  1. A novel compact Tokamak Hard X-ray diagnostic detector

    Institute of Scientific and Technical Information of China (English)

    曹靖; 蒋春雨; 赵艳凤; 杨青巍; 阴泽杰

    2015-01-01

    A compact X-ray detector based on the lutetium yttrium oxyorthosilicate scintillator (LYSO) and silicon photomultiplier (SiPM) has been designed and fabricated for the hard X-ray diagnosis on the HL 2A and HL 2M Tokamak devices. The LYSO scintillator and SiPM in small dimensions were combined in a heat shrink tube package, making the detector compact and integrative. The Monte Carlo particle transport simulation tool, Geant4, was utilized for the design of the detector for the hard X-ray from 10 keV to 200 keV and the best structure scheme was presented. Finally, the detector was used to measure the photon spectrum of a 137Cs gamma source with a pre-amplifier and a multichannel amplitude analyzer. The measured spectrum is consistent with the theoretic spectrum, it has shown that the energy resolution of the detector is less than 14.8%at an energy of 662 keV.

  2. Small pixel CZT detector for hard X-ray spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Matthew David, E-mail: Matt.Wilson@stfc.ac.uk [Science and Technology Facilities Council, Rutherford Appleton Laboratory, Harwell Science and Innovation Campus, Oxfordshire OX11 0QX (United Kingdom); Cernik, Robert [Henry Moseley X-ray Imaging Facility, School of Materials, University of Manchester (United Kingdom); Chen, Henry [Redlen Technologies, Saanichton, British Columbia (Canada); Hansson, Conny [Henry Moseley X-ray Imaging Facility, School of Materials, University of Manchester (United Kingdom); Iniewski, Kris [Redlen Technologies, Saanichton, British Columbia (Canada); Jones, Lawrence L.; Seller, Paul; Veale, Matthew C. [Science and Technology Facilities Council, Rutherford Appleton Laboratory, Harwell Science and Innovation Campus, Oxfordshire OX11 0QX (United Kingdom)

    2011-10-01

    A new small pixel cadmium zinc telluride (CZT) detector has been developed for hard X-ray spectroscopy. The X-ray performance of four detectors is presented and the detectors are analysed in terms of the energy resolution of each pixel. The detectors were made from CZT crystals grown by the travelling heater method (THM) bonded to a 20x20 application specific integrated circuit (ASIC) and data acquisition (DAQ) system. The detectors had an array of 20x20 pixels on a 250 {mu}m pitch, with each pixel gold-stud bonded to an energy resolving circuit in the ASIC. The DAQ system digitised the ASIC output with 14 bit resolution, performing offset corrections and data storage to disc in real time at up to 40,000 frames per second. The detector geometry and ASIC design was optimised for X-ray spectroscopy up to 150 keV and made use of the small pixel effect to preferentially measure the electron signal. A {sup 241}Am source was used to measure the spectroscopic performance and uniformity of the detectors. The average energy resolution (FWHM at 59.54 keV) of each pixel ranged from 1.09{+-}0.46 to 1.50{+-}0.57 keV across the four detectors. The detectors showed good spectral performance and uniform response over almost all pixels in the 20x20 array. A large area 80x80 pixel detector will be built that will utilise the scalable design of the ASIC and the large areas of monolithic spectroscopic grade THM grown CZT that are now available. The large area detector will have the same performance as that demonstrated here.

  3. Small pixel CZT detector for hard X-ray spectroscopy

    Science.gov (United States)

    Wilson, Matthew David; Cernik, Robert; Chen, Henry; Hansson, Conny; Iniewski, Kris; Jones, Lawrence L.; Seller, Paul; Veale, Matthew C.

    2011-10-01

    A new small pixel cadmium zinc telluride (CZT) detector has been developed for hard X-ray spectroscopy. The X-ray performance of four detectors is presented and the detectors are analysed in terms of the energy resolution of each pixel. The detectors were made from CZT crystals grown by the travelling heater method (THM) bonded to a 20×20 application specific integrated circuit (ASIC) and data acquisition (DAQ) system. The detectors had an array of 20×20 pixels on a 250 μm pitch, with each pixel gold-stud bonded to an energy resolving circuit in the ASIC. The DAQ system digitised the ASIC output with 14 bit resolution, performing offset corrections and data storage to disc in real time at up to 40,000 frames per second. The detector geometry and ASIC design was optimised for X-ray spectroscopy up to 150 keV and made use of the small pixel effect to preferentially measure the electron signal. A 241Am source was used to measure the spectroscopic performance and uniformity of the detectors. The average energy resolution (FWHM at 59.54 keV) of each pixel ranged from 1.09±0.46 to 1.50±0.57 keV across the four detectors. The detectors showed good spectral performance and uniform response over almost all pixels in the 20×20 array. A large area 80×80 pixel detector will be built that will utilise the scalable design of the ASIC and the large areas of monolithic spectroscopic grade THM grown CZT that are now available. The large area detector will have the same performance as that demonstrated here.

  4. CZT Detector Development for Hard X-ray Astronomy

    Science.gov (United States)

    Garson, Alfred, III; Li, Q.; Beilicke, M.; Bose, R.; Burger, A.; Dowkonnt, P.; Groza, M.; Simburger, G.; Krawczynski, H.

    2008-05-01

    Cadmium Zinc Telluride (CZT) has proven itself as an excellent material for detection of hard X-rays. Advances in crystal growth have increased the quality and size of available single CZT crystals. We report on our ongoing development and characterization of CZT detector systems. With our dedicated class-100 cleanroom, we fabricate detectors using CZT crystals from different manufactures. Using photolithography and e-beam evaporation, we can produce detectors with different contact designs (pixellated, strip, monolithic, steering grid), contact dimensions (down to 50 microns), and contact materials (In, Ti, Au, etc.) . In addition, we develop ASIC readouts for various CZT detector applications, including our characterization of the detectors. We measure I-V and C-V curves for the detectors as well as their spectroscopic performance. We compare measured results with those from detailed modelling and simulations. The CZT detector systems can then be optimized for applications such as X-ray imaging and polarimetry with satellite or balloon-borne instruments.

  5. Hard X-ray Detector (HXD) on Board Suzaku

    CERN Document Server

    Takahashi, T; Endo, M; Endo, Y; Ezoe, Y; Fukazawa, Y; Hamaya, M; Hirakuri, S; Hong, S; Horii, M; Inoue, H; Isobe, N; Itoh, T; Iyomoto, N; Kamae, T; Kasama, D; Kataoka, J; Kato, H; Kawaharada, M; Kawano, N; Kawashima, K; Kawasoe, S; Kishishita, T; Kitaguchi, T; Kobayashi, Y; Kokubun, M; Kotoku, J; Kouda, M; Kubota, A; Kuroda, Y; Madejski, G; Makishima, K; Masukawa, K; Matsumoto, Y; Mitani, T; Miyawaki, R; Mizuno, T; Mori, K; Mori, M; Murashima, M; Murakami, T; Nakazawa, K; Niko, H; Nomachi, M; Okada, Y; Ohno, M; Oonuki, K; Ota, N; Ozawa, H; Sato, G; Shinoda, S; Sugiho, M; Suzuki, M; Taguchi, K; Takahashi, H; Takahashi, I; Takeda, S; Tamura, K; Tamura, T; Tanaka, T; Tanihata, C; Tashiro, M; Terada, Y; Tominaga, S; Uchiyama, Y; Watanabe, S; Yamaoka, K; Yanagida, T; Yonetoku, D

    2006-01-01

    The Hard X-ray Detector (HXD) on board Suzaku covers a wide energy range from 10 keV to 600 keV by combination of silicon PIN diodes and GSO scintillators. The HXD is designed to achieve an extremely low in-orbit back ground based on a combination of new techniques, including the concept of well-type active shield counter. With an effective area of 142 cm^2 at 20 keV and 273 cm2 at 150 keV, the background level at the sea level reached ~1x10^{-5} cts s^{-1} cm^{-2} keV^{-1} at 30 keV for the PI N diodes, and ~2x10^{-5} cts s^{-1} cm^{-2} keV^{-1} at 100 keV, and ~7x10^{-6} cts s^{-1} cm^{-2} keV^{-1} at 200 keV for the phoswich counter. Tight active shielding of the HXD results in a large array of guard counters surrounding the main detector parts. These anti-coincidence counters, made of ~4 cm thick BGO crystals, have a large effective area for sub-MeV to MeV gamma-rays. They work as an excellent gamma-ray burst monitor with limited angular resolution (~5 degree). The on-board signal-processing system and th...

  6. Pulse pile-up in hard X-ray detector systems. [for solar X-rays

    Science.gov (United States)

    Datlowe, D. W.

    1975-01-01

    When pulse-height spectra are measured by a nuclear detection system at high counting rates, the probability that two or more pulses will arrive within the resolving time of the system is significant. This phenomenon, pulse pile-up, distorts the pulse-height spectrum and must be considered in the interpretation of spectra taken at high counting rates. A computational technique for the simulation of pile-up is developed. The model is examined in the three regimes where (1) the time between pulses is long compared to the detector-system resolving time, (2) the time between pulses is comparable to the resolving time, and (3) many pulses occur within the resolving time. The technique is used to model the solar hard X-ray experiment on the OSO-7 satellite; comparison of the model with data taken during three large flares shows excellent agreement. The paper also describes rule-of-thumb tests for pile-up and identifies the important detector design factors for minimizing pile-up, i.e., thick entrance windows and short resolving times in the system electronics.

  7. Calibration of a time-resolved hard-x-ray detector using radioactive sources

    Science.gov (United States)

    Stoeckl, C.; Theobald, W.; Regan, S. P.; Romanofsky, M. H.

    2016-11-01

    A four-channel, time-resolved, hard x-ray detector (HXRD) has been operating at the Laboratory for Laser Energetics for more than a decade. The slope temperature of the hot-electron population in direct-drive inertial confinement fusion experiments is inferred by recording the hard x-ray radiation generated in the interaction of the electrons with the target. Measuring the energy deposited by hot electrons requires an absolute calibration of the hard x-ray detector. A novel method to obtain an absolute calibration of the HXRD using single photons from radioactive sources was developed, which uses a thermoelectrically cooled, low-noise, charge-sensitive amplifier.

  8. Low-energy shelf response in thin energy-dispersive X-ray detectors from Compton scattering of hard X-rays

    Science.gov (United States)

    Michel-Hart, N.; Elam, W. T.

    2017-08-01

    Silicon drift detectors have been successfully employed in both soft and hard X-ray spectroscopy. The response function to incident radiation at soft X-ray levels has been well studied and modeled, but less research has been published on response functions for these detectors to hard X-ray input spectra above 20 keV. When used with hard X-ray sources a significant low energy, non-peak response exists which can adversely affect detection limits for lighter elements in, for example, X-ray fluorescence spectroscopy. We present a numerical model that explains the non-peak response function of silicon drift detectors to hard X-rays based on incoherent Compton scattering within the detector volume. Experimental results are presented and numerically compared to model results.

  9. HEXITEC: A Next Generation Hard X-ray Detector for Solar Observations

    Science.gov (United States)

    Ryan, Daniel; Christe, Steven; Shih, Albert; Inglis, Andrew R.; Gregory, Kyle; Baumgartner, Wayne H.; Gaskin, Jessica; Wilson-Hodge, Colleen; Seller, Paul; Wilson, Matthew; Veale, Matthew C.; Panessa, Marco

    2016-05-01

    There is an increasing demand in solar physics for high resolution X-ray spectroscopic imaging. Such observations would present ground-breaking opportunities to study the poorly understood high energy processes in the solar corona such as solar flares, coronal heating, etc. However, such observations require a new breed of solid-state detectors sensititve to high energy X-rays with fine independent pixels to subsample the point spread function (PSF) of the X-ray optics. They must also be capable of handling very high count rates as photon fluxes from solar flares often cause pileup in current detectors. The Rutherford Appleton Laboratory (RAL) has recently developed a new Cadmium Telluride (CdTe) detector system, dubbed HEXITEC (High Energy X-ray Imaging Technology). It is an 80x80 array of 250 micron independent pixels sensitive in the 4--80 keV band and capable of a high full frame readout rate of 10 kHz. HEXITEC provides the smallest independently read out pixels currently available, and are well matched to the few arcsecond PSF produced by the current and next generation hard X-ray focusing optics. NASA's Goddard and Marshall Space Flight Centers are collaborating with RAL to develop these detectors for use on future space-borne hard X-ray focusing telescopes. In this poster we show the latest results on HEXITEC's imaging capability, high read out rate, and energy sensitivity and reveal it to be ideal for such future instruments. The potential observations obtained by combining HEXITEC with the next generation of X-ray focusing optics could to revolutionize our understanding of high energy processes in the solar corona.

  10. Hard x-ray response of pixellated CdZnTe detectors

    Science.gov (United States)

    Abbene, L.; Del Sordo, S.; Caroli, E.; Gerardi, G.; Raso, G.; Caccia, S.; Bertuccio, G.

    2009-06-01

    In recent years, the development of cadmium zinc telluride (CdZnTe) detectors for x-ray and gamma ray spectrometry has grown rapidly. The good room temperature performance and the high spatial resolution of pixellated CdZnTe detectors make them very attractive in space-borne x-ray astronomy, mainly as focal plane detectors for the new generation of hard x-ray focusing telescopes. In this work, we investigated on the spectroscopic performance of two pixellated CdZnTe detectors coupled with a custom low noise and low power readout application specific integrated circuit (ASIC). The detectors (10×10×1 and 10×10×2 mm3 single crystals) have an anode layout based on an array of 256 pixels with a geometric pitch of 0.5 mm. The ASIC, fabricated in 0.8 μm BiCMOS technology, is equipped with eight independent channels (preamplifier and shaper) and characterized by low power consumption (0.5 mW/channel) and low noise (150-500 electrons rms). The spectroscopic results point out the good energy resolution of both detectors at room temperature [5.8% full width at half maximum (FWHM) at 59.5 keV for the 1 mm thick detector; 5.5% FWHM at 59.5 keV for the 2 mm thick detector) and low tailing in the measured spectra, confirming the single charge carrier sensing properties of the CdZnTe detectors equipped with a pixellated anode layout. Temperature measurements show optimum performance of the system (detector and electronics) at T =10 °C and performance degradation at lower temperatures. The detectors and the ASIC were developed by our collaboration as two small focal plane detector prototypes for hard x-ray multilayer telescopes operating in the 20-70 keV energy range.

  11. In-Orbit Performance of the Hard X-ray Detector on board Suzaku

    CERN Document Server

    Kokubun, M; Takahashi, T; Murakami, T; Tashiro, M; Fukazawa, Y; Kamae, T; Madejski, G M; Nakazawa, K; Yamaoka, K; Terada, Y; Yonetoku, D; Watanabe, S; Tamagawa, T; Mizuno, T; Kubota, A; Isobe, N; Takahashi, I; Sato, G; Takahashi, H; Hong, S; Kawaharada, M; Kawano, N; Mitani, T; Murashima, M; Suzuki, M; Abe, K; Miyawaki, R; Ohno, M; Tanaka, T; Yanagida, T; Itoh, T; Ohnuki, K; Tamura, K; Endo, Y; Hirakuri, S; Hiruta, T; Kitaguchi, T; Kishishita, T; Sugita, S; Takeda, S; Enoto, T; Hirasawa, A; Katsuta, J; Matsumura, S; Onda, K; Sato, M; Ushio, M; Ishikawa, S; Murase, K; Odaka, H; Yaji, Y; Yamada, S; Yamasaki, T; Yuasa, T

    2006-01-01

    The in-orbit performance and calibration of the Hard X-ray Detector (HXD) on board the X-ray astronomy satellite Suzaku are described. Its basic performances, including a wide energy bandpass of 10-600 keV, energy resolutions of ~4 keV (FWHM) at 40 keV and ~11% at 511 keV, and a high background rejection efficiency, have been confirmed by extensive in-orbit calibrations. The long-term gains of PIN-Si diodes have been stable within 1% for half a year, and those of scintillators have decreased by 5-20%. The residual non-X-ray background of the HXD is the lowest among past non-imaging hard X-ray instruments in energy ranges of 15-70 and 150-500 keV. We provide accurate calibrations of energy responses, angular responses, timing accuracy of the HXD, and relative normalizations to the X-ray CCD cameras using multiple observations of the Crab Nebula.

  12. Design and development of hard x-ray imaging detector using scintillator and Si photomultiplier

    Science.gov (United States)

    Goyal, S. K.; Naik, Amisha P.; Mithun, N. P. S.; Vadawale, S. V.; Acharya, Y. B.; Patel, A. R.; Ladiya, T.; Devashrayee, Niranjan M.

    2016-07-01

    There are various astrophysical phenomena which are of great importance and interest such as stellar explosions, Gamma ray bursts etc. There is also a growing interest in exploring the celestial sources in hard X-rays. High sensitive instruments are essential to perform the detailed studies of these cosmic accelerators and explosions. Hard X-ray imaging detectors having high absorption efficiency and mm spatial resolution are the key requirements to locate the generation of these astrophysical phenomenon. We hereby present a detector module which consists of a single CsI scintillation detector of size 15 x 15 x 3 mm3. The photon readout is done using an array of Silicon Photomultipliers (SiPMs). SiPM is a new development in the field of photon detection and can be described as 2D array of small (hundreds of μm2) avalanche photodiodes. We have achieved a spatial resolution of 0.5 mm with our initial setup. By using the array of these detector modules, we can build the detector with a large sensitive area with a very high spatial resolution. This paper presents the experimental details for single detector module using CsI (Tl) scintillator and SiPM and also presents the preliminary results of energy and position measurement. The GEANT4 simulation has also been carried out for the same geometry.

  13. Uncooled Radiation Hard Large Area SiC X-ray and EUV Detectors and 2D Arrays Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This project seeks to design, fabricate, characterize and commercialize large area, uncooled and radiative hard 4H-SiC EUV ? soft X-ray detectors capable of ultra...

  14. CdTe Focal Plane Detector for Hard X-Ray Focusing Optics

    Science.gov (United States)

    Seller, Paul; Wilson, Matthew D.; Veale, Matthew C.; Schneider, Andreas; Gaskin, Jessica; Wilson-Hodge, Colleen; Christe, Steven; Shih, Albert Y.; Inglis, Andrew; Panessa, Marco

    2015-01-01

    The demand for higher resolution x-ray optics (a few arcseconds or better) in the areas of astrophysics and solar science has, in turn, driven the development of complementary detectors. These detectors should have fine pixels, necessary to appropriately oversample the optics at a given focal length, and an energy response also matched to that of the optics. Rutherford Appleton Laboratory have developed a 3-side buttable, 20 millimeter x 20 millimeter CdTe-based detector with 250 micrometer square pixels (80 x 80 pixels) which achieves 1 kiloelectronvolt FWHM (Full-Width Half-Maximum) @ 60 kiloelectronvolts and gives full spectroscopy between 5 kiloelectronvolts and 200 kiloelectronvolts. An added advantage of these detectors is that they have a full-frame readout rate of 10 kilohertz. Working with NASA Goddard Space Flight Center and Marshall Space Flight Center, 4 of these 1 millimeter-thick CdTe detectors are tiled into a 2 x 2 array for use at the focal plane of a balloon-borne hard-x-ray telescope, and a similar configuration could be suitable for astrophysics and solar space-based missions. This effort encompasses the fabrication and testing of flight-suitable front-end electronics and calibration of the assembled detector arrays. We explain the operation of the pixelated ASIC readout and measurements, front-end electronics development, preliminary X-ray imaging and spectral performance, and plans for full calibration of the detector assemblies. Work done in conjunction with the NASA Centers is funded through the NASA Science Mission Directorate Astrophysics Research and Analysis Program.

  15. Compton polarimeter as a focal plane detector for hard X-ray telescope: sensitivity estimation with Geant4 simulations

    Science.gov (United States)

    Chattopadhyay, T.; Vadawale, S. V.; Pendharkar, J.

    2013-04-01

    X-ray polarimetry can be an important tool for investigating various physical processes as well as their geometries at the celestial X-ray sources. However, X-ray polarimetry has not progressed much compared to the spectroscopy, timing and imaging mainly due to the extremely photon-hungry nature of X-ray polarimetry leading to severely limited sensitivity of X-ray polarimeters. The great improvement in sensitivity in spectroscopy and imaging was possible due to focusing X-ray optics which is effective only at the soft X-ray energy range. Similar improvement in sensitivity of polarisation measurement at soft X-ray range is expected in near future with the advent of GEM based photoelectric polarimeters. However, at energies >10 keV, even spectroscopic and imaging sensitivities of X-ray detector are limited due to lack of focusing optics. Thus hard X-ray polarimetry so far has been largely unexplored area. On the other hand, typically the polarisation degree is expected to increase at higher energies as the radiation from non-thermal processes is dominant fraction. So polarisation measurement in hard X-ray can yield significant insights into such processes. With the recent availability of hard X-ray optics (e.g. with upcoming NuSTAR, Astro-H missions) which can focus X-rays from 5 KeV to 80 KeV, sensitivity of X-ray detectors in hard X-ray range is expected to improve significantly. In this context we explore feasibility of a focal plane hard X-ray polarimeter based on Compton scattering having a thin plastic scatterer surrounded by cylindrical array scintillator detectors. We have carried out detailed Geant4 simulation to estimate the modulation factor for 100 % polarized beam as well as polarimetric efficiency of this configuration. We have also validated these results with a semi-analytical approach. Here we present the initial results of polarisation sensitivities of such focal plane Compton polarimeter coupled with the reflection efficiency of present era hard X-ray

  16. HEXITEC: A next generation hard X-ray Detector for Solar Observations

    Science.gov (United States)

    Panessa, M.; Christe, S.; Shih, A.; Gaskin, J.; Wilson, M. D.; Seller, P.; Baumgartner, W.; Inglis, A. R.

    2015-12-01

    High angular resolution HXR optics require detectors with a large number of fine pixels in order to adequately sample the telescope point spread function (PSF) over the entire field of view. Recent developments at the Rutherford Appleton Laboratory (RAL) have resulted in a new hard X-ray (HXR) detector system with the smallest independent pixels currently available, 250 microns. This matches perfectly with the best angular resolution currently achievable by HXR focusing optics which is about 5 arcsec (FWHM). For a SMEX mission with a 15 meter focal length each pixel would cover an angular size of about 3 arcsec thereby subsampling the PSF. Dubbed HEXITEC, for High Energy X-Ray Imaging Technology, this Application Specific Integrated Circuit (ASIC), can be bonded to 1- or 2- mm-thick Cadmium Telluride (CdTe) or Cadmium-Zinc-Telluride (CZT) which provide high efficiency in the HXR region, good energy resolution, low background, low power, and low sensitivity to radiation damage. For solar observations, the ability to handle high counting rates is also extremely desirable. This ASIC can read each pixel 10,000 times per second. The NASA Marshall Space Flight Center (MSFC) and the Goddard Space Flight Center (GSFC) has been working with RAL over the past few years to develop these detectors to be used with HXR focusing telescopes. We present recent progress on this development effort and its capabilities as applied to solar observations.

  17. Improvement of density resolution in short-pulse hard x-ray radiographic imaging using detector stacks

    Science.gov (United States)

    Borm, B.; Gärtner, F.; Khaghani, D.; Neumayer, P.

    2016-09-01

    We demonstrate that stacking several imaging plates (IPs) constitutes an easy method to increase hard x-ray detection efficiency. Used to record x-ray radiographic images produced by an intense-laser driven hard x-ray backlighter source, the IP stacks resulted in a significant improvement of the radiograph density resolution. We attribute this to the higher quantum efficiency of the combined detectors, leading to a reduced photon noise. Electron-photon transport simulations of the interaction processes in the detector reproduce the observed contrast improvement. Increasing the detection efficiency to enhance radiographic imaging capabilities is equally effective as increasing the x-ray source yield, e.g., by a larger drive laser energy.

  18. Improvement of density resolution in short-pulse hard x-ray radiographic imaging using detector stacks

    Energy Technology Data Exchange (ETDEWEB)

    Borm, B.; Gärtner, F.; Khaghani, D. [GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt (Germany); Johann Wolfgang Goethe-Universität, Frankfurt am Main (Germany); Neumayer, P. [GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt (Germany)

    2016-09-15

    We demonstrate that stacking several imaging plates (IPs) constitutes an easy method to increase hard x-ray detection efficiency. Used to record x-ray radiographic images produced by an intense-laser driven hard x-ray backlighter source, the IP stacks resulted in a significant improvement of the radiograph density resolution. We attribute this to the higher quantum efficiency of the combined detectors, leading to a reduced photon noise. Electron-photon transport simulations of the interaction processes in the detector reproduce the observed contrast improvement. Increasing the detection efficiency to enhance radiographic imaging capabilities is equally effective as increasing the x-ray source yield, e.g., by a larger drive laser energy.

  19. Hard X-ray texture measurements with an on-line image plate detector

    CERN Document Server

    Wcislak, L; Tschentscher, T; Klein, H; Bunge, H J

    2001-01-01

    An instrument for diffraction texture measurements in polycrystalline bulk materials using hard X-ray photons from the wiggler beamline BW5 at HASYLAB is described. High-energy photons in the 100 keV regime enable high penetration power in medium-to-high Z materials and the use of Laue diffraction geometry in combination with a two-dimensional area detector allows fast and convenient data collection. Determination of quantitative, high-resolution pole figures with a better angular resolution of 0.1 deg. is attained by the instrument. Profile analysis of the diffraction pattern parameters for each (h k l)-reflection thus provides, in addition to texture data, information about other microstructural quantities, e.g. lattice strain.

  20. The hard X-ray response of the XIS-CCD for Astro-E: qualification of the X-ray CCD detector

    CERN Document Server

    Nishiuchi, M; Awaki, H; Tsuru, T; Sakano, M; Hamaguchi, K; Murakami, H; Tsunemi, H; Hayashida, K; Kitamoto, S; Miyata, E; Dotani, T; Ozaki, M; Bautz, M; Doty, J; Kissel, S; Foster, R; Ricker, G

    1999-01-01

    We report on the hard X-ray response of the CCD detector for the X-ray imaging spectrometer (XIS), to be launched on the next Japanese X-ray Astronomical Satellite, ASTRO-E, in February 2000. XIS is prepared by an international team, comprised of MIT (USA), ISAS, Osaka University and Kyoto University (JAPAN). We have evaluated the X-ray response of the XIS in its high-energy band (1.5-10 keV). Data from the fluorescent line emission of Al, Cl, Ti, Ni, Fe, Zn, Se were used to construct the response function of the CCD detectors. Details of the response function - including the energy-scale, linearity, energy resolution, quantum efficiency -, are given as a function of incident X-ray energy. We find that the tail component of high-energy photopeaks are produced by events with incomplete charge collection. We also conclude that the size of the charge clouds can be estimated using the shapes of the tail components.

  1. Hard X-ray Detector Calibrations for the FOXSI Sounding Rocket

    Science.gov (United States)

    Lopez, A.; Glesener, L.; Buitrago Casas, J. C.; Han, R.; Ishikawa, S. N.; Christe, S.; Krucker, S.

    2015-12-01

    In the study of high-energy solar flares, detailed X-ray images and spectra of the Sun are required. The Focusing Optics X-ray Solar Imager (FOXSI) sounding rocket experiment is used to test direct-focusing X-ray telescopes and Double-sided Silicon Strip Detectors (DSSD) for solar flare study and to further understand coronal heating. The measurement of active region differential emission measures, flare temperatures, and possible quiet-Sun emission requires a precisely calibrated spectral response. This poster describes recent updates in the calibration of FOXSI's DSSDs based on new calibration tests that were performed after the second flight. The gain for each strip was recalculated using additional radioactive sources. Additionally, the varying strip sensitivity across the detectors was investigated and based on these measurements, the flight images were flatfielded. These improvements lead to more precise X-ray data for future FOXSI flights and show promise for these new technologies in imaging the Sun.

  2. The hard X-ray response of epitaxial GaAs detectors

    CERN Document Server

    Owens, A; Kraft, S; Peacock, A; Nenonen, S; Andersson, H

    2000-01-01

    We report on hard X-ray measurements with two epitaxial GaAs detectors of active areas 2.22 mm sup 2 and thicknesses 40 and 400 mu m at the ESRF and HASYLAB synchrotron research facilities. The detectors were fabricated using high-purity material and in spite of an order of magnitude difference in depletion depths, they were found to have comparable performances with energy resolutions at -45 deg. C of approx 1 keV fwhm at 7 keV rising to approx 2 keV fwhm at 200 keV and noise floors in the range 1-1.5 keV. At energies <30 keV, the energy resolution was dominated by leakage current and electromagnetic pick-up, while at the highest energies measured, the resolutions approach the expected Fano limit (e.g., approx 1 keV near 200 keV). Both detectors are remarkably linear, with average rms non-linearities of 0.2% over the energy range 10-60 keV, which, taken in conjunction with Monte-Carlo results indicate that charge collection efficiencies must be in excess of 98%. This is consistent with material science me...

  3. Multipixel characterization of imaging CZT detectors for hard x-ray imaging and spectroscopy

    Science.gov (United States)

    Vadawale, Santosh V.; Hong, Jae Sub; Grindlay, Jonathan E.; Williams, Peter; Zhang, Minhua; Bellm, Eric C.; Narita, Tomohiko; Craig, William W.; Parker, Bradford H.; Stahle, Carl M.; Yan, Feng

    2004-10-01

    We report our in-depth study of Cd-Zn-Te (CZT) crystals to determine an optimum pixel and guard band configuration for Hard X-ray imaging and spectroscopy. We tested 20x20x5mm crystals with 8x8 pixels on a 2.46mm pitch. We have studied different types of cathode / anode contacts and different pixel pad sizes. We present the measurements of leakage current as well as spectral response for each pixel. Our I-V measurement setup is custom designed to allow automated measurements of the I-V curves sequentially for all 64 pixels, whereas the radiation properties measurement setup allows for interchangeable crystals with the same XAIM3.2 ASIC readout from IDEAS. We have tested multiple crystals of each type, and each crystal in different positions to measure the variation between individual crystals and variation among the ASIC channels. We also compare the same crystals with and without a grounded guard band deposited on the crystal side walls vs. a floating guard band and compare results to simulations. This study was carried out to find the optimum CZT crystal configuration for prototype detectors for the proposed Black-Hole Finder mission, EXIST.

  4. Development of Small-Pixel CZT Detectors for Future High-Resolution Hard X-ray Missions

    Science.gov (United States)

    Beilicke, Matthias

    Owing to recent breakthroughs in grazing incidence mirror technology, next-generation hard X-ray telescopes will achieve angular resolutions of between 5 and 10 arc seconds - about an order of magnitude better than that of the NuSTAR hard X-ray telescope. As a consequence, the next generation of hard X-ray telescopes will require pixelated hard X- ray detectors with pixels on a grid with a lattice constant of between 120 and 240 um. Additional detector requirements include a low energy threshold of less than 5 keV and an energy resolution of less than 1 keV. The science drivers for a high angular-resolution hard X-ray mission include studies and measurements of black hole spins, the cosmic evolution of super-massive black holes, AGN feedback, and the behavior of matter at very high densities. We propose a R&D research program to develop, optimize and study the performance of 100-200 um pixel pitch CdTe and Cadmium Zinc Telluride (CZT) detectors of 1-2 mm thickness. Our program aims at a comparison of the performance achieved with CdTe and CZT detectors, and the optimization of the pixel, steering grid, and guard ring anode patterns. Although these studies will use existing ASICs (Application Specific Integrated Circuits), our program also includes modest funds for the development of an ultra-low noise ASIC with a 2-D grid of readout pads that can be directly bonded to the 100-200 um pixel pitch CdTe and CZT detectors. The team includes the Washington University group (Prof. M. Beilicke and Co-I Prof. H.S.W. Krawczynski et al.), and co-investigator G. De Geronimo at Brookhaven National Laboratory (BNL). The Washington University group has a 10 year track record of innovative CZT detector R&D sponsored by the NASA Astronomy and Physics Research and Analysis (APRA) program. The accomplishments to date include the development of CZT detectors with pixel pitches between 350 um and 2.5 mm for the ProtoExist, EXIST, and X-Calibur hard X-ray missions with some of the best

  5. Trends in hard X-ray fluorescence mapping: environmental applications in the age of fast detectors.

    Science.gov (United States)

    Lombi, E; de Jonge, M D; Donner, E; Ryan, C G; Paterson, D

    2011-06-01

    Environmental samples are extremely diverse but share a tendency for heterogeneity and complexity. This heterogeneity poses methodological challenges when investigating biogeochemical processes. In recent years, the development of analytical tools capable of probing element distribution and speciation at the microscale have allowed this challenge to be addressed. Of these available tools, laterally resolved synchrotron techniques such as X-ray fluorescence mapping are key methods for the in situ investigation of micronutrients and inorganic contaminants in environmental samples. This article demonstrates how recent advances in X-ray fluorescence detector technology are bringing new possibilities to environmental research. Fast detectors are helping to circumvent major issues such as X-ray beam damage of hydrated samples, as dwell times during scanning are reduced. They are also helping to reduce temporal beamtime requirements, making particularly time-consuming techniques such as micro X-ray fluorescence (μXRF) tomography increasingly feasible. This article focuses on μXRF mapping of nutrients and metalloids in environmental samples, and suggests that the current divide between mapping and speciation techniques will be increasingly blurred by the development of combined approaches.

  6. Design and Testing of a Prototype Pixellated CZT Detector and Shield for Hard X-Ray Astronomy

    OpenAIRE

    Bloser, P. F.; Grindlay, J.E.; Narita, T; Jenkins, J. A.

    1999-01-01

    We report on the design and laboratory testing of a prototype imaging CZT detector intended for balloon flight testing in April 2000. The detector tests several key techniques needed for the construction of large-area CZT arrays, as required for proposed hard X-ray astronomy missions. Two 10 mm x 10 mm x 5 mm CZT detectors, each with a 4 x 4 array of 1.9 mm pixels on a 2.5 mm pitch, will be mounted in a ``flip-chip'' fashion on a printed circuit board carrier card; the detectors will be place...

  7. FOXSI: Properties of optics and detectors for hard-X rays

    Science.gov (United States)

    Camilo Buitrago-Casas, Juan; Glesener, Lindsay; Christe, Steven; Krucker, Sam; Ishikawa, Shin-nosuke; Foster, Natalie

    2015-04-01

    The Focusing Optics X-ray Solar Imager (FOXSI) is a state-of-the-art direct focusing X-ray telescope designed to observe the Sun. This experiment completed its second flight onboard a sounding rocket last December 11, 2014 from the White Sands Missile Range in New Mexico. The optics use a set of iridium-coated nickel/cobalt mirrors made using a replication technique based on an electroformed perfect polished surface. Since this technique creates full shells that no need to be co-aligned with other segments, an angular resolution of up to ~5 arcsec is gotten. The FOXSI focal plane consists of seven double-sided strip detectors. Five Silicon and 2 CdTe detectors were used during the second flight.We present on various properties of Wolter-I optics that are applicable to solar HXR observation, including ray-tracing simulations of the single-bounce (“ghost ray”) patterns from sources outside the field of view and angular resolution for different source angles and effective area measurements of the FOXSI optics. We also present the detectors calibration results, paying attention to energy resolution (~0.5 keV), energy thresholds (~4-15 keV for Silicon and ~4-20 keV for CdTe detectors), and spatial coherence of these values over the entire detector.

  8. Construction and Testing of a Pixellated CZT Detector and Shield for a Hard X-ray Astronomy Balloon Flight

    OpenAIRE

    Bloser, P. F.; Narita, T; Jenkins, J. A.; Grindlay, J.E.

    2000-01-01

    We report on the construction and laboratory testing of pixellated CZT detectors mounted in a flip-chip, tiled fashion and read out by an ASIC, as required for proposed hard X-ray astronomy missions. Two 10 mm x 10 mm x 5 mm detectors were fabricated, one out of standard eV Products high-pressure Bridgman CZT and one out of IMARAD horizontal Bridgman CZT. Each was fashioned with a 4 x 4 array of gold pixels on a 2.5 mm pitch with a surrounding guard ring. The detectors were mounted side by si...

  9. The hard X-ray response of a large area HgI sub 2 detector

    CERN Document Server

    Owens, A; Bavdaz, M; Berg, L V D; Peacock, A; Puig, A

    2002-01-01

    We summarise the results of a number of X-ray measurements on a 1.06 cm sup 2 , 0.18 cm thick HgI sub 2 detector carried out at the European Synchrotron Research Facility at Grenoble, France. The detector energy response function was found to be linear over the energy range 8-27 keV with an average rms non-linearity of 0.6%, consistent with statistics. At room temperature, under full area illumination, the FWHM energy resolution was 1.4 keV at 5.9 keV rising to 3.9 keV at 59.54 keV. Under pencil beam illumination, the measured energy resolution at 8 keV was 1.4 keV FWHM at a detector temperature of 9 deg. C. Using a 50x50 mu m sup 2 10 keV monoenergetic X-ray beam, the spatial uniformity of the detector response was determined by a raster scan technique to be at the +-5% level.

  10. Construction and testing of a pixellated CZT detector and shield for a hard x-ray astronomy balloon flight

    Science.gov (United States)

    Bloser, Peter F.; Narita, Tomohiko; Jenkins, Jonathan A.; Grindlay, Jonathan E.

    2000-12-01

    We report on the construction and laboratory testing of pixellated CZT detectors mounted in a flip-chip, tiled fashion and read out by an ASIC, as required for proposed hard X-ray astronomy missions. Two 10 mm X 10 mm X 5 mm detectors were fabricated, one out of standard eV Products high-pressure Bridgman CZT and one out of IMARAD horizontal Bridgman CZT. Each was fashioned with a 4 X 4 array of gold pixels on 2.5 mm pitch with a surrounding guard ring. The detectors were mounted side by side on a carrier card, such that the pixel pitch was preserved, and read out by a 32-channel VA-TA ASIC from IDE AS Corp. controlled by a PC/104 single-board computer. A passive shield/collimator surrounded by plastic scintillator encloses the detectors on five sides and provides an approximately 40 degree field of view. Thus this experiment tests key techniques required for future hard X-ray survey instruments. The experiment was taken to Ft. Sumner, NM in May 2000 in preparation for a scientific balloon flight aboard the joint Harvard-MSFC EXITE2/HERO payload. Although we did not receive a flight opportunity, and are currently scheduled to fly in September 2000, we present our calibration data in the flight configuration together with data analysis techniques and simulations of the expected flight background spectrum.

  11. Construction and Testing of a Pixellated CZT Detector and Shield for a Hard X-ray Astronomy Balloon Flight

    CERN Document Server

    Bloser, P F; Jenkins, J A; Grindlay, J E

    2000-01-01

    We report on the construction and laboratory testing of pixellated CZT detectors mounted in a flip-chip, tiled fashion and read out by an ASIC, as required for proposed hard X-ray astronomy missions. Two 10 mm x 10 mm x 5 mm detectors were fabricated, one out of standard eV Products high-pressure Bridgman CZT and one out of IMARAD horizontal Bridgman CZT. Each was fashioned with a 4 x 4 array of gold pixels on a 2.5 mm pitch with a surrounding guard ring. The detectors were mounted side by side on a carrier card, such that the pixel pitch was preserved, and read out by a 32-channel VA-TA ASIC from IDE AS Corp. controlled by a PC/104 single-board computer. A passive shield/collimator surrounded by plastic scintillator encloses the detectors on five sides and provides a ~40deg field of view. Thus this experiment tests key techniques required for future hard X-ray survey instruments. The experiment was taken to Ft Sumner, NM in May 2000 in preparation for a scientific balloon flight aboard the joint Harvard-MSFC...

  12. Multipixel characterization of imaging CZT detectors for hard X-ray imaging and spectroscopy

    CERN Document Server

    Vadawale, S V; Grindlay, J; Williams, P; Zhang, M; Bellm, E C; Narita, T; Craig, W; Parker, B; Stahle, C; Yan, F; Yan, Feng

    2004-01-01

    We report our in-depth study of Cd-Zn-Te (CZT) crystals to determine an optimum pixel and guard band configuration for Hard X-ray imaging and spectroscopy. We tested 20x20x5mm crystals with 8x8 pixels on a 2.46mm pitch. We have studied different types of cathode / anode contacts and different pixel pad sizes. We present the measurements of leakage current as well as spectral response for each pixel. Our I-V measurement setup is custom designed to allow automated measurements of the I-V curves sequentially for all 64 pixels, whereas the radiation properties measurement setup allows for interchangeable crystals with the same XAIM3.2 ASIC readout from IDEAS. We have tested multiple crystals of each type, and each crystal in different positions to measure the variation between individual crystals and variation among the ASIC channels. We also compare the same crystals with and without a grounded guard band deposited on the crystal side walls vs. a floating guard band and compare results to simulations. This study...

  13. Semiconductor X-ray detectors

    CERN Document Server

    Lowe, Barrie Glyn

    2014-01-01

    Identifying and measuring the elemental x-rays released when materials are examined with particles (electrons, protons, alpha particles, etc.) or photons (x-rays and gamma rays) is still considered to be the primary analytical technique for routine and non-destructive materials analysis. The Lithium Drifted Silicon (Si(Li)) X-Ray Detector, with its good resolution and peak to background, pioneered this type of analysis on electron microscopes, x-ray fluorescence instruments, and radioactive source- and accelerator-based excitation systems. Although rapid progress in Silicon Drift Detectors (SDDs), Charge Coupled Devices (CCDs), and Compound Semiconductor Detectors, including renewed interest in alternative materials such as CdZnTe and diamond, has made the Si(Li) X-Ray Detector nearly obsolete, the device serves as a useful benchmark and still is used in special instances where its large, sensitive depth is essential. Semiconductor X-Ray Detectors focuses on the history and development of Si(Li) X-Ray Detect...

  14. Imaging in Hard X-ray Astronomy

    CERN Document Server

    Li Ti Pei

    2002-01-01

    The energy range of hard X-rays is a key waveband to the study of high energy processes in celestial objects, but still remains poorly explored. In contrast to direct imaging methods used in the low energy X-ray and high energy gamma-ray bands, currently imaging in the hard X-ray band is mainly achieved through various modulation techniques. A new inversion technique, the direct demodulation method, has been developed since early 90s. With this technique, wide field and high resolution images can be derived from scanning data of a simple collimated detector. The feasibility of this technique has been confirmed by experiment, balloon-borne observation and analyzing simulated and real astronomical data. Based the development of methodology and instrumentation, a high energy astrophysics mission -- Hard X-ray Modulation Telescope (HXMT) has been proposed and selected in China for a four-year Phase-A study. The main scientific objectives are a full-sky hard X-ray (20-200 keV) imaging survey and high signal-to-noi...

  15. Design and Testing of a Prototype Pixellated CZT Detector and Shield for Hard X-Ray Astronomy

    CERN Document Server

    Bloser, P F; Narita, T; Jenkins, J A

    1999-01-01

    We report on the design and laboratory testing of a prototype imaging CZT detector intended for balloon flight testing in April 2000. The detector tests several key techniques needed for the construction of large-area CZT arrays, as required for proposed hard X-ray astronomy missions. Two 10 mm x 10 mm x 5 mm CZT detectors, each with a 4 x 4 array of 1.9 mm pixels on a 2.5 mm pitch, will be mounted in a ``flip-chip'' fashion on a printed circuit board carrier card; the detectors will be placed 0.3 mm apart in a tiled configuration such that the pixel pitch is preserved across both crystals. One detector is eV Products high-pressure Bridgman CZT, and the other is IMARAD horizontal Bridgman material. Both detectors are read out by a 32-channel VA-TA ASIC controlled by a PC/104 single-board computer. A passive shield/collimator surrounded by plastic scintillator surrounds the detectors on five sides and provides a ~45 deg field of view. The background spectrum recorded by this instrument will be compared to that...

  16. Hard X-ray polarimetry with position sensitve germanium detectors. Studies of the recombination transitions into highly charged ions

    Energy Technology Data Exchange (ETDEWEB)

    Tashenov, Stanislav

    2005-07-01

    In this work a first study of the photon polarization for the process of radiative recombination has been performed. This was done at the ESR storage ring at GSI for uranium ions colliding with N2 at various collision energies. For this measurement a high purity Ge Pixel Detector with a 4 x 4 segmentation matrix was applied. The investigation was performed at the Gas-jet target of the ESR. The detector was placed at 60 and 90 observation angles. The sensitivity of the Compton scattering effect to the linear polarization of the X-Ray radiation was employed for the polarization measurement. Detailed investigations of the scattering and geometrical effects inside the detector were performed in order to develop a method to interpret the experimental data and extract the degree of the linear polarization in the hard X-Ray regime with a high precision. A special emphasis was given to the geometry of the detector and it's influence on the measured pixel-to-pixel Compton scattering intensities. The developed method enabled to achieve a precision of the order of 10% with the Pixel Detector which is dominated by the statistical uncertainties. The obtained results show a good agreement with the theoretical values derived from the exact relativistic calculations. For the case of the linear polarization of the K-REC photons, the measured data con rm the theoretical prediction that strong depolarization effects occur for high projectile charges in the forward hemisphere. The latter is in disagreement with the nonrelativistic theory which predicts a 100 % polarization regardless of the emission angle. (orig.)

  17. ProtoEXIST: The Development of Advanced Tiled CZT Detector Planes for Wide Field Hard X-Ray Survey Telescope

    Science.gov (United States)

    Allen, Branden; Hong, J.; Grindlay, J.; Barthelmy, S.; Baker, R.

    2011-05-01

    ProtoEXIST is a technology development program for a coded aperture hard X-ray telescope with a large area (1-5 m^2) CZT detector plane for use in a future hard X-ray wide field sky monitor and survey telescope. The successful flight of the ProtoEXIST1 (P1) coded-aperture telescope concluded the first phase of the program on October 9, 2009. The black hole binary Cyg X-1 was imaged and its spectrum measured at the end of the (6h) flight. The P1 detector plane is comprised of a 8x8 array of detector crystal units (DCUs); each made up of a single 20 mm x 20 mm, 5 mm thick Redlen CZT crystal with a 8x8 pixilated anode (pixel pitch of 2.5 mm) bonded to an interposer board connecting each of the individual 64 anode pixels to a single input channel on a RadNET ASIC, forming a 256 cm^2 contiguous CZT imaging array with 4096 individual pixels. P1 was successfully recovered and has undergone further characterization in the interim. The program continues with the ongoing development ProtoEXIST2 (P2) utilizing a closely tiled 8x8 array of DCUs now with a reduced anode pixel pitch of 0.6 mm. Each DCU in P2 will consist of a CZT crystal, identical to that utilized in P1 now with a 32x32 pixelated anode, directly bonded to a single NuSTAR ASIC (Nu-ASIC). The fully assembled P2 imaging detector will be comprised of a semi-contiguous 256x256 array of pixels on 256 cm^2 of CZT. With its finer pixelation the P2 detector plane will enable 5' (FWHM) imaging with a 70 cm focal length and will be flown side-by-side with P1 from Ft. Sumner in the Spring of 2012. Results from the characterization of the P1 detector are discussed as well as current progress in the development of the P2 detector plane.

  18. Development of Tiled Imaging CZT Detectors for Sensitive Wide-Field Hard X-Ray Surveys to EXIST

    Science.gov (United States)

    Grindlay, J.; Hong, J.; Allen, B.; Barthelmy, S.; Baker, R.

    2011-01-01

    Motivated by the proposed EXIST mission, a "medium-class" space observatory to survey black holes and the Early Universe proposed to the 2010 NAS/NRC Astronomy and Astrophysics Decadal Survey, we have developed the first "large" area 256 sq cm close-tiled (0.6 mm gaps) hard X-ray (20-600 keV) imaging detector employing pixelated (2.5 mm) CdZnTe (CZT) detectors, each 2 x 2 x 0.5 cubic cm. We summarize the design, development and operation of this detector array (8 x 8 CZTs) and its performance as the imager for a coded aperture telescope on a high altitude (40 km) balloon flight in October. 2009, as the ProtoEX1STl payload. We then outline our current development of a second-generation imager, ProtcEXIST2. with 0.6 mm pixels on a 32 x 32 array on each CZT, and how it will lead to the ultimate imaging system needed for EXIST. Other applications of this technology will also be mentioned.

  19. Study of electron beams within ISTTOK tokamak by means of a multi-channel Cherenkov detector; their correlation with hard X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Jakubowski, L., E-mail: Lech.Jakubowski@ipj.gov.p [Andrzej Soltan Institute for Nuclear Studies, 05-400 Otwock-Swierk (Poland); Malinowski, K.; Sadowski, M.J.; Zebrowski, J. [Andrzej Soltan Institute for Nuclear Studies, 05-400 Otwock-Swierk (Poland); Plyusnin, V.V. [Association Euratom/IST, Instituto de Plasmas e Fusao Nuclear, Instituto Superior Tecnico, Av. Rovisco Pais, 1049-001 Lisboa (Portugal); Rabinski, M. [Andrzej Soltan Institute for Nuclear Studies, 05-400 Otwock-Swierk (Poland); Fernandes, H.; Silva, C.; Duarte, P. [Association Euratom/IST, Instituto de Plasmas e Fusao Nuclear, Instituto Superior Tecnico, Av. Rovisco Pais, 1049-001 Lisboa (Portugal); Jakubowski, M.J. [Andrzej Soltan Institute for Nuclear Studies, 05-400 Otwock-Swierk (Poland)

    2010-11-11

    The paper describes experimental studies of electron beams emitted from a plasma torus within the ISTTOK tokamak, which were performed by means of a new four-channel detector of the Cherenkov type. A range of electron energy was estimated. There were also measured hard X-rays, and their correlation with the fast run-away electron beams was investigated experimentally.

  20. Continued Development of Small-Pixel CZT and CdTe Detectors for Future High-Angular-Resolution Hard X-ray Missions

    Science.gov (United States)

    Krawczynski, Henric

    The Nuclear Spectroscopic Telescope Array (NuSTAR) Small Explorer Mission was launched in June 2012 and has demonstrated the technical feasibility and high scientific impact of hard X-ray astronomy. We propose to continue our current R&D program to develop finely pixelated semiconductor detectors and the associated readout electronics for the focal plane of a NuSTAR follow-up mission. The detector-ASIC (Application Specific Integrated Circuit) package will be ideally matched to the new generation of low-cost, low-mass X-ray mirrors which achieve an order of magnitude better angular resolution than the NuSTAR mirrors. As part of this program, the Washington University group will optimize the contacts of 2x2 cm^2 footprint Cadmium Zinc Telluride (CZT) and Cadmium Telluride (CdTe) detectors contacted with 100x116 hexagonal pixels at a next-neighbor pitch of 200 microns. The Brookhaven National Laboratory group will design, fabricate, and test the next generation of the HEXID ASIC matched to the new X-ray mirrors and the detectors, providing a low-power 100x116 channel ASIC with extremely low readout noise (i.e. with a root mean square noise of 13 electrons). The detectors will be tested with radioactive sources and in the focal plane of high-angular-resolution X-ray mirrors at the X-ray beam facilities at the Goddard and Marshall Space Flight Centers.

  1. Neutron and X-ray Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Carini, Gabriella [SLAC National Accelerator Lab., Menlo Park, CA (United States); Denes, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gruener, Sol [Cornell Univ., Ithaca, NY (United States); Lessner, Elianne [Dept. of Energy (DOE), Washington DC (United States). Office of Science Office of Basic Energy Sciences

    2012-08-01

    (and two computing hurdles that result from the corresponding increase in data volume) for the detector community to overcome in order to realize the full potential of BES neutron and X-ray facilities. Resolving these detector impediments will improve scientific productivity both by enabling new types of experiments, which will expand the scientific breadth at the X-ray and neutron facilities, and by potentially reducing the beam time required for a given experiment. These research priorities are summarized in the table below. Note that multiple, simultaneous detector improvements are often required to take full advantage of brighter sources. High-efficiency hard X-ray sensors: The fraction of incident particles that are actually detected defines detector efficiency. Silicon, the most common direct-detection X-ray sensor material, is (for typical sensor thicknesses) 100% efficient at 8 keV, 25%efficient at 20 keV, and only 3% efficient at 50 keV. Other materials are needed for hard X-rays. Replacement for 3He for neutron detectors: 3He has long been the neutron detection medium of choice because of its high cross section over a wide neutron energy range for the reaction 3He + n —> 3H + 1H + 0.764 MeV. 3He stockpiles are rapidly dwindling, and what is available can be had only at prohibitively high prices. Doped scintillators hold promise as ways to capture neutrons and convert them into light, although work is needed on brighter, more efficient scintillator solutions. Neutron detectors also require advances in speed and resolution. Fast-framing X-ray detectors: Today’s brighter X-ray sources make time-resolved studies possible. For example, hybrid X-ray pixel detectors, initially developed for particle physics, are becoming fairly mature X-ray detectors, with considerable development in Europe. To truly enable time-resolved studies, higher frame rates and dynamic range are required, and smaller pixel sizes are desirable. High-speed spectroscopic X-ray detectors

  2. Neutron and X-ray Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Carini, Gabriella [SLAC National Accelerator Lab., Menlo Park, CA (United States); Denes, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gruener, Sol [Cornell Univ., Ithaca, NY (United States); Lessner, Elianne [Dept. of Energy (DOE), Washington DC (United States). Office of Science Office of Basic Energy Sciences

    2012-08-01

    (and two computing hurdles that result from the corresponding increase in data volume) for the detector community to overcome in order to realize the full potential of BES neutron and X-ray facilities. Resolving these detector impediments will improve scientific productivity both by enabling new types of experiments, which will expand the scientific breadth at the X-ray and neutron facilities, and by potentially reducing the beam time required for a given experiment. These research priorities are summarized in the table below. Note that multiple, simultaneous detector improvements are often required to take full advantage of brighter sources. High-efficiency hard X-ray sensors: The fraction of incident particles that are actually detected defines detector efficiency. Silicon, the most common direct-detection X-ray sensor material, is (for typical sensor thicknesses) 100% efficient at 8 keV, 25%efficient at 20 keV, and only 3% efficient at 50 keV. Other materials are needed for hard X-rays. Replacement for 3He for neutron detectors: 3He has long been the neutron detection medium of choice because of its high cross section over a wide neutron energy range for the reaction 3He + n —> 3H + 1H + 0.764 MeV. 3He stockpiles are rapidly dwindling, and what is available can be had only at prohibitively high prices. Doped scintillators hold promise as ways to capture neutrons and convert them into light, although work is needed on brighter, more efficient scintillator solutions. Neutron detectors also require advances in speed and resolution. Fast-framing X-ray detectors: Today’s brighter X-ray sources make time-resolved studies possible. For example, hybrid X-ray pixel detectors, initially developed for particle physics, are becoming fairly mature X-ray detectors, with considerable development in Europe. To truly enable time-resolved studies, higher frame rates and dynamic range are required, and smaller pixel sizes are desirable. High-speed spectroscopic X-ray detectors

  3. Instrumentation and data analysis for hard X ray astronomy

    Science.gov (United States)

    Zhang, Shuang Nan

    The current status of hard x ray astronomy is reviewed. The applicability of various hard x ray detectors in such new telescopes are discussed and the current status of hard x ray telescope design is reviewed. Background production mechanisms in hard x ray telescopes are discussed and some techniques for background reduction are also discussed. A simple method for estimating the optimum detector thickness is presented and the use of some detector materials which should minimize the neutron background is proposed. Three imaging techniques are briefly described. A simple discussion about their relative merits has suggested that the rotating modulation collimator (RMC) technique based on an improved detector technique provides the best imaging system. The pulse shape discrimination (PSD) technique is essential for the realization of such new detectors. The basic principles of various PSD methods are made for hard x ray phoswich detector applications. A new fast-veto technique is proposed and may be used in a quadruple phoswich detector system to provide good energy resolution and efficient background rejection. A proposed satellite-borne hard x ray telescope (CHIXSAT), which would use such detectors as its main detection elements, is described. A range of statistical data analysis methods for hard x ray and gamma ray astronomy are studied. Fisher's fact test is found to give the most reliable significance test. Methods for parameter estimation, including upper limit calculations, are described. The sensitivity of a telescope is defined with clear statistical meaning and a method for estimating the sensitivity is derived. A new method, called the chi3-test is proposed to be unbiased and have a very high power for multiple on-off observations, especially in searching for transient sources.

  4. Flight Performance of an advanced CZT Imaging Detector in a Balloon-borne Wide-Field Hard X-ray Telescope - ProtoEXIST1

    CERN Document Server

    Hong, J; Grindlay, J; Barthelemy, S; Baker, R; Garson, A; Krawczynski, H; Apple, J; Cleveland, W H

    2011-01-01

    We successfully carried out the first high-altitude balloon flight of a wide-field hard X-ray coded-aperture telescope ProtoEXIST1, which was launched from the Columbia Scientific Balloon Facility at Ft. Sumner, New Mexico on October 9, 2009. ProtoEXIST1 is the first implementation of an advanced CdZnTe (CZT) imaging detector in our ongoing program to establish the technology required for next generation wide-field hard X-ray telescopes. The CZT detector plane in ProtoEXIST1 consists of an 8 x 8 array of closely tiled 2 cm x 2 cm x 0.5 cm thick pixellated CZT crystals, each with 8 x 8 pixels, covering a 256 cm^2 active area with 2.5 mm pixels. A tungsten mask, mounted at 90 cm above the detector provides shadowgrams of X-ray sources in the 30 - 600 keV band for imaging, allowing a fully coded field of view of 9 Deg x 9 Deg with an angular resolution of 20 arcmin. To reduce the background radiation, the detector is surrounded by semi-graded (Pb/Sn/Cu) passive shields on the four sides all the way to the mask. ...

  5. Hard X-ray Modulation Telescope

    Institute of Scientific and Technical Information of China (English)

    LU Fangjun

    2011-01-01

    The Hard X-ray Modulation Telescope (HXMT) will be China's first astronomical satellite. On board HXMT there are three kinds of slat-collimated telescopes, the High Energy X-ray Telescope (HE, 20-250 keV, 5000 cm^2), the Medium Energy X-ray Telescope (ME, 5-30 keV, 952 cm^2), and the Low Energy X-ray Telescope (LE, 1-15 keV, 384 cm^2).

  6. Fine-pitch CdTe detector for hard X-ray imaging and spectroscopy of the Sun with the FOXSI rocket experiment

    Science.gov (United States)

    Ishikawa, Shin-nosuke; Katsuragawa, Miho; Watanabe, Shin; Uchida, Yuusuke; Takeda, Shin'ichiro; Takahashi, Tadayuki; Saito, Shinya; Glesener, Lindsay; Buitrago-Casas, Juan Camilo; Krucker, Säm.; Christe, Steven

    2016-07-01

    We have developed a fine-pitch hard X-ray (HXR) detector using a cadmium telluride (CdTe) semiconductor for imaging and spectroscopy for the second launch of the Focusing Optics Solar X-ray Imager (FOXSI). FOXSI is a rocket experiment to perform high sensitivity HXR observations from 4 to 15 keV using the new technique of HXR focusing optics. The focal plane detector requires -30°C). Double-sided silicon strip detectors were used for the first FOXSI flight in 2012 to meet these criteria. To improve the detectors' efficiency (66% at 15 keV for the silicon detectors) and position resolution of 75 μm for the second launch, we fabricated double-sided CdTe strip detectors with a position resolution of 60 μm and almost 100% efficiency for the FOXSI energy range. The sensitive area is 7.67 mm × 7.67 mm, corresponding to the field of view of 791'' × 791''. An energy resolution of 1 keV (FWHM) and low-energy threshold of ≈4 keV were achieved in laboratory calibrations. The second launch of FOXSI was performed on 11 December 2014, and images from the Sun were successfully obtained with the CdTe detector. Therefore, we successfully demonstrated the detector concept and the usefulness of this technique for future HXR observations of the Sun.

  7. A Transmissive X-ray Polarimeter Design For Hard X-ray Focusing Telescopes

    CERN Document Server

    Li, Hong; Ji, Jianfeng; Deng, Zhi; He, Li; Zeng, Ming; Li, Tenglin; Liu, Yinong; Heng, Peiyin; Wu, Qiong; Han, Dong; Dong, Yongwei; Lu, Fangjun; Zhang, Shuangnan

    2015-01-01

    The X-ray Timing and Polarization (XTP) is a mission concept for a future space borne X-ray observatory and is currently selected for early phase study. We present a new design of X-ray polarimeter based on the time projection gas chamber. The polarimeter, placed above the focal plane, has an additional rear window that allows hard X-rays to penetrate (a transmission of nearly 80% at 6 keV) through it and reach the detector on the focal plane. Such a design is to compensate the low detection efficiency of gas detectors, at a low cost of sensitivity, and can maximize the science return of multilayer hard X-ray telescopes without the risk of moving focal plane instruments. The sensitivity in terms of minimum detectable polarization, based on current instrument configuration, is expected to be 3% for a 1mCrab source given an observing time of 10^5 s. We present preliminary test results, including photoelectron tracks and modulation curves, using a test chamber and polarized X-ray sources in the lab.

  8. Fine-pitch CdTe detector for hard X-ray imaging and spectroscopy of the Sun with the FOXSI rocket experiment

    CERN Document Server

    Ishikawa, S; Watanabe, S; Uchida, Y; Takeda, S; Takahashi, T; Saito, S; Glesener, L; Buitrago-Casas, J C; Krucker, S; Christe, S

    2016-01-01

    We have developed a fine-pitch hard X-ray (HXR) detector using a cadmium telluride (CdTe) semiconductor for imaging and spectroscopy for the second launch of the Focusing Optics Solar X-ray Imager (FOXSI). FOXSI is a rocket experiment to perform high sensitivity HXR observations from 4-15 keV using the new technique of HXR focusing optics. The focal plane detector requires -30 C). Double-sided silicon strip detectors were used for the first FOXSI flight in 2012 to meet these criteria. To improve the detectors' efficiency (66 at 15 keV for the silicon detectors) and position resolution of 75 um for the second launch, we fabricated double-sided CdTe strip detectors with a position resolution of 60 um and almost 100 % efficiency for the FOXSI energy range. The sensitive area is 7.67 mm x 7.67 mm, corresponding to the field of view of 791'' x 791''. An energy resolution of about 1 keV (FWHM) and low energy threshold of 4 keV were achieved in laboratory calibrations. The second launch of FOXSI was performed on De...

  9. Kinetic Inductance Detectors for X-Ray Spectroscopy

    Science.gov (United States)

    Cecil, T.; Miceli, A.; Gades, L.; Datesman, A.; Quaranta, O.; Yefremenko, V.; Novosad, V.; Mazin, B.

    The lack of efficient x-ray detectors is often the main factor limiting the effective use of ever more powerful synchrotron light sources. Spectroscopic X-ray detectors are used for a wide variety of synchrotron experiments including X-ray micro/nano-probes and X-ray absorption spectroscopy for biology and geophysical applications. The current state-of-art spectroscopic X-ray detectors are semiconductor devices, and their energy resolutions are approaching their theoretical limit of about 100 eV at 6 keV. We describe a detector research and development program to develop the next-generation of high-resolution spectroscopic X-ray detectors using superconducting Kinetic Inductance Detectors (KIDs). With a required energy per charge carrier four orders of magnitude smaller than that of Si, superconducting detectors offer up to two orders of magnitude increase in energy resolution. In addition, KIDs can be optimized for detection of photons ranging in energy from hard X-ray to IR.

  10. Hard x-ray telescope mission

    DEFF Research Database (Denmark)

    Gorenstein, P.; Worrall, D.; Joensen, K.D.

    1996-01-01

    The Hard X-Ray Telescope was selected for study as a possible new intermediate size mission for the early 21st century. Its principal attributes are: (1) multiwavelength observing with a system of focussing telescopes that collectively observe from the UV to over 1 MeV, (2) much higher sensitivity...

  11. CdTe Timepix detectors for single-photon spectroscopy and linear polarimetry of high-flux hard x-ray radiation.

    Science.gov (United States)

    Hahn, C; Weber, G; Märtin, R; Höfer, S; Kämpfer, T; Stöhlker, Th

    2016-04-01

    Single-photon spectroscopy of pulsed, high-intensity sources of hard X-rays - such as laser-generated plasmas - is often hampered by the pileup of several photons absorbed by the unsegmented, large-volume sensors routinely used for the detection of high-energy radiation. Detectors based on the Timepix chip, with a segmentation pitch of 55 μm and the possibility to be equipped with high-Z sensor chips, constitute an attractive alternative to commonly used passive solutions such as image plates. In this report, we present energy calibration and characterization measurements of such devices. The achievable energy resolution is comparable to that of scintillators for γ spectroscopy. Moreover, we also introduce a simple two-detector Compton polarimeter setup with a polarimeter quality of (98 ± 1)%. Finally, a proof-of-principle polarimetry experiment is discussed, where we studied the linear polarization of bremsstrahlung emitted by a laser-driven plasma and found an indication of the X-ray polarization direction depending on the polarization state of the incident laser pulse.

  12. CdTe Timepix detectors for single-photon spectroscopy and linear polarimetry of high-flux hard x-ray radiation

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, C., E-mail: christoph.hahn@uni-jena.de; Höfer, S.; Kämpfer, T. [Helmholtz Institute Jena, 07743 Jena (Germany); Institute of Optics and Quantum Electronics, University of Jena, 07743 Jena (Germany); Weber, G.; Märtin, R. [Helmholtz Institute Jena, 07743 Jena (Germany); GSI Helmholtzzentrum für Schwerionenforschung GmbH, 64291 Darmstadt (Germany); Stöhlker, Th. [Helmholtz Institute Jena, 07743 Jena (Germany); Institute of Optics and Quantum Electronics, University of Jena, 07743 Jena (Germany); GSI Helmholtzzentrum für Schwerionenforschung GmbH, 64291 Darmstadt (Germany)

    2016-04-15

    Single-photon spectroscopy of pulsed, high-intensity sources of hard X-rays — such as laser-generated plasmas — is often hampered by the pileup of several photons absorbed by the unsegmented, large-volume sensors routinely used for the detection of high-energy radiation. Detectors based on the Timepix chip, with a segmentation pitch of 55 μm and the possibility to be equipped with high-Z sensor chips, constitute an attractive alternative to commonly used passive solutions such as image plates. In this report, we present energy calibration and characterization measurements of such devices. The achievable energy resolution is comparable to that of scintillators for γ spectroscopy. Moreover, we also introduce a simple two-detector Compton polarimeter setup with a polarimeter quality of (98 ± 1)%. Finally, a proof-of-principle polarimetry experiment is discussed, where we studied the linear polarization of bremsstrahlung emitted by a laser-driven plasma and found an indication of the X-ray polarization direction depending on the polarization state of the incident laser pulse.

  13. AGN variability at hard X-rays

    CERN Document Server

    Soldi, S; Beckmann, V; Lubinski, P

    2010-01-01

    We present preliminary results on the variability properties of AGN above 20 keV in order to show the potential of the INTEGRAL IBIS/ISGRI and Swift/BAT instruments for hard X-ray timing analysis of AGN. The 15-50 keV light curves of 36 AGN observed by BAT during 5 years show significantly larger variations when the blazar population is considered (average normalized excess variance = 0.25) with respect to the Seyfert one (average normalized excess variance = 0.09). The hard X-ray luminosity is found to be anti-correlated to the variability amplitude in Seyfert galaxies and correlated to the black hole mass, confirming previous findings obtained with different AGN hard X-ray samples. We also present results on the Seyfert 1 galaxy IC 4329A, as an example of spectral variability study with INTEGRAL/ISGRI data. The position of the high-energy cut-off of this source is found to have varied during the INTEGRAL observations, pointing to a change of temperature of the Comptonising medium. For several bright Seyfert...

  14. Observation constraints of the hard X-ray modulation telescope HXMT

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    The hard X-ray modulation telescope HXMT is a low orbit X-ray space telescope whose main science goals are to accomplish a hard X-ray all sky survey and to study timing and spectral characteristics of X-ray sources.HXMT has three kinds of science instruments:the high energy X-ray detector(HE),the medium energy X-ray detector(ME) and the low energy X-ray detector(LE).The observation schedule of HXMT is a key to achieving the science goal of HXMT,and the analysis of the observation constraints is one of the first tasks in making the observation schedule.This paper analyzes how the observation constraints influence the sky visibility and the visible time distribution of X-ray sources and discusses the schedule strategy with regard to the observation constraints.

  15. Polarisation measurements with a CdTe pixel array detector for Laue hard X-ray focusing telescopes

    CERN Document Server

    Caroli, E; Pisa, A; Stephen, J B; Frontera, F; Castanheira, M T D; Sordo, S; Caroli, Ezio; Silva, Rui M. Curado da; Pisa, Alessandro; Stephen, John B.; Frontera, Filippo; Castanheira, Matilde T. D.; Sordo, Stefano del

    2006-01-01

    Polarimetry is an area of high energy astrophysics which is still relatively unexplored, even though it is recognized that this type of measurement could drastically increase our knowledge of the physics and geometry of high energy sources. For this reason, in the context of the design of a Gamma-Ray Imager based on new hard-X and soft gamma ray focusing optics for the next ESA Cosmic Vision call for proposals (Cosmic Vision 2015-2025), it is important that this capability should be implemented in the principal on-board instrumentation. For the particular case of wide band-pass Laue optics we propose a focal plane based on a thick pixelated CdTe detector operating with high efficiency between 60-600 keV. The high segmentation of this type of detector (1-2 mm pixel size) and the good energy resolution (a few keV FWHM at 500 keV) will allow high sensitivity polarisation measurements (a few % for a 10 mCrab source in 106s) to be performed. We have evaluated the modulation Q factors and minimum detectable polaris...

  16. Hard x-ray imaging polarimeter for PolariS

    Science.gov (United States)

    Hayashida, Kiyoshi; Kim, Juyong; Sadamoto, Masaaki; Yoshinaga, Keigo; Gunji, Shuichi; Mihara, Tatehiro; Kishimoto, Yuji; Kubo, Hidetoshi; Mizuno, Tsunefumi; Takahashi, Hiromitsu; Dotani, Tadayasu; Yonetoku, Daisuke; Nakamori, Takeshi; Yoneyama, Tomokage; Ikeyama, Yuki; Kamitsukasa, Fumiyoshi

    2016-07-01

    Hard X-ray imaging polarimeters are developed for the X-ray γ-ray polaeimtery satellite PolariS. The imaging polarimter is scattering type, in which anisotropy in the direction of Compton scattering is employed to measure the hard X-ray (10-80 keV) polarization, and is installed on the focal planes of hard X-ray telescopes. We have updated the design of the model so as to cover larger solid angles of scattering direction. We also examine the event selection algorithm to optimize the detection efficiency of recoiled electrons in plastic scintillators. We succeed in improving the efficiency by factor of about 3-4 from the previous algorithm and criteria for 18-30 keV incidence. For 23 keV X-ray incidence, the recoiled electron energy is about 1 keV. We measured the efficiency to detect recoiled electrons in this case, and found about half of the theoretical limit. The improvement in this efficiency directly leads to that in the detection efficiency. In other words, however, there is still a room for improvement. We examine various process in the detector, and estimate the major loss is primarily that of scintillation light in a plastic scintillator pillar with a very small cross section (2.68mm squared) and a long length (40mm). Nevertheless, the current model provides the MDP of 6% for 10mCrab sources, which are the targets of PolariS.

  17. Developing fine-pixel CdTe detectors for the next generation of high-resolution hard x-ray telescopes

    Science.gov (United States)

    Christe, Steven

    Over the past decade, the NASA Marshall Space Flight Center (MSFC) has been improving the angular resolution of hard X-ray (HXR; 20 "70 keV) optics to the point that we now routinely manufacture optics modules with an angular resolution of 20 arcsec Half Power Diameter (HDP), almost three times the performance of NuSTAR optics (Ramsey et al. 2013; Gubarev et al. 2013a; Atkins et al. 2013). New techniques are currently being developed to provide even higher angular resolution. High angular resolution HXR optics require detectors with a large number of fine pixels in order to adequately sample the telescope point spread function (PSF) over the entire field of view. Excessively over-sampling the PSF will increase readout noise and require more processing with no appreciable increase in image quality. An appropriate level of over-sampling is to have 3 pixels within the HPD. For the HERO mirrors, where the HPD is 26 arcsec over a 6-m focal length converts to 750 μm, the optimum pixel size is around 250 μm. At a 10-m focal length these detectors can support a 16 arcsec HPD. Of course, the detectors must also have high efficiency in the HXR region, good energy resolution, low background, low power requirements, and low sensitivity to radiation damage (Ramsey 2001). The ability to handle high counting rates is also desirable for efficient calibration. A collaboration between Goddard Space Flight Center (GSFC), MSFC, and Rutherford Appleton Laboratory (RAL) in the UK is developing precisely such detectors under an ongoing, funded APRA program (FY2015 to FY2017). The detectors use the RALdeveloped Application Specific Integrated Circuit (ASIC) dubbed HEXITEC, for High Energy X-Ray Imaging Technology. These HEXITEC ASICs can be bonded to 1- or 2- mm-thick Cadmium Telluride (CdTe) or Cadmium-Zinc-Telluride (CZT) to create a fine (250 μm pitch) HXR detector (Jones et al. 2009; Seller et al. 2011). The objectives of this funded effort are to develop and test a HEXITEC

  18. X-Ray Detector Simulations - Oral Presentation

    Energy Technology Data Exchange (ETDEWEB)

    Tina, Adrienne [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2015-08-20

    The free-electron laser at LCLS produces X-Rays that are used in several facilities. This light source is so bright and quick that we are capable of producing movies of objects like proteins. But making these movies would not be possible without a device that can detect the X-Rays and produce images. We need X-Ray cameras. The challenges LCLS faces include the X-Rays’ high repetition rate of 120 Hz, short pulses that can reach 200 femto-seconds, and extreme peak brightness. We need detectors that are compatible with this light source, but before they can be used in the facilities, they must first be characterized. My project was to do just that, by making a computer simulation program. My presentation discusses the individual detectors I simulated, the details of my program, and how my project will help determine which detector is most useful for a specific experiment.

  19. Hard X-ray Timing with EXIST

    CERN Document Server

    Grindlay, J E

    2004-01-01

    The Energetic X-ray Timing Survey Telescope (EXIST) mission concept is under study as the Black Hole Finder Probe (BHFP), one of the three Einstein Probe missions in the Beyond Einstein Program in the current NASA Strategic Plan. EXIST would conduct an all-sky imaging hard X-ray ($\\sim$10-600 keV) survey with unprecedented sensitivity: about 5 $\\times 10^{-13}$ cgs over any factor of 2 bandwidth, or comparable to that achieved at soft X-rays in the ROSAT survey. The proposed angular resolution of 5arcmin, temporal resolution of 10microsec, energy resolution of 1-4 keV over the broad band, and duty cycle of 0.2-0.5 for continuous coverage of any source provide an unprecedented phase space for timing and spectral studies of black holes --from stellar to supermassive, as well as neutron stars and accreting white dwarfs. The large sky coverage allows intrinsically rare events to be studied. One particularly exciting example is the possible detection of tidal disruption of stars near quiescent AGN. Super flares fr...

  20. CZT in Space Based Hard-X-ray Astronomy

    CERN Document Server

    Garson, A; Weidenspointner, G; Novikova, E I; Grindlay, J; Hong, J; Jung, I V

    2006-01-01

    One of the key aspects of a detector material for space-borne hard X-ray and gamma-ray telescopes is the rate of prompt and delayed background events generated inside the material by charged and neutral particles striking the detector. These particles are Cosmic Rays, particles trapped in Earth's magnetic field, and secondaries from Cosmic Ray interacting with the atmosphere and the spacecraft. Here, we present a preliminary study of Cadmium Zinc Telluride (CZT) and its behaviour in space environments. We have used the simulation package MGGPOD to estimate the background of the CZT detectors in the proposed Energetic X-ray Imaging Survey Telescope (EXIST) for possible orbital parameters. The EXIST mission will make use of 6 square meters of 0.5 cm thick CZT detectors to record cosmic X-rays in the energy range from 10 keV to 600 keV. The detectors will be shielded by a fully or partly active shield. For the specific detector and shielding geometry considered here and an orbit with a low (7 deg) inclination, t...

  1. Hard X-ray mirrors for Nuclear Security

    Energy Technology Data Exchange (ETDEWEB)

    Descalle, M. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Brejnholt, N. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hill, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Decker, T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Alameda, J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Soufli, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Pivovaroff, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Pardini, T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-01-07

    Research performed under this LDRD aimed to demonstrate the ability to detect and measure hard X-ray emissions using multilayer X-ray reflective optics above 400 keV, to enable the development of inexpensive and high-accuracy mirror substrates, and to investigate applications of hard X-ray mirrors of interest to the nuclear security community. Experiments conducted at the European Synchrotron Radiation Facility demonstrated hard X-ray mirror reflectivity up to 650 keV for the first time. Hard X-ray optics substrates must have surface roughness under 3 to 4 Angstrom rms, and three materials were evaluated as potential substrates: polycarbonates, thin Schott glass and a new type of flexible glass called Willow Glass®. Chemical smoothing and thermal heating of the surface of polycarbonate samples, which are inexpensive but have poor intrinsic surface characteristics, did not yield acceptable surface roughness. D263 Schott glass was used for the focusing optics of the NASA NuSTAR telescope. The required specialized hardware and process were costly and motivated experiments with a modified non-contact slumping technique. The surface roughness of the glass was preserved and the process yielded cylindrical shells with good net shape pointing to the potential advantage of this technique. Finally, measured surface roughness of 200 and 130 μm thick Willow Glass sheets was between 2 and 2.5 A rms. Additional results of flexibility tests and multilayer deposition campaigns indicated it is a promising substrate for hard X-ray optics. The detection of U and Pu characteristics X-ray lines and gamma emission lines in a high background environment was identified as an area for which X-ray mirrors could have an impact and where focusing optics could help reduce signal to noise ratio by focusing signal onto a smaller detector. Hence the first one twelvetant of a Wolter I focusing optics for the 90 to 140 keV energy range based on aperiodic multilayer coating was designed. Finally

  2. NuSTAR Hard X-ray Optics

    DEFF Research Database (Denmark)

    Koglin, Jason E.; Christensen, Finn Erland; Craig, William W.;

    2005-01-01

    The Nuclear Spectroscopic Telescope Array (NuSTAR) is a small explorer (SMEX) mission currently under an extended Phase A study by NASA. NuSTAR will be the first satellite mission to employ focusing optics in the hard X-ray band (8- 80 keV). Its design eliminates high detector backgrounds, allows...... true imaging, and permits the use of compact high performance detectors. The result: a combination of clarity, sensitivity, and spectral resolution surpassing the largest observatories that have operated in this band by orders of magnitude. We present an overview of the NuSTAR opticsdesign...

  3. Hard x-ray telescope mission

    DEFF Research Database (Denmark)

    Gorenstein, P.; Worrall, D.; Joensen, K.D.

    1996-01-01

    The Hard X-Ray Telescope was selected for study as a possible new intermediate size mission for the early 21st century. Its principal attributes are: (1) multiwavelength observing with a system of focussing telescopes that collectively observe from the UV to over 1 MeV, (2) much higher sensitivity...... and much better angular resolution in the 10 - 100 keV band, and (3) higher sensitivity for detecting gamma ray lines of known energy in the 100 keV to 1 MeV band. This paper emphasizes the mission aspects of the concept study such as the payload configuration and launch vehicle. An engineering team...... at the Marshall Space Center is participating in these two key aspects of the study....

  4. Hard X-Ray Modulation Telescope(HXMT) Mission

    Institute of Scientific and Technical Information of China (English)

    LI Tipei; ZHANG Shuangnan; LU Fangjun

    2006-01-01

    The HXMT mission concept consists of a slat-collimated hard X-ray detector assembly sensitive in 20~250 keV with a collection area of about 5000 cm2. Based on the reconstruction technique by direct demodulation developed in recent years, HXMT is mainly devoted to performing a hard X-ray all-sky imaging survey with both high sensitivity and high spatial resolution. It can also be used to make pointed observations of X-ray sources to study their spectroscopic and temporal properties in details. The main detector of HXMT consists of 18 individual cylindrical NaI(T1)/CsI(Na) phoswich modules, each with anarea of 283.5 cm2 and a field of view of 5.7°× 1.1° (FWHM). Its spatial resolution and position accuracy are 5′ and 1′ by using the direct demodulation in 1994, and in 2000 its feasibility and technical demonstration study was selected as a project under the Major State Basic Research Program of China. In October 2005, this project entered the full design phase and was listed as a candidate for the first dedicated astronomy satellite around 2010. We are now also considering secondary low energy instruments for this satellite.

  5. Observational Aspects of Hard X-ray Polarimetry

    Science.gov (United States)

    Chattopadhyay, Tanmoy

    2016-04-01

    of such hard X-ray telescopes, which may provide sensitive polarization measurements due to flux concentration in hard X-rays with a very low background. On the other hand, such a configuration ensures implementation of an optimized geometry close to an ideal one for the Compton polarimeters. In this context, we initiated the development of a focal plane Compton polarimeter, consisting of a plastic scatterer surrounded by a cylindrical array of CsI(Tl) scintillators. Geant-4 simulations of the planned configuration estimates 1% MDP for a 100 mCrab source in 1 million seconds of exposure. Sensitivity of the instrument is found to be critically dependent on the lower energy detection limit of the plastic scatterer; lower the threshold, better is the sensitivity. In the actual experiment, the plastic is readout by a photomultiplier tube procured from Saint-Gobain. We carried out extensive experiments to characterize the plastic especially for lower energy depositions. The CsI(Tl) scintillators are readout by Si photomultipliers (SiPM). SiPMs are small in size and robust and therefore provide the compactness necessary for the designing of focal plane detectors. Each of the CsI(Tl)-SiPM systems was characterized precisely to estimate their energy threshold and detection probability along the length of the scintillators away from SiPM. Finally, we integrated the Compton polarimeter and tested its response to polarized and unpolarized radiation and compared the experimental results with Geant-4 simulation. Despite the growing realization of the scientific values of X-ray polarimetry and the efforts in developing sensitive X-ray polarimeters, there has not been a single dedicated X-ray polarimetry mission planned in near future. In this scenario, it is equally important to attempt polarization measurements from the existing or planned instruments which are not meant for X-ray polarization measurements but could be sensitive to it. There have been several attempts in past in

  6. Hard X-ray emission from neutron star X-ray binaries

    Energy Technology Data Exchange (ETDEWEB)

    Di Salvo, T.; Santangelo, A.; Segreto, A

    2004-06-01

    In this paper we review our current knowledge of the hard X-ray emission properties of accreting X-ray Binary Pulsars and old accreting neutron stars in Low Mass X-ray Binaries in light of 7 years of BeppoSAX and RXTE observations. The paper is divided in two parts. In the first part we review the more recent findings on the phase-dependent broad band continua and cyclotron resonance scattering features observed in many systems of the X-ray Binary Pulsar class. In the second part we review the hard X-ray emission of LMXRB focussing on the hard X-ray components extending up to energies of a few hundred keV that have been clearly detected in sources of both the atoll and Z classes. The presence and characteristics of these hard emission components are then discussed in relation to source properties and spectral state. We, also, briefly mention models that have been proposed for the hard X-ray emission of neutron star X-ray binaries.

  7. The Hard X-ray Imager (HXI) for the ASTRO-H Mission

    Science.gov (United States)

    Sato, Goro; Kokubun, Motohide; Nakazawa, Kazuhiro; Enoto, Teruaki; Fukazawa, Yasushi; Harayama, Atsushi; Hayashi, Katsuhiro; Kataoka, Jun; Katsuta, Junichiro; Kawaharada, Madoka; Laurent, Philippe; Lebrun, François; Limousin, Olivier; Makishima, Kazuo; Mizuno, Tsunefumi; Mori, Kunishiro; Nakamori, Takeshi; Noda, Hirofumi; Odaka, Hirokazu; Ohno, Masanori; Ohta, Masayuki; Saito, Shinya; Sato, Rie; Tajima, Hiroyasu; Takahashi, Hiromitsu; Takahashi, Tadayuki; Takeda, Shinichiro; Terada, Yukikatsu; Uchiyama, Hideki; Uchiyama, Yasunobu; Watanabe, Shin; Yamaoka, Kazutaka; Yatsu, Yoichi; Yuasa, Takayuki

    2014-07-01

    The 6th Japanese X-ray satellite, ASTRO-H, is scheduled for launch in 2015. The hard X-ray focusing imaging system will observe astronomical objects with the sensitivity for detecting point sources with a brightness of 1/100,000 times fainter than the Crab nebula at > 10 keV. The Hard X-ray Imager (HXI) is a focal plane detector 12 m below the hard X-ray telescope (HXT) covering the energy range from 5 to 80 keV. The HXI is composed of a stacked Si/CdTe semiconductor detector module and surrounding BGO scintillators. The latter work as active shields for efficient reduction of background events caused by cosmic-ray particles, cosmic X-ray background, and in-orbit radiation activation. In this paper, we describe the detector system, and present current status of flight model development, and performance of HXI using an engineering model of HXI.

  8. Hard X-ray telescope using formation flight

    Science.gov (United States)

    Tsunemi, Hiroshi

    2012-07-01

    We are planning to have a hard X-ray telescope using a formation flight (FF) that will cover a large sky area (FFAST: formation flight astronomical survey telescope). In particular, it will focus on the energy range above 10 keV. It consists of two small satellites that will go in FF. One is an X-ray telescope satellite and the other is a detector satellite. Two satellites will be simultaneously launched by a single rocket vehicle into a low earth orbit. They are in FF with a separation of 20m +- 10cm. Two satellites are put into a "relatively circular orbit" so that they are in FF in individual Keplerian orbit. Therefore, we only need a small thruster to compensate the perturbation, which is a quite different point from those employed FF in the past projects (XEUS and SimbolX). Since we can not point to the fixed direction, we will survey the sky. The X-ray telescope satellite carries one super-mirror covering the energy range up to 80 keV. The telescope is 45-cm diameter and its focal length is 20 m. The telescope is a super mirror that has a multi-layer coating covering the energy range up to 80 keV. The detector satellite carries an SDCCD system. The SDCCD is a CCD with a scintillator that is directly attached to the CCD. The CCD chip is fully depleted which can be a back-illuminated CCD. This project, FFAST, will scan a large sky area at hard X-ray region.

  9. Burst Detector X-Ray IIR

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    The Burst Detector X-Ray (BDX) instrument for the Block IIR series of Global Positioning System satellites is described. The BDX instrument can locate and characterize exoatmospheric nuclear detonations by using four sensors consisting of sets of filters over silicon diodes to detect x rays of various energies from the burst. On the BDX-IIR, a fifth sensor with a response spanning those of the other sensors confirms coincidences among the four main channels. The mechanical and electronic features of the BDX-IIR and its sensors are described. The calibrations and the system tests used in flight are presented. The commands for the BDX-IIR are given. The messages sent from the BDX-IIR are described in detail.

  10. Femtosecond X-ray Absorption Spectroscopy at a Hard X-ray Free Electron Laser

    DEFF Research Database (Denmark)

    Lemke, Henrik T.; Bressler, Christian; Chen, Lin X.

    2013-01-01

    X-ray free electron lasers (XFELs) deliver short (<100 fs) and intense (similar to 10(12) photons) pulses of hard X-rays, making them excellent sources for time-resolved studies. Here we show that, despite the inherent instabilities of current (SASE based) XFELs, they can be used for measuring hi...

  11. Design and tests of the hard X-ray polarimeter X-Calibur

    Energy Technology Data Exchange (ETDEWEB)

    Beilicke, M., E-mail: beilicke@physics.wustl.edu [Washington University, St. Louis, MO (United States); Baring, M.G. [Rice University, TX (United States); Barthelmy, S. [Goddard Space Flight Center, MD (United States); Binns, W.R.; Buckley, J.; Cowsik, R.; Dowkontt, P.; Garson, A.; Guo, Q. [Washington University, St. Louis, MO (United States); Haba, Y. [Nagoya University (Japan); Israel, M.H. [Washington University, St. Louis, MO (United States); Kunieda, H. [Nagoya University (Japan); Lee, K. [Washington University, St. Louis, MO (United States); Matsumoto, H.; Miyazawa, T. [Nagoya University (Japan); Okajima, T.; Schnittman, J. [Goddard Space Flight Center, MD (United States); Tamura, K. [Nagoya University (Japan); Tueller, J. [Goddard Space Flight Center, MD (United States); Krawczynski, H. [Washington University, St. Louis, MO (United States)

    2012-11-11

    X-ray polarimetry will give qualitatively new information about high-energy astrophysical sources. We designed, built and tested a hard X-ray polarimeter X-Calibur to be used in the focal plane of the InFOC{mu}S grazing incidence hard X-ray telescope. X-Calibur combines a low-Z Compton scatterer with a CZT detector assembly to measure the polarization of 10-80 keV X-rays making use of the fact that polarized photons Compton scatter preferentially perpendicular to the electric field orientation. X-Calibur achieves a high detection efficiency of order unity.

  12. Hard X-ray Variability of AGN

    CERN Document Server

    Beckmann, V; Courvoisier, T J -L; Gehrels, N; Soldi, S; Tüller, J; Wendt, G

    2007-01-01

    Aims: Active Galactic Nuclei are known to be variable throughout the electromagnetic spectrum. An energy domain poorly studied in this respect is the hard X-ray range above 20 keV. Methods: The first 9 months of the Swift/BAT all-sky survey are used to study the 14 - 195 keV variability of the 44 brightest AGN. The sources have been selected due to their detection significance of >10 sigma. We tested the variability using a maximum likelihood estimator and by analysing the structure function. Results: Probing different time scales, it appears that the absorbed AGN are more variable than the unabsorbed ones. The same applies for the comparison of Seyfert 2 and Seyfert 1 objects. As expected the blazars show stronger variability. 15% of the non-blazar AGN show variability of >20% compared to the average flux on time scales of 20 days, and 30% show at least 10% flux variation. All the non-blazar AGN which show strong variability are low-luminosity objects with L(14-195 keV) < 1E44 erg/sec. Conclusions: Concer...

  13. A Monte Carlo study of x-ray fluorescence in x-ray detectors.

    Science.gov (United States)

    Boone, J M; Seibert, J A; Sabol, J M; Tecotzky, M

    1999-06-01

    Advances in digital x-ray detector systems have led to a renewed interest in the performance of x-ray phosphors and other detector materials. Indirect flat panel x-ray detector and charged coupled device (CCD) systems require a more technologically challenging geometry, whereby the x-ray beam is incident on the front side of the scintillator, and the light produced must diffuse to the back surface of the screen to reach the photoreceptor. Direct detector systems based on selenium have also enjoyed a growing interest, both commercially and academically. Monte Carlo simulation techniques were used to study the x-ray scattering (Rayleigh and Compton) and the more prevalent x-ray fluorescence properties of seven different x-ray detector materials, Gd2O2S, CsI, Se, BaFBr, YTaO4, CaWO4, and ThO2. The redistribution of x-ray energy, back towards the x-ray source, in a forward direction through the detector, and lateral reabsorption in the detector was computed under monoenergetic conditions (1 keV to 130 keV by 1 keV intervals) with five detector thicknesses, 30, 60, 90, 120, and 150 mg/cm2 (Se was studied from 30 to 1000 mg/cm2). The radial distribution (related to the point spread function) of reabsorbed x-ray energy was also determined. Representative results are as follows: At 55 keV, more (31.3%) of the incident x-ray energy escaped from a 90 mg/cm2Gd2O2S detector than was absorbed (27.9%). Approximately 1% of the total absorbed energy was reabsorbed greater than 0.5 mm from the primary interaction, for 90 mg/cm2 CsI exposed at 100 kVp. The ratio of reabsorbed secondary (fluorescence + scatter) radiation to the primary radiation absorbed in the detectors (90 mg/cm2) (S/P) was determined as 10%, 16%, 2%, 12%, 3%, 3%, and 0.3% for a 100 kVp tungsten anode x-ray spectrum, for the Gd2O2S, CsI, Se, BaFBr, YTaO4, CaWO4, and ThO2 detectors, respectively. The results indicate significant x-ray fluorescent escape and reabsorption in common x-ray detectors. These findings

  14. Hard X-ray micro-focusing beamline at SSRF

    Institute of Scientific and Technical Information of China (English)

    张丽丽; 兰旭颖; 毛成文; 王娟; 蒋晖; 郑怡; 董朝晖; 曾乐勇; 李爱国; 闫帅; 蒋升; 杨科; 王华; 何上明; 梁东旭; 张玲; 何燕

    2015-01-01

    The hard X-ray micro-focusing beamline (BL15U1) of SSRF is dedicated to hard X-ray micro/nano-spectrochemical analysis consisting of X-ray fluorescence (XRF), X-ray absorption spectroscopy (XAS) and X-ray diffraction (XRD) techniques. It is one of the most versatile instruments in hard X-ray microscopy sci-ence. Since its commission in 2009, BL15U1 has allocated over 25000 h beamtime for users, and about 700 proposals have been executed. The beamline and the experimental end-station were upgraded for several times to facilitate the users’ experimental needs and make it more convenient to operate. In this paper, we give a review on the beamline, describing its characteristics, recent technical developments, and a few examples of scientific progresses achieved in recent years on BL15U1.

  15. Hard disk drive based microsecond x-ray chopper for characterization of ionization chambers and photodiodes

    Science.gov (United States)

    Müller, O.; Lützenkirchen-Hecht, D.; Frahm, R.

    2015-03-01

    A fast X-ray chopper capable of producing ms long X-ray pulses with a typical rise time of few μs was realized. It is ideally suited to investigate the temporal response of X-ray detectors with response times of the order of μs to ms, in particular, any kind of ionization chambers and large area photo diodes. The drive mechanism consists of a brushless DC motor and driver electronics from a common hard disk drive, keeping the cost at an absolute minimum. Due to its simple construction and small dimensions, this chopper operates at home lab based X-ray tubes and synchrotron radiation sources as well. The dynamics of the most important detectors used in time resolved X-ray absorption spectroscopy, namely, ionization chambers and Passivated Implanted Planar Silicon photodiodes, were investigated in detail. The results emphasize the applicability of this X-ray chopper.

  16. Hard disk drive based microsecond x-ray chopper for characterization of ionization chambers and photodiodes

    Energy Technology Data Exchange (ETDEWEB)

    Müller, O., E-mail: o.mueller@uni-wuppertal.de; Lützenkirchen-Hecht, D.; Frahm, R. [Bergische Universität Wuppertal, Gaußstraße 20, Wuppertal 42119 (Germany)

    2015-03-15

    A fast X-ray chopper capable of producing ms long X-ray pulses with a typical rise time of few μs was realized. It is ideally suited to investigate the temporal response of X-ray detectors with response times of the order of μs to ms, in particular, any kind of ionization chambers and large area photo diodes. The drive mechanism consists of a brushless DC motor and driver electronics from a common hard disk drive, keeping the cost at an absolute minimum. Due to its simple construction and small dimensions, this chopper operates at home lab based X-ray tubes and synchrotron radiation sources as well. The dynamics of the most important detectors used in time resolved X-ray absorption spectroscopy, namely, ionization chambers and Passivated Implanted Planar Silicon photodiodes, were investigated in detail. The results emphasize the applicability of this X-ray chopper.

  17. Hard X-Ray PHA System on the HT-7 Tokamak

    Science.gov (United States)

    Lin, Shiyao; Shi, Yuejiang; Wan, Baonian; Chen, Zhongyong; Hu, Liqun

    2006-05-01

    A new hard X-ray pulse-height analysis (PHA) system has been established on HT-7 tokamak for long pulse steady-state operation. This PHA system consists of hard X-ray diagnostics and multi-channel analysers (MCA). The hard X-ray diagnostics consists of a vertical X-ray detector array (CdTe) and a horizontal X-ray detector array (NaI). The hard X-ray diagnostics can provide the profile of power deposition and the distribution function of fast electron during radio frequency (RF) current drive. The MCA system is the electronic part of the PHA system, which has been modularized and linked to PC through LAN. Each module of MCA can connect with 8 X-ray detectors. The embedded Ethernet adapter in the MCA module makes the data communication between PC and MCA very convenient. A computer can control several modules of MCA through certain software and a hub. The RAM in MCA can store 1024 or more spectra for each detector and therefore the PHA system can be applied in the long pulse discharge of several minutes.

  18. HIgh Rate X-ray Fluorescence Detector

    Energy Technology Data Exchange (ETDEWEB)

    Grudberg, Peter Matthew [XIA LLC

    2013-04-30

    The purpose of this project was to develop a compact, modular multi-channel x-ray detector with integrated electronics. This detector, based upon emerging silicon drift detector (SDD) technology, will be capable of high data rate operation superior to the current state of the art offered by high purity germanium (HPGe) detectors, without the need for liquid nitrogen. In addition, by integrating the processing electronics inside the detector housing, the detector performance will be much less affected by the typically noisy electrical environment of a synchrotron hutch, and will also be much more compact than current systems, which can include a detector involving a large LN2 dewar and multiple racks of electronics. The combined detector/processor system is designed to match or exceed the performance and features of currently available detector systems, at a lower cost and with more ease of use due to the small size of the detector. In addition, the detector system is designed to be modular, so a small system might just have one detector module, while a larger system can have many you can start with one detector module, and add more as needs grow and budget allows. The modular nature also serves to simplify repair. In large part, we were successful in achieving our goals. We did develop a very high performance, large area multi-channel SDD detector, packaged with all associated electronics, which is easy to use and requires minimal external support (a simple power supply module and a closed-loop water cooling system). However, we did fall short of some of our stated goals. We had intended to base the detector on modular, large-area detectors from Ketek GmbH in Munich, Germany; however, these were not available in a suitable time frame for this project, so we worked instead with pnDetector GmbH (also located in Munich). They were able to provide a front-end detector module with six 100 m^2 SDD detectors (two monolithic arrays of three elements each) along with

  19. Recent applications of hard x-ray photoelectron spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Weiland, Conan; Woicik, Joseph C., E-mail: Joseph.Woicik@NIST.gov [National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); Rumaiz, Abdul K. [National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, New York 11973 (United States); Pianetta, Piero [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States)

    2016-05-15

    Recent applications of hard x-ray photoelectron spectroscopy (HAXPES) demonstrate its many capabilities in addition to several of its limitations. Examples are given, including measurement of buried interfaces and materials under in situ or in operando conditions, as well as measurements under x-ray standing-wave and resonant excitation. Physical considerations that differentiate HAXPES from photoemission measurements utilizing soft x-ray and ultraviolet photon sources are also presented.

  20. Hard X-ray techniques suitable for polymer experiments

    Energy Technology Data Exchange (ETDEWEB)

    Bras, W; Goossens, H; Goderis, B, E-mail: Wim.Bras@esrf.fr [Netherlands Organisation for Scientific Research (NWO) (Netherlands); DUBBLE-ESRF, BP 220, F38043 Grenoble Cedex (France); Department of Chemical Engineering and Chemistry, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven (Netherlands); Molecular and Nanomaterials, Chemistry Department, Catholic University of Leuven, Celestijnenlaan 200F (Belgium)

    2010-11-15

    Polymers have been studied since 1979 with 8-12 keV synchrotron radiation X-ray scattering methods and the number and sophistication of the experiments have rapidly grown ever since. More recently, new experimental techniques have been developed that use softer or harder X-rays in less conventional ways. This article provides a brief overview of the possibilities of hard X-ray techniques and indicates some areas that might gain from further developments.

  1. Microfabrication of hard x-ray lenses

    DEFF Research Database (Denmark)

    Stöhr, Frederik

    heights and improved uniformity compared to what is currently available. To this end, established fabrication procedures are improved and the toolbox used for lens development is enriched. The central theme of this thesis is x-ray microscopy (XRM). As a spearhead of today’s materials research it provides...... in turn asks for highly precise metrology. Therefore, a mix of techniques including optical profilometry and atomic force microscopy (AFM) has been used to obtain reliable information about the detailed three-dimensional shapes of the lenses. Adequate sample preparation and measuring procedures have been...... of space for sample surroundings and ensure low-divergent and wide x-ray beams with narrow waists. Both results are substantial improvements to what was available at the start of this thesis work. The challenge of making x-ray objectives in silicon by interdigitation of lenslets alternately focusing...

  2. Broad-band hard X-ray reflectors

    DEFF Research Database (Denmark)

    Joensen, K.D.; Gorenstein, P.; Hoghoj, P.

    1997-01-01

    of the multilayer is found to agree extraordinarily well with theory (assuming an interface roughness of 4.5 Angstrom), while the agreement for the gold film is less, The overall performance of the supermirror is superior to that of gold, extending the band of reflection at least a factor of 2.8 beyond......Interest in optics for hard X-ray broad-band application is growing. In this paper, we compare the hard X-ray (20-100 keV) reflectivity obtained with an energy-dispersive reflectometer, of a standard commercial gold thin-film with that of a 600 bilayer W/Si X-ray supermirror. The reflectivity...... that of the gold, Various other design options are discussed, and we conclude that continued interest in the X-ray supermirror for broad-band hard X-ray applications is warranted....

  3. Development of Compton X-ray spectrometer for high energy resolution single-shot high-flux hard X-ray spectroscopy.

    Science.gov (United States)

    Kojima, Sadaoki; Ikenouchi, Takahito; Arikawa, Yasunobu; Sakata, Shohei; Zhang, Zhe; Abe, Yuki; Nakai, Mitsuo; Nishimura, Hiroaki; Shiraga, Hiroyuki; Ozaki, Tetsuo; Miyamoto, Shuji; Yamaguchi, Masashi; Takemoto, Akinori; Fujioka, Shinsuke; Azechi, Hiroshi

    2016-04-01

    Hard X-ray spectroscopy is an essential diagnostics used to understand physical processes that take place in high energy density plasmas produced by intense laser-plasma interactions. A bundle of hard X-ray detectors, of which the responses have different energy thresholds, is used as a conventional single-shot spectrometer for high-flux (>10(13) photons/shot) hard X-rays. However, high energy resolution (Δhv/hv spectrometer because its energy resolution is limited by energy differences between the response thresholds. Experimental demonstration of a Compton X-ray spectrometer has already been performed for obtaining higher energy resolution than that of DET spectrometers. In this paper, we describe design details of the Compton X-ray spectrometer, especially dependence of energy resolution and absolute response on photon-electron converter design and its background reduction scheme, and also its application to the laser-plasma interaction experiment. The developed spectrometer was used for spectroscopy of bremsstrahlung X-rays generated by intense laser-plasma interactions using a 200 μm thickness SiO2 converter. The X-ray spectrum obtained with the Compton X-ray spectrometer is consistent with that obtained with a DET X-ray spectrometer, furthermore higher certainly of a spectral intensity is obtained with the Compton X-ray spectrometer than that with the DET X-ray spectrometer in the photon energy range above 5 MeV.

  4. Direct-write X-ray lithography using a hard X-ray Fresnel zone plate.

    Science.gov (United States)

    Lee, Su Yong; Noh, Do Young; Lee, Hae Cheol; Yu, Chung-Jong; Hwu, Yeukuang; Kang, Hyon Chol

    2015-05-01

    Results are reported of direct-write X-ray lithography using a hard X-ray beam focused by a Fresnel zone plate with an outermost zone width of 40 nm. An X-ray beam at 7.5 keV focused to a nano-spot was employed to write arbitrary patterns on a photoresist thin film with a resolution better than 25 nm. The resulting pattern dimension depended significantly on the kind of underlying substrate, which was attributed to the lateral spread of electrons generated during X-ray irradiation. The proximity effect originated from the diffuse scattering near the focus and electron blur was also observed, which led to an increase in pattern dimension. Since focusing hard X-rays to below a 10 nm spot is currently available, the direct-write hard X-ray lithography developed in this work has the potential to be a promising future lithographic method.

  5. Measurements of Si Hybrid CMOS X-Ray Detector Characteristics

    CERN Document Server

    Bongiorno, Stephen D; Burrows, David N; Cook, Robert; Bai, Yibin; Farris, Mark

    2009-01-01

    The development of Hybrid CMOS Detectors (HCDs) for X-Ray telescope focal planes will place them in con- tention with CCDs on future satellite missions due to their faster frame rates, flexible readout scenarios, lower power consumption, and inherent radiation hardness. CCDs have been used with great success on the current generation of X-Ray telescopes (e.g. Chandra, XMM, Suzaku, and Swift). However their bucket-brigade read-out architecture, which transfers charge across the chip with discrete component readout electronics, results in clockrate limited readout speeds that cause pileup (saturation) of bright sources and an inherent susceptibility to radiation induced displacement damage that limits mission lifetime. In contrast, HCDs read pixels with low power, on-chip multiplexer electronics in a random access fashion. Faster frame rates achieved with multi-output readout design will allow the next generation's larger effective area telescopes to observe bright sources free of pileup. Radiation damaged latt...

  6. Adaptive Lobster-Eye Hard X-Ray Telescope Project

    Data.gov (United States)

    National Aeronautics and Space Administration — To address NASA needs for hard X-ray telescopes for starlight detection and wavefront analysis, Physical Optics Corporation (POC) proposes to develop an Adjustable...

  7. Scotch-Tape Mirror for Hard X-rays Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The project is to build a grazing incidence mirror for hard X-rays (E>20 keV) using a “scotch-tape” design, in which a thin plastic tape with a...

  8. Scotch-Tape Mirror for Hard X-rays Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The project is to build a grazing incidence mirror for hard X-rays (E>20 keV) using a “scotch-tape” design, in which a thin plastic tape with a...

  9. Soft X-ray follow-up of five hard X-ray emitters

    CERN Document Server

    Pavan, L; Ferrigno, C; Falanga, M; Campana, S; Paltani, S; Stella, L; Walter, R

    2013-01-01

    We studied the soft-X-ray emission of five hard-X sources: IGR J08262-3736, IGR J17354-3255, IGR J16328-4726, SAX J1818.6-1703 and IGR J17348-2045. These sources are: a confirmed supergiant high mass X-ray binary (IGR J08262-3736); candidates (IGR J17354-3255, IGR J16328- 4726) and confirmed (SAX J1818.6-1703) supergiant fast X-ray transients; IGR J17348-2045 is one of the as-yet unidentified objects discovered with INTEGRAL. Thanks to dedicated XMM-Newton observations, we obtained the first detailed soft X-ray spectral and timing study of IGR J08262-3736. The results obtained from the observations of IGR J17354-3255 and IGR J16328-4726 provided further support in favor of their association with the class of Supergiant Fast X-ray Transients. SAX J1818.6-1703, observed close to phase 0.5, was not detected by XMM-Newton, thus supporting the idea that this source reaches its lowest X-ray luminosity (~10^32 erg/s) around apastron. For IGR J17348-2045 we identified for the first time the soft X-ray counterpart and...

  10. CMOS APS detector characterization for quantitative X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Endrizzi, Marco, E-mail: m.endrizzi@ucl.ac.uk [Dipartimento di Fisica, Università di Siena, Via Roma 56, 53100 Siena (Italy); Istituto Nazionale di Fisica Nucleare INFN, sezione di Pisa, 56127 Pisa (Italy); Oliva, Piernicola [Dipartimento di Chimica e Farmacia, Università di Sassari, via Piandanna 4, 07100 Sassari (Italy); Istituto Nazionale di Fisica Nucleare INFN, Sezione di Cagliari, 09042 Cagliari (Italy); Golosio, Bruno [Sezione di Matematica, Fisica e Ingegneria dell' Informazione, Università di Sassari, via Piandanna 4, 07100 Sassari (Italy); Istituto Nazionale di Fisica Nucleare INFN, Sezione di Cagliari, 09042 Cagliari (Italy); Delogu, Pasquale [Dipartimento di Fisica “E. Fermi”, Università di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Istituto Nazionale di Fisica Nucleare INFN, sezione di Pisa, 56127 Pisa (Italy)

    2013-03-01

    An X-ray Imaging detector based on CMOS Active Pixel Sensor and structured scintillator is characterized for quantitative X-ray imaging in the energy range 11–30 keV. Linearity, dark noise, spatial resolution and flat-field correction are the characteristics of the detector subject of investigation. The detector response, in terms of mean Analog-to-Digital Unit and noise, is modeled as a function of the energy and intensity of the X-rays. The model is directly tested using monochromatic X-ray beams and it is also indirectly validated by means of polychromatic X-ray-tube spectra. Such a characterization is suitable for quantitative X-ray imaging and the model can be used in simulation studies that take into account the actual performance of the detector.

  11. Characterization of new hard X-ray Cataclysmic Variables

    CERN Document Server

    Bernardini, F; Falanga, M; Mukai, K; Matt, G; Bonnet-Bidaud, J -M; Masetti, N; Mouchet, M

    2012-01-01

    We aim at characterizing a sample of 9 new hard X-ray selected Cataclysmic Variable (CVs), to unambiguously identify them as magnetic systems of the Intermediate Polar (IP) type. We performed timing and spectral analysis by using X-ray, and simultaneous UV and optical data collected by XMM-Newton, complemented with hard X-ray data provided by INTEGRAL and Swift. The pulse arrival time were used to estimate the orbital periods. The X-ray spectra were fitted using composite models consisting of different absorbing columns and emission components. Strong X-ray pulses at the White Dwarf (WD) spin period are detected and found to decrease with energy. Most sources are spin-dominated systems in the X-rays, though four are beat dominated at optical wavelengths. We estimated the orbital period in all system (except for IGR J16500-3307), providing the first estimate for IGR J08390-4833, IGR J18308-1232, and IGR J18173-2509. All X-ray spectra are multi-temperature. V2069 Cyg and RX J0636+3535 posses a soft X-ray optica...

  12. Development and characterization of a laser-based hard x-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Tillman, C.

    1996-11-01

    A laser-produced plasma was generated by focusing 100 fs laser pulses, with an energy of 150 mJ, onto metal targets. The laser intensity was expected to reach 10{sup 17} W/cm{sup -2}. Radiation was emitted from the created plasma, with photon energies up to the MeV region. The laser-based X-ray source was optimized, with the purpose of making it a realistic source of hard X-rays (>10 keV). Dedicated equipment was developed for efficient generation and utilization of the hard X-rays. The X-ray source was characterized with respect to its spatial extent and the X-ray yield. Measurements were made of the spectral distribution, by the use of single-photon-counting detectors in different geometries, crystal spectrometers and dose measurements in combination with absorption filters. Ablation of the target material in the laser produced plasma was investigated. Imaging applications have been demonstrated, including ultrafast (picosecond) X-ray imaging, magnification imaging of up to x80, differential imaging in the spectral domain, and imaging of various biological and technical objects. The biological response of ultra-intense X-ray pulses was assessed in cell-culture exposures. The results indicate that the biological response from ultra-intense X-ray exposures is similar to the response with conventional X-ray tubes. 82 refs., 14 figs.

  13. New Detector Development for X-ray Astronomy Project

    Data.gov (United States)

    National Aeronautics and Space Administration — "We propose to continue our detector development program in X-ray astronomy. Under our current grant we are developing a new type of active pixel detector. The...

  14. Hard X-rays and associated weak decimetric bursts

    Science.gov (United States)

    Sawant, H. S.; Lattari, C. J. B.; Benz, A. O.; Dennis, B. R.

    1990-01-01

    Results are presented of observations (made with the Hard X-Ray Burst Spectrometer on the SMM and with the Itapetinga antenna) that unambiguously show associations of hard X-ray bursts with RS-type III bursts between 16:46 UT and 16:52 UT on July 9, 1985. The comparison between the hard X-ray and the radio observations shows a clear association, in at least 13 cases, of the hard X-ray and the decimetric RS bursts. On the average, the X-ray peaks were delayed from the peak of the RS bursts at 1.6 Ghz by about 400 msec. It is shown that, if the time comparisons are made between the peak of the radio pulse and the start of the X-ray burst, the delays are consistent with an electron travel time with a velocity of about 0.3 c from the 800 MHz plasma level to the lower corona, assuming that the radio emission is at the second harmonic.

  15. Attosecond Hard X-ray Free Electron Laser

    Directory of Open Access Journals (Sweden)

    Sandeep Kumar

    2013-03-01

    Full Text Available In this paper, several schemes of soft X-ray and hard X-ray free electron lasers (XFEL and their progress are reviewed. Self-amplified spontaneous emission (SASE schemes, the high gain harmonic generation (HGHG scheme and various enhancement schemes through seeding and beam manipulations are discussed, especially in view of the generation of attosecond X-ray pulses. Our recent work on the generation of attosecond hard X-ray pulses is also discussed. In our study, the enhanced SASE scheme is utilized, using electron beam parameters of an XFEL under construction at Pohang Accelerator Laboratory (PAL. Laser, chicane and electron beam parameters are optimized to generate an isolated attosecond hard X-ray pulse at 0.1 nm (12.4 keV. The simulations show that the manipulation of electron energy beam profile may lead to the generation of an isolated attosecond hard X-ray of 150 attosecond pulse at 0.1 nm.

  16. X-ray imaging detectors for synchrotron and XFEL sources

    OpenAIRE

    Takaki Hatsui; Heinz Graafsma

    2015-01-01

    Current trends for X-ray imaging detectors based on hybrid and monolithic detector technologies are reviewed. Hybrid detectors with photon-counting pixels have proven to be very powerful tools at synchrotrons. Recent developments continue to improve their performance, especially for higher spatial resolution at higher count rates with higher frame rates. Recent developments for X-ray free-electron laser (XFEL) experiments provide high-frame-rate integrating detectors with both high sensitivit...

  17. Hard X-ray Microscopic Imaging Of Human Breast Tissues

    Science.gov (United States)

    Park, Sung H.; Kim, Hong T.; Kim, Jong K.; Jheon, Sang H.; Youn, Hwa S.

    2007-01-01

    X-ray microscopy with synchrotron radiation will be a useful tool for innovation of x-ray imaging in clinical and laboratory settings. It helps us observe detailed internal structure of material samples non-invasively in air. And, it also has the potential to solve some tough problems of conventional breast imaging if it could evaluate various conditions of breast tissue effectively. A new hard x-ray microscope with a spatial resolution better than 100 nm was installed at Pohang Light Source, a third generation synchrotron radiation facility in Pohang, Korea. The x-ray energy was set at 6.95 keV, and the x-ray beam was monochromatized by W/B4C monochromator. Condenser and objective zone plates were used as x-ray lenses. Zernike phase plate next to condenser zone plate was introduced for improved contrast imaging. The image of a sample was magnified 30 times by objective zone plate and 20 times by microscope objective, respectively. After additional 10 times digital magnification, the total magnifying power was up to 6000 times in the end. Phase contrast synchrotron images of 10-μm-thick female breast tissue of the normal, fibroadenoma, fibrocystic change and carcinoma cases were obtained. By phase contrast imaging, hard x-rays enable us to observe many structures of breast tissue without sample preparations such as staining or fixation.

  18. Crystal optics for hard-X-ray spectroscopy of highly charged ions

    OpenAIRE

    Beyer, H. F.; Attia, D.; Banas, D; Bigot, E. -O. Le; Bosch, F.; Dousse, Jean-Claude; Förster, E.; Gumberidze, A.; Hagmann, S.; Heß, S.; J. Hoszowska; Indelicato, P.; Jagodzinski, P.; Kozhuharov, Chr.; Krings, Th.

    2009-01-01

    A twin crystal-spectrometer assembly, operated in the focusing compensated asymmetric Laue geometry has been developed for accurate spectroscopy of fast highly charged heavy ions in the hard-X-ray region. Coupled to the focusing crystal optics is a specially developed two-dimensional position-sensitive X-ray detector which is necessary for retaining spectral resolution also for fast moving sources. We summarize the crystal optics and demonstrate the usefulness of the instrument for spectrosco...

  19. X-ray imaging with the PILATUS 100k detector

    DEFF Research Database (Denmark)

    Bech, Martin; Bunk, O.; David, C.;

    2008-01-01

    We report on the application of the PILATUS 100K pixel detector for medical imaging. Experimental results are presented in the form of X-ray radiographs using standard X-ray absorption contrast and a recently developed phase contrast imaging method. The results obtained with the PILATUS detector...... are compared to results obtained with a conventional X-ray imaging system consisting of an X-ray scintillation screen, lens optics, and a charge coupled device. Finally, the results for both systems are discussed more quantitatively based on an image power spectrum analysis. Udgivelsesdato: April...

  20. X-ray imaging detectors for synchrotron and XFEL sources

    Directory of Open Access Journals (Sweden)

    Takaki Hatsui

    2015-05-01

    Full Text Available Current trends for X-ray imaging detectors based on hybrid and monolithic detector technologies are reviewed. Hybrid detectors with photon-counting pixels have proven to be very powerful tools at synchrotrons. Recent developments continue to improve their performance, especially for higher spatial resolution at higher count rates with higher frame rates. Recent developments for X-ray free-electron laser (XFEL experiments provide high-frame-rate integrating detectors with both high sensitivity and high peak signal. Similar performance improvements are sought in monolithic detectors. The monolithic approach also offers a lower noise floor, which is required for the detection of soft X-ray photons. The link between technology development and detector performance is described briefly in the context of potential future capabilities for X-ray imaging detectors.

  1. X-ray imaging detectors for synchrotron and XFEL sources.

    Science.gov (United States)

    Hatsui, Takaki; Graafsma, Heinz

    2015-05-01

    Current trends for X-ray imaging detectors based on hybrid and monolithic detector technologies are reviewed. Hybrid detectors with photon-counting pixels have proven to be very powerful tools at synchrotrons. Recent developments continue to improve their performance, especially for higher spatial resolution at higher count rates with higher frame rates. Recent developments for X-ray free-electron laser (XFEL) experiments provide high-frame-rate integrating detectors with both high sensitivity and high peak signal. Similar performance improvements are sought in monolithic detectors. The monolithic approach also offers a lower noise floor, which is required for the detection of soft X-ray photons. The link between technology development and detector performance is described briefly in the context of potential future capabilities for X-ray imaging detectors.

  2. Hard X-ray properties of magnetic cataclysmic variables

    CERN Document Server

    Scaringi, S; Norton, A J; Knigge, C; Hill, A B; Clark, D J; Dean, A J; McBride, V A; Barlow, E J; Bassani, L; Bazzano, A; Fiocchi, M; Landi, R

    2009-01-01

    Hard X-ray surveys have proven remarkably efficient in detecting intermediate polars and asynchronous polars, two of the rarest type of cataclysmic variable (CV). Here we present a global study of hard X-ray selected intermediate polars and asynchronous polars, focusing particularly on the link between hard X-ray properties and spin/orbital periods. To this end, we first construct a new sample of these objects by cross-correlating candidate sources detected in INTEGRAL/IBIS observations against catalogues of known CVs. We find 23 cataclysmic variable matches, and also present an additional 9 (of which 3 are definite) likely magnetic cataclysmic variables (mCVs) identified by others through optical follow-ups of IBIS detections. We also include in our analysis hard X-ray observations from Swift/BAT and SUZAKU/HXD in order to make our study more complete. We find that most hard X-ray detected mCVs have P_{spin}/P_{orb}<0.1 above the period gap. In this respect we also point out the very low number of detecte...

  3. The color of X-rays: Spectral X-ray computed tomography using energy sensitive pixel detectors

    NARCIS (Netherlands)

    Schioppa, E.J.

    2014-01-01

    Energy sensitive X-ray imaging detectors are produced by connecting a semiconductor sensor to a spectroscopic pixel readout chip. In this thesis, the applicability of such detectors to X-ray Computed Tomography (CT) is studied. A prototype Medipix based silicon detector is calibrated using X-ray flu

  4. Bragg concentrators for hard (> 10keV) x-ray astronomy: Status report

    DEFF Research Database (Denmark)

    Pareschi, G.; Frontera, F.; Pasqualini, G.

    1997-01-01

    The use of focusing telescopes in hard X-ray (E > 10 keV) astronomy will provide better flux sensitivity and imaging performances with respect to the direct-viewing detectors, utilized until now. We present recent results obtained from our group regarding the possible use of Bragg-diffraction tec......The use of focusing telescopes in hard X-ray (E > 10 keV) astronomy will provide better flux sensitivity and imaging performances with respect to the direct-viewing detectors, utilized until now. We present recent results obtained from our group regarding the possible use of Bragg...

  5. Pulse energy measurement at the hard x-ray laser in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Kato, M.; Tanaka, T.; Saito, N. [National Institute of Advanced Industrial Science and Technology (AIST), NMIJ, Tsukuba 305-8568 (Japan); RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Kurosawa, T. [National Institute of Advanced Industrial Science and Technology (AIST), NMIJ, Tsukuba 305-8568 (Japan); Richter, M. [RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Physikalisch-Technische Bundesanstalt (PTB), Abbestrasse 2-12, D-10587 Berlin (Germany); Sorokin, A. A. [RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Deutsches Elektronen-Synchrotron (DESY), Notkestrasse 85, D-22603 Hamburg (Germany); Ioffe Physico-Technical Institute, RAS, Polytekhnicheskaya 26, 194021 St. Petersburg (Russian Federation); Tiedtke, K. [RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Deutsches Elektronen-Synchrotron (DESY), Notkestrasse 85, D-22603 Hamburg (Germany); Kudo, T.; Yabashi, M. [RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Tono, K. [Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Ishikawa, T. [RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan)

    2012-07-09

    The pulse energies of a free electron laser have accurately been measured in the hard x-ray spectral range. In the photon energy regime from 4.4 keV to 16.8 keV, pulse energies up to 100 {mu}J were obtained at the hard x-ray laser facility SACLA (SPring-8 Angstrom Compact free-electron LAser). Two independent methods, using a cryogenic radiometer and a gas monitor detector, were applied and agreement within 3.3% was achieved. Based on our validated pulse energy measurement, a SACLA online monitor detector could be calibrated for all future experiments.

  6. Optomechanical design of a high-precision detector robot arm system for x-ray nano-diffraction with x-ray nanoprobe

    Science.gov (United States)

    Shu, D.; Kalbfleisch, S.; Kearney, S.; Anton, J.; Chu, Y. S.

    2014-03-01

    Collaboration between Argonne National Laboratory and Brookhaven National Laboratory has created a design for the high-precision detector robot arm system that will be used in the x-ray nano-diffraction experimental station at the Hard X-ray Nanoprobe (HXN) beamline for the NSLS-II project. The robot arm system is designed for positioning and manipulating an x-ray detector in three-dimensional space for nano-diffraction data acquisition with the HXN x-ray microscope. It consists of the following major component groups: a granite base with air-bearing support, a 2-D horizontal base stage, a vertical axis goniometer, a 2-D vertical plane robot arm, a 3-D fast scanning stages group, and a 2-D x-ray pixel detector. The design specifications and unique optomechanical structure of this novel high-precision detector robot arm system will be presented in this paper.

  7. MeV X-ray imaging using plastic scintillating fiber area detectors: a simulation study.

    Science.gov (United States)

    Tang, Shi-Biao; Ma, Qingli; Yin, Zejie; Zhu, Daming

    2008-02-01

    Due to their low cost, flexibility, and convenience for long distance data transfer, plastic scintillating fibers (PSFs) have been increasingly used in building detectors or sensors for detecting various radiations and imaging. In this work, the possibility of using PSF coupled with charge-coupled devices (CCD) to build area detectors for X-ray imaging is studied using a Monte Carlo simulation. The focus is on X-ray imaging with energy from a few 100 keV to about 20 MeV. It is found that the efficiency of PSF in detecting X-ray in this energy range is low. The performance can be improved by coating a PSF with X-ray absorption layers and the MTF of the system is presented. It seems possible to build such area detectors with PSFs for imaging hard X-rays under certain environment.

  8. X-ray Properties of an Unbiased Hard X-ray Detected Sample of AGN

    Science.gov (United States)

    Winter, Lisa M.; Mushotzky, Richard F.; Tueller, Jack; Markwardt, Craig

    2007-01-01

    The SWIFT gamma ray observatory's Burst Alert Telescope (BAT) has detected a sample of active galactic nuclei (AGN) based solely on their hard X-ray flux (14-195keV). In this paper, we present for the first time XMM-Newton X-ray spectra for 22 BAT AGXs with no previously analyzed X-ray spectra. If our sources are a representative sample of the BAT AGN, as we claim, our results present for the first time global X-ray properties of an unbiased towards absorption (n(sub H) = 0.03), AGN sample. We find 9/22 low absorption (n(sub H) 2.0 keV. Five of the complex sources (NGC 612, ESO 362-G018, MRK 417, ESO 506-G027, and NGC 6860) are classified as Compton-thick candidates. Further, we find four more sources (SWIFT J0641.3+3257, SWIFT J0911.2+4533, SWIFT J1200.8+0650, and NGC 4992) with properties consistent with the hidden/buried AGN reported by Ueda et al. (2007). Finally, we include a comparison of the XMM EPIC spectra with available SWIFT X-ray Telescope (XRT) observations. From these comparisons, we find 6/16 sources with varying column densities, 6/16 sources with varying power law indices, and 13/16 sources with varying fluxes, over periods of hours to months. Flux and power law index are correlated for objects where both parameters vary.

  9. BAMline: the first hard X-ray beamline at BESSY II

    Energy Technology Data Exchange (ETDEWEB)

    Goerner, W.; Hentschel, M.P.; Mueller, B.R. E-mail: bernd.mueller@bam.de; Riesemeier, H.; Krumrey, M.; Ulm, G.; Diete, W.; Klein, U.; Frahm, R

    2001-07-21

    The first hard X-ray beamline at BESSY II will be installed by BAM and PTB at a superconducting 7 T wavelength shifter. The main optical elements of the beamline are a Double-Multilayer-Monochromator and a Double-Crystal-Monochromator. The two devices can be used separately or in-line. Main applications of monochromatic radiation with photon energies up to 50 keV are X-ray fluorescence analysis, micro-computed tomography, X-ray topography, detector calibration and reflectometry. Calculable undispersed radiation up to 200 keV will be available for radiometric applications.

  10. Hard x-ray spectroscopy for proton flare prediction

    Science.gov (United States)

    Garcia, Howard A.; Farnik, Frantisek; Kiplinger, Alan L.

    1998-11-01

    High energy interplanetary proton events can jeopardize vital military and civilian spacecraft by disrupting logical circuits and by actually damaging spacecraft electronic components. Studies of solar hard x-rays indicate that high-energy proton events observed near Earth are highly associated with an uncommon type of solar flare exhibiting temporal progressively hardening hard x-ray spectra. A hard x-ray spectrometer is being developed by the Czech Astronomical Institute to provide a test bed for evaluating this phenomenon as a possible proton-storm prediction method. The instrument is designed to measure hard x-ray spectra in a high fluence, high-energy particle background environment such as that found at geosynchronous altitude. This experiment has been selected for space flight by the DoD Space Test Program and will fly aboard the Department of Energy satellite, Multi-spectral thermal Imager, scheduled for a three year mission, beginning in late 1999. The timing of this mission, fortuitously, coincides with the experiment are: 1) to evaluate the efficacy of this type of solar instrument in predicting interplanetary proton storms; 2) to study the high-energy physics of solar flares in concert with the premier flight of the NOAA soft x-ray imaging telescope, SXI, on the GOES 12 weather satellite and other solar mission. If the first goal is demonstrated by this mission, continuous monitoring of the Sun for proton events could become operational from geo-synchronous orbit during solar cycle 24.

  11. INTEGRAL survey of the Cassiopeia region in hard X rays

    CERN Document Server

    Den Hartog, P R; Hermsen, W; Kuiper, L; Vink, J; in 't Zand, J J M

    2006-01-01

    We report on the results of a deep 1.6 Ms INTEGRAL observation of the Cassiopeia region performed from December 2003 to February 2004. Eleven sources were detected with the imager IBIS-ISGRI at energies above 20 keV, including three new hard X-ray sources. Most remarkable is the discovery of hard X-ray emission from the anomalous X-ray pulsar 4U 0142+61, which shows emission up to \\~150 keV with a very hard power-law spectrum with photon index Gamma = 0.73 +/- 0.17. We derived flux upper limits for energies between 0.75 MeV and 30 MeV using archival data from the Compton telescope COMPTEL. In order to reconcile the very hard spectrum of 4U 0142+61 measured by INTEGRAL with the COMPTEL upper limits, the spectrum has to bend or break between ~75 keV and ~750 keV. 1E 2259+586, another anomalous X-ray pulsar in this region, was not detected. INTEGRAL and COMPTEL upper limits are provided. The new INTEGRAL sources are IGR J00370+6122 and IGR J00234+6144. IGR J00370+6122 is a new supergiant X-ray binary with an orb...

  12. Towards hard X-ray imaging at GHz frame rate

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhehui [Los Alamos National Laboratory; Morris, Christopher [Los Alamos National Laboratory; Luo, Shengnian [Los Alamos National Laboratory; Kwiatkowski, Kris K. [Los Alamos National Laboratory; Kapustinsky, Jon S. [Los Alamos National Laboratory

    2012-05-02

    Gigahertz (GHz) imaging using hard X-rays ({approx}> 10 keV) can be useful to high-temperature plasma experiments, as well as research using coherent photons from synchrotron radiation and X-ray free electron lasers. GHz framing rate can be achieved by using multiple cameras through multiplexing. The advantages and trade-offs of single-photon detection mode, when no more than one X-ray photon is detected per pixel, are given. Two possible paths towards X-ray imaging at GHz frame rates using a single camera are (a) Avalanche photodiode arrays of high-Z materials and (b) Microchannel plate photomultipliers in conjunction with materials with large indices of refraction.

  13. Towards hard x-ray imaging at GHz frame rate.

    Science.gov (United States)

    Wang, Zhehui; Morris, C L; Kapustinsky, J S; Kwiatkowski, K; Luo, S-N

    2012-10-01

    Gigahertz (GHz) imaging using hard x-rays (> or approximately equal to 10 keV) can be useful to high-temperature plasma experiments, as well as research and applications using coherent photons from synchrotron radiation and x-ray free electron lasers. GHz framing rate can be achieved by using multiple cameras through multiplexing. The advantages and trade-offs of single-photon detection mode, when no more than one x-ray photon is detected per pixel, are given. Two possible paths towards x-ray imaging at GHz frame rates using a single camera are: (a) avalanche photodiode arrays of high-Z materials and (b) microchannel plate photomultipliers in conjunction with materials with large indices of refraction.

  14. Towards hard X-ray imaging at GHz frame rate

    CERN Document Server

    Wang, Zhehui; Kapustinsky, J S; Kwiatkowski, K; Luo, S -N

    2012-01-01

    Gigahertz (GHz) imaging using hard X-rays ($\\gtrsim$ 10 keV) can be useful to high-temperature plasma experiments, as well as research using coherent photons from synchrotron radiation and X-ray free electron lasers. GHz framing rate can be achieved by using multiple cameras through multiplexing. The advantages and trade-offs of single-photon detection mode, when no more than one X-ray photon is detected per pixel, are given. Two possible paths towards X-ray imaging at GHz frame rates using a single camera are a.) Avalanche photodiode arrays of high-Z materials and b.) Microchannel plate photomultipliers in conjunction with materials with large indices of refraction.

  15. Towards hard x-ray imaging at GHz frame rate

    Energy Technology Data Exchange (ETDEWEB)

    Wang Zhehui; Morris, C. L.; Kapustinsky, J. S.; Kwiatkowski, K.; Luo, S.-N. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States)

    2012-10-15

    Gigahertz (GHz) imaging using hard x-rays ( Greater-Than-Or-Equivalent-To 10 keV) can be useful to high-temperature plasma experiments, as well as research and applications using coherent photons from synchrotron radiation and x-ray free electron lasers. GHz framing rate can be achieved by using multiple cameras through multiplexing. The advantages and trade-offs of single-photon detection mode, when no more than one x-ray photon is detected per pixel, are given. Two possible paths towards x-ray imaging at GHz frame rates using a single camera are: (a) avalanche photodiode arrays of high-Z materials and (b) microchannel plate photomultipliers in conjunction with materials with large indices of refraction.

  16. A hard X-ray laboratory for monochromator characterisation

    Energy Technology Data Exchange (ETDEWEB)

    Hamelin, B. [Institut Max von Laue - Paul Langevin (ILL), 38 - Grenoble (France)

    1997-04-01

    Since their installation at ILL during the 1970`s the ILL {gamma}-ray diffractometers have been intensively used in the development of neutron monochromators. However, the ageing of the sources and new developments in hard X-ray diffractometry lead to a decision at the end of 1995 to replace the existing {gamma}-ray laboratory with a hard X-ray laboratory, based on a 420 keV generator, making available in the long term several beam-lines for rapid characterisation of monochromator crystals. The facility is now installed and its characteristics and advantages are outlined. (author). 2 refs.

  17. eHXI: a permanently installed, hard x-ray imager for the National Ignition Facility

    Science.gov (United States)

    Döppner, T.; Bachmann, B.; Albert, F.; Bell, P.; Burns, S.; Celeste, J.; Chow, R.; Divol, L.; Dewald, E. L.; Hohenberger, M.; Huntington, C. M.; Izumi, N.; LaCaille, G.; Landen, O. L.; Palmer, N.; Park, H.-S.; Thomas, C. A.

    2016-06-01

    We have designed and built a multi-pinhole imaging system for high energy x-rays (>= 50 keV) that is permanently installed in the equatorial plane outside of the target chamber at the National Ignition Facility (NIF). It records absolutely-calibrated, time-integrated x-ray images with the same line-of-sight as the multi-channel, spatially integrating hard x-ray detector FFLEX [McDonald et al., Rev. Sci. Instrum. 75 (2004) 3753], having a side view of indirect-drive inertial confinement fusion (ICF) implosion targets. The equatorial hard x-ray imager (eHXI) has recorded images on the majority of ICF implosion experiments since May 2011. eHXI provides valuable information on hot electron distribution in hohlraum experiments, target alignment, potential hohlraum drive asymmetries and serves as a long term reference for the FFLEX diagnostics.

  18. Filtered fluorescer x-ray detector

    Energy Technology Data Exchange (ETDEWEB)

    Bruns, H.C.; Emig, J.A.; Thoe, R.S.; Springer, P.T.; Hernandez, J.A.

    1995-04-01

    Recently, an instrument capable of measuring x-rays between 8 and 90 keV was conceived to help understand conditions pertaining to pulsed power research. This resulted in the development of a versatile device that would incrementally detect x-rays emitted at predetermined energy bands over this range. To accomplish this, an array of well characterized filter-fluorescer combinations were produced which would allow fluoresced x-rays to be observed by time resolved electro-optical devices. As many as sixteen channels could be utilized with each channel having a corresponding background channel. Upon completion of the device, a three week series of experiments was then successfully carried out.

  19. High-resolution detectors for soft X-ray spectroscopy

    OpenAIRE

    Soman, Matthew

    2014-01-01

    Resonant Inelastic X-ray Scattering (RIXS) is a modern soft X-ray spectroscopy technique used to investigate the structure of and excitations in materials. It requires high resolution spectrometers and a brilliant, tunable, X-ray source and therefore is carried out at spectrometers such as SAXES at the Swiss Light Source Light, a synchrotron at the Paul Scherrer Institut.\\ud \\ud SAXES uses a grating to disperse X-rays scattered from a sample across a position sensitive detector, a Charge-Coup...

  20. Recent developments in hard X-ray tomography

    CERN Document Server

    Rau, C; Snigirev, A; Schrör, C; Tümmler, J; Lengeler, B

    2001-01-01

    A new technique for magnified hard X-ray tomography using compound refractive lenses (CRLs) has been tested. A full-field X-ray microscope was included into a conventional microtomography setup at a synchrotron undulator beamline. Experiments were carried out at 19.7 keV with a monochromatic beam as well as with the so-called 'pink' beam using a larger energy bandwidth. During this pilot experiment a resolution of about 1 mu m was already achieved, which corresponds to the best resolution obtained with phase-contrast enhanced microtomography. The technique has the potential to increase the spatial resolution of hard-X-ray microtomography to a scale of several hundred nanometers.

  1. X-ray Measurements of Black Hole X-ray Binary Source GRS 1915+105 and the Evolution of Hard X-ray Spectrum

    Indian Academy of Sciences (India)

    R. K. Manchanda

    2000-06-01

    We report the spectral measurement of GRS 1915+105 in the hard X-ray energy band of 20-140keV. The observations were made on March 30th, 1997 during a quiescent phase of the source. We discuss the mechanism of emission of hard X-ray photons and the evolution of the spectrum by comparing the data with earlier measurements and an axiomatic model for the X-ray source.

  2. Fourier-transform Ghost Imaging with Hard X-rays

    CERN Document Server

    Yu, Hong; Han, Shensheng; Xie, Honglan; Du, Guohao; Xiao, Tiqiao; Zhu, Daming

    2016-01-01

    Knowledge gained through X-ray crystallography fostered structural determination of materials and greatly facilitated the development of modern science and technology in the past century. Atomic details of sample structures is achievable by X-ray crystallography, however, it is only applied to crystalline structures. Imaging techniques based on X-ray coherent diffraction or zone plates are capable of resolving the internal structure of non-crystalline materials at nanoscales, but it is still a challenge to achieve atomic resolution. Here we demonstrate a novel lensless Fourier-transform ghost imaging method with pseudo-thermal hard X-rays by measuring the second-order intensity correlation function of the light. We show that high resolution Fourier-transform diffraction pattern of a complex structure can be achieved at Fresnel region, and the amplitude and phase distributions of a sample in spatial domain can be retrieved successfully. The method of lensless X-ray Fourier-transform ghost imaging extends X-ray...

  3. Fourier-Transform Ghost Imaging with Hard X Rays

    Science.gov (United States)

    Yu, Hong; Lu, Ronghua; Han, Shensheng; Xie, Honglan; Du, Guohao; Xiao, Tiqiao; Zhu, Daming

    2016-09-01

    Knowledge gained through x-ray crystallography fostered structural determination of materials and greatly facilitated the development of modern science and technology in the past century. However, it is only applied to crystalline structures and cannot resolve noncrystalline materials. Here we demonstrate a novel lensless Fourier-transform ghost imaging method with pseudothermal hard x rays that extends x-ray crystallography to noncrystalline samples. By measuring the second-order intensity correlation function of the light, Fourier-transform diffraction pattern of a complex amplitude sample is achieved at the Fresnel region in our experiment and the amplitude and phase distributions of the sample in the spatial domain are retrieved successfully. For the first time, ghost imaging is experimentally realized with x rays. Since a highly coherent x-ray source is not required, the method can be implemented with laboratory x-ray sources and it also provides a potential solution for lensless diffraction imaging with fermions, such as neutrons and electrons where intensive coherent sources usually are not available.

  4. Crab Nebula Variations in Hard X-rays

    Science.gov (United States)

    Wilson-Hodge, Colleen A.

    2012-01-01

    The Crab Nebula was surprisingly variable from 2001-2010, with less variability before 2001 and since mid-2010. We presented evidence for spectral softening from RXTE, Swift/BAT, and Fermi GBM during the mid-2008-2010 flux decline. We see no clear connections between the hard X-ray variations and the GeV flares

  5. Solar hard X-rays and gamma-rays

    Institute of Scientific and Technical Information of China (English)

    甘为群; 常进; 李友平; 林春梅

    2002-01-01

    We briefly introduce our recent work on the spectral evolution of energetic protons, the beam property of accelerated electrons, the gamma-ray flare classification, the temporal features of the annihilation line, the hard X-ray delayed events, the hydrodynamic process, and the continuum emission in solar flares.

  6. Dark Matter Detection with Hard X-ray Telescopes

    CERN Document Server

    Jeltema, Tesla E

    2011-01-01

    We analyze the impact of future hard X-ray observations on the search for indirect signatures of particle dark matter in large extragalactic systems such as nearby clusters or groups of galaxies. We argue that the hard X-ray energy band falls squarely at the peak of the inverse Compton emission from electrons and positrons produced by dark matter annihilation or decay for a large class of dark matter models. Specifically, the most promising are low-mass models with a hard electron-positron annihilation final state spectrum and intermediate-mass models with a soft electron-positron spectrum. We find that constraints on dark matter models similar to the current constraints from the Fermi Gamma-Ray Space Telescope will be close to the limit of the sensitivity of the near-term hard X-ray telescopes NuSTAR and ASTRO-H for relatively long observations, but an instrument similar to the Wide Field Imager proposed for the International X-ray Observatory would allow significant gains to be made. In the future, the abil...

  7. Bragg concentrators for hard (> 10keV) x-ray astronomy: Status report

    DEFF Research Database (Denmark)

    Pareschi, G.; Frontera, F.; Pasqualini, G.

    1997-01-01

    The use of focusing telescopes in hard X-ray (E > 10 keV) astronomy will provide better flux sensitivity and imaging performances with respect to the direct-viewing detectors, utilized until now. We present recent results obtained from our group regarding the possible use of Bragg-diffraction tec...

  8. Development of a CZT spectroscopic 3D imager prototype for hard X ray astronomy

    DEFF Research Database (Denmark)

    Auricchio, N.; Caroli, E.; Basili, A.

    2013-01-01

    The development of focusing optics based on wide band Laue lenses operating from ∼60 keV up to several hundreds of keV is particularly challenging. This type of hard X-ray or gamma ray optics requires a high performance focal plane detector in order to exploit to the best its intrinsic capabiliti...

  9. HXMT satellite for space hard X-ray observation

    Science.gov (United States)

    Wu, Y.; Ren, D.; You, Z.

    Space hard X-ray in the energy band from 10Kev to 250KeV is very important to the research of high energy astrophysical processes, especially some of the fundamental problems in astrophysics. Due to imaging difficulty in the hard X-ray band, Observations made over this band is comparatively less than other bands such as soft X-ray and gamma -ray. Up to now, there has been no hard X ray all sky- survey of high sensitivity. Based on the Direct Demodulation imaging method recently developed, the Hard X- ray Modulation Telescope(HXMT) mission is proposed under the Major State Basic Research Development Program of China. The scientific objective of HXMT mission is to realize the first hard X-ray all sky survey of high sensitivy and angular resolution in the world, and to present the first detailed sky map of hard X r a y - distribution. In this article, the physical basis, the imaging principle and the basic structure of HXMT are briefly introduced. The expected angular resolution of observation and position accuracy of radiant source are 2' and 0.2' respectively. Based on the analysis of the mission requirement of HXMT, the mission design of HXMT satellite is presented in which the concept of integrative design approach is presented and implemented. The design of spacecraft subsystems such as strcuture,C&DH and energy are also introduced. To meet the high precision demand of the attitude determination of HXMT, a new Attitude Determination &Control Subsystem(ADCS) scheme is presented in which the Microminiature Inertial Measurement Unit(MIMU) is employed as one of the key attitude sensors. Combined with star tracker, the expected attitude measurement accuracy is 0.01° in the normal mission mode. Based on all these thoughts, the ADCS is analyzed and its general design is presented in the paper. As the first chinese space hard X-ray observatory, the design approach of HXMT satellite is also helpful for other space exploration missions such as solar activity inspection

  10. Characterization of New Hard X-ray Cataclysmic Variables

    Science.gov (United States)

    Bernardini, F.; deMartino, D.; Falanga, M.; Mukai, K.; Matt, G.; Bonnet-Bidaud, J.-M.; Masetti, N.; Mouchet, M.

    2012-01-01

    Aims. We aim at characterizing a sample of nine new hard X-ray selected Cataclysmic Variable (CVs), to unambiguously identify them as magnetic systems of the Intermediate Polar (IP) type. Methods. We performed detailed timing and spectral analysis by using X-ray, and simultaneous UV and optical data collected by XMM-Newton, complemented with hard X-ray data provided by INTEGRAL and Swift. The pulse arrival time were used to estimate the orbital periods. The broad band X-ray spectra were fitted using composite models consisting of different absorbing columns and emission components. Results. Strong X-ray pulses at the White Dwarf (WD) spin period are detected and found to decrease with energy. Most sources are spin-dominated systems in the X-rays, though four are beat dominated at optical wavelengths. We estimated the orbital period in all system (except for IGR J16500-3307), providing the first estimate for IGRJ08390-4833, IGRJ18308-1232, and IGR J18173-2509. All X-ray spectra are multi-temperature. V2069 Cyg and RX J0636+3535 poses a soft X-ray optically thick component at kT approx. 80 eV. An intense K (sub alpha) Fe line at 6.4 keV is detected in all sources. An absorption edge at 0.76 keV from OVII is detected in IGR J08390-4833. The WD masses and lower limits to the accretion rates are also estimated. Conclusions. We found all sources to be IPs. IGR J08390-4833, V2069 Cyg, and IGR J16500-3307 are pure disc accretors, while IGR J18308-1232, IGR J1509-6649, IGR J17195-4100, and RX J0636+3535 display a disc-overflow accretion mode. All sources show a temperature gradient in the post-shock regions and a highly absorbed emission from material located in the pre-shock flow which is also responsible for the X-ray pulsations. Reflection at the WD surface is likely the origin of the fluorescent iron line. There is an increasing evidence for the presence of a warm absorber in IPs, a feature that needs future exploration. The addition of two systems to the subgroup of

  11. Suzaku observations of the hard X-ray spectrum of Vela Jr

    CERN Document Server

    Takeda, Sawako; Terada, Yukikatsu; Tashiro, Makoto S; Katsuda, Satoru; Yamazaki, Ryo; Ohira, Yutaka; Iwakiri, Wataru

    2016-01-01

    We report the results of Suzaku observations of the young supernova remnant, Vela Jr.\\ (RX J0852.0$-$4622), which is known to emit synchrotron X-rays, as well as TeV gamma-rays. Utilizing 39 Suzaku mapping observation data from Vela Jr., a significant hard X-ray emission is detected with the hard X-ray detector (HXD) from the north-west TeV-emitting region. The X-ray spectrum is well reproduced by a single power-law model with the photon index of 3.15$^{+1.18}_{-1.14}$ in the 12--22 keV band. Compiling this with the soft X-ray spectrum simultaneously observed with the X-ray imaging spectrometer (XIS) onboard Suzaku, we find that the wide-band X-ray spectrum in the 2--22 keV band is reproduced with a single power-law or concave broken power-law model, which are statistically consistent with each other. Whichever the model of a single or broken power-law is appropriate, clearly the spectrum has no rolloff structure. Applying this result to the method introduced in \\citet{yama2014}, we find that one-zone synchro...

  12. Cascaded-systems analysis of sandwich x-ray detectors

    Science.gov (United States)

    Kim, D. W.; Kim, J.; Yun, S.; Youn, H.; Kim, H. K.

    2016-12-01

    Active sandwich-like multilayer detectors have been developed, and their potential for motion-artifact-free dual-energy x-ray imaging at a single exposure has been demonstrated in the material decomposition context. Since the sandwich detector uses the x-ray beam transmittance through the front layer, direct x-ray interaction within photodiodes in the front layer is unavoidable, and which can increase noise in the front detector images. Similar direct x-ray interaction can also occur in the rear detector layer. To obtain a better contrast performance, an additional filter layer can be placed between the two detector layers. However, this filter layer can increase adversely noise in images obtained from the rear detector layer by reducing the number of x-ray photons reaching it. A theoretical model, which can describe the signal-to-noise performance of the sandwich detector as functions of various design parameters, has been developed by using a linear cascaded-systems theory. From the cascaded-systems analysis, the direct x-ray interaction increases noise at the high spatial frequencies where the number of secondary quanta lessens. The intermediate filter layer enhances the contribution of additive electronic noise in the overall noise performance of the rear detector layer. The detailed cascaded-systems analysis on the x-ray sandwich detectors are reported in comparisons with the measured noise-power spectra and detective quantum efficiencies. The developed model will be useful for a better design and practical use of a sandwich detector for single-shot dual-energy imaging.

  13. The High Energy X-ray Imager Technology (HEXITEC) for Solar Hard X-ray Observations

    Science.gov (United States)

    Christe, Steven; Shih, Albert Y.; Gaskin, Jessica; Wilson-Hodge, Colleen; Seller, Paul; Wilson, Matthew

    2015-04-01

    High angular resolution HXR optics require detectors with a large number of fine pixels in order to adequately sample the telescope point spread function (PSF) over the entire field of view. Excessively over-sampling the PSF will increase readout noise and require more processing with no appreciable increase in image quality. An appropriate level of over-sampling is to have 3 pixels within the HPD. For current high resolution X-ray mirrors, the HPD is about 25 arcsec. Over a 6-m focal length this converts to 750 µm, the optimum pixel size is around 250 µm. Annother requirement are that the detectors must also have high efficiency in the HXR region, good energy resolution, low background, low power requirements, and low sensitivity to radiation damage. For solar observations, the ability to handle high counting rates is also extremely desirable. The Rutherford Appleton Laboratory (RAL) in the UK has been developing the electronics for such a detector. Dubbed HEXITEC, for High Energy X-Ray Imaging Technology, this Application Specific Integrated Circuit (ASIC), can be bonded to 1- or 2- mm-thick Cadmium Telluride (CdTe) or Cadmium-Zinc-Telluride (CZT), to create a fine (250 µm pitch) HXR detector. The NASA Marshall Space Flight CenterMSFC and the Goddard Space Flight Center (GSFC) has been working with RAL over the past few years to develop these detectors to be used with HXR focusing telescopes. We present on recent results and capabilities as applied to solar observations.

  14. Complete Hard X-Ray Surveys, AGN Luminosity Functions and the X-Ray Background

    Science.gov (United States)

    Tueller, Jack

    2011-01-01

    AGN are believed to make up most of the Cosmic X-Ray Background (CXB) above a few keV, but this background cannot be fully resolved at energies less than 10 keV due to absorption. The Swift/BAT and INTEGRAL missions are performing the first complete hard x-ray surveys with minimal bias due to absorption. The most recent results for both missions will be presented. Although the fraction of the CXB resolved by these surveys is small, it is possible to derive unbiased number counts and luminosity functions for AGN in the local universe. The survey energy range from 15-150 keV contains the important reflection and cutoff spectral features dominate the shape of the AGN contribution to the CXB. Average spectral characteristics of survey detected AGN will be presented and compared with model distributions. The numbers of hard x-ray blazars detected in these surveys are finally sufficient to estimate this important component's contribution the cosmic background. Constraints on CXB models and their significance will be discussed.

  15. Hard X-ray Characteristics of Anomalous X-ray Pulsars: Results from RXTE and INTEGRAL

    Science.gov (United States)

    den Hartog, Peter R.

    Until recently anomalous X-ray pulsars (AXPs) were known as soft X-ray emitters. This has changed drastically since the discovery of hard X-ray emission (>10 keV) from several AXPs by INTEGRAL (Molkov et al. 2004, Revnivtsev et al. 2004 and den Hartog et al. 2004). Kuiper et al. (2004) discovered pulsed emission in the same energy range using RXTE (PCA and HEXTE) data. Currently four AXPs (1RXS J170849.0-400910, 1E 1841-045, 4U 0142+614 and 1E 2259+586) have been detected, some of them showing emission up to 200 keV. The spectra exhibit extremely hard power laws with photon indices < 1.0 and with apparent luminosities 2-3 orders of magnitude above the rotational energy loss. The origin of this behaviour is not yet understood. An overview containing the current observational status in the temporal and the spectral domains as well as future prospects of AXPs at high energies is presented.

  16. Applications of Hard X-ray Full-Field Transmission X-ray Microscopy at SSRL

    Science.gov (United States)

    Liu, Y.; Andrews, J. C.; Meirer, F.; Mehta, A.; Gil, S. Carrasco; Sciau, P.; Mester, Z.; Pianetta, P.

    2011-09-01

    State-of-the-art hard x-ray full-field transmission x-ray microscopy (TXM) at beamline 6-2C of Stanford Synchrotron Radiation Lightsource has been applied to various research fields including biological, environmental, and material studies. With the capability of imaging a 32-micron field-of-view at 30-nm resolution using both absorption mode and Zernike phase contrast, the 3D morphology of yeast cells grown in gold-rich media was investigated. Quantitative evaluation of the absorption coefficient was performed for mercury nanoparticles in alfalfa roots exposed to mercury. Combining XANES and TXM, we also performed XANES-imaging on an ancient pottery sample from the Roman pottery workshop at LaGraufesenque (Aveyron).

  17. A hard X-ray polarimeter utilizing Compton scattering

    Science.gov (United States)

    Sakurai, H.; Noma, M.; Niizeki, H.

    1991-01-01

    The paper describes a 50-cm-diam prototype of a novel Compton-scattering-type polarimeter for hard X-rays in the energy range 30-100 keV. The characteristics of the prototype polarimeter were investigated for various conditions. It was found that, with polarized X-rays from a simple polarizer, the detection efficiency and the modulation factor of the polarimeter with a 40-mm thick scatterer were 3.2 percent and 0.57 percent, respectively, at about 60 keV.

  18. Hard X-ray Observations of Magnetic Cataclysmic Variables

    CERN Document Server

    Singh, K P; Mukerjee, K; Barrett, P; Schlegel, E M

    2003-01-01

    Hard X-ray light curves and spectral parameters from our analysis of X-ray data of five AM Her type systems - V2301 Oph, V1432 Aql, EP Draconis, GG Leonis, V834 Cen, and one intermediate polar - TV Col, observed using the Rossi X-ray Timing Explorer satellite are presented. A new improved ephemeris has been derived for V2301 Oph using the mid-eclipse timings. Average intensity variations, without any change of shape of the light curve or hardness ratio, are observed on timescales of a few days to a few months in V2301 Oph. V1432 Aql shows erratic variations on a timescale of a day, at least 2 sharp dips near orbital phases 0.35 and 0.5, and a total eclipse. Hard X-ray eclipses are also reported in EP Dra and GG Leo. V834 Cen shows intensity variations on yearly timescale and is found to be in a low state in 2002. In TV Col, a binary orbital modulation at 5.5h, in addition to the spin period of 1910s, is reported for the first time. Maximum spectral temperatures in Polars have been determined and used to estim...

  19. Performance of detectors for x-ray crystallography

    Science.gov (United States)

    Stanton, Martin J.; Phillips, Walter C.

    1993-12-01

    The performance of a detector can be characterized by its efficiency for measuring individual x-rays or for measuring Bragg peak intensities. The performance for detecting individual x- rays or for measuring Bragg peak intensities. The performance for detecting individual x-rays is well modeled by the DQE. The performance for measuring Bragg peak intensities in the presence of an x-ray background can be modeled by an expanded definition of the DQE which allows inclusion of experimental constraints, the XDCE. These constraints include the observation that by increasing the crystal-to-detector distance and using a larger detector, Bragg peaks can be better resolved and the x-ray background reduced. Calculation of the XDCE for a detector consisting of a fiberoptic taper with a phosphor x-ray convertor deposited on the large end and a CCD bonded to the small end demonstrate the need to make the detector area relatively large, possibly at the expense of a decrease in the DQE.

  20. X-ray and gamma ray astronomy detectors

    Science.gov (United States)

    Decher, Rudolf; Ramsey, Brian D.; Austin, Robert

    1994-01-01

    X-ray and gamma ray astronomy was made possible by the advent of space flight. Discovery and early observations of celestial x-rays and gamma rays, dating back almost 40 years, were first done with high altitude rockets, followed by Earth-orbiting satellites> once it became possible to carry detectors above the Earth's atmosphere, a new view of the universe in the high-energy part of the electromagnetic spectrum evolved. Many of the detector concepts used for x-ray and gamma ray astronomy were derived from radiation measuring instruments used in atomic physics, nuclear physics, and other fields. However, these instruments, when used in x-ray and gamma ray astronomy, have to meet unique and demanding requirements related to their operation in space and the need to detect and measure extremely weak radiation fluxes from celestial x-ray and gamma ray sources. Their design for x-ray and gamma ray astronomy has, therefore, become a rather specialized and rapidly advancing field in which improved sensitivity, higher energy and spatial resolution, wider spectral coverage, and enhanced imaging capabilities are all sought. This text is intended as an introduction to x-ray and gamma ray astronomy instruments. It provides an overview of detector design and technology and is aimed at scientists, engineers, and technical personnel and managers associated with this field. The discussion is limited to basic principles and design concepts and provides examples of applications in past, present, and future space flight missions.

  1. Hard X-ray Sources for the Mexican Synchrotron Project

    Science.gov (United States)

    Reyes-Herrera, Juan

    2016-10-01

    One of the principal tasks for the design of the Mexican synchrotron was to define the storage ring energy. The main criteria for choosing the energy come from studying the electromagnetic spectrum that can be obtained from the synchrotron, because the energy range of the spectrum that can be obtained will determine the applications available to the users of the future light source. Since there is a public demand of hard X-rays for the experiments in the synchrotron community users from Mexico, in this work we studied the emission spectra from some hard X-ray sources which could be the best options for the parameters of the present Mexican synchrotron design. The calculations of the flux and the brightness for one Bending Magnet and four Insertion Devices are presented; specifically, for a Superconducting Bending Magnet (SBM), a Superconducting Wiggler (SCW), an In Vacuum Short Period Undulator (IV-SPU), a Superconducting Undulator (SCU) and for a Cryogenic Permanent Magnet Undulator (CPMU). Two commonly available synchrotron radiation programs were used for the computation (XOP and SRW). From the results, it can be concluded that the particle beam energy from the current design is enough to have one or more sources of hard X-rays. Furthermore, a wide range of hard X-ray region can be covered by the analyzed sources, and the choice of each type should be based on the specific characteristics of the X-ray beam to perform the experiments at the involved beamline. This work was done within the project Fomix Conacyt-Morelos ”Plan Estrategico para la construccion y operación de un Sincrotron en Morelos” (224392).

  2. Submicron hard X-ray fluorescence imaging of synthetic elements

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Mark P., E-mail: mjensen@anl.gov [Chemical Sciences and Engineering Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Aryal, Baikuntha P. [Chemical Sciences and Engineering Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Department of Chemistry, University of Chicago, Chicago, IL 60637 (United States); Gorman-Lewis, Drew [Chemical Sciences and Engineering Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Paunesku, Tatjana [Department of Radiation Oncology, Feinberg School of Medicine, Northwestern University, Chicago, IL 60611 (United States); Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL 60611 (United States); Lai, Barry; Vogt, Stefan [X-ray Science Division, Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States); Woloschak, Gayle E. [Department of Radiation Oncology, Feinberg School of Medicine, Northwestern University, Chicago, IL 60611 (United States); Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL 60611 (United States)

    2012-04-13

    Highlights: Black-Right-Pointing-Pointer Actinide elements are mapped with L-edge X-rays and better than 400 nm resolution. Black-Right-Pointing-Pointer A typical detection limit was 2.9 Multiplication-Sign 10{sup -20} moles Pu {mu}m{sup -2}. Black-Right-Pointing-Pointer XANES measurements provide chemical information in 0.1 {mu}m{sup 2} spots. Black-Right-Pointing-Pointer Selection of materials for encapsulation is important for avoiding interferences. - Abstract: Synchrotron-based X-ray fluorescence microscopy (XFM) using hard X-rays focused into sub-micron spots is a powerful technique for elemental quantification and mapping, as well as microspectroscopic measurements such as {mu}-XANES (X-ray absorption near edge structure). We have used XFM to image and simultaneously quantify the transuranic element plutonium at the L{sub 3} or L{sub 2}-edge as well as Th and lighter biologically essential elements in individual rat pheochromocytoma (PC12) cells after exposure to the long-lived plutonium isotope {sup 242}Pu. Elemental maps demonstrate that plutonium localizes principally in the cytoplasm of the cells and avoids the cell nucleus, which is marked by the highest concentrations of phosphorus and zinc, under the conditions of our experiments. The minimum detection limit under typical acquisition conditions with an incident X-ray energy of 18 keV for an average 202 {mu}m{sup 2} cell is 1.4 fg Pu or 2.9 Multiplication-Sign 10{sup -20} moles Pu {mu}m{sup -2}, which is similar to the detection limit of K-edge XFM of transition metals at 10 keV. Copper electron microscopy grids were used to avoid interference from gold X-ray emissions, but traces of strontium present in naturally occurring calcium can still interfere with plutonium detection using its L{sub {alpha}} X-ray emission.

  3. X-ray sensitivity measurements on CVD diamond film detectors

    Energy Technology Data Exchange (ETDEWEB)

    Foulon, F.; Pochet, T. [CEA Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. d`Electronique et d`Instrumentation Nucleaire; Gheeraert, E. [Centre National de la Recherche Scientifique (CNRS), 38 - Grenoble (France)

    1993-12-31

    Microwave chemical vapor deposited (CVD) diamond films have been used to fabricate radiation detectors. The polycrystalline diamond films have a resistivity of 10{sup 12} ohm.cm and carrier mobility and lifetime of about 280 cm{sup 2}/V.s and 530 ps. The detector response to laser pulses (355, 532 and 1064 nm), X-ray flux (15-50 keV) and alpha particles ({sup 241}Am, 5.49 MeV) has been investigated. The response speed of the detector is in the 100 ps range. A sensitivity of about 3 x 10{sup -10} A/V.Gy.s was measured under 50 keV X-ray flux. The detector current response to X-ray flux is almost linear. It is also shown that CVD diamond detectors can be used for alpha particle counting. (authors). 9 figs., 25 refs.

  4. Method and apparatus for micromachining using hard X-rays

    Science.gov (United States)

    Siddons, David Peter; Johnson, Erik D.; Guckel, Henry; Klein, Jonathan L.

    1997-10-21

    An X-ray source such as a synchrotron which provides a significant spectral content of hard X-rays is used to expose relatively thick photoresist such that the portions of the photoresist at an exit surface receive at least a threshold dose sufficient to render the photoresist susceptible to a developer, while the entrance surface of the photoresist receives an exposure which does not exceed a power limit at which destructive disruption of the photoresist would occur. The X-ray beam is spectrally shaped to substantially eliminate lower energy photons while allowing a substantial flux of higher energy photons to pass through to the photoresist target. Filters and the substrate of the X-ray mask may be used to spectrally shape the X-ray beam. Machining of photoresists such as polymethylmethacrylate to micron tolerances may be obtained to depths of several centimeters, and multiple targets may be exposed simultaneously. The photoresist target may be rotated and/or translated in the beam to form solids of rotation and other complex three-dimensional structures.

  5. Accurate determination of segmented X-ray detector geometry.

    Science.gov (United States)

    Yefanov, Oleksandr; Mariani, Valerio; Gati, Cornelius; White, Thomas A; Chapman, Henry N; Barty, Anton

    2015-11-02

    Recent advances in X-ray detector technology have resulted in the introduction of segmented detectors composed of many small detector modules tiled together to cover a large detection area. Due to mechanical tolerances and the desire to be able to change the module layout to suit the needs of different experiments, the pixels on each module might not align perfectly on a regular grid. Several detectors are designed to permit detector sub-regions (or modules) to be moved relative to each other for different experiments. Accurate determination of the location of detector elements relative to the beam-sample interaction point is critical for many types of experiment, including X-ray crystallography, coherent diffractive imaging (CDI), small angle X-ray scattering (SAXS) and spectroscopy. For detectors with moveable modules, the relative positions of pixels are no longer fixed, necessitating the development of a simple procedure to calibrate detector geometry after reconfiguration. We describe a simple and robust method for determining the geometry of segmented X-ray detectors using measurements obtained by serial crystallography. By comparing the location of observed Bragg peaks to the spot locations predicted from the crystal indexing procedure, the position, rotation and distance of each module relative to the interaction region can be refined. We show that the refined detector geometry greatly improves the results of experiments.

  6. Accurate determination of segmented X-ray detector geometry

    Science.gov (United States)

    Yefanov, Oleksandr; Mariani, Valerio; Gati, Cornelius; White, Thomas A.; Chapman, Henry N.; Barty, Anton

    2015-01-01

    Recent advances in X-ray detector technology have resulted in the introduction of segmented detectors composed of many small detector modules tiled together to cover a large detection area. Due to mechanical tolerances and the desire to be able to change the module layout to suit the needs of different experiments, the pixels on each module might not align perfectly on a regular grid. Several detectors are designed to permit detector sub-regions (or modules) to be moved relative to each other for different experiments. Accurate determination of the location of detector elements relative to the beam-sample interaction point is critical for many types of experiment, including X-ray crystallography, coherent diffractive imaging (CDI), small angle X-ray scattering (SAXS) and spectroscopy. For detectors with moveable modules, the relative positions of pixels are no longer fixed, necessitating the development of a simple procedure to calibrate detector geometry after reconfiguration. We describe a simple and robust method for determining the geometry of segmented X-ray detectors using measurements obtained by serial crystallography. By comparing the location of observed Bragg peaks to the spot locations predicted from the crystal indexing procedure, the position, rotation and distance of each module relative to the interaction region can be refined. We show that the refined detector geometry greatly improves the results of experiments. PMID:26561117

  7. Analysis of coronal and chromospheric hard X-ray sources in an eruptive solar flare

    Science.gov (United States)

    Zimovets, Ivan; Golovin, Dmitry; Livshits, Moisey; Vybornov, Vadim; Sadykov, Viacheslav; Mitrofanov, Igor

    We have analyzed hard X-ray emission of an eruptive solar flare on 3 November 2010. The entire flare region was observed by the STEREO-B spacecraft. This gave us an information that chromospheric footpoints of flare magnetic loops were behind the east solar limb for an earth observer. Hard X-ray emission from the entire flare region was detected by the High Energy Neutron Detector (HEND) onboard the 2001 Mars Odyssey spacecraft while hard X-rays from the coronal part of the flare region were detected by the RHESSI. This rare situation has allowed us to investigate both coronal and chromospheric sources of hard X-ray emission separately. Flare impulsive phase was accompanied by eruption of a magnetic flux rope and formation of a plasmoid detected by the AIA/SDO in the EUV range. Two coronal hard X-ray sources (S_{1} and S_{2}) were detected by the RHESSI. The upper source S_{1} coincided with the plasmoid and the lower source S_{2} was near the tops of the underlying flare loops that is in accordance with the standard model of eruptive flares. Imaging spectroscopy with the RHESSI has allowed to measure energetic spectra of hard X-ray emission from the S_{1} and S_{2} sources. At the impulsive phase peak they have power-law shape above ≈ 15 keV with spectral slopes gamma_{S_{1}}=3.46 ± 1.58 and gamma_{S_{2}}=4.64 ± 0.12. Subtracting spatially integrated spectrum of coronal hard X-ray emission measured by the RHESSI from the spectrum measured by the HEND we found spectrum of hard X-rays emitted from the footpoints of the flare loops (source S_{0}). This spectrum has a power-law shape with gamma_{S_{0}}=2.21 ± 0.57. It is shown that it is not possible to explain the measured spectra of the S_{2} and S_{0} sources in frames of the thin and thick target models respectively if we assume that electrons were accelerated in the energy release site situated below the plasmoid and above the flare loops as suggested by the standard flare model. To resolve the contradiction

  8. Thermal detectors as single photon X-ray spectrometers

    Science.gov (United States)

    Moseley, S. H.; Kelley, R. L.; Mather, J. C.; Mushotzky, R. F.; Szymkowiak, A. E.; Mccammon, D.

    1985-01-01

    In a thermal detector employed for X-ray spectroscopy applications, the energy of an X-ray is converted to heat in a small mass, and the energy of that X-ray inferred from the size of the temperature rise. The present investigation is concerned with the possibility to make an extremely low heat capacity calorimeter which can be employed as a thermal detector. Several types of calorimeters were fabricated and tested at temperatures as low as approximately 0.05 K. The obtained devices make use of thermistors constructed of melt-doped silicon, nuclear transmutation doped (NTD) germanium, and ion-implanted silicon with a variety of materials for the support and electrical leads. The utility of these microcalorimeters as X-ray spectrometers could be verified.

  9. Hard X-ray Spectrographs with Resolution Beyond 100 micro-eV

    CERN Document Server

    Shvyd'ko, Yuri; Mundboth, Kiran; Kim, Jungho

    2013-01-01

    Spectrographs take snapshots of photon spectra with array detectors by dispersing photons of different energies into distinct directions and spacial locations. Spectrographs require optics with a large angular dispersion rate as the key component. In visible light optics diffraction gratings are used for this purpose. In the hard x-ray regime, achieving large dispersion rates is a challenge. Here we show that multi-crystal, multi-Bragg-reflection arrangements feature cumulative angular dispersion rates almost two orders of magnitude larger than those attainable with a single Bragg reflection. As a result, the multi-crystal arrangements become potential dispersing elements of hard x-ray spectrographs. The hard x-ray spectrograph principles are demonstrated by imaging a spectrum of photons with a record high resolution of $\\Delta E \\simeq 90 \\mu$eV in hard x-ray regime, using multi-crystal optics as dispersing element. The spectrographs can boost research using inelastic ultra-high-resolution x-ray spectroscopi...

  10. Avalanche Photodiodes as Fast X-ray Detectors.

    Science.gov (United States)

    Kishimoto, S

    1998-05-01

    An avalanche photodiode (APD) detector provides a sub-nanosecond time resolution and an output rate of more than 10(8) counts s(-1) of synchrotron X-rays. Moreover, the APD has the advantage of low noise. A review of recent developments of detectors using APD devices designed for X-ray experiments is presented in this paper. One of the detectors has an excellent time response of 100 ps resolution and a narrow width on its response function, 1.4 ns at 10(-5) maximum. The other consists of a stack of four diodes and has a transmission structure. The stacked detector improved the efficiency for X-rays, e.g. 55% at 16.53 keV. The output rates reached more than 10(8) counts s(-1) per device.

  11. Improved x-ray spectroscopy with room temperature CZT detectors.

    Science.gov (United States)

    Fritz, Shannon G; Shikhaliev, Polad M; Matthews, Kenneth L

    2011-09-07

    Compact, room temperature x-ray spectroscopy detectors are of interest in many areas including diagnostic x-ray imaging, radiation protection and dosimetry. Room temperature cadmium zinc telluride (CZT) semiconductor detectors are promising candidates for these applications. One of the major problems for CZT detectors is low-energy tailing of the energy spectrum due to hole trapping. Spectral post-correction methods to correct the tailing effect do not work well for a number of reasons; thus it is advisable to eliminate the hole trapping effect in CZT using physical methods rather than correcting an already deteriorated energy spectrum. One method is using a CZT detector with an electrode configuration which modifies the electric field in the CZT volume to decrease low-energy tailing. Another method is to irradiate the CZT surface at a tilted angle, which modifies depth of interaction to decrease low-energy tailing. Neither method alone, however, eliminates the tailing effect. In this work, we have investigated the combination of modified electric field and tilted angle irradiation in a single detector to further decrease spectral tailing. A planar CZT detector with 10 × 10 × 3 mm³ size and CZT detector with 5 × 5 × 5 mm³ size and cap-shaped electrode were used in this study. The cap-shaped electrode (referred to as CAPture technology) modifies the electric field distribution in the CZT volume and decreases the spectral tailing effect. The detectors were investigated at 90° (normal) and 30° (tilted angle) irradiation modes. Two isotope sources with 59.6 and 122 keV photon energies were used for gamma-ray spectroscopy experiments. X-ray spectroscopy was performed using collimated beams at 60, 80 and 120 kVp tube voltages, in both normal and tilted angle irradiation. Measured x-ray spectra were corrected for K x-ray escape fractions that were calculated using Monte Carlo methods. The x-ray spectra measured with tilted angle CAPture detector at 60, 80 and 120

  12. Injection molded polymeric hard X-ray lenses

    DEFF Research Database (Denmark)

    Stöhr, Frederik; Simons, Hugh; Jakobsen, Anders Clemen;

    2015-01-01

    A novel and economical approach for fabricating compound refractive lenses for the purpose of focusing hard X-rays is described. A silicon master was manufactured by UV-lithography and deep reactive ion etching (DRIE). Sacrificial structures were utilized, which enabled accurate control of the et......A novel and economical approach for fabricating compound refractive lenses for the purpose of focusing hard X-rays is described. A silicon master was manufactured by UV-lithography and deep reactive ion etching (DRIE). Sacrificial structures were utilized, which enabled accurate control...... of the etching profile and were removed after DRIE. By electroplating, an inverse nickel sample was obtained, which was used as a mold insert in a commercial polymer injection molding machine. A prototype lens made of polyethylene with a focal length of 350 mm was tested using synchrotron radiation at photon...

  13. Expectation Maximization for Hard X-ray Count Modulation Profiles

    CERN Document Server

    Benvenuto, Federico; Piana, Michele; Massone, Anna Maria

    2013-01-01

    This paper is concerned with the image reconstruction problem when the measured data are solar hard X-ray modulation profiles obtained from the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI)} instrument. Our goal is to demonstrate that a statistical iterative method classically applied to the image deconvolution problem is very effective when utilized for the analysis of count modulation profiles in solar hard X-ray imaging based on Rotating Modulation Collimators. The algorithm described in this paper solves the maximum likelihood problem iteratively and encoding a positivity constraint into the iterative optimization scheme. The result is therefore a classical Expectation Maximization method this time applied not to an image deconvolution problem but to image reconstruction from count modulation profiles. The technical reason that makes our implementation particularly effective in this application is the use of a very reliable stopping rule which is able to regularize the solution providing, ...

  14. Anisotropic imaging performance in indirect x-ray imaging detectors.

    Science.gov (United States)

    Badano, Aldo; Kyprianou, Iacovos S; Sempau, Josep

    2006-08-01

    We report on the variability in imaging system performance due to oblique x-ray incidence, and the associated transport of quanta (both x rays and optical photons) through the phosphor, in columnar indirect digital detectors. The analysis uses MANTIS, a combined x-ray, electron, and optical Monte Carlo transport code freely available. We describe the main features of the simulation method and provide some validation of the phosphor screen models considered in this work. We report x-ray and electron three-dimensional energy deposition distributions and point-response functions (PRFs), including optical spread in columnar phosphor screens of thickness 100 and 500 microm, for 19, 39, 59, and 79 keV monoenergetic x-ray beams incident at 0 degrees, 10 degrees, and 15 degrees. In addition, we present pulse-height spectra for the same phosphor thickness, x-ray energies, and angles of incidence. Our results suggest that the PRF due to the phosphor blur is highly nonsymmetrical, and that the resolution properties of a columnar screen in a tomographic, or tomosynthetic imaging system varies significantly with the angle of x-ray incidence. Moreover, we find that the noise due to the variability in the number of light photons detected per primary x-ray interaction, summarized in the information or Swank factor, is somewhat independent of thickness and incidence angle of the x-ray beam. Our results also suggest that the anisotropy in the PRF is not less in screens with absorptive backings, while the noise introduced by variations in the gain and optical transport is larger. Predictions from MANTIS, after additional validation, can provide the needed understanding of the extent of such variations, and eventually, lead to the incorporation of the changes in imaging performance with incidence angle into the reconstruction algorithms for volumetric x-ray imaging systems.

  15. Experimental study of hard X-rays emitted from meter-scale positive discharges in air

    CERN Document Server

    Kochkin, P O; van Deursen, A P J; Ebert, U

    2012-01-01

    We investigate structure and evolution of long positive spark breakdown; and we study at which stage pulses of hard X-rays are emitted. Positive high-voltage pulses of standardized lightning impulse wave form of about 1 MV were applied to about 1 meter of ambient air. The discharge evolution was imaged with a resolution of tens of nanoseconds with an intensified CCD camera. LaBr3(Ce+) scintillation detectors recorded the X-rays emitted during the process. The voltage and the currents on both electrodes were measured synchronously. All measurements indicate that first a large and dense corona of positive streamers emerges from the high voltage electrode. When they approach the grounded electrode, negative counter-streamers emerge there, and the emission of hard X-rays coincides with the connection of the positive streamers with the negative counter-streamers.

  16. Bulk sensitive hard x-ray photoemission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Patt, M., E-mail: m.patt@fz-juelich.de; Wiemann, C. [Peter Grünberg Institute (PGI-6) and JARA-FIT, Research Center Jülich, D-52425 Jülich (Germany); Weber, N.; Escher, M.; Merkel, M. [Focus GmbH, Neukirchner Str. 2, D-65510 Hünstetten (Germany); Gloskovskii, A.; Drube, W. [DESY Photon Science, Deutsches Elektronen-Synchrotron, D-22603 Hamburg (Germany); Schneider, C. M. [Peter Grünberg Institute (PGI-6) and JARA-FIT, Research Center Jülich, D-52425 Jülich (Germany); Fakultät f. Physik and Center for Nanointegration Duisburg-Essen (CeNIDE), Universität Duisburg-Essen, D-47048 Duisburg (Germany)

    2014-11-15

    Hard x-ray photoelectron spectroscopy (HAXPES) has now matured into a well-established technique as a bulk sensitive probe of the electronic structure due to the larger escape depth of the highly energetic electrons. In order to enable HAXPES studies with high lateral resolution, we have set up a dedicated energy-filtered hard x-ray photoemission electron microscope (HAXPEEM) working with electron kinetic energies up to 10 keV. It is based on the NanoESCA design and also preserves the performance of the instrument in the low and medium energy range. In this way, spectromicroscopy can be performed from threshold to hard x-ray photoemission. The high potential of the HAXPEEM approach for the investigation of buried layers and structures has been shown already on a layered and structured SrTiO{sub 3} sample. Here, we present results of experiments with test structures to elaborate the imaging and spectroscopic performance of the instrument and show the capabilities of the method to image bulk properties. Additionally, we introduce a method to determine the effective attenuation length of photoelectrons in a direct photoemission experiment.

  17. Hard X-ray emission of Sco X-1

    CERN Document Server

    Revnivtsev, Mikhail G; Churazov, Eugene M; Krivonos, Roman A

    2014-01-01

    We study hard X-ray emission of the brightest accreting neutron star Sco X-1 with INTEGRAL observatory. Up to now INTEGRAL have collected ~4 Msec of deadtime corrected exposure on this source. We show that hard X-ray tail in time average spectrum of Sco X-1 has a power law shape without cutoff up to energies ~200-300 keV. An absence of the high energy cutoff does not agree with the predictions of a model, in which the tail is formed as a result of Comptonization of soft seed photons on bulk motion of matter near the compact object. The amplitude of the tail varies with time with factor more than ten with the faintest tail at the top of the so-called flaring branch of its color-color diagram. We show that the minimal amplitude of the power law tail is recorded when the component, corresponding to the innermost part of optically thick accretion disk, disappears from the emission spectrum. Therefore we show that the presence of the hard X-ray tail may be related with the existence of the inner part of the optica...

  18. Sub-Picosecond Tunable Hard X-Ray Undulator Source for Laser/X-Ray Pump-Probe Experiments

    Science.gov (United States)

    Ingold, G.; Beaud, P.; Johnson, S.; Streun, A.; Schmidt, T.; Abela, R.; Al-Adwan, A.; Abramsohn, D.; Böge, M.; Grolimund, D.; Keller, A.; Krasniqi, F.; Rivkin, L.; Rohrer, M.; Schilcher, T.; Schmidt, T.; Schlott, V.; Schulz, L.; van der Veen, F.; Zimoch, D.

    2007-01-01

    The FEMTO source under construction at the μXAS beamline is designed to enable tunable time-resolved laser/x-ray absorption and diffraction experiments in photochemistry and condensed matter with ps- and sub-ps resolution. The design takes advantage of (1) the highly stable operation of the SLS storage ring, (2) the reliable high harmonic operation of small gap, short period undulators to generate hard x-rays with energy 3-18 keV at 2.4 GeV beam energy, and (3) the progress in high power, high repetition rate fs solid-state laser technology to employ laser/e-beam `slicing' to reach a time resolution of ultimately 100 fs. The source will profit from the inherently synchronized pump (laser I: 100 fs, 2 mJ, 1 kHz) and probe (sliced X-rays, laser II: 50 fs, 5 mJ, 1 kHz) pulses, and from the excellent stability of the SLS storage ring which is operated in top-up mode and controlled by a fast orbit feedback (FOFB). Coherent radiation emitted at THz frequencies by the sliced 100 fs electron bunches will be monitored as on-line cross-correlation signal to keep the laser-electron beam interaction at optimum. The source is designed to provide at 8 keV (100 fs) a monochromized flux of 104 ph/s/0.01% bw (Si crystal monochromator) and 106 ph/s/1.5% bw (multilayer monochromator) at the sample. It is operated in parasitic mode using a hybrid bunch filling pattern. Because of the low intensity measurements are carried out repetitively over many shots using refreshing samples and gated detectors. `Diffraction gating' experiments will be used to characterize the sub-ps X-ray pulses.

  19. The Swift/BAT Hard X-ray Transient Monitor

    CERN Document Server

    Krimm, Hans A; Corbet, Robin H D; Perlman, Aaron B; Romano, Patrizia; Kennea, Jamie A; Bloom, Joshua S; Barthelmy, Scott D; Baumgartner, Wayne H; Cummings, James R; Gehrels, Neil; Lien, Amy Y; Markwardt, Craig B; Palmer, David M; Sakamoto, Taka; Stamatikos, Michael; Ukwatta, Tilan N

    2013-01-01

    The Swift/Burst Alert Telescope (BAT) hard X-ray transient monitor provides near real-time coverage of the X-ray sky in the energy range 15-50 keV. The BAT observes 88% of the sky each day with a detection sensitivity of 5.3 mCrab for a full-day observation and a time resolution as fine as 64 seconds. The three main purposes of the monitor are (1) the discovery of new transient X-ray sources, (2) the detection of outbursts or other changes in the flux of known X-ray sources, and (3) the generation of light curves of more than 900 sources spanning over eight years. The primary interface for the BAT transient monitor is a public web page. Between 2005 February 12 and 2013 April 30, 245 sources have been detected in the monitor, 146 of them persistent and 99 detected only in outburst. Among these sources, 17 were previously unknown and were discovered in the transient monitor. In this paper, we discuss the methodology and the data processing and filtering for the BAT transient monitor and review its sensitivity ...

  20. X-ray microscopy of soft and hard human tissues

    Energy Technology Data Exchange (ETDEWEB)

    Müller, Bert, E-mail: bert.mueller@unibas.ch; Schulz, Georg, E-mail: georg.schulz@unibas.ch; Deyhle, Hans, E-mail: hans.deyhle@unibas.ch; Stalder, Anja K., E-mail: anja.stalder@unibas.ch; Ilgenstein, Bernd, E-mail: bernd.ilgenstein@unibas.ch; Holme, Margaret N., E-mail: m.holme@imperial.ac.uk; Hieber, Simone E., E-mail: simone.hieber@unibas.ch [Biomaterials Science Center (BMC), University of Basel, c/o University Hospital, 4031 Basel (Switzerland); Weitkamp, Timm, E-mail: weitkamp@synchrotron-soleil.fr [Beamline ANATOMIX, Synchrotron Soleil, L’Orme des Merisiers, Saint Aubin - B.P. 48, 91192 Gif sur Yvette (France); Beckmann, Felix, E-mail: felix.beckmann@hzg.de [Institute of Materials Research, Helmholtz-Zentrum Geesthacht, Max-Planck-Str. 1, 21502 Geesthacht, c/o HZG at DESY, Notkestr. 85, 22607 Hamburg (Germany)

    2016-01-28

    The simultaneous post mortem visualization of soft and hard tissues using absorption-based CT remains a challenge. If the photon energy is optimized for the visualization of hard tissue, the surrounding soft tissue components are almost X-ray transparent. Therefore, the combination with other modalities such as phase-contrast CT, magnetic resonance microscopy, and histology is essential to detect the anatomical features. The combination of the 2D and 3D data sets using sophisticated segmentation and registration tools allows for conclusions about otherwise inaccessible anatomical features essential for improved patient treatments.

  1. Artefacts of X-ray area detectors caused by diffraction

    CERN Document Server

    Gollwitzer, Christian

    2013-01-01

    When an X-ray area detector based on a single crystalline material, for instance a state of the art hybrid-pixel detector, is illuminated from a point source by monochromatic radiation, a pattern of lines appears, which overlays the detected image. These lines can easily be found by scattering experiments with smooth patterns such as small angle X-ray scattering. The origin of this effect is Bragg reflection in the absorber of the detector. We present experimental images over a photon energy range from 3.4 keV to 10 keV together with a theoretical analysis. The patterns can be exploited to check the alignment of the detector surface to the direct beam, and of individual detector modules to each other for modular detectors, as well as for energy calibration of the radiation.

  2. [Flat-panel detectors in X-ray systems].

    Science.gov (United States)

    Spahn, M; Heer, V; Freytag, R

    2003-05-01

    For all application segments X-ray systems with flat-panel detectors increasingly enter the market. In digital radiography,mammography and cardiologic angiography flat-panel detectors are already well established while they are made ready for market introduction in general angiography and fluoroscopy. Two flat-panel detector technologies are available. One technology is based on an indirect conversion process of X-rays while the other one uses a direct conversion method. For radiography and dynamic applications the indirect method provides substantial advantages, while the direct method has some benefits for mammography. In radiography and mammography flat-panel detectors lead to clear improvements with respect to workflow, image quality and dose reduction potentials. These improvements are fostered by the immediate availability of the image, the large dynamic range and the high sensitivity to X-rays. New applications and the use of complex image processing algorithms have the potential to enlarge the present diagnostic range of applications. Up to now, image intensifiers are still the well-established technology for angiography and fluoroscopy. Nevertheless flat-panel detectors begin to enter this field, especially in cardiologic angiography. Characteristics of flat-panel detectors such as the availability of distortion-free images, the excellent contrast resolution, the large dynamic range, the high sensitivity to X-rays and the usability in magnetic fields provide the basis for improved and new diagnostic and interventional methods.

  3. Hard X-rays in–soft X-rays out: An operando piggyback view deep into a charging lithium ion battery with X-ray Raman spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Braun, Artur, E-mail: artur.braun@alumni.ethz.ch [Laboratory for High Performance Ceramics. Empa, Swiss Federal Laboratories for Materials Science and Technology, CH-8600 Dübendorf (Switzerland); Nordlund, Dennis [Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, Menlo Park, CA 94720 (United States); Song, Seung-Wan [Department of Fine Chemical Engineering & Applied Chemistry, Chungnam National University, Daejeon 305-764 (Korea, Republic of); Huang, Tzu-Wen [Laboratory for High Performance Ceramics. Empa, Swiss Federal Laboratories for Materials Science and Technology, CH-8600 Dübendorf (Switzerland); Sokaras, Dimosthenis [Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, Menlo Park, CA 94720 (United States); Liu, Xiasong; Yang, Wanli [Advanced Light Source, Ernest Orlando Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Weng, Tsu-Chien [Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, Menlo Park, CA 94720 (United States); Liu, Zhi [Advanced Light Source, Ernest Orlando Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)

    2015-04-15

    Graphical abstract: - Abstract: For lithium intercalation battery electrodes, understanding of the electronic structure of bulk and surface is essential for their operation and functionality. Soft X-rays are excellent probes for such electronic structure information, but soft X-rays are predominantly surface sensitive and thus cannot probe the bulk. Moreover, soft X-rays hardly permit meaningful in situ and operando studies in battery assemblies. We show here how we penetrate with hard X-rays (>10 keV) in situ a lithium cell, containing a manganite-based cathode. Through X-ray Raman spectroscopy we extract the Mn 2p multiplet from the entire cathode material, thus obtaining bulk-sensitive electronic structure information during battery charging and discharging.

  4. Study of X-ray Imaging of GEM Detector

    Institute of Scientific and Technical Information of China (English)

    LI; Xiao-mei; HU; Shou-yang; JIAN; Si-yu; ZHOU; Jing; LI; Xing-long; LIANG; Hao; ZHOU; Shu-hua

    2015-01-01

    A 10cm×10cm GEM detector made by 3GEM foils was used in the X-ray imaging experiment.2-D strips readout mode was used and each dimension has 256channels with a pitch of 400micrometer.APV25front-end readout chip was introduced in the detector,and the backplane connectors were improved in order to adapt the electronics with GEM detector.Since each

  5. Hard X-ray sources from miniature plasma focus devices

    Energy Technology Data Exchange (ETDEWEB)

    Raspa, V. [Buenos Aires Univ., PLADEMA, CONICET and INFIP (Argentina); Silva, P.; Moreno, J.; Zambra, M.; Soto, L. [Comision Chilena de Energia Nuclear, Santiago (Chile)

    2004-07-01

    As first stage of a program to design a repetitive pulsed radiation generator for industrial applications, two miniature plasma foci have been designed and constructed at the Chilean commission of nuclear energy. The devices operate at an energy level of the order of tens of joules (PF-50 J, 160 nF capacitor bank, 20-35 kV, 32-100 J, {approx} 150 ns time to peak current) and hundred of joules (PF-400 J, 880 nF, 20-35 kV, 176-539 J, {approx} 300 ns time to peak current). Hard X-rays are being studied in these devices operating with hydrogen. Images of metallic plates with different thickness were obtained on commercial radiographic film, Agfa Curix ST-G2, in order to characterize the energy of the hard X-ray outside of the discharge chamber of PF-400 J. An effective energy of the order of 90 keV was measured under those conditions. X ray images of different metallic objects also have been obtained. (authors)

  6. A multiple CCD X-ray detector and its first operation with synchrotron radiation X-ray beam

    CERN Document Server

    Suzuki, M; Kumasaka, T; Sato, K; Toyokawa, H; Aries, I F; Jerram, P A; Ueki, T

    1999-01-01

    A 4x4 array structure of 16 identical CCD X-ray detector modules, called the multiple CCD X-ray detector system (MCCDX), was submitted to its first synchrotron radiation experiment at the protein crystallography station of the RIKEN beamline (BL45XU) at the SPring-8 facility. An X-ray diffraction pattern of cholesterol powder was specifically taken in order to investigate the overall system performance.

  7. Hard X-rays from hybrid X pinches

    Energy Technology Data Exchange (ETDEWEB)

    Shelkovenko, T. A., E-mail: tc50@cornell.edu; Pikuz, S. A., E-mail: tc50@cornell.edu [Cornell University, Ithaca, New York, 14853, USA and P. N. Lebedev Institute, 53 Leninskii Prospect, Moscow, 119991 (Russian Federation); Hoyt, C. L.; Cahill, A. D.; Hammer, D. A. [Cornell University, Ithaca, New York, 14853 (United States); Tilikin, I. N.; Mingaleev, A. R.; Agafonov, A. V. [P. N. Lebedev Institute, 53 Leninskii Prospect, Moscow, 119991 (Russian Federation)

    2014-12-15

    X pinches are well known to produce very small, dense plasma pinches (“hot spots”) that emit short bursts of 1.5–8 keV radiation. Hard X-ray radiation in the 8–100 keV range is also emitted, only a small portion of which is associated with the X-pinch hot spot. In hybrid X-pinches, the “long” X-ray pulse is terminated by fast closure of the gap between the two conical electrodes by rapidly expanding electrode plasmas. The temporal, spectral, and spatial properties of this higher energy radiation, 10 – 60 keV, have been studied. This radiation was used for point-projection imaging with magnification between 1.5 and 3, and spatial resolution less than100 micrometers was demonstrated.

  8. Deducing Electron Properties From Hard X-Ray Observations

    CERN Document Server

    Kontar, E P; Emslie, A G; Hajdas, W; Holman, G D; Hurford, G J; Kasparova, J; Mallik, P C V; Massone, A M; McConnell, M L; Piana, M; Prato, M; Schmahl, E J; Suarez-Garcia, E

    2011-01-01

    X-radiation from energetic electrons is the prime diagnostic of flare-accelerated electrons. The observed X-ray flux (and polarization state) is fundamentally a convolution of the cross-section for the hard X-ray emission process(es) in question with the electron distribution function, which is in turn a function of energy, direction, spatial location and time. To address the problems of particle propagation and acceleration one needs to infer as much information as possible on this electron distribution function, through a deconvolution of this fundamental relationship. This review presents recent progress toward this goal using spectroscopic, imaging and polarization measurements, primarily from the \\textit{Reuven Ramaty High Energy Solar Spectroscopic Imager} ({\\em RHESSI}). Previous conclusions regarding the energy, angular (pitch angle) and spatial distributions of energetic electrons in solar flares are critically reviewed. We discuss the role and the observational evidence of several radiation processe...

  9. Organic semiconducting single crystals as next generation of low-cost, room-temperature electrical X-ray detectors.

    Science.gov (United States)

    Fraboni, Beatrice; Ciavatti, Andrea; Merlo, Francesco; Pasquini, Luca; Cavallini, Anna; Quaranta, Alberto; Bonfiglio, Annalisa; Fraleoni-Morgera, Alessandro

    2012-05-02

    Direct, solid-state X-ray detectors based on organic single crystals are shown to operate at room temperature, in air, and at voltages as low as a few volts, delivering a stable and reproducible linear response to increasing X-ray dose rates, with notable radiation hardness and resistance to aging. All-organic and optically transparent devices are reported.

  10. Deducing Electron Properties from Hard X-ray Observations

    Science.gov (United States)

    Kontar, E. P.; Brown, J. C.; Emslie, A. G.; Hajdas, W.; Holman, G. D.; Hurford, G. J.; Kašparová, J.; Mallik, P. C. V.; Massone, A. M.; McConnell, M. L.; Piana, M.; Prato, M.; Schmahl, E. J.; Suarez-Garcia, E.

    2011-09-01

    X-radiation from energetic electrons is the prime diagnostic of flare-accelerated electrons. The observed X-ray flux (and polarization state) is fundamentally a convolution of the cross-section for the hard X-ray emission process(es) in question with the electron distribution function, which is in turn a function of energy, direction, spatial location and time. To address the problems of particle propagation and acceleration one needs to infer as much information as possible on this electron distribution function, through a deconvolution of this fundamental relationship. This review presents recent progress toward this goal using spectroscopic, imaging and polarization measurements, primarily from the Reuven Ramaty High Energy Solar Spectroscopic Imager ( RHESSI). Previous conclusions regarding the energy, angular (pitch angle) and spatial distributions of energetic electrons in solar flares are critically reviewed. We discuss the role and the observational evidence of several radiation processes: free-free electron-ion, free-free electron-electron, free-bound electron-ion, photoelectric absorption and Compton backscatter (albedo), using both spectroscopic and imaging techniques. This unprecedented quality of data allows for the first time inference of the angular distributions of the X-ray-emitting electrons and improved model-independent inference of electron energy spectra and emission measures of thermal plasma. Moreover, imaging spectroscopy has revealed hitherto unknown details of solar flare morphology and detailed spectroscopy of coronal, footpoint and extended sources in flaring regions. Additional attempts to measure hard X-ray polarization were not sufficient to put constraints on the degree of anisotropy of electrons, but point to the importance of obtaining good quality polarization data in the future.

  11. X-Ray and Gamma-Ray Radiation Detector

    DEFF Research Database (Denmark)

    2015-01-01

    Disclosed is a semiconductor radiation detector for detecting X-ray and / or gamma-ray radiation. The detector comprises a converter element for converting incident X-ray and gamma-ray photons into electron-hole pairs, at least one cathode, a plurality of detector electrodes arranged with a pitch...... (P) along a first axis, a plurality of drift electrodes, a readout circuitry being configured to read out signals from the plurality of detector electrodes and a processing unit connected to the readout circuitry and being configured to detect an event in the converter element. The readout circuitry...... is further configured to read out signals from the plurality of drift electrodes, and the processing unit is further configured to estimate a location of the event along the first axis by processing signals obtained from both the detector electrodes and the drift electrodes, the location of the event along...

  12. Hard X-Ray Burst Detected From Caltech Plasma Jet Experiment Magnetic Reconnection Event

    Science.gov (United States)

    Marshall, Ryan S.; Bellan, Paul M.

    2016-10-01

    In the Caltech plasma jet experiment a 100 kA MHD driven jet becomes kink unstable leading to a Rayleigh-Taylor instability that quickly causes a magnetic reconnection event. Movies show that the Rayleigh-Taylor instability is simultaneous with voltage spikes across the electrodes that provide the current that drives the jet. Hard x-rays between 4 keV and 9 keV have now been observed using an x-ray scintillator detector mounted just outside of a kapton window on the vacuum chamber. Preliminary results indicate that the timing of the x-ray burst coincides with a voltage spike on the electrodes occurring in association with the Rayleigh-Taylor event. The x-ray signal accompanies the voltage spike and Rayleigh-Taylor event in approximately 50% of the shots. A possible explanation for why the x-ray signal is sometimes missing is that the magnetic reconnection event may be localized to a specific region of the plasma outside the line of sight of the scintillator. The x-ray signal has also been seen accompanying the voltage spike when no Rayleigh-Taylor is observed. This may be due to the interframe timing on the camera being longer than the very short duration of the Rayleigh-Taylor instability.

  13. Characterisation and application of a laser-based hard x-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Graetz, M

    1998-11-01

    Hard X-rays are generated by focusing 110 fs laser pulses with intensities of about 1017 W/cm{sup 2} onto solid metal targets. Characteristic properties of this X-ray source are the small source size, the short pulse duration and the high peak flux. The aim of the present work was to characterise this X-ray source and to demonstrate possible applications. A comparison with other X-ray sources and conventional imaging techniques is made. Characterising measurements were performed, including source size, emission spectrum, temporal behaviour, source stability and the influence of various laser parameters. The emission spectrum was measured using both energy-dispersive solid-state detectors and wavelength-dispersive crystal spectroscopy. The conversion efficiency from laser light to X-ray radiation was measured for different target materials. The laser ablation from different targets was studied. The feasibility of special imaging techniques, e.g. differential imaging and time-gated imaging, was investigated both theoretically and experimentally. Differential imaging allows for selective imaging of contrast agents, while time-gated imaging can reduce the influence of scattered radiation in X-ray imaging. Time-gated imaging was demonstrated in different imaging geometries, both for planar imaging and computed tomography imaging. Reasonable agreement between theoretically calculated values and experimental results was obtained 120 refs, figs, tabs

  14. Development of an X-ray pixel detector with multi-port charge-coupled device for X-ray free-electron laser experiments

    Energy Technology Data Exchange (ETDEWEB)

    Kameshima, Takashi [JASRI, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Ono, Shun; Kudo, Togo; Ozaki, Kyosuke; Kirihara, Yoichi; Kobayashi, Kazuo; Inubushi, Yuichi [RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Yabashi, Makina; Hatsui, Takaki, E-mail: hatsui@spring8.or.jp [JASRI, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); RIKEN SPring-8 Center, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5148 (Japan); Horigome, Toshio [Institute for Molecular Science, Myodaiji, Okazaki 444-8585 (Japan); Holland, Andrew; Holland, Karen [XCam, Ltd, 2 Stone Circle Road, Round Spinney Industrial Estate, Northampton NN3 8RF (United Kingdom); Burt, David [e2v, 106 Waterhouse Lane, Chelmsford, Essex CM1 2QU (United Kingdom); Murao, Hajime [Meisei Electric Co. Ltd, Naganuma 2223, Isesaki, Gunma 372-8585 (Japan)

    2014-03-15

    This paper presents development of an X-ray pixel detector with a multi-port charge-coupled device (MPCCD) for X-ray Free-Electron laser experiments. The fabrication process of the CCD was selected based on the X-ray radiation hardness against the estimated annual dose of 1.6 × 10{sup 14} photon/mm{sup 2}. The sensor device was optimized by maximizing the full well capacity as high as 5 Me- within 50 μm square pixels while keeping the single photon detection capability for X-ray photons higher than 6 keV and a readout speed of 60 frames/s. The system development also included a detector system for the MPCCD sensor. This paper summarizes the performance, calibration methods, and operation status.

  15. Ultrafast Time-Resolved Hard X-Ray Emission Spectroscopy on a Tabletop

    Science.gov (United States)

    Miaja-Avila, Luis; O'Neil, Galen C.; Joe, Young I.; Alpert, Bradley K.; Damrauer, Niels H.; Doriese, William B.; Fatur, Steven M.; Fowler, Joseph W.; Hilton, Gene C.; Jimenez, Ralph; Reintsema, Carl D.; Schmidt, Daniel R.; Silverman, Kevin L.; Swetz, Daniel S.; Tatsuno, Hideyuki; Ullom, Joel N.

    2016-07-01

    Experimental tools capable of monitoring both atomic and electronic structure on ultrafast (femtosecond to picosecond) time scales are needed for investigating photophysical processes fundamental to light harvesting, photocatalysis, energy and data storage, and optical display technologies. Time-resolved hard x-ray (>3 keV ) spectroscopies have proven valuable for these measurements due to their elemental specificity and sensitivity to geometric and electronic structures. Here, we present the first tabletop apparatus capable of performing time-resolved x-ray emission spectroscopy. The time resolution of the apparatus is better than 6 ps. By combining a compact laser-driven plasma source with a highly efficient array of microcalorimeter x-ray detectors, we are able to observe photoinduced spin changes in an archetypal polypyridyl iron complex [Fe (2 ,2'-bipyridine)3]2 + and accurately measure the lifetime of the quintet spin state. Our results demonstrate that ultrafast hard x-ray emission spectroscopy is no longer confined to large facilities and now can be performed in conventional laboratories with 10 times better time resolution than at synchrotrons. Our results are enabled, in part, by a 100- to 1000-fold increase in x-ray collection efficiency compared to current techniques.

  16. Generation of hard X-ray radiation using the triboelectric effect

    Energy Technology Data Exchange (ETDEWEB)

    Ruehl, Maximilian; Gutmann, Emanuel; Mehner, Erik; Stoecker, Hartmut [Nachwuchsgruppe Nanostrukturphysik, Institut fuer Strukturphysik, TU Dresden (Germany); Meyer, Dirk C. [Institut fuer Experimentelle Physik, TU Bergakademie Freiberg (Germany)

    2010-07-01

    To meet the demands of upcoming imaging for medical demands and scientific methods for structure investigation, generation of X-rays using miniaturized radiation sources is an interesting field of research. Beside approaches based on the ionizing and electron accelerating properties of high electric fields around pyroelectric crystals also the use of a tribomicroplasma generated in the vicinity of the peeling point of two different polymers is promising. We report on the generation of hard X-ray radiation by crawling various peeling tapes in a medium vacuum. Beside vacuum housing and pumps as instrumentation only an electric motor, two rolls and a metal foil as target material are necessary. The spectral distribution of thus generated X-rays was analyzed using an energy dispersive Si(Li) detector. In dependence of peeling speed, pressure and choice of polymer material electrons with energies high enough to excite characteristic X-ray emission in the hard X-ray region are produced. The results are discussed in terms of theory of triboelectricity.

  17. X-ray Peltier cooled detectors for X-ray fluorescence analysis

    Energy Technology Data Exchange (ETDEWEB)

    Loupilov, A. E-mail: bsi@bsi.lv; Sokolov, A.; Gostilo, V

    2001-06-01

    The recent results on development of X-ray Si(Li), Si-planar and CdTe p-i-n detectors cooled by Peltier coolers for fabrication of laboratory and portable XRF analysers for different applications are discussed. Low detection limits of XRF analysers are provided by increasing of detectors sensitive surface; improvement of their spectrometrical characteristics; decreasing of front-end-electronics noise level; Peltier coolers and vacuum chambers cooling modes optimization. Solution of all mentioned tasks allowed to develop Peltier cooled detectors with the following performances: (1.) Si(Li) detectors: S=20 mm{sup 2}, thickness=3.5 mm, 175 eV (5.9 keV), 430 eV (59.6 keV); S=100 mm{sup 2}; thickness=4.5 mm, 270 eV (5.9 keV), 485 eV (59.6 keV). (2.) Si-planar detector: S=10 mm{sup 2}, thickness=0.4 mm, 230 eV (5.9 keV), 460 eV (59.6 keV). (3.) CdTe p-i-n detectors: S=16 mm{sup 2}, thickness=0.5 mm, 350 eV (5.9 keV), 585 eV (59.6 keV). S=16 mm{sup 2}, thickness=1.2 mm, 310 eV (5.9 keV), 600 eV (59.6 keV). Advantages and disadvantages of all types of detectors for X-ray fluorescence analysis are compared. Spectra are presented. Application of different XRF analysers based on developed detectors in medicine, environmental science, industry, cryminalistics and history of art are demonstrated.

  18. The multi-purpose hard X-ray beamline BL10 at the DELTA storage ring.

    Science.gov (United States)

    Lützenkirchen-Hecht, D; Wagner, R; Szillat, S; Hüsecken, A K; Istomin, K; Pietsch, U; Frahm, Ronald

    2014-07-01

    The layout and the characteristics of the hard X-ray beamline BL10 at the superconducting asymmetric wiggler at the 1.5 GeV Dortmund Electron Accelerator DELTA are described. This beamline is equipped with a Si(111) channel-cut monochromator and is dedicated to X-ray studies in the spectral range from ∼4 keV to ∼16 keV photon energy. There are two different endstations available. While X-ray absorption studies in different detection modes (transmission, fluorescence, reflectivity) can be performed on a designated table, a six-axis kappa diffractometer is installed for X-ray scattering and reflectivity experiments. Different detector set-ups are integrated into the beamline control software, i.e. gas-filled ionization chambers, different photodiodes, as well as a Pilatus 2D-detector are permanently available. The performance of the beamline is illustrated by high-quality X-ray absorption spectra from several reference compounds. First applications include temperature-dependent EXAFS experiments from liquid-nitrogen temperature in a bath cryostat up to ∼660 K by using a dedicated furnace. Besides transmission measurements, fluorescence detection for dilute sample systems as well as surface-sensitive reflection-mode experiments are presented.

  19. CCD sensors in synchrotron X-ray detectors

    Science.gov (United States)

    Strauss, M. G.; Naday, I.; Sherman, I. S.; Kraimer, M. R.; Westbrook, E. M.; Zaluzec, N. J.

    1988-04-01

    The intense photon flux from advanced synchrotron light sources, such as the 7-GeV synchrotron being designed at Argonne, require integrating-type detectors. Charge-coupled devices (CCDs) are well suited as synchrotron X-ray detectors. When irradiated indirectly via a phosphor followed by reducing optics, diffraction patterns of 100 cm 2 can be imaged on a 2 cm 2 CCD. With a conversion efficiency of ˜ 1 CCD electron/X-ray photon, a peak saturation capacity of > 10 6 X-rays can be obtained. A programmable CCD controller operating at a clock frequency of 20 MHz has been developed. The readout rate is 5 × 10 6 pixels/s and the shift rate in the parallel registers is 10 6 lines/s. The test detector was evaluated in two experiments. In protein crystallography diffraction patterns have been obtained from a lysozyme crystal using a conventional rotating anode X-ray generator. Based on these results we expect to obtain at a synchrotron diffraction images at a rate of ˜ 1 frame/s or a complete 3-dimensional data set from a single crystal in ˜ 2 min. In electron energy-loss spectroscopy (EELS), the CCD was used in a parallel detection mode which is similar to the mode array detectors are used in dispersive EXAFS. With a beam current corresponding to 3 × 10 9 electron/s on the detector, a series of 64 spectra were recorded on the CCD in a continuous sequence without interruption due to readout. The frame-to-frame pixel signal fluctuations had σ = 0.4% from which DQE = 0.4 was obtained, where the detector conversion efficiency was 2.6 CCD electrons/X-ray photon. These multiple frame series also showed the time-resolved modulation of the electron microscope optics by stray magnetic fields.

  20. Unfolding X-ray spectra using a flat panel detector.

    Science.gov (United States)

    Gallardo, Sergio; Juste, Belén; Pozuelo, Fausto; Ródenas, José; Querol, Andrea; Verdú, Gumersindo

    2013-01-01

    It is difficult to measure the energy spectrum of X-ray tubes due to the pile up effect produced by the high fluence of photons. Using attenuating materials, appropriate detector devices and the Monte Carlo method, primary X-ray spectrum of these devices can be estimated. In this work, a flat panel detector with a PMMA wedge has been used to obtain a dose curve corresponding to certain working conditions of a radiodiagnostic X-ray tube. The relation between the dose curve recorded by the flat panel and the primary X-ray spectrum is defined by a response function. Normally this function can be approximated by a matrix, which can be obtained by means of the Monte Carlo method. Knowing the measured dose curve and the response matrix, the primary X-ray spectrum can be unfolded. However, there are some problems that strongly affect the applicability of this method: i.e. technical features of the flat panel and inherent characteristics of the involved radiation physics (ill-posed problem). Both aspects are analyzed in this work, concluding that the proposed method can be applied with an acceptable accuracy for spectra without characteristic lines, for instance, tungsten anode in the 50-70 kVp range.

  1. Hard X-ray Spectrographs with Resolution Beyond 100 micro-eV

    OpenAIRE

    Shvyd'ko, Yuri; Stoupin, Stanislav; Mundboth, Kiran; Kim, Jungho

    2012-01-01

    Spectrographs take snapshots of photon spectra with array detectors by dispersing photons of different energies into distinct directions and spacial locations. Spectrographs require optics with a large angular dispersion rate as the key component. In visible light optics diffraction gratings are used for this purpose. In the hard x-ray regime, achieving large dispersion rates is a challenge. Here we show that multi-crystal, multi-Bragg-reflection arrangements feature cumulative angular disper...

  2. Hard-X-ray Zone Plates: Recent Progress

    Directory of Open Access Journals (Sweden)

    Syue-Ren Wu

    2012-09-01

    Full Text Available The technology to focus hard-X-rays (photon energy larger than 1–2 keV has made great progress in the past three years. The progress was particularly spectacular for lenses based on the Fresnel zone plate concept. The spatial resolution notably increased by a factor of three, opening up entirely new domains of application, specifically in biomedical research. As we shall see, this evolution is the result of a painstaking optimization of many different aspects rather than of a single technical breakthrough.

  3. Hard-X-Ray-Induced Multistep Ultrafast Dissociation

    Science.gov (United States)

    Travnikova, Oksana; Marchenko, Tatiana; Goldsztejn, Gildas; Jänkälä, Kari; Sisourat, Nicolas; Carniato, Stéphane; Guillemin, Renaud; Journel, Loïc; Céolin, Denis; Püttner, Ralph; Iwayama, Hiroshi; Shigemasa, Eiji; Piancastelli, Maria Novella; Simon, Marc

    2016-05-01

    Creation of deep core holes with very short (τ ≤1 fs ) lifetimes triggers a chain of relaxation events leading to extensive nuclear dynamics on a few-femtosecond time scale. Here we demonstrate a general multistep ultrafast dissociation on an example of HCl following Cl 1 s →σ* excitation. Intermediate states with one or multiple holes in the shallower core electron shells are generated in the course of the decay cascades. The repulsive character and large gradients of the potential energy surfaces of these intermediates enable ultrafast fragmentation after the absorption of a hard x-ray photon.

  4. Detectors for the future of X-ray imaging.

    Science.gov (United States)

    Aslund, M; Fredenberg, E; Telman, M; Danielsson, M

    2010-01-01

    In recent decades, developments in detectors for X-ray imaging have improved dose efficiency. This has been accomplished with for example, structured scintillators such as columnar CsI, or with direct detectors where the X rays are converted to electric charge carriers in a semiconductor. Scattered radiation remains a major noise source, and fairly inefficient anti-scatter grids are still a gold standard. Hence, any future development should include improved scatter rejection. In recent years, photon-counting detectors have generated significant interest by several companies as well as academic research groups. This method eliminates electronic noise, which is an advantage in low-dose applications. Moreover, energy-sensitive photon-counting detectors allow for further improvements by optimising the signal-to-quantum-noise ratio, anatomical background subtraction or quantitative analysis of object constituents. This paper reviews state-of-the-art photon-counting detectors, scatter control and their application in diagnostic X-ray medical imaging. In particular, spectral imaging with photon-counting detectors, pitfalls such as charge sharing and high rates and various proposals for mitigation are discussed.

  5. The pin pixel detector--X-ray imaging

    CERN Document Server

    Bateman, J E; Derbyshire, G E; Duxbury, D M; Marsh, A S; Simmons, J E; Stephenson, R

    2002-01-01

    The development and testing of a soft X-ray gas pixel detector, which uses connector pins for the anodes is reported. Based on a commercial 100 pin connector block, a prototype detector of aperture 25.4 mm centre dot 25.4 mm can be economically fabricated. The individual pin anodes all show the expected characteristics of small gas detectors capable of counting rates reaching 1 MHz per pin. A 2-dimensional resistive divide readout system has been developed to permit the imaging properties of the detector to be explored in advance of true pixel readout electronics.

  6. A carbon nanotube based x-ray detector

    Science.gov (United States)

    Boucher, Richard A.; Bauch, Jürgen; Wünsche, Dietmar; Lackner, Gerhard; Majumder, Anindya

    2016-11-01

    X-ray detectors based on metal-oxide semiconductor field effect transistors couple instantaneous measurement with high accuracy. However, they only have a limited measurement lifetime because they undergo permanent degradation due to x-ray beam exposure. A field effect transistor based on carbon nanotubes (CNTs), however, overcomes this drawback of permanent degradation, because it can be reset into its starting state after being exposed to the x-ray beam. In this work the CNTs were deposited using a dielectrophoresis method on SiO2 coated p-type (boron-doped) Si substrates. For the prepared devices a best gate voltage shift of 244 V Gy-1 and a source-drain current sensitivity of 382 nA Gy-1 were achieved. These values are larger than those reached by the currently used MOSFET based devices.

  7. The Hard X-ray Emission of Cen A

    CERN Document Server

    Beckmann, V; Lubinski, P; Soldi, S; Terrier, R

    2011-01-01

    The radio galaxy Cen A has been detected all the way up to the TeV energy range. This raises the question about the dominant emission mechanisms in the high-energy domain. Spectral analysis allows us to put constraints on the possible emission processes. Here we study the hard X-ray emission as measured by INTEGRAL in the 3-1000 keV energy range, in order to distinguish between a thermal and non-thermal inverse Compton process. The hard X-ray spectrum of Cen A shows a significant cut-off at energies Ec = 434 (+106 -73) keV with an underlying power law of photon index 1.73 +- 0.02. A more physical model of thermal Comptonisation (compPS) gives a plasma temperature of kT = 206+-62 keV within the optically thin corona with Compton parameter y = 0.42 (+0.09 -0.06). The reflection component is significant at the 1.9 sigma level with R = 0.12 (+0.09 -0.10), and a reflection strength R>0.3 can be excluded on a 3 sigma level. Time resolved spectral studies show that the flux, absorption, and spectral slope varied in ...

  8. Hard X-rays from SN 1993J

    Science.gov (United States)

    Leising, M. D.; Kurfess, J. D.; Clayton, D. D.; Grabelsky, D. A.; Grove, J. E.; Johnson, W. N.; Jung, G. V.; Kinzer, R. L.; Kroeger, R. A.; Purcell, W. R.

    1994-01-01

    The Oriented Scintillation Spectrometer Experiment (OSSE) on the Compton Observatory observed SN 1993J during three intervals centered approximately 12, 30, and 108 days after its outburst. Hard X-ray emission was detected in the first two of these intervals. No emission was seen in the third observation or in two earlier observations in 1991 and 1992. The coincidence of the observed excess with the outburst of SN 1993J and the consistency of the spectra and time evolution with those seen at lower energies by ROSAT and ASCA (Astro-D) argue that the observed emission is indeed from SN 1993J. It is probably due to the interaction of the fast supernova ejecta with circumstellar material. The luminosity, 5 x 10(exp 40) ergs/sec (50-150 keV) in the first interval, is significantly larger than predicted. Extrapolating the spectrum to a few keV accounts for most or all of the observed emission at low energy. The observed high temperature, 10(exp 9) K, is easily obtained in the shocked circumstellar matter, but a surprisingly high density is required there to give the observed luminosity, and little or no additional X-ray emission from denser shocked supernova ejecta is allowed. The hard emission might also be explained in terms of the shocked supernova ejecta itself with unexpectedly high temperature.

  9. X-Ray Ccds for Space Applications: Calibration, Radiation Hardness, and Use for Measuring the Spectrum of the Cosmic X-Ray Background

    Science.gov (United States)

    Gendreau, Keith Charles

    1995-01-01

    This thesis has two distinct components. One concerns the physics of the high energy resolution X-ray charge coupled devices (CCD) detectors used to measure the cosmic X-ray background (XRB) spectrum. The other involves the measurements and analysis of the XRB spectrum and instrumental background with these detectors on board the advanced satellite for cosmology and astrophysics (ASCA). The XRB has a soft component and a hard component divided at ~2 keV. The hard component is extremely isotropic, suggesting a cosmological origin. The soft component is extremely anisotropic. A galactic component most likely dominates the soft band with X-ray line emission due to a hot plasma surrounding the solar system. ASCA is one of the first of a class of missions designed to overlap the hard and soft X-ray bands. The X-ray CCD's energy resolution allows us to spectrally separate the galactic and cosmological components. Also, the resolution offers the ability to test several specific cosmological models which would make up the XRB. I have concentrated on models for the XRB origin which include active galactic nuclei (AGN) as principal components. I use ASCA data to put spectral constraints on the AGN synthesis model for the XRB. The instrumental portion of this thesis concerns the development and calibration of the X-ray CCDs. I designed, built and operated an X-ray calibration facility for these detectors. It makes use of a reflection grating spectrometer to measure absolute detection efficiency, characteristic absorption edge strengths, and spectral redistribution in the CCD response function. Part of my thesis research includes a study of radiation damage mechanisms in CCDs. This work revealed radiation damage-induced degradation in the spectral response to X-rays. It also uncovered systematic effects which affect both data analysis and CCD design. I have developed a model involving trap energy levels in the CCD band gap structure. These traps reduce the efficiency in which

  10. Development of a stacked detector system for the x-ray range and its possible applications

    Science.gov (United States)

    Maier, Daniel; Limousin, Olivier; Meuris, Aline; Pürckhauer, Sabina; Santangelo, Andrea; Schanz, Thomas; Tenzer, Christoph

    2014-07-01

    We have constructed a stacked detector system operating in the X-ray range from 0.5 keV to 250 keV that consists of a Si-based 64×64 DePFET-Matrix in front of a CdTe hybrid detector called Caliste-64. The setup is operated under laboratory conditions that approximate the expected environment of a space-borne observatory. The DePFET detector is an active pixel matrix that provides high count-rate capabilities with a near Fanolimited spectral resolution at energies up to 15 keV. The Caliste-64 hard X-ray camera consists of a 1mm thick CdTe crystal combined with very compact integrated readout electronics, constituting a high performance spectro-imager with event-triggered time-tagging capability in the energy range between 2 keV and 200 keV. In this combined geometry the DePFET detector works as the Low Energy Detector (LED) while the Caliste-64 - as the High Energy Detector (HED) - detects predominantly the high energetic photons that have passed the LED. In addition to the individual optimization of both detectors, we use the setup to test and optimize the performance of the combined detector system. Side-effects like X-ray fluorescence photons, electrical crosstalk, and mutual heating have negative impacts on the data quality and will be investigated. Besides the primary application as a combined imaging detector system with high sensitivity across a broad energy range, additional applications become feasible. Via the analysis of coincident events in both detectors we can estimate the capabilities of the setup to be used as a Compton camera and as an X-ray polarimeter - both desirable functionalities for use in the lab as well as for future X-ray missions.

  11. Polymer Compund Refractive Lenses for Hard X-ray Nanofocusing

    OpenAIRE

    Krywka, Christina; Last, Arndt; Marschall, Felix; Markus, Otto; Georgi, Sebastian; Mueller, Martin; Mohr, Jürgen

    2016-01-01

    Compound refractive lenses fabricated out of SU-8 negative photoresist have been used to generate a nanofocused, i.e. sub-μm sized X-ray focal spot at an X-ray nanodiffraction setup. X-ray microscopy and X-ray diffraction techniques have conceptually different demands on nanofocusing optical elements and so with the application of X-ray nanodiffraction in mind, this paper presents the results of an initial characterization of polymer lenses used as primary focusin...

  12. Recent developments in X-ray imaging detectors

    CERN Document Server

    Moy, J P

    2000-01-01

    The replacement of the radiographic film in medical imaging has been the driving force in X-ray imaging developments. It requires a approx 40 cm wide detector to cover all examinations, an equivalent noise level of 1-5 X-ray quanta per pixel, and spatial resolution in the range 100-150 mu m. The need for entirely electronic imaging equipments has fostered the development of many X-ray detectors, most of them based on an array of amorphous silicon pixels, which is the only technology capable to achieve such large areas. Essentially, two concepts have been implemented: - intermediate conversion of X-rays to light by a scintillator, detected by an array of light sensitive pixels, comprising a photodiode and a switching device, either a TFT or a diode. - conversion into electron-hole pairs in a photoconductor, collected by an array of electrodes and switches. In both cases, charge amplifiers read the generated charges line by line. Scintillator and photoconductor-based systems are now close to production. They ac...

  13. Hard X-ray-induced optical luminescence via biomolecule-directed metal clusters.

    Science.gov (United States)

    Osakada, Yasuko; Pratx, Guillem; Sun, Conroy; Sakamoto, Masanori; Ahmad, Moiz; Volotskova, Olga; Ong, Qunxiang; Teranishi, Toshiharu; Harada, Yoshie; Xing, Lei; Cui, Bianxiao

    2014-04-07

    Here, we demonstrate that biomolecule-directed metal clusters are applicable in the study of hard X-ray excited optical luminescence, promising a new direction in the development of novel X-ray-activated imaging probes.

  14. NuSTAR Hard X-ray Survey of the Galactic Center Region II: X-ray Point Sources

    CERN Document Server

    Hong, JaeSub; Hailey, Charles J; Nynka, Melania; Zhang, Shuo; Gotthelf, Eric; Fornasini, Francesca M; Krivonos, Roman; Bauer, Franz; Perez, Kerstin; Tomsick, John A; Bodaghee, Arash; Chiu, Jeng-Lun; Clavel, Maïca; Stern, Daniel; Grindlay, Jonathan E; Alexander, David M; Aramaki, Tsuguo; Baganoff, Frederick K; Barret, David; Barrière, Nicolas; Boggs, Steven E; Canipe, Alicia M; Christensen, Finn E; Craig, William W; Desai, Meera A; Forster, Karl; Giommi, Paolo; Grefenstette, Brian W; Harrison, Fiona A; Hong, Dooran; Hornstrup, Allan; Kitaguchi, Takao; Koglin, Jason E; Madsen, Kristen K; Mao, Peter H; Miyasaka, Hiromasa; Perri, Matteo; Pivovaroff, Michael J; Puccetti, Simonetta; Rana, Vikram; Westergaard, Niels J; Zhang, William W; Zoglauer, Andreas

    2016-01-01

    We present the first survey results of hard X-ray point sources in the Galactic Center (GC) region by NuSTAR. We have discovered 70 hard (3-79 keV) X-ray point sources in a 0.6 deg^2 region around Sgr A* with a total exposure of 1.7 Ms, and 7 sources in the Sgr B2 field with 300 ks. We identify clear Chandra counterparts for 58 NuSTAR sources and assign candidate counterparts for the remaining 19. The NuSTAR survey reaches X-ray luminosities of ~4 x and ~8 x 10^32 erg s^-1 at the GC (8 kpc) in the 3-10 and 10-40 keV bands, respectively. The source list includes three persistent luminous X-ray binaries and the likely run-away pulsar called the Cannonball. New source-detection significance maps reveal a cluster of hard (>10 keV) X-ray sources near the Sgr A diffuse complex with no clear soft X-ray counterparts. The severe extinction observed in the Chandra spectra indicates that all the NuSTAR sources are in the central bulge or are of extragalactic origin. Spectral analysis of relatively bright NuSTAR sources ...

  15. Application of an EMCCD Camera for Calibration of Hard X-Ray Telescopes

    DEFF Research Database (Denmark)

    Vogel, Julia K.; Pivovaroff, M. J.; Nagarkar, V. V.

    2012-01-01

    Recent technological innovations now make it feasible to construct hard x-ray telescopes for space-based astronomical missions. Focusing optics are capable of improving the sensitivity in the energy range above 10 keV by orders of magnitude compared to previously used instruments. The last decade...... (EMCCDs) [4] are highly suitable detectors for ground-based calibrations. Their chip can be optically coupled to a microcolumnar CsI(Tl) scintillator [5] via a fiberoptic taper. Not only does this device exhibit low noise and high spatial resolution inherent to CCDs, but the EMCCD is also able to handle...... high frame rates due to its controllable internal gain. Additionally, thick CsI(Tl) yields high detection efficiency for x-rays [6]. This type of detector has already proven to be a unique device very suitable for calibrations in astrophysics: such a camera was used to support the characterization...

  16. Superconducting tunnel junction detectors for soft x-ray astrophysics

    Science.gov (United States)

    Verhoeve, P.; Hijmering, R. A.; Martin, D. D. E.; Jerjen, I.; Peacock, A.; Venn, R.

    2006-06-01

    The requirement on energy resolution for detectors in future X-ray satelite missions such as XEUS (X-ray Evolving Universe Spectroscopy mission) is 80%. In addition, the requirements for field of view and angular resolution demand a detector array of typically 150x150 micron sized pixels in a 30x30 pixel format. DROIDs (Distributed Read Out Imaging Devices), consisting of a superconducting absorber strip with superconducting tunnel junctions (STJs) as read-out devices on either end, can fulfill these requirements. The amplitudes of the two signals from the STJs provide information on the absorption position and the energy of the incoming photon in the absorber. In this paper we present the development status of Ta/Al 1-D DROIDs, as well as the the short term development program that should result in a full size XEUS array.

  17. Single-Grid-Pair Fourier Telescope for Imaging in Hard-X Rays and gamma Rays

    Science.gov (United States)

    Campbell, Jonathan

    2008-01-01

    This instrument, a proposed Fourier telescope for imaging in hard-x rays and gamma rays, would contain only one pair of grids made of an appropriate radiation-absorpting/ scattering material, in contradistinction to multiple pairs of such as grids in prior Fourier x- and gamma-ray telescopes. This instrument would also include a relatively coarse gridlike image detector appropriate to the radiant flux to be imaged. Notwithstanding the smaller number of grids and the relative coarseness of the imaging detector, the images produced by the proposed instrument would be of higher quality.

  18. Large area x-ray detectors for cargo radiography

    Science.gov (United States)

    Bueno, C.; Albagli, D.; Bendahan, J.; Castleberry, D.; Gordon, C.; Hopkins, F.; Ross, W.

    2007-04-01

    Large area x-ray detectors based on phosphors coupled to flat panel amorphous silicon diode technology offer significant advances for cargo radiologic imaging. Flat panel area detectors provide large object coverage offering high throughput inspections to meet the high flow rate of container commerce. These detectors provide excellent spatial resolution when needed, and enhanced SNR through low noise electronics. If the resolution is reduced through pixel binning, further advances in SNR are achievable. Extended exposure imaging and frame averaging enables improved x-ray penetration of ultra-thick objects, or "select-your-own" contrast sensitivity at a rate many times faster than LDAs. The areal coverage of flat panel technology provides inherent volumetric imaging with the appropriate scanning methods. Flat panel area detectors have flexible designs in terms of electronic control, scintillator selection, pixel pitch, and frame rates. Their cost is becoming more competitive as production ramps up for the healthcare, nondestructive testing (NDT), and homeland protection industries. Typically used medical and industrial polycrystalline phosphor materials such as Gd2O2S:Tb (GOS) can be applied to megavolt applications if the phosphor layer is sufficiently thick to enhance x-ray absorption, and if a metal radiator is used to augment the quantum detection efficiency and reduce x-ray scatter. Phosphor layers ranging from 0.2-mm to 1-mm can be "sandwiched" between amorphous silicon flat panel diode arrays and metal radiators. Metal plates consisting of W, Pb or Cu, with thicknesses ranging from 0.25-mm to well over 1-mm can be used by covering the entire area of the phosphor plate. In some combinations of high density metal and phosphor layers, the metal plate provides an intensification of 25% in signal due to electron emission from the plate and subsequent excitation within the phosphor material. This further improves the SNR of the system.

  19. The color of X-rays Spectral X-ray computed tomography using energy sensitive pixel detectors

    CERN Document Server

    Schioppa, Enrico Junior

    Energy sensitive X-ray imaging detectors are produced by connecting a semiconductor sensor to a spectroscopic pixel readout chip. In this thesis, the applicability of such detectors to X-ray Computed Tomography (CT) is studied. A prototype Medipix based silicon detector is calibrated using X-ray fluorescence. The charge transport properties of the sensor are characterized using a high energy beam of charged particles at the Super Proton Synchrotron (SPS) at the European Center for Nuclear Research (CERN). Monochromatic X-rays at the European Synchrotron Radiation Facility (ESRF) are used to determined the energy response function. These data are used to implement a physics-based CT projection operator that accounts for the transmission of the source spectrum through the sample and detector effects. Based on this projection operator, an iterative spectral CT reconstruction algorithm is developed by extending an Ordered Subset Expectation Maximization (OSEM) method. Subsequently, a maximum likelihood based algo...

  20. FY06 LDRD Final Report Next-generation x-ray optics: focusing hard x-rays

    Energy Technology Data Exchange (ETDEWEB)

    Pivovaroff, M; Soufli, R

    2007-03-01

    The original goal of our research was to open up a new class of scientific experiments by increasing the power of newly available x-ray sources by orders of magnitude. This was accomplished by developing a new generation of x-ray optics, based on hard x-ray (10-200 keV) reflective and diffractive focusing elements. The optical systems we envision begin with a core reflective optic, which has the ability to capture and concentrate x-rays across a wide range of energies and angles band, combined with diffractive optics, based on large-scale multilayer structures, that will further enhance the spatial, spectral and temporal resolving power of the system. Enabling technologies developed at LLNL such as precise mounting of thermally formed substrates, smoothing techniques and multilayer films of ultra-high reflectance and precision were crucial in the development and demonstration of our research objectives. Highlights of this phase of the project include: the design and fabrication of a concentrator optic for the Pleiades Thomson X-ray source located at LLNL, smoothing of glass substrates through application of polyimide films, and the design, fabrication and testing of novel volume multilayers structures. Part of our research into substrate smooth led to the development of a new technique (patent pending) to construct high-quality, inexpensive x-ray optics. This innovation resulted in LLNL constructing a x-ray optic for the CERN Axion Solar Telescope (CAST) and allowed LLNL to join the international experiment.

  1. ISO investigates the nature of extremely-red hard X-ray sources responsible for the X-ray background

    CERN Document Server

    Franceschini, A; Césarsky, C J; Elbaz, D; Flores, H; Granato, G L; Franceschini, Alberto; Fadda, Dario; Cesarsky, Catherine; Elbaz, David; Flores, Hector; Granato, Gian Luigi

    2001-01-01

    We analyse very deep X-ray and mid-IR surveys in common areas of the Lockman Hole and the HDF North to study the sources of the X-ray background (XRB) and to test the standard obscured accretion paradigm. We detect with ISO a rich population of X-ray luminous sources with red optical colours, including a fraction identified with Extremely Red Objects (R-K > 5) and galaxies with SEDs typical of normal massive ellipticals or spirals at z ~ 1. The high 0.5-10 keV X-ray luminosities of these objects (1E43-1E45 erg/s) indicate that the ultimate energy source is gravitational accretion, while the X-ray to IR flux ratios and the X-ray spectral hardness show evidence of photoelectric absorption at low X-ray energies. An important hint on the physics comes from the mid-IR data at 6.7 and 15 um, well reproduced by model spectra of completely obscured quasars under standard assumptions and l.o.s. optical depths tau ~ 30-40. Other predictions of the standard XRB picture, like the distributions of intrinsic bolometric lum...

  2. Development of a fast multi-line x-ray CT detector for NDT

    Science.gov (United States)

    Hofmann, T.; Nachtrab, F.; Schlechter, T.; Neubauer, H.; Mühlbauer, J.; Schröpfer, S.; Ernst, J.; Firsching, M.; Schweiger, T.; Oberst, M.; Meyer, A.; Uhlmann, N.

    2015-04-01

    Typical X-ray detectors for non-destructive testing (NDT) are line detectors or area detectors, like e.g. flat panel detectors. Multi-line detectors are currently only available in medical Computed Tomography (CT) scanners. Compared to flat panel detectors, line and multi-line detectors can achieve much higher frame rates. This allows time-resolved 3D CT scans of an object under investigation. Also, an improved image quality can be achieved due to reduced scattered radiation from object and detector themselves. Another benefit of line and multi-line detectors is that very wide detectors can be assembled easily, while flat panel detectors are usually limited to an imaging field with a size of approx. 40 × 40 cm2 at maximum. The big disadvantage of line detectors is the limited number of object slices that can be scanned simultaneously. This leads to long scan times for large objects. Volume scans with a multi-line detector are much faster, but with almost similar image quality. Due to the promising properties of multi-line detectors their application outside of medical CT would also be very interesting for NDT. However, medical CT multi-line detectors are optimized for the scanning of human bodies. Many non-medical applications require higher spatial resolutions and/or higher X-ray energies. For those non-medical applications we are developing a fast multi-line X-ray detector.In the scope of this work, we present the current state of the development of the novel detector, which includes several outstanding properties like an adjustable curved design for variable focus-detector-distances, conserving nearly uniform perpendicular irradiation over the entire detector width. Basis of the detector is a specifically designed, radiation hard CMOS imaging sensor with a pixel pitch of 200 μ m. Each pixel has an automatic in-pixel gain adjustment, which allows for both: a very high sensitivity and a wide dynamic range. The final detector is planned to have 256 lines of

  3. Hard x-ray single crystal bi-mirror.

    Science.gov (United States)

    Lyubomirskiy, M; Snigireva, I; Kuznetsov, S; Yunkin, V; Snigirev, A

    2015-05-15

    We report a novel hard x-ray interferometer consisting of two parallel channels manufactured in a single Si crystal by means of microfabrication technology. The sidewall surfaces of the channels, similar to mirrors, scatter at very small incident angles, acting equivalently to narrow micrometer size slits as in the Young double-slit interferometer. Experimental tests of the interferometer were performed at the ESRF ID06 beamline in the energy range from 12 to 16 keV. The interference patterns at different grazing incidence angles were recorded in the near- and far-field. Evaluation of the influence of the channel surface roughness on the visibility of interference fringes was performed. The proposed interferometer design allows the arrangement of mirrors at different split distances.

  4. A new hard X-ray transient discovered by INTEGRAL

    DEFF Research Database (Denmark)

    Gibaud, L.; Bazzano, A.; Bozzo, E.

    2011-01-01

    INTEGRAL discovered a new hard X-ray transient, IGR J17498-2921, during the observations performed from 2011-08-11 22:45 to 2011-08-12 05:54 UTC. The source is detected in the IBIS/ISGRI mosaic at a preliminary significance level of 11 and 9 sigma in the 20-40 keV and 40-80 keV energy bands......-law with photon index 1.9+/-0.4 (90% c.l.). The estimated 20-100 keV flux from the spectral fit is ~3.4e-10 erg/s/cm2. Unfortunately, IGR J17498-2921 was located at the border of the JEM-X field of view (FOV) and thus we can not report yet on its detection at low energy (2-25 keV). Further INTEGRAL observations...

  5. High spatial resolution hard X-ray microscope using X-ray refractive lens and phase contrast imaging experiments

    CERN Document Server

    Kohmura, Y; Takeuchi, A; Takano, H; Suzuki, Y; Ishikawa, T; Ohigashi, T; Yokosuka, H

    2001-01-01

    A high spatial resolution X-ray microscope was constructed using an X-ray refractive lens as an objective. The spatial resolution was tested using 18 keV X-ray. A 0.4 mu m line and 0.4 mu m space tantalum test pattern was successfully resolved. Using the similar setup with the addition of a phase plate, a Zernike type phase-contrast microscopy experiment was carried out for the phase retrieval of the samples. Two-dimensional phase-contrast images were successfully taken for the first time in the hard X-ray region. Images of a gold mesh sample were analyzed and the validity of this method was indicated. An improvement of the lens, however, is required for the precise phase retrieval of the samples.

  6. Quality control measurements for digital x-ray detectors.

    Science.gov (United States)

    Marshall, N W; Mackenzie, A; Honey, I D

    2011-02-21

    This paper describes a digital radiography (DR) quality control protocol for DR detectors from the forthcoming report from the Institute of Physics and Engineering in Medicine (IPEM). The protocol was applied to a group of six identical caesium iodide (CsI) digital x-ray detectors to assess reproducibility of methods, while four further detectors were assessed to examine the wider applicability. Twelve images with minimal spatial frequency processing are required, from which the detector response, lag, modulation transfer function (MTF), normalized noise power spectrum (NNPS) and threshold contrast-detail (c-d) detectability are calculated. The x-ray spectrum used was 70 kV and 1 mm added copper filtration, with a target detector air kerma of 2.5 µGy for the NNPS and c-d results. In order to compare detector performance with previous imaging technology, c-d data from four screen/film systems were also acquired, at a target optical density of 1.5 and an average detector air kerma of 2.56 µGy. The DR detector images were typically acquired in 20 min, with a further 45 min required for image transfer and analysis. The average spatial frequency for the 50% point of the MTF for six identical detectors was 1.29 mm(-1) ± 0.05 (3.9% coefficient of variation (cov)). The air kerma set for the six systems was 2.57 µGy ± 0.13 (5.0% cov) and the NNPS at this air kerma was 1.42 × 10(-5) mm(2) (6.5% cov). The detective quantum efficiency (DQE) measured for the six identical detectors was 0.60 at 0.5 mm(-1), with a maximum cov of 10% at 2.9 mm(-1), while the average DQE was 0.56 at 0.5 mm(-1) for three CsI detectors from three different manufacturers. Comparable c-d performance was found for these detectors (5.9% cov) with an average threshold contrast of 0.46% for 11 mm circular discs. The average threshold contrast for the S/F systems was 0.70% at 11 mm, indicating superior imaging performance for the digital systems. The protocol was found to be quick, reproducible and

  7. Two-dimensional position-sensitive gaseous detectors for high-resolution neutron and X-ray diffraction

    CERN Document Server

    Marmotti, M; Kampmann, R

    2002-01-01

    Two-dimensional position-sensitive gaseous detectors have been developed at the Geesthacht Neutron Facility (GeNF) for high-resolution neutron and X-ray diffractometry. They are multi-wire proportional counters with delay-line readout and sensitive areas of 300 mm x 300 mm or 500 mm x 500 mm. For detecting X-rays, neutrons and hard X-rays the counters are filled with Ar/CO sub 2 , sup 3 He/CF sub 4 and Xe/CO sub 2 , respectively. One neutron detector is used at the ARES diffractometer at GKSS, which is dedicated to the analysis of residual stresses. Further ones are used for analysing textures and residual stresses at the hard-X-ray beamline PETRA-2 at HASYLAB, and one detector is being developed for the neutron reflectometer REFSANS at the research reactor FRM-II in Munich, Germany. (orig.)

  8. Development of CZT detectors for x-ray and gamma-ray astronomy

    Science.gov (United States)

    Lee, Kuen; Martin, J. W.; Garson, A., III; Guo, Q.; Matteson, J.; Groza, M.; Beilicke, M.; Burger, A.; de Geronimo, G.; Krawczynski, H.

    2011-09-01

    Cadmium Zinc Telluride (CZT) is the detector material of choice for the detection of X-rays in the 10 keV-1MeV energy band with excellent spatial and energy resolutions and without cryogenic cooling. In this contribution, we report on recent results of the CZT detector development program and several astrophysical experiments which make use of CZT detectors. In the first part of the paper, we discuss the performance of pixel and cross-strip CZT detectors read out with an ASIC developed at the Brookhaven National Laboratory. Our pixel detectors achieve some of the best energy resolutions reported in the literature. Cross-strip detectors are found to give an inferior performance and we investigate the reason for this performance difference. We also present results from a precision measurement of the effect of a steering grid on multi-pixel events obtained with a 200 micrometer collimator. In the second part of the paper, we describe the design and performance of the hard X-ray polarimeter X-Calibur. The polarimeter uses a 14 cm long scintillator scatterer, surrounded by an assembly of 32 2-5 mm thick CZT detectors. We discuss the sensitivity of the polarimeter to measure the linear polarization of 10 keV-80 keV X-rays on short and long balloon flights and results from testing the polarimeter in the laboratory.

  9. High resolution, multiple-energy linear sweep detector for x-ray imaging

    Science.gov (United States)

    Perez-Mendez, V.; Goodman, C.A.

    1996-08-20

    Apparatus is disclosed for generating plural electrical signals in a single scan in response to incident X-rays received from an object. Each electrical signal represents an image of the object at a different range of energies of the incident X-rays. The apparatus comprises a first X-ray detector, a second X-ray detector stacked upstream of the first X-ray detector, and an X-ray absorber stacked upstream of the first X-ray detector. The X-ray absorber provides an energy-dependent absorption of the incident X-rays before they are incident at the first X-ray detector, but provides no absorption of the incident X-rays before they are incident at the second X-ray detector. The first X-ray detector includes a linear array of first pixels, each of which produces an electrical output in response to the incident X-rays in a first range of energies. The first X-ray detector also includes a circuit that generates a first electrical signal in response to the electrical output of each of the first pixels. The second X-ray detector includes a linear array of second pixels, each of which produces an electrical output in response to the incident X-rays in a second range of energies, broader than the first range of energies. The second X-ray detector also includes a circuit that generates a second electrical signal in response to the electrical output of each of the second pixels. 12 figs.

  10. The protoMIRAX Hard X-ray Imaging Balloon Experiment

    CERN Document Server

    Braga, João; Avila, Manuel A C; Penacchioni, Ana V; Sacahui, J Rodrigo; Santiago, Valdivino A de; Mattiello-Francisco, Fátima; Strauss, Cesar; Fialho, Márcio A A

    2015-01-01

    The protoMIRAX hard X-ray imaging telescope is a balloon-borne experiment developed as a pathfinder for the MIRAX satellite mission. The experiment consists essentially in a coded-aperture hard X-ray (30-200 keV) imager with a square array (13$\\times$13) of 2mm-thick planar CZT detectors with a total area of 169 cm$^2$. The total, fully-coded field-of-view is $21^{\\circ}\\times 21^{\\circ}$ and the angular resolution is 1$^{\\circ}$43'. In this paper we describe the protoMIRAX instrument and all the subsystems of its balloon gondola, and we show simulated results of the instrument performance. The main objective of protoMIRAX is to carry out imaging spectroscopy of selected bright sources to demonstrate the performance of a prototype of the MIRAX hard X-ray imager. Detailed background and imaging simulations have been performed for protoMIRAX balloon flights. The 3$\\sigma$ sensitivity for the 30-200 keV range is ~1.9 $\\times$ 10$^{-5}$ photons cm$^{-2}$ s$^{-1}$ for an integration time of 8 hs at an atmospheric ...

  11. Diagnostics of underwater electrical wire explosion through a time- and space-resolved hard x-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Sheftman, D.; Shafer, D.; Efimov, S.; Gruzinsky, K.; Gleizer, S.; Krasik, Ya. E. [Physics Department, Technion, Haifa 32000 (Israel)

    2012-10-15

    A time- and space-resolved hard x-ray source was developed as a diagnostic tool for imaging underwater exploding wires. A {approx}4 ns width pulse of hard x-rays with energies of up to 100 keV was obtained from the discharge in a vacuum diode consisting of point-shaped tungsten electrodes. To improve contrast and image quality, an external pulsed magnetic field produced by Helmholtz coils was used. High resolution x-ray images of an underwater exploding wire were obtained using a sensitive x-ray CCD detector, and were compared to optical fast framing images. Future developments and application of this diagnostic technique are discussed.

  12. Matrix-addressed x-ray detector arrays

    Science.gov (United States)

    Street, Robert A.; Apte, Raj B.; Boyce, James B.; Ho, Jackson; Lau, Rachel; Lemmi, Francesco; Lu, Jeng-Ping; Mulato, Marcelo; Ready, Steve E.; Van Schuylenbergh, Koenraad

    2000-11-01

    Amorphous silicon (a-Si:H) technology has created a successful manufacturing business for large area active matrix arrays, of which liquid crystal displays (AMLCD) are the best known, and image sensors are an emerging technology for medical x-ray imaging. The large area, flat plate, format is the key feature of the technology that sets it apart from other digital imaging approaches. The principal requirements for medical imaging are sensitivity and high dynamic range. A-Si:H detectors have already proved to perform at least as well as x-ray film for radiographic applications and comparable to image intensifiers for fluoroscopy. There are several approaches to improving the performance of the image sensors is order to achieve higher sensitivity and higher spatial resolution. This paper describes some of these approaches.

  13. The origin of the hard X-ray tail in neutron-star X-ray binaries

    Science.gov (United States)

    Reig, P.; Kylafis, N.

    2016-06-01

    Context. Neutron star X-ray binaries emit a compact, optically thick, relativistic radio jet during low-luminosity, usually hard states, as Galactic black-hole X-ray binaries do. When radio emission is bright, a hard power-law tail without evidence for an exponential cutoff is observed in most systems. Aims: We have developed a jet model that explains many spectral and timing properties of black-hole binaries in the states where a jet is present. Our goal is to investigate whether our jet model can reproduce the hard tail, with the correct range of photon index and the absence of a high-energy cutoff, in neutron-star X-ray binaries. Methods: We performed Monte Carlo simulations of the Compton upscattering of soft, accretion-disk or boundary layer photons in the jet and computed the emergent energy spectra, as well as the time lag of hard photons with respect to softer ones as a function of Fourier frequency. We fit the energy spectra with a power law modified by an exponential cutoff at high energy. Results: We demonstrate that our jet model naturally explains the observed power-law distribution with photon index in the range 1.8-3. With an appropriate choice of the parameters, the cutoff expected from Comptonization is shifted to energies above ~300 keV, producing a pure power law without any evidence for a rollover, in agreement with the observations. Conclusions: Our results reinforce the idea that the link between the outflow (jet) and inflow (disk) in X-ray binaries does not depend on the nature of the compact object, but on the process of accretion. Furthermore, we address the differences between jets in black-hole and neutron-star X-ray binaries and predict that the break frequency in the spectral energy distribution of neutron-star X-ray binaries, as a class, will be lower than that of black-hole binaries.

  14. Design of a radiation hard silicon pixel sensor for X-ray science

    Energy Technology Data Exchange (ETDEWEB)

    Schwandt, Joern

    2014-06-15

    At DESY Hamburg the European X-ray Free-Electron Laser (EuXFEL) is presently under construction. The EuXFEL has unique properties with respect to X-ray energy, instantaneous intensity, pulse length, coherence and number of pulses/sec. These properties of the EuXFEL pose very demanding requirements for imaging detectors. One of the detector systems which is currently under development to meet these challenges is the Adaptive Gain Integrating Pixel Detector, AGIPD. It is a hybrid pixel-detector system with 1024 x 1024 p{sup +} pixels of dimensions 200 μm x 200 μm, made of 16 p{sup +}nn{sup +}- silicon sensors, each with 10.52 cm x 2.56 cm sensitive area and 500 μm thickness. The particular requirements for the AGIPD are a separation between noise and single photons down to energies of 5 keV, more than 10{sup 4} photons per pixel for a pulse duration of less than 100 fs, negligible pile-up at the EuXFEL repetition rate of 4.5 MHz, operation for X-ray doses up to 1 GGy, good efficiency for X-rays with energies between 5 and 20 keV, and minimal inactive regions at the edges. The main challenge in the sensor design is the required radiation tolerance and high operational voltage, which is required to reduce the so-called plasma effect. This requires a specially optimized sensor. The X-ray radiation damage results in a build-up of oxide charges and interface traps which lead to a reduction of the breakdown voltage, increased leakage current, increased interpixel capacitances and charge losses. Extensive TCAD simulations have been performed to understand the impact of X-ray radiation damage on the detector performance and optimize the sensor design. To take radiation damage into account in the simulation, radiation damage parameters have been determined on MOS capacitors and gate-controlled diodes as function of dose. The optimized sensor design was fabricated by SINTEF. Irradiation tests on test structures and sensors show that the sensor design is radiation hard and

  15. kHz femtosecond laser-plasma hard X-ray and fast ion source

    Science.gov (United States)

    Thoss, A.; Korn, G.; Richardson, M. C.; Faubel, M.; Stiel, H.; Voigt, U.; Siders, C. W.; Elsaesser, T.

    2002-04-01

    We describe the first demonstration of a new stable, kHz femtosecond laser-plasma source of hard x-ray continuum and Kα emission using a thin liquid metallic jet target. kHz femtosecond x-ray sources will find many applications in time-resolved x-ray diffraction and microscopy studies. As high intensity lasers become more compact and operate at increasingly high repetition-rates, they require a target configuration that is both repeatable from shot-to-shot and is debris-free. We have solved this requirement with the use of a fine (10-30 μm diameter) liquid metal jet target that provides a pristine, unperturbed filament surface at rates >100 kHz. A number of liquid metal targets are considered. We will show hard x-ray spectra recorded from liquid Ga targets that show the generation of the 9.3 keV and 10.3 keV, Kα and Kβ lines superimposed on a multi-keV Bremsstrahlung continuum. This source was generated by a 50fs duration, 1 kHz, 2W, high intensity Ti:Sapphire laser. We will discuss the extension of this source to higher powers and higher repetition rates, providing harder x-ray emission, with the incorporation of pulse-shaping and other techniques to enhance the x-ray conversion efficiency. Using the same liquid target technology, we have also demonstrated the generation of forward-going sub-MeV protons from a 10 μm liquid water target at 1 kHz repetition rates. kHz sources of high energy ions will find many applications in time-resolved particle interaction studies, as well as lead to the efficient generation of short-lived isotopes for use in nuclear medicine and other applications. The protons were detected with CR-39 track detectors both in the forward and backward directions up to energies of ~500 keV. As the intensity of compact high repetition-rate lasers sources increase, we can expect improvements in the energy, conversion efficiency and directionality to occur. The impact of these developments on a number of fields will be discussed. As compact

  16. Application of an EMCCD Camera for Calibration of Hard X-Ray Telescopes

    DEFF Research Database (Denmark)

    Vogel, Julia K.; Pivovaroff, M. J.; Nagarkar, V. V.

    2012-01-01

    Recent technological innovations now make it feasible to construct hard x-ray telescopes for space-based astronomical missions. Focusing optics are capable of improving the sensitivity in the energy range above 10 keV by orders of magnitude compared to previously used instruments. The last decade...... has seen focusing optics developed for balloon experiments [1] and they will soon be implemented in approved space missions such as the Nuclear Spectroscopic Telescope Array (NuSTAR) [2] and ASTRO-H [3]. The full characterization of x-ray optics for astrophysical and solar imaging missions, including...... measurement of the point spread function (PSF) as well as scattering and reflectivity properties of substrate coatings, requires a very high spatial resolution, high sensitivity, photon counting and energy discriminating, large area detector. Novel back-thinned Electron Multiplying Charge-Coupled Devices...

  17. SuperAGILE: the hard X-ray Imager for the AGILE space mission

    CERN Document Server

    Feroci, M; Soffitta, P; Del Monte, E; Di Persio, G; Donnarumma, I; Evangelista, Y; Frutti, M; Lapshov, I; Lazzarotto, F; Mastropietro, M; Morelli, E; Pacciani, L; Porrovecchio, G; Rapisarda, M; Rubini, A; Tavani, M; Argan, A

    2007-01-01

    SuperAGILE is a coded mask experiment based on silicon microstrip detectors. It operates in the 15-45 keV nominal energy range, providing crossed one-dimensional images of the X-ray sky with an on-axis angular resolution of 6 arcmin, over a field of view in excess of 1 steradian. It was designed as the hard X-ray monitor of the AGILE space mission, a small satellite of the Italian Space Agency devoted to image the gamma-ray sky in the 30 MeV - 50 GeV energy band. The AGILE mission was launched in a low-earth orbit on 23^{rd} April 2007. In this paper we describe the SuperAGILE experiment, its construction and test processes, and its performance before flight, based on the on-ground test and calibrations.

  18. Photoelectric X-ray Polarimetry with Gas Pixel Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bellazzini, Ronaldo; Brez, Alessandro [INFN Pisa Largo B. Pontecorvo 3, I-56127 Pisa (Italy); Costa, Enrico [INAF/IASF Rome Via del Fosso del Cavaliere 100, I-00133 Rome (Italy); Minuti, Massimo [INFN Pisa Largo B. Pontecorvo 3, I-56127 Pisa (Italy); Muleri, Fabio [INAF/IASF Rome Via del Fosso del Cavaliere 100, I-00133 Rome (Italy); Pinchera, Michele [INFN Pisa Largo B. Pontecorvo 3, I-56127 Pisa (Italy); Rubini, Alda; Soffitta, Paolo [INAF/IASF Rome Via del Fosso del Cavaliere 100, I-00133 Rome (Italy); Spandre, Gloria, E-mail: Gloria.Spandre@pi.infn.it [INFN Pisa Largo B. Pontecorvo 3, I-56127 Pisa (Italy)

    2013-08-21

    The Gas Pixel Detector, recently developed and continuously improved by Pisa-INFN in collaboration with IASF-Roma (INAF), can visualize the tracks produced within a low Z gas by photoelectrons of few keV. By reconstructing the impact point and the original direction of the photoelectrons, the GPD can measure the polarization plane of X-Ray photons, while preserving the information on the absorption point, the energy and the time of arrival of individual photons. Applied to X-ray Astrophysics, in the focus of grazing incidence telescopes, it can perform angular and energy resolved polarimetry with a large improvement of sensitivity, when compared with the conventional techniques of Bragg diffraction at 45° and Compton scattering around 90°. This configuration has been the basis of POLARIX and HXMT, two pathfinder missions, and was included in the baseline design of IXO, the very large X-ray telescope under study by NASA, ESA and JAXA. We have recently improved the design of this low energy polarimeter (2–10 keV) by modifying the geometry of the absorption cell to minimize any systematic effect that could leave a residual polarization signal for non-polarized source. We will report on the testing of this new concept.

  19. Optimization of <= 200 um pitch CZT detectors for future high-resolution X-ray instrumentation in astrophysics

    CERN Document Server

    Zajczyk, Anna; Dowkontt, Paul; Guo, Qingzhen; Kislat, Fabian; Krawczynski, Henric; De Geronimo, Gianluigi; Li, Shaorui; Beilicke, Matthias

    2015-01-01

    Cadmium Zinc Telluride and Cadmium Telluride are the detector materials of choice for the detection of X-rays in the X-ray energy band E >= 5keV with excellent spatial and spectral resolution and without cryogenic cooling. Owing to recent breakthroughs in grazing incidence mirror technology, next-generation hard X-ray telescopes will achieve angular resolution between 5 and 10 arc seconds - about an order of magnitude better than that of the NuSTAR hard X-ray telescope. As a consequence, the next generation of X-ray telescopes will require pixelated X-ray detectors with pixels on a grid with a lattice constant of <= 250um. Additional detector requirements include a low energy threshold of less than 5keV and an energy resolution of less than one keV. The science drivers for a high angular-resolution X-ray mission include studies and measurements of black hole spins, the cosmic evolution of super-massive black holes, active galactic nuclei feedback, and the behaviour of matter at very high densities. In this...

  20. Wide Field Hard X-ray Survey Telescope: ProtoEXIST1

    CERN Document Server

    Hong, J; Chammas, N; Allen, B; Copete, A; Said, B; Burke, M; Howell, J; Gauron, T; Baker, R G; Barthelmy, S D; Sheikh, S; Gehrels, N; Cook, W R; Burnham, J A; Harrison, F A; Collins, J; Labov, S; Garson, A; Krawczynski, H

    2007-01-01

    We report our progress on the development of pixellated imaging CZT detector arrays for our first-generation balloon-borne wide-field hard X-ray (20 - 600 keV) telescope, ProtoEXIST1. Our ProtoEXIST program is a pathfinder for the High Energy Telescope (HET) on the Energetic X-ray Imaging Survey telescope (EXIST), a proposed implementation of the Black Hole Finder Probe. ProtoEXIST1 consists of four independent coded-aperture telescopes with close-tiled (~0.4 mm gaps) CZT detectors that preserve their 2.5mm pixel pitch. Multiple shielding/field-of-view configurations are planned to identify optimal geometry for the HET in EXIST. The primary technical challenge in ProtoEXIST is the development of large area, close-tiled modules of imaging CZT detectors (1000 cm2 for ProtoEXIST1), with all readout and control systems for the ASIC readout vertically stacked. We describe the overall telescope configuration of ProtoEXIST1 and review the current development status of the CZT detectors, from individual detector crys...

  1. A camera for imaging hard x-rays from suprathermal electrons during lower hybrid current drive on PBX-M

    Energy Technology Data Exchange (ETDEWEB)

    von Goeler, S.; Kaita, R.; Bernabei, S.; Davis, W.; Fishman, H.; Gettelfinger, G.; Ignat, D.; Roney, P.; Stevens, J.; Stodiek, W. (Princeton Univ., NJ (United States). Plasma Physics Lab.); Jones, S.; Paoletti, F. (Massachusetts Inst. of Tech., Cambridge, MA (United States). Plasma Fusion Center); Petravich, G. (Hungarian Academy of Sciences, Budapest (Hungary). Central Research Inst. for Physics); Rimini,

    1993-05-01

    During lower hybrid current drive (LHCD), suprathermal electrons are generated that emit hard X-ray bremsstrahlung. A pinhole camera has been installed on the PBX-M tokamak that records 128 [times] 128 pixel images of the bremsstrahlung with a 3 ms time resolution. This camera has identified hollow radiation profiles on PBX-M, indicating off-axis current drive. The detector is a 9in. dia. intensifier. A detailed account of the construction of the Hard X-ray Camera, its operation, and its performance is given.

  2. Application of an EMCCD Camera for Calibration of Hard X-Ray Telescopes

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, J K; Pivovaroff, M J; Nagarkar, V V; Kudrolli, H; Madsen, K K; Koglin, J E; Christensen, F E; Brejnholt, N F

    2011-11-08

    Recent technological innovations now make it feasible to construct hard x-ray telescopes for space-based astronomical missions. Focusing optics are capable of improving the sensitivity in the energy range above 10 keV by orders of magnitude compared to previously used instruments. The last decade has seen focusing optics developed for balloon experiments and they will soon be implemented in approved space missions such as the Nuclear Spectroscopic Telescope Array (NuSTAR) and ASTRO-H. The full characterization of x-ray optics for astrophysical and solar imaging missions, including measurement of the point spread function (PSF) as well as scattering and reflectivity properties of substrate coatings, requires a very high spatial resolution, high sensitivity, photon counting and energy discriminating, large area detector. Novel back-thinned Electron Multiplying Charge-Coupled Devices (EMCCDs) are highly suitable detectors for ground-based calibrations. Their chip can be optically coupled to a microcolumnar CsI(Tl) scintillator via a fiberoptic taper. Not only does this device exhibit low noise and high spatial resolution inherent to CCDs, but the EMCCD is also able to handle high frame rates due to its controllable internal gain. Additionally, thick CsI(Tl) yields high detection efficiency for x-rays. This type of detector has already proven to be a unique device very suitable for calibrations in astrophysics: such a camera was used to support the characterization of the performance for all NuSTAR optics. Further optimization will enable similar cameras to be improved and used to calibrate x-ray telescopes for future space missions. In this paper, we discuss the advantages of using an EMCCD to calibrate hard x-ray optics. We will illustrate the promising features of this detector solution using examples of data obtained during the ground calibration of the NuSTAR telescopes performed at Columbia University during 2010/2011. Finally, we give an outlook on ongoing

  3. Optimization of the Design of the Hard X-ray Polarimeter X-Calibur

    CERN Document Server

    Guo, Qingzhen; Garson, Alfred; Kislat, Fabian; Fleming, David; Krawczynski, Henric; 10.1016/j.astropartphys.2012.11.006

    2012-01-01

    We report on the optimization of the hard X-ray polarimeter X-Calibur for a high-altitude balloon-flight in the focal plane of the InFOC{\\mu}S X-ray telescope from Fort Sumner (NM) in Fall 2013. X-Calibur combines a low-Z scintillator slab to Compton-scatter photons with a high-Z Cadmium Zinc Telluride (CZT) detector assembly to photo-absorb the scattered photons. The detector makes use of the fact that polarized photons Compton scatter preferentially perpendicular to the electric field orientation. X-Calibur achieves a high detection efficiency of order unity and reaches a sensitivity close to the best theoretically possible. In this paper, we discuss the optimization of the design of the instrument based on Monte Carlo simulations of polarized and unpolarized X-ray beams and of the most important background components. We calculate the sensitivity of the polarimeter for the upcoming balloon flight from Fort Sumner and for additional longer balloon flights with higher throughput mirrors. We conclude by empha...

  4. Weak hard X-ray emission from broad absorption line quasars: evidence for intrinsic X-ray weakness

    Energy Technology Data Exchange (ETDEWEB)

    Luo, B.; Brandt, W. N.; Scott, A. E. [Department of Astronomy and Astrophysics, 525 Davey Lab, The Pennsylvania State University, University Park, PA 16802 (United States); Alexander, D. M.; Gandhi, P. [Department of Physics, Durham University, South Road, Durham DH1 3LE (United Kingdom); Stern, D. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States); Teng, S. H. [Observational Cosmology Laboratory, NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Arévalo, P.; Bauer, F. E. [Instituto de Astrofísica, Facultad de Física, Pontificia Universidad Católica de Chile, 306, Santiago 22 (Chile); Boggs, S. E.; Craig, W. W. [Space Sciences Laboratory, University of California, Berkeley, CA 94720 (United States); Christensen, F. E. [DTU Space-National Space Institute, Technical University of Denmark, Elektrovej 327, DK-2800 Lyngby (Denmark); Comastri, A. [INAF—Osservatorio Astronomico di Bologna, Via Ranzani 1, I-40127 Bologna (Italy); Farrah, D. [Department of Physics, Virginia Tech, Blacksburg, VA 24061 (United States); Hailey, C. J. [Columbia Astrophysics Laboratory, Columbia University, New York, NY 10027 (United States); Harrison, F. A. [Cahill Center for Astronomy and Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Koss, M. [Institute for Astronomy, Department of Physics, ETH Zurich, Wolfgang-Pauli-Strasse 27, CH-8093 Zurich (Switzerland); Ogle, P. [IPAC, California Institute of Technology, Mail Code 220-6, Pasadena, CA 91125 (United States); Puccetti, S. [ASDC—ASI, Via del Politecnico, I-00133 Roma (Italy); Saez, C. [Department of Astronomy, University of Maryland, College Park, MD 20742 (United States); and others

    2014-10-10

    We report NuSTAR observations of a sample of six X-ray weak broad absorption line (BAL) quasars. These targets, at z = 0.148-1.223, are among the optically brightest and most luminous BAL quasars known at z < 1.3. However, their rest-frame ≈2 keV luminosities are 14 to >330 times weaker than expected for typical quasars. Our results from a pilot NuSTAR study of two low-redshift BAL quasars, a Chandra stacking analysis of a sample of high-redshift BAL quasars, and a NuSTAR spectral analysis of the local BAL quasar Mrk 231 have already suggested the existence of intrinsically X-ray weak BAL quasars, i.e., quasars not emitting X-rays at the level expected from their optical/UV emission. The aim of the current program is to extend the search for such extraordinary objects. Three of the six new targets are weakly detected by NuSTAR with ≲ 45 counts in the 3-24 keV band, and the other three are not detected. The hard X-ray (8-24 keV) weakness observed by NuSTAR requires Compton-thick absorption if these objects have nominal underlying X-ray emission. However, a soft stacked effective photon index (Γ{sub eff} ≈ 1.8) for this sample disfavors Compton-thick absorption in general. The uniform hard X-ray weakness observed by NuSTAR for this and the pilot samples selected with <10 keV weakness also suggests that the X-ray weakness is intrinsic in at least some of the targets. We conclude that the NuSTAR observations have likely discovered a significant population (≳ 33%) of intrinsically X-ray weak objects among the BAL quasars with significantly weak <10 keV emission. We suggest that intrinsically X-ray weak quasars might be preferentially observed as BAL quasars.

  5. First Images from HERO: A Hard-X-Ray Focusing Telescope

    Science.gov (United States)

    Ramsey, Brian D.; Alexander, Cheryl D.; Apple, Jeff A.; Benson, Carl M.; Dietz, Kurtis L.; Elsner, Ronald F.; Engelhaupt, Darell E.; Ghosh, Kajal K.; Kolodziejczak, Jeffery J.; ODell, Stephen L.; Whitaker, Ann F. (Technical Monitor)

    2001-01-01

    We are developing a balloon-borne hard-x-ray telescope that utilizes grazing incidence optics. Termed HERO, for High-Energy Replicated Optics, the instrument will provide unprecented sensitivity in the hard-x-ray region and will achieve milliCrab-level sensitivity in a typical 3-hour balloon-flight observation and 50 microCrab sensitivity on ultra-long-duration flights. A recent proof-of-concept flight, featuring a small number of mirror shells captured the first focused hard-x-ray images of galactic x-ray sources. Full details of the payload, its expected future performance and its recent measurements are provided.

  6. Multilayer on-chip stacked Fresnel zone plates: Hard x-ray fabrication and soft x-ray simulations

    Energy Technology Data Exchange (ETDEWEB)

    Li, Kenan; Wojcik, Michael J.; Ocola, Leonidas E.; Divan, Ralu; Jacobsen, Chris

    2015-11-01

    Fresnel zone plates are widely used as x-ray nanofocusing optics. To achieve high spatial resolution combined with good focusing efficiency, high aspect ratio nanolithography is required, and one way to achieve that is through multiple e-beam lithography writing steps to achieve on-chip stacking. A two-step writing process producing 50 nm finest zone width at a zone thickness of 1.14 µm for possible hard x-ray applications is shown here. The authors also consider in simulations the case of soft x-ray focusing where the zone thickness might exceed the depth of focus. In this case, the authors compare on-chip stacking with, and without, adjustment of zone positions and show that the offset zones lead to improved focusing efficiency. The simulations were carried out using a multislice propagation method employing Hankel transforms.

  7. Hard X-ray and radio observations of Abell 754

    CERN Document Server

    Fusco-Femiano, R; Grandi, S D; Molendi, S; Feretti, L; Giovannini, G; Bacchi, M; Govoni, F

    2003-01-01

    We present a long BeppoSAX observation of Abell 754 that reports a nonthermal excess with respect to the thermal emission at energies greater than ~45 keV. A VLA radio observation at 1.4 GHz definitely confirms the existence of diffuse radio emission in the central region of the cluster, previously suggested by images at 74 and 330 MHz (Kassim et al 2001), and reports additional features. Besides, our observation determines a steeper radio halo spectrum in the 330-1400 MHz frequency range with respect to the spectrum detected at lower frequencies, indicating the presence of a spectral cutoff. The presence of a radio halo in A754, considered the prototype of a merging cluster, reinforces the link between formation of Mpc-scale radio regions and very recent or current merger processes. The radio results combined with the hard X-ray excess detected by BeppoSAX give information on the origin of the electron population responsible for nonthermal phenomena in galaxy clusters. We discuss also the possibility that 26...

  8. Quantitative phase imaging using hard x-rays

    Energy Technology Data Exchange (ETDEWEB)

    Nugent, K.A.; Paganin, D.; Barnea, Z. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Cookson, D. F. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia); Gureyev, T.E. [Melbourne Univ., Parkville, VIC (Australia). School of Physics]|[CSIRO, Clayton, VIC (Australia). Div. of Forestry and Forest Products

    1997-06-01

    The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.

  9. Probing buried layers by photoelectron spectromicroscopy with hard x-ray excitation

    Energy Technology Data Exchange (ETDEWEB)

    Wiemann, C.; Patt, M.; Cramm, S. [Peter Gruenberg Institute (PGI-6) and JARA-FIT, Research Centre Juelich, D-52425 Juelich (Germany); Escher, M.; Merkel, M. [FOCUS GmbH, D-65510 Huenstetten (Germany); Gloskovskii, A. [Institut fuer Anorganische Chemie und Analytische Chemie, Johannes Gutenberg-Universitaet Mainz, D-55128 Mainz (Germany); Thiess, S.; Drube, W. [DESY Photon Science, Deutsches Elektronen-Synchrotron, D-22603 Hamburg (Germany); Schneider, C. M. [Peter Gruenberg Institute (PGI-6) and JARA-FIT, Research Centre Juelich, D-52425 Juelich (Germany); Fakultaet f. Physik and Center for Nanointegration Duisburg-Essen (CENIDE), Universitaet Duisburg-Essen, D-47048 Duisburg (Germany)

    2012-05-28

    We report about a proof-of-principle experiment which explores the perspectives of performing hard x-ray photoemission spectromicroscopy with high lateral resolution. Our results obtained with an energy-filtered photoemission microscope at the PETRA III storage ring facility using hard x-ray excitation up to 6.5 keV photon energy demonstrate that it is possible to obtain selected-area x-ray photoemission spectra from regions less than 500 nm in diameter.

  10. NuSTAR Hard X-ray Survey of the Galactic Center Region I: Hard X-ray Morphology and Spectroscopy of the Diffuse Emission

    CERN Document Server

    Mori, Kaya; Krivonos, Roman; Hong, Jaesub; Ponti, Gabriele; Bauer, Franz; Perez, Kerstin; Nynka, Melania; Zhang, Shuo; Tomsick, John A; Alexander, David M; Baganoff, Frederick K; Barret, Didier; Barriere, Nicolas; Boggs, Steven E; Canipe, Alicia M; Christensen, Finn E; Craig, William W; Forster, Karl; Giommi, Paolo; Grefenstette, Brian W; Grindlay, Jonathan E; Harrison, Fiona A; Hornstrup, Allan; Kitaguchi, Takao; Koglin, Jason E; Luu, Vy; Madsen, Kristen K; Mao, Peter H; Miyasaka, Hiromasa; Perri, Matteo; Pivovaroff, Michael J; Puccetti, Simonetta; Rana, Vikram; Stern, Daniel; Westergaard, Niels J; Zhang, William W; Zoglauer, Andreas

    2015-01-01

    We present the first sub-arcminute images of the Galactic Center above 10 keV, obtained with NuSTAR. NuSTAR resolves the hard X-ray source IGR J17456-2901 into non-thermal X-ray filaments, molecular clouds, point sources and a previously unknown central component of hard X-ray emission (CHXE). NuSTAR detects four non-thermal X-ray filaments, extending the detection of their power-law spectra with $\\Gamma\\sim1.3$-$2.3$ up to ~50 keV. A morphological and spectral study of the filaments suggests that their origin may be heterogeneous, where previous studies suggested a common origin in young pulsar wind nebulae (PWNe). NuSTAR detects non-thermal X-ray continuum emission spatially correlated with the 6.4 keV Fe K$\\alpha$ fluorescence line emission associated with two Sgr A molecular clouds: MC1 and the Bridge. Broad-band X-ray spectral analysis with a Monte-Carlo based X-ray reflection model self-consistently determined their intrinsic column density ($\\sim10^{23}$ cm$^{-2}$), primary X-ray spectra (power-laws wi...

  11. HERO: Program Status and Fist Images from a Balloon-Borne Focusing Hard-X-ray Telescope

    Science.gov (United States)

    Ramsey, B. D.; Alexander, C. D.; Apple, J. A.; Benson, C. M.; Dietz, K. L.; Elsner, R. F.; Engelhaupt. D. E.; Ghosh, K. K.; Kolodziejczak, J. J.; ODell, S. L.; hide

    2001-01-01

    HERO is a balloon payload featuring shallow-graze angle replicated optics for hard-x-ray imaging. When completed, the instrument will offer unprecedented sensitivity in the hard-x-ray region, giving thousands of sources to choose from for detailed study on long flights. A recent proof-of-concept flight captured the first hard-x-ray focused images of the Crab Nebula, Cygnus X-1 and GRS 1915+105. Full details of the HERO program are presented, including the design and performance of the optics, the detectors and the gondola. Results from the recent proving flight are discussed together with expected future performance when the full science payload is completed.

  12. First flight of SMASH, the SwRI Miniature Assembly for Solar Hard X-rays

    Science.gov (United States)

    Caspi, Amir; Laurent, Glenn Thomas; Shoffner, Michael; Higuera Caubilla, David; Meurisse, Jeremie; Smith, Kelly; Shih, Albert Y.; Saint-Hilaire, Pascal; DeForest, Craig; Mansour, Nagi N.; Hathaway, David H.

    2016-05-01

    The SwRI Miniature Assembly for Solar Hard X-rays (SMASH) was successfully flown from Antarctica in January (19-30) 2016, as a piggy-back instrument on the Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) high altitude balloon payload. SMASH is a technological demonstration of a new miniaturized hard X-ray (HXR) detector for use on CubeSats and other small spacecraft, including the proposed CubeSat Imaging X-ray Solar Spectrometer (CubIXSS).HXRs are the observational signatures of energetic processes on the Sun, including plasma heating and particle acceleration. One of the goals of CubIXSS will be to address the question of how plasma is heated during solar flares, including the relationship between thermal plasma and non-thermal particles. SMASH demonstrated the space-borne application of the commercial off-the-shelf Amptek X123-CdTe, a miniature cadmium telluride photon-counting HXR spectrometer. The CdTe detector has a physical area of 25 mm^2 and 1 mm fully-depleted thickness, with a ~100 micron Be window; with on-board thermoelectric cooling and pulse pile-up rejection, it is sensitive to solar photons from ~5 to ~100 keV with ~0.5-1.0 keV FWHM resolution. Photons are accumulated into histogram spectra with customizable energy binning and integration time. With modest resource requirements (~1/8 U, ~200 g, ~2.5 W) and low cost (~$10K), the X123-CdTe is an attractive solution for HXR measurements from budget- and resource-limited platforms such as CubeSats. SMASH flew two identical X123-CdTe detectors for redundancy and increased collecting area; the supporting electronics (power, CPU) were largely build-to-print using the Miniature X-ray Solar Spectrometer (MinXSS) CubeSat design.We review the SMASH mission, design, and detector performance during the 12-day Antarctic flight. We present current progress on our data analysis of observed solar flares, and discuss future applications of the space-qualified X123-CdTe detector, including the CubIXSS mission

  13. Hard X-ray Spectroscopic, Microwave and H-alpha Linear Polarization Studies with Hard X-Ray Observations from HESSI

    Science.gov (United States)

    Kiplinger, Alan L.

    2005-01-01

    The Principal Investigator (P.I.) has been pursuing a three year grant under NASA's Sun-Earth Connection Guest Investigator Program in support of the Ramaty High Energy Solar Spectroscopic Imager (RHESSI). An objective of these efforts is to combine X-ray and other data on solar flares, coronal mass ejections and interplanetary particle events in order to obtain a more comprehensive recognition of signatures, and understanding of interplanetary proton events. Thus, part of these efforts are to investigate if signatures seen in hard X-rays and microwaves can lead to better predictions of interplanetary proton events that can be dangerous to astronauts and spacecraft. The original proposal was written in May, 2000 and it discusses a three-pronged approach for data comparisons with three new types of instrumentation observing at X-ray, microwave and optical wavelengths. The major impetus behind this work and the proposal is that the P.I. discovered a strong correlation between a particular type of hard X-ray signature seen in spectral evolutions and interplanetary proton events (Kiplinger, 1995). The basic signature is that hard X-ray flux peaks either exhibit spectra that soften on their decays (Le. show fewer and fewer high energy X-rays with time) or they harden during decays (i.e. high energy X-rays decay significantly slower that lower energy X-rays). This signature is called progressive hardening. Studies were conducted over an eight-year period of data from the Hard X-Ray Burst Spectrometer (HXRBS) of the Solar maximum mission. Out of the 750 well observed flares studied, 41 flares had major associated proton events. Of these, 29 events were predicted on the basis of progressive hardening for a hit rate of 71%. The 152 largest flares had a hit rate of 82%.

  14. Computational modelling of semiconducting X-ray detectors

    CERN Document Server

    Fowler, R F; Greenough, C S

    2002-01-01

    The design of high-performance semiconductor detectors is dominated by requirements on position and energy resolution and speed of operation. We investigate the contribution that three-dimensional transient device modelling can make to understanding these and the potential for its use in the design cycle. Simulations are performed using the EVEREST software to solve the drift-diffusion equations. Extra functionality has been added to allow the generation of electron-hole pairs by, for example, the absorption of an X-ray. Careful time integration can measure the time of arrival of the charge packet at the collecting well. By time integrating the current arriving in the collecting well the spatial distribution of charge can be determined. A simple analytic theory is developed and compared with simulations of a large pixel detector. Comparisons with simulations of a two pixel device show that the analytic approximation is reasonable if the X-ray is absorbed beyond 100 mu m from the well, but events closer show a...

  15. Hybrid Pixel Detectors for gamma/X-ray imaging

    Science.gov (United States)

    Hatzistratis, D.; Theodoratos, G.; Zografos, V.; Kazas, I.; Loukas, D.; Lambropoulos, C. P.

    2015-09-01

    Hybrid pixel detectors are made by direct converting high-Z semi-insulating single crystalline material coupled to complementary-metal-oxide semiconductor (CMOS) readout electronics. They are attractive because direct conversion exterminates all the problems of spatial localization related to light diffusion, energy resolution, is far superior from the combination of scintillation crystals and photomultipliers and lithography can be used to pattern electrodes with very fine pitch. We are developing 2-D pixel CMOS ASICs, connect them to pixilated CdTe crystals with the flip chip and bump bonding method and characterize the hybrids. We have designed a series of circuits, whose latest member consists of a 50×25 pixel array with 400um pitch and an embedded controller. In every pixel a full spectroscopic channel with time tagging information has been implemented. The detectors are targeting Compton scatter imaging and they can be used for coded aperture imaging too. Hybridization using CMOS can overcome the limit put on pixel circuit complexity by the use of thin film transistors (TFT) in large flat panels. Hybrid active pixel sensors are used in dental imaging and other applications (e.g. industrial CT etc.). Thus X-ray imaging can benefit from the work done on dynamic range enhancement methods developed initially for visible and infrared CMOS pixel sensors. A 2-D CMOS ASIC with 100um pixel pitch to demonstrate the feasibility of such methods in the context of X-ray imaging has been designed.

  16. The deep look onto the hard X-ray sky: The Swift - INTEGRAL X-ray (SIX) survey

    CERN Document Server

    Bottacini, Eugenio; Greiner, Jochen

    2012-01-01

    The super-massive black-holes in the centers of Active Galactic Nuclei (AGNs) are surrounded by obscuring matter that can block the nuclear radiation. Depending on the amount of blocked radiation, the flux from the AGN can be too faint to be detected by currently flying hard X-ray (above 15 keV) missions. At these energies only ~1% of the intensity of the Cosmic X-ray Background (CXB) can be resolved into point-like sources that are AGNs. In this work we address the question of the undetected sources contributing to the CXB with a very sensitive and new hard X-ray survey: the SIX survey that is obtained with the new approach of combining the Swift/BAT and INTEGRAL/IBIS X-ray observations. We merge the observations of both missions. This enhances the exposure time and reduces systematic uncertainties. As a result we obtain a new survey over a wide sky area of 6200 deg^2 that is more sensitive than the surveys of Swift/BAT or INTEGRAL/IBIS alone. Our sample comprises 113 sources: 86 AGNs (Seyfert-like and blaza...

  17. Compact hard x-ray imaging system with a large FOV

    Science.gov (United States)

    Katsuragawa, Miho; Takeda, Shin'ichiro; Sato, Goro; Harayama, Atsushi; Kennedy, Patrick K.; Deasy, Kieran; Watanabe, Shin; Takahashi, Tadayuki

    2016-07-01

    We have developed a compact hard X-ray imaging system composed of a cadmium telluride double-sided strip detector (CdTe-DSD) and a coded mask. We investigate the imaging performance using two different coded masks with different sizes and patterns. In our system, a CdTe-DSD of pitch 250μm is used in conjunction with a coded mask is placed 70-100 mm above the detector to form a compact imaging system. We obtained an angular resolution of up to 11.8 arc min, as measured from gamma-ray lines of point-like radioactive isotope sources. This is consistent with that expected from the geometry. The energy resolution is 1.7 keV (FWHM) at 60 keV and the energy range of imaging is from 5 keV to 122 keV. These results agree very well with Monte Carlo simulations of the detector.

  18. Weak hard X-ray emission from two broad absorption line quasars observed with NuSTAR: Compton-thick absorption or intrinsic X-ray weakness?

    DEFF Research Database (Denmark)

    Luo, B.; Brandt, W. N.; Alexander, D. M.

    2013-01-01

    We present Nuclear Spectroscopic Telescope Array (NuSTAR) hard X-ray observations of two X-ray weak broad absorption line (BAL) quasars, PG 1004+130 (radio loud) and PG 1700+518 (radio quiet). Many BAL quasars appear X-ray weak, probably due to absorption by the shielding gas between the nucleus ...

  19. On the origin of the hard X-ray tail in neutron-star X-ray binaries

    CERN Document Server

    Reig, P

    2016-01-01

    Neutron star X-ray binaries emit a compact, optically thick, relativistic radio jet during low-luminosity, usually hard states, as Galactic black-hole X-ray binaries do. When radio emission is bright, a hard power-law tail without evidence for an exponential cutoff is observed in most systems. We have developed a jet model that explains many spectral and timing properties of black-hole binaries in the states where a jet is present. Our goal is to investigate whether our jet model can reproduce the hard tail, with the correct range of photon index and the absence of a high-energy cutoff, in neutron-star X-ray binaries. We have performed Monte Carlo simulations of the Compton upscattering of soft, accretion-disk or boundary layer photons, in the jet and computed the emergent energy spectra, as well as the time lag of hard photons with respect to softer ones as a function of Fourier frequency. We demonstrate that our jet model explains the observed power-law distribution with photon index in the range 1.8-3. Wit...

  20. Promising X-ray fluorescence tests for superconducting tunneljunction detector

    Energy Technology Data Exchange (ETDEWEB)

    Friedrich, Stephan; Robinson, Arthur L.

    2001-05-15

    Scientists in the Physical Biosciences Division of the Ernest Orlando Berkeley National Laboratory (Berkeley Lab) studying transition metals in proteins with fluorescence-detected L-edge absorption spectroscopy have found the measurements to be extremely challenging. The difficulty is that the metal centers are present in very dilute concentrations so that their weak fluorescence is often obscured by strong background signals carbon and oxygen. To solve this problem, the Berkeley group has been working with researchers from the Advanced Detector Group at the Lawrence Livermore National Laboratory on an energy-dispersive superconducting tunnel junction x-ray detector. These devices in principle have the energy resolution needed to reveal the metal signal. The most recent results with the latest version of the detector on Beamline 4.0.1-2 at the Advanced Light Source (ALS) illustrate the promise of the cryogenic detector strategy not only for this application but also for spectroscopy of other types of dilute samples. Transition-metal complexes are key elements in many biologically important processes that are catalyzed by proteins (enzymes), photosynthesis being a prime example. The changes in that occur in electronic structure throughout a catalytic cycle are the subject of much research aimed at understanding the mechanisms of these processes. L-edge x-ray spectroscopy offers several advantages relative to the more common K-edge techniques, since it involves allowed transitions to the d-orbitals associated with metal-ligand bonding. It also has a rich multiplet structure interpretable by theory and higher spectral resolution.

  1. A diamond detector for inertial confinement fusion X-ray bang-time measurements at the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    MacPhee, A G; Brown, C; Burns, S; Celeste, J; Glenzer, S H; Hey, D; Jones, O S; Landen, O; Mackinnon, A J; Meezan, N; Parker, J; Edgell, D; Glebov, V Y; Kilkenny, J; Kimbrough, J

    2010-11-09

    An instrument has been developed to measure X-ray bang-time for inertial confinement fusion capsules; the time interval between the start of the laser pulse and peak X-ray emission from the fuel core. The instrument comprises chemical vapor deposited polycrystalline diamond photoconductive X-ray detectors with highly ordered pyrolytic graphite X-ray monochromator crystals at the input. Capsule bang-time can be measured in the presence of relatively high thermal and hard X-ray background components due to the selective band pass of the crystals combined with direct and indirect X-ray shielding of the detector elements. A five channel system is being commissioned at the National Ignition Facility at Lawrence Livermore National Laboratory for implosion optimization measurements as part of the National Ignition Campaign. Characteristics of the instrument have been measured demonstrating that X-ray bang-time can be measured with {+-} 30ps precision, characterizing the soft X-ray drive to +/- 1eV or 1.5%.

  2. Wide-field hard x-ray survey telescope: ProtoEXIST1

    Science.gov (United States)

    Hong, J.; Grindlay, J. E.; Chammas, N.; Allen, B.; Copete, A.; Said, B.; Burke, M.; Howell, J.; Gauron, T.; Baker, R. G.; Barthelmy, S. D.; Sheikh, S.; Gehrels, N.; Cook, W. R.; Burnham, J. A.; Harrison, F. A.; Collins, J.; Labov, S.; Garson, A., III; Krawczynski, H.

    2007-09-01

    We report our progress on the development of pixellated imaging CZT detector arrays for our first-generation balloon-borne wide-field hard X-ray (20 - 600 keV) telescope, ProtoEXIST1. Our ProtoEXIST program is a pathfinder for the High Energy Telescope (HET) on the Energetic X-ray Imaging Survey telescope (EXIST), a proposed implementation of the Black Hole Finder Probe. ProtoEXIST1 consists of four independent coded-aperture telescopes with close-tiled (~0.4 mm gaps) CZT detectors that preserve their 2.5mm pixel pitch. Multiple shielding/field-of-view configurations are planned to identify optimal geometry for the HET in EXIST. The primary technical challenge in ProtoEXIST is the development of large area, close-tiled modules of imaging CZT detectors (1000 cm2 for ProtoEXIST1), with all readout and control systems for the ASIC readout vertically stacked. We describe the overall telescope configuration of ProtoEXIST1 and review the current development status of the CZT detectors, from individual detector crystal units (DCUs) to a full detector module (DM). We have built the first units of each component for the detector plane and have completed a few Rev2 DCUs (2x2 cm2), which are under a series of tests. Bare DCUs (pre-crystal bonding) show high, uniform ASIC yield (~70%) and ~30% reduction in electronics noise compared to the Rev1 equivalent. A Rev1 DCU already achieved ~1.2% FWHM at 662 keV, and preliminary analysis of the initial radiation tests on a Rev2 DCU shows ~ 4 keV FWHM at 60 keV (vs. 4.7 keV for Rev1). We therefore expect about <=1% FWHM at 662 keV with the Rev2 detectors.

  3. Geometry calibration between X-ray source and detector for tomosynthesis with a portable X-ray system.

    Science.gov (United States)

    Sato, Kohei; Ohnishi, Takashi; Sekine, Masashi; Haneishi, Hideaki

    2017-05-01

    Tomosynthesis is attracting attention as a low-dose tomography technology compared with X-ray CT. However, conventional tomosynthesis imaging devices are large and stationary. Furthermore, there is a limitation in the working range of the X-ray source during image acquisition. We have previously proposed the use of a portable X-ray device for tomosynthesis that can be used for ward rounds and emergency medicine. The weight of this device can be reduced by using a flat panel detector (FPD), and flexibility is realized by the free placement of the X-ray source and FPD. Tomosynthesis using a portable X-ray device requires calibration of the geometry between the X-ray source and detector at each image acquisition. We propose a method for geometry calibration and demonstrate tomosynthesis image reconstruction by this method. An image processing-based calibration method using an asymmetric and multilayered calibration object (AMCO) is presented. Since the AMCO is always attached to the X-ray source housing for geometry calibration, the additional setting of a calibration object or marker around or on the patients is not required. The AMCO's multilayer structure improves the calibration accuracy, especially in the out-of-plane direction. Two experiments were conducted. The first was performed to evaluate the calibration accuracy using an XY positioning stage and a gonio stage. As a result, an accuracy of approximately 1 mm was achieved both in the in-plane and out-of-plane directions. An angular accuracy of approximately [Formula: see text] was confirmed. The second experiment was conducted to evaluate the reconstructed image using a foot model phantom. Only the sagittal plane could be clearly observed with the proposed method. We proposed a tomosynthesis imaging system using a portable X-ray device. From the experimental results, the proposed method could provide sufficient calibration accuracy and a clear sagittal plane of the reconstructed tomosynthesis image.

  4. Hard X-ray photoelectron spectroscopy: A few recent applications

    Energy Technology Data Exchange (ETDEWEB)

    Taguchi, M., E-mail: mtaguchi@spring8.or.jp [RIKEN SPring-8 Center, Sayo, Hyogo 679-5148 (Japan); Takata, Y.; Chainani, A. [RIKEN SPring-8 Center, Sayo, Hyogo 679-5148 (Japan)

    2013-10-15

    Highlights: ► We discuss recent applications of HAXPES carried out at BL29XU in SPring-8. ► We provide a brief description of the salient features of the instrument. ► The recoil effect of photoelectrons in core levels and valence band are discussed. ► We overview HAXPES studies of a series of 3d transition metal compounds. ► The extended cluster model for explaining well-screened feature is presented. -- Abstract: In this report, we discuss a few recent applications of hard X-ray photoelectron spectroscopy (HAXPES) carried out at the RIKEN beamline BL29XU in SPring-8. We first provide a brief description of the salient features of the instrument in operation at BL29 XU in SPring-8. HAXPES studies on the recoil effect of photoelectrons in core levels and valence band states are presented. The experiments show remarkable consistency with theoretical results and indicate the role of phonon excitations in the recoil effect of photoelectrons. We then overview HAXPES applied to the study of a series of 3d transition metal (TM) compounds. The HAXPES experimental results often show an additional well-screened feature in bulk sensitive electronic structure of strongly correlated compounds compared to surface sensitive spectra. The extended cluster model developed by us for explaining this well-screened feature is validated for a series of TM compounds. These results show that HAXPES is a valuable tool for the study of doping and temperature dependent electronic structure of solids with tremendous potential for future activities.

  5. Development of a Hard X-ray focal plane Compton Polarimeter: A compact polarimetric configuration with Scintillators and Si photomultipliers

    CERN Document Server

    Chattopadhyay, T; Goyal, S K; S., Mithun N P; Patel, A R; Shukla, R; Ladiya, T; Shanmugam, M; Patel, V R; Ubale, G P

    2015-01-01

    X-ray polarization measurement of cosmic sources provides two unique parameters namely degree and angle of polarization which can probe the emission mechanism and geometry at close vicinity of the compact objects. Specifically, the hard X-ray polarimetry is more rewarding because the sources are expected to be intrinsically highly polarized at higher energies. With the successful implementation of Hard X-ray optics in NuSTAR, it is now feasible to conceive Compton polarimeters as focal plane detectors. Such a configuration is likely to provide sensitive polarization measurements in hard X-rays with a broad energy band. We are developing a focal plane hard X-ray Compton polarimeter consisting of a plastic scintillator as active scatterer surrounded by a cylindrical array of CsI(Tl) scintillators. The scatterer is 5 mm diameter and 100 mm long plastic scintillator (BC404) viewed by normal PMT. The photons scattered by the plastic scatterer are collected by a cylindrical array of 16 CsI(Tl) scintillators (5 mm x...

  6. Hard X-ray Vela supernova observation on rocket experiment WRX-R

    Science.gov (United States)

    Stehlikova, V.; Urban, M.; Nentvich, O.; Daniel, V.; Sieger, L.; Tutt, J.

    2017-07-01

    This paper presents a hard X-ray telescope for the Vela nebula observation during a sounding rocket flight. The Water Recovery X-ray Rocket (WRX-R) experiment is organised by the Pennsylvania State University (PSU), USA with a primary payload of a soft X-ray spectroscope. The Czech team developed a hard X-ray Lobster-eye telescope as a secondary payload. The Czech experiment’s astrophysical object of study is the Vela pulsar in the centre of the Vela nebula.

  7. Hard X-ray quantum optics in thin films nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Haber, Johann Friedrich Albert

    2017-05-15

    This thesis describes quantum optical experiments with X-rays with the aim of reaching the strong-coupling regime of light and matter. We make use of the interaction which arises between resonant matter and X-rays in specially designed thin-film nanostructures which form X-ray cavities. Here, the resonant matter are Tantalum atoms and the Iron isotope {sup 57}Fe. Both limit the number of modes available to the resonant atoms for interaction, and enhances the interaction strength. Thus we have managed to observe a number of phenomena well-known in quantum optics, which are the building blocks for sophisticated applications in e.g. metrology. Among these are the strong coupling of light and matter and the concurrent exchange of virtual photons, often called Rabi oscillations. Furthermore we have designed and tested a type of cavity hitherto unused in X-ray optics. Finally, we develop a new method for synchrotron Moessbauer spectroscopy, which not only promises to yield high-resolution spectra, but also enables the retrieval of the phase of the scattered light. The results open new avenues for quantum optical experiments with X-rays, particularly with regards to the ongoing development of high-brilliance X-ray free-electron lasers.

  8. NuSTAR Hard X-ray Survey of the Galactic Center Region. I. Hard X-ray Morphology and Spectroscopy of the Diffuse Emission

    DEFF Research Database (Denmark)

    Mori, Kaya; Hailey, Charles J.; Krivonos, Roman

    2015-01-01

    pulsar wind nebulae (PWNe). NuSTAR detects non-thermal X-ray continuum emission spatially correlated with the 6.4 keV Fe K alpha fluorescence line emission associated with two Sgr A molecular clouds: MC1 and the Bridge. Broadband X-ray spectral analysis with a Monte-Carlo based X-ray reflection model......We present the first sub-arcminute images of the Galactic Center above 10 keV, obtained with NuSTAR. NuSTAR resolves the hard X-ray source IGR J17456-2901 into non-thermal X-ray filaments, molecular clouds, point sources, and a previously unknown central component of hard X-ray emission (CHXE). Nu......STAR detects four non-thermal X-ray filaments, extending the detection of their power-law spectra with Gamma similar to 1.3-2.3 up to similar to 50 keV. A morphological and spectral study of the filaments suggests that their origin may be heterogeneous, where previous studies suggested a common origin in young...

  9. The hard x-ray imager (HXI) onboard ASTRO-H

    Science.gov (United States)

    Nakazawa, Kazuhiro; Sato, Goro; Kokubun, Motohide; Enoto, Teruaki; Fukazawa, Yasushi; Hagino, Kouichi; Harayama, Atsushi; Hayashi, Katsuhiro; Kataoka, Jun; Katsuta, Junichiro; Laurent, Philippe; Lebrun, François; Limousin, Olivier; Makishima, Kazuo; Mizuno, Tsunefumi; Mori, Kunishiro; Nakamori, Takeshi; Nakano, Toshio; Noda, Hirofumi; Odaka, Hirokazu; Ohno, Masanori; Ohta, Masayuki; Saito, Shinya; Sato, Rie; Tajima, Hiroyasu; Takahashi, Hiromitsu; Takahashi, Tadayuki; Takeda, Shin'ichiro; Terada, Yukikatsu; Uchiyama, Hideki; Uchiyama, Yasunobu; Watanabe, Shin; Yamaoka, Kazutaka; Yatsu, Yoichi; Yuasa, Takayuki

    2016-07-01

    Hitomi X-ray observatory launched in 17 February 2016 had a hard X-ray imaging spectroscopy system made of two hard X-ray imagers (HXIs) coupled with two hard X-ray telescopes (HXTs). With 12 m focal length, they provide fine (2' half-power diameter; HPD) imaging spectroscopy at 5 to 80 keV. The HXI main imagers are made of 4 layers of Si and a CdTe semiconductor double-sided strip detectors, stacked to enhance detection efficiency as well as to enable photon interaction-depth sensing. Active shield made of 9 BGO scintillators surrounds the imager to provide with low background. Following the deployment of the Extensible Optical Bench (EOB) on 28 February, the HXI was gradually turned on. Two imagers successfully started observation on 14 March, and was operational till the incident lead to Hitomo loss, on 26 March. All detector channels, 1280 ch of imager and 11 channel of active shields and others each, worked well and showed performance consistent with those seen on ground. From the first light observation of G21.5-0.9 and the following Crab observations, 5-80 keV energy coverage and good detection efficiency were confirmed. With blank sky observations, we checked our background level. In some geomagnetic region, strong background continuum, presumably caused by trapped electron with energy 100 keV, is seen. But by cutting the high-background time-intervals, the background became significantly lower, typically with 1-3 x 10-4 counts s-1 keV-1 cm-2 (here cm2 is shown with detector geometrical area). Above 30 keV, line and continuum emission originating from activation of CdTe was significantly seen, though the level of 1-4 x 10-4 counts s-1 keV-1 cm-2 is still comparable to those seen in NuSTAR. By comparing the effective area and background rate, preliminary analysis shows that the HXI had a statistical sensitivity similar to NuSTAR for point sources, and more than twice better for largely extended sources.

  10. Evaluating scintillator performance in time-resolved hard X-ray studies at synchrotron light sources

    Energy Technology Data Exchange (ETDEWEB)

    Rutherford, Michael E.; Chapman, David J.; White, Thomas G. [Imperial College London, London (United Kingdom); Drakopoulos, Michael [Diamond Light Source, I12 Joint Engineering, Environmental, Processing (JEEP) Beamline, Didcot, Oxfordshire (United Kingdom); Rack, Alexander [European Synchrotron Radiation Facility, Grenoble (France); Eakins, Daniel E., E-mail: d.eakins@imperial.ac.uk [Imperial College London, London (United Kingdom)

    2016-03-24

    Scintillator performance in time-resolved, hard, indirect detection X-ray studies on the sub-microsecond timescale at synchrotron light sources is reviewed, modelled and examined experimentally. LYSO:Ce is found to be the only commercially available crystal suitable for these experiments. The short pulse duration, small effective source size and high flux of synchrotron radiation is ideally suited for probing a wide range of transient deformation processes in materials under extreme conditions. In this paper, the challenges of high-resolution time-resolved indirect X-ray detection are reviewed in the context of dynamic synchrotron experiments. In particular, the discussion is targeted at two-dimensional integrating detector methods, such as those focused on dynamic radiography and diffraction experiments. The response of a scintillator to periodic synchrotron X-ray excitation is modelled and validated against experimental data collected at the Diamond Light Source (DLS) and European Synchrotron Radiation Facility (ESRF). An upper bound on the dynamic range accessible in a time-resolved experiment for a given bunch separation is calculated for a range of scintillators. New bunch structures are suggested for DLS and ESRF using the highest-performing commercially available crystal LYSO:Ce, allowing time-resolved experiments with an interframe time of 189 ns and a maximum dynamic range of 98 (6.6 bits)

  11. Solar flare hard and soft x ray relationship determined from SMM HXRBS and BCS data

    Science.gov (United States)

    Toot, G. David

    1989-01-01

    The exact nature of the solar flare process is still somewhat a mystery. A key element to understanding flares if the relationship between the hard x rays emitted by the most energetic portions of the flare and the soft x rays from other areas and times. This relationship was studied by comparing hard x ray light curved from the Hard X-Ray Burst Spectrometer (HXRBS) with the soft x ray light curve and its derivation from the Bent Crystal Spectrometer (BCS) which is part of the X-Ray Polychrometer (XRP), these instruments being on the Solar Maximum Mission spacecraft (SMM). Data sample was taken from flares observed with the above instruments during 1980, the peak of the previous maximum of solar activity. Flares were chosen based on complete coverage of the event by several instruments. The HXRBS data covers the x ray spectrum from about 25 keV to about 440 keV in 15 spectral channels, while the BCS data used covers a region of the Spectrum around 3 angstroms including emission from the Ca XIX ion. Both sets of data were summed over their spectral ranges and plotted against time at a maximum time resolution of around 3 seconds. The most popular theory of flares holds that a beam of electrons produces the hard x rays by bremsstrahlung while the soft x rays are the thermal response to this energy deposition. The question is whether the rate of change of soft x ray emission might reflect the variability of the electron beam and hence the variability of the hard x rays. To address this, we took the time derivative of the soft x ray light curve and compared it to the hard flares, 12 of them showed very closed agreement between the soft x ray derivative and the hard x ray light curve. The other five did not show this behavior but were similar to each other in general soft x ray behavior. Efforts to determine basic differences between the two kinds of flares continue. In addition the behavior of soft x ray temperature of flares was examined.

  12. Cumulative luminosity distributions of Supergiant Fast X-ray Transients in hard X-rays

    CERN Document Server

    Paizis, A

    2014-01-01

    We have analyzed in a systematic way about nine years of INTEGRAL data (17-100 keV) focusing on Supergiant Fast X-ray Transients (SFXTs) and three classical High Mass X-ray Binaries (HMXBs). Our approach has been twofold: image based analysis, sampled over a ~ks time frame to investigate the long-term properties of the sources, and lightcurve based analysis, sampled over a 100s time frame to seize the fast variability of each source during its ~ks activity. We find that while the prototypical SFXTs (IGR J17544-2619, XTE J1739-302 and SAX J1818.6-1703) are among the sources with the lowest ~ks based duty cycle ($<$1% activity over nine years of data), when studied at the 100s level, they are the ones with the highest detection percentage, meaning that, when active, they tend to have many bright short-term flares with respect to the other SFXTs. To investigate in a coherent and self consistent way all the available results within a physical scenario, we have extracted cumulative luminosity distributions for ...

  13. The high resolution X-ray imaging detector planes for the MIRAX mission

    Science.gov (United States)

    Rodrigues, B. H. G.; Grindlay, J. E.; Allen, B.; Hong, J.; Barthelmy, S.; Braga, J.; D'Amico, F.; Rothschild, R. E.

    2013-09-01

    The MIRAX X-ray observatory, the first Brazilian-led astrophysics space mission, is designed to perform an unprecedented wide-field, wide-band hard X-ray (5-200 keV) survey of Galactic X-ray transient sources. In the current configuration, MIRAX will carry a set of four coded-masks telescopes with high spatial resolution Cadmium Zinc Telluride (CZT) detector planes, each one consisting of an array of 64 closely tiled CZT pixelated detectors. Taken together, the four telescopes will have a total detection area of 959 cm2, a large field of view (60° × 60° FWHM), high angular resolution for this energy range (6 arcmin) and very good spectral resolution ( ~ 2 keV @ 60 keV). A stratospheric balloon-borne prototype of one of the MIRAX telescopes has been developed, tested and flown by the Harvard-Smithsonian Center for Astrophysics (CfA) as part of the ProtoEXIST program. In this paper we show results of validation and calibration tests with individual CZT detectors of the ProtoEXIST second generation experiment (P2). Each one of 64 detector units of the P2 detector plane consists of an ASIC, developed by Caltech for the NuSTAR telescope, hybridized to a CZT crystal with 0.6 mm pixel size. The performance of each detector was evaluated using radioactive sources in the laboratory. The calibration results show that the P2 detectors have average energy resolution of ~ 2.1 keV @ 60 keV and 2.3 @ 122 keV. P2 was also successfully tested on near-space environment on a balloon flight, demonstrating the detector unit readiness for integration on a space mission telescope, as well as satisfying all MIRAX mission requirements.

  14. Investigation of chemical vapour deposition diamond detectors by X- ray micro-beam induced current and X-ray micro-beam induced luminescence techniques

    CERN Document Server

    Olivero, P; Vittone, E; Fizzotti, F; Paolini, C; Lo Giudice, A; Barrett, R; Tucoulou, R

    2004-01-01

    Tracking detectors have become an important ingredient in high-energy physics experiments. In order to survive the harsh detection environment of the Large Hadron Collider (LHC), trackers need to have special properties. They must be radiation hard, provide fast collection of charge, be as thin as possible and remove heat from readout electronics. The unique properties of diamond allow it to fulfill these requirements. In this work we present an investigation of the charge transport and luminescence properties of "detector grade" artificial chemical vapour deposition (CVD) diamond devices developed within the CERN RD42 collaboration, performed by means of X-ray micro-beam induced current collection (XBICC) and X-ray micro- beam induced luminescence (XBIL) techniques. XBICC technique allows quantitative estimates of the transport parameters of the material to be evaluated and mapped with micrometric spatial resolution. In particular, the high resolution and sensitivity of the technique has allowed a quantitati...

  15. Kilohertz sources of hard x rays and fast ions with femtosecond laser plasmas

    Science.gov (United States)

    Thoss, A.; Richardson, M.; Korn, G.; Faubel, M.; Stiel, H.; Vogt, U.; Elsaesser, T.

    2003-01-01

    We demonstrate a new, stable, kilohertz femtosecond laser plasma source of hard-x-ray continuum and Kα emission that uses a microscopic liquid jet target that is continuous and debris free. Plasmas produced by ultrashort (50-fs) intense laser pulses from a fine (10-30-μm diameter) liquid Ga jet emit bright 9.3- and 10.3-keV Kα and Kβ lines superimposed on a multikilovolt bremmstrahlung continuum. Kilohertz femtosecond x-ray sources will find many applications in time-resolved x-ray diffraction and microscopy studies. As high-intensity lasers become more compact and operate at increasingly high repetition-rates, they require a target configuration that is both repeatable from shot to shot and debris free. Our target provides a pristine, unperturbed filament surface at rates >100 kHz. A number of liquid metal targets are considered. We show the hard-x-ray spectrum described above. The source was generated by a 50-fs-duration, 1-kHz, 2-W, high-intensity Ti:sapphire laser. Using the same technology, we also generate forward-going sub-mega-electron-volt (sub-MeV) protons from a 10-μm liquid water target at 1-kHz repetition rates. Kilohertz sources of high-energy ions will find many applications in time-resolved particle interaction studies and will lead to efficient generation of short-lived isotopes for use in nuclear medicine and other applications. The protons were detected with CR-39 track detectors in both the forward and the backward directions up to energies of ~500 keV. As the intensity of compact high-repetition-rate lasers sources increases, we can expect improvements in the energy, conversion efficiency, and directionality to occur. The effect of these developments is discussed. As compact, high-repetition-rate femtosecond laser technology reaches focused intensities of ~1019 W/cm2, many new applications of high-repetition-rate hard-x-ray and MeV ion sources will become practical.

  16. Fluence thresholds for grazing incidence hard x-ray mirrors

    Science.gov (United States)

    Aquila, A.; Sobierajski, R.; Ozkan, C.; Hájková, V.; Burian, T.; Chalupský, J.; Juha, L.; Störmer, M.; Bajt, S.; Klepka, M. T.; DłuŻewski, P.; Morawiec, K.; Ohashi, H.; Koyama, T.; Tono, K.; Inubushi, Y.; Yabashi, M.; Sinn, H.; Tschentscher, T.; Mancuso, A. P.; Gaudin, J.

    2015-06-01

    X-ray Free Electron Lasers (XFELs) have the potential to contribute to many fields of science and to enable many new avenues of research, in large part due to their orders of magnitude higher peak brilliance than existing and future synchrotrons. To best exploit this peak brilliance, these XFEL beams need to be focused to appropriate spot sizes. However, the survivability of X-ray optical components in these intense, femtosecond radiation conditions is not guaranteed. As mirror optics are routinely used at XFEL facilities, a physical understanding of the interaction between intense X-ray pulses and grazing incidence X-ray optics is desirable. We conducted single shot damage threshold fluence measurements on grazing incidence X-ray optics, with coatings of ruthenium and boron carbide, at the SPring-8 Angstrom compact free electron laser facility using 7 and 12 keV photon energies. The damage threshold dose limits were found to be orders of magnitude higher than would naively be expected. The incorporation of energy transport and dissipation via keV level energetic photoelectrons accounts for the observed damage threshold.

  17. Fluence thresholds for grazing incidence hard x-ray mirrors

    Energy Technology Data Exchange (ETDEWEB)

    Aquila, A.; Ozkan, C.; Sinn, H.; Tschentscher, T.; Mancuso, A. P.; Gaudin, J. [European XFEL GmbH, Albert-Einstein-Ring 19, Hamburg D-22671 (Germany); Sobierajski, R.; Klepka, M. T.; Dłużewski, P.; Morawiec, K. [Institute of Physics, PAS Al. Lotnikw 32/46, Warsaw PL-02-668 (Poland); Hájková, V.; Burian, T.; Chalupský, J.; Juha, L. [Institute of Physics, ASCR, Na Slovance 2, CZ 182 21 Prague 8 (Czech Republic); Störmer, M. [Helmholtz-Zentrum Geesthacht, Max-Planck-Straße 1, Geesthacht D-21502 (Germany); Bajt, S. [Deutsches Elektronen-Synchrotron, Notkestraße 85, Hamburg D-22607 (Germany); Ohashi, H.; Koyama, T.; Tono, K. [RIKEN/SPring-8 Kouto 1-1-1, Sayo, Hyogo 679-5148 (Japan); Japan Synchrotron Radiation Research Institute (JASRI), Kouto 1-1-1, Sayo, Hyogo 679-5198 (Japan); Inubushi, Y. [RIKEN/SPring-8 Kouto 1-1-1, Sayo, Hyogo 679-5148 (Japan); and others

    2015-06-15

    X-ray Free Electron Lasers (XFELs) have the potential to contribute to many fields of science and to enable many new avenues of research, in large part due to their orders of magnitude higher peak brilliance than existing and future synchrotrons. To best exploit this peak brilliance, these XFEL beams need to be focused to appropriate spot sizes. However, the survivability of X-ray optical components in these intense, femtosecond radiation conditions is not guaranteed. As mirror optics are routinely used at XFEL facilities, a physical understanding of the interaction between intense X-ray pulses and grazing incidence X-ray optics is desirable. We conducted single shot damage threshold fluence measurements on grazing incidence X-ray optics, with coatings of ruthenium and boron carbide, at the SPring-8 Angstrom compact free electron laser facility using 7 and 12 keV photon energies. The damage threshold dose limits were found to be orders of magnitude higher than would naively be expected. The incorporation of energy transport and dissipation via keV level energetic photoelectrons accounts for the observed damage threshold.

  18. X-ray detectors at the Linac Coherent Light Source.

    Science.gov (United States)

    Blaj, Gabriel; Caragiulo, Pietro; Carini, Gabriella; Carron, Sebastian; Dragone, Angelo; Freytag, Dietrich; Haller, Gunther; Hart, Philip; Hasi, Jasmine; Herbst, Ryan; Herrmann, Sven; Kenney, Chris; Markovic, Bojan; Nishimura, Kurtis; Osier, Shawn; Pines, Jack; Reese, Benjamin; Segal, Julie; Tomada, Astrid; Weaver, Matt

    2015-05-01

    Free-electron lasers (FELs) present new challenges for camera development compared with conventional light sources. At SLAC a variety of technologies are being used to match the demands of the Linac Coherent Light Source (LCLS) and to support a wide range of scientific applications. In this paper an overview of X-ray detector design requirements at FELs is presented and the various cameras in use at SLAC are described for the benefit of users planning experiments or analysts looking at data. Features and operation of the CSPAD camera, which is currently deployed at LCLS, are discussed, and the ePix family, a new generation of cameras under development at SLAC, is introduced.

  19. The High Resolution X-Ray Imaging Detector Planes for the MIRAX Mission

    CERN Document Server

    Rodrigues, Barbara H G; Allen, Branden; Hong, Jaesub; Barthelmy, Scott; Braga, Joao; D'Amico, Flavio; Rothschild, Richard E

    2013-01-01

    The MIRAX X-ray observatory, the first Brazilian-led astrophysics space mission, is designed to perform an unprecedented wide-field, wide-band hard X-ray (5-200 keV) survey of Galactic X-ray transient sources. In the current configuration, MIRAX will carry a set of four coded-mask telescopes with high spatial resolution Cadmium Zinc Telluride (CZT) detector planes, each one consisting of an array of 64 closely tiled CZT pixelated detectors. Taken together, the four telescopes will have a total detection area of 959 cm^2, a large field of view (60x60 degrees FWHM), high angular resolution for this energy range (6 arcmin) and very good spectral resolution (~2 keV @ 60 keV). A stratospheric balloon-borne prototype of one of the MIRAX telescopes has been developed, tested and flown by the Harvard-Smithsonian Center for Astrophysics (CfA) as part of the ProtoEXIST program. In this paper we show results of validation and calibration tests with individual CZT detectors of the ProtoEXIST second generation experiment ...

  20. Stereoscopic observations of a solar flare hard X-ray source in the high corona

    Science.gov (United States)

    Kane, S. R.; Mctiernan, J.; Loran, J.; Fenimore, E. E.; Klebesadel, R. W.; Laros, J. G.

    1992-01-01

    The vertical structure of the impulsive and gradual hard X-ray sources in high coronae and the characteristics of the impulsive soft X-ray emission are investigated on the basis of PVE, ICE, and GOES observations of the energetic flare on February 16, 1984. The average photon spectra observed by these instruments during the impulsive and gradual hard X-ray bursts are summarized. A comparison of these unocculted and partially occulted spectra shows that the sources of the impulsive hard X-ray (greater than about 25 keV) and impulsive soft X-ray (2-5 keV) emissions in this flare extended to coronal altitudes greater than about 200,000 km above the photosphere. At about 100 keV, the ratio of the coronal source brightness to the total source brightness was 0.001 during the impulsive phase and less than about 0.01 during the gradual hard X-ray burst. The sources of the gradual hard X-ray burst and gradual soft X-ray burst were almost completely occulted, indicating that these sources were located at heights less than 200,000 km above the photosphere.

  1. NuSTAR HARD X-RAY SURVEY OF THE GALACTIC CENTER REGION. I. HARD X-RAY MORPHOLOGY AND SPECTROSCOPY OF THE DIFFUSE EMISSION

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Kaya; Hailey, Charles J.; Perez, Kerstin; Nynka, Melania; Zhang, Shuo; Canipe, Alicia M. [Columbia Astrophysics Laboratory, Columbia University, New York, NY 10027 (United States); Krivonos, Roman; Tomsick, John A.; Barrière, Nicolas; Boggs, Steven E.; Craig, William W. [Space Sciences Laboratory, University of California, Berkeley, CA 94720 (United States); Hong, Jaesub [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138 (United States); Ponti, Gabriele [Max-Planck-Institut f. extraterrestrische Physik, HEG, Garching (Germany); Bauer, Franz [Instituto de Astrofísica, Facultad de Física, Pontificia Universidad Católica de Chile, 306, Santiago 22 (Chile); Alexander, David M. [Department of Physics, Durham University, Durham DH1 3LE (United Kingdom); Baganoff, Frederick K. [Kavli Institute for Astrophysics and Space Research, Massachusets Institute of Technology, Cambridge, MA 02139 (United States); Barret, Didier [Université de Toulouse, UPS-OMP, IRAP, Toulouse (France); Christensen, Finn E. [DTU Space—National Space Institute, Technical University of Denmark, Elektrovej 327, DK-2800 Lyngby (Denmark); Forster, Karl [Cahill Center for Astronomy and Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Giommi, Paolo, E-mail: kaya@astro.columbia.edu [ASI Science Data Center, Via del Politecnico snc I-00133, Roma (Italy); and others

    2015-12-01

    We present the first sub-arcminute images of the Galactic Center above 10 keV, obtained with NuSTAR. NuSTAR resolves the hard X-ray source IGR J17456–2901 into non-thermal X-ray filaments, molecular clouds, point sources, and a previously unknown central component of hard X-ray emission (CHXE). NuSTAR detects four non-thermal X-ray filaments, extending the detection of their power-law spectra with Γ ∼ 1.3–2.3 up to ∼50 keV. A morphological and spectral study of the filaments suggests that their origin may be heterogeneous, where previous studies suggested a common origin in young pulsar wind nebulae (PWNe). NuSTAR detects non-thermal X-ray continuum emission spatially correlated with the 6.4 keV Fe Kα fluorescence line emission associated with two Sgr A molecular clouds: MC1 and the Bridge. Broadband X-ray spectral analysis with a Monte-Carlo based X-ray reflection model self-consistently determined their intrinsic column density (∼10{sup 23} cm{sup −2}), primary X-ray spectra (power-laws with Γ ∼ 2) and set a lower limit of the X-ray luminosity of Sgr A* flare illuminating the Sgr A clouds to L{sub X} ≳ 10{sup 38} erg s{sup −1}. Above ∼20 keV, hard X-ray emission in the central 10 pc region around Sgr A* consists of the candidate PWN G359.95–0.04 and the CHXE, possibly resulting from an unresolved population of massive CVs with white dwarf masses M{sub WD} ∼ 0.9 M{sub ⊙}. Spectral energy distribution analysis suggests that G359.95–0.04 is likely the hard X-ray counterpart of the ultra-high gamma-ray source HESS J1745–290, strongly favoring a leptonic origin of the GC TeV emission.

  2. The Al sub x Ga sub 1 sub - sub x As X-ray imaging detector

    CERN Document Server

    Pozela, K; Dileenas, A; Jasutis, V; Dapkus, L; Jucienee, V

    2001-01-01

    An X-ray imaging detector based on the graded-gap Al sub x Ga sub 1 sub - sub x As structures with the CCD camera as an image read-out tool is investigated. High X-ray - light conversion efficiency and X-ray image spatial resolution better than 20 line/mm are obtained.

  3. Angular resolution measurements at SPring-8 of a hard x-ray optic for the New Hard X-ray Mission

    Science.gov (United States)

    Spiga, D.; Raimondi, L.; Furuzawa, A.; Basso, S.; Binda, R.; Borghi, G.; Cotroneo, V.; Grisoni, G.; Kunieda, H.; Marioni, F.; Matsumoto, H.; Mori, H.; Miyazawa, T.; Negri, B.; Orlandi, A.; Pareschi, G.; Salmaso, B.; Tagliaferri, G.; Uesugi, K.; Valsecchi, G.; Vernani, D.

    2011-09-01

    The realization of X-ray telescopes with imaging capabilities in the hard (> 10 keV) X-ray band requires the adoption of optics with shallow (=10 m shall be produced and tested. Full-illumination tests of such mirrors are usually performed with onground X-ray facilities, aimed at measuring their effective area and the angular resolution; however, they in general suffer from effects of the finite distance of the X-ray source, e.g. a loss of effective area for double reflection. These effects increase with the focal length of the mirror under test; hence a "partial" full-illumination measurement might not be fully representative of the in-flight performances. Indeed, a pencil beam test can be adopted to overcome this shortcoming, because a sector at a time is exposed to the X-ray flux, and the compensation of the beam divergence is achieved by tilting the optic. In this work we present the result of a hard X-ray test campaign performed at the BL20B2 beamline of the SPring-8 synchrotron radiation facility, aimed at characterizing the Point Spread Function (PSF) of a multilayer-coated Wolter-I mirror shell manufactured by Nickel electroforming. The mirror shell is a demonstrator for the NHXM hard X-ray imaging telescope (0.3 - 80 keV), with a predicted HEW (Half Energy Width) close to 20 arcsec. We show some reconstructed PSFs at monochromatic X-ray energies of 15 to 63 keV, and compare them with the PSFs computed from post-campaign metrology data, self-consistently treating profile and roughness data by means of a method based on the Fresnel diffraction theory. The modeling matches the measured PSFs accurately.

  4. Design and experimental study of a two-dimensional position sensitive X-ray detector

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    A prototype of a two-dimensional position sensitive X-ray detector was designed and constructed for small angle X-ray scattering experiments at BSFR (Beijing Synchrotron Radiation Facility). The detector is based on MWPC with cathode strip readout, and has a sensitive area of 200 mmx200 mm. The spatial resolution (FWHM) of about 210 μm along the anode wire direction was obtained from the 55Fe X-ray test of the detector.

  5. A large area telescope for balloon-borne hard X-ray astronomy

    Science.gov (United States)

    Baker, R. E.; Barbaglia, G.; Bazzano, A.; Boccaccini, L.; Bussini, A.; Carzaniga, A.; Court, A.; Dean, A. J.; Dipper, N. A.; Ferrandi, G.; Haskell, N.; La Padula, C.; Lewis, R. A.; Maccagni, D.; Mastropietro, M.; Patriarca, R.; Perotti, F.; Polcaro, V. F.; Quadrini, E.; Ramsden, D.; Sembay, S.; Spicer, R.; Ubertini, P.; Villa, G.; Whatley, D.

    1984-12-01

    A balloon-borne hard X-ray telescope is described that has been designed to make highly sensitive observations of cosmic sources in the energy range 15 to 300 keV. The payload is characterized by a combination of NaI(Tl) based detector of a novel design and spectroscopic proportional counters, providing a total sensitive area of 5000 cm2 and a 1 standard deviation sensitivity at the level of about 4 × 10-6 photons cm-2 s-1 keV-1. All of the telescope sub-systems are described including the micro-processor based orientation platform that provides a pointing stability of better than 10 arc min. The physical characteristics of the detectors are included along with a summary of the telescope performance during a balloon flight in 1982.

  6. Hard X-ray irradiation of cosmic silicate analogs: structural evolution and astrophysical implications

    CERN Document Server

    Gavilan, L; Simionovici, A; Lemaire, J L; Sabri, T; Foy, E; Yagoubi, S; Henning, T; Salomon, D; Martinez-Criado, G

    2016-01-01

    Protoplanetary disks, interstellar clouds, and active galactic nuclei, contain X-ray dominated regions. X-rays interact with the dust and gas present in such environments. While a few laboratory X-ray irradiation experiments have been performed on ices, X-ray irradiation experiments on bare cosmic dust analogs have been scarce up to now. Our goal is to study the effects of hard X-rays on cosmic dust analogs via in-situ X-ray diffraction. By using a hard X-ray synchrotron nanobeam, we seek to simulate cumulative X-ray exposure on dust grains during their lifetime in these astrophysical environments, and provide an upper limit on the effect of hard X-rays on dust grain structure. We prepared enstatite nanograins, analogs to cosmic silicates, via the melting-quenching technique. These amorphous grains were then annealed to obtain polycrystalline grains. These were characterized via scanning electron microscopy and high-resolution transmission electron microscopy before irradiation. Powder samples were prepared i...

  7. A vacuum photoemission detector for X-ray tomography on the ITER facility

    NARCIS (Netherlands)

    Barykov, IA; Gott, YV; Stepanenko, MM

    2004-01-01

    A vacuum photoemission detector designed for plasma tornography in X rays on the ITER facility is described. Such detectors allow X rays to be detected in the presence of intense neutron and gamma-photon fluxes. The results of tests of a prototype of this detector on a Co-60 source of gamma rays, it

  8. X-ray detector for automatic exposure control using ionization chamber filled with xenon gas

    CERN Document Server

    Nakagawa, A; Yoshida, T

    2003-01-01

    This report refers to our newly developed X-ray detector for reliable automatic X-ray exposure control, which is to be widely used for X-ray diagnoses in various clinical fields. This new detector utilizes an ionization chamber filled with xenon gas, in contrast to conventional X-ray detectors which use ionization chambers filled with air. Use of xenon gas ensures higher sensitivity and thinner design of the detector. The xenon gas is completely sealed in the chamber, so that the influence of the changes in ambient environments is minimized. (author)

  9. Suzaku Detection of Diffuse Hard X-Ray Emission outside Vela X

    CERN Document Server

    Katsuda, Satoru; Petre, Robert; Yamaguchi, Hiroya; Tsunemi, Hiroshi; Bocchino, Fabrizio; Bamba, Aya; Miceli, Marco; Hewitt, John W; Temim, Tea; Uchida, Hiroyuki; Yoshii, Rie

    2011-01-01

    Vela X is a large, 3x2 degrees, radio-emitting pulsar wind nebula (PWN) powered by the Vela pulsar in the Vela supernova remnant. Using four Suzaku/XIS observations pointed just outside Vela X, we find hard X-ray emission extending throughout the fields of view. The hard X-ray spectra are well represented by a power-law. The photon index is measured to be constant at Gamma~2.4, similar to that of the southern outer part of Vela X. The power-law flux decreases with increasing distance from the pulsar. These properties lead us to propose that the hard X-ray emission is associated with the Vela PWN. The larger X-ray extension found in this work strongly suggests that distinct populations relativistic electrons form the X-ray PWN and Vela X, as was recently inferred from multiwavelength spectral modeling of Vela X.

  10. Suzaku Detection of Diffuse Hard X-Ray Emission Outside Vela X

    Science.gov (United States)

    Katsuda, Satoru; Mori, Koji; Petre, Robert; Yamaguchi, Hiroya; Tsunemi, Hiroshi; Bocchino, Fabrizio; Bamba, Aya; Miceli, Marco; Hewitt, John W.; Temim, Tea; Uchida, Hiroyuki; Yoshii, Rie

    2011-01-01

    Vela X is a large, 3 deg x 2 deg, radio-emitting pulsar wind nebula (PWN) powered by the Vela pulsar in the Vela supernova remnant. Using four Suzaku/XIS observations pointed just outside Vela X, we find hard X-ray emission extending throughout the fields of view. The hard X-ray spectra are well represented by a power-law. The photon index is measured to be constant at Gamma approximates 2.4, similar to that of the southern outer part of Vela X. The power-law flux decreases with increasing distance from the pulsar. These properties lead us to propose that the hard X-ray emission is associated with the Vela PWN. The larger X-ray extension found in this work strongly suggests that distinct populations relativistic electrons form the X-ray PWN and Vela X, as was recently inferred from multiwavelength spectral modeling of Vela X.

  11. Angular resolution measurements at SPring-8 of a hard X-ray optic for the New Hard X-ray Mission

    CERN Document Server

    Spiga, D; Furuzawa, A; Basso, S; Binda, R; Borghi, G; Cotroneo, V; Grisoni, G; Kunieda, H; Marioni, F; Matsumoto, H; Mori, H; Miyazawa, T; Negri, B; Orlandi, A; Pareschi, G; Salmaso, B; Tagliaferri, G; Uesugi, K; Valsecchi, G; Vernani, D

    2015-01-01

    The realization of X-ray telescopes with imaging capabilities in the hard (> 10 keV) X-ray band requires the adoption of optics with shallow (10 m shall be produced and tested. Full-illumination tests of such mirrors are usually performed with on- ground X-ray facilities, aimed at measuring their effective area and the angular resolution; however, they in general suffer from effects of the finite distance of the X-ray source, e.g. a loss of effective area for double reflection. These effects increase with the focal length of the mirror under test; hence a "partial" full-illumination measurement might not be fully representative of the in-flight performances. Indeed, a pencil beam test can be adopted to overcome this shortcoming, because a sector at a time is exposed to the X-ray flux, and the compensation of the beam divergence is achieved by tilting the optic. In this work we present the result of a hard X-ray test campaign performed at the BL20B2 beamline of the SPring-8 synchrotron radiation facility, aime...

  12. Hard X-ray and Infrared Emission from Apparently Single White Dwarfs

    CERN Document Server

    Chu, Y H; Guerrero, M A; Su, K Y L

    2007-01-01

    The photospheric emission of a white dwarf (WD) is not expected to be detectable in hard X-rays or the mid-IR. Hard X-ray (~1 keV) emission associated with a WD is usually attributed to a binary companion; however, emission at 1 keV has been detected from three WDs without companions: KPD 0005+5106, PG 1159, and WD 2226-210. The origin of their hard X-ray emission is unknown, although it has been suggested that WD 2226-210 has a late-type companion whose coronal activity is responsible for the hard X-rays. Recent Spitzer observations of WD 2226-210 revealed mid-IR excess emission indicative of the existence of a dust disk. It now becomes much less clear whether WD 2226-210's hard X-ray emission originates from the corona of a late-type companion or from the accretion of the disk material. High-quality X-ray observations and mid-IR observations of KPD 0005+5106 and PG 1159 are needed to help us understand the origin of their hard X-ray emission.

  13. Anti-correlated hard X-ray time lags in Galactic black hole sources

    CERN Document Server

    Sriram, K; Pendharkar, J K; Rao, A R; Pendharkar, Jayant K.

    2007-01-01

    We investigate the accretion disk geometry in Galactic black hole sources by measuring the time delay between soft and hard X-ray emissions. Similar to the recent discoveries of anti-correlated hard X-ray time lags in Cyg X-3 and GRS 1915+105, we find that the hard X-rays are anti-correlated with soft X-rays with a significant lag in another source: XTE J1550-564. We also find the existence of pivoting in the model independent X-ray spectrum during these observations. We investigate time-resolved X-ray spectral parameters and find that the variation in these parameters is consistent with the idea of a truncated accretion disk. The QPO frequency, which is a measure of the size of truncated accretion disk, too changes indicating that the geometric size of the hard X-ray emitting region changes along with the spectral pivoting and soft X-ray flux. Similar kind of delay is also noticed in 4U 1630-47.

  14. Hard X-ray Spectroscopy of Obscured AGN with NuSTAR

    Science.gov (United States)

    Balokovic, Mislav; Harrison, Fiona; NuSTAR Extragalactic Surveys Team

    2017-01-01

    The Nuclear Spectroscopic Telescope Array (NuSTAR) has enabled studies of the local active galactic nuclei (AGN) to extend into the hard X-ray band, up to 79 keV, with unprecedented spatial resolution and sensitivity. As a part of its extragalactic program, NuSTAR is surveying the nearby population of AGN detected at hard X-ray energies by the Swift Burst Alert Telescope (Swift/BAT), selecting even the most obscured local AGN. I will highlight some of the results based on broadband X-ray spectroscopy of individual targets and present my work on the large representative sample of more than a hundred nearby obscured AGN, which constitutes the largest available atlas of hard X-ray spectra of obscured AGN to date. The high quality of the data allows us to probe the details of AGN structures such as the X-ray-emitting corona and the toroidal obscurer in the under-explored spectral window above 10 keV. I will present both phenomenological results important for synthesis models of the cosmic X-ray background, and a novel approach for constraining the geometry of the gas surrounding the supermassive black hole (including the accretion disk, the broad-line region, and the torus) from the hard X-ray band. Finally, I will discuss how what we learned from this survey of local AGN relates to deeper high-redshift X-ray surveys and AGN structure probes at other wavelengths.

  15. A Hard X-Ray Power-Law Spectral Cutoff in Centaurus X-4

    DEFF Research Database (Denmark)

    Chakrabarty, Deepto; Tomsick, John A.; Grefenstette, Brian W.

    2015-01-01

    The low-mass X-ray binary Cen X-4 is the brightest and closest (<1.2 kpc) quiescent neutron star transient. Previous 0.5-10 keV X-ray observations of Cen X-4 in quiescence identified two spectral components: soft thermal emission from the neutron star atmosphere and a hard power-law tail of unkno...

  16. Deterministic retrieval of complex Green's functions using hard X rays.

    Science.gov (United States)

    Vine, D J; Paganin, D M; Pavlov, K M; Uesugi, K; Takeuchi, A; Suzuki, Y; Yagi, N; Kämpfe, T; Kley, E-B; Förster, E

    2009-01-30

    A massively parallel deterministic method is described for reconstructing shift-invariant complex Green's functions. As a first experimental implementation, we use a single phase contrast x-ray image to reconstruct the complex Green's function associated with Bragg reflection from a thick perfect crystal. The reconstruction is in excellent agreement with a classic prediction of dynamical diffraction theory.

  17. Grating-based at-wavelength metrology of hard x-ray reflective optics.

    Science.gov (United States)

    Berujon, Sebastien; Ziegler, Eric

    2012-11-01

    A mean of characterizing the tangential shape of a hard x-ray mirror is presented. Derived from a group of methods operating under visible light, its application in the x-ray domain using an x-ray absorption grating allows recovery of the mirror shape with nanometer accuracy and submillimeter spatial resolution. The method works with incoherent light, does not require any a priori information about the mirror characteristics and allows shape reconstruction of x-ray reflective optics under thermal and mechanical working conditions.

  18. Hard X-ray irradiation of cosmic silicate analogs: structural evolution and astrophysical implications

    Science.gov (United States)

    Gavilan, L.; Jäger, C.; Simionovici, A.; Lemaire, J. L.; Sabri, T.; Foy, E.; Yagoubi, S.; Henning, T.; Salomon, D.; Martinez-Criado, G.

    2016-03-01

    Context. Protoplanetary disks, interstellar clouds, and active galactic nuclei contain X-ray-dominated regions. X-rays interact with the dust and gas present in such environments. While a few laboratory X-ray irradiation experiments have been performed on ices, X-ray irradiation experiments on bare cosmic dust analogs have been scarce up to now. Aims: Our goal is to study the effects of hard X-rays on cosmic dust analogs via in situ X-ray diffraction. By using a hard X-ray synchrotron nanobeam, we seek to simulate cumulative X-ray exposure on dust grains during their lifetime in these astrophysical environments and provide an upper limit on the effect of hard X-rays on dust grain structure. Methods: We prepared enstatite (MgSiO3) nanograins, which are analogs to cosmic silicates, via the melting-quenching technique. These amorphous grains were then annealed to obtain polycrystalline grains. These were characterized via scanning electron microscopy (SEM) and high-resolution transmission electron microscopy (HRTEM) before irradiation. Powder samples were prepared in X-ray transparent substrates and were irradiated with hard X-rays nanobeams (29.4 keV) provided by beamline ID16B of the European Synchrotron Radiation Facility (Grenoble). X-ray diffraction images were recorded in transmission mode, and the ensuing diffractograms were analyzed as a function of the total X-ray exposure time. Results: We detected the amorphization of polycrystalline silicates embedded in an organic matrix after an accumulated X-ray exposure of 6.4 × 1027 eV cm-2. Pure crystalline silicate grains (without resin) do not exhibit amorphization. None of the amorphous silicate samples (pure and embedded in resin) underwent crystallization. We analyze the evolution of the polycrystalline sample embedded in an organic matrix as a function of X-ray exposure. Conclusions: Loss of diffraction peak intensity, peak broadening, and the disappearance of discrete spots and arcs reveal the amorphization

  19. Novel X-ray Communication Based XNAV Augmentation Method Using X-ray Detectors

    Directory of Open Access Journals (Sweden)

    Shibin Song

    2015-09-01

    Full Text Available The further development of X-ray pulsar-based NAVigation (XNAV is hindered by its lack of accuracy, so accuracy improvement has become a critical issue for XNAV. In this paper, an XNAV augmentation method which utilizes both pulsar observation and X-ray ranging observation for navigation filtering is proposed to deal with this issue. As a newly emerged concept, X-ray communication (XCOM shows great potential in space exploration. X-ray ranging, derived from XCOM, could achieve high accuracy in range measurement, which could provide accurate information for XNAV. For the proposed method, the measurement models of pulsar observation and range measurement observation are established, and a Kalman filtering algorithm based on the observations and orbit dynamics is proposed to estimate the position and velocity of a spacecraft. A performance comparison of the proposed method with the traditional pulsar observation method is conducted by numerical experiments. Besides, the parameters that influence the performance of the proposed method, such as the pulsar observation time, the SNR of the ranging signal, etc., are analyzed and evaluated by numerical experiments.

  20. Novel X-ray Communication Based XNAV Augmentation Method Using X-ray Detectors.

    Science.gov (United States)

    Song, Shibin; Xu, Luping; Zhang, Hua; Bai, Yuanjie

    2015-09-03

    The further development of X-ray pulsar-based NAVigation (XNAV) is hindered by its lack of accuracy, so accuracy improvement has become a critical issue for XNAV. In this paper, an XNAV augmentation method which utilizes both pulsar observation and X-ray ranging observation for navigation filtering is proposed to deal with this issue. As a newly emerged concept, X-ray communication (XCOM) shows great potential in space exploration. X-ray ranging, derived from XCOM, could achieve high accuracy in range measurement, which could provide accurate information for XNAV. For the proposed method, the measurement models of pulsar observation and range measurement observation are established, and a Kalman filtering algorithm based on the observations and orbit dynamics is proposed to estimate the position and velocity of a spacecraft. A performance comparison of the proposed method with the traditional pulsar observation method is conducted by numerical experiments. Besides, the parameters that influence the performance of the proposed method, such as the pulsar observation time, the SNR of the ranging signal, etc., are analyzed and evaluated by numerical experiments.

  1. Combinatorial Screening of Advanced Scintillators for High Resolution X-ray Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Shifan; Tao, Dejie; Lynch, Michael; Yuan, Xianglong; Li, Yiqun

    2008-05-12

    The lack of efficient scintillators is a major problem for developing powerful x-ray detectors that are widely used in homeland security, industrial and scientific research. Intematix has developed and applied a high throughput screening process and corresponding crystal growth technology to significantly speed up the discovery process for new efficient scintillators. As a result, Intematix has invented and fabricated three new scintillators both in powder and bulk forms, which possess promising properties such as better radiation hardness and better matching for silicon diode.

  2. X-Ray Polarimetry

    CERN Document Server

    Kaaret, Philip

    2014-01-01

    We review the basic principles of X-ray polarimetry and current detector technologies based on the photoelectric effect, Bragg reflection, and Compton scattering. Recent technological advances in high-spatial-resolution gas-filled X-ray detectors have enabled efficient polarimeters exploiting the photoelectric effect that hold great scientific promise for X-ray polarimetry in the 2-10 keV band. Advances in the fabrication of multilayer optics have made feasible the construction of broad-band soft X-ray polarimeters based on Bragg reflection. Developments in scintillator and solid-state hard X-ray detectors facilitate construction of both modular, large area Compton scattering polarimeters and compact devices suitable for use with focusing X-ray telescopes.

  3. Temporal artifacts in flat dynamic x-ray detectors

    Science.gov (United States)

    Overdick, Michael; Solf, Torsten; Wischmann, Hans-Aloys

    2001-06-01

    Flat X-ray detectors based on CsI:Tl scintillators and amorphous silicon photodiodes are known to exhibit temporal artefacts (ghost images) which decay over time. Previously, these temporal artefacts have been attributed mainly to residual signals from the amorphous silicon photodiodes. More detailed experiments presented here show that a second class of effects, the so-called gain effects, also contributes significantly to the observed temporal artefacts. Both the residual signals and the photodiode gain effect have been characterized under various exposure conditions in the study presented here. The results of the experiments quantitatively show the decay of the temporal artefacts. Additionally, the influence of the detector's reset light on both effects in the photodiode has been studied in detail. The data from the measurements is interpreted based on a simple trapping model which suggests a strong link between the photodiode residual signals and the photodiode gain effect. For the residual signal effect a possible correction scheme is described. Furthermore, the relevance of the remaining temporal artefacts for the applications is briefly discussed for both the photodiode residual signals and the photodiode gain effect.

  4. Infrared identification of hard X-ray sources in the Galaxy

    CERN Document Server

    Gómez-Morán, A Nebot; Pineau, F -X; Carrera, F J; Pakull, M W; Riddick, F

    2015-01-01

    The nature of the low- to intermediate-luminosity (Lx$\\,\\sim 10^{32-34}$ erg s$^{-1}$) source population revealed in hard band (2-10 keV) X-ray surveys of the Galactic Plane is poorly understood. To overcome such problem we cross-correlated the XMM-Newton 3XMM-DR4 survey with the infrared 2MASS and GLIMPSE catalogues. We identified reliable X-ray-infrared associations for 690 sources. We selected 173 sources having hard X-ray spectra, typical of hard X-ray high-mass stars (kT$\\,>\\,5\\,$keV), and 517 sources having soft X-ray spectra, typical of active coronae. About $18\\,\\%$ of the soft sources are classified in the literature: $\\sim\\,91\\%$ as stars, with a minor fraction of WR stars. Roughly $15\\,\\%$ of the hard sources are classified in the literature: $\\sim\\,68\\%$ as high-mass X-ray stars single or in binary systems (WR, Be and HMXBs), with a small fraction of G and B stars. We carried out infrared spectroscopic pilot observations at the William Herschel Telescope for five hard X-ray sources. Three of them ...

  5. H-alpha and hard X-ray development in two-ribbon flares

    Science.gov (United States)

    Dwivedi, B. N.; Hudson, H. S.; Kane, S. R.; Svestka, Z.

    1984-01-01

    Morphological features of two-ribbon flares have been studied, using simultaneous ISEE-3 hard X-ray records and high-resolution Big Bear H-alpha movies for more than 20 events. Long-lasting and complex hard X-ray bursts are almost invariably found associated with flares of the two-ribbon type. At least three events are found, namely March 31, 1979, April 10, 1980, and July 1, 1980, where the occurrence of individual spikes in hard X-ray radiation coincides with suddenly enhanced H-alpha emission covering the sunspot penumbra. There definitely exist important (greater than or equal to 1 B) two-ribbon flares without significant hard X-ray emission.

  6. Hard X-rays for processing hybrid organic-inorganic thick films.

    Science.gov (United States)

    Jiang, Yu; Carboni, Davide; Pinna, Alessandra; Marmiroli, Benedetta; Malfatti, Luca; Innocenzi, Plinio

    2016-01-01

    Hard X-rays, deriving from a synchrotron light source, have been used as an effective tool for processing hybrid organic-inorganic films and thick coatings up to several micrometres. These coatings could be directly modified, in terms of composition and properties, by controlled exposure to X-rays. The physico-chemical properties of the coatings, such as hardness, refractive index and fluorescence, can be properly tuned using the interaction of hard X-rays with the sol-gel hybrid films. The changes in the microstructure have been correlated especially with the modification of the optical and the mechanical properties. A relationship between the degradation rate of the organic groups and the rise of fluorescence from the hybrid material has been observed; nanoindentation analysis of the coatings as a function of the X-ray doses has shown a not linear dependence between thickness and film hardness.

  7. Hard X-ray emission spectroscopy with pink beam

    Energy Technology Data Exchange (ETDEWEB)

    Kvashnina, Kristina O.; Rossberg, Andre; Exner, Joerg; Scheinost, Andreas C. [Helmholtz-Zentrum Dresden-Rossendorf e.V., Dresden (Germany). Molecular Structures

    2017-06-01

    Valence-band X-ray emission spectroscopy (XES) with a ''pink beam'', i.e. a beam with large energy bandwidth produced by a double-multilayer monochromator, is introduced here to overcome the weak count rate of monochromatic beams produced by conventional double-crystal monochromators. Our results demonstrate that - in spite of the large bandwidth in the order of 100 eV - the high spectral resolution of the Johann-type spectrometer is maintained, while the two orders of magnitude higher flux greatly reduces the required counting time. The short working distance Johann-type X-ray emission spectrometer and multilayer monochromator is available at ROBL.

  8. Incoherent Diffractive Imaging via Intensity Correlations of Hard X Rays

    Science.gov (United States)

    Classen, Anton; Ayyer, Kartik; Chapman, Henry N.; Röhlsberger, Ralf; von Zanthier, Joachim

    2017-08-01

    Established x-ray diffraction methods allow for high-resolution structure determination of crystals, crystallized protein structures, or even single molecules. While these techniques rely on coherent scattering, incoherent processes like fluorescence emission—often the predominant scattering mechanism—are generally considered detrimental for imaging applications. Here, we show that intensity correlations of incoherently scattered x-ray radiation can be used to image the full 3D arrangement of the scattering atoms with significantly higher resolution compared to conventional coherent diffraction imaging and crystallography, including additional three-dimensional information in Fourier space for a single sample orientation. We present a number of properties of incoherent diffractive imaging that are conceptually superior to those of coherent methods.

  9. Advances in the development of encapsulants for mercuric iodide X-ray detectors

    OpenAIRE

    Iwanczyk, J. S.; Wang, Y.J.; Bradley, J. G.; Albee, A. L.; Schnepple, W. F.

    1990-01-01

    Advances in the development of protective impermeable encapsulants with high transparency to ultra-low-energy X-rays for use on HgI_2 X-ray detectors are reported. Various X-ray fluorescence spectra from coated detectors are presented. The X-ray absorption in the encapsulants has been analyzed using characteristic radiation from various elements. Results suggest that low-energy cutoffs for the detectors are not determined solely by the encapsulating coatings presently employed but are also in...

  10. Flux monitoring hard X-ray optics in a single electrode configuration

    CERN Document Server

    Stoupin, Stanislav; Katsoudas, John

    2014-01-01

    To explore possibilities for X-ray flux monitoring on optical elements electrical responses of silicon and diamond single crystals and that of an X-ray mirror were studied under exposure to hard X-rays in a single electrode configuration in ambient air. To introduce flux monitoring as a non-invasive capability a platinum electrode was deposited on a small unexposed portion of the entrance surface of the crystals while for the X-ray mirror the entire mirror surface served as an electrode. It was found that the electrical responses are affected by photoemission and photoionization of the surrounding air. The influence of these factors was quantified using estimations of total electron yield and the ionization current. It is shown that both phenomena can be used for the non-invasive monitoring of hard X-ray flux on the optical elements. Relevant limits of applicability such as detection sensitivity and charge collection efficiency are identified and discussed.

  11. Nonthermal Hard X-Ray Emission from the Galactic Ridge

    OpenAIRE

    Dogiel, V. A.; Schoenfelder, V.; Strong, A.W.

    2001-01-01

    We investigate the origin of the nonthermal X-ray emission from the Galactic ridge in the range 10-200 keV. We consider bremsstrahlung of subrelativistic cosmic ray protons and electrons as production processes. From the solution of the kinetic equations describing the processes of particle in-situ acceleration and spatial propagation we derive parameters of the spectra for protons and electrons. For in-situ acceleration the flux of accelerated particles consists mainly of protons since the r...

  12. Development of thermally formed glass optics for astronomical hard X-ray telescopes

    DEFF Research Database (Denmark)

    Craig, W.W.; Hailey, C.J.; Jimenez-Garate, M.

    2000-01-01

    The next major observational advance in hard X-ray/soft gamma-ray astrophysics will come with the implementation of telescopes capable of focusing 10-200 keV radiation. Focusing allows high signal-to-noise imaging and spectroscopic observations of many sources in this band for the first time. The...... report on new, thermally-formed glass micro-sheet optics capable of meeting the requirements of the next-generation of astronomical hard X-ray telescopes....

  13. Surface roughness-aided hard X-ray emission from carbon nanotubes

    Indian Academy of Sciences (India)

    Suman Bagchi; P Prem Kiran; M K Bhuyan; M Krishnamurthy; K Yang; A M Rao; G Ravindra Kumar

    2010-12-01

    Efficient low debris hard X-ray source based on multiwalled carbon nanotubes (MWNT) irradiated by intense, femtosecond laser over an intensity range of 1015 –1017 W cm−2 2 is reported. The MWNT targets yield two orders of magnitude higher X-rays (indicating significant enhancement of laser coupling) and three orders of magnitude lower debris compared to conventional metallic targets under identical experimental conditions. The simple analytical model explains the basic experimental observations and also serves as a guide to design efficient targets to achieve low-debris laser plasma-based hard X-ray sources at low laser intensities suitable for multi-kHz operation.

  14. Design of grazing-incidence multilayer supermirrors for hard-X-ray reflectors

    DEFF Research Database (Denmark)

    Joensen, K. D.; Voutov, P.; Szentgyorgyi, A.;

    1995-01-01

    Extremely broadband grazing-incidence multilayers for hard-X-ray reflection can be obtained by a gradual change of the layer thicknesses down through the structure. Existing approaches for designing similar neutron optics, called supermirrors, are shown to provide respectable performance when app......-X-ray reflector and a hard-X-ray telescope) shows that an improved performance can be obtained. A multilayer whose bilayer thicknesses are given by a power law expression is found to provide the best solution; however, it is only slightly better than some of the adapted neutron designs...

  15. The BeppoSAX High Energy Large Area Survey. IV. On the soft X-ray properties of the hard X-ray-selected HELLAS sources

    CERN Document Server

    Vignali, C; Fiore, F; La Franca, F

    2001-01-01

    We present a comprehensive study of the soft X-ray properties of the BeppoSAX High-Energy Large Area Survey (HELLAS) sources. A large fraction (about 2/3) of the hard X-ray selected sources is detected by ROSAT. The soft X-ray colors for many of these objects, along with the 0.5-2 keV flux upper limits for those undetected in the ROSAT band, do imply the presence of absorption. The comparison with the ROSAT Deep Survey sources indicates that a larger fraction of absorbed objects among the HELLAS sources is present, in agreement with their hard X-ray selection and the predictions of the X-ray background synthesis models. Another striking result is the presence of a soft (additional) X-ray component in a significant fraction of absorbed objects.

  16. Hard X-ray Emission along the Z Track in GX 17+2

    Indian Academy of Sciences (India)

    G. Q. Ding; C. P. Huang

    2015-09-01

    Using the data from the Proportional Counter Array (PCA) and the High-Energy X-ray Timing Experiment (HEXTE) on board Rossi X-Ray Timing Explorer for Z source GX 17+2, we investigate the evolution of its PCA spectra and HEXTE spectra along a `Z’ track on its hardness-intensity diagram. A hard X-ray tail is detected in the HEXTE spectra. The detected hard X-ray tails are discontinuously scattered throughout the Z track. The found hard X-ray tail hardens from the horizontal branch, through the normal branch, to the flaring branch in principle and it contributes ∼ (20–50)% of the total flux in 20–200 keV. Our joint fitting results of the PCA+HEXTE spectra in 3–200 keV show that the portion of Comptonization in the Bulk-Motion Comptonization (BMC) model accounts for the hard X-ray tail, which indicates that the BMC process could be responsible for the detected hard tail. The temperature of the seed photons for BMC is ∼ 2.7 keV, implying that these seed photons might be emitted from the surface of the neutron star (NS) or the boundary layer between the NS and the disk and, therefore, this process could take place around the NS or in the boundary layer.

  17. Development of a hard x-ray focal plane compton polarimeter: a compact polarimetric configuration with scintillators and Si photomultipliers

    Science.gov (United States)

    Chattopadhyay, T.; Vadawale, S. V.; Goyal, S. K.; Mithun, N. P. S.; Patel, A. R.; Shukla, R.; Ladiya, T.; Shanmugam, M.; Patel, V. R.; Ubale, G. P.

    2016-02-01

    X-ray polarization measurement of cosmic sources provides two unique parameters namely degree and angle of polarization which can probe the emission mechanism and geometry at close vicinity of the compact objects. Specifically, the hard X-ray polarimetry is more rewarding because the sources are expected to be intrinsically highly polarized at higher energies. With the successful implementation of Hard X-ray optics in NuSTAR, it is now feasible to conceive Compton polarimeters as focal plane detectors. Such a configuration is likely to provide sensitive polarization measurements in hard X-rays with a broad energy band. We are developing a focal plane hard X-ray Compton polarimeter consisting of a plastic scintillator as active scatterer surrounded by a cylindrical array of CsI(Tl) scintillators. The scatterer is 5 mm diameter and 100 mm long plastic scintillator (BC404) viewed by normal PMT. The photons scattered by the plastic scatterer are collected by a cylindrical array of 16 CsI(Tl) scintillators (5 mm × 5 mm × 150 mm) which are read by Si Photomultiplier (SiPM). Use of the new generation SiPMs ensures the compactness of the instrument which is essential for the design of focal plane detectors. The expected sensitivity of such polarimetric configuration and complete characterization of the plastic scatterer, specially at lower energies have been discussed in [11, 13]. In this paper, we characterize the CsI(Tl) absorbers coupled to SiPM. We also present the experimental results from the fully assembled configuration of the Compton polarimeter.

  18. A large area position sensitive X-ray detector for astrophysical observations

    NARCIS (Netherlands)

    Mels, W.A.; Lowes, P.; Buurmans, H.B.; Brinkman, A.C.; Naber, A.P.; Rook, A.

    1988-01-01

    A large area position sensitive X-ray detector has been developed for use in the coded mask imaging X-ray spectrometer (COMIS) aboard the USSR research module KVANT. The module was launched on March 31, 1987. The detector, having a sensitive area of 256 × 256 mm2, is a sealed multiwire proportional

  19. Simulation of one-dimensionally polarized X-ray semiconductor detectors

    NARCIS (Netherlands)

    Engel, K.J.; Herrmann, C.

    2011-01-01

    Abstract: A pixelated X-ray semiconductor detector (=“direct converter”) is studied which contains an inhomogeneous electric field parallel to the depth axis caused by different concentrations of p- or n-doping. The X-ray energy deposition and charge movement within the detector is modeled in Monte-

  20. Miniaturized X-ray telescope for VZLUSAT-1 nanosatellite with Timepix detector

    Science.gov (United States)

    Baca, T.; Platkevic, M.; Jakubek, J.; Inneman, A.; Stehlikova, V.; Urban, M.; Nentvich, O.; Blazek, M.; McEntaffer, R.; Daniel, V.

    2016-10-01

    We present the application of a Timepix detector on the VZLUSAT-1 nanosatellite. Timepix is a compact pixel detector (256×256 square pixels, 55×55 μm each) sensitive to hard X-ray radiation. It is suitable for detecting extraterrestrial X-rays due to its low noise characteristics, which enables measuring without special cooling. This project aims to verify the practicality of the detector in conjunction with 1-D Lobster-Eye optics to observe celestial sources between 5 and 20 keV. A modified USB interface (developed by IEAP at CTU in Prague) is used for low-level control of the Timepix. An additional 8-bit Atmel microcontroller is dedicated for commanding the detector and to process the data onboard the satellite. We present software methods for onboard post-processing of captured images, which are suitable for implementation under the constraints of the low-powered embedded hardware. Several measuring modes are prepared for different scenarios including single picture exposure, solar UV-light triggered exposure, and long-term all-sky monitoring. The work has been done within Medipix2 collaboration. The satellite is planned for launch in April 2017 as a part of the QB50 project with an end of life expectancy in 2019.

  1. Development of CdZnTe X-ray detectors at DSRI

    DEFF Research Database (Denmark)

    van Pamelen, M.A.J.; Budtz-Jørgensen, Carl; Kuvvetli, Irfan

    2000-01-01

    An overview of the development of CdZnTe X-ray detectors at the Danish Space Research Institute is presented. Initiated in the beginning of 1996, the main motivation at that time was to develop focal plane detectors for the novel type of hard X-ray telescopes, which are currently under study at D...... trapping has now little influence and the spectrum displays a pronounced Gaussian peak at 661 keV with a width (FWHM) of 6.9 keV. Also a small peak produced by CdTe escape events can now be observed. At the same time, no events have to be rejected....... at DSRI. With the advent of the Danish Micro Satellite program it was, however, recognised that this type of detector is very well suited for two proposed missions (eXCALIBur, AXO). The research at DSRI has so far been concentrated on the spectroscopic properties of the CZT detector. At DSRI we have...

  2. The Si/CdTe semiconductor camera of the ASTRO-H Hard X-ray Imager (HXI)

    Science.gov (United States)

    Sato, Goro; Hagino, Kouichi; Watanabe, Shin; Genba, Kei; Harayama, Atsushi; Kanematsu, Hironori; Kataoka, Jun; Katsuragawa, Miho; Kawaharada, Madoka; Kobayashi, Shogo; Kokubun, Motohide; Kuroda, Yoshikatsu; Makishima, Kazuo; Masukawa, Kazunori; Mimura, Taketo; Miyake, Katsuma; Murakami, Hiroaki; Nakano, Toshio; Nakazawa, Kazuhiro; Noda, Hirofumi; Odaka, Hirokazu; Onishi, Mitsunobu; Saito, Shinya; Sato, Rie; Sato, Tamotsu; Tajima, Hiroyasu; Takahashi, Hiromitsu; Takahashi, Tadayuki; Takeda, Shin`ichiro; Yuasa, Takayuki

    2016-09-01

    The Hard X-ray Imager (HXI) is one of the instruments onboard the ASTRO-H mission [1-4] to be launched in early 2016. The HXI is the focal plane detector of the hard X-ray reflecting telescope that covers an energy range from 5 to 80 keV. It will execute observations of astronomical objects with a sensitivity for point sources as faint as 1/100,000 of the Crab nebula at > 10 keV. The HXI camera - the imaging part of the HXI - is realized by a hybrid semiconductor detector system that consists of silicon (Si) and cadmium telluride (CdTe) semiconductor detectors. Here, we present the final design of the HXI camera and report on the development of the flight model. The camera is composed of four layers of Double-sided Silicon Strip Detectors (DSSDs) and one layer of CdTe Double-sided Strip Detector (CdTe-DSD), each with an imaging area of 32 mm×32 mm. The strip pitch of the Si and CdTe sensors is 250 μm, and the signals from all 1280 strips are processed by 40 Application Specified Integrated Circuits (ASICs) developed for the HXI. The five layers of sensors are vertically stacked with a 4 mm spacing to increase the detection efficiency. The thickness of the sensors is 0.5 mm for the Si, and 0.75 mm for the CdTe. In this configuration, soft X-ray photons will be absorbed in the Si part, while hard X-ray photons will go through the Si part and will be detected in the CdTe part. The design of the sensor trays, peripheral circuits, power connections, and readout schemes are also described. The flight models of the HXI camera have been manufactured, tested and installed in the HXI instrument and then on the satellite.

  3. An inexpensive spectroscopic beam monitor for hard X-ray synchrotron applications

    CERN Document Server

    Owens, A; Den Hartog, R; Quarati, F; Webb, A; Welter, E; HASYLAB at DESY, Hamburg, Germany

    2007-01-01

    We describe an inexpensive beam monitor for hard X-ray synchrotron applications which has good spectroscopic abilities and can operate without cooling. The device is centred on an inexpensive, commercial off-the-shelf, large area (1.2 × 1.2 mm2) Si photodiode operated in single counting mode. Measurements carried out at the HASYLAB synchrotron research facility have shown that it is fully spectroscopic across the energy range 8 keV to 100 keV with a measured energy resolution of ~ 1.2 keV FWHM at room temperature. The measured resolutions were found to be the same under pencil-beam and full-area illumination, indicating uniform crystallinity and stoichiometry of the bulk. The low cost, simplicity and performance of the detector make it suitable for a wider range of applications, e.g., in undergraduate laboratory experiments.

  4. Tunable hard X-ray spectrometer utilizing asymmetric planes of a quartz transmission crystal.

    Science.gov (United States)

    Seely, John F; Henins, Albert; Feldman, Uri

    2016-05-01

    A Cauchois type hard x-ray spectrometer was developed that utilizes the (301) diffraction planes at an asymmetric angle of 23.51° to the normal to the surface of a cylindrically curved quartz transmission crystal. The energy coverage is tunable by rotating the crystal and the detector arm, and spectra were recorded in the 8 keV to 20 keV range with greater than 2000 resolving power. The high resolution results from low aberrations enabled by the nearly perpendicular angle of the diffracted rays with the back surface of the crystal. By using other asymmetric planes of the same crystal and rotating to selected angles, the spectrometer can operate with high resolution up to 50 keV.

  5. Preliminary Results for LP VPE X-Ray Detectors

    OpenAIRE

    Adams, R; Bates, R.; Da Via, C.; Johnson, N.P.; O'Shea, V.; Pickford, A.; Raine, C.; Smith, K.

    1997-01-01

    Thick epitaxial layers have been grown using Low Pressure Vapour Phase Epitaxy techniques with low free carrier concentrations . This type of material is attractive as a medium for X-ray detection, because of its high conversion efficiency for X-rays in the medically interesting energy range.

  6. The hard X-ray shortages prompted by the clock bursts in GS 1826--238

    CERN Document Server

    Long, Ji; YuPeng, Chen; Shuang-Nan, Zhang; Diego, Torres F; Peter, Kretschmar; Jian, Li

    2013-01-01

    We report on a study of GS 1826--238 using all available {\\it RXTE} observations, concentrating on the behavior of the hard X-rays during type-I bursts. We find a hard X-ray shortage at 30--50 keV promoted by the shower of soft X-rays coming from type-I bursts. This shortage happens with a time delay after the peak of the soft flux of 3.6 $\\pm$ 1.2 seconds.The behavior of hard X-rays during bursts indicates cooling and reheating of the corona, during which a large amount of energy is required. We speculate that this energy originates from the feedback of the type-I bursts to the accretion process, resulting in a rapid temporary increase of the accretion rate.

  7. A Study of Active Shielding Optimized for 1-80 keV Wide-Band X-ray Detector in Space

    CERN Document Server

    Furuta, Yoshihiro; Hiraga, Junko S; Sasano, Makoto; Murakami, Hiroaki; Nakazawa, Kazuhiro

    2015-01-01

    Active shielding is an effective technique to reduce background signals in hard X-ray detectors and to enable observing darker sources with high sensitivity in space. Usually the main detector is covered with some shield detectors made of scintillator crystals such as BGO (Bi$_4$Ge$_3$O$_{12}$), and the background signals are filtered out using anti-coincidence among them. Japanese X-ray observing satellites "Suzaku" and "ASTRO-H" employed this technique in their hard X-ray instruments observing at > 10 keV. In the next generation X-ray satellites, such as the NGHXT proposal, a single hybrid detector is expected to cover both soft (1-10 keV) and hard (> 10 keV) X-rays for effectiveness. However, present active shielding is not optimized for the soft X-ray band, 1-10 keV. For example, Bi and Ge, which are contained in BGO, have their fluorescence emission lines around 10 keV. These lines appear in the background spectra obtained by ASTRO-H Hard X-ray Imager, which are non-negligible in its observation energy b...

  8. Detectability of rotation-powered pulsars in future hard X-ray surveys

    Institute of Scientific and Technical Information of China (English)

    Wei Wang

    2009-01-01

    Recent INTEGRAL/IBIS hard X-ray surveys have detected about 10 young pulsars.We show hard X-ray properties of these 10 young pulsars,which have a luminosity of 10~(33)-10~(37) erg s~(-1) and a photon index of 1.6-2.1 in the energy range of 20-100 keV.The correlation between X-ray luminosity and spin-down power of L_X∝ L_(sd)~(1.31) suggests that the hard X-ray emission in rotation-powered pulsars is dominated by the pulsar wind nebula (PWN) component.Assuming spectral properties are similar in 20-100keV and 2-10 keV for both the pulsar and PWN components,the hard X-ray luminosity and flux of 39 known young X-ray pulsars and 8 millisecond pulsars are obtained,and a correlation of L_X ∝ L_(sd)~(1.5) is derived.About 20 known young X-ray pulsars and 1 millisecond pulsars could be detected with future INTEGRAL and HXMT surveys.We also carry out Monte Carlo simulations of hard X-ray pulsars in the Galaxy and the Gould Belt,assuming values for the pulsar birth rate,initial position,proper motion velocity,period,and magnetic field distribution and evolution based on observational statistics and the L_X - L_(sd) relations: L_X∝ L_(sd)~(1.31) and L_X∝ L_(sd)~(1.5).More than 40 young pulsars (mostly in the Galactic plane) could be detected after ten years of INTEGRAL surveys and the launch of HXMT.So,the young pulsars would be a significant part of the hard X-ray source population in the sky,and will contribute to unidentified hard X-ray sources in present and future hard X-ray surveys by INTEGRAL and HXMT.

  9. Hard X-rays from NGC 4151: A thermal origin?

    Science.gov (United States)

    Titarchuk, Lev; Mastichiadis, Apostolos

    1994-01-01

    We present a model for explaining the recent combined X-ray and low-energy gamma-ray observations of the Seyfert galaxy NGC 4151. According to this model, soft photons become Comptonized in a hot spot producing simultaneously the low-energy power law as observed by Ginga and the high-energy cutoff observed by the Oriented Scintillation Spectrometer Experiment (OSSE). Implementing recently developed theoretical calculations toward a generalized theory of Comptonization, we were able to find fits to the observations using only two parameters which characterize the physical quantities of the emission region: the plasma cloud optical depth and its temperature. We find that there is no need for additional nonthermal, reflection, or higher temperature thermal components to fit the aforementioned OSSE and Ginga observations. We derive in addition the size of the photon region and the temperature of the upscattered soft photons. We should emphasize, also, that any attempt at fitting only the high-energy parts of the spectrum (photon energies greater than 60 keV) by the Sunyaev & Titarchuk (1980) nonrelativistic Comptonization model leads to an underestimate of the Comptonization parameter y (or, equivalently, to an overestimation of the X-ray power-law spectral slope) and leads, as a result, to incorrect proportions between the low-energy and high-energy parts of the spectrum.

  10. Characterization of intense laser-produced fast electrons using hard x-rays via bremsstrahlung

    Science.gov (United States)

    Sawada, H.; Sentoku, Y.; Bass, A.; Griffin, B.; Pandit, R.; Beg, F.; Chen, H.; McLean, H.; Link, A. J.; Patel, P. K.; Ping, Y.

    2015-11-01

    Energy distribution of high-power, short-pulse laser produced fast electrons was experimentally and numerically studied using high-energy bremsstrahlung x-rays. The hard x-ray photons and escaping electrons from various metal foils, irradiated by the 50 TW Leopard laser at Nevada Terawatt Facility, were recorded with a differential filter stack spectrometer that is sensitive to photons produced by mainly 0.5-2 MeV electrons and an electron spectrometer measuring >2 MeV electrons. The experimental bremsstrahlung and the slope of the measured escaped electrons were compared with an analytic calculation using an input electron spectrum estimated with the ponderomotive scaling. The result shows that the electron spectrum entering a Cu foil could be continuous single slope with the slope temperature of ˜1.5 MeV in the detector range. The experiment and analytic calculation were then compared with a 2D particle-in-cell code, PICLS, including a newly developed radiation transport module. The simulation shows that a two-temperature electron distribution is generated at the laser interaction region, but only the hot component of the fast electrons flow into the target during the interaction because the low energy electron component is trapped by self-generated magnetic field in the preformed plasma. A significant amount of the photons less than 100 keV observed in the experiment could be attributed to the low energy electrons entering the foil a few picoseconds later after the gating field disappears.

  11. The LCLS variable-energy hard X-ray single-shot spectrometer.

    Science.gov (United States)

    Rich, David; Zhu, Diling; Turner, James; Zhang, Dehong; Hill, Bruce; Feng, Yiping

    2016-01-01

    The engineering design, implementation, operation and performance of the new variable-energy hard X-ray single-shot spectrometer (HXSSS) for the LCLS free-electron laser (FEL) are reported. The HXSSS system is based on a cylindrically bent Si thin crystal for dispersing the incident polychromatic FEL beam. A spatially resolved detector system consisting of a Ce:YAG X-ray scintillator screen, an optical imaging system and a low-noise pixelated optical camera is used to record the spectrograph. The HXSSS provides single-shot spectrum measurements for users whose experiments depend critically on the knowledge of the self-amplified spontaneous emission FEL spectrum. It also helps accelerator physicists for the continuing studies and optimization of self-seeding, various improved mechanisms for lasing mechanisms, and FEL performance improvements. The designed operating energy range of the HXSSS is from 4 to 20 keV, with the spectral range of order larger than 2% and a spectral resolution of 2 × 10(-5) or better. Those performance goals have all been achieved during the commissioning of the HXSSS.

  12. Correlation of electron beams and hard x-ray emissions in ISTTOK Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Jakubowski, L.; Malinowski, K.; Sadowski, M.J.; Zebrowski, J.; Rabinski, M.; Jakubowski, M.J. [National Centre for Nuclear Research (NCBJ), Otwock (Poland); Plyusnin, V.V.; Fernandes, H.; Silva, C.; Duarte, P. [Association Euratom/IST, Instituto de Plasmas e Fusao Nuclear, Instituto Superior Tecnico, Lisboa (Portugal)

    2013-11-15

    The paper reports on experimental studies of electron beams in the ISTTOK tokamak, those were performed by means of an improved four-channel detector. The Cherenkov-type detector measuring head was equipped with four radiators made of two types of alumina-nitrate (AlN) poly-crystals: machinable and translucent ones, both of 10 mm in diameter and 2.5 mm in thickness. The movable support that enabled the whole detectors to be placed inside the tokamak vacuum chamber, at chosen positions along the ISTTOK minor radius. Since the electron energy distribution is one of the most important characteristics of tokamak plasmas, the main aim of the study was to perform estimations of an energy spectrum of the recorded electrons. For this purpose the radiators were coated with molybdenum (Mo) layers of different thickness. The technique based on the use of Cherenkov-type detectors enabled the detection of fast electrons (of energy above 66 keV) and determination of their spatial and temporal characteristics in the ISTTOK experiment. Measurements of hard X-rays (HXR), which were emitted during ISTTOK discharges, have also been performed. Particular attention was paid to the correlation measurements of HXR pulses with run-away electron beams. (copyright 2013 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  13. A gas microstrip wide angle X-ray detector for application in synchrotron radiation experiments

    CERN Document Server

    Bateman, J E; Derbyshire, G E; Duxbury, D M; Lipp, J; Mir, J A; Simmons, J E; Spill, E J; Stephenson, R; Dobson, B R; Farrow, R C; Helsby, W I; Mutikainen, R; Suni, I

    2002-01-01

    The Gas Microstrip Detector has counting rate capabilities several orders of magnitude higher than conventional wire proportional counters while providing the same (or better) energy resolution for X-rays. In addition the geometric flexibility provided by the lithographic process combined with the self-supporting properties of the substrate offers many exciting possibilities for X-ray detectors, particularly for the demanding experiments carried out on Synchrotron Radiation Sources. Using experience obtained in designing detectors for Particle Physics we have developed a detector for Wide Angle X-ray Scattering studies. The detector has a fan geometry which makes possible a gas detector with high detection efficiency, sub-millimetre spatial resolution and good energy resolution over a wide range of X-ray energy. The detector is described together with results of experiments carried out at the Daresbury Laboratory Synchrotron Radiation Source.

  14. Hard X-ray identification of Eta Carinae and steadiness close to periastron

    CERN Document Server

    Leyder, Jean-Christophe; Rauw, Gregor; 10.1051/0004-6361/201014316

    2010-01-01

    Context: The colliding-wind binary Eta Car exhibits soft X-ray thermal emission that varies strongly around periastron, and non-thermal emission seen in hard X-rays and gamma-rays. Aims: To definitively identify Eta Car as the source of the hard X-ray emission, to examine how changes in the 2-10 keV band influence changes in the hard X-ray band, and to understand more clearly the mechanisms producing the non-thermal emission using new INTEGRAL observations obtained close to periastron. Methods: A Chandra observation encompassing the ISGRI error circle was analysed, and all other soft X-ray sources (including the outer shell of Eta Car itself) were discarded as likely counter-parts. New hard X-ray images of Eta Car were studied close to periastron, and compared to previous observations far from periastron. Results: The INTEGRAL component, when represented by a power law (with a photon index of 1.8), would produce more emission in the Chandra band than observed from any point source in the ISGRI error circle ap...

  15. Shimming with permanent magnets for the x-ray detector in a hybrid x-ray/ MR system.

    Science.gov (United States)

    Wen, Zhifei; Fahrig, Rebecca; Williams, Scott T; Pelc, Norbert J

    2008-09-01

    In this x-ray/MR hybrid system an x-ray flat panel detector is placed under the patient cradle, close to the MR volume of interest (VOI), where the magnetic field strength is approximately 0.5 T. Immersed in this strong field, several electronic components inside the detector become magnetized and create an additional magnetic field that is superimposed on the original field of the MR scanner. Even after linear shimming, the field homogeneity of the MR scanner remains disrupted by the detector. The authors characterize the field due to the detector with the field of two magnetic dipoles and further show that two sets of permanent magnets (NdFeB) can withstand the main magnetic field and compensate for the nonlinear components of the additional field. The ideal number of magnets and their locations are calculated based on a field map measured with the detector in place. Experimental results demonstrate great promise for this technique, which may be useful in many settings where devices with magnetic components need to be placed inside or close to an MR scanner.

  16. Hard X-ray micro-spectroscopy at Berliner Elektronenspeicherring für Synchrotronstrahlung II

    Science.gov (United States)

    Erko, A.; Zizak, I.

    2009-09-01

    The capabilities of the X-ray beamlines at Berliner Elektronenspeicherring für Synchrotronstrahlung II (BESSY II) for hard X-ray measurements with micro- and nanometer spatial resolution are reviewed. The micro-X-ray fluorescence analysis (micro-XRF), micro-extended X-ray absorption fine structure (micro-EXAFS), micro-X-ray absorption near-edge structure (micro-XANES) as well as X-ray standing wave technique (XSW), X-ray beam induced current (XBIC) in combination with micro-XRF and micro-diffraction as powerful methods for organic and inorganic sample characterization with synchrotron radiation are discussed. Mono and polycapillary optical systems were used for fine X-ray focusing down to 1 µm spot size with monochromatic and white synchrotron radiation. Polycapillary based confocal detection was applied for depth-resolved micro-XRF analysis with a volume resolution down to 3.4 · 10 - 6 mm 3. Standing wave excitation in waveguides was also applied to nano-EXAFS measurements with depth resolution on the order of 1 nm. Several examples of the methods and its applications in material research, biological investigations and metal-semiconductor interfaces analysis are given.

  17. Sapphire hard X-ray Fabry-Perot resonators for synchrotron experiments.

    Science.gov (United States)

    Tsai, Yi Wei; Wu, Yu Hsin; Chang, Ying Yi; Liu, Wen Chung; Liu, Hong Lin; Chu, Chia Hong; Chen, Pei Chi; Lin, Pao Te; Fu, Chien Chung; Chang, Shih Lin

    2016-05-01

    Hard X-ray Fabry-Perot resonators (FPRs) made from sapphire crystals were constructed and characterized. The FPRs consisted of two crystal plates, part of a monolithic crystal structure of Al2O3, acting as a pair of mirrors, for the backward reflection (0 0 0 30) of hard X-rays at 14.3147 keV. The dimensional accuracy during manufacturing and the defect density in the crystal in relation to the resonance efficiency of sapphire FPRs were analyzed from a theoretical standpoint based on X-ray cavity resonance and measurements using scanning electron microscopic and X-ray topographic techniques for crystal defects. Well defined resonance spectra of sapphire FPRs were successfully obtained, and were comparable with the theoretical predictions.

  18. Hard X-Rays from a Complete Sample of the Brightest Ultraluminous Infrared Galaxies

    Science.gov (United States)

    Sanders, David B.

    2003-01-01

    We were awarded 70kS of XMM-Newton spacecraft time using the Epic pn camera to observe three ultraluminous infrared galaxies (ULIGs) in order to measure the spectral shape of their hard X-Ray emission, and to use this information to search for the presence of an highly obscured active galactic nucleus (AGN), and to separate out the contributions from a putative starburst. By observing three objects we hope to be able to better assess the role of AGN in the complete class of ULIGs and therefore to better constrain their contribution to the X-ray background. XMM-Newton was deemed to be better suited to our proposed measurements of ULIGs than the Chandra X-ray observatory due to its larger aperture and better sensitivity to hard (2-10 keV) X-rays.

  19. Impact of a Vertically Polarized Undulator on LCLS Hard X-ray Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, David [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2014-11-14

    The LCLS-II project will install two variable gap, horizontally polarized undulators into the LCLS undulator hall. One undulator is designed to produce soft x-rays spanning an energy range of 200-1250 eV (SXU) while the other is designed for the hard spectral range of 1-25 keV (HXU). The hard x-ray LCLS instruments (X-ray Pump- Probe [XPP], X-ray correlation Spectroscopy [XCS], Coherent X-ray Imaging [CXI], Matter in Extreme Conditions [MEC]) will be repurposed to operate on the HXU line while two new soft x-ray beamlines will be created for the SXU line. An alternate HXU undulator design is being considered that could provide advantages over the present design choice. In particular, the project team is collaborating with Argonne National Laboratory to develop a vertically polarized undulator (VPU). A 1-m prototype VPU device was successfully constructed this year and a full size prototype is in process. A decision to alter the project baseline, which is the construction of a horizontally polarized device, must be made in the coming weeks to not impact the present project schedule. Please note that a change to the soft x-ray undulator is not under discussion at the moment.

  20. A New Gated X-Ray Detector for the Orion Laser Facility

    Energy Technology Data Exchange (ETDEWEB)

    Clark, David D. [Los Alamos National Laboratory; Aragonez, Robert J. [Los Alamos National Laboratory; Archuleta, Thomas N. [Los Alamos National Laboratory; Fatherley, Valerie E. [Los Alamos National Laboratory; Hsu, Albert H. [Los Alamos National Laboratory; Jorgenson, H. J. [Los Alamos National Laboratory; Mares, Danielle [Los Alamos National Laboratory; Oertel, John A. [Los Alamos National Laboratory; Oades, Kevin [Atomic Weapons Establishment; Kemshall, Paul [Atomic Weapons Establishment; Thomas, Philip [Atomic Weapons Establishment; Young, Trevor [Atomic Weapons Establishment; Pederson, Neal [VI Control Systems

    2012-08-08

    Gated X-Ray Detectors (GXD) are considered the work-horse target diagnostic of the laser based inertial confinement fusion (ICF) program. Recently, Los Alamos National Laboratory (LANL) has constructed three new GXDs for the Orion laser facility at the Atomic Weapons Establishment (AWE) in the United Kingdom. What sets these three new instruments apart from the what has previously been constructed for the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) is: improvements in detector head microwave transmission lines, solid state embedded hard drive and updated control software, and lighter air box design and other incremental mechanical improvements. In this paper we will present the latest GXD design enhancements and sample calibration data taken on the Trident laser facility at Los Alamos National Laboratory using the newly constructed instruments.

  1. A new X-ray detector for magnetic circular dichroism experiments

    CERN Document Server

    Bateman, J E; Dudzik, E; Laan, G V D; Lipp, J D; Smith, A D; Stephenson, R

    2001-01-01

    X-ray magnetic circular dichroism (XMCD) studies of magnetic 3d transition metal samples require the recording of high quality absorption scans in high magnetic fields using circularly polarised soft X-rays of energies in the range 0.5-1 keV. A Gas Microstrip Detector is described which permits the option of using the X-ray fluorescence signal instead of the usual electron yield signal.

  2. ASCA observations of deep ROSAT fields V. The X-ray spectrum of hard X-ray selected QSOs

    CERN Document Server

    Pappa, A; Georgantopoulos, I; Griffiths, R E; Boyle, B J; Shanks, T

    2001-01-01

    We present an analysis of the \\rosat and \\asca spectra of 21 broad line AGN (QSOs) with $z\\sim 1$ detected in the 2-10 keV band with the \\asca \\gis. The summed spectrum in the \\asca band is well described by a power-law with $\\Gamma=1.56\\pm0.18$, flatter that the average spectral index of bright QSOs and consistent with the spectrum of the X-ray background in this band. The flat spectrum in the \\asca band could be explained by only a moderate absorption ($\\sim 10^{22} \\rm cm^{-2}$) assuming the typical AGN spectrum ie a power-law with $\\Gamma$=1.9. This could in principle suggest that some of the highly obscured AGN, required by most X-ray background synthesis models, may be associated with normal blue QSOs rather than narrow-line AGN. However, the combined 0.5-8 keV \\asca-\\rosat spectrum is well fit by a power-law of $\\Gamma=1.7\\pm0.2$ with a spectral upturn at soft energies. It has been pointed out that such an upturn may be an artefact of uncertainties in the calibration of the ROSAT or ASCA detectors. Nev...

  3. INTEGRAL detection of a hard X-ray transient in NGC 6440

    DEFF Research Database (Denmark)

    Kuulkers, E.; Bozzo, E.; Bazzano, A.

    2015-01-01

    position is: RA, Dec (J2000) = 267.208, -20.314 degrees, with an error radius of 2.4 arcmin (90% c.l.). Formally, there is no known X-ray source within the error circle, so we label the source as IGR J17488-2018. The hard X-ray transient is detected at a significance of 11 (6.5) sigma on the IBIS...

  4. Characteristics of ultrafast K line hard x-ray source from femtosecond terawatt laser-produced plasma

    Institute of Scientific and Technical Information of China (English)

    陈敏; 陈建文; 高鸿奕; 陆培祥; 徐至展

    2003-01-01

    Theoretical studies and analytical scalings were carried out to find the optimized laser parameters and target conditions so that ultrashort hard x-ray pulses and high x-ray power could be achieved. The dependence of laser intensity and wavelength on the yield of K-shell x-ray emission was studied. We propose an optimal design for a foil target for producing high-yield hard x-ray pulses of customizing duration.

  5. A hard X-ray view of the soft-excess in AGN

    CERN Document Server

    Boissay, Rozenn; Paltani, Stéphane

    2015-01-01

    An excess of X-ray emission below 1 keV, called soft-excess, is detected in a large fraction of Seyfert 1-1.5s. The origin of this feature remains debated, as several models have been suggested to explain it, including warm Comptonization and blurred ionized reflection. In order to constrain the origin of this component, we exploit the different behavior of these models above 10 keV. Ionized reflection covers a broad energy range, from the soft X-rays to the hard X-rays, while Comptonization drops very quickly in the soft X-rays. We present here the results of a study done on 102 Seyfert 1s (Sy 1.0, 1.2, 1.5 and NLSy1) from the Swift/BAT 70-Month Hard X-ray Survey catalog. The joint spectral analysis of Swift/BAT and XMM-Newton data allows a hard X-ray view of the soft-excess that is present in about 80% of the objects of our sample. We discuss how the soft-excess strength is linked to the reflection at high energy, to the photon index of the primary continuum and to the Eddington ratio. In particular, we fin...

  6. A Hard X-Ray Power-Law Spectral Cutoff in Centaurus X-4

    CERN Document Server

    Chakrabarty, Deepto; Grefenstette, Brian W; Psaltis, Dimitrios; Bachetti, Matteo; Barret, Didier; Boggs, Steven E; Christensen, Finn E; Craig, William W; Fuerst, Felix; Hailey, Charles J; Harrison, Fiona A; Kaspi, Victoria A; Miller, Jon M; Nowak, Michael A; Rana, Vikram; Stern, Daniel; Wik, Daniel R; Wilms, Joern; Zhang, William W

    2014-01-01

    The low-mass X-ray binary Cen X-4 is the brightest and closest (<1.2 kpc) quiescent neutron star transient. Previous 0.5-10 keV X-ray observations of Cen X-4 in quiescence identified two spectral components: soft thermal emission from the neutron star atmosphere and a hard power-law tail of unknown origin. We report here on a simultaneous observation of Cen X-4 with NuSTAR (3-79 keV) and XMM-Newton (0.3-10 keV) in 2013 January, providing the first sensitive hard X-ray spectrum of a quiescent neutron star transient. The 0.3-79 keV luminosity was 1.1 x 10^(33) erg/s (for D=1kpc), with around 60 percent in the thermal component. We clearly detect a cutoff of the hard spectral tail above 10 keV, the first time such a feature has been detected in this source class. Comptonization and synchrotron shock origins for the hard X-ray emission are ruled out on physical grounds. However, the hard X-ray spectrum is well fit by a thermal bremsstrahlung model with an 18 keV electron temperature, which can be understood as...

  7. Forecasting methods for occurrence and magnitude of proton storms with solar hard X rays

    Science.gov (United States)

    Garcia, H. A.

    2004-06-01

    A hard X-ray spectrometer (HXRS) was developed jointly by the National Oceanic and Atmospheric Administration (NOAA) Space Environment Center and the Astronomical Institute of the Czech Republic to determine if proton storms could be forecast with greater accuracies than presently available by the existing methods. The HXRS experiment was conceived as a means of proof testing previously discovered empirical relationships between anomalous hard X-ray spectra of hard X-ray flares and solar energetic proton events (SEPs) for space weather forecasting applications. SEPs are showers of highly energetic electrons and ions, mostly protons, that can reach Earth's vicinity within minutes to hours following a moderate to large flare and have the potential of affecting the performance of civilian, military and research satellites as well as certain surface assets. The primary SEP predictor criterion educed during the present study is the requirement that the spectral index, γ, must decline (harden) to at least <=4 for at least 3 min. Flares meeting this criterion have a high association with SEPs. Flares that fail this criterion do not. Other SEP correlative phenomena such as depressed hard X-ray flux and anomalous low temperatures were studied to determine their utility for forecasting purposes. During the study period, March 2000 through December 2002, 107 hard X-ray flares were spectrally analyzed including 16 SEP-associated flares. Fourteen SEP flares were correctly identified, two SEPs were missed, and three false alarms (untrue predictions) were incurred.

  8. X-ray beam splitting design for concurrent imaging at hard X-ray FELs and synchrotron facilities

    Energy Technology Data Exchange (ETDEWEB)

    Oberta, P., E-mail: peter.oberta@rigaku.com [Institute of Physics, Academy of Sciences of the Czech Republic, v.v.i., Na Slovance 2, Praha 8, CZ-18221 (Czech Republic); Rigaku, Novodvorská 994, Praha 4, CZ-14221 (Czech Republic); Mokso, R. [Swiss Light Source, Paul Scherrer Institut, Villigen, CH-5232 Villigen (Switzerland)

    2013-11-21

    A new configuration of diffractive–refractive optics for beam splitting is investigated. The set-up can be applied to perform imaging with two beams simultaneously. It brings advantages toward dynamic studies using image guided diffraction or fluorescence spectroscopy. The optimal energy range of operation for the beam-splitter is between 7 keV and 24 keV, reaching best efficiency at an energy of 10 keV. Due to the long focusing distances (several tens of meters) created by the diffractive–refractive optics and the higher refraction efficiency in the softer energy range, the presented set-ups are ideal for hard X-ray FEL sources.

  9. Relative calibration of energy thresholds on multi-bin spectral x-ray detectors

    Science.gov (United States)

    Sjölin, M.; Danielsson, M.

    2016-12-01

    Accurate and reliable energy calibration of spectral x-ray detectors used in medical imaging is essential for avoiding ring artifacts in the reconstructed images (computed tomography) and for performing accurate material basis decomposition. A simple and accurate method for relative calibration of the energy thresholds on a multi-bin spectral x-ray detector is presented. The method obtains the linear relations between all energy thresholds in a channel by scanning the thresholds with respect to each other during x-ray illumination. The method does not rely on a model of the detector's response function and does not require any identifiable features in the x-ray spectrum. Applying the same method, the offset between the thresholds can be determined also without external stimuli by utilizing the electronic noise as a source. The simplicity and accuracy of the method makes it suitable for implementation in clinical multi-bin spectral x-ray imaging systems.

  10. Development of edgeless TSV X-ray detectors

    Science.gov (United States)

    Sarajlić, M.; Zhang, J.; Pennicard, D.; Smoljanin, S.; Fritzsch, T.; Wilke, M.; Zoschke, K.; Graafsma, H.

    2016-02-01

    We report about the activity and progress on the development of TSV edgeless detectors at DESY. One part of the development is Through Silicon Via (TSV) technology for the Medipix3RX readout chip (ROC). TSV technology is a concept of connecting readout chips to readout electronics. Instead of wire-bonding which introduces a large dead area, TSV enables connection through the ROC itself. By replacing wire-bonding with TSV, the dead space between detector modules will be reduced from around 7 mm to only 1.6 mm. The thickness of the wafer will be 200 μ m, with a via diameter of 60 μ m. Inside of the via, a 5 μ m thick copper layer will be used as a conducting layer. On the back side of the chip a Redistribution Layer (RDL) will be deposited. For the RDL structure, 5 μ m thick copper with 40 μ m wide conductive lines will be used. Bump bonding of the sensor plus ROC assembly to ceramic readout board will be optimized in terms of material and bonding temperature. The second part of the project is the development of the edgeless sensor units using active edge sensor technology. Active edge sensors have been simulated with Synopsys TCAD for different polarities including p-on-n, p-on-p, n-on-p and n-on-n with p-spray or p-stop for different thicknesses from 150 μ m to 500 μ m. Results show that the bending of the electric field close to the active edge is leading to image distortion on the sensor edge. In addition, the current design of active-edge sensors shows very poor radiation hardness. We are currently working on the development of a radiation hard active-edge sensor with optimized imaging quality. The final goal of this development is to make Large Area Medipix Detector (LAMBDA) with TSV edgeless units.

  11. Application of SOI Area Detectors to Synchrotron Radiation X-ray Experiments

    CERN Document Server

    Hashimoto, Ryo; Kumai, Reiji; Kishimoto, Shunji

    2015-01-01

    Application of new detectors using Silicon-On-Insulator (SOI) technology has been started in the Photon Factory, KEK. This project has two purposes. The first purpose is to develop a pulse-counting-type X-ray detector which can be used in synchrotron soft X-ray experiments. The second one is to apply the SOI area detector developed by RIKEN, SOPHIAS, to X-ray diffraction and small-angle scattering experiments in Photon Factory. In this paper, we introduce the current status of our project.

  12. Study on data acquisition circuit used in SSPA linear array detector X-ray detection

    CERN Document Server

    Wei Biao; Che Zhen Ping

    2002-01-01

    After SSPA used as X-ray array detector is developed, the authors take a research on the data acquisition circuit applied to the detector. The experiment designed has verified the feasibility of application of this array detector and its data acquisition circuit to X-ray computed tomography (X-CT). The preliminary test results indicate that the method of the X-ray detection is feasible for industry X-CT nondestructive testing, which brings about advantage for detecting and measuring with high resolution, good efficiency and low cost

  13. Sensitive X-ray detectors made of methylammonium lead tribromide perovskite single crystals

    NARCIS (Netherlands)

    Wei, Haotong; Fang, Yanjun; Mulligan, Padhraic; Chuirazzi, William; Fang, Hong-Hua; Wang, Congcong; Ecker, Benjamin R.; Gao, Yongli; Loi, Maria Antonietta; Cao, Lei; Huang, Jinsong

    2016-01-01

    The large mobilities and carrier lifetimes of hybrid perovskite single crystals and the high atomic numbers of Pb, I and Br make them ideal for X-ray and gamma-ray detection. Here, we report a sensitive X-ray detector made of methylammonium lead bromide perovskite single crystals. A record-high mobi

  14. Sensitive X-ray detectors made of methylammonium lead tribromide perovskite single crystals

    NARCIS (Netherlands)

    Wei, Haotong; Fang, Yanjun; Mulligan, Padhraic; Chuirazzi, William; Fang, Hong-Hua; Wang, Congcong; Ecker, Benjamin R.; Gao, Yongli; Loi, Maria Antonietta; Cao, Lei; Huang, Jinsong

    2016-01-01

    The large mobilities and carrier lifetimes of hybrid perovskite single crystals and the high atomic numbers of Pb, I and Br make them ideal for X-ray and gamma-ray detection. Here, we report a sensitive X-ray detector made of methylammonium lead bromide perovskite single crystals. A record-high mobi

  15. Energy-resolved X-ray detectors: the future of diagnostic imaging

    Directory of Open Access Journals (Sweden)

    Pacella D

    2015-01-01

    Full Text Available Danilo Pacella ENEA-Frascati, Rome, Italy Abstract: This paper presents recent progress in the field of X-ray detectors, which could play a role in medical imaging in the near future, with special attention to the new generation of complementary metal-oxide semiconductor (C-MOS imagers, working in photon counting, that opened the way to the energy-resolved X-ray imaging. A brief description of the detectors used so far in medical imaging (photographic films, imaging plates, flat panel detectors, together with the most relevant imaging quality parameters, shows differences between, and advantages of these new C-MOS imagers. X-ray energy-resolved imaging is very attractive not only for the increase of contrast but even for the capability of detecting the nature and composition of the material or tissue to be investigated. Since the X-ray absorption coefficients of the different parts or organs of the patient (object are strongly dependent on the X-ray photon energy, this multienergy ("colored" X-ray imaging could increase enormously the probing capabilities. While dual-energy imaging is now a reality in medical practice, multienergy is still in its early stage, but a promising research activity. Based on this new technique of color X-ray imaging, the entire scheme of source–object–detector could be revised in the future, optimizing spectrum and detector to the nature and composition of the target to be investigated. In this view, a transition to a set of monoenergetic X-ray lines, suitably chosen in energy and intensity, could be envisaged, instead of the present continuous spectra. Keywords: X-ray detectors, X-ray medical imaging, C-MOS imagers, dual and multienergy CT

  16. Simulation of medical irradiation and X-ray detector signals

    Energy Technology Data Exchange (ETDEWEB)

    Kreisler, Bjoern

    2010-02-08

    -Carlo simulation of the irradiation head of the medical linear accelerator is constructed for the irradiation with electrons and photons in the second part of this thesis. The simulation is validated by comparison with water phantom measurements. Available information from the measurements is limited to the depth dose deposition and dose profiles in selected water depths. The simulation allows the evaluation of dose depositions and spectral particle distributions at various locations. In the electron irradiation mode, a collimation close to the patient is performed by an electron applicator. A possible reduction of the side leakage is evaluated by optimising the collimation of the beam. Medical irradiation with MeV-electrons and X-ray photons is the part of the clinical tumour treatment which is evaluated in this work. (orig.)

  17. CORRELATION OF HARD X-RAY AND WHITE LIGHT EMISSION IN SOLAR FLARES

    Energy Technology Data Exchange (ETDEWEB)

    Kuhar, Matej; Krucker, Säm; Battaglia, Marina; Kleint, Lucia; Casadei, Diego [University of Applied Sciences and Arts Northwestern Switzerland, Bahnhofstrasse 6, 5210 Windisch (Switzerland); Oliveros, Juan Carlos Martinez; Hudson, Hugh S. [Space Sciences Laboratory, University of California, Berkeley, CA 94720-7450 (United States)

    2016-01-01

    A statistical study of the correlation between hard X-ray and white light emission in solar flares is performed in order to search for a link between flare-accelerated electrons and white light formation. We analyze 43 flares spanning GOES classes M and X using observations from the Reuven Ramaty High Energy Solar Spectroscopic Imager and Helioseismic and Magnetic Imager. We calculate X-ray fluxes at 30 keV and white light fluxes at 6173 Å summed over the hard X-ray flare ribbons with an integration time of 45 s around the peak hard-X ray time. We find a good correlation between hard X-ray fluxes and excess white light fluxes, with a highest correlation coefficient of 0.68 for photons with energy of 30 keV. Assuming the thick target model, a similar correlation is found between the deposited power by flare-accelerated electrons and the white light fluxes. The correlation coefficient is found to be largest for energy deposition by electrons above ∼50 keV. At higher electron energies the correlation decreases gradually while a rapid decrease is seen if the energy provided by low-energy electrons is added. This suggests that flare-accelerated electrons of energy ∼50 keV are the main source for white light production.

  18. Correlation of hard X-ray and white light emission in solar flares

    CERN Document Server

    Kuhar, Matej; Oliveros, Juan Carlos Martínez; Battaglia, Marina; Kleint, Lucia; Casadei, Diego; Hudson, Hugh S

    2015-01-01

    A statistical study of the correlation between hard X-ray and white light emission in solar flares is performed in order to search for a link between flare-accelerated electrons and white light formation. We analyze 43 flares spanning GOES classes M and X using observations from RHESSI (Reuven Ramaty High Energy Solar Spectroscopic Imager) and HMI (Helioseismic and Magnetic Imager). We calculate X-ray fluxes at 30 keV and white light fluxes at 6173 \\r{A} summed over the hard X-ray flare ribbons with an integration time of 45 seconds around the peak hard-X ray time. We find a good correlation between hard X-ray fluxes and excess white light fluxes, with a highest correlation coefficient of 0.68 for photons with energy of 30 keV. Assuming the thick target model, a similar correlation is found between the deposited power by flare-accelerated electrons and the white light fluxes. The correlation coefficient is found to be largest for energy deposition by electrons above ~50 keV. At higher electron energies the co...

  19. Intercalibration of the hard X-ray spectrometers on the PVO and ICE (ISEE-3) spacecraft

    Science.gov (United States)

    Kane, S. R.; Klebesadel, R. W.; Fenimore, E. E.; Laros, J. G.

    1988-01-01

    The energetic photon spectrometers aboard the ICE and PVO (Pioneer Venus Orbiter) are described briefly, and the procedure for their in-flight calibrations is discussed. Successful intercalibration of these two instruments led to stereoscopic observations of 100 keV-2 MeV photon sources in solar flares and the study of the directivity and height structure of these sources. The impulsive hard X-ray source is found to extend from the chromosphere to the corona, the brightness of the source decreasing rapidly with increase in height above the chromosphere. The analysis so far indicates no systematic directivity for the hard X-ray source. The observations are consistent with energetic electrons accelerated in the corona propagating downward toward the chromosphere. However, when avaraged over the duration of an impulsive hard X-ray flare, the 'beaming' of electrons is found to be small in most flares.

  20. Characterization of an ultrafast Bragg-Switch for shortening hard x-ray pulses

    Science.gov (United States)

    Sander, M.; Koc, A.; Kwamen, C. T.; Michaels, H.; Reppert, A. v.; Pudell, J.; Zamponi, F.; Bargheer, M.; Sellmann, J.; Schwarzkopf, J.; Gaal, P.

    2016-11-01

    We present a nanostructured device that functions as photoacoustic hard x-ray switch. The device is triggered by femtosecond laser pulses and allows for temporal gating of hard x-rays on picosecond (ps) timescales. It may be used for pulse picking or even pulse shortening in 3rd generation synchrotron sources. Previous approaches mainly suffered from insufficient switching contrasts due to excitation-induced thermal distortions. We present a new approach where thermal distortions are spatially separated from the functional switching layers in the structure. Our measurements yield a switching contrast of 14, which is sufficient for efficient hard x-ray pulse shortening. The optimized structure also allows for utilizing the switch at high repetition rates of up to 208 kHz.

  1. Hard X-ray view of microlensing events in RX J1131-1231

    CERN Document Server

    Neronov, A; Walter, R

    2016-01-01

    RX J1131-1231 is a gravitationally lensed system which includes four images of a quasar lensed by an elliptical galaxy. The flux in the individual images is known to be affected by microlensing effect in the visible and X-ray bands. We study the multi-wavelength properties of RX J1131-1231 over a broad energy range, from optical to hard X-ray, during the periods of the microlensing caustic crossings. We aim to constrain the spatial extent of the X-ray emission region at different energies. We combine the data of the source monitoring in the visible band with the X-ray data of the Burst Alert Telescope (BAT) on board of SWIFT satellite and Chandra X-ray observatory. Inspecting the broad band spectrum and lightcurves of the source we identify several microlensing caustic crossing events, and study the details of variability of the source during these events. The caustic crossings of image A on MJD 55150 and 55500 produce strong variations of the overall X-ray flux from the source. In the soft X-ray band, the ca...

  2. Hard X-ray and ultraviolet emission during the 2011 June 7 solar flare

    CERN Document Server

    Inglis, Andrew R

    2013-01-01

    The relationship between X-ray and UV emission during flares, particularly in the context of quasi-periodic pulsations, remains unclear. To address this, we study the X-ray and UV emission during the eruptive flare of 2011 June 7 utilising X-ray imaging from RHESSI and UV 1700A imaging from SDO/AIA. This event is associated with synchronous quasi-periodic pulsations in both the X-ray and UV emission, as well as substantial motion of the hard X-ray footpoints. The motion of the footpoint associated with the left-hand flare ribbon is shown to reverse direction along the flare ribbons on at least two occasions. Over the same time interval, the footpoints also gradually move apart at v ~ 12 km/s. This is consistent with the measured plane-of-sky thermal X-ray source outward velocity of ~ 14 km/s, and matches the gradual outward expansion of the UV ribbons. However, there is no associated short-timescale motion of the UV bright regions. We find that the locations of the brightest X-ray and UV regions are different...

  3. X-ray characterization of CMOS imaging detector with high resolution for fluoroscopic imaging application

    Science.gov (United States)

    Cha, Bo Kyung; Kim, Cho Rong; Jeon, Seongchae; Kim, Ryun Kyung; Seo, Chang-Woo; Yang, Keedong; Heo, Duchang; Lee, Tae-Bum; Shin, Min-Seok; Kim, Jong-Boo; Kwon, Oh-Kyung

    2013-12-01

    This paper introduces complementary metal-oxide semiconductor (CMOS) active pixel sensor (APS)-based X-ray imaging detectors with high spatial resolution for medical imaging application. In this study, our proposed X-ray CMOS imaging sensor has been fabricated by using a 0.35 μm 1 Poly 4 Metal CMOS process. The pixel size is 100 μm×100 μm and the pixel array format is 24×96 pixels, which provide a field-of-view (FOV) of 9.6 mm×2.4 mm. The 14.3-bit extend counting analog-to digital converter (ADC) with built-in binning mode was used to reduce the area and simultaneously improve the image resolution. Both thallium-doped CsI (CsI:Tl) and Gd2O2S:Tb scintillator screens were used as converters for incident X-rays to visible light photons. The optical property and X-ray imaging characterization such as X-ray to light response as a function of incident X-ray exposure dose, spatial resolution and X-ray images of objects were measured under different X-ray energy conditions. The measured results suggest that our developed CMOS-based X-ray imaging detector has the potential for fluoroscopic imaging and cone-beam computed tomography (CBCT) imaging applications.

  4. Weak Hard X-ray Emission from Two Broad Absorption Line Quasars Observed with NuSTAR: Compton-thick Absorption or Intrinsic X-ray Weakness?

    CERN Document Server

    Luo, B; Alexander, D M; Harrison, F A; Stern, D; Bauer, F E; Boggs, S E; Christensen, F E; Comastri, A; Craig, W W; Fabian, A C; Farrah, D; Fiore, F; Fuerst, F; Grefenstette, B W; Hailey, C J; Hickox, R; Madsen, K K; Matt, G; Ogle, P; Risaliti, G; Saez, C; Teng, S H; Walton, D J; Zhang, W W

    2013-01-01

    We present NuSTAR hard X-ray observations of two X-ray weak broad absorption line (BAL) quasars, PG 1004+130 (radio loud) and PG 1700+518 (radio quiet). Many BAL quasars appear X-ray weak, probably due to absorption by the shielding gas between the nucleus and the accretion-disk wind. The two targets are among the optically brightest BAL quasars, yet they are known to be significantly X-ray weak at rest-frame 2-10 keV (16-120 times fainter than typical quasars). We would expect to obtain ~400-600 hard X-ray (>10 keV) photons with NuSTAR, provided that these photons are not significantly absorbed (NH<1E24 cm^{-2}). However, both BAL quasars are only detected in the softer NuSTAR bands (e.g., 4-20 keV) but not in its harder bands (e.g., 20-30 keV), suggesting that either the shielding gas is highly Compton-thick or the two targets are intrinsically X-ray weak. We constrain the column densities for both to be NH~7E24 cm^{-2} if the weak hard X-ray emission is caused by obscuration from the shielding gas. We d...

  5. Full-field hard x-ray microscopy with interdigitated silicon lenses

    CERN Document Server

    Simons, Hugh; Michael-Lindhard, Jonas; Jensen, Flemming; Hansen, Ole; Detlefs, Carsten; Poulsen, Henning Friis

    2015-01-01

    Full-field x-ray microscopy using x-ray objectives has become a mainstay of the biological and materials sciences. However, the inefficiency of existing objectives at x-ray energies above 15 keV has limited the technique to weakly absorbing or two-dimensional (2D) samples. Here, we show that significant gains in numerical aperture and spatial resolution may be possible at hard x-ray energies by using silicon-based optics comprising 'interdigitated' refractive silicon lenslets that alternate their focus between the horizontal and vertical directions. By capitalizing on the nano-manufacturing processes available to silicon, we show that it is possible to overcome the inherent inefficiencies of silicon-based optics and interdigitated geometries. As a proof-of-concept of Si-based interdigitated objectives, we demonstrate a prototype interdigitated lens with a resolution of ~255 nm at 17 keV.

  6. Sub-100 nm hard X-ray microbeam generation with Fresnel zone plate optics

    CERN Document Server

    Takano, H; Takeuchi, A

    2003-01-01

    A hard X-ray focusing test of a Fresnel zone plate has been performed with a synchrotron radiation source at the undulator beamline 20XU of SPring-8. Fresnel zone plate with a radius of 150 mu m, and an outermost zone width of 100 nm was used for the X-ray focusing device. The 248-m-long beamline provides fully coherent illumination for the focusing device. The focused beam evaluated by the knife-edge-scan method and scanning microscope test using test charts. Nearly diffraction- limited focusing with a size of 120 nm was achieved for the first-order diffraction at 10 keV X-ray. Evaluation for the third order diffraction was also performed at 8 keV X-ray, and a focal size of 50 m has been obtained. (author)

  7. Cosmological evolution of supermassive black holes in galactic centers unveiled by hard X-ray observations.

    Science.gov (United States)

    Ueda, Yoshihiro

    2015-01-01

    We review the current understanding of the cosmological evolution of supermassive black holes in galactic centers elucidated by X-ray surveys of active galactic nuclei (AGNs). Hard X-ray observations at energies above 2 keV are the most efficient and complete tools to find "obscured" AGNs, which are dominant populations among all AGNs. Combinations of surveys with various flux limits and survey area have enabled us to determine the space number density and obscuration properties of AGNs as a function of luminosity and redshift. The results have essentially solved the origin of the X-ray background in the energy band below ∼10 keV. The downsizing (or anti-hierarchical) evolution that more luminous AGNs have the space-density peak at higher redshifts has been discovered, challenging theories of galaxy and black hole formation. Finally, we summarize unresolved issues on AGN evolution and prospects for future X-ray missions.

  8. Hard x-ray photoelectron spectroscopy of chalcopyrite solar cell components

    Science.gov (United States)

    Gloskovskii, A.; Jenkins, C. A.; Ouardi, S.; Balke, B.; Fecher, G. H.; Dai, X.-F.; Gruhn, T.; Johnson, B.; Lauermann, I.; Caballero, R.; Kaufmann, C. A.; Felser, C.

    2012-02-01

    Hard x-ray photoelectron spectroscopy is used to examine the partial density of states of Cu(In,Ga)Se2 (CIGSe), a semiconducting component of solar cells. The investigated, thin Cu(In,Ga)Se2 films were produced by multi-stage co-evaporation. Details of the measured core level and valence band spectra are compared to the calculated density of states. The semiconducting type electronic structure of Cu(In,Ga)Se2 is clearly resolved in the hard x-ray photoelectron spectra.

  9. Simulation study of phase retrieval for hard X-ray in-line phase contrast imaging

    Institute of Scientific and Technical Information of China (English)

    YU; Bin; PENG; Xiang; TIAN; Jindong; NIU; Hanben; DIAO; Luh

    2005-01-01

    Two algorithms for the phase retrieval of hard X-ray in-line phase contrast imaging are presented. One is referred to as Iterative Angular Spectrum Algorithm (IASA) and the other is a hybrid algorithm that combines IASA with TIE (transport of intensity equation). The calculations of the algorithms are based on free space propagation of the angular spectrum. The new approaches are demonstrated with numerical simulations. Comparisons with other phase retrieval algorithms are also performed. It is shown that the phase retrieval method combining the IASA and TIE is a promising technique for the application of hard X-ray phase contrast imaging.

  10. Suzaku Detection of Diffuse Hard X-Ray Emission outside Vela X

    OpenAIRE

    Katsuda, Satoru; Mori, Koji; Petre, Robert; Yamaguchi, Hiroya; Tsunemi, Hiroshi; Bocchino, Fabrizio; Bamba, Aya; Miceli, Marco; Hewitt, John W.; Temim, Tea; Uchida, Hiroyuki; Yoshii, Rie

    2011-01-01

    Vela X is a large, 3x2 degrees, radio-emitting pulsar wind nebula (PWN) powered by the Vela pulsar in the Vela supernova remnant. Using four Suzaku/XIS observations pointed just outside Vela X, we find hard X-ray emission extending throughout the fields of view. The hard X-ray spectra are well represented by a power-law. The photon index is measured to be constant at Gamma~2.4, similar to that of the southern outer part of Vela X. The power-law flux decreases with increasing distance from the...

  11. Image-based spectral distortion correction for photon-counting x-ray detectors

    OpenAIRE

    Ding, Huanjun; Molloi, Sabee

    2012-01-01

    Purpose: To investigate the feasibility of using an image-based method to correct for distortions induced by various artifacts in the x-ray spectrum recorded with photon-counting detectors for their application in breast computed tomography (CT).

  12. A CCD area detector for X-ray diffraction under high pressure for rotating anode source

    Indian Academy of Sciences (India)

    Amar Sinha; Alka B Garg; V Vijayakumar; B K Godwal; S K Sikka

    2000-04-01

    Details of a two-dimensional X-ray area detector developed using a charge coupled device, a image intensifier and a fibre optic taper are given. The detector system is especially optimized for angle dispersive X-ray diffraction set up using rotating anode generator as X-ray source. The performance of this detector was tested by successfully carrying out powder X-ray diffraction measurements on various materials such as intermetallics AuIn2, AuGa2, high material Pd and low scatterer adamantane (C10H16) at ambient conditions. Its utility for quick detection of phase transitions at high pressures with diamond anvil cell is demonstrated by reproducing the known pressure induced structural transitions in RbI, KI and a new structural phase transition in AuGa2 above 10 GPa. Various softwares have also been developed to analyze data from this detector.

  13. Hard X-ray polarimetry with Caliste, a high performance CdTe based imaging spectrometer

    CERN Document Server

    Antier, S; Limousin, O; Caroli, E; da Silva, R M Curado; Blondel, C; Chipaux, R; Honkimaki, V; Horeau, B; Laurent, P; Maia, J M; Meuris, A; Del Sordo, S; Stephen, J B

    2015-01-01

    Since the initial exploration of soft gamma-ray sky in the 60's, high-energy celestial sources have been mainly characterized through imaging, spectroscopy and timing analysis. Despite tremendous progress in the field, the radiation mechanisms at work in sources such as neutrons stars and black holes are still unclear. The polarization state of the radiation is an observational parameter which brings key additional information about the physical process. This is why most of the projects for the next generation of space missions covering the tens of keV to the MeV region require a polarization measurement capability. A key element enabling this capability is a detector system allowing the identification and characterization of Compton interactions as they are the main process at play. The hard X-ray imaging spectrometer module, developed in CEA with the generic name of Caliste module, is such a detector. In this paper, we present experimental results for two types of Caliste-256 modules, one based on a CdTe cr...

  14. Evaluation of controlled-drift detectors in X-ray spectroscopic imaging applications.

    Science.gov (United States)

    Castoldi, Andrea; Guazzoni, Chiara; Ozkan, Cigdem; Vedani, Giorgio; Hartmann, Robert; Bjeoumikhov, Aniouar

    2009-06-01

    A detector that looks promising for advanced imaging modalities--such as X-ray absorption contrast imaging, X-ray fluorescence imaging, and diffraction-enhanced imaging--is the controlled-drift detector (CDD). The CDD is a novel two-dimensional X-ray imager with energy resolving capability of spectroscopic quality. It is built on a fully depleted silicon wafer and features fast readout while being operated at or near room temperature. The use of CDDs in the aforementioned applications allows translating these techniques from synchrotron-based experiments to laboratory-size experiments using polychromatic X-ray generators. We have built a dedicated and versatile detection module based on a 36 mm2 CDD chip featuring pixels of 180 x 180 microm 2, and we evaluated the system performance in different X-ray imaging applications both with synchrotron-based experiments and in the laboratory environment.

  15. The low Earth orbit radiation environment and its impact on the prompt background of hard x-ray focusing telescopes

    Science.gov (United States)

    Fioretti, V.; Bulgarelli, A.; Malaguti, G.; Bianchin, V.; Trifoglio, M.; Gianotti, F.

    2012-07-01

    The background minimization is a science-driven necessity in order to reach deep sensitivity levels in the hard X-ray band, one of the key scientific requirements for hard X-ray telescopes (e.g. NuSTAR, ASTRO-H). It requires a careful modeling of the radiation environment and new concepts of shielding systems. We exploit the Bologna Geant4 Multi-Mission Simulator (BoGEMMS) features to evaluate the impact of the Low Earth Orbit (LEO) radiation environment on the prompt background level for a hybrid Si/CdTe soft and hard X-ray detection assembly and a combined active and passive shielding system. For each class of particles, the spectral distribution of the background flux is simulated, exploring the effect of different materials (plastic vs inorganic active scintillator) and configurations (passive absorbers enclosing or surrounded by the active shielding) on the background count rate. While protons are efficiently removed by the active shielding, an external passive shielding causes the albedo electrons and positrons to be the primary source of background. Albedo neutrons are instead weakly interactive with the active shielding, and they cause an intense background level below 10 keV via elastic scattering. The best shielding configuration in terms of background and active shielding count rates is given by an inorganic scintillator placed inside the passive layers, with the addition of passive material to absorb the intense fluorescence lines of the active shielding and avoid escape peaks on the CdTe detector.

  16. Effects of characteristic x rays on the noise power spectra and detective quantum efficiency of photoconductive x-ray detectors.

    Science.gov (United States)

    Zhao, W; Ji, W G; Rowlands, J A

    2001-10-01

    The effects of K fluorescence on the imaging performance of photoconductor-based x-ray imaging systems are investigated. A cascaded linear systems model was developed, where a parallel cascaded process was implemented to take into account the effect of K-fluorescence reabsorption on the modulation transfer function (MTF), noise power spectrum (NPS), and the spatial frequency dependent detective quantum efficiency [DQE(f)] of an imaging system. The investigation was focused on amorphous selenium (a-Se), which is the most highly developed photoconductor material for x-ray imaging. The results were compared to those obtained with Monte Carlo simulation using the same imaging condition and detector parameters, so that the validity of the cascaded linear system model could be confirmed. Our results revealed that K-fluorescence reabsorption in a-Se is responsible for a 18% drop in NPS at high spatial frequencies with an incident x-ray photon energy of E=20 keV (which is just above the K edge of 12.5 keV). When E increases to 60 keV, the effects of K-fluorescence reabsorption on NPS decrease to approximately 12% at high spatial frequencies. Because the high frequency drop is present in both MTF and NPS, the effect of K fluorescence on DQE(f) is minimal, especially for E that is much higher than the K edge. We also applied the cascaded linear system model to a newly developed compound photoconductor, lead iodide (PbI2), and found that at 60 keV there is a high frequency drop in NPS of 19%. The calculated NPS were compared to previously published measurements of PbI2 detectors.

  17. Energy response calibration of photon-counting detectors using x-ray fluorescence: a feasibility study.

    Science.gov (United States)

    Cho, H-M; Ding, H; Ziemer, B P; Molloi, S

    2014-12-07

    Accurate energy calibration is critical for the application of energy-resolved photon-counting detectors in spectral imaging. The aim of this study is to investigate the feasibility of energy response calibration and characterization of a photon-counting detector using x-ray fluorescence. A comprehensive Monte Carlo simulation study was performed using Geant4 Application for Tomographic Emission (GATE) to investigate the optimal technique for x-ray fluorescence calibration. Simulations were conducted using a 100 kVp tungsten-anode spectra with 2.7 mm Al filter for a single pixel cadmium telluride (CdTe) detector with 3 × 3 mm(2) in detection area. The angular dependence of x-ray fluorescence and scatter background was investigated by varying the detection angle from 20° to 170° with respect to the beam direction. The effects of the detector material, shape, and size on the recorded x-ray fluorescence were investigated. The fluorescent material size effect was considered with and without the container for the fluorescent material. In order to provide validation for the simulation result, the angular dependence of x-ray fluorescence from five fluorescent materials was experimentally measured using a spectrometer. Finally, eleven of the fluorescent materials were used for energy calibration of a CZT-based photon-counting detector. The optimal detection angle was determined to be approximately at 120° with respect to the beam direction, which showed the highest fluorescence to scatter ratio (FSR) with a weak dependence on the fluorescent material size. The feasibility of x-ray fluorescence for energy calibration of photon-counting detectors in the diagnostic x-ray energy range was verified by successfully calibrating the energy response of a CZT-based photon-counting detector. The results of this study can be used as a guideline to implement the x-ray fluorescence calibration method for photon-counting detectors in a typical imaging laboratory.

  18. A HARD X-RAY POWER-LAW SPECTRAL CUTOFF IN CENTAURUS X-4

    Energy Technology Data Exchange (ETDEWEB)

    Chakrabarty, Deepto; Nowak, Michael A. [MIT Kavli Institute for Astrophysics and Space Research, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Tomsick, John A.; Boggs, Steven E.; Craig, William W. [Space Sciences Laboratory, University of California, Berkeley, CA 94720 (United States); Grefenstette, Brian W.; Fürst, Felix; Harrison, Fiona A.; Rana, Vikram [Cahill Center for Astronomy and Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Psaltis, Dimitrios [Department of Astronomy, University of Arizona, Tucson, AZ 85721 (United States); Bachetti, Matteo; Barret, Didier [Observatoire Midi-Pyrénées, Université de Toulouse III - Paul Sabatier, F-31400 Toulouse (France); Christensen, Finn E. [Division of Astrophysics, National Space Institute, Technical University of Denmark, DK-2800 Lyngby (Denmark); Hailey, Charles J. [Columbia Astrophysics Laboratory, Columbia University, New York, NY 10027 (United States); Kaspi, Victoria M. [Department of Physics, McGill University, Montreal, PQ H3A 2T8 (Canada); Miller, Jon M. [Department of Astronomy, University of Michigan, Ann Arbor, MI 48109 (United States); Stern, Daniel [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States); Wik, Daniel R.; Zhang, William W. [Astrophysics Science Division, NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Wilms, Jörn, E-mail: deepto@mit.edu [Dr. Karl-Remeis-Sternwarte and Erlangen Centre for Astroparticle Physics, Universität Erlangen-Nürnberg, D-96049 Bamberg (Germany)

    2014-12-20

    The low-mass X-ray binary (LMXB) Cen X-4 is the brightest and closest (<1.2 kpc) quiescent neutron star transient. Previous 0.5-10 keV X-ray observations of Cen X-4 in quiescence identified two spectral components: soft thermal emission from the neutron star atmosphere and a hard power-law tail of unknown origin. We report here on a simultaneous observation of Cen X-4 with NuSTAR (3-79 keV) and XMM-Newton (0.3-10 keV) in 2013 January, providing the first sensitive hard X-ray spectrum of a quiescent neutron star transient. The 0.3-79 keV luminosity was 1.1×10{sup 33} D{sub kpc}{sup 2} erg s{sup –1}, with ≅60% in the thermal component. We clearly detect a cutoff of the hard spectral tail above 10 keV, the first time such a feature has been detected in this source class. We show that thermal Comptonization and synchrotron shock origins for the hard X-ray emission are ruled out on physical grounds. However, the hard X-ray spectrum is well fit by a thermal bremsstrahlung model with kT{sub e} = 18 keV, which can be understood as arising either in a hot layer above the neutron star atmosphere or in a radiatively inefficient accretion flow. The power-law cutoff energy may be set by the degree of Compton cooling of the bremsstrahlung electrons by thermal seed photons from the neutron star surface. Lower thermal luminosities should lead to higher (possibly undetectable) cutoff energies. We compare Cen X-4's behavior with PSR J1023+0038, IGR J18245–2452, and XSS J12270–4859, which have shown transitions between LMXB and radio pulsar modes at a similar X-ray luminosity.

  19. Some future perspectives in soft- and hard- X-ray photoemission

    Energy Technology Data Exchange (ETDEWEB)

    Fadley, Charles S., E-mail: fadley@physics.ucdavis.edu [Department of Physics, University of California Davis, Davis, CA 95616 (United States); Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Nemšák, Slavomir [Department of Physics, University of California Davis, Davis, CA 95616 (United States); Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)

    2014-08-15

    Highlights: • Polarization-dependent differential photoelectric cross sections in valence photoemission. • Bulk electronic structure from hard X-ray angle-resolved photoemission. • Depth-resolved photoemission using standing-wave and total reflection excitation. • Standing-wave ambient-pressure photoemission as a probe of solid–liquid interfaces. • Molecular dissociation dynamics from photoelectron holography with free-electron laser excitation. - Abstract: We discuss several recent developments in photoemission, with comments on their perspectives for the future. These include an adequate allowance for differential cross section effects in core- and valence-angular distributions, as well as more accurate one-step modeling of angle-resolved photoemission (ARPES); the use of higher photon energies from the soft- to hard- X-ray regime to permit probing bulk electronic structure and buried layers and interfaces; extending ARPES into the soft- and hard- X-ray regimes; tailoring the X-ray wave field through X-ray optical effects including standing waves, total reflection, and tuning through resonances; using standing-wave excitation to provide much enhanced depth sensitivity in studying solid/gas and solid/liquid interfaces; and applying photoelectron holography to time-resolved studies of molecular reactions and dissociation. Specific application examples include a magnetic semiconductor, multilayer structures of complex metal oxides, a thin water solution on a metal oxide surface, and a halo-substituted benzene molecule.

  20. Hard X-rays from Ultra-Compact HII Regions in W49A

    CERN Document Server

    Tsujimoto, M; Feigelson, E D; Getman, K V; Broos, P S

    2006-01-01

    We report the Chandra detection of hard X-ray emission from the Welch ring in W49A, an organized structure of ultra-compact (UC) HII regions containing a dozen nascent early-type stars. Two UC HII regions are associated with hard X-ray emission in a deep Advanced CCD Imaging Spectrometer image exposed for 96.7 ks. One of the two X-ray sources has no near-infrared counterpart and is extended by ~5 arcsec, or ~0.3 pc, at a distance of ~11.4 kpc, which is spatially aligned with the cometary radio continuum emission associated with the UC HII region. The X-ray spectrum of the emission, when fit with a thermal model, indicates a heavily absorbed plasma with extinction of \\~5x10^{23}/cm^{2}, temperature of ~7 keV, and X-ray luminosity in the 3.0-8.0 keV band of ~3x10^{33} ergs/s. Both the luminosity and the size of the emission resemble the extended hard emission found in UC HII regions in Sagittarius B2, yet they are smaller by an order of magnitude than the emission found in massive star clusters such as NGC 3603...

  1. Multiple Plasmoid Ejections and Associated Hard X-ray Bursts in the 2000 November 24 Flare

    CERN Document Server

    Nishizuka, N; Asai, A; Shibata, K; 10.1088/0004-637X/711/2/1062

    2013-01-01

    The Soft X-ray Telescope (SXT) on board Yohkoh revealed that the ejection of X-ray emitting plasmoid is sometimes observed in a solar flare. It was found that the ejected plasmoid is strongly accelerated during a peak in the hard X-ray emission of the flare. In this paper we present an examination of the GOES X 2.3 class flare that occurred at 14.51 UT on 2000 November 24. In the SXT images we found multiple plasmoid ejections with velocities in the range of 250-1500 km/s, which showed blob-like or loop-like structures. Furthermore, we also found that each plasmoid ejection is associated with an impulsive burst of hard X-ray emission. Although some correlation between plasmoid ejection and hard X-ray emission has been discussed previously, our observation shows similar behavior for multiple plasmoid ejection such that each plasmoid ejection occurs during the strong energy release of the solar flare. As a result of temperature-emission measure analysis of such plasmoids, it was revealed that the apparent veloc...

  2. MODELING THE THERMAL DIFFUSE SOFT AND HARD X-RAY EMISSION IN M17

    Energy Technology Data Exchange (ETDEWEB)

    Velazquez, P. F.; Rodriguez-Gonzalez, A.; Esquivel, A. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Ap. 70-543, 04510 D.F. (Mexico); Rosado, M. [Instituto de Astronomia, Universidad Nacional Autonoma de Mexico, Ap. 70-248, 04510 D.F. (Mexico); Reyes-Iturbide, J., E-mail: pablo@nucleares.unam.mx, E-mail: ary@nucleares.unam.mx, E-mail: esquivel@nucleares.unam.mx, E-mail: margarit@astro.unam.mx [LATO-DCET/Universidade Estadual de Santa Cruz, Rodovia Jorge Amado, km 16, 45662-000 Ilheus, BA (Brazil)

    2013-04-10

    We present numerical models of very young wind driven superbubbles. The parameters chosen for the simulations correspond to the particular case of the M17 nebula, but are appropriate for any young superbubble in which the wind sources have not completely dispersed their parental cloud. From the simulations, we computed the diffuse emission in the soft ([0.5-1.5] keV) and hard ([1.5-5] keV) X-ray bands. The total luminosity in our simulations agrees with the observations of Hyodo et al., about two orders of magnitude below the prediction of the standard model of Weaver et al.. The difference with respect to the standard (adiabatic) model is the inclusion of radiative cooling, which is still important in such young bubbles. We show that for this type of object the diffuse hard X-ray luminosity is significant compared to that of soft X-rays, contributing as much as 10% of the total luminosity, in contrast with more evolved bubbles where the hard X-ray emission is indeed negligible, being at least four orders of magnitude lower than the soft X-ray emission.

  3. A Sealed, UHV Compatible, Soft X-ray Detector Utilizing Gas Electron Multipliers

    Energy Technology Data Exchange (ETDEWEB)

    Schaknowski, N.A.; Smith, G.

    2009-10-25

    An advanced soft X-ray detector has been designed and fabricated for use in synchrotron experiments that utilize X-ray absorption spectroscopy in the study a wide range of materials properties. Fluorescence X-rays, in particular C{sub K} at 277eV, are converted in a low pressure gas medium, and charge multiplication occurs in two gas electron multipliers, fabricated in-house from glass reinforced laminate, to enable single photon counting. The detector satisfies a number of demanding characteristics often required in synchrotron environments, such as UHV compatibility compactness, long-term stability, and energy resolving capability.

  4. Polarimetry in the hard X-ray domain with INTEGRAL SPI

    Energy Technology Data Exchange (ETDEWEB)

    Chauvin, M.; Roques, J. P.; Jourdain, E. [Université de Toulouse, UPS-OMP, IRAP, Toulouse (France); Clark, D. J., E-mail: maxime.chauvin@irap.omp.eu [Createc Ltd., Unit 8, Derwent Mill Commercial Park, Cockermouth, Cumbria CA13 0HT (United Kingdom)

    2013-06-01

    We present recent improvements in polarization analysis with the INTEGRAL SPI data. The SPI detector plane consists of 19 independent Ge crystals and can operate as a polarimeter. The anisotropy characteristics of Compton diffusions can provide information on the polarization parameters of the incident flux. By including the physics of the polarized Compton process in the instrument simulation, we are able to determine the instrument response for a linearly polarized emission at any position angle. We compare the observed data with the simulation sets by a minimum χ{sup 2} technique to determine the polarization parameters of the source (angle and fraction). We have tested our analysis procedure with Crab Nebula observations and find a position angle similar to those previously reported in the literature, with a comfortable significance. Since the instrument response depends on the incident angle, each exposure in the SPI data requires its own set of simulations, calculated for 18 polarization angles (from 0° to 170° in steps of 10°) and unpolarized emission. The analysis of a large number of observations for a given source, required to obtain statistically significant results, represents a large amount of computing time, but it is the only way to access this complementary information in the hard X-ray regime. Indeed, major scientific advances are expected from such studies since the observational results will help to discriminate between the different models proposed for the high energy emission of compact objects like X-ray binaries and active galactic nuclei or gamma-ray bursts.

  5. Hard X-ray dose intensity and spatial distribution in a plasma focus device using thermoluminescence dosimeters

    Indian Academy of Sciences (India)

    A Kanani; M N Nasrabadi; B Shirani; I Jabbari

    2015-07-01

    In the present study, X-ray emission dose characteristics from a small Mather-type PF device in various pressures of argon as the operating gas were studied. The PF device was powered by a 12 F capacitor at 25 kV charging voltage. Time-integrated hard X-ray (HXR) emission was investigated using thermoluminescence dosimeters (TLDs). These detectors were calibrated with 60Co and 131Cs sources. Twenty-four dosimeters were placed at four different radial distances from the axis of the electrodes at the top of the anode to measure the dose spatial distribution at the top of the anode for different pressures (0.5–1.3 mbar). At each radius, six dosimeters were placed circularly with equal angular intervals on the inner surface of the device chamber. It was found that the optimum pressure for the highest yield of X-ray is 0.9 mbar. The maximum measured dose was 17 mGy per shot at the top of the anode and about 0.5 mGy per shot at 90° with respect to the anode axis. Furthermore, these results showed that the dose at each radius is symmetrical at 360° around the top of the anode, but X-ray distribution follows an anisotropical behaviour. A fast plastic scintillator was also used for time-resolved HXR detection, and a linear relation was observed between the amplitude of the scintillator-PMT signals and TLD responses.

  6. A bright point source of ultrashort hard x-rays from laser bioplasmas

    CERN Document Server

    Krishnamurthy, M; Lad, Amit D; Ahmad, Saima; Narayanan, V; Rajeev, R; Kundu, M; Kumar, G Ravindra; Ray, Krishanu

    2010-01-01

    Micro and nano structures scatter light and amplify local electric fields very effectively. Energy incident as intense ultrashort laser pulses can be converted to x-rays and hot electrons more efficiently with a substrate that suitably modifies the local fields. Here we demonstrate that coating a plain glass surface with a few micron thick layer of an ubiquitous microbe, {\\it Escherichia coli}, catapults the brightness of hard x-ray bremsstrahlung emission (up to 300 keV) by more than two orders of magnitude at an incident laser intensity of 10$^{16}$ W cm$^{-2}$. This increased yield is attributed to the local enhancement of electric fields around individual {\\it E. coli} cells and is reproduced by detailed particle-in-cell (PIC) simulations. This combination of laser plasmas and biological targets can lead to turnkey, multi-kilohertz and environmentally safe sources of hard x-rays.

  7. SIGMA discovery of a transient hard X-ray source in the galactic center region.

    Science.gov (United States)

    Vargas, M.; Goldwurm, A.; Paul, J.; Denis, M.; Borrel, V.; Bouchet, L.; Roques, J. P.; Jourdain, E.; Trudolyubov, S.; Gilfanov, M.; Churazov, E.; Sunyaev, R.; Khavenson, N.; Dyachkov, A.; Novikov, B.; Chulkov, I.

    1996-09-01

    A new X-ray transient source, GRS 1730-312 (=KS 1730-312), was discovered by the hard X-ray/soft γ-ray coded mask telescope SIGMA/GRANAT in the Galactic Center region during observations performed in September 1994. The flare started on September 22 and lasted approximately 3days, during which the source became the brightest object of the region at energies above 35keV. The average 35-200keV spectrum can be described by a power law with photon index of -2.5 or by a thermal bremsstrahlung model with kT_e_=~70keV. SIGMA data have been found consistent with the spectral shape and with the spectral evolution observed by the TTM/Mir-Kvant telescope at lower energies. This new source belongs to the population of hard X-ray sources already detected by SIGMA in the direction of the Galactic Bulge region.

  8. Simultaneous x-ray fluorescence and K-edge CT imaging with photon-counting detectors

    Science.gov (United States)

    Li, Liang; Li, Ruizhe; Zhang, Siyuan; Chen, Zhiqiang

    2016-10-01

    Rapid development of the X-ray phonon-counting detection technology brings tremendous research and application opportunities. In addition to improvements in conventional X-ray imaging performance such as radiation dose utilization and beam hardening correction, photon-counting detectors allows significantly more efficient X-ray fluorescence (XRF) and K-edge imaging, and promises a great potential of X-ray functional, cellular and molecular imaging. XRF is the characteristic emission of secondary X-ray photons from a material excited by initial X-rays. The phenomenon is widely used for chemical and elemental analysis. K-edge imaging identifies a material based on its chemically-specific absorption discontinuity over X-ray photon energy. In this paper, we try to combine XRF and K-edge signals from the contrast agents (e.g., iodine, gadolinium, gold nanoparticles) to simultaneously realize XFCT and K-edge CT imaging for superior image performance. As a prerequisite for this dual-modality imaging, the accurate energy calibration of multi-energy-bin photon-counting detectors is critically important. With the measured XRF data of different materials, we characterize the energy response function of a CZT detector for energy calibration and spectrum reconstruction, which can effectively improve the energy resolution and decrease the inconsistence of the photon counting detectors. Then, a simultaneous K-edge and X-ray fluorescence CT imaging (SKYFI) experimental setup is designed which includes a cone-beam X-ray tube, two separate photon counting detector arrays, a pin-hole collimator and a rotation stage. With a phantom containing gold nanoparticles the two types of XFCT and K-edge CT datasets are collected simultaneously. Then, XFCT and K-edge CT images are synergistically reconstructed in a same framework. Simulation results are presented and quantitative analyzed and compared with the separate XFCT and K-edge CT results.

  9. Technological aspects of GEM detector design and assembling for soft x-ray application

    Science.gov (United States)

    Kowalska-Strzeciwilk, E.; Chernyshova, M.

    2016-09-01

    Various types of Micro Pattern Gas Detectors (MPGDs) found applications as tracking detectors in high energy particle physics experiments and as well as imaging detectors, especially for soft X-rays. These detectors offer several advantages like high count rate capability, good spatial and energy resolution, low cost and possibility of constructing large area detectors with very small dead area. Construction, like the triple Gas Electron Multiplier (GEM) detector has become a standard detector, which is widely used for different imaging applications. Some examples of such applications are: monitoring the impurity in plasma, imaging system for mapping of some parameters like pigment distributions using X-ray fluorescence technique[1], proton range radiography system for quality assurance in hadron therapy. Measuring of the Soft X-Ray (SXR) radiation of magnetic fusion plasma is a standard way of accessing valuable information, for example, about particle transport and MHD. The paper is focused on the design of GEM based soft Xray radiation detecting system which is under development. It is dedicated to study soft X-ray emission of plasma radiation with focus on tungsten emission lines energy region. The paper presents the designing, construction and assembling of a prototype of two triple-GEM detectors for soft-X ray application on the WEST device.

  10. The use of CdTe detectors for dental X-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcus Aurelio P. dos; Fragoso, Maria da Conceicao F.; Oliveira, Mercia L.; Lima, Ricardo de A.; Hazin, Clovis A. [Centro Regional de Ciencias Nucleares (CRCN/CNEN-PE), Recife, PE (Brazil)]. E-mails: masantos@cnen.gov.br; mariacc05@yahoo.com.br; mercial@cnen.gov.br; ralima@cnen.gov.br; chazin@cnen.gov.br

    2007-07-01

    he cadmium telluride (CdTe) semiconductor detector provides high detection efficiency for use in the diagnostic x-rays energy range, because of the high atomic number and high density of the crystal. Moreover, it has the great advantage of working at room temperature, in contrast to the germanium detector, which operates in liquid nitrogen temperature. The CdTe detector has been utilized in diagnostic x-ray spectroscopy, but only scarce information about its use in dental X-ray beams has been published. In this way, a portable 3x3x1 mm{sup 3} CdTe solid state detector (XR-100T CdTe by Amptek, Inc.) with tungsten pinhole collimators, alignment device and associated software was utilized in this work for measuring the photon spectra in the dental x-ray kVp range. A single-phase dental unit with adjustable kVp and mA was employed and the x-ray spectra were experimentally determined at 50, 60 and 70 kVp with 0.5 mA tube current. The pulse height distribution obtained with this detector, however, does not represent the 'true' photon spectra. For this reason, a stripping procedure was implemented to correct the distribution in order to determine the real photon spectra. The x-ray spectra obtained with the CdTe detector were compared with the ones measured with a high-purity germanium detector (EGP200-13-TR by Eurisys Mesures). The reasonable agreement between the results obtained with both detectors for the 50 to 70 keV range show that CdTe detectors can be utilized for dental x-ray spectrometry. (author)

  11. Evaluation of the energy dependence of a zinc oxide nanofilm X-ray detector

    Energy Technology Data Exchange (ETDEWEB)

    Valenca, C.P.V., E-mail: claudia.cpvv@gmail.com [Universidade Federal de Pernambuco (UFPE), Recife (Brazil); Silveira, M.A.L.; Macedo, M.A., E-mail: odecamm@gmail.com [Universidade Federal de Sergipe (UFSE), Sao Cristovao, SE (Brazil); Santos, L.A.P, E-mail: lasantos@scients.com.br [Centro Regional de Ciencias Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2015-07-01

    International organizations of human health and radiation protection have recommended certain care for using of the X-ray as a diagnosis tool to avoid any type of radiological accident or overdose to the patient. This can be done assessing the parameters of the X-ray equipment and there are various types of detectors available for that: ionizing chamber, electronic semiconductor devices, etc. These detectors must be calibrated so that they can be used for any energy range and such a procedure is correlated with what is called the energy dependence of the detector. In accordance with the stated requirements of IEC 61267, the standard radiation quality beams and irradiation conditions (RQRs) are the tools and techniques for calibrating diagnostic X-Ray instruments and detectors. The purpose of this work is to evaluate the behavior of the energy dependence of a detector fabricated from a zinc oxide (ZnO) nanofilm. A Pantak industrial X-ray equipment was used to generate the RQR radiation quality beams and test three ZnO detector samples. A 6430 sub-femto-ammeter, Keithley, was used to bias the ZnO detector and simultaneously perform the output readings. The results showed that the ZnO device has some increase in its sensitivity to the ionizing radiation as the X-ray effective energy decreases unlike other types of semiconductor electronic devices typically used as an X-ray detector. We can conclude that the ZnO device can be used as a diagnostic X-ray detector with an appropriate calibration. (author)

  12. NuSTAR hard x-ray optics design and performance

    DEFF Research Database (Denmark)

    Koglin, J. E.; An, H.; Blaedel, K. L.;

    2009-01-01

    The Nuclear Spectroscopic Telescope Array (NuSTAR) is a NASA satellite mission scheduled for launch in 2011. Using focusing optics with multilayer coating for enhanced reflectivity of hard X-rays (6-79 keV), NuSTAR will provide a combination of clarity, sensitivity and spectral resolution surpass...... design and production process and detail the optics performance....

  13. The Hard X-ray Emission from Scorpius X-1 as Seen by INTEGRAL

    Science.gov (United States)

    Sturner, S. J.; Shrader, C. R.; Weidenspointner, G.

    2008-01-01

    We present the results of our hard X-ray and gamma-ray study of the LMXB Sco X-1 utilizing INTEGRAL data as well as contemporaneous RXTE PCA data. We have concentrated on investigating the hard X-ray spectral properties of Sco X-1 including the nature of the high-energy, nonthermal component of the spectrum and its possible correlations with the location of the source on the X-ray color-color diagram. We find that Sco X-1 has two distinct spectral when the 20-40 keV count rate is greater than 140 counts/second. One state is a hard state which exhibits a significant high-energy, powerlaw tail to the lower energy thermal spectrum. The other state shows no evidence for a powerlaw tail whatsoever. We found suggestive evidence for a correlation of these hard and soft high-energy states with the position of Sco X-1 on the low-energy X-ray color-color diagram.

  14. Evidence for Intermediate Polars as the Origin of the Galactic Center Hard X-ray Emission

    DEFF Research Database (Denmark)

    Hailey, Charles J.; Mori, Kaya; Perez, Kerstin;

    2016-01-01

    Recently, unresolved hard (20-40 keV) X-ray emission has been discovered within the central 10 pc of the Galaxy, possibly indicating a large population of intermediate polars (IPs). Chandra and XMM-Newton measurements in the surrounding ∼50 pc imply a much lighter population of IPs with 〈MWD〉≈0.5...

  15. Overview of segmented glass optics development for the Constellation-X hard X-ray telescope

    DEFF Research Database (Denmark)

    Hailey, C.J; Christensen, Finn Erland; Craig, W.W.;

    2002-01-01

    We report recent work on segmented glass optics for the Constellation-H hard x-ray telescope. This effort seeks to both improve the figure of the free-standing glass substrates, and to refine a newly-developed mounting technology for the substrates. We discuss metrology on recently characterized...

  16. Hard x-ray imaging facility for space shuttle: A scientificq and conceptual engineering study

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, L.E.; Hudson, H.S.; Hurford, G.; Schneible, D.

    1976-11-01

    A shuttle-accommodated instrument for imaging hard X-rays in the study of nonthermal particles and high temperature particles in various solar and cosmic phenomena was defined and its feasibility demonstrated. The imaging system configuration is described as well as the electronics, aspect systems, mechanical and thermal properties and the ground support equipment.

  17. The NuSTAR Hard X-Ray Survey of the Norma Arm Region

    DEFF Research Database (Denmark)

    Fornasini, Francesca M.; Tomsick, John A.; Hong, JaeSub

    2017-01-01

    We present a catalog of hard X-ray sources in a square-degree region surveyed by the Nuclear Spectroscopic Telescope Array (NuSTAR) in the direction of the Norma spiral arm. This survey has a total exposure time of 1.7 Ms, and the typical and maximum exposure depths are 50 ks and 1 Ms, respective...

  18. Electron-based EUV and ultrashort hard-x-ray sources

    Science.gov (United States)

    Egbert, A.; Mader, B.; Tkachenko, B.; Chichkov, B. N.

    2002-11-01

    A brief review of our progress in the realization of femtosecond laser-driven ultrashort hard-x-ray sources is given. New results on the development of electron-based compact EUV sources for "at-wavelength" metrology and next generation lithography are presented. AIP Conference Proceedings.

  19. Development of grazing incidence multilayer mirrors for hard X-ray focusing telescopes

    DEFF Research Database (Denmark)

    Mao, Peter H.; Harrison, Fiona A.; Platonov, Yuriy Y.

    1997-01-01

    We are developing depth-graded, multilayer-coated mirrors for astrophysical hard X-ray focusing telescopes. In this paper, we discuss the primary technical challenges associated with the multilayer coatings, and report on progress to date. We have sputtered constant d-spacing and depth-graded W...

  20. Evidence for Intermediate Polars as the Origin of the Galactic Center Hard X-ray Emission

    DEFF Research Database (Denmark)

    Hailey, Charles J.; Mori, Kaya; Perez, Kerstin

    2016-01-01

    Recently, unresolved hard (20-40 keV) X-ray emission has been discovered within the central 10 pc of the Galaxy, possibly indicating a large population of intermediate polars (IPs). Chandra and XMM-Newton measurements in the surrounding ∼50 pc imply a much lighter population of IPs with 〈MWD〉≈0.5...

  1. The variable hard x-ray emission of NGC 4945 as observed by NUSTAR

    DEFF Research Database (Denmark)

    Puccetti, Simonetta; Comastri, Andrea; Fiore, Fabrizio;

    2014-01-01

    We present a broadband (~0.5-79 keV) spectral and temporal analysis of multiple NuSTAR observations combined with archival Suzaku and Chandra data of NGC 4945, the brightest extragalactic source at 100 keV. We observe hard X-ray (>10 keV) flux and spectral variability, with flux variations of a f...

  2. Multilayer coating facility for the HEFT hard x-ray telescope

    DEFF Research Database (Denmark)

    Cooper-Jensen, Carsten P.; Christensen, Finn Erland; Chen, Hubert

    2001-01-01

    A planar magnetron sputtering facility has been established at the Danish Space Research Institute (DSRI) for the production coating of depth graded multilayers on the thermally slumped glass segments which form the basis for the hard X-ray telescope on the HEFT balloon project. The facility...

  3. Application of an EMCCD camera for calibration of hard X-ray telescopes

    DEFF Research Database (Denmark)

    Vogel, Julia K.; Pivovaro, Michael J.; Craig, William W.

    2012-01-01

    Recent technological innovations make it feasible to construct effcient hard x-ray telescopes for space-based astronomical missions. Focusing optics are capable of improving the sensitivity in the energy range above 10 keV by orders of magnitude compared to previously used instruments. The last d...

  4. Atomic physics with hard X-rays from high brilliance synchrotron light sources

    Energy Technology Data Exchange (ETDEWEB)

    Southworth, S.; Gemmell, D.

    1996-08-01

    A century after the discovery of x rays, the experimental capability for studying atomic structure and dynamics with hard, bright synchrotron radiation is increasing remarkably. Tempting opportunities arise for experiments on many-body effects, aspects of fundamental photon-atom interaction processes, and relativistic and quantum-electrodynamic phenomena. Some of these possibilities are surveyed in general terms.

  5. The Hard X-Ray Emission from Scorpius X-1 Seen by INTEGRAL

    Science.gov (United States)

    Sturner, Steve; Shrader, C. R.

    2008-01-01

    We present the results of our hard X-ray and gamma-ray study of the LMXB Sco X-1 utilizing INTEGRAL data as well as contemporaneous RXTE PCA data. We have investigated the hard X-ray spectral properties of Sco X-1 including the nature of the high-energy, nonthermal component and its possible correlations with the location of the source on the soft X-ray color-color diagram. We find that Sco X-1 follows two distinct spectral tracks when the 20-40 keV count rate is greater than 130 counts/second. One state is a hard state which exhibits a significant high-energy, powerlaw tail to the lower energy thermal spectrum. The other state shows a much less significant high-energy component. We found suggestive evidence for a correlation of these hard and soft high-energy states with the position of Sco X-1 on the low-energy X-ray color-color diagram. We have searched for similar behavior in 2 other Z sources: GX 17+2 and GX 5-1 with negative results.

  6. The First Focused Hard X-ray Images of the Sun with NuSTAR

    CERN Document Server

    Grefenstette, Brian W; Krucker, Säm; Hudson, Hugh; Hannah, Iain G; Smith, David M; Vogel, Julia K; White, Stephen M; Madsen, Kristin K; Marsh, Andrew J; Caspi, Amir; Chen, Bin; Shih, Albert; Kuhar, Matej; Boggs, Steven E; Christensen, Finn E; Craig, William W; Forster, Karl; Hailey, Charles J; Harrison, Fiona A; Miyasaka, Hiromasa; Stern, Daniel; Zhang, William W

    2016-01-01

    We present results from the the first campaign of dedicated solar observations undertaken by the \\textit{Nuclear Spectroscopic Telescope ARray} ({\\em NuSTAR}) hard X-ray telescope. Designed as an astrophysics mission, {\\em NuSTAR} nonetheless has the capability of directly imaging the Sun at hard X-ray energies ($>$3~keV) with an increase in sensitivity of at least two magnitude compared to current non-focusing telescopes. In this paper we describe the scientific areas where \\textit{NuSTAR} will make major improvements on existing solar measurements. We report on the techniques used to observe the Sun with \\textit{NuSTAR}, their limitations and complications, and the procedures developed to optimize solar data quality derived from our experience with the initial solar observations. These first observations are briefly described, including the measurement of the Fe K-shell lines in a decaying X-class flare, hard X-ray emission from high in the solar corona, and full-disk hard X-ray images of the Sun.

  7. Probing bismuth ferrite nanoparticles by hard x-ray photoemission: Anomalous occurrence of metallic bismuth

    Energy Technology Data Exchange (ETDEWEB)

    Chaturvedi, Smita; Rajendra, Ranguwar; Ballav, Nirmalya; Kulkarni, Sulabha, E-mail: s.kulkarni@iiserpune.ac.in [Indian Institute of Science Education and Research, Dr. Homi Bhabha Road, Pune 411008 (India); Sarkar, Indranil [DESY Photon Science, Deutsches Elektronen-Synchrotron, 22607 Hamburg (Germany); Shirolkar, Mandar M. [Hefei National Laboratory for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei, Anhui 230026 (China); Jeng, U-Ser; Yeh, Yi-Qi [National Synchrotron Radiation Research Center, 101, Hsin-Ann Road, Science Park, Hsinchu 3007-6, Taiwan (China)

    2014-09-08

    We have investigated bismuth ferrite nanoparticles (∼75 nm and ∼155 nm) synthesized by a chemical method, using soft X-ray (1253.6 eV) and hard X-ray (3500, 5500, and 7500 eV) photoelectron spectroscopy. This provided an evidence for the variation of chemical state of bismuth in crystalline, phase pure nanoparticles. X-ray photoelectron spectroscopy analysis using Mg Kα (1253.6 eV) source showed that iron and bismuth were present in both Fe{sup 3+} and Bi{sup 3+} valence states as expected for bismuth ferrite. However, hard X-ray photoelectron spectroscopy analysis of the bismuth ferrite nanoparticles using variable photon energies unexpectedly showed the presence of Bi{sup 0} valence state below the surface region, indicating that bismuth ferrite nanoparticles are chemically inhomogeneous in the radial direction. Consistently, small-angle X-ray scattering reveals a core-shell structure for these radial inhomogeneous nanoparticles.

  8. Wire transfer function analysis for castellated dual-energy x-ray detectors.

    Science.gov (United States)

    Chan, Jer Wang; Evans, James Paul Owain; Yong, Yen San; Monteith, Andrew

    2004-12-10

    An investigation into the spatial resolving power of a castellated linear dual-energy x-ray detector array is reported. The detector was developed for use in aviation security screening applications. Experiments employing different gauges of lead wire are used to plot a wire transfer function. A numerical simulation is developed to predict and underpin the empirical results. The suitable processing of the castellated detector signals helps to maintain spatial resolving power while affording a 50% reduction in x-ray sensing elements. This encouraging result has formed the basis for an ongoing investigation into materials discrimination capability of the castellated detector array.

  9. Place of HgI/sub 2/ energy-dispersive x-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Dabrowski, A.J.; Huth, G.C.; Iwanczyk, J.S.; Kusmiss, J.H.; Barton, J.S.; Szymczyk, J.M.; Schnepple, W.F.; Lynn, R.

    1982-01-01

    After a review of solid-state conduction counters, in general, and of the history of mercuric iodide, in particular, the theory of operation of solid-state energy-dispersive HgI/sub 2/ detectors is dicusssed. The main factors which limit energy resolution in solid-state compound detectors are considered, including statistical fluctuations in charge generation, the window effect, trapping, inhomogeneities in the detector material, and electronic noise. Potential applications of room-temperature HgI/sub 2/ x-ray detectors are listed, and general considerations are discussed for x-ray fluorescence analysis with HgI/sub 2/. Directions of current investigations are given. (LEW)

  10. X-ray Hybrid CMOS Detectors : Recent progress in development and characterization

    Science.gov (United States)

    Chattopadhyay, Tanmoy; Falcone, Abraham; Burrows, David N.

    2017-08-01

    PennState high energy astronomy laboratory has been working on the development and characterization of Hybrid CMOS Detectors (HCDs) for last few years in collaboration with Teledyne Imaging Sensors (TIS). HCDs are preferred over X-ray CCDs due to their higher and flexible read out rate, radiation hardness and low power which make them more suitable for next generation large area X-ray telescopic missions. An H2RG detector with 36 micron pixel pitch and 18 micron ROIC, has been selected for a sounding rocket flight in 2018. The H2RG detector provides ~2.5 % energy resolution at 5.9 keV and ~7 e- read noise when coupled to a cryo-SIDECAR. We could also detect a clear Oxygen line (~0.5 keV) from the detector implying a lower energy threshold of ~0.3 keV. Further improvement in the energy resolution and read noise is currently under progress. We have been working on the characterization of small pixel HCDs (12.5 micron pixel; smallest pixel HCDs developed so far) which is important for the development of next generation high resolution X-ray spectroscopic instrument based on HCDs. Event recognition in HCDs is another exciting prospect which have been successfully shown to work with a 64 X 64 pixel prototype SPEEDSTAR-EXD which use comparators at each pixel to read out only those pixels having detectable signal, thereby providing an order of magnitude improvement in the read out rate. Currently, we are working on the development of a large area SPEEDSTAR-EXD array for the development of a full fledged instrument. HCDs due to their fast read out, can also be explored as a large FOV instrument to study GRB afterglows and variability and spectroscopic study of other astrophysical transients. In this context, we are characterizing a Lobster-HCD system at multiple energies and multiple off-axis angles for future rocket or CubeSate experiments. In this presentation, I will briefly present these new developments and experiments with HCDs and the analysis techniques.

  11. Hard X-ray photoelectron and X-ray absorption spectroscopy characterization of oxidized surfaces of iron sulfides

    Science.gov (United States)

    Mikhlin, Yuri; Tomashevich, Yevgeny; Vorobyev, Sergey; Saikova, Svetlana; Romanchenko, Alexander; Félix, Roberto

    2016-11-01

    Hard X-ray photoelectron spectroscopy (HAXPES) using an excitation energy range of 2 keV to 6 keV in combination with Fe K- and S K-edge XANES, measured simultaneously in total electron (TEY) and partial fluorescence yield (PFY) modes, have been applied to study near-surface regions of natural polycrystalline pyrite FeS2 and pyrrhotite Fe1-xS before and after etching treatments in an acidic ferric chloride solution. It was found that the following near-surface regions are formed owing to the preferential release of iron from oxidized metal sulfide lattices: (i) a thin, no more than 1-4 nm in depth, outer layer containing polysulfide species, (ii) a layer exhibiting less pronounced stoichiometry deviations and low, if any, concentrations of polysulfide, the composition and dimensions of which vary for pyrite and pyrrhotite and depend on the chemical treatment, and (iii) an extended almost stoichiometric underlayer yielding modified TEY XANES spectra, probably, due to a higher content of defects. We suggest that the extended layered structure should heavily affect the near-surface electronic properties, and processes involving the surface and interfacial charge transfer.

  12. Evolution of Hard X-Ray Spectra Along the Branches in Cir X-1

    CERN Document Server

    Ding, G Q; Li, T P

    2003-01-01

    Using the data from the PCA and HEXTE on board the RXTE satellite, we investigate the evolution of the 3-200 keV spectra of the peculiar low mass X-ray binary (LMXB) Cir X-1 along the branches on its hardness-intensity diagram (HID) from the vertical horizontal branch (VHB), through the horizontal horizontal branch (HHB) and normal branch (NB), to the flaring branch (FB). We detect a power-law hard component in the spectra. It is found that the derived photon indices ($\\Gamma$) of the power-law hard component are correlated with the position on the HID. The power-law component dominates the X-ray emission of Cir X-1 in the energy band higher than $\\sim 20$ keV. The fluxes of the power-law component are compared with those of the bremsstrahlung component in the spectra. A possible origin of the power-law hard component is discussed.

  13. PheniX: A New Vision for the Hard X-ray Sky

    Science.gov (United States)

    Roques, Jean-Pierre; Jourdain, Elisabeth; Bassani, Loredana; Bazzano, Angela; Belmont, Renaud; Bird, A. J.; Caroli, E.; Chauvin, M.; Clark, D.; Gehrels, N.; hide

    2012-01-01

    We are proposing a mission devoted to high energy X-ray astronomy that is based on a focusing telescope operating in the 1-200 keV energy range but optimized for the hard X-ray range. The main scientific topics concern: Physics of compact objects: The proximity of compact objects provides a unique laboratory to study matter and radiation in extreme conditions of temperature and density in strong gravitational environment. The emission of high energy photons from these objects is far from being understood. The unprecedented sensitivity in the high energy domain will allow a precise determination of the non-thermal processes at work in the vicinity of compact objects. The full 1-200 keV energy coverage will be ideal to disentangle the emission processes produced in the spacetime regions most affected by strong-gravity, as well as the physical links: disk-thermal emission-iron line-comptonisation-reflection-non-thermal emission-jets. Neutron stars-magnetic field-cyclotron lines: Time resolved spectroscopy (and polarimetry) at ultra-high sensitivity of AXP, milliseconds pulsars and magnetars will give new tools to study the role of the synchrotron processes at work in these objects. Cyclotron lines-direct measurement of magnetic filed-equation of state constraints-short bursts-giant flares could all be studied with great details. AGN: The large sensitivity improvement will provide detailed spectral properties of the high energy emission of AGN's. This will give a fresh look to the connection between accretion and jet emission and will provide a new understanding of the physical processes at work. Detection of high-redshift active nuclei in this energy range will allow to introduce an evolutionary aspect to high-energy studies of AGN, probing directly the origin of the Cosmic X-ray Background also in the non-thermal range (> 20 keV). Element formation-Supernovae: The energy resolution achievable for this mission (structure and spectral emission of SNR will advance our

  14. Versatile, reprogrammable area pixel array detector for time-resolved synchrotron x-ray applications

    Energy Technology Data Exchange (ETDEWEB)

    Gruner, Sol [Cornell Univ., Ithaca, NY (United States)

    2010-05-01

    The final technical report for DOE grant DE-SC0004079 is presented. The goal of the grant was to perform research, development and application of novel imaging x-ray detectors so as to effectively utilize the high intensity and brightness of the national synchrotron radiation facilities to enable previously unfeasible time-resolved x-ray research. The report summarizes the development of the resultant imaging x-ray detectors. Two types of detector platforms were developed: The first is a detector platform (called a Mixed-Mode Pixel Array Detector, or MM-PAD) that can image continuously at over a thousand images per second while maintaining high efficiency for wide dynamic range signals ranging from 1 to hundreds of millions of x-rays per pixel per image. Research on an even higher dynamic range variant is also described. The second detector platform (called the Keck Pixel Array Detector) is capable of acquiring a burst of x-ray images at a rate of millions of images per second.

  15. Development and application of cryogenic radiometry with hard X-rays; Entwicklung und Anwendung der Kryoradiometrie mit harter Roentgenstrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Gerlach, Martin

    2008-06-06

    To establish cryogenic radiometry with hard X-ray radiation for photon energies of up to 60 keV, a novel type of cavity absorber had to be developed for the cryogenic radiometer SYRES I, which is deployed by the Physikalisch-Technische Bundesanstalt (PTB) as primary standard detector at the electron storage ring BESSY II. This new type of cavity absorber allows for the complete absorption of hard X-ray radiation in combination with an appropriate sensitivity and an adequate time constant for the measurement of synchrotron radiation at BESSY II. As the process of fabrication of different types of absorbers is very time-consuming, the interaction of hard X-ray radiation with different absorber materials and geometries was studied intensively by using the Monte Carlo simulation code Geant4. The accuracy of the simulations was verified comparing them to scattering experiments performed at a wavelength shifter beamline at BESSY II with a calibrated energy dispersive detector. It was shown that Geant4 describes the photo-effect, including fluorescence as well as Compton- and Rayleigh scattering, with high accuracy. The simulations and experiments resulted in a cavity absorber with a gold base 550 {mu}m in thickness and a cylindrical shell made of copper 90 {mu}m in thickness to reduce losses caused by fluorescence and scattered radiation. Monochromatized synchrotron radiation of high spectral purity was then used to calibrate semiconductor photodiodes, which can be used as compact and inexpensive secondary standard detectors, against a cryogenic radiometer, covering the entire photon energy range of three beamlines from 50 eV to 60 keV with relative uncertainties of less than 0.5 %. Furthermore the spatial homogeneity of the spectral responsivity, the transmittance and the linearity of the photodiodes was investigated. Through a direct comparison of the free-air ionization chamber PK100, a primary detector standard of PTB used in dosimetry, and the cryogenic radiometer

  16. Hard X-ray and microwave sources located around the apex of a solar flare loop

    Science.gov (United States)

    Masuda, S.; Shimojo, M.; Watanabe, K.; Minoshima, T.; Yaji, K.

    2010-12-01

    The apex of a flare loop is one of important regions to understand particle acceleration in solar flares, under the framework of the flare model based on magnetic reconnection. At that portion, nonthermal emissions are observed in hard X-rays and microwave. These two emissions are originated from electrons accelerated/energized in different energy ranges. Hard X-rays (~ 50 - 100 keV ) are emitted by relatively lower-energy (~ 100 keV) accelerated electrons. On the other hand, microwaves (17 GHz) are emitted by relatively higher-energy (~ 1 MeV) electrons. The locations (heights) of these two emitting regions impose considerable constraints on the acceleration/transport/loss processes of electrons in solar flares. To compare hard X-ray and microwave sources, we chose twenty-three events among all events detected by Nobeyama Radio Heliograph (NoRH) during the almost whole period of its operation (1992 - 2008). The criteria are (1) limb event, (2) simultaneous observation with Yohkoh/HXT or RHESSI, (3) enough number of photons in the energy range of 33 - 53 keV, and (4) microwave source large enough to resolve the flare loop into footpoint and looptop sources. However, only seven events among them can be used for this study. The remaining sixteen events are displaced from the list due to no hard X-ray looptop source, too complex structure of multiple loops, and so force. Among the seven events, six events show that the looptop hard X-ray source is located at a higher altitude than the looptop microwave source. This result suggests that lower-energy accelerated electrons (~ 100 keV) are located at a higher altitude than higher-energy (~ 1 MeV) electrons. What makes this height difference? We discuss the cause of it from various kinds of viewpoints, e.g. emission mechanism, trapping effect, transport process, loss process.

  17. Research on pinches driven by Speed-2 generator: Hard X-ray and neutron emission in plasma focus configuration

    Energy Technology Data Exchange (ETDEWEB)

    Soto, L.; Moreno, J.; Silva, P.; Sylvester, G.; Zambra, M.; Pavez, C. [Comision Chilena de Energia Nuclear, Santiago (Chile); Pavez, C. [Universidad de Concepcion (Chile); Raspa, V. [Buenos Aires Univ., PLADEMA, CONICET and INFIP (Argentina); Castillo, F. [Insitituto de Ciencias Nucleares, UNAM (Mexico); Kies, W. [Heinrich-Heine-Univ., Dusseldorf (Germany)

    2004-07-01

    Speed-2 is a generator based on Marx technology and was designed in the University of Dusseldorf. Speed-2 consists on 40 +/- Marx modules connected in parallel (4.1 {mu}F equivalent Marx generator capacity, 300 kV, 4 MA in short circuit, 187 kJ, 400 ns rise time, dI/dt {approx} 10{sup 13} A/s). Currently Speed-2 is operating at CCHEN (Chilean nuclear energy commission), being the most powerful and energetic device for dense transient plasma in the Southern Hemisphere. Most of the previous works developed in Speed-2 at Dusseldorf were done in a plasma focus configuration for soft X-ray emission and the neutron emission from Speed-2 was not completely studied. The research program at CCHEN considers experiments in different pinch configurations (plasma focus, gas puffed plasma focus, gas embedded Z-pinch, wire arrays) at current of hundred of kilo- to mega-amperes, using the Speed-2 generator. The Chilean operation has begun implementing and developing diagnostics in a conventional plasma focus configuration operating in deuterium in order to characterize the neutron emission and the hard X-ray production. Silver activation counters, plastics CR39 and scintillator-photomultiplier detectors are used to characterize the neutron emission. Images of metallic plates with different thickness are obtained on commercial radiographic film, Agfa Curix ST-G2, in order to characterize an effective energy of the hard X-ray outside of the discharge. (authors)

  18. Comparison of three types of XPAD3.2/CdTe single chip hybrids for hard X-ray applications in material science and biomedical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Buton, C., E-mail: clement.buton@synchrotron-soleil.fr [Synchrotron SOLEIL, L´Orme des Merisiers, Saint-Aubin — BP 48 91192, Gif-sur-Yvette Cedex (France); Dawiec, A. [Synchrotron SOLEIL, L´Orme des Merisiers, Saint-Aubin — BP 48 91192, Gif-sur-Yvette Cedex (France); Graber-Bolis, J.; Arnaud, K. [CPPM, Aix-Marseille Université, CNRS/IN2P3, Marseille (France); Bérar, J.F.; Blanc, N.; Boudet, N. [Université Grenoble Alpes, Institut NÉEL, F-38042 Grenoble (France); CNRS, Institut NÉEL, F-38042 Grenoble (France); Clémens, J.C.; Debarbieux, F. [CPPM, Aix-Marseille Université, CNRS/IN2P3, Marseille (France); Delpierre, P.; Dinkespiler, B. [imXPAD SAS — Espace Mistral, Athélia IV, 297 avenue du Mistral, 13600 La Ciotat (France); Gastaldi, T. [CPPM, Aix-Marseille Université, CNRS/IN2P3, Marseille (France); Hustache, S. [Synchrotron SOLEIL, L´Orme des Merisiers, Saint-Aubin — BP 48 91192, Gif-sur-Yvette Cedex (France); Morel, C.; Pangaud, P. [CPPM, Aix-Marseille Université, CNRS/IN2P3, Marseille (France); Perez-Ponce, H. [imXPAD SAS — Espace Mistral, Athélia IV, 297 avenue du Mistral, 13600 La Ciotat (France); Vigeolas, E. [CPPM, Aix-Marseille Université, CNRS/IN2P3, Marseille (France)

    2014-09-11

    The CHIPSPECT consortium aims at building a large multi-modules CdTe based photon counting detector for hard X-ray applications. For this purpose, we tested nine XPAD3.2 single chip hybrids in various configurations (i.e. Ohmic vs. Schottky contacts or electrons vs. holes collection mode) in order to select the most performing and best suited configuration for our experimental requirements. Measurements have been done using both X-ray synchrotron beams and {sup 241}Am source. Preliminary results on the image quality, calibration, stability, homogeneity and linearity of the different types of detectors are presented.

  19. Integration of flat panel X-ray detector for high resolution diagnostic medical imaging

    Science.gov (United States)

    Kim, Min-Woo; Yun, Min-Seok; Kim, Yoon-Suk; Oh, Kyung-Min; Shin, Jung-Wook; Nam, Kyung-Tae; Nam, Sang-Hee

    2011-05-01

    In these days, flat panel X-ray image detectors have shown their potential for replacing traditional screen-film systems. To detect the X-ray photon energy, there are two main methods known as a direct method and an indirect method. The X-rays are converted immediately into electrical signal with the direct method. The indirect method has two conversion steps: the scintillator absorbs the X-rays and converts them to visible light. And then the visible light is converted to electrical signal (e.g. by photodiodes). In this work, the flat panel digital X-ray image detector based on direct method with a high atomic number material was designed and evaluated. The high atomic number material for X-ray conversion is deposited by a rubbing method with about 300 μm. The rubbing method is similar to the screen printing method. It consists of two elements: the screen and the squeegee. The method uses a proper stiff bar stretched tightly over a frame made of wood or metal. Proper tension is essential for proper laminated structure. The detector prototype has 139 μm pixel pitch, total 1280×1536 pixels and 86% fill factor. Twelve readout ICs are installed on digital X-ray detector and simultaneously operated to reach short readout time. The electronics integrated: the preamplifier to amplify generated signal, the Analog to Digital converter and the source of bias voltage (1 V/μm). The system board and interface use an NI-camera program. Finally, we achieved images from this flat panel X-ray image detector.

  20. Towards multi-order hard X-ray imaging with multilayer zone plates.

    Science.gov (United States)

    Osterhoff, Markus; Eberl, Christian; Döring, Florian; Wilke, Robin N; Wallentin, Jesper; Krebs, Hans-Ulrich; Sprung, Michael; Salditt, Tim

    2015-02-01

    This article describes holographic imaging experiments using a hard X-ray multilayer zone plate (MZP) with an outermost zone width of 10 nm at a photon energy of 18 keV. An order-sorting aperture (OSA) is omitted and emulated during data analysis by a 'software OSA'. Scanning transmission X-ray microscopy usually carried out in the focal plane is generalized to the holographic regime. The MZP focus is characterized by a three-plane phase-retrieval algorithm to an FWHM of 10 nm.

  1. Origin of Thermal and Non-Thermal Hard X-ray Emission from the Galactic Center

    CERN Document Server

    Dogiel, Vladimir; Yuasa, Takayuki; Prokhorov, Dmitrii; Cheng, Kwong-Sang; Bamba, Aya; Inoue, Hajime; Ko, Chung-Ming; Kokubun, Motohide; Maeda, Yoshitomo; Mitsuda, Kazuhisa; Nakazawa, Kazuhiro; Yamasaki, Noriko Y

    2009-01-01

    We analyse new results of Chandra and Suzaku which found a flux of hard X-ray emission from the compact region around Sgr A$^\\ast$ (r ~ 100 pc). We suppose that this emission is generated by accretion processes onto the central supermassive blackhole when an unbounded part of captured stars obtains an additional momentum. As a result a flux of subrelativistic protons is generated near the Galactic center which heats the background plasma up to temperatures about 6-10 keV and produces by inverse bremsstrahlung a flux of non-thermal X-ray emission in the energy range above 10 keV.

  2. Measuring optical constants of multilayer materials for current and future hard X-ray space telescopes

    Science.gov (United States)

    Brejnholt, Nicolai

    With the launch of the NuSTAR space telescope in 2012, a new era in X-ray astronomy began. NuSTAR provides astronomers unprecedented sensitivity in the hard X-ray band, operating from 6-79 keV through the use of multilayers. At lower energies, NuSTAR has an effective area comparable to previous missions, such as the XMM-Newton and Chandra. The overlap allows soft X-ray observations to be combined with hard X-ray ones, providing new constraints on theoretical models and allowing accurate determination of the properties of thermal and non-thermal processes. To successfully predict the performance of a hard X-ray multilayer telescope, precise knowledge of the optical properties of the constituent materials of the multilayers is required. Tungsten and platinum are the two high-density, high-Z materials in the NuSTAR multilayer systems, but early observations with NuSTAR showed that essential atomic parameters , i.e. the optical constants, of these materials are not correct. Specifically, there are significant residuals in spectral fits near the L absorption edges of both materials from 10-14 keV. This situation is not a surprise, as the optical constants for these materials are derived from tabulated photon-interaction cross sections, which does not properly capture the physics of the X-ray absorption fine structure (XAFS). As a result, the NuSTAR team is using an empirical correction to predict performance. The correction does not completely remove spectral features in the 10-14 keV region and is only good for weak sources. We propose to accurately measure the optical constants for tungsten and platinum in the hard X-ray region from 6-28.5 keV, replacing the empirical correction and providing a significant improvement to NuSTAR's response model. The improvement will be achieved by two independent and complementary routes to increase accuracy. One method relies on transmission measurements while the other utilizes reflection measurements. The proposing team leverages

  3. Balloon-borne hard X-ray polarimetry with PoGOLite

    CERN Document Server

    ,

    2012-01-01

    PoGOLite is a hard X-ray polarimeter operating in the 25-100 keV energy band. The instrument design is optimised for the observation of compact astrophysical sources. Observations are conducted from a stabilised stratospheric balloon platform at an altitude of approximately 40 km. The primary targets for first balloon flights of a reduced effective area instrument are the Crab and Cygnus-X1. The polarisation of incoming photons is determined using coincident Compton scattering and photo-absorption events reconstructed in an array of plastic scintillator detector cells surrounded by a bismuth germanate oxide (BGO) side anticoincidence shield and a polyethylene neutron shield. A custom attitude control system keeps the polarimeter field-of-view aligned to targets of interest, compensating for sidereal motion and perturbations such as torsional forces in the balloon rigging. An overview of the PoGOLite project is presented and the outcome of the ill-fated maiden balloon flight is discussed.

  4. Hard X-ray observations of GRS/KS 1730-312 with GRANAT/SIGMA.

    Science.gov (United States)

    Trudolyubov, S.; Gilfanov, M.; Churazov, E.; Sunyaev, R.; Borozdin, K.; Alexandrovich, N.; Khavenson, N.; Novikov, B.; Vargas, M.; Goldwurm, A.; Paul, J.; Denis, M.; Mandrou, P.; Roques, J.-P.; Jourdain, E.; Borrel, V.

    1996-02-01

    The results of transient X-ray source KS/GRS 1730-312 observations with GRANAT/SIGMA are reported. The source was discovered on September 23, 1994 and at the maximum of the light curve was the brightest one in the Galactic Center region in the 35-200 keV energy domain. Within ≡5 d the hard X-ray flux from GRS/KS 1730-312 declined below the SIGMA sensitivity limit. The average 35-200 keV spectrum can be approximated by the power law spectrum with photon index ≡2.5 or by bremsstrahlung model with temperature ≡70 keV. Some steepening of the 35-200 keV spectrum with time was marginally detected. According to the TTM (Mir-KVANT) data the decline of hard X-ray flux was accompanied by notable increase of the flux in the standard X-ray band (2-10 keV). During 5 d the 2-10 keV band contribution to the 2-300 keV luminosity increased from ≡20-25% to ≡80-90%. Combined TTM and SIGMA data indicate that the broad band (2-300 keV) spectrum evolution may be described in terms of appearance and fast increase of the soft spectral component accompanied with decrease and possible steepening of the hard component.

  5. Hard X-ray variability of V404 Cyg during the 2015 outburst

    CERN Document Server

    Sanchez-Fernandez, C; Motta, S E; Kuulkers, E

    2016-01-01

    Aims. Hard X-ray spectra of black hole binaries (BHB) are produced by Comptonization of soft seed photons by hot electrons near the black hole. The slope of the resulting energy spectra is governed by two main parameters: the electron temperature and the optical depth of the emitting plasma. Given the extreme brightness of V404 Cyg during the 2015 outburst, we aim to constraint the source spectral properties using an unprecedented time resolution in hard X-rays, and to monitor their evolution over the whole outburst. Methods. We have extracted and analyzed 602 X-ray spectra of V404 Cyg obtained during the 2015 June outburst by the IBIS/ISGRI instrument onboard INTEGRAL. We have performed time-resolved spectral analysis, using a time resolution ranging between 64 and 176000 seconds. The spectra were fitted in the 20-200 keV energy range. Results. We find that while the V404 Cyg light curve and soft X-ray spectra are remarkably different from other BHBs light curves, the spectral evolution of V404 Cyg in hard X...

  6. Observations of a hard X-ray component in the spectrum of Nova Ophiuchi

    Science.gov (United States)

    Wilson, C. K.; Rothschild, R. E.

    1983-01-01

    The spectrum and time variation of Nova Ophiuchi (H1705-25) in the 10-200 keV range as measured by the UCSD/MIT instruments aboard HEAO 1 during the period 1977 August 25 to September 28 are reported. The composite curve is best fitted by a kT = 2 keV thin thermal bremsstrahlung model below 10 keV and a separate hard X-ray component fitted equally well by a power-law component with photon index 2.19 + or - 0.06 or a kT = 32.1 + or - 2.4 keV thermal bremsstrahlung model. This is the first observation of a hard tail in the spectrum of a transient X-ray source with sufficient statistical significance to allow a detailed study of its spectral and temporal variability. It is found that the intensity variations of the high-energy X-rays are consistent with the variability at lower energies (3-6 keV), but no hard X-ray spectral index variability is found on time scales from 2 days to 2 weeks. The results can be interpreted as due to accretion onto a neutron star (or possibly onto a black hole) that may also be surrounded by an extended corona.

  7. POLAR - novel hard X-ray polarimeter for Gamma Ray Bursts

    Science.gov (United States)

    Hajdas, Wojtek

    Our present knowledge of the Gamma Ray Bursts GRBs - the most powerful explosions in the universe after the Big Bang - links them with a birth of the black holes and localize at cosmological distances. There is also a strong evidence relating some of them with Supernovae and thus with gravitational waves. Despite of such significant role of GRBs only little is known about their mechanisms and progenitors. Existing theories still have troubles describing bursts prompt emissions while predictions of the photon polarization show large divergences. On the observational side there are just few isolated measurements of the hard X-ray polarization affected by large experimental uncertainties. Nevertheless, it became clear that determining the GRB polarization could be an ultimate step for understanding their genuine nature. To participate in this task we propose POLAR - novel instrument for hard X-ray and low energy gamma ray polarimetry. The instrument goal is to perform highly precise polarization studies from a very large number of GRBs. Measurements of the linear polarization in the GRB prompt emission at photon energies from 5 keV to 500 keV will be carried out using continuous observations of the sky. Our calculations showed that for several bursts per year the experimental precision will reach a 1 sigma level of 3 per cent. For the strongest events it will be possible to study polarization as a function of energy achieving much more detailed view of the emitting system structure. POLAR uses a uniform array of 1600 weakly shielded plastic detectors coupled with the new multi-anode photo-multipliers. The polarization measurement is based on Compton scattering and relies on detection of fast coincidences between plastic scintillator bars. The total mass (28 kg) and power requirements (30 W) are very moderate. POLAR has relatively small dimensions and it was designed to be not only non-intrusive but also highly adaptable. The qualification model is currently under

  8. Projection x-ray imaging with photon energy weighting: experimental evaluation with a prototype detector.

    Science.gov (United States)

    Shikhaliev, Polad M

    2009-08-21

    The signal-to-noise ratio (SNR) in x-ray imaging can be increased using a photon counting detector which could allow for rejecting electronics noise and for weighting x-ray photons according to their energies. This approach, however, was not feasible for a long time because photon counting x-ray detectors with very high count rates, good energy resolution and a large number of small pixels were required. These problems have been addressed with the advent of new detector materials, fast readout electronics and powerful computers. In this work, we report on the experimental evaluation of projection x-ray imaging with a photon counting cadmium-zinc-telluride (CZT) detector with energy resolving capabilities. The detector included two rows of pixels with 128 pixels per row with 0.9 x 0.9 mm(2) pixel size, and a 2 Mcount pixel(-1) s(-1) count rate. The x-ray tube operated at 120 kVp tube voltage with 2 mm Al-equivalent inherent filtration. The x-ray spectrum was split into five regions, and five independent x-ray images were acquired at a time. These five quasi-monochromatic x-ray images were used for x-ray energy weighting and material decomposition. A tissue-equivalent phantom was used including contrast elements simulating adipose, calcifications, iodine and air. X-ray energy weighting improved the SNR of calcifications and iodine by a factor of 1.32 and 1.36, respectively, as compared to charge integrating. Material decomposition was performed by dual energy subtraction. The low- and high-energy images were generated in the energy ranges of 25-60 keV and 60-120 keV, respectively, by combining five monochromatic image data into two. X-ray energy weighting was applied to low- and high-energy images prior to subtraction, and this improved the SNR of calcifications and iodine in dual energy subtracted images by a factor of 1.34 and 1.25, respectively, as compared to charge integrating. The detector energy resolution, spatial resolution, linearity, count rate, noise and

  9. Improved hard x-ray (50-80 keV) imaging of hohlraum implosion experiments at the National Ignition Facility

    Science.gov (United States)

    Bachmann, B.; Chow, R.; Palmer, N. E.; Hoover, M.; Huffman, E.; Lee, J. J.; Romano, E.; Kumar, C.; Hulbert, R. D.; Albert, F.; Dewald, E. L.; Divol, L.; Hohenberger, M.; Landen, O. L.; Warrick, A.; Döppner, T.

    2016-09-01

    We recently designed, built and commissioned a new pinhole / filter assembly for the equatorial hard x-ray imager (eHXI) at the National Ignition Facility (NIF). In this paper we describe the design and metrology of the new diagnostic as well as the spectral and spatial response of the hard x-ray detector. The new eHXI assembly has improved the photon collection efficiency along with spectral and spatial resolution by making use of 1D imaging channels and various hard x-ray filters. In addition we added a Ross pair filter set for Au K-alpha emission (67-69 keV). The new eHXI design will improve our understanding of the sourcing of hot electrons, generated in laser-plasma-instabilities, along the vertical hohlraum axis. This information is an important input for simulating and eventually limiting the DT fuel preheat in ICF implosions.

  10. Directly-deposited blocking filters for high-performance silicon x-ray detectors

    Science.gov (United States)

    Bautz, M.; Kissel, S.; Masterson, R.; Ryu, K.; Suntharalingam, V.

    2016-07-01

    Silicon X-ray detectors often require blocking filters to mitigate noise and out-of-band signal from UV and visible backgrounds. Such filters must be thin to minimize X-ray absorption, so direct deposition of filter material on the detector entrance surface is an attractive approach to fabrication of robust filters. On the other hand, the soft (E X-ray spectral resolution of the detector is sensitive to the charge collection efficiency in the immediate vicinity of its entrance surface, so it is important that any filter layer is deposited without disturbing the electric field distribution there. We have successfully deposited aluminum blocking filters, ranging in thickness from 70 to 220nm, on back-illuminated CCD X-ray detectors passivated by means of molecular beam epitaxy. Here we report measurements showing that directly deposited filters have little or no effect on soft X-ray spectral resolution. We also find that in applications requiring very large optical density (> OD 6) care must be taken to prevent light from entering the sides and mounting surfaces of the detector. Our methods have been used to deposit filters on the detectors of the REXIS instrument scheduled to fly on OSIRIS-ReX later this year.

  11. Compensational scintillation detector with a flat energy response for flash X-ray measurements

    Science.gov (United States)

    Chen, Liang; Ouyang, Xiaoping; Liu, Bin; Liu, Jinliang; Quan, Lin; Zhang, Zhongbing

    2013-01-01

    To measure the intensity of flash X-ray sources directly, a novel scintillation detector with a fast time response and flat energy response is developed by combining film scintillators of doped ZnO crystal and fast organic scintillator together. Through compensation design, the dual-scintillator detector (DSD) achieved a flat energy response to X-rays from tens of keV to several MeV, and sub-nanosecond time response by coupling to ultrafast photo-electronic devices. A prototype detector was fabricated according to the theoretical design; it employed ZnO:In and EJ228 with thicknesses of 0.3 mm and 0.1 mm, respectively. The energy response of this detector was tested on monoenergetic X-ray and γ-ray sources. The detector performs very well with a sensitivity fluctuation below 5% for 8 discrete energy points within the 40-250 keV energy region and for other energies of 662 keV and 1.25 MeV as well, showing good accordance with the theoretical design. Additionally, the detector works properly for the application to the flash X-ray radiation field absolute intensity measurement. This DSD may be very useful for the diagnosis of time-resolved dynamic physical processes of flash X-ray sources without knowing the exact energy spectrum.

  12. HARD X-RAY AND MICROWAVE EMISSIONS FROM SOLAR FLARES WITH HARD SPECTRAL INDICES

    Energy Technology Data Exchange (ETDEWEB)

    Kawate, T. [Kwasan and Hida Observatory, Kitashirakawa-oiwakecho, Sakyo, Kyoto 606-8502 (Japan); Nishizuka, N. [Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency, 3-1-1 Yoshinodai, Chuo-ku, Sagamihara, Kanagawa 229-8510 (Japan); Oi, A. [College of Science, Ibaraki University, Mito, Ibaraki 310-8512 (Japan); Ohyama, M. [Faculty of Education, Shiga University, 2-5-1 Hiratsu, Otsu, Shiga 1-1, Baba Hikone city, Siga 522-8522 (Japan); Nakajima, H., E-mail: kawate@kusastro.kyoto-u.ac.jp [Nobeyama Solar Radio Observatory, NAOJ, Nobeyama, Minamisaku, Nagano 384-1305 (Japan)

    2012-03-10

    We analyze 10 flare events that radiate intense hard X-ray (HXR) emission with significant photons over 300 keV to verify that the electrons that have a common origin of acceleration mechanism and energy power-law distribution with solar flares emit HXRs and microwaves. Most of these events have the following characteristics. HXRs emanate from the footpoints of flare loops, while microwaves emanate from the tops of flare loops. The time profiles of the microwave emission show delays of peak with respect to those of the corresponding HXR emission. The spectral indices of microwave emissions show gradual hardening in all events, while the spectral indices of the corresponding HXR emissions are roughly constant in most of the events, though rather rapid hardening is simultaneously observed in some for both indices during the onset time and the peak time. These characteristics suggest that the microwave emission emanates from the trapped electrons. Then, taking into account the role of the trapping of electrons for the microwave emission, we compare the observed microwave spectra with the model spectra calculated by a gyrosynchrotron code. As a result, we successfully reproduce the eight microwave spectra. From this result, we conclude that the electrons that have a common acceleration and a common energy distribution with solar flares emit both HXR and microwave emissions in the eight events, though microwave emission is contributed to by electrons with much higher energy than HXR emission.

  13. Comparison of natural and synthetic diamond X-ray detectors.

    Science.gov (United States)

    Lansley, S P; Betzel, G T; Metcalfe, P; Reinisch, L; Meyer, J

    2010-12-01

    Diamond detectors are particularly well suited for dosimetry applications in radiotherapy for reasons including near-tissue equivalence and high-spatial resolution resulting from small sensitive volumes. However, these detectors have not become commonplace due to high cost and poor availability arising from the need for high-quality diamond. We have fabricated relatively cheap detectors from commercially-available synthetic diamond fabricated using chemical vapour deposition. Here, we present a comparison of one of these detectors with the only commercially-available diamond-based detector (which uses a natural diamond crystal). Parameters such as the energy dependence and linearity of charge with dose were investigated at orthovoltage energies (50-250 kV), and dose-rate dependence of charge at linear accelerator energy (6 MV). The energy dependence of a synthetic diamond detector was similar to that of the natural diamond detector, albeit with slightly less variation across the energy range. Both detectors displayed a linear response with dose (at 100 kV) over the limited dose range used. The sensitivity of the synthetic diamond detector was 302 nC/Gy, compared to 294 nC/Gy measured for the natural diamond detector; however, this was obtained with a bias of 246.50 V compared to a bias of 61.75 V used for the natural diamond detector. The natural diamond detector exhibited a greater dependency on dose-rate than the synthetic diamond detector. Overall, the synthetic diamond detector performed well in comparison to the natural diamond detector.

  14. Methods for characterizing x-ray detectors for use at the National Ignition Facility.

    Science.gov (United States)

    Khan, S F; Benedetti, L R; Hargrove, D R; Glenn, S M; Simanovskaia, N; Holder, J P; Barrios, M A; Hahn, D; Nagel, S R; Bell, P M; Bradley, D K

    2012-10-01

    Gated and streaked x-ray detectors generally require corrections in order to counteract instrumental effects in the data. The method of correcting for gain variations in gated cameras fielded at National Ignition Facility (NIF) is described. Four techniques for characterizing the gated x-ray detectors are described. The current principal method of characterizing x-ray instruments is the production of controlled x-ray emission by laser-generated plasmas as a dedicated shot at the NIF. A recently commissioned pulsed x-ray source has the potential to replace the other characterization systems. This x-ray source features a pulsed power source consisting of a Marx generator, capacitor bank that is charged in series and discharged in parallel, producing up to 300 kV. The pulsed x-ray source initially suffered from a large jitter (∼60 ns), but the recent addition of a pulsed laser to trigger the spark gap has reduced the jitter to ∼5 ns. Initial results show that this tool is a promising alternative to the other flat fielding techniques.

  15. A cooled avalanche photodiode detector for X-ray magnetic diffraction experiments

    CERN Document Server

    Kishimoto, S; Ito, M

    2001-01-01

    A cooled avalanche photodiode (APD) detector was developed for X-ray magnetic diffraction experiments. A stack of four silicon APDs was cooled down to 243 K by a thermoelectric cooler. The energy widths of 0.89 and 1.55 keV (FWHM) were obtained for 8.05 keV X-rays at 1x10 sup 6 s sup - sup 1 and for 16.53 keV X-rays at 2x10 sup 6 s sup - sup 1 , respectively. Test measurements of X-ray magnetic diffraction were executed using a terbium single crystal and white synchrotron radiation. A peak width of (1 0 3) reflection (5.4 keV) was roughly three times wider than that with a high-purity germanium detector.

  16. X-ray position detector and implementation in a mirror pointing servo system

    Science.gov (United States)

    Rabedeau, Thomas A.; Van Campen, Douglas G.; Stefan, Peter M.

    2016-04-05

    An X-ray beam position and stability detector is provided having a first metal blade collinear with a second metal blade, where an edge of the first metal blade is opposite an edge of the second metal blade, where the first metal blade edge and the second metal blade edge are disposed along a centerline with respect to each other, where the metal blades are capable of photoelectron emission when exposed to an x-ray beam, a metal coating on the metal blades that is capable of enhancing the photoelectron emission, or suppressing energy-resonant contaminants, or enhancing the photoelectron emission and suppressing energy-resonant contaminants, a background shielding element having an electrode capable of suppressing photoelectron emission from spurious x-rays not contained in an x-ray beam of interest, and a photoelectron emission detector having an amplifier capable of detecting the photoelectron emission as a current signal.

  17. Note: application of a pixel-array area detector to simultaneous single crystal X-ray diffraction and X-ray absorption spectroscopy measurements.

    Science.gov (United States)

    Sun, Cheng-Jun; Zhang, Bangmin; Brewe, Dale L; Chen, Jing-Sheng; Chow, G M; Venkatesan, T; Heald, Steve M

    2014-04-01

    X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS) are two main x-ray techniques in synchrotron radiation facilities. In this Note, we present an experimental setup capable of performing simultaneous XRD and XAS measurements by the application of a pixel-array area detector. For XRD, the momentum transfer in specular diffraction was measured by scanning the X-ray energy with fixed incoming and outgoing x-ray angles. By selecting a small fixed region of the detector to collect the XRD signal, the rest of the area was available for collecting the x-ray fluorescence for XAS measurements. The simultaneous measurement of XRD and X-ray absorption near edge structure for Pr0.67Sr0.33MnO3 film was demonstrated as a proof of principle for future time-resolved pump-probe measurements. A static sample makes it easy to maintain an accurate overlap of the X-ray spot and laser pump beam.

  18. The column density distribution of hard X-ray radio galaxies

    Science.gov (United States)

    Panessa, F.; Bassani, L.; Landi, R.; Bazzano, A.; Dallacasa, D.; La Franca, F.; Malizia, A.; Venturi, T.; Ubertini, P.

    2016-09-01

    In order to investigate the role of absorption in active galactic nuclei (AGN) with jets, we have studied the column density distribution of a hard X-ray selected sample of radio galaxies, derived from the INTEGRAL/Imager on Board the Integral Satellite (IBIS) and Swift/The Burst Alert Telescope (BAT) AGN catalogues (˜7-10 per cent of the total AGN population). The 64 radio galaxies have a typical FR II radio morphology and are characterized by high 20-100 keV luminosities (from 1042 to 1046 erg s-1) and high Eddington ratios (log LBol/LEdd typically larger than ˜0.01). The observed fraction of absorbed AGN (NH > 1022 cm-2) is around 40 per cent among the total sample, and ˜75 per cent among type 2 AGN. The majority of obscured AGN are narrow-line objects, while unobscured AGN are broad-line objects, obeying to the zeroth-order predictions of unified models. A significant anti-correlation between the radio core dominance parameter and the X-ray column density is found. The observed fraction of Compton thick AGN is ˜2-3 per cent, in comparison with the 5-7 per cent found in radio-quiet hard X-ray selected AGN. We have estimated the absorption and Compton thick fractions in a hard X-ray sample containing both radio galaxies and non-radio galaxies and therefore affected by the same selection biases. No statistical significant difference was found in the absorption properties of radio galaxies and non-radio galaxies sample. In particular, the Compton thick objects are likely missing in both samples and the fraction of obscured radio galaxies appears to decrease with luminosity as observed in hard X-ray non-radio galaxies.

  19. Resonant Compton Upscattering Models of Magnetar Hard X-ray Emission and Polarization

    Science.gov (United States)

    Baring, Matthew G.; Wadiasingh, Zorawar; Gonthier, Peter L.; Kust Harding, Alice

    2017-08-01

    Non-thermal quiescent X-ray emission extending between 10 keV and around 150 keV has been seen in about 10 magnetars by RXTE, INTEGRAL, Suzaku and Fermi-GBM. For inner magnetospheric models of such hard X-ray signals, resonant Compton upscattering is anticipated to be the most efficient process for generating the continuum radiation. This is because the scattering becomes resonant at the cyclotron frequency, and the effective cross section exceeds the classical Thomson value by over two orders of magnitude. We present angle-dependent hard X-ray upscattering model spectra for uncooled monoenergetic relativistic electrons injected in inner regions of pulsar magnetospheres. These spectra are integrated over closed field lines and obtained for different observing perspectives. The spectral cut-off energies are critically dependent on the observer viewing angles and electron Lorentz factor. We find that electrons with energies less than around 15 MeV will emit most of their radiation below 250 keV, consistent with the observed turnovers in magnetar hard X-ray tails. Moreover, electrons of higher energy still emit most of the radiation below around 1 MeV, except for quasi-equatorial emission locales for select pulses phases. In such cases, attenuation mechanisms such as pair creation will be prolific, thereby making it difficult to observe signals extending into the Fermi-LAT band. Our spectral computations use new state-of-the-art, spin-dependent formalism for the QED Compton scattering cross section in strong magnetic fields. The emission exhibits strong polarization above around 30 keV that is anticipated to be dependent on pulse phase, thereby defining science agendas for future hard X-ray polarimeters.

  20. A Hard X-Ray Power-law Spectral Cutoff in Centaurus X-4

    Science.gov (United States)

    Chakrabarty, Deepto; Tomsick, John A.; Grefenstette, Brian W.; Psaltis, Dimitrios; Bachetti, Matteo; Barret, Didier; Boggs, Steven E.; Christensen, Finn E.; Craig, William W.; Fürst, Felix; Hailey, Charles J.; Harrison, Fiona A.; Kaspi, Victoria M.; Miller, Jon M.; Nowak, Michael A.; Rana, Vikram; Stern, Daniel; Wik, Daniel R.; Wilms, Jörn; Zhang, William W.

    2014-12-01

    The low-mass X-ray binary (LMXB) Cen X-4 is the brightest and closest (law tail of unknown origin. We report here on a simultaneous observation of Cen X-4 with NuSTAR (3-79 keV) and XMM-Newton (0.3-10 keV) in 2013 January, providing the first sensitive hard X-ray spectrum of a quiescent neutron star transient. The 0.3-79 keV luminosity was 1.1× 1033 D^2_kpc erg s-1, with sime60% in the thermal component. We clearly detect a cutoff of the hard spectral tail above 10 keV, the first time such a feature has been detected in this source class. We show that thermal Comptonization and synchrotron shock origins for the hard X-ray emission are ruled out on physical grounds. However, the hard X-ray spectrum is well fit by a thermal bremsstrahlung model with kTe = 18 keV, which can be understood as arising either in a hot layer above the neutron star atmosphere or in a radiatively inefficient accretion flow. The power-law cutoff energy may be set by the degree of Compton cooling of the bremsstrahlung electrons by thermal seed photons from the neutron star surface. Lower thermal luminosities should lead to higher (possibly undetectable) cutoff energies. We compare Cen X-4's behavior with PSR J1023+0038, IGR J18245-2452, and XSS J12270-4859, which have shown transitions between LMXB and radio pulsar modes at a similar X-ray luminosity.

  1. On-orbit calibration of soft X-ray detector on Chang'E-2 satellite

    Science.gov (United States)

    Xiao, Hong; Peng, Wen-Xi; Wang, Huan-Yu; Cui, Xing-Zhu; Guo, Dong-Ya

    2015-10-01

    The X-ray spectrometer is one of the satellite payloads on the Chang'E-2 satellite. The soft X-ray detector is one of the devices on the X-ray spectrometer, designed to detect the major rock-forming elements within the 0.5-10 keV range on the lunar surface. In this paper, energy linearity and energy resolution calibration is done using a weak 55Fe source. Temperature and time effects are found not to give a large error. The total uncertainty of calibration is estimated to be within 5% after correction. Supported by National Science Foundation of Ministry of Education

  2. On-orbit calibration of soft X-ray detector on Chang'E-2 satellite

    CERN Document Server

    Xiao, Hong; Wang, Huanyu; Cui, Xingzhu; Guo, Dongya

    2015-01-01

    X-ray spectrometer is one of the satellite payloads on Chang'E-2 satellite. The soft X-ray detector is one of the device on X-ray spectrometer which is designed to detect the major rock-forming elements within 0.5-10keV range on lunar surface. In this paper, energy linearity and energy resolution calibration is done using a weak Fe55 source, while temperature and time effect is considered not take big error. The total uncertainty is estimated to be within 5% after correction.

  3. The Swift BAT Hard X-ray Survey - A New Window on the Local AGN Universe

    Science.gov (United States)

    Mushotzky, Richard

    2009-01-01

    The Swift Burst and Transient telescope (BAT) has surveyed the entire sky for the last 3.5 years obtaining the first sensitive all sky survey of the 14-195 keV sky. At high galactic latitudes the vast majority of the detected sources are AGN. Since hard x-rays penetrate all but Compton thick obscuring material (Column densities of 1.6E24 atms/cm2) this survey is unbiased with respect to obscuration, host galaxy type, optical , radio or IR properties. We will present results on the broad band x-ray properties, the nature of the host galaxies, the luminosity function and will discuss a few of the optical, IR and x-ray results in detail.

  4. An exploratory study of the hard X-ray variability properties of PG quasars with RXTE

    CERN Document Server

    Guainazzi, M; Giallongo, E; Laor, A; Elvis, M; Siemiginowska, A L

    2000-01-01

    We have monitored with the RXTE PCA the variability pattern of the 2-20 keV flux in four PG quasars (QSOs) from the Laor et al. (1994) sample. Six observations of each target at regular intervals of 1 day were performed. The sample comprises objects with extreme values of Balmer line width (and hence soft X-ray steepness) and spans about one order of magnitude in luminosity. The most robust result is that the variability amplitude decreases as energy increases. Several options for a possible ultimate driver of the soft and hard X-ray variability, such as the influx rate of Comptonizing relativistic particles, instabilities in the accretion flow or the number of X-ray active sites, are consistent with our results.

  5. At-wavelength metrology of hard X-ray mirror using near field speckle.

    Science.gov (United States)

    Berujon, Sebastien; Wang, Hongchang; Alcock, Simon; Sawhney, Kawal

    2014-03-24

    We present a method to measure the surface profile of hard X-ray reflective optics with nanometer height accuracy and sub-millimetre lateral resolution. The technique uses X-ray near-field speckle, generated by a scattering membrane translated using a piezo motor, to infer the deflection of X-rays from the surface. The method provides a nano-radian order accuracy on the mirror slopes in both the tangential and sagittal directions. As a demonstration, a pair of focusing mirrors mounted in a Kirkpatrick-Baez (KB) configuration were characterized and the results were in good agreement with offline metrology data. It is hoped that the new technique will provide feedback to optic manufacturers to improve mirror fabrication and be useful for the online optimization of active, nano-focusing mirrors on modern synchrotron beamlines.

  6. High resolution energy-angle correlation measurement of hard x rays from laser-Thomson backscattering.

    Science.gov (United States)

    Jochmann, A; Irman, A; Bussmann, M; Couperus, J P; Cowan, T E; Debus, A D; Kuntzsch, M; Ledingham, K W D; Lehnert, U; Sauerbrey, R; Schlenvoigt, H P; Seipt, D; Stöhlker, Th; Thorn, D B; Trotsenko, S; Wagner, A; Schramm, U

    2013-09-13

    Thomson backscattering of intense laser pulses from relativistic electrons not only allows for the generation of bright x-ray pulses but also for the investigation of the complex particle dynamics at the interaction point. For this purpose a complete spectral characterization of a Thomson source powered by a compact linear electron accelerator is performed with unprecedented angular and energy resolution. A rigorous statistical analysis comparing experimental data to 3D simulations enables, e.g., the extraction of the angular distribution of electrons with 1.5% accuracy and, in total, provides predictive capability for the future high brightness hard x-ray source PHOENIX (photon electron collider for narrow bandwidth intense x rays) and potential gamma-ray sources.

  7. A microscope for hard x-rays based on parabolic compound refractive lenses

    Science.gov (United States)

    Schroer, C. G.; Lengeler, B.; Benner, B.; Günzler, F.; Tümmler, J.; Drakopoulos, M.; Weitkamp, T.; Snigirev, A.; Snigireva, I.

    2000-05-01

    We describe refractive x-ray lenses with parabolic profile that are genuine imaging devices, similar to glass lenses for visible light. They open considerable possibilities in x-ray microscopy, tomography, microanalysis, and coherent scattering. Based on these lenses a microscope for hard x-rays is described, that can operate in the range from 2 to 60 keV, allowing for magnifications up to 50. At present, using aluminum lenses, it is possible to image an area of about 300μm in diameter with a resolving power of 0.3μm. Using beryllium as a lens material, the resolution can be increased below 0.1μm. The microscope allows to image opaque samples without destructive sample preparation and without the need of a vacuum chamber. It is particularly useful for in situ studies of wet samples, like biological and geological specimens. Imaging in both absorption and phase contrast is possible.

  8. The Variable Crab Nebula: Evidence for a Connection between GeV flares and Hard X-ray Variations

    Science.gov (United States)

    Wilson-Hodge, Colleen A.; Kust Harding, Alice; Hays, Elizabeth A.; Cherry, Michael L.; Case, Gary L.; Finger, Mark H.; Jenke, Peter; Zhang, Xiao-Ling

    2016-04-01

    In 2010, hard X-ray variations (Wilson-Hodge et al. 2011) and GeV flares (Tavani et al 2011, Abdo et al. 2011) from the Crab Nebula were discovered. Connections between these two phenomena were unclear, in part because the timescales were quite different, with yearly variations in hard X-rays and hourly to daily variations in the GeV flares. The hard X-ray flux from the Crab Nebula has again declined since 2014, much like it did in 2008-2010. During both hard X-ray decline periods, the Fermi LAT detected no GeV flares, suggesting that injection of particles from the GeV flares produces the much slower and weaker hard X-ray variations. The timescale for the particles emitting the GeV flares to lose enough energy to emit synchrotron photons in hard X-rays is consistent with the yearly variations observed in hard X-rays and with the expectation that the timescale for variations slowly increases with decreasing energy. This hypothesis also predicts even slower and weaker variations below 10 keV, consistent with the non-detection of counterparts to the GeV flares by Chandra (Weisskopf et al 2013). We will present a comparison of the observed hard X-ray variations and a simple model of the decay of particles from the GeV flares to test our hypothesis.

  9. Center for X-ray Optics, 1988

    Energy Technology Data Exchange (ETDEWEB)

    1989-04-01

    This report briefly reviews the following topics: soft-x-ray imaging; reflective optics for hard x-rays; coherent XUV sources; spectroscopy with x-rays; detectors for coronary artery imaging; synchrotron-radiation optics; and support for the advanced light source.

  10. Silicon Drift Detector for Soft x-ray Spectrometer in Fusion Plasmas

    Institute of Scientific and Technical Information of China (English)

    LI Mei; JU Hong-jun

    2008-01-01

    Silicon drift detector(SDD) is used in the soft x-ray pulse height analyzer(PHA) to measure soft x-ray emissions in fusion plasmas. SDD has the virtues of high count rates and high energy resolution, and the good performances at work temperature of about -10 ℃ achieved by single stage peltier element. The performance and first experimental results from SDD system are presented.

  11. Single-shot x-ray phase imaging with grating interferometry and photon-counting detectors.

    Science.gov (United States)

    Wang, Zhili; Gao, Kun; Wang, Dajiang; Wu, Zhao; Chen, Heng; Wang, Shenghao; Wu, Ziyu

    2014-02-15

    In this Letter, we present a single-shot approach to quantitatively retrieve x-ray absorption and phase shift in grating interferometry. The proposed approach makes use of the energy-resolving capability of x-ray photon-counting detectors. The retrieval method is derived and presented and is tested based on numerical simulations, including photon shot noise. The good agreement between retrieval results and theoretical values confirms the feasibility of the presented approach.

  12. Single-step absorption and phase retrieval with polychromatic x rays using a spectral detector.

    Science.gov (United States)

    Gürsoy, Doğa; Das, Mini

    2013-05-01

    In this Letter, we present a single-step method to simultaneously retrieve x-ray absorption and phase images valid for a broad range of imaging energies and material properties. Our method relies on the availability of spectrally resolved intensity measurements, which is now possible using semiconductor x-ray photon counting detectors. The retrieval method is derived and presented, with results showing good agreement.

  13. A setup for soft proton irradiation of X-ray detectors for future astronomical space missions

    OpenAIRE

    Sebastian DieboldKepler Center for Astro and Particle Physics - University of Tübingen; Philipp Azzarello(ISDC Data Centre for Astrophysics - University of Geneva); Ettore Del Monte(INAF/IASF Istituto di Astrofisica Spaziale e Fisica Cosmica - Rome); Marco Feroci(IAPS-INAF, Roma, Italy); Josef Jochum(Kepler Center for Astro and Particle Physics - University of Tübingen); Eckhard Kendziorra(Kepler Center for Astro and Particle Physics - University of Tübingen); Emanuele Perinati(Kepler Center for Astro and Particle Physics - University of Tübingen); Alexandre Rachevski(INFN Istituto Nazionale di Fisica Nucleare - Sezione di Trieste); Andrea Santangelo(Kepler Center for Astro and Particle Physics - University of Tübingen); Christoph Tenzer(Kepler Center for Astro and Particle Physics - University of Tübingen); Andrea Vacchi(INFN - Sezione di Trieste, Trieste, Italy); Gianluigi Zampa(INFN Istituto Nazionale di Fisica Nucleare - Sezione di Trieste); Nicola Zampa(INFN Istituto Nazionale di Fisica Nucleare - Sezione di Trieste)

    2013-01-01

    Protons that are trapped in the Earth's magnetic field are one of the main threats to astronomical X-ray observatories. Soft protons, in the range from tens of keV up to a few MeV, impinging on silicon X-ray detectors can lead to a significant degradation of the detector performance. Especially in low earth orbits an enhancement of the soft proton flux has been found. A setup to irradiate detectors with soft protons has been constructed at the Van-de-Graaff accelerator of th...

  14. Theoretical consideration of the energy resolution in planar HPGe detectors for low energy X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Samedov, Victor V. [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), 31, Kashirskoye Shosse, 115409, Moscow, (Russian Federation)

    2015-07-01

    In this work, theoretical consideration of the processes in planar High Purity Ge (HPGe) detectors for low energy X-rays using the random stochastic processes formalism was carried out. Using the random stochastic processes formalism, the generating function of the processes of X-rays registration in a planar HPGe detector was derived. The power serial expansions of the detector amplitude and the variance in terms of the inverse bias voltage were derived. The coefficients of these expansions allow determining the Fano factor, electron mobility lifetime product, nonuniformity of the trap density, and other characteristics of the semiconductor material. (authors)

  15. Possibilities and Challenges of Scanning Hard X-ray Spectro-microscopy Techniques in Material Sciences

    Directory of Open Access Journals (Sweden)

    Andrea Somogyi

    2015-06-01

    Full Text Available Scanning hard X-ray spectro-microscopic imaging opens unprecedented possibilities in the study of inhomogeneous samples at different length-scales. It gives insight into the spatial variation of the major and minor components, impurities and dopants of the sample, and their chemical and electronic states at micro- and nano-meter scales. Measuring, modelling and understanding novel properties of laterally confined structures are now attainable. The large penetration depth of hard X-rays (several keV to several 10 keV beam energy makes the study of layered and buried structures possible also in in situ and in operando conditions. The combination of different X-ray analytical techniques complementary to scanning spectro-microscopy, such as X-ray diffraction, X-ray excited optical luminescence, secondary ion mass spectrometry (SIMS and nano-SIMS, provides access to optical characteristics and strain and stress distributions. Complex sample environments (temperature, pressure, controlled atmosphere/vacuum, chemical environment are also possible and were demonstrated, and allow as well the combination with other analysis techniques (Raman spectroscopy, infrared imaging, mechanical tensile devices, etc. on precisely the very same area of the sample. The use of the coherence properties of X-rays from synchrotron sources is triggering emerging experimental imaging approaches with nanometer lateral resolution. New fast analytical possibilities pave the way towards statistically significant studies at multi- length-scales and three dimensional tomographic investigations. This paper gives an overview of these techniques and their recent achievements in the field of material sciences.

  16. Extended hard-X-ray emission in the inner few parsecs of the Galaxy

    DEFF Research Database (Denmark)

    Perez, Kerstin; Hailey, Charles J.; Bauer, Franz E.

    2015-01-01

    The Galactic Centre hosts a puzzling stellar population in its inner few parsecs, with a high abundance of surprisingly young, relatively massive stars bound within the deep potential well of the central supermassive black hole, Sagittarius A* (ref. 1). Previous studies suggest that the populatio...... outflows interacting with the surrounding radiation field, dense molecular material or magnetic fields. However, all these interpretations pose significant challenges to our understanding of stellar evolution, binary formation, and cosmic-ray production in the Galactic Centre....... of objects emitting soft X-rays (less than 10 kiloelectronvolts) within the surrounding hundreds of parsecs, as well as the population responsible for unresolved X-ray emission extending along the Galactic plane, is dominated by accreting white dwarf systems. Observations of diffuse hard-X-ray (more than 10...... range. This emission is more sharply peaked towards the Galactic Centre than is the surface brightness of the soft-X-ray population. This could indicate a significantly more massive population of accreting white dwarfs, large populations of low-mass X-ray binaries or millisecond pulsars, or particle...

  17. Communication: The electronic structure of matter probed with a single femtosecond hard x-ray pulse

    Directory of Open Access Journals (Sweden)

    J. Szlachetko

    2014-03-01

    Full Text Available Physical, biological, and chemical transformations are initiated by changes in the electronic configuration of the species involved. These electronic changes occur on the timescales of attoseconds (10−18 s to femtoseconds (10−15 s and drive all subsequent electronic reorganization as the system moves to a new equilibrium or quasi-equilibrium state. The ability to detect the dynamics of these electronic changes is crucial for understanding the potential energy surfaces upon which chemical and biological reactions take place. Here, we report on the determination of the electronic structure of matter using a single self-seeded femtosecond x-ray pulse from the Linac Coherent Light Source hard x-ray free electron laser. By measuring the high energy resolution off-resonant spectrum (HEROS, we were able to obtain information about the electronic density of states with a single femtosecond x-ray pulse. We show that the unoccupied electronic states of the scattering atom may be determined on a shot-to-shot basis and that the measured spectral shape is independent of the large intensity fluctuations of the incoming x-ray beam. Moreover, we demonstrate the chemical sensitivity and single-shot capability and limitations of HEROS, which enables the technique to track the electronic structural dynamics in matter on femtosecond time scales, making it an ideal probe technique for time-resolved X-ray experiments.

  18. Two distinct phases of hard x-ray emissions in a solar eruptive flare

    CERN Document Server

    Joshi, Bhuwan; Cho, K -S; Bong, S -C; Moon, Y -J; Lee, Jeongwoo; Somov, B V; Manoharan, P K; Kim, Y -H

    2008-01-01

    We present a detailed analysis of the evolution of an M7.6 flare that occurred near the south-east limb on October 24, 2003 utilizing a multi-wavelength data set. Preflare images at TRACE 195 A show that the bright and complex system of coronal loops already existed at the flaring site. The X-ray light curves clearly reveal two phases of flare evolution. The emission during the first phase is seen in GOES and RHESSI measurements at energies below 25 keV, while the second phase is evident in all the X-ray energies as high as 300 keV. The first phase is gradual whereas the second phase shows impulsive emission with several individual hard X-ray bursts. The first phase starts with the appearance of an X-ray loop-top (LT) source in RHESSI images below 25 keV. About 5 minute later, the TRACE 195 A images show an intense emission that is cospatial with RHESSI LT source. This hot and diffuse TRACE emission is attributed to the existence of 15-20 MK plasma, heated directly from the primary energy source. Both X-ray a...

  19. Development of a hard x-ray wavefront sensor for the EuXFEL

    Science.gov (United States)

    Berujon, Sebastien; Ziegler, Eric; Cojocaru, Ruxandra; Martin, Thierry

    2017-05-01

    We present developments on a hard X-ray wavefront sensing instrument for characterizing and monitoring the beam of the European X-ray Free Electron Lasers (EuXFEL). The pulsed nature of the intense X-ray beam delivered by this new class of facility gives rise to strong challenges for the optics and their diagnostic. In the frame of the EUCALL project Work Package 7, we are developing a sensor able to observe the beam in the X-ray energy range [8-40] keV without altering it. The sensor is based on the speckle tracking principle and employs two semi-transparent optics optimized such that their X-ray absorption is reduced. Furthermore, this instrument requires a scattering object with small random features placed in the beam and two cameras to record images of the beam at two different propagation distances. The analysis of the speckle pattern and its distortion from one image to the other allows absolute or differential wavefront recovery from pulse to pulse. Herein, we introduce the stakes and challenges of wavefront sensing at an XFEL source and explain the strategies adopted to fulfil the high requirements set by such a source.

  20. Hard X-ray photoelectron and X-ray absorption spectroscopy characterization of oxidized surfaces of iron sulfides

    Energy Technology Data Exchange (ETDEWEB)

    Mikhlin, Yuri, E-mail: yumikh@icct.ru [Institute of Chemistry and Chemical Technology of the Siberian Branch of the Russian Academy of sciences, Akademgorodok, 50/24, Krasnoyarsk, 660036 (Russian Federation); Tomashevich, Yevgeny [Institute of Chemistry and Chemical Technology of the Siberian Branch of the Russian Academy of sciences, Akademgorodok, 50/24, Krasnoyarsk, 660036 (Russian Federation); Vorobyev, Sergey [Institute of Chemistry and Chemical Technology of the Siberian Branch of the Russian Academy of sciences, Akademgorodok, 50/24, Krasnoyarsk, 660036 (Russian Federation); Siberian Federal University, Svobodny pr. 79, Krasnoyarsk, 660041 (Russian Federation); Saikova, Svetlana [Siberian Federal University, Svobodny pr. 79, Krasnoyarsk, 660041 (Russian Federation); Romanchenko, Alexander [Institute of Chemistry and Chemical Technology of the Siberian Branch of the Russian Academy of sciences, Akademgorodok, 50/24, Krasnoyarsk, 660036 (Russian Federation); Félix, Roberto [Renewable Energy, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Lise-Meitner-Campus, Hahn-Meitner-Platz 1, 14109 Berlin (Germany)

    2016-11-30

    Highlights: • Pyrite and pyrrhotite in-air abraded and etched in aqueous Fe{sup 3+} solution were studied. • HAXPES (2 keV-6 keV) and Fe K-, S K-edge XANES (TEY and PFY mode) were measured. • Outer “polysulfide”, strongly S-excessive layers are no more than 1–4 nm thick. • “Metal-depleted” layers depend on the treatment and differ for pyrite and pyrrhotite. • Extended nearly-stoichiometric “defective” underlayers were detected using TEY XANES. - Abstract: Hard X-ray photoelectron spectroscopy (HAXPES) using an excitation energy range of 2 keV to 6 keV in combination with Fe K- and S K-edge XANES, measured simultaneously in total electron (TEY) and partial fluorescence yield (PFY) modes, have been applied to study near-surface regions of natural polycrystalline pyrite FeS{sub 2} and pyrrhotite Fe{sub 1−x}S before and after etching treatments in an acidic ferric chloride solution. It was found that the following near-surface regions are formed owing to the preferential release of iron from oxidized metal sulfide lattices: (i) a thin, no more than 1–4 nm in depth, outer layer containing polysulfide species, (ii) a layer exhibiting less pronounced stoichiometry deviations and low, if any, concentrations of polysulfide, the composition and dimensions of which vary for pyrite and pyrrhotite and depend on the chemical treatment, and (iii) an extended almost stoichiometric underlayer yielding modified TEY XANES spectra, probably, due to a higher content of defects. We suggest that the extended layered structure should heavily affect the near-surface electronic properties, and processes involving the surface and interfacial charge transfer.

  1. Simulations of an X-Ray Detector Using Geant4

    Science.gov (United States)

    Ertley, Camden; McConnell, Mark; Bloser, Peter; Legere, Jason; Connor, Taylor; Ryan, James

    2009-10-01

    NASA's Black Hole Finder Probe mission has two proposed concepts. CASTER, one of the proposed concepts, is a scintillator based Coded Aperture Survey Telescope for Energetic Radiation. This paper focuses on the development of a simulation that accurately models the proposed CASTER detector. The current detector design consists of a Lanthanum Bromide (LaBr3) scintillator directly coupled to a multianode photomultiplier tube (MAPMT). This detector should be optimized to give the best energy and position resolution. The simulation is based on the Geant4 toolkit, a set of detector simulation tools developed at CERN. Geant4 was chosen because it accurately models radiation devices and detectors, while allowing the simulation of transport and boundary conditions of optical photons. The results of the simulation were compared with data taken in the lab with a ^57Co and an ^241Am source. Once validated, the simulations will be used to optimize the final detector design.

  2. High-energy X-ray diffraction using the Pixium 4700 flat-panel detector.

    Science.gov (United States)

    Daniels, J E; Drakopoulos, M

    2009-07-01

    The Pixium 4700 detector represents a significant step forward in detector technology for high-energy X-ray diffraction. The detector design is based on digital flat-panel technology, combining an amorphous Si panel with a CsI scintillator. The detector has a useful pixel array of 1910 x 2480 pixels with a pixel size of 154 microm x 154 microm, and thus it covers an effective area of 294 mm x 379 mm. Designed for medical imaging, the detector has good efficiency at high X-ray energies. Furthermore, it is capable of acquiring sequences of images at 7.5 frames per second in full image mode, and up to 60 frames per second in binned region of interest modes. Here, the basic properties of this detector applied to high-energy X-ray diffraction are presented. Quantitative comparisons with a widespread high-energy detector, the MAR345 image plate scanner, are shown. Other properties of the Pixium 4700 detector, including a narrow point-spread function and distortion-free image, allows for the acquisition of high-quality diffraction data at high X-ray energies. In addition, high frame rates and shutterless operation open new experimental possibilities. Also provided are the necessary data for the correction of images collected using the Pixium 4700 for diffraction purposes.

  3. Low-energy X-ray detection with an in-vacuum PILATUS detector

    Science.gov (United States)

    Marchal, Julien; Luethi, Benjamin; Ursachi, Catalin; Mykhaylyk, Vitaliy; Wagner, Armin

    2011-11-01

    The feasibility of using PILATUS single-X-ray-photon counting detectors for long-wavelength macromolecular crystallography was investigated by carrying out a series of experiments at Diamond Light Source. A water-cooled PILATUS 100k detector was tested in vacuum with monochromatic 3 keV X-rays on the Diamond test beamline B16. Effects of detector cooling on noise performance, energy calibration and threshold trimming were investigated. When detecting 3 keV X-rays, the electronic noise of the analogue output of pixel preamplifiers forces the threshold to be set at a higher level than the 50% energy level recommended to minimize charge-sharing effects. The influence of threshold settings at low X-ray energy was studied by characterizing the detector response to a collimated beam of 3 keV X-rays scanned across several pixels. The relationship between maximum count rate and minimum energy threshold was investigated separately for various detector gain settings.

  4. X-ray Characterization of a Multichannel Smart-Pixel Array Detector

    Energy Technology Data Exchange (ETDEWEB)

    Ross, Steve; Haji-Sheikh, Michael; Huntington, Andrew; Kline, David; Lee, Adam; Li, Yuelin; Rhee, Jehyuk; Tarpley, Mary; Walko, Donald A.; Westberg, Gregg; Williams, George; Zou, Haifeng; Landahl, Eric

    2016-01-01

    The Voxtel VX-798 is a prototype X-ray pixel array detector (PAD) featuring a silicon sensor photodiode array of 48 x 48 pixels, each 130 mu m x 130 mu m x 520 mu m thick, coupled to a CMOS readout application specific integrated circuit (ASIC). The first synchrotron X-ray characterization of this detector is presented, and its ability to selectively count individual X-rays within two independent arrival time windows, a programmable energy range, and localized to a single pixel is demonstrated. During our first trial run at Argonne National Laboratory's Advance Photon Source, the detector achieved a 60 ns gating time and 700 eV full width at half-maximum energy resolution in agreement with design parameters. Each pixel of the PAD holds two independent digital counters, and the discriminator for X-ray energy features both an upper and lower threshold to window the energy of interest discarding unwanted background. This smart-pixel technology allows energy and time resolution to be set and optimized in software. It is found that the detector linearity follows an isolated dead-time model, implying that megahertz count rates should be possible in each pixel. Measurement of the line and point spread functions showed negligible spatial blurring. When combined with the timing structure of the synchrotron storage ring, it is demonstrated that the area detector can perform both picosecond time-resolved X-ray diffraction and fluorescence spectroscopy measurements.

  5. Hard X-ray polarimetry with Caliste, a high performance CdTe based imaging spectrometer

    Science.gov (United States)

    Antier, S.; Ferrando, P.; Limousin, O.; Caroli, E.; Curado da Silva, R. M.; Blondel, C.; Chipaux, R.; Honkimaki, V.; Horeau, B.; Laurent, P.; Maia, J. M.; Meuris, A.; Del Sordo, S.; Stephen, J. B.

    2015-06-01

    Since the initial exploration of the X- and soft γ-ray sky in the 60's, high-energy celestial sources have been mainly characterized through imaging, spectroscopy and timing analysis. Despite tremendous progress in the field, the radiation mechanisms at work in sources such as neutrons stars, black holes, and Active Galactic Nuclei are still unclear. The polarization state of the radiation is an observational parameter which brings key additional information about the physical processes in these high energy sources, allowing the discrimination between competing models which may otherwise all be consistent with other types of measurement. This is why most of the projects for the next generation of space missions covering the few tens of keV to the MeV region require a polarization measurement capability. A key element enabling this capability, in this energy range, is a detector system allowing the identification and characterization of Compton interactions as they are the main process at play. The compact hard X-ray imaging spectrometer module, developed in CEA with the generic name of "Caliste" module, is such a detector. In this paper, we present experimental results for two types of Caliste-256 modules, one based on a CdTe crystal, the other one on a CdZnTe crystal, which have been exposed to linearly polarized beams at the European Synchrotron Radiation Facility (ESRF). These results, obtained at 200 and 300 keV, demonstrate the capability of these modules to detect Compton events and to give an accurate determination of the polarization parameters (polarization angle and fraction) of the incoming beam. For example, applying an optimized selection to our data set, equivalent to select 90° Compton scattered interactions in the detector plane, we find a modulation factor Q of 0.78 ± 0.06 in the 200-300 keV range. The polarization angle and fraction are derived with accuracies of approximately 1° and 5 % respectively for both CdZnTe and CdTe crystals. The

  6. Study on temperature coefficient of CdTe detector used for X-rays detection

    CERN Document Server

    Guo, Si-Ming; Zhang, Jian; Li, Xu-Fang; Liu, Cong-Zhan; Zhang, Shuai; Li, Cheng-Ze; Huo, Bin-Bin; Liao, Zhen-Yu

    2016-01-01

    The temperature of the working environment is a key factor in determining the properties of semiconductor detectors, and it affects the absolute accuracy and stability of the standard detector. In order to determine the temperature coefficient of CdTe detector used for X-rays detection, a precise temperature control system was designed. In this experiment, detectors and radiographic source were set inside the thermostat with temperature of 0-40 Celsius degree, so that the temperature can be regulated for the test of the temperature coefficient of CdTe detector. Studies had shown that, with the increase of the temperature, the energy resolution and detection efficiency of the CdTe detector would deteriorate, and under 10 Celsius degree the detectors have better performance with the 8 keV X-rays.

  7. Weak Hard X-Ray Emission from Two Broad Absorption Line Quasars Observed with NuStar: Compton-Thick Absorption or Intrinsic X-Ray Weakness?

    Science.gov (United States)

    Luo, B.; Brandt, W. N.; Alexander, D. M.; Harrison, F. A.; Stern, D.; Bauer, F. E.; Boggs, S. E.; Christensen, F. E.; Comastri, A.; Craig, W. W..; Fabian, A. C.; Farrah, D.; Fiore, F.; Fuerst, F.; Grefenstette, B. W.; Hailey, C. J.; Hickox, R.; Madsen, K. K.; Matt, G.; Ogle, P.; Risaliti, G.; Saez, C.; Teng, S. H.; Walton, D. J.; Zhang, W. W.

    2013-01-01

    We present Nuclear Spectroscopic Telescope Array (NuSTAR) hard X-ray observations of two X-ray weak broad absorption line (BAL) quasars, PG 1004+130 (radio loud) and PG 1700+518 (radio quiet). Many BAL quasars appear X-ray weak, probably due to absorption by the shielding gas between the nucleus and the accretion-disk wind. The two targets are among the optically brightest BAL quasars, yet they are known to be significantly X-ray weak at rest-frame 2-10 keV (16-120 times fainter than typical quasars). We would expect to obtain approx. or equal to 400-600 hard X-ray (is greater than or equal to 10 keV) photons with NuSTAR, provided that these photons are not significantly absorbed N(sub H) is less than or equal to 10(exp24) cm(exp-2). However, both BAL quasars are only detected in the softer NuSTAR bands (e.g., 4-20 keV) but not in its harder bands (e.g., 20-30 keV), suggesting that either the shielding gas is highly Compton-thick or the two targets are intrinsically X-ray weak. We constrain the column densities for both to be N(sub H) 7 × 10(exp 24) cm(exp-2) if the weak hard X-ray emission is caused by obscuration from the shielding gas. We discuss a few possibilities for how PG 1004+130 could have Compton-thick shielding gas without strong Fe Ka line emission; dilution from jet-linked X-ray emission is one likely explanation. We also discuss the intrinsic X-ray weakness scenario based on a coronal-quenching model relevant to the shielding gas and disk wind of BAL quasars. Motivated by our NuSTAR results, we perform a Chandra stacking analysis with the Large Bright Quasar Survey BAL quasar sample and place statistical constraints upon the fraction of intrinsically X-ray weak BAL quasars; this fraction is likely 17%-40%.

  8. Hard X-ray spectroscopic nano-imaging of hierarchical functional materials at work.

    Science.gov (United States)

    Andrews, Joy C; Weckhuysen, Bert M

    2013-11-11

    Heterogeneous catalysts often consist of an active metal (oxide) in close contact with a support material and various promoter elements. Although macroscopic properties, such as activity, selectivity and stability, can be assessed with catalyst performance testing, the development of relevant, preferably quantitative structure-performance relationships require the use of advanced characterisation methods. Spectroscopic imaging in the hard X-ray region with nanometer-scale resolution has very recently emerged as a powerful approach to elucidate the hierarchical structure and related chemistry of catalytic solids in action under realistic reaction conditions. This X-ray-based chemical imaging method benefits from the combination of high resolution (∼30 nm) with large X-ray penetration and depth of focus, and the possibility for probing large areas with mosaic imaging. These capabilities make it possible to obtain spatial and temporal information on chemical changes in catalytic solids as well as a wide variety of other functional materials, such as fuel cells and batteries, in their full complexity and integrity. In this concept article we provide details on the method and setup of full-field hard X-ray spectroscopic imaging, illustrate its potential for spatiotemporal chemical imaging by making use of recent showcases, outline the pros and cons of this experimental approach and discuss some future directions for hierarchical functional materials research.

  9. Hard x-ray telescopes to be onboard ASTRO-H.

    Science.gov (United States)

    Awaki, Hisamitsu; Kunieda, Hideyo; Ishida, Manabu; Matsumoto, Hironori; Babazaki, Yasunori; Demoto, Tadatsugu; Furuzawa, Akihiro; Haba, Yoshito; Hayashi, Takayuki; Iizuka, Ryo; Ishibashi, Kazunori; Ishida, Naoki; Itoh, Masayuki; Iwase, Toshihiro; Kosaka, Tatsuro; Kurihara, Daichi; Kuroda, Yuuji; Maeda, Yoshitomo; Meshino, Yoshifumi; Mitsuishi, Ikuyuki; Miyata, Yuusuke; Miyazawa, Takuya; Mori, Hideyuki; Nagano, Housei; Namba, Yoshiharu; Ogasaka, Yasushi; Ogi, Keiji; Okajima, Takashi; Saji, Shigetaka; Shimasaki, Fumiya; Sato, Takuro; Sato, Toshiki; Sugita, Satoshi; Suzuki, Yoshio; Tachibana, Kenji; Tachibana, Sasagu; Takizawa, Shunya; Tamura, Keisuke; Tawara, Yuzuru; Torii, Tatsuharu; Uesugi, Kentato; Yamashita, Koujun; Yamauchi, Shigeo

    2014-11-10

    The new Japanese x-ray astronomy satellite, ASTRO-H, will carry two identical hard x-ray telescopes (HXTs), which cover the energy range of 5 to 80 keV. The HXT mirrors employ tightly nested, conically approximated thin-foil Wolter-I optics, and the mirror surfaces are coated with Pt/C depth-graded multilayers to enhance the hard x-ray effective area by means of Bragg reflection. The HXT comprises foils 120-450 mm in diameter and 200 mm in length, with a focal length of 12 m. To obtain a large effective area, 213 aluminum foils 0.2 mm in thickness are tightly nested confocally. The requirements for HXT are a total effective area of >300  cm2 at 30 keV and an angular resolution of ' in half-power diameter (HPD). Fabrication of two HXTs has been completed, and the x-ray performance of each HXT was measured at a synchrotron radiation facility, SPring-8 BL20B2 in Japan. Angular resolutions (HPD) of 1.9' and 1.8' at 30 keV were obtained for the full telescopes of HXT-1 and HXT-2, respectively. The total effective area of the two HXTs at 30 keV is 349  cm2.

  10. A novel synthesis of polymeric CO via useful hard X-ray photochemistry

    Directory of Open Access Journals (Sweden)

    Michael Pravica

    2016-12-01

    Full Text Available We report on the synchrotron hard X-ray-induced decomposition of strontium oxalate (SrC2O4 pressurized to 7 GPa inside a diamond anvil cell (DAC. After some 4 h of irradiation in a white X-ray synchrotron beam, a dark reddish/brown region formed in the area of irradiation which was surrounded by a yellowish brown remainder in the rest of the sample. Upon depressurization of the sample to ambient conditions, the reacted/decomposed sample was recoverable as a dark brown/red and yellow waxy solid. Synchrotron infrared spectroscopy confirmed the strong presence of CO2 even under ambient conditions with the sample exposed to air and other strongly absorbing regions, suggesting that the sample may likely be polymerized CO (in part with dispersed CO2 and SrO trapped within the polymer. These results will have significant implications in the ability to readily produce and trap CO2 in situ via irradiation of a simple powder for useful hard X-ray photochemistry and in the ability to easily manufacture polymeric CO (via loading of powders in a DAC or high volume press without the need for the dangerous and complex loading of toxic CO. A novel means of X-ray-induced polymerization under extreme conditions has also been demonstrated.

  11. Development of the hard x-ray monitor onboard WF-MAXI

    Science.gov (United States)

    Arimoto, Makoto; Yatsu, Yoichi; Kawai, Nobuyuki; Ikeda, Hirokazu; Harayama, Atsushi; Takeda, Shin'ichiro; Takahashi, Tadayuki; Tomida, Hiroshi; Ueno, Shiro; Kimura, Masashi; Mihara, Tatehiro; Serino, Motoko; Tsunemi, Hiroshi; Yoshida, Atsumasa; Sakamoto, Takanori; Kohmura, Tadayoshi; Negoro, Hitoshi; Ueda, Yoshihiro

    2014-07-01

    WF-MAXI is a mission to detect and localize X-ray transients with short-term variability as gravitational-wave (GW) candidates including gamma-ray bursts, supernovae etc. We are planning on starting observations by WF-MAXI to be ready for the initial operation of the next generation GW telescopes (e.g., KAGRA, Advanced LIGO etc.). WF-MAXI consists of two main instruments, Soft X-ray Large Solid Angle Camera (SLC) and Hard X-ray Monitor (HXM) which totally cover 0.7 keV to 1 MeV band. HXM is a multi-channel array of crystal scintillators coupled with APDs observing photons in the hard X-ray band with an effective area of above 100 cm2. We have developed an analog application specific integrated circuit (ASIC) dedicated for the readout of 32-channel APDs' signals using 0.35 μm CMOS technology based on Open IP project and an analog amplifier was designed to achieve a low-noise readout. The developed ASIC showed a low-noise performance of 2080 e- + 2.3 e-/pF at root mean square and with a reverse-type APD coupled to a Ce:GAGG crystal a good FWHM energy resolution of 6.9% for 662 keV -rays.

  12. Hard X-ray Emission From A Flare-related Jet

    Science.gov (United States)

    Bain, Hazel; Fletcher, L.

    2009-05-01

    Solar X-ray jets were first observed by Yohkoh (Shibata 1992, Strong 1992). During these events, collimated flows of plasma are accelerated in the corona. Previous observations have detected jet-related electrons directly in space as well as via radio signatures (type III bursts). However the major diagnostic of fast electrons is bremsstrahlung X-ray emission, but until now we have never seen any evidence of hard X-ray emission directly from the jet in the corona. This could be because it is rare to find a coronal jet dense enough to provide a bremsstrahlung target for the electrons, or hot enough to generate high energy thermal emission. We report what we believe to be the first observation of hard X-ray emission formed in a coronal jet. The event occurred on the 22nd of August 2002 and its evolution was observed by a number of instruments. In particular we study the pre-impulsive and impulsive phase of the flare using data from RHESSI, TRACE and the Nobeyama Radioheliograph. During this period RHESSI observed significant hard X-ray emission to energies as high as 50 keV in the jet. Radio observations from the Nobeyama Radioheliograph show a positive spectral index for the ejected material, which may be explained by optically-thick gyrosynchrotron emission from non-thermal electrons in the jet. HMB gratefully acknowledges the support of an SPD and STFC studentship. LF gratefully acknowledges the support of an STFC Rolling Grant, and financial support by the European Commission through the SOLAIRE Network (MTRN-CT_2006-035484)

  13. New developments for the investigation of hard X-rays emitted by peeling adhesive tapes

    Science.gov (United States)

    Krämer, D.; Lützenkirchen-Hecht, D.; Lühmann, B.; Keite-Telgenbüscher, K.; Frahm, R.

    2013-05-01

    We realized an advanced apparatus for the investigation of emitted X-rays produced by peeling adhesive tape rolls under vacuum conditions. Two stepper motors can unwind and rewind a tape roll, and an additional roller with an optical encoder provides measurement and control of the tape speed. This way reproducible and consecutive experiments are feasible without having to change the tape or break the vacuum. The dependence of the X-ray emission on tape speed, gas pressure, type of adhesive tape, and detector angle has been investigated. The resulting spectra are continuous and span an X-ray energy range of typically 2-60 keV with high intensity. Furthermore, the new apparatus allows the in situ metalization of adhesive tape rolls by a gold sputter source. A significantly increased X-ray emission was observed for adhesive tapes with a metal coating. Thin metal foils have been placed between the tape and the detector, different K- and L-absorption edges could be measured. A considerable enhancement of the emission was achieved under the influence of the magnetic field of an NdFeB permanent magnet.

  14. Analytic model of energy-absorption response functions in compound X-ray detector materials.

    Science.gov (United States)

    Yun, Seungman; Kim, Ho Kyung; Youn, Hanbean; Tanguay, Jesse; Cunningham, Ian A

    2013-10-01

    The absorbed energy distribution (AED) in X-ray imaging detectors is an important factor that affects both energy resolution and image quality through the Swank factor and detective quantum efficiency. In the diagnostic energy range (20-140 keV), escape of characteristic photons following photoelectric absorption and Compton scatter photons are primary sources of absorbed-energy dispersion in X-ray detectors. In this paper, we describe the development of an analytic model of the AED in compound X-ray detector materials, based on the cascaded-systems approach, that includes the effects of escape and reabsorption of characteristic and Compton-scatter photons. We derive analytic expressions for both semi-infinite slab and pixel geometries and validate our approach by Monte Carlo simulations. The analytic model provides the energy-dependent X-ray response function of arbitrary compound materials without time-consuming Monte Carlo simulations. We believe this model will be useful for correcting spectral distortion artifacts commonly observed in photon-counting applications and optimal design and development of novel X-ray detectors.

  15. Two-dimensional imaging detectors for structural biology with X-ray lasers.

    Science.gov (United States)

    Denes, Peter

    2014-07-17

    Our ability to harness the advances in microelectronics over the past decade(s) for X-ray detection has resulted in significant improvements in the state of the art. Biology with X-ray free-electron lasers present daunting detector challenges: all of the photons arrive at the same time, and individual high peak power pulses must be read out shot-by-shot. Direct X-ray detection in silicon pixel detectors--monolithic or hybrid--are the standard for XFELs today. For structural biology, improvements are needed for today's 10-100 Hz XFELs, and further improvements are required for tomorrow's 10+ kHz XFELs. This article will discuss detector challenges, why they arise and ways to overcome them, along with the current state of the art. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  16. X-ray imaging with photon counting hybrid semiconductor pixel detectors

    CERN Document Server

    Manolopoulos, S; Campbell, M; Snoeys, W; Heijne, Erik H M; Pernigotti, E; Raine, C; Smith, K; Watt, J; O'Shea, V; Ludwig, J; Schwarz, C

    1999-01-01

    Semiconductor pixel detectors, originally developed for particle physics experiments, have been studied as X-ray imaging devices. The performance of devices using the OMEGA 3 read-out chip bump-bonded to pixellated silicon semiconductor detectors is characterised in terms of their signal-to-noise ratio when exposed to 60 kVp X-rays. Although parts of the devices achieve values of this ratio compatible with the noise being photon statistics limited, this is not found to hold for the whole pixel matrix, resulting in the global signal-to-noise ratio being compromised. First results are presented of X-ray images taken with a gallium arsenide pixel detector bump-bonded to a new read-out chip, (MEDIPIX), which is a single photon counting read-out chip incorporating a 15-bit counter in every pixel. (author)

  17. X-ray imaging with photon counting hybrid semiconductor pixel detectors

    Energy Technology Data Exchange (ETDEWEB)

    Manolopoulos, S.; Bates, R.; Campbell, M.; Snoeys, W.; Heijne, E.; Pernigotti, E.; Raine, C.; Smith, K. E-mail: k.smith@physics.gla.ac.uk; Watt, J.; O' Shea, V.; Ludwig, J.; Schwarz, C

    1999-09-11

    Semiconductor pixel detectors, originally developed for particle physics experiments, have been studied as X-ray imaging devices. The performance of devices using the {omega}3 read-out chip bump-bonded to pixellated silicon semiconductor detectors is characterised in terms of their signal-to-noise ratio when exposed to 60 kVp X-rays. Although parts of the devices achieve values of this ratio compatible with the noise being photon statistics limited, this is not found to hold for the whole pixel matrix, resulting in the global signal-to-noise ratio being compromised. First results are presented of X-ray images taken with a gallium arsenide pixel detector bump-bonded to a new read-out chip, (MEDIPIX), which is a single photon counting read-out chip incorporating a 15-bit counter in every pixel. (author)

  18. A study of hard X-ray associated meter-decameter bursts observed on December 19, 1979

    Science.gov (United States)

    Kundu, M. R.; Gergely, T. E.; Kane, S. R.; Sawant, H. S.

    1986-01-01

    The results of a study of the relationship of a complex meter-decameter wavelength radio burst observed with the Clark Lake E-W and N-S interferometers, with a hard X-ray burst observed with the X-ray spectrometer aboard ISEE-3 are presented. The radio burst consisted of several type III's, reverse drift type III's, a U burst, and type II and type IV bursts. The X-ray emission was also complex. The radio as well as hard X-ray emissions were observed before the flash phase of the flare; they were not always associated and it is conjectured that this may constitute evidence for acceleration of electrons high in the corona. On the other hand, all components of the reverse drift burst were associated with hard X-ray subpeaks, indicating multiple injection of electron beams along field lines with different density gradients. While the type II burst appeared to be related to the hard X-ray burst, a detailed correspondence between individual features of the radio and hard X-ray burst emissions could not be found. The type IV burst started after all hard X-ray emissions ceased. Its source appeared to be a magnetic arch, presumably containing energetic electrons reponsible for the gyrosynchrotron radiation of type IV.

  19. Weak Hard X-ray Emission from Broad Absorption Line Quasars: Evidence for Intrinsic X-ray Weakness

    CERN Document Server

    Luo, B; Alexander, D M; Stern, D; Teng, S H; Arévalo, P; Bauer, F E; Boggs, S E; Christensen, F E; Comastri, A; Craig, W W; Farrah, D; Gandhi, P; Hailey, C J; Harrison, F A; Koss, M; Ogle, P; Puccetti, S; Saez, C; Scott, A E; Walton, D J; Zhang, W W

    2014-01-01

    We report NuSTAR observations of a sample of six X-ray weak broad absorption line (BAL) quasars. These targets, at z=0.148-1.223, are among the optically brightest and most luminous BAL quasars known at z330 times weaker than expected for typical quasars. Our results from a pilot NuSTAR study of two low-redshift BAL quasars, a Chandra stacking analysis of a sample of high-redshift BAL quasars, and a NuSTAR spectral analysis of the local BAL quasar Mrk 231 have already suggested the existence of intrinsically X-ray weak BAL quasars, i.e., quasars not emitting X-rays at the level expected from their optical/UV emission. The aim of the current program is to extend the search for such extraordinary objects. Three of the six new targets are weakly detected by NuSTAR with 33%) of intrinsically X-ray weak objects among the BAL quasars with significantly weak <10 keV emission. We suggest that intrinsically X-ray weak quasars might be preferentially observed as BAL quasars.

  20. Hard X-ray photoemission spectroscopy of transition-metal oxide thin films and interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Wadati, H., E-mail: wadati@ap.t.u-tokyo.ac.jp [Department of Applied Physics and Quantum-Phase Electronics Center (QPEC), University of Tokyo, Hongo, Tokyo 113-8656 (Japan); Fujimori, A. [Department of Physics, University of Tokyo, Bunkyo-ku, Tokyo 113-0033 (Japan)

    2013-10-15

    Highlights: •Photoemission spectroscopy is a powerful technique to study the electronic structures of transition-metal oxides. •Hard X-ray photoemission spectroscopy (HXPES) is a new type of photoemission spectroscopy which can probe bulk states. •HXPES is very suitable for studying oxide thin films such as the composition dependence and the film thickness dependence. -- Abstract: Photoemission spectroscopy is a powerful experimental technique to study the electronic structures of solids, especially of transition-metal oxides. Recently, hard X-ray photoemission spectroscopy (HXPES) has emerged as a more relevant experimental technique to obtain clear information about bulk states. Here, we describe how HXPES can be conveniently applied to study the interesting subjects on oxide thin films such as the composition dependence and the film thickness dependence of the electronic structures and the interfacial electronic structure of multilayers.

  1. Hard X-ray optics simulation using the coherent mode decomposition of Gaussian Schell model

    CERN Document Server

    Hua, Wenqiang; Song, Li; Li, Xiuhong; Wang, Jie

    2013-01-01

    The propagation of hard X ray beam from partially coherent synchrotron source is simulated by using the novel method based on the coherent mode decomposition of Gaussian Schell model and wave front propagation. We investigate how the coherency properties and intensity distributions of the beam are changed by propagation through optical elements. Here, we simulate and analyze the propagation of the partially coherent radiation transmitted through an ideal slit. We present the first simulations for focusing partially coherent synchrotron hard X ray beams using this novel method. And when compared with the traditional method which assumes the source is a totally coherent point source or completely incoherent, this method is proved to be more reasonable and can also demonstrate the coherence properties of the focusing beam. We also simulate the double slit experiment and the simulated results validate the academic analysis.

  2. Development of thermally formed glass optics for astronomical hard X-ray telescopes

    DEFF Research Database (Denmark)

    Craig, W.W.; Hailey, C.J.; Jimenez-Garate, M.

    2000-01-01

    The next major observational advance in hard X-ray/soft gamma-ray astrophysics will come with the implementation of telescopes capable of focusing 10-200 keV radiation. Focusing allows high signal-to-noise imaging and spectroscopic observations of many sources in this band for the first time....... The recent development of depth-graded multilayer coatings has made the design of telescopes for this bandpass practical, however the ability to manufacture inexpensive substrates with appropriate surface quality and figure to achieve sub-arcminute performance has remained an elusive goal. In this paper, we...... report on new, thermally-formed glass micro-sheet optics capable of meeting the requirements of the next-generation of astronomical hard X-ray telescopes....

  3. Multimodality hard-x-ray imaging of a chromosome with nanoscale spatial resolution

    Science.gov (United States)

    Yan, Hanfei; Nazaretski, Evgeny; Lauer, Kenneth; Huang, Xiaojing; Wagner, Ulrich; Rau, Christoph; Yusuf, Mohammed; Robinson, Ian; Kalbfleisch, Sebastian; Li, Li; Bouet, Nathalie; Zhou, Juan; Conley, Ray; Chu, Yong S.

    2016-02-01

    We developed a scanning hard x-ray microscope using a new class of x-ray nano-focusing optic called a multilayer Laue lens and imaged a chromosome with nanoscale spatial resolution. The combination of the hard x-ray’s superior penetration power, high sensitivity to elemental composition, high spatial-resolution and quantitative analysis creates a unique tool with capabilities that other microscopy techniques cannot provide. Using this microscope, we simultaneously obtained absorption-, phase-, and fluorescence-contrast images of Pt-stained human chromosome samples. The high spatial-resolution of the microscope and its multi-modality imaging capabilities enabled us to observe the internal ultra-structures of a thick chromosome without sectioning it.

  4. A practical method to generate brilliant hard x-rays with a tabletop electron storage ring

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, H. [Ritsumeikan Univ., Shiga (Japan); Amano, D.; Miyade, H. [Sumitomo Heavy Industries, Ltd., Tanashi-City (Japan)

    1995-12-31

    With electron storage rings not only synchrotron radiation(SR) but also bremsstrahlung(BS) from a thin target placed in the electron orbit are mechanisms to generate brilliant x-ray beams. The calculated brilliance of BS with a 50 MeV storage ring, which is nearly 10{sup 13} photons/s, mrad{sup 2}, mm{sup 2}, 0.1% band width for 100 keV x-rays, exceeds that of SR from a 1 GeV storage ring. This photon energy spectrum is almost constant and extend up to the electron energy. The reasons for this high brilliance with this new radiation scheme is that the electron beams penetrating the thin target are utilized repeatedly, the narrow angular divergence of BS is determined by the kinematics of relativistic electron as same as SR, and the x-ray source size of the order of 1 {mu}m is determined by the size of thin target instead of electron beam sizes. Continuous injection of electron beam to the storage ring at full energy is the way to keep high and constant beam current. Peak current and repetition rate determine x-ray out put power. Note that the power of x-ray beam is also provided from a RF cavity of the storage ring. In this paper we will report some experimental results and discuss further application on a coherent bremsstrahlung generated from a set of stacked foils placed in the electron orbit of the ring. Resulting from these investigations the photon storage ring which is based on a 50 MeV exact circular electron storage ring could provide wide range of coherent and incoherent radiations from far infrared to hard x-ray in a practical amount of radiation power.

  5. A Hard X-ray Study of the Normal Star-Forming Galaxy M83 with NuSTAR

    CERN Document Server

    Yukita, M; Lehmer, B D; Ptak, A; Wik, D R; Zezas, A; Antoniou, V; Maccarone, T J; Replicon, V; Tyler, J B; Venters, T; Argo, M K; Bechtol, K; Boggs, S; Christensen, F E; Craig, W W; Hailey, C; Harrison, F; Krivonos, R; Kuntz, K; Stern, D; Zhang, W W

    2016-01-01

    We present results from sensitive, multi-epoch NuSTAR observations of the late-type star-forming galaxy M83 (d=4.6 Mpc), which is the first investigation to spatially resolve the hard (E>10 keV) X-ray emission of this galaxy. The nuclear region and ~ 20 off-nuclear point sources, including a previously discovered ultraluminous X-ray (ULX) source, are detected in our NuSTAR observations. The X-ray hardnesses and luminosities of the majority of the point sources are consistent with hard X-ray sources resolved in the starburst galaxy NGC 253. We infer that the hard X-ray emission is most likely dominated by intermediate accretion state black hole binaries and neutron star low-mass X-ray binaries (Z-sources). We construct the X-ray binary luminosity function (XLF) in the NuSTAR band for an extragalactic environment for the first time. The M83 XLF has a steeper XLF than the X-ray binary XLF in NGC 253, consistent with previous measurements by Chandra at softer X-ray energies. The NuSTAR integrated galaxy spectrum ...

  6. Measurement of 238U muonic x-rays with a germanium detector setup

    Energy Technology Data Exchange (ETDEWEB)

    Esch, Ernst I [Los Alamos National Laboratory; Jason, Andrew [Los Alamos National Laboratory; Miyadera, Haruo [Los Alamos National Laboratory; Hoteling, Nathan J [Los Alamos National Laboratory; Heffner, Robert H [Los Alamos National Laboratory; Adelmann, Andreas [PAUL SCHERRER INSTITUT; Stocki, Trevor [HEALTH CANADA; Mitchell, Lee [NAVAL RESEARCH LAB

    2009-01-01

    In the field of nuclear non-proliferation muon interactions with materials are of great interest. This paper describes an experiment conducted at the Paul Scherrer Institut (PSI) in Switzerland where a muon beam is stopped in a uranium target. The muons produce characteristic muonic x-rays. Muons will penetrate shielding easily and the produced characteristic x-rays can be used for positive isotope identification. Furthermore, the x-rays for uranium isotopes lie in the energy range of 6-7 MeV, which allows them to have an almost optimal mean free path in heavy shielding such as lead or steel. A measurement was conducted at PSI to prove the feasibility of detecting muonic x-rays from a large sample of depleted uranium (several kilograms) with a germanium detector. In this paper, the experimental setup and analysis of the measurement itself is presented.

  7. AGN in the Swift/BAT and INTEGRAL Hard X-ray Surveys

    Science.gov (United States)

    Beckmann, Volker; Tueller, Jack; Baumgartner, Wayne; Markwardt, Craig; Mushotzky, Richard; Skinner, Gerry

    2008-01-01

    Two hard X-ray surveys are in progress at this time. They provide a unique new window on compact objects and black holes. I will discuss how these two surveys complement each other and the potential for improved coordination that could yield significant near term results in both sensitivity and time coverage. I will pay particular attention to the discovery of faint sources including new results from the 36 month survey from Swift/Burst Alert Telescope (BAT).

  8. Self-standing quasi-mosaic crystals for focusing hard X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Camattari, Riccardo; Guidi, Vincenzo; Bellucci, Valerio; Neri, Ilaria; Frontera, Filippo [Department of Physics and Earth Science, University of Ferrara, Via Saragat 1/c, 44122 Ferrara (Italy); CNR-IDASC SENSOR Lab. (Italy); Jentschel, Michael [Institut Laue Langevin, F-38042 Grenoble Cedex (France)

    2013-05-15

    A quasi mosaic bent crystal for high-resolution diffraction of X and {gamma} rays has been realized. A net curvature was imprinted to the crystal thanks to a series of superficial grooves to keep the curvature without external devices. The crystal highlights very high diffraction efficiency due to quasi mosaic curvature. Quasi mosaic crystals of this kind are proposed for the realization of a high-resolution focusing Laue lens for hard X-rays.

  9. A new hard X-ray transient discovered by INTEGRAL: IGR J17559-2612

    DEFF Research Database (Denmark)

    Esposito, V.; Ferrigno, C.; Bozzo, E.;

    2012-01-01

    INTEGRAL discovered a new hard X-ray transient, IGR J17559-2612, during the Galactic center observations performed from 2012-08-14 00:02:14 to 2012-08-14 14:45:54 UTC. The source is detected in the IBIS/ISGRI mosaic at a significance level of 8 σ (observation good time: 50 ks) both in the 20-40 k...

  10. Fast temporal correlation between hard X-ray and ultraviolet continuum brightenings

    Science.gov (United States)

    Machado, Marcos E.; Mauas, Pablo J.

    1986-01-01

    Recent Solar Maximum Mission (SMM) observations have shown fast and simultaneous increases in hard X-rays (HXR, E25 keV) and ultraviolet continuum (UVC, lambda lambda approx. equals 1600 and 1388 A) radiation. A simple and natural explanation is given for this phenomenon to happen, which does not involve extreme conditions for energy transport processes, and confirms earlier results on the effect of XUV photoionization in the solar atmosphere.

  11. AGN in the Swift/BAT and INTEGRAL Hard X-ray Surveys

    Science.gov (United States)

    Beckmann, Volker; Tueller, Jack; Baumgartner, Wayne; Markwardt, Craig; Mushotzky, Richard; Skinner, Gerry

    2008-01-01

    Two hard X-ray surveys are in progress at this time. They provide a unique new window on compact objects and black holes. I will discuss how these two surveys complement each other and the potential for improved coordination that could yield significant near term results in both sensitivity and time coverage. I will pay particular attention to the discovery of faint sources including new results from the 36 month survey from Swift/Burst Alert Telescope (BAT).

  12. Photovoltaic x-ray detectors based on the GaAs epitaxial structures

    CERN Document Server

    Akhmadullin, R A; Dvoryankina, G G; Dikaev, Y M; Ermakov, M G; Ermakova, O N; Krikunov, A I; Kudryashov, A A; Petrov, A G; Telegin, A A

    2002-01-01

    The new photovoltaic detector of the X-ray radiation is proposed on the basis of the GaAs epitaxial structures, which operates with high efficiency of the charge carriers collection without shift voltage and at the room temperature. The structures are grown by the method of the gas-phase epitaxy on the n sup + -type highly-alloyed substrates. The range of sensitivity to the X-ray radiation is within the range of effective energies from 8 up to 120 keV. The detector maximum response in the current short circuit mode is determined

  13. Energy-resolved X-ray detectors: the future of diagnostic imaging

    OpenAIRE

    Pacella D

    2015-01-01

    Danilo Pacella ENEA-Frascati, Rome, Italy Abstract: This paper presents recent progress in the field of X-ray detectors, which could play a role in medical imaging in the near future, with special attention to the new generation of complementary metal-oxide semiconductor (C-MOS) imagers, working in photon counting, that opened the way to the energy-resolved X-ray imaging. A brief description of the detectors used so far in medical imaging (photographic films, imaging plates, flat panel detec...

  14. The generation of rapid solar flare hard X-ray and microwave fluctuations in current sheets

    Science.gov (United States)

    Holman, Gordon D.

    The generation of rapid fluctuations, or spikes, in hard X-ray and microwave bursts via the disruption of electron heating and acceleration in current sheets is studied. It is found that 20 msec hard X-ray fluctuations can be thermally generated in a current sheet if the resistivity in the sheet is highly anomalous, the plasma density in the emitting region is relatively high, and the volume of the emitting region is greater than that of the current sheet. A specific mechanism for producing the fluctuations, involving heating in the presence of ion acoustic turbulence and a constant driving electric field, and interruption of the heating by a strong two-stream instability, is discussed. Variations upon this mechanism are also discussed. This mechanism also modulates electron acceleration, as required for the microwave spike emission. If the hard X-ray emission at energies less than approx. 1000 keV is nonthermal bremsstrahlung, the coherent modulation of electron acceleration in a large number of current sheets is required.

  15. Fundamental x-ray interaction limits in diagnostic imaging detectors: spatial resolution.

    Science.gov (United States)

    Hajdok, G; Battista, J J; Cunningham, I A

    2008-07-01

    The practice of diagnostic x-ray imaging has been transformed with the emergence of digital detector technology. Although digital systems offer many practical advantages over conventional film-based systems, their spatial resolution performance can be a limitation. The authors present a Monte Carlo study to determine fundamental resolution limits caused by x-ray interactions in four converter materials: Amorphous silicon (a-Si), amorphous selenium, cesium iodide, and lead iodide. The "x-ray interaction" modulation transfer function (MTF) was determined for each material and compared in terms of the 50% MTF spatial frequency and Wagner's effective aperture for incident photon energies between 10 and 150 keV and various converter thicknesses. Several conclusions can be drawn from their Monte Carlo study. (i) In low-Z (a-Si) converters, reabsorption of Compton scatter x rays limits spatial resolution with a sharp MTF drop at very low spatial frequencies (x rays plays a dominant role, resulting in a mid-frequency (1-5 cycles/mm) MTF drop. (ii) Coherent scatter plays a minor role in the x-ray interaction MTF. (iii) The spread of energy due to secondary electron (e.g., photoelectrons) transport is significant only at very high spatial frequencies. (iv) Unlike the spread of optical light in phosphors, the spread of absorbed energy from x-ray interactions does not significantly degrade spatial resolution as converter thickness is increased. (v) The effective aperture results reported here represent fundamental spatial resolution limits of the materials tested and serve as target benchmarks for the design and development of future digital x-ray detectors.

  16. Optimizing detector geometry for trace element mapping by X-ray fluorescence.

    Science.gov (United States)

    Sun, Yue; Gleber, Sophie-Charlotte; Jacobsen, Chris; Kirz, Janos; Vogt, Stefan

    2015-05-01

    Trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non-fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. We conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90° to the beam versus a larger detector at 180° (in a backscatter-like geometry), the 90° detector is better for trace element detection in thick samples, while the larger detector in 180° geometry is better suited to trace element detection in thin samples.

  17. The hard X-ray response of HgI sub 2

    CERN Document Server

    Owens, A; Brammertz, G; Krumrey, M; Martin, D; Peacock, A; Troeger, L

    2002-01-01

    We summarise the results of a number of X-ray measurements on a 7 mm sup 2 , 0.5 mm thick HgI sub 2 detector carried out both in our laboratory and at two synchrotron radiation facilities in Germany. The detector energy response function was found to be linear over the energy range 2.3-100 keV with an average rms non-linearity of 0.2%. Using a 50x50 mu m sup 2 15 keV monoenergetic X-ray beam, the spatial uniformity of the detector response was determined by a raster scan technique to be better than 1%. At room temperature, the FWHM energy resolution was 600 eV at 5.9 keV rising to 6 keV at 100 keV with no statistically significant difference between pencil beam (50x50 mu m sup 2) and full-area illumination. It was found that the FWHM energy resolution decreased with decreasing temperature reaching a minimum of 400 eV for 5.9 keV X-ray illumination at -19.2 deg. C. Below this temperature, the FWHM begins to rise slowly. By considering the various contributions to the FWHM energy resolution, we estimate the cha...

  18. Energy calibration of the pixels of spectral X-ray detectors.

    Science.gov (United States)

    Panta, Raj Kumar; Walsh, Michael F; Bell, Stephen T; Anderson, Nigel G; Butler, Anthony P; Butler, Philip H

    2015-03-01

    The energy information acquired using spectral X-ray detectors allows noninvasive identification and characterization of chemical components of a material. To achieve this, it is important that the energy response of the detector is calibrated. The established techniques for energy calibration are not practical for routine use in pre-clinical or clinical research environment. This is due to the requirements of using monochromatic radiation sources such as synchrotron, radio-isotopes, and prohibitively long time needed to set up the equipment and make measurements. To address these limitations, we have developed an automated technique for calibrating the energy response of the pixels in a spectral X-ray detector that runs with minimal user intervention. This technique uses the X-ray tube voltage (kVp) as a reference energy, which is stepped through an energy range of interest. This technique locates the energy threshold where a pixel transitions from not-counting (off) to counting (on). Similarly, we have developed a technique for calibrating the energy response of individual pixels using X-ray fluorescence generated by metallic targets directly irradiated with polychromatic X-rays, and additionally γ-rays from (241)Am. This technique was used to measure the energy response of individual pixels in CdTe-Medipix3RX by characterizing noise performance, threshold dispersion, gain variation and spectral resolution. The comparison of these two techniques shows the energy difference of 1 keV at 59.5 keV which is less than the spectral resolution of the detector (full-width at half-maximum of 8 keV at 59.5 keV). Both techniques can be used as quality control tools in a pre-clinical multi-energy CT scanner using spectral X-ray detectors.

  19. A Focused, Hard X-ray Look at Arp 299 with NuSTAR

    CERN Document Server

    Ptak, A; Zezas, A; Lehmer, B; Yukita, M; Wik, D; Antoniou, V; Argo, M K; Ballo, L; Bechtol, K; Boggs, S; Della Ceca, R; Christensen, F E; Craig, W W; Hailey, C J; Harrison, F A; Krivonos, R; Maccarone, T J; Stern, D; Tatum, M; Venters, T; Zhang, W W

    2014-01-01

    We report on simultaneous observations of the local starburst system Arp 299 with NuSTAR and Chandra, which provides the first resolved images of this galaxy up to energies of ~ 45 keV. Fitting the 3-40 keV spectrum reveals a column density of $N_{\\rm H}$ ~ 4 x10^{24} cm^{-2}, characteristic of a Compton-thick AGN, and a 10-30 keV luminosity of 1.2x 10^{43} ergs s^{-1}. The hard X-rays detected by NuSTAR above 10 keV are centered on the western nucleus, Arp 299-B, which previous X-ray observations have shown to be the primary source of neutral Fe-K emission. Other X-ray sources, including Arp 299-A, the eastern nucleus which is also thought to harbor an AGN, as well as X-ray binaries, contribute $\\lesssim 10%$ to the 10-20 keV emission from the Arp 299 system. The lack of significant emission above 10 keV other than that attributed to Arp 299-B suggests that: a) any AGN in Arp 299-A must be heavily obscured ($N_{\\rm H}$ > 10^{24} cm^{-2}) or have a much lower luminosity than Arp 299-B and b) the extranuclear ...

  20. Small hard X-ray source using X-band linac

    CERN Document Server

    Uesaka, M; Iijima, H; Tsuchihashi, K; Urakawa, J; Higo, T; Akemoto, M; Hayano, H

    2002-01-01

    For application to dynamic angiographies and life science, small hard X-ray source by laser electron beam collision using X-band linac has been developed. The outline of X-band linac system and the X-ray intensity are discussed. The X-ray intensity of some combinations of laser and electron sources was evaluated by numerical calculations. Four kinds of combinations such as photo-cathode RF-gun + short pulse laser, thermionic-cathode RF-gun + Q-switch Nd:YAG laser, multi-bunch photo-cathode RF-gun + laser accumulator and 200 MeV electron storage ring + laser accumulator were investigated. X-band RF-gun is being used and S-band Mg photo-cathode RF-gun is studied. The X-ray intensity of the thermionic-cathode RF-gun + Q-switch Nd:YAG laser is 10 sup 7 phons/s(total) at 50 keV. This value can be used for structure analysis of protein. (S.Y.)

  1. Hard X-Ray Emission from Partially Occulted Solar Flares: RHESSI Observations in Two Solar Cycles

    Science.gov (United States)

    Effenberger, Frederic; Rubio da Costa, Fatima; Oka, Mitsuo; Saint-Hilaire, Pascal; Liu, Wei; Petrosian, Vahé; Glesener, Lindsay; Krucker, Säm

    2017-02-01

    Flares close to the solar limb, where the footpoints are occulted, can reveal the spectrum and structure of the coronal looptop source in X-rays. We aim at studying the properties of the corresponding energetic electrons near their acceleration site, without footpoint contamination. To this end, a statistical study of partially occulted flares observed with Reuven Ramaty High-Energy Solar Spectroscopic Imager is presented here, covering a large part of solar cycles 23 and 24. We perform detailed spectra, imaging, and light curve analyses for 116 flares and include contextual observations from SDO and STEREO when available, providing further insights into flare emission that were previously not accessible. We find that most spectra are fitted well with a thermal component plus a broken power-law, non-thermal component. A thin-target kappa distribution model gives satisfactory fits after the addition of a thermal component. X-ray imaging reveals small spatial separation between the thermal and non-thermal components, except for a few flares with a richer coronal source structure. A comprehensive light curve analysis shows a very good correlation between the derivative of the soft X-ray flux (from GOES) and the hard X-rays for a substantial number of flares, indicative of the Neupert effect. The results confirm that non-thermal particles are accelerated in the corona and estimated timescales support the validity of a thin-target scenario with similar magnitudes of thermal and non-thermal energy fluxes.

  2. Picosecond time-resolved laser pump/X-ray probe experiments using a gated single-photon-counting area detector

    DEFF Research Database (Denmark)

    Ejdrup, T.; Lemke, H.T.; Haldrup, Martin Kristoffer

    2009-01-01

    . The capability of the gated PILATUS detector to selectively detect the signal from a given X-ray pulse in 24 bunch mode at the APS storage ring is demonstrated. A test experiment performed on polycrystalline organic thin films of [alpha]-perylene illustrates the possibility of reaching an X-ray pulse duration......The recent developments in X-ray detectors have opened new possibilities in the area of time-resolved pump/probe X-ray experiments; this article presents the novel use of a PILATUS detector to achieve X-ray pulse duration limited time-resolution at the Advanced Photon Source (APS), USA...... limited time-resolution of 60 ps using the gated PILATUS detector. This is the first demonstration of X-ray pulse duration limited data recorded using an area detector without the use of a mechanical chopper array at the beamline....

  3. Bismuth Passivation Technique for High-Resolution X-Ray Detectors

    Science.gov (United States)

    Chervenak, James; Hess, Larry

    2013-01-01

    The Athena-plus team requires X-ray sensors with energy resolution of better than one part in 3,000 at 6 keV X-rays. While bismuth is an excellent material for high X-ray stopping power and low heat capacity (for large signal when an X-ray is stopped by the absorber), oxidation of the bismuth surface can lead to electron traps and other effects that degrade the energy resolution. Bismuth oxide reduction and nitride passivation techniques analogous to those used in indium passivation are being applied in a new technique. The technique will enable improved energy resolution and resistance to aging in bismuth-absorber-coupled X-ray sensors. Elemental bismuth is lithographically integrated into X-ray detector circuits. It encounters several steps where the Bi oxidizes. The technology discussed here will remove oxide from the surface of the Bi and replace it with nitridized surface. Removal of the native oxide and passivating to prevent the growth of the oxide will improve detector performance and insulate the detector against future degradation from oxide growth. Placing the Bi coated sensor in a vacuum system, a reduction chemistry in a plasma (nitrogen/hydrogen (N2/H2) + argon) is used to remove the oxide and promote nitridization of the cleaned Bi surface. Once passivated, the Bi will perform as a better X-ray thermalizer since energy will not be trapped in the bismuth oxides on the surface. A simple additional step, which can be added at various stages of the current fabrication process, can then be applied to encapsulate the Bi film. After plasma passivation, the Bi can be capped with a non-diffusive layer of metal or dielectric. A non-superconducting layer is required such as tungsten or tungsten nitride (WNx).

  4. On the use of CCD area detectors for high-resolution specular X-ray reflectivity.

    Science.gov (United States)

    Fenter, P; Catalano, J G; Park, C; Zhang, Z

    2006-07-01

    The use and application of charge coupled device (CCD) area detectors for high-resolution specular X-ray reflectivity is discussed. Direct comparison of high-resolution specular X-ray reflectivity data measured with CCD area detectors and traditional X-ray scintillator ('point') detectors demonstrates that the use of CCD detectors leads to a substantial (approximately 30-fold) reduction in data acquisition rates because of the elimination of the need to scan the sample to distinguish signal from background. The angular resolution with a CCD detector is also improved by a factor of approximately 3. The ability to probe the large dynamic range inherent to high-resolution X-ray reflectivity data in the specular reflection geometry was demonstrated with measurements of the orthoclase (001)- and alpha-Al2O3 (012)-water interfaces, with measured reflectivity signals varying by a factor of approximately 10(6) without the use of any beam attenuators. Statistical errors in the reflectivity signal are also derived and directly compared with the repeatability of the measurements.

  5. Towards hybrid pixel detectors for energy-dispersive or soft X-ray photon science.

    Science.gov (United States)

    Jungmann-Smith, J H; Bergamaschi, A; Brückner, M; Cartier, S; Dinapoli, R; Greiffenberg, D; Huthwelker, T; Maliakal, D; Mayilyan, D; Medjoubi, K; Mezza, D; Mozzanica, A; Ramilli, M; Ruder, Ch; Schädler, L; Schmitt, B; Shi, X; Tinti, G

    2016-03-01

    JUNGFRAU (adJUstiNg Gain detector FoR the Aramis User station) is a two-dimensional hybrid pixel detector for photon science applications at free-electron lasers and synchrotron light sources. The JUNGFRAU 0.4 prototype presented here is specifically geared towards low-noise performance and hence soft X-ray detection. The design, geometry and readout architecture of JUNGFRAU 0.4 correspond to those of other JUNGFRAU pixel detectors, which are charge-integrating detectors with 75 µm × 75 µm pixels. Main characteristics of JUNGFRAU 0.4 are its fixed gain and r.m.s. noise of as low as 27 e(-) electronic noise charge (X-ray irradiation from an X-ray tube and a synchrotron light source are successfully demonstrated with an r.m.s. energy resolution of 20% (no mask) and 14% (with the mask) at 1.2 keV and of 5% at 13.3 keV. The performance evaluation of the JUNGFRAU 0.4 prototype suggests that this detection system could be the starting point for a future detector development effort for either applications in the soft X-ray energy regime or for an energy-dispersive detection system.

  6. Large area high-resolution CCD-based X-ray detector for macromolecular crystallography

    CERN Document Server

    Pokric, M; Jorden, A R; Cox, M P; Marshall, A; Long, P G; Moon, K; Jerram, P A; Pool, P; Nave, C; Derbyshire, G E; Helliwell, J R

    2002-01-01

    An X-ray detector system for macromolecular crystallography based on a large area charge-coupled device (CCD) sensor has been developed as part of a large research and development programme for advanced X-ray sensor technology, funded by industry and the Particle Physics and Astronomy Research Council (PPARC) in the UK. The prototype detector consists of two large area three-sides buttable charge-coupled devices (CCD 46-62 EEV), where the single CCD area is 55.3 mmx41.5 mm. Overall detector imaging area is easily extendable to 85 mmx110 mm. The detector consists of an optically coupled X-ray sensitive phosphor, skewed fibre-optic studs and CCDs. The crystallographic measurement requirements at synchrotron sources are met through a high spatial resolution (2048x1536 pixel array), high dynamic range (approx 10 sup 5), a fast readout (approx 1 s), low noise (<10e sup -) and much reduced parallax error. Additionally, the prototype detector system has been optimised by increasing its efficiency at low X-ray ene...

  7. Generalised Cornu spirals: an experimental study using hard x-rays.

    Science.gov (United States)

    Werdiger, Freda; Kitchen, Marcus J; Paganin, David M

    2016-05-16

    The Cornu spiral is a graphical aid that has been used historically to evaluate Fresnel integrals. It is also the Argand-plane mapping of a monochromatic complex scalar plane wave diffracted by a hard edge. We have successfully reconstructed a Cornu spiral due to diffraction of hard x-rays from a piece of Kapton tape. Additionally, we have explored the generalisation of the Cornu spiral by observing the Argand-plane mapping of complex scalar electromagnetic fields diffracted by a cylinder and a sphere embedded within a cylinder.

  8. An InGrid based Low Energy X-ray Detector

    CERN Document Server

    Krieger, Christoph; Kaminski, Jochen; Lupberger, Michael; Vafeiadis, Theodoros

    2014-01-01

    An X-ray detector based on the combination of an integrated Micromegas stage with a pixel chip has been built in order to be installed at the CERN Axion Solar Telescope. Due to its high granularity and spatial resolution this detector allows for a topological background suppression along with a detection threshold below $1\\,\\text{keV}$. Tests at the CAST Detector Lab show the detector's ability to detect X-ray photons down to an energy as low as $277\\,\\text{eV}$. The first background data taken after the installation at the CAST experiment underline the detector's performance with an average background rate of $5\\times10^{-5}\\,/\\text{keV}/\\text{cm}^2/\\text{s}$ between 2 and $10\\,\\text{keV}$ when using a lead shielding.

  9. Investigation of GEM-Micromegas Detector on X-ray Beam of Synchrotron Radiation

    CERN Document Server

    Zhang, YuLian; Hu, BiTao; Fan, ShengNan; Wang, Bo; Liu, Mei; Zhang, Jian; Liu, RongGuang; Chang, GuangCai; Liu, Peng; Ouyang, Qun; Chen, YuanBo; Yi, FuTing

    2013-01-01

    To solve the discharge of the standard Bulk Micromegas and GEM detector, the GEM-Micromegas detector was developed in Institute of High Energy Physics. Taking into account the advantages of the two detectors, one GEM foil was set as a preamplifier on the mesh of Micromegas in the structure and the GEM preamplification decreased the working voltage of Micromegas to reduce the effect of the discharge significantly. In the paper, the performance of detector in X-ray beam was studied at 1W2B laboratory of Beijing Synchrotron Radiation Facility. Finally, the result of the energy resolution under various X-ray energies was given in different working gases. It indicated that the GEM-Micromegas detector had the energy response capability in all the energy range and it could work better than the standard Bulk-Micromegas.

  10. A new solid-conversion gas detector for high energy X-ray industrial computed tomography

    Institute of Scientific and Technical Information of China (English)

    ZHOU Ri-feng; CHEN Wei-min; DUAN Xiao-jiao

    2011-01-01

    A new type of solid-conversion gas detector is investigated for high energy X-ray industrial computed tomography(H ECT).The conversion efficiency is calculated by using the EGSnrc Monte Carlo code on the Linux platform to simulate the transport process of photons and electrons in the detector.The simulation results show that the conversion efficiency could be more than 65%,if the X-ray beam width is less than about 0.2 mm,and a tungsten slab with 0.2 mum thickness and 30 mm length is employed as a radiation conversion medium.Meanwhile the results indicate that this new detector has higher conversion efficiency as well as less volume.Theoretically this new kind of detector could take place of the traditional scintillation detector for HECT.

  11. X-ray micro-beam characterization of a small pixel spectroscopic CdTe detector

    Science.gov (United States)

    Veale, M. C.; Bell, S. J.; Seller, P.; Wilson, M. D.; Kachkanov, V.

    2012-07-01

    A small pixel, spectroscopic, CdTe detector has been developed at the Rutherford Appleton Laboratory (RAL) for X-ray imaging applications. The detector consists of 80 × 80 pixels on a 250 μm pitch with 50 μm inter-pixel spacing. Measurements with an 241Am γ-source demonstrated that 96% of all pixels have a FWHM of better than 1 keV while the majority of the remaining pixels have FWHM of less than 4 keV. Using the Diamond Light Source synchrotron, a 10 μm collimated beam of monochromatic 20 keV X-rays has been used to map the spatial variation in the detector response and the effects of charge sharing corrections on detector efficiency and resolution. The mapping measurements revealed the presence of inclusions in the detector and quantified their effect on the spectroscopic resolution of pixels.

  12. An X-ray scanner prototype based on a novel hybrid gaseous detector

    CERN Document Server

    Iacobaeus, C; Lund-Jensen, B; Peskov, Vladimir

    2007-01-01

    We have developed a prototype of a new type of hybrid X-ray detector. It contains a thin wall (few μm) edge- illuminated lead glass capillary plate (acting as a converter of X-rays photons to primary electrons) combined with a microgap parallel-plate avalanche chamber operating in various gas mixtures at 1 atm. The operation of these converters was studied in a wide range of X-ray energies (from 6 to 60 keV) at incident angles varying from 0° to 90°. The detection efficiency, depending on the geometry, photon's energy, incident angle and the mode of operation, was between a few and 40%. The position resolution achieved was 50 μm in digital form and was practically independent of the photon's energy or gas mixture. The developed detector may open new possibilities for medical imaging, for example in mammography, portal imaging, radiography (including security devices), crystallography and many other applications.

  13. Fundamental x-ray interaction limits in diagnostic imaging detectors: frequency-dependent Swank noise.

    Science.gov (United States)

    Hajdok, G; Battista, J J; Cunningham, I A

    2008-07-01

    A frequency-dependent x-ray Swank factor based on the "x-ray interaction" modulation transfer function and normalized noise power spectrum is determined from a Monte Carlo analysis. This factor was calculated in four converter materials: amorphous silicon (a-Si), amorphous selenium (a-Se), cesium iodide (CsI), and lead iodide (PbI2) for incident photon energies between 10 and 150 keV and various converter thicknesses. When scaled by the quantum efficiency, the x-ray Swank factor describes the best possible detective quantum efficiency (DQE) a detector can have. As such, this x-ray interaction DQE provides a target performance benchmark. It is expressed as a function of (Fourier-based) spatial frequency and takes into consideration signal and noise correlations introduced by reabsorption of Compton scatter and photoelectric characteristic emissions. It is shown that the x-ray Swank factor is largely insensitive to converter thickness for quantum efficiency values greater than 0.5. Thus, while most of the tabulated values correspond to thick converters with a quantum efficiency of 0.99, they are appropriate to use for many detectors in current use. A simple expression for the x-ray interaction DQE of digital detectors (including noise aliasing) is derived in terms of the quantum efficiency, x-ray Swank factor, detector element size, and fill factor. Good agreement is shown with DQE curves published by other investigators for each converter material, and the conditions required to achieve this ideal performance are discussed. For high-resolution imaging applications, the x-ray Swank factor indicates: (i) a-Si should only be used at low-energy (e.g., mammography); (ii) a-Se has the most promise for any application below 100 keV; and (iii) while quantum efficiency may be increased at energies just above the K edge in CsI and PbI2, this benefit is offset by a substantial drop in the x-ray Swank factor, particularly at high spatial frequencies.

  14. Analysis of the charge collection process in solid state X-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Kimmel, Nils

    2009-02-12

    Physics with X-rays spans from observing large scales in X-ray astronomy down to small scales in material structure analyses with synchrotron radiation. Both fields of research require imaging detectors featuring spectroscopic resolution for X-rays in an energy range of 0.1 keV to 20.0 keV. Originally driven by the need for an imaging spectrometer on ESA's X-ray astronomy satellite mission XMM-Newton, X-ray pnCCDs were developed at the semiconductor laboratory of the Max-Planck-Institute. The pnCCD is a pixel array detector made of silicon. It is sensitive over a wide band from near infrared- over optical- and UV-radiation up to X-rays. This thesis describes the dynamics of signal electrons from the moment after their generation until their collection in the potential minima of the pixel structure. Experimentally, a pinhole array was used to scan the pnCCD surface with high spatial resolution. Numerical simulations were used as a tool for the modeling of the electrical conditions inside the pnCCD. The results predicted by the simulations were compared with the measurements. Both, experiment and simulation, helped to establish a model for the signal charge dynamics in the energy range from 0.7 keV to 5.5 keV. More generally, the presented work has enhanced the understanding of the detector system on the basis of a physical model. The developed experimental and theoretical methods can be applied to any type of array detector which is based on the full depletion of a semiconductor substrate material. (orig.)

  15. A Hard X-Ray Study of the Normal Star-Forming Galaxy M83 with NuSTAR

    DEFF Research Database (Denmark)

    Yukita, M.; Hornschemeier, A. E.; Lehmer, B. D.

    2016-01-01

    likely dominated by intermediate accretion state black hole binaries and neutron star low-mass X-ray binaries (Z-sources). We construct the X-ray binary luminosity function (XLF) in the NuSTAR band for an extragalactic environment for the first time. The M83 XLF has a steeper XLF than the X-ray binary......We present the results from sensitive, multi-epoch NuSTAR observations of the late-type star-forming galaxy M83 (d = 4.6 Mpc). This is the first investigation to spatially resolve the hard (E > 10 keV) X-ray emission of this galaxy. The nuclear region and similar to 20 off-nuclear point sources......, including a previously discovered ultraluminous X-ray source, are detected in our NuSTAR observations. The X-ray hardnesses and luminosities of the majority of the point sources are consistent with hard X-ray sources resolved in the starburst galaxy NGC 253. We infer that the hard X-ray emission is most...

  16. Accretion flow diagnostics with X-ray spectral timing: the hard state of SWIFT J1753.5-0127

    NARCIS (Netherlands)

    Cassatella, P.; Uttley, P.; Maccarone, T.

    2012-01-01

    Recent XMM-Newton studies of X-ray variability in the hard states of black hole X-ray binaries (BHXRBs) indicate that the variability is generated in the ‘standard’ optically thick accretion disc that is responsible for the multi-colour blackbody emission. The variability originates in the disc as

  17. [O III]$\\lambda 5007$ and X-ray Properties of a Complete Sample of Hard X-ray Selected AGNs in the Local Universe

    CERN Document Server

    Ueda, Y; Ichikawa, K; Ishino, Y; Kniazev, A Y; Vaisanen, P; Ricci, C; Berney, S; Gandhi, P; Koss, M; Mushotzky, R; Terashima, Y; Trakhtenbrot, B; Crenshaw, M

    2015-01-01

    We study the correlation between the [O III]$\\lambda 5007$ and X-ray luminosities of local Active Galactic Nuclei (AGNs), using a complete, hard X-ray ($>10$ keV) selected sample in the Swift/BAT 9-month catalog. From our optical spectroscopic observations at the South African Astronomical Observatory and the literature, a catalog of [O III]$\\lambda 5007$ line flux for all 103 AGNs at Galactic latitudes of $|b|>15^\\circ$ is complied. Significant correlations with intrinsic X-ray luminosity ($L_{\\rm X}$) are found both for observed ($L_{\\rm [O~III]}$) and extinction-corrected ($L_{\\rm [O~III]}^{\\rm cor}$) luminosities, separately for X-ray unabsorbed and absorbed AGNs. We obtain the regression form of $L_{\\rm [O~III]}$ $\\propto L_{\\rm 2-10\\; keV}^{1.18\\pm0.07}$ and $L_{\\rm [O~III]}^{\\rm cor}$ $\\propto L_{\\rm 2-10\\; keV}^{1.16\\pm0.09}$ from the whole sample. The absorbed AGNs with low ($<$0.5\\%) scattering fractions in soft X-rays show on average smaller $L_{\\rm [O~III]}/L_{\\rm X}$ and $L_{\\rm [O~III]}^{\\rm ...

  18. Femtosecond time-resolved X-ray absorption spectroscopy of liquid using a hard X-ray free electron laser in a dual-beam dispersive detection method.

    Science.gov (United States)

    Obara, Yuki; Katayama, Tetsuo; Ogi, Yoshihiro; Suzuki, Takayuki; Kurahashi, Naoya; Karashima, Shutaro; Chiba, Yuhei; Isokawa, Yusuke; Togashi, Tadashi; Inubushi, Yuichi; Yabashi, Makina; Suzuki, Toshinori; Misawa, Kazuhiko

    2014-01-13

    We present femtosecond time-resolved X-ray absorption spectroscopy of aqueous solution using a hard x-ray free electron laser (SACLA) and a synchronized Ti:sapphire laser. The instrumental response time is 200 fs, and the repetition rate of measurement is 10 Hz. A cylindrical liquid beam 100 μm in diameter of aqueous ammonium iron(III) oxalate solution is photoexcited at 400 nm, and the transient X-ray absorption spectra are measured in the K-edge region of iron, 7.10 - 7.26 keV, using a dual X-ray beam dispersive detection method. Each of the dual beams has the pulse energy of 1.4 μJ, and pump-induced absorbance change on the order of 10(-3) is successfully detected. The photoexcited iron complex exhibits a red shifted iron K-edge with the appearance time constant of 260 fs. The X-ray absorption difference spectra, with and without the pump pulses, are independent of time delay after 1.5 ps up to 100 ps, indicating that the photoexcited species is long-lived.

  19. Gamma-ray emitting radio galaxies at hard X-rays: Seyfert core or jet emission?

    CERN Document Server

    Beckmann, V; Mattana, F; Saez, D; Soldi, S

    2013-01-01

    A number of radio galaxies has been detected by Fermi/LAT in the gamma-ray domain. In some cases, like Cen A and M 87, these objects have been seen even in the TeV range by Cherenkov telescopes. Whereas the gamma-ray emission is likely to be connected with the non-thermal jet emission, dominating also the radio band, the situation is less clear at hard X-rays. While the smoothly curved continuum emission and the overall spectral energy distribution indicate a non-thermal emission, other features such as the iron line emission and the low variability appear to be rather of Seyfert type, i.e. created in the accretion disk and corona around the central black hole. We investigate several prominent cases using combined X-ray and gamma-ray data in order to constrain the possible contributions of the jet and the accretion disk to the overall spectral energy distribution in radio galaxies. Among the three sources we study, three different origins of the hard X-ray flux can be identified. The emission can be purely no...

  20. Hard X-ray Spectrum of Mkn 421 during the Active Phase

    Indian Academy of Sciences (India)

    R. K. Manchanda

    2001-06-01

    Spectral measurement of Mkn 421 were made in the hard X-ray energy band of 20–200 keV using a high sensitivity, large area scintillation counter telescope on November 21, 2000 and these coincided with the onset of an active X-ray phase as seen in the ASM counting rates on board RXTE. The observed spectrum can not be fitted to a single power law similar to the PDS data of BeppoSAX. The data can be fitted both by a two component power-law function or a combination of an exponential function with a power law component at the high energies above 80 keV. We identify these components with those arising from the synchrotron self compton and the high energy power-law tail arising from the upgrading of the thermal photons due to multiple Compton scattering a la Cyg X-1. A comparison with the earlier data clearly suggests a spectral variability in the hard X-ray spectrum of the source. We propose a continuously flaring geometry for the source as the underlying mechanism for energy release.