WorldWideScience

Sample records for hbsag abbott prism

  1. Application of a newly developed high-sensitivity HBsAg chemiluminescent enzyme immunoassay for hepatitis B patients with HBsAg seroclearance.

    Science.gov (United States)

    Shinkai, Noboru; Matsuura, Kentaro; Sugauchi, Fuminaka; Watanabe, Tsunamasa; Murakami, Shuko; Iio, Etsuko; Ogawa, Shintaro; Nojiri, Shunsuke; Joh, Takashi; Tanaka, Yasuhito

    2013-11-01

    We modified and automated a highly sensitive chemiluminescent enzyme immunoassay (CLEIA) for surface antigen (HBsAg) detection using a combination of monoclonal antibodies, each for a specific epitope of HBsAg, and by improving an earlier conjugation technique. Of 471 hepatitis B virus (HBV) carriers seen in our hospital between 2009 and 2012, 26 were HBsAg seronegative as determined by the Abbott Architect assay. The Lumipulse HBsAg-HQ assay was used to recheck those 26 patients who demonstrated seroclearance by the Abbott Architect assay. The performance of the Lumipulse HBsAg-HQ assay was compared with that of a quantitative HBsAg detection system (Abbott Architect) and the Roche Cobas TaqMan HBV DNA assay (CTM) (lower limit of detection, 2.1 log copies/ml) using blood serum samples from patients who were determined to be HBsAg seronegative by the Abbott Architect assay. Ten patients had spontaneous HBsAg loss. Of 8 patients treated with nucleotide analogues (NAs), two were HBsAg seronegative after stopping lamivudine therapy and 6 were HBsAg seronegative during entecavir therapy. Eight acute hepatitis B (AH) patients became HBsAg seronegative. Of the 26 patients, 16 were HBsAg positive by the Lumipulse HBsAg-HQ assay but negative by the Abbott Architect assay. The differences between the two assays in terms of detectable HBsAg persisted over the long term in the spontaneous loss group (median, 10 months), the NA-treated group (2.5 months), and the AH group (0.5 months). In 9 patients, the Lumipulse HBsAg-HQ assay detected HBsAg when HBV DNA was negative by the CTM assay. HBsAg was also detected by the Lumipulse HBsAg-HQ assay in 4 patients with an anti-HBs concentration of >10 mIU/ml, 3 of whom had no HBsAg escape mutations. The automatic, highly sensitive HBsAg CLEIA Lumipulse HBsAg-HQ is a convenient and precise assay for HBV monitoring.

  2. Comparison of serum HBsAg quantitation by four immunoassays, and relationships of HBsAg level with HBV replication and HBV genotypes.

    Directory of Open Access Journals (Sweden)

    Edouard Tuaillon

    Full Text Available BACKGROUND: The decline in hepatitis B virus surface antigen (HBsAg may be an early predictor of the viral efficacy of Hepatitis B virus (HBV therapy. The HBsAg levels obtained by different immunoassays now need comparing and the relationships between levels of HBsAg and HBV DNA alongside HBsAg and genotype must be evaluated. METHODOLOGY/PRINCIPAL FINDINGS: HBsAg levels were compared among 80 patients using the Abbott Architect assay, a commercial immunoassay approved for HBsAg detection and quantitation, and three other assays derived from immunoassays approved for HBsAg detection (manufactured by Diasorin, Bio-Rad and Roche. Good correlation was found between the Abbot vs. Diasorin, Bio-Rad and Roche assays with narrow 95% limits of agreement and small mean differences: -0.06 to 0.11, -0.09 log(10 IU/mL; -0.57 to 0.64, -0.04 log(10 IU/mL; -0.09 to 0.45, -0.27 log(10 IU/mL, respectively. These agreements were not affected by genotypes A or D. HBsAg was weakly correlated with HBV DNA, whatever the HBsAg assay used: Abbott, ρ = 0.36 p = 0.001, Diasorin ρ = 0.34, p = 0.002; Bio-Rad ρ = 0.37, p<0.001; or Roche ρ = 0.41, p<0.001. This relationship between levels of HBsAg and HBV DNA seemed to depend on genotypes. Whereas HBsAg (Abbott assay tended to correlate with HBV DNA for genotype A (ρ = 0.44, p = 0.02, no such correlation was significant for genotypes D (ρ = 0.29, p = 0.15. CONCLUSION/SIGNIFICANCE: The quantitation of HBsAg in routine clinical samples is comparable between the reference assay and the adapted assays with acceptable accuracy limits, low levels of variability and minimum discrepancy. While HBsAg quantitation is not affected by HBV genotype, the observed association between levels of HBsAg and HBV DNA seems genotype dependent.

  3. Application of a Newly Developed High-Sensitivity HBsAg Chemiluminescent Enzyme Immunoassay for Hepatitis B Patients with HBsAg Seroclearance

    OpenAIRE

    Shinkai, Noboru; Matsuura, Kentaro; Sugauchi, Fuminaka; Watanabe, Tsunamasa; Murakami, Shuko; Iio, Etsuko; Ogawa, Shintaro; Nojiri, Shunsuke; Joh, Takashi; Tanaka, Yasuhito

    2013-01-01

    We modified and automated a highly sensitive chemiluminescent enzyme immunoassay (CLEIA) for surface antigen (HBsAg) detection using a combination of monoclonal antibodies, each for a specific epitope of HBsAg, and by improving an earlier conjugation technique. Of 471 hepatitis B virus (HBV) carriers seen in our hospital between 2009 and 2012, 26 were HBsAg seronegative as determined by the Abbott Architect assay. The Lumipulse HBsAg-HQ assay was used to recheck those 26 patients who demonstr...

  4. Purification of HBsAg produced by the human hepatoma cell line PLC/PRE/5 by affinity chromatography using monoclonal antibodies and application for ELISA diagnostic.

    Science.gov (United States)

    Merten, O W; Reiter, S; Scheirer, W; Katinger, H

    1983-01-01

    The human cell line PLC/PRF/5 (5) was used for the production of hepatitis B surface antigen subtype ad (HBsAg ad) and purified by affinity chromatography (AC) with monoclonal antibodies (mAb). mAb to HBsAg from mouse ascites have been purified by Protein A - AC prior coupling to AH-Sepharose 4B (Pharmacia). The combined procedure of ammonium-sulphate-precipitation of HBsAg from culture supernatants and immunosorbent-AC leads to approx. 700-fold purification. ELISA results using the mAb and the HBsAg for diagnostics of human serum, positive for anti-HBsAg-antibodies correlate with the RIA (AUSAB, Abbott).

  5. The Performance of the Abbott i2000 for Measuring Serum Markers of Infectious Diseases.

    Science.gov (United States)

    Wang, Linchuan; Chen, Wei; Yu, Yan

    2017-01-01

    To date, there is a trend that the chemiluminescent microparticle immunoassays (CMIA) and electrochemiluminescence immunoassays (ECIA) technology gradually replacing the enzyme-linked immunosorbent assay (ELISA). But the performance such as the limit of quantitation (LOQ), precision, linear range of CMIA, or ECIA for serum markers of infectious diseases has rarely been reported. Using proficiency testing samples and standard materials, we confirmed the LOQ of the ELISA and the precision, linear range, LOQ, and instrument biases of the Abbott i2000 for eight serum markers. We used the Abbott i2000 and ELISAs to assess five HIV samples; the researchers were blinded to the true status of the samples. For the Abbott i2000, the coefficients of variation (CV) for the low, medium, and high concentration samples ranged from 1.06 to 12.74%, which were less than the allowable error; the linear ranges of HBsAg and HBsAb were 0.66-304.11 IU/ml and 8.16-1205.9 mIU/ml, respectively. For the Abbott i2000, the LOQs of HBsAg, HBsAb, HBeAg, HBeAb, HBcAb, anti-HCV, anti-TP, and anti-HIV were 0.026 IU/ml, 4 mIU/ml, 0.14 NCU/ml, 0.56 NCU/ml, 0.99 NCU/ml, 0.5 NCU/ml, 8.8 mIU/ml, and 1.92 NCU/ml, respectively, and these values were 0.16 IU/ml, 6.97 mIU/ml, 1.16 NCU/ml, 1.63 NCU/ml, 1.79 NCU/ml, 1.03 NCU/ml, 8.33 mIU/ml, and 1.3 NCU/ml, respectively, for the ELISA. When five HIV samples were blindly assessed, two cases were missed by the Abbott i2000 and the ELISA results were consistent with the expected results. The Abbott i2000 performed significantly better than the ELISA on HBV and HCV screening; however, for anti-TP and anti-HIV, the ELISA remained the preferred method. © 2016 Wiley Periodicals, Inc.

  6. HBsAg RIA QUICK and Anti-HBs RIA QUICK. Information of a new technique of radioimmunoassay of hepatitis B virus surface antigen and the corresponding antibody using kits by IMMUNO Vienna

    Energy Technology Data Exchange (ETDEWEB)

    Kselikova, M; Urbankova, J

    1985-11-01

    With regard to the high sensitivity of HBsAg and anti-HBs detection using kits HBsAg RIA QUICK and Anti-HBs RIA QUICK, and with regard to the excellent technical set-up which substantially reduces demands on manual work and eliminates the need to equip the department with a rinser, and also with regard to the lower price as compared with similar kits by Abbott Co., the above mentioned two kits will be imported to Czechoslovakia.

  7. Analysis of hepatitis B surface antigen (HBsAg) using high-sensitivity HBsAg assays in hepatitis B virus carriers in whom HBsAg seroclearance was confirmed by conventional assays.

    Science.gov (United States)

    Ozeki, Itaru; Nakajima, Tomoaki; Suii, Hirokazu; Tatsumi, Ryoji; Yamaguchi, Masakatsu; Kimura, Mutsuumi; Arakawa, Tomohiro; Kuwata, Yasuaki; Ohmura, Takumi; Hige, Shuhei; Karino, Yoshiyasu; Toyota, Joji

    2018-02-01

    We investigated the utility of high-sensitivity hepatitis B surface antigen (HBsAg) assays compared with conventional HBsAg assays. Using serum samples from 114 hepatitis B virus (HBV) carriers in whom HBsAg seroclearance was confirmed by conventional HBsAg assays (cut-off value, 0.05 IU/mL), the amount of HBsAg was re-examined by high-sensitivity HBsAg assays (cut-off value, 0.005 IU/mL). Cases negative for HBsAg in both assays were defined as consistent cases, and cases positive for HBsAg in the high-sensitivity HBsAg assay only were defined as discrepant cases. There were 55 (48.2%) discrepant cases, and the range of HBsAg titers determined by high-sensitivity HBsAg assays was 0.005-0.056 IU/mL. Multivariate analysis showed that the presence of nucleos(t)ide analog therapy, liver cirrhosis, and negative anti-HBs contributed to the discrepancies between the two assays. Cumulative anti-HBs positivity rates among discrepant cases were 12.7%, 17.2%, 38.8%, and 43.9% at baseline, 1 year, 3 years, and 5 years, respectively, whereas the corresponding rates among consistent cases were 50.8%, 56.0%, 61.7%, and 68.0%, respectively. Hepatitis B virus DNA negativity rates were 56.4% and 81.4% at baseline, 51.3% and 83.3% at 1 year, and 36.8% and 95.7% at 3 years, among discrepant and consistent cases, respectively. Hepatitis B surface antigen reversion was observed only in discrepant cases. Re-examination by high-sensitivity HBsAg assays revealed that HBsAg was positive in approximately 50% of cases. Cumulative anti-HBs seroconversion rates and HBV-DNA seroclearance rates were lower in these cases, suggesting a population at risk for HBsAg reversion. © 2017 The Japan Society of Hepatology.

  8. No response to hepatitis B vaccine in infants born to HBsAg(+) mothers is associated to the transplacental transfer of HBsAg.

    Science.gov (United States)

    Wang, Jing; He, Yingli; Jin, Dongfang; Liu, Jinfeng; Zheng, Jie; Yuan, Ningxia; Bai, Yun; Yan, Taotao; Yang, Yuan; Liu, Yong; Zhang, Shulin; Zhao, Yingren; Chen, Tianyan

    2017-08-01

    No or low hepatitis B (HB) vaccine response is more frequent in infants from HBsAg(+) mothers than those from HBsAg(-). Our previous study found temporary positivity of HBsAg in infants from HBsAg(+) mothers. In this study, we hypothesized that HBsAg in infant blunt immune response to standard hepatitis B vaccination. A total of 328 consecutive HBsAg(+) mothers and their offspring were enrolled. Blood samples were taken from mothers and their infants and quantified for HBsAg, anti-HBs titer and HBV DNA load concentration; Placenta samples were collected to stain for HBsAg. First, 6.7% infants (22/328) showed anti-HBs titer lower than 10 mIU/mL after HB vaccination (non-response to HB vaccine). HBsAg(+) newborns showed higher risk of non-response than HBsAg(-) infants (13.0% versus 5.0%, p = 0.016). Infants from high HBsAg titer mothers displayed higher risk of HBsAg positivity at birth than those from low titer mothers (45.3% versus 2.8%, p < 0.001). HBsAg titer in mothers of HBsAg(+) newborns was much higher than mothers of HBsAg(-) newborns (p < 0.001). All those data supported HBsAg can be transferred through placenta. Our hypothesis was further reinforced by immunostaining with specific antibody against HBsAg, a substantial higher prevalence (87.5% versus 30.8%, p = 0.024) and stronger immunostaining (p = 0.008) was demonstrated in HBsAg(+) group comparing with placenta of the HBsAg(-) group. No response to HB vaccine in infants of HBsAg(+) mothers was associated to the transplacental transfer of HBsAg.

  9. An illness in the family: Dr. Maude Abbott and her sister, Alice Abbott.

    Science.gov (United States)

    Brookes, Barbara

    2011-01-01

    This paper explores Maude Abbott's internationally significant career in medicine and her parallel commitment to caring for her sister, Alice Abbott. An examination of Abbott's life reveals the difficulties faced by an ambitious Canadian woman in medicine from the 1890s to the 1920s; difficulties compounded by caring for a sister with a mental illness. The Abbott archive suggests that it was far more difficult for a woman doctor to make the kind of sharp distinction between public and private life that might be expected of professional men.

  10. Breaking tolerance in hepatitis B surface antigen (HBsAg) transgenic mice by vaccination with cross-reactive, natural HBsAg variants

    DEFF Research Database (Denmark)

    Schirmbeck, Reinhold; Dikopoulos, Nektarios; Kwissa, Marcin

    2003-01-01

    Processing exogenous hepatitis B surface antigen (HBsAg) of the hepatitis B virus (HBV) generates the K(b)-binding S(208-215) epitope 1; processing endogenous HBsAg generates the K(b)-binding S(190-197) epitope 2. Cross-reactive CD8(+) T cell responses were primed to epitope 1 but not epitope 2...... HBs-tg mice showed reduced antigenemia. Hence, vaccination with natural HBsAg variants from different HBV sero/genotypes can prime cross-reactive, specific CD8(+) T cell immunity that breaks tolerance to HBsAg....

  11. ABT-773 (Abbott Laboratories).

    Science.gov (United States)

    Lawrence, L E

    2001-06-01

    ABT-773 is a macrolide antibacterial agent under development by Abbott Laboratories and Taisho Pharmaceutical Co Ltd for the potential treatment of bacterial infection [266579]. As of February 2001, ABT-773 had entered phase III trials in the US [398274]. Japanese phase II trials were expected to commence in June 2000 and a phase II trial is being designed for respiratory infections, with Abbott expecting filing in March 2002 [360455]. The bioavailability of ABT-773 in humans is unaffected by food [383228] and in a phase I, randomized, double-blind trial in healthy males only mild adverse effects, usually affecting the gastrointestinal system, were observed [383208]. Under an agreement, Abbott and Taisho are conducting joint research to discover new compounds; Abbott will have worldwide marketing, manufacturing and supply rights (except in Japan), and Taisho will receive royalties on Abbott's sales in consideration of granted rights. In Japan, the companies will co-market any resulting compounds [266579]. ABT-773 demonstrated good activity in vitro and in vivo against Streptococcus pneumoniae and Staphylococcus aureus [383229], [383231], and was highly potent even against macrolide-resistant [382149], [382150] and invasive [383782] S pneumoniae.

  12. [Clinical evaluation of a novel HBsAg quantitative assay].

    Science.gov (United States)

    Takagi, Kazumi; Tanaka, Yasuhito; Naganuma, Hatsue; Hiramatsu, Kumiko; Iida, Takayasu; Takasaka, Yoshimitsu; Mizokami, Masashi

    2007-07-01

    The clinical implication of the hepatitis B surface antigen (HBsAg) concentrations in HBV-infected individuals remains unclear. The aim of this study was to evaluate a novel fully automated Chemiluminescence Enzyme Immunoassay (Sysmex HBsAg quantitative assay) by comparative measurements of the reference serum samples versus two independent commercial assays (Lumipulse f or Architect HBsAg QT). Furthermore, clinical usefulness was assessed for monitoring of the serum HBsAg levels during antiviral therapy. A dilution test using 5 reference-serum samples showed linear correlation curve in range from 0.03 to 2,360 IU/ml. The HBsAg was measured in total of 400 serum samples and 99.8% had consistent results between Sysmex and Lumipulse f. Additionally, a positive linear correlation was observed between Sysmex and Architect. To compare the Architect and Sysmex, both methods were applied to quantify the HBsAg in serum samples with different HBV genotypes/subgenotypes, as well as in serum contained HBV vaccine escape mutants (126S, 145R). Correlation between the methods was observed in results for escape mutants and common genotypes (A, B, C) in Japan. Observed during lamivudine therapy, an increase in HBsAg and HBV DNA concentrations preceded the aminotransferase (ALT) elevation associated with drug-resistant HBV variant emergence (breakthrough hepatitis). In conclusion, reliability of the Sysmex HBsAg quantitative assay was confirmed for all HBV genetic variants common in Japan. Monitoring of serum HBsAg concentrations in addition to HBV DNA quantification, is helpful in evaluation of the response to lamivudine treatment and diagnosis of the breakthrough hepatitis.

  13. Clinical performance of a new hepatitis B surface antigen quantitative assay with automatic dilution

    Directory of Open Access Journals (Sweden)

    Ta-Wei Liu

    2015-01-01

    Full Text Available Hepatitis B virus surface antigen (HBsAg levels reflect disease status and can predict the clinical response to antiviral treatment; however, the emergence of HBsAg mutant strains has become a challenge. The Abbott HBsAg quantification assay provides enhanced detection of HBsAg and HBsAg mutants. We aimed to evaluate the performance of the Abbott HBsAg quantification assay with automatic sample dilutions (shortened as automatic Architect assay, compared with the Abbott HBsAg quantification assay with manual sample dilutions (shortened as manual Architect assay and the Roche HBsAg quantification assay with automatic sample dilutions (shortened as Elecsys. A total of 130 sera samples obtained from 87 hepatitis B virus (HBV-infected patients were collected to assess the correlation between the automatic and manual Architect assays. Among the 87 patients, 41 provided 42 sera samples to confirm the linearity and reproducibility of the automatic Architect assay, and find out the correlation among the Elecsys and two Architect assays. The coefficients of variation (0.44–9.53% and R2 = 0.996–1, which were both determined using values obtained from the automatic Architect assay, showed good reproducibility and linearity. Results of the two Architect assays demonstrated a feasible correlation (n = 130 samples; R = 0.898, p  0.93 in all cases. In conclusion, the correlation between the automatic and manual dilution Architect assays was feasible, particularly in the HBeAg-negative and low DNA groups. With lower labor costs and less human error than the manual version, the Abbott automatic dilution Architect assay provided a good clinical performance with regard to the HBsAg levels.

  14. Implementing "Abbott v. Burke": A Guide to the 2006 K-12 Abbott Regulations

    Science.gov (United States)

    Education Law Center, 2005

    2005-01-01

    Except for school construction, there is no legislation to guide implementation of the programs and reforms ordered by the New Jersey Supreme Court in the landmark "Abbott v. Burke" case. Instead, in its 1998 "Abbott V decision," the Supreme Court directed the Commissioner of Education to provide standards and procedures to…

  15. GAMBARAN ANTI HBc POSITIF PADA DONOR DARAH DENGAN HbsAG NEGATIF

    Directory of Open Access Journals (Sweden)

    Susila Sastri

    2009-09-01

    Full Text Available AbstrakPemeriksaan HBsAg saja untuk skrining hepatitis B (HBV belum dapat menjamin donor darah bebas dari HBV sehingga darah donor belum memenuhi persyaratan untuk ditransfusikan. Darah donor yang akan ditranfusikan hendaklah memenuhi syarat diantaranya donor tidak pernah menderita HBV. Skrining darah donor terhadap HBV pada PMI hanya dengan uji HBsAg saja dimana HBsAg akan negatif pada stadium HBV tertentu, pada hal donor menderita atau dalam masa penyembuhan HBV. Anti-HBc dapat memberi informasi tentang perjalanan HBV bila digabungkan dengan marker HBV lain dan anti-HBc bertahan lebih lama dalam darah dibandingkan dengan marker lain. Donor darah HBsAg negatif dengan anti-HBc positif dari beberapa penelitian terdahulu masih ada yang mengandung HBV-DNA dan dapat menularkan HBV.Telah dilakukan penelitian terhadap donor darah dengan melakukan uji anti-HBc secara deskriptif terhadap donor darah dengan HBsAg negatif (n=100 pada UTD PMI Cabang Padang secara cross sectional study. Sampel diambil secara proportional random sampling. Darah sampel adalah darah HBsAg negatif dengan VDRL, HVC, HIV  negatif , semuanya diperiksa dengan dengan ELISATujuan penelitian untuk melihat gambaran anti-HBc positif pada donor darah dengan HBsAg negatif dan melihat hubungan antara indeks HBsAg dengan indeks anti-HBc. Pemeriksaan anti-HBc dilakukan dengan ELISA, alat dan reagen keluaran yang sama.Hasil penelitian menunjukkan frekuensi anti-HBc positif pada donor darah dengan HBsAg negatif sebanyak 27%, terutama pada laki-laki berumur antara 20-29 tahun (44,4%. Terdapat korelasi positif antara indeks HBsAg negatif dengan indeks anti-HBc (r = 0,02. Anti-HBc positif banyak ditemukan pada indeks HBsAg negatif 0,21-0,60 (76%.Kesimpulan, darah donor dengan HBsAg negatif yang selama ini dianggap aman untuk transfusi terbukti masih mungkin menularkan HBV dengan ditemukannya anti-HBc yang positif. Karena itu perlu pemeriksaan lanjutan DNA HBV pada donor darah dengan HbsAg

  16. Evaluation of a semi-automatic radioimmunoassay for hepatitis B surface antigen (HBsAg)

    International Nuclear Information System (INIS)

    Vries, J. de; Kruining, J.; Heijtink, R.A.

    1983-01-01

    The recently developed semi-automatic Hepatube system was evaluated in comparison to another radioimmunoassay for the detection of hepatitis B surface antigen (HBsAg), the manual Ausria II-125 test. After incubation of serum in anti-HBs coated tubes, the Hepatube system uses a machine to wash the tubes and to add tracer. After a second incubation, tubes are washed again in the machine and are manually transferred to the #betta# counter. Two machines were used. Machine 1 had an undefined defect. Of 1490 samples tested, 69 (4.6%) gave false-positive results versus 11 (0.7%) in the Ausria II-125 test. Machine 2 had one false-positive result among 920 samples versus 5 in the Ausria II-125 test. The sensitivity was measured with reference panels from Wellcome and Abbott as well as in titration series. The Hepatube system was found to be a factor three less sensitive than the Ausria II-125 test. The Hepatube processor is easy to handle; radioactive material can be held at a distance during the whole procedure; waste material is limited and less voluminous than in the Ausria II-125 test. (Auth.)

  17. Screening of HBsAg and anti HCV from tertiary care, private and public sector hospitals

    International Nuclear Information System (INIS)

    Khan, R.A.W.; Ahmed, W.; Alam, S.E.; Arif, A

    2011-01-01

    Objectives: To find out the frequency of hepatitis B surface antigen and hepatitis C antibodies in patients referred from a tertiary care public sector hospital, other public sector and private hospitals of Karachi. Settings and duration: Pakistan Medical Research Council's Specialized Research Centre for Gastroenterology and Hepatology, at Jinnah Postgraduate Medical Centre Karachi from January to December 2009. Patients and Methods: A cross sectional study was conducted where patients were referred from different departments of Jinnah Postgraduate Medical Centre (tertiary care public sector hospital), other public sector hospitals, private hospitals and clinics for the screening of hepatitis B and C virus infection. Three ml blood was collected from each patient, serum separated and tested for HBsAg and Anti HCV using Abbott Murex fourth Generation ELISA kits. Results: A total of 2965 cases were referred in a year. Overall sero prevalence of HBsAg and Anti-HCV was 5.9% and 12.8% respectively. HBsAg positivity in patient referred from public sector hospitals was 5.8%, those from private hospitals/clinics were 7.2%, and self-referred patients was 5.6%. Anti HCV positivity rates amongst these cases were 12.5%, 16.7% and 8.5% respectively. Co-infection of hepatitis B virus and hepatitis C virus was seen in 0.9, 2.5 and 1.4% cases respectively. Breakdown of viral positivity within different departments of Jinnah Postgraduate Medical Centre Karachi showed HBsAg positivity of 7.1% in Medical department, 5.2% in Surgical department, 5.0% in Gynaecology department, 6.6% in other departments of Jinnah Postgraduate Medical Centre while, only 1.7% were positive from Pakistan Railway, hospital Anti HCV positivity was maximally (20.3%) seen in medical department followed by 14% in other departments, 10.9% in surgical department, 7.9% in gynaecology and 5.1% in railway hospital. Co-infection of HBV and HCV was seen in 2% cases referred from medical department, while rest of the

  18. [Comparison of the clinical performance of the ECLusys HBsAg II assay with the Lumipulse f and HISCL 2000-i HBsAg screening assays].

    Science.gov (United States)

    Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato

    2012-02-01

    We compared the ECLusys HBsAgII (ECL HBsAg) assay to the Lumipulse Forte (LPf HBsAg) and HISCL (HIS HBsAg) assays. Measurement of dilution panels for which the WHO HBsAg international reference panel was the parent specimen revealed that the ECL and HIS assays enabled detection to a theoretical level of 0.04 IU/mL, whereas the LPf assay enabled detection to a level of 0.08 IU/mL. In a specificity test using high RF positive specimens (n = 33), pregnancy specimens (n = 35), cytomegalovirus antibody positive specimens (n = 36), and high M protein positive specimens (n = 21) that were confirmed negative for HBsAg by the LPf assay, negative results were obtained for all specimens on the HIS assay, but the ECL assay yielded a positive result for one of the high RF positive specimens. This individual was suggested on further testing to be an HBV carrier who was strongly positive for HBc antibody. In HBsAg mutants detection test, the detection rate was 92.3% with the ECL assay and 69.2% with the HIS assay. In a correlation test using routinely collected clinical specimens (n = 155), including positive stock specimens, aside from the one case where the LPf assay gave a negative result but both the ECL and HIS assays gave positive results, all of the results were consistent for all specimens. The above results confirmed that the ECL assay is both highly sensitive and specific, and also enables a high rate of HBsAg mutant detection.

  19. HBsAg level and hepatitis B viral load correlation with focus on pregnancy

    Science.gov (United States)

    Belopolskaya, Maria; Avrutin, Viktor; Firsov, Sergey; Yakovlev, Alexey

    2015-01-01

    Background Viral load measurement is necessary to estimate mother-to-child transmission risk for women with chronic hepatitis B (CHB), however, it is expensive. The present study aimed to investigate the relationship between HBsAg and hepatitis B virus (HBV) DNA levels, and to determine potential applications of HBsAg level monitoring for estimating viral load. Methods 85 patients with CHB (31 pregnant women, 26 non-pregnant women, 28 men) were included in the study. HBV DNA level was measured by real-time PCR, and HBsAg level by chemiluminescent immunoassay method. Dependency between viral load and HBsAg level was determined by Spearman correlation coefficient ρ. Results The correlation between HBsAg and HBV DNA levels was significant for all patients [ρ=0.3762 (P<0.0005; n=85)]. In the group of pregnant women, a low (unmeasurable) HBV DNA level led to a decrease in the Spearman coefficient ρ. In almost all cases a low level of the HBsAg corresponded to a low HBV DNA level. Only 2 patients had a low level of HBsAg and a relatively high viral load. By contrast, a high HBsAg level was observed in patients both with high and low viral load. Conclusions Correlation between HBsAg and HBV DNA levels is significant. In most cases, a low level of HBsAg indicates a low HBV DNA level, whereas a high HBsAg level does not always correspond to a high viral load. The measurement of HBV DNA level is necessary for pregnant women with a high HBsAg level. PMID:26127004

  20. Low occurrence of HBsAg but high frequency of transient occult HBV infection in vaccinated and HBIG-administered infants born to HBsAg positive mothers.

    Science.gov (United States)

    Zhou, Shan; Li, Tingting; Allain, Jean-Pierre; Zhou, Bin; Zhang, Yuming; Zhong, Mei; Fu, Yongshui; Li, Chengyao

    2017-12-01

    The status of chronic and occult HBV infection (OBI) in neonatal hepatitis B vaccine and immunoglobulin (HBIG) vaccinated infants born to HBsAg+ mothers was investigated at a major hospital in China. Seventy-seven and 15 blood samples were collected in first or second follow-up detection from the vaccinated babies aged 3-36 months born to 43 HBsAg+ or plus 25 HBeAg+ mothers. HBV infection was analyzed between the paired baby and mother by serology and DNA analysis. Among 77 children born to 68 HBsAg+ mothers, 3.9% (3/77) were HBsAg+, and 36.4% (28/77) were HBV DNA+/HBsAg- (OBIs) by a single PCR, respectively. Thirteen of 28 HBV DNA+/HBsAg- samples were conformed by two PCRs or S sequence, which accounted for 16.9% (13/77) of children. Three HBsAg+ and six OBIs were genotyped in consistent with their mother's HBV strains. Of 77 babies' blood samples, anti-HBs reactivity varied slightly according to age groups, while passively transmitted anti-HBc reactivity declined from 100% high reactivity at age 3-5 months to mostly negative at age ≥12 months. Babies with apparent OBI had higher levels of anti-HBc and lower levels of anti-HBs than those without OBI but all eight OBI babies with second follow-up samples became HBV DNA negative beyond 1 year of age. The vaccinated infants born to HBsAg+ mothers presented the low rate of HBsAg occurrence as vaccination failure and high frequency of viral persistence in the form of transient OBIs since no evidence of active HBV infection occurred beyond 1 year of age. © 2017 Wiley Periodicals, Inc.

  1. "A Prairie Childhood" by Edith Abbott: An Excerpt from "The Children's Champion," a Biography of Grace Abbott

    Science.gov (United States)

    Sorensen, John

    2003-01-01

    Grace Abbott's courageous struggles--to protect the rights of immigrants, to increase the role of women in government, and to improve the lives of all children--are filled with adventurous tales of the remarkable human ability to seek out suffering and to do something about it. "A Prairie Childhood" is an excerpt from the Grace Abbott biography…

  2. Association of social class in HBsAg and hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Pervez, T.; Anwar, M. S.

    2001-01-01

    Objective: To find out the social class difference in relation to frequency of HBsAg and hepatocellular carcinoma in our population. Design: An analytical study. Place and Duration of Study: This study was conducted in Oncology Department, Services Hospital, Lahore from December 1997 to December 2000. Subjects and Methods: The HBsAg positive voluntary and apparently healthy blood donors were grouped into three, based on monthly income. Lower socioeconomic group and had monthly income less than 3,000 Pakistani rupees, middle socioeconomic group had monthly income between 3,000-10,000 rupees and upper socioeconomic group had income of more than 10,000 Pakistani rupees. On the same pattern patients suffering from hepatocellular carcinoma coming for treatment were also grouped. During this period, 1000 blood donors were screened for HBsAg and 95 biopsy proven liver cancer by causes were treated. Medical and demographic data of all subjects were recorded. HBsAg test was performed immuno-chromatographic technique using Daina Screen HBsAg kit manufactured by Dainabot Co. Ltd, Tokyo, Japan. Results: Patients from lower and middle social class had higher percentage (80% and 75%) of hepatocellular carcinoma as compared to higher social class (66.6%). In the healthy asymptomatic blood donors lower social class had higher (13.76%) HBsAg positively as compared to middle social class (11.25%) and higher social class (8.06%). Conclusion: Preventive measures should be taken in identifying and reducing factors predisposing high frequency of these conditions. (author)

  3. Detection of antibodies to hepatitis B core antigen using the Abbott ARCHITECT anti-HBc assay: analysis of borderline reactive sera.

    Science.gov (United States)

    Ollier, Laurence; Laffont, Catherine; Kechkekian, Aurore; Doglio, Alain; Giordanengo, Valérie

    2008-12-01

    Routine use of the automated chemiluminescent microparticle immunoassay Abbott ARCHITECT anti-HBc for diagnosis of hepatitis B is limited in case of borderline reactive sera with low signal close to the cut-off index. In order to determine the significance of anti-HBc detection when borderline reactivity occurs using the ARCHITECT anti-HBc assay, a comparative study was designed. 3540 serum samples collected over a 2-month period in the hospital of Nice were examined for markers of HBV infection (HBsAg, anti-HBs and anti-HBc). One hundred seven samples with sufficient volume and with borderline reactivity by the ARCHITECT assay were tested by two other anti-HBc assays, a microparticle enzyme immunoassay (MEIA, AxSYM Core, Abbott Laboratories, IL, USA) and an enzyme linked fluorescent assay (ELFA, VIDAS Anti-HBc Total II, bioMérieux, Lyon, France). Only 46 samples were confirmed by the AxSYM and the VIDAS assays. Additional serological information linked to patient history showed that the remaining samples (61) were false positives (11), had low titer of anti-HBc antibodies (13), or were inconclusive (37). This comparative study highlighted the existence of a grey zone around the cut-off index. Confirmative results through a different immunoassay are needed to confirm the diagnosis of HBV on borderline reactive sera using the ARCHITECT anti-HBc assay.

  4. Analýza marketingové komunikace divize Abbott Diabetes Care, spol. Abbott Laboratories, s.r.o.

    OpenAIRE

    Iblová, Mirka

    2009-01-01

    This dissertation discusses the analysis of marketing communication within Abbott Laboratories Ltd. division of Abbott Diabetes Care, which carry business within the market of pharmaceutical industry. Prior to the analysis, the focus is on the theoretical part of the traditional components of the communication mix. In the practical part, the theoretical knowledge is then applied to the chosen example of the company. On the basis of performed analysis, recommendations are proposed in order to ...

  5. Prevalence of HBsAg and anti-HBs among delivering women.

    Science.gov (United States)

    Sabău, M; Căpîlnă; Kiss, E

    1979-01-01

    A survey of 2,500 delivering women revealed a 7.6% incidence of past infection with hepatitis B virus (HBV) (HBsAg or anti-HBs). Only 5.9% of the anti-HBs-positive mothers had a possible history of parenteral exposure to hepatitis B and none of the 55 HBsAg carriers had such a history. The findings suggest that HBV is endemic and that it is probably spread in part by nonparenteral means. The high rates of HBsAg and anti-HBs point to the possible preventive value of routine screenings for this system among pregnant women.

  6. 77 FR 13232 - Abbott Laboratories; Filing of Food Additive Petition

    Science.gov (United States)

    2012-03-06

    .... FDA-2012-F-0138] Abbott Laboratories; Filing of Food Additive Petition AGENCY: Food and Drug... that Abbott Laboratories has filed a petition proposing that the food additive regulations be amended... given that a food additive petition (FAP 2A4788) has been filed by Abbott Laboratories, 3300 Stelzer Rd...

  7. Delayed clearance of serum HBsAg in compensated cirrhosis B

    DEFF Research Database (Denmark)

    Fattovich, G; Giustina, G; Sanchez-Tapias, J

    1998-01-01

    The aim of this study was to evaluate the incidence, prognostic factors and clinical significance of delayed clearance of serum HBsAg in compensated cirrhosis B.......The aim of this study was to evaluate the incidence, prognostic factors and clinical significance of delayed clearance of serum HBsAg in compensated cirrhosis B....

  8. Detection of hepatitis B surface antigen by solid phase radioimmunoassay and immunometric assay (using enhanced luminescence)

    International Nuclear Information System (INIS)

    Nicholson, S.; Efandis, T.; Gust, I.

    1991-01-01

    A study was performed to assess the sensitivity and specificity of the amerlite monoclonal immunoassay for detection of hepatitis B surface antigen (HBsAG) by comparison with the Abbott Ausria II radioimmunoassay (RI). Serial bleeds from 34 patients with acute or chronic hepatitis B were tested by both assays. The Abbott Ausria II assay detected HBsAG longer than the Amersham Amerlite assay on two occasions and earlier on one occasion. Twelve patients with low HBsAg positive results (confirmed by Ausria II) were tested by the Amerlite assay, four were repeatably positive, five repeatably negative and three gave borderline results (which on repeat testing were negative). A similar trend was seen when a panel of sera containing known concentrations of HBsAG was tested. Replicate testing of 10 specimens eight times showed very good reproducibility by the Amerlite assay. Overall, the specificity of both assays was comparable, however differences in sensitivity were observed. 3 tabs

  9. Abbott Infant Formula Recall

    Data.gov (United States)

    U.S. Department of Health & Human Services — This list includes products subject to recall since September 2010 related to infant formula distributed by Abbott. This list will be updated with publicly available...

  10. Low serum hyaluronic acid levels associated with spontaneous HBsAg clearance

    NARCIS (Netherlands)

    Harkisoen, S.; Arends, J. E.; van den Hoek, A.; van Erpecum, K. J.; Boland, G. J.; Hoepelman, A. I. M.

    2015-01-01

    Purpose The pathophysiological underlying mechanism of spontaneous HBsAg clearance in hepatitis B virus (HBV) infected patients is largely unknown. However, serum hyaluronic acid (sHA) plays a role in liver fibrosis progression and reversely could serve as a potential biomarker for HBsAg clearance.

  11. An observation on positive rate of HBsAg in the urine of patients suffering from positive serum HBsAg

    Energy Technology Data Exchange (ETDEWEB)

    Peixun, Lin; Mingzheng, Zeng; Xiaoling, Chai [Wuhan Eighth Municipal Hospital, HB (China). Dept. of Laboratory

    1989-08-01

    In 1983, the Virus Research Office of the Shanxi Research Insitute of Preventive Medicine found out the granules of hepatitis B virus from the urine of patients and proved that this kind of virus can be spread through the urine. With the help of self-developed method of radio immunoelectrophoresis, our research office has purified and concentrated the urine of the patients suffering from positive serum HBsAg (hepatitis B surface antigen). Among them 25 are male, and another 25 are female. The result shows that the positive rate of HBsAg accounts for 80%. This is of important significance to the care of urine specimens, the protection of experimentalists and the development of clinical medicine.

  12. The Abbott Districts in 2005-06: Progress and Challenges, Spring 2006

    Science.gov (United States)

    Hirsch, Lesley

    2006-01-01

    New Jersey's urban--or "Abbott"--schools have improved at the preschool and elementary school level, but lag when it comes to middle and high school performance. These are the key findings of an Abbott Indicators Project report entitled, "The Abbott Districts in 2005-06: Progress and Challenges." The report was prepared by…

  13. Expression of Hepatitis B virus surface antigen (HBsAg from genotypes A, D and F and influence of amino acid variations related or not to genotypes on HBsAg detection

    Directory of Open Access Journals (Sweden)

    Natalia M. Araujo

    Full Text Available The impact of hepatitis B virus (HBV genotypes on the sensitivity of surface antigen (HBsAg detection assays has been poorly investigated. Here, plasmids carrying consensus or variant coding sequences for HBV surface proteins from genotypes A, D and F, were constructed. HBsAg levels were evaluated in medium and extracts of transfected CHO cells by a commercial polyclonal-based assay. We show that HBsAg detection values of consensus forms from genotypes D and F were, respectively, 37% and 30% lower than those obtained by genotype A. However, the presence of two single variations, T143M in genotype A, and T125M in genotype D, produced a decrease of 44% and an increase of 34%, respectively, on HBsAg mean values in comparison with their consensus forms. In conclusion, HBsAg detection levels varied among HBV genotypes. However, unique amino acid substitutions not linked to genotypes, such as T125M and T143M described here, should have more implications in HBV immunological diagnostics than the set of variations characteristic of each HBV genotype.

  14. Abbott Opinions #1-5.

    Science.gov (United States)

    Education Law Center, Inc., Newark, NJ.

    This document contains the following "Abbott Opinions": (1) "Early Childhood Education"; (2) "Adequate School Facilities"; (3) "Supplemental Programs and Whole School Reform in Elementary Schools"; (4) "Supplemental Programs in Middle and High Schools"; and (5) "Planning Programs and Budgets…

  15. 77 FR 75610 - Foreign-Trade Zone 22-Chicago, IL, Notification of Proposed Production Activity, Abbott...

    Science.gov (United States)

    2012-12-21

    ..., Notification of Proposed Production Activity, Abbott Laboratories, Inc., AbbVie, Inc. (Pharmaceutical Production), North Chicago, IL, Area Abbott Laboratories, Inc. (Abbott) and AbbVie, Inc. (AbbVie) submitted a... Abbott facilities to AbbVie, now designated as Subzone 22S (S-66-2012). Abbott and Abbvie are now...

  16. Technology evaluation: ABT-510, Abbott.

    NARCIS (Netherlands)

    Westphal, J.R.

    2004-01-01

    ABT-510 is a small peptide thrombospondin-1 mimetic angiogenesis inhibitor under development by Abbott Laboratories for the potential treatment of solid tumors. ABT-510 is undergoing phase II clinical trials.

  17. Delta antibody radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Kselikova, M; Urbankova, J

    1985-11-15

    The principle and procedure are described of the radioimmunoassay of delta antibody (delta-Ab) using the ABBOTT ANTI-DELTA kit by Abbott Co. A description is given of the kit, the working procedure and the method of evaluation. The results are reported of the incidence of delta-Ab in sera of patients with viral hepatitis B, in haemophiliacs, carriers of the hepatitis B virus surface antigen (HBsAg) and blood donors. The presence was detected of delta-Ab in one HBsAg carrier. The necessity is emphasized of delta-Ab determinations in the blood of donors in view of the antibody transfer with blood and blood preparations.

  18. FDA Abbott Infant Formula Recall

    Data.gov (United States)

    U.S. Department of Health & Human Services — On September 22, 2010, Abbott issued a voluntary recall of certain Similac powdered infant formula after identifying a common warehouse beetle (both larvae and...

  19. Analytical and clinical evaluation of the Abbott RealTime hepatitis B sequencing assay.

    Science.gov (United States)

    Huh, Hee Jae; Kim, Ji-Youn; Lee, Myoung-Keun; Lee, Nam Yong; Kim, Jong-Won; Ki, Chang-Seok

    2016-12-01

    Long-term nucleoside analogue (NA) treatment leads to selection for drug-resistant mutations in patients undergoing hepatitis B virus (HBV) therapy. The Abbott RealTime HBV Sequencing assay (Abbott assay; Abbott Molecular Inc., Des Plaines, IL, USA) targets the reverse transcriptase region of the polymerase gene and as such has the ability to detect NA resistance-associated mutations in HBV. We evaluated the analytical performance of the Abbott assay and compared its diagnostic performance to that of a laboratory-developed nested-PCR and sequencing method. The analytical sensitivity of the Abbott assay was determined using a serially-diluted WHO International Standard. To validate the clinical performances of the Abbott assay and the laboratory-developed assay, 89 clinical plasma samples with various levels of HBV DNA were tested using both assays. The limit of detection of the Abbott assay, was 210IU/ml and it successfully detected mutations when the mutant types were present at levels ≥20%. Among 89 clinical specimens, 43 and 42 were amplification positive in the Abbott and laboratory-developed assays, respectively, with 87.6% overall agreement (78/89; 95% confidence interval [CI], 78.6-93.4). The Abbott assay failed to detect the minor mutant populations in two specimens, and therefore overall concordance was 85.3% (76/89), and the kappa value was 0.79 (95% CI, 0.67-0.90). The Abbott assay showed comparable diagnostic performance to laboratory-developed nested PCR followed by direct sequencing, and may be useful as a routine method for detecting HBV NA resistance-associated mutations in clinical laboratory settings. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Reactivation of hepatitis B virus infection with persistently negative HBsAg on three HBsAg assays in a lymphoma patient undergoing chemotherapy.

    Science.gov (United States)

    Cheung, Wing-I; Chan, Henry Lik-Yuen; Leung, Vincent King-Sun; Tse, Chi-Hang; Fung, Kitty; Lin, Shek-Ying; Wong, Ann; Wong, Vincent Wai-Sun; Chau, Tai-Nin

    2010-02-01

    In patients with occult hepatitis B virus (HBV) infection, acute exacerbation may occur when they become immunocompromised. Usually, these patients develop hepatitis B surface antigen (HBsAg) seroreversion during the flare. Here we report on a patient with occult HBV infection, who developed HBV exacerbation after chemotherapy for diffuse large B-cell lymphoma. The resurgence of HBV DNA preceded the elevation of liver enzymes for 20 weeks. Atypically, despite high viraemia, serological tests showed persistently negative HBsAg using three different sensitive HBsAg assays (i.e., Architect, Murex and AxSYM). On comparing the amino acid sequence of the index patient with the consensus sequence, five mutations were found at pre-S1, five at pre-S2 and twenty-three mutations at the S region. Six amino acid mutations were located in the 'a' determinant, including P120T, K122R, M133T, F134L, D144A and G145A. The mutants K122R, F134L and G145A in our patient have not been tested for their sensitivity to Architect and Murex assays by the previous investigators and might represent the escape mutants to these assays.

  1. Comparative study of methods of detection of hepatitis ′B′ surface antigen (HBsAg.

    Directory of Open Access Journals (Sweden)

    Parab V

    1989-04-01

    Full Text Available The serum samples were collected from 52 patients of acute viral hepatitis and 235 hospital staff from Kasturba Hospital for Infectious Diseases. HBsAg was detected in their sera by counter-immuno-electrophoresis (CIEP, reverse passive hemogglutination (RPHA and by micro-enzyme-linked-immunosorbent assay (ELISA technique. Among the patients, HBsAg was detected in 12 cases (23% by CIEP, in 18 cases (34% by RPHA and in 23 patients (45% by ELISA. In the hospital staff, HBsAg was detected in 4 samples (1.7% by CIEP, in 8 samples (3.5% by RPHA and in 32 samples (13.5% by ELISA. Thus ELISA was found to be the most sensitive technique in detecting HBsAg.

  2. Collaborative evaluation of the Abbott yeast identification system.

    OpenAIRE

    Cooper, B H; Prowant, S; Alexander, B; Brunson, D H

    1984-01-01

    The Abbott yeast identification system (Abbott Laboratories, Diagnostics Division, Irving, Tex.) is a 24-h, instrumental method for identifying medically important yeasts, based on matrix analysis of 19 biochemical reactions and the germ tube test. The system was evaluated in two clinical laboratories by using 179 coded isolates, which included a high percentage of the less frequently encountered species. Based upon results with these coded isolates and from previously obtained laboratory dat...

  3. 78 FR 54487 - Abbott Laboratories; Diagnostic-Hematology; Including On-Site Leased Workers From Manpower...

    Science.gov (United States)

    2013-09-04

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-82,379] Abbott Laboratories... February 22, 2013, applicable to workers of Abbott Laboratories, Diagnostic--Hematology division, including... Clara, California location of Abbott Laboratories, Diagnostic--Hematology Division. The Department has...

  4. Abbott Students Attending Charter Schools: Funding Disparities and Legal Implications

    Science.gov (United States)

    Bulkley, Katrina

    2007-01-01

    Most of New Jersey's charter schools are located in the state's poorer, urban school districts, or "Abbott" districts, and exclusively serve students from those communities. A number of other schools are located outside of the Abbott districts but enroll students from these districts. Specifically, of the 50 charter schools operating in…

  5. Seroprevalence of HDV infection in HBsAg positive population in Ismailia, Egypt.

    Science.gov (United States)

    Gomaa, Nahed I M; Metwally, Lobna A; Nemr, Nader; Younis, Soha

    2013-01-01

    Hepatitis D virus (HDV) is a defective RNA virus that needs hepatitis B surface antigen (HBsAg) from HBV for transmission. HDV can lead to fulminant hepatitis and the progression of chronic liver damage in patients with chronic hepatitis B. The aim of this study was to determine the seroprevalence of HDV among HBsAg positive individuals in Ismailia, Egypt. Serum samples were collected from 170 HBsAg positive healthy individuals from Suez Canal University blood bank over a one year period. All of them were seeking blood donation and found to be HBsAg positive during viral hepatitis screening workups which is routinely done prior to donation. Serum samples were screened for IgG antibodies to hepatitis delta virus (HDV) using enzyme-linked immunosorbent assay (ELISA) method. Anti-HDV antibodies were detected in 8 (4.7%) individuals aged from 29-43 years. Liver function tests showed that serum ALT and AST levels were elevated in the HBsAglanti-HDV positive cases. It is concluded that the rate of HDV infection in Ismailia is high and further investigation is needed to validate the findings and raise awareness about the risk of dual HBV and HDV infection.

  6. 77 FR 4368 - Abbott Laboratories, Diagnostics Division, Including On-Site Leased Workers From Manpower...

    Science.gov (United States)

    2012-01-27

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-75,201] Abbott Laboratories..., applicable to workers of Abbott Laboratories, Diagnostics Division, including on-site leased workers from... (clerical) were employed on-site at the Irving, Texas location of Abbott Laboratories, Diagnostics Division...

  7. Ausab test - a radioimmunoassay in the solid phase for the detection of antibodies against HBsAg

    Energy Technology Data Exchange (ETDEWEB)

    Lange, W; Koehler, H; Apodaca, J [Bundesgesundheitsamt, Berlin (Germany, F.R.). Abt. fuer Virologie

    1974-01-01

    The suitability of a newly developed RIA (Ausab test, Abbott laboratories) for the detection of antibodies against the Hepatitis B (surface) antigen (HBsAg) has been tested on 1968 sera of blood donors. Reproducibility test and specificity test were included. During the examination the technique of the Ausab test was changed from the original one-step to the two-step procedure. With the one-step technique 431 of 1968 sera (21.9%) showed positive reactions. During the test problems concerning the differentiation between positive and negative results were encountered due to high unspecific binding of radioactivity. Positive sera were re-examined employing the two-step technique and only 77.4% of the previously positive reactions could be reproduced. 50 sera that were negative in the one-step test remained negative in the two-step test. Difficulties concerning nonspecific binding of radioactivity as observed with the one-step technique were not encountered with the two-step procedure. On 92 of the confirmed positive sera a specificity test was run and 90 (97.8%) proved to be specific. A calculated 16.5% of the blood donors in Berlin have to be considered as antibody carriers. Only 6 of the Ausab positive sera were found to give positive reactions in CEP. 3 sera that were initially positive in CEP could neither be confirmed in a repeated CEP nor in the Ausab test.

  8. Abbott Preschool Program Longitudinal Effects Study: Fifth Grade Follow-Up

    Science.gov (United States)

    Barnett, W. Steven; Jung, Kwanghee; Youn, Min-Jong; Frede, Ellen C.

    2013-01-01

    New Jersey's Abbott Preschool program is of broad national and international interest because the Abbott program provides a model for building a high-quality system of universal pre-K through public-private partnerships that transform the existing system. The program offers high-quality pre-K to all children in 31 New Jersey communities with high…

  9. 77 FR 16039 - Abbott Laboratories et al.; Withdrawal of Approval of 35 New Drug Applications and 64 Abbreviated...

    Science.gov (United States)

    2012-03-19

    ...] Abbott Laboratories et al.; Withdrawal of Approval of 35 New Drug Applications and 64 Abbreviated New... Tablets... Abbott Laboratories, PA77/Bldg. AP30-1E, 200 Abbott Park Rd., Abbott Park, IL 60064-6157. NDA... (diphenhydramine Healthcare. HCl)) Injection Preservative Free. NDA 010021 Placidyl Abbott Laboratories...

  10. Evaluation of Copan FLOQSwab for the molecular detection of Chlamydia trachomatis by Abbott RealTime CT PCR.

    Science.gov (United States)

    Coorevits, L; Vanscheeuwijck, C; Traen, A; Bingé, L; Ryckaert, I; Padalko, E

    2015-12-01

    We evaluated Copan FLOQSwabs next to Abbott swabs for the detection of Chlamydia trachomatis (CT) by Abbott RealTime PCR. We collected 1062 paired swabs from female sex workers. The study was divided in two arms, according to the order of swab collection. If the Abbott swab was collected first, 501 couples were concordant and two discordant (Abbott negative and Copan positive). If the Copan swab was collected first, 537 couples were concordant and 10 discordant (eight Abbott negative and Copan positive and two Abbott positive and Copan negative). All discordant samples contained low levels of C. trachomatis. Technical issues lead to retesting of 64 Copan and 21 Abbott swabs. Our results show that Copan FLOQSwabs can be used interchangeably with Abbott swabs. While appearing to have an advantage in detecting more positive samples, the use of Copan swabs led to a higher retesting rate due to technical errors.

  11. Delta infection evidenced by radioimmunoanalysis in selected collectives

    Energy Technology Data Exchange (ETDEWEB)

    Kselikova, M; Horejsi, J; Urbankova, J

    1987-01-01

    The presence of the Delta agent within the population was tested by means of the Delta-antibody radioimmunoassay using competitive kits of the firms ABBOTT (ABBOTT-ANTI-DELTA) and SORIN (AB-DELTAK). The Delta-antibody was found in 3.2% HBV patients, 5% HBsAg carriers, and in 20.8% of specific anti-Hbs-immunoglobulin. In hemophiliacs and blood donors no Delta-antibody was seen.

  12. Delta infection evidenced by radioimmunoanalysis in selected collectives

    International Nuclear Information System (INIS)

    Kselikova, M.; Horejsi, J.; Urbankova, J.

    1987-01-01

    The presence of the Delta agent within the population was tested by means of the Delta-antibody radioimmunoassay using competitive kits of the firms ABBOTT (ABBOTT-ANTI-DELTA) and SORIN (AB-DELTAK). The Delta-antibody was found in 3.2% HBV patients, 5% HBsAg carriers, and in 20.8% of specific anti-Hbs-immunoglobulin. In hemophiliacs and blood donors no Delta-antibody was seen. (author)

  13. 76 FR 47143 - Approval for Manufacturing Authority, Foreign-Trade Zone 153; Abbott Cardiovascular Systems, Inc...

    Science.gov (United States)

    2011-08-04

    ... Authority, Foreign-Trade Zone 153; Abbott Cardiovascular Systems, Inc., (Cardiovascular Devices), Riverside... of Abbott Cardiovascular Systems, Inc., within Sites 11-13 of FTZ 153, located in Riverside County... behalf of Abbott Cardiovascular Systems, Inc., as described in the application and Federal Register...

  14. The Ausab test - a radioimmunoassay in the solid phase for the detection of antibodies against HBsAg

    International Nuclear Information System (INIS)

    Lange, W.; Koehler, H.; Apodaca, J.

    1974-01-01

    The suitability of a newly developed RIA (Ausab test, Abbott laboratories) for the detection of antibodies against the Hepatitis B (surface) antigen (HBsAg) has been tested on 1968 sera of blood donors. Reproducibility test and specificity test were included. During the examination the technique of the Ausab test was changed from the original one-step to the two-step procedure. With the one-step technique 431 of 1968 sera (21.9%) showed positive reactions. During the test problems concerning the differentiation between positive and negative results were encountered due to high unspecific binding of radioactivity. Positive sera were re-examined employing the two-step technique and only 77.4% of the previously positive reactions could be reproduced. 50 sera that were negative in the one-step test remained negative in the two-step test. Difficulties concerning nonspecific binding of radioactivity as observed with the one-step technique were not encountered with the two-step procedure. On 92 of the confirmed positive sera a specificity test was run and 90 (97.8%) proved to be specific. A calculated 16.5% of the blood donors in Berlin have to be considered as antibody carriers. Only 6 of the Ausab positive sera were found to give positive reactions in CEP. 3 sera that were initially positive in CEP could neither be confirmed in a repeated CEP nor in the Ausab test. (orig.) [de

  15. Frequency of pregnant women with HBsAg in a Brazilian community Freqüência de gestantes portadoras do HBsAg em uma comunidade brasileira

    Directory of Open Access Journals (Sweden)

    Geraldo Duarte

    1997-01-01

    Full Text Available The work reported here points up the real benefits provided by neonatal immunoprophylaxis of newborns delivered by mothers who are seropositive for the hepatitis B virus surface antigen HBsAg and underscores the need to properly identify such mothers in Brazil so that immunoprophylaxis can be undertaken. To help determine levels of hepatitis B virus (HBV infection and seropositivity for various HBV markers among pregnant women in Southeast Brazil, investigators studied 7992 pregnant women delivering at the Clinical Hospital of the University of São Paulo's Ribeirão Preto School of Medicine in Ribeirão Preto, Brazil. Seroreactivity for HBsAg was determined first by serologic screening with an enzyme-linked immunosorbent assay (ELISA procedure in which the sera were incubated for 2 hours and then by confirmation with another ELISA in which the sera were incubated for 18 hours. Subsequently, tests for anti-HBsAg, HBeAg, anti-HBeAg, and anti-HBcAg markers were conducted using confirmed positive samples. Initial screening found 84 of the 7992 samples (1.05%, 95% CI: 0.84-1.30 to be positive for HBsAg; however, this HBsAg positivity was confirmed in only 76 (0.95%, 95% CI: 0.75-1.19. The positivity rate was significantly higher among subjects whose pregnancies terminated in miscarriage (1.84% than among those with live births (0.83% (chi2, Yates correction = 7.6; P = 0.005. Anamnesis was able to identify HBV risk factors in only 27.6% of the confirmed HBsAg-positive subjects or close household contacts. However, 21.3% (95% CI: 1.04-30.56 of the confirmed HBsAg-positive subjects were found positive for HBeAg, indicating a high risk of vertical transmission of the virus. These results demonstrate a need to conduct specific serologic research at term, in order to provide effective neonatal immunoprophylactic benefits.Visando aferir a tasa de reatividade sérica do HBsAg e de outros marcadores da infecção pelo VHB em parturientes, além de avaliar

  16. Evaluation of the Abbott ARCHITECT Toxo IgM assay.

    Science.gov (United States)

    Sickinger, Eva; Braun, Hans-Bertram; Praast, Gerald; Stieler, Myriam; Gundlach, Cordelia; Birkenbach, Claudia; Prostko, John; Palafox, Mary Ann; Frias, Edwin; Hsu, Stephen; Matias, Matthew; Pucci, Dominick; Hausmann, Michael; Sagel, Ulrich; Smith, Darwin

    2009-07-01

    Development of the ARCHITECT Toxo IgM assay has been done to assist the clinician in acute Toxoplasma gondii infection detection, especially in pregnant women. Its use, in conjunction with ARCHITECT Toxo IgG and Toxo Avidity assays, will provide an array of assays particularly useful in the monitoring of pregnant females to determine the risk of maternal transmission of the parasite. Specificity results from 2 testing sites, using populations of pregnant females, hospital patients, and blood donors, demonstrated that the assay has an overall resolved relative specificity of 99.89% (confidence interval, 99.68-99.98%). Relative specificity for pregnant female specimens was 99.95% (n = 2031). Excellent seroconversion sensitivity was observed for the ARCHITECT Toxo IgM assay, which was similar to the Abbott AxSYM Toxo IgM assay (Abbott Laboratories, Abbott Park, IL). In more than 90% of the panels tested, the 1st bleed detected in the serial bleeds was the same for both assays.

  17. The Abbott Preschool Program: Fifth Year Report on Enrollment and Budget

    Science.gov (United States)

    Applewhite, Erain; Hirsch, Lesley

    2003-01-01

    The New Jersey Supreme Court's 1998 ruling in Abbott v. Burke represents the first judicial directive in the nation that public education must include a high-quality, well-planned preschool program starting at age three. This decision applies to 30 urban school districts, known as the Abbott districts, that serve approximately 25 percent of the…

  18. Spontaneous HBsAg loss in Korean patients: relevance of viral genotypes, S gene mutations, and covalently closed circular DNA copy numbers

    Directory of Open Access Journals (Sweden)

    Kyun-Hwan Kim

    2014-09-01

    Full Text Available Background/AimsOccult HBV infection can persist following HBsAg loss and be transmitted, but the virological features are not well defined.MethodsHere we investigated 25 Korean patients who lost HBsAg during follow up, either spontaneously or subsequent to therapy.ResultsWhereas subtype adr (genotype C was found in 96% of HBsAg positive patients, 75 % of patients who lost HBsAg spontaneously were seemed to be infected with the ayw subtype with sequence similar to genotype D. Mutations in the major hydrophilic region (MHR of HBsAg were found in 7 patients who lost HBsAg spontaneously. The mutations include T123S, M125I/N, C139R, D144E, V177A, L192F, and W196L, some of which have not been reported before. Functional analysis via transfection experiments indicate that the C139R and D144E mutations drastically reduced HBsAg antigenicity, while the Y225del mutation found in one interferon-treated patient impaired HBsAg secretion.ConclusionsLack of detectable HBsAg in patient serum could be explained by low level of ccc DNA in liver tissue, low antigenicity of the surface protein, or its secretion defect.

  19. Viral hepatitis and rapid diagnostic test based screening for HBsAg in HIV-infected patients in rural Tanzania.

    Directory of Open Access Journals (Sweden)

    Fabian C Franzeck

    Full Text Available BACKGROUND: Co-infection with hepatitis B virus (HBV is highly prevalent in people living with HIV in Sub-Saharan Africa. Screening for HBV surface antigen (HBsAg before initiation of combination antiretroviral therapy (cART is recommended. However, it is not part of diagnostic routines in HIV programs in many resource-limited countries although patients could benefit from optimized antiretroviral therapy covering both infections. Screening could be facilitated by rapid diagnostic tests for HBsAg. Operating experience with these point of care devices in HIV-positive patients in Sub-Saharan Africa is largely lacking. We determined the prevalence of HBV and Hepatitis C virus (HCV infection as well as the diagnostic accuracy of the rapid test device Determine HBsAg in an HIV cohort in rural Tanzania. METHODS: Prospectively collected blood samples from adult, HIV-1 positive and antiretroviral treatment-naïve patients in the Kilombero and Ulanga antiretroviral cohort (KIULARCO in rural Tanzania were analyzed at the point of care with Determine HBsAg, a reference HBsAg EIA and an anti-HCV EIA. RESULTS: Samples of 272 patients were included. Median age was 38 years (interquartile range [IQR] 32-47, 169/272 (63% subjects were females and median CD4+ count was 250 cells/µL (IQR 97-439. HBsAg was detected in 25/272 (9.2%, 95% confidence interval [CI] 6.2-13.0% subjects. Of these, 7/25 (28% were positive for HBeAg. Sensitivity of Determine HBsAg was rated at 96% (95% CI 82.8-99.6% and specificity at 100% (95% CI, 98.9-100%. Antibodies to HCV (anti-HCV were found in 10/272 (3.7%, 95% CI 2.0-6.4% of patients. CONCLUSION: This study reports a high prevalence of HBV in HIV-positive patients in a rural Tanzanian setting. The rapid diagnostic test Determine HBsAg is an accurate assay for screening for HBsAg in HIV-1 infected patients at the point of care and may further help to guide cART in Sub-Saharan Africa.

  20. The impact of maternal HBsAg carrier status on pregnancy outcomes: a case-control study.

    Science.gov (United States)

    Tse, Ka Yu; Ho, Lai Fong; Lao, Terence

    2005-11-01

    To examine the impact of maternal HBsAg carrier status on pregnancy outcomes. Two hundred and fifty-three carriers of hepatitis B surface antigen (HBsAg) with singleton pregnancy, were retrospectively compared with 253 controls matched for age and parity and year of delivery. On univariable analysis, HBsAg carriers had higher incidences of threatened preterm labour at <37 weeks (11.9% vs. 6.3%, P=0.030), preterm birth at <34 weeks (4.7% vs. 1.2%, P=0.033), gestational diabetes mellitus (19.0% vs. 11.1%, P=0.012) and antepartum haemorrhage (11.5% vs. 5.5%, P=0.026). Their infants had lower Apgar scores at the 1st (8.47+/-1.67 vs. 8.87+/-1.07, P=0.001) and 5th minute (9.56+/-1.29 vs. 9.80+/-0.54, P=0.007), and increased incidence of intraventricular haemorrhage (4.7% vs. 0.8%, P=0.007). On multivariable analysis, the association between HBsAg carrier state with antepartum haemorrhage, gestational diabetes mellitus and threatened preterm labour were confirmed. HBsAg carriers have increased risk of gestational diabetes mellitus, antepartum haemorrhage, and threatened preterm labour. This may be related to the chronic inflammatory state in these subjects. The role of chronic HBV infection in pregnancy complications has to be further elucidated.

  1. Comparison of Abbott and Da-an real-time PCR for quantitating serum HBV DNA.

    Science.gov (United States)

    Qiu, Ning; Li, Rui; Yu, Jian-Guo; Yang, Wen; Zhang, Wei; An, Yong; Li, Tong; Liu, Xue-En; Zhuang, Hui

    2014-09-07

    To compare the performance of the Da-an real-time hepatitis B virus (HBV) DNA assay and Abbott RealTime HBV assay. HBV DNA standards as well as a total of 180 clinical serum samples from patients with chronic hepatitis B were measured using the Abbott and Da-an real-time polymerase chain reaction (PCR) assays. Correlation and Bland-Altman plot analysis was used to compare the performance of the Abbott and Da-an assays. The HBV DNA levels were logarithmically transformed for analysis. All statistical analyses were performed using SPSS for Windows version 18.0. The correlation between the two assays was analyzed by Pearson's correlation and linear regression. The Bland-Altman plots were used for the analysis of agreement between the two assays. A P value of Da-an assay were significantly correlated with the expected values of HBV DNA standards (r = 0.999, for Abbott; r = 0.987, for Da-an, P Da-an assay. Moreover, HBV DNA levels measured by the Abbott assay were significantly higher than those of the Da-an assay (6.23 ± 1.76 log IU/mL vs 5.46 ± 1.55 log IU/mL, P Da-an assay presented lower sensitivity and a narrower linear range as compared to the Abbott assay, suggesting the need to be improved.

  2. Evaluation of HBsAg and anti-HBc assays in saliva and dried blood spot samples according HIV status.

    Science.gov (United States)

    Flores, Geane Lopes; Cruz, Helena Medina; Potsch, Denise Vigo; May, Silvia Beatriz; Brandão-Mello, Carlos Eduardo; Pires, Marcia Maria Amendola; Pilotto, Jose Henrique; Lewis-Ximenez, Lia Laura; Lampe, Elisabeth; Villar, Livia Melo

    2017-09-01

    Influence of HIV status in HBV markers detection in saliva and dried blood spots (DBS) was not well established. This study aims to evaluate the performance of optimized commercial immunoassay for identifying HBsAg and anti-HBc in saliva and DBS according HIV status. A sum of 535 individuals grouped as HIV + , HBV + , HIV/HBV + and HIV/HBV- were recruited where 347 and 188 were included for HBsAg and anti-HBc evaluation, respectively. Serum, DBS collected in Whatman 903 paper and saliva obtained using salivette device were analyzed using EIA. Increased sample volume and ROC curve analysis for cut off determination were used for DBS and saliva testing. HBsAg detection in saliva and DBS exhibited sensitivities of 80.9% and 85.6% and specificities of 86.8% and 96.3%. Sensitivity of anti-HBc in saliva and DBS were 82.4% and 76.9% and specificities in saliva and DBS were 96.9% and 91.7%. Low sensitivities were observed for HBsAg (62%) and anti-HBc (47%) detection in saliva of HIV/HBV+ individuals. OD values were also lower for HBsAg detection in DBS and saliva of HIV/HBV+ individuals compared to their serum samples. Statistical significance was found for sensitivities in HBsAg detection between saliva and DBS demonstrating high sensitivity for DBS specimens. In conclusion, HIV status or antiretroviral treatment appears to interfere in the performance of HBsAg and anti-HBc detection in DBS and saliva samples using the adapted commercial EIA. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. The Ausab test - a radioimmunoassay in the solid phase for the detection of antibodies against HBsAg

    International Nuclear Information System (INIS)

    Lange, W.; Koehler, H.; Apodaca, J.

    1974-01-01

    The suitability of a newly developed RIA (Ausab test, Abbott Laboratories) for the detection of antibodies against the Hepatitis B (surface) antigen (HBsAg) has been tested on 1,968 sera of blood donors. Reproducibility test and specificity test were included. During the examination the technique of the Ausab test was changed from the original one-step to the two-step procedure. With the one-step technique 431 of 1,968 sera (21.9%) showed positive reactions. During the test problems concerning the differentiation between positive and negative results were encountered due to high unspecific binding of radioactivity. Positive sera were reexamined employing the two-step technique and only 77.4% of the previously positive reactions could be reproduced. 50 sera that were negative in the one-step test remained negative in the two-step test. Difficulties concerning nonspecific binding of radioactivity as observed with the one-step technique were not ecountered with the two-step procedure. On 92 of the confirmed positive sera a specificity test was run and 90 (97.8%) proved to be specific. A calculated 16.5% of the blood donors in Berlin have to be considered as antibody carriers. Only 6 of the Ausab positive sera were found to give positive reactions in CEP. 3 sera that were initially positive in CEP could neither be confirmed in a repeated CEP nor in the Ausab test. (orig.) [de

  4. Retroreflective Phase Retardation Prisms.

    Science.gov (United States)

    1981-06-01

    resonant cavity of a 1.064 Mm laser. This report shows that it is possible to coat the reflecting surfaces of a porro prism so that incident plane...with controlled phase retardation can be made by coating each reflecting surface of a porro prism with a single dielectric film. The amount of phase...of angle of incidence (n, < n2) S. Phase change on reflection as a function of angle of incidence (n" n ) [RL-0202-’R 6. Porro prism 7. Phase change

  5. HBsAg seroprevalence in students for college entrance examination from 2006 to 2014 in Qidong of Jiangsu Province

    Directory of Open Access Journals (Sweden)

    NI Zhengping

    2015-10-01

    Full Text Available ObjectiveTo investigate the HBsAg seroprevalence in the young generation in Qidong of Jiangsu Province, China. MethodsA total of 15 534 students for college entrance examination from 2006 to 2014 were randomly selected from three secondary schools in Qidong as student group. Some of them had hepatitis B vaccination at birth. A total of 1208 adults who had their routine checkups in our hospital from 2007 to 2013 were selected as adult group. It was confirmed that all of them did not have hepatitis B vaccination at birth. Serum HBsAg levels of the two groups were measured using enzyme-linked immunosorbent assay and the seroprevalence was analyzed. Comparison of data between the two groups was made by chi-square test. Results In the 9 years from 2007 to 2013, the seroprevalence rates of HBsAg in the student group were 4.2%(75/1794, 4.3%(77/1797, 4.4%(82/1858, 4.3%(82/1903, 3.4%(56/1627, 2.6%(46/1768, 1.6%(29/1778, 1.6%(27/1642, and 1.8%(24/1367, respectively. The mean HBsAg seroprevalence of the student group was 3.2%(498/15534, significantly lower compared with 7.1% (86/1208 of the adult group (χ2= 59.986, P<0.001. In both of the student group and the adult group, the males had a significantly higher HBsAg seroprevalence than the females (χ2=10.521, P=0.001; χ2=8.452, P=0.004 and the values were 3.7%(266/7236 vs 2.8%(229/8298 and 8.8%(66/750 vs 4.4%(20/458, respectively. Among male subjects, the HBsAg seroprevalence of the adult group was 2.4 times that of the student group; among female subjects, the HBsAg seroprevalence of the adult group was 1.6 times that of the student group. ConclusionIn the recent 9 years from 2006 to 2014, the HBsAg seroprevalence in students for college entrance examination declined continuously. The goal set by the World Health Organization Western Pacific Region in 2010 had been achieved ahead of the schedule that the HBsAg seroprevalence should be controlled below 2% in children aged less than 5.

  6. Frequency of anti-HCV, Hbsag and related risk factors in pregnant women at Nishtar Hospital, Multan

    International Nuclear Information System (INIS)

    Taseer, I.H.; Ishaq, F.; Hussain, L.; Safdar, S.; Mirbahar, A.M.; Faiz, S.A.

    2010-01-01

    Background: Viral hepatitis is a global issue. Among the hepatitis viruses hepatitis B and C are important in South Asia including Pakistan. There are various modes of transmission of these viruses. Vertical transmission is also gaining importance. Antepartum screening for HBV and HCV would help the infected women for appropriate antiviral therapy at appropriate time as well as for taking proper care of the newborns. The present study was designed to see the frequency of HBsAg and anti-HCV in pregnant women at Nishtar Hospital, Multan. Methods: This was a cross-sectional study carried out using non-probability purposive sampling technique. The period of the study was from June 2006 to August 2007. Five hundred (500) pregnant women attending outpatient department of Gynaecology and Obstetrics were included. Informed consent was taken. A specially designed proforma was filled in. Anti-HCV and HBsAg were tested by device method. Data were analyzed on SPSS-11. Results: Out of 500 pregnant women 35 (7.00%) were found to be anti-HCV positive and 23 (4.60%) were positive for HBsAg. Mean age was 26.7+-4.8 years. Majority of the patients 263 (52.60%) were in the age group 26-35 years. 138 (27.60%) women were nulliparous and 282 (56.40%) were para 1-4 and anti-HCV and HBsAg were common in this parity group. Only 80 (16.00%) women were para 5 or more. All anti-HCV and HBsAg positive women were house-wives. Most of them were belonging to rural areas having poor socio-economic status. Among 35 anti-HCV positive women, 20 (57.14%) had history of previous surgery, while 13 (37.14%) had history of multiple injections, 5 (14.28%) received blood transfusion, 4 (11.42%) had ear/nose piercing while tattooing was seen in only 2 (5.71%). Among 23 HBsAg positive women, 10 (43.47%) had history of previous surgery. History of multiple injections was present in 6 (26.08%) patients, 4 (17.39%) patients had history of blood transfusion, tattooing, ear/nose piercing, history of dental

  7. An investigation of clinical features of HBsAg and anti-HBs positive patients with chronic hepatitis B

    Directory of Open Access Journals (Sweden)

    SONG Jinyun

    2016-11-01

    Full Text Available ObjectiveTo investigate the phenomenon of coexistence of HBsAg and anti-HBs and its clinical features, as well as related causes. MethodsA total of 2260 persons who underwent physical examination in The Second Affiliated Hospital of Southeast University from February 2011 to February 2014 were enrolled, among whom 830 were diagnosed with chronic hepatitis B. Chemiluminescence microparticle immunoassay was used to screen out 188 patients with coexistence of HBsAg and anti-HBs, and these patients were divided into HBeAg positive group (101 patients and HBeAg negative group (87 patients. Another 200 patients with positive HBsAg and negative anti-HBs were enrolled as controls, among whom 80 were in the HBeAg-positive group and 120 were in the HBeAg-negative group. HBV serological markers, liver function, and viral load were measured and analyzed with reference to clinical manifestations. The chi-square test was used for comparison of categorical data between groups. ResultsThere were five patterns of HBV serological markers in patients with positive HBsAg and anti-HBs, among which positive HBsAg, anti-HBs, HBeAg, and anti-HBc and negative anti-HBe were the most common and accounted for 47.9% (90/188. The overall abnormal rate of liver function parameters was 69.1% (130/188, and the positive rate of HBV DNA was 56.9% (107/188. The two groups with positive HBeAg had a high level of HBV DNA replication, and there was no significant difference in the positive rate of HBV DNA between positive HBsAg and anti-HBs group and control group (P>0.05. In the groups with negative HBeAg, there was a significant difference in the proportion of patients with HBV DNA quantitation of >1×10^5 IU/ml between positive HBsAg and anti-HBs group and control group (P<0.05. The sequencing of the S region of HBV showed that among the 80 patients with positive HBsAg and anti-HBs, 27 had variations in this region, and the mutation rate reached 33.7%. The major variation

  8. Species specificity for HBsAg binding protein endonexin II

    NARCIS (Netherlands)

    deBruin, WCC; Leenders, WPJ; Moshage, H; vanHaelst, UJGM

    Background/Aims: Hepatitis B virus displays a distinct species and tissue tropism, Previously we have demonstrated that a human liver plasma membrane protein,vith a molecular weight of approximately 34 kiloDalton specifically binds to HBsAg. This protein was identified as endonexin II, a Ca2+

  9. Clinical Characteristics and Correlation Analysis of Subjects with Chronic Hepatitis B Virus (HBV) Infection and Sustained Low Levels of Hepatitis B Surface Antigen (HBsAg)

    Science.gov (United States)

    Cheng, Jun; Dai, Yuzhu; Yan, Li; Zhou, Huajun; Xu, Xujian

    2018-01-01

    Background The aim of this study was to investigate the clinical characteristics of individuals with chronic hepatitis B virus (HBV) infection with persistent low levels of hepatitis B surface antigen (HBsAg) and to undertake a correlation analysis of the clinical characteristics. Material/Methods The study included 1,204 subjects with chronic HBV infection. Serum HBsAg, HBV envelope antigen (HBeAg), and HBV core antigen (HBcAg) levels were measured using the chemiluminescent microparticle immunoassay (CMIA) and the neutralization test. HBV DNA was measured using real-time fluorescence quantitative polymerase chain reaction (RT-FQ-PCR). Results There were 1,023 subjects in the high-level HBsAg group (HBsAg level ≥10 IU/mL) and 181 subjects in the low-level HBsAg group (HBsAg level HBV-M2), and the asymptomatic carrier (ASC) status was 98.34%. The low-level HBsAg group had a lower HBV DNA-positive rate compared with the high-level HBsAg group (40.33% vs. 75.07%), with a normal distribution across all age groups (P>0.05). The low-level HBsAg group included an older age group. A low-level of HBsAg was positively correlated with a low level of replication of HBV DNA (r=0.452). Conclusions The findings of this study showed that individuals with chronic HBV infection and sustained low-levels of HBsAg were an older population and had a lower level of replicating HBV DNA when compared with individuals with high levels of HBsAg, and the majority (93.7%) were also HBsAg and HBeAg and HBcAg-positive. PMID:29593208

  10. Value of HBsAg level in dynamic monitoring of disease progression in patients with chronic HBV infection

    Directory of Open Access Journals (Sweden)

    BAO Teng

    2017-08-01

    Full Text Available ObjectiveTo investigate the clinical value of HBsAg level in dynamic monitoring of disease progression in patients with chronic HBV infection. MethodsA retrospective analysis was performed for the clinical data of 1107 patients with different clinical stages of chronic HBV infection who had not received antiviral therapy at the time of hospitalization in The Second Affiliated Hospital of Anhui Medical University from May 2011 to December 2015, and according to the disease status, they were divided into HBeAg-positive chronic hepatitis B (CHB group, HBeAg-negative CHB group, compensated liver cirrhosis group (LC-C group, decompensated liver cirrhosis group (LC-D group, and primary liver cancer (PLC group. These groups were compared in terms of HBsAg expression and the association between HBsAg and clinical features. An analysis of variance was used for comparison of continuous data between multiple groups, and the least significant difference t-test was used for further comparison between any two groups; the t-test was used for comparison of continuous data between two groups. The chi-square test was used for comparison of categorical data between these groups. Pearson correlation analysis was also performed. ResultsThere was a significant difference in serum HBsAg level between the HBeAg-positive CHB group, HBeAg-negative CHB group, LC-C group, LC-D group, and PLC group (F=100.45, P<0.001. The HBeAg-positive CHB group had significantly higher levels of HBsAg and HBV DNA than the HBeAg-negative CHB group (t= 16.67 an 16.22, both P<0.001. There were significant differences in HBsAg and HBV DNA levels between the HBeAg-positive CHB group, LC-C group, LC-D group, and PLC group (F= 42.92 and 27.38, both P<0.001, as well as between the HBeAg-negative CHB group, LC-C group, LC-D group, and PLC group (F=6.04 and 4.10, both P<0.05. HBV DNA level was significantly different across patients with different HBsAg levels (<1000 IU/ml, 1000-20 000 IU

  11. Results of HBsAg examination with immunoelectrophoresis and radioimmunoassay in VPR, Laotian PDR and Cuban R

    Energy Technology Data Exchange (ETDEWEB)

    Michal, L; Szilagyiova, M; Zahradny, V; Holan, J; Krajnak, V [Komenskeho Univ., Martin (Czechoslovakia). Lekarska Fakulta; Padurova, J [Okresna Hygienicka Stanica, Zilina (Czechoslovakia)

    1984-06-21

    The results are compared of examining 112 Vietnamese, 30 Laotian and 50 Cuban citizens for HBsAg using IEP and RIA methods. Of the examined persons with no liver disorders HBsAg was found in 23 (31.5%) of the Vietnamese and 1 (2.5%) of the Cubans using the RIA method and only in 4 (5.5%) of the Vietnamese using the IEP method. Of the examined persons with liver disorders RIA found HBsAg in 12 (30.8%) of the Vietnamese, 5 (71.4%) of the Laotians and 2 (20.0%) of the Cubans while with IEP only in 3 (7.7%) Vietnamese 2 (28.6%) Laotians and 1 (10.0%) of the Cubans examined.

  12. Results of HBsAg examination with immunoelectrophoresis a radioimmunoassay in VPR, Laotian PDR and Cuban R

    International Nuclear Information System (INIS)

    Michal, L.; Szilagyiova, M.; Zahradny, V.; Holan, J.; Krajnak, V.

    1984-01-01

    The results are compared of examining 112 Vietnamese, 30 Laotian and 50 Cuban citizens for HBsAg using IEP and RIA methods. Of the examined persons with no liver disorders HBsAg was found in 23 (31.5%) of the Vietnamese and 1 (2.5%) of the Cubans using the RIA method and only in 4 (5.5%) of the Vietnamese using the IEP method. Of the examined persons with liver disorders RIA found HBsAg in 12 (30.8%) of the Vietnamese, 5 (71.4%) of the Laotians and 2 (20.0%) of the Cubans while with IEP only in 3 (7.7%) Vietnamese 2 (28.6%) Laotians and 1 (10.0%) of the Cubans examined. (author)

  13. 21 CFR 886.1650 - Ophthalmic bar prism.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic bar prism. 886.1650 Section 886.1650...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1650 Ophthalmic bar prism. (a) Identification. An ophthalmic bar prism is a device that is a bar composed of fused prisms of gradually increasing...

  14. 78 FR 23220 - Foreign-Trade Zone 22-Chicago, Illinois, Authorization of Production Activity, Abbott...

    Science.gov (United States)

    2013-04-18

    ... DEPARTMENT OF COMMERCE Foreign-Trade Zones Board [B-91-2012] Foreign-Trade Zone 22--Chicago, Illinois, Authorization of Production Activity, Abbott Laboratories, Inc., AbbVie, Inc. (Pharmaceutical Production), North Chicago, Illinois, Area On December 14, 2012, Abbott Laboratories, Inc., and AbbVie, Inc...

  15. 21 CFR 886.1660 - Gonioscopic prism.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1660 Gonioscopic prism. (a) Identification. A gonioscopic prism is a device that is a prism intended to be placed on the eye to study the anterior chamber. The device may have angled mirrors to facilitate visualization of anatomical features. (b...

  16. [Predictive study of HBsAg in different stages of neonatal venous blood on failure of blocking HBV mother to infant transmission].

    Science.gov (United States)

    Yi, Wei; Li, Ming-Hui; Hu, Yu-Hong; Liu, Feng; Zhang, Yang-Li; Liu, Xue-Jing; Hao, Hong-Xiao; Song, Shu-Jing; Liu, Ying; Li, Xing-Hong; Sun, Ji-Yun; Liu, Min; Cheng, Jun; Xie, Yao

    2011-10-01

    In this study, we discuss the predictive value of different content of HBsAg in different stages of neotal venous blood on failure of blocking mother to infant transmission of HBV. 150 infants born of chronically HBV infected mothers who were positive of both HBsAg and HBeAg and who also had a HBV DNA virus load above 10(5) copies/ml were enrolled. These infants were given hepatitis B virus immune globin (HBIG) 200 IU immediately after birth and were given hepatitis B vaccine 10 or 20 microg at brith, 1 month and 6 months after birth. HBV serological index of these infants were test at birth, 1 month and 7 months after birth respectively. Different content of HBsAg in different stages of neonatal venus blood were analyzed to predict the failure of blocking mother to infant transmission of HBV. 11 infants failed in blocking of HBV mother to infant transmission. The positive rate of HBsAg at birth, 1 month and 7 months after birth were 41.26%, 10.49% and 7.69% respectively, and were 97.90%, 65.73% and 13.29% of HBeAg. The positive predictive value of HBsAg > or = 0.05 and HBsAg > or = 1 IU/ml at birth were 18.64% and 70% respectively, and were 73.33% and 100% one month after birth. Infants with HBsAg > or = 1 IU/ml at birth should be suspicious of failure on blocking HBV mother-to-infant transmission and it should be more credible if the infant has HBsAg > or = 1 IU/ml one month after birth. How to improve the blocking rate of neonates who were positive of HBsAg at birth and one month after birth should be the focus of our future research.

  17. Maude Abbott and the Origin and Mysterious Disappearance of the Canadian Medical War Museum.

    Science.gov (United States)

    Wright, James R; Alberti, Samuel J M M; Lyons, Christopher; Fraser, Richard S

    2018-05-07

    - In the early 1900s, it was common practice to retain, prepare, and display instructive pathologic specimens to teach pathology to medical trainees and practitioners; these collections were called medical museums. Maude Abbott established her reputation by developing expertise in all aspects of medical museum work. She was a founder of the International Association of Medical Museums (later renamed the International Academy of Pathology) and became an internationally renowned expert on congenital heart disease. Her involvement in the Canadian Medical War Museum (CMWM) is less well known. - To explore Abbott's role in the development of the CMWM during and after World War I and to trace its history. - Available primary and secondary historical sources were reviewed. - Instructive pathologic specimens derived from Canadian soldiers dying during World War I were shipped to the Royal College of Surgeons in London, which served as a clearinghouse for museum specimens from Dominion forces. The Canadian specimens were repatriated to Canada, prepared by Abbott, and displayed at several medical meetings. Abbott, because she was a woman, could not enlist and so she reported to a series of enlisted physicians with no expertise in museology. Plans for a permanent CMWM building in Ottawa eventually failed and Abbott maintained the collection at McGill (Montreal, Quebec, Canada) until her death in 1940. We trace the CMWM after her death. - Sadly, after Abbott had meticulously prepared these precious teaching specimens so that their previous owners' ultimate sacrifice would continue to help their military brethren, the relics were bureaucratically lost.

  18. The PRISM project

    Science.gov (United States)

    Guilyardi, E.

    2003-04-01

    The European Union's PRISM infrastructure project (PRogram for Integrated earth System Modelling) aims at designing a flexible environment to easily assemble and run Earth System Models (http://prism.enes.org). Europe's widely distributed modelling expertise is both a strength and a challenge. Recognizing this, the PRISM project aims at developing an efficient shared modelling software infrastructure for climate scientists, providing them with an opportunity for greater focus on scientific issues, including the necessary scientific diversity (models and approaches). The proposed PRISM system includes 1) the use - or definition - and promotion of scientific and technical standards to increase component modularity, 2) an end-to-end software environment (coupler, user interface, diagnostics) to launch, monitor and analyze complex Earth System Models built around the existing and future community models, 3) testing and quality standards to ensure HPC performance on a variety of platforms and 4) community wide inputs and requirements capture in all stages of system specifications and design through user/developers meetings, workshops and thematic schools. This science driven project, led by 22 institutes* and started December 1st 2001, benefits from a unique gathering of scientific and technical expertise. More than 30 models (both global and regional) have expressed interest to be part of the PRISM system and 6 types of components have been identified: atmosphere, atmosphere chemistry, land surface, ocean, sea ice and ocean biochemistry. Progress and overall architecture design will be presented. * MPI-Met (Coordinator), KNMI (co-coordinator), MPI-M&D, Met Office, University of Reading, IPSL, Meteo-France, CERFACS, DMI, SMHI, NERSC, ETH Zurich, INGV, MPI-BGC, PIK, ECMWF, UCL-ASTR, NEC, FECIT, SGI, SUN, CCRLE

  19. Transient performance of S-prism

    International Nuclear Information System (INIS)

    Dubberley, A.E.; Boardman, C.E.; Gamble, R.E.; Hiu, M.M.; Lipps, A.J.; Wu, T.

    2001-01-01

    S-PRISM is an advanced Fast Reactor plant design that utilizes compact modular pool-type reactors sized to enable factory fabrication and an affordable prototype test of a single Nuclear Steam Supply System (NSSS) for design certification at minimum cost and risk. Based on the success of the previous DOE sponsored Advanced Liquid Metal Reactor (ALMR) program GE has continued to develop and assess the technical viability and economic potential of an up-rated plant called SuperPRISM (S-PRISM). This paper presents the results of transient analyses performed to assess the ability of S-PRISM to accommodate severe accident initiator events. A unique safety capability of S-PRISM is accommodation of the ''higher probability'' accident initiators that led to core melt accidents in prior large LMRs. These events, the Anticipated Transients Without Scram (ATWS) events, are thus the focus of passive safety confirmation analyses. The events included in this assessment are: Unprotected Loss of Flow, Unprotected Loss of Heat Sink, Unprotected Loss of Flow and Heat sink, Unprotected Transient Overpower and Unprotected Safe Shutdown Earthquake. (author)

  20. Prevalence of hepatitis b virus surface antigens (HBsag) and ...

    African Journals Online (AJOL)

    The prevalences of hepatitis B virus surface antigen (HBsAg) and hepatitis C virus (HCV) antibodies were determined in 560 blood donors sera using ELISA kits (DIALAB., Austria). Forty eight (8.57%) of these were positive for hepatitis B virus infection, while 33(5.89%) were positive to hepatitis C virus antibodies. The sex ...

  1. Avoidance of generic competition by Abbott Laboratories' fenofibrate franchise.

    Science.gov (United States)

    Downing, Nicholas S; Ross, Joseph S; Jackevicius, Cynthia A; Krumholz, Harlan M

    2012-05-14

    The ongoing debate concerning the efficacy of fenofibrate has overshadowed an important aspect of the drug's history: Abbott Laboratories, the maker of branded fenofibrate, has produced several bioequivalent reformulations that dominate the market, although generic fenofibrate has been available for almost a decade. This continued use of branded formulations, which cost twice as much as generic versions of fenofibrate, imposes an annual cost of approximately $700 million on the US health care system. Abbott Laboratories maintained its dominance of the fenofibrate market in part through a complex switching strategy involving the sequential launch of branded reformulations that had not been shown to be superior to the first-generation product and patent litigation that delayed the approval of generic formulations. The small differences in dose of the newer branded formulations prevented their substitution with generics of older-generation products. As soon as direct generic competition seemed likely at the new dose level, where substitution would be allowed, Abbott would launch another reformulation, and the cycle would repeat. Based on the fenofibrate example, our objective is to describe how current policy can allow pharmaceutical companies to maintain market share using reformulations of branded medications, without demonstrating the superiority of next-generation products.

  2. Serologic tracers (HBsAg and HBsAc) of hepatitis B virus in expectant mothers of the Perinatal Maternal Institute; Marcadores serologicos (HBsAg y HBsAc) del virus de la hepatitis B en mujeres gestantes del Instituto Materno Perinatal

    Energy Technology Data Exchange (ETDEWEB)

    Garcia G, B M

    1997-07-01

    A study on hepatitis B tracers, (HBsAg and HBsAc), was conducted in women with different months of pregnancy at the Perinatal Maternal Institute in Lima, Peru. A total of 1010 mothers were studied during the period of January to October 1996, establishing by radioimmunoassay (RIA) whether they were positive or not. The results showed a prevalence rate of 1,6 for HBsAc and 1,3 for HBsAg for every 100,000 inhabitants. The incidence rate was 0,332 for HBsAc and 0,07 for HBsAg for every 100,000 inhabitants. This means that 21 expectant mothers are HBsAc positive and 5 are HBsAg positive. According to the investigations, there were different ways of transmission; promiscuity must be highlighted, as well as age -most of the mothers who were positive were between 20 and 25 years old- and origin. Most of them were immigrants from different places and live in shantytowns, which indicates that most of them have limited economic resources and have not received any orientation on family planning.

  3. Prisms to Shift Pain Away: Pathophysiological and Therapeutic Exploration of CRPS with Prism Adaptation.

    Science.gov (United States)

    Christophe, Laure; Chabanat, Eric; Delporte, Ludovic; Revol, Patrice; Volckmann, Pierre; Jacquin-Courtois, Sophie; Rossetti, Yves

    Complex Regional Pain Syndrome (CRPS) is an invalidating chronic condition subsequent to peripheral lesions. There is growing consensus for a central contribution to CRPS. However, the nature of this central body representation disorder is increasingly debated. Although it has been repeatedly argued that CRPS results in motor neglect of the affected side, visual egocentric reference frame was found to be deviated toward the pain, that is, neglect of the healthy side. Accordingly, prism adaptation has been successfully used to normalize this deviation. This study aimed at clarifying whether 7 CRPS patients exhibited neglect as well as exploring the pathophysiological mechanisms of this manifestation and of the therapeutic effects of prism adaptation. Pain and quality of life, egocentric reference frames (visual and proprioceptive straight-ahead), and neglect tests (line bisection, kinematic analyses of motor neglect and motor extinction) were repeatedly assessed prior to, during, and following a one-week intense prism adaptation intervention. First, our results provide no support for visual and motor neglect in CRPS. Second, reference frames for body representations were not systematically deviated. Third, intensive prism adaptation intervention durably ameliorated pain and quality of life. As for spatial neglect, understanding the therapeutic effects of prism adaptation deserves further investigations.

  4. Integrating Students of Limited English Proficiency into Standards-Based Reform in the Abbott Districts. Abbott Implementation Resource Guide

    Science.gov (United States)

    Lucas, Tamara; Villegas, Ana Maria

    2004-01-01

    In 1999-2000, over one-third of all students in the 30 Abbott districts spoke a native language other than English, and more than one-tenth were considered limited English proficient (LEP). The proportions of LEP students varied considerably across the districts, but they comprised between 5% and 29% of total enrollments in 18 of the districts.…

  5. The PRISM3D paleoenvironmental reconstruction

    Science.gov (United States)

    Dowsett, H.; Robinson, M.; Haywood, A.M.; Salzmann, U.; Hill, Daniel; Sohl, L.E.; Chandler, M.; Williams, Mark; Foley, K.; Stoll, D.K.

    2010-01-01

    The Pliocene Research, Interpretation and Synoptic Mapping (PRISM) paleoenvironmental reconstruction is an internally consistent and comprehensive global synthesis of a past interval of relatively warm and stable climate. It is regularly used in model studies that aim to better understand Pliocene climate, to improve model performance in future climate scenarios, and to distinguish model-dependent climate effects. The PRISM reconstruction is constantly evolving in order to incorporate additional geographic sites and environmental parameters, and is continuously refined by independent research findings. The new PRISM three dimensional (3D) reconstruction differs from previous PRISM reconstructions in that it includes a subsurface ocean temperature reconstruction, integrates geochemical sea surface temperature proxies to supplement the faunal-based temperature estimates, and uses numerical models for the first time to augment fossil data. Here we describe the components of PRISM3D and describe new findings specific to the new reconstruction. Highlights of the new PRISM3D reconstruction include removal of Hudson Bay and the Great Lakes and creation of open waterways in locations where the current bedrock elevation is less than 25m above modern sea level, due to the removal of the West Antarctic Ice Sheet and the reduction of the East Antarctic Ice Sheet. The mid-Piacenzian oceans were characterized by a reduced east-west temperature gradient in the equatorial Pacific, but PRISM3D data do not imply permanent El Niño conditions. The reduced equator-to-pole temperature gradient that characterized previous PRISM reconstructions is supported by significant displacement of vegetation belts toward the poles, is extended into the Arctic Ocean, and is confirmed by multiple proxies in PRISM3D. Arctic warmth coupled with increased dryness suggests the formation of warm and salty paleo North Atlantic Deep Water (NADW) and a more vigorous thermohaline circulation system that may

  6. Geometric formula for prism deflection

    Indian Academy of Sciences (India)

    , governs deflections produced by prisms of refractive index n. The refractive power, n − 1, of most materials is of the order of unity for visible light, which therefore gets deflected through several degrees by a prism. X-rays and neutrons however ...

  7. Direct detection of Mycobacterium tuberculosis and drug resistance in respiratory specimen using Abbott Realtime MTB detection and RIF/INH resistance assay.

    Science.gov (United States)

    Tam, Kingsley King-Gee; Leung, Kenneth Siu-Sing; To, Sabrina Wai-Chi; Siu, Gilman Kit-Hang; Lau, Terrence Chi-Kong; Shek, Victor Chi-Man; Tse, Cindy Wing-Sze; Wong, Samson Sai-Yin; Ho, Pak-Leung; Yam, Wing-Cheong

    2017-10-01

    Abbott RealTime MTB (Abbott-RT) in conjunction with Abbott RealTime MTB RIF/INH Resistance (Abbott-RIF/INH) is a new, high-throughput automated nucleic acid amplification platform (Abbott-MDR) for detection of Mycobacterium tuberculosis complex (MTBC) and the genotypic markers for rifampicin (RIF) and isoniazid (INH) resistance directly from respiratory specimens. This prospective study evaluated the diagnostic performance of this new platform for MTBC and multidrug-resistant tuberculosis (MDR-TB) using 610 sputum specimens in a tuberculosis high-burden setting. Using conventional culture results and clinical background as reference standards, Abbott-RT exhibited an overall sensitivity and specificity of 95.2% and 99.8%, respectively. Genotypic RIF/INH resistance of 178 "MTB detected" specimens was subsequently analyzed by Abbott-RIF/INH. Compared to phenotypic drug susceptibility test results, Abbott-RIF/INH detected resistance genotypic markers in 84.6% MDR-TB, 80% mono-RIF-resistant and 66.7% mono-INH-resistant specimens. Two of the RIF-resistant specimens carried a novel single, nonsense mutation at rpoB Q513 and in silico simulation demonstrated that the truncated RpoB protein failed to bind with other subunits for transcription. Overall, Abbott-MDR platform provided high throughput and reliable diagnosis of MDR-TB within a TB high-burden region. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. PRISM: Enmeshment of illness and self-schema.

    Science.gov (United States)

    Denton, Fiona; Sharpe, Louise; Schrieber, Leslie

    2004-01-01

    The Pictorial Representation of Illness and Self Measure (PRISM) is a recently developed tool purported to assess burden of suffering due to illness. The nature of the PRISM task suggests a conceptual link to the illness self-schema construct hypothesised to be present in some individuals with chronic illness. This study investigates the relationship between PRISM and schema as measured by cognitive bias. 43 patients with systemic lupus erythematosus (SLE) completed an information-processing task involving endorsement of positive and negative illness words as descriptors of themselves, followed by free recall of the words. The outcome measures were endorsement and recall bias for negative illness words. Patients also completed the PRISM task and were assessed on other physical and psychological variables. PRISM did not correlate significantly with age, depression, functional impairment or disease activity. In a multiple regression analysis, only recall bias made an independent contribution to PRISM. Illness self-schema appears to play a significant role in determining the way in which SLE patients complete the PRISM task. This is discussed in light of a schema enmeshment model recently proposed in the cognitive bias literature. Copyright 2004 S. Karger AG, Basel

  9. Comparison of Abbott RealTime High-Risk HPV and Hybrid Capture 2 Assays for Detection of HPV Infection.

    Science.gov (United States)

    Ko, Kiwoong; Yu, Shinae; Lee, Eun Hee; Park, Hyosoon; Woo, Hee-Yeon; Kwon, Min-Jung

    2016-09-01

    Various assays for detecting high-risk human papillomavirus (HR HPV) have been introduced recently, including the Abbott RealTime High-Risk HPV assay. We sought to compare the performance of Abbott PCR to Hybrid Capture 2 for the detection of HR HPV. A total of 941 cervical swab specimens were obtained. We submitted all specimens for HR HPV detection with HC2 and Abbott PCR, and then additionally analyzed discordant and concordant positive results using restriction fragment mass polymorphism (RFMP) genotyping analysis. HC2 detected one of 13 HR HPV types in 12.3% (116/941) of cases, while Abbott PCR detected one of 14 detectable HR HPV types in 12.9% (121/941) of cases. The overall agreement rate was 97.3% with a kappa coefficient of 0.879. Discordant results between these two assays were observed in 25 cases. HC2 showed a sensitivity of 90.0% and specificity of 95.9%, while Abbott PCR showed a sensitivity of 98.0% and specificity of 96.8% when using RFMP results as the gold standard. For HPV 16/18 detection, Abbott PCR showed 95.8%/88.9% sensitivity and 99.2%/99.8% specificity, respectively. The overall coinfection rate between HPV 16, 18 and non-16/18 was 9.9% (12/121) in Abbott PCR analysis. Considering its high agreement rate with HC2, higher sensitivity/specificity compared to HC2, and ability to differentiate HPV 16/18 from other HPV types, Abbott PCR could be a reliable laboratory testing method for the screening of HPV infections. © 2016 by the Association of Clinical Scientists, Inc.

  10. Hepatitis B surface antigen (HBsAg) expression in plant cell culture: Kinetics of antigen accumulation in batch culture and its intracellular form.

    Science.gov (United States)

    Smith, Mark L; Mason, Hugh S; Shuler, Michael L

    2002-12-30

    The production of edible vaccines in transgenic plants and plant cell culture may be improved through a better understanding of antigen processing and assembly. The hepatitis B surface antigen (HBsAg) was chosen for study because it undergoes substantial and complex post-translational modifications, which are necessary for its immunogenicity. This antigen was expressed in soybean (Glycine max L. Merr. cv Williams 82) and tobacco NT1 (Nicotiana tabacum L.) cell suspension cultures, and HBsAg production in batch culture was characterized. The plant-derived antigen consisted predominantly of disulfide cross-linked HBsAg protein (p24(s)) dimers, which were all membrane associated. Similar to yeast, the plant-expressed HBsAg was retained intracellularly. The maximal HBsAg titers were obtained with soybean suspension cultures (20-22 mg/L) with titers in tobacco cultures being approximately 10-fold lower. For soybean cells, electron microscopy and immunolocalization demonstrated that all the HBsAg was localized to the endoplasmic reticulum (ER) and provoked dilation and proliferation of the ER network. Sucrose gradient analysis of crude extracts showed that HBsAg had a complex size distribution uncharacteristic of the antigen's normal structure of uniform 22-nm virus-like particles. The extent of authentic epitope formation was assessed by comparing total p24(s) synthesized to that reactive by polyclonal and monoclonal immunoassays. Depending on culture age, between 40% and 100% of total p24(s) was polyclonal antibody reactive whereas between 6% and 37% was recognized by a commercial monoclonal antibody assay. Possible strategies to increase HBsAg production and improve post-translational processing are discussed. Copyright 2002 Wiley Periodicals, Inc.

  11. Estudo da soroprevalência do AgHBs em gestantes da 15ª Regional de Saúde e da imunoprofilaxia para os recém-nascidos das gestantes AgHBs positivo = Study into the HBsAg seroprevalence in pregnant women from the 15th Health Regional and the immunoprophylaxia on the newborns of these HBsAg-positive women

    Directory of Open Access Journals (Sweden)

    Sonia Kaori Miyamoto

    2008-01-01

    Full Text Available Determinar a prevalência do AgHBs nas gestantes da 15ª Regional de Saúde (15ª R.S. atendidas no Laboratório de Ensino e Pesquisa em Análises Clínicas (Lepac, Universidade Estadual de Maringá, e verificar se foi solicitada a imunoprofilaxia para hepatite B aos recém-natos das gestantes AgHBs positivo, no período de janeiro de 1998 a dezembro de 2002. A pesquisa do AgHBs foi realizada pela técnica imunoenzimática IMxHBsAg e Axsym HBsAg (Laboratório Abbott. As solicitações de imunobiológicos especiais para a imunoprofilaxia da hepatite B ao CRIE foram obtidas na Seção de Epidemiologia da 15ª R.S. Foram analisadas 12.274 gestantes e a prevalência do AgHBs foide 1,0%. Dentre as 125 gestantes AgHBs positivo, foram solicitadas imunoprofilaxia para 32 (25,6% recém-nascidos. Ainda que a prevalência encontrada indique ser esta uma área de baixa endemicidade, os resultados reafirmam a importância da realização do diagnóstico da hepatite B no atendimento pré-natal, para adoção da imunoprofilaxia no recém-nascido.To determine HBsAg prevalence among pregnant women from the 15th Health Regional assisted in the Laboratório de Ensino e Pesquisa em Análises Clínicas (Lepac, Universidade Estadual de Maringá, and verify whether immunoprophylaxis with vaccine and immunoglobulin was requested for the newborns of HBsAg-positive women during the period from January 1998 to December 2002. The research about HBsAg was conducted using the immunoenzymatic IMxHBsAg (Abbot Lab and Axsym HBsAg (Abbot Lab techniques. The requests to the CRIE for specialimmunobiologic agents for Hepatitis B immunoprophylaxis were obtained in the Department of Epidemiology from the 15th Health Regional. The analysis includes 12,274 pregnant women, and the HBsAg prevalence was 1.0%. Among 125 HBsAg positive pregnant women, immunoprophylaxis was requested for 32 (25.6% newborns. Although the prevalence detected demonstrates this to be a low endemic area, the

  12. Performance of the new automated Abbott RealTime MTB assay for rapid detection of Mycobacterium tuberculosis complex in respiratory specimens.

    Science.gov (United States)

    Chen, J H K; She, K K K; Kwong, T-C; Wong, O-Y; Siu, G K H; Leung, C-C; Chang, K-C; Tam, C-M; Ho, P-L; Cheng, V C C; Yuen, K-Y; Yam, W-C

    2015-09-01

    The automated high-throughput Abbott RealTime MTB real-time PCR assay has been recently launched for Mycobacterium tuberculosis complex (MTBC) clinical diagnosis. This study would like to evaluate its performance. We first compared its diagnostic performance with the Roche Cobas TaqMan MTB assay on 214 clinical respiratory specimens. Prospective analysis of a total 520 specimens was then performed to further evaluate the Abbott assay. The Abbott assay showed a lower limit of detection at 22.5 AFB/ml, which was more sensitive than the Cobas assay (167.5 AFB/ml). The two assays demonstrated a significant difference in diagnostic performance (McNemar's test; P = 0.0034), in which the Abbott assay presented significantly higher area under curve (AUC) than the Cobas assay (1.000 vs 0.880; P = 0.0002). The Abbott assay demonstrated extremely low PCR inhibition on clinical respiratory specimens. The automated Abbott assay required only very short manual handling time (0.5 h), which could help to improve the laboratory management. In the prospective analysis, the overall estimates for sensitivity and specificity of the Abbott assay were both 100 % among smear-positive specimens, whereas the smear-negative specimens were 96.7 and 96.1 %, respectively. No cross-reactivity with non-tuberculosis mycobacterial species was observed. The superiority in sensitivity of the Abbott assay for detecting MTBC in smear-negative specimens could further minimize the risk in MTBC false-negative detection. The new Abbott RealTime MTB assay has good diagnostic performance which can be a useful diagnostic tool for rapid MTBC detection in clinical laboratories.

  13. Objective-prism spectrophotometry of quasars

    International Nuclear Information System (INIS)

    Clowes, R.G.

    1980-01-01

    A procedure is derived for obtaining low-resolution spectrophotometry of quasars directly from the objective-prism plates on which they were discovered. Measurements with a PDS microdensitometer of approximately 130 quasar candidates in approximately the central 19 square degrees of the UK Schmidt prism plate UJ3682P were used in the application of the procedure. The success of the objective-prism spectrophotometry is demonstrated in a comparison with 12 slit spectra. Redshifts and equivalent widths can be determined with typical discrepancies of 1% and 40% respectively. This work on objective-prism spectrophotometry leads to a quantification of the selection effects that operate in the searches for emission-line objects on objective-prism plates. The quantification successfully explains an apparent discrepancy in the detection efficiencies of the CTIO-4m and Curtis Schmidt surveys for quasars. Spectra of quasars that were observed with the Image Photon Counting System on the Anglo-Australian Telescope are presented. The observations of quasars with broad absorption troughs indicate the ejection of matter with velocities up to approximately 22000kms -1 and with velocity dispersions up to approximately 11000kms -1 . Data on the wavelength dependences of the contrast γ and the grain response function g of the Kodak emulsion IIIaJ are presented. (author)

  14. Virus-specific immune response in HBeAg-negative chronic hepatitis B: relationship with clinical profile and HBsAg serum levels.

    Directory of Open Access Journals (Sweden)

    Elisabetta Loggi

    Full Text Available BACKGROUND AIMS: The immune impairment characterizing chronic hepatitis B (cHBV infection is thought to be the consequence of persistent exposure to viral antigens. However, the immune correlates of different clinical stages of cHBV and their relation with different levels of HBsAg have not been investigated. The aim of the present study was to evaluate the relationship between HBV-specific T cells response and the degree of in vivo HBV control and HBsAg serum levels in HBeAg-HBeAb+ cHBV. METHODS: Peripheral blood mononuclear cells from 42 patients with different clinical profiles (treatment-suppressed, inactive carriers and active hepatitis of cHBV, 6 patients with resolved HBV infection and 10 HBV-uninfected individuals were tested with overlapping peptides spanning the entire HBV proteome. The frequency and magnitude of HBV-specific T cell responses was assessed by IFNγ ELISPOT assay. Serum HBsAg was quantified with a chemiluminescent immunoassay. RESULTS: The total breadth and magnitude of HBV-specific T cell responses did not differ significantly between the four groups. However, inactive carriers targeted preferentially the core region. In untreated patients, the breadth of the anti-core specific T cell response was inversely correlated with serum HBsAg concentrations as well as HBV-DNA and ALT levels and was significantly different in patients with HBsAg levels either above or below 1000 IU/mL. The same inverse association between anti-core T cell response and HBsAg levels was found in treated patients. CONCLUSIONS: Different clinical outcomes of cHBV infection are associated with the magnitude, breadth and specificity of the HBV-specific T cell response. Especially, robust anti-core T cell responses were found in the presence of reduced HBsAg serum levels, suggesting that core-specific T cell responses can mediate a protective effect on HBV control.

  15. Detection of hepatitis B virus infection in HBsAg-negative patients by monoclonal antibodies against HBsAg

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Y K

    1986-11-01

    The technique of producing antibody secreting hybridomas has made available high-affinity antibodies of predefined specificity for use as diagnostic reagents. Recently, high-affinity monoclonal antibodies to hepatitis B surface antigens (HBsAg) were produced and characterized. Immunoassay was developed using these antibodies for the detection of HBsAg-associated determinants. The present study indicated the significance of the enhanced detection by monoclonal radioimmunoassay (M-RIA) of HBsAg in sera of patients with hepatitis B virus infection. The M-RIA detected HBsAg in sera of hemodialysis patients and blood donor defined as HBsAg-negative by polyclonal RIA (2.2 %, 0.14 %, respectively). Furthermore, individuals with chronic liver diseases were reactive only in the M-RIA (chronic hepatitis 4.8 %, liver cirrhosis 10.0 %, hepatocellular carcinoma 22.2 %). It is noteworthy that some of these patients were diagnosesed as so-called non-A non-B hepatitis because of no serological markers of hepatitis B virus infection such as HBsAb and HBcAb. The enhanced performance of the monoclonal RIA compared to conventional RIA was due to the increased sensitivity of the assay (55 pg vs 230 pg/ml). In immunohistochemical study, one of the monoclonal antibody named 5C3 was applied for detection of HBsAg in the formalin-fixed paraffin-embedded liver. HBsAg was detected in 6 out of 41 HBsAg-seronegative liver specimen. Thus, the studies showed the importance of the clinical application of monoclonal antibodies such as immunoassay and immunohistochemical study in the diagnosis of hepatitis B virus infection.

  16. Detection of hepatitis B virus infection in HBsAg-negative patients by monoclonal antibodies against HBsAg

    International Nuclear Information System (INIS)

    Fujita, Y.K.

    1986-01-01

    The technique of producing antibody secreting hybridomas has made available high-affinity antibodies of predefined specificity for use as diagnostic reagents. Recently, high-affinity monoclonal antibodies to hepatitis B surface antigens (HBsAg) were produced and characterized. Immunoassay was developed using these antibodies for the detection of HBsAg-associated determinants. The present study indicated the significance of the enhanced detection by monoclonal radioimmunoassay (M-RIA) of HBsAg in sera of patients with hepatitis B virus infection. The M-RIA detected HBsAg in sera of hemodialysis patients and blood donor defined as HBsAg-negative by polyclonal RIA (2.2 %, 0.14 %, respectively). Furthermore, individuals with chronic liver diseases were reactive only in the M-RIA (chronic hepatitis 4.8 %, liver cirrhosis 10.0 %, hepatocellular carcinoma 22.2 %). It is noteworthy that some of these patients were diagnosesed as so-called non-A non-B hepatitis because of no serological markers of hepatitis B virus infection such as HBsAb and HBcAb. The enhanced performance of the monoclonal RIA compared to conventional RIA was due to the increased sensitivity of the assay (55 pg vs 230 pg/ml). In immunohistochemical study, one of the monoclonal antibody named 5C3 was applied for detection of HBsAg in the formalin-fixed paraffin-embedded liver. HBsAg was detected in 6 out of 41 HBsAg-seronegative liver specimen. Thus, the studies showed the importance of the clinical application of monoclonal antibodies such as immunoassay and immunohistochemical study in the diagnosis of hepatitis B virus infection. (author)

  17. Dynamic changes in brain activity during prism adaptation.

    Science.gov (United States)

    Luauté, Jacques; Schwartz, Sophie; Rossetti, Yves; Spiridon, Mona; Rode, Gilles; Boisson, Dominique; Vuilleumier, Patrik

    2009-01-07

    Prism adaptation does not only induce short-term sensorimotor plasticity, but also longer-term reorganization in the neural representation of space. We used event-related fMRI to study dynamic changes in brain activity during both early and prolonged exposure to visual prisms. Participants performed a pointing task before, during, and after prism exposure. Measures of trial-by-trial pointing errors and corrections allowed parametric analyses of brain activity as a function of performance. We show that during the earliest phase of prism exposure, anterior intraparietal sulcus was primarily implicated in error detection, whereas parieto-occipital sulcus was implicated in error correction. Cerebellum activity showed progressive increases during prism exposure, in accordance with a key role for spatial realignment. This time course further suggests that the cerebellum might promote neural changes in superior temporal cortex, which was selectively activated during the later phase of prism exposure and could mediate the effects of prism adaptation on cognitive spatial representations.

  18. Porro prism lasers: a new perspective

    Science.gov (United States)

    Burger, Liesl; Forbes, Andrew

    2008-08-01

    Porro prism lasers are insensitive to misalignment caused by, for example, shock and temperature variation, making them useful in field applications, for example in target designation and range-finding systems. This property is a result of the property of Porro prisms that they return a reflected beam parallel to the incident beam, regardless of any tilt on the prism. These lasers are generally used in a marginally stable or unstable configuration for low divergence, but in the stable configuration some interesting kaleidoscope modes can be modelled. In previous work on Porro prism resonators we formulated an analytical method of determining which Porro angles resonate and result in petal output modes, as well as the corresponding number of petals. This work has been verified using a numerical model as well as experimentally. We have developed this work further and have investigated the losses associated with a range of Porro angles as well as the effects of these losses on the resulting modes. We conclude by summarizing the design considerations for Porro prism lasers.

  19. Detection of Mycobacterium tuberculosis Complex in Paraffin-Embedded Tissues by the New Automated Abbott RealTime MTB Assay.

    Science.gov (United States)

    Fu, Yung-Chieh; Liao, I-Chuang; Chen, Hung-Mo; Yan, Jing-Jou

    2016-07-01

    The Abbott RealTime MTB assay, launched in June 2014, has been shown to have a competitive performance in the detection of the Mycobacterium tuberculosis (MTB) complex in respiratory specimens. The present study was conducted to investigate the usefulness of the Abbott MTB Realtime assay in the detection of MTB in formalin-fixed paraffin-embedded (FFPE) tissues. A total of 96 FFPE specimens obtained from microbiologically proven MTB cases (N=60) and nontuberculous Mycobacterium cases (N=36) were analyzed. The performance of the Abbott MTB Realtime assay was compared with that of the Roche Cobas TaqMan MTB assay. The overall sensitivity and specificity of the Abbott assay were 63.3% and 97.2%, respectively, compared with 11.7% and 100% for the Cobas assay. The detection rate of the Abbott assay was much higher among 37 acid-fast-positive specimens than among 23 acid-fast-negative specimens (89.3% versus 21.7%, respectively). The detection rate of the assay was higher among 29 resection specimens than among 31 small biopsy specimens (86.2% versus 41.9%, respectively). Our results suggest that the Abbott RealTime MTB assay can be used to differentiate MTB from nontuberculous mycobacterial infections in acid-fast-positive FFPE tissues. © 2016 by the Association of Clinical Scientists, Inc.

  20. Behaviour and strength assessment of masonry prisms

    Directory of Open Access Journals (Sweden)

    Nassif Nazeer Thaickavil

    2018-06-01

    Full Text Available This is a case study presenting the cracking behavior and assessment of the compressive strength of masonry prisms. The compressive strength of masonry was determined by performing laboratory tests on 192 masonry prism specimens corresponding to 3 specimens each in 64 groups. The variables considered in the experimental program are type of brick, strength of masonry and height-to-thickness (h/t ratio of the prism specimen. Pressed earth bricks and burnt clay bricks were used for the preparation of masonry prisms. A mathematical model is also proposed for the estimation of compressive strength of masonry prisms by performing a statistical multiple regression analysis on 232 data sets, which includes 64 test data from the present study and 168 test data published in the literature. The model was developed based on the regression analysis of test data of prisms made of a variety of masonry units namely clay bricks, pressed earth bricks, concrete blocks, calcium silicate bricks, stone blocks, perforated bricks and soft mud bricks. The proposed model not only accounts for the wide ranges of compressive strengths of masonry unit and mortar, but also accounts for the influence of volume fractions of masonry unit and mortar in addition to the height-to-thickness ratio. The predicted compressive strength of prisms using the proposed model is compared with 14 models available in published literature. The predicted strength was found to be in good agreement with the corresponding experimental data. Keywords: Prism strength, Stack bonded masonry, Running bonded masonry, Masonry unit strength, Cracking

  1. Evaluation of the Abbott Real Time HCV genotype II assay for Hepatitis C virus genotyping.

    Science.gov (United States)

    Sariguzel, Fatma Mutlu; Berk, Elife; Gokahmetoglu, Selma; Ercal, Baris Derya; Celik, Ilhami

    2015-01-01

    The determination of HCV genotypes and subtypes is very important for the selection of antiviral therapy and epidemiological studies. The aim of this study was to evaluate the performance of Abbott Real Time HCV Genotype II assay in HCV genotyping of HCV infected patients in Kayseri, Turkey. One hundred patients with chronic hepatitis C admitted to our hospital were evaluated between June 2012 and December 2012, HCV RNA levels were determined by the COBAS® AmpliPrep/COBAS® TaqMan® 48 HCV test. HCV genotyping was investigated by the Abbott Real Time HCV Genotype II assay. With the exception of genotype 1, subtypes of HCV genotypes could not be determined by Abbott assay. Sequencing analysis was used as the reference method. Genotypes 1, 2, 3 and 4 were observed in 70, 4, 2 and 24 of the 100 patients, respectively, by two methods. The concordance between the two systems to determine HCV major genotypes was 100%. Of 70 patients with genotype 1, 66 showed infection with subtype 1b and 4 with subtype 1a by Abbott Real Time HCV Genotype II assay. Using sequence analysis, 61 showed infection with subtype 1b and 9 with subtype 1a. In determining of HCV genotype 1 subtypes, the difference between the two methods was not statistically significant (P>0.05). HCV genotype 4 and 3 samples were found to be subtype 4d and 3a, respectively, by sequence analysis. There were four patients with genotype 2. Sequence analysis revealed that two of these patients had type 2a and the other two had type 2b. The Abbott Real Time HCV Genotype II assay yielded results consistent with sequence analysis. However, further optimization of the Abbott Real Time HCV Genotype II assay for subtype identification of HCV is required.

  2. An improved prism for use in laser resonators

    Science.gov (United States)

    Richards, J.

    1981-08-01

    The use of compound total internal reflection prisms rather than Porro prisms in polarisation coupled lasers is proposed. Performance advantages resulting from the use of these prisms include higher output without the need to bias the Pockels cell, ability to give a larger range of output coupling and independence of performance on the refractive index of the prism. In conventional Q-switched lasers the use of the prism at the Pockels cell end of the resonator instead of the usual 100% reflecting mirror also leads to some advantages including better hold-off, elimination of the need to bias the Pockels cell and insensitivity in one plane to angular misalignment.

  3. Seropositivity of HBsAg, anti-HCV and anti-HIV in preoperative patients

    Directory of Open Access Journals (Sweden)

    Berrin Karaayak Uzun

    2014-12-01

    Full Text Available Objective: The infections caused by human immunodeficiency virus (HIV, hepatitis B (HBV and C (HCV viruses pose a serious occupational risk for the healthcare workers especially those in emergency services, laboratories and surgery wards. Vaccination and establishment of the strict biosafety procedures are the main principles to prevent blood-borne infections in healthcare workers. Additionally, serological screening of the preoperative patients could decrease the risk for exposure. In this study, we aimed to determine the seroprevalence of HBsAg, anti-HCV, anti-HIV 1/2 in preoperative patients. Methods: Hospital automation records were evaluated retrospectively for 4.367 patients who were scheduled for surgery and scanned for anti-HIV 1/2, HBsAg and anti-HCV as preoperative procedures in the preparation period of operation between January 2012 and December 2012. Results: HBsAg positivity rate was found in 7.7% (n=336, anti-HCV positivity rate was found in 2.3% (n=101. A two (0.05% of five patients were positive for anti-HIV 1/2 was found positive verification test and the other three samples were accepted as false positive test results. Conclusion: All healthcare workers must be trained about occupational diseases and vaccinated against Hepatitis B. Universal precautions must be strictly followed particularly in the operating room. In addition, all patients should be considered as potential carriers regarded as a carrier of the potential for infection. J Clin Exp Invest 2013; 4 (4: 449-452

  4. Membranous glomerulonephritis in a child asymptomatic for hepatitis B virus. Concomitant seropositivity for HBsAG and anti-HBs.

    Science.gov (United States)

    Hirsch, H Z; Ainsworth, S K; DeBeukelaer, M; Brissie, R M; Hennigar, G R

    1981-04-01

    The presence of hepatitis B surface antigen (HBsAg) in association with immunoglobulins and complement components within the glomerular basement membranes of adults having chronic active hepatitis has been well documented. In addition, investigators in Poland have demonstrated HBsAg immune complexes in glomeruli of children who did not have clinical evidence of hepatitis. More recently, a single case of childhood membranous glomerulonephritis in an asymptomatic carrier of hepatitis B virus was cited by observers in Canada. Reported here is the deposition of HBsAg immune complexes in the glomerular basement membranes of a 13-year-old black boy who had membranous glomerulopathy but not clinical evidence of hepatitis. This may be the first reported case in the United States of HbsAg-associated membranous glomerulonephritis in a child asymptomatic for hepatitis B virus, and only the second such case in North America. However, unlike previous studies of childhood glomerulopathy in association with hepatitis B virus, this patient is seropositive for both HBsAg and anti-HBs (antibody for hepatitis B surface antigen). Similar "rare" serologic findings were found for the patient's eldest male sib.

  5. Serologic tracers (HBsAg and HBsAc) of hepatitis B virus in expectant mothers of the Perinatal Maternal Institute

    International Nuclear Information System (INIS)

    Garcia G, B.M.

    1997-01-01

    A study on hepatitis B tracers, (HBsAg and HBsAc), was conducted in women with different months of pregnancy at the Perinatal Maternal Institute in Lima, Peru. A total of 1010 mothers were studied during the period of January to October 1996, establishing by radioimmunoassay (RIA) whether they were positive or not. The results showed a prevalence rate of 1,6 for HBsAc and 1,3 for HBsAg for every 100,000 inhabitants. The incidence rate was 0,332 for HBsAc and 0,07 for HBsAg for every 100,000 inhabitants. This means that 21 expectant mothers are HBsAc positive and 5 are HBsAg positive. According to the investigations, there were different ways of transmission; promiscuity must be highlighted, as well as age -most of the mothers who were positive were between 20 and 25 years old- and origin. Most of them were immigrants from different places and live in shantytowns, which indicates that most of them have limited economic resources and have not received any orientation on family planning

  6. Cerebellar inactivation impairs memory of learned prism gaze-reach calibrations.

    Science.gov (United States)

    Norris, Scott A; Hathaway, Emily N; Taylor, Jordan A; Thach, W Thomas

    2011-05-01

    Three monkeys performed a visually guided reach-touch task with and without laterally displacing prisms. The prisms offset the normally aligned gaze/reach and subsequent touch. Naive monkeys showed adaptation, such that on repeated prism trials the gaze-reach angle widened and touches hit nearer the target. On the first subsequent no-prism trial the monkeys exhibited an aftereffect, such that the widened gaze-reach angle persisted and touches missed the target in the direction opposite that of initial prism-induced error. After 20-30 days of training, monkeys showed long-term learning and storage of the prism gaze-reach calibration: they switched between prism and no-prism and touched the target on the first trials without adaptation or aftereffect. Injections of lidocaine into posterolateral cerebellar cortex or muscimol or lidocaine into dentate nucleus temporarily inactivated these structures. Immediately after injections into cortex or dentate, reaches were displaced in the direction of prism-displaced gaze, but no-prism reaches were relatively unimpaired. There was little or no adaptation on the day of injection. On days after injection, there was no adaptation and both prism and no-prism reaches were horizontally, and often vertically, displaced. A single permanent lesion (kainic acid) in the lateral dentate nucleus of one monkey immediately impaired only the learned prism gaze-reach calibration and in subsequent days disrupted both learning and performance. This effect persisted for the 18 days of observation, with little or no adaptation.

  7. Serological profile of incidentally detected asymptomatic HBsAg positive subjects (IDAHS)

    International Nuclear Information System (INIS)

    Khokhar, N.; Gill, M.L.

    2004-01-01

    Objective: To evaluate the serological profile of patients with incidentally detected positive hepatitis-B surface antigen (HBsAg) and to asses the risk factors. Design: An observational study. Place and Duration of Study: This study was conducted at Shifa International Hospital, Islamabad from 1999 to 2003. Patients and Methods: All patients who presented to gastroenterology clinic of Shifa Intentional Hospital, Islamabad with positive HBsAg, detected incidentally, were tested for alamine transaminase (ALT), hepatitis Beantigen (HBeAg) and in certain cases hepatitis-B virus DNA (HBV DNA) by polymerase chain reaction (PCR). Their risk factors for acquisition of infection were assessed with specific questions. Results: A total of 224 patients were examined. One hundred sixty-four (73.2%) were male and 60 (26.8%) female. Mean age of all the subjects was 32.45 plus minus 11.85 years. Out of 224 patients, 48 (21.4%) were positive for HBeAg and 176 (78.6%) were negative. Out of 48 subjects who were positive for HBeAg, 36 underwent HBV DNA determination and 32 (88.8%) were positive for HBV DNA. Out of 176 subjects who had negative HBeAg, 46 had elevated ALT and in those HBV DNA was performed and 14 had positive HBV DNA. Most common risk factors detected in these patients were intramuscular injections and surgery, however, in a large number, risk factors were unknown. Conclusion: Twenty-one percent asymptomatic subjects with positive HBsAg were found to be HBeAg positive. A large number of subjects with negative HBeAg had HBV DNA positive suggesting presence of precore mutants. Intramuscular injections and surgery were noted to be frequent risk factors in these subjects. (author)

  8. HBsAg carrier status and the association between gestational diabetes with increased serum ferritin concentration in Chinese women.

    Science.gov (United States)

    Lao, Terence T; Tse, Ka-Yu; Chan, Louis Y; Tam, Kar-Fai; Ho, Lai-Fong

    2003-11-01

    To determine whether the high prevalence of hepatitis B surface antigen (HBsAg) carriage in our population can explain the previous observation of an association between increased maternal serum ferritin concentration and gestational diabetes in Hong Kong Chinese women. A retrospective study was performed on 767 nonanemic women with singleton pregnancy who had iron status assessed at 28-30 weeks. The result of the routine antenatal HBsAg screening was retrieved from patient records. The HBsAg-positive and -negative groups were compared for maternal characteristics, prevalence of gestational diabetes in the third trimester, prevalence of high serum ferritin and iron concentrations, and transferrin saturation, which is defined as a value in the highest quartile established by the measurements obtained from the HBsAg-negative group. The incidences of oral glucose tolerance test and gestational diabetes were significantly increased in the HBsAg-positive group. The HBsAg-positive women with gestational diabetes had significantly increased prevalence of high serum ferritin compared with the HBsAg-negative women, irrespective of the latter's gestational diabetes status. Multiple logistic regression analysis confirmed the independent association between HBsAg carrier status with gestational diabetes (relative risk 3.51, 95% CI 1.83-6.73) but excluded high ferritin as an independent factor. Our results indicate that maternal HBsAg carriage could explain in part the association between increased serum ferritin concentration with gestational diabetes in Hong Kong Chinese women, and that HBsAg carrier status is an independent risk factor for gestational diabetes.

  9. Effect of using heat-inactivated serum with the Abbott human T-cell lymphotropic virus type III antibody test.

    OpenAIRE

    Jungkind, D L; DiRenzo, S A; Young, S J

    1986-01-01

    The Abbott enzyme immunoassay (Abbott Laboratories, North Chicago, Ill.) for human T-cell lymphotropic virus type III (HTLV-III) antibody was evaluated to determine the effect of using heat-inactivated (56 degrees C for 30 min) serum as the sample. Each of 58 nonreactive serum samples gave a higher A492 value when tested after heat inactivation. Ten of the samples became reactive after heating. Heat-inactivated serum should not be used in the current Abbott HTLV-III antibody test, because thi...

  10. Comparison of the Abbott RealTime High Risk HPV test and the Roche cobas 4800 HPV test using urine samples.

    Science.gov (United States)

    Lim, Myong Cheol; Lee, Do-Hoon; Hwang, Sang-Hyun; Hwang, Na Rae; Lee, Bomyee; Shin, Hye Young; Jun, Jae Kwan; Yoo, Chong Woo; Lee, Dong Ock; Seo, Sang-Soo; Park, Sang-Yoon; Joo, Jungnam

    2017-05-01

    Human papillomavirus (HPV) testing based on cervical samples is important for use in cervical cancer screening. However, cervical sampling is invasive. Therefore, non-invasive methods for detecting HPV, such as urine samples, are needed. For HPV detection in urine samples, two real-time PCR (RQ-PCR) tests, Roche cobas 4800 test (Roche_HPV; Roche Molecular Diagnostics) and Abbott RealTime High Risk HPV test (Abbott_HPV; Abbott Laboratories) were compared to standard cervical samples. The performance of Roche_HPV and Abbott_HPV for HPV detection was evaluated at the National Cancer Center using 100 paired cervical and urine samples. The tests were also compared using urine samples stored at various temperatures and for a range of durations. The overall agreement between the Roche_HPV and Abbott_HPV tests using urine samples for any hrHPV type was substantial (86.0% with a kappa value of 0.7173), and that for HPV 16/18 was nearly perfect (99.0% with a kappa value of 0.9668). The relative sensitivities (based on cervical samples) for HPV 16/18 detection using Roche_HPV and Abbott_HPV with urine samples were 79.2% (95% CI; 57.9-92.9%) and 81.8% (95% CI; 59.7-94.8%), respectively. When the cut-off C T value for Abbott_HPV was extended to 40 for urine samples, the relative sensitivity of Abbott_HPV increased to 91.7% from 81.8% for HPV16/18 detection and to 87.0% from 68.5% for other hrHPV detection. The specificity was not affected by the change in the C T threshold. Roche_HPV and Abbott_HPV showed high concordance. However, HPV DNA detection using urine samples was inferior to HPV DNA detection using cervical samples. Interestingly, when the cut-off C T value was set to 40, Abbott_HPV using urine samples showed high sensitivity and specificity, comparable to those obtained using cervical samples. Fully automated DNA extraction and detection systems, such as Roche_HPV and Abbott_HPV, could reduce the variability in HPV detection and accelerate the standardization of HPV

  11. Simulated Prism Therapy in Virtual Reality produces larger after-effects than standard prism exposure in normal healthy subject - Implications for Neglect Therapy

    DEFF Research Database (Denmark)

    Wilms, Inge Linda

    2018-01-01

    BACKGROUND: Virtual reality is an important area of exploration within computer-based cognitive rehabilitation of visual neglect. Virtual reality will allow for closer monitoring of patient behaviour during prism adaptation therapy and perhaps change the way we induce prismatic after......-effects. OBJECTIVE: This study compares the effect of two different prism simulation conditions in virtual reality to a standard exposure to prism goggles after one session of Prism Adaptation Therapy in healthy subjects. METHOD: 20 healthy subjects were subjected to one session of prism adaptation therapy under...... training for rehabilitation of hemi spatial attentional deficits such as visual neglect....

  12. Calibration of the Wedge Prism

    Science.gov (United States)

    Charles B. Briscoe

    1957-01-01

    Since the introduction of plotless cruising in this country by Grosenbaugh and the later suggestion of using a wedge prism as an angle gauge by Bruce this method of determining basal area has been widely adopted in the South. One of the factors contributing to the occasionally unsatisfactory results obtained is failure to calibrate the prism used. As noted by Bruce the...

  13. Prism. Volume 1, Number 1, December 2009

    Science.gov (United States)

    2009-12-01

    strategy, regional security affairs, and global strategic problems. This is the authoritative , official U.S. Department of Defense edition of PRISM...suffer from illiteracy, poor health, and extreme poverty PRISM 1, no. 1 FRoM the FIeld | 89 The country’s maternal mortality and female illiteracy rates...problems. This is the authoritative , official U.S. Department of Defense edition of PRISM. Any copyrighted portions of this journal may not be

  14. GE advanced liquid metal reactor S-PRISM

    International Nuclear Information System (INIS)

    Boardman, C.

    2001-01-01

    This presentation covers the following topics: Incentive for developing S-PRISM; Design and safety approach; Design description and competitive potential; Previous Licensing interactions; Planned approach to Licensing S-PRISM

  15. Performance characteristics and comparison of Abbott and artus real-time systems for hepatitis B virus DNA quantification.

    Science.gov (United States)

    Ismail, Ashrafali M; Sivakumar, Jayashree; Anantharam, Raghavendran; Dayalan, Sujitha; Samuel, Prasanna; Fletcher, Gnanadurai J; Gnanamony, Manu; Abraham, Priya

    2011-09-01

    Virological monitoring of hepatitis B virus (HBV) DNA is critical to the management of HBV infection. With several HBV DNA quantification assays available, it is important to use the most efficient testing system for virological monitoring. In this study, we evaluated the performance characteristics and comparability of three HBV DNA quantification systems: Abbott HBV real-time PCR (Abbott PCR), artus HBV real-time PCR with QIAamp DNA blood kit purification (artus-DB), and artus HBV real-time PCR with the QIAamp DSP virus kit purification (artus-DSP). The lower limits of detection of these systems were established against the WHO international standards for HBV DNA and were found to be 1.43, 82, and 9 IU/ml, respectively. The intra-assay and interassay coefficients of variation of plasma samples (1 to 6 log(10) IU/ml) ranged between 0.05 to 8.34% and 0.16 to 3.48% for the Abbott PCR, 1.53 to 26.85% and 0.50 to 12.89% for artus-DB, and 0.29 to 7.42% and 0.94 to 3.01% for artus-DSP, respectively. Ninety HBV clinical samples were used for comparison of assays, and paired quantitative results showed strong correlation by linear regression analysis (artus-DB with Abbott PCR, r = 0.95; Abbott PCR with artus-DSP, r = 0.97; and artus-DSP with artus-DB, r = 0.94). Bland-Altman analysis showed a good level of agreement for Abbott PCR and artus-DSP, with a mean difference of 0.10 log(10) IU/ml and limits of agreement of -0.91 to 1.11 log(10) IU/ml. No genotype-specific bias was seen in all three systems for HBV genotypes A, C, and D, which are predominant in this region. This finding illustrates that the Abbott real-time HBV and artus-DSP systems show more comparable performance than the artus-DB system, meeting the current guidelines for assays to be used in the management of hepatitis B.

  16. PRISM

    Science.gov (United States)

    2017-12-21

    societal issues , given countervailing moral , legal, and ethical interpretations, as well as suspicions PRISM 7, NO. 2 FEATURES | 13 COGNITIVE-EMOTIONAL...to tell our story. Additionally, U.S. practi- tioners are bound by asymmetric legal, moral , and ethical constraints that often keep them from being...the founder of SpaceX and Tesla, withdrew from two business councils providing advice to the administration on economic issues . Further driving

  17. Technology evaluation: adalimumab, Abbott laboratories.

    Science.gov (United States)

    Lorenz, Hanns M

    2002-04-01

    Adalimumab (D2E7), a human monoclonal antibody that binds to and neutralizes TNFa, is being developed by Abbott (formerly Knoll), under license from Cambridge Antibody Technology (CAT), for the potential treatment of inflammatory disorders such as rheumatoid arthritis (RA) and Crohn's disease. It is also being investigated for the potential treatment of coronary heart disease. Phase II studies for Crohn's disease and phase III for RA were ongoing throughout 2001. Limited data are only available for RA. In January 2002, it was reported that phase III trials of adalimumab for RA had been completed, but details have not been published in the primary literature so far. At this time CAT and Abbott expected to file for US approval in the second quarter of 2002 with a launch date anticipated for 2003. Phase III data are expected to be presented at the European League Against Rheumatism meeting in June 2002. In November 2000, Lehman Brothers predicted a US launch in June 2002 with peak US sales of $600 million in 2007 and a launch in non-US markets in 2003 with peak sales in these markets of $300 million in 2008. In December 2000, Merrill Lynch predicted regulatory clearance in the second half of 2003. The probability of adalimumab reaching the market is estimated to be 70%. In December 2000, Merrill Lynch predicted a 2003 launch, with estimated sales of pounds sterling 3.65 million in that year rising to pounds sterling 30.14 million in 2010. In March 2001, ABN AMRO predicted sales of $73 million in 2003 rising to $392 million in 2007.

  18. Modeling laser brightness from cross Porro prism resonators

    Science.gov (United States)

    Forbes, Andrew; Burger, Liesl; Litvin, Igor Anatolievich

    2006-08-01

    Laser brightness is a parameter often used to compare high power laser beam delivery from various sources, and incorporates both the power contained in the particular mode, as well as the propagation of that mode through the beam quality factor, M2. In this study a cross Porro prism resonator is considered; crossed Porro prism resonators have been known for some time, but until recently have not been modeled as a complete physical optics system that allows the modal output to be determined as a function of the rotation angle of the prisms. In this paper we consider the diffraction losses as a function of the prism rotation angle relative to one another, and combine this with the propagation of the specific modes to determine the laser output brightness as a function of the prism orientation.

  19. Berenice Abbott (1898-1991, photographies

    Directory of Open Access Journals (Sweden)

    Juliette Mélia

    2012-05-01

    Full Text Available C’est la première fois que Berenice Abbott est exposée à Paris. Les cent vingt images et trente documents présentés au Jeu de Paume sont regroupés en quatre grandes séries, qui correspondent aux quatre grandes phases de sa carrière photographique. La première partie retrace son œuvre de portraitiste, qui commence à Paris au début des années 1920, où elle photographie des anonymes, mais aussi beaucoup d’artistes et d’écrivains tels que Marcel Duchamp, Jean Cocteau, James Joyce, ou encore Djuna...

  20. The effect of compliant prisms on subduction zone earthquakes and tsunamis

    Science.gov (United States)

    Lotto, Gabriel C.; Dunham, Eric M.; Jeppson, Tamara N.; Tobin, Harold J.

    2017-01-01

    Earthquakes generate tsunamis by coseismically deforming the seafloor, and that deformation is largely controlled by the shallow rupture process. Therefore, in order to better understand how earthquakes generate tsunamis, one must consider the material structure and frictional properties of the shallowest part of the subduction zone, where ruptures often encounter compliant sedimentary prisms. Compliant prisms have been associated with enhanced shallow slip, seafloor deformation, and tsunami heights, particularly in the context of tsunami earthquakes. To rigorously quantify the role compliant prisms play in generating tsunamis, we perform a series of numerical simulations that directly couple dynamic rupture on a dipping thrust fault to the elastodynamic response of the Earth and the acoustic response of the ocean. Gravity is included in our simulations in the context of a linearized Eulerian description of the ocean, which allows us to model tsunami generation and propagation, including dispersion and related nonhydrostatic effects. Our simulations span a three-dimensional parameter space of prism size, prism compliance, and sub-prism friction - specifically, the rate-and-state parameter b - a that determines velocity-weakening or velocity-strengthening behavior. We find that compliant prisms generally slow rupture velocity and, for larger prisms, generate tsunamis more efficiently than subduction zones without prisms. In most but not all cases, larger, more compliant prisms cause greater amounts of shallow slip and larger tsunamis. Furthermore, shallow friction is also quite important in determining overall slip; increasing sub-prism b - a enhances slip everywhere along the fault. Counterintuitively, we find that in simulations with large prisms and velocity-strengthening friction at the base of the prism, increasing prism compliance reduces rather than enhances shallow slip and tsunami wave height.

  1. Analysis of unscrammed events in PRISM

    International Nuclear Information System (INIS)

    Slovik, G.C.; Van Tuyle, G.J.

    1990-01-01

    The PRISM reactor is presently under pre-application licensing review by the NRC, with Brookhaven National Laboratory (BNL) providing technical assistance. The purpose of this paper is to review the current PRISM design and describe the results from the SSC Code calculations performed at BNL, for a series of unscrammed accidents. 3 refs., 5 figs

  2. Strongly-Refractive One-Dimensional Photonic Crystal Prisms

    Science.gov (United States)

    Ting, David Z. (Inventor)

    2004-01-01

    One-dimensional (1D) photonic crystal prisms can separate a beam of polychromatic electromagnetic waves into constituent wavelength components and can utilize unconventional refraction properties for wavelength dispersion over significant portions of an entire photonic band rather than just near the band edges outside the photonic band gaps. Using a ID photonic crystal simplifies the design and fabrication process and allows the use of larger feature sizes. The prism geometry broadens the useful wavelength range, enables better optical transmission, and exhibits angular dependence on wavelength with reduced non-linearity. The properties of the 1 D photonic crystal prism can be tuned by varying design parameters such as incidence angle, exit surface angle, and layer widths. The ID photonic crystal prism can be fabricated in a planar process, and can be used as optical integrated circuit elements.

  3. Verification of Abbott 25-OH-vitamin D assay on the architect system

    Directory of Open Access Journals (Sweden)

    Katrina Hutchinson

    2017-04-01

    Full Text Available Objectives: Analytical and clinical verification of both old and new generations of the Abbott total 25-hydroxyvitamin D (25OHD assays, and an examination of reference Intervals. Methods: Determination of between-run precision, and Deming comparison between patient sample results for 25OHD on the Abbott Architect, DiaSorin Liaison and AB SCIEX API 4000 (LC-MS/MS. Establishment of uncertainty of measurement for 25OHD Architect methods using old and new generations of the reagents, and estimation of reference interval in healthy Irish population. Results: For between-run precision the manufacturer claims 2.8% coefficients of variation (CVs of 2.8% and 4.6% for their high and low controls, respectively. Our instrument showed CVs between 4% and 6.2% for all levels of the controls on both generations of the Abbott reagents. The between-run uncertainties were 0.28 and 0.36, with expanded uncertainties 0.87 and 0.98 for the old and the new generations of reagent, respectively. The difference between all methods used for patients’ samples was within total allowable error, and the instruments produced clinically equivalent results. The results covered the medical decision points of 30, 40, 50 and 125 nmol/L. The reference interval for total 25OHD in our healthy Irish subjects was lower than recommended levels (24–111 nmol/L. Conclusion: In a clinical laboratory Abbott 25OHD immunoassays are a useful, rapid and accurate method for measuring total 25OHD. The new generation of the assay was confirmed to be reliable, accurate, and a good indicator for 25OHD measurement. More study is needed to establish reference intervals that correctly represent the healthy population in Ireland.

  4. Spatial compression impairs prism-adaptation in healthy individuals

    Directory of Open Access Journals (Sweden)

    Rachel J Scriven

    2013-05-01

    Full Text Available Neglect patients typically present with gross inattention to one side of space following damage to the contralateral hemisphere. While prism-adaptation is effective in ameliorating some neglect behaviours, the mechanisms involved and their relationship to neglect remain unclear. Recent studies have shown that conscious strategic control processes in prism-adaptation may be impaired in neglect patients, who are also reported to show extraordinarily long aftereffects compared to healthy participants. Determining the underlying cause of these effects may be the key to understanding therapeutic benefits. Alternative accounts suggest that reduced strategic control might result from a failure to detect prism-induced reaching errors properly either because a the size of the error is underestimated in compressed visual space or b pathologically increased error detection thresholds reduce the requirement for error correction. The purpose of this study was to model these two alternatives in healthy participants and to examine whether strategic control and subsequent aftereffects were abnormal compared to standard prism adaptation. Each participant completed three prism-adaptation procedures within a MIRAGE mediated reality environment with direction errors recorded before, during and after adaptation. During prism-adaptation, visual-feedback of the reach could be compressed, perturbed by noise or represented veridically. Compressed visual space significantly reduced strategic control and aftereffects compared to control and noise conditions. These results support recent observations in neglect patients, suggesting that a distortion of spatial representation may successfully model neglect and explain neglect performance while adapting to prisms.

  5. Simple Tidal Prism Models Revisited

    Science.gov (United States)

    Luketina, D.

    1998-01-01

    Simple tidal prism models for well-mixed estuaries have been in use for some time and are discussed in most text books on estuaries. The appeal of this model is its simplicity. However, there are several flaws in the logic behind the model. These flaws are pointed out and a more theoretically correct simple tidal prism model is derived. In doing so, it is made clear which effects can, in theory, be neglected and which can not.

  6. Performance Characteristics and Comparison of Abbott and artus Real-Time Systems for Hepatitis B Virus DNA Quantification ▿

    Science.gov (United States)

    Ismail, Ashrafali M.; Sivakumar, Jayashree; Anantharam, Raghavendran; Dayalan, Sujitha; Samuel, Prasanna; Fletcher, Gnanadurai J.; Gnanamony, Manu; Abraham, Priya

    2011-01-01

    Virological monitoring of hepatitis B virus (HBV) DNA is critical to the management of HBV infection. With several HBV DNA quantification assays available, it is important to use the most efficient testing system for virological monitoring. In this study, we evaluated the performance characteristics and comparability of three HBV DNA quantification systems: Abbott HBV real-time PCR (Abbott PCR), artus HBV real-time PCR with QIAamp DNA blood kit purification (artus-DB), and artus HBV real-time PCR with the QIAamp DSP virus kit purification (artus-DSP). The lower limits of detection of these systems were established against the WHO international standards for HBV DNA and were found to be 1.43, 82, and 9 IU/ml, respectively. The intra-assay and interassay coefficients of variation of plasma samples (1 to 6 log10 IU/ml) ranged between 0.05 to 8.34% and 0.16 to 3.48% for the Abbott PCR, 1.53 to 26.85% and 0.50 to 12.89% for artus-DB, and 0.29 to 7.42% and 0.94 to 3.01% for artus-DSP, respectively. Ninety HBV clinical samples were used for comparison of assays, and paired quantitative results showed strong correlation by linear regression analysis (artus-DB with Abbott PCR, r = 0.95; Abbott PCR with artus-DSP, r = 0.97; and artus-DSP with artus-DB, r = 0.94). Bland-Altman analysis showed a good level of agreement for Abbott PCR and artus-DSP, with a mean difference of 0.10 log10 IU/ml and limits of agreement of −0.91 to 1.11 log10 IU/ml. No genotype-specific bias was seen in all three systems for HBV genotypes A, C, and D, which are predominant in this region. This finding illustrates that the Abbott real-time HBV and artus-DSP systems show more comparable performance than the artus-DB system, meeting the current guidelines for assays to be used in the management of hepatitis B. PMID:21795507

  7. Detection of HBsAg and Anti HBc on donors of a blood bank by IRMA and ELISA methods

    International Nuclear Information System (INIS)

    Freire Martinez, D.Y.

    1985-10-01

    Comparative evaluation of two methods, Immunoradiometric Assay (IRMA) and Enzyme Immunoassay (ELISA), for detecting HBsAg and Anti HBc was made for determining which is the most advantageous and reliable. The study was made on 300 donors of the Hospital San Juan de Dios Blood Bank. In comparison with the reference method (IRMA), ELISA shows 91.67% of sensitivity. The Anti HBc detection by IRMA is more reliable than the HBsAg detection by IRMA and ELISA for determining the carrier state

  8. Targeting the unmet medical need: the Abbott Laboratories oncology approach.

    Science.gov (United States)

    Carlson, Dawn M; Steinberg, Joyce L; Gordon, Gary

    2005-09-01

    While significant advances in the treatment of cancer occured during the last half of the twentieth century, parallel decreases in overall cancer death rates were not observed. Cancer therapy remains an area of significant unmet medical need. Abbott's oncology research programs are focused on pioneering trageted, less toxic therapies, aimed at different aspects of tumor growth and development. Oncology drugs in development at Abbott target several mechanisms of cancer progression by interfering with multiple processes necessary for tumor growth: recruitment of a blood supply, cell proliferation, and the development of metastases. They include a selective endothelin A-receptor antagonist (atrasentan/Xinlay), 3 angiogenesis inhibitors (ABT 510, a thrombospondin mimetic: ABT-869, a multitargeted receptor tyrosine kinase inhibitor; and ABT 828, recombinant human plasminogen kringle 5), a cell proliferation inhibitor (ABT-751, an antimitotic agent), an apoptosis inducer (ABT 737, a Bcl-2 family inhibitor), and a poly(ADP-ribose)polymerase inhibitor.

  9. Prism-based single-camera system for stereo display

    Science.gov (United States)

    Zhao, Yue; Cui, Xiaoyu; Wang, Zhiguo; Chen, Hongsheng; Fan, Heyu; Wu, Teresa

    2016-06-01

    This paper combines the prism and single camera and puts forward a method of stereo imaging with low cost. First of all, according to the principle of geometrical optics, we can deduce the relationship between the prism single-camera system and dual-camera system, and according to the principle of binocular vision we can deduce the relationship between binoculars and dual camera. Thus we can establish the relationship between the prism single-camera system and binoculars and get the positional relation of prism, camera, and object with the best effect of stereo display. Finally, using the active shutter stereo glasses of NVIDIA Company, we can realize the three-dimensional (3-D) display of the object. The experimental results show that the proposed approach can make use of the prism single-camera system to simulate the various observation manners of eyes. The stereo imaging system, which is designed by the method proposed by this paper, can restore the 3-D shape of the object being photographed factually.

  10. Partnering for Preschool: A Study of Center Directors in New Jersey's Mixed-Delivery Abbott Program. Research Report

    Science.gov (United States)

    Whitebook, Marcy; Ryan, Sharon; Kipnis, Fran; Sakai, Laura

    2008-01-01

    In a series of New Jersey Supreme Court decisions known as Abbott v. Burke, the 28 (now 31) urban school districts serving the state's poorest students were ordered to create systems of high-quality preschool for all three- and four-year-old children, beginning in the 1999-2000 school year. The Abbott Preschool Program now serves approximately…

  11. Dotyophycus pacificum I. A. Abbott (Liagoraceae, Rhodophyta a new record for the Atlantic Ocean Dotyophycus pacificum Abbott (Liagoraceae, Rhodophyta nova referência para o oceano Atlântico

    Directory of Open Access Journals (Sweden)

    José Marcos de Castro Nunes

    2011-03-01

    Full Text Available Specimens of Dotyophycus pacificum I. A. Abbott were found during a survey of Rhodophyta on the coast of Bahia state. The samples were taken from 23-36 meters depth and the specimens found were studied in detail and compared to other morphologically similar species. This is the first time that the genus Dotyophycus is cited for the Atlantic Ocean.Durante estudo sobre as rodofíceas do litoral do estado da Bahia foram encontrados exemplares de Dotyophycus pacificum Abbott em coletas realizadas a 23-36 metros de profundidade. Os espécimes foram estudados detalhadamente e comparados a espécies morfologicamente semelhantes. Esta é a primeira ocorrência de D. pacificum para o oceano Atlântico.

  12. Evaluation of the Abbott realtime HCV genotype II RUO (GT II) assay with reference to 5'UTR, core and NS5B sequencing.

    Science.gov (United States)

    Mallory, Melanie A; Lucic, Danijela X; Sears, Mitchell T; Cloherty, Gavin A; Hillyard, David R

    2014-05-01

    HCV genotyping is a critical tool for guiding initiation of therapy and selecting the most appropriate treatment regimen. To evaluate the concordance between the Abbott GT II assay and genotyping by sequencing subregions of the HCV 5'UTR, core and NS5B. The Abbott assay was used to genotype 127 routine patient specimens and 35 patient specimens with unusual subtypes and mixed infection. Abbott results were compared to genotyping by 5'UTR, core and NS5B sequencing. Sequences were genotyped using the NCBI non-redundant database and the online genotyping tool COMET. Among routine specimens, core/NS5B sequencing identified 93 genotype 1s, 13 genotype 2s, 15 genotype 3s, three genotype 4s, two genotype 6s and one recombinant specimen. Genotype calls by 5'UTR, core, NS5B sequencing and the Abbott assay were 97.6% concordant. Core/NS5B sequencing identified two discrepant samples as genotype 6 (subtypes 6l and 6u) while Abbott and 5'UTR sequencing identified these samples as genotype 1 with no subtype. The Abbott assay subtyped 91.4% of genotype 1 specimens. Among the 35 rare specimens, the Abbott assay inaccurately genotyped 3k, 6e, 6o, 6q and one genotype 4 variant; gave indeterminate results for 3g, 3h, 4r, 6m, 6n, and 6q specimens; and agreed with core/NS5B sequencing for mixed specimens. The Abbott assay is an automated HCV genotyping method with improved accuracy over 5'UTR sequencing. Samples identified by the Abbott assay as genotype 1 with no subtype may be rare subtypes of other genotypes and thus require confirmation by another method. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Estudo da soroprevalência do AgHBs em gestantes da 15ª Regional de Saúde e da imunoprofilaxia para os recém-nascidos das gestantes AgHBs positivo - DOI: 10.4025/actascihealthsci.v30i1.4394 Study into the HBsAg seroprevalence in pregnant women from the 15th Health Regional and the immunoprophylaxia on the newborns of these HBsAg-positive women - DOI: 10.4025/actascihealthsci.v30i1.4394

    Directory of Open Access Journals (Sweden)

    Dennis Armando Bertolini

    2008-07-01

    Full Text Available Determinar a prevalência do AgHBs nas gestantes da 15ª Regional de Saúde (15ª R.S. atendidas no Laboratório de Ensino e Pesquisa em Análises Clínicas (Lepac, Universidade Estadual de Maringá, e verificar se foi solicitada a imunoprofilaxia para hepatite B aos recém-natos das gestantes AgHBs positivo, no período de janeiro de 1998 a dezembro de 2002. A pesquisa do AgHBs foi realizada pela técnica imunoenzimática IMxHBsAg e Axsym HBsAg (Laboratório Abbott. As solicitações de imunobiológicos especiais para a imunoprofilaxia da hepatite B ao CRIE foram obtidas na Seção de Epidemiologia da 15ª R.S. Foram analisadas 12.274 gestantes e a prevalência do AgHBs foi de 1,0%. Dentre as 125 gestantes AgHBs positivo, foram solicitadas imunoprofilaxia para 32 (25,6% recém-nascidos. Ainda que a prevalência encontrada indique ser esta uma área de baixa endemicidade, os resultados reafirmam a importância da realização do diagnóstico da hepatite B no atendimento pré-natal, para adoção da imunoprofilaxia no recém-nascido.To determine HBsAg prevalence among pregnant women from the 15th Health Regional assisted in the Laboratório de Ensino e Pesquisa em Análises Clínicas (Lepac, Universidade Estadual de Maringá, and verify whether immunoprophylaxis with vaccine and immunoglobulin was requested for the newborns of HBsAg-positive women during the period from January 1998 to December 2002. The research about HBsAg was conducted using the immunoenzymatic IMxHBsAg (Abbot Lab and Axsym HBsAg (Abbot Lab techniques. The requests to the CRIE for special immunobiologic agents for Hepatitis B immunoprophylaxis were obtained in the Department of Epidemiology from the 15th Health Regional. The analysis includes 12,274 pregnant women, and the HBsAg prevalence was 1.0%. Among 125 HBsAg positive pregnant women, immunoprophylaxis was requested for 32 (25.6% newborns. Although the prevalence detected demonstrates this to be a low endemic area, the

  14. A controllable spin prism

    International Nuclear Information System (INIS)

    Hakioglu, T

    2009-01-01

    Based on Khodas et al (2004 Phys. Rev. Lett. 92 086602), we propose a device acting like a controllable prism for an incident spin. The device is a large quantum well where Rashba and Dresselhaus spin-orbit interactions are present and controlled by the plunger gate potential, the electric field and the barrier height. A totally destructive interference can be manipulated externally between the Rashba and Dresselhaus couplings. The spin-dependent transmission/reflection amplitudes are calculated as the control parameters are changed. The device operates as a spin prism/converter/filter in different regimes and may stimulate research in promising directions in spintronics in analogy with linear optics.

  15. Antigens of hepatitis B virus: failure to detect HBeAg on the surfaces of HBsAg forms

    Energy Technology Data Exchange (ETDEWEB)

    Gerin, J L [Oak Ridge National Lab., Rockville, MD; Shih, J W.K.; McAuliffee, V J; Purcell, R H

    1978-01-01

    The particulate forms of HBsAg were analysed for the presence of HBeAG on their surfaces. By immunodiffusion analysis, anti-HBe did not form precipitin bands with the purified forms of HBsAg and hyperimmune guinea pig antisera to these forms did not react with HBeAg. Lines of non-identity were observed between the HBeAg determinants (e/sub 1/ and e/sub 2/) and the Dane particles and filaments isolated from an HBeAg-positive serum. Finally, anti-HBe failed to precipitate the polymerase-positive subpopulation of Dane particles, indicating that anti-HBe has no direct role in virus neutralization.

  16. Fulfilling the Promise of Abbott: The Lighthouse Assessment Process--Improving Programs through Measured Outcomes. Policy Progress, Spring 2004

    Science.gov (United States)

    Association for Children of New Jersey, 2004

    2004-01-01

    In an attempt to better prepare young children for the challenges of kindergarten and first grade, the Supreme Court of New Jersey, in its 1998 landmark decision of "Abbott v. Burke" (Abbott V), required the State's poorest school districts to implement high quality, intensive preschool for all 3-and 4-year old children. To take…

  17. Plant Reliability - an Integrated System for Management (PR-ISM)

    International Nuclear Information System (INIS)

    Aukeman, M.C.; Leininger, E.G.; Carr, P.

    1984-01-01

    The Toledo Edison Company, located in Toledo, Ohio, United States of America, recently implemented a comprehensive maintenance management information system for the Davis-Besse Nuclear Power Station. The system is called PR-ISM, meaning Plant Reliability - An Integrated System for Management. PR-ISM provides the tools needed by station management to effectively plan and control maintenance and other plant activities. The PR-ISM system as it exists today consists of four integrated computer applications: equipment data base maintenance, maintenance work order control, administrative activity tracking, and technical specification compliance. PR-ISM is designed as an integrated on-line system and incorporates strong human factors features. PR-ISM provides each responsible person information to do his job on a daily basis and to look ahead towards future events. It goes beyond 'after the fact' reporting. In this respect, PR-ISM is an 'interactive' control system which: captures work requirements and commitments as they are identified, provides accurate and up-to-date status immediately to those who need it, simplifies paperwork and reduces the associated time delays, provides the information base for work management and reliability analysis, and improves productivity by replacing clerical tasks and consolidating maintenance activities. The functional and technical features of PR-ISM, the experience of Toledo Edison during the first year of operation, and the factors which led to the success of the development project are highlighted. (author)

  18. The Instructional Guide for Abbott Skills Enhancement Classes. Revised Edition.

    Science.gov (United States)

    Ballinger, Ronda; Gee, Mary Kay

    This guide, which integrates adult basic education (ABE) curriculum, job skills for Abbott Laboratories, and work-related foundation skills, is designed for an instructional program in the skill areas of reading, writing, oral communications, mathematics, and problem solving. In addition to creating a uniform process and product to promote…

  19. Salt-induced square prism Pd microtubes and their ethanol electrocatalysis properties

    International Nuclear Information System (INIS)

    Jiang, Kunpeng; Ma, Shenghua; Wang, Yinan; Zhang, Ying; Han, Xiaojun

    2017-01-01

    Highlights: • A simple method is established to fabricate square prism Pd microtubes. • The novel square prism Pd microtubes are based on a salt-induced aggregation event. • The surface of the square prism tubes convert from cataphracted nanosheets to spheres after calcinations treatment. • The square prism pure Pd tubes show excellent electro catalytic activity towards ethanol oxidation. - Abstract: The synthesis of square prism tubes are always challenging due to their thermo and dynamical instability. We demonstrated a simple method using Pd"2"+ doped PoPD oligomers as building blocks to assemble into 1D square prism metal-organic microtubes, which consists of cataphracted nanosheets on the surfaces. After high temperature treatment, the microtubes became square prism Pd tubes with a cross section size of 3 μm. The pure Pd microtubes showed excellent catalyzing activity towards the electro oxidation of ethanol. Their electrochemically active surface area is 48.2 m"2 g"−"1, which indicates the square prism Pd tubes have great potential in the field of fuel cell.

  20. Salt-induced square prism Pd microtubes and their ethanol electrocatalysis properties

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Kunpeng; Ma, Shenghua; Wang, Yinan; Zhang, Ying; Han, Xiaojun, E-mail: hanxiaojun@hit.edu.cn

    2017-05-01

    Highlights: • A simple method is established to fabricate square prism Pd microtubes. • The novel square prism Pd microtubes are based on a salt-induced aggregation event. • The surface of the square prism tubes convert from cataphracted nanosheets to spheres after calcinations treatment. • The square prism pure Pd tubes show excellent electro catalytic activity towards ethanol oxidation. - Abstract: The synthesis of square prism tubes are always challenging due to their thermo and dynamical instability. We demonstrated a simple method using Pd{sup 2+} doped PoPD oligomers as building blocks to assemble into 1D square prism metal-organic microtubes, which consists of cataphracted nanosheets on the surfaces. After high temperature treatment, the microtubes became square prism Pd tubes with a cross section size of 3 μm. The pure Pd microtubes showed excellent catalyzing activity towards the electro oxidation of ethanol. Their electrochemically active surface area is 48.2 m{sup 2} g{sup −1}, which indicates the square prism Pd tubes have great potential in the field of fuel cell.

  1. Neutron forward diffraction by single crystal prisms

    Indian Academy of Sciences (India)

    We have derived analytic expressions for the deflection as well as transmitted fraction of monochromatic neutrons forward diffracted by a single crystal prism. In the vicinity of a Bragg reflection, the neutron deflection deviates sharply from that for an amorphous prism, exhibiting three orders of magnitude greater sensitivity to ...

  2. Boolean Operations with Prism Algebraic Patches

    Science.gov (United States)

    Bajaj, Chandrajit; Paoluzzi, Alberto; Portuesi, Simone; Lei, Na; Zhao, Wenqi

    2009-01-01

    In this paper we discuss a symbolic-numeric algorithm for Boolean operations, closed in the algebra of curved polyhedra whose boundary is triangulated with algebraic patches (A-patches). This approach uses a linear polyhedron as a first approximation of both the arguments and the result. On each triangle of a boundary representation of such linear approximation, a piecewise cubic algebraic interpolant is built, using a C1-continuous prism algebraic patch (prism A-patch) that interpolates the three triangle vertices, with given normal vectors. The boundary representation only stores the vertices of the initial triangulation and their external vertex normals. In order to represent also flat and/or sharp local features, the corresponding normal-per-face and/or normal-per-edge may be also given, respectively. The topology is described by storing, for each curved triangle, the two triples of pointers to incident vertices and to adjacent triangles. For each triangle, a scaffolding prism is built, produced by its extreme vertices and normals, which provides a containment volume for the curved interpolating A-patch. When looking for the result of a regularized Boolean operation, the 0-set of a tri-variate polynomial within each such prism is generated, and intersected with the analogous 0-sets of the other curved polyhedron, when two prisms have non-empty intersection. The intersection curves of the boundaries are traced and used to decompose each boundary into the 3 standard classes of subpatches, denoted in, out and on. While tracing the intersection curves, the locally refined triangulation of intersecting patches is produced, and added to the boundary representation. PMID:21516262

  3. The response to prism deviations in human infants.

    Science.gov (United States)

    Riddell, P M; Horwood, A M; Houston, S M; Turner, J E

    1999-09-23

    Previous research has suggested that infants are unable to make a corrective eye movement in response to a small base-out prism placed in front of one eye before 14-16 weeks [1]. Three hypotheses have been proposed to explain this early inability, and each of these makes different predictions for the time of onset of a response to a larger prism. The first proposes that infants have a 'degraded sensory capacity' and so require a larger retinal disparity (difference in the position of the image on the retina of each eye) to stimulate disparity detectors [2]. This predicts that infants might respond at an earlier age than previously reported [1] when tested using a larger prism. The second hypothesis proposes that infants learn to respond to larger retinal disparities through practice with small disparities [3]. According to this theory, using a larger prism will not result in developmentally earlier responses, and may even delay the response. The third hypothesis proposes that the ability to respond to prismatic deviation depends on maturational factors indicated by the onset of stereopsis (the ability to detect depth in an image on the basis of retinal disparity cues only) [4] [5], predicting that the size of the prism is irrelevant. To differentiate between these hypotheses, we tested 192 infants ranging from 2 to 52 weeks of age using a larger prism. Results showed that 63% of infants of 5-8 weeks of age produced a corrective eye movement in response to placement of a prism in front of the eye when in the dark. Both the percentage of infants who produced a response, and the speed of the response, increased with age. These results suggest that infants can make corrective eye movements in response to large prismatic deviations before 14-16 weeks of age. This, in combination with other recent results [6], discounts previous hypotheses.

  4. A PILOT EXTERNAL QUALITY ASSURANCE STUDY OF TRANSFUSION SCREENING FOR HIV, HCV AND HBSAG IN TWELVE AFRICAN COUNTRIES

    Science.gov (United States)

    Bloch, Evan M; Shah, Avani; Kaidarova, Zhanna; Laperche, Syria; Lefrere, Jean-Jacques; van Hasselt, James; Zacharias, Peter; Murphy, Edward L

    2014-01-01

    Background and Objectives Serologic screening for the major transfusion transmissible viruses (TTV) is critical to blood safety and has been widely implemented. However, actual performance as measured by proficiency testing has not been well studied in Sub-Saharan Africa. Therefore, we conducted an external quality assessment of laboratories engaged in transfusion screening in the region. Materials and Methods Blinded test panels, each comprising 25 serum samples that were pedigreed for HIV, HBsAg, HCV and negative status, were sent to participating laboratories. The panels were tested using the laboratories’ routine donor screening methods and conditions. Sensitivity and specificity were calculated and multivariable analysis was used to compare performance against mode of testing, country and infrastructure. Results A total of 12 African countries and 44 laboratories participated in the study. The mean (range) sensitivities for HIV, HBsAg and HCV were 91.9% (14.3-100), 86.7% (42.9-100) and 90.1% (50-100), respectively. Mean specificities for HIV, HBsAg and HCV were 97.7%, 97% and 99.5% respectively. After adjusting for country and infrastructure, rapid tests had significantly lower sensitivity than enzyme immunoassays (EIA) for both HBsAg (p<0.0001) and HCV (p<0.05). Sensitivity also varied by country and selected infrastructure variables. Conclusion While specificity was high, sensitivity was more variable and deficient in a substantial number of testing laboratories. These findings underscore the importance of proficiency testing and quality control, particularly in Africa where TTV prevalence is high. PMID:25052195

  5. Containment performance of S-prism under severe BDB conditions

    International Nuclear Information System (INIS)

    Boardman, C.E.; Dubberley, A.E.; Hui, M.; Iwashige, K.

    2001-01-01

    S-PRISM is an advanced Fast Reactor plant design that utilizes compact modular pool-type reactors sized to enable factory fabrication and an affordable prototype test of a single Nuclear Steam Supply System (NSSS) for design certification at minimum cost and risk. Based on the success of the previous DOE sponsored Advanced Liquid Metal Reactor (ALMR) program GE has continued to develop and assess the technical viability and economic potential of an up-rated modular Fast Reactor called Super PRISM (S-PRISM). S-PRISM retains all of the key ALMR design features including passive reactor shutdown, passive shutdown heat removal, and passive reactor cavity cooling that were developed under an earlier DOE program. An additional feature of S-PRISM involves the use an innovative containment system that reduces the required design basis containment pressure by a factor of two through the use of a controlled venting system. The performance of this innovative containment system is evaluated and described in this paper. (author)

  6. Evaluation of the clinical performance of the Abbott RealTime High-Risk HPV for carcinogenic HPV detection.

    Science.gov (United States)

    Halfon, Philippe; Benmoura, Dominique; Agostini, Aubert; Khiri, Hacene; Penaranda, Guillaume; Martineau, Agnes; Blanc, Bernard

    2010-08-01

    Abbott RealTime (RT) High-Risk (HR) HPV assay is a new qualitative real-time polymerase chain reaction (PCR) based assay for the detection of 14 HR HPV DNA. The assay can differentiate between the infection by HPV 16, HPV 18 and non-HPV 16/18 types through the distinct fluorescent labels on the type specific probes. To evaluate the clinical performance of the Abbott RT HR HPV test, in comparison with biopsy, Hybrid Capture II (HCII), and Linear Array (LA), for detection of high-grade disease (CIN2+). The study population consisted of 143 women who were included in three referral gynecology clinics in Marseilles (France) between March 2007 and June 2008. The clinical performance of the RT HR HPV assay, performed on the fully automated m2000 system, was compared with HCII and LA. HR HPV positivity rate was similar for all tests (Abbott RT HR HPV and HCII, 62%, and LA 63%). All tests had high sensitivities and negative predictive values for CIN2+ detection (>90%). The agreement between HCII and Abbott RT HR HPV, and between HCII and LA were 93% (k=0.85) and 96% (k=0.91) respectively. As expected, HPV16 or HPV18 positivity was greater in advanced grades of disease, especially in CIN2+ patients: 85% in CIN2+ vs. 33% in Abbott RT HR HPV assay is good and closely correlated with the two other assays. The automation and ability to identify type 16 and 18 make this a very attractive option for HPV testing in laboratories and potentially provides improved patient management. Copyright 2010. Published by Elsevier B.V.

  7. PRISMES. The INES microgrid platform

    Energy Technology Data Exchange (ETDEWEB)

    Barruel, F.; Vervaart, M.; Merten, J. [INES, 73 - Le Bourget-du-lac (FR). Lab. for Solar Systems (L2S)

    2010-07-01

    The massive penetration of fluctuating renewable energies will challenge the low voltage grids. Innovative solutions to address this issue need to be developed and tested. They may consist of intelligent energy management systems and the use of storage systems. For this purpose the PRISMES platform has been designed and implemented at the INES headquarter in Chambery. It is a universal test and development tool, such as stand alone hybrid systems and grid connected PV systems combined with a storage system and loads. This paper describes the PRISMES facility which will start operation in autumn 2008. (orig.)

  8. Accuracy assessment of ALOS optical instruments: PRISM and AVNIR-2

    Science.gov (United States)

    Tadono, Takeo; Shimada, Masanobu; Iwata, Takanori; Takaku, Junichi; Kawamoto, Sachi

    2017-11-01

    This paper describes the updated results of calibration and validation to assess the accuracies for optical instruments onboard the Advanced Land Observing Satellite (ALOS, nicknamed "Daichi"), which was successfully launched on January 24th, 2006 and it is continuously operating very well. ALOS has an L-band Synthetic Aperture Radar called PALSAR and two optical instruments i.e. the Panchromatic Remotesensing Instrument for Stereo Mapping (PRISM) and the Advanced Visible and Near Infrared Radiometer type-2 (AVNIR-2). PRISM consists of three radiometers and is used to derive a digital surface model (DSM) with high spatial resolution that is an objective of the ALOS mission. Therefore, geometric calibration is important in generating a precise DSM with stereo pair images of PRISM. AVNIR-2 has four radiometric bands from blue to near infrared and uses for regional environment and disaster monitoring etc. The radiometric calibration and image quality evaluation are also important for AVNIR-2 as well as PRISM. This paper describes updated results of geometric calibration including geolocation determination accuracy evaluations of PRISM and AVNIR-2, image quality evaluation of PRISM, and validation of generated PRISM DSM. These works will be done during the ALOS mission life as an operational calibration to keep absolute accuracies of the standard products.

  9. Traceability Assessment and Performance Evaluation of Results for Measurement of Abbott Clinical Chemistry Assays on 4 Chemistry Analyzers.

    Science.gov (United States)

    Lim, Jinsook; Song, Kyung Eun; Song, Sang Hoon; Choi, Hyun-Jung; Koo, Sun Hoe; Kwon, Gye Choel

    2016-05-01

    -The traceability of clinical results to internationally recognized and accepted reference materials and reference measurement procedures has become increasingly important. Therefore, the establishment of traceability has become a mandatory requirement for all in vitro diagnostics devices. -To evaluate the traceability of the Abbott Architect c8000 system (Abbott Laboratories, Abbott Park, Illinois), consisting of calibrators and reagents, across 4 different chemistry analyzers, and to evaluate its general performance on the Toshiba 2000FR NEO (Toshiba Medical Systems Corporation, Otawara-shi, Tochigi-ken, Japan). -For assessment of traceability, secondary reference materials were evaluated 5 times, and then bias was calculated. Precision, linearity, and carryover were determined according to the guidelines of the Clinical and Laboratory Standards Institute (Wayne, Pennsylvania). -The biases from 4 different analyzers ranged from -2.33% to 2.70% on the Toshiba 2000FR NEO, -2.33% to 5.12% on the Roche Hitachi 7600 (Roche Diagnostics International, Basel, Switzerland), -0.93% to 2.87% on the Roche Modular, and -2.16% to 2.86% on the Abbott Architect c16000. The total coefficients of variance of all analytes were less than 5%. The coefficients of determination (R(2)) were more than 0.9900. The carryover rate ranged from -0.54% to 0.17%. -Abbott clinical chemistry assays met the performance criteria based on desirable biological variation for precision, bias, and total error. They also showed excellent linearity and carryover. Therefore, these clinical chemistry assays were found to be accurate and reliable and are readily applicable on the various platforms used in this study.

  10. Characteristics of Fluid Force Reduction for Two Different Square Prisms in a Tandem Arrangement

    Energy Technology Data Exchange (ETDEWEB)

    Ro, Ki Deok; Kang, Chang Whan; Park, Kwon Ho [Gyeongsang Nat’l Univ., Jinju (Korea, Republic of)

    2017-07-15

    The Characteristics of the flow fields of a square prism having a small square prism were investigated by measuring of lift and drag on the square prism and visualizing the flow field using PIV. The experimental parameters were the width ratios(H/B=0.2~0.6) of small square prisms to the prism width and the gap ratios (G/B=0~3) between the prism and the small square prism. The drag reduction rate of the square prism initially increased and then decreased with the G/B ratio for the same H/B ratio, and increased with the H/B ratio for the same G/B ratio. The maximum drag reduction rate of 98.0% was observed at H/B=0.6 and G/B=1.0. The lift reduction rate of the square prism was not affected by the width and gap ratios; the total average value was approximately 66.5%. In case of a square prism having a small square prism, the stagnation regions were represented in the upstream and downstream sides of the square prism.

  11. The Labour Process of Teaching at John Abbott College (Part One).

    Science.gov (United States)

    Johnson, Walter

    This survey was conducted at John Abbott College to gauge teachers' responses to issues concerning their job satisfaction, interaction with colleagues, perceptions of student abilities, and perceptions concerning union negotiating priorities and areas of conflict within the institutional environment. Of the 75 teachers contacted, 47 returned…

  12. Negative index effects from a homogeneous positive index prism

    Science.gov (United States)

    Marcus, Sherman W.; Epstein, Ariel

    2017-12-01

    Cellular structured negative index metamaterials in the form of a right triangular prism have often been tested by observing the refraction of a beam across the prism hypotenuse which is serrated in order to conform to the cell walls. We show that not only can this negative index effect be obtained from a homogeneous dielectric prism having a positive index of refraction, but in addition, for sampling at the walls of the cellular structure, the phase in the material has the illusory appearance of moving in a negative direction. Although many previous reports relied on refraction direction and phase velocity of prism structures to verify negative index design, our investigation indicates that to unambiguously demonstrate material negativity additional empirical evidence is required.

  13. Liver Rapid Reference Set Application: Hemken - Abbott (2015) — EDRN Public Portal

    Science.gov (United States)

    The aim for this testing is to find a small panel of biomarkers (n=2-5) that can be tested on the Abbott ARCHITECT automated immunoassay platform for the early detection of hepatocellular carcinoma (HCC). This panel of biomarkers should perform significantly better than alpha-fetoprotein (AFP) alone based on multivariate statistical analysis. This testing of the EDRN reference set will help expedite the selection of a small panel of ARCHITECT biomarkers for the early detection of HCC. The panel of ARCHITECT biomarkers Abbott plans to test include: AFP, protein induced by vitamin K absence or antagonist-II (PIVKA-II), golgi protein 73 (GP73), hepatocellular growth factor (HGF), dipeptidyl peptidase 4 (DPP4) and DPP4/seprase (surface expressed protease) heterodimer hybrid. PIVKA-II is abnormal des-carboxylated prothrombin (DCP) present in vitamin K deficiency.

  14. The Program for Regional and International Shorebird Monitoring (PRISM)

    Science.gov (United States)

    Bart, J.; Andres, B.; Brown, S.; Donaldson, G.; Harrington, B.; Johnston, V.; Jones, S.; Morrison, R.I.G.; Skagen, S.K.

    2005-01-01

    This report describes the "Program for Regional and International Shorebird Monitoring" (PRISM). PRISM is being implemented by a Canada-United States Shorebird Monitoring and Assessment Committee formed in 2001 by the Canadian Shorebird Working Group and the U.S. Shorebird Council. PRISM provides a single blueprint for implementing the shorebird conservation plans recently completed in Canada and the United States. The goals of PRISM are to (1) estimate the size of breeding population of 74 shorebird taxa in North America; (2) describe the distribution, abundance, and habitat relationships for each of these taxa; (3) monitor trends in shorebird population size; (4) monitor shorebird numbers at stopover locations, and; (5) assist local managers in meeting their shorebird conservation goals. PRISM has four main components: arctic and boreal breeding surveys, temperate breeding surveys, temperate non-breeding surveys, and neotropical surveys. Progress on, and action items for, each major component are described. The more important major tasks for immediate action are carrying out the northern surveys, conducting regional analyses to design the program of migration counts, and evaluating aerial photographic surveys for migration and winter counts.

  15. Recognizing Variable Environments The Theory of Cognitive Prism

    CERN Document Server

    Dong, Tiansi

    2012-01-01

    Normal adults do not have any difficulty in recognizing their homes. But can artificial systems do in the same way as humans? This book collects interdisciplinary evidences and presents an answer from the perspective of computing, namely, the theory of cognitive prism. To recognize an environment, an intelligent system only needs to classify objects, structures them based on the connection relation (not through measuring!), subjectively orders the objects, and compares with the target environment, whose knowledge is similarly structured. The intelligent system works, therefore, like a prism: when a beam of light (a scene) reaches (is perceived) to an optical prism (by an intelligent system), some light (objects) is reflected (are neglected), those passed through (the recognized objects) are distorted (are ordered differently). So comes the term 'cognitive prism'! Two fundamental propositions used in the theory can be informally stated as follow: an orientation relation is a kind of distance comparison relatio...

  16. A Clinical study of HBsAg and Anti-HBs in the serum of patients with various liver diseases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hak San; Kim, Jong Mann; Kim, Hwa Sook; Kim, Yul Ja; Lee, Hak Choong; Lee, Chong Suk [National Medical Center, Seoul (Korea, Republic of)

    1981-09-15

    Serum HBsAg and Anti-HBs obtained by radioimmunoassay were studied in 109 cases of various liver diseases who visited or were admitted to National Medical Center from December, 1980 to July, 1981. The results were as follows; 1) HBsAg was detected in 67.0% of total 109 cases; 71.9% of 32 cases with acute viral hepatitis, 71.4% of 14 cases with chronic hepatitis, 65.2% of 46 cases with liver cirrhosis and 58.8% of 17 cases with hepatoma. 2) Anti-HBs was detected in 32.1% of total 109 cases; 37.0% of 46 cases with liver cirrhosis, 29.4% of 17 cases with hepatoma, 28.6% of 14 cases with chronic hepatitis, 28.1% of 32 cases with acute viral hepatitis. 3) HBsAg or Anti-HBs, the markers of Hepatitis B virus was detected in 89.0% of total 109 cases; 93.6% of 32 cases with acute viral hepatitis, 89.1% of 46 cases with liver cirrhosis, 85.7% of 14 cases with chronic hepatitis and 82.4% of 17 cases with hepatoma, which strongly suggested that the various liver diseases were associated with hepatitis B virus infection.

  17. A Clinical study of HBsAg and Anti-HBs in the serum of patients with various liver diseases

    International Nuclear Information System (INIS)

    Kim, Hak San; Kim, Jong Mann; Kim, Hwa Sook; Kim, Yul Ja; Lee, Hak Choong; Lee, Chong Suk

    1981-01-01

    Serum HBsAg and Anti-HBs obtained by radioimmunoassay were studied in 109 cases of various liver diseases who visited or were admitted to National Medical Center from December, 1980 to July, 1981. The results were as follows; 1) HBsAg was detected in 67.0% of total 109 cases; 71.9% of 32 cases with acute viral hepatitis, 71.4% of 14 cases with chronic hepatitis, 65.2% of 46 cases with liver cirrhosis and 58.8% of 17 cases with hepatoma. 2) Anti-HBs was detected in 32.1% of total 109 cases; 37.0% of 46 cases with liver cirrhosis, 29.4% of 17 cases with hepatoma, 28.6% of 14 cases with chronic hepatitis, 28.1% of 32 cases with acute viral hepatitis. 3) HBsAg or Anti-HBs, the markers of Hepatitis B virus was detected in 89.0% of total 109 cases; 93.6% of 32 cases with acute viral hepatitis, 89.1% of 46 cases with liver cirrhosis, 85.7% of 14 cases with chronic hepatitis and 82.4% of 17 cases with hepatoma, which strongly suggested that the various liver diseases were associated with hepatitis B virus infection.

  18. Higher baseline viral diversity correlates with lower HBsAg decline following PEGylated interferon-alpha therapy in patients with HBeAg-positive chronic hepatitis B.

    Science.gov (United States)

    Li, Hu; Zhang, Li; Ren, Hong; Hu, Peng

    2018-01-01

    Viral diversity seems to predict treatment outcomes in certain viral infections. The aim of this study was to evaluate the association between baseline intra-patient viral diversity and hepatitis B surface antigen (HBsAg) decline following PEGylated interferon-alpha (Peg-IFN-α) therapy. Twenty-six HBeAg-positive patients who were treated with Peg-IFN-α were enrolled. Nested polymerase chain reaction (PCR), cloning, and sequencing of the hepatitis B virus S gene were performed on baseline samples, and normalized Shannon entropy (Sn) was calculated as a measure of small hepatitis B surface protein (SHBs) diversity. Multiple regression analysis was used to estimate the association between baseline Sn and HBsAg decline. Of the 26 patients enrolled in the study, 65.4% were male and 61.5% were infected with hepatitis B virus genotype B. The median HBsAg level at baseline was 4.5 log 10 IU/mL (interquartile range: 4.1-4.9) and declined to 3.0 log 10 IU/mL (interquartile range: 1.7-3.9) after 48 weeks of Peg-IFN-α treatment. In models adjusted for baseline alanine aminotransferase (ALT) and HBsAg, the adjusted coefficients (95% CI) for ΔHBsAg and relative percentage HBsAg decrease were -1.3 (-2.5, -0.2) log 10 IU/mL for higher SHBs diversity (Sn≥0.58) patients and -26.4% (-50.2%, -2.5%) for lower diversity (Sndiversity. Baseline intra-patient SHBs diversity was inverse to HBsAg decline in HBeAg-positive chronic hepatitis B (CHB) patients receiving Peg-IFN-α monotherapy. Also, more sequence variations within the "a" determinant upstream flanking region and the first loop of the "a" determinant were the main sources of the higher SHBs diversity.

  19. Asymmetric transmission in prisms using structures and materials with isotropic-type dispersion.

    Science.gov (United States)

    Gundogdu, Funda Tamara; Serebryannikov, Andriy E; Cakmak, A Ozgur; Ozbay, Ekmel

    2015-09-21

    It is demonstrated that strong asymmetry in transmission can be obtained at the Gaussian beam illumination for a single prism based on a photonic crystal (PhC) with isotropic-type dispersion, as well as for its analog made of a homogeneous material. Asymmetric transmission can be realized with the aid of refraction at a proper orientation of the interfaces and wedges of the prism, whereas neither contribution of higher diffraction orders nor anisotropic-type dispersion is required. Furthermore, incidence toward a prism wedge can be used for one of two opposite directions in order to obtain asymmetry. Thus, asymmetric transmission is a general property of the prism configurations, which can be obtained by using simple geometries and quite conventional materials. The obtained results show that strong asymmetry can be achieved in PhC prisms with (nearly) circular shape of equifrequency dispersion contours, in both cases associated with the index of refraction 01. For the comparison purposes, results are also presented for solid uniform non-magnetic prisms made of a material with the same value of n. It is shown in zero-loss approximation that the PhC prism and the ultralow-index material prism (01. Possible contributions of scattering on the individual rods and diffraction on the wedge to the resulting mechanism are discussed. Analogs of unidirectional splitting and unidirectional deflection regimes, which are known from the studies of PhC gratings, are obtained in PhC prisms and solid uniform prisms, i.e. without higher diffraction orders.

  20. Factors Predicting HBsAg Seroclearance and Alanine Transaminase Elevation in HBeAg-Negative Hepatitis B Virus-Infected Patients with Persistently Normal Liver Function.

    Directory of Open Access Journals (Sweden)

    Tai-Long Chien

    Full Text Available A certain proportion of hepatitis B virus (HBV-infected patients with persistently normal alanine transaminase (ALT levels have significant fibrosis. Using liver stiffness measurements (Fibroscan® and laboratory data, including serum ALT, quantitative HBsAg (qHBsAg, and HBV DNA, we attempted to predict the natural histories of these patients.Non-cirrhotic HBeAg-negative chronic hepatitis B patients with persistently normal ALT were followed up prospectively with the end points of HBsAg seroclearance and ALT elevation above the upper limit of normal. The factors that were predictive of the end points were identified.A total of 235 patients with an average age of 48.1 +/- 10.7 years were followed up for 7 years. Eight patients (3.4% lost HBsAg, and 15 patients (6.4% experienced ALT elevation. The overall cumulative HBsAg seroclearances were 0.4%, 1.3% and 2.3% at years 1, 3 and 5, respectively. Regarding HBsAg seroclearance, the qHBsAg (< 30 IU/ml cutoff resulted in a hazard ratio (HR of 19.6 with a 95% confidence interval (CI of 2.2-166.7 (P = 0.008. The baseline ALT level (odd ratio (OR 1.075, 95% CI 1.020-1.132, P = 0.006 and a qHBsAg above 1000 IU/ml (3.7, 1.1-12.4, P = 0.032 were associated with ALT elevation. Limited to men, the baseline liver stiffness (1.6, 1.0-2.5, P = 0.031 and a qHBsAg above 1000 IU/ml (10.4, 2.1-52.4, P = 0.004 were factors that were independently associated with ALT elevation.A low qHBsAg level predicted HBsAg clearance. Baseline ALT and a qHBsAg above 1000 IU/ml were independent predictive factors for ALT elevation. Among the men, the independent predictive factors for ALT elevation were qHBsAg and liver stiffness.

  1. Abbott prism: a multichannel heterogeneous chemiluminescence immunoassay analyzer.

    Science.gov (United States)

    Khalil, O S; Zurek, T F; Tryba, J; Hanna, C F; Hollar, R; Pepe, C; Genger, K; Brentz, C; Murphy, B; Abunimeh, N

    1991-09-01

    We describe a multichannel heterogeneous immunoassay analyzer in which a sample is split between disposable reaction trays in a group of linear tracks. The system's pipettor uses noninvasive sensing of the sample volume and disposable pipet tips. Each assay track has (a) a conveyor belt for moving reaction trays to predetermined functional stations, (b) temperature-controlled tunnels, (c) noncontact transfer of the reaction mixture between incubation and detection wells, and (d) single-photon counting to detect a chemiluminescence (CL) signal from the captured immunochemical product. A novel disposable reaction tray, with separate reaction and detection wells and self-contained fluid removal, is used in conjunction with the transfer device on the track to produce a carryover-free system. The linear immunoassay track has nine predetermined positions for performing individual assay steps. Assay step sequence and timing is selected by changing the location of the assay modules between these predetermined positions. The assay methodology, a combination of microparticle capture and direct detection of a CL signal on a porous matrix, offers excellent sensitivity, specificity, and ease of automation. Immunoassay configurations have been tested for hepatitis B surface antigen and for antibodies to hepatitis B core antigen, hepatitis C virus, human immunodeficiency virus I and II, and human T-cell leukemia virus I and II.

  2. Construction of a hepatitis B virus neutralizing chimeric monoclonal antibody recognizing escape mutants of the viral surface antigen (HBsAg).

    Science.gov (United States)

    Golsaz-Shirazi, Forough; Amiri, Mohammad Mehdi; Farid, Samira; Bahadori, Motahareh; Bohne, Felix; Altstetter, Sebastian; Wolff, Lisa; Kazemi, Tohid; Khoshnoodi, Jalal; Hojjat-Farsangi, Mohammad; Chudy, Michael; Jeddi-Tehrani, Mahmood; Protzer, Ulrike; Shokri, Fazel

    2017-08-01

    Hepatitis B virus (HBV) infection is a global burden on the health-care system and is considered as the tenth leading cause of death in the world. Over 248 million patients are currently suffering from chronic HBV infection worldwide and annual mortality rate of this infection is 686000. The "a" determinant is a hydrophilic region present in all antigenic subtypes of hepatitis B surface antigen (HBsAg), and antibodies against this region can neutralize the virus and are protective against all subtypes. We have recently generated a murine anti-HBs monoclonal antibody (4G4), which can neutralize HBV infection in HepaRG cells and recognize most of the escape mutant forms of HBsAg. Here, we describe the production and characterization of the chimeric human-murine antibody 4G4 (c-4G4). Variable region genes of heavy and light chains of the m-4G4 were cloned and fused to constant regions of human kappa and IgG1 by splice overlap extension (SOE) PCR. The chimeric antibody was expressed in Chinese Hamster Ovary (CHO)-K1 cells and purified from culture supernatant. Competition ELISA proved that both antibodies bind the same epitope within HBsAg. Antigen-binding studies using ELISA and Western blot showed that c-4G4 has retained the affinity and specificity of the parental murine antibody, and displayed a similar pattern of reactivity to 13 escape mutant forms of HBsAg. Both, the parental and c-4G4 showed a comparably high HBV neutralization capacity in cell culture even at the lowest concentration (0.6μg/ml). Due to the ability of c-4G4 to recognize most of the sub-genotypes and escape mutants of HBsAg, this antibody either alone or in combination with other anti-HBs antibodies could be considered as a potent alternative for Hepatitis B immune globulin (HBIG) as an HBV infection prophylactic or for passive immunotherapy against HBV infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Detection of S-gene 'a' determinant variants in hepatitis B patients with both positive HBsAg and HBsAb markers

    International Nuclear Information System (INIS)

    Wu Yueping; Ling Yongwu; Huang Songping; Wang Shipeng; Chen Yufeng; Mao Liping; Lu Jianrong

    2005-01-01

    Objective: To explore the S-gene 'a' determinant variants in hepatitis B patients with both positive HBsAg and HBsAb markers and the effect on the antigenicity of HBsAg. Methods: Quantitative determination of HBV - DNA with competent PCR microfluidic chit method was performed in eight sera specimens from seven hepatitis B patients with both positive HBsAg and HBsAb markers. HBV S-gene was amplified with nested PCR, the PCR product was directly examined for any sequence variant of the amino acids. HBV markers were tested with the very sensitive ELISA/MEIA method in these seven patients. The above rests were also performed in 15 children after failed immunization with hepatitis B vaccine and 9 recipients of liver transplantation for terminal hepatitis B treated with HBIG and lamivudine, serving as controls. Results: The HBsAb contents in the seven patients were all below 80 mIu/ml. Two of the patients with positive HBV-DNA showed no 'a' determinant variant. Two of the four HBV-DNA negative patients demonstrated amino-acid variants (126, 131). One patients who was originally HBV-DNA positive but later turned negative after treatment with interferon and lamivudine demonstrated variant (126). In the 9 patients after successful liver transplantation, the HBsAb contents were all about 150mIu/ml with negative HBV-DNA and no variant. In the 15 immunization failures, HBV-DNA was positive in 14 of them, with 2 cases of variant at 145, 1 case at 126 and 1 case at 134. Conclusion: In some patients with chronic B hepatitis with both positive HBsAg and HBsAb markers, as well as in some vaccine immunization failures, there were 'a' determinant variants, which might alter the antigenicity of HBsAg with escape from the neutralization of low HBsAb. The 'a' determinant variant might also affect the replication of the virus. In this study, no variant was shown in patients after successful liver transplantation. However, the number of patients was too small and the result was of no

  4. Clinical evaluation of the Abbott RealTime MTB Assay for direct detection of Mycobacterium tuberculosis-complex from respiratory and non-respiratory samples.

    Science.gov (United States)

    Hinić, Vladimira; Feuz, Kinga; Turan, Selda; Berini, Andrea; Frei, Reno; Pfeifer, Karin; Goldenberger, Daniel

    2017-05-01

    Rapid and reliable diagnosis is crucial for correct management of tuberculosis. The Abbott RealTime MTB Assay represents a novel qualitative real-time PCR assay for direct detection of M. tuberculosis-complex (MTB) DNA from respiratory samples. The test targets two highly conserved sequences, the multi-copy insertion element IS6110 and the protein antigen B (PAB) gene of MTB, allowing even the detection of IS6610-deficient strains. We evaluated this commercial diagnostic test by analyzing 200 respiratory and, for the first time, 87 non-respiratory clinical specimens from our tertiary care institution and compared its results to our IS6110-based in-house real-time PCR for MTB as well as MTB culture. Overall sensitivity for Abbott RealTime MTB was 100% (19/19) in smear positive and 87.5% (7/8) in smear negative specimens, while the specificity of the assay was 100% (260/260). For both non-respiratory smear positive and smear negative specimens Abbott RealTime MTB tests showed 100% (8/8) sensitivity and 100% (8/8) specificity. Cycle threshold (Ct) value analysis of 16 MTB positive samples showed a slightly higher Ct value of the Abbott RealTime MTB test compared to our in-house MTB assay (mean delta Ct = 2.55). In conclusion, the performance of the new Abbott RealTime MTB Assay was highly similar to culture and in-house MTB PCR. We document successful analysis of 87 non-respiratory samples with the highly automated Abbott RealTime MTB test with no inhibition observed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Multicenter evaluation of the new Abbott Realtime assays for quantitative detection of human immunodeficiency virus type 1 and hepatitis C virus RNA

    NARCIS (Netherlands)

    M. Schutten (Martin); D. Peters (D.); N. Back (Nicole); A.W. van den Beld (Annewieke); B. Beuselinck (B.); V. Foulongne (V.); A.M. Geretti (Anna Maria); L. Pandiani (L.); M. Tiemann; H.G.M. Niesters (Bert)

    2007-01-01

    textabstractThe analytical performances of the new Abbott RealTime hepatitis C virus (HCV) and human immunodeficiency virus type 1 viral load assays were compared at nine laboratories with different competitor assays. These included the Abbott LcX, Bayer Versant bDNA, Roche COBAS Amplicor, and Roche

  6. PRISM -- A tool for modelling proton energy deposition in semiconductor materials

    International Nuclear Information System (INIS)

    Oldfield, M.K.; Underwood, C.I.

    1996-01-01

    This paper presents a description of, and test results from, a new PC based software simulation tool PRISM (Protons in Semiconductor Materials). The model describes proton energy deposition in complex 3D sensitive volumes of semiconductor materials. PRISM is suitable for simulating energy deposition in surface-barrier detectors and semiconductor memory devices, the latter being susceptible to Single-Event Upset (SEU) and Multiple-Bit Upset (MBU). The design methodology on which PRISM is based, together with the techniques used to simulate ion transport and energy deposition, are described. Preliminary test results used to analyze the PRISM model are presented

  7. Historic and current hepatitis B viral DNA and quantitative HBsAg level are not associated with cirrhosis in non-Asian women with chronic hepatitis B.

    Science.gov (United States)

    Harkisoen, S; Arends, J E; van den Hoek, J A R; Whelan, J; van Erpecum, K J; Boland, G J; Hoepelman, A I M

    2014-12-01

    Some studies done in Asian patients have shown that serum levels of hepatitis B virus (HBV) DNA predict the development of cirrhosis. However, it is unclear whether this also applies for non-Asian patients. This study investigated historic and current HBV DNA and quantitative hepatitis B surface antigen (HBsAg) levels as predictors of cirrhosis in non-Asian women with chronic HBV. A retrospective cohort study of non-Asian women with chronic HBV was performed. Among other variables, HBV DNA and quantitative HBsAg levels were measured in stored historic serum samples obtained during pregnancy (period 1990-2004) and current serum samples (period 2011-2012) to determine any association with liver cirrhosis by liver stiffness measurement (LSM). One hundred and nineteen asymptomatic, treatment-naïve non-Asian women were included; the median number of years between the historic sample and the current sample was 17 (interquartile range (IQR) 13-20). The median historic log HBV DNA and quantitative log HBsAg levels were 2.5 (IQR 1.9-3.4) IU/ml and 4.2 (IQR 3.6-4.5) IU/ml, respectively. LSM diagnosed 14 patients (12%) with F3-F4 fibrosis, i.e. stiffness >8.1kPa. No association of cirrhosis was found with historic HBV DNA (relative risk (RR) 0.34, 95% confidence interval (CI) 0.05-2.44) or with the quantitative HBsAg level (HBsAg level >1000 IU/ml, RR 0.35, 95% CI 0.11-1.11). Multivariable analysis identified alcohol consumption (odds ratio (OR) 6.4, 95% CI 1.3-30.1), aspartate aminotransferase >0.5 times the upper limit of normal (OR 15.4, 95% CI 1.9-122.6), and prothrombin time (OR 12.0, 95% CI 1.2-120.4), but not HBV DNA or quantitative HBsAg level, to be independent predictors of the presence of cirrhosis. Neither historic nor current HBV DNA or the quantitative HBsAg level is associated with the development of HBV-related cirrhosis in non-Asian women. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. Effects of Accretionary Prisms on 3-D Long-Period Ground Motion Simulations

    Science.gov (United States)

    Guo, Y.; Koketsu, K.; Miyake, H.

    2014-12-01

    The accretionary prism along the subduction zones such as the Middle America trench or the Nankai trough is considered as an important factor affecting the generation and propagation of long-period ground motions. In Japan, the great earthquake along the Nankai subduction zone which is expected to occur in the near future can generate large long-period ground motions in the metropolitan areas such as Osaka, Nagoya and Tokyo. To investigate the effect of accretionary prism on long-period ground motions, we performed simulations of long-period ground motions for the event (Mw 7.1) that occurred off the Kii peninsula, Japan, at 10:07 on 5 September 2004 (UTC). Our simulation model ranged from the Kinki region to the Kanto region, and included the Osaka, Nobi and Kanto basin. We calculated long-period ground motions for four types of 3-D velocity structure models: (a) model with the accretionary prism (reference model), (b) model where accretionary prism has different 3-D geometry from the reference model, (c) model with the accretionary prism whose velocity, density and Q-value are shifted, (d) model without the accretionary prism. We compared the waveforms calculated for these models and concluded that the accretionary prism along the Nankai subduction zone plays roles in reducing the amplitude of direct waves and extending the duration of coda waves. This is attributed to the trap effect of accretionary prism. Our simulation also suggested that, the edge geometry along the landward side of accretionary prism has major effects on the processes of generation and propagation of long-period ground motions.

  9. Posintro™-HBsAg, a modified ISCOM including HBsAg, induces strong cellular and humoral responses

    DEFF Research Database (Denmark)

    Schiött, Asa; Larsson, Kristina; Manniche, Søren

    2011-01-01

    HBsAg vaccine formulation, Posintro™-HBsAg, was compared to two commercial hepatitis B vaccines including aluminium or monophosphoryl lipid A (MPL) and the two adjuvant systems MF59 and QS21 in their efficiency to prime both cellular and humoral immune responses. The Posintro™-HBsAg induced...

  10. Reverse time migration of prism waves for salt flank delineation

    KAUST Repository

    Dai, Wei; Schuster, Gerard T.

    2013-01-01

    In this paper, we present a new reverse time migration method for imaging salt flanks with prism wave reflections. It consists of four steps: (1) migrating the seismic data with conventional RTM to give the RTM image; (2) using the RTM image as a reflectivity model to simulate source-side reflections with the Born approximation; (3) zero-lag correlation of the source-side reflection wavefields and receiver-side wavefields to produce the prism wave migration image; and (4) repeating steps 2 and 3 for the receiver-side reflections. An advantage of this method is that there is no need to pick the horizontal reflectors prior to migration of the prism waves. It also separately images the vertical structures at a different step to reduce crosstalk interference. The disadvantage of prism wave migration algorithm is that its computational cost is twice that of conventional RTM. The empirical results with a salt model suggest that prism wave migration can be an effective method for salt flank delineation in the absence of diving waves.

  11. Reverse time migration of prism waves for salt flank delineation

    KAUST Repository

    Dai, Wei

    2013-09-22

    In this paper, we present a new reverse time migration method for imaging salt flanks with prism wave reflections. It consists of four steps: (1) migrating the seismic data with conventional RTM to give the RTM image; (2) using the RTM image as a reflectivity model to simulate source-side reflections with the Born approximation; (3) zero-lag correlation of the source-side reflection wavefields and receiver-side wavefields to produce the prism wave migration image; and (4) repeating steps 2 and 3 for the receiver-side reflections. An advantage of this method is that there is no need to pick the horizontal reflectors prior to migration of the prism waves. It also separately images the vertical structures at a different step to reduce crosstalk interference. The disadvantage of prism wave migration algorithm is that its computational cost is twice that of conventional RTM. The empirical results with a salt model suggest that prism wave migration can be an effective method for salt flank delineation in the absence of diving waves.

  12. PRISM: An innovative liquid metal fast breeder reactor

    International Nuclear Information System (INIS)

    Kruger, G.B.; Boardman, C.E.; Olich, E.E.; Switick, D.M.

    1986-01-01

    This paper describes an innovative sodium-cooled reactor concept employing small certified reactor modules coupled with a standardized steam generator system. The total plant employs nine PRISM reactors (power reactor inherently safe module) in three 415 MWe power blocks. The PRISM design concept utilizes inherent safety characteristics and modularity to improve licensability, reduce owner's risk, and reduce costs. The relatively small size of each reactor module facilitates the use of passive, inherent self-shutdown and shutdown heat removal features, which permit design simplification and reduction of safety-related systems. It is proposed that a single PRISM module be used in a full-scale integrated reactor safety test. Results from the test would be used to obtain NRC certification of the standard design

  13. An OPTIMIZE study retrospective analysis for management of telaprevir-treated hepatitis C virus (HCV)-infected patients by use of the Abbott RealTime HCV RNA assay.

    Science.gov (United States)

    Sarrazin, Christoph; Dierynck, Inge; Cloherty, Gavin; Ghys, Anne; Janssen, Katrien; Luo, Donghan; Witek, James; Buti, Maria; Picchio, Gaston; De Meyer, Sandra

    2015-04-01

    Protease inhibitor (PI)-based response-guided triple therapies for hepatitis C virus (HCV) infection are still widely used. Noncirrhotic treatment-naive and prior relapser patients receiving telaprevir-based treatment are eligible for shorter, 24-week total therapy if HCV RNA is undetectable at both weeks 4 and 12. In this study, the concordance in HCV RNA assessments between the Roche High Pure System/Cobas TaqMan and Abbott RealTime HCV RNA assays and the impacts of different HCV RNA cutoffs on treatment outcome were evaluated. A total of 2,629 samples from 663 HCV genotype 1 patients receiving telaprevir/pegylated interferon/ribavirin in OPTIMIZE were analyzed using the High Pure System and reanalyzed using Abbott RealTime (limits of detection, 15.1 IU/ml versus 8.3 IU/ml; limits of quantification, 25 IU/ml versus 12 IU/ml, respectively). Overall, good concordance was observed between the assays. Using undetectable HCV RNA at week 4, 34% of the patients would be eligible for shorter treatment duration with Abbott RealTime versus 72% with the High Pure System. However, using Abbott RealTime, a similar proportion (74%) would be eligible. Of the patients receiving 24-week total therapy, 87% achieved a sustained virologic response with undetectable HCV RNA by the High Pure System or Abbott RealTime; however, 92% of the patients with undetectable HCV RNA by Abbott RealTime achieved a sustained virologic response. Using undetectable HCV RNA as the cutoff, the more sensitive Abbott RealTime assay would identify fewer patients eligible for shorter treatment than the High Pure System. Our data confirm the Abbott RealTime assay, to determine eligibility for shortened PI-based HCV treatment. (The study was registered with ClinicalTrials.gov under registration no. NCT01241760.). Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  14. PRISM Software: Processing and Review Interface for Strong‐Motion Data

    Science.gov (United States)

    Jones, Jeanne M.; Kalkan, Erol; Stephens, Christopher D.; Ng, Peter

    2017-01-01

    A continually increasing number of high‐quality digital strong‐motion records from stations of the National Strong Motion Project (NSMP) of the U.S. Geological Survey, as well as data from regional seismic networks within the United States, calls for automated processing of strong‐motion records with human review limited to selected significant or flagged records. The NSMP has developed the Processing and Review Interface for Strong Motion data (PRISM) software to meet this need. In combination with the Advanced National Seismic System Quake Monitoring System (AQMS), PRISM automates the processing of strong‐motion records. When used without AQMS, PRISM provides batch‐processing capabilities. The PRISM software is platform independent (coded in Java), open source, and does not depend on any closed‐source or proprietary software. The software consists of two major components: a record processing engine composed of modules for each processing step, and a review tool, which is a graphical user interface for manual review, edit, and processing. To facilitate use by non‐NSMP earthquake engineers and scientists, PRISM (both its processing engine and review tool) is easy to install and run as a stand‐alone system on common operating systems such as Linux, OS X, and Windows. PRISM was designed to be flexible and extensible to accommodate implementation of new processing techniques. All the computing features have been thoroughly tested.

  15. MEGARA Optics: stain removal in PBM2Y prisms

    International Nuclear Information System (INIS)

    Aguirre-Aguirre, D; Izazaga-Pérez, R; Carrasco, E; Villalobos-Mendoza, B; De Paz, A Gil; Gallego, J; Iglesias, J

    2017-01-01

    MEGARA is the new integral-field and multi-object optical spectrograph for the GTC. For medium and high resolution, the dispersive elements are volume phase holographic gratings, sandwiched between two flat windows and two prisms of high optical precision. The prisms are made of Ohara PBM2Y optical glass. After the prisms polishing process, some stains appeared on the surfaces. For this, in this work is shown the comparative study of five different products (muriatic acid, paint remover, sodium hydroxide, aqua regia and rare earth liquid polish) used for trying to eliminate the stains of the HR MEGARA prisms. It was found that by polishing with the hands the affected area, and using a towel like a kind of pad, and polish during five minutes using rare earth, the stains disappear completely affecting only a 5% the rms of the surface quality. Not so the use of the other products that did not show any apparent result. (paper)

  16. Impact of inter-genotypic recombination and probe cross-reactivity on the performance of the Abbott RealTime HCV Genotype II assay for hepatitis C genotyping.

    Science.gov (United States)

    Sridhar, Siddharth; Yip, Cyril C Y; Chan, Jasper F W; To, Kelvin K W; Cheng, Vincent C C; Yuen, Kwok-Yung

    2018-05-01

    The Abbott RealTime HCV Genotype II assay (Abbott-RT-HCV assay) is a real-time PCR based genotyping method for hepatitis C virus (HCV). This study measured the impact of inter-genotypic recombination and probe cross-reactivity on the performance of the Abbott-RT-HCV assay. 517 samples were genotyped using the Abbott-RT-HCV assay over a one-year period, 34 (6.6%) were identified as HCV genotype 1 without further subtype designation raising the possibility of inaccurate genotyping. These samples were subjected to confirmatory sequencing. 27 of these 34 (79%) samples were genotype 1b while five (15%) were genotype 6. One HCV isolate was an inter-genotypic 1a/4o recombinant. This is a novel natural HCV recombinant that has never been reported. Inter-genotypic recombination and probe cross-reactivity can affect the accuracy of the Abbott-RT-HCV assay, both of which have significant implications on antiviral regimen choice. Confirmatory sequencing of ambiguous results is crucial for accurate genotyping. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Immune-escape mutations and stop-codons in HBsAg develop in a large proportion of patients with chronic HBV infection exposed to anti-HBV drugs in Europe

    DEFF Research Database (Denmark)

    Colagrossi, Luna; Hermans, Lucas E; Salpini, Romina

    2018-01-01

    structure of HBV genome, some immune-escape mutations or stop-codons in HBsAg can derive from drug-resistance mutations in RT. This study is aimed at gaining insight in prevalence and characteristics of immune-associated escape mutations, and stop-codons in HBsAg in chronically HBV-infected patients...

  18. PRISM reactor. An option for plutonium disposition?

    Energy Technology Data Exchange (ETDEWEB)

    Fehlinger, Sebastian; Friess, Friederike; Kuett, Moritz [IANUS, Technische Universitaet Darmstadt (Germany)

    2015-07-01

    The Power Reactor Innovative Small Module (PRISM) is sodium cooled fast reactor model. The energy output depends on the core configuration, however with an energy output of approximately 300 MWe, the PRISM reactor belongs to the class of small modular reactors. Beside using the reactor as a breeder reactor or for the transmutation of nuclear waste, it might also be used as a burner reactor for separated plutonium. This includes for example U.S.-American excess weapon-grade plutonium as well as separated reactor-grade plutonium. Recently, there has been an ongoing discussion in GB to use the PRISM reactor to dispose their excess civilian plutonium. Depending on the task, the core configuration varies slightly. We will present different layouts and the matching MCNP models, these models can then be used to conduct depletion calculations. From these results, analysis of the change in the plutonium isotopics in the spent fuel, the amount of fissioned plutonium, and the possible annual plutonium throughputs is possible.

  19. Quantitative HBsAg and HBeAg predict hepatitis B seroconversion after initiation of HAART in HIV-HBV coinfected individuals.

    Directory of Open Access Journals (Sweden)

    Gail V Matthews

    Full Text Available OBJECTIVE: Anti-HBe seroconversion and HBsAg loss are important therapeutic endpoints in patients with hepatitis B virus (HBV infection. Quantitative measures of hepatitis B surface antigen (qHBsAg and e antigen (qHBeAg have been identified as potentially useful indicators of therapeutic response in HBV monoinfection. The aim of this study was to examine serological change including quantitative biomarkers in HIV-HBV coinfected patients initiating HBV active antiretroviral therapy (ART. METHODS: HIV-HBV coinfected individuals from Thailand were followed for up to 168 weeks post ART. Rates and associations of qualitative serological change were determined. Longitudinal changes in qHBsAg and qHBeAg were measured and their utility as predictors of response examined. RESULTS: Forty seven patients were included of whom 27 (57% were HBeAg positive at baseline. Median CD4 count was 48 cells/mm(3. Over a median follow-up of 108 weeks 48% (13/27 lost HBeAg, 12/27 (44% achieved anti-HBe seroconversion and 13% (6/47 HBsAg loss. Anti-HBe seroconversion was associated with higher baseline ALT (p = 0.034, lower qHBsAg (p = 0.015, lower qHBeAg (p = 0.031 and greater HBV DNA decline to week 24 (p = 0.045. Sensitivity and specificity for qHBsAg and qHBeAg decline of >0.5 log at week 12 and >1.0 log at week 24 were high for both anti-HBe seroconversion and HBsAg loss. CONCLUSIONS: Rates of serological change in these HIV-HBV coinfected individuals with advanced immunodeficiency initiating HBV-active ART were high. Baseline and on treatment factors were identified that were associated with a greater likelihood of subsequent anti-HBe seroconversion, including both quantitative HBsAg and HBeAg, suggesting these biomarkers may have utility in this clinical setting.

  20. Isolated HBsAg positivity in a Mexican patient with newly diagnosed lupus nephritis

    Directory of Open Access Journals (Sweden)

    Guillermo Delgado-García

    2017-01-01

    Conclusions: Isolated HBsAg positivity may result from multiple causes, one of which is cross-reactivity. To the best of our knowledge, this is the first report of a false-positive reading using CMIA technique in an active lupus patient. It is reasonable to stress that lupus patients with a positive screening for HBV should undergo a confirmatory assay (such as genomic detection, since this diagnosis may have important therapeutic implications.

  1. Evaluations of 1990 PRISM design revisions

    International Nuclear Information System (INIS)

    Van Tuyle, G.J.; Slovik, G.C.; Chan, B.C.; Aronson, A.L.; Kennett, R.J.

    1992-03-01

    Analyses of the 1990 version of the PRISM Advanced Liquid Metal Reactor (ALMR) design are presented and discussed. Most of the calculations were performed using BNL computer codes, particularly SSC and MINET. In many cases, independent BNL calculations were compared against analyses presented by General Electric when they submitted the PRISM design revisions for evaluation by the Nuclear Regulatory Commission (NRC). The current PRISM design utilizes the metallic fuel developed by Argonne National Laboratory (ANL) which facilitates the passive/''inherent'' shutdown mechanism that acts to shut down reactor power production whenever the system overheats. There are a few vulnerabilities in the passive shutdown, with the most worrisome being the positive feedback from sodium density decreases or sodium voiding. Various postulated unscrammed events were examined by GE and/or BNL, and much of the analysis discussed in this report is focused on this category of events. For the most part, the BNL evaluations confirm the information submitted by General Electric. The principal areas of concern are related to the performance of the ternary metal fuel, and may be resolved as ANL continues with its fuel development and testing program

  2. Multicenter evaluation of the new Abbott RealTime assays for quantitative detection of human immunodeficiency virus type 1 and hepatitis C virus RNA

    NARCIS (Netherlands)

    Schutten, Martin; Peters, D; Back, N K T; Beld, M; Beuselinck, K; Foulongne, V; Geretti, A-M; Pandiani, L; Tiemann, C; Niesters, H G M

    The analytical performances of the new Abbott RealTime hepatitis C virus (HCV) and human immunodeficiency virus type 1 viral load assays were compared at nine laboratories with different competitor assays. These included the Abbott LcX, Bayer Versant bDNA, Roche COBAS Amplicor, and Roche COBAS

  3. Multicenter evaluation of the new Abbott RealTime assays for quantitative detection of human immunodeficiency virus type 1 and hepatitis C virus RNA

    NARCIS (Netherlands)

    Schutten, M.; Peters, D.; Back, N. K. T.; Beld, M.; Beuselinck, K.; Foulongne, V.; Geretti, A.-M.; Pandiani, L.; Tiemann, C.; Niesters, H. G. M.

    2007-01-01

    The analytical performances of the new Abbott RealTime hepatitis C virus (HCV) and human immunodeficiency virus type 1 viral load assays were compared at nine laboratories with different competitor assays. These included the Abbott LcX, Bayer Versant bDNA, Roche COBAS Amplicor, and Roche COBAS

  4. Petal–like modes in Porro prism resonators

    CSIR Research Space (South Africa)

    Litvin, IA

    2007-10-01

    Full Text Available , and then proposed in 1962 by Gould et al [1] as a means to overcome misalignment problems in optical resonators employing Fabry–Perot cavities by replacing the end face mirrors with crossed roof prisms. Lasers based on this principle have been developed over... of America OCIS codes: (140.4780) Optical resonators; (260.0260) Physical optics; (140.3410) Laser resonators; (230.5480) Prisms; (140.0140) Lasers and laser optics References and links 1. G. Gould, S. Jacobs, P. Rabinowitz and T. Shultz, “Crossed Roof...

  5. Clinical utility of Abbott Precision Xceed Pro® ketone meter in diabetic patients.

    Science.gov (United States)

    Yu, Hoi-Ying Elsie; Agus, Michael; Kellogg, Mark D

    2011-11-01

    Diagnosis and management of diabetic ketoacidosis (DKA) often rely on the measurement of urine ketones along with blood glucose, anion gap, and pH. These values, however, do not reliably reflect the severity of ketoacidosis. The Abbott Precision Xceed Pro® meter is an FDA-approved device that quantitatively measures β-hydroxybutyrate (BOH) in whole blood. This study was undertaken to determine whether the ketone meter meets the analytical criteria to aid DKA diagnosis and management in the hospital. 54 heparinized venous whole blood BOH concentrations from 27 diabetic patients were measured by the Abbott meter, and compared with the plasma BOH concentrations measured with Stanbio reagent (reference method). Measurements were done in the hospital central laboratory. Of the 54 pairs of specimens analyzed, 17 pairs displayed a difference of >15% between the two methods. Nearly all discrepant points occurred when BOH >5 mmol/L (reference method). Linearity evaluation revealed that the meter is not linear from 0.0 to 8.0 mmol/L, contrary to the claim by the manufacturer. Further, we identified acetoacetate, a metabolite commonly present in DKA patients, as a potential interfering substance for the meter BOH measurement. BOH measurements by the Abbott meter up to 3 mmol/L correlate well with the reference method, but become discrepant above that point. While this characteristic may be useful in the diagnosis of DKA, it may not allow clinicians to serially follow the response to therapy in hospitalized DKA patients with BOH values greater than 5 mmol/L (reference method). © 2011 John Wiley & Sons A/S.

  6. [Dental enamel prisms of Mesopithecus pentelicus Wagner, 1839, compared with recent cercopithecids (Primates: Cercopithecidae)].

    Science.gov (United States)

    Dostal, A; Zapfe, H

    1986-01-01

    The dental enamel prisms of Cercopithecidae were examined by scanning electron microscopy. The main task of this study was to show the prism morphology representatives of different genera as well as their comparison with the fossil Mesopithecus pentelicus Wagner, 1839. The method used to show the enamel prisms was to etch the tooth surface with hydrochloric acid. In this way the outlines of the prisms were better contrasted for the descriptive morphology of the prisms than in etching with phosphoric acid. Two types were determined, in accord with the systematic division into subfamilies. In the subfamily Cercopithecinae elongated slender prisms were dominating, some with pointed, others with truncated tops. Most characteristic of this type were Macaca and Cercopithecus. An exception was Papio hamadryas which had broader, rounded prisms. In this way it differed largely from P. anubis whose prisms were short and mostly triangular. A very interesting fact was that very different patterns were found in P. anubis and P. hamadryas, although these two species are regarded as only one species by many authors. The second subfamily, the Colobinae, was characterized by broader prisms with a rounded shape, nearly as long as wide. Exceptions of the 'Colobine type' were at first Colobus with prisms little longer than wide and secondly Nasalis, with mostly parallel sides and truncated tops of the prisms. The prism outlines of Mesopithecus showed the greatest similarity to those of Presbytis which represents the characteristic 'Colobine type'. This fact confirmed the actual systematic position of the fossil Mesopithecus within the subfamily Colobinae. In addition to previously known primitive features of Mesopithecus within the subfamily of Colobinae, we present here a further concrete, common feature with asiatic Colobines.

  7. Performance of the Abbott RealTime CT/NG for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae▿

    Science.gov (United States)

    Gaydos, C. A.; Cartwright, C. P.; Colaninno, P.; Welsch, J.; Holden, J.; Ho, S. Y.; Webb, E. M.; Anderson, C.; Bertuzis, R.; Zhang, L.; Miller, T.; Leckie, G.; Abravaya, K.; Robinson, J.

    2010-01-01

    A multicenter clinical study was conducted to evaluate the performance characteristics of the Abbott RealTime CT/NG assay, a multiplex real-time PCR assay, for simultaneous detection of Chlamydia trachomatis and Neisseria gonorrhoeae. The specimens were collected from a total of 3,832 male and female subjects at 16 geographically diverse sites. Specimens included male and female urine samples, male urethral swabs, female endocervical swabs, and self-collected and clinician-collected vaginal swabs. Specimens were tested with the automated Abbott RealTime CT/NG assay, Aptima Combo 2 assay (Gen-Probe), ProbeTec ET CT/GC assay (Becton Dickinson), and culture for N. gonorrhoeae. The Aptima Combo 2 assay, the ProbeTec assay, and the N. gonorrhoeae culture were used as the reference assays. For each subject, a patient infected status (PIS) was determined based on the combined results from the reference assays. The overall prevalence in female subjects was 8.9% for C. trachomatis and 3.8% for N. gonorrhoeae. The overall male prevalence was 18.2% for C. trachomatis and 16.7% for N. gonorrhoeae. The overall sensitivity and specificity of the Abbott RealTime CT/NG assay were 92.4% and 99.2% for C. trachomatis and 96.9% and 99.7% for N. gonorrhoeae, respectively. In comparison, the sensitivity and specificity, respectively, for the Aptima Combo 2 assay were 94.5% and 99.0% for C. trachomatis and 96.1% and 99.5% for N. gonorrhoeae, and those for the ProbeTec ET assay were 90.3% and 99.5% for C. trachomatis and 92.0% and 97.3% for N. gonorrhoeae in this study. The Abbott RealTime CT/NG assay offers C. trachomatis and N. gonorrhoeae dual detection with high sensitivity and specificity. The automated assay provides a useful alternative nucleic acid amplification assay for clinical laboratories and clinicians. PMID:20668135

  8. Performance of the Abbott RealTime CT/NG for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

    Science.gov (United States)

    Gaydos, C A; Cartwright, C P; Colaninno, P; Welsch, J; Holden, J; Ho, S Y; Webb, E M; Anderson, C; Bertuzis, R; Zhang, L; Miller, T; Leckie, G; Abravaya, K; Robinson, J

    2010-09-01

    A multicenter clinical study was conducted to evaluate the performance characteristics of the Abbott RealTime CT/NG assay, a multiplex real-time PCR assay, for simultaneous detection of Chlamydia trachomatis and Neisseria gonorrhoeae. The specimens were collected from a total of 3,832 male and female subjects at 16 geographically diverse sites. Specimens included male and female urine samples, male urethral swabs, female endocervical swabs, and self-collected and clinician-collected vaginal swabs. Specimens were tested with the automated Abbott RealTime CT/NG assay, Aptima Combo 2 assay (Gen-Probe), ProbeTec ET CT/GC assay (Becton Dickinson), and culture for N. gonorrhoeae. The Aptima Combo 2 assay, the ProbeTec assay, and the N. gonorrhoeae culture were used as the reference assays. For each subject, a patient infected status (PIS) was determined based on the combined results from the reference assays. The overall prevalence in female subjects was 8.9% for C. trachomatis and 3.8% for N. gonorrhoeae. The overall male prevalence was 18.2% for C. trachomatis and 16.7% for N. gonorrhoeae. The overall sensitivity and specificity of the Abbott RealTime CT/NG assay were 92.4% and 99.2% for C. trachomatis and 96.9% and 99.7% for N. gonorrhoeae, respectively. In comparison, the sensitivity and specificity, respectively, for the Aptima Combo 2 assay were 94.5% and 99.0% for C. trachomatis and 96.1% and 99.5% for N. gonorrhoeae, and those for the ProbeTec ET assay were 90.3% and 99.5% for C. trachomatis and 92.0% and 97.3% for N. gonorrhoeae in this study. The Abbott RealTime CT/NG assay offers C. trachomatis and N. gonorrhoeae dual detection with high sensitivity and specificity. The automated assay provides a useful alternative nucleic acid amplification assay for clinical laboratories and clinicians.

  9. Reflection by Porro Prisms

    Science.gov (United States)

    Greenslade, Thomas B.

    2010-04-01

    Students all know that reflection from a plane mirror produces an image that is reversed right to left and so cannot be read by anyone but Leonardo da Vinci, who kept his notes in mirror writing. A useful counter-example is the Porro prism, which produces an image that is not reversed.

  10. Multivariable control for the PRISM ALMR

    International Nuclear Information System (INIS)

    Wilson, T.L.; Wagner, W.K.

    1989-01-01

    This paper describes the application of state variable control design methods in the conceptual design of two key system level controllers in the PRISM ALMR. The PRISM plant concept consists of three power blocks, each made up of three identical reactors and steam generator modules connected to one turbine. Operation of these physically distributed systems is directed by a hierarchy of controllers at the system, power block, and plant levels. The system level controllers in this paper are the reactivity controllers for movement of the six control rods in each of the nine reactor modules, and the feedwater control of the three parallel steam generators in each of the three power blocks. 4 refs., 6 figs., 1 tab

  11. HBsAg d and y subtypes determined by inhibition radio-immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Wilkinson, R [Border Blood Transfusion Service, East London (South Africa)

    1981-12-01

    An inhibition radioimmunoassay for the detection of HBsAg/d and HBsAg/y antigens is described. A survey of 211 asymptomatic HBsAg positive blood donors showed 190 to be of type HBsAg/d and 3 to be of type HBsAg/y, while the remaining 18 could not be typed. Of 43 patients with acute hepatitis 39 were type HBsAg/d and 4 were type HBsAg/y. The statistically significant (p smaller than 0,01) increase in type HBsAg/y may reflect a changing pattern in offending viral strain with the passage of time.

  12. Left-Deviating Prism Adaptation in Left Neglect Patient: Reflexions on a Negative Result

    Directory of Open Access Journals (Sweden)

    Jacques Luauté

    2012-01-01

    Full Text Available Adaptation to right-deviating prisms is a promising intervention for the rehabilitation of patients with left spatial neglect. In order to test the lateral specificity of prism adaptation on left neglect, the present study evaluated the effect of left-deviating prism on straight-ahead pointing movements and on several classical neuropsychological tests in a group of five right brain-damaged patients with left spatial neglect. A group of healthy subjects was also included for comparison purposes. After a single session of exposing simple manual pointing to left-deviating prisms, contrary to healthy controls, none of the patients showed a reliable change of the straight-ahead pointing movement in the dark. No significant modification of attentional paper-and-pencil tasks was either observed immediately or 2 hours after prism adaptation. These results suggest that the therapeutic effect of prism adaptation on left spatial neglect relies on a specific lateralized mechanism. Evidence for a directional effect for prism adaptation both in terms of the side of the visuomanual adaptation and therefore possibly in terms of the side of brain affected by the stimulation is discussed.

  13. Local Seismicity Recorded by ChilePEPPER: Implications for Dynamic Accretionary Prism Response and Long-term Prism Evolution

    Science.gov (United States)

    de Moor, A.; Trehu, A. M.; Tryon, M. D.

    2015-12-01

    To investigate the dynamic response of the outer accretionary wedge updip from the patch of greatest slip during the Mw8.8 2010 Maule earthquake, 10 Ocean Bottom Seismometers (OBS) were deployed from May 2012 to March 2013 in a small array with an inter-instrument spacing of ~12 km . Nine instruments were recovered, with 4 recording data on 3 intermediate-band 3-component seismometers and a differential pressure gauge and 5 recording data from absolute pressure gauges. [note: All instruments were also equipped with a fluid flow meter sensitive to flow rates as low as 0.0001 cm/yr in or out of the sediments. However, no flow signal was detected.] Here we present hypocenters for 569 local events that have S-P times less than 17 seconds (i.e. within ~125 km of the array) using hand-picked arrival times and a 1D velocity model derived from a 2D seismic refraction profile through the region (Moscoso et al 2011, EPSL). We analyze the distribution of seismicity in the context of published slip models, ChilePEPPER high-resolution seismic reflection data, critical taper analysis done by Cubas et al 2013 (EPSL), and offshore gravity data. The data show distinct segmentation within the outer prism. The northern section of the study area is characterized by a lack of seismicity, accretion of nearly all incoming sediment and a prism at critical taper. In contrast, abundant seismicity, significant sediment underthrusting at the deformation front and a prism below critical taper angle characterize the southern part of the study area. Both coseismic slip and post-rupture local seismicity can be related to density anomalies within the upper plate as revealed by free air gravity data corrected for the effects of bathymetry and the subducting plate. [ChilePEPPER - Project Evaluating Prism Post-Earthquake Response

  14. Superconducting magnetic Wollaston prism for neutron spin encoding

    Energy Technology Data Exchange (ETDEWEB)

    Li, F., E-mail: fankli@indiana.edu; Parnell, S. R.; Wang, T.; Baxter, D. V. [Center for Exploration of Energy and Matter, Indiana University, Bloomington, Indiana 47408 (United States); Hamilton, W. A. [Neutron Sciences Directorate, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37830 (United States); Maranville, B. B. [National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); Semerad, R. [Ceraco Ceramic Coating GmbH, Ismaning 85737 (Germany); Cremer, J. T. [Adelphi Technology Inc., Redwood City, California 94063 (United States); Pynn, R. [Center for Exploration of Energy and Matter, Indiana University, Bloomington, Indiana 47408 (United States); Neutron Sciences Directorate, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37830 (United States)

    2014-05-15

    A magnetic Wollaston prism can spatially split a polarized neutron beam into two beams with different neutron spin states, in a manner analogous to an optical Wollaston prism. Such a Wollaston prism can be used to encode the trajectory of neutrons into the Larmor phase associated with their spin degree of freedom. This encoding can be used for neutron phase-contrast radiography and in spin echo scattering angle measurement (SESAME). In this paper, we show that magnetic Wollaston prisms with highly uniform magnetic fields and low Larmor phase aberration can be constructed to preserve neutron polarization using high temperature superconducting (HTS) materials. The Meissner effect of HTS films is used to confine magnetic fields produced electromagnetically by current-carrying HTS tape wound on suitably shaped soft iron pole pieces. The device is cooled to ∼30 K by a closed cycle refrigerator, eliminating the need to replenish liquid cryogens and greatly simplifying operation and maintenance. A HTS film ensures that the magnetic field transition within the prism is sharp, well-defined, and planar due to the Meissner effect. The spin transport efficiency across the device was measured to be ∼98.5% independent of neutron wavelength and energizing current. The position-dependent Larmor phase of neutron spins was measured at the NIST Center for Neutron Research facility and found to agree well with detailed simulations. The phase varies linearly with horizontal position, as required, and the neutron beam shows little depolarization. Consequently, the device has advantages over existing devices with similar functionality and provides the capability for a large neutron beam (20 mm × 30 mm) and an increase in length scales accessible to SESAME to beyond 10 μm. With further improvements of the external coupling guide field in the prototype device, a larger neutron beam could be employed.

  15. Superconducting magnetic Wollaston prism for neutron spin encoding

    Science.gov (United States)

    Li, F.; Parnell, S. R.; Hamilton, W. A.; Maranville, B. B.; Wang, T.; Semerad, R.; Baxter, D. V.; Cremer, J. T.; Pynn, R.

    2014-05-01

    A magnetic Wollaston prism can spatially split a polarized neutron beam into two beams with different neutron spin states, in a manner analogous to an optical Wollaston prism. Such a Wollaston prism can be used to encode the trajectory of neutrons into the Larmor phase associated with their spin degree of freedom. This encoding can be used for neutron phase-contrast radiography and in spin echo scattering angle measurement (SESAME). In this paper, we show that magnetic Wollaston prisms with highly uniform magnetic fields and low Larmor phase aberration can be constructed to preserve neutron polarization using high temperature superconducting (HTS) materials. The Meissner effect of HTS films is used to confine magnetic fields produced electromagnetically by current-carrying HTS tape wound on suitably shaped soft iron pole pieces. The device is cooled to ˜30 K by a closed cycle refrigerator, eliminating the need to replenish liquid cryogens and greatly simplifying operation and maintenance. A HTS film ensures that the magnetic field transition within the prism is sharp, well-defined, and planar due to the Meissner effect. The spin transport efficiency across the device was measured to be ˜98.5% independent of neutron wavelength and energizing current. The position-dependent Larmor phase of neutron spins was measured at the NIST Center for Neutron Research facility and found to agree well with detailed simulations. The phase varies linearly with horizontal position, as required, and the neutron beam shows little depolarization. Consequently, the device has advantages over existing devices with similar functionality and provides the capability for a large neutron beam (20 mm × 30 mm) and an increase in length scales accessible to SESAME to beyond 10 μm. With further improvements of the external coupling guide field in the prototype device, a larger neutron beam could be employed.

  16. Optimization of SPR signals: Monitoring the physical structures and refractive indices of prisms

    Science.gov (United States)

    Maisarah Mukhtar, Wan; Halim, Razman Mohd; Hassan, Hazirah

    2017-11-01

    Surface plasmon resonance (SPR) can only be achieved if sufficient energy is provided at the boundary between metal and dielectric. An employment of prism as a light coupler by using Kretschmann configuration is one of the alternative for the production of adequate energy to be generated as surface plasmon polaritons (SPP). This work is carried out to investigate the effect of physical structure of the prism and its refractive index to the excitation of SPPs. A 50nm gold thin metal film with dielectric constant of ɛ=-12.45i+1.3 was deposited on the hypotenuse surface of the prisms. The physical structures of the prisms were varied such as triangular, conical, hemispherical and half cylindrical. These prisms were classified into two types of refractive indices (RI), namely n=1.51(type BK7) and n=1.77(type SF11). Based on SPR curve analyses, we discovered that strong SPR signals which consist of 82.98% photons were excited as SPPs can be obtained by using type-BK7 prism with physical structures of hemispherical or half cylindrical. From the view of selectivity ability as sensors, the usage of type-SF11 prisms (half cylindrical and hemispherical) able to enhance this impressive feature in which sharp SPR curves with small FWHM values were obtained. In conclusion, apart from properties of thin film materials, the physical structure of prisms and their RI values play crucial roles to obtain optimum SPR signal. High sensitivity SPR sensor can be established with the appointment of type-BK7 prisms (hemispherical or half cylindrical shape) as light couplers.

  17. Optimization of SPR signals: Monitoring the physical structures and refractive indices of prisms

    Directory of Open Access Journals (Sweden)

    Mukhtar Wan Maisarah

    2017-01-01

    Full Text Available Surface plasmon resonance (SPR can only be achieved if sufficient energy is provided at the boundary between metal and dielectric. An employment of prism as a light coupler by using Kretschmann configuration is one of the alternative for the production of adequate energy to be generated as surface plasmon polaritons (SPP. This work is carried out to investigate the effect of physical structure of the prism and its refractive index to the excitation of SPPs. A 50nm gold thin metal film with dielectric constant of ɛ=-12.45i+1.3 was deposited on the hypotenuse surface of the prisms. The physical structures of the prisms were varied such as triangular, conical, hemispherical and half cylindrical. These prisms were classified into two types of refractive indices (RI, namely n=1.51(type BK7 and n=1.77(type SF11. Based on SPR curve analyses, we discovered that strong SPR signals which consist of 82.98% photons were excited as SPPs can be obtained by using type-BK7 prism with physical structures of hemispherical or half cylindrical. From the view of selectivity ability as sensors, the usage of type-SF11 prisms (half cylindrical and hemispherical able to enhance this impressive feature in which sharp SPR curves with small FWHM values were obtained. In conclusion, apart from properties of thin film materials, the physical structure of prisms and their RI values play crucial roles to obtain optimum SPR signal. High sensitivity SPR sensor can be established with the appointment of type-BK7 prisms (hemispherical or half cylindrical shape as light couplers.

  18. PRISM, Processing and Review Interface for Strong Motion Data Software

    Science.gov (United States)

    Kalkan, E.; Jones, J. M.; Stephens, C. D.; Ng, P.

    2016-12-01

    A continually increasing number of high-quality digital strong-motion records from stations of the National Strong Motion Project (NSMP) of the U.S. Geological Survey (USGS), as well as data from regional seismic networks within the U.S., calls for automated processing of strong-motion records with human review limited to selected significant or flagged records. The NSMP has developed the Processing and Review Interface for Strong Motion data (PRISM) software to meet this need. PRISM automates the processing of strong-motion records by providing batch-processing capabilities. The PRISM software is platform-independent (coded in Java), open-source, and does not depend on any closed-source or proprietary software. The software consists of two major components: a record processing engine composed of modules for each processing step, and a graphical user interface (GUI) for manual review and processing. To facilitate the use by non-NSMP earthquake engineers and scientists, PRISM (both its processing engine and GUI components) is easy to install and run as a stand-alone system on common operating systems such as Linux, OS X and Windows. PRISM was designed to be flexible and extensible in order to accommodate implementation of new processing techniques. Input to PRISM currently is limited to data files in the Consortium of Organizations for Strong-Motion Observation Systems (COSMOS) V0 format, so that all retrieved acceleration time series need to be converted to this format. Output products include COSMOS V1, V2 and V3 files as: (i) raw acceleration time series in physical units with mean removed (V1), (ii) baseline-corrected and filtered acceleration, velocity, and displacement time series (V2), and (iii) response spectra, Fourier amplitude spectra and common earthquake-engineering intensity measures (V3). A thorough description of the record processing features supported by PRISM is presented with examples and validation results. All computing features have been

  19. A meta-analysis of the antiviral activity of the HBV-specific immunotherapeutic TG1050 confirms its value over a wide range of HBsAg levels in a persistent HBV pre-clinical model.

    Science.gov (United States)

    Kratzer, Roland; Sansas, Benoît; Lélu, Karine; Evlachev, Alexei; Schmitt, Doris; Silvestre, Nathalie; Inchauspé, Geneviève; Martin, Perrine

    2018-02-01

    Pre-clinical models mimicking persistent hepatitis B virus (HBV) expression are seldom, do not capture all features of a human chronic infection and due to their complexity, are subject to variability. We report a meta-analysis of seven experiments performed with TG1050, an HBV-targeted immunotherapeutic, 1 in an HBV-persistent mouse model based on the transduction of mice by an adeno-associated virus coding for an infectious HBV genome (AAV-HBV). To mimic the clinical diversity seen in HBV chronically infected patients, AAV-HBV transduced mice displaying variable HBsAg levels were treated with TG1050. Overall mean percentages of responder mice, displaying decrease in important clinical parameters i.e. HBV-DNA (viremia) and HBsAg levels, were 52% and 51% in TG1050 treated mice, compared with 8% and 22%, respectively, in untreated mice. No significant impact of HBsAg level at baseline on response to TG1050 treatment was found. TG1050-treated mice displayed a significant shorter Time to Response (decline in viral parameters) with an Hazard Ratio (HR) of 8.3 for viremia and 2.6 for serum HBsAg. The mean predicted decrease for TG1050-treated mice was 0.5 log for viremia and 0.8 log for HBsAg, at the end of mice follow-up, compared to no decrease for viremia and 0.3 log HBsAg decrease for untreated mice. For mice receiving TG1050, a higher decline of circulating viremia and serum HBsAg level over time was detected by interaction term meta-analysis with a significant treatment effect (p = 0.002 and pHBV-persistent model mimicking clinical situations.

  20. Reactivation of viral replication in anti-HBe positive chronic HBsAg carriers

    DEFF Research Database (Denmark)

    Krogsgaard, K; Aldershvile, J; Kryger, Peter

    1990-01-01

    Reactivation of hepatitis B virus replication was investigated in an unselected group of 44 HBV DNA negative, anti-HBe positive chronic HBsAg carriers. Twenty-five patients (54%) were intravenous drug addicts and 7 (16%) were male homosexuals. Sixteen patients had evidence of delta infection...... to an annual reactivation rate of 5%. Reactivation in four patients was detected by reversion to HBV DNA positivity only, whereas HBeAg/anti-HBe status remained unchanged. Two patients became both HBV DNA and HBeAg positive. None of the patients developed hepatitis-like symptoms and transaminase elevation...

  1. Automated analysis of objective-prism spectra

    International Nuclear Information System (INIS)

    Hewett, P.C.; Irwin, M.J.; Bunclark, P.; Bridgeland, M.T.; Kibblewhite, E.J.; Smith, M.G.

    1985-01-01

    A fully automated system for the location, measurement and analysis of large numbers of low-resolution objective-prism spectra is described. The system is based on the APM facility at the University of Cambridge, and allows processing of objective-prism, grens or grism data. Particular emphasis is placed on techniques to obtain the maximum signal-to-noise ratio from the data, both in the initial spectral estimation procedure and for subsequent feature identification. Comparison of a high-quality visual catalogue of faint quasar candidates with an equivalent automated sample demonstrates the ability of the APM system to identify all the visually selected quasar candidates. In addition, a large population of new, faint (msub(J)approx. 20) candidates is identified. (author)

  2. PRISM software—Processing and review interface for strong-motion data

    Science.gov (United States)

    Jones, Jeanne M.; Kalkan, Erol; Stephens, Christopher D.; Ng, Peter

    2017-11-28

    Rapidly available and accurate ground-motion acceleration time series (seismic recordings) and derived data products are essential to quickly providing scientific and engineering analysis and advice after an earthquake. To meet this need, the U.S. Geological Survey National Strong Motion Project has developed a software package called PRISM (Processing and Review Interface for Strong-Motion data). PRISM automatically processes strong-motion acceleration records, producing compatible acceleration, velocity, and displacement time series; acceleration, velocity, and displacement response spectra; Fourier amplitude spectra; and standard earthquake-intensity measures. PRISM is intended to be used by strong-motion seismic networks, as well as by earthquake engineers and seismologists.

  3. Single-Frequency Nd:YAG Ring Lasers with Corner Cube Prism

    Science.gov (United States)

    Wu, Ke-Ying; Yang, Su-Hui; Zhao, Chang-Ming; Wei, Guang-Hui

    2000-10-01

    We put forward another form of the non-planar ring lasers, in which the corner cube prism is the key element and the Nd:YAG crystal is used as a Porro prism to enclose the ring resonator. The phase shift due to the total internal reflections of the three differently orientated reflection planes of the corner cube prism, Faraday rotation in the Nd:YAG crystal placed in a magnetic field and the different output coupling in S and P polarization form an optical diode and enforce the single-frequency generating power. A round trip analysis of the polarization properties of the resonator is made by the evaluation of Jones matrix.

  4. Rational design and evaluation of HBsAg polymeric nanoparticles as antigen delivery carriers.

    Science.gov (United States)

    Dewangan, Hitesh Kumar; Pandey, Tarun; Maurya, Lakshmi; Singh, Sanjay

    2018-05-01

    The present work is focused on the development and evaluation of single dose sustained-release Hepatitis B surface antigen (HBsAg) loaded nanovaccine for Hepatitis B. The conventional treatment suffers from repeated administration and hence requires a booster dose. Therefore, polymeric nanovaccine of HBsAg was developed by double emulsion solvent evaporation technique, utilizing central composite design for formulation optimization. The effects of independent variables (like polymer amount, stabilizer concentration, aqueous/organic phase ratio and homogenizer speed) were also studied on critical quality attributes like particle size and entrapment efficiency. Nanovaccine was characterized in terms of physicochemical parameters, release, internalization and in vivo immunological evaluation in BALB/c mice after administration by different routes such as oral, sub-cutaneous, nasal and intramuscular. The designed nanovaccine demonstrated nanometric size with smooth surface, negative zeta potential, maximum entrapment, sustained release and better internalization in macrophage and MRC-5 cell line. The immune-stimulating activity of nanovaccine administered by different routes was evaluated by measuring anti-HBsAg titre like specific immunoglobulin IgG and IgA response and cytokine level (interleukin-2, interferon-Y) measurement. The results indicated that the nanovaccine administered by intramuscular route produced better humoral as well as cellular responses and potential carriers for antigen delivery at single dose administration via intramuscular route. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Prism adaptation does not alter object-based attention in healthy participants

    Science.gov (United States)

    Bultitude, Janet H.

    2013-01-01

    Hemispatial neglect (‘neglect’) is a disabling condition that can follow damage to the right side of the brain, in which patients show difficulty in responding to or orienting towards objects and events that occur on the left side of space. Symptoms of neglect can manifest in both space- and object-based frames of reference. Although patients can show a combination of these two forms of neglect, they are considered separable and have distinct neurological bases. In recent years considerable evidence has emerged to demonstrate that spatial symptoms of neglect can be reduced by an intervention called prism adaptation. Patients point towards objects viewed through prismatic lenses that shift the visual image to the right. Approximately five minutes of repeated pointing results in a leftward recalibration of pointing and improved performance on standard clinical tests for neglect. The understanding of prism adaptation has also been advanced through studies of healthy participants, in whom adaptation to leftward prismatic shifts results in temporary neglect-like performance. Here we examined the effect of prism adaptation on the performance of healthy participants who completed a computerised test of space- and object-based attention. Participants underwent adaptation to leftward- or rightward-shifting prisms, or performed neutral pointing according to a between-groups design. Significant pointing after-effects were found for both prism groups, indicating successful adaptation. In addition, the results of the computerised test revealed larger reaction-time costs associated with shifts of attention between two objects compared to shifts of attention within the same object, replicating previous work. However there were no differences in the performance of the three groups, indicating that prism adaptation did not influence space- or object-based attention for this task. When combined with existing literature, the results are consistent with the proposal that prism

  6. Accurate geometrical optics model for single-lens stereovision system using a prism.

    Science.gov (United States)

    Cui, Xiaoyu; Lim, Kah Bin; Guo, Qiyong; Wang, DaoLei

    2012-09-01

    In this paper, we proposed a new method for analyzing the image formation of a prism. The prism was considered as a single optical system composed of some planes. By analyzing each plane individually and then combining them together, we derived a transformation matrix which can express the relationship between an object point and its image by the refraction of a prism. We also explained how to use this matrix for epipolar geometry and three-dimensional point reconstruction. Our method is based on optical geometry and could be used in a multiocular prism. Experimentation results are presented to prove the accuracy of our method is better than former researchers' and is comparable with that of the multicamera stereovision system.

  7. Quartz-Enhanced Photoacoustic Spectroscopy with Right-Angle Prism

    Directory of Open Access Journals (Sweden)

    Yongning Liu

    2016-02-01

    Full Text Available A right-angle prism was used to enhance the acoustic signal of a quartz-enhanced photoacoustic spectroscopy (QEPAS system. The incident laser beam was parallelly inverted by the right-angle prism and passed through the gap between two tuning fork prongs again to produce another acoustic excitation. Correspondingly, two pairs of rigid metal tubes were used as acoustic resonators with resonance enhancement factors of 16 and 12, respectively. The QEPAS signal was enhanced by a factor of 22.4 compared with the original signal, which was acquired without resonators or a prism. In addition, the system noise was reduced a little with double resonators due to the Q factor decrease. The signal-to-noise ratio (SNR was greatly improved. Additionally, a normalized noise equivalent absorption coefficient (NNEA of 5.8 × 10−8 W·cm−1·Hz−1/2 was achieved for water vapor detection in the atmosphere.

  8. A study on suppressing transmittance fluctuations for air-gapped Glan-type polarizing prisms

    Science.gov (United States)

    Zhang, Chuanfa; Li, Dailin; Zhu, Huafeng; Li, Chuanzhi; Jiao, Zhiyong; Wang, Ning; Xu, Zhaopeng; Wang, Xiumin; Song, Lianke

    2018-05-01

    Light intensity transmittance is a key parameter for the design of polarizing prisms, while sometimes its experimental curves based on spatial incident angle presents periodical fluctuations. Here, we propose a novel method for completely suppressing these fluctuations via setting a glued error angle in the air gap of Glan-Taylor prisms. The proposal consists of: an accurate formula of the intensity transmittance for Glan-Taylor prisms, a numerical simulation and a contrast experiment of Glan-Taylor prisms for analyzing the causes of the fluctuations, and a simple method for accurately measuring the glued error angle. The result indicates that when the setting glued error angle is larger than the critical angle for a certain polarizing prism, the fluctuations can be completely suppressed, and a smooth intensity transmittance curve can be obtained. Besides, the critical angle in the air gap for suppressing the fluctuations is decreased with the increase of beam spot size. This method has the advantage of having less demand for the prism position in optical systems.

  9. Glucose meters: evaluation of the new formulation measuring strips from Roche (Accu-Chek) and Abbott (MediSense).

    Science.gov (United States)

    Dimeski, G; Jones, B W; Tilley, V; Greenslade, M N; Russell, A W

    2010-07-01

    Both Roche and Abbott have released new glucose meter strips. They supply the entire Australian hospital market. The present study compared the performance of the new strips utilizing various specimen types (capillary, venous lithium heparin whole blood, venous lithium heparin plasma and serum) and evaluated how well they comply with the International Standards Organization (ISO) 15197 criteria. The study included imprecision, patient comparison and interference studies. Participants with and without diabetes were recruited to evaluate the performance of various specimen types against the Beckman DxC800 glucose method. The strips were tested for different interferences: galactose, maltose, lactose, Icodextrin, Intragam, paracetamol, sodium, ascorbic acid, variable strip storage temperature, haematocrit, haemolysis and lipaemia. The imprecision of the two strips was approximately 5% or less, except for the Abbott strip at very low values (1.4 mmol/L), approximately 7%. In total, 78% and 84%, respectively, of the results from the finger prick capillary specimens with the Roche (Accu-Chek Performa meter) and Abbott (Optium Xceed meter) strips, not 95% or greater as recommended by the ISO guideline, were within the recommended limits compared with reference plasma estimation on laboratory analysers. Galactose, ascorbic acid, haematocrit and sodium on the Roche and ascorbic acid and haematocrit on the Abbott strip continue to interfere to a variable degree with the glucose measurement. Analytically small differences exist between the glucose meter strips. The most significant analytical difference with the strips was at low glucose levels when compared with laboratory analyses and this may be of clinical importance. The impact of some of the interferences is variable between the two strips. Individuals, health-care professionals and health-care institutions should consider these data when selecting glucose meters for the management of people with diabetes mellitus.

  10. Decentralization and Participatory Decision-Making: Implementing School-Based Management in the Abbott Districts.

    Science.gov (United States)

    Walker, Elaine M.

    2000-01-01

    This study examined issues faced during implementation of school-based management (SBM) in New Jersey's special needs or Abbott districts, using a literature review, surveys of K-12 schools, and focus groups with central office administrators. The study examined forms of SBM, team operations, local autonomy versus state power, skills required to…

  11. Asymmetrical effects of adaptation to left- and right-shifting prisms depends on pre-existing attentional biases.

    Science.gov (United States)

    Goedert, Kelly M; Leblanc, Andrew; Tsai, Sen-Wei; Barrett, Anna M

    2010-09-01

    Proposals that adaptation with left-shifting prisms induces neglect-like symptoms in normal individuals rely on a dissociation between the postadaptation performance of individuals trained with left- versus right-shifting prisms (e.g., Colent, Pisella, & Rossetti, 2000). A potential problem with this evidence is that normal young adults have an a priori leftward bias (e.g., Jewell & McCourt, 2000). In Experiment 1, we compared the line bisection performance of young adults to that of aged adults, who as a group may lack a leftward bias in line bisection. Participants trained with both left- and right-shifting prisms. Consistent with our hypothesis, while young adults demonstrated aftereffects for left, but not right prisms, aged adults demonstrated reliable aftereffects for both prisms. In Experiment 2, we recruited a larger sample of young adults, some of whom were right-biased at baseline. We observed an interaction between baseline bias and prism-shift, consistent with the results of Experiment 1: Left-biased individuals showed a reduced aftereffect when training with right-shifting prisms and right-biased individuals showed a reduced aftereffect when training with left-shifting prisms. These results suggest that previous failures to find generalizable aftereffects with right-shifting prisms may be driven by participants' baseline biases rather than specific effects of the prism itself.

  12. Micropropagation of transgenic lettuce containing HBsAg as a method of mass-scale production of standardised plant material for biofarming purposes.

    Science.gov (United States)

    Pniewski, Tomasz; Czyż, Marcin; Wyrwa, Katarzyna; Bociąg, Piotr; Krajewski, Paweł; Kapusta, Józef

    2017-01-01

    Micropropagation protocol of transgenic lettuce bearing S-, M- and L-HBsAg was developed for increased production of uniformised material for oral vaccine preparation. Effective manufacturing of plant-based biopharmaceuticals, including oral vaccines, depends on sufficient content of a protein of interest in the initial material and its efficient conversion into an administrable formulation. However, stable production of plants with a uniformised antigen content is equally important for reproducible processing. This can be provided by micropropagation techniques. Here, we present a protocol for micropropagation of transgenic lettuce lines bearing HBV surface antigens: S-, M- and L-HBsAg. These were multiplied through axillary buds to avoid the risk of somaclonal variation. Micropropagation effectiveness reached 3.5-5.7 per passage, which implies potential production of up to 6600 plant clones within a maximum 5 months. Multiplication and rooting rates were statistically homogenous for most transgenic and control plants. For most lines, more than 90 % of clones obtained via in vitro micropropagation had HBsAg content as high as reference plants directly developed from seeds. Clones were also several times more uniform in HBsAg expression. Variation coefficients of HBsAg content did not exceed 10 % for approximately 40-85 % of clones, or reached a maximum 20 % for 90 % of all clones. Tissue culture did not affect total and leaf biomass yields. Seed production for clones was decreased insignificantly and did not impact progeny condition. Micropropagation facilitates a substantial increase in the production of lettuce plants with high and considerably equalised HBsAg contents. This, together with the previously reported optimisation of plant tissue processing and its long-term stability, constitutes a successive step in manufacturing of a standardised anti-HBV oral vaccine of reliable efficacy.

  13. Prism adaptation for spatial neglect after stroke: translational practice gaps.

    Science.gov (United States)

    Barrett, A M; Goedert, Kelly M; Basso, Julia C

    2012-10-01

    Spatial neglect increases hospital morbidity and costs in around 50% of the 795,000 people per year in the USA who survive stroke, and an urgent need exists to reduce the care burden of this condition. However, effective acute treatment for neglect has been elusive. In this article, we review 48 studies of a treatment of intense neuroscience interest: prism adaptation training. Due to its effects on spatial motor 'aiming', prism adaptation training may act to reduce neglect-related disability. However, research failed, first, to suggest methods to identify the 50-75% of patients who respond to treatment; second, to measure short-term and long-term outcomes in both mechanism-specific and functionally valid ways; third, to confirm treatment utility during the critical first 8 weeks poststroke; and last, to base treatment protocols on systematic dose-response data. Thus, considerable investment in prism adaptation research has not yet touched the fundamentals needed for clinical implementation. We suggest improved standards and better spatial motor models for further research, so as to clarify when, how and for whom prism adaptation should be applied.

  14. Utility of the Abbott RealTime HCV Genotype Plus RUO assay used in combination with the Abbott RealTime HCV Genotype II assay.

    Science.gov (United States)

    He, Chao; Germer, Jeffrey J; Ptacek, Elizabeth R; Bommersbach, Carl E; Mitchell, P Shawn; Yao, Joseph D C

    Hepatitis virus C (HCV) genotype (GT) determination and subtype (ST) differentiation (1a versus 1b) remain important for the selection of appropriate direct-acting antiviral (DAA) therapy. This study is a retrospective comparison of HCV GT and ST result distribution when using the Abbott RealTime HCV Genotype II assay (HCVGT II) alone and in combination with the Abbott RealTime HCV Genotype Plus RUO assay (HCVGT Plus) for routine testing of clinical serum specimens at a reference laboratory. HCVGT II results of specimens tested from June 2014 through January 2016 (period 1) were compared with combined results from HCVGT II and HCVGT Plus (HCVGT II/Plus) performed from January 2016 through January 2017 (period 2). A total of 44,127 and 25,361 specimens were tested during periods 1 and 2, respectively. Use of HCVGT II/Plus significantly reduced the frequency of GT 1 results without ST (0.4%) when compared to preliminary HCVGT II results during period 2 (5.3%; p < 0.01) and final HCVGT II results in period 1 (5.5%; p < 0.01). HCVGT II/Plus also resulted in GT 6 reactivity in 38 specimens with results of "HCV detected" (n = 17) or GT 1 (n = 21) following initial HCVGT II testing during period 2. When compared to the use of HCVGT II alone, HCVGT II/Plus significantly reduced the frequency of GT 1 without ST results observed in a large reference laboratory, while also enabling the identification of HCV GT 6. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Design of airborne imaging spectrometer based on curved prism

    Science.gov (United States)

    Nie, Yunfeng; Xiangli, Bin; Zhou, Jinsong; Wei, Xiaoxiao

    2011-11-01

    A novel moderate-resolution imaging spectrometer spreading from visible wavelength to near infrared wavelength range with a spectral resolution of 10 nm, which combines curved prisms with the Offner configuration, is introduced. Compared to conventional imaging spectrometers based on dispersive prism or diffractive grating, this design possesses characteristics of small size, compact structure, low mass as well as little spectral line curve (smile) and spectral band curve (keystone or frown). Besides, the usage of compound curved prisms with two or more different materials can greatly reduce the nonlinearity inevitably brought by prismatic dispersion. The utilization ratio of light radiation is much higher than imaging spectrometer of the same type based on combination of diffractive grating and concentric optics. In this paper, the Seidel aberration theory of curved prism and the optical principles of Offner configuration are illuminated firstly. Then the optical design layout of the spectrometer is presented, and the performance evaluation of this design, including spot diagram and MTF, is analyzed. To step further, several types of telescope matching this system are provided. This work provides an innovational perspective upon optical system design of airborne spectral imagers; therefore, it can offer theoretic guide for imaging spectrometer of the same kind.

  16. Porous Ni-Co-Mn oxides prisms for high performance electrochemical energy storage

    Science.gov (United States)

    Zhao, Jianbo; Li, Man; Li, Junru; Wei, Chengzhen; He, Yuyue; Huang, Yixuan; Li, Qiaoling

    2017-12-01

    Porous Ni-Co-Mn oxides prisms have been successfully synthesized via a facile route. The process involves the preparation of nickel-cobalt-manganese acetate hydroxide by a simple co-precipitation method and subsequently the thermal treatment. The as-synthesized Ni-Co-Mn oxides prisms had a large surface area (96.53 m2 g-1) and porous structure. As electrode materials for supercapacitors, porous Ni-Co-Mn oxides prisms showed a high specific capacitance of 1623.5 F g-1 at 1.0 A g-1. Moreover, the porous Ni-Co-Mn oxides prisms were also employed as positive electrode materials to assemble flexible solid-state asymmetric supercapacitors. The resulting flexible device had a maximum volumetric energy density (0.885 mW h cm-3) and power density (48.9 mW cm-3). Encouragingly, the flexible device exhibited good cycling stability with only about 2.2% loss after 5000 charge-discharge cycles and excellent mechanical stability. These results indicate that porous Ni-Co-Mn oxides prisms have the promising application in high performance electrochemical energy storage.

  17. Modeling laser brightness from cross porro prism resonators

    CSIR Research Space (South Africa)

    Forbes, A

    2006-07-01

    Full Text Available , independent of the angle of incidence. Thus an initial planar wavefront remains planar after reflection. This property was initially exploited in Michelson interferometers to relax the tolerances on mis-alignment, and then proposed in 1962 by Gould et al1... 20 25 30 35 0 20 40 60 80 100 Prism Angle (Degrees) Nu mb er o f P et als divisions. These relationships lead to the following equation for the allowed angles of rotation of the prism edges relative to one another for repeatability...

  18. Heterophilic interference in specimens yielding false-reactive results on the Abbott 4th generation ARCHITECT HIV Ag/Ab Combo assay.

    Science.gov (United States)

    Lavoie, S; Caswell, D; Gill, M J; Kadkhoda, K; Charlton, C L; Levett, P N; Hatchette, T; Garceau, R; Maregmen, J; Mazzulli, T; Needle, R; Kadivar, K; Kim, J

    2018-04-12

    False-reactivity in HIV-negative specimens has been detected in HIV fourth-generation antigen/antibody or 'combo' assays which are able to detect both anti-HIV-1/HIV-2 antibodies and HIV-1 antigen. We sought to characterize these specimens and determine the effect of heterophilic interference. Specimens previously testing as false-reactive on the Abbott ARCHITECT HIV Ag/Ab combo assay and re-tested on a different (Siemens ADVIA Centaur HIV Ag/Ab) assay. A subset of these specimens were also pre-treated with heterophilic blocking agents and re-tested on the Abbott assay. Here we report that 95% (252/264) of clinical specimens that were repeatedly reactive on the Abbott ARCHITECT HIV Ag/Ab combo assay (S/Co range, 0.94-678) were negative when re-tested on a different fourth generation HIV combo assay (Siemens ADVIA Centaur HIV Ag/Ab). All 264 samples were subsequently confirmed to be HIV negative. On a small subset (57) of specimens with available volume, pre-treatment with two different reagents (HBT; Heterophilic Blocking Tube, NABT; Non-Specific Blocking Tube) designed to block heterophilic antibody interference either eliminated (HBT) or reduced (NABT) the false reactivity when re-tested on the ARCHITECT HIV Ag/Ab combo assay. Our results suggest that the Abbott ARCHITECT HIV Ag/Ab combo assay can be prone to heterophilic antibody interference. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  19. Performance of the Abbott RealTime MTB RIF/INH resistance assay when used to test Mycobacterium tuberculosis specimens from Bangladesh

    Directory of Open Access Journals (Sweden)

    Kostera J

    2018-05-01

    Full Text Available Joshua Kostera, Gregor Leckie, Klara Abravaya, Hong Wang Abbott Molecular, Abbott Laboratories, Des Plaines, IL, USA Introduction: The Abbott RealTime MTB RIF/INH Resistance Assay (RT MTB RIF/INH is an assay for the detection of rifampicin (RIF- and/or isoniazid (INH-resistant Mycobacterium tuberculosis (MTB. The assay can be used to test sputum, bronchial alveolar lavage, and N-Acetyl-L-Cysteine (NALC/NaOH pellets prepared from these samples. The assay can be used in direct testing mode, or in reflex mode following a MTB positive result produced by its companion assay, Abbott RT MTB. Methods: In this study, the direct testing mode was used to test paired sputum and NALC/NaOH pellets prepared from sputum collected from Bangladesh TB patients. One hundred and thirty two paired samples were tested. Results: The RT MTB RIF/INH inhibition rate was 0%. One hundred and twenty-two paired samples had results above the assay limit of detection and were analyzed by comparing with results from phenotypic drug sensitivity testing, GeneXpert MTB/RIF (Xpert, and MTBDR plus (Hain. RT MTB RIF/INH results were in good agreement with those of GeneXpert and Hain. Conclusion: The ability of this assay to detect RIF and INH resistance may contribute to the global control of multidrug resistant tuberculosis. Keywords: tuberculosis, rifampicin, isoniazid, resistance

  20. Analysis of transverse field distributions in Porro prism resonators

    Science.gov (United States)

    Litvin, Igor A.; Burger, Liesl; Forbes, Andrew

    2007-05-01

    A model to describe the transverse field distribution of the output beam from porro prism resonators is proposed. The model allows the prediction of the output transverse field distribution by assuming that the main areas of loss are located at the apexes of the porro prisms. Experimental work on a particular system showed some interested correlations between the time domain behavior of the resonator and the transverse field output. These findings are presented and discussed.

  1. 3D Printed Prisms with Tunable Dispersion for the THz Frequency Range

    Science.gov (United States)

    Busch, Stefan F.; Castro-Camus, Enrique; Beltran-Mejia, Felipe; Balzer, Jan C.; Koch, Martin

    2018-06-01

    Here, we present a 3D printed prism for THz waves made out of an artificial dielectric material in which the dispersion can be tuned by external compression. The artificial material consists of thin dielectric layers with variable air spacings which has been produced using a fused deposition molding process. The material properties are carefully characterized and the functionality of the prisms is in a good agreement with the underlying theory. These prisms are durable, lightweight, inexpensive, and easy to produce.

  2. 3D Printed Prisms with Tunable Dispersion for the THz Frequency Range

    Science.gov (United States)

    Busch, Stefan F.; Castro-Camus, Enrique; Beltran-Mejia, Felipe; Balzer, Jan C.; Koch, Martin

    2018-04-01

    Here, we present a 3D printed prism for THz waves made out of an artificial dielectric material in which the dispersion can be tuned by external compression. The artificial material consists of thin dielectric layers with variable air spacings which has been produced using a fused deposition molding process. The material properties are carefully characterized and the functionality of the prisms is in a good agreement with the underlying theory. These prisms are durable, lightweight, inexpensive, and easy to produce.

  3. Multi-energy CT based on a prior rank, intensity and sparsity model (PRISM)

    International Nuclear Information System (INIS)

    Gao, Hao; Osher, Stanley; Yu, Hengyong; Wang, Ge

    2011-01-01

    We propose a compressive sensing approach for multi-energy computed tomography (CT), namely the prior rank, intensity and sparsity model (PRISM). To further compress the multi-energy image for allowing the reconstruction with fewer CT data and less radiation dose, the PRISM models a multi-energy image as the superposition of a low-rank matrix and a sparse matrix (with row dimension in space and column dimension in energy), where the low-rank matrix corresponds to the stationary background over energy that has a low matrix rank, and the sparse matrix represents the rest of distinct spectral features that are often sparse. Distinct from previous methods, the PRISM utilizes the generalized rank, e.g., the matrix rank of tight-frame transform of a multi-energy image, which offers a way to characterize the multi-level and multi-filtered image coherence across the energy spectrum. Besides, the energy-dependent intensity information can be incorporated into the PRISM in terms of the spectral curves for base materials, with which the restoration of the multi-energy image becomes the reconstruction of the energy-independent material composition matrix. In other words, the PRISM utilizes prior knowledge on the generalized rank and sparsity of a multi-energy image, and intensity/spectral characteristics of base materials. Furthermore, we develop an accurate and fast split Bregman method for the PRISM and demonstrate the superior performance of the PRISM relative to several competing methods in simulations. (papers)

  4. 76 FR 4283 - Foreign-Trade Zone 153-San Diego, CA; Application for Manufacturing Authority; Abbott...

    Science.gov (United States)

    2011-01-25

    ... finished product) include: resins, plastic tubing, stent components, plastic packaging, plastic clips... noted above. FTZ designation would further allow Abbott to realize logistical benefits through the use of weekly customs entry procedures. Customs duties also could possibly be deferred or reduced on...

  5. ePRISM: A case study in multiple proxy and mixed temporal resolution integration

    Science.gov (United States)

    Robinson, Marci M.; Dowsett, Harry J.

    2010-01-01

    As part of the Pliocene Research, Interpretation and Synoptic Mapping (PRISM) Project, we present the ePRISM experiment designed I) to provide climate modelers with a reconstruction of an early Pliocene warm period that was warmer than the PRISM interval (similar to 3.3 to 3.0 Ma), yet still similar in many ways to modern conditions and 2) to provide an example of how best to integrate multiple-proxy sea surface temperature (SST) data from time series with varying degrees of temporal resolution and age control as we begin to build the next generation of PRISM, the PRISM4 reconstruction, spanning a constricted time interval. While it is possible to tie individual SST estimates to a single light (warm) oxygen isotope event, we find that the warm peak average of SST estimates over a narrowed time interval is preferential for paleoclimate reconstruction as it allows for the inclusion of more records of multiple paleotemperature proxies.

  6. Intricacies of Feedback in Computer-based Prism Adaptation Therapy

    DEFF Research Database (Denmark)

    Wilms, Inge Linda; Rytter, Hana Malá

    Prism Adaptation Therapy (PAT) is an intervention method for treatment of attentional disorders, such as neglect e.g. 1,2. The method involves repeated pointing at specified targets with or without prism glasses using a specifically designed wooden box. The aim of this study was to ascertain...... whether the PAT method can be executed with similar effect using a computer with a touch screen.   62 healthy subjects were subjected to two experimental conditions: 1) pointing out at targets using the original box, 2) pointing out at targets on a computer attached touch screen. In both conditions......, the subjects performed a pre-test consisting of 30 targets without feedback, then an exposure-test of 90 targets with prism glasses and feedback, and finally a post-test of 60 targets, with no glasses and no feedback. Two experiments were carried out, 1) the feedback was provided by showing a cross...

  7. Comparison of the Abbott m2000 HIV-1 Real-Time and Roche AMPLICOR Monitor v1.5 HIV-1 assays on plasma specimens from Rakai, Uganda.

    Science.gov (United States)

    Ssebugenyi, I; Kizza, A; Mpoza, B; Aluma, G; Boaz, I; Newell, K; Laeyendecker, O; Shott, J P; Serwadda, D; Reynolds, S J

    2011-07-01

    The need for viral load (VL) monitoring of HIV patients receiving antiretroviral therapy (ART) in resource-limited settings (RLS) has become apparent with studies showing the limitations of immunological monitoring. We compared the Abbott m2000 Real-Time (Abbott) HIV-1 assay with the Roche AMPLICOR Monitor v1.5 (Roche) HIV-1 assay over a range of VL concentrations. Three hundred and eleven plasma samples were tested, including 164 samples from patients on ART ≥ six months and 147 from ART-naïve patients. The Roche assay detected ≥400 copies/mL in 158 (50.8%) samples. Of these, Abbott produced 145 (91.8%) detectable results ≥400 copies/mL; 13 (8.2%) samples produced discrepant results. Concordance between the assays for detecting HIV-1 RNA ≥400 copies/mL was 95.8% (298/311). The sensitivity, specificity, positive predictive value and negative predictive value of Abbott to detect HIV-1 RNA ≥400 copies/mL were 91.8%, 100%, 100% and 92.2%, respectively. For the 151 samples with HIV-1 RNA ≥400 copies/mL for both assays, a good linear correlation was found (r = 0.81, P Abbott assay performed well in our setting, offering an alternative methodology for HIV-1 VL for laboratories with realtime polymerase chain reaction (PCR) capacity.

  8. Performance evaluation of new automated hepatitis B viral markers in the clinical laboratory: two quantitative hepatitis B surface antigen assays and an HBV core-related antigen assay.

    Science.gov (United States)

    Park, Yongjung; Hong, Duck Jin; Shin, Saeam; Cho, Yonggeun; Kim, Hyon-Suk

    2012-05-01

    We evaluated quantitative hepatitis B surface antigen (qHBsAg) assays and a hepatitis B virus (HBV) core-related antigen (HBcrAg) assay. A total of 529 serum samples from patients with hepatitis B were tested. HBsAg levels were determined by using the Elecsys (Roche Diagnostics, Indianapolis, IN) and Architect (Abbott Laboratories, Abbott Park, IL) qHBsAg assays. HBcrAg was measured by using Lumipulse HBcrAg assay (Fujirebio, Tokyo, Japan). Serum aminotransferases and HBV DNA were respectively quantified by using the Hitachi 7600 analyzer (Hitachi High-Technologies, Tokyo, Japan) and the Cobas AmpliPrep/Cobas TaqMan test (Roche). Precision of the qHBsAg and HBcrAg assays was assessed, and linearity of the qHBsAg assays was verified. All assays showed good precision performance with coefficients of variation between 4.5% and 5.3% except for some levels. Both qHBsAg assays showed linearity from 0.1 to 12,000.0 IU/mL and correlated well (r = 0.9934). HBsAg levels correlated with HBV DNA (r = 0.3373) and with HBcrAg (r = 0.5164), and HBcrAg also correlated with HBV DNA (r = 0.5198; P < .0001). This observation could provide impetus for further research to elucidate the clinical usefulness of the qHBsAg and HBcrAg assays.

  9. Infección oculta por el virus de la hepatitis B en hijos de madres positivas al HBsAg

    Directory of Open Access Journals (Sweden)

    Marité Bello-Corredor

    2016-04-01

    Full Text Available La infección oculta por el virus de la hepatitis B (IOB, se caracteriza por la presencia en suero o plasma del genoma viral (ADN-VHB y anticuerpos contra la proteína de la cápside (anti-HBc en ausencia del antígeno de superficie (HBsAg, marcador que tradicionalmente se emplea para identificar la presencia del virus. Con el objetivo de caracterizar la presencia de IOB en hijos de madres positivas al HBsAg, se estudiaron 291 muestras séricas de niños con la condición de ser HBsAg (- y anticuerpos anti-HBsAg (anti-HBs menores de 50 UI/L, conservadas en la seroteca del Laboratorio de Referencia Nacional de Hepatitis Virales. Se realizaron ensayos para determinar la exposición al virus (anti-HBc, a los sueros anti-HBc (+ se les realizó Reacción en Cadena de la Polimerasa en Tiempo Real (RCP-TR para determinar y cuantificar el ADN-VHB. La prevalencia de exposición al VHB (anti-HBc fue 16,8% (49/291. El ADN viral se cuantificó en el 14% (6/43 de los casos anti-HBc (+, observándose cargas virales que oscilaban entre 2,15 x 101 hasta 3,42 x 101 UI/mL. La prevalencia de la IOB para el total de los pacientes analizados fue 2,1% (6/291, considerada relativamente baja. No se encontró asociación significativa entre las variables sociodemográficas analizadas tales como: edad, sexo y provincia de procedencia. La IOB está presente en hijos de madres positivas al HBsAg, a pesar de la profilaxis contra la hepatitis B. Por lo tanto, se requiere de pesquisajes adecuados para detectar dicha entidad. Las implicaciones clínicas y epidemiológicas de la misma, requieren de un estrecho monitoreo y atención de estos pacientes. Este estudio se realiza por primera vez en Cuba y aporta conocimientos útiles para el diagnóstico, prevención y control de esta enfermedad en niños.

  10. Reproducibility Problems with the Abbott Laboratories LCx Assay for Chlamydia trachomatis and Neisseria gonorrhoeae

    OpenAIRE

    Gronowski, Ann M.; Copper, Susan; Baorto, David; Murray, Patrick R.

    2000-01-01

    This study demonstrates that significant reproducibility problems can occur during routine use of the Abbott Laboratories LCx assay for Chlamydia trachomatis and Neisseria gonorrhoeae. These problems can go undetected by the quality control procedures outlined in the manufacturer's package insert. We outline here procedures for detecting and preventing contamination and reproducibility problems.

  11. Early Childhood Education: The Sustainability of the Benefits of Preschool Participation in Abbott Districts

    Science.gov (United States)

    Fernandez, Norma

    2010-01-01

    The landmark New Jersey Supreme Court school funding case, "Abbott v. Burke", established the availability of preschool for all three- and four-year-olds living within the state's thirty-one poorest districts as a means of eradicating the effects of poverty. Longitudinal studies have shown the value of high quality preschool programs for…

  12. Performance evaluation of a particle-enhanced turbidimetric cystatin C assay on the Abbott ci8200 analyzer.

    Science.gov (United States)

    Flodin, Mats; Larsson, Anders

    2009-06-01

    Glomerular filtration rate (GFR) is widely accepted as the best overall measure of kidney function. Cystatin C is a novel endogenous GFR marker that has been shown to be superior to creatinine for estimation of GFR in several studies. There is a need for cystatin C assays adapted to routine chemistry instrument to minimize turnaround times and allowing 24 h/day availability. We have evaluated a new cystatin C assay developed for Architect cSystem (Abbott Laboratories, Abbott Park, IL, USA). The cystatin C assay showed good agreement with the corresponding assay from Dade Behring (Deerfield, IL, USA). The assay has a very low total imprecision and a good linearity. The new cystatin C assay is an interesting alternative to current cystatin C assays. On an Architect cSystem the assay can be performed with the same turnaround times and availability as creatinine.

  13. Physical optics modeling of modal patterns in a crossed porro prism resonator

    CSIR Research Space (South Africa)

    Litvin, IA

    2006-07-01

    Full Text Available A physical optics model is proposed to describe the transverse modal patterns in crossed Porro prism resonators. The model departs from earlier attempts in that the prisms are modeled as non-classical rotating elements with amplitude and phase...

  14. Os experimentos prismáticos de Goethe Goethe's prismatic experiments

    Directory of Open Access Journals (Sweden)

    Fred Jordan

    1993-12-01

    Full Text Available O ensaio pretende estimular a realização de experimentos prismáticos com recursos muito simples e, com isso, facilitar o acesso aos fundamentais estudos de Goethe sobre cor, a "Farbenlehre". O encarte anexo contém fotos de um processo prismático complementar, produzido por Imagens-Modelo em Claro-Escuro neutro. Contém ainda fotos de imagens prismáticas produzidas por Imagens-Modelo em cores.The essay intends to stimulate the carrying out of prismatic experiments with very simple resources and, therewith, ease the access to Goethe's fundamental color studies, the "Farbenlehre". The included folder contains photographs of a complementary prismatic process produced by neutral bright-dark Model-Images. It also contains photographs of prismatic images produced by colored Model-Images.

  15. Beam pointing direction changes in a misaligned Porro prism resonator

    Science.gov (United States)

    Lee, Jyh-Fa; Leung, Chung-Yee

    1988-07-01

    The relative change of the beam pointing direction for a misaligned Porro prism resonator has been analyzed, using an oscillation axis concept for the Porro prism resonator to find the beam direction. Expressions for the beam tilting angles are presented which show that the angular misalignment in the horizontal direction will result in beam tilting in both the horizontal and vertical directions. Good agreement between experimental and theoretical results is found.

  16. Improvement of Mental Imagery after Prism Exposure in Neglect: A Case Study

    Directory of Open Access Journals (Sweden)

    Gilles Rode

    1999-01-01

    Full Text Available Previous work has shown that various symptoms of unilateral neglect, including the pathological shift of the subjective midline to the right, may be improved by a short adaptation period to a prismatic shift of the visual field to the right. We report here the improvement of imagined neglect after prism exposure in a patient with a left unilateral neglect. Despite a strong neglect observed for mental images as well as for conventional tests, the mental evocation of left-sided information from an internal image of the map of France map was fully recovered following prism adaptation to the right. This improvement could not be explained by the alteration of visuomotor responses induced by the prism adaptation. Prism adaptation may therefore act not only on sensory-motor levels but also on a higher cognitive level of mental space representation and/or exploration.

  17. Fault structure, properties and activity of the Makran Accretionary Prism and implications for seismogenic potential

    Science.gov (United States)

    Smith, G. L.; McNeill, L. C.; Henstock, T.; Bull, J. M.

    2011-12-01

    The Makran subduction zone is the widest accretionary prism in the world (~400km), generated by convergence between the Arabian and Eurasian tectonic plates. It represents a global end-member, with a 7km thick incoming sediment section. Accretionary prisms have traditionally been thought to be aseismic due to the presence of unconsolidated sediment and elevated basal pore pressures. The seismogenic potential of the Makran subduction zone is unclear, despite a Mw 8.1 earthquake in 1945 that may have been located on the plate boundary beneath the prism. In this study, a series of imbricate landward dipping (seaward verging) thrust faults have been interpreted across the submarine prism (outer 70 km) using over 6000km of industry multichannel seismic data and bathymetric data. A strong BSR (bottom simulating reflector) is present throughout the prism (excluding the far east). An unreflective décollement is interpreted from the geometry of the prism thrusts. Two major sedimentary units are identified in the input section, the lower of which contains the extension of the unreflective décollement surface. Between 60%-100% of the input section is currently being accreted. The geometry of piggy-back basin stratigraphy shows that the majority of thrusts, including those over 50km from the trench, are recently active. Landward thrusts show evidence for reactivation after periods of quiescence. Negative polarity fault plane reflectors are common in the frontal thrusts and in the eastern prism, where they may be related to increased fault activity and fluid expulsion, and are rarer in older landward thrusts. Significant NE-SW trending basement structures (The Murray Ridge and Little Murray Ridge) on the Arabian plate intersect the deformation front and affect sediment input to the subduction zone. Prism taper and structure are apparently primarily controlled by sediment supply and the secondary influence of subducting basement ridges. The thick, likely distal, sediment

  18. Use of yoked prisms in patients with acquired brain injury: a retrospective analysis.

    Science.gov (United States)

    Bansal, Surbhi; Han, Esther; Ciuffreda, Kenneth J

    2014-01-01

    The purpose of this retrospective study was to determine the clinical practices for prescribing yoked prisms, as well as to assess related patient responses, in a sample of visually-symptomatic patients having acquired brain injury (ABI). The clinical records of individuals with acquired brain injury (ABI) that were assessed for yoked prisms were reviewed retrospectively. This query resulted in 60 patient records for analysis between January 2011 and December 2012. The following diagnostic groups were analysed: homonymous hemianopsia (HH)/homonymous quadranopsia, abnormal egocentric localization (AEL) and visual neglect. HH/homonymous quadranopsia (58.3%) was the primary indication to prescribe yoked prisms, followed by visual neglect/unilateral spatial inattention (USI) (40.0%) and AEL (11.7%). The most common favourable patient responses were increased awareness of their blind visual field and improved gait, mobility and balance. The magnitude and direction of prisms prescribed were dependent upon the subjective responses in patients manifesting AEL. In contrast, base direction was dependent upon the direction of visual field loss in patients with HH/homonymous quadranopsia and visual neglect. Two-thirds of the present sample population responded favourably to the yoked prisms. The results of the present study should prove useful to clinicians for the successful prescription of yoked prisms as a treatment modality in patients presenting with the above three diagnoses.

  19. Forward and inverse solutions for Risley prism based on the Denavit-Hartenberg methodology

    Science.gov (United States)

    Beltran-Gonzalez, A.; Garcia-Torales, G.; Strojnik, M.; Flores, J. L.; Garcia-Luna, J. L.

    2017-08-01

    In this work forward and inverse solutions for two-element Risley prism for pointing and scanning beam systems are developed. A more efficient and faster algorithm is proposed to make an analogy of the Risley prism system compared with a robotic system with two degrees of freedom. This system of equations controls each Risley prism individually as a planar manipulator arm of two links. In order to evaluate the algorithm we implement it in a pointing system. We perform popular routines such as the linear, spiral and loops traces. Using forward and inverse solutions for two-element Risley prism it is also possible to point at coordinates specified by the user, provided they are within the pointer area of work area. Experimental results are showed as a validation of our proposal.

  20. 75 FR 80061 - Abbott Laboratories, Inc.; Withdrawal of Approval of a New Drug Application for MERIDIA

    Science.gov (United States)

    2010-12-21

    ... withdrawing approval of a new drug application (NDA) for MERIDIA (sibutramine hydrochloride (HCl)) oral... requested that Abbott voluntarily withdraw MERIDIA (sibutramine HCl) oral capsules from the market, based on FDA's recent analysis of clinical trial data from the Sibutramine Cardiovascular Outcomes Trial (SCOUT...

  1. Correlation between HBsAg, prothrombin time activity, and indocyanine green retention rate at 15 minutes in patients with HBeAg-positive chronic HBV infection

    Directory of Open Access Journals (Sweden)

    FAN Wenhai

    2016-11-01

    Full Text Available ObjectiveTo investigate the correlation between HBsAg, prothrombin time activity (PTA, and indocyanine green retention rate at 15 minutes (ICG R15 in patients with HBeAg-positive chronic HBV infection. MethodsA total of 92 patients with HBeAg-positive chronic HBV infection who were admitted to The First Hospital of Lanzhou University from December 2015 to April 2016 were enrolled and divided into chronic hepatitis B (CHB group (24 patients, compensated liver cirrhosis group (38 patients, and decompensated liver cirrhosis group (30 patients. Serum HBsAg quantitation, PTA test, and liver reserve function test (ICG R15 were performed for all patients. The chi-square test was used for comparison of categorical data between groups, an analysis of variance was used for comparison of continuous data between multiple groups, and a Pearson correlation analysis was also performed. ResultsThere were significant differences between the three groups in serum HBsAg quantitation (3.82±0.43 log10IU/ml vs 2.88±0.36 log10IU/ml vs 2.60±0.27 log10IU/ml, F=25.19, P<0.001, ICG R15 (7.51%±3.10% vs 9.57%±8.18% vs 24.13%±14.28%, F=24.00, P=0.001, and PTA (8100%±1762% vs 83.08%±9.64% vs 62.32%±16.90%, F=13.42, P=0.009. The correlation analysis showed that PTA was negatively correlated with ICG R15 in all three groups (r=-0.948, -0.602, and -0.735, all P<0.01. In the compensated liver cirrhosis group and decompensated liver cirrhosis group, HBsAg was positively correlated with PTA (r=0.410 and 0.473, both P<0.05 and negatively correlated with ICG R15 (r=-0.427 and -0.768, P<0.01. ConclusionIn HBeAg positive patients, there are certain correlations between HBsAg, PTA, and ICG R15, which, to a certain degree, reflects the liver reserve function in patients with chronic HBV infection.

  2. Eu3+-doped Y2O3 hexagonal prisms: Shape-controlled synthesis and tailored luminescence properties

    International Nuclear Information System (INIS)

    Yang, Errui; Li, Guangshe; Fu, Chaochao; Zheng, Jing; Huang, Xinsong; Xu, Wen; Li, Liping

    2015-01-01

    In this work, Eu 3+ doped Y 2 O 3 hexagonal prisms were synthesized by a novel two-phase approach, which involves water at the bottom as aqueous phase and oleylamine in the above as oil phase. With this unique reaction system, precursors of hexagonal prisms Y 4 O(OH) 9 (NO 3 ) were first obtained by simply varying the volume ratio of water to oleylamine. Time-dependent experiments were systematically performed to reveal the growth mechanism of the precursor. After subsequent heat treatment, these precursors transformed to Y 2 O 3 hexagonal prisms with controlled diameters and aspect ratios varying from 4 to 19. Such a transformation is preceded via a topotactic process, as indicated by TG-DTA and mass spectra. Eventually, all Eu 3+ doped Y 2 O 3 hexagonal prisms were found to exhibit an intensive red emission at 611 nm, which corresponds to 5 D 0 → 7 F 2 transition of Eu 3+ . With varying the aspect ratio of hexagonal prisms and increasing Eu 3+ concentration in Y 2 O 3 , an optimum external quantum efficiency was achieved. - Graphical abstract: In this work, Eu 3+ doped Y 2 O 3 hexagonal prisms with controlled aspect ratio from 4.4 to 19.3 were synthesized by transformation of the precursor Y 4 O(OH) 9 (NO 3 ) hexagonal prisms from a novel two-phase reaction system. The growth mechanism of the precursor has been systematically investigated, and a topotactic phase transformation from precursors to cubic Y 2 O 3 is for the first time put forward. By the size controlling and aspect ratio adjusting, the luminescence emission intensity as well as external quantum efficiency of Eu 3+ doped Y 2 O 3 hexagonal prisms is further tailored to show an optimum. - Highlights: • Eu 3+ doped Y 2 O 3 hexagonal prisms were synthesized by a novel two-phase approach. • Inheriting mechanism of prisms morphology from Y 4 O(OH) 9 (NO 3 ) to Y 2 O 3 was discussed. • Aspect ratio of prisms was tailored by the volume ratio of water to oleylamine. • Luminescence properties were

  3. Design and optical analyses of an arrayed microfluidic tunable prism panel for enhancing solar energy collection

    International Nuclear Information System (INIS)

    Narasimhan, Vinayak; Jiang, Dongyue; Park, Sung-Yong

    2016-01-01

    Highlights: • We present an arrayed tunable prism panel enabling wide tracking and high solar concentration. • A microfluidic technology allows a low-cost, lightweight and precise solar tracking system. • Our prism panel enables high solar concentration up to 2032× factor. • Various liquid prism configurations (stacked prism arrays) and optical materials are considered. • Their impacts on solar beam steering, reflection losses and beam concentration are studied. - Abstract: We present the design and optical analyses of an arrayed microfluidic tunable prism panel that enables wide solar tracking and high solar concentration while minimizing energy loss. Each of the liquid prism modules is implemented by a microfluidic (i.e. non-mechanical) technology based on electrowetting for adaptive solar beam steering. Therefore the proposed platform offers a low-cost, lightweight and precise solar tracking system while obviating the need for bulky and heavy mechanical moving parts essentially required for a conventional motor-driven solar tracker. In this paper, various liquid prism configurations in terms of design (single, double, triple and quad-stacked prism arrays) as well as optical materials are considered and their impact on optical performance aspects such as solar beam steering, reflection losses and beam concentration is studied. Our system is able to achieve a wide solar tracking covering the whole-day movement of the Sun and a reflection loss below 4.4% with a Rayleigh’s film for a quad-stacked prism configuration. Furthermore, an arrayed prism panel is proposed to increase the aperture area and thus allows for the collection of large amounts of sunlight. Our simulation study based on the optical design software, ZEMAX, indicates that the prism panel is capable of high solar concentration up to 2032× factor even without conventional solar tracking devices. We also deal with dispersion characteristics of the materials and their corresponding effect on

  4. PRISM, a Novel Visual Metaphor Measuring Personally Salient Appraisals, Attitudes and Decision-Making: Qualitative Evidence Synthesis.

    Directory of Open Access Journals (Sweden)

    Tom Sensky

    Full Text Available PRISM (the Pictorial Representation of Illness and Self Measure is a novel, simple visual instrument. Its utility was initially discovered serendipitously, but has been validated as a quantitative measure of suffering. Recently, new applications for different purposes, even in non-health settings, have encouraged further exploration of how PRISM works, and how it might be applied. This review will summarise the results to date from applications of PRISM and propose a generic conceptualisation of how PRISM works which is consistent with all these applications.A systematic review, in the form of a qualitative evidence synthesis, was carried out of all available published data on PRISM.Fifty-two publications were identified, with a total of 8254 participants. Facilitated by simple instructions, PRISM has been used with patient groups in a variety of settings and cultures. As a measure of suffering, PRISM has, with few exceptions, behaved as expected according to Eric Cassell's seminal conceptualisation of suffering. PRISM has also been used to assess beliefs about or attitudes to stressful working conditions, interpersonal relations, alcohol consumption, and suicide, amongst others.This review supports PRISM behaving as a visual metaphor of the relationship of objects (eg 'my illness' to a subject (eg 'myself' in a defined context (eg 'my life at the moment'. As a visual metaphor, it is quick to complete and yields personally salient information. PRISM is likely to have wide applications in assessing beliefs, attitudes, and decision-making, because of its properties, and because it yields both quantitative and qualitative data. In medicine, it can serve as a generic patient-reported outcome measure. It can serve as a tool for representational guidance, can be applied to developing strategies visually, and is likely to have applications in coaching, psychological assessment and therapeutic interventions.

  5. Performance evaluation of the QIAGEN EZ1 DSP Virus Kit with Abbott RealTime HIV-1, HBV and HCV assays.

    Science.gov (United States)

    Schneider, George J; Kuper, Kevin G; Abravaya, Klara; Mullen, Carolyn R; Schmidt, Marion; Bunse-Grassmann, Astrid; Sprenger-Haussels, Markus

    2009-04-01

    Automated sample preparation systems must meet the demands of routine diagnostics laboratories with regard to performance characteristics and compatibility with downstream assays. In this study, the performance of QIAGEN EZ1 DSP Virus Kit on the BioRobot EZ1 DSP was evaluated in combination with the Abbott RealTime HIV-1, HCV, and HBV assays, followed by thermalcycling and detection on the Abbott m2000rt platform. The following performance characteristics were evaluated: linear range and precision, sensitivity, cross-contamination, effects of interfering substances and correlation. Linearity was observed within the tested ranges (for HIV-1: 2.0-6.0 log copies/ml, HCV: 1.3-6.9 log IU/ml, HBV: 1.6-7.6 log copies/ml). Excellent precision was obtained (inter-assay standard deviation for HIV-1: 0.06-0.17 log copies/ml (>2.17 log copies/ml), HCV: 0.05-0.11 log IU/ml (>2.09 log IU/ml), HBV: 0.03-0.07 log copies/ml (>2.55 log copies/ml)), with good sensitivity (95% hit rates for HIV-1: 50 copies/ml, HCV: 12.5 IU/ml, HBV: 10 IU/ml). No cross-contamination was observed, as well as no negative impact of elevated levels of various interfering substances. In addition, HCV and HBV viral load measurements after BioRobot EZ1 DSP extraction correlated well with those obtained after Abbott m2000sp extraction. This evaluation demonstrates that the QIAGEN EZ1 DSP Virus Kit provides an attractive solution for fully automated, low throughput sample preparation for use with the Abbott RealTime HIV-1, HCV, and HBV assays.

  6. Transfer of memory trace of cerebellum-dependent motor learning in human prism adaptation: a model study.

    Science.gov (United States)

    Nagao, Soichi; Honda, Takeru; Yamazaki, Tadashi

    2013-11-01

    Accumulating experimental evidence suggests that the memory trace of ocular reflex adaptation is initially encoded in the cerebellar cortex, and later transferred to the cerebellar nuclei for consolidation through repetitions of training. However, the memory transfer is not well characterized in the learning of voluntary movement. Here, we implement our model of memory transfer to interpret the data of prism adaptation (Martin, Keating, Goodkin, Bastian, & Thach, 1996a, 1996b), assuming that the cerebellar nuclear memory formed by memory transfer is used for normal throwing. When the subject was trained to throw darts wearing prisms in 30-40 trials, the short-term memory for recalibrating the throwing direction by gaze would be formed in the cerebellar cortex, which was extinguished by throwing with normal vision in a similar number of trials. After weeks of repetitions of short-term prism adaptation, the long-term memory would be formed in the cerebellar nuclei through memory transfer, which enabled one to throw darts to the center wearing prisms without any training. These two long-term memories, one for throwing with normal vision and the other for throwing wearing prisms, are assumed to be utilized automatically under volitional control. Moreover, when the prisms were changed to new prisms, a new memory for adapting to the new prisms would be formed in the cerebellar cortex, just to counterbalance the nuclear memory of long-term adaptation to the original prisms in a similar number of trials. These results suggest that memory transfer may occur in the learning of voluntary movements. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. XeCl excimer laser with new prism resonator configurations and its performance characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Benerji, N. S., E-mail: nsb@rrcat.gov.in, E-mail: bsingh@rrcat.gov.in; Singh, A.; Varshnay, N.; Singh, Bijendra, E-mail: nsb@rrcat.gov.in, E-mail: bsingh@rrcat.gov.in [Excimer Laser Section, LMPD, Raja Ramanna Center for Advanced Technology, Indore 452013 (India)

    2015-07-15

    New resonator cavity configurations, namely, the prism resonator and unstable prism resonator, are demonstrated for the first time in an excimer (XeCl) laser with interesting and novel results. High misalignment tolerance ∼50 mrad is achieved with considerably reduced beam divergence of less than ∼1 mrad without reduction in output power capabilities of the laser. The misalignment tolerance of ∼50 mrad is a dramatic improvement of ∼25 times compared to ∼2 mrad normally observed in standard excimer laser with plane-plane cavity. Increase in depth of focus from 3 mm to 5.5 mm was also achieved in case of prism resonator configuration with an improvement of about 60%. Unstable prism resonator configuration is demonstrated here in this paper with further reduction in beam divergence to about 0.5 mrad using plano-convex lens as output coupler. The misalignment tolerance in case of unstable prism resonator was retained at about 30 mrad which is a high value compared to standard unstable resonators. The output beam spot was completely filled with flat-top profile with prism resonator configurations, which is desired for various material processing applications. Focusing properties and beam divergence in case of prism resonator have been investigated using SEM (scanning electron microscope) images. SEM images of the focused spot size (∼20 μm holes) on metal sheet indicate beam divergence of about 0.05 mrad which is about 1.5 times diffraction limit. Energy contained in this angle is thus sufficient for micro-machining applications. Clean and sharp edges of the micro-holes show high pointing stability with multiple shot exposures. Such characteristics of the excimer laser system will be extremely useful in micro-machining and other field applications.

  8. Jones matrix formulation of a Porro prism laser resonator with waveplates: theoretical and experimental analysis

    Science.gov (United States)

    Agrawal, L.; Bhardwaj, A.; Pal, S.; Kumar, A.

    2007-11-01

    This article presents the results of a detailed theoretical and experimental analysis carried out on a folded Z-shaped polarization coupled, electro-optically Q-switched laser resonator with Porro prisms and waveplates. The advantages of adding waveplates in a Porro prism resonator have been explored for creating high loss condition prior to Q-switching and obtaining variable reflectivity with fixed orientation of Porro prism. Generalized expressions have been derived in terms of azimuth angles and phase shifts introduced by the polarizing elements. These expressions corroborate with known reported results under appropriate substitutions. A specific case of a crossed Porro prism diode-pumped Nd:YAG laser has been theoretically and experimentally investigated. In the feedback arm, a 0.57λ waveplate oriented at 135° completely compensates the phase shift of a fused silica Porro prism and provides better tolerances than a BK-7 prism/0.60λ waveplate combination to stop prelasing. The fused silica prism/0.57λ combination with waveplate at 112° acts like a 100% mirror and was utilized for optimization of free running performance. The effective reflectivity was determined for various orientations of the quarter waveplate in the gain arm to numerically estimate the Q-switched laser pulse parameters through rate equation analysis. Experimental results match well with the theoretical analysis.

  9. Beyond the sensorimotor plasticity: cognitive expansion of prism adaptation in healthy individuals.

    Directory of Open Access Journals (Sweden)

    Carine eMICHEL

    2016-01-01

    Full Text Available Sensorimotor plasticity allows us to maintain an efficient motor behavior in reaction to environmental changes. One of the classical models for the study of sensorimotor plasticity is prism adaptation. It consists of pointing to visual targets while wearing prismatic lenses that shift the visual field laterally. The conditions of the development of the plasticity and the sensorimotor after-effects have been extensively studied for more than a century. However, the interest taken in this phenomenon was considerably increased since the demonstration of neglect rehabilitation following prism adaptation by Rossetti and his colleagues in 1998. Mirror effects, i.e. simulation of neglect in healthy individuals, were observed for the first time by Colent and collaborators in 2000. The present review focuses on the expansion of prism adaptation to cognitive functions in healthy individuals during the last 15 years. Cognitive after-effects have been shown in numerous tasks even in those that are not intrinsically spatial in nature. Altogether, these results suggest the existence of a strong link between low-level sensorimotor plasticity and high-level cognitive functions and raise important questions about the mechanisms involved in producing unexpected cognitive effects following prism adaptation. Implications for the functional mechanisms and neuroanatomical network of prism adaptation are discussed to explain how sensorimotor plasticity may affect cognitive processes.

  10. [Contribution of HCV core antigen testing in HCV diagnosis by test from the company Abbott Laboratories].

    Science.gov (United States)

    Trbusek, J

    2009-11-01

    Detection of HCV core antigen as direct marker of hepatitis C infection clearly improves diagnosis of this disease (especially reduction of window period) and brings broad clinical utilization. The company Abbott Laboratories offers fully automated laboratory test for measurement of HCV core antigen on ARCHITECT analyzers.

  11. Innovative Solar Tracking Concept by Rotating Prism Array

    Directory of Open Access Journals (Sweden)

    Héctor García

    2014-01-01

    Full Text Available Solar energy has become one of the most promising renewable energies and is the most widely used nowadays. In order to achieve an optimum performance, both photovoltaic and solar thermal applications are required to track the position of the sun throughout the day and year in the most effective way possible to avoid a high negative impact on the system efficiency. The present paper attempts to describe a novel semipassive solar tracking concentrator (SPSTC in which, in order to track the sun, two independent arrays of polymethyl methacrylate (PMMA prisms are implemented to refract sunlight by rotating said prisms, thus being able to redirect solar radiation as desired. The first set is responsible for eliminating one of the directional components of the solar radiation; the task is achieved by rotating the prisms within the array at a specific angle. The second set deals with another of the sunlight’s directional components, transforming its direction into a completely perpendicular pattern to the array. Having downward vertical radiation makes it possible to implement a stationary Fresnel lens to concentrate the solar radiation for any application desired. The system is designed and validated using simulation software to prove the feasibility of the concept.

  12. Comparing Volumes of Prisms and Pyramids

    Science.gov (United States)

    Vinogradova, Natalya

    2012-01-01

    Students' experience in using formulas for volumes is often limited to substituting numbers into given formulas. An activity presented in this article may help students make connections between the formulas for volumes of prisms and volumes of pyramids. In addition, some interesting facts from number theory arise, demonstrating strong connections…

  13. Anomalous refraction of light colors by a metamaterial prism.

    Science.gov (United States)

    Silveirinha, Mário G

    2009-05-15

    A prism of glass separates white light into its spectral components in such a manner that colors associated with shorter wavelengths are more refracted than the colors associated with longer wavelengths. Here, we demonstrate that this property is not universal, and that a lossless metamaterial prism with a suitable microstructure may enable a broadband regime of anomalous dispersion, where the spectral components of light are separated in an unconventional way, so that "violet light" is less refracted than "red light." This phenomenon is fundamentally different from conventional anomalous dispersion effects, which are invariably accompanied by significant loss and are typically very narrow band.

  14. Multi-site analytical evaluation of the Abbott ARCHITECT tacrolimus assay.

    Science.gov (United States)

    Wallemacq, Pierre; Goffinet, Jean-Sebastien; O'Morchoe, Susan; Rosiere, Thomas; Maine, Gregory T; Labalette, Myriam; Aimo, Giuseppe; Dickson, Diana; Schmidt, Ed; Schwinzer, Reinhard; Schmid, Rainer W

    2009-04-01

    The objective of this study was to evaluate the analytical performance of the Abbott ARCHITECT Tacrolimus immunoassay. Proficiency panels and specimens from a population of organ transplant recipients were analyzed in 6 clinical laboratories in Europe and the United States, and the results were compared with other methods. The ARCHITECT assay requires a whole blood specimen pretreatment step with methanol/zinc sulfate to precipitate protein and extract the drug, followed by a 30-minute immunoassay using anti-tacrolimus antibody-coated paramagnetic microparticles and an acridinium-tacrolimus tracer. The assay was free from hematocrit interference in the range 25%-55% and from interference by extremes of cholesterol, triglycerides, bilirubin, total protein, and uric acid. The total percent of coefficient of variations of the assay were 4.9%-7.6% at 3 ng/mL, 2.9%-4.6% at 8.6 ng/mL, and 3.1%-8.2% at 15.5 ng/mL. Limit of detection was Abbott IMx Tacrolimus II immunoassay (4 sites) yielded average biases between -0.94 and +0.26 ng/mL; ARCHITECT assay versus the Dade Dimension Tacrolimus immunoassay (2 sites) yielded average biases of -0.46 and +0.11 ng/mL; and ARCHITECT assay versus LC-MSMS methods at 2 sites yielded average biases of +0.51 and +1.63 ng/mL. Spearman correlation coefficients were >/=0.90 on all method comparisons. The ARCHITECT Tacrolimus assay is a semiautomated, robust, and highly sensitive immunoassay, representing an alternative approach for laboratories not equipped with LC-MSMS, and meets the 1 ng/mL recommendation of LOQ by the European Consensus Conference on Tacrolimus Optimization.

  15. Corporate Privacy Policy Changes during PRISM and the Rise of Surveillance Capitalism

    Directory of Open Access Journals (Sweden)

    Priya Kumar

    2017-03-01

    Full Text Available Disclosure of the NSA’s PRISM program demonstrated that Internet companies have become prime targets of government surveillance. But what role do companies themselves play in putting users’ privacy at risk? By comparing the changes in the privacy policies of ten companies—the nine in PRISM plus Twitter—I seek to understand how users’ privacy shifted. Specifically, I study how company practices surrounding the life cycle of user information (e.g. collection, use, sharing, and retention shifted between the times when companies joined PRISM and when PRISM news broke. A qualitative analysis of the changes in the privacy policies suggests that company disclosure of tracking for advertising purposes increased. I draw on business scholar Shoshana Zuboff’s conceptualization of “surveillance capitalism” and legal scholar Joel Reidenberg’s “transparent citizen” to explain the implications such changes hold for users’ privacy. These findings underscore why public debates about post-Snowden privacy rights cannot ignore the role that companies play in legitimizing surveillance activities under the auspices of creating market value.

  16. Compact, semi-passive beam steering prism array for solar concentrators.

    Science.gov (United States)

    Zheng, Cheng; Li, Qiyuan; Rosengarten, Gary; Hawkes, Evatt; Taylor, Robert A

    2017-05-10

    In order to maximize solar energy utilization in a limited space (e.g., rooftops), solar collectors should track the sun. As an alternative to rotational tracking systems, this paper presents a compact, semi-passive beam steering prism array which has been designed, analyzed, and tested for solar applications. The proposed prism array enables a linear concentrator system to remain stationary so that it can integrate with a variety of different solar concentrators, and which should be particularly useful for systems which require a low profile (namely rooftop-mounted systems). A case study of this prism array working within a specific rooftop solar collector demonstrates that it can boost the average daily optical efficiency of the collector by 32.7% and expand its effective working time from 6 h to 7.33 h. Overall, the proposed design provides an alternative way to "follow" the sun for a wide range of solar thermal and photovoltaic concentrator systems.

  17. Fusional Vergence Detected by Prism Bar and Synoptophore in Chinese Childhood Intermittent Exotropia

    Directory of Open Access Journals (Sweden)

    Tao Fu

    2015-01-01

    Full Text Available Purpose. To measure the changes in fusional vergence in Chinese children with intermittent exotropia (IXT and the association with the control of IXT. Methods. Ninety-two patients with IXT (8–15 years old were compared with 86 controls. Exodeviation control was evaluated using the Revised Newcastle Control Score. Angle of deviation was measured using prism and alternate cover testing at distance and near. Fusional vergence was measured using prism bar and synoptophore. This study was registered with ChiCTR-RCC-13003920. Results. Using prism bar, convergence break points were lower whereas divergence break points were higher in children with IXT at distance (P<0.001 and near (P<0.001 compared with controls. There was no significant difference in mean divergence amplitudes between the two groups when testing using a synoptophore (P=0.53. In children with IXT, the distance between recovery point and break point in both convergence (distance: P=0.02; near: P=0.02 and divergence (distance: P<0.001; near: P<0.001 was larger than controls when detected by prism bar and synoptophore (convergence: P=0.005; divergence: P=0.006. Conclusions. Children with IXT have reduced convergence amplitudes as detected by both prism bar and synoptophore.

  18. Comparison of the clinical performances of the AdvanSure HPV Screening Real-Time PCR, the Abbott Real-Time High-Risk HPV Test, and the Hybrid Capture High-Risk HPV DNA Test for Cervical Cancer Screening.

    Science.gov (United States)

    Chung, Hae-Sun; Hahm, Chorong; Lee, Miae

    2014-09-01

    The clinical performance of three human papillomavirus (HPV) DNA commercial assays for cervical cancer screening was evaluated; the AdvanSure HPV Screening Real-Time PCR (AdvanSure PCR; LG Life Sciences) that was developed recently for the detection of both high-risk and low-risk genotypes, the Abbott RealTime High-Risk HPV Test (Abbott PCR; Abbott Molecular) and the Hybrid Capture High-Risk HPV DNA test (HC2; Qiagen). The three different HPV DNA tests were compared using cytology samples obtained from 619 women who underwent routine cervical cancer screening. The gold-standard assay was histopathological confirmation of cervical intraepithelial neoplasia of grade 2 or worse. The clinical sensitivities of the AdvanSure PCR, the Abbott PCR and the HC2 for the detection of cervical intraepithelial neoplasia of grade 2 or worse were 95.5%, 95.5% and 100%, respectively, while the clinical specificities were 61.6%, 86.4% and 83.3%, respectively. There were no significant differences in the clinical sensitivities of the Abbott PCR and the AdvanSure PCR compared to the HC2. The clinical specificities of the Abbott PCR and the AdvanSure PCR for the detection of HPV types 16/18 were 97.8% and 98.5%, respectively. For cervical cancer screening, all three tests showed relatively good clinical sensitivities, but the AdvanSure PCR had lower clinical specificity than the Abbott PCR and the HC2. The AdvanSure PCR and the Abbott PCR assays have the advantage of being automated and the ability to distinguish between HPV types 16/18 and other HPV types. The two real-time PCR assays could be useful tools in HPV testing for cervical cancer screening. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Analytical and clinical performance characteristics of the Abbott RealTime MTB RIF/INH Resistance, an assay for the detection of rifampicin and isoniazid resistant Mycobacterium tuberculosis in pulmonary specimens.

    Science.gov (United States)

    Kostera, Joshua; Leckie, Gregor; Tang, Ning; Lampinen, John; Szostak, Magdalena; Abravaya, Klara; Wang, Hong

    2016-12-01

    Clinical management of drug-resistant tuberculosis patients continues to present significant challenges to global health. To tackle these challenges, the Abbott RealTime MTB RIF/INH Resistance assay was developed to accelerate the diagnosis of rifampicin and/or isoniazid resistant tuberculosis to within a day. This article summarizes the performance of the Abbott RealTime MTB RIF/INH Resistance assay; including reliability, analytical sensitivity, and clinical sensitivity/specificity as compared to Cepheid GeneXpert MTB/RIF version 1.0 and Hain MTBDRplus version 2.0. The limit of detection (LOD) of the Abbott RealTime MTB RIF/INH Resistance assay was determined to be 32 colony forming units/milliliter (cfu/mL) using the Mycobacterium tuberculosis (MTB) strain H37Rv cell line. For rifampicin resistance detection, the Abbott RealTime MTB RIF/INH Resistance assay demonstrated statistically equivalent clinical sensitivity and specificity as compared to Cepheid GeneXpert MTB/RIF. For isoniazid resistance detection, the assay demonstrated statistically equivalent clinical sensitivity and specificity as compared to Hain MTBDRplus. The performance data presented herein demonstrate that the Abbott RealTime MTB RIF/INH Resistance assay is a sensitive, robust, and reliable test for realtime simultaneous detection of first line anti-tuberculosis antibiotics rifampicin and isoniazid in patient specimens. Copyright © 2016 The Author. Published by Elsevier Ltd.. All rights reserved.

  20. Train integrity detection risk analysis based on PRISM

    Science.gov (United States)

    Wen, Yuan

    2018-04-01

    GNSS based Train Integrity Monitoring System (TIMS) is an effective and low-cost detection scheme for train integrity detection. However, as an external auxiliary system of CTCS, GNSS may be influenced by external environments, such as uncertainty of wireless communication channels, which may lead to the failure of communication and positioning. In order to guarantee the reliability and safety of train operation, a risk analysis method of train integrity detection based on PRISM is proposed in this article. First, we analyze the risk factors (in GNSS communication process and the on-board communication process) and model them. Then, we evaluate the performance of the model in PRISM based on the field data. Finally, we discuss how these risk factors influence the train integrity detection process.

  1. Analysis of unscrammed loss of flow and heat sink for PRISM with GEM

    International Nuclear Information System (INIS)

    Slovik, G.C.; Van Tuyle, G.J.; Kennett, R.J.

    1991-01-01

    The US Department of Energy is sponsoring an advanced liquid-metal reactor design by General Electric Company (GE) called PRISM. The intent is to design a reactor with passively safe responses to many operational and severe accidents. PRISM is under review at the US Nuclear Regulatory Commission for licensability with Brookhaven National Laboratory providing technical assistance. Recently, the PRISM design has been modified to include three gas expansion modules (GEMs) on its core periphery. The GEMs were added to quickly reduce the power (by inserting negative reactivity) during loss-of-flow events to curtail peak fuel and clad temperatures predicted in the previous design. The GEM prototypes have been tested at the Fast Flux Test Facility. The significance of the GEMs in PRISM is discussed in this paper through the evaluation of the unprotected loss of flow (ULOF) and loss of heat sink using the SSC code. It has been demonstrated in the past that SSC predicts results similar to GE and other liquid-metal reactor codes

  2. Massive venlafaxine overdose resulted in a false positive Abbott AxSYM (R) urine immunoassay for phencyclidine

    NARCIS (Netherlands)

    Bond, GR; Steele, PE; Uges, DRA

    2003-01-01

    Case report: A 13-yr-old girl overdosed on 48 x 150 mg venlafaxine (Effexor XR(R)). She was taking venlafaxine regularly for depression. Her only other medications included topical Benzamycin and pyridoxine 50 mg daily for acne. The Abbott AxSYM(R) assay was positive only for phencyclidine, but

  3. Economic assessment of S-prism including development and generating costs

    Energy Technology Data Exchange (ETDEWEB)

    Boardman, Ch.E. [GE Nuclear Energy San Jose (United States)

    2001-07-01

    S-PRISM is an advanced Fast Reactor plant design that utilizes compact modular pool-type reactors sized to enable factory fabrication and an affordable prototype test of a single Nuclear Steam Supply System (NSSS) for design certification at minimum cost and risk. S-PRISM retains all of the key ALMR (advanced liquid metal reactor) design features including passive reactor shutdown, passive shutdown heat removal, and passive reactor cavity cooling that were developed under an earlier DOE program. Key factors that make S-PRISM competitive include: 1) The use of passive safety systems that eliminate the need for diesel generators and hardened active heat sinks to assure that sufficient heat is removed from the core, reactor, and containment systems following design and beyond design basis events. 2) A seven point advantage in the plant capacity factor (93 versus 86%) over a single large plant. 3) A much shorter construction schedule (45%) made possible by a modular design that allows near parallel (sequenced) construction of three relatively small, simple factory fabricated NSSSs instead of one large complex NSSS. This paper describes the approach, methods, and results of an in-depth economic assessment of S-PRISM. The assessment found that the generation cost from an NOAK plant would be less than 3 cents/kW-hr and that a design certification could be obtained in less than 15 years at a cost of 2.1 billion dollars. (authors)

  4. Economic assessment of S-prism including development and generating costs

    International Nuclear Information System (INIS)

    Boardman, Ch.E.

    2001-01-01

    S-PRISM is an advanced Fast Reactor plant design that utilizes compact modular pool-type reactors sized to enable factory fabrication and an affordable prototype test of a single Nuclear Steam Supply System (NSSS) for design certification at minimum cost and risk. S-PRISM retains all of the key ALMR (advanced liquid metal reactor) design features including passive reactor shutdown, passive shutdown heat removal, and passive reactor cavity cooling that were developed under an earlier DOE program. Key factors that make S-PRISM competitive include: 1) The use of passive safety systems that eliminate the need for diesel generators and hardened active heat sinks to assure that sufficient heat is removed from the core, reactor, and containment systems following design and beyond design basis events. 2) A seven point advantage in the plant capacity factor (93 versus 86%) over a single large plant. 3) A much shorter construction schedule (45%) made possible by a modular design that allows near parallel (sequenced) construction of three relatively small, simple factory fabricated NSSSs instead of one large complex NSSS. This paper describes the approach, methods, and results of an in-depth economic assessment of S-PRISM. The assessment found that the generation cost from an NOAK plant would be less than 3 cents/kW-hr and that a design certification could be obtained in less than 15 years at a cost of 2.1 billion dollars. (authors)

  5. Prism Foil from an LCD Monitor as a Tool for Teaching Introductory Optics

    Science.gov (United States)

    Planinsic, Gorazd; Gojkosek, Mihael

    2011-01-01

    Transparent prism foil is part of a backlight system in LCD monitors that are widely used today. This paper describes the optical properties of the prism foil and several pedagogical applications suitable for undergraduate introductory physics level. Examples include experiments that employ refraction, total internal reflection, diffraction and…

  6. Assessment of prism responses to loss of flow events

    International Nuclear Information System (INIS)

    Slovik, G.C.; Van Tuyle, G.J.; Sands, S.

    1992-01-01

    The Nuclear Regulatory Commission (NRC), with Brookhaven national Laboratory providing technical support, is continuing a preapplication review of the 471 MWt, advanced liquid metal reactor (ALMR), PRISM by General Electric. The revised design has been evaluated using the SSC code, for a series of loss of flow events (LOF) with and without gas expansion modules (GEMs). These devices have a net worth of 69 cents and have reduced the seriousness of the LOF in PRISM. However, it was found that the extremely low probability case of an instantaneous loss of 4 EM pumps without scram could lead to sodium boiling even with the GEMs

  7. The HBsAg Prevalence Among Blood Donors From Eastern Mediterranean and Middle Eastern Countries: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Babanejad, Mehran; Izadi, Neda; Najafi, Farid; Alavian, Seyed Moayed

    2016-03-01

    The world health organization (WHO) recommends that all blood donations should be screened for evidence of infections, such as hepatitis B. The present study aimed to determine the prevalence of hepatitis B surface antigen (HBsAg) in blood donors at the eastern Mediterranean region office (EMRO) of the WHO and middle eastern countries. A meta-analysis was carried out based on the results of an electronic literature search of PubMed, Ovid, Scopus, and Google Scholar for articles published from January 1, 2000, to August 31, 2015. In accordance with a significant homogeneity test and a large value of I2, the random effects model was used to aggregate data from the studies and produce the pooled estimates using the "Metan" command. We included 66 eligible studies. The pooled prevalence of HBsAg in blood donors of both EMRO and middle eastern (E and M) countries was 2.03% (95% confidence interval [CI]: 1.79 - 2.26). In addition, the prevalence rates in the EMRO countries was 1.99% (95% CI: 1.84 - 2.14) and 1.62% in the Middle Eastern countries (95% CI: 1.36 - 1.88). The prevalence among blood donors with more than one study was 1.58% in Egypt, 0.58% in Iran, 0.67% in Iraq, 2.84% in Pakistan, 3.02% in Saudi Arabia, 1.68% in Turkey, and 5.05% in Yemen. Based on the WHO classification of hepatitis B virus (HBV) prevalence, the prevalence of HBsAg in blood donors from E and M countries reached an intermediate level. However, there were low prevalence levels in some E and M countries.

  8. 75 FR 340 - Approval for Expansion of Subzone 22F, Abbott Molecular, Inc. (Pharmaceutical and Molecular...

    Science.gov (United States)

    2010-01-05

    ... DEPARTMENT OF COMMERCE Foreign-Trade Zones Board [Order No. 1654] Approval for Expansion of Subzone 22F, Abbott Molecular, Inc. (Pharmaceutical and Molecular Diagnostic Products), Chicago, IL, Area Pursuant to its authority under the Foreign-Trade Zones Act of June 18, 1934, as amended (19 U.S.C. 81a-81u...

  9. Effect of prism adaptation on left dichotic listening deficit in neglect patients: glasses to hear better?

    Science.gov (United States)

    Jacquin-Courtois, S; Rode, G; Pavani, F; O'Shea, J; Giard, M H; Boisson, D; Rossetti, Y

    2010-03-01

    Unilateral neglect is a disabling syndrome frequently observed following right hemisphere brain damage. Symptoms range from visuo-motor impairments through to deficient visuo-spatial imagery, but impairment can also affect the auditory modality. A short period of adaptation to a rightward prismatic shift of the visual field is known to improve a wide range of hemispatial neglect symptoms, including visuo-manual tasks, mental imagery, postural imbalance, visuo-verbal measures and number bisection. The aim of the present study was to assess whether the beneficial effects of prism adaptation may generalize to auditory manifestations of neglect. Auditory extinction, whose clinical manifestations are independent of the sensory modalities engaged in visuo-manual adaptation, was examined in neglect patients before and after prism adaptation. Two separate groups of neglect patients (all of whom exhibited left auditory extinction) underwent prism adaptation: one group (n = 6) received a classical prism treatment ('Prism' group), the other group (n = 6) was submitted to the same procedure, but wore neutral glasses creating no optical shift (placebo 'Control' group). Auditory extinction was assessed by means of a dichotic listening task performed three times: prior to prism exposure (pre-test), upon prism removal (0 h post-test) and 2 h later (2 h post-test). The total number of correct responses, the lateralization index (detection asymmetry between the two ears) and the number of left-right fusion errors were analysed. Our results demonstrate that prism adaptation can improve left auditory extinction, thus revealing transfer of benefit to a sensory modality that is orthogonal to the visual, proprioceptive and motor modalities directly implicated in the visuo-motor adaptive process. The observed benefit was specific to the detection asymmetry between the two ears and did not affect the total number of responses. This indicates a specific effect of prism adaptation on

  10. Evaluating lubricating capacity of vegetal oils using Abbott-Firestone curve

    Science.gov (United States)

    Georgescu, C.; Cristea, G. C.; Dima, C.; Deleanu, L.

    2017-02-01

    The paper presents the change of functional parameters defined on the Abbott-Firestone curve in order to evaluate the surface quality of the balls from the four ball tester, after tests done with several vegetable oils. The tests were done using two grades of rapeseed oil (degummed and refined) and two grades of soybean oil (coarse and degummed) and a common transmission oil (T90). Test parameters were 200 N and 0.576 m/s (1500 rpm) for 60 minutes. For the refined rapeseed oil, the changes in shape of the Abbott-Firestone curves are more dramatic, these being characterized by high values of Spk (the average value for the wear scars on the three balls), thus being 40% of the sum Svk + Sk + Spk, percentage also obtained for the soybean oil, but the value Spk being lower. For the degummed soybean oil, the profile height of the wear scars are taller than those obtained after testing the coarse soybean oil, meaning that the degumming process has a negative influence on the worn surface quality and the lubricating capacity of this oil. Comparing the surface quality of the wear scars on fixed tested balls is a reliable method to point out the lubricant properties of the vegetable oils, especially if they are compared to a “classical” lubricant as a non-additivated transmission mineral oil T90. The best surface after testing was obtained for the soybean oil, followed by T90 oil and the degummed grades of the soybean oil and rapeseed oil (these three giving very close values for the functional parameters), but the refined rapeseed oil generated the poorest quality of the wear scars on the balls, under the same testing conditions.

  11. Affective three-dimensional brain-computer interface created using a prism array-based display

    Science.gov (United States)

    Mun, Sungchul; Park, Min-Chul

    2014-12-01

    To avoid the vergence-accommodation mismatch and provide a strong sense of presence to users, we applied a prism array-based display when presenting three-dimensional (3-D) objects. Emotional pictures were used as visual stimuli to increase the signal-to-noise ratios of steady-state visually evoked potentials (SSVEPs) because involuntarily motivated selective attention by affective mechanisms can enhance SSVEP amplitudes, thus producing increased interaction efficiency. Ten male and nine female participants voluntarily participated in our experiments. Participants were asked to control objects under three viewing conditions: two-dimension (2-D), stereoscopic 3-D, and prism. The participants performed each condition in a counter-balanced order. One-way repeated measures analysis of variance showed significant increases in the positive predictive values in the prism condition compared to the 2-D and 3-D conditions. Participants' subjective ratings of realness and engagement were also significantly greater in the prism condition than in the 2-D and 3-D conditions, while the ratings for visual fatigue were significantly reduced in the prism condition than in the 3-D condition. The proposed methods are expected to enhance the sense of reality in 3-D space without causing critical visual fatigue. In addition, people who are especially susceptible to stereoscopic 3-D may be able to use the affective brain-computer interface.

  12. Optimisation of secretion of recombinant HBsAg virus-like particles: Impact on the development of HIV-1/HBV bivalent vaccines

    NARCIS (Netherlands)

    Michel, Marie; Lone, Yu-Chun; Centlivre, Mireille; Roux, Pascal; Wain-Hobson, Simon; Sala, Monica

    2007-01-01

    The hepatitis B surface antigen (HBsAg) assembles into virus-like particles (VLPs) that can be used as carrier of immunogenic peptides for the development of bivalent vaccine candidates. It is shown here that by respecting certain qualitative features of mammalian preS1 and preS2 protein domains

  13. Numerical and experimental evaluation of masonry prisms by finite element method

    Directory of Open Access Journals (Sweden)

    C. F.R. SANTOS

    Full Text Available Abstract This work developed experimental tests and numerical models able to represent the mechanical behavior of prisms made of ordinary and high strength concrete blocks. Experimental tests of prisms were performed and a detailed micro-modeling strategy was adopted for numerical analysis. In this modeling technique, each material (block and mortar was represented by its own mechanical properties. The validation of numerical models was based on experimental results. It was found that the obtained numerical values of compressive strength and modulus of elasticity differ by 5% from the experimentally observed values. Moreover, mechanisms responsible for the rupture of the prisms were evaluated and compared to the behaviors observed in the tests and those described in the literature. Through experimental results it is possible to conclude that the numerical models have been able to represent both the mechanical properties and the mechanisms responsible for failure.

  14. Differing results of direct and indirect solid phase radioimmunoassay for HBsAg in acute hepatitis

    International Nuclear Information System (INIS)

    Strohm, W.D.; Legler, K.; Gerlich, W.; Stamm, B.; Zimmer, S.; Biotest-Serum-Institut G.m.b.H., Frankfurt am Main; Goettingen Univ.

    1978-01-01

    In 54 patients suffering from active viral hepatitis the indirect solid phase radioimmunoassay (ind-SPRIA) for HBsAg was positive in 9 cases the direct solid phase radioimmunoassay (d-SPRIA) being negative. In 2 further cases ind-SPRIA was positive during several weeks but d-SPRIA only once. AntiHBc could be detected in 9 of these patients. In 7 patients the usual decrease of the transaminase activity was followed by a second elavation with prolongation of the disease. The unknown factor detected by ind-SPRIA suggests a special of acute hepatitis. (orig.) [de

  15. Differing results of direct and indirect solid phase radioimmunoassay for HBsAg in acute hepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Strohm, W D; Legler, K; Gerlich, W; Stamm, B; Zimmer, S [Frankfurt Univ. (Germany, F.R.). Abt. fuer Gastroenterologie; Biotest-Serum-Institut G.m.b.H., Frankfurt am Main (Germany, F.R.); Goettingen Univ. (Germany, F.R.). Hygiene-Institut)

    1978-09-01

    In 54 patients suffering from active viral hepatitis the indirect solid phase radioimmunoassay (ind-SPRIA) for HBsAg was positive in 9 cases the direct solid phase radioimmunoassay (d-SPRIA) being negative. In 2 further cases ind-SPRIA was positive during several weeks but d-SPRIA only once. AntiHBc could be detected in 9 of these patients. In 7 patients the usual decrease of the transaminase activity was followed by a second elavation with prolongation of the disease. The unknown factor detected by ind-SPRIA suggests a special of acute hepatitis.

  16. Suffering Quantified? Feasibility and Psychometric Characteristics of 2 Revised Versions of the Pictorial Representation of Illness and Self Measure (PRISM)

    NARCIS (Netherlands)

    PhD Ad J.J.M. Vingerhoets; PhD Marjet G.B.G. Blokhorst; MSc Jolene L.M. Reimus; MSc Annemieke M.A. van Nunen; MD E.J.M. Wouters

    2008-01-01

    The Pictorial Representation of Illness and Self Measure (PRISM) assesses suffering. In this article, the authors explored the feasibility and psychometric qualities of 2 revised versions of the PRISM-PRISM-R1 and PRISM-R2-that they used in 3 studies of participants with different medical problems.

  17. Prion-like nanofibrils of small molecules (PriSM): A new frontier at the intersection of supramolecular chemistry and cell biology.

    Science.gov (United States)

    Zhou, Jie; Du, Xuewen; Xu, Bing

    2015-01-01

    Formed by non-covalent interactions and not defined at genetic level, the assemblies of small molecules in biology are complicated and less explored. A common morphology of the supramolecular assemblies of small molecules is nanofibrils, which coincidentally resembles the nanofibrils formed by proteins such as prions. So these supramolecular assemblies are termed as prion-like nanofibrils of small molecules (PriSM). Emerging evidence from several unrelated fields over the past decade implies the significance of PriSM in biology and medicine. This perspective aims to highlight some recent advances of the research on PriSM. This paper starts with description of the intriguing similarities between PriSM and prions, discusses the paradoxical features of PriSM, introduces the methods for elucidating the biological functions of PriSM, illustrates several examples of beneficial aspects of PriSM, and finishes with the promises and current challenges in the research of PriSM. We anticipate that the research of PriSM will contribute to the fundamental understanding at the intersection of supramolecular chemistry and cell biology and ultimately lead to a new paradigm of molecular (or supramolecular) therapeutics for biomedicine.

  18. Radioimmunologic determination of hepatitis B antigen (HBsAG) in selected groups of persons and in special blood preparations

    Energy Technology Data Exchange (ETDEWEB)

    Lipsic, T; Geso, L [Clinic of Haematology and Blood Transfusion, Bratislava (Czechoslovakia)

    1978-06-30

    Presence of HBsAg was investigated by the RIA method in groups: exposed patients, blood donors, medical staff and different plasma preparations, namely: antihaemophilic cryoprotein (AHCp), Fibrinogen, I. Cohn's fraction and PPSB. 1789 samples of serum or converted material (plasma and its fractions) were investigated. In 405 cases AUSRIA-I method was used, the remaining 1384 cases were investigated by AUSRIA-II. Data are tabulated.

  19. Establishment and correction of an Echelle cross-prism spectrogram reduction model

    Science.gov (United States)

    Zhang, Rui; Bayanheshig; Li, Xiaotian; Cui, Jicheng

    2017-11-01

    The accuracy of an echelle cross-prism spectrometer depends on the matching degree between the spectrum reduction model and the actual state of the spectrometer. However, the error of adjustment can change the actual state of the spectrometer and result in a reduction model that does not match. This produces an inaccurate wavelength calibration. Therefore, the calibration of a spectrogram reduction model is important for the analysis of any echelle cross-prism spectrometer. In this study, the spectrogram reduction model of an echelle cross-prism spectrometer was established. The image position laws of a spectrometer that varies with the system parameters were simulated to the influence of the changes in prism refractive index, focal length and so on, on the calculation results. The model was divided into different wavebands. The iterative method, least squares principle and element lamps with known characteristic wavelength were used to calibrate the spectral model in different wavebands to obtain the actual values of the system parameters. After correction, the deviation of actual x- and y-coordinates and the coordinates calculated by the model are less than one pixel. The model corrected by this method thus reflects the system parameters in the current spectrometer state and can assist in accurate wavelength extraction. The instrument installation and adjustment would be guided in model-repeated correction, reducing difficulty of equipment, respectively.

  20. Hepatitis B surface antigen (HBsAg) and core antigen (HBcAg) combine CpG oligodeoxynucletides as a novel therapeutic vaccine for chronic hepatitis B infection.

    Science.gov (United States)

    Li, Jianqiang; Ge, Jun; Ren, Sulin; Zhou, Tong; Sun, Ying; Sun, Honglin; Gu, Yue; Huang, Hongying; Xu, Zhenxing; Chen, Xiaoxiao; Xu, Xiaowei; Zhuang, Xiaoqian; Song, Cuiling; Jia, Fangmiao; Xu, Aiguo; Yin, Xiaojin; Du, Sean X

    2015-08-20

    Hepatitis B virus infection is a non-cytopathic hepatotropic virus which can lead to chronic liver disease and hepatocellular carcinoma. Traditional therapies fail to provide sustained control of viral replication and liver damage in most patients. As an alternative strategy, immunotherapeutic approaches have shown promising efficacy in the treatment of chronic hepatitis B patients. Here, we investigated the efficacy of a novel therapeutic vaccine formulation consisting of two HBV antigens, HBsAg and HBcAg, and CpG adjuvant. This vaccine formulation elicits forceful humoral responses directed against HBsAg/HBcAg, and promotes a Th1/Th2 balance response against HBsAg and a Th1-biased response against HBcAg in both C57BL/6 and HBV transgenic mice. Vigorous cellular immune response was also detected in HBV transgenic mice, for a significantly higher number of HBs/HBc-specific IFN-γ secreting CD4+ and CD8+ T cells was generated. Moreover, vaccinated mice elicited significantly intense in vivo CTL attack, reduced serum HBsAg level without causing liver damage in HBV transgenic mice. In summary, this study demonstrates a novel therapeutic vaccine with the potential to elicit vigorous humoral and cellular response, overcoming tolerance in HBV transgenic mice. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Prioritization Risk Integration Simulation Model (PRISM) For Environmental Remediation and Waste Management - 12097

    Energy Technology Data Exchange (ETDEWEB)

    Pentz, David L.; Stoll, Ralph H.; Greeves, John T. [Predicus LLC, Issaquah, WA 98027 (United States); Miller, R. Ian [GoldSim Technology Group, LLC, Issaquah, WA 98027 (United States); Nutt, W. Mark [Argonne National Laboratory, Argonne, IL 60439 (United States)

    2012-07-01

    The PRISM (Prioritization Risk Integration Simulation Model), a computer model was developed to support the Department of Energy's Office of Environmental Management (DOE-EM) in its mission to clean up the environmental legacy from the Nation's nuclear weapons materials production complex. PRISM provides a comprehensive, fully integrated planning tool that can tie together DOE-EM's projects. It is designed to help DOE managers develop sound, risk-informed business practices and defend program decisions. It provides a better ability to understand and manage programmatic risks. The underlying concept for PRISM is that DOE-EM 'owns' a portfolio of environmental legacy obligations (ELOs), and that its mission is to transform the ELOs from their current conditions to acceptable conditions, in the most effective way possible. There are many types of ELOs - - contaminated soils and groundwater plumes, disused facilities awaiting D and D, and various types of wastes waiting for processing or disposal. For a given suite of planned activities, PRISM simulates the outcomes as they play out over time, allowing for all key identified uncertainties and risk factors. Each contaminated building, land area and waste stream is tracked from cradle to grave, and all of the linkages affecting different waste streams are captured. The progression of the activities is fully dynamic, reflecting DOE-EM's prioritization approaches, precedence requirements, available funding, and the consequences of risks and uncertainties. The top level of PRISM is the end-user interface that allows rapid evaluation of alternative scenarios and viewing the results in a variety of useful ways. PRISM is a fully probabilistic model, allowing the user to specify uncertainties in input data (such as the magnitude of an existing groundwater plume, or the total cost to complete a planned activity) as well as specific risk events that might occur. PRISM is based on the GoldSim software

  2. Prism therapy and visual rehabilitation in homonymous visual field loss.

    LENUS (Irish Health Repository)

    O'Neill, Evelyn C

    2012-02-01

    PURPOSE: Homonymous visual field defects (HVFD) are common and frequently occur after cerebrovascular accidents. They significantly impair visual function and cause disability particularly with regard to visual exploration. The purpose of this study was to assess a novel interventional treatment of monocular prism therapy on visual functioning in patients with HVFD of varied etiology using vision targeted, health-related quality of life (QOL) questionnaires. Our secondary aim was to confirm monocular and binocular visual field expansion pre- and posttreatment. METHODS: Twelve patients with acquired, documented HVFD were eligible to be included. All patients underwent specific vision-targeted, health-related QOL questionnaire and monocular and binocular Goldmann perimetry before commencing prism therapy. Patients were fitted with monocular prisms on the side of the HVFD with the base-in the direction of the field defect creating a peripheral optical exotropia and field expansion. After the treatment period, QOL questionnaires and perimetry were repeated. RESULTS: Twelve patients were included in the treatment group, 10 of whom were included in data analysis. Overall, there was significant improvement within multiple vision-related, QOL functioning parameters, specifically within the domains of general health (p < 0.01), general vision (p < 0.05), distance vision (p < 0.01), peripheral vision (p < 0.05), role difficulties (p < 0.05), dependency (p < 0.05), and social functioning (p < 0.05). Visual field expansion was shown when measured monocularly and binocularly during the study period in comparison with pretreatment baselines. CONCLUSIONS: Patients with HVFD demonstrate decreased QOL. Monocular sector prisms can improve the QOL and expand the visual field in these patients.

  3. Analysis of postulated events for the revised ALMR/PRISM design

    International Nuclear Information System (INIS)

    Slovik, G.C.; Van Tuyle, G.J.

    1991-01-01

    The PRISM reactor is presently under pre-application licensing review by the NRC, with Brookhaven National Laboratory (BNL) providing technical assistance. In this paper, the authors describe the latest set of results from their SSC and MINET code calculations. Series of postulated events were analyzed, for the most current PRISM design, to evaluate the system performance under unscrammed conditions. The PRISM reactor utilizes a metal fuel composed of 27% Pu, 10% Zr, and 63% U, based on the fuel developed by Argonne National Laboratory as part of the Integral Fast Reactor program. The fuel has a small power and temperature defect as a result of the high fuel thermal conductivity of metal and a hard neutron spectrum. The reactivity feedbacks of the core are designed to provide a negative response to off-normal, high temperature conditions, by invoking negative responses from the thermal expansion of the fuel, control rods, and core radial dimensions. The core restraint system incorporates the limited free bowing feature, which generates an outward bow of the in-core portion of the fuel assembly when a temperature gradient exits. The core also has three Gas Expansion Modules (GEMs) placed around the periphery, which will remove a combined worth of -69 cents of reactivity when the pumps are tripped from full power conditions. In evaluating this passive shutdown response, in which the PRISM reactor power should decrease significantly in response to overheated conditions, one considers three classes of unscrammed events. These include the unscrammed loss of flow (ULOF), loss of heat sink (ULOHS), and transient over power (UTOP) events

  4. PRISM: Processing routines in IDL for spectroscopic measurements (installation manual and user's guide, version 1.0)

    Science.gov (United States)

    Kokaly, Raymond F.

    2011-01-01

    This report describes procedures for installing and using the U.S. Geological Survey Processing Routines in IDL for Spectroscopic Measurements (PRISM) software. PRISM provides a framework to conduct spectroscopic analysis of measurements made using laboratory, field, airborne, and space-based spectrometers. Using PRISM functions, the user can compare the spectra of materials of unknown composition with reference spectra of known materials. This spectroscopic analysis allows the composition of the material to be identified and characterized. Among its other functions, PRISM contains routines for the storage of spectra in database files, import/export of ENVI spectral libraries, importation of field spectra, correction of spectra to absolute reflectance, arithmetic operations on spectra, interactive continuum removal and comparison of spectral features, correction of imaging spectrometer data to ground-calibrated reflectance, and identification and mapping of materials using spectral feature-based analysis of reflectance data. This report provides step-by-step instructions for installing the PRISM software and running its functions.

  5. Automated quantification of Epstein-Barr Virus in whole blood of hematopoietic stem cell transplant patients using the Abbott m2000 system.

    Science.gov (United States)

    Salmona, Maud; Fourati, Slim; Feghoul, Linda; Scieux, Catherine; Thiriez, Aline; Simon, François; Resche-Rigon, Matthieu; LeGoff, Jérôme

    2016-08-01

    Accurate quantification of Epstein-Barr virus (EBV) load in blood is essential for the management of post-transplant lymphoproliferative disorders. The automation of DNA extraction and amplification may improve accuracy and reproducibility. We evaluated the EBV PCR Kit V1 with fully automated DNA extraction and amplification on the m2000 system (Abbott assay). Conversion factor between copies and international units (IU), lower limit of quantification, imprecision and linearity were determined in a whole blood (WB) matrix. Results from 339 clinical WB specimens were compared with a home-brew real-time PCR assay used in our laboratory (in-house assay). The conversion factor between copies and IU was 3.22 copies/IU. The lower limit of quantification (LLQ) was 1000 copies/mL. Intra- and inter-assay coefficients of variation were 3.1% and 7.9% respectively for samples with EBV load higher than the LLQ. The comparison between Abbott assay and in-house assay showed a good concordance (kappa = 0.77). Loads were higher with the Abbott assay (mean difference = 0.62 log10 copies/mL). The EBV PCR Kit V1 assay on the m2000 system provides a reliable and easy-to-use method for quantification of EBV DNA in WB. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Entsymaattisen Abbott Architect c8000 HbA1c -menetelmän validointi

    OpenAIRE

    Karjalainen, Laura

    2013-01-01

    Opinnäytetyö suoritettiin THL:n Tautiriskiyksikön analyyttisen biokemian laboratoriossa (TLAB). Työssä validoitiin uusi entsymaattinen Abbott Architect c8000 HbA1c -menetelmä, jota käytetään diabetekseen liittyvissä tutkimuksissa. Validoinnilla haluttiin varmistaa uuden mittaustekniikaltaan erilaisen menetelmän toimivuus. Menetelmävertailussa komparatiivisena menetelmänä oli laboratoriossa rutiinikäytössä ollut Abbottin immunoturbidimetrinen HbA1c-menetelmä. Uusi entsymaattinen menetelmä peru...

  7. Characterizing structures on borehole images and logging data of the Nankai trough accretionary prism: new insights

    Science.gov (United States)

    Jurado, Maria Jose

    2016-04-01

    IODP has extensively used the D/V Chikyu to drill the Kumano portion of the Nankai Trough, including two well sites within the Kumano Basin. IODP Expeditions 338 and 348 drilled deep into the inner accretionary prism south of the Kii Peninsula collecting a suite of LWD data, including natural gamma ray, electrical resistivity logs and borehole images, suitable to characterize structures (fractures and faults) inside the accretionary prism. Structural interpretation and analysis of logging-while-drilling data in the deep inner prism revealed intense deformation of a generally homogenous lithology characterized by bedding that dips steeply (60-90°) to the NW, intersected by faults and fractures. Multiple phases of deformation are characterized. IODP Expedition borehole images and LWD data acquired in the last decade in previous and results of NantroSEIZE IODP Expeditions (314, 319) were also analyzed to investigate the internal geometries and structures of the Nankai Trough accretionary prism. This study focused mainly on the characterization of the different types of structures and their specific position within the accretionary prism structures. New structural constraints and methodologies as well as a new approach to the characterization of study of active structures inside the prism will be presented.

  8. Lack of immune potentiation by complexing HBsAg in a heat-inactivated hepatitis B vaccine with antibody in hepatitis B immunoglobulin

    NARCIS (Netherlands)

    Lelie, P. N.; van Amelsfoort, P. J.; Martine de Groot, C. S.; Bakker, E.; Schaasberg, W.; Niessen, J. C.; Reesink, H. W.

    1989-01-01

    In a randomized, dose-response study among 305 health care workers, we examined whether the immunogenicity of a heat-inactivated hepatitis B vaccine could be enhanced when HBsAg was complexed by anti-HBs contained in hepatitis B immunoglobulin either at equivalent proportions or at 10-fold antigen

  9. Prism foil from an LCD monitor as a tool for teaching introductory optics

    International Nuclear Information System (INIS)

    Planinsic, Gorazd; Gojkosek, Mihael

    2011-01-01

    Transparent prism foil is part of a backlight system in LCD monitors that are widely used today. This paper describes the optical properties of the prism foil and several pedagogical applications suitable for undergraduate introductory physics level. Examples include experiments that employ refraction, total internal reflection, diffraction and image formation in a nontrivial way and are therefore particularly useful for active learning strategies.

  10. Prism foil from an LCD monitor as a tool for teaching introductory optics

    Energy Technology Data Exchange (ETDEWEB)

    Planinsic, Gorazd; Gojkosek, Mihael, E-mail: gorazd.planinsic@fmf.uni-lj.si [Faculty of Mathematics and Physics, University of Ljubljana, Jadranska 19 (Slovenia)

    2011-03-15

    Transparent prism foil is part of a backlight system in LCD monitors that are widely used today. This paper describes the optical properties of the prism foil and several pedagogical applications suitable for undergraduate introductory physics level. Examples include experiments that employ refraction, total internal reflection, diffraction and image formation in a nontrivial way and are therefore particularly useful for active learning strategies.

  11. Evaluation of the Performance of Routine Information System Management (PRISM framework: evidence from Uganda

    Directory of Open Access Journals (Sweden)

    Aqil Anwer

    2010-07-01

    Full Text Available Abstract Background Sound policy, resource allocation and day-to-day management decisions in the health sector require timely information from routine health information systems (RHIS. In most low- and middle-income countries, the RHIS is viewed as being inadequate in providing quality data and continuous information that can be used to help improve health system performance. In addition, there is limited evidence on the effectiveness of RHIS strengthening interventions in improving data quality and use. The purpose of this study is to evaluate the usefulness of the newly developed Performance of Routine Information System Management (PRISM framework, which consists of a conceptual framework and associated data collection and analysis tools to assess, design, strengthen and evaluate RHIS. The specific objectives of the study are: a to assess the reliability and validity of the PRISM instruments and b to assess the validity of the PRISM conceptual framework. Methods Facility- and worker-level data were collected from 110 health care facilities in twelve districts in Uganda in 2004 and 2007 using records reviews, structured interviews and self-administered questionnaires. The analysis procedures include Cronbach's alpha to assess internal consistency of selected instruments, test-retest analysis to assess the reliability and sensitivity of the instruments, and bivariate and multivariate statistical techniques to assess validity of the PRISM instruments and conceptual framework. Results Cronbach's alpha analysis suggests high reliability (0.7 or greater for the indices measuring a promotion of a culture of information, RHIS tasks self-efficacy and motivation. The study results also suggest that a promotion of a culture of information influences RHIS tasks self-efficacy, RHIS tasks competence and motivation, and that self-efficacy and the presence of RHIS staff have a direct influence on the use of RHIS information, a key aspect of RHIS performance

  12. Pictorial Representation of Illness and Self Measure (PRISM): A novel visual instrument to measure quality of life in dermatological inpatients.

    Science.gov (United States)

    Mühleisen, Beda; Büchi, Stefan; Schmidhauser, Simone; Jenewein, Josef; French, Lars E; Hofbauer, Günther F L

    2009-07-01

    To validate the PRISM (Pictorial Representation of Illness and Self Measure) tool, a novel visual instrument, for the assessment of health-related quality of life in dermatological inpatients compared with the Dermatology Life Quality Index (DLQI) and the Skindex-29 questionnaires and to report qualitative information on PRISM. In an open longitudinal study, PRISM and Skindex-29 and DLQI questionnaires were completed and HRQOL measurements compared. Academic dermatological inpatient ward. The study population comprised 227 sequential dermatological inpatients on admission. Patients completed the PRISM tool and the Skindex-29 and DLQI questionnaires at admission and discharge. PRISM Self-Illness Separation (SIS) score; Skindex-29 and DLQI scores; and qualitative PRISM information by Mayring inductive qualitative context analysis. The PRISM scores correlated well with those from the Skindex-29 (rho = 0.426; P quality of life questionnaires to assess changes in the burden of suffering during hospitalization. Inductive qualitative context analysis revealed impairment of adjustment and self-image as major aspects. Patients overall expected symptomatic and functional improvement. In patients with psoriasis and leg ulcers, many expected no treatment benefit. The PRISM tool proved to be convenient and reliable for health-related quality of life assessment, applicable for a wide range of skin diseases, and correlated with DLQI and Skindex-29 scores. With the PRISM tool, free-text answers allow for the assessment of individual information and potentially customized therapeutic approaches.

  13. A compact and lightweight off-axis lightguide prism in near to eye display

    Science.gov (United States)

    Zhuang, Zhenfeng; Cheng, Qijia; Surman, Phil; Zheng, Yuanjin; Sun, Xiao Wei

    2017-06-01

    We propose a method to improve the design of an off-axis lightguide configuration for near to eye displays (NED) using freeform optics technology. The advantage of this modified optical system, which includes an organic light-emitting diode (OLED), a doublet lens, an imaging lightguide prism and a compensation prism, is that it increases optical length path, offers a smaller size, as well as avoids the obstructed views, and matches the user's head shape. In this system, the light emitted from the OLED passes through the doublet lens and is refracted/reflected by the imaging lightguide prism, which is used to magnify the image from the microdisplay, while the compensation prism is utilized to correct the light ray shift so that a low-distortion image can be observed in a real-world setting. A NED with a 4 mm diameter exit pupil, 21.5° diagonal full field of view (FoV), 23 mm eye relief, and a size of 33 mm by 9.3 mm by 16 mm is designed. The developed system is compact, lightweight and suitable for entertainment and education application.

  14. BRSCW Reference Set Application: Karen Abbott -University of Arkansas (2014) — EDRN Public Portal

    Science.gov (United States)

    Our earlier glycoproteomic studies have identified bisecting glycoslyation and core fucosylation changes on particular glycoproteins in endometrioid ovarian cancer tissues and plasma (Abbott et al, 2010, Proteomics). We have validated that these glycan changes occur on the same glycoproteins in serous ovarian cancer plasma using a lectin-pull down western blot assays. We would like to used pooled reference samples to develop a sensitive magnetic bead-based assay to detect these glycoproteins with bisecting and core fucosylation changes.

  15. Hyperbolic prisms and foams in Hele-Shaw cells

    Energy Technology Data Exchange (ETDEWEB)

    Tufaile, A., E-mail: tufaile@usp.br [Soft Matter Laboratory, Escola de Artes, Ciencias e Humanidades, Universidade de Sao Paulo, 03828-000, Sao Paulo (Brazil); Tufaile, A.P.B. [Soft Matter Laboratory, Escola de Artes, Ciencias e Humanidades, Universidade de Sao Paulo, 03828-000, Sao Paulo (Brazil)

    2011-10-03

    The propagation of light in foams creates patterns which are generated due to the reflection and refraction of light. One of these patterns is observed by the formation of multiple mirror images inside liquid bridges in a layer of bubbles in a Hele-Shaw cell. We are presenting the existence of these patterns in foams and their relation with hyperbolic geometry and Sierpinski gaskets using the Poincare disk model. The images obtained from the experiment in foams are compared to the case of hyperbolic optical elements. -- Highlights: → The chaotic scattering of light in foams generating deltoid patterns is based on hyperbolic geometry. → The deltoid patterns are obtained through the Plateau borders in a Hele-Shaw cell. → The Plateau borders act like hyperbolic prism. → Some effects of the refraction and reflection of the light rays were studied using a hyperbolic prism.

  16. Instantaneous flow field above the free end of finite-height cylinders and prisms

    International Nuclear Information System (INIS)

    Rostamy, N.; Sumner, D.; Bergstrom, D.J.; Bugg, J.D.

    2013-01-01

    Highlights: • PIV measurements of the flow above the free end of finite-height bodies. • Effect of cross-sectional shape of the models on the instantaneous flow. • Small-scale structures generated by the separated shear layer were revealed. • Effect of aspect ratio on the reattachment of the separated flow on the free end. -- Abstract: The flow above the free ends of surface-mounted finite-height circular cylinders and square prisms was studied experimentally using particle image velocimetry (PIV). Cylinders and prisms with aspect ratios of AR = 9, 7, 5, and 3 were tested at a Reynolds number of Re = 4.2 × 10 4 . The bodies were mounted normal to a ground plane and were partially immersed in a turbulent zero-pressure-gradient boundary layer, where the boundary layer thickness relative to the body width was δ/D = 1.6. PIV measurements were made above the free ends of the bodies in a vertical plane aligned with the flow centreline. The present PIV results provide insight into the effects of aspect ratio and body shape on the instantaneous flow field. The recirculation zone under the separated shear layer is larger for the square prism of AR = 3 compared to the more slender prism of AR = 9. Also, for a square prism with low aspect ratio (AR = 3), the influence of the reverse flow over the free end surface becomes more significant compared to that for a higher aspect ratio (AR = 9). For the circular cylinder, a cross-stream vortex forms within the recirculation zone. As the aspect ratio of the cylinder decreases, the reattachment point of the separated flow on the free end surface moves closer to the trailing edge. For both the square prism and circular cylinder cases, the instantaneous velocity vector field and associated in-plane vorticity field revealed small-scale structures mostly generated by the separated shear layer

  17. Strategic Planning for Chronic Disease Prevention in Rural America: Looking Through a PRISM Lens.

    Science.gov (United States)

    Honeycutt, Amanda A; Wile, Kristina; Dove, Cassandra; Hawkins, Jackie; Orenstein, Diane

    2015-01-01

    Community-level strategic planning for chronic disease prevention. To share the outcomes of the strategic planning process used by Mississippi Delta stakeholders to prevent and reduce the negative impacts of chronic disease in their communities. A key component of strategic planning was participants' use of the Prevention Impacts Simulation Model (PRISM) to project the reduction, compared with the status quo, in deaths and costs from implementing interventions in Mississippi Delta communities. Participants in Mississippi Delta strategic planning meetings used PRISM, a user-friendly, evidence-based simulation tool that includes 22 categories of policy, systems, and environmental change interventions, to pose what-if questions that explore the likely short- and long-term effects of an intervention or any desired combination of the 22 categories of chronic disease intervention programs and policies captured in PRISM. These categories address smoking, air pollution, poor nutrition, and lack of physical activity. Strategic planning participants used PRISM outputs to inform their decisions and actions to implement interventions. Rural communities in the Mississippi Delta. A diverse group of 29 to 34 local chronic disease prevention stakeholders, known as the Mississippi Delta Strategic Alliance. Community plans and actions that were developed and implemented as a result of local strategic planning. Existing strategic planning efforts were complemented by the use of PRISM. The Mississippi Delta Strategic Alliance decided to implement new interventions to improve air quality and transportation and to expand existing interventions to reduce tobacco use and increase access to healthy foods. They also collaborated with the Department of Transportation to raise awareness and use of the current transportation network. The Mississippi Delta Strategic Alliance strategic planning process was complemented by the use of PRISM as a tool for strategic planning, which led to the

  18. Determinazione quantitativa di HCV-RNA: valutazione comparativa dei saggi Abbott Real-Time e Versant bDNA v.3

    Directory of Open Access Journals (Sweden)

    Aldo Manzin

    2007-06-01

    Full Text Available Hepatitis C virus (HCV RNA measurement before, during and after antiviral therapy has become an essential tool in the management of interferon-based treatment of HCV-related infections. Conventional Polymerase Chain Reaction (PCR has been largely used to obtain quantitative data, but laborious, time-consuming post-PCR handling steps are required to gain valuable results. Real time (RT PCR now provides advantages over end-point (EP PCR due to its improved rapidity, sensitivity, reproducibility and the reduced risk of carry-over contamination, and has now proven itself to be valuable for the more precise monitoring of viral load kinetics and assessing antiviral response.The Abbott Real-Time HCV-RNA is a recently introduced assay for the automated processing of clinical samples and HCV-RNA quantitation: its basic technology relies on use of fluorescent linear probes (dynamic range using 0.5 ml as input target= 12-108 IU/mL and a hybridization/detection step at low temperature (35°C, which allows target mismatches to be tolerated. To determine the clinical application of the Abbott Real-Time assay and defining its correlation with the Bayer Versant bDNA v.3 assay, 68 consecutive samples from unselected HCV-infected patients were retrospectively analysed with RT and the results obtained using the two tests compared.A good correlation was found between RT-PCR and bDNA: 97% of samples tested had a result within a 0.5 log HCV IU/mL difference (bias=0.15 log, whereas 6 samples negative with bDNA gave positive results with Abbott RT (range, 1.89-3.07 log IU/mL and “in-house” qualitative RT-PCR assays.

  19. Propagation of rotational Risley-prism-array-based Gaussian beams in turbulent atmosphere

    Science.gov (United States)

    Chen, Feng; Ma, Haotong; Dong, Li; Ren, Ge; Qi, Bo; Tan, Yufeng

    2018-03-01

    Limited by the size and weight of prism and optical assembling, Rotational Risley-prism-array system is a simple but effective way to realize high power and superior beam quality of deflecting laser output. In this paper, the propagation of the rotational Risley-prism-array-based Gaussian beam array in atmospheric turbulence is studied in detail. An analytical expression for the average intensity distribution at the receiving plane is derived based on nonparaxial ray tracing method and extended Huygens-Fresnel principle. Power in the diffraction-limited bucket is chosen to evaluate beam quality. The effect of deviation angle, propagation distance and intensity of turbulence on beam quality is studied in detail by quantitative simulation. It reveals that with the propagation distance increasing, the intensity distribution gradually evolves from multiple-petal-like shape into the pattern that contains one main-lobe in the center with multiple side-lobes in weak turbulence. The beam quality of rotational Risley-prism-array-based Gaussian beam array with lower deviation angle is better than its counterpart with higher deviation angle when propagating in weak and medium turbulent (i.e. Cn2 beam quality of higher deviation angle arrays degrades faster as the intensity of turbulence gets stronger. In the case of propagating in strong turbulence, the long propagation distance (i.e. z > 10km ) and deviation angle have no influence on beam quality.

  20. Development and application of GIS-based PRISM integration through a plugin approach

    Science.gov (United States)

    Lee, Woo-Seop; Chun, Jong Ahn; Kang, Kwangmin

    2014-05-01

    A PRISM (Parameter-elevation Regressions on Independent Slopes Model) QGIS-plugin was developed on Quantum GIS platform in this study. This Quantum GIS plugin system provides user-friendly graphic user interfaces (GUIs) so that users can obtain gridded meteorological data of high resolutions (1 km × 1 km). Also, this software is designed to run on a personal computer so that it does not require an internet access or a sophisticated computer system. This module is a user-friendly system that a user can generate PRISM data with ease. The proposed PRISM QGIS-plugin is a hybrid statistical-geographic model system that uses coarse resolution datasets (APHRODITE datasets in this study) with digital elevation data to generate the fine-resolution gridded precipitation. To validate the performance of the software, Prek Thnot River Basin in Kandal, Cambodia is selected for application. Overall statistical analysis shows promising outputs generated by the proposed plugin. Error measures such as RMSE (Root Mean Square Error) and MAPE (Mean Absolute Percentage Error) were used to evaluate the performance of the developed PRISM QGIS-plugin. Evaluation results using RMSE and MAPE were 2.76 mm and 4.2%, respectively. This study suggested that the plugin can be used to generate high resolution precipitation datasets for hydrological and climatological studies at a watershed where observed weather datasets are limited.

  1. Novel laterally pumped by prism laser configuration for compact solid-state lasers

    International Nuclear Information System (INIS)

    Dascalu, T; Salamu, G; Sandu, O; Voicu, F; Pavel, N

    2013-01-01

    We propose a new laser configuration in which the pump radiation is coupled into the laser crystal through a prism. The laser medium is square shaped and the prism is attached on one of its lateral sides, near one of the crystal extremities. The diode-laser fiber end is placed close to the prism hypotenuse, the pump radiation is coupled into the laser crystal through the opposite surface of the prism and propagates into the crystal through total internal reflections. This laser geometry is simple to align and permits the realization of compact diode-pumped laser systems, as well as power scaling. A diode-pumped Nd:YAG laser yielding pulses of 2.1 mJ energy under a pump with pulses of 9.9 mJ is demonstrated. The laser slope efficiency is 0.22. Furthermore, this geometry enables one to obtain passively Q-switched lasers with the saturable absorber crystal placed between the resonator high-reflectivity mirror and the laser crystal. A Nd:YAG laser, passively Q-switched by a Cr 4+ :YAG crystal with initial transmission T 0 = 0.90, delivering laser output with a pulsed energy of 93 μJ, a duration of 26 ns and a pump threshold of 1.9 mJ, is realized in order to prove the concept. (letter)

  2. Laser Oscillator Incorporating a Wedged Polarization Rotator and a Porro Prism as Cavity Mirror

    Science.gov (United States)

    Li, Steven

    2011-01-01

    A laser cavity was designed and implemented by using a wedged polarization rotator and a Porro prism in order to reduce the parts count, and to improve the laser reliability. In this invention, a z-cut quartz polarization rotator is used to compensate the wavelength retardance introduced by the Porro prism. The polarization rotator rotates the polarization of the linear polarized beam with a designed angle that is independent of the orientation of the rotator. This unique property was used to combine the retardance compensation and a Risley prism to a single optical component: a wedged polarization rotator. This greatly simplifies the laser alignment procedure and reduces the number of the laser optical components.

  3. Design of partially optically stable reflector systems and prisms

    Science.gov (United States)

    Tsai, Chuang-Yu

    2010-09-01

    The characteristics and design method of the total optically stable (TOS) reflector systems/prisms were introduced in an early paper (Tsai and Lin in Appl. Opt. 47:4158-4163, 2008), where only two types of TOS reflector system exist, namely preservation or retroreflection. In this paper, we introduce the partially optically stable (POS) reflector system, which is only optically stable about a specific directional vector; nevertheless, the exiting light ray is not restricted to preservation or retroreflection. The proposed paper also presents an analytic method for the design of POS reflector systems comprised of multiple reflectors. Furthermore, it is shown that a POS prism can be obtained by adding two refracting flat boundary surfaces with specific conditions at the entrance and exit positions of the light ray in an optical system with multiple reflectors.

  4. PRISM [Power Reactor Inherently Safe Module] design concept enhances waste management

    International Nuclear Information System (INIS)

    Thompson, M.L.; Berglund, R.C.

    1989-01-01

    PRISM, a modular advanced liquid metal reactor (ALMR), has been designed conceptually by GE under the US Department of Energy sponsorship. The concept design and analyses have been primarily focused on passive safety and improved construction and operating costs. Significantly, the unique design of multiple modules and features of PRISM enhance waste management over conventional reactor systems. This paper provides an overview of PRISM of these enhancements. Inherent to the ALMR's, the sodium coolant precludes crud buildup on reactor surfaces and in components and waste for disposal. Preliminary evaluations indicate this fundamental feature results in factors of 2-4 less waste volume and 2-3 orders of magnitude less curies per megawatt-electric for ultimate disposal. For example, the tap designed for sodium cleanup is expected to be exchanged only once every thirty years. Also, inherent to ALMR's, burning waste actinides and selected fission products to preclude their accumulation and burial is very attractive. The hard neutron spectrum of ALMR burns the actinides efficiently and is not poisoned by the actinides and fission products. The modular design of PRISM components (and the fuel cycle equipment) permit replacement without expensive and potentially hazardous volume reduction. For example, the functional components of the reference electromagnetic pump and IHK can be removed intact for waste disposal. Although development of the reference metal fuel is not completed, it is estimated that (low-level) waste from recycle of the fuel will result in significantly less volume than would be generated by aqueous recycle of oxide fuel. 6 refs., 10 figs

  5. Eu{sup 3+}-doped Y{sub 2}O{sub 3} hexagonal prisms: Shape-controlled synthesis and tailored luminescence properties

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Errui [Key Laboratory of Design and Assembly of Functional Nanostructures, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Fuzhou, Fujian 350002 (China); Li, Guangshe [Fujian Provincial Key Laboratory of Nanomaterials, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Fuzhou, Fujian 350002 (China); Fu, Chaochao; Zheng, Jing [Key Laboratory of Design and Assembly of Functional Nanostructures, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Fuzhou, Fujian 350002 (China); Huang, Xinsong [Fujian Provincial Key Laboratory of Nanomaterials, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Fuzhou, Fujian 350002 (China); Xu, Wen [State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012 (China); Li, Liping, E-mail: lipingli@fjirsm.ac.cn [Key Laboratory of Design and Assembly of Functional Nanostructures, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Fuzhou, Fujian 350002 (China)

    2015-10-25

    In this work, Eu{sup 3+} doped Y{sub 2}O{sub 3} hexagonal prisms were synthesized by a novel two-phase approach, which involves water at the bottom as aqueous phase and oleylamine in the above as oil phase. With this unique reaction system, precursors of hexagonal prisms Y{sub 4}O(OH){sub 9}(NO{sub 3}) were first obtained by simply varying the volume ratio of water to oleylamine. Time-dependent experiments were systematically performed to reveal the growth mechanism of the precursor. After subsequent heat treatment, these precursors transformed to Y{sub 2}O{sub 3} hexagonal prisms with controlled diameters and aspect ratios varying from 4 to 19. Such a transformation is preceded via a topotactic process, as indicated by TG-DTA and mass spectra. Eventually, all Eu{sup 3+} doped Y{sub 2}O{sub 3} hexagonal prisms were found to exhibit an intensive red emission at 611 nm, which corresponds to {sup 5}D{sub 0}→{sup 7}F{sub 2} transition of Eu{sup 3+}. With varying the aspect ratio of hexagonal prisms and increasing Eu{sup 3+} concentration in Y{sub 2}O{sub 3}, an optimum external quantum efficiency was achieved. - Graphical abstract: In this work, Eu{sup 3+} doped Y{sub 2}O{sub 3} hexagonal prisms with controlled aspect ratio from 4.4 to 19.3 were synthesized by transformation of the precursor Y{sub 4}O(OH){sub 9}(NO{sub 3}) hexagonal prisms from a novel two-phase reaction system. The growth mechanism of the precursor has been systematically investigated, and a topotactic phase transformation from precursors to cubic Y{sub 2}O{sub 3} is for the first time put forward. By the size controlling and aspect ratio adjusting, the luminescence emission intensity as well as external quantum efficiency of Eu{sup 3+} doped Y{sub 2}O{sub 3} hexagonal prisms is further tailored to show an optimum. - Highlights: • Eu{sup 3+} doped Y{sub 2}O{sub 3} hexagonal prisms were synthesized by a novel two-phase approach. • Inheriting mechanism of prisms morphology from Y{sub 4}O(OH){sub 9

  6. Processing and review interface for strong motion data (PRISM) software, version 1.0.0—Methodology and automated processing

    Science.gov (United States)

    Jones, Jeanne; Kalkan, Erol; Stephens, Christopher

    2017-02-23

    A continually increasing number of high-quality digital strong-motion records from stations of the National Strong-Motion Project (NSMP) of the U.S. Geological Survey (USGS), as well as data from regional seismic networks within the United States, call for automated processing of strong-motion records with human review limited to selected significant or flagged records. The NSMP has developed the Processing and Review Interface for Strong Motion data (PRISM) software to meet this need. In combination with the Advanced National Seismic System Quake Monitoring System (AQMS), PRISM automates the processing of strong-motion records. When used without AQMS, PRISM provides batch-processing capabilities. The PRISM version 1.0.0 is platform independent (coded in Java), open source, and does not depend on any closed-source or proprietary software. The software consists of two major components: a record processing engine and a review tool that has a graphical user interface (GUI) to manually review, edit, and process records. To facilitate use by non-NSMP earthquake engineers and scientists, PRISM (both its processing engine and review tool) is easy to install and run as a stand-alone system on common operating systems such as Linux, OS X, and Windows. PRISM was designed to be flexible and extensible in order to accommodate new processing techniques. This report provides a thorough description and examples of the record processing features supported by PRISM. All the computing features of PRISM have been thoroughly tested.

  7. Performance evaluation of LUMIPULSE G1200 autoimmunoanalyzer for the detection of serum hepatitis B virus markers.

    Science.gov (United States)

    Choi, Seung Jun; Park, Yongjung; Lee, Eun Young; Kim, Sinyoung; Kim, Hyon-Suk

    2013-05-01

    We evaluated recently introduced automated immunoassay analyzer LUMIPULSE G1200 (Fujirebio, Inc., Tokyo, Japan) for detecting serologic hepatitis B virus (HBV) markers by comparison with the results by ARCHITECT i4000SR (Abbott, Abbott Park, IL). Precision performance was evaluated over 20 days. HBV surface antigen (HBsAg), HBV e antigen (HBeAg), antibodies to HBV core antigen (anti-HBc), antibodies to HBeAg (anti-HBe), and antibodies to HBsAg (anti-HBs) in a total of 1,000 serum samples were assessed by the two analyzers. Discrepant results were retested by COBAS e411 (Roche Diagnostics, Mannheim, Germany). LUMIPULSE showed excellent precision performance of total imprecision less than 3.5% coefficient of variation. The qualitative results between the two analyzers were agreed with each other in 92.0-99.8% of the specimens according to the different HBV markers. The degrees of reactions for HBeAg were moderately correlated between the two analyzers (r = 0.60), and those of other HBV markers were well correlated (r = 0.80 or greater). However, there were 183 discrepancies among 1,000 cases, and most of them showed degree of reaction around the cutoff values. LUMIPULSE G1200 showed well-concordant results with ARCITHECT for hepatitis B serologic tests. However, results near the cutoff values would need to be retested with other immunoassay or molecular methods, when the serological profiles of HBV markers are unusual or are not correlated to the clinical conditions of the patient, due to discrepancies between the immunoassay analyzers. © 2013 Wiley Periodicals, Inc.

  8. Watching Nanoscale Self-Assembly Kinetics of Gold Prisms in Liquids

    Science.gov (United States)

    Kim, Juyeong; Ou, Zihao; Jones, Matthew R.; Chen, Qian

    We use liquid-phase transmission electron microscopy to watch self-assembly of gold triangular prisms into polymer-like structures. The in situ dynamics monitoring enabled by liquid-phase transmission electron microscopy, single nanoparticle tracking, and the marked conceptual similarity between molecular reactions and nanoparticle self-assembly combined elucidate the following mechanistic understanding: a step-growth polymerization based assembly statistics, kinetic pathways sampling particle curvature dependent energy minima and their interconversions, and directed assembly into polymorphs (linear or cyclic chains) through in situ modulation of the prism bonding geometry. Our study bridges the constituent kinetics on the molecular and nanoparticle length scales, which enriches the design rules in directed self-assembly of anisotropic nanoparticles.

  9. SU-G-IeP1-13: Sub-Nyquist Dynamic MRI Via Prior Rank, Intensity and Sparsity Model (PRISM)

    International Nuclear Information System (INIS)

    Jiang, B; Gao, H

    2016-01-01

    Purpose: Accelerated dynamic MRI is important for MRI guided radiotherapy. Inspired by compressive sensing (CS), sub-Nyquist dynamic MRI has been an active research area, i.e., sparse sampling in k-t space for accelerated dynamic MRI. This work is to investigate sub-Nyquist dynamic MRI via a previously developed CS model, namely Prior Rank, Intensity and Sparsity Model (PRISM). Methods: The proposed method utilizes PRISM with rank minimization and incoherent sampling patterns for sub-Nyquist reconstruction. In PRISM, the low-rank background image, which is automatically calculated by rank minimization, is excluded from the L1 minimization step of the CS reconstruction to further sparsify the residual image, thus allowing for higher acceleration rates. Furthermore, the sampling pattern in k-t space is made more incoherent by sampling a different set of k-space points at different temporal frames. Results: Reconstruction results from L1-sparsity method and PRISM method with 30% undersampled data and 15% undersampled data are compared to demonstrate the power of PRISM for dynamic MRI. Conclusion: A sub- Nyquist MRI reconstruction method based on PRISM is developed with improved image quality from the L1-sparsity method.

  10. Human immunodeficiency virus (HIV) seropositivity and hepatitis B surface antigenemia (HBSAG) among blood donors in Benin city, Edo state, Nigeria.

    Science.gov (United States)

    Umolu, Patience Idia; Okoror, Lawrence Ehis; Orhue, Philip

    2005-03-01

    Human Immunodeficiency Virus and Hepatitis B virus are blood borne pathogens that can be transmitted through blood transfusion and could pose a huge problem in areas where mechanisms of ensuring blood safety are suspect. This study became necessary in a population where most of the blood for transfusion is from commercial blood donors. A total of 130 donors comprising 120 commercial donors and 10 voluntary donors were tested for antibodies to human immunodeficiency virus and hepatitis B surface antigen in Benin city using Immunocomb HIV - 1 and 2 Biospot kit and Quimica Clinica Aplicada direct latex agglutination method respectively. Thirteen (10%) samples were HIV seropositive and 7(5.8%) were HBsAg positive. The age bracket 18 - 25years had the highest numbers of donors and also had the highest number of HBsAg positive cases (7.8%) while the age group 29 - 38years had highest number of HIV seropositive cases. High prevalence of HIV antibodies and Hepatitis B surface antigen was found among commercial blood donors. Appropriate and compulsory screening of blood donors using sensitive methods, must be ensured to prevent post transfusion hepatitis and HIV.

  11. Prism adaptation improves postural imbalance in neglect patients

    NARCIS (Netherlands)

    Nijboer, Tanja C W; Olthoff, Liselot; Van der Stigchel, Stefan; Visser-Meily, Johanna M a

    2014-01-01

    Several studies have found a negative relation between neglect and postural imbalance. The aim of the current study was to investigate the influence of a single session of prism adaptation on balance [i.e. mediolateral and anteroposterior center of pressure (CoP)] and postural sway (i.e. mean

  12. Behaviour of concrete beams reinforced withFRP prestressed concrete prisms

    Science.gov (United States)

    Svecova, Dagmar

    The use of fibre reinforced plastics (FRP) to reinforce concrete is gaining acceptance. However, due to the relatively low modulus of FRP, in comparison to steel, such structures may, if sufficient amount of reinforcement is not used, suffer from large deformations and wide cracks. FRP is generally more suited for prestressing. Since it is not feasible to prestress all concrete structures to eliminate the large deflections of FRP reinforced concrete flexural members, researchers are focusing on other strategies. A simple method for avoiding excessive deflections is to provide sufficiently high amount of FRP reinforcement to limit its stress (strain) to acceptable levels under service loads. This approach will not be able to take advantage of the high strength of FRP and will be generally uneconomical. The current investigation focuses on the feasibility of an alternative strategy. This thesis deals with the flexural and shear behaviour of concrete beams reinforced with FRP prestressed concrete prisms. FRP prestressed concrete prisms (PCP) are new reinforcing bars, made by pretensioning FRP and embedding it in high strength grout/concrete. The purpose of the research is to investigate the feasibility of using such pretensioned rebars, and their effect on the flexural and shear behaviour of reinforced concrete beams over the entire loading range. Due to the prestress in the prisms, deflection of concrete beams reinforced with this product is substantially reduced, and is comparable to similarly steel reinforced beams. The thesis comprises both theoretical and experimental investigations. In the experimental part, nine beams reinforced with FRP prestressed concrete prisms, and two companion beams, one steel and one FRP reinforced were tested. All the beams were designed to carry the same ultimate moment. Excellent flexural and shear behaviour of beams reinforced with higher prestressed prisms is reported. When comparing deflections of three beams designed to have the

  13. HDV Seroprevalence in HBsAg Positive Patients

    International Nuclear Information System (INIS)

    Abbasi, A.; Bhutto, A. R.; Mahmood, K.; Butt, N.

    2014-01-01

    Objective: To find out the frequency of HDV seroprevalence and the demographic characteristics or HBsAg-HDV positive patients. Study Design: Cross-sectional analytical study. Place and Duration of Study: Jinnah Postgraduate Medical Centre and Civil Hospital, Medical Unit-III, Karachi, from March 2007 to April 2011. Methodology: Patients with positive HBsAg were included in the study. Those having co-infection with HCV or HIV, autoimmune hepatitis, alcoholic hepatitis, Wilson's disease and haemochromatosis were excluded. After detailed history and physical examination all the patients underwent laboratory workup including complete blood count, liver function test, viral profile (HAV, HCV, HIV and anti-HDV) and prothrombin time. While in selected patients, HBc (core) antibodies, ultrasound abdomen, serum iron profile, ANA and liver biopsy were also carried out whenever needed to establish a clinical stage of liver disease. Results: There were 374 patients with 266 (71.1%) males and 108 (28.9%) females with overall mean age of 31.64 +- 8.66 years. Overall frequency of anti-HDV antibodies positivity was found in 28.1% (n = 105) patients. HDV seropositivity was slightly more prevalent in males as compared to females (28.57% vs. 26.57%). HDV seropositivity frequency was significantly higher in patients who presented with acute hepatitis/hepatic failure as compared to other clinical diagnoses (p = 0.027) and in those sub-sets of patients who had raised ALT levels (p = 0.012). Conclusion: There was a high frequency of HDV seropositivity in the studied population particularly in males with acute hepatitis or hepatic failure, having raised ALT levels. The emphasis should be on preventive measures taken by other countries to reduce the prevalence of these treatment challenging infections. (author)

  14. Transient safety performance of the PRISM innovative liquid metal reactor

    International Nuclear Information System (INIS)

    Magee, P.M.; Dubberley, A.E.; Rhow, S.K.; Wu, T.

    1988-01-01

    The PRISM sodium-cooled reactor concept utilizes passive safety characteristics and modularity to increase performance margins, improve licensability, reduce owner's risk and reduce costs. The relatively small size of each reactor module (471 MWt) facilitates the use of passive self-shutdown and shutdown heat removal features, which permit design simplification and reduction of safety-related systems. Key to the transient performance is the inherent negative reactivity feedback characteristics of the core design resulting from the use of metal (U-Pu-Zr) swing, and very low control rod runout worth. Selected beyond design basis events relying only on these core design features are analyzed and the design margins summarized to demonstrate the advancement in reactor safety achieved with the PRISM design concept

  15. High-performance beam steering using electrowetting-driven liquid prism fabricated by a simple dip-coating method

    Energy Technology Data Exchange (ETDEWEB)

    Enrico Clement, Carlos; Park, Sung-Yong, E-mail: mpeps@nus.edu.sg [Department of Mechanical Engineering, National University of Singapore, Block EA, #07-08, 9 Engineering Drive 1, 117576 (Singapore)

    2016-05-09

    A high degree of beam steering is demonstrated using an electrowetting-driven liquid prism. While prism devices have typically relied on complex and expensive laboratory setups, such as high-vacuum facilities for fabrication of dielectric layers, this work utilizes a simple dip-coating method to provide an ion gel layer as a dielectric, offering 2 or 3 orders higher specific capacitance (c ≈ 10 μF/cm{sup 2}) than that of conventional dielectrics. Analytical studies present the effects of liquid selection and arrangement on overall prism performance. For experimental demonstrations of high-performance beam steering, we not only selected two immiscible liquids of water and 1-bromonaphthalene (1-BN) oil which provide the large refractive index difference (n{sub water} = 1.33 and n{sub 1-BN} = 1.65 at λ = 532 nm) between them, but also utilized a double-stacked prism configuration which increases the number of interfaces for incoming light to be steered. At a prism apex angle of φ = 27°, we were able to achieve significantly large beam steering of up to β = 19.06°, which is the highest beam steering performance ever demonstrated using electrowetting technology.

  16. HIV-1 viral load measurement in venous blood and fingerprick blood using Abbott RealTime HIV-1 DBS assay.

    Science.gov (United States)

    Tang, Ning; Pahalawatta, Vihanga; Frank, Andrea; Bagley, Zowie; Viana, Raquel; Lampinen, John; Leckie, Gregor; Huang, Shihai; Abravaya, Klara; Wallis, Carole L

    2017-07-01

    HIV RNA suppression is a key indicator for monitoring success of antiretroviral therapy. From a logistical perspective, viral load (VL) testing using Dried Blood Spots (DBS) is a promising alternative to plasma based VL testing in resource-limited settings. To evaluate the analytical and clinical performance of the Abbott RealTime HIV-1 assay using a fully automated one-spot DBS sample protocol. Limit of detection (LOD), linearity, lower limit of quantitation (LLQ), upper limit of quantitation (ULQ), and precision were determined using serial dilutions of HIV-1 Virology Quality Assurance stock (VQA Rush University), or HIV-1-containing armored RNA, made in venous blood. To evaluate correlation, bias, and agreement, 497 HIV-1 positive adult clinical samples were collected from Ivory Coast, Uganda and South Africa. For each HIV-1 participant, DBS-fingerprick, DBS-venous and plasma sample results were compared. Correlation and bias values were obtained. The sensitivity and specificity were analyzed at a threshold of 1000 HIV-1 copies/mL generated using the standard plasma protocol. The Abbott HIV-1 DBS protocol had an LOD of 839 copies/mL, a linear range from 500 to 1×10 7 copies/mL, an LLQ of 839 copies/mL, a ULQ of 1×10 7 copies/mL, and an inter-assay SD of ≤0.30 log copies/mL for all tested levels within this range. With clinical samples, the correlation coefficient (r value) was 0.896 between DBS-fingerprick and plasma and 0.901 between DBS-venous and plasma, and the bias was -0.07 log copies/mL between DBS-fingerprick and plasma and -0.02 log copies/mL between DBS-venous and plasma. The sensitivity of DBS-fingerprick and DBS-venous was 93%, while the specificity of both DBS methods was 95%. The results demonstrated that the Abbott RealTime HIV-1 assay with DBS sample protocol is highly sensitive, specific and precise across a wide dynamic range and correlates well with plasma values. The Abbott RealTime HIV-1 assay with DBS sample protocol provides an

  17. An assessment of the Crossed Porro Prism Resonator

    Science.gov (United States)

    See, B. A.; Fueloep, K.; Seymour, R.

    1980-08-01

    Lasers with crossed porro prism resonators for military laser rangefinder and designator applications are studied. Properties of these devices are reviewed and advantages over normal mirror resonators are examined. The theory of operating is treated and the mechanical stability and other features of the laser are examined and compared to standard mirror resonators.

  18. A novel and compact spectral imaging system based on two curved prisms

    Science.gov (United States)

    Nie, Yunfeng; Bin, Xiangli; Zhou, Jinsong; Li, Yang

    2013-09-01

    As a novel detection approach which simultaneously acquires two-dimensional visual picture and one-dimensional spectral information, spectral imaging offers promising applications on biomedical imaging, conservation and identification of artworks, surveillance of food safety, and so forth. A novel moderate-resolution spectral imaging system consisting of merely two optical elements is illustrated in this paper. It can realize the function of a relay imaging system as well as a 10nm spectral resolution spectroscopy. Compared to conventional prismatic imaging spectrometers, this design is compact and concise with only two special curved prisms by utilizing two reflective surfaces. In contrast to spectral imagers based on diffractive grating, the usage of compound-prism possesses characteristics of higher energy utilization and wider free spectral range. The seidel aberration theory and dispersive principle of this special prism are analyzed at first. According to the results, the optical system of this design is simulated, and the performance evaluation including spot diagram, MTF and distortion, is presented. In the end, considering the difficulty and particularity of manufacture and alignment, an available method for fabrication and measurement is proposed.

  19. Optofluidic laser scanner based on a rotating liquid prism.

    Science.gov (United States)

    Kopp, Daniel; Lehmann, Lukas; Zappe, Hans

    2016-03-20

    We demonstrate an electrowetting-actuated optofluidic system based on a rotatable liquid prism implemented as a two-dimensional laser scanner. The system is fabricated through a novel technology using a patterned flexible polymeric foil on which a high density of electrodes is structured and which is subsequently inserted into a cylindrical housing. The resulting radial electrode array is used for electrowetting actuation of two fluids filled into the cylinder, which allows a controllable tilt and orientation of the planar liquid interface and thus represents a tunable rotating prism. Finite element simulations and subsequent experimental verification show that this highly planar and precisely positionable liquid/liquid interface may be actuated to a deflection angle of ±6.4°, with a standard deviation of ±0.18°, and rotated 360° about the vertical axis. Power consumption is limited to several microwatts, and switching times of several hundred milliseconds were determined.

  20. Multisensory and Modality-Specific Influences on Adaptation to Optical Prisms

    Directory of Open Access Journals (Sweden)

    Elena Calzolari

    2017-11-01

    Full Text Available Visuo-motor adaptation to optical prisms displacing the visual scene (prism adaptation, PA is a method used for investigating visuo-motor plasticity in healthy individuals and, in clinical settings, for the rehabilitation of unilateral spatial neglect. In the standard paradigm, the adaptation phase involves repeated pointings to visual targets, while wearing optical prisms displacing the visual scene laterally. Here we explored differences in PA, and its aftereffects (AEs, as related to the sensory modality of the target. Visual, auditory, and multisensory – audio-visual – targets in the adaptation phase were used, while participants wore prisms displacing the visual field rightward by 10°. Proprioceptive, visual, visual-proprioceptive, auditory-proprioceptive straight-ahead shifts were measured. Pointing to auditory and to audio-visual targets in the adaptation phase produces proprioceptive, visual-proprioceptive, and auditory-proprioceptive AEs, as the typical visual targets did. This finding reveals that cross-modal plasticity effects involve both the auditory and the visual modality, and their interactions (Experiment 1. Even a shortened PA phase, requiring only 24 pointings to visual and audio-visual targets (Experiment 2, is sufficient to bring about AEs, as compared to the standard 92-pointings procedure. Finally, pointings to auditory targets cause AEs, although PA with a reduced number of pointings (24 to auditory targets brings about smaller AEs, as compared to the 92-pointings procedure (Experiment 3. Together, results from the three experiments extend to the auditory modality the sensorimotor plasticity underlying the typical AEs produced by PA to visual targets. Importantly, PA to auditory targets appears characterized by less accurate pointings and error correction, suggesting that the auditory component of the PA process may be less central to the building up of the AEs, than the sensorimotor pointing activity per se. These

  1. Numerical simulation of blast wave propagation in vicinity of standalone prism on flat plate

    Science.gov (United States)

    Valger, Svetlana; Fedorova, Natalya; Fedorov, Alexander

    2018-03-01

    In the paper, numerical simulation of shock wave propagation in the vicinity of a standalone prism and a prism with a cavity in front of it was carried out. The modeling was based on the solution of 3D Euler equations and Fluent software was used as a main computational tool. The algorithm for local dynamic mesh adaptation to high gradients of pressure was applied. The initial stage of the explosion of condensed explosive was described with the help of "Compressed balloon method". The research allowed describing the characteristic stages of the blast in a semi-closed space, the structure of secondary shock waves and their interaction with obstacles. The numerical approach in Fluent based on combining inviscid gas dynamics methods and "Compressed balloon method" was compared with the method which had been used by the authors earlier with the help of AUTODYN and which is based on the use of the hydrodynamic model of a material to describe state of detonation products. For the problem of shock wave propagation in the vicinity of standalone prism the comparison of the simulation results obtained using both the methods with the experimental data was performed on the dependence of static pressure and effective momentum on time for the characteristic points located on prism walls.

  2. Characteristic analysis of a polarization output coupling Porro prism resonator

    Science.gov (United States)

    Yang, Hailong; Meng, Junqing; Chen, Weibiao

    2015-02-01

    An Electro-optical Q-switched Nd:YAG slab laser with a crossed misalignment Porro prism resonator for space applications has been theoretically and experimentally investigated. The phase shift induced by the combination of different wave plates and Porro prism azimuth angles have been studied for creating high loss condition prior to Q-switching. The relationship of the effective output coupling reflectivity and the employed Q-switch driving voltage is explored by using Jones matrix optics. In the experiment, the maximum output pulse energy of 93 mJ with 14-ns pulse duration is obtained at the repetition rate of 20 Hz and the optical-to-optical conversion efficiency is 16.8%. The beam quality factors are M 2 x = 2.5 and M 2y = 2.2, respectively.

  3. THz Photonic Band-Gap Prisms Fabricated by Fiber Drawing

    DEFF Research Database (Denmark)

    Busch, Stefan F.; Xu, Lipeng; Stecher, Matthias

    2012-01-01

    We suggest a novel form of polymeric based 3D photonic crystal prisms for THz frequencies which could be fabricated using a standard fiber drawing technique. The structures are modeled and designed using a finite element analyzing technique. Using this simulation software we theoretically study...

  4. Nystatin LF (Aronex/Abbott).

    Science.gov (United States)

    Arikan, S; Rex, J H

    2001-04-01

    November 1998, Aronex signed a licensing collaboration with Abbott Laboratories for the worldwide rights to nystatin LF [305531].

  5. Possibilities of magnet prism β-spectrometer application in on-line experiments

    International Nuclear Information System (INIS)

    Akhmetov, K.M.; Arynov, S.

    1996-01-01

    The main attention is paid to works with particle beam in up-to-date nuclear investigations. The application of magnet prism β-spectrometer for works in 'on-line' experiments is considered in this article. The source chamber and detector chamber are distanted from each other on great distance (4 m) and are out of operation field of spectrometer. There is a reliable defence of operating field of device from external parasitic fields by the magnetic screens system. The additional advantage is a factor that source (target) and detector could replacing in specific directions about few centimetres during the device operating. The main β-spectroscopic performances of device are compared with Grenoble spectroscopic complex. The liner depression of prism spectrometer account for from 3,6 up to 6 m; light force - from 2·10 -4 up to 6·10 -4 up to 4π; operating resolving power - 0,02-0,05% by impulse. Investigation range is from several keV up to 3 MeV. There are all opportunities for installing of the on-line magnetic prism spectrometer on the U-150 accelerator and the WWR-K reactor. Spectrometer application in 'on-line' experiments gives possibility to obtain more wide information. 4 refs

  6. The Behaviour of Palm Oil Fibre Block Masonry Prism under Eccentric Compressive Loading

    Science.gov (United States)

    Mokhtar, Mardiha; Kolop, Roslan; Baizura Hamid, Nor; Kaamin, Masiri; Farhan Rosdi, Mohd; Ngadiman, Norhayati; Sahat, Suhaila

    2017-08-01

    Dry-stacked masonry offers great benefits in constructing masonry buildings. Several examples from previous research show that dry masonry is reasonable alternative to the traditional building system. By addition of fibre, the ductility and the propagation of cracking will be improved. This study investigates the dry stack oil palm fibre block prisms which were subjected to eccentricity compression loads. These concrete blocks were cast using a single mould with suitable fibre-cement composition namely 1:4 (cement: sand) and 0.40 water to the cement ratio based on cement weight. Prisms test using 400 (length) × 150 (width) × 510 (height) mm specimen was carried under eccentric load. There were forty eight (48) prisms built with different configurations based on their volume of fibre. In this study, one types of grout were used namely the fine grout of mix 1:3:2 (cement: sand: aggregate (5mm maximum). Based on the test performed, the failure mechanism and influencing parameters were discussed. From compressive strength test result, it shows that the strength of concrete block decreased with the increase of fibre used. Although the control sample has the higher strength compared to concrete with EFB, it can be seen from mode failure of masonry prism that fibre could extend the cracking time. These results show that the oil palm fibre blocks can improve the failure behaviour and suitable to be used as load bearing wall construction in Malaysia.

  7. The personalized reminder information and social management system (PRISM) trial: rationale, methods and baseline characteristics.

    Science.gov (United States)

    Czaja, Sara J; Boot, Walter R; Charness, Neil; A Rogers, Wendy; Sharit, Joseph; Fisk, Arthur D; Lee, Chin Chin; Nair, Sankaran N

    2015-01-01

    Technology holds promise in terms of providing support to older adults. To date, there have been limited robust systematic efforts to evaluate the psychosocial benefits of technology for older people and identify factors that influence both the usability and uptake of technology systems. In response to these issues, we developed the Personal Reminder Information and Social Management System (PRISM), a software application designed for older adults to support social connectivity, memory, knowledge about topics, leisure activities and access to resources. This trail is evaluating the impact of access to the PRISM system on outcomes such as social isolation, social support and connectivity. This paper reports on the approach used to design the PRISM system, study design, methodology and baseline data for the trial. The trial is multi-site randomized field trial. PRISM is being compared to a Binder condition where participants received a binder that contained content similar to that found on PRISM. The sample includes 300 older adults, aged 65-98 years, who lived alone and at risk for being isolated. The primary outcome measures for the trial include indices of social isolation and support and well-being. Secondary outcomes measures include indices of computer proficiency, technology uptake and attitudes towards technology. Follow-up assessments occurred at 6 and 12 months post-randomization. The results of this study will yield important information about the potential value of technology for older adults. The study also demonstrates how a user-centered iterative design approach can be incorporated into the design and evaluation of an intervention protocol. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Abbott-Deser-Tekin Charge of Dilaton Black Holes with Squashed Horizons

    Institute of Scientific and Technical Information of China (English)

    Jun-Jin Peng; Wen-Chang Xiang; Shao-Hong Cai

    2016-01-01

    We consider the conserved charge of static black holes with squashed horizons in the Einstein-Maxwell-dilaton theory via both the Abbott-Deser-Tekin (ADT) method and its off-shell generalization.We first make use of the original ADT method to compute the mass of the dilaton squashed black holes in terms of three different reference spacetimes,which are the asymptotic geometry,the fiat background and the spacetime of the KaluzaKlein monopole with boundary matched to the original metric,respectively.Each mass satisfies the first law of black hole thermodynamics,although the mass computed on the basis of the boundary matching the KaluzaKlein monopole is different from that of the other two reference spacetimes.Then the mass of the black holes is evaluated through the off-shell generalized ADT method.

  9. Spherical Lenses and Prisms Lead to Postural Instability in Both Dyslexic and Non Dyslexic Adolescents

    Science.gov (United States)

    Kapoula, Zoi; Gaertner, Chrystal; Matheron, Eric

    2012-01-01

    There is controversy as to whether dyslexic children present systematic postural deficiency. Clinicians use a combination of ophthalmic prisms and proprioceptive soles to improve postural performances. This study examines the effects of convergent prisms and spherical lenses on posture. Fourteen dyslexics (13–17 years-old) and 11 non dyslexics (13–16 years-old) participated in the study. Quiet stance posturography was performed with the TechnoConcept device while subjects fixated a target at eye-level from a distance of 1_m. Four conditions were run: normal viewing; viewing the target with spherical lenses of −1 diopter (ACCOM1) over each eye; viewing with −3 diopters over each eye (ACCOM3); viewing with a convergent prism of 8 diopters per eye. Relative to normal viewing, the −1 lenses increased the surface of body sway significantly whereas the −3 diopter lenses only resulted in a significant increase of antero-posterior body sway. Thus, adolescents would appear to cope more effectively with stronger conflicts rather than subtle ones. The prism condition resulted in a significant increase in both the surface and the antero-posterior body sway. Importantly, all of these effects were similar for the two groups. Wavelet analysis (time frequency domain) revealed high spectral power of antero-posterior sway for the prism condition in both groups. In the ACCOM3 condition, the spectral power of antero-posterior sway decreased for non dyslexics but increased for dyslexics suggesting that dyslexics encounter more difficulty with accommodation. The cancelling time for medium range frequency (believed to be controlled by the cerebellum), was shorter in dyslexics, suggesting fewer instances of optimal control. We conclude that dyslexics achieve similar postural performances albeit less efficiently. Prisms and lenses destabilize posture for all teenagers. Thus, contrary to adults, adolescents do not seem to use efferent, proprioceptive ocular motor signals to

  10. Spherical lenses and prisms lead to postural instability in both dyslexic and non dyslexic adolescents.

    Directory of Open Access Journals (Sweden)

    Zoi Kapoula

    Full Text Available There is controversy as to whether dyslexic children present systematic postural deficiency. Clinicians use a combination of ophthalmic prisms and proprioceptive soles to improve postural performances. This study examines the effects of convergent prisms and spherical lenses on posture. Fourteen dyslexics (13-17 years-old and 11 non dyslexics (13-16 years-old participated in the study. Quiet stance posturography was performed with the TechnoConcept device while subjects fixated a target at eye-level from a distance of 1_m. Four conditions were run: normal viewing; viewing the target with spherical lenses of -1 diopter (ACCOM1 over each eye; viewing with -3 diopters over each eye (ACCOM3; viewing with a convergent prism of 8 diopters per eye. Relative to normal viewing, the -1 lenses increased the surface of body sway significantly whereas the -3 diopter lenses only resulted in a significant increase of antero-posterior body sway. Thus, adolescents would appear to cope more effectively with stronger conflicts rather than subtle ones. The prism condition resulted in a significant increase in both the surface and the antero-posterior body sway. Importantly, all of these effects were similar for the two groups. Wavelet analysis (time frequency domain revealed high spectral power of antero-posterior sway for the prism condition in both groups. In the ACCOM3 condition, the spectral power of antero-posterior sway decreased for non dyslexics but increased for dyslexics suggesting that dyslexics encounter more difficulty with accommodation. The cancelling time for medium range frequency (believed to be controlled by the cerebellum, was shorter in dyslexics, suggesting fewer instances of optimal control. We conclude that dyslexics achieve similar postural performances albeit less efficiently. Prisms and lenses destabilize posture for all teenagers. Thus, contrary to adults, adolescents do not seem to use efferent, proprioceptive ocular motor signals to

  11. Prism adaptation does not alter configural processing of faces [v1; ref status: indexed, http://f1000r.es/1wk

    Directory of Open Access Journals (Sweden)

    Janet H. Bultitude

    2013-10-01

    Full Text Available Patients with hemispatial neglect (‘neglect’ following a brain lesion show difficulty responding or orienting to objects and events on the left side of space. Substantial evidence supports the use of a sensorimotor training technique called prism adaptation as a treatment for neglect. Reaching for visual targets viewed through prismatic lenses that induce a rightward shift in the visual image results in a leftward recalibration of reaching movements that is accompanied by a reduction of symptoms in patients with neglect. The understanding of prism adaptation has also been advanced through studies of healthy participants, in whom adaptation to leftward prismatic shifts results in temporary neglect-like performance. Interestingly, prism adaptation can also alter aspects of non-lateralised spatial attention. We previously demonstrated that prism adaptation alters the extent to which neglect patients and healthy participants process local features versus global configurations of visual stimuli. Since deficits in non-lateralised spatial attention are thought to contribute to the severity of neglect symptoms, it is possible that the effect of prism adaptation on these deficits contributes to its efficacy. This study examines the pervasiveness of the effects of prism adaptation on perception by examining the effect of prism adaptation on configural face processing using a composite face task. The composite face task is a persuasive demonstration of the automatic global-level processing of faces: the top and bottom halves of two familiar faces form a seemingly new, unknown face when viewed together. Participants identified the top or bottom halves of composite faces before and after prism adaptation. Sensorimotor adaptation was confirmed by significant pointing aftereffect, however there was no significant change in the extent to which the irrelevant face half interfered with processing. The results support the proposal that the therapeutic effects

  12. PERANCANGAN DAN IMPLEMENTASI SISTEM PENGUKURAN KINERJA DENGAN METODE PERFORMANCE PRISM (Studi Kasus pada Hotel X)

    OpenAIRE

    Iwan Vanany; Dian Tanukhidah

    2004-01-01

    This article described a result of research design of performance measurement system in hotel business with Performance Prism Model. As long as, performance measurement system at hotel X not yet representatived organization performance according to comprehensif and integrated. Because of needed redesign performance measurement system with new model. From the objective condition of hotel X, Performance Prism model more representative than others. The result of design described that stakeholder...

  13. Use of the Tax Prism Method When Forming Tax Part of the Budget

    Directory of Open Access Journals (Sweden)

    Verovska Ludmila

    2017-06-01

    Full Text Available The tax prism method is developed for the assessment of tax part of the budget as well as for forecasting the influence of tax optimisation on it. There are certain trends in global practice. Developing and transition economies are characterised by low tax burden. Economically developed countries with a high level of social security of population are characterised by high tax burden. The analytical and graphic-analytical research for the purpose of determination of optimum size of the taxation using the tax prism has been conducted. In addition to the concept of ‘tax prism’, concepts such as static and dynamic tax prisms have been introduced, allowing to consider changes in the part of the budget of interest in connection with a possibility of taxation subjects to reduce the size of a tax burden by various methods of tax optimisation, and also to consider the influence of other factors on it. The use of this approach helps effectively to enhance the tax legislation by modelling high-quality and quantitative consequences of one or another changes and innovations.

  14. Preapplication safety evaluation report for the Power Reactor Innovative Small Module (PRISM) liquid-metal reactor

    International Nuclear Information System (INIS)

    Donoghue, J.E.; Donohew, J.N.; Golub, G.R.; Kenneally, R.M.; Moore, P.B.; Sands, S.P.; Throm, E.D.; Wetzel, B.A.

    1994-02-01

    This preapplication safety evaluation report (PSER) presents the results of the preapplication desip review for die Power Reactor Innovative Small Module (PRISM) liquid-mew (sodium)-cooled reactor, Nuclear Regulatory Commission (NRC) Project No. 674. The PRISM conceptual desip was submitted by the US Department of Energy in accordance with the NRC's ''Statement of Policy for the Regulation of Advanced Nuclear Power Plants'' (51 Federal Register 24643). This policy provides for the early Commission review and interaction with designers and licensees. The PRISM reactor desip is a small, modular, pool-type, liquid-mew (sodium)-cooled reactor. The standard plant design consists of dim identical power blocks with a total electrical output rating of 1395 MWe- Each power block comprises three reactor modules, each with a thermal rating of 471 MWt. Each module is located in its own below-grade silo and is co to its own intermediate heat transport system and steam generator system. The reactors utilize a metallic-type fuel, a ternary alloy of U-Pu-Zr. The design includes passive reactor shutdown and passive decay heat removal features. The PSER is the NRC's preliminary evaluation of the safety features in the PRISM design, including the projected research and development programs required to support the design and the proposed testing needs. Because the NRC review was based on a conceptual design, the PSER did not result in an approval of the design. Instead it identified certain key safety issues, provided some guidance on applicable licensing criteria, assessed the adequacy of the preapplicant's research and development programs, and concluded that no obvious impediments to licensing the PRISM design had been identified

  15. Neural mechanisms underlying spatial realignment during adaptation to optical wedge prisms.

    Science.gov (United States)

    Chapman, Heidi L; Eramudugolla, Ranmalee; Gavrilescu, Maria; Strudwick, Mark W; Loftus, Andrea; Cunnington, Ross; Mattingley, Jason B

    2010-07-01

    Visuomotor adaptation to a shift in visual input produced by prismatic lenses is an example of dynamic sensory-motor plasticity within the brain. Prism adaptation is readily induced in healthy individuals, and is thought to reflect the brain's ability to compensate for drifts in spatial calibration between different sensory systems. The neural correlate of this form of functional plasticity is largely unknown, although current models predict the involvement of parieto-cerebellar circuits. Recent studies that have employed event-related functional magnetic resonance imaging (fMRI) to identify brain regions associated with prism adaptation have discovered patterns of parietal and cerebellar modulation as participants corrected their visuomotor errors during the early part of adaptation. However, the role of these regions in the later stage of adaptation, when 'spatial realignment' or true adaptation is predicted to occur, remains unclear. Here, we used fMRI to quantify the distinctive patterns of parieto-cerebellar activity as visuomotor adaptation develops. We directly contrasted activation patterns during the initial error correction phase of visuomotor adaptation with that during the later spatial realignment phase, and found significant recruitment of the parieto-cerebellar network--with activations in the right inferior parietal lobe and the right posterior cerebellum. These findings provide the first evidence of both cerebellar and parietal involvement during the spatial realignment phase of prism adaptation. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  16. [Relationship between HBeAg from HBsAg positive mothers and regulatory T cells in neonates and its influence on HBV intrauterine transmission].

    Science.gov (United States)

    Hao, H Y; Yang, Z Q; Xu, X X; Wang, X F; Wang, B; Shi, X H; Fu, Z D; Wang, B; Wang, S P

    2017-10-10

    Objective: To explore the relationship between HBeAg in HBsAg positive mothers and CD(4)(+)CD(25)(+) Foxp3 (+)regulatory T cells (Treg) in newborns, as well as how they would influence the increasing risk on HBV intrauterine transmission. Methods: We collected information on general demographic characteristics and delivery on 270 HBsAg positive mothers and their newborns from the Third People's Hospital of Taiyuan. Fluorescence quantitative polymerase chain reaction (FQ-PCR) and chemiluminescence immunoassay (CLIA) were used to detect HBV DNA and HBV serological markers in peripheral blood from both mothers and neonates. The expression of Treg and other immune cells in peripheral blood of neonates were detected with flow cytometry (FCM). Results: Maternal HBeAg positive rates were associated with an increased risk of intrauterine transmission ( OR =4.08, 95 %CI : 1.89-8.82). Rates of Treg in newborns born to HBsAg-positive mothers were higher than that of the negative group ( Z =2.29, P =0.022). Each pair of the subjects was assigned to five different groups according to the HBeAg titers of mothers. Frequencies of both Treg and HBeAg in newborns and HBV DNA in mothers between the above said 5 groups showed similar trends of changing patterns and the differences between groups were statistically significant(χ(2)=18.73, P mother's HBeAg titers were positively related to the percentage of Treg in their newborns ( r(s) =0.19, P =0.039). In addition, the frequencies of Treg were negatively correlated with pDC and CD(4)(+) T cell in their newborns ( r(s) =-0.21, P =0.017; r(s) =-0.23, P =0.009). Conclusion: HBeAg from HBsAg positive mothers might have inhibited the function of neonatal DC cells and T cells to reduce the immune response to HBV by up-regulating the proportion of Treg and finally increased the risk of HBV intrauterine transmission.

  17. A new ASE filter: the 20-fold prism monochromator

    NARCIS (Netherlands)

    Bakker, L.P.; Freriks, J.M.; Kroesen, G.M.W.

    1999-01-01

    A new ASE filter is presented, consisting of 20 dispersion prisms and two spatial filters. The transmission of the filter is measured with a ring-dye laser. The 1 width of the filter is 0.23 nm. The transmission is approximately 80% for the transmitted wavelengths. The rejection is in the order of .

  18. Stress effects in prism coupling measurements of thin polymer films

    NARCIS (Netherlands)

    Agan, S.; Ay, F.; Kocabas, A.; Aydinli, A.

    Due to the increasingly important role of some polymers in optical waveguide technologies, precise measurement of their optical properties has become important. Typically, prism coupling to slab waveguides made of materials of interest is used to measure the relevant optical parameters. However,

  19. Importance of radioimmunoassays (HBsAg, HBsAb and HBcAb) for reducing the risk of hepatitis B transfer by blood

    International Nuclear Information System (INIS)

    Novak, J.; Kselikova, M.

    1979-01-01

    The principles are reported of the radioimmunoanalytical assay of the hepatitis B surface antigen, antibodies against this antigen which constitute immunologically indirect evidence, and antibodies against the nucleus of Dane's particles, which is circumstantial immunological evidence. The results obtained by radioimmunoassay are compared with those obtained by enzyme immunoassay. The results are presented obtained during the investigations of a total of 79 individuals, blood donors, health workers, and haemodialytic patients. In the whole group the hepatitis B surface antigen was proved by radioimmunoassay in 54%, by enzyme immunoassay in 47%; the antibody against the hepatitis B surface antigen in 19%; the antibody against the nucleus of the hepatitis B virus showed the largest proportion 75%. In 6.3% radioimmunoassay showed symptoms all three of hepatitis B, i.e., the surface antigen, the antibody against it, and the antibody against the hepatitis B virus nucleus; the correlation of the three symptoms is shown. The presence of HBsAg, HBsAb, and HBcAb is believed to be a contraindication of blood taking for routine purposes; the disappearance of HBsAg for a longer time may justify the re-inclusion among blood donors; the presence of HBsAb and HBcAb does not preclude the preparation of the plasma from such blood for the production of a specific anti-HBs immunoglobulin. (author)

  20. PERANCANGAN SISTEM PENGUKURAN KINERJA DENGAN METODE PERFORMANCE PRISM (STUDI KASUS PADA PDAM TIRTA MOEDAL CABANG SEMARANG TENGAH

    Directory of Open Access Journals (Sweden)

    Nia Budi Puspitasari

    2012-10-01

    Full Text Available Penelitian ini menguraikan hasil penelitian perancangan sistem pengukuran kinerja pada PDAM Tirta Moedal Semarang dengan model Performance Prism. Selama ini PDAM Tirta Moedal belum memiliki sistem pengukuran kinerja. Oleh karena itu, perlu dilakukan perancangan sistem pengukuran kinerja. Dari kondisi PDAM Tirta Moedal Semarang, model yang tepat digunakan adalah model performance prism  dibanding model lain. Sistem pengukuran kinerja ini memiliki 44 KPI yang meliputi 12 KPI pelanggan, 9 KPI karyawan, 11 KPI pemilik modal, 6 KPI supplier, 6 KPI pemerintah dan masyarakat di sekitar lingkungan. Dari hasil implementasi sistem pengukuran kinerja dengan proses scoring system menggunakan metode OMAX menunjukkan nilai current performance indicator yang telah dicapai oleh PDAM Tirta Moedal Semarang adalah sebesar 75,1 %. Hasil pengukuran menjadi landasan pihak manajemen mengevaluasi dan menentukan rencana kerja perbaikan sehingga harapan dari semua stakeholder dapat terpenuhi Kata kunci : Pengukuran Kinerja, Performance Prism, PDAM Tirta Moedal Semarang   Abstract This study describes the results of research on the performance measurement system design PDAM Tirta Moedal Semarang with model Performance Prism. During this PDAM Tirta Moedal not have a performance measurement system. Therefore, it is necessary to design performance measurement systems. From the condition of PDAM Tirta Moedal Semarang, the exact model used is a prism model performance compared to other models. This performance measurement system has 44 KPIs which include 12 customer KPI, KPI 9 employees, 11 KPI owners of capital, supplier KPI 6, KPI 6 governments and communities around the neighborhood. From the results of performance measurement system implementation with the scoring system using the OMAX shows the current performance indicator has been achieved by PDAM Tirta Moedal Semarang amounted to 75.1%. The basis of measurement results to evaluate and determine the management

  1. Co-infection of HIV and HBV in voluntary counseling and testing center in Abidjan

    Directory of Open Access Journals (Sweden)

    Kouassi-M ’Bengue A

    2011-12-01

    Full Text Available Objective: To evaluate the co-infection of hepatitis B virus (HBV and immune deficiency virus (HIV among clients consulting at the Voluntary Counseling and Testing Center (VCT Center of the Institut Pasteur de C ôte d ’Ivoire (IPCI. Methods: A cross-sectional study was conducted from April to June 2010 at the VCT of IPCI. All clients attending the VCT of IPCI for HIV test after having signed the informed consent form were included in the study. Venous blood samples were collected from the clients after an interview. Then the rapid tests for screening of HIV infection (Determine HIV 1/2 of Abbott and Genie II HIV-1/HIV-2, Bio-Rad were performed. As for hepatitis B surface antigen (HBsAg test, it was performed using ELISA test system using Monolisa HBsAg Ultra-Bio-Rad. Results: Of 278 samples analyzed, 30 were positive to antibody against HIV-1, giving a seroprevalence of about 10.8%, and 35 were positive to HBsAg, giving a seroprevalence of 12.6%. As for co-infection of HIV and HBV, it was 7/278 cases about 2.5%. Conclusions: It can be concluded that co-infection of HBV and HIV is relatively low among clients consulting at the VCT of the IPCI. Serological surveillance should be systematic in various HIV testing centers in the country. The use of rapid tests for detection of HBsAg allows a lot of tests to be realized. However, the choice of these tests depends on the evaluation results in reference laboratories and situation on ground.

  2. Pictorial Representation of Self and Illness Measure (PRISM): a graphic instrument to assess suffering in fatigued cancer survivors

    NARCIS (Netherlands)

    Gielissen, M.F.M.; Prins, J.B.; Knoop, H.; Verhagen, S.; Bleijenberg, G.

    2013-01-01

    OBJECTIVE: The Pictorial Representation of Self and Illness Measure (PRISM) measures in a simple, graphic way the burden of suffering due to illness. The question addressed in this study is whether the PRISM is a valid instrument to measure suffering in cancer survivors experiencing severe fatigue.

  3. Hollow optical-fiber based infrared spectroscopy for measurement of blood glucose level by using multi-reflection prism.

    Science.gov (United States)

    Kino, Saiko; Omori, Suguru; Katagiri, Takashi; Matsuura, Yuji

    2016-02-01

    A mid-infrared attenuated total reflection (ATR) spectroscopy system employing hollow optical fibers and a trapezoidal multi-reflection ATR prism has been developed to measure blood glucose levels. Using a multi-reflection prism brought about higher sensitivity, and the flat and wide contact surface of the prism resulted in higher measurement reproducibility. An analysis of in vivo measurements of human inner lip mucosa revealed clear signatures of glucose in the difference spectra between ones taken during the fasting state and ones taken after ingestion of glucose solutions. A calibration plot based on the absorption peak at 1155 cm(-1) that originates from the pyranose ring structure of glucose gave measurement errors less than 20%.

  4. Analytical evaluation of the automated galectin-3 assay on the Abbott ARCHITECT immunoassay instruments.

    Science.gov (United States)

    Gaze, David C; Prante, Christian; Dreier, Jens; Knabbe, Cornelius; Collet, Corinne; Launay, Jean-Marie; Franekova, Janka; Jabor, Antonin; Lennartz, Lieselotte; Shih, Jessie; del Rey, Jose Manuel; Zaninotto, Martina; Plebani, Mario; Collinson, Paul O

    2014-06-01

    Galectin-3 is secreted from macrophages and binds and activates fibroblasts forming collagen. Tissue fibrosis is central to the progression of chronic heart failure (CHF). We performed a European multicentered evaluation of the analytical performance of the two-step routine and Short Turn-Around-Time (STAT) galectin-3 immunoassay on the ARCHITECT i1000SR, i2000SR, and i4000SR (Abbott Laboratories). We evaluated the assay precision and dilution linearity for both routine and STAT assays and compared serum and plasma, and fresh vs. frozen samples. The reference interval and biological variability were also assessed. Measurable samples were compared between ARCHITECT instruments and between the routine and STAT assays and also to a galectin-3 ELISA (BG Medicine). The total assay coefficient of variation (CV%) was 2.3%-6.2% and 1.7%-7.4% for the routine and STAT assays, respectively. Both assays demonstrated linearity up to 120 ng/mL. Galectin-3 concentrations were higher in plasma samples than in serum samples and correlated well between fresh and frozen samples (R=0.997), between the routine and STAT assays, between the ARCHITECT i1000 and i2000 instruments and with the galectin-3 ELISA. The reference interval on 627 apparently healthy individuals (53% male) yielded upper 95th and 97.5th percentiles of 25.2 and 28.4 ng/mL, respectively. Values were significantly lower in subjects younger than 50 years. The galectin-3 routine and STAT assays on the Abbott ARCHITECT instruments demonstrated good analytical performance. Further clinical studies are required to demonstrate the diagnostic and prognostic potential of this novel marker in patients with CHF.

  5. Illusory reversal of causality between touch and vision has no effect on prism adaptation rate

    Directory of Open Access Journals (Sweden)

    Hirokazu eTanaka

    2012-12-01

    Full Text Available Learning, according to Oxford Dictionary, is to gain knowledge or skill by studying, from experience, from being taught, etc. In order to learn from experience, the central nervous system has to decide what action leads to what consequence, and temporal perception plays a critical role in determining the causality between actions and consequences. In motor adaptation, causality between action and consequence is implicitly assumed so that a subject adapts to a new environment based on the consequence caused by her action. Adaptation to visual displacement induced by prisms is a prime example; the visual error signal associated with the motor output contributes to the recovery of accurate reaching, and a delayed feedback of visual error can decrease the adaptation rate. Subjective feeling of temporal order of action and consequence, however, can be modified or even reversed when her sense of simultaneity is manipulated with an artificially delayed feedback. Our previous study (Tanaka, Homma & Imamizu (2011 Exp Brain Res demonstrated that the rate of prism adaptation was unaffected when the subjective delay of visual feedback was shortened. This study asked whether subjects could adapt to prism adaptation and whether the rate of prism adaptation was affected when the subjective temporal order was illusory reversed. Adapting to additional 100 ms delay and its sudden removal caused a positive shift of point of simultaneity in a temporal-order judgment experiment, indicating an illusory reversal of action and consequence. We found that, even in this case, the subjects were able to adapt to prism displacement with the learning rate that was statistically indistinguishable to that without temporal adaptation. This result provides further evidence to the dissociation between conscious temporal perception and motor adaptation.

  6. Illusory Reversal of Causality between Touch and Vision has No Effect on Prism Adaptation Rate.

    Science.gov (United States)

    Tanaka, Hirokazu; Homma, Kazuhiro; Imamizu, Hiroshi

    2012-01-01

    Learning, according to Oxford Dictionary, is "to gain knowledge or skill by studying, from experience, from being taught, etc." In order to learn from experience, the central nervous system has to decide what action leads to what consequence, and temporal perception plays a critical role in determining the causality between actions and consequences. In motor adaptation, causality between action and consequence is implicitly assumed so that a subject adapts to a new environment based on the consequence caused by her action. Adaptation to visual displacement induced by prisms is a prime example; the visual error signal associated with the motor output contributes to the recovery of accurate reaching, and a delayed feedback of visual error can decrease the adaptation rate. Subjective feeling of temporal order of action and consequence, however, can be modified or even reversed when her sense of simultaneity is manipulated with an artificially delayed feedback. Our previous study (Tanaka et al., 2011; Exp. Brain Res.) demonstrated that the rate of prism adaptation was unaffected when the subjective delay of visual feedback was shortened. This study asked whether subjects could adapt to prism adaptation and whether the rate of prism adaptation was affected when the subjective temporal order was illusory reversed. Adapting to additional 100 ms delay and its sudden removal caused a positive shift of point of simultaneity in a temporal order judgment experiment, indicating an illusory reversal of action and consequence. We found that, even in this case, the subjects were able to adapt to prism displacement with the learning rate that was statistically indistinguishable to that without temporal adaptation. This result provides further evidence to the dissociation between conscious temporal perception and motor adaptation.

  7. Evaluation of the analytical performance of the new Abbott RealTime RT-PCRs for the quantitative detection of HCV and HIV-1 RNA

    NARCIS (Netherlands)

    Schutten, Martin; Fries, E; Burghoorn-Maas, C; Niesters, H G M

    2007-01-01

    BACKGROUND: Despite FDA approval and CE marking of commercial tests, manufacturer independent testing of technical aspects is important. OBJECTIVES: To evaluate the analytical performance of the new Abbott RealTime HCV and HIV-1 viral load tests. STUDY DESIGN: Sensitivity, specificity and

  8. Seroprevalence of hepatitis B and hepatitis C markers in adolescents in Southern Brazil Soroprevalência de marcadores de hepatite B e hepatite C em adolescentes no Sul do Brasil

    Directory of Open Access Journals (Sweden)

    Natália Gazzoni Scaraveli

    2011-04-01

    Full Text Available This study was carried out to determine the prevalence of hepatitis B virus (HBV and hepatitis C virus (HCV markers among adolescents aged between 10 and 16 years old, who are elementary school students in the city of Chapecó, Santa Catarina State, Brazil. The study involved a cross-sectional survey that included 418 volunteers, from March to July, 2008. Serology comprised HBsAg, anti-HBc, anti-HBs and anti-HCV. Tests were performed using automated Microparticle Enzyme Immunosorbant Assay (Abbott, AxSYM System, Wiesbaden, Germany. The prevalence of HBsAg was found to be 0.2% (95%CI: 0.0-1.3, and the prevalence of anti-HBc was found to be 1.4% (95%CI: 0.5-3.1. Regarding anti-HBs, 48.6% had titers greater than 10UI/L. None of the volunteers presented reactive results for anti-HCV. This study showed a low prevalence of HBV and HCV markers of infection and a great number of volunteers immunized against HBV. Finally this study shows the importance of proper health campaigns and policies in reducing those prevalences.Este estudo teve como objetivo determinar a prevalência de marcadores do vírus da hepatite B (HBV e do vírus da hepatite C (HCV entre adolescentes com idade entre 10 e 16 anos, alunos do Ensino Fundamental da cidade de Chapecó, Santa Catarina, Brasil. Trata-se de um estudo transversal incluindo 418 voluntários, realizado entre março e julho de 2008. As análises sorológicas incluíram: HBsAg, anti-HBc, anti-HBs e anti-HCV. Os testes foram realizados em Ensaio Enzimático de Micropartículas (Abbott, AxSYM System, Wiesbaden, Alemanha. A prevalência de HBsAg foi de 0,2% (IC95%: 0,0-1,3, e a prevalência de anti-HBc foi de 1,4% (IC95%: 0,5-3,1. Quanto ao anti-HBs, 48,6% dos voluntários apresentaram títulos maiores que 10UI/L. Nenhum dos voluntários apresentou resultados reativos para anti-HCV. Este estudo demonstrou uma baixa prevalência de marcadores de infecção HBV e HCV e um grande número de voluntários imunizados contra

  9. Radiometric, geometric, and image quality assessment of ALOS AVNIR-2 and PRISM sensors

    Science.gov (United States)

    Saunier, S.; Goryl, P.; Chander, G.; Santer, R.; Bouvet, M.; Collet, B.; Mambimba, A.; Kocaman, Aksakal S.

    2010-01-01

    The Advanced Land Observing Satellite (ALOS) was launched on January 24, 2006, by a Japan Aerospace Exploration Agency (JAXA) H-IIA launcher. It carries three remote-sensing sensors: 1) the Advanced Visible and Near-Infrared Radiometer type 2 (AVNIR-2); 2) the Panchromatic Remote-Sensing Instrument for Stereo Mapping (PRISM); and 3) the Phased-Array type L-band Synthetic Aperture Radar (PALSAR). Within the framework of ALOS Data European Node, as part of the European Space Agency (ESA), the European Space Research Institute worked alongside JAXA to provide contributions to the ALOS commissioning phase plan. This paper summarizes the strategy that was adopted by ESA to define and implement a data verification plan for missions operated by external agencies; these missions are classified by the ESA as third-party missions. The ESA was supported in the design and execution of this plan by GAEL Consultant. The verification of ALOS optical data from PRISM and AVNIR-2 sensors was initiated 4 months after satellite launch, and a team of principal investigators assembled to provide technical expertise. This paper includes a description of the verification plan and summarizes the methodologies that were used for radiometric, geometric, and image quality assessment. The successful completion of the commissioning phase has led to the sensors being declared fit for operations. The consolidated measurements indicate that the radiometric calibration of the AVNIR-2 sensor is stable and agrees with the Landsat-7 Enhanced Thematic Mapper Plus and the Envisat MEdium-Resolution Imaging Spectrometer calibration. The geometrical accuracy of PRISM and AVNIR-2 products improved significantly and remains under control. The PRISM modulation transfer function is monitored for improved characterization.

  10. Diamond-coated ATR prism for infrared absorption spectroscopy of surface-modified diamond nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Remes, Z., E-mail: remes@fzu.cz [Institute of Physics of the ASCR, v.v.i., Cukrovarnicka 10, Praha 6 (Czech Republic); Kozak, H.; Rezek, B.; Ukraintsev, E.; Babchenko, O.; Kromka, A. [Institute of Physics of the ASCR, v.v.i., Cukrovarnicka 10, Praha 6 (Czech Republic); Girard, H.A.; Arnault, J.-C.; Bergonzo, P. [CEA, LIST, Diamond Sensors Laboratory, F-91191 Gif-sur-Yvette (France)

    2013-04-01

    Linear antenna microwave chemical vapor deposition process was used to homogeneously coat a 7 cm long silicon prism by 85 nm thin nanocrystalline diamond (NCD) layer. To show the advantages of the NCD-coated prism for attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) of nanoparticles, we apply diamond nanoparticles (DNPs) of 5 nm nominal size with various surface modifications by a drop-casting of their methanol dispersions. ATR-FTIR spectra of as-received, air-annealed, plasma-oxidized, and plasma-hydrogenated DNPs were measured in the 4000–1500 cm{sup −1} spectral range. The spectra show high spectral resolution, high sensitivity to specific DNP surface moieties, and repeatability. The NCD coating provides mechanical protection against scratching and chemical stability of the surface. Moreover, unlike on bare Si surface, NCD hydrophilic properties enable optically homogeneous coverage by DNPs with some aggregation on submicron scale as evidenced by scanning electron microscopy and atomic force microscopy. Compared to transmission FTIR regime with KBr pellets, direct and uniform deposition of DNPs on NCD-ATR prism significantly simplifies and speeds up the analysis (from days to minutes). We discuss prospects for in situ monitoring of surface modifications and molecular grafting.

  11. Diamond-coated ATR prism for infrared absorption spectroscopy of surface-modified diamond nanoparticles

    Science.gov (United States)

    Remes, Z.; Kozak, H.; Rezek, B.; Ukraintsev, E.; Babchenko, O.; Kromka, A.; Girard, H. A.; Arnault, J.-C.; Bergonzo, P.

    2013-04-01

    Linear antenna microwave chemical vapor deposition process was used to homogeneously coat a 7 cm long silicon prism by 85 nm thin nanocrystalline diamond (NCD) layer. To show the advantages of the NCD-coated prism for attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) of nanoparticles, we apply diamond nanoparticles (DNPs) of 5 nm nominal size with various surface modifications by a drop-casting of their methanol dispersions. ATR-FTIR spectra of as-received, air-annealed, plasma-oxidized, and plasma-hydrogenated DNPs were measured in the 4000-1500 cm-1 spectral range. The spectra show high spectral resolution, high sensitivity to specific DNP surface moieties, and repeatability. The NCD coating provides mechanical protection against scratching and chemical stability of the surface. Moreover, unlike on bare Si surface, NCD hydrophilic properties enable optically homogeneous coverage by DNPs with some aggregation on submicron scale as evidenced by scanning electron microscopy and atomic force microscopy. Compared to transmission FTIR regime with KBr pellets, direct and uniform deposition of DNPs on NCD-ATR prism significantly simplifies and speeds up the analysis (from days to minutes). We discuss prospects for in situ monitoring of surface modifications and molecular grafting.

  12. The PRISM concept for a safe, economic and testable liquid metal fast reactor plant

    International Nuclear Information System (INIS)

    Berglund, R.C.; Salerno, L.N.; Tippets, F.E.

    1987-01-01

    The PRISM project is underway at General Electric as part of an advanced reactor conceptual design program sponsored by the US Department of Energy. The PRISM concept emphasizes inherent safety, modular construction, and factory fabrication. These features are intended to improve the basis for public acceptance, reduce cost,improve licensability, and reduce the risk of schedule delays and cost increases during construction. A PRISM power plant comprises a number of reactor modules. The relatively small size of the reactor module facilitates the use of passive, inherent self-shutdown and shutdown heat removal features for safe accommodation of accidents. These inherent safety features permit simplification and reduction of conventional safety-related systems in the plant. Testing of a full-size prototype reactor module is planned in the late 1990's to demonstrate these inherent safety characteristics. It is intended that the results of the test be used to obtain certification of the design by the US Nuclear Regulatory Commission preparatory to use of reactor modules built to this standard design in licensed commercial plants

  13. A Pilot Evaluation of On-Road Detection Performance by Drivers with Hemianopia Using Oblique Peripheral Prisms

    Directory of Open Access Journals (Sweden)

    Alex R. Bowers

    2012-01-01

    Full Text Available Aims. Homonymous hemianopia (HH, a severe visual consequence of stroke, causes difficulties in detecting obstacles on the nonseeing (blind side. We conducted a pilot study to evaluate the effects of oblique peripheral prisms, a novel development in optical treatments for HH, on detection of unexpected hazards when driving. Methods. Twelve people with complete HH (median 49 years, range 29–68 completed road tests with sham oblique prism glasses (SP and real oblique prism glasses (RP. A masked evaluator rated driving performance along the 25 km routes on busy streets in Ghent, Belgium. Results. The proportion of satisfactory responses to unexpected hazards on the blind side was higher in the RP than the SP drive (80% versus 30%; P=0.001, but similar for unexpected hazards on the seeing side. Conclusions. These pilot data suggest that oblique peripheral prisms may improve responses of people with HH to blindside hazards when driving and provide the basis for a future, larger-sample clinical trial. Testing responses to unexpected hazards in areas of heavy vehicle and pedestrian traffic appears promising as a real-world outcome measure for future evaluations of HH rehabilitation interventions aimed at improving detection when driving.

  14. Prism-coupled Cherenkov phase-matched terahertz wave generation using a DAST crystal.

    Science.gov (United States)

    Suizu, Koji; Shibuya, Takayuki; Uchida, Hirohisa; Kawase, Kodo

    2010-02-15

    Terahertz (THz) wave generation based on nonlinear frequency conversion is a promising method for realizing a tunable monochromatic high-power THz-wave source. Unfortunately, many nonlinear crystals have strong absorption in the THz frequency region. This limits efficient and widely tunable THz-wave generation. The Cherenkov phase-matching method is one of the most promising techniques for overcoming these problems. Here, we propose a prism-coupled Cherenkov phase-matching (PCC-PM) method, in which a prism with a suitable refractive index at THz frequencies is coupled to a nonlinear crystal. This has the following advantages. Many crystals can be used as THz-wave emitters; the phase-matching condition inside the crystal does not have to be observed; the absorption of the crystal does not prevent efficient generation of radiation; and pump sources with arbitrary wavelengths can be employed. Here we demonstrate PCC-PM THz-wave generation using the organic crystal 4-dimethylamino-N-metyl-4-stilbazolium tosylate (DAST) and a Si prism coupler. We obtain THz-wave radiation with tunability of approximately 0.1 to 10 THz and with no deep absorption features resulting from the absorption spectrum of the crystal. The obtained spectra did not depend on the pump wavelength in the range 1300 to 1450 nm. This simple technique shows promise for generating THz radiation using a wide variety of nonlinear crystals.

  15. Evidence of a Biological Control over Origin, Growth and End of the Calcite Prisms in the Shells of Pinctada margaritifera (Pelecypod, Pterioidea

    Directory of Open Access Journals (Sweden)

    Jean-Pierre Cuif

    2014-12-01

    Full Text Available Consistently classified among the references for calcite simple prisms, the microstructural units that form the outer layer of the Pinctada margaritifera have been investigated through a series of morphological, crystallographical and biochemical characterizations. It is often said that the polygonal transverse shape of the prisms result from the competition for space between adjacent crystals. In contrast to this classical scheme the Pinctada prisms appear to be composed of four successive developmental stages from the concentrically growing disks on the internal side of the periostracum to the morphological, structural and compositional changes in both envelopes and mineral components at the end of the prisms. These latest structural and compositional changes predate nacre deposition, so that the end of prism growth is not caused by occurrence of nacre, but by metabolic changes in the secretory epithelium. This sequence makes obvious the permanent biological control exerted by the outer cell layer of the mantle in both organic envelopes and mineralizing organic phases.

  16. Overview of the ANL advanced LMR system thermal-hydraulic test program supporting both GE/PRISM and RI/SAFR

    International Nuclear Information System (INIS)

    Oras, J.J.; Kuzay, T.M.; Kasza, K.E.

    1988-01-01

    Descriptions of the ANL thermal-hydraulic water models of both the PRISM and SAFR reactors are presented, together with results from Phases I and II of the thermal-hydraulic test program. Phenomena discovered during these tests and modeling results are presented. Overall, these efforts demonstrate the acceptable thermal-hydraulic performance of both the PRISM and SAFR concepts

  17. Seroprevalence of hepatitis B and hepatitis C markers among children and adolescents in the south brazilian region: metropolitan area of Florianópolis, Santa Catarina

    Directory of Open Access Journals (Sweden)

    Andréia Royer Voigt

    Full Text Available Hepatitis B and C are important causes of morbidity and mortality worldwide. In Brazil, according to the Ministry of Health, about 15% of population is infected by hepatitis B virus (HBV and less than 1% by hepatitis C virus (HCV. Nevertheless, the age-specific prevalence of HBV and HCV markers remains unknown. This study aimed to determine the seroprevalence of HBV and HCV markers of infection and immunity in children and adolescents between 10 to 16 years old who live in the metropolitan area of Florianópolis, state of Santa Catarina, South of Brazil. Three hundred and eighty four individuals were enrolled in this study. Serological markers for HBV and HCV (HBsAg, total anti-HBc, anti-HBc IgM, anti-HBs and anti-HCV were determined through Microparticle Enzyme Immunosorbant Assay (MEIA - AxSYM System® - by using commercial diagnostic kits (Abbott Laboratories, Abbott Park, Illinois, USA. All 384 adolescents (100% were negative for HBsAg and anti-HBc IgM. Only two (0.52% were positive for total anti-HBc. Among the studied individuals, 226 (58.85% presented titers of anti-HBs > 10.0mIU/mL, 121 (31.51% presented anti HBs < 10.0mIU/mL, and 37 (9.64% did not present titers of anti-HBs. Regarding to anti-HCV, all 384 adolescents (100% presented negative results for this marker. In conclusion, this study showed a low prevalence of HBV and HCV infections. In addition, it was verified a great number of children and adolescents (89.84% who were positive for the immunity marker anti-HBs, implying that the National Immunization Program Protocol for hepatitis B has been effective in the studied region.

  18. Premios Academia Nacional de Medicina deColombia – LABORATORIOS ABBOTT 2011

    Directory of Open Access Journals (Sweden)

    Alfredo Jácome Roca

    2011-10-01

    Full Text Available

    La Academia Nacional de Medicina con la colaboración de Laboratorios Abbott otorgó en noviembre de 2011 la quinta versión del Premio a las Ciencias Médicas, uno en las áreas de ciencias médicas y experimentales y otro en el área de ciencias clínicas. Presentamos aquí algunas notas sobre los trabajos ganadores y los que obtuvieron menciones honoríficas

    El Premio en el área de las Ciencias Básicas lo obtuvieron Carlos Vélez Pardo y Marlene Jiménez del Río, profesores del Grupo de Neurociencias de la Facultad de Medicina de la Universidad de Antioquia en Medellín. El trabajo ganador se tituló: “MECANISMOS MOLECULARES DE PÉRDIDA NEURONAL Y DE CITOPROTECCIÓN EN MODE-LOS IN VITRO E IN VIVO DE LA ENFERMEDAD DE ALZHEIMER Y PARKINSON” [1,2].

  19. PRISM (Polarized Radiation Imaging and Spectroscopy Mission): an extended white paper

    NARCIS (Netherlands)

    André, Philippe; Baccigalupi, Carlo; Banday, Anthony; Barbosa, Domingos; Barreiro, Belen; Bartlett, James; Bartolo, Nicola; Battistelli, Elia; Battye, Richard; Bendo, George; Benoît, Alain; Bernard, Jean-Philippe; Bersanelli, Marco; Béthermin, Matthieu; Bielewicz, Pawel; Bonaldi, Anna; Bouchet, François; Boulanger, François; Brand, Jan; Bucher, Martin; Burigana, Carlo; Cai, Zhen-Yi; Camus, Philippe; Casas, Francisco; Casasola, Viviana; Castex, Guillaume; Challinor, Anthony; Chluba, Jens; Chon, Gayoung; Colafrancesco, Sergio; Comis, Barbara; Cuttaia, Francesco; D'Alessandro, Giuseppe; Da Silva, Antonio; Davis, Richard; de Avillez, Miguel; de Bernardis, Paolo; de Petris, Marco; de Rosa, Adriano; de Zotti, Gianfranco; Delabrouille, Jacques; Désert, François-Xavier; Dickinson, Clive; Diego, Jose Maria; Dunkley, Joanna; Enßlin, Torsten; Errard, Josquin; Falgarone, Edith; Ferreira, Pedro; Ferrière, Katia; Finelli, Fabio; Fletcher, Andrew; Fosalba, Pablo; Fuller, Gary; Galli, Silvia; Ganga, Ken; García-Bellido, Juan; Ghribi, Adnan; Giard, Martin; Giraud-Héraud, Yannick; Gonzalez-Nuevo, Joaquin; Grainge, Keith; Gruppuso, Alessandro; Hall, Alex; Hamilton, Jean-Christophe; Haverkorn, Marijke; Hernandez-Monteagudo, Carlos; Herranz, Diego; Jackson, Mark; Jaffe, Andrew; Khatri, Rishi; Kunz, Martin; Lamagna, Luca; Lattanzi, Massimiliano; Leahy, Paddy; Lesgourgues, Julien; Liguori, Michele; Liuzzo, Elisabetta; Lopez-Caniego, Marcos; Macias-Perez, Juan; Maffei, Bruno; Maino, Davide; Mangilli, Anna; Martinez-Gonzalez, Enrique; Martins, Carlos J. A. P.; Masi, Silvia; Massardi, Marcella; Matarrese, Sabino; Melchiorri, Alessandro; Melin, Jean-Baptiste; Mennella, Aniello; Mignano, Arturo; Miville-Deschênes, Marc-Antoine; Monfardini, Alessandro; Murphy, Anthony; Naselsky, Pavel; Nati, Federico; Natoli, Paolo; Negrello, Mattia; Noviello, Fabio; O'Sullivan, Créidhe; Paci, Francesco; Pagano, Luca; Paladino, Rosita; Palanque-Delabrouille, Nathalie; Paoletti, Daniela; Peiris, Hiranya; Perrotta, Francesca; Piacentini, Francesco; Piat, Michel; Piccirillo, Lucio; Pisano, Giampaolo; Polenta, Gianluca; Pollo, Agnieszka; Ponthieu, Nicolas; Remazeilles, Mathieu; Ricciardi, Sara; Roman, Matthieu; Rosset, Cyrille; Rubino-Martin, Jose-Alberto; Salatino, Maria; Schillaci, Alessandro; Shellard, Paul; Silk, Joseph; Starobinsky, Alexei; Stompor, Radek; Sunyaev, Rashid; Tartari, Andrea; Terenzi, Luca; Toffolatti, Luigi; Tomasi, Maurizio; Trappe, Neil; Tristram, Matthieu; Trombetti, Tiziana; Tucci, Marco; Van de Weijgaert, Rien; Van Tent, Bartjan; Verde, Licia; Vielva, Patricio; Wandelt, Ben; Watson, Robert; Withington, Stafford

    2014-01-01

    PRISM (Polarized Radiation Imaging and Spectroscopy Mission) was proposed to ESA in May 2013 as a large-class mission for investigating within the framework of the ESA Cosmic Vision program a set of important scientific questions that require high resolution, high sensitivity, full-sky observations

  20. Multisite analytical evaluation of the Abbott ARCHITECT cyclosporine assay.

    Science.gov (United States)

    Wallemacq, Pierre; Maine, Gregory T; Berg, Keith; Rosiere, Thomas; Marquet, Pierre; Aimo, Giuseppe; Mengozzi, Giulio; Young, Julianna; Wonigeit, Kurt; Kretschmer, Robert; Wermuth, Bendicht; Schmid, Rainer W

    2010-04-01

    The objective of this study was to evaluate the analytical performance of the Abbott ARCHITECT Cyclosporine (CsA) immunoassay in 7 clinical laboratories in comparison to liquid chromatography/tandem mass spectrometry (LC/MS/MS), Abbott TDx, Cobas Integra 800, and the Dade Dimension Xpand immunoassay. The ARCHITECT assay uses a whole blood specimen, a pretreatment step with organic reagents to precipitate proteins and extract the drug, followed by a 2-step automated immunoassay with magnetic microparticles coated with anti-CsA antibody and an acridinium-CsA tracer. Imprecision testing at the 7 evaluation sites gave a range of total % coefficient of variations of 7.5%-12.2% at 87.5 ng/mL, 6.6%-14.3% at 411 ng/mL, and 5.2%-10.7% at 916 ng/mL. The lower limit of quantification ranged from 12 to 20 ng/mL. Purified CsA metabolites AM1, AM1c, AM4N, AM9, and AM19 were tested in whole blood by the ARCHITECT assay and showed minimal cross-reactivity at all 7 sites. In particular, AM1 and AM9 cross-reactivity in the ARCHITECT assay, ranged from -2.5% to 0.2% and -0.8% to 2.2%, respectively, and was significantly lower than for the TDx assay, in which the values were 3.2% and 16.1%, respectively. Comparable testing of metabolites in the Dade Dimension Xpand assay at 2 evaluation sites showed cross-reactivity to AM4N (6.4% and 6.8%) and AM9 (2.6% and 3.6%) and testing on the Roche Integra 800 showed cross-reactivity to AM1c (2.4%), AM9 (10.7%), and AM19 (2.8%). Cyclosporine International Proficiency Testing Scheme samples, consisting of both pooled specimens from patients receiving CsA therapy as well as whole-blood specimens supplemented with CsA, were tested by the ARCHITECT assay at 6 sites and showed an average bias of -24 to -58 ng/mL versus LC/MSMS CsA and -2 to -37 ng/mL versus AxSYM CsA. Studies were performed with the ARCHITECT CsA assay on patient specimens with the following results: ARCHITECT CsA assay versus LC/MSMS, average bias of 31 ng/mL; ARCHITECT versus the

  1. Experience with basal area estimation by prisms in lodgepole pine.

    Science.gov (United States)

    James M. Trappe

    1957-01-01

    Estimation of basal area by prisms offers intriguing possibilities for reducing time and effort in making stand inventories. Increased inventory efficiency is a particular need in stands that are relatively low in value due to small stems, predominance of low value species or heavy defect. In the Pacific Northwest, lodgepole pine characteristically forms dense low-...

  2. Preapplication safety evaluation report for the Power Reactor Innovative Small Module (PRISM) liquid-metal reactor. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Donoghue, J.E.; Donohew, J.N.; Golub, G.R.; Kenneally, R.M.; Moore, P.B.; Sands, S.P.; Throm, E.D.; Wetzel, B.A. [Nuclear Regulatory Commission, Washington, DC (United States). Associate Directorate for Advanced Reactors and License Renewal

    1994-02-01

    This preapplication safety evaluation report (PSER) presents the results of the preapplication desip review for die Power Reactor Innovative Small Module (PRISM) liquid-mew (sodium)-cooled reactor, Nuclear Regulatory Commission (NRC) Project No. 674. The PRISM conceptual desip was submitted by the US Department of Energy in accordance with the NRC`s ``Statement of Policy for the Regulation of Advanced Nuclear Power Plants`` (51 Federal Register 24643). This policy provides for the early Commission review and interaction with designers and licensees. The PRISM reactor desip is a small, modular, pool-type, liquid-mew (sodium)-cooled reactor. The standard plant design consists of dim identical power blocks with a total electrical output rating of 1395 MWe- Each power block comprises three reactor modules, each with a thermal rating of 471 MWt. Each module is located in its own below-grade silo and is co to its own intermediate heat transport system and steam generator system. The reactors utilize a metallic-type fuel, a ternary alloy of U-Pu-Zr. The design includes passive reactor shutdown and passive decay heat removal features. The PSER is the NRC`s preliminary evaluation of the safety features in the PRISM design, including the projected research and development programs required to support the design and the proposed testing needs. Because the NRC review was based on a conceptual design, the PSER did not result in an approval of the design. Instead it identified certain key safety issues, provided some guidance on applicable licensing criteria, assessed the adequacy of the preapplicant`s research and development programs, and concluded that no obvious impediments to licensing the PRISM design had been identified.

  3. HCV-RNA quantification in liver bioptic samples and extrahepatic compartments, using the abbott RealTime HCV assay.

    Science.gov (United States)

    Antonucci, FrancescoPaolo; Cento, Valeria; Sorbo, Maria Chiara; Manuelli, Matteo Ciancio; Lenci, Ilaria; Sforza, Daniele; Di Carlo, Domenico; Milana, Martina; Manzia, Tommaso Maria; Angelico, Mario; Tisone, Giuseppe; Perno, Carlo Federico; Ceccherini-Silberstein, Francesca

    2017-08-01

    We evaluated the performance of a rapid method to quantify HCV-RNA in the hepatic and extrahepatic compartments, by using for the first time the Abbott RealTime HCV-assay. Non-tumoral (NT), tumoral (TT) liver samples, lymph nodes and ascitic fluid from patients undergoing orthotopic-liver-transplantation (N=18) or liver resection (N=4) were used for the HCV-RNA quantification; 5/22 patients were tested after or during direct acting antivirals (DAA) treatment. Total RNA and DNA quantification from tissue-biopsies allowed normalization of HCV-RNA concentrations in IU/μg of total RNA and IU/10 6 liver-cells, respectively. HCV-RNA was successfully quantified with high reliability in liver biopsies, lymph nodes and ascitic fluid samples. Among the 17 untreated patients, a positive and significant HCV-RNA correlation between serum and NT liver-samples was observed (Pearson: rho=0.544, p=0.024). Three DAA-treated patients were HCV-RNA "undetectable" in serum, but still "detectable" in all tested liver-tissues. Differently, only one DAA-treated patient, tested after sustained-virological-response, showed HCV-RNA "undetectability" in liver-tissue. HCV-RNA was successfully quantified with high reliability in liver bioptic samples and extrahepatic compartments, even when HCV-RNA was "undetectable" in serum. Abbott RealTime HCV-assay is a good diagnostic tool for HCV quantification in intra- and extra-hepatic compartments, whenever a bioptic sample is available. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Evaluation of the performance of Abbott m2000 and Roche COBAS Ampliprep/COBAS Taqman assays for HIV-1 viral load determination using dried blood spots and dried plasma spots in Kenya.

    Science.gov (United States)

    Zeh, Clement; Ndiege, Kenneth; Inzaule, Seth; Achieng, Rebecca; Williamson, John; Chih-Wei Chang, Joy; Ellenberger, Dennis; Nkengasong, John

    2017-01-01

    Routine HIV viral load testing is not widely accessible in most resource-limited settings, including Kenya. To increase access to viral load testing, alternative sample types like dried blood spots (DBS), which overcome the logistic barriers associated with plasma separation and cold chain shipment need to be considered and evaluated. The current study evaluated matched dried blood spots (DBS) and dried plasma spots (DPS) against plasma using the Abbott M 2000 (Abbott) and Roche Cobas Ampliprep/Cobas TaqMan (CAP/CTM) quantitative viral load assays in western Kenya. Matched plasma DBS and DPS were obtained from 200 HIV-1 infected antiretroviral treatment (ART)-experienced patients attending patient support centers in Western Kenya. Standard quantitative assay performance parameters with accompanying 95% confidence intervals (CI) were assessed at the assays lower detection limit (400cps/ml for CAP/CTM and 550cps/ml for Abbott) using SAS version 9.2. Receiver operating curves (ROC) were further used to assess viral-load thresholds with best assay performance (reference assay CAP/CTM plasma). Using the Abbott test, the sensitivity and specificity, respectively, for DPS were (97.3%, [95%CI: 93.2-99.2] and 98.1% [95%CI: 89.7-100]) and those for DBS (93.9% [95%CI: 88.8-97.2] and 88.0% [95%CI: 82.2-92.4]). The correlation and agreement using paired plasma and DPS/DBS were strong, with r2 = 90.5 and rc = 68.1. The Bland-Altman relative percent change was 95.3 for DPS, (95%CI: 90.4-97.7) and 73.6 (95%CI: 51.6-86.5) for DBS. Using the CAP/CTM assay, the sensitivity for DBS was significantly higher compared to DPS (100.0% [95% CI: 97.6-100.0] vs. 94.7% [95%CI: 89.8-97.7]), while the specificity for DBS was lower: 4%, [95% CI: 0.4-13.7] compared to DPS: 94.0%, [95% CI: 83.5-98.7]. When compared under different clinical relevant thresholds, the accuracy for the Abbott assay was 95% at the 1000cps/ml cut-off with a sensitivity and specificity of 96.6% [95% CI 91.8-98.7] and 90

  5. Regional Variation of CH4 and N2 Production Processes in the Deep Aquifers of an Accretionary Prism.

    Science.gov (United States)

    Matsushita, Makoto; Ishikawa, Shugo; Nagai, Kazushige; Hirata, Yuichiro; Ozawa, Kunio; Mitsunobu, Satoshi; Kimura, Hiroyuki

    2016-09-29

    Accretionary prisms are mainly composed of ancient marine sediment scraped from the subducting oceanic plate at a convergent plate boundary. Large amounts of anaerobic groundwater and natural gas, mainly methane (CH4) and nitrogen gas (N2), are present in the deep aquifers associated with an accretionary prism; however, the origins of these gases are poorly understood. We herein revealed regional variations in CH4 and N2 production processes in deep aquifers in the accretionary prism in Southwest Japan, known as the Shimanto Belt. Stable carbon isotopic and microbiological analyses suggested that CH4 is produced through the non-biological thermal decomposition of organic matter in the deep aquifers in the coastal area near the convergent plate boundary, whereas a syntrophic consortium of hydrogen (H2)-producing fermentative bacteria and H2-utilizing methanogens contributes to the significant production of CH4 observed in deep aquifers in midland and mountainous areas associated with the accretionary prism. Our results also demonstrated that N2 production through the anaerobic oxidation of organic matter by denitrifying bacteria is particularly prevalent in deep aquifers in mountainous areas in which groundwater is affected by rainfall.

  6. Progress on PRISM, an inherently safe, economic, and testable advanced liquid metal reactor

    International Nuclear Information System (INIS)

    Tippets, F.E.; Salerno, L.N.; Boardman, C.E.; Kwant, W.; Murata, R.E.; Snyder, C.R.

    1987-01-01

    This paper reports progress on the design of PRISM (Power Reactor Inherently Safe Module) under the DOE-sponsored innovative reactor program now in its third year at General Electric. The purpose of this program is to develop a design for an inherently safe, reliable, and marketable liquid metal fast reactor power plant. The PRISM design approach includes the following key elements: Compact sodium-cooled pool-type reactor modules that are sized to enable factory fabrication, economical shipment to inland as well as water-side sites, and economical full-scale prototype testing for design certification; Nuclear safety-related envelope limited to the reactor modules and their service systems; Inherent, passive shutdown heat removal for loss-of-cooling events; Inherent, passive reactivity shutdown for failure-to-scram events

  7. An in-house assay for BK polyomavirus quantification using the Abbott m2000 RealTime system.

    Science.gov (United States)

    Muldrew, Kenneth L; Lovett, Jennie L

    2013-11-01

    BK polyomavirus (BKPyV) quantification is useful for monitoring renal transplant patient response to therapy. The Abbott m2000 RealTime System employed by some clinical laboratories to perform US Food and Drug Administration-approved assays can also be used to develop in-house assays such as the one presented here. This study aimed to validate an in-house quantitative real-time PCR assay targeting the BKPyV major capsid VP1 gene for assessment of viral load using the Abbott m2000 RealTime System. BKPyV load was measured in 95 urine and plasma samples previously tested for BKPyV by one of three laboratories (46 BKPyV-positive samples consisting of 35 plasma and 11 urine samples; 49 samples negative for BKPyV consisting of 47 plasma and two urine samples). Two additional plasma specimens from the College of American Pathologists proficiency testing survey were also analysed. Precision studies were performed by diluting a high-viral-titre patient sample into BKPyV-negative pooled plasma to create high-positive (6.16 log10 copies ml(-1)) and low-positive (3.16 log10 copies ml(-1)) samples. For precision studies of inter-assay variability, a high-positive (7.0 log10 copies ml(-1)) and a low-positive (3.0 log10 copies ml(-1)) sample were measured in 20 separate runs. The assay's limit of quantification and limit of detection were 2.70 and 2.25 log10 copies ml(-1), respectively. The assay was linear from 2.70 to 9.26 log10 copies ml(-1). Of the 48 known positives, 43 were detected as positive, with three reported by the reference laboratory as values lower than the limit of detection. Two known positives at 3.27 and 3.80 log10 copies ml(-1) tested negative by the m2000 BKPyV assay. Of the 49 known negative samples, 48 were negative by the m2000 BKPyV load assay, with one sample confirmed positive by a reference laboratory. Qualitative analysis prior to discrepancy testing demonstrated a sensitivity of 89.58 % and a specificity of 97.96 %. Precision studies

  8. Pictorial Representation of Self and Illness Measure (PRISM): a graphic instrument to assess suffering in fatigued cancer survivors.

    Science.gov (United States)

    Gielissen, Marieke F M; Prins, Judith B; Knoop, Hans; Verhagen, Stans; Bleijenberg, Gijs

    2013-06-01

    The Pictorial Representation of Self and Illness Measure (PRISM) measures in a simple, graphic way the burden of suffering due to illness. The question addressed in this study is whether the PRISM is a valid instrument to measure suffering in cancer survivors experiencing severe fatigue. Quantitative and qualitative data of a previous randomized controlled trial demonstrating the efficacy of cognitive behavior therapy (CBT) especially designed for postcancer fatigue was used to assess convergent validity and sensitivity to change in a sample of 83 cancer survivors. The PRISM, yielding self-illness separation (SIS-fatigue = suffering due to fatigue; SIS-cancer = suffering due to cancer), fatigue severity (Checklist Individual Strength; CIS-fatigue), functional impairment, psychological well-being, quality of life, and coping with the experience of cancer (Impact of Event Scale; IES). Moderate significant correlations were found with the PRISM and the above-mentioned measures. On the basis of SIS scores, the sample was divided into two separate groups: cancer survivors who suffered more because of fatigue and cancer survivors who suffered more because they had cancer in the past. The two groups had different scores on CIS-fatigue and IES, in line with that aspect that caused them the most suffering. The qualitative data confirmed this finding. Participants in the CBT condition demonstrated a significant difference between SIS-fatigue at baseline versus 6 months later compared with those in the waiting list condition. No change of SIS-cancer was found. The PRISM seems to be a valuable tool in fatigue research and clinical practice. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  9. Promoting Resilience in Stress Management for Parents (PRISM-P): An intervention for caregivers of youth with serious illness.

    Science.gov (United States)

    Yi-Frazier, Joyce P; Fladeboe, Kaitlyn; Klein, Victoria; Eaton, Lauren; Wharton, Claire; McCauley, Elizabeth; Rosenberg, Abby R

    2017-09-01

    It is well-known that parental stress and coping impacts the well-being of children with serious illness. The current study aimed to evaluate the feasibility and satisfaction of a novel resilience promoting intervention, the Promoting Resilience in Stress Management Intervention for Parents (PRISM-P) among parents of adolescents and young adults with Type 1 diabetes or cancer. Secondary analyses explored the effect of the PRISM-P on parent-reported resilience and distress. The PRISM-P includes 4 short skills-based modules, delivered in either 2 or 4 separate, individual sessions. English-speaking parents of adolescents with cancer or Type 1 diabetes were eligible. Feasibility was conservatively defined as a completion rate of 80%; satisfaction was qualitatively evaluated based upon parent feedback regarding intervention content, timing, and format. Resilience and distress were assessed pre- and postintervention with the Connor Davidson Resilience Scale and the Kessler-6 Psychological Distress Scale. Twelve of 24 caregivers of youth with diabetes (50%) and 13 of 15 caregivers of youth with cancer (87%) agreed to participate. Nine of 12 (75%) and 9 of 13 (64%) completed all PRISM-P modules, respectively. Among those who completed the intervention, qualitative satisfaction was high. Parent-reported resilience and distress scores improved after the intervention. Effect sizes for both groups indicated a moderate intervention effect. Ultimately, the PRISM-P intervention was well accepted and impactful among parents who completed it. However, attrition rates were higher than anticipated, suggesting alternative or less time-intensive formats may be more feasible. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  10. RESEARCH OF ANTIGEN AND ANTIBODIES FROM RETROVIRUSES, CMV AND HBV AMONG PRISONERS OF THE PENITENTIARY COMPLEX OF THE REGION OF CAMPINAS, SP, BRAZIL

    Directory of Open Access Journals (Sweden)

    Neusa Maria OSTI

    1998-07-01

    Full Text Available Some viruses of the families Retroviridae, such as Human T Lymphotropic Virus (HTLV; Herpesviridae as the Cytomegalovirus (CMV and Hepadnaviridae such as the Hepatitis B Virus (HBV are liable to be co-transmitted with the Human Immunodeficiency Virus (HIV. Since prisoners are exposed to several and important risk factors involved in the transmission of HIV and the above mentioned viruses, male inmates from the penitentiary complex of Campinas, SP, Brazil, including HIV + and HIV - ones, were examined for the presence of HTLV-I and/or II antibodies; IgG and IgM anti-CMV antibodies, and the research of the superficial hepatitis B antigen (HBsAg. The presence of anti-HTLV-I and/or II was determined by the Western Blot (WB technique, whereas IgG and IgM anti-CMV and the search of HBsAg were carried out by the Microparticle Enzyme Immunoassay (MEIA-Abbott Lab.With regard to anti-HTLV-I and/or II, 58.3% (14/24-Number of positive reactions/number of sera examined were reactive among the anti-HIV positive sera. Conversely, only 12.5% (3/24 among the HIV- negative sera showed positive reactions to HTLV-I and/or II antibodies. When looking for IgG anti-CMV percentages of 97.7% (43/44 and 95% (38/40 were obtained for anti-HIV positive and negative sera, respectively. As to IgM anti-CMV antibodies 11.36% (5/44 and 2.5% (1/40 of reactive sera were found for anti-HIV positive and negative, respectively. The HBsAg was found in 12.8% (5/39 of the sera which were anti-HIV positive.Alguns vírus das famílias Retroviridae, tais como, o Vírus do Linfoma Humano de Células T ( HTLV; Herpesviridae, tais como o Vírus Citomegálico (CMV e da Hepatite B (HBV podem ser co-transmitidos com o Vírus da Imunodeficiência Adquirida (HIV. Uma vez que prisioneiros estão expostos a diversos fatores de risco envolvidos na transmissão do HIV e dos vírus acima mencionados, prisioneiros do sexo masculino do Complexo Penitenciário de Campinas, SP, Brasil, incluindo aqueles

  11. Soroprevalência da hepatite B e avaliação da resposta imunológica à vacinação contra a hepatite B por via intramuscular e intradérmica em profissionais de um laboratório de saúde pública Hepatitis B seroprevalence and evaluation of immune response to hepatitis B vaccination using intramuscular and intradermal routes in public health laboratory employees

    Directory of Open Access Journals (Sweden)

    Regina Célia Moreira

    2007-10-01

    Full Text Available OBJETIVOS: Determinar a prevalência dos marcadores da hepatite B (HBsAg e anti-HBs e avaliar a resposta à vacinação contra hepatite B por via intradérmica (ID em profissionais de saúde que não responderam à vacinação por via intramuscular (IM. MÉTODO: Todos os funcionários do Instituto Adolfo Lutz (IAL foram convidados a participar do estudo. Amostras de soro foram colhidas no momento da administração da primeira dose de vacina (Engerix® B e o HBsAg e o anti-HBs foram pesquisados, utilizando-se kits comerciais (Laboratórios Abbott®. Aos funcionários que não responderam à vacinação convencional (três doses por via IM foram oferecidas doses de 5µg da mesma vacina por via ID. RESULTADOS: Foram envolvidos nesse estudo 404 funcionários do IAL, dos quais dois (0,5% eram HBsAg e 42 (10,5%, anti-HBs reagentes. Dos 360 voluntários com sorologia negativa, 316 (87,8% receberam três doses de vacina (IM e, desses, 259 colheram soros para avaliação pós-vacinal. Do total, 242 (93,4% apresentaram anticorpos acima de 10 UI/L após completarem o esquema inicial. Foram administradas duas doses de reforço, porém sete funcionários permaneceram sem resposta imunológica. A vacinação intradérmica foi realizada em cinco voluntários, e todos produziram anticorpos após a utilização dessa via de administração. CONCLUSÕES: A prevalência da hepatite B não foi maior nessa população do que na população geral. A vacinação por via intradérmica pode ser uma boa alternativa na imunização de pessoas que não respondem ao esquema convencional.OBJECTIVES: To determine the prevalence of HBsAg and anti-HBs and to evaluate the response of intradermal hepatitis vaccination in healthcare workers non-responsive to previous repeated intramuscular vaccination. MATERIAL AND METHOD: All of the employees from Instituto Adolfo Lutz were invited to participate on this study. Serum samples were obtained and HBsAg and anti-HBs were detected

  12. Bisecting real and fake body parts: effects of prism adaptation after right brain damage

    Directory of Open Access Journals (Sweden)

    Nadia eBolognini

    2012-06-01

    Full Text Available The representation of body parts holds a special status in the brain, due to their prototypical shape and the contribution of multisensory (visual and somatosensory-proprioceptive information. In a previous study (Sposito et al., 2010, we showed that patients with left unilateral spatial neglect exhibit a rightward bias in setting the mid-point of their left forearm, which becomes larger when bisecting a cylindrical object comparable in size. This body part advantage, found also in control participants, suggests partly different processes for computing the extent of body parts and objects. In this study we tested 16 right-brain-damaged patients, and 10 unimpaired participants, on a manual bisection task of their own (real left forearm, or a size-matched fake forearm. We then explored the effects of adaptation to rightward displacing prism exposure, which brings about leftward aftereffects. We found that all participants showed prism adaptation and aftereffects, with right-brain-damaged patients exhibiting a reduction of the rightward bias for both real and fake forearm, with no overall differences between them. Second, correlation analyses highlighted the role of visual and proprioceptive information for the metrics of body parts. Third, single-patient analyses showed dissociations between real and fake forearm bisections, and the effects of prism adaptation, as well as a more frequent impairment with fake body parts. In sum, the rightward bias shown by right-brain-damaged patients in bisecting body parts is reduced by prism exposure, as other components of the neglect syndrome; discrete spatial representations for real and fake body parts, for which visual and proprioceptive codes play different roles, are likely to exist. Multisensory information seems to render self bodily segments more resistant to the disruption brought about by right-hemisphere injury.

  13. Subscales correlations between MSSS-88 and PRISM scales in evaluation of spasticity for patients with multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Knežević Tatjana

    2017-01-01

    Full Text Available Introduction/Objective. Patient-reported outcomes have been recognized as an important way of assessing health and well-being of patients with multiple sclerosis (MS. The aim of the study is to determine the correlation between different subscales of Patient-Reported Impact of Spasticity Measure (PRISM and Multiple Sclerosis Spasticity Scale (MSSS-88 scales in the estimation of spasticity influence on different domains Methods. The study is a cross-sectional observational study. MSSS-88 and PRISM scales were analyzed in five domains (body-function domain, activity domain, participation domain, personal factors/wellbeing domain, and hypothesis. For statistical interpretation of the correlation we performed the Spearman’s ρ-test, concurrent validity, divergent validity, and the linear regression model. Results. We found a significant correlation between subscales of evaluated MSSS-88 and PRISM scales for body domains; the highest correlation was between the need for assistance/positioning (NA/P and walking (W. Spasticity has the weakest correlation with the need for intervention (NI. The presence of pain has a negative impact and significant positive correlation between pain discomfort and NI. In the domain of body function for males, there was a non-significant correlation between muscle spasms and NI. The same applies for social functioning and social embarrassment domains, as well as for emotional health and psychological agitation for personal factors / wellbeing domain. The differences between genders of MS patients persist in different domains; muscle spasms are strong predictors for NI, and body movement is a strong predictor versus W for NA/P. Conclusion. MSSS-88 and PRISM scales can be considered reliable in measuring different domains of disability for MS patients with spasticity. Because it is shorter, quicker, and simple to use, it is concluded that the PRISM scale can successfully compete with and replace the MSSS-88 scale in

  14. Risk of fall (RoF) intervention by affecting visual egocenter through gait analysis and yoked prisms.

    Science.gov (United States)

    Padula, William V; Subramanian, Prem; Spurling, April; Jenness, Jonathan

    2015-01-01

    Following a neurologic event such as traumatic brain injury (TBI), cerebrovascular accident (CVA), and chronic neurological conditions including Parkinson's disease, multiple sclerosis, and cerebral palsy a shift in the visual midline (egocenter) can directly affect posture, balance and spatial orientation. As a consequence, this increases the risk of fall (RoF) and injury that imposes a major financial burden on the public health system. To determine if there is a statistically significant change in balance with the intervention of yoked prisms to reduce the risk of fall in subjects with neurological impairments. Ambulation of thirty-six subjects was evaluated on a pressure sensitive mat before and after intervention with yoked prisms. Changes in gait and balance were analyzed in the anterior-posterior (AP) and medial-lateral (ML) axes during ambulation. T-tests for each measure comparing the difference-of-differences to a zero change at baseline returned statistically significant reductions in both AP (p <  0.0001; 95% CI: 1.368- 2.976) and ML (p = 0.0002; 95% CI: 1.472- 4.173) imbalances using specifically directed yoked prisms to correct the visual midline deviation. These findings demonstrate that yoked prisms have the potential to provide a cost-effective means to restore the visual midline thereby improving balance, reduce RoF and subsequent injury.

  15. Rapid growth of ZnO hexagonal prism crystals by direct microwave heating

    Institute of Scientific and Technical Information of China (English)

    ZHU Zhenqi; ZHOU Jian; LIU Guizhen; REN Zhiguo

    2008-01-01

    ZnO hexagonal prism crystals were synthesized from ZnO powders by microwave heating in a short time (within 20 min) without any metal catalyst or transport agent.Zinc oxide raw materials were made by evaporating from the high-temperature zone in an enclosure atmosphere and crystals were grown on the self-source substrate.The inherent asymmetry in microwave heating provides the temperature gradient for crystal growth.Substrate and temperature distribution in the oven show significant effects on the growth of the ZnO crystal.The morphologies demonstrate that these samples are pure hexagonal prism crystals with maximum 80 μm in diameter and 600 μm in length,which possess a well faceted end and side surface.X-ray diffraction (XRD) reveals that these samples are pure crystals.The photoluminescence (PL) exhibits strong ultraviolet emission at room temperature,indicating potential applications for short-wave light-emitting photonic devices.

  16. PERANCANGAN DAN IMPLEMENTASI SISTEM PENGUKURAN KINERJA DENGAN METODE PERFORMANCE PRISM (Studi Kasus pada Hotel X

    Directory of Open Access Journals (Sweden)

    Iwan Vanany

    2004-01-01

    Full Text Available This article described a result of research design of performance measurement system in hotel business with Performance Prism Model. As long as, performance measurement system at hotel X not yet representatived organization performance according to comprehensif and integrated. Because of needed redesign performance measurement system with new model. From the objective condition of hotel X, Performance Prism model more representative than others. The result of design described that stakeholder in hotel X such as: customer, employee, supplier, owner and investor, and regulator and community. From the performance measurement system design are obtained 36 types Key Performance Indicator (KPI such as: 6 KPI of customer, 9 KPI of staff manajerial, 9 KPI of staff operational, 4 KPI of supplier, 3 KPI of investor, and 5 KPI of regulator & community. Result of implementation performance measurement system with scoring system indicates that the amount of scor current performance indicator is 50,75%. Result of measurement can be based management act evaluation and choice planning improvement organization and all Stakeholder requirements must be request. Abstract in Bahasa Indonesia : Artikel ini menguraikan hasil penelitian perancangan sistem pengukuran kinerja pada sebuah perusahaan dalam bisnis hotel dengan model Performance Prism. Selama ini, sistem pengukuran kinerja di Hotel X belum merepresentasikan kinerja organisasi secara komprehensif dan integratif. Oleh karena itu, perlu dilakukan perancangan kembali sistem pengukuran kinerjanya. Dari kondisi objektif hotel X, model yang tepat digunakan adalah model Performance Prism dibanding model lain. Hasil rancangan menunjukkan bahwa stakeholder hotel X meliputi: konsumen, tenaga kerja, supplier, pemilik/investor, serta pemerintah dan masyarakat sekitar lingkungan hotel. Sistem pengukuran kinerja memuat 36 KPI yang meliputi 6 KPI konsumen, 9 KPI staff manajerial, 9 KPI staff operasional, 4 KPI supplier, 3

  17. Improving detection tools for the emerald ash borer (Coleoptera: Buprestidae): comparison of prism and multifunnel traps at varying population densities.

    Science.gov (United States)

    Francese, Joseph A; Rietz, Michael L; Crook, Damon J; Fraser, Ivich; Lance, David R; Mastro, Victor C

    2013-12-01

    The current emerald ash borer survey trap used in the United States is a prism trap constructed from a stock purple corrugated plastic. In recent years, several colors (particularly shades of green and purple) have been shown to be more attractive to the emerald ash borer than this stock color. Our goal was to determine if plastics produced with these colors and incorporated into prism traps can improve and serve as a new alternative to plastics already in use for the emerald ash borer survey. The plastics were tested in moderate to heavily infested areas in Michigan in two initial studies to test their effectiveness at catching the emerald ash borer. Because results from studies performed in heavily infested sites may not always correspond with what is found along the edges of the infestation, we compared trap catch and detection rates (recording at least one catch on a trap over the course of the entire trapping season) of several trap types and colors at sites outside the core of the currently known emerald ash borer infestation in a nine-state detection tool comparison study. Two of the new plastics, a (Sabic) purple and a medium-dark (Sabic) green were incorporated into prism traps and tested alongside a standard purple prism trap and a green multifunnel trap. In areas with lower emerald ash borer density, the new purple (Sabic) corrugated plastic caught more beetles than the current purple prism trap, as well as more than the medium-dark green (Sabic) prism and green multifunnel traps. Sabic purple traps in the detection tools comparison study recorded a detection rate of 86% compared with 73, 66, and 58% for the standard purple, Sabic green, and green multifunnel traps, respectively. These detection rates were reduced to 80, 63, 55, and 46%, respectively, at low emerald ash borer density sites.

  18. High-precision angle sensor based on a Köster’s prism with absolute zero-point

    Science.gov (United States)

    Ullmann, V.; Oertel, E.; Manske, E.

    2018-06-01

    In this publication, a novel approach will be presented to use a compact white-light interferometer based on a Köster’s prism for angle measurements. Experiments show that the resolution of this angle interferometer is in the range of a commercial digital autocollimator, with a focal length of f  =  300 mm, but with clearly reduced signal noise and without overshoot artifacts in the signal caused by digital filters. The angle detection of the reference mirror in the Köster’s interferometer is based on analysing the rotation angle of the fringe pattern, which is projected on a CMOS-matrix. The fringe pattern is generated by two displaced spherical wave fronts coming from one fiber-coupled white-light source and getting divided into a reference and a measurement beam by the Köster’s prism. The displacement correlates with the reference angle mirror in one linear direction and with the angle aberrations of the prism in the other orthogonal direction on the CMOS sensor. We will present the experimental and optical setup, the method and algorithms for the image-to-angle processing as well as the experimental results obtained in calibration and long-term measurements.

  19. Web-based Tools for Educators: Outreach Activities of the Polar Radar for Ice Sheet Measurements (PRISM) Project

    Science.gov (United States)

    Braaten, D. A.; Holvoet, J. F.; Gogineni, S.

    2003-12-01

    The Radar Systems and Remote Sensing Laboratory at the University of Kansas (KU) has implemented extensive outreach activities focusing on Polar Regions as part of the Polar Radar for Ice Sheet Measurements (PRISM) project. The PRISM project is developing advanced intelligent remote sensing technology that involves radar systems, an autonomous rover, and communications systems to measure detailed ice sheet characteristics, and to determine bed conditions (frozen or wet) below active ice sheets in both Greenland and Antarctica. These measurements will provide a better understanding of the response of polar ice sheets to global climate change and the resulting impact the ice sheets will have on sea level rise. Many of the research and technological development aspects of the PRISM project, such as robotics, radar systems, climate change and exploration of harsh environments, can kindle an excitement and interest in students about science and technology. These topics form the core of our K-12 education and training outreach initiatives, which are designed to capture the imagination of young students, and prompt them to consider an educational path that will lead them to scientific or engineering careers. The K-12 PRISM outreach initiatives are being developed and implemented in a collaboration with the Advanced Learning Technology Program (ALTec) of the High Plains Regional Technology in Education Consortium (HPR*TEC). ALTec is associated with the KU School of Education, and is a well-established educational research center that develops and hosts web tools to enable teachers nationwide to network, collaborate, and share resources with other teachers. An example of an innovative and successful web interface developed by ALTec is called TrackStar. Teachers can use TrackStar over the Web to develop interactive, resource-based lessons (called tracks) on-line for their students. Once developed, tracks are added to the TrackStar database and can be accessed and modified

  20. Applying machine learning methods for characterization of hexagonal prisms from their 2D scattering patterns - an investigation using modelled scattering data

    Science.gov (United States)

    Salawu, Emmanuel Oluwatobi; Hesse, Evelyn; Stopford, Chris; Davey, Neil; Sun, Yi

    2017-11-01

    Better understanding and characterization of cloud particles, whose properties and distributions affect climate and weather, are essential for the understanding of present climate and climate change. Since imaging cloud probes have limitations of optical resolution, especially for small particles (with diameter < 25 μm), instruments like the Small Ice Detector (SID) probes, which capture high-resolution spatial light scattering patterns from individual particles down to 1 μm in size, have been developed. In this work, we have proposed a method using Machine Learning techniques to estimate simulated particles' orientation-averaged projected sizes (PAD) and aspect ratio from their 2D scattering patterns. The two-dimensional light scattering patterns (2DLSP) of hexagonal prisms are computed using the Ray Tracing with Diffraction on Facets (RTDF) model. The 2DLSP cover the same angular range as the SID probes. We generated 2DLSP for 162 hexagonal prisms at 133 orientations for each. In a first step, the 2DLSP were transformed into rotation-invariant Zernike moments (ZMs), which are particularly suitable for analyses of pattern symmetry. Then we used ZMs, summed intensities, and root mean square contrast as inputs to the advanced Machine Learning methods. We created one random forests classifier for predicting prism orientation, 133 orientation-specific (OS) support vector classification models for predicting the prism aspect-ratios, 133 OS support vector regression models for estimating prism sizes, and another 133 OS Support Vector Regression (SVR) models for estimating the size PADs. We have achieved a high accuracy of 0.99 in predicting prism aspect ratios, and a low value of normalized mean square error of 0.004 for estimating the particle's size and size PADs.

  1. Analytical characteristics and comparative evaluation of Aptima HCV quant Dx assay with the Abbott RealTime HCV assay and Roche COBAS AmpliPrep/COBAS TaqMan HCV quantitative test v2.0.

    Science.gov (United States)

    Worlock, A; Blair, D; Hunsicker, M; Le-Nguyen, T; Motta, C; Nguyen, C; Papachristou, E; Pham, J; Williams, A; Vi, M; Vinluan, B; Hatzakis, A

    2017-04-04

    The Aptima HCV Quant Dx assay (Aptima assay) is a fully automated quantitative assay on the Panther® system. This assay is intended for confirmation of diagnosis and monitoring of HCV RNA in plasma and serum specimens. The purpose of the testing described in this paper was to evaluate the performance of the Aptima assay. The analytical sensitivity, analytical specificity, precision, and linearity of the Aptima assay were assessed. The performance of the Aptima assay was compared to two commercially available HCV assays; the Abbott RealTime HCV assay (Abbott assay, Abbott Labs Illinois, USA) and the Roche COBAS Ampliprep/COBAS Taqman HCV Quantitative Test v2.0 (Roche Assay, Roche Molecular Systems, Pleasanton CA, USA). The 95% Lower Limit of Detection (LoD) of the assay was determined from dilutions of the 2nd HCV WHO International Standard (NIBSC 96/798 genotype 1) and HCV positive clinical specimens in HCV negative human plasma and serum. Probit analysis was performed to generate the 95% predicted detection limits. The Lower Limit of Quantitation (LLoQ) was established for each genotype by diluting clinical specimens and the 2nd HCV WHO International Standard (NIBSC 96/798 genotype 1) in HCV negative human plasma and serum. Specificity was determined using 200 fresh and 536 frozen HCV RNA negative clinical specimens including 370 plasma specimens and 366 serum specimens. Linearity for genotypes 1 to 6 was established by diluting armored RNA or HCV positive clinical specimens in HCV negative serum or plasma from 8.08 log IU/mL to below 1 log IU/mL. Precision was tested using a 10 member panel made by diluting HCV positive clinical specimens or spiking armored RNA into HCV negative plasma and serum. A method comparison was conducted against the Abbott assay using 1058 clinical specimens and against the Roche assay using 608 clinical specimens from HCV infected patients. In addition, agreement between the Roche assay and the Aptima assay using specimens with low

  2. Nonlinear attractor dynamics in the fundamental and extended prism adaptation paradigm

    International Nuclear Information System (INIS)

    Frank, T.D.; Blau, Julia J.C.; Turvey, M.T.

    2009-01-01

    Adaptation and re-adaptation processes are studied in terms of dynamic attractors that evolve and devolve. In doing so, a theoretical account is given for the fundamental observation that adaptation and re-adaptation processes do not exhibit one-trial learning. Moreover, the emergence of the latent aftereffect in the extended prism paradigm is addressed

  3. [Shared decision-making and individualized goal setting - a pilot trial using PRISM (Pictorial Representation of Illness and Self Measure) in psychiatric inpatients].

    Science.gov (United States)

    Büchi, S; Straub, S; Schwager, U

    2010-12-01

    Although there is much talk about shared decision making and individualized goal setting, there is a lack of knowledge and knowhow in their realization in daily clinical practice. There is a lack in tools for easy applicable tools to ameliorate person-centred individualized goal setting processes. In three selected psychiatric inpatients the semistructured, theory driven use of PRISM (Pictorial Representation of Illness and Self Measure) in patients with complex psychiatric problems is presented and discussed. PRISM sustains a person-centred individualized process of goal setting and treatment and reinforces the active participation of patients. The process of visualisation and synchronous documentation is validated positively by patients and clinicians. The visual goal setting requires 30 to 45 minutes. In patients with complex psychiatric illness PRISM was used successfully to ameliorate individual goal setting. Specific effects of PRISM-visualisation are actually evaluated in a randomized controlled trial.

  4. A Concentrator Photovoltaic System Based on a Combination of Prism-Compound Parabolic Concentrators

    Directory of Open Access Journals (Sweden)

    Ngoc Hai Vu

    2016-08-01

    Full Text Available We present a cost-effective concentrating photovoltaic system composed of a prism and a compound parabolic concentrator (P-CPC. In this approach, the primary collector consists of a prism, a solid compound parabolic concentrator (CPC, and a slab waveguide. The prism, which is placed on the input aperture of CPC, directs the incoming sunlight beam to be parallel with the main axes of parabolic rims of CPC. Then, the sunlight is reflected at the parabolic rims and concentrated at the focal point of these parabolas. A slab waveguide is coupled at the output aperture of the CPC to collect focused sunlight beams and to guide them to the solar cell. The optical system was modeled and simulated with commercial ray tracing software (LightTools™. Simulation results show that the optical efficiency of a P-CPC can achieve up to 89%. when the concentration ratio of the P-CPC is fixed at 50. We also determine an optimal geometric structure of P-CPC based on simulation. Because of the simplicity of the P-CPC structure, a lower-cost mass production process is possible. A simulation based on optimal structure of P-CPC was performed and the results also shown that P-CPC has high angular tolerance for input sunlight. The high tolerance of the input angle of sunlight allows P-CPC solar concentrator utilize a single sun tracking system instead of a highly precise dual suntracking system as cost effective solution.

  5. Pressure and Stress Prediction in the Nankai Accretionary Prism: A Critical State Soil Mechanics Porosity-Based Approach

    Science.gov (United States)

    Flemings, Peter B.; Saffer, Demian M.

    2018-02-01

    We predict pressure and stress from porosity in the Nankai accretionary prism with a critical state soil model that describes porosity as a function of mean stress and maximum shear stress, and assumes Coulomb failure within the wedge and uniaxial burial beneath it. At Ocean Drilling Program Sites 1174 and 808, we find that pore pressure in the prism supports 70% to 90% of the overburden (λu = 0.7 to 0.9), for a range of assumed friction angles (5-30°). The prism pore pressure is equal to or greater than that in the underthrust sediments even though the porosity is lower within the prism. The high pore pressures lead to a mechanically weak wedge that supports low maximum shear stress, and this in turn requires very low basal traction to remain consistent with the observed narrowly tapered wedge geometry. We estimate the décollement friction coefficient (μb) to be 0.08-0.38 (ϕb' = 4.6°-21°). Our approach defines a pathway to predict pressure in a wide range of environments from readily observed quantities (e.g., porosity and seismic velocity). Pressure and stress control the form of the Earth's collisional continental margins and play a key role in its greatest earthquakes. However, heretofore, there has been no systematic approach to relate material state (e.g., porosity), pore pressure, and stress in these systems.

  6. COMET and PRISM - Search for Charged Lepton Flavor Violation with Muons

    Energy Technology Data Exchange (ETDEWEB)

    Kuno, Yoshitaka [Department of Physics, Osaka University, Osaka, 560-0043 (Japan)

    2012-04-15

    The experiment (COMET) at J-PARC to search for a charged-lepton-flavor-violating process of muon to electron conversion in a muonic atom is described. Future prospects of an experiment (PRISM) with even higher sensitivity is mentioned. On-going R and D on a highly intense muon source (MuSIC) at Osaka University is presented.

  7. COMET and PRISM - Search for Charged Lepton Flavor Violation with Muons

    International Nuclear Information System (INIS)

    Kuno, Yoshitaka

    2012-01-01

    The experiment (COMET) at J-PARC to search for a charged-lepton-flavor-violating process of muon to electron conversion in a muonic atom is described. Future prospects of an experiment (PRISM) with even higher sensitivity is mentioned. On-going R and D on a highly intense muon source (MuSIC) at Osaka University is presented.

  8. The prevalence of hepatitis B virus markers in a cohort of students in Bangui, Central African Republic.

    Science.gov (United States)

    Komas, Narcisse P; Baï-Sepou, Souleyman; Manirakiza, Alexandre; Léal, Josiane; Béré, Aubin; Le Faou, Alain

    2010-07-29

    Hepatitis B virus (HBV) is the major cause of chronic hepatitis, cirrhosis, and hepatocellular carcinoma. The global epidemiological scenario of HBV infection has been changing rapidly over the last two decades due to an effective immunization programme initiated by the World Health Organization. The objective of this study is to estimate the prevalence of HBV in apparently healthy young people and to identify the risk factors of transmission of the HBV among this population in Bangui. Dried blood Spots from 801 adolescent high school and young adult university students were prepared by spotting a drop of whole blood (4 spots) from the same fingerprick onto Whatman filter paper. A blood sample aliquot eluted from DBS was then processed with commercial ELISA tests (Abbott Murex, Dartfort, UK) to detect HBsAg antigen, Anti-HBc and Anti-HBs antibodies). The overall prevalence was 42.3% for antibody to hepatitis B core antigen, 15.5% for HBsAg of which 1.3% of HBsAg alone. HBV familial antecedents, sexual activity and socioeconomic conditions were the main risk factors of HBV infection encountered in the adolescents and young adults. These results show for the first time the high prevalence of HBV in apparently healthy young people in Bangui. This high prevalence is age- and sex-independent. Transmission risk factors were a familial antecedent of HBV, no utilisation of condoms and public scholarship. To lower HBV prevalence, an adequate program of active screening and vaccination for adolescents and young adults should be implemented, along with a universal immunization program.

  9. Seroprevalence of Hepatitis B surface antigen, antibodies to the Hepatitis C virus, and human immunodeficiency virus in a hospital-based population in Jaipur, Rajasthan

    Directory of Open Access Journals (Sweden)

    Sood Smita

    2010-01-01

    Full Text Available Background: Hepatitis B, hepatitis C, and HIV infections are a serious global and public health problem. To assess the magnitude and dynamics of disease transmission and for its prevention and control, the study of its seroprevalence is important. A private hospital catering to the needs of a large population represents an important center for serological surveys. Available data, at Rajasthan state level, on the seroprevalence of these bloodborne pathogens is also very limited. Objective: A study was undertaken to estimate the seroprevalence of hepatitis B surface antigen (HBsAg and antibodies to hepatitis C (anti-HCV Ab and human immunodeficiency virus (anti-HIV Ab in both the sexes and different age groups in a hospital-based population in Jaipur, Rajasthan. Materials and Methods: Serum samples collected over a period of 14 months from patients attending OPDs and admitted to various IPDs of Fortis Escorts Hospital, Jaipur, were subjected within the hospital-based lab for the detection of HBsAg and anti-HCV Ab and anti-HIV Ab using rapid card tests. This was followed by further confirmation of all reactive samples by a microparticle enzyme immunoassay (Abbott AxSYM at Super Religare Laboratories (formerly SRL Ranbaxy Reference Lab, Mumbai. Results: The seroprevalence of HBsAg was found to be 0.87%, of anti-HCV Ab as 0.28%, and of anti-HIV Ab as 0.35%. Conclusion: The study throws light on the magnitude of viral transmission in the community in the state of Rajasthan and provides a reference for future studies.

  10. The prevalence of hepatitis B virus markers in a cohort of students in Bangui, Central African Republic

    Directory of Open Access Journals (Sweden)

    Béré Aubin

    2010-07-01

    Full Text Available Abstract Background Hepatitis B virus (HBV is the major cause of chronic hepatitis, cirrhosis, and hepatocellular carcinoma. The global epidemiological scenario of HBV infection has been changing rapidly over the last two decades due to an effective immunization programme initiated by the World Health Organization. The objective of this study is to estimate the prevalence of HBV in apparently healthy young people and to identify the risk factors of transmission of the HBV among this population in Bangui. Methods Dried blood Spots from 801 adolescent high school and young adult university students were prepared by spotting a drop of whole blood (4 spots from the same fingerprick onto Whatman filter paper. A blood sample aliquot eluted from DBS was then processed with commercial ELISA tests (Abbott Murex, Dartfort, UK to detect HBsAg antigen, Anti-HBc and Anti-HBs antibodies. Results The overall prevalence was 42.3% for antibody to hepatitis B core antigen, 15.5% for HBsAg of which 1.3% of HBsAg alone. HBV familial antecedents, sexual activity and socioeconomic conditions were the main risk factors of HBV infection encountered in the adolescents and young adults. Conclusion These results show for the first time the high prevalence of HBV in apparently healthy young people in Bangui. This high prevalence is age- and sex-independent. Transmission risk factors were a familial antecedent of HBV, no utilisation of condoms and public scholarship. To lower HBV prevalence, an adequate program of active screening and vaccination for adolescents and young adults should be implemented, along with a universal immunization program.

  11. The Prism Plastic Calorimeter (PPC)

    CERN Multimedia

    2002-01-01

    This proposal supports two goals: \\\\ \\\\ First goal:~~Demonstrate that current, widely used plastic technologies allow to design Prism Plastic Calorimeter~(PPC) towers with a new ``liquid crystal'' type plastic called Vectra. It will be shown that this technique meets the requirements for a LHC calorimeter with warm liquids: safety, hermeticity, hadronic compensation, resolution and time response. \\\\ \\\\ Second goal:~~Describe how one can design a warm liquid calorimeter integrated into a LHC detector and to list the advantages of the PPC: low price, minimum of mechanical structures, minimum of dead space, easiness of mechanical assembly, accessibility to the electronics, possibility to recirculate the liquid. The absorber and the electronic being outside of the liquid and easily accessible, one has maximum flexibility to define them. \\\\ \\\\ The R&D program, we define here aims at showing the feasibility of these new ideas by building nine towers of twenty gaps and exposing them to electron and hadron beams.

  12. Indirect versus direct feedback in computer-based Prism Adaptation Therapy

    DEFF Research Database (Denmark)

    Wilms, Inge Linda; Rytter, Hana Malá

    2010-01-01

    Prism Adaptation Therapy (PAT) is an intervention method in the treatment of the attention disorder neglect (Frassinetti, Angeli, Meneghello, Avanzi, & Ladavas, 2002; Rossetti, et al., 1998). The aim of this study was to investigate whether one session of PAT using a computer-attached touchscreen...... in the aftereffect. The findings have direct implications for future implementations of computer-based methods of treatment of visuospatial disorders and computer-assisted rehabilitation in general....

  13. Molecular detection and confirmation of Neisseria gonorrhoeae in urogenital and extragenital specimens using the Abbott CT/NG RealTime assay and an in-house assay targeting the porA pseudogene.

    LENUS (Irish Health Repository)

    Walsh, A

    2011-04-01

    Culture for detection of Neisseria gonorrhoeae (NG) is being replaced by molecular assays, but difficulties are observed with false positive and negatives results, especially for extragenital samples. This study evaluates the Abbott CT\\/NG Real-Time assay and a real-time porA pseudogene assay. Samples (n = 600) from a mixed prevalence Irish population include 164 male urines with corresponding urethral swabs, 58 endocervical swabs, 173 male pharyngeal swabs, 205 male rectal swabs, 36 NG clinical isolates and 26 commensal Neisseria species isolates. There was a 100% concordance between the Abbott CT\\/NG Real-Time and the porA assay. The positivity rate was 1.2%, 1.7%, 8.1% and 5.8% for FVU\\/urethral swabs, endocervical, pharyngeal and rectal swabs, respectively. These results were compared to culture and discrepancies were found with nine pharyngeal and three rectal swabs. Seven of the 12 discrepant positive samples were sequenced and were confirmed "true positives". The sensitivity and specificity of the molecular assays was 100%. The sensitivity of the culture-based testing was 100% for urogenital samples but 36% and 75% for pharyngeal and rectal swabs, respectively. The combined Abbott CT\\/NG and porA assays provide a valuable alternative to culture and also generate a significant increase in the diagnosis of pharyngeal and rectal NG infection.

  14. PRISM (Polarized Radiation Imaging and Spectroscopy Mission): an extended white paper

    Energy Technology Data Exchange (ETDEWEB)

    André, Philippe [Laboratoire d' Astrophysique de Paris-Saclay, Gif-sur-Yvette Cedex (France); Baccigalupi, Carlo; Bielewicz, Pawel [SISSA, Via Bonomea 265, 34136, Trieste (Italy); Banday, Anthony [Université de Toulouse, UPS-OMP, IRAP, F-31028 Toulouse cedex 4 (France); Barbosa, Domingos [Grupo de Radio Astronomia Basic Sciences and Enabling Technologies Instituto de Telecomunicações, Campus Universitario de Santiago, 3810-193 Aveiro (Portugal); Barreiro, Belen [Instituto de Fìsica de Cantabria (CSIC-Universidad de Cantabria) Avda. de los Castros s/n, 39005 Santander (Spain); Bartlett, James [APC, AstroParticule et Cosmologie, Université Paris Diderot, CNRS/IN2P3, CEA/lrfu, Observatoire de Paris, Sorbonne Paris, Cité, 10, rue Alice Domon et Léonie Duquet, 75205 Paris Cedex 13 (France); Bartolo, Nicola [Dipartimento di Fisica e Astronomia ' ' G. Galilei" , Università degli studi di Padova, via Marzolo 8, I-35131, Padova (Italy); Battistelli, Elia [Dipartimento di Fisica, Università di Roma La Sapienza, P.le A. Moro 2, 00185 Roma (Italy); Battye, Richard; Bonaldi, Anna [Jordell Bank Centre for Astrophysics, School of Physics and Astronomy, University of Manchester, Oxford Road, Manchester M13 9PL (United Kingdom); Bendo, George [U.K. ALMA Regional Centre Node, Jordell Bank Centre for Astrophysics, School of Physics and Astronomy, University of Manchester, Oxford Road, Manchester M13 9PL (United Kingdom); Benoȋt, Alain [Physics and Astronomy, University of Manchester, Oxford Road, Manchester M13 9PL (United Kingdom); Bernard, Jean-Philippe [CNRS, IRAP, 9 Av. colonel Roche, BP 44346, F-31028 Toulouse cedex 4 (France); Bersanelli, Marco [Dipartimento di Fisica, Università degli Studi di Milano, Via Celoria, 16, Milano (Italy); Béthermin, Matthieu, E-mail: naselsky@nbi.dk [European Southern Observatory, Karl-Schwarzschild-Str. 2, 85748 Garching (Germany); and others

    2014-02-01

    PRISM (Polarized Radiation Imaging and Spectroscopy Mission) was proposed to ESA in May 2013 as a large-class mission for investigating within the framework of the ESA Cosmic Vision program a set of important scientific questions that require high resolution, high sensitivity, full-sky observations of the sky emission at wavelengths ranging from millimeter-wave to the far-infrared. PRISM's main objective is to explore the distant universe, probing cosmic history from very early times until now as well as the structures, distribution of matter, and velocity flows throughout our Hubble volume. PRISM will survey the full sky in a large number of frequency bands in both intensity and polarization and will measure the absolute spectrum of sky emission more than three orders of magnitude better than COBE FIRAS. The data obtained will allow us to precisely measure the absolute sky brightness and polarization of all the components of the sky emission in the observed frequency range, separating the primordial and extragalactic components cleanly from the galactic and zodiacal light emissions. The aim of this Extended White Paper is to provide a more detailed overview of the highlights of the new science that will be made possible by PRISM, which include: (1) the ultimate galaxy cluster survey using the Sunyaev-Zeldovich (SZ) effect, detecting approximately 10{sup 6} clusters extending to large redshift, including a characterization of the gas temperature of the brightest ones (through the relativistic corrections to the classic SZ template) as well as a peculiar velocity survey using the kinetic SZ effect that comprises our entire Hubble volume; (2) a detailed characterization of the properties and evolution of dusty galaxies, where the most of the star formation in the universe took place, the faintest population of which constitute the diffuse CIB (Cosmic Infrared Background); (3) a characterization of the B modes from primordial gravity waves generated during

  15. Prism adaptation does not alter object-based attention in healthy participants [v1; ref status: indexed, http://f1000r.es/210

    Directory of Open Access Journals (Sweden)

    Janet H. Bultitude

    2013-11-01

    Full Text Available Hemispatial neglect (‘neglect’ is a disabling condition that can follow damage to the right side of the brain, in which patients show difficulty in responding to or orienting towards objects and events that occur on the left side of space. Symptoms of neglect can manifest in both space- and object-based frames of reference. Although patients can show a combination of these two forms of neglect, they are considered separable and have distinct neurological bases. In recent years considerable evidence has emerged to demonstrate that spatial symptoms of neglect can be reduced by an intervention called prism adaptation. Patients point towards objects viewed through prismatic lenses that shift the visual image to the right. Approximately five minutes of repeated pointing results in a leftward recalibration of pointing and improved performance on standard clinical tests for neglect. The understanding of prism adaptation has also been advanced through studies of healthy participants, in whom adaptation to leftward prismatic shifts results in temporary neglect-like performance. Here we examined the effect of prism adaptation on the performance of healthy participants who completed a computerised test of space- and object-based attention. Participants underwent adaptation to leftward- or rightward-shifting prisms, or performed neutral pointing according to a between-groups design. Significant pointing after-effects were found for both prism groups, indicating successful adaptation. In addition, the results of the computerised test revealed larger reaction-time costs associated with shifts of attention between two objects compared to shifts of attention within the same object, replicating previous work. However there were no differences in the performance of the three groups, indicating that prism adaptation did not influence space- or object-based attention for this task. When combined with existing literature, the results are consistent with the

  16. The evolution of the matrix metalloproteinase inhibitor drug discovery program at abbott laboratories.

    Science.gov (United States)

    Wada, Carol K

    2004-01-01

    Matrix metalloproteinases (MMPs) have been implicated in several pathologies. At Abbott Laboratories, the matrix metalloproteinases inhibitor drug discovery program has focused on the discovery of a potent, selective, orally bioavailable MMP inhibitor for the treatment of cancer. The program evolved from early succinate-based inhibitors to utilizing in-house technology such as SAR by NMR to develop a novel class of biaryl hydroxamate MMP inhibitors. The metabolic instability of the biaryl hydroxamates led to the discovery of a new class of N-formylhydroxylamine (retrohydroxamate) biaryl ethers, exemplified by ABT-770 (16). Toxicity issues with this pre-clinical candidate led to the discovery of another novel class of retrohydroxamate MMP inhibitors, the phenoxyphenyl sulfones such as ABT-518 (19j). ABT-518 is a potent, orally bioavailable, selective inhibitor of MMP-2 and 9 over MMP-1 that has been evaluated in Phase I clinical trials in cancer patients.

  17. Influence of the apex angle of a hollow prism made from an ordinary commercial glass plate as a simple refractometer to the accuracy of the refractive index measurement of the edible oil

    Science.gov (United States)

    Idris, N.; Maswati; Yusibani, E.

    2018-05-01

    The influence of the apex angle of a hollow prism used as a simple refractometer to the accuracy of a refractive index measurement of the edible oil samples was studied. The hollow prism was made from an ordinary commercial glass plate with a thickness of 2 mm. The apex angle of the constructed hollow prism was varied. The edible oil sample used in this study was palm oil, namely the packaged, branded oil sample and the bulk oil sample. For measuring the refractive index, the oil sample was filled in the constructed hollow prism, and then a helium-neon laser beam was passed through the oil sample at a certain angle of incidence. The angle of minimum deviation of the transmitted laser He-Ne beam was measured and then was used for calculating the refractive index of the oil sample. The refractive index measurement was made using the hollow prism with different apex angles, ranging from 300 to 600. The measurement accuracy was estimated by comparing the refractive index measured using the hollow prisms to that of obtained using a standard Abbe refractometer. It was found that the refractive index of the edible oil can be measured accurately by using the hollow prism. It was also found that the accuracy of the refractive index measurement significantly changes with the apex angle of the hollow prism. The refractive index values measured using this simple refractometer deviate up to 3,49% from the refractive index value measured using the standard Abbe refractometer, especially when the apex angle of the prism is 30°. The measurement results with high accuracies obtained when using the hollow prisms with apex angles of 450 and 600. The optimum apex angle for the present constructed hollow prism is 450. The refractive index obtained using the hollow prism with the apex angle of 450 is 1,4623 and 1,4438 for the bulk oil and the packed, branded oil samples, respectively. This result suggests that the apex angle of the prism used affects largely the accuracy of the

  18. Performance of the prism reactor's passive decay heat removal system

    International Nuclear Information System (INIS)

    Magee, P.M.; Hunsbedt, A.

    1989-01-01

    The PRISM modular reactor concept has a totally passive safety-grade decay heat removal system referred to as the Reactor Vessel Auxiliary Cooling System (RVACS) that rejects heat from the reactor by radiation and natural convection of air. The system is inherently reliable and is not subject to the failure modes commonly associated with active cooling systems. The thermal performance of RVACS exceeds requirements and significant thermal margins exist. RVACS has been shown to perform its function under many postulated accident conditions. The PRISM power plant is equipped with three methods for shutdown: condenser cooling in conjunction with intermediate sodium and steam generator systems, and auxiliary cooling system (ACS) which removes heat from the steam generator by natural convection of air and transport of heat from the core by natural convection in the primary and intermediate systems, and a safety- grade reactor vessel auxiliary cooling system (RVACS) which removes heat passively from the reactor containment vessel by natural convection of air. The combination of one active and two passive systems provides a highly reliable and economical shutdown heat removal system. This paper provides a summary of the RVACS thermal performance for expected operating conditions and postulated accident events. The supporting experimental work, which substantiates the performance predictions, is also summarized

  19. The application of the right rectangular prism in the process determining the value of terrain correction

    Directory of Open Access Journals (Sweden)

    Odalović Oleg R.

    2015-01-01

    Full Text Available The effects of topographic masses on gravity were determined for the territory of Serbia by using the digital terrain model with resolution of 1 arch second in both directions. For the effect of distant masses, i.e. masses that are out of the territory of Serbia, a global digital model SRTM (Shuttle Radar Topography Mission was used. All the topography masses were divided by using a right rectangle prism and classic terrain corrections was applied. Special attention was dedicated to the curvatures of the Earth surface and singularity points, where equations for first partial derivatives of prism gravity potential are not defined.

  20. On improvement of the series convergence in the problem of the vibrations of orhotropic rectangular prism

    Science.gov (United States)

    Lyashko, A. D.

    2017-11-01

    A new analytical presentation of the solution for steady-state oscillations of orthotopic rectangular prism is found. The corresponding infinite system of linear algebraic equations has been deduced by the superposition method. A countable set of precise eigenfrequencies and elementary eigenforms is found. The identities are found which make it possible to improve the convergence of all the infinite series in the solution of the problem. All the infinite series in presentation of solution are analytically summed up. Numerical calculations of stresses in the rectangular orthotropic prism with a uniform along the border and harmonic in time load on two opposite faces have been performed.

  1. Tectonic and Sedimentation Interactions in the East Caribbean Subduction Zone: AN Overview from the Orinoco Delta to the Barbados Accretionary Prism

    Science.gov (United States)

    Deville, E.

    2011-12-01

    Recent marine geophysical acquisitions and piston-coring allow to better understand the close interactions between the sand-rich Orinoco turbidite system and the compressional structures of the Barbados prism. Because of the morphologic and tectonic control in the east-Caribbean active margin, the Orinoco turbiditic pattern system does not exhibit a classic fan geometry. The sea-floor geometry between the slope of the front of the Barbados prism and the slope of the South-American margin induces the convergence of the turbidite channels toward the abyssal plain, at the front of the accretionary prism. Also, whereas in most passive margins the turbidite systems are organized upstream to downstream as canyon, then channel-levee, then lobes, here, due to the tectonic control, the sedimentary system is organized as channel-levee, then canyons, then channelized lobes. At the edge of the Orinoco platform, the system has multiple sources with several distributaries and downward the channel courses are complex with frequent convergences or divergences that are emphasized by the effects of the undulating seafloor tectonic morphologies associated with active thrust tectonics and mud volcanism. On top of the accretionary prism, turbidite sediments are filling transported piggy-back basins whose timing of sedimentation vs. deformation is complex. Erosion processes are almost absent on the highly subsiding Orinoco platform and in the upper part of the turbidite system. Erosion processes develop mostly between 2000 and 4000 m of water depth, above the compressional structures of the Barbados prism (canyons up to 3 km wide and 300 m deep). In the abyssal plain, turbiditic channels develop on very long distance (> 1000 km) joining the mid-Atlantic channel (sourced mostly by the Amazon), filling several elongated basins corresponding to transform faults (notably the Barracuda Basin), and finally sourcing the Puerto-Rico trench, the deepest morphologic depression of this region

  2. Health-related quality of life and binocular vision in patients with diplopia in acute-onset comitant esotropia with press-on prism improves

    Directory of Open Access Journals (Sweden)

    Qian Wang

    2017-11-01

    Full Text Available AIM: To assess the effect of press-on prisms in patients with acute-onset comitant esotropia and diplopia, focusing primarily on vision-related quality of life and binocular vision. METHODS: Retrospective case-series study. Totally 16 acute-onset comitant esotropia patients with diplopia who received treatment in the Huzhou Central Hospital were included in this study from March 2014 to March 2017. Vision-related quality of life before press-on prism correction and 1mo after press-on prism correction were performed with the Chinese version of the 25-item National Eye Institute Visual Functioning Questionnaire(CHI-NEI-VFQ-25. In each time of follow-up, we made a minute examination, includes worth four dot test and stereo tests. Data was statistically analyzed with paired sample t test, Chi-square test and Fisher's exact test. RESULTS: Except the degree of eye pain, color vision and perimetry, the indicators from CHI-NEI-VFQ-25 table including general health status, overall vision, mental health, social role difficulties, social functional, near activities, distant activities, independency and driving of acute-onset comitant esotropia patients with diplopia were obviously significant improved 1mo after press-on prism correction(PPCONCLUSION: Press-on prism correction may be helpful for binocular vision recovery in acute-onset comitant esotropia patients with diplopia, so as improve the vision-related quality of life.

  3. Pictorial Representation of Illness and Self Measure Revised II (PRISM-RII) - a novel method to assess perceived burden of illness in diabetes patients

    NARCIS (Netherlands)

    Klis, S.; Vingerhoets, A.J.M.M.; de, W.M.; Zandbelt, N.; Snoek, F.J.

    2008-01-01

    Background: The Pictorial Representation of Illness and Self Measure (PRISM) has been introduced as a visual measure of suffering. We explored the validity of a revised version, the PRISM-RII, in diabetes patients as part of the annual review. Methods: Participants were 308 adult outpatients with

  4. Detection of HbsAg and hATIII genetically modified goats (Caprahircus) by loop-mediated isothermal amplification.

    Science.gov (United States)

    Tao, Chenyu; Zhang, Qingde; Zhai, Shanli; Liu, Bang

    2013-11-01

    In this study, sensitive and rapid detection systems were designed using a loop-mediated isothermal amplification (LAMP) method to detect the genetically modified goats. A set of 4 primers were designed for each exogenous nucleic acids HBsAg and hATIII. The DNA samples were first amplified with the outer and inner primers and released a single-stranded DNA,of which both ends were stem-loop structure. Then one inner primer hybridized with the loop, and initiated displacement synthesis in less than 1 h. The result could be visualized by both agarose gel electrophoresis and unaided eyes directly after adding SYBR GREEN 1. The detection limit of LAMP was ten copies of target molecules, indicating that LAMP was tenfold more sensitive than the classical PCR. Furthermore, all the samples of genetically modified goats were tested positively by LAMP, and the results demonstrated that the LAMP was a rapid and sensitive method for detecting the genetically modified organism.

  5.   Indirect versus direct feedback in computer-based Prism Adaptation Therapy

    DEFF Research Database (Denmark)

    Wilms, Inge Linda; Rytter, Hana Malá

    2010-01-01

      Prism Adaptation Therapy (PAT) is an intervention method in the treatment of the attention disorder neglect (Frassinetti, Angeli, Meneghello, Avanzi, & Ladavas, 2002; Rossetti, et al., 1998). The aim of this study was to investigate whether one session of PAT using a computer-attached touchscreen...... have direct implications for future implementations of computer-based methods of treatment of visuospatial disorders and computer-assisted rehabilitation in general....

  6. THE PRISM MULTI-OBJECT SURVEY (PRIMUS). II. DATA REDUCTION AND REDSHIFT FITTING

    Energy Technology Data Exchange (ETDEWEB)

    Cool, Richard J. [MMT Observatory, Tucson, AZ 85721 (United States); Moustakas, John [Department of Physics, Siena College, 515 Loudon Rd., Loudonville, NY 12211 (United States); Blanton, Michael R.; Hogg, David W. [Center for Cosmology and Particle Physics, Department of Physics, New York University, 4 Washington Place, New York, NY 10003 (United States); Burles, Scott M. [D.E. Shaw and Co. L.P, 20400 Stevens Creek Blvd., Suite 850, Cupertino, CA 95014 (United States); Coil, Alison L.; Aird, James; Mendez, Alexander J. [Department of Physics, Center for Astrophysics and Space Sciences, University of California, 9500 Gilman Dr., La Jolla, San Diego, CA 92093 (United States); Eisenstein, Daniel J. [Harvard-Smithsonian Center for Astrophysics, 60 Garden St, MS 20, Cambridge, MA 02138 (United States); Wong, Kenneth C. [Steward Observatory, The University of Arizona, 933 N. Cherry Ave., Tucson, AZ 85721 (United States); Zhu, Guangtun [Center for Astrophysical Sciences, Department of Physics and Astronomy, Johns Hopkins University, 3400 North Charles Street, Baltimore, MD 21218 (United States); Bernstein, Rebecca A. [Department of Astronomy and Astrophysics, UCA/Lick Observatory, University of California, 1156 High Street, Santa Cruz, CA 95064 (United States); Bolton, Adam S. [Department of Physics and Astronomy, University of Utah, Salt Lake City, UT 84112 (United States)

    2013-04-20

    The PRIsm MUlti-object Survey (PRIMUS) is a spectroscopic galaxy redshift survey to z {approx} 1 completed with a low-dispersion prism and slitmasks allowing for simultaneous observations of {approx}2500 objects over 0.18 deg{sup 2}. The final PRIMUS catalog includes {approx}130,000 robust redshifts over 9.1 deg{sup 2}. In this paper, we summarize the PRIMUS observational strategy and present the data reduction details used to measure redshifts, redshift precision, and survey completeness. The survey motivation, observational techniques, fields, target selection, slitmask design, and observations are presented in Coil et al. Comparisons to existing higher-resolution spectroscopic measurements show a typical precision of {sigma}{sub z}/(1 + z) = 0.005. PRIMUS, both in area and number of redshifts, is the largest faint galaxy redshift survey completed to date and is allowing for precise measurements of the relationship between active galactic nuclei and their hosts, the effects of environment on galaxy evolution, and the build up of galactic systems over the latter half of cosmic history.

  7. Family Perspectives: Using a Cultural Prism to Understand Families from Asian Cultural Backgrounds

    Science.gov (United States)

    Lee, Suk-Hyang; Turnbull, Ann P.; Zan, Fei

    2009-01-01

    Educators can better serve students who come from diverse cultural backgrounds by understanding the differing cultural values of these students and their families. This article explores different cultural perspectives using a cultural prism approach, focused most specifically on the Korean and Chinese cultures. (Contains 2 tables.)

  8. Brain Activity Stimulated by Prism Adaptation Tasks Utilized for the Treatment of Unilateral Spatial Neglect: A Study with fNIRS

    Directory of Open Access Journals (Sweden)

    Hiroshi Taniguchi

    2012-01-01

    Full Text Available We investigated the neurological basis for efficacy of prism adaptation therapy, which is used for the treatment of poststroke unilateral spatial neglect (USN. Study subjects were 6 USN-positive (+, 6 USN-negative patients, and 6 healthy volunteer control subjects. USN was identified by the Behavioural Inattention Test (BIT. During the tasks, brain activity was assessed with fNIRS via changes in oxyHb concentration per unit length. There was no significant difference in the number of errors in the task between the 3 groups. However, in the USN(+ group there was a significantly greater reduction in oxyHb levels in the right parietal association cortex during the prism adaptation task than in the other 2 groups (<0.05. There was an immediate improvement in USN symptoms as well as a significant increase in oxyHb levels during the prism adaptation in the channels covering the right frontal and parietal lobes in 2 patients in the USN(+ group (<0.05. This result suggested that decreased activity in the right parietal association cortex, which is related to spatial perception, during the prism adaptation task and task-induced reorganization of the right frontal and parietal areas were involved in improvement in USN symptoms.

  9. Facile synthesis and photoluminescence spectroscopy of 3D-triangular GaN nano prism islands.

    Science.gov (United States)

    Kumar, Mukesh; Pasha, S K; Shibin Krishna, T C; Singh, Avanish Pratap; Kumar, Pawan; Gupta, Bipin Kumar; Gupta, Govind

    2014-08-21

    We report a strategy for fabrication of 3D triangular GaN nano prism islands (TGNPI) grown on Ga/Si(553) substrate at low temperature by N2(+) ions implantation using a sputtering gun technique. The annealing of Ga/Si(553) (600 °C) followed by nitridation (2 keV) shows the formation of high quality GaN TGNPI cross-section. TGNPI morphology has been confirmed by atomic force microscopy. Furthermore, these nano prism islands exhibit prominent ultra-violet luminescence peaking at 366 nm upon 325 nm excitation wavelength along with a low intensity yellow luminescence broad peak at 545 nm which characterizes low defects density TGNPI. Furthermore, the time-resolved spectroscopy of luminescent TGNPI in nanoseconds holds promise for its futuristic application in next generation UV-based sensors as well as many portable optoelectronic devices.

  10. Using the accelerated Brazilian concrete prism test (ABCPT to evaluate alkali aggregate reaction (AAR

    Directory of Open Access Journals (Sweden)

    L. Sanchez

    Full Text Available There are many test methods used in the laboratory to detect potential alkali-aggregate reactions (AAR. However, up to now, there is no consensus if they are reliable and efficient. This work presents the development of a new and accelerated concrete prism test called ABCPT (accelerate Brazilian concrete prism test as an attempt to create a reliable and fast test that can analyze and classify the potential reactivity of aggregates in the laboratory. For this research, six aggregates from different lithotypes were used. The methods CPT, ACPT and ABCPT were carried out with all the aggregates and a comparative analysis among all tests was performed. ABCPT seems to have a great potential to analyze and classify aggregates in the laboratory, although it needs further testing with other lithotypes to be confirmed as feasible.

  11. The demagnetizing field of a non-uniform rectangular prism

    DEFF Research Database (Denmark)

    Smith, Anders; Nielsen, Kaspar Kirstein; Christensen, Dennis

    2010-01-01

    The effect of demagnetization on the magnetic properties of a rectangular ferromagnetic prism under non-uniform conditions is investigated. A numerical model for solving the spatially varying internal magnetic field is developed, validated and applied to relevant cases. The demagnetizing field...... is solved by an analytical calculation and the coupling between applied field, the demagnetization tensor field and spatially varying temperature is solved through iteration. We show that the demagnetizing field is of great importance in many cases and that it is necessary to take into account the non...

  12. Design of a fast runback feature for PRISM control

    International Nuclear Information System (INIS)

    Wagner, W.K.; Rhow, S.K.; Daniel, W.R.; Dayal, Y.; Gaubatz, D.C.

    1988-01-01

    The nine power reactor inherently safe modules (PRISM) are controlled and their operation coordinated by a hierarchical, distributed, digital plant control system (PCS). This paper describes the fast runback features of the PCS. Fast runback consists of PCS directed reactor module shutdown with accompanying reductions of coolant flows. Analyses have shown that the PCS fast runback adequately terminates duty cycle events initiated in the balance of plant and the steam generating system, results in lower thermal shock to the reactor than scram, and reduces the number of scrams by approximately a factor of five

  13. Analysis of transverse field distributions in Porro prism resonators

    CSIR Research Space (South Africa)

    Litvin, IA

    2007-01-01

    Full Text Available in 1962 by Gould et al1 as a means to overcome misalignment problems in optical resonators employing Fabry-Perot cavities, by replacing the end face mirrors with crossed roof prisms. Lasers based on this principle have been developed over the years2... Optronics for the use of their laser and for making experimental data available to us. We would also like to thank Dr Dieter Preussler and Mr Daniel Esser for useful discussions. REFERENCES 1. G. Gould, S. Jacobs, P. Rabinowitz and T. Shultz...

  14. Intravesicular Phosphatase PHOSPHO1 Function in Enamel Mineralization and Prism Formation

    Directory of Open Access Journals (Sweden)

    Mirali Pandya

    2017-10-01

    Full Text Available The transport of mineral ions from the enamel organ-associated blood vessels to the developing enamel crystals involves complex cargo packaging and carriage mechanisms across several cell layers, including the ameloblast layer and the stratum intermedium. Previous studies have established PHOSPHO1 as a matrix vesicle membrane-associated phosphatase that interacts with matrix vesicles molecules phosphoethanolamine and phosphocholine to initiate apatite crystal formation inside of matrix vesicles in bone. In the present study, we sought to determine the function of Phospho1 during amelogenesis. PHOSPHO1 protein localization during amelogenesis was verified using immunohistochemistry, with positive signals in the enamel layer, ameloblast Tomes' processes, and in the walls of ameloblast secretory vesicles. These ameloblast secretory vesicle walls were also labeled for amelogenin and the exosomal protein marker HSP70 using immunohistochemistry. Furthermore, PHOSPHO1 presence in the enamel organ was confirmed by Western blot. Phospho1−/− mice lacked sharp incisal tips, featured a significant 25% increase in total enamel volume, and demonstrated a significant 2-fold reduction in silver grain density of von Kossa stained ground sections indicative of reduced mineralization in the enamel layer when compared to wild-type mice (p < 0.001. Scanning electron micrographs of Phospho1−/− mouse enamel revealed a loss of the prominent enamel prism “picket fence” structure, a loss of parallel crystal organization within prisms, and a 1.56-fold increase in enamel prism width (p < 0.0001. Finally, EDS elemental analysis demonstrated a significant decrease in phosphate incorporation in the enamel layer when compared to controls (p < 0.05. Together, these data establish that the matrix vesicle membrane-associated phosphatase PHOSPHO1 is essential for physiological enamel mineralization. Our findings also suggest that intracellular ameloblast secretory

  15. The PRISM concept

    International Nuclear Information System (INIS)

    Circeo, L.J. Jr.; Camacho, S.L.; Tixier, J.S.

    1994-01-01

    Contaminated soils and buried wastes represent one of the most widespread and costly remediation problems in the United States and other developed countries around the world. This concept of in situ remediation using a plasma arc torch should be directly applicable to many of the contaminated soil remediation needs described the DOE, EPA, and DoD. Plasma Remediation of In Situ Materials (PRISM) could provide a highly efficient, cost-effective, reliable and controllable technique to selectively melt and vitrify any contaminated/buried volume of soils, materials, or objects at any depth underground. If necessary, it could pinpoint underground objects such as buried drums for selective remediation. Plasma arc technology was developed over 30 years ago by NASA for the US space program to simulate reentry temperatures on heat shields. Only recently has this technology begun to emerge as a commercial tool in several industries such as steelmaking, metallurgy, precious metal recovery, and waste disposal. Conceptually, a plasma torch could be used on the ground surface or lowered to the bottom of a small diameter, cased borehole. By raising and operating the torch at progressively higher levels a column of contaminated material would be vitrified and converted into an environmentally safe, glassy residue, highly resistant to leaching. With proper borehole spacing the vitrified columns could be coalesced together to form a contiguous, homogeneous mass of vitrified material which is environmentally safe and highly resistant to leaching

  16. Prism therapy and visual rehabilitation in homonymous visual field loss.

    LENUS (Irish Health Repository)

    O'Neill, Evelyn C

    2011-02-01

    Homonymous visual field defects (HVFD) are common and frequently occur after cerebrovascular accidents. They significantly impair visual function and cause disability particularly with regard to visual exploration. The purpose of this study was to assess a novel interventional treatment of monocular prism therapy on visual functioning in patients with HVFD of varied etiology using vision targeted, health-related quality of life (QOL) questionnaires. Our secondary aim was to confirm monocular and binocular visual field expansion pre- and posttreatment.

  17. The PRISM reactor as a possible option to deal with the british civilian plutonium stockpile

    Energy Technology Data Exchange (ETDEWEB)

    Fichtlscherer, Christopher [IANUS, TU Darmstadt (Germany); Friess, Friederike [IANUS, TU Darmstadt (Germany); ISR, Universitaet fuer Bodenkultur Wien (Boku) (Austria)

    2017-07-01

    Dealing with stocks of separated weapon-usable plutonium is a big challenge for our modern society. This work focuses on the British civil plutonium stockpiles, which amount to 103.3 tons. One option is seen in irradiating the plutonium in a fast reactor under development, namely the GE PRISM reactor. The PRISM reactor is a small modular, fast reactor which has a thermal power of 840 MW and an electrical output of 311 MW. It is intended to use MOX fuel and proponents claim, that it thus would be possible to produce clean energy, while making the plutonium proliferation resistant. A MCNP model of the reactor is built and depletion calculations with different target burnups of the fuel were conducted to check whether the burned material would fulfil the Spent-Fuel Standard. Particularly it was checked whether the spent fuel is self protecting, meaning that the dose rate does not fall below a limit of 1 Sv/h in 1 meter distance after a cooling period of 30 years. Based on the reactor model calculations the irradiation time to fulfill this limit for the spent fuel is calculated. Based on the needed target burnup, it can be verified, whether it is possible for the PRISM reactor to render the civil plutonium proliferation resistant in only 20 years as is is claimed by its proponents.

  18. Fluid expulsion sites on the Cascadia accretionary prism: mapping diagenetic deposits with processed GLORIA imagery

    Science.gov (United States)

    Carson, Bobb; Seke, Erol; Paskevich, Valerie F.; Holmes, Mark L.

    1994-01-01

    Point-discharge fluid expulsion on accretionary prisms is commonly indicated by diagenetic deposition of calcium carbonate cements and gas hydrates in near-surface (topographic and lithologic information. We have processed GLORIA imagery from the Oregon continental margin to remove topographic effects. A synthetic side scan image was created initially from Sea Beam bathymetric data and then was subtracted iteratively from the original GLORIA data until topographic features disappeared. The residual image contains high-amplitude backscattering that we attribute to diagenetic deposits associated with fluid discharge, based on submersible mapping, Ocean Drilling Program drilling, and collected samples. Diagenetic deposits are concentrated (1) near an out-of-sequence thrust fault on the second ridge landward of the base of the continental slope, (2) along zones characterized by deep-seated strikeslip faults that cut transversely across the margin, and (3) in undeformed Cascadia Basin deposits which overlie incipient thrust faults seaward of the toe of the prism. There is no evidence of diagenetic deposition associated with the frontal thrust that rises from the dècollement. If the dècollement is an important aquifer, apparently the fluids are passed either to the strike-slip faults which intersect the dècollement or to the incipient faults in Cascadia Basin for expulsion. Diagenetic deposits seaward of the prism toe probably consist dominantly of gas hydrates.

  19. Thermal stresses in long prisms by relaxation methods

    International Nuclear Information System (INIS)

    Cummins, J.D.

    1959-07-01

    A general method is presented for calculating the elastic thermal stresses in long prisms which are producing heat and are not solvable by simple analytical methods. The problem of an inverted lattice i.e. an hexagonal coolant passage surrounded by hexagonal fuel elements is considered and the temperature and principal thermal stress distributions evaluated for the particular case of 20% coolant. The maximum thermal stress for this type of fuel element is about the same as the maximum thermal stress in a cylindrical fuel element surrounded by a sea of coolant assuming the existence of the same maximum temperature drop and material properties. (author)

  20. Thermal stresses in long prisms by relaxation methods

    Energy Technology Data Exchange (ETDEWEB)

    Cummins, J D [Atomic Energy Establishment, Winfrith, Dorchester, Dorset (United Kingdom)

    1959-07-15

    A general method is presented for calculating the elastic thermal stresses in long prisms which are producing heat and are not solvable by simple analytical methods. The problem of an inverted lattice i.e. an hexagonal coolant passage surrounded by hexagonal fuel elements is considered and the temperature and principal thermal stress distributions evaluated for the particular case of 20% coolant. The maximum thermal stress for this type of fuel element is about the same as the maximum thermal stress in a cylindrical fuel element surrounded by a sea of coolant assuming the existence of the same maximum temperature drop and material properties. (author)

  1. Evaluation of the microparticle enzyme immunoassay Abbott IMx Select Chlamydia and the importance of urethral site sampling to detect Chlamydia trachomatis in women.

    OpenAIRE

    Brokenshire, M K; Say, P J; van Vonno, A H; Wong, C

    1997-01-01

    OBJECTIVE: To evaluate the commercial microparticle enzyme immunoassay (MEIA), Abbott IMx Select Chlamydia, for the detection of Chlamydia trachomatis in women and to compare its performance with endocervical cell culture. Also, to determine whether sampling the urethral site is an important part of chlamydial diagnosis in women. SETTING: The Auckland, Manukau, and Waitakere Sexual Health Clinics, Auckland, New Zealand and the Department of Clinical Microbiology, Auckland Hospital, Auckland, ...

  2. Basal and prism dislocation cores in magnesium: comparison of first-principles and embedded-atom-potential methods predictions

    International Nuclear Information System (INIS)

    Yasi, J A; Nogaret, T; Curtin, W A; Trinkle, D R; Qi, Y; Hector, L G Jr

    2009-01-01

    The core structures of screw and edge dislocations on the basal and prism planes in Mg, and the associated gamma surfaces, were studied using an ab initio method and the embedded-atom-method interatomic potentials developed by Sun et al and Liu et al. The ab initio calculations predict that the basal plane dislocations dissociate into partials split by 16.7 Å (edge) and 6.3 Å (screw), as compared with 14.3 Å and 12.7 Å (Sun and Liu edge), and 6.3 Å and 1.4 Å (Sun and Liu screw), with the Liu screw dislocation being metastable. In the prism plane, the screw and edge cores are compact and the edge core structures are all similar, while ab initio does not predict a stable prismatic screw in stress-free conditions. These results are qualitatively understood through an examination of the gamma surfaces for interplanar sliding on the basal and prism planes. The Peierls stresses at T = 0 K for basal slip are a few megapascals for the Sun potential, in agreement with experiments, but are ten times larger for the Liu potential. The Peierls stresses for prism slip are 10–40 MPa for both potentials. Overall, the dislocation core structures from ab initio are well represented by the Sun potential in all cases while the Liu potential shows some notable differences. These results suggest that the Sun potential is preferable for studying other dislocations in Mg, particularly the (c + a) dislocations, for which the core structures are much larger and not accessible by ab initio methods

  3. The PRISM (Pliocene Palaeoclimate) reconstruction: Time for a paradigm shift

    Science.gov (United States)

    Dowsett, Harry J.; Robinson, Marci M.; Stoll, Danielle K.; Foley, Kevin M.; Johnson, Andrew L. A.; Williams, Mark; Riesselman, Christina

    2013-01-01

    Global palaeoclimate reconstructions have been invaluable to our understanding of the causes and effects of climate change, but single-temperature representations of the oceanic mixed layer for data–model comparisons are outdated, and the time for a paradigm shift in marine palaeoclimate reconstruction is overdue. The new paradigm in marine palaeoclimate reconstruction stems the loss of valuable climate information and instead presents a holistic and nuanced interpretation of multi-dimensional oceanographic processes and responses. A wealth of environmental information is hidden within the US Geological Survey's Pliocene Research,Interpretation and Synoptic Mapping (PRISM) marine palaeoclimate reconstruction, and we introduce here a plan to incorporate all valuable climate data into the next generation of PRISM products. Beyond the global approach and focus, we plan to incorporate regional climate dynamics with emphasis on processes, integrating multiple environmental proxies wherever available in order to better characterize the mixed layer, and developing a finer time slice within the Mid-Piacenzian Age of the Pliocene, complemented by underused proxies that offer snapshots into environmental conditions. The result will be a proxy-rich, temporally nested, process-oriented approach in a digital format - a relational database with geographic information system capabilities comprising a three-dimensional grid representing the surface layer, with a plethora of data in each cell.

  4. PENGUKURAN KINERJA UMKM MENGGUNAKAN PERFORMANCE PRISM

    Directory of Open Access Journals (Sweden)

    Cynthia Agelina Purnomo

    2017-10-01

    Full Text Available UMKM XYZ merupakan perusahaan yang bergerak di bidang pengolahan keripik buah nangka. Pada proses observasi langsung di lapangan, perusahaan mempunyai masalah dalam melakukan pengukuran kinerja. Pengukuran kinerja yang dilakukan hanya berdasarkan Net Profit Margin (rasio laba bersih dibandingkan dengan pendapatan tiap tahunnya. Pengukuran yang dilakukan oleh perusahaan tidak cukup representatif menilai kinerja perusahaan secara keseluruhan. Oleh karena itu, diperlukan alat ukur kinerja yang tepat dan fleksibel, yaitu dengan metode Performance Prism. Proses penentuan Key Performance Indicator (KPI kinerja berdasarkan persetujuan dari pihak manajer perusahaan. Dengan periode dasar (tahun 2015 didapatkan hasil bahwa terdapat 25 Key Performance Indicator yang terdiri dari: 2 KPI Investor, 8 KPI Konsumen, 4 KPI Suplier, 6 KPI Karyawan, dan 5 KPI Masyarakat Sekitar dengan nilai total kinerja keseluruhan sebagai pembanding dengan periode pengukuran adalah 2,232 (kategori cukup sehingga perlu ditingkatkan lagi pada periode selanjutnya berdasarkan saran-saran pada periode dasar.

  5. The StreamCat Dataset: Accumulated Attributes for NHDPlusV2 Catchments (Version 2.1) for the Conterminous United States: PRISM

    Science.gov (United States)

    This dataset represents climate observations throughout the years 2008-09 within individual local NHDPlusV2 catchments and upstream, contributing watersheds based on the Composite Topographic Index (See Supplementary Info for Glossary of Terms). PRISM is a set of monthly, yearly, and single-event gridded data products of mean temperature and precipitation, max/min temperatures, and dewpoints, primarily for the United States. In-situ point measurements are ingested into the PRISM (Parameter elevation Regression on Independent Slopes Model) statistical mapping system. The PRISM products use a weighted regression scheme to account for complex climate regimes associated with orography, rain shadows, temperature inversions, slope aspect, coastal proximity, and other factors. (see Data Sources for links to NHDPlusV2 data and USGS Data) These data were summarized to produce local catchment-level and watershed-level metrics as a continuous data type (see Data Structure and Attribute Information for a description).

  6. Broadband IR polarizing beam splitter using a subwavelength-structured one-dimensional photonic-crystal layer embedded in a high-index prism.

    Science.gov (United States)

    Khanfar, H K; Azzam, R M A

    2009-09-20

    An iterative procedure for the design of a polarizing beam splitter (PBS) that uses a form-birefringent, subwavelength-structured, one-dimensional photonic-crystal layer (SWS 1-D PCL) embedded in a high-index cubical prism is presented. The PBS is based on index matching and total transmission for the p polarization and total internal reflection for the s polarization at the prism-PCL interface at 45 degrees angle of incidence. A high extinction ratio in reflection (>50 dB) over the 4-12 microm IR spectral range is achieved using a SWS 1-D PCL of ZnTe embedded in a ZnS cube within an external field of view of +/-6.6 degrees and in the presence of grating filling factor errors of up to +/-10%. Comparable results, but with wider field of view, are also obtained with a Ge PCL embedded in a Si prism.

  7. PERANCANGAN SISTEM PENGUKURAN KINERJA DENGAN METODE PERFORMANCE PRISM (Studi Kasus di Plaza Hotel Semarang

    Directory of Open Access Journals (Sweden)

    Hery Suliantoro

    2012-03-01

    Full Text Available Selama ini Plaza hotel belum pernah melakukan pengukuran kinerja yang terintegrasi yang terdiri dari aspek finansial dan non finansial. Dilihat dari prosentase tingkat hunian yang tidak memenuhi target yang ditetapkan, maka pengukuran kinerja yang terintegrasi diharapkan mampu memberikan perbaikan kinerja yang diharapkan. Dengan menggunakan performance prism, dilakukan identifikasi kebutuhan dan kontribusi stakeholder secara keseluruhan sehingga didapat indikator kinerja dari kriteria strategi, proses dan kapabilitas yang dijadikan tolok ukur perbaikan kinerja.. tahap pengumpulan data dengan menyebarkan matriks perbandingan berpasangan sebagai dasar penyusunan bobot kepentingan pada AHP dan kuesioner target pencapaian kinerja sebagai dasar penetapan skor aktual pada OMAX. Dari analisis yang dilakukan setelah bobot kepentingan diperoleh dan perhitungan nilai performansi, dilakukan simulasi perbaikan satu-satuan nilai performansi agar didapat kriteria dan elemen apa saja yang mendapat prioritas perbaikan dan rekomendasi perbaikan yang perlu dilakukan untuk meningkatkan kinerja Plaza Hotel Semarang. Kata kunci : Performance Prism, AHP, OMAX, skor aktual

  8. Moving forward with prisms: Sensory-motor adaptation improves gait initiation in Parkinson’s disease.

    Directory of Open Access Journals (Sweden)

    Janet Helen Bultitude

    2012-09-01

    Full Text Available It is postulated that the decreased walking speed; small, shuffling steps; and ‘freezing’ shown by patients with Parkinson’s disease could stem from an inability to tilt the body forward enough to provide sufficient forward propulsion. In two repeated-measures studies we examined whether adaptation to upward-shifting prisms, resulting in a downward after-effect, could improve gait initiation in healthy participants and patients with Parkinson’s disease. Faster forward stepping followed a brief (5 min exposure period for patients, and a longer (20 min exposure period for age-matched controls. Backward stepping was unchanged, and adaptation to downward-shifting prisms with control participants showed no effect on forward or backward stepping. These results suggest that adaptation of arm proprioception in the vertical plane may generalise to anterior-posterior postural control, presenting new possibilities for the treatment of gait disturbance in basal ganglia disorders.

  9. The Refractive Index Measurement Of Silicon Dioxide Thin Film by the Coupling Prism Method

    International Nuclear Information System (INIS)

    Budianto, Anwar; Hariyanto, Sigit; Subarkah

    1996-01-01

    Refractive index of silicon dioxide thin film that doped with phosphor (SiO 2 :P) above the pure silicon dioxide substrate has been measured by light coupling prism method. The method principle is focusing the light on coupling prism base so that the light propagates into the waveguide layer while the reflected one forms a mode in the observation plane. The SiO 2 thin film as waveguide layer has a refractive index that give the thick and refractive index relation. The He-Ne laser as light source has the wavelength λ 0,6328 μm. The refractive index measurement of the thin film with the substrate refractive index n sb = 1,47 and the thin film thick d = 2μm gives n g = 1,5534 ± 0,01136. This method can distinguish the refractive index of thin film about 6% to the refractive index of substrate

  10. Comparison of the Abbott RealTime CT new formulation assay with two other commercial assays for detection of wild-type and new variant strains of Chlamydia trachomatis

    DEFF Research Database (Denmark)

    Møller, Jens Kjølseth; Pedersen, Lisbeth Nørum; Persson, Kenneth

    2010-01-01

    In an analytical methods comparison study on clinical samples, the Abbott RealTime CT new formulation assay (m2000 real-time PCR) consisting of a duplex PCR targeting different parts of the cryptic plasmid in Chlamydia trachomatis was compared with version 2 of the Roche COBAS(R) TaqMan(R) CT ass...

  11. Experimental Evaluation of Lightweight AAC Masonry Wall Prisms with Ferrocement Layers in Compression and Flexure

    KAUST Repository

    Abdel Mooty, Mohamed; Hendam, Ahmed; Fahmy, Ezzat; Abou Zeid, Mohamed; Haroun, Medhat

    2012-01-01

    An experimental program is designed to evaluate the performance of lightweight autoclaved aerated concrete masonry wall strengthened using ferrocement layers, in a sandwich structure, under in-plane compression and out-of-plane bending. The 25 mm thick ferrocement mortar is reinforced with steel welded wire mesh of 1 mm diameters at 15 mm spacing. Different types of shear connectors are used to evaluate their effect on failure loads. The effect of different design parameters on the wall strength are considered including wall thickness, mortar strength, and type and distribution of shear connectors. A total of 20 prisms are tested in compression and 5 prisms are tested under bending. The proposed ferrocement strengthening technique is easy to apply on existing wall system and results in significant strength and stiffness enhancement of the tested wall specimens. © (2012) Trans Tech Publications.

  12. Experimental Evaluation of Lightweight AAC Masonry Wall Prisms with Ferrocement Layers in Compression and Flexure

    KAUST Repository

    Abdel Mooty, Mohamed

    2012-05-01

    An experimental program is designed to evaluate the performance of lightweight autoclaved aerated concrete masonry wall strengthened using ferrocement layers, in a sandwich structure, under in-plane compression and out-of-plane bending. The 25 mm thick ferrocement mortar is reinforced with steel welded wire mesh of 1 mm diameters at 15 mm spacing. Different types of shear connectors are used to evaluate their effect on failure loads. The effect of different design parameters on the wall strength are considered including wall thickness, mortar strength, and type and distribution of shear connectors. A total of 20 prisms are tested in compression and 5 prisms are tested under bending. The proposed ferrocement strengthening technique is easy to apply on existing wall system and results in significant strength and stiffness enhancement of the tested wall specimens. © (2012) Trans Tech Publications.

  13. Designing and researching of the virtual display system based on the prism elements

    Science.gov (United States)

    Vasilev, V. N.; Grimm, V. A.; Romanova, G. E.; Smirnov, S. A.; Bakholdin, A. V.; Grishina, N. Y.

    2014-05-01

    Problems of designing of systems for virtual display systems for augmented reality placed near the observers eye (so called head worn displays) with the light guide prismatic elements are considered. Systems of augmented reality is the complex consists of the image generator (most often it's the microdisplay with the illumination system if the display is not self-luminous), the objective which forms the display image practically in infinity and the combiner which organizes the light splitting so that an observer could see the information of the microdisplay and the surrounding environment as the background at the same time. This work deals with the system with the combiner based on the composite structure of the prism elements. In the work three cases of the prism combiner design are considered and also the results of the modeling with the optical design software are presented. In the model the question of the large pupil zone was analyzed and also the discontinuous character (mosaic structure) of the angular field in transmission of the information from the microdisplay to the observer's eye with the prismatic structure are discussed.

  14. The Clinical Utility of ASRS-v1.1 for Identifying ADHD in Alcoholics Using PRISM as the Reference Standard.

    Science.gov (United States)

    Reyes, Maria M; Schneekloth, Terry D; Hitschfeld, Mario J; Geske, Jennifer R; Atkinson, David L; Karpyak, Victor M

    2016-05-02

    The objective was to assess the clinical utility of the Adult ADHD Self-Report Scale (ASRS-v1.1) in identifying ADHD in alcoholics using the Psychiatric Research Interview for Substance and Mental Disorders (PRISM) as the diagnostic "gold standard." We performed a secondary analysis of data from 379 treatment-seeking alcoholics who completed the ASRS-v1.1 and the ADHD module of the PRISM. Data analysis included descriptive statistics. The prevalence of ADHD was 7.7% (95% CI = [5.4, 10.8]). The positive predictive value (PPV) of the ASRS-v1.1 was 18.1% (95% CI = [12.4, 25.7]) and the negative predictive value (NPV) was 97.6% (95% CI = [94.9, 98.9]). The ASRS-v1.1 demonstrated a sensitivity of 79.3% (95% CI = [61.6, 90.2]) and a specificity of 70.3% (95% CI = [65.3, 74.8]). The ASRS-v1.1 demonstrated acceptable sensitivity and specificity in a sample of treatment-seeking alcoholics when compared with the PRISM as the reference standard for ADHD diagnosis. © The Author(s) 2016.

  15. Analytical and Clinical Performance Evaluation of the Abbott Architect PIVKA Assay.

    Science.gov (United States)

    Ko, Dae-Hyun; Hyun, Jungwon; Kim, Hyun Soo; Park, Min-Jeong; Kim, Jae-Seok; Park, Ji-Young; Shin, Dong Hoon; Cho, Hyoun Chan

    2018-01-01

    Protein induced by vitamin K absence (PIVKA) is measured using various assays and is used to help diagnose hepatocellular carcinoma. The present study evaluated the analytical and clinical performances of the recently released Abbott Architect PIVKA assay. Precision, linearity, and correlation tests were performed in accordance with the Clinical Laboratory Standardization Institute guidelines. Sample type suitability was assessed using serum and plasma samples from the same patients, and the reference interval was established using sera from 204 healthy individuals. The assay had coefficients of variation of 3.2-3.5% and intra-laboratory variation of 3.6-5.5%. Linearity was confirmed across the entire measurable range. The Architect PIVKA assay was comparable to the Lumipulse PIVKA assay, and the plasma and serum samples provided similar results. The lower reference limit was 13.0 mAU/mL and the upper reference limit was 37.4 mAU/mL. The ability of the Architect PIVKA assay to detect hepatocellular carcinoma was comparable to that of the alpha-fetoprotein test and the Lumipulse PIVKA assay. The Architect PIVKA assay provides excellent analytical and clinical performance, is simple for clinical laboratories to adopt, and has improved sample type suitability that could broaden the assay's utility. © 2018 by the Association of Clinical Scientists, Inc.

  16. Field evaluation of an open and polyvalent universal HIV-1/SIVcpz/SIVgor quantitative RT-PCR assay for HIV-1 viral load monitoring in comparison to Abbott RealTime HIV-1 in Cameroon.

    Science.gov (United States)

    Guichet, Emilande; Aghokeng, Avelin; Eymard-Duvernay, Sabrina; Vidal, Nicole; Ayouba, Ahidjo; Mpoudi Ngole, Eitel; Delaporte, Eric; Ciaffi, Laura; Peeters, Martine

    2016-11-01

    With the increasing demand of HIV viral load (VL) tests in resource-limited countries (RLCs) there is a need for assays at affordable cost and able to quantify all known HIV-1 variants. VLs obtained with a recently developed open and polyvalent universal HIV-1/SIVcpz/SIVgor RT-qPCR were compared to Abbott RealTime HIV-1 assay in Cameroon. On 474 plasma samples, characterized by a wide range of VLs and a broad HIV-1 group M genetic diversity, 97.5% concordance was observed when using the lower detection limit of each assay. When using the threshold of 3.00 log 10 copies/mL, according to WHO guidelines to define virological failure (VF) in RLCs, the concordance was 94.7%, 360/474 versus 339/474 patients were identified with VF with the new assay and Abbott RealTime HIV-1, respectively. Higher VLs were measured with the new assay, +0.47 log 10 copies/mL (95% CI; 0.42-0.52) as shown with Bland-Altman analysis. Eleven samples from patients on VF with drug resistance were not detected by Abbott RealTime HIV-1 versus two only with the new assay. Overall, our study showed that the new assay can be easily implemented in a laboratory in RLCs with VL experience and showed good performance on a wide diversity of HIV-1 group M variants. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. HEATING OF BLANK IN FORM OF PRISM IN ACCORDANCE WITH TECHNOLOGICAL LIMITATIONS

    Directory of Open Access Journals (Sweden)

    V. B. Kovalevsky

    2009-01-01

    Full Text Available The paper considers a problem on optimum heating control of a blank in the form of prism under complicated conditions of heat-transfer in accordance with criteria of gas consumption minimization, decarburized layer and scaling. Numerical algorithm of the problem solution and examples are given in the paper. A new technology of the flame furnace operation has been developed in the paper. 

  18. Results of the Abbott RealTime HIV-1 assay for specimens yielding "target not detected" results by the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test.

    Science.gov (United States)

    Babady, N Esther; Germer, Jeffrey J; Yao, Joseph D C

    2010-03-01

    No significantly discordant results were observed between the Abbott RealTime HIV-1 assay and the COBAS AmpliPrep/COBAS TaqMan HIV-1 Test (CTM) among 1,190 unique clinical plasma specimens obtained from laboratories located in 40 states representing all nine U.S. geographic regions and previously yielding "target not detected" results by CTM.

  19. The Roche Immunoturbidimetric Albumin Method on Cobas c 501 Gives Higher Values Than the Abbott and Roche BCP Methods When Analyzing Patient Plasma Samples.

    Science.gov (United States)

    Helmersson-Karlqvist, Johanna; Flodin, Mats; Havelka, Aleksandra Mandic; Xu, Xiao Yan; Larsson, Anders

    2016-09-01

    Serum/plasma albumin is an important and widely used laboratory marker and it is important that we measure albumin correctly without bias. We had indications that the immunoturbidimetric method on Cobas c 501 and the bromocresol purple (BCP) method on Architect 16000 differed, so we decided to study these methods more closely. A total of 1,951 patient requests with albumin measured with both the Architect BCP and Cobas immunoturbidimetric methods were extracted from the laboratory system. A comparison with fresh plasma samples was also performed that included immunoturbidimetric and BCP methods on Cobas c 501 and analysis of the international protein calibrator ERM-DA470k/IFCC. The median difference between the Abbott BCP and Roche immunoturbidimetric methods was 3.3 g/l and the Roche method overestimated ERM-DA470k/IFCC by 2.2 g/l. The Roche immunoturbidimetric method gave higher values than the Roche BCP method: y = 1.111x - 0.739, R² = 0.971. The Roche immunoturbidimetric albumin method gives clearly higher values than the Abbott and Roche BCP methods when analyzing fresh patient samples. The differences between the two methods were similar at normal and low albumin levels. © 2016 Wiley Periodicals, Inc.

  20. PRISM reactor system design and analysis of postulated unscrammed events

    International Nuclear Information System (INIS)

    Van Tuyle, G.J.; Slovik, G.C.

    1991-01-01

    Key safety characteristics of the PRISM reactor system include the passive reactor shutdown characteristic and the passive shutdown heat removal system, RVACS. While these characteristics are simple in principle, the physical processes are fairly complex, particularly for the passive reactor shutdown. It has been possible to adapt independent safety analysis codes originally developed for the Clinch River Breeder Reactor review, although some limitations remain. In this paper, the analyses of postulated unscrammed events are discussed, along with limitations in the predictive capabilities and plans to correct the limitations in the near future. (author)

  1. Distance 2-Domination in Prisms of Graphs

    Directory of Open Access Journals (Sweden)

    Hurtado Ferran

    2017-05-01

    Full Text Available A set of vertices D of a graph G is a distance 2-dominating set of G if the distance between each vertex u ∊ (V (G − D and D is at most two. Let γ2(G denote the size of a smallest distance 2-dominating set of G. For any permutation π of the vertex set of G, the prism of G with respect to π is the graph πG obtained from G and a copy G′ of G by joining u ∊ V(G with v′ ∊ V(G′ if and only if v′ = π(u. If γ2(πG = γ2(G for any permutation π of V(G, then G is called a universal γ2-fixer. In this work we characterize the cycles and paths that are universal γ2-fixers.

  2. Accelerated Determination of ASR Susceptibility during Concrete Prism Testing through Nonlinear Resonance Ultrasonic Spectroscopy : TechBrief

    Science.gov (United States)

    2013-10-01

    The research has been conducted on laboratory-cast concrete prism specimens containing both fine and coarse aggregates obtained from different sources to provide a spectrum of reactivity for assessment through the developed NIRAS technique. The NIRAS...

  3. A VUV prism spectrometer for RICH radiator refractometry

    CERN Document Server

    Moyssides, P G; Fokitis, E

    2000-01-01

    A prism spectrometer has been developed to operate in the VUV wavelength range from 120 to 200 nm. It can be used as a pre- disperser in conjunction with a Fabry-Perot based gas refractometer. This instrument has also been used to measure the refractive index of the liquid radiator C/sub 6/F/sub 14/ in various spectral lines. This radiator is used in the RICH detectors of the DELPHI experiment and has been proposed for ALICE, and LHCb experiments. The spectral resolution of the system is improved as the wavelength decreases and the data are consistent with a wavelength accuracy about 0.4 nm at 140 nm. The results for the dispersion curve of the above liquid are presented. (17 refs).

  4. The StreamCat Dataset: Accumulated Attributes for NHDPlusV2 Catchments (Version 2.1) for the Conterminous United States: PRISM Data

    Science.gov (United States)

    This dataset represents climate observations within individual, local NHDPlusV2 catchments and upstream, contributing watersheds. Attributes of the landscape layer were calculated for every local NHDPlusV2 catchment and accumulated to provide watershed-level metrics. (See Supplementary Info for Glossary of Terms) PRISM is a set of monthly, yearly, and single-event gridded data products of mean temperature and precipitation, max/min temperatures, and dewpoints, primarily for the United States. In-situ point measurements are ingested into the PRISM (Parameter elevation Regression on Independent Slopes Model) statistical mapping system. The PRISM products use a weighted regression scheme to account for complex climate regimes associated with orography, rain shadows, temperature inversions, slope aspect, coastal proximity, and other factors. (see Data Sources for links to NHDPlusV2 data and USGS Data) These data are summarized by local catchment and by watershed to produce local catchment-level and watershed-level metrics as a continuous data type (see Data Structure and Attribute Information for a description).

  5. Minimal residual HIV viremia: verification of the Abbott Real-Time HIV-1 assay sensitivity

    Directory of Open Access Journals (Sweden)

    Alessandra Amendola

    2010-06-01

    Full Text Available Introduction: In the HIV-1 infection, the increase in number of CD4 T lymphocytes and the viral load decline are the main indicators of the effectiveness of antiretroviral therapy. On average, 85% of patients receiving effective treatment has a persistent suppression of plasma viral load below the detection limit (<50 copies/mL of clinically used viral load assays, regardless of treatment regimen in use. It is known, however, that, even when viremia is reduced below the sensitivity limit of current diagnostic assays, the virus persists in “reservoirs” and traces of free virions can be detected in plasma.There is a considerable interest to investigate the clinical significance of residual viremia. Advances in molecular diagnostics allows nowadays to couple a wide dynamic range to a high sensitivity.The Abbott Real-time HIV-1 test is linear from 40 to 107 copies/mL and provides, below 40 copies/mL, additional information such as “<40cp/mL, target detected” or “target not detected”. The HIV-1 detection is verified by the max-Ratio algorithm software.We assessed the test sensitivity when the qualitative response is considered as well. Methods: A ‘probit’ analysis was performed using dilutions of the HIV-1 RNA Working Reagent 1 for NAT assays (NIBSC code: 99/634, defined in IU/mL and different from that used by the manufacturer (VQA,Virology Quality Assurance Laboratory of the AIDS Clinical Trial Group for standardization and definition of performances.The sample input volume (0.6 mL was the same used in clinical routine. A total of 196 replicates at concentrations decreasing from 120 to 5 copies/mL, in three different sessions, have been tested.The ‘probit’ analysis (binomial dose-response model, 95% “hit-rate” has been carried out on the SAS 9.1.3 software package. Results: The sensitivity of the “<40cp/mL, target detected” response was equal to 28,76 copies/mL, with 95% confidence limits between 22,19 and 52,27 copies

  6. Results of the Abbott RealTime HIV-1 Assay for Specimens Yielding “Target Not Detected” Results by the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test▿

    OpenAIRE

    Babady, N. Esther; Germer, Jeffrey J.; Yao, Joseph D. C.

    2009-01-01

    No significantly discordant results were observed between the Abbott RealTime HIV-1 assay and the COBAS AmpliPrep/COBAS TaqMan HIV-1 Test (CTM) among 1,190 unique clinical plasma specimens obtained from laboratories located in 40 states representing all nine U.S. geographic regions and previously yielding “target not detected” results by CTM.

  7. FDS5 Simulation for OECD PRISME Fire Test of DOOR PRSD5

    International Nuclear Information System (INIS)

    Lee, Kyu Bok; Park, Jong Seuk

    2009-01-01

    OECD/NEA PRISME Fire Project is an international co-operation project to investigate fire propagation by means of experiments and analyses for nuclear power plant applications. This project focuses on the generation of experimental data for fire and smoke propagation from the fire room to adjacent rooms under various conditions and room configurations. In addition, analyses using computer codes are performed to understand the phenomena of interest and to produce a consistent interpretation of the experimental results. The PRISME Project is composed of series of tests named as SOURCE, DOOR, LEAK and Global Tests. The SOURCE is composed of tests to characterize the fire source, and the DOOR is to study fire and smoke propagation through an open door, while the LEAK is to investigate hot gas leakages through other modes of openings such as holes, a slot, a duct, and a partially opened door. The Global test will be conducted as integral tests on the basis of the results of the previous separate effects tests. In this paper, simulations are performed with FDS5 computer code for the DOOR Test No.5 (PRS D 5) and the calculation results are compared with the corresponding experimental data to study the code capability to predict the phenomena of the hot gas propagation between two rooms

  8. On the geometrically nonlinear elastic response of class θ = 1 tensegrity prisms

    Science.gov (United States)

    Mascolo, Ida; Amendola, Ada; Zuccaro, Giulio; Feo, Luciano; Fraternali, Fernando

    2018-03-01

    The present work studies the geometrically nonlinear response of class ϑ=1 tensegrity prisms modeled as a collection of elastic springs reacting in tension (strings or cables) or compression (bars), under uniform uniaxial loading. The incremental equilibrium equations of the structure are numerically solved through a path-following procedure, with the aim of modeling the mechanical behavior of the structure in the large displacement regime. Several numerical results are presented with reference to a variety of physical models, which use two different materials for the cables and the bars, and show different aspect ratios associated with either 'standard' or 'expanded' configurations. An experimental validation of the predicted constitutive response is conducted with reference to a 'thick' and a 'slender' model, observing rather good theory vs. experiment matching. The given numerical and experimental results highlight that the elastic response of the examined structures may switch from stiffening to softening, depending on the geometry of the system, the magnitude of the external load, and the applied prestress. The outcomes of the current study confirm previous literature results on the elastic response of minimal tensegrity prisms, and pave the way to the use of tensegrity systems as nonlinear spring units forming tunable mechanical metamaterials.

  9. Contributions of Arctic PRISM to monitoring western hemispheric shorebirds

    Science.gov (United States)

    Skagen, Susan K.; Smith, Paul A.; Andres, Brad A.; Donaldson, Garry; Brown, Stephen

    2012-01-01

    for assessing its vulnerability and subsequent listing under the U.S. Endangered Species Act and the Canadian Species at Risk Act. To meet the need for information on population size and trends, shorebird biologists from Canada and the United States proposed a shared blueprint for shorebird monitoring across the Western Hemisphere in the late 1990s; this effort was undertaken in concert with the development of the Canadian and U.S. Shorebird Conservation Plans (Donaldson et al. 2000, Brown et aL 2001). Soon thereafter, partners in the monitoring effort adopted the name "Program for Regional and International Shorebird Monitoring" (PRISM). Among the primary objectives of PRISM were to estimate the population sizes and trends of breeding North American shorebirds and describe their distributions (Bart et al. 2002). PRISM members evaluated ongoing and potential monitoring approaches to address 74 taxa (including subspecies) and proposed a combination of arctic andboreal breeding surveys, temperate breeding and non-breeding surveys, and neotropical surveys.

  10. Graphite oxide-mediated synthesis of porous CeO2 quadrangular prisms and their high-efficiency adsorptive performance

    International Nuclear Information System (INIS)

    Chang, Ling; Wang, Fengxian; Xie, Dong; Zhang, Jun; Du, Gaohui

    2013-01-01

    Graphical abstract: - Highlights: • Porous CeO 2 quadrangular prisms have been prepared via graphite oxide-mediated synthesis. • Dual-pore hierarchical systems are formed with the pore distributions around 4 nm and 30 nm. • Porous CeO 2 exhibits a rapid adsorption to Rhodamine B with a removal efficiency of ∼99%. • Porous CeO 2 retains the same performances in different pH solutions. - Abstract: We report a graphite oxide-mediated approach for synthesizing porous CeO 2 through a facile hydrothermal process followed by thermal annealing in air. The phase structure, morphology, microstructure and porosity of the products have been revealed by a combination of X-ray diffraction, scanning electron microscopy, transmission electron microscopy, and N 2 adsorption. The as-prepared CeO 2 products show well-defined quadrangular prism morphology, and they are composed of interconnected nanoparticles with diameters around 30–100 nm. In particular, the dual-pore hierarchical systems are created in the CeO 2 quadrangular prisms with the pore distributions around 4 nm and 30 nm. The dye sorption capacity of the porous CeO 2 is investigated, which exhibits a rapid adsorption to rhodamine B with a high removal efficiency of ∼99%. Moreover, the CeO 2 absorbent retains the same performances in different pH solutions

  11. Post-cracking behavior of blocks, prisms, and small concrete walls reinforced with plant fiber

    Directory of Open Access Journals (Sweden)

    I. I. Soto

    Full Text Available Structural masonry using concrete blocks promotes the rationalization of construction projects, lowering the final cost of a building through the elimination of forms and the reduction of the consumption of reinforcement bars. Moreover, production of a block containing a combination of concrete and vegetable fiber sisal results in a unit with properties such as mechanical strength, stiffness, flexibility, ability to absorb energy, and post-cracking behavior that are comparable to those of a block produced with plain concrete. Herein are reported the results of a study on the post-cracking behavior of blocks, prisms, and small walls reinforced with sisal fibers (lengths of 20 mm and 40 mm added at volume fractions of 0.5% and 1%. Tests were performed to characterize the fibers and blocks and to determine the compressive strength of the units, prisms, and small walls. The deformation modulus of the elements was calculated and the stress-strain curves were plotted to gain a better understanding of the values obtained. The compression test results for the small walls reinforced with fibers were similar to those of the reference walls and better than the blocks and prisms with added fibers, which had resistances lower than those of the corresponding conventional materials. All elements prepared with the addition of sisal exhibited an increase in the deformation capacity (conferred by the fibers, which was observed in the stress-strain curves. The failure mode of the reference elements was characterized by an abrupt fracture, whereas the reinforced elements underwent ductile breakage. This result was because of the presence of the fibers, which remained attached to the faces of the cracks via adhesion to the cement matrix, thus preventing loss of continuity in the material. Therefore, the cement/plant fiber composites are advantageous in terms of their ductility and ability to resist further damage after cracking.

  12. Analysis of the applicability of acceleration methods for a triangular prism geometry nodal diffusion code

    International Nuclear Information System (INIS)

    Fujimura, Toichiro; Okumura, Keisuke

    2002-11-01

    A prototype version of a diffusion code has been developed to analyze the hexagonal core as reduced moderation reactor and the applicability of some acceleration methods have been investigated to accelerate the convergence of the iterative solution method. The hexagonal core is divided into regular triangular prisms in the three-dimensional code MOSRA-Prism and a polynomial expansion nodal method is applied to approximate the neutron flux distribution by a cubic polynomial. The multi-group diffusion equation is solved iteratively with ordinal inner and outer iterations and the effectiveness of acceleration methods is ascertained by applying an adaptive acceleration method and a neutron source extrapolation method, respectively. The formulation of the polynomial expansion nodal method is outlined in the report and the local and global effectiveness of the acceleration methods is discussed with various sample calculations. A new general expression of vacuum boundary condition, derived in the formulation is also described. (author)

  13. Development and commissioning of a double-prism spectrometer for the diagnosis of femtosecond electron bunches

    Energy Technology Data Exchange (ETDEWEB)

    Wunderlich, Steffen

    2016-12-15

    Free-electron lasers as accelerator-driven light sources and wakefield-based acceleration in plasmas require the knowledge of the longitudinal extension and the longitudinal current profile of the involved electron bunches. These bunches can yield lengths below 10 μm, or durations shorter than approx. 33 fs, as well as charges less than 30 pC. During this work, transition radiation from relativistic electron bunches was investigated in the mid-infrared wavelength regime. A spectrometer using an arrangement of two consecutive zinc selenide prisms was developed, built and commissioned. The instrument covers the spectral range from 2 μm to 18 μm in a single shot. Measurements with the double-prism spectrometer were conducted at the FEL facilities FLASH at DESY in Hamburg, Germany and FELIX at the Radboud Universiteit in Nijmegen, The Netherlands. The assessment of the spectrometer and comparative studies with established diagnostic devices at FLASH show high signal-to-noise ratios at bunch charges below 10 pC and confirm the obtained results.

  14. Improving clinical laboratory efficiency: a time-motion evaluation of the Abbott m2000 RealTime and Roche COBAS AmpliPrep/COBAS TaqMan PCR systems for the simultaneous quantitation of HIV-1 RNA and HCV RNA.

    Science.gov (United States)

    Amendola, Alessandra; Coen, Sabrina; Belladonna, Stefano; Pulvirenti, F Renato; Clemens, John M; Capobianchi, M Rosaria

    2011-08-01

    Diagnostic laboratories need automation that facilitates efficient processing and workflow management to meet today's challenges for expanding services and reducing cost, yet maintaining the highest levels of quality. Processing efficiency of two commercially available automated systems for quantifying HIV-1 and HCV RNA, Abbott m2000 system and Roche COBAS Ampliprep/COBAS TaqMan 96 (docked) systems (CAP/CTM), was evaluated in a mid/high throughput workflow laboratory using a representative daily workload of 24 HCV and 72 HIV samples. Three test scenarios were evaluated: A) one run with four batches on the CAP/CTM system, B) two runs on the Abbott m2000 and C) one run using the Abbott m2000 maxCycle feature (maxCycle) for co-processing these assays. Cycle times for processing, throughput and hands-on time were evaluated. Overall processing cycle time was 10.3, 9.1 and 7.6 h for Scenarios A), B) and C), respectively. Total hands-on time for each scenario was, in order, 100.0 (A), 90.3 (B) and 61.4 min (C). The interface of an automated analyzer to the laboratory workflow, notably system set up for samples and reagents and clean up functions, are as important as the automation capability of the analyzer for the overall impact to processing efficiency and operator hands-on time.

  15. Critically Tapered Wedges and Critical State Soil Mechanics: Porosity-based Pressure Prediction in the Nankai Accretionary Prism.

    Science.gov (United States)

    Flemings, P. B.; Saffer, D. M.

    2016-12-01

    We predict pore pressure from porosity measurements at ODP Sites 1174 and 808 in the Nankai Accretionary prism, offshore Japan. For a range of friction angles (5-30 degrees), we estimate that the pore pressure ratio (λ*) ranges from 0.5 to 0.8: the pore pressure supports 50% to 80% of the overburden. Higher friction angles result in higher pressures. For the majority of the scenarios, pressures within the prism parallel the lithostat and are greater than the pressures beneath it. Our results support previous qualitative interpretations at Nankai and elsewhere suggesting that lower porosity above the décollement than below reflects higher mean effective stress there. By coupling a critical state soil model (Modified Cam Clay), which describes porosity as a function of mean and deviator stress, with a stress model that considers the difference in stress states above and below the décollement, we quantitatively show that the prism porosities record significant overpressure despite their lower porosity. As the soil is consumed by the advancing prism, changes in both mean and shear stress drive overpressure generation. Even in the extreme case where only change in mean stress is considered (a vertical end cap model), significant overpressures are generated. The high pressures we predict require an effective friction coefficient (µb') at the décollement of 0.023-0.038. Assuming that the pore pressure at the décollement lies between the values we report for the wedge and the underthrusting sediments, these effective friction coefficients correspond to intrinsic friction coefficients of µb= 0.08-0.38 (f = 4.6 - 21°). These values are comparable to friction coefficients of 0.1-0.4 reported for clay-dominated fault zones in a wide range of settings. By coupling the critical wedge model with an appropriate constitutive model, we present a systematic approach to predict pressure in thrust systems.

  16. Polygonal Prism Mesh in the Viscous Layers for the Polyhedral Mesh Generator, PolyGen

    International Nuclear Information System (INIS)

    Lee, Sang Yong; Park, Chan Eok; Kim, Shin Whan

    2015-01-01

    Polyhedral mesh has been known to have some benefits over the tetrahedral mesh. Efforts have been made to set up a polyhedral mesh generation system with open source programs SALOME and TetGen. The evaluation has shown that the polyhedral mesh generation system is promising. But it is necessary to extend the capability of the system to handle the viscous layers to be a generalized mesh generator. A brief review to the previous works on the mesh generation for the viscous layers will be made in section 2. Several challenging issues for the polygonal prism mesh generation will be discussed as well. The procedure to generate a polygonal prism mesh will be discussed in detail in section 3. Conclusion will be followed in section 4. A procedure to generate meshes in the viscous layers with PolyGen has been successfully designed. But more efforts have to be exercised to find the best way for the generating meshes for viscous layers. Using the extrusion direction of the STL data will the first of the trials in the near future

  17. Compact surface plasmon resonance biosensor utilizing an injection-molded prism

    Science.gov (United States)

    Chen, How-Foo; Chen, Chih-Han; Chang, Yun-Hsiang; Chuang, Hsin-Yuan

    2016-05-01

    Targeting at a low cost and accessible diagnostic device in clinical practice, a compact surface plasmon resonance (SPR) biosensor with a large dynamic range in high sensitivity is designed to satisfy commercial needs in food safety, environmental bio-pollution monitoring, and fast clinical diagnosis. The core component integrates an optical coupler, a sample-loading plate, and angle-tuning reflectors is injection-molded as a free-from prism made of plastic optics. This design makes a matching-oil-free operation during operation. The disposability of this low-cost component ensures testing or diagnosis without cross contamination in bio-samples.

  18. Prism reactor system design and analysis of postulated unscrammed events

    International Nuclear Information System (INIS)

    Van Tuyle, G.J.; Slovik, G.C.

    1991-08-01

    Key safety characteristics of the PRISM reactor system include the passive reactor shutdown characteristic and the passive shutdown heat removal system, RVACS. While these characteristics are simple in principle, the physical processes are fairly complex, particularly for the passive reactor shutdown. It has been possible to adapt independent safety analysis codes originally developed for the Clinch River Breeder Reactor review, although some limitations remain. In this paper, the analyses of postulated unscrammed events are discussed, along with limitations in the predictive capabilities and plans to correct the limitations in the near future. 6 refs., 4 figs

  19. PRISM reactor system design and analysis of postulated unscrammed events

    International Nuclear Information System (INIS)

    Van Tuyle, G.J.; Slovik, G.C.; Rosztoczy, Z.; Lane, J.

    1991-01-01

    Key safety characteristics of the PRISM reactor system include the passive reactor shutdown characteristics and the passive shutdown heat removal system, RVACS. While these characteristics are simple in principle, the physical processes are fairly complex, particularly for the passive reactor shutdown. It has been possible to adapt independent safety analysis codes originally developed for the Clinch River Breeder Reactor review, although some limitations remain. In this paper, the analyses of postulated unscrammed events are discussed, along with limitations in the predictive capabilities and plans to correct the limitations in the near future. 6 refs., 4 figs

  20. Note: Using a Kösters prism to create a fringe pattern.

    Science.gov (United States)

    Capellmann, R F; Bewerunge, J; Platten, F; Egelhaaf, S U

    2017-05-01

    The interference of two crossed laser beams results in a standing wave. Such fringe patterns are exploited in different instruments such as interferometers or laser-Doppler anemometers. We create a fringe pattern in the sample plane of a microscope using a compact apparatus based on a Kösters prism. The fringe pattern is shown to be spatially and temporally very stable, covers a large area, and its spacing is easily tunable. In addition, we exploit it to impose a sinusoidal potential on colloidal particles.

  1. Foreword: Contributions of Arctic PRISM to monitoring western hemispheric shorebirds

    Science.gov (United States)

    Skagen, Susan K.; Smith, Paul A.; Andres, Brad A.; Donaldson, Garry; Brown, Stephen; Bart, Jonathan R.; Johnston, Victoria H.

    2012-01-01

    listing under the U.S. Endangered Species Act and the Canadian Species at Risk Act. To meet the need for information on population size and trends, shorebird biologists from Canada and the United States proposed a shared blueprint for shorebird monitoring across the Western Hemisphere in the late 1990s; this effort was undertaken in concert with the development of the Canadian and the U.S. Shorebird Conservation Plans. Soon thereafter, partners in the monitoring effort adopted the name "Program for Regional and International Shorebird Monitoring" (PRISM). Among the primary objectives of PRISM were to estimate the population sizes and trends of breeding North American shorebirds and describe their distributions. PRISM members evaluated ongoing and potential monitoring approached to address 74 taxa (including subspecies) and proposed a combination of arctic and boreal breeding surveys, temperate breeding and non-breeding surveys, and neotropical surveys.

  2. Rapid virological response assessment by Abbott RealTime hepatitis C virus assay for predicting sustained virological responses in patients with hepatitis C virus genotype 1 treated with pegylated-interferon and ribavirin

    Directory of Open Access Journals (Sweden)

    Pei-yuan Su

    2016-07-01

    Full Text Available The lower limits of virus detection of hepatitis C virus (HCV RNA detection assays are continuously improving. We aimed to assess the utility of more precise definition of 4th week viral load [rapid virological response (RVR] in predicting sustained virological response (SVR in HCV genotype 1 patients treated with pegylated-interferon (PEG-IFN and ribavirin. Clinical data of treatment-naïve HCV genotype 1 patients were retrospectively collected from 2009 to 2014. Patients were grouped according to 4th week viral load as follows: undetectable (n = 90 and detectable but not quantifiable (< 12 IU/mL, n = 27. All patients received PEG-IFNα-2a or -2b and ribavirin for 24 weeks. Serum HCV RNA levels were measured by Abbott RealTime (ART; Abbott Molecular, Abbott Park, IL, USA HCV assay. SVR was 95.5% and 63% in the undetectable group and < 12 IU/mL group of 4th week viral load, respectively. The between-group difference in SVR was significant (p < 0.001. We determined 4th week viral load was independently associated with SVR (odds ratio = 19.28; p = 0.002 and a good predictor of SVR [area under the curve (AUC = 0.775; p = 0.001]. ART HCV assays had a stronger SVR predictive value in HCV genotype 1 patients, indicating that only the undetectable group of 4th week viral load patients measured by ART HCV assay should be considered for shorter treatment time (24 weeks with PEG-IFN and ribavirin.

  3. Performance Results for the Prism Solar Installation at the New Mexico Regional Test Center: Field Data from February 15 - August 15 2016

    Energy Technology Data Exchange (ETDEWEB)

    Lave, Matthew Samuel [Sandia National Lab. (SNL-CA), Livermore, CA (United States). Photovoltaic and Distributed Systems Integration; Stein, Joshua S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photovoltaics and Distributed Systems Integration; Burnham, Laurie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Electric Power Systems Research

    2016-09-01

    A 9.6 kW test array of Prism bifacial modules and reference monofacial modules installed in February 2016 at the New Mexico Regional Test Center has produced six months of performance data. The data reveal that the Prism modules are out-performing the monofacial modules, with bifacial gains in energy over the six-month period ranging from 18% to 136%, depending on the orientation and ground albedo. These measured bifacial gains were found to be in good agreement with modeled bifacial gains using equations previously published by Prism. The most dramatic increase in performance was seen among the vertically tilted, west-facing modules, where the bifacial modules produced more than double the energy of monofacial modules and more energy than monofacial modules at any orientation. Because peak energy generation (mid-morning and mid-afternoon) for these bifacial modules may best match load on the electric grid, the west-facing orientation may be more economically desirable than traditional south-facing module orientations (which peak at solar noon).

  4. The StreamCat Dataset: Accumulated Attributes for NHDPlusV2 (Version 2.1) Catchments for the Conterminous United States: PRISM Normals Data

    Science.gov (United States)

    This dataset represents climate observations within individual, local NHDPlusV2 catchments and upstream, contributing watersheds. Attributes of the landscape layer were calculated for every local NHDPlusV2 catchment and accumulated to provide watershed-level metrics. (See Supplementary Info for Glossary of Terms) PRISM is a set of monthly, yearly, and single-event gridded data products of mean temperature and precipitation, max/min temperatures, and dewpoints, primarily for the United States. In-situ point measurements are ingested into the PRISM (Parameter elevation Regression on Independent Slopes Model) statistical mapping system. The PRISM products use a weighted regression scheme to account for complex climate regimes associated with orography, rain shadows, temperature inversions, slope aspect, coastal proximity, and other factors. (see Data Sources for links to NHDPlusV2 data and USGS Data) These data are summarized by local catchment and by watershed to produce local catchment-level and watershed-level metrics as a continuous data type (see Data Structure and Attribute Information for a description).

  5. Mechanical behavior in the Nankai inner accretionary prism, IODP Site C0002

    Science.gov (United States)

    Valdez, R. D., II; Saffer, D. M.

    2017-12-01

    Understanding the processes that control seismogenesis and stress state at subduction zones requires knowledge of fault zone and sediment physical and mechanical properties. As part of the International Ocean Discovery Program (IODP) Nankai Trough Seismogenic Zone Experiment (NanTroSEIZE), Expedition 348 drilled into the Kumano forearc basin and underlying inner accretionary prism at Site C0002, located 35 km landward of the trench. One primary objective was to sample and characterize the mechanical behavior of the inner accretionary prism. Here we report on the frictional and unconfined compressive strength (UCS) of mudstone samples and a clay-rich shear zone recovered from 2182-2209 meters below sea floor (mbsf), determined from triaxial deformation tests at confining pressures from 1 to 7 MPa (UCS measurements on mudstones) and 36 MPa (strength of fault zone). Our results show that at a confining pressure of 1 MPa, the wall rock sediments fail at a peak differential stress of 9.1 MPa with a residual stress of 2.8 MPa. A clear peak and evolution to residual strength remains present at 7 MPa, and both the peak and residual strengths of the mudstones increases systematically with confining pressure. At a confining pressure of 36 MPa, the shear zone sediment yields at a differential stress of 25.2 MPa followed by strain-hardening to a maximum stress of 33.1 MPa. The shear zone is frictionally weaker than the surrounding mudstones, with a friction coefficient (μ) of 0.26-0.31, versus µ = 0.45 for the wall rock. The suite of tests defines a UCS for the mudstone of 7.9 MPa. Our friction data suggest that the inner wedge may be weaker than commonly assumed in applications of critical wedge theory to estimate the properties and conditions in accretionary prisms. One key implication is that for a given basal detachment friction coefficient, higher basal pore pressures (or lower wedge pore pressures) would be required to sustain observed taper angles. Additionally, the

  6. Investigation of occult hepatitis B virus infection in anti-hbc positive patients from a liver clinic.

    Science.gov (United States)

    Martinez, Maria Carmela; Kok, Chee Choy; Baleriola, Cristina; Robertson, Peter; Rawlinson, William D

    2015-01-01

    Occult hepatitis B infection (OBI) is manifested by presence of very low levels (Hepatitis B viral DNA (HBV DNA) in the blood and the liver while exhibiting undetectable HBV surface antigen (HBsAg). The molecular mechanisms underlying this occurrence are still not completely understood. This study investigated the prevalence of OBI in a high-risk Australian population and compared the HBV S gene sequences of our cohort with reference sequences. Serum from HBV DNA positive, HBsAg negative, and hepatitis B core antibody (anti-HBc) positive patients (study cohort) were obtained from samples tested at SEALS Serology Laboratory using the Abbott Architect, as part of screening and diagnostic testing. From a total of 228,108 samples reviewed, 1,451 patients were tested for all three OBI markers. Only 10 patients (0.69%) out of the 1,451 patients were found to fit the selection criteria for OBI. Sequence analysis of the HBV S gene from 5 suspected OBI infected patients showed increased sequence variability in the 'a' epitope of the major hydrophilic region compared to reference sequences. In addition, a total of eight consistent nucleotide substitutions resulting in seven amino acid changes were observed, and three patients had truncated S gene sequence. These mutations appeared to be stable and may result in alterations in HBsAg conformation. These may negatively impact the affinity of hepatitis B surface antibody (anti-HBs) and may explain the false negative results in serological HBV diagnosis. These changes may also enable the virus to persist in the liver by evading immune surveillance. Further studies on a bigger cohort are required to determine whether these amino acid variations have been acquired in the process of immune escape and serve as markers of OBI.

  7. Stress distribution and pressure-bearing capacity of a high-pressure split-cylinder die with prism cavity

    Science.gov (United States)

    Zhao, Liang; Li, Mingzhe; Wang, Liyan; Qu, Erhu; Yi, Zhuo

    2018-03-01

    A novel high-pressure belt-type die with a split-type cylinder is investigated with respect to extending its lifetime and improving its pressure bearing capacity. Specifically, a tungsten carbide cylinder is split into several parts along the radial direction with a prism-type cavity. In this paper, the cylinders with different split numbers are chosen to study the stress distribution and compare them with the traditional belt-type die. The simulation results indicate that the split cylinder has much smaller stress than those in the belt-type cylinder, and the statistical analysis reveals that the split-pressure cylinder is able to bear higher pressure. Experimental tests also show that the high-pressure die with a split cylinder and prism cavity has a stronger pressure-bearing capacity than a belt-type die. The split cylinder has advantages of easy manufacturing, high pressure bearing capacity, and replaceable performance.

  8. Direct AFM observation of an opening event of a DNA cuboid constructed via a prism structure.

    Science.gov (United States)

    Endo, Masayuki; Hidaka, Kumi; Sugiyama, Hiroshi

    2011-04-07

    A cuboid structure was constructed using a DNA origami design based on a square prism structure. The structure was characterized by atomic force microscopy (AFM) and dynamic light scattering. The real-time opening event of the cuboid was directly observed by high-speed AFM.

  9. Establishment of detailed reference values for luteinizing hormone, follicle stimulating hormone, estradiol, and progesterone during different phases of the menstrual cycle on the Abbott ARCHITECT® analyzer

    OpenAIRE

    Stricker, Reto; Eberhart, Raphael; Chevailler, Marie-Christine; Quinn, Frank A.; Bischof, Paul; Stricker, René

    2017-01-01

    During a normal menstrual cycle, serum levels of luteinizing hormone (LH), follicle-stimulating hormone (FSH), estradiol, and progesterone can vary widely between cycles for the same woman, as well as between different woman. Reliable reference values based on the local population are important for correct interpretation of laboratory results. The purpose of our study was to determine detailed reference values for these hormones throughout the menstrual cycle using the Abbott ARCHITECT system...

  10. Using brain potentials to understand prism adaptation: the error-related negativity and the P300

    Directory of Open Access Journals (Sweden)

    Stephane Joseph Maclean

    2015-06-01

    Full Text Available Prism adaptation (PA is both a perceptual-motor learning task as well as a promising rehabilitation tool for visuo-spatial neglect (VSN – a spatial attention disorder often experienced after stroke resulting in slowed and/or inaccurate motor responses to contralesional targets. During PA, individuals are exposed to prism-induced shifts of the visual-field while performing a visuo-guided reaching task. After adaptation, with goggles removed, visuo-motor responding is shifted to the opposite direction of that initially induced by the prisms. This visuo-motor aftereffect has been used to study visuo-motor learning and adaptation and has been applied clinically to reduce VSN severity by improving motor responding to stimuli in contralesional (usually left-sided space. In order to optimize PA’s use for VSN patients, it is important to elucidate the neural and cognitive processes that alter visuomotor function during PA. In the present study, healthy young adults underwent PA while event-related potentials (ERPs were recorded at the termination of each reach (screen-touch, then binned according to accuracy (hit vs. miss and phase of exposure block (early, middle, late. Results show that two ERP components were evoked by screen-touch: an early error-related negativity (ERN, and a P300. The ERN was consistently evoked on miss trials during adaptation, while the P300 amplitude was largest during the early phase of adaptation for both hit and miss trials. This study provides evidence of two neural signals sensitive to visual feedback during PA that may sub-serve changes in visuomotor responding. Prior ERP research suggests that the ERN reflects an error processing system in medial-frontal cortex, while the P300 is suggested to reflect a system for context updating and learning. Future research is needed to elucidate the role of these ERP components in improving visuomotor responses among individuals with VSN.

  11. Using brain potentials to understand prism adaptation: the error-related negativity and the P300.

    Science.gov (United States)

    MacLean, Stephane J; Hassall, Cameron D; Ishigami, Yoko; Krigolson, Olav E; Eskes, Gail A

    2015-01-01

    Prism adaptation (PA) is both a perceptual-motor learning task as well as a promising rehabilitation tool for visuo-spatial neglect (VSN)-a spatial attention disorder often experienced after stroke resulting in slowed and/or inaccurate motor responses to contralesional targets. During PA, individuals are exposed to prism-induced shifts of the visual-field while performing a visuo-guided reaching task. After adaptation, with goggles removed, visuomotor responding is shifted to the opposite direction of that initially induced by the prisms. This visuomotor aftereffect has been used to study visuomotor learning and adaptation and has been applied clinically to reduce VSN severity by improving motor responding to stimuli in contralesional (usually left-sided) space. In order to optimize PA's use for VSN patients, it is important to elucidate the neural and cognitive processes that alter visuomotor function during PA. In the present study, healthy young adults underwent PA while event-related potentials (ERPs) were recorded at the termination of each reach (screen-touch), then binned according to accuracy (hit vs. miss) and phase of exposure block (early, middle, late). Results show that two ERP components were evoked by screen-touch: an error-related negativity (ERN), and a P300. The ERN was consistently evoked on miss trials during adaptation, while the P300 amplitude was largest during the early phase of adaptation for both hit and miss trials. This study provides evidence of two neural signals sensitive to visual feedback during PA that may sub-serve changes in visuomotor responding. Prior ERP research suggests that the ERN reflects an error processing system in medial-frontal cortex, while the P300 is suggested to reflect a system for context updating and learning. Future research is needed to elucidate the role of these ERP components in improving visuomotor responses among individuals with VSN.

  12. Scattering of a light wave by a thin fiber on or near a prism: experiment and analytical theory.

    Science.gov (United States)

    Tajima, Fumiaki; Nishiyama, Yoshio

    2012-06-01

    We have performed an experiment of the scattering of the near field on a prism created by a laser wave, evanescent wave (EW), or plane wave (PW) of an incident angle slightly larger than or smaller than the critical angle, by a thin fiber of subwavelength diameter set above the prism, and we made an analytical theory of an adapted model for the experiment. We have been able to analyze the experimental data exactly by the model theory better than any other theory we have ever known. The importance of the multiple interaction of the wave between the fiber and the surface and also the close similarity of the scattering characteristics between the EW and the PW mentioned above have been acknowledged by the analysis of the data obtained.

  13. Construction and immunological evaluation of truncated hepatitis B core particles carrying HBsAg amino acids 119–152 in the major immunodominant region (MIR)

    Energy Technology Data Exchange (ETDEWEB)

    Su, Qiudong; Yi, Yao [National Institute for Viral Disease Control and Prevention, China Center for Disease Control and Prevention, Changbai Road 155, Changping District, Beijing 102206 (China); Guo, Minzhuo [Beijing Entry-Exit Inspection and Quarantine Beureau, Tianshuiyuan Lane 6, Chaoyang District, Beijing 100026 (China); Qiu, Feng; Jia, Zhiyuan; Lu, Xuexin; Meng, Qingling [National Institute for Viral Disease Control and Prevention, China Center for Disease Control and Prevention, Changbai Road 155, Changping District, Beijing 102206 (China); Bi, Shengli, E-mail: shengli_bi@163.com [National Institute for Viral Disease Control and Prevention, China Center for Disease Control and Prevention, Changbai Road 155, Changping District, Beijing 102206 (China)

    2013-09-13

    Highlights: •The conformational HBV neutralization antigen domain was successfully displayed on the surface of truncated HBc particles. •Appropriate dialysis procedures to support the renaturing environment for the protein refolding. •Efficient purification procedures to obtain high purity and icosahedral particles of mosaic HBV antigen. •Strong immune responses not only including neutralization antibody response but also Th1 cell response were induced in mice. -- Abstract: Hepatitis B capsid protein expressed in Escherichia coli can reassemble into icosahedral particles, which could strongly enhance the immunogenicity of foreign epitopes, especially those inserted into its major immunodominant region. Herein, we inserted the entire ‘α’ antigenic determinant amino acids (aa) 119–152 of HBsAg into the truncated HBc (aa 1–144), between Asp{sup 78} and Pro{sup 79}. Prokaryotic expression showed that the mosaic HBc was mainly in the form of inclusion bodies. After denaturation with urea, it was dialyzed progressively for protein renaturation. We observed that before and after renaturation, mosaic HBc was antigenic as determined by HBsAg ELISA and a lot of viruslike particles were observed after renaturation. Thus, we further purified the mosaic viruslike particles by (NH{sub 4}){sub 2}SO{sub 4} precipitation, DEAE chromatography, and Sepharose 4FF chromatography. Negative staining electron microscopy demonstrated the morphology of the viruslike particles. Immunization of Balb/c mice with mosaic particles induced the production of anti-HBs antibody and Th1 cell immune response supported by ELISPOT and CD4/CD8 proportions assay. In conclusion, we constructed mosaic hepatitis core particles displaying the entire ‘α’ antigenic determinant on the surface and laid a foundation for researching therapeutic hepatits B vaccines.

  14. Applicability of PRISM PRA Methodology to the Level II Probabilistic Safety Analysis of KALIMER-600 (I) (Core Damage Event Tree Analysis Part)

    International Nuclear Information System (INIS)

    Park, S. Y.; Kim, T. W.; Ha, K. S.; Lee, B. Y.

    2009-03-01

    The Korea Atomic Energy Research Institute (KAERI) has been developing liquid metal reactor (LMR) design technologies under a National Nuclear R and D Program. Nevertheless, there is no experience of the PSA domestically for a fast reactor with the metal fuel. Therefore, the objective of this study is to establish the methodologies of risk assessment for the reference design of KALIMER-600 reactor. An applicability of the PSA of the PRISM plant to the KALIMER-600 has been studied. The study is confined to a core damage event tree analysis which is a part of a level 2 PSA. Assuming that the accident types, which can be developed from level 1 PSA, are same as the PRISM PRA, core damage categories are defined and core damage event trees are developed for the KALIMER-600 reactor. Fission product release fractions of the core damage categories and branch probabilities of the core damage event trees are referred from the PRISM PRA temporarily. Plant specific data will be used during the detail analysis

  15. Preparation of fluorinated Cr2O3 hexagonal prism and catalytic performance for the dehydrofluorination of 1,1-difluoroethane to vinyl fluoride

    Science.gov (United States)

    Han, Wenfeng; Li, Xiaojuan; Tang, Haodong; Wang, Zhikun; Xi, Miao; Li, Ying; Liu, Huazhang

    2015-09-01

    A Cr2O3 hexagonal prism structure synthesized via the reaction of aqueous CrCl3 solution with NaBH4 solution at room temperature followed by calcination of the precipitate in N2 atmosphere at 500 °C is investigated as an efficient catalyst for dehydrofluorination of 1,1-difluoroethane producing vinyl fluoride. With the assistance of scanning electron microscopy, transmission electron microscopy, and high-resolution transmission electron microscopy, experimental results revealed that the uniform hexagonal prism has a prism length of 285 ± 43 nm and width of 233 ± 33 nm. It is in the form of loose and net-like aggregation of nano-Cr2O3 with diameter less than 3-5 nm with polycrystalline structure. NH3 temperature programmed desorption and chlorodifluoromethane dismutation experiments confirm the existence of relatively abundant and strong acidic sites. As a catalyst for dehydrofluorination of 1,1-difluoroethane, compared with commercial Cr2O3, much higher activity and stability were observed due to the evolution of CrO x F y species and much higher surface area and mesoporous structure. No significant morphology changes or sintering of the catalyst are observed after 70-h reaction. Compared with the commercial Cr2O3, we suggest that the much smaller size of Cr2O3 crystalline which possesses higher surface energy, lower strength, and more abundant Lewis acidity and the formation of CrO x F y during reaction over hexagonal prism catalyst probably contributes to the activity and stability difference between these two catalysts.

  16. Role of Prism Decussation on Fatigue Crack Growth and Fracture of Human Enamel

    OpenAIRE

    Bajaj, Devendra; Arola, Dwayne

    2009-01-01

    The role of prism decussation on the crack growth resistance of human enamel is evaluated. Miniature inset Compact Tension (CT) specimens embodying a section of cuspal enamel were subjected to Mode I cyclic or monotonic loads. Cracks were grown in either the forward (from outer enamel inwards) or reverse (from inner enamel outwards) direction and the responses were compared quantitatively. Results showed that the outer enamel exhibits lower resistance to the inception and growth of cracks. Re...

  17. Single-domain versus two-domain configuration in thin ferromagnetic prisms

    International Nuclear Information System (INIS)

    Pini, Maria Gloria; Politi, Paolo

    2007-01-01

    Thin ferromagnetic elements in the form of rectangular prisms are theoretically investigated in order to study the transition from single-domain to two-domain state, with changing the in-plane aspect ratio p. We address two main questions: first, how general is the transition; second, how the critical value p c depends on the physical parameters. We use two complementary methods: discrete-lattice calculations and a micromagnetic continuum approach. Ultrathin films do not appear to split in two domains. Instead, thicker films may undergo the above transition. We have used the continuum approach to analyze recent magnetic force microscopy observations in 30nm-thick patterned permalloy elements, finding a good agreement for p c

  18. Accuracy and precision of four value-added blood glucose meters: the Abbott Optium, the DDI Prodigy, the HDI True Track, and the HypoGuard Assure Pro.

    Science.gov (United States)

    Sheffield, Catherine A; Kane, Michael P; Bakst, Gary; Busch, Robert S; Abelseth, Jill M; Hamilton, Robert A

    2009-09-01

    This study compared the accuracy and precision of four value-added glucose meters. Finger stick glucose measurements in diabetes patients were performed using the Abbott Diabetes Care (Alameda, CA) Optium, Diagnostic Devices, Inc. (Miami, FL) DDI Prodigy, Home Diagnostics, Inc. (Fort Lauderdale, FL) HDI True Track Smart System, and Arkray, USA (Minneapolis, MN) HypoGuard Assure Pro. Finger glucose measurements were compared with laboratory reference results. Accuracy was assessed by a Clarke error grid analysis (EGA), a Parkes EGA, and within 5%, 10%, 15%, and 20% of the laboratory value criteria (chi2 analysis). Meter precision was determined by calculating absolute mean differences in glucose values between duplicate samples (Kruskal-Wallis test). Finger sticks were obtained from 125 diabetes patients, of which 90.4% were Caucasian, 51.2% were female, 83.2% had type 2 diabetes, and average age of 59 years (SD 14 years). Mean venipuncture blood glucose was 151 mg/dL (SD +/-65 mg/dL; range, 58-474 mg/dL). Clinical accuracy by Clarke EGA was demonstrated in 94% of Optium, 82% of Prodigy, 61% of True Track, and 77% of the Assure Pro samples (P Abbott Optium was significantly more accurate than the other meter systems, whereas the HDI True Track was significantly less accurate and less precise compared to the other meter systems.

  19. FDS5 Simulation of PRISME INTEGRAL Test, PRSINT4

    International Nuclear Information System (INIS)

    Park, Jong Seok

    2012-01-01

    The reliance on fire modeling has playing a key role in the risk-informed and performance-based fire protection field. The ability to accurately predict fire behavior using the fire models is of high utility for hazard assessment, investigations and performance based design. Validation is the process of determining the degree of agreement between fire model outputs and real world events for one or more results of interest. The goal of validation is to quantify confidence in the predictive capability of the model. Validation in NUREG-1824 entails comparing the model prediction with full-scale fire experiments and quantifying the results. The objectives of this study, focused on the fire model validation, are to compare the FDS5 prediction results with the PRISME INTEGRAL test data and to validate FDS5 model

  20. APEX - the Hyperspectral ESA Airborne Prism Experiment

    Directory of Open Access Journals (Sweden)

    Koen Meuleman

    2008-10-01

    Full Text Available The airborne ESA-APEX (Airborne Prism Experiment hyperspectral mission simulator is described with its distinct specifications to provide high quality remote sensing data. The concept of an automatic calibration, performed in the Calibration Home Base (CHB by using the Control Test Master (CTM, the In-Flight Calibration facility (IFC, quality flagging (QF and specific processing in a dedicated Processing and Archiving Facility (PAF, and vicarious calibration experiments are presented. A preview on major applications and the corresponding development efforts to provide scientific data products up to level 2/3 to the user is presented for limnology, vegetation, aerosols, general classification routines and rapid mapping tasks. BRDF (Bidirectional Reflectance Distribution Function issues are discussed and the spectral database SPECCHIO (Spectral Input/Output introduced. The optical performance as well as the dedicated software utilities make APEX a state-of-the-art hyperspectral sensor, capable of (a satisfying the needs of several research communities and (b helping the understanding of the Earth’s complex mechanisms.

  1. Survey of fishes and environmental conditions in Abbotts Lagoon, Point Reyes National Seashore, California

    Science.gov (United States)

    Saiki, M.K.; Martin, B.A.

    2001-01-01

    This study was conducted to gain a better understanding of fishery resources in Abbotts Lagoon, Point Reyes National Seashore. During February/March, May, August, and November 1999, fish were sampled with floating variable-mesh gill nets and small minnow traps from as many as 14 sites in the lagoon. Water temperature, dissolved oxygen, pH, total ammonia(NH3 + NH4+), salinity, turbidity, water depth, and bottom substrate composition were also measured at each site. A total of 2,656 fish represented by eight species was captured during the study. Gill nets captured Sacramento perch, Archoplites interruptus; largemouth bass, Micropterus salmoides; Pacific herring, Clupea pallasi; prickly sculpin, Cottus asper, silver surfperch, Hyperprosopon ellipticum; longfin smelt, Spirinchus thaleichthys; and striped bass, Morone saxatilis; whereas minnow traps captured Sacramento perch; prickly sculpin; and threespine stickleback, Gasterosteus aculeatus. Cluster analysis (Ward's minimum variance method of fish catch statistics identified two major species assemblages-the first dominated by Sacramento perch and, to a lesser extent, by largemouth bass, and the second dominated by Pacific herring and threespine stickleback. Simple discriminant analysis of environmental variables indicated that salinity contributed the most towards separating the two assemblages.

  2. A 900 electrostatic prism for microparticle beam steering on a 2 MV van der Graaff dust accelerator

    International Nuclear Information System (INIS)

    Dixon, D.G.; Clarke, C.D.; McDonnell, J.A.M.; Dickason, R.E.; Flavill, R.P.

    1984-01-01

    The design and construction of a 90 0 electrostatic prism is described. The device is used to deflect hypervelocity dust particles produced in a horizontal van der Graaff accelerator to simulate micrometeoroid impacts on dusty lunar and asteroidal surfaces where vertical incidence must be provided. (author)

  3. The influence of hardening conditions on the properties of masonry cement mortar prisms made in brick moulds

    NARCIS (Netherlands)

    Bertram, G.; Lourenco, P.B.; Hasseltine, B.A.; Vasconseles, G.

    2014-01-01

    One aspect of our investigation into the spacing of movement joints involved the short and long term deformation of mortar embedded in masonry. In this research the influence of hardening conditions on the physical and mechanical properties of masonry cement mortar [M5] were studied. Mortar prisms

  4. Fast Focal Point Correction in Prism-Coupled Total Internal Reflection Scanning Imager Using an Electronically Tunable Lens

    Directory of Open Access Journals (Sweden)

    Chenggang Zhu

    2018-02-01

    Full Text Available Total internal reflection (TIR is useful for interrogating physical and chemical processes that occur at the interface between two transparent media. Yet prism-coupled TIR imaging microscopes suffer from limited sensing areas due to the fact that the interface (the object plane is not perpendicular to the optical axis of the microscope. In this paper, we show that an electrically tunable lens can be used to rapidly and reproducibly correct the focal length of an oblique-incidence scanning microscope (OI-RD in a prism-coupled TIR geometry. We demonstrate the performance of such a correction by acquiring an image of a protein microarray over a scan area of 4 cm2 with an effective resolution of less than 20 microns. The electronic focal length tuning eliminates the mechanical movement of the illumination lens in the scanning microscope and in turn the noise and background drift associated with the motion.

  5. On the Geometrically Nonlinear Elastic Response of Class θ = 1 Tensegrity Prisms

    Directory of Open Access Journals (Sweden)

    Ida Mascolo

    2018-03-01

    Full Text Available The present work studies the geometrically nonlinear response of class θ = 1 tensegrity prisms modeled as a collection of elastic springs reacting in tension (strings or cables or compression (bars, under uniform uniaxial loading. The incremental equilibrium equations of the structure are numerically solved through a path-following procedure, with the aim of modeling the mechanical behavior of the structure in the large displacement regime. Several numerical results are presented with reference to a variety of physical models, which use two different materials for the cables and the bars, and show different aspect ratios associated with either “standard” or “expanded” configurations. An experimental validation of the predicted constitutive response is conducted with reference to a “thick” and a “slender” model, observing rather good theory vs. experiment matching. The given numerical and experimental results highlight that the elastic response of the examined structures may switch from stiffening to softening, depending on the geometry of the system, the magnitude of the external load, and the applied prestress. The outcomes of the current study confirm previous literature results on the elastic response of minimal tensegrity prisms, and pave the way to the use of tensegrity systems as nonlinear spring units forming tunable mechanical metamaterials.

  6. Preparation of fluorinated Cr2O3 hexagonal prism and catalytic performance for the dehydrofluorination of 1,1-difluoroethane to vinyl fluoride

    International Nuclear Information System (INIS)

    Han, Wenfeng; Li, Xiaojuan; Tang, Haodong; Wang, Zhikun; Xi, Miao; Li, Ying; Liu, Huazhang

    2015-01-01

    A Cr 2 O 3 hexagonal prism structure synthesized via the reaction of aqueous CrCl 3 solution with NaBH 4 solution at room temperature followed by calcination of the precipitate in N 2 atmosphere at 500 °C is investigated as an efficient catalyst for dehydrofluorination of 1,1-difluoroethane producing vinyl fluoride. With the assistance of scanning electron microscopy, transmission electron microscopy, and high-resolution transmission electron microscopy, experimental results revealed that the uniform hexagonal prism has a prism length of 285 ± 43 nm and width of 233 ± 33 nm. It is in the form of loose and net-like aggregation of nano-Cr 2 O 3 with diameter less than 3–5 nm with polycrystalline structure. NH 3 temperature programmed desorption and chlorodifluoromethane dismutation experiments confirm the existence of relatively abundant and strong acidic sites. As a catalyst for dehydrofluorination of 1,1-difluoroethane, compared with commercial Cr 2 O 3 , much higher activity and stability were observed due to the evolution of CrO x F y species and much higher surface area and mesoporous structure. No significant morphology changes or sintering of the catalyst are observed after 70-h reaction. Compared with the commercial Cr 2 O 3 , we suggest that the much smaller size of Cr 2 O 3 crystalline which possesses higher surface energy, lower strength, and more abundant Lewis acidity and the formation of CrO x F y during reaction over hexagonal prism catalyst probably contributes to the activity and stability difference between these two catalysts.

  7. Inventory and review of existing PRISM hydrogeologic data for the Islamic Republic of Mauritania, Africa

    Science.gov (United States)

    Friedel, Michael J.

    2008-01-01

    The USGS entered into an agreement with the Mauritania Ministry of Mines and Industry to inventory and review the quality of information collected as part of the Project for Strengthening of the Institutions in the Mining Sector (PRISM). Whereas the PRISM program collected geophysical, geochemical, geological, satellite, and hydrogeologic information, this report focuses on an inventory and review of available hydrogeologic data provided to the USGS in multiple folders, files, and formats. Most of the information pertained to the hydrogeologic setting and the water budget of evaporation, evapotranspiration, and precipitation in the Choum-Zouerate area in northwestern Mauritania, and the country of Mauritania itself. Other information about the quantity and quality of groundwater was found in the relational Access database. In its present form, the limited hydrogeologic information was not amenable to conducting water balance, geostatistical, and localized numerical modeling studies in support of mineral exploration and development. Suggestions are provided to remedy many of the data's shortcomings, such as performing quality assurance on all SIPPE2 data tables and sending questionnaires to appropriate agencies, mining and other companies to populate the database with additional meteorology, hydrology, and groundwater data.

  8. The modular ALMR (PRISM) fuel cycle

    International Nuclear Information System (INIS)

    Thompson, M.L.

    1990-01-01

    The modular reactor concept, PRISM (power reactor, innovative, small module), originated by General Electric in conjunction with the integral fast reactor (IFR) metal fuel being developed by Argonne National Laboratory (ANL), is the reference US Department of Energy advanced liquid-metal reactor (ALMR). The reference ALMR is unique in several ways; for example, it can produce (or breed) substantially more fissile material than it consumes. It is also unique in that it has the capability to utilize as fuel the long-life radioactive actinides (primarily plutonium, and the minor actinides, neptunium, americium, and curium) present as waste in light water reactor (LWR) spent fuels. This capability provides a means for converting long-life actinide radioactive wastes to elements whose lifetimes and thus storage needs are much shorter, namely, hundreds of years. This could clearly focus and potentially alleviate a controversial aspect (waste disposal) of the nuclear option. While it does not change the need for, or timing of, an initial high-level waste (HLW) repository, the conversion of actinides could change in a dramatic way the time period required for safe storage of nuclear waste and potentially the number and criteria for future repositories. This work considers the potential for utilizing LWR actinides in the ALMR fuel cycle

  9. R&D proposal the prism plastic calorimeter:PPC

    CERN Document Server

    Dobrzynski, Ludwik; Marchand, P; Nédélec, P; Salin, P; CERN. Geneva. Detector Research and Development Committee

    1990-01-01

    This proposal supports two goals: First Goal_Demonstrate that current, widely used plastic technologies allow to design Prism Plastic Calorimeter (PPC) towers with a new "liquid crystal" type plastic called Vectra. It will be shown that this technique meets the requirements for a LHC calorimeter with warm liquids: safety, hermeticity, hadronic compensation, resolution and time response. Second Goal_ Describe how one can design a warm liquid calorimeter integrated into a LHC detector,and list the advantages of the PPC: low price, minimum of mechanical structures, minimum amount of dead space, easiness of mechanical assembly, accessibility to the electronics, possibility to recirculate the liquid. The absorber and the electronics being outside the liquid and easily accessible, one has maximum flexibility to define them. The R&D program we define here aims at showing the feasibility of these new ideas by building nine towers of twenty gaps and exposing them to electron and hadron beams.

  10. One Year Performance Results for the Prism Solar Installation at the New Mexico Regional Test Center: Field Data from February 15 2016 - February 14 2017.

    Energy Technology Data Exchange (ETDEWEB)

    Stein, Joshua [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Burnham, Laurie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lave, Matthew Samuel [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2017-06-01

    A 9.6 kW test array of Prism bifacial modules and reference monofacial modules installed in February 2016 at the New Mexico Regional Test Center has produced one year of performance data. The data reveal that the Prism modules are out-performing the monofacial modules, with bifacial gains in energy over the twelve-month period ranging from 17% to 132%, depending on the orientation and ground albedo. These measured bifacial gains were found to be in good agreement with modeled bifacial gains using equations previously published by Prism Solar. The most dramatic increase in performance was seen among the vertically mounted, west-facing modules, where the bifacial modules produced more than double the energy of monofacial modules in the same orientation. Because peak energy generation (mid- morning and mid-afternoon) for these bifacial modules may best match load on the electric grid, the west-facing orientation may be more economically desirable than traditional south-facing module orientations (which peak at solar noon).

  11. Reliability of tonosafe disposable tonometer prisms: clinical implications from the Veterans Affairs Boston Healthcare System Quality Assurance Study.

    Science.gov (United States)

    Thomas, V; Daly, M K; Cakiner-Egilmez, T; Baker, E

    2011-05-01

    Given the Veterans Affairs Boston Healthcare System's recent introduction of single-use Tonosafe disposable tonometer prisms as an alternative to Goldmann applanation tonometers (GATs), this study had two aims: to conduct a large-scale quality assurance trial to assess the reliability of intraocular pressure (IOP) measurements of the Tonosafe disposable tonometer compared with GAT, particularly at extremes of pressure; to evaluate the suitability of Tonosafe disposable tonometer prisms as an acceptable substitute for GATs and for clinic-wide implementation in an academic tertiary referral setting. Ophthalmology resident physicians measured the IOPs of patients in general and specialty eye clinics with the Tonosafe disposable tonometer and GAT. Tonosafe test-retest reliability data were also collected. A retrospective review of patient charts and data analysis were performed to determine the reliability of measurements. The IOPs of 652 eyes (326 patients) were measured with both GAT and Tonosafe, with a range of 3-34 mm Hg. Linear regression analysis showed R=0.93, slope=0.91, both of which supported the proposed hypothesis, and the y-intercept=-1.05 was significantly different from the hypothesized value. The Tonosafe test-retest repeatability (40 eyes of 40 patients), r=0.977, was very high, which was further supported by linear regression slope=0.993, y-intercept=0.118, and a Tonosafe repeatability coefficient of 2.06, similar to GAT repeatability. The IOP measurements by Tonosafe disposable prisms correlated closely with Goldmann measurements, with similar repeated measurement variability to GAT. This suggests that the Tonosafe is an acceptable substitute for GAT to measure IOP in ophthalmology clinic settings.

  12. PRISM, a Patient-Reported Outcome Instrument, Accurately Measures Symptom Change in Refractory Gastroesophageal Reflux Disease.

    Science.gov (United States)

    Fuller, Garth; Bolus, Roger; Whitman, Cynthia; Talley, Jennifer; Erder, M Haim; Joseph, Alain; Silberg, Debra G; Spiegel, Brennan

    2017-03-01

    Most patients with gastroesophageal reflux disease (GERD) experience relief following treatment with proton pump inhibitors (PPIs) (Vakil et al. in Am J Gastroenterol 101:1900-1920, 2006; Everhart and Ruhl in Gastroenterology 136:376-386, 2009). As many as 17-44% of patients, however, exhibit only partial response to therapy. Most extant GERD patient-reported outcome (PRO) instruments fail to meet development best practices as described by the FDA (Talley and Wiklund in Qual Life Res 14:21-33, 2005; Van Pinxteren et al. in Cochrane Database Syst Rev 18:CD002095, 2004; El-Serag et al. in Aliment Pharmacol Ther 32:720-737, 2010). To develop and validate a PRO instrument for clinical trials involving patients with GERD who are PPI partial responders. We prepared a systematic literature review, held patient focus groups, convened an expert panel, and conducted cognitive interviews to establish content validity. Eligible participants took PPI therapy for at least 8 weeks, had undergone an upper endoscopy, and scored at least 8 points on the GerdQ [6]. Qualitative data guided development of 26 draft items. Items were reviewed by expert panels and debriefed with patients. The resulting 21-item instrument underwent psychometric evaluation during a Phase IIB trial. During the trial, confirmatory factor analysis (n = 220) resulted in a four-factor model displaying the highest goodness of fit. All domains had a high inter-item correlation (Cronbach's α > 0.8). Test-retest reliability and convergent validity were strong, with highly significant (p < 0.01) correlations between average weekly PRISM scores and severity anchors and significant (p < 0.05) correlations with anchor subscales. Cumulative distribution functions revealed significant differences between responders and non-responders. Analysis in a clinical trial setting demonstrated strong psychometric properties suggesting validity of PRISM. Developed in line with FDA guidance on PROs, PRISM represents an

  13. A couple-focused intervention to prevent postnatal smoking relapse: PRISM study design.

    Science.gov (United States)

    Meghea, Cristian Ioan; Brînzaniuc, Alexandra; Mihu, Dan; Iuhas, Cristian Ioan; Stamatian, Florin; Caracostea, Gabriela; Sidor, Alexandra; Alexa, Paula Mădălina; Brînza, Cătălina; Pop, Oana Maria; Cherecheș, Răzvan Mircea

    2015-03-01

    Maternal smoking is one of the most modifiable factors with clear adverse effects for the fetus and the entire family. Addressing the dearth of pregnancy smoking interventions with partner support, PRISM (Prevent Relapse In SMoking) is a partnership between a research institution and the two largest state-owned obstetrics and gynecology clinics in Cluj-Napoca, Romania. The study will assess the efficacy of a couple-focused telephone-counseling program to prevent smoking relapse among mothers who quit smoking closely before or during pregnancy. The intervention is a program for couples based on motivational interviewing delivered over the phone after birth. The study is an ongoing randomized controlled trial of 250 Romanian women recruited soon after childbirth, who quit smoking in the six months before pregnancy or no later than the end of the first pregnancy trimester and remained abstinent (which was biochemically verified) until delivery. Participants were randomized to: (1) a control arm (usual care); and (2) an intervention arm consisting of up to 4 postnatal counseling calls for mothers and their partners using motivational interviewing to encourage the woman to remain smoke-free and the partner to support her decision. The primary outcome is maternal smoking abstinence at 6 months postpartum (biochemically verified). PRISM has the potential to identify strategies to reduce maternal postnatal relapse and increase partner quitting. If successful, the program may be an effective method to prevent and reduce smoking, which may lead to improved child, mother, and partner health both in the short and the long term. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. 'Redemption between politics and ontology: Agamben on the coming politics' [Review] Abbott, M (2014) The figure of this world: Agamben and the question of political ontology; Whyte, J (2014) Catastrophe and redemption: the political thought of Giorgio Agamben

    OpenAIRE

    Frost, Tom

    2016-01-01

    Review of: \\ud \\ud Abbott, M. (2014) The figure of this world: Agamben and the question of political ontology. Edinburgh: Edinburgh University Press, 9780748684090\\ud \\ud Whyte, J. (2014) Catastrophe and redemption: the political thought of Giorgio Agamben. Albany, NY: SUNY Press, 9781438448527

  15. Evaluation of postulated LOF [loss-of-flow] events in PRISM and SAFR

    International Nuclear Information System (INIS)

    Chan, B.C.; Van Tuyle, G.J.; Slovik, G.C.; Aronson, A.L.

    1987-01-01

    The PRISM and SAFR designs, as currently proposed by DOE, are designed for ''inherent'', as opposed to ''engineered'', safety. Brookhaven National Laboratory is supporting the initial NRC review of these advanced LMR concepts. A loss-of-flow (LOF) accident coupled with a failure of the reactor shutdown system is one of the major safety concerns in the advanced liquid metal reactor (LMR) evaluation effort. The analysis discussed here covers: (1) primary pipe break without pump trip, (2) primary coolant pump seizure, and (3) primary coolant pump coastdown. The analytical modelling and the calculated thermal and hydraulic behavior are described in detail

  16. The nature of the phenomenon “Event” in the prism of the conception by Gilles Deleuze

    Directory of Open Access Journals (Sweden)

    Pilyugina Elena Vladimirovna

    2014-12-01

    Full Text Available Through the prism of the “event” conception by G. Deleuze the article explores the ambivalent language and social nature of the event. It analyses references between attributes of the event: sign, meaning, and significance. It also defines the role of "floating signifiers" in the event and implementation of the virulent ideas and names into the system of event.

  17. Palatini wormholes and energy conditions from the prism of general relativity

    Energy Technology Data Exchange (ETDEWEB)

    Bejarano, Cecilia [Instituto de Astronomia y Fisica del Espacio (IAFE, CONICET-UBA), Buenos Aires (Argentina); Centro Mixto Universidad de Valencia-CSIC. Universidad de Valencia, Departamento de Fisica Teorica y IFIC, Valencia (Spain); Lobo, Francisco S.N.; Rubiera-Garcia, Diego [Faculdade de Ciencias da Universidade de Lisboa, Instituto de Astrofisica e Ciencias do Espaco, Lisbon (Portugal); Olmo, Gonzalo J. [Centro Mixto Universidad de Valencia-CSIC. Universidad de Valencia, Departamento de Fisica Teorica y IFIC, Valencia (Spain); Universidade Federal da Paraiba, Departamento de Fisica, Joao Pessoa, Paraiba (Brazil)

    2017-11-15

    Wormholes are hypothetical shortcuts in spacetime that in general relativity unavoidably violate all of the pointwise energy conditions. In this paper, we consider several wormhole spacetimes that, as opposed to the standard designer procedure frequently employed in the literature, arise directly from gravitational actions including additional terms resulting from contractions of the Ricci tensor with the metric, and which are formulated assuming independence between metric and connection (Palatini approach). We reinterpret such wormhole solutions under the prism of General Relativity and study the matter sources that thread them. We discuss the size of violation of the energy conditions in different cases and how this is related to the same spacetimes when viewed from the modified gravity side. (orig.)

  18. Testing of seismic isolation bearings for advanced liquid metal reactor prism

    International Nuclear Information System (INIS)

    Tajirian, F.F.; Kelly, J.M.

    1988-01-01

    Seismic isolation can significantly mitigate earthquake loads on liquid metal reactors (LMR), thus reducing the impact of seismic loads on design. This improves plant safety margins for beyond-design basis seismic events and enhances adaptability of a standardized design to a variety of sites, with potential cost benefits. The PRISM (Power Reactor Inherently Safe Module) LMR incorporates a horizontal isolation system which consists of high damping steel laminated rubber bearings. The results of an experimental program to determine the mechanical properties of the rubber compound and the bearing performance under different loading conditions are presented. The test results demonstrate the excellent performance of the bearings and their suitability for isolating compact LMR plants

  19. Palatini wormholes and energy conditions from the prism of general relativity.

    Science.gov (United States)

    Bejarano, Cecilia; Lobo, Francisco S N; Olmo, Gonzalo J; Rubiera-Garcia, Diego

    2017-01-01

    Wormholes are hypothetical shortcuts in spacetime that in general relativity unavoidably violate all of the pointwise energy conditions. In this paper, we consider several wormhole spacetimes that, as opposed to the standard designer procedure frequently employed in the literature, arise directly from gravitational actions including additional terms resulting from contractions of the Ricci tensor with the metric, and which are formulated assuming independence between metric and connection (Palatini approach). We reinterpret such wormhole solutions under the prism of General Relativity and study the matter sources that thread them. We discuss the size of violation of the energy conditions in different cases and how this is related to the same spacetimes when viewed from the modified gravity side.

  20. Summary of advanced LMR [Liquid Metal Reactor] evaluations: PRISM [Power Reactor Inherently Safe Module] and SAFR [Sodium Advanced Fast Reactor

    International Nuclear Information System (INIS)

    Van Tuyle, G.J.; Slovik, G.C.; Chan, B.C.; Kennett, R.J.; Cheng, H.S.; Kroeger, P.G.

    1989-10-01

    In support of the US Nuclear Regulatory Commission (NRC), Brookhaven National Laboratory (BNL) has performed independent analyses of two advanced Liquid Metal Reactor (LMR) concepts. The designs, sponsored by the US Department of Energy (DOE), the Power Reactor Inherently Safe Module (PRISM) [Berglund, 1987] and the Sodium Advanced Fast Reactor (SAFR) [Baumeister, 1987], were developed primarily by General Electric (GE) and Rockwell International (RI), respectively. Technical support was provided to DOE, RI, and GE, by the Argonne National Laboratory (ANL), particularly with respect to the characteristics of the metal fuels. There are several examples in both PRISM and SAFR where inherent or passive systems provide for a safe response to off-normal conditions. This is in contrast to the engineered safety systems utilized on current US Light Water Reactor (LWR) designs. One important design inherency in the LMRs is the ''inherent shutdown'', which refers to the tendency of the reactor to transition to a much lower power level whenever temperatures rise significantly. This type of behavior was demonstrated in a series of unscrammed tests at EBR-II [NED, 1986]. The second key design feature is the passive air cooling of the vessel to remove decay heat. These systems, designated RVACS in PRISM and RACS in SAFR, always operate and are believed to be able to prevent core damage in the event that no other means of heat removal is available. 27 refs., 78 figs., 3 tabs