WorldWideScience

Sample records for hard chromium plating

  1. Electrospark Deposition for Depot- and Field-Level Component Repair and Replacement of Hard Chromium Plating

    Science.gov (United States)

    2006-09-07

    grooves. The process was characterized for deposition rate and coating quality – hardness, porosity and discontinuities. The following data were...the Battelle Pacific Northwest National Laboratories (PNNL), formerly Westinghouse Hanford Company, in Richland, Washington, and Washington State... 300 400 500 Manual Automated No UIT Automated with UIT Substrate M ic ro ha rd ne ss (K no op ) Figure 3-20 Hardness Versus Application Procedure

  2. Electrospark Deposition for Depot- and Field-Level Component Repair and Replacement of Hard Chromium Plating

    Science.gov (United States)

    2008-02-01

    surfaces. Commonly used electrodes for wear and friction enhancement include sintered carbides, borides , and hard alloys such as Stellite 1, Stellite 6...Tribaloy 700 and 800, and molybdenum . The dynamic coefficient of friction of machine component surfaces can be reduced from 0.6 to less than 0.2

  3. 77 FR 58219 - National Emission Standards for Hazardous Air Pollutant Emissions: Hard and Decorative Chromium...

    Science.gov (United States)

    2012-09-19

    ... Hazardous Air Pollutant Emissions: Hard and Decorative Chromium Electroplating and Chromium Anodizing Tanks... Pollutant Emissions: Hard and Decorative Chromium Electroplating and Chromium Anodizing Tanks; and Steel... air pollutants (NESHAP): hard and decorative chromium electroplating and chromium anodizing tanks, and...

  4. Laboratory Automatic Titration of Chromium Plating and Electropolishing Solutions

    National Research Council Canada - National Science Library

    Sopok, Samuel

    2001-01-01

    .... The analytical chemistry literature lacks an adequate automatic titration method for the monitoring of chromic acid in chromium plating solutions and the monitoring of phosphoric and sulfuric acids...

  5. Determination of Wastewater Acids from Chromium Plating and Electropolishing Solutions

    National Research Council Canada - National Science Library

    Sopok, Samuel

    1995-01-01

    ... Laboratories vessel plating program. The chemical literature provides offline laboratory detection of chromic acid from chromium plating wastewater solutions, as well as phosphoric and sulfuric acids from electropolishing wastewater solutions...

  6. Utilization of Ion Chromatography and Statistics to Determine Important Acids in Chromium Plating and Electropolishing Solutions

    National Research Council Canada - National Science Library

    Sopok, Samuel

    1991-01-01

    Inadequate monitoring of sulfuric and chromic acids in chromium plating solutions and phosphoric and sulfluric acids in electropolishing solutions can cause serious problems for the chromium plating...

  7. Influence of Hardness on Perforation Velocity in Steel Armour Plates

    OpenAIRE

    S. N. Dikshit

    2000-01-01

    In an earlier investigation3, the influence ofh'ardness on tempered steel armour plates of 20 mm thickness, impacted by. 20 mm diameter steel ogive-shaped projectile at normal , was studied. Additional data is investigated with relation to the perforation velocity of the plates. It is observed that the plate perforation velocity and the plate plugging velocity decrease with increasing plate hardness.

  8. Chromium nitride-silver self-lubricating nanoporous hard coatings

    Science.gov (United States)

    Mulligan Christopher P

    The focus of this thesis research is to explore a new approach to adaptive solid lubrication using nanoporous hard coatings. To investigate this approach, I deposited prototype coatings for study consisting of a hard chromium nitride (CrN) matrix co-deposited with a lubricious silver (Ag) phase by reactive magnetron co-sputtering. The idea is to exploit the relative immiscibility of the two phases to create nanocomposite structures with intrinsic lubricant transport properties enabled by the presence of the nanopores. Specifically, I develop the scientific understanding of the critical growth parameters that govern nanocomposite structural evolution which in turn control mechanical properties, solid lubricant diffusion, and tribological response. Mechanical properties were analyzed by both micro and nanoindentation measurements for the composites as a function of Ag aggregate morphology. For Ts ≤ 500°C, hardness as measured by nanoindentation into the surface is relatively uniform giving values of 14.6, 13.6, and 14.3 GPa for Ts = 300, 400, and 500°C respectively. For Ts > 500°C, the cross-sectional microhardness increases with T s from 16.5 to 19.7 to 24.3 GPa for Ts = 500, 600, and 700°C, respectively, which is attributed to a decrease in the effective Ag concentration associated with temperature activated segregation. The average hardness for pure CrN samples is 23.8 and 27.5 GPa as measured by surface nanoindentation and cross-sectional microindentation, respectively. Lubricant transport behavior was characterized by a series of vacuum annealing experiments. Vacuum annealing experiments at Ta = 425, 525, and 625°C show that Ag diffuses to the coating surface to form lubricious surface aggregates and that the rate for Ag lubricant transport increases with increasing DeltaT (Ta - Ts) for Ta > Ts, as determined by quantitative electron microscopy surface analyses. However, the Ag remains in the CrN matrix for Ta self-lubricating properties and tribological

  9. Nanocrystalline hard chromium electrodeposition from trivalent chromium bath containing carbamide and formic acid: Structure, composition, electrochemical corrosion behavior, hardness and wear characteristics of deposits

    Science.gov (United States)

    Danilov, F. I.; Protsenko, V. S.; Gordiienko, V. O.; Kwon, S. C.; Lee, J. Y.; Kim, M.

    2011-07-01

    The paper is devoted to the structure, composition and properties investigations of coatings obtained from a sulfate trivalent chromium bath containing formic acid and carbamide as the complexing agents. The results indicate that the deposits have a nanocrystalline type of structure-there are regions with atomic ordered arrangement in bulk material with the average size of 3-5 nm. Carbon is present as chromium carbide within the coating and it is distributed uniformly inside of the deposit. The deposits under study exhibit particular electrochemical behavior (absence of the active dissolution range in acid solution). The hardness of these coatings does not differ noticeably from that typical of coatings obtained in Cr(VI)-based baths. The wear characteristics of the deposits from the proposed bath are somewhat better than in the case of a common hexavalent chromium bath.

  10. Hard X-ray Zone Plates Using Ultrananocrystalline Diamond Molds

    Science.gov (United States)

    Wojcik, M. J.; Joshi, V.; Sumant, A. V.; Divan, R.; Ocola, L. E.; Lu, M.; Mancini, D. C.

    2011-09-01

    While hard x-ray zone plates have made great advances recently towards improved resolution, their focusing efficiency requires further development. This problem becomes more important as higher-energy x-rays are used for x-ray microscopy. The current method for fabricating zone plates involves a dielectric mold, which is then electroplated into, but the materials used for this mold are not mechanically stiff enough for the zone plates desired. Ultrananocrystalline diamond (UNCD) is a form of diamond that can be grown as a thin film by chemical vapor deposition and offers many of the physical properties of bulk diamond. Its mechanical stiffness, resistance to radiation damage, dielectric properties, and ability to be etched suggests UNCD as a capable mold material. Reported is progress in the fabrication of hard x-ray zone plates with gold electroformed into a UNCD mold.

  11. Fabrication of high-aspect-ratio hard x-ray zone plates with HSQ plating molds

    Science.gov (United States)

    Lu, Ming; Ocola, Leonidas E.; Divan, Ralu; Mancini, Derrick C.

    2008-08-01

    Fresnel zone plates are important x-ray diffractive optics which offer a focusing resolution approaching the theoretical limit. In hard x-ray region, the refractive indices of all the materials are close to unity, which requests thick zone plate to achieve a reasonable efficiency. It makes high-resolution zone plate extremely difficult to fabricate due to its high aspect ratio. We report a LIGA-like fabrication process employing e-beam resist HSQ as the plating mold material, which is relative simply compared with traditional processes. 1-μm-thick gold zone plates with 80-nm-wide outermost zone have been fabricated with this process.

  12. Hard X-ray imaging with microchannel plate optics

    CERN Document Server

    Price, G J; Fraser, G W; Bavdaz, M; Beijersbergen, M W; Boutot, J P; Fairbend, R; Flyckt, S O; Peacock, A; Tomaselli, E

    2002-01-01

    Square pore microchannel plates, with large channel aspect ratios, have been developed as part of an ESA technology research programme into efficient focusing at hard (>10 keV) X-ray energies. A planar MCP has been used to focus 50-65 keV X-rays for the first time.

  13. Online Automatic Titration of Chromic Acid in Chromium Plating Solutions and Phosphoric and Sulfuric Acids in Electropolishing Solutions

    National Research Council Canada - National Science Library

    Sopok, Samuel

    1991-01-01

    .... The analytical chemistry literature lacks an adequate online automatic titration method for the monitoring of chromic acid in chromium plating solutions and the monitoring of phosphoric and sulfuric...

  14. Development of a brazing process for the production of water- cooled bipolar plates made of chromium-coated metal foils for PEM fuel cells

    Science.gov (United States)

    Mueller, M.; Hoehlich, D.; Scharf, I.; Lampke, T.; Hollaender, U.; Maier, H. J.

    2016-03-01

    Beside lithium batteries, PEM fuel cells are the most promising strategy as a power source to achieve the targets for introducing and increasing the usage of electric vehicles. Due to limited space and weight problems, water cooled, metallic bipolar plates in a fuel cell metal stack are preferred in motor vehicles. These plates are stamped metal sheets with a complex structure, interconnected media-tight. To meet the multiple tasks and requirements in use, complex and expensive combinations of materials are currently in use (carbon fiber composites, graphite, gold-plated nickel, stainless and acid resistant steel). The production of such plates is expensive as it is connected with considerable effort or the usage of precious metals. As an alternative, metalloid nitrides (CrN, VN, W2N, etc.) show a high chemical resistance, hardness and a good conductivity. So this material category meets the basic requirements of a top layer. However, the standard methods for their production (PVD, CVD) are expensive and have a slow deposition rate and a lower layer thicknesses. Because of these limitations, a full functionality over the life cycle of a bipolar plate is not guaranteed. The contribution shows the development and quantification of an alternative production process for bipolar plates. The expectation is to get significant advantages from the combination of chromium electrodeposition and thermochemical treatment to form chromium nitrides. Both processes are well researched and suitable for series production. The thermochemical treatment of the chromium layer also enables a process-integrated brazing.

  15. Analyzing of Nonuniform Hardness for Anchorage Clamp Plate after Heat Treatment

    Science.gov (United States)

    Liu, Zhenmin; Wang, Lijun; Ruan, Shipeng; Wang, Ningtao

    2017-09-01

    20CrMnTi wire rod can be used to manufacture the anchorage clamp plate. In the normal production, the test results show that the hardness of anchorage clamp plate is nonuniform. In this paper, the chemical composition, microstructure, grain size of clamp plate billet and the microstructure, hardness of the finished clamp plate product were studied and analyzed. The results show that improper heat treatment technics causes nonuniform hardness for anchorage clamp plate.

  16. Hard-X-ray Zone Plates: Recent Progress

    Directory of Open Access Journals (Sweden)

    Syue-Ren Wu

    2012-09-01

    Full Text Available The technology to focus hard-X-rays (photon energy larger than 1–2 keV has made great progress in the past three years. The progress was particularly spectacular for lenses based on the Fresnel zone plate concept. The spatial resolution notably increased by a factor of three, opening up entirely new domains of application, specifically in biomedical research. As we shall see, this evolution is the result of a painstaking optimization of many different aspects rather than of a single technical breakthrough.

  17. Improved adhesion of ultra-hard carbon films on cobalt–chromium orthopaedic implant alloy

    Science.gov (United States)

    Vaid, Rishi; Diggins, Patrick; Weimer, Jeffrey J.; Koopman, M.; Vohra, Yogesh K.

    2010-01-01

    While interfacial graphite formation and subsequent poor film adhesion is commonly reported for chemical vapor deposited hard carbon films on cobalt-based materials, we find the presence of O2 in the feedgas mixture to be useful in achieving adhesion on a CoCrMo alloy. Nucleation studies of surface structure before formation of fully coalesced hard carbon films reveal that O2 feedgas helps mask the catalytic effect of cobalt with carbon through early formation of chromium oxides and carbides. The chromium oxides, in particular, act as a diffusion barrier to cobalt, minimizing its migration to the surface where it would otherwise interact deleteriously with carbon to form graphite. When O2 is not used, graphitic soot forms and films delaminate readily upon cooling to room temperature. Continuous 1 μm-thick nanostructured carbon films grown with O2 remain adhered with measured hardness of 60 GPa and show stable, non-catastrophic circumferential micro-cracks near the edges of indent craters made using Rockwell indentation. PMID:21221739

  18. Improved adhesion of ultra-hard carbon films on cobalt-chromium orthopaedic implant alloy.

    Science.gov (United States)

    Catledge, Shane A; Vaid, Rishi; Diggins, Patrick; Weimer, Jeffrey J; Koopman, Mark; Vohra, Yogesh K

    2011-02-01

    While interfacial graphite formation and subsequent poor film adhesion is commonly reported for chemical vapor deposited hard carbon films on cobalt-based materials, we find the presence of O(2) in the feedgas mixture to be useful in achieving adhesion on a CoCrMo alloy. Nucleation studies of surface structure before formation of fully coalesced hard carbon films reveal that O(2) feedgas helps mask the catalytic effect of cobalt with carbon through early formation of chromium oxides and carbides. The chromium oxides, in particular, act as a diffusion barrier to cobalt, minimizing its migration to the surface where it would otherwise interact deleteriously with carbon to form graphite. When O(2) is not used, graphitic soot forms and films delaminate readily upon cooling to room temperature. Continuous 1 μm-thick nanostructured carbon films grown with O(2) remain adhered with measured hardness of 60 GPa and show stable, non-catastrophic circumferential micro-cracks near the edges of indent craters made using Rockwell indentation.

  19. Casting of Hearth Plates from High-chromium Steel

    Directory of Open Access Journals (Sweden)

    Drotlew A.

    2014-12-01

    Full Text Available The paper presents the results of studies on the development of manufacturing technologies to cast hearth plates operating in chamber furnaces for heat treatment. Castings made from the heat-resistant G-X40CrNiSi27-4 steel were poured in hand-made green sand molds. The following operations were performed: computer simulation to predict the distribution of internal defects in castings produced by the above mentioned technology with risers bare and coated with exothermic and insulating sleeves, analysis of each variant of the technology, and manufacture of experimental castings. As a result of the conducted studies and analysis it was found that the use of risers with exothermic sleeves does not affect to a significant degree the quality of the produced castings of hearth plates, but it significantly improves the metal yield.

  20. Chromium

    Science.gov (United States)

    ... intravenously showed signs of diabetes (including weight loss, neuropathy, and impaired glucose tolerance) until chromium was added to their feeding solution. The chromium, added at doses of 150 to 250 mcg/day for up to two weeks, corrected their diabetes ...

  1. Zone Plates for Hard X-Ray FEL Radiation

    Science.gov (United States)

    Nilsson, D.; Holmberg, A.; Sinn, H.; Vogt, U.

    2011-09-01

    We investigated theoretically the use of zone plates for the focusing of the European X-ray Free Electron Laser (XFEL). In a finite-element simulation the heat load on zone plates placed in the high intensity x-ray beam was simulated for four different zone plate materials: gold, iridium, tungsten, and CVD diamond. The main result of the calculations is that all zone plates remain below the melting temperature throughout a full XFEL pulse train of 3000 pulses. However, if the zone plate is placed in the direct beam it will experience large and rapid temperature fluctuations on the order of 300 K. The situation is relaxed if the optic is placed behind a monochromator and the fluctuations are reduced to around 20 K. Besides heat load, the maximization of the total efficiency of the complete optical system is an important issue. We calculated the efficiency of different zone plates and monochromator systems and found that the final beam size of the XFEL in combination with its monochromaticity will be important parameters.

  2. Standard specification for Nickel-Chromium-Iron alloys (UNS N06600, N06601, N06603, N06690, N06693, N06025, N06045 and N06696), Nickel-Chromium-Cobalt-Molybdenum alloy (UNS N06617), and Nickel-Iron-Chromium-Tungsten alloy (UNS N06674) plate, sheet and strip

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    Standard specification for Nickel-Chromium-Iron alloys (UNS N06600, N06601, N06603, N06690, N06693, N06025, N06045 and N06696), Nickel-Chromium-Cobalt-Molybdenum alloy (UNS N06617), and Nickel-Iron-Chromium-Tungsten alloy (UNS N06674) plate, sheet and strip

  3. Demixing in a hard rod-plate mixture

    NARCIS (Netherlands)

    Roij, R. van; Mulder, B.

    1994-01-01

    We argue that the possibility to observe a stable biaxial nematic phase in a binary mixture of prolate and oblate hard particles is seriously limited by the existence of entropydriven demixing. This result follows from a simple Onsager-type density functional theory. An important feature15 the

  4. CAPSULE REPORT: HARD CHROME FUME SUPPRESSANTS & CONTROL TECHNOLOGIES

    Science.gov (United States)

    All existing information which includes the information extrapolated from the Hard Chrome Pollution Prevention Demonstration Project(s) and other sources derived from plating facilities and industry contacts, will be condensed and featured in this document. At least five chromium...

  5. Mechanical design of multiple zone plates precision alignment apparatus for hard X-ray focusing in twenty-nanometer scale

    Science.gov (United States)

    Shu, Deming; Liu, Jie; Gleber, Sophie C.; Vila-Comamala, Joan; Lai, Barry; Maser, Jorg M.; Roehrig, Christian; Wojcik, Michael J.; Vogt, Franz Stefan

    2017-04-04

    An enhanced mechanical design of multiple zone plates precision alignment apparatus for hard x-ray focusing in a twenty-nanometer scale is provided. The precision alignment apparatus includes a zone plate alignment base frame; a plurality of zone plates; and a plurality of zone plate holders, each said zone plate holder for mounting and aligning a respective zone plate for hard x-ray focusing. At least one respective positioning stage drives and positions each respective zone plate holder. Each respective positioning stage is mounted on the zone plate alignment base frame. A respective linkage component connects each respective positioning stage and the respective zone plate holder. The zone plate alignment base frame, each zone plate holder and each linkage component is formed of a selected material for providing thermal expansion stability and positioning stability for the precision alignment apparatus.

  6. Determination of hexavalent chromium in exhaled breath condensate and environmental air among chrome plating workers

    Energy Technology Data Exchange (ETDEWEB)

    Goldoni, Matteo [Laboratory of Industrial Toxicology, Department of Clinical Medicine, Nephrology and Health Sciences, University of Parma, Via Gramsci 14, 43100 Parma (Italy); National Institute of Occupational Safety and Prevention, Research Centre at University of Parma, Parma (Italy); Caglieri, Andrea [Laboratory of Industrial Toxicology, Department of Clinical Medicine, Nephrology and Health Sciences, University of Parma, Via Gramsci 14, 43100 Parma (Italy); Poli, Diana [Laboratory of Industrial Toxicology, Department of Clinical Medicine, Nephrology and Health Sciences, University of Parma, Via Gramsci 14, 43100 Parma (Italy); National Institute of Occupational Safety and Prevention, Research Centre at University of Parma, Parma (Italy); Vettori, Maria Vittoria [Laboratory of Industrial Toxicology, Department of Clinical Medicine, Nephrology and Health Sciences, University of Parma, Via Gramsci 14, 43100 Parma (Italy); National Institute of Occupational Safety and Prevention, Research Centre at University of Parma, Parma (Italy); Corradi, Massimo [Laboratory of Industrial Toxicology, Department of Clinical Medicine, Nephrology and Health Sciences, University of Parma, Via Gramsci 14, 43100 Parma (Italy); National Institute of Occupational Safety and Prevention, Research Centre at University of Parma, Parma (Italy); Apostoli, Pietro [Laboratory of Industrial Hygiene, Department of Experimental and Applied Medicine, University of Brescia (Italy); Mutti, Antonio [Laboratory of Industrial Toxicology, Department of Clinical Medicine, Nephrology and Health Sciences, University of Parma, Via Gramsci 14, 43100 Parma (Italy)]. E-mail: antonio.mutti@unipr.it

    2006-03-15

    Chromium speciation has attracted attention because of the different toxicity of Cr(III), which is considered relatively non-toxic, and Cr(VI), which can cross cell membranes mainly as a chromate anion and has been classified as a class I human carcinogen. The aims of the present study were to measure soluble Cr(VI) levels in environmental samples, to develop a simple method of quantifying Cr(VI) in exhaled breath condensate (EBC), and to follow the kinetics of EBC Cr(VI) in chrome plating workers. Personal air samples were collected from 10 chrome platers; EBC was collected from the same workers immediately after the work shift on Tuesday and before the work shift on the following Wednesday. Environmental and EBC Cr(VI) levels were determined by means of colorimetry and electrothermal absorption atomic spectrometry, respectively. The method of detecting Cr(VI) in environmental air was based on the extraction of the Cr(VI)-diphenylcarbazide (Cr(VI)-DPC) complex in 1-butanol, whereas EBC Cr(VI) was determined using a solvent extraction of Cr(VI) as an ion pair with tetrabutylammonium ion, and subsequent direct determination of the complex (Cr(VI)-DPC) in EBC. Kinetic data showed that airborne Cr(VI) was reduced by 50% in airway lining fluid sampled at the end of exposure and that there was a further 50% reduction after about 15 h. The persistence of Cr(VI) in EBC supports the use of EBC in assessing target tissue levels of Cr(VI)

  7. R and D on Radiation Hard Active Media Based on Quartz Plates

    CERN Document Server

    Onel, Yasar

    2014-01-01

    The need for radiation-hard active media in particle detectors is prominently dictated by the future colliders and the future operations of the Large Hadron Collider. The areas of implementation range from calorimetry to beamline instrumentation to specialized forward detectors e.g. luminosity monitors. In this context, we developed the idea of utilizing quartz plates with various surface coating properties as the active medium for such detectors. Plain quartz is a pure Cerenkov radiator which has quite limited photostatistics. In order to improve the efficiency of the photodetection, various methods were investigated including radiation hard wavelength shifters, p-terphenyl or 4pct gallium doped zinc oxide. The readout options include direct coupling of the photodetector to the quartz plate, or fibers. We have studied various geometries and readout options and constructed calorimeter prototypes. Here we report on the results of the previous tests, and the recent developments, which enable several factors of ...

  8. Imaging of soft and hard materials using a Boersch phase plate in a transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Alloyeau, D., E-mail: alloyeau.damien@gmail.com [National Center for Electron Microscopy, Lawrence Berkeley National Laboratory, One Cyclotron Road, MS/72, Berkeley, CA 94720 (United States); Hsieh, W.K. [National Center for Electron Microscopy, Lawrence Berkeley National Laboratory, One Cyclotron Road, MS/72, Berkeley, CA 94720 (United States); Anderson, E.H.; Hilken, L. [Center for X-ray Optics, Lawrence Berkeley National Laboratory, Berkeley CA 94720 (United States); Benner, G. [Carl Zeiss NTS GmbH, Oberkochen 73447 (Germany); Meng, X. [Electrical Engineering and Computer Sciences, UC Berkeley, Berkeley, CA 94720-1770 (United States); Chen, F.R. [Department of Engineering and System Science, National Tsing Hua University, Hsinchu, Taiwan (China); Kisielowski, C. [National Center for Electron Microscopy, Lawrence Berkeley National Laboratory, One Cyclotron Road, MS/72, Berkeley, CA 94720 (United States)

    2010-04-15

    Using two levels of electron beam lithography, vapor phase deposition techniques, and FIB etching, we have fabricated an electrostatic Boersch phase plate for contrast enhancement of weak phase objects in a transmission electron microscope. The phase plate has suitable dimensions for the imaging of small biological samples without compromising the high-resolution capabilities of the microscope. A micro-structured electrode allows for phase tuning of the unscattered electron beam, which enables the recording of contrast enhanced in-focus images and in-line holograms. We have demonstrated experimentally that our phase plate improves the contrast of carbon nanotubes while maintaining high-resolution imaging performance, which is demonstrated for the case of an AlGaAs heterostructure. The development opens a new way to study interfaces between soft and hard materials.

  9. Effect of tempering on the microstructure and hardness of ledeburitic chromium steel X155CrVMo12.1

    Energy Technology Data Exchange (ETDEWEB)

    Markoli, B.; Spaic, S. [Ljubljana Univ. (Slovenia). Dept. of Materials and Metallurgy

    2007-02-15

    Ledeburitic chromium steel X155CrVMo12.1 for coldwork tools was investigated in the quenched and tempered condition. Using appropriate investigative methods the evolution of the microstructure in all conditions was characterized. The change in state of a multicomponent matrix during tempering is crucial for attaining the required properties of this steel. In the material investigated, shape, size, fraction and distribution of eutectic (primary) carbides played a secondary role. The evolution of tempered martensite and precipitation of secondary hardening carbides of M{sub 23}C{sub 6} -type and MC-type from the supersaturated matrix during tempering led to secondary hardening and a secondary hardness peak at about 530 C. The results show that steel X155CrVMo12.1 also exhibits performance ability at moderately elevated temperatures. (orig.)

  10. Elevated Frequencies of Micronuclei and other Nuclear Abnormalities of Chrome Plating Workers Occupationally Exposed to Hexavalent Chromium.

    Science.gov (United States)

    Sudha, S; Kripa, S K; Shibily, P; Shyn, J

    2011-01-01

    Biomonitoring provides a useful tool to estimate the genetic risk from exposure to genotoxic agents. The aim of this study was to assess the potential cytogenetic damage associated with occupational exposure to hexavalent chromium by using micronuclei (MN) as a biomarker. This was a cross-sectional study and all participants were males. Both the exposed and control individuals were selected from Coimbatore, Southern India. Exfoliated buccal cells from 44 chrome plating workers and 40 age and sex matched control subjects were examined for MN frequency and nuclear abnormalities (NA) other than micronuclei, such as binucleates, broken eggs, karyorrhexis, karyolysis and pyknosis. Results showed statistically significant difference between chrome plating workers and control groups. MN and NA frequencies in chrome plating workers were significantly higher than those in control groups (p chrome plating workers are under risk of significant cytogenetic damage. Therefore, there is a need to educate those who work with heavy metals about the potential hazard of occupational exposure and the importance of using protective measures.

  11. Fresnel zone plate with apodized aperture for hard X-ray Gaussian beam optics.

    Science.gov (United States)

    Takeuchi, Akihisa; Uesugi, Kentaro; Suzuki, Yoshio; Itabashi, Seiichi; Oda, Masatoshi

    2017-05-01

    Fresnel zone plates with apodized apertures [apodization FZPs (A-FZPs)] have been developed to realise Gaussian beam optics in the hard X-ray region. The designed zone depth of A-FZPs gradually decreases from the center to peripheral regions. Such a zone structure forms a Gaussian-like smooth-shouldered aperture function which optically behaves as an apodization filter and produces a Gaussian-like focusing spot profile. Optical properties of two types of A-FZP, i.e. a circular type and a one-dimensional type, have been evaluated by using a microbeam knife-edge scan test, and have been carefully compared with those of normal FZP optics. Advantages of using A-FZPs are introduced.

  12. Nanofocusing of hard X-ray free electron laser pulses using diamond based Fresnel zone plates

    Science.gov (United States)

    David, C.; Gorelick, S.; Rutishauser, S.; Krzywinski, J.; Vila-Comamala, J.; Guzenko, V. A.; Bunk, O.; Färm, E.; Ritala, M.; Cammarata, M.; Fritz, D. M.; Barrett, R.; Samoylova, L.; Grünert, J.; Sinn, H.

    2011-08-01

    A growing number of X-ray sources based on the free-electron laser (XFEL) principle are presently under construction or have recently started operation. The intense, ultrashort pulses of these sources will enable new insights in many different fields of science. A key problem is to provide x-ray optical elements capable of collecting the largest possible fraction of the radiation and to focus into the smallest possible focus. As a key step towards this goal, we demonstrate here the first nanofocusing of hard XFEL pulses. We developed diamond based Fresnel zone plates capable of withstanding the full beam of the world's most powerful x-ray laser. Using an imprint technique, we measured the focal spot size, which was limited to 320 nm FWHM by the spectral band width of the source. A peak power density in the focal spot of 4×1017 W/cm2 was obtained at 70 fs pulse length.

  13. Comparative of the Tribological Performance of Hydraulic Cylinders Coated by the Process of Thermal Spray HVOF and Hard Chrome Plating

    Directory of Open Access Journals (Sweden)

    R.M. Castro

    2014-03-01

    Full Text Available Due to the necessity of obtaining a surface that is resistant to wear and oxidation, hydraulic cylinders are typically coated with hard chrome through the process of electroplating process. However, this type of coating shows an increase of the area to support sealing elements, which interferes directly in the lubrication of the rod, causing damage to the seal components and bringing oil leakage. Another disadvantage in using the electroplated hard chromium process is the presence of high level hexavalent chromium Cr+6 which is not only carcinogenic, but also extremely contaminating to the environment. Currently, the alternative process of high-speed thermal spraying (HVOF - High Velocity Oxy-Fuel, uses composite materials (metal-ceramic possessing low wear rates. Research has shown that some mechanical properties are changed positively with the thermal spray process in industrial applications. It is evident that a coating based on WC has upper characteristics as: wear resistance, low friction coefficient, with respect to hard chrome coatings. These characteristics were analyzed by optical microscopy, roughness measurements and wear test.

  14. Chromium-Makes stainless steel stainless

    Science.gov (United States)

    Kropschot, S.J.; Doebrich, Jeff

    2010-01-01

    Chromium, a steely-gray, lustrous, hard metal that takes a high polish and has a high melting point, is a silvery white, hard, and bright metal plating on steel and other material. Commonly known as chrome, it is one of the most important and indispensable industrial metals because of its hardness and resistance to corrosion. But it is used for more than the production of stainless steel and nonferrous alloys; it is also used to create pigments and chemicals used to process leather.

  15. Removal of chromium from synthetic plating waste by zero-valent iron and sulfate-reducing bacteria.

    Science.gov (United States)

    Guha, Saumyen; Bhargava, Puja

    2005-01-01

    Experiments were conducted to evaluate the potential of zero-valent iron and sulfate-reducing bacteria (SRB) for reduction and removal of chromium from synthetic electroplating waste. The zero-valent iron shows promising results as a reductant of hexavalent chromium (Cr+6) to trivalent chromium (Cr+3), capable of 100% reduction. The required iron concentration was a function of chromium concentration in the waste stream. Removal of Cr+3 by adsorption or precipitation on iron leads to complete removal of chromium from the waste and was a slower process than the reduction of Cr+6. Presence SRB in a completely mixed batch reactor inhibited the reduction of Cr+6. In a fixed-bed column reactor, SRB enhanced chromium removal and showed promising results for the treatment of wastes with low chromium concentrations. It is proposed that, for waste with high chromium concentration, zero-valent iron is an efficient reductant and can be used for reduction of Cr+6. For low chromium concentrations, a SRB augmented zero-valent iron and sand column is capable of removing chromium completely.

  16. On texture formation of chromium electrodeposits

    DEFF Research Database (Denmark)

    Nielsen, Christian Bergenstof; Leisner, Peter; Horsewell, Andy

    1998-01-01

    The microstructure, texture and hardness of electrodeposited hard, direct current (DC) chromium and pulsed reversed chromium has been investigated. These investigations suggest that the growth and texture of hard chromium is controlled by inhibition processes and reactions. Further, it has been e...

  17. Tapered tilted linear zone plates for focusing hard x-rays

    Science.gov (United States)

    Ocola, Leonidas E.; Maser, Joerg; Vogt, Stefan; Lai, Barry; Divan, Ralu; Stephenson, Gregory B.

    2004-11-01

    We introduce a new design of tilted linear zone plates, which are named tapered tilted linear (TTL) zone plates. The purpose of the design is to increase efficiency while at the same time keeping the focal plane perpendicular to the optical path. In order to accomplish this, the zone radius and number of zones must become a function of position along the structure. Simulation work described in this paper shows improved optical performance over regular tilted linear zone plates.

  18. Modacrylic anion-exchange fibers for Cr(VI) removal from chromium-plating rinse water in batch and flow-through column experiments.

    Science.gov (United States)

    Lee, Seung-Chan; Kang, Jin-Kyu; Sim, Eun-Hye; Choi, Nag-Choul; Kim, Song-Bae

    2017-11-10

    The aim of this study was to investigate Cr(VI) removal from chromium-plating rinse water using modacrylic anion-exchange fibers (KaracaronTM KC31). Batch experiments were performed with synthetic Cr(VI) solutions to characterize the KC31 fibers in Cr(VI) removal. Cr(VI) removal by the fibers was affected by solution pH; the Cr(VI) removal capacity was the highest at pH 2 and decreased gradually with a pH increase from 2 to 12. In regeneration and reuse experiments, the Cr(VI) removal capacity remained above 37.0 mg g(-1) over five adsorption-desorption cycles, demonstrating that the fibers could be successfully regenerated with NaCl solution and reused. The maximum Cr(VI) removal capacity was determined to be 250.3 mg g(-1) from the Langmuir model. In Fourier-transform infrared spectra, a Cr = O peak newly appeared at 897 cm(-1) after Cr(VI) removal, whereas a Cr-O peak was detected at 772 cm(-1) due to the association of Cr(VI) ions with ion-exchange sites. X-ray photoelectron spectroscopy analyses demonstrated that Cr(VI) was partially reduced to Cr(III) after the ion exchange on the surfaces of the fibers. Batch experiments with chromium-plating rinse water (Cr(VI) concentration = 1178.8 mg L(-1)) showed that the fibers had a Cr(VI) removal capacity of 28.1-186.4 mg g(-1) under the given conditions (fiber dose = 1-10 g L(-1)). Column experiments (column length = 10 cm, inner diameter = 2.5 cm) were conducted to examine Cr(VI) removal from chromium-plating rinse water by the fibers under flow-through column conditions. The Cr(VI) removal capacities for the fibers at flow rates of 0.5 and 1.0 mL min(-1) were 214.8 and 171.5 mg g(-1), respectively. This study demonstrates that KC31 fibers are effective in the removal of Cr(VI) ions from chromium-plating rinse water.

  19. Effect of a Shot Peening Pre Treatment on the Fatigue Behaviour of Hard Chromium on Electroless Nickel Interlayer Coated AISI 4340 Aeronautical Steel

    Directory of Open Access Journals (Sweden)

    Nascimento Marcelino P.

    2002-01-01

    Full Text Available Multiple layer systems of coatings are considered to have larger resistance to crack propagation in comparison to coatings with simple layer. With regard to fatigue, it is possible to improve the resistance of a component with the application of shot peening treatment, whose compressive residual stresses delay or eliminate the initiation and propagation of fatigue cracks. The aim of this study is to analyse the effects on rotating bending fatigue behaviour of hard chromium fraction three-quarters electroless nickel multilayer system coated AISI 4340 high strength steel submitted to shot peening pre treatment. Results indicated that the interaction between the shot peening process with the multilayer system was not satisfactory, resulting in intense delamination. Fracture surface analysis by SEM was performed toward to identify the fatigue crack origin, as well as the coating-substrate delamination process.

  20. Hardness and microstructural response to thermal annealing of irradiated ASTM A533B class 1 plate steel

    Energy Technology Data Exchange (ETDEWEB)

    Reinhart, D.E. [SMS Concast, Inc., Pittsburgh, PA (United States); Kumar, A.S. [Univ. of Missouri, Rolla, MO (United States); Gelles, D.S.; Hamilton, M.L. [Pacific Northwest Lab., Richland, WA (United States); Rosinski, S.T. [Electric Power Research Inst., Charlotte, NC (United States)

    1999-10-01

    Hardness measurements were used to determine the post-irradiation annealing response of A533B class 1 plate steel irradiated to a fluence of 1 {times} 10{sup 19} n/cm{sup 2} (E > 1 MeV) at 150 C. Rockwell hardness measurements indicated that the material had hardened by 6.6 points on the B scale after irradiation. The irradiation induced hardness increase was associated with a decrease in upper shelf energy from 63.4 J to 5-1.8 J and a temperature shift in the Charpy curve at the 41 J level from 115 C to 215 C. Specimens were annealed after irradiation at temperatures of 343 C (650 F), 399 C (750 F), and 454 C (850 F) for durations of up to one week (168 h). Hardness measurements were made to chart recovery of hardness as a function of time and temperature. Specimens annealed at the highest temperature 454 C recovered the fastest, fully recovering within 144 h. Specimens annealed at 399 C recovered completely within 168 h. Specimens annealed at the lowest temperature, 343 C recovered only {approximately}70% after 168 h of annealing. After neutron irradiation, a new feature of black spot damage was found to be superimposed on the unirradiated microstructure. The density of black spots was found to vary from 2.3 {times} 10{sup 15}/cm{sup 3} to 1.1 {times} 10{sup 16}/cm{sup 3} with an average diameter of 2.85 nm. Following annealing at 454 C for 24 h the black spot damage was completely annealed out. It was concluded that the black spot damage was responsible for 70% of the irradiation-induced hardness.

  1. Spreading of nonmotile bacteria on a hard agar plate: Comparison between agent-based and stochastic simulations

    Science.gov (United States)

    Rana, Navdeep; Ghosh, Pushpita; Perlekar, Prasad

    2017-11-01

    We study spreading of a nonmotile bacteria colony on a hard agar plate by using agent-based and continuum models. We show that the spreading dynamics depends on the initial nutrient concentration, the motility, and the inherent demographic noise. Population fluctuations are inherent in an agent-based model, whereas for the continuum model we model them by using a stochastic Langevin equation. We show that the intrinsic population fluctuations coupled with nonlinear diffusivity lead to a transition from a diffusion limited aggregation type of morphology to an Eden-like morphology on decreasing the initial nutrient concentration.

  2. Simulation and experimental study of aspect ratio limitation in Fresnel zone plates for hard-x-ray optics.

    Science.gov (United States)

    Liu, Jianpeng; Shao, Jinhai; Zhang, Sichao; Ma, Yaqi; Taksatorn, Nit; Mao, Chengwen; Chen, Yifang; Deng, Biao; Xiao, Tiqiao

    2015-11-10

    For acquiring high-contrast and high-brightness images in hard-x-ray optics, Fresnel zone plates with high aspect ratios (zone height/zone width) have been constantly pursued. However, knowledge of aspect ratio limits remains limited. This work explores the achievable aspect ratio limit in polymethyl methacrylate (PMMA) by electron-beam lithography (EBL) under 100 keV, and investigates the lithographic factors for this limitation. Both Monte Carlo simulation and EBL on thick PMMA are applied to investigate the profile evolution with exposure doses over 100 nm wide dense zones. A high-resolution scanning electron microscope at low acceleration mode for charging free is applied to characterize the resultant zone profiles. It was discovered for what we believe is the first time that the primary electron-beam spreading in PMMA and the proximity effect due to extra exposure from neighboring areas could be the major causes of limiting the aspect ratio. Using the optimized lithography condition, a 100 nm zone plate with aspect ratio of 15/1 was fabricated and its focusing property was characterized at the Shanghai Synchrotron Radiation Facility. The aspect ratio limit found in this work should be extremely useful for guiding further technical development in nanofabrication of high-quality Fresnel zone plates.

  3. Multilayer on-chip stacked Fresnel zone plates: Hard x-ray fabrication and soft x-ray simulations

    Energy Technology Data Exchange (ETDEWEB)

    Li, Kenan; Wojcik, Michael J.; Ocola, Leonidas E.; Divan, Ralu; Jacobsen, Chris

    2015-11-01

    Fresnel zone plates are widely used as x-ray nanofocusing optics. To achieve high spatial resolution combined with good focusing efficiency, high aspect ratio nanolithography is required, and one way to achieve that is through multiple e-beam lithography writing steps to achieve on-chip stacking. A two-step writing process producing 50 nm finest zone width at a zone thickness of 1.14 µm for possible hard x-ray applications is shown here. The authors also consider in simulations the case of soft x-ray focusing where the zone thickness might exceed the depth of focus. In this case, the authors compare on-chip stacking with, and without, adjustment of zone positions and show that the offset zones lead to improved focusing efficiency. The simulations were carried out using a multislice propagation method employing Hankel transforms.

  4. Hard X-ray texture measurements with an on-line image plate detector

    CERN Document Server

    Wcislak, L; Tschentscher, T; Klein, H; Bunge, H J

    2001-01-01

    An instrument for diffraction texture measurements in polycrystalline bulk materials using hard X-ray photons from the wiggler beamline BW5 at HASYLAB is described. High-energy photons in the 100 keV regime enable high penetration power in medium-to-high Z materials and the use of Laue diffraction geometry in combination with a two-dimensional area detector allows fast and convenient data collection. Determination of quantitative, high-resolution pole figures with a better angular resolution of 0.1 deg. is attained by the instrument. Profile analysis of the diffraction pattern parameters for each (h k l)-reflection thus provides, in addition to texture data, information about other microstructural quantities, e.g. lattice strain.

  5. A hard X-ray study of a manganese-terpyridine catalyst in a chromium-based Metal Organic Framework

    Energy Technology Data Exchange (ETDEWEB)

    Ramsey, Alexandra V. [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2015-08-28

    Hydrogen produced from water splitting is a promising source of clean energy. However, a robust catalyst is necessary to carry out the water oxidation step of water splitting. In this study, the catalyst studied was [(terpy)Mn(μ-O)2Mn(terpy)]3+ (MnTD) synthesized in the Metal Organic Framework (MOF) MIL-101(Cr), and the method used for analysis was hard X-ray powder diffraction. The diffraction data was used to detect the presence of MOF in different catalytic stages, and lattice parameters were assigned to the samples containing MOF. Fourier maps were constructed with GSAS II to determine the contents of the MOF as preliminary studies suggested that MnTD may not be present. Results showed that MOF is present before catalysis occurs but disappears by the time 45 minutes of catalysis has ensued. Changes in the MOF’s lattice parameters and location of electron density in the Fourier maps suggest attractions between the MOF and catalyst that may lead to MOF degradation. Fourier maps also revealed limited, if any, amounts of MnTD, even before catalysis occurred. Molecular manganese oxide may be the source of the high rate of water oxidation catalysis in the studied system.

  6. Analysis of residual stress and hardness in regions of pre-manufactured and manual bends in fixation plates for maxillary advancement.

    Science.gov (United States)

    Araújo, Marcelo Marotta; Lauria, Andrezza; Mendes, Marcelo Breno Meneses; Claro, Ana Paula Rosifini Alves; Claro, Cristiane Aparecida de Assis; Moreira, Roger William Fernandes

    2015-12-01

    The aim of this study was to analyze, through Vickers hardness test and photoelasticity analysis, pre-bent areas, manually bent areas, and areas without bends of 10-mm advancement pre-bent titanium plates (Leibinger system). The work was divided into three groups: group I-region without bend, group II-region of 90° manual bend, and group III-region of 90° pre-fabricated bends. All the materials were evaluated through hardness analysis by the Vickers hardness test, stress analysis by residual images obtained in a polariscope, and photoelastic analysis by reflection during the manual bending. The data obtained from the hardness tests were statistically analyzed using ANOVA and Tukey's tests at a significance level of 5 %. The pre-bent plate (group III) showed hardness means statistically significantly higher (P < 0.05) than those of the other groups (I-region without bends, II-90° manually bent region). Through the study of photoelastic reflection, it was possible to identify that the stress gradually increased, reaching a pink color (1.81 δ / λ), as the bending was performed. A general analysis of the results showed that the bent plate region of pre-bent titanium presented the best results.

  7. A Hard X-ray Study of a Manganese-Terpyridine Dimer Catalyst in a Chromium-based Metal Organic Framework - Oral Presentation

    Energy Technology Data Exchange (ETDEWEB)

    Ramsey, Alexandra [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2015-08-25

    Cleaner forms of energy are needed, and H2 produced from water spliFng is a possible source. However, a robust catalyst is necessary to carry out the water oxidaKon reacKon. Plants uKlize Photosystem II to catalyze water oxidaKon as a part of photosynthesis, and many syntheKc water oxidaKon catalysts use Photosystem II as a model. In this study, the catalyst of interest was [(terpy)Mn(μ-O)2Mn(terpy)]3+ (MnTD), which was synthesized in a chromium-based Metal Organic Framework (MOF) to avoid degradaKon of MnTD molecules. Hard X-ray powder diffracKon was the primary method of analysis. The diffracKon data was used to detect the presence of MOF in samples at different catalyKc stages, and laFce parameters were assigned to the samples containing MOF. Fourier maps were constructed to determine the contents of the MOF as preliminary studies suggested that MnTD may not be present. Results showed that MOF is present before catalysis occurs, but disappears in the iniKal stages of catalysis. Changes in the MOF’s laFce parameters suggest aWracKve interacKons between the MOF and catalyst; these interacKons may lead to the observed MOF degradaKon. Fourier maps also reveal limited, if any, amounts of MnTD in the system. Molecular manganese oxide may be the source of the high rate of water oxidaKon catalysis in the studied system.

  8. PLATE

    DEFF Research Database (Denmark)

    Kling, Joyce; Hjulmand, Lise-Lotte

    2008-01-01

    the Project in Language Assessment for Teaching in English (PLATE) language professionals from CBS’s Language Center observe teachers and provide feedback using evaluation criteria from the Common European Framework for Reference (CEFR) supplemented by some additional criteria which take the LSP nature......’s level of English is sufficient for the increasing number of courses offered in English each semester. This paper addresses these concerns and describes a pilot project initiated in 2003 at CBS to gauge the overall English language proficiency of those teaching content courses in English. Through...

  9. Investigation of the influence of cementation of chromium onto aluminium on the characteristics of non-printing elements of an offset printing plate

    Directory of Open Access Journals (Sweden)

    Živković Predrag M.

    2004-01-01

    Full Text Available The possibility of the electro less deposition of chromium onto aluminum was investigated in order to improve non-printing element properties. It was determined that the electrochemical deposition of trivalent chromium was possible from alkaline solutions. The presence of chromium was confirmed by the EDAX procedure in three different laboratories. The influence of chromium on the wet ability of the nonprinting elements of the printing form was examined by drop spreading. Specimens were examined by pouring distilled water in drops onto the surface of the specimen. The picture of the drop was taken by a digital camera from two directions, in order to measure the diameter of the spreaded drop (a measuring gauge was recorded together with the drop and contact angle. The chromium-treated samples showed increased wettability compared with the non-chromium-treated samples. Improvement of the non-printing elements was confirmed during a printing test that was performed under real printing conditions. The purity of the prints made by two types of printing forms was analyzed in two ways: based on densitometric measurements and based on statistical analysis of the scanned print. Both methods of analysis of the control prints showed that the control prints made from chromium-treated specimens were purer than the prints made from the non-chromium-treated specimens. Considering that all the conditions of making the printing forms and the printing conditions, except the electro less deposition procedure were the same, it could be concluded that the electro less deposited layer of chromium improved the printing properties of the offset printing form because of the increased wettability.

  10. CAPSULE REPORT: HARD CHROME FUME ...

    Science.gov (United States)

    All existing information which includes the information extrapolated from the Hard Chrome Pollution Prevention Demonstration Project(s) and other sources derived from plating facilities and industry contacts, will be condensed and featured in this document. At least five chromium emission prevention/control devices have been tested covering a wide spectrum of techniques currently in use at small and large-sized chrome metal plating shops. The goal for limiting chromium emissions to levels specified in the MACT Standards are: (1) 0.030 milligrams per dry standard cubic meter of air (mg/dscm) for small facilities with existing tanks, (2) 0.015 mg/dscm for small facilities with new tanks or large facilities with existing or new tanks. It should be emphasized that chemical mist suppressants still have quality issues and work practices that need to be addressed when they are used. Some of the mist suppressants currently in use are: one-, two-, and three-stage mesh pad mist eliminators; composite mesh pad mist eliminators; packed-bed scrubbers and polyballs. This capsule report should, redominantly, emphasize pollution prevention techniques and include, but not be restricted to, the afore-mentioned devices. Information

  11. A preliminary study on pressure-plate evaluation of forelimb toe-heel and mediolateral hoof balance on a hard vs. a soft surface in sound ponies at the walk and trot

    NARCIS (Netherlands)

    Oosterlinck, M; Royaux, E; Back, W; Pille, F

    2014-01-01

    REASONS FOR PERFORMING STUDY: Thus far, pressure-plate analysis has been limited to measurements on a hard surface, whereas equine athletes routinely perform on a deformable substrate. OBJECTIVES: To explore pressure-plate analysis on arena footing. STUDY DESIGN: Nonrandomised crossover study using

  12. Scanning hard X-ray microscope with tantalum phase zone plate at the Hyogo-BL (BL24XU) of SPring-8

    CERN Document Server

    Kagoshima, Y; Ibuki, T; Yokoyama, Y; Hashida, T; Yokoyama, K; Takeda, S; Urakawa, M; Miyamoto, N; Tsusaka, Y; Matsui, J; Aino, M

    2001-01-01

    A scanning hard X-ray microscope using a phase zone plate made of tantalum as its X-ray focusing device is in operation at the Hyogo-BL (BL24XU) of SPring-8. The X-ray microbeam has a size of 0.8 mu mx0.7 mu m at the photon energy of 10 keV, which can make visible structures as fine as 250-nm line-and-space pattern. The photon flux density at the sample position is approx 2x10 sup 9 phs/s/mu m sup 2 and the gain of the phase zone plate is approx 3000. The minimum detection limits irradiated by the microbeam are evaluated to be around 10 ppm for some trace elements contained in standard reference materials of glass matrices. X-ray images obtained so far demonstrate a high feasibility of the microscope.

  13. Submental Artery Island Flap in Reconstruction of Harde Plate after wide Surgical Resection of Veruccous Carcinoma. Two case reports

    Directory of Open Access Journals (Sweden)

    Amin Rahpeyma

    2013-06-01

    Full Text Available Introduction: Reconstruction of intraoral soft tissue defects is important in restoring function and esthetic. In large defects, there will be demand for regional pedicle flaps or free flaps. Hard palate separates nasal and oral cavities. Due to the small surface area between flap and remaining palate after surgical resections, optimal blood supply of the flaps for hard palate reconstructions are needed. This article demonstrates immediate reconstruction of two edentulous hemimaxillectomy patients with submental artery Island flap and brief review of this flap discussed. 

  14. Evidence for a Cr metastable phase as a tracer in DLI-MOCVD chromium hard coatings usable in high temperature environment

    Science.gov (United States)

    Michau, Alexandre; Maury, Francis; Schuster, Frederic; Boichot, Raphael; Pons, Michel

    2017-11-01

    Cr deposits are widely used as protective coatings but multifunctional performances are required in harsh environments motivating research on new processes. MOCVD of Cr metal coatings was carried out by direct liquid injection (DLI) of a unique solution containing bis(ethylbenzene)chromium as metal source and thiophenol as inhibitor of carbide formation. A low amount (affected by the structural transformation because of the similarity of their crystallographic structures (both cubic), their density very close (a volume contraction of only 0.4% during the transformation) and its low content. This metastable phase is a signature of the DLI-MOCVD process and it can be used as a tracer for Cr coatings operating in high temperature environment without loss of the basic properties.

  15. Preliminary design of a zone plate based hard X-ray monochromatic diffraction nanoprobe for materials studies at APS

    Science.gov (United States)

    Cai, Zhonghou; Liu, Wenjun; Tischler, Jonathan Z.; Shu, Deming; Xu, Ruqing; Schmidt, Oliver

    2013-09-01

    Aiming at studies of the micro/nano-structures of a broad range materials and electronic devices, Advance Photon Source (APS) is developing a dedicated diffraction nanoprobe (DNP) beamline for the needs arising from a multidiscipline research community. As a part of the APS Upgrade Project, the planed facility, named Sub-micron 3-D Diffraction (S3DD) beamline1, integrates the K-B mirror based polychromatic Laue diffraction and the Fresnel zone-plate based monochromatic diffraction techniques that currently support 3D/2D microdiffraction programs at the 34-ID-E and 2-ID-D of the APS, respectively. Both diffraction nanoprobes are designed to have a 50-nm or better special resolution. The zone-plate based monochromatic DNP has been preliminarily designed and will be constructed at the sector 34-ID. It uses an APS-3.0-cm period or APS-3.3-cm period undulator, a liquid-nitrogen cooled mirror as its first optics, and a water cooled small gap silicon double-crystal monochromator with an energy range of 5-30 keV. A set of zone plates have been designed to optimize for focusing efficiency and the working distance based on the attainable beamline length and the beam coherence. To ensure the nanoprobe performance, high stiffness and high precision flexure stage systems have been designed or demonstrated for optics mounting and sample scanning, and high precision temperature control of the experimental station will be implemented to reduce thermal instability. Designed nanoprobe beamline has a good management on thermal power loading on optical components and allows high degree of the preservation of beam brilliance for high focal flux and coherence. Integrated with variety of X-ray techniques, planed facility provides nano-XRD capability with the maximum reciprocal space accessibility and allows micro/nano-spectroscopy studies with K-edge electron binding energies of most elements down to Vanadium in the periodic table. We will discuss the preliminary design of the zone-plate

  16. Comparison of Petrifilm Staph Express Count System with the bacteriological analytical manual direct-plating method for enumeration of Staphylococcus aureus in artificially contaminated hard cheese.

    Science.gov (United States)

    Fedio, Willis M; Wendakoon, Chitra N; Zapata, Ruben; Carrillo, Christina; Browning, Paul

    2008-01-01

    The 3M Petrifilm Staph Express Count System was compared with the U.S. Food and Drug Administration's Bacteriological Analytical Manual (BAM) direct-plate count method for the enumeration of Staphylococcus aureus in 6 types of artificially contaminated hard cheese (Asiago, Cheddar, Gruyère, Parmesan, Romano, and Swiss). Five different samples of each cheese type were inoculated with S. aureus (ATCC 25923) to achieve low, medium, and high inoculum levels. S. aureus was enumerated by the Petrifilm and BAM methods, and the results were compared. Multivariate analysis of variance revealed no significant differences (P<0.05) between the 2 methods. The Petrifilm method compared favorably with the BAM procedure. The rapid method was more convenient to use, considerably faster, and less expensive to perform than the BAM method.

  17. Temperature of Heating and Cooling of Massive, Thin, and Wedge-Shaped Plates from Hard-to-Machine Steels During Their Grinding

    Science.gov (United States)

    Dement‧ev, V. B.; Ivanova, T. N.; Dolginov, A. M.

    2017-01-01

    Grinding of flat parts occurs by solid abrasive particles due to the physicomechanical process of deformation and to the action of a process liquid at high temperatures in a zone small in volume and difficult for observation. The rate of heating and cooling depends on the change in the intensity of the heat flux and in the velocity and time of action of the heat source. A study has been made of the regularities of the influence of each of these parameters on the depth and character of structural transformations during the grinding of flat parts from hard-to-machine steels. A procedure to calculate temperature in grinding massive, thin, and wedge-shaped parts has been developed with account taken of the geometric and thermophysical parameters of the tool and the treated part, and also of cutting regimes. The procedure can be used as a constituent part in developing a system for automatic design of the technological process of grinding of flat surfaces. A relationship between the temperature in the grinding zone and the regimes of treatment has been established which makes it possible to control the quality of the surface layer of massive, thin, and wedge-shaped plates from hard-to-machine steels. The rational boundaries of shift of cutting regimes have been determined.

  18. A preliminary study on pressure-plate evaluation of forelimb toe-heel and mediolateral hoof balance on a hard vs. a soft surface in sound ponies at the walk and trot.

    Science.gov (United States)

    Oosterlinck, M; Royaux, E; Back, W; Pille, F

    2014-11-01

    Thus far, pressure-plate analysis has been limited to measurements on a hard surface, whereas equine athletes routinely perform on a deformable substrate. To explore pressure-plate analysis on arena footing. Nonrandomised crossover study using noninvasive techniques. Five sound, unshod ponies were walked and trotted over a pressure plate in 2 different conditions. In the first session, the plate was covered with only a 5 mm rubber mat, and in the second session, with an additional 50 mm layer of sand and synthetic fibres. Limb loading and timing variables (peak vertical force, vertical impulse, peak vertical pressure, hoof contact area and stance phase duration) were obtained. Toe-heel and mediolateral hoof balance of the vertical force were calculated throughout stance (126 Hz). Peak vertical force, vertical impulse, peak vertical pressure and stance phase duration were decreased on the soft substrate, while hoof contact area increased. At impact, there was more even load distribution between the toe and heel region on the soft vs. hard surface. At mid-stance, there was more loading of the toe region on the soft compared with the hard surface. At impact, there was more even load distribution between lateral and medial on the soft vs. hard surface at walk, but not at trot. Comparison of observed vs. expected impulse indicated that the main factor involved in the lower loading on the soft surface is the dampening effect of the soft substrate, although definitive conclusions require concurrent force-plate analysis. The pressure plate permitted quantitative evaluation of hoof balance of the vertical force on a deformable surface at the walk and trot and proved that there is more even load distribution on arena footing. © 2013 EVJ Ltd.

  19. Developing of chromium cast steel on sleeves of heavy machines

    OpenAIRE

    J. Kilarski; A. Studnicki; J. Suchoń

    2010-01-01

    The results of investigations of hardness, impact resistance, abrasive and corrosive wear of selected chromium cast steel with destination on sleeves of heavy machines were introduced in the article. First results of exploational investigations talked over on the end.

  20. Heterogeneous chromium catalysts

    OpenAIRE

    2005-01-01

    The present invention relates to a heterogeneous chromium catalyst system for the polymerisation of ethylene and/or alpha olefins prepared by the steps of: (a) providing a silica-containing support, (b) treating the silica-containing support with a chromium compound to form a chromium-based silica-containing support, (c) activating the chromium-based silica-containing support, (d) chemically reducing the activated chromium-based silica-containing support to produce a precursor catalyst, (e) r...

  1. Skin deposition of nickel, cobalt, and chromium in production of gas turbines and space propulsion components.

    Science.gov (United States)

    Julander, Anneli; Skare, Lizbet; Mulder, Marie; Grandér, Margaretha; Vahter, Marie; Lidén, Carola

    2010-04-01

    Skin exposure to nickel, cobalt, and chromium may cause sensitization and allergic contact dermatitis and it is known that many alloys and platings may release significant amounts of the metals upon contact with skin. Occupational exposure to these sensitizing metals has been studied in different settings with regards to airborne dust and different biological end points, but little is known about deposition on skin from airborne dust and direct contact with materials containing the metals. In this study, skin deposition was studied in 24 workers in an industry for development and manufacturing of gas turbines and space propulsion components. The workers were employed in three departments, representing different exposure scenarios: tools sharpening of hard metal items, production of space propulsion structures, and thermal application of different metal-containing powders. A novel acid wipe sampling technique was used to sample metals from specific skin surfaces on the hands and the forehead of the workers. Total amounts of nickel, cobalt, and chromium were measured by inductively coupled plasma mass spectrometry. The result showed that nickel, cobalt, and chromium could be detected on all skin surfaces sampled. The highest level of nickel was 15 microg cm(-2) h(-1), the highest for cobalt was 4.5 microg cm(-2) h(-1), and for chromium 0.6 microg cm(-2) h(-1). The three departments had different exposures regarding the metals. The highest levels of nickel on the skin of the workers were found in the thermal applications department, cobalt in the tools sharpening department, and chromium in the space propulsion components department. In conclusion, the workers' exposure to the metals was more likely to come from direct skin contact with items, rather than from airborne dust, based on the fact that the levels of metals were much higher on the fingers than on the back side of the hands and the forehead. The skin exposure levels of nickel and cobalt detected are judged

  2. Industrial Processes to Reduce Generation of Hazardous Waste at DoD Facilities. Phase III Report. Appendix B. Workshop Manual Innovative Hard Chrome Plating, Pensacola Naval Air Rework Facility, Pensacola, Florida.

    Science.gov (United States)

    1985-12-01

    Daniel Bostrom , S pec ial and Reid Dennis, of CH2M HILL, and Mary Savage of PEER. A Vala "VP&- PROJECT OF EXCELLENCE . INNOVATIVE HARD CHROME PLATING...test site, largely because of the contacts developed -" during previous work done at the NARF by NCEL. Contacts: Nick J. Olah, Project Engineer Charles J...COORDINATING PR OGRAM ASSISTANCE AT NAVAIR AND NAVSEA ACTIVITIES. POC AT NCEL IS MR. NICK OLAH, AV 360-4116 OR COMMERCIAL (805) 982-4116. 5. REQUEST ADVISE

  3. Chromium and Genomic Stability

    OpenAIRE

    Wise, Sandra S.; Wise, John Pierce

    2011-01-01

    Many metals serve as micronutrients which protect against genomic instability. Chromium is most abundant in its trivalent and hexavalent forms. Trivalent chromium has historically been considered an essential element, though recent data indicate that while it can have pharmacological effects and value, it is not essential. There are no data indicating that trivalent chromium promotes genomic stability and, instead may promote genomic instability. Hexavalent chromium is widely accepted as high...

  4. Heterogeneous chromium catalysts

    NARCIS (Netherlands)

    2005-01-01

    The present invention relates to a heterogeneous chromium catalyst system for the polymerisation of ethylene and/or alpha olefins prepared by the steps of: (a) providing a silica-containing support, (b) treating the silica-containing support with a chromium compound to form a chromium-based

  5. Humvee Armor Plate Drilling

    National Research Council Canada - National Science Library

    2004-01-01

    When drilling holes in hard steel plate used in up-armor kits for Humvee light trucks, the Anniston Army Depot, Anniston, Alabama, requested the assistance of the National Center for Defense Manufacturing and Machining (NCDMM...

  6. DESARROLLO DE UN SEPARADOR DE OBJETOS DUROS EN EL CAFÉ A PARTIR DE LAS VIBRACIONES PRODUCIDAS EN PLACAS DELGADAS DEVELOPMENT OF A SEPARATOR IN THE COFFEE HARD OBJECTS FROM THE VIBRATIONS PRODUCED IN THIN PLATES

    Directory of Open Access Journals (Sweden)

    Diego Agudelo Gómez

    2008-12-01

    Full Text Available En Cenicafé se diseñaron y construyeron prototipos electromecánicos denominados PESELOD (pescador electrónico de objetos duros para la protección de las máquinas despulpadoras. Este nuevo módulo, localizado antes de la despulpadora, está conformado por un alimentador, un cuerpo vibrante (placa delgada o cono metálico, una compuerta, un recipiente para los objetos duros desalojados y un circuito para la detección y separación automática del objeto duro. Su principio de funcionamiento se basa en la diferencia de los parámetros de amplitud y frecuencia de las vibraciones producidas en el impacto del café y de los objetos duros contra el cuerpo vibrante. Se realizó el análisis histórico en los espectros de las aceleraciones que se indujeron teniendo en cuenta variaciones del material, espesor y apoyo. En la caracterización se encontraron mejores características de separación para placas de 2,5 mm de espesor, simplemente soportada y de material acerado. Los prototipos presentaron eficacias superiores al 80% y rendimientos entre 300 y 2.000 kg h-1 de café en cereza. De igual manera se realizaron variaciones tendientes a mejorar su operabilidad, relacionada con la limpieza de las placas para lo cual se construyó otro prototipo cuyo cuerpo vibrante lo constituía un cono acerado.Electromechanical experimental models of an electronic separator of hard objects, denominated PESELOD (pescador electrónico de objetos duros, Spanish were designed and constructed in Cenicafé to protect the coffee processing machines. The module, located before the pulping machine, includes a feeder, a vibrant body (thin plate or metallic cone, a gate, a hard objects container and a circuit for both hard objects detection and automatic separation. Its principle of operation is based on the difference of amplitude and frequency of the vibrations produced by impact of coffee fruits and hard objects against a vibrant body. The historical analysis was made in

  7. HARD CHROME POLLUTION PREVENTION DEMONSTRATION PROJECT - INTERIM REPORT

    Science.gov (United States)

    In the project, five chromium emission prevention/control devices were tested tha cover the spectrum of prevention/control techniques currently in use in small- and large-size hard chromium electroplating job shops. The Project results show that some of the tested devices had ch...

  8. Lubrication characteristics of nano-oil with different degrees of surface hardness of sliding members.

    Science.gov (United States)

    Ku, Boncheol; Han, Youngcheol; Lee, Kwangho; Choi, Youngmin; Koo, Bonyoung; Hwang, Yujin; Lee, Jaekeun

    2011-01-01

    In this study, the lubrication characteristics of sliding members were compared with the changes in the hardness of friction surfaces and the application of nano-oil. The materials of the specimens were gray cast iron (AISI 35 and AISI 60) and nickel chromium molybdenum steel (AISI 4320). The friction coefficients and the temperature variations of the frictional surfaces were measured with a disk-on-disk tribotester under a fixed rotation speed. The friction surfaces were observed with a scanning electron microscope (SEM). The friction coefficients of the plate surface increased as the hardness difference increased. The friction coefficient after the lubrication with nano-oil was less than that after lubrication with mineral oil. This is because a spherical nanoparticle plays the role of a tiny ball bearing between the frictional surfaces that improve the lubrication characteristics.

  9. Chromium and Genomic Stability

    Science.gov (United States)

    Wise, Sandra S.; Wise, John Pierce

    2014-01-01

    Many metals serve as micronutrients which protect against genomic instability. Chromium is most abundant in its trivalent and hexavalent forms. Trivalent chromium has historically been considered an essential element, though recent data indicate that while it can have pharmacological effects and value, it is not essential. There are no data indicating that trivalent chromium promotes genomic stability and, instead may promote genomic instability. Hexavalent chromium is widely accepted as highly toxic and carcinogenic with no nutritional value. Recent data indicate that it causes genomic instability and also has no role in promoting genomic stability. PMID:22192535

  10. Influence of the laser pre-quenched substrate on an electroplated chromium coating/steel substrate

    Science.gov (United States)

    Chen, Xuejun; Yan, Qian; Ma, Qian

    2017-05-01

    The chromium coatings were electroplated onto a laser pre-quenched steel substrate to improve the interfacial adhesion properties of chromium coating/steel substrate system. The influence of laser pre-treatment on the substrate, coating as well as interface was investigated by using microstructure characterization, hardness testing, tensile testing and finite element analysis. An apparent boundary line instead of an interlayer was identified between chromium coating/pre-quenched steel substrate. The Vickers hardness and yield strength of steel substrate were significantly improved after laser pre-quenching. The fracture toughness of chromium coating was increased by about 28.6% compared to the un-treated counterpart. The energy release rate for an interfacial crack in the chromium coating/laser-quenched substrate was smaller than that in the untreated specimen. These results may help understand the life prolongation mechanism for the laser pre-quenched chromium/coated steel parts.

  11. A review of producing hard coatings by means of duplex treatments using an electroplated coating–thermochemical treatment combination

    Directory of Open Access Journals (Sweden)

    Héctor Cifuentes Aya

    2011-12-01

    Full Text Available Duplex treatments have been developed to overcome the disadvantages presented by simple treatments to surfaces of different materials and have, in a combined and complementary way, the properties that each of these methods supplies individually. The difference between thermal expansion coefficients for Fe and Cr in hard chrome plating leads to crack formation in the deposited coat, through which corrosive agents migrate and reduce the system’s integrity.Direct deposition by physical vapour deposition (PVD, used for obtaining chromium nitride films on steel substrates, is limited by high production costs, the low thickness obtained and low resistance to corrosion due to the presence of micro pores. Some studies have combined an electroplated chromium with thermochemical treatments made in a controlled atmosphere or vacuum furnaces or by plasma. This kind of duplex treatment allows compounds such as CrxN, CrxCyN and CrxCy to be obtained from chemical and micro structural transformation of chromium with nitrogen and/or carbon, the sealing of cracks in the coating and increasing the magnitude of properties like hardness and density, improving wear and abrasion and corrosion resistance.

  12. Sodium sulfur container with chromium/chromium oxide coating

    Science.gov (United States)

    Ludwig, Frank A.; Higley, Lin R.

    1981-01-01

    A coating of chromium/chromium oxide is disclosed for coating the surfaces of electrically conducting components of a sodium sulfur battery. This chromium/chromium oxide coating is placed on the surfaces of the electrically conducting components of the battery which are in contact with molten polysulfide and sulfur reactants during battery operation.

  13. MICROSTRUCTURE AND CORROSION RESISTANCE OF CHROMIUM NITRIDES OBTAINED BY VACUUM GAS NITRIDING OF ELECTROLYTIC CHROMIUM DEPOSITED ON AISI H13 STEEL

    Directory of Open Access Journals (Sweden)

    H. Cifuentes

    2013-06-01

    Full Text Available In this scientific research paper, the microstructure and corrosion resistance of chromium nitrides obtained from a duplex treatment consisting of an electroplated hard chromium coating applied on a steel AISI H13 follow by a thermochemical treatment in vacuum using NH3 as precursor gas of nitrogen, is evaluated. This type of duplex treatments combine the benefits of each individual treatment in order to obtain, with this synergic effect, compounds type CrxN more economic than those obtained by other kind of treatments e.g. physical vapor deposition (PVD. The results obtained by X-Ray Diffraction (XRD indicate the surface and subsurface transformation of the electrolytic hard chromium coating by formation of CrN and Cr2N phases. Likewise, potentiodynamic polarization tests indicate an increase in corrosion resistance of such kind of compounds in comparison with the obtained results with electroplated hard chromium.

  14. Microstructural characterisation of chromium slags

    OpenAIRE

    J. Burja; F. Tehovnik; Vode, F.; B. Arh

    2015-01-01

    In this chromium slags that form during melting of chromium alloyed steels are examined. During melting and oxidation of these steel grades a considerable amount of chromium is lost, and gained back with slag reduction. Laboratory experiments were performed to study the mechanism of chromium oxide reduction by silicon. Slags chemistry and phase composition have a strong effect on the steelmaking process. Phase analysis revealed two types of chromium oxides, calcium chromites and chromite spin...

  15. Chromium in diet

    Science.gov (United States)

    ... is important in the metabolism of fats and carbohydrates . It stimulates fatty acid and cholesterol synthesis, which are important for brain function and other body processes. Chromium also aids in insulin action and glucose metabolism.

  16. Integrated Criteria Document Chromium

    OpenAIRE

    Slooff W; Cleven RFMJ; Janus JA; van der Poel P; van Beelen P; Boumans LJM; Canton JH; Eerens HC; Krajnc EI; de Leeuw FAAM; Matthijsen AJCM; van de Meent D; van der Meulen A; Mohn GR; Wijland GC

    1990-01-01

    Betreft de engelse versie van rapport 758701001
    Bij dit rapport behoort een appendix onder hetzelfde nummer getiteld: "Integrated Criteria Document Chromium: Effects" Auteurs: Janus JA; Krajnc EI
    (appendix: see 710401002A)

  17. The carcinogenicity of chromium

    OpenAIRE

    Norseth, Tor

    1981-01-01

    The carcinogenicity of chromium compounds is reviewed with specific attention to the gaps in knowledge for risk estimation and research needs. The most important problems at present are whether trivalent chromium compounds cause cancer, and whether there is a difference in cancer causing effects between the soluble and the slightly soluble hexavalent compounds in the practical exposure situation. Dose estimates for risk estimation based on epidemiological investigations are also lacking. Pres...

  18. Developing of chromium cast steel on sleeves of heavy machines

    Directory of Open Access Journals (Sweden)

    J. Kilarski

    2010-10-01

    Full Text Available The results of investigations of hardness, impact resistance, abrasive and corrosive wear of selected chromium cast steel with destination on sleeves of heavy machines were introduced in the article. First results of exploational investigations talked over on the end.

  19. FEATURES OF CHROMIUM DOPING OF WEAR-RESISTANT CAST IRON

    Directory of Open Access Journals (Sweden)

    V. V. Netrebko

    2013-01-01

    Full Text Available The aim of this work analysis of the influence of chromium on the process of carbide formation, changes in chemical composition of the metal substrate in the areas adjacent to the carbides and at the hardness of iron while economy nickel and manganesealloying.

  20. Effect of Chromium on the Solidification Process and Microstructure of Vermicular Graphite Cast Iron

    Directory of Open Access Journals (Sweden)

    Gumienny G.

    2015-09-01

    Full Text Available The paper presents the results of studies of the effect of chromium concentration on the solidification process, microstructure and selected properties of cast iron with vermicular graphite. The vermicular graphite cast iron was obtained by an Inmold process. Studies covered the cast iron containing chromium in a concentration at which graphite is still able to preserve its vermicular form. The effect of chromium on the temperature of eutectic crystallization and on the temperature of the start and end of austenite transformation was discussed. The conditions under which, at a predetermined chromium concentration, the vermicular graphite cast iron of a pearlitic matrix is obtained were presented, and the limit concentration of chromium was calculated starting from which partial solidification of the cast iron in a metastable system takes place. The effect of chromium on the hardness of cast iron, microhardness of individual phases and surface fraction of carbides was disclosed.

  1. Design and performance of chromium mist generator

    Directory of Open Access Journals (Sweden)

    Tirgar Aram

    2006-01-01

    Full Text Available Chromium mist generator is an essential tool for conducting researches and making science-based recommendations to evaluate air pollution and its control systems. The purpose of this research was to design and construct a homogenous chromium mist generator and the study of some effective factors including sampling height and distances between samplers in side-by-side sampling on chromium mist sampling method. A mist generator was constructed, using a chromium electroplating bath in pilot scale. Concentration of CrO3 and sulfuric acid in plating solution was 125 g L-1 and 1.25 g L-1, respectively. In order to create permanent air sampling locations, a Plexiglas cylindrical chamber (75 cm height, 55 cm i.d was installed the bath overhead. Sixty holes were produced on the chamber in 3 rows (each 20. The distance between rows and holes was 15 and 7.5 cm, respectively. Homogeneity and effective factors were studied via side-by-side air sampling method. So, 48 clusters of samples were collected on polyvinyl chloride (PVC filters housed in sampling cassettes. Cassettes were located in 35, 50, and 65 cm above the solution surface with less than 7.5 and/or 7.5-15 cm distance between heads. All samples were analyzed according to the NIOSH method 7600. According to the ANOVA test, no significant differences were observed between different sampling locations in side-by-side sampling (P=0.82 and between sampling heights and different samplers distances (P=0.86 and 0.86, respectively. However, there were notable differences between means of coefficient of variations (CV in various heights and distances. It is concluded that the most chromium mist homogeneity could be obtained at height 50 cm from the bath solution surface and samplers distance of < 7.5 cm.

  2. Electroless Ni-B plating for electrical contact applications

    Directory of Open Access Journals (Sweden)

    Dervos, C. T.

    2005-12-01

    Full Text Available Electroless Ni-B plating has been tried on steel substrate in an effort to employ low-cost starting materials for electrical contacts or connectors. By selected conditions of heat treatment in a high vacuum environment the plating can acquire Cr-equivalent hardness without the effluents of the hard chromium plating process. The surfaces were characterized under scanning electron microscope and by XRD. The fabricated materials were tested under corrosion conditions by polarization measurements. Semispherical nickel plated steel joints were tested in a computer controlled contact make-break apparatus, under simultaneous application of a mechanical and a low-voltage electrical load for 20,000 cycles. After heat treatment the plating acquires a crystalline structure with very good adhesion to the substrate material. Corrosion decreases and increased hardness is obtained. The surface is also characterized by good electrical properties during aging accelerated tests.

    Se ha investigado la deposición de Ni-B por vía química sobre un substrato de acero, con el fin de poder emplear materiales de bajo coste para los contactos o conectores eléctricos. Mediante condiciones específicas de tratamiento térmico en un ambiente de alto vacío, la deposición puede alcanzar durezas equivalentes al cromo (Cr sin los efluentes del proceso de cromado duro. Las superficies se caracterizaron en el microscopio electrónico de barrido y mediante DRX. Los materiales fabricados se ensayaron bajo condiciones de corrosión utilizando mediciones de polarización. Se ensayaron las juntas semiesféricas de acero niquelado en un equipo de contactos controlado por ordenador bajo la aplicación simultánea de una carga mecánica y de una carga eléctrica de bajo voltaje durante 20.000 ciclos. Después del tratamiento térmico, el recubrimiento adquiere una estructura cristalina con muy buena adherencia al material del substrato. Se consigue una menor corrosión y mayor

  3. Microstructural characterisation of chromium slags

    Directory of Open Access Journals (Sweden)

    J. Burja

    2015-04-01

    Full Text Available In this chromium slags that form during melting of chromium alloyed steels are examined. During melting and oxidation of these steel grades a considerable amount of chromium is lost, and gained back with slag reduction. Laboratory experiments were performed to study the mechanism of chromium oxide reduction by silicon. Slags chemistry and phase composition have a strong effect on the steelmaking process. Phase analysis revealed two types of chromium oxides, calcium chromites and chromite spinels dependent on chemistry and basicity of the slag.

  4. Biosorption of chromium

    African Journals Online (AJOL)

    Kathiresan

    metal accumulation in the biomass was determined by using an inductively coupled plasma system. (ICP- Optical ... processing time with 30 batch experimental plan derived from the centre composite design (CCD) of .... Central composite design matrix for the experimental design and predicted responses for chromium.

  5. Chromium and aging

    Science.gov (United States)

    Aging is associated with increased blood glucose, insulin, blood lipids, and fat mass, and decreased lean body mass leading to increased incidences of diabetes and cardiovascular diseases. Improved chromium nutrition is associated with improvements in all of these variables. Insulin sensitivity de...

  6. Activated carbons and low cost adsorbents for remediation of tri- and hexavalent chromium from water.

    Science.gov (United States)

    Mohan, Dinesh; Pittman, Charles U

    2006-09-21

    Hexavalent chromium is a well-known highly toxic metal, considered a priority pollutant. Industrial sources of Cr(VI) include leather tanning, cooling tower blowdown, plating, electroplating, anodizing baths, rinse waters, etc. The most common method applied for chromate control is reduction of Cr(VI) to its trivalent form in acid (pH approximately 2.0) and subsequent hydroxide precipitation of Cr(III) by increasing the pH to approximately 9.0-10.0 using lime. Existing overviews of chromium removal only cover selected technologies that have traditionally been used in chromium removal. Far less attention has been paid to adsorption. Herein, we provide the first review article that provides readers an overview of the sorption capacities of commercial developed carbons and other low cost sorbents for chromium remediation. After an overview of chromium contamination is provided, more than 300 papers on chromium remediation using adsorption are discussed to provide recent information about the most widely used adsorbents applied for chromium remediation. Efforts to establish the adsorption mechanisms of Cr(III) and Cr(VI) on various adsorbents are reviewed. Chromium's impact environmental quality, sources of chromium pollution and toxicological/health effects is also briefly introduced. Interpretations of the surface interactions are offered. Particular attention is paid to comparing the sorption efficiency and capacities of commercially available activated carbons to other low cost alternatives, including an extensive table.

  7. The influence of solidification speed during heating on allotropic transformations of chromium cast iron casting

    Directory of Open Access Journals (Sweden)

    M. Przybył

    2008-08-01

    Full Text Available The unique stand to founding dilatometric samples ("on ready” which solidify with different cooling speeds was presented. The dilatometric investigations, X-ray, metallographic they disclosed the occurrence in matrix of chromium cast iron of considerable quantity of austenite in dependence from concentration of chromium (18% and 23% and the speed of solidification. Castings these despite large part of austenite mark with high hardness in raw state.

  8. Hair chromium concentration and chromium excretion in tannery workers.

    Science.gov (United States)

    Saner, G; Yüzbasiyan, V; Cigdem, S

    1984-01-01

    Hair and urine samples were collected from 34 male tannery workers and from 12 normal adults. Eighteen of the workers dealt directly with chromium and the remaining 16 (controls) worked in the offices and kitchen of the same factory. All were found to be clinically healthy. Chromium was determined by flameless atomic absorption spectroscopy. When compared with normal adult values, urinary chromium concentration, Cr/Creatinine ratio, daily chromium excretion, and hair chromium, concentrations were significantly higher and urinary beta 2-microglobulin/Cre ratios significantly lower in both tannery workers and in controls. A significant negative correlation was found between urinary beta 2-microglobulin/Cre and Cr/Cre ratios of tannery workers and controls. A significant positive correlation was shown between hair chromium and urinary Cr/Cre values in all workers. No correlations between the duration of exposure to chromium and hair and urinary chromium values were found. Nevertheless, high values observed in workers with short exposures show that chromium is readily absorbed through the respiratory system. PMID:6372853

  9. Chromium uptake by Fenugreek

    OpenAIRE

    Xanthate D S; Murthy Ch V R; Rajan S C S; Sekhar D M R

    2012-01-01

    Fenugreek (Trigonella foenum- graecum) is both herb (leaves) and a spice (seed) belonging to the family Fabaceae. Fenugreek leaves and seeds are used in the cuisine of India. Fenugreek also has medicinal value. Fenugreek seeds are known to reduce serum glucose and improve glucose tolerance and hence are prescribed to diabetic patients. In the recent past supplemental Chromium is being prescribed to diabetic patients to activate (increased- insulin binding, insulin receptor number, insulin rec...

  10. U.S. Army Toxic Metal Reduction Program: Demonstrating Alternatives to Hexavalent Chromium and Cadmium in Surface Finishing

    Science.gov (United States)

    2014-11-18

    Aluminum conversion coatings* Hard chrome plating* Magnesium anodizing* Sealers and rinses * Stripping of anodizing and platings* Passivation of stainless...steel* Cad Plating Nickel Plating Electroless Nickel Etching *Contains Cr6+ The Long and Winding Road Process Specification Hazardous Chemicals...Cadmium-Free Connectors and Fasteners Cadmium-Free Plating for Components Dichromate-Free Sealers / Primers Cr(VI)-Free Sealants and Adhesives

  11. Performance characteristics of mill rolls from graphite chromium cast iron

    OpenAIRE

    Lecomte-Beckers, Jacqueline; Terziev, L.; Breyer, J. P.

    2000-01-01

    The main requirements for the development of a new grade for the later finishing section of the mill are : good oxidation and thermal behaviour, high wear resistance, good resistance to rolling incidents. The approach of Marichal Ketin to improve the rolling performances in the last finishing stands is presented. The Hi-Cr cast iron possesses excellent wear resistance due to the presence of hard chromium carbides, but its thermal conductivity and sticking properties are fairly low. A graphite...

  12. Cold plate

    Energy Technology Data Exchange (ETDEWEB)

    Marroquin, Christopher M.; O' Connell, Kevin M.; Schultz, Mark D.; Tian, Shurong

    2018-02-13

    A cold plate, an electronic assembly including a cold plate, and a method for forming a cold plate are provided. The cold plate includes an interface plate and an opposing plate that form a plenum. The cold plate includes a plurality of active areas arranged for alignment over respective heat generating portions of an electronic assembly, and non-active areas between the active areas. A cooling fluid flows through the plenum. The plenum, at the non-active areas, has a reduced width and/or reduced height relative to the plenum at the active areas. The reduced width and/or height of the plenum, and exterior dimensions of cold plate, at the non-active areas allow the non-active areas to flex to accommodate surface variations of the electronics assembly. The reduced width and/or height non-active areas can be specifically shaped to fit between physical features of the electronics assembly.

  13. 76 FR 35806 - Amendments to National Emission Standards for Hazardous Air Pollutants for Area Sources: Plating...

    Science.gov (United States)

    2011-06-20

    ..., or Use I. National Technology Transfer Advancement Act J. Executive Order 12898: Federal Actions To... From Hard and Decorative Chromium Electroplating and Chromium Anodizing Tanks.'' Manufacturing 32,33..., Hardware Manufacturing; 323111, Commercial Gravure Printing; 332116, Metal Stamping; 332722, Bolt, Nut...

  14. Chromium mobility in freshwater wetlands

    Science.gov (United States)

    Mattuck, Rosemary; Nikolaidis, Nikolaos P.

    1996-07-01

    A wetland at a chromium-contaminated electroplating site was studied to determine its ability to immobilize subsurface chromium contamination. First, a site characterization was conducted to determine the lateral and vertical extent of chromium contamination in the sediment and pore water. The wetland was found to be highly contaminated, with sediment concentrations of up to 50,000 μg g -1. Chromium was partitioned largely on the sediment, with Kd's up to 317,000 mL g -1. No Cr(VI) was detected in the pore water. Sequential chemical extractions performed on the sediment found 60-90% of the chromium bound in the {Fe}/{Mn}- oxide and residual fractions of the soil, with very little exchangeable or organic-bound chromium present. These results indicate that the chromium is very tightly bound to the sediment. XPS determined a very low {Cr}/{Si} ratio on the solid surface. Batch leaching experiments using the contaminated sediment were conducted at pH 3, 4, and 5. Leaching of chromium from the sediment increased with lower pH, ranging from 0.02% to 0.34% of the total, and appeared to be solubility controlled. Results indicate that the wetland has been highly effective in immobilizing Cr, by reducing the Cr(VI) and precipitating it as a relatively insoluble Cr(III)-hydroxide.

  15. Standard hardness conversion tables for metals relationship among brinell hardness, vickers hardness, rockwell hardness, superficial hardness, knoop hardness, and scleroscope hardness

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 Conversion Table 1 presents data in the Rockwell C hardness range on the relationship among Brinell hardness, Vickers hardness, Rockwell hardness, Rockwell superficial hardness, Knoop hardness, and Scleroscope hardness of non-austenitic steels including carbon, alloy, and tool steels in the as-forged, annealed, normalized, and quenched and tempered conditions provided that they are homogeneous. 1.2 Conversion Table 2 presents data in the Rockwell B hardness range on the relationship among Brinell hardness, Vickers hardness, Rockwell hardness, Rockwell superficial hardness, Knoop hardness, and Scleroscope hardness of non-austenitic steels including carbon, alloy, and tool steels in the as-forged, annealed, normalized, and quenched and tempered conditions provided that they are homogeneous. 1.3 Conversion Table 3 presents data on the relationship among Brinell hardness, Vickers hardness, Rockwell hardness, Rockwell superficial hardness, and Knoop hardness of nickel and high-nickel alloys (nickel content o...

  16. Influence of a cobalt-chromium metal framework on surface roughness and Knoop hardness of visible light-polymerized acrylic resins Influência de estrutura metálica de cobalto-cromo na rugosidade e dureza Knoop superficiais de resinas acrílicas polimerizadas por luz visível

    Directory of Open Access Journals (Sweden)

    Joane Augusto de Souza Júnior

    2006-06-01

    Full Text Available Although visible light-polymerized acrylic resins have been used in removable partial dentures, it is not clear whether the presence of a metal framework could interfere with their polymerization, by possibly reflecting the light and affecting important properties, such as roughness and hardness, which would consequently increase biofilm accumulation. The aim of this study was to compare the roughness and Knoop hardness of a visible light-polymerized acrylic resin and to compare these values to those of water-bath- and microwave-polymerized resins, in the presence of a metal framework. Thirty-six specimens measuring 30.0 x 4.0 ± 0.5 mm of a microwave- (Onda Cryl, a visible light- (Triad and a water-bath-polymerized (Clássico (control acrylic resins containing a cobalt-chromium metal bar were prepared. After processing, specimens were ground with 360 to 1000-grit abrasive papers in a polishing machine, followed by polishing with cloths and 1-µm diamond particle suspension. Roughness was evaluated using a profilometer (Surfcorder SE 1700 and Knoop hardness (Kg/mm² was assayed using a microhardness tester (Shimadzu HMV 2000 at distances of 50, 100, 200, 400 and 800 µm from the metal bar. Roughness and Knoop hardness means were submitted to two-way ANOVA and compared by Tukey and Kruskal Wallis tests at a 5% significance level Statistically significant differences were found (p0.05. Within the limitations of this in vitro study, it was concluded that the presence of metal did not influence roughness and hardness values of any of the tested acrylic resins.Resinas acrílicas polimerizadas por luz visível têm sido indicadas para a confecção de próteses parciais removíveis. Entretanto, não há estudos determinando se a presença de estrutura metálica interfere ou não na polimerização, considerando que essa estrutura pode refletir a luz e afetar propriedades como rugosidade e dureza e, consequentemente, facilitar o acúmulo de biofilme

  17. Groundwater contaminant by hexavalent chromium

    Energy Technology Data Exchange (ETDEWEB)

    Parsons, C. [Univ. of Texas, Austin, TX (United States)

    1995-11-01

    Oxidation of trivalent chromium to hexavalent chromium has been investigated as a function of total manganese in soils as well as various incubation conditions. Chromium and manganese contents were analyzed by atomic absorption (graphite furnace and flame emission respectively) following acid digestion. Total hexavalent chromium generation capacity was determined by addition of 0.001 M CrCL3, incubation, and analysis by s-diphenyl carbazide. Samples were then leached with CaSO{sub 4} and MgSO{sub 4} and incubated in various environments (oven, freeze-drier, field moist, ultrafreeze) to test for geogenic generation of Cr(IV). The degree of geogenic generation of hexavalent chromium was compared with total Mn and Cr content as well as hexavalent generational capacity.

  18. Role of paramagnetic chromium in chromium(VI)-induced damage in cultured mammalian cells.

    OpenAIRE

    Sugiyama, M

    1994-01-01

    Chromium(VI) compounds are known to be potent toxic and carcinogenic agents. Because chromium(VI) is easily taken up by cells and is subsequently reduced to chromium(III), the formation of paramagnetic chromium such as chromium(V) and chromium(III) is believed to play a role in the adverse biological effects of chromium(VI) compounds. The present report, uses electron spin resonance (ESR) spectroscopy; the importance of the role of paramagnetic chromium in chromium(VI)-induced damage in intac...

  19. REMOVAL OF HEXAVALENT CHROMIUM FROM AQUEOUS ...

    African Journals Online (AJOL)

    a

    Also, acute systemic poisoning can result from high exposure to hexavalent chromium [2]. Most of the chromium ions in wastewater especially hexavalent chromium originates from industries such as electroplating, metal finishing and magnetic tape manufacturing. For these industrial groups, chromium is a problematic one.

  20. 29 CFR 1926.1126 - Chromium (VI).

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Chromium (VI). 1926.1126 Section 1926.1126 Labor... Chromium (VI). (a) Scope. (1) This standard applies to occupational exposures to chromium (VI) in all forms... objective data demonstrating that a material containing chromium or a specific process, operation, or...

  1. 29 CFR 1915.1026 - Chromium (VI).

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Chromium (VI). 1915.1026 Section 1915.1026 Labor... § 1915.1026 Chromium (VI). (a) Scope. (1) This standard applies to occupational exposures to chromium (VI... cement; or (4) Where the employer has objective data demonstrating that a material containing chromium or...

  2. Study of the Microstructure Evolution and Properties Response of a Friction-Stir-Welded Copper-Chromium-Zirconium Alloy

    Directory of Open Access Journals (Sweden)

    Ruilin Lai

    2017-09-01

    Full Text Available In this article, the copper-chromium-zirconium (CuCrZr alloys plates with 21 mm in thickness were butt joined together by means of FSW (friction stir welding. The properties of the FSW joints are studied. The microstructure variations during the process of FSW were investigated by optical microscopy (OM, electron back-scattered diffraction (EBSD, and transmission electron microscopy (TEM. The results show that the grains size in the nugget zone (NZ are significantly refined, which can be attributed to the dynamic recrystallization (DRX. The microstructure distribution in the NZ is inhomogeneous and the size of equiaxed grains are decreased gradually along the thickness direction from the top to bottom area of the welds. Meanwhile, it is found that the micro-hardness and tensile strength of the welds are slightly increased along the thickness direction from the top to the bottom area of the welds. All the nano-strengthening precipitates in the BM are dissolved into the Cu matrix in the NZ. Therefore, the decreases in hardness, tensile strength, and electrical conductivity can be attributed to the comprehensive effect of dissolution of nano-strengthening precipitates into the supersaturation matrix and severe DRX in the welded NZ.

  3. Release of Chromium from Orthopaedic Arthroplasties

    OpenAIRE

    Afolaranmi, G.A.; Tettey, J; Meek, R. M. D; Grant, M. H.

    2008-01-01

    Many orthopaedic implants are composed of alloys containing chromium. Of particular relevance is the increasing number of Cobalt Chromium bearing arthroplasies being inserted into young patients with osteoarthritis. Such implants will release chromium ions. These patients will be exposed to the released chromium for over 50 years in some cases. The subsequent chromium ion metabolism and redistribution in fluid and tissue compartments is complex. In addition, the potential biological effects o...

  4. Chromium isotope variations

    DEFF Research Database (Denmark)

    D'Arcy, Joan Mary

    Chromium (Cr) stable isotopes are a useful tracer of changes in redox conditions because changes in its oxidation state are accompanied by an isotopic fractionation. For this reason the Cr isotope system is being developed as a potential tool for paleo-redox reconstruction. Dissolved Cr in seawater...... is incorporated into carbonates. Hence, ancient carbonates can potentially record the Cr isotopic composition (δ53Cr ‰) of seawater in the geological past. Reliable application and interpretation of this proxy requires a detailed knowledge about processes that fractionate Cr on the Earth’s surface......, and the quantification the Cr isotope composition of major Cr fluxes into and out of ocean. This thesis adds to the current knowledge of the Cr isotope system and is divided into two studies. The focus of the first study was to determine what processes control the Cr isotopic compositionof river water and to quantify...

  5. Polypropylene microtitre plates modified with [Cr(OH)6](3-) for enhanced ELISA sensitivity.

    Science.gov (United States)

    Welch, Nicholas G; Lebot, Cedric J; Easton, Christopher D; Scoble, Judith A; Pigram, Paul J; Muir, Benjamin W

    2017-07-01

    Chromium solutions have been used as wet chemical modifiers for polymer microtitre plates used in improving immunoassay performance. However, polypropylene has been excluded from the list of potentially modifiable substrates (AnteoTechnologies, 2015). Here we show that untreated polypropylene microtitre plates can indeed be modified using a [Cr(OH)6](3-) complex. Compared to unmodified polypropylene, the chromium modified surfaces demonstrate an up to 4-fold improvement in both assay sensitivity and signal intensity in an antigen capture ELISA. Atomic force microscope (AFM) images indicate that the chromium complex facilitates dispersion of the antibody, reducing aggregation. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. The Abrasive Wear Resistance of Chromium Cast Iron

    Directory of Open Access Journals (Sweden)

    Kopyciński D.

    2014-03-01

    Full Text Available The resistance of cast iron to abrasive wear depends on the metal abrasive hardness ratio. For example, hardness of the structural constituents of the cast iron metal matrix is lower than the hardness of ordinary silica sand. Also cementite, the basic component of unalloyed white cast iron, has hardness lower than the hardness of silica. Some resistance to the abrasive effect of the aforementioned silica sand can provide the chromium white cast iron containing in its structure a large amount of (Cr, Fe7C3 carbides characterised by hardness higher than the hardness of the silica sand in question. In the present study, it has been anticipated that the white cast iron structure will be changed by changing the type of metal matrix and the type of carbides present in this matrix, which will greatly expand the application area of castings under the harsh operating conditions of abrasive wear. Moreover, the study compares the results of abrasive wear resistance tests performed on the examined types of cast iron. Tests of abrasive wear resistance were carried out on a Miller machine. Samples of standard dimensions were exposed to abrasion in a double to-and-fro movement, sliding against the bottom of a trough filled with an aqueous abrasive mixture containing SiC + distilled water. The obtained results of changes in the sample weight were approximated with a power curve and shown further in the study.

  7. Structure and characteristics of chromium steel coatings alloyed with boron carbide

    Science.gov (United States)

    Eremin, E. N.; Losev, A. S.; Borodikhin, S. A.; Matalasova, A. E.; Ponomarev, I. A.; Ivlev, K. E.

    2018-01-01

    This study explores the problems arising from the increase of wear resistance on the coatings of details of a wide range of applications, obtained by surfacing the Fe - Cr system with flux-cored wires. It has shown that insignificant wear resistance of such steel under conditions of metal friction against another metal is due to their relatively low hardness and the absence of strengthening phases. It also shows the effect of boron carbide on the structure and the characteristics of chromium steel obtained by the surfacing process. It was established that the use of high-chromium flux-cored wires alloyed with boron carbide aids the production of a deposited metal of a composite type, with a dispersed hardening based on chromium carboboride. The deposited metal with such structure has a high wear resistance and the hardness of 55 … 58 HRC and can be used for surfacing cladding the hardening, corrosion-resistant coatings.

  8. Chromium-induced kidney disease.

    OpenAIRE

    Wedeen, R P; Qian, L F

    1991-01-01

    Kidney disease is often cited as one of the adverse effects of chromium, yet chronic renal disease due to occupational or environmental exposure to chromium has not yet been reported. Occasional cases of acute tubular necrosis (ATN) following massive absorption of chromate have been described. Chromate-induced ATN has been extensively studied in experimental animals following parenteral administration of large doses of potassium chromate (hexavalent) (15 mg/kg body weight). The chromate is se...

  9. Plate tectonics

    Digital Repository Service at National Institute of Oceanography (India)

    Chaubey, A.K.

    Content-Type text/plain; charset=UTF-8 209 Plate Tectonics A. K. Chaubey National Institute of Oceanography, Dona Paula, Goa-403 004. chaubey@nio.org Introduction The theory of continental drift, which paved the way for discovery... of plate tectonics, was put forward by Alfred Lother Wegener - a meteorologist from Germany - in 1912. The theory states that continents are not fixed, but have been slowly wandering during the course of Earth’s geological history. Although Wegener...

  10. Acute Severe Chromium Poisoning After Dermal Exposure to Hexavalent Chromium

    Directory of Open Access Journals (Sweden)

    Chun-Chi Lin

    2009-04-01

    Full Text Available Severe acute chromium poisoning related to dermal involvement has rarely been reported in the literature. We report a case of acute severe chromium poisoning through skin exposure as a result of a chemical burn of 15% of the body surface area and multiple organ failure after short-term exposure. Medical interventions, including mechanical ventilation, continuous venovenous hemofiltration, and plasmapheresis were performed. In addition, a chelating agent, dimercapto-propane sulfonic acid, was infused intravenously, combined with intravenous N-acetylcysteine and ascorbic acid as adjuvant therapy. The patient was discharged on day 33 without long-term sequelae. The consequence of transdermal exposure of hexavalent chromium should not be overlooked.

  11. Chromium-induced kidney disease

    Energy Technology Data Exchange (ETDEWEB)

    Wedeen, R.P. (VA Medical Center, East Orange, NJ (United States)); Qian, Lifen (New Jersey Medical School, Newark (United States))

    1991-05-01

    Kidney disease is often cited as one of the adverse effects of chromium, yet chronic renal disease due to occupational or environmental exposure to chromium has not been reported. Occasional cases of acute tubular necrosis (ATN) following massive absorption of chromate have been described. Chromate-induced ATN has been extensively studied in experimental animals following parenteral administration of large doses of potassium chromate (hexavalent). The chromate is selectively accumulated in the convoluted proximal tubule where necrosis occurs. An adverse long-term effect of low-dose chromium exposure on the kidneys is suggested by reports of low molecular weight (LMW) proteinuria in chromium workers. Excessive urinary excretion of {beta}{sub 2}-microglobulin, a specific proximal tubule brush border protein, and retinol-binding protein has been reported among chrome palters and welders. However, LMW proteinuria occurs after a variety of physiologic stresses, is usually reversible, and cannot by itself be considered evidence of chromic renal disease. Chromate-induced ATN and LMW proteinuria in chromium workers, nevertheless, raise the possibility that low-level, long-term exposure may produce persistent renal injury. The absence of evidence of chromate-induced chromic renal disease cannot be interpreted as evidence of the absence of such injury.

  12. Chromium removal from aqueous media by superparamagnetic ...

    Indian Academy of Sciences (India)

    the superparamagnetic starch functionalized maghemite nano-adsorbents is spontaneous and endothermic in nature. Keywords. Chromium removal; starch; maghemite nanoparticles; adsorption. 1. Introduction. Industrial wastewater often contains substantial amount of hexavalent chromium mainly from rinsing of electro-.

  13. Chromium Uptake Efficiency of Spinacea olaracea from ...

    African Journals Online (AJOL)

    The aim of the study was to evaluate the uptake of chromium by Spinacea olaracea and its accumulation in roots and shoots of plants grown in pots at various concentrations of chromium (30, 60, 90,120,150 mg/l). The results revealed that the levels of chromium accumulation in roots and shoots were higher at minimum ...

  14. Pulse reversal plating of nickel alloys

    DEFF Research Database (Denmark)

    Tang, Peter Torben

    2007-01-01

    Pulse plating has previously been reported to improve the properties of nickel and nickel alloy deposits. Typically, focus has been on properties such as grain size, hardness and smoothness. When pulse plating is to be utilised for microtechnologies such as microelectromechanical systems (MEMS......), internal stress and material distribution are even more important. With baths based upon nickel chloride, and nickel and cobalt chlorides, pulse reversal plating of both pure nickel and nickel-cobalt alloys has been used to fabricate tools for microinjection moulding. Pulse reversal plating of ternary soft...

  15. Biosorption of hexavalent chromium (chromium (VI) ion from ...

    African Journals Online (AJOL)

    taye

    2015-04-01

    Apr 1, 2015 ... An experimental effluent analysis was conducted in conjunction with bioremediation process from ... Hexavalent Chromium (Cr (VI) is a by-product released .... Agriculture waste either saw dust or rice husk was procured from. Sabon Gari market, Zaria, Nigeria and brought to the Laboratory for analysis.

  16. Chromium(III) -- chromium(VI) interconversions in seawater

    NARCIS (Netherlands)

    Weijden, C.H. van der; Reith, M.

    1982-01-01

    The stable form of dissolved chromium in oxygenated seawater is Cr(VI). But Cr(III)-species are also present at an analytically significant level. It is shown that Cr(III) is oxidized only slowly by dissolved oxygen, and that manganese oxide is a strong catalyst for such oxidation. However, the low

  17. Improved Electrodeposited Low Contraction Chromium.

    Science.gov (United States)

    1982-04-01

    and during testing, special fix- tures were devised to grip the brittle chromium tubes. PVC end caps were 2 ~7 . -~Z machined to accommodate the...LC 1 REDSTONE ARSENAL, AL 35898 - LCA (PLASTICS TECH 1 EVAL CEN) COMMANDER -LCE 1 REDSTONE ARSENAL -LCM I ATTN: DRSMI-RRS I -LCS 1 -RSM 1 -LCW 1

  18. Chromium Salen Mediated Alkene Epoxidation

    DEFF Research Database (Denmark)

    Petersen, Kaare Brandt; Norrby, Per-Ola; Daly, Adrian M.

    2002-01-01

    The mechanism of alkene epoxidation by chromium(v) oxo salen complexes has been studied by DFT and experimental methods. The reaction is compared to the closely related Mn-catalyzed process in an attempt to understand the dramatic difference in selectivity between the two systems. Overall, the st...

  19. Remediation of soils contaminated with chromium using citric and hydrochloric acids: the role of chromium fractionation in chromium leaching.

    Science.gov (United States)

    Cheng, Shu-Fen; Huang, Chin-Yuan; Tu, Yao-Ting

    2011-01-01

    Acid washing is a common method for soil remediation, but is not always efficient for chromium-contaminated soil. Both soil particle size and the forms of chromium existing in the soil affect the efficiency of soil washing. Laboratory batch and column dissolution experiments were conducted to determine the efficiencies of citric and hydrochloric acids as agents to extract chromium from soils contaminated with chromium. The effects of soil particle size and chromium fractionation on Cr leaching were also investigated. About 90% of chromium in the studied soil existed either in residual form or bound to iron and manganese oxides, and Cr fraction distributions were similar for all soil particle sizes. Almost all exchangeable and carbonate-bound chromium was removed by washing once with 0.5 M HCl, whereas organic chromium was more effectively removed by washing with citric acid rather than with HCl solution of the same concentration. For chromium fractions that were either bound to Fe-Mn oxides or existed as residual forms, the efficiencies of acid washing were usually 20% or less, except for 0.5 M HCl solution, which had much higher efficiencies. Separation of the soil sample by particle size before the separate washing of the soil fractions had little improvement on the chromium removal.

  20. Isolation of Electrogenic Microorganisms with Potential to Reduce Hexavalent Chromium

    Directory of Open Access Journals (Sweden)

    Alexander Mora Collazos

    2017-01-01

    Full Text Available Isolation of cultivable microorganisms was made from the biofilm formed on the anode of a microbial fuel cell put into operation for 30 days; isolated microorganisms were evaluated for their ability to produce energy and reduce the hexavalent chromium Cr (VI. Five microorganisms were isolated, which were characterized by analysis of 16S rRNA gene, placing them in four bacterial genera: Exiguobacterium (CrMFC1, Acinetobacter (CrMFC2, Aeromonas (CrMFC3 and CrMFC5 and Serratia (CrMFC4. All isolates showed electrogenic activity and ability to reduce hexavalent chromium; the Acinetobacter CrMFC1 strain showed the best electrochemical performance registering a maximum power density of 18.61 mW/m2; the other strains showed values of maximum power density between 4.6 mW/m2and 7.1 mW/m2. Strains Aeromonas CrMFC5 and Exiguobacterium CrMFC1 showed the best rates of chromium reduction being able to reduce 100 % of the Cr (VI in less than 24 hours, the Aeromonas CrMFC5 strain was the most efficient, reducing 100 % of Cr (VI in 10 hours; the other strains reduced 100% of the contaminant after 28 to 30 hours. The microorganisms isolated in this study are hardly known for their electrogenic capacity and for reducing Cr (VI; however, show promise for their use in combined systems involving energy production system coupled to bioremediation of chromium contaminated water.

  1. Recovery and reuse of hexavalent chromium from aqueous solutions by a hybrid technique of electrodialysis and ion exchange

    Directory of Open Access Journals (Sweden)

    R. Gayathri

    2010-03-01

    Full Text Available The chrome plating industry is one of the highly polluting industries whose effluent mainly consists of chromium(VI. This compound is highly toxic to aquatic life and human health. The rinse water constituents reflect the chrome plating bath characteristics; generally dead tank wash water contains about 1% of the plating bath concentration. Other metals and metal compounds usually considered as toxic can be precipitated out by suitably adjusting the pH of the wastewaters. However, Cr(VI is soluble in almost all pH ranges and therefore an efficient treatment is required for the removal and recovery of chromium, and also for the reuse of wastewaters. The present study aims to recover the chromium by a hybrid technique of electrodialysis and ion exchange for the removal and concentration of chromate ions from the effluent. The different modes of operation like batch recirculation process, batch recirculation process with continuous dipping and continuous process were carried out to remove and recover the chromium from the effluent and the percentage reductions of chromium were found to be 98.69%, 99.18% and 100%, respectively.

  2. Chromium speciation in solid matrices and regulation: a review

    Energy Technology Data Exchange (ETDEWEB)

    Unceta, N. [University of the Basque Country, Department of Analytical Chemistry, Faculty of Pharmacy, Vitoria-Gasteiz (Spain); Seby, F. [Ultra Traces Analyses Aquitaine (UT2A), Helioparc Pau-Pyrenees, Pau (France); Malherbe, J.; Donard, O.F.X. [Universite de Pau et des Pays de l' Adour, Helioparc Pau-Pyrenees, Laboratoire de Chimie Analytique Bio-Inorganique et Environnement, IPREM, UMR CNRS 5254, Pau (France)

    2010-06-15

    In recent years, the extensive use of chromium in industrial processes has led to the promotion of several directives and recommendations by the European Union, that try to limit and regulate the presence of Cr(VI) in the environment and to protect industrial workers using chromium and end-users of manufactured products. As a consequence, new standard methods and analytical procedures have been published at the EU level for Cr(VI) determination in soil, sludge, sediment, and similar waste materials, workplace atmospheres, cement, packaging materials, industrially produced samples, and corrosion-protection layers on some components of vehicles and electrical and electronic equipment. The objective of this article is to summarize the different directives and recommendations and to critically review the currently existing standard methods and the methods published in the literature for chromium speciation in the above mentioned solid matrices, putting the emphasis on the different extraction procedures which have been developed for each matrix. Particular attention has been paid to Cr(III) and Cr(VI) inter-conversions that can occur during extraction and efforts to minimize these unwanted reactions. Although the use of NaOH-Na{sub 2}CO{sub 3} solutions with hot plate extraction seems to be the more widespread procedure, species transformation can still occur and several studies suggest that speciated isotope-dilution mass spectrometry (SIDMS) could be a suitable tool for correction of these interconversions. Besides, recent studies have proved the role of Cr(III) in chromium toxicology. As a consequence, the authors suggest an update of standard methods in the near future. (orig.)

  3. Responses of endogenous proline in rice seedlings under chromium exposure

    Directory of Open Access Journals (Sweden)

    X.Z. Yu

    2016-12-01

    Full Text Available Hydroponic experiments were performed to exam the dynamic change of endogenous proline in rice seedlings exposed to potassium chromate chromium (VI or chromium nitrate chromium (III. Although accumulation of both chromium species in rice seedlings was obvious, more chromium was detected in plant tissues of rice seedlings exposed to chromium (III than those in chromium (VI, majority being in roots rather than shoots. Results also showed that the accumulation capacity of chromium by rice seedlings was positively correlated to chromium concentrations supplied in both chromium variants and the accumulation curve depicted an exponential trend in both chromium treatments over the entire period of exposure. Proline assays showed that both chromium variants induced the change of endogenous proline in shoots and roots of rice seedlings. Chromium (VI of 12.8 mg/L increased proline content significantly (p

  4. Study of hematological indices in tannery workers exposed to chromium in Sheikhupura (Pakistan).

    Science.gov (United States)

    Ramzan, Muhammad; Malik, Muhammad Anwar; Iqbal, Zaheer; Arshad, Najma; Khan, Shafaat Yar; Arshad, Muhammad

    2011-10-01

    Chromium (Cr), being an excellent tanning agent, is widely used in the leather industry and tannery workers (TW) are exposed to it either in the form of inorganic Cr(III) compounds or Cr bound to proteins (leather dust) in the process of leather production. During the present study, the effect of Cr on the hematological indices in TW was evaluated. In this study, hematological indices of 92 male TW aged 20-60 years were compared with 79 control males who hardly had a chance of exposure to chromium. Both groups were subdivided into four age groups with an interval of 10: group A, 20-29 years; group B, 30-39 years; group C, 40-49 years; group D, 50-60 years. Total erythrocyte count (TEC) was significantly lower (p tannery workers and may act as indicators of chromium toxicity.

  5. Enhanced magnetorheological response of magnetic chromium dioxide nanoparticle added carbonyl iron suspension

    Science.gov (United States)

    Kim, Min Hwan; Choi, Kisuk; Do Nam, Jae; Choi, Hyoung Jin

    2017-09-01

    Hard-magnetic chromium dioxide nanoparticles with a rod-like shape were introduced as an additive to a soft-magnetic carbonyl iron (CI)-based magnetorheological (MR) fluid. The magnetic stimuli-response of the MR fluid in terms of the steady shear and dynamic oscillation tests was examined using a rotational rheometer. While the Bingham fluid model fitted the flow curves, the dynamic yield stress followed the universal yield stress scale function quite well. Compared to the CI-based MR fluid without chromium dioxide nanoparticles, the MR fluid with the chromium dioxide additive exhibited remarkably higher yield behavior with increasing magnetic field strength, enhancing its MR performance and dispersion stability.

  6. Reduction of Hexavalent Chromium Using Sorbaria sorbifolia Aqueous Leaf Extract

    Directory of Open Access Journals (Sweden)

    Shashi Prabha Dubey

    2017-07-01

    Full Text Available Aqueous plant leaves extract (PLE of an abundant shrub, Sorbaria sorbifolia, was explored for the reduction of hexavalent chromium, Cr(VI, to trivalent chromium, Cr(III. The effect of contact time, pH, PLE quantity, ionic strength, hardness, temperature and effective initial Cr(VI ion concentration were tested; Cr(VI reduction followed the pseudo-first order rate kinetics and maximum reduction was observed at pH 2. Significantly, Cr(VI reduction efficacies varied from 97 to 66% over the pH range of 2 to 10, which bodes well for PLE to be used for the reduction of Cr(VI also at a higher pH. PLE-mediated Cr(VI reduction displays considerable efficiency at various ionic strengths; however, hardness strongly affects the reduction ability. Higher temperature significantly enhances the Cr(VI reduction. This study reveals the potential use of PLE as a green reducing agent in aqueous extract for the efficient reduction of Cr(VI to Cr(III.

  7. Precipitation of metallic chromium during rapid cooling of Cr2O3 slags

    Directory of Open Access Journals (Sweden)

    J. Burja

    2017-01-01

    Full Text Available The slag systems of CaO-SiO2- Cr2O3 and Al2O3-CaO-MgO-SiO2- Cr2O3 were analyzed. These slag systems occur in the production of stainless steel and are important from the process metallurgy point of view. Synthetic slag samples with different chromium oxide content were prepared and melted. The melted slag samples where then rapidly cooled on large steel plates, so that the high temperature microstructure was preserved. The samples were analyzed by scanning electron microscopy (SEM and X-ray diffraction (XRD. The precipitation of different chromium oxide phases was studied, but most importantly the precipitation of metallic chromium was observed. These findings help us interpret industrial slag samples.

  8. Create Your Plate

    Medline Plus

    Full Text Available ... A A A Listen En Español Create Your Plate Create Your Plate is a simple and effective ... and that your options are endless. Create Your Plate! Click on the plate sections below to add ...

  9. Simultaneous determination of chromium(III) and chromium(VI) in aqueous solutions by ion chromatography and chemiluminescence detection

    DEFF Research Database (Denmark)

    Gammelgaard, Bente; Jøns, O; Nielsen, B

    1992-01-01

    A method for the simultaneous determination of chromium(iii) and chromium(vi) in a flow system based on chemiluminescence was developed. A Dionex cation-exchange guard column was used to separate chromium(iii) from chromium(vi), and chromium(vi) was reduced by potassium sulfite, whereupon both...

  10. Thermodynamic hardness and the maximum hardness principle

    Science.gov (United States)

    Franco-Pérez, Marco; Gázquez, José L.; Ayers, Paul W.; Vela, Alberto

    2017-08-01

    An alternative definition of hardness (called the thermodynamic hardness) within the grand canonical ensemble formalism is proposed in terms of the partial derivative of the electronic chemical potential with respect to the thermodynamic chemical potential of the reservoir, keeping the temperature and the external potential constant. This temperature dependent definition may be interpreted as a measure of the propensity of a system to go through a charge transfer process when it interacts with other species, and thus it keeps the philosophy of the original definition. When the derivative is expressed in terms of the three-state ensemble model, in the regime of low temperatures and up to temperatures of chemical interest, one finds that for zero fractional charge, the thermodynamic hardness is proportional to T-1(I -A ) , where I is the first ionization potential, A is the electron affinity, and T is the temperature. However, the thermodynamic hardness is nearly zero when the fractional charge is different from zero. Thus, through the present definition, one avoids the presence of the Dirac delta function. We show that the chemical hardness defined in this way provides meaningful and discernible information about the hardness properties of a chemical species exhibiting integer or a fractional average number of electrons, and this analysis allowed us to establish a link between the maximum possible value of the hardness here defined, with the minimum softness principle, showing that both principles are related to minimum fractional charge and maximum stability conditions.

  11. The Identity of "Chromium Malate".

    Science.gov (United States)

    Smart, Megan; Brown, Silas; Tannehill, Haley; Lockart, Molly; Bowman, Michael K; Vincent, John B

    2017-05-18

    Recently, several studies on the effects of a compound named "chromium malate," with the proposed formula "Cr2malate3·xH2O" where x = 3.5 or 5, on the health of healthy and diabetic rats have appeared. However, the compound is poorly characterized, and knowing the identity of this material could be important in the interpretation of the previous and of future studies on the effects of this compound in animals. Consequently, the synthesis, characterization, and identity of this material were explored. A combination of spectroscopic, magnetic, and elemental analyses and mass spectral studies reveal that the compound is probably a polymer, not a discrete molecule, and does not have the composition previously reported. The repeating unit of the polymer possesses an antiferromagnetically coupled trinuclear Cr(III) core. The current study suggests that previous reports on chromium malate and its effects in animals must be viewed with caution.

  12. Hexavalent chromium [Cr(VI)] removal by the electrochemical ion-exchange process.

    Science.gov (United States)

    Dharnaik, Amit Shivputra; Ghosh, Pranab Kumar

    2014-01-01

    In the present investigation, the performance of a laboratory-scale plate and frame-type electrochemical ion-exchange (EIX) cell on removal ofhexavalent chromium from synthetic wastewater containing 5 mg/l of Cr(VI) was evaluated under varying applied voltages. Ruthenium dioxide-coated titanium plate (RuO2/Ti) was used as anode and stainless steel plates as cathode. The EIX cell was run at different hydraulic retention time (HRT). Before using in the electrochemical cell, the capacity of ion-exchange resin was evaluated through kinetic and isotherm equilibrium tests in batch mode. The batch kinetic study result showed that the equilibrium time for effective ion exchange with resin is 2 h. The isotherm equilibrium data fit well to both Freundlich and Langmuir isotherms. Maximum capacity (qm) of resin calculated from Langmuir isotherm was 71.42 mg/g. Up to 99% of chromium removal was noticed in the EIX cell containing fresh resin at applied voltages of 10 V and higher. Migration of chromium ion to anode chamber was not noticed while performing the experiment with fresh resin. As high as 50% removal of chromium was observed from the middle chamber containing exhausted resin at an applied voltage of 25 V when the influent flow rate was maintained at 45 min of HRT. The performance of the reactor was increased to 72% when the influent flow rate was decreased to maintain at 90 min of HRT. Build-up of chromium in the anode chamber took place when exhausted resin was used in the process.

  13. Analysis on the stability of chromium in mineral phases in stainless steel slag

    Science.gov (United States)

    Cao, Long-hu; Liu, Cheng-jun; Zhao, Qing; Jiang, Mao-fa

    2017-11-01

    Stainless steel slag from high alloy steel is hardly used in the construction industry. The chromium leaching in unstable phase is the limiting factor for the application in the slag. The aim of this study is to investigate the stability of mineral phases in stainless steel slag. In this work, the mineral phases were firstly confirmed through experimental results by SEM-EDS and XRD. Thermodynamic calculation and leaching test were adopted to characterize the theoretical stability of mineral phases in aqueous solution. The results showed that the main phases in the stainless steel slag were spinel, melilite [solid solution of gehlenite (Ca2Al2SiO7) and akermanite (Ca2MgSi2O7)], dicalcium silicate, merwinite and periclase phases. It can be concluded that the minerals behave differently when dissolving in aqueous solution and the dissolution of dicalcium silicate (Ca2SiO4), merwinite (Ca3MgSi2O8), akermanite (Ca2MgSi2O7) and periclase phase could be generally higher, especially at lower pH values. In addition, the solubility of chromium in the spinel phase is considered low. The leaching test demonstrated that the formation of spinel phase can limit the leaching of chromium and the chromium existing in the silicate and periclase phases can facilitate the chromium leaching.

  14. Inoculation of chromium white cast iron

    OpenAIRE

    D. Kopyciński

    2009-01-01

    It has been proved that an addition of boron carbide introduced as an inoculant to the chromium white cast iron changes the structureof castings. Castings after inoculation revealed a different structure with numerous grains. Primary precipitates of chromium carbide also appeared, reducing the mechanical properties of as-cast parts. Properly established heat treatment regime makes chromium iron castings regain their, originally high, mechanical properties.

  15. Inoculation of chromium white cast iron

    Directory of Open Access Journals (Sweden)

    D. Kopyciński

    2009-01-01

    Full Text Available It has been proved that an addition of boron carbide introduced as an inoculant to the chromium white cast iron changes the structureof castings. Castings after inoculation revealed a different structure with numerous grains. Primary precipitates of chromium carbide also appeared, reducing the mechanical properties of as-cast parts. Properly established heat treatment regime makes chromium iron castings regain their, originally high, mechanical properties.

  16. Rad Hard Active Media For Calorimeters

    CERN Document Server

    Norbeck, E; Möller, A; Onel, Y

    2006-01-01

    Zero-degree calorimeters have limited space and extreme levels of radiation. A simple, low cost, radiation hard design uses tungstenmetal as the absorber and a suitable liquid as the ˇCerenkov radiator. In other applications a PPAC (Parallel Plate Avalanche Counter) operatingwith a suitable atmosphericpressure gas is an attractive active material for a calorimeter. It can be made radiation hard and has sufficient gain in the gas that no electronic components are needed near the detector. It works well even with the highest concentration of shower particles. For this pressure range, R134A (used in auto air conditioners) has many desirable features.

  17. Surface modified stainless steels for PEM fuel cell bipolar plates

    Science.gov (United States)

    Brady, Michael P [Oak Ridge, TN; Wang, Heli [Littleton, CO; Turner, John A [Littleton, CO

    2007-07-24

    A nitridation treated stainless steel article (such as a bipolar plate for a proton exchange membrane fuel cell) having lower interfacial contact electrical resistance and better corrosion resistance than an untreated stainless steel article is disclosed. The treated stainless steel article has a surface layer including nitrogen-modified chromium-base oxide and precipitates of chromium nitride formed during nitridation wherein oxygen is present in the surface layer at a greater concentration than nitrogen. The surface layer may further include precipitates of titanium nitride and/or aluminum oxide. The surface layer in the treated article is chemically heterogeneous surface rather than a uniform or semi-uniform surface layer exclusively rich in chromium, titanium or aluminum. The precipitates of titanium nitride and/or aluminum oxide are formed by the nitriding treatment wherein titanium and/or aluminum in the stainless steel are segregated to the surface layer in forms that exhibit a low contact resistance and good corrosion resistance.

  18. Permeation of chromium salts through human skin in vitro

    DEFF Research Database (Denmark)

    Gammelgaard, Bente; Fullerton, A; Avnstorp, C

    1992-01-01

    of the dichromate solution. Chromium skin levels increased with increasing concentrations of applied chromium salts up to 0.034 M Cr. The amount of chromium in recipient phase and skin layers increased with increasing pH when the applied solution contained potassium dichromate. This was ascribed to a decreased skin...... barrier function of the skin. The amount of chromium found in all skin layers after application of chromium chloride decreased with increasing pH due to lower solubility of the salt. The % of chromium found in the recipient phase as chromium(VI) increased with increasing total chromium concentration...

  19. Novel high chromium containing braze filler metals for heat exchanger applications

    Energy Technology Data Exchange (ETDEWEB)

    Rangaswamy, S.; Fortuna, D. [Sulzer Metco, Troy (United States)

    2007-07-01

    A new family of boron-free, high chromium containing braze filler metal compositions were developed (Amdry 105, Amdry 108, Amdry 805). Filler metal properties including metallurgical phases, melting range, flow, corrosion resistance and high temperature oxidation resistance are reported. Additionally, the technical and economical advantages of using these new filler metals in fabricating flat plate type of heat exchangers and metallic catalytic converters is discussed. (orig.)

  20. TO SELECTION OF TECHNOLOGICAL SCHEME OF SOFTENING HEAT TREATMENT FOR HIGH CHROMIUM CAST IRON

    Directory of Open Access Journals (Sweden)

    V. G. Efremenko

    2014-03-01

    Full Text Available Purpose. High chromium cast irons with austenitic matrix have low machinability. The aim of work is search of new energy-saving modes of preliminary softening heat treatment enhancing the machinability of castings by forming an optimum microstructure. Methodology. Metallographic analysis, hardness testing and machinability testing are applied. Findings. It was found out that high temperature annealing with continuous cooling yields to martensite-austenite matrix in cast iron 270Х15Г2Н1MPhT, which abruptly affects the machinability of cast iron. Significant improvement of machinability is achieved by forming of structure "ferrite + granular carbides" and by decline of hardness to 37-39 HRC in the case of two-stage isothermal annealing in the subcritical temperature range or by the use of quenching and tempering (two-step or cyclic. Originality. It was found that the formation of the optimal structure of the matrix and achievement of desired hardness level needed for improving machinability of high chromium cast iron containing 3 % austenite-forming elements, can be obtained: 1 due to pearlite original austenite followed by spherodization eutectoid carbides, and 2 by getting predominantly martensite structure followed by the decay of martensite and carbides coagulation at high-temperature tempering. Practical value. The new energy-saving schemes of softening heat treatment to ensure the growth of machinability of high chromium cast iron, alloyed by higher quantity of austenite forming elements, are proposed.

  1. Abrasion Resistance of as-Cast High-Chromium Cast Iron

    Directory of Open Access Journals (Sweden)

    Pokusová Marcela

    2014-12-01

    Full Text Available High chromium cast irons are widely used as abrasion resistant materials. Their properties and wear resistance depend on carbides and on the nature of the matrix supporting these carbides. The paper presents test results of irons which contain (in wt.% 18-22 Cr and 2-5 C, and is alloyed by 1.7 Mo + 5 Ni + 2 Mn to improve the toughness. Tests showed as-cast irons with mostly austenitic matrix achieved hardness 36-53 HRC but their relative abrasion-resistance was higher than the tool steel STN 19436 heat treated on hardness 60 HRC.

  2. Material properties of and tissue reaction to the Slocum TPLO plate.

    Science.gov (United States)

    Boudrieau, Randy J; McCarthy, Robert J; Sprecher, Christoph M; Künzler, Tobias P; Keating, John H; Milz, Stefan

    2006-07-01

    To determine the material properties of Slocum TPLO plates and assess the soft tissue reaction adjacent to these plates in dogs that had undergone tibial plateau leveling osteotomy (TPLO). 3 new TPLO plates, 8 retrieved TPLO plates, and 1 new Synthes dynamic compression plate. Metallurgic analyses were performed. Tissue samples were obtained from areas adjacent to retrieved plates and submitted for histologic examination. All of the TPLO plates had a 2-phase microstructure consisting of austenite and ferrite in various amounts. Residua, inclusions, and cavities were seen during microscopic examination of the plate surface. The major differences between new and retrieved TPLO plates were the presence of small gaps separating many inclusions from the surrounding matrix and the presence of various-sized pits on the surface of the retrieved plates. The dynamic compression plate had a nearly pure austenitic structure and was largely free from residua, inclusions, and cavities. Histologic examination of tissue samples obtained from areas adjacent to retrieved TPLO plates revealed intra- and extracellular particulate debris. Two types of particles (one consisting of chromium, nickel, molybdenum, and iron and the other consisting of aluminum and silicon) were seen. Results determined that new and retrieved TPLO plates were manufactured from 316L stainless steel and produced by a casting process, but not all plates met specifications for chemical composition of cast surgical implants (American Society for Testing Materials standard F745); tissues surrounding retrieved plates had evidence of adverse reactions, probably as a result of plate corrosion.

  3. seasonal variation in chromium hexavalent and copper ...

    African Journals Online (AJOL)

    Admin

    that chromium hexavalent and copper enrichment occurred in the rainy season in the order of Cr+6chromium hexavalent and ...

  4. Chromium tolerance and reduction potential of Staphylococci ...

    African Journals Online (AJOL)

    In order to study the microbiology of chromium tolerance and reduction at a fly ash dumping site in South Africa, 15 core samples were investigated. It was shown that the 30 year old dumping site exhibited high concentrations of Cr (VI) ranging from 1.6 to 9.6 mg/g. From this contaminated fly ash dumping site, 67 chromium ...

  5. Synthesis and investigation of CrB{sub 4}, MnB{sub 4} and new ternary chromium and rhenium manganese borides; Synthese und Untersuchung von CrB{sub 4}, MnB{sub 4} sowie neuen ternaeren Chrom- und Rheniummanganboriden

    Energy Technology Data Exchange (ETDEWEB)

    Knappschneider, Arno

    2014-10-13

    In the present work single crystals of the tetraborides of chromium and manganese have been grown and allowed a structure refinement of the compounds. Furthermore the physical characteristics for example hardness, electronic properties and magnetism were been determined. Also the ternary tetraboride phase of chromium and manganese was synthesized and a new ternary rhenium manganese diboride could be obtained.

  6. Structure and properties of GMA surfaced armour plates

    OpenAIRE

    A. Klimpel; K. Luksa; Burda, M.

    2010-01-01

    Purpose: In the combat vehicles many materials can be used for the armour. Application of the monolithic armour plates in light combat vehicles is limited by the high armour weigh. Introduction of the layered armour plates is a way to limit the vehicle weight. In the paper test results of graded and nanostructural GMA surfaced armour plates are presented.Design/methodology/approach: Metallographic structure, chemical composition and hardness of surfaced layers were investigated in order to ex...

  7. Forces Between a Permanent Magnet and a Soft Magnetic Plate

    DEFF Research Database (Denmark)

    Beleggia, Marco; Vokoun, David; De Graef, Marc

    2012-01-01

    Forces between a hard/permanent magnet of arbitrary shape and an ideally soft magnetic plate in close proximity are derived analytically from the image method applied to magnetostatics. We found that the contact force, defined as the force required to detach the hard magnet from the plate......, coincides with that between two identical touching permanent magnets. Furthermore, if the hard and the soft magnets are displaced by some amount, their attraction equals that between two identical permanent magnets displaced by twice that amount. Experimental results are presented that validate...

  8. Magnetochemistry of chromium (III) (abstract)

    Science.gov (United States)

    Merabet, K. E.; Burriel, R.; Carlin, Richard L.

    1988-04-01

    There are relatively few superexchange-coupled antiferromagnets of chromium (III), largely because the exchange interactions are so weak. We have begun a program to study these materials and present magnetic susceptibility measurements on several new systems. We find that a polycrystalline sample of [Cr(NH3)5Cl]Cl2 behaves as a magnetic linear chain, and orders antiferromagnetically at about 600 mK, and that single crystals of [Cr(en)3]X3ṡ3H2O order at 130 mK when X is chloride. The analogous bromide orders at 112 mK. The chloride exhibits an easy axis, parallel to the longitudinal axis, while the bromide exhibits an easy plane. The data have been successfully fitted by several different procedures which result in much the same parameters. In addition to the exchange, it is necessary to include in the analysis the zero-field splitting of the chromium ions. The zero-field splitting in paramagnetic NaMg[Cr(oxalate)3]ṡ9H2O has also been measured.

  9. Create Your Plate

    Medline Plus

    Full Text Available ... Pacific Islanders American Indian/Alaska Native Programs Older Adults Family Link Diabetes EXPO Upcoming Diabetes EXPOs EXPO ... Plate! Click on the plate sections below to add your food choices. Reset Plate Share Create Your ...

  10. Growth Plate Fractures

    Science.gov (United States)

    .org Growth Plate Fractures Page ( 1 ) The bones of children and adults share many of the same risks for ... also subject to a unique injury called a growth plate fracture. Growth plates are areas of cartilage ...

  11. Create Your Plate

    Medline Plus

    Full Text Available ... Plate! Click on the plate sections below to add your food choices. Reset Plate Share Create Your ... your protein. See this list of protein foods . Add a serving of fruit , a serving of dairy ...

  12. Create Your Plate

    Medline Plus

    Full Text Available ... Plate Create Your Plate is a simple and effective way to manage your blood glucose levels and ... Steps to Create Your Plate It's simple and effective for both managing diabetes and losing weight. Creating ...

  13. Create Your Plate

    Medline Plus

    Full Text Available ... that your options are endless. Create Your Plate! Click on the plate sections below to add your ... down the middle of the plate. Then on one side, cut it again so you will have ...

  14. Removal of Hexavalent Chromium from Aqueous Solution by Using Adsorption onto Commerical Iron Powder; Study of Equilibrium and Kinetics

    Directory of Open Access Journals (Sweden)

    A.R. Rahmani

    2011-10-01

    Full Text Available Introduction & Objective: Industrial wastewaters including heavy metals, are one of the important sources of environmental pollution. Heavy metals such as chromium is found in plating wastewater and is harmful for human health and environment. The purpose of the present study was to investigate adsorption of hexavalent chromium Cr (VI from aqueous solution onto commerical Iron powder as an effective, faster ,and cheaper adsorbent. Materials & Methods: This research was an experimental- lablatory study done in batch system. This study investigated the removal of hexavalent chromium by using commerical Iron powder with variation pH, contact time, Iron powder dose and initial hexavalent chromium concentration in batch system , and the result was analyzed by Excel software.Results: The results showed that the removal efficiency decreased with increasing pH and initial chromium concentration. Also the results showed that the removal efficiency increased with increasing Iron powder dose and contact time. With increasing adsorbent dose from 0.1g/100cc to 1.5 g/100cc, the removal efficiency increased from 47.5% to 92.5 % in constant conditions (pH=7, initial hexavalent chromium concentration = 20 mg/L . Also removal efficiency increased from 41.1% to 48.5% with increasing contact time from 2 min to 120 min in constant conditions (pH=7, Iron powder= 0.1g/100cc, initial hexavalent chromium concentration= 20 mg/L. Experimental isotherms and kinetics models were assessed by Langmuir and Freundlich isotherms and pseudo-first-order, pseudo-second-order kinetics and modifed pseudo-first-order models. The results showed that the data were acceptably explained by Langmuir isotherms and pseudo-second-order kinetics models, respectively. Conclusion: The results showed that the removal of hexavalent chromium from aqueous solution using sawdust can be done faster and cheaper. (Sci J Hamadan Univ Med Sci 2011;18(3:33-39

  15. Experimental patch testing with chromium-coated materials

    DEFF Research Database (Denmark)

    Bregnbak, David; Thyssen, Jacob P; Jellesen, Morten Stendahl

    2017-01-01

    Chromium coatings on metal alloys can be decorative, and prevent corrosion and metal ion release. We recently showed that handling of a chromium-containing disc resulted in chromium deposition on the skin. To examine patch test reactivity to chromium-coated discs. We included 15 patients: 10 chro...

  16. Structural effects of metallic chromium on its electrochemical behavior

    Directory of Open Access Journals (Sweden)

    VELIMIR RADMILOVIC

    2007-06-01

    Full Text Available Chromium dissolution in aqueous sulfuric acid solution of pH 1 was studied electrochemically on chromium electrodes with different crystallographic structures. A slow potentiodynamic method was used for the electrochemical measurements in deaerated solutions (purgedwith nitrogen,while the Cr(III ions in the solution after the corrosion were determined by atomic absorption spectrometry. Three electrode materials with a very dominant crystallite orientation resembling single crystal structures (i.e., 111 and 110 confirmed by the electron backscattering diffraction (EBSD, were used in the experiments. The (111 structures were somewhat more active electrochemically (both anodic and cathodic than the (110 structure. However, Cr electrochemically deposited in standard plating bath, assumed from literature data to has also the (111 structure, was more than 4 times active for anodic dissolution and, by the same number, less active for cathodic hydrogen evolution. The concentrations of Cr(III ions determined in the solution after definite times of corrosion of all the materials showed almost two times larger dissolution rates than observed electrochemically by three different electrochemical methods (Wagner–Traud, Stern–Geary, electrochemical impedance spectroscopy. This is explained by the simultaneous occurrence of potential independent chemical dissolution of Cr, by a direct reaction of metallic Cr with H2O molecules, proposed a long time ago by Kolotyrkin and coworkers.

  17. Hardness Tester for Polyur

    Science.gov (United States)

    Hauser, D. L.; Buras, D. F.; Corbin, J. M.

    1987-01-01

    Rubber-hardness tester modified for use on rigid polyurethane foam. Provides objective basis for evaluation of improvements in foam manufacturing and inspection. Typical acceptance criterion requires minimum hardness reading of 80 on modified tester. With adequate correlation tests, modified tester used to measure indirectly tensile and compressive strengths of foam.

  18. Low-chromium reduced-activation chromium-tungsten steels

    Energy Technology Data Exchange (ETDEWEB)

    Klueh, R.L.; Alexander, D.J.; Maziasz, P.J. [Oak Ridge National Lab., TN (United States)

    1996-10-01

    Bainitic microstructures formed during continuous cooling can differ from classical upper and lower bainite formed during isothermal transformation. Two types of non-classical bainite were observed depending on the cooling rate: carbide-free acicular bainite at rapid cooling rates and granular bainite at slower cooling rates. The Charpy impact toughness of the acicular ferrite was found to be considerably better than for the granular bainite. It was postulated that alloying to improve the hardenability of the steel would promote the formation of acicular bainite, just as increasing the cooling rate does. To test this, chromium and tungsten were added to the 2 1/4Cr-2W and 2 1/4Cr-2WV steel compositions to increase their hardenability, and the microstructures and mechanical properties were examined.

  19. Reproductive toxicological aspects of chromium in males

    Energy Technology Data Exchange (ETDEWEB)

    Ernst, E.

    1994-12-31

    To expand our present understanding of the effects of chromium on male fertility a number of studies were designed to achieve this through the use of chromium intoxicated experimental animals and through investigation of sexual hormones and sperm quality in welders. Also in view of the lack of an experimental model for effects of noxious substance on the epididymal spermatozoa the main objectives of the series of studies reviewed here were: A. To establish a model for evaluation of epididymal sperm count and motility in the rat. B. To investigate and compare the effects of tri- and hexavalent chromium on epididymal spermatozoa. Further to describe the effects of low-dose long-time exposure of rats to the most toxicological interesting chromium oxidative state - hexavalent chromium. C. By the use of autoradiography and {gamma}-countinuing to expand the present knowledge on the distribution of chromium in the body with special reference to the male reproductive organs. D. To describe the effects of exposure to hexavalent chromium in welding fume on levels of sexual hormones and semen parameters in welders. (EG).

  20. Performance Evaluation of 316L-Q345R Stainless Steel Clad Plate

    OpenAIRE

    JIN He-rong; YANG Xu-kun; YI Ya-li

    2016-01-01

    Performance of 316L-Q345R stainless steel clad plate prepared by vacuum hot-rolling was evaluated from two aspects of the microstructure and micro-hardness. Microstructure topography and constituent of clad plate were investigated by scanning electron microscope and energy spectrum analysis, and changing rules of phase structure and constituent were also studied. Relationship between microstructure and hardness was studied by testing the hardness of interface between stainless steel and carbo...

  1. Chromium(VI) is more toxic than chromium(III) to freshwater algae: a paradigm to revise?

    Science.gov (United States)

    Vignati, Davide A L; Dominik, Janusz; Beye, Mamadou L; Pettine, Maurizio; Ferrari, Benoît J D

    2010-07-01

    The behavior and toxicity of Cr(III) and Cr(VI) to the green algae Pseudokirchneriella subcapitata and Chlorella kessleri were studied in a standard culture medium (ISO medium) and, for P. subcapitata only, in ultrafiltered natural water enriched with all ISO components (modified ISO medium). In all solutions amended with Cr(III), initial chromium concentrations decreased by 60-90% over 72h (the duration of algal tests) indicating that protocols for testing poorly soluble substances are required to properly evaluate Cr(III) toxicity. After accounting for its behavior in test solutions, chromium(III) was 5-10 times more toxic than Cr(VI) in both media. For P. subcapitata, the average 72h EC50 of Cr(III) in ISO medium was 17.4+/-4.7 microg/L (n=9); lower than corresponding hardness-corrected Continuous Concentration Criteria of the US EPA and well within the range of Cr concentrations found in waters impacted by tannery discharges. These results follow from intrinsic chemical properties of Cr(III) in circumneutral solutions, so that the actual toxicity of Cr(III) to aquatic organisms may be generally underestimated. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  2. Subgroup report on hard x-ray microprobes

    Energy Technology Data Exchange (ETDEWEB)

    Ice, G.E. [Oak Ridge National Lab., TN (United States); Barbee, T.; Bionta, R. [Lawrence Livermore National Lab., CA (United States); Howells, M.; Thompson, A.C. [Lawrence Berkeley Lab., CA (United States); Yun, W. [Argonne National Lab., IL (United States)

    1994-09-01

    The increasing availability of synchrotron x-ray sources has stimulated the development of advanced hard x-ray (E{>=}5 keV) microprobes. New x-ray optics have been demonstrated which show promise for achieving intense submicron hard x-ray probes. These probes will be used for extraordinary elemental detection by x-ray fluorescence/absorption and for microdiffraction to identify phase and strain. The inherent elemental and crystallographic sensitivity of an x-ray microprobe and its inherently nondestructive and penetrating nature makes the development of an advanced hard x-ray microprobe an important national goal. In this workshop state-of-the-art hard x-ray microprobe optics were described and future directions were discussed. Gene Ice, Oak Ridge National Laboratory (ORNL), presented an overview of the current status of hard x-ray microprobe optics and described the use of crystal spectrometers to improve minimum detectable limits in fluorescent microprobe experiments. Al Thompson, Lawrence Berkeley Laboratory (LBL), described work at the Center for X-ray Optics to develop a hard x-ray microprobe based on Kirkpatrick-Baez (KB) optics. Al Thompson also showed the results of some experimental measurements with their KB optics. Malcolm Howells presented a method for bending elliptical mirrors and Troy Barbee commented on the use of graded d spacings to achieve highest efficiency in KB multilayer microfocusing. Richard Bionta, Lawrence Livermore National Laboratory (LLNL), described the development of the first hard x-ray zone plates and future promise of so called {open_quotes}jelly roll{close_quotes} or sputter slice zone plates. Wenbing Yun, Argonne National Laboratory (ANL), described characterization of jelly roll and lithographically produced zone plates and described the application of zone plates to focus extremely narrow bandwidths by nuclear resonance. This report summarizes the presentations of the workshop subgroup on hard x-ray microprobes.

  3. Comprehensive hard materials

    CERN Document Server

    2014-01-01

    Comprehensive Hard Materials deals with the production, uses and properties of the carbides, nitrides and borides of these metals and those of titanium, as well as tools of ceramics, the superhard boron nitrides and diamond and related compounds. Articles include the technologies of powder production (including their precursor materials), milling, granulation, cold and hot compaction, sintering, hot isostatic pressing, hot-pressing, injection moulding, as well as on the coating technologies for refractory metals, hard metals and hard materials. The characterization, testing, quality assurance and applications are also covered. Comprehensive Hard Materials provides meaningful insights on materials at the leading edge of technology. It aids continued research and development of these materials and as such it is a critical information resource to academics and industry professionals facing the technological challenges of the future. Hard materials operate at the leading edge of technology, and continued res...

  4. Chromium in leather footwear-risk assessment of chromium allergy and dermatitis

    DEFF Research Database (Denmark)

    Thyssen, Jacob P; Strandesen, Maria; Poulsen, Pia B

    2012-01-01

    Background. Chromium-tanned leather footwear, which releases >3 ppm hexavalent Cr(VI), may pose a risk of sensitizing and eliciting allergic dermatitis. Objectives. To determine the content and potential release of chromium in leather footwear and to discuss the prevention of chromium contact...... allergy and dermatitis. Methods. Sixty pairs of leather shoes, sandals and boots (20 children's, 20 men's, and 20 women's) were purchased in Copenhagen and examined with X-ray fluorescence spectroscopy. Chromium was extracted according to the International Standard, ISO 17075. The detection level for Cr......(VI) was 3 ppm. Results. Chromium was identified in 95% of leather footwear products, the median content being 1.7% (range 0-3.3%). No association with store category or footwear category was found. A tendency for there to be a higher chromium content in footwear with high prices was shown (p(trend) = 0...

  5. Characteristics of chromium-allergic dermatitis patients prior to regulatory intervention for chromium in leather

    DEFF Research Database (Denmark)

    Bregnbak, David; Thyssen, Jacob P; Zachariae, Claus

    2014-01-01

    BACKGROUND: Chromium-tanned leather articles currently constitute the most important cause of contact allergy to chromium in Denmark. A regulation on the content of hexavalent chromium in leather was adopted in November 2013 by the EU member states. OBJECTIVES: To characterize patients...... with chromium allergy and their disease, to serve as a baseline for future studies on the potential effect of the new regulation on chromium in leather. METHODS: A questionnaire case-control study was performed on 155 dermatitis patients with positive patch test reactions to potassium dichromate and a matched...... control group of 621 dermatitis patients. Comparisons were made by use of a χ(2) -test and the Mann-Whitney U-test. Logistic regression analyses were used to test for associations. RESULTS: Sixty-six per cent of chromium-allergic patients had a positive history of contact dermatitis caused by leather...

  6. Leaching of chromium from chromium contaminated soil: Speciation study and geochemical modeling

    Directory of Open Access Journals (Sweden)

    Anđelković Darko H.

    2012-01-01

    Full Text Available Distribution of chromium between soil and leachate was monitored. A natural process of percolating rainwater through the soil was simulated in the laboratory conditions and studied with column leaching extraction. Migration of chromium in the soil is conditioned by the level of chromium soil contamination, the soil organic matter content, and rainwater acidity. Chromium (III and chromium(VI were determined by spectrophotometric method with diphenilcarbazide in acidic media. Comparing the results of chromium speciation in leachate obtained by experimental model systems and geochemical modelling calculations using Visual MINTEQ model, a correlation was observed regarding the influence of the tested parameters. Leachate solutions showed that the concentration of Cr depended on the organic matter content. The influence of pH and soil organic matter content is in compliance after its definition through experimental and theoretical way. The computer model - Stockholm Humic Model used to evaluate the leaching results corresponded rather well with the measured values.

  7. Effects of tungsten on erosion-corrosion behavior of high chromium white cast iron

    Energy Technology Data Exchange (ETDEWEB)

    Mousavi Anijdan, S.H. [Mining, Metals and Materials Engineering Department, McGill University, M.H. Wong Building, 3610 University Street, Montreal, H3A 2B2 (Canada); Materials Science and Engineering Department, Sharif University of Technology, P.O. Box 11365-9944, Tehran (Iran, Islamic Republic of)], E-mail: hashem.mousavi@mail.mcgill.ca; Bahrami, A. [Department of Materials Science and Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft (Netherlands); Varahram, N. [Materials Science and Engineering Department, Sharif University of Technology, P.O. Box 11365-9944, Tehran (Iran, Islamic Republic of); Davami, P. [Materials Science and Engineering Department, Sharif University of Technology, P.O. Box 11365-9944, Tehran (Iran, Islamic Republic of)

    2007-04-25

    In this study, effects of tungsten on wear resistance of high chromium white cast iron with and without tungsten in erosion-corrosion condition have been investigated. At the same time, the comparison between wear resistance of this grade of cast iron and low alloy steels with various contents of Cr which are used in industrial condition (in Sarcheshme Company, the greatest copper production company in the Middle East and with more than 4000 years historical cupper production background) was studied, while, copper concentrates have used for erosion particles. Results show that, because of higher hardness of matrix due to the tungsten, the wear resistance of high chromium cast iron increases. In addition to that, combine cutting and deformation wear mechanism and spalling mechanism were attributed in high chromium cast iron and low alloy steels, respectively. Subsequently, pitting mechanism in corrosion aspect was recognized because of inhomogeneity in chemical composition and sulfide inclusions content. Finally, the combine effects of erosion and corrosion (synergetic effect) were recognized in the high chromium white iron in industrial condition for the damaged samples.

  8. The Effect of Addition of Titanium on The Structure and Properties of High Chromium Cast Iron

    Directory of Open Access Journals (Sweden)

    Kopyciński D.

    2015-09-01

    Full Text Available The paper presents results of Ti-addition to High Chromium Cast Iron (HCCI on the structure and selected mechanical properties. For this study casted two sets of cylinders with dimensions ø20 mm, ø15 mm × 250 mm, for the High Chromium Cast Iron (HCCI and with the 4% by mass Ti-addition. Melts were performed in the induction furnace crucible capacity of 15 kg. During the heats the cup with installed S type thermocouple was poured to record the cooling curves. The cylinders were subjected to the static bending strength test. Samples for the test microstructure and Rockwell hardness were cut from the cylinders. The study shows that the addition of titanium had an impact on the structure and thus the properties of High Chromium Cast Iron (HCCI. In subsequent studies, through an appropriate choice of chemical composition and proper process control, it is planned to obtain in the structure the titanium carbides TiC and chromium carbides with type (Cr, Fe7C3.

  9. Chrome-Free Paint Primer for Zn/Ni Plated High-Strength Steel (Briefing Charts)

    Science.gov (United States)

    2014-11-19

    Chrome -Free Paint Primer for Zn/Ni Plated High- Strength Steel 11-19-14 Presentation at ASETSDefense 2014 George Zafiris Team: Mark Jaworowski, Mike...AND SUBTITLE Chrome -Free Paint Primer for Zn/Ni Plated High-Strength Steel 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6... Chrome -free Primer TCP LHE= Low Hydrogen Embrittlement CCC= Chromate (Cr6+) Conversion Coating TCP= Trivalent (Cr3+) Chromium Process  Regulatory EHS

  10. Chromium isotope uptake in carbonates

    DEFF Research Database (Denmark)

    Rodler, Alexandra

    retain an isotopically light Cr signature. Cr(VI) enriched in heavy Cr isotopes is then transported via river waters to the oceans and sequestered into marine sediments. Marine chemical sediments such asbanded iron formations and modern marine carbonates have proven useful in recording the Cr isotope...... with calcium carbonate in order to test the reliability of the Cr carbonate compositions. Several experimental approaches have been employed to elucidate the fractionation behavior of Cr isotopes when Cr(VI) is incorporated into calcium carbonate phases. These results indicate that at lower Cr concentrations......Chromium (Cr) is a redox sensitive element potentially capable of tracing fine-scale fluctuations of the oxygenation of Earth’s early surface environments and seawater. The Cr isotope composition of carbonates could perhaps be used as paleo-redox proxy to elucidate changes in the geological past...

  11. Mechanical properties of metal-ceramic systems from nickel-chromium and cobalt-chromium alloys

    Directory of Open Access Journals (Sweden)

    Mirković Nemanja

    2007-01-01

    Full Text Available Background/Aim. Metal-ceramic bond strength and alloys' elastic modulus clearly determine the potential of alloy application, because the ceramic integrity during mastication depends on these two characteristics. The aim of this study was to evaluate metal-ceramic bond strength and elastic modulus of cobalt-chromium alloys in making porcelainfused- to-metal restorations, regarding the application of the most frequent nickel-chromium alloy. Methods. The research was performed as an experimental study. Six metalceramic samples were made from nickel-chromium alloy (Wiron 99 and cobalt-chromium alloy (Wirobond C, according to the manufactures manuals and instructions from ISO 9693: 1996. Three-point bending test was performed up to the ceramic fracture. The fracture load was measured on an universal testing machine (Zwick, type 1464, with cross-head speed of 0,05mm/min. Results. The results of this study confirmed the significant differences between the metal-ceramic bond strength (p < 0.01 and elastic modulus (p < 0.001 of nickel-chromium and cobalt-chromium alloys, where cobalt-chromium alloys showed higher values for both tested parameters. Conclusion. Cobalt-chromium metal-ceramic alloys can successfully replace nickel-chromium alloys, especially for fabrication of long-span metal-ceramic bridges due to the great flexural strength.

  12. [Mechanical properties of metal-ceramic systems from nickel-chromium and cobalt-chromium alloys].

    Science.gov (United States)

    Mirković, Nemanja

    2007-04-01

    Metal-ceramic bond strength and alloys' elastic modulus clearly determine the potential of alloy application, because the ceramic integrity during mastication depends on these two characteristics. The aim of this study was to evaluate metal-ceramic bond strenght and elastic modulus of cobalt-chromium alloys in making porcelain-fused-to-metal restorations, regarding the application of the most frequent nickel-chromium alloy. The research was performed as an experimental study. Six metal-ceramic samples were made from nickel-chromium alloy (Wiron 99) and cobalt-chromium alloy (Wirobond C), according to the manufactures manuals and instructions from ISO 9693: 1996. Three-point bending test was performed up to the ceramic fracture. The fracture load was measured on an universal testing machine (Zwick, type 1464), with cross-head speed of 0,05mm/min. The results of this study confirmed the significant differences between the metal-ceramic bond strength (p chromium and cobalt-chromium alloys, where cobalt-chromium alloys showed higher values for both tested parameters. Cobalt-chromium metal-ceramic alloys can successfully replace nickel-chromium alloys, especially for fabrication of long-span metal-ceramic bridges due to the great flexural strength.

  13. 78 FR 9676 - Clad Steel Plate From Japan: Continuation of Antidumping Duty Order

    Science.gov (United States)

    2013-02-11

    ... them from products metalized in other manners (e.g., by normal electroplating). The various cladding... welding (e.g., electrocladding), in which the cladding metal (nickel, chromium, etc.) is applied to the...). Stainless clad steel plate is manufactured to American Society for Testing and Materials (ASTM...

  14. Current plate motions

    Science.gov (United States)

    Demets, C.; Gordon, R. G.; Argus, D. F.; Stein, S.

    1990-05-01

    A global plate motion model, named NUVEL-1, which describes current plate motions between 12 rigid plates is described, with special attention given to the method, data, and assumptions used. Tectonic implications of the patterns that emerged from the results are discussed. It is shown that wide plate boundary zones can form not only within the continental lithosphere but also within the oceanic lithosphere; e.g., between the Indian and Australian plates and between the North American and South American plates. Results of the model also suggest small but significant diffuse deformation of the oceanic lithosphere, which may be confined to small awkwardly shaped salients of major plates.

  15. Localized Corrosion of Chromium Coated Steel

    NARCIS (Netherlands)

    Zhang, X.; Beentjes, P.; Mol, A.; Terryn, H.

    2006-01-01

    In this paper, we report on the studies of the local corrosion behaviour of chromium-coated ultra low carbon steel in NaCl solution using polarization, electrochemical impedance spectroscopy (EIS) and SVET.

  16. Potentiometry: A Chromium (III) -- EDTA Complex

    Science.gov (United States)

    Hoppe, J. I.; Howell, P. J.

    1975-01-01

    Describes an experiment that involves the preparation of a chromium (III)-EDTA compound, a study of its infrared spectrum, and the potentiometric determination of two successive acid dissociation constants. (Author/GS)

  17. Hard probes 2006 Asilomar

    CERN Multimedia

    2006-01-01

    "The second international conference on hard and electromagnetic probes of high-energy nuclear collisions was held June 9 to 16, 2006 at the Asilomar Conference grounds in Pacific Grove, California" (photo and 1/2 page)

  18. Crystal Indentation Hardness

    Directory of Open Access Journals (Sweden)

    Ronald W. Armstrong

    2017-01-01

    Full Text Available There is expanded interest in the long-standing subject of the hardness properties of materials. A major part of such interest is due to the advent of nanoindentation hardness testing systems which have made available orders of magnitude increases in load and displacement measuring capabilities achieved in a continuously recorded test procedure. The new results have been smoothly merged with other advances in conventional hardness testing and with parallel developments in improved model descriptions of both elastic contact mechanics and dislocation mechanisms operative in the understanding of crystal plasticity and fracturing behaviors. No crystal is either too soft or too hard to prevent the determination of its elastic, plastic and cracking properties under a suitable probing indenter. A sampling of the wealth of measurements and reported analyses associated with the topic on a wide variety of materials are presented in the current Special Issue.

  19. Chromium in human nutrition: a review.

    Science.gov (United States)

    Mertz, W

    1993-04-01

    This review summarizes the results of 15 controlled studies supplementing defined Cr(III) compounds to subjects with impaired glucose tolerance. Three of these (3-4 mumol Cr/d for > 2 mo) produced no beneficial effects: serum glucose, insulin and lipid concentrations remained unchanged. The remaining 12 interventions improved the efficiency of insulin or the blood lipid profile of subjects (ranging from malnourished children and healthy middle-aged individuals to insulin-requiring diabetics). In addition, three cases of impaired glucose tolerance after long-term total parenteral alimentation responding to Cr supplementation have been reported. Chromium potentiates the action of insulin in vitro and in vivo; maximal in vitro activity requires a special chemical form, termed Glucose Tolerance Factor and tentatively identified as a Cr-nicotinic acid complex. Its complete structural identification is a major challenge to chromium research. The development and validation of a procedure to diagnose chromium status is the second challenge. Such a test would allow the assessment of incidence and severity of deficiency in the population and the selection of deficiency in the population and the selection of chromium-responsive individuals. The third challenge is the definition of chromium's mode of action on parameters of lipid metabolism that have been reported from some studies but not others. Future research along these lines might establish whether chromium deficiency is a factor in the much discussed "Syndrome X" of insulin resistance.

  20. REMOVAL OF HEXAVALENT CHROMIUM FROM DRINKING WATER

    Directory of Open Access Journals (Sweden)

    A. R. Asgari ، F. Vaezi ، S. Nasseri ، O. Dördelmann ، A. H. Mahvi ، E. Dehghani Fard

    2008-10-01

    Full Text Available Removal of chromium can be accomplished by various methods but none of them is cost-effective in meeting drinking water standards. For this study, granular ferric hydroxide was used as adsorbent for removal of hexavalent chromium. Besides, the effects of changing contact time, pH and concentrations of competitive anions were determined for different amounts of granular ferric hydroxide. It was found that granular ferric hydroxide has a high capacity for adsorption of hexavalent chromium from water at pH≤7 and in 90 min contact time. Maximum adsorption capacity was determined to be 0.788 mg Cr+6/g granular ferric hydroxide. Although relatively good adsorption of sulfate and chloride had been specified in this study, the interfering effects of these two anions had not been detected in concentrations of 200 and 400 mg/L. The absorbability of hexavalent chromium by granular ferric hydroxide could be expressed by Freundlich isotherm with R2>0.968. However, the disadvantage was that the iron concentration in water was increased by the granular ferric hydroxide. Nevertheless, granular ferric hydroxide is a promising adsorbent for chromium removal, even in the presence of other interfering compounds, because granular ferric hydroxide treatment can easily be accomplished and removal of excess iron is a simple practice for conventional water treatment plants. Thus, this method could be regarded as a safe and convenient solution to the problem of chromium-polluted water resources.

  1. Pulse Reversal Plating of Nickel and Nickel Alloys for MEMS

    DEFF Research Database (Denmark)

    Tang, Peter Torben

    2001-01-01

    Pulse plating has previously been reported to improve the properties of nickel and nickel alloy deposits. Typically, focus has been on properties such as grain size, hardness and smoothness. When pulse plating is to be utilized for micro electromechanical systems (MEMS), internal stress...... and material distribution is even more important. Using a bath consisting mostly of nickel chloride, pulse reversal plating of both pure nickel and nickel-cobalt alloys has been used to fabricate tools for micro-injection molding. Pulse reversal plating of ternary soft-magnetic alloys, comprising 45-65 percent...

  2. Hardness amplification in nondeterministic logspace

    OpenAIRE

    Gupta, Sushmita

    2007-01-01

    A hard problem is one which cannot be easily computed by efficient algorithms. Hardness amplification is a procedure which takes as input a problem of mild hardness and returns a problem of higher hardness. This is closely related to the task of decoding certain error-correcting codes. We show amplification from mild average case hardness to higher average case hardness for nondeterministic logspace and worst-to-average amplification for nondeterministic linspace. Finally we explore possible ...

  3. Chemical and microbial remediation of hexavalent chromium from contaminated soil and mining/metallurgical solid waste: a review.

    Science.gov (United States)

    Dhal, B; Thatoi, H N; Das, N N; Pandey, B D

    2013-04-15

    Chromium is a highly toxic non-essential metal for microorganisms and plants, and its occurrence is rare in nature. Lower to higher chromium containing effluents and solid wastes released by activities such as mining, metal plating, wood preservation, ink manufacture, dyes, pigments, glass and ceramics, tanning and textile industries, and corrosion inhibitors in cooling water, induce pollution and may cause major health hazards. Besides, natural processes (weathering and biochemical) also contribute to the mobility of chromium which enters in to the soil affecting the plant growth and metabolic functions of the living species. Generally, chemical processes are used for Cr- remediation. However, with the inference derived from the diverse Cr-resistance mechanism displayed by microorganisms and the plants including biosorption, diminished accumulation, precipitation, reduction of Cr(VI) to Cr(III), and chromate efflux, bioremediation is emerging as a potential tool to address the problem of Cr(VI) pollution. This review focuses on the chemistry of chromium, its use, and toxicity and mobility in soil, while assessing its concentration in effluents/wastes which becomes the source of pollution. In order to conserve the environment and resources, the chemical/biological remediation processes for Cr(VI) and their efficiency have been summarised in some detail. The interaction of chromium with various microbial/bacterial strains isolated and their reduction capacity towards Cr(VI) are also discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. The effect of carbon content on mechanical properties, failure and corrosion resistance of deposited chromium metal

    Directory of Open Access Journals (Sweden)

    Леонід Кімович Лещинськiй

    2017-06-01

    Full Text Available It has been shown that if choosing a metal composition for surfacing rolls and rollers of continuous casting machines, both the carbon impact on the mechanical and functional properties and the critical values of the chromium concentration, which determine the corrosion resistance of the metal with regard to electrochemical corrosion theory, should be considered as well. The paper studied the effect of chromium and carbon steel the X5-X12 type on the structure, technological strength, mechanical properties, fracturing resistance and corrosion resistance of the weld metal. The composition of chromium tool steels (deposited metal (X5-used for the rolls of hot rolling mills and (X12-used for continuous casting machines rollers correspond to these values. The impact of carbon on the properties of the deposited metal containing chromium was considered by comparing the data for both types of the deposited metal. It was found that for both types of the deposited metal (X5 and X12, the limiting value of the carbon content, providing an optimal combination of strength, ductility, failure resistance is the same. If the carbon content is more than the limiting value – (0,25% the technological strength and failure resistance of the deposited metal significantly reduce. With increasing carbon content from 0,18 to 0,25% the martensite structure has a mixed morphology – lath and plate. The strength and toughness of the deposited metal grow. Of particular interest is simultaneous increase in the specific work of failure resulted from crack inhibition at the boundary with far less solid and more ductile ferrite. As for the 5% chromium metal, the X12 type composition with 0,25% C, is borderline. With a further increase in the carbon content of the metal both ductility and failure resistance sharply decrease and with 0,40% C the growth rate of fatigue crack increases by almost 1,5 times

  5. Developing very hard nanostructured bainitic steel

    Energy Technology Data Exchange (ETDEWEB)

    Amel-Farzad, H., E-mail: hh_amel@yahoo.com [Department of Materials Engineering and Metallurgy, Faculty of Engineering, Bu-Ali Sina University, Hamedan (Iran, Islamic Republic of); Department of Materials Engineering, Faculty of Engineering, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Faridi, H.R., E-mail: faridihr@yahoo.com [Department of Materials Engineering and Metallurgy, Hamedan University of Technology, Hamedan (Iran, Islamic Republic of); Rajabpour, F.; Abolhasani, A.; Kazemi, Sh.; Khaledzadeh, Y. [Department of Materials Engineering and Metallurgy, Faculty of Engineering, Bu-Ali Sina University, Hamedan (Iran, Islamic Republic of)

    2013-01-01

    Novel nanostructured high carbon high silicon, carbide-free bainitic steels with very high strength and good ductility have been developed in the recent decade. In this work, an alloy with a high carbon content and no manganese was designed and cast. The prepared samples were heat treated through an austempering process in the range 200-350 Degree-Sign C. Optical and scanning electron microscopes and XRD were used to analyze the microstructures precisely. Bainitic ferrite plates of just a few tens of nanometer thickness were obtained with the hardness of 697{+-}6 HV. It is reasonable to say that the unprecedented hardness values obtained in this work are mostly caused by the extraordinary carbon content of the alloy.

  6. Oral Chromium Exposure and Toxicity

    Science.gov (United States)

    Sun, Hong; Brocato, Jason

    2015-01-01

    Hexavalent chromium [Cr(VI)] is a known carcinogen when inhaled. However, inhalational exposure to Cr(VI) affects only a small portion of the population, mainly by occupational exposures. In contrast, oral exposure to Cr(VI) is widespread and affects many people throughout the globe. In 2008, the National Toxicology Program (NTP) released a 2-year study demonstrating that ingested Cr(VI) was carcinogenic in rats and mice. The effects of Cr(VI) oral exposure is mitigated by reduction in the gut, however a portion evades the reductive detoxification and reaches target tissues. Once Cr(VI) enters the cell, it ultimately gets reduced to Cr(III), which mediates its toxicity via induction of oxidative stress during the reduction while Cr intermediates react with protein and DNA. Cr(III) can form adducts with DNA that may lead to mutations. This review will discuss the potential adverse effects of oral exposure to Cr(VI) by presenting up-to-date human and animal studies, examining the underlying mechanisms that mediate Cr(VI) toxicity, as well as highlighting opportunities for future research. PMID:26231506

  7. Chromium-induced skin damage among Taiwanese cement workers.

    Science.gov (United States)

    Chou, Tzu-Chieh; Wang, Po-Chih; Wu, Jyun-De; Sheu, Shiann-Cherng

    2016-10-01

    Little research has been done on the relationships between chromium exposure, skin barrier function, and other hygienic habits in cement workers. Our purpose was to investigate chromium-induced skin barrier disruption due to cement exposure among cement workers. One hundred and eight cement workers were recruited in this study. Urinary chromium concentration was used to characterize exposure levels. The biological exposure index was used to separate high and low chromium exposure. Transepidermal water loss (TEWL) was used to assess the skin barrier function. TEWL was significantly increased in workers with high chromium exposure levels than those with low chromium exposure levels (p = 0.048). A positive correlation was also found between urinary chromium concentration and TEWL (R = 0.28, p = 0.004). After adjusting for smoking status and glove use, a significant correlation between urinary chromium concentrations and TEWL remained. Moreover, workers who smoked and had a high chromium exposure had significantly increased TEWL compared to nonsmokers with low chromium exposure (p = 0.01). Skin barrier function of cement workers may have been disrupted by chromium in cement, and smoking might significantly enhance such skin barrier perturbation with chromium exposure. Decreased chromium skin exposure and smoking cessation should be encouraged at work. © The Author(s) 2015.

  8. Hard superconducting nitrides

    Science.gov (United States)

    Chen, Xiao-Jia; Struzhkin, Viktor V.; Wu, Zhigang; Somayazulu, Maddury; Qian, Jiang; Kung, Simon; Christensen, Axel Nørlund; Zhao, Yusheng; Cohen, Ronald E.; Mao, Ho-kwang; Hemley, Russell J.

    2005-01-01

    Detailed study of the equation of state, elasticity, and hardness of selected superconducting transition-metal nitrides reveals interesting correlations among their physical properties. Both the bulk modulus and Vickers hardness are found to decrease with increasing zero-pressure volume in NbN, HfN, and ZrN. The computed elastic constants from first principles satisfy c11 > c12 > c44 for NbN, but c11 > c44 > c12 for HfN and ZrN, which are in good agreement with the neutron scattering data. The cubic δ-NbN superconducting phase possesses a bulk modulus of 348 GPa, comparable to that of cubic boron nitride, and a Vickers hardness of 20 GPa, which is close to sapphire. Theoretical calculations for NbN show that all elastic moduli increase monotonically with increasing pressure. These results suggest technological applications of such materials in extreme environments. PMID:15728352

  9. Growth Plate Injuries

    Science.gov (United States)

    ... plate injuries includes: Falling down. Competitive sports (like football). Recreational activities. Sometimes growth plate injuries happen when ... knee. For More Info U.S. Food and Drug Administration Toll free: 888-INFO-FDA (888-463-6332) ...

  10. Create Your Plate

    Science.gov (United States)

    ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal ... Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook ...

  11. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal ... Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook ...

  12. Create Your Plate

    Medline Plus

    Full Text Available ... of Diabetes Research & Practice Home We Are Research Leaders World's Largest Diabetes Meeting Recent Advances Type 1 ... Your Plate It's simple and effective for both managing diabetes and losing weight. Creating your plate lets ...

  13. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate It's simple and effective for both managing diabetes and losing weight. Creating your plate lets you still choose the foods you want, but changes the portion sizes so you are getting larger ...

  14. Create Your Plate

    Medline Plus

    Full Text Available ... this interactive tool. The healthy meal combinations are endless! Ready to try it at home? Just follow ... non-starchy vegetables and that your options are endless. Create Your Plate! Click on the plate sections ...

  15. Create Your Plate

    Medline Plus

    Full Text Available ... Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook ... Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart- ...

  16. Create Your Plate

    Medline Plus

    Full Text Available ... treatments for those living with diabetes. Other Ways to Give Become a Member Vehicle Donation Planned Giving ... Share Create Your Plate ! Share: Seven Simple Steps to Create Your Plate It's simple and effective for ...

  17. Effect of molybdenum, vanadium, boron on mechanical properties of high chromium white cast iron in as-cast condition

    Science.gov (United States)

    Nurjaman, F.; Sumardi, S.; Shofi, A.; Aryati, M.; Suharno, B.

    2016-02-01

    In this experiment, the effect of the addition carbide forming elements on high chromium white cast iron, such as molybdenum, vanadium and boron on its mechanical properties and microstructure was investigated. The high chromium white cast iron was produced by casting process and formed in 50 mm size of grinding balls with several compositions. Characterization of these grinding balls was conducted by using some testing methods, such as: chemical and microstructure analysis, hardness, and impact test. From the results, the addition of molybdenum, vanadium, and boron on high chromium white cast iron provided a significant improvement on its hardness, but reduced its toughness. Molybdenum induced fully austenitic matrix and Mo2C formation among eutectic M7C3 carbide. Vanadium was dissolved in the matrix and carbide. While boron was played a role to form fine eutectic carbide. Grinding balls with 1.89 C-13.1 Cr-1.32 Mo-1.36 V-0.00051 B in as-cast condition had the highest hardness, which was caused by finer structure of eutectic carbide, needle like structure (upper bainite) matrix, and martensite on its carbide boundary.

  18. Serum chromium levels in gestational diabetes mellitus

    Directory of Open Access Journals (Sweden)

    P G Sundararaman

    2012-01-01

    Full Text Available Objective: To measure serum chromium level in women with gestational diabetes mellitus (GDM from Chennai, South India. Materials and Methods: Thirty women with gestational diabetes, 60 age matched controls. Inclusion criteria: Gestational age 22-28 weeks, age group 20-35 years. Exclusion Criteria: Gestational age beyond 28 weeks, malnutrition or presence of infection. Serum chromium was measured using inductive couple plasma emission spectrometer. Results: Serum chromium levels of women with GDM, 1.59+/-0.02 ng/ml (range: 0.16-4.0 ng/ml were lower than in controls (4.58+/-0.62 ng/ml; range 0.82-5.33 ng/ml (P < 0.001. However, there were no significant differences among cases and controls when subdivided by parity. Conclusions: Women with GDM from a South Indian city had lower levels of serum chromium compared to pregnant women without GDM. Studies may be done whether chromium supplementation is useful in this group of women.

  19. Session: Hard Rock Penetration

    Energy Technology Data Exchange (ETDEWEB)

    Tennyson, George P. Jr.; Dunn, James C.; Drumheller, Douglas S.; Glowka, David A.; Lysne, Peter

    1992-01-01

    This session at the Geothermal Energy Program Review X: Geothermal Energy and the Utility Market consisted of five presentations: ''Hard Rock Penetration - Summary'' by George P. Tennyson, Jr.; ''Overview - Hard Rock Penetration'' by James C. Dunn; ''An Overview of Acoustic Telemetry'' by Douglas S. Drumheller; ''Lost Circulation Technology Development Status'' by David A. Glowka; ''Downhole Memory-Logging Tools'' by Peter Lysne.

  20. Hard-hat day

    CERN Multimedia

    2003-01-01

    CERN will be organizing a special information day on Friday, 27th June, designed to promote the wearing of hard hats and ensure that they are worn correctly. A new prevention campaign will also be launched.The event will take place in the hall of the Main Building from 11.30 a.m. to 2.00 p.m., when you will be able to come and try on various models of hard hat, including some of the very latest innovative designs, ask questions and pass on any comments and suggestions.

  1. Accelerated plate tectonics.

    Science.gov (United States)

    Anderson, D L

    1975-03-21

    The concept of a stressed elastic lithospheric plate riding on a viscous asthenosphere is used to calculate the recurrence interval of great earthquakes at convergent plate boundaries, the separation of decoupling and lithospheric earthquakes, and the migration pattern of large earthquakes along an arc. It is proposed that plate motions accelerate after great decoupling earthquakes and that most of the observed plate motions occur during short periods of time, separated by periods of relative quiescence.

  2. Stabilization of chromium salt in ordinary portland cement

    Indian Academy of Sciences (India)

    Ordinary Portland cement (OPC) samples containing the chromium salt have been investigated using differential microcalorimetry, conductometry and Fourier transform infrared spectroscopic analysis. The effect of chromium on OPC hydration was evaluated by continuous observing of early hydration.

  3. Surface Chemistry and Spectroscopy of Chromium in Inorganic Oxides

    NARCIS (Netherlands)

    Weckhuysen, B.M.; Wachs, I.E.; Schoonheydt, R.A.

    1996-01-01

    Focuses on the surface chemistry and spectroscopy of chromium in inorganic oxides. Characterization of the molecular structures of chromium; Mechanics of hydrogenation-dehydrogenation reactions; Mobility and reactivity on oxidic surfaces.

  4. Liquid phase surface nitriding of Ti-6Al-4V pre-placed with chromium

    Energy Technology Data Exchange (ETDEWEB)

    Vahedi Nemani, Alireza, E-mail: alireza_vahedi@ut.ac.ir; Sohi, M. Heydarzadeh; Amadeh, A.A.; Ghaffari, Mahya

    2016-08-01

    In this study, liquid phase surface nitriding of Ti-6Al-4V was carried out by pre-placing of chromium powder on the substrate and subsequent Tungsten Inert Gas (TIG) surface melting. The effect of the application of low and high heat inputs on the microstructure, microhardness and wear resistance of the treated layers were studied. Surface alloying with chromium in a nitrogen containing atmosphere resulted in the formation of hard intermetallic compounds such as TiN, Cr{sub 2}N and TiCr{sub 2}. Moreover, the presence of beta stabilizer chromium together with the application of high heat input during surface treatment resulted in the presence of beta phase at room temperature. However, applying low heat input could not prevent transformation of beta to martensite. The hardness of the layers fabricated at high and low heat inputs were respectively 1050 and 1200 HV{sub 0.3} compared to average 280 HV{sub 0.3} for the as-received material. Liquid phase surface treatment of titanium at the aforementioned conditions improved the wear resistance. The lowest weight loss belonged to the specimen with the beta phase matrix. The formation of the fairly ductile bcc-β phase hindered crack nucleation during wear. The weight loss in this condition was 7 times lower than that of the base material. - Highlights: • Liquid phase surface nitriding of Ti-6Al-4V was carried out by TIG surface melting. • Cr powder was pre-placed on the surface as the beta stabilizer alloying element. • The treated layers were characterized by OM, SEM and X-ray diffraction pattern. • Hardness of the layers increased up to 3 times higher than that of the base alloy. • Liquid phase surface alloying improved the wear resistance.

  5. Create Your Plate

    Medline Plus

    Full Text Available ... Share: Print Page Text Size: A A A Listen En Español Create Your Plate Create Your Plate is a simple and effective way to manage your blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy veggies ...

  6. Chromium in leather footwear - risk assessment of chromium allergy and dermatitis.

    Science.gov (United States)

    Thyssen, Jacob P; Strandesen, Maria; Poulsen, Pia B; Menné, Torkil; Johansen, Jeanne D

    2012-05-01

    Chromium-tanned leather footwear, which releases >3 ppm hexavalent Cr(VI), may pose a risk of sensitizing and eliciting allergic dermatitis. To determine the content and potential release of chromium in leather footwear and to discuss the prevention of chromium contact allergy and dermatitis. Sixty pairs of leather shoes, sandals and boots (20 children's, 20 men's, and 20 women's) were purchased in Copenhagen and examined with X-ray fluorescence spectroscopy. Chromium was extracted according to the International Standard, ISO 17075. The detection level for Cr(VI) was 3 ppm. Chromium was identified in 95% of leather footwear products, the median content being 1.7% (range 0-3.3%). No association with store category or footwear category was found. A tendency for there to be a higher chromium content in footwear with high prices was shown (p(trend) = 0.001). Cr(VI) was extracted from 44% of 18 footwear products, and, in three items, more than 10 ppm was extracted. One shoe had 62 ppm Cr(VI) extracted. Sandals seemed to be over-represented among footwear with detectable Cr(VI). Cr(III) extraction reached a median value of 152 ppm. Most leather footwear contained chromium. Cr(VI) was extracted from a high proportion of leather footwear; this poses a risk of sensitization. © 2012 John Wiley & Sons A/S.

  7. Evaluation of participants' perception and taste thresholds with a zirconia palatal plate.

    Science.gov (United States)

    Wada, Takeshi; Takano, Tomofumi; Tasaka, Akinori; Ueda, Takayuki; Sakurai, Kaoru

    2016-10-01

    Zirconia and cobalt-chromium can withstand a similar degree of loading. Therefore, using a zirconia base for removable dentures could allow the thickness of the palatal area to be reduced similarly to metal base dentures. We hypothesized that zirconia palatal plate for removable dentures provides a high level of participants' perception without influencing taste thresholds. The purpose of this study was to evaluate the participants' perception and taste thresholds of zirconia palatal plate. Palatal plates fabricated using acrylic resin, zirconia, and cobalt-chromium alloy were inserted into healthy individuals. Taste thresholds were investigated using the whole-mouth gustatory test, and participants' perception was evaluated using the 100-mm visual analog scale to assess the ease of pronunciation, ease of swallowing, sensation of temperature, metallic taste, sensation of foreign body, subjective sensory about weight, adhesiveness of chewing gum, and general satisfaction. For the taste thresholds, no significant differences were noted in sweet, salty, sour, bitter, or umami tastes among participants wearing no plate, or the resin, zirconia, and metal plates. Speech was easier and foreign body sensation was lower with the zirconia plate than with the resin plate. Evaluation of the adhesiveness of chewing gum showed that chewing gum does not readily adhere to the zirconia plate in comparison with the metal plate. The comprehensive participants' perception of the zirconia plate was evaluated as being superior to the resin plate. A zirconia palatal plate provides a high level of participants' perception without influencing taste thresholds. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  8. Hexavalent Chromium IV-Free Primer Development

    Science.gov (United States)

    Alldredge, Michael J.; Buck, Amy L.

    2015-01-01

    Primer materials provide corrosion protection for metal parts as well as an increased adhesion between metallic substrates and thermal protection systems (TPSs). Current primers for use in cryogenic applications contain hexavalent chromium. This hexavalent chromium provides excellent corrosion protection even in a cryogenic environment, but it is a carcinogen that requires special equipment and waste control procedures to use. The hazardous nature of hexavalent chromium makes it an obsolescence risk in the future. This study included two phases of evaluation. Thirteen primers were initially identified as candidates and twelve of those primers were tested in phase 1. Four of the best performing candidates from phase 1 continued into phase 2 testing. Phase 1 testing consisted mostly of liquid constituent and physical property testing. Cryoflex and salt fog testing were included in phase 1 because of their importance to the overall success of a candidate material. Phase 2 consisted of physical, thermal, and mechanical properties for nominally processed and fabricated specimens.

  9. Biocompatibility and characterization of a Kolsterised® medical grade cobalt-chromium-molybdenum alloy

    OpenAIRE

    Conti, Malcolm Caligari; Karl, Andreas; Wismayer, Pierre Schembri; Buhagiar, Joseph

    2014-01-01

    High failure rates of cobalt-chromium-molybdenum (Co-Cr-Mo) metal-on-metal hip prosthesis were reported by various authors, probably due to the alloy's limited hardness and tribological properties. This thus caused the popularity of the alloy in metal-on-metal hip replacements to decrease due to its poor wear properties when compared with other systems such as ceramic-on-ceramic. S-phase surface engineering has become an industry standard when citing surface hardening of austenitic stainless ...

  10. Chromium recoil implantation into SAE 1020 steel by nitrogen ion bombardment

    OpenAIRE

    Gomes, G. F.; Ueda, M.; Reuther, H.; Richter, E.; Beloto, A. F.

    2004-01-01

    SAE 1020 is a widely used plain carbon steel, as mortar reinforcement in buildings and small machine parts. But aside from good mechanical properties, its surface suffer from severe corrosion and high wear rate, due to modest hardness. Chromium (Cr) in excess of 12% in Fe alloys renders them resistant to several corrosive attacks. So we tried to introduce Cr in such amounts into the surface of that steel. Cr films were deposited by electron beam on SAE 1020 steel. Bombarding the Cr film eithe...

  11. Hardness and excitation energy

    Indian Academy of Sciences (India)

    It is shown that the first excitation energy can be given by the Kohn-Sham hardness (i.e. the energy difference of the ground-state lowest unoccupied and highest occupied levels) plus an extra term coming from the partial derivative of the ensemble exchange-correlation energy with respect to the weighting factor in the ...

  12. Hard Probes at ATLAS

    CERN Document Server

    Citron, Z; The ATLAS collaboration

    2014-01-01

    The ATLAS collaboration has measured several hard probe observables in Pb+Pb and p+Pb collisions at the LHC. These measurements include jets which show modification in the hot dense medium of heavy ion collisions as well as color neutral electro-weak bosons. Together, they elucidate the nature of heavy ion collisions.

  13. Hardness of metallic crystals

    Indian Academy of Sciences (India)

    Administrator

    where H is the hardness, k the coefficient, G the shear modulus, ν the Poisson's ratio, η a function of the radius of an atom (r) and the electron density at the atom interface (n). The formula will not only be used to testify the critical grain size with stable dislocations, but also play an important role in the understanding of ...

  14. Running in Hard Times

    Science.gov (United States)

    Berry, John N., III

    2009-01-01

    Roberta Stevens and Kent Oliver are campaigning hard for the presidency of the American Library Association (ALA). Stevens is outreach projects and partnerships officer at the Library of Congress. Oliver is executive director of the Stark County District Library in Canton, Ohio. They have debated, discussed, and posted web sites, Facebook pages,…

  15. CSI: Hard Drive

    Science.gov (United States)

    Sturgeon, Julie

    2008-01-01

    Acting on information from students who reported seeing a classmate looking at inappropriate material on a school computer, school officials used forensics software to plunge the depths of the PC's hard drive, searching for evidence of improper activity. Images were found in a deleted Internet Explorer cache as well as deleted file space.…

  16. Hard and Soft Governance

    DEFF Research Database (Denmark)

    Moos, Lejf

    2009-01-01

    The governance and leadership at transnational, national and school level seem to be converging into a number of isomorphic forms as we see a tendency towards substituting 'hard' forms of governance, that are legally binding, with 'soft' forms based on persuasion and advice. This article analyses...

  17. Hardness and excitation energy

    Indian Academy of Sciences (India)

    Unknown

    form a new species leading to a single electronegativity or chemical potential (the same way as in ordinary thermodynamics). The hardness η of an electronic system is ..... Technological Innovation Foundation and the Minis- try of Science and Technology. This work was also supported by the grant OTKA No. T042505.

  18. Mössbauer and magnetization studies of nanosize chromium ferrite

    African Journals Online (AJOL)

    user

    In spite of this much magnetization in the chromium ferrite nanoparticles, no hyperfine ... Iron, chromium and oxygen form a stable oxide FeCr2O4 known as iron chromite. ... Nanosize chromium ferrites in the size range of 6 to 35 nm were synthesized by .... As we know in zinc ferrite the magnetization appears due to cationic ...

  19. Hexavalent and trivalent chromium in leather: What should be done?

    Science.gov (United States)

    Moretto, Angelo

    2015-11-01

    Trivalent chromium compounds are used for leather tanning, and chromium may be released during use of leather goods. In certain instances, small amounts of hexavalent chromium can be formed and released. Both trivalent and hexavalent chromium can elicit allergic skin reaction in chromium sensitised subjects, the latter being significantly more potent. Induction of sensitisation only occurs after exposure to hexavalent chromium. A minority of subjects are sensitised to chromium, and in a fraction of these subjects allergic skin reaction have been described after wearing leather shoes or, less frequently, other leather goods. The evidence that in all these cases the reaction is related to hexavalent chromium is not always strong. The content of hexavalent chromium in leather is regulated in European Union, but rate of release rather than content is relevant for allergic skin reaction. The role of trivalent chromium appear much less relevant if at all. Modern tanning procedure do not pose significant risk due to either hexavalent or trivalent chromium. Dismissing bad quality and worn-off leather goods is relevant in reducing or eliminating the skin reaction. It should also be pointed out that shoe components or substances other than chromium in leather may cause allergic/irritative skin reactions. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Levels of Lead, Cadmium and Chromium in Oreochromis Niloticus ...

    African Journals Online (AJOL)

    Lead (Pb), Cadmium (Cd) and Chromium (Cr) levels in Oreochromis niloticus, aquatic plants, water and sawdust were collected and analyzed for Lead, Cadmium and Chromium using atomic absorption spectroscopy. Results obtained showed that sawdust had the highest Lead and Chromium contents of 32.0 + 0.99 μg/g ...

  1. Thermodynamic properties of chromium bearing slags and minerals. A review

    Energy Technology Data Exchange (ETDEWEB)

    Xiao Yanping; Holappa, L.

    1996-12-31

    In this report, the thermodynamic properties of chromium bearing slags and minerals were reviewed based on the available information in the literature. It includes the analysing methods for oxidation state of chromium in slags, oxidation state of chromium and activities of chromium oxides in slags and minerals. The phase diagrams of chromium oxide systems and chromium distributions between slag and metal phases are also covered ill this review. Concerning the analysing methods, it was found that most of the available approaches are limited to iron free slag systems and the sample preparation is very sensitive to the analysing results. In silicate slags under reducing atmosphere, divalent and trivalent chromium co-exist in the slags. It is agreed that the fraction of divalent chromium to total chromium increases with higher temperature, lower slag basicity and oxygen potential. For the slags under oxidising atmosphere, trivalent, pentavalent and hexavalent states were reported to be stable. The activities of CrO and CrO{sub 1.5} were concluded to have positive deviation from ideal solution. Slag basicity has a positive effect and temperature has a negative effect on the activities of chromium oxides. The phase diagrams of the Cr-O, binary, and ternary chromium containing oxide systems have been examined systematically. The analysis shows that the data on the quaternary and quinary systems are insufficient, and require further investigation. The most important features of the chromium containing silicate slags are the large miscibility gaps and the stability of the chromite spinel. (orig.) (76 refs.)

  2. Assessment of the level of chromium species in the discharged ...

    African Journals Online (AJOL)

    The purpose of this study was to assess the level of chromium species in the discharged effluents of selected tanneries in the Amhara Region; Haik and Debre Berhan tanneries. The level of total chromium, and hexavalent chromium in the discharged effluent of the studied tanneries were determined using the ICP-OES, and ...

  3. 21 CFR 73.2326 - Chromium hydroxide green.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Chromium hydroxide green. 73.2326 Section 73.2326... COLOR ADDITIVES EXEMPT FROM CERTIFICATION Cosmetics § 73.2326 Chromium hydroxide green. (a) Identity and specifications.The color additive chromium hydroxide green shall conform in identity and specifications to the...

  4. 21 CFR 73.1327 - Chromium oxide greens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Chromium oxide greens. 73.1327 Section 73.1327... COLOR ADDITIVES EXEMPT FROM CERTIFICATION Drugs § 73.1327 Chromium oxide greens. (a) Identity. (1) The color additive chromium oxide greens is principally chromic sesquioxide (Cr2O3). (2) Color additive...

  5. 21 CFR 73.1326 - Chromium hydroxide green.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Chromium hydroxide green. 73.1326 Section 73.1326... COLOR ADDITIVES EXEMPT FROM CERTIFICATION Drugs § 73.1326 Chromium hydroxide green. (a) Identity. (1) The color additive chromium hydroxide green is principally hydrated chromic sesquioxide (Cr2O3·XH2O...

  6. 21 CFR 73.2327 - Chromium oxide greens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Chromium oxide greens. 73.2327 Section 73.2327... COLOR ADDITIVES EXEMPT FROM CERTIFICATION Cosmetics § 73.2327 Chromium oxide greens. (a) Identity and specifications. The color additive chromium oxide greens shall conform in identify and specifications to the...

  7. 21 CFR 73.3111 - Chromium oxide greens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Chromium oxide greens. 73.3111 Section 73.3111... COLOR ADDITIVES EXEMPT FROM CERTIFICATION Medical Devices § 73.3111 Chromium oxide greens. (a) Identity and specifications. The color additive chromium oxide greens (chromic oxide) (CAS Reg. No. 1308-38-9...

  8. 75 FR 67100 - Superalloy Degassed Chromium From Japan

    Science.gov (United States)

    2010-11-01

    ... COMMISSION Superalloy Degassed Chromium From Japan AGENCY: United States International Trade Commission... chromium from Japan. SUMMARY: The Commission hereby gives notice that it has instituted a review pursuant... revocation of the antidumping duty order on superalloy degassed chromium from Japan would be likely to lead...

  9. Native Chromium Resistant Staphylococci Species from a Fly Ash ...

    African Journals Online (AJOL)

    Sixty-six chromium-resistant Staphylococci species belonging to S. epidermidis, S. aureus, S. saprophyticus and S. arlettae were previously isolated from a chromium-polluted Fly ash (FA) dumping site in South Africa. However the genetic mechanisms responsible for chromium resistance were not known. Polymerase chain ...

  10. ELECTROSLAG CАSTING OF CHROMIUM BASED ALLOYS

    Directory of Open Access Journals (Sweden)

    Jong-Hoon Lee

    2015-01-01

    Full Text Available The analysis of the electroslag remelting (ESR process schemes was carried out. For heat-resistant material on the basis of chromium chosen scheme crucible ESR with nonconsumable bifilar electrodes. Developed and manufactured laboratory plant for studying the processes of electroslag remelting crucible chromium-based alloys. Samples from chromium based alloy were obtained.

  11. Impact of the nanostructuration on the corrosion resistance and hardness of irradiated 316 austenitic stainless steels

    Energy Technology Data Exchange (ETDEWEB)

    Hug, E., E-mail: eric.hug@ensicaen.fr [Laboratoire de Cristallographie et Sciences des Matériaux, Normandie Université, CNRS UMR 6508, 6 Bd Maréchal Juin, 14050 Caen (France); Prasath Babu, R. [School of Materials, University of Manchester, M13 9PL (United Kingdom); Groupe de Physique des Matériaux, UMR CNRS 6634, Université et INSA de Rouen, Normandie Université, Saint-Etienne du Rouvray Cedex (France); Monnet, I. [Centre de recherches sur les Ions, les Matériaux et la Photonique CEA-CNRS, Normandie Université, 6 Bd Maréchal Juin, 14050 Caen (France); Etienne, A. [Groupe de Physique des Matériaux, UMR CNRS 6634, Université et INSA de Rouen, Normandie Université, Saint-Etienne du Rouvray Cedex (France); Moisy, F. [Centre de recherches sur les Ions, les Matériaux et la Photonique CEA-CNRS, Normandie Université, 6 Bd Maréchal Juin, 14050 Caen (France); Pralong, V. [Laboratoire de Cristallographie et Sciences des Matériaux, Normandie Université, CNRS UMR 6508, 6 Bd Maréchal Juin, 14050 Caen (France); Enikeev, N. [Institute of Physics of Advanced Materials, Ufa (Russian Federation); Saint Petersburg State University, Laboratory of the Mechanics of Bulk Nanostructured Materials, 198504 St. Petersburg (Russian Federation); Abramova, M. [Institute of Physics of Advanced Materials, Ufa (Russian Federation); and others

    2017-01-15

    Highlights: • Impacts of nanostructuration and irradiation on the properties of 316 stainless steels are reported. • Irradiation of nanostructured samples implies chromium depletion as than depicted in coarse grain specimens. • Hardness of nanocrystalline steels is only weakly affected by irradiation. • Corrosion resistance of the nanostructured and irradiated samples is less affected by the chromium depletion. - Abstract: The influence of grain size and irradiation defects on the mechanical behavior and the corrosion resistance of a 316 stainless steel have been investigated. Nanostructured samples were obtained by severe plastic deformation using high pressure torsion. Both coarse grain and nanostructured samples were irradiated with 10 MeV {sup 56}Fe{sup 5+} ions. Microstructures were characterized using transmission electron microscopy and atom probe tomography. Surface mechanical properties were evaluated thanks to hardness measurements and the corrosion resistance was studied in chloride environment. Nanostructuration by high pressure torsion followed by annealing leads to enrichment in chromium at grain boundaries. However, irradiation of nanostructured samples implies a chromium depletion of the same order than depicted in coarse grain specimens but without metallurgical damage like segregated dislocation loops or clusters. Potentiodynamic polarization tests highlight a definitive deterioration of the corrosion resistance of coarse grain steel with irradiation. Downsizing the grain to a few hundred of nanometers enhances the corrosion resistance of irradiated samples, despite the fact that the hardness of nanocrystalline austenitic steel is only weakly affected by irradiation. These new experimental results are discussed in the basis of couplings between mechanical and electrical properties of the passivated layer thanks to impedance spectroscopy measurements, hardness properties of the surfaces and local microstructure evolutions.

  12. Strategies for chromium bioremediation of tannery effluent.

    Science.gov (United States)

    Garg, Satyendra Kumar; Tripathi, Manikant; Srinath, Thiruneelakantan

    2012-01-01

    Bioremediation offers the possibility of using living organisms (bacteria, fungi, algae,or plants), but primarily microorganisms, to degrade or remove environmental contaminants, and transform them into nontoxic or less-toxic forms. The major advantages of bioremediation over conventional physicochemical and biological treatment methods include low cost, good efficiency, minimization of chemicals, reduced quantity of secondary sludge, regeneration of cell biomass, and the possibility of recover-ing pollutant metals. Leather industries, which extensively employ chromium compounds in the tanning process, discharge spent-chromium-laden effluent into nearby water bodies. Worldwide, chromium is known to be one of the most common inorganic contaminants of groundwater at pollutant hazardous sites. Hexavalent chromium poses a health risk to all forms of life. Bioremediation of chromium extant in tannery waste involves different strategies that include biosorption, bioaccumulation,bioreduction, and immobilization of biomaterial(s). Biosorption is a nondirected physiochemical interaction that occurs between metal species and the cellular components of biological species. It is metabolism-dependent when living biomass is employed, and metabolism-independent in dead cell biomass. Dead cell biomass is much more effective than living cell biomass at biosorping heavy metals, including chromium. Bioaccumulation is a metabolically active process in living organisms that works through adsorption, intracellular accumulation, and bioprecipitation mechanisms. In bioreduction processes, microorganisms alter the oxidation/reduction state of toxic metals through direct or indirect biological and chemical process(es).Bioreduction of Cr6+ to Cr3+ not only decreases the chromium toxicity to living organisms, but also helps precipitate chromium at a neutral pH for further physical removal,thus offering promise as a bioremediation strategy. However, biosorption, bioaccumulation, and

  13. Geologically current plate motions

    Science.gov (United States)

    DeMets, Charles; Gordon, Richard G.; Argus, Donald F.

    2010-04-01

    We describe best-fitting angular velocities and MORVEL, a new closure-enforced set of angular velocities for the geologically current motions of 25 tectonic plates that collectively occupy 97 per cent of Earth's surface. Seafloor spreading rates and fault azimuths are used to determine the motions of 19 plates bordered by mid-ocean ridges, including all the major plates. Six smaller plates with little or no connection to the mid-ocean ridges are linked to MORVEL with GPS station velocities and azimuthal data. By design, almost no kinematic information is exchanged between the geologically determined and geodetically constrained subsets of the global circuit-MORVEL thus averages motion over geological intervals for all the major plates. Plate geometry changes relative to NUVEL-1A include the incorporation of Nubia, Lwandle and Somalia plates for the former Africa plate, Capricorn, Australia and Macquarie plates for the former Australia plate, and Sur and South America plates for the former South America plate. MORVEL also includes Amur, Philippine Sea, Sundaland and Yangtze plates, making it more useful than NUVEL-1A for studies of deformation in Asia and the western Pacific. Seafloor spreading rates are estimated over the past 0.78 Myr for intermediate and fast spreading centres and since 3.16 Ma for slow and ultraslow spreading centres. Rates are adjusted downward by 0.6-2.6mmyr-1 to compensate for the several kilometre width of magnetic reversal zones. Nearly all the NUVEL-1A angular velocities differ significantly from the MORVEL angular velocities. The many new data, revised plate geometries, and correction for outward displacement thus significantly modify our knowledge of geologically current plate motions. MORVEL indicates significantly slower 0.78-Myr-average motion across the Nazca-Antarctic and Nazca-Pacific boundaries than does NUVEL-1A, consistent with a progressive slowdown in the eastward component of Nazca plate motion since 3.16 Ma. It also

  14. Hardness and Wear Resistance of TiC-Fe-Cr Locally Reinforcement Produced in Cast Steel

    Directory of Open Access Journals (Sweden)

    Olejnik E.

    2016-06-01

    Full Text Available In order to increase wear resistance cast steel casting the TiC-Fe-Cr type composite zones were fabricated. These zones were obtained by means of in situ synthesis of substrates of the reaction TiC with a moderator of a chemical composition of white cast iron with nickel of the Ni-Hard type 4. The synthesis was carried out directly in the mould cavity. The moderator was applied to control the reactive infiltration occurring during the TiC synthesis. The microstructure of composite zones was investigated by electron scanning microscopy, using the backscattered electron mode. The structure of composite zones was verified by the X-ray diffraction method. The hardness of composite zones, cast steel base alloy and the reference samples such as white chromium cast iron with 14 % Cr and 20 % Cr, manganese cast steel 18 % Mn was measured by Vickers test. The wear resistance of the composite zone and the reference samples examined by ball-on-disc wear test. Dimensionally stable composite zones were obtained containing submicron sizes TiC particles uniformly distributed in the matrix. The macro and microstructure of the composite zone ensured three times hardness increase in comparison to the cast steel base alloy and one and a half times increase in comparison to the white chromium cast iron 20 % Cr. Finally ball-on-disc wear rate of the composite zone was five times lower than chromium white cast iron containing 20 % Cr.

  15. Leaching of chromium from chromium contaminated soil: Speciation study and geochemical modeling

    National Research Council Canada - National Science Library

    Anđelković Darko H; Anđelković Tatjana D; Nikolić Ružica S; Purenović Milovan M; Blagojević Srđan D; Bojić Aleksandar Lj; Ristić Milica M

    2012-01-01

    Distribution of chromium between soil and leachate was monitored. A natural process of percolating rainwater through the soil was simulated in the laboratory conditions and studied with column leaching extraction...

  16. Mechanical properties of metal-ceramic systems from nickel-chromium and cobalt-chromium alloys

    National Research Council Canada - National Science Library

    Mirković, Nemanja

    2007-01-01

    .... The aim of this study was to evaluate metal-ceramic bond strenght and elastic modulus of cobalt-chromium alloys in making porcelain-fused-to-metal restorations, regarding the application of the most...

  17. Mechanical properties of metal-ceramic systems from nickel-chromium and cobalt-chromium alloys

    National Research Council Canada - National Science Library

    Mirkovic, Nemanja

    2007-01-01

    .... The aim of this study was to evaluate metal-ceramic bond strength and elastic modulus of cobalt-chromium alloys in making porcelainfused- to-metal restorations, regarding the application of the most...

  18. Chromium allergy and dermatitis: prevalence and main findings

    DEFF Research Database (Denmark)

    Bregnbak, David; Johansen, Jeanne D.; Jellesen, Morten Stendahl

    2015-01-01

    The history of chromium as an allergen goes back more than a century, and includesan interventional success with national legislation that led to significant changes inthe epidemiology of chromium allergy in construction workers. The 2015 EU Leather Regulation once again put a focus on chromium...... allergy, emphasizing that the investigation of chromium allergy is still far from complete. Our review article on chromium focuses on the allergen’s chemical properties, its potential exposure sources, and the allergen’s interaction with the skin, and also provides an overview of the regulations...

  19. Chromium-modified a-C films with advanced structural, mechanical and corrosive-resistant characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Ming, Miao Yi [International Chinese-Belarusian scientific laboratory on vacuum-plasma technology, Nanjing University of Science and Technology, Nanjing 210094 (China); Francisk Skorina Gomel State University, Gomel 246019 (Belarus); Jiang, Xiaohong, E-mail: jxh0668@sina.com [International Chinese-Belarusian scientific laboratory on vacuum-plasma technology, Nanjing University of Science and Technology, Nanjing 210094 (China); Francisk Skorina Gomel State University, Gomel 246019 (Belarus); Piliptsou, D.G., E-mail: pdg_@mail.ru [International Chinese-Belarusian scientific laboratory on vacuum-plasma technology, Nanjing University of Science and Technology, Nanjing 210094 (China); Francisk Skorina Gomel State University, Gomel 246019 (Belarus); Zhuang, Yuzhao; Rogachev, A.V.; Rudenkov, A.S. [International Chinese-Belarusian scientific laboratory on vacuum-plasma technology, Nanjing University of Science and Technology, Nanjing 210094 (China); Francisk Skorina Gomel State University, Gomel 246019 (Belarus); Balmakou, A. [Faculty of Material Science and Technology, Slovak University of Technology, Trnava 91724 (Slovakia)

    2016-08-30

    Highlights: • Influence of the chromium interlayer on the structure and mechanical properties of a-C:Cr films. • Residual stress and wear of a-C:Cr and Cr/a-C varies due to their phase and surface morphology. • Chromium-modified a-C films with advanced structural, mechanical and corrosive-resistant characteristics. - Abstract: To improve structural, mechanical and chemical properties of diamond-like carbon films, we developed amorphous carbon chromium-modified composite films fabricated by means of cathode magnetic filtered arc deposition. The properties were analyzed by Raman spectroscopy, X-ray photoelectron spectroscopy and atomic force microscopy for the purpose of the structure characterization, elemental analysis and topology examination. Moreover, we also assessed residual stress, the coefficient of friction, hardness, the elastic modulus and corrosion parameters through X-ray double-crystal surface profilometry, tribo-testing, nanoindenter-testing, as well as contact angle measurements and potentiodynamic polarization analysis. As a result of a comparative analysis, we revealed a substantial improvement in the characteristics of developed composite films in comparison with amorphous carbon films. For example, Cr-modification is resulted, in greater integrated performance, toughness and corrosion resistance; the residual stress was reduced substantially.

  20. Mechanical properties of metal-ceramic systems from nickel-chromium and cobalt-chromium alloys

    OpenAIRE

    Mirković Nemanja

    2007-01-01

    Background/Aim. Metal-ceramic bond strength and alloys' elastic modulus clearly determine the potential of alloy application, because the ceramic integrity during mastication depends on these two characteristics. The aim of this study was to evaluate metal-ceramic bond strength and elastic modulus of cobalt-chromium alloys in making porcelainfused- to-metal restorations, regarding the application of the most frequent nickel-chromium alloy. Methods. The research was performed as an experimenta...

  1. [Evaluation of bond strength between low fusing porcelain with goldplated cobalt-chromium alloys].

    Science.gov (United States)

    Guo, Jing; Zhu, Jia; Zhu, Hong-shui

    2014-02-01

    To evaluate the bond strength of Vita OMEGA 900 low fusing porcelain fused with the goldplated Wirobond cobalt-chrome metalt ceramic alloy. Low fusing porcelain was fused with the cobalt-chromium alloy strips(group A) and the goldplated cobalt-chromium alloy strips(group B) respectively according to ISO9693 (A:8,B:10). 8 specimens of each group were submitted to three point bending test. Two more test pieces fused with gold plated cobalt-chromium alloys were made (group B'). One test piece of both group B and group B' were observed under scanning electron microscope (SEM) randomly. The data was analyzed with SPSS 16.0 software package. The bond strength (MPa) of group A and group B was 29.92±4.28 and 28.20±5.21, respectively (P>0.05), both higher than 25 MPa required by ISO9693. SEM showed that Vita OMEGA 900 low fusing porcelain and the goldplated Wirobond cobalt-chrome metalt ceramic alloy combined together closely without cracks. Much gold was fused to the cobalt-chrome alloy surface of breaking porcelain specimen after testing. Vita OMEGA 900 low fusing porcelain can match with the goldplated Wirobond cobalt-chrome metalt ceramic alloy. Supported by Foundation of Education Department of Jiangxi Province (GJJ10367).

  2. SUPER HARD SURFACED POLYMERS

    Energy Technology Data Exchange (ETDEWEB)

    Mansur, Louis K [ORNL; Bhattacharya, R [UES, Incorporated, Dayton, OH; Blau, Peter Julian [ORNL; Clemons, Art [ORNL; Eberle, Cliff [ORNL; Evans, H B [UES, Incorporated, Dayton, OH; Janke, Christopher James [ORNL; Jolly, Brian C [ORNL; Lee, E H [Consultant, Milpitas, CA; Leonard, Keith J [ORNL; Trejo, Rosa M [ORNL; Rivard, John D [ORNL

    2010-01-01

    High energy ion beam surface treatments were applied to a selected group of polymers. Of the six materials in the present study, four were thermoplastics (polycarbonate, polyethylene, polyethylene terephthalate, and polystyrene) and two were thermosets (epoxy and polyimide). The particular epoxy evaluated in this work is one of the resins used in formulating fiber reinforced composites for military helicopter blades. Measures of mechanical properties of the near surface regions were obtained by nanoindentation hardness and pin on disk wear. Attempts were also made to measure erosion resistance by particle impact. All materials were hardness tested. Pristine materials were very soft, having values in the range of approximately 0.1 to 0.5 GPa. Ion beam treatment increased hardness by up to 50 times compared to untreated materials. For reference, all materials were hardened to values higher than those typical of stainless steels. Wear tests were carried out on three of the materials, PET, PI and epoxy. On the ion beam treated epoxy no wear could be detected, whereas the untreated material showed significant wear.

  3. Hard Probes at RHIC

    Directory of Open Access Journals (Sweden)

    Bielčíková Jana

    2014-04-01

    Full Text Available Measurements of jets and heavy flavour, the so called hard probes, play a crucial role in understanding properties of hot and dense nuclear matter created in high energy heavy-ion collisions. The measurements at the Relativistic Heavy Ion Collider (RHIC showed that in central Au+Au collisons at RHIC energy ( √sNN = 200 GeV the nuclear matter created has properties close to those of perfect liquid, manifests partonic degrees of freedom and is opaque to hard probes. In order to draw quantitative conclusions on properties of this hot and dense nuclear matter reference measurements in proton-proton collisions and d+Au collisions are essential to estimate cold nuclear matter effects. In this proceedings a review of recent results on hard probes measurements in p+p, d+Au and A+A collisions as well as of beam energy dependence of jet quenching from STAR and PHENIX experiments at RHIC is presented.

  4. Extraction Of Chromium From Leather Chrome Shaving Dust.

    Directory of Open Access Journals (Sweden)

    Ashiqur Rahaman

    2015-08-01

    Full Text Available Leather processing involves transformation of putrescible animal hides and skin into non putrescible leather. Leather industry generates a huge amount of solid waste containing chromium. These solid wastes were disposed of through land filling which causes leaching out of in soil and water. Now a day increasing environmental legislations have encouraged tannery industry to develop a new technology. In this study we incinerated chrome shaving dust at 500oC to 7000C for chromium extraction. Various oxidizing acids with different concentration were used for chromium extraction. Extracted chromium was measured by Atomic Absorption Spectrometry. Recovery of chromium was in the range of 297 mgL to 222 mgL. Nitric acid extracted maximum amount of chromium while sulfuric acid extracted minimum amount of chromium.

  5. BIOSORPTION OF CHROMIUM (VI) USING IMMOBILIZED ...

    African Journals Online (AJOL)

    USER

    2016-05-20

    May 20, 2016 ... water and air. It affects the growth of flora and fauna which in turn affect human health negatively. Chromium could also bio-accumulate in plants and animals and this becomes ... The sorption kinetic models of Cr (VI) onto the biosorbents were examined with ... bulk density, moisture and ash contents.

  6. The electronic structure of antiferromagnetic chromium

    DEFF Research Database (Denmark)

    Skriver, Hans Lomholt

    1981-01-01

    The author has used the local spin density formalism to perform self-consistent calculations of the electronic structure of chromium in the non-magnetic and commensurate antiferromagnetic phases, as a function of the lattice parameter. A change of a few per cent in the atomic radius brings...

  7. The fate of chromium during tropical weathering

    DEFF Research Database (Denmark)

    Berger, Alfons; Frei, Robert

    2014-01-01

    We performed a mineral, geochemical and Cr–Sr–Pb isotope study on a laterite profile developed on ca. 540 Ma old tonalitic bedrock in Madagascar with special emphasis on the behavior of chromium during tropical weathering. The observed strong depletions of Ca, Si, and P, and enrichment of Fe and Al...

  8. Defect structure of electrodeposited chromium layers

    CERN Document Server

    Marek, T; Vertes, A; El-Sharif, M; McDougall, J; Chisolm, C U

    2000-01-01

    Positron annihilation spectroscopy was applied to study the effects of pre-treatment and composition of substrates on the quality and defect structure of electrodeposited thick chromium coatings. The results show that both parameters are important, and a scenario is proposed why the mechanically polished substrate gives more defective film than the electro polished one.

  9. Thermodynamic Properties of Chromium Adsorption by Sediments ...

    African Journals Online (AJOL)

    MBI

    2013-06-19

    Jun 19, 2013 ... Department of Pure and Industrial Chemistry, Bayero University, PMB 3011, Kano, Nigeria. Email: ladanmagaji@yahoo.com ... quantify the processes governing the interactions of various solutes with soils (Amacher et. ... industrial effluent using removal of chromium from electroplating industry effluents by.

  10. Chromium Tolerance and Bioremoval by Cyanobacteria Isolated ...

    African Journals Online (AJOL)

    Two cyanobacterial species Nostoc calcicola HH-12 and Chroococcus minutus HH-11 isolated from a textile mill oxidation pond were examined individually and as consortium for their chromium(VI) tolerance and bioremoval from aqueous solutions. Both species were tolerant to the metal and showed significant increase ...

  11. Iron-based alloy and nitridation treatment for PEM fuel cell bipolar plates

    Science.gov (United States)

    Brady, Michael P [Oak Ridge, TN; Yang, Bing [Oak Ridge, TN; Maziasz, Philip J [Oak Ridge, TN

    2010-11-09

    A corrosion resistant electrically conductive component that can be used as a bipolar plate in a PEM fuel cell application is composed of an alloy substrate which has 10-30 wt. % Cr, 0.5 to 7 wt. % V, and base metal being Fe, and a continuous surface layer of chromium nitride and vanadium nitride essentially free of base metal. A oxide layer of chromium vanadium oxide can be disposed between the alloy substrate and the continuous surface nitride layer. A method to prepare the corrosion resistant electrically conductive component involves a two-step nitridization sequence by exposing the alloy to a oxygen containing gas at an elevated temperature, and subsequently exposing the alloy to an oxygen free nitrogen containing gas at an elevated temperature to yield a component where a continuous chromium nitride layer free of iron has formed at the surface.

  12. Biocompatibility and characterization of a Kolsterised(®) medical grade cobalt-chromium-molybdenum alloy.

    Science.gov (United States)

    Conti, Malcolm Caligari; Karl, Andreas; Wismayer, Pierre Schembri; Buhagiar, Joseph

    2014-01-01

    High failure rates of cobalt-chromium-molybdenum (Co-Cr-Mo) metal-on-metal hip prosthesis were reported by various authors, probably due to the alloy's limited hardness and tribological properties. This thus caused the popularity of the alloy in metal-on-metal hip replacements to decrease due to its poor wear properties when compared with other systems such as ceramic-on-ceramic. S-phase surface engineering has become an industry standard when citing surface hardening of austenitic stainless steels. This hardening process allows the austenitic stainless steel to retain its corrosion resistance, while at the same time also improving its hardness and wear resistance. By coupling S-phase surface engineering, using the proprietary Kolsterising(®) treatment from Bodycote Hardiff GmbH, that is currently being used mainly on stainless steel, with Co-Cr-Mo alloys, an improvement in hardness and tribological characteristics is predicted. The objective of this paper is to analyze the biocompatibility of a Kolsterised(®) Co-Cr-Mo alloy, and to characterize the material surface in order to show the advantages gained by using the Kolsterised(®) material relative to the original untreated alloy, and other materials. This work has been performed on 3 fronts including; Material characterization, "In-vitro" corrosion testing, and Biological testing conforming to BS EN ISO 10993-18:2009 - Biological evaluation of medical devices. Using these techniques, the Kolsterised(®) cobalt-chromium-molybdenum alloys were found to have good biocompatibility and an augmented corrosion resistance when compared with the untreated alloy. The Kolsterised(®) samples also showed a 150% increase in surface hardness over the untreated material thus predicting better wear properties.

  13. Biocompatibility and characterization of a Kolsterised® medical grade cobalt-chromium-molybdenum alloy

    Science.gov (United States)

    Conti, Malcolm Caligari; Karl, Andreas; Wismayer, Pierre Schembri; Buhagiar, Joseph

    2014-01-01

    High failure rates of cobalt-chromium-molybdenum (Co-Cr-Mo) metal-on-metal hip prosthesis were reported by various authors, probably due to the alloy's limited hardness and tribological properties. This thus caused the popularity of the alloy in metal-on-metal hip replacements to decrease due to its poor wear properties when compared with other systems such as ceramic-on-ceramic. S-phase surface engineering has become an industry standard when citing surface hardening of austenitic stainless steels. This hardening process allows the austenitic stainless steel to retain its corrosion resistance, while at the same time also improving its hardness and wear resistance. By coupling S-phase surface engineering, using the proprietary Kolsterising® treatment from Bodycote Hardiff GmbH, that is currently being used mainly on stainless steel, with Co-Cr-Mo alloys, an improvement in hardness and tribological characteristics is predicted. The objective of this paper is to analyze the biocompatibility of a Kolsterised® Co-Cr-Mo alloy, and to characterize the material surface in order to show the advantages gained by using the Kolsterised® material relative to the original untreated alloy, and other materials. This work has been performed on 3 fronts including; Material characterization, “In-vitro” corrosion testing, and Biological testing conforming to BS EN ISO 10993–18:2009 - Biological evaluation of medical devices. Using these techniques, the Kolsterised® cobalt-chromium-molybdenum alloys were found to have good biocompatibility and an augmented corrosion resistance when compared with the untreated alloy. The Kolsterised® samples also showed a 150% increase in surface hardness over the untreated material thus predicting better wear properties. PMID:24451266

  14. Study on fragmentation and dissolution behavior of carbide in a hot-rolled hypereutectic high chromium cast iron

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Fei; Jiang, Yehua, E-mail: jiangyehua@kmust.edu.cn; Xiao, Han; Tan, Jun

    2015-01-05

    Highlights: • The method to prepare Carbon steel/High chromium iron is totally new. • High chromium iron can achieve small plastic deformation during hot rolling process. • Carbides in high chromium irons are crushed, refined obviously and becoming isolated, which is benefit to improve the impact toughness. • The carbide fragmentation and dissolution behavior of the hot-rolled HCCI were analyzed. - Abstract: A sandwich-structured composite containing a hypereutectic high chromium cast iron (HCCI) and low carbon steel (LCS) claddings was newly fabricated by centrifugal casting, then the blank was hot-rolled into composite plate. The carbide fragmentation and dissolution behavior of the hot-rolled HCCI were analyzed. During hot rolling, significant refinement of carbides was discovered in hot-rolled HCCI specimens. The carbides were broken and partly dissolved into the austenite matrix. The results show that carbides are firstly dissolved under the action of stress. There are grooves appeared at the boundaries of the carbides. The grooves reduce the cross section of the carbide. When the cross section of the carbide reaches to the required minimum critical cross section, the carbide breaks through the tensile force. After break, carbides continue to dissolve since more interfaces between the matrix and carbides are generated. The secondary carbides precipitated due to the dissolution are index as fcc and stacking faults parallel to the {1 1 1} are observed.

  15. Chitosan supramolecularly cross linked with trimesic acid - Facile synthesis, characterization and evaluation of adsorption potential for chromium(VI).

    Science.gov (United States)

    Bhatt, Ronak; Sreedhar, B; Padmaja, P

    2017-11-01

    A facile synthesis of Chitosan Supramolecularly cross-linked with Trimesic Acid (CTMA) is reported in this work. The adsorption potential of CTMA for removal of hexavalent chromium was evaluated and the influence of pH, temperature, contact time and adsorbent dose on the adsorption process was investigated. The experimental results showed that CTMA could efficiently adsorb Cr(6+) and partially reduce it to the less toxic Cr(3+) state. The maximum adsorption capacity of CTMA for Cr(6+) was found to be 129.53mg/g at pH 2.0. CTMA and chromium loaded CTMA were characterised by FT-IR, Raman, TGA-DSC, SEM-EDX, XRD, ESR and XPS spectroscopic techniques. Chitosan was observed to be cross- linked with TMA via ionic, hydrogen bonding and pi-pi supramolecular interactions while adsorption of chromium onto CTMA was by electrostatic forces and hydrogen bonding. From the observed results it was evident that CTMA was successfully applied for simultaneous removal of chromium, lead and iron from chrome plating effluent. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Enhancement of surface properties of SAE 1020 by chromium plasma immersion recoil implantation

    Science.gov (United States)

    Ueda, M.; Mello, C. B.; Beloto, A. F.; Rossi, J. O.; Reuther, H.

    2007-04-01

    SAE 1020 steel is commonly used as concrete reinforcement and small machine parts, but despite its good mechanical properties, as ductility, hardness and wear resistance, it is susceptible to severe corrosion. It is well known that chromium content above 12% in Fe alloys increases their corrosion resistance. In order to obtain this improvement, we studied the introduction of chromium atoms into the matrix of SAE 1020 steel by recoil implantation process using a plasma immersion ion implantation (PIII) system. Potentiodynamic scans showed that the presence of Cr film leads to a gain in the corrosion potential, from -650 mV to -400 mV. After PIII treatment, the corrosion potential increased further to -340 mV, but the corrosion current density presented no significant change. Vickers microhardness tests showed surface hardness increase of up to about 27% for the treated samples. Auger electron spectroscopy showed that, for a 30 nm film, Cr was introduced for about 20 nm into the steel matrix. Tribology tests, of pin-on-disk type, showed that friction coefficient of treated samples was reduced by about 50% and a change in wear mechanism, from adhesive to abrasive mode, occurred.

  17. Improvements of Nickel Deposit Characteristics by Pulse Plating

    DEFF Research Database (Denmark)

    Tang, Peter Torben; Leisner, Peter; Møller, Per

    1993-01-01

    Investigation of the properties of electroplated nickel, using both pulse plating and conventional di-rect current (DC), has lead to several interesting improvements of deposit characteristics. Investigated properties include; internal stress, tensile strength, yield stress, elongation, hardness......, throwing power, current efficiency and corrosion resistance (porosity). Experiments have been made with Watts nickel baths, sulphamate baths and a modified Watts bath called W3....

  18. Create Your Plate

    Medline Plus

    Full Text Available ... Plate It's simple and effective for both managing diabetes and losing weight. Creating your plate lets you still choose the ... Help Enroll in the Living WIth Type 2 Diabetes Program Food & Fitness Food Recipes Planning Meals What Can I Eat Weight Loss Fitness In My Community Calendar of Events ...

  19. mill grinding plates

    African Journals Online (AJOL)

    User

    ABSTRACT. Maize was milled either 'wet' or ''dry'' using locally-manufactured milling plates. Samples of milled maize were taken and analyzed for elemental iron (Fe). Results show that iron particles from milling plates contaminates the milled maize and that the level of contamination increases with the quantity of milled ...

  20. Create Your Plate

    Medline Plus

    Full Text Available ... In Memory In Honor Become a Member En Español Type 1 Type 2 About Us Online Community ... Page Text Size: A A A Listen En Español Create Your Plate Create Your Plate is a ...

  1. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning What Can I Eat? ... Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday ... Foods donate en -- Limited Time MATCH Offer - limited- ...

  2. Create Your Plate

    Medline Plus

    Full Text Available ... Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning ... Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets ...

  3. Effect of heat treatment on wear resistance of a grinding plate ...

    African Journals Online (AJOL)

    The effects of heat treatment on the hardness and by extension the wear resistance of locally produced grinding plate of known composition were investigated. Specimens were prepared from the grinding plate and were heat treated at 840°C, 860°C and 880°C and quenched at different rate. Some of the specimens were ...

  4. Revisiting the definition of local hardness and hardness kernel.

    Science.gov (United States)

    Polanco-Ramírez, Carlos A; Franco-Pérez, Marco; Carmona-Espíndola, Javier; Gázquez, José L; Ayers, Paul W

    2017-05-17

    An analysis of the hardness kernel and local hardness is performed to propose new definitions for these quantities that follow a similar pattern to the one that characterizes the quantities associated with softness, that is, we have derived new definitions for which the integral of the hardness kernel over the whole space of one of the variables leads to local hardness, and the integral of local hardness over the whole space leads to global hardness. A basic aspect of the present approach is that global hardness keeps its identity as the second derivative of energy with respect to the number of electrons. Local hardness thus obtained depends on the first and second derivatives of energy and electron density with respect to the number of electrons. When these derivatives are approximated by a smooth quadratic interpolation of energy, the expression for local hardness reduces to the one intuitively proposed by Meneses, Tiznado, Contreras and Fuentealba. However, when one combines the first directional derivatives with smooth second derivatives one finds additional terms that allow one to differentiate local hardness for electrophilic attack from the one for nucleophilic attack. Numerical results related to electrophilic attacks on substituted pyridines, substituted benzenes and substituted ethenes are presented to show the overall performance of the new definition.

  5. 77 FR 6627 - National Emission Standards for Hazardous Air Pollutant Emissions: Hard and Decorative Chromium...

    Science.gov (United States)

    2012-02-08

    ...: emission elimination devices, high efficiency particulate air (HEPA) filters, wetting agent fume... mist eliminators (MPMEs), high efficiency scrubbers, or HEPA filters. Some facilities use add-on... scrubber) or a combination of add-on controls (such as a CMP plus a HEPA filter or an MPME plus a HEPA...

  6. 75 FR 65067 - National Emission Standards for Hazardous Air Pollutant Emissions: Hard and Decorative Chromium...

    Science.gov (United States)

    2010-10-21

    .... All documents in the docket are listed in the http://www.regulations.gov index. Although listed in the index, some information is not publicly available, e.g., CBI or other information whose disclosure is... .... Randy McDonald, (919) 541-5402, mcdonald[email protected] . Marine Vessel Loading Operations........ Maria...

  7. Citric-acid preacidification enhanced electrokinetic remediation for removal of chromium from chromium-residue-contaminated soil.

    Science.gov (United States)

    Meng, Fansheng; Xue, Hao; Wang, Yeyao; Zheng, Binghui; Wang, Juling

    2018-02-01

    Electrokinetic experiments were conducted on chromium-residue-contaminated soils collected from a chemical plant in China. Acidification-electrokinetic remediation technology was proposed in order to solve the problem of removing inefficient with ordinary electrokinetic. The results showed that electrokinetic remediation removal efficiency of chromium from chromium-contaminated soil was significantly enhanced with acidizing pretreatment. The total chromium [Cr(T)] and hexavalent chromium [Cr(VI)] removal rate of the group acidized by citric acid (0.9 mol/L) for 5 days was increased from 6.23% and 19.01% in the acid-free experiments to 26.97% and 77.66% in the acidification-treated experiments, respectively. In addition, part of chromium with the state of carbonate-combined will be converted into water-soluble state through acidification to improve the removal efficiency. Within the appropriate concentration range, the higher concentration of acid was, the more chromium was released. So the removal efficiency of chromium depended on the acid concentration. The citric acid is also a kind of complexing agent, which produced complexation with Cr that was released by the electrokinetic treatment and then enhanced the removal efficiency. The major speciation of chromium that was removed from soils by acidification-electrokinetics remediation was acid-soluble speciation, revivification speciation and oxidation speciation, which reduced biological availability of chromium.

  8. Femtosecond laser surface structuring and oxidation of chromium thin coatings: Black chromium

    Energy Technology Data Exchange (ETDEWEB)

    Kotsedi, L., E-mail: Kotsedi@tlabs.ac.za [UNESCO-UNISA Africa Chair in Nanosciences-Nanotechnology, College of Graduate Studies, University of South Africa, Muckleneuk Ridge, P.O. Box 392, Pretoria (South Africa); Nanosciences African Network (NANOAFNET), iThemba LABS-National Research Foundation, 1 Old Faure Road, Somerset West 7129, P.O. Box 722, Somerset West, Western Cape (South Africa); Nuru, Z.Y. [UNESCO-UNISA Africa Chair in Nanosciences-Nanotechnology, College of Graduate Studies, University of South Africa, Muckleneuk Ridge, P.O. Box 392, Pretoria (South Africa); Nanosciences African Network (NANOAFNET), iThemba LABS-National Research Foundation, 1 Old Faure Road, Somerset West 7129, P.O. Box 722, Somerset West, Western Cape (South Africa); Mthunzi, P. [National Laser Centre, Council for Scientific and Industrial Research, 0001 Pretoria (South Africa); Muller, T.F.G. [University of the Western Cape, Physics Department, Bellville, 7535 Cape Town (South Africa); Eaton, S.M. [Physics Department, Politecnico di Milano, Piazza Leonardo Da Vinci, 32, 20133 Milano (Italy); Julies, B. [University of the Western Cape, Physics Department, Bellville, 7535 Cape Town (South Africa); Manikandan, E. [UNESCO-UNISA Africa Chair in Nanosciences-Nanotechnology, College of Graduate Studies, University of South Africa, Muckleneuk Ridge, P.O. Box 392, Pretoria (South Africa); Nanosciences African Network (NANOAFNET), iThemba LABS-National Research Foundation, 1 Old Faure Road, Somerset West 7129, P.O. Box 722, Somerset West, Western Cape (South Africa); Ramponi, R. [Physics Department, Politecnico di Milano, Piazza Leonardo Da Vinci, 32, 20133 Milano (Italy); Maaza, M. [UNESCO-UNISA Africa Chair in Nanosciences-Nanotechnology, College of Graduate Studies, University of South Africa, Muckleneuk Ridge, P.O. Box 392, Pretoria (South Africa); Nanosciences African Network (NANOAFNET), iThemba LABS-National Research Foundation, 1 Old Faure Road, Somerset West 7129, P.O. Box 722, Somerset West, Western Cape (South Africa)

    2014-12-01

    Highlights: • Oxidation of the chromium thin film to chromium oxide by femtosecond laser with a fundamental wavelength of 1064 nm. • Solar absorber from chromium oxide that low percentage reflectance. • Femtosecond laser oxidation, with a de-focused laser. • Chromium oxide formation by femtosecond laser in normal ambient. - Abstract: In view of their potential applications as selective solar absorbers, chromium coatings on float glass substrates were nano/micro structured by femtosecond laser in air. Raman and X-rays diffraction investigations confirmed the formation of an ultra-porous α-Cr{sub 2}O{sub 3} layer at the surface; higher is the input laser power, enhanced is the crystallinity of the α-Cr{sub 2}O{sub 3} layer. The α-Cr{sub 2}O{sub 3} layer with the Cr underneath it in addition to the photo-induced porosity acted as a classical ceramic–metal nano-composite making the reflectance to decrease significantly within the spectral range of 190–1100 nm. The average reflectance decreased from 70 to 2%.

  9. Chromium and exercise training: effect on obese women.

    Science.gov (United States)

    Grant, K E; Chandler, R M; Castle, A L; Ivy, J L

    1997-08-01

    Chromium supplementation may affect various risk factors for coronary artery disease (CAD) and non-insulin-dependent diabetes mellitus (NIDDM), including body weight and composition, basal plasma hormone and substrate levels, and response to an oral glucose load. This study examined the effects of chromium supplementation (400 micrograms.d-1), with or without exercise training, on these risk factors in young, obese women. Chromium picolinate supplementation resulted in significant weight gain in this population, while exercise training combined with chromium nicotinate supplementation resulted in significant weight loss and lowered the insulin response to an oral glucose load. We conclude that high levels of chromium picolinate supplementation are contraindicated for weight loss in young, obese women. Moreover, our results suggest that exercise training combined with chromium nicotinate supplementation may be more beneficial than exercise training alone for modification of certain CAD and NIDDM risk factors.

  10. Transformation behavior in low carbon 13% chromium-3% copper stainless steel; Tei C-13%Cr-3%Cu ko no hentai kyodo

    Energy Technology Data Exchange (ETDEWEB)

    Hara, T.; Uemori, R.; Miyasaka, A. [Nippon Steel Corp., Tokyo (Japan)

    2000-10-01

    Martensitic transformation and {gamma} {yields} {alpha} transformation behavior were investigated in low carbon 13% chromium stainless steels containing 2% nickel or 3% copper. The main conclusions are as follows: (1) Hardness of 2% nickel added low carbon 13% chromium steel was independent of cooling rate after hot working at large reduction. Structure of the steel was martensitic even after being subjected to such large reduction of 75%. This result suggests that ferritic transformation was hard to occur under an usual cooling rate because austenite phase was sufficiently stablized by the addition of chromium and nickel. (2) Austenite to ferrite transformation occurred only for the low carbon 13% chromium 3% copper steel without nickel even at the small cooling rate, such as 0.01K/s. This result was mainly attributed to the unstabilization of austenite phase which caused by the precipitation of {epsilon}-Cu. Furthermore, austenite of the steel becomes easy to transform to ferrite due to heavy hot working. This phenomenon was seemed to be caused by the increase in the area of austenite grain boundary owing to recrystallization. Thus, it was considered that the nucleation of {epsilon}-Cu at the grain boundaries promoted ferrite formation. (author)

  11. CHROMIUM(II) AMIDES - SYNTHESIS AND STRUCTURES

    NARCIS (Netherlands)

    EDEMA, JJH; GAMBAROTTA, S; MEETSMA, A; SPEK, AL; SMEETS, WJJ; CHIANG, MY

    1993-01-01

    A novel class of mono- and di-meric chromium(II) amides has been prepared and characterized. Reaction of [CrCl2(thf)2] (thf = tetrahydrofuran) with 2 equivalents of M(NR2) (R = C6H11, Pr(i), Ph, or phenothiazinyl; M = Li or Na) allowed the formation of the homoleptic amides [{Cr(mu-NR2)(NR2)}2] (R =

  12. Chromium Uptake Efficiency of Spinacea olaracea from ...

    African Journals Online (AJOL)

    MICHAEL

    Health 36:197-199. Singh, A.K. 2001. Effect of trivalent and hexavalent chromium on Spinach (Spinacea oleracea). Env. Eco. 19 (4): 807-810. Verma, V.K., Gupta, R.K. and Rai, J.P.N. 2005. Biosorption of Pb and Zn from pulp and paper industry effluent by water hyacinth (Eichornia crassipes). J. Sci. Ind. Res. 64: 778-781.

  13. Dimensionally Controlled Lithiation of Chromium Oxide

    Energy Technology Data Exchange (ETDEWEB)

    Fister, Tim T. [Argonne National Lab. (ANL), Argonne, IL (United States); Hu, Xianyi [Northwestern Univ., Evanston, IL (United States); Esbenshade, Jennifer [Univ. of Illinois, Urbana-Champaign, IL (United States); Chen, Xiao [Northwestern Univ., Evanston, IL (United States); Wu, Jinsong [Northwestern Univ., Evanston, IL (United States); Dravid, Vinayak [Northwestern Univ., Evanston, IL (United States); Bedzyk, Michael [Northwestern Univ., Evanston, IL (United States); Long, Brandon [Argonne National Lab. (ANL), Argonne, IL (United States); Gewirth, Andrew A. [Univ. of Illinois, Urbana-Champaign, IL (United States); Shi, Bing [Argonne National Lab. (ANL), Argonne, IL (United States); Schlepütz, Christian M. [Argonne National Lab. (ANL), Argonne, IL (United States); Fenter, Paul [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-01-12

    Oxide conversion reactions are an alternative approach for high capacity lithium ion batteries but are known to suffer from structural irreversibility associated with the phase separation and reconstitution of reduced metal species and Li2O. In particular, the morphology of the reduced metal species is thought to play a critical role in the electrochemical properties of a conversion material. Here we use a model electrode with alternating layers of chromium and chromium oxide to better understand and control these phase changes in real-time and at molecular length scales. Despite lacking crystallinity at the atomic scale, this superstructure is observed (with X-ray reflectivity, XR) to lithiate and delithiate in a purely one-dimensional manner, preserving the layered structure. The XR data show that the metal layers act as nucleation sites for the reduction of chromium in the conversion reaction. Irreversibility during delithiation is due to the formation of a ternary phase, LiCrO2, which can be further delithiated at higher potentials. The results reveal that the combination of confining lithiation to nanoscale sheets of Li2O and the availability of reaction sites in the metal layers in the layered structure is a strategy for improving the reversibility and mass transport properties that can be used in a wide range of conversion materials.

  14. Pattern of tongue pressure on hard palate during swallowing.

    Science.gov (United States)

    Ono, Takahiro; Hori, Kazuhiro; Nokubi, Takashi

    2004-01-01

    Contact of the tongue against the hard palate plays an important role in swallowing. This study aimed to clarify the pattern of contact between the tongue and hard palate by analyzing tongue pressure produced in swallowing 15 ml of water by healthy subjects wearing an experimental palatal plate with seven pressure sensors. Tongue pressure was generated initially by close contact with the anteriomedian part of the hard palate, then with the circumferential part, and finally softly with the posteriomedian part. Tongue pressure reached a peak quickly, then decreased gradually before disappearing almost simultaneously at each measured part of the hard palate. Magnitude and duration were significantly larger in the anteriomedian part compared to the other six parts measured, and was significantly smaller in the posteriomedian part. No laterality was found in tongue pressure produced at the circumferential parts of the hard palate. Our findings indicate that the order of tongue contact against each part of the hard palate as well as duration and magnitude of tongue pressure are coordinated precisely during swallowing. These findings could aid assessment of the tongue movement of dysphagic patients during rehabilitation.

  15. Robust Ferromagnetism of Chromium Nanoparticles Formed in Superfluid Helium.

    Science.gov (United States)

    Yang, Shengfu; Feng, Cheng; Spence, Daniel; Al Hindawi, Aula M A A; Latimer, Elspeth; Ellis, Andrew M; Binns, Chris; Peddis, Davide; Dhesi, Sarnjeet S; Zhang, Liying; Zhang, Yafei; Trohidou, Kalliopi N; Vasilakaki, Marianna; Ntallis, Nikolaos; MacLaren, Ian; de Groot, Frank M F

    2017-01-01

    Chromium nanoparticles are formed using superfluid helium droplets as the nanoreactors, which are strongly ferromagnetic. The transition from antiferromagentism to ferromagnetism is attributed to atomic-scale disorder in chromium nanoparticles, leading to abundant unbalanced surface spins. Theoretical modeling confirms a frustrated aggregation process in superfluid helium due to the antiferromagnetic nature of chromium. © 2016 The Authors. Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Pixelated neutron image plates

    Science.gov (United States)

    Schlapp, M.; Conrad, H.; von Seggern, H.

    2004-09-01

    Neutron image plates (NIPs) have found widespread application as neutron detectors for single-crystal and powder diffraction, small-angle scattering and tomography. After neutron exposure, the image plate can be read out by scanning with a laser. Commercially available NIPs consist of a powder mixture of BaFBr : Eu2+ and Gd2O3 dispersed in a polymer matrix and supported by a flexible polymer sheet. Since BaFBr : Eu2+ is an excellent x-ray storage phosphor, these NIPs are particularly sensitive to ggr-radiation, which is always present as a background radiation in neutron experiments. In this work we present results on NIPs consisting of KCl : Eu2+ and LiF that were fabricated into ceramic image plates in which the alkali halides act as a self-supporting matrix without the necessity for using a polymeric binder. An advantage of this type of NIP is the significantly reduced ggr-sensitivity. However, the much lower neutron absorption cross section of LiF compared with Gd2O3 demands a thicker image plate for obtaining comparable neutron absorption. The greater thickness of the NIP inevitably leads to a loss in spatial resolution of the image plate. However, this reduction in resolution can be restricted by a novel image plate concept in which a ceramic structure with square cells (referred to as a 'honeycomb') is embedded in the NIP, resulting in a pixelated image plate. In such a NIP the read-out light is confined to the particular illuminated pixel, decoupling the spatial resolution from the optical properties of the image plate material and morphology. In this work, a comparison of experimentally determined and simulated spatial resolutions of pixelated and unstructured image plates for a fixed read-out laser intensity is presented, as well as simulations of the properties of these NIPs at higher laser powers.

  17. Hard photoproduction at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Klasen, M. [Laboratoire de Physique Subatomique et de Cosmologie, Universite Joseph Fourier / CNRS-IN2P3, 53 Avenue des Martyrs, F-38026 Grenoble (France)

    2007-07-01

    In view of possible photoproduction studies in ultra-peripheral heavy-ion collisions at the LHC, we briefly review the present theoretical understanding of photons and hard photoproduction processes at HERA, discussing the production of jets, light and heavy hadrons, quarkonia, and prompt photons. We address in particular the extraction of the strong coupling constant from photon structure function and inclusive jet measurements, the infrared safety and computing time of jet definitions, the sensitivity of di-jet cross sections on the parton densities in the photon, factorization breaking in diffractive di-jet production, the treatment of the heavy-quark mass in charm production, the relevance of the color-octet mechanism for quarkonium production, and isolation criteria for prompt photons. (author)

  18. Spectroscopic studies on the interaction of chromium (VI) and chromium (III) with keyhole limpet hemocyanin.

    Science.gov (United States)

    Fan, Yulan; Zeng, Guidi; Liu, Jingyi; Chen, Huifang; Xue, Jun; Wu, Yongquan; Li, Xun

    2017-03-01

    The interactions of keyhole limpet hemocyanin (KLH) with chromium nitrate, potassium dichromate, and chromate were investigated using fluorescence, UV-vis absorption and circular dichroism (CD) spectroscopy under simulated physiological conditions. The experimental results showed that the different forms of chromium could quench the intrinsic fluorescence of KLH following a static quenching mechanism rather than by dynamic collision, which indicated that a Cr-KLH complex was formed. The Stern-Volmer quenching constants for the interaction indicated that the binding reaction of KLH with Cr(VI) was stronger the binding of KLH with Cr(III). The thermodynamic values for binding of Cr(VI) to KLH are ΔH > 0 and ΔS > 0. By contrast, the values for the interaction of Cr(III) with KLH are ΔH chromium. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  19. Anisotropic elastic plates

    CERN Document Server

    Hwu, Chyanbin

    2010-01-01

    As structural elements, anisotropic elastic plates find wide applications in modern technology. The plates here are considered to be subjected to not only in plane load but also transverse load. In other words, both plane and plate bending problems as well as the stretching-bending coupling problems are all explained in this book. In addition to the introduction of the theory of anisotropic elasticity, several important subjects have are discussed in this book such as interfaces, cracks, holes, inclusions, contact problems, piezoelectric materials, thermoelastic problems and boundary element a

  20. Plating in Top Agar

    OpenAIRE

    sprotocols

    2014-01-01

    1. Warm plates to room temperature before use. Cold plates causes the top agar to solidify irregularly. DO not warm plates to 37° as the top agar will take forever to solidify. - Prepare top agar as the appropriate liquid medium with 0.7% agar. Keeping 100 mL bottles is convenient. For phages, use λ top agar, which is less rich and yields bigger plaques. - Melt top agar in the microwave completely. Allow the agar to boil after liquification; incompletely melted agar looks liquid, but is...

  1. Evaluation Of Cobalt and Chromium Levels Following Implantation of Cobalt Chromium Coronary Stents: A Pilot Study.

    Science.gov (United States)

    Di Santo, Pietro; Motazedian, Pouya; Jung, Richard G; Simard, Trevor; Ramirez, F Daniel; Chong, Aun-Yeong; Glover, Christopher; Hibbert, Benjamin; Dwivedi, Girish

    2017-12-14

    Large increases in myocardial trace elements may adversely affect metabolism and become detrimental to cardiac function. Percutaneous coronary intervention (PCI) allows for the revascularisation of obstructive coronary artery disease using drug-eluting stents. These stents are comprised of a metallic stent backbone covered in an engineered polymer which delivers a drug over a prescribed period to the vessel wall. Given the potential implications of trace metal accumulation within the myocardium, our goal is to determine if metallic coronary stents are able to cause detectable elevations in serum cobalt and/or chromium levels. This study was a single centre, observational, pilot study with 20 patients who underwent planned PCI with implantation of a cobalt chromium drug eluting stent. Serum blood samples were drawn at baseline prior to PCI, 4hours post-stent deployment and at the time of routine follow-up after PCI. All blood samples were analysed for cobalt and chromium concentrations. The primary outcome of this study was the difference in serum cobalt and chromium levels at routine clinical follow-up. The mean follow up was 64.1±17.3 days. There was no difference in serum cobalt levels when comparing baseline and routine clinical follow up (3.32±2.14nmol/L vs. 3.14±1.00nmol/L, p=0.99) nor in chromium levels (4.24±2.31nmol/L vs. 2.82±1.22 nmol/L, p=0.11). There was also no difference between baseline and 4hours post-PCI serum concentrations. Percutaneous coronary intervention with cobalt chromium coronary stents does not appear to cause an elevation in these trace element serum concentrations. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.

  2. Isolation and characterization of a chromium-resistant bacterium Serratia sp. Cr-10 from a chromate-contaminated site

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Kundi; Li, Fuli [Chinese Academy of Sciences, Qingdao (China). Qingdao Inst. of Bioenergy and Bioprocess Technology

    2011-05-15

    A novel bacterium, Cr-10, was isolated from a chromium-contaminated site and capable of removing toxic chromium species from solution by reducing hexavalent chromium to an insoluble precipitate. Sequence analysis of 16S rRNA gene of strain Cr-10 showed that it was most closely related to Serratia rubidaea JCM 1240{sup T} (97.68%). Physiological and chemotaxonomic data also supported that strain Cr-10 was identified as Serratia sp., a genus which was never specially reported chromate-resistant before. Serratia sp., Cr-10 was tolerant to a concentration of 1,500 mg Cr(VI) L{sup -1}, which was the highest level reported until now. The optimum pH and temperature for reduction of Cr(VI) by Serratia sp. Cr-10 were found to be 7.0 and 37 C, respectively. The Cr(VI) reduction was significantly influenced by additional carbon sources, and among them fructose and lactose offered maximum reduction, with a rate of 0.28 and 0.25 mg Cr(VI) L{sup -1} h{sup -1}, respectively. The cell-free extracts and filtrate of the culture were able to reduce Cr(VI) while concentration of total chromium remained stable in the process, indicating that the enzyme-catalyzed mechanism was applied in Cr(VI) reduction by the isolate. Additionally, it was found that there was hardly any chromium on the cell surface of the strain, further supporting that reduction, rather than bioadsorption, plays a major role in the Cr(VI) removal. (orig.)

  3. Analysing the chromium-chromium multiple bond using multiconfigurational quantum chemistry

    OpenAIRE

    Brynda, Marcin; Gagliardi, Laura; Roos, Björn O.

    2009-01-01

    This Letter discusses the nature of the chemical bond between two chromium atoms in different di-chromium complexes with the metal atoms in different oxidation states. Starting with the Cr diatom, with its formally sextuple bond and oxidation number zero, we proceed to analyse the bonding in some Cr(I)–Cr(I) XCrCrX complexes with X varying from F, to Phenyl, and Aryl. The bond distance in these complexes varies over a large range: 1.65–1.83 Å and we suggest explanations for these variations. ...

  4. Janka hardness using nonstandard specimens

    Science.gov (United States)

    David W. Green; Marshall Begel; William Nelson

    2006-01-01

    Janka hardness determined on 1.5- by 3.5-in. specimens (2×4s) was found to be equivalent to that determined using the 2- by 2-in. specimen specified in ASTM D 143. Data are presented on the relationship between Janka hardness and the strength of clear wood. Analysis of historical data determined using standard specimens indicated no difference between side hardness...

  5. Industrial Implementation of Environmentally Friendly Nanometal Electroplating Process for Chromium and Copper Beryllium Replacement using Low Cost Pulse Current Power Supplies

    Science.gov (United States)

    2014-09-10

    nanostructured cobalt - alloy bushing, and (b) a micrograph of the hardness indents from measurements made across the cross-section. .... 68 Figure 4-21...Vickers Microhardnes measurements as a function of the distance across the cross- section of the large scale electroformed Nanostructured cobalt - alloy ...Nanometal Electroplating Process for Chromium and Copper-Beryllium Replacement using Low Cost Pulse Current Power Supplies.” Nanostructured alloys are

  6. 2TB hard disk drive

    CERN Multimedia

    This particular object was used up until 2012 in the Data Centre. It slots into one of the Disk Server trays. Hard disks were invented in the 1950s. They started as large disks up to 20 inches in diameter holding just a few megabytes (link is external). They were originally called "fixed disks" or "Winchesters" (a code name used for a popular IBM product). They later became known as "hard disks" to distinguish them from "floppy disks (link is external)." Hard disks have a hard platter that holds the magnetic medium, as opposed to the flexible plastic film found in tapes and floppies.

  7. Create Your Plate

    Medline Plus

    Full Text Available ... Health Care Professionals Law Enforcement Driver's License For Lawyers Food & Fitness Home Food MyFoodAdvisor Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten ...

  8. Create Your Plate

    Medline Plus

    Full Text Available ... Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy 8 Tips for ... Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart- ...

  9. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning What Can I Eat? Making Healthy Food Choices Diabetes Superfoods Non-starchy Vegetables Grains and Starchy Vegetables ...

  10. Create Your Plate

    Medline Plus

    Full Text Available ... Diabetes Resources for School Projects How to Reference Our Site Diabetes Basics Myths Common Terms Research Resources ... to manage portion control wherever you are. Now, our best-selling, sectioned to-go plate with easy- ...

  11. Create Your Plate

    Medline Plus

    Full Text Available ... breast cancer and AIDS combined. Your gift today will help us get closer to curing diabetes and ... on one side, cut it again so you will have three sections on your plate. Fill the ...

  12. Tectonic Plate Movement.

    Science.gov (United States)

    Landalf, Helen

    1998-01-01

    Presents an activity that employs movement to enable students to understand concepts related to plate tectonics. Argues that movement brings topics to life in a concrete way and helps children retain knowledge. (DDR)

  13. Create Your Plate

    Medline Plus

    Full Text Available ... one side, cut it again so you will have three sections on your plate. Fill the largest ... home, the office, or somewhere in between, you have an easy portion control solution that works. Last ...

  14. Create Your Plate

    Medline Plus

    Full Text Available ... and Pacific Islanders American Indian/Alaska Native Programs Older Adults Family Link Diabetes EXPO Upcoming Diabetes EXPOs ... Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets ...

  15. Create Your Plate

    Medline Plus

    Full Text Available ... losing weight. Creating your plate lets you still choose the foods you want, but changes the portion ... dairy or both as your meal plan allows. Choose healthy fats in small amounts. For cooking, use ...

  16. Create Your Plate

    Medline Plus

    Full Text Available ... of Diabetes Research & Practice Home We Are Research Leaders World's Largest Diabetes Meeting Recent Advances Type 1 ... Plate is a simple and effective way to manage your blood glucose levels and lose weight. With ...

  17. Create Your Plate

    Medline Plus

    Full Text Available ... Safely Get And Stay Fit Types of Activity Weight Loss Assess Your Lifestyle Getting Started Food Choices In ... way to manage your blood glucose levels and lose weight. With this method, you fill your plate with ...

  18. Create Your Plate

    Medline Plus

    Full Text Available ... manage portion control wherever you are. Now, our best-selling, sectioned to-go plate with easy-sealing ... Research Leaders We Support Your Doctor Student Resources Patient Access to Research Research Resources Practice Resources Ways ...

  19. Radiation Hard and High Light Yield Scintillator Search for CMS Phase II Upgrade

    CERN Document Server

    Tiras, Emrah

    2015-01-01

    The CMS detector at the LHC requires a major upgrade to cope with the higher instantaneous luminosity and the elevated radiation levels. The active media of the forward backing hadron calorimeters is projected to be radiation-hard, high light yield scintillation materials or similar alternatives. In this context, we have studied various radiation-hard scintillating materials such as Polyethylene Terephthalate (PET), Polyethylene Naphthalate (PEN), High Efficiency Mirror (HEM) and quartz plates with various coatings. The quartz plates are pure Cerenkov radiators and their radiation hardness has been confirmed. In order to increase the light output, we considered organic and inorganic coating materials such as p-Terphenyl (pTp), Anthracene and Gallium-doped Zinc Oxide (ZnO Ga) that are applied as thin layers on the surface of the quartz plates. Here, we present the results of the related test beam activities, laboratory measurements and recent developments.

  20. A spectroscopic study for understanding the speciation of Cr on palm shell based adsorbents and their application for the remediation of chrome plating effluents.

    Science.gov (United States)

    Kushwaha, Shilpi; Sreedhar, B; Sudhakar, Padmaja P

    2012-07-01

    Palm shell based adsorbents prepared under five different thermochemical conditions have been shown to be quite effective for removal of chromium (III and VI) from aqueous solutions. X-ray photoelectron spectroscopy (XPS) and Fourier Transform Infrared Spectroscopy (FT-IR) have been used to determine information about the speciation and binding of chromium on the adsorbents under study. X-ray photoelectron spectroscopy (XPS) studies indicate that oxidation of lignin moieties takes place concurrently to Cr(VI) reduction and leads to the formation of hydroxyl and carboxyl functions. The maximum adsorption capacity for hexavalent chromium was found to be about 313 mg/g in an acidic medium using PAPSP. This is comparable to other natural substrates and ordinary adsorbents. The efficacy of the adsorbents under study to remove chromium from plating waste water has been demonstrated. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Determination of optimum heat treatment conditions for hardness criterion of multicomponent steel based on fuzzy mathematical simulation

    Directory of Open Access Journals (Sweden)

    Александр Алексеевич Радченко

    2016-06-01

    Full Text Available The mathematical simulation of high-strength cast steel grade alloyed with manganese, nickel, chromium and molybdenum, and heat treatment conditions on the steel hardness are done. The model is developed on the basis of orthogonal experimental design, in which the input variables are considered as fuzzy numbers. The optimal heat treatment conditions for steels 25ГНХМЛ, 35ГНХМЛ, 40ГНХМЛ are determined

  2. Vibration and Buckling of Web Plate of the Plate Girder

    OpenAIRE

    高橋, 和雄; 呉, 明強; 中澤, 聡志; 筑紫, 宏之

    1998-01-01

    The vibration and buckling of the web of the plate girder are studied in this paper. The small deflection theory of the thin plate is used. The finite strip method is employed to solve vibration and buckling of the plate girder. Natural frequenies of buckling properties are shown for various plate girder bridges.

  3. A study on the mechanical characteristics of the EBM-printed Ti-6Al-4V LCP plates in vitro.

    Science.gov (United States)

    Liu, Peng-Cheng; Yang, Yun-Ji; Liu, Run; Shu, He-Xi; Gong, Jin-Peng; Yang, Yong; Sun, Qi; Wu, Xing; Cai, Ming

    2014-11-05

    The electron beam melting (EBM) Ti-6Al-4V material technology has been developed over a short time period. It was introduced through a research to develop Ti-6Al-4V implants for patients, but EBM printed locking compression plates have not been used for clinical implants. The main purpose of this study is to find whether the EBM Ti-6Al-4V plate suit for clinical implants. First, we scanned an AO-locking compression plate (LCP) and printed LCP samples using EBM. Next, we evaluated the EBM plate surface roughness through optical microscopy as well as the LCP and EBM plates' mechanical characteristics using the ASTM standard, which is commonly used to test the mechanical properties of bone plates subject to bending. Each sample was examined using a single-cycle four-point bending test and hardness testing to acquire data on bending stiffness, bending strength, bending structural stiffness, and hardness. The results show significant differences in bending stiffness, bending strength, bending structural stiffness, and hardness between the samples using EBM and the original LCP plates. The EBM-printed samples' surface roughness was 0.49 ± 0.02 μm. The mean hardness of the LCP sample was 266.67 HV10 ± 5.8, and the EBM-printed sample mean hardness was 341.1 HV10 ± 1.93. The EBM samples' bending stiffness was 87.67%, which is greater than using the LCP plates'; and the bending strength was 190.7% greater, the bending structural stiffness was 73.2% greater, and the hardness was 27.9% greater. The results show that the EBM plates' general mechanical strength was significantly greater than the LCP plates. An EBM plate is advantageous for clinical implants because it can be customized with great potential for improvement.

  4. Hard coal; Steinkohle

    Energy Technology Data Exchange (ETDEWEB)

    Loo, Kai van de; Sitte, Andreas-Peter [Gesamtverband Steinkohle e.V. (GVSt), Herne (Germany)

    2015-07-01

    International the coal market in 2014 was the first time in a long time in a period of stagnation. In Germany, the coal consumption decreased even significantly, mainly due to the decrease in power generation. Here the national energy transition has now been noticable affected negative for coal use. The political guidances can expect a further significant downward movement for the future. In the present phase-out process of the German hard coal industry with still three active mines there was in 2014 no decommissioning. But the next is at the end of 2015, and the plans for the time after mining have been continued. [German] International war der Markt fuer Steinkohle 2014 erstmals seit langem wieder von einer Stagnation gekennzeichnet. In Deutschland ging der Steinkohlenverbrauch sogar deutlich zurueck, vor allem wegen des Rueckgangs in der Stromerzeugung. Hier hat sich die nationale Energiewende nun spuerbar und fuer die Steinkohlennutzung negativ ausgewirkt. Die politischen Weichenstellungen lassen fuer die Zukunft eine weitere erhebliche Abwaertsbewegung erwarten. Bei dem im Auslaufprozess befindlichen deutschen Steinkohlenbergbau mit noch drei aktiven Bergwerken gab es 2014 keine Stilllegung. Doch die naechste steht zum Jahresende 2015 an, und die Planungen fuer die Zeit nach dem Bergbau sind fortgefuehrt worden.

  5. Bioreduction of chromium (VI) to chromium (III) by a novel yeast ...

    African Journals Online (AJOL)

    Introduction of heavy metal compounds like chromium, lead, arsenic and mercury into the environment generally induces morphological and physiological changes in the microbial communities hence exerting a selective pressure on the microorganisms. Generally, sites which are contaminated with heavy metals are the ...

  6. Biological groundwater treatment for hexavalent chromium removal at low chromium concentrations under anoxic conditions.

    Science.gov (United States)

    Panousi, E; Mamais, D; Noutsopoulos, C; Mpertoli, K; Kantzavelou, C; Nyktari, E; Kavallari, I; Nasioka, M; Kaldis, A

    2017-10-31

    The objective of this work is to evaluate biological groundwater treatment systems that will achieve hexavalent chromium removal from groundwater at hexavalent chromium (Cr(VI)) groundwater concentrations in the 0-200 μg/L range under anoxic conditions. The effect of type of organic substrate added as feed to the groundwater treatment system (milk, sugar and cheese whey), the effect of different concentrations of chemical oxygen demand added in the feed (100, 150 and 200 mg/L) and the effect of different hydraulic residence time (1.7, 0.9 and 0.7 d) on process performance were evaluated through the operation of a series of sequential batch reactors under anoxic conditions. Biomass receiving Cr(VI) contaminated groundwater with a low nitrates content exhibited similar Cr(VI) removal efficiency under reductive conditions, with biomass receiving Cr(VI) contaminated groundwater with a high nitrates content. The concentration of organic substrate was crucial for the microbial reduction of Cr(VI). The different hydraulic residence time of the reactors and the different types of organic substrates added did not affect the efficiency of hexavalent chromium removal which was complete. This study demonstrates that biological systems operating under reductive conditions can efficiently treat groundwater containing low or high nitrates concentration and can provide complete hexavalent chromium removal at initial Cr(VI) concentrations of 200 μg/L.

  7. Safety, absorption, and antioxidant effects of chromium histidine

    Science.gov (United States)

    Supplemental chromium has been shown to be involved in the alleviation of the metabolic syndrome, glucose intolerance, polycystic ovary syndrome, depression, excess body fat, and gestational, steroid-induced, and type 2 diabetes. Chromium amino acid complexes that contained histidine displayed cons...

  8. Evaluation of Cooking Quality of Chromium Fortified - Parboiled Rice

    Science.gov (United States)

    Yulianto, W. A.; Suryani, C. L.; Ulfah, S.

    2017-04-01

    Parboiled rice was developed to produce rice that has low glycemic index, especially for diabetics. Yet, parboiled rice is not enough because diabetics also lack of chromium. The purpose of this experiment is to investigate the influence of paddy soaking time and chromium fortification on cooking quality of chromium fortified - parboiled rice (Cr -PR). The paddy was soaked for 2.5, 3.0, and 3.5 hours with chromium fortification at 0, 1.08, 3.42, 5.40 and 7.47 mg/L. The paddy soaked in different time and chromium fortification level did not affect the alkali spreading value and cooking time of CR-PR. The elongation of Cr-PR was from 1.39 to 1.48. Water uptake ratio increased due to addition of chromium, but the more addition of chromium (> 1.08 mg/L) the less water uptake ratio increase. The rice solid loss declined and it was influenced by the length of soaking time. The longer the soaking time and the higher the chromium addition, the harder the rice texture generated.

  9. remediation potential of Eichornia sp in conjunction with chromium

    African Journals Online (AJOL)

    study Cr (VI) reduction increased gradually in mobilized state with increased time of contact. Removal of hexavalent chromium by Eichornia sp. was more effective in the presence of chromium resistant bacterial strains. Aquatic plants released minerals helping bacteria to survive and in return, bacteria supported plants.

  10. Effects of chromium uptake on the growth characteristics of ...

    African Journals Online (AJOL)

    The uptake of chromium from fresh water by Eichhornia crassipes was studied under greenhouse conditions where the species was raised in culture solutions containing varying ... Plant growth analysis techniques were applied to assess the effects of chromium on the growth characteristics of the treated E. crassipes plants.

  11. Evaluation of selected wetland plants for removal of chromium from ...

    African Journals Online (AJOL)

    user

    electrolysis system (Vlyssides and Israilides, 1997) and chemical removal ... wetland subsurface flow cells, each with a length of 4.2 m, width of. 0.8 m and .... Technol. Figure 2. A) Cr adsorbed on clay soil; B) Percentage of chromium partitioning in CWs (in g of Cr); C) Chromium removal efficiency of each CW cells. Table 3.

  12. Biosorption of chromium by mangrove-derived Aplanochytrium sp ...

    African Journals Online (AJOL)

    The microbial dried biomass of Thraustochytrids is used as bioadsorbent for the removal of the chromium in aqueous solution. In this investigation, three species of Thraustochydrids namely Aplanochytrium sp., Thraustochytrium sp. and Schizochytrium sp. were tested for the efficiency of chromium accumulation by culturing ...

  13. Biosorption of trivalent chromium on the brown seaweed biomass.

    Science.gov (United States)

    Yun, Y S; Park, D; Park, J M; Volesky, B

    2001-11-01

    Biosorption has attracted attention as a cost-effective means for the treatment of metal-bearing wastewater. However, the mechanism of metal binding is not clearly understood, and consequently, modeling of the biosorption performance is still raising debates. In this study, the biosorption of trivalent chromium was investigated with protonated brown alga Ecklonia biomass as a model system. Titration of the biomass revealed that it contains at least three types of functional groups. The Fourier transform infrared spectrometry showed that the carboxyl group was the chromium-binding site within the pH range (pH 1-5) used in this study, where chromium does not precipitate. The pK value and the number of carboxyl groups were estimated to be 4.6 +/- 0.1 and 2.2 +/- 0.1 mmol/g, respectively. The equilibrium sorption isotherms determined at different solution pH indicated that the uptake of chromium increased significantly with increasing pH. A model for the description of chromium biosorption was developed incorporating the hydrolysis reactions that chromium undergoes in the aquatic phase. The model was able to predict the equilibrium sorption experimental data at different pH values and chromium concentrations. In addition, the speciation of the binding site as a function of the solution pH was predicted using the model in order to visualize the distribution of chromium ionic species on the binding site.

  14. Optical emission from laser-produced chromium and magnesium ...

    Indian Academy of Sciences (India)

    Parametric study of optical emission from two successive laser pulses produced chromium and magnesium plasma is presented. The line emission from chromium and magnesium plasma showed an increase by more than six times for double laser pulse excitation than for single-pulse excitation. An optimum increase in ...

  15. Removal of chromium and lead from drill cuttings using activated ...

    African Journals Online (AJOL)

    Palm kernel shell and Palm kernel husk, two readily available agricultural waste products have been used as low-cost potential adsorbents to remove chromium and lead from drill cuttings. Batch adsorption studies were carried out as a function of parameters such as pH, contact time and carbon dosage. Chromium and ...

  16. induced Oxidation of Chromium(iii) by Peroxodisulphate

    African Journals Online (AJOL)

    2Institute for Inorganic Chemistry, University of Erlangen-Nürnberg, Egerlandstrasse 1, 91058 Erlangen, Germany. Received 1 December 2003; revised 13 August 2004; accepted 1 October 2004. ABSTRACT. Chromium(III) and chromium(VI) compounds play an important role in natural oxidation processes in terrestrial and ...

  17. Predicting chromium (VI) adsorption rate in the treatment of liquid ...

    African Journals Online (AJOL)

    The adsorption rate of chromium (VI) on commercial activated carbon during the treatment of the flocculation effluent of liquid-phase oil-based drill-cuttings has been investigated in terms of contact time and initial chromium (VI) ion concentration. Homogenizing 1 g of the activated carbon with 100 ml of the flocculation ...

  18. Cobalt chromium sublaminar wires for spinal deformity surgery.

    Science.gov (United States)

    Cluck, Michael W; Skaggs, David L

    2006-09-01

    Biomechanical analysis and retrospective chart review. To determine the mechanical properties of cobalt chromium alloy wires and review the clinical application of the wires as sublaminar implants to correct spinal deformity. Sublaminar wires are commonly used as anchors in spinal deformity surgery. In stainless steel instrumentation systems, single strand wires (Luque wires) may be retightened over time to take advantage of stress relaxation while correcting spinal deformity. Because of the mechanical properties of titanium, solid titanium wires are not used as sublaminar wires. Cobalt chromium alloy is a titanium compatible alloy that can be twisted in a similar fashion to stainless steel sublaminar wires. Comparative tensile tests were performed using cobalt chromium alloy wires and Luque stainless steel wires. In addition, 22 consecutive posterior spinal fusions for idiopathic scoliosis were performed using cobalt chromium alloy wires as sublaminar implants. Yield and ultimate tensile loads for the cobalt chromium alloy wires are on average 66% (P cobalt chromium alloy wires were used as sublaminar implants. Mean preoperative lumbar curve was 52 degrees +/- 14 degrees , which corrected to 17 degrees +/- 8 degrees (68% correction, P cobalt chromium alloy wire over steel wire include greater tensile strength and titanium compatibility. Cobalt chromium alloy solid wires may be used as sublaminar implants with titanium spinal instrumentation with excellent clinical results.

  19. Effect of chromium toxicity on germination and early seedling growth ...

    African Journals Online (AJOL)

    This study was conducted to determine and compare the inhibitory effects of chromium on seed germination and early seedling growth of melon (Cucumis melo L.). Chromium applications were controls; 2.5, 5, 10, 25, 50, 75, 100, 200 and 300 mgl-1 Cr in germination stage, and controls; 2.5, 5, 10, 20, 30, 40, 50, 60 and 70 ...

  20. Serum chromium concentrations in type 2 diabetic patients attending ...

    African Journals Online (AJOL)

    A highly refined diet that contains too few micronutrients has been recognized as the dominant factor in the rising incidence of diabetes and other insulin related conditions. Among the missing micronutrients, chromium has the greatest impact on insulin response. The objective of this study was to determine serum chromium ...

  1. Optimization of chromium biosorption in aqueous solution by marine ...

    African Journals Online (AJOL)

    Optimization of a chromium biosorption process was performed by varying three independent variables pH (0.5 to 3.5), initial chromium ion concentration (10 to 30 mg/L), and Yarrowia lipolytica dosage (2 to 4 g/L) using a Doehlert experimental design (DD) involving response surface methodology (RSM). For the maximum ...

  2. Effects of chromium supplementation on growth, nutrient digestibility ...

    African Journals Online (AJOL)

    Effects of chromium supplementation on growth, nutrient digestibility and meat quality of growing pigs. ... South African Journal of Animal Science ... The aim of the study was to evaluate the effects of chromium picolinate (CrPic) on growth performance, nutrient digestibility, and protein and lipid quality of five anatomical parts ...

  3. Bioremediation of chromium in tannery effluent by microbial consortia

    African Journals Online (AJOL)

    Chromium is the most toxic and common among the heavy metal pollutants of industrial effluents. In the present work the chromium remediation ability of Bacillus subtilis, Pseudomonas aeruginosa and Saccharomyces cerevisiae in consortia and in their immobilized forms was studied and their efficiencies were compared.

  4. Chromium genotoxicity: a double-edged sword

    Science.gov (United States)

    Nickens, Kristen P.; Patierno, Steven R.; Ceryak, Susan

    2010-01-01

    Certain forms of hexavalent chromium [Cr(VI)] are known respiratory carcinogens that induce a broad spectrum of DNA damage. Cr(VI)-carcinogenesis may be initiated or promoted through several mechanistic processes including, the intracellular metabolic reduction of Cr(VI) producing chromium species capable of interacting with DNA to yield genotoxic and mutagenic effects, Cr(VI)-induced inflammatory/immunological responses, and alteration of survival signaling pathways. Cr(VI) enters the cell through nonspecific anion channels, and is metabolically reduced by agents including ascorbate, glutathione, and cysteine to Cr(V), Cr(IV), and Cr(III). Cr(III) has a weak membrane permeability capacity and is unable to cross the cell membrane, thereby trapping it within the cell where it can bind to DNA and produce genetic damage leading to genomic instability. Structural genetic lesions produced by the intracellular reduction of Cr(VI) include DNA adducts, DNA strand breaks, DNA-protein crosslinks, oxidized bases, abasic sites, and DNA inter- and intrastrand crosslinks. The damage induced by Cr(VI) can lead to dysfunctional DNA replication and transcription, aberrant cell cycle checkpoints, dysregulated DNA repair mechanisms, microsatelite instability, inflammatory responses, and the disruption of key regulatory gene networks responsible for the balance of cell survival and cell death, which may all play an important role in Cr(VI) carcinogenesis. Several lines of evidence have indicated that neoplastic progression is a result of consecutive genetic/epigenetic changes that provide cellular survival advantages, and ultimately lead to the conversion of normal human cells to malignant cancer cells. This review is based on studies that provide a glimpse into Cr(VI) carcinogenicity via mechanisms including Cr(VI)-induced death-resistance, the involvement of DNA repair mechanisms in survival after chromium exposure, and the activation of survival signaling cascades in response to Cr

  5. Chromium in urothelial carcinoma of the bladder.

    Science.gov (United States)

    Golabek, Tomasz; Socha, Katarzyna; Kudelski, Jacek; Darewicz, Barbara; Markiewicz-Zukowska, Renata; Chlosta, Piotr; Borawska, Maria

    2017-12-23

    Many epidemiological and experimental studies report a strong role of chemical carcinogens in the etiology of bladder cancer. However, the involvement of heavy metals in tumourigenesis of urothelial carcinoma of the bladder has been poorly investigated. Therefore, the aim of this study was to examine the relationship between chromium (Cr) and bladder cancer. Chromium concentration in two 36-sample series of bladder cancer tissue and sera from patients with this neoplasm were matched with those of a control group. The amount of trace elements in every tissue sample was determined using atomic absorption spectrometry. This was correlated with tumour stage. While the median chromium concentration levels reached statistically higher values in the bladder cancer tissue, compared with the non-cancer tissue (99.632ng/g and 33.144ng/g, respectively; p<0.001), the median Cr levels in the sera of the patients with this carcinoma showed no statistical difference when compared to those of the control group (0.511μg/l and 0.710μg/l, respectively; p=0.408). The median levels of Cr in the bladder tissue, depending on the stage of the tumour, compared with the tissue without the neoplasm, observed the same relationship for both non-muscle invasive and muscle-invasive tumours (p<0.001 and p<0.01, respectively). This study shows that patients with urothelial carcinoma of the bladder had higher tissue Cr levels than people without tumour, while no difference was found in the Cr serum levels between the two groups of patients under investigation.

  6. 77 FR 264 - Certain Cut-To-Length Carbon-Quality Steel Plate From India, Indonesia, and the Republic of Korea...

    Science.gov (United States)

    2012-01-04

    ... characteristics that are painted, varnished or coated with plastic or other non-metallic substances are included.... HSLA steels are recognized as steels with micro- alloying levels of elements such as chromium, copper..., plated, or coated with metal, whether or not painted, varnished or coated with plastic or other non...

  7. Magnesite and chromium-magnesite refractories

    Energy Technology Data Exchange (ETDEWEB)

    Campos Loriz, D.

    1981-01-01

    The fifth part of the series, is concerned with a study on magnesite refractories, essential to the basic steelplant and starts with both traditional (natural carbonates and hydroxides) and recently-used (sea-water hydroxide) raw materials. Following a discussion on the fundamental system MgO-CaO-Si/sub 2/ consideration is given, among others, to baked, tarred and chemically-bonded refractories; their properties and use, ending with a brief examination of conventional and direct-bond chromium-magnesite materials.

  8. Bending and stretching of plates

    CERN Document Server

    Mansfield, E H; Hemp, W S

    1964-01-01

    The Bending and Stretching of Plates deals with elastic plate theory, particularly on small- and large-deflexion theory. Small-deflexion theory concerns derivation of basic equations, rectangular plates, plates of various shapes, plates whose boundaries are amenable to conformal transformation, plates with variable rigidity, and approximate methods. Large-deflexion theory includes general equations and some exact solutions, approximate methods in large-deflexion theory, asymptotic large-deflexion theories for very thin plates. Asymptotic theories covers membrane theory, tension field theory, a

  9. Chromium allergy and dermatitis: prevalence and main findings.

    Science.gov (United States)

    Bregnbak, David; Johansen, Jeanne D; Jellesen, Morten S; Zachariae, Claus; Menné, Torkil; Thyssen, Jacob P

    2015-11-01

    The history of chromium as an allergen goes back more than a century, and includes an interventional success with national legislation that led to significant changes in the epidemiology of chromium allergy in construction workers. The 2015 EU Leather Regulation once again put a focus on chromium allergy, emphasizing that the investigation of chromium allergy is still far from complete. Our review article on chromium focuses on the allergen's chemical properties, its potential exposure sources, and the allergen's interaction with the skin, and also provides an overview of the regulations, and analyses the epidemiological pattern between nations and across continents. We provide an update on the allergen from a dermatological point of view, and conclude that much still remains to be discovered about the allergen, and that continued surveillance of exposure sources and prevalence rates is necessary. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. New Evidence against Chromium as an Essential Trace Element.

    Science.gov (United States)

    Vincent, John B

    2017-12-01

    Nearly 60 y ago, chromium, as the trivalent ion, was proposed to be an essential element, but the results of new studies indicate that chromium currently can only be considered pharmacologically active and not an essential element. Regardless, articles still continue to appear in the literature claiming chromium is an essential element. Chromium has been marketed as an agent to reduce body mass and develop muscle; however, such marketing claims are no longer allowed in the United States because these claims, similar to claims of essential status, are not supported by experiments. Trivalent chromium has also been proposed as a therapeutic agent to increase insulin sensitivity and affect lipid metabolism. Although effective in certain rodent models, beneficial effects in humans have not been unequivocally established. Molecular mechanisms have been proposed for the beneficial effects but have not been definitively shown to occur in animals. © 2017 American Society for Nutrition.

  11. Chromium, zinc and magnesium status in type 1 diabetes.

    Science.gov (United States)

    Lin, Ching-Chiang; Huang, Yeou-Lih

    2015-11-01

    Chromium, zinc, and magnesium are involved in insulin signal transduction, glucose metabolism, and cellular antioxidative defense. This review details the statuses of chromium, zinc, and magnesium in type 1 diabetes patients. Blood levels of trace elements (especially magnesium and zinc) were lower in type 1 diabetes patients than in controls and were even lower in type 1 diabetes patients with poor glycemic control. Studies with mouse models have shown that chromium and magnesium supplementation alleviated diabetes-induced complications and improved glycemic control. Many studies indicated positive correlations between decreased levels of serum chromium, zinc, and magnesium and poor glycemic control. The supplementation of type 1 diabetes patients with zinc, magnesium, and chromium may help to control diabetes and prevent diabetes-related oxidative injuries, but require further study.

  12. A Review of Hard Palate Fracture Repair Techniques.

    Science.gov (United States)

    Moss, William J; Kedarisetty, Suraj; Jafari, Aria; Schaerer, Daniel E; Husseman, Jacob W

    2016-02-01

    Hard palate trauma is a relatively infrequent occurrence compared with other craniofacial injuries. Several techniques of hard palate fracture repair have been described. To date, there is no consensus on the optimal management of this type of fracture. The purpose of this study was to compile and analyze studies describing hard palate fracture repair techniques with outcomes data. A systematic review of the Medline, Scopus, and Web of Science databases was performed for articles describing hard palate fracture repair techniques. Eight articles were ultimately included in the review. Of the collective 310 fractures reported, postoperative malocclusion occurred in 21 of 235 cases (8.9%) and other complications occurred in 13 of 299 cases (4.3%). The most important variability in technique was the method of palatal vault stabilization. Three studies described wiring techniques, 3 described internal fixation techniques, and 2 described external fixation techniques. Studies describing internal fixation techniques reported higher rates of wound complications. Proponents of rigid internal fixation believe that this technique provides better fracture reduction. External fixation techniques appear to impart low rates of wound complications, but their overall effectiveness remains in question. Hard palate fractures are associated with high rates of malocclusion and wound complications. The most established methods of palatal vault stabilization are closed reduction with wiring and internal plate fixation. Depending on the fracture type, patient comorbidities, and associated injuries, either technique might be preferable in a given circumstance. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Phosphate solubilization and chromium (VI) remediation potential of Klebsiella sp. strain CPSB4 isolated from the chromium contaminated agricultural soil.

    Science.gov (United States)

    Gupta, Pratishtha; Kumar, Vipin; Usmani, Zeba; Rani, Rupa; Chandra, Avantika

    2018-02-01

    In this study, an effort was made to identify an efficient phosphate solubilizing bacterial strain from chromium contaminated agricultural soils. Based on the formation of a solubilized halo around the colonies on Pikovskaya's agar amended with chromium (VI), 10 strains were initially screened out. Out of 10, strain CPSB4, which showed significantly high solubilization zone at different chromium concentrations, was selected for further study. The strain CPSB4 showed significant plant growth promotion traits with chromium (VI) stress under in-vitro conditions in broth. The plant growth promotion activities of the strain decreased regularly, but were not completely lost with the increase in concentration of chromium up to 200 mg L(-1). On subjected to FT-IR analysis, the presence of the functional group, indicating the organic acid aiding in phosphate solubilization was identified. At an optimal temperature of 30 (°)C and pH 7.0, the strain showed around 93% chromium (VI) reduction under in-vitro conditions in broth study. In soil condition, the maximum chromium (VI) reduction obtained was 95% under in-vitro conditions. The strain CPSB4 was identified as Klebsiella sp. on the basis of morphological, biochemical and 16S rRNA gene sequencing. This study shows that the diverse role of the bacterial strain CPSB4 would be useful in the chromium contaminated soil as a good bioremediation and plant growth promoting agent as well. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Impact of the nanostructuration on the corrosion resistance and hardness of irradiated 316 austenitic stainless steels

    Science.gov (United States)

    Hug, E.; Prasath Babu, R.; Monnet, I.; Etienne, A.; Moisy, F.; Pralong, V.; Enikeev, N.; Abramova, M.; Sauvage, X.; Radiguet, B.

    2017-01-01

    The influence of grain size and irradiation defects on the mechanical behavior and the corrosion resistance of a 316 stainless steel have been investigated. Nanostructured samples were obtained by severe plastic deformation using high pressure torsion. Both coarse grain and nanostructured samples were irradiated with 10 MeV 56Fe5+ ions. Microstructures were characterized using transmission electron microscopy and atom probe tomography. Surface mechanical properties were evaluated thanks to hardness measurements and the corrosion resistance was studied in chloride environment. Nanostructuration by high pressure torsion followed by annealing leads to enrichment in chromium at grain boundaries. However, irradiation of nanostructured samples implies a chromium depletion of the same order than depicted in coarse grain specimens but without metallurgical damage like segregated dislocation loops or clusters. Potentiodynamic polarization tests highlight a definitive deterioration of the corrosion resistance of coarse grain steel with irradiation. Downsizing the grain to a few hundred of nanometers enhances the corrosion resistance of irradiated samples, despite the fact that the hardness of nanocrystalline austenitic steel is only weakly affected by irradiation. These new experimental results are discussed in the basis of couplings between mechanical and electrical properties of the passivated layer thanks to impedance spectroscopy measurements, hardness properties of the surfaces and local microstructure evolutions.

  15. 'Hard discs' associated with lumbar disc herniation: CT analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Il Kwon; Bang, Dae Hong; Yim, Jung Ik; Lee, Jae Mun; Bahk, Yong Whee [Catholic University Medical College, Seoul (Korea, Republic of)

    1989-02-15

    Thirty cases showing hard discs were collected from 206 consecutive cases of posterior disk herniation during the past one and a half years period. According to the shape of hard disk and the presence of marginal bone defect (MBD) of vertebral end plate, 30 cases could be categorized into 4 distinct groups. They were small hard disc with focal MBD (group 1), large hard disc with broad based MBD (group 2), hard disc separated from vertebral body without MBD (group 3) and hard disc fused with vertebral body without MBD (group 4). There were 14 patients in group 1. In all but one case, the hard disc and MBDs were located at the paramedial aspect of the posterior margin of the end plate. Ten (76.9%) of these had Schmorl's nodes and these were considered to represented an avulsion from the weakened bone margin as the disk herniated acutely. The posterior longitudinal ligament seemed to have prevented detachment of the bony fragment. Group 2 included 2 patients and CT findings as well as plain X-ray features were identical to a limbus vertebra. This was considered to represent passive displacement of bony fragment by the intravertebral herniation of the disk. Nine patients belonged to group 3 and represent dystrophic calcifications of herniated disk. Group 4 included 5 patients and was disclosed as a simple osteophyte. From our study, it was concluded; (1) that the hard disc seen in lumbar CT scan was probably the results of the detachment of a bone fragment from the vertebral end plate which has an underlying weak area due to the herniated disc as well as a calcification or osteophyte formation and (2) specific terms (avulsed fragment, limbus vertebra, calcification or spur formation) is more preferable to use than hard disc which is inaccurate.

  16. Improved Corrosion Resistance of Pulse Plated Nickel through Crystallisation Control

    DEFF Research Database (Denmark)

    Tang, Peter Torben; Watanabe, Tohru; Andersen, Jens Enevold Thaulov

    1995-01-01

    When electrodeposition of nickel is used for corrosion protection of steel two aspects are important. The porosity of the coating and the resistance against corrosion provided by the coating itself. Using simple pulsed current (PC) plating, the size of the deposited crystals can be significantly...... smaller, thereby reducing porosity correspondingly. This usually also leads to improved hardness of the coating. Introducing pulse reversal (PR) plating, the most active crystals are continuously dissolved during the anodic pulse, providing a coating with improved subsequent corrosion resistance in almost...... any corrosive environment. This correlation between film texture and corrosion resistance will be discussed....

  17. Dissolution of chromium in sulfuric acid

    Directory of Open Access Journals (Sweden)

    J. P. POPIC

    2002-11-01

    Full Text Available By combining electrochemical corrosion rate measurements and spectrophotometric analysis of the electrolyte it was shown that at room temperature chromium dissolves in deaerated 0.1 M Na2SO4 + H2SO4 (pH 1 solution as Cr(II and Cr(III ions in he ratio Cr(II : Cr(III @ 7 : 1. This process was stable over 4 h without any detectable change. The total corrosion rate of chromium calculated from the analytical data is about 12 times higher, than that determined electrochemically by cathodic Tafel line extrapolation to the corrosion potential. This finding was confirmed by applying the weight-loss method for the determination of the corrosion rate. This enormous difference between these experimentally determined corrosion rates can be explained by the rather fast, “anomalous” dissolution process proposed by Kolotyrkin and coworkers (chemical reaction of Cr with H2O molecules occurring simultaneously with the electrochemical corrosion process.

  18. Chromium(VI) bioremediation by probiotics.

    Science.gov (United States)

    Younan, Soraia; Sakita, Gabriel Z; Albuquerque, Talita R; Keller, Rogéria; Bremer-Neto, Hermann

    2016-09-01

    Chromium is a common mineral in the earth's crust and can be released into the environment from anthropogenic sources. Intake of hexavalent chromium (Cr(VI)) through drinking water and food causes toxic effects, leading to serious diseases, and is a commonly reported environmental problem. Microorganisms can mitigate or prevent the toxic effects caused by heavy metals in addition to having effective resistance mechanisms to prevent cell damage and bind to these metals, sequestering them from the cell surface and removing them from the body. Species of Lactobacillus, Streptococcus, Bacillus and Bifidobacterium present in the human mouth and gut and in fermented foods have the ability to bind and detoxify some of these substances. This review address the primary topics related to Cr(VI) poisoning in animals and humans and the use of probiotics as a way to mitigate or prevent the toxic effects caused by Cr(VI). Further advances in the genetic knowledge of such microorganisms may lead to discoveries which will clarify the most active microorganisms that act as bioprotectants in bodies exposed to Cr(VI) and are an affordable option for people and animals intoxicated by the oral route. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  19. Photon technology. Hard photon technology; Photon technology. Hard photon gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    Research results of hard photon technology have been summarized as a part of novel technology development highly utilizing the quantum nature of photon. Hard photon technology refers to photon beam technologies which use photon in the 0.1 to 200 nm wavelength region. Hard photon has not been used in industry due to the lack of suitable photon sources and optical devices. However, hard photon in this wavelength region is expected to bring about innovations in such areas as ultrafine processing and material synthesis due to its atom selective reaction, inner shell excitation reaction, and spatially high resolution. Then, technological themes and possibility have been surveyed. Although there are principle proposes and their verification of individual technologies for the technologies of hard photon generation, regulation and utilization, they are still far from the practical applications. For the photon source technology, the laser diode pumped driver laser technology, laser plasma photon source technology, synchrotron radiation photon source technology, and vacuum ultraviolet photon source technology are presented. For the optical device technology, the multi-layer film technology for beam mirrors and the non-spherical lens processing technology are introduced. Also are described the reduction lithography technology, hard photon excitation process, and methods of analysis and measurement. 430 refs., 165 figs., 23 tabs.

  20. Assessment of corrosion resistance of cast cobalt- and nickel-chromium dental alloys in acidic environments.

    Science.gov (United States)

    Mercieca, Sven; Caligari Conti, Malcolm; Buhagiar, Joseph; Camilleri, Josette

    2017-10-26

    The aim of this study was to compare the degradation resistance of nickel-chromium (Ni-Cr) and cobalt-chromium (Co-Cr) alloys used as a base material for partial dentures in contact with saliva. Wiron® 99 and Wironit Extra-Hard® were selected as representative casting alloys for Ni-Cr and Co-Cr alloys, respectively. The alloys were tested in contact with deionized water, artificial saliva and acidified artificial saliva. Material characterization was performed by X-ray diffractometry (XRD) and microhardness and nanohardness testing. The corrosion properties of the materials were then analyzed using open circuit potential analysis and potentiodynamic analysis. Alloy leaching in solution was assessed by inductively coupled plasma mass spectrometry techniques. Co-Cr alloy was more stable than the Ni-Cr alloy in all solutions tested. Leaching of nickel and corrosion attack was higher in Ni-Cr alloy in artificial saliva compared with the acidified saliva. The corrosion resistance of the Co-Cr alloy was seen to be superior to that of the Ni-Cr alloy, with the former exhibiting a lower corrosion current in all test solutions. Microstructural topographical changes were observed for Ni-Cr alloy in contact with artificial saliva. The Ni-Cr alloy exhibited microstructural changes and lower corrosion resistance in artificial saliva. The acidic changes did not enhance the alloy degradation. Ni-Cr alloys are unstable in solution and leach nickel. Co-Cr alloys should be preferred for clinical use.

  1. Pulpal thermal responses to an erbium,chromium: YSGG pulsed laser hydrokinetic system.

    Science.gov (United States)

    Rizoiu, I; Kohanghadosh, F; Kimmel, A I; Eversole, L R

    1998-08-01

    Laser systems are known to raise pulpal temperatures when applied to tooth surfaces. Dental biocalcified tissues can be cut with an erbium,chromium:yttrium-scandium-gallium-garnet laser-powered hydrokinetic system. This device is effective for caries removal and cavity preparation in vitro. Pulpal monitoring of temperature changes during hard tissue cutting by a hydrokinetic system have not been reported. This study compared the effects of hydrokinetic system, dry bur, and wet bur tooth cutting on pulpal temperature. In vivo thermocouple intrapulpal measurements were made on cuspid teeth in anesthetized beagle dogs. In vitro measurements were made on extracted human molar teeth preserved in high-salt solution and later rinsed in phosphate-buffered saline (pH 7.4) to simulate in vivo conditions. The hydrokinetic system was compared with conventional air-turbine-powered bur cutting. The hydrokinetic system cuts and bur preparations were randomly made on the buccal surfaces at the cervical one third of the crown and extended until exposure of the pulp was confirmed clinically. Pulpal temperatures associated with the hydrokinetic system either showed no change or decreased by up to 2 degrees C. Wet bur preparations resulted in a 3 degrees to 4 degrees C rise. With dry bur preparations, a 14 degrees C rise in temperature was recorded. Under the conditions of this study, the erbium,chromium:yttrium-scandium-gallium-garnet laser-powered hydrokinetic system, when used for cavity preparation, had no apparent adverse thermal effect as measured in the pulp space.

  2. Corrosion resistance enhancement of SAE 1020 steel after Chromium implantation by nitrogen ion recoil

    Directory of Open Access Journals (Sweden)

    Geraldo Francisco Gomes

    2005-12-01

    Full Text Available SAE 1020 construction steel is widely used as mortar reinforcement and small machine parts, but aside good surface properties as high ductility, hardness and wear resistance, its surface is prone to severe corrosion. As it is known, Chromium in amount over 12%-13% in the Fe alloys renders them resistance to several corrosive attacks. SAE 1020 samples were recovered with Chromium film and then bombarded either by nitrogen Ion Beam (IB or Plasma Immersion Ion Implantation (PIII to recoil implant Cr atoms in the Fe matrix. Samples treated by 100 keV N+ IB showed irregular, thin Cr profile, remaining a part of the film on the surface, to about 10 nm. Samples treated by 40 kV N PIII presented Cr layer of about 18% at., ranging to around 90 nm. Cr of the film was implanted in the Fe matrix in an almost flat profile. Results of corrosion test showed good performance of the PIII treated sample. The IB treated sample showed some enhancement over the non-treated reference and the only Cr film deposited sample showed no modification on the corrosion behavior as compared to the non-treated reference sample.

  3. 40 CFR 424.70 - Applicability; description of the electrolytic chromium subcategory.

    Science.gov (United States)

    2010-07-01

    ... electrolytic chromium subcategory. 424.70 Section 424.70 Protection of Environment ENVIRONMENTAL PROTECTION... Electrolytic Chromium Subcategory § 424.70 Applicability; description of the electrolytic chromium subcategory. The provisions of this subpart are applicable to discharges resulting from the manufacture of chromium...

  4. Electrochemical modification of chromium surfaces using 4-nitro- and4-fluorobenzenediazonium salts

    DEFF Research Database (Denmark)

    Hinge, Mogens; Cecatto, Marcel; Kingshott, Peter

    2009-01-01

    Chromium surfaces can be electrografted with organic surface films using 4-nitro- or 4-fluorobenzenediazonium salts, despite the fact that the surfaces are covered with a protective chromium oxide layer......Chromium surfaces can be electrografted with organic surface films using 4-nitro- or 4-fluorobenzenediazonium salts, despite the fact that the surfaces are covered with a protective chromium oxide layer...

  5. Hexavalent Chromium: Analysis of the Mechanism of Groundwater Contamination in a Former Industrial Site in the Province of Vicenza (Northern Italy

    Directory of Open Access Journals (Sweden)

    Valentina Accoto

    2017-01-01

    Full Text Available The study consisted in the analysis of the mobilization mechanisms of hexavalent chromium (Cr(VI into groundwater from a decommissioned contaminated factory. The site is located in the Province of Vicenza and formerly was a chrome-plating plant. The subsoil consists predominantly of gravelly deposits with a thickness of at least one hundred meters. An unconfined aquifer is present with water table at about 23 m depth bgl. During the seven years of monitoring (2008-2014, the fluctuation of groundwater level was more than 6 m; hydraulic conductivity is about 1.0E-03 m/s and groundwater seepage velocity about 12 m/day. At the area of the source of contamination, the unsaturated soil is contaminated by hexavalent chromium throughout the thickness: concentrations range from 200 to 500 mg/kg. At the bottom of zone of groundwater level fluctuation, the hexavalent chromium concentration decreases to below the detection limit. The available data (e.g. hexavalent chromium concentrations in groundwater, groundwater level, local rainfall give the opportunity to assess the effects, on the magnitude of groundwater contamination, of the effective infiltration versus the fluctuation of groundwater level. The main analysis was performed on a statistical basis, in order to find out which of the two factors was most likely related to the periodic peaks of hexavalent chromium concentration in groundwater. Statistical analysis results were verified by a mass balance. Data show that at the site both the effective infiltration through the unsaturated zone and the leaching of soil contaminated by groundwater, when it exceeds a certain piezometric level, lead to peak concentrations of hexavalent chromium, even if with characteristics and effects different.

  6. Microstructure and wear resistance of high chromium cast iron containing niobium

    Directory of Open Access Journals (Sweden)

    Zhang Zhiguo

    2014-05-01

    Full Text Available In the paper, the effect of niobium addition on the microstructure, mechanical properties and wear resistance of high chromium cast iron has been studied. The results show that the microstructure of the heat-treated alloys is composed of M7C3 and M23C6 types primary carbide, eutectic carbide, secondary carbide and a matrix of martensite and retained austenite. NbC particles appear both inside and on the edge of the primary carbides. The hardness of the studied alloys maintains around 66 HRC, not significantly affected by the Nb content within the selected range of 0.48%-0.74%. The impact toughness of the alloys increases with increasing niobium content. The wear resistance of the specimens presents little variation in spite of the increase of Nb content under a light load of 40 N. However, when heavier loads of 70 and 100 N are applied, the wear resistance increases with increasing Nb content.

  7. Chromium and copper influence on the nodular cast iron with carbides microstructure

    Directory of Open Access Journals (Sweden)

    G. Gumienny

    2010-10-01

    Full Text Available In this paper chromium to 1,00% and copper to 1,50% influence at constant molybdenum content of about 1,50% on the nodular cast ironwith carbides microstructure has been presented. It was found, that as a result of synergic addition of above-mentioned elements there isthe possibility obtaining an ausferrite in nodular cast iron with carbides castings. Conditions have been given, when in nodular cast iron with carbides at cooling at first in the form, then air-cooling austenite transformation to upper bainite, its mixture with lower bainite, martensite or ausferrite takes place. Transformations proceed during cooling and the crystallization of cast iron have been determined and the casting hardness has been presented.

  8. The Plate Tectonics Project

    Science.gov (United States)

    Hein, Annamae J.

    2011-01-01

    The Plate Tectonics Project is a multiday, inquiry-based unit that facilitates students as self-motivated learners. Reliable Web sites are offered to assist with lessons, and a summative rubric is used to facilitate the holistic nature of the project. After each topic (parts of the Earth, continental drift, etc.) is covered, the students will…

  9. Create Your Plate

    Medline Plus

    Full Text Available ... meal-planning, In this section Food Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart-Healthy Foods ... your year-end donation today and help fight diabetes. Donate Today We Can Help - we-can-help. ...

  10. Create Your Plate

    Medline Plus

    Full Text Available ... 1 Type 2 About Us Online Community Meal Planning Sign In Search: Search More Sites Search ≡ Are ... Fitness Home Food MyFoodAdvisor Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten ...

  11. Create Your Plate

    Medline Plus

    Full Text Available ... to curing diabetes and better treatments for those living with diabetes. Other Ways to Give Become a ... glucose levels and lose weight. With this method, you fill your plate with more non-starchy veggies and smaller portions of starchy foods ...

  12. Create Your Plate

    Medline Plus

    Full Text Available ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ... Donations Travel bookings completed through Hotels.com give 5% back to the Association. » « Connect With Us Register ...

  13. Create Your Plate

    Medline Plus

    Full Text Available ... Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To ... Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy ... Desserts Fitness Exercise & Type 1 Diabetes Get Started Safely Get And ...

  14. Create Your Plate

    Medline Plus

    Full Text Available ... Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know ... Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning ... Can I Drink? Fruit Dairy Food ...

  15. Create Your Plate

    Medline Plus

    Full Text Available ... Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning What Can I Eat? Making Healthy Food Choices Diabetes Superfoods Non-starchy Vegetables Grains and Starchy Vegetables Fats Alcohol What Can I Drink? Fruit Dairy Food ...

  16. Create Your Plate

    Medline Plus

    Full Text Available ... Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get Started Safely Get And ... manage portion control wherever you are. Now, our best-selling, sectioned to-go plate with easy-sealing ...

  17. Create Your Plate

    Medline Plus

    Full Text Available ... portion control wherever you are. Now, our best-selling, sectioned to-go plate with easy-sealing lid ... We Can Help - we-can-help.html Chat Online Chat Closed engagement en -- Free Type 2 Education ...

  18. Create Your Plate

    Medline Plus

    Full Text Available ... tax-deductible gift today can fund critical diabetes research and support vital diabetes education services that improve the ... way to manage your blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ...

  19. Effect of Heat Treatment on the Hardness and Wear of Grinding Balls

    Science.gov (United States)

    Aissat, Sahraoui; Sadeddine, Abdelhamid; Bradai, Mohand Amokrane; Younes, Rassim; Bilek, Ali; Benabbas, Abderrahim

    2017-09-01

    The effect quenching and tempering by different regimes on Rockwell hardness and wear processes of grinding balls 50 and 70 mm in diameter made of two melts of chromium-molybdenum cast iron is studied. The heating temperature for quenching is 850, 950, and 1050°C; the tempering temperature is 250, 400, and 600°C. Iron is analyzed in an electron microscope. Diffraction patterns are obtained. A model of cast iron wear is suggested and compared to the Davis model and to experimental results. An optimum heat treatment regime is proposed.

  20. Association of muscle hardness with muscle tension dynamics: a physiological property.

    Science.gov (United States)

    Murayama, Mitsuyoshi; Watanabe, Kotaro; Kato, Ryoko; Uchiyama, Takanori; Yoneda, Tsugutake

    2012-01-01

    This study aimed to investigate the relationship between muscle hardness and muscle tension in terms of length-tension relationship. A frog gastrocnemius muscle sample was horizontally mounted on the base plate inside a chamber and was stretched from 100 to 150% of the pre-length, in 5% increments. After each step of muscle lengthening, electrical field stimulation for induction of tetanus was applied using platinum-plate electrodes positioned on either side of the muscle submerged in Ringer's solution. The measurement of muscle hardness, i.e., applying perpendicular distortion, was performed whilst maintaining the plateau of passive and tetanic tension. The relationship between normalised tension and normalised muscle hardness was evaluated. The length-hardness diagram could be created from the modification with the length-tension diagram. It is noteworthy that muscle hardness was proportional to passive and total tension. Regression analysis revealed a significant correlation between muscle hardness and passive and total tension, with a significant positive slope (passive tension: r = 0.986, P hardness depends on muscle tension in most ranges of muscle length in the length-tension diagram.

  1. Synthesis of peptide-oligonucleotide conjugates for chromium coordination.

    Science.gov (United States)

    Civitello, E R; Leniek, R G; Hossler, K A; Haebe, K; Stearns, D M

    2001-01-01

    The synthesis of the first peptide-oligonucleotide conjugate designed to coordinate chromium(III) is reported. The overall goal of this work is to synthesize di-deoxynucleotides tethered with chromium(III)-coordinating appendages to model chromium-DNA-protein cross-links, which are a type of DNA lesion that may be involved in chromium-induced cancers. The conjugate dGp(NHCH(2)CH(2)S-Ac-Gly-Ser-Gly-OH)G was made by coupling the peptide, ClAc-Gly-Ser-Gly-OH, and dinucleotide, dGp(NHCH(2)CH(2)SH)G, through a thioether moiety. The conjugate was characterized by HPLC and mass spectrometry. Previously reported methods for small-scale solid-phase synthesis of peptides and dinucleotide were unsuitable; therefore, gram-scale solution-phase methods were developed. We also report the gram-scale syntheses of two other serine-containing peptides, ClAc-betaAla-Ser-Gly-OH and ClAc-Ser-Gly-OH, and three histidine-containing peptides, ClAc-Gly-His-Gly-OH, ClAc-betaAla-His-Gly-OH, and ClAc-His-Gly-OH. The synthesis and characterization of chromium-containing peptide-oligonucleotide conjugates will ultimately help us to understand chromium-DNA interactions at a molecular level, which is necessary before we can determine how chromium causes cancer.

  2. Investigation of corrosion and wear mechanisms in hard material-reinforced duplex steel coatings; Untersuchungen zum Korrosions- und Verschleissverhalten von hartstoffverstaerkten `Duplex`-Schutzschichten. Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Bouaifi, B. [Technische Univ. Clausthal, Clausthal-Zellerfeld (Germany). Inst. fuer Schweisstechnik und Trennende Fertigungsverfahren; Goellner, J. [Technische Univ. Magdeburg (Germany). Inst. fuer Werkstofftechnik und Werkstoffpruefung

    1998-09-30

    The hard-material reinforced duplex steel coatings were deposited by plasma arc two-powder surfacing. By varying the angle of the hard materials feeding process, the deposition of the carbides was optimized so that they are deposited into the matrix in the trailing zone of the welding torch under conditions of very low thermal effects near the freezing point of the weld pool. Microstructural studies revealed that the deposition of the hard materials prevents devlopment of the typical, ferritic-austenitic microstructure of duplex steels. Due to a dissolution and diffusion process, the microstructure of the matrix takes up carbon and chromium or tungsten, depending on the carbide, thus enhancing the austenitic material in the microstructure. The wear behaviour of the surface deposits was found to be very good, wear being reduced by a factor of 6, irrespective of the type of carbide. The friction-affected surfaces showed no dissolving effects or cracking. The corrosion behaviour in sulfuric acid is also good. The welded deposits exhibited the typical behaviour of a passive material. Wear mechanisms slightly reduce the resistance. The behaviour of various specimens in artificial seawater could be distinctly assessed. Small grain fractions and pre-heating temperatures of 100 C have a beneficial effect on the corrosion resistance. The technique recommends itself for applications such as coatings for baffle plates used in flue gas desulfurisation, pipes, pump components, flanges or nozzles, or for recurrent coating of system components affected by abrasive corrosion. (orig./CB) [Deutsch] Zur Herstellung hartstoffverstaerkter Duplex-Beschichtungen wurde das Plasma-Zwei-Pulver-Auftragschweissverfahren verwendet. Hierbei wurde durch Variation des Zufuhrwinkels der Hartstoffe der Einbringungsort der Karbide optimiert, so dass diese im Nachlauf des Schweissbrenners mit sehr geringer thermischer Beeinflussung im erstarrungsnahen Schmelzbadbereich in die Matrix eingelagert

  3. The hardness of synthetic products obtained from cooled and crystallized basaltic melts (in Romanian

    Directory of Open Access Journals (Sweden)

    Daniela Ogrean

    2001-04-01

    Full Text Available The Hardness of Synthetic Products Obtained from Cooled and Crystallized Basaltic Melts. Hardness is one of the main properties of the products obtained from cooled and crystallized basaltic melts under a controlled thermal regime. It influences the abrasion tear resistance of the resulted material. The microhardness measurements on the samples (bricks, boards, gutters, armour plates, tubes indicated Vickers hardness value between 757–926 for the materials obtained from Şanovita basalts (Timiş district and between 539–958 respectively, in case of the Racoş basalts (Braşov district. There is a certain variation of the hardness within the same sample, in various measurement points, within the theoretical limits of the hardnesses of the pyroxenes and that of the spinels.

  4. Development of analytical procedures for determination of total chromium by quadrupole ICP-MS and high-resolution ICP-MS, and hexavalent chromium by HPLC-ICP-MS, in different materials used in the automotive industry.

    Science.gov (United States)

    Séby, F; Gagean, M; Garraud, H; Castetbon, A; Donard, O F X

    2003-10-01

    A European directive was recently adopted limiting the use of hazardous substances such as Pb, Hg, Cd, and Cr(VI) in vehicle manufacturing. From July 2003 a maximum of 2 g Cr(VI) will be authorised per vehicle in corrosion-preventing coatings of key components. As no standardised procedures are available to check if produced vehicles are in agreement with this directive, the objective of this work was to develop analytical procedures for total chromium and Cr(VI) determination in these materials. The first step of this study was to optimise digestion procedures for total chromium determination in plastic and metallic materials by inductively coupled plasma mass spectrometry (ICP-MS). High resolution (HR) ICP-MS was used to examine the influence of polyatomic interferences on the detection of the (52)Cr(+) and (53)Cr(+) isotopes. If there was strong interference with m/ z 52 for plastic materials, it was possible to use quadrupole ICP-MS for m/ z 53 if digestions were performed with HNO(3)+H(2)O(2). This mixture was also necessary for digestion of chromium from metallic materials. Extraction procedures in alkaline medium (NH(4)(+)/NH(3) buffer solution at pH 8.9) assisted by sonication were developed for determining Cr(VI) in four different corrosion-preventing coatings by HPLC-ICP-MS. After optimisation and validation with the only solid reference material certified for its Cr(VI) content (BCR 545; welding dusts), the efficiency of this extraction procedure for screw coatings was compared with that described in the EN ISO 3613 standard generally used in routine laboratories. For coatings comprising zinc and aluminium passivated in depth with chromium oxides the extraction procedure developed herein enabled determination of higher Cr(VI) concentrations. This was also observed for the screw covered with a chromium passivant layer on zinc-nickel. For coating comprising a chromium passivant layer on alkaline zinc the standardized extraction procedure was more efficient

  5. Corrosion kinetics of 316L stainless steel bipolar plate with chromiumcarbide coating in simulated PEMFC cathodic environment

    Directory of Open Access Journals (Sweden)

    N.B. Huang

    Full Text Available Stainless steel with chromium carbide coating is an ideal candidate for bipolar plates. However, the coating still cannot resist the corrosion of a proton exchange membrane fuel cell (PEMFC environment. In this work, the corrosion kinetics of 316L stainless steel with chromium carbide is investigated in simulated PEMFC cathodic environment by combining electrochemical tests with morphology and microstructure analysis. SEM results reveal that the steel’s surface is completely coated by Cr and chromium carbide but there are pinholes in the coating. After the coated 316L stainless steel is polarized, the diffraction peak of Fe oxide is found. EIS results indicate that the capacitive resistance and the reaction resistance first slowly decrease (2–32 h and then increase. The potentiostatic transient curve declines sharply within 2000 s and then decreases slightly. The pinholes, which exist in the coating, result in pitting corrosion. The corrosion kinetics of the coated 316L stainless steel are modeled and accords the following equation: i0 = 7.6341t−0.5, with the corrosion rate controlled by ion migration in the pinholes. Keywords: PEMFC, Metal bipolar plate, Chromium carbide coating, Corrosion kinetics, Pitting corrosion

  6. Hair chromium as an index of chromium exposure of tannery workers.

    OpenAIRE

    Randall, J A; Gibson, R S

    1989-01-01

    The use of hair chromium (Cr) concentrations as an index of Cr exposure of tannery workers was investigated. As has been shown earlier, Cr from Cr III compounds used in the leather tanning industry is absorbed because concentrations of Cr in serum and urine of tannery workers are significantly increased compared with corresponding concentrations for unexposed controls. Hair samples were collected from 71 male tannery workers from four southern Ontario tanneries and from 53 male controls not e...

  7. Characterization of Rubbers from Spherical Punch - Plate Indentation Tests

    Directory of Open Access Journals (Sweden)

    Florina Carmen Ciornei

    2016-12-01

    Full Text Available Rubber plates with different compositions and hardness were tested by continuous indentation, using a spherical punch and hysteretic phenomenon was evidenced. The experimental data interpolation with polynomial functions is accurate and permits estimation of the lost work during loading cycles. The interpolation by power law functions is more convenient by using less parameters and having a form accepted in literature. From the rubbers tested, two were considered to present good damping properties.

  8. Removal of Hexavalent Chromium from Aqueous Solution by Modified Holly Sawdust: A Study of Equilibrium and Kinetics

    Directory of Open Access Journals (Sweden)

    S. Azizian

    2010-01-01

    Full Text Available Introduction & Objective: Industrial wastewaters including heavy metals, are among the important sources of environmental pollution. Heavy metals such as chromium are found in plating wastewater and is harmful for human health and environment. The purpose of the present study was to investigate the absorption of heavy metals such as chromium onto modified holly sawdust as an cheaper absorbent. Materials & Methods: This study was a fundamental- application study done in Hamadan University of Medical Sciences, hygiene faculty water and wastewater chemistry laboratory. This study investigated the removal of hexavalent chromium by using modified holly sawdust with pH changes ,contact time ,absorbent dose and Cr(VI concentrations in batch system. Then the result was analyzed by Excel software.Results: The results showed that the removal efficiency decrease is accompanied by the increase of pH and initial chromium concentration. pH increase from 2 to 12(equilibrium time= 180 min, adsorbent dose= 0.6g/100CC, Cr(VI concentrations= 60 mg/L,leaded to the removal efficiency decrease from 99.67 % to 29.78 %. Also removal efficiency decreased from 99.37 % to 40.24 % after increasing the initial chromium concentrations from 20 mg/L to 100 mg/L. Moreover the results showed the removal efficiency increased after increasing the adsorbent dose and contact time. By increasing adsorbent dose from 0.2 g/100CC to 1 g/100CC, the removal efficiency increased from 34.65 % to 99.76 %.Additionally, the removal efficiency increased from 48.53%to 99.76% by increasing contact time from 5 mins to 180 mins. Experimental isotherms and kinetics models were assessed by Langmuir and Freundlich isotherms and pseudo-first-order and pseudo-second-order kinetics models. The results showed that the data were acceptably explained acceptably by Langmuir isotherms and pseudo-second-order kinetics models respectively.Conclusion: The results showed that the removal of hexavalent chromium

  9. Hard-phase engineering in hard/soft nanocomposite magnets

    Science.gov (United States)

    Poudyal, Narayan; Rong, Chuanbing; Vuong Nguyen, Van; Liu, J. Ping

    2014-03-01

    Bulk SmCo/Fe(Co) based hard/soft nanocomposite magnets with different hard phases (1:5, 2:17, 2:7 and 1:3 types) were fabricated by high-energy ball-milling followed by a warm compaction process. Microstructural studies revealed a homogeneous distribution of bcc-Fe(Co) phase in the matrix of hard magnetic Sm-Co phase with grain size ⩽20 nm after severe plastic deformation and compaction. The small grain size leads to effective inter-phase exchange coupling as shown by the single-phase-like demagnetization behavior with enhanced remanence and energy product. Among the different hard phases investigated, it was found that the Sm2Co7-based nanocomposites can incorporate a higher soft phase content, and thus a larger reduction in rare-earth content compared with the 2:17, 1:5 and 1:3 phase-based nanocomposite with similar properties. (BH)max up to 17.6 MGOe was obtained for isotropic Sm2Co7/FeCo nanocomposite magnets with 40 wt% of the soft phase which is about 300% higher than the single-phase counterpart prepared under the same conditions. The results show that hard-phase engineering in nanocomposite magnets is an alternative approach to fabrication of high-strength nanocomposite magnets with reduced rare-earth content.

  10. The Study of Heat Treatment Effects on Chromium Carbide Precipitation of 35Cr-45Ni-Nb Alloy for Repairing Furnace Tubes

    Directory of Open Access Journals (Sweden)

    Nakarin Srisuwan

    2016-01-01

    Full Text Available This paper presents a specific kind of failure in ethylene pyrolysis furnace tubes. It considers the case in which the tubes made of 35Cr-45Ni-Nb high temperature alloy failed to carburization, causing creep damage. The investigation found that used tubes became difficult to weld repair due to internal carburized layers of the tube. The microstructure and geochemical component of crystallized carbide at grain boundary of tube specimens were characterized by X-ray diffractometer (XRD, scanning electron microscopy (SEM with back-scattered electrons mode (BSE, and energy dispersive X-ray spectroscopy (EDS. Micro-hardness tests was performed to determine the hardness of the matrix and the compounds of new and used tube material. The testing result indicated that used tubes exhibited a higher hardness and higher degree of carburization compared to those of new tubes. The microstructure of used tubes also revealed coarse chromium carbide precipitation and a continuous carbide lattice at austenite grain boundaries. However, thermal heat treatment applied for developing tube weld repair could result in dissolving or breaking up chromium carbide with a decrease in hardness value. This procedure is recommended to improve the weldability of the 35Cr-45Ni-Nb used tubes alloy.

  11. Investigation on the structural and mechanical properties of anti-sticking sputtered tungsten chromium nitride films

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Tai-Nan [Chemical Engineering Division, Institute of Nuclear Energy Research, Taiwan, ROC (China); Han, Sheng [Department of Leisure and Recreation Management, National Taichung University of Science and Technology, Taiwan, ROC (China); Weng, Ko-Wei, E-mail: kowei@nqu.edu.tw [Department of Electronic Engineering, National Quemoy University, Taiwan, ROC (China); Lee, Chin-Tan [Department of Electronic Engineering, National Quemoy University, Taiwan, ROC (China)

    2013-02-01

    Tungsten chromium nitride (WCrN) thin films are prepared by dual-gun co-sputter process. As the surface coatings on the molding die for glass forming, WCrN films show less deterioration at high temperature than the conventional CrN coating. WCrN thin films are deposited via the reactive co-sputtering of Cr/W targets. The working pressure is kept at 2.66 Pa and the argon/nitrogen ratio is 10. Applied power of chromium is fixed and the applied power of tungsten is varied. Experimental results indicate that the atomic ratio of tungsten in the films increases with the applied power of tungsten. The dominant crystalline phase is chromium nitride when the tungsten target power is below 100 W, while tungsten nitride dominates in the film structure when the tungsten target power is beyond 200 W. A dense structure with much finer particles is developed as the tungsten power is 200 W. As the power is increased to 300 W, the particles become coarser in size. The film roughness exhibits a decreasing trend at low tungsten power and then increases as the tungsten power increased up to 300 and 400 W, presumably due to the phase change from chromium nitrides to tungsten nitrides. Further annealing of the WCrN thin films is simulated as the glass molding condition to check the anti-sticking property which is a critical requirement in molding die surface coating application. The WCrN thin film coating shows good anti-sticking property at 400 °C annealing when the tungsten target power is 200 W. - Highlights: ► WCrN films are deposited by dual sputtering of pure Cr and W targets. ► The covalent bonding character of WCrN films explains the difference in hardness. ► WCrN (200 W W-target-power/400 °C-annealing) exhibits the best anti-sticking performance.

  12. Effect of solute grain boundary segregation and hardness on the ductile-to-brittle transition for a Cr-Mo low-alloy steel

    Energy Technology Data Exchange (ETDEWEB)

    Shen, D.-D. [School of Materials and Metallurgy, Wuhan University of Science and Technology, Wuhan 430081 (China); Song, S.-H. [Division of Materials Science and Engineering, Shenzhen Graduate School, Harbin Institute of Technology, Shenzhen University Town, Xili, Shenzhen 518055 (China)]. E-mail: shsonguk@yahoo.co.uk; Yuan, Z.-X. [School of Materials and Metallurgy, Wuhan University of Science and Technology, Wuhan 430081 (China); Weng, L.-Q. [Division of Materials Science and Engineering, Shenzhen Graduate School, Harbin Institute of Technology, Shenzhen University Town, Xili, Shenzhen 518055 (China)

    2005-03-15

    Combined solute grain boundary segregation and hardness effect on the ductile-to-brittle transition is examined for a P-doped 2.25Cr-1Mo steel by means of Auger electron spectroscopy (AES) in conjunction with hardness measurements, Charpy impact tests and scanning electron microscopy (SEM). During ageing at 540 deg. C after water quenching from 980 deg. C, the segregation of phosphorus, molybdenum and chromium increases and the hardness decreases with increasing ageing time. The ductile-to-brittle transition temperature (DBTT) increases with increasing phosphorus segregation and decreases with decreasing hardness. The phosphorus segregation effect is dominant until 100 h ageing and after that the hardness effect becomes dominant, making the DBTT decrease with further increasing ageing time although the segregation of phosphorus still increases strongly. The segregation of molybdenum has some effect on the DBTT decrease.

  13. Self-Lubricating Composite Containing Chromium Oxide

    Science.gov (United States)

    Dellacorte, Christopher (Inventor); Edmonds, Brian J. (Inventor)

    1999-01-01

    A self lubricating. friction and wear reducing composite material useful over a wide temperature range of from cryogenic temperature up to about 900 C. contains 60 80 wt. % of particulate Cr2O3, dispersed in a metal binder of a metal alloy containing Cr and at least 50 wt. % of Ni, Cr or a mature of Ni and Cr. It also contains 5-20 wt. % of a fluoride of at least one Group I, Group II or rare earth metal and. optionally, 5-20 wt. % of a low temperature lubricant metal, such as Ag. Au, Pt, Pd, Rh and Cu. This composite exhibits less oxidation instability and less abrasiveness than composites containing chromium carbide, is readily applied using plasma spray and can be ground and polished with a silicon carbide abrasive.

  14. Effect of vibration frequency on microstructure and performance of high chromium cast iron prepared by lost foam casting

    Directory of Open Access Journals (Sweden)

    Wen-qi Zou

    2016-07-01

    Full Text Available In the present research, high chromium cast irons (HCCIs were prepared using the lost foam casting (LFC process. To improve the wear resistance of the high chromium cast irons (HCCIs, mechanical vibration was employed during the solidification of the HCCIs. The effects of vibration frequency on the microstructure and performance of the HCCIs under as-cast, as-quenched and as-tempered conditions were investigated. The results indicated that the microstructures of the LFC-produced HCCIs were refined due to the introduction of mechanical vibration, and the hardness was improved compared to that of the alloy without vibration. However, only a slight improvement in hardness was found in spite of the increase of vibration frequency. In contrast, the impact toughness of the as-tempered HCCIs increased with an increase in the vibration frequency. In addition, the wear resistance of the HCCIs was improved as a result of the introduction of vibration and increased with an increase in the vibration frequency.

  15. Deposition of nanocrystalline nonstoichiometric chromium oxide coatings on the surface of multiwalled carbon nanotubes by chromium acetylacetonate vapor pyrolysis

    Science.gov (United States)

    Kremlev, K. V.; Ob'edkov, A. M.; Ketkov, S. Yu.; Kaverin, B. S.; Semenov, N. M.; Gusev, S. A.; Andreev, P. V.

    2017-04-01

    Nanocrystalline coatings of nonstoichiometric chromium oxide have been obtained for the first time on the surface of multiwalled carbon nanotubes (MWCNTs) by the method of metalorganic chemical-vapor deposition using chromium acetylacetonate as a precursor. The new hybrid nanomaterial (Cr2O2.4/MWCNT) has been characterized by X-ray diffraction, scanning electron microscopy, and thermogravimetric analysis. It is established that oxidation of the hybrid nanomaterial in air under soft conditions (at 380°C) leads to the formation of nanocrystalline chromium oxide (Cr2O3) on the surface of MWCNTs.

  16. Inelastic buckling of plate

    Science.gov (United States)

    Rio, G.

    This paper concerns the inelastic stability of a thin plate under in-plane loading. In Love-Kirchhoffs approximation, using Hencky's relations and the Von Mises criterion, yield the particular stress distribution across the plate thickness for elastic and elastic-plastic prestress fields. The principle of virtual work is used to study the equilibrium of the bifurcated solution. This leads to the energy relations where explicit dependence between the stability equation coefficients and the solution is carried out. In the equilibrium equation, two nonquadratic additional terms are obtained which are neglected in the classical equation. Some applications are made using Ramberg-Osgood's formula to show the importance of the additional terms.

  17. CHARACTERIZATION OF 6061 T651 ALUMINUM PLATES SUBJECTED TO HIGH-VELOCITY IMPACT LOADS

    Directory of Open Access Journals (Sweden)

    Evren ÖZŞAHİN

    2011-06-01

    Full Text Available Ballistic response of single or multi-layered metal armor systems subjected to kinetic energy pro-jectiles was investigated in many experimental, theoretical and numerical studies.In this study, 6061 T651 aluminum plates impacted by 9 mm bullets were investigated. Microstructural investigations have been carried out using optical microscopy. Microhardness values were used to determine the strength behavior of the plates. Influence of the plate thickness and impact velocity on the microstructure has been evaluated. It was concluded from the study that thinner plates are more prone to deformation hardening with high penetration depth values even at low impact velocities while thick plates are more susceptible to thermal softening with less penetration depths. Maximum hardness values were obtained just below the impact zone in both plate thicknesses.

  18. Dynamic hardness of high-strength steel and titanium alloy

    Energy Technology Data Exchange (ETDEWEB)

    Stepanov, G.; Zubov, V. [Natsional' na Akademyiya Ukrayini, Kiev (Ukraine). Inst. of Strength Problems

    2000-09-01

    Essential results of experimental studies on dynamic hardness (an average pressure on the cone face of a rigid rod at its impact indentation into the surface layer of a thick plate) of a homogeneous rolled steel (HRA) and a titanium alloy are presented in this paper. Significant influence of the impact velocity on dynamic hardness of materials tested follows from the analysis of the experimental data. Specific energy of the formation of a conical cavity (per unit volume of displaced material) decreases with an increase in the indentation velocity and the conical cavity depth. At further process of indentation, corresponding to the initial stage of penetration (the cavity depth exceeds the length of the rod conical head) the average pressure increases with the impact velocity. Combined influence of viscosity effect and rise in temperature at plastic flow should be taken into account in order to explain the above relations. (orig.)

  19. A hard X-ray nanoprobe beamline for nanoscale microscopy.

    Science.gov (United States)

    Winarski, Robert P; Holt, Martin V; Rose, Volker; Fuesz, Peter; Carbaugh, Dean; Benson, Christa; Shu, Deming; Kline, David; Stephenson, G Brian; McNulty, Ian; Maser, Jörg

    2012-11-01

    The Hard X-ray Nanoprobe Beamline (or Nanoprobe Beamline) is an X-ray microscopy facility incorporating diffraction, fluorescence and full-field imaging capabilities designed and operated by the Center for Nanoscale Materials and the Advanced Photon Source at Sector 26 of the Advanced Photon Source at Argonne National Laboratory. This facility was constructed to probe the nanoscale structure of biological, environmental and material sciences samples. The beamline provides intense focused X-rays to the Hard X-ray Nanoprobe (or Nanoprobe) which incorporates Fresnel zone plate optics and a precision laser sensing and control system. The beamline operates over X-ray energies from 3 to 30 keV, enabling studies of most elements in the periodic table, with a particular emphasis on imaging transition metals.

  20. Hardness and microplasticity of nanocrystalline and amorphous calcium phosphate coatings

    Science.gov (United States)

    Ievlev, V. M.; Kostyuchenko, A. V.; Darinskii, B. M.; Barinov, S. M.

    2014-02-01

    The hardness of thin (1.0-4.0 μm) hydroxyapatite coatings with different structures (nanocrystalline, amorphous-crystalline, and amorphous) grown by rf magnetron sputtering on Ti and Si plates has been studied using the nanoindentation method. All the grown structures are characterized by the strain which has reversible and irreversible components. The hardness of nanocrystalline coatings (about 10 GPa) corresponds to the average hardness of hydroxyapatite single crystals. The structure of nanocrystalline coatings in the indentation zone and outside it has been investigated and changes in the structure under the indenter have been revealed using high-resolution transmission electron microscopy. From a comparison of the hardnesses of coatings with different structures and based on an analysis of the intragranular structure, it has been assumed that the plastic deformation occurs according to a dislocation-free mechanism. The plastic deformation is interpreted in terms of the cluster representation of the hydroxyapatite structure and amorphous calcium phosphates of the same elemental composition and cluster-boundary sliding during the deformation.

  1. ABS polymer electroless plating through a one-step poly(acrylic acid) covalent grafting.

    Science.gov (United States)

    Garcia, Alexandre; Berthelot, Thomas; Viel, Pascal; Mesnage, Alice; Jégou, Pascale; Nekelson, Fabien; Roussel, Sébastien; Palacin, Serge

    2010-04-01

    A new, efficient, palladium- and chromium-free process for the electroless plating of acrylonitrile-butadiene-styrene (ABS) polymers has been developed. The process is based on the ion-exchange properties of poly(acrylic acid) (PAA) chemically grafted onto ABS via a simple and one-step method that prevents using classical surface conditioning. Hence, ABS electroless plating can be obtained in three steps, namely: (i) the grafting of PAA onto ABS, (ii) the copper Cu(0) seeding of the ABS surface, and (iii) the nickel or copper metallization using commercial-like electroless plating bath. IR, XPS, and SEM were used to characterize each step of the process, and the Cu loading was quantified by atomic absorption spectroscopy. This process successfully compares with the commercial one based on chromic acid etching and palladium-based seed layer, because the final metallic layer showed excellent adhesion with the ABS substrate.

  2. Recovery of Chromium (III) from Tannery wastewater | ALI AWAN ...

    African Journals Online (AJOL)

    Three aqueous oxidants, Hydrogen peroxide, Sodium Hypochlorite and Calcium Hypochlorite were employed independently in oxidizing Chromium (III) containing tannery wastewaters to soluble chromate (CrO42-) under alkaline conditions. The amount of chromate recovered was determined via spectrophotometry.

  3. Evaluation of selected wetland plants for removal of chromium from ...

    African Journals Online (AJOL)

    user

    Agro-processing industrial sector in Ethiopia is now the ... chromium from tannery wastewater treatment using .... extract was recovered through filtration. .... by microorganisms and chemisorption (Collin and .... From Tannery Waste Effluent.

  4. Arsenic, chromium, copper, iron, manganese, lead, selenium and ...

    African Journals Online (AJOL)

    Arsenic, chromium, copper, iron, manganese, lead, selenium and zinc in the tissues of the largemouth yellowfish, Labeobarbus kimberleyensis (Gilchrist and Thompson, 1913), from the Vaal Dam, South Africa, and associated consumption risks.

  5. IRIS Toxicological Review of Hexavalent Chromium (Peer Review Plan)

    Science.gov (United States)

    EPA is conducting a peer review of the scientific basis supporting the human health hazard and dose-response assessment of hexavalent chromium that will appear on the Integrated Risk Information System (IRIS) database.

  6. Molecular Mechanisms of Chromium in Alleviating Insulin Resistance

    Science.gov (United States)

    Hua, Yinan; Clark, Suzanne; Ren, Jun; Sreejayan, Nair

    2011-01-01

    Type 2 diabetes is often associated with obesity, dyslipidemia, and cardiovascular anomalies and is a major health problem approaching global epidemic proportions. Insulin resistance, a prediabetic condition, precedes the onset of frank type 2 diabetes and offers potential avenues for early intervention to treat the disease. Although lifestyle modifications and exercise can reduce the incidence of diabetes, compliance has proved to be difficult, warranting pharmacological interventions. However, most of the currently available drugs that improve insulin sensitivity have adverse effects. Therefore, attractive strategies to alleviate insulin resistance include dietary supplements. One such supplement is chromium, which has been shown reduce insulin resistance in some, but not all, studies. Furthermore, the molecular mechanisms of chromium in alleviating insulin resistance remain elusive. This review examines emerging reports on the effect of chromium, as well as molecular and cellular mechanisms by which chromium may provide beneficial effects in alleviating insulin resistance. PMID:22423897

  7. Study of effect of chromium on titanium dioxide phase transformation ...

    Indian Academy of Sciences (India)

    Administrator

    Electronic Supplementary Material. Study of effect of chromium on titanium dioxide phase transformation by A Bellifa (pp 669–677). Figure S1. Structural schemes of anatase to rutile transition. Figure S2. Analysis ATG-ATD for different samples.

  8. Synthesis and spectral properties of Chromium(III) complex of ...

    African Journals Online (AJOL)

    ISSCH) with chromium(III) chloride. The complex was characterized by molar conductance, magnetic moment, infrared, far-infrared and electronic spectra and elemental analysis. The ligand exists in keto tantomeric form and it coordinates through ...

  9. Adsorption of hexavalent chromium by graphite–chitosan binary ...

    Indian Academy of Sciences (India)

    . Graphite chitosan binary (GCB) composite was prepared for hexavalent chromium adsorption from studied water. GCB was ... Sorption mechanisms based on metal ionic interactions, intrusion/diffusion and chemisorptions onto composite.

  10. Chromium Elimination and Cannon Life Extension for Gun Tubes

    Science.gov (United States)

    2012-08-30

    erosion- resistant chrome cobalt alloy matrix with 15% tungsten. Stellite is used as M60 machine gun barrel liner. Tantalum Cobalt Tungsten...U.S. Army Research, Development and Engineering Command Chromium Elimination and Cannon Life Extension for Gun Tubes ESTCP WP-201111...DATES COVERED 00-00-2012 to 00-00-2012 4. TITLE AND SUBTITLE Chromium Elimination and Cannon Life Extension for Gun Tubes 5a. CONTRACT NUMBER 5b

  11. Effect of chromium toxicity on germination and early seedling growth ...

    African Journals Online (AJOL)

    USER

    2010-07-19

    Jul 19, 2010 ... Effect of chromium on dry weight of radicle (p <. 0.01, LSD0.05: 14.75) and hypocotyll (p < 0.01, LSD0.05: 15.28) in melon. Figure 5. Growth tolerance index (GTI: p < 0.001, LSD0.05: 5.13) in melon by affected excess chromium. involving the growth of spinach variety 'Punjab Green' in a greenhouse on silty ...

  12. Stereology of carbide phase in modified hypereutectic chromium cast iron

    Directory of Open Access Journals (Sweden)

    J. Suchoń

    2010-04-01

    Full Text Available In paper are presented results of studies of carbide phase stereology modified hypereutectic wear resistance chromium cast iron which contains carbon about 3,5% and chromium about 25%. Three substances were applied to the modification: boron carbide (B4C, ferroniobium (FeNb and mixture of ferroniobium and rare-earth (RE. The measurements of geometrical features of carbides were conducted on microsection taken from castings wich were cooled with various velocities.

  13. Chromium (V) compounds as cathode material in electrochemical power sources

    Science.gov (United States)

    Delnick, F.M.; Guidotti, R.A.; McCarthy, D.K.

    A cathode for use in a thermal battery, comprising a chromium (V) compound. The preferred materials for this use are Ca/sub 5/(CrO/sub 4/)/sub 3/Cl, Ca/sub 5/(CrO/sub 4/)OH, and Cr/sub 2/O/sub 5/. The chromium (V) compound can be employed as a cathode material in ambient temperature batteries when blended with a suitably conductive filler, preferably carbon black.

  14. Chromium Ions Improve Moisure Resistance of Epoxy Resins

    Science.gov (United States)

    St. Clair, A. K.; St. Clair, T. L.; Stoakley, D. M.; Singh, J. J.; Sprinkle, D. R.

    1986-01-01

    Broad spectrum of thermosetting epoxy resins used on commercial and military aircraft, primarily as composite matrices and adhesives. In new technique, chromium-ion containing epoxy with improved resistance to moisture produced where chromium ions believed to prevent absorption of water molecules by coordinating themselves to hydroxyl groups on epoxy chain. Anticipated that improved epoxy formulation useful as composite matrix resin, adhesive, or casting resin for applications on commercial and advanced aircraft. Improvement made without sacrifice in mechanical properties of polymer.

  15. Microstructure and Hardness of High Temperature Gas Nitrided AISI 420 Martensitic Stainless Steel

    Directory of Open Access Journals (Sweden)

    Ibrahim Nor Nurulhuda Md.

    2014-07-01

    Full Text Available This study examined the microstructure and hardness of as-received and nitrided AISI 420 martensitic stainless steels. High temperature gas nitriding was employed to treat the steels at 1200°C for one hour and four hours using nitrogen gas, followed by furnace cooled. Chromium nitride and iron nitride were formed and concentrated at the outmost surface area of the steels since this region contained the highest concentration of nitrogen. The grain size enlarged at the interior region of the nitrided steels due to nitriding at temperature above the recrystallization temperature of the steel and followed by slow cooling. The nitrided steels produced higher surface hardness compared to as-received steel due to the presence of nitrogen and the precipitation of nitrides. Harder steel was produced when nitriding at four hours compared to one hour since more nitrogen permeated into the steel.

  16. Cobalt, nickel and chromium release from dental tools and alloys.

    Science.gov (United States)

    Kettelarij, Jolinde A B; Lidén, Carola; Axén, Emmy; Julander, Anneli

    2014-01-01

    Cobalt-chromium alloys are used as casting alloys by dental technicians when producing dental prostheses and implants. Skin exposure and metal release from alloys and tools used by the dental technicians have not been studied previously. To study the release of cobalt, nickel and chromium from alloys and tools that come into contact with the skin of dental technicians. Cobalt and nickel release from tools and alloys was tested with the cobalt spot test and the dimethylglyoxime test for nickel. Also, the release of cobalt, nickel and chromium in artificial sweat (EN1811) at different time-points was assessed. Analysis was performed with inductively coupled plasma-mass spectrometry. Sixty-one tools were spot tested; 20% released nickel and 23% released cobalt. Twenty-one tools and five dental alloys were immersed in artificial sweat. All tools released cobalt, nickel and chromium. The ranges were 0.0047-820, 0.0051-10 and 0.010-160 µg/cm(2) /week for cobalt, nickel and chromium, respectively. All dental alloys released cobalt in artificial sweat, with a range of 0.0010-17 µg/cm(2) /week, and they also released nickel and chromium at low concentrations. Sensitizing metals are released from tools and alloys used by dental technicians. This may cause contact allergy and hand eczema. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Stabilization of carbon dioxide and chromium slag via carbonation.

    Science.gov (United States)

    Wu, Xingxing; Yu, Binbin; Xu, Wei; Fan, Zheng; Wu, Zucheng; Zhang, Huimin

    2017-08-01

    As the main greenhouse gas, CO2 is considered as a threat in the context of global warming. Many available technologies to reduce CO2 emission was about CO2 separation from coal combustion and geological sequestration. However, how to deal with the cost-effective storage of CO2 has become a new challenge. Moreover, chromium pollution, the treatment of which requires huge energy consumption, has attracted people's widespread attention. This study is aimed to develop the sequestration of CO2 via chromium slag. A dynamic leaching experiment of chromium slag was designed to testify the ability of CO2 adsorption onto chromium slag and to release Cr(VI) for stabilization. The results showed that the accumulative amounts of Cr(VI) were ca. 2.6 mg/g released from the chromium slag after 24 h of leaching. In addition, ca. 89 mg/g CO2 was adsorbed by using pure CO2 in the experiment at 12 h. Calcite is the only carbonate species in the post-carbonated slag analyzed by powder X-ray diffraction and thermal analysis. The approach provides the feasibility of the utilization of chromium slag and sequestration of the carbon dioxide at the same time at ordinary temperatures and pressures.

  18. Cytokine detection for the diagnosis of chromium allergy*

    Science.gov (United States)

    Martins, Luis Eduardo Agner Machado; dos Reis, Vitor Manoel Silva

    2013-01-01

    BACKGROUND Patch testing remains the gold standard method for the identification of the etiologic agent of allergic contact dermatitis. However, it is a subjective, time-consuming exam whose technique demands special care and which presents some contraindications, which hamper its use. In a recent study, we showed that the proliferation assay can suitably replace patch testing for the diagnosis of chromium allergy, which had been previously demonstrated only for nickel allergy. In this study, we try to refine the method by reducing the incubation period of cultures for lymphocyte proliferation assays in response to chromium. OBJECTIVE Develop an alternative or complementary diagnostic test for chromium allergic contact dermatitis. METHODS We compared the production of 9 cytokines (IFN-γ, IL-2, IL-4, IL-5, IL-10, IL-12, IL-13, IL-17 and RANTES) between 18 chromium-allergic patients and 19 controls. RESULTS Chromium increased the production of IFN-y, IL-5, IL-2 and IL-13 in allergic patients, but only IL-2 and especially IL-13 helped discriminate allergic patients from controls. The sensitivity, specificity and accuracy found with IL-13 were about 80%. CONCLUSIONS IL-13 and IL-2 detection may be used to diagnose chromium allergy in 2-day cultures. However, in general, the 6-day cultures seem to be superior for this purpose. PMID:24173176

  19. Evaluating trivalent chromium toxicity on wild terrestrial and wetland plants.

    Science.gov (United States)

    Lukina, A O; Boutin, C; Rowland, O; Carpenter, D J

    2016-11-01

    Elevated chromium levels in soil from mining can impact the environment, including plants. Mining of chromium is concentrated in South Africa, several Asian countries, and potentially in Northern Ontario, Canada, raising concerns since chromium toxicity to wild plants is poorly understood. In the first experiment, concentration-response tests were conducted to evaluate effects of chromium on terrestrial and wetland plants. Following established guidelines using artificial soil, seeds of 32 species were exposed to chromium (Cr(3+)) at concentrations simulating contamination (0-1000 mg kg(-1)). This study found that low levels of chromium (250 mg kg(-1)) adversely affected the germination of 22% of species (33% of all families), while higher levels (500 and 1000 mg kg(-1)) affected 69% and 94% of species, respectively, from 89% of the families. Secondly, effects on seedbanks were studied using soil collected in Northern Ontario and exposed to Cr(3+) at equivalent concentrations (0-1000 mg kg(-1)). Effects were less severe in the seedbank study with significant differences only observed at 1000 mg kg(-1). Seeds exposed to Cr(3+) during stratification were greatly affected. Seed size was a contributing factor as was possibly the seed coat barrier. This study represents an initial step in understanding Cr(3+) toxicity on wild plants and could form the basis for future risk assessments. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  20. Dissociative electron attachment to coordination complexes of chromium: chromium(0 hexacarbonyl and benzene-chromium(0 tricarbonyl

    Directory of Open Access Journals (Sweden)

    Janina Kopyra

    2017-10-01

    Full Text Available Here we report the results of dissociative electron attachment (DEA to gas-phase chromium(0 hexacarbonyl (Cr(CO6 and benzene-chromium(0 tricarbonyl ((η6-C6H6Cr(CO3 in the energy range of 0–12 eV. Measurements have been performed utilizing an electron-molecular crossed beam setup. It was found that DEA to Cr(CO6 results (under the given experimental conditions in the formation of three fragment anions, namely [Cr(CO5]−, [Cr(CO4]−, and [Cr(CO3]−. The predominant reaction channel is the formation of [Cr(CO5]− due to the loss of one CO ligand from the transient negative ion. The [Cr(CO5]− channel is visible via two overlapping resonant structures appearing in the energy range below 1.5 eV with a dominant structure peaking at around 0 eV. The peak maxima of the fragments generated by the loss of two or three CO ligands are blue-shifted and the most intense peaks within the ion yield curves appear at 1.4 eV and 4.7 eV, respectively. (η6-C6H6Cr(CO3 shows a very rich fragmentation pattern with decomposition leading to the formation of seven fragment anions. Three of them are generated from the cleavage of one, two or three CO ligand(s. The energy of the peak maxima of the [(C6H6Cr(CO2]–, [(C6H6Cr(CO]–, and [(C6H6Cr]− fragments is shifted towards higher energy with respect to the position of the respective fragments generated from Cr(CO6. This phenomenon is most likely caused by the fact that chromium–carbonyl bonds are stronger in the heteroleptic complex (η6-C6H6Cr(CO3 than in homoleptic Cr(CO6. Besides, we have observed the formation of anions due to the loss of C6H6 and one or more CO units. Finally, we found that Cr−, when stripped of all ligands, is generated through a high-energy resonance, peaking at 8 eV.

  1. Microstructure & Other Properties of Pulse-Plated Copper for Electroforming Applications

    DEFF Research Database (Denmark)

    Tang, Peter Torben; Jensen, Jens Dahl; Dam, H.C.

    2002-01-01

    Microstructure, hardness, material distribution and current efficiency were studied for various pulse patterns (both direct current, on/off and pulse reverse plating) and different bath compositions of copper sulfate and sulfuric acid, with additions of chloride. The objective was to develop a re...... a reliable copper electroforming process to provide a fine-grained and hard (above HV 125) deposit with good micro- and macrothrowing power. Potential applications include solar cell panels, tools for micro injection molding and various microelectromechanical systems (MEMS)....

  2. Chemical hardness and density functional theory

    Indian Academy of Sciences (India)

    Keywords. Hardness; softness; hard & soft acids bases (HSAB); principle of maximum hardness (PMH) density functional theory (DFT). Abstract. The concept of chemical hardness is reviewed from a personal point of view. Author Affiliations. Ralph G Pearson1. Chemistry Department, University of California, Santa Barbara, ...

  3. Experimental skin deposition of chromium on the hands following handling of samples of leather and metal

    DEFF Research Database (Denmark)

    Bregnbak, David; Thyssen, Jacob P.; Jellesen, Morten Stendahl

    2016-01-01

    Background: Chromium is an important skin sensitizer. Exposure to it has been regulated in cement, and recently in leather. Studies on the deposition of chromium ions on the skin as a result of handling different chromium-containing materials are sparse, but could improve the risk assessment...... of contact sensitization and allergic contact dermatitis caused by chromium. Objectives: To determine whether the handling of chromium-containing samples of leather and metal results in the deposition of chromium onto the skin. Methods: Five healthy volunteers participated. For 30 min, they handled samples...... of leather and metal known to contain and release chromium. Skin deposition of chromium was assessed with the acid wipe sampling technique. Results: Acid wipe sampling of the participants' fingers showed chromium deposition on the skin in all participants who had been exposed to leather (range 0.01–0.20 µg...

  4. [Chromium content in foods and dietary intake estimation in the Northwest of Mexico].

    Science.gov (United States)

    Grijalva Haro, M I; Ballesteros Vázquez, M N; Cabrera Pacheco, R M

    2001-03-01

    Chromium is an indispensable nutrient for the carbohydrates and lipids metabolism. In this study the chromium content in the twenty main foods of the diet from Northwestern Mexico was determined, as well as the daily mean intake which was estimated based on the food intake basket of this region. Chromium content was analyzed by atomic absorption spectrophotometry using the graphite furnace technique and previous digestion of foods in microwave oven. The chromium mean intake was estimated considering the chromium daily mean intake for person per day and the chromium content of the foods analyzed in this study. The range chromium content in the foods analyzed was between 0.0004 and 0.1641 microgram/g dry weight. White cheese showed the highest chromium content followed by pasta soup, wheat tortilla, bread and meat. The main foods chromium contributors in the diet were: wheat tortilla (20%), white cheese (11%), corn tortilla (11%), pasta soup (10%), milk (10%), meat (9%) and white bread (8%). The daily chromium intake was 30.43 +/- 1.6 micrograms/d. Chromium values obtained in the food analyzed are considered low. Moreover, chromium intake obtained from the diet is not enough to meet the safety and adequate daily chromium intake. Therefore, the population from the Northwestern Mexico has a suboptimal dietary chromium intake.

  5. Chromium Exposure and Hygienic Behaviors in Printing Workers in Southern Thailand

    Directory of Open Access Journals (Sweden)

    Somsiri Decharat

    2015-01-01

    Full Text Available Objectives. The main objective of this study was to assess the chromium exposure levels in printing workers. The study evaluated the airborne, serum, and urinary chromium levels and determines any correlation between level of chromium in specimen and airborne chromium levels. Material and Methods. A cross-sectional study was conducted with 75 exposed and 75 matched nonexposed subjects. Air breathing zone was measured by furnace atomic absorption spectrophotometer. Serum and urine samples were collected to determine chromium levels by graphite furnaces atomic absorption spectrometer chromium analyzer. Results and Discussion. The printing workers’ urinary chromium levels (6.86±1.93 μg/g creatinine and serum chromium levels (1.24±1.13 μg/L were significantly higher than the control group (p<0.001 and p<0.001. Work position, duration of work, personal protective equipment (PPE, and personal hygiene were significantly associated with urinary chromium level and serum chromium levels (p<0.001 and p<0.001. This study found a correlation between airborne chromium levels and urinary chromium levels (r=0.247, p=0.032. A multiple regression model was constructed. Significant predictors of urinary and serum chromium levels were shown in this study. Conclusion. Improvements in working conditions, occupational health training, and PPE use are recommended to reduce chromium exposure.

  6. Fuel cell end plate structure

    Science.gov (United States)

    Guthrie, Robin J.; Katz, Murray; Schroll, Craig R.

    1991-04-23

    The end plates (16) of a fuel cell stack (12) are formed of a thin membrane. Pressure plates (20) exert compressive load through insulation layers (22, 26) to the membrane. Electrical contact between the end plates (16) and electrodes (50, 58) is maintained without deleterious making and breaking of electrical contacts during thermal transients. The thin end plate (16) under compressive load will not distort with a temperature difference across its thickness. Pressure plate (20) experiences a low thermal transient because it is insulated from the cell. The impact on the end plate of any slight deflection created in the pressure plate by temperature difference is minimized by the resilient pressure pad, in the form of insulation, therebetween.

  7. Effect of recasting on the thickness of metal-ceramic interface of nickel-chromium and cobalt-chromium alloys

    OpenAIRE

    Mirković Nemanja; Draganjac Miroslav; Stamenković Dragoslav; Ristić Ljubiša

    2008-01-01

    Introduction/Aim. This research was done to establish recasting effects of nickel-chromium and cobalt-chromium alloys on the thickness of their metal-ceramic interface in making fixed partial dentures. Metal-ceramic interface determines their functional integrity and prevents damages on ceramics during mastication. Investigation of metal-ceramic samples is supposed to show if base metal alloys for metalceramics are successfully recycled without any risk of reduction of metal-ceramic interface...

  8. Chromium released from leather - I: exposure conditions that govern the release of chromium(III) and chromium(VI).

    Science.gov (United States)

    Hedberg, Yolanda S; Lidén, Carola; Odnevall Wallinder, Inger

    2015-04-01

    Approximately 1-3% of the adult population in Europe is allergic to chromium (Cr). A new restriction in REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) based on the ISO 17075 standard has recently been adopted in the EU to limit Cr(VI) in consumer and occupational leather products. The aim of this study was to critically assess key experimental parameters in this standard on the release of Cr(III) and Cr(VI) and their relevance for skin exposure. Four differently tanned, unfinished, leather samples were systematically investigated for their release of Cr(III) and Cr(VI) in relation to surface area, key exposure parameters, temperature, ultraviolet irradiation, and time. Although the total release of Cr was largely unaffected by all investigated parameters, except exposure duration and temperature, the Cr oxidation state was highly dynamic, with reduced amounts of released Cr(VI) with time, owing to the simultaneous release of reducing agents from the leather. Significantly more Cr(III) than Cr(VI) was released from the Cr-tanned leather for all conditions tested, and it continued to be released in artificial sweat up to at least 1 week of exposure. Several parameters were identified that influenced the outcome of the ISO 17075 test. © 2015 The Authors. Contact Dermatitis published by John Wiley & Sons Ltd.

  9. Chromium released from leather – I: exposure conditions that govern the release of chromium(III) and chromium(VI)

    Science.gov (United States)

    Hedberg, Yolanda S; Lidén, Carola; Odnevall Wallinder, Inger

    2015-01-01

    Background Approximately 1–3% of the adult population in Europe is allergic to chromium (Cr). A new restriction in REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) based on the ISO 17075 standard has recently been adopted in the EU to limit Cr(VI) in consumer and occupational leather products. Objectives The aim of this study was to critically assess key experimental parameters in this standard on the release of Cr(III) and Cr(VI) and their relevance for skin exposure. Material and methods Four differently tanned, unfinished, leather samples were systematically investigated for their release of Cr(III) and Cr(VI) in relation to surface area, key exposure parameters, temperature, ultraviolet irradiation, and time. Results Although the total release of Cr was largely unaffected by all investigated parameters, except exposure duration and temperature, the Cr oxidation state was highly dynamic, with reduced amounts of released Cr(VI) with time, owing to the simultaneous release of reducing agents from the leather. Significantly more Cr(III) than Cr(VI) was released from the Cr-tanned leather for all conditions tested, and it continued to be released in artificial sweat up to at least 1 week of exposure. Conclusions Several parameters were identified that influenced the outcome of the ISO 17075 test. PMID:25653094

  10. [Effect of recasting on the thickness of metal-ceramic interface of nickel-chromium and cobalt-chromium alloys].

    Science.gov (United States)

    2008-05-01

    This research was done to establish recasting effects of nickel-chromium and cobalt-chromium alloys on the thickness of their metal-ceramic interface in making fixed partial dentures. Metal-ceramic interface determines their functional integrity and prevents damages on ceramics during mastication. Investigation of metal-ceramic samples is supposed to show if base metal alloys for metal-ceramics are successfully recycled without any risk of reduction of metal-ceramic interface thickness. The research was performed as an experimental study. Per six metal-ceramic samples of nickel-chromium alloy (Wiron99) and cobalt-chromium alloy (Wirobond C) were made each. Alloy residues were recycled through twelve casting generations with the addition of 50% of new alloy on the occasion of every recasting. Analysis Energy Dispersive X-ray (EDX) (Oxford Instruments) and Scanning Electon Microscop (SEM) analysis (JEOL) were used to determine thickness of metal-ceramic interface together with PC Software for quantification of visual informations (KVI POPOVAC). Results of this research introduced significant differences between thickness of metal-ceramic interface in every examined recycle generation. Recasting had negative effect on thickness of metal-ceramic interface of the examined alloys. This research showed almost linear reduction of elastic modulus up to the 12th generation of recycling. Recasting of nickel-chromium and cobalt-chromium alloys is not recommended because of reduced thickness of metal-ceramic interface of these alloys. Instead of recycling, the alloy residues should be returned to the manufacturers.

  11. Characteristics of chromium-allergic dermatitis patients prior to regulatory intervention for chromium in leather: a questionnaire study.

    Science.gov (United States)

    Bregnbak, David; Thyssen, Jacob P; Zachariae, Claus; Johansen, Jeanne D

    2014-12-01

    Chromium-tanned leather articles currently constitute the most important cause of contact allergy to chromium in Denmark. A regulation on the content of hexavalent chromium in leather was adopted in November 2013 by the EU member states. To characterize patients with chromium allergy and their disease, to serve as a baseline for future studies on the potential effect of the new regulation on chromium in leather. A questionnaire case-control study was performed on 155 dermatitis patients with positive patch test reactions to potassium dichromate and a matched control group of 621 dermatitis patients. Comparisons were made by use of a χ(2) -test and the Mann-Whitney U-test. Logistic regression analyses were used to test for associations. Sixty-six per cent of chromium-allergic patients had a positive history of contact dermatitis caused by leather exposure. They had a significantly lower quality of life (p leather articles. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Evaluation of Metal Ion Concentration in Hard Tissues of Teeth in Residents of Central Poland

    Directory of Open Access Journals (Sweden)

    Piotr Wychowanski

    2017-01-01

    Full Text Available Objectives. The aim of the study was an assessment of the content of trace elements in enamel and dentin of teeth extracted in patients residing in urban and agricultural areas of Poland. Methods. The study included 30 generally healthy patients with retained third molars. 65 samples of enamel and dentin from individuals living in urban areas and 85 samples of enamel and dentin from individuals living in agricultural areas were prepared. The content of manganese, lead, cadmium, and chromium in the studied enamel and dentin samples from retained teeth was determined by Graphite Furnace Atomic Absorption Spectrometry. In the process of statistical hypothesis testing, the level of significance was assumed at α=0.05. Results. A comparative analysis of the data showed that enamel and dentin of inhabitants of industrialized areas contain significantly higher amounts of lead and cadmium than hard tissues of teeth in residents of agricultural areas and comparable amounts of manganese and chromium. Significance. It appears that hard tissues of retained teeth may constitute valuable material for assessment of long-term environmental exposure to metal ions. The study confirms that the risk of exposure to heavy metals depends on the place of residence and environmental pollution.

  13. Plate Full of Color

    Centers for Disease Control (CDC) Podcasts

    2008-08-04

    The Eagle Books are a series of four books that are brought to life by wise animal characters - Mr. Eagle, Miss Rabbit, and Coyote - who engage Rain That Dances and his young friends in the joy of physical activity, eating healthy foods, and learning from their elders about health and diabetes prevention. Plate Full of Color teaches the value of eating a variety of colorful and healthy foods.  Created: 8/4/2008 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 8/5/2008.

  14. Chromium, CLA, and ractopamine for finishing pigs.

    Science.gov (United States)

    Marcolla, C S; Holanda, D M; Ferreira, S V; Rocha, G C; Serão, N V L; Duarte, M S; Abreu, M L T; Saraiva, A

    2017-10-01

    This study aimed to evaluate the effects of dietary chromium, CLA, and ractopamine on performance, carcass traits, and pork quality of finishing pigs slaughtered at 115 kg BW. Ninety-six crossbred barrows (initial BW = 70.21 ± 1.98 kg) were randomly assigned to 1 of 6 dietary treatments. There were 8 replicates per treatment (48 pens; 2 pigs/pen). A diet formulated according to the nutritional requirements was used as the control (CON). The other 5 diets were based on the CON and supplemented as follows: 0.4 mg/kg Cr yeast (CrY); 0.5% CLA; 0.4 mg/kg CrY and 0.5% CLA (CrY + CLA); 20 mg/kg ractopamine (RAC); 0.4 mg/kg CrY and 20 mg/kg RAC (CrY + RAC). Lysine levels on diets containing ractopamine were raised by 20% compared to CON to meet the greater requirements of pigs fed ractopamine. Pigs fed RAC and CrY + RAC were fed CON for the first 17 d, and then the respective diets for the last 28 d on trial. Data were analyzed in a model including the fixed effect of treatment (6 levels) and initial BW as a covariate for all characteristics, with the exception of carcass traits, in which final BW was used as a covariate. Least-squares means were separated using Tukey-Kramer's method. Differences were considered when probability values were lower than 0.05. Pigs fed RAC and CrY + RAC had the greatest ( 0.05) pork quality, except for color. No differences ( > 0.05) were observed for carcasses pH and temperature. The values for pigs fed RAC were greater ( = 0.01) than pigs fed other diets. Pigs fed RAC had lower ( < 0.01) values compared to pigs fed other experimental diets. Serum urea nitrogen concentration (SUN) was lower ( = 0.02) in pigs fed CrY + RAC than in pigs fed CON and RAC and similar to pigs fed the other feeding additives. In summary, it was demonstrated that, when combined, CrY and RAC increase LM area and carcass yield, and reduce SUN, suggesting that chromium could improve nutrient utilization by muscle cells in RAC-fed pigs. Additionally, the additives have

  15. Multi-scale mechanical investigation of stainless steel and cobalt-chromium stents.

    Science.gov (United States)

    Kapnisis, Konstantinos; Constantinides, Georgios; Georgiou, Harry; Cristea, Daniel; Gabor, Camelia; Munteanu, Daniel; Brott, Brigitta; Anderson, Peter; Lemons, Jack; Anayiotos, Andreas

    2014-12-01

    In-stent restenosis (ISR) remains a significant limitation despite the considerable previous clinical and investigative emphasis on the problem. Complications arising from the interaction of stent materials with the surrounding vessel wall as well as from the mechanical forces developing after implantation, play an important role in the development of ISR. To investigate the relation between mechanical factors and stent structural integrity, and to identify any structural weakness points on the geometry of commercially available Stainless Steel and Cobalt-Chromium stents, accelerated pulsatile durability tests were carried out in a simulated physiological environment. Potential spatial variations in the mechanical properties on stent struts and their role in the observed premature failures of the stent devices during operation were also examined. Fretting wear and fatigue-induced fractures were found on stent surfaces after exposure to cyclic loading similar to that arising in vivo. Nanoindentation studies performed on various locations along the stent struts have shown that the hardness of specific stent locations significantly increases after mechanical expansion. The increase in hardness was associated with a reduction of the material's ability to dissipate energy in plastic deformations, therefore an increased vulnerability to fracture and fatigue. We conclude that the locations of fatigue fractures in stent struts are controlled not only by the geometrically-driven stress concentrations developing during cyclic loading but also by the local material mechanical changes that are imparted on various parts of the stent during the deployment process. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Stress in hard metal films

    NARCIS (Netherlands)

    Janssen, G.C.A.M.; Kamminga, J.D.

    2004-01-01

    In the absence of thermal stress, tensile stress in hard metal films is caused by grain boundary shrinkage and compressive stress is caused by ion peening. It is shown that the two contributions are additive. Moreover tensile stress generated at the grain boundaries does not relax by ion

  17. Inclusive Hard Diffraction at HERA

    CERN Document Server

    Proskuryakov, Alexander

    2010-01-01

    Recent data from the H1 and ZEUS experiments on hard inclusive diffraction are discussed. Results of QCD analyses of the diffractive deep-inelastic scattering processes are reported. Predictions based on the extracted parton densities are compared to diffractive dijet measurements.

  18. Hard processes in hadronic interactions

    Energy Technology Data Exchange (ETDEWEB)

    Satz, H. [CERN, Geneva (Switzerland)]|[Universitat Bielefeld (Germany); Wang, X.N. [Lawrence Berkeley Lab., CA (United States)

    1995-07-01

    Quantum chromodynamics is today accepted as the fundamental theory of strong interactions, even though most hadronic collisions lead to final states for which quantitative QCD predictions are still lacking. It therefore seems worthwhile to take stock of where we stand today and to what extent the presently available data on hard processes in hadronic collisions can be accounted for in terms of QCD. This is one reason for this work. The second reason - and in fact its original trigger - is the search for the quark-gluon plasma in high energy nuclear collisions. The hard processes to be considered here are the production of prompt photons, Drell-Yan dileptons, open charm, quarkonium states, and hard jets. For each of these, we discuss the present theoretical understanding, compare the resulting predictions to available data, and then show what behaviour it leads to at RHIC and LHC energies. All of these processes have the structure mentioned above: they contain a hard partonic interaction, calculable perturbatively, but also the non-perturbative parton distribution within a hadron. These parton distributions, however, can be studied theoretically in terms of counting rule arguments, and they can be checked independently by measurements of the parton structure functions in deep inelastic lepton-hadron scattering. The present volume is the work of Hard Probe Collaboration, a group of theorists who are interested in the problem and were willing to dedicate a considerable amount of their time and work on it. The necessary preparation, planning and coordination of the project were carried out in two workshops of two weeks` duration each, in February 1994 at CERn in Geneva andin July 1994 at LBL in Berkeley.

  19. Neoplasms of the hard palate.

    Science.gov (United States)

    Aydil, Utku; Kızıl, Yusuf; Bakkal, Faruk Kadri; Köybaşıoğlu, Ahmet; Uslu, Sabri

    2014-03-01

    Although the most common neoplastic lesion of the oral cavity is squamous cell carcinoma (SCC), primary neoplastic lesions of the hard palate have not been systematically reviewed to date. The aim of this study was to determine the histopathologic composition and characteristics of neoplasms of the hard palate. A retrospective analysis of 66 patients with a primary neoplasm of the hard palate managed at the authors' institution from 1985 through 2012 was performed. Demographic features, malignancy rate, histopathologic characteristics and distribution, TNM staging results, metastasis patterns, and management strategies were investigated. The sample was composed of 66 patients (mean age, 45.0 yr; 57.6% men). Neoplasms were benign in 57.6% of cases and malignant in 42.4%. Epithelial neoplasms and mesenchymal neoplasms were encountered in 52 patients (78.8%) and 14 patients (21.2%), respectively. Minor salivary gland tumors (MSGTs) were the most common histopathologic group (60.6%), followed by benign mesenchymal tumors (15.2%), SCCs (12.1%), malignant melanomas (6.1%), lymphomas (3.0%), and sarcomas (3.0%). Although 75.0% of malignant epithelial neoplasms were at an advanced stage, there were no pN+ SCC or malignant MSGT cases at presentation. The most common neoplasms of the hard palate were MSGTs. SCCs were relatively rare in this series. Although three-fourths of neoplasms were at an advanced stage, neck metastasis was not a characteristic of malignant epithelial neoplasms located in the hard palate. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Plate tectonics and sedimentation

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Yasuji

    1988-05-20

    The theory of continental drift which German meteorologist, Wegener had proposed was denied by the experts at that time and disappeared from the academy. However, scholars of UK measured palaeomagnetism at several parts of the world in 1950's and from this standpoint, the continental drift theory revived. Furthermore, the conditions of the ocean beds started to be discovered due to the development of oceanographic observations in 1950's and in the end of 1960's, the principle of plate tectonics was firmly established changing totally and dramatically then conventional solid earth science based upon the substantially immovable continents and ocean floors. Consequently, the geology up to that time was obliged to be reexamined in its entire fields. This article provides the general information on the above history up to the present time, states about where the sedimentary basins which formed strata do occupy its positions on the earth, and explains the concrete relationship between the geological facts which have been revealed and plate tectonics. (16 figs, 49 refs)

  1. A Rare Terminal Dinitrogen Complex of Chromium

    Energy Technology Data Exchange (ETDEWEB)

    Mock, Michael T.; Chen, Shentan; Rousseau, Roger J.; O' Hagan, Molly J.; Dougherty, William G.; Kassel, W. S.; DuBois, Daniel L.; Bullock, R. Morris

    2011-10-12

    The reduction of dinitrogen to ammonia from N2 and H2 is currently carried out by the Haber-Bosch process, an energy intensive process that requires high pressures and high temperatures and accounts for the production of millions of tons of ammonia per year. The development of a catalytic, energy-efficient process for N2 reduction is of great interest and remains a formidable challenge. In this communication, we are reporting the preparation, characterization and computational electronic structure analysis of a rare 'Chatt-type' ((P-P)2M(N2)2, P-P = diphosphine ligand) complex of chromium, cis-[Cr(N2)2(PPh2NBn2)2] and its reactivity with CO. This complex is supported by the diphosphine ligand PPh2NBn2, containing non-coordinating pendant amine bases, to serve as proton relays. Future studies for this complex are aimed at answering fundamental questions regarding the role of proton relays in the second coordination sphere in their ability to facilitate proton movement from an external acid to metal-bound dinitrogen ligands in the challenging multi-proton/electron reduction of N2 to ammonia.

  2. Assisted green remediation of chromium pollution.

    Science.gov (United States)

    Gheju, M; Balcu, I

    2017-12-01

    The effects of application of two anions commonly found in subsurface environments, phosphate (PO4(3-)) and sulfate (SO4(2-)), on hexavalent chromium (Cr(VI)) uptake and translocation by Zea mays, were investigated using pot-culture experiments. The two anions were tested as potential agents to mobilize Cr(VI) from polluted soil (50, 75 and 100 mg kg(-1) dw) at a dose of 16.7 mmol kg(-1). Metal uptake from soil to roots and subsequent transfer to shoots was discussed in terms of bioconcentration factor (BCF) and translocation factor (TF). The overall order of BCFs and TFs which resulted from this study was: PO4(3-) > H2O > SO4(2-); in the same time, metal concentration in plants tissues decreased in the order: root > stem > leaf. The present study suggests that PO4(3-) may be used as an environmentally compatible alternative to non-biodegradable synthetic chelants, to enhance the efficiency of Cr(VI) phytoextraction with Z. mays. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Tectonics of the Easter plate

    Science.gov (United States)

    Engeln, J. F.; Stein, S.

    1984-01-01

    A new model for the Easter plate is presented in which rift propagation has resulted in the formation of a rigid plate between the propagating and dying ridges. The distribution of earthquakes, eleven new focal mechanisms, and existing bathymetric and magnetic data are used to describe the tectonics of this area. Both the Easter-Nazca and Easter-Pacific Euler poles are sufficiently close to the Easter plate to cause rapid changes in rates and directions of motion along the boundaries. The east and west boundaries are propagating and dying ridges; the southwest boundary is a slow-spreading ridge and the northern boundary is a complex zone of convergent and transform motion. The Easter plate may reflect the tectonics of rift propagation on a large scale, where rigid plate tectonics requires boundary reorientation. Simple schematic models to illustrate the general features and processes which occur at plates resulting from large-scale rift propagation are used.

  4. Hexavalent Chromium Reduction and Its Distribution in the Cell and Medium by Chromium Resistant Fusarium solani

    Directory of Open Access Journals (Sweden)

    Mousumi Sen

    2013-01-01

    Full Text Available In the present work, batch biosorption of Cr(VI was studied using the fungal strain isolated from soil. The fungal strain was characterized as Fusarium solani. The total Cr distribution in the biomass (fungus and in the media obtained from the experiment conducted at 500 mg l -1 initial Cr(VI concentration and pH 5.0. The results indicated both intracellular and extracellular accumulation and enzymatic reduction of Cr(VI and this was supported by the Transmission Electron Microscopic (TEM observation at the same Cr(VI concentration and pH value. Chromium elution from Fusarium solani containing Cr was then tried out using a number of chromium eluting reagents and a maximum Cr could be eluted using 0.5N sodium hydroxide solution without destructing the biomass structure. The total Cr was recovered by pH adjustment from both biomass and media was found to be 44% of the initial Cr(VI concentration (500 mg l-1.

  5. Increase of chromium yield by slag reduction during production of chromium steels

    Science.gov (United States)

    Bažan, J.; Socha, L.; Kurka, V.; Jonšta, P.; Sušovský, M.

    2017-02-01

    The paper is focused on the evaluation of the course of Cr2O3 reduction from slag to alloyed steel under laboratory conditions. The experiments were aimed at the evaluation of increase in the chromium content in the melt together with the studying the behaviour of Cr2O3 and the mechanism of reduction by means of three reducing agents. Anthracite, ferrosilicon and mixtures of anthracite and ferrosilicon belong among the selected reducing agents. The experimental melts were focused on the proposal of a theoretical calculation of the consumption of selected reducing agents, study of reduction under laboratory conditions at application of alloyed steel with content of chromium of 12.16 wt. %, temperatures of 1600 °C and 1650 °C, together with the change of amount of reducing agents and reduction time. The results indicated in the paper constitute basic information on the possibilities of Cr2O3 reduction from slag; they will be used for verification of results in the pilot plant and operation experiments which will simulate operating conditions in the electric arc furnace.

  6. Effect of Particle Morphology on Cold Spray Deposition of Chromium Carbide-Nickel Chromium Cermet Powders

    Science.gov (United States)

    Fernandez, Ruben; Jodoin, Bertrand

    2017-08-01

    Nickel chromium-chromium carbide coatings provide good corrosion and wear resistance at high temperatures, making them ideal for applications where a harsh environment and high temperatures are expected. Thermal spray processes are preferred as deposition technique of cermets, but the high process temperatures can lead to decarburization and reduction of the coatings properties. Cold spray uses lower temperatures preventing decarburization. Since the metallic phase remains solid, the feedstock powder morphology becomes crucial on the deposition behavior. Six commercially available powders were studied, varying in morphology and metal/ceramic ratios. The powders were categorized into 4 groups depending on their morphology. Spherical powders lead to substrate erosion due to their limited overall ductility. Porous agglomerated and sintered powders lead to severely cracked coatings. For dense agglomerated and sintered powders, the outcome depended on the initial metal/ceramic ratio: powders with 25 wt.% NiCr led to substrate erosion while 35 wt.% NiCr powders led to dense coatings. Finally, blended ceramic-metal mixtures also lead to dense coatings. All coatings obtained had lower ceramic content than the initial feedstock powders. Interrupted spray tests, combined with FEA, helped drawing conclusions on the deposition behavior to explain the obtained results.

  7. Aluminum Manganese Molten Salt Plating

    Science.gov (United States)

    2006-06-01

    cyanide waste products are generated during all stages of the cadmium plating lifecycle . The cadmium plating process generates spent plating bath and...X Check caustic line and PVC circulation piping for leaks X Verify pH at laboratory X Measure conductivity X Replace rinse...tank, which is then routed to the rinse tank. At the rinse tank, the chemical will be injected via appropriate fittings into to a PVC pipe loop which

  8. Flexible plate and foundation modelling

    OpenAIRE

    Hosking, R. J.

    2000-01-01

    In the most common mathematical model for a moving load on a continuously- supported flexible plate, the plate is assumed thin and elastic. An exception is the inclusion of viscoelasticity in the theory for the response of a floating ice plate, where the deflexion at the critical load speed corresponding to the minimum phase speed of hybrid flexural-gravity waves consequently approaches a steady state. This is in contrast to the elastic theory, where the response is predi...

  9. Use of thermogravimetry and thermodynamic calculations for specifying chromium diffusion occurring in alloys containing chromium carbides during high temperature oxidation

    Energy Technology Data Exchange (ETDEWEB)

    Berthod, Patrice, E-mail: Patrice.Berthod@univ-lorraine.fr; Conrath, Elodie

    2015-09-01

    The chromium diffusion is of great importance for the high temperature oxidation behaviour of the chromium-rich carbides-strengthened superalloys. These ones contain high chromium quantities for allowing them well resisting hot corrosion by constituting and maintaining a continuous external scale of chromia. Knowing how chromium can diffuse in such alloys is thus very useful for predicting the sustainability of their chromia-forming behaviour. Since Cr diffusion occurs through the external part of the alloy already affected by the previous steps of oxidation (decarburized subsurface) it is more judicious to specify this diffusion during the oxidation process itself. This was successfully carried out in this work in the case of a model chromia-forming nickel-based alloy containing chromium carbides, Ni(bal.)–25Cr–0.5C (in wt.%). This was done by specifying, using real-time thermogravimetry, the mass gain kinetic due to oxidation, and by combining it with the post-mortem determination of the Cr concentration profiles in subsurface. The values of D{sub Cr} thus obtained for 1000, 1050 and 1100 °C in the alloy subsurface are consistent with the values obtained in earlier works for similar alloy's chemical compositions. - Highlights: • A Ni25Cr0.50C alloy was oxidized at high temperature in a thermo-balance. • The mass gain files were analysed to specify the Cr{sub 2}O{sub 3} volatilization constant K{sub v}. • Concentration profiles were acquired to specify the chromium gradient. • The diffusion coefficient of chromium through the subsurface was deduced. • The obtained diffusion coefficient is consistent with values previously obtained.

  10. Microstructure and hardness of WC-Co particle reinforced iron matrix surface composite

    Directory of Open Access Journals (Sweden)

    Zhang Peng

    2013-11-01

    Full Text Available In this study, a high Cr cast iron surface composite material reinforced with WC-Co particles 2-6 mm in size was prepared using a pressureless sand mold infiltration casting technique. The composition, microstructure and hardness were determined by means of energy dispersive spectrometry (EDS, electron probe microanalysis (EPMA, scanning electron microscope (SEM and Rockwell hardness measurements. It is determined that the obtained composite layer is about 15 mm thick with a WC-Co particle volumetric fraction of ~38%. During solidification, interface reaction takes place between WC-Co particles and high chromium cast iron. Melting and dissolving of prefabricated particles are also found, suggesting that local Co melting and diffusion play an important role in promoting interface metallurgical bonding. The composite layer is composed of ferrite and a series of carbides, such as (Cr, W, Fe23C6, WC, W2C, M6C and M12C. The inhomogeneous hardness in the obtained composite material shows a gradient decrease from the particle reinforced metal matrix composite layer to the matrix layer. The maximum hardness of 86.3 HRA (69.5 HRC is obtained on the particle reinforced surface, strongly indicating that the composite can be used as wear resistant material.

  11. Laterally Loaded Nail-Plates

    DEFF Research Database (Denmark)

    Nielsen, Jacob; Rathkjen, Arne

    Load-displacement curves from about 200 short-term and laterally loaded nail-plate joints are analysed. The nail-plates are from Gang-Nail Systems, type GNA 20 S. The test specimens and the measuring systems are described. The tests are divided into 32 different series. The influence of the number...... of nail row, edge distance, fixed nail-plate, bending direction, unloading, and grain direction, plate and load direction on the load-displacement curves are analysed. Mean load-displacement curves from all the tests are given....

  12. Review article. Adverse hematological effects of hexavalent chromium: an overview

    Directory of Open Access Journals (Sweden)

    Ray Rina Rani

    2016-06-01

    Full Text Available Workers of tanneries, welding industries, factories manufacturing chromate containing paints are exposed to hexavalent chromium that increas¬es the risk of developing serious adverse health effects. This review elucidates the mode of action of hexavalent chromium on blood and its adverse effects. Both leukocyte and erythrocyte counts of blood sharply decreased in Swiss mice after two weeks of intraperitoneal treatment with Cr (VI, with the erythrocytes transforming into echinocytes. The hexavalent chromium in the blood is readily reduced to trivalent form and the reductive capacity of erythrocytes is much greater than that of plasma. Excess Cr (VI, not reduced in plasma, may enter erythrocytes and lymphocytes and in rodents it induces microcytic anemia. The toxic effects of chromium (VI include mitochondrial injury and DNA damage of blood cells that leads to carcinogenicity. Excess Cr (VI increases cytosolic Ca2+ activity and ATP depletion thereby inducing eryptosis. Se, vitamin C, and quercetin are assumed to have some protective effect against hexavalent chromium induced hematological disorders.

  13. Structure and magnetic properties of chromium doped cobalt molybdenum nitrides

    Energy Technology Data Exchange (ETDEWEB)

    Guskos, Niko; Żołnierkiewicz, Grzegorz; Typek, Janusz; Guskos, Aleksander [Institute of Physics, Faculty of Mechanical Engineering and Mechatronics, West Pomeranian University of Technology, Szczecin, Piastów 48, 70-311 Szczecin (Poland); Adamski, Paweł; Moszyński, Dariusz [Institute of Inorganic Chemical Technology and Environment Engineering, West Pomeranian University of Technology, Szczecin, Pułaskiego 10, 70-322 Szczecin (Poland)

    2016-09-15

    Four nanocomposites containing mixed phases of Co{sub 3}Mo{sub 3}N and Co{sub 2}Mo{sub 3}N doped with chromium have been prepared. A linear fit is found for relation between Co{sub 2}Mo{sub 3}N and chromium concentrations. The magnetization in ZFC and FC modes at different temperatures (2–300 K) and in applied magnetic fields (up to 70 kOe) have been investigated. It has been detected that many magnetic characteristics of the studied four nanocomposites correlate not with the chromium concentration but with nanocrystallite sizes. The obtained results were interpreted in terms of magnetic core-shell model of a nanoparticle involving paramagnetic core with two magnetic sublattices and a ferromagnetic shell related to chromium doping. - Highlights: • A new chromium doped mixed Co-Mn-N nanocomposites were synthesized. • Surface ferromagnetism was detected in a wide temperature range. • Core-shell model was applied to explain nanocomposites magnetism.

  14. Chromium propionate enhances adipogenic differentiation of bovine intramuscular adipocytes

    Directory of Open Access Journals (Sweden)

    Rebecca eTokach

    2015-09-01

    Full Text Available In vitro experiments were performed to determine the effects of increasing concentrations of chromium propionate on mRNA and protein abundance of different enzymes and receptors. Intramuscular and subcutaneous preadipocytes and bovine satellite cells were isolated from the longissimus muscle to determine the effect of treatment on glucose transporter type 4 (GLUT4 and peroxisome proliferator-activated receptor γ mRNA and GLUT4 protein abundance. Preadipocyte cultures were treated with differentiation media plus either sodium propionate or different concentrations of chromium propionate (CrPro for 96, 120, and 144 h before harvest. This study indicated adipogenesis of the bovine intramuscular adipocytes were more sensitive to the treatment of chromium propionate as compared to subcutaneous adipocytes. Enhancement of adenosine monophosphate-activated protein kinase and GLUT4 mRNA by CrPro treatment may enhance glucose uptake in intramuscular adipocytes. Chromium propionate decreased GLUT4 protein levels in muscle cell cultures suggesting those cells have increased efficiency of glucose uptake due to exposure to increased levels of CrPro. In contrast, each of the two adipogenic lines had opposing responses to the CrPro. It appeared that CrPro had the most stimulative effect of GLUT4 response in the intramuscular adipocytes as compared to subcutaneous adipocytes. These findings indicated opportunities to potentially augment marbling in beef cattle fed chromium propionate during the finishing phase.

  15. Low-chromium reduced-activation ferritic steels for fusion

    Energy Technology Data Exchange (ETDEWEB)

    Klueh, R.L.; Alexander, D.J.; Kenik, E.A. [Oak Ridge National Laboratory, TN (United States)

    1996-04-01

    Development of reduced-activation ferritic steels has concentrated on high-chromium (8-10 wt% Cr) steels. However, there are advantages for a low-chromium steel, and initial ORNL studies on reduced-activation steels were on compositions with 2.25 to 12% Cr. Those studies showed an Fe-2.25Cr-2W-0.25V-0.1C (2 1/4Cr-2WV) steel to have the highest strenglth of the steels studied. Although this steel had the best strength, Charpy impact properties were inferior to those of an Fe-9Cr-2W-0.25V-0.07Ta-0.1C (9Cr-2WVTa) and an Fe-2.25Cr-2W-0.1C (2 1/4Cr-2W) steel. Therefore, further development of the low-chromium Cr-W steels was required. These results indicate that it is possible to develop low-chromium reduced-activation ferritic steels that have tensile and impact properties as good or better than those of high-chromium (7-9% Cr) steels. Further improvement of properties should be possible by optimizing the composition.

  16. Anthropogenic Chromium Emissions in China from 1990 to 2009

    Science.gov (United States)

    Cheng, Hongguang; Zhou, Tan; Li, Qian; Lu, Lu; Lin, Chunye

    2014-01-01

    An inventory of chromium emission into the atmosphere and water from anthropogenic activities in China was compiled for 1990 through to 2009. We estimate that the total emission of chromium to the atmosphere is about 1.92×105t. Coal and oil combustion were the two leading sources of chromium emission to the atmosphere in China, while the contribution of them showed opposite annual growth trend. In total, nearly 1.34×104t of chromium was discharged to water, mainly from six industrial categories in 20 years. Among them, the metal fabrication industry and the leather tanning sector were the dominant sources of chromium emissions, accounting for approximately 68.0% and 20.0% of the total emissions and representing increases of15.6% and 10.3% annually, respectively. The spatial trends of Cr emissions show significant variation based on emissions from 2005 to 2009. The emission to the atmosphere was heaviest in Hebei, Shandong, Guangdong, Zhejiang and Shanxi, whose annual emissions reached more than 1000t for the high level of coal and oil consumption. In terms of emission to water, the largest contributors were Guangdong, Jiangsu, Shandong and Zhejiang, where most of the leather production and metal manufacturing occur and these four regions accounted for nearly 47.4% of the total emission to water. PMID:24505309

  17. Development of a coprecipitation system for the speciation/preconcentration of chromium in tap waters.

    Science.gov (United States)

    Karatepe, Aslihan; Korkmaz, Esra; Soylak, Mustafa; Elci, Latif

    2010-01-15

    A method for the speciation of chromium(III), chromium(VI) and determination of total chromium based on coprecipitation of chromium(III) with dysprosium hydroxide has been investigated and applied to tap water samples. Chromium(III) was quantitatively recovered by the presented method, while the recovery values for chromium(VI) was below 10%. The influences of analytical parameters including amount of dysprosium(III), pH, centrifugation speed and sample volume for the quantitative precipitation were examined. No interferic effects were observed from alkali, earth alkali and some transition metals for the analyte ions. The detection limits (k=3, N=15) were 0.65 microg/L for chromium(III) and 0.78 microg/L for chromium(VI). The validation of the presented method was checked by the analysis of certified reference materials.

  18. 77 FR 61431 - Hexavalent Chromium Standards; Extension of the Office of Management and Budget's (OMB) Approval...

    Science.gov (United States)

    2012-10-09

    ... monitoring, notifying workers of their chromium exposures, implementing medical surveillance of workers... personnel of chromium hazards and maintaining workers' exposure monitoring and medical surveillance records... other technological information collection and transmission techniques. III. Proposed Actions OSHA is...

  19. Intermittent plate tectonics?

    Science.gov (United States)

    Silver, Paul G; Behn, Mark D

    2008-01-04

    Although it is commonly assumed that subduction has operated continuously on Earth without interruption, subduction zones are routinely terminated by ocean closure and supercontinent assembly. Under certain circumstances, this could lead to a dramatic loss of subduction, globally. Closure of a Pacific-type basin, for example, would eliminate most subduction, unless this loss were compensated for by comparable subduction initiation elsewhere. Given the evidence for Pacific-type closure in Earth's past, the absence of a direct mechanism for termination/initiation compensation, and recent data supporting a minimum in subduction flux in the Mesoproterozoic, we hypothesize that dramatic reductions or temporary cessations of subduction have occurred in Earth's history. Such deviations in the continuity of plate tectonics have important consequences for Earth's thermal and continental evolution.

  20. VISAS AND GREEN PLATES

    CERN Document Server

    2000-01-01

    From 3 April 2000, all questions relating to visa requests for Switzerland, France, or Russia for a member of the personnel must be addressed to Ms. Agnita Querrou (telephone 72838, office 5-2-019, e-mail Agnita.Querrou@cern.ch).The Users' Office continues to deal with requests for letters of invitation and questions concerning visas for users in EP Division.Questions relating to removals, requests for green plates, to privileges of members of the personnel and to the importation of vehicles are still dealt with by Ms Zuzana Miller (telephone 79257, office 33-1-017, e-mail Zuzana.Muller@cern.ch) and Ms Joëlle Belleman (telephone 73962, office 33-1-019, e-mail Joelle.Belleman@cern.ch).

  1. CMS results on hard diffraction

    CERN Document Server

    INSPIRE-00107098

    2013-01-01

    In these proceedings we present CMS results on hard diffraction. Diffractive dijet production in pp collisions at $\\sqrt{s}$=7 TeV is discussed. The cross section for dijet production is presented as a function of $\\tilde{\\xi}$, representing the fractional momentum loss of the scattered proton in single-diffractive events. The observation of W and Z boson production in events with a large pseudo-rapidity gap is also presented.

  2. Plate osteosynthesis of simple forearm fractures : LCP versus DC plates

    NARCIS (Netherlands)

    Stevens, Charles Tjerk; Ten Duis, Henk Jan

    The aim of this study was to compare the time to radiological bony union of simple A-type fractures of the forearm, treated with either a locking compression plate (LCP) or a dynamic compression plate (DCP). For each fracture, the relation between the use of compression and radiological healing time

  3. Playing Moderately Hard to Get

    Directory of Open Access Journals (Sweden)

    Stephen Reysen

    2013-12-01

    Full Text Available In two studies, we examined the effect of different degrees of attraction reciprocation on ratings of attraction toward a potential romantic partner. Undergraduate college student participants imagined a potential romantic partner who reciprocated a low (reciprocating attraction one day a week, moderate (reciprocating attraction three days a week, high (reciprocating attraction five days a week, or unspecified degree of attraction (no mention of reciprocation. Participants then rated their degree of attraction toward the potential partner. The results of Study 1 provided only partial support for Brehm’s emotion intensity theory. However, after revising the high reciprocation condition vignette in Study 2, supporting Brehm’s emotion intensity theory, results show that a potential partners’ display of reciprocation of attraction acted as a deterrent to participants’ intensity of experienced attraction to the potential partner. The results support the notion that playing moderately hard to get elicits more intense feelings of attraction from potential suitors than playing too easy or too hard to get. Discussion of previous research examining playing hard to get is also re-examined through an emotion intensity theory theoretical lens.

  4. Reduction of chromium oxide from slags

    Directory of Open Access Journals (Sweden)

    Gutiérrez-Paredes, J.

    2005-12-01

    Full Text Available Experimental and theoretical work were performed to estimate the effect of slag basicity and amount of reducing agents on the reduction of chromium oxide from the slag which interacted with molten steel at 1,600 °C. The slag system contained CaO, MgO, SiO2, CaF2 and Cr2O3 together with Fe-alloys (Fe-Si and Fe-Si-Mg. The CaF2 and MgO contents in the slags were 10 mass % each; Cr2O3 was 25%. The amount of the ferroalloys ranged from 12.5 to 50 g per 100 g of slag. The (CaO+MgO/SiO2 ratio was held at 1 and 2. The Cr yield was determined using both Fe-alloys as reducing agents. Some estimations were made to determine the theoretical effect of temperature, slag basicity, (CaO+MgO/SiO2, and amount of reducing agents in the slag on the chromium recovery. The FACT (Facility for the Analysis of Chemical Thermodynamics computational package is used to determine the equilibrium between the slag and molten steel.

    En el presente trabajo se realiza un estudio teórico y experimental para determinar el efecto de la basicidad de la escoria y la cantidad de agentes reductores sobre la reducción de óxidos de cromo contenidos en la escoria, la cual está en contacto con acero líquido a 1.600 °C. La escoria se prepara con los reactivos CaO, MgO, SiO2, CaF2 y ferroaleaciones (Fe-Si y Fe-Si-Mg. Los contenidos de CaF2 y MgO en la escoria son de 10 %, cada uno, y el de Cr2O3 es 25 %. La cantidad de la ferroaleación varía de 12,5 a 50 g por cada 100 g de escoria. La relación (CaO+MgO/SiO2 tiene los valores de 1 y 2. Se determina la eficiencia de recuperación de cromo empleando los dos tipos de ferroaleaciones. Se realizaron cálculos para determinar el efecto teórico de la temperatura, la basicidad de la escoria, (CaO+MgO/SiO2, y la cantidad de agentes reductores sobre la reducci

  5. Modeling particulate removal in plate-plate and wire-plate electrostatic precipitators

    Directory of Open Access Journals (Sweden)

    S Ramechecandane

    2016-09-01

    Full Text Available The present study is concerned with the modeling of electrically charged particles in a model plate-plate and a single wire-plate electrostatic precipitator (ESP. The particle concentration distributions for both a plate-plate and a wire-plate ESP are calculated using a modified drift flux model. Numerical investigations are performed using the modified drift flux model for particle number concentration, in addition to the RNG k - ε model for the mean turbulent flow field and the Poisson equation for the electric field. The proposed model and the outlined methodology for coupling the flow field, electric field, charging kinetics and particle concentration is applied to two model precipitators that are truly representative of a wide class of commercialized ESPs. The present investigation is quite different from the earlier studies as it does not make assumptions like a homogeneous electric field or an infinite turbulent diffusivity. The electric field calculated is a strong function of position and controls the migration velocity of particles. Hence, the proposed model can be implemented in a flow solver to obtain a full-fledged solution for any kind of ESP with no limitations on the particle number concentration, as encountered in a Lagrangian approach. The effect of turbulent diffusivity on particle number concentration in a plate-plate ESP is investigated in detail and the results obtained are compared with available experimental data. Similarly, the effect of particle size/diameter and applied electric potential on the accumulative collection performance in the case of a wire-plate ESP is studied and the results obtained are compared with available numerical data. The numerical results obtained using the modified drift flux model for both the plate-plate and wire-plate ESP are in close agreement with available experimental and numerical data.

  6. Plate tectonics, damage and inheritance.

    Science.gov (United States)

    Bercovici, David; Ricard, Yanick

    2014-04-24

    The initiation of plate tectonics on Earth is a critical event in our planet's history. The time lag between the first proto-subduction (about 4 billion years ago) and global tectonics (approximately 3 billion years ago) suggests that plates and plate boundaries became widespread over a period of 1 billion years. The reason for this time lag is unknown but fundamental to understanding the origin of plate tectonics. Here we suggest that when sufficient lithospheric damage (which promotes shear localization and long-lived weak zones) combines with transient mantle flow and migrating proto-subduction, it leads to the accumulation of weak plate boundaries and eventually to fully formed tectonic plates driven by subduction alone. We simulate this process using a grain evolution and damage mechanism with a composite rheology (which is compatible with field and laboratory observations of polycrystalline rocks), coupled to an idealized model of pressure-driven lithospheric flow in which a low-pressure zone is equivalent to the suction of convective downwellings. In the simplest case, for Earth-like conditions, a few successive rotations of the driving pressure field yield relic damaged weak zones that are inherited by the lithospheric flow to form a nearly perfect plate, with passive spreading and strike-slip margins that persist and localize further, even though flow is driven only by subduction. But for hotter surface conditions, such as those on Venus, accumulation and inheritance of damage is negligible; hence only subduction zones survive and plate tectonics does not spread, which corresponds to observations. After plates have developed, continued changes in driving forces, combined with inherited damage and weak zones, promote increased tectonic complexity, such as oblique subduction, strike-slip boundaries that are subparallel to plate motion, and spalling of minor plates.

  7. Analysis of Plasticity, Fracture and Friction in Steady State Plate Cutting

    DEFF Research Database (Denmark)

    Simonsen, Bo Cerup; Wierzbicki, Tomasz

    1996-01-01

    A closed form solution to the problem of steady state wedge cutting through a ductile metal plate is presented. The considered problem is an idealization of a ship bottom raking process, i.e. a continuous cutting damage of a ship bottom by a hard knife-like rock in a grounding event. A new kinema...

  8. Why Are Drugs So Hard to Quit?

    Medline Plus

    Full Text Available ... Quitting drugs is hard because addiction is a brain disease. Your brain is like a control tower that sends out ... and choices. Addiction changes the signals in your brain and makes it hard to feel OK without ...

  9. Hardness of Potable Water in Southwestern Skane

    OpenAIRE

    Kos, Z.

    1982-01-01

    This paper is concerned with water hardness in the municipal water supply systems. After a general overview of the health aspects of water hardness, this issue is discussed in the specific context of Southwestern Skane, Sweden.

  10. Toxic effects of chromium on Schistosoma haematobium miracidia

    Energy Technology Data Exchange (ETDEWEB)

    Wolmarans, C.T.; Yssel, E.; Hamilton-Attwell, V.L.

    1988-12-01

    Various heavy metals have recently been evaluated as molluscicides for freshwater snails, which act as intermediate hosts of trematode parasites of medical or veterinary importance. Very little information, however, is available on heavy metals that may be suitable to eliminate the parasites as such. Suitable compounds should also inhibit the penetration ability of parasites as well as stunt the development of those who do not penetrate their hosts. In the light of these requirements, the present study evaluated the effect of chromium on the miracidia of Schistosoma haematobium, which causes urinary bilharzia. Attention was mainly focused on (1) the chromium concentration which resulted in 100% mortality (2) the effect of chromium on the external and internal morphology of the miracidia, and (3) the ability of the miracidia to form sporocytes in vitro and in vivo and to penetrate their intermediate host snail, Bulinus africanus.

  11. The nature of temper brittleness of high-chromium ferrite

    Energy Technology Data Exchange (ETDEWEB)

    Sarrak, V.I.; Suvorova, S.O.; Golovin, I.S.; Mishin, V.M.; Kislyuk, I.V. [Central Scientific-Research Institute for Ferrous Metallurgy, Moscow (Russian Federation)

    1995-03-01

    The reasons for development of {open_quotes}475{degrees}C brittleness{close_quotes} of high-chromium ferritic steels are considered from the standpoint of fracture mechanics. It is shown that the general rise in the curve of temperature-dependent local flow stress has the decisive influence on the position of the ductile-to-brittle transformation temperature and the increase in it as the result of a hold at temperatures of development of brittleness. The established effect is related to the change in the parameters determining dislocation mobility, that is, the activation energy of dislocation movement in high-chromium ferrite and the resistance to microplastic deformation, both caused by processes of separation into layers of high-chromium ferrite and decomposition of the interstitial solid solution.

  12. Bioabsorption of chromium from retan chrome liquor by cyanobacteria.

    Science.gov (United States)

    Pandi, M; Shashirekha, V; Swamy, Mahadeswara

    2009-01-01

    The bioaccumulation of chromium from retan chrome liquor by Spirulina fusiformis was investigated under laboratory as well as field conditions. At the optimal conditions, metal ion uptake increased with initial metal ion concentration up to 300mg/l. The effect on various physico-chemical parameters like total solids (TS), total dissolved solids (TDS), total suspended solids (TSS), chlorides, sulphates, phenols, biochemical oxygen demand (BOD) and chemical oxygen demand (COD) and biochemical studies related to biomass, chlorophyll-a and protein were also carried out. The present study indicates that S. fusiformis is very effective in removal of chromium (93-99%) besides removing other toxicants from retan chrome liquor. The sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE) and FTIR studies indicate the interaction/complexation between Cr and alga. The mechanism involved in bioaccumulation of chromium is also discussed. The process when upgraded can be applied for detoxification of tannery effluents.

  13. A study of the process of desorption of hexavalent chromium

    Directory of Open Access Journals (Sweden)

    W.B. Amorim

    2003-09-01

    Full Text Available In this work the process of desorption of hexavalent chromium, a toxic metal ion, from the marine algae Sargassum sp, following biosorption experiments 2³ factorial design was studied. A technique was applied to three eluents: HCl, H2SO4 and EDTA. Three factors of importance were evaluated: concentration of eluent, the ratio between mass of biosorbent and volume of eluent (S/L and process time. A statistical analysis of the experimental results showed that the three variables evaluated are significant for all three eluents. The models for chromium desorption were validated, as the results agreed well with the observed values. Through use of the response surface methodology, a factorial design based optimization technique; it was possible to identify the most suitable eluent and the interval of values for the process variables that resulted in the most significant desorption of chromium, which is relevant information for work aiming at process optimization.

  14. Chromium Resistant Bacteria: Impact on Plant Growth in Soil Microcosm

    Directory of Open Access Journals (Sweden)

    Sayel Hanane

    2014-07-01

    Full Text Available Three chromium resistant bacterial strains, Pseudomonas fluorescens PF28, Enterobacter amnigenus EA31 and Enterococcus gallinarum S34 isolated from tannery waste contaminated soil were used in this study. All strains could resist a high concentration of K2Cr2O7 that is up to 300 mg/L. The effect of these strains on clover plants (Trifolium campestre in the presence of two chromium salts CrCl3 and K2Cr2O7 was studied in soil microcosm. Application of chromium salts adversely affected seed germination, root and shoot length. Bacterial inoculation improved the growth parameters under chromate stress when compared with non inoculated respective controls. There was observed more than 50% reduction of Cr(VI in inoculated soil microcosms, as compared to the uninoculated soil under the same conditions. The results obtained in this study are significant for the bioremediation of chromate pollution.

  15. Studies of removal of chromium by model constructed wetland

    Directory of Open Access Journals (Sweden)

    C. Mant

    2005-09-01

    Full Text Available Chromium is a pollutant present in tannery wastewater, its removal is necessary for protection of the environment. Penisetum purpureum, Brancharia decumbens and Phragmites australis were grown hydroponically in experimental gravel beds to determine their potential for the phytoremediation of solutions containing 10 and 20 mg Cr dm-3. These concentrations, similar to tannery wastewater after initial physico-chemical treatment were used with the aim of developing an economic secondary treatment to protect the environment. All the systems achieved removal efficiencies of 97 - 99.6% within 24 hours. P. purpureum and B. decumbens removed 78.1% and 68.5% respectively within the first hour. Both P. purpureum and B. decumbens were tolerant of the concentrations of chromium applied, but P. purpureum showed the greatest potential because its faster growth and larger biomass achieved a much greater chromium removal over the whole length of time of the experiment.

  16. Monitoring of chromium species and 11 selected metals in emission and immission of airborne environment

    NARCIS (Netherlands)

    Krystek, Petra; Ritsema, Rob

    2007-01-01

    Monitoring of chromium species as hexavalent chromium (Cr(VI)) and the determination of the total chromium concentration as well as the concentration of 11 selected metals (Al, Ca, Cd, Co, Cu, Fe, Mn, Ni, Pb, Sb, Zn) in industrial emission of a foundry and immission studies of the nearby airborne

  17. Enhancement of the acute phase response to lipopolysaccharide (LPS) challenge in steers supplemented with chromium

    Science.gov (United States)

    The study examined the effect of chromium supplementation on the response of steers to an LPS challenge. Twenty steers received a premix that added 0 (control) or 0.2 mg/kg of chromium (KemTRACE®brandChromiumProprionate 0.04%, Kemin Industries) to the total diet on a dry matter basis for 55 d. Steer...

  18. 21 CFR 73.3110a - Chromium-cobalt-aluminum oxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Chromium-cobalt-aluminum oxide. 73.3110a Section... LISTING OF COLOR ADDITIVES EXEMPT FROM CERTIFICATION Medical Devices § 73.3110a Chromium-cobalt-aluminum oxide. (a) Identity. The color additive chromium-cobalt-aluminum oxide (Pigment Blue 36) (CAS Reg. No...

  19. Chromium supplementation alters the glucose and lipid metabolism of feedlot cattle during the receiving period

    Science.gov (United States)

    Crossbreed steers (n = 20; 235 ± 4 kg) were fed 53 d during a receiving period to determine if supplementing chromium (Cr; KemTRACE®brand Chromium Propionate 0.04%, Kemin Industries) would alter the glucose or lipid metabolism of newly received cattle. Chromium premixes were supplemented to add 0 (C...

  20. 40 CFR 721.2097 - Azo chromium complex dyestuff preparation (generic name).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Azo chromium complex dyestuff... New Uses for Specific Chemical Substances § 721.2097 Azo chromium complex dyestuff preparation... substance identified generically as an azo chromium complex dyestuff preparation (PMN P-95-240) is subject...

  1. 75 FR 18041 - Defense Federal Acquisition Regulation Supplement; Minimizing Use of Hexavalent Chromium (DFARS...

    Science.gov (United States)

    2010-04-08

    ... Supplement; Minimizing Use of Hexavalent Chromium (DFARS Case 2009-D004) AGENCY: Defense Acquisition... requirements for minimizing the use of hexavalent chromium in defense weapon systems, subsystems, components, and other items. The proposed rule prohibits the delivery of items containing hexavalent chromium...

  2. Chromium supplementation alters both glucose and lipid metabolism in feedlot cattle during the receiving period

    Science.gov (United States)

    Crossbred steers (n = 20; 235 +/- 4 kg) were fed 53 days during a receiving period to determine if supplementing chromium (Cr; KemTRACE®brandChromium Propionate 0.04%, Kemin Industries) would alter the glucose or lipid metabolism of newly received cattle. Chromium premixes were supplemented to add 0...

  3. Evaluation of flexural bond strength of porcelain to used nickel-chromium alloy in various percentages

    Directory of Open Access Journals (Sweden)

    VNV Madhav

    2012-01-01

    Fresh nickel-chromium alloy shows the greatest porcelain adherence.There is no significant change in bond strength of ceramic to alloy with up to 75% of used nickel-chromium alloy.At least 25%- of new alloy should be added when recycled nickel-chromium alloy is being used for metal ceramic restorations.

  4. The Kinetics of the Silver(i)-induced Oxidation of Chromium(iii) by ...

    African Journals Online (AJOL)

    Chromium(III) and chromium(VI) compounds play an important role in natural oxidation processes in terrestrial and atmospheric water. During the oxidation of SO2, peroxodisulphate is formed as an intermediate. In acidic and neutral solutions, peroxodisulphate oxidizes chromium(III) very slowly. This reaction rate is ...

  5. [Metallurgical differentiation of cobalt-chromium alloys for implants].

    Science.gov (United States)

    Holzwarth, U; Thomas, P; Kachler, W; Göske, J; Schuh, A

    2005-10-01

    Cobalt Chromium alloys are used in cemented total hip or knee arthroplasty as well as in metal-on-metal bearings in total hip arthroplasty. An increasing number of publications report about (allergic) reactions to wear particles of Cobalt Chromium alloys. Reactions to nickel are more frequent in comparison to Cobalt or Chromium particles. It is well known that different kinds of Cobalt Chromium alloys contain different amounts of alloying elements; nevertheless. The aim of the current work was to compare the different Cobalt Chromium alloys according to ASTM F or ISO standards in respect to the different alloying elements. Co28Cr6Mo casting alloys according to ASTM F 75 or ISO 5832-4 as well as forging alloy types according to ASTM F 799 and ISO 5832 such as Co20Cr15W10Ni, Co35Ni20Cr, Fe40Co20Cr10Ni, Co20Cr20Ni, and Co28Cr6Mo were analyzed in respect to their element content of Co, Cr, Ni, Mo, Fe, W, and Mn. In 1935 the Cobalt based alloy "Vitallium" Co30Cr5Mo basically used in the aircraft industry was introduced into medicine. The chemical composition of this alloy based on Cobalt showed 30 wt.% Chromium and 5 wt.% Molybdenum. The differentiation using alloy names showed no Nickel information in single alloy names. The information given about different alloys can lead to an unprecise evaluation of histopathological findings in respect to alloys or alloying constituents. Therefore, implant manufacturers should give the exact information about the alloys used and adhere to European law, Euronorm 93/42/EWG.

  6. Flexural waves on narrow plates.

    Science.gov (United States)

    Norris, Andrew N

    2003-05-01

    Flexural wave speeds on beams or plates depend upon the bending stiffnesses which differ by the well-known factor (1 - nu2). A quantitative analysis of a plate of finite lateral width displays the plate-to-beam transition, and permits asymptotic analysis that shows the leading order dependence on the width. Orthotropic plates are analyzed using both the Kirchhoff and Kirchhoff-Rayleigh theories, and isotropic plates are considered for Mindlin's theory with and without rotational inertia. A frequency-dependent Young's modulus for beams or strips of finite width is suggested, although the form of the correction to the modulus is not unique and depends on the theory used. The sign of the correction for the Kirchhoff theory is opposite to that for the Mindlin theory. These results indicate that the different plate and beam theories can produce quite distinct behavior. This divergence in predictions is further illustrated by comparison of the speeds for antisymmetric flexural, or torsional, modes on narrow plates. The four classical theories predict limiting wave speeds as the plate width vanishes, but the values are different in each case. The deviations can be understood in terms of torsional waves and how each theory succeeds, or fails, in approximating the effect of torsion. Dispersion equations are also derived, some for the first time, for the flexural edge wave in each of the four "engineering" theories.

  7. MyPlate Food Guide

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español MyPlate Food Guide KidsHealth / For Teens / MyPlate Food Guide What's ... and other sugary drinks. Avoid large portions . Five Food Groups Different food groups have different nutrients and ...

  8. Micro-channel plate detector

    Science.gov (United States)

    Elam, Jeffrey W.; Lee, Seon W.; Wang, Hsien -Hau; Pellin, Michael J.; Byrum, Karen; Frisch, Henry J.

    2015-09-22

    A method and system for providing a micro-channel plate detector. An anodized aluminum oxide membrane is provided and includes a plurality of nanopores which have an Al coating and a thin layer of an emissive oxide material responsive to incident radiation, thereby providing a plurality of radiation sensitive channels for the micro-channel plate detector.

  9. Aseptic laboratory techniques: plating methods.

    Science.gov (United States)

    Sanders, Erin R

    2012-05-11

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: Perform plating procedures without contaminating media. Isolate single bacterial colonies by the streak-plating

  10. Contact Allergy To Hard Contact Lens

    Directory of Open Access Journals (Sweden)

    J S Pasricha

    1985-01-01

    Full Text Available Three patients developed recurrent irritation, redness and watery discharge from their eyes after using hard contact lens. Patch tests were positive with the material of the hard contact lens and negative with teepol, sodium lauryl sulphate and material of the soft contact lens. All the three patients became alright after they stopped,using hard contact lens.

  11. 7 CFR 201.30 - Hard seed.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Hard seed. 201.30 Section 201.30 Agriculture..., Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) FEDERAL SEED ACT FEDERAL SEED ACT REGULATIONS Labeling Vegetable Seeds § 201.30 Hard seed. The label shall show the percentage of hard seed, if...

  12. 7 CFR 201.21 - Hard seed.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Hard seed. 201.21 Section 201.21 Agriculture..., Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) FEDERAL SEED ACT FEDERAL SEED ACT REGULATIONS Labeling Agricultural Seeds § 201.21 Hard seed. The label shall show the percentage of hard seed...

  13. Systematic hardness measurements on single crystals and ...

    Indian Academy of Sciences (India)

    Vickers and knoop hardness measurements were carried out on CsBr and CsI single crystals. Polycrystalline blanks of CsCl, CsBr and CsI were prepared by melting and characterized by X-ray diffraction. Vickers hardness measurements were carried out on these blanks. The hardness values were correlated with the lattice ...

  14. Systematic hardness studies on lithium niobate crystals

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 23; Issue 2. Systematic hardness studies on lithium niobate crystals ... In view of discrepancies in the available information on the hardness of lithium niobate, a systematic study of the hardness has been carried out. Measurements have been made on two pure lithium ...

  15. 7 CFR 201.57 - Hard seeds.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Hard seeds. 201.57 Section 201.57 Agriculture..., Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) FEDERAL SEED ACT FEDERAL SEED ACT REGULATIONS Germination Tests in the Administration of the Act § 201.57 Hard seeds. Seeds which remain hard at...

  16. Systematic hardness studies on lithium niobate crystals

    Indian Academy of Sciences (India)

    Unknown

    1975) made Knoop hardness ... mentioned that Knoop and Vickers hardness values generally agree to within 5% (Mott 1956). Brown et al ... In the present communication, we report a detailed study of the load-dependence of hardness on two ...

  17. Broadband infrared absorbers with stacked double chromium ring resonators

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Huixu; Stan, Liliana; Czaplewski, David A.; Gao, Jie; Yang, Xiaodong

    2017-01-01

    A broadband absorber in the infrared wavelength range from 1 μm up to 5 μm is designed and demonstrated with stacked double chromium ring resonators on a reflective chromium mirror. The near-perfect broadband absorption is realized by combining the multilayer impedance match in the short wavelength range and the double plasmonic resonances in the long wavelength range, which is illustrated with an equivalent circuit model for the impedance analysis. The broadband absorber is proved to be angle-insensitive and polarization-independent due to the geometrical symmetry. The thermal analysis for heat generation and temperature distributions inside the absorber structure is also investigated.

  18. A review of chromium, molybdenum, and tungsten alloys

    Science.gov (United States)

    Klopp, W. D.

    1975-01-01

    The mechanical properties of chromium, molybdenum, and tungsten alloys are reviewed with particular emphasis on high-temperature strength and low-temperature ductility. Precipitate strengthening is highly effective at 0.4 to 0.8 times the melting temperature in these metals, with HfC being most effective in tungsten and molybdenum, and Ta(B,C) most effective in chromium. Low-temperature ductility can be improved by alloying to promote rhenium ductilizing or solution softening. The low-temperature mechanical properties of these alloys appear related to electronic interactions rather than to the usual metallurgical considerations.

  19. Use of chitosan for chromium removal from exhausted tanning baths.

    Science.gov (United States)

    Cesaro, Raffaele; Fabbricino, Massimiliano; Lanzetta, Rosa; Mancino, Anna; Naviglio, Biagio; Parrilli, Michelangelo; Sartorio, Roberto; Tomaselli, Michele; Tortora, Gelsomina

    2008-01-01

    A novel approach, based on chitosan heavy-metal sequestrating ability, is proposed for chromium(III) removal from spent tanning liquor. Experimental results, obtained at lab-scale using real wastewater, are presented and discussed. Resulting efficiencies are extremely high, and strongly dependent on chitosan dose and pH value. Comparative analyses with other polysaccharides is also carried out showing that amine groups are more efficient than carboxyl and sulphate ones. Chromium recovery from sorption complexes and chitosan regeneration is finally proposed to optimize the whole process. (c) IWA Publishing 2008.

  20. Hot corrosion resistance of nickel-chromium-aluminum alloys

    Science.gov (United States)

    Santoro, G. J.; Barret, C. A.

    1977-01-01

    The hot corrosion resistance of nickel-chromium-aluminum alloys was examined by cyclically oxidizing sodium sulfate-coated specimens in still air at 900, 1000, and 1100 C. The compositions tested were within the ternary region: Ni, Ni-50 at.% Cr, and Ni-50 at.% Al. At each temperature the corrosion data were statistically fitted to a third order regression equation as a function of chromium and aluminum contents. From these equations corrosion isopleths were prepared. Compositional regions with the best hot corrosion resistance were identified.

  1. Primary and secondary crystallization of modified hypoeutectic chromium cast iron

    Directory of Open Access Journals (Sweden)

    A. Studnicki

    2010-04-01

    Full Text Available The paper presents investigations of crystallization of modified hypoeutectic wear resistant chromium cast iron which contains carbon about 2% and chromium on three levels (12%, 18% and 25%. Three substances were applied to the modification ( boron carbide (B4C, ferroniobium (FeNb and mixture of ferroniobium and mischmetal (RE. The investigations of crystallization were conducted the DTA method in DTA-C and DTA-Is testers. The influence on the course of the process of primary and secondary crystallization was observed.

  2. Surface and Microstructural Failures of PET-Coated ECCS Plates by Salmon-Polymer Interaction

    Directory of Open Access Journals (Sweden)

    Ernesto Zumelzu

    2016-03-01

    Full Text Available The new types of knowledge-intensive, multilayer containers consist of steel plates protected against corrosion by nanometric electrolytic chromium (Cr0 and chromium oxide (Cr2O3 layers chemically bonded to polyethylene terephthalate (PET polymer coating to preserve food. It was observed that after emptying the cans, the salmon adhered to the polymer coating, changing its color, and that this adhesion increased with longer storage times. This work was aimed at determining the product-container interactions and their characterization by X-ray diffraction (XRD, confocal Raman and micro-Raman imaging and scanning electron microscopy (SEM analysis. The zones of adhesion showed surface changes, variations in crystallinity and microstructural degradation of the PET coating. In addition, localized damages altering the functional properties of the multilayer system were observed as microcracking in the chromium layers that protect the steel. The degradation undergone was evaluated and characterized at a surface and microstructural level to establish the failure mechanisms, which were mainly associated with the activity of the adhered muscle and its biochemical components. Finally, a recommendation is done to preserve the useful life and functionality of cans for the preservation and efficient use of resources with an impact on recycling and environmental conservancy.

  3. Reaction diffusion in the nickel-chromium-aluminum and cobalt-chromium-aluminum systems

    Science.gov (United States)

    Levine, S. R.

    1977-01-01

    The effects of MCrAl coating-substrate interdiffusion on oxidation life and the general mutliphase, multicomponent diffusion problem were examined. Semi-infinite diffusion couples that had sources representing coatings and sinks representing gas turbine alloys were annealed at 1,000, 1,095, 1,150, or 1,205 C for as long as 500 hours. The source and sink aluminum and chromium contents and the base metal (cobalt or nickel) determined the parabolic diffusion rate constants of the couples and predicted finite coating lives. The beta source strength concept provided a method (1) for correlating beta recession rate constants with composition; (2) for determining reliable average total, diffusion, and constitutional activation energies; and (3) for calculating interdiffusion coefficients.

  4. Synthesis of chromium-containing pigments from chromium recovered from leather waste.

    Science.gov (United States)

    Berry, Frank J; Costantini, Nicola; Smart, Lesley E

    2002-01-01

    Cobalt-chromite green and chrome-tin pink pigments have been prepared from chromium extracted from leather shavings produced as a waste product of the leather-tanning industry. The alkaline agent (NaOH, CaO, MgO, NH4OH) used in the extraction process influences the nature of the final product. The effect of the NH4OH:CaO ratio on the final product in the case of cobalt-chromite green was examined. The pigments obtained were characterized by FT-IR and X-ray diffraction (XRD). Colour measurements were compared with those recorded from materials prepared from pure Cr2O3. The leaching of Cr(VI) from the materials was examined by UV spectroscopy.

  5. Fertilizers and Mixed Crop Cultivation of Chromium Tolerant and Sensitive Plants under Chromium Toxicity

    Directory of Open Access Journals (Sweden)

    B. Dheeba

    2015-01-01

    Full Text Available Zea mays (maize and Vigna radiata (green gram are found to be the chromium (Cr tolerant and sensitive plants, respectively. In the present paper, we investigate the reduction of the toxicity of Cr in the sensitive plants by the mixed crop cultivation in the field using various amendments. Further, the potassium dichromate was used as the source of hexavalent Cr. The results indicated that Cr adversely affects both the growth and yield of plants. The soil properties vary with Cr and different fertilizer amendments and the yield of both plants were affected by Cr. We conclude that metal accumulation of seeds of green gram was higher than corn and the application of single fertilizer either farm yard manure (FYM or nitrogen, phosphorous, and potassium (NPK enhances the growth and yield of both the tolerant and sensitive plants in the mixed crop cultivations.

  6. An Experimental Evaluation of Electron Beam Welded Thixoformed 7075 Aluminum Alloy Plate Material

    Directory of Open Access Journals (Sweden)

    Ava Azadi Chegeni

    2017-12-01

    Full Text Available Two plates of thixoformed 7075 aluminum alloy were joined using Electron Beam Welding (EBW. A post-welding-heat treatment (PWHT was performed within the semi-solid temperature range of this alloy at three temperatures, 610, 617 and 628 °C, for 3 min. The microstructural evolution and mechanical properties of EB welded plates, as well as the heat-treated specimens, were investigated in the Base Metal (BM, Heat Affected Zone (HAZ, and Fusion Zone (FZ, using optical microscopy, Scanning Electron Microscopy (SEM, EDX (Energy Dispersive X-ray Analysis, and Vickers hardness test. Results indicated that after EBW, the grain size substantially decreased from 67 µm in both BM and HAZ to 7 µm in the FZ, and a hardness increment was observed in the FZ as compared to the BM and HAZ. Furthermore, the PWHT led to grain coarsening throughout the material, along with a further increase in hardness in the FZ.

  7. Plant Line Trial Evaluation of Viable Non-Chromium Passivation Systems for Electrolytin Tinplate, ETP (TRP 9911)

    Energy Technology Data Exchange (ETDEWEB)

    John A. Sinsel

    2003-06-30

    Plant trial evaluations have been completed for two zirconium-based, non-chromium passivation systems previously identified as possible alternatives to cathodic dichromate (CDC) passivation for electrolytic tinplate (ETP). These trials were done on a commercial electrolytic tin plating line at Weirton Steel and extensive evaluations of the materials resulting from these trials have been completed. All this was accomplished as a collaborative effort under the AISI Technology Roadmap Program and was executed by seven North American Tin Mill Products producers [Bethlehem Steel (now acquired by International Steel Group (ISG)), Dofasco Inc., National Steel (now acquired by U.S. Steel), U.S. Steel, USS-Posco, Weirton Steel, and Wheeling-Pittsburgh Steel] with funding partially from the Department of Energy (DOE) and partially on an equal cost sharing basis among project participants. The initial phases of this project involved optimization of application procedures for the non-chromium systems in the laboratories at Bethlehem Steel and Betz Dearborn followed by extensive testing with various lacquer formulations and food simulants in the laboratories at Valspar and PPG. Work was also completed at Dofasco and Weirton Steel to develop methods to prevent precipitation of insoluble solids as a function of time from the zirconate system. The results of this testing indicated that sulfide staining characteristics for the non-chromium passivation systems could be minimized but not totally eliminated and neither system was found to perform quite as good, in this respect, as the standard CDC system. As for the stability of zirconate treatment, a method was developed to stabilize this system for a sufficient period of time to conduct plant trial evaluations but, working with a major supplier of zirconium orthosulfate, a method for long term stabilization is still under development.

  8. Indonesian Landforms and Plate Tectonics

    Directory of Open Access Journals (Sweden)

    Herman Th. Verstappen

    2014-06-01

    Full Text Available DOI: 10.17014/ijog.v5i3.103The horizontal configuration and vertical dimension of the landforms occurring in the tectonically unstable parts of Indonesia were resulted in the first place from plate tectonics. Most of them date from the Quaternary and endogenous forces are ongoing. Three major plates – the northward moving Indo-Australian Plate, the south-eastward moving SE-Asian Plate and the westward moving Pacific Plate - meet at a plate triple-junction situated in the south of New Guinea’s Bird’s Head. The narrow North-Moluccan plate is interposed between the Asia and Pacific. It tapers out northward in the Philippine Mobile Belt and is gradually disappearing. The greatest relief amplitudes occur near the plate boundaries: deep ocean trenches are associated with subduction zones and mountain ranges with collision belts. The landforms of the more stable areas of the plates date back to a more remote past and, where emerged, have a more subdued relief that is in the first place related to the resistance of the rocks to humid tropical weathering Rising mountain ranges and emerging island arcs are subjected to rapid humid-tropical river erosions and mass movements. The erosion products accumulate in adjacent sedimentary basins where their increasing weight causes subsidence by gravity and isostatic compensations. Living and raised coral reefs, volcanoes, and fault scarps are important geomorphic indicators of active plate tectonics. Compartmental faults may strongly affect island arcs stretching perpendicular to the plate movement. This is the case on Java. Transcurrent faults and related pull-apart basins are a leading factor where plates meet at an angle, such as on Sumatra. The most complicated situation exists near the triple-junction and in the Moluccas. Modern research methods, such as GPS measurements of plate movements and absolute dating of volcanic outbursts and raised coral reefs are important tools. The mega-landforms resulting

  9. Radiation Hardness Assurance (RHA) Guideline

    Science.gov (United States)

    Campola, Michael J.

    2016-01-01

    Radiation Hardness Assurance (RHA) consists of all activities undertaken to ensure that the electronics and materials of a space system perform to their design specifications after exposure to the mission space environment. The subset of interests for NEPP and the REAG, are EEE parts. It is important to register that all of these undertakings are in a feedback loop and require constant iteration and updating throughout the mission life. More detail can be found in the reference materials on applicable test data for usage on parts.

  10. Carbon Equivalent and Maximum Hardness

    OpenAIRE

    Haruyoshi, Suzuki; Head Office, Nippon Steel Corporation

    1984-01-01

    The accuracy of formulae for estimating the maximum hardness values of the HAZ from chemical composition and cooling time for welds in high strength steel is discussed and a new formula. NSC-S, is proposed which uses only C%, Pcm% and cooling time for the purpose of satisfactory accuracy. IIW CE and Ito-Bessyo Pcm carbon equivalent alone are not satisfactory in establishing Hmax values. The former is good only for slow cooling, t8/5 longer than 10 seconds, while the latter is good only for fa...

  11. Hard Identity and Soft Identity

    Directory of Open Access Journals (Sweden)

    Hassan Rachik

    2006-04-01

    Full Text Available Often collective identities are classified depending on their contents and rarely depending on their forms. Differentiation between soft identity and hard identity is applied to diverse collective identities: religious, political, national, tribal ones, etc. This classification is made following the principal dimensions of collective identities: type of classification (univocal and exclusive or relative and contextual, the absence or presence of conflictsof loyalty, selective or totalitarian, objective or subjective conception, among others. The different characteristics analysed contribute to outlining an increasingly frequent type of identity: the authoritarian identity.

  12. Experimental studies on improving the performance of electrochemical machining of high carbon, high chromium die steel using jet patterns

    Directory of Open Access Journals (Sweden)

    V. Sathiyamoorthy

    2014-03-01

    Full Text Available Electrochemical machining (ECM is a non-traditional process used mainly to cut hard or difficult-to-cut metals, where the application of a more traditional process is not convenient. Stiff market competition and ever-growing demand for better, durable and reliable products has brought about a material revolution, which has greatly expanded the families of difficult-to-machine materials namely highcarbon,high-chromium die steel; stainless steel and superalloys. This investigation attempts to analyze the effect of electrolyte distribution on material removal rate (MRR and surface roughness (SR on electrochemical machining of high-carbon, high-chromium die steel using NaCl aqueous solution. Three electrolyte jet patterns namely straight jet in circular, inclined jet in circular and straight jet in spiral were used for this experimentation. The results reveal that electrolyte distribution significantly improves the performance of ECM and the straight jet in spiral pattern performs satisfactorily in obtaining better MRR and surface roughness.

  13. Reactor target from metal chromium for "pure" high-intensive artificial neutrino source

    Science.gov (United States)

    Gavrin, V. N.; Kozlova, Yu. P.; Veretenkin, E. P.; Logachev, A. V.; Logacheva, A. I.; Lednev, I. S.; Okunkova, A. A.

    2017-01-01

    The paper presents the first results of development of manufacturing technology of metallic chromium targets from highly enriched isotope 50Cr for irradiation in a high flux nuclear reactor to obtain a compact high intensity neutrino source with low content of radionuclide impurities and minimum losses of enriched isotope. The main technological stages are the hydrolysis of chromyl fluoride, the electrochemical reduction of metallic chromium, the hot isostatic pressing of chromium powder and the electrical discharge machining of chromium bars. The technological stages of hot isostatic pressing of chromium powder and of electrical discharge machining of Cr rods have been tested.

  14. The oxidation and reduction of chromium of stainless steels in an eletric arc furnace

    Directory of Open Access Journals (Sweden)

    B. Arh

    2011-07-01

    Full Text Available The oxidation of chromium during the elaboration of stainless steels occurs with oxygen in solution blown inthe melt and with oxides in the slag. A higher content of silicon in the furnace charge decreases the extent of oxidation of chromium, however, the efficient reduction of chromium from the slag is of essential importance for a minimal loss of chromium. In this survey, the theory of the oxidation of chromium, its reduction from the slag and the conditions for the formation of foaming slag are discussed.

  15. 21 CFR 176.160 - Chromium (Cr III) complex of N-ethyl-N-heptadecylfluoro-octane sulfonyl glycine.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Chromium (Cr III) complex of N-ethyl-N... § 176.160 Chromium (Cr III) complex of N-ethyl-N-heptadecylfluoro-octane sulfonyl glycine. The chromium... by weight of the chromium (Cr III) complex of heptadecylfluoro-octane sulfonic acid may be safely...

  16. Platonic scattering cancellation for bending waves in a thin plate

    KAUST Repository

    Farhat, Mohamed

    2014-04-10

    We propose an ultra-thin elastic cloak to control the scattering of bending waves in isotropic heterogeneous thin plates. The cloak design makes use of the scattering cancellation technique applied, for the first time, to the biharmonic operator describing the propagation of bending waves in thin plates. We first analyze scattering from hard and soft cylindrical objects in the quasistatic limit, then we prove that the scattering of bending waves from an object in the near and far-field regions can be suppressed significantly by covering it with a suitably designed coating. Beyond camouflaging, these findings may have potential applications in protection of buildings from earthquakes and isolating structures from vibrations in the motor vehicle industry.

  17. Characterization of surface chromium and molybdenum alloying on gray cast iron obtained by the plasma-transferred arc technique

    Energy Technology Data Exchange (ETDEWEB)

    Giordano, L.; Tiziani, A.; Zambon, A. (DIMEG, Univ. Padua (Italy)); Antolotti, N. (FLAMETAL Spa, Parma (Italy))

    1991-07-07

    Chromium and molybdenum alloying of gray cast iron to obtain surface wear-resistance coatings by means of the plasma-transferred arc (PTA) technique has been studied. Disk-shaped specimens for mounting on a pin-on-disk wear-testing machine were obtained. The disks were then heat treated to develop different hardness values and wear resistance behavior. Besides an untreated sample, samples treated at 900degC for 10 min, at 1000degC for 10 min and at 1100degC for 20 min were studied. The specimens showed defect-free coatings with the complete absence of porosity, cracks and segregation. The obtained coatings were stable as regards thermal cycles, which could affect workpieces subject to wear conditions. Microhardness profile, optical microscopy and scanning electron microscopy observations were performed together with qualitative and quantitative energy-dispersive spectroscopy microanalysis, as well as X-ray diffraction on the extracted carbides. (orig.).

  18. The chromium accumulation and its physiological effects in juvenile rockfish, Sebastes schlegelii, exposed to different levels of dietary chromium (Cr(6+)) concentrations.

    Science.gov (United States)

    Kim, Jun-Hwan; Kang, Ju-Chan

    2016-01-01

    Juvenile rockfish (mean length 13.7±1.7 cm, and mean weight 55.6±4.8 g) were exposed for 4 weeks with the different levels of dietary chromium (Cr(6+)) at 0, 30, 60, 120 and 240 mg/kg. The profile of chromium in the tissues of rockfish is dependent on the exposure periods and chromium concentration. After 4 weeks, the order of chromium accumulation in tissues was liver>kidney>spleen>intestine>gill>muscle. The dietary chromium exposure decreased the growth rate and hepatosomatic index of rockfish. The major hematological findings were significant decrease in the red blood cell (RBC) count, hematocrit (Ht) value, and hemoglobin (Hb) concentration exposed to ≥120 mg/kg chromium concentrations. The dietary chromium exposure (≥120 mg/kg) led to notable increase in glucose, cholesterol, glutamic oxalate transaminase (GOT), and glutamic pyruvate transaminase (GPT) in plasma, whereas there was no considerable change in calcium, magnesium, total protein, and alkaline phosphatase (ALP). The results indicated that the dietary chromium exposure to rockfish can induce significant chromium accumulation in the specific tissues, inhibition of growth, and hematological alterations. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. The impact of chromium nanoaquacitrate and chromium chloride on the antioxidant system of cow’s organism and biological value of theis milk

    OpenAIRE

    KHOMYN M.M.; FEDORUK R.S.; KROPYVKA S.Y.

    2011-01-01

    The data about the impact of chromium chloride and chromium nanoaquacitrate supplement on antioxidant status of cow’s organism for 2 month and 4 month after calving have been presented. It was sound addition of chromium chloride and chromium nanoaquacitrate (0.1 mg Cr/kg/day and 2.7 mcg Cr/kg/day respectively to the diet of II and III experimental groups contributes to a higher content of reduced glutathione, retinol and α-tokoferol in their blood. It was shown increasing of activity of catal...

  20. Plate shell structures of glass

    DEFF Research Database (Denmark)

    Bagger, Anne

    to their curved shape. A plate shell structure maintains a high stiffness-to-weight ratio, while facilitating the use of plane structural elements. The study focuses on using laminated glass panes for the load bearing facets. Various methods of generating a plate shell geometry are suggested. Together with Ghent......, such as facet size, imperfections, and connection characteristics. The critical load is compared to that of a similar, but smoothly curved, shell structure. Based on the investigations throughout the study, a set of guidelines for the structural design of plate shells of glass is proposed....