm overall targeting accuracy. Picket-Fence and AQA showed stable performance of MLC during the test period. Dosimetric point dose measurements for test cases agreed with calculation within 3%. All film measurements on relative dose had Gamma (2%, 2mm) passing rate of >95%. Conclusion: The Incise™2 MLC for CyberKnife M6™ was proven to be accurate and reliable, and it is currently in clinical use

  8. Role of external radiotherapy when taking into care hepatic metastases; Place de la radiotherapie externe dans la prise en charge des metastases hepatiques

    Energy Technology Data Exchange (ETDEWEB)

    Dietmann, A.S.; Taste-Geroge, H.; Peiffert, D. [Centre Alexis-Vautrin, 54 - Nancy (France)

    2010-10-15

    After having indicated the various origins of hepatic metastases, the authors outline that surgery and local treatment are applicable for 20 per cent of patients. But some of these local treatments may have contra-indications or may entail complications. Radiotherapy techniques used to have possible severe late effects on the liver, but new external radiotherapy apparatus, like the Cyberknife, can now be used. With its ballistic technique and its tracking system, it allows healthy tissues to be protected. It is also well tolerated by the patients. A comparative study with other local treatment techniques (radio-frequency, alcoolization, chemoembolisation) is still to be done. Short communication

  9. In vivo dose measurement using TLDs and MOSFET dosimeters for cardiac radiosurgery.

    Science.gov (United States)

    Gardner, Edward A; Sumanaweera, Thilaka S; Blanck, Oliver; Iwamura, Alyson K; Steel, James P; Dieterich, Sonja; Maguire, Patrick

    2012-05-10

    In vivo measurements were made of the dose delivered to animal models in an effort to develop a method for treating cardiac arrhythmia using radiation. This treatment would replace RF energy (currently used to create cardiac scar) with ionizing radiation. In the current study, the pulmonary vein ostia of animal models were irradiated with 6 MV X-rays in order to produce a scar that would block aberrant signals characteristic of atrial fibrillation. The CyberKnife radiosurgery system was used to deliver planned treatments of 20-35 Gy in a single fraction to four animals. The Synchrony system was used to track respiratory motion of the heart, while the contractile motion of the heart was untracked. The dose was measured on the epicardial surface near the right pulmonary vein and on the esophagus using surgically implanted TLD dosimeters, or in the coronary sinus using a MOSFET dosimeter placed using a catheter. The doses measured on the epicardium with TLDs averaged 5% less than predicted for those locations, while doses measured in the coronary sinus with the MOSFET sensor nearest the target averaged 6% less than the predicted dose. The measurements on the esophagus averaged 25% less than predicted. These results provide an indication of the accuracy with which the treatment planning methods accounted for the motion of the target, with its respiratory and cardiac components. This is the first report on the accuracy of CyberKnife dose delivery to cardiac targets.

  10. Uncertainties associated with treatments of hepatic lesions in stereotactic body radiation therapy (SBRT) using respiratory tracking

    International Nuclear Information System (INIS)

    Charoy, Marie

    2014-01-01

    Oscar Lambret Center treated with Cyberknife R , since June 2007, liver lesions in stereotactic conditions with respiratory tracking using external LEDs correlated with seeds implanted near the target. Clinical results show excellent local control but there are still uncertainties in the preparation and delivery of treatment. The aims of this thesis are to identify and quantify these uncertainties, to define solutions and/or alternatives and to assess their added value. As a first step, the method of the target definition by the radiation oncologist is evaluated. Improvement of the method currently used in routine is considered, including the choice of the most appropriate imaging and the intervention of a second operator, expert in imaging (radiologist). The organ at risk and target movements induced by the respiratory motion are not taken into account in the treatment planning step, performed on the 3D images (the so-called planning CT). The dosimetric impact associated with this type of planning is evaluated using 4D Monte Carlo simulations that take into account patient and linear accelerator movements and the synchrony between both movements. The question of 4D planning as prospect of improvement is then investigated. Movements and deformations of the liver due to respiration are also implicated in the uncertainties involved in the treatment. The correlation model of external markers with the target, used for respiratory tracking, ignores eventual deformations and rotations within the liver. A study of the impact on the target tracking is performed. All these studies were conducted using real patient data sets. (author) [fr

  11. Treatment planning for MLC based robotic radiosurgery for brain metastases: plan comparison with circular fields and suggestions for planning strategies

    OpenAIRE

    Schmitt Daniela; El Shafie Rami; Klüter Sebastian; Arians Nathalie; Schubert Kai; Rieken Stefan; Debus Jürgen; Paul Angela

    2017-01-01

    To evaluate the possible range of application of the new InCise2 MLC for the CyberKnife M6 system in brain radiosurgery, a plan comparison was made for 10 brain metastases sized between 1.5 and 9cm3 in 10 patients treated in a single fraction each. The target volumes consist of a PTV derived by expanding the GTV by 1mm and were chosen to have diversity in the cohort regarding regularity of shape, location and the structures needed to be blocked for beam transmission in the vicinity. For each ...

  12. Predictive factors for the response of pulmonary tumours treated by robotic stereotactic radiotherapy; Facteurs predictifs pour la reponse des tumeurs pulmonaires traitees par radiotherapie stereotaxique robotisee

    Energy Technology Data Exchange (ETDEWEB)

    Doyen, J.; Benezery, K.; Thariat, J.; Angellier, G.; Poudenx, M.; Bondiau, P.Y. [Centre Antoine-Lacassagne, 06 - Nice (France); Beckendorf, V. [Centre Alexis-Vautrin, 54 - Nancy (France); Venissac, N. [Centre hospitalo-universitaire Pasteur, 06 - Nice (France)

    2010-10-15

    The authors report a study which aimed at identifying factors influencing the response to radiotherapy performed in robotic stereotactic conditions with CyberKnife within the frame of treatment of primitive or secondary pulmonary tumours. Thirty eight stage I cancers, 22 metastases including 17 epidermoid carcinomas, and 43 adenocarcinomas have been treated this way. The analysis of data and results reveals that feminine gender, a biological dose greater than 140 Gy, and an age greater than 65 year old are associated with a better tumour response. Short communication

  13. Accuracy of Robotic Radiosurgical Liver Treatment Throughout the Respiratory Cycle

    International Nuclear Information System (INIS)

    Winter, Jeff D.; Wong, Raimond; Swaminath, Anand; Chow, Tom

    2015-01-01

    in Cyberknife liver treatment and, unlike prediction errors, are not strongly correlated with target motion amplitude. Aggregate 3-dimensional radial position errors presented here suggest the target will be within 4 mm of the target volume for 95% of the beam delivery.

  14. Incidence of Changes in Respiration-Induced Tumor Motion and Its Relationship With Respiratory Surrogates During Individual Treatment Fractions

    International Nuclear Information System (INIS)

    Malinowski, Kathleen; McAvoy, Thomas J.; George, Rohini; Dietrich, Sonja; D’Souza, Warren D.

    2012-01-01

    Purpose: To determine how frequently (1) tumor motion and (2) the spatial relationship between tumor and respiratory surrogate markers change during a treatment fraction in lung and pancreas cancer patients. Methods and Materials: A Cyberknife Synchrony system radiographically localized the tumor and simultaneously tracked three respiratory surrogate markers fixed to a form-fitting vest. Data in 55 lung and 29 pancreas fractions were divided into successive 10-min blocks. Mean tumor positions and tumor position distributions were compared across 10-min blocks of data. Treatment margins were calculated from both 10 and 30 min of data. Partial least squares (PLS) regression models of tumor positions as a function of external surrogate marker positions were created from the first 10 min of data in each fraction; the incidence of significant PLS model degradation was used to assess changes in the spatial relationship between tumors and surrogate markers. Results: The absolute change in mean tumor position from first to third 10-min blocks was >5 mm in 13% and 7% of lung and pancreas cases, respectively. Superior–inferior and medial–lateral differences in mean tumor position were significantly associated with the lobe of lung. In 61% and 54% of lung and pancreas fractions, respectively, margins calculated from 30 min of data were larger than margins calculated from 10 min of data. The change in treatment margin magnitude for superior–inferior motion was >1 mm in 42% of lung and 45% of pancreas fractions. Significantly increasing tumor position prediction model error (mean ± standard deviation rates of change of 1.6 ± 2.5 mm per 10 min) over 30 min indicated tumor–surrogate relationship changes in 63% of fractions. Conclusions: Both tumor motion and the relationship between tumor and respiratory surrogate displacements change in most treatment fractions for patient in-room time of 30 min.

  15. Incidence of Changes in Respiration-Induced Tumor Motion and Its Relationship With Respiratory Surrogates During Individual Treatment Fractions

    Energy Technology Data Exchange (ETDEWEB)

    Malinowski, Kathleen [Department of Bioengineering, A. James Clark School of Engineering, University of Maryland, College Park, MD (United States); Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD (United States); McAvoy, Thomas J. [Department of Bioengineering, A. James Clark School of Engineering, University of Maryland, College Park, MD (United States); Institute of Systems Research, University of Maryland, College Park, MD (United States); George, Rohini [Department of Bioengineering, A. James Clark School of Engineering, University of Maryland, College Park, MD (United States); Dietrich, Sonja [Department of Radiation Oncology, Stanford University School of Medicine, Palo Alto, CA (United States); D' Souza, Warren D., E-mail: wdsou001@umaryland.edu [Department of Bioengineering, A. James Clark School of Engineering, University of Maryland, College Park, MD (United States); Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD (United States)

    2012-04-01

    Purpose: To determine how frequently (1) tumor motion and (2) the spatial relationship between tumor and respiratory surrogate markers change during a treatment fraction in lung and pancreas cancer patients. Methods and Materials: A Cyberknife Synchrony system radiographically localized the tumor and simultaneously tracked three respiratory surrogate markers fixed to a form-fitting vest. Data in 55 lung and 29 pancreas fractions were divided into successive 10-min blocks. Mean tumor positions and tumor position distributions were compared across 10-min blocks of data. Treatment margins were calculated from both 10 and 30 min of data. Partial least squares (PLS) regression models of tumor positions as a function of external surrogate marker positions were created from the first 10 min of data in each fraction; the incidence of significant PLS model degradation was used to assess changes in the spatial relationship between tumors and surrogate markers. Results: The absolute change in mean tumor position from first to third 10-min blocks was >5 mm in 13% and 7% of lung and pancreas cases, respectively. Superior-inferior and medial-lateral differences in mean tumor position were significantly associated with the lobe of lung. In 61% and 54% of lung and pancreas fractions, respectively, margins calculated from 30 min of data were larger than margins calculated from 10 min of data. The change in treatment margin magnitude for superior-inferior motion was >1 mm in 42% of lung and 45% of pancreas fractions. Significantly increasing tumor position prediction model error (mean {+-} standard deviation rates of change of 1.6 {+-} 2.5 mm per 10 min) over 30 min indicated tumor-surrogate relationship changes in 63% of fractions. Conclusions: Both tumor motion and the relationship between tumor and respiratory surrogate displacements change in most treatment fractions for patient in-room time of 30 min.

  16. Definitive Treatment of Early-Stage Non-Small Cell Lung Cancer with Stereotactic Ablative Body Radiotherapy in a Community Cancer Center Setting

    Directory of Open Access Journals (Sweden)

    Cory eHeal

    2015-06-01

    Full Text Available IntroductionSABR provides a superior NSCLC treatment option when compared to conventional radiotherapy for patients deemed inoperable or refusing surgery. This study retrospectively analyzed the rates of tumor control and toxicity following SABR treatment (Cyberknife system of primary early-stage NSCLC in a community setting.MethodsOne hundred patients were treated between 2007 and 2011. Patients with T3-4 or N1-3 disease, metastasis, recurrent local disease, or a non-lung primary were excluded from analysis. All patients had biopsy proven disease. Staging included CT or FDGPET scan. Median dose was 54Gy (45-60; 18Gy (10-20 per fraction. Median PTV expansion was 8mm (2-10. Median BED was 151.2. Tumors were tracked via Synchrony, X-Sight Lung, or X-Sight Spine. Patients were evaluated for local control, overall survival, and toxicity. All local failures were determined by evaluating post treatment PET/CT.ResultsWith a median follow up of 27.5 months, the 1-, 2-, and 3-year local control rates were 100%, 93.55%, and 84.33%, respectively. Median survival was 2.29 years; actuarial 3- year survival was 37.20%. Grade-3 toxicity was observed in 2% of patients (pneumonia within two months of treatment, n=1; chronic pneumonitis requiring hospital admission, n=1. No patients demonstrated toxicity above Grade-3. Multivariate analysis did not show T-stage as an independent predictor of OS, though it did trend toward significance.ConclusionIn a community-center setting, definitive treatment of NSCLC with SABR for nonsurgical candidates and those who choose to forego surgery result in excellent and comparable rates of local control and toxicity compared to published series from large academic centers.

  17. WE-B-19A-01: SRT II: Uncertainties in SRT

    International Nuclear Information System (INIS)

    Dieterich, S; Schlesinger, D; Geneser, S

    2014-01-01

    SRS delivery has undergone major technical changes in the last decade, transitioning from predominantly frame-based treatment delivery to imageguided, frameless SRS. It is important for medical physicists working in SRS to understand the magnitude and sources of uncertainty involved in delivering SRS treatments for a multitude of technologies (Gamma Knife, CyberKnife, linac-based SRS and protons). Sources of SRS planning and delivery uncertainty include dose calculation, dose fusion, and intra- and inter-fraction motion. Dose calculations for small fields are particularly difficult because of the lack of electronic equilibrium and greater effect of inhomogeneities within and near the PTV. Going frameless introduces greater setup uncertainties that allows for potentially increased intra- and interfraction motion, The increased use of multiple imaging modalities to determine the tumor volume, necessitates (deformable) image and contour fusion, and the resulting uncertainties introduced in the image registration process further contribute to overall treatment planning uncertainties. Each of these uncertainties must be quantified and their impact on treatment delivery accuracy understood. If necessary, the uncertainties may then be accounted for during treatment planning either through techniques to make the uncertainty explicit, or by the appropriate addition of PTV margins. Further complicating matters, the statistics of 1-5 fraction SRS treatments differ from traditional margin recipes relying on Poisson statistics. In this session, we will discuss uncertainties introduced during each step of the SRS treatment planning and delivery process and present margin recipes to appropriately account for such uncertainties. Learning Objectives: To understand the major contributors to the total delivery uncertainty in SRS for Gamma Knife, CyberKnife, and linac-based SRS. Learn the various uncertainties introduced by image fusion, deformable image registration, and contouring

  18. Participating in an International Stereotactic Radiotherapy Patient Registry: The Establishment of Data Collection Pathways.

    Science.gov (United States)

    Yahya, Aylin; Arneric, Eva; Kernutt, Elizabeth; Baldacchino, Fiona; Haworth, Claire; Kedda, Mary-Anne; Tang, Colin; Bydder, Sean; Corica, Tammy

    2017-06-29

    Aim To describe data collection pathways and practical challenges experienced by an academic comprehensive cancer centre aiming to record clinical data for patients being treated with a novel radiotherapy treatment modality. Methods Various options to capture data from all patients treated with the CyberKnife Robotic Radiosurgery System at Sir Charles Gairdner Hospital (SCGH) in Western Australia were explored. An international multicenter web-based secure database established and maintained by the Radiosurgery Society the RSSearch® Patient Registry was selected. Data were collected and entered over four contiguous phases, with either opt-in or opt-out consent and the completion of Patient Reported Outcome questionnaires for specific sub-groups. Results Between April 2014 and June 2016, 461 patients at Sir Charles Gairdner Hospital were enrolled in the RSSearch® Patient Registry with the collection of over 17,500 data items. From 461 patients enrolled, 447 patients were treated with the CyberKnife Robotic Radiosurgery System. The majority of patients were treated for either a malignant primary (43.2%) or metastatic disease (39.4%). The establishment of matrix organisational processes for data collection led to the development of improved workflow patterns and data collection pathways. Conclusions This article describes the processes developed by a single centre to establish an efficient system for data collection and participation in an international registry. The opt-out approach was more efficient in terms of patient recruitment compared to the informed-consent method used in earlier phases. The experience of this single centre may help inform other institutions considering data collection options for assessments of new or novel treatments.

  19. SU-F-T-649: Dosimetric Evaluation of Non-Coplanar Arc Therapy Using a Novel Rotating Gamma Ray System

    Energy Technology Data Exchange (ETDEWEB)

    Eldib, A; Chibani, O; Jin, L; Fan, J; Veltchev, I; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States); Mora, G [Universidade de Lisboa, Codex, Lisboa (Portugal); Li, J [Cyber Medical Inc, Xian, Shaanxi (China)

    2016-06-15

    Purpose: Stereotactic intra and extra-cranial body radiation therapy has evolved with advances in treatment accuracy, effective radiation dose, and parameters necessary to maximize machine capabilities. Novel gamma systems with a ring type gantry were developed having the ability to perform oblique arcs. The aim of this study is to explore the dosimetric advantages of this new system. Methods: The rotating Gamma system is named CybeRay (Cyber Medical Corp., Xian, China). It has a treatment head of 16 cobalt-60 sources focused to the isocenter, which can rotate 360° on the ring gantry and swing 35° in the superior direction. Treatment plans were generated utilizing our in-house Monte Carlo treatment planning system. A cylindrical phantom was modeled with 2mm voxel size. Dose inside the cylindrical phantom was calculated for coplanar and non-coplanar arcs. Dosimetric differences between CybeRay cobalt beams and CyberKnife 6MV beams were compared in a lung phantom and for previously treated SBRT patients. Results: The full width at half maxima of cross profiles in the S-I direction for the coplanar setup matched the cone sizes, while for the non-coplanar setup, FWHM was larger by 2mm for a 10mm cone and about 5mm for larger cones. In the coronal and sagittal view, coplanar beams showed elliptical shaped isodose lines, while non-coplanar beams showed circular isodose lines. Thus proper selection of the oblique angle and cone size can aid optimal dose matching to the target volume. Comparing a single 5mm cone from CybeRay to that from CyberKnife showed similar penumbra in a lung phantom but CybeRay had significant lower doses beyond lung tissues. Comparable treatment plans were obtained with CybeRay as that from CyberKnife.ConclusionThe noncoplanar multiple source arrangement of CybeRay will be of great clinical benefits for stereotactic intra and extra-cranial radiation therapy.

  20. Prostate-specific antigen bounce following stereotactic body radiation therapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Charles C. Vu

    2014-01-01

    Full Text Available Introduction: Prostate-specific antigen (PSA bounce after brachytherapy has been well-documented. This phenomenon has also been identified in patients undergoing stereotactic body radiation therapy (SBRT. While the parameters that predict PSA bounce have been extensively studied in prostate brachytherapy patients, this study is the first to analyze the clinical and pathologic predictors of PSA bounce in prostate SBRT patients. Materials and Methods: Our institution has maintained a prospective database of patients undergoing SBRT for prostate cancer since 2006. Our study population includes patients between May 2006 and November 2011 who have at least 18 months of follow-up. All patients were treated using the CyberKnife treatment system. The prescription dose was 3500-3625cGy in 5 fractions.Results: 120 patients were included in our study. Median PSA follow-up was 24 months (range 18-78 months. 34 (28% patients had a PSA bounce. The median time to PSA bounce was 9 months, and the median bounce size was 0.50ng/mL. On univariate analysis, only younger age (p = .011 was shown to be associated with an increased incidence of PSA bounce. Other patient factors, including race, prostate size, prior treatment by hormones, and family history of prostate cancer, did not predict PSA bounces. None of the tumor characteristics studied, including Gleason score, pre-treatment PSA, T-stage, or risk classification by NCCN guidelines, was associated with increased incidence of PSA bounces. Younger age was the only statistically significant predictor of PSA bounce on multivariate analysis (OR = 0.937, p = 0.009.Conclusion: PSA bounce, which has been reported after prostate brachytherapy, is also seen in a significant percentage of patients after CyberKnife SBRT. Close observation rather than biopsy can be considered for these patients. Younger age was the only factor that predicted PSA bounce.

  1. SU-E-T-409: Intensity Modulated Robotic Radiotherapy

    International Nuclear Information System (INIS)

    Wang, B; Jin, L; Li, J; Chen, L; Ma, C; Fan, J; Zhang, C

    2014-01-01

    Purpose: As compared with the IRIS-based models, the MLC-based CyberKnife system allows more efficient treatment delivery due to its improved coverage of large lesions and intensity modulation. The treatment delivery efficiency is mainly determined by the number of selected nodes. This study aimed to demonstrate that relatively small sets of optimally selected nodes could produce high-quality plans. Methods: The full body path of the CyberKnife system consists of 110 nodes, from which we selected various sets for 4 prostate cancer cases using our in-house beamselection software. With the selected nodes we generated IMRT plans using our in-house beamlet-based inverse-planning optimization program. We also produced IMRT plans using the MultiPlan treatment planning system (version 5.0) for the same cases. Furthermore, the nodes selected by MultiPlan were used to produce plans with our own optimization software so that we could compare the quality of the selected sets of nodes. Results: Our beam-selection program selected one node-set for each case, with the number of nodes ranging from 23 to 34. The IMRT plans based on the selected nodes and our in-house optimization program showed adequate target coverage, with favorable critical structure sparing for the cases investigated. Compared with the plans using the nodes selected by MultiPlan, the plans generated with our selected beams provided superior rectum/bladder sparing for 75% of the cases. The plans produced by MultiPlan with various numbers of nodes also suggested that the plan quality was not compromised significantly when the number of nodes was reduced. Conclusion: Our preliminary results showed that with beamletbased planning optimization, one could produce high-quality plans with an optimal set of nodes for MLC-based robotic radiotherapy. Furthermore, our beam-selection strategy could help further improve critical structure sparing

  2. SU-E-T-88: Acceptance Testing and Commissioning Measurements of a Newly Released InCiseâ„¢ Multileaf Collimator for CyberKnife M6â„¢ System

    Energy Technology Data Exchange (ETDEWEB)

    Huq, M Saiful; Ozhasoglu, C; Jang, S; Hwang, M; Heron, D; Lalonde, R [UPMC CancerCenter, Pittsburgh, PA (United States)

    2015-06-15

    Purpose: Accuray recently released a new collimator, the InCise™ Multileaf Collimator (MLC), for clinical use with the CyberKnife M6™ System. This work reports the results of acceptance testing and commissioning measurements for this collimator. Methods: The MLC consists of 41 pairs of 2.5 mm wide leaves projecting a clinical maximum field size of 110 mm x 97.5 mm at 800 mm SAD. The leaves are made of tungsten, 90 mm in height and tilted by 0.5 degree. The manufacturer stated leaf positioning accuracy and reproducibility are 0.5 mm and 0.4 mm respectively at 800 mm SAD. The leaf over-travel is 100% with full interdigitation capability. Acceptance testing included, but are not limited to, the verification of the specifications of various parameters described above, leakage measurements and end-to-end tests. Dosimetric measurements included, but not limited to, measurements of output factors, open beam profiles, tissue-phantom ratios, beam flatness and symmetry, and patient specific QA. Results: All measurements were well within the manufacturer specifications. The values of output factors ranged from 0.804 (smallest field size of 7.6 mm x 7.5 mm) to 1.018 (largest field size of 110.0 mm x 97.5 mm). End-to-end test results for the various tracking modes are: Skull (0.27mm), fiducial (0.16mm), Xsight Spine (0.4mm), Xsight Lung (0.93 mm) and Synchrony (0.43mm). Measured maximum and average leakage was 0.37% and 0.3%, respectively. Patient-specific QA measurements with chamber were all within 5% absolute dose agreement, and film measurements all passed 2%/2mm gamma evaluation for more than 95% of measurement points. Conclusion: The presented results are the first set of data reported on the InCise™ MLC. The MLC proved to be very reliable and is currently in clinical use.

  3. Cyberknife Stereotactic Body Radiation Therapy for Nonresectable Tumors of the Liver: Preliminary Results

    Directory of Open Access Journals (Sweden)

    K. Goyal

    2010-01-01

    Full Text Available Purpose. Stereotactic body radiation therapy (SBRT has emerged as a treatment option for local tumor control of primary and secondary malignancies of the liver. We report on our updated experience with SBRT in patients with non-resectable tumors of the liver. Methods. Our first 17 consecutive patients (mean age 58.1 years receiving SBRT for HCC (=6, IHC (=3, and LM (=8 are presented. Mean radiation dose was 34Gy delivered over 1–3 fractions. Results. Treated patients had a mean decrease in maximum pretreatment tumor diameter from 6.9±4.6 cm to 5.0±2.1 cm at three months after treatment (<.05. The mean total tumor volume reduction was 44% at six months (<.05. 82% of all patients (14/17 achieved local control with a median follow-up of 8 months. 100% of patients with HCC (=6 achieved local control. Patients with surgically placed fiducial markers had no complications related to marker placement. Conclusion. Our preliminary results showed that SBRT is a safe and effective local treatment modality in selected patients with liver malignancies with minimal adverse events. Further studies are needed to define its role in the management of these malignancies.

  4. Intrafraction Prostate Translations and Rotations During Hypofractionated Robotic Radiation Surgery: Dosimetric Impact of Correction Strategies and Margins

    Energy Technology Data Exchange (ETDEWEB)

    Water, Steven van de, E-mail: s.vandewater@erasmusmc.nl [Erasmus MC Cancer Institute, Department of Radiation Oncology, Rotterdam (Netherlands); Valli, Lorella [Erasmus MC Cancer Institute, Department of Radiation Oncology, Rotterdam (Netherlands); Alma Mater Studiorum, Department of Physics and Astronomy, Bologna University, Bologna (Italy); Aluwini, Shafak [Erasmus MC Cancer Institute, Department of Radiation Oncology, Rotterdam (Netherlands); Lanconelli, Nico [Alma Mater Studiorum, Department of Physics and Astronomy, Bologna University, Bologna (Italy); Heijmen, Ben; Hoogeman, Mischa [Erasmus MC Cancer Institute, Department of Radiation Oncology, Rotterdam (Netherlands)

    2014-04-01

    Purpose: To investigate the dosimetric impact of intrafraction prostate motion and the effect of robot correction strategies for hypofractionated CyberKnife treatments with a simultaneously integrated boost. Methods and Materials: A total of 548 real-time prostate motion tracks from 17 patients were available for dosimetric simulations of CyberKnife treatments, in which various correction strategies were included. Fixed time intervals between imaging/correction (15, 60, 180, and 360 seconds) were simulated, as well as adaptive timing (ie, the time interval reduced from 60 to 15 seconds in case prostate motion exceeded 3 mm or 2° in consecutive images). The simulated extent of robot corrections was also varied: no corrections, translational corrections only, and translational corrections combined with rotational corrections up to 5°, 10°, and perfect rotational correction. The correction strategies were evaluated for treatment plans with a 0-mm or 3-mm margin around the clinical target volume (CTV). We recorded CTV coverage (V{sub 100%}) and dose-volume parameters of the peripheral zone (boost), rectum, bladder, and urethra. Results: Planned dose parameters were increasingly preserved with larger extents of robot corrections. A time interval between corrections of 60 to 180 seconds provided optimal preservation of CTV coverage. To achieve 98% CTV coverage in 98% of the treatments, translational and rotational corrections up to 10° were required for the 0-mm margin plans, whereas translational and rotational corrections up to 5° were required for the 3-mm margin plans. Rectum and bladder were spared considerably better in the 0-mm margin plans. Adaptive timing did not improve delivered dose. Conclusions: Intrafraction prostate motion substantially affected the delivered dose but was compensated for effectively by robot corrections using a time interval of 60 to 180 seconds. A 0-mm margin required larger extents of additional rotational corrections than a 3

  5. Intrafraction Prostate Translations and Rotations During Hypofractionated Robotic Radiation Surgery: Dosimetric Impact of Correction Strategies and Margins

    International Nuclear Information System (INIS)

    Water, Steven van de; Valli, Lorella; Aluwini, Shafak; Lanconelli, Nico; Heijmen, Ben; Hoogeman, Mischa

    2014-01-01

    Purpose: To investigate the dosimetric impact of intrafraction prostate motion and the effect of robot correction strategies for hypofractionated CyberKnife treatments with a simultaneously integrated boost. Methods and Materials: A total of 548 real-time prostate motion tracks from 17 patients were available for dosimetric simulations of CyberKnife treatments, in which various correction strategies were included. Fixed time intervals between imaging/correction (15, 60, 180, and 360 seconds) were simulated, as well as adaptive timing (ie, the time interval reduced from 60 to 15 seconds in case prostate motion exceeded 3 mm or 2° in consecutive images). The simulated extent of robot corrections was also varied: no corrections, translational corrections only, and translational corrections combined with rotational corrections up to 5°, 10°, and perfect rotational correction. The correction strategies were evaluated for treatment plans with a 0-mm or 3-mm margin around the clinical target volume (CTV). We recorded CTV coverage (V 100% ) and dose-volume parameters of the peripheral zone (boost), rectum, bladder, and urethra. Results: Planned dose parameters were increasingly preserved with larger extents of robot corrections. A time interval between corrections of 60 to 180 seconds provided optimal preservation of CTV coverage. To achieve 98% CTV coverage in 98% of the treatments, translational and rotational corrections up to 10° were required for the 0-mm margin plans, whereas translational and rotational corrections up to 5° were required for the 3-mm margin plans. Rectum and bladder were spared considerably better in the 0-mm margin plans. Adaptive timing did not improve delivered dose. Conclusions: Intrafraction prostate motion substantially affected the delivered dose but was compensated for effectively by robot corrections using a time interval of 60 to 180 seconds. A 0-mm margin required larger extents of additional rotational corrections than a 3-mm

  6. Photons, protons or carbon ions for stage I non-small cell lung cancer - Results of the multicentric ROCOCO in silico study.

    Science.gov (United States)

    Wink, Krista C J; Roelofs, Erik; Simone, Charles B; Dechambre, David; Santiago, Alina; van der Stoep, Judith; Dries, Wim; Smits, Julia; Avery, Stephen; Ammazzalorso, Filippo; Jansen, Nicolas; Jelen, Urszula; Solberg, Timothy; de Ruysscher, Dirk; Troost, Esther G C

    2018-03-12

    To compare dose to organs at risk (OARs) and dose-escalation possibility for 24 stage I non-small cell lung cancer (NSCLC) patients in a ROCOCO (Radiation Oncology Collaborative Comparison) trial. For each patient, 3 photon plans [Intensity-modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT) and CyberKnife], a double scattered proton (DSP) and an intensity-modulated carbon-ion (IMIT) therapy plan were created. Dose prescription was 60 Gy (equivalent) in 8 fractions. The mean dose and dose to 2% of the clinical target volume (CTV) were lower for protons and ions compared with IMRT (p < 0.01). Doses to the lungs, heart, and mediastinal structures were lowest with IMIT (p < 0.01), doses to the spinal cord were lowest with DSP (p < 0.01). VMAT and CyberKnife allowed for reduced doses to most OARs compared with IMRT. Dose escalation was possible for 8 patients. Generally, the mediastinum was the primary dose-limiting organ. On average, the doses to the OARs were lowest using particles, with more homogenous CTV doses. Given the ability of VMAT and CyberKnife to limit doses to OARs compared with IMRT, the additional benefit of particles may only be clinically relevant in selected patients and thus should be carefully weighed for every individual patient. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Hypofractionated stereotactic body radiation therapy for elderly patients with stage IIB–IV nonsmall cell lung cancer who are ineligible for or refuse other treatment modalities

    Directory of Open Access Journals (Sweden)

    Karam SD

    2014-10-01

    sample size and the heterogeneity of the patient population, larger studies are needed before adopting this treatment option into clinical practice. Keywords: stereotactic body radiation therapy, CyberKnife, stage IIB, stage IIIA, stage IV, nodal, chemotherapy

  8. WE-DE-BRA-11: A Study of Motion Tracking Accuracy of Robotic Radiosurgery Using a Novel CCD Camera Based End-To-End Test System

    Energy Technology Data Exchange (ETDEWEB)

    Wang, L; M Yang, Y [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); Nelson, B [Logos Systems Intl, Scotts Valley, CA (United States)

    2016-06-15

    Purpose: A novel end-to-end test system using a CCD camera and a scintillator based phantom (XRV-124, Logos Systems Int’l) capable of measuring the beam-by-beam delivery accuracy of Robotic Radiosurgery (CyberKnife) was developed and reported in our previous work. This work investigates its application in assessing the motion tracking (Synchrony) accuracy for CyberKnife. Methods: A QA plan with Anterior and Lateral beams (with 4 different collimator sizes) was created (Multiplan v5.3) for the XRV-124 phantom. The phantom was placed on a motion platform (superior and inferior movement), and the plans were delivered on the CyberKnife M6 system using four motion patterns: static, Sine- wave, Sine with 15° phase shift, and a patient breathing pattern composed of 2cm maximum motion with 4 second breathing cycle. Under integral recording mode, the time-averaged beam vectors (X, Y, Z) were measured by the phantom and compared with static delivery. In dynamic recording mode, the beam spots were recorded at a rate of 10 frames/second. The beam vector deviation from average position was evaluated against the various breathing patterns. Results: The average beam position of the six deliveries with no motion and three deliveries with Synchrony tracking on ideal motion (sinewave without phase shift) all agree within −0.03±0.00 mm, 0.10±0.04, and 0.04±0.03 in the X, Y, and X directions. Radiation beam width (FWHM) variations are within ±0.03 mm. Dynamic video record showed submillimeter tracking stability for both regular and irregular breathing pattern; however the tracking error up to 3.5 mm was observed when a 15 degree phase shift was introduced. Conclusion: The XRV-124 system is able to provide 3D and 4D targeting accuracy for CyberKnife delivery with Synchrony. The experimental results showed sub-millimeter delivery in phantom with excellent correlation in target to breathing motion. The accuracy was degraded when irregular motion and phase shift was introduced.

  9. Prostate Clinical Outlook Visualization System for Patients and Clinicians Considering Cyberknife Treatment—A Personalized Approach

    Directory of Open Access Journals (Sweden)

    Jihwan Park

    2018-03-01

    Full Text Available Background: When a patient presents with localized prostate cancer, referral for radiation oncology consultation includes a discussion of likely outcomes of therapy. Among current radiation treatments for prostate cancers, hypo-fractionated stereotactic body radiation therapy (SBRT has gained clinical acceptance based on efficacy, short duration of treatment, and the potential radiobiological advantages. The Prostate Clinical Outlook Visualization System (PCOVS was developed to provide the patient and the clinician with a tool to visualize probable treatment outcomes using institutional, patient specific data for comparing results of treatment. Methods: We calculated the prostate cancer outcomes—for each prospective patient using the EPIC-26 quality of life parameters based on clinical outcomes data of 580 prostate cancer patients who were treated with SBRT. We applied Kaplan-Meier analysis using the ASTRO definition for biochemical recurrence (BCR free survival and likely outcome and the PCOVS nomogram to calculate parameters for quality of life. Open-source R, RShiny, and MySQL were used to develop a modularized architecture system. Results: The PCOVS presents patient specific risk scores in a gauge chart style and risk free probability bar plots to compare the treatment data of patients treated with SBRT. The PCOVS generates reports, in PDF, which consists of a comparison charts of risk free probabilities late effects and gauge charts of risk scores. This system is now being expanded as a web-based service to patients. Conclusions: The PCOVS visualized patient specific likely outcomes were compared to treatment data from a single department, helping the patient and the clinician to visualize likely outcomes. The PCOVS approach can be expanded to other specialties of oncology with the flexible, modularized architecture, which can be customized by changing independent modules.

  10. Treatment Techniques and Site Considerations Regarding Dysphagia-Related Quality of Life in Cancer of the Oropharynx and Nasopharynx

    International Nuclear Information System (INIS)

    Teguh, David N.; Levendag, Peter C.; Noever, Inge; Rooij, Peter van; Voet, Peter; Est, Henrie van der; Sipkema, Dick; Sewnaik, Aniel; Baatenburg de Jong, Robert Jan; Bije, Daniel de la; Schmitz, Paul

    2008-01-01

    Purpose: To assess the relationship for oropharyngeal (OP) cancer and nasopharyngeal (NP) cancer between the dose received by the swallowing structures and the dysphagia related quality of life (QoL). Methods and Materials: Between 2000 and 2005, 85 OP and 47 NP cancer patients were treated by radiation therapy. After 46 Gy, OP cancer is boosted by intensity-modulated radiation therapy (IMRT), brachytherapy (BT), or frameless stereotactic radiation/cyberknife (CBK). After 46 Gy, the NP cancer was boosted with parallel-opposed fields or IMRT to a total dose of 70 Gy; subsequently, a second boost was given by either BT (11 Gy) or stereotactic radiation (SRT)/CBK (11.2 Gy). Sixty OP and 21 NP cancer patients responded to functional and QoL questionnaires (i.e., the Performance Status Scales, European Organization for Research and Treatment of Cancer H and N35, and M.D. Anderson Dysphagia Inventory). The swallowing muscles were delineated and the mean dose calculated using the original three-dimensional computed tomography-based treatment plans. Univariate analyses were performed using logistic regression analysis. Results: Most dysphagia problems were observed in the base of tongue tumors. For OP cancer, boosting with IMRT resulted in more dysphagia as opposed to BT or SRT/CBK. For NPC patients, in contrast to the first booster dose (46-70 Gy), no additional increase of dysphagia by the second boost was observed. Conclusions: The lowest mean doses of radiation to the swallowing muscles were achieved when using BT as opposed to SRT/CBK or IMRT. For the 81 patients alive with no evidence of disease for at least 1 year, a dose-effect relationship was observed between the dose in the superior constrictor muscle and the 'normalcy of diet' (Performance Status Scales) or 'swallowing scale' (H and N35) scores (p < 0.01)

  11. About the case of a bronchi carcinoma tumor treated by Cyberknife

    International Nuclear Information System (INIS)

    Delourme, J.; Prevost, B.; Lacornerie, T.; Dansin, E.; Lartigau, E.

    2009-01-01

    The carcinoid tumors represent less than 2% of bronchi cancers. The best treatment of resectable tumors is surgery. The chemotherapy is inefficient. the part of radiotherapy is currently controverted, these tumors being generally considered as little radiosensitive with classical techniques. We report the case of a sixty three years patients treated by stereotactic irradiation for a recurrence of a carcinoid bronchi tumor. As conclusion: the typical or atypical character of the tumor is important to consider. The atypical carcinoid tumors have a reserved prognosis because of the frequent existence of ganglions metastases and a recurrence rate higher than the typical carcinoid tumors. The stereotactic and hypo fractionated radiotherapy can constitute an interesting therapy option in case of unresectable tumor or incomplete surgical resection, because of an increased equivalent biological dose. (N.C.)

  12. Hematological Toxicity After Robotic Stereotactic Body Radiosurgery for Treatment of Metastatic Gynecologic Malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Kunos, Charles A., E-mail: charles.kunos@UHhospitals.org [Department of Radiation Oncology, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio (United States); Debernardo, Robert [Department of Obstetrics and Gynecology, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio (United States); Radivoyevitch, Tomas [Department of Epidemiology and Biostatistics, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio (United States); Fabien, Jeffrey; Dobbins, Donald C.; Zhang Yuxia; Brindle, James [Department of Radiation Oncology, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio (United States)

    2012-09-01

    Purpose: To evaluate hematological toxicity after robotic stereotactic body radiosurgery (SBRT) for treatment of women with metastatic abdominopelvic gynecologic malignancies. Methods and Materials: A total of 61 women with stage IV gynecologic malignancies treated with abdominopelvic SBRT were analyzed after ablative radiation (2400 cGy/3 divided consecutive daily doses) delivered by a robotic-armed Cyberknife SBRT system. Abdominopelvic bone marrow was identified using computed tomography-guided contouring. Fatigue and hematologic toxicities were graded by retrospective assignment of common toxicity criteria for adverse events (version 4.0). Bone marrow volume receiving 1000 cGy (V10) was tested for association with post-therapy (median 32 days [25%-75% quartile, 28-45 days]) white- or red-cell counts, hemoglobin levels, and platelet counts as marrow toxicity surrogates. Results: In all, 61 women undergoing abdominopelvic SBRT had a median bone marrow V10 of 2% (25%-75% quartile: 0%-8%). Fifty-seven (93%) of 61 women had received at least 1 pre-SBRT marrow-taxing chemotherapy regimen for metastatic disease. Bone marrow V10 did not associate with hematological adverse events. In all, 15 grade 2 (25%) and 2 grade 3 (3%) fatigue symptoms were self-reported among the 61 women within the first 10 days post-therapy, with fatigue resolved spontaneously in all 17 women by 30 days post-therapy. Neutropenia was not observed. Three (5%) women had a grade 1 drop in hemoglobin level to <10.0 g/dL. Single grade 1, 2, and 3 thrombocytopenias were documented in 3 women. Conclusions: Abdominopelvic SBRT provided ablative radiation dose to cancer targets without increased bone marrow toxicity. Abdominopelvic SBRT for metastatic gynecologic malignancies warrants further study.

  13. Hematological Toxicity After Robotic Stereotactic Body Radiosurgery for Treatment of Metastatic Gynecologic Malignancies

    International Nuclear Information System (INIS)

    Kunos, Charles A.; Debernardo, Robert; Radivoyevitch, Tomas; Fabien, Jeffrey; Dobbins, Donald C.; Zhang Yuxia; Brindle, James

    2012-01-01

    Purpose: To evaluate hematological toxicity after robotic stereotactic body radiosurgery (SBRT) for treatment of women with metastatic abdominopelvic gynecologic malignancies. Methods and Materials: A total of 61 women with stage IV gynecologic malignancies treated with abdominopelvic SBRT were analyzed after ablative radiation (2400 cGy/3 divided consecutive daily doses) delivered by a robotic-armed Cyberknife SBRT system. Abdominopelvic bone marrow was identified using computed tomography-guided contouring. Fatigue and hematologic toxicities were graded by retrospective assignment of common toxicity criteria for adverse events (version 4.0). Bone marrow volume receiving 1000 cGy (V10) was tested for association with post-therapy (median 32 days [25%-75% quartile, 28-45 days]) white- or red-cell counts, hemoglobin levels, and platelet counts as marrow toxicity surrogates. Results: In all, 61 women undergoing abdominopelvic SBRT had a median bone marrow V10 of 2% (25%-75% quartile: 0%-8%). Fifty-seven (93%) of 61 women had received at least 1 pre-SBRT marrow-taxing chemotherapy regimen for metastatic disease. Bone marrow V10 did not associate with hematological adverse events. In all, 15 grade 2 (25%) and 2 grade 3 (3%) fatigue symptoms were self-reported among the 61 women within the first 10 days post-therapy, with fatigue resolved spontaneously in all 17 women by 30 days post-therapy. Neutropenia was not observed. Three (5%) women had a grade 1 drop in hemoglobin level to <10.0 g/dL. Single grade 1, 2, and 3 thrombocytopenias were documented in 3 women. Conclusions: Abdominopelvic SBRT provided ablative radiation dose to cancer targets without increased bone marrow toxicity. Abdominopelvic SBRT for metastatic gynecologic malignancies warrants further study.

  14. SU-G-TeP2-12: IROCHouston and MDAPL SRS Anthropomorphic Phantom Results

    International Nuclear Information System (INIS)

    Molineu, A; Kry, S; Alvarez, P; Hernandez, N; Nguyen, T; Followill, D

    2016-01-01

    Purpose: To report the results of SRS phantom irradiations Methods: Anthropomorphic SRS head phantoms were sent to institutions participating in NCI sponsored SRS clinical trials and institutions interested in verifying SRS treatment delivery. The phantom shell was purchased from Phantom Laboratory and altered to house dosimetry and imaging inserts. The imaging insert has 1.9 cm diameter spherical target. The dosimetry insert holds two TLD capsules and radiochromic film in the coronal and sagittal planes through the center of the target. Institutions were asked to image, plan and treat the phantom as they would an SRS patient. GammaKnife, CyberKnife and c-arm accelerator institutions were asked to cover the target with 15 Gy, 20 Gy and 25 Gy, respectively. Following these guidelines and typical planning protocols for these three types of machines gives roughly 30 Gy to the center of the target for all units. Submission of the DICOM digital data set was required for analysis. Criteria of 5% for TLD results and 85% of pixels passing 5%/3mm gamma analysis were applied beginning in 2013. Results: The phantom was analyzed 269 times between the beginning of 2013 to present. The pass rate is 81%. Nineteen of the irradiation results failed only the TLD criteria, 19 failed only the film criteria and 12 failed both. Irradiations included 32 CyberKnife 23 GammaKnife, 3 TomoTherapy and 211 c-arm units. Planning systems included Eclipse, Ergo, GammaPlan, Hi-Art, iPlan, Monaco, MultiPlan, Pinnacle, RayStation, XiO and XKnife. Irradiations that were not accompanied with DICOM data were not included in this analysis. Conclusion: The phantom is a valuable end-to-end test used to independently verify the accuracy of SRS treatment delivery. This investigation was supported by IROC grant CA180803 awarded by the NCI.

  15. Integration of Three-Dimensional Rotational Angiography in Radiosurgical Treatment Planning of Cerebral Arteriovenous Malformations

    International Nuclear Information System (INIS)

    Conti, Alfredo; Pontoriero, Antonio; Farago, Giuseppe; Midili, Federica; Siragusa, Carmelo; Granata, Francesca; Pitrone, Antonio; De Renzis, Costantino; Longo, Marcello; Tomasello, Francesco

    2011-01-01

    Purpose: Accuracy in delineating the target volume is a major issue for successful stereotactic radiosurgery for arteriovenous malformations. The aim of the present study was to describe a method to integrate three-dimensional (3D) rotational angiography ( (3DRA)) into CyberKnife treatment planning and to investigate its potential advantages compared with computed tomography angiography (CTA) and magnetic resonance angiography. Methods and Materials: A total of 20 patients with a diagnosis of cerebral arteriovenous malformation were included in the present study. All patients underwent multislice computed tomography and 3D-volumetric CTA, (3DRA), and 3D magnetic resonance angiography. The contouring of the target and critical volumes was done separately using CTA and thereafter directly using (3DRA). The composite, conjoint, and disjoint volumes were measured. Results: The use of CTA or (3DRA) resulted in significant differences in the target and critical volumes. The target volume averaged 3.49 ± 3.01 mL measured using CTA and 3.26 ± 2.93 mL measured using (3DRA), for a difference of 8% (p < .05). The conjoint and disjoint volume analysis showed an 88% volume overlap. The qualitative evaluation showed that the excess volume obtained using CTA was mostly tissue surrounding the nidus and venous structures. The mean contoured venous volume was 0.67 mL measured using CTA and 0.88 mL (range, 0.1-2.7) measured using (3DRA) (p < .05). Conclusions: (3DRA) is a volumetric angiographic study that can be integrated into computer-based treatment planning. Although whether (3DRA) provides superior accuracy has not yet been proved, its high spatial resolution is attractive and offers a superior 3D view. This allows a better 3D understanding of the target volume and distribution of the radiation doses within the volume. Additional technical efforts to improve the temporal resolution and the development of software tools aimed at improving the performance of 3D contouring are

  16. Recent applications of nuclear medicine techniques and results in Vietnam

    International Nuclear Information System (INIS)

    Phan Sy An

    2008-01-01

    The author presented recent applications of nuclear medicine techniques and results in Vietnam. The author concentrated some valuable and helpful studies such as functional tests, myocardial perfusion scintigraphy, bone, thyroid, lung, kidney and gastrointestinal tract scintigraphy for diagnosis. The results of RIA and IRMA concerning with thyroid diseases, cancer, microalbuminuria and TSH in blood spot on paper for screening of congenital hypothyroidism in new born babies were also given. The report also mentioned results of liver cancer and palliative bone metastasis treatments in Vietnam. A new technique using gamma probe in surgery for breast cancer was presented. The author introduced some modern teleradiotherapeutic modalities such as cyberknif, gamma knife, gamma rotating systeme and linac recently installed in Vietnam. (author)

  17. Real-time Cherenkov emission portal imaging during CyberKnife® radiotherapy

    International Nuclear Information System (INIS)

    Roussakis, Yiannis; Mason, Suzannah; Dehghani, Hamid; Zhang, Rongxiao; Heyes, Geoff; Webster, Gareth; Green, Stuart; Pogue, Brian

    2015-01-01

    The feasibility of real-time portal imaging during radiation therapy, through the Cherenkov emission (CE) effect is investigated via a medical linear accelerator (CyberKnife ® ) irradiating a partially-filled water tank with a 60 mm circular beam. A graticule of lead/plywood and a number of tissue equivalent materials were alternatively placed at the beam entrance face while the induced CE at the exit face was imaged using a gated electron-multiplying-intensified-charged-coupled device (emICCD) for both stationary and dynamic scenarios. This was replicated on an Elekta Synergy ® linear accelerator with portal images acquired using the iViewGT ™ system. Profiles across the acquired portal images were analysed to reveal the potential resolution and contrast limits of this novel CE based portal imaging technique and compared against the current standard. The CE resolution study revealed that using the lead/plywood graticule, separations down to 3.4  ±  0.5 mm can be resolved. A 28 mm thick tissue-equivalent rod with electron density of 1.69 relative to water demonstrated a CE contrast of 15% through air and 14% through water sections, as compared to a corresponding contrast of 19% and 12% using the iViewGT ™ system. For dynamic scenarios, video rate imaging with 30 frames per second was achieved. It is demonstrated that CE-based portal imaging is feasible to identify both stationary and dynamic objects within a CyberKnife ® radiotherapy treatment field. (note)

  18. Analysis of the factors affecting the safety of robotic stereotactic body radiation therapy for hepatocellular carcinoma patients

    Directory of Open Access Journals (Sweden)

    Liu XJ

    2017-11-01

    Full Text Available Xiaojie Liu,1,* Yongchun Song,1,* Ping Liang,2 Tingshi Su,2 Huojun Zhang,3 Xianzhi Zhao,3 Zhiyong Yuan,1 Ping Wang1 1Department of Radiotherapy,Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin’s Clinical Research Center for Cancer, Tianjin, 2Cyberknife Center, Ruikang Hospital, Guangxi Traditional Chinese Medical University, Nanning, 3Department of Radiotherapy, Shanghai Changhai Hospital, Second Military Medical University, Shanghai, People’s Republic of China *These authors contributed equally to this work Objective: The objective of this study was to investigate the safety of robotic stereotactic body radiation therapy (SBRT for hepatocellular carcinoma (HCC patients and its related factors.Methods: A total of 74 HCC patients with Child–Turcotte–Pugh (CTP Class A were included in a multi-institutional, single-arm Phase II trial (NCT 02363218 between February 2013 and August 2016. All patients received SBRT treatment at a dose of 45 Gy/3f. The liver function was compared before and after SBRT treatment by the analysis of adverse hepatic reactions and changes in CTP classification.Results: After SBRT treatment, eight patients presented with decreases in CTP classification and 13 patients presented with ≥ grade 2 hepatic adverse reactions. For patients presenting with ≥ grade 2 hepatic adverse reactions, the total liver volume of ≤1,162 mL and a normal liver volume (total liver volume – gross tumor volume [GTV] of ≤1,148 mL were found to be independent risk factors and statistically significant (P<0.05.Conclusion: The total liver volume and normal liver volume are associated with the occurrence of ≥ grade 2 hepatic adverse reactions after SBRT treatment on HCC patients. Therefore, if the fractionated scheme of 45 Gy/3f is applied in SBRT for HCC patients, a total liver volume >1,162 mL and a normal liver

  19. Intracranial stereotactic radiosurgery with an adapted linear accelerator vs. robotic radiosurgery. Comparison of dosimetric treatment plan quality

    Energy Technology Data Exchange (ETDEWEB)

    Treuer, Harald; Hoevels, Moritz; Luyken, Klaus; Visser-Vandewalle, Veerle; Wirths, Jochen; Ruge, Maximilian [University Hospital Cologne, Department of Stereotaxy and Functional Neurosurgery, Cologne (Germany); Kocher, Martin [University Hospital Cologne, Department of Radiotherapy, Cologne (Germany)

    2014-11-22

    Stereotactic radiosurgery with an adapted linear accelerator (linac-SRS) is an established therapy option for brain metastases, benign brain tumors, and arteriovenous malformations. We intended to investigate whether the dosimetric quality of treatment plans achieved with a CyberKnife (CK) is at least equivalent to that for linac-SRS with circular or micromultileaf collimators (microMLC). A random sample of 16 patients with 23 target volumes, previously treated with linac-SRS, was replanned with CK. Planning constraints were identical dose prescription and clinical applicability. In all cases uniform optimization scripts and inverse planning objectives were used. Plans were compared with respect to coverage, minimal dose within target volume, conformity index, and volume of brain tissue irradiated with ≥ 10 Gy. Generating the CK plan was unproblematic with simple optimization scripts in all cases. With the CK plans, coverage, minimal target volume dosage, and conformity index were significantly better, while no significant improvement could be shown regarding the 10 Gy volume. Multiobjective comparison for the irradiated target volumes was superior in the CK plan in 20 out of 23 cases and equivalent in 3 out of 23 cases. Multiobjective comparison for the treated patients was superior in the CK plan in all 16 cases. The results clearly demonstrate the superiority of the irradiation plan for CK compared to classical linac-SRS with circular collimators and microMLC. In particular, the average minimal target volume dose per patient, increased by 1.9 Gy, and at the same time a 14 % better conformation index seems to be an improvement with clinical relevance. (orig.) [German] Stereotaktische Radiochirurgie mit einem adaptierten Linearbeschleuniger (Linac-SRS) ist eine erfolgreiche und etablierte Therapieoption fuer Hirnmetastasen, benigne Hirntumoren und arteriovenoese Malformationen. Ziel war es, zu untersuchen, ob die mit einem CyberKnife (CK) erreichbare

  20. Small Field Dosimetry Using Optical-Fiber Radioluminescence and Radpos Dosimetry Systems

    DEFF Research Database (Denmark)

    Ploquin, N.; Kertzscher Schwencke, Gustavo Adolfo Vladimir; Vandervoort, E.

    2012-01-01

    as an electromagnetic positioning sensor and a μMOSFET for dose measurement. Materials and Methods: Relative output factors (ROF) for Cyberknife cones ranging from 5 to 60 mm were measured using RL and RADPOS systems. For comparison, measurements were also carried out using a mobileMOSFET system (BEST Medical Canada......) and GafChromic films EBT1 and EBT2 (ISP, USA). The MOSFET detectors in both mobileMOSFET and RADPOS systems were standard sensitivity μMOSFETs (TN502RDM), with a standard bias applied during irradiation. The measurements were performed in a solid water phantom at the depth of 1.5 cm and SSD = 78.5 cm....... Detector readings for each cone were normalized to those for 60 mm cone. For MOSFET detectors in both mobileMOSFET and RADPOS systems, the corrections proposed by Francescon et al. (J Appl Clin Med Phys, 10 (1), 14752, 2009) were applied. Since FWHM of our Cyberknife source is 2.4mm, the μMOSFET...

  1. Obliteration dynamics in cerebral arteriovenous malformations after cyberknife radiosurgery: quantification with sequential nidus volumetry and 3-tesla 3-dimensional time-of-flight magnetic resonance angiography.

    Science.gov (United States)

    Wowra, Berndt; Muacevic, Alexander; Tonn, Jörg-Christian; Schoenberg, Stefan O; Reiser, Maximilian; Herrmann, Karin A

    2009-02-01

    To investigate the time-dependent obliteration of cerebral arteriovenous malformations (cAVM) after CyberKnife radiosurgery (CKRS) (Accuray, Inc., Sunnyvale, CA) by means of sequential 3-T, 3-dimensional (3D), time-of-flight (TOF) magnetic resonance angiography (MRA), and volumetry of the arteriovenous malformation (AVM) nidus. In this prospective study, 3D TOF MRA was performed on 20 patients with cAVMs treated by single-fraction CKRS. Three-dimensional TOF MRA was performed on a 3-T, 32-channel magnetic resonance scanner (Magnetom TIM Trio; Siemens Medical Solutions, Erlangen, Germany) with isotropic voxel size at a spatial resolution of 0.6 x 0.6 x 0.6 mm3. The time-dependent relative decay of the transnidal blood flow evidenced by 3D TOF MRA was referred to as "obliteration dynamics." Volumetry of the nidus size was performed with OsiriX imaging software (OsiriX Foundation, Geneva, Switzerland). All patients had 3 to 4 follow-up examinations at 3- to 6-month intervals over a minimum follow-up period of 9 months. Subtotal obliteration was determined if the residual nidus volume was 5% or less of the initial nidus volume. Stata/IC software (Version 10.0; Stata Corp., College Station, TX) was used for statistical analysis and to identify potential factors of AVM obliteration. Regarding their clinical status, case history, and pretreatments, the participants of this study represent difficult-to-treat cAVM patients. The median nidus volume was 1.8 mL (range, 0.4-12.5 mL); the median minimum dose prescribed to the nidus was 22 Gy (range, 16-24 Gy) delivered to the 67% isodose line (range, 55-80%). CKRS was well tolerated, with complications in 2 patients. No further hemorrhages occurred after RS, except 1 small and clinically inapparent incident. The median follow-up period after RS was 25.0 months (range, 11.7-36.8 months). After RS, a statistically significant obliteration was observed in all patients. However, the obliteration dynamics of the cAVMs showed a

  2. Image guided radiotherapy. Quality control of X ray equipment. S.F.P.M. report nr 29

    International Nuclear Information System (INIS)

    Delpon, Gregory; Aubignac, Leone; Bramoulle, Celine; Boutry, Christine; Guerin, Lucie; Lafay, Frederic; Benoit, David; Garcia, Robin; Jaegle, Enric; Vieillevigne, Laure; Dedieu, Veronique; Ferrrer, Ludovic; Guillhem, Marie-Therese; Lacaze, Brigitte; Mazurier, Jocelyne; Simon, Luc

    2014-01-01

    This report presents different X ray imagery systems used for positioning support in external radiation therapy, and installed in treatment rooms. If portal imagery systems and rail-mounted tomodensitometry systems are not addressed in this document, the authors distinguish and describe various embedded systems in which devices are directly mounted on the treatment apparatus (X-Ray Volume Imaging by Elekta, On Board Imager by Varian), peripheral systems which are independent from the machine (Cyberknife by Accuray and Exatrac by BrainLab), MVCT or Mega Voltage Computed Tomography systems (Tomotherapy by Accuray), and MVCBCT or Megavoltage Cone Beam Computed Tomography systems (Artiste by Siemens). After a brief presentation of these systems, the author present various aspects of quality controls (list, periodicity, test tolerance, tested objects), and then more precisely describe the above-mentioned systems. For each of them, the following aspects are addressed: generator, geometry, image quality, dose, environment and safety, gating module, quality controls

  3. Motion compensation for robotic lung tumour radiotherapy in remote locations: A personalised medicine approach

    Science.gov (United States)

    Ionescu, Clara M.; Copot, Cosmin; Verellen, Dirk

    2017-03-01

    The purpose of this work is to integrate the concept of patient-in-the-closed-loop application with tumour treatment of cancer-diagnosed patients in remote areas. The generic closed loop control objective is effective synchronisation of the radiation focus to the movement of a lung tissue tumour during actual breathing of the patient. This is facilitated by accurate repositioning of a robotic arm manipulator, i.e. we emulate the Cyberknife Robotic Radiosurgery system. Predictive control with disturbance filter is used in this application in a minimalistic model design. Performance of the control structure is validated by means of simulation using real recorded breathing patterns from patients measured in 3D space. Latency in communication protocol is taken into account, given telerobotics involve autonomous operation of a robot interacting with a human being in different location. Our results suggest that the proposed closed loop control structure has practical potential to individualise the treatment and improves accuracy by at least 15%.

  4. Stereotactic body radiation therapy for low- and low-intermediate risk prostate cancer: Is there a dose effect?

    Directory of Open Access Journals (Sweden)

    Alan Jay Katz

    2011-12-01

    Full Text Available This study examines the efficacy and toxicity of two stereotactic body radiation therapy (SBRT dose regimens for treatment of early prostate cancer. Forty-one patients treated with 35 Gy were matched with 41 patients treated with 36.25 Gy. Both patient groups received SBRT in 5 fractions over 5 consecutive days using the CyberKnife. Each group had 37 low-risk patients and 4 intermediate-risk patients. No statistically significant differences were present for age, prostate volume, PSA, Gleason score, stage, or risk between the groups. The dose was prescribed to the 83-87% isodose line to cover the prostate and a 5-mm margin all around, except 3 mm posteriorly. The overall median follow-up is 51 months (range, 45-58 months with a median 54 months and 48 months follow-up for the 35-Gy and 36.25-Gy dose groups, respectively. One biochemical failure occurred in each group yielding a 97.5% freedom from biochemical failure. The PSA response has been favorable for all patients with a mean PSA of 0.1 ng/ml at 4-years. Overall toxicity has been mild with 5% late grade 2 rectal toxicity in both dose groups. Late grade 1 urinary toxicity was equivalent between groups; grade 2 urinary toxicity was 5% (2/41 patients and 10% (4/41 patients in the 35-Gy and 36.25-Gy dose groups (p = 0.6969, respectively. Overall, the highly favorable PSA response, limited biochemical failures, limited toxicity, and limited impact on quality of life in these low- to low-intermediate-risk patients are supportive of excellent long-term results for CyberKnife delivered SBRT.

  5. Use of novel fibre-coupled radioluminescence and RADPOS dosimetry systems for total scatter factor measurements in small fields

    DEFF Research Database (Denmark)

    Ploquin, N.; Kertzscher, Gustavo; Vandervoort, E.

    2015-01-01

    A dosimetry system based on Al2O3:C radioluminescence (RL), and RADPOS, a novel 4D dosimetry system using microMOSFETs, were used to measure total scatter factors, (Sc,p)fclindet, for the CyberKnife robotic radiosugery system. New Monte Carlo calculated correction factors are presented and applied...

  6. SU-E-T-125: Dosimetric Comparison of Intensity Modulated Radiation Therapy Using Robotic Versus Traditional Linac Platform in Prostate Cancer

    International Nuclear Information System (INIS)

    Hayes, T; Rella, J; Yang, J; Sims, C; Fung, C

    2014-01-01

    Purpose: Recent development of an MLC for robotic external beam radiotherapy has the potential of new clinical application in conventionally fractionated radiation therapy. This study offers a dosimetric comparison of IMRT plans using Cyberknife with MLC versus conventional linac plans. Methods: Ten prostate cancer patients treated on a traditional linac with IMRT to 7920cGy at 180cGy/fraction were randomly selected. GTVs were defined as prostate plus proximal seminal vesicles. PTVs were defined as GTV+8mm in all directions except 5mm posteriorly. Conventional IMRT planning was performed on Philips Pinnacle and delivered on a standard linac with CBCT and 10mm collimator leaf width. For each case a Cyberknife plan was created using Accuray Multiplan with same CT data set, contours, and dose constraints. All dosimetric data was transferred to third party software for independent computation of contour volumes and DVH. Delivery efficiency was evaluated using total MU, treatment time, number of beams, and number of segments. Results: Evaluation criteria including percent target coverage, homogeneity index, and conformity index were found to be comparable. All dose constraints from QUANTEC were found to be statistically similar except rectum V50Gy and bladder V65Gy. Average rectum V50Gy was lower for robotic IMRT (30.07%±6.57) versus traditional (34.73%±3.62, p=0.0130). Average bladder V65Gy was lower for robotic (17.87%±12.74) versus traditional (21.03%±11.93, p=0.0405). Linac plans utilized 9 coplanar beams, 48.9±3.8 segments, and 19381±2399MU. Robotic plans utilized 38.4±9.0 non-coplanar beams, 85.5±21.0 segments and 42554.71±16381.54 MU. The average treatment was 15.02±0.60 minutes for traditional versus 20.90±2.51 for robotic. Conclusion: The robotic IMRT plans were comparable to the traditional IMRT plans in meeting the target volume dose objectives. Critical structure dose constraints were largely comparable although statistically significant

  7. Risk-adapted robotic stereotactic body radiation therapy for inoperable early-stage non-small-cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Temming, Susanne; Kocher, Martin; Baus, Wolfgang W.; Semrau, Robert; Baues, Christian; Marnitz, S. [University of Cologne, Department of Radiation Oncology, Center for Integrated Oncology, Cologne (Germany); Stoelben, Erich [Hospital of Cologne, Lung Clinic Merheim, Cologne (Germany); Hagmeyer, Lars [University of Cologne, Bethanien Hospital, Institute of Pneumology, Solingen (Germany); Chang, De-Hua [University of Cologne, Department of Diagnostic and Interventional Radiology, Center for Integrated Oncology, Cologne (Germany); Frank, Konrad [Heart Centre of the University of Cologne, Department III of Internal Medicine, Cologne (Germany); Hekmat, Khosro [University of Cologne, Department of Cardiothoracic Surgery, Center for Integrated Oncology, Cologne (Germany); Wolf, Juergen [University Hospital of Cologne, First Department of Internal Medicine, Center for Integrated Oncology, Cologne (Germany)

    2018-02-15

    To evaluate efficacy and toxicity of stereotactic body radiation therapy (SBRT) with CyberKnife {sup registered} (Accuray, Sunnyvale, CA, USA) in a selected cohort of primary, medically inoperable early-stage non-small cell lung cancer (NSCLC) patients. From 2012 to 2016, 106 patients (median age 74 years, range 50-94 years) with primary NSCLC were treated with SBRT using CyberKnife {sup registered}. Histologic confirmation was available in 87 patients (82%). For mediastinal staging, 92 patients (87%) underwent {sup 18}F-fluorodeoxyglucose positron-emission tomography (18-FDG-PET) and/or endobronchial ultrasound (EBUS)-guided lymph node biopsy or mediastinoscopy. Tumor stage (UICC8, 2017) was IA/B (T1a-c, 1-3 cm) in 86 patients (81%) and IIA (T2a/b, 3-5 cm) in 20 patients (19%). Depending on tumor localization, three different fractionation schedules were used: 3 fractions of 17Gy, 5 fractions of 11Gy, or 8 fractions of 7.5 Gy. Tracking was based on fiducial implants in 13 patients (12%) and on image guidance without markers in 88%. Median follow-up was 15 months (range 0.5-46 months). Acute side effects were mild (fatigue grade 1-2 in 20% and dyspnea grade 1-2 in 17%). Late effects were observed in 4 patients (4%): 3 patients developed pneumonitis requiring therapy (grade 2) and 1 patient suffered a rib fracture (grade 3). In total, 9/106 patients (8%) experienced a local recurrence, actuarial local control rates were 88% (95% confidence interval, CI, 80-96%) at 2 years and 77% (95%CI 56-98%) at 3 years. The median disease-free survival time was 27 months (95%CI 23-31 months). Overall survival was 77% (95%CI 65-85%) at 2 years and 56% (95%CI 39-73%) at 3 years. CyberKnife {sup registered} lung SBRT which allows for real-time tumor tracking and risk-adapted fractionation achieves satisfactory local control and low toxicity rates in inoperable early-stage primary lung cancer patients. (orig.) [German] Untersuchung von Wirkung und Toxizitaet einer stereotaktischen

  8. Treatment planning for MLC based robotic radiosurgery for brain metastases: plan comparison with circular fields and suggestions for planning strategies

    Directory of Open Access Journals (Sweden)

    Schmitt Daniela

    2017-09-01

    Full Text Available To evaluate the possible range of application of the new InCise2 MLC for the CyberKnife M6 system in brain radiosurgery, a plan comparison was made for 10 brain metastases sized between 1.5 and 9cm3 in 10 patients treated in a single fraction each. The target volumes consist of a PTV derived by expanding the GTV by 1mm and were chosen to have diversity in the cohort regarding regularity of shape, location and the structures needed to be blocked for beam transmission in the vicinity. For each case, two treatment plans were optimized: one using the MLC and one using the IRIS-collimator providing variable circular fields. Plan re-quirements were: dose prescription to the 70% isodose line (18 or 20Gy, 100% GTV coverage, ≥98% PTV coverage, undisturbed central high dose region (95% of maximum dose and a conformity index as low as possible. Plan com-parison parameters were: conformity index (CI, high-dose gradient index (GIH, low-dose gradient index (GIL, total number of monitor units (MU and expected treatment time (TT. For all cases, clinically acceptable plans could be gen-erated with the following results (mean±SD for CI, GIH, GIL, MU and TT, respectively for the MLC plans: 1.09±0.03, 2.77±0.26, 2.61±0.08, 4514±830MU and 27±5min and for the IRIS plans: 1.05±0.01, 3.00±0.35, 2.46±0.08, 8557±1335MU and 42±7min. In summary, the MLC plans were on average less conformal and had a shallower dose gradient in the low dose region, but a steeper dose gradient in the high dose region. This is accompanied by a smaller vol-ume receiving 10Gy. A plan by plan comparison shows that usage of the MLC can spare about one half of the MUs and one third of treatment time. From these experiences and results suggestions for MLC planning strategy can be de-duced.

  9. Multi-institutional application of Failure Mode and Effects Analysis (FMEA) to CyberKnife Stereotactic Body Radiation Therapy (SBRT).

    Science.gov (United States)

    Veronese, Ivan; De Martin, Elena; Martinotti, Anna Stefania; Fumagalli, Maria Luisa; Vite, Cristina; Redaelli, Irene; Malatesta, Tiziana; Mancosu, Pietro; Beltramo, Giancarlo; Fariselli, Laura; Cantone, Marie Claire

    2015-06-13

    A multidisciplinary and multi-institutional working group applied the Failure Mode and Effects Analysis (FMEA) approach to assess the risks for patients undergoing Stereotactic Body Radiation Therapy (SBRT) treatments for lesions located in spine and liver in two CyberKnife® Centres. The various sub-processes characterizing the SBRT treatment were identified to generate the process trees of both the treatment planning and delivery phases. This analysis drove to the identification and subsequent scoring of the potential failure modes, together with their causes and effects, using the risk probability number (RPN) scoring system. Novel solutions aimed to increase patient safety were accordingly considered. The process-tree characterising the SBRT treatment planning stage was composed with a total of 48 sub-processes. Similarly, 42 sub-processes were identified in the stage of delivery to liver tumours and 30 in the stage of delivery to spine lesions. All the sub-processes were judged to be potentially prone to one or more failure modes. Nineteen failures (i.e. 5 in treatment planning stage, 5 in the delivery to liver lesions and 9 in the delivery to spine lesions) were considered of high concern in view of the high RPN and/or severity index value. The analysis of the potential failures, their causes and effects allowed to improve the safety strategies already adopted in the clinical practice with additional measures for optimizing quality management workflow and increasing patient safety.

  10. Stereotactic radiotherapy by cyberknife of sub-diaphragm digestive tumors; Radiotherapie stereotaxique par Cyberknife des tumeurs digestives sous diaphragmatiques

    Energy Technology Data Exchange (ETDEWEB)

    Taste, H.; Peiffert, D.; Beckendorf, V.; Marchesi, V.; Noel, A. [Centre Alexis-Vautrin, 54 - Vandoeuvre-les-Nancy (France)

    2009-10-15

    The stereotactic radiotherapy is a low toxic, efficient therapy offering a supplementary curative alternative, with promising first results, confirmed by literature. ts indications, its place in the therapy strategy stay to determine in the clinical research program. (N.C.)

  11. Equivalent (uniform) square field sizes of flattening filter free photon beams

    Science.gov (United States)

    Lechner, Wolfgang; Kuess, Peter; Georg, Dietmar; Palmans, Hugo

    2017-10-01

    Various types of treatment units, such as CyberKnife, TomoTherapy and C-arm linear accelerators (LINACs) are operated using flattening filter free (FFF) photon beams. Their reference dosimetry, however, is currently based on codes of practice that provide data which were primarily developed and tested for high-energy photon beams with flattening filter (WFF). The aim of this work was to introduce equivalent uniform square field sizes of FFF beams to serve as a basis of a unified reference dosimetry procedure applicable to all aforementioned FFF machines. For this purpose, in-house determined experimental data together with published data of the ratio of doses at depths of 20 cm and 10 cm in water (D 20,10) were used to characterize the depth dose distribution of 6 and 10 MV WFF and FFF beams. These data were analyzed for field sizes ranging from 2  ×  2 cm2 to 40  ×  40 cm2. A scatter function that takes the lateral profiles of the individual beams into account was fitted to the experimental data. The lateral profiles of the WFF beams were assumed to be uniform, while those of the FFF beams were approximated using fourth or sixth order polynomials. The scatter functions of the FFF beams were recalculated using a uniform lateral profile (the same as the physical profile of the WFF beams), and are henceforth denoted as virtual uniform FFF beams (VUFFF). The field sizes of the VUFFF beams having the same scatter contribution as the corresponding FFF beams at a given field size were defined as the equivalent uniform square field (EQUSF) size. Data from four different LINACs with 18 different beams in total, as well as a CyberKnife beam, were analyzed. The average values of EQUSFs over all investigated LINACs of the conventional 10  ×  10 cm2 reference fields of 6 MV and 10 MV FFF beams for C-arm LINACs and machine-specific reference fields for CyberKnife and TomoTherapy were 9.5 cm, 9 cm, 5.0 cm and 6.5 cm respectively. The

  12. WE-C-TOUR-T-00: Exhibit Hall Guided Tours-Microdosimeters for Therapy (Wednesday) WE-C-TOUR-T-01

    International Nuclear Information System (INIS)

    2016-01-01

    Tour Leader: Indra Das, NYU Langone Medical Center, New York, NY Tour Guides: Hsui Ai, Indiana University School of Medicine, Indianapolis, IN Paulina Galvis, NYU Langone Medical Center, New York, NY Olga Volotoskova, NYU Langone Medical Center, New York, NY Participating Vendors: IBA PTW – New York RTI Electronics, Inc. Standard Imaging, Inc. Sun Nuclear Corporation Small fields are increasing used in specialized radiation treatments such as Gammaknife, Cyberknife, Tomotherapy, IMRT, VMAT, SRS and SBRT. Due to small field size electron transport creates lateral electronic disequilibrium and thus dosimetry could be very difficult. Microdetectors are used for small field dosimetry which will be discussed in preface of this tour as below: Understanding small field e.g. meaning and definition of small field IAEA definition and approach Characteristics of microdetectors in terms of perturbation, recombination, correction Suitability of microdetectors in small field dosimetry

  13. WE-C-TOUR-T-01: Microdosimeters for Therapy

    International Nuclear Information System (INIS)

    Das, I.

    2016-01-01

    Tour Leader: Indra Das, NYU Langone Medical Center, New York, NY Tour Guides: Hsui Ai, Indiana University School of Medicine, Indianapolis, IN Paulina Galvis, NYU Langone Medical Center, New York, NY Olga Volotoskova, NYU Langone Medical Center, New York, NY Participating Vendors: IBA PTW – New York RTI Electronics, Inc. Standard Imaging, Inc. Sun Nuclear Corporation Small fields are increasing used in specialized radiation treatments such as Gammaknife, Cyberknife, Tomotherapy, IMRT, VMAT, SRS and SBRT. Due to small field size electron transport creates lateral electronic disequilibrium and thus dosimetry could be very difficult. Microdetectors are used for small field dosimetry which will be discussed in preface of this tour as below: Understanding small field e.g. meaning and definition of small field IAEA definition and approach Characteristics of microdetectors in terms of perturbation, recombination, correction Suitability of microdetectors in small field dosimetry

  14. TU-E-TOUR-T-00: Exhibit Hall Guided Tours-Microdosimeters for Therapy (Tuesday)

    International Nuclear Information System (INIS)

    2016-01-01

    Tour Leader: Indra Das, NYU Langone Medical Center, New York, NY Tour Guides: Hsui Ai, Indiana University School of Medicine, Indianapolis, IN Aaron Andersen, Indiana University School of Medicine, Indianapolis, IN Olga Volotoskova, NYU Langone Medical Center, New York, NY Participating Vendors: IBA PTW – New York RTI Electronics, Inc. Standard Imaging, Inc. Sun Nuclear Corporation Small fields are increasing used in specialized radiation treatments such as Gammaknife, Cyberknife, Tomotherapy, IMRT, VMAT, SRS and SBRT. Due to small field size electron transport creates lateral electronic disequilibrium and thus dosimetry could be very difficult. Microdetectors are used for small field dosimetry which will be discussed in preface of this tour as below: Understanding small field e.g. meaning and definition of small field IAEA definition and approach Characteristics of microdetectors in terms of perturbation, recombination, correction Suitability of microdetectors in small field dosimetry

  15. Development and validation of a CT-3D rotational angiography registration method for AVM radiosurgery

    International Nuclear Information System (INIS)

    Stancanello, Joseph; Cavedon, Carlo; Francescon, Paolo; Cerveri, Pietro; Ferrigno, Giancarlo; Colombo, Federico; Perini, Stefano

    2004-01-01

    In this paper a novel technique is proposed and validated for radiosurgery treatment planning of arteriovenous malformations (AVMs). The technique was developed for frameless radiosurgery by means of the CyberKnife, a nonisocentric, linac-based system which allows highly conformed isodose surfaces to be obtained, while also being valid for other treatment strategies. The technique is based on registration between computed tomography (CT) and three-dimensional rotational angiography (3DRA). Tests were initially performed on the effectiveness of the correction method for distortion offered by the angiographic system. These results determined the registration technique that was ultimately chosen. For CT-3DRA registration, a twelve-parameter affine transformation was selected, based on a mutual information maximization algorithm. The robustness of the algorithm was tested by attempting to register data sets increasingly distant from each other, both in translation and rotation. Registration accuracy was estimated by means of the 'full circle consistency test'. A registration quality index (expressed in millimeters) based on these results was also defined. A hybrid subtraction between CT and 3DRA is proposed in order to improve 3D reconstruction. Preprocessing improved the ability of the algorithm to find an acceptable solution to the registration process. The robustness tests showed that data sets must be manually prealigned within approximately 15 mm and 20 deg. with respect to all three directions simultaneously. Results of the consistency test showed agreement between the quality index and registration accuracy stated by visual inspection in 20 good and 10 artificially worsened registration processes. The quality index showed values smaller than the maximum voxel size (mean 0.8 mm compared to 2 mm) for all successful registrations, while it resulted in much greater values (mean 20 mm) for unsuccessful registrations. Once registered, the two data sets can be used for

  16. Multi-staged robotic stereotactic radiosurgery for large cerebral arteriovenous malformations

    International Nuclear Information System (INIS)

    Ding, Chuxiong; Solberg, Timothy D.; Hrycushko, Brian; Medin, Paul; Whitworth, Louis; Timmerman, Robert D.

    2013-01-01

    Purpose: To investigate a multi-staged robotic stereotactic radiosurgery (SRS) delivery technique for the treatment of large cerebral arteriovenous malformations (AVMs). The treatment planning process and strategies to optimize both individual and composite dosimetry are discussed. Methods: Eleven patients with large (30.7 ± 19.2 cm 3 ) AVMs were selected for this study. A fiducial system was designed for fusion of targets between planar angiograms and simulation CT scans. AVMs were contoured based on single contrast CT, MRI and orthogonal angiogram images. AVMs were divided into 3–8 sub-target volumes (3–7 cm 3 ) for sequential treatment at 1–4 week intervals to a prescription dose of 16–20 Gy. Forward and inversely developed treatment plans were optimized for 95% coverage of the total AVM volume by dose summation from each sub-volume, while minimizing dose to surrounding tissues. Dose-volume analysis was used to evaluate the PTV coverage, dose conformality (CI), and R 50 and V 12Gy parameters. Results: The treatment workflow was commissioned and able to localize within 1 mm. Inverse optimization outperformed forward planning for most patients for each index considered. Dose conformality was shown comparable to staged Gamma Knife treatments. Conclusion: The CyberKnife system is shown to be a practical delivery platform for multi-staged treatments of large AVMs using forward or inverse planning techniques

  17. Uterine sarcomas-Recent progress and future challenges

    International Nuclear Information System (INIS)

    Seddon, Beatrice M.; Davda, Reena

    2011-01-01

    Uterine sarcomas are a group of rare tumours that provide considerable challenges in their treatment. Radiological diagnosis prior to hysterectomy is difficult, with the diagnosis frequently made post-operatively. Current staging systems have been unsatisfactory, although a new FIGO staging system specifically for uterine sarcomas has now been introduced, and may allow better grouping of patients according to expected prognosis. While the mainstay of treatment of early disease is a total abdominal hysterectomy, it is less clear whether routine oophorectomy or lymphadenectomy is necessary. Adjuvant pelvic radiotherapy may improve local tumour control in high risk patients, but is not associated with an overall survival benefit. Similarly there is no good evidence for the routine use of adjuvant chemotherapy. For advanced leiomyosarcoma, newer chemotherapy agents including gemcitabine and docetaxel, and trabectedin, offer some promise, while hormonal therapies appear to be more useful in endometrial stromal sarcoma. Novel targeted agents are now being introduced for sarcomas, and uterine sarcomas, and show some indications of activity. Non-pharmacological treatments, including surgical metastatectomy, radiofrequency ablation, and CyberKnife radiotherapy, are important additions to systemic therapy for advanced metastatic disease.

  18. A study on uncertainty by passage of time of stereotactic body radiation therapy for spine metastasis cancer

    International Nuclear Information System (INIS)

    Cho, Yong Wan; Kim, Joo Ho; Ahn, Seung Kwon; Lee, Sang Kyoo; Cho, Jeong Hee

    2015-01-01

    The purpose of this study was to determine the proper treatment time of stereotactic body radiation therapy for spine metastasis cancer by using the image guidance system of CyberKnife(Accuracy Incorporated, USA) which is able to correct movements of patients during the treatment. Fifty seven spine metastasis cancer patients who have stereotactic body radiation therapy of CyberKnife participate, 8 of them with cervical spine cancer, 26 of them with thoracic spine cancer, and 23 of them with lumbar spine cancer. X-ray images acquired during the treatment were classified by treatment site. From the starting point of treatment, motion tendency of patients is analyzed in each section which is divided into every 5 minutes. In case of cervical spine, there is sudden increase of variation in 15 minutes after the treatment starts in rotational direction. In case of thoracic spine, there is no significantly variable section. However, variation increases gradually with the passage of time so that it is assumed that noticeable value comes up in approximately 40 minutes. In case of lumbar spine, sharp increase of variation is seen in 20 minutes in translational and rotational direction. Without having corrections during the treatment, proper treatment time is considered as less than 15 minutes for cervical spine, 40 minutes for thoracic spine, and 20 minutes for lumbar spine. If treatment time is longer than these duration, additional patient alignments are required or PTV margin should be enlarged

  19. A study on uncertainty by passage of time of stereotactic body radiation therapy for spine metastasis cancer

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Wan; Kim, Joo Ho; Ahn, Seung Kwon; Lee, Sang Kyoo; Cho, Jeong Hee [Dept. of Radiation Oncology, Yonsei Cancer Center, Seoul (Korea, Republic of)

    2015-06-15

    The purpose of this study was to determine the proper treatment time of stereotactic body radiation therapy for spine metastasis cancer by using the image guidance system of CyberKnife(Accuracy Incorporated, USA) which is able to correct movements of patients during the treatment. Fifty seven spine metastasis cancer patients who have stereotactic body radiation therapy of CyberKnife participate, 8 of them with cervical spine cancer, 26 of them with thoracic spine cancer, and 23 of them with lumbar spine cancer. X-ray images acquired during the treatment were classified by treatment site. From the starting point of treatment, motion tendency of patients is analyzed in each section which is divided into every 5 minutes. In case of cervical spine, there is sudden increase of variation in 15 minutes after the treatment starts in rotational direction. In case of thoracic spine, there is no significantly variable section. However, variation increases gradually with the passage of time so that it is assumed that noticeable value comes up in approximately 40 minutes. In case of lumbar spine, sharp increase of variation is seen in 20 minutes in translational and rotational direction. Without having corrections during the treatment, proper treatment time is considered as less than 15 minutes for cervical spine, 40 minutes for thoracic spine, and 20 minutes for lumbar spine. If treatment time is longer than these duration, additional patient alignments are required or PTV margin should be enlarged.

  20. Stereotactic Body Radiation Therapy for Patients with Heavily Pretreated Liver Metastases and Liver Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Lanciano, Rachelle; Lamond, John; Yang, Jun; Feng, Jing; Arrigo, Steve; Good, Michael; Brady, Luther, E-mail: rlancmd@gmail.com [Philadelphia CyberKnife, Drexel University, Havertown, PA (United States)

    2012-03-09

    We present our initial experience with CyberKnife stereotactic body radiation therapy (SBRT) in a heavily pretreated group of patients with liver metastases and primary liver tumors. From October 2007 to June 2009, 48 patients were treated at the Philadelphia CyberKnife Center for liver metastases or primary liver tumors. We report on 30 patients with 41 discrete lesions (1–4 tumors per patient) who received an ablative radiation dose (BED ≥ 79.2 Gy10 = 66 Gy EQD2). The treatment goal was to achieve a high SBRT dose to the liver tumor while sparing at least 700 cc of liver from radiation doses above 15 Gy. Twenty-three patients were treated with SBRT for metastatic cancer to the liver; the remainder (n = 7) were primary liver tumors. Eighty-seven percent of patients had prior systemic chemotherapy with a median 24 months from diagnosis to SBRT; 37% had prior liver directed therapy. Local control was assessed for 28 patients (39 tumors) with 4 months or more follow-up. At a median follow-up of 22 months (range, 10–40 months), 14/39 (36%) tumors had documented local failure. A decrease in local failure was found with higher doses of SBRT (p = 0.0237); 55% of tumors receiving a BED ≤ 100 Gy10 (10/18) had local failure compared with 19% receiving a BED > 100 Gy10 (4/21). The 2-year actuarial rate of local control for tumors treated with BED > 100 Gy10 was 75% compared to 38% for those patients treated with BED ≤ 100 Gy10 (p = 0.04). At last follow-up, 22/30 patients (73%) had distant progression of disease. Overall, seven patients remain alive with a median survival of 20 months from treatment and 57 months from diagnosis. To date, no patient experienced persistent or severe adverse effects. Despite the heavy pretreatment of these patients, SBRT was well tolerated with excellent local control rates when adequate doses (BED > 100 Gy10) were used. Median survival was limited secondary to development of further metastatic disease in the majority of patients.

  1. SU-E-T-11: A Dosimetric Comparison of Robotic Prostatic Radiosugery Using Multi- Leaf Collimation Vs Circular Collimators

    Energy Technology Data Exchange (ETDEWEB)

    Feng, J; Yang, J; Lamond, J; Lavere, N; Laciano, R; Ding, W; Arrigo, S; Brady, L [Philadelphia Cyberknife, Philadelphia, PA (United States)

    2014-06-01

    Purpose: The study compared the dosimetry plans of Stereotatic Body Radiotherapy (SBRT) prostate cancer patients using the M6 Cyberknife with Multi-leaf Collimation (MLC) compared with the plans using G4 Cyberknife with circular collimators. Methods: Eight previously treated prostate cancer patients' SBRT plans using circular collimators, designed with Multiplan v3.5.3, were used as a benchmark. The CT, contours and the optimization scripts were imported into Multiplan v5.0 system and replanned with MLC. The same planning objectives were used: more than 95% of PTV received 36.25Gy, 90% of prostate received 40Gy and maximum dose <45Gy, in five fractions. For organs at risk, less than 1cc of rectum received 36Gy and less than 10cc of bladder received 37Gy. Plans were evaluated on parameters derived from dose volume. The beam number, MU and delivery time were recorded to compare the treatment efficiency. Results: The mean CTV volume was 41.3cc (27.5∼57.6cc) and mean PTV volume was 76.77cc (59.1∼99.7cc). The mean PTV coverage was comparable between MLC (98.87%) and cone (98.74%). MLC plans had a slightly more favorable homogeneity index (1.22) and conformity index (1.17), than the cone (1.24 and 1.15). The mean rectum volume of 36 Gy (0.52cc) of MLC plans was slightly larger than cone (0.38cc) and the mean bladder volume of 37 Gy was smaller in MLC (1.82cc) than in cone plans (3.09cc). The mean number of nodes and beams were 65.9 and 80.5 in MLC vs 65.9 and 203.6 in cone. The mean MUs were significantly less for MLC plans (24,228MUs) than cone (32,347MUs). The total delivery time (which included 5 minutes for setup) was less, 29.6min (26∼32min) for MLC vs 45min (35∼55min) for cone. Conclusion: While the differences in the dosimetry between the MLC and circular collimator plans were rather minor, the MLC plans were much more efficient and required significantly less treatment time.

  2. SU-F-T-485: Independent Remote Audits for TG51 NonCompliant Photon Beams Performed by the IROC Houston QA Center

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez, P; Molineu, A; Lowenstein, J; Taylor, P; Kry, S; Followill, D [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: IROC-H conducts external audits for output check verification of photon and electron beams. Many of these beams can meet the geometric requirements of the TG 51 calibration protocol. For those photon beams that are non TG 51 compliant like Elekta GammaKnife, Accuray CyberKnife and TomoTherapy, IROC-H has specific audit tools to monitor the reference calibration. Methods: IROC-H used its TLD and OSLD remote monitoring systems to verify the output of machines with TG 51 non compliant beams. Acrylic OSLD miniphantoms are used for the CyberKnife. Special TLD phantoms are used for TomoTherapy and GammaKnife machines to accommodate the specific geometry of each machine. These remote audit tools are sent to institutions to be irradiated and returned to IROC-H for analysis. Results: The average IROC-H/institution ratios for 480 GammaKnife, 660 CyberKnife and 907 rotational TomoTherapy beams are 1.000±0.021, 1.008±0.019, 0.974±0.023, respectively. In the particular case of TomoTherapy, the overall ratio is 0.977±0.022 for HD units. The standard deviations of all results are consistent with values determined for TG 51 compliant photon beams. These ratios have shown some changes compared to values presented in 2008. The GammaKnife results were corrected by an experimentally determined scatter factor of 1.025 in 2013. The TomoTherapy helical beam results are now from a rotational beam whereas in 2008 the results were from a static beam. The decision to change modality was based on recommendations from the users. Conclusion: External audits of beam outputs is a valuable tool to confirm the calibrations of photon beams regardless of whether the machine is TG 51 or TG 51 non compliant. The difference found for TomoTherapy units is under investigation. This investigation was supported by IROC grant CA180803 awarded by the NCI.

  3. SU-F-T-485: Independent Remote Audits for TG51 NonCompliant Photon Beams Performed by the IROC Houston QA Center

    International Nuclear Information System (INIS)

    Alvarez, P; Molineu, A; Lowenstein, J; Taylor, P; Kry, S; Followill, D

    2016-01-01

    Purpose: IROC-H conducts external audits for output check verification of photon and electron beams. Many of these beams can meet the geometric requirements of the TG 51 calibration protocol. For those photon beams that are non TG 51 compliant like Elekta GammaKnife, Accuray CyberKnife and TomoTherapy, IROC-H has specific audit tools to monitor the reference calibration. Methods: IROC-H used its TLD and OSLD remote monitoring systems to verify the output of machines with TG 51 non compliant beams. Acrylic OSLD miniphantoms are used for the CyberKnife. Special TLD phantoms are used for TomoTherapy and GammaKnife machines to accommodate the specific geometry of each machine. These remote audit tools are sent to institutions to be irradiated and returned to IROC-H for analysis. Results: The average IROC-H/institution ratios for 480 GammaKnife, 660 CyberKnife and 907 rotational TomoTherapy beams are 1.000±0.021, 1.008±0.019, 0.974±0.023, respectively. In the particular case of TomoTherapy, the overall ratio is 0.977±0.022 for HD units. The standard deviations of all results are consistent with values determined for TG 51 compliant photon beams. These ratios have shown some changes compared to values presented in 2008. The GammaKnife results were corrected by an experimentally determined scatter factor of 1.025 in 2013. The TomoTherapy helical beam results are now from a rotational beam whereas in 2008 the results were from a static beam. The decision to change modality was based on recommendations from the users. Conclusion: External audits of beam outputs is a valuable tool to confirm the calibrations of photon beams regardless of whether the machine is TG 51 or TG 51 non compliant. The difference found for TomoTherapy units is under investigation. This investigation was supported by IROC grant CA180803 awarded by the NCI

  4. Stereotactic body radiotherapy for low-risk prostate cancer: five-year outcomes

    Directory of Open Access Journals (Sweden)

    King Christopher R

    2011-01-01

    Full Text Available Abstract Purpose Hypofractionated, stereotactic body radiotherapy (SBRT is an emerging treatment approach for prostate cancer. We present the outcomes for low-risk prostate cancer patients with a median follow-up of 5 years after SBRT. Method and Materials Between Dec. 2003 and Dec. 2005, a pooled cohort of 41 consecutive patients from Stanford, CA and Naples, FL received SBRT with CyberKnife for clinically localized, low-risk prostate cancer. Prescribed dose was 35-36.25 Gy in five fractions. No patient received hormone therapy. Kaplan-Meier biochemical progression-free survival (defined using the Phoenix method and RTOG toxicity outcomes were assessed. Results At a median follow-up of 5 years, the biochemical progression-free survival was 93% (95% CI = 84.7% to 100%. Acute side effects resolved within 1-3 months of treatment completion. There were no grade 4 toxicities. No late grade 3 rectal toxicity occurred, and only one late grade 3 genitourinary toxicity occurred following repeated urologic instrumentation. Conclusion Five-year results of SBRT for localized prostate cancer demonstrate the efficacy and safety of shorter courses of high dose per fraction radiation delivered with SBRT technique. Ongoing clinical trials are underway to further explore this treatment approach.

  5. Stereotactic lesioning for mental illness

    International Nuclear Information System (INIS)

    Kim, M.-C.; Lee, T.-K.

    2008-01-01

    The authors report stereotactically created lesioning by radiofrequency or Cyberknife radiosurgery for patients with mental illness. Since 1993, thirty-eight patients have undergone stereotactic psychosurgery for medically intractable mental illnesses. Two patients had aggressive behavior. Twenty-five patients suffered from Obsessive-Compulsive Disorder (OCD) and ten patients had depression. Another patient suffered from atypical psychosis. Bilateral amygdalotomy and subcaudate tractotomy were done for aggressive behavior. Limbic leucotomy or anterior cingulotomy was done for CCD and subcaudate tractotomy with or without cingulotomy was done for depression. In twenty-three patients, the lesions were made by a radiofrequency (RF) lesion generator. In fifteen cases, the lesions were made with Cyberknife Radiosurgery (CKRS). The Overt Aggression Scale (OAS) declined from 8 to 2 with clinical improvement during follow up period. With long-term follow up (meaning 57 months) in 25 OCDs, the mean Yale Brown Obsessive Compulsive Score (YBOCS) declined from 34 to 13 (n = 25). The Hamilton Depression scale (HAMD) for ten patients with depression declined from 38.5 to 10.5 (n = 10). There was no operative mortality and no significant morbidity except one case with transient urinary incontinence. Authors suggest that stereotactic psychosurgery by RF and CKRS could be a safe and effective means of treating some medically intractable mental illnesses. (author)

  6. Beam monitoring in radiotherapy and hadron-therapy

    International Nuclear Information System (INIS)

    Fontbonne, J.M.

    2012-01-01

    Radiotherapy techniques have evolved over the past twenty years. For photon beams, the development of tools such as multi leaf collimators, machines such as Cyberknife or tomo-therapy, have improved the conformation of treatments to the tumor volume and lowered maximum dose to healthy tissue. In another register, the use of proton-therapy is expanding in all countries and the development of carbon ions beams for hadron-therapy is also increasing. If techniques improve, the control requirements for the monitoring of the dose administered to patients are always the same. This document presents, first, the ins and outs of the different techniques of external beam radiotherapy: photon treatments, protons and hadrons. Starting from the basis of clinical requirements, it sets the variables to be measured in order to ensure the quality of treatment for the different considered modalities. It then describes some implementations, based on precise and rigorous specifications, for the monitoring and measurement of beams delivered by external beam radiotherapy equipments. Two instrumental techniques are particularly highlighted, plastic scintillators dosimetry for the control of megavoltage photon beams and ionization chamber dosimetry applied to proton-therapy or radiobiology experiments conducted at the GANIL facility. Analyzes and perspectives, based on the recent developments of treatment techniques, are delivered in conclusion and can serve as guide for future instrumental developments. (author)

  7. Predictive local receptive fields based respiratory motion tracking for motion-adaptive radiotherapy.

    Science.gov (United States)

    Yubo Wang; Tatinati, Sivanagaraja; Liyu Huang; Kim Jeong Hong; Shafiq, Ghufran; Veluvolu, Kalyana C; Khong, Andy W H

    2017-07-01

    Extracranial robotic radiotherapy employs external markers and a correlation model to trace the tumor motion caused by the respiration. The real-time tracking of tumor motion however requires a prediction model to compensate the latencies induced by the software (image data acquisition and processing) and hardware (mechanical and kinematic) limitations of the treatment system. A new prediction algorithm based on local receptive fields extreme learning machines (pLRF-ELM) is proposed for respiratory motion prediction. All the existing respiratory motion prediction methods model the non-stationary respiratory motion traces directly to predict the future values. Unlike these existing methods, the pLRF-ELM performs prediction by modeling the higher-level features obtained by mapping the raw respiratory motion into the random feature space of ELM instead of directly modeling the raw respiratory motion. The developed method is evaluated using the dataset acquired from 31 patients for two horizons in-line with the latencies of treatment systems like CyberKnife. Results showed that pLRF-ELM is superior to that of existing prediction methods. Results further highlight that the abstracted higher-level features are suitable to approximate the nonlinear and non-stationary characteristics of respiratory motion for accurate prediction.

  8. SU-E-J-199: Evaluation of Motion Tracking Effects On Stereotactic Body Radiotherapy of Abdominal Targets

    Energy Technology Data Exchange (ETDEWEB)

    Monterroso, M; Dogan, N; Yang, Y [University Miami, Miami, FL (United States)

    2014-06-01

    Purpose: To evaluate the effects of respiratory motion on the delivered dose distribution of CyberKnife motion tracking-based stereotactic body radiotherapy (SBRT) of abdominal targets. Methods: Four patients (two pancreas and two liver, and all with 4DCT scans) were retrospectively evaluated. A plan (3D plan) using CyberKnife Synchrony was optimized on the end-exhale phase in the CyberKnife's MultiPlan treatment planning system (TPS), with 40Gy prescribed in 5 fractions. A 4D plan was then created following the 4D planning utility in the MultiPlan TPS, by recalculating dose from the 3D plan beams on all 4DCT phases, with the same prescribed isodose line. The other seven phases of the 4DCT were then deformably registered to the end-exhale phase for 4D dose summation. Doses to the target and organs at risk (OAR) were compared between 3D and 4D plans for each patient. The mean and maximum doses to duodenum, liver, spinal cord and kidneys, and doses to 5cc of duodenum, 700cc of liver, 0.25cc of spinal cord and 200cc of kidneys were used. Results: Target coverage in the 4D plans was about 1% higher for two patients and about 9% lower in the other two. OAR dose differences between 3D and 4D varied among structures, with doses as much as 8.26Gy lower or as much as 5.41Gy higher observed in the 4D plans. Conclusion: The delivered dose can be significantly different from the planned dose for both the target and OAR close to the target, which is caused by the relative geometry change while the beams chase the moving target. Studies will be performed on more patients in the future. The differences of motion tracking versus passive motion management with the use of internal target volumes will also be investigated.

  9. Quantitative assessment of inter-observer variability in target volume delineation on stereotactic radiotherapy treatment for pituitary adenoma and meningioma near optic tract

    International Nuclear Information System (INIS)

    Yamazaki, Hideya; Ogita, Mikio; Yamashita, Koichi; Kotsuma, Tadayuki; Shiomi, Hiroya; Tsubokura, Takuji; Kodani, Naohiro; Nishimura, Takuya; Aibe, Norihiro; Udono, Hiroki; Nishikata, Manabu; Baba, Yoshimi

    2011-01-01

    To assess inter-observer variability in delineating target volume and organs at risk in benign tumor adjacent to optic tract as a quality assurance exercise. We quantitatively analyzed 21 plans made by 11 clinicians in seven CyberKnife centers. The clinicians were provided with a raw data set (pituitary adenoma and meningioma) including clinical information, and were asked to delineate the lesions and create a treatment plan. Their contouring and plans (10 adenoma and 11 meningioma plans), were then compared. In addition, we estimated the influence of differences in contouring by superimposing the respective contours onto a default plan. The median planning target volume (PTV) and the ratio of the largest to the smallest contoured volume were 9.22 cm 3 (range, 7.17 - 14.3 cm 3 ) and 1.99 for pituitary adenoma, and 6.86 cm 3 (range 6.05 - 14.6 cm 3 ) and 2.41 for meningioma. PTV volume was 10.1 ± 1.74 cm 3 for group 1 with a margin of 1 -2 mm around the CTV (n = 3) and 9.28 ± 1.8 cm 3 (p = 0.51) for group 2 with no margin (n = 7) in pituitary adenoma. In meningioma, group 1 showed larger PTV volume (10.1 ± 3.26 cm 3 ) than group 2 (6.91 ± 0.7 cm 3 , p = 0.03). All submitted plan keep the irradiated dose to optic tract within the range of 50 Gy (equivalent total doses in 2 Gy fractionation). However, contours superimposed onto the dose distribution of the default plan indicated that an excessive dose 23.64 Gy (up to 268% of the default plan) in pituitary adenoma and 24.84 Gy (131% of the default plan) in meningioma to the optic nerve in the contours from different contouring. Quality assurance revealed inter-observer variability in contour delineation and their influences on planning for pituitary adenoma and meningioma near optic tract

  10. Sci-Fri AM: Quality, Safety, and Professional Issues 02: Recent work on TQC Suite and Data from a National survey on Community Uptake

    Energy Technology Data Exchange (ETDEWEB)

    Malkoske, Kyle; Nielsen, Michelle; Brown, Erika; Diamond, Kevin; Frenière, Normand; Grant, John; Pomerleau-Dalcourt, Natalie; Schella, Jason; Schreiner, L. John; Tantot, Laurent; Barajas, Eduardo Villareal; Sasaki, David; Milette, Marie-Pierre; Bertrand, Marie-Joëlle; Bissonnette, Jean-Pierre [Royal Victoria Hospital (Canada)

    2016-08-15

    The Canadian Partnership for Quality Radiotherapy (CPQR) and the Canadian Organization of Medical Physicist’s (COMP) Quality Assurance and Radiation Safety Advisory Committee (QARSAC) have worked together in the development of a suite of Technical Quality Control (TQC) Guidelines for radiation treatment equipment and technologies, that outline specific performance objectives and criteria that equipment should meet in order to assure an acceptable level of radiation treatment quality. Early community engagement and uptake survey data showed 70% of Canadian centers are part of this process and that the data in the guideline documents reflect, and are influencing the way Canadian radiation treatment centres run their technical quality control programs. As the TQC development framework matured as a cross-country initiative, guidance documents have been developed in many clinical technologies. Recently, there have been new TQC documents initiated for Gamma Knife and Cyberknife technologies where the entire communities within Canada are involved in the review process. At the same time, QARSAC reviewed the suite as a whole for the first time and it was found that some tests and tolerances overlapped across multiple documents as single tests could pertain to multiple quality control areas. The work to streamline the entire suite has allowed for improved usability of the suite while keeping the integrity of single quality control areas. The suite will be published by the JACMP, in the coming year.

  11. Sci-Fri AM: Quality, Safety, and Professional Issues 02: Recent work on TQC Suite and Data from a National survey on Community Uptake

    International Nuclear Information System (INIS)

    Malkoske, Kyle; Nielsen, Michelle; Brown, Erika; Diamond, Kevin; Frenière, Normand; Grant, John; Pomerleau-Dalcourt, Natalie; Schella, Jason; Schreiner, L. John; Tantot, Laurent; Barajas, Eduardo Villareal; Sasaki, David; Milette, Marie-Pierre; Bertrand, Marie-Joëlle; Bissonnette, Jean-Pierre

    2016-01-01

    The Canadian Partnership for Quality Radiotherapy (CPQR) and the Canadian Organization of Medical Physicist’s (COMP) Quality Assurance and Radiation Safety Advisory Committee (QARSAC) have worked together in the development of a suite of Technical Quality Control (TQC) Guidelines for radiation treatment equipment and technologies, that outline specific performance objectives and criteria that equipment should meet in order to assure an acceptable level of radiation treatment quality. Early community engagement and uptake survey data showed 70% of Canadian centers are part of this process and that the data in the guideline documents reflect, and are influencing the way Canadian radiation treatment centres run their technical quality control programs. As the TQC development framework matured as a cross-country initiative, guidance documents have been developed in many clinical technologies. Recently, there have been new TQC documents initiated for Gamma Knife and Cyberknife technologies where the entire communities within Canada are involved in the review process. At the same time, QARSAC reviewed the suite as a whole for the first time and it was found that some tests and tolerances overlapped across multiple documents as single tests could pertain to multiple quality control areas. The work to streamline the entire suite has allowed for improved usability of the suite while keeping the integrity of single quality control areas. The suite will be published by the JACMP, in the coming year.

  12. Radiotherapy in stereotactic conditions with CyberKnife of primitive or secondary hepatic lesions: lessons learnt by the Alexis-Vautrin Centre

    International Nuclear Information System (INIS)

    Taste-George, H.; Peiffert, D.

    2010-01-01

    The author report the experience gained on patients treated by irradiation in stereotactic conditions for primitive or secondary hepatic lesions. Thirty three patients have been treated, 22 suffering from secondary lesions and 11 from primitive lesions. The treatment technique is not much constraining for the patient, is not much toxic, and provides a high local tumour control. Short communication

  13. Non small cells stage I bronchial cancers: three-dimensional radiotherapy and radiotherapy in stereotactic conditions; Cancers bronchiques non a petites cellules de stade I: radiotherapie tridimensionnelle et radiotherapie en conditions stereotaxiques

    Energy Technology Data Exchange (ETDEWEB)

    Schipman, B.; Bosset, J.F. [CHU, 25 - Besancon (France); Marchesi, V.; Beckendorf, V.; Desandes, E.; Peiffert, D. [CRLCC Alexis-Vautrin, 54 - Vandaeuvre-les-Nancy (France); Bosset, M. [CHU, 26 - Valence (France)

    2010-10-15

    The authors report a comparison between three-dimensional conformation radiotherapy and robotic irradiation in stereotactic conditions (with CyberKnife) for patients suffering from a bronchial cancer with no small cells of stage I. Acute and late toxicity have been recorded, and the monitoring comprised a clinic examination and a thoracic scanography. The external radiotherapy results in an important local control rate and an acceptable toxicity. Some prospective studies are still needed to compare three-dimensional conformation respiratory-gated radiotherapy and radiotherapy in stereotactic conditions. Short communication

  14. Five Fraction Image-Guided Radiosurgery for Primary and Recurrent Meningiomas

    Directory of Open Access Journals (Sweden)

    Eric Karl Oermann

    2013-08-01

    Full Text Available Purpose: Benign tumors that arise from the meninges can be difficult to treat due to their potentially large size and proximity to critical structures such as cranial nerves and sinuses. Single fraction radiosurgery may increase the risk of symptomatic peritumoral edema. In this study, we report our results on the efficacy and safety of five fraction image-guided radiosurgery for benign meningiomas. Materials/Methods: Clinical and radiographic data from 38 patients treated with five fraction radiosurgery were reviewed retrospectively. Mean tumor volume was 3.83mm3 (range, 1.08-20.79 mm3. Radiation was delivered using the CyberKnife, a frameless robotic image-guided radiosurgery system with a median total dose of 25 Gy (range, 25 Gy-35 Gy. Results: The median follow-up was 20 months. Acute toxicity was minimal with eight patients (21% requiring a short course of steroids for headache at the end of treatment. Pre-treatment neurological symptoms were present in 24 patients (63.2%. Post treatment, neurological symptoms resolved completely in 14 patients (58.3%, and were persistent in eight patients (33.3%. There were no local failures, 24 tumors remained stable (64% and 14 regressed (36%. Pre-treatment peritumoral edema was observed in five patients (13.2%. Post-treatment asymptomatic peritumoral edema developed in five additional patients (13.2%. On multivariate analysis, pre-treatment peritumoral edema and location adjacent to a large vein were significant risk factors for radiographic post-treatment edema (p = 0.001 and p = 0.026 respectively. Conclusions: These results suggest that five fraction image-guided radiosurgery is well tolerated with a response rate for neurologic symptoms that is similar to other standard treatment options. Rates of peritumoral edema and new cranial nerve deficits following five fraction radiosurgery were low. Longer follow-up is required to validate the safety and long-term effectiveness of this treatment approach.

  15. Sexual Function After Stereotactic Body Radiotherapy for Prostate Cancer: Results of a Prospective Clinical Trial

    International Nuclear Information System (INIS)

    Wiegner, Ellen A.; King, Christopher R.

    2010-01-01

    Purpose: To study the sexual quality of life for prostate cancer patients after stereotactic body radiotherapy (SBRT). Methods and Materials: Using the Expanded Prostate Cancer Index Composite (EPIC)-validated quality-of-life questionnaire, the sexual function of 32 consecutive patients who received prostate SBRT in a prospective Phase II clinical trial were analyzed at baseline, and at median times of 4, 12, 20, and 50 months after treatment. SBRT consisted of 36.25 Gy in five fractions of 7.25 Gy using the Cyberknife. No androgen deprivation therapy was given. The use of erectile dysfunction (ED) medications was monitored. A comprehensive literature review for radiotherapy-alone modalities based on patient self-reported questionnaires served as historical comparison. Results: Median age at treatment was 67.5 years, and median follow-up was 35.5 months (minimum 12 months). The mean EPIC sexual domain summary score, sexual function score, and sexual bother score decreased by 45%, 49%, and 25% respectively at 50 months follow-up. These differences reached clinical relevance by 20 months after treatment. Baseline ED rate was 38% and increased to 71% after treatment (p = 0.024). Use of ED medications was 3% at baseline and progressed to 25%. For patients aged <70 years at follow-up, 60% maintained satisfactory erectile function after treatment compared with only 12% aged ≥70 years (p = 0.008). Penile bulb dose was not associated with ED. Conclusions: The rates of ED after treatment appear comparable to those reported for other modalities of radiotherapy. Given the modest size of this study and the uncertainties in the physiology of radiotherapy-related ED, these results merit further investigations.

  16. WE-AB-BRB-10: Filmless QA of CyberKnife MLC-Collimated and Iris-Collimated Fields

    International Nuclear Information System (INIS)

    Gersh, J

    2015-01-01

    Purpose: Current methods of CK field shape QA is based on the use of radiochromic film. Though accurate results can be attained, these methods are prone to error, time consuming, and expensive. The techniques described herein perform similar QA using the FOIL Detector (Field, Output, and Image Localization). A key feature of this in-house QA solution, and central to this study, is an aSi flat-panel detector which provides the user with the means to perform accurate, immediate, and quantitative field analysis. Methods: The FOIL detector is automatically aligned in the CK beam using fiducial markers implanted within the detector case. Once the system is aligned, a treatment plan is delivered which irradiates the flat-panel imager using the field being tested. The current study tests each of the clinically-used fields shaped using the Iris variable-aperture collimation system using a plan which takes 6 minutes to deliver. The user is immediately provided with field diameter and beam profile, as well as a comparison to baseline values. Additionally, the detector is used to acquire and analyze leaf positions of the InCise multi-leaf collimation system. Results: Using a 6-minute plan consisting of 11 beams of 25MU-per-beam, the FOIL detector provided the user with a quantitative analysis of all clinically-used field shapes. The FOIL detector was also able to clearly resolve field edge junctions in a picket fence test, including slight over-travel of individual leaves as well as inter-leaf leakage. Conclusion: The FOIL system provided comparable field diameter and profile data when compared to methods using film; providing results much faster and with 5% of the MU used for film. When used with the MLC system, the FOIL detector provided the means for immediate quantification of the performance of the system through analysis of leaf positions in a picket fence test field. Author is the President/Owner of Spectrum Medical Physics, LLC, a company which maintains contracts

  17. WE-AB-BRB-10: Filmless QA of CyberKnife MLC-Collimated and Iris-Collimated Fields

    Energy Technology Data Exchange (ETDEWEB)

    Gersh, J [Gibbs Cancer Center and Research Institute - Pelham, Greer, SC (United States); Spectrum Medical Physics, LLC, Greenville, SC (United States)

    2015-06-15

    Purpose: Current methods of CK field shape QA is based on the use of radiochromic film. Though accurate results can be attained, these methods are prone to error, time consuming, and expensive. The techniques described herein perform similar QA using the FOIL Detector (Field, Output, and Image Localization). A key feature of this in-house QA solution, and central to this study, is an aSi flat-panel detector which provides the user with the means to perform accurate, immediate, and quantitative field analysis. Methods: The FOIL detector is automatically aligned in the CK beam using fiducial markers implanted within the detector case. Once the system is aligned, a treatment plan is delivered which irradiates the flat-panel imager using the field being tested. The current study tests each of the clinically-used fields shaped using the Iris variable-aperture collimation system using a plan which takes 6 minutes to deliver. The user is immediately provided with field diameter and beam profile, as well as a comparison to baseline values. Additionally, the detector is used to acquire and analyze leaf positions of the InCise multi-leaf collimation system. Results: Using a 6-minute plan consisting of 11 beams of 25MU-per-beam, the FOIL detector provided the user with a quantitative analysis of all clinically-used field shapes. The FOIL detector was also able to clearly resolve field edge junctions in a picket fence test, including slight over-travel of individual leaves as well as inter-leaf leakage. Conclusion: The FOIL system provided comparable field diameter and profile data when compared to methods using film; providing results much faster and with 5% of the MU used for film. When used with the MLC system, the FOIL detector provided the means for immediate quantification of the performance of the system through analysis of leaf positions in a picket fence test field. Author is the President/Owner of Spectrum Medical Physics, LLC, a company which maintains contracts

  18. Determination of gonad doses during robotic stereotactic radiosurgery for various tumor sites

    International Nuclear Information System (INIS)

    Zorlu, Faruk; Dugel, Gozde; Ozyigit, Gokhan; Hurmuz, Pervin; Cengiz, Mustafa; Yildiz, Ferah; Akyol, Fadil; Gurkaynak, Murat

    2013-01-01

    Purpose: The authors evaluated the absorbed dose received by the gonads during robotic stereotactic radiosurgery (SRS) for the treatment of different tumor localizations. Methods: The authors measured the gonad doses during the treatment of head and neck, thoracic, abdominal, or pelvic tumors in both RANDO phantom and actual patients. The computerized tomography images were transferred to the treatment planning system. The contours of tumor and critical organs were delineated on each slice, and treatment plans were generated. Measurements for gonad doses were taken from the geometric projection of the ovary onto the skin for female patients, and from the scrotal skin for male patients by attaching films and Thermoluminescent dosimeters (TLDs). SRS was delivered with CyberKnife (Accuray Inc., Sunnyvale, CA). Results: The median gonadal doses with TLD and film dosimeter in actual patients were 0.19 Gy (range, 0.035–2.71 Gy) and 0.34 Gy (range, 0.066–3.18 Gy), respectively. In the RANDO phantom, the median ovarian doses with TLD and film dosimeter were 0.08 Gy (range, 0.03–0.159 Gy) and 0.05 Gy (range, 0.015–0.13 Gy), respectively. In the RANDO phantom, the median testicular doses with TLD and film dosimeter were 0.134 Gy (range 0.056–1.97 Gy) and 0.306 Gy (range, 0.065–2.25 Gy). Conclusions: Gonad doses are below sterility threshold in robotic SRS for different tumor localizations. However, particular attention should be given to gonads during robotic SRS for pelvic tumors.

  19. Determination of gonad doses during robotic stereotactic radiosurgery for various tumor sites

    Energy Technology Data Exchange (ETDEWEB)

    Zorlu, Faruk; Dugel, Gozde; Ozyigit, Gokhan; Hurmuz, Pervin; Cengiz, Mustafa; Yildiz, Ferah; Akyol, Fadil; Gurkaynak, Murat [Hacettepe University Faculty of Medicine, Department of Radiation Oncology, Ankara 06100 (Turkey)

    2013-04-15

    Purpose: The authors evaluated the absorbed dose received by the gonads during robotic stereotactic radiosurgery (SRS) for the treatment of different tumor localizations. Methods: The authors measured the gonad doses during the treatment of head and neck, thoracic, abdominal, or pelvic tumors in both RANDO phantom and actual patients. The computerized tomography images were transferred to the treatment planning system. The contours of tumor and critical organs were delineated on each slice, and treatment plans were generated. Measurements for gonad doses were taken from the geometric projection of the ovary onto the skin for female patients, and from the scrotal skin for male patients by attaching films and Thermoluminescent dosimeters (TLDs). SRS was delivered with CyberKnife (Accuray Inc., Sunnyvale, CA). Results: The median gonadal doses with TLD and film dosimeter in actual patients were 0.19 Gy (range, 0.035-2.71 Gy) and 0.34 Gy (range, 0.066-3.18 Gy), respectively. In the RANDO phantom, the median ovarian doses with TLD and film dosimeter were 0.08 Gy (range, 0.03-0.159 Gy) and 0.05 Gy (range, 0.015-0.13 Gy), respectively. In the RANDO phantom, the median testicular doses with TLD and film dosimeter were 0.134 Gy (range 0.056-1.97 Gy) and 0.306 Gy (range, 0.065-2.25 Gy). Conclusions: Gonad doses are below sterility threshold in robotic SRS for different tumor localizations. However, particular attention should be given to gonads during robotic SRS for pelvic tumors.

  20. Stereotactic radiotherapy with real-time tumor tracking for non-small cell lung cancer: Clinical outcome

    International Nuclear Information System (INIS)

    Voort van Zyp, Noelle C. van der; Prevost, Jean-Briac; Hoogeman, Mischa S.; Praag, John; Holt, Bronno van der; Levendag, Peter C.; Klaveren, Robertus J. van; Pattynama, Peter; Nuyttens, Joost J.

    2009-01-01

    Purpose: To report the clinical outcome of treatment using real-time tumor tracking for 70 patients with inoperable stage I non-small cell lung cancer (NSCLC). Materials and methods: Seventy inoperable patients with peripherally located early-stage NSCLC were treated with 45 or 60 Gy in three fractions using CyberKnife. Pathology was available in 51% of patients. Thirty-nine patients had a T1-tumor and 31 had a T2-tumor. Markers were placed using the vascular, percutaneous intra-, or extra-pulmonary approach, depending on the risk of pneumothorax. Results: The actuarial 2-year local control rate for patients treated with 60 Gy was 96%, compared to 78% for patients treated with a total dose of 45 Gy (p = 0.197). All local recurrences (n = 4) occurred in patients with T2-tumors. Overall survival for the whole group at two years was 62% and the cause specific survival was 85%. The median follow-up was 15 months. Grade 3 toxicity occurred in two patients (3%) after marker placement. Treatment-related late grade 3 toxicity occurred in 7 patients (10%). No grade ≥4 toxicity occurred. Conclusion: Excellent local control of 96% at 1- and 2-years was achieved using 60 Gy in three fractions for NSCLC patients treated with the real-time tumor tracking. Toxicity was low.

  1. A prospective evaluation of patient-reported quality-of-life after (chemo)radiation for oropharyngeal cancer: Which patients are at risk of significant quality-of-life deterioration?

    International Nuclear Information System (INIS)

    Al-Mamgani, Abrahim; Rooij, Peter van; Tans, Lisa; Verduijn, Gerda M.; Sewnaik, Aniel; Jong, Rob J. Baatenburg de

    2013-01-01

    Background and purpose: To prospectively investigate the impact of different patients’ characteristics on quality-of-life (QoL) after (chemo)radiation for oropharyngeal cancer (OPC). Materials and methods: Between 2008 and 2011, 207 patients were treated with 46-Gy of (chemo)-IMRT followed by a boost by means of IMRT, brachytherapy (BT), or Cyberknife (CK). QoL-assessment was performed using the EORTC QLQ-C30, and QLQ-H and N35-questionnaires at baseline, end of treatment, 2, 4, 6 weeks and 3, 6, 12, and 18 months after treatment. The correlation between patients’ characteristics (AJCC-stage, tumor subsite, chemotherapy, neck dissection, unilateral neck irradiation, and boost technique), and changes in QoL over time were investigated. Results: At 18 months, improvements were seen in QLQ-C30 emotional functioning, insomnia, and pain and QLQ-H and N35 pain and speech. The scores on QLQ-H and N35 swallowing returned to baseline level while the scores on dry mouth, sticky saliva, opening mouth, and teeth were significantly deteriorated compared to baseline. Boost techniques and unilateral neck irradiation were significantly predictive for dry mouth, swallowing and opening mouth while chemotherapy was correlated with changes on swallowing and opening mouth scales. Conclusions: The most significant deterioration was seen in patient-related xerostomia. Boost technique, unilateral neck irradiation and chemotherapy were significantly predictive for QoL-changes over time

  2. Comparative Analysis of Neural Network Training Methods in Real-time Radiotherapy

    Directory of Open Access Journals (Sweden)

    Nouri S.

    2017-03-01

    Full Text Available Background: The motions of body and tumor in some regions such as chest during radiotherapy treatments are one of the major concerns protecting normal tissues against high doses. By using real-time radiotherapy technique, it is possible to increase the accuracy of delivered dose to the tumor region by means of tracing markers on the body of patients. Objective: This study evaluates the accuracy of some artificial intelligence methods including neural network and those of combination with genetic algorithm as well as particle swarm optimization (PSO estimating tumor positions in real-time radiotherapy. Method: One hundred recorded signals of three external markers were used as input data. The signals from 3 markers thorough 10 breathing cycles of a patient treated via a cyber-knife for a lung tumor were used as data input. Then, neural network method and its combination with genetic or PSO algorithms were applied determining the tumor locations using MATLAB© software program. Results: The accuracies were obtained 0.8%, 12% and 14% in neural network, genetic and particle swarm optimization algorithms, respectively. Conclusion: The internal target volume (ITV should be determined based on the applied neural network algorithm on training steps.

  3. Basic radiation oncology

    International Nuclear Information System (INIS)

    Beyzadeoglu, M. M.; Ebruli, C.

    2008-01-01

    Basic Radiation Oncology is an all-in-one book. It is an up-to-date bedside oriented book integrating the radiation physics, radiobiology and clinical radiation oncology. It includes the essentials of all aspects of radiation oncology with more than 300 practical illustrations, black and white and color figures. The layout and presentation is very practical and enriched with many pearl boxes. Key studies particularly randomized ones are also included at the end of each clinical chapter. Basic knowledge of all high-tech radiation teletherapy units such as tomotherapy, cyberknife, and proton therapy are also given. The first 2 sections review concepts that are crucial in radiation physics and radiobiology. The remaining 11 chapters describe treatment regimens for main cancer sites and tumor types. Basic Radiation Oncology will greatly help meeting the needs for a practical and bedside oriented oncology book for residents, fellows, and clinicians of Radiation, Medical and Surgical Oncology as well as medical students, physicians and medical physicists interested in Clinical Oncology. English Edition of the book Temel Radyasyon Onkolojisi is being published by Springer Heidelberg this year with updated 2009 AJCC Staging as Basic Radiation Oncology

  4. SU-C-BRB-04: Characteristics and Performance Evaluation of the First Commercial MLC for a Robotic Delivery System

    International Nuclear Information System (INIS)

    Fuerweger, C; Prins, P; Coskan, H; Heijmen, B

    2015-01-01

    Purpose: To assess characteristics and performance of the “Incise™” MLC (41 leaf pairs, 2.5mm width, FFF linac) mounted on the robotic SRS/SBRT platform “CyberKnife M6™” in a pre-clinical 5 months (11/2014–03/2015) test period. Methods: Beam properties were measured with unshielded diodes and EBT3 film. The CyberKnife workspace for MLC was analyzed by transforming robot node coordinates (cranial / body paths) into Euler geometry. Bayouth tests for leaf / bank position accuracy were performed in standard (A/P) and clinically relevant non-standard positions, before and after exercising the MLC for 10+ minutes. Total system and delivery accuracy were assessed in End-to-End tests and dosimetric verification of exemplary plans. Stability over time was evaluated in Picket-Fence-and adapted Winston-Lutz-tests (AQA) for different collimator angles. Results: Penumbrae (80–20%, with 100%=2*dose at inflection point; SAD 80cm; 10cm depth) parallel / perpendicular to leaf motion were 2.87/2.64mm for the smallest (0×76×0.75cm 2 ) and 5.34/4.94mm for the largest (9.76×9.75cm 2 ) square field. MLC circular field penumbrae exceeded fixed cones by 10–20% (e.g. 60mm: 4.0 vs. 3.6mm; 20mm: 3.6 vs. 2.9mm). Interleaf leakage was <0.5%. Clinically accessible workspace with MLC covered (non-coplanar) gantry angles of [-113°;+112°] (cranial) and [-108°;+102°] (body), and collimator angles of [-100°;+107°] (cranial) and [-91°;+100°] (body). Average leaf position offsets were ≤0.2mm in 14 standard A/P Bayouth tests and ≤0.6mm in 8 non-standard direction tests. Pre-test MLC exercise increased jaggedness (range ±0.3mm vs. ±0.5mm) and allowed to identify one malfunctioning leaf motor. Total system accuracy with MLC was 0.39±0.06mm in 6 End-to-End tests. Picket-Fence and AQA showed no adverse trends during the test period. Conclusion: The Incise™ MLC for CyberKnife M6™ displayed high accuracy and mechanical stability over the test period. The specific CyberKnife

  5. SU-C-BRB-04: Characteristics and Performance Evaluation of the First Commercial MLC for a Robotic Delivery System

    Energy Technology Data Exchange (ETDEWEB)

    Fuerweger, C [Erasmus MC Cancer Institute, Rotterdam (Netherlands); European Cyberknife Center Munich, Munich, DE (Germany); Prins, P; Coskan, H; Heijmen, B [Erasmus MC Cancer Institute, Rotterdam (Netherlands)

    2015-06-15

    Purpose: To assess characteristics and performance of the “Incise™” MLC (41 leaf pairs, 2.5mm width, FFF linac) mounted on the robotic SRS/SBRT platform “CyberKnife M6™” in a pre-clinical 5 months (11/2014–03/2015) test period. Methods: Beam properties were measured with unshielded diodes and EBT3 film. The CyberKnife workspace for MLC was analyzed by transforming robot node coordinates (cranial / body paths) into Euler geometry. Bayouth tests for leaf / bank position accuracy were performed in standard (A/P) and clinically relevant non-standard positions, before and after exercising the MLC for 10+ minutes. Total system and delivery accuracy were assessed in End-to-End tests and dosimetric verification of exemplary plans. Stability over time was evaluated in Picket-Fence-and adapted Winston-Lutz-tests (AQA) for different collimator angles. Results: Penumbrae (80–20%, with 100%=2*dose at inflection point; SAD 80cm; 10cm depth) parallel / perpendicular to leaf motion were 2.87/2.64mm for the smallest (0×76×0.75cm{sup 2}) and 5.34/4.94mm for the largest (9.76×9.75cm{sup 2}) square field. MLC circular field penumbrae exceeded fixed cones by 10–20% (e.g. 60mm: 4.0 vs. 3.6mm; 20mm: 3.6 vs. 2.9mm). Interleaf leakage was <0.5%. Clinically accessible workspace with MLC covered (non-coplanar) gantry angles of [-113°;+112°] (cranial) and [-108°;+102°] (body), and collimator angles of [-100°;+107°] (cranial) and [-91°;+100°] (body). Average leaf position offsets were ≤0.2mm in 14 standard A/P Bayouth tests and ≤0.6mm in 8 non-standard direction tests. Pre-test MLC exercise increased jaggedness (range ±0.3mm vs. ±0.5mm) and allowed to identify one malfunctioning leaf motor. Total system accuracy with MLC was 0.39±0.06mm in 6 End-to-End tests. Picket-Fence and AQA showed no adverse trends during the test period. Conclusion: The Incise™ MLC for CyberKnife M6™ displayed high accuracy and mechanical stability over the test period. The

  6. Stereotactic body radiation therapy for liver metastases from colorectal cancer: analysis of safety, feasibility, and early outcomes

    Directory of Open Access Journals (Sweden)

    Marie-Adele Sorel Kress

    2012-02-01

    Full Text Available Introduction: Colorectal cancer (CRC is the 3rd leading cause of cancer-related death in the U.S. Many patients with CRC develop hepatic metastases as the sole site of metastases. Historical treatment options were limited to resection or conventional radiation therapy. Stereotactic body radiation therapy (SBRT has emerged as a rational treatment approach. This study reviews our experience with SBRT for patients with liver metastases from CRC.Material and Methods: Fourteen histologically confirmed hepatic CRC metastases in 11 consecutive patients were identified between November, 2004 and June, 2009 at Georgetown University. All patients underwent CT-based treatment planning; a few also had MRI or PET/CT. All patients had fiducial markers placed under CT guidance and were treated using the CyberKnife system. Treatment response and toxicities were examined; survival and local control were evaluated.Results: Most patients were treated to a single hepatic lesion (n=8, with a few treated to 2 lesions (n=3. Median treatment volume was 99.7 cm3, and lesions were treated to a median BED10 of 49.7 Gy (range: 28 – 100.8 Gy. Median follow-up was 21 months; median survival was 16.1 months, with 2-year actuarial survival of 25.7%. One-year local control was 72%. Among patients with post-treatment imaging, 8 had stable disease (80% and 2 had progressive disease (20% at first follow-up. The most common grade 1-2 acute toxicities included nausea and alterations in liver function tests; there was one grade 3 toxicity (elevated bilirubin, and no grade 4-5 toxicities.Discussion: SBRT is safe and feasible for the treatment of limited hepatic metastases from CRC. Our results compare favorably with outcomes from previous studies of SBRT. Further studies are needed to better define patient eligibility, study the role of combined modality treatment, optimize treatment parameters, and characterize quality of life after treatment.

  7. The efficacy of stereotactic body radiation therapy on huge hepatocellular carcinoma unsuitable for other local modalities

    International Nuclear Information System (INIS)

    Que, Jenny Y; Lin, Li-Ching; Lin, Kuei-Li; Lin, Chia-Hui; Lin, Yu-Wei; Yang, Ching-Chieh

    2014-01-01

    To evaluate the safety and efficacy of Cyberknife stereotactic body radiation therapy (SBRT) and its effect on survival in patients with unresectable huge hepatocellular carcinoma (HCC) unsuitable of other standard treatment option. Between 2009 and 2011, 22 patients with unresectable huge HCC (≧10 cm) were treated with SBRT. dose ranged from 26 Gy to 40 Gy in five fractions. Overall survival (OS) and disease-progression free survival (DPFS) were determined by Kaplan-Meier analysis. Tumor response and toxicities were also assessed. After a median follow-up of 11.5 month (range 2–46 months). The objective response rate was achieved in 86.3% (complete response (CR): 22.7% and partial response (PR): 63.6%). The 1-yr. local control rate was 55.56%. The 1-year OS was 50% and median survival was 11 months (range 2–46 months). In univariate analysis, Child-Pugh stage (p = 0.0056) and SBRT dose (p = 0.0017) were significant factors for survival. However, in multivariate analysis, SBRT dose (p = 0.0072) was the most significant factor, while Child-Pugh stage of borderline significance. (p = 0.0514). Acute toxicities were mild and well tolerated. This study showed that SBRT can be delivered safely to huge HCC and achieved a substantial tumor regression and survival. The results suggest this technique should be considered a salvage treatment. However, local and regional recurrence remain the major cause of failure. Further studies of combination of SBRT and other treatment modalities may be reasonable

  8. SU-G-TeP4-12: Individual Beam QA for a Robotic Radiosurgery System Using a Scintillator Cone

    Energy Technology Data Exchange (ETDEWEB)

    McGuinness, C; Descovich, M; Sudhyadhom, A [University of California San Francisco, San Francisco, CA (United States)

    2016-06-15

    Purpose: The targeting accuracy of the Cyberknife system is measured by end-to-end tests delivering multiple isocentric beams to a point in space. While the targeting accuracy of two representative beams can be determined by a Winston-Lutz-type test, no test is available today to determine the targeting accuracy of each clinical beam. We used a scintillator cone to measure the accuracy of each individual beam. Methods: The XRV-124 from Logos Systems Int’l is a scintillator cone with an imaging system that is able to measure individual beam vectors and a resulting error between planned and measured beam coordinates. We measured the targeting accuracy of isocentric and non-isocentric beams for a number of test cases using the Iris and the fixed collimator. The average difference between plan and measured beam position was 0.8–1.2mm across the collimator sizes and plans considered here. The max error for a single beam was 2.5mm for the isocentric plans, and 1.67mm for the non-isocentric plans. The standard deviation of the differences was 0.5mm or less. Conclusion: The CyberKnife System is specified to have an overall targeting accuracy for static targets of less than 0.95mm. In E2E tests using the XRV124 system we measure average beam accuracy between 0.8 to 1.23mm, with maximum of 2.5mm. We plan to investigate correlations between beam position error and robot position, and to quantify the effect of beam position errors on patient specific plans. Martina Descovich has received research support and speaker honoraria from Accuray.

  9. Gemcitabine Chemotherapy and Single-Fraction Stereotactic Body Radiotherapy for Locally Advanced Pancreatic Cancer

    International Nuclear Information System (INIS)

    Schellenberg, Devin; Goodman, Karyn A.; Lee, Florence; Chang, Stephanie; Kuo, Timothy; Ford, James M.; Fisher, George A.; Quon, Andrew; Desser, Terry S.; Norton, Jeffrey; Greco, Ralph; Yang, George P.; Koong, Albert C.

    2008-01-01

    Purpose: Fractionated radiotherapy and chemotherapy for locally advanced pancreatic cancer achieves only modest local control. This prospective trial evaluated the efficacy of a single fraction of 25 Gy stereotactic body radiotherapy (SBRT) delivered between Cycle 1 and 2 of gemcitabine chemotherapy. Methods and Materials: A total of 16 patients with locally advanced, nonmetastatic, pancreatic adenocarcinoma received gemcitabine with SBRT delivered 2 weeks after completion of the first cycle. Gemcitabine was resumed 2 weeks after SBRT and was continued until progression or dose-limiting toxicity. The gross tumor volume, with a 2-3-mm margin, was treated in a single 25-Gy fraction by Cyberknife. Patients were evaluated at 4-6 weeks, 10-12 weeks, and every 3 months after SBRT. Results: All 16 patients completed SBRT. A median of four cycles (range one to nine) of chemotherapy was delivered. Three patients (19%) developed local disease progression at 14, 16, and 21 months after SBRT. The median survival was 11.4 months, with 50% of patients alive at 1 year. Patients with normal carbohydrate antigen (CA)19-9 levels either at diagnosis or after Cyberknife SBRT had longer survival (p <0.01). Acute gastrointestinal toxicity was mild, with 2 cases of Grade 2 (13%) and 1 of Grade 3 (6%) toxicity. Late gastrointestinal toxicity was more common, with five ulcers (Grade 2), one duodenal stenosis (Grade 3), and one duodenal perforation (Grade 4). A trend toward increased duodenal volumes radiated was observed in those experiencing late effects (p = 0.13). Conclusion: SBRT with gemcitabine resulted in comparable survival to conventional chemoradiotherapy and good local control. However, the rate of duodenal ulcer development was significant

  10. SU-G-TeP4-12: Individual Beam QA for a Robotic Radiosurgery System Using a Scintillator Cone

    International Nuclear Information System (INIS)

    McGuinness, C; Descovich, M; Sudhyadhom, A

    2016-01-01

    Purpose: The targeting accuracy of the Cyberknife system is measured by end-to-end tests delivering multiple isocentric beams to a point in space. While the targeting accuracy of two representative beams can be determined by a Winston-Lutz-type test, no test is available today to determine the targeting accuracy of each clinical beam. We used a scintillator cone to measure the accuracy of each individual beam. Methods: The XRV-124 from Logos Systems Int’l is a scintillator cone with an imaging system that is able to measure individual beam vectors and a resulting error between planned and measured beam coordinates. We measured the targeting accuracy of isocentric and non-isocentric beams for a number of test cases using the Iris and the fixed collimator. The average difference between plan and measured beam position was 0.8–1.2mm across the collimator sizes and plans considered here. The max error for a single beam was 2.5mm for the isocentric plans, and 1.67mm for the non-isocentric plans. The standard deviation of the differences was 0.5mm or less. Conclusion: The CyberKnife System is specified to have an overall targeting accuracy for static targets of less than 0.95mm. In E2E tests using the XRV124 system we measure average beam accuracy between 0.8 to 1.23mm, with maximum of 2.5mm. We plan to investigate correlations between beam position error and robot position, and to quantify the effect of beam position errors on patient specific plans. Martina Descovich has received research support and speaker honoraria from Accuray

  11. Statistical analysis of target motion in gated lung stereotactic body radiation therapy

    International Nuclear Information System (INIS)

    Zhao Bo; Yang Yong; Li Tianfang; Li Xiang; Heron, Dwight E; Huq, M Saiful

    2011-01-01

    An external surrogate-based respiratory gating technique is a useful method to reduce target margins for the treatment of a moving lung tumor. The success of this technique relies on a good correlation between the motion of the external markers and the internal tumor as well as the repeatability of the respiratory motion. In gated lung stereotactic body radiation therapy (SBRT), the treatment time for each fraction could exceed 30 min due to large fractional dose. Tumor motion may experience pattern changes such as baseline shift during such extended treatment time. The purpose of this study is to analyze tumor motion traces in actual treatment situations and to evaluate the effect of the target baseline shift in gated lung SBRT treatment. Real-time motion data for both the external markers and tumors from 51 lung SBRT treatments with Cyberknife Synchrony technology were analyzed in this study. The treatment time is typically greater than 30 min. The baseline shift was calculated with a rolling average window equivalent to ∼20 s and subtracted from that at the beginning. The magnitude of the baseline shift and its relationship with treatment time were investigated. Phase gating simulation was retrospectively performed on 12 carefully selected treatments with respiratory amplitude larger than 5 mm and regular phases. A customized gating window was defined for each individual treatment. It was found that the baseline shifts are specific to each patient and each fraction. Statistical analysis revealed that more than 69% treatments exhibited increased baseline shifts with the lapse of treatment time. The magnitude of the baseline shift could reach 5.3 mm during a 30 min treatment. Gating simulation showed that tumor excursion was caused mainly by the uncertainties in phase gating simulation and baseline shift, the latter being the primary factor. With a 5 mm gating window, 2 out of 12 treatments in the study group showed significant tumor excursion. Baseline shifts

  12. Isolated splenic metastasis from a thymic carcinoma: A case report.

    Science.gov (United States)

    Chen, Dongmei; Meng, Xiangying; Zhao, Yaowei; Wu, Shikai

    2016-09-01

    Thymic carcinomas are rare tumors that arise in the anterior mediastinum. Most of these malignancies develop local metastases limited in the thorax. Splenic metastases from thymic carcinomas are extremely rare. Here we report a case of isolated splenic metastasis from a 38-year-old female patient with Stage IV thymic carcinoma, who was treated with chemoradiotherapy. At twenty-2 months follow-up, the patient was found to have an isolated spleen metastasis, which was treated by Cyberknife with a reduced size of the metastasis, representing a partial response. Although splenic metastasis is a rare phenomenon, physicians need to be aware of the possibility of such metastases.

  13. Hypofractionated stereotactic irradiation. Basic and clinical researches

    International Nuclear Information System (INIS)

    Shibamoto, Yuta; Miyakawa, Akifumi; Iwata, Hiromitsu; Otsuka, Shinya; Ogino, Hiroyuki; Ayakawa, Shiho

    2011-01-01

    Hypofractionated stereotactic radiotherapy (SRT) has a number of biological advantages over single-session radiosurgery. An apparent trend is seen in the clinic towards shift from the latter to the former; however, there is no adequate model to convert single doses to hypofractionated doses. The linear-quadratic model overestimates the effect of single-fraction radiation. This should be kept in mind in evaluating the doses of stereotactic irradiation. ''Biological effective dose'' should not be used in radiosurgery and hypofractionated SRT. Clinically, we have used 3- to 10-fraction SRT for acoustic neuroma and benign skull base tumors using cyberknife and tomotherapy. Preliminary results are encouraging. (author)

  14. Cyst formation after radiosurgery for brain arteriovenous malformation treated with cystoperitoneal shunt

    International Nuclear Information System (INIS)

    Morihiro, Yusuke; Kato, Syoichi; Imoto, Hirochika

    2010-01-01

    Gamma knife and CyberKnife radiosurgery are well established and less invasive treatments for arteriovenous malformation. Delayed cyst formation is a rare but well-known complication of radiosurgery for arteriovenous malformations. The optimal treatment of cysts forming after radiosurgery remains debatable. We present a case of cyst formation after radiosurgery for brain arteriovenous malformation that was treated with a cystoperitoneal shunt (C-P shunt). A 36-year-old woman presented with left hemiparesis and numbness. Computed tomography (CT) revealed intracranial hemorrhage in the right basal ganglia. Digital subtraction angiography revealed arteriovenous malformation in the brain. Intravascular embolization was performed three times and radiosurgery was performed twice, whereby complete obliteration of the nidus was achieved. Six and a half years later, routine follow-up magnetic resonance imaging revealed cyst formation, and the patient gradually developed left hemiparesis. First, we performed stereotactic cyst aspiration. This initially resulted in a reduction in the size of the cyst and disappearance of left hemiparesis, but within a short time, the cyst increased in size again and there was recurrence of hemiparesis. Therefore, an Ommaya reservoir was established; aspiration of the cyst through this reservoir brought about an initial reduction in cyst size and alleviation of symptoms; however, no further reduction in cyst size or improvement in symptoms could be achieved. Twenty months after the placement of the Ommaya reservoir, we performed a C-P shunt operation. After the operation, further reduction in the cyst size and complete symptomatic recovery were observed. (author)

  15. Development of a real-time monitoring system for intra-fractional motion in intracranial treatment using pressure sensors.

    Science.gov (United States)

    Inata, Hiroki; Araki, Fujio; Kuribayashi, Yuta; Hamamoto, Yasushi; Nakayama, Shigeki; Sodeoka, Noritaka; Kiriyama, Tetsukazu; Nishizaki, Osamu

    2015-09-21

    This study developed a dedicated real-time monitoring system to detect intra-fractional head motion in intracranial radiotherapy using pressure sensors. The dedicated real-time monitoring system consists of pressure sensors with a thickness of 0.6 mm and a radius of 9.1 mm, a thermoplastic mask, a vacuum pillow, and a baseplate. The four sensors were positioned at superior-inferior and right-left sides under the occipital area. The sampling rate of pressure sensors was set to 5 Hz. First, we confirmed that the relationship between the force and the displacement of the vacuum pillow follows Hook's law. Next, the spring constant for the vacuum pillow was determined from the relationship between the force given to the vacuum pillow and the displacement of the head, detected by Cyberknife target locating system (TLS) acquisitions in clinical application. Finally, the accuracy of our system was evaluated by using the 2  ×  2 confusion matrix. The regression lines between the force, y, and the displacement, x, of the vacuum pillow were given by y = 3.8x, y = 4.4x, and y = 5.0x when the degree of inner pressure was  -12 kPa,-20 kPa, and  -27 kPa, respectively. The spring constant of the vacuum pillow was 1.6 N mm(-1) from the 6D positioning data of a total of 2999 TLS acquisitions in 19 patients. Head motions of 1 mm, 1.5 mm, and 2 mm were detected in real-time with the accuracies of 67%, 84%, and 89%, respectively. Our system can detect displacement of the head continuously during every interval of TLS with a resolution of 1-2 mm without any radiation exposure.

  16. Virtual HDR CyberKnife SBRT for Localized Prostatic Carcinoma: 5-year Disease-free Survival and Toxicity Observations

    Directory of Open Access Journals (Sweden)

    Donald Blake Fuller

    2014-11-01

    Full Text Available PURPOSEProstate stereotactic body radiotherapy (SBRT may substantially recapitulate the dose distribution of high-dose-rate (HDR brachytherapy, representing an externally delivered Virtual HDR treatment method. Herein we present 5-year outcomes from a cohort of consecutively treated Virtual HDR SBRT prostate cancer patients.METHODSSeventy-nine patients were treated from 2006 - 2009, 40 low-risk and 39 intermediate-risk, under IRB-approved clinical trial, to 38 Gy in 4 fractions. The planning target volume (PTV included prostate plus a 2-mm volume expansion in all directions, with selective use of a 5-mm prostate-to-PTV expansion and proximal seminal vesicle coverage in intermediate-risk patients, to better cover potential extraprostatic disease; rectal PTV margin reduced to zero in all cases. The prescription dose covered > 95% of the PTV (V100 >= 95%, with a minimum 150% PTV dose escalation to create HDR-like PTV dose distribution.RESULTSMedian pre-SBRT PSA level of 5.6 ng/mL decreased to 0.05 ng/mL 5 years out and 0.02 ng/mL 6 years out. At least one PSA bounce was seen in 55 patients (70% but only 3 of them subsequently relapsed, Biochemical-relapse-free survival was 100% and 92% for low-risk and intermediate-risk patients, respectively, by ASTRO definition (98% and 92% by Phoenix definition. Local relapse did not occur, distant metastasis-free survival was 100% and 95% by risk-group, and disease-specific survival was 100%. Acute and late grade 2 GU toxicity incidence was 10% and 9%, respectively; with 6% late grade 3 GU toxicity. Acute urinary retention did not occur. Acute and late grade 2 GI toxicity was 0% and 1%, respectively, with no grade 3 or higher toxicity. Of patients potent pre-SBRT, 65% remained so at 5 years.CONCLUSIONSVirtual HDR prostate SBRT creates a very low PSA nadir, a high rate of 5-year disease-free survival and an acceptable toxicity incidence, with results closely resembling those reported post-HDR brachytherapy.

  17. Atlas-based functional radiosurgery: Early results

    Energy Technology Data Exchange (ETDEWEB)

    Stancanello, J.; Romanelli, P.; Pantelis, E.; Sebastiano, F.; Modugno, N. [Politecnico di Milano, Bioengineering Department and NEARlab, Milano, 20133 (Italy) and Siemens AG, Research and Clinical Collaborations, Erlangen, 91052 (Germany); Functional Neurosurgery Deptartment, Neuromed IRCCS, Pozzilli, 86077 (Italy); CyberKnife Center, Iatropolis, Athens, 15231 (Greece); Functional Neurosurgery Deptartment, Neuromed IRCCS, Pozzilli, 86077 (Italy)

    2009-02-15

    Functional disorders of the brain, such as dystonia and neuropathic pain, may respond poorly to medical therapy. Deep brain stimulation (DBS) of the globus pallidus pars interna (GPi) and the centromedian nucleus of the thalamus (CMN) may alleviate dystonia and neuropathic pain, respectively. A noninvasive alternative to DBS is radiosurgical ablation [internal pallidotomy (IP) and medial thalamotomy (MT)]. The main technical limitation of radiosurgery is that targets are selected only on the basis of MRI anatomy, without electrophysiological confirmation. This means that, to be feasible, image-based targeting must be highly accurate and reproducible. Here, we report on the feasibility of an atlas-based approach to targeting for functional radiosurgery. In this method, masks of the GPi, CMN, and medio-dorsal nucleus were nonrigidly registered to patients' T1-weighted MRI (T1w-MRI) and superimposed on patients' T2-weighted MRI (T2w-MRI). Radiosurgical targets were identified on the T2w-MRI registered to the planning CT by an expert functional neurosurgeon. To assess its feasibility, two patients were treated with the CyberKnife using this method of targeting; a patient with dystonia received an IP (120 Gy prescribed to the 65% isodose) and a patient with neuropathic pain received a MT (120 Gy to the 77% isodose). Six months after treatment, T2w-MRIs and contrast-enhanced T1w-MRIs showed edematous regions around the lesions; target placements were reevaluated by DW-MRIs. At 12 months post-treatment steroids for radiation-induced edema and medications for dystonia and neuropathic pain were suppressed. Both patients experienced significant relief from pain and dystonia-related problems. Fifteen months after treatment edema had disappeared. Thus, this work shows promising feasibility of atlas-based functional radiosurgery to improve patient condition. Further investigations are indicated for optimizing treatment dose.

  18. The effect of metallic implants on radiation therapy in spinal tumor patients with metallic spinal implants.

    Science.gov (United States)

    Son, Seok Hyun; Kang, Young Nam; Ryu, Mi-Ryeong

    2012-01-01

    The aim of this study was to evaluate the effect of metallic implants on the dose calculation for radiation therapy in patients with metallic implants and to find a way to reduce the error of dose calculation. We made a phantom in which titanium implants were inserted into positions similar to the implant positions in spinal posterior/posterolateral fusion. We compared the calculated dose of the treatment planning systems with the measured dose in the treatment equipment. We used 3 kinds of computed tomography (CT) (kilovoltage CT, extended-scaled kilovoltage CT, and megavoltage CT) and 3 kinds of treatment equipment (ARTISTE, TomoTherapy Hi-Art, and Cyberknife). For measurement of doses, we used an ionization chamber and Gafchromic external beam therapy film. The absolute doses that were measured using an ionization chamber at the isocenter in the titanium phantom were on average 1.9% lower than those in the reference phantom (p = 0.002). There was no statistically significant difference according to the kinds of CT images, the treatment equipment, and the size of the targets. As the distance from the surface of the titanium implants became closer, the measured doses tended to decrease (p metallic implants was less in the megavoltage CT than in the kilovoltage CT or the extended-scaled kilovoltage CT. The error caused by the titanium implants was beyond a clinically acceptable range. To reduce the error of dose calculation, we suggest that the megavoltage CT be used for planning. In addition, it is necessary to consider the distance between the titanium implants and the targets or the organs at risk to prescribe the dose for the target and the dose constraint for the organs at risk. Copyright © 2012 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  19. Doses to organs at cerebral risks: optimization by robotized stereotaxic radiotherapy and automatic segmentation atlas versus three dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Bondiau, P.Y.; Thariat, J.; Benezery, K.; Herault, J.; Dalmasso, C.; Marcie, S.; Malandain, G.

    2007-01-01

    The stereotaxic radiotherapy robotized by 'Cyberknife fourth generation' allows a dosimetric optimization with a high conformity index on the tumor and radiation doses limited on organs at risk. A cerebral automatic anatomic segmentation atlas of organs at risk are used in routine in three dimensions. This study evaluated the superiority of the stereotaxic radiotherapy in comparison with the three dimensional conformal radiotherapy on the preservation of organs at risk in regard of the delivered dose to tumors justifying an accelerated hypo fractionation and a dose escalation. This automatic segmentation atlas should allow to establish correlations between anatomy and cerebral dosimetry; This atlas allows to underline the dosimetry optimization by stereotaxic radiotherapy robotized for organs at risk. (N.C.)

  20. Stereotactic body radiotherapy for primary prostate cancer: a systematic review

    International Nuclear Information System (INIS)

    Tan, Tze-Jian; Foroudi, Farsgad; Gill, Suki; Siva, Shankar

    2014-01-01

    Stereotactic body radiotherapy (SBRT) for prostate cancer allows overall treatment times to be reduced to as little as 1 week while maintaining a non-invasive approach. This study provides a comprehensive summary of the literature relating to SBRT in prostate cancer. A systematic review of the relevant literature was performed using structured search terms. Fourteen phase I–II trials and retrospective studies using SBRT for the treatment of prostate cancer were used. Three studies were identified which addressed cost. Dose fractionation, radiotherapy procedures, biochemical progression-free survival, toxicity, cost and quality of life were critically appraised. A total of 1472 patients were examined across studies. Median follow-up ranged from 11 to 60 months. The most common dose fractionation was 35–36.25Gy in five fractions, used in nine out of 14 studies. Ten of 14 studies used CyberKnife. The overall biochemical progression-free survival ranged 81–100%. Acute grade 2 urinary and rectal toxicities were reported in 5–42% and 0–27% of patients, respectively. Acute grade 3 or more urinary and rectal toxicity were 0.5% and 0%, respectively. Late grade 2 urinary toxicity was reported in 0–29% of patients, while 1.3% had a late grade 3 urinary toxicity. There were no late grade 4 urinary toxicities seen. Late grade 2 rectal toxicity was reported in 0–11%, while 0.5% had a late grade 3 rectal toxicity. Late grade 4 rectal toxicity was reported in 0.2% of patients.

  1. Current status of the infrastructure and characteristics of radiation oncology in Korea

    International Nuclear Information System (INIS)

    Huh, Seung Jae

    2007-01-01

    An analysis of radiotherapy infrastructure in Korea was performed in 2006 to collect data on treatment devices, the work force and new patients for future development plans. The survey included radiotherapy centers, their major equipment and personnel. The centers were categorized into four levels: level 0 (stand-alone teletherapy units); level 1 (teletherapy, brachytherapy, treatment planning system, and at least the part-time service of a medical physicist); level 2 (level 1 plus individual customized radiotherapy block and full-time medical physicist); and level 3 [level 2 plus intensity-modulated radiation therapy (IMRT), intra-operative radiation therapy or stereotactic radiotherapy]. A total of 61 facilities delivered radiation therapy with 104 megavoltage devices, which included 96 linear accelerators, two cobalt 60 units, three Tomotherapy, two CyberKnife units and one proton accelerator. There were 28789 new radiotherapy patients in 2004. Personnel included 132 radiation oncologists, 50 radiation oncology residents, 64 physicists, 130 nurses and 369 radiation therapy technologists. Thirty-two percent (20 facilities) used a CT-simulator, 66% (40) used a positron emission tomography (PET) or PET-CT scanner, and 35% (22) had the capacity to implement IMRT. Centers were also divided into four levels: 41% were included in level 3, 31% in level 2, 25% in level 1 and 3% in level 0. There is a shortage of human resources. The distribution of megavoltage units per million inhabitants over the country was inadequate; geographic disparities were noted. Furthermore, the necessity of quality assurance for recent high-technology radiation therapy is increasing. (author)

  2. Personality does not predict treatment preference, treatment experience does: a study of four complementary pain treatments.

    Science.gov (United States)

    Blasche, Gerhard; Melchart, Herbert; Leitner, Daniela; Marktl, Wolfgang

    2007-10-01

    The aim of the present study was to determine the extent to which personality and treatment experience affect patients' appraisals of 4 complementary treatments for chronic pain. A total of 232 chronic pain patients (164 females, 68 males, average age 56.6 years) visiting a spa clinic in Austria returned a questionnaire on patient characteristics and personality (autonomy, depressiveness, assertiveness, self-control) as well as attitudes towards (i.e. appealing, effective, pleasant) and experience of the treatments. Results were analysed by use of linear regression analysis and confidence intervals. Although all treatments were appraised positively, the passive treatments (thermal water tub baths, classical massage) were favoured more than the active treatments (relaxation training or exercise therapy). Treatment appraisal was not predicted by any of the personality traits but to a large extent by treatment experience. Relaxing, not unpleasant treatments were the most highly esteemed treatments. How strenuous or tiring a treatment was only had a minor effect on its appraisal. Neither do dependent, passive patients prefer passive treatments, nor do conscientious patients prefer active treatments. Instead, the appraisal of treatments that induce specific somatosensory sensations is largely determined by treatment experiences, i.e. what the treatment feels like. Despite the popularity of CAM which encompasses many experientially intensive treatments, treatment experience has to date been a neglected topic of treatment research.

  3. Cholera Treatment

    Science.gov (United States)

    ... Diagnosis and Detection Laboratory Testing for Cholera Treatment Rehydration Therapy Antibiotic Treatment Zinc Treatment Prevention & Control Five ... page for current cholera treatment recommendations. Cholera Treatments Rehydration therapy , meaning prompt restoration of lost fluids and ...

  4. A feasibility dosimetric study on prostate cancer. Are we ready for a multicenter clinical trial on SBRT?

    Energy Technology Data Exchange (ETDEWEB)

    Marino, Carmelo; Bonanno, Elisa [Humanitas C.C.O., Catania (Italy); Villaggi, Elena [AUSL, Piacenza (Italy); Maggi, Giulia; Mancosu, Pietro [IRCCS Humanitas Clinical Research Center, Milan (Italy); Esposito, Marco [Azienda Sanitaria Firenze (Italy); Strigari, Lidia [Regina Elena National Cancer Institute, Rome (Italy). Lab. of Medical Physics and Expert Systems; Borzi, Giusi R. [REM Radioterapia, Catania (Italy); Carbonini, Claudia [A.O. Ospedale Niguarda Ca' Granda, Milan (Italy); Consorti, Rita [ACO S. Filippo Neri, Rome (Italy); Fedele, David [Casa di Cura Privata San Rossore s.r.l., Pisa (Italy); Fiandra, Christian [Torino Univ. (Italy). Radiation Oncology Unit; Ielo, Isidora [A.O.U. Policlinico G. Martino, Messina (Italy); Malatesta, Tiziana [' ' S. Giovanni Calibita' ' Fatebenefratelli, Rome (Italy); Malisan, Maria Rosa [Azienda Ospedaliero-Universitaria di Udine (Italy); Martinotti, Anna [Centro Diagnostico Italiano, Milan (Italy); Moretti, Renzo [Az. Ospedaliera Spedali Civili di Brescia (Italy); Nardiello, Barbara [UPMC San Pietro FBF, Rome (Italy); Oliviero, Caterina; Clemente, Stefania [IRCCS CROB Rieonero in Vulture, Potenza (Italy)

    2015-07-15

    The Italian Association of Medical Physics (AIFM) started a working group dedicated to stereotactic body radiotherapy (SBRT) treatment. In this work, we performed a multicenter planning study on patients who were candidates for SBRT in the treatment of prostate cancer with the aim of evaluating the dosimetric consistency among the different hospitals. Fourteen centers were provided the contours of 5 patients. Plans were performed following the dose prescription and constraints for organs at risk (OARs) of a reference paper. The dose prescription was 35 Gy in five fractions for the planning target volume (PTV). Different techniques were used (3D-CRT, fixed-Field IMRT, VMAT, CyberKnife). Plans were compared in terms of dose-volume histogram (DVH) parameters. Furthermore, the median DVH was calculated and one patient was re-planned. A total of 70 plans were compared. The maximum dose to the body was 107.9 ± 4.5 % (range 101.5-116.3 %). Dose at 98 % (D{sub 98} {sub %}) and mean dose to the clinical target volume (CTV) were 102.0 ± 0.9 % (global range 101.1-102.9 %) and 105.1 ± 0.6 % (range 98.6-124.6 %). Similar trends were found for D{sub 95} {sub %} and mean dose to the PTV. Important differences were found in terms of the homogeneity index. Doses to OARs were heterogeneous. The subgroups with the same treatment planning system showed differences comparable to the differences of the whole group. In the re-optimized plans, DVH differences among institutes were reduced and OAR sparing improved. Important dosimetric differences with possible clinical implications, in particular related to OARs, were found. Replanning allowed a reduction in the OAR dose and decreased standard deviations. Multicenter clinical trials on SBRT should require a preplanning study to standardize the optimization procedure. (orig.) [German] Der italienische Verband der Medizinphysiker (AIFM) hat eine Arbeitsgruppe gegruendet, die sich mit der Koerperstammstereotaxie (SBRT) befasst. Im Rahmen

  5. SU-E-T-59: Calculations of Collimator Scatter Factors (Sc) with and Without Custom-Made Build-Up Caps for CyberKnife

    Energy Technology Data Exchange (ETDEWEB)

    Wokoma, S; Yoon, J; Jung, J [East Carolina University, Greenville, NC (United States); Lee, S [Rhode Island Hospital / Warren Alpert Medical, Providence, RI (United States)

    2014-06-01

    Purpose: To investigate the impact of custom-made build-up caps for a diode detector in robotic radiosurgery radiation fields with variable collimator (IRIS) for collimator scatter factor (Sc) calculation. Methods: An acrylic cap was custom-made to fit our SFD (IBA Dosimetry, Germany) diode detector. The cap has thickness of 5 cm, corresponding to a depth beyond electron contamination. IAEA phase space data was used for beam modeling and DOSRZnrc code was used to model the detector. The detector was positioned at 80 cm source-to-detector distance. Calculations were performed with the SFD, with and without the build-up cap, for clinical IRIS settings ranging from 7.5 to 60 mm. Results: The collimator scatter factors were calculated with and without 5 cm build-up cap. They were agreed within 3% difference except 15 mm cone. The Sc factor for 15 mm cone without buildup was 13.2% lower than that with buildup. Conclusion: Sc data is a critical component in advanced algorithms for treatment planning in order to calculate the dose accurately. After incorporating build-up cap, we discovered differences of up to 13.2 % in Sc factors in the SFD detector, when compared against in-air measurements without build-up caps.

  6. Treatment goals and treatment in exercise therapy.

    NARCIS (Netherlands)

    Zuijderduin, W.M.; Dekker, J.

    1994-01-01

    In the present study a quantitative description is given of treatment in exercise therapy according to Cesar and according to Mensendieck. Information was gathered from saurvey on exercise therapy in the Netherlands. Characteristics of treatment are described including treatment goals, emphasis of

  7. Treatment diary for botulinum toxin spasticity treatment

    DEFF Research Database (Denmark)

    Biering-Sørensen, Bo; Iversen, Helle K; Frederiksen, Inge M S

    2017-01-01

    The aim of this study is to develop a treatment diary for patients receiving spasticity treatment including botulinum toxin injection and physiotherapy and/or occupational therapy. The diary focuses on problems triggered by skeletal muscle overactivity; agreed goals for treatment and the patient...

  8. 40 CFR 133.105 - Treatment equivalent to secondary treatment.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 21 2010-07-01 2010-07-01 false Treatment equivalent to secondary treatment. 133.105 Section 133.105 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS SECONDARY TREATMENT REGULATION § 133.105 Treatment equivalent to secondary treatment...

  9. Treatment-refractory anxiety; definition, risk factors, and treatment challenges.

    Science.gov (United States)

    Roy-Byrne, Peter

    2015-06-01

    A sizable proportion of psychiatric patients will seek clinical evaluation and treatment for anxiety symptoms reportedly refractory to treatment. This apparent lack of response is either due to "pseudo-resistance" (a failure to have received and adhered to a recognized and effective treatment or treatments for their condition) or to true "treatment resistance." Pseudo-resistance can be due to clinician errors in selecting and delivering an appropriate treatment effectively, or to patient nonadherence to a course of treatment. True treatment resistance can be due to unrecognized exogenous anxiogenic factors (eg, caffeine overuse, sleep deprivation, use of alcohol or marijuana) or an incorrect diagnosis (eg, atypical bipolar illness, occult substance abuse, attention deficit-hyperactivity disorder). Once the above factors are eliminated, treatment should focus on combining effective medications and cognitive behavioral therapy, combining several medications (augmentation), or employing novel medications or psychotherapies not typically indicated as first-line evidence-based anxiety treatments.

  10. Treatment-refractory anxiety; definition, risk factors, and treatment challenges

    Science.gov (United States)

    Roy-Byrne, Peter

    2015-01-01

    A sizable proportion of psychiatric patients will seek clinical evaluation and treatment for anxiety symptoms reportedly refractory to treatment. This apparent lack of response is either due to “pseudo-resistance” (a failure to have received and adhered to a recognized and effective treatment or treatments for their condition) or to true “treatment resistance.” Pseudo-resistance can be due to clinician errors in selecting and delivering an appropriate treatment effectively, or to patient nonadherence to a course of treatment. True treatment resistance can be due to unrecognized exogenous anxiogenic factors (eg, caffeine overuse, sleep deprivation, use of alcohol or marijuana) or an incorrect diagnosis (eg, atypical bipolar illness, occult substance abuse, attention deficit-hyperactivity disorder). Once the above factors are eliminated, treatment should focus on combining effective medications and cognitive behavioral therapy, combining several medications (augmentation), or employing novel medications or psychotherapies not typically indicated as first-line evidence-based anxiety treatments. PMID:26246793

  11. Is the PTW 60019 microDiamond a suitable candidate for small field reference dosimetry?

    Science.gov (United States)

    De Coste, Vanessa; Francescon, Paolo; Marinelli, Marco; Masi, Laura; Paganini, Lucia; Pimpinella, Maria; Prestopino, Giuseppe; Russo, Serenella; Stravato, Antonella; Verona, Claudio; Verona-Rinati, Gianluca

    2017-09-01

    A systematic study of the PTW microDiamond (MD) output factors (OF) is reported, aimed at clarifying its response in small fields and investigating its suitability for small field reference dosimetry. Ten MDs were calibrated under 60Co irradiation. OF measurements were performed in 6 MV photon beams by a CyberKnife M6, a Varian DHX and an Elekta Synergy linacs. Two PTW silicon diodes E (Si-D) were used for comparison. The results obtained by the MDs were evaluated in terms of absorbed dose to water determination in reference conditions and OF measurements, and compared to the results reported in the recent literature. To this purpose, the Monte Carlo (MC) beam-quality correction factor, kQMD , was calculated for the MD, and the small field output correction factors, k{{Qclin},{{Q}msr}}{{fclin},{{f}msr}} , were calculated for both the MD and the Si-D by two different research groups. An empirical function was also derived, providing output correction factors within 0.5% from the MC values calculated for all of the three linacs. A high reproducibility of the dosimetric properties was observed among the ten MDs. The experimental kQMD values are in agreement within 1% with the MC calculated ones. Output correction factors within  +0.7% and  -1.4% were obtained down to field sizes as narrow as 5 mm. The resulting MD and Si-D field factors are in agreement within 0.2% in the case of CyberKnife measurements and 1.6% in the other cases. This latter higher spread of the data was demonstrated to be due to a lower reproducibility of small beam sizes defined by jaws or multi leaf collimators. The results of the present study demonstrate the reproducibility of the MD response and provide a validation of the MC modelling of this device. In principle, accurate reference dosimetry is thus feasible by using the microDiamond dosimeter for field sizes down to 5 mm.

  12. Incontinence Treatment: Biofeedback

    Science.gov (United States)

    ... Treatment Lifestyle Changes Dietary Tips Medication Bowel Management Biofeedback Surgical Treatments Newer Treatment Options Tips on Finding ... Treatment Lifestyle Changes Dietary Tips Medication Bowel Management Biofeedback Surgical Treatments Newer Treatment Options Tips on Finding ...

  13. Treatment Effects

    DEFF Research Database (Denmark)

    Heckman, James J.; Lopes, Hedibert F.; Piatek, Rémi

    2014-01-01

    This paper contributes to the emerging Bayesian literature on treatment effects. It derives treatment parameters in the framework of a potential outcomes model with a treatment choice equation, where the correlation between the unobservable components of the model is driven by a low-dimensional v......This paper contributes to the emerging Bayesian literature on treatment effects. It derives treatment parameters in the framework of a potential outcomes model with a treatment choice equation, where the correlation between the unobservable components of the model is driven by a low...... to observe the same person in both the treated and untreated states, but it also turns out to be straightforward to implement. Formulae are provided to compute mean treatment effects as well as their distributional versions. A Monte Carlo simulation study is carried out to illustrate how the methodology can...

  14. EDITORIAL: Special section: Selected papers from the Third European Workshop on Monte Carlo Treatment Planning (MCTP2012) Special section: Selected papers from the Third European Workshop on Monte Carlo Treatment Planning (MCTP2012)

    Science.gov (United States)

    Spezi, Emiliano; Leal, Antonio

    2013-04-01

    ) investigated the recombination effect on liquid ionization chambers for stereotactic radiotherapy, a field of increasing importance in external beam radiotherapy. They modelled both radiation source (Cyberknife unit) and detector with the BEAMnrc/EGSnrc codes and quantified the dependence of the response of this type of detectors on factors such as the volume effect and the electrode. They also recommended that these dependences be accounted for in measurements involving small fields. In the field of external beam radiotherapy, Chakarova et al (2013) showed how total body irradiation (TBI) could be improved by simulating patient treatments with MC. In particular, BEAMnrc/EGSnrc based simulations highlighted the importance of optimizing individual compensators for TBI treatments. In the same area of application, Mairani et al (2013) reported on a new tool for treatment planning in proton therapy based on the FLUKA MC code. The software, used to model both proton therapy beam and patient anatomy, supports single-field and multiple-field optimization and can be used to optimize physical and relative biological effectiveness (RBE)-weighted dose distribution, using both constant and variable RBE models. In the field of nuclear medicine Marcatili et al (2013) presented RAYDOSE, a Geant4-based code specifically developed for applications in molecular radiotherapy (MRT). RAYDOSE has been designed to work in MRT trials using sequential positron emission tomography (PET) or single-photon emission tomography (SPECT) imaging to model patient specific time-dependent metabolic uptake and to calculate the total 3D dose distribution. The code was validated through experimental measurements in homogeneous and heterogeneous phantoms. Finally, in the field of code development Miras et al (2013) reported on CloudMC, a Windows Azure-based application for the parallelization of MC calculations in a dynamic cluster environment. Although the performance of CloudMC has been tested with the PENELOPE MC

  15. A singular value decomposition linear programming (SVDLP) optimization technique for circular cone based robotic radiotherapy

    Science.gov (United States)

    Liang, Bin; Li, Yongbao; Wei, Ran; Guo, Bin; Xu, Xuang; Liu, Bo; Li, Jiafeng; Wu, Qiuwen; Zhou, Fugen

    2018-01-01

    With robot-controlled linac positioning, robotic radiotherapy systems such as CyberKnife significantly increase freedom of radiation beam placement, but also impose more challenges on treatment plan optimization. The resampling mechanism in the vendor-supplied treatment planning system (MultiPlan) cannot fully explore the increased beam direction search space. Besides, a sparse treatment plan (using fewer beams) is desired to improve treatment efficiency. This study proposes a singular value decomposition linear programming (SVDLP) optimization technique for circular collimator based robotic radiotherapy. The SVDLP approach initializes the input beams by simulating the process of covering the entire target volume with equivalent beam tapers. The requirements on dosimetry distribution are modeled as hard and soft constraints, and the sparsity of the treatment plan is achieved by compressive sensing. The proposed linear programming (LP) model optimizes beam weights by minimizing the deviation of soft constraints subject to hard constraints, with a constraint on the l 1 norm of the beam weight. A singular value decomposition (SVD) based acceleration technique was developed for the LP model. Based on the degeneracy of the influence matrix, the model is first compressed into lower dimension for optimization, and then back-projected to reconstruct the beam weight. After beam weight optimization, the number of beams is reduced by removing the beams with low weight, and optimizing the weights of the remaining beams using the same model. This beam reduction technique is further validated by a mixed integer programming (MIP) model. The SVDLP approach was tested on a lung case. The results demonstrate that the SVD acceleration technique speeds up the optimization by a factor of 4.8. Furthermore, the beam reduction achieves a similar plan quality to the globally optimal plan obtained by the MIP model, but is one to two orders of magnitude faster. Furthermore, the SVDLP

  16. A singular value decomposition linear programming (SVDLP) optimization technique for circular cone based robotic radiotherapy.

    Science.gov (United States)

    Liang, Bin; Li, Yongbao; Wei, Ran; Guo, Bin; Xu, Xuang; Liu, Bo; Li, Jiafeng; Wu, Qiuwen; Zhou, Fugen

    2018-01-05

    With robot-controlled linac positioning, robotic radiotherapy systems such as CyberKnife significantly increase freedom of radiation beam placement, but also impose more challenges on treatment plan optimization. The resampling mechanism in the vendor-supplied treatment planning system (MultiPlan) cannot fully explore the increased beam direction search space. Besides, a sparse treatment plan (using fewer beams) is desired to improve treatment efficiency. This study proposes a singular value decomposition linear programming (SVDLP) optimization technique for circular collimator based robotic radiotherapy. The SVDLP approach initializes the input beams by simulating the process of covering the entire target volume with equivalent beam tapers. The requirements on dosimetry distribution are modeled as hard and soft constraints, and the sparsity of the treatment plan is achieved by compressive sensing. The proposed linear programming (LP) model optimizes beam weights by minimizing the deviation of soft constraints subject to hard constraints, with a constraint on the l 1 norm of the beam weight. A singular value decomposition (SVD) based acceleration technique was developed for the LP model. Based on the degeneracy of the influence matrix, the model is first compressed into lower dimension for optimization, and then back-projected to reconstruct the beam weight. After beam weight optimization, the number of beams is reduced by removing the beams with low weight, and optimizing the weights of the remaining beams using the same model. This beam reduction technique is further validated by a mixed integer programming (MIP) model. The SVDLP approach was tested on a lung case. The results demonstrate that the SVD acceleration technique speeds up the optimization by a factor of 4.8. Furthermore, the beam reduction achieves a similar plan quality to the globally optimal plan obtained by the MIP model, but is one to two orders of magnitude faster. Furthermore, the SVDLP

  17. Estimate of the real-time respiratory simulation system in cyberknife image-guided radiosurgery

    International Nuclear Information System (INIS)

    Min, Chul Kee; Chung, Weon Kuu; Lee, Suk

    2010-01-01

    The purpose of this study was to evaluate the target accuracy according to the movement with respiration of an actual patient in a quantitative way by developing a real-time respiratory simulation system (RRSS), including a patient customized 3D moving phantom. The real-time respiratory simulation system (RRSS) consists of two robots in order to implement both the movement of body surfaces and the movement of internal organs caused by respiration. The quantitative evaluation for the 3D movement of the RRSS was performed using a real-time laser displacement sensor for each axis. The average difference in the static movement of the RRSS was about 0.01 ∼ 0.06 mm. Also, in the evaluation of the dynamic movement by producing a formalized sine wave with the phase of four seconds per cycle, the difference between the measured and the calculated values for each cycle length in the robot that was in charge of body surfaces and the robot that was in charge of the movement of internal tumors showed 0.10 ∼ 0.55 seconds, and the correlation coefficients between the calculated and the measured values were 0.998 ∼ 0.999. The differences between the maximum and the minimum amplitudes were 0.01 ∼ 0.06 mm, and the reproducibility was within ±0.5 mm. In the case of the application and non-application of respiration, the target errors were -0.05 ∼ 1.05 mm and -0.13 ∼ 0.74 mm, respectively, and the entire target errors were 1.30 mm and 0.79 mm, respectively. Based on the accuracy in the RRSS system, various respiration patterns of patients can be reproduced in real-time. Also, this system can be used as an optimal tool for applying patient customized accuracy management in image-guided radiosurgery.

  18. Estimate of the real-time respiratory simulation system in cyberknife image-guided radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Min, Chul Kee [Konyang Univ. Hospital, Daejeon (Korea, Republic of); Kyonggi University, Seoul (Korea, Republic of); Chung, Weon Kuu [Konyang Univ. Hospital, Daejeon (Korea, Republic of); Lee, Suk [Korea University, Seoul (Korea, Republic of); and others

    2010-01-15

    The purpose of this study was to evaluate the target accuracy according to the movement with respiration of an actual patient in a quantitative way by developing a real-time respiratory simulation system (RRSS), including a patient customized 3D moving phantom. The real-time respiratory simulation system (RRSS) consists of two robots in order to implement both the movement of body surfaces and the movement of internal organs caused by respiration. The quantitative evaluation for the 3D movement of the RRSS was performed using a real-time laser displacement sensor for each axis. The average difference in the static movement of the RRSS was about 0.01 {approx} 0.06 mm. Also, in the evaluation of the dynamic movement by producing a formalized sine wave with the phase of four seconds per cycle, the difference between the measured and the calculated values for each cycle length in the robot that was in charge of body surfaces and the robot that was in charge of the movement of internal tumors showed 0.10 {approx} 0.55 seconds, and the correlation coefficients between the calculated and the measured values were 0.998 {approx} 0.999. The differences between the maximum and the minimum amplitudes were 0.01 {approx} 0.06 mm, and the reproducibility was within {+-}0.5 mm. In the case of the application and non-application of respiration, the target errors were -0.05 {approx} 1.05 mm and -0.13 {approx} 0.74 mm, respectively, and the entire target errors were 1.30 mm and 0.79 mm, respectively. Based on the accuracy in the RRSS system, various respiration patterns of patients can be reproduced in real-time. Also, this system can be used as an optimal tool for applying patient customized accuracy management in image-guided radiosurgery.

  19. Long term substitution treatment (maintenance treatment of opioid dependent persons

    Directory of Open Access Journals (Sweden)

    Wirl, Charlotte

    2007-03-01

    Full Text Available Health political background: Methadone substitution treatment in Germany is introduced in 1988 in the framework of a scientific pilot study in North Rhein Westphalia. Recent statistics show that by now a broad offer of substitution treatment exists. From 1 June 2002 to 31 December 2003 113,000 substitution treatments have been recorded as being started of which around 56,000 have been recorded as ongoing treatments by 1 December 2003. Scientific background: Substitution treatment (treatment of opioid-dependent persons using substitution substances is one part of addiction treatment. Its goals are harm reduction and the stabilisation of opioid dependent persons. Integration of opioid-dependent persons in a treatment-setting, reduction of consumption of psychoactive substances, reduction of risk behaviour (primarily related to infectious diseases, decrease of mortality and improvements concerning the social, psychic and physic situation are seen as a success of substitution treatment as maintenance therapy. Research questions: The aim of this HTA report is to investigate which indicators can be used to evaluate the effectiveness of substitution treatment. Based on these indicators an evaluation of the medical, social and economical benefit of substitution treatment - also in relation to abstinence oriented treatment - is carried out. Methods: A systematic literature search was performed in 31 international databases which yielded 2451 articles with publication date between 1995 and February 2005. Results: After a twofold selection process 32 publications were included for assessment and 276 publications were used as background literature. Despite serious restrictions due to selection bias and dropout in most studies focusing on substitution treatment, reduction of consumption of illegal opioids, reduction of risk behaviour, criminal behaviour, mortality and incidence of HIV can be seen as an empirically proven success of substitution treatment

  20. [AIT (Adolescent Identity Treatment) - an Integrative Treatment Model for the Treatment of Personality Disorders].

    Science.gov (United States)

    Schlüter-Müller, Susanne

    2017-07-01

    AIT (Adolescent Identity Treatment) - an Integrative Treatment Model for the Treatment of Personality Disorders Personality disorders are patterns of maladaptive personality traits that have an impact on the individual throughout the life span. Borderline Personality Disorder (BPD) is a very severe, but treatable mental disorder. Identity disturbance is seen as the central construct for detecting severe personality pathology - and, most notably, borderline personality disorder - in adults and adolescents. Crises in the development of identity usually resolve into a normal and consolidated identity with flexible and adaptive functioning whereas identity diffusion is viewed as a lack of integration of the concept of the self and significant others. It is seen as the basis for subsequent personality pathology, including that of borderline personality disorder. Although BPD has its onset in adolescence and emerging adulthood the diagnosis is often delayed. In most cases, specific treatment is only offered late in the course of the disorder and to relatively few individuals. Adolescent Identity Treatment (AIT) is a treatment model that focuses on identity pathology as the core characteristic of personality disorders. This model integrates specific techniques for the treatment of adolescent personality pathology on the background of object-relation theories and modified elements of Transference-Focused Psychotherapy. Moreover, psychoeducation, a behavior-oriented homeplan and intensive family work is part of AIT.

  1. Multidisciplinary treatment

    International Nuclear Information System (INIS)

    Hayabuchi, Naofumi; Jingu, Kenichi; Matsuura, Keiichi

    1985-01-01

    Multidisciplinary treatment for malignant lymphoma is reported in terms of indication, current status, and outcome of this approach to Hodgkin's disease (HD) and non-Hodgkin's lymphomas (NLH). HD is considered to be most successfully managed with multidisciplinary treatment. Success of treatment of HD in European countries and the US, which has resulted from accurate staging of HD and developments in radiotherapy and chemotherapy, is reviewed in the literature. Problems in the treatment of HD in Japan are presented. A treatment policy for NHL is discussed according to the original site, i.e. lymph nodes, Waldeyer's ring or other sites of tumor involvement. (Namekawa, K.)

  2. [Treatment of chronic bovine endometritis and factors for treatment success].

    Science.gov (United States)

    Feldmann, M; Tenhagen genannt Emming, S; Hoedemaker, M

    2005-01-01

    In a controlled field trial, 178 dairy cows with chronic endometritis and at least 21 days in lactation were randomly assigned to four different treatment groups: prostaglandin F2alpha intramuscularly (PG, 5 mg dinoprost (5 ml Dinolytic), n = 51), intrauterine antibiotics (AB; 400 mg ampicillin + 800 oxacillin (20 ml Totocillin), n = 49), intrauterine antiseptics (AS; 100 ml 4% Lotagen, n = 50); control (C, no initial treatment, n = 28). Before treatment, uterine swabs for bacteriologic examination and blood samples for determination of serum progesterone concentrations were collected. Two weeks following the first treatment, cows were reexamined. In case no clinical cure was diagnosed, treatment was repeated and control cows were treated for the first time with one of the three treatments mentioned above. The four treatment groups did not differ with respect to the clinical cure or reproductive performance. Therefore, factors that might have an influence on clinical cure and fertility were evaluated. With increasing duration of lactation, the clinical cure after a single treatment increased significantly over all treatment groups from 59.5% (treatment before day 42 postpartum) to 79.6% (treatment following day 42 postpartum) (P conception rate and a lower pregnancy index were obtained when the treatment was performed following day 42 postpartum (P size had a negative effect on clinical cure over all groups (first treatment clinical cure: 68.2% (small uteri) vs 44.4% (large uteri); P 0.05). Isolation of Arcanobacterium (A.) pyogenes negatively influenced first treatment clinical cure over all treatment groups (79.0% vs 31.5%) and within treatment groups (P conception increased compared with the other treatment groups, when A. pyogenes was detected. Isolation of unspecific bacteria and the presence or absence of a corpus luteum only had minor effects over all and within the PG, AS and C group. Within the AB group, presence of luteal tissue was connected with a

  3. [Headache Treatment].

    Science.gov (United States)

    Diener, Hans Christoph; Holle-Lee, Dagny; Nägel, Steffen; Gaul, Charly

    2017-03-01

    A precondition for the successful treatment of headaches is the correct headache diagnosis. Triptans are effective for attack treatment of migraine and cluster headache. However, there are not effective for the treatment of tension-type headache. For the prevention of frequent episodic migraine betablockers, flunarizine, topiramate and amitriptyline are recommended. For the prevention of chronic migraine evidence is only available for onabotulinumtoxinA and topiramate. For prophylactic treatment of tension-type headaches tricyclic antidepressants are used. In cluster headache verapamil (in combination with steroids) is the most frequently used prophylactic agent. This article focusses on the current acute and prophylactic treatment of common headache syndromes. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Tuberculosis Treatment

    African Journals Online (AJOL)

    Tuberculosis Treatment, Lusaka, Zambia. 1. 2. 2. 3. 3 ... TB treatment has contributed to the steady rise of TB incidence in ... respondents (89.4%) had positive attitude towards TB treatment ..... respondents described feelings of depression, anger and apathy .... Journal of Personality and Social Psychology,. 1979, 37:1-11.

  5. Medication-Assisted Treatment For Opioid Addiction in Opioid Treatment Programs. Treatment Improvement Protocol (TIP) Series 43

    Science.gov (United States)

    Tinkler, Emily; Vallejos Bartlett, Catalina; Brooks, Margaret; Gilbert, Johnatnan Max; Henderson, Randi; Shuman, Deborah, J.

    2005-01-01

    TIP 43 provides best-practice guidelines for medication-assisted treatment of opioid addiction in opioid treatment programs (OTPs). The primary intended audience for this volume is substance abuse treatment providers and administrators who work in OTPs. Recommendations in the TIP are based on both an analysis of current research and determinations…

  6. Present status and future aspects of radiation oncology in Korea

    International Nuclear Information System (INIS)

    Huh, Seung Jae

    2006-01-01

    An analysis of the infrastructure for radiotherapy in Korea was performed to establish a baseline plan in 2006 for future development. The data were obtained from 61 radiotherapy centers. The survey covered then number of radiotherapy centers, major equipment and personnel. Centers were classified into technical level groups according to the IAEA criteria. 28,789 new patients were treated with radiation therapy in 2004. There were 104 megavoltage devices in 61 institutions, which included 96 linear accelerators, two Cobalt 60 units, three Tomotherapy units, two Cyberknife units and one proton accelerator in 2006. Thirty-five high dose rate remote after-loading systems and 20 CT-simulators were surveyed. Personnel included 132 radiation oncologists, 50 radiation oncology residents, 64 medical physicists, 130 nurses and 369 radiation therapy technologists. All of the facilities employed treatment-planning computers and simulators, among these thirty-two percent (20 facilities) used a CT-simulator. Sixty-six percent (40 facilities) used a PET/CT scanner, and 35% (22 facilities) had the capacity to implement intensity modulated radiation therapy. Twenty-five facilities (41%) were included in technical level 3 group (having one of intensity modulated radiotherapy, stereotactic radiotherapy or intra-operative radiotherapy system). Radiation oncology in Korea evolved greatly in both quality and quantity recently and demand for radiotherapy in Korea is increasing steadily. The information in this analysis represents important data to develop the future planning of equipment and human resources

  7. Phantom-to-clinic development of hypofractionated stereotactic body radiotherapy for early-stage glottic laryngeal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Chuxiong [Department of Radiation Oncology, Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, TX (United States); Chun, Stephen G. [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Sumer, Baran D. [Department of Otolaryngology, University of Texas Southwestern Medical Center, Dallas, TX (United States); Nedzi, Lucien A.; Abdulrahman, Ramzi E. [Department of Radiation Oncology, Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, TX (United States); Yordy, John S. [Valley Radiation Therapy Center, Anchorage, AK (United States); Lee, Pam; Hrycushko, Brian [Department of Radiation Oncology, Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, TX (United States); Solberg, Timothy D. [Department of Radiation Oncology, Abramson Comprehensive Cancer Center, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA (United States); Ahn, Chul [Department of Clinical Sciences, University of Texas Southwestern Medical Center, Dallas, TX (United States); Timmerman, Robert D. [Department of Radiation Oncology, Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, TX (United States); Schwartz, David L., E-mail: david.schwartz214@gmail.com [Department of Radiation Oncology, Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, TX (United States)

    2017-07-01

    The purpose of this study was to commission and clinically test a robotic stereotactic delivery system (CyberKnife, Sunnyvale, CA) to treat early-stage glottic laryngeal cancer. We enrolled 15 patients with cTis-T2N0M0 carcinoma of the glottic larynx onto an institutional review board (IRB)-approved clinical trial. Stereotactic body radiotherapy (SBRT) plans prescribed 45 Gy/10 fractions to the involved hemilarynx. SBRT dosimetry was compared with (1) standard carotid-sparing laryngeal intensity-modulated radiation therapy (IMRT) and (2) selective hemilaryngeal IMRT. Our results demonstrate that SBRT plans improved sparing of the contralateral arytenoid (mean 20.0 Gy reduction, p <0.001), ipsilateral carotid D{sub max} (mean 20.6 Gy reduction, p <0.001), contralateral carotid D{sub max} (mean 28.1 Gy reduction, p <0.001), and thyroid D{sub mean} (mean 15.0 Gy reduction, p <0.001) relative to carotid-sparing IMRT. SBRT also modestly improved dose sparing to the contralateral arytenoid (mean 4.8 Gy reduction, p = 0.13) and spinal cord D{sub max} (mean 4.9 Gy reduction, p = 0.015) relative to selective hemilaryngeal IMRT plans. This “phantom-to-clinic” feasibility study confirmed that hypofractionated SBRT treatment for early-stage laryngeal cancer can potentially spare dose to adjacent normal tissues relative to current IMRT standards. Clinical efficacy and toxicity correlates continue to be collected through an ongoing prospective trial.

  8. Sequential pathological changes during malignant transformation of a craniopharyngioma: A case report and review of the literature

    Science.gov (United States)

    Negoto, Tetsuya; Sakata, Kiyohiko; Aoki, Takachika; Orito, Kimihiko; Nakashima, Shinji; Hirohata, Masaru; Sugita, Yasuo; Morioka, Motohiro

    2015-01-01

    Background: Malignant transformation of craniopharyngiomas is quite rare, and the etiology of transformation remains unclear. The prognosis of malignantly transformed craniopharyngiomas is very poor. Case Description: A 36-year-old male had five craniotomies, five transsphenoidal surgeries, and two radiation treatments until 31 years of age after diagnosis of craniopharyngioma at 12 years of age. All serial pathological findings indicated adamantinomatous craniopharyngioma including those of a surgery performed for tumor regrowth at 31 years of age. However, when the tumor recurred approximately 5 years later, the pathological findings showed squamous metaplasia. The patient received CyberKnife surgery, but the tumor rapidly regrew within 4 months. The tumor was resected with the cavernous sinus via a dual approach: Transcranial and transsphenoidal surgery with an extracranial-intracranial bypass using the radial artery. Pathologic examination of a surgical specimen showed that it consisted primarily of squamous cells; the lamina propria was collapsed, and the tumor cells had enlarged nuclei and clarification of the nucleolus. The tumor was ultimately diagnosed as malignant transformation of craniopharyngioma. After surgery, he received combination chemotherapy (docetaxel, cisplatin, and fluorouracil). The tumor has been well controlled for more than 12 months. Conclusion: Serial pathological changes of the craniopharyngioma and a review of the 20 cases reported in the literature suggest that radiation of the squamous epithelial cell component of the craniopharyngioma led to malignant transformation via squamous metaplasia. We recommend aggressive surgical removal of craniopharyngiomas and avoidance of radiotherapy if possible. PMID:25883842

  9. Dose-Escalated Robotic SBRT for Stage I-II Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Robert eMeier

    2015-04-01

    Full Text Available Abstract: Stereotactic body radiotherapy (SBRT is the precise external delivery of very high-dose radiotherapy to targets in the body, with treatment completed in one to five fractions. SBRT should be an ideal approach for organ-confined prostate cancer because (I dose escalation should yield improved rates of cancer control; (II the unique radiobiology of prostate cancer favors hypofractionation and (III the conformal nature of SBRT minimizes high-dose radiation delivery to immediately adjacent organs, potentially reducing complications. This approach is also more convenient for patients, and is cheaper than intensity modulated radiotherapy (IMRT. Several external beam platforms are capable of delivering SBRT for early-stage prostate cancer, although most of the mature reported series have employed a robotic non-coplanar platform (i.e., CyberKnife. Several large studies report 5-year biochemical relapse rates which compare favorably to IMRT. Rates of late GU toxicity are similar to those seen with IMRT, and rates of late rectal toxicity may be less than with IMRT and low dose rate (LDR brachytherapy. Patient-reported quality of life (QOL outcomes appear similar to IMRT in the urinary domain. Bowel QOL may be less adversely affected by SBRT than with other radiation modalities. After five years of follow-up, SBRT delivered on a robotic platform is yielding outcomes at least as favorable as IMRT, and may be considered appropriate therapy for stage I-II prostate cancer.

  10. Forecasting pulsatory motion for non-invasive cardiac radiosurgery: an analysis of algorithms from respiratory motion prediction.

    Science.gov (United States)

    Ernst, Floris; Bruder, Ralf; Schlaefer, Alexander; Schweikard, Achim

    2011-01-01

    Recently, radiosurgical treatment of cardiac arrhythmia, especially atrial fibrillation, has been proposed. Using the CyberKnife, focussed radiation will be used to create ablation lines on the beating heart to block unwanted electrical activity. Since this procedure requires high accuracy, the inevitable latency of the system (i.e., the robotic manipulator following the motion of the heart) has to be compensated for. We examine the applicability of prediction algorithms developed for respiratory motion prediction to the prediction of pulsatory motion. We evaluated the MULIN, nLMS, wLMS, SVRpred and EKF algorithms. The test data used has been recorded using external infrared position sensors, 3D ultrasound and the NavX catheter systems. With this data, we have shown that the error from latency can be reduced by at least 10 and as much as 75% (44% average), depending on the type of signal. It has also been shown that, although the SVRpred algorithm was successful in most cases, it was outperformed by the simple nLMS algorithm, the EKF or the wLMS algorithm in a number of cases. We have shown that prediction of cardiac motion is possible and that the algorithms known from respiratory motion prediction are applicable. Since pulsation is more regular than respiration, more research will have to be done to improve frequency-tracking algorithms, like the EKF method, which performed better than expected from their behaviour on respiratory motion traces.

  11. [Preprosthetic orthodontic treatments

    NARCIS (Netherlands)

    Prahl-Andersen, B.; Prahl, C.; Baat, C. de; Creugers, N.H.J.

    2014-01-01

    The objective of a preprosthetic orthodontic treatment is to position the teeth in such a way that a treatment with (fixed) dental prostheses is made possible or simplified or to affect the result of this treatment positively. Conceivable preprosthetic orthodontic treatments are: correcting primary

  12. Reduction of treatment delivery variances with a computer-controlled treatment delivery system

    International Nuclear Information System (INIS)

    Fraass, B.A.; Lash, K.L.; Matrone, G.M.; Lichter, A.S.

    1997-01-01

    Purpose: To analyze treatment delivery variances for 3-D conformal therapy performed at various levels of treatment delivery automation, ranging from manual field setup to virtually complete computer-controlled treatment delivery using a computer-controlled conformal radiotherapy system. Materials and Methods: All external beam treatments performed in our department during six months of 1996 were analyzed to study treatment delivery variances versus treatment complexity. Treatments for 505 patients (40,641 individual treatment ports) on four treatment machines were studied. All treatment variances noted by treatment therapists or quality assurance reviews (39 in all) were analyzed. Machines 'M1' (CLinac (6(100))) and 'M2' (CLinac 1800) were operated in a standard manual setup mode, with no record and verify system (R/V). Machines 'M3' (CLinac 2100CD/MLC) and ''M4'' (MM50 racetrack microtron system with MLC) treated patients under the control of a computer-controlled conformal radiotherapy system (CCRS) which 1) downloads the treatment delivery plan from the planning system, 2) performs some (or all) of the machine set-up and treatment delivery for each field, 3) monitors treatment delivery, 4) records all treatment parameters, and 5) notes exceptions to the electronically-prescribed plan. Complete external computer control is not available on M3, so it uses as many CCRS features as possible, while M4 operates completely under CCRS control and performs semi-automated and automated multi-segment intensity modulated treatments. Analysis of treatment complexity was based on numbers of fields, individual segments (ports), non-axial and non-coplanar plans, multi-segment intensity modulation, and pseudo-isocentric treatments (and other plans with computer-controlled table motions). Treatment delivery time was obtained from the computerized scheduling system (for manual treatments) or from CCRS system logs. Treatment therapists rotate among the machines, so this analysis

  13. Teaching Treatment Planning.

    Science.gov (United States)

    Seligman, Linda

    1993-01-01

    Describes approach to teaching treatment planning that author has used successfully in both seminars and graduate courses. Clarifies nature and importance of systematic treatment planning, then describes context in which treatment planning seems more effectively taught, and concludes with step-by-step plan for teaching treatment planning.…

  14. Antihypertensive treatment

    DEFF Research Database (Denmark)

    Christensen, Cramer; Mogensen, C E

    1987-01-01

    This study was undertaken to clarify whether antihypertensive treatment has any effect on the rate of progression of kidney disease in patients with incipient diabetic nephropathy. Six insulin-dependent diabetic men with incipient nephropathy (urinary albumin excretion above 15 micrograms....../min and total protein excretion below 0.5 g/24 h) were first given metoprolol (200 mg daily) with the subsequent addition of hydroflumethiazide. At the start of antihypertensive treatment, mean patient age was 32 +/- 4.2 years (SD) and mean duration of diabetes was 18 +/- 1.2 years. The patients were followed...... with repeated measurements of urinary albumin excretion for a mean of 5.4 +/- 3.1 years prior to, and for 4.7 +/- 1.3 years (SD) during treatment. Mean arterial blood pressure declined significantly during treatment, e.g., the values at 6 months before initiation of treatment being compared with values during...

  15. Mandometer Treatment Not Superior to Treatment as Usual for Anorexia Nervosa

    NARCIS (Netherlands)

    van Elburg, Annemarie A.; Hillebrand, Jacquelien J. G.; Huyser, Chaim; Snoek, Maartje; Kas, Martien; Hoek, Hans W.; Adan, Roger A. H.

    Objective: A comparison of the efficacy of a novel treatment method for anorexia nervosa (AN), the Mandometer treatment (MT), with treatment as usual (TAU). Method: During treatment data were collected to determine weight recovery and outcome as assessed by the Morgan Russell Outcome Assessment

  16. Analysis of External Treatment Methods and Technical Characteristics of External Treatment

    Science.gov (United States)

    Zhang, Rui; Miao, Mingsan; Bai, Ming

    2018-01-01

    Chinese medicine external therapy is a treatment method of Chinese medicine with Chinese characteristics. The effect of traditional Chinese medicine external treatment, convenient operation, external treatment and technology has great prospects for development. The traditional Chinese medicine external treatment method and technical characteristics were analyzed.

  17. Barriers to Implementing Treatment Integrity Procedures: Survey of Treatment Outcome Researchers

    Science.gov (United States)

    Perepletchikova, Francheska; Hilt, Lori M.; Chereji, Elizabeth; Kazdin, Alan E.

    2009-01-01

    Treatment integrity refers to implementing interventions as intended. Treatment integrity is critically important for experimental validity and for drawing valid inferences regarding the relationship between treatment and outcome. Yet, it is rarely adequately addressed in psychotherapy research. The authors examined barriers to treatment integrity…

  18. Gambling Disorder: Exploring Pre-treatment and In-treatment Dropout Predictors. A UK Study.

    Science.gov (United States)

    Ronzitti, Silvia; Soldini, Emiliano; Smith, Neil; Clerici, Massimo; Bowden-Jones, Henrietta

    2017-12-01

    The aim of this study was to identify predictors of treatment dropout in a sample of gamblers attending a specialist clinic for gambling disorder. We analysed data on 846 treatment-seeking pathological gamblers. Firstly, we investigated differences in socio-demographic and clinical variables between treatment completers and pre-treatment dropouts, as well as between treatment completers and during-treatment dropouts. Subsequently, variables were entered into a multinomial logistic regression model to identify significant predictors of pre-treatment and in-treatment dropout. Overall, 44.8% of clients did not complete the treatment: 27.4% dropped out before starting it, while 17.4% dropped out during the treatment. Younger age and use of drugs were associated with pre-treatment dropout, while family history of gambling disorder, a lower PGSI score, and being a smoker were related with in-treatment dropout. Our findings suggest that pre-treatment dropouts differ from in-treatment dropouts, and, thus, further research will benefit from considering these groups separately. In addition, this newly gained knowledge will also be helpful in increasing treatment retention in specific subgroups of problem gamblers.

  19. Exploring mortality among drug treatment clients: The relationship between treatment type and mortality.

    Science.gov (United States)

    Lloyd, Belinda; Zahnow, Renee; Barratt, Monica J; Best, David; Lubman, Dan I; Ferris, Jason

    2017-11-01

    Studies consistently identify substance treatment populations as more likely to die prematurely compared with age-matched general population, with mortality risk higher out-of-treatment than in-treatment. While opioid-using pharmacotherapy cohorts have been studied extensively, less evidence exists regarding effects of other treatment types, and clients in treatment for other drugs. This paper examines mortality during and following treatment across treatment modalities. A retrospective seven-year cohort was utilised to examine mortality during and in the two years following treatment among clients from Victoria, Australia, recorded on the Alcohol and Drug Information Service database by linking with National Death Index. 18,686 clients over a 12-month period were included. Crude (CMRs) and standardised mortality rates (SMRs) were analysed in terms of treatment modality, and time in or out of treatment. Higher risk of premature death was associated with residential withdrawal as the last type of treatment engagement, while mortality following counselling was significantly lower than all other treatment types in the year post-treatment. Both CMRs and SMRs were significantly higher in-treatment than post-treatment. Better understanding of factors contributing to elevated mortality risk for clients engaged in, and following treatment, is needed to ensure that treatment systems provide optimal outcomes during and after treatment. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Osteoporosis treatment

    DEFF Research Database (Denmark)

    Pazianas, Michael; Abrahamsen, Bo

    2016-01-01

    The findings of the Women's Health Initiative study in 2002 marginalized the use of hormone replacement therapy and established bisphosphonates as the first line of treatment for osteoporosis. Denosumab could be used in selected patients. Although bisphosphonates only maintain the structure of bone...... to their benefits/harm ratio. Treatment of osteoporosis is a long process, and many patients will require treatment with more than one type of drug over their lifetime....

  1. Symptom distress and quality of life after stereotactic radiosurgery in patients with pituitary tumors: a questionnaire survey.

    Directory of Open Access Journals (Sweden)

    Ching-Ju Yang

    Full Text Available BACKGROUND: Stereotactic radiosurgery (SRS is a common treatment for recurrent or residual pituitary adenomas. The persistence of symptoms and treatment related complications may impair the patient's quality of life (QOL. PURPOSE: The purpose of this study was to examine symptom distress, QOL, and the relationship between them among patients with pituitary tumors who had undergone SRS. METHODS: This study used a cross-sectional design and purposive sampling. We enrolled patients diagnosed with pituitary tumors who had undergone SRS. Data were collected at the CyberKnife Center at a medical center in Northern Taiwan in 2012. A questionnaire survey was used for data collection. Our questionnaire consisted of 3 parts the Pituitary Tumor Symptom Distress Questionnaire, the World Health Organization Quality of Life Instrument Short-Form (WHOQOL-BREF, and a demographic questionnaire. RESULTS: Sixty patients were enrolled in the study. The most common symptoms reported by patients after SRS were memory loss, fatigue, blurred vision, headache, sleep problems, and altered libido. The highest and lowest scores for QOL were in the environmental and psychological domains, respectively. Age was positively correlated with general health and the psychological domains. Level of symptom distress was negatively correlated with overall QOL, general health, physical health, and the psychological and social relationships domains. The scores in the psychological and environmental domains were higher in males than in females. Patients with ≤6 symptoms had better overall QOL, general health, physical health, and psychological and social relationships than those with >6 symptoms. CONCLUSION: Symptom distress can affect different aspects of patient QOL. Levels of symptom distress, number of symptoms, age, and gender were variables significantly correlated with patient QOL. These results may be utilized by healthcare personnel to design educational and targeted

  2. Long-Term Outcomes From a Prospective Trial of Stereotactic Body Radiotherapy for Low-Risk Prostate Cancer

    International Nuclear Information System (INIS)

    King, Christopher R.; Brooks, James D.; Gill, Harcharan; Presti, Joseph C.

    2012-01-01

    Purpose: Hypofractionated radiotherapy has an intrinsically different normal tissue and tumor radiobiology. The results of a prospective trial of stereotactic body radiotherapy (SBRT) for prostate cancer with long-term patient-reported toxicity and tumor control rates are presented. Methods and Materials: From 2003 through 2009, 67 patients with clinically localized low-risk prostate cancer were enrolled. Treatment consisted of 36.25 Gy in 5 fractions using SBRT with the CyberKnife as the delivery technology. No patient received hormone therapy. Patient self-reported bladder and rectal toxicities were graded on the Radiation Therapy Oncology Group scale (RTOG). Results: Median follow-up was 2.7 years. There were no grade 4 toxicities. Radiation Therapy Oncology Group Grade 3, 2, and 1 bladder toxicities were seen in 3% (2 patients), 5% (3 patients), and 23% (13 patients) respectively. Dysuria exacerbated by urologic instrumentation accounted for both patients with Grade 3 toxicity. Urinary incontinence, complete obstruction, or persistent hematuria was not observed. Rectal Grade 3, 2, and 1 toxicities were seen in 0, 2% (1 patient), and 12.5% (7 patients), respectively. Persistent rectal bleeding was not observed. Low-grade toxicities were substantially less frequent with QOD vs. QD dose regimen (p = 0.001 for gastrointestinal and p = 0.007 for genitourinary). There were two prostate-specific antigen (PSA), biopsy-proven failures with negative metastatic workup. Median PSA at follow-up was 0.5 ± 0.72 ng/mL. The 4-year Kaplan-Meier PSA relapse-free survival was 94% (95% confidence interval, 85%–102%). Conclusion: Significant late bladder and rectal toxicities from SBRT for prostate cancer are infrequent. PSA relapse-free survival compares favorably with other definitive treatments. The current evidence supports consideration of stereotactic body radiotherapy among the therapeutic options for localized prostate cancer.

  3. Long-Term Outcomes From a Prospective Trial of Stereotactic Body Radiotherapy for Low-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    King, Christopher R., E-mail: crking@mednet.ucla.edu [Departments of Radiation Oncology and Urology, University of California Los Angeles School of Medicine, Los Angeles, CA (United States); Brooks, James D.; Gill, Harcharan; Presti, Joseph C. [Department of Urology, Stanford University School of Medicine, Stanford, CA (United States)

    2012-02-01

    Purpose: Hypofractionated radiotherapy has an intrinsically different normal tissue and tumor radiobiology. The results of a prospective trial of stereotactic body radiotherapy (SBRT) for prostate cancer with long-term patient-reported toxicity and tumor control rates are presented. Methods and Materials: From 2003 through 2009, 67 patients with clinically localized low-risk prostate cancer were enrolled. Treatment consisted of 36.25 Gy in 5 fractions using SBRT with the CyberKnife as the delivery technology. No patient received hormone therapy. Patient self-reported bladder and rectal toxicities were graded on the Radiation Therapy Oncology Group scale (RTOG). Results: Median follow-up was 2.7 years. There were no grade 4 toxicities. Radiation Therapy Oncology Group Grade 3, 2, and 1 bladder toxicities were seen in 3% (2 patients), 5% (3 patients), and 23% (13 patients) respectively. Dysuria exacerbated by urologic instrumentation accounted for both patients with Grade 3 toxicity. Urinary incontinence, complete obstruction, or persistent hematuria was not observed. Rectal Grade 3, 2, and 1 toxicities were seen in 0, 2% (1 patient), and 12.5% (7 patients), respectively. Persistent rectal bleeding was not observed. Low-grade toxicities were substantially less frequent with QOD vs. QD dose regimen (p = 0.001 for gastrointestinal and p = 0.007 for genitourinary). There were two prostate-specific antigen (PSA), biopsy-proven failures with negative metastatic workup. Median PSA at follow-up was 0.5 {+-} 0.72 ng/mL. The 4-year Kaplan-Meier PSA relapse-free survival was 94% (95% confidence interval, 85%-102%). Conclusion: Significant late bladder and rectal toxicities from SBRT for prostate cancer are infrequent. PSA relapse-free survival compares favorably with other definitive treatments. The current evidence supports consideration of stereotactic body radiotherapy among the therapeutic options for localized prostate cancer.

  4. SU-E-T-545: A MLC-Equipped Robotic Radiosurgery-Radiotherapy Combined System in Treating Hepatic Lesions: Delivery Efficiency as Compared to a Standard Linac for Treating Hepatic Lesions

    International Nuclear Information System (INIS)

    Jin, L; Price, R; Wang, L; Meyer, J; Ma, C; Fan, J

    2014-01-01

    Purpose: The CyberKnife (CK) M6 Series introduced a mulitleaf collimator (MLC) beam for extending its capability to the conventional radiotherapy. This work is to investigate delivery efficiency of this system as compared to a standard Varian linac when treating hepatic lesions. Methods: Nine previously treated patients were divided into three groups with three patients in each. Group one: fractionated radiotherapy; Group two: SBRT-like treatments and Group three: fractionated radiotherapy targeting two PTVs. The clinically used plans were generated with the Eclipse treatment planning system (TPS). We re-planned these cases using a Mulitplan (MP) TPS for the CK M6 and normalized to the same PTV dose coverage. CK factors (CF) (defined as modulation scaling factor in this work), number of nodes (NN), number of MLC segments (NS) and beam delivery time (BT) with an estimated image interval of 60 seconds, were used for evaluation of delivery efficiency. Results: Generated plans from the MP and Eclipse TPS demonstrated the similar quality in terms of PTV confomality index, minimum and maximum PTV doses, and doses received by critical structures. Group one: CF ranged from 8.1 to 8.7, NN from 30 to 40, NS from 120 to 155 and BT from 20 to 23 minutes; group two: CF from 4.7 to 8.5, NN from 15 to 19, NS from 82 to 141 and BT from 18 to 24 minutes; and group three: CF from 7.9 to 10, NN from 47 to 49, NS from 110 to 113 and BT from 20 to 22 minutes. Conclusions: Delivery time is longer for the CK M6 than for the Varian linac (7.8 to 13.7 minutes). Further investigation will be necessary to determine if a PTV reduction from the tracking feature will shorten the delivery time without decreasing plan quality

  5. SU-E-T-545: A MLC-Equipped Robotic Radiosurgery-Radiotherapy Combined System in Treating Hepatic Lesions: Delivery Efficiency as Compared to a Standard Linac for Treating Hepatic Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jin, L; Price, R; Wang, L; Meyer, J; Ma, C [Fox Chase Cancer Center, Philadephia, PA (United States); Fan, J [Virtua Fox Chase Cancer Center, Philadelphia, PA (United States)

    2014-06-01

    Purpose: The CyberKnife (CK) M6 Series introduced a mulitleaf collimator (MLC) beam for extending its capability to the conventional radiotherapy. This work is to investigate delivery efficiency of this system as compared to a standard Varian linac when treating hepatic lesions. Methods: Nine previously treated patients were divided into three groups with three patients in each. Group one: fractionated radiotherapy; Group two: SBRT-like treatments and Group three: fractionated radiotherapy targeting two PTVs. The clinically used plans were generated with the Eclipse treatment planning system (TPS). We re-planned these cases using a Mulitplan (MP) TPS for the CK M6 and normalized to the same PTV dose coverage. CK factors (CF) (defined as modulation scaling factor in this work), number of nodes (NN), number of MLC segments (NS) and beam delivery time (BT) with an estimated image interval of 60 seconds, were used for evaluation of delivery efficiency. Results: Generated plans from the MP and Eclipse TPS demonstrated the similar quality in terms of PTV confomality index, minimum and maximum PTV doses, and doses received by critical structures. Group one: CF ranged from 8.1 to 8.7, NN from 30 to 40, NS from 120 to 155 and BT from 20 to 23 minutes; group two: CF from 4.7 to 8.5, NN from 15 to 19, NS from 82 to 141 and BT from 18 to 24 minutes; and group three: CF from 7.9 to 10, NN from 47 to 49, NS from 110 to 113 and BT from 20 to 22 minutes. Conclusions: Delivery time is longer for the CK M6 than for the Varian linac (7.8 to 13.7 minutes). Further investigation will be necessary to determine if a PTV reduction from the tracking feature will shorten the delivery time without decreasing plan quality.

  6. A Retrospective Comparison of Robotic Stereotactic Body Radiotherapy and Three-Dimensional Conformal Radiotherapy for the Reirradiation of Locally Recurrent Nasopharyngeal Carcinoma

    International Nuclear Information System (INIS)

    Ozyigit, Gokhan; Cengiz, Mustafa; Yazici, Gozde; Yildiz, Ferah; Gurkaynak, Murat; Zorlu, Faruk; Yildiz, Demet; Hosal, Sefik; Gullu, Ibrahim; Akyol, Fadil

    2011-01-01

    Purpose: We assessed therapeutic outcomes of reirradiation with robotic stereotactic radiotherapy (SBRT) for locally recurrent nasopharyngeal carcinoma (LRNPC) patients and compared those results with three-dimensional conformal radiotherapy (CRT) with or without brachytherapy (BRT). Methods and Materials: Treatment outcomes were evaluated retrospectively in 51 LRNPC patients receiving either robotic SBRT (24 patients) or CRT with or without BRT (27 patients) in our department. CRT was delivered with a 6-MV linear accelerator, and a median total reirradiation dose of 57 Gy in 2 Gy/day was given. Robotic SBRT was delivered with CyberKnife (Accuray, Sunnyvale, CA). Patients in the SBRT arm received 30 Gy over 5 consecutive days. We calculated actuarial local control and cancer-specific survival rates for the comparison of treatment outcomes in SBRT and CRT arms. The Common Terminology Criteria for Adverse Events v3.0 was used for toxicity evaluation. Results: The median follow-up was 24 months for all patients. Two-year actuarial local control rates were 82% and 80% for SBRT and CRT arms, respectively (p = 0.6). Two-year cancer-specific survival rates were 64% and 47% for the SBRT and CRT arms, respectively (p = 0.4). Serious late toxicities (Grade 3 and above) were observed in 21% of patients in the SBRT arm, whereas 48% of patients had serious toxicity in the CRT arm (p = 0.04). Fatal complications occurred in three patients (12.5%) of the SBRT arm, and four patients (14.8%) of the CRT arm (p = 0.8). T stage at recurrence was the only independent predictor for local control and survival. Conclusion: Our robotic SBRT protocol seems to be feasible and less toxic in terms of late effects compared with CRT arm for the reirradiation of LRNPC patients.

  7. Quality of Life and Toxicity after SBRT for Organ-Confined Prostate Cancer, a Seven Year Study

    Directory of Open Access Journals (Sweden)

    Alan Jay Katz

    2014-10-01

    Full Text Available Objectives: Stereotactic body radiation therapy (SBRT yields excellent disease control for lowandintermediate-risk prostate cancer by delivering high doses of radiation in a small number offractions. Our report presents a 7-year update on treatment toxicity and quality of life (QOLfrom 515 patients treated with prostate SBRT.Methods: From 2006 to 2009, 515 patients with clinically localized, low-, intermediate- andhigh-risk prostate cancer were treated with SBRT using Cyberknife technology. Treatmentconsisted of 35 to 36.25 Gy in 5 fractions. Seventy-two patients received hormone therapy.Toxicity was assessed at each follow up visit using the Expanded Prostate Cancer IndexComposite (EPIC questionnaire and the Radiation Therapy Oncology Group (RTOG urinaryand rectal toxicity scale.Results: Median follow up was 72 months. The actuarial 7-year freedom from biochemicalfailure was 95.8%, 89.3% and 68.5% for low-, intermediate- and high-risk groups, respectively(p < 0.001. No patients experienced acute Grade III or IV acute complications. Fewer than 5%of patients had any acute Grade II urinary or rectal toxicity. Late toxicity was low, with Grade IIrectal and urinary toxicity of 4% and 9.1%, respectively, and Grade III urinary toxicity of 1.7%.Mean EPIC urinary and bowel QOL declined at 1 month post-treatment, returned to baseline by2 years and remained stable thereafter. EPIC sexual QOL declined by 23% at 6-12 months andremained stable afterwards. Of patients potent at baseline evaluation, 67% remained potent atlast follow-up.Conclusions: This study suggests that SBRT, when administered to doses of 35 to 36.25 Gy, isefficacious and safe. With long-term follow up in our large patient cohort, we continue to findlow rates of late toxicity and excellent rates of biochemical control.

  8. Optimizing clozapine treatment

    DEFF Research Database (Denmark)

    Nielsen, Jimmi; Damkier, P; Lublin, Henrik

    2011-01-01

    Clozapine treatment remains the gold standard for treatment-resistant schizophrenia, but treatment with clozapine is associated with several side-effects that complicate the use of the drug. This clinical overview aims to provide psychiatrists with knowledge about how to optimize clozapine...... treatment. Relevant strategies for reducing side-effects and increasing the likelihood of response are discussed....

  9. MO-FG-BRA-07: Intrafractional Motion Effect Can Be Minimized in Tomotherapy Stereotactic Body Radiotherapy (SBRT)

    Energy Technology Data Exchange (ETDEWEB)

    Price, A; Chang, S; Matney, J; Wang, A; Lian, J [University of North Carolina, Chapel Hill, NC (United States); Chao, E [Accuray Incorporated, Madison, WI (United States)

    2016-06-15

    Purpose: Tomotherapy has unique challenges in handling intrafractional motion compared to conventional LINAC. In this study, we analyzed the impact of intrafractional motion on cumulative dosimetry using actual patient motion data and investigated real time jaw/MLC compensation approaches to minimize the motion-induced dose discrepancy in Tomotherapy SBRT treatment. Methods: Intrafractional motion data recorded in two CyberKnife lung treatment cases through fiducial tracking and two LINAC prostate cases through Calypso tracking were used in this study. For each treatment site, one representative case has an average motion (6mm) and one has a large motion (10mm for lung and 15mm for prostate). The cases were re-planned on Tomotherapy for SBRT. Each case was planned with 3 different jaw settings: 1cm static, 2.5cm dynamic, and 5cm dynamic. 4D dose accumulation software was developed to compute dose with the recorded motions and theoretically compensate motions by modifying original jaw and MLC to track the trajectory of the tumor. Results: PTV coverage in Tomotherapy SBRT for patients with intrafractional motion depends on motion type, amplitude and plan settings. For the prostate patient with large motion, PTV coverage changed from 97.2% (motion-free) to 47.1% (target motion-included), 96.6% to 58.5% and 96.3% to 97.8% for the 1cm static jaw, 2.5cm dynamic jaw and 5cm dynamic jaw setting, respectively. For the lung patient with large motion, PTV coverage discrepancies showed a similar trend of change. When the jaw and MLC compensation program was engaged, the motion compromised PTV coverage was recovered back to >95% for all cases and plans. All organs at risk (OAR) were spared with < 5% increase from original motion-free plans. Conclusion: Tomotherapy SBRT is less motion-impacted when 5cm dynamic jaw is used. Once the motion pattern is known, the jaw and MLC compensation program can largely minimize the compromised target coverage and OAR sparing.

  10. MO-FG-BRA-07: Intrafractional Motion Effect Can Be Minimized in Tomotherapy Stereotactic Body Radiotherapy (SBRT)

    International Nuclear Information System (INIS)

    Price, A; Chang, S; Matney, J; Wang, A; Lian, J; Chao, E

    2016-01-01

    Purpose: Tomotherapy has unique challenges in handling intrafractional motion compared to conventional LINAC. In this study, we analyzed the impact of intrafractional motion on cumulative dosimetry using actual patient motion data and investigated real time jaw/MLC compensation approaches to minimize the motion-induced dose discrepancy in Tomotherapy SBRT treatment. Methods: Intrafractional motion data recorded in two CyberKnife lung treatment cases through fiducial tracking and two LINAC prostate cases through Calypso tracking were used in this study. For each treatment site, one representative case has an average motion (6mm) and one has a large motion (10mm for lung and 15mm for prostate). The cases were re-planned on Tomotherapy for SBRT. Each case was planned with 3 different jaw settings: 1cm static, 2.5cm dynamic, and 5cm dynamic. 4D dose accumulation software was developed to compute dose with the recorded motions and theoretically compensate motions by modifying original jaw and MLC to track the trajectory of the tumor. Results: PTV coverage in Tomotherapy SBRT for patients with intrafractional motion depends on motion type, amplitude and plan settings. For the prostate patient with large motion, PTV coverage changed from 97.2% (motion-free) to 47.1% (target motion-included), 96.6% to 58.5% and 96.3% to 97.8% for the 1cm static jaw, 2.5cm dynamic jaw and 5cm dynamic jaw setting, respectively. For the lung patient with large motion, PTV coverage discrepancies showed a similar trend of change. When the jaw and MLC compensation program was engaged, the motion compromised PTV coverage was recovered back to >95% for all cases and plans. All organs at risk (OAR) were spared with < 5% increase from original motion-free plans. Conclusion: Tomotherapy SBRT is less motion-impacted when 5cm dynamic jaw is used. Once the motion pattern is known, the jaw and MLC compensation program can largely minimize the compromised target coverage and OAR sparing.

  11. Treatment agreement, adherence, and outcome in cognitive behavioral treatments for insomnia.

    Science.gov (United States)

    Dong, Lu; Soehner, Adriane M; Bélanger, Lynda; Morin, Charles M; Harvey, Allison G

    2018-03-01

    Patient adherence has been identified as an important barrier to the implementation of evidence-based psychological treatments. In cognitive behavioral treatments (CBT) for insomnia, the current study examined (a) the validity of therapist ratings of patient agreement and adherence against an established behavioral measure of adherence, and (b) the relationship between treatment agreement, adherence, and outcome. Participants were 188 adults meeting DSM-IV-TR criteria for chronic insomnia who were randomized to receive behavior therapy, cognitive therapy, or CBT for insomnia. Treatment agreement/adherence was measured by (a) weekly therapist ratings of patient agreement and homework completion, and (b) adherence to behavioral strategies (ABS) derived from patient-reported sleep diary. Outcome measures were Insomnia Severity Index and insomnia remission (Insomnia Severity Index adherence, and ABS measures during treatment significantly predicted insomnia remission at posttreatment, and all but therapist rating of homework completion predicted remission at 6-month follow-up. Greater patient agreement and adherence (therapist ratings and ABS) during treatment predicted better treatment outcome. Therapist-rated treatment agreement and adherence correspond well with patient-reported sleep diary-derived adherence measure. These simple, deployable therapist-rated patient agreement and adherence can potentially be useful for treatments for other disorders. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  12. Treatment Wetlands

    OpenAIRE

    Dotro, Gabriela; Langergraber, Günter; Molle, Pascal; Nivala, Jaime; Puigagut, Jaume; Stein, Otto; Von Sperling, Marcos

    2017-01-01

    Overview of Treatment Wetlands; Fundamentals of Treatment Wetlands; Horizontal Flow Wetlands; Vertical Flow Wetlands; French Vertical Flow Wetlands; Intensified and Modified Wetlands; Free Water Surface Wetlands; Other Applications; Additional Aspects.

  13. Patients' perceptions, treatment need, and complexity of orthodontic re-treatment

    NARCIS (Netherlands)

    Ren, Yijin; Boxum, Christo; Sandham, John

    The aim of the present study was to investigate the subjective perception and objective treatment need and complexity of patients seeking orthodontic re-treatment. One hundred subjects (66 females, 34 males, age 26.7+/-8.2 years) seeking re-treatment were asked to complete a questionnaire which was

  14. Tuberculosis (TB): Treatment

    Science.gov (United States)

    ... Education & Training Home Conditions Tuberculosis (TB) Tuberculosis: Treatment Tuberculosis: Treatment Make an Appointment Refer a Patient Ask ... or bones is treated longer. NEXT: Preventive Treatment Tuberculosis: Diagnosis Tuberculosis: History Clinical Trials For more than ...

  15. Hyperthermia treatment planning

    International Nuclear Information System (INIS)

    Lagendijk, J.J.W.

    2000-01-01

    The development of hyperthermia, the treatment of tumours with elevated temperatures in the range of 40-44 deg. C with treatment times over 30 min, greatly benefits from the development of hyperthermia treatment planning. This review briefly describes the state of the art in hyperthermia technology, followed by an overview of the developments in hyperthermia treatment planning. It particularly highlights the significant problems encountered with heating realistic tissue volumes and shows how treatment planning can help in designing better heating technology. Hyperthermia treatment planning will ultimately provide information about the actual temperature distributions obtained and thus the tumour control probabilities to be expected. This will improve our understanding of the present clinical results of thermoradiotherapy and thermochemotherapy, and will greatly help both in optimizing clinical heating technology and in designing optimal clinical trials. (author)

  16. Hepatitis C: Treatment

    Science.gov (United States)

    ... Public Home » Hepatitis C » Hepatitis C Treatment Viral Hepatitis Menu Menu Viral Hepatitis Viral Hepatitis Home For ... Enter ZIP code here Enter ZIP code here Hepatitis C Treatment for Veterans and the Public Treatment ...

  17. Cryptosporidium: Treatment

    Science.gov (United States)

    ... lt;/label> Parasites Home Treatment Recommend on Facebook Tweet Share Compartir Most people who have healthy immune systems will recover without treatment. Diarrhea can be managed by drinking plenty of fluids to prevent dehydration. ...

  18. Treatment non-response: Associations with smoking expectancies among treatment-seeking smokers.

    Science.gov (United States)

    Garey, Lorra; Taha, Samar A; Kauffman, Brooke Y; Manning, Kara F; Neighbors, Clayton; Schmidt, Norman B; Zvolensky, Michael J

    2017-10-01

    Despite the high rate of smoking cessation treatment non-response, relatively little empirical work has examined predictors of treatment non-response. The present study sought to explore the effect of smoking outcome expectancies on treatment response in a sample of treatment-seeking adult daily smokers (N=182; 53.3% female; M age =40.67; SD=13.63). Results indicated that expectancies for smoking to reduce negative affect were related to an increased likelihood of treatment non-response (OR=0.73, CI: 0.54, 0.98). These findings remained significant after controlling for sex, presence of Axis I disorder, tobacco-related health problems, tobacco dependence, anxiety sensitivity, and condition assignment as well as other smoking expectancy dimensions. Post hoc analyses revealed that this relation was stronger for smokers in the integrated care condition vs. the standard care condition (Interaction: OR=1.69, CI: 1.05, 2.73). Additionally, expectancies for smoking to enhance positive affect and provide sensory satisfaction were associated with an increased likelihood of treatment response in the standard care condition. The current findings suggest expectancies that smoking will alleviate negative affect may be a risk factor of smoking cessation treatment non-response. Additionally, findings provide evidence that the relation between smoking expectancies and treatment non-response may differ by smoking cessation treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Ankle Sprain Treatment

    Science.gov (United States)

    ... Issues Listen Español Text Size Email Print Share Ankle Sprain Treatment Page Content Article Body Acute ankle and ... Pediatrics summarizing the treatment phases of rehabilitation for ankle sprain. Phase Summary Description I Phase I treatment involves ...

  20. Dosimetric evaluation of 4 different treatment modalities for curative-intent stereotactic body radiation therapy for isolated thoracic spinal metastases

    International Nuclear Information System (INIS)

    Yang, Jun; Ma, Lin; Wang, Xiao-Shen; Xu, Wei Xu; Cong, Xiao-Hu; Xu, Shou-Ping; Ju, Zhong-Jian; Du, Lei; Cai, Bo-Ning; Yang, Jack

    2016-01-01

    To investigate the dosimetric characteristics of 4 SBRT-capable dose delivery systems, CyberKnife (CK), Helical TomoTherapy (HT), Volumetric Modulated Arc Therapy (VMAT) by Varian RapidArc (RA), and segmental step-and-shoot intensity-modulated radiation therapy (IMRT) by Elekta, on isolated thoracic spinal lesions. CK, HT, RA, and IMRT planning were performed simultaneously for 10 randomly selected patients with 6 body types and 6 body + pedicle types with isolated thoracic lesions. The prescription was set with curative intent and dose of either 33 Gy in 3 fractions (3F) or 40 Gy in 5F to cover at least 90% of the planning target volume (PTV), correspondingly. Different dosimetric indices, beam-on time, and monitor units (MUs) were evaluated to compare the advantages/disadvantages of each delivery modality. In ensuring the dose-volume constraints for cord and esophagus of the premise, CK, HT, and RA all achieved a sharp conformity index (CI) and a small penumbra volume compared to IMRT. RA achieved a CI comparable to those from CK, HT, and IMRT. CK had a heterogeneous dose distribution in the target as its radiosurgical nature with less dose uniformity inside the target. CK had the longest beam-on time and the largest MUs, followed by HT and RA. IMRT presented the shortest beam-on time and the least MUs delivery. For the body-type lesions, CK, HT, and RA satisfied the target coverage criterion in 6 cases, but the criterion was satisfied in only 3 (50%) cases with the IMRT technique. For the body + pedicle-type lesions, HT satisfied the criterion of the target coverage of ≥90% in 4 of the 6 cases, and reached a target coverage of 89.0% in another case. However, the criterion of the target coverage of ≥90% was reached in 2 cases by CK and RA, and only in 1 case by IMRT. For curative-intent SBRT of isolated thoracic spinal lesions, RA is the first choice for the body-type lesions owing to its delivery efficiency (time); the second choice is CK or HT; HT is the

  1. Dosimetric evaluation of 4 different treatment modalities for curative-intent stereotactic body radiation therapy for isolated thoracic spinal metastases

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jun [Department of Radiation Oncology, Chinese PLA General Hospital, 28 Fuxing Road, Beijing, 100853 (China); Department of Oncology, First Affiliated Hospital of Xinxiang Medical University, 88 Jiankang Road, Weihui, Henan, 453100 (China); Ma, Lin [Department of Radiation Oncology, Chinese PLA General Hospital, 28 Fuxing Road, Beijing, 100853 (China); Department of Radiation Oncology, Hainan Branch of Chinese PLA General Hospital, Haitang Bay, Sanya, 572000 (China); Wang, Xiao-Shen; Xu, Wei Xu; Cong, Xiao-Hu; Xu, Shou-Ping; Ju, Zhong-Jian [Department of Radiation Oncology, Chinese PLA General Hospital, 28 Fuxing Road, Beijing, 100853 (China); Du, Lei [Department of Radiation Oncology, Hainan Branch of Chinese PLA General Hospital, Haitang Bay, Sanya, 572000 (China); Cai, Bo-Ning [Department of Radiation Oncology, Chinese PLA General Hospital, 28 Fuxing Road, Beijing, 100853 (China); Yang, Jack [Department of Radiation Oncology, Monmouth Medical Center, 300 2nd Avenue, Long Branch, NJ 07740 (United States)

    2016-07-01

    To investigate the dosimetric characteristics of 4 SBRT-capable dose delivery systems, CyberKnife (CK), Helical TomoTherapy (HT), Volumetric Modulated Arc Therapy (VMAT) by Varian RapidArc (RA), and segmental step-and-shoot intensity-modulated radiation therapy (IMRT) by Elekta, on isolated thoracic spinal lesions. CK, HT, RA, and IMRT planning were performed simultaneously for 10 randomly selected patients with 6 body types and 6 body + pedicle types with isolated thoracic lesions. The prescription was set with curative intent and dose of either 33 Gy in 3 fractions (3F) or 40 Gy in 5F to cover at least 90% of the planning target volume (PTV), correspondingly. Different dosimetric indices, beam-on time, and monitor units (MUs) were evaluated to compare the advantages/disadvantages of each delivery modality. In ensuring the dose-volume constraints for cord and esophagus of the premise, CK, HT, and RA all achieved a sharp conformity index (CI) and a small penumbra volume compared to IMRT. RA achieved a CI comparable to those from CK, HT, and IMRT. CK had a heterogeneous dose distribution in the target as its radiosurgical nature with less dose uniformity inside the target. CK had the longest beam-on time and the largest MUs, followed by HT and RA. IMRT presented the shortest beam-on time and the least MUs delivery. For the body-type lesions, CK, HT, and RA satisfied the target coverage criterion in 6 cases, but the criterion was satisfied in only 3 (50%) cases with the IMRT technique. For the body + pedicle-type lesions, HT satisfied the criterion of the target coverage of ≥90% in 4 of the 6 cases, and reached a target coverage of 89.0% in another case. However, the criterion of the target coverage of ≥90% was reached in 2 cases by CK and RA, and only in 1 case by IMRT. For curative-intent SBRT of isolated thoracic spinal lesions, RA is the first choice for the body-type lesions owing to its delivery efficiency (time); the second choice is CK or HT; HT is the

  2. After Cancer Treatment

    Science.gov (United States)

    ... Better Home Your Health Resources Healthcare Management After Cancer Treatment After Cancer Treatment Share Print From the day you were diagnosed ... of the questions you may have after your cancer treatment ends. Path to well being Will I need ...

  3. Distributed Treatment Systems.

    Science.gov (United States)

    Zgonc, David; Plante, Luke

    2017-10-01

    This section presents a review of the literature published in 2016 on topics relating to distributed treatment systems. This review is divided into the following sections with multiple subsections under each: constituent removal; treatment technologies; and planning and treatment system management.

  4. Inter-treatment compensation of treatment setup variation to enhance the radiotherapeutic ratio

    International Nuclear Information System (INIS)

    Di, Yan; John, Wong; Michalski, Jeff; Pan, Cheng; Frazier, Arthur; Bosch, Walter; Martinez, Alvaro

    1995-01-01

    Purpose: In radiotherapy, treatment setup error has been one of the major causes of dose variation in the treated volume. With the data acquired from on-line electronic portal imaging, it is now possible not only to adjust the patient setup, but also to modify the treatment plan during the course of clinical treatment based on the setup error measured for each individual patient. In this work, daily clinical portal images were retrospectively analyzed to study (1) the number of initial daily portal images required to give adequate prediction of the systematic and random deviations of treatment setup, and (2) the potential therapeutic gain when the inter-treatment planning modification was established using the setup error of each individual patient. Methods and Materials: Only those patients whose treatment positions had not been adjusted during the course of treatment were selected for the retrospective study. Daily portal images of 27 lung, 25 pelvis, and 12 head and neck (h and n) cancer patients were obtained from two independent clinics with similar setup procedures. The anterior-to-posterior field was analyzed for the pelvis and lung treatments, and the right lateral field for the h and n treatments. Between 13 to 30 daily portal images were acquired for each patient and were analyzed using a 2D alignment tool. Systematic and random deviations of the treatment setup were calculated for each individual patient. The statistical confidence on the convergence of both systematic and random deviations with time were tested to determine the number of initial daily portal images needed to predict these deviations. In addition, a mean deviation for each site was also calculated using the setup errors from all patients. Two treatment planning schemes were simulated to evaluate margin design and prescription dose adjustment. Therapeutic scores were quantified in terms of tumor control probability (TCP) and normal tissue complication probability (NTCP). In the first

  5. Cancer treatments

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000901.htm Cancer treatments To use the sharing features on this page, ... or IV. Immunotherapy Immunotherapy is a type of cancer treatment that relies on the body's ability to fight ...

  6. Evidence-based treatment strategies for treatment-resistant bipolar depression: a systematic review

    NARCIS (Netherlands)

    Sienaert, P.; Lambrichts, L.; Dols, A.; De Fruyt, J.

    2013-01-01

    Objectives: Treatment resistance in bipolar depression is a common clinical problem that constitutes a major challenge for the treating clinician as there is a paucity of treatment options. The objective of this paper was to review the evidence for treatment options in treatment-resistant bipolar

  7. Risk factors for treatment default among re-treatment tuberculosis patients in India, 2006.

    Science.gov (United States)

    Jha, Ugra Mohan; Satyanarayana, Srinath; Dewan, Puneet K; Chadha, Sarabjit; Wares, Fraser; Sahu, Suvanand; Gupta, Devesh; Chauhan, L S

    2010-01-25

    Under India's Revised National Tuberculosis Control Programme (RNTCP), >15% of previously-treated patients in the reported 2006 patient cohort defaulted from anti-tuberculosis treatment. To assess the timing, characteristics, and risk factors for default amongst re-treatment TB patients. For this case-control study, in 90 randomly-selected programme units treatment records were abstracted from all 2006 defaulters from the RNTCP re-treatment regimen (cases), with one consecutively-selected non-defaulter per case. Patients who interrupted anti-tuberculosis treatment for >2 months were classified as defaulters. 1,141 defaulters and 1,189 non-defaulters were included. The median duration of treatment prior to default was 81 days (25%-75% interquartile range 44-117 days) and documented retrieval efforts after treatment interruption were inadequate. Defaulters were more likely to have been male (adjusted odds ratio [aOR] 1.4, 95% confidence interval [CI] 1.2-1.7), have previously defaulted anti-tuberculosis treatment (aOR 1.3 95%CI 1.1-1.6], have previous treatment from non-RNTCP providers (AOR 1.3, 95%CI 1.0-1.6], or have public health facility-based treatment observation (aOR 1.3, 95%CI 1.1-1.6). Amongst the large number of re-treatment patients in India, default occurs early and often. Improved pre-treatment counseling and community-based treatment provision may reduce default rates. Efforts to retrieve treatment interrupters prior to default require strengthening.

  8. Treatment beliefs underlying intended treatment choices in knee and hip osteoarthritis

    NARCIS (Netherlands)

    Selten, E.M.H.; Geenen, R.; Schers, H.J.; van den Hoogen, F.H.J.; van der Meulen-Dilling, R.G.; Van der Laan, W.H.; Nijhof, M.W.; van den Ende, C.H.M.; Vriezekolk, J.E.

    Purpose Patients’ beliefs about treatment modalities for knee and hip osteoarthritis (OA) will underlie their treatment choices. Based on the Theory of Planned Behavior, it is hypothesized that patients’ beliefs, subjective norm, and perceived behavioral control guide their treatment choices. Also,

  9. Treatment of Epileptic Encephalopathies.

    Science.gov (United States)

    Balestrini, Simona; Sisodiya, Sanjay M

    2017-01-01

    Epileptic encephalopathies represent the most severe epilepsies, with onset in infancy and childhood and seizures continuing in adulthood in most cases. New genetic causes are being identified at a rapid rate. Treatment is challenging and the overall outcome remains poor. Available targeted treatments, based on the precision medicine approach, are currently few. To provide an overview of the treatment of epileptic encephalopathies with known genetic determinants, including established treatment, anecdotal reports of specific treatment, and potential tailored precision medicine strategies. Genes known to be associated to epileptic encephalopathy were selected. Genes where the association was uncertain or with no reports of details on treatment, were not included. Although some of the genes included are associated with multiple epilepsy phenotypes or other organ involvement, we have mainly focused on the epileptic encephalopathies and their antiepileptic treatments. Most epileptic encephalopathies show genotypic and phenotypic heterogeneity. The treatment of seizures is difficult in most cases. The available evidence may provide some guidance for treatment: for example, ACTH seems to be effective in controlling infantile spams in a number of genetic epileptic encephalopathies. There are potentially effective tailored precision medicine strategies available for some of the encephalopathies, and therapies with currently unexplained effectiveness in others. Understanding the effect of the mutation is crucial for targeted treatment. There is a broad range of disease mechanisms underlying epileptic encephalopathies, and this makes the application of targeted treatments challenging. However, there is evidence that tailored treatment could significantly improve epilepsy treatment and prognosis. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  10. Somatic Treatments in Treatment of Depression During Pregnancy

    Directory of Open Access Journals (Sweden)

    Eylem Ozten

    2015-09-01

    Full Text Available Although some psychotropic drugs are known to be teratogenic no psychotropic drug is of proven safety for treatment of depression during pregnancy. Untreated mood disorders during pregnancy pose significant risks for mother and the newborn. This review focuses on the use of somatic tretments of depression during pregnancy.Electroconvulsive therapy, bright light therapy, transcranial magnetic stimulation and vagal nerve stimulation are relatively safe and effective treatments during pregnancy if steps are taken to decrease potential risks. A clear information related to the somatic treatment should be given to the patient and informed consent should be obtained. [Psikiyatride Guncel Yaklasimlar - Current Approaches in Psychiatry 2015; 7(3.000: 244-254

  11. Characteristics and performance of the first commercial multileaf collimator for a robotic radiosurgery system

    Energy Technology Data Exchange (ETDEWEB)

    Fürweger, Christoph, E-mail: christoph.fuerweger@cyber-knife.net [Department of Radiation Oncology, Erasmus MC Cancer Institute, Rotterdam 3075 EA, The Netherlands and European CyberKnife Center Munich, Munich 81377 (Germany); Prins, Paulette; Coskan, Harun; Heijmen, Ben J. M. [Department of Radiation Oncology, Erasmus MC Cancer Institute, Rotterdam 3075 EA (Netherlands)

    2016-05-15

    Purpose: The “InCise™ multileaf-collimator (MLC)” is the first commercial MLC to be mounted on a robotic SRS/SBRT platform (CyberKnife). The authors assessed characteristics and performance of this novel device in a preclinical five months test period. Methods: Commissioning beam data were acquired with unshielded diodes. EBT3 radiochromic films were employed for measurement of transmission, leaf/bank position accuracy (garden fence) before and after exercising the MLC, for end-to-end testing and further characterization of the beam. The robot workspace with MLC was assessed analytically by transformation to an Euler geometry (“plane,” “gantry,” and “collimator” angles) and by measuring pointing accuracy at each node. Stability over time was evaluated in picket fence and adapted Winston–Lutz tests (AQA). Results: Beam penumbrae (80%–20%, with 100% = 2 × dose at inflection point for field sizes ≥ 50 × 50 mm{sup 2}) were 2.2–3.7 mm for square fields in reference condition (source-axis-distance 800 mm, depth 15 mm) and depended on field size and off-axis position. Transmission and leakage did not exceed 0.5%. Accessible clinical workspace with MLC covered non-coplanar gantry angles of [−113°; +112°] and collimator angles of [−100°; +107°], with an average robot pointing accuracy of 0.12 ± 0.09 mm. For vertical beams, garden fence tests exhibited an average leaf positioning error of ≤0.2 mm, which increased by 0.25 and 0.30 mm (banks X1 and X2) with leaves traveling parallel to gravity. After execution of a leaf motion stress routine, garden fence tests showed slightly increased jaggedness and allowed to identify one malfunctioning leaf motor. Total system accuracy with MLC was 0.38 ± 0.05 mm in nine end-to-end tests. Picket fence and AQA tests displayed stable results over the test period. Conclusions: The InCise™ MLC for CyberKnife showed high accuracy and adequate characteristics for SRS/SBRT applications. MLC performance

  12. Characteristics and performance of the first commercial multileaf collimator for a robotic radiosurgery system

    International Nuclear Information System (INIS)

    Fürweger, Christoph; Prins, Paulette; Coskan, Harun; Heijmen, Ben J. M.

    2016-01-01

    Purpose: The “InCise™ multileaf-collimator (MLC)” is the first commercial MLC to be mounted on a robotic SRS/SBRT platform (CyberKnife). The authors assessed characteristics and performance of this novel device in a preclinical five months test period. Methods: Commissioning beam data were acquired with unshielded diodes. EBT3 radiochromic films were employed for measurement of transmission, leaf/bank position accuracy (garden fence) before and after exercising the MLC, for end-to-end testing and further characterization of the beam. The robot workspace with MLC was assessed analytically by transformation to an Euler geometry (“plane,” “gantry,” and “collimator” angles) and by measuring pointing accuracy at each node. Stability over time was evaluated in picket fence and adapted Winston–Lutz tests (AQA). Results: Beam penumbrae (80%–20%, with 100% = 2 × dose at inflection point for field sizes ≥ 50 × 50 mm"2) were 2.2–3.7 mm for square fields in reference condition (source-axis-distance 800 mm, depth 15 mm) and depended on field size and off-axis position. Transmission and leakage did not exceed 0.5%. Accessible clinical workspace with MLC covered non-coplanar gantry angles of [−113°; +112°] and collimator angles of [−100°; +107°], with an average robot pointing accuracy of 0.12 ± 0.09 mm. For vertical beams, garden fence tests exhibited an average leaf positioning error of ≤0.2 mm, which increased by 0.25 and 0.30 mm (banks X1 and X2) with leaves traveling parallel to gravity. After execution of a leaf motion stress routine, garden fence tests showed slightly increased jaggedness and allowed to identify one malfunctioning leaf motor. Total system accuracy with MLC was 0.38 ± 0.05 mm in nine end-to-end tests. Picket fence and AQA tests displayed stable results over the test period. Conclusions: The InCise™ MLC for CyberKnife showed high accuracy and adequate characteristics for SRS/SBRT applications. MLC performance after

  13. [Home treatment--a treatment model of integrated care in Hamburg].

    Science.gov (United States)

    Schöttle, Daniel; Ruppelt, Friederike; Karow, Anne; Lambert, Martin

    2015-03-01

    Treatment models like "Crisis Resolution and Hometreatment (CRHT)" or "Assertive Community Treatment" (ACT), were found to be effective, enhancing the qualitative level of treatment for patients with severe mental disorders. In Germany, these are implemented only sporadically until today, often as part of a cross-sectoral Integrated Care (IC) treatment system. We will present the implementation of an "Assertive Community Treatment" embedded into an IC-treatment model in Hamburg and discuss the 3-year-outcomes. The IC-treatment model has been designed for severe mentally ill patients with psychotic disorders. Since May 2007 the model is financed by different health insurances as a managed-care "capitation-model" and its effectiveness gets continuously evaluated. The model proved to be effective in earlier studies were compared with standard care low rates of service disengagement were found as well as significantly improved psychopathology, psychosocial functioning, quality of life, satisfaction with care and adherence, while being cost effective. The rates of involuntary admissions declined to 10% in comparison to the years before. In 2011 the model was specified to the indication "first-episode adolescents and young adults in the age of 12-29" in a government-funded study "Integrated Care in Early Psychosis, ICEP Study". In this study an interdisciplinary team of child, adolescent and adult psychiatrists was implemented and since 2012 it is financed by the involved health insurances throughout an expansion of the §140 SGB V agreement. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Pathways to treatment retention for individuals legally coerced to substance use treatment: the interaction of hope and treatment motivation.

    Science.gov (United States)

    Hampton, Ashley S; Conner, Bradley T; Albert, Dustin; Anglin, M Douglas; Urada, Darren; Longshore, Douglas

    2011-11-01

    Although several states have adopted policies diverting individuals convicted of non-violent drug offenses to substance use treatment, in lieu of incarceration or as a condition of probation, previous research has produced inconsistent findings on the effectiveness of such programs when comparing outcomes for legally coerced individuals to more voluntary entrants. Less studied in these populations is within group variation in treatment expectations and motivation influences, which have been shown to affect retention as well. As motivation has traditionally been viewed as contributing to treatment retention and higher levels of hope (the perception that goals can be met) are viewed as an asset in treatment, the role of these factors in predicting better retention between legally coerced and more voluntary clients were examined in a sample of 289 treatment admissions in California. Results found that motivation mediates the relationship between hope and retention for participants in general. Although the differences in mediation between the legally coerced and the non-legally coerced were not significant, when examining the groups separately, there was a significant mediation of the relationship between hope and retention by motivation only for those individuals who were not legally coerced into treatment (plead to different pathways to treatment retention, for individuals who were not legally coerced, higher levels of hope may play an important role in determining treatment retention. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  15. Treatment consumption and treatment re-enrollment in GHB-dependent patients in The Netherlands.

    Science.gov (United States)

    van Noorden, Martijn S; Mol, Ton; Wisselink, Jeroen; Kuijpers, Wil; Dijkstra, Boukje A G

    2017-07-01

    The objective of this study was to assess treatment consumption and re-enrollment in treatment in patients with gamma-hydroxybutyrate (GHB)-dependence in Dutch Addiction Treatment Centers (ATCs) in comparison with other addictions. A cohort-study using nationwide administrative data from regular Dutch ATCs associated with the Dutch National Alcohol and Drugs Information System (LADIS), covering an estimated 95% of ATCs. We selected in- and out-patients with alcohol, drug and/or behavioral addictions with a first treatment episode in 2008-2011 and consecutive treatments until 2013 (n=71,679). Patients still in treatment at that date (n=3686; 5.1%), forensic patients (n=1949; 2.7%) and deceased patients (n=570; 0.8%) were excluded, leaving 65,474 patients (91.3%). Of those, 596 (0.9%) patients had GHB dependence. We analyzed number of treatment contacts, treatment duration, admissions and admission duration of the first treatment episode, and re-enrollment (defined as having started a second treatment episode in the study period). GHB-dependent patients showed the highest number of treatment contacts, duration of treatment and chance of being admitted. Re-enrollment rates were 2-5 times higher in GHB-dependent patients than other patients with adjusted HR of other addictions ranging from 0.18 (95% confidence interval [CI]: 0.15-0.21) to 0.53 (95% CI: 0.47-0.61). This study demonstrates high levels of treatment consumption and high rates of treatment re-enrollment in GHB-dependent patients. These findings highlight the urgency of developing effective relapse prevention interventions for GHB-dependent patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Getting Treatment for ADHD

    Medline Plus

    Full Text Available ... Youth Resources Child and Adolescent Psychiatrist Finder Getting Treatment Without treatment, a child with ADHD may fall behind in ... driving infractions. The good news is that effective treatment is available . With the right medical treatment, children ...

  17. Sleep disturbances in treatment-seeking OCD-patients: Changes after concentrated exposure treatment.

    Science.gov (United States)

    Nordahl, Håkon; Havnen, Audun; Hansen, Bjarne; Öst, Lars-Göran; Kvale, Gerd

    2018-04-01

    Research indicates that patients with Obsessive Compulsive Disorder (OCD) frequently suffer from comorbid sleep difficulties, and that these difficulties often are not clinically recognized and diagnosed. There has been limited research investigating if comorbid sleep difficulties impair treatment outcome for OCD and if the sleep difficulties change following OCD-treatment. Thirty-six patients with obsessive compulsive disorder underwent concentrated exposure treatment delivered in a group over four consecutive days and were assessed with measures of OCD, depressive symptoms and sleep disturbance at three different time points (pre, post and 6 months follow-up). The sample was characterized by a high degree of comorbidity with other psychiatric disorders. At pre-treatment nearly 70% of the patients reported sleep difficulties indicative of primary insomnia. The results showed that patients had large reductions of OCD-symptoms as well as significant improvements in sleep disturbance assessed after treatment, and that these improvements were maintained at follow-up. Sleep disturbance did not impair treatment outcome, on the contrary patients with higher degree of sleep disturbance at pre-treatment had better outcome on OCD-symptoms after treatment. The results indicated that the majority of the OCD sample suffered from sleep disturbances and that these sleep disturbances were significantly reduced following adequate treatment of OCD without specific sleep interventions. However, a proportion of the patients suffered from residual symptoms of insomnia after treatment. © 2017 Scandinavian Psychological Associations and John Wiley & Sons Ltd.

  18. Treatment selection in a randomized clinical trial via covariate-specific treatment effect curves.

    Science.gov (United States)

    Ma, Yunbei; Zhou, Xiao-Hua

    2017-02-01

    For time-to-event data in a randomized clinical trial, we proposed two new methods for selecting an optimal treatment for a patient based on the covariate-specific treatment effect curve, which is used to represent the clinical utility of a predictive biomarker. To select an optimal treatment for a patient with a specific biomarker value, we proposed pointwise confidence intervals for each covariate-specific treatment effect curve and the difference between covariate-specific treatment effect curves of two treatments. Furthermore, to select an optimal treatment for a future biomarker-defined subpopulation of patients, we proposed confidence bands for each covariate-specific treatment effect curve and the difference between each pair of covariate-specific treatment effect curve over a fixed interval of biomarker values. We constructed the confidence bands based on a resampling technique. We also conducted simulation studies to evaluate finite-sample properties of the proposed estimation methods. Finally, we illustrated the application of the proposed method in a real-world data set.

  19. First treatment contact for ADHD: predictors of and gender differences in treatment seeking.

    Science.gov (United States)

    Dakwar, Elias; Levin, Frances R; Olfson, Mark; Wang, Shuai; Kerridge, Bradley; Blanco, Carlos

    2014-12-01

    For attention-deficit hyperactivity disorder (ADHD), treatment seeking is a critical first step in treatment initiation and remains insufficiently understood. The aims of this study were to estimate ADHD treatment-seeking probabilities over the lifetime and to identify predictors of treatment seeking for ADHD separately for males and females. Data were drawn from 2001 to 2005 as part of the National Epidemiologic Survey on Alcohol and Related Conditions, a two-wave face-to-face survey conducted by the National Institute on Alcohol Abuse and Alcoholism (N=34,653). The lifetime cumulative probability of ADHD treatment seeking was estimated at 55%. Males identifying as African American, with less than 12 years of education, or paranoid personality disorder or in an older cohort (>30 years old) at the time of interview were more likely to experience delays, whereas males with comorbid alcohol dependence, dysthymic disorder, borderline personality disorder, or histrionic personality disorder were less likely. Among females, older age (>44 years) was the only predictor of a delay to first treatment seeking, whereas bipolar disorder was associated with more rapid treatment seeking. Age of onset had opposite effects on treatment-seeking delays by gender; males but not females with early-onset ADHD were more likely to experience treatment-seeking delays. A large proportion of persons with ADHD do not seek treatment. Furthermore, treatment seeking by males was affected by a greater number of identifiable characteristics, suggesting that males might be more responsive to efforts directed toward expediting treatment entry. Future research should explore how to facilitate early access to treatment for individuals with ADHD.

  20. Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy.

    Science.gov (United States)

    Rault, Erwann; Lacornerie, Thomas; Dang, Hong-Phuong; Crop, Frederik; Lartigau, Eric; Reynaert, Nick; Pasquier, David

    2016-02-27

    Accelerated partial breast irradiation (APBI) is a new breast treatment modality aiming to reduce treatment time using hypo fractionation. Compared to conventional whole breast irradiation that takes 5 to 6 weeks, APBI is reported to induce worse cosmetic outcomes both when using three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT). These late normal tissue effects may be attributed to the dose volume effect because a large portion of the non-target breast tissue volume (NTBTV) receives a high dose. In the context of APBI, non-coplanar beams could spare the NTBTV more efficiently. This study evaluates the dosimetric benefit of using the Cyberknife (CK) for APBI in comparison to IMRT (Tomotherapy) and three dimensional conformal radiotherapy (3D-CRT). The possibility of using surgical clips, implanted during surgery, to track target movements is investigated first. A phantom of a female thorax was designed in-house using the measurements of 20 patients. Surgical clips of different sizes were inserted inside the breast. A treatment plan was delivered to the mobile and immobile phantom. The motion compensation accuracy was evaluated using three radiochromic films inserted inside the breast. Three dimensional conformal radiotherapy (3D-CRT), Tomotherapy (TOMO) and CK treatment plans were calculated for 10 consecutive patients who received APBI in Lille. To ensure a fair comparison of the three techniques, margins applied to the CTV were set to 10 mm. However, a second CK plan was prepared using 3 mm margins to evaluate the benefits of motion compensation. Only the larger clips (VITALITEC Medium-Large) could be tracked inside the larger breast (all gamma indices below 1 for 1 % of the maximum dose and 1 mm). All techniques meet the guidelines defined in the NSABP/RTOG and SHARE protocols. As the applied dose volume constraints are very strong, insignificant dosimetric differences exist between techniques regarding the PTV

  1. Multistage stereotactic radiosurgery for large cerebral arteriovenous malformations using the Gamma Knife platform.

    Science.gov (United States)

    Ding, Chuxiong; Hrycushko, Brian; Whitworth, Louis; Li, Xiang; Nedzi, Lucien; Weprin, Bradley; Abdulrahman, Ramzi; Welch, Babu; Jiang, Steve B; Wardak, Zabi; Timmerman, Robert D

    2017-10-01

    Radiosurgery is an established technique to treat cerebral arteriovenous malformations (AVMs). Obliteration of larger AVMs (> 10-15 cm 3 or diameter > 3 cm) in a single session is challenging with current radiosurgery platforms due to toxicity. We present a novel technique of multistage stereotactic radiosurgery (SRS) for large intracranial arteriovenous malformations (AVM) using the Gamma Knife system. Eighteen patients with large (> 10-15 cm 3 or diameter > 3 cm) AVMs, which were previously treated using a staged SRS technique on the Cyberknife platform, were retrospectively selected for this study. The AVMs were contoured and divided into 3-8 subtargets to be treated sequentially in a staged approach at half to 4 week intervals. The prescription dose ranged from 15 Gy to 20 Gy, depending on the subtarget number, volume, and location. Gamma Knife plans using multiple collimator settings were generated and optimized. The coordinates of each shot from the initial plan covering the total AVM target were extracted based on their relative positions within the frame system. The shots were regrouped based on their location with respect to the subtarget contours to generate subplans for each stage. The delivery time of each shot for a subtarget was decay corrected with 60 Co for staging the treatment course to generate the same dose distribution as that planned for the total AVM target. Conformality indices and dose-volume analysis were performed to evaluate treatment plans. With the shot redistribution technique, the composite dose for the multistaged treatment of multiple subtargets is equivalent to the initial plan for total AVM target. Gamma Knife plans resulted in an average PTV coverage of 96.3 ± 0.9% and a PITV of 1.23 ± 0.1. The resulting Conformality indices, V 12Gy and R 50 dose spillage values were 0.76 ± 0.05, 3.4 ± 1.8, and 3.1 ± 0.5 respectively. The Gamma Knife system can deliver a multistaged conformal dose to treat large AVMs when correcting for

  2. Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Rault, Erwann; Lacornerie, Thomas; Dang, Hong-Phuong; Crop, Frederik; Lartigau, Eric; Reynaert, Nick; Pasquier, David

    2016-01-01

    Accelerated partial breast irradiation (APBI) is a new breast treatment modality aiming to reduce treatment time using hypo fractionation. Compared to conventional whole breast irradiation that takes 5 to 6 weeks, APBI is reported to induce worse cosmetic outcomes both when using three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT). These late normal tissue effects may be attributed to the dose volume effect because a large portion of the non-target breast tissue volume (NTBTV) receives a high dose. In the context of APBI, non-coplanar beams could spare the NTBTV more efficiently. This study evaluates the dosimetric benefit of using the Cyberknife (CK) for APBI in comparison to IMRT (Tomotherapy) and three dimensional conformal radiotherapy (3D-CRT). The possibility of using surgical clips, implanted during surgery, to track target movements is investigated first. A phantom of a female thorax was designed in-house using the measurements of 20 patients. Surgical clips of different sizes were inserted inside the breast. A treatment plan was delivered to the mobile and immobile phantom. The motion compensation accuracy was evaluated using three radiochromic films inserted inside the breast. Three dimensional conformal radiotherapy (3D-CRT), Tomotherapy (TOMO) and CK treatment plans were calculated for 10 consecutive patients who received APBI in Lille. To ensure a fair comparison of the three techniques, margins applied to the CTV were set to 10 mm. However, a second CK plan was prepared using 3 mm margins to evaluate the benefits of motion compensation. Only the larger clips (VITALITEC Medium-Large) could be tracked inside the larger breast (all gamma indices below 1 for 1 % of the maximum dose and 1 mm). All techniques meet the guidelines defined in the NSABP/RTOG and SHARE protocols. As the applied dose volume constraints are very strong, insignificant dosimetric differences exist between techniques regarding the PTV

  3. Pharmacological treatment of sexual offenders in German outpatient treatment centers.

    Science.gov (United States)

    Turner, Daniel; Gregório Hertz, Priscilla; Sauter, Julia; Briken, Peer; Rettenberger, Martin

    2018-05-04

    In Germany, depending on a sexual offender's culpability and the severity of the offence, he/she can be placed either in the forensic-psychiatric or the correctional system. Numbers related to the pharmacological treatment of sexual offenders for the correctional system are missing so far. In sexual offenders, the pharmacological treatment of paraphilic disorders is of special importance. The present study aimed at assessing the prevalence of pharmacological sexual offender treatment in German outpatient treatment centers supervising mainly clients from the correctional sector. An online questionnaire was sent to 112 outpatient treatment centers and 21 provided data relevant for the present study. The included institutions reported about a total of 813 sexual offenders, of whom 200 (24.6%) were treated with pharmacological agents, most frequently antipsychotics (14.8%) and selective-serotonin-reuptake-inhibitors (7.1%). Of the total sample, 26.7% of sexual offenders were diagnosed with a paraphilic - mainly with a pedophilic - disorder. Only 2% were treated with androgen-deprivation therapy. Compared with forensic-psychiatric institutions, only a minority of sexual offenders are treated with medication specifically addressing paraphilic symptomatology. However, the prevalence of paraphilic disorders found in the present study suggests that pharmacological treatment of paraphilic fantasies and behaviors could be of great importance in the correctional sector as well.

  4. Finding the Right Treatment for Achalasia Treatment: Risks, Efficacy, Complications.

    Science.gov (United States)

    Moonen, An; Boeckxstaens, Guy

    2016-12-01

    Achalasia is a primary esophageal motor disorder of the esophagus that is characterized by the absence of esophageal peristalsis and a failure of the lower esophageal sphincter (LES) to relax upon swallowing. The defective relaxation leads to symptoms of dysphagia for solids and liquids, regurgitation, aspiration, chest pain, and weight loss. Achalasia is believed to result from a selective loss of enteric inhibitory neurons, most likely due to an autoimmune phenomenon in genetic susceptible individuals. As there is no curative treatment for achalasia, treatment is confined to disruption of the LES to improve bolus passage. The two most commonly used treatment modalities available are the endoscopic pneumodilation (PD) and the surgical laparoscopic Heller myotomy (LHM). A recent European randomized controlled trial showed that both treatment modalities have comparable success rates after a follow-up of at least 5 years. In view of these data, both treatments can be used as an initial therapy in achalasia and the choice should be based on the expertise available. Recently, a new endoscopic technique, peroral endoscopic myotomy (POEM), has been introduced with excellent short-term success rates. However, longer follow-up and data from randomized controlled trials are needed before accepting this technique as a new treatment option for achalasia in clinical practice.

  5. Beyond Fuel Treatment Effectiveness: Characterizing Interactions between Fire and Treatments in the US

    Directory of Open Access Journals (Sweden)

    Kevin Barnett

    2016-10-01

    Full Text Available In the United States, fuel reduction treatments are a standard land management tool to restore the structure and composition of forests that have been degraded by past management. Although treatments can have multiple purposes, their principal objective is to create landscape conditions where wildland fire can be safely managed to help achieve long-term land management goals. One critique is that fuel treatment benefits are unlikely to transpire due to the low probability that treated areas will be burned by a subsequent fire within a treatment’s lifespan, but little quantitative information exists to corroborate this argument. We summarized the frequency, extent, and geographic variation of fire and fuel treatment interactions on federal lands within the conterminous United States (CONUS. We also assessed how the encounters between fuel treatments and fires varied with treatment size, treatment age, and number of times treated. Overall, 6.8% of treatment units evaluated were encountered by a subsequent fire during the study period, though this rate varied among ecoregions across the CONUS. Larger treatment units were more likely to be encountered by a fire, and treatment units were most frequently burned within one year of the most recent treatment, the latter of which is likely because of ongoing maintenance of existing treatments. Our results highlight the need to identify and prioritize additional opportunities to reduce fuel loading and fire risk on the millions of hectares of federal lands in the CONUS that are in need of restoration.

  6. Treatment Fidelity: Its Importance and Reported Frequency in Aphasia Treatment Studies

    Science.gov (United States)

    Hinckley, Jacqueline J.; Douglas, Natalie F.

    2013-01-01

    Purpose: Treatment fidelity is a measure of the reliability of the administration of an intervention in a treatment study. It is an important aspect of the validity of a research study, and it has implications for the ultimate implementation of evidence-supported interventions in typical clinical settings. Method: Aphasia treatment studies…

  7. The Hybrid Treatment Process for mixed radioactive and hazardous waste treatment

    International Nuclear Information System (INIS)

    Ross, W.A.; Kindle, C.H.

    1992-06-01

    This paper describes a new process for treating mixed hazardous and radioactive waste, commonly called mixed waste. The process is called the Hybrid Treatment Process (HTP), so named because it is built on the 20 years of experience with vitrification of wastes in melters, and the 12 years of experience with treatment of wastes by the in situ vitrification (ISV) process. It also uses techniques from several additional technologies. Mixed wastes are being generated by both the US Department of Energy (DOE) and by commercial sources. The wastes are those that contain both a hazardous waste regulated under the US Environmental Protection Agency's (EPA) Resource, Conservation, and Recovery Act (RCRA) regulations and a radioactive waste with source, special nuclear, or byproduct materials. The dual regulation of the wastes increases the complexity of the treatment, handling, and storage of the waste. The DOE is the largest holder and generator of mixed waste. Its mixed wastes are classified as either high-level, transuranic (TRU), or low-level waste (LLW). High-level mixed wastes will be treated in vitrification plants. Transuranic wastes may be disposed of without treatment by obtaining a no-migration variance from the EPA. Lowlevel wastes, however, will require treatment, but treatment systems with sufficient capacity are not yet available to DOE. Various facilities are being proposed for the treatment of low-level waste. The concept described in this paper represents one option for establishing that treatment capacity

  8. Land Treatment Digital Library

    Science.gov (United States)

    Pilliod, David S.; Welty, Justin L.

    2013-01-01

    The Land Treatment Digital Library (LTDL) was created by the U.S. Geological Survey to catalog legacy land treatment information on Bureau of Land Management lands in the western United States. The LTDL can be used by federal managers and scientists for compiling information for data-calls, producing maps, generating reports, and conducting analyses at varying spatial and temporal scales. The LTDL currently houses thousands of treatments from BLM lands across 10 states. Users can browse a map to find information on individual treatments, perform more complex queries to identify a set of treatments, and view graphs of treatment summary statistics.

  9. Accelerated treatment protocols: full arch treatment with interim and definitive prostheses.

    Science.gov (United States)

    Drago, Carl

    2012-01-01

    With the advent of titanium, root form implants and osseointegration, dental treatment has undergone a metamorphosis in recent years. These new techniques enable dentists to provide anchorage for various kinds of prostheses that improve masticatory function, esthetics, and comfort for patients. Implant treatment protocols have been improved relative to implant macro- and micro-geometries, surgical and prosthetic components, and treatment times. Over the past 20 years, immediate occlusal function (also known as loading) has been established as a predictable treatment modality, provided certain specific criteria are met. In many cases, edentulous patients, crippled by the loss of their teeth, can undergo outpatient surgical and prosthetic procedures and return to a masticatory function that is near normal--sometimes after only one day of surgical and prosthetic treatment. This treatment option is also available for patients with advanced, generalized periodontal disease. Computer-assisted design/Computer-assisted manufacturing (CAD/CAM) has transformed how dental prostheses are made, offering improved accuracy, longevity, and biocompatibility; along with reduced labor costs and fewer complications than casting technologies. This article reviews the principles associated with immediate occlusal loading and illustrates one specific accelerated prosthodontic treatment protocol used to treat edentulous and partially edentulous patients with interim and definitive prostheses.

  10. Treatment preference in hypochondriasis.

    Science.gov (United States)

    Walker, J; Vincent, N; Furer, P; Cox, B; Kjernisted, K

    1999-12-01

    Promising cognitive-behavioral and medication treatments for hypochondriasis are in the early stages of evaluation. Little is known about the treatment preferences and opinions of individuals seeking help for this problem. In this exploratory study, 23 volunteers from the community with a DSM-IV diagnosis of hypochondriasis were recruited through a newspaper advertisement. Participants were presented with a survey which included balanced descriptions of both a medication and a cognitive-behavioral treatment for intense illness concerns (hypochondriasis). The brief descriptions of the treatments discussed the time commitment required as well as the major advantages and disadvantages of each. Results showed that, relative to medication treatment, cognitive-behavioral treatment was predicted to be more effective in both the short and long terms and was rated as more acceptable. Psychological treatment was indicated as the first choice by 74% of respondents, medication by 4%, and 22% indicated an equal preference. Forty-eight percent of respondents would only accept the psychological treatment.

  11. Endovascular treatment of acute basilar artery occlusion: time to treatment is crucial

    International Nuclear Information System (INIS)

    Dorňák, T.; Herzig, R.; Kuliha, M.; Havlíček, R.; Školoudík, D.; Šaňák, D.; Köcher, M.; Procházka, V.; Lacman, J.; Charvát, F.; Krajina, A.

    2015-01-01

    Aim: To evaluate the safety and efficacy of multimodal endovascular treatment (EVT) of acute basilar artery occlusion (BAO), including bridging therapy [intravenous thrombolysis (IVT) with subsequent EVT], to compare particular EVT techniques and identify predictors of clinical outcome. Materials and methods: This retrospective, multi-centre study comprised 72 acute ischaemic stroke patients (51 males; mean age 59.1 ± 13.3 years) with radiologically confirmed BAO. The following data were collected: baseline characteristics, risk factors, pre-event antithrombotic treatment, neurological deficit at time of treatment, localization of occlusion, time to therapy, recanalization rate, post-treatment imaging findings. Thirty- and 90-day outcomes were evaluated using the modified Rankin scale with a good clinical outcome defined as 0–3 points. Results: Successful recanalization was achieved in 94.4% patients. Stepwise binary logistic regression analysis identified the presence of arterial hypertension (OR = 0.073 and OR = 0.067, respectively), National Institutes of Health Stroke Scale (NIHSS) at the time of treatment (OR = 0,829 and OR = 0.864, respectively), and time to treatment (OR = 0.556 and OR = 0.502, respectively) as significant independent predictors of 30- and 90-day clinical outcomes. Conclusion: Data from this multicentre study showed that multimodal EVT was an effective recanalization method in acute BAO. Bridging therapy shortens the time to treatment, which was identified as the only modifiable outcome predictor. - Highlights: • Various treatments are being used in recanalization of basilar artery occlusion. • Multimodal endovascular treatment is an effective recanalization method. • Time-to-treatment is the only modifiable outcome predictor. • Bridging therapy shortens time-to-treatment. • Arterial hypertension, neurologic deficit are associated with poor outcome

  12. Adjunctive steroid treatment

    DEFF Research Database (Denmark)

    Korshin, André; Køster-Rasmussen, Rasmus; Meyer, Christian N

    2007-01-01

    Our objective was to evaluate local guidelines regarding early steroid treatment in adult community acquired bacterial meningitis, and assess the actual treatment given and its correlation to clinical outcome. Patient outcome was obtained retrospectively from the medical records of 210 adults...... admitted to 47 hospitals in Denmark during 2002-2004 (population 5.4 million) and was combined with results from a questionnaire regarding treatment guidelines in these hospitals. In 36 of 47 departments responding to the questionnaire, 21 recommended early steroid treatment, but none did so initially...... during 2002. Early steroid treatment was given to 15% of patients and was given more often when recommended locally (41% vs 11%, OR=5.7 (2.4-13.5)). Unfavourable outcome was demonstrated rarely in patients treated with early steroids compared to the non-steroid group (17% vs 42%, p

  13. Waste treatment

    International Nuclear Information System (INIS)

    Davies, D.; Hooper, E.W.

    1981-01-01

    In the treatment of wastes, such as liquid radioactive effluents, it is known to remove radionuclides by successive in situ precipitation of cobalt sulphide, an hydroxide, barium sulphate and a transition element ferrocyanide, followed by separation of the thereby decontaminated effluent. In this invention, use is made of precipitates such as obtained above in the treatment of further fresh liquid radioactive effluent, when it is found that the precipitates have additional capacity for extracting radionuclides. The resulting supernatant liquor may then be subjected to a further precipitation treatment such as above. Decontamination factors for radionuclides of Ce, Ru, Sr and Cs have been considerably enhanced. (author)

  14. Neuroimaging in aphasia treatment research: Standards for establishing the effects of treatment

    Science.gov (United States)

    Kiran, Swathi; Ansaldo, Ana; Bastiaanse, Roelien; Cherney, Leora R.; Howard, David; Faroqi-Shah, Yasmeen; Meinzer, Marcus; Thompson, Cynthia K

    2012-01-01

    The goal of this paper is to discuss experimental design options available for establishing the effects of treatment in studies that aim to examine the neural mechanisms associated with treatment-induced language recovery in aphasia, using functional magnetic resonance imaging (fMRI). We present both group and single-subject experimental or case-series design options for doing this and address advantages and disadvantages of each. We also discuss general components of and requirements for treatment research studies, including operational definitions of variables, criteria for defining behavioral change and treatment efficacy, and reliability of measurement. Important considerations that are unique to neuroimaging-based treatment research are addressed, pertaining to the relation between the selected treatment approach and anticipated changes in language processes/functions and how such changes are hypothesized to map onto the brain. PMID:23063559

  15. The impact of treatment complexity and computer-control delivery technology on treatment delivery errors

    International Nuclear Information System (INIS)

    Fraass, Benedick A.; Lash, Kathy L.; Matrone, Gwynne M.; Volkman, Susan K.; McShan, Daniel L.; Kessler, Marc L.; Lichter, Allen S.

    1998-01-01

    Purpose: To analyze treatment delivery errors for three-dimensional (3D) conformal therapy performed at various levels of treatment delivery automation and complexity, ranging from manual field setup to virtually complete computer-controlled treatment delivery using a computer-controlled conformal radiotherapy system (CCRS). Methods and Materials: All treatment delivery errors which occurred in our department during a 15-month period were analyzed. Approximately 34,000 treatment sessions (114,000 individual treatment segments [ports]) on four treatment machines were studied. All treatment delivery errors logged by treatment therapists or quality assurance reviews (152 in all) were analyzed. Machines 'M1' and 'M2' were operated in a standard manual setup mode, with no record and verify system (R/V). MLC machines 'M3' and 'M4' treated patients under the control of the CCRS system, which (1) downloads the treatment delivery plan from the planning system; (2) performs some (or all) of the machine set up and treatment delivery for each field; (3) monitors treatment delivery; (4) records all treatment parameters; and (5) notes exceptions to the electronically-prescribed plan. Complete external computer control is not available on M3; therefore, it uses as many CCRS features as possible, while M4 operates completely under CCRS control and performs semi-automated and automated multi-segment intensity modulated treatments. Analysis of treatment complexity was based on numbers of fields, individual segments, nonaxial and noncoplanar plans, multisegment intensity modulation, and pseudoisocentric treatments studied for a 6-month period (505 patients) concurrent with the period in which the delivery errors were obtained. Treatment delivery time was obtained from the computerized scheduling system (for manual treatments) or from CCRS system logs. Treatment therapists rotate among the machines; therefore, this analysis does not depend on fixed therapist staff on particular

  16. [Management of opioid maintenance treatments when analgesic treatments are required].

    Science.gov (United States)

    Laprevote, Vincent; Geoffroy, Pierre A; Rolland, Benjamin; Leheup, Benoît F; Di Patrizio, Paolo; Cottencin, Olivier; Schwan, Raymund

    2013-01-01

    Opioid maintenance treatments (OMT) reduce illicit opiate use and its associated risks. They are often prescribed on a long-term basis. Physiological changes induced by long-term OMT may cause hyperalgesia and cross-tolerance to opioid agonists, which suggests that the dosage of analgesic treatment should be modified in cases of acute pain, especially when an opioid-based analgesia is required. When treatment with analgesics is necessary, OMT must be maintained, except in exceptional cases. If a split-dosing schedule is temporarily employed during OMT, the daily dosage should not be increased for analgesic purposes. Analgesic treatment must be managed differently in case of treatment with buprenorphine or methadone. With buprenorphine, non-opioid analgesics should be introduced first, if possible. If this strategy is inefficient or contraindicated, a temporary or definitive switch to methadone should be considered. In the case of methadone-based OMT, opioid analgesics should be added directly and the dosage should be adapted according to the level of pain reported by the patient. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  17. Treatment 2.0: catalyzing the next phase of treatment, care and support.

    Science.gov (United States)

    Duncombe, Chris; Ball, Andrew; Passarelli, Carlos; Hirnschall, Gottfried

    2013-01-01

    This review provides an update on the WHO/UNAIDS Treatment 2.0 strategy by reviewing the documents and technical updates issued under the initiative. Launched in 2010, this global initiative provides a framework for the continued scale-up of access to HIV care and treatment. WHO has prioritized once daily fixed-dose combination as the preferred antiretroviral (ARV) regimen to initiate HIV treatment, paving the way for programmatic simplification, with reduced toxicity and improved adherence. WHO also recommends the use of point-of-care diagnostics, with CD4 cell count technologies being implemented in the field and progress towards improving access to simplified viral load testing. The strategy also seeks mechanisms that can contribute to reducing treatment costs, such as pooled commodity procurement and public health-oriented licensing approaches. Improved service delivery, specifically through decentralization, task shifting, integration and community mobilization also has the potential to reduce costs and improve access. Support to countries has been provided through the timely release of a series of programmatic and technical updates on specific treatment-related topics. The Treatment 2.0 strategy articulates how innovation and greater efficiency can make HIV care and treatment more accessible and affordable, and guide treatment and prevention scale-up.

  18. Effects of unplanned treatment interruptions on HIV treatment failure– results from TAHOD

    Science.gov (United States)

    Jiamsakul, Awachana; Kerr, Stephen J.; Ng, Oon Tek; Lee, Man Po; Chaiwarith, Romanee; Yunihastuti, Evy; Van Nguyen, Kinh; Pham, Thuy Thanh; Kiertiburanakul, Sasisopin; Ditangco, Rossana; Saphonn, Vonthanak; Sim, Benedict L. H.; Merati, Tuti Parwati; Wong, Wingwai; Kantipong, Pacharee; Zhang, Fujie; Choi, Jun Yong; Pujari, Sanjay; Kamarulzaman, Adeeba; Oka, Shinichi; Mustafa, Mahiran; Ratanasuwan, Winai; Petersen, Boondarika; Law, Matthew; Kumarasamy, Nagalingeswaran

    2016-01-01

    Objectives Treatment interruptions (TI) of combination antiretroviral therapy (cART) are known to lead to unfavourable treatment outcomes but do still occur in resource-limited settings. We investigated the effects of TI associated with adverse events (AEs) and non-AE-related reasons, including their durations, on treatment failure after cART resumption in HIV-infected individuals in Asia. Methods Patients initiating cART between 2006-2013 were included. TI was defined as stopping cART for >1 day. Treatment failure was defined as confirmed virological, immunological or clinical failure. Time to treatment failure during cART was analysed using Cox regression, not including periods off treatment. Co-variables with p30 days were associated with failure (31-180 days HR=2.66, 95%CI (1.70-4.16); 181-365 days HR=6.22, 95%CI (3.26-11.86); and >365 days HR=9.10, 95% CI (4.27-19.38), all pfailure. If TI is unavoidable, its duration should be minimised to reduce the risk of failure after treatment resumption. PMID:26950901

  19. MO-G-BRE-04: Automatic Verification of Daily Treatment Deliveries and Generation of Daily Treatment Reports for a MR Image-Guided Treatment Machine

    International Nuclear Information System (INIS)

    Yang, D; Li, X; Li, H; Wooten, H; Green, O; Rodriguez, V; Mutic, S

    2014-01-01

    Purpose: Two aims of this work were to develop a method to automatically verify treatment delivery accuracy immediately after patient treatment and to develop a comprehensive daily treatment report to provide all required information for daily MR-IGRT review. Methods: After systematically analyzing the requirements for treatment delivery verification and understanding the available information from a novel MR-IGRT treatment machine, we designed a method to use 1) treatment plan files, 2) delivery log files, and 3) dosimetric calibration information to verify the accuracy and completeness of daily treatment deliveries. The method verifies the correctness of delivered treatment plans and beams, beam segments, and for each segment, the beam-on time and MLC leaf positions. Composite primary fluence maps are calculated from the MLC leaf positions and the beam-on time. Error statistics are calculated on the fluence difference maps between the plan and the delivery. We also designed the daily treatment delivery report by including all required information for MR-IGRT and physics weekly review - the plan and treatment fraction information, dose verification information, daily patient setup screen captures, and the treatment delivery verification results. Results: The parameters in the log files (e.g. MLC positions) were independently verified and deemed accurate and trustable. A computer program was developed to implement the automatic delivery verification and daily report generation. The program was tested and clinically commissioned with sufficient IMRT and 3D treatment delivery data. The final version has been integrated into a commercial MR-IGRT treatment delivery system. Conclusion: A method was developed to automatically verify MR-IGRT treatment deliveries and generate daily treatment reports. Already in clinical use since December 2013, the system is able to facilitate delivery error detection, and expedite physician daily IGRT review and physicist weekly chart

  20. Treatment Response to an Intensive Summer Treatment Program for Adolescents with ADHD

    Science.gov (United States)

    Sibley, Margaret H.; Smith, Bradley H.; Evans, Steven W.; Pelham, William E.; Gnagy, Elizabeth M.

    2012-01-01

    Objective: There are presently almost no empirically validated treatments for adolescents with ADHD. However, in childhood, behavioral treatments for ADHD typically include behavioral parent training, classroom interventions, and intensive child-directed interventions. Method: The present investigation examines treatment gains following an 8-week…

  1. Water Treatment Group

    Data.gov (United States)

    Federal Laboratory Consortium — This team researches and designs desalination, water treatment, and wastewater treatment systems. These systems remediate water containing hazardous c hemicals and...

  2. Preventive Migraine Treatment

    Science.gov (United States)

    Silberstein, Stephen D.

    2015-01-01

    Purpose of Review: This article reviews the evidence base for the preventive treatment of migraine. Recent Findings: Evidence-based guidelines for the preventive treatment of migraine have recently been published by the American Academy of Neurology (AAN) and the Canadian Headache Society (CHS), providing valuable guidance for clinicians. Strong evidence exists to support the use of metoprolol, timolol, propranolol, divalproex sodium, sodium valproate, and topiramate for migraine prevention, according to the AAN. Based on best available evidence, adverse event profile, and expert consensus, topiramate, propranolol, nadolol, metoprolol, amitriptyline, gabapentin, candesartan, Petasites (butterbur), riboflavin, coenzyme Q10, and magnesium citrate received a strong recommendation for use from the CHS. Summary: Migraine preventive drug treatments are underutilized in clinical practice. Principles of preventive treatment are important to improve compliance, minimize side effects, and improve patient outcomes. Choice of preventive treatment of migraine should be based on the presence of comorbid and coexistent illness, patient preference, reproductive potential and planning, and best available evidence. PMID:26252585

  3. Endoscopic root canal treatment.

    Science.gov (United States)

    Moshonov, Joshua; Michaeli, Eli; Nahlieli, Oded

    2009-10-01

    To describe an innovative endoscopic technique for root canal treatment. Root canal treatment was performed on 12 patients (15 teeth), using a newly developed endoscope (Sialotechnology), which combines an endoscope, irrigation, and a surgical microinstrument channel. Endoscopic root canal treatment of all 15 teeth was successful with complete resolution of all symptoms (6-month follow-up). The novel endoscope used in this study accurately identified all microstructures and simplified root canal treatment. The endoscope may be considered for use not only for preoperative observation and diagnosis but also for active endodontic treatment.

  4. Treatment of thyroid cancer

    International Nuclear Information System (INIS)

    Voronetskij, I.B.

    1990-01-01

    Peculiarities of thyroid cancer, producing direct influence on selection of treatment procedure are enumerated. It is shown that surgical treatment is the determining way of treatment, which is supplemented with hormonotherapy in case of differentiated forms of the tumor. In case of anaplasia cancer, sarcomas, propagation of tumor beyond the limits of the organ, inoperable processes, treatment of recurrences and functional inactivity of bone metastases the remote control gamma-therapy should be performed. Therapy by radioactive iodine is shown for the treatment of remote iodine-concentrating metastases for devitalization of residual thyroid tissue after thyroidectomy

  5. Hazardous Waste Treatment Facility and skid-mounted treatment systems at Los Alamos

    International Nuclear Information System (INIS)

    Lussiez, G.W.; Zygmunt, S.J.

    1994-01-01

    To centralize treatment, storage, and areas for hazardous wastes, Los Alamos National Laboratory has designed a 1115 m2 hazardous waste treatment facility. The facility will house a treatment room for each of four kinds of wastes: nonradioactive characteristic wastes, nonradioactive listed wastes, radioactive characteristic wastes, and radioactive listed wastes. The facility will be used for repacking labpacks; bulking small organic waste volumes; processing scintillation vials; treating reactives such as lithium hydride and pyrophoric uranium; treating contaminated solids such as barium sand; treating plating wastes and other solutions with heavy metals and oxidizing organics: Separate treatment rooms will allow workers to avoid mixing waste types and prevent cross-contamination. The ventilation air from the treatment areas may contain hazardous or radioactive dust. Gas may also leak from process equipment. The gas treatment process includes separating solids and gases and neutralization or adsorption of the hazardous gases. The ventilation air from each room will first be filtered before being scrubbed in a common gas caustic scrubber on an outside pad. There are two levels of exhaust in each treatment room, one for heavy gases and another for light gases. Several features help mitigate or eliminate hazards due to spills and releases: each treatment room is sealed and under slight negative pressure; each room has its own HEPA filtration; to avoid mixing of incompatible wastes and reagents, portable individual spill-containment trays are used for skids, to limit the danger of spills, the waste is directly transferred from outside storage to the treatment room; to mitigate the consequences of a gas release in the room, mobile hoods are connected to the exhaust-air treatment system; the floor, walls, ceilings, fixtures, ducts, and piping are made of acid-resistant material or are coated

  6. Treatment Option Overview (Kaposi Sarcoma)

    Science.gov (United States)

    ... Treatment Childhood Vascular Tumors Treatment Research Kaposi Sarcoma Treatment (PDQ®)–Patient Version General Information About Kaposi Sarcoma ... Certain factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment ...

  7. Domestic Violence Offender Treatment and Multidisciplinary Treatment Teams: The Role of "Treatment" Victim Advocates.

    Science.gov (United States)

    Richards, Tara N; Gover, Angela R

    2018-03-01

    In Colorado, "treatment victim advocates" (TVAs) serve alongside providers and probation/parole officers on "multidisciplinary treatment teams" (MTTs) to oversee domestic violence offender's treatment. Although this model provides an opportunity for victim safety concerns to be heard, the utility of using victim advocates as advisors regarding interventions for domestic violence offenders has yet to be studied. Using survey data and narrative responses from TVAs ( N = 37), the current study examines the challenges and opportunities TVAs face while serving on MTTs. Results suggest that, overall, TVAs are successful in communicating with other members of the MTT, are confident that their perspectives are valued in the offender decision-making process, and are able to provide a wide variety of services and referrals to the victims with whom they are engaged. Implications and recommendations for the Colorado model as well as correctional professionals managing domestic violence offenders internationally are presented and discussed.

  8. Association between root resorption incident to orthodontic treatment and treatment factors.

    Science.gov (United States)

    Motokawa, Masahide; Sasamoto, Tomoko; Kaku, Masato; Kawata, Toshitsugu; Matsuda, Yayoi; Terao, Akiko; Tanne, Kazuo

    2012-06-01

    The purpose of this study was to clarify the prevalence and degree of root resorption induced by orthodontic treatment in association with treatment factors. The files of 243 patients (72 males and 171 females) aged 9-51 years were randomly selected from subjects treated with multi-bracket appliances. The severity of root resorption was classified into five categories on radiographs taken before and after treatment. The subjects were divided into extraction (n = 113 patients, 2805 teeth) and non-extraction (n = 130 patients, 3616 teeth) groups and surgical (n = 56 patients, 1503 teeth) and non-surgical treatment (n = 187 patients, 4918 teeth) groups. These subjects were also divided into two or three groups based on the duration of multiloop edgewise archwire (MEAW) treatment, elastic use, and total treatment time: 0 month (T1; n = 184 patients, 4831 teeth), range 1-6 months (T2; n = 37 patients, 994 teeth), more than 6 months (T3; n = 22 patients, 596 teeth); range 0-6 months (n = 114 patients, 3016 teeth) more than 6 months (n = 129 patients, 3405 teeth); range 1-30 months (n = 148 patients, 3913 teeth) and more than 30 months (n = 95 patients, 2508 teeth). The prevalence of overall and severe root resorption evaluated by the number of subjects and teeth was compared with a chi-square test. A Student's t-test for unpaired data was used to determine any statistically significant differences. The prevalence of severe root resorption based on the number of teeth was significantly higher in the group with extractions (P root resorption (P root resorption was not significantly different between the subjects treated with or without surgery, but there was a significant increase when treatment time was prolonged (P root movement of the upper central incisors and the distance from their root apices to the cortical bone surface (P root resorption. These results indicate that orthodontic treatment with extractions, long-term use of a MEAW appliance and elastics, treatment

  9. Reirradiation for recurrent head and neck cancers using charged particle or photon radiotherapy.

    Science.gov (United States)

    Yamazaki, Hideya; Demizu, Yusuke; Okimoto, Tomoaki; Ogita, Mikio; Himei, Kengo; Nakamura, Satoaki; Suzuki, Gen; Yoshida, Ken; Kotsuma, Tadayuki; Yoshioka, Yasuo; Oh, Ryoongjin

    2017-07-01

    To examine the outcomes of reirradiation for recurrent head and neck cancers using different modalities. This retrospective study included 26 patients who received charged particle radiotherapy (CP) and 150 who received photon radiotherapy (117 CyberKnife radiotherapy [CK] and 36 intensity-modulated radiotherapy [IMRT]). Inverse probability of treatment weighting (IPTW) involving propensity scores was used to reduce background selection bias. Higher prescribed doses were used in CP than photon radiotherapy. The 1‑year overall survival (OS) rates were 67.9% for CP and 54.1% for photon radiotherapy (p = 0.15; 55% for CK and 51% for IMRT). In multivariate Cox regression, the significant prognostic factors for better survival were nasopharyngeal cancer, higher prescribed dose, and lower tumor volume. IPTW showed a statistically significant difference between CP and photon radiotherapy (p = 0.04). The local control rates for patients treated with CP and photon radiotherapy at 1 year were 66.9% (range 46.3-87.5%) and 67.1% (range 58.3-75.9%), respectively. A total of 48 patients (27%) experienced toxicity grade ≥3 (24% in the photon radiotherapy group and 46% in the CP group), including 17 patients with grade 5 toxicity. Multivariate analysis revealed that younger age and a larger planning target volume (PTV) were significant risk factors for grade 3 or worse toxicity. CP provided superior survival outcome compared to photon radiotherapy. Tumor volume, primary site (nasopharyngeal), and prescribed dose were identified as survival factors. Younger patients with a larger PTV experienced toxicity grade ≥3.

  10. Radiosurgery for metastatic disease at the craniocervical junction.

    Science.gov (United States)

    Tuchman, Alexander; Yu, Cheng; Chang, Eric L; Kim, Paul E; Rusch, Mairead C; Apuzzo, Michael L J

    2014-12-01

    Metastatic disease of the craniovertebral junction (CVJ) can cause pain, cranial nerve deficits, occipitocervical instability, or brainstem/spinal cord compression if left untreated. Many patients with metastasis in this region have a high burden of systemic disease and short life expectancy, making them poor candidates for aggressive surgical resections and fusion procedures. Traditionally, symptom palliation and local disease control in these patients has been achieved through conventional radiation therapy. Stereotactic radiosurgery (SRS) has the advantage of precisely delivering radiation to a target in fewer fractions. To our knowledge, we report the results of the largest series of patients with CVJ metastasis treated with stereotactic radiosurgery. We performed a retrospective review of 9 consecutive patients with 10 tumors of the CVJ treated with SRS at the Keck Medical Center of the University of Southern California. Two tumors were treated with Gamma Knife, whereas the other 8 received CyberKnife. The median marginal dose was 20 Gy (16-24 Gy) over 1-5 fractions. Point maximal dose to the brainstem or spinal cord ranged between 8 and 18.9 Gy. Median survival was 4 months (1-51 months). Five of six patients presenting with pain had at least partial symptom resolution. No patient went on to require surgical decompression or fusion, and there were no complications directly related to SRS. In well-selected patients, SRS for metastatic lesions of the CVJ has a low risk for complications or treatment failure, while achieving a high rate of palliation of pain symptoms. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Stereotactic body radiation therapy with or without transarterial chemoembolization for patients with primary hepatocellular carcinoma: preliminary analysis

    International Nuclear Information System (INIS)

    Choi, Byung Ock; Choi, Ihl Bohng; Jang, Hong Seok; Kang, Young Nam; Jang, Ji Sun; Bae, Si Hyun; Yoon, Seung Kew; Chai, Gyu Young; Kang, Ki Mun

    2008-01-01

    The objectives of this retrospective study was to evaluate the efficacy of stereotactic body radiation therapy (SBRT) for small non-resectable hepatocellular carcinoma (HCC) and SBRT combined with transarterial chemoembolization (TACE) for advanced HCC with portal vein tumor thrombosis (PVTT). Thirty one patients with HCC who were treated with SBRT were used for the study. We studied 32 HCC lesions, where 23 lesions (22 patients) were treated targeting small non-resectable primary HCC, and 9 lesions (9 patients) targeting PVTT using the Cyberknife. All the 9 patients targeting PVTT received TACE for the advanced HCC. Tumor volume was 3.6–57.3 cc (median, 25.2 cc) and SBRT dose was 30–39 Gy (median, 36 Gy) in 3 fractions for consecutive days for 70–85% of the planned target volume. The median follow up was 10.5 months. The overall response rate was 71.9% [small HCC: 82.6% (19/23), advanced HCC with PVTT: 44.4% (4/9)], with the complete and partial response rates of 31.3% [small HCC: 26.1% (6/23), advanced HCC with PVTT: 11.1% (1/9)], and 50.0% [small HCC: 56.5% (13/23), advanced HCC with PVTT: 33.3% (3/9)], respectively. The median survival period of small HCC and advanced HCC with PVTT patients was 12 months and 8 months, respectively. No patient experienced Grade 4 toxicity. SBRT for small HCC and SBRT combined with TACE for advanced HCC with PVTT showed feasible treatment modalities with minimal side effects in selected patients with primary HCC

  12. The complex treatment of acute pancreatitis using miniinvasive surgical treatment

    Directory of Open Access Journals (Sweden)

    G. I. Ohrimenko

    2015-06-01

    Full Text Available Nowadays methods used in acute pancreatitis diagnostic do not allow to find the most optimal indications, terms of surgical drainage approaches in surgical treatment of acute pancreatitis. Aim. In order to develop optimal diagnostic and treatment algorithm 316 patients took part in the study. Methods and results. Surgery outcomes were assessed by the next methods: ultrasound, computed tomography. We determined that destructive changes in pancreas in group of sterile pancreatic necrosis were limited. In cases of infected pancreatic necrosis the damage was spread and the disease course was septic. That’s why the operative treatment in cases of sterile pancreatitis has to be used with strict indications such as fermentative peritonitis, acute liquid formations, acute pseudocysts. Conclusion. In such cases miniinvasive surgery is mainly used while in the cases of infected pancreatic necrosis we ought to choose open surgery treatment.

  13. Validation of the Treatment Motivation Scales for forensic outpatient treatment (TMS-F)

    NARCIS (Netherlands)

    Drieschner, Klaus H.; Boomsma, Anne

    The validity of the Treatment Motivation Scales for outpatient offender treatment (TMS-F), a self-report questionnaire with scales for the motivation of patients to engage in the treatment and six cognitive and emotional determinants of this motivation, is evaluated in two studies. In Study 1 (N =

  14. Treatment Options for Retinoblastoma

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... or in other places in the body. Treatment Option Overview Key Points There are different types of ...

  15. Treatment of Functional Constipation

    Directory of Open Access Journals (Sweden)

    H Karami

    2014-04-01

    Full Text Available Childhood constipation is ofton a long_term problem requiring treatment over months or years. There is no single treatment metod for constipation and many children do not respond and continue to have chronic problems. Treatment is consisted of: Disimpaction,Drug adminstration , Diet modilation, and behaverial therapy. It is necessary in all cases that not responding to conventional therapy, un diagnosed organic causes, non proper drug, short course therapy, behaverial disorder and withholding should be considered. Internal anal achalasia, Neural tube defect, Neurointestinal dysplasia. and food allergy are the most important predisposing factors in treatment failer . PEG is drug of choice for treatment and therapy must be continued for several months or years. Psycologic consulting should be considered in patients with severe behaverial disorder.   Key words: Children, Functional Constipation, Treatment.

  16. Treatment of attention deficit hyperactivity disorder in children: Predictors of treatment outcome

    NARCIS (Netherlands)

    van der Oord, S.; Prins, P.J.M.; Oosterlaan, J.; Emmelkamp, P.M.G.

    2008-01-01

    Objective: The present study investigated the predictive power of anxiety, IQ, severity of ADHD and parental depression on the outcome of treatment in children with ADHD. Method: Fifty children with ADHD (ages 8-12) were randomized to a 10-week treatment of methylphenidate or to a treatment of

  17. Breast Cancer: Treatment Options

    Science.gov (United States)

    ... Breast Cancer > Breast Cancer: Treatment Options Request Permissions Breast Cancer: Treatment Options Approved by the Cancer.Net Editorial ... can be addressed as quickly as possible. Recurrent breast cancer If the cancer does return after treatment for ...

  18. Inventtional treatment of varicocele

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2016-09-15

    Varicocele is a dilatation of the veins in the pampiniform plexus and manifests as mass-effect, pain, testicular atrophy, or male infertility. Traditionally, surgical treatment has been the mainstay of treatment of varicocele, while interventional treatment, which is endovascular embolization of the testicular vein, has been gaining popularity recently. In this review, diagnosis of the disease, indications and procedure details of interventional treatment, results, and complications are discussed.

  19. Wastewater Treatment Plants

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — The actual treatment areas for municipal, industrial, and semi-public wastewater treatment facilities in Iowa for the National Pollutant Discharge Elimination System...

  20. Working during cancer treatment

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000834.htm Working during cancer treatment To use the sharing features on this page, ... JavaScript. Many people continue to work throughout their cancer treatment. Cancer, or the side effects of treatment, may ...

  1. NIAAA Alcohol Treatment Navigator

    Science.gov (United States)

    ... What to Know About Alcohol Treatment What Is Alcohol Use Disorder (AUD)? What Types of Alcohol Treatment Are Available? ... What to Know About Alcohol Treatment What is alcohol use disorder (AUD)? A health condition that can improve with ...

  2. Research Areas: Treatment

    Science.gov (United States)

    The development of more effective and less toxic treatments is fundamental to improving outcomes for patients with cancer. NCI is leading efforts on several fronts to develop and evaluate new cancer treatments.

  3. Lifetime treatment contact and delay in treatment seeking after first onset of a mental disorder

    NARCIS (Netherlands)

    ten Have, M.; de Graaf, R.; van Dorsselaer, S.; Beekman, A.T.F.

    2013-01-01

    Objective: This study examined lifetime treatment contact and delays in treatment seeking, including rates for receipt of helpful treatment, after the onset of specific mental disorders and evaluated factors that predicted treatment seeking and delays in treatment seeking. Methods: Data were from

  4. Equal treatment of shareholders

    Directory of Open Access Journals (Sweden)

    Arsić Zoran

    2014-01-01

    Full Text Available Equal treatment of shareholders is regulated in Art.269 of Company Act (2011 of Republic of Serbia. Equal treatment of shareholders means that all shareholders are to be treated equally under same circumstances. Obligation to treat all shareholders equally rests on all company bodies, predominantly general meeting. The standard whether an action violates the principle of equal treatment of all shareholders regarding the main rights of shareholders (such as voting right etc. is the nominal value of shares, or the equal treatment per person regarding ancillary rights (such as right to speak in shareholders' meeting etc.. Any action deviating from this standard is unlawful if the unequal treatment is not justified on the facts. If the principle of equal treatment is violated by general meeting resolution, such resolution may be annulled by the court.

  5. Atrial Fibrillation: Treatment

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Atrial Fibrillation Atrial Fibrillation: Treatment Past Issues / Winter 2015 Table of Contents Treatment for atrial fibrillation depends on how often you have symptoms, how ...

  6. Anaerobic treatment techniques

    International Nuclear Information System (INIS)

    Boehnke, B.; Bischofsberger, W.; Seyfried, C.F.

    1993-01-01

    This practical and theoretical guide presents the current state of knowledge in anaerobic treatment of industrial effluents with a high organic pollutant load and sewage sludges resulting from the treatment of municipal and industrial waste water. Starting from the microbiological bases of anaerobic degradation processes including a description and critical evaluation of executed plants, the book evolves the process-technical bases of anaerobic treatment techniques, derives relative applications, and discusses these with reference to excuted examples. (orig./UWA). 232 figs [de

  7. Cholesterol - drug treatment

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000314.htm Cholesterol - drug treatment To use the sharing features on ... treatment; Hardening of the arteries - statin Statins for Cholesterol Statins reduce your risk of heart disease, stroke, ...

  8. Intensive treatment models and coercion

    DEFF Research Database (Denmark)

    Ohlenschlaeger, Johan; Thorup, Anne; Petersen, Lone

    2007-01-01

    . Hospital-based Rehabilitation, an intensified inpatient treatment model, Integrated Treatment, an intensified model of Assertive Community Treatment, and standard treatment were compared for patients with first-episode schizophrenia-spectrum disorders. Ninety-four patients with first-episode schizophrenia......Little evidence exists concerning the optimal treatment for patients with first-episode schizophrenia-spectrum disorders and the effect on traditional outcomes. The aim was to investigate whether optimal treatment models have an effect on the level of use of coercion and on traditional outcomes......-spectrum disorders estimated to benefit from long-term hospitalization were included consecutively from the Copenhagen OPUS-trial and randomized to the three treatment models. At 1-year follow-up, Hospital-based Rehabilitation and Integrated Treatment had better scores on symptoms in the negative dimension...

  9. [Treatment and prevention of cancer treatment related oral mucositis].

    Science.gov (United States)

    Ruiz-Esquide, Gonzalo; Nervi, Bruno; Vargas, Alex; Maíz, Alberto

    2011-03-01

    One of the most common and troublesome complications of modern intensive anticancer treatments is oral mucositis. The purpose of this review is to summarize current evidence and clinical guidelines regarding its prevention and therapy. The use of keratinocyte growth factor-1, supplementary glutamine and other recently developed treatment modalities are discussed. The injury of the oral mucosa caused by antineoplastic agents promotes the local expression of multiple pro-inflammatory and pro-apoptotic molecules and eventually leads to the development of ulcers. Such lesions predispose patients to several infectious and nutritional complications. Also, they lead to modification of treatment schedules, potentially affecting overall prognosis. Local cryotherapy with ice chips and phototherapy with low energy laser may be useful as preventive measures. Mouthwashes with allopurinol and phototherapy with low energy laser can be used as treatment. In radiotherapy, special radiation administration techniques should be used to minimize mucosal injury. Pain control should always be optimized, with the use of patient controlled analgesia and topical use of morphine. Supplemental glutamine should not be used outside of research protocols. Lastly, thorough attention should be paid to general care and hygiene measures.

  10. Radiation treatment of benign diseases

    International Nuclear Information System (INIS)

    Reitan, J.B.; Flatby, J.; Backe, S.; Lundgren, L.

    1984-01-01

    The report deals with an estimation of the volume of radiation treatment of benign diseases in Norway and gives a survey of the subjective opinion of patients regarding the result of the treatment. Reported subjective recovery after radiation treatment seems to be at the same level as recovery without treatment. For an indication of the objective effect of radiation treatment of benign diseases, the subjective effect of this treatment has to be compared with objective findings

  11. Life After Breast Cancer Treatment

    Science.gov (United States)

    ... know what to expect after treatment ends. Emotional effects of treatment The last day of treatment It is normal to have different feelings, emotions and fears after treatment ends. Not everyone feels ...

  12. Does phasic trauma treatment make patients with dissociative identity disorder treatment more dissociative?

    Science.gov (United States)

    Brand, Bethany; Loewenstein, Richard J

    2014-01-01

    Proponents of the iatrogenic model of the etiology of dissociative identity disorder (DID) have expressed concern that treatment focused on direct engagement and interaction with dissociated self-states harms DID patients. However, empirical data have shown that this type of DID treatment is beneficial. Analyzing data from the prospective Treatment of Patients With Dissociative Disorders (TOP DD) Study, we test empirically whether DID treatment is associated with clinically adverse manifestations of dissociated self-states: acting so differently that one feels like different people, hearing voices, and dissociative amnesia. We show that, over the course of the study, there were significant decreases in feeling like different people and hearing voices. These results indicate that this form of DID treatment does not lead to symptomatic worsening in these dimensions, as predicted by the iatrogenic model. Indeed, treatment provided by TOP DD therapists reduced, rather than increased, the extent to which patients experienced manifestations of pathological dissociation. Because severe symptomatology and impairment are associated with DID, iatrogenic harm may come from depriving DID patients of treatment that targets DID symptomatology.

  13. Towards personalizing treatment for depression : developing treatment values markers.

    Science.gov (United States)

    Wittink, Marsha N; Morales, Knashawn H; Cary, Mark; Gallo, Joseph J; Bartels, Stephen J

    2013-01-01

    While 'personalized medicine' commonly refers to genetic markers or profiles associated with pharmacological treatment response, tailoring treatments to patient preferences and values is equally important. To describe and demonstrate a method to develop 'values markers,' or profiles based on the relative importance of attributes of depression treatment. Discrete choice analysis was used to assess individuals' relative preferences for features of depression treatment. Preference profiles were developed using latent profile analysis. Eighty-six adults participating in an internet-based discrete choice questionnaire. Participants were presented with two depression scenarios representing mild and severe depression. For each scenario, they were asked to compare 18 choice sets based on the type of medication side effect (nausea, dizziness, and sexual dysfunction) and severity (mild, moderate, and severe); and for counseling frequency (once per week or every other week) and provider setting (the office of a mental health professional, primary care doctor, or spiritual counselor). Three profiles were identified: profile 1 was associated with a preference for counseling and an avoidance of medication side effects; profile 2 with an avoidance of strong medication side effects and for receiving counseling in medical settings; and profile 3 with a preference for medication over counseling. When presented with a severe depression scenario, there was a higher prevalence for profile 1 and patients were more likely to prefer mental health over primary care and spiritual settings. Values markers may provide a foundation for personalized medicine, and reflect current initiatives emphasizing patient-centered care. Next steps should assess whether values markers are predictive of treatment initiation and adherence.

  14. Prostate cancer - treatment

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/patientinstructions/000403.htm Prostate cancer - treatment To use the sharing features on this page, ... drugs is recommended. References National Cancer Institute. Prostate cancer treatment (PDQ): Stages of prostate cancer. Updated July 31, ...

  15. Nasal Wash Treatment

    Science.gov (United States)

    ... Medications Alternative Therapies Nasal Wash Treatment Nasal Wash Treatment Make an Appointment Ask a Question Refer Patient The Centers for Disease Control (CDC) guidelines for preparing water used in a nasal wash are listed below. Many ...

  16. Stereotactic Robotic Body Radiotherapy for Patients With Unresectable Hepatic Oligorecurrence.

    Science.gov (United States)

    Berkovic, Patrick; Gulyban, Akos; Nguyen, Paul Viet; Dechambre, David; Martinive, Philippe; Jansen, Nicolas; Lakosi, Ferenc; Janvary, Levente; Coucke, Philippe A

    2017-12-01

    The purpose of this study was to analyze local control (LC), liver progression-free survival (PFS), and distant PFS (DFS), overall survival (OS), and toxicity in a cohort of patients treated with stereotactic body radiotherapy (SBRT) with fiducial tracking for oligorecurrent liver lesions; and to evaluate the potential influence of lesion size, systemic treatment, physical and biologically effective dose (BED), treatment calculation algorithms and other parameters on the obtained results. Unoperable patients with sufficient liver function had [18F]-fluorodeoxyglucose-positron emission tomography-computed tomography and liver magnetic resonance imaging to confirm the oligorecurrent nature of the disease and to further delineate the gross tumor volume (GTV). An intended dose of 45 Gy in 3 fractions was prescribed on the 80% isodose and adapted if risk-related. Treatment was executed with the CyberKnife system (Accuray Inc) platform using fiducials tracking. Initial plans were recalculated using the Monte Carlo algorithm. Patient and treatment data were processed using the Kaplan-Meier method and log rank test for survival analysis. Between 2010 and 2015, 42 patients (55 lesions) were irradiated. The mean GTV and planning target volume (PTV) were 30.5 cc and 96.8 cc, respectively. Treatments were delivered 3 times per week in a median of 3 fractions to a PTV median dose of 54.6 Gy. The mean GTV and PTV D98% were 51.6 Gy and 51.2 Gy, respectively. Heterogeneity corrections did not influence dose parameters. After a median follow-up of 18.9 months, the 1- and 2-year LC/liver PFS/DFS/OS were 81.3%/55%/62.4%/86.9%, and 76.3%/42.3%/52%/78.3%, respectively. Performance status and histology had a significant effect on LC, whereas age (older than 65 years) marginally influenced liver PFS. Clinical target volume physical dose V45 Gy > 95%, generalized equivalent uniform dose (a = -30) > 45 Gy and a BED (α/β = 10) V105 Gy > 96% showed statistically significant effect on

  17. Dosimetric effect of intrafraction tumor motion in phase gated lung stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Zhao Bo; Yang Yong; Li Tianfang; Li Xiang; Heron, Dwight E.; Huq, M. Saiful

    2012-01-01

    Purpose: A major concern for lung intensity modulated radiation therapy delivery is the deviation of actually delivered dose distribution from the planned one due to simultaneous movements of multileaf collimator (MLC) leaves and tumor. For gated lung stereotactic body radiotherapy treatment (SBRT), the situation becomes even more complicated because of SBRT's characteristics such as fewer fractions, smaller target volume, higher dose rate, and extended fractional treatment time. The purpose of this work is to investigate the dosimetric effect of intrafraction tumor motion during gated lung SBRT delivery by reconstructing the delivered dose distribution with real-time tumor motion considered. Methods: The tumor motion data were retrieved from six lung patients. Each of them received three fractions of stereotactic radiotherapy treatments with Cyberknife Synchrony (Accuray, Sunnyvale, CA). Phase gating through an external surrogate was simulated with a gating window of 5 mm. The resulting residual tumor motion curves during gating (beam-on) were retrieved. Planning target volume (PTV) was defined as physician-contoured clinical target volume (CTV) surrounded by an isotropic 5 mm margin. Each patient was prescribed with 60 Gy/3 fractions. The authors developed an algorithm to reconstruct the delivered dose with tumor motion. The DMLC segments, mainly leaf position and segment weighting factor, were recalculated according to the probability density function of tumor motion curve. The new DMLC sequence file was imported back to treatment planning system to reconstruct the dose distribution. Results: Half of the patients in the study group experienced PTV D95% deviation up to 26% for fractional dose and 14% for total dose. CTV mean dose dropped by 1% with tumor motion. Although CTV is almost covered by prescribed dose with 5 mm margin, qualitative comparison on the dose distributions reveals that CTV is on the verge of underdose. The discrepancy happens due to tumor

  18. Modeling Vertical Flow Treatment Wetland Hydraulics to Optimize Treatment Efficiency

    Science.gov (United States)

    2011-03-24

    be forced to flow in a 90 serpentine manner back and forth as it moves upward through the wetland (think waiting in line at Disneyland ). This...Flow Treatment Wetland Hydraulics to Optimize Treatment Efficiency 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR

  19. Extracorporeal Treatment for Lithium Poisoning

    DEFF Research Database (Denmark)

    Decker, Brian S; Goldfarb, David S; Dargan, Paul I

    2015-01-01

    The Extracorporeal Treatments in Poisoning Workgroup was created to provide evidence-based recommendations on the use of extracorporeal treatments in poisoning. Here, the EXTRIP workgroup presents its recommendations for lithium poisoning. After a systematic literature search, clinical and toxico......The Extracorporeal Treatments in Poisoning Workgroup was created to provide evidence-based recommendations on the use of extracorporeal treatments in poisoning. Here, the EXTRIP workgroup presents its recommendations for lithium poisoning. After a systematic literature search, clinical...... extraction of patient-level data. The workgroup concluded that lithium is dialyzable (Level of evidence=A) and made the following recommendations: Extracorporeal treatment is recommended in severe lithium poisoning (1D). Extracorporeal treatment is recommended if kidney function is impaired and the [Li...... treatment (1D), but continuous RRT is an acceptable alternative (1D). The workgroup supported the use of extracorporeal treatment in severe lithium poisoning. Clinical decisions on when to use extracorporeal treatment should take into account the [Li(+)], kidney function, pattern of lithium toxicity...

  20. Treatment of bipolar disorder: a complex treatment for a multi-faceted disorder

    Directory of Open Access Journals (Sweden)

    Fresno David

    2007-10-01

    Full Text Available Abstract Background Manic-depression or bipolar disorder (BD is a multi-faceted illness with an inevitably complex treatment. Methods This article summarizes the current status of our knowledge and practice of its treatment. Results It is widely accepted that lithium is moderately useful during all phases of bipolar illness and it might possess a specific effectiveness on suicidal prevention. Both first and second generation antipsychotics are widely used and the FDA has approved olanzapine, risperidone, quetiapine, ziprasidone and aripiprazole for the treatment of acute mania. These could also be useful in the treatment of bipolar depression, but only limited data exists so far to support the use of quetiapine monotherapy or the olanzapine-fluoxetine combination. Some, but not all, anticonvulsants possess a broad spectrum of effectiveness, including mixed dysphoric and rapid-cycling forms. Lamotrigine may be effective in the treatment of depression but not mania. Antidepressant use is controversial. Guidelines suggest their cautious use in combination with an antimanic agent, because they are supposed to induce switching to mania or hypomania, mixed episodes and rapid cycling. Conclusion The first-line psychosocial intervention in BD is psychoeducation, followed by cognitive-behavioral therapy. Other treatment options include Electroconvulsive therapy and transcranial magnetic stimulation. There is a gap between the evidence base, which comes mostly from monotherapy trials, and clinical practice, where complex treatment regimens are the rule.

  1. Bell's Palsy Treatment

    Science.gov (United States)

    ... Stories Español Eye Health / Eye Health A-Z Bell's Palsy Sections What Is Bell's Palsy? Bell's Palsy Symptoms Bell's Palsy Treatment Bell's Palsy Treatment Leer en Español: Tratamiento de la parálisis ...

  2. Treatment Option Overview (Ewing Sarcoma)

    Science.gov (United States)

    ... Ewing Sarcoma Treatment Osteosarcoma Treatment Research Ewing Sarcoma Treatment (PDQ®)–Patient Version General Information About Ewing Sarcoma ... started or in another part of the body. Treatment Option Overview Key Points There are different types ...

  3. Treatment

    Directory of Open Access Journals (Sweden)

    Safaa M. Raghab

    2013-08-01

    The main goal of this study is to utilize a natural low cost material “as an accelerator additive to enhance the chemical treatment process using Alum coagulant and the accelerator substances were Perlite and Bentonite. The performance of the chemical treatment was enhanced using the accelerator substances with 90 mg/l Alum as a constant dose. Perlite gave better performance than the Bentonite effluent. The removal ratio for conductivity, turbidity, BOD and COD for Perlite was 86.7%, 87.4%, 89.9% and 92.8% respectively, and for Bentonite was 83.5%, 85.0%, 86.5% and 85.0% respectively at the same concentration of 40 mg/l for each.

  4. Improved process for the treatment of bituminous materials. [two heat treatments

    Energy Technology Data Exchange (ETDEWEB)

    1947-04-30

    A continuous process for recovering valuable hydrocarbon oils from solid minerals adapted to produce such oils upon application of heat, consists of reducing the raw minerals to a powder, suspending the powdered minerals in a gaseous medium and subjecting the suspension thus formed to heat treatment in a primary reaction zone, followed by heat treatment in a secondary reaction zone separate from the primary reaction zone. The temperature during the second of said treatments being substantially higher than that of the first.

  5. Treatment of Gas

    Science.gov (United States)

    ... Funding IFFGD Symposium reports Industry Council Contact Us Treatment of Gas You are here: Home Symptoms & Causes Intestinal Gas ... Controlling Intestinal Gas Foods That May Cause Gas Treatment of Gas Tips on Controlling Gas Adapted from IFFGD Publication # ...

  6. Patient-Treatment Matching Improves Compliance of Alcoholics in Outpatient Treatment

    DEFF Research Database (Denmark)

    Nielsen, Anette Søgaard; Nielsen, Bent; Wraae, Olaf

    1998-01-01

    curves. The consequence of compliance for long-term prognosis was described by means of the Addiction Severity Index. The form of treatment in itself had no importance for compliance. However, correct matching of a patient and a treatment structure resulted in a compliance rate of 63% as opposed to 38...

  7. Integrated nonthermal treatment system study

    International Nuclear Information System (INIS)

    Biagi, C.; Bahar, D.; Teheranian, B.; Vetromile, J.; Quapp, W.J.; Bechtold, T.; Brown, B.; Schwinkendorf, W.; Swartz, G.

    1997-01-01

    This report presents the results of a study of nonthermal treatment technologies. The study consisted of a systematic assessment of five nonthermal treatment alternatives. The treatment alternatives consist of widely varying technologies for safely destroying the hazardous organic components, reducing the volume, and preparing for final disposal of the contact-handled mixed low-level waste (MLLW) currently stored in the US Department of Energy complex. The alternatives considered were innovative nonthermal treatments for organic liquids and sludges, process residue, soil and debris. Vacuum desorption or various washing approaches are considered for treatment of soil, residue and debris. Organic destruction methods include mediated electrochemical oxidation, catalytic wet oxidation, and acid digestion. Other methods studied included stabilization technologies and mercury separation of treatment residues. This study is a companion to the integrated thermal treatment study which examined 19 alternatives for thermal treatment of MLLW waste. The quantities and physical and chemical compositions of the input waste are based on the inventory database developed by the US Department of Energy. The Integrated Nonthermal Treatment Systems (INTS) systems were evaluated using the same waste input (2,927 pounds per hour) as the Integrated Thermal Treatment Systems (ITTS). 48 refs., 68 figs., 37 tabs

  8. Integrated nonthermal treatment system study

    Energy Technology Data Exchange (ETDEWEB)

    Biagi, C.; Bahar, D.; Teheranian, B.; Vetromile, J. [Morrison Knudsen Corp. (United States); Quapp, W.J. [Nuclear Metals (United States); Bechtold, T.; Brown, B.; Schwinkendorf, W. [Lockheed Martin Idaho Technologies Co., Idaho Falls, ID (United States); Swartz, G. [Swartz and Associates (United States)

    1997-01-01

    This report presents the results of a study of nonthermal treatment technologies. The study consisted of a systematic assessment of five nonthermal treatment alternatives. The treatment alternatives consist of widely varying technologies for safely destroying the hazardous organic components, reducing the volume, and preparing for final disposal of the contact-handled mixed low-level waste (MLLW) currently stored in the US Department of Energy complex. The alternatives considered were innovative nonthermal treatments for organic liquids and sludges, process residue, soil and debris. Vacuum desorption or various washing approaches are considered for treatment of soil, residue and debris. Organic destruction methods include mediated electrochemical oxidation, catalytic wet oxidation, and acid digestion. Other methods studied included stabilization technologies and mercury separation of treatment residues. This study is a companion to the integrated thermal treatment study which examined 19 alternatives for thermal treatment of MLLW waste. The quantities and physical and chemical compositions of the input waste are based on the inventory database developed by the US Department of Energy. The Integrated Nonthermal Treatment Systems (INTS) systems were evaluated using the same waste input (2,927 pounds per hour) as the Integrated Thermal Treatment Systems (ITTS). 48 refs., 68 figs., 37 tabs.

  9. Getting Treatment for ADHD

    Medline Plus

    Full Text Available ... Finder Getting Treatment Without treatment, a child with ADHD may fall behind in school and continue having trouble with friendships. Family life ... speak. Contents What is ADHD? How Common is ADHD? Common Signs and Symptoms Getting Treatment Supporting School Success The Teenage Years Working ... Connect ...

  10. Getting Treatment for ADHD

    Medline Plus

    Full Text Available ... is that effective treatment is available . With the right medical treatment, children with ADHD can improve their ability to pay attention and control their behavior. The right care can help them grow, learn, and ... and help the child function at a normal level. Treatment may include ...

  11. Waste Water Treatment Unit

    International Nuclear Information System (INIS)

    Ramadan, A.E.K.

    2004-01-01

    A wastewater treatment plant to treat both the sanitary and industrial effluent originated from process, utilities and off site units of the refinery is described. The purpose is to obtain at the end of the treatment plant, a water quality that is in compliance with contractual requirements and relevant environmental regulations. first treatment (pretreatment). Primary de-oiling, Equalization, Neutralization, Secondary de-oiling. Second treatment (Biological), The mechanism of BOD removal, Biological flocculation, Nutrient requirements, Nitrification, De-nitrification, Effect of temperature, Effect of ph, Toxicity

  12. [Psychiatric treatment sentences.

    DEFF Research Database (Denmark)

    Stevens, Hanne; Nordentoft, Merete; Agerbo, Esben

    2010-01-01

    INTRODUCTION: Previous Danish studies of the increasing number of sentences to psychiatric treatment (SPT) have compared prevalent populations of persons undergoing treatment with incident measures of reported crimes. Examining the period 1990-2006, we studied incident sentences, taking the type...

  13. Treatment versus proportionality

    DEFF Research Database (Denmark)

    Sorensen, David Woodrow Mattson

    2010-01-01

    Persons suffering from mental illness, retardation or other disturbances who commit crimes in Denmark cannot be punished, but are instead sentenced to treatment. In the past, these sentences were always indeterminate, meaning that treatment regimens were only terminated when psychiatrists judged ...

  14. Hazardous waste treatment facility and skid-mounted treatment systems at Los Alamos

    International Nuclear Information System (INIS)

    Lussiez, G.W.; Zygmunt, S.J.

    1993-01-01

    To centralize treatment, storage, and staging areas for hazardous wastes, Los Alamos National Laboratory has designed a 12,000-ft 2 hazardous waste treatment facility. The facility will house a treatment room for each of four kinds of wastes: nonradioactive characteristic wastes, nonradioactive listed wastes radioactive characteristic wastes, and radioactive listed wastes. The facility will be used for repacking labpacks, bulking small organic waste volumes, processing scintillation vials, treating reactives such as lithium hydride and pyrophoric uranium, treating contaminated solids such as barium sand, and treating plating wastes. The treated wastes will then be appropriately disposed of. This report describes the integral features of the hazardous waste treatment facility

  15. Risk profiles of treatment noncompletion for inpatients and outpatients undergoing alcohol disorder rehabilitation treatment

    Directory of Open Access Journals (Sweden)

    Preuss UW

    2012-05-01

    Full Text Available Ulrich W Preuss,1 Jörg Zimmermann,2,3 Gabriele Schultz,2 Anna Watzke,2 Peggy Schmidt,4 Bärbel Löhnert,5 Michael Soyka2,61Department of Psychiatry, Psychotherapy and Psychosomatics, University of Halle-Wittenberg, Halle, Germany; 2Ev Krankenhaus Bethanien GmbH, Fachklinik Gristower Wiek, Johanna-Odebrecht-Stiftung, Germany; 3Karl-Jaspers-Klinik, Fachkrankenhaus für Psychiatrie und Psychotherapie, Psychiatrieverbund Oldenburger Land, Germany; 4Department of Psychiatry, Ludwig-Maximilians-Universität Munich, Germany; 5Klientenzentrierte Problemberatung, Dachau/Munich, Germany; 6Privatklinik Meiringen, Meiringen, Switzerland Background: Rehabilitation treatment noncompletion is considered a risk factor for long term relapse in alcohol-dependent individuals. The aim of this analysis of in- and outpatients in alcohol dependence rehabilitation in Germany is to identify social, mental, and somatic risk profiles for treatment noncompletion.Methods: A total of 92 individuals from an outpatient program and 303 individuals from two inpatient rehabilitation treatment units in three different locations in Germany were recruited and assessed with a structured interview and several measures of psychopathology (personality disorders, anxiety, depression, and impulsivity at treatment admission, with termination at 12 months follow-up. Participants were subdivided into treatment completers and noncompleters for any reason.Results: A total of 10.2% of inpatients and 16.1% of outpatients did not complete treatment. Compared with treatment completers, noncompleters had a significantly lower rate of continuous abstinence at 1-year follow-up, more recent alcohol consumption before admission, and a higher rate of borderline personality disorders. Among inpatients, an elevated rate of lifetime mental disorders, depression, and suicide attempts was found among treatment noncompleters; among outpatients, treatment noncompleters were more often than completers to be

  16. Report of AAPM TG 135: quality assurance for robotic radiosurgery.

    Science.gov (United States)

    Dieterich, Sonja; Cavedon, Carlo; Chuang, Cynthia F; Cohen, Alan B; Garrett, Jeffrey A; Lee, Charles L; Lowenstein, Jessica R; d'Souza, Maximian F; Taylor, David D; Wu, Xiaodong; Yu, Cheng

    2011-06-01

    The task group (TG) for quality assurance for robotic radiosurgery was formed by the American Association of Physicists in Medicine's Science Council under the direction of the Radiation Therapy Committee and the Quality Assurance (QA) Subcommittee. The task group (TG-135) had three main charges: (1) To make recommendations on a code of practice for Robotic Radiosurgery QA; (2) To make recommendations on quality assurance and dosimetric verification techniques, especially in regard to real-time respiratory motion tracking software; (3) To make recommendations on issues which require further research and development. This report provides a general functional overview of the only clinically implemented robotic radiosurgery device, the CyberKnife. This report includes sections on device components and their individual component QA recommendations, followed by a section on the QA requirements for integrated systems. Examples of checklists for daily, monthly, annual, and upgrade QA are given as guidance for medical physicists. Areas in which QA procedures are still under development are discussed.

  17. Constraints to organs at risks: a simple tool to uniform and secure the prescriptions and the realisation of dosimetry in a radiotherapy department; Contraintes aux organes a risque: un outil simple pour uniformiser et securiser les prescriptions et la realisation des dosimetries au sein d'un departement de radiotherapie

    Energy Technology Data Exchange (ETDEWEB)

    Mirabel, X.; Horn, S.; Le Tinier, F.; Attar, M.; Dewas, S.; Lacornerie, T.; Nickers, P.; Sarrazin, T.; Lartigau, E. [Centre Oscar-Lambret, 59 - Lille (France)

    2009-10-15

    The generalisation of the three dimensional conformal radiotherapy, then the conformal radiotherapy with intensity modulation, the receipt of a dosimetry scanner, two tomo-therapy devices and a cyberknife modified deeply our practices. The delineation of every organ at risk and the prescription of constraints to organs at risk became systematic. The new technologies by their possibilities in term of accuracy, conformity and tracking lead us to choose new therapy indications in situations where the control of dose to organs at risk is particularly crucial (hypo fractionated intra and extra cranial stereotaxic). This context make us feel the necessity to use a data base of constraints to organs at risk, for the classic fractionation and the hypo fractionation. An array containing all the data has been published as posters, it is displayed in large format in the work area for doctors in the area of simulation and data acquisition as well as dosimetry. (N.C.)

  18. Constraints to organs at risks: a simple tool to uniform and secure the prescriptions and the realisation of dosimetry in a radiotherapy department

    International Nuclear Information System (INIS)

    Mirabel, X.; Horn, S.; Le Tinier, F.; Attar, M.; Dewas, S.; Lacornerie, T.; Nickers, P.; Sarrazin, T.; Lartigau, E.

    2009-01-01

    The generalisation of the three dimensional conformal radiotherapy, then the conformal radiotherapy with intensity modulation, the receipt of a dosimetry scanner, two tomo-therapy devices and a cyberknife modified deeply our practices. The delineation of every organ at risk and the prescription of constraints to organs at risk became systematic. The new technologies by their possibilities in term of accuracy, conformity and tracking lead us to choose new therapy indications in situations where the control of dose to organs at risk is particularly crucial (hypo fractionated intra and extra cranial stereotaxic). This context make us feel the necessity to use a data base of constraints to organs at risk, for the classic fractionation and the hypo fractionation. An array containing all the data has been published as posters, it is displayed in large format in the work area for doctors in the area of simulation and data acquisition as well as dosimetry. (N.C.)

  19. Treatment of malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Yusa, Toshikazu

    2007-01-01

    In Japan, it is predicted that mesothelioma will rapidly increase in the future. Malignant pleural mesothelioma that accounts for approximately 90% of mesothelioma as a whole has a median survival time of approximately nine months which is considered a poor prognosis. As for the treatment of this disease, extrapleural pneumonectomy or pleurectomy/decortication are available for those patients who can be surgically operated on. However, since a complete cure rate is low when only surgical treatment is performed, generally a multimodality treatment is performed wherein chemotherapy and/or radiotherapy are combined. For chemotherapy, a large-scale randomized phase III study demonstrated that a treatment using two agents: pemetrexed, which is a new multitargeted antifolate, and cisplatin is effective. Pemetrexed will be the drug of first choice for mesothelioma in the future. As other treatment methods, chemohyperthermia, treatments using various kinds of cytokines and angiogenesis inhibitors, genetic treatment and photodynamic therapy have been attempted. The current treatment results for this disease are very poor, and there has been a strong demand for establishing an effective treatment method. (author)

  20. Diagnosis and treatment of haemorrhoids

    DEFF Research Database (Denmark)

    Buntzen, Steen; Christensen, Peter Quist; Khalid, Ali

    2013-01-01

    These guidelines provide a review of diagnosis, conservative and surgical treatment of haemorrhoids with primary focus on the surgical treatment. In symptomatic hemorrhoids it is recommended, that conservative treatment is used as basic treatment regardless of grading. The vast majority of grade II...

  1. Presolidification treatment of decontamination wastes

    International Nuclear Information System (INIS)

    Habayeb, M.A.

    1982-02-01

    Unsatisfactory leaching performance of several solidified decontamination solutions indicated a need for presolidification treatments to reduce the water sensitivity of the active chemicals. Chemical treatments examined in this work include pH adjustment, precipitation and oxidation-reduction reactions. The reactions involved in these treatments are discussed. The most suitable presolidification treatment for each decontamination solution has been identified. Further research is needed to test the effectivenss of these treatments

  2. Assessing self-determined motivation for addiction treatment: validity of the Treatment Entry Questionnaire.

    Science.gov (United States)

    Urbanoski, Karen A; Wild, T Cameron

    2012-07-01

    Although legal, formal, and informal social controls are frequently used to pressure individuals to enter treatment, motivational consequences of using these tactics have been neglected. Self-determination theory (SDT) provides a useful perspective for understanding client experiences of social controls and highlights the importance of self-determined motivation for long-term behavior change. This study assessed the construct validity of the Treatment Entry Questionnaire (TEQ), a brief scale derived from SDT to measure identified, introjected, and external treatment motivation. Two independent samples of clients entering Canadian residential and outpatient treatment completed TEQ items (ns = 529 and 623). Exploratory and confirmatory factor analyses supported a 9-item version of the scale, with 3 factors aligning with SDT motivational subtypes. Subscales showed high internal consistency and correlated as expected with social controls and perceived coercion at treatment entry. The TEQ-9 is a valid option for assessing self-determined motivation in clinical practice and evaluating coerced addiction treatment. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. PRE-FEASIBILITY STUDY FOR TREATMENT WETLAND APPLICATION FOR WASTEWATER TREATMENT IN DISPERSED DEVELOPMENT

    Directory of Open Access Journals (Sweden)

    Magdalena Gajewska

    2016-07-01

    Full Text Available The aim of the paper is to present the conducted analyses of pre-feasibility study of different approaches for wastewater management in a settlement of 180 persons. In the assessment both technical and economic aspects were analyzed. The costs were calculated for three different and, at the same time, most popular as well as possible technical solutions like: (i construction of local wastewater treatment plant with gravitational and pressurized networks, (ii construction of single family wastewater treatment plants, (iii construction of sealed septic tanks. Carried out analyses of investment and maintenance costs revealed that at the stage of construction the most expensive is local sewer network with treatment plant, while the construction of a single family treatment plant has similar cost regardless of the technology used. When the long term operation and investment cost are accounted the most economical reasonable solution is the application of wetland treatment for household wastewater treatment.

  4. Cradle Cap: Treatment

    Science.gov (United States)

    Cradle cap Treatment Cradle cap usually doesn't require medical treatment. It clears up on its own within a few months. In the meantime, wash ... tips can help you control and manage cradle cap. Gently rub your baby's scalp with your fingers ...

  5. Nonpharmacological treatment of epilepsy

    Directory of Open Access Journals (Sweden)

    V S Saxena

    2011-01-01

    Full Text Available Nonpharmacological treatment of epilepsy includes surgery, vagal nerve stimulation, ketogenic diet, and other alternative/complementary therapies, e.g., yoga, Ayurveda, electroencephalography (EEG biofeedback technique, aerobic exercise, music therapy, transcranial magnetic stimulation, acupuncture, and herbal remedies (traditional Chinese medicine. Alternative therapies, despite the term, should not be considered as an alternative to antiepileptic medication; they complement accepted drug treatment. Alternative therapies like yoga, through techniques that relax the body and mind, reduce stress, improve seizure control, and also improve quality of life. Ketogenic diet is a safe and effective treatment for intractable epilepsies; it has been recommended since 1921. The diet induces ketosis, which may control seizures. The most successful treatment of epilepsy is with modern antiepileptic drugs, which can achieve control of seizures in 70-80% cases. Patients opt for alternative therapies because they may be dissatisfied with antiepileptic drugs due to their unpleasant side effects, the long duration of treatment, failure to achieve control of seizures, cultural beliefs and, in the case of women, because they wish to get pregnant Surgical treatment may lead to physical and psychological sequelae and is an option only for a minority of patients. This article presents supportive evidence from randomized controlled trials done to assess the benefit of non-pharmacological treatment.

  6. Oral health: orthodontic treatment.

    Science.gov (United States)

    Martonffy, Andrea Ildiko

    2015-01-01

    Improper tooth alignment due to crowding, malocclusion, and missing teeth can cause difficulties with eating and speech, and premature wear. It is estimated that more than 20% of children would benefit from orthodontic treatment to correct these conditions, many of which will persist into adulthood if not corrected. Orthodontic care is gaining popularity among adults for similar concerns, as well as for correction of cosmetic issues. The psychological effects of malocclusion should not be ignored. The American Association of Orthodontists recommends that all children undergo evaluation at the first recognition of an orthodontic condition and no later than age 7 years. Some children will need early treatment to help eliminate developing conditions and improve the foundations of the bite, which can ease later treatment in adolescence. For others, treatment in adolescence without early treatment is recommended. Standard cemented braces or clear, removable aligners may be used, depending on the patient's corrective needs. Average treatment time is approximately 2 years; this may be shortened by the use of accelerative techniques. Routine preventive dental care should be continued during the treatment period. Written permission from the American Academy of Family Physicians is required for reproduction of this material in whole or in part in any form or medium.

  7. Treatment strategies for transuranic wastes

    International Nuclear Information System (INIS)

    Schneider, K.J.; Swanson, J.L.; Ross, W.A.; Allen, R.P.; Yasutake, K.M.

    1986-01-01

    This paper presents an analysis of treatment options or strategies for transuranic wastes expected to be generated at a commercial nuclear fuel reprocessing plant. Six potential options were analyzed, ranging from no treatment to maximum volume reduction and high quality waste forms. Economics for the total management of these (treatment, transportation, disposal) indicate life-cycle savings for extensive treatment are as high as $1.7 billion for 70,000 MTU. Evaluations of the waste processing and waste forms support the selection of a number of the extensive waste treatments. It is concluded that there are significant incentives for extensive treatment of transuranic wastes

  8. 75 FR 4227 - Phytosanitary Treatments; Location of and Process for Updating Treatment Schedules

    Science.gov (United States)

    2010-01-26

    ... phases of water and, as used in treatments, are thus a mixture of air and water. As the regulations... in how the terms ``approve,'' ``authorize,'' and ``certify'' are used in the existing treatment... term monitor, a term used in the general treatment requirements. The commenter stated that readers...

  9. Optical treatment of amblyopia in astigmatic children: the sensitive period for successful treatment.

    Science.gov (United States)

    Harvey, Erin M; Dobson, Velma; Clifford-Donaldson, Candice E; Miller, Joseph M

    2007-12-01

    To compare the effectiveness of eyeglass treatment of astigmatism-related amblyopia in children younger than 8 years (range, 4.75-7.99 years) versus children 8 years of age and older (range, 8.00-13.53 years) over short (6-week) and long (1-year) treatment intervals. Prospective, interventional, comparative case-control study. Four hundred forty-six nonastigmatic (right and left eye, or =1.00 D) Native American (Tohono O'odham) children in kindergarten or grades 1 through 6. Eyeglass correction of refractive error, prescribed for full-time wear, in astigmatic children. Amount of change in mean right-eye best-corrected letter visual acuity for treated astigmatic children versus untreated, age-matched nonastigmatic children after short (6-week) and long (1-year) treatment intervals. Astigmatic children had significantly reduced mean best-corrected visual acuity at baseline compared to nonastigmatic children. Astigmats showed significantly greater improvement in mean best-corrected visual acuity (0.08 logarithm of the minimum angle of resolution [logMAR] unit; approximately 1 line), than the nonastigmatic children (0.01 logMAR unit) over the 6-week treatment interval. No additional treatment effect was observed between 6 weeks and 1 year. Treatment effectiveness was not dependent on age group ( or =8 years) and was not influenced by previous eyeglass treatment. Despite significant improvement, mean best-corrected visual acuity in astigmatic children remained significantly poorer than in nonastigmatic children after 1 year of eyeglass treatment, even when analyses were limited to results from highly compliant children. Sustained eyeglass correction results in significant improvement in best-corrected visual acuity in astigmatic children, including those previously believed to be beyond the sensitive period for successful treatment.

  10. Interferon Treatment of Multiple Sclerosis

    OpenAIRE

    Alajbegovic, Azra; Deljo, Dervis; Alajbegovic, Salem; Djelilovic-Vranic, Jasminka; Todorovic, Ljubica; Tiric-Campara, Merita

    2012-01-01

    Introduction: In the treatment of Multiple Sclerosis (MS) differ: treatment of relapse, treatment slow the progression of the disease (immunomodulators and immunosuppression), and symptomatic treatment. The aim: The aim of this study is to analyze the application of interferon therapy in the treatment of MS-E: Process the disease, patients with multiple sclerosis who have passed the commission for multiple sclerosis at the Neurology Clinic of Clinical Center of Sarajevo University as a refere...

  11. [Strongyloidosis. Part IX. Treatment].

    Science.gov (United States)

    Soroczan, Wiesław

    2002-01-01

    The treatment of chronic and massive (uncomplicated) and severe (complicated) disseminated strongyloidosis, was presented from the historical point of view. The sequence of achievements in regard of treatment of the gentian violet, dithiazine iodide, benzimidazoles (thiabendazole, mebendazole, albendazole, cambendazole), ivermectin and cyclosporin A, was described. The recommendations for treatment of strongyloidosis are also given.

  12. Treatment planning: A key milestone to prevent treatment dropout in adolescents with borderline personality disorder.

    Science.gov (United States)

    Desrosiers, Lyne; Saint-Jean, Micheline; Breton, Jean-Jacques

    2015-06-01

    The aim of this study was to gain a broader appreciation of processes involved in treatment dropout in adolescents with borderline personality disorder (BPD). A constructivist grounded theory was chosen using a multiple-case research design with three embedded levels of analysis (adolescent, parent, and care setting). Theoretical sampling and the different stages of analysis specific to grounded theory were performed according to the iterative process of constant comparative analysis. Twelve cases were examined (nine dropouts among adolescents with BPD and for the purpose of falsification, one dropout of suicidal adolescent without BPD and two completed treatments among adolescents with BPD). To document the cases, three groups of informants were recruited (adolescents, parents, and therapists involved in the treatment) and 34 interviews were conducted. Psychological characteristics, perception of mental illness and mental health care, and help-seeking context were the specific treatment dropout vulnerabilities identified in adolescents with BPD and in their parents. However, their disengagement became an issue only when care-setting response--including mitigation of accessibility problems, adaptation of services to needs of adolescents with BPD, preparation for treatment, and concern for clinicians' disposition to treat--was ill-suited to these treatment dropout vulnerabilities. Treatment planning proves to be a key milestone to properly engage adolescents with BPD and their parent. Systematic assessment of treatment dropout vulnerabilities before the intervention plan is laid out could foster better-suited responses of the care setting thus decreasing the incidence of treatment discontinuation in adolescents with BPD. Treatment dropout vulnerabilities specific to adolescents with BPD and their parents can be detected before the beginning of treatment. Premature treatment termination may be prevented if the care setting considers these vulnerabilities at treatment

  13. Cost-Effective Fuel Treatment Planning

    Science.gov (United States)

    Kreitler, J.; Thompson, M.; Vaillant, N.

    2014-12-01

    The cost of fighting large wildland fires in the western United States has grown dramatically over the past decade. This trend will likely continue with growth of the WUI into fire prone ecosystems, dangerous fuel conditions from decades of fire suppression, and a potentially increasing effect from prolonged drought and climate change. Fuel treatments are often considered the primary pre-fire mechanism to reduce the exposure of values at risk to wildland fire, and a growing suite of fire models and tools are employed to prioritize where treatments could mitigate wildland fire damages. Assessments using the likelihood and consequence of fire are critical because funds are insufficient to reduce risk on all lands needing treatment, therefore prioritization is required to maximize the effectiveness of fuel treatment budgets. Cost-effectiveness, doing the most good per dollar, would seem to be an important fuel treatment metric, yet studies or plans that prioritize fuel treatments using costs or cost-effectiveness measures are absent from the literature. Therefore, to explore the effect of using costs in fuel treatment planning we test four prioritization algorithms designed to reduce risk in a case study examining fuel treatments on the Sisters Ranger District of central Oregon. For benefits we model sediment retention and standing biomass, and measure the effectiveness of each algorithm by comparing the differences among treatment and no treat alternative scenarios. Our objective is to maximize the averted loss of net benefits subject to a representative fuel treatment budget. We model costs across the study landscape using the My Fuel Treatment Planner software, tree list data, local mill prices, and GIS-measured site characteristics. We use fire simulations to generate burn probabilities, and estimate fire intensity as conditional flame length at each pixel. Two prioritization algorithms target treatments based on cost-effectiveness and show improvements over those

  14. Treatment Cost Analysis Tool (TCAT) for estimating costs of outpatient treatment services.

    Science.gov (United States)

    Flynn, Patrick M; Broome, Kirk M; Beaston-Blaakman, Aaron; Knight, Danica K; Horgan, Constance M; Shepard, Donald S

    2009-02-01

    A Microsoft Excel-based workbook designed for research analysts to use in a national study was retooled for treatment program directors and financial officers to allocate, analyze, and estimate outpatient treatment costs in the U.S. This instrument can also be used as a planning and management tool to optimize resources and forecast the impact of future changes in staffing, client flow, program design, and other resources. The Treatment Cost Analysis Tool (TCAT) automatically provides feedback and generates summaries and charts using comparative data from a national sample of non-methadone outpatient providers. TCAT is being used by program staff to capture and allocate both economic and accounting costs, and outpatient service costs are reported for a sample of 70 programs. Costs for an episode of treatment in regular, intensive, and mixed types of outpatient treatment were $882, $1310, and $1381 respectively (based on 20% trimmed means and 2006 dollars). An hour of counseling cost $64 in regular, $85 intensive, and $86 mixed. Group counseling hourly costs per client were $8, $11, and $10 respectively for regular, intensive, and mixed. Future directions include use of a web-based interview version, much like some of the commercially available tax preparation software tools, and extensions for use in other modalities of treatment.

  15. Duration of orthognathic-surgical treatment.

    Science.gov (United States)

    Paunonen, Jaakko; Helminen, Mika; Peltomäki, Timo

    2017-07-01

    The objective of this study was to determine the duration of orthognathic-surgical treatment conducted with conventional pre- and post-surgical orthodontic treatment phases. The study material was comprised of the files of 185 consecutive patients treated in Oral and Maxillofacial Unit, Tampere University Hospital, Finland, in 2007-2014. The files were reviewed and the following data was obtained: gender and age of patients, ICD-10 diagnosis, type of malocclusion, duration of pre- and post-surgical orthodontic treatment and type of operation. Total treatment duration (median) from placement of separating rings for banding until fixed orthodontic appliances were removed and retention period started was 31.1 months, of which pre-surgical orthodontics took 24.4 months and postsurgical 6.4 months. Treatment duration (median) was in BSSO was 32.1, LeFort 1 30.1 and bimaxillary osteotomy 29.7 months. Orthodontic extractions were performed in 35 patients (19%). If the orthodontic treatment included tooth extraction, the duration of pre-surgical treatment was on average 10 months longer, which is a statistically highly significant difference (p pre-surgical orthodontic treatment prolong treatment time by an average of 8-9 months.

  16. Treatment for Acquired Apraxia of Speech: Examination of Treatment Intensity and Practice Schedule

    Science.gov (United States)

    Wambaugh, Julie L.; Nessler, Christina; Cameron, Rosalea; Mauszycki, Shannon C.

    2013-01-01

    Purpose: The authors designed this investigation to extend the development of a treatment for acquired apraxia of speech (AOS)--sound production treatment (SPT)--by examining the effects of 2 treatment intensities and 2 schedules of practice. Method: The authors used a multiple baseline design across participants and behaviors with 4 speakers with…

  17. Treatment strategies for transuranic wastes

    International Nuclear Information System (INIS)

    Schneider, K.J.; Ross, W.A.; Swanson, J.L.; Allen, R.P.; Yasutake, K.M.

    1986-01-01

    This paper presents an analysis of treatment options or strategies for transuranic wastes expected to be generated at a commercial nuclear fuel reprocessing plant. Six potential options were analyzed, ranging from no treatment to maximum volume reduction and high quality waste forms. Economics for the total management of these wastes (treatment, transportation, disposal) indicate life-cycle savings for extensive treatment are as high as $1.7 billion for 70,000 MTU. Evaluations of the waste processing and waste forms support the selection of a number of the extensive waste treatments. It is concluded that there are significant incentives for extensive treatment of transuranic wastes

  18. Canadian Treatment Guidelines on Psychosocial Treatment of Schizophrenia in Children and Youth.

    Science.gov (United States)

    Lecomte, Tania; Abidi, Sabina; Garcia-Ortega, Iliana; Mian, Irfan; Jackson, Kevin; Jackson, Kim; Norman, Ross

    2017-09-01

    A panel of experts, including researchers, clinicians and people with lived experience, was brought together to develop the new Canadian schizophrenia guidelines for the psychosocial treatment of children and youth with schizophrenia or psychotic disorders. The ADAPTE process, which relies on adapting existing high-quality guidelines, was used. Existing guidelines for children and youth (mostly from the National Institute for Health and Care Excellence [NICE]), as well as CPA adult guidelines, were reviewed and discussed in terms of their adaptability to the Canadian context and their level of recommendation for children and youth. New treatments were also considered when recent meta-analyses suggested their usefulness. The children and youth psychosocial guidelines include many cross-sectional recommendations in terms of clinical and interpersonal skills needed to work with this clientele, setting and collaboration issues and needed adaptations for specific subpopulations. In terms of specific treatments, the treatments most strongly recommended are family intervention and cognitive behavior therapy. Also recommended, although with different degrees of support, are supported employment/supported education programs, patient education, cognitive remediation, and social skills training. Novel and upcoming psychosocial treatments are also briefly discussed. These novel Canadian guidelines for the psychosocial treatment of children and youth with schizophrenia or psychotic disorders report evidence-based treatments as well as important considerations for providers who work with this clientele. More studies with children and youth with schizophrenia and psychotic disorders are warranted. If followed, these guidelines should facilitate the recovery of children and youth with schizophrenia or psychotic disorders as well as the recovery of their families.

  19. Telemedicine of family-based treatment for adolescent anorexia nervosa: A protocol of a treatment development study.

    Science.gov (United States)

    Anderson, Kristen E; Byrne, Catherine; Goodyear, Alexandria; Reichel, Ryan; Le Grange, Daniel

    2015-01-01

    Family-based treatment is an efficacious treatment available for adolescents with anorexia nervosa. Yet the implementation of this treatment, at least in the United States, is challenging due to a limited number of trained family-based treatment therapists and the concentration of these therapists in a limited number of urban centers. The use of telemedicine in the delivery of family-based treatment can increase access to this therapy for this patient population. This two-year treatment development study (December 2013-November 2015) follows a two-wave iterative case series design. The study is ongoing and addresses the treatment needs of families in remote, rural, or underrepresented parts of the United States by delivering family-based treatment via telemedicine (video chat). The first six months of the study was dedicated to selecting a cloud-based secure telemedicine portal for use with participants. Recruitment for the first of two consecutive case series (N = 5) began during month seven. After these five patients completed treatment, a systematic review of treatment via feedback from participants and therapists related to the delivery of this model and use of technology was completed. A second wave of recruitment is underway (N = 5). At the end of both waves (N = 10), and after a second review of treatment, we should be able to establish the feasibility and acceptability of family-based treatment delivered via telemedicine for this patient population. This study is the first attempt to deliver family-based treatment for adolescents with anorexia nervosa via telemedicine. If delivering family-based treatment in this format is feasible, it will provide access to an evidence-based treatment for families heretofore unable to participate in specialist treatment for their child's eating disorder.

  20. Psychological treatments for gambling disorder

    Directory of Open Access Journals (Sweden)

    Rash CJ

    2014-10-01

    Full Text Available Carla J Rash, Nancy M Petry Department of Medicine, University of Connecticut Health Center, Farmington, CT, USA Abstract: This review discusses the research evidence for psychological treatment of gambling disorder. Several treatment options for gamblers have been explored, ranging from self-help and peer support, to brief and motivational interventions, to more intensive therapy approaches. Involvement in peer support programs seems to be optimal when combined with professional treatment; however, engagement and retention in peer support is limited. Self-directed interventions appear to benefit some gamblers; however, the involvement of therapist support, either in person or by telephone, may bolster these effects and such support need not be extensive. These self-directed options reduce the barriers associated with treatment-seeking, and may reach a wider range of gamblers than professionally delivered treatments alone. Brief and motivational approaches similarly may extend treatment options to more gamblers, namely at-risk and problem gamblers and those not seeking treatment. Of more extensive therapies, no consistent benefit of one approach emerges, although cognitive–behavioral interventions have been most often applied. Overall, several treatments have been developed for gambling disorder and results are promising, but variability in findings suggests a need for further systematic evaluation. Keywords: gambling treatment, cognitive behavioral treatment, brief interventions, pathological gambling, problem gambling, behavioral addictions

  1. THE METHODS OF CHOLEDOCHOLITHIASIS TREATMENT

    Directory of Open Access Journals (Sweden)

    N. V. Merzlikin

    2015-01-01

    Full Text Available The methods of choledocholithiasis treatment, which are currently used in clinics of the Russian Federa-tion, has been presented. The problems of diagnosis and treatment of gallstones (GSD in individuals of different age groups are spotlighted. In the study of treatment of cholelithiasis and choledocholithiasis, including arising complications, it can be concluded that so far the ideal method of treatment of this pa-thology has not been found. Up to now, the majority of doctor’s main treatment is surgical removal of gall stones by some method or other.This article also considers a conservative approach (drug: antispasmodics (selective and nonselective, and non-pharmacological: treatment, diet, describes the criteria and assessment of the effectiveness of therapeutic interventions that help in the question of further treatment: the continuation of drug therapy or assignment of surgical treatment. Invasive techniques that are covered in the article, namely, a tech-nique of remote and endoscopic lithotripsy, are high-tech and in demand at the moment, which, along with high efficiency removal of a stone, reduced the number and severity of postoperative complications. Additionally, in the analysis of the features of a particular method of treatment, advantages and disadvantages of different treatment methods are described, indications and contraindications (absolute and relative together with complications, possible outcomes, and further prognosis are high-lighted. 

  2. Treatment accuracy of hypofractionated spine and other highly conformal IMRT treatments

    International Nuclear Information System (INIS)

    Sutherland, B.; Hanlon, P.; Charles, P.

    2011-01-01

    Full text: Spinal cord metastases pose difficult challenges for radiation treatment due to tight dose constraints and a concave PTY. This project aimed to thoroughly test the treatment accuracy of the Eclipse Treatment Planning System (TPS) for highly modulated IMRT treatments, in particular of the thoracic spine, using an Elekta Synergy Linear Accelerator. The increased understanding obtained through different quality assurance techniques allowed recommendations to be made for treatment site commissioning with improved accuracy at the Princess Alexandra Hospital (PAH). Three thoracic spine IMRT plans at the PAH were used for data collection. Complex phantom models were built using CT data, and fields simulated using Monte Carlo modelling. The simulated dose distributions were compared with the TPS using gamma analysis and DYH comparison. High resolution QA was done for all fields using the MatriXX ion chamber array, MapCHECK2 diode array shifted, and the EPlD to determine a procedure for commissioning new treatment sites. Basic spine simulations found the TPS overestimated absorbed dose to bone, however within spinal cord there was good agreement. High resolution QA found the average gamma pass rate of the fields to be 99.1 % for MatriXX, 96.5% for MapCHECK2 shifted and 97.7% for EPlD. Preliminary results indicate agreement between the TPS and delivered dose distributions higher than previously believed for the investigated IMRT plans. The poor resolution of the MatriXX, and normalisation issues with MapCHECK2 leads to probable recommendation of EPlD for future IMRT commissioning due to the high resolution and minimal setup required.

  3. Global response to HIV: treatment as prevention, or treatment for treatment?

    NARCIS (Netherlands)

    Sigaloff, Kim C. E.; Lange, Joep M. A.; Montaner, Julio

    2014-01-01

    The concept of "treatment as prevention" has emerged as a means to curb the global HIV epidemic. There is, however, still ongoing debate about the evidence on when to start antiretroviral therapy in resource-poor settings. Critics have brought forward multiple arguments against a "test and treat"

  4. Generic phytosanitary irradiation treatments

    International Nuclear Information System (INIS)

    Hallman, Guy J.

    2012-01-01

    The history of the development of generic phytosanitary irradiation (PI) treatments is discussed beginning with its initial proposal in 1986. Generic PI treatments in use today are 150 Gy for all hosts of Tephritidae, 250 Gy for all arthropods on mango and papaya shipped from Australia to New Zealand, 300 Gy for all arthropods on mango shipped from Australia to Malaysia, 350 Gy for all arthropods on lychee shipped from Australia to New Zealand and 400 Gy for all hosts of insects other than pupae and adult Lepidoptera shipped to the United States. Efforts to develop additional generic PI treatments and reduce the dose for the 400 Gy treatment are ongoing with a broad based 5-year, 12-nation cooperative research project coordinated by the joint Food and Agricultural Organization/International Atomic Energy Agency Program on Nuclear Techniques in Food and Agriculture. Key groups identified for further development of generic PI treatments are Lepidoptera (eggs and larvae), mealybugs and scale insects. A dose of 250 Gy may suffice for these three groups plus others, such as thrips, weevils and whiteflies. - Highlights: ► The history of phytosanitary irradiation (PI) treatments is given. ► Generic PI treatments in use today are discussed. ► Suggestions for future research are presented. ► A dose of 250 Gy for most insects may suffice.

  5. Adding an Internet-delivered treatment to an efficacious treatment package for opioid dependence.

    Science.gov (United States)

    Christensen, Darren R; Landes, Reid D; Jackson, Lisa; Marsch, Lisa A; Mancino, Michael J; Chopra, Mohit P; Bickel, Warren K

    2014-12-01

    To examine the benefit of adding an Internet-delivered behavior therapy to a buprenorphine medication program and voucher-based motivational incentives. A block-randomized, unblinded, parallel, 12-week treatment trial was conducted with 170 opioid-dependent adult patients (mean age = 34.3 years; 54.1% male; 95.3% White). Participants received an Internet-based community reinforcement approach intervention plus contingency management (CRA+) and buprenorphine or contingency management alone (CM-alone) plus buprenorphine. The primary outcomes, measured over the course of treatment, were longest continuous abstinence, total abstinence, and days retained in treatment. Compared to those receiving CM-alone, CRA+ recipients exhibited, on average, 9.7 total days more of abstinence (95% confidence interval [CI = 2.3, 17.2]) and had a reduced hazard of dropping out of treatment (hazard ratio = 0.47; 95% CI [0.26, 0.85]). Prior treatment for opioid dependence significantly moderated the additional improvement of CRA+ for longest continuous days of abstinence. These results provide further evidence that an Internet-based CRA+ treatment is efficacious and adds clinical benefits to a contingency management/medication based program for opioid dependence.

  6. Decision making in treatment strategy of AVMs. Treatment board system at Tohoku University

    International Nuclear Information System (INIS)

    Jokura, Hidefumi; Yoshimoto, Takashi

    1999-01-01

    Treatment of some large, deep-seated arteriovenous malformations is still a challenge to neurosurgeons. The recent development of non-invasive imaging modalities has increased the chance of finding asymptomatic AVM's, for which evaluation for treatment is more complicated than in symptomatic cases. Currently there are 3 major treatment options for AVM: microsurgical removal, radiosurgery, and intravascular embolization. It is not easy to choose the best single modality or combination of modalities for individual patients, who have different types of onset, neurological deficits, size and location, and social background. After the installation of the Gamma Knife in November 1991, we established an 'AVM Treatment Board.' It comprises vascular neurosurgeons, endovascular neurosurgeons, and radio-neurosurgeons, and meetings are held twice a month. Every AVM case referred to us is presented to the board, and treatment strategy is selected after a discussion among experts who know the advantages and drawbacks of each treatment modality. We describe this board system in detail and emphasize the importance of gathering expertise in decision making. (author)

  7. Wastewater treatment

    Directory of Open Access Journals (Sweden)

    Ranđel N. Kitanović

    2013-10-01

    Full Text Available Quality of life on Earth in the future will largely depend on the amount of safe water. As the most fundamental source of life, water is relentlessly consumed and polluted. To halt this trend, many countries are taking extensive measures and investing substantial resources in order to stop the contamination of water and return at least tolerably good water quality to nature. The goal of water purification is to obtain clean water with the sewage sludge as a by-product. Clean water is returned to nature, and further treatment of sludge may be subject to other procedures. The conclusion of this paper is simple. The procedure with purified water is easily achievable, purified water is discharged into rivers, lakes and seas, but the problem of further treatment of sludge remains. This paper presents the basic methods of wastewater treatment and procedures for processing the products from contaminated water. The paper can serve as a basis for further elaboration. Water Pollution In order to ensure normal life of living creatures, the water in which they live or the water they use must have a natural chemical composition and natural features. When, as a result of human activities, the chemical composition of water and the ratio of its chemical elements significantly change, we say that water is polluted. When the pollutants come from industrial plants, we are talking about industrial wastewater, and when they come from households and urban areas, we are talking about municipal wastewater. Both contain a huge amount of pollutants that eventually end up in rivers. Then, thousands of defenseless birds, fish and other animals suffer, and environmental consequences become immeasurable. In addition, the waste fed to the water often ends up in the bodies of marine animals, so they can return to us as food. Thermal water pollution also has multiple effects on the changes in the wildlife composition of aquatic ecosystems. Polluted water can be purified by

  8. Management and treatment outcomes of patients enrolled in MDR-TB treatment in Viet Nam.

    Science.gov (United States)

    Phuong, N T M; Nhung, N V; Hoa, N B; Thuy, H T; Takarinda, K C; Tayler-Smith, K; Harries, A D

    2016-03-21

    The programmatic management of drug-resistant tuberculosis (TB) in Viet Nam has been rapidly scaled up since 2009. To document the annual numbers of patients enrolled for multidrug-resistant tuberculosis (MDR-TB) treatment during 2010-2014 and to determine characteristics and treatment outcomes of patients initiating treatment during 2010-2012. A retrospective cohort study using national reports and data from the national electronic data system for drug-resistant TB. The number of patients enrolled annually for MDR-TB treatment increased from 97 in 2010 to 1522 in 2014. The majority of patients were middle-aged men who had pulmonary disease and had failed a retreatment regimen; 77% had received ⩾2 courses of TB treatment. Favourable outcomes (cured and treatment completed) were attained in 73% of patients. Unfavourable outcomes included loss to follow-up (12.5%), death (8%) and failure (6.3%). Having had ⩾2 previous treatment courses and being human immunodeficiency virus-positive were associated with unfavourable outcomes. Increasing numbers of patients are being treated for MDR-TB each year with good treatment outcomes under national programme management in Viet Nam. However, there is a need to increase case detection-currently at 30% of the estimated 5100 MDR-TB cases per year, reduce adverse outcomes and improve monitoring and evaluation.

  9. Adherence to Polyethylene Glycol Treatment in Children with Functional Constipation Is Associated with Parental Illness Perceptions, Satisfaction with Treatment, and Perceived Treatment Convenience.

    Science.gov (United States)

    Koppen, Ilan Jasper Nader; van Wassenaer, Elsa A; Barendsen, Rinse W; Brand, Paul L; Benninga, Marc A

    2018-05-10

    To assess treatment adherence in children with functional constipation and to evaluate the association with parental beliefs about medication, illness perceptions, treatment satisfaction, and satisfaction with information about medication. A cross-sectional survey was administered among parents of children with functional constipation treated with polyethylene glycol. Adherence was measured via the Medication Adherence Report Scale (MARS-5, score 5-25), with greater scores indicating better adherence (scores ≥23 were defined as adherent). Beliefs about medication, illness perceptions, satisfaction with treatment, and satisfaction with information about treatment were measured with the Beliefs about Medication Questionnaire, the Brief Illness Perception Questionnaire, the Treatment Satisfaction Questionnaire for Medication (TSQM), and the Satisfaction with Information about Medication Questionnaire. Associations between the questionnaire scores and adherence (MARS-5 score as a continuous variable) were analyzed with regression analyses. In total, 43 of 115 included children (37%) were adherent (MARS-5 ≥23). Spearman rank correlation test revealed a statistically significant correlation between TSQM-convenience, TSQM-satisfaction, Brief Illness Perception Questionnaire question 8 (emotions), and the MARS-5 score (r s 0.342, P = .000; r s 0.258, P = .006; r s -0.192, P = .044), which suggests that parental perceived treatment convenience, satisfaction with treatment, and illness perceptions may affect adherence in children with functional constipation. In the hierarchical multivariate regression model, 22% of the variability of the MARS-5 score could be explained by the selected predictors. The TSQM-convenience score contributed the most to the model (β: 0.384, P = .000). Parents reported low adherence rates in their children with functional constipation. Treatment inconvenience, dissatisfaction with treatment, and the emotional impact of

  10. Treatment beliefs, health behaviors and their association with treatment outcome in type 2 diabetes

    DEFF Research Database (Denmark)

    von Arx, Lill-Brith Wium; Gydesen, Helge; Skovlund, Søren

    2016-01-01

    Objective: While the prevalence of type 2 diabetes is growing, it is increasingly well recognized that treatment outcomes in primary care practice are often suboptimal. The aim of this study is to examine the extent to which treatment beliefs and health behaviors predict diabetes health outcome......-reported survey administered to all insulin-treated people in the registry (n=3160). The survey was constructed to operationalize key concepts of diabetes management, diabetes treatment beliefs, and health behaviors. Results: In total, 1033 respondents answered the survey. The majority of treatment beliefs...... and health behaviors examined were predictors of glycemic control and, to a large extent, lipid profile. Absence from, or a low frequency of, self-measured blood glucose, non-adherence to general medical advice and the prescribed treatment, a low primary care utilization, and perceived low treatment efficacy...

  11. Treatment of mastitis during lactation.

    Science.gov (United States)

    Pyörälä, S

    2009-04-01

    Treatment of mastitis should be based on bacteriological diagnosis and take national and international guidelines on prudent use of antimicrobials into account. In acute mastitis, where bacteriological diagnosis is not available, treatment should be initiated based on herd data and personal experience. Rapid bacteriological diagnosis would facilitate the proper selection of the antimicrobial. Treating subclinical mastitis with antimicrobials during lactation is seldom economical, because of high treatment costs and generally poor efficacy. All mastitis treatment should be evidence-based, i.e., the efficacy of each product and treatment length should be demonstrated by scientific studies. Use of on-farm written protocols for mastitis treatment promotes a judicious use of antimicrobials and reduces the use of antimicrobials.

  12. Assessment and Treatment of Co-occurring Eating Disorders in Privately Funded Addiction Treatment Programs

    Science.gov (United States)

    Killeen, Therese K.; Greenfield, Shelly F.; Bride, Brian E.; Cohen, Lisa; Gordon, Susan Merle; Roman, Paul M.

    2011-01-01

    Privately-funded addiction treatment programs were surveyed to increase understanding of assessment and current treatment options for patients with co-occurring substance use and eating disorders. Data were collected from face-to-face interviews with program administrators of a nationally representative sample of 345 private addiction treatment programs. Although the majority of programs reported screening for eating disorders, programs varied in screening instruments used. Sixty-seven percent reported admitting cases of low severity. Twenty-one percent of programs attempt to treat eating disorders. These results highlight the need for education of addiction treatment professionals in assessment, referral and treatment of eating disorders. PMID:21477048

  13. Emerging from Depression: Treatment of Adolescent Depression Using the Major Treatment Models of Adult Depression.

    Science.gov (United States)

    Long, Kathleen M.

    Noting that adolescents who commit suicide are often clinically depressed, this paper examines various approaches in the treatment of depression. Major treatment models of adult depression, which can be directly applied to the treatment of the depressed adolescent, are described. Major treatment models and selected research studies are reviewed in…

  14. Portable treatment systems study

    Energy Technology Data Exchange (ETDEWEB)

    Sherick, M.J.; Schwinkendorf, W.E.; Bechtold, T.E.; Cole, L.T.

    1997-03-01

    In developing their Site Treatment Plans (STPs), many of the Department of Energy installations identified some form of portable treatment, to facilitate compliant disposition of select mixed low-level wastestreams. The Environmental Management Office of Science and Technology requested that a systems study be performed to better define the potential role of portable treatment with respect to mixed low-level waste, highlight obstacles to implementation, and identify opportunities for future research and development emphasis. The study was performed by first establishing a representative set of mixed waste, then formulating portable treatment system concepts to meet the required processing needs for these wastes. The portable systems that were conceptualized were evaluated and compared to a fixed centralized treatment alternative. The system evaluations include a life-cycle cost analysis and an assessment of regulatory, institutional, and technical issues associated with the potential use of portable systems. The results of this study show that when all costs are included, there are no significant cost differences between portable systems and fixed systems. However, it is also emphasized that many uncertainties exist that could impact the cost of implementing portable treatment systems. Portable treatment could be made more attractive through private sector implementation, although there is little economic incentive for a commercial vendor to develop small, specialized treatment capabilities with limited applicability. Alternatively, there may also be valid reasons why fixed units cannot be used for some problematic wastestreams. In any event, there are some site-specific problems that still need to be addressed, and there may be some opportunity for research and development to make a positive impact in these areas.

  15. Portable treatment systems study

    International Nuclear Information System (INIS)

    Sherick, M.J.; Schwinkendorf, W.E.; Bechtold, T.E.; Cole, L.T.

    1997-03-01

    In developing their Site Treatment Plans (STPs), many of the Department of Energy installations identified some form of portable treatment, to facilitate compliant disposition of select mixed low-level wastestreams. The Environmental Management Office of Science and Technology requested that a systems study be performed to better define the potential role of portable treatment with respect to mixed low-level waste, highlight obstacles to implementation, and identify opportunities for future research and development emphasis. The study was performed by first establishing a representative set of mixed waste, then formulating portable treatment system concepts to meet the required processing needs for these wastes. The portable systems that were conceptualized were evaluated and compared to a fixed centralized treatment alternative. The system evaluations include a life-cycle cost analysis and an assessment of regulatory, institutional, and technical issues associated with the potential use of portable systems. The results of this study show that when all costs are included, there are no significant cost differences between portable systems and fixed systems. However, it is also emphasized that many uncertainties exist that could impact the cost of implementing portable treatment systems. Portable treatment could be made more attractive through private sector implementation, although there is little economic incentive for a commercial vendor to develop small, specialized treatment capabilities with limited applicability. Alternatively, there may also be valid reasons why fixed units cannot be used for some problematic wastestreams. In any event, there are some site-specific problems that still need to be addressed, and there may be some opportunity for research and development to make a positive impact in these areas

  16. Addic tion treatment

    African Journals Online (AJOL)

    2009-01-29

    Jan 29, 2009 ... it does leave the profitability and viability of the more orthodox treatment centres at risk, and they now often seek improved income streams by sourcing patients from abroad. This effectively subsidises local patients whose treatment intervention is remunerated by discounted medical aid rates. South Africa is ...

  17. Duration of surgical-orthodontic treatment.

    Science.gov (United States)

    Häll, Birgitta; Jämsä, Tapio; Soukka, Tero; Peltomäki, Timo

    2008-10-01

    To study the duration of surgical-orthodontic treatment with special reference to patients' age and the type of tooth movements, i.e. extraction vs. non-extraction and intrusion before or extrusion after surgery to level the curve of Spee. The material consisted files of 37 consecutive surgical-orthodontic patients. The files were reviewed and gender, diagnosis, type of malocclusion, age at the initiation of treatment, duration of treatment, type of tooth movements (extraction vs. non-extraction and levelling of the curve of Spee before or after operation) and type of operation were retrieved. For statistical analyses two sample t-test, Kruskal-Wallis and Spearman rank correlation tests were used. Mean treatment duration of the sample was 26.8 months, of which pre-surgical orthodontics took on average 17.5 months. Patients with extractions as part of the treatment had statistically and clinically significantly longer treatment duration, on average 8 months, than those without extractions. No other studied variable seemed to have an impact on the treatment time. The present small sample size prevents reliable conclusions to be made. However, the findings suggest, and patients should be informed, that extractions included in the treatment plan increase chances of longer duration of surgical-orthodontic treatment.

  18. Radiation treatment of foodstuffs

    International Nuclear Information System (INIS)

    Luther, T.; Huebner, G.

    1990-10-01

    In addition to fundamental demands on radiation and safety engineering of irradiation facilities, the necessity arises to optimize irradiation conditions by using facilities to capacity and thus reducing irradiation costs. The following subjects are dealt with in detail: rehabilitation of a pilot plant for radiation treatment of onions; examination of radiation resistance of components and equipment parts of food irradiation facilities; chemical dosimetry; relative measurement of the intensity of radioactive sources; thermo- and chemiluminescence to prove irradiation of foodstuffs; radiation induced sprout inhibition of potatoes; laboratory tests of delayed maturation of tomatoes; radiation treatment of strawberries; radiation treatment of forage; radiation induced sprout inhibition of acid-treated onions; radiation treatment of starch and potatoe products; radiation treatment of cosmetics; the universal radiation source UNI 88/26 for gamma irradiation facilities; microbiological aspects of food irradiation, and introduction of chicken irradiation on an industrial scale. (BBR) [de

  19. Emerging treatments in alopecia.

    Science.gov (United States)

    Falto-Aizpurua, Leyre; Choudhary, Sonal; Tosti, Antonella

    2014-12-01

    Alopecia is a common concern encountered in the medical practice. Treatment approach varies according to the type and severity of alopecia. However, available treatment options have limited efficacy and several adverse effects. Presently, there are different treatment options being studied to overcome these limitations. Additionally, cellular pathways involved in the pathophysiology of alopecia are further being clarified to potentially target pathogenic molecules. We searched the literature for recently published articles discussing new treatment options as well as mechanisms involved in alopecia. We discuss the use of stem cells, growth factors, cellular pathways and robotic hair transplant, among other emerging therapies used for alopecia. Future looks very promising and new effective treatments such as janus kinase inhibitors could possibly be available for alopecia areata. The stem-cell technology is advancing and companies involved in hair follicle neogenesis are starting clinical trials on patients with androgenetic alopecia.

  20. Mandatory neurotechnological treatment: ethical issues.

    Science.gov (United States)

    Focquaert, Farah

    2014-02-01

    What if neurofeedback or other types of neurotechnological treatment, by itself or in combination with behavioral treatment, could achieve a successful "rewiring" of the psychopath's brain? Imagine that such treatments exist and that they provide a better long-term risk-minimizing strategy compared to imprisonment. Would it be ethical to offer such treatments as a condition of probation, parole, or (early) prison release? In this paper, I argue that it can be ethical to offer effective, non-invasive neurotechnological treatments to offenders as a condition of probation, parole, or (early) prison release provided that: (1) the status quo is in no way cruel, inhuman, degrading, or in some other way wrong, (2) the treatment option is in no way cruel, inhuman, degrading, or in some other way wrong, (3) the treatment is in the best interests of the offender, and (4) the offender gives his/her informed consent.

  1. Herbal Treatment in Menopause

    Directory of Open Access Journals (Sweden)

    Cigdem Gun

    2015-12-01

    Full Text Available The digest has been prepared to review available clinical evidence on herbs used in treatment of menopause symptoms. Effectiveness of Humulus lupulus, Vitex agnus-castus, Dioskorea vilosa, Linum usitatissimum, Pinus pinaster, cruciferous vegetables, Cimicifuga racemosa L., Angelica sinensis, Oenothera biennis L., Hypericum perforatum L., Panax ginseng, Ginkgo biloba, Glycine soja, Trifolium pratense and Piper methysticum herbs were assessed for treatment of menopausal symptoms in the studies. Herbs used as alternative supplementary treatment for menopause symptoms have been found to have a limited effect. Thus more studies are warranted to assess effectiveness of herbal treatments for menopausal symptoms. [Archives Medical Review Journal 2015; 24(4.000: 520-530

  2. Treatment efficacy, treatment failures and selection of macrolide resistance in patients with high load of Mycoplasma genitalium during treatment of male urethritis with josamycin.

    Science.gov (United States)

    Guschin, Alexander; Ryzhikh, Pavel; Rumyantseva, Tatiana; Gomberg, Mikhail; Unemo, Magnus

    2015-02-03

    Azithromycin has been widely used for Mycoplasma genitalium treatment internationally. However, the eradication efficacy has substantially declined recent decade. In Russia, josamycin (another macrolide) is the recommended first-line treatment for M. genitalium infections, however, no data regarding treatment efficacy with josamycin and resistance in M. genitalium infections have been internationally published. We examined the M. genitalium prevalence in males attending an STI clinic in Moscow, Russia from December 2006 to January 2008, investigated treatment efficacy with josamycin in male urethritis, and monitored the M. genitalium DNA eradication dynamics and selection of macrolide resistance in M. genitalium during this treatment. Microscopy and real-time PCRs were used to diagnose urethritis and non-viral STIs, respectively, in males (n = 320). M. genitalium positive patients were treated with recommended josamycin regimen and treatment efficacy was monitored using quantitative real-time PCR. Macrolide resistance mutations were identified using sequencing of the 23S rRNA gene. Forty-seven (14.7%) males were positive for M. genitalium only and most (85.1%) of these had symptoms and signs of urethritis. Forty-six (97.9%) males agreed to participate in the treatment efficacy monitoring. All the pre-treatment M. genitalium specimens had wild-type 23S rRNA. The elimination of M. genitalium DNA was substantially faster in patients with lower pre-treatment M. genitalium load, and the total eradication rate was 43/46 (93.5%). Of the six patients with high pre-treatment M. genitalium load, three (50%) remained positive post-treatment and these positive specimens contained macrolide resistance mutations in the 23S rRNA gene, i.e., A2059G (n = 2) and A2062G (n = 1). M. genitalium was a frequent cause of male urethritis in Moscow, Russia. The pre-treatment M. genitalium load might be an effective predictor of eradication efficacy with macrolides (and possibly

  3. The treatment of hyperthyroidism

    International Nuclear Information System (INIS)

    Klopper, J.F.

    1991-01-01

    The clinical picture of hyperthyroidism varies considerably and the diagnosis can easily be missed. The treatment of hyperthyroidism needs to be individualized, taking the patient's condition and preferences into account. There are three possible methods of treating hyperthyroidism, namely, medical treatment, including the use of beta-blockers and other antithyroid medications; surgery, and radio-iodine treatment. These three methods are briefly discussed. 3 refs., 3 tabs

  4. Surgical treatment of brain metastases - a review. Part 2. Results of treatment

    International Nuclear Information System (INIS)

    Wronski, M.; Czernicki, Z.

    1994-01-01

    Results of treatment of most frequent brain metastases from nonsmall cell lung cancer, breast cancer, malignant melanoma and kidney tumors are discussed. Also efficacy of surgical treatment, chemotherapy, radiotherapy and radiosurgery is analyzed

  5. Treatment of mastitis during lactation

    Directory of Open Access Journals (Sweden)

    Pyörälä S

    2009-04-01

    Full Text Available Abstract Treatment of mastitis should be based on bacteriological diagnosis and take national and international guidelines on prudent use of antimicrobials into account. In acute mastitis, where bacteriological diagnosis is not available, treatment should be initiated based on herd data and personal experience. Rapid bacteriological diagnosis would facilitate the proper selection of the antimicrobial. Treating subclinical mastitis with antimicrobials during lactation is seldom economical, because of high treatment costs and generally poor efficacy. All mastitis treatment should be evidence-based, i.e., the efficacy of each product and treatment length should be demonstrated by scientific studies. Use of on-farm written protocols for mastitis treatment promotes a judicious use of antimicrobials and reduces the use of antimicrobials.

  6. TECHNOLOGICAL PROCESS ASSESSMENT OF THE DRINKING WATER TREATMENT AT TARGU-MURES WATER TREATMENT PLANT

    Directory of Open Access Journals (Sweden)

    CORNELIA DIANA HERTIA

    2011-03-01

    Full Text Available This paper intends to assess the technological process of obtaining drinking water at Targu-Mures water treatment plant. The assessment was performed before changing the technological process and four months were chosen to be analized during 2008: January, April, July and October for its efficiency analysis on treatment steps. Mures River is the water source for the water treatment plant, being characterized by unsteady flow and quality parameters with possible important variability in a very short period of time. The treatment technological process is the classic one, represented by coagulation, sedimentation, filtration and disinfection, but also prechlorination was constantly applied as additional treatment during 2008. Results showed that for the measured parameters, raw water at the water treatment plant fits into class A3 for surface waters, framing dictated by the bacterial load. The treatment processes efficiency is based on the performance calculation for sedimentation, filtration, global and for disinfection, a better conformation degree of technological steps standing out in January in comparison to the other three analyzed months. A variable non-compliance of turbidity and residual chlorine levels in the disinfected water was observed constantly. Previous treatment steps managed to maintain a low level of oxidisability, chlorine consumption and residual chlorine levels being also low. 12% samples were found inconsistent with the national legislation in terms of bacteriological quality. Measures for the water treatment plant retechnologization are taken primarily for hyperchlorination elimination, which currently constitutes a discomfort factor (taste, smell, and a generating factor of chlorination by-products.

  7. Surgical Treatment of Tattoo Complications.

    Science.gov (United States)

    Sepehri, Mitra; Jørgensen, Bo

    2017-01-01

    With a continuing increase in the number of tattoos performed worldwide, the need to treat tattoo complications is growing. Earlier treatments of chronic inflammatory tattoo reactions were dominated by a medical approach, or with no active intervention. In this chapter, we will address modern surgical approaches applied to situations when medical treatment is inefficient and lasers are not applicable. Dermatome shaving is positioned as first-line treatment of allergic tattoo reactions and also indicated in a number of other tattoo reactions, supplemented with excision in selected cases. The methods allow fundamental treatment with removal of the culprit pigment from the dermis. The different instruments, surgical methods, and treatment schedules are reviewed, and a guide to surgeons is presented. Postoperative treatments and the long-term outcomes are described in detail. An algorithm on specialist treatment and follow-up of tattoo reactions, which can be practiced in other countries, is presented. © 2017 S. Karger AG, Basel.

  8. 7 CFR 305.5 - Treatment requirements.

    Science.gov (United States)

    2010-01-01

    ... inside of the treatment enclosure to uniformly distribute gas throughout the enclosure. The circulation... 7 Agriculture 5 2010-01-01 2010-01-01 false Treatment requirements. 305.5 Section 305.5... SERVICE, DEPARTMENT OF AGRICULTURE PHYTOSANITARY TREATMENTS Chemical Treatments § 305.5 Treatment...

  9. Involuntary admission may support treatment outcome and motivation in patients receiving assertive community treatment.

    Science.gov (United States)

    Kortrijk, Hans Erik; Staring, A B P; van Baars, A W B; Mulder, C L

    2010-02-01

    Patients with severe mental illness who are treated in assertive community treatment (ACT) teams are sometimes involuntarily admitted when they are dangerous to themselves or others, and are not motivated for treatment. However, the consequences of involuntary admission in terms of psychosocial outcome and treatment motivation are largely unknown. We hypothesized that involuntary admission would improve psychosocial outcome and not adversely affect their treatment motivation. In the context of routine 6-monthly outcome monitoring in the period January 2003-March 2008, we used the Health of the Nation Outcome Scales (HoNOS) and a motivation-for-treatment scale to assess 260 severely mentally ill patients at risk for involuntary admission. Mixed models with repeated measures were used for data analyses. During the observation period, 77 patients (30%) were involuntarily admitted. Relative to patients who were not involuntarily admitted, these patients improved significantly in HoNOS total scores (F = 17,815, df = 1, p < 0.001) and in motivation for treatment (F = 28.139, df = 1, p < 0.001). Patients who were not involuntarily admitted had better HoNOS and motivation scores at baseline, but did not improve. Involuntary admission in the context of ACT was associated with improvements in psychosocial outcome and motivation for treatment. There are no indications that involuntary admission leads to deterioration in psychosocial outcome or worsening of motivation for treatment.

  10. Patient Characteristics Associated with HCV Treatment Adherence, Treatment Completion, and Sustained Virologic Response in HIV Coinfected Patients

    Directory of Open Access Journals (Sweden)

    Glenn Wagner

    2011-01-01

    Full Text Available Background. Hepatitis C (HCV treatment efficacy among HIV patients is limited by poor treatment adherence and tolerance, but few studies have examined the psychosocial determinants of treatment adherence and outcomes. Methods. Chart abstracted and survey data were collected on 72 HIV patients who had received pegylated interferon and ribavirin to assess correlates of treatment adherence, completion, and sustained virologic response (SVR. Results. Nearly half (46% the sample had active psychiatric problems and 13% had illicit drug use at treatment onset; 28% reported <100% treatment adherence, 38% did not complete treatment (mostly due to virologic nonresponse, and intent to treat SVR rate was 49%. Having a psychiatric diagnosis was associated with nonadherence, while better HCV adherence was associated with both treatment completion and SVR. Conclusions. Good mental health may be an indicator of HCV treatment adherence readiness, which is in turn associated with treatment completion and response, but further research is needed with new HCV treatments emerging.

  11. Wastewater sludge treatment at selected wastewater treatment plants of the region Banska Bystrica

    International Nuclear Information System (INIS)

    Samesova, D.; Mitterpach, J.; Martinkova, A.

    2014-01-01

    The management of sewage sludges in water treatment plants of Banska Bystrica region. The paper deals with the problems of sewage sludge in wastewater treatment plants, its origin and possibilities how to use it in accordance with the current legislation of the Slovak Republic. We described radioactive pollution of sewage sludges. The paper consists of review of sludge production and its usage in the Slovak Republic and in selected states of the European Union. The paper deals with the sludge treatment in selected wastewater treatment plants in Banska Bystrica region in the context of biogas production and its usage by the help of the electricity and heat production. (authors)

  12. The Impact of Early Substance Use Disorder Treatment Response on Treatment Outcomes Among Pregnant Women With Primary Opioid Use.

    Science.gov (United States)

    Tuten, Michelle; Fitzsimons, Heather; Hochheimer, Martin; Jones, Hendree E; Chisolm, Margaret S

    2018-03-13

    This study examined the impact of early patient response on treatment utilization and substance use among pregnant participants enrolled in substance use disorder (SUD) treatment. Treatment responders (TRs) and treatment nonresponders (TNRs) were compared on pretreatment and treatment measures. Regression models predicted treatment utilization and substance use. TR participants attended more treatment and had lower rates of substance use relative to TNR participants. Regression models for treatment utilization and substance use were significant. Maternal estimated gestational age (EGA) and baseline cocaine use were negatively associated with treatment attendance. Medication-assisted treatment, early treatment response, and baseline SUD treatment were positively associated with treatment attendance. Maternal EGA was negatively associated with counseling attendance; early treatment response was positively associated with counseling attendance. Predictors of any substance use at 1 month were maternal education, EGA, early treatment nonresponse, and baseline cocaine use. The single predictor of any substance use at 2 months was early treatment nonresponse. Predictors of opioid use at 1 month were maternal education, EGA, early treatment nonresponse, and baseline SUD treatment. Predictors of opioid use at 2 months were early treatment nonresponse, and baseline cocaine and marijuana use. Predictors of cocaine use at 1 month were early treatment nonresponse, baseline cocaine use, and baseline SUD treatment. Predictors of cocaine use at 2 months were early treatment nonresponse and baseline cocaine use. Early treatment response predicts more favorable maternal treatment utilization and substance use outcomes. Treatment providers should implement interventions to maximize patient early response to treatment.

  13. Compliance and treatment satisfaction of post menopausal women treated for osteoporosis. Compliance with osteoporosis treatment

    Directory of Open Access Journals (Sweden)

    Huas Dominique

    2010-08-01

    Full Text Available Abstract Background Adherence to anti-osteoporosis treatments is poor, exposing treated women to increased fracture risk. Determinants of poor adherence are poorly understood. The study aims to determine physician- and patient- rated treatment compliance with osteoporosis treatments and to evaluate factors influencing compliance. Methods This was an observational, cross-sectional pharmacoepidemiological study with a randomly-selected sample of 420 GPs, 154 rheumatologists and 110 gynaecologists practicing in France. Investigators included post-menopausal women with a diagnosis of osteoporosis and a treatment initiated in the previous six months. Investigators completed a questionnaire on clinical features, treatments and medical history, and on patient compliance. Patients completed a questionnaire on sociodemographic features, lifestyle, attitudes and knowledge about osteoporosis, treatment compliance, treatment satisfaction and quality of life. Treatment compliance was evaluated with the Morisky Medication-taking Adherence Scale. Variables collected in the questionnaires were evaluated for association with compliance using multivariate logistic regression analysis. Results 785 women were evaluated. Physicians considered 95.4% of the sample to be compliant, but only 65.5% of women considered themselves compliant. The correlation between patient and physician perceptions of compliance was low (κ: 0.11 [95% CI: 0.06 to 0.16]. Patient-rated compliance was highest for monthly bisphosphonates (79.7% and lowest for hormone substitution therapy (50.0%. Six variables were associated with compliance: treatment administration frequency, perceptions of long-term treatment acceptability, perceptions of health consequences of osteoporosis, perceptions of knowledge about osteoporosis, exercise and mental quality of life. Conclusion Compliance to anti-osteoporosis treatments is poor. Reduction of dosing regimen frequency and patient education may be useful

  14. Comparison of pre-treatment and post-treatment use of selenium in retinal ischemia reperfusion injury

    Directory of Open Access Journals (Sweden)

    Alper Yazici

    2015-04-01

    Full Text Available AIM: To investigate the effects of selenium in rat retinal ischemia reperfusion (IR model and compare pre-treatment and post-treatment use. METHODS: Selenium pre-treatment group (n=8 was treated with intraperitoneal (i.p. selenium 0.5 mg/kg for 7d and terminated 24h after the IR injury. Selenium post-treatment group (n=8 was treated with i.p. selenium 0.5 mg/kg for 7d after the IR injury with termination at the end of the 7d period. Sham group (n=8 received i.p. saline injections identical to the selenium volume for 7d with termination 24h after the IR injury. Control group (n=8 received no intervention. Main outcome measures were retina superoxide dismutase (SOD, glutathione (GSH, total antioxidant status (TAS, malondialdehyde (MDA, DNA fragmentation levels, and immunohistological apoptosis evaluation. RESULTS: Compared to the Sham group, selenium pre-treatment had a statistical difference in all parameters except SOD. Post-treatment selenium also resulted in statistical differences in all parameters except the MDA levels. When comparing selenium groups, the pre-treatment selenium group had a statistically higher success in reduction of markers of cell damage such as MDA and DNA fragmentation. In contrast, the post-selenium treatment group had resulted in statistically higher levels of GSH. Histologically both selenium groups succeeded to limit retinal thickening and apoptosis. Pre-treatment use was statistically more successful in decreasing apoptosis in ganglion cell layer compared to post-treatment use. CONCLUSION: Selenium was successful in retinal protection in IR injuries. Pre-treatment efficacy was superior in terms of prevention of tissue damage and apoptosis.

  15. Wastewater Characteristics, Treatment and Disposal

    OpenAIRE

    Von Sperling, Marcos

    2007-01-01

    "Wastewater Characteristics, Treatment and Disposal is the first volume in the series Biological Wastewater Treatment, presenting an integrated view of water quality and wastewater treatment. The book covers the following topics: wastewater characteristics (flow and major constituents) impact of wastewater discharges to rivers and lakes overview of wastewater treatment systems complementary items in planning studies. This book, with its clear and practical approach, lays the foundations f...

  16. Basic Principles of Wastewater Treatment

    OpenAIRE

    Von Sperling, Marcos

    2007-01-01

    "Basic Principles of Wastewater Treatment is the second volume in the series Biological Wastewater Treatment, and focusses on the unit operations and processes associated with biological wastewater treatment. The major topics covered are: microbiology and ecology of wastewater treatment reaction kinetics and reactor hydraulics conversion of organic and inorganic matter sedimentation aeration The theory presented in this volume forms the basis upon which the other books...

  17. Improving Treatment Adherence in Bipolar Disorder: A Review of Current Psychosocial Treatment Efficacy and Recommendations for Future Treatment Development

    Science.gov (United States)

    Gaudiano, Brandon A.; Weinstock, Lauren M.; Miller, Ivan W.

    2008-01-01

    Treatment adherence is a frequent problem in bipolar disorder, with research showing that more than 60% of bipolar patients are at least partially nonadherent to medications. Treatment nonadherence is consistently predictive of a number of negative outcomes in bipolar samples, and the discontinuation of mood stabilizers places these patients at…

  18. Influences of mechanical pre-treatment on the non-biological treatment of municipal wastewater by forward osmosis

    DEFF Research Database (Denmark)

    Hey, Tobias; Zarebska, Agata; Bajraktari, Niada

    2016-01-01

    municipal wastewater treatment without the biological treatment step, including the effects of different pre-treatment configurations, e.g., direct membrane filtration before forward osmosis. Forward osmosis was tested using raw wastewater and wastewater subjected to different types of mechanical pre-treatment......, e.g., microsieving and microfiltration permeation, as a potential technology for municipal wastewater treatment. Forward osmosis was performed using thin-film-composite, Aquaporin Inside(TM) and HTI membranes with NaCl as the draw solution. Both types of forward osmosis membranes were tested......-sized wastewater treatment plants....

  19. Stroke Prevention & Treatment: Diet & Nutrition

    Science.gov (United States)

    ... Prevention & Treatment: Diet & Nutrition Stroke Prevention & Treatment: Diet & Nutrition A healthy diet can reduce your risk for ... Treatment How does a stroke affect eating and nutrition? Stroke can devastate a person's nutritional health because ...

  20. Treatment Options for Wilms Tumor

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... come back) after it has been treated. Treatment Option Overview Key Points There are different types of ...

  1. Treatment Options for Myelodysplastic Syndromes

    Science.gov (United States)

    ... special light. Certain factors affect prognosis and treatment options. The prognosis (chance of recovery) and treatment options ... age and general health of the patient. Treatment Option Overview Key Points There are different types of ...

  2. Treatment Option Overview (Prostate Cancer)

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... or in other parts of the body. Treatment Option Overview Key Points There are different types of ...

  3. Treatment Option Overview (Myelodysplastic Syndromes)

    Science.gov (United States)

    ... special light. Certain factors affect prognosis and treatment options. The prognosis (chance of recovery) and treatment options ... age and general health of the patient. Treatment Option Overview Key Points There are different types of ...

  4. Treatment Option Overview (Esophageal Cancer)

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... or in other parts of the body. Treatment Option Overview Key Points There are different types of ...

  5. Treatment Option Overview (Childhood Rhabdomyosarcoma)

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... or in other parts of the body. Treatment Option Overview Key Points There are different types of ...

  6. Treatment Option Overview (Penile Cancer)

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... or in other parts of the body. Treatment Option Overview Key Points There are different types of ...

  7. Treatment Option Overview (Vulvar Cancer)

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... or in other parts of the body. Treatment Option Overview Key Points There are different types of ...

  8. Treatment Option Overview (Pancreatic Cancer)

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... or in other parts of the body. Treatment Option Overview Key Points There are different types of ...

  9. Treatment Option Overview (Adrenocortical Carcinoma)

    Science.gov (United States)

    ... affect the prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... or in other parts of the body. Treatment Option Overview Key Points There are different types of ...

  10. Treatment Options for Childhood Rhabdomyosarcoma

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... or in other parts of the body. Treatment Option Overview Key Points There are different types of ...

  11. Treatment Options for Kaposi Sarcoma

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... or in other parts of the body. Treatment Option Overview Key Points There are different types of ...

  12. Treatment Options for Childhood Craniopharyngioma

    Science.gov (United States)

    ... factors affect prognosis (chance of recovery) and treatment options. The prognosis (chance of recovery ) and treatment options ... the brain where it was first found. Treatment Option Overview Key Points There are different types of ...

  13. Optimizing patient treatment decisions in an era of rapid technological advances: the case of hepatitis C treatment.

    Science.gov (United States)

    Liu, Shan; Brandeau, Margaret L; Goldhaber-Fiebert, Jeremy D

    2017-03-01

    How long should a patient with a treatable chronic disease wait for more effective treatments before accepting the best available treatment? We develop a framework to guide optimal treatment decisions for a deteriorating chronic disease when treatment technologies are improving over time. We formulate an optimal stopping problem using a discrete-time, finite-horizon Markov decision process. The goal is to maximize a patient's quality-adjusted life expectancy. We derive structural properties of the model and analytically solve a three-period treatment decision problem. We illustrate the model with the example of treatment for chronic hepatitis C virus (HCV). Chronic HCV affects 3-4 million Americans and has been historically difficult to treat, but increasingly effective treatments have been commercialized in the past few years. We show that the optimal treatment decision is more likely to be to accept currently available treatment-despite expectations for future treatment improvement-for patients who have high-risk history, who are older, or who have more comorbidities. Insights from this study can guide HCV treatment decisions for individual patients. More broadly, our model can guide treatment decisions for curable chronic diseases by finding the optimal treatment policy for individual patients in a heterogeneous population.

  14. Biological treatment of Crohn's disease

    DEFF Research Database (Denmark)

    Nielsen, Ole Haagen; Bjerrum, Jacob Tveiten; Seidelin, Jakob Benedict

    2012-01-01

    Introduction of biological agents for the treatment of Crohn's disease (CD) has led to a transformation of the treatment paradigm. Several biological compounds have been approved for patients with CD refractory to conventional treatment: infliximab, adalimumab and certolizumab pegol (and...... natalizumab in several countries outside the European Union). However, despite the use of biologics for more than a decade, questions still remain about the true efficacy and the best treatment regimens - especially about when to discontinue treatment. Furthermore, a need for optimizing treatment...... with biologics still exists, as 20-40% of patients with CD (depending on selection criteria) do not have any relevant response to the current biological agents (i.e. primary failures). A better patient selection might maximize the clinical outcome while minimizing the complications associated with this type...

  15. Hippocampal sparing radiotherapy for pediatric medulloblastoma: impact of treatment margins and treatment technique.

    Science.gov (United States)

    Brodin, N Patrik; Munck af Rosenschöld, Per; Blomstrand, Malin; Kiil-Berthlesen, Anne; Hollensen, Christian; Vogelius, Ivan R; Lannering, Birgitta; Bentzen, Søren M; Björk-Eriksson, Thomas

    2014-04-01

    We investigated how varying the treatment margin and applying hippocampal sparing and proton therapy impact the risk of neurocognitive impairment in pediatric medulloblastoma patients compared with current standard 3D conformal radiotherapy. We included 17 pediatric medulloblastoma patients to represent the variability in tumor location relative to the hippocampal region. Treatment plans were generated using 3D conformal radiotherapy, hippocampal sparing intensity-modulated radiotherapy, and spot-scanned proton therapy, using 3 different treatment margins for the conformal tumor boost. Neurocognitive impairment risk was estimated based on dose-response models from pediatric CNS malignancy survivors and compared among different margins and treatment techniques. Mean hippocampal dose and corresponding risk of cognitive impairment were decreased with decreasing treatment margins (P < .05). The largest risk reduction, however, was seen when applying hippocampal sparing proton therapy-the estimated risk of impaired task efficiency (95% confidence interval) was 92% (66%-98%), 81% (51%-95%), and 50% (30%-70%) for 3D conformal radiotherapy, intensity-modulated radiotherapy, and proton therapy, respectively, for the smallest boost margin and 98% (78%-100%), 90% (60%-98%), and 70% (39%-90%) if boosting the whole posterior fossa. Also, the distance between the closest point of the planning target volume and the center of the hippocampus can be used to predict mean hippocampal dose for a given treatment technique. We estimate a considerable clinical benefit of hippocampal sparing radiotherapy. In choosing treatment margins, the tradeoff between margin size and risk of neurocognitive impairment quantified here should be considered.

  16. Treatment of textiles industrial wastewater by electron beam and biological treatment (sbr)

    International Nuclear Information System (INIS)

    Khomsaton Abu Bakar; Khairul Zaman Mohd Dahlan; Zulkafli Ghazali; Ting Teo Ming

    2008-08-01

    Study of treating textiles industrial wastewater with combined of electron beam and Tower Style Biological Treatment (TSB) was investigated in Korea. In this project, textiles wastewater was also treated with electron beam, but hybrid with Sequencing Batch Reactor (SBR). The purpose of this research is to develop combined electron beam treatment with existing biological treatment facility (SBR), of textile industries in Malaysia. The objectives of this project are to determine the effective irradiation parameter for treatment and to identify effective total retention time in SBR system. To achieve the objective, samples fill in polypropyle tray were irradiated at 1 MeV, 20 mA and 1 MeV ,5 mA at doses 11, 20, 30, 40 and 50 kGy respectively. Raw effluent and two series of irradiated effluent at 1 MeV 20 mA (11, 20, 30, 40 and 50 kGy) and 1 MeV 5 mA (11, 20, 30, 40 and 50 kGy) were then treated in SBR system. Samples were analysed at 6, 14 and 20 hrs after aeration in the SBR. The results show that, average reduction in BOD was about 2-11% after irradiated at 5 mA, and the percentage increased to 21-73% after treatment in SBR system. At 20 mA, BOD reduced to 7-29% during irradiation and the value increased to 57-87% after treatment in SBR system. (Author)

  17. Changes in different organic matter fractions during conventional treatment and advanced treatment

    Institute of Scientific and Technical Information of China (English)

    Chao Chen; Xiaojian Zhang; Lingxia Zhu; Wenjie He; Hongda Han

    2011-01-01

    XAD-8 resin isolation of organic matter in water was used to divide organic matter into the hydrophobic and hydrophilic fractions.A pilot plant was used to investigate the change in both fractions during conventional and advanced treatment processes.The treatment of hydrophobic organics (HPO), rather than hydrophilic organicas (HPI), should carry greater emphasis due to HPO's higher trihalomethane formation potential (THMFP) and haloacetic acid formation potential (HAAFP).The removal of hydrophobic matter and its transmission into hydrophilic matter reduced ultimate DBP yield during the disinfection process.The results showed that sand filtration, ozonation, and biological activated carbon (BAC) filtration had distinct influences on the removal of both organic fractions.Additionally, the combination of processes changed the organic fraction proportions present during treatment.The use of ozonation and BAC maximized organic matter removal efficiency, especially for the hydrophobic fraction.In sum, the combination of pre-ozonation,conventional treatment, and O3-BAC removed 48% of dissolved organic carbon (DOC), 60% of HPO, 30% of HPI, 63% of THMFP,and 85% of HAAFP.The use of conventional treatment and O3-BAC without pre-ozonation had a comparable performance, removing 51% of DOC, 56% of HPO, 45% of HPI, 61% of THMFP, and 72% of HAAFP.The effectiveness of this analysis method indicated that resin isolation and fractionation should be standardized as an applicable test to help assess water treatment process efficiency.

  18. Predicting Treatment Response for Oppositional Defiant and Conduct Disorder Using Pre-treatment Adrenal and Gonadal Hormones.

    Science.gov (United States)

    Shenk, Chad E; Dorn, Lorah D; Kolko, David J; Susman, Elizabeth J; Noll, Jennie G; Bukstein, Oscar G

    2012-12-01

    Variations in adrenal and gonadal hormone profiles have been linked to increased rates of oppositional defiant disorder (ODD) and conduct disorder (CD). These relationships suggest that certain hormone profiles may be related to how well children respond to psychological treatments for ODD and CD. The current study assessed whether pre-treatment profiles of adrenal and gonadal hormones predicted response to psychological treatment of ODD and CD. One hundred five children, 6 - 11 years old, participating in a randomized, clinical trial provided samples for cortisol, testosterone, dehydroepiandrosterone, and androstenedione. Diagnostic interviews of ODD and CD were administered up to three years post-treatment to track treatment response. Group-based trajectory modeling identified two trajectories of treatment response: 1) a High-response trajectory where children demonstrated lower rates of an ODD or CD diagnosis throughout follow-up, and 2) a Low-response trajectory where children demonstrated higher rates of an ODD or CD diagnosis throughout follow-up. Hierarchical logistic regression predicting treatment response demonstrated that children with higher pre-treatment concentrations of testosterone were four times more likely to be in the Low-response trajectory. No other significant relationship existed between pre-treatment hormone profiles and treatment response. These results suggest that higher concentrations of testosterone are related to how well children diagnosed with ODD or CD respond to psychological treatment over the course of three years.

  19. Cyanobacteria, Toxins and Indicators: Field Monitoring,Treatment Facility Monitoring and Treatment Studies

    Science.gov (United States)

    This presentation is a compilation of harmful algal bloom (HAB) related field monitoring data from the 2015 bloom season, treatment plant monitoring data from the 2013 and 2014 bloom seasons, and bench-scale treatment study data from 2015.

  20. Cancer treatment: dealing with pain

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000827.htm Cancer treatment - dealing with pain To use the sharing features ... test, can cause pain. Treatment. Many types of cancer treatments can cause pain, including chemotherapy , radiation , and surgery. ...