WorldWideScience

Sample records for harmonized test method

  1. A harmonic pulse testing method for leakage detection in deep subsurface storage formations

    Science.gov (United States)

    Sun, Alexander Y.; Lu, Jiemin; Hovorka, Susan

    2015-06-01

    Detection of leakage in deep geologic storage formations (e.g., carbon sequestration sites) is a challenging problem. This study investigates an easy-to-implement frequency domain leakage detection technology based on harmonic pulse testing (HPT). Unlike conventional constant-rate pressure interference tests, HPT stimulates a reservoir using periodic injection rates. The fundamental principle underlying HPT-based leakage detection is that leakage modifies a storage system's frequency response function, thus providing clues of system malfunction. During operations, routine HPTs can be conducted at multiple pulsing frequencies to obtain experimental frequency response functions, using which the possible time-lapse changes are examined. In this work, a set of analytical frequency response solutions is derived for predicting system responses with and without leaks for single-phase flow systems. Sensitivity studies show that HPT can effectively reveal the presence of leaks. A search procedure is then prescribed for locating the actual leaks using amplitude and phase information obtained from HPT, and the resulting optimization problem is solved using the genetic algorithm. For multiphase flows, the applicability of HPT-based leakage detection procedure is exemplified numerically using a carbon sequestration problem. Results show that the detection procedure is applicable if the average reservoir conditions in the testing zone stay relatively constant during the tests, which is a working assumption under many other interpretation methods for pressure interference tests. HPT is a cost-effective tool that only requires periodic modification of the nominal injection rate. Thus it can be incorporated into existing monitoring plans with little additional investment.

  2. Nondestructive testing of hardness of grey iron casts by upper harmonics method

    International Nuclear Information System (INIS)

    Ershov, R.E.; Ivanenko, T.G.; Kuznetsky, S.S.; Mutovin, V.A.

    1982-01-01

    The relation between microstructure of grey iron and his surface hardness on the one hand and magnetic characteristics on the other hand has been investigated on toroidal samples. It is shown that surface hardness of grey iron and parameter a in Froelich formula are dependent linearly on the total surface of graphite inclusions. The conclusion was made that the testing of the grey iron hardness better to make by using the phase of the upper harmonics of the output signal of the overlain transducer. The coefficient of the linear correlation between readings corresponding device and the hardness is 0.86. (orig.)

  3. A Method for Harmonic Sources Detection based on Harmonic Distortion Power Rate

    Science.gov (United States)

    Lin, Ruixing; Xu, Lin; Zheng, Xian

    2018-03-01

    Harmonic sources detection at the point of common coupling is an essential step for harmonic contribution determination and harmonic mitigation. The harmonic distortion power rate index is proposed for harmonic source location based on IEEE Std 1459-2010 in the paper. The method only based on harmonic distortion power is not suitable when the background harmonic is large. To solve this problem, a threshold is determined by the prior information, when the harmonic distortion power is larger than the threshold, the customer side is considered as the main harmonic source, otherwise, the utility side is. A simple model of public power system was built in MATLAB/Simulink and field test results of typical harmonic loads verified the effectiveness of proposed method.

  4. Three-Phase Harmonic Analysis Method for Unbalanced Distribution Systems

    Directory of Open Access Journals (Sweden)

    Jen-Hao Teng

    2014-01-01

    Full Text Available Due to the unbalanced features of distribution systems, a three-phase harmonic analysis method is essential to accurately analyze the harmonic impact on distribution systems. Moreover, harmonic analysis is the basic tool for harmonic filter design and harmonic resonance mitigation; therefore, the computational performance should also be efficient. An accurate and efficient three-phase harmonic analysis method for unbalanced distribution systems is proposed in this paper. The variations of bus voltages, bus current injections and branch currents affected by harmonic current injections can be analyzed by two relationship matrices developed from the topological characteristics of distribution systems. Some useful formulas are then derived to solve the three-phase harmonic propagation problem. After the harmonic propagation for each harmonic order is calculated, the total harmonic distortion (THD for bus voltages can be calculated accordingly. The proposed method has better computational performance, since the time-consuming full admittance matrix inverse employed by the commonly-used harmonic analysis methods is not necessary in the solution procedure. In addition, the proposed method can provide novel viewpoints in calculating the branch currents and bus voltages under harmonic pollution which are vital for harmonic filter design. Test results demonstrate the effectiveness and efficiency of the proposed method.

  5. Dermal and inhalation acute toxic class methods: test procedures and biometric evaluations for the Globally Harmonized Classification System.

    Science.gov (United States)

    Holzhütter, H G; Genschow, E; Diener, W; Schlede, E

    2003-05-01

    The acute toxic class (ATC) methods were developed for determining LD(50)/LC(50) estimates of chemical substances with significantly fewer animals than needed when applying conventional LD(50)/LC(50) tests. The ATC methods are sequential stepwise procedures with fixed starting doses/concentrations and a maximum of six animals used per dose/concentration. The numbers of dead/moribund animals determine whether further testing is necessary or whether the test is terminated. In recent years we have developed classification procedures for the oral, dermal and inhalation routes of administration by using biometric methods. The biometric approach assumes a probit model for the mortality probability of a single animal and assigns the chemical to that toxicity class for which the best concordance is achieved between the statistically expected and the observed numbers of dead/moribund animals at the various steps of the test procedure. In previous publications we have demonstrated the validity of the biometric ATC methods on the basis of data obtained for the oral ATC method in two-animal ring studies with 15 participants from six countries. Although the test procedures and biometric evaluations for the dermal and inhalation ATC methods have already been published, there was a need for an adaptation of the classification schemes to the starting doses/concentrations of the Globally Harmonized Classification System (GHS) recently adopted by the Organization for Economic Co-operation and Development (OECD). Here we present the biometric evaluation of the dermal and inhalation ATC methods for the starting doses/concentrations of the GHS and of some other international classification systems still in use. We have developed new test procedures and decision rules for the dermal and inhalation ATC methods, which require significantly fewer animals to provide predictions of toxicity classes, that are equally good or even better than those achieved by using the conventional LD(50)/LC

  6. The harmonized INFOGEST in vitro digestion method

    NARCIS (Netherlands)

    Egger, Lotti; Ménard, Olivia; Delgado-Andrade, Cristina; Alvito, Paula; Assunção, Ricardo; Balance, Simon; Barberá, Reyes; Brodkorb, Andre; Cattenoz, Thomas; Clemente, Alfonso; Comi, Irene; Dupont, Didier; Garcia-Llatas, Guadalupe; Lagarda, María Jesús; Feunteun, Le Steven; Janssen Duijghuijsen, Lonneke; Karakaya, Sibel; Lesmes, Uri; Mackie, Alan R.; Martins, Carla; Meynier, Anne; Miralles, Beatriz; Murray, B.S.; Pihlanto, Anne; Picariello, Gianluca; Santos, C.N.; Simsek, Sebnem; Recio, Isidra; Rigby, Neil; Rioux, Laurie Eve; Stoffers, Helena; Tavares, Ana; Tavares, Lucelia; Turgeon, Sylvie; Ulleberg, E.K.; Vegarud, G.E.; Vergères, Guy; Portmann, Reto

    2016-01-01

    Within the active field of in vitro digestion in food research, the COST Action INFOGEST aimed to harmonize in vitro protocols simulating human digestion on the basis of physiologically inferred conditions. A harmonized static in vitro digestion (IVD) method was recently published as a primary

  7. Harmonic pulse testing for well performance monitoring

    NARCIS (Netherlands)

    Fokker, Peter A.; Salina Borello, Eloisa; Verga, Francesca; Viberti, Dario

    2018-01-01

    Harmonic testing was developed as a form of well testing that can be applied during ongoing production or injection operations, as a pulsed signal is superimposed on the background pressure trend. Thus no interruption of well and reservoir production is needed before and during the test. If the

  8. Towards an internationally harmonized test method for reproductive and developmental effects of endocrine disrupters in marine copepods

    DEFF Research Database (Denmark)

    Kusk, Kresten Ole; Wollenberger, Leah

    2007-01-01

    with marine copepods (Acartia tonsa, Nitocra spinipes, Tisbe battagliai, and Amphiascus tenuiremis). The present paper gives an overview on the endocrine system of crustaceans with special emphasis on development and reproduction, which are targets for endocrine disruption, and reviews available methods......New and updated methods to detect and characterize endocrine disrupting chemicals (EDCs) are urgently needed for the purpose of environmental risk assessment since these substances are often not detected using existing chronic toxicity tests. Numerous reports on the effects of EDCs on crustacean...... development and reproduction have been published and the development of life-cycle tests with crustaceans has been prioritized within the OECD work program for endocrine disrupter testing and assessment. As a result, Sweden, and Denmark initiated a proposal for development of a full life-cycle test...

  9. A class of discontinuous Petrov-Galerkin methods. Part IV: The optimal test norm and time-harmonic wave propagation in 1D

    KAUST Repository

    Zitelli, J.; Muga, Ignacio; Demkowicz, Leszek F.; Gopalakrishnan, Jayadeep; Pardo, David; Calo, Victor M.

    2011-01-01

    The phase error, or the pollution effect in the finite element solution of wave propagation problems, is a well known phenomenon that must be confronted when solving problems in the high-frequency range. This paper presents a new method with no phase errors for one-dimensional (1D) time-harmonic wave propagation problems using new ideas that hold promise for the multidimensional case. The method is constructed within the framework of the discontinuous Petrov-Galerkin (DPG) method with optimal test functions. We have previously shown that such methods select solutions that are the best possible approximations in an energy norm dual to any selected test space norm. In this paper, we advance by asking what is the optimal test space norm that achieves error reduction in a given energy norm. This is answered in the specific case of the Helmholtz equation with L2-norm as the energy norm. We obtain uniform stability with respect to the wave number. We illustrate the method with a number of 1D numerical experiments, using discontinuous piecewise polynomial hp spaces for the trial space and its corresponding optimal test functions computed approximately and locally. A 1D theoretical stability analysis is also developed. © 2010 Elsevier Inc.

  10. A class of discontinuous Petrov-Galerkin methods. Part IV: The optimal test norm and time-harmonic wave propagation in 1D

    KAUST Repository

    Zitelli, J.

    2011-04-01

    The phase error, or the pollution effect in the finite element solution of wave propagation problems, is a well known phenomenon that must be confronted when solving problems in the high-frequency range. This paper presents a new method with no phase errors for one-dimensional (1D) time-harmonic wave propagation problems using new ideas that hold promise for the multidimensional case. The method is constructed within the framework of the discontinuous Petrov-Galerkin (DPG) method with optimal test functions. We have previously shown that such methods select solutions that are the best possible approximations in an energy norm dual to any selected test space norm. In this paper, we advance by asking what is the optimal test space norm that achieves error reduction in a given energy norm. This is answered in the specific case of the Helmholtz equation with L2-norm as the energy norm. We obtain uniform stability with respect to the wave number. We illustrate the method with a number of 1D numerical experiments, using discontinuous piecewise polynomial hp spaces for the trial space and its corresponding optimal test functions computed approximately and locally. A 1D theoretical stability analysis is also developed. © 2010 Elsevier Inc.

  11. The pseudo-harmonics method applied to depletion calculation

    International Nuclear Information System (INIS)

    Silva, F.C. da; Amaral, J.A.C.; Thome, Z.D.

    1989-01-01

    In this paper, a new method for performing depletion calculations, based on the use of the Pseudo-Harmonics perturbation method, was developed. The fuel burnup was considered as a global perturbation and the multigroup difusion equations were rewriten in such a way as to treat the soluble boron concentration as the eigenvalue. By doing this, the critical boron concentration can be obtained by a perturbation method. A test of the new method was performed for a H 2 O-colled, D 2 O-moderated reactor. Comparison with direct calculation showed that this method is very accurate and efficient. (author) [pt

  12. Harmonic Mitigation Methods in Large Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Kocewiak, Łukasz Hubert; Chaudhary, Sanjay; Hesselbæk, Bo

    2013-01-01

    Various sources of harmonic problems in large wind power plants (WPPs) and optimized harmonic mitigation methods are presented in this paper. The harmonic problems such as sources of harmonic emission and amplification as well as harmonic stability are identified. Also modern preventive...... and remedial harmonic mitigation methods in terms of passive and active filtering are described. It is shown that WPP components such as long HVAC cables and park transformers can introduce significant low-frequency resonances which can affect wind turbine control system operation and overall WPP stability...... as well as amplification of harmonic distortion. It is underlined that there is a potential in terms of active filtering in modern grid-side converters in e.g. wind turbines, STATCOMs or HVDC stations utilized in modern large WPPs. It is also emphasized that the grid-side converter controller should...

  13. Acceleration test with mixed higher harmonics in HIMAC

    International Nuclear Information System (INIS)

    Kanazawa, M.; Sugiura, A.; Misu, T.

    2004-01-01

    In HIMAC synchrotron, beam tests with a magnetic ally loaded cavity have been performed. This cavity has very low Q-value of about 0.5, and can be added higher harmonics with fundamental acceleration frequency. In our tested system for higher harmonics, wave form of a DDS (Direct Digital Synthesizer) can be rewrite, and arbitrary wave form can be used for beam acceleration. In the beam test, second and third harmonic wave were added on the fundamental acceleration frequency, and increases of the accelerated beam intensity have been achieved. In this paper, results of the beam test and the acceleration system are presented. (author)

  14. International Harmonization and Cooperation in the Validation of Alternative Methods.

    Science.gov (United States)

    Barroso, João; Ahn, Il Young; Caldeira, Cristiane; Carmichael, Paul L; Casey, Warren; Coecke, Sandra; Curren, Rodger; Desprez, Bertrand; Eskes, Chantra; Griesinger, Claudius; Guo, Jiabin; Hill, Erin; Roi, Annett Janusch; Kojima, Hajime; Li, Jin; Lim, Chae Hyung; Moura, Wlamir; Nishikawa, Akiyoshi; Park, HyeKyung; Peng, Shuangqing; Presgrave, Octavio; Singer, Tim; Sohn, Soo Jung; Westmoreland, Carl; Whelan, Maurice; Yang, Xingfen; Yang, Ying; Zuang, Valérie

    The development and validation of scientific alternatives to animal testing is important not only from an ethical perspective (implementation of 3Rs), but also to improve safety assessment decision making with the use of mechanistic information of higher relevance to humans. To be effective in these efforts, it is however imperative that validation centres, industry, regulatory bodies, academia and other interested parties ensure a strong international cooperation, cross-sector collaboration and intense communication in the design, execution, and peer review of validation studies. Such an approach is critical to achieve harmonized and more transparent approaches to method validation, peer-review and recommendation, which will ultimately expedite the international acceptance of valid alternative methods or strategies by regulatory authorities and their implementation and use by stakeholders. It also allows achieving greater efficiency and effectiveness by avoiding duplication of effort and leveraging limited resources. In view of achieving these goals, the International Cooperation on Alternative Test Methods (ICATM) was established in 2009 by validation centres from Europe, USA, Canada and Japan. ICATM was later joined by Korea in 2011 and currently also counts with Brazil and China as observers. This chapter describes the existing differences across world regions and major efforts carried out for achieving consistent international cooperation and harmonization in the validation and adoption of alternative approaches to animal testing.

  15. An improved filtered spherical harmonic method for transport calculations

    International Nuclear Information System (INIS)

    Ahrens, C.; Merton, S.

    2013-01-01

    Motivated by the work of R. G. McClarren, C. D. Hauck, and R. B. Lowrie on a filtered spherical harmonic method, we present a new filter for such numerical approximations to the multi-dimensional transport equation. In several test problems, we demonstrate that the new filter produces results with significantly less Gibbs phenomena than the filter used by McClarren, Hauck and Lowrie. This reduction in Gibbs phenomena translates into propagation speeds that more closely match the correct propagation speed and solutions that have fewer regions where the scalar flux is negative. (authors)

  16. Application of potential harmonic expansion method to BEC ...

    Indian Academy of Sciences (India)

    We adopt the potential harmonics expansion method for an ab initio solu- ... commonly adopted mean-field theories, our method is capable of handling ..... potentials in self-consistent mean-field calculation [7] gives wrong results as the.

  17. Application of harmonic pulse testing to water-oil displacement

    NARCIS (Netherlands)

    Fokker, P.A.; Verga, F.

    2011-01-01

    Harmonic pulse testing is a well testing technique in which the injection or production rate is varied in a periodic way. The pressure response to the imposed rates, both in the pulser well and in the observer wells, can be analyzed in the frequency domain to evaluate the reservoir properties. The

  18. Study on UPF Harmonic Current Detection Method Based on DSP

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, H J [Northwestern Polytechnical University, Xi' an 710072 (China); Pang, Y F [Xi' an University of Technology, Xi' an 710048 (China); Qiu, Z M [Xi' an University of Technology, Xi' an 710048 (China); Chen, M [Northwestern Polytechnical University, Xi' an 710072 (China)

    2006-10-15

    Unity power factor (UPF) harmonic current detection method applied to active power filter (APF) is presented in this paper. The intention of this method is to make nonlinear loads and active power filter in parallel to be an equivalent resistance. So after compensation, source current is sinusoidal, and has the same shape of source voltage. Meanwhile, there is no harmonic in source current, and the power factor becomes one. The mathematic model of proposed method and the optimum project for equivalent low pass filter in measurement are presented. Finally, the proposed detection method applied to a shunt active power filter experimental prototype based on DSP TMS320F2812 is developed. Simulation and experiment results indicate the method is simple and easy to implement, and can obtain the real-time calculation of harmonic current exactly.

  19. Some Implicit Methods for Solving Harmonic Variational Inequalities

    Directory of Open Access Journals (Sweden)

    Muhammad Aslam Noor

    2016-08-01

    Full Text Available In this paper, we use the auxiliary principle technique to suggest an implicit method for solving the harmonic variational inequalities. It is shown that the convergence of the proposed method only needs pseudo monotonicity of the operator, which is a weaker condition than monotonicity.

  20. Application of potential harmonic expansion method to BEC

    Indian Academy of Sciences (India)

    We adopt the potential harmonics expansion method for an ab initio solution of the many-body system in a Bose condensate containing interacting bosons. Unlike commonly adopted mean-field theories, our method is capable of handling two-body correlation properly. We disregard three- and higher-body correlations.

  1. Evaluation of harmonic detection methods for active power filter applications

    DEFF Research Database (Denmark)

    Asiminoaei, Lucian; Blaabjerg, Frede; Hansen, Steffan

    2005-01-01

    In the attempt to minimize the harmonic disturbances created by the non-linear loads the choice of the active power filters comes out to improve the filtering efficiency and to solve many issues existing with classical passive filters. One of the key points for a proper implementation of an active...... theories. Then, the work here proposes a simulation setup that decouples the harmonic reference generator from the active filter model and its controller. In this way the selected methods can be equally analyzed and compared with respect to their performance, which helps anticipating possible...

  2. Quality of potential harmonics expansion method for dilute Bose ...

    Indian Academy of Sciences (India)

    Abstract. We present and examine an approximate but ab initio many-body approach, viz., potential harmonics expansion method (PHEM), which includes two-body correla- tions for dilute Bose–Einstein condensates. Comparing the total ground state energy for three trapped interacting bosons calculated in PHEM with the ...

  3. Pseudo-harmonics method: an application to thermal reactors

    International Nuclear Information System (INIS)

    Silva, F.C. da; Rotenberg, S.; Thome Filho, Z.D.

    1985-10-01

    Several applications of the Pseudo-Harmonics method are presented, aiming to calculate the neutron flux and the perturbed eigenvalue of a nuclear reactor, like PWR, with three enrichment regions as Angra-1 reactor. In the reference reactor, perturbations of several types as global as local were simulated. The results were compared with those from the direct calculation. (E.G.) [pt

  4. The resonating group method in an harmonic oscillator basis

    International Nuclear Information System (INIS)

    Silvestre-Brac, B.; Gignoux, C.; Ayant, Y.

    1987-05-01

    The scattering states for a general many body system is formulated within the resonating group method. The resulting Lippman-Schwinger equation is solved in an harmonic oscillator basis for which a number of advantages are emphasized. The analytical formula giving the free propagator in that basis is fully derived

  5. Simulation model of harmonics reduction technique using shunt active filter by cascade multilevel inverter method

    Science.gov (United States)

    Andreh, Angga Muhamad; Subiyanto, Sunardiyo, Said

    2017-01-01

    Development of non-linear loading in the application of industry and distribution system and also harmonic compensation becomes important. Harmonic pollution is an urgent problem in increasing power quality. The main contribution of the study is the modeling approach used to design a shunt active filter and the application of the cascade multilevel inverter topology to improve the power quality of electrical energy. In this study, shunt active filter was aimed to eliminate dominant harmonic component by injecting opposite currents with the harmonic component system. The active filter was designed by shunt configuration with cascaded multilevel inverter method controlled by PID controller and SPWM. With this shunt active filter, the harmonic current can be reduced so that the current wave pattern of the source is approximately sinusoidal. Design and simulation were conducted by using Power Simulator (PSIM) software. Shunt active filter performance experiment was conducted on the IEEE four bus test system. The result of shunt active filter installation on the system (IEEE four bus) could reduce THD current from 28.68% to 3.09%. With this result, the active filter can be applied as an effective method to reduce harmonics.

  6. HARMONIC ANALYSIS OF SVPWM INVERTER USING MULTIPLE-PULSES METHOD

    Directory of Open Access Journals (Sweden)

    Mehmet YUMURTACI

    2009-01-01

    Full Text Available Space Vector Modulation (SVM technique is a popular and an important PWM technique for three phases voltage source inverter in the control of Induction Motor. In this study harmonic analysis of Space Vector PWM (SVPWM is investigated using multiple-pulses method. Multiple-Pulses method calculates the Fourier coefficients of individual positive and negative pulses of the output PWM waveform and adds them together using the principle of superposition to calculate the Fourier coefficients of the all PWM output signal. Harmonic magnitudes can be calculated directly by this method without linearization, using look-up tables or Bessel functions. In this study, the results obtained in the application of SVPWM for values of variable parameters are compared with the results obtained with the multiple-pulses method.

  7. Joint inversion of hydraulic head and self-potential data associated with harmonic pumping tests

    Science.gov (United States)

    Soueid Ahmed, A.; Jardani, A.; Revil, A.; Dupont, J. P.

    2016-09-01

    Harmonic pumping tests consist in stimulating an aquifer by the means of hydraulic stimulations at some discrete frequencies. The inverse problem consisting in retrieving the hydraulic properties is inherently ill posed and is usually underdetermined when considering the number of well head data available in field conditions. To better constrain this inverse problem, we add self-potential data recorded at the ground surface to the head data. The self-potential method is a passive geophysical method. Its signals are generated by the groundwater flow through an electrokinetic coupling. We showed using a 3-D saturated unconfined synthetic aquifer that the self-potential method significantly improves the results of the harmonic hydraulic tomography. The hydroelectric forward problem is obtained by solving first the Richards equation, describing the groundwater flow, and then using the result in an electrical Poisson equation describing the self-potential problem. The joint inversion problem is solved using a reduction model based on the principal component geostatistical approach. In this method, the large prior covariance matrix is truncated and replaced by its low-rank approximation, allowing thus for notable computational time and storage savings. Three test cases are studied, to assess the validity of our approach. In the first test, we show that when the number of harmonic stimulations is low, combining the harmonic hydraulic and self-potential data does not improve the inversion results. In the second test where enough harmonic stimulations are performed, a significant improvement of the hydraulic parameters is observed. In the last synthetic test, we show that the electrical conductivity field required to invert the self-potential data can be determined with enough accuracy using an electrical resistivity tomography survey using the same electrodes configuration as used for the self-potential investigation.

  8. An accelerated life test model for harmonic drives under a segmental stress history and its parameter optimization

    Directory of Open Access Journals (Sweden)

    Zhang Chao

    2015-12-01

    Full Text Available Harmonic drives have various distinctive advantages and are widely used in space drive mechanisms. Accelerated life test (ALT is commonly conducted to shorten test time and reduce associated costs. An appropriate ALT model is needed to predict the lifetime of harmonic drives with ALT data. However, harmonic drives which are used in space usually work under a segmental stress history, and traditional ALT models can hardly be used in this situation. This paper proposes a dedicated ALT model for harmonic drives applied in space systems. A comprehensive ALT model is established and genetic algorithm (GA is adopted to obtain optimal parameters in the model using the Manson fatigue damage rule to describe the fatigue failure process and a cumulative damage method to calculate and accumulate the damage caused by each segment in the stress history. An ALT of harmonic drives was carried out and experimental results show that this model is acceptable and effective.

  9. Predicting chaos in memristive oscillator via harmonic balance method.

    Science.gov (United States)

    Wang, Xin; Li, Chuandong; Huang, Tingwen; Duan, Shukai

    2012-12-01

    This paper studies the possible chaotic behaviors in a memristive oscillator with cubic nonlinearities via harmonic balance method which is also called the method of describing function. This method was proposed to detect chaos in classical Chua's circuit. We first transform the considered memristive oscillator system into Lur'e model and present the prediction of the existence of chaotic behaviors. To ensure the prediction result is correct, the distortion index is also measured. Numerical simulations are presented to show the effectiveness of theoretical results.

  10. Four-harmonic database of laser-damage testing

    International Nuclear Information System (INIS)

    Rainer, F.; Atherton, L.J.; Campbell, J.H.; DeMarco, F.P.; Kozlowski, M.R.; Morgan, A.J.; Staggs, M.C.

    1991-01-01

    In the past two years we have made a sixfold expansion of our laser-damage database. Our primary emphasis has been with the fundamental 1064-nm irradiation generated by Nd:YAG. Because of the increasing need for high-threshold optics designed to operate in the UV, we include data covering the harmonics at 532, 355 and 266 nm. This is further supplemented with results of excimer-laser damage testing at 351 and 248 nm. The presented summaries cover over either years of complete data plus selected results spanning over a fourteen-year history of damage testing at LLNL using thirteen different laser systems. Besides the range of wavelengths, our parameter space covers pulse durations from < 1 ns to 84 ns, repetition rates from single shots to 6000 Hz, and irradiation modes from single shots to a variety of multiple-shot laser-conditioning techniques

  11. The Impact of Harmonics Calculation Methods on Power Quality Assessment in Wind Farms

    DEFF Research Database (Denmark)

    Kocewiak, Lukasz Hubert; Hjerrild, Jesper; Bak, Claus Leth

    2010-01-01

    Different methods of calculating harmonics in measurements obtained from offshore wind farms are shown in this paper. Appropriate data processing methods are suggested for harmonics with different origin and nature. Enhancements of discrete Fourier transform application in order to reduce...... measurement data processing errors are proposed and compared with classical methods. Comparison of signal processing methods for harmonic studies is presented and application dependent on harmonics origin and nature recommended. Certain aspects related to magnitude and phase calculation in stationary...... measurement data are analysed and described. Qualitative indices of measurement data harmonic analysis in order to assess the calculation accuracy are suggested and used....

  12. A method of solving simple harmonic oscillator Schroedinger equation

    Science.gov (United States)

    Maury, Juan Carlos F.

    1995-01-01

    A usual step in solving totally Schrodinger equation is to try first the case when dimensionless position independent variable w is large. In this case the Harmonic Oscillator equation takes the form (d(exp 2)/dw(exp 2) - w(exp 2))F = 0, and following W.K.B. method, it gives the intermediate corresponding solution F = exp(-w(exp 2)/2), which actually satisfies exactly another equation, (d(exp 2)/dw(exp 2) + 1 - w(exp 2))F = 0. We apply a different method, useful in anharmonic oscillator equations, similar to that of Rampal and Datta, and although it is slightly more complicated however it is also more general and systematic.

  13. The spherical harmonics method, 1 (general development of the theory)

    International Nuclear Information System (INIS)

    Mark, C.

    1957-02-01

    A method of obtaining approximate solutions of the transport equation is presented in a form applicable in principle to any geometry. The approximation will give good results in cases where the angular distribution is not very anisotropic. The basis of the approximation is to expand the density per unit solid angle Ψ(→/r, →/Ω) in spherical harmonic tensors formed from →/Ω the unit vector in the direction of velocity, and to break off the expansion. A differential equation whose degree increases with the order of the approximation is obtained for the total density Ψ (o) (r). This equation has the form where the numbers ν i depend on the order of the approximation and on the value of the parameter a of the medium, but not at all on the geometry. When the equation for the total density is an ordinary equation, we simulate the physical condition of continuity of Ψ(→/r, →/Ω) at a boundary in a multi-medium problem by requiring that the spherical harmonic moments of Ψ(→/r, →/Ω) which we retain be continuous; and this determines the constants in the solution for Ψ (o) (→/r. The form of the solution for the total density and the necessary moments in an approximation of general order is given explicitly for plane and spherical symmetry; and for cylindrical symmetry the solution is given for two low-order approximations. In a later report (CRT-338, Revised) the application of the method to several problems involving plane and spherical symmetry will be discussed in detail and the results of a number of examples already worked will also be given. (author)

  14. The spherical harmonics method, 1 (general development of the theory)

    Energy Technology Data Exchange (ETDEWEB)

    Mark, C

    1957-02-15

    A method of obtaining approximate solutions of the transport equation is presented in a form applicable in principle to any geometry. The approximation will give good results in cases where the angular distribution is not very anisotropic. The basis of the approximation is to expand the density per unit solid angle {Psi}({yields}/r, {yields}/{Omega}) in spherical harmonic tensors formed from {yields}/{Omega} the unit vector in the direction of velocity, and to break off the expansion. A differential equation whose degree increases with the order of the approximation is obtained for the total density {Psi}{sup (o)}(r). This equation has the form where the numbers {nu}{sub i} depend on the order of the approximation and on the value of the parameter a of the medium, but not at all on the geometry. When the equation for the total density is an ordinary equation, we simulate the physical condition of continuity of {Psi}({yields}/r, {yields}/{Omega}) at a boundary in a multi-medium problem by requiring that the spherical harmonic moments of {Psi}({yields}/r, {yields}/{Omega}) which we retain be continuous; and this determines the constants in the solution for {Psi}{sup (o)}({yields}/r. The form of the solution for the total density and the necessary moments in an approximation of general order is given explicitly for plane and spherical symmetry; and for cylindrical symmetry the solution is given for two low-order approximations. In a later report (CRT-338, Revised) the application of the method to several problems involving plane and spherical symmetry will be discussed in detail and the results of a number of examples already worked will also be given. (author)

  15. Recent applications of harmonic analysis to function spaces, differential equations, and data science novel methods in harmonic analysis

    CERN Document Server

    Gia, Quoc; Mayeli, Azita; Mhaskar, Hrushikesh; Zhou, Ding-Xuan

    2017-01-01

    The second of a two volume set on novel methods in harmonic analysis, this book draws on a number of original research and survey papers from well-known specialists detailing the latest innovations and recently discovered links between various fields. Along with many deep theoretical results, these volumes contain numerous applications to problems in signal processing, medical imaging, geodesy, statistics, and data science. The chapters within cover an impressive range of ideas from both traditional and modern harmonic analysis, such as: the Fourier transform, Shannon sampling, frames, wavelets, functions on Euclidean spaces, analysis on function spaces of Riemannian and sub-Riemannian manifolds, Fourier analysis on manifolds and Lie groups, analysis on combinatorial graphs, sheaves, co-sheaves, and persistent homologies on topological spaces. Volume II is organized around the theme of recent applications of harmonic analysis to function spaces, differential equations, and data science, covering topics such a...

  16. A novel method for detecting second harmonic ultrasonic components generated from fastened bolts

    Science.gov (United States)

    Fukuda, Makoto; Imano, Kazuhiko

    2012-09-01

    This study examines the use of ultrasonic second harmonic components in the quality control of bolt-fastened structures. An improved method for detecting the second harmonic components, from a bolt fastened with a nut, using the transmission method is constructed. A hexagon head iron bolt (12-mm diameter and 25-mm long) was used in the experiments. The bolt was fastened using a digital torque wrench. The second harmonic component increased by approximately 20 dB before and after the bolt was fastened. The sources of second harmonic components were contact acoustic nonlinearity in the screw thread interfaces of the bolt-nut and were the plastic deformation in the bolt with fastening bolt. This result was improved by approximately 10 dB compared with previous our method. Consequently, usefulness of the novel method for detecting second harmonic ultrasonic components generated from fastened bolt was confirmed.

  17. Harmonic voltage excess problem test and analysis in UHV and EHV grid particular operation mode

    Science.gov (United States)

    Lv, Zhenhua; Shi, Mingming; Fei, Juntao

    2018-02-01

    The test and analysis of the power quality of some 1000kV UHV transmission lines and 500kV EHV transmission lines is carried out. It is found that there is harmonic voltage excess problems when the power supply of the UHV and EHV voltage line is single-ended or single-loop, the problem basically disappeared after the operation mode change, different operating conditions, the harmonic current has not been greatly affected, indicating that the harmonic voltage changes mainly caused by the system harmonic impedance. With the analysis of MATLAB Simulink system model, it can be seen that there are specific harmonic voltage excess in the system under the specific operating mode, which results in serious distortion of the specific harmonic voltage. Since such phenomena are found in 500kV and 1000kV systems, it is suggested that the test evaluation work should be done under the typical mode of operation in 500kV, 1000kV Planning and construction process to prevent the occurrence of serious distortion and the regional harmonic current monitoring and suppression work should be done.

  18. The harmonics detection method based on neural network applied ...

    African Journals Online (AJOL)

    user

    Keywords: Artificial Neural Networks (ANN), p-q theory, (SAPF), Harmonics, Total ..... Genetic algorithm-based self-learning fuzzy PI controller for shunt active filter, ... Verification of global optimality of the OFC active power filters by means of ...

  19. Lack of harmonization in sweat testing for cystic fibrosis

    DEFF Research Database (Denmark)

    Lindegaard Christiansen, Anne; Nybo, Mads

    2014-01-01

    interpretation and referred literature. Results. 14 departments performed the sweat test. One department measured chloride and sodium concentration, while 13 departments measured conductivity. One department used a non-existing NPU code, two departments applied NPU codes inconsistent with the method performed......, four departments applied no NPU code and seven applied a correct NPU code. Ten of the departments measuring conductivity applied reference intervals. Nine departments measuring conductivity had recommendations of a normal area, a grey zone and a pathological value, while four departments only applied...... a normal and grey zone or a pathological value. Cut-off values for normal, grey and pathological areas were like the reference intervals inconsistent. Conclusion. There is inconsistent use of NPU codes, reference intervals and interpretation of sweat conductivity used in the process of diagnosing cystic...

  20. Frequency Domain Modeling and Simulation of DC Power Electronic Systems Using Harmonic State Space Method

    DEFF Research Database (Denmark)

    Kwon, Jun Bum; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    For the efficiency and simplicity of electric systems, the dc power electronic systems are widely used in a variety of applications such as electric vehicles, ships, aircraft and also in homes. In these systems, there could be a number of dynamic interactions and frequency coupling between network...... with different switching frequency or harmonics from ac-dc converters makes that harmonics and frequency coupling are both problems of ac system and challenges of dc system. This paper presents a modeling and simulation method for a large dc power electronic system by using Harmonic State Space (HSS) modeling...

  1. On-line reconstruction of in-core power distribution by harmonics expansion method

    International Nuclear Information System (INIS)

    Wang Changhui; Wu Hongchun; Cao Liangzhi; Yang Ping

    2011-01-01

    Highlights: → A harmonics expansion method for the on-line in-core power reconstruction is proposed. → A harmonics data library is pre-generated off-line and a code named COMS is developed. → Numerical results show that the maximum relative error of the reconstruction is less than 5.5%. → This method has a high computational speed compared to traditional methods. - Abstract: Fixed in-core detectors are most suitable in real-time response to in-core power distributions in pressurized water reactors (PWRs). In this paper, a harmonics expansion method is used to reconstruct the in-core power distribution of a PWR on-line. In this method, the in-core power distribution is expanded by the harmonics of one reference case. The expansion coefficients are calculated using signals provided by fixed in-core detectors. To conserve computing time and improve reconstruction precision, a harmonics data library containing the harmonics of different reference cases is constructed. Upon reconstruction of the in-core power distribution on-line, the two closest reference cases are searched from the harmonics data library to produce expanded harmonics by interpolation. The Unit 1 reactor of DayaBay Nuclear Power Plant (DayaBay NPP) in China is considered for verification. The maximum relative error between the measurement and reconstruction results is less than 5.5%, and the computing time is about 0.53 s for a single reconstruction, indicating that this method is suitable for the on-line monitoring of PWRs.

  2. Modified harmonic balance method for the solution of nonlinear jerk equations

    Science.gov (United States)

    Rahman, M. Saifur; Hasan, A. S. M. Z.

    2018-03-01

    In this paper, a second approximate solution of nonlinear jerk equations (third order differential equation) can be obtained by using modified harmonic balance method. The method is simpler and easier to carry out the solution of nonlinear differential equations due to less number of nonlinear equations are required to solve than the classical harmonic balance method. The results obtained from this method are compared with those obtained from the other existing analytical methods that are available in the literature and the numerical method. The solution shows a good agreement with the numerical solution as well as the analytical methods of the available literature.

  3. Hydraulic analysis of harmonic pumping tests in frequency and time domains for identifying the conduits networks in a karstic aquifer

    Science.gov (United States)

    Fischer, P.; Jardani, A.; Cardiff, M.; Lecoq, N.; Jourde, H.

    2018-04-01

    In a karstic field, the flow paths are very complex as they globally follow the conduit network. The responses generated from an investigation in this type of aquifer can be spatially highly variable. Therefore, the aim of the investigation in this case is to define a degree of connectivity between points of the field, in order to understand these flow paths. Harmonic pumping tests represent a possible investigation method for characterizing the subsurface flow of groundwater. They have several advantages compared to a constant-rate pumping (more signal possibilities, ease of extracting the signal in the responses and possibility of closed loop investigation). We show in this work that interpreting the responses from a harmonic pumping test is very useful for delineating a degree of connectivity between measurement points. We have firstly studied the amplitude and phase offset of responses from a harmonic pumping test in a theoretical synthetic modeling case in order to define a qualitative interpretation method in the time and frequency domains. Three different type of responses have been separated: a conduit connectivity response, a matrix connectivity, and a dual connectivity (response of a point in the matrix, but close to a conduit). We have then applied this method to measured responses at a field research site. Our interpretation method permits a quick and easy reconstruction of the main flow paths, and the whole set of field responses appear to give a similar range of responses to those seen in the theoretical synthetic case.

  4. Modernization of Physical Appearance and Solution Color Tests Using Quantitative Tristimulus Colorimetry: Advantages, Harmonization, and Validation Strategies.

    Science.gov (United States)

    Pack, Brian W; Montgomery, Laura L; Hetrick, Evan M

    2015-10-01

    Color measurements, including physical appearance, are important yet often misunderstood and underappreciated aspects of a control strategy for drug substances and drug products. From a patient safety perspective, color can be an important control point for detecting contamination, impurities, and degradation products, with human visual acuity often more sensitive for colored impurities than instrumental techniques such as HPLC. Physical appearance tests and solution color tests can also serve an important role in ensuring that appropriate steps are taken such that clinical trials do not become unblinded when the active material is compared with another product or a placebo. Despite the importance of color tests, compendial visual tests are not harmonized across the major pharmacopoeias, which results in ambiguous specifications of little value, difficult communication of true sample color, and significant extra work required for global registration. Some pharmacopoeias have not yet recognized or adopted technical advances in the instrumental measurement of color and appearance, whereas others begin to acknowledge the advantage of instrumental colorimetry, yet leave implementation of the technology ambiguous. This commentary will highlight the above-mentioned inconsistencies, provide an avenue toward harmonization and modernization, and outline a scientifically sound approach for implementing quantitative technologies for improved measurement, communication, and control of color and appearance for both solutions and solids. Importantly, this manuscript, for the first time, outlines a color method validation approach that is consistent with the International Conference on Harmonization's guidance on the topic of method validation. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.

  5. Study on A Control Method of PAPF for Resonance Damping and Harmonics Compensation in Power System

    DEFF Research Database (Denmark)

    Zhou, Fang; Wu, Longhui; Chen, Zhe

    2009-01-01

    In power system, capacitors are widely used to compensate reactive power, which generally cause resonance problems in harmonic distorted network. In this paper, A method of using a parallel active power filter (PAPF) to damp the resonances is proposed. The proposed method is compound with traditi......In power system, capacitors are widely used to compensate reactive power, which generally cause resonance problems in harmonic distorted network. In this paper, A method of using a parallel active power filter (PAPF) to damp the resonances is proposed. The proposed method is compound...... with traditional method, it shows that whether the capacitor current is included in the detecting current of PAPF or not. Also the PAPF with proposed method has strong ability in harmonic compensation. Finally, the experiment results are presented to verify the analysis....

  6. On the equivalence between the discrete ordinates and the spherical harmonics methods in radiative transfer

    International Nuclear Information System (INIS)

    Barichello, L.B.; Siewert, C.E.

    1998-01-01

    In this work concerning steady-state radiative-transfer calculations in plane-parallel media, the equivalence between the discrete ordinates method and the spherical harmonics method is proved. More specifically, it is shown that for standard radiative-transfer problems without the imposed restriction of azimuthal symmetry the two methods yield identical results for the radiation intensity when the quadrature scheme for the discrete ordinates method is defined by the zeros of the associated Legendre functions and when generalized Mark boundary conditions are used to define the spherical harmonics solution. It is also shown that, with these choices for a quadrature scheme and for the boundary conditions, the two methods can be formulated so as to require the same computational effort. Finally a justification for using the generalized Mark boundary conditions in the spherical harmonics solution is given

  7. 3-D spherical harmonics code FFT3 by the finite Fourier transformation method

    International Nuclear Information System (INIS)

    Kobayashi, K.

    1997-01-01

    In the odd order spherical harmonics method, the rigorous boundary condition at the material interfaces is that the even moments of the angular flux and the normal components of the even order moments of current vectors must be continuous. However, it is difficult to derive spatial discretized equations by the finite difference or finite element methods, which satisfy this material interface condition. It is shown that using the finite Fourier transformation method, space discretized equations which satisfy this interface condition can be easily derived. The discrepancies of the flux distribution near void region between spherical harmonics method codes may be due to the difference of application of the material interface condition. (author)

  8. Radiation transport benchmarks for simple geometries with void regions using the spherical harmonics method

    International Nuclear Information System (INIS)

    Kobayashi, K.

    2009-01-01

    In 2001, an international cooperation on the 3D radiation transport benchmarks for simple geometries with void region was performed under the leadership of E. Sartori of OECD/NEA. There were contributions from eight institutions, where 6 contributions were by the discrete ordinate method and only two were by the spherical harmonics method. The 3D spherical harmonics program FFT3 by the finite Fourier transformation method has been improved for this presentation, and benchmark solutions for the 2D and 3D simple geometries with void region by the FFT2 and FFT3 are given showing fairly good accuracy. (authors)

  9. Kinetic Modeling of Accelerated Stability Testing Enabled by Second Harmonic Generation Microscopy.

    Science.gov (United States)

    Song, Zhengtian; Sarkar, Sreya; Vogt, Andrew D; Danzer, Gerald D; Smith, Casey J; Gualtieri, Ellen J; Simpson, Garth J

    2018-04-03

    The low limits of detection afforded by second harmonic generation (SHG) microscopy coupled with image analysis algorithms enabled quantitative modeling of the temperature-dependent crystallization of active pharmaceutical ingredients (APIs) within amorphous solid dispersions (ASDs). ASDs, in which an API is maintained in an amorphous state within a polymer matrix, are finding increasing use to address solubility limitations of small-molecule APIs. Extensive stability testing is typically performed for ASD characterization, the time frame for which is often dictated by the earliest detectable onset of crystal formation. Here a study of accelerated stability testing on ritonavir, a human immunodeficiency virus (HIV) protease inhibitor, has been conducted. Under the condition for accelerated stability testing at 50 °C/75%RH and 40 °C/75%RH, ritonavir crystallization kinetics from amorphous solid dispersions were monitored by SHG microscopy. SHG microscopy coupled by image analysis yielded limits of detection for ritonavir crystals as low as 10 ppm, which is about 2 orders of magnitude lower than other methods currently available for crystallinity detection in ASDs. The four decade dynamic range of SHG microscopy enabled quantitative modeling with an established (JMAK) kinetic model. From the SHG images, nucleation and crystal growth rates were independently determined.

  10. Bulk characterization methods for non-centrosymmetric materials: second-harmonic generation, piezoelectricity, pyroelectricity, and ferroelectricity.

    Science.gov (United States)

    Ok, Kang Min; Chi, Eun Ok; Halasyamani, P Shiv

    2006-08-01

    Characterization methods for bulk non-centrosymmetric compounds are described. These methods include second-harmonic generation, piezoelectricity, pyroelectricity, and ferroelectricity. In this tutorial review with each phenomenon, details are given of the measurement techniques along with a brief history and background. Finally, data interpretation is discussed.

  11. Harmonic Stability Analysis of Offshore Wind Farm with Component Connection Method

    DEFF Research Database (Denmark)

    Hou, Peng; Ebrahimzadeh, Esmaeil; Wang, Xiongfei

    2017-01-01

    In this paper, an eigenvalue-based harmonic stability analysis method for offshore wind farm is proposed. Considering the internal cable connection layout, a component connection method (CCM) is adopted to divide the system into individual blocks as current controller of converters, LCL filters...

  12. The spherical harmonics method, II (application to problems with plane and spherical symmetry)

    Energy Technology Data Exchange (ETDEWEB)

    Mark, C

    1958-12-15

    The application of the spherical harmonic method to problems with plane or spherical symmetry is discussed in detail. The numerical results of some applications already made are included to indicate the degree of convergence obtained. Formulae for dealing with distributions of isotropic sources are developed. Tables useful in applying the method are given in Section 11. (author)

  13. The harmonics detection method based on neural network applied ...

    African Journals Online (AJOL)

    Several different methods have been used to sense load currents and extract its ... in order to produce a reference current in shunt active power filters (SAPF), and ... technique compared to other similar methods are found quite satisfactory by ...

  14. One dimension harmonic oscillator

    International Nuclear Information System (INIS)

    Cohen-Tannoudji, Claude; Diu, Bernard; Laloe, Franck.

    1977-01-01

    The importance of harmonic oscillator in classical and quantum physics, eigenvalues and eigenstates of hamiltonian operator are discussed. In complement are presented: study of some physical examples of harmonic oscillators; study of stationnary states in the /x> representation; Hermite polynomials; resolution of eigenvalue equation of harmonic oscillator by polynomial method; isotope harmonic oscillator with three dimensions; charged harmonic oscillator in uniform electric field; quasi classical coherent states of harmonic oscillator; eigenmodes of vibration of two coupled harmonic oscillators; vibration modus of a continuous physical system (application to radiation: photons); vibration modus of indefinite linear chain of coupled harmonic oscillators (phonons); one-dimensional harmonic oscillator in thermodynamic equilibrium at temperature T [fr

  15. Harmonic Instability Analysis of Single-Phase Grid Connected Converter using Harmonic State Space (HSS) modeling method

    DEFF Research Database (Denmark)

    Kwon, Jun Bum; Wang, Xiongfei; Bak, Claus Leth

    2015-01-01

    The increasing number of renewable energy sources at the distribution grid is becoming a major issue for utility companies, since the grid connected converters are operating at different operating points due to the probabilistic characteristics of renewable energy. Besides, typically, the harmonics...... proposes a new model of a single phase grid connected renewable energy source using the Harmonic State Space modeling approach, which is able to identify such problems and the model can be extended to be applied in the multiple connected converter analysis. The modeling results show the different harmonic...... and impedance from other renewable energy sources are not taken carefully into account in the installation and design. However, this may bring an unknown harmonic instability into the multiple power sourced system and also make the analysis difficult due to the complexity of the grid network. This paper...

  16. A novel power harmonic analysis method based on Nuttall-Kaiser combination window double spectrum interpolated FFT algorithm

    Science.gov (United States)

    Jin, Tao; Chen, Yiyang; Flesch, Rodolfo C. C.

    2017-11-01

    Harmonics pose a great threat to safe and economical operation of power grids. Therefore, it is critical to detect harmonic parameters accurately to design harmonic compensation equipment. The fast Fourier transform (FFT) is widely used for electrical popular power harmonics analysis. However, the barrier effect produced by the algorithm itself and spectrum leakage caused by asynchronous sampling often affects the harmonic analysis accuracy. This paper examines a new approach for harmonic analysis based on deducing the modifier formulas of frequency, phase angle, and amplitude, utilizing the Nuttall-Kaiser window double spectrum line interpolation method, which overcomes the shortcomings in traditional FFT harmonic calculations. The proposed approach is verified numerically and experimentally to be accurate and reliable.

  17. SHAF for Mitigation of Current Harmonics Using p-q Method with PI and Fuzzy Controllers

    Directory of Open Access Journals (Sweden)

    A. K. Panda

    2011-08-01

    Full Text Available Commencing with incandescent light bulb, every load today creates harmonics. Unfortunately, these loads vary with respect to their amount of harmonic content and response to problems caused by harmonics. Issue of Harmonics are of a greater concern to engineers, building designers and in industrial applications because they do more than distort voltage waveforms, they can overheat the building wiring, cause nuisance tripping, overheat transformer units, and cause random end-user equipment failures. Thus power quality has become more and more serious with each passing day. As a result active power filter (APF gains much more attention due to excellent harmonic compensation. But still the performance of the active filter seems to be in contradictions with different control techniques. The main objective of this paper is to analyse shunt active filter with fuzzy and pi controllers. To carry out the analysis, we consider active and reactive power method (p-q. Extensive simulations were carried out; simulations were performed with balance, unbalanced and non sinusoidal conditions. Simulation results validate the dynamic behaviour of fuzzy logic controller over pi controller.

  18. A multi-harmonic generalized energy balance method for studying autonomous oscillations of nonlinear conservative systems

    Science.gov (United States)

    Balaji, Nidish Narayanaa; Krishna, I. R. Praveen; Padmanabhan, C.

    2018-05-01

    The Harmonic Balance Method (HBM) is a frequency-domain based approximation approach used for obtaining the steady state periodic behavior of forced dynamical systems. Intrinsically these systems are non-autonomous and the method offers many computational advantages over time-domain methods when the fundamental period of oscillation is known (generally fixed as the forcing period itself or a corresponding sub-harmonic if such behavior is expected). In the current study, a modified approach, based on He's Energy Balance Method (EBM), is applied to obtain the periodic solutions of conservative systems. It is shown that by this approach, periodic solutions of conservative systems on iso-energy manifolds in the phase space can be obtained very efficiently. The energy level provides the additional constraint on the HBM formulation, which enables the determination of the period of the solutions. The method is applied to the linear harmonic oscillator, a couple of nonlinear oscillators, the elastic pendulum and the Henon-Heiles system. The approach is used to trace the bifurcations of the periodic solutions of the last two, being 2 degree-of-freedom systems demonstrating very rich dynamical behavior. In the process, the advantages offered by the current formulation of the energy balance is brought out. A harmonic perturbation approach is used to evaluate the stability of the solutions for the bifurcation diagram.

  19. Simulation of a Centrifugal Pump by Using the Harmonic Balance Method

    Directory of Open Access Journals (Sweden)

    Franco Magagnato

    2015-01-01

    Full Text Available The harmonic balance method was used for the flow simulation in a centrifugal pump. Independence studies have been done to choose proper number of harmonic modes and inlet eddy viscosity ratio value. The results from harmonic balance method show good agreements with PIV experiments and unsteady calculation results (which is based on the dual time stepping method for the predicted head and the phase-averaged velocity. A detailed analysis of the flow fields at different flow rates shows that the flow rate has an evident influence on the flow fields. At 0.6Qd, some vortices begin to appear in the impeller, and at 0.4Qd some vortices have blocked the flow passage. The flow fields at different positions at 0.6Qd and 0.4Qd show how the complicated flow phenomena are forming, developing, and even disappearing. The harmonic balance method can be used for the flow simulation in pumps, showing the same accuracy as unsteady methods, but is considerably faster.

  20. Higher harmonic imaging of tensile plastic deformation in loading and reloading processes by local resonance method

    International Nuclear Information System (INIS)

    Kawashima, Koichiro; Yasui, Hajime

    2015-01-01

    We have imaged plastically deformed region in a 5052 aluminum plate under tensile loading, unloading and reloading processes by using an immersion local resonance method. By transmitting large-amplitude burst wave of which frequency is a through-thickness resonant frequency of the plate, dislocation loops in plastic zone are forced to vibrate. The higher harmonic amplitude excited by the dislocation movement is mapped for the transducer position. The extension of plastic zone under monotonically increased loading, decrease in harmonic amplitude under unloading process and marked extension of plastic zone in reloading up to 0.4% plastic strain are clearly imaged. (author)

  1. Harmonic Issues Assessment on PWM VSC-Based Controlled Microgrids using Newton Methods

    DEFF Research Database (Denmark)

    Agundis-Tinajero, Gibran; Segundo-Ramirez, Juan; Peña-Gallardo, Rafael

    2018-01-01

    This paper presents the application of Newton-based methods in the time-domain for the computation of the periodic steady state solutions of microgrids with multiple distributed generation units, harmonic stability and power quality analysis. Explicit representation of the commutation process...... of the power electronic converters and closed-loop power management strategies are fully considered. Case studies under different operating scenarios are presented: grid-connected mode, islanded mode, variations in the Thevenin equivalent of the grid and the loads. Besides, the close relation between...... the harmonic distortion, steady state performance of the control systems, asymptotic stability and power quality is analyzed in order to evaluate the importance and necessity of using full models in stressed and harmonic distorted scenarios....

  2. Semi-classical quantization non-manifestly using the method of harmonic balance

    International Nuclear Information System (INIS)

    Stepanov, S.S.; Tutik, R.S.; Yaroshenko, A.P.; Schlippe, W. von.

    1990-01-01

    Based on the ideas of the harmonic balance method and h-expansion a semi-classical procedure for deriving approximations to the energy levels of one-dimensional quantum systems is developed. The procedure is applied to treat the perturbed oscillator potentials. 12 refs.; 2 tabs

  3. Harmonic tidal analysis at a few stations using the least squares method

    Digital Repository Service at National Institute of Oceanography (India)

    Fernandes, A.A.; Das, V.K.; Bahulayan, N.

    Using the least squares method, harmonic analysis has been performed on hourly water level records of 29 days at several stations depicting different types of non-tidal noise. For a tidal record at Mormugao, which was free from storm surges (low...

  4. A harmonic polynomial cell (HPC) method for 3D Laplace equation with application in marine hydrodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Yan-Lin, E-mail: yanlin.shao@dnvgl.com; Faltinsen, Odd M.

    2014-10-01

    We propose a new efficient and accurate numerical method based on harmonic polynomials to solve boundary value problems governed by 3D Laplace equation. The computational domain is discretized by overlapping cells. Within each cell, the velocity potential is represented by the linear superposition of a complete set of harmonic polynomials, which are the elementary solutions of Laplace equation. By its definition, the method is named as Harmonic Polynomial Cell (HPC) method. The characteristics of the accuracy and efficiency of the HPC method are demonstrated by studying analytical cases. Comparisons will be made with some other existing boundary element based methods, e.g. Quadratic Boundary Element Method (QBEM) and the Fast Multipole Accelerated QBEM (FMA-QBEM) and a fourth order Finite Difference Method (FDM). To demonstrate the applications of the method, it is applied to some studies relevant for marine hydrodynamics. Sloshing in 3D rectangular tanks, a fully-nonlinear numerical wave tank, fully-nonlinear wave focusing on a semi-circular shoal, and the nonlinear wave diffraction of a bottom-mounted cylinder in regular waves are studied. The comparisons with the experimental results and other numerical results are all in satisfactory agreement, indicating that the present HPC method is a promising method in solving potential-flow problems. The underlying procedure of the HPC method could also be useful in other fields than marine hydrodynamics involved with solving Laplace equation.

  5. Analysis of single-degree-of-freedom piezoelectric energy harvester with stopper by incremental harmonic balance method

    Science.gov (United States)

    Zhao, Dan; Wang, Xiaoman; Cheng, Yuan; Liu, Shaogang; Wu, Yanhong; Chai, Liqin; Liu, Yang; Cheng, Qianju

    2018-05-01

    Piecewise-linear structure can effectively broaden the working frequency band of the piezoelectric energy harvester, and improvement of its research can promote the practical process of energy collection device to meet the requirements for powering microelectronic components. In this paper, the incremental harmonic balance (IHB) method is introduced for the complicated and difficult analysis process of the piezoelectric energy harvester to solve these problems. After obtaining the nonlinear dynamic equation of the single-degree-of-freedom piecewise-linear energy harvester by mathematical modeling and the equation is solved based on the IHB method, the theoretical amplitude-frequency curve of open-circuit voltage is achieved. Under 0.2 g harmonic excitation, a piecewise-linear energy harvester is experimentally tested by unidirectional frequency-increasing scanning. The results demonstrate that the theoretical and experimental amplitudes have the same trend, and the width of the working band with high voltage output are 4.9 Hz and 4.7 Hz, respectively, and the relative error is 4.08%. The open-output peak voltage are 21.53 V and 18.25 V, respectively, and the relative error is 15.23%. Since the theoretical value is consistent with the experimental results, the theoretical model and the incremental harmonic balance method used in this paper are suitable for solving single-degree-of-freedom piecewise-linear piezoelectric energy harvester and can be applied to further parameter optimized design.

  6. Comparative analysis of approximations used in the methods of Faddeev equations and hyperspherical harmonics

    International Nuclear Information System (INIS)

    Mukhtarova, M.I.

    1988-01-01

    Comparative analysis of approximations, used in the methods of Faddeev equations and hyperspherical harmonics (MHH) was conducted. The differences in solutions of these methods, related with introduction of approximation of sufficient partial states into the three-nucleon problem, is shown. MHH method is preferred. It is shown that MHH advantage can be manifested clearly when studying new classes of interactions: three-particle, Δ-isobar, nonlocal and other interactions

  7. Solutions of transport equation in (X-Y-Z) three-dimensional geometry by finite element method and spherical harmonic expansion

    International Nuclear Information System (INIS)

    Fernandes, A.; Maiorino, J.R.

    1989-01-01

    This work presents a method to solve the neutron transport equation in thre space dimensions. The angular flux is aproximated by spherical harmonics and the finite element method is applied to the space component. The program originated by the analytical development is being tested and some results are presented. (author) [pt

  8. Nondestructive testing method

    International Nuclear Information System (INIS)

    Porter, J.F.

    1996-01-01

    Nondestructive testing (NDT) is the use of physical and chemical methods for evaluating material integrity without impairing its intended usefulness or continuing service. Nondestructive tests are used by manufaturer's for the following reasons: 1) to ensure product reliability; 2) to prevent accidents and save human lives; 3) to aid in better product design; 4) to control manufacturing processes; and 5) to maintain a uniform quality level. Nondestructive testing is used extensively on power plants, oil and chemical refineries, offshore oil rigs and pipeline (NDT can even be conducted underwater), welds on tanks, boilers, pressure vessels and heat exchengers. NDT is now being used for testing concrete and composite materials. Because of the criticality of its application, NDT should be performed and the results evaluated by qualified personnel. There are five basic nondestructive examination methods: 1) liquid penetrant testing - method used for detecting surface flaws in materials. This method can be used for metallic and nonmetallic materials, portable and relatively inexpensive. 2) magnetic particle testing - method used to detect surface and subsurface flaws in ferromagnetic materials; 3) radiographic testing - method used to detect internal flaws and significant variation in material composition and thickness; 4) ultrasonic testing - method used to detect internal and external flaws in materials. This method uses ultrasonics to measure thickness of a material or to examine the internal structure for discontinuities. 5) eddy current testing - method used to detect surface and subsurface flaws in conductive materials. Not one nondestructive examination method can find all discontinuities in all of the materials capable of being tested. The most important consideration is for the specifier of the test to be familiar with the test method and its applicability to the type and geometry of the material and the flaws to be detected

  9. Tooth Fracture Detection in Spiral Bevel Gears System by Harmonic Response Based on Finite Element Method

    Directory of Open Access Journals (Sweden)

    Yuan Chen

    2017-01-01

    Full Text Available Spiral bevel gears occupy several advantages such as high contact ratio, strong carrying capacity, and smooth operation, which become one of the most widely used components in high-speed stage of the aeronautical transmission system. Its dynamic characteristics are addressed by many scholars. However, spiral bevel gears, especially tooth fracture occurrence and monitoring, are not to be investigated, according to the limited published issues. Therefore, this paper establishes a three-dimensional model and finite element model of the Gleason spiral bevel gear pair. The model considers the effect of tooth root fracture on the system due to fatigue. Finite element method is used to compute the mesh generation, set the boundary condition, and carry out the dynamic load. The harmonic response spectra of the base under tooth fracture are calculated and the influence of main parameters on monitoring failure is investigated as well. The results show that the change of torque affects insignificantly the determination of whether or not the system has tooth fracture. The intermediate frequency interval (200 Hz–1000 Hz is the best interval to judge tooth fracture occurrence. The best fault test region is located in the working area where the system is going through meshing. The simulation calculation provides a theoretical reference for spiral bevel gear system test and fault diagnosis.

  10. Functional geometric method for solving free boundary problems for harmonic functions

    Energy Technology Data Exchange (ETDEWEB)

    Demidov, Aleksander S [M. V. Lomonosov Moscow State University, Moscow (Russian Federation)

    2010-01-01

    A survey is given of results and approaches for a broad spectrum of free boundary problems for harmonic functions of two variables. The main results are obtained by the functional geometric method. The core of these methods is an interrelated analysis of the functional and geometric characteristics of the problems under consideration and of the corresponding non-linear Riemann-Hilbert problems. An extensive list of open questions is presented. Bibliography: 124 titles.

  11. Improved time-dependent harmonic oscillator method for vibrationally inelastic collisions

    International Nuclear Information System (INIS)

    DePristo, A.E.

    1985-01-01

    A quantal solution to vibrationally inelastic collisions is presented based upon a linear expansion of the interaction potential around the time-dependent classical positions of all translational and vibrational degrees of freedom. The full time-dependent wave function is a product of a Gaussian translational wave packet and a multidimensional harmonic oscillator wave function, both centered around the appropriate classical position variables. The computational requirements are small since the initial vibrational coordinates are the equilibrium values in the classical trajectory (i.e., phase space sampling does not occur). Different choices of the initial width of the translational wave packet and the initial classical translational momenta are possible, and two combinations are investigated. The first involves setting the initial classical momenta equal to the quantal expectation value, and varying the width to satisfy normalization of the transition probability matrix. The second involves adjusting the initial classical momenta to ensure detailed balancing for each set of transitions, i→f and f→i, and varying the width to satisfy normalization. This choice illustrates the origin of the empirical correction of using the arithmetic average momenta as the initial classical momenta in the forced oscillator approximation. Both methods are tested for the collinear collision systems CO 2 --(He, Ne), and are found to be accurate except for near-resonant vibration--vibration exchange at low initial kinetic energies

  12. Harmonic current layer method for the design of superconducting quadrupole magnetic field

    International Nuclear Information System (INIS)

    Zizek, F.

    1977-01-01

    The magnetic field of a superconducting quadrupole is investigated by the method of harmonic current layers of cylindrical shape. The superconducting winding is replaced by a system of thin current layers with a harmonically distributed density of the surface current along the circumference. The effect of the outer ferromagnetic circuit with an arbitrary constant permeability over the cross section is replaced analogically. The resultant magnetic field is then given by the superposition of the contributions from the individual current layers. The calculation method can be modified for the selection of the geometry of the winding for the latter to meet the demand for the high homogeneity of the gradient of magnetic induction in the working space of the superconducting quadrupole. (author)

  13. Computing multiple periodic solutions of nonlinear vibration problems using the harmonic balance method and Groebner bases

    Science.gov (United States)

    Grolet, Aurelien; Thouverez, Fabrice

    2015-02-01

    This paper is devoted to the study of vibration of mechanical systems with geometric nonlinearities. The harmonic balance method is used to derive systems of polynomial equations whose solutions give the frequency component of the possible steady states. Groebner basis methods are used for computing all solutions of polynomial systems. This approach allows to reduce the complete system to an unique polynomial equation in one variable driving all solutions of the problem. In addition, in order to decrease the number of variables, we propose to first work on the undamped system, and recover solution of the damped system using a continuation on the damping parameter. The search for multiple solutions is illustrated on a simple system, where the influence of the retained number of harmonic is studied. Finally, the procedure is applied on a simple cyclic system and we give a representation of the multiple states versus frequency.

  14. An experimental magnetic moment determination method based on spatial harmonic analysis of magnetic flux density signatures

    Directory of Open Access Journals (Sweden)

    A.V. Getman

    2013-12-01

    Full Text Available Theoretical aspects of an experimental determination method for residual and inductive magnetic moments of a technical object are considered. As input data, the technical object magnetic induction signatures obtained under its linear movement near a pair of three-component sensors are used. A magnetic signature integration technique based on spatial harmonic analysis of the magnetic field represented by twenty-four multipole coefficients is introduced.

  15. Bipolar harmonics method in the semiclassical theory of sub-doppler cooling

    International Nuclear Information System (INIS)

    Bezverbnyi, A.V.

    2000-01-01

    The bipolar harmonics method is extended to the case of complex elliptic polarization vectors. The method is used to study, on the basis of the semiclassical theory, the multipole moments of the ground state of atoms under conditions of sub-Doppler cooling with a monochromatic light field possessing spatial gradients of the polarization. It is shown that for stationary atoms with an initial isotropic distribution over sublevels the multipole moments of rank κ decompose, in accordance with the parity κ of the rank, according to one of two minimal sets of bipolar harmonics with different symmetry under inversion. An expansion of the corrections, which are linear in the velocity, to the multipole moments with respect to the indicated minimal sets of bipolar harmonics is studied for a stationary state, and the expansion coefficients are analyzed. The orientation vector J of the atomic ensemble is studied on the basis of the proposed method for the dipole transition 1/2 → 1/2, and the light-induced forces for a specific 2D configuration of the light field, including radiation friction forces and Lorentz-type forces, are analyzed

  16. Frames and other bases in abstract and function spaces novel methods in harmonic analysis

    CERN Document Server

    Gia, Quoc; Mayeli, Azita; Mhaskar, Hrushikesh; Zhou, Ding-Xuan

    2017-01-01

    The first of a two volume set on novel methods in harmonic analysis, this book draws on a number of original research and survey papers from well-known specialists detailing the latest innovations and recently discovered links between various fields. Along with many deep theoretical results, these volumes contain numerous applications to problems in signal processing, medical imaging, geodesy, statistics, and data science. The chapters within cover an impressive range of ideas from both traditional and modern harmonic analysis, such as: the Fourier transform, Shannon sampling, frames, wavelets, functions on Euclidean spaces, analysis on function spaces of Riemannian and sub-Riemannian manifolds, Fourier analysis on manifolds and Lie groups, analysis on combinatorial graphs, sheaves, co-sheaves, and persistent homologies on topological spaces. Volume I is organized around the theme of frames and other bases in abstract and function spaces, covering topics such as: The advanced development of frames, including ...

  17. A New Soft Computing Method for K-Harmonic Means Clustering.

    Science.gov (United States)

    Yeh, Wei-Chang; Jiang, Yunzhi; Chen, Yee-Fen; Chen, Zhe

    2016-01-01

    The K-harmonic means clustering algorithm (KHM) is a new clustering method used to group data such that the sum of the harmonic averages of the distances between each entity and all cluster centroids is minimized. Because it is less sensitive to initialization than K-means (KM), many researchers have recently been attracted to studying KHM. In this study, the proposed iSSO-KHM is based on an improved simplified swarm optimization (iSSO) and integrates a variable neighborhood search (VNS) for KHM clustering. As evidence of the utility of the proposed iSSO-KHM, we present extensive computational results on eight benchmark problems. From the computational results, the comparison appears to support the superiority of the proposed iSSO-KHM over previously developed algorithms for all experiments in the literature.

  18. The pseudo-harmonics method: an application involving perturbations caused by control rod insertion in PWR reactors

    International Nuclear Information System (INIS)

    Claro, L.H.; Alvim, A.C.M.; Thome, Z.D.

    1988-08-01

    The objective of this work is to stydy the effect of intense perturbations, such as control rod insertion in the core of PWR reactors, through a perturbation approach consisting of a modified version of the pseudo-harmonics method. A typical one-dimensional PWR reactor model was used as a reference state, from which two perturbations were imposed, simulation gray and black control rod insertion. In the first case, eigenvalue convergence was achieved with the eighth order of approximation approximation and perturbed fluxes and eigenvalue estimates agreed very well with direct calculation results. The second case tested represents a very intense localized perturbation. Oscillation in keff were observed er of approximation increased and the method failed to converge. Results obtained indicate that the pseudo-harmonics method can be used to compute 2 group fluxes and fundamental eigenvalue of perturbated states resulting from gray control rod insertion in PWR reactors. The method is limited, however, by perturbation intensity, as other perturbation methods are. (author) [pt

  19. Periodic Solutions of the Duffing Harmonic Oscillator by He's Energy Balance Method

    Directory of Open Access Journals (Sweden)

    A. M. El-Naggar

    2015-11-01

    Full Text Available Duffing harmonic oscillator is a common model for nonlinear phenomena in science and engineering. This paper presents He´s Energy Balance Method (EBM for solving nonlinear differential equations. Two strong nonlinear cases have been studied analytically. Analytical results of the EBM are compared with the solutions obtained by using He´s Frequency Amplitude Formulation (FAF and numerical solutions using Runge-Kutta method. The results show the presented method is potentially to solve high nonlinear oscillator equations.

  20. Diagnostic laboratory tests for systemic autoimmune rheumatic diseases: unmet needs towards harmonization.

    Science.gov (United States)

    Meroni, Pier Luigi; Borghi, Maria Orietta

    2018-05-01

    Autoantibodies are helpful tools not only for the diagnosis and the classification of systemic autoimmune rheumatic diseases (SARD) but also for sub-grouping patients and/or for monitoring disease activity or specific tissue/organ damage. Consequently, the role of the diagnostic laboratory in the management of SARD is becoming more and more important. The advent of new techniques raised the need of updating and harmonizing our use/interpretation of the assays. We discuss in this opinion paper some of these issues. Indirect immunofluorescence (IIF) was originally suggested as the reference technique for anti-nuclear antibody (ANA) detection as previous solid phase assays (SPA) displayed lower sensitivity. The new available SPA are now offering better results and can represent alternative or even complementary diagnostic tools for ANA detection. The improved sensitivity of SPA technology is also changing our interpretation of the results for other types of autoantibody assays, but we need updating their calibration and new reference materials are going to be obtained in order to harmonize the assays. There is growing evidence that the identification of autoantibody combinations or profiles is helpful in improving diagnosis, patients' subgrouping and predictivity for disease evolution in the field of SARD. We report some explanatory examples to support the idea to make the use of these autoantibody profiles more and more popular. The technological evolution of the autoimmune assays is going to change our routine diagnostic laboratory tests for SARD and validation of new algorithms is needed in order to harmonize our approach to the issue.

  1. Direct-substitution method for studying second harmonic generation in arbitrary optical superlattices

    Directory of Open Access Journals (Sweden)

    Ying Chen

    Full Text Available In this paper, we present the direct-substitution (DS method to study the second-harmonic generation (SHG in arbitrary one-dimensional optical superlattices (OS. Applying this method to Fibonacci and generalized Fibonacci systems, we obtain the relative intensity of SHG and compare them with previous works. We confirmed the validity of the proposed DS method by comparing our results of SHG in quasiperiodic Fibonacci OS with previous works using analytical Fourier transform method. Furthermore, the three-dimension SHG spectra obtained by DS method present the properties of SHG in Fibonacci OS more distinctly. What’s more important, the DS method demands very few limits and can be used to compute directly and conveniently the intensity of SHG in arbitrary OS where the quasi-phase-matching (QPM can be achieved. It shows that the DS method is powerful for the calculation of electric field and intensity of SHG and can help experimentalists conveniently to estimate the distributions of SHG in any designed polarized systems. Keywords: Second-harmonic generation, Direct-substitution, Fibonacci

  2. A negative-norm least-squares method for time-harmonic Maxwell equations

    KAUST Repository

    Copeland, Dylan M.

    2012-04-01

    This paper presents and analyzes a negative-norm least-squares finite element discretization method for the dimension-reduced time-harmonic Maxwell equations in the case of axial symmetry. The reduced equations are expressed in cylindrical coordinates, and the analysis consequently involves weighted Sobolev spaces based on the degenerate radial weighting. The main theoretical results established in this work include existence and uniqueness of the continuous and discrete formulations and error estimates for simple finite element functions. Numerical experiments confirm the error estimates and efficiency of the method for piecewise constant coefficients. © 2011 Elsevier Inc.

  3. Semiconductor testing method

    International Nuclear Information System (INIS)

    Brown, Stephen.

    1992-01-01

    In a method of avoiding use of nuclear radiation, eg gamma rays, X-rays, electron beams, for testing semiconductor components for resistance to hard radiation, which hard radiation causes data corruption in some memory devices and 'latch-up' in others, similar fault effects can be achieved using a xenon or other 'light' flash gun even though the penetration of light is significantly less than that of gamma rays. The method involves treating a device with gamma radiation, measuring a particular fault current at the onset of a fault event, repeating the test with light to confirm the occurrence of the fault event at the same measured fault current, and using the fault current value as a reference for future tests using light on similar devices. (author)

  4. A review of recent advances in the spherical harmonics expansion method for semiconductor device simulation.

    Science.gov (United States)

    Rupp, K; Jungemann, C; Hong, S-M; Bina, M; Grasser, T; Jüngel, A

    The Boltzmann transport equation is commonly considered to be the best semi-classical description of carrier transport in semiconductors, providing precise information about the distribution of carriers with respect to time (one dimension), location (three dimensions), and momentum (three dimensions). However, numerical solutions for the seven-dimensional carrier distribution functions are very demanding. The most common solution approach is the stochastic Monte Carlo method, because the gigabytes of memory requirements of deterministic direct solution approaches has not been available until recently. As a remedy, the higher accuracy provided by solutions of the Boltzmann transport equation is often exchanged for lower computational expense by using simpler models based on macroscopic quantities such as carrier density and mean carrier velocity. Recent developments for the deterministic spherical harmonics expansion method have reduced the computational cost for solving the Boltzmann transport equation, enabling the computation of carrier distribution functions even for spatially three-dimensional device simulations within minutes to hours. We summarize recent progress for the spherical harmonics expansion method and show that small currents, reasonable execution times, and rare events such as low-frequency noise, which are all hard or even impossible to simulate with the established Monte Carlo method, can be handled in a straight-forward manner. The applicability of the method for important practical applications is demonstrated for noise simulation, small-signal analysis, hot-carrier degradation, and avalanche breakdown.

  5. Materials and test methods

    International Nuclear Information System (INIS)

    Kase, M.B.

    1985-01-01

    The objective of this study was to provide, in cooperation with ORNL and LANL, specimens required for studies to develop organic insulators having the cryogenic neutron irradiation resistance required for MFE systems utilizing superconducting magnetic confinement. To develop test methods and analytical procedures for assessing radiation damage. To stimulate and participate in international cooperation directed toward accomplishing these objectives. The system for producing uniaxially reinforced, 3-4 mm (0.125 in) diameter rod specimens has been refined and validated by production of excellent quality specimens using liquid-mix epoxy resin systems. The methodology is undergoing further modification to permit use of hot-melt epoxy and polyimide resin systems as will be required for the experimental program to be conducted in the NLTNIF reactor at ORNL. Preliminary studies indicate that short beam and torsional shear test methods will be useful in evaluating radiation degradation. Development of these and other applicable test methods are continuing. A cooperative program established with laboratories in Japan and in England has resulted in the production and testing of specimens having an identical configuration

  6. Waveform control method for mitigating harmonics of inverter systems with nonlinear load

    DEFF Research Database (Denmark)

    Wang, Haoran; Zhu, Guorong; Fu, Xiaobin

    2015-01-01

    instability in the DC power system, lower its efficiency, and shorten the lifetime of the DC source. This paper presents a general waveform control method that can mitigate the injection of the low-frequency ripple current by the single-phase DC/AC inverter into the DC source. It also discusses the inhibiting......DC power systems connecting to single-phase DC/AC inverters with nonlinear loads will have their DC sources being injected with AC ripple currents containing a low-frequency component at twice the output voltage frequency of the inverter and also other current harmonics. Such a current may create...

  7. Application of a modified rational harmonic balance method for a class of strongly nonlinear oscillators

    International Nuclear Information System (INIS)

    Belendez, A.; Gimeno, E.; Alvarez, M.L.; Mendez, D.I.; Hernandez, A.

    2008-01-01

    An analytical approximate technique for conservative nonlinear oscillators is proposed. This method is a modification of the rational harmonic balance method in which analytical approximate solutions have rational form. This approach gives us the frequency of the motion as a function of the amplitude of oscillation. We find that this method works very well for the whole range of parameters, and excellent agreement of the approximate frequencies with the exact one has been demonstrated and discussed. The most significant features of this method are its simplicity and its excellent accuracy for the whole range of oscillation amplitude values and the results reveal that this technique is very effective and convenient for solving conservative truly nonlinear oscillatory systems with complex nonlinearities

  8. Electric power quality analysis methods. Application to voltage dips and harmonic disturbances

    International Nuclear Information System (INIS)

    Vanya, Ignatova

    2006-10-01

    The power quality concerns all the actors in the energy domains, that they are network administrators, suppliers, producers, or consumers of electricity. The research work presented in this PhD thesis is situated in the field of the power quality monitoring. Its objective is to introduce new techniques for analysis of power quality problems. There are different methods designed for the analysis of the power quality disturbances. This method reaches very good performances in the voltage dips analysis, as it allows segmenting, classifying and characterising these power quality disturbances. The periodic systems method allows the theoretical study of the generation and the propagation of harmonic disturbances in the network. Finally, the statistical matrix method has the objective to represent statistically electrical signals without loss of important information. (author)

  9. Gravity Search Algorithm hybridized Recursive Least Square method for power system harmonic estimation

    Directory of Open Access Journals (Sweden)

    Santosh Kumar Singh

    2017-06-01

    Full Text Available This paper presents a new hybrid method based on Gravity Search Algorithm (GSA and Recursive Least Square (RLS, known as GSA-RLS, to solve the harmonic estimation problems in the case of time varying power signals in presence of different noises. GSA is based on the Newton’s law of gravity and mass interactions. In the proposed method, the searcher agents are a collection of masses that interact with each other using Newton’s laws of gravity and motion. The basic GSA algorithm strategy is combined with RLS algorithm sequentially in an adaptive way to update the unknown parameters (weights of the harmonic signal. Simulation and practical validation are made with the experimentation of the proposed algorithm with real time data obtained from a heavy paper industry. A comparative performance of the proposed algorithm is evaluated with other recently reported algorithms like, Differential Evolution (DE, Particle Swarm Optimization (PSO, Bacteria Foraging Optimization (BFO, Fuzzy-BFO (F-BFO hybridized with Least Square (LS and BFO hybridized with RLS algorithm, which reveals that the proposed GSA-RLS algorithm is the best in terms of accuracy, convergence and computational time.

  10. A novel method for producing low cost dynamometric wheels based on harmonic elimination techniques

    Science.gov (United States)

    Gutiérrez-López, María D.; García de Jalón, Javier; Cubillo, Adrián

    2015-02-01

    A method for producing low cost dynamometric wheels is presented in this paper. For carrying out this method, the metallic part of a commercial wheel is instrumented with strain gauges, which must be grouped in at least three circumferences and in equidistant radial lines. The strain signals of the same circumference are linearly combined to obtain at least two new signals that only depend on the tyre/road contact forces and moments. The influence of factors like the angle rotated by the wheel, the temperature or the centrifugal forces is eliminated in them by removing the continuous component and the largest possible number of harmonics, except the first or the second one, of the strain signals. The contact forces and moments are obtained from these new signals by solving two systems of linear equations with three unknowns each. This method is validated with some theoretical and experimental examples.

  11. Coarse-mesh rebalance methods compatible with the spherical harmonic fictitious source in neutron transport calculations

    International Nuclear Information System (INIS)

    Miller, W.F. Jr.

    1975-10-01

    The coarse-mesh rebalance method, based on neutron conservation, is used in discrete ordinates neutron transport codes to accelerate convergence of the within-group scattering source. Though very powerful for this application, the method is ineffective in accelerating the iteration on the discrete-ordinates-to-spherical-harmonics fictitious sources used for ray-effect elimination. This is largely because this source makes a minimum contribution to the neutron balance equation. The traditional rebalance approach is derived in a variational framework and compared with new rebalance approaches tailored to be compatible with the fictitious source. The new approaches are compared numerically to determine their relative advantages. It is concluded that there is little incentive to use the new methods. (3 tables, 5 figures)

  12. Harmonizing exposure metrics and methods for sustainability assessments of food contact materials

    DEFF Research Database (Denmark)

    Ernstoff, Alexi; Jolliet, Olivier; Niero, Monia

    2016-01-01

    ) and Cradle to Cradle to support packaging design. Each assessment has distinct context and goals, but can help manage exposure to toxic chemicals and other environmental impacts. Metrics a nd methods to quantify and characterize exposure to potentially toxic chemicals specifically in food packaging are......, however, notably lacking from such assessments. Furthermore, previous case studies demonstrated that sustainable packaging design focuses, such as decreasing greenhouse gas emissions or resource consumption, can increase exposure to toxic chemicals through packaging. Thereby, developing harmonized methods...... for quantifying exposure to chemicals in food packaging is critical to ensure ‘sustainable packages’ do not increase exposure to toxic chemicals. Therefore we developed modelling methods suitable for first-tier risk screening and environmental assessments. The modelling framework was based on the new product...

  13. Cluster models of light nuclei and the method of hyperspherical harmonics: Successes and challenges

    International Nuclear Information System (INIS)

    Danilin, B. V.; Shul'gina, N. B.; Ershov, S. N.; Vaagen, J. S.

    2009-01-01

    Hyperspherical-harmonics method to investigate the lightest nuclei having three-cluster structure is discussed together with recent experiments. Properties of bound states and methods to explore three-body continuum are presented. The challenges created by large neutron excess and halo phenomena are highlighted. Astrophysical aspects of the 7 Li + n → 8 Li + γ reaction and the solar-boron-neutrinos problem are analyzed. Three-cluster structure of highly excited states in 8 Be is shown to be responsible for extreme isospin mixing. Progress in studies of 6 He- and 11 Li-induced inclusive and exclusive nuclear reactions is demonstrated, providing information on the nature of continuum structures of Borromean nuclei.

  14. On period doubling bifurcations of cycles and the harmonic balance method

    International Nuclear Information System (INIS)

    Itovich, Griselda R.; Moiola, Jorge L.

    2006-01-01

    This works attempts to give quasi-analytical expressions for subharmonic solutions appearing in the vicinity of a Hopf bifurcation. Starting with well-known tools as the graphical Hopf method for recovering the periodic branch emerging from classical Hopf bifurcation, precise frequency and amplitude estimations of the limit cycle can be obtained. These results allow to attain approximations for period doubling orbits by means of harmonic balance techniques, whose accuracy is established by comparison of Floquet multipliers with continuation software packages. Setting up a few coefficients, the proposed methodology yields to approximate solutions that result from a second period doubling bifurcation of cycles and to extend the validity limits of the graphical Hopf method

  15. Modeling and Simulation of DC Power Electronics Systems Using Harmonic State Space (HSS) Method

    DEFF Research Database (Denmark)

    Kwon, Jun Bum; Wang, Xiongfei; Bak, Claus Leth

    2015-01-01

    based on the state-space averaging and generalized averaging, these also have limitations to show the same results as with the non-linear time domain simulations. This paper presents a modeling and simulation method for a large dc power electronic system by using Harmonic State Space (HSS) modeling......For the efficiency and simplicity of electric systems, the dc based power electronics systems are widely used in variety applications such as electric vehicles, ships, aircrafts and also in homes. In these systems, there could be a number of dynamic interactions between loads and other dc-dc....... Through this method, the required computation time and CPU memory for large dc power electronics systems can be reduced. Besides, the achieved results show the same results as with the non-linear time domain simulation, but with the faster simulation time which is beneficial in a large network....

  16. Determination of the most reactivity control rod by pseudo-harmonics perturbation method

    International Nuclear Information System (INIS)

    Freire, Fernando S.; Silva, Fernando C.; Martinez, Aquilino S.

    2005-01-01

    Frequently it is necessary to compute the change in core multiplication caused by a change in the core temperature or composition. Even when this perturbation is localized, such as a control rod inserted into the core, one does not have to repeat the original criticality calculation, but instead we can use the well-known pseudo-harmonics perturbation method to express the corresponding change in the multiplication factor in terms of the neutron flux expanded in the basis vectors characterizing the unperturbed core. Therefore we may compute the control rod worth to find the most reactivity control rod to calculate the fast shutdown margin. In this thesis we propose a simple and precise method to identify the most reactivity control rod. (author)

  17. Higher-order approximate solutions to the relativistic and Duffing-harmonic oscillators by modified He's homotopy methods

    International Nuclear Information System (INIS)

    Belendez, A; Pascual, C; Fernandez, E; Neipp, C; Belendez, T

    2008-01-01

    A modified He's homotopy perturbation method is used to calculate higher-order analytical approximate solutions to the relativistic and Duffing-harmonic oscillators. The He's homotopy perturbation method is modified by truncating the infinite series corresponding to the first-order approximate solution before introducing this solution in the second-order linear differential equation, and so on. We find this modified homotopy perturbation method works very well for the whole range of initial amplitudes, and the excellent agreement of the approximate frequencies and periodic solutions with the exact ones has been demonstrated and discussed. The approximate formulae obtained show excellent agreement with the exact solutions, and are valid for small as well as large amplitudes of oscillation, including the limiting cases of amplitude approaching zero and infinity. For the relativistic oscillator, only one iteration leads to high accuracy of the solutions with a maximal relative error for the approximate frequency of less than 1.6% for small and large values of oscillation amplitude, while this relative error is 0.65% for two iterations with two harmonics and as low as 0.18% when three harmonics are considered in the second approximation. For the Duffing-harmonic oscillator the relative error is as low as 0.078% when the second approximation is considered. Comparison of the result obtained using this method with those obtained by the harmonic balance methods reveals that the former is very effective and convenient

  18. CFL Labeling Harmonization in the United States, China, Brazil andELI Member Countries: Specifications, Testing, and MutualRecognition

    Energy Technology Data Exchange (ETDEWEB)

    Fridley, David; Lin, Jiang; Denver, Andrea; Biermayer, Peter; Dillavou, Tyler

    2005-07-20

    This report examines critical differences among energy-efficient labeling programs for CFLs in Brazil, China, the United States, and the seven members of the international Efficient Lighting Initiative (ELI) in terms of technical specifications and test procedures, and review issues related to international harmonization of these standards.

  19. Experimental demonstration of efficient and robust second harmonic generation using the adiabatic temperature gradient method

    Science.gov (United States)

    Dimova, E.; Steflekova, V.; Karatodorov, S.; Kyoseva, E.

    2018-03-01

    We propose a way of achieving efficient and robust second-harmonic generation. The technique proposed is similar to the adiabatic population transfer in a two-state quantum system with crossing energies. If the phase mismatching changes slowly, e.g., due to a temperature gradient along the crystal, and makes the phase match for second-harmonic generation to occur, then the energy would be converted adiabatically to the second harmonic. As an adiabatic technique, the second-harmonic generation scheme presented is stable to variations in the crystal parameters, as well as in the input light, crystal length, input intensity, wavelength and angle of incidence.

  20. Method of solution of the neutron transport equation in multidimensional cartesian geometries using spherical harmonics and spatially orthogonal polynomials

    International Nuclear Information System (INIS)

    Fenstermacher, T.E.

    1981-01-01

    The solution of the neutron transport equation has long been a subject of intense interest to nuclear engineers. Present computer codes for the solution of this equation, however, are expensive to run for large, multidimensional problems, and also suffer from computational problems such as the ray effect. A method has been developed which eliminates many of these problems. It consists of transforming the transport equation into a set of linear partial differential equations by the use of spherical harmonics. The problem volume is divided into mesh boxes, and the flux components are approximated within each mesh box by spatially orthogonal quadratic polynomials, which need not be continuous at mesh box interfaces. A variational principle is developed, and used to solve for the unknown coefficients of these polynomials. Both one dimensional and two dimensional computer codes using this method have been written. The codes have each been tested on several test cases, and the solutions checked against solutions obtained by other methods. While the codes have some difficulty in modeling sharp transients, they produce excellent results on problems where the characteristic lengths are many mean free paths. On one test case, the two dimensional code, SHOP/2D, required only one-fourth the computer time required by the finite difference, discrete ordinates code TWOTRAN to produce a solution. In addition, SHOP/2D converged much better than TWOTRAN and produced more physical-appearing results

  1. Reduction method for residual stress of welded joint using harmonic vibrational load

    International Nuclear Information System (INIS)

    Aoki, Shigeru; Nishimura, Tadashi; Hiroi, Tetsumaro; Hirai, Seiji

    2007-01-01

    Welding is widely used for construction of many structures. Since welding is a process using locally given heat, residual stress is generated near the bead. Tensile residual stress degrades fatigue strength. Some reduction methods of residual stress have been presented and, for example, heat treatment and shot peening are practically used. However, those methods need special tools and are time consuming. In this paper, a new method for reduction of residual stress using harmonic vibrational load during welding is proposed. The proposed method is examined experimentally for some conditions. Two thin plates are supported on the supporting device and butt-welded using an automatic CO 2 gas shielded arc welding machine. Residual stress in the direction of the bead is measured by using a paralleled beam X-ray diffractometer with scintillation counter after removing quenched scale chemically. First, the welding of rolled steel for general structure for some excitation frequencies is examined. Specimens are welded along the groove on both sides. For all frequencies, tensile residual stress near the bead is significantly reduced. Second, welding of the specimen made of high tensile strength steel is examined. In this case, tensile residual stress near the bead is also reduced. Finally, the proposed method is examined by an analytical method. An analytical model which consists of mass and preloaded springs with elasto-plastic characteristic is used. Reduction of residual stress is demonstrated using this model

  2. High Performance Harmonic Isolation By Means of The Single-phase Series Active Filter Employing The Waveform Reconstruction Method

    DEFF Research Database (Denmark)

    Senturk, Osman Selcuk; Hava, Ahmet M.

    2009-01-01

    current sampling delay reduction method (SDRM), a single-phase SAF compensated system provides higher harmonic isolation performance and higher stability margins compared to the system using conventional synchronous reference frame based methods. The analytical, simulation, and experimental studies of a 2...

  3. A controlled filtering method for estimating harmonics of off-nominal frequencies

    NARCIS (Netherlands)

    Marques, C.A.G.; Ribeiro, M.V.; Duque, C.A.; Ribeiro, P.F.; Da Silva, E.A.B.

    2012-01-01

    The increasing use of power electronics in power systems causes a high injection of harmonic components which can in turn interfere with utility equipment and customer loads. Therefore, the correct estimation and measurement of harmonics have become an important issue. If the power frequency of the

  4. Evaluation of the Discrepancy between the European Pharmacopoeia Test and an Adopted United States Pharmacopoeia Test Regarding the Weight Uniformity of Scored Tablet Halves: Is Harmonization Required?

    Science.gov (United States)

    Zaid, Abdel Naser; Ghoush, Abeer Abu; Al-Ramahi, Rowa'; Are'r, Mohammed

    2012-01-01

    The aim of this study was to evaluate whether there exists any discrepancy between the European Pharmacopoeia (Ph. Eur.) and adopted United States Pharmacopeia (USP) tests concerning the weight uniformity measurements of tablet halves after splitting. The USP method does not contain provisions to evaluate split tablets, so here we adopt their whole tablet weight uniformity method. Twenty-nine different commercial scored tablets (local and imported) were divided. The split units were individually weighed and the relative standard deviation (RSD) for each product was calculated and then evaluated according to both the adopted USP and the Ph. Eur. tests of weight uniformity. Twenty out of the 29 products tested failed the USP test, while 14 of them failed the Ph. Eur. test. Nine products passed both the USP and Ph. Eur. tests. Six products passed the Ph. Eur. test but failed the USP test, with all of these products having an RSD greater than 6%. The correlation coefficient between the weight and content of split halves for three randomly selected products-corotenol 100 mg, corotenol 50 mg, and lorazepam 2.5 mg-was found to be 0.986, 0.998, and 0.72, respectively. A clear difference can be seen between outcomes obtained by the two compendial tablet splitting methods with regard to weight uniformity. Results from the USP test showed that tighter measures are needed to pass the test. Our results argue that the Ph. Eur. should revise the existing weight uniformity test on scored tablets to include the RSD parameter in it. The USP should include this adopted test as a specific test for scored tablet halves, not just whole tablets. Manufacturers in some cases will need to improve the quality of the produced scored tablets in order to pass the USP test, especially those with low therapeutic indices. Finally, harmonization between the pharmacopoeias regarding the weight uniformity testing of split tablets is warranted. The aim of this study was to evaluate whether there

  5. Test system and method

    DEFF Research Database (Denmark)

    2012-01-01

    at a second distance from the centre, the second distance being larger than the first distance, one or more sensors arranged at each fluid channel, wherein the sensors each comprise at least one optical detectable member, the test apparatus further comprising one or more optical sensing devices arranged...... larger than the first distance, one or more sensors arranged at each fluid channel, wherein the sensors each comprise at least one optical detectable member, the test apparatus further comprising one or more optical sensing devices arranged for sensing the at least one optical detectable member...

  6. Beam test of a grid-less multi-harmonic buncher

    International Nuclear Information System (INIS)

    Ostroumov, P.N.; Aseev, V.N.; Barcikowski, A.; Clifft, B.; Pardo, R.; Sharamentov, S.I.; Sengupta, M.

    2008-01-01

    The Argonne Tandem Linear Accelerator System (ATLAS) is the first superconducting heavy-ion linac in the world. Currently ATLAS is being upgraded with the Californium Rare Ion Breeder Upgrade (CARIBU). The latter is a funded project to expand the range of shortlived, neutron-rich rare isotope beams available for nuclear physics research at ATLAS. To avoid beam losses associated with the existing gridded multi-harmonic buncher (MHB), we have developed and built a grid-less four-harmonic buncher with fundamental frequency of 12.125 MHz. In this paper, we report the results of the MHB commissioning and ATLAS beam performance with the new buncher.

  7. Harmonization of dosimetric information obtained by different EPR methods: Experience of the Techa river study

    Energy Technology Data Exchange (ETDEWEB)

    Volchkova, A. [Urals Research Center for Radiation Medicine, 68A, Vorovsky Str., 454076 Chelyabinsk (Russian Federation); Shishkina, E.A., E-mail: ElenaA.Shishkina@gmail.com [Urals Research Center for Radiation Medicine, 68A, Vorovsky Str., 454076 Chelyabinsk (Russian Federation); Ivanov, D. [Institute of Metal Physics, Russian Academy of Sciences, 18, S. Kovalevskoy Str., 620041 Yekaterinburg (Russian Federation); Timofeev, Yu. [Urals Research Center for Radiation Medicine, 68A, Vorovsky Str., 454076 Chelyabinsk (Russian Federation); Fattibene, P.; Della Monaca, S. [Istituto Superiore di Sanita and Istituto Nazionale di Fisica Nucleare, Viale Regina Elena 299, 00161 Rome (Italy); Wieser, A. [Helmholtz Zentrum Muenchen, German Research Centre for Environmental Health, D-85764 Neuherberg (Germany); Degteva, M.O. [Urals Research Center for Radiation Medicine, 68A, Vorovsky Str., 454076 Chelyabinsk (Russian Federation)

    2011-09-15

    Between 1949 and 1956 the Techa River (Southern Urals, Russia) was contaminated as a result of releases of radioactive waste by the Mayak Production Association. EPR dosimetry with tooth enamel has been used to estimate the external exposure of Techa riverside residents over the last 17 years. The database 'Tooth' of the Urals Research Center for Radiation Medicine (URCRM) has accumulated about 1000 EPR measurements of tooth enamel from the rural population of the Urals region. The teeth were investigated by laboratories of Russia, USA, Germany and Italy. Most of the enamel samples were measured several times in different laboratories. Each laboratory used different equipment and its own methods for sample preparation and EPR spectra analysis. Even measurements performed at the same laboratory over 10-15 years may not be assumed as uniform: methods change with time, and equipment is subject to aging. These two factors influenced EPR performance. The purpose of this study is, therefore, the harmonization of EPR data accumulated during long-term dosimetric investigations in the Southern Urals for further pooled analysis. The results will be used for external dose evaluation in the Techa River region.

  8. A simplified spherical harmonic method for coupled electron-photon transport calculations

    International Nuclear Information System (INIS)

    Josef, J.A.

    1996-12-01

    In this thesis we have developed a simplified spherical harmonic method (SP N method) and associated efficient solution techniques for 2-D multigroup electron-photon transport calculations. The SP N method has never before been applied to charged-particle transport. We have performed a first time Fourier analysis of the source iteration scheme and the P 1 diffusion synthetic acceleration (DSA) scheme applied to the 2-D SP N equations. Our theoretical analyses indicate that the source iteration and P 1 DSA schemes are as effective for the 2-D SP N equations as for the 1-D S N equations. Previous analyses have indicated that the P 1 DSA scheme is unstable (with sufficiently forward-peaked scattering and sufficiently small absorption) for the 2-D S N equations, yet is very effective for the 1-D S N equations. In addition, we have applied an angular multigrid acceleration scheme, and computationally demonstrated that it performs as well for the 2-D SP N equations as for the 1-D S N equations. It has previously been shown for 1-D S N calculations that this scheme is much more effective than the DSA scheme when scattering is highly forward-peaked. We have investigated the applicability of the SP N approximation to two different physical classes of problems: satellite electronics shielding from geomagnetically trapped electrons, and electron beam problems. In the space shielding study, the SP N method produced solutions that are accurate within 10% of the benchmark Monte Carlo solutions, and often orders of magnitude faster than Monte Carlo. We have successfully modeled quasi-void problems and have obtained excellent agreement with Monte Carlo. We have observed that the SP N method appears to be too diffusive an approximation for beam problems. This result, however, is in agreement with theoretical expectations

  9. An explicit approximate solution to the Duffing-harmonic oscillator by a cubication method

    International Nuclear Information System (INIS)

    Belendez, A.; Mendez, D.I.; Fernandez, E.; Marini, S.; Pascual, I.

    2009-01-01

    The nonlinear oscillations of a Duffing-harmonic oscillator are investigated by an approximated method based on the 'cubication' of the initial nonlinear differential equation. In this cubication method the restoring force is expanded in Chebyshev polynomials and the original nonlinear differential equation is approximated by a Duffing equation in which the coefficients for the linear and cubic terms depend on the initial amplitude, A. The replacement of the original nonlinear equation by an approximate Duffing equation allows us to obtain explicit approximate formulas for the frequency and the solution as a function of the complete elliptic integral of the first kind and the Jacobi elliptic function, respectively. These explicit formulas are valid for all values of the initial amplitude and we conclude this cubication method works very well for the whole range of initial amplitudes. Excellent agreement of the approximate frequencies and periodic solutions with the exact ones is demonstrated and discussed and the relative error for the approximate frequency is as low as 0.071%. Unlike other approximate methods applied to this oscillator, which are not capable to reproduce exactly the behaviour of the approximate frequency when A tends to zero, the cubication method used in this Letter predicts exactly the behaviour of the approximate frequency not only when A tends to infinity, but also when A tends to zero. Finally, a closed-form expression for the approximate frequency is obtained in terms of elementary functions. To do this, the relationship between the complete elliptic integral of the first kind and the arithmetic-geometric mean as well as Legendre's formula to approximately obtain this mean are used.

  10. Harmonization of rules for VCU testing of maize in comparable agro ecological regions

    Directory of Open Access Journals (Sweden)

    van Waes J.

    2004-01-01

    variety with the same reliability as at national level. For the future variety testing should be realized on the basis of comparable agro-ecological regions with the same crop husbandry and use of the crop. These regions must be clearly defined so that the release of varieties corresponds to the high demands for harvest security and good conservation possibilities of the harvested material. The most important criteria for evaluation should be: harvest security, disease resistance, yield and quality. The basis for a good success for international cooperation is a good knowledge of the national systems: searching for similarities and finding a solution for differences. Once a variety on a catalogue in one European country, the breeding company tries to sell the variety in the whole agro-ecological for which the variety is adapted. Therefore it is important that in the surrounding zones, where the variety is tested, the same criteria are valid. In this presentation we will give a proposal for harmonization and international cooperation for controlling the VCU- value of new maize varieties.

  11. Solution of multigroup transport equation in x-y-z geometry by the spherical harmonics method using finite Fourier transformation

    International Nuclear Information System (INIS)

    Kobayashi, Keisuke; Kikuchi, Hirohiko; Tsutsuguchi, Ken

    1993-01-01

    A neutron multigroup transport equation in x-y-z geometry is solved by the spherical harmonics method using finite Fourier transformation. Using the first term of the Fourier series for the space variables of spherical harmonics moments, three-point finite difference like equations are derived for x-, y- and z-axis directions, which are more consistent and accurate than those derived using the usual finite difference approximation, and these equations are solved by the iteration method in each axis direction alternatively. A method to find an optimum acceleration factor for this inner iteration is described. It is shown in the numerical examples that the present method gives higher accuracy with less mesh points that the usual finite difference method. (author)

  12. Harmonization of malaria rapid diagnostic tests: best practices in labelling including instructions for use.

    Science.gov (United States)

    Jacobs, Jan; Barbé, Barbara; Gillet, Philippe; Aidoo, Michael; Serra-Casas, Elisa; Van Erps, Jan; Daviaud, Joelle; Incardona, Sandra; Cunningham, Jane; Visser, Theodoor

    2014-12-17

    Rapid diagnostic tests (RDTs) largely account for the scale-up of malaria diagnosis in endemic settings. However, diversity in labelling including the instructions for use (IFU) limits their interchangeability and user-friendliness. Uniform, easy to follow and consistent labelling, aligned with international standards and appropriate for the level of the end user's education and training, is crucial but a consolidated resource of information regarding best practices for IFU and labelling of RDT devices, packaging and accessories is not available. The Roll Back Malaria Partnership (RBM) commissioned the compilation of international standards and regulatory documents and published literature containing specifications and/or recommendations for RDT design, packaging and labelling of in vitro diagnostics (IVD) (which includes RDTs), complemented with a questionnaire based survey of RDT manufacturers and implementers. A summary of desirable RDT labelling characteristics was compiled, which was reviewed and discussed during a RBM Stakeholder consultation meeting and subsequently amended and refined by a dedicated task force consisting of country programme implementers, experts in RDT implementation, IVD regulatory experts and manufacturers. This process led to the development of consensus documents with a list of suggested terms and abbreviations as well as specifications for labelling of box, device packaging, cassettes, buffer bottle and accessories (lancets, alcohol swabs, transfer devices, desiccants). Emphasis was placed on durability (permanent printing or water-resistant labels), legibility (font size, letter type), comprehension (use of symbols) and ease of reference (e.g. place of labelling on the box or cassette packaging allowing quick oversight). A generic IFU template was developed, comprising background information, a template for procedure and reading/interpretation, a selection of appropriate references and a symbol key of internationally recognized

  13. Standardized waste form test methods

    International Nuclear Information System (INIS)

    Slate, S.C.

    1984-11-01

    The Materials Characterization Center (MCC) is developing standard tests to characterize nuclear waste forms. Development of the first thirteen tests was originally initiated to provide data to compare different high-level waste (HLW) forms and to characterize their basic performance. The current status of the first thirteen MCC tests and some sample test results is presented: The radiation stability tests (MCC-6 and 12) and the tensile-strength test (MCC-11) are approved; the static leach tests (MCC-1, 2, and 3) are being reviewed for full approval; the thermal stability (MCC-7) and microstructure evaluation (MCC-13) methods are being considered for the first time; and the flowing leach tests methods (MCC-4 and 5), the gas generation methods (MCC-8 and 9), and the brittle fracture method (MCC-10) are indefinitely delayed. Sample static leach test data on the ARM-1 approved reference material are presented. Established tests and proposed new tests will be used to meet new testing needs. For waste form production, tests on stability and composition measurement are needed to provide data to ensure waste form quality. In transportation, data are needed to evaluate the effects of accidents on canisterized waste forms. The new MCC-15 accident test method and some data are presented. Compliance testing needs required by the recent draft repository waste acceptance specifications are described. These specifications will control waste form contents, processing, and performance. 2 references, 2 figures

  14. Standardized waste form test methods

    International Nuclear Information System (INIS)

    Slate, S.C.

    1984-01-01

    The Materials Characterization Center (MCC) is developing standard tests to characterize nuclear waste forms. Development of the first thirteen tests was originally initiated to provide data to compare different high-level waste (HLW) forms and to characterize their basic performance. The current status of the first thirteen MCC tests and some sample test results are presented: the radiation stability tests (MCC-6 and 12) and the tensile-strength test (MCC-11) are approved; the static leach tests (MCC-1, 2, and 3) are being reviewed for full approval; the thermal stability (MCC-7) and microstructure evaluation (MCC-13) methods are being considered for the first time; and the flowing leach test methods (MCC-4 and 5), the gas generation methods (MCC-8 and 9), and the brittle fracture method (MCC-10) are indefinitely delayed. Sample static leach test data on the ARM-1 approved reference material are presented. Established tests and proposed new tests will be used to meet new testing needs. For waste form production, tests on stability and composition measurement are needed to provide data to ensure waste form quality. In transporation, data are needed to evaluate the effects of accidents on canisterized waste forms. The new MCC-15 accident test method and some data are presented. Compliance testing needs required by the recent draft repository waste acceptance specifications are described. These specifications will control waste form contents, processing, and performance

  15. Development of Gravity Acceleration Measurement Using Simple Harmonic Motion Pendulum Method Based on Digital Technology and Photogate Sensor

    Science.gov (United States)

    Yulkifli; Afandi, Zurian; Yohandri

    2018-04-01

    Development of gravitation acceleration measurement using simple harmonic motion pendulum method, digital technology and photogate sensor has been done. Digital technology is more practical and optimizes the time of experimentation. The pendulum method is a method of calculating the acceleration of gravity using a solid ball that connected to a rope attached to a stative pole. The pendulum is swung at a small angle resulted a simple harmonic motion. The measurement system consists of a power supply, Photogate sensors, Arduino pro mini and seven segments. The Arduino pro mini receives digital data from the photogate sensor and processes the digital data into the timing data of the pendulum oscillation. The calculation result of the pendulum oscillation time is displayed on seven segments. Based on measured data, the accuracy and precision of the experiment system are 98.76% and 99.81%, respectively. Based on experiment data, the system can be operated in physics experiment especially in determination of the gravity acceleration.

  16. Application of transfer function based harmonic study method to an offshore wind farm

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yu; Bollen, Math [STRI AB, Gothenburg (Sweden); Martins, Marcia [Alstom Wind, Barcelona (Spain)

    2012-07-01

    This paper presents the results from a harmonic study for a planned offshore wind farm with 252 MW installed capacity. Both the collection grid and the public grid are modelled in detail using Powerfactory. Both primary emission from wind turbines and secondary emission due to the distortion in the public grid are studied. Besides, due to the presence of HVDC platform and another two wind farms, details of which are not known at the moment, a sensitivity analysis is conducted to investigate the potential influence on the harmonic emission. (orig.)

  17. A New Method for Estimating the Number of Harmonic Components in Noise with Application in High Resolution Radar

    Directory of Open Access Journals (Sweden)

    Radoi Emanuel

    2004-01-01

    Full Text Available In order to operate properly, the superresolution methods based on orthogonal subspace decomposition, such as multiple signal classification (MUSIC or estimation of signal parameters by rotational invariance techniques (ESPRIT, need accurate estimation of the signal subspace dimension, that is, of the number of harmonic components that are superimposed and corrupted by noise. This estimation is particularly difficult when the S/N ratio is low and the statistical properties of the noise are unknown. Moreover, in some applications such as radar imagery, it is very important to avoid underestimation of the number of harmonic components which are associated to the target scattering centers. In this paper, we propose an effective method for the estimation of the signal subspace dimension which is able to operate against colored noise with performances superior to those exhibited by the classical information theoretic criteria of Akaike and Rissanen. The capabilities of the new method are demonstrated through computer simulations and it is proved that compared to three other methods it carries out the best trade-off from four points of view, S/N ratio in white noise, frequency band of colored noise, dynamic range of the harmonic component amplitudes, and computing time.

  18. Comparative Evaluation of Modeling Methods for Harmonic Stability Analysis of Three-Phase Voltage Source Converters

    DEFF Research Database (Denmark)

    Kwon, Jun Bum; Wang, Xiongfei; Bak, Claus Leth

    2015-01-01

    As the increasing of power electronics based systems, not only the component-based analysis but also a systematic interaction analysis with each other systems are being important. Especially studies about the stability and the harmonics interaction are critical in order to establish the required ...

  19. Application of the first approximation of the K-harmonics method to the O+ states of 16O

    International Nuclear Information System (INIS)

    Alcaras, J.A.C.; Silveira, H.V. da.

    1977-01-01

    The energy levels of the O + states, the charge form factor and the root mean square charge radius of the 16 O were calculated in the first approximation of the K-harmonics method. The calculation were done for six different potentials. The results obtained for the ground state energy, charge form factor and rms charge radius are in agreement with the experimental results, but this is not the case for the energies of the O + excited states

  20. Application of the first approximation of the K-harmonics method to the O+ states of 16O

    International Nuclear Information System (INIS)

    Silveira, H.V. da.

    1977-01-01

    The first (also called basic) approximation of the K-harmonics method is applied to the nucleus of 16 O taken as a system of 8 protons and 8 neutrons interacting through nuclear and coulomb two-body potentials, in order to obtain the spectrum of the O + states of 16 O, and also the charge form factor and the root mean square charge radius [pt

  1. The Tanzania experience: clinical laboratory testing harmonization and equipment standardization at different levels of a tiered health laboratory system.

    Science.gov (United States)

    Massambu, Charles; Mwangi, Christina

    2009-06-01

    The rapid scale-up of the care and treatment programs in Tanzania during the preceding 4 years has greatly increased the demand for quality laboratory services for diagnosis of HIV and monitoring patients during antiretroviral therapy. Laboratory services were not in a position to cope with this demand owing to poor infrastructure, lack of human resources, erratic and/or lack of reagent supply and commodities, and slow manual technologies. With the limited human resources in the laboratory and the need for scaling up the care and treatment program, it became necessary to install automated equipment and train personnel for the increased volume of testing and new tests across all laboratory levels. With the numerous partners procuring equipment, the possibility of a multitude of equipment platforms with attendant challenges for procurement of reagents, maintenance of equipment, and quality assurance arose. Tanzania, therefore, had to harmonize laboratory tests and standardize laboratory equipment at different levels of the laboratory network. The process of harmonization of tests and standardization of equipment included assessment of laboratories, review of guidelines, development of a national laboratory operational plan, and stakeholder advocacy. This document outlines this process.

  2. Analysis of Dynamical Characteristic of Piecewise-Nonlinear Asymmetric Hysteretic System Based on Incremental Harmonic Balance Method

    Directory of Open Access Journals (Sweden)

    H. R. Liu

    2015-01-01

    Full Text Available Considering a sort of elastic mass with asymmetric hysteresis characteristic which widespread existing in engineering field, a piecewise-nonlinear dynamical equation, which contains asymmetric hysteretic loop, is established. By using the method of Incremental Harmonic Balance (IHB, the analytic linearized algebraic equation of the system is obtained. On the basis of this algebraic equation, the coefficients of the algebraic expression are figured out by the incremental procedure and the iterative process of the regulated variable. Through the emulation, the amplitude frequency response curve and the relation between the value of the harmonic component and the external excitation are researched; the bistable regions of the bifurcation diagram of the system under the variation of the excitation amplitude are studied. The above results can be used to guide the research of the asymmetric hysteretic system with polynomial expression.

  3. Standard Test Method for Sandwich Corrosion Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method defines the procedure for evaluating the corrosivity of aircraft maintenance chemicals, when present between faying surfaces (sandwich) of aluminum alloys commonly used for aircraft structures. This test method is intended to be used in the qualification and approval of compounds employed in aircraft maintenance operations. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements appear in Section 9.

  4. Data Collection and Harmonization in HIV Research: The Seek, Test, Treat, and Retain Initiative at the National Institute on Drug Abuse.

    Science.gov (United States)

    Chandler, Redonna K; Kahana, Shoshana Y; Fletcher, Bennett; Jones, Dionne; Finger, Matthew S; Aklin, Will M; Hamill, Kathleen; Webb, Candace

    2015-12-01

    Large-scale, multisite data sets offer the potential for exploring the public health benefits of biomedical interventions. Data harmonization is an emerging strategy to increase the comparability of research data collected across independent studies, enabling research questions to be addressed beyond the capacity of any individual study. The National Institute on Drug Abuse recently implemented this novel strategy to prospectively collect and harmonize data across 22 independent research studies developing and empirically testing interventions to effectively deliver an HIV continuum of care to diverse drug-abusing populations. We describe this data collection and harmonization effort, collectively known as the Seek, Test, Treat, and Retain Data Collection and Harmonization Initiative, which can serve as a model applicable to other research endeavors.

  5. CALCULATION METHOD OF ELECTRIC POWER LINES MAGNETIC FIELD STRENGTH BASED ON CYLINDRICAL SPATIAL HARMONICS

    Directory of Open Access Journals (Sweden)

    A.V. Erisov

    2016-05-01

    Full Text Available Purpose. Simplification of accounting ratio to determine the magnetic field strength of electric power lines, and assessment of their environmental safety. Methodology. Description of the transmission lines of the magnetic field by using techniques of spatial harmonic analysis in the cylindrical coordinate system is carried out. Results. For engineering calculations of electric power lines magnetic field with sufficient accuracy describes their first spatial harmonic magnetic field. Originality. Substantial simplification of the definition of the impact of the construction of transmission line poles on the value of its magnetic field and the bands of land alienation sizes. Practical value. The environmentally friendly projection electric power lines on the level of the magnetic field.

  6. Methods for Equating Mental Tests.

    Science.gov (United States)

    1984-11-01

    1983) compared conventional and IRT methods for equating the Test of English as a Foreign Language ( TOEFL ) after chaining. Three conventional and...three IRT equating methods were examined in this study; two sections of TOEFL were each (separately) equated. The IRT methods included the following: (a...group. A separate base form was established for each of the six equating methods. Instead of equating the base-form TOEFL to itself, the last (eighth

  7. PARATHYROID HORMONE VALUES IN THYROID GLAND SURGERIES BY HARMONIC SCALPEL AND BY CONVENTIONAL METHODS

    OpenAIRE

    Grabovac, Stjepan; Prgomet, Drago; Janjanin, Saša; Đanić Hadžibegović, Ana

    2013-01-01

    We have examined if there are any differences in intraoperative and early postoperative concentrations of parathyroid hormone between the first group of patients, who had thyroidectomy surgery performed by harmonic scalpel, and the second group of patients operated on by standard techniqes with the use of electrocoagulation and ligature as primary hemostatic procedures. All the patients having total thyroidectomy had their blood taken in four measurement points; immediately after the inductio...

  8. Estimation and reduction of harmonic currents from power converters

    DEFF Research Database (Denmark)

    Asiminoaei, Lucian

    -based method depends very much on the amount and accuracy of collected data in the development stage. The outcome of this investigation is a Harmonic Calculation Software compiled into a Graphical User Interface PC-software application, which can be applied for fast estimations of the harmonic currents...... control of the proposed topologies are given together with laboratory tests. One harmonic current mitigation solution found is to connect (two) smaller power APF's in parallel, sharing the same ac- and dc-bus. It is proven that parallel APF's may have lower passive components although other issues arises......, like circulation currents, which is removed here by common mode coils. Another harmonic solution is to use cascade connection of (two) independent APF's that cooperatively share the task of the harmonic mitigation. Two cooperative control methods are proposed called load-sharing and harmonic-sharing...

  9. Surface harmonics method for two-dimensional time-dependent neutron transport problems of square-lattice nuclear reactors

    Energy Technology Data Exchange (ETDEWEB)

    Boyarinov, V. F.; Kondrushin, A. E.; Fomichenko, P. A. [National Research Centre Kurchatov Institute, Kurchatov Sq. 1, Moscow (Russian Federation)

    2013-07-01

    Time-dependent equations of the Surface Harmonics Method (SHM) have been derived from the time-dependent neutron transport equation with explicit representation of delayed neutrons for solving the two-dimensional time-dependent problems. These equations have been realized in the SUHAM-TD code. The TWIGL benchmark problem has been used for verification of the SUHAM-TD code. The results of the study showed that computational costs required to achieve necessary accuracy of the solution can be an order of magnitude less than with the use of the conventional finite difference method (FDM). (authors)

  10. High order harmonic generation in rare gases

    Energy Technology Data Exchange (ETDEWEB)

    Budil, Kimberly Susan [Univ. of California, Davis, CA (United States)

    1994-05-01

    The process of high order harmonic generation in atomic gases has shown great promise as a method of generating extremely short wavelength radiation, extending far into the extreme ultraviolet (XUV). The process is conceptually simple. A very intense laser pulse (I ~1013-1014 W/cm2) is focused into a dense (~1017 particles/cm3) atomic medium, causing the atoms to become polarized. These atomic dipoles are then coherently driven by the laser field and begin to radiate at odd harmonics of the laser field. This dissertation is a study of both the physical mechanism of harmonic generation as well as its development as a source of coherent XUV radiation. Recently, a semiclassical theory has been proposed which provides a simple, intuitive description of harmonic generation. In this picture the process is treated in two steps. The atom ionizes via tunneling after which its classical motion in the laser field is studied. Electron trajectories which return to the vicinity of the nucleus may recombine and emit a harmonic photon, while those which do not return will ionize. An experiment was performed to test the validity of this model wherein the trajectory of the electron as it orbits the nucleus or ion core is perturbed by driving the process with elliptically, rather than linearly, polarized laser radiation. The semiclassical theory predicts a rapid turn-off of harmonic production as the ellipticity of the driving field is increased. This decrease in harmonic production is observed experimentally and a simple quantum mechanical theory is used to model the data. The second major focus of this work was on development of the harmonic "source". A series of experiments were performed examining the spatial profiles of the harmonics. The quality of the spatial profile is crucial if the harmonics are to be used as the source for experiments, particularly if they must be refocused.

  11. Test equating methods and practices

    CERN Document Server

    Kolen, Michael J

    1995-01-01

    In recent years, many researchers in the psychology and statistical communities have paid increasing attention to test equating as issues of using multiple test forms have arisen and in response to criticisms of traditional testing techniques This book provides a practically oriented introduction to test equating which both discusses the most frequently used equating methodologies and covers many of the practical issues involved The main themes are - the purpose of equating - distinguishing between equating and related methodologies - the importance of test equating to test development and quality control - the differences between equating properties, equating designs, and equating methods - equating error, and the underlying statistical assumptions for equating The authors are acknowledged experts in the field, and the book is based on numerous courses and seminars they have presented As a result, educators, psychometricians, professionals in measurement, statisticians, and students coming to the subject for...

  12. Identification of atypical Aeromonas salmonicida : Inter-laboratory evaluation and harmonization of methods

    DEFF Research Database (Denmark)

    Dalsgaard, Inger; Gudmundsdottir, B.K.; Helgason, S.

    1998-01-01

    the biochemical identification of atypical Aer. salmonicida before and after standardization of media and methods. Five laboratories examined 25 isolates of Aer. salmonicida from diverse fish species and geographical locations including the reference strains of Aer. salmonicida subsp, salmonicida (NCMB 1102......) and Aer. salmonicida subsp. achromogenes (NCMB 1110), Without standardization of the methods, 100% agreement was obtained only for two tests: motility and ornithine decarboxylase. The main reason for the discrepancies found was the variation of the incubation time prior to reading the biochemical...

  13. Preliminary tests of a second harmonic rf system for the intense pulsed neutron source synchrotron

    International Nuclear Information System (INIS)

    Norem, J.; Brandeberry, F.

    1983-01-01

    The Rapid Cycling Synchrotron (RCS) of the Intense Pulsed Neutron Source (IPNS) operating at Argonne National Laboratory is presently producing intensities of 2 to 2.5 x 10 12 protons per pulse (ppp) with the addition of a new ion source. This intensity is close to the space charge limit of the machine, estimated at approx. 3 x 10 12 ppp, depending somewhat on the available aperture. Accelerator improvements are being directed at (1) increasing beam intensities for neutron science, (2) lowering acceleration losses to minimize activation, and (3) gaining better control of the beam so that losses can be made to occur when and where they can be most easily controlled. We are now proposing a third cavity for the RF system which would provide control of the longitudinal bunch shape during the cycle which would permit raising the effective space charge limit of the accelerator and reducing losses by providing more RF voltage at maximum acceleration. This paper presents an outline of the expected benefits together with recent results obtained during low energy operation with one of the two existing cavities operating at the second harmonic

  14. The implementation of a simplified spherical harmonics semi-analytic nodal method in PANTHER

    International Nuclear Information System (INIS)

    Hall, S.K.; Eaton, M.D.; Knight, M.P.

    2013-01-01

    Highlights: ► An SP N nodal method is proposed. ► Consistent CMFD derived and tested. ► Mark vacuum boundary conditions applied. ► Benchmarked against other diffusions and transport codes. - Abstract: In this paper an SP N nodal method is proposed which can utilise existing multi-group neutron diffusion solvers to obtain the solution. The semi-analytic nodal method is used in conjunction with a coarse mesh finite difference (CMFD) scheme to solve the resulting set of equations. This is compared against various nuclear benchmarks to show that the method is capable of computing an accurate solution for practical cases. A few different CMFD formulations are implemented and their performance compared. It is found that the effective diffusion coefficent (EDC) can provide additional stability and require less power iterations on a coarse mesh. A re-arrangement of the EDC is proposed that allows the iteration matrix to be computed at the beginning of a calculation. Successive nodal updates only modify the source term unlike existing CMFD methods which update the iteration matrix. A set of Mark vacuum boundary conditions are also derived which can be applied to the SP N nodal method extending its validity. This is possible due to a similarity transformation of the angular coupling matrix, which is used when applying the nodal method. It is found that the Marshak vacuum condition can also be derived, but would require the significant modification of existing neutron diffusion codes to implement it

  15. 77 FR 9859 - Lifesaving Equipment: Production Testing and Harmonization With International Standards

    Science.gov (United States)

    2012-02-21

    ... Prototype testing.... Manufacturers must obtain Units with rated All tests use the Units with rated (160.151... Liferafts Prototype testing.... Existing Certificates of No cost or benefit as All tests use the Costs of... designs, overseeing prototype construction, witnessing prototype testing, and monitoring production of the...

  16. Methods for testing transport models

    International Nuclear Information System (INIS)

    Singer, C.; Cox, D.

    1991-01-01

    Substantial progress has been made over the past year on six aspects of the work supported by this grant. As a result, we have in hand for the first time a fairly complete set of transport models and improved statistical methods for testing them against large databases. We also have initial results of such tests. These results indicate that careful application of presently available transport theories can reasonably well produce a remarkably wide variety of tokamak data

  17. [Inappropriate test methods in allergy].

    Science.gov (United States)

    Kleine-Tebbe, J; Herold, D A

    2010-11-01

    Inappropriate test methods are increasingly utilized to diagnose allergy. They fall into two categories: I. Tests with obscure theoretical basis, missing validity and lacking reproducibility, such as bioresonance, electroacupuncture, applied kinesiology and the ALCAT-test. These methods lack both the technical and clinical validation needed to justify their use. II. Tests with real data, but misleading interpretation: Detection of IgG or IgG4-antibodies or lymphocyte proliferation tests to foods do not allow to separate healthy from diseased subjects, neither in case of food intolerance, allergy or other diagnoses. The absence of diagnostic specificity induces many false positive findings in healthy subjects. As a result unjustified diets might limit quality of life and lead to malnutrition. Proliferation of lymphocytes in response to foods can show elevated rates in patients with allergies. These values do not allow individual diagnosis of hypersensitivity due to their broad variation. Successful internet marketing, infiltration of academic programs and superficial reporting by the media promote the popularity of unqualified diagnostic tests; also in allergy. Therefore, critical observation and quick analysis of and clear comments to unqualified methods by the scientific medical societies are more important than ever.

  18. Fluorescent penetration crack testing method

    International Nuclear Information System (INIS)

    Roth, A.

    1979-01-01

    The same cleaning, penetration, washing, development and evaluation agents are used in this method as for known methods. In order to accelerate or shorten the testing, the drying process is performed only to optical dryness of the material surface by blowing on it with pressurized air, the development by simple pressing into or dusting of the material with the developer and the temperature of the washing water is selected within room temperature range. (RW) [de

  19. Non-traditional method-based solution for elimination of lower order harmonics in voltage source inverter feeding an induction motor drive

    Directory of Open Access Journals (Sweden)

    Vargese Jegathesan

    2008-01-01

    Full Text Available This paper presents an efficient and reliable Genetic Algorithm-based solution for Specific Harmonic Elimination (SHE switching pattern. This method eliminates considerable amount of lower order line voltage harmonics in Pulse Width Modulation (PWM inverter. The determination of pulse pattern for the elimination of some lower order harmonics of a PWM inverter necessitates solving a system of nonlinear transcendental equations. Genetic Algorithm is used to solve nonlinear transcendental equations for PWM-SHE. In this proposed method, harmonics up to 17th are eliminated using Genetic Algorithm without using Dual transformer. Simulations using Matlab 7.0 and PSIM 6.1 are carried out so as to validate the solution.

  20. Extended Finite Element Method with Simplified Spherical Harmonics Approximation for the Forward Model of Optical Molecular Imaging

    Directory of Open Access Journals (Sweden)

    Wei Li

    2012-01-01

    Full Text Available An extended finite element method (XFEM for the forward model of 3D optical molecular imaging is developed with simplified spherical harmonics approximation (SPN. In XFEM scheme of SPN equations, the signed distance function is employed to accurately represent the internal tissue boundary, and then it is used to construct the enriched basis function of the finite element scheme. Therefore, the finite element calculation can be carried out without the time-consuming internal boundary mesh generation. Moreover, the required overly fine mesh conforming to the complex tissue boundary which leads to excess time cost can be avoided. XFEM conveniences its application to tissues with complex internal structure and improves the computational efficiency. Phantom and digital mouse experiments were carried out to validate the efficiency of the proposed method. Compared with standard finite element method and classical Monte Carlo (MC method, the validation results show the merits and potential of the XFEM for optical imaging.

  1. Numerical evolutions of fields on the 2-sphere using a spectral method based on spin-weighted spherical harmonics

    International Nuclear Information System (INIS)

    Beyer, Florian; Daszuta, Boris; Frauendiener, Jörg; Whale, Ben

    2014-01-01

    Many applications in science call for the numerical simulation of systems on manifolds with spherical topology. Through the use of integer spin-weighted spherical harmonics, we present a method which allows for the implementation of arbitrary tensorial evolution equations. Our method combines two numerical techniques that were originally developed with different applications in mind. The first is Huffenberger and Wandelt’s spectral decomposition algorithm to perform the mapping from physical to spectral space. The second is the application of Luscombe and Luban’s method, to convert numerically divergent linear recursions into stable nonlinear recursions, to the calculation of reduced Wigner d-functions. We give a detailed discussion of the theory and numerical implementation of our algorithm. The properties of our method are investigated by solving the scalar and vectorial advection equation on the sphere, as well as the 2 + 1 Maxwell equations on a deformed sphere. (paper)

  2. Harmonic statistics

    Energy Technology Data Exchange (ETDEWEB)

    Eliazar, Iddo, E-mail: eliazar@post.tau.ac.il

    2017-05-15

    The exponential, the normal, and the Poisson statistical laws are of major importance due to their universality. Harmonic statistics are as universal as the three aforementioned laws, but yet they fall short in their ‘public relations’ for the following reason: the full scope of harmonic statistics cannot be described in terms of a statistical law. In this paper we describe harmonic statistics, in their full scope, via an object termed harmonic Poisson process: a Poisson process, over the positive half-line, with a harmonic intensity. The paper reviews the harmonic Poisson process, investigates its properties, and presents the connections of this object to an assortment of topics: uniform statistics, scale invariance, random multiplicative perturbations, Pareto and inverse-Pareto statistics, exponential growth and exponential decay, power-law renormalization, convergence and domains of attraction, the Langevin equation, diffusions, Benford’s law, and 1/f noise. - Highlights: • Harmonic statistics are described and reviewed in detail. • Connections to various statistical laws are established. • Connections to perturbation, renormalization and dynamics are established.

  3. Harmonic statistics

    International Nuclear Information System (INIS)

    Eliazar, Iddo

    2017-01-01

    The exponential, the normal, and the Poisson statistical laws are of major importance due to their universality. Harmonic statistics are as universal as the three aforementioned laws, but yet they fall short in their ‘public relations’ for the following reason: the full scope of harmonic statistics cannot be described in terms of a statistical law. In this paper we describe harmonic statistics, in their full scope, via an object termed harmonic Poisson process: a Poisson process, over the positive half-line, with a harmonic intensity. The paper reviews the harmonic Poisson process, investigates its properties, and presents the connections of this object to an assortment of topics: uniform statistics, scale invariance, random multiplicative perturbations, Pareto and inverse-Pareto statistics, exponential growth and exponential decay, power-law renormalization, convergence and domains of attraction, the Langevin equation, diffusions, Benford’s law, and 1/f noise. - Highlights: • Harmonic statistics are described and reviewed in detail. • Connections to various statistical laws are established. • Connections to perturbation, renormalization and dynamics are established.

  4. A method for solving the spherical harmonics equations applied for space-energy transport of fast and resonance neutrons

    International Nuclear Information System (INIS)

    Matausek, M.

    1972-01-01

    A new proposed method for solving the space-energy dependent spherical harmonics equations represents a methodological contribution to neutron transport theory. The proposed method was applied for solving the problem of spec-energy transport of fast and resonance neutrons in multi-zone, cylindrical y symmetric infinite reactor cell and is related to previously developed procedure for treating the thermal energy region. The advantages of this method are as follows: a unique algorithm was obtained for detailed determination of spatial and energy distribution of neutrons (from thermal to fast) in the reactor cell; these detailed distributions enable more precise calculations of criticality conditions, obtaining adequate multigroup data and better interpretation of experimental data; computing time is rather short

  5. A pretandem harmonic buncher

    International Nuclear Information System (INIS)

    Lin, Qui-xun; Van Wechel, T.D.

    1987-01-01

    A single gap harmonic buncher has been constructed as a pretandem buncher. Over 85% of a proton dc beam has been bunched into pulses. The width (fwhm) of the pulses is 0.7 ns. The buncher is based on that built at Argonne. Changes were made to the buncher's configuration so that the buncher could be tuned to the desired four harmonic frequencies. A method of calibrating and setting the relative phases and amplitudes of the four harmonic frequencies has been used to obtain an optimum sawtooth-like bunching waveform

  6. Atto second high harmonic sources

    International Nuclear Information System (INIS)

    Nam, Chang Hee

    2008-01-01

    High harmonic generation is a powerful method to produce attosecond pulses. The high harmonics, emitted from atoms driven by intense femtosecond laser pulses, can from an attosecond pulse train with equally spaced harmonic spectrum or an isolated single attosecond pulse with broad continuum spectrum. Using high power femtosecond laser technology developed at CXRC, we have investigated the spectral and temporal characteristics of high harmonics obtained from gaseous atoms. The spectral structure of harmonics could be manipulated by controlling laser chirp, and continuous tuning of harmonic wavelengths was achieved. For rigorous temporal characterization of attosecond harmonic pulses a cross correlation technique was applied to the photoionization process by harmonic and IR femtosecond pulses and achieved the complete temporal reconstruction of attosecond pulse trains, revealing the detailed temporal structure of the attosecond chirp by material dispersion. The duration of attosecond high harmonic pulses is usually much longer than that of transform limited pulses due to the inherent chirp originating from the harmonic generation process. The attosecond chirp compensation in the harmonic generation medium itself was demonstrated, thereby realizing the generation of near transform limited attosecond pulses. The interference of attosecond electron wave packets, generated from an atom by attosecond harmonic pulses, will be also presented

  7. Verification of the coupled space-angle adaptivity algorithm for the finite element-spherical harmonics method via the method of manufactured solutions

    International Nuclear Information System (INIS)

    Park, H.; De Oliveira, C. R. E.

    2007-01-01

    This paper describes the verification of the recently developed space-angle self-adaptive algorithm for the finite element-spherical harmonics method via the Method of Manufactured Solutions. This method provides a simple, yet robust way for verifying the theoretical properties of the adaptive algorithm and interfaces very well with the underlying second-order, even-parity transport formulation. Simple analytic solutions in both spatial and angular variables are manufactured to assess the theoretical performance of the a posteriori error estimates. The numerical results confirm reliability of the developed space-angle error indicators. (authors)

  8. Methods for testing transport models

    International Nuclear Information System (INIS)

    Singer, C.; Cox, D.

    1993-01-01

    This report documents progress to date under a three-year contract for developing ''Methods for Testing Transport Models.'' The work described includes (1) choice of best methods for producing ''code emulators'' for analysis of very large global energy confinement databases, (2) recent applications of stratified regressions for treating individual measurement errors as well as calibration/modeling errors randomly distributed across various tokamaks, (3) Bayesian methods for utilizing prior information due to previous empirical and/or theoretical analyses, (4) extension of code emulator methodology to profile data, (5) application of nonlinear least squares estimators to simulation of profile data, (6) development of more sophisticated statistical methods for handling profile data, (7) acquisition of a much larger experimental database, and (8) extensive exploratory simulation work on a large variety of discharges using recently improved models for transport theories and boundary conditions. From all of this work, it has been possible to define a complete methodology for testing new sets of reference transport models against much larger multi-institutional databases

  9. Second harmonic inversion for ultrasound contrast harmonic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pasovic, Mirza; Danilouchkine, Mike; Faez, Telli; Van Neer, Paul L M J; Van der Steen, Antonius F W; De Jong, Nico [THORAXCENTER, Department of Biomedical Engineering Ee2302, Erasmus MC, Rotterdam (Netherlands); Cachard, Christian; Basset, Olivier, E-mail: mirza.pasovic@creatis.insa-lyon.fr [CREATIS-LRMN, Universite de Lyon, INSA-Lyon, Universite Lyon 1, Inserm U630, CNRS UMR 5220 (France)

    2011-06-07

    Ultrasound contrast agents (UCAs) are small micro-bubbles that behave nonlinearly when exposed to an ultrasound wave. This nonlinear behavior can be observed through the generated higher harmonics in a back-scattered echo. In past years several techniques have been proposed to detect or image harmonics produced by UCAs. In these proposed works, the harmonics generated in the medium during the propagation of the ultrasound wave played an important role, since these harmonics compete with the harmonics generated by the micro-bubbles. We present a method for the reduction of the second harmonic generated during nonlinear-propagation-dubbed second harmonic inversion (SHI). A general expression for the suppression signals is also derived. The SHI technique uses two pulses, p' and p'', of the same frequency f{sub 0} and the same amplitude P{sub 0} to cancel out the second harmonic generated by nonlinearities of the medium. Simulations show that the second harmonic is reduced by 40 dB on a large axial range. Experimental SHI B-mode images, from a tissue-mimicking phantom and UCAs, show an improvement in the agent-to-tissue ratio (ATR) of 20 dB compared to standard second harmonic imaging and 13 dB of improvement in harmonic power Doppler.

  10. Second harmonic inversion for ultrasound contrast harmonic imaging

    International Nuclear Information System (INIS)

    Pasovic, Mirza; Danilouchkine, Mike; Faez, Telli; Van Neer, Paul L M J; Van der Steen, Antonius F W; De Jong, Nico; Cachard, Christian; Basset, Olivier

    2011-01-01

    Ultrasound contrast agents (UCAs) are small micro-bubbles that behave nonlinearly when exposed to an ultrasound wave. This nonlinear behavior can be observed through the generated higher harmonics in a back-scattered echo. In past years several techniques have been proposed to detect or image harmonics produced by UCAs. In these proposed works, the harmonics generated in the medium during the propagation of the ultrasound wave played an important role, since these harmonics compete with the harmonics generated by the micro-bubbles. We present a method for the reduction of the second harmonic generated during nonlinear-propagation-dubbed second harmonic inversion (SHI). A general expression for the suppression signals is also derived. The SHI technique uses two pulses, p' and p'', of the same frequency f 0 and the same amplitude P 0 to cancel out the second harmonic generated by nonlinearities of the medium. Simulations show that the second harmonic is reduced by 40 dB on a large axial range. Experimental SHI B-mode images, from a tissue-mimicking phantom and UCAs, show an improvement in the agent-to-tissue ratio (ATR) of 20 dB compared to standard second harmonic imaging and 13 dB of improvement in harmonic power Doppler.

  11. 76 FR 62961 - Lifesaving Equipment: Production Testing and Harmonization With International Standards

    Science.gov (United States)

    2011-10-11

    .... Protection of Children J. Indian Tribal Governments K. Energy Effects L. International Trade Impacts M... appropriate Coast Guard oversight ultimately promotes safety, flexibility, and autonomy by permitting experts... will accept test reports from Coast Guard-accepted independent laboratories in support of approvals for...

  12. Improved harmonization of eosin-5-maleimide binding test across different instruments and age groups.

    Science.gov (United States)

    Agarwal, Archana M; Liew, Michael A; Nussenzveig, Roberto H; Sangle, Nikhil; Heikal, Nahla; Yaish, Hassan; Christensen, Robert

    2016-11-01

    The eosin-5'maleimide (EMA) binding test has been studied extensively for the detection of hereditary spherocytosis (HS). Its performance characteristics have been compared to NaCl-based or glycerol lysis-based red cell osmotic fragility tests and cryohemolysis. HS samples are also better identified when both mean channel fluorescence (MCF) of EMA relative to controls and the coefficient of variation (CV) are analyzed. We looked at 65 normal controls including 30 adults 25-65 years old and 35 newborns and 12 HS cases. In addition to the MCF and the CV, we used a side scatter (SSC) vs. EMA fluorescence gate or "footprint" to depict where normal erythrocytes should appear. Erythrocytes that have reduced band 3 protein appear outside of the footprint. In our study, newborn data did not cluster with the samples from working age individuals. The MCF and the CVs of normal newborns were higher than normal adult group. However, the footprint data of normal samples relative to their controls was around 99.5% for each group, because the footprint was moved to fit the pattern of the normal. The inclusion of footprint parameter will help in better standardization as well as implementation of this test across different age groups as well as different instruments. © 2015 International Clinical Cytometry Society. © 2015 International Clinical Cytometry Society.

  13. Intelligent harmonic load model based on neural networks

    Science.gov (United States)

    Ji, Pyeong-Shik; Lee, Dae-Jong; Lee, Jong-Pil; Park, Jae-Won; Lim, Jae-Yoon

    2007-12-01

    In this study, we developed a RBFNs(Radial Basis Function Networks) based load modeling method with harmonic components. The developed method implemented by using harmonic information as well as fundamental frequency and voltage which are essential input factors in conventional method. Thus, the proposed method makes it possible to effectively estimate load characteristics in power lines with harmonics. The RBFNs have certain advantage such as simple structure and rapid computation ability compared with multilayer perceptron which is extensively applied for load modeling. To show the effectiveness, the proposed method has been intensively tested with various dataset acquired under the different frequency and voltage and compared it with conventional methods such as polynominal 2nd equation method, MLP and RBF without considering harmonic components.

  14. Methods, systems and apparatus for controlling third harmonic voltage when operating a multi-space machine in an overmodulation region

    Science.gov (United States)

    Perisic, Milun; Kinoshita, Michael H; Ranson, Ray M; Gallegos-Lopez, Gabriel

    2014-06-03

    Methods, system and apparatus are provided for controlling third harmonic voltages when operating a multi-phase machine in an overmodulation region. The multi-phase machine can be, for example, a five-phase machine in a vector controlled motor drive system that includes a five-phase PWM controlled inverter module that drives the five-phase machine. Techniques for overmodulating a reference voltage vector are provided. For example, when the reference voltage vector is determined to be within the overmodulation region, an angle of the reference voltage vector can be modified to generate a reference voltage overmodulation control angle, and a magnitude of the reference voltage vector can be modified, based on the reference voltage overmodulation control angle, to generate a modified magnitude of the reference voltage vector. By modifying the reference voltage vector, voltage command signals that control a five-phase inverter module can be optimized to increase output voltages generated by the five-phase inverter module.

  15. Efficiency of different methods of extra-cavity second harmonic generation of continuous wave single-frequency radiation.

    Science.gov (United States)

    Khripunov, Sergey; Kobtsev, Sergey; Radnatarov, Daba

    2016-01-20

    This work presents for the first time to the best of our knowledge a comparative efficiency analysis among various techniques of extra-cavity second harmonic generation (SHG) of continuous-wave single-frequency radiation in nonperiodically poled nonlinear crystals within a broad range of power levels. Efficiency of nonlinear radiation transformation at powers from 1 W to 10 kW was studied in three different configurations: with an external power-enhancement cavity and without the cavity in the case of single and double radiation pass through a nonlinear crystal. It is demonstrated that at power levels exceeding 1 kW, the efficiencies of methods with and without external power-enhancement cavities become comparable, whereas at even higher powers, SHG by a single or double pass through a nonlinear crystal becomes preferable because of the relatively high efficiency of nonlinear transformation and fairly simple implementation.

  16. Accuracy of three-body wave functions obtained with the correlation-function hyperspherical-harmonic method

    International Nuclear Information System (INIS)

    Haftel, M.I.; Mandelzweig, V.B.

    1990-01-01

    The local convergence and accuracy of wave functions obtained by direct solution of the Schroedinger equation with the help of the correlation-function hyperspherical-harmonic method are analyzed for ground and excited states of the helium atom and for the ground state of the positronium negative ion. The inclusion of the cusp conditions into the correlation function is shown to be of crucial importance, not only near the coalescence points, but also away from them. The proper inclusion of all cusps yields for the ground state of the helium atom the local wave-function accuracy of about 10 -7 for different interparticle distances. The omission of one of the cusps in the excited helium atom reduces the wave-function precision to 10 -2 near the corresponding coalescence point and to 10 -4 --10 -5 away from it

  17. Development of Dissolution Test Method for Drotaverine ...

    African Journals Online (AJOL)

    Development of Dissolution Test Method for Drotaverine ... Methods: Sink conditions, drug stability and specificity in different dissolution media were tested to optimize a dissolution test .... test by Prism 4.0 software, and differences between ...

  18. Harmonization of antimicrobial susceptibility testing among veterinary diagnostic laboratories in the five Nordic countries

    DEFF Research Database (Denmark)

    Petersen, A.; Aarestrup, Frank Møller; Hofshagen, Merete

    2003-01-01

    A total of 100 bacterial strains (25 Escherichia coli, 25 Salmonella enterica, 25 Staphylococcus aureus, and 25 Enterococcus strains) and four reference strains were tested for susceptibility toward 8-12 antimicrobial agents in 12 veterinary diagnostic laboratories in the five Nordic countries...... reported as vancomycin resistant. Ten laboratories identified the Enterococcus spp. to species level. All five Enterococcus faecium and 10 Enterococcus faecalis selected from the strain collection at the Danish Veterinary Institute were correctly identified by all laboratories, whereas some problems were...

  19. Studies on Hepa filter test methods

    International Nuclear Information System (INIS)

    Lee, S.H.; Jon, K.S.; Park, W.J.; Ryoo, R.

    1981-01-01

    The purpose of this study is to compare testing methods of the HEPA filter adopted in other countries with each other, and to design and construct a test duct system to establish testing methods. The American D.O.P. test method, the British NaCl test method and several other independently developed methods are compared. It is considered that the D.O.P. method is most suitable for in-plant and leak tests

  20. Life test failure of harmonic gears in a Two-axis Gimbal for the Mars Reconnaissance Orbiter Spacecraft

    Science.gov (United States)

    Johnson, Michael R.; Gehling, Russ; Head, Ray

    2006-01-01

    This paper will present a process for increasing the stiffness of harmonic gear assemblies and recommend a maximum stiffness point that, if exceeded, compromises the reliability of the gear components for long life applications.

  1. Harmonizing methods for wildlife abundance estimation and pathogen detection in Europe-a questionnaire survey on three selected host-pathogen combinations

    DEFF Research Database (Denmark)

    Schulz, Jana; Ryser-Degiorgis, Marie-Pierre; Kuiken, Thijs

    2017-01-01

    Background: The need for wildlife health surveillance as part of disease control in wildlife, domestic animals and humans on the global level is widely recognized. However, the objectives, methods and intensity of existing wildlife health surveillance programs vary greatly among European countries......, resulting in a patchwork of data that are difficult to merge and compare. This survey aimed at evaluating the need and potential for data harmonization in wildlife health in Europe. The specific objective was to collect information on methods currently used to estimate host abundance and pathogen prevalence...... estimation, there is an urgent need to develop tools for the routine collection of host abundance data in a harmonized way. Wildlife health experts are encouraged to apply the harmonized APHAEA protocols in epidemiological studies in wildlife and to increase cooperation....

  2. Solution of Schrodinger equation for Three Dimensional Harmonics Oscillator plus Rosen-Morse Non-central potential using NU Method and Romanovski Polynomials

    International Nuclear Information System (INIS)

    Cari, C; Suparmi, A

    2013-01-01

    The energy eigenvalues and eigenfunctions of Schrodinger equation for three dimensional harmonic oscillator potential plus Rosen-Morse non-central potential are investigated using NU method and Romanovski polynomial. The bound state energy eigenvalues are given in a closed form and corresponding radial wave functions are expressed in associated Laguerre polynomials while angular eigen functions are given in terms of Romanovski polynomials. The Rosen-Morse potential is considered to be a perturbation factor to the three dimensional harmonic oscillator potential that causes the increase of radial wave function amplitude and decrease of angular momentum length. Keywords: Schrodinger Equation, Three dimensional Harmonic Oscillator potential, Rosen-morse non-central potential, NU method, Romanovski Polynomials

  3. Stator current harmonics evolution by neural network method based on CFE/SS algorithm for ACEC generator of Rey Power Plant

    International Nuclear Information System (INIS)

    Soleymani, S.; Ranjbar, A.M.; Mirabedini, H.

    2001-01-01

    One method for on-line fault diagnosis in synchronous generator is stator current harmonics analysis. Then artificial neural network is considered in this paper in order to evaluate stator current harmonics in different loads. Training set of artificial neural network is made ready by generator modeling, finite element method and state space model. Many points from generator capability curve are used in order to complete this set. Artificial neural network which is used in this paper is a percept ron network with a single hidden layer, Eight hidden neurons and back propagation algorithm. Results are indicated that the trained artificial neural network can identify stator current harmonics for arbitrary load from the capability curve. The error is less than 10% in comparison with values obtained directly from the CFE-SS algorithm. The rating parameters of modeled generator are 43950 (kV A), 11(KV), 3000 (rpm), 50 (H Z), (P F=0.8)

  4. Application of He’s Energy Balance Method to Duffing-Harmonic Oscillators

    DEFF Research Database (Denmark)

    Momeni, M.; Jamshidi, j.; Barari, Amin

    2011-01-01

    In this article, He's energy balance method is applied for calculating angular frequencies of nonlinear Duffing oscillators. This method offers a promising approach by constructing a Hamiltonian for the nonlinear oscillator. We illustrate that the energy balance is very effective and convenient...... and does not require linearization or small perturbation. Contrary to the conventional methods, in energy balance, only one iteration leads to high accuracy of the solutions. It is predicted that the energy balance method finds wide applications in engineering problems....

  5. Toward the harmonization of result presentation for the eosin-5'-maleimide binding test in the diagnosis of hereditary spherocytosis.

    Science.gov (United States)

    Hunt, Linda; Greenwood, David; Heimpel, Hermann; Noel, Nigel; Whiteway, Alastair; King, May-Jean

    2015-01-01

    The eosin-5'-maleimide (EMA) Binding test measures reduced mean channel fluorescence (MCF) reading of EMA-labeled red cells (EMA-RBCs) from patients with hereditary spherocytosis (HS). Reporting test results can be either in the actual MCF reading or as a ratio by normalization of the test MCF result to the mean MCF value of six normal controls. The latter format has potential for universal reporting. We analyzed three years' archival MCF data from HS and non-HS patient groups for establishment of reference ranges of ratios for normal adults and HS. A prospective study used FC500 and FACS Canto II cytometers to analyze contemporaneously EMA-RBCs from several patient groups and normal donors. Statistical analyses of the prospective data determined the cut-off values, and the sensitivity and specificity for HS respectively for the MCF and the ratio result presentations. The effect of using fewer than six normal controls for the ratio denominator was explored. The FC500 gave a mean ratio of 0.782 (SD=0.086) in HS patients with an optimal cut-off ratio of 0.918 (98.7% specificity, 95.6% sensitivity), and gray area ratio of 0.868-0.918. The Canto II gave a mean ratio of 0.774 (SD=0.085) with an optimal cut-off ratio of 0.925 (97.1% specificity and 100% sensitivity), and gray area ratio of 0.859-0.925. Harmonization of result presentation is feasible with no apparent constraint by instrument design. Interpretation of gray-area data requires an assessment of patient's clinical presentation and family history or performing a family study. © 2014 Clinical Cytometry Society.

  6. Identification and control of harmonic distortions report on Furnas experience

    Energy Technology Data Exchange (ETDEWEB)

    Mantuano Filho, Salvatore; Medeiros, Jose Roberto de; Bezerra, Luiz Roberto; Oliveira, Denise Borges de; Praca, Antonio Augusto Souza; Paiva Fontes, Marco Antonio de; Marques, Luiz Carlos Borges C. [FURNAS, Rio de Janeiro, RJ (Brazil)

    1994-12-31

    This paper describes FURNAS experience on identification and control of harmonic distortions obtained from conservation of system operation and research for solutions. Special attention is paid to the harmonic overload observed at Ibiuna substation, the receiving end of the FURNAS HVDC transmission of the Itaipu 50 Hz energy, and the solutions that have been adopted. Methods of measurement and digital simulation have been developed and successfully tested so far. The present stage of those methods will be described. Not less important is the need for a specific legislation on harmonic distortion as explained in this paper. (author) 6 refs., 2 figs.

  7. Automatic Testing with Formal Methods

    NARCIS (Netherlands)

    Tretmans, G.J.; Belinfante, Axel

    1999-01-01

    The use of formal system specifications makes it possible to automate the derivation of test cases from specifications. This allows to automate the whole testing process, not only the test execution part of it. This paper presents the state of the art and future perspectives in testing based on

  8. Harmonic supergraphs

    International Nuclear Information System (INIS)

    Galperin, A.; Ivanov, E.; Ogievetsky, V.; Sokatchev, E.

    1985-01-01

    This paper completes a descrption of the quantization procedure in the harmonic superspace approach. The Feynman rules for N=2 matter and Yang-Mills theories are derived and the various examples of harmonic supergraph calculations are given. Calculations appear to be not more difficult than those in the N=1 case. The integration over harmonic variables does not lead to any troubles, a non-locality in these disappears on-shell. The important property is that the quantum corrections are always writen as integrals over the full harmonic superspace even though the initial action is an integral over the analytic subspace. As a by-product our results imply a very simple proof of finiteness of a wide class of the N=4, d=2 non-linear Σ-models. The most general self-couplings of hypermultiplets including those with broken SU(2) are considered.The duality relations among the N=2 linear multiplet and both kinds of hypermultiplet are established

  9. Testing the multi-configuration time-dependent Hartree-Fock method

    International Nuclear Information System (INIS)

    Zanghellini, Juergen; Kitzler, Markus; Brabec, Thomas; Scrinzi, Armin

    2004-01-01

    We test the multi-configuration time-dependent Hartree-Fock method as a new approach towards the numerical calculation of dynamical processes in multi-electron systems using the harmonic quantum dot and one-dimensional helium in strong laser pulses as models. We find rapid convergence for quantities such as ground-state population, correlation coefficient and single ionization towards the exact results. The method converges, where the time-dependent Hartree-Fock method fails qualitatively

  10. A Numerical Matrix-Based method in Harmonic Studies in Wind Power Plants

    DEFF Research Database (Denmark)

    Dowlatabadi, Mohammadkazem Bakhshizadeh; Hjerrild, Jesper; Kocewiak, Łukasz Hubert

    2016-01-01

    In the low frequency range, there are some couplings between the positive- and negative-sequence small-signal impedances of the power converter due to the nonlinear and low bandwidth control loops such as the synchronization loop. In this paper, a new numerical method which also considers...... these couplings will be presented. The numerical data are advantageous to the parametric differential equations, because analysing the high order and complex transfer functions is very difficult, and finally one uses the numerical evaluation methods. This paper proposes a numerical matrix-based method, which...

  11. Investigation of structural phase transition in strontium titanate single crystal by methods of generation of coherent and incoherent second optical harmonics

    International Nuclear Information System (INIS)

    Mishina, E.D.; Morozov, A.I.; Sigov, A.S.; Sherstyuk, N.Eh.; Aktsipetrov, O.A.; Lemanov, V.V.; Rasing, Th.

    2002-01-01

    The surface phase transition in the SrTiO 3 crystal is studied through the method of the second optical harmonic generation. The peculiarities in the nonlinear-optical response are identified at the temperature of T* = 145 K, which by 40 K exceeds the T c temperature of the structural phase transition in the crystal volume. The phenomenon of the nonlinear critical opalescence, caused by availability of the point defects, is studied. The second harmonic field and critical opalescence intensity are calculated on the basis of the phenomenological model of the nonlinear-optical processes with application of the Landau phase transition theory [ru

  12. THE HARMONIZATION AND OPTIMIZATION OF DIAGNOSTIC METHODS FOR A BELT CONVEYOR

    Directory of Open Access Journals (Sweden)

    František HELEBRANT

    2012-04-01

    Full Text Available The final aim of the project MPO FR‐T11/537 called “The Complex Diagnostic System for the Belt Transport” is a single part custom manufacturing and sale of complex diagnostic system for belt transportation and related services. The output of the project is a prototype of a diagnostic system on a model belt conveyor with prepared and certified diagnostic services and methods including their measurements and other supportive tools. The article will introduce the present state of the solution for the given grant project, especially in the field of suggested work on the diagnostic and supportive methods and other measurements.

  13. Filtering methods in tidal-affected groundwater head measurements: Application of harmonic analysis and continuous wavelet transform

    Science.gov (United States)

    Sánchez-Úbeda, Juan Pedro; Calvache, María Luisa; Duque, Carlos; López-Chicano, Manuel

    2016-11-01

    A new methodology has been developed to obtain tidal-filtered time series of groundwater levels in coastal aquifers. Two methods used for oceanography processing and forecasting of sea level data were adapted for this purpose and compared: HA (Harmonic Analysis) and CWT (Continuous Wavelet Transform). The filtering process is generally comprised of two main steps: the detection and fitting of the major tide constituents through the decomposition of the original signal and the subsequent extraction of the complete tidal oscillations. The abilities of the optional HA and CWT methods to decompose and extract the tidal oscillations were assessed by applying them to the data from two piezometers at different depths close to the shoreline of a Mediterranean coastal aquifer (Motril-Salobreña, SE Spain). These methods were applied to three time series of different lengths (one month, one year, and 3.7 years of hourly data) to determine the range of detected frequencies. The different lengths of time series were also used to determine the fit accuracies of the tidal constituents for both the sea level and groundwater heads measurements. The detected tidal constituents were better resolved with increasing depth in the aquifer. The application of these methods yielded a detailed resolution of the tidal components, which enabled the extraction of the major tidal constituents of the sea level measurements from the groundwater heads (e.g., semi-diurnal, diurnal, fortnightly, monthly, semi-annual and annual). In the two wells studied, the CWT method was shown to be a more effective method than HA for extracting the tidal constituents of highest and lowest frequencies from groundwater head measurements.

  14. Method of normal coordinates in the formulation of a system with dissipation: The harmonic oscillator

    International Nuclear Information System (INIS)

    Mshelia, E.D.

    1994-07-01

    The method of normal coordinates of the theory of vibrations is used in decoupling the motion of n oscillators (1 ≤ n ≤4) representing intrinsic degrees of freedom coupled to collective motion in a quantum mechanical model that allows the determination of the probability for energy transfer from collective to intrinsic excitations in a dissipative system. (author). 21 refs

  15. Tissue Harmonic Synthetic Aperture Imaging

    DEFF Research Database (Denmark)

    Rasmussen, Joachim

    The main purpose of this PhD project is to develop an ultrasonic method for tissue harmonic synthetic aperture imaging. The motivation is to advance the field of synthetic aperture imaging in ultrasound, which has shown great potentials in the clinic. Suggestions for synthetic aperture tissue...... system complexity compared to conventional synthetic aperture techniques. In this project, SASB is sought combined with a pulse inversion technique for 2nd harmonic tissue harmonic imaging. The advantages in tissue harmonic imaging (THI) are expected to further improve the image quality of SASB...

  16. 49 CFR 383.133 - Testing methods.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Testing methods. 383.133 Section 383.133... STANDARDS; REQUIREMENTS AND PENALTIES Tests § 383.133 Testing methods. (a) All tests shall be constructed in... must be at least as stringent as the Federal standards. (c) States shall determine specific methods for...

  17. Harmonic engine

    Science.gov (United States)

    Bennett, Charles L [Livermore, CA

    2009-10-20

    A high efficiency harmonic engine based on a resonantly reciprocating piston expander that extracts work from heat and pressurizes working fluid in a reciprocating piston compressor. The engine preferably includes harmonic oscillator valves capable of oscillating at a resonant frequency for controlling the flow of working fluid into and out of the expander, and also preferably includes a shunt line connecting an expansion chamber of the expander to a buffer chamber of the expander for minimizing pressure variations in the fluidic circuit of the engine. The engine is especially designed to operate with very high temperature input to the expander and very low temperature input to the compressor, to produce very high thermal conversion efficiency.

  18. A Novel Method for the Current Harmonic Elimination of Industrial Power System Using Single Tuned Shunt Passive Filter

    Directory of Open Access Journals (Sweden)

    Mansoor Ahmed Soomro

    2012-01-01

    Full Text Available The automation of IPS (Industrial Power System has brought about several advantages of increased productivity and efficiency but it suffers from incompatible problems of overheating, noise, complexity etc, which disturb its smooth and fault tolerant implication. When the resonance condition is reached, these effects become detrimental and disturb the whole power system. The purpose of this research work is to include single tuned shunt type passive filter for harmonic elimination of the components used in industrial power system. For this purpose, MATLAB simulation using sim Power system tool has been used to analyze the effects of current harmonics. Third harmonic effects have been removed by the addition of six pulse converter technique. The simulation results show that implication of single tuned shunt (parallel connected passive filter removes effects of succeeding order current harmonics i.e. fifth, seventh and eleventh etc. which are causing substantial damage to industrial power system. The effects of current harmonics can be solved by installing without and with the application of proposed filter. Further, it is observed that these filters contribute in reduction of THD (Total Harmonic Current Distortion followed by improvement in power factor. These results are taken considering limits of IEEE 519-1992 standards.

  19. 40 CFR 63.547 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Test methods. 63.547 Section 63.547... Hazardous Air Pollutants from Secondary Lead Smelting § 63.547 Test methods. (a) The following test methods...), and 63.545(e): (1) Method 1 shall be used to select the sampling port location and the number of...

  20. On the advantage of the finite fourier transformation method for the solution of a multigroup transport equation by the spherical harmonics method

    International Nuclear Information System (INIS)

    Kobayashi, K.

    1995-01-01

    A simple formulation to derive second order differential equations of the spherical harmonics method is described, and it is shown that there is difficulty in deriving finite difference equations for these differential equations at material interfaces, because the second order differential terms of higher order moments must be expressed by the values in a mesh box. On the other hand, it is shown that there is no such difficulty, if the author uses the finite Fourier transformation method, since the differential equations are transformed into integral equations and the differentiation corresponds simply to a multiplication by the transformation parameter. Solution can be obtained in the form of Fourier series without making use of the inversion integral

  1. Using Simple Harmonic Motion to Follow the Galilean Moons--Testing Kepler's Third Law on a Small System

    Science.gov (United States)

    de Moraes, I. G.; Pereira, J. A. M.

    2009-01-01

    The motion of the four Galilean moons of Jupiter is studied in this work. The moons had their positions with respect to the centre of the planet measured during one week of observation by means of telescopic charge coupled device images. It is shown that their movement can be well described as a simple harmonic motion. The revolution period and…

  2. Comparative methods to assess harmonic response of nonlinear piezoelectric energy harvesters interfaced with AC and DC circuits

    Science.gov (United States)

    Lan, Chunbo; Tang, Lihua; Harne, Ryan L.

    2018-05-01

    Nonlinear piezoelectric energy harvester (PEH) has been widely investigated during the past few years. Among the majority of these researches, a pure resistive load is used to evaluate power output. To power conventional electronics in practical application, the alternating current (AC) generated by nonlinear PEH needs to be transformed into a direct current (DC) and rectifying circuits are required to interface the device and electronic load. This paper aims at exploring the critical influences of AC and DC interface circuits on nonlinear PEH. As a representative nonlinear PEH, we fabricate and evaluate a monostable PEH in terms of generated power and useful operating bandwidth when it is connected to AC and DC interface circuits. Firstly, the harmonic balance analysis and equivalent circuit representation method are utilized to tackle the modeling of nonlinear energy harvesters connected to AC and DC interface circuits. The performances of the monostable PEH connected to these interface circuits are then analyzed and compared, focusing on the influences of the varying load, excitation and electromechanical coupling strength on the nonlinear dynamics, bandwidth and harvested power. Subsequently, the behaviors of the monostable PEH with AC and DC interface circuits are verified by experiment. Results indicate that both AC and DC interface circuits have a peculiar influence on the power peak shifting and operational bandwidth of the monostable PEH, which is quite different from that on the linear PEH.

  3. Determination of Optimal Imaging Mode for Ultrasonographic Detection of Subdermal Contraceptive Rods: Comparison of Spatial Compound, Conventional, and Tissue Harmonic Imaging Methods

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Jin; Seo, Kyung; Song, Ho Taek; Park, Ah Young; Kim, Yaena; Yoon, Choon Sik [Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Suh, Jin Suck; Kim, Ah Hyun [Dept. of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Ryu, Jeong Ah [Dept. of Radiology, Guri Hospital, Hanyang University College of Medicine, Guri (Korea, Republic of); Park, Jeong Seon [Dept. of Radiology, Hanyang University Hospital, Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2012-09-15

    To determine which mode of ultrasonography (US), among the conventional, spatial compound, and tissue-harmonic methods, exhibits the best performance for the detection of Implanon with respect to generation of posterior acoustic shadowing (PAS). A total of 21 patients, referred for localization of impalpable Implanon, underwent US, using the three modes with default settings (i.e., wide focal zone). Representative transverse images of the rods, according to each mode for all patients, were obtained. The resulting 63 images were reviewed by four observers. The observers provided a confidence score for the presence of PAS, using a five-point scale ranging from 1 (definitely absent) to 5 (definitely present), with scores of 4 or 5 for PAS being considered as detection. The average scores of PAS, obtained from the three different modes for each observer, were compared using one-way repeated measure ANOVA. The detection rates were compared using a weighted least square method. Statistically, the tissue harmonic mode was significantly superior to the other two modes, when comparing the average scores of PAS for all observers (p < 0.00-1). The detection rate was also highest for the tissue harmonic mode (p < 0.001). Tissue harmonic mode in US appears to be the most suitable in detecting subdermal contraceptive implant rods.

  4. Determination of Optimal Imaging Mode for Ultrasonographic Detection of Subdermal Contraceptive Rods: Comparison of Spatial Compound, Conventional, and Tissue Harmonic Imaging Methods

    International Nuclear Information System (INIS)

    Kim, Sung Jin; Seo, Kyung; Song, Ho Taek; Park, Ah Young; Kim, Yaena; Yoon, Choon Sik; Suh, Jin Suck; Kim, Ah Hyun; Ryu, Jeong Ah; Park, Jeong Seon

    2012-01-01

    To determine which mode of ultrasonography (US), among the conventional, spatial compound, and tissue-harmonic methods, exhibits the best performance for the detection of Implanon with respect to generation of posterior acoustic shadowing (PAS). A total of 21 patients, referred for localization of impalpable Implanon, underwent US, using the three modes with default settings (i.e., wide focal zone). Representative transverse images of the rods, according to each mode for all patients, were obtained. The resulting 63 images were reviewed by four observers. The observers provided a confidence score for the presence of PAS, using a five-point scale ranging from 1 (definitely absent) to 5 (definitely present), with scores of 4 or 5 for PAS being considered as detection. The average scores of PAS, obtained from the three different modes for each observer, were compared using one-way repeated measure ANOVA. The detection rates were compared using a weighted least square method. Statistically, the tissue harmonic mode was significantly superior to the other two modes, when comparing the average scores of PAS for all observers (p < 0.00-1). The detection rate was also highest for the tissue harmonic mode (p < 0.001). Tissue harmonic mode in US appears to be the most suitable in detecting subdermal contraceptive implant rods.

  5. Improved H-κ Method by Harmonic Analysis on Ps and Crustal Multiples in Receiver Functions with respect to Dipping Moho and Crustal Anisotropy

    Science.gov (United States)

    Li, J.; Song, X.; Wang, P.; Zhu, L.

    2017-12-01

    The H-κ method (Zhu and Kanamori, 2000) has been widely used to estimate the crustal thickness and Vp/Vs ratio with receiver functions. However, in regions where the crustal structure is complicated, the method may produce uncertain or even unrealistic results, arising particularly from dipping Moho and/or crustal anisotropy. Here, we propose an improved H-κ method, which corrects for these effects first before stacking. The effect of dipping Moho and crustal anisotropy on Ps receiver function has been well studied, but not as much on crustal multiples (PpPs and PpSs+PsPs). Synthetic tests show that the effect of crustal anisotropy on the multiples are similar to Ps, while the effect of dipping Moho on the multiples is 5 times that on Ps (same cosine trend but 5 times in time shift). A Harmonic Analysis (HA) method for dipping/anisotropy was developed by Wang et al. (2017) for crustal Ps receiver functions to extract parameters of dipping Moho and crustal azimuthal anisotropy. In real data, the crustal multiples are much more complicated than the Ps. Therefore, we use the HA method (Wang et al., 2017), but apply separately to Ps and the multiples. It shows that although complicated, the trend of multiples can still be reasonably well represented by the HA. We then perform separate azimuthal corrections for Ps and the multiples and stack to obtain a combined receiver function. Lastly, the traditional H-κ procedure is applied to the stacked receiver function. We apply the improved H-κ method on 40 CNDSN (Chinese National Digital Seismic Network) stations distributed in a variety of geological setting across the Chinese continent. The results show apparent improvement compared to the traditional H-κ method, with clearer traces of multiples and stronger stacking energy in the grid search, as well as more reliable H-κ values.

  6. Second harmonic generation imaging

    CERN Document Server

    2013-01-01

    Second-harmonic generation (SHG) microscopy has shown great promise for imaging live cells and tissues, with applications in basic science, medical research, and tissue engineering. Second Harmonic Generation Imaging offers a complete guide to this optical modality, from basic principles, instrumentation, methods, and image analysis to biomedical applications. The book features contributions by experts in second-harmonic imaging, including many pioneering researchers in the field. Written for researchers at all levels, it takes an in-depth look at the current state of the art and possibilities of SHG microscopy. Organized into three sections, the book: Provides an introduction to the physics of the process, step-by-step instructions on how to build an SHG microscope, and comparisons with related imaging techniques Gives an overview of the capabilities of SHG microscopy for imaging tissues and cells—including cell membranes, muscle, collagen in tissues, and microtubules in live cells—by summarizing experi...

  7. Utilizing harmonization and common surveillance methods to consolidate 4 cohorts: the Western Alaska Tribal Collaborative for Health (WATCH study

    Directory of Open Access Journals (Sweden)

    Kathryn R. Koller

    2013-05-01

    Full Text Available Background. According to health status reports, chronic disease prevalence appears to be rising in western Alaska Native (AN people, and accurate population-based data are needed. Four cohort studies of western AN people were conducted in the Norton Sound and Yukon-Kuskokwim regions, but none have been large enough to allow reliable estimates of rates of chronic diseases and evaluate their risk factors. Objective. In this article, the methods used to combine 4 major cohort studies of rural western AN people are described and the benefits and challenges encountered in combining data and standardizing surveillance methods for these studies are discussed. Design. Tribal permission was obtained for each cohort study and the consolidated study. Data from baseline exams were directly combined or harmonized into new variables. Common surveillance methods were developed and implemented to identify incidence and risk factors for cardiovascular disease (CVD events and type 2 diabetes. Results. A cohort of 4,569 western AN participants (2,116 men and 2,453 women, aged 18–95 years, was established to study CVD and diabetes prevalence. Prospective surveillance data over an average 6.7-year follow-up can now be used to study CVD and diabetes incidence and associated risk factors in a subset of 2,754 western AN participants (1,218 men and 1,536 women who consented to initial surveillance. Conclusions. The combined cohort provides statistical power to examine incidence rates and risk factors for CVD and diabetes and allows for analyses by geographic region. The data can be used to develop intervention programmes in these populations and others.

  8. Alternative Test Method for Olefins in Gasoline

    Science.gov (United States)

    This action proposes to allow for an additional alternative test method for olefins in gasoline, ASTM D6550-05. The allowance of this additional alternative test method will provide more flexibility to the regulated industry.

  9. Myasthenia Gravis: Tests and Diagnostic Methods

    Science.gov (United States)

    ... Focus on MG Newsletter MG Quarterly Test & Diagnostic methods In addition to a complete medical and neurological ... How can I help? About MGFA Test & Diagnostic methods Treatment for MG FAQ's Upcoming Events 2018 MG ...

  10. Fast evaluation of solid harmonic Gaussian integrals for local resolution-of-the-identity methods and range-separated hybrid functionals

    Science.gov (United States)

    Golze, Dorothea; Benedikter, Niels; Iannuzzi, Marcella; Wilhelm, Jan; Hutter, Jürg

    2017-01-01

    An integral scheme for the efficient evaluation of two-center integrals over contracted solid harmonic Gaussian functions is presented. Integral expressions are derived for local operators that depend on the position vector of one of the two Gaussian centers. These expressions are then used to derive the formula for three-index overlap integrals where two of the three Gaussians are located at the same center. The efficient evaluation of the latter is essential for local resolution-of-the-identity techniques that employ an overlap metric. We compare the performance of our integral scheme to the widely used Cartesian Gaussian-based method of Obara and Saika (OS). Non-local interaction potentials such as standard Coulomb, modified Coulomb, and Gaussian-type operators, which occur in range-separated hybrid functionals, are also included in the performance tests. The speed-up with respect to the OS scheme is up to three orders of magnitude for both integrals and their derivatives. In particular, our method is increasingly efficient for large angular momenta and highly contracted basis sets.

  11. The Harmonics of Kansei Images

    DEFF Research Database (Denmark)

    Su, Jianning; Restrepo-Giraldo, John Dairo

    2008-01-01

    sensibility it elicits on a person (kansei), is a key factor in the design of tools to support designers in delivering the right product’s appearance. This paper presents an approach to mathematically represent a product’s kansei based on the frequency signature (harmonics) of a shape. This mathematical...... representation should allow the automatic indexing and retrieval of images from a repository of design precedents. This is done through a series of experiments aiming at determining the relation between images, kansei words and the frequency signatures of those images. Tests suggest the method is promising...... and can be used for indexing images in Content Based Image Retrieval Systems....

  12. Higher order harmonics of reactor neutron equation

    International Nuclear Information System (INIS)

    Li Fu; Hu Yongming; Luo Zhengpei

    1996-01-01

    The flux mapping method using the higher order harmonics of the neutron equation is proposed. Based on the bi-orthogonality of the higher order harmonics, the process and formulas for higher order harmonics calculation are derived via the source iteration method with source correction. For the first time, not only any order harmonics for up-to-3-dimensional geometry are achieved, but also the preliminary verification to the capability for flux mapping have been carried out

  13. Fast Harmonic Chirp Summation

    DEFF Research Database (Denmark)

    Nielsen, Jesper Kjær; Jensen, Tobias Lindstrøm; Jensen, Jesper Rindom

    2017-01-01

    -robust to noise, or very computationally inten- sive. In this paper, we propose a fast algorithm for the harmonic chirp summation method which has been demonstrated in the liter- ature to be accurate and robust to noise. The proposed algorithm is orders of magnitudes faster than previous algorithms which is also...

  14. 30 CFR 27.31 - Testing methods.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Testing methods. 27.31 Section 27.31 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Test Requirements § 27.31 Testing methods. A methane...

  15. 40 CFR 80.3 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Test methods. 80.3 Section 80.3... FUELS AND FUEL ADDITIVES General Provisions § 80.3 Test methods. The lead and phosphorus content of gasoline shall be determined in accordance with test methods set forth in the appendices to this part. [47...

  16. 40 CFR 63.1546 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Test methods. 63.1546 Section 63.1546... Hazardous Air Pollutants for Primary Lead Smelting § 63.1546 Test methods. (a) The following procedure shall....1543(a)(1) through § 63.1543(a)(9) shall be determined according to the following test methods in...

  17. Error response test system and method using test mask variable

    Science.gov (United States)

    Gender, Thomas K. (Inventor)

    2006-01-01

    An error response test system and method with increased functionality and improved performance is provided. The error response test system provides the ability to inject errors into the application under test to test the error response of the application under test in an automated and efficient manner. The error response system injects errors into the application through a test mask variable. The test mask variable is added to the application under test. During normal operation, the test mask variable is set to allow the application under test to operate normally. During testing, the error response test system can change the test mask variable to introduce an error into the application under test. The error response system can then monitor the application under test to determine whether the application has the correct response to the error.

  18. Method for critical current testing

    International Nuclear Information System (INIS)

    Siddall, M.B.; Smathers, D.B.

    1989-01-01

    Superconducting critical current testing software was developed with four important features not feasible with analog test equipment. First, quasi-steady-state sample current conditions are achieved by incrementing sample current, followed by holding some milliseconds until the transient voltage decays before voltage sampling. Then the self-field correction from a helically wound sample is computed and subtracted from each sampled field reading. A copper wire inductively wound shunt which is used for quench protection has a constant measured resistance from which the shunt leakage current is computed and subtracted from the sample current by measuring the shunt voltage after each sample current reading. Finally, the critical current is recomputed from a least squares curve fit to the power law: E=A*In when the correlation coefficient for the fit is high enough to ensure a better result than the raw datum. Comparison with NBS Standard Reference Material (NbTi) and current round robin Nb/sub 3/Sn testing is examined

  19. 7 CFR 58.644 - Test methods.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Test methods. 58.644 Section 58.644 Agriculture... Procedures § 58.644 Test methods. (a) Microbiological. Microbiological determinations shall be made in accordance with the methods described in the latest edition of Standard Methods for the Examination of Dairy...

  20. Standard test method for creep-fatigue testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of mechanical properties pertaining to creep-fatigue deformation or crack formation in nominally homogeneous materials, or both by the use of test specimens subjected to uniaxial forces under isothermal conditions. It concerns fatigue testing at strain rates or with cycles involving sufficiently long hold times to be responsible for the cyclic deformation response and cycles to crack formation to be affected by creep (and oxidation). It is intended as a test method for fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. The cyclic conditions responsible for creep-fatigue deformation and cracking vary with material and with temperature for a given material. 1.2 The use of this test method is limited to specimens and does not cover testing of full-scale components, structures, or consumer products. 1.3 This test method is primarily ...

  1. Enhancing resolution and contrast in second-harmonic generation microscopy using an advanced maximum likelihood estimation restoration method

    Science.gov (United States)

    Sivaguru, Mayandi; Kabir, Mohammad M.; Gartia, Manas Ranjan; Biggs, David S. C.; Sivaguru, Barghav S.; Sivaguru, Vignesh A.; Berent, Zachary T.; Wagoner Johnson, Amy J.; Fried, Glenn A.; Liu, Gang Logan; Sadayappan, Sakthivel; Toussaint, Kimani C.

    2017-02-01

    Second-harmonic generation (SHG) microscopy is a label-free imaging technique to study collagenous materials in extracellular matrix environment with high resolution and contrast. However, like many other microscopy techniques, the actual spatial resolution achievable by SHG microscopy is reduced by out-of-focus blur and optical aberrations that degrade particularly the amplitude of the detectable higher spatial frequencies. Being a two-photon scattering process, it is challenging to define a point spread function (PSF) for the SHG imaging modality. As a result, in comparison with other two-photon imaging systems like two-photon fluorescence, it is difficult to apply any PSF-engineering techniques to enhance the experimental spatial resolution closer to the diffraction limit. Here, we present a method to improve the spatial resolution in SHG microscopy using an advanced maximum likelihood estimation (AdvMLE) algorithm to recover the otherwise degraded higher spatial frequencies in an SHG image. Through adaptation and iteration, the AdvMLE algorithm calculates an improved PSF for an SHG image and enhances the spatial resolution by decreasing the full-width-at-halfmaximum (FWHM) by 20%. Similar results are consistently observed for biological tissues with varying SHG sources, such as gold nanoparticles and collagen in porcine feet tendons. By obtaining an experimental transverse spatial resolution of 400 nm, we show that the AdvMLE algorithm brings the practical spatial resolution closer to the theoretical diffraction limit. Our approach is suitable for adaptation in micro-nano CT and MRI imaging, which has the potential to impact diagnosis and treatment of human diseases.

  2. Harmonic disturbance location by applying Bayesian inference

    NARCIS (Netherlands)

    Ye, G.; Xiang, Y.; Cuk, V.; Cobben, J.F.G.

    2016-01-01

    Harmonic pollution is one of the most important power quality issues in electric power systems. Correct location of the main harmonic disturbance source is a key step to solve the problem. This paper presents a method to detect the location of harmonic disturbance source in low voltage network

  3. Radon barrier: Method of testing airtightness

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn; Buch-Hansen, Thomas Cornelius

    2017-01-01

    The test method NBI 167/02 Radon membrane: Test of airtightness can be used for determining the airtightness of a radon barrier as a system solution. The test determines the air infiltration through the radon barrier for a number of levels of air pressure differences. The airflow through versus...... of the barrier with the low air pressure, through a well-defined opening, as a modification of the test method in general. Results, obtained using the improved test method, are shown for a number of radon barriers tested....

  4. 30 CFR 36.41 - Testing methods.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Testing methods. 36.41 Section 36.41 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF... Requirements § 36.41 Testing methods. Mobile diesel-powered transportation equipment submitted for...

  5. 40 CFR 63.465 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Test methods. 63.465 Section 63.465... Halogenated Solvent Cleaning § 63.465 Test methods. (a) Except as provided in paragraphs (f) and (g) of this... Reference Method 307 in appendix A of this part. (b) Except as provided in paragraph (g) of this section for...

  6. Harmonic analysis

    CERN Document Server

    Helson, Henry

    2010-01-01

    This second edition has been enlarged and considerably rewritten. Among the new topics are infinite product spaces with applications to probability, disintegration of measures on product spaces, positive definite functions on the line, and additional information about Weyl's theorems on equidistribution. Topics that have continued from the first edition include Minkowski's theorem, measures with bounded powers, idempotent measures, spectral sets of bounded functions and a theorem of Szego, and the Wiener Tauberian theorem. Readers of the book should have studied the Lebesgue integral, the elementary theory of analytic and harmonic functions, and the basic theory of Banach spaces. The treatment is classical and as simple as possible. This is an instructional book, not a treatise. Mathematics students interested in analysis will find here what they need to know about Fourier analysis. Physicists and others can use the book as a reference for more advanced topics.

  7. New Graphical Methods and Test Statistics for Testing Composite Normality

    Directory of Open Access Journals (Sweden)

    Marc S. Paolella

    2015-07-01

    Full Text Available Several graphical methods for testing univariate composite normality from an i.i.d. sample are presented. They are endowed with correct simultaneous error bounds and yield size-correct tests. As all are based on the empirical CDF, they are also consistent for all alternatives. For one test, called the modified stabilized probability test, or MSP, a highly simplified computational method is derived, which delivers the test statistic and also a highly accurate p-value approximation, essentially instantaneously. The MSP test is demonstrated to have higher power against asymmetric alternatives than the well-known and powerful Jarque-Bera test. A further size-correct test, based on combining two test statistics, is shown to have yet higher power. The methodology employed is fully general and can be applied to any i.i.d. univariate continuous distribution setting.

  8. Methodology for developing new test methods

    Directory of Open Access Journals (Sweden)

    A. I. Korobko

    2017-06-01

    Full Text Available The paper describes the methodology for developing new test methods and forming solutions for the development of new test methods. The basis of the methodology for developing new test methods is the individual elements of the system and process approaches. They contribute to the development of an effective research strategy for the object, the study of interrelations, the synthesis of an adequate model of the test method. The effectiveness of the developed test method is determined by the correct choice of the set of concepts, their interrelations and mutual influence. This allows you to solve the tasks assigned to achieve the goal. The methodology is based on the use of fuzzy cognitive maps. The question of the choice of the method on the basis of which the model for the formation of solutions is based is considered. The methodology provides for recording a model for a new test method in the form of a finite set of objects. These objects are significant for the test method characteristics. Then a causal relationship is established between the objects. Further, the values of fitness indicators and the observability of the method and metrological tolerance for the indicator are established. The work is aimed at the overall goal of ensuring the quality of tests by improving the methodology for developing the test method.

  9. Cathodic Delamination Accelerated Life Test Method

    National Research Council Canada - National Science Library

    Ramotowski, Thomas S

    2007-01-01

    A method for conducting an accelerated life test of a polymer coated metallic sample includes placing the sample below the water surface in a test tank containing water and an oxygen containing gas...

  10. Thermal test requirements and their verification by different test methods

    International Nuclear Information System (INIS)

    Droste, B.; Wieser, G.; Probst, U.

    1993-01-01

    The paper discusses the parameters influencing the thermal test conditions for type B-packages. Criteria for different test methods (by analytical as well as by experimental means) will be developed. A comparison of experimental results from fuel oil pool and LPG fire tests will be given. (J.P.N.)

  11. Introduction to abstract harmonic analysis

    CERN Document Server

    Loomis, Lynn H

    2011-01-01

    Written by a prominent figure in the field of harmonic analysis, this classic monograph is geared toward advanced undergraduates and graduate students and focuses on methods related to Gelfand's theory of Banach algebra. 1953 edition.

  12. The hyperspherical-harmonics expansion method and the integral-equation approach to solving the few-body problem in momentum space

    International Nuclear Information System (INIS)

    Liu, F.-Q.; Lim, T.K.

    1988-01-01

    The Faddeev and Faddeev-Yakubovsky equations for three- and four-body systems are solved by applying the hyperspherical-harmonics expansion to them in momentum space. This coupling of two popular approaches to the few-body problem together with the use of the so-called Raynal-Revai transformation, which relates hyperspherical functions, allows the few-body equations to be written as one-dimensional coupled integral equations. Numerical solutions for these are achieved through standard matrix methods; these are made straightforward, because a second transformation renders potential multipoles easily calculable. For sample potentials and a restricted size of matrix in each case, the binding energies extracted match those previously obtained in solving the Schroedinger equation through the hyperspherical-harmonics expansion in coordinate space. 9 refs

  13. Helium leak testing methods in nuclear applications

    International Nuclear Information System (INIS)

    Ahmad, Anis

    2004-01-01

    Helium mass-spectrometer leak test is the most sensitive leak test method. It gives very reliable and sensitive test results. In last few years application of helium leak testing has gained more importance due to increased public awareness of safety and environment pollution caused by number of growing chemical and other such industries. Helium leak testing is carried out and specified in most of the critical area applications like nuclear, space, chemical and petrochemical industries

  14. GA(2)LEN skin test study I: GA(2)LEN harmonization of skin prick testing: novel sensitization patterns for inhalant allergens in Europe

    DEFF Research Database (Denmark)

    Heinzerling, L M; Burbach, G J; Edenharter, G

    2009-01-01

    . It was, therefore, crucial to standardize and harmonize procedures in allergy diagnosis and treatment within Europe. AIMS: The Global Asthma and Allergy European Network (GA(2)LEN), with partners and collaborating centres across Europe, was in a unique position to take on this task. The current study...

  15. 40 CFR 59.207 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test methods. 59.207 Section 59.207 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... Compound Emission Standards for Consumer Products § 59.207 Test methods. Each manufacturer or importer...

  16. Test Methods for Robot Agility in Manufacturing.

    Science.gov (United States)

    Downs, Anthony; Harrison, William; Schlenoff, Craig

    2016-01-01

    The paper aims to define and describe test methods and metrics to assess industrial robot system agility in both simulation and in reality. The paper describes test methods and associated quantitative and qualitative metrics for assessing robot system efficiency and effectiveness which can then be used for the assessment of system agility. The paper describes how the test methods were implemented in a simulation environment and real world environment. It also shows how the metrics are measured and assessed as they would be in a future competition. The test methods described in this paper will push forward the state of the art in software agility for manufacturing robots, allowing small and medium manufacturers to better utilize robotic systems. The paper fulfills the identified need for standard test methods to measure and allow for improvement in software agility for manufacturing robots.

  17. Automated Test Methods for XML Metadata

    Science.gov (United States)

    2017-12-28

    8933 Com (661) 277 8933 email jon.morgan.2.ctr@us.af.mil Secretariat, Range Commanders Council ATTN: TEDT-WS-RCC 1510 Headquarters Avenue White...Sands Missile Range, New Mexico 88002-5110 Phone: DSN 258-1107 Com (575) 678-1107 Fax: DSN 258-7519 Com (575) 678-7519 email ...Method for Testing Syntax The test method is as follows. 1. Initialize the programming environment. 2. Write test application code to use the

  18. Metrological traceability and harmonization of medical tests: a quantum leap forward is needed to keep pace with globalization and stringent IVD-regulations in the 21st century!

    Science.gov (United States)

    Cobbaert, Christa; Smit, Nico; Gillery, Philippe

    2018-05-07

    In our efforts to advance the profession and practice of clinical laboratory medicine, strong coordination and collaboration are needed more than ever before. At the dawn of the 21st century, medical laboratories are facing many unmet clinical needs, a technological revolution promising a plethora of better biomarkers, financial constraints, a growing scarcity of well-trained laboratory technicians and a sharply increasing number of International Organization for Standardization guidelines and new regulations to which medical laboratories should comply in order to guarantee safety and effectiveness of medical test results. Although this is a global trend, medical laboratories across continents and countries are in distinct phases and experience various situations. A universal underlying requirement for safe and global use of medical test results is the standardization and harmonization of test results. Since two decades and after a number of endeavors on standardization/harmonization of medical tests, it is time to reflect on the effectiveness of the approaches used. To keep laboratory medicine sustainable, viable and affordable, clarification of the promises of metrological traceability of test results for improving sick and health care, realization of formal commitment among all stakeholders of the metrological traceability chain and preparation of a joint and global plan for action are essential prerequisites. Policy makers and regulators should not only overwhelm the diagnostic sector with oversight and regulations but should also create the conditions by establishing a global professional forum for anchoring the metrological traceability concept in the medical test domain. Even so, professional societies should have a strong voice in their (inter-) national governments to negotiate long-lasting public policy commitment and funds for global standardization of medical tests.

  19. Iterative and range test methods for an inverse source problem for acoustic waves

    International Nuclear Information System (INIS)

    Alves, Carlos; Kress, Rainer; Serranho, Pedro

    2009-01-01

    We propose two methods for solving an inverse source problem for time-harmonic acoustic waves. Based on the reciprocity gap principle a nonlinear equation is presented for the locations and intensities of the point sources that can be solved via Newton iterations. To provide an initial guess for this iteration we suggest a range test algorithm for approximating the source locations. We give a mathematical foundation for the range test and exhibit its feasibility in connection with the iteration method by some numerical examples

  20. Complex harmonic modal analysis of rotor systems

    International Nuclear Information System (INIS)

    Han, Dong Ju

    2015-01-01

    Complex harmonic analysis for rotor systems has been proposed from the strict complex modal analysis based upon Floquet theory. In this process the harmonic balance method is adopted, effectively associated with conventional eigenvalue analysis. Also, the harmonic coefficients equivalent to dFRFs in harmonic mode has been derived in practice. The modes are classified from identifying the modal characteristics, and the adaptation of harmonic balance method has been proven by comparing the results of the stability analyses from Floque theory and the eigen analysis. The modal features of each critical speed are depicted in quantitatively and qualitatively by showing that the strengths of each component of the harmonic coefficients are estimated from the order of magnitude analysis according to their harmonic patterns. This effectiveness has been verified by comparing with the numerical solutions

  1. [Harmonization of TSH Measurements.

    Science.gov (United States)

    Takeoka, Keiko; Hidaka, Yoh; Hishinuma, Akira; Ikeda, Katsuyoshi; Okubo, Shigeo; Tsuchiya, Tatsuyuki; Hashiguchi, Teruto; Furuta, Koh; Hotta, Taeko; Matsushita, Kazuyuki; Matsumoto, Hiroyuki; Murakami, Masami; Maekawa, Masato

    2016-05-01

    The measured concentration of thyroid stimulating hormone (TSH) differs depending on the reagents used. Harmonization of TSH is crucial because the decision limits are described in current clinical practice guide- lines as absolute values, e.g. 2.5 mIU/L in early pregnancy. In this study, we tried to harmonize the report- ed concentrations of TSH using the all-procedure trimmed mean. TSH was measured in 146 serum samples, with values ranging from 0.01 to 18.8 mIU/L, using 4 immunoassays. The concentration of TSH was highest with E test TOSOH and lowest with LUMIPULSE. The concentrations with each reagent were recalculated with the following formulas: E test TOSOH 0.855x-0.014; ECLusys 0.993x+0.079; ARCHITECT 1.041x- 0.010; and LUMIPULSE 1.096x-0.015. Recalculation eliminated the between-assay discrepancy. These formulas may be used until harmonization of TSH is achieved by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC).

  2. Lectures on harmonic analysis

    CERN Document Server

    Wolff, Thomas H; Shubin, Carol

    2003-01-01

    This book demonstrates how harmonic analysis can provide penetrating insights into deep aspects of modern analysis. It is both an introduction to the subject as a whole and an overview of those branches of harmonic analysis that are relevant to the Kakeya conjecture. The usual background material is covered in the first few chapters: the Fourier transform, convolution, the inversion theorem, the uncertainty principle and the method of stationary phase. However, the choice of topics is highly selective, with emphasis on those frequently used in research inspired by the problems discussed in the later chapters. These include questions related to the restriction conjecture and the Kakeya conjecture, distance sets, and Fourier transforms of singular measures. These problems are diverse, but often interconnected; they all combine sophisticated Fourier analysis with intriguing links to other areas of mathematics and they continue to stimulate first-rate work. The book focuses on laying out a solid foundation for fu...

  3. Harmonic operation of high gain harmonic generation free electron laser

    International Nuclear Information System (INIS)

    Deng Haixiao; Chinese Academy of Sciences, Beijing; Dai Zhimin

    2008-01-01

    In high gain harmonic generation (HGHG) free electron laser (FEL), with the right choice of parameters of the modulator undulator, the dispersive section and the seed laser, one may make the spatial bunching of the electron beam density distribution correspond to one of the harmonic frequencies of the radiator radiation, instead of the fundamental frequency of the radiator radiation in conventional HGHG, thus the radiator undulator is in harmonic operation (HO) mode. In this paper, we investigate HO of HGHG FEL. Theoretical analyses with universal method are derived and numerical simulations in ultraviolet and deep ultraviolet spectral regions are given. It shows that the power of the 3rd harmonic radiation in the HO of HGHG may be as high as 18.5% of the fundamental power level. Thus HO of HGHG FEL may obtain short wavelength by using lower beam energy. (authors)

  4. Comparison of testing methods for particulate filters

    International Nuclear Information System (INIS)

    Ullmann, W.; Przyborowski, S.

    1983-01-01

    Four testing methods for particulate filters were compared by using the test rigs of the National Board of Nuclear Safety and Radiation Protection: 1) Measurement of filter penetration P as a function of particle size d by using a polydisperse NaC1 test aerosol and a scintillation particle counter; 2) Modified sodium flame test for measurement of total filter penetration P for various polydisperse NaC1 test aerosols; 3) Measurement of total filter penetration P for a polydisperse NaC1 test aerosol labelled with short-lived radon daughter products; 4) Measurement of total filter penetration P for a special paraffin oil test aerosol (oil fog test used in FRG according DIN 24 184, test aerosol A). The investigations were carried out on sheets of glass fibre paper (five grades of paper). Detailed information about the four testing methods and the used particle size distributions is given. The different results of the various methods are the base for the discussion of the most important parameters which influence the filter penetration P. The course of the function P=f(d) shows the great influence of the particle size. As expected there was also found a great dependence both from the test aerosol as well as from the principle and the measuring range of the aerosol-measuring device. The differences between the results of the various test methods are greater the lower the penetration. The use of NaCl test aerosol with various particle size distributions gives great differences for the respective penetration values. On the basis of these results and the values given by Dorman conclusions are made about the investigation of particulate filters both for the determination of filter penetration P as well as for the leak test of installed filters

  5. Evaluation of the histological and mechanical features of tendon healing in a rabbit model with the use of second-harmonic-generation imaging and tensile testing.

    Science.gov (United States)

    Hase, E; Sato, K; Yonekura, D; Minamikawa, T; Takahashi, M; Yasui, T

    2016-11-01

    This study aimed to evaluate the histological and mechanical features of tendon healing in a rabbit model with second-harmonic-generation (SHG) imaging and tensile testing. A total of eight male Japanese white rabbits were used for this study. The flexor digitorum tendons in their right leg were sharply transected, and then were repaired by intratendinous stitching. At four weeks post-operatively, the rabbits were killed and the flexor digitorum tendons in both right and left legs were excised and used as specimens for tendon healing (n = 8) and control (n = 8), respectively. Each specimen was examined by SHG imaging, followed by tensile testing, and the results of the two testing modalities were assessed for correlation. While the SHG light intensity of the healing tendon samples was significantly lower than that of the uninjured tendon samples, 2D Fourier transform SHG images showed a clear difference in collagen fibre structure between the uninjured and the healing samples, and among the healing samples. The mean intensity of the SHG image showed a moderate correlation (R 2 = 0.37) with Young's modulus obtained from the tensile testing. Our results indicate that SHG microscopy may be a potential indicator of tendon healing.Cite this article: E. Hase, K. Sato, D. Yonekura, T. Minamikawa, M. Takahashi, T. Yasui. Evaluation of the histological and mechanical features of tendon healing in a rabbit model with the use of second-harmonic-generation imaging and tensile testing. Bone Joint Res 2016;5:577-585. DOI: 10.1302/2046-3758.511.BJR-2016-0162.R1. © 2016 Yasui et al.

  6. [Seed quality test methods of Paeonia suffruticosa].

    Science.gov (United States)

    Cao, Ya-Yue; Zhu, Zai-Biao; Guo, Qiao-Sheng; Liu, Li; Wang, Chang-Lin

    2014-11-01

    In order to optimize the testing methods for Paeonia suffruticosa seed quality, and provide basis for establishing seed testing rules and seed quality standard of P. suffruticosa. The seed quality of P. suffruticosa from different producing areas was measured based on the related seed testing regulations. The seed testing methods for quality items of P. suffruticosa was established preliminarily. The samples weight of P. suffruticosa was at least 7 000 g for purity analysis and was at least 700 g for test. The phenotypic observation and size measurement were used for authenticity testing. The 1 000-seed weight was determined by 100-seed method, and the water content was carried out by low temperature drying method (10 hours). After soaking in distilled water for 24 h, the seeds was treated with different temperature stratifications of day and night (25 degrees C/20 degrees C, day/night) in the dark for 60 d. After soaking in the liquor of GA3 300 mg x L(-1) for 24 h, the P. suffruticos seeds were cultured in wet sand at 15 degrees C for 12-60 days for germination testing. Seed viability was tested by TlC method.

  7. testing a consensus conference method by discussing

    African Journals Online (AJOL)

    hi-tech

    2000-10-10

    Oct 10, 2000 ... Objectives: To test the recommended consensus conference methods in Tanzania by discussing the management ... “wrong”, based on recommendations advocated in western ..... future scenarios sponsored the conference.

  8. Accelerated Test Method for Corrosion Protective Coatings

    Data.gov (United States)

    National Aeronautics and Space Administration — This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as...

  9. HARMONIC DRIVE SELECTION

    Directory of Open Access Journals (Sweden)

    Piotr FOLĘGA

    2014-03-01

    Full Text Available The variety of types and sizes currently in production harmonic drive is a problem in their rational choice. Properly selected harmonic drive must meet certain requirements during operation, and achieve the anticipated service life. The paper discusses the problems associated with the selection of the harmonic drive. It also presents the algorithm correct choice of harmonic drive. The main objective of this study was to develop a computer program that allows the correct choice of harmonic drive by developed algorithm.

  10. Solution of two-dimensional equations of neutron transport in 4P0-approximation of spherical harmonics method

    International Nuclear Information System (INIS)

    Polivanskij, V.P.

    1989-01-01

    The method to solve two-dimensional equations of neutron transport using 4P 0 -approximation is presented. Previously such approach was efficiently used for the solution of one-dimensional problems. New an attempt is made to apply the approach to solution of two-dimensional problems. Algorithm of the solution is given, as well as results of test neutron-physical calculations. A considerable as compared with diffusion approximation is shown. 11 refs

  11. Classical and multilinear harmonic analysis

    CERN Document Server

    Muscalu, Camil

    2013-01-01

    This two-volume text in harmonic analysis introduces a wealth of analytical results and techniques. It is largely self-contained and useful to graduates and researchers in pure and applied analysis. Numerous exercises and problems make the text suitable for self-study and the classroom alike. The first volume starts with classical one-dimensional topics: Fourier series; harmonic functions; Hilbert transform. Then the higher-dimensional Calderón-Zygmund and Littlewood-Paley theories are developed. Probabilistic methods and their applications are discussed, as are applications of harmonic analysis to partial differential equations. The volume concludes with an introduction to the Weyl calculus. The second volume goes beyond the classical to the highly contemporary and focuses on multilinear aspects of harmonic analysis: the bilinear Hilbert transform; Coifman-Meyer theory; Carleson's resolution of the Lusin conjecture; Calderón's commutators and the Cauchy integral on Lipschitz curves. The material in this vo...

  12. MODERN METHODS OF FOOD INTOLERANCE TESTING

    Directory of Open Access Journals (Sweden)

    M. Yu. Rosensteyn

    2016-01-01

    Full Text Available Аn analytical review of modern methods of food intolerance diagnostics based on interpretation of markers used in the various tests is рresented. It is shown that tests based on observation of the reaction of specific antibodies of the immune system to food antigens tested, are the most accurate, reliable and representative for the diagnosis of food intolerance.

  13. Switching kinetics of a relaxor ferroelectric Sr0.75Ba0.25Nb2O6 observed by the second harmonic generation method

    International Nuclear Information System (INIS)

    Volk, Tatyana; Isakov, Dmitry; Belsley, Michael Scott; Ivleva, Lyudmila

    2009-01-01

    In this work we present a study of the ferroelectric switching kinetic process in strontium-barium niobate (SBN). The kinetics of polarization deduced from the dynamics of the diffuse second harmonic generation is in good qualitative agreement with thekinetics observed by more traditional polarization methods. Our work highlights the specific characteristics of polarization reversal in SBN, which is fundamentally different from that which occurs in model ferroelectrics. The presented optical measurements of the polarization processes provide several experimental advantages over traditional electrical measurements. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  14. Testing a simple control law to reduce broadband frequency harmonic vibrations using semi-active tuned mass dampers

    International Nuclear Information System (INIS)

    Moutinho, Carlos

    2015-01-01

    This paper is focused on the control problems related to semi-active tuned mass dampers (TMDs) used to reduce harmonic vibrations, specially involving civil structures. A simplified version of the phase control law is derived and its effectiveness is investigated and evaluated. The objective is to improve the functioning of control systems of this type by simplifying the measurement process and reducing the number of variables involved, making the control system more feasible and reliable. Because the control law is of ON/OFF type, combined with appropriate trigger conditions, the activity of the actuation system may be significantly reduced, which may be of few seconds a day in many practical cases, increasing the durability of the device and reducing its maintenance. Moreover, due to the ability of the control system to command the motion of the inertial mass, the semi-active TMD is relatively insensitive to its initial tuning, resulting in the capability of self-tuning and in the possibility of controlling several vibration modes of a structure over a significant broadband frequency. (paper)

  15. ASTM Validates Air Pollution Test Methods

    Science.gov (United States)

    Chemical and Engineering News, 1973

    1973-01-01

    The American Society for Testing and Materials (ASTM) has validated six basic methods for measuring pollutants in ambient air as the first part of its Project Threshold. Aim of the project is to establish nationwide consistency in measuring pollutants; determining precision, accuracy and reproducibility of 35 standard measuring methods. (BL)

  16. Standard test method for dynamic tear testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1983-01-01

    1.1 This test method covers the dynamic tear (DT) test using specimens that are 3/16 in. to 5/8 in. (5 mm to 16 mm) inclusive in thickness. 1.2 This test method is applicable to materials with a minimum thickness of 3/16 in. (5 mm). 1.3 The pressed-knife procedure described for sharpening the notch tip generally limits this test method to materials with a hardness level less than 36 HRC. Note 1—The designation 36 HRC is a Rockwell hardness number of 36 on Rockwell C scale as defined in Test Methods E 18. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  17. Efficiency Test Method for Electric Vehicle Chargers

    DEFF Research Database (Denmark)

    Kieldsen, Andreas; Thingvad, Andreas; Martinenas, Sergejus

    2016-01-01

    This paper investigates different methods for measuring the charger efficiency of mass produced electric vehicles (EVs), in order to compare the different models. The consumers have low attention to the loss in the charger though the impact on the driving cost is high. It is not a high priority...... different vehicles. A unified method for testing the efficiency of the charger in EVs, without direct access to the component, is presented. The method is validated through extensive tests of the models Renault Zoe, Nissan LEAF and Peugeot iOn. The results show a loss between 15 % and 40 %, which is far...

  18. Multiple-bunch-length operating mode design for a storage ring using hybrid low alpha and harmonic cavity method

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Weiwei, E-mail: gaomqr@mail.ustc.edu.cn [College of Mathematics and Physics, Fujian University of Technology, Fuzhou 350118 (China); Wang, Lin; Li, Heting [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029 (China)

    2017-03-11

    In this paper we design a simultaneous three bunch length operating mode at the HLS-II (Hefei Light Source II) storage ring by installing two harmonic cavities and minimizing the momentum compaction factor. The short bunches (2.6 mm) presented in this work will meet the requirement of coherent millimeter-wave and sub-THz radiation experiments, while the long bunches (20 mm) will efficiently increase the total beam current. Therefore, this multiple-bunch-length operating mode allows present synchrotron users and coherent millimeter-wave users (or sub THz users) to carry out their experiments simultaneously. Since the relatively low energy characteristic of HLS-II we achieve the multiple-bunch-length operating mode without multicell superconducting RF cavities, which is technically feasible.

  19. Advanced Testing Method for Ground Thermal Conductivity

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaobing [ORNL; Clemenzi, Rick [Geothermal Design Center Inc.; Liu, Su [University of Tennessee (UT)

    2017-04-01

    A new method is developed that can quickly and more accurately determine the effective ground thermal conductivity (GTC) based on thermal response test (TRT) results. Ground thermal conductivity is an important parameter for sizing ground heat exchangers (GHEXs) used by geothermal heat pump systems. The conventional GTC test method usually requires a TRT for 48 hours with a very stable electric power supply throughout the entire test. In contrast, the new method reduces the required test time by 40%–60% or more, and it can determine GTC even with an unstable or intermittent power supply. Consequently, it can significantly reduce the cost of GTC testing and increase its use, which will enable optimal design of geothermal heat pump systems. Further, this new method provides more information about the thermal properties of the GHEX and the ground than previous techniques. It can verify the installation quality of GHEXs and has the potential, if developed, to characterize the heterogeneous thermal properties of the ground formation surrounding the GHEXs.

  20. Multipath interference test method for distributed amplifiers

    Science.gov (United States)

    Okada, Takahiro; Aida, Kazuo

    2005-12-01

    A method for testing distributed amplifiers is presented; the multipath interference (MPI) is detected as a beat spectrum between the multipath signal and the direct signal using a binary frequency shifted keying (FSK) test signal. The lightwave source is composed of a DFB-LD that is directly modulated by a pulse stream passing through an equalizer, and emits the FSK signal of the frequency deviation of about 430MHz at repetition rate of 80-100 kHz. The receiver consists of a photo-diode and an electrical spectrum analyzer (ESA). The base-band power spectrum peak appeared at the frequency of the FSK frequency deviation can be converted to amount of MPI using a calibration chart. The test method has improved the minimum detectable MPI as low as -70 dB, compared to that of -50 dB of the conventional test method. The detailed design and performance of the proposed method are discussed, including the MPI simulator for calibration procedure, computer simulations for evaluating the error caused by the FSK repetition rate and the fiber length under test and experiments on singlemode fibers and distributed Raman amplifier.

  1. Test strip and method for its use

    International Nuclear Information System (INIS)

    1981-01-01

    A test strip device is described which is useful in performing binding assays involving antigens, antibodies, hormones, vitamins, metabolites or pharmacological agents. The device is capable of application to analytical methods in which a set of sequential test reactions is involved and in which a minute sample size may be used. This test strip is particularly useful in radioimmunoassays. The use of the device is illustrated in radioimmunoassays for 1) thyroxine in serum, 2) the triiodothyronine binding capacity of serum and 3) folic acid and its analogues in serum. (U.K.)

  2. Hermitian harmonic maps into convex balls

    International Nuclear Information System (INIS)

    Li Zhenyang; Xi Zhang

    2004-07-01

    In this paper, we consider Hermitian harmonic maps from Hermitian manifolds into convex balls. We prove that there exist no non-trivial Hermitian harmonic maps from closed Hermitian manifolds into convex balls, and we use the heat flow method to solve the Dirichlet problem for Hermitian harmonic maps when the domain is compact Hermitian manifold with non-empty boundary. The case where the domain manifold is complete(noncompact) is also studied. (author)

  3. Standard test methods for bend testing of material for ductility

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover bend testing for ductility of materials. Included in the procedures are four conditions of constraint on the bent portion of the specimen; a guided-bend test using a mandrel or plunger of defined dimensions to force the mid-length of the specimen between two supports separated by a defined space; a semi-guided bend test in which the specimen is bent, while in contact with a mandrel, through a specified angle or to a specified inside radius (r) of curvature, measured while under the bending force; a free-bend test in which the ends of the specimen are brought toward each other, but in which no transverse force is applied to the bend itself and there is no contact of the concave inside surface of the bend with other material; a bend and flatten test, in which a transverse force is applied to the bend such that the legs make contact with each other over the length of the specimen. 1.2 After bending, the convex surface of the bend is examined for evidence of a crack or surface irregu...

  4. Supplementary test method for carbon filters

    International Nuclear Information System (INIS)

    Normann, B.; Pettersson, S.-O.

    1980-11-01

    A test method for carbon filters using freon to detect leakage is described. The filters are used in nuclear power plants and in air-raid shelters to separate radioactive iodine.Sampling and detection limits are described and a proposal for a complete equipment is made.(G.B.)

  5. Validation of qualitative microbiological test methods

    NARCIS (Netherlands)

    IJzerman-Boon, Pieta C.; van den Heuvel, Edwin R.

    2015-01-01

    This paper considers a statistical model for the detection mechanism of qualitative microbiological test methods with a parameter for the detection proportion (the probability to detect a single organism) and a parameter for the false positive rate. It is demonstrated that the detection proportion

  6. Standard test method for creep-fatigue crack growth testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of creep-fatigue crack growth properties of nominally homogeneous materials by use of pre-cracked compact type, C(T), test specimens subjected to uniaxial cyclic forces. It concerns fatigue cycling with sufficiently long loading/unloading rates or hold-times, or both, to cause creep deformation at the crack tip and the creep deformation be responsible for enhanced crack growth per loading cycle. It is intended as a guide for creep-fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. Therefore, this method requires testing of at least two specimens that yield overlapping crack growth rate data. The cyclic conditions responsible for creep-fatigue deformation and enhanced crack growth vary with material and with temperature for a given material. The effects of environment such as time-dependent oxidation in enhancing the crack growth ra...

  7. Determination of the most reactivity control rod by pseudo-harmonics perturbation method; Determinacao da barra de controle mais reativa usando o metodo de pseudo-harmonicos

    Energy Technology Data Exchange (ETDEWEB)

    Freire, Fernando S.; Silva, Fernando C.; Martinez, Aquilino S. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear]. E-mail: ffreire@con.ufrj.br; fernando@con.ufrj.br; aquilino@.con.ufrj.br

    2005-07-01

    Frequently it is necessary to compute the change in core multiplication caused by a change in the core temperature or composition. Even when this perturbation is localized, such as a control rod inserted into the core, one does not have to repeat the original criticality calculation, but instead we can use the well-known pseudo-harmonics perturbation method to express the corresponding change in the multiplication factor in terms of the neutron flux expanded in the basis vectors characterizing the unperturbed core. Therefore we may compute the control rod worth to find the most reactivity control rod to calculate the fast shutdown margin. In this thesis we propose a simple and precise method to identify the most reactivity control rod. (author)

  8. Geometrically nonlinear dynamic analysis of doubly curved isotropic shells resting on elastic foundation by a combination of harmonic differential quadrature-finite difference methods

    International Nuclear Information System (INIS)

    Civalek, Oemer

    2005-01-01

    The nonlinear dynamic response of doubly curved shallow shells resting on Winkler-Pasternak elastic foundation has been studied for step and sinusoidal loadings. Dynamic analogues of Von Karman-Donnel type shell equations are used. Clamped immovable and simply supported immovable boundary conditions are considered. The governing nonlinear partial differential equations of the shell are discretized in space and time domains using the harmonic differential quadrature (HDQ) and finite differences (FD) methods, respectively. The accuracy of the proposed HDQ-FD coupled methodology is demonstrated by numerical examples. The shear parameter G of the Pasternak foundation and the stiffness parameter K of the Winkler foundation have been found to have a significant influence on the dynamic response of the shell. It is concluded from the present study that the HDQ-FD methodolgy is a simple, efficient, and accurate method for the nonlinear analysis of doubly curved shallow shells resting on two-parameter elastic foundation

  9. Thermo-mechanical nonlinear vibration analysis of fluid-conveying structures subjected to different boundary conditions using Galerkin-Newton-Harmonic balancing method

    Directory of Open Access Journals (Sweden)

    Gbeminiyi Sobamowo

    2017-04-01

    Full Text Available The development of mathematical models for describing the dynamic behaviours of fluid conveying pipes, micro-pipes and nanotubes under the influence of some thermo-mechanical parameters results into nonlinear equations that are very difficult to solve analytically. In cases where the exact analytical solutions are presented either in implicit or explicit forms, high skills and rigorous mathematical analyses were employed. It is noted that such solutions do not provide general exact solutions. Inevitably, comparatively simple, flexible yet accurate and practicable solutions are required for the analyses of these structures. Therefore, in this study, approximate analytical solutions are provided to the nonlinear equations arising in flow-induced vibration of pipes, micro-pipes and nanotubes using Galerkin-Newton-Harmonic Method (GNHM. The developed approximate analytical solutions are shown to be valid for both small and large amplitude oscillations. The accuracies and explicitness of these solutions were examined in limiting cases to establish the suitability of the method.

  10. Harmonic mappings into manifolds with boundary

    International Nuclear Information System (INIS)

    Chen Yunmei; Musina, R.

    1989-08-01

    In this paper we deal with harmonic maps from a compact Riemannian manifold into a manifold with boundary. In this case, a weak harmonic map is by definition a solution to a differential inclusion. In the first part of the paper we investigate the general properties of weak harmonic maps, which can be seen as solutions to a system of elliptic differential equations. In the second part we concentrate our attention on the heat flow method for harmonic maps. The result we achieve in this context extends a result by Chen and Struwe. (author). 21 refs

  11. Characterization methods for ultrasonic test systems

    International Nuclear Information System (INIS)

    Busse, L.J.; Becker, F.L.; Bowey, R.E.; Doctor, S.R.; Gribble, R.P.; Posakony, G.J.

    1982-07-01

    Methods for the characterization of ultrasonic transducers (search units) and instruments are presented. The instrument system is considered as three separate components consisting of a transducer, a receiver-display, and a pulser. The operation of each component is assessed independently. The methods presented were chosen because they provide the greatest amount of information about component operation and were not chosen based upon such conditions as cost, ease of operation, field implementation, etc. The results of evaluating a number of commercially available ultrasonic test instruments are presented

  12. Elements of abstract harmonic analysis

    CERN Document Server

    Bachman, George

    2013-01-01

    Elements of Abstract Harmonic Analysis provides an introduction to the fundamental concepts and basic theorems of abstract harmonic analysis. In order to give a reasonably complete and self-contained introduction to the subject, most of the proofs have been presented in great detail thereby making the development understandable to a very wide audience. Exercises have been supplied at the end of each chapter. Some of these are meant to extend the theory slightly while others should serve to test the reader's understanding of the material presented. The first chapter and part of the second give

  13. Thermal Testing Methods for Solar Dryers

    DEFF Research Database (Denmark)

    Singh, Shobhana

    2017-01-01

    Solar food drying is a complex heat and mass transfer phenomena which depend on a number of drying process-dependent parameters such as operating conditions and characteristics of the food product to be dried. The variation in these parameters significantly affects the overall performance...... of the dryer system. Since commercial growth and acceptance of any solar dryer system momentously depend on its performance guarantee, the development of a standard methodology for their thermal testing has become necessary. The standard testing method not only provides better performance management...... of the dryer system but allows the manufacturers to achieve competitive efficiency and good product quality by comparing the available designs. In this chapter, an extensive review of solar dryer performance evaluation has been carried out. Furthermore, the chapter describes the existing testing procedures...

  14. Assessing Social Isolation: Pilot Testing Different Methods.

    Science.gov (United States)

    Taylor, Harry Owen; Herbers, Stephanie; Talisman, Samuel; Morrow-Howell, Nancy

    2016-04-01

    Social isolation is a significant public health problem among many older adults; however, most of the empirical knowledge about isolation derives from community-based samples. There has been less attention given to isolation in senior housing communities. The objectives of this pilot study were to test two methods to identify socially isolated residents in low-income senior housing and compare findings about the extent of isolation from these two methods. The first method, self-report by residents, included 47 out of 135 residents who completed in-person interviews. To determine self-report isolation, residents completed the Lubben Social Network Scale 6 (LSNS-6). The second method involved a staff member who reported the extent of isolation on all 135 residents via an online survey. Results indicated that 26% of residents who were interviewed were deemed socially isolated by the LSNS-6. Staff members rated 12% of residents as having some or a lot of isolation. In comparing the two methods, staff members rated 2% of interviewed residents as having a lot of isolation. The combination of self-report and staff report could be more informative than just self-report alone, particularly when participation rates are low. However, researchers should be aware of the potential discrepancy between these two methods.

  15. Orthogonal Projection-Based Harmonic Signal Removal for Operational Modal Analysis

    DEFF Research Database (Denmark)

    Gres, Szymon; Andersen, Palle; Hoen, C.

    2019-01-01

    A presence of a high amplitude periodic signals in the output responses from operating structures often pose a challenge for output-only system identification and, in case of health monitoring, damage detection/localization methods. This paper introduces a pre-processing approach that removes...... the harmonic part from the output signals directly in the time domain. The new method uses orthogonal projections of the harmonic realization of the signal onto the raw time series within the stochastic subspace framework. Proposed algorithm is tested on two experimental examples. First, an aluminum plate...... excited with both random white and periodic excitations. Second, a full-scale industrial case of a ferry excited by a random environmental load with harmonic interference from a rotating machinery on-board. In both cases the proposed method removes the harmonics from the structural responses while leaving...

  16. Synthesis of Variable Harmonic Impedance in Inverter-Interfaced Distributed Generation Unit for Harmonic Damping Throughout a Distribution Network

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Chen, Zhe

    2012-01-01

    This paper proposes a harmonic impedance synthesis technique for voltage-controlled distributed generation inverters in order to damp harmonic voltage distortion on a distribution network. The approach employs a multiloop control scheme, where a selective harmonic load current feedforward loop...... at the dominant harmonic frequencies. Thus, the harmonic voltage drop on the grid-side inductance and the harmonic resonances throughout a distribution feeder with multiple shunt-connected capacitors can be effectively attenuated. Simulation and laboratory test results validate the performance of the proposed...

  17. Simplified pressure method for respirator fit testing.

    Science.gov (United States)

    Han, D; Xu, M; Foo, S; Pilacinski, W; Willeke, K

    1991-08-01

    A simplified pressure method has been developed for fit testing air-purifying respirators. In this method, the air-purifying cartridges are replaced by a pressure-sensing attachment and a valve. While wearers hold their breath, a small pump extracts air from the respirator cavity until a steady-state pressure is reached in 1 to 2 sec. The flow rate through the face seal leak is a unique function of this pressure, which is determined once for all respirators, regardless of the respirator's cavity volume or deformation because of pliability. The contaminant concentration inside the respirator depends on the degree of dilution by the flow through the cartridges. The cartridge flow varies among different brands and is measured once for each brand. The ratio of cartridge to leakflow is a measure of fit. This flow ratio has been measured on human subjects and has been compared to fit factors determined on the same subjects by means of photometric and particle count tests. The aerosol tests gave higher values of fit.

  18. Harmonics and energy management

    International Nuclear Information System (INIS)

    Andresen, M.

    1993-01-01

    To summarize what this paper has presented: Voltage and current non-sinusoidal wave shapes exist in our power system. These harmonics result from the prolific use of non-linear loads. The use of these types of loads is increasing dramatically, partly due to the push to implement energy management techniques involving harmonic generating equipment. Harmonic analysis can identify specific harmonics, their frequency, magnitude, and phase shift referenced to the fundamental. Harmonic distortion forces the use of true RMS multimeters for measurement accuracy. High levels of neutral current and N-G voltages are now possible. Transformers may overheat and fail even though they are below rated capacity. Low power factors due to harmonics cannot be corrected by the installation of capacitors, and knowledge of the fundamental VARs or the displacement power factor is needed to use capacitors alone for power factor correction. The harmonic related problems presented are by no means an exhaustive list. Many other concerns arise when harmonics are involved in the power system. The critical issue behind these problems is that many of the devices being recommended from an energy management point of view are contributing to the harmonic levels, and thus to the potential for harmonic problems. We can no longer live in the sinusoidal mentality if we are to be effective in saving energy and reducing costs

  19. The HART-II Test: Rotor Wakes and Aeroacoustics with Higher-Harmonic Pitch Control (HHC) Inputs - The Joint German/French/Dutch/US Project

    National Research Council Canada - National Science Library

    Yu, Yung H; Tung, Chee; van der Wall, Berend; Pausder, Heinz-Juergen; Burley, Casey; Brooks, Thomas; Beaumier, Philippe; Delrieux, Yves; Mercker, Edzard; Pengel, Kurt

    2002-01-01

    ...). The main objective of the program is to improve the basic understanding and the analytical modeling capabilities of rotor blade-vortex interaction noise with and without higher harmonic pitch control (HHC...

  20. Voltage harmonic elimination with RLC based interface smoothing filter

    International Nuclear Information System (INIS)

    Chandrasekaran, K; Ramachandaramurthy, V K

    2015-01-01

    A method is proposed for designing a Dynamic Voltage Restorer (DVR) with RLC interface smoothing filter. The RLC filter connected between the IGBT based Voltage Source Inverter (VSI) is attempted to eliminate voltage harmonics in the busbar voltage and switching harmonics from VSI by producing a PWM controlled harmonic voltage. In this method, the DVR or series active filter produces PWM voltage that cancels the existing harmonic voltage due to any harmonic voltage source. The proposed method is valid for any distorted busbar voltage. The operating VSI handles no active power but only harmonic power. The DVR is able to suppress the lower order switching harmonics generated by the IGBT based VSI. Good dynamic and transient results obtained. The Total Harmonic Distortion (THD) is minimized to zero at the sensitive load end. Digital simulations are carried out using PSCAD/EMTDC to validate the performance of RLC filter. Simulated results are presented. (paper)

  1. A simulation study of harmonics regeneration in noise reduction for electric and acoustic stimulation.

    Science.gov (United States)

    Hu, Yi

    2010-05-01

    Recent research results show that combined electric and acoustic stimulation (EAS) significantly improves speech recognition in noise, and it is generally established that access to the improved F0 representation of target speech, along with the glimpse cues, provide the EAS benefits. Under noisy listening conditions, noise signals degrade these important cues by introducing undesired temporal-frequency components and corrupting harmonics structure. In this study, the potential of combining noise reduction and harmonics regeneration techniques was investigated to further improve speech intelligibility in noise by providing improved beneficial cues for EAS. Three hypotheses were tested: (1) noise reduction methods can improve speech intelligibility in noise for EAS; (2) harmonics regeneration after noise reduction can further improve speech intelligibility in noise for EAS; and (3) harmonics sideband constraints in frequency domain (or equivalently, amplitude modulation in temporal domain), even deterministic ones, can provide additional benefits. Test results demonstrate that combining noise reduction and harmonics regeneration can significantly improve speech recognition in noise for EAS, and it is also beneficial to preserve the harmonics sidebands under adverse listening conditions. This finding warrants further work into the development of algorithms that regenerate harmonics and the related sidebands for EAS processing under noisy conditions.

  2. 2-d Simulations of Test Methods

    DEFF Research Database (Denmark)

    Thrane, Lars Nyholm

    2004-01-01

    One of the main obstacles for the further development of self-compacting concrete is to relate the fresh concrete properties to the form filling ability. Therefore, simulation of the form filling ability will provide a powerful tool in obtaining this goal. In this paper, a continuum mechanical...... approach is presented by showing initial results from 2-d simulations of the empirical test methods slump flow and L-box. This method assumes a homogeneous material, which is expected to correspond to particle suspensions e.g. concrete, when it remains stable. The simulations have been carried out when...... using both a Newton and Bingham model for characterisation of the rheological properties of the concrete. From the results, it is expected that both the slump flow and L-box can be simulated quite accurately when the model is extended to 3-d and the concrete is characterised according to the Bingham...

  3. Further developments in the study of harmonic analysis by the correlation and spectral density methods, and its application to the adult rabbit EEG

    International Nuclear Information System (INIS)

    Meilleurat, Michele

    1973-07-01

    The application of harmonic analysis to the brain spontaneous electrical activity has been studied theoretically and practically in 30 adult rabbits chronically implanted with electrodes. Theoretically, an accurate energetic study of the signal can only be achieved by the calculation of the autocorrelation function and its Fourier transform, the power density spectrum. Secondly, a comparative study has been made of the analogical methods using analogic or hybrid devices and the digital method with an analysis and computing program (the sampling rate, the delay, the period of integration and the problems raised by the amplification of the biological signals and sampling). Data handling is discussed, the method mainly retaining the study of variance, the calculation of the total energy carried by the signal and the energies carried along the frequency bandwidth ΔF, their percentage as related to the total energy, the relationships of these various values for various electroencephalographic states. Experimentally, the general aspect of the spontaneous electric activity of the dorsal hippocampus and the visual cortex during vigilance variations is accurately described by the calculation of the variance and the study of the position of the maximum values of the peaks of the power density spectra on the frequency axis as well as by the calculation of the energies carried in various frequency bands, 0-4, 4-8, 8-12 Hz. With the same theoretical bases, both the analogical and digital methods lead to similar results, the former being easier to operate, the latter more accurate. (author) [fr

  4. Effects of Stretching by P.N.F and Harmonic Techniques on Hamstring Flexibility

    Directory of Open Access Journals (Sweden)

    Hassan Shakeri

    2006-01-01

    Full Text Available Objective: Improving of muscle flexibility is an important issue in physiotherapy and sport sciences. There are many methods for increasing muscle length and decreasing muscle stiffness. In research findings, PNF method has been found to be better than static and ballistic methods. There is another method named Harmonic technique (introduced by E. Lederman 1997 that has been claimed to be more effective, but there is not enough documentation about this claim. Aim of this study was to compare effects of stretching by PNF and harmonic techniques on hamstring flexibility. Materials & Methods: This research is a RCT study in that 45 colledge students aged 18-35 years were arranged in three groups (Harmonic, P.N.F, and control. Subjects haven’t had any painful pathology in low-back and lower extremities for last six months. Subjects had limited hamstring length (20 degrees deficiency in Active-Knee-Extension test and hadn’t professional sport activities. Dependent variablies were muscle stiffness and hamstring length which popliteal angle in AKE test was its indirect index. In pilot study, reliability of measurement of these variables were approved. Then hamstring muscle of subjects in harmonic and PNF groups were stretched by harmonic and PNF methods for six weeks, 5 minute per day and 3d/wks, whereas control group hadn’t any exercise. Results: Findings of this study showed that in both used techniques, changes of hamstring length were significant (P=0.000, but in control group there wasn’t significant change. There wasn’t significant differences between changes of hamstring length in PNF and Harmonic groups. Only in harmonic group, muscle stiffness had significant changes (P<0.03. Conclusion: According to findings of this research, both harmonic and PNF methods equally increased length of hamstring, and harmonic technique can be used as an alternative stretching method for other techniques. Maybe harmonic technique is better than PNF

  5. Review on applied foods and analyzed methods in identification testing of irradiated foods

    International Nuclear Information System (INIS)

    Kim, Kwang Hoon; Lee, Hoo Chul; Park, Sung Hyun; Kim, Soo Jin; Kim, Kwan Soo; Jeong, Il Yun; Lee, Ju Woon; Yook, Hong Sun

    2010-01-01

    Identification methods of irradiated foods have been adopted as official test by EU and Codex. PSL, TL, ESR and GC/MS methods were registered in Korea food code on 2009 and put in force as control system of verification for labelling of food irradiation. But most generally applicable PSL and TL methods are specified applicable foods according to domestic approved items. Unlike these specifications, foods unpermitted in Korea are included in applicable items of ESR and GC/MS methods. According to recent research data, numerous food groups are possible to effective legal control by identification and these items are demanded to permit regulations for irradiation additionally. Especially, the prohibition of irradiation for meats or seafoods is not harmonized with international standards and interacts as trade friction or industrial restrictions due to unprepared domestic regulation. Hence, extension of domestic legal permission for food irradiation can contrive to related industrial development and also can reduce trade friction and enhance international competitiveness

  6. Evaluation of Harmonics Impact on Digital Relays

    Directory of Open Access Journals (Sweden)

    Kinan Wannous

    2018-04-01

    Full Text Available This paper presents the concept of the impact of harmonic distortion on a digital protection relay. The aim is to verify and determine the reasons of a mal-trip or failure to trip the protection relays; the suggested solution of the harmonic distortion is explained by a mathematical model in the Matlab Simulink programming environment. The digital relays have been tested under harmonic distortions in order to verify the function of the relays algorithm under abnormal conditions. The comparison between the protection relay algorithm under abnormal conditions and a mathematical model in the Matlab Simulink programming environment based on injected harmonics of high values is provided. The test is separated into different levels; the first level is based on the harmonic effect of an individual harmonic and mixed harmonics. The test includes the effect of the harmonics in the location of the fault point into distance protection zones. This paper is a new proposal in the signal processing of power quality disturbances using Matlab Simulink and the power quality impact on the measurements of the power system quantities; the test simulates the function of protection in power systems in terms of calculating the current and voltage values of short circuits and their faults. The paper includes several tests: frequency variations and decomposition of voltage waveforms with Fourier transforms (model and commercial relay, the effect of the power factor on the location of fault points, the relation between the tripping time and the total harmonic distortion (THD levels in a commercial relay, and a comparison of the THD capture between the commercial relay and the model.

  7. Harmonic generation with a dual frequency pulse.

    Science.gov (United States)

    Keravnou, Christina P; Averkiou, Michalakis A

    2014-05-01

    Nonlinear imaging was implemented in commercial ultrasound systems over the last 15 years offering major advantages in many clinical applications. In this work, pulsing schemes coupled with a dual frequency pulse are presented. The pulsing schemes considered were pulse inversion, power modulation, and power modulated pulse inversion. The pulse contains a fundamental frequency f and a specified amount of its second harmonic 2f. The advantages and limitations of this method were evaluated with both acoustic measurements of harmonic generation and theoretical simulations based on the KZK equation. The use of two frequencies in a pulse results in the generation of the sum and difference frequency components in addition to the other harmonic components. While with single frequency pulses, only power modulation and power modulated pulse inversion contained odd harmonic components, with the dual frequency pulse, pulse inversion now also contains odd harmonic components.

  8. Self-test Monte Carlo method

    International Nuclear Information System (INIS)

    Ohta, Shigemi

    1996-01-01

    The Self-Test Monte Carlo (STMC) method resolves the main problems in using algebraic pseudo-random numbers for Monte Carlo (MC) calculations: that they can interfere with MC algorithms and lead to erroneous results, and that such an error often cannot be detected without known exact solution. STMC is based on good randomness of about 10 10 bits available from physical noise or transcendental numbers like π = 3.14---. Various bit modifiers are available to get more bits for applications that demands more than 10 10 random bits such as lattice quantum chromodynamics (QCD). These modifiers are designed so that a) each of them gives a bit sequence comparable in randomness as the original if used separately from each other, and b) their mutual interference when used jointly in a single MC calculation is adjustable. Intermediate data of the MC calculation itself are used to quantitatively test and adjust the mutual interference of the modifiers in respect of the MC algorithm. STMC is free of systematic error and gives reliable statistical error. Also it can be easily implemented on vector and parallel supercomputers. (author)

  9. Terrestrial Water Storage in African Hydrological Regimes Derived from GRACE Mission Data: Intercomparison of Spherical Harmonics, Mass Concentration, and Scalar Slepian Methods.

    Science.gov (United States)

    Rateb, Ashraf; Kuo, Chung-Yen; Imani, Moslem; Tseng, Kuo-Hsin; Lan, Wen-Hau; Ching, Kuo-En; Tseng, Tzu-Pang

    2017-03-10

    Spherical harmonics (SH) and mascon solutions are the two most common types of solutions for Gravity Recovery and Climate Experiment (GRACE) mass flux observations. However, SH signals are degraded by measurement and leakage errors. Mascon solutions (the Jet Propulsion Laboratory (JPL) release, herein) exhibit weakened signals at submascon resolutions. Both solutions require a scale factor examined by the CLM4.0 model to obtain the actual water storage signal. The Slepian localization method can avoid the SH leakage errors when applied to the basin scale. In this study, we estimate SH errors and scale factors for African hydrological regimes. Then, terrestrial water storage (TWS) in Africa is determined based on Slepian localization and compared with JPL-mascon and SH solutions. The three TWS estimates show good agreement for the TWS of large-sized and humid regimes but present discrepancies for the TWS of medium and small-sized regimes. Slepian localization is an effective method for deriving the TWS of arid zones. The TWS behavior in African regimes and its spatiotemporal variations are then examined. The negative TWS trends in the lower Nile and Sahara at -1.08 and -6.92 Gt/year, respectively, are higher than those previously reported.

  10. Terrestrial Water Storage in African Hydrological Regimes Derived from GRACE Mission Data: Intercomparison of Spherical Harmonics, Mass Concentration, and Scalar Slepian Methods

    Directory of Open Access Journals (Sweden)

    Ashraf Rateb

    2017-03-01

    Full Text Available Spherical harmonics (SH and mascon solutions are the two most common types of solutions for Gravity Recovery and Climate Experiment (GRACE mass flux observations. However, SH signals are degraded by measurement and leakage errors. Mascon solutions (the Jet Propulsion Laboratory (JPL release, herein exhibit weakened signals at submascon resolutions. Both solutions require a scale factor examined by the CLM4.0 model to obtain the actual water storage signal. The Slepian localization method can avoid the SH leakage errors when applied to the basin scale. In this study, we estimate SH errors and scale factors for African hydrological regimes. Then, terrestrial water storage (TWS in Africa is determined based on Slepian localization and compared with JPL-mascon and SH solutions. The three TWS estimates show good agreement for the TWS of large-sized and humid regimes but present discrepancies for the TWS of medium and small-sized regimes. Slepian localization is an effective method for deriving the TWS of arid zones. The TWS behavior in African regimes and its spatiotemporal variations are then examined. The negative TWS trends in the lower Nile and Sahara at −1.08 and −6.92 Gt/year, respectively, are higher than those previously reported.

  11. Electromagnetic cyclotron harmonic waves

    International Nuclear Information System (INIS)

    Ohnuma, T.; Watanabe, T.; Hamamatsu, K.

    1981-09-01

    Electromagnetic electron cyclotron harmonic waves just below the electron cyclotron harmonics are investigated numerically and experimentally. Backward waves which are observed to propagate nearly perpendicular to the magnetic field just below the electron cyclotron frequency in a high density magnetoplasma are confirmed to be in accord with the theoretical electromagnetic cyclotron waves. (author)

  12. Structural characteristics and harmonic vibrational analysis of the stable conformer of 2,3-epoxypropanol by quantum chemical methods.

    Science.gov (United States)

    Arjunan, V; Rani, T; Santhanam, R; Mohan, S

    2012-10-01

    The FT-IR and FT-Raman spectra of H bond inner conformer of 2,3-epoxypropanol have been recorded in the regions 3700-400 and 3700-100 cm(-1), respectively. The spectra were interpreted in terms of fundamentals modes, combination and overtone bands. The normal coordinate analysis was carried out to confirm the precision of the assignments. The structure of the conformers H bond inner and H bond outer1 were optimised and the structural characteristics were determined by density functional theory (DFT) using B3LYP and MP2 methods with 6-31G** and 6-311++G** basis sets. The vibrational frequencies were calculated in all these methods and were compared with the experimental frequencies which yield good agreement between observed and calculated frequencies. The electronic properties HOMO and LUMO energies were measured by time-dependent TD-DFT approach. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Investigating student understanding of simple harmonic motion

    Science.gov (United States)

    Somroob, S.; Wattanakasiwich, P.

    2017-09-01

    This study aimed to investigate students’ understanding and develop instructional material on a topic of simple harmonic motion. Participants were 60 students taking a course on vibrations and wave and 46 students taking a course on Physics 2 and 28 students taking a course on Fundamental Physics 2 on the 2nd semester of an academic year 2016. A 16-question conceptual test and tutorial activities had been developed from previous research findings and evaluated by three physics experts in teaching mechanics before using in a real classroom. Data collection included both qualitative and quantitative methods. Item analysis and whole-test analysis were determined from student responses in the conceptual test. As results, most students had misconceptions about restoring force and they had problems connecting mathematical solutions to real motions, especially phase angle. Moreover, they had problems with interpreting mechanical energy from graphs and diagrams of the motion. These results were used to develop effective instructional materials to enhance student abilities in understanding simple harmonic motion in term of multiple representations.

  14. Probabilistic Aspects of Harmonic Emission of Large Offshore Wind Farms

    DEFF Research Database (Denmark)

    Jensen, Christian Flytkjær; Bak, Claus Leth; Kocewiak, Lukasz Hubert

    2011-01-01

    In this article, a new probabilistic method of as-sessment of harmonic emission of large offshore wind farms is presented. Based on measurements from the British wind farm Burbo Banks, probability density functions are estimated for the dominating low order harmonic currents injected by a single...... turbine. The degree and type of dependence between the harmonic emission and the operating point of a single turbine is established. A model of Burbo Banks, suitable for harmonic load flow studies, is created in DIgSILENT Power Factory along with a DPL-script that deals with the probabilistic issues...... of the harmonic emission. The simulated harmonic distortion at the PCC is compared to measurement. This reveals some diffi-culties regarding harmonic load flow studies. The harmonic background distortion in the grid to where the wind farm is connected must be included in the study. Furthermore, a very detailed...

  15. An Exact Method to Determine the Photonic Resonances of Quasicrystals Based on Discrete Fourier Harmonics of Higher-Dimensional Atomic Surfaces

    Directory of Open Access Journals (Sweden)

    Farhad A. Namin

    2016-08-01

    Full Text Available A rigorous method for obtaining the diffraction patterns of quasicrystals is presented. Diffraction patterns are an essential analytical tool in the study of quasicrystals, since they can be used to determine their photonic resonances. Previous methods for approximating the diffraction patterns of quasicrystals have relied on evaluating the Fourier transform of finite-sized super-lattices. Our approach, on the other hand, is exact in the sense that it is based on a technique that embeds quasicrystals into higher dimensional periodic hyper-lattices, thereby completely capturing the properties of the infinite structure. The periodicity of the unit cell in the higher dimensional space can be exploited to obtain the Fourier series expansion in closed-form of the corresponding atomic surfaces. The utility of the method is demonstrated by applying it to one-dimensional Fibonacci and two-dimensional Penrose quasicrystals. The results are verified by comparing them to those obtained by using the conventional super-lattice method. It is shown that the conventional super-cell approach can lead to inaccurate results due to the continuous nature of the Fourier transform, since quasicrystals have a discrete spectrum, whereas the approach introduced in this paper generates discrete Fourier harmonics. Furthermore, the conventional approach requires very large super-cells and high-resolution sampling of the reciprocal space in order to produce accurate results leading to a very large computational burden, whereas the proposed method generates accurate results with a relatively small number of terms. Finally, we propose how this approach can be generalized from the vertex model, which assumes identical particles at all vertices, to a more realistic case where the quasicrystal is composed of different atoms.

  16. Electric power quality analysis methods. Application to voltage dips and harmonic disturbances; Methodes d'analyse de la qualite de l'energie electrique. Application aux creux de tension et a la pollution harmonique

    Energy Technology Data Exchange (ETDEWEB)

    Vanya, Ignatova

    2006-10-15

    The power quality concerns all the actors in the energy domains, that they are network administrators, suppliers, producers, or consumers of electricity. The research work presented in this PhD thesis is situated in the field of the power quality monitoring. Its objective is to introduce new techniques for analysis of power quality problems. There are different methods designed for the analysis of the power quality disturbances. This method reaches very good performances in the voltage dips analysis, as it allows segmenting, classifying and characterising these power quality disturbances. The periodic systems method allows the theoretical study of the generation and the propagation of harmonic disturbances in the network. Finally, the statistical matrix method has the objective to represent statistically electrical signals without loss of important information. (author)

  17. Intense harmonic generation from various ablation media

    International Nuclear Information System (INIS)

    Ozaki, T.; Elouga, L.; Suzuki, M.; Kuroda, H.; Ganeev, R.A.

    2006-01-01

    Complete test of publication follows. High-order harmonic generation (HHG) is a unique source of coherent extreme ultraviolet (XUV) radiation, which can produce soft x-rays within the spectral 'water-window' (between 2.3 and 4.4 nm), and ultimately short pulses with attosecond duration. However, the intensity of present-day harmonics is still low, and serious applications will need an increase of the conversion efficiency. Instead of using gas media, one can also use ablation material, produced on solid targets using a low-intensity prepulse, as the nonlinear medium to generate high-order harmonics. Recently, we have successfully demonstrated the generation of up to the 63 rd harmonic (λ = 12.6 nm) of a Ti:sapphire laser radiation using boron ablation, and a strong enhancement in the intensity of the 13 th harmonic from indium ablation. These harmonics were generated with a modest laser (10 mJ, 150 fs) and with the pre-pulse to main pulse energy ratio constant. In this paper, we perform systematic investigations of ablation harmonics, using the 200 mJ, 30 fs Ti:sapphire beam line of the Canadian Advanced Laser Light Source (ALLS) facility. ALLS allows studying ablation harmonics over wider experimental parameters, and with independent control over the pre-pulse and main pulse energies. The 10 Hz, 200 mJ Ti:sapphire beam line of ALLS is divided into two beams. Each beam has its own energy control system, which allows independent control over the energy of each beam. One of the beams is used as a pre-pulse for creating ablation, which is focused onto the solid target without pulse compression, with pulse duration of 200 ps. The second beam is used as the main pulse for harmonic generation. The main pulse is delayed in time relative to the pre-pulse by propagating through an optical delay line, and then sent through a pulse compressor. The compressed pulse duration have typical pulse duration of 30 fs FWHM, which is then focused onto the ablation medium using MgF 2

  18. Challenges and Opportunities for Harmonizing Research Methodology

    DEFF Research Database (Denmark)

    van Hees, V. T.; Thaler-Kall, K.; Wolf, K. H.

    2016-01-01

    Objectives: Raw accelerometry is increasingly being used in physical activity research, but diversity in sensor design, attachment and signal processing challenges the comparability of research results. Therefore, efforts are needed to harmonize the methodology. In this article we reflect on how...... increased methodological harmonization may be achieved. Methods: The authors of this work convened for a two-day workshop (March 2014) themed on methodological harmonization of raw accelerometry. The discussions at the workshop were used as a basis for this review. Results: Key stakeholders were identified...... as manufacturers, method developers, method users (application), publishers, and funders. To facilitate methodological harmonization in raw accelerometry the following action points were proposed: i) Manufacturers are encouraged to provide a detailed specification of their sensors, ii) Each fundamental step...

  19. Harmonic supergraphs. Green functions

    International Nuclear Information System (INIS)

    Galperin, A.; Ivanov, E.; Gievetsky, V.; Sokatchev, E.

    1985-01-01

    The quantization procedure in the harmonic superspace approach is worked out. Harmonic distributions are introduced and are used to construct the analytic superspace delta-functions and the Green functions for the hypermultiplet and the N=2 Yang-Mills superfields. The gauge fixing is described and the relevant Faddeev-Popov ghosts are defined. The corresponding BRST transformations are found. The harmonic superspace quantization of the N=2 gauge theory turns out to be rather simple and has many parallels with that for the standard (N=0) Yang-Mills theory. In particular, no ghosts-forghosts are needed

  20. Determination of nonlinear resistance voltage-current relationships by measuring harmonics

    Science.gov (United States)

    Stafford, J. M.

    1971-01-01

    Test configuration measures harmonic signal amplitudes generated in nonlinear resistance. Vacuum-type voltmeter measures low frequency sinusoidal input signal amplitude and wave-analyzer measures amplitude of harmonic signals generated in junction. Input signal harmonics amplitude must not exceed that of harmonics generated in nonlinear resistance.

  1. Harmonic currents circulation in electrical networks simulation and analysis

    Energy Technology Data Exchange (ETDEWEB)

    Em-Mamlouk, W.M. [MEP, Cairo (Egypt); El-Sharkawy, M.A. [Shams Univ., Cairo (Egypt). Dept. of Electrical Power and Machines; Mostafa, H.E. [Jazan Univ., Jazan (Saudi Arabia). Electrical Dept.

    2009-07-01

    A detailed harmonic flow analysis for a 13-bus balanced industrial distribution system was presented. The aim of the study was to determine the influence of harmonic sources in various branches of the system on voltage and current waveforms before disruptions to the utility supply system occurred. The current harmonic contents of an adjustable speed drive (ASD) were studied under various loading conditions. The test system was simulated using a standard study test system. Harmonic effects from multiple sources were investigated, and voltage distortion on the different buses was monitored. The study demonstrated that while the harmonic loads circulated harmonic currents in all system branches, no harmonic source was directly connected to the system buses. Many of the investigated cases exceeded allowable voltage total harmonic distortion and or current total harmonic distortion standards set by the Institute of Electrical and Electronic Engineers (IEEE). It was concluded that active harmonic filters should be used to prevent the effects of harmonic current circulation at different buses on neighbouring loads within a system. 8 refs., 11 tabs., 15 figs.

  2. Superstrings and harmonic superspace

    International Nuclear Information System (INIS)

    Kallosh, R.E.; AN SSSR, Moscow. Fizicheskij Inst.)

    1987-01-01

    The paper on superstrings and harmonic superspace is a contribution to the book dedicated to E.S. Fradkin on his sixtieth birthday. The purpose of the paper is to propose a description of N = 2,3 superspace which could be used for the investigation of the effective d = 10 harmonic superspace corresponding to the heterotic superstring. A description is given of the structure of semi-simple Lie algebras in the Cartan-Weyl basis, as well as the general properties of the even, compact part of harmonic superspace. The main properties of the four-dimensional N = 2 SYM theory are discussed, along with the N = 3, d = 4 super Yang-Mills theory. Finally the relation between the harmonic superspace and the heterotic E 8 x E 8 superstring is examined. (U.K.)

  3. Harmonic excitations in quasicrystals

    International Nuclear Information System (INIS)

    Luck, J.M.

    1986-03-01

    The harmonic excitations (phonons) of quasicrystals are studied in a simple one-dimensional model. The spectrum is a Cantor set, which exhibits selfsimilarity properties. The eigenstates are generically ''critical'', i.e. neither extended nor localized

  4. Multidimensional high harmonic spectroscopy

    International Nuclear Information System (INIS)

    Bruner, Barry D; Soifer, Hadas; Shafir, Dror; Dudovich, Nirit; Serbinenko, Valeria; Smirnova, Olga

    2015-01-01

    High harmonic generation (HHG) has opened up a new frontier in ultrafast science where attosecond time resolution and Angstrom spatial resolution are accessible in a single measurement. However, reconstructing the dynamics under study is limited by the multiple degrees of freedom involved in strong field interactions. In this paper we describe a new class of measurement schemes for resolving attosecond dynamics, integrating perturbative nonlinear optics with strong-field physics. These approaches serve as a basis for multidimensional high harmonic spectroscopy. Specifically, we show that multidimensional high harmonic spectroscopy can measure tunnel ionization dynamics with high precision, and resolves the interference between multiple ionization channels. In addition, we show how multidimensional HHG can function as a type of lock-in amplifier measurement. Similar to multi-dimensional approaches in nonlinear optical spectroscopy that have resolved correlated femtosecond dynamics, multi-dimensional high harmonic spectroscopy reveals the underlying complex dynamics behind attosecond scale phenomena. (paper)

  5. Harmonic d-tensors

    Energy Technology Data Exchange (ETDEWEB)

    Hohmann, Manuel [Physikalisches Institut, Universitaet Tartu (Estonia)

    2016-07-01

    Tensor harmonics are a useful mathematical tool for finding solutions to differential equations which transform under a particular representation of the rotation group SO(3). In order to make use of this tool also in the setting of Finsler geometry, where the objects of relevance are d-tensors instead of tensors, we construct a set of d-tensor harmonics for both SO(3) and SO(4) symmetries and show how these can be used for calculations in Finsler geometry and gravity.

  6. 40 CFR 63.1161 - Performance testing and test methods.

    Science.gov (United States)

    2010-07-01

    ..., “Determination of Hydrogen Halide and Halogen Emissions from Stationary Sources—Isokinetic Method,” to determine... shall be 60 minutes and the minimum sample volume 0.85 dry standard cubic meters (30 dry standard cubic...(mg/dscm) is concentration in milligrams per dry standard cubic meter as calculated by the procedure...

  7. Lubricant Test Methods for Sheet Metal Forming

    DEFF Research Database (Denmark)

    Bay, Niels; Olsson, David Dam; Andreasen, Jan Lasson

    2008-01-01

    appearing in different sheet forming operations such as stretch forming, deep drawing, ironing and punching. The laboratory tests have been especially designed to model the conditions in industrial production. Application of the tests for evaluating new lubricants before introducing them in production has......Sheet metal forming of tribologically difficult materials such as stainless steel, Al-alloys and Ti-alloys or forming in tribologically difficult operations like ironing, punching or deep drawing of thick plate requires often use of environmentally hazardous lubricants such as chlorinated paraffin...... oils in order to avoid galling. The present paper describes a systematic research in the development of new, environmentally harmless lubricants focusing on the lubricant testing aspects. A system of laboratory tests has been developed to study the lubricant performance under the very varied conditions...

  8. Leak test method and test device for iodine filter

    International Nuclear Information System (INIS)

    Fukasawa, Tetsuo; Funabashi, Kiyomi; Miura, Noboru; Miura, Eiichi.

    1995-01-01

    An air introduction device which can change a humidity is disposed upstream of an iodine filter to be tested, and a humidity measuring device is disposed downstream of the iodine filter respectively. At first, dried air reduced with humidity is flown from the air introduction device to the iodine filter, to remove moisture content from an iodine adsorber in the iodine filter. Next, air at an increased humidity is supplied to the iodine filter. The difference between the time starting the supply of the highly humid air and the time detecting the high humidity at the humidity measuring device is measured. When the time difference is smaller than the time difference measured previously in a normal iodine filter, it shows the presence of leak in the iodine filter to be tested. With such procedures, leakage in the iodine filter which removes radioactive iodine from off-gases discharged from the radioactive material handling facilities can be detected easily by using water (steams), namely, a naturally present material. (I.N.)

  9. 40 CFR Appendix A to Part 63 - Test Methods

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Test Methods A Appendix A to Part 63... to Part 63—Test Methods Method 301—Field Validation of Pollutant Measurement Methods from Various Waste Media 1. Applicability and principle 1.1Applicability. This method, as specified in the applicable...

  10. Methods and models for the construction of weakly parallel tests

    NARCIS (Netherlands)

    Adema, J.J.; Adema, Jos J.

    1990-01-01

    Methods are proposed for the construction of weakly parallel tests, that is, tests with the same test information function. A mathematical programing model for constructing tests with a prespecified test information function and a heuristic for assigning items to tests such that their information

  11. Harmonic Interaction Analysis in Grid Connected Converter using Harmonic State Space (HSS) Modeling

    DEFF Research Database (Denmark)

    Kwon, Jun Bum; Wang, Xiongfei; Bak, Claus Leth

    2015-01-01

    -model, are introduced to analyze these problems. However, it is found that Linear Time Invariant (LTI) base model analysis makes it difficult to analyze these phenomenon because of time varying system operation trajectories, varying output impedance seen by grid connected systems and neglected switching component......An increasing number of power electronics based Distributed Generation (DG) systems and loads generate coupled harmonic as well as non-characteristic harmonic with each other. Several methods like impedance based analysis, which is derived from conventional small signal- and average...... during the modeling process. This paper investigates grid connected converter by means of Harmonic State Space (HSS) small signal model, which is modeled from Linear Time varying Periodically (LTP) system. Further, a grid connected converter harmonic matrix is investigated to analyze the harmonic...

  12. Development of standard testing methods for nuclear-waste forms

    International Nuclear Information System (INIS)

    Mendel, J.E.; Nelson, R.D.

    1981-11-01

    Standard test methods for waste package component development and design, safety analyses, and licensing are being developed for the Nuclear Waste Materials Handbook. This paper describes mainly the testing methods for obtaining waste form materials data

  13. Antimicrobial Testing Methods & Procedures Developed by EPA's Microbiology Laboratory

    Science.gov (United States)

    We develop antimicrobial testing methods and standard operating procedures to measure the effectiveness of hard surface disinfectants against a variety of microorganisms. Find methods and procedures for antimicrobial testing.

  14. Multi-frequency eddy current testing method

    International Nuclear Information System (INIS)

    Levy, R.; Gallet, G.

    1980-01-01

    Monitoring by multi-frequency eddy currents has been used since 1975 in French nuclear stations; this method applies perfectly to examinations in non-irradiated surroundings. The restrictions connected with operations in controlled zones (radioactivity) have led to the development of a delayed analysis device which in no way changes the principle of the method, but allows greater flexibility of use by reducing the volume of equipment needed and by limiting the intervention of personnel to a strict minimum [fr

  15. Review of Test Theory and Methods.

    Science.gov (United States)

    1981-01-01

    literature, although some books , technical reports, and unpub- lished literature have been included where relevant. The focus of the review is on practical...1977) and Abu-Sayf (1977) developed new versions of formula scores, and Molenaar (1977) took a Bayesian approach to correcting for random guessing. The...Snow’s (1977) book on aptitude and instructional methods is a landmark review of the research on the interaction between instructional methods and

  16. The Harmonic Oscillator–A Simplified Approach

    Directory of Open Access Journals (Sweden)

    L. R. Ganesan

    2008-01-01

    Full Text Available Among the early problems in quantum chemistry, the one dimensional harmonic oscillator problem is an important one, providing a valuable exercise in the study of quantum mechanical methods. There are several approaches to this problem, the time honoured infinite series method, the ladder operator method etc. A method which is much shorter, mathematically simpler is presented here.

  17. 16 CFR 1513.4 - Test methods.

    Science.gov (United States)

    2010-01-01

    ... Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS..., gradually apply a 33-lbf (147-N) force in a direction perpendicular to the plane of the large end of the... Figure 2 of this part into the portion of the boundary to be tested, with the plane of the template in...

  18. 16 CFR 1213.4 - Test methods.

    Science.gov (United States)

    2010-01-01

    ... Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY... orientation”). Then gradually apply a 33-lbf (147-N) force in a direction perpendicular to the plane of the... Figure 2 of this part into the portion of the boundary of the opening to be tested, with the plane of the...

  19. Comparison of sine dwell and broadband methods for modal testing

    Science.gov (United States)

    Chen, Jay-Chung

    1989-01-01

    The objectives of modal tests for large complex spacecraft structural systems are outlined. The comparison criteria for the modal test methods, namely, the broadband excitation and the sine dwell methods, are established. Using the Galileo spacecraft modal test and the Centaur G Prime upper stage vehicle modal test as examples, the relative advantage or disadvantage of each method is examined. The usefulness or shortcomings of the methods are given from a practical engineering viewpoint.

  20. On sine dwell or broadband methods for modal testing

    Science.gov (United States)

    Chen, Jay-Chung; Wada, Ben K.

    1987-01-01

    For large, complex spacecraft structural systems, the objectives of the modal test are outlined. Based on these objectives, the comparison criteria for the modal test methods, namely, the broadband excitation and the sine dwell methods are established. Using the Galileo spacecraft modal test and the Centaur G Prime upper stage vehicle modal test as examples, the relative advantages or disadvantages of each method are examined. The usefulness or shortcoming of the methods are given from a practicing engineer's view point.

  1. On the assessment of usability testing methods for children

    NARCIS (Netherlands)

    Markopoulos, P.; Bekker, M.M.

    2003-01-01

    The paper motivates the need to acquire methodological knowledge for involving children as test users in usability testing. It introduces a methodological framework for delineating comparative assessments of usability testing methods for children participants. This framework consists in three

  2. High-Performance Harmonic Isolation and Load Voltage Regulation of the Three-Phase Series Active Filter Utilizing the Waveform Reconstruction Method

    DEFF Research Database (Denmark)

    Senturk, Osman Selcuk; Hava, Ahmet M.

    2009-01-01

    . The SAF-compensated system utilizing WRM provides highperformance load harmonic voltage isolation and load voltage regulation at steady-state and during transients compared to the system utilizing the synchronous reference-frame-based signal decomposition. In addition, reducing the line current sampling...

  3. 40 CFR Table 3 of Subpart Bbbbbbb... - Test Methods

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Test Methods 3 Table 3 of Subpart... 3 Table 3 of Subpart BBBBBBB of Part 63—Test Methods For * * * You must use * * * 1. Selecting the sampling locations a and the number of traverse points EPA test method 1 or 1A in appendix A to part 60. 2...

  4. 40 CFR Table 3 of Subpart Aaaaaaa... - Test Methods

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Test Methods 3 Table 3 of Subpart..., Subpt. AAAAAAA, Table 3 Table 3 of Subpart AAAAAAA of Part 63—Test Methods For * * * You must use * * * 1. Selecting the sampling locations a and the number of traverse points EPA test method 1 or 1A in...

  5. Young children pause on phrase boundaries in self-paced music listening: The role of harmonic cues.

    Science.gov (United States)

    Kragness, Haley E; Trainor, Laurel J

    2018-05-01

    Proper segmentation of auditory streams is essential for understanding music. Many cues, including meter, melodic contour, and harmony, influence adults' perception of musical phrase boundaries. To date, no studies have examined young children's musical grouping in a production task. We used a musical self-pacing method to investigate (1) whether dwell times index young children's musical phrase grouping and, if so, (2) whether children dwell longer on phrase boundaries defined by harmonic cues specifically. In Experiment 1, we asked 3-year-old children to self-pace through chord progressions from Bach chorales (sequences in which metrical, harmonic, and melodic contour grouping cues aligned) by pressing a computer key to present each chord in the sequence. Participants dwelled longer on chords in the 8th position, which corresponded to phrase endings. In Experiment 2, we tested 3-, 4-, and 7-year-old children's sensitivity to harmonic cues to phrase grouping when metrical regularity cues and melodic contour cues were misaligned with the harmonic phrase boundaries. In this case, 7 and 4 year olds but not 3 year olds dwelled longer on harmonic phrase boundaries, suggesting that the influence of harmonic cues on phrase boundary perception develops substantially between 3 and 4 years of age in Western children. Overall, we show that the musical dwell time method is child-friendly and can be used to investigate various aspects of young children's musical understanding, including phrase grouping and harmonic knowledge. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  6. Atmospheric methods for nuclear test monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Simons, D.J. [Los Alamos National Laboratory, NM (United States)

    1994-12-31

    This report describes two atmomospheric methods for the monitoring and detection of underground nuclear explosions: Near infrasound technique, and ionospheric monitoring. Ground motion from underground explosions cause induced air pressure perturbations. The ionospheric technique utilizes the very strong air pressure pulse which is launched straight up above an underground explosion. When the pressure disturbance reaches the ionosphere, it becomes a 10 % pressure perturbation. Detection involves sending radio waves through the ionosphere with transmitters and recievers on the ground. Radar analysis yields interpretable signals. The near infrasound method detects the signal which is projected into the side lobes of the main signal. Both of the atmospheric methods were utilized on the monitoring of the NPE underground chemical explosion experiment. Results are described.

  7. Reduction Methods for Real-time Simulations in Hybrid Testing

    DEFF Research Database (Denmark)

    Andersen, Sebastian

    2016-01-01

    Hybrid testing constitutes a cost-effective experimental full scale testing method. The method was introduced in the 1960's by Japanese researchers, as an alternative to conventional full scale testing and small scale material testing, such as shake table tests. The principle of the method...... is performed on a glass fibre reinforced polymer composite box girder. The test serves as a pilot test for prospective real-time tests on a wind turbine blade. The Taylor basis is implemented in the test, used to perform the numerical simulations. Despite of a number of introduced errors in the real...... is to divide a structure into a physical substructure and a numerical substructure, and couple these in a test. If the test is conducted in real-time it is referred to as real time hybrid testing. The hybrid testing concept has developed significantly since its introduction in the 1960', both with respect...

  8. Atmospheric methods for nuclear test monitoring

    International Nuclear Information System (INIS)

    Simons, D.J.

    1995-01-01

    The U.S. DOE sponsored research investigating atmospheric infrasound as a means of detecting both atmospheric and underground nuclear tests. Various detection schemes were examined and were found to be effective for different situations. It has been discovered that an enhanced sensitivity is realizable for the very lowest frequency disturbances by detecting the infrasound at the top of the atmosphere using ratio sound techniques. These techniques are compared to more traditional measurement schemes

  9. Systematic evaluation of nondestructive testing methods

    International Nuclear Information System (INIS)

    Segal, Y.; Notea, A.; Segal, E.

    1977-01-01

    The main task of an NDT engineer is to select the best method, considering the cost-benefit value of different available systems and taking into account the special existing constraints. The aim of the paper is to suggest a tool that will enable characterization of measuring systems. The derivation of the characterization parameters and functions has to be general, i.e., suitable for all possible measuring methods, independent of their principle of operation. Quite often the properties measured during the NDT procedure are not the wanted ones, but there must be a correlation between the measured property and the performance of the product. One has to bear in mind that the ultimate choice between systems is not, in practice, just based on the mathematical optimization approach that is presented. Factors like cost-benefit, availability of trained manpower, service, real-time information, weight, volume, etc., may be crucial problems, and they may well dictate the final selection

  10. Towards the harmonization between National Forest Inventory and Forest Condition Monitoring. Consistency of plot allocation and effect of tree selection methods on sample statistics in Italy.

    Science.gov (United States)

    Gasparini, Patrizia; Di Cosmo, Lucio; Cenni, Enrico; Pompei, Enrico; Ferretti, Marco

    2013-07-01

    In the frame of a process aiming at harmonizing National Forest Inventory (NFI) and ICP Forests Level I Forest Condition Monitoring (FCM) in Italy, we investigated (a) the long-term consistency between FCM sample points (a subsample of the first NFI, 1985, NFI_1) and recent forest area estimates (after the second NFI, 2005, NFI_2) and (b) the effect of tree selection method (tree-based or plot-based) on sample composition and defoliation statistics. The two investigations were carried out on 261 and 252 FCM sites, respectively. Results show that some individual forest categories (larch and stone pine, Norway spruce, other coniferous, beech, temperate oaks and cork oak forests) are over-represented and others (hornbeam and hophornbeam, other deciduous broadleaved and holm oak forests) are under-represented in the FCM sample. This is probably due to a change in forest cover, which has increased by 1,559,200 ha from 1985 to 2005. In case of shift from a tree-based to a plot-based selection method, 3,130 (46.7%) of the original 6,703 sample trees will be abandoned, and 1,473 new trees will be selected. The balance between exclusion of former sample trees and inclusion of new ones will be particularly unfavourable for conifers (with only 16.4% of excluded trees replaced by new ones) and less for deciduous broadleaves (with 63.5% of excluded trees replaced). The total number of tree species surveyed will not be impacted, while the number of trees per species will, and the resulting (plot-based) sample composition will have a much larger frequency of deciduous broadleaved trees. The newly selected trees have-in general-smaller diameter at breast height (DBH) and defoliation scores. Given the larger rate of turnover, the deciduous broadleaved part of the sample will be more impacted. Our results suggest that both a revision of FCM network to account for forest area change and a plot-based approach to permit statistical inference and avoid bias in the tree sample

  11. Methods and models for the construction of weakly parallel tests

    NARCIS (Netherlands)

    Adema, J.J.; Adema, Jos J.

    1992-01-01

    Several methods are proposed for the construction of weakly parallel tests [i.e., tests with the same test information function (TIF)]. A mathematical programming model that constructs tests containing a prespecified TIF and a heuristic that assigns items to tests with information functions that are

  12. Further comments on the sequential probability ratio testing methods

    Energy Technology Data Exchange (ETDEWEB)

    Kulacsy, K. [Hungarian Academy of Sciences, Budapest (Hungary). Central Research Inst. for Physics

    1997-05-23

    The Bayesian method for belief updating proposed in Racz (1996) is examined. The interpretation of the belief function introduced therein is found, and the method is compared to the classical binary Sequential Probability Ratio Testing method (SPRT). (author).

  13. Harmonization versus Mutual Recognition

    DEFF Research Database (Denmark)

    Jørgensen, Jan Guldager; Schröder, Philipp

    The present paper examines trade liberalization driven by the coordination of product standards. For oligopolistic firms situated in separate markets that are initially sheltered by national standards, mutual recognition of standards implies entry and reduced profits at home paired with the oppor......The present paper examines trade liberalization driven by the coordination of product standards. For oligopolistic firms situated in separate markets that are initially sheltered by national standards, mutual recognition of standards implies entry and reduced profits at home paired...... countries and three firms, where firms first lobby for the policy coordination regime (harmonization versus mutual recognition), and subsequently, in case of harmonization, the global standard is auctioned among the firms. We discuss welfare effects and conclude with policy implications. In particular......, harmonized standards may fail to harvest the full pro-competitive effects from trade liberalization compared to mutual recognition; moreover, the issue is most pronounced in markets featuring price competition....

  14. Harmonic uniflow engine

    Science.gov (United States)

    Bennett, Charles L.

    2016-03-22

    A reciprocating-piston uniflow engine includes a harmonic oscillator inlet valve capable of oscillating at a resonant frequency for controlling the flow of working fluid into the engine. In particular, the inlet valve includes an inlet valve head and a spring arranged together as a harmonic oscillator so that the inlet valve head is moveable from an unbiased equilibrium position to a biased closed position occluding an inlet. When released, the inlet valve head undergoes a single oscillation past the equilibrium position to a maximum open position and returns to a biased return position close to the closed position to choke the flow and produce a pressure drop across the inlet valve causing the inlet valve to close. In other embodiments, the harmonic oscillator arrangement of the inlet valve enables the uniflow engine to be reversibly operated as a uniflow compressor.

  15. Fast harmonic field mapper

    International Nuclear Information System (INIS)

    Au, R.; Fowler, M.; Hanawa, H.; Riedel, J.; Qua, Z.G.

    1984-01-01

    In early 1983 it was decided to mount coils on arms separated by 120 degrees and buck them out so that the third harmonic dphi/dt component would be cancelled and thus the first and second field harmonics could be very accurately measured. The original intention was to do as others had done, namely, use fast ADC's to read the voltages, and computer process the result to get the Fourier components. However, because of the 100 to 1 dynamic range of the fast ADC's and the likelihood that noise would be a problem, the authors decided to do things differently. Using a fast Fourier transform analyzer was considered, but this instrument is very expensive, so they decided to use a completely electronic analog approach: The authors decided to use active bandpass filters to render the harmonic components

  16. Standard Test Method for Testing Nonmetallic Seal Materials by Immersion in a Simulated Geothermal Test Fluid

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers a procedure for a laboratory test for performing an initial evaluation (screening) of nonmetallic seal materials by immersion in a simulated geothermal test fluid. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6 and 11.7.

  17. Reliability of non-destructive testing methods

    International Nuclear Information System (INIS)

    Broekhoven, M.J.G.

    1988-01-01

    This contribution regards the results of an evaluation of the reliability of radiography (X-rays and gamma-rays), manual-, and mechanized/automated ultrasonic examination by generally accepted codes/rules, with respect to detection, characterization and sizing/localization of defects. The evaluation is based on the results of examinations, by a number of teams, of 30 test plates, 30 and 50 mm thickness, containing V,U, X and K-shaped welds each containing several types of imperfections (211) in total) typical for steel arc fusion welding, such as porosity, inclusions, lack of fusion or penetration and cracks. Besides, some results are presented obtained from research on advanced UT-techniques, viz. the time-of-flight-diffraction and flaw-tip deflection technique. (author)

  18. Reliability of non-destructive testing methods

    Energy Technology Data Exchange (ETDEWEB)

    Broekhoven, M J.G. [Ministry of Social Affairs, (Netherlands)

    1988-12-31

    This contribution regards the results of an evaluation of the reliability of radiography (X-rays and gamma-rays), manual-, and mechanized/automated ultrasonic examination by generally accepted codes/rules, with respect to detection, characterization and sizing/localization of defects. The evaluation is based on the results of examinations, by a number of teams, of 30 test plates, 30 and 50 mm thickness, containing V,U, X and K-shaped welds each containing several types of imperfections (211) in total) typical for steel arc fusion welding, such as porosity, inclusions, lack of fusion or penetration and cracks. Besides, some results are presented obtained from research on advanced UT-techniques, viz. the time-of-flight-diffraction and flaw-tip deflection technique. (author). 4 refs.

  19. Test equating, scaling, and linking methods and practices

    CERN Document Server

    Kolen, Michael J

    2014-01-01

    This book provides an introduction to test equating, scaling, and linking, including those concepts and practical issues that are critical for developers and all other testing professionals.  In addition to statistical procedures, successful equating, scaling, and linking involves many aspects of testing, including procedures to develop tests, to administer and score tests, and to interpret scores earned on tests. Test equating methods are used with many standardized tests in education and psychology to ensure that scores from multiple test forms can be used interchangeably.  Test scaling is the process of developing score scales that are used when scores on standardized tests are reported. In test linking, scores from two or more tests are related to one another. Linking has received much recent attention, due largely to investigations of linking similarly named tests from different test publishers or tests constructed for different purposes. In recent years, researchers from the education, psychology, and...

  20. Harmonic arbitrary waveform generator

    Science.gov (United States)

    Roberts, Brock Franklin

    2017-11-28

    High frequency arbitrary waveforms have applications in radar, communications, medical imaging, therapy, electronic warfare, and charged particle acceleration and control. State of the art arbitrary waveform generators are limited in the frequency they can operate by the speed of the Digital to Analog converters that directly create their arbitrary waveforms. The architecture of the Harmonic Arbitrary Waveform Generator allows the phase and amplitude of the high frequency content of waveforms to be controlled without taxing the Digital to Analog converters that control them. The Harmonic Arbitrary Waveform Generator converts a high frequency input, into a precision, adjustable, high frequency arbitrary waveform.

  1. General Criterion for Harmonicity

    Science.gov (United States)

    Proesmans, Karel; Vandebroek, Hans; Van den Broeck, Christian

    2017-10-01

    Inspired by Kubo-Anderson Markov processes, we introduce a new class of transfer matrices whose largest eigenvalue is determined by a simple explicit algebraic equation. Applications include the free energy calculation for various equilibrium systems and a general criterion for perfect harmonicity, i.e., a free energy that is exactly quadratic in the external field. As an illustration, we construct a "perfect spring," namely, a polymer with non-Gaussian, exponentially distributed subunits which, nevertheless, remains harmonic until it is fully stretched. This surprising discovery is confirmed by Monte Carlo and Langevin simulations.

  2. Linking high harmonics from gases and solids.

    Science.gov (United States)

    Vampa, G; Hammond, T J; Thiré, N; Schmidt, B E; Légaré, F; McDonald, C R; Brabec, T; Corkum, P B

    2015-06-25

    When intense light interacts with an atomic gas, recollision between an ionizing electron and its parent ion creates high-order harmonics of the fundamental laser frequency. This sub-cycle effect generates coherent soft X-rays and attosecond pulses, and provides a means to image molecular orbitals. Recently, high harmonics have been generated from bulk crystals, but what mechanism dominates the emission remains uncertain. To resolve this issue, we adapt measurement methods from gas-phase research to solid zinc oxide driven by mid-infrared laser fields of 0.25 volts per ångström. We find that when we alter the generation process with a second-harmonic beam, the modified harmonic spectrum bears the signature of a generalized recollision between an electron and its associated hole. In addition, we find that solid-state high harmonics are perturbed by fields so weak that they are present in conventional electronic circuits, thus opening a route to integrate electronics with attosecond and high-harmonic technology. Future experiments will permit the band structure of a solid to be tomographically reconstructed.

  3. Harmonic lasing in X-ray FELs

    Energy Technology Data Exchange (ETDEWEB)

    Schneidmiller, E.A.; Yurkov, M.V.

    2012-05-15

    Harmonic lasing in a free electron laser with a planar undulator (under the condition that the fundamental frequency is suppressed) might be a cheap and efficient way of extension of wavelength ranges of existing and planned X-ray FEL facilities. Contrary to nonlinear harmonic generation, harmonic lasing can provide much more intense, stable, and narrow-band FEL beam which is easier to handle due to the suppressed fundamental frequency. In this paper we perform a parametrization of the solution of the eigenvalue equation for lasing at odd harmonics, and present an explicit expression for FEL gain length, taking into account all essential effects. We propose and discuss methods for suppression of the fundamental harmonic. We also suggest a combined use of harmonic lasing and lasing at the retuned fundamental wavelength in order to reduce bandwidth and to increase brilliance of X-ray beam at saturation. Considering 3rd harmonic lasing as a practical example, we come to the conclusion that it is much more robust than usually thought, and can be widely used in the existing or planned X-ray FEL facilities. In particular, LCLS after a minor modification can lase to saturation at the 3rd harmonic up to the photon energy of 25-30 keV providing multi-gigawatt power level and narrow bandwidth. As for the European XFEL, harmonic lasing would allow to extend operating range (ultimately up to 100 keV), to reduce FEL bandwidth and to increase brilliance, to enable two-color operation for pump-probe experiments, and to provide more flexible operation at different electron energies. Similar improvements can be realized in other X-ray FEL facilities with gap-tunable undulators like FLASH II, SACLA, LCLS II, etc. Harmonic lasing can be an attractive option for compact X-ray FELs (driven by electron beams with a relatively low energy), allowing the use of the standard undulator technology instead of small-gap in-vacuum devices. Finally, in this paper we discover that in a part of the

  4. Harmonic Interaction Analysis in Grid-connected Converter using Harmonic State Space (HSS) Modeling

    DEFF Research Database (Denmark)

    Kwon, Jun Bum; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    research about the harmonic interaction. However, it is found that the Linear Time Invariant (LTI) based model analysis makes it difficult to analyze these phenomena because of the time-varying properties of the power electronic based systems. This paper investigates grid-connected converter by using......An increasing number of power electronic based Distributed Generation (DG) systems and loads generate not only characteristic harmonics but also unexpected harmonics. Several methods like impedance based analysis, which are derived from the conventional average model, are introduced to perform...

  5. Methods for testing of geometrical down-scaled rotor blades

    DEFF Research Database (Denmark)

    Branner, Kim; Berring, Peter

    further developed since then. Structures in composite materials are generally difficult and time consuming to test for fatigue resistance. Therefore, several methods for testing of blades have been developed and exist today. Those methods are presented in [1]. Current experimental test performed on full...

  6. Testing method for ceramic armour and bare ceramic tiles

    NARCIS (Netherlands)

    Carton, E.P.; Roebroeks, G.H.J.J.

    2016-01-01

    TNO developed an alternative, more configuration independent ceramic test method than the Depth-of-Penetration test method. In this alternative test ceramic tiles and ceramic based armour are evaluated as target without a semi-infinite backing layer. An energy approach is chosen to evaluate and rank

  7. Testing method for ceramic armor and bare ceramic tiles

    NARCIS (Netherlands)

    Carton, E.P.; Roebroeks, G.H.J.J.

    2014-01-01

    TNO has developed an alternative, more configuration independent ceramic test method than the standard Depth-of-Penetration test method. In this test ceramic tiles and ceramic based armor are evaluated as target without a semi-infinite backing layer. An energy approach is chosen to evaluate and rank

  8. Harmonic Analyzing of the Double PWM Converter in DFIG Based on Mathematical Model

    Directory of Open Access Journals (Sweden)

    Jing Liu

    2017-12-01

    Full Text Available Harmonic pollution of double fed induction generators (DFIGs has become a vital concern for its undesirable effects on power quality issues of wind generation systems and grid-connected system, and the double pulse width modulation (PWMconverter is one of the main harmonic sources in DFIGs. Thus the harmonic analysis of the converter in DFIGs is a necessary step to evaluate their harmonic pollution of DFIGs. This paper proposes a detailed harmonic modeling method to discuss the main harmonic components in a converter. In general the harmonic modeling could be divided into the low-order harmonic part (up to 30th order and the high-order harmonic part (greater than order 30 parts in general. The low-order harmonics are produced by the circuit topology and control algorithm, and the harmonic component will be different if the control strategy changes. The high-order harmonics are produced by the modulation of the switching function to the dc variable. In this paper, the low-order harmonic modeling is established according to the directions of power flow under the vector control (VC, and the high-order harmonic modeling is established by the switching function of space vector PWM and dc currents. Meanwhile, the simulations of harmonic a components in a converter are accomplished in a real time digital simulation system. The results indicate that the proposed modeling could effectively show the harmonics distribution of the converter in DFIGs.

  9. Integrated Data Collection Analysis (IDCA) Program - SSST Testing Methods

    Energy Technology Data Exchange (ETDEWEB)

    Sandstrom, Mary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Geoffrey W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Preston, Daniel N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pollard, Colin J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Warner, Kirstin F. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Remmers, Daniel L. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Sorensen, Daniel N. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Whinnery, LeRoy L. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Phillips, Jason J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Shelley, Timothy J. [Bureau of Alcohol, Tobacco and Firearms (ATF), Huntsville, AL (United States); Reyes, Jose A. [Applied Research Associates, Tyndall AFB, FL (United States); Hsu, Peter C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reynolds, John G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-03-25

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the methods used for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis during the IDCA program. These methods changed throughout the Proficiency Test and the reasons for these changes are documented in this report. The most significant modifications in standard testing methods are: 1) including one specified sandpaper in impact testing among all the participants, 2) diversifying liquid test methods for selected participants, and 3) including sealed sample holders for thermal testing by at least one participant. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study will suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.

  10. Comparing Harmonic Similarity Measures

    NARCIS (Netherlands)

    de Haas, W.B.; Robine, M.; Hanna, P.; Veltkamp, R.C.; Wiering, F.

    2010-01-01

    We present an overview of the most recent developments in polyphonic music retrieval and an experiment in which we compare two harmonic similarity measures. In contrast to earlier work, in this paper we specifically focus on the symbolic chord description as the primary musical representation and

  11. Harmonically excited orbital variations

    International Nuclear Information System (INIS)

    Morgan, T.

    1985-01-01

    Rephrasing the equations of motion for orbital maneuvers in terms of Lagrangian generalized coordinates instead of Newtonian rectangular cartesian coordinates can make certain harmonic terms in the orbital angular momentum vector more readily apparent. In this formulation the equations of motion adopt the form of a damped harmonic oscillator when torques are applied to the orbit in a variationally prescribed manner. The frequencies of the oscillator equation are in some ways unexpected but can nonetheless be exploited through resonant forcing functions to achieve large secular variations in the orbital elements. Two cases are discussed using a circular orbit as the control case: (1) large changes in orbital inclination achieved by harmonic excitation rather than one impulsive velocity change, and (2) periodic and secular changes to the longitude of the ascending node using both stable and unstable excitation strategies. The implications of these equations are also discussed for both artificial satellites and natural satellites. For the former, two utilitarian orbits are suggested, each exploiting a form of harmonic excitation. 5 refs

  12. Stress in Harmonic Serialism

    Science.gov (United States)

    Pruitt, Kathryn Ringler

    2012-01-01

    This dissertation proposes a model of word stress in a derivational version of Optimality Theory (OT) called Harmonic Serialism (HS; Prince and Smolensky 1993/2004, McCarthy 2000, 2006, 2010a). In this model, the metrical structure of a word is derived through a series of optimizations in which the "best" metrical foot is chosen…

  13. A Harmonic Motion Experiment

    Science.gov (United States)

    Gluck, P.; Krakower, Zeev

    2010-01-01

    We present a unit comprising theory, simulation and experiment for a body oscillating on a vertical spring, in which the simultaneous use of a force probe and an ultrasonic range finder enables one to explore quantitatively and understand many aspects of simple and damped harmonic motions. (Contains 14 figures.)

  14. Comparison of the EUCAST and CLSI Broth Microdilution Methods for Testing Isavuconazole, Posaconazole, and Amphotericin B against Molecularly Identified Mucorales Species.

    Science.gov (United States)

    Chowdhary, Anuradha; Singh, Pradeep Kumar; Kathuria, Shallu; Hagen, Ferry; Meis, Jacques F

    2015-12-01

    We compared EUCAST and CLSI antifungal susceptibility testing (AFST) methods for triazoles and amphotericin B against 124 clinical Mucorales isolates. The EUCAST method yielded MIC values 1- to 3-fold dilutions higher than those of the CLSI method for amphotericin B. The essential agreements between the two methods for triazoles were high, i.e., 99.1% (voriconazole), 98.3% (isavuconazole), and 87% (posaconazole), whereas it was significantly lower for amphotericin B (66.1%). Strategies for harmonization of the two methods for Mucorales AFST are warranted. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  15. Comparison of System Identification Methods using Ambient Bridge Test Data

    DEFF Research Database (Denmark)

    Andersen, P.; Brincker, Rune; Peeters, B.

    1999-01-01

    In this paper the performance of four different system identification methods is compared using operational data obtained from an ambient vibration test of the Swiss Z24 highway bridge. The four methods are the frequency domain based peak-picking methods, the polyreference LSCE method, the stocha......In this paper the performance of four different system identification methods is compared using operational data obtained from an ambient vibration test of the Swiss Z24 highway bridge. The four methods are the frequency domain based peak-picking methods, the polyreference LSCE method...

  16. Standard test methods for arsenic in uranium hexafluoride

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 These test methods are applicable to the determination of total arsenic in uranium hexafluoride (UF6) by atomic absorption spectrometry. Two test methods are given: Test Method A—Arsine Generation-Atomic Absorption (Sections 5-10), and Test Method B—Graphite Furnace Atomic Absorption (Appendix X1). 1.2 The test methods are equivalent. The limit of detection for each test method is 0.1 μg As/g U when using a sample containing 0.5 to 1.0 g U. Test Method B does not have the complete collection details for precision and bias data thus the method appears as an appendix. 1.3 Test Method A covers the measurement of arsenic in uranyl fluoride (UO2F2) solutions by converting arsenic to arsine and measuring the arsine vapor by flame atomic absorption spectrometry. 1.4 Test Method B utilizes a solvent extraction to remove the uranium from the UO2F2 solution prior to measurement of the arsenic by graphite furnace atomic absorption spectrometry. 1.5 Both insoluble and soluble arsenic are measured when UF6 is...

  17. Young children's harmonic perception.

    Science.gov (United States)

    Costa-Giomi, Eugenia

    2003-11-01

    Harmony and tonality are two of the most difficult elements for young children to perceive and manipulate and are seldom taught in the schools until the end of early childhood. Children's gradual harmonic and tonal development has been attributed to their cumulative exposure to Western tonal music and their increasing experiential knowledge of its rules and principles. Two questions that are relevant to this problem are: (1) Can focused and systematic teaching accelerate the learning of the harmonic/tonal principles that seem to occur in an implicit way throughout childhood? (2) Are there cognitive constraints that make it difficult for young children to perceive and/or manipulate certain harmonic and tonal principles? A series of studies specifically addressed the first question and suggested some possible answers to the second one. Results showed that harmonic instruction has limited effects on children's perception of harmony and indicated that the drastic improvement in the perception of implied harmony noted approximately at age 9 is due to development rather than instruction. I propose that young children's difficulty in perceiving implied harmony stems from their attention behaviors. Older children have less memory constraints and more strategies to direct their attention to the relevant cues of the stimulus. Younger children focus their attention on the melody, if present in the stimulus, and specifically on its concrete elements such as rhythm, pitch, and contour rather than its abstract elements such as harmony and key. The inference of the abstract harmonic organization of a melody required in the perception of implied harmony is thus an elusive task for the young child.

  18. ASTM test methods for composite characterization and evaluation

    Science.gov (United States)

    Masters, John E.

    1994-01-01

    A discussion of the American Society for Testing and Materials is given. Under the topic of composite materials characterization and evaluation, general industry practice and test methods for textile composites are presented.

  19. Standard test method for liquid impingement erosion using rotating apparatus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers tests in which solid specimens are eroded or otherwise damaged by repeated discrete impacts of liquid drops or jets. Among the collateral forms of damage considered are degradation of optical properties of window materials, and penetration, separation, or destruction of coatings. The objective of the tests may be to determine the resistance to erosion or other damage of the materials or coatings under test, or to investigate the damage mechanisms and the effect of test variables. Because of the specialized nature of these tests and the desire in many cases to simulate to some degree the expected service environment, the specification of a standard apparatus is not deemed practicable. This test method gives guidance in setting up a test, and specifies test and analysis procedures and reporting requirements that can be followed even with quite widely differing materials, test facilities, and test conditions. It also provides a standardized scale of erosion resistance numbers applicab...

  20. Symmetries in physics and harmonics

    International Nuclear Information System (INIS)

    Kolk, D.

    2006-01-01

    In this book the symmetries of elementary particles are described in relation to the rules of harmonics in music. The selection rules are described in connections with harmonic intervals. Also symmetry breaking is considered in this framework. (HSI)

  1. A Comparison of Two Approaches for the Ruggedness Testing of an Analytical Method

    International Nuclear Information System (INIS)

    Maestroni, Britt

    2016-01-01

    As part of an initiative under the “Red Analitica de Latino America y el Caribe” (RALACA) network the FAO/IAEA Food and Environmental Protection Laboratory validated a multi-residue method for pesticides in potato. One of the parameters to be assessed was the intra laboratory robustness or ruggedness. The objective of this work was to implement a worked example for RALACA laboratories to test for the robustness (ruggedness) of an analytical method. As a conclusion to this study, it is evident that there is a need for harmonization of the definition of the terms robustness/ruggedness, the limits, the methodology and the statistical treatment of the generated data. A worked example for RALACA laboratories to test for the robustness (ruggedness) of an analytical method will soon be posted on the RALACA website (www.red-ralaca.net). This study was carried out with collaborators from LVA (Austria), University of Antwerp (Belgium), University of Leuwen (The Netherlands), Universidad de la Republica (Uruguay) and Agilent technologies.

  2. The European Partnership for Alternative Approaches to Animal Testing (EPAA): promoting alternative methods in Europe and beyond.

    Science.gov (United States)

    Cozigou, Gwenole; Crozier, Jonathan; Hendriksen, Coenraad; Manou, Irene; Ramirez-Hernandez, Tzutzuy; Weissenhorn, Renate

    2015-03-01

    Here in we introduce the European Partnership for Alternative Approaches to Animal Testing (EPAA) and its activities, which are focused on international cooperation toward alternative methods. The EPAA is one of the leading organizations in Europe for the promotion of alternative approaches to animal testing. Its innovative public-private partnership structure enables a consensus-driven dialogue across 7 industry sectors to facilitate interaction between regulators and regulated stakeholders. Through a brief description of EPAA's activities and organizational structure, we first articulate the value of this collaboration; we then focus on 2 key projects driven by EPAA. The first project aims to address research gaps on stem cells for safety testing, whereas the second project strives for an approach toward demonstration of consistency in vaccine batch release testing. We highlight the growing need for harmonization of international acceptance and implementation of alternative approaches and for increased international collaboration to foster progress on nonanimal alternatives.

  3. A Teaching Method on Basic Chemistry for Freshman : Teaching Method with Pre-test and Post-test

    OpenAIRE

    立木, 次郎; 武井, 庚二

    2003-01-01

    This report deals with a teaching method on basic chemistry for freshman. This teaching method contains guidance and instruction to how to understand basic chemistry. Pre-test and post-test have been put into practice each time. Each test was returned to students at class in the following weeks.

  4. Harmonic Patterns in Forex Trading

    OpenAIRE

    Nemček, Sebastian

    2013-01-01

    This diploma thesis is committed to examination of validity of Harmonic Patterns in Forex trading. Scott Carney described existing and introduced new Harmonic Patterns in 1999 in his book Harmonic Trader. These patterns use the Fibonacci principle to analyze price action and to provide both bullish and bearish trading signals. The goal of this thesis is to find out whether harmonic trading strategy on selected pairs is profitable in FX market, which patterns are the most profitable and what i...

  5. Laguerre polynomials by a harmonic oscillator

    Science.gov (United States)

    Baykal, Melek; Baykal, Ahmet

    2014-09-01

    The study of an isotropic harmonic oscillator, using the factorization method given in Ohanian's textbook on quantum mechanics, is refined and some collateral extensions of the method related to the ladder operators and the associated Laguerre polynomials are presented. In particular, some analytical properties of the associated Laguerre polynomials are derived using the ladder operators.

  6. Laguerre polynomials by a harmonic oscillator

    International Nuclear Information System (INIS)

    Baykal, Melek; Baykal, Ahmet

    2014-01-01

    The study of an isotropic harmonic oscillator, using the factorization method given in Ohanian's textbook on quantum mechanics, is refined and some collateral extensions of the method related to the ladder operators and the associated Laguerre polynomials are presented. In particular, some analytical properties of the associated Laguerre polynomials are derived using the ladder operators. (paper)

  7. Coherent harmonic production using a two-section undulator FEL

    Energy Technology Data Exchange (ETDEWEB)

    Jaroszynski, D.A. [Commissariat a l`Energie, Bruyeres-le-Chatel (France); Prazeres, R.; Glotin, F. [Centre Universitaire Paris-Sud (France)] [and others

    1995-12-31

    We present measurements and a theoretical analysis of a new method of generating harmonic radiation in a free-electron laser oscillator with a two section undulator in a single optical cavity. To produce coherent harmonic radiation the undulator is arranged so that the downstream undulator section resonance frequency matches a harmonic of the upstream undulator. Both the fundamental and the harmonic optical fields evolve in the same optical cavity and are coupled out with different extraction fractions using a hole in one of the cavity mirrors. We present measurements that show that the optical power at the second and third harmonic can be enhanced by more than an order of magnitude in this fundamental/harmonic configuration. We compare the production of harmonic radiation of a two sectioned fundamental/harmonic undulator with that produced from a FEL operating at its highest efficiency with a step-tapered undulator, where the bunching at the end of the first section is very large. We examine, the dependence of the harmonic power on the intracavity power by adjusting the optical cavity desynchronism, {delta}L. We also examine the evolution of the fundamental and harmonic powers as a function of cavity roundtrip number to evaluate the importance of the small signal gain at the harmonic. We compare our measurements with predictions of a multi-electron numerical model that follows the evolution of fundamental and harmonic power to saturation. This fundamental/harmonic mode, of operation of the FEL may have useful applications in the production of coherent X-ray and VUV radiation, a spectral range where high reflectivity optical cavity mirrors are difficult or impossible to manufacture.

  8. TESTING METHODS FOR MECHANICALLY IMPROVED SOILS: RELIABILITY AND VALIDITY

    Directory of Open Access Journals (Sweden)

    Ana Petkovšek

    2017-10-01

    Full Text Available A possibility of in-situ mechanical improvement for reducing the liquefaction potential of silty sands was investigated by using three different techniques: Vibratory Roller Compaction, Rapid Impact Compaction (RIC and Soil Mixing. Material properties at all test sites were investigated before and after improvement with the laboratory and the in situ tests (CPT, SDMT, DPSH B, static and dynamic load plate test, geohydraulic tests. Correlation between the results obtained by different test methods gave inconclusive answers.

  9. Harmonic Distortion of Rectifier Topologies for Adjustable Speed Drives

    DEFF Research Database (Denmark)

    Hansen, Steffan

    This thesis deals with the harmonic distortion of the diode rectifier and a number of alternative rectifier topologies for adjustable speed drives. The main intention of this thesis is to provide models and tools that allow easy prediction of the harmonic distortion of ASD’s in a given system...... rectifier are presented. The first level is an ideal model where the diode rectifier basically is treated as an independent (harmonic) current source. The second level is an empirical model, where simulated (or measured) values of the harmonic currents of the diode rectifier for different parameters......-angle of the individual harmonic currents of different diode rectifier types is analyzed. Four selected rectifier topologies with a high input power factor are presented. It is shown that using ac- or dc-coils is a very simple and efficient method to reduce the harmonic currents compared to the basic diode rectifier...

  10. Development and Validation of a Dissolution Test Method for ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a dissolution test method for dissolution release of artemether and lumefantrine from tablets. Methods: A single dissolution method for evaluating the in vitro release of artemether and lumefantrine from tablets was developed and validated. The method comprised of a dissolution medium of ...

  11. Generating and testing methods for consumer-oriented product development

    International Nuclear Information System (INIS)

    2001-10-01

    In order to obtain a good insight into various design methods that can be used by product developers to enable them to develop and test useful domotics products (domotics: intelligent systems for the home), an inventory has been made of the methods used in the Netherlands. The inventory is directed at two categories of methods: (1) Methods of getting better acquainted with the user and/or the problem, and of generating novel solutions: generative methods; and (2) Methods of assessing solutions (through various phases of the designing process): testing methods. The first category of methods concentrates on the designing process. In other words: how can the designer realise as much as possible of the workability of (domotics) products during the designing process? The second category aims at testing a design (in whatever shape: drawing, prototype, functional computer animation, etc.) through its users. These are methods of assessing a design at various stages of the designing process [nl

  12. Harmonic Analysis and Active Filtering in Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay Kumar; Freijedo Fernandez, Francisco Daniel; Guerrero, Josep M.

    2015-01-01

    Due to presence of long high voltage cable networks, and power transformers for the grid connection, the offshore wind power plants (OWPPs) are susceptible to harmonic distortion and resonances. The grid connection of OWPP should not cause the harmonic distortion beyond the permissible limits...... at the point of common coupling (PCC). The resonance conditions should be avoided in all cases. This paper describes the harmonic analysis techniques applied on an OWPP network model. A method is proposed to estimate the harmonic current compensation from a shunt-connected active power filter to mitigate...

  13. Analysing harmonic motions with an iPhone’s magnetometer

    Science.gov (United States)

    Yavuz, Ahmet; Kağan Temiz, Burak

    2016-05-01

    In this paper, we propose an experiment for analysing harmonic motion using an iPhone’s (or iPad’s) magnetometer. This experiment consists of the detection of magnetic field variations obtained from an iPhone’s magnetometer sensor. A graph of harmonic motion is directly displayed on the iPhone’s screen using the Sensor Kinetics application. Data from this application was analysed with Eureqa software to establish the equation of the harmonic motion. Analyses show that the use of an iPhone’s magnetometer to analyse harmonic motion is a practical and effective method for small oscillations and frequencies less than 15-20 Hz.

  14. Validation Techniques of network harmonic models based on switching of a series linear component and measuring resultant harmonic increments

    DEFF Research Database (Denmark)

    Wiechowski, Wojciech Tomasz; Lykkegaard, Jan; Bak, Claus Leth

    2007-01-01

    In this paper two methods of validation of transmission network harmonic models are introduced. The methods were developed as a result of the work presented in [1]. The first method allows calculating the transfer harmonic impedance between two nodes of a network. Switching a linear, series network......, as for example a transmission line. Both methods require that harmonic measurements performed at two ends of the disconnected element are precisely synchronized....... are used for calculation of the transfer harmonic impedance between the nodes. The determined transfer harmonic impedance can be used to validate a computer model of the network. The second method is an extension of the fist one. It allows switching a series element that contains a shunt branch...

  15. Harmonic mitigation in islanded microgrids by inverter-interfaced distributed energy resource

    Energy Technology Data Exchange (ETDEWEB)

    Xiongfei Wang

    2012-10-15

    primary droop controllers integrated with virtual output impedance loops and the secondary controllers enabled by the low-bandwidth communication. With the chosen control options of DER inverters, the circulating current characteristics in the droop-controlled parallel three-phase DER inverters are analysed. It is found that the circulating current not only consists of the Positive-Sequence Circulating Current (PSCC) but also contains the Negative-Sequence Circulating Current (NSCC) even when feeding linear balanced loads. It is shown that the presence of the NSCC deteriorates the current quality of inverters and results in unbalanced voltage distortion at certain buses of an islanded microgrid. In order to reduce the NSCC, an improved virtual output impedance loop is proposed, where a negative-sequence virtual resistance is introduced based on the detection of the negative-sequence output current. Moreover, to adapt to the variation of unbalanced loads, a dynamically-tuned negative-sequence resistance is developed. Thus, an autonomous NSCC control that is more suitable for the scattered DER units is achieved and validated via a series of laboratory tests. Under the built islanded microgrid, the control methods of DER inverters for active harmonic conditioning are investigated. Two autonomous harmonic current filtering and resonance damping approaches, i.e. the Resistive-Active Power Filter (R-APF)-based method and the virtual output resistance scheme, are evaluated. It has been found that the large grid-side inductances of DER inverters may lead to either underdamped or aggravated harmonic voltages in the islanded microgrid. To address such a challenge, a Variable Harmonic Impedance (VHI) concept is proposed, where positive resistances and negative inductances are synthesized at the dominant harmonic frequencies. Two case studies, including the single grid-interactive DER inverter and the parallel DER inverters, are carried out. Simulation and laboratory test results are

  16. Comparison of test methods for mould growth in buildings

    DEFF Research Database (Denmark)

    Bonderup, Sirid; Gunnarsen, Lars Bo; Knudsen, Sofie Marie

    2016-01-01

    renovation needs. This is of importance when hidden surface testing would require destructive measures and subsequent renovation. After identifying available methods on the Danish market for assessing mould growth in dwellings, a case study was conducted to test the usefulness of the methods in four......The purpose of this work is to compare a range of test methods and kits for assessing whether a building structure is infested by mould fungi. A further purpose of this work is to evaluate whether air-based methods for sampling fungal emissions provide information qualifying decisions concerning...... methods measure different aspects relating to mould growth and vary in selectivity and precision. The two types of air samples indicated low levels of mould growth, even where the results of the other methods indicated high to moderate growth. With methods based on culture and DNA testing some differences...

  17. Comparative study of fracture mechanical test methods for concrete

    DEFF Research Database (Denmark)

    Østergaard, Lennart; Olesen, John Forbes

    2004-01-01

    and the interpretation, i.e. the analysis needed to extract the stress-crack opening relationship, the fracture energy etc. Experiments are carried out with each test configuration using mature, high performance concrete. The results show that the UTT is a highly complicated test, which only under very well controlled...... circumstances will yield the true fracture mechanical properties. It is also shown that both the three point bending test and the WST are well-suited substitutes for the uniaxial tension test.......This paper describes and compares three different fracture mechanical test methods; the uniaxial tension test (UTT), the three point bending test (TPBT) and the wedge splitting test (WST). Potentials and problems with the test methods will be described with regard to the experiment...

  18. The Harmonization of Accounting

    Directory of Open Access Journals (Sweden)

    Hajnal Noémi

    2017-11-01

    Full Text Available The development and configuration of the regulatory framework of the accounting systems in Romania and Hungary took place in different ways. Among the reasons for the diversities in these countries’ accounting systems, the following can be certainly mentioned: different purposes of taxation, legal structure, the accountancy’s connection with the corporate law and family law, diversification on corporate financing policy, and cultural heterogeneity. Both countries quickly caught up with the international accounting harmonization standards. The adaptation of the international accounting standards has many advantages and disadvantages; these have been discussed in several previous researches. This paper aims at comparing the Romanian and Hungarian states’ accounting regulations from the early 1990s, which were implemented in order to harmonize the states’ accountancy regulations with the international standards, and their impact on the economy, based on secondary analysis.

  19. Testing and Validation of the Dynamic Interia Measurement Method

    Science.gov (United States)

    Chin, Alexander; Herrera, Claudia; Spivey, Natalie; Fladung, William; Cloutier, David

    2015-01-01

    This presentation describes the DIM method and how it measures the inertia properties of an object by analyzing the frequency response functions measured during a ground vibration test (GVT). The DIM method has been in development at the University of Cincinnati and has shown success on a variety of small scale test articles. The NASA AFRC version was modified for larger applications.

  20. 40 CFR 76.15 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Test methods and procedures. 76.15 Section 76.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.15 Test methods and procedures. (a) The...

  1. Methods of Usability Testing in Libraries Web Sites

    Directory of Open Access Journals (Sweden)

    Eman Fawzy

    2006-03-01

    Full Text Available A Study about libraries' web sites evaluation, that is the Usability, the study talking about methods of usability testing and define it, and its important in web sites evaluation, then details the methods of usability: questionnaire, core groups, testing experimental model, cards arrangement, and composed evaluation.

  2. Nondestructive testing methods for 55-gallon, waste storage drums

    International Nuclear Information System (INIS)

    Ferris, R.H.; Hildebrand, B.P.; Hockey, R.L.; Riechers, D.M.; Spanner, J.C.; Duncan, D.R.

    1993-06-01

    The Westinghouse Hanford Company (WHC) authorized Pacific Northwest Laboratory (PNL) to conduct a feasibility study to identify promising nondestructive testing (NDT) methods for detecting general and localized (both pitting and pinhole) corrosion in the 55-gal drums that are used to store solid waste materials at the Hanford Site. This document presents results obtained during a literature survey, identifies the relevant reference materials that were reviewed, provides a technical description of the methods that were evaluated, describes the laboratory tests that were conducted and their results, identifies the most promising candidate methods along with the rationale for these selections, and includes a work plan for recommended follow-on activities. This report contains a brief overview and technical description for each of the following NDT methods: magnetic testing techniques; eddy current testing; shearography; ultrasonic testing; radiographic computed tomography; thermography; and leak testing with acoustic detection

  3. Test methods for protective footwear against AP mine blast

    NARCIS (Netherlands)

    Cronin, D.S.; Williams, K.; Bass, C.R.; Magnan, P.; Dosquet, F.; Bergeron, D.M.; Bree, J.L.M.J. van

    2003-01-01

    The testing and development of protective footwear for anti-personnel landmine blast threats is of great importance to civilian and military deminers, and peacekeepers. This study will review the wide range of test methods that have been developed by NATO countries to test footwear against the

  4. Application of Bayesian Methods for Detecting Fraudulent Behavior on Tests

    Science.gov (United States)

    Sinharay, Sandip

    2018-01-01

    Producers and consumers of test scores are increasingly concerned about fraudulent behavior before and during the test. There exist several statistical or psychometric methods for detecting fraudulent behavior on tests. This paper provides a review of the Bayesian approaches among them. Four hitherto-unpublished real data examples are provided to…

  5. Evaluation of methods to leak test sealed radiation sources

    International Nuclear Information System (INIS)

    Arbeau, N.D.; Scott, C.K.

    1987-04-01

    The methods for the leak testing of sealed radiation sources were reviewed. One hundred and thirty-one equipment vendors were surveyed to identify commercially available leak test instruments. The equipment is summarized in tabular form by radiation type and detector type for easy reference. The radiation characteristics of the licensed sources were reviewed and summarized in a format that can be used to select the most suitable detection method. A test kit is proposed for use by inspectors when verifying a licensee's test procedures. The general elements of leak test procedures are discussed

  6. Harmonic and geometric analysis

    CERN Document Server

    Citti, Giovanna; Pérez, Carlos; Sarti, Alessandro; Zhong, Xiao

    2015-01-01

    This book presents an expanded version of four series of lectures delivered by the authors at the CRM. Harmonic analysis, understood in a broad sense, has a very wide interplay with partial differential equations and in particular with the theory of quasiconformal mappings and its applications. Some areas in which real analysis has been extremely influential are PDE's and geometric analysis. Their foundations and subsequent developments made extensive use of the Calderón–Zygmund theory, especially the Lp inequalities for Calderón–Zygmund operators (Beurling transform and Riesz transform, among others) and the theory of Muckenhoupt weights.  The first chapter is an application of harmonic analysis and the Heisenberg group to understanding human vision, while the second and third chapters cover some of the main topics on linear and multilinear harmonic analysis. The last serves as a comprehensive introduction to a deep result from De Giorgi, Moser and Nash on the regularity of elliptic partial differen...

  7. Stopping test of iterative methods for solving PDE

    International Nuclear Information System (INIS)

    Wang Bangrong

    1991-01-01

    In order to assure the accuracy of the numerical solution of the iterative method for solving PDE (partial differential equation), the stopping test is very important. If the coefficient matrix of the system of linear algebraic equations is strictly diagonal dominant or irreducible weakly diagonal dominant, the stopping test formulas of the iterative method for solving PDE is proposed. Several numerical examples are given to illustrate the applications of the stopping test formulas

  8. 40 CFR 63.344 - Performance test requirements and test methods.

    Science.gov (United States)

    2010-07-01

    ... electroplating tanks or chromium anodizing tanks. The sampling time and sample volume for each run of Methods 306... Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test... Emissions From Decorative and Hard Chromium Electroplating and Anodizing Operations,” appendix A of this...

  9. Third harmonic generation of shear horizontal guided waves propagation in plate-like structures

    Energy Technology Data Exchange (ETDEWEB)

    Li, Wei Bin [School of Aerospace Engineering, Xiamen University, Xiamen (China); Xu, Chun Guang [School of Mechanical Engineering, Beijing Institute of Technology, Beijing (China); Cho, Youn Ho [School of Mechanical Engineering, Pusan National University, Busan (Korea, Republic of)

    2016-04-15

    The use of nonlinear ultrasonics wave has been accepted as a promising tool for monitoring material states related to microstructural changes, as it has improved sensitivity compared to conventional non-destructive testing approaches. In this paper, third harmonic generation of shear horizontal guided waves propagating in an isotropic plate is investigated using the perturbation method and modal analysis approach. An experimental procedure is proposed to detect the third harmonics of shear horizontal guided waves by electromagnetic transducers. The strongly nonlinear response of shear horizontal guided waves is measured. The accumulative growth of relative acoustic nonlinear response with an increase of propagation distance is detected in this investigation. The experimental results agree with the theoretical prediction, and thus providing another indication of the feasibility of using higher harmonic generation of electromagnetic shear horizontal guided waves for material characterization.

  10. Evaluation of Test Method for Solar Collector Efficiency

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    The test method of the standard EN12975-2 (European Committee for Standardization, 2004) is used by European test laboratories to determine the efficiency of solar collectors. In the test methods the mean solar collector fluid temperature in the solar collector, Tm is determined by the approximat...... and the sky temperature. Based on the investigations, recommendations for change of the test methods and test conditions are considered. The investigations are carried out within the NEGST (New Generation of Solar Thermal Systems) project financed by EU.......The test method of the standard EN12975-2 (European Committee for Standardization, 2004) is used by European test laboratories to determine the efficiency of solar collectors. In the test methods the mean solar collector fluid temperature in the solar collector, Tm is determined by the approximated...... equation where Tin is the inlet temperature to the collector and Tout is the outlet temperature from the collector. The specific heat of the solar collector fluid is in the test method as an approximation determined as a constant equal to the specific heat of the solar collector fluid at the temperature Tm...

  11. Study of test methods for radionuclide migration in aerated zone

    International Nuclear Information System (INIS)

    Li Shushen; Guo Zede; Wang Zhiming

    1993-01-01

    Aerated zone is an important natural barrier against transport of radionuclides released from disposal facilities of LLRW. This paper introduces study methods for radionuclide migration in aerated zone, including determination of water movement, laboratory simulation test, and field tracing test. For one purpose, results obtained with different methods are compared. These methods have been used in a five-year cooperative research project between CIRP and JAERI for an establishment of methodology for safety assessment on shallow land disposal of LLRW

  12. Harmonization of multi-site diffusion tensor imaging data.

    Science.gov (United States)

    Fortin, Jean-Philippe; Parker, Drew; Tunç, Birkan; Watanabe, Takanori; Elliott, Mark A; Ruparel, Kosha; Roalf, David R; Satterthwaite, Theodore D; Gur, Ruben C; Gur, Raquel E; Schultz, Robert T; Verma, Ragini; Shinohara, Russell T

    2017-11-01

    Diffusion tensor imaging (DTI) is a well-established magnetic resonance imaging (MRI) technique used for studying microstructural changes in the white matter. As with many other imaging modalities, DTI images suffer from technical between-scanner variation that hinders comparisons of images across imaging sites, scanners and over time. Using fractional anisotropy (FA) and mean diffusivity (MD) maps of 205 healthy participants acquired on two different scanners, we show that the DTI measurements are highly site-specific, highlighting the need of correcting for site effects before performing downstream statistical analyses. We first show evidence that combining DTI data from multiple sites, without harmonization, may be counter-productive and negatively impacts the inference. Then, we propose and compare several harmonization approaches for DTI data, and show that ComBat, a popular batch-effect correction tool used in genomics, performs best at modeling and removing the unwanted inter-site variability in FA and MD maps. Using age as a biological phenotype of interest, we show that ComBat both preserves biological variability and removes the unwanted variation introduced by site. Finally, we assess the different harmonization methods in the presence of different levels of confounding between site and age, in addition to test robustness to small sample size studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Evaluation of snubber functional test methods: Tier 1

    International Nuclear Information System (INIS)

    Brown, D.P.

    1993-07-01

    The objective of the research is to establish technical bases in support of efforts on the part of the Snubber Utility Group (SNUG) and the Subsection ISTD Working Group of the ASME O ampersand M Code in developing guidelines and methodologies for snubber functional testing to ensure that snubbers are tested in a manner that ensures reliable and meaningful test results. The methodology used in this research includes both a review of available industry information as well as the testing of different snubber models using various test machines. Information is provided pertaining to current industry practices in regard to snubber testing including recommended test procedures, technical description of various test machines, and the number and types of snubbers used in the nuclear power industry. A review of previous test methodology research conducted by the Snubber Utility Group is also included. The effects of variations in controllable test parameters on snubber test results are discussed. Also included are the results of confirmatory tests in which various snubber models were tested using various test machines. Recommendations are provided for standard test methods to be included in Subsection ISTD of the ASME O ampersand M Code [4]. General information and recommendations are provided that may be used by utility personnel in specifying snubber test equipment that is most suited for plant-specific needs as well as information that may be effectively used in the review and interpretation of test results

  14. Variational Integrals of a Class of Nonhomogeneous -Harmonic Equations

    Directory of Open Access Journals (Sweden)

    Guanfeng Li

    2014-01-01

    Full Text Available We introduce a class of variational integrals whose Euler equations are nonhomogeneous -harmonic equations. We investigate the relationship between the minimization problem and the Euler equation and give a simple proof of the existence of some nonhomogeneous -harmonic equations by applying direct methods of the calculus of variations. Besides, we establish some interesting results on variational integrals.

  15. Vitrigel-eye irritancy test method using HCE-T cells.

    Science.gov (United States)

    Yamaguchi, Hiroyuki; Kojima, Hajime; Takezawa, Toshiaki

    2013-10-01

    We previously reported that the time-dependent relative changes of transepithelial electrical resistance (TEER) after exposing four different chemicals to a human corneal epithelium (HCE) model were well correlated to the potential of ocular irritancy. Meanwhile, we recently developed a collagen vitrigel membrane (CVM) chamber possessing a scaffold composed of high-density collagen fibrils equivalent to connective tissues in vivo as a three-dimensional culture tool. The CVM chamber is useful for biomedical assays and immunohistology using cryosections that are inappropriate to be performed using the conventional Millicell chamber with a polyethylene terephthalate membrane. In this study, we aimed to develop a new eye irritancy test (EIT) method called "Vitrigel-EIT method" that can facilitate to briefly and accurately estimate the widespread irritancy of test chemicals by applying the TEER assay system to a HCE model fabricated in the CVM chamber. HCE-T cells (a HCE-derived cell strain) were cultured in the CVM chamber for 6 days, and consequently, the Vitrigel-HCE model possessing the following characteristics of HCE in vivo was formed: six cell layers with specific protein expressions and their barrier function. Time-dependent profiles of TEER values after exposing 30 test chemicals to the HCE model were converted into the scores of three indexes (time lag, intensity, and plateau level), and each chemical was successfully classified into irritant or nonirritant category by utilizing the criteria for the indexes, resulting in the excellent correlation with Globally Harmonized System of Classification and Labelling of Chemicals (GHS) classification (sensitivity: 100%, specificity: 75%, accuracy: 90%). These data suggest that the widespread eye irritancy of chemicals can be predicted without false negatives by the Vitrigel-EIT method. Interestingly, the disruption of tight junctions was immunohistologically observed after exposing not only irritants but also three

  16. A Teaching Method on Basic Chemistry for Freshman (II) : Teaching Method with Pre-test and Post-test

    OpenAIRE

    立木, 次郎; 武井, 庚二

    2004-01-01

    This report deals with review of a teaching method on basic chemistry for freshman in this first semester. We tried to review this teaching method with pre-test and post-test by means of the official and private questionnaires. Several hints and thoughts on teaching skills are obtained from this analysis.

  17. Harmonic analysis in integrated energy system based on compressed sensing

    International Nuclear Information System (INIS)

    Yang, Ting; Pen, Haibo; Wang, Dan; Wang, Zhaoxia

    2016-01-01

    Highlights: • We propose a harmonic/inter-harmonic analysis scheme with compressed sensing theory. • Property of sparseness of harmonic signal in electrical power system is proved. • The ratio formula of fundamental and harmonic components sparsity is presented. • Spectral Projected Gradient-Fundamental Filter reconstruction algorithm is proposed. • SPG-FF enhances the precision of harmonic detection and signal reconstruction. - Abstract: The advent of Integrated Energy Systems enabled various distributed energy to access the system through different power electronic devices. The development of this has made the harmonic environment more complex. It needs low complexity and high precision of harmonic detection and analysis methods to improve power quality. To solve the shortages of large data storage capacities and high complexity of compression in sampling under the Nyquist sampling framework, this research paper presents a harmonic analysis scheme based on compressed sensing theory. The proposed scheme enables the performance of the functions of compressive sampling, signal reconstruction and harmonic detection simultaneously. In the proposed scheme, the sparsity of the harmonic signals in the base of the Discrete Fourier Transform (DFT) is numerically calculated first. This is followed by providing a proof of the matching satisfaction of the necessary conditions for compressed sensing. The binary sparse measurement is then leveraged to reduce the storage space in the sampling unit in the proposed scheme. In the recovery process, the scheme proposed a novel reconstruction algorithm called the Spectral Projected Gradient with Fundamental Filter (SPG-FF) algorithm to enhance the reconstruction precision. One of the actual microgrid systems is used as simulation example. The results of the experiment shows that the proposed scheme effectively enhances the precision of harmonic and inter-harmonic detection with low computing complexity, and has good

  18. 40 CFR 63.1257 - Test methods and compliance procedures.

    Science.gov (United States)

    2010-07-01

    ... chemical engineering principles, measurable process parameters, or physical or chemical laws or properties... flow rate and concentration; temperature; and the reaction kinetics of the constituents with the... Method 8260 or 8270 in “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA...

  19. Harmonics in large offshore wind farms

    DEFF Research Database (Denmark)

    Kocewiak, Lukasz Hubert

    and nature of various harmonic components. A comprehensive comparison of harmonic voltages and currents based on probability distribution estimation and appropriate statistics calculation (mean, variance, probability density function, etc.) is applied. Such approach gives a better overview and comparison...... and analysis, and ϐinally ending up on modelling and models application. Different aspects of validation in time domain, frequency domain, and by application of statistical methods are mentioned in relation to respective problems. Measurements constitute a core part in industry-oriented research. Due...... that it is of great importance to know the nature of generated harmonics in large offshore wind farms in order to apply the most suitable data processing technique. Time-frequency analysis based on multiresolution wavelet transform is used in order to perform time-frequency domain analysis helpful to distinguish...

  20. Standard test method for galling resistance of material couples

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers a laboratory test that ranks the galling resistance of material couples using a quantitative measure. Bare metals, alloys, nonmetallic materials, coatings, and surface modified materials may be evaluated by this test method. 1.2 This test method is not designed for evaluating the galling resistance of material couples sliding under lubricated conditions, because galling usually will not occur under lubricated sliding conditions using this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  1. New methods of testing nonlinear hypothesis using iterative NLLS estimator

    Science.gov (United States)

    Mahaboob, B.; Venkateswarlu, B.; Mokeshrayalu, G.; Balasiddamuni, P.

    2017-11-01

    This research paper discusses the method of testing nonlinear hypothesis using iterative Nonlinear Least Squares (NLLS) estimator. Takeshi Amemiya [1] explained this method. However in the present research paper, a modified Wald test statistic due to Engle, Robert [6] is proposed to test the nonlinear hypothesis using iterative NLLS estimator. An alternative method for testing nonlinear hypothesis using iterative NLLS estimator based on nonlinear hypothesis using iterative NLLS estimator based on nonlinear studentized residuals has been proposed. In this research article an innovative method of testing nonlinear hypothesis using iterative restricted NLLS estimator is derived. Pesaran and Deaton [10] explained the methods of testing nonlinear hypothesis. This paper uses asymptotic properties of nonlinear least squares estimator proposed by Jenrich [8]. The main purpose of this paper is to provide very innovative methods of testing nonlinear hypothesis using iterative NLLS estimator, iterative NLLS estimator based on nonlinear studentized residuals and iterative restricted NLLS estimator. Eakambaram et al. [12] discussed least absolute deviation estimations versus nonlinear regression model with heteroscedastic errors and also they studied the problem of heteroscedasticity with reference to nonlinear regression models with suitable illustration. William Grene [13] examined the interaction effect in nonlinear models disused by Ai and Norton [14] and suggested ways to examine the effects that do not involve statistical testing. Peter [15] provided guidelines for identifying composite hypothesis and addressing the probability of false rejection for multiple hypotheses.

  2. Nuclear EMP: stripline test method for measuring transfer impedance

    International Nuclear Information System (INIS)

    Miller, J.S.

    1975-11-01

    A method for measuring the transfer impedance of flat metal joints for frequencies to 100 MHz has been developed which makes use of striplines. The stripline method, which has similarities to the quadraxial method used for cylindrical components, is described and sets of test results are given. The transfer impedance of a simple joint is modeled as a spurious hyperbolic curve, and a close curve fit to transfer impedance test data from various samples is demonstrated for both the stripline and the quadraxial methods. Validity checks of the test data are discussed using the curve model and other criteria. The method was developed for testing riveted joints which form the avionics bays on B-1s. The joints must provide shielding from EMP currents

  3. Perception of the pitch of unresolved harmonics by 3- and 7-month-old human infants.

    Science.gov (United States)

    Lau, Bonnie K; Werner, Lynne A

    2014-08-01

    Three-month-olds discriminate resolved harmonic complexes on the basis of missing fundamental (MF) pitch. In view of reported difficulty in discriminating unresolved complexes at 7 months and striking changes in the organization of the auditory system during early infancy, infants' ability to discriminate unresolved complexes is of some interest. This study investigated the ability of 3-month-olds, 7-month-olds, and adults to discriminate the pitch of unresolved harmonic complexes using an observer-based method. Stimuli were MF complexes bandpass filtered with a -12 dB/octave slope, combined in random phase, presented at 70 dB sound pressure level (SPL) for 650 ms with a 50 ms rise/fall with a pink noise at 65 dB SPL. The conditions were (1) "LOW" unresolved harmonics (2500-4500 Hz) based on MFs of 160 and 200 Hz and (2) "HIGH" unresolved harmonics (4000-6000 Hz) based on MFs of 190 and 200 Hz. To demonstrate MF discrimination, participants had to ignore spectral changes in complexes with the same fundamental and respond only when the fundamental changed. Nearly all infants tested categorized complexes by MF pitch suggesting discrimination of pitch extracted from unresolved harmonics by 3 months. Adults also categorized the complexes by MF pitch, although musically trained adults were more successful than musically untrained adults.

  4. Test Methods for Telemetry Systems and Subsystems Volume 1: Test Methods for Vehicle Telemetry Systems

    Science.gov (United States)

    2012-05-01

    Noise Test .......................................................................... 5-106 5.29 Transmitter Bit Error Probability ( BEP ) versus Eb/N0...modulation BC Bus controller BCD Binary coded decimal BCM Bit code modulation BEP Bit error probability BER Bit error rate BPF Band-pass filter BW...5.29 Transmitter Phase Noise Test X X 5.30 Transmitter Bit Error Probability ( BEP ) versus Eb/N0 X (5) X (5) X X X X 5.31 Software

  5. The influence of technical testing methods on perceptions of constructions

    International Nuclear Information System (INIS)

    Oestberg, Gustaf

    2002-01-01

    In principle, methods of testing the reliability and safety of constructions are designed with the aim of representing critical conditions for their use. Because of variations within technical systems, including the one for which a certain test was once developed, the validity of the method also varies. The adoption of a standardized test for different applications had to be based on the assumption that the test deals adequately with a real situation. As a consequence of this acceptance of a trustworthy relationship between test and reality, an imprint of the former on the latter occurs. This effect may even cause the perception of a reality to be defined by the corresponding test. Examples of such an influence may be found in the field of materials testing. Related phenomena can be dealt with by reference to current concepts of cognitive science and psychology of the perception of images

  6. Mapping from rectangular to harmonic representation

    International Nuclear Information System (INIS)

    Schneider, W.; Bateman, G.

    1986-08-01

    An algorithm is developed to determine the Fourier harmonics representing the level contours of a scalar function given on a rectangular grid. This method is applied to the problem of computing the flux coordinates and flux surface average needed for 1-1/2-D transport codes and MHD stability codes from an equilibrium flux function given on a rectangular grid

  7. Power Divider for Waveforms Rich in Harmonics

    Science.gov (United States)

    Sims, William Herbert, III

    2005-01-01

    A method for dividing the power of an electronic signal rich in harmonics involves the use of an improved divider topology. A divider designed with this topology could be used, for example, to propagate a square-wave signal in an amplifier designed with a push-pull configuration to enable the generation of more power than could be generated in another configuration.

  8. A current controller of grid-connected converter for harmonic damping in a distribution network

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Chen, Zhe

    2011-01-01

    Harmonic resonance caused by the increased use of shunt-connected capacitors in LCL-filters and power factor correction devices may become a serious power quality challenge in electric distribution systems. A voltage-detection method based on current control is developed to damp harmonic resonances....... However, it is susceptible to the mismatch between harmonic conductance and characteristic impedance of distribution feeder. This paper proposes a current controller which allows discrete adjustment of harmonic conductance for both the characteristic harmonic and the non-characteristic harmonic voltages...

  9. Accelerated Test Method for Corrosion Protective Coatings Project

    Science.gov (United States)

    Falker, John; Zeitlin, Nancy; Calle, Luz

    2015-01-01

    This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as accurately and reliably as current long-term atmospheric exposure tests. This new accelerated test method will shorten the time needed to evaluate the corrosion protection performance of coatings for NASA's critical ground support structures. Lifetime prediction for spaceport structure coatings has a 5-year qualification cycle using atmospheric exposure. Current accelerated corrosion tests often provide false positives and negatives for coating performance, do not correlate to atmospheric corrosion exposure results, and do not correlate with atmospheric exposure timescales for lifetime prediction.

  10. Test Method for Spalling of Fire Exposed Concrete

    DEFF Research Database (Denmark)

    Hertz, Kristian Dahl; Sørensen, Lars Schiøtt

    2005-01-01

    A new material test method is presented for determining whether or not an actual concrete may suffer from explosive spalling at a specified moisture level. The method takes into account the effect of stresses from hindered thermal expansion at the fire-exposed surface. Cylinders are used, which...... in many countries serve as standard specimens for testing the compressive strength. Consequently, the method is quick, cheap and easy to use in comparison to the alternative of testing full-scale or semi full-scale structures with correct humidity, load and boundary conditions. A number of concretes have...

  11. The Validation of NAA Method Used as Test Method in Serpong NAA Laboratory

    International Nuclear Information System (INIS)

    Rina-Mulyaningsih, Th.

    2004-01-01

    The Validation Of NAA Method Used As Test Method In Serpong NAA Laboratory. NAA Method is a non standard testing method. The testing laboratory shall validate its using method to ensure and confirm that it is suitable with application. The validation of NAA methods have been done with the parameters of accuracy, precision, repeatability and selectivity. The NIST 1573a Tomato Leaves, NIES 10C Rice flour unpolished and standard elements were used in this testing program. The result of testing with NIST 1573a showed that the elements of Na, Zn, Al and Mn are met from acceptance criteria of accuracy and precision, whereas Co is rejected. The result of testing with NIES 10C showed that Na and Zn elements are met from acceptance criteria of accuracy and precision, but Mn element is rejected. The result of selectivity test showed that the value of quantity is between 0.1-2.5 μg, depend on the elements. (author)

  12. State of the art on alternative methods to animal testing from an industrial point of view: ready for regulation?

    Science.gov (United States)

    Ashton, Rachel; De Wever, Bart; Fuchs, Horst W; Gaca, Marianna; Hill, Erin; Krul, Cyrille; Poth, Albrecht; Roggen, Erwin L

    2014-01-01

    Despite changing attitudes towards animal testing and current legislation to protect experimental animals, the rate of animal experiments seems to have changed little in recent years. On May 15-16, 2013, the In Vitro Testing Industrial Platform (IVTIP) held an open meeting to discuss the state of the art in alternative methods, how companies have, can, and will need to adapt and what drives and hinders regulatory acceptance and use. Several key messages arose from the meeting. First, industry and regulatory bodies should not wait for complete suites of alternative tests to become available, but should begin working with methods available right now (e.g., mining of existing animal data to direct future studies, implementation of alternative tests wherever scientifically valid rather than continuing to rely on animal tests) in non-animal and animal integrated strategies to reduce the numbers of animals tested. Sharing of information (communication), harmonization and standardization (coordination), commitment and collaboration are all required to improve the quality and speed of validation, acceptance, and implementation of tests. Finally, we consider how alternative methods can be used in research and development before formal implementation in regulations. Here we present the conclusions on what can be done already and suggest some solutions and strategies for the future.

  13. Mechanical/structural performance test method of a spacer grid

    International Nuclear Information System (INIS)

    Yoon, Kyung Ho

    2000-06-01

    The spacer grid is one of the main structural components in the fuel assembly, which supports the fuel rods, guides cooling water, and protects the system from an external impact load, such as earthquakes. In order to develop the spacer grid with the high mechanical performance, the mechanical and structural properties of the spacer grids must be extensively examined while designing it. In this report, the mechanical/structural test methods, i.e. the characteristic test of a spacer grid spring or dimple, static buckling test of a partial or full size spacer grid and dynamic impact test of them are described. The characteristic test of a spacer grid spring or dimple is accomplished with universal tensile test machine, a specimen is fixed with test fixture and then applied compressive load. The characteristic test data is saved at loading and unloading event. The static buckling test of a partial or full size spacer grid is executed with the same universal tensile testing machine, a specimen is fixed between cross-heads and then applied the compressive load. The buckling strength is decided the maximum strength at load vs. displacement curve. The dynamic impact test of a partial or full size spacer grid is performed with pendulum type impact machine and free fall shock test machine, a specimen is fixed with test fixture and then applied the impact load by impact hammer. Specially, the pendulum type impact test machine is also possible under the operating temperature because a furnace is separately attached with test machine

  14. Comparison of high efficiency particulate filter testing methods

    International Nuclear Information System (INIS)

    1985-01-01

    High Efficiency Particulate Air (HEPA) filters are used for the removal of submicron size particulates from air streams. In nuclear industry they are used as an important engineering safeguard to prevent the release of air borne radioactive particulates to the environment. HEPA filters used in the nuclear industry should therefore be manufactured and operated under strict quality control. There are three levels of testing HEPA filters: i) testing of the filter media; ii) testing of the assembled filter including filter media and filter housing; and iii) on site testing of the complete filter installation before putting into operation and later for the purpose of periodic control. A co-ordinated research programme on particulate filter testing methods was taken up by the Agency and contracts were awarded to the Member Countries, Belgium, German Democratic Republic, India and Hungary. The investigations carried out by the participants of the present co-ordinated research programme include the results of the nowadays most frequently used HEPA filter testing methods both for filter medium test, rig test and in-situ test purposes. Most of the experiments were carried out at ambient temperature and humidity, but indications were given to extend the investigations to elevated temperature and humidity in the future for the purpose of testing the performance of HEPA filter under severe conditions. A major conclusion of the co-ordinated research programme was that it was not possible to recommend one method as a reference method for in situ testing of high efficiency particulate air filters. Most of the present conventional methods are adequate for current requirements. The reasons why no method is to be recommended were multiple, ranging from economical aspects, through incompatibility of materials to national regulations

  15. Standard Test Method for Saltwater Pressure Immersion and Temperature Testing of Photovoltaic Modules for Marine Environments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method provides a procedure for determining the ability of photovoltaic modules to withstand repeated immersion or splash exposure by seawater as might be encountered when installed in a marine environment, such as a floating aid-to-navigation. A combined environmental cycling exposure with modules repeatedly submerged in simulated saltwater at varying temperatures and under repetitive pressurization provides an accelerated basis for evaluation of aging effects of a marine environment on module materials and construction. 1.2 This test method defines photovoltaic module test specimens and requirements for positioning modules for test, references suitable methods for determining changes in electrical performance and characteristics, and specifies parameters which must be recorded and reported. 1.3 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method. 1.4 The values stated in SI units are to be ...

  16. In Silico Toxicology – Non-Testing Methods

    Science.gov (United States)

    Raunio, Hannu

    2011-01-01

    In silico toxicology in its broadest sense means “anything that we can do with a computer in toxicology.” Many different types of in silico methods have been developed to characterize and predict toxic outcomes in humans and environment. The term non-testing methods denote grouping approaches, structure–activity relationship, and expert systems. These methods are already used for regulatory purposes and it is anticipated that their role will be much more prominent in the near future. This Perspective will delineate the basic principles of non-testing methods and evaluate their role in current and future risk assessment of chemical compounds. PMID:21772821

  17. Methods and characteristics of assembly language software testing

    International Nuclear Information System (INIS)

    Wang Lingfang

    2001-01-01

    Single chip micro-controllers are widely implemented to the controlling and testing products in industrial controlling and national defence embedded controlling systems. The invalidation of the source programs could lead to the unreliability of the whole systems, even to cause fatal results. Therefore, software testing is the necessary measures to reduce the mistakes and to improve the quality of the software. In the paper, the development of the software testing is presented. The distinctions between the assembly language testing and those of the high level languages is introduced. And the essential flow and methods of software testing are discussed in detail

  18. A modular spherical harmonics approach to the neutron transport equation

    International Nuclear Information System (INIS)

    Inanc, F.; Rohach, A.F.

    1989-01-01

    A modular nodal method was developed for solving the neutron transport equation in 2-D xy coordinates. The spherical harmonic expansion was used for approximating the second-order even-parity form of the neutron transport equation. The boundary conditions of the spherical harmonics approximation were derived in a form to have forms analogous to the partial currents in the neutron diffusion equation. Relations were developed for generating both the second-order spherical harmonic equations and the boundary conditions in an automated computational algorithm. Nodes using different orders of the spherical harmonics approximation to the transport equation were interfaced through mixed-type boundary conditions. The determination of spherical harmonic orders implemented in the nodes were determined by the scheme in an automated manner. Results of the method compared favorably to benchmark problems. (author)

  19. Next generation data harmonization

    Science.gov (United States)

    Armstrong, Chandler; Brown, Ryan M.; Chaves, Jillian; Czerniejewski, Adam; Del Vecchio, Justin; Perkins, Timothy K.; Rudnicki, Ron; Tauer, Greg

    2015-05-01

    Analysts are presented with a never ending stream of data sources. Often, subsets of data sources to solve problems are easily identified but the process to align data sets is time consuming. However, many semantic technologies do allow for fast harmonization of data to overcome these problems. These include ontologies that serve as alignment targets, visual tools and natural language processing that generate semantic graphs in terms of the ontologies, and analytics that leverage these graphs. This research reviews a developed prototype that employs all these approaches to perform analysis across disparate data sources documenting violent, extremist events.

  20. Relative Merits of Four Methods for Scoring Cloze Tests.

    Science.gov (United States)

    Brown, James Dean

    1980-01-01

    Describes study comparing merits of exact answer, acceptable answer, clozentropy and multiple choice methods for scoring tests. Results show differences among reliability, mean item facility, discrimination and usability, but not validity. (BK)

  1. A True-False Test on Methods of Typewriting Instruction.

    Science.gov (United States)

    West, Leonard J.

    1984-01-01

    Presents a true-false test on typewriting instruction to illustrate the effects of educational lag, publishing practices, and deficiencies in preservice and inservice teacher education upon teaching methods. (SK)

  2. Test Methods for Effects on Organisms:Springtails

    OpenAIRE

    Krogh, P. H.

    1997-01-01

    NORD-UTTE er Nordisk koordineringsgrupp för utvekling av testmetoder inom toxicologi och ekotoxicology. The Nordic Co-ordination Group for the Development of Test Methods for Toxicology and Ecotoxicology

  3. Harmonic analysis of electrified railway based on improved HHT

    Science.gov (United States)

    Wang, Feng

    2018-04-01

    In this paper, the causes and harms of the current electric locomotive electrical system harmonics are firstly studied and analyzed. Based on the characteristics of the harmonics in the electrical system, the Hilbert-Huang transform method is introduced. Based on the in-depth analysis of the empirical mode decomposition method and the Hilbert transform method, the reasons and solutions to the endpoint effect and modal aliasing problem in the HHT method are explored. For the endpoint effect of HHT, this paper uses point-symmetric extension method to extend the collected data; In allusion to the modal aliasing problem, this paper uses the high frequency harmonic assistant method to preprocess the signal and gives the empirical formula of high frequency auxiliary harmonic. Finally, combining the suppression of HHT endpoint effect and modal aliasing problem, an improved HHT method is proposed and simulated by matlab. The simulation results show that the improved HHT is effective for the electric locomotive power supply system.

  4. From the Kirsch-Kress potential method via the range test to the singular sources method

    International Nuclear Information System (INIS)

    Potthast, R; Schulz, J

    2005-01-01

    We review three reconstruction methods for inverse obstacle scattering problems. We will analyse the relation between the Kirsch-Kress potential method 1986, the range test of Kusiak, Potthast and Sylvester (2003) and the singular sources method of Potthast (2000). In particular, we show that the range test is a logical extension of the Kirsch-Kress method into the category of sampling methods employing the tool of domain sampling. Then we will show how a multi-wave version of the range test can be set up and we will work out its relation to the singular sources method. Numerical examples and demonstrations will be provided

  5. Two micro fatigue test methods for irradiated materials

    International Nuclear Information System (INIS)

    Nunomura, Shigetomo; Noguchi, Shinji; Okamura, Yuichi; Kumai, Shinji

    1993-01-01

    This paper demonstrates two miniature fatigue test methods in response to the requirements of the fusion reactor wall materials development program. It is known that the fatigue strength evaluated by the axial loading test is independent of the specimen size, while that evaluated by the bend test or torsion test is dependent upon the size of specimen. The new type of gripping system for the axial, tension-tension, fatigue testing of TEM disk-size specimens that has been developed is described in this paper. An alignment tool assists in gripping the miniature specimen. The miniature tension-tension fatigue test method seems to provide reliable S-N curves for SUS304 and SUS316L stainless steels. An indentation method has also been developed to determine fatigue properties. A hard steel ball or ceramic ball was used for cyclically loading the specimen, and an S-N curve was subsequently obtained. The merit of this method is primarily simple handling. S-N curves obtained from four materials by this indentation method compared well with those obtained from the rotary bend fatigue test employing a standard-size specimen

  6. Review of Artificial Abrasion Test Methods for PV Module Technology

    Energy Technology Data Exchange (ETDEWEB)

    Miller, David C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Muller, Matt T. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Simpson, Lin J. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-08-01

    This review is intended to identify the method or methods--and the basic details of those methods--that might be used to develop an artificial abrasion test. Methods used in the PV literature were compared with their closest implementation in existing standards. Also, meetings of the International PV Quality Assurance Task Force Task Group 12-3 (TG12-3, which is concerned with coated glass) were used to identify established test methods. Feedback from the group, which included many of the authors from the PV literature, included insights not explored within the literature itself. The combined experience and examples from the literature are intended to provide an assessment of the present industry practices and an informed path forward. Recommendations toward artificial abrasion test methods are then identified based on the experiences in the literature and feedback from the PV community. The review here is strictly focused on abrasion. Assessment methods, including optical performance (e.g., transmittance or reflectance), surface energy, and verification of chemical composition were not examined. Methods of artificially soiling PV modules or other specimens were not examined. The weathering of artificial or naturally soiled specimens (which may ultimately include combined temperature and humidity, thermal cycling and ultraviolet light) were also not examined. A sense of the purpose or application of an abrasion test method within the PV industry should, however, be evident from the literature.

  7. Methodical approaches to solving special problems of testing. Seminar papers

    International Nuclear Information System (INIS)

    1996-01-01

    This Seminar volume introduces concepts and applications from different areas of application of ultrasonic testing and other non-destructive test methods in 18 lectures, in order to give an idea of new trends in development and stimuli for special solutions to problems. 3 articles were recorded separately for the ENERGY data bank. (orig./MM) [de

  8. Nondestructive testing methods in building industry '83. Part 1

    International Nuclear Information System (INIS)

    1983-10-01

    The conference heard 52 papers of which 11 were incorporated in INIS. The subject of these was the use of radiometric methods and instruments for nondestructive testing of building materials and ways of testing the quality of concrete during nuclear power plant construction. (J.P.)

  9. 40 CFR 63.425 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... maximum allowable 5-minute pressure increase is 130 mm H2 O (5 in. H2 O). (f) Leak detection test. The leak detection test shall be performed using Method 21, appendix A, 40 CFR part 60, except omit section... between each leak detection. The duration of the purge shall be in excess of two instrument response times...

  10. 40 CFR 63.1046 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ...) National Emission Standards for Oil-Water Separators and Organic-Water Separators § 63.1046 Test methods... vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak... test, the cover and closure devices shall be secured in the closed position. (3) The detection...

  11. Moisture distribution in sludges based on different testing methods

    Institute of Scientific and Technical Information of China (English)

    Wenyi Deng; Xiaodong Li; Jianhua Yan; Fei Wang; Yong Chi; Kefa Cen

    2011-01-01

    Moisture distributions in municipal sewage sludge, printing and dyeing sludge and paper mill sludge were experimentally studied based on four different methods, i.e., drying test, thermogravimetric-differential thermal analysis (TG-DTA) test, thermogravimetricdifferential scanning calorimetry (TG-DSC) test and water activity test. The results indicated that the moistures in the mechanically dewatered sludges were interstitial water, surface water and bound water. The interstitial water accounted for more than 50% wet basis (wb) of the total moisture content. The bond strength of sludge moisture increased with decreasing moisture content, especially when the moisture content was lower than 50% wb. Furthermore, the comparison among the four different testing methods was presented.The drying test was advantaged by its ability to quantify free water, interstitial water, surface water and bound water; while TG-DSC test, TG-DTA test and water activity test were capable of determining the bond strength of moisture in sludge. It was found that the results from TG-DSC and TG-DTA test are more persuasive than water activity test.

  12. Mirror bootstrap method for testing hypotheses of one mean

    OpenAIRE

    Varvak, Anna

    2012-01-01

    The general philosophy for bootstrap or permutation methods for testing hypotheses is to simulate the variation of the test statistic by generating the sampling distribution which assumes both that the null hypothesis is true, and that the data in the sample is somehow representative of the population. This philosophy is inapplicable for testing hypotheses for a single parameter like the population mean, since the two assumptions are contradictory (e.g., how can we assume both that the mean o...

  13. Voltage harmonic variation in three-phase induction motors with different coil pitches

    International Nuclear Information System (INIS)

    Deshmukh, Ram; Moses, Anthony John; Anayi, Fatih

    2006-01-01

    A pulse-width modulation (PWM) inverter feeding four different chorded three-phase induction motors was tested for low-order odd harmonic voltage component and efficiency at different loads. Total harmonic distortion (THD) due to 3rd, 5th and 9th harmonics was less in a motor with 160 o coil pitch. Particular harmonic order for each coil pitch was suppressed and the efficiency of a 120 o coil pitch motor was increased by 7.5%

  14. Overview of multi-input frequency domain modal testing methods with an emphasis on sine testing

    Science.gov (United States)

    Rost, Robert W.; Brown, David L.

    1988-01-01

    An overview of the current state of the art multiple-input, multiple-output modal testing technology is discussed. A very brief review of the current time domain methods is given. A detailed review of frequency and spatial domain methods is presented with an emphasis on sine testing.

  15. 40 CFR 60.1300 - What test methods must I use to stack test?

    Science.gov (United States)

    2010-07-01

    ... to the Administrator for approval under § 60.8(b) to use a reference method with minor changes in... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What test methods must I use to stack test? 60.1300 Section 60.1300 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...

  16. Test report for cesium powder and pellets inner container decontamination method determination test

    International Nuclear Information System (INIS)

    Kelly, D.L.

    1998-01-01

    This report documents the decontamination method determination testing that was performed on three cesium powder and pellets inner container test specimens The test specimens were provided by B and W Hanford Company (BVMC). The tests were conducted by the Numatec Hanford Company (NHC), in the 305 Building. Photographic evidence was also provided by NHC. The Test Plan and Test Report were provided by Waste Management Federal Services, Inc., Northwest Operations. Witnesses to testing included a test engineer, a BC project engineer, and a BC Quality Assurance (QA) representative. The Test Plan was modified with the mutual decision of the test engineer, the BWHC project engineer, and the BVMC QA representative. The results of this decision were written in red (permanent type) ink on the official copy of the test procedure, Due to the extent of the changes, a summary of the test results are provided in Section 3.0 of this Test Report. In addition, a copy of the official copy field documentation obtained during testing is included in Appendix A. The original Test Plan (HNF-2945) will be revised to indicate that extensive changes were required in the field during testing, however, the test documentation will stand as is (i.e., it will not be retyped, text shaded, etc.) due to the inclusion of the test parameters and results into this Test Report

  17. Satellite Vibration Testing: Angle optimisation method to Reduce Overtesting

    Science.gov (United States)

    Knight, Charly; Remedia, Marcello; Aglietti, Guglielmo S.; Richardson, Guy

    2018-06-01

    Spacecraft overtesting is a long running problem, and the main focus of most attempts to reduce it has been to adjust the base vibration input (i.e. notching). Instead this paper examines testing alternatives for secondary structures (equipment) coupled to the main structure (satellite) when they are tested separately. Even if the vibration source is applied along one of the orthogonal axes at the base of the coupled system (satellite plus equipment), the dynamics of the system and potentially the interface configuration mean the vibration at the interface may not occur all along one axis much less the corresponding orthogonal axis of the base excitation. This paper proposes an alternative testing methodology in which the testing of a piece of equipment occurs at an offset angle. This Angle Optimisation method may have multiple tests but each with an altered input direction allowing for the best match between all specified equipment system responses with coupled system tests. An optimisation process that compares the calculated equipment RMS values for a range of inputs with the maximum coupled system RMS values, and is used to find the optimal testing configuration for the given parameters. A case study was performed to find the best testing angles to match the acceleration responses of the centre of mass and sum of interface forces for all three axes, as well as the von Mises stress for an element by a fastening point. The angle optimisation method resulted in RMS values and PSD responses that were much closer to the coupled system when compared with traditional testing. The optimum testing configuration resulted in an overall average error significantly smaller than the traditional method. Crucially, this case study shows that the optimum test campaign could be a single equipment level test opposed to the traditional three orthogonal direction tests.

  18. An evaluation of the whole effluent toxicity test method

    International Nuclear Information System (INIS)

    Osteen, D.V.

    1999-01-01

    Whole effluent toxicity (WET) testing has become increasingly more important to the Environmental Protection Agency (EPA) and the States in the permitting of wastewater discharges from industry and municipalities. The primary purpose of the WET test is to protect aquatic life by predicting the effect of an effluent on the receiving stream. However, there are both scientific and regulatory concerns that using WET tests to regulate industrial effluents may result in either false positives and/or false negatives. In order to realistically predict the effect of an effluent on the receiving stream, the test should be as representative as possible of the conditions in the receiving stream. Studies (Rand and Petrocelli 1985) suggested several criteria for an ideal aquatic toxicity test organism, one of which is that the organism be indigenous to, or representative of, the ecosystem receiving the effluent. The other component needed in the development of a predictive test is the use of the receiving stream water or similar synthetic water as the control and dilution water in the test method. Use of an indigenous species and receiving water in the test should help reduce the variability in the method and allow the test to predict the effect of the effluent on the receiving stream. The experience with toxicity testing at the Savannah River Site (SRS) has yielded inconclusive data because of the inconsistency and unreliability of the results. The SRS contention is that the WET method in its present form does not adequately mimic actual biological/chemical conditions of the receiving streams and is neither reasonable nor accurate. This paper discusses the rationale for such a position by SRS on toxicity testing in terms of historical permitting requirements, outfall effluent test results, standard test method evaluation, scientific review of alternate test species, and concerns over the test method expressed by other organizations. This paper presents the Savannah River Site

  19. Harmonic balance approach to the periodic solutions of the (an)harmonic relativistic oscillator

    International Nuclear Information System (INIS)

    Belendez, Augusto; Pascual, Carolina

    2007-01-01

    The first-order harmonic balance method via the first Fourier coefficient is used to construct two approximate frequency-amplitude relations for the relativistic oscillator for which the nonlinearity (anharmonicity) is a relativistic effect due to the time line dilation along the world line. Making a change of variable, a new nonlinear differential equation is obtained and two procedures are used to approximately solve this differential equation. In the first the differential equation is rewritten in a form that does not contain a square-root expression, while in the second the differential equation is solved directly. The approximate frequency obtained using the second procedure is more accurate than the frequency obtained with the first due to the fact that, in the second procedure, application of the harmonic balance method produces an infinite set of harmonics, while in the first procedure only two harmonics are produced. Both approximate frequencies are valid for the complete range of oscillation amplitudes, and excellent agreement of the approximate frequencies with the exact one are demonstrated and discussed. The discrepancy between the first-order approximate frequency obtained by means of the second procedure and the exact frequency never exceeds 1.6%. We also obtained the approximate frequency by applying the second-order harmonic balance method and in this case the relative error is as low 0.31% for all the range of values of amplitude of oscillation A

  20. Bi-harmonic cantilever design for improved measurement sensitivity in tapping-mode atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Loganathan, Muthukumaran; Bristow, Douglas A., E-mail: dbristow@mst.edu [Department of Mechanical and Aerospace Engineering, Missouri University of Science and Technology, Rolla, Missouri 65401 (United States)

    2014-04-15

    This paper presents a method and cantilever design for improving the mechanical measurement sensitivity in the atomic force microscopy (AFM) tapping mode. The method uses two harmonics in the drive signal to generate a bi-harmonic tapping trajectory. Mathematical analysis demonstrates that the wide-valley bi-harmonic tapping trajectory is as much as 70% more sensitive to changes in the sample topography than the standard single-harmonic trajectory typically used. Although standard AFM cantilevers can be driven in the bi-harmonic tapping trajectory, they require large forcing at the second harmonic. A design is presented for a bi-harmonic cantilever that has a second resonant mode at twice its first resonant mode, thereby capable of generating bi-harmonic trajectories with small forcing signals. Bi-harmonic cantilevers are fabricated by milling a small cantilever on the interior of a standard cantilever probe using a focused ion beam. Bi-harmonic drive signals are derived for standard cantilevers and bi-harmonic cantilevers. Experimental results demonstrate better than 30% improvement in measurement sensitivity using the bi-harmonic cantilever. Images obtained through bi-harmonic tapping exhibit improved sharpness and surface tracking, especially at high scan speeds and low force fields.

  1. Bi-harmonic cantilever design for improved measurement sensitivity in tapping-mode atomic force microscopy.

    Science.gov (United States)

    Loganathan, Muthukumaran; Bristow, Douglas A

    2014-04-01

    This paper presents a method and cantilever design for improving the mechanical measurement sensitivity in the atomic force microscopy (AFM) tapping mode. The method uses two harmonics in the drive signal to generate a bi-harmonic tapping trajectory. Mathematical analysis demonstrates that the wide-valley bi-harmonic tapping trajectory is as much as 70% more sensitive to changes in the sample topography than the standard single-harmonic trajectory typically used. Although standard AFM cantilevers can be driven in the bi-harmonic tapping trajectory, they require large forcing at the second harmonic. A design is presented for a bi-harmonic cantilever that has a second resonant mode at twice its first resonant mode, thereby capable of generating bi-harmonic trajectories with small forcing signals. Bi-harmonic cantilevers are fabricated by milling a small cantilever on the interior of a standard cantilever probe using a focused ion beam. Bi-harmonic drive signals are derived for standard cantilevers and bi-harmonic cantilevers. Experimental results demonstrate better than 30% improvement in measurement sensitivity using the bi-harmonic cantilever. Images obtained through bi-harmonic tapping exhibit improved sharpness and surface tracking, especially at high scan speeds and low force fields.

  2. Comments on the sequential probability ratio testing methods

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A. [Hungarian Academy of Sciences, Budapest (Hungary). Central Research Inst. for Physics

    1996-07-01

    In this paper the classical sequential probability ratio testing method (SPRT) is reconsidered. Every individual boundary crossing event of the SPRT is regarded as a new piece of evidence about the problem under hypothesis testing. The Bayes method is applied for belief updating, i.e. integrating these individual decisions. The procedure is recommended to use when the user (1) would like to be informed about the tested hypothesis continuously and (2) would like to achieve his final conclusion with high confidence level. (Author).

  3. INTER LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON

    Science.gov (United States)

    2018-03-26

    data by Instrumentation for Impact  Test , SAE standard J211‐1 [4]. Although the entire curve is collected, the interest of this  project  team  solely...HELMET BLUNT IMPACT TEST METHOD COMPARISON by Tony J. Kayhart Charles A. Hewitt and Jonathan Cyganik March 2018 Final...INTER-LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR

  4. 40 CFR 63.750 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... method in production on actual production parts or assemblies for a period of time sufficient to coat an... a laboratory or pilot production area, using parts and coatings representative of the process(es) where the alternative method is to be used. The laboratory test will use the same part configuration(s...

  5. Solubility tests and the peripheral blood film method for screening ...

    African Journals Online (AJOL)

    Objective. To determine the cost benefit of screening for sicklecell disease among infants at district health centres in Uganda using sickling, solubility tests and the peripheral blood film method. Methods. Pilot screening services were established at district health centres. Cost benefit analysis (CBA) was performed in four ...

  6. 40 CFR 60.46 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... material balance over the steam generating system shall be used to confirm the rate. (d) The owner or...-Fired Steam Generators for Which Construction Is Commenced After August 17, 1971 § 60.46 Test methods... D2015, or D5865 (solid fuels), D240 (liquid fuels), or D1826 (gaseous fuels) (all of these methods are...

  7. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  8. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  9. Pairwise harmonics for shape analysis

    KAUST Repository

    Zheng, Youyi

    2013-07-01

    This paper introduces a simple yet effective shape analysis mechanism for geometry processing. Unlike traditional shape analysis techniques which compute descriptors per surface point up to certain neighborhoods, we introduce a shape analysis framework in which the descriptors are based on pairs of surface points. Such a pairwise analysis approach leads to a new class of shape descriptors that are more global, discriminative, and can effectively capture the variations in the underlying geometry. Specifically, we introduce new shape descriptors based on the isocurves of harmonic functions whose global maximum and minimum occur at the point pair. We show that these shape descriptors can infer shape structures and consistently lead to simpler and more efficient algorithms than the state-of-the-art methods for three applications: intrinsic reflectional symmetry axis computation, matching shape extremities, and simultaneous surface segmentation and skeletonization. © 2012 IEEE.

  10. Comparative study of in-situ filter test methods

    International Nuclear Information System (INIS)

    Marshall, M.; Stevens, D.C.

    1981-01-01

    Available methods of testing high efficiency particulate aerosol (HEPA) filters in-situ have been reviewed. In order to understand the relationship between the results produced by different methods a selection has been compared. Various pieces of equipment for generating and detecting aerosols have been tested and their suitability assessed. Condensation-nuclei, DOP (di-octyl phthalate) and sodium-flame in-situ filter test methods have been studied, using the 500 cfm (9000 m 3 /h) filter test rig at Harwell and in the field. Both the sodium-flame and DOP methods measure the penetration through leaks and filter material. However the measured penetration through filtered leaks depends on the aerosol size distribution and the detection method. Condensation-nuclei test methods can only be used to measure unfiltered leaks since condensation nuclei have a very low penetration through filtered leaks. A combination of methods would enable filtered and unfiltered leaks to be measured. A condensation-nucleus counter using n-butyl alcohol as the working fluid has the advantage of being able to detect any particle up to 1 μm in diameter, including DOP, and so could be used for this purpose. A single-particle counter has not been satisfactory because of interference from particles leaking into systems under extract, particularly downstream of filters, and because the concentration of the input aerosol has to be severely limited. The sodium-flame method requires a skilled operator and may cause safety and corrosion problems. The DOP method using a total light scattering detector has so far been the most satisfactory. It is fairly easy to use, measures reasonably low values of penetration and gives rapid results. DOP has had no adverse effect on HEPA filters over a long series of tests

  11. High-frequency harmonic imaging of the eye

    Science.gov (United States)

    Silverman, Ronald H.; Coleman, D. Jackson; Ketterling, Jeffrey A.; Lizzi, Frederic L.

    2005-04-01

    Purpose: Harmonic imaging has become a well-established technique for ultrasonic imaging at fundamental frequencies of 10 MHz or less. Ophthalmology has benefited from the use of fundamentals of 20 MHz to 50 MHz. Our aim was to explore the ability to generate harmonics for this frequency range, and to generate harmonic images of the eye. Methods: The presence of harmonics was determined in both water and bovine vitreous propagation media by pulse/echo and hydrophone at a series of increasing excitation pulse intensities and frequencies. Hydrophone measurements were made at the focal point and in the near- and far-fields of 20 MHz and 40 MHz transducers. Harmonic images of the anterior segment of the rabbit eye were obtained by a combination of analog filtering and digital post-processing. Results: Harmonics were generated nearly identically in both water and vitreous. Hydrophone measurements showed the maximum second harmonic to be -5 dB relative to the 35 MHz fundamental at the focus, while in pulse/echo the maximum harmonic amplitude was -15dB relative to the fundamental. Harmonics were absent in the near-field, but present in the far-field. Harmonic images of the eye showed improved resolution. Conclusion: Harmonics can be readily generated at very high frequencies, and at power levels compliant with FDA guidelines for ophthalmology. This technique may yield further improvements to the already impressive resolutions obtainable in this frequency range. Improved imaging of the macular region, in particular, may provide significant improvements in diagnosis of retinal disease.

  12. Standard Test Method for Contamination Outgassing Characteristics of Spacecraft Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers a technique for generating data to characterize the kinetics of the release of outgassing products from materials. This technique will determine both the total mass flux evolved by a material when exposed to a vacuum environment and the deposition of this flux on surfaces held at various specified temperatures. 1.2 This test method describes the test apparatus and related operating procedures for evaluating the total mass flux that is evolved from a material being subjected to temperatures that are between 298 and 398 K. Pressures external to the sample effusion cell are less than 7 × 10−3 Pa (5 × 10−5 torr). Deposition rates are measured during material outgassing tests. A test procedure for collecting data and a test method for processing and presenting the collected data are included. 1.3 This test method can be used to produce the data necessary to support mathematical models used for the prediction of molecular contaminant generation, migration, and deposition. 1.4 Al...

  13. Test of a method for phase retrieval in HRTEM

    International Nuclear Information System (INIS)

    Beeching, M.J.; Spargo, A.E.C.

    1992-01-01

    Several methods of phase retrieval from the high resolution transmission electron microscopy image intensity distributions have been proposed but no standard method has emerged. The results achieved using a technique based on a development of the focus variation method, are reported. The dependence of the retrieved wavefunction on various experimental parameters is investigated and the method tested using computer simulated images. The method is shown to be useful in finding the complex wavefield at the exit surface of the specimen but the relationship of this to the specimen structure is considered as a separate issue. 1 ref., 3 figs

  14. Testing methods of steel wi re ropes at the anchor

    Directory of Open Access Journals (Sweden)

    Stanislav Kropuch

    2012-12-01

    Full Text Available The present paper introduces an application of the acoustic andthermographic method in the defectoscopic testing of immobilesteel wire ropes at the most critical point, the anchor. Firstmeasurements and their results by these new defectoscopic methodsare shown. In defectoscopic tests at the anchor, the widelyused magnetic method gives unreliable results, and therefore presentsa problem for steel wire defectoscopy. Application of the two new methods in the steel wire defectoscopy at the anchor point will enableincreased safety measures at the anchor of steel wire ropes in bridge, roof, tower and aerial cable lift constructions.

  15. Testing and Validation of the Dynamic Inertia Measurement Method

    Science.gov (United States)

    Chin, Alexander W.; Herrera, Claudia Y.; Spivey, Natalie D.; Fladung, William A.; Cloutier, David

    2015-01-01

    The Dynamic Inertia Measurement (DIM) method uses a ground vibration test setup to determine the mass properties of an object using information from frequency response functions. Most conventional mass properties testing involves using spin tables or pendulum-based swing tests, which for large aerospace vehicles becomes increasingly difficult and time-consuming, and therefore expensive, to perform. The DIM method has been validated on small test articles but has not been successfully proven on large aerospace vehicles. In response, the National Aeronautics and Space Administration Armstrong Flight Research Center (Edwards, California) conducted mass properties testing on an "iron bird" test article that is comparable in mass and scale to a fighter-type aircraft. The simple two-I-beam design of the "iron bird" was selected to ensure accurate analytical mass properties. Traditional swing testing was also performed to compare the level of effort, amount of resources, and quality of data with the DIM method. The DIM test showed favorable results for the center of gravity and moments of inertia; however, the products of inertia showed disagreement with analytical predictions.

  16. NNWSI waste form test method for unsaturated disposal conditions

    International Nuclear Information System (INIS)

    Bates, J.K.; Gerding, T.J.

    1985-03-01

    A test method has been developed to measure the release of radionuclides from the waste package under simulated NNWSI repository conditions, and to provide information concerning materials interactions that may occur in the repository. Data are presented from Unsaturated testing of simulated Savannah River Laboratory 165 glass completed through 26 weeks. The relationship between these results and those from parametric and analog testing are described. The data indicate that the waste form test is capable of producing consistent, reproducible results that will be useful in evaluating the role of the waste package in the long-term performance of the repository. 6 refs., 7 figs., 5 tabs

  17. Valid methods: the quality assurance of test method development, validation, approval, and transfer for veterinary testing laboratories.

    Science.gov (United States)

    Wiegers, Ann L

    2003-07-01

    Third-party accreditation is a valuable tool to demonstrate a laboratory's competence to conduct testing. Accreditation, internationally and in the United States, has been discussed previously. However, accreditation is only I part of establishing data credibility. A validated test method is the first component of a valid measurement system. Validation is defined as confirmation by examination and the provision of objective evidence that the particular requirements for a specific intended use are fulfilled. The international and national standard ISO/IEC 17025 recognizes the importance of validated methods and requires that laboratory-developed methods or methods adopted by the laboratory be appropriate for the intended use. Validated methods are therefore required and their use agreed to by the client (i.e., end users of the test results such as veterinarians, animal health programs, and owners). ISO/IEC 17025 also requires that the introduction of methods developed by the laboratory for its own use be a planned activity conducted by qualified personnel with adequate resources. This article discusses considerations and recommendations for the conduct of veterinary diagnostic test method development, validation, evaluation, approval, and transfer to the user laboratory in the ISO/IEC 17025 environment. These recommendations are based on those of nationally and internationally accepted standards and guidelines, as well as those of reputable and experienced technical bodies. They are also based on the author's experience in the evaluation of method development and transfer projects, validation data, and the implementation of quality management systems in the area of method development.

  18. Alternative methods for toxicity assessments in fish: comparison of the fish embryo toxicity and the larval growth and survival tests in zebrafish and fathead minnows.

    Science.gov (United States)

    Jeffries, Marlo K Sellin; Stultz, Amy E; Smith, Austin W; Rawlings, Jane M; Belanger, Scott E; Oris, James T

    2014-11-01

    An increased demand for chemical toxicity evaluations has resulted in the need for alternative testing strategies that address animal welfare concerns. The fish embryo toxicity (FET) test developed for zebrafish (Danio rerio) is one such alternative, and the application of the FET test to other species such as the fathead minnow (Pimephales promelas) has been proposed. In the present study, the performances of the FET test and the larval growth and survival (LGS; a standard toxicity testing method) test in zebrafish and fathead minnows were evaluated. This required that testing methods for the fathead minnow FET and zebrafish LGS tests be harmonized with existing test methods and that the performance of these testing strategies be evaluated by comparing the median lethal concentrations of 2 reference toxicants, 3,4-dicholoraniline and ammonia, obtained via each of the test types. The results showed that procedures for the zebrafish FET test can be adapted and applied to the fathead minnow. Differences in test sensitivity were observed for 3,4-dicholoraniline but not ammonia; therefore, conclusions regarding which test types offer the least or most sensitivity could not be made. Overall, these results show that the fathead minnow FET test has potential as an alternative toxicity testing strategy and that further analysis with other toxicants is warranted in an effort to better characterize the sensitivity and feasibility of this testing strategy. © 2014 SETAC.

  19. Testing and Validation of Computational Methods for Mass Spectrometry.

    Science.gov (United States)

    Gatto, Laurent; Hansen, Kasper D; Hoopmann, Michael R; Hermjakob, Henning; Kohlbacher, Oliver; Beyer, Andreas

    2016-03-04

    High-throughput methods based on mass spectrometry (proteomics, metabolomics, lipidomics, etc.) produce a wealth of data that cannot be analyzed without computational methods. The impact of the choice of method on the overall result of a biological study is often underappreciated, but different methods can result in very different biological findings. It is thus essential to evaluate and compare the correctness and relative performance of computational methods. The volume of the data as well as the complexity of the algorithms render unbiased comparisons challenging. This paper discusses some problems and challenges in testing and validation of computational methods. We discuss the different types of data (simulated and experimental validation data) as well as different metrics to compare methods. We also introduce a new public repository for mass spectrometric reference data sets ( http://compms.org/RefData ) that contains a collection of publicly available data sets for performance evaluation for a wide range of different methods.

  20. Interesting Developments in Testing Methods Applied to Foundation Piles

    Science.gov (United States)

    Sobala, Dariusz; Tkaczyński, Grzegorz

    2017-10-01

    Both: piling technologies and pile testing methods are a subject of current development. New technologies, providing larger diameters or using in-situ materials, are very demanding in terms of providing proper quality of execution of works. That concerns the material quality and continuity which define the integral strength of pile. On the other side we have the capacity of the ground around the pile and its ability to carry the loads transferred by shaft and pile base. Inhomogeneous nature of soils and a relatively small amount of tested piles imposes very good understanding of small amount of results. In some special cases the capacity test itself form an important cost in the piling contract. This work presents a brief description of selected testing methods and authors remarks based on cooperation with Universities constantly developing new ideas. Paper presents some experience based remarks on integrity testing by means of low energy impact (low strain) and introduces selected (Polish) developments in the field of closed-end pipe piles testing based on bi-directional loading, similar to Osterberg idea, but without sacrificial hydraulic jack. Such test is suitable especially when steel piles are used for temporary support in the rivers, where constructing of conventional testing appliance with anchor piles or kentledge meets technical problems. According to the author’s experience, such tests were not yet used on the building site but they bring a real potential especially, when the displacement control can be provided from the river bank using surveying techniques.

  1. Verification methods for treaties limiting and banning nuclear tests

    International Nuclear Information System (INIS)

    Voloshin, N.P.

    1998-01-01

    Treaty on limitation of underground nuclear weapon tests and treaty on world banning of nuclear tests contribute to and accompany the process of nuclear disarmament. Test ban in three (Moscow treaty of 1963) as well as the Threshold Test Ban up to 1991 was controlled only with national means. But since 1991 nuclear test threshold of 150 kt has been measured with hydrodynamic and tele seismic methods and checked by the inspection. Distinctive feature of this control is that control is that it is bilateral. This conforms to Treaty on limitation of underground nuclear weapon tests signed by two countries - USA and USSR. The inspection at the place of tests requires monitoring of the test site of the party conducting a test and geological information of rock in the area of explosion. In the treaty of the World Nuclear Test Ban the following ways of international control are provided for: - seismologic measurements; - radionuclide measurements; - hydro-acoustics measurements; - infra-sound measurements; - inspection at the place of the tests conduction

  2. Benefits from the BESSY FEL Higher Harmonic Radiation

    CERN Document Server

    Goldammer, K

    2005-01-01

    In the FEL process, bunching and coherent radiation is produced at the fundamental frequency as well as its higher harmonics. BESSY proposes a linac-based cascaded High-Gain Harmonic-Generation (HGHG) free electron laser (FEL) multi-user facility. The BESSY soft X-ray FEL will be seeded by three lasers spanning the spectral range of 230nm to 460nm. Two to four HGHG stages downconvert the seed wavelength to the desired radiation range of 1.24nm to 51nm using higher harmonic bunching. As a surplus, higher harmonic radiation is intrinsically produced in each FEL stage. Radiation on a higher harmonic of the FEL frequency is of high interest because it yields the possibility to reduce the number of FEL stages. This paper details extensive studies of the higher harmonic content of the BESSY FEL radiation. Important aspects of FEL interaction on higher harmonics as resulting from theory and from numerical simulations are discussed. For the case of the BESSY FEL, methods for improving the harmonic content are present...

  3. Probabilistic aspects of harmonic emission of large offshore wind farms

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Christian F. [Energinet.dk, Fredericia (Denmark); Bak, Claus L. [Aalborg Univ. (Denmark). Dept. of Energy Technology; Kocewiak, Lukasz; Hjerrild, Jesper [DONG Energy, Skaerbaek (Denmark); Berthelsen, Kasper K. [Aalborg Univ. (Denmark). Dept. of Mathematical Sciences

    2011-07-01

    In this article, a new probabilistic method of assessment of harmonic emission of large offshore wind farms is presented. Based on measurements from the British wind farm Burbo Banks, probability density functions are estimated for the dominating low order harmonic currents injected by a single turbine. The degree and type of dependence between the harmonic emission and the operating point of a single turbine is established. A model of Burbo Banks, suitable for harmonic load flow studies, is created in DIgSILENT Power Factory along with a DPL-script that deals with the probabilistic issues of the harmonic emission. The simulated harmonic distortion at the PCC is compared to measurement. This reveals some difficulties regarding harmonic load flow studies. The harmonic background distortion in the grid to where the wind farms is connected must be included in the study. Furthermore, a very detailed representation of the frequency dependent short circuit impedance must be used before sufficiently accurate results can be obtained from the model. (orig.)

  4. Comparative study of durability test methods for pellets and briquettes

    Energy Technology Data Exchange (ETDEWEB)

    Temmerman, Michaeel; Rabier, Fabienne [Centre wallon de Recherches agronomiques (CRA-W), 146, chaussee de Namur, B-5030, Gembloux (Belgium); Jensen, Peter Daugbjerg [Forest and Landscape, The Royal Veterinary and Agricultural University, Rolighedsvej 23, DK-1958 Frederiksberg C (Denmark); Hartmann, Hans; Boehm, Thorsten [Technologie- und Foerderzentrum fuer Nachwachsende Rohstoffe-TFZ, Schulgasse 18, D-94315 Straubing (Germany)

    2006-11-15

    Different methods for the determination of the mechanical durability (DU) of pellets and briquettes were compared by international round robin tests including different laboratories. The DUs of five briquette and 26 pellet types were determined. For briquettes, different rotation numbers of a prototype tumbler and a calculated DU index are compared. For pellets testing, the study compares two standard methods, a tumbling device according to ASAE S 269.4, the Lignotester according to ONORM M 7135 and a second tumbling method with a prototype tumbler. For the tested methods, the repeatability, the reproducibility and the required minimum number of replications to achieve given accuracy levels were calculated. Additionally, this study evaluates the relation between DU and particle density. The results show for both pellets and briquettes, that the measured DU values and their variability are influenced by the applied method. Moreover, the variability of the results depend on the biofuel itself. For briquettes of DU above 90%, five replications lead to an accuracy of 2%, while 39 replications are needed to achieve an accuracy of 10%, when briquettes of DU below 90% are tested. For pellets, the tumbling device described by the ASAE standard allows to reach acceptable accuracy levels (1%) with a limited number of replications. Finally, for the tested pellets and briquettes no relation between DU and particle density was found. (author)

  5. Applicability and interpretation of fracture test methods for metals

    International Nuclear Information System (INIS)

    Langford, W.J.

    1978-05-01

    Fracture tests are conducted usually out of a conviction (sometimes only vaguely defined) that they will guarantee a certain level of protecton from metal failure. Qualitative tests, such as the Charpy V-notch, produce results which cannot be rigorously related to a measure of fracture tolerance: rather, they indicate metal quality so that fracture tolerance may be inferred. Quantitative tests on the other hand provide parameters which may be used directly in equations to determine the likelihood of fracture. Both types of tests have limitations which should be understood: the paper tries to provide guidance on the relative merits of either approach for a particular purpose, and gives an insight into near-future test methods which will extend the range of usefullness of quantitative tests. (author)

  6. Antifungal susceptibility testing method for resource constrained laboratories

    Directory of Open Access Journals (Sweden)

    Khan S

    2006-01-01

    Full Text Available Purpose: In resource-constrained laboratories of developing countries determination of antifungal susceptibility testing by NCCLS/CLSI method is not always feasible. We describe herein a simple yet comparable method for antifungal susceptibility testing. Methods: Reference MICs of 72 fungal isolates including two quality control strains were determined by NCCLS/CLSI methods against fluconazole, itraconazole, voriconazole, amphotericin B and cancidas. Dermatophytes were also tested against terbinafine. Subsequently, on selection of optimum conditions, MIC was determined for all the fungal isolates by semisolid antifungal agar susceptibility method in Brain heart infusion broth supplemented with 0.5% agar (BHIA without oil overlay and results were compared with those obtained by reference NCCLS/CLSI methods. Results: Comparable results were obtained by NCCLS/CLSI and semisolid agar susceptibility (SAAS methods against quality control strains. MICs for 72 isolates did not differ by more than one dilution for all drugs by SAAS. Conclusions: SAAS using BHIA without oil overlay provides a simple and reproducible method for obtaining MICs against yeast, filamentous fungi and dermatophytes in resource-constrained laboratories.

  7. Standard Test Methods for Determining Mechanical Integrity of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover procedures for determining the ability of photovoltaic modules to withstand the mechanical loads, stresses and deflections used to simulate, on an accelerated basis, high wind conditions, heavy snow and ice accumulation, and non-planar installation effects. 1.1.1 A static load test to 2400 Pa is used to simulate wind loads on both module surfaces 1.1.2 A static load test to 5400 Pa is used to simulate heavy snow and ice accumulation on the module front surface. 1.1.3 A twist test is used to simulate the non-planar mounting of a photovoltaic module by subjecting it to a twist angle of 1.2°. 1.1.4 A cyclic load test of 10 000 cycles duration and peak loading to 1440 Pa is used to simulate dynamic wind or other flexural loading. Such loading might occur during shipment or after installation at a particular location. 1.2 These test methods define photovoltaic test specimens and mounting methods, and specify parameters that must be recorded and reported. 1.3 Any individual mech...

  8. Test cases for interface tracking methods: methodology and current status

    International Nuclear Information System (INIS)

    Lebaigue, O.; Jamet, D.; Lemonnier, E.

    2004-01-01

    Full text of publication follows:In the past decade, a large number of new methods have been developed to deal with interfaces in the numerical simulation of two-phase flows. We have collected a set of 36 test cases, which can be seen as a tool to help engineers and researchers selecting the most appropriate method(s) for their specific fields of application. This set can be use: - To perform an initial evaluation of the capabilities of available methods with regard to the specificity of the final application and the most important features to be recovered from the simulation. - To measure the maximum mesh size to be used for a given physical problem in order to obtain an accurate enough solution. - To assess and quantify the performances of a selected method equipped with its set of physical models. The computation of a well-documented test case allows estimating the error due to the numerical technique by comparison with reference solutions. This process is compulsory to gain confidence and credibility on the prediction capabilities of a numerical method and its physical models. - To broaden the capabilities of a given numerical technique. The test cases may be used to identify the need for improvement of the overall numerical scheme or to determine the physical part of the model, which is responsible for the observed limitations. Each test case falls within one of the following categories: - Analytical solutions of well-known sets of equations corresponding to simple geometrical situations. - Reference numerical solutions of moderately complex problems, produced by accurate methods (e.g., boundary Fitted coordinate method) on refined meshes. - Separate effects analytical experiments. The presentation will suggest how to use the test cases for assessing the physical models and the numerical methods. The expected fallout of using test cases is indeed on the one hand to identify the merits of existing methods and on the other hand to orient further research towards

  9. Standard Test Methods for Constituent Content of Composite Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods determine the constituent content of composite materials by one of two approaches. Method I physically removes the matrix by digestion or ignition by one of seven procedures, leaving the reinforcement essentially unaffected and thus allowing calculation of reinforcement or matrix content (by weight or volume) as well as percent void volume. Method II, applicable only to laminate materials of known fiber areal weight, calculates reinforcement or matrix content (by weight or volume), and the cured ply thickness, based on the measured thickness of the laminate. Method II is not applicable to the measurement of void volume. 1.1.1 These test methods are primarily intended for two-part composite material systems. However, special provisions can be made to extend these test methods to filled material systems with more than two constituents, though not all test results can be determined in every case. 1.1.2 The procedures contained within have been designed to be particularly effective for ce...

  10. A novel test tube method of screening for hemoglobin E.

    Science.gov (United States)

    Tatu, T; Kasinrerk, W

    2012-02-01

    Hemoglobin (Hb) E is a β-structural variant common worldwide. This Hb disorder can form a compound heterozygous state with the β-thalassemia gene, leading to life-threatening hereditary hemolytic anemia, HbE/β-thalassemia. Screening of HbE has proven to be a challenging practice in prevention and control of the HbE/β-thalassemia. A novel test tube method for HbE screening using diethyl aminoethyl (DEAE)-cellulose resin was described. With the developed system, HbE/A(2) did not bind to the resin and remained dissolved in the supernatant, whereas other Hbs completely bound to the resin. The red color of the supernatant observed in the test tube indicated the presence of HbE. Colorless or markedly pale color of the supernatant indicates the absence of HbE. Accuracy and efficiency of the established method in detecting HbE was comparable with the standard cellulose acetate electrophoresis method. The developed method is cheap and simple with no requirement of sophisticated equipment. The reagent could be stored at 4 °C for up to 5 months. Hemolysate samples aged up to 5 months were still suitable for this test. The described novel test tube method could be an alternative method of mass population screening for HbE, particularly in small health care facilities. © 2011 Blackwell Publishing Ltd.

  11. Second harmonic generation microscopy

    DEFF Research Database (Denmark)

    Brüggemann, Dagmar Adeline; Brewer, Jonathan R.; Risbo, Jens

    2010-01-01

    Myofibers and collagen show non-linear optical properties enabling imaging using second harmonic generation (SHG) microscopy. The technique is evaluated for use as a tool for real-time studies of thermally induced changes in thin samples of unfixed and unstained pork. The forward and the backward...... scattered SHG light reveal complementary features of the structures of myofibers and collagen fibers. Upon heating the myofibers show no structural changes before reaching a temperature of 53 °C. At this temperature the SHG signal becomes extinct. The extinction of the SHG at 53 °C coincides with a low......-temperature endotherm peak observable in the differential scanning calorimetry (DSC) thermograms. DSC analysis of epimysium, the connective tissue layer that enfold skeletal muscles, produces one large endotherm starting at 57 °C and peaking at 59.5 °C. SHG microscopy of collagen fibers reveals a variability of thermal...

  12. Azimuthal anisotropy: The higher harmonics

    International Nuclear Information System (INIS)

    Poskanzer, Arthur M.; STAR Collaboration

    2004-01-01

    We report the first observations of the fourth harmonic (v 4 ) in the azimuthal distribution of particles at RHIC. The measurement was done taking advantage of the large elliptic flow generated at RHIC. The integrated v 4 is about a factor of 10 smaller than v 2 . For the sixth (v 6 ) and eighth (v 8 ) harmonics upper limits on the magnitudes are reported

  13. Harmonic Series Meets Fibonacci Sequence

    Science.gov (United States)

    Chen, Hongwei; Kennedy, Chris

    2012-01-01

    The terms of a conditionally convergent series may be rearranged to converge to any prescribed real value. What if the harmonic series is grouped into Fibonacci length blocks? Or the harmonic series is arranged in alternating Fibonacci length blocks? Or rearranged and alternated into separate blocks of even and odd terms of Fibonacci length?

  14. Tuvan Throat Singing and Harmonics

    Science.gov (United States)

    Ruiz, Michael J.; Wilken, David

    2018-01-01

    Tuvan throat singing, also called overtone singing, provides for an exotic demonstration of the physics of harmonics as well as introducing an Asian musical aesthetic. A low fundamental is sung and the singer skillfully alters the resonances of the vocal system to enhance an overtone (harmonic above the fundamental). The result is that the…

  15. Automatic computation and solution of generalized harmonic balance equations

    Science.gov (United States)

    Peyton Jones, J. C.; Yaser, K. S. A.; Stevenson, J.

    2018-02-01

    Generalized methods are presented for generating and solving the harmonic balance equations for a broad class of nonlinear differential or difference equations and for a general set of harmonics chosen by the user. In particular, a new algorithm for automatically generating the Jacobian of the balance equations enables efficient solution of these equations using continuation methods. Efficient numeric validation techniques are also presented, and the combined algorithm is applied to the analysis of dc, fundamental, second and third harmonic response of a nonlinear automotive damper.

  16. Canonical harmonic tracking of charged particles in circular accelerators

    International Nuclear Information System (INIS)

    Kvardakov, V.; Levichev, E.

    2006-01-01

    Harmonic tracking is a method used to study non-linear particle dynamics in a circular accelerator. The tracking algorithm is based on numerical solution of the Hamilton equations of motion. An essential feature of the method is the approximation of Hamiltonian perturbation terms by a finite number of azimuthal harmonics, which provides an effective tool for optimization of non-linear particle motion. The equations of motion are solved canonically, with the first-order prediction made using the explicit Lie transformation. The major features of harmonic tracking are presented and examples of its application are discussed

  17. Canonical harmonic tracking of charged particles in circular accelerators

    Science.gov (United States)

    Kvardakov, V.; Levichev, E.

    2006-03-01

    Harmonic tracking is a method used to study non-linear particle dynamics in a circular accelerator. The tracking algorithm is based on numerical solution of the Hamilton equations of motion. An essential feature of the method is the approximation of Hamiltonian perturbation terms by a finite number of azimuthal harmonics, which provides an effective tool for optimization of non-linear particle motion. The equations of motion are solved canonically, with the first-order prediction made using the explicit Lie transformation. The major features of harmonic tracking are presented and examples of its application are discussed.

  18. [Testing methods for seed quality of Bletilla striata].

    Science.gov (United States)

    Zhang, Zhi-Hui; Liu, Da-Hui; Zhu, Xin-Yan; Ji, Peng-Zhang; Wang, Li; Shi, Ya-Na; Ma, Cong-Ji

    2016-06-01

    In order to provide a basis for establishing seed testing rules and seed quality standard of Bletilla striata, the seed quality of B.striata from different producing area was measured referring to the Rules for Agricultural Seed Testing(GB/T 3543-1995).The results showed that the seeds of B.striata passed through 20-mesh sieve for purity analysis.The weight of seeds was measured by 1000-seed method and the water content was measured at the higher temperature (133±2) ℃ for 3 hours.The seeds were cultured on the wet filter paper at 30 ℃ for 4-20 days in light for germination testing.The method of testing seed viability was that seeds were dipped into 1% TTC solution for 7 hours at temperature of 40 ℃. Copyright© by the Chinese Pharmaceutical Association.

  19. Critical wall shear stress for the EHEDG test method

    DEFF Research Database (Denmark)

    Jensen, Bo Boye Busk; Friis, Alan

    2004-01-01

    In order to simulate the results of practical cleaning tests on closed processing equipment, based on wall shear stress predicted by computational fluid dynamics, a critical wall shear stress is required for that particular cleaning method. This work presents investigations that provide a critical...... wall shear stress of 3 Pa for the standardised EHEDG cleaning test method. The cleaning tests were performed on a test disc placed in a radial flowcell assay. Turbulent flow conditions were generated and the corresponding wall shear stresses were predicted from CFD simulations. Combining wall shear...... stress predictions from a simulation using the low Re k-epsilon and one using the two-layer model of Norris and Reynolds were found to produce reliable predictions compared to empirical solutions for the ideal flow case. The comparison of wall shear stress curves predicted for the real RFC...

  20. Harmonics in transmission power systems

    DEFF Research Database (Denmark)

    Wiechowski, Wojciech Tomasz

    . The comparison shows that results obtained used both types of the cores are the same, so it is concluded that both cores can be used for harmonic measurements. Low-inductance resistors are introduced in the secondary circuits, in series with the metering and protective relaying. On those resistors, the harmonic......Some time ago, Energinet.dk, the Transmission System Operator of the 150 kV and 400 kV transmission network in Denmark, had experienced operational malfunctions of some of the measuring and protection equipment. Also an overloading of a harmonic filter has been reported, and therefore, a need...... end only so the ground is not used as a return path. A way to reduce the capacitive coupling is to provide shielding. Harmonic currents are measured using the conventional inductive voltage transformers. Both protective and metering cores were compared if they could be used for harmonic measurements...

  1. Tuvan throat singing and harmonics

    Science.gov (United States)

    Ruiz, Michael J.; Wilken, David

    2018-05-01

    Tuvan throat singing, also called overtone singing, provides for an exotic demonstration of the physics of harmonics as well as introducing an Asian musical aesthetic. A low fundamental is sung and the singer skillfully alters the resonances of the vocal system to enhance an overtone (harmonic above the fundamental). The result is that the listener hears two pitches simultaneously. Harmonics such as H8, H9, H10, and H12 form part of a pentatonic scale and are commonly selected for melody tones by Tuvan singers. A real-time spectrogram is provided in a video (Ruiz M J 2018 Video: Tuvan Throat Singing and Harmonics http://mjtruiz.com/ped/tuva/) so that Tuvan harmonics can be visualized as they are heard.

  2. Alternative containment integrity test methods, an overview of possible techniques

    International Nuclear Information System (INIS)

    Spletzer, B.L.

    1986-01-01

    A study is being conducted to develop and analyze alternative methods for testing of containment integrity. The study is focused on techniques for continuously monitoring containment integrity to provide rapid detection of existing leaks, thus providing greater certainty of the integrity of the containment at any time. The study is also intended to develop techniques applicable to the currently required Type A integrated leakage rate tests. A brief discussion of the range of alternative methods currently being considered is presented. The methods include applicability to all major containment types, operating and shutdown plant conditions, and quantitative and qualitative leakage measurements. The techniques are analyzed in accordance with the current state of knowledge of each method. The bulk of the techniques discussed are in the conceptual stage, have not been tested in actual plant conditions, and are presented here as a possible future direction for evaluating containment integrity. Of the methods considered, no single method provides optimum performance for all containment types. Several methods are limited in the types of containment for which they are applicable. The results of the study to date indicate that techniques for continuous monitoring of containment integrity exist for many plants and may be implemented at modest cost

  3. Advantages and limitations of common testing methods for antioxidants.

    Science.gov (United States)

    Amorati, R; Valgimigli, L

    2015-05-01

    Owing to the importance of antioxidants in the protection of both natural and man-made materials, a large variety of testing methods have been proposed and applied. These include methods based on inhibited autoxidation studies, which are better followed by monitoring the kinetics of oxygen consumption or of the formation of hydroperoxides, the primary oxidation products. Analytical determination of secondary oxidation products (e.g. carbonyl compounds) has also been used. The majority of testing methods, however, do not involve substrate autoxidation. They are based on the competitive bleaching of a probe (e.g. ORAC assay, β-carotene, crocin bleaching assays, and luminol assay), on reaction with a different probe (e.g. spin-trapping and TOSC assay), or they are indirect methods based on the reduction of persistent radicals (e.g. galvinoxyl, DPPH and TEAC assays), or of inorganic oxidizing species (e.g. FRAP, CUPRAC and Folin-Ciocalteu assays). Yet other methods are specific for preventive antioxidants. The relevance, advantages, and limitations of these methods are critically discussed, with respect to their chemistry and the mechanisms of antioxidant activity. A variety of cell-based assays have also been proposed, to investigate the biological activity of antioxidants. Their importance and critical aspects are discussed, along with arguments for the selection of the appropriate testing methods according to the different needs.

  4. Two-harmonic complex spectral-domain optical coherence tomography using achromatic sinusoidal phase modulation

    Science.gov (United States)

    Lu, Sheng-Hua; Huang, Siang-Ru; Chou, Che-Chung

    2018-03-01

    We resolve the complex conjugate ambiguity in spectral-domain optical coherence tomography (SD-OCT) by using achromatic two-harmonic method. Unlike previous researches, the optical phase of the fiber interferometer is modulated by an achromatic phase shifter based on an optical delay line. The achromatic phase modulation leads to a wavelength-independent scaling coefficient for the two harmonics. Dividing the mean absolute value of the first harmonic by that of the second harmonic in a B-scan interferogram directly gives the scaling coefficient. It greatly simplifies the determination of the magnitude ratio between the two harmonics without the need of third harmonic and cumbersome iterative calculations. The inverse fast Fourier transform of the complex-valued interferogram constructed with the scaling coefficient, first and second harmonics yields a full-range OCT image. Experimental results confirm the effectiveness of the proposed achromatic two-harmonic technique for suppressing the mirror artifacts in SD-OCT images.

  5. Stator Current Harmonic Control with Resonant Controller for Doubly Fed Induction Generator

    DEFF Research Database (Denmark)

    Liu, Changjin; Blaabjerg, Frede; Chen, Wenjie

    2012-01-01

    rotor current control loop for harmonic suppression. The overall control scheme is implemented in dq frame. Based on a mathematical model of the DFIG control system, the effects on system stability using the resonant controller, an analysis of the steady-state error, and the dynamic performance......, are discussed in this paper. Taking these effects into account, the parameters of the resonant controller can be designed and effectively damp the influence from the grid voltage harmonics. As a result, the impacts of the negative sequence fifth- and positive sequence seventh-order voltage harmonics...... harmonics, especially low-order harmonics. This paper proposes a stator current harmonic suppression method using a sixth-order resonant controller to eliminate negative sequence fifth- and positive sequence seventh-order current harmonics. A stator current harmonic control loop is added to the conventional...

  6. An accelerated test method for efflorescence in clay bricks

    International Nuclear Information System (INIS)

    Beggan, John Edward

    1998-01-01

    An investigation into the creation of accelerated efflorescence in clay bricks was undertaken with a view to creating a viable test procedure for determining efflorescence potential. The testing programme incorporated ambient conditions similar to those which promote efflorescence growth in bricks in use. Theoretical investigations into the physical mechanism underlying the creation of efflorescence directed the attempts to accelerate the process. It was found that calcium sulphate efflorescence could not be sufficiently accelerated such that a useful efflorescence test procedure could be proposed. The inability to produce accelerated efflorescence in brick samples was attributed to limitations associated with time dependent salt diffusion in the efflorescence mechanism. The preliminary testing that was undertaken into the creation of efflorescence prompted the use of acid assisted methods to accelerate efflorescence. The acid assisted method that was adopted to provide a possible indication of efflorescence potential relies upon the transformation of low solubility calcium to a more soluble form. The movement of the transformed salt is then induced by cyclic temperature exposure at temperatures similar to those experienced in Spring. The appearance of the transformed calcium salt on the surface of the brick specimen provides an indication of the efflorescence potential. Brick piers constructed on an exposed site and monitored over a 12 month period provided information on the validity of the acid assisted test method. The efflorescence observed on the piers correlated well with that predicted by the acid assisted test, suggesting that the new test has the potential to accurately predict the efflorescence potential of clay bricks Relationships between other properties such as air permeability, sorptivity and tensile strength were investigated such that an alternative method of predicting efflorescence could be achieved. It was found that (within the bounds of the

  7. Testing methods of ECR ion source experimental platform

    International Nuclear Information System (INIS)

    Zhou Changgeng; Hu Yonghong; Li Yan

    2006-12-01

    The principle and structure of ECR ion source experimental platform were introduce. The testing methods of the parameters of single main component and the comprehensive parameters under the condition of certain beam current and beam spot diameter were summarized in process of manufacturing. Some appropriate testing dates were given. The existent questions (the parameters of plasma density in discharge chamber and accurate hydrogen flow, etc. can not be measured in operation) and resolutions were also put forward. (authors)

  8. Towards Automatic Testing of Reference Point Based Interactive Methods

    OpenAIRE

    Ojalehto, Vesa; Podkopaev, Dmitry; Miettinen, Kaisa

    2016-01-01

    In order to understand strengths and weaknesses of optimization algorithms, it is important to have access to different types of test problems, well defined performance indicators and analysis tools. Such tools are widely available for testing evolutionary multiobjective optimization algorithms. To our knowledge, there do not exist tools for analyzing the performance of interactive multiobjective optimization methods based on the reference point approach to communicating ...

  9. A model based security testing method for protocol implementation.

    Science.gov (United States)

    Fu, Yu Long; Xin, Xiao Long

    2014-01-01

    The security of protocol implementation is important and hard to be verified. Since the penetration testing is usually based on the experience of the security tester and the specific protocol specifications, a formal and automatic verification method is always required. In this paper, we propose an extended model of IOLTS to describe the legal roles and intruders of security protocol implementations, and then combine them together to generate the suitable test cases to verify the security of protocol implementation.

  10. Standard Test Method for Normal Spectral Emittance at Elevated Temperatures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1972-01-01

    1.1 This test method describes a highly accurate technique for measuring the normal spectral emittance of electrically conducting materials or materials with electrically conducting substrates, in the temperature range from 600 to 1400 K, and at wavelengths from 1 to 35 μm. 1.2 The test method requires expensive equipment and rather elaborate precautions, but produces data that are accurate to within a few percent. It is suitable for research laboratories where the highest precision and accuracy are desired, but is not recommended for routine production or acceptance testing. However, because of its high accuracy this test method can be used as a referee method to be applied to production and acceptance testing in cases of dispute. 1.3 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this stan...

  11. Test methods for determining asphaltene stability in crude oils

    Energy Technology Data Exchange (ETDEWEB)

    Asomaning, S. [Baker Petrolite, Sugar Land, TX (United States)

    2001-07-01

    The development of test methods for the determination of the stability of asphaltenes in crude oils was rendered necessary, due to the high cost of remediating asphaltene deposition in harsh production environments, namely the underwater systems in offshore deepwater. The Oliensis Spot Test, two saturates, aromatics, resins and asphaltenes (SARA)-based screens (the Colloidal Instability Index and Asphaltene-Resin ratio), a solvent titration method with near infrared radiation (NIR) solids detection, and live oil depressurization were used for the purposes of this study, to predict the stability of asphaltenes in crude oils with different API gravity. A complete description of the test methods was provided, and the experimental data obtained as a result was presented. Correlation with data on the deposition histories of the oils was used to validate the experimental stability data. The author discussed the effectiveness of the different tests for the prediction of the stability of asphaltenes in crude oils. The prediction of a crude oil's propensity towards asphaltene precipitation was more accurate with the Colloidal Instability Index and the solvent titration method. Live oil depressurization proved to be very effective for the prediction of the stability of asphaltenes for light oils, where most stability tests fail. tabs., 31 figs.

  12. Evaluation of clinical methods for peroneal muscle testing.

    Science.gov (United States)

    Sarig-Bahat, Hilla; Krasovsky, Andrei; Sprecher, Elliot

    2013-03-01

    Manual muscle testing of the peroneal muscles is well accepted as a testing method in musculoskeletal physiotherapy for the assessment of the foot and ankle. The peroneus longus and brevis are primary evertors and secondary plantar flexors of the ankle joint. However, some international textbooks describe them as dorsi flexors, when instructing peroneal muscle testing. The identified variability raised a question whether these educational texts are reflected in the clinical field. The purposes of this study were to investigate what are the methods commonly used in the clinical field for peroneal muscle testing and to evaluate their compatibility with functional anatomy. A cross-sectional study was conducted, using an electronic questionnaire sent to 143 Israeli physiotherapists in the musculoskeletal field. The survey questioned on the anatomical location of manual resistance and the combination of motions resisted. Ninety-seven responses were received. The majority (69%) of respondents related correctly to the peronei as evertors, but asserted that resistance should be located over the dorsal aspect of the fifth metatarsus, thereby disregarding the peroneus longus. Moreover, 38% of the respondents described the peronei as dorsi flexors, rather than plantar flexors. Only 2% selected the correct method of resisting plantarflexion and eversion at the base of the first metatarsus. We consider this technique to be the most compatible with the anatomy of the peroneus longus and brevis. The Fisher-Freeman-Halton test indicated that there was a significant relationship between responses on the questions (P = 0.0253, 95% CI 0.0249-0.0257), thus justifying further correspondence analysis. The correspondence analysis found no clustering of the answers that were compatible with anatomical evidence and were applied in the correct technique, but did demonstrate a common error, resisting dorsiflexion rather than plantarflexion, which was in agreement with the described

  13. A Fuzzy Logic Based Method for Analysing Test Results

    Directory of Open Access Journals (Sweden)

    Le Xuan Vinh

    2017-11-01

    Full Text Available Network operators must perform many tasks to ensure smooth operation of the network, such as planning, monitoring, etc. Among those tasks, regular testing of network performance, network errors and troubleshooting is very important. Meaningful test results will allow the operators to evaluate network performanceof any shortcomings and to better plan for network upgrade. Due to the diverse and mainly unquantifiable nature of network testing results, there is a needs to develop a method for systematically and rigorously analysing these results. In this paper, we present STAM (System Test-result Analysis Method which employs a bottom-up hierarchical processing approach using Fuzzy logic. STAM is capable of combining all test results into a quantitative description of the network performance in terms of network stability, the significance of various network erros, performance of each function blocks within the network. The validity of this method has been successfully demonstrated in assisting the testing of a VoIP system at the Research Instiute of Post and Telecoms in Vietnam. The paper is organized as follows. The first section gives an overview of fuzzy logic theory the concepts of which will be used in the development of STAM. The next section describes STAM. The last section, demonstrating STAM’s capability, presents a success story in which STAM is successfully applied.

  14. Bose gases in one-dimensional harmonic trap

    Indian Academy of Sciences (India)

    dimensional Bose gas confined by a harmonic potential are studied using different ensemble approaches. Combining number theory methods, a new approach is presented to calculate the occupation numbers of different energy levels in ...

  15. Application of the X-in-the-Loop Testing Method in the FCV Hybrid Degree Test

    Directory of Open Access Journals (Sweden)

    Haiyu Gao

    2018-02-01

    Full Text Available With the development of fuel cell vehicle technology, an effective testing method that can be applied to develop and verify the fuel cell vehicle powertrain system is urgently required. This paper presents the X-in-the-Loop (XiL testing method in the fuel cell vehicle (FCV hybrid degree test to resolve the first and key issues for the powertrain system design, and the test process and scenarios were designed. The hybrid degree is redefined into the static hybrid degree for system architecture design and the dynamic hybrid degree for vehicle control strategy design, and an integrated testing platform was introduced and a testing application was implemented by following the designed testing flowchart with two loops. Experimental validations show that the sizing of the FCE (Fuel Cell Engine, battery pack, and traction motor with the powertrain architecture can be determined, the control strategy can be evaluated seamlessly, and a systematic powertrain testing solution can be achieved through the whole development process. This research has developed a new testing platform and proposed a novel testing method on the fuel cell vehicle powertrain system, which will be a contribution to fuel cell vehicle technology and its industrialization.

  16. Standard Test Method for Measuring Binocular Disparity in Transparent Parts

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the amount of binocular disparity that is induced by transparent parts such as aircraft windscreens, canopies, HUD combining glasses, visors, or goggles. This test method may be applied to parts of any size, shape, or thickness, individually or in combination, so as to determine the contribution of each transparent part to the overall binocular disparity present in the total “viewing system” being used by a human operator. 1.2 This test method represents one of several techniques that are available for measuring binocular disparity, but is the only technique that yields a quantitative figure of merit that can be related to operator visual performance. 1.3 This test method employs apparatus currently being used in the measurement of optical angular deviation under Method F 801. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not con...

  17. Progress in Harmonizing Tiered HIV Laboratory Systems: Challenges and Opportunities in 8 African Countries

    Science.gov (United States)

    Williams, Jason; Umaru, Farouk; Edgil, Dianna; Kuritsky, Joel

    2016-01-01

    ABSTRACT In 2014, the Joint United Nations Programme on HIV/AIDS released its 90-90-90 targets, which make laboratory diagnostics a cornerstone for measuring efforts toward the epidemic control of HIV. A data-driven laboratory harmonization and standardization approach is one way to create efficiencies and ensure optimal laboratory procurements. Following the 2008 “Maputo Declaration on Strengthening of Laboratory Systems”—a call for government leadership in harmonizing tiered laboratory networks and standardizing testing services—several national ministries of health requested that the United States Government and in-country partners help implement the recommendations by facilitating laboratory harmonization and standardization workshops, with a primary focus on improving HIV laboratory service delivery. Between 2007 and 2015, harmonization and standardization workshops were held in 8 African countries. This article reviews progress in the harmonization of laboratory systems in these 8 countries. We examined agreed-upon instrument lists established at the workshops and compared them against instrument data from laboratory quantification exercises over time. We used this measure as an indicator of adherence to national procurement policies. We found high levels of diversity across laboratories’ diagnostic instruments, equipment, and services. This diversity contributes to different levels of compliance with expected service delivery standards. We believe the following challenges to be the most important to address: (1) lack of adherence to procurement policies, (2) absence or limited influence of a coordinating body to fully implement harmonization proposals, and (3) misalignment of laboratory policies with minimum packages of care and with national HIV care and treatment guidelines. Overall, the effort to implement the recommendations from the Maputo Declaration has had mixed success and is a work in progress. Program managers should continue efforts to

  18. Progress in Harmonizing Tiered HIV Laboratory Systems: Challenges and Opportunities in 8 African Countries.

    Science.gov (United States)

    Williams, Jason; Umaru, Farouk; Edgil, Dianna; Kuritsky, Joel

    2016-09-28

    In 2014, the Joint United Nations Programme on HIV/AIDS released its 90-90-90 targets, which make laboratory diagnostics a cornerstone for measuring efforts toward the epidemic control of HIV. A data-driven laboratory harmonization and standardization approach is one way to create efficiencies and ensure optimal laboratory procurements. Following the 2008 "Maputo Declaration on Strengthening of Laboratory Systems"-a call for government leadership in harmonizing tiered laboratory networks and standardizing testing services-several national ministries of health requested that the United States Government and in-country partners help implement the recommendations by facilitating laboratory harmonization and standardization workshops, with a primary focus on improving HIV laboratory service delivery. Between 2007 and 2015, harmonization and standardization workshops were held in 8 African countries. This article reviews progress in the harmonization of laboratory systems in these 8 countries. We examined agreed-upon instrument lists established at the workshops and compared them against instrument data from laboratory quantification exercises over time. We used this measure as an indicator of adherence to national procurement policies. We found high levels of diversity across laboratories' diagnostic instruments, equipment, and services. This diversity contributes to different levels of compliance with expected service delivery standards. We believe the following challenges to be the most important to address: (1) lack of adherence to procurement policies, (2) absence or limited influence of a coordinating body to fully implement harmonization proposals, and (3) misalignment of laboratory policies with minimum packages of care and with national HIV care and treatment guidelines. Overall, the effort to implement the recommendations from the Maputo Declaration has had mixed success and is a work in progress. Program managers should continue efforts to advance the

  19. Testing of VVER reactor pressure vessels by TOFD method

    International Nuclear Information System (INIS)

    Skala, Z.; Vit, J.

    2002-01-01

    The Time of Flight Diffraction Method (TOFD) - one of the new testing methods capable to obtain the real dimensions of flaws - is presented in the paper.The laboratory experiments on samples with artificial flaws and samples with artificially prepared cracks confirmed the high accuracy of flaw through wall extent sizing by TOFD. This accuracy was confirmed by qualification of methods and systems used by Skoda JS for the in-service inspections of WWER 440 vessel circumferential weld. The qualification also confirmed the ability of TOFD to detect reliably flaws, which can are not reliably detected by standard pulse echo testing. Based on the result of experiments and qualification, the TOFD method shall be used routinely by Skoda JS for the inspection of vessel circumferential welds root area and for sizing of flaws exceeding the acceptance level

  20. An analytic data analysis method for oscillatory slug tests.

    Science.gov (United States)

    Chen, Chia-Shyun

    2006-01-01

    An analytical data analysis method is developed for slug tests in partially penetrating wells in confined or unconfined aquifers of high hydraulic conductivity. As adapted from the van der Kamp method, the determination of the hydraulic conductivity is based on the occurrence times and the displacements of the extreme points measured from the oscillatory data and their theoretical counterparts available in the literature. This method is applied to two sets of slug test response data presented by Butler et al.: one set shows slow damping with seven discernable extremities, and the other shows rapid damping with three extreme points. The estimates of the hydraulic conductivity obtained by the analytic method are in good agreement with those determined by an available curve-matching technique.

  1. Instrumentation and measurement method for the ATLAS test facility

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Byong Jo; Chu, In Chul; Eu, Dong Jin; Kang, Kyong Ho; Kim, Yeon Sik; Song, Chul Hwa; Baek, Won Pil

    2007-03-15

    An integral effect test loop for pressurized water reactors (PWRs), the ATLAS is constructed by thermal-hydraulic safety research division in KAERI. The ATLAS facility has been designed to have the length scale of 1/2 and area scale of 1/144 compared with the reference plant, APR1400 which is a Korean evolution type nuclear reactors. A total 1300 instrumentations is equipped in the ATLAS test facility. In this report, the instrumentation of ATLAS test facility and related measurement methods were introduced.

  2. MCC-15: waste/canister accident testing and analysis method

    International Nuclear Information System (INIS)

    Slate, S.C.; Pulsipher, B.A.; Scott, P.A.

    1985-02-01

    The Materials Characterization Center (MCC) at the Pacific Northwest Laboratory (PNL) is developing standard tests to characterize the performance of nuclear waste forms under normal and accident conditions. As part of this effort, the MCC is developing MCC-15, Waste/Canister Accident Testing and Analysis. MCC-15 is used to test canisters containing simulated waste forms to provide data on the effects of accidental impacts on the waste form particle size and on canister integrity. The data is used to support the design of transportation and handling equipment and to demonstrate compliance with repository waste acceptance specifications. This paper reviews the requirements that led to the development of MCC-15, describes the test method itself, and presents some early results from tests on canisters representative of those proposed for the Defense Waste Processing Facility (DWPF). 13 references, 6 figures

  3. Apparatus and method for defect testing of integrated circuits

    Science.gov (United States)

    Cole, Jr., Edward I.; Soden, Jerry M.

    2000-01-01

    An apparatus and method for defect and failure-mechanism testing of integrated circuits (ICs) is disclosed. The apparatus provides an operating voltage, V.sub.DD, to an IC under test and measures a transient voltage component, V.sub.DDT, signal that is produced in response to switching transients that occur as test vectors are provided as inputs to the IC. The amplitude or time delay of the V.sub.DDT signal can be used to distinguish between defective and defect-free (i.e. known good) ICs. The V.sub.DDT signal is measured with a transient digitizer, a digital oscilloscope, or with an IC tester that is also used to input the test vectors to the IC. The present invention has applications for IC process development, for the testing of ICs during manufacture, and for qualifying ICs for reliability.

  4. Standard test method for measurement of fatigue crack growth rates

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2015-01-01

    1.1 This test method covers the determination of fatigue crack growth rates from near-threshold to Kmax controlled instability. Results are expressed in terms of the crack-tip stress-intensity factor range (ΔK), defined by the theory of linear elasticity. 1.2 Several different test procedures are provided, the optimum test procedure being primarily dependent on the magnitude of the fatigue crack growth rate to be measured. 1.3 Materials that can be tested by this test method are not limited by thickness or by strength so long as specimens are of sufficient thickness to preclude buckling and of sufficient planar size to remain predominantly elastic during testing. 1.4 A range of specimen sizes with proportional planar dimensions is provided, but size is variable to be adjusted for yield strength and applied force. Specimen thickness may be varied independent of planar size. 1.5 The details of the various specimens and test configurations are shown in Annex A1-Annex A3. Specimen configurations other than t...

  5. A novel method for feasibility testing urban sustainable development policies

    Directory of Open Access Journals (Sweden)

    O’Doherty Travis

    2013-01-01

    Full Text Available Policy making to promote more sustainable development is a complex task due in part to the large number of both stakeholders and potential policies. Policy feasibility testing provides a guide to the viability and practicality of policy implementation and forms an important part of an evidence based policy making process. An extensive literature review has identified no standardized approach to feasibility testing. This paper addresses this knowledge gap by describing a novel method using Multi-Criteria Decision Analysis (MCDA for feasibility testing of policies aimed at increasing the sustainability of towns and villages in Ireland. Feasibility results are provided for 40 frequently cited policy interventions tested for 18 settlements in Ireland. Policies were selected in the arenas of transport, food, housing and urban form, energy, waste and water. Policies are feasibility tested through analysis of operational evidence from both quantitative and qualitative data sources. Following testing, policies are ranked in terms of feasibility. This research examines the effectiveness of local and national level policies and the importance of both local community involvement and central government regulation in policy success. The inter-settlement variation in feasibility testing scores prioritises policy selection and aims to reduce cherry-picking of policies to support the viewpoints of the decision maker. Although developed for an Irish urban context the methods described here may have applicability elsewhere.

  6. A method for evaluating horizontal well pumping tests.

    Science.gov (United States)

    Langseth, David E; Smyth, Andrew H; May, James

    2004-01-01

    Predicting the future performance of horizontal wells under varying pumping conditions requires estimates of basic aquifer parameters, notably transmissivity and storativity. For vertical wells, there are well-established methods for estimating these parameters, typically based on either the recovery from induced head changes in a well or from the head response in observation wells to pumping in a test well. Comparable aquifer parameter estimation methods for horizontal wells have not been presented in the ground water literature. Formation parameter estimation methods based on measurements of pressure in horizontal wells have been presented in the petroleum industry literature, but these methods have limited applicability for ground water evaluation and are based on pressure measurements in only the horizontal well borehole, rather than in observation wells. This paper presents a simple and versatile method by which pumping test procedures developed for vertical wells can be applied to horizontal well pumping tests. The method presented here uses the principle of superposition to represent the horizontal well as a series of partially penetrating vertical wells. This concept is used to estimate a distance from an observation well at which a vertical well that has the same total pumping rate as the horizontal well will produce the same drawdown as the horizontal well. This equivalent distance may then be associated with an observation well for use in pumping test algorithms and type curves developed for vertical wells. The method is shown to produce good results for confined aquifers and unconfined aquifers in the absence of delayed yield response. For unconfined aquifers, the presence of delayed yield response increases the method error.

  7. Validation and Verification (V and V) Testing on Midscale Flame Resistant (FR) Test Method

    Science.gov (United States)

    2016-12-16

    materials . The results demonstrated that the Midscale test is a quick and cost-effective method for evaluation of FR performance of design features...standard and novel FR materials and design configurations during fire engulfment. Details of the test method and its development can be found in the...employed in the FRACU is a ripstop fabric blend of 65% FR rayon, 25% para- aramid and 10% nylon. The iCVC material is Nylon/Cotton/Nomex. All three

  8. Natural tracer test simulation by stochastic particle tracking method

    International Nuclear Information System (INIS)

    Ackerer, P.; Mose, R.; Semra, K.

    1990-01-01

    Stochastic particle tracking methods are well adapted to 3D transport simulations where discretization requirements of other methods usually cannot be satisfied. They do need a very accurate approximation of the velocity field. The described code is based on the mixed hybrid finite element method (MHFEM) to calculated the piezometric and velocity field. The random-walk method is used to simulate mass transport. The main advantages of the MHFEM over FD or FE are the simultaneous calculation of pressure and velocity, which are considered as unknowns; the possibility of interpolating velocities everywhere; and the continuity of the normal component of the velocity vector from one element to another. For these reasons, the MHFEM is well adapted for particle tracking methods. After a general description of the numerical methods, the model is used to simulate the observations made during the Twin Lake Tracer Test in 1983. A good match is found between observed and simulated heads and concentrations. (Author) (12 refs., 4 figs.)

  9. Recommendations to harmonize European early warning dosimetry network systems

    Science.gov (United States)

    Dombrowski, H.; Bleher, M.; De Cort, M.; Dabrowski, R.; Neumaier, S.; Stöhlker, U.

    2017-12-01

    After the Chernobyl nuclear power plant accident in 1986, followed by the Fukushima Nuclear power plant accident 25 years later, it became obvious that real-time information is required to quickly gain radiological information. As a consequence, the European countries established early warning network systems with the aim to provide an immediate warning in case of a major radiological emergency, to supply reliable information on area dose rates, contamination levels, radioactivity concentrations in air and finally to assess public exposure. This is relevant for governmental decisions on intervention measures in an emergency situation. Since different methods are used by national environmental monitoring systems to measure area dose rate values and activity concentrations, there are significant differences in the results provided by different countries. Because European and neighboring countries report area dose rate data to a central data base operated on behalf of the European Commission, the comparability of the data is crucial for its meaningful interpretation, especially in the case of a nuclear accident with transboundary implications. Only by harmonizing measuring methods and data evaluation, is the comparability of the dose rate data ensured. This publication concentrates on technical requirements and methods with the goal to effectively harmonize area dose rate monitoring data provided by automatic early warning network systems. The requirements and procedures laid down in this publication are based on studies within the MetroERM project, taking into account realistic technical approaches and tested procedures.

  10. Linear shrinkage test: justification for its reintroduction as a standard South African test method

    CSIR Research Space (South Africa)

    Sampson, LR

    2009-06-04

    Full Text Available Several problems with the linear shrinkage test specified in Method A4 of the THM 1 1979 were addressed as part of this investigation in an effort to improve the alleged poor reproducibility of the test and justify its reintroduction into THM 1. A...

  11. Reusing balanced power flow object components for developing harmonic power flow

    Energy Technology Data Exchange (ETDEWEB)

    Nadarajah, S. [Peninsular Malaysia Electric Utility Co., Kuala Lumpur (Malaysia). Tenaga Nasional Berhad; Nor, K.M.; Abdel-Akher, M. [Malaysia Univ., Kuala Lumpur (Malaysia). Dept. of Electrical Engineering

    2005-07-01

    Harmonic power flows are used to examine the effects of nonlinear loads on power systems. In this paper, component technology was re-used for the development of a harmonic power flow. The object-oriented power system model (OO-PSM) was developed separately from a solution algorithm. Nodes, lines, and transformers were modelled as entity objects by classes. Power flow solution algorithms were modelled as control objects and encapsulated inside independent software components within the power system component software architecture (PS-COM). Both the OO-PSM and the PS-COM of the balanced power flow were re-used for developing the proposed harmonic power flow. A no-interaction hypothesis was used to consider both fundamental voltages and nonlinear device data dependence. A direct solution voltage node method was also used. The accuracy of the method was demonstrated using IEEE 14 bus and 30 bus test systems. It was concluded that component technology can be used to develop harmonic power flow programs. 7 refs., 2 tabs., 9 figs.

  12. NedWind 25 Blade Testing at NREL for the European Standards Measurement and Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    Larwood, S.; Musial, W.; Freebury, G.; Beattie, A.G.

    2001-04-19

    In the mid-90s the European community initiated the Standards, Measurements, and Testing (SMT) program to harmonize testing and measurement procedures in several industries. Within the program, a project was carried out called the European Wind Turbine Testing Procedure Development. The second part of that project, called Blade Test Methods and Techniques, included the United States and was devised to help blade-testing laboratories harmonize their testing methods. This report provides the results of those tests conducted by the National Renewable Energy Laboratory.

  13. Symmetry properties of second harmonics generated by antisymmetric Lamb waves

    Science.gov (United States)

    Zhu, Wujun; Xiang, Yanxun; Liu, Chang-Jun; Deng, Mingxi; Xuan, Fu-Zhen

    2018-03-01

    Symmetry properties of second harmonics generated by antisymmetric primary Lamb waves are systematically studied in this work. In theory, the acoustic field of second harmonic Lamb waves is obtained by using the perturbation approximation and normal modal method, and the energy flux transfer from the primary Lamb waves to second harmonics is mainly explored. Symmetry analyses indicate that either the symmetric or antisymmetric Lamb waves can merely generate the symmetric second harmonics. Finite element simulations are performed on the nonlinear Lamb wave propagation of the antisymmetric A0 mode in the low frequency region. The signals of the second harmonics and the symmetric second harmonic s0 mode are found to be exactly equivalent in the time domain. The relative acoustic nonlinearity parameter A2/A12 oscillates with the propagation distance, and the oscillation amplitude and spatial period are well consistent with the theoretical prediction of the A0-s0 mode pair, which means that only the second harmonic s0 mode is generated by the antisymmetric primary A0 mode. Experiments are further conducted to examine the cumulative generation of symmetric second harmonics for the antisymmetric-symmetric mode pair A3-s6. Results show that A2/A12 increases linearly with the propagation distance, which means that the symmetric second harmonic s6 mode is generated cumulatively by the antisymmetric primary A3 mode. The present investigation systematically corroborates the proposed theory that only symmetric second harmonics can be generated accompanying the propagation of antisymmetric primary Lamb waves in a plate.

  14. The new null testing method for the special optical window

    Science.gov (United States)

    Huang, Changchun

    2009-07-01

    The high speed, high precision and wide range specifications are requirement for the modern aircraft, which the traditional hemispherical dome can't achieve now, and the novel conformal window instead can enhance the aerodynamic performance of the aircraft obviously. To reduce the aerodynamic drag and radar cross-section, the window geometry is generally aspheric in shape. As a result, the involved fabrication and testing processes are much more challenging than that of conventional optics and must be mastered before these windows and systems can be implemented at an acceptable cost and risk. Metrology is one of the critical areas required to advance the conformal window technology. But as the surface of these conformal windows is not the traditional sphere lens, the measurement method for it is infeasible with the conventional optics measurement processes. This paper we express the development of testing technology for the special conformal windows in brief, and emphatically introduces one available novel testing method- a new null testing, and here based on the theory of compensation methods, The principle of Offner's refractive null lens has been extended to test the transmission wavefront through conformal window optics and provide feedback during surface fabrication. a compensator system for the was designed for the conformal window is given which parameters are 100mm for its aperture and two parabolic surface as conformal window, the final residual wavefront error(RMS) of which is less than 1/20λ(λ=632.8nm).

  15. Field Testing of Compartmentalization Methods for Multifamily Construction

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Westford, MA (United States); Lstiburek, J. [Building Science Corporation, Westford, MA (United States)

    2015-03-01

    The 2012 IECC has an airtightness requirement of 3 air changes per hour at 50 Pascals test pressure for both single-family and multifamily construction in Climate Zones 3-8. Other programs (LEED, ASHRAE 189, ASHRAE 62.2) have similar or tighter compartmentalization requirements, driving the need for easier and more effective methods of compartmentalization in multifamily buildings. Builders and practitioners have found that fire-resistance rated wall assemblies are a major source of difficulty in air sealing/compartmentalization, particularly in townhouse construction. This problem is exacerbated when garages are “tucked in” to the units and living space is located over the garages. In this project, Building Science Corporation examined the taping of exterior sheathing details to improve air sealing results in townhouse and multifamily construction, when coupled with a better understanding of air leakage pathways. Current approaches are cumbersome, expensive, time consuming, and ineffective; these details were proposed as a more effective and efficient method. The effectiveness of these air sealing methods was tested with blower door testing, including “nulled” or “guarded” testing (adjacent units run at equal test pressure to null out inter-unit air leakage, or “pressure neutralization”). Pressure diagnostics were used to evaluate unit-to-unit connections and series leakage pathways (i.e., air leakage from exterior, into the fire-resistance rated wall assembly, and to the interior).

  16. Considerations and Methods for Usability Testing with Children

    DEFF Research Database (Denmark)

    Andersen, Malene Hjortboe; Khalid, Md. Saifuddin; Brooks, Eva Irene

    2017-01-01

    of these methods is that they are designed for adults and are not necessarily appropriate to investigations including children. The guiding questions for this systematic literature review are (1) the motivation for conducting usability tests with children, and (2) the kind of methodological, practical, and ethical...

  17. The added value of proficiency tests: choosing the proper method

    NARCIS (Netherlands)

    Nijs, den A.P.M.; Berg, van den W.

    2013-01-01

    To gain insight into the different extraction processes used in laboratories in various European countries and the effect these methods might have on the number of Meloidogyne second-stage juveniles (J2) extracted from soil samples, a ring test with 2 elements was conducted. The first element used

  18. 16 CFR 1509.6 - Component-spacing test method.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Component-spacing test method. 1509.6 Section 1509.6 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT... applied to the wedge perpendicular to the plane of the crib side. ...

  19. Heart rate-based lactate minimum test: a reproducible method.

    NARCIS (Netherlands)

    Strupler, M.; Muller, G.; Perret, C.

    2009-01-01

    OBJECTIVE: To find the individual intensity for aerobic endurance training, the lactate minimum test (LMT) seems to be a promising method. LMTs described in the literature consist of speed or work rate-based protocols, but for training prescription in daily practice mostly heart rate is used. The

  20. Field test of a new Australian method of rangeland monitoring

    Science.gov (United States)

    Suzanne Mayne; Neil West

    2001-01-01

    Managers need more efficient means of monitoring changes on the lands they manage. Accordingly, a new Australian approach was field tested and compared to the Daubenmire method of assessing plant cover, litter, and bare soil. The study area was a 2 mile wide by 30.15 mile long strip, mostly covered by salt desert shrub ecosystem types, centered along the SE boundary of...