WorldWideScience

Sample records for hard calcified tissue

  1. Detection of hydroxyapatite in calcified cardiovascular tissues.

    Science.gov (United States)

    Lee, Jae Sam; Morrisett, Joel D; Tung, Ching-Hsuan

    2012-10-01

    The objective of this study is to develop a method for selective detection of the calcific (hydroxyapatite) component in human aortic smooth muscle cells in vitro and in calcified cardiovascular tissues ex vivo. This method uses a novel optical molecular imaging contrast dye, Cy-HABP-19, to target calcified cells and tissues. A peptide that mimics the binding affinity of osteocalcin was used to label hydroxyapatite in vitro and ex vivo. Morphological changes in vascular smooth muscle cells were evaluated at an early stage of the mineralization process induced by extrinsic stimuli, osteogenic factors and a magnetic suspension cell culture. Hydroxyapatite components were detected in monolayers of these cells in the presence of osteogenic factors and a magnetic suspension environment. Atherosclerotic plaque contains multiple components including lipidic, fibrotic, thrombotic, and calcific materials. Using optical imaging and the Cy-HABP-19 molecular imaging probe, we demonstrated that hydroxyapatite components could be selectively distinguished from various calcium salts in human aortic smooth muscle cells in vitro and in calcified cardiovascular tissues, carotid endarterectomy samples and aortic valves, ex vivo. Hydroxyapatite deposits in cardiovascular tissues were selectively detected in the early stage of the calcification process using our Cy-HABP-19 probe. This new probe makes it possible to study the earliest events associated with vascular hydroxyapatite deposition at the cellular and molecular levels. This target-selective molecular imaging probe approach holds high potential for revealing early pathophysiological changes, leading to progression, regression, or stabilization of cardiovascular diseases. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  2. LIBS analysis of artificial calcified tissues matrices.

    Science.gov (United States)

    Kasem, M A; Gonzalez, J J; Russo, R E; Harith, M A

    2013-04-15

    In most laser-based analytical methods, the reproducibility of quantitative measurements strongly depends on maintaining uniform and stable experimental conditions. For LIBS analysis this means that for accurate estimation of elemental concentration, using the calibration curves obtained from reference samples, the plasma parameters have to be kept as constant as possible. In addition, calcified tissues such as bone are normally less "tough" in their texture than many samples, especially metals. Thus, the ablation process could change the sample morphological features rapidly, and result in poor reproducibility statistics. In the present work, three artificial reference sample sets have been fabricated. These samples represent three different calcium based matrices, CaCO3 matrix, bone ash matrix and Ca hydroxyapatite matrix. A comparative study of UV (266 nm) and IR (1064 nm) LIBS for these three sets of samples has been performed under similar experimental conditions for the two systems (laser energy, spot size, repetition rate, irradiance, etc.) to examine the wavelength effect. The analytical results demonstrated that UV-LIBS has improved reproducibility, precision, stable plasma conditions, better linear fitting, and the reduction of matrix effects. Bone ash could be used as a suitable standard reference material for calcified tissue calibration using LIBS with a 266 nm excitation wavelength. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Nuclear analytical methods for trace element studies in calcified tissues

    International Nuclear Information System (INIS)

    Chaudhry, M.A.; Chaudhry, M.N.

    2001-01-01

    Full text: Various nuclear analytical methods have been developed and applied to determine the elemental composition of calcified tissues (teeth and bones). Fluorine was determined by prompt gamma activation analysis through the 19 F(p,ag) 16 O reaction. Carbon was measured by activation analysis with He-3 ions, and the technique of Proton-Induced X-ray Emission (PIXE) was applied to simultaneously determine Ca, P, and trace elements in well-documented teeth. Dental hard tissues, enamel, dentine, cement, and their junctions, as well as different parts of the same tissue, were examined separately. Furthermore, using a Proton Microprobe, we measured the surface distribution of F and other elements on and around carious lesions on the enamel. The depth profiles of F, and other elements, were also measured right up to the amelodentin junction

  4. Calcified-tissue investigations using synchrotron x-ray microscopy

    International Nuclear Information System (INIS)

    Jones, K.W.; Spanne, P.; Schidlovsky, G.; Dejun, X.; Bockman, R.S.; Hammond, P.B.; Bornschein, R.L.; Hoeltzel, D.A.

    1990-10-01

    Synchrotron x-ray microscopy (SXRM) in both emission and absorption modes has been used to examine elemental distributions in specimens of rat tibia, human deciduous teeth, and an orthopedic implant phantom. The work was performed with a spatial resolution of 8 μm for the emission work and 25 μm for the absorption work. The results illustrate the usefulness of SXRM for measurements of different types of calcified tissue. 3 figs

  5. New perspectives on rare connective tissue calcifying diseases.

    Science.gov (United States)

    Rashdan, Nabil A; Rutsch, Frank; Kempf, Hervé; Váradi, András; Lefthériotis, Georges; MacRae, Vicky E

    2016-06-01

    Connective tissue calcifying diseases (CTCs) are characterized by abnormal calcium deposition in connective tissues. CTCs are caused by multiple factors including chronic diseases (Type II diabetes mellitus, chronic kidney disease), the use of pharmaceuticals (e.g. warfarin, glucocorticoids) and inherited rare genetic diseases such as pseudoxanthoma elasticum (PXE), generalized arterial calcification in infancy (GACI) and Keutel syndrome (KTLS). This review explores our current knowledge of these rare inherited CTCs, and highlights the most promising avenues for pharmaceutical intervention. Advancing our understanding of rare inherited forms of CTC is not only essential for the development of therapeutic strategies for patients suffering from these diseases, but also fundamental to delineating the mechanisms underpinning acquired chronic forms of CTC. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Accelerator based nuclear analytical methods for trace element studies in materials- calcified tissues

    International Nuclear Information System (INIS)

    Chaudhri, M. Anwar

    2006-01-01

    Full text: Various nuclear analytical methods have been developed and applied to determine the elemental composition of calcified tissues (teeth and bones). Fluorine was determined by prompt gamma activation analysis through the 19 F(p,αγ) 16 O reaction. Carbon was measured by activation analysis with He-3 ions, and the technique of Proton-Induced X-ray Emission (PIXE) was applied to simultaneously determine Ca, P, and trace elements in well-documented teeth. Dental hard tissues: enamel, dentine, cementum, and their junctions, as well as different parts of the same tissue, were examined separately. Furthermore, using a Proton Microprobe, we measured the surface distribution of F and other elements on and around carious lesions on the enamel. The depth profiles of F, and other elements, were also measured right up to the amelodentin junction. (author)

  7. A color contrast aided density imaging technique to differentiate between dental hard tissues and its relevance

    Directory of Open Access Journals (Sweden)

    Devi Charan Shetty

    2011-01-01

    Full Text Available Aim: Radiographic interpretation of a disease requires knowledge about normal structures. The calcifying jaw diseases can range from radiolucent areas to varying degrees of calcification. Therefore, it is vital to differentiate radiographically between various hard tissues. Materials and Methods: We have illustrated the use of computed tomography scan to quantify the calcified structures as dentin and enamel in a case of ameloblastic fibro-odontoma. Results: The enamel, dentin and cementum showed different values. Conclusion: The "Dentascan" can be used to distinguish the hard tissues in a variety of calcifying diseases of jaws.

  8. Br-rich tips of calcified crab claws are less hard but more fracture resistant: a comparison of mineralized and heavy-element biological materials.

    Science.gov (United States)

    Schofield, Robert M S; Niedbala, Jack C; Nesson, Michael H; Tao, Ye; Shokes, Jacob E; Scott, Robert A; Latimer, Matthew J

    2009-06-01

    We find that the spoon-like tips of the chelipeds (large claws) of the crab Pachygrapsus crassipes differ from the rest of the claw in that they are not calcified, but instead contain about 1% bromine--thus they represent a new example of a class of structural biological materials that contain heavy elements such as Zn, Mn, Fe, Cu, and Br bound in an organic matrix. X-ray absorption spectroscopy data suggest that the bromine is bound to phenyl rings, possibly in tyrosine. We measure a broad array of mechanical properties of a heavy-element biological material for the first time (abrasion resistance, coefficient of kinetic friction, energy of fracture, hardness, modulus of elasticity and dynamic mechanical properties), and we make a direct comparison with a mineralized tissue. Our results suggest that the greatest advantage of bromine-rich cuticle over calcified cuticle is resistance to fracture (the energy of fracture is about an order of magnitude greater than for calcified cuticle). The greatest advantage relative to unenriched cuticle, represented by ant mandible cuticle, is a factor of about 1.5 greater hardness and modulus of elasticity.The spoon-like tips gain additional fracture resistance from the orientation of the constituent laminae and from the viscoelasticity of the material. We suggest that fracture resistance is of greater importance in smaller organisms, and we speculate that one function of heavy elements in structural biological materials is to reduce molecular resonant frequencies and thereby increase absorption of energy from impacts.

  9. A Hard Ball for a Tennis Player: A Rare Case of Large Calcifying Sertoli Cell Testicular Tumor

    Directory of Open Access Journals (Sweden)

    Simone Albisinni

    2017-07-01

    Full Text Available A 46 year old tennis player was addressed to our clinic after incidental finding of right testicular calcification on plain x-ray of the spine. Urologic consultation revealed a hard non-tender testicular mass which required inguinal orchiectomy. Final histology revealed large cell calcifying Sertoli cell tumor: we herein present the case and review current physiopathology of such rare testicular disease.

  10. Multiscale mechanics of hierarchical structure/property relationships in calcified tissues and tissue/material interfaces

    International Nuclear Information System (INIS)

    Katz, J. Lawrence; Misra, Anil; Spencer, Paulette; Wang, Yong; Bumrerraj, Sauwanan; Nomura, Tsutomu; Eppell, Steven J.; Tabib-Azar, Massood

    2007-01-01

    This paper presents a review plus new data that describes the role hierarchical nanostructural properties play in developing an understanding of the effect of scale on the material properties (chemical, elastic and electrical) of calcified tissues as well as the interfaces that form between such tissues and biomaterials. Both nanostructural and microstructural properties will be considered starting with the size and shape of the apatitic mineralites in both young and mature bovine bone. Microstructural properties for human dentin and cortical and trabecular bone will be considered. These separate sets of data will be combined mathematically to advance the effects of scale on the modeling of these tissues and the tissue/biomaterial interfaces as hierarchical material/structural composites. Interfacial structure and properties to be considered in greatest detail will be that of the dentin/adhesive (d/a) interface, which presents a clear example of examining all three material properties, (chemical, elastic and electrical). In this case, finite element modeling (FEA) was based on the actual measured values of the structure and elastic properties of the materials comprising the d/a interface; this combination provides insight into factors and mechanisms that contribute to premature failure of dental composite fillings. At present, there are more elastic property data obtained by microstructural measurements, especially high frequency ultrasonic wave propagation (UWP) and scanning acoustic microscopy (SAM) techniques. However, atomic force microscopy (AFM) and nanoindentation (NI) of cortical and trabecular bone and the dentin-enamel junction (DEJ) among others have become available allowing correlation of the nanostructural level measurements with those made on the microstructural level

  11. Live tissue imaging shows reef corals elevate pH under their calcifying tissue relative to seawater.

    Directory of Open Access Journals (Sweden)

    Alexander Venn

    Full Text Available The threat posed to coral reefs by changes in seawater pH and carbonate chemistry (ocean acidification raises the need for a better mechanistic understanding of physiological processes linked to coral calcification. Current models of coral calcification argue that corals elevate extracellular pH under their calcifying tissue relative to seawater to promote skeleton formation, but pH measurements taken from the calcifying tissue of living, intact corals have not been achieved to date. We performed live tissue imaging of the reef coral Stylophora pistillata to determine extracellular pH under the calcifying tissue and intracellular pH in calicoblastic cells. We worked with actively calcifying corals under flowing seawater and show that extracellular pH (pHe under the calicoblastic epithelium is elevated by ∼0.5 and ∼0.2 pH units relative to the surrounding seawater in light and dark conditions respectively. By contrast, the intracellular pH (pHi of the calicoblastic epithelium remains stable in the light and dark. Estimates of aragonite saturation states derived from our data indicate the elevation in subcalicoblastic pHe favour calcification and may thus be a critical step in the calcification process. However, the observed close association of the calicoblastic epithelium with the underlying crystals suggests that the calicoblastic cells influence the growth of the coral skeleton by other processes in addition to pHe modification. The procedure used in the current study provides a novel, tangible approach for future investigations into these processes and the impact of environmental change on the cellular mechanisms underpinning coral calcification.

  12. Dual-energy CT head bone and hard plaque removal for quantification of calcified carotid stenosis: utility and comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Uotani, Kensuke; Watanabe, Yoshiyuki; Higashi, Masahiro; Nakazawa, Tetsuro; Kono, Atsushi K.; Hori, Yoshiro; Fukuda, Tetsuya; Kanzaki, Suzu; Yamada, Naoaki; Naito, Hiroaki; Itoh, Toshihide; Sugimura, Kazuro

    2009-01-01

    We evaluated quantification of calcified carotid stenosis by dual-energy (DE) CTA and dual-energy head bone and hard plaque removal (DE hard plaque removal) and compared the results to those of digital subtraction angiography (DSA). Eighteen vessels (13 patients) with densely calcified carotid stenosis were examined by dual-source CT in the dual-energy mode (tube voltages 140 kV and 80 kV). Head bone and hard plaques were removed from the dual-energy images by using commercial software. Carotid stenosis was quantified according to NASCET criteria on MIP images and DSA images at the same plane. Correlation between DE CTA and DSA was determined by cross tabulation. Accuracies for stenosis detection and grading were calculated. Stenosis could be evaluated in all vessels by DE CTA after applying DE hard plaque removal. In contrast, conventional CTA failed to show stenosis in 13 out of 18 vessels due to overlapping hard plaque. Good correlation between DE plaque removal images and DSA images was observed (r 2 =0.9504) for stenosis grading. Sensitivity and specificity to detect hemodynamically relevant (>70%) stenosis was 100% and 92%, respectively. Dual-energy head bone and hard plaque removal is a promising tool for the evaluation of densely calcified carotid stenosis. (orig.)

  13. Application of a nuclear microprobe to the study of calcified tissues

    Science.gov (United States)

    Coote, Graeme E.; Vickridge, Ian C.

    1988-03-01

    The mineral fraction of calcified tissue is largely calcium hydroxyapatite (bones and teeth) or calcium carbonate (shells and fish otoliths). Apatite has such a strong affinity for fluoride ions that the F/Ca ratio can vary markedly with position in a bone or tooth, depending on the amount of fluoride present at the time of calcification or partial recrystallization. New biological information can be obtained by introducing extra fluoride into the diet of an animal and using a microprobe later to scan sections of bones or teeth. In suitable burial sites extra fluoride is introduced after death, and the new distribution may have applications in forensic science and archaeology. Fish otoliths are also of interest since a new carbonate layer is formed each day and the distribution of trace elements may record some aspects of the fish's life history. Results from the following studies are presented: fluorine distributions in the teeth of sheep which ingested extra fluoride for known periods; distributions of calcium and fluorine in femurs of rats which drank water high in fluoride for periods from 2 to 15 weeks; calcium and fluorine distributions in artificially-prepared lesions in tooth enamel; diffusion profiles in archaeological human teeth and animal bones; patterns in the strontium/calcium ratio in sectioned otoliths of several species of fish.

  14. Backscattered electron imaging: The role in calcified tissue and implant analysis

    International Nuclear Information System (INIS)

    Bloebaum, R.D.; Bachus, K.N.; Boyce, T.M.

    1990-01-01

    The working distance and tilt studies helped to clarify the influences of specimen variability when the BSE mode is used in calcified tissue research. This work has shown that the BSEPs of cortical bone may be accurately maintained within 2 percent error over a 10 degree range of tilt, or 300 microns working distance variation. If future bone and implant investigators wish to conduct accurate, quantitative mineral microanalysis in bone, then standard grinding and polishing techniques should be adequate if calibration procedures are developed. The BSEP characteristics of the pure metals make them suitable to be used for calibrating the BSE signal. BSE analysis, with correlated biomechanical studies, will lead us to a better understanding of the relationships between structure, function, and mineral content in bone. On-line BSEP analysis techniques will expand our understanding of the mineralization events in bone which are associated with aging, weightlessness, pharmaceutical therapies, and the presence of biomaterials. The future of the BSE imaging technology and the contributions to be made in understanding the histometry, biomechanics and mineral content of bone as well as bone's response to implant materials has just begun to unfold. 74 references

  15. CO2 laser milling of hard tissue

    Science.gov (United States)

    Werner, Martin; Ivanenko, Mikhail; Harbecke, Daniela; Klasing, Manfred; Steigerwald, Hendrik; Hering, Peter

    2007-02-01

    Drilling of bone and tooth tissue belongs to recurrent medical procedures (screw- and pin-bores, bores for implant inserting, trepanation etc.). Small round bores can be in general quickly produced with mechanical drills. Problems arise however by angled drilling, by the necessity to fulfill the drilling without damaging of sensitive soft tissue beneath the bone, or by the attempt to mill precisely noncircular small cavities. We present investigations on laser hard tissue "milling", which can be advantageous for solving these problems. The "milling" is done with a CO2 laser (10.6 μm) with pulse duration of 50 - 100 μs, combined with a PC-controlled galvanic beam scanner and with a fine water-spray, which helps to avoid thermal side-effects. The damaging of underlying soft tissue can be prevented through control of the optical or acoustical ablation signal. The ablation of hard tissue is accompanied with a strong glowing, which is absent during the laser beam action on soft tissue. The acoustic signals from the diverse tissue types exhibit distinct differences in the spectral composition. Also computer image analysis could be a useful tool to control the operation. Laser "milling" of noncircular cavities with 1 - 4 mm width and about 10 mm depth is particularly interesting for dental implantology. In ex-vivo investigations we found conditions for fast laser "milling" of the cavities without thermal damage and with minimal tapering. It included exploration of different filling patterns (concentric rings, crosshatch, parallel lines and their combinations), definition of maximal pulse duration, repetition rate and laser power, optimal position of the spray. The optimized results give evidences for the applicability of the CO2 laser for biologically tolerable "milling" of deep cavities in the hard tissue.

  16. Electrochemical removal of metallic implants from Technovit 9100 New embedded hard and soft tissues prior to histological sectioning.

    Science.gov (United States)

    Willbold, Elmar; Reebmann, Mattias; Jeffries, Richard; Witte, Frank

    2013-11-01

    Solid metallic implants in soft or hard tissues are serious challenges for histological processing. However, metallic implants are more frequently used in e.g. cardiovascular or orthopaedic therapies. Before clinical use, these devices need to be tested thoroughly in a biological environment and histological analysis of their biocompatibility is a major requirement. To allow the histological analysis of metallic implants in tissues especially in calcified hard tissues, we describe a method for embedding these tissues in the resin Technovit 9100 New and removing the metallic implants by electrochemical dissolution. With the combination of these two processes, we are able to achieve 5 μm thick sections from soft or hard tissues with a superior preservation of tissue architecture and especially the implant-tissue interface. These sections can be stained by classical stainings, immunohistochemical and enzymehistochemical as well as DNA-based staining methods.

  17. Imaging the hard/soft tissue interface.

    Science.gov (United States)

    Bannerman, Alistair; Paxton, Jennifer Z; Grover, Liam M

    2014-03-01

    Interfaces between different tissues play an essential role in the biomechanics of native tissues and their recapitulation is now recognized as critical to function. As a consequence, imaging the hard/soft tissue interface has become increasingly important in the area of tissue engineering. Particularly as several biotechnology based products have made it onto the market or are close to human trials and an understanding of their function and development is essential. A range of imaging modalities have been developed that allow a wealth of information on the morphological and physical properties of samples to be obtained non-destructively in vivo or via destructive means. This review summarizes the use of a selection of imaging modalities on interfaces to date considering the strengths and weaknesses of each. We will also consider techniques which have not yet been utilized to their full potential or are likely to play a role in future work in the area.

  18. Computed tomography of the soft tissues of the shoulder. Pt. 3. Calcifying tendinitis of the rotator cuff

    Energy Technology Data Exchange (ETDEWEB)

    Dihlmann, W.; Bandick, J.

    1988-01-01

    Computed tomography of the soft tissue of the shoulder in cases of calcifying tendinitis of the rotator cuff provides the following information: 1. Localisation of the calcium deposits within the rotator cuff. 2. Contours and density of the calcium deposits correlated with the clinical findings as described by Uhthoff et al. Ill-defined contours and non-homogeneous deposits are associated with more severe clinical features. 3. Computed tomography shows that apatite particles, which are not visible radiologically, may penetrate into the shoulder joint and produce synovitis with an effusion. This is of importance in local therapy.

  19. Exercise does not affect stiffness and mineralisation of third metacarpal condylar subarticular calcified tissues in 2 year old thoroughbred racehorses

    Directory of Open Access Journals (Sweden)

    VL Ferguson

    2008-09-01

    Full Text Available Impact exercise has a profound effect in increasing volumetric density of epiphyseal bone, as clearly shown in 2 year old thoroughbred racehorses from which we derived the tissue studied in the present investigation. Here, we asked the question whether the fabric-level properties of the mineralised tissues immediately below hyaline articular cartilage which transmit the extra loads are themselves altered in consequence. We therefore studied the nanoindentation elastic modulus and its relationship to the concentration of mineral determined by quantitative backscattered electron imaging in the heavily loaded palmar medial and lateral condyles of the distal third metacarpal bone (Mc3 of 4 untrained and 4 trained 2-year old Thoroughbred racehorses. We found no difference between trained and untrained horses in either subchondral bone or calcified cartilage in the mean stiffness or mineral content or their correlation. Thus neither articular calcified cartilage nor the immediately adjacent subchondral bone were affected by exercise, even though they transmitted the higher load associated with athletic training through to the deeper bone, which itself responded floridly to exercise. Under the circumstances of this experiment and at least in the very small regions studied, therefore, the structure of these two tissues was apparently optimised to function.

  20. The strength of a calcified tissue depends in part on the molecular structure and organization of its constituent mineral crystals in their organic matrix

    Science.gov (United States)

    Landis, W. J.

    1995-01-01

    High-voltage electron-microscopic tomographic (3D) studies of the ultrastructural interaction between mineral and organic matrix in a variety of calcified tissues reveal different crystal structural and organizational features in association with their respective organic matrices. In brittle or weak pathologic or ectopic calcifications, including examples of osteogenesis imperfecta, calciphylaxis, calcergy, and dermatomyositis, hydroxyapatite crystals occur in various sizes and shapes and are oriented and aligned with respect to collagen in a manner which is distinct from that found in normal calcified tissues. A model of collagen-mineral interaction is proposed which may account for the observed crystal structures and organization. The results indicate that the ultimate strength, support, and other mechanical properties provided by a calcified tissue are dependent in part upon the molecular structure and arrangement of its constituent mineral crystals within their organic matrix.

  1. 3D Bioprinting Technologies for Hard Tissue and Organ Engineering

    OpenAIRE

    Wang, Xiaohong; Ao, Qiang; Tian, Xiaohong; Fan, Jun; Wei, Yujun; Hou, Weijian; Tong, Hao; Bai, Shuling

    2016-01-01

    Hard tissues and organs, including the bones, teeth and cartilage, are the most extensively exploited and rapidly developed areas in regenerative medicine field. One prominent character of hard tissues and organs is that their extracellular matrices mineralize to withstand weight and pressure. Over the last two decades, a wide variety of 3D printing technologies have been adapted to hard tissue and organ engineering. These 3D printing technologies have been defined as 3D bioprinting. Especial...

  2. 3D Bioprinting Technologies for Hard Tissue and Organ Engineering

    Science.gov (United States)

    Wang, Xiaohong; Ao, Qiang; Tian, Xiaohong; Fan, Jun; Wei, Yujun; Hou, Weijian; Tong, Hao; Bai, Shuling

    2016-01-01

    Hard tissues and organs, including the bones, teeth and cartilage, are the most extensively exploited and rapidly developed areas in regenerative medicine field. One prominent character of hard tissues and organs is that their extracellular matrices mineralize to withstand weight and pressure. Over the last two decades, a wide variety of 3D printing technologies have been adapted to hard tissue and organ engineering. These 3D printing technologies have been defined as 3D bioprinting. Especially for hard organ regeneration, a series of new theories, strategies and protocols have been proposed. Some of the technologies have been applied in medical therapies with some successes. Each of the technologies has pros and cons in hard tissue and organ engineering. In this review, we summarize the advantages and disadvantages of the historical available innovative 3D bioprinting technologies for used as special tools for hard tissue and organ engineering. PMID:28773924

  3. 3D Bioprinting Technologies for Hard Tissue and Organ Engineering

    Directory of Open Access Journals (Sweden)

    Xiaohong Wang

    2016-09-01

    Full Text Available Hard tissues and organs, including the bones, teeth and cartilage, are the most extensively exploited and rapidly developed areas in regenerative medicine field. One prominent character of hard tissues and organs is that their extracellular matrices mineralize to withstand weight and pressure. Over the last two decades, a wide variety of 3D printing technologies have been adapted to hard tissue and organ engineering. These 3D printing technologies have been defined as 3D bioprinting. Especially for hard organ regeneration, a series of new theories, strategies and protocols have been proposed. Some of the technologies have been applied in medical therapies with some successes. Each of the technologies has pros and cons in hard tissue and organ engineering. In this review, we summarize the advantages and disadvantages of the historical available innovative 3D bioprinting technologies for used as special tools for hard tissue and organ engineering.

  4. 3D Bioprinting Technologies for Hard Tissue and Organ Engineering.

    Science.gov (United States)

    Wang, Xiaohong; Ao, Qiang; Tian, Xiaohong; Fan, Jun; Wei, Yujun; Hou, Weijian; Tong, Hao; Bai, Shuling

    2016-09-27

    Hard tissues and organs, including the bones, teeth and cartilage, are the most extensively exploited and rapidly developed areas in regenerative medicine field. One prominent character of hard tissues and organs is that their extracellular matrices mineralize to withstand weight and pressure. Over the last two decades, a wide variety of 3D printing technologies have been adapted to hard tissue and organ engineering. These 3D printing technologies have been defined as 3D bioprinting. Especially for hard organ regeneration, a series of new theories, strategies and protocols have been proposed. Some of the technologies have been applied in medical therapies with some successes. Each of the technologies has pros and cons in hard tissue and organ engineering. In this review, we summarize the advantages and disadvantages of the historical available innovative 3D bioprinting technologies for used as special tools for hard tissue and organ engineering.

  5. Two cases report of Calcifying Odontogenic Cyst

    International Nuclear Information System (INIS)

    Lee, Byung Do; Lee, Wan; Paeng, Jun Young; Lee, Jun; Choi, Moon Ki; Son, Hyun Jin

    2009-01-01

    The calcifying odontogenic cyst (COC) is a rare disorder of the jaws and shows various radiographic features. The purpose of this study is to describe the different radiographic appearances of 2 cases of COC. Case 1 was located in the posterior maxilla extending into maxillary sinus, showing unilocular radiolucency with a well-defined margin. Cortical bone expansion and thinning were prominent. Root resorption of adjacent teeth was apparent. Case 2 showed unilocular radiolucency with a calcified material. Calcification was supposed to be dystrophic dental hard structures, detected at the periphery of the lesion. Ghost cell and proliferation of ameloblastoma-like tissues were common features for these two lesions on histopathological findings. This reports presented common and atypical radiographic features of the COC.

  6. Comparative aspects of calcium dynamics in calcified tissues in the goldfish Carassius auratus

    International Nuclear Information System (INIS)

    Ichii, Taro; Mugiya, Yasuo

    1983-01-01

    The comparative nature of calcium physiology in bone, scales and otoliths was studied in young goldfish, Carassius auratus. Net calcium uptake by the fish was estimated to be 143 μg/g body weight/day. Of that, 79 % was distributed in bone, 13 % in scales, 3.5 % in otoliths and 4.5 % in soft tissues. Scales showed the highest incorporation of 45 Ca per mg-tissue weight after 1 or 2 days in 45 Ca-containing water; bone came second and otoliths last. However, 35 days after transfer to non-radioactive water, the order of descending radioactivity had changed to otoliths, bone and scales, reflecting different rates of calcium turnover. In bone, prelabeled 45 Ca activity increased for the first 2 days after transfer and then decreased gradually (biological half-life, Tsub(0.5) = 94 days). In otoliths, prelabeled radioactivity consistently increased for 35 days. Scales showed two phases of calcium turnover. They lost about 33 % of their prelabeled radioactivity during the first 7 days (Tsub(0.5) = 10.5 days) in non-radioactive water, but thereafter the rate of decrease slowed down greatly (Tsub(0.5) = 210 days). These two phases of calcium turnover were found in the osseous layer (including calcium crystals in the fibrillary plate) of scales, indicating the presence of physiologically labile as well as stable forms of calcium in the layer. (author)

  7. Comparative aspects of calcium dynamics in calcified tissues in the goldfish Carassius auratus

    Energy Technology Data Exchange (ETDEWEB)

    Ichii, Taro; Mugiya, Yasuo (Hokkaido Univ., Hakodate (Japan). Faculty of Fisheries)

    1983-07-01

    The comparative nature of calcium physiology in bone, scales and otoliths was studied in young goldfish, Carassius auratus. Net calcium uptake by the fish was estimated to be 143 ..mu..g/g body weight/day. Of that, 79 % was distributed in bone, 13 % in scales, 3.5 % in otoliths and 4.5 % in soft tissues. Scales showed the highest incorporation of /sup 45/Ca per mg-tissue weight after 1 or 2 days in /sup 45/Ca-containing water; bone came second and otoliths last. However, 35 days after transfer to non-radioactive water, the order of descending radioactivity had changed to otoliths, bone and scales, reflecting different rates of calcium turnover. In bone, prelabeled /sup 45/Ca activity increased for the first 2 days after transfer and then decreased gradually (biological half-life, Tsub(0.5) = 94 days). In otoliths, prelabeled radioactivity consistently increased for 35 days. Scales showed two phases of calcium turnover. They lost about 33 % of their prelabeled radioactivity during the first 7 days (Tsub(0.5) = 10.5 days) in non-radioactive water, but thereafter the rate of decrease slowed down greatly (Tsub(0.5) = 210 days). These two phases of calcium turnover were found in the osseous layer (including calcium crystals in the fibrillary plate) of scales, indicating the presence of physiologically labile as well as stable forms of calcium in the layer.

  8. Ultrashort pulse laser processing of hard tissue, dental restoration materials, and biocompatibles

    Science.gov (United States)

    Yousif, A.; Strassl, M.; Beer, F.; Verhagen, L.; Wittschier, M.; Wintner, E.

    2007-07-01

    During the last few years, ultra-short laser pulses have proven their potential for application in medical tissue treatment in many ways. In hard tissue ablation, their aptitude for material ablation with negligible collateral damage provides many advantages. Especially teeth representing an anatomically and physiologically very special region with less blood circulation and lower healing rates than other tissues require most careful treatment. Hence, overheating of the pulp and induction of microcracks are some of the most problematic issues in dental preparation. Up till now it was shown by many authors that the application of picosecond or femtosecond pulses allows to perform ablation with very low damaging potential also fitting to the physiological requirements indicated. Beside the short interaction time with the irradiated matter, scanning of the ultra-short pulse trains turned out to be crucial for ablating cavities of the required quality. One main reason for this can be seen in the fact that during scanning the time period between two subsequent pulses incident on the same spot is so much extended that no heat accumulation effects occur and each pulse can be treated as a first one with respect to its local impact. Extension of this advantageous technique to biocompatible materials, i.e. in this case dental restoration materials and titanium plasma-sprayed implants, is just a matter of consequence. Recently published results on composites fit well with earlier data on dental hard tissue. In case of plaque which has to be removed from implants, it turns out that removal of at least the calcified version is harder than tissue removal. Therefore, besides ultra-short lasers, also Diode and Neodymium lasers, in cw and pulsed modes, have been studied with respect to plaque removal and sterilization. The temperature increase during laser exposure has been experimentally evaluated in parallel.

  9. Hard and soft tissue surgical complications in dental implantology.

    Science.gov (United States)

    Aziz, Shahid R

    2015-05-01

    This article discusses surgical complications associated with the placement of dental implants, specifically focusing on how they occur (etiology), as well as their management and prevention. Dental implant surgical complications can be classified into those of hard and soft tissues. In general, complications can be avoided with thorough preoperative treatment planning and proper surgical technique. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. CO II laser free-form processing of hard tissue

    Science.gov (United States)

    Werner, Martin; Klasing, Manfred; Ivanenko, Mikhail; Harbecke, Daniela; Steigerwald, Hendrik; Hering, Peter

    2007-07-01

    Drilling and surface processing of bone and tooth tissue belongs to standard medical procedures (bores and embeddings for implants, trepanation etc.). Small circular bores can be generally quickly produced with mechanical drills. However problems arise at angled drilling, the need to execute drilling procedures without damaging of sensitive soft tissue structures underneath the bone or the attempt to mill small non-circular cavities in hard tissue with high precision. We present investigations on laser hard tissue "milling", which can be advantageous for solving these problems. The processing of bone is done with a CO II laser (10.6 μm) with pulse durations of 50 - 100 μs, combined with a PC-controlled fast galvanic laser beam scanner and a fine water-spray, which helps keeping the ablation process effective and without thermal side-effects. Laser "milling" of non-circular cavities with 1 - 4 mm width and about 10 mm depth can be especially interesting for dental implantology. In ex-vivo investigations we found conditions for fast laser processing of these cavities without thermal damage and with minimised tapering. It included the exploration of different filling patterns (concentric rings, crosshatch, parallel lines, etc.), definition of maximal pulse duration, repetition rate and laser power, and optimal water spray position. The optimised results give evidence for the applicability of pulsed CO II lasers for biologically tolerable effective processing of deep cavities in hard tissue.

  11. Early outcome of high energy Laser (Excimer) facilitated coronary angioplasty ON hARD and complex calcified and balloOn-resistant coronary lesions: LEONARDO Study

    International Nuclear Information System (INIS)

    Ambrosini, Vittorio; Sorropago, Giovanni; Laurenzano, Eugenio; Golino, Luca; Casafina, Alfredo; Schiano, Vittorio; Gabrielli, Gabriele; Ettori, Federica; Chizzola, Giuliano; Bernardi, Guglielmo; Spedicato, Leonardo; Armigliato, Pietro; Spampanato, Carmine; Furegato, Martina

    2015-01-01

    Aim: An innovative xenon–chlorine (excimer) pulsed laser catheter (ELCA X80) has been recently used for the treatment of complex coronary lesions, as calcified stenosis, chronic total occlusions and non-compliant plaques. Such complex lesions are difficult to adequately treat with balloon angioplasty and/or intracoronary stenting. The aim of this study was to examine the acute outcome of this approach on a cohort of patients with coronary lesions. Methods and Results: Eighty patients with 100 lesions were enrolled through four centers, and excimer laser coronary angioplasty was performed on 96 lesions (96%). Safety and effectiveness data were compared between patients treated with standard laser therapy and those treated with increased laser therapy. Laser success was obtained in 90 lesions (93.7%), procedural success was reached in 88 lesions (91.7%), and clinical success in was obtained in 87 lesions (90.6%). There was no perforation, major side branch occlusion, spasm, no-reflow phenomenon, dissection nor acute vessel closure. Increased laser parameters were used successfully for 49 resistant lesions without complications. Conclusions: This study suggests that laser-facilitated coronary angioplasty is a simple, safe and effective device for the management of complex coronary lesions. Furthermore, higher laser energy levels delivered by this catheter improved the device performance without increasing complications. - Highlights: • We planned this multicenter study to examine the acute outcome of an innovative xenon–chlorine (excimer) pulsed laser catheter (ELCA X80) for treatment of complex coronary lesions. • We enrolled 80 patients with 100 lesions and performed excimer laser coronary angioplasty in 96 lesions (96%). • Laser success was obtained in 90 lesions (93.7%), procedural success was reached in 88 lesions (91.7%), and clinical success was obtained in 87 lesions (90.6%). • Increased laser parameters were used successfully for 49 resistant

  12. Early outcome of high energy Laser (Excimer) facilitated coronary angioplasty ON hARD and complex calcified and balloOn-resistant coronary lesions: LEONARDO Study

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosini, Vittorio; Sorropago, Giovanni; Laurenzano, Eugenio [Montevergine Clinic, Mercogliano (Italy); Golino, Luca, E-mail: lucagolino.jazz@alice.it [Montevergine Clinic, Mercogliano (Italy); Moriggia-Pelascini Hospital, Gravedona, Como (Italy); Casafina, Alfredo; Schiano, Vittorio [Montevergine Clinic, Mercogliano (Italy); Gabrielli, Gabriele [University Hospital Ospedali Riuniti, Ancona (Italy); Ettori, Federica; Chizzola, Giuliano [Spedali Civili University Hospital, Brescia (Italy); Bernardi, Guglielmo; Spedicato, Leonardo [University Hospital S. Maria Misericordia, Udine (Italy); Armigliato, Pietro [Istituto Italiano Ricerche Mediche, Verona (Italy); Spampanato, Carmine [Telethon Institute of Genetics and Medicine (TIGEM), Naples (Italy); Furegato, Martina [Istituto Italiano Ricerche Mediche, Verona (Italy)

    2015-04-15

    Aim: An innovative xenon–chlorine (excimer) pulsed laser catheter (ELCA X80) has been recently used for the treatment of complex coronary lesions, as calcified stenosis, chronic total occlusions and non-compliant plaques. Such complex lesions are difficult to adequately treat with balloon angioplasty and/or intracoronary stenting. The aim of this study was to examine the acute outcome of this approach on a cohort of patients with coronary lesions. Methods and Results: Eighty patients with 100 lesions were enrolled through four centers, and excimer laser coronary angioplasty was performed on 96 lesions (96%). Safety and effectiveness data were compared between patients treated with standard laser therapy and those treated with increased laser therapy. Laser success was obtained in 90 lesions (93.7%), procedural success was reached in 88 lesions (91.7%), and clinical success in was obtained in 87 lesions (90.6%). There was no perforation, major side branch occlusion, spasm, no-reflow phenomenon, dissection nor acute vessel closure. Increased laser parameters were used successfully for 49 resistant lesions without complications. Conclusions: This study suggests that laser-facilitated coronary angioplasty is a simple, safe and effective device for the management of complex coronary lesions. Furthermore, higher laser energy levels delivered by this catheter improved the device performance without increasing complications. - Highlights: • We planned this multicenter study to examine the acute outcome of an innovative xenon–chlorine (excimer) pulsed laser catheter (ELCA X80) for treatment of complex coronary lesions. • We enrolled 80 patients with 100 lesions and performed excimer laser coronary angioplasty in 96 lesions (96%). • Laser success was obtained in 90 lesions (93.7%), procedural success was reached in 88 lesions (91.7%), and clinical success was obtained in 87 lesions (90.6%). • Increased laser parameters were used successfully for 49 resistant

  13. Calcifying Aponeurotic Fibroma with Osseous Involvement of the Finger: a Case Report with Radiologic and US Findings

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Soo Jung; Ahn, Jae Hong; Kang, Gil Hyun; Lee, Jong Hyeog; Park, Man Soo; Ryu, Dae Sik; Jung, Seung Moon [GangNeung Asan Hospital, University of Ulsan College of Medicine, Gangneung (Korea, Republic of)

    2008-02-15

    Calcifying aponeurotic fibroma is a rare soft tissue tumor that occurs in the distal extremities of children and adolescents. We report ultrasound and X-ray findings of a calcifying aponeurotic fibroma in the finger of a 36-year-old woman, associated with distal phalangeal bone involvement. Calcifying aponeurotic fibroma is a rare, locally aggressive fibroblastic lesion occurring primarily in the palms of the hands and soles of the feet in young children and adolescents under 20 years of age. Clinical presentation is a unique, hard, and painless palpable mass. This soft tissue tumor typically infiltrates into the surrounding fascia or muscle and has a predilection for recurrence after surgical removal. However, bone involvement in calcifying aponeurotic fibroma is a very rare condition and we found only three pediatric cases in the literature. We present the ultrasound and radiographic findings of a calcifying aponeurotic fibroma in the finger of a 36-year-old woman, associated with erosive bone destruction of the distal phalanx. In summary, calcifying aponeurotic fibroma is a rare soft tissue tumor that presents as a painless mass primarily on the volar surface of the hands and plantar aspects of the feet in juveniles, but this tumor should be also included in differential diagnoses of any mass with calcification and adjacent bone involvement in the distal phalanx of the finger. In addition, US could be useful for the preoperative evaluation of digital calcifying aponeurotic fibroma.

  14. Calcifying Aponeurotic Fibroma with Osseous Involvement of the Finger: a Case Report with Radiologic and US Findings

    International Nuclear Information System (INIS)

    Choi, Soo Jung; Ahn, Jae Hong; Kang, Gil Hyun; Lee, Jong Hyeog; Park, Man Soo; Ryu, Dae Sik; Jung, Seung Moon

    2008-01-01

    Calcifying aponeurotic fibroma is a rare soft tissue tumor that occurs in the distal extremities of children and adolescents. We report ultrasound and X-ray findings of a calcifying aponeurotic fibroma in the finger of a 36-year-old woman, associated with distal phalangeal bone involvement. Calcifying aponeurotic fibroma is a rare, locally aggressive fibroblastic lesion occurring primarily in the palms of the hands and soles of the feet in young children and adolescents under 20 years of age. Clinical presentation is a unique, hard, and painless palpable mass. This soft tissue tumor typically infiltrates into the surrounding fascia or muscle and has a predilection for recurrence after surgical removal. However, bone involvement in calcifying aponeurotic fibroma is a very rare condition and we found only three pediatric cases in the literature. We present the ultrasound and radiographic findings of a calcifying aponeurotic fibroma in the finger of a 36-year-old woman, associated with erosive bone destruction of the distal phalanx. In summary, calcifying aponeurotic fibroma is a rare soft tissue tumor that presents as a painless mass primarily on the volar surface of the hands and plantar aspects of the feet in juveniles, but this tumor should be also included in differential diagnoses of any mass with calcification and adjacent bone involvement in the distal phalanx of the finger. In addition, US could be useful for the preoperative evaluation of digital calcifying aponeurotic fibroma

  15. Hard X-ray Microscopic Imaging Of Human Breast Tissues

    Science.gov (United States)

    Park, Sung H.; Kim, Hong T.; Kim, Jong K.; Jheon, Sang H.; Youn, Hwa S.

    2007-01-01

    X-ray microscopy with synchrotron radiation will be a useful tool for innovation of x-ray imaging in clinical and laboratory settings. It helps us observe detailed internal structure of material samples non-invasively in air. And, it also has the potential to solve some tough problems of conventional breast imaging if it could evaluate various conditions of breast tissue effectively. A new hard x-ray microscope with a spatial resolution better than 100 nm was installed at Pohang Light Source, a third generation synchrotron radiation facility in Pohang, Korea. The x-ray energy was set at 6.95 keV, and the x-ray beam was monochromatized by W/B4C monochromator. Condenser and objective zone plates were used as x-ray lenses. Zernike phase plate next to condenser zone plate was introduced for improved contrast imaging. The image of a sample was magnified 30 times by objective zone plate and 20 times by microscope objective, respectively. After additional 10 times digital magnification, the total magnifying power was up to 6000 times in the end. Phase contrast synchrotron images of 10-μm-thick female breast tissue of the normal, fibroadenoma, fibrocystic change and carcinoma cases were obtained. By phase contrast imaging, hard x-rays enable us to observe many structures of breast tissue without sample preparations such as staining or fixation.

  16. Hard X-ray Microscopic Imaging Of Human Breast Tissues

    International Nuclear Information System (INIS)

    Park, Sung H.; Kim, Hong T.; Kim, Jong K.; Jheon, Sang H.; Youn, Hwa S.

    2007-01-01

    X-ray microscopy with synchrotron radiation will be a useful tool for innovation of x-ray imaging in clinical and laboratory settings. It helps us observe detailed internal structure of material samples non-invasively in air. And, it also has the potential to solve some tough problems of conventional breast imaging if it could evaluate various conditions of breast tissue effectively. A new hard x-ray microscope with a spatial resolution better than 100 nm was installed at Pohang Light Source, a third generation synchrotron radiation facility in Pohang, Korea. The x-ray energy was set at 6.95 keV, and the x-ray beam was monochromatized by W/B4C monochromator. Condenser and objective zone plates were used as x-ray lenses. Zernike phase plate next to condenser zone plate was introduced for improved contrast imaging. The image of a sample was magnified 30 times by objective zone plate and 20 times by microscope objective, respectively. After additional 10 times digital magnification, the total magnifying power was up to 6000 times in the end. Phase contrast synchrotron images of 10-μm-thick female breast tissue of the normal, fibroadenoma, fibrocystic change and carcinoma cases were obtained. By phase contrast imaging, hard x-rays enable us to observe many structures of breast tissue without sample preparations such as staining or fixation

  17. Ameloglastic fibro-odontoma with a change of calcifying odontogenic cyst

    International Nuclear Information System (INIS)

    Kwon, Hyuk Rok; Han, Jin Woo; Lee, Jin Ho; Choi, Hang Moon; Park, In Woo; Lee, Suk Keun

    2001-01-01

    Thirteen-year-old girl complaining of the swelling and pain on the left midface visited our dental hospital. On the radiographic examination, well-defined radiolucent lesion with hyperostotic border was found in the left maxilla accompanying with the external root resorption of the involved teeth and the displaced second molar. CT showed calcified bodies, thinning of hard palate, inferior orbital wall and lateral wall of nasal fossa, and thinning and perforation of the buccal plate of the maxilla. Enucleation and curettage of the lesion and nasoantrostomy was carried out and histopathologic examination mainly showed a solid tumor tissue composed of odontogenic epithelium and pulp tissues admixed with dentin and enamel formation. And some part of reduced follicular epithelium of tooth germ showed a change mimicking calcifying odontogenic cyst. Taken together, we concluded the lesion is an ameloblastic fibro-odontoma with as change of calcifying odontogenic cyst

  18. Ameloglastic fibro-odontoma with a change of calcifying odontogenic cyst

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyuk Rok; Han, Jin Woo; Lee, Jin Ho; Choi, Hang Moon; Park, In Woo; Lee, Suk Keun [Kangnung National Univ., Kangnung (Korea, Republic of)

    2001-09-15

    Thirteen-year-old girl complaining of the swelling and pain on the left midface visited our dental hospital. On the radiographic examination, well-defined radiolucent lesion with hyperostotic border was found in the left maxilla accompanying with the external root resorption of the involved teeth and the displaced second molar. CT showed calcified bodies, thinning of hard palate, inferior orbital wall and lateral wall of nasal fossa, and thinning and perforation of the buccal plate of the maxilla. Enucleation and curettage of the lesion and nasoantrostomy was carried out and histopathologic examination mainly showed a solid tumor tissue composed of odontogenic epithelium and pulp tissues admixed with dentin and enamel formation. And some part of reduced follicular epithelium of tooth germ showed a change mimicking calcifying odontogenic cyst. Taken together, we concluded the lesion is an ameloblastic fibro-odontoma with as change of calcifying odontogenic cyst.

  19. Investigation of ultrashort-pulsed laser on dental hard tissue

    Science.gov (United States)

    Uchizono, Takeyuki; Awazu, Kunio; Igarashi, Akihiro; Kato, Junji; Hirai, Yoshito

    2007-02-01

    Ultrashort-pulsed laser (USPL) can ablate various materials with precious less thermal effect. In laser dentistry, to solve the problem that were the generation of crack and carbonized layer by irradiating with conventional laser such as Er:YAG and CO II laser, USPL has been studied to ablate dental hard tissues by several researchers. We investigated the effectiveness of ablation on dental hard tissues by USPL. In this study, Ti:sapphire laser as USPL was used. The laser parameter had the pulse duration of 130 fsec, 800nm wavelength, 1KHz of repetition rate and the average power density of 90~360W/cm2. Bovine root dentin plates and crown enamel plates were irradiated with USPL at 1mm/sec using moving stage. The irradiated samples were analyzed by SEM, EDX, FTIR and roughness meter. In all irradiated samples, the cavity margin and wall were sharp and steep, extremely. In irradiated dentin samples, the surface showed the opened dentin tubules and no smear layer. The Ca/P ratio by EDX measurement and the optical spectrum by FTIR measurement had no change on comparison irradiated samples and non-irradiated samples. These results confirmed that USPL could ablate dental hard tissue, precisely and non-thermally. In addition, the ablation depths of samples were 10μm, 20μm, and 60μm at 90 W/cm2, 180 W/cm2, and 360 W/cm2, approximately. Therefore, ablation depth by USPL depends on the average power density. USPL has the possibility that can control the precision and non-thermal ablation with depth direction by adjusting the irradiated average power density.

  20. Hard tissue compatibility of natural hydroxyapatite/chitosan composite

    International Nuclear Information System (INIS)

    Tang Xiaojun; Gui Lai; Lue Xiaoying

    2008-01-01

    The natural hydroxyapatite/chitosan (NHC) composite is a new synthesized material. The aim of this experiment was to assess the bone tissue compatibility of this NHC composite in vivo. Twenty-four healthy New Zealand rabbits were included in this study. Of those, 20 were used as the experimental group and four as the control group. In the experimental group, animals receive a cranium defect procedure and NHC composite repair. In the control group, animals underwent the cranium defect procedure without NHC composite repair. At 1, 4, 12, 24, and 40 weeks after surgery, the animals were sacrificed and samples were taken and assessed by gross observation, three-dimensional (3D) computerized tomographic (CT) reconstruction, histology and scanning electron microscope. Our results showed that at 1 week after repairing the bone defect with the NHC composite in the experimental group, new bone appeared around the composite and matured gradually. At 24 weeks after surgery, there were little collagenous tissues present between the material and surrounding bones. At 40 weeks after surgery, new bone had grown into the mature bone and total osseointegration had occurred. In the control group, however, no bone defect healing was observed at 40 weeks after surgery. All these results of the present in vivo work suggest that the NHC composite has a good hard tissue biocompatibility and an excellent osteoconductivity. It is suitable for artificial bone implants and frame materials of tissue engineering.

  1. Hard tissue compatibility of natural hydroxyapatite/chitosan composite

    Energy Technology Data Exchange (ETDEWEB)

    Tang Xiaojun; Gui Lai [Department of Cranio-maxillofacial Surgery, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, 33 Ba-Da-Chu Road, Beijing, 100144 (China); Lue Xiaoying [State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096 (China)], E-mail: laiguiplastic@tom.com, E-mail: luxy@seu.edu.cn

    2008-12-15

    The natural hydroxyapatite/chitosan (NHC) composite is a new synthesized material. The aim of this experiment was to assess the bone tissue compatibility of this NHC composite in vivo. Twenty-four healthy New Zealand rabbits were included in this study. Of those, 20 were used as the experimental group and four as the control group. In the experimental group, animals receive a cranium defect procedure and NHC composite repair. In the control group, animals underwent the cranium defect procedure without NHC composite repair. At 1, 4, 12, 24, and 40 weeks after surgery, the animals were sacrificed and samples were taken and assessed by gross observation, three-dimensional (3D) computerized tomographic (CT) reconstruction, histology and scanning electron microscope. Our results showed that at 1 week after repairing the bone defect with the NHC composite in the experimental group, new bone appeared around the composite and matured gradually. At 24 weeks after surgery, there were little collagenous tissues present between the material and surrounding bones. At 40 weeks after surgery, new bone had grown into the mature bone and total osseointegration had occurred. In the control group, however, no bone defect healing was observed at 40 weeks after surgery. All these results of the present in vivo work suggest that the NHC composite has a good hard tissue biocompatibility and an excellent osteoconductivity. It is suitable for artificial bone implants and frame materials of tissue engineering.

  2. Nonlinear scattering in hard tissue studied with ultrashort laser pulses

    International Nuclear Information System (INIS)

    Eichler, J.; Kim, B.M.

    2002-01-01

    The back-scattered spectrum of ultrashort laser pulses (800 nm, 0.2 ps) was studied in human dental and other hard tissues in vitro below the ablation threshold. Frequency doubled radiation (SHG), frequency tripled radiation and two-photon fluorescence were detected. The relative yield for these processes was measured for various pulse energies. The dependence of the SHG signal on probe thickness was determined in forward and back scattering geometry. SHG is sensitive to linear polarization of the incident laser radiation. SHG in human teeth was studied in vitro showing larger signals in dentin than in cementum and enamel. In carious areas no SHG signal could be detected. Possible applications of higher harmonic radiation for diagnostics and microscopy are discussed. (orig.)

  3. Dental hard tissue drilling by longitudinally excited CO2 laser

    Science.gov (United States)

    Uno, Kazuyuki; Yamamoto, Takuya; Akitsu, Tetsuya; Jitsuno, Takahisa

    2017-07-01

    We developed a longitudinally excited CO2 laser with a long optical cavity and investigated the drilling characteristics of dental hard tissue. The CO2 laser was very simple and consisted of a 45-cm-long alumina ceramic pipe with an inner diameter of 13 mm, a pulse power supply, a step-up transformer, a storage capacitance, a spark gap, and a long optical cavity with a cavity length of 175 cm. The CO2 laser produced a short pulse that had a spike pulse with the width of 337 ns and the energy of 1.9 mJ, a pulse tail with the length of 180 μs and the energy of 37.6 mJ, and a doughnut-like beam. In the investigation, a sample was a natural drying human tooth (enamel and dentine). In a processing system, a ZnSe focusing lens with the focal length of 50 mm was used and the location of the focal plane was that of the sample surface. In 1 pulse irradiation, the drilling characteristics depended on the fluence was investigated. In the enamel and dentin drilling, the drilling depth increased with the fluence. The 1 pulse irradiation with the fluence of 21.5 J/cm2 produced the depth of 79.3 μm in the enamel drilling, and the depth of 152.7 μm in the dentin drilling. The short-pulse CO2 laser produced a deeper drilling depth at a lower fluence than long-pulse CO2 lasers in dental hard tissue processing.

  4. The effect of hard tissue surgical changes on soft tissue displacement: a pilot CBCT study

    Directory of Open Access Journals (Sweden)

    Leonardo Koerich

    Full Text Available ABSTRACT Introduction: This pilot study had as main objective to test the reliability of a new method to evaluate orthognathic surgery outcomes and also, to understand the effect of hard tissue changes on soft tissue displacement. Methods: The sample consisted of eight patients that underwent bimaxillary advancement and had CBCT at two time points (before surgery and 6-8 months follow-up. Voxel-based cranial base superimposition was used to register the scans. A different technique of iterative closest point (ICP was used to measure and correlate the changes. The average displacement of 15 areas (4 hard tissue and 11 soft tissue were measured twice. Results: ICC was > 0.99 for all areas. Changes in the tip of the nose did not correlate with changes in any maxillary area, whereas soft tissue A point, A point and upper lips had correlation with several areas. The highest correlation for the maxilla was between the upper lip and the left/right supra cheilion (p< 0.001, r= 0.91 and p< 0.001, r= 0.93, respectively. In the mandible, the majority of the correlations involved soft tissue pogonion, pogonion and lower incisors, with the strongest one between pogonion and lower incisors (p< 0.001, r= 0.98. Conclusion: With the proper case selection, ICP is a reliable method that can be used to assess three-dimensional changes.

  5. Dental hard tissue characterization using laser-based ultrasonics

    Science.gov (United States)

    Blodgett, David W.; Massey, Ward L.

    2003-07-01

    Dental health care and research workers require a means of imaging the structures within teeth in vivo. One critical need is the detection of tooth decay in its early stages. If decay can be detected early enough, the process can be monitored and interventional procedures, such as fluoride washes and controlled diet, can be initiated to help re-mineralize the tooth. Currently employed x-ray imaging is limited in its ability to visualize interfaces and incapable of detecting decay at a stage early enough to avoid invasive cavity preparation followed by a restoration. To this end, non-destructive and non-contact in vitro measurements on extracted human molars using laser-based ultrasonics are presented. Broadband ultrasonic waves are excited in the extracted sections by using a pulsed carbon-dioxide (CO2) laser operating in a region of high optical absorption in the dental hard tissues. Optical interferometric detection of the ultrasonic wave surface displacements in accomplished with a path-stabilized Michelson-type interferometer. Results for bulk and surface in-vitro characterization of caries are presented on extracted molars with pre-existing caries.

  6. Lasers in Esthetic Dentistry: Soft Tissue Photobiomodulation, Hard Tissue Decontamination, and Ceramics Conditioning

    Directory of Open Access Journals (Sweden)

    Karen Müller Ramalho

    2014-01-01

    Full Text Available The increasing concern and the search for conservative dental treatments have resulted in the development of several new technologies. Low and high power lasers can be cited as one of these new technologies. Low power lasers act at cellular level leading to pain reduction, modulation of inflammation, and improvement of tissue healing. High power lasers act by increasing temperature and have the potential to promote microbial reduction and ablation of hard and soft tissues. The clinical application of both low and high power lasers requires specific knowledge concerning laser interaction with biological tissues, so that the correct irradiation protocol can be established. The present case report describes the clinical steps of two metal-ceramic crowns development in a 60-year-old patient. Three different laser wavelengths were applied throughout the treatment with different purposes: Nd:YAG laser (1,064 nm for dentin decontamination, diode (660 nm for soft tissue biomodulation, and Er:YAG laser (2,940 nm for inner ceramic surface conditioning. Lasers were successfully applied in the present case report as coadjutant in the treatment. This coadjutant technology can be a potential tool to assist treatment to reach the final success.

  7. The method of diagnosis and classification of the gingival line defects of the teeth hard tissues

    Directory of Open Access Journals (Sweden)

    Olena Bulbuk

    2017-06-01

    Full Text Available For solving the problem of diagnosis and treatment of hard tissue defects the significant role belongs to the choice of tactics for dental treatment of hard tissue defects located in the gingival line of any tooth. This work aims to study the problems of diagnosis and classification of gingival line defects of the teeth hard tissues. That will contribute to the objectification of differentiated diagnostic and therapeutic approaches in the dental treatment of various clinical variants of these defects localization. The objective of the study – is to develop the anatomical-functional classification for differentiated estimation of hard tissue defects in the gingival part, as the basis for the application of differential diagnostic-therapeutic approaches to the dental treatment of hard tissue defects disposed in the gingival part of any tooth. Materials and methods of investigation: There was conducted the examination of 48 patients with hard tissue defects located in the gingival part of any tooth. To assess the magnitude of gingival line destruction the periodontal probe and X-ray examination were used. Results. The result of the performed research the classification of the gingival line defects of the hard tissues was offered using exponent power. The value of this indicator is equal to an integer number expressed in millimeters of distance from the epithelial attachment to the cavity’s bottom of defect. Conclusions. The proposed classification fills an obvious gap in academic representations about hard tissue defects located in the gingival part of any tooth. Also it offers the prospects of consensus on differentiated diagnostic-therapeutic approaches in different clinical variants of location.  This classification builds methodological “bridge of continuity” between therapeutic and prosthetic dentistry in the field of treatment of the gingival line defects of dental hard tissues.

  8. Heat generation caused by ablation of dental hard tissues with an ultrashort pulse laser (USPL) system.

    Science.gov (United States)

    Braun, Andreas; Krillke, Raphael Franz; Frentzen, Matthias; Bourauel, Christoph; Stark, Helmut; Schelle, Florian

    2015-02-01

    Heat generation during the removal of dental hard tissues may lead to a temperature increase and cause painful sensations or damage dental tissues. The aim of this study was to assess heat generation in dental hard tissues following laser ablation using an ultrashort pulse laser (USPL) system. A total of 85 specimens of dental hard tissues were used, comprising 45 specimens of human dentine evaluating a thickness of 1, 2, and 3 mm (15 samples each) and 40 specimens of human enamel with a thickness of 1 and 2 mm (20 samples each). Ablation was performed with an Nd:YVO4 laser at 1,064 nm, a pulse duration of 9 ps, and a repetition rate of 500 kHz with an average output power of 6 W. Specimens were irradiated for 0.8 s. Employing a scanner system, rectangular cavities of 1-mm edge length were generated. A temperature sensor was placed at the back of the specimens, recording the temperature during the ablation process. All measurements were made employing a heat-conductive paste without any additional cooling or spray. Heat generation during laser ablation depended on the dental hard tissue (enamel or dentine) and the thickness of the respective tissue (p dental hard tissues, heat generation has to be considered. Especially during laser ablation next to pulpal tissues, painful sensations and potential thermal injury of pulp tissue might occur.

  9. Calcium and magnesium content in hard tissues of rats under condition of subchronic lead intoxication.

    Science.gov (United States)

    Todorovic, Tatjana; Vujanovic, Dragana; Dozic, Ivan; Petkovic-Curcin, Aleksandra

    2008-03-01

    Lead manifests toxic effects in almost all organs and tissues, especially in: the nervous system, hematopoietic system, kidney and liver. This metal has a special affinity for deposition in hard tissue, i.e., bones and teeth. It is generally believed that the main mechanism of its toxicity relies on its interaction with bioelements, especially with Ca and Mg. This article analyses the influence of Pb poisoning on Ca and Mg content in hard tissues, (mandible, femur, teeth and skull) of female and young rats. Experiments were carried out on 60 female rats, AO breed, and on 80 of their young rats (offspring). Female rats were divided into three groups: the first one was a control group, the second one received 100 mg/kg Pb2+ kg b.wt. per day in drinking water, the third one received 30 mg/kg Pb(2+) kg b.wt. per day in drinking water. Young rats (offspring) were divided into the same respective three groups. Lead, calcium and magnesium content in hard tissues (mandible, femur, teeth-incisors and skull) was determined by flame atomic absorption spectrophotometry in mineralized samples. There was a statistically significant Pb deposition in all analyzed female and young rat hard tissues. Ca and Mg contents were significantly reduced in all female and young rat hard tissues. These results show that Pb poisoning causes a significant reduction in Ca and Mg content in animal hard tissues, which is probably the consequence of competitive antagonism between Pb and Ca and Mg.

  10. Hard and soft tissue correlations in facial profiles: a canonical correlation study

    Directory of Open Access Journals (Sweden)

    Shamlan MA

    2015-01-01

    Full Text Available Manal A Shamlan,1 Abdullah M Aldrees2 1Faculty of Dentistry, King Abdulaziz University, Jeddah, 2Division of Orthodontics, Department of Pediatric Dentistry and Orthodontics, College of Dentistry, King Saud University, Riyadh, Saudi Arabia Background: The purpose of this study was to analyze the relationship between facial hard and soft tissues in normal Saudi individuals by studying the canonical correlation between specific hard tissue landmarks and their corresponding soft tissue landmarks. Methods: A retrospective, cross-sectional study was designed, with a sample size of 60 Saudi adults (30 males and 30 females who had a class I skeletal and dental relationship and normal occlusion. Lateral cephalometric radiographs of the study sample were investigated using a series of 29 linear and angular measurements of hard and soft tissue features. The measurements were calculated electronically using Dolphin® software, and the data were analyzed using canonical correlation. Results: Eighty-four percent of the variation in the soft tissue was explained by the variation in hard tissue. Conclusion: The position of the upper and lower incisors and inclination of the lower incisors influence upper lip length and lower lip position. The inclination of the upper incisors is associated with lower lip length. Keywords: facial profile, hard tissue, soft tissue, canonical correlation

  11. Water hardness and cardiovascular disease. Elements in water and human tissues

    Energy Technology Data Exchange (ETDEWEB)

    Sharrett, A R

    1977-05-01

    The hypothesis that the hardness of drinking water has a causal role in the development of cardiovascular disease will be strengthened if it can be demonstrated that elements in drinking water find their way into human tissues in significant amounts. For biologically important metals, the evidence is reviewed for a relationship of tissue levels to levels in drinking water. Hard water can contribute significantly to daily magnesium intake. Residents of hard-water areas may have raised levels of magnesium in coronary arteries, bone, and myocardial tissue. Lead levels in bone and in blood have been shown to be elevated in individuals living in homes with lead plumbing and soft water. Cadmium intake from water is probably small compared to that from other sources, and there is no convincing evidence of alteration in human tissue levels via drinking water cadmium. Human zinc and copper tissue levels are of interest but have not been adequately studied in relation to drinking water levels.

  12. Calcified adrenal cyst

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chung Kyu; Choi, Byung Sook [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1970-10-15

    Calcified hemorrhagic adrenal cysts are rather rare and unusual pathologic entity. Especially, the peripheral curvilinear calcification on roentgenogram is fairly characteristic picture of the cysts. Recently, we have experienced in Severance Hospital one of the classical cases of the benign calcified adrenal cyst in 35 year old white mail patient who has had vague abdominal pain and palpable mass in right abdomen. It has been reviewed several reports for adrenal cysts and hoped that this report may call additional attention of radiological diagnosis on this unusual disease.

  13. Gastric Calcifying Fibrous Tumour

    Directory of Open Access Journals (Sweden)

    Tan Attila

    2006-01-01

    Full Text Available Intramucosal gastric tumours are most commonly found to be gastrointestinal stromal tumours or leiomyomas (smooth muscle tumours; however, a variety of other uncommon mesenchymal tumours can occur in the stomach wall. A rare benign calcifying fibrous tumour is reported and the endoscopic appearance, ultrasound findings and morphology are documented. A review of the literature found only two similar cases.

  14. Photoacoustic imaging in both soft and hard biological tissue

    International Nuclear Information System (INIS)

    Li, T; Dewhurst, R J

    2010-01-01

    To date, most Photoacoustic (PA) imaging results have been from soft biotissues. In this study, a PA imaging system with a near-infrared pulsed laser source has been applied to obtain 2-D and 3-D images from both soft tissue and post-mortem dental samples. Imaging results showed that the PA technique has the potential to image human oral disease, such as early-stage teeth decay. For non-invasive photoacoustic imaging, the induced temperature and pressure rises within biotissues should not cause physical damage to the tissue. Several simulations based on the thermoelastic effect have been applied to predict initial temperature and pressure fields within a tooth sample. Predicted initial temperature and pressure rises are below corresponding safety limits.

  15. The CuHBr laser in hard dental tissues

    International Nuclear Information System (INIS)

    Miyakawa, Walter

    2004-01-01

    In this work, it was verified the viability of characterization of laser-irradiated dental tissues in two extreme conditions: high and low absorption by the dental tissue. Comparison with light microscopy and scanning electronic microscopy revealed that these techniques are complementary each other: quantitative topographic information is directly extracted from the atomic force microscopy, while morphological aspects can be imaged by light microscopy or scanning electronic microscopy. A cavity generated by Cu-HyBrID laser in human dental enamel was also evaluated by atomic force microscopy. Structural and morphological differences between the fused and resolidified enamel from the cavity walls and the enamel from the natural tis sue were analyzed. A model, based on the Monte Carlo method described the propagation of CuHBr laser radiation and the absorbed energy distribution in dental tissues. Experimental measures with a CCD camera were used to semiquantitatively characterize the scattered light distribution in the tooth and they corroborated the model. It was observed that Rayleigh scattering and diffuse scattered radiation is predominant. The absorbed energy distribution map and the temperature variation along the beam propagation axis presented strong dependence with the absorption coefficient of the dental enamel and they cannot be deduced from the light distribution profile. The exposure time threshold for dental enamel melting and evaporation, irradiated by a specific condition of the green line of the Cu-HyBrID laser, was determined and a phenomenological model was discussed for the laser-matter interaction, based on pulse accumulation effect. Theoretical temperature calculations associated with experimental evidences strongly suggest that optical and thermal parameters should vary with temperature. The obtained exposure time threshold should correspond to the time necessary to the sample reach the critical temperature, at which the increase of absorption

  16. Hard tissue deposition in dental pulp canal by {alpha}-tricalcium phosphate cement

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, M.; Toda, T. [Osaka Dental Univ. (Japan). Dept. of Endodontics; Mandai, Y. [Bio-Chemical Lab. of Nitta Gelatin Inc., Yao (Japan); Oonishi, H. [Osaka Minami National Hospital, Kawachi (Japan). Dept. of Orthopaedic Surgery

    2001-07-01

    Canal closure by hard tissue proliferation in the pulp canal and/or apical foramen is the most ideal healing after pulp removal. Generally, Ca(OH){sub 2} may induce secondary dentine or dentine-bridge on the amputated pulp surface. However, Ca(OH){sub 2} shows strong alkalinity and may cause severe inflammatory responses in the residual pulp. Moreover, completely formed dentine-bridge at the orifice will disturb further treatment of residual pulp because of the difficulty in localizing the pathway. The purpose of this study was to see hard tissue induction using newly developed {alpha}-tricalcium phosphate cement and to recognize the morphological difference of hard tissue from that of Ca(OH){sub 2}. (orig.)

  17. Hard tissue regeneration using bone substitutes: an update on innovations in materials.

    Science.gov (United States)

    Sarkar, Swapan Kumar; Lee, Byong Taek

    2015-05-01

    Bone is a unique organ composed of mineralized hard tissue, unlike any other body part. The unique manner in which bone can constantly undergo self-remodeling has created interesting clinical approaches to the healing of damaged bone. Healing of large bone defects is achieved using implant materials that gradually integrate with the body after healing is completed. Such strategies require a multidisciplinary approach by material scientists, biological scientists, and clinicians. Development of materials for bone healing and exploration of the interactions thereof with the body are active research areas. In this review, we explore ongoing developments in the creation of materials for regenerating hard tissues.

  18. Comparison of soft and hard tissue ablation with sub-ps and ns pulse lasers

    Energy Technology Data Exchange (ETDEWEB)

    Da Silva, L.B.; Stuart, B.C.; Celliers, P.M.; Feit, M.D.; Glinsky, M.E.; Heredia, N.J.; Herman, S.; Lane, S.M.; London, R.A.; Matthews, D.L.; Perry, M.D.; Rubenchik, A.M. [Lawrence Livermore National Lab., CA (United States); Chang, T.D. [Veterans Administration Hospital, Martinez, CA (United States); Neev, J. [Beckman Laser Inst. and Medical Clinic, Irvine, CA (United States)

    1996-05-01

    Tissue ablation with ultrashort laser pulses offers several unique advantages. The nonlinear energy deposition is insensitive to tissue type, allowing this tool to be used for soft and hard tissue ablation. The localized energy deposition lead to precise ablation depth and minimal collateral damage. This paper reports on efforts to study and demonstrate tissue ablation using an ultrashort pulse laser. Ablation efficiency and extent of collateral damage for 0.3 ps and 1000 ps duration laser pulses are compared. Temperature measurements of the rear surface of a tooth section is also presented.

  19. Evaluation of the linearity of soft- to hard-tissue movement after orthognathic surgery

    NARCIS (Netherlands)

    Chew, Ming Tak; Sandham, John; Wong, Hwee Bee

    2008-01-01

    Introduction: Our aim in this study was to investigate whether a linear relationship exists between soft- to hard-tissue changes for both maxillary and mandibular landmarks over a wide range of skeletal changes. Methods: The sample consisted of 30 Chinese patients with Class III malocclusion treated

  20. Hard tissue formation of STRO-1-selected rat dental pulp stem cells in vivo.

    NARCIS (Netherlands)

    Yang, X.; Walboomers, X.F.; Beucken, J.J.J.P van den; Bian, Z.; Fan, M.; Jansen, J.A.

    2009-01-01

    The objective of this study was to examine hard tissue formation of STRO-1-selected rat dental pulp-derived stem cells, seeded into a calcium phosphate ceramic scaffold, and implanted subcutaneously in mice. Previously, STRO-1 selection was used to obtain a mesenchymal stem cell progenitor

  1. Evaluation of the linearity of soft- to hard-tissue movement after orthognathic surgery

    NARCIS (Netherlands)

    Chew, Ming Tak; Sandham, John; Wong, Hwee Bee

    Introduction: Our aim in this study was to investigate whether a linear relationship exists between soft- to hard-tissue changes for both maxillary and mandibular landmarks over a wide range of skeletal changes. Methods: The sample consisted of 30 Chinese patients with Class III malocclusion treated

  2. A study to evaluate cephalometric hard tissue profile of Tamil population for orthognathic surgery.

    Science.gov (United States)

    Nachiappan, S; Tharanikumar, S; Chandran, Ajay; Anusudha, P; Nandini, G D; Balasubramaniam, Murali

    2015-08-01

    The primary aim of this study is to compare, the cephalometric hard tissue profile values and analysis between Tamil and Caucasian population. The study also aims to create a better understanding in the facial proportions of Tamil Nadu population and to have better diagnosis and treatment planning for orthognathic surgery for Tamil population in Tamil Nadu.

  3. X-Ray pictures of the developmental anomalis of the hard dental tissue

    International Nuclear Information System (INIS)

    Cecetkova, A.; Ondrasovicova, J.

    2008-01-01

    Dental anomalies are rare lessions of the hard dental tissue. They are as symptoms varies of the syndromes. They are as follow: hyperdoncia, hypodoncia, oligodoncia, anodoncia, mesiodens, macrodoncia and microdoncia. All of the above anomalis are detected by X-ray diagnostics ( intraoral and extra-oral radiography ). (authors)

  4. Multiple calcifying hyperplastic dental follicles: A case report

    International Nuclear Information System (INIS)

    Aydin, Ulkem; Baykul, Timucin; Yildirim, Benay; Yildirim, Derya; Bozdemir, Esin; Karaduman, Ayse

    2013-01-01

    This report describes a 31-year-old female patient with six impacted teeth. The crowns of the impacted teeth were surrounded with cyst-like lesions with a mixed internal structure and well-defined cortical borders. Microscopic examination of the specimen obtained from the follicle of the left mandibular third molar tooth revealed loose to moderately dense collagenous connective tissue with abundant calcified material and sparse epithelial islands. A diagnosis of multiple calcifying hyperplastic dental follicles was made.

  5. Multiple calcifying hyperplastic dental follicles: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Aydin, Ulkem [Dept. of Dentomaxillofacial Radiology, Baskent University Faculty of Dentistry, Ankara (Turkey); Baykul, Timucin [Dept. of Oral and Maxillofacial Surgery, Suleyman Demirel University Faculty of Dentistry, Isparta (Turkey); Yildirim, Benay [Dept. of Oral Pathology, Gazi University Faculty of Dentistry, Ankara (Turkey); Yildirim, Derya; Bozdemir, Esin [Dept. of Dentomaxillofacial Radiology, Suleyman Demirel University Faculty of Dentistry, Isparta (Turkey); Karaduman, Ayse [Atlas Dent Dental Health Center, Aydin (Turkey)

    2013-12-15

    This report describes a 31-year-old female patient with six impacted teeth. The crowns of the impacted teeth were surrounded with cyst-like lesions with a mixed internal structure and well-defined cortical borders. Microscopic examination of the specimen obtained from the follicle of the left mandibular third molar tooth revealed loose to moderately dense collagenous connective tissue with abundant calcified material and sparse epithelial islands. A diagnosis of multiple calcifying hyperplastic dental follicles was made.

  6. Environmental lead pollution and its possible influence on tooth loss and hard dental tissue lesions.

    Science.gov (United States)

    Cenić-Milosević, Desanka; Mileusnić, Ivan; Kolak, Veljko; Pejanović, Djordje; Ristić, Tamara; Jakovljević, Ankica; Popović, Milica; Pesić, Dragana; Melih, Irena

    2013-08-01

    Environmental lead (Pb) pollution is a global problem. Hard dental tissue is capable of accumulating lead and other hard metals from the environment. The aim of this study was to investigate any correlation between the concentration of lead in teeth extracted from inhabitants of Pancevo and Belgrade, Serbia, belonging to different age groups and occurrence of tooth loss, caries and non-carious lesions. A total of 160 volunteers were chosen consecutively from Pancevo (the experimental group) and Belgrade (the control group) and divided into 5 age subgroups of 32 subjects each. Clinical examination consisted of caries and hard dental tissue diagnostics. The Decayed Missing Filled Teeth (DMFT) Index and Significant Caries Index were calculated. Extracted teeth were freed of any organic residue by UV digestion and subjected to voltammetric analysis for the content of lead. The average DMFT scores in Pancevo (20.41) were higher than in Belgrade (16.52); in the patients aged 31-40 and 41-50 years the difference was significant (p lead concentration and the number of extracted teeth, number of carious lesions and non-carious lesions found in the patients living in Pancevo, one possible cause of tooth loss and hard dental tissue damage could be a long-term environmental exposure to lead.

  7. Odonto calcifying cyst

    Directory of Open Access Journals (Sweden)

    Nalini Aswath

    2013-01-01

    Full Text Available The calcifying odontogenic cyst (COC is reported to be associated with odontoma in 24% of cases. Separation of the cases of calcifying odontogenic cyst associated with odontoma (COCaO may lead to a better understanding of the pathogenesis of this lesion. The literature revealed 52 cases of COCaO. The male to female ratio was 1:1.9, with a mean age of 16 years. Most common location was the maxilla (61.5%. The radiographic appearance of most cases (80.5% was a well-defined, mixed radiolucent-radiopaque lesion. Histologically, the lesions consisted of a single large cyst with tooth-like structures as an integral part, giving the impression of a single lesion. In addition to the unique histologic features, differences in gender and distribution were found between the cases of COCaO and those of simple COC. COCaO may be regarded as a separate entity and classified as a benign, mixed odontogenic tumor. The term odontocalcifying odontogenic cyst is suggested.

  8. Odonto calcifying cyst.

    Science.gov (United States)

    Aswath, Nalini; Mastan, Kader; Manikandan, Tirupathi; Samuel, Gigi

    2013-01-01

    The calcifying odontogenic cyst (COC) is reported to be associated with odontoma in 24% of cases. Separation of the cases of calcifying odontogenic cyst associated with odontoma (COCaO) may lead to a better understanding of the pathogenesis of this lesion. The literature revealed 52 cases of COCaO. The male to female ratio was 1:1.9, with a mean age of 16 years. Most common location was the maxilla (61.5%). The radiographic appearance of most cases (80.5%) was a well-defined, mixed radiolucent-radiopaque lesion. Histologically, the lesions consisted of a single large cyst with tooth-like structures as an integral part, giving the impression of a single lesion. In addition to the unique histologic features, differences in gender and distribution were found between the cases of COCaO and those of simple COC. COCaO may be regarded as a separate entity and classified as a benign, mixed odontogenic tumor. The term odontocalcifying odontogenic cyst is suggested.

  9. Detection of free radicals in γ-irradiated seasnail hard tissues by electron paramagnetic resonance

    International Nuclear Information System (INIS)

    Koeseoglu, Rahmi; Koeksal, Fevzi

    2003-01-01

    Gamma-irradiated seasnail (from family of Helix lukortium) hard tissues (CaCO 3 ) were investigated by electron paramagnetic resonance (EPR) at room temperature. The radicals produced by γ-irradiation in seasnail were attributed to orthorhombic C · O 2 - , freely rotating C · O 2 - , orthorhombic C · O 3 - , axial C · O 3 - , and axial C · O 3 3- free radicals. Unirradiated seasnail hard tissues also feature Mn 2+ ions in their EPR spectra. The hyperfine values were determined for the 13 C nucleus in the orthorhombic C · O 2 - and axial C · O 3 3- free radicals and for the manganese impurity ions. The g values of all the free radicals have been measured. The results were compared with the literature data for similar defects

  10. Detection for demineralization of dental hard tissues using index-sequenced radiographs

    International Nuclear Information System (INIS)

    Park, Dong Hyun; Park, Young Ho; Kim, Kyung Sook; Park, Jeong Hoon; Lee, Gi Ja; Choi, Sam Jin; Park, Hun Kuk; Choi, Yong Suk; Hwang, Eui Hwan

    2009-01-01

    The purpose of this study was to develop the radiographic technique for detecting the demineralization which is known as indication of dental caries. This technique was based on the comparing of multiple radiographs which was irradiated by multiple X-ray spectra. For the meaningful comparing, the multiple radiographs were reconstructed to the dosimetrically consistent images using a standard material. The difference of resulting images of same target with multiple spectra represents the difference of response of material as regards the spectra. We have found about 10% of demineralization of dental hard tissues particularly in the proximal region through the analyzing of differences. Most intriguing thing in this investigation was that the method to analyze difference shows us to an anatomic structure of dental hard tissues even if absolute values of optical density were excluded during the procedures.

  11. Relative growth pattern and hard tissue of vertebral centra by microradiography of bluefin tuna

    International Nuclear Information System (INIS)

    Kubo, Y.; Asano, H.

    1989-01-01

    To clarify the growth feature and the structure of hard tissue, we studied the vertebral centrum of three species, bluefin tuna Thunnus thynnus, bigeye tuna T. obesus and skipjack Katsuwonus pelamis (BL: 44.2, 39.5 and 40.0cm respectively). We examined the ratio of cetrum length to diameter in each vertebral centrum and obtained the value of 0.9-1.3 in most centra among three species. This indicates that the examined species belong to the equivalent type of the relative growth pattern of vertebral centra. The hard tissue was observed by microradiography, with the longitudinal and cross sections (about 100 μm) cut through the center of notochordal pore. The major centra of the vertebral column were composed of characteristic simple structure like a cross, when seen in the microradiographs of cross sections. Microradiographs indicated that the bone has complicated canals with minute spaces like the bone cavities

  12. Detection for demineralization of dental hard tissues using index-sequenced radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Park, Dong Hyun; Park, Young Ho; Kim, Kyung Sook; Park, Jeong Hoon; Lee, Gi Ja; Choi, Sam Jin; Park, Hun Kuk [Department of Biomedical Engineering, School of Medicine, KyungHee University, Seoul (Korea, Republic of); Choi, Yong Suk; Hwang, Eui Hwan [Department of Oral and Maxillofacial Radiology, Institute of Oral Biology, School of Dentistry, KyungHee University, Seoul (Korea, Republic of)

    2009-06-15

    The purpose of this study was to develop the radiographic technique for detecting the demineralization which is known as indication of dental caries. This technique was based on the comparing of multiple radiographs which was irradiated by multiple X-ray spectra. For the meaningful comparing, the multiple radiographs were reconstructed to the dosimetrically consistent images using a standard material. The difference of resulting images of same target with multiple spectra represents the difference of response of material as regards the spectra. We have found about 10% of demineralization of dental hard tissues particularly in the proximal region through the analyzing of differences. Most intriguing thing in this investigation was that the method to analyze difference shows us to an anatomic structure of dental hard tissues even if absolute values of optical density were excluded during the procedures.

  13. Different manifestations of calcifying cystic odontogenic tumor

    Directory of Open Access Journals (Sweden)

    Estevam Rubens Utumi

    2012-09-01

    Full Text Available The calcifying cystic odontogenic tumor normally presents as apainless, slow-growing mass, involving both maxilla and mandible,primarily the anterior segment (incisor/canine area. It generallyaffects young adults in the third to fourth decades, with no genderpredilection. Computerized tomography images revealed importantcharacteristics that were not detected by panoramic radiography,such as fenestration, calcification and tooth-like structures. Thetypical microscopic feature of this lesion is the presence of variableamounts of aberrant epithelial cells, without nuclei, which arenamed “ghost cells”. In addition, dysplastic dentine can be foundand occasionally the cyst can be associated with an area of dentalhard tissue formation resembling an odontoma. The treatment forcalcifying cystic odontogenic tumor involves simple enucleationand curettage. The purpose of this article is to present two differentmanifestation of calcifying cystic odontogenic tumor in whichcomputerized tomography, associated to clinical features, servedas an important tool for diagnosis, adequate surgical planning andfollow-up of patients.

  14. Analysis of enamel microhardness at various hard tissue states and depth of the microfissures

    Directory of Open Access Journals (Sweden)

    S. P. Yarova

    2013-08-01

    Full Text Available In clinical practice are often diagnosed precervical lesions: wedge-shaped defects and cracks. Long phases of the confrontation of the body as a damaging influence in the formation of thicker tissue sections of higher salinity, density and sustainability occur prior to the integrity of the enamel. Micro-hardness is one of the important characteristics of the micro-mechanical strength of the tooth-related physical and chemical changes that occur in the enamel as a result of external and internal influences. The purpose of the study was to identify possible differences in the micro-hardness of enamel, depending on the depth of fissures and pathology of hard tissues of the teeth. We investigated the longitudinal sections of 27 teeth (18 - intact, 5 - with wedge-shaped defect, 4 - with cervical caries of both jaws removed for clinical indications in patients aged 25-54 years, who were diagnosed three types of fractures (SB Ivanov, 1984. Hardness was determined in the outer, middle, inner layers of enamel in three topographical locations: in the cusp tip (cutting edge of the tooth equator and neck as in previously described technique (S. Remizov, 1965. The obtained results showed decrease in strength with micro-cracks enamel, compared with apparently intact ones, on the average 10% more in the incisal areas (tuber, less - in the equatorial zone. In intact teeth with micro-cracks and having a wedge-shaped defect the indices differed significantly depending on the depth of the defects of the cutting edge (tuber and the equator: they were the smallest in the deep type III micro-cracks (p <0.05. The opposite picture was observed in samples with cervical caries. Thus, the statistically significant difference in terms of the micro-hardness of the enamel, depending on the depth of defects has been identified only in the area of cutting edge (tuber: in samples with deep micro-cracks of enamel type III they were the highest (P = 0.017. The greatest values of

  15. The influence of parotid gland sparing on radiation damages of dental hard tissues.

    Science.gov (United States)

    Hey, Jeremias; Seidel, Johannes; Schweyen, Ramona; Paelecke-Habermann, Yvonne; Vordermark, Dirk; Gernhardt, Christian; Kuhnt, Thomas

    2013-07-01

    The aim of the present study was to evaluate whether radiation damage on dental hard tissue depends on the mean irradiation dose the spared parotid gland is subjected to or on stimulated whole salivary flow rate. Between June 2002 and October 2008, 70 patients with neck and cancer curatively irradiated were included in this study. All patients underwent dental treatment referring to the guidelines and recommendations of the German Society of Dental, Oral and Craniomandibular Sciences prior, during, and after radiotherapy (RT). During the follow-up period of 24 months, damages on dental hard tissues were classified according to the RTOG/EORTC guidelines. The mean doses (D(mean)) during spared parotid gland RT were determined. Stimulated whole saliva secretion flow rates (SFR) were measured before RT and 1, 6, 12, 24 months after RT. Thirty patients showed no carious lesions (group A), 18 patients developed sporadic carious lesions (group B), and 22 patients developed general carious lesions (group C). Group A patients received a D mean of 21.2 ± 11.04 Gy. Group B patients received a D(mean) of 26.5 ± 11.59 Gy and group C patients received a D(mean) of 33.9 ± 9.93 Gy, respectively. The D(mean) of group A was significantly lower than the D(mean) of group C (p dental hard tissue correlates with increased mean irradiation doses as well as decreased salivary flow rates. Parotid gland sparing resulting in a dose below 20 Gy reduces radiation damage on dental hard tissues, and therefore, the dose may act as a predictor for the damage to be expected.

  16. Biologically Active Polycaprolactone/Titanium Hybrid Electrospun Nanofibers for Hard Tissue Engineering

    DEFF Research Database (Denmark)

    Barakat, Nasser A. M.; Sheikh, Faheem A.; Al-Deyab, Salem S.

    2011-01-01

    In this study, a novel strategy to improve the bioactivity of polycaprolactone nanofibers is proposed. Incorporation of pure titanium nanoparticles into polycaprolactone nanofibers strongly enhances the precipitation of bone-like apatite materials when the doped nanofibers are soaked in a simulat...... nanofiber mats and the successful incorporation of the titanium nanoparticles make the prepared polycaprolactone nanofiber mat a proper candidate for the hard-tissue engineering applications....

  17. Histological observation on dental hard tissue irradiated by ultrashort-pulsed laser

    Science.gov (United States)

    Uchizono, Takeyuki; Awazu, Kunio; Igarashi, Akihiro; Kato, Junji; Hirai, Yoshito

    2006-04-01

    In the field of dentistry, effectiveness of USPL irradiation is researched because USPL has less thermal side effect to dental hard tissue. In this paper, we observed morphological change and optical change of dental hard tissue irradiated by USPL for discussing the safety and effectiveness of USPL irradiation to dental hard tissues. Irradiated samples were crown enamel and root dentin of bovine teeth. Lasers were Ti:sapphire laser, which had pulse duration (P d)of 130 fsec and pulse repetition rate (f) of 1kHz and wavelength (l) of 800nm, free electron laser (FEL), which had P d of 15 μsec and f of 10Hz and wavelength of 9.6μm, and Er:YAG laser, which had P d of 250 μsec and f of 10Hz and wavelength of 2.94μm. After laser irradiation, the sample surfaces and cross sections were examined with SEM and EDX. The optical change of samples was observed using FTIR. In SEM, the samples irradiated by USPL had sharp and accurate ablation with no crack and no carbonization. But, in FEL and Er:YAG laser, the samples has rough ablation with crack and carbonization. It was cleared that the P/Ca ratio of samples irradiated by USPL had same value as non-irradiated samples. There was no change in the IR absorption spectrum between samples irradiated by USPL and non-irradiated sample. But, they of samples irradiated by FEL and Er:YAG laser, however, had difference value as non-irradiated samples. These results showed that USPL might be effective to ablate dental hard tissue without thermal damage.

  18. Soft and Hard Tissue Management in Implant Therapy—Part I: Surgical Concepts

    Directory of Open Access Journals (Sweden)

    Antonio D'Addona

    2012-01-01

    Full Text Available Implant therapy has become a reliable and predictable treatment alternative for the replacement of missing teeth with conventional removable and fixed partial dentures. Recently though, in the pursuit for improved esthetics, the literature has dedicated a considerable amount of its research on the successful maintenance and regeneration of the surrounding gingiva and bone, which are lost following extraction of a tooth. Thoroughly analyzing the anatomic situation and well-planned treatment has become a requirement, because incorrectly planned and positioned implants may jeopardize long-term esthetic and functional prognosis. In addition, many types of biocompatible materials, autogenous hard and soft tissue grafts, and different surgical techniques have been developed, and their viability has been investigated. As a result, implant specialists have gained a greater understanding of the dynamics and anatomical and biological concepts of the periodontium and peri-implant tissues both at the surgical and prosthetic phases of treatment, which contributes to better soft and hard tissue management (SHTM. This may further contribute to achieving a superior final result which is obtained by having a harmonious soft tissue profile, a correctly placed and contoured final restoration, and the reestablishment of masticatory function and phonetics.

  19. Calcified fibrous pseudotumor of spermatic cord

    International Nuclear Information System (INIS)

    Rodriguez Collar, Tomas Lazaro; Valdes Estevez, Brasily; Nagua Valencia, Miguel Angel; Salinas Olivares, Mercedes Rita

    2009-01-01

    Paratesticular tumors are infrequent and most are benigns. This a case presentation of a patient aged 24 with a history of good health coming to our consultation by presence of a hard and painless 4 cm tumor in right scrotum with a 6 months course. Scrotal ultrasound (US) showed a well circumscribed heterogeneous lesion separate of epididymis and the testis. Fine needle aspiration biopsy (FNAB) was not possible by hardness of tumor. A inguinal surgery was performed and the total tumor exeresis using freezing biopsy negative of malignancy. Final histopathological report was: calcified fibrous pseudotumor of spermatic cord. Patient's course has been satisfactory. Significance of inguinal surgery was confirmed for the paratesticular tumor approach, even more when FNAB it is not conclusive for diagnosis.(author)

  20. Interaction of a pulsed alexandrite laser with hard and soft biological tissue

    Science.gov (United States)

    Paterson, Lorna M.; Dickinson, Mark R.; King, Terence A.; Watts, David C.

    1994-02-01

    An alexandrite laser has been used in the fixed-Q and Q-switched modes, at the fundamental and frequency doubled wavelengths on a selection of hard and soft tissue. In an investigation into the potential use of the laser for the removal of deep lying lesions such as cutaneous vascular lesions and tatoos, studies have been carried out to characterize the depth and extent of the laser/tissue interaction in samples of tissue which greatly absorb the 750 nm radiation. The interaction of the laser radiation with extracted teeth was investigated looking at healthy enamel and dentine, and caries. Surface profile measurements of the enamel and dentine before and after irradiation show little physical effect of the laser irradiation, whereas caries appear to be ablated.

  1. Estimation of soft- and hard-tissue thickness at implant sites

    Directory of Open Access Journals (Sweden)

    Anil Kumar

    2014-01-01

    Full Text Available Introduction: Anchorage control is a critical consideration when planning treatment for patients with dental and skeletal malocclusions. To obtain sufficient stability of implants, the thickness of the soft tissue and the cortical-bone in the placement site must be considered; so as to provide an anatomical map in order to assist the clinician in the placement of the implants. Objective: The aim of this study is to evaluate the thickness of soft- and hard-tissue. Materials and Methods: To measure soft tissue and cortical-bone thicknesses, 12 maxillary cross-sectional specimens were obtained from the cadavers, which were made at three maxillary mid-palatal suture areas: The interdental area between the first and second premolars (Group 1, the second premolar and the first molar (Group 2, and the first and second molars (Group 3. Sectioned samples along with reference rulers were digitally scanned. Scanned images were calibrated and measurements were made with image-analysis software. We measured the thickness of soft and hard-tissues at five sectional areas parallel to the buccopalatal cementoenamel junction (CEJ line at 2-mm intervals and also thickness of soft tissue at the six landmarks including the incisive papilla (IP on the palate. The line perpendicular to the occlusal plane was made and measurement was taken at 4-mm intervals from the closest five points to IP. Results: (1 Group 1:6 mm from CEJ in buccal side and 2 mm from CEJ in palatal side. (2 Group 2:8 mm from CEJ in buccal side and 4 mm from CEJ in palatal side. (3 Group 3:8 mm from CEJ in buccal side and 8 mm from CEJ in palatal side. Conclusions: The best site for placement of implant is with thinnest soft tissue and thickest hard tissue, which is in the middle from CEJ in buccal side and closest from CEJ in palatal side in Group 1 and faraway from CEJ in buccal side and closest from CEJ in palatal side in Group 2 and faraway from CEJ in buccal side and faraway from CEJ in palatal

  2. Hard X-ray submicrometer tomography of human brain tissue at Diamond Light Source

    Science.gov (United States)

    Khimchenko, A.; Bikis, C.; Schulz, G.; Zdora, M.-C.; Zanette, I.; Vila-Comamala, J.; Schweighauser, G.; Hench, J.; Hieber, S. E.; Deyhle, H.; Thalmann, P.; Müller, B.

    2017-06-01

    There is a lack of the necessary methodology for three-dimensional (3D) investigation of soft tissues with cellular resolution without staining or tissue transformation. Synchrotron radiation based hard X-ray in-line phase contrast tomography using single-distance phase reconstruction (SDPR) provides high spatial resolution and density contrast for the visualization of individual cells using a standard specimen preparation and data reconstruction. In this study, we demonstrate the 3D characterization of a formalin-fixed paraffin-embedded (FFPE) human cerebellum specimen by SDPR at the Diamond-Manchester Imaging Branchline I13-2 (Diamond Light Source, UK) at pixel sizes down to 0.45 μm. The approach enables visualization of cerebellar layers (Stratum moleculare and Stratum granulosum), the 3D characterization of individual cells (Purkinje, stellate and granule cells) and can even resolve some subcellular structures (nucleus and nucleolus of Purkinje cells). The tomographic results are qualitatively compared to hematoxylin and eosin (H&E) stained histological sections. We demonstrate the potential benefits of hard X-ray microtomography for the investigations of biological tissues in comparison to conventional histology.

  3. Hard X-ray submicrometer tomography of human brain tissue at Diamond Light Source

    International Nuclear Information System (INIS)

    Khimchenko, A; Bikis, C; Schulz, G; Hieber, S E; Deyhle, H; Thalmann, P; Müller, B; Zdora, M-C; Zanette, I; Vila-Comamala, J; Schweighauser, G; Hench, J

    2017-01-01

    There is a lack of the necessary methodology for three-dimensional (3D) investigation of soft tissues with cellular resolution without staining or tissue transformation. Synchrotron radiation based hard X-ray in-line phase contrast tomography using single-distance phase reconstruction (SDPR) provides high spatial resolution and density contrast for the visualization of individual cells using a standard specimen preparation and data reconstruction. In this study, we demonstrate the 3D characterization of a formalin-fixed paraffin-embedded (FFPE) human cerebellum specimen by SDPR at the Diamond-Manchester Imaging Branchline I13-2 (Diamond Light Source, UK) at pixel sizes down to 0.45 μm. The approach enables visualization of cerebellar layers ( Stratum moleculare and Stratum granulosum ), the 3D characterization of individual cells (Purkinje, stellate and granule cells) and can even resolve some subcellular structures (nucleus and nucleolus of Purkinje cells). The tomographic results are qualitatively compared to hematoxylin and eosin (H and E) stained histological sections. We demonstrate the potential benefits of hard X-ray microtomography for the investigations of biological tissues in comparison to conventional histology. (paper)

  4. Magnetic resonance imaging of intraoral hard and soft tissues using an intraoral coil and FLASH sequences

    Energy Technology Data Exchange (ETDEWEB)

    Fluegge, Tabea; Eisenbeiss, Anne-Kathrin; Schmelzeisen, Rainer; Nelson, Katja [University Medical Center Freiburg, Department of Oral and Maxillofacial Surgery, Freiburg (Germany); Hoevener, Jan-Bernd; Ludwig, Ute; Hennig, Juergen [University Medical Center Freiburg, Medical Physics, Department of Radiology, Freiburg (Germany); Spittau, Bjoern [Albert Ludwig University of Freiburg, Institute of Anatomy and Cell Biology, Freiburg (Germany)

    2016-12-15

    To ascertain the feasibility of MRI as a non-ionizing protocol for routine dentomaxillofacial diagnostic imaging. Wireless coils were used for MRI of intraoral hard and soft tissues. FLASH MRI was applied in vivo with a mandible voxel size of 250 x 250 x 500 μm{sup 3}, FOV of 64 x 64 x 28 mm{sup 3} and acquisition time of 3:57 min and with a maxilla voxel size of 350 μm{sup 3} and FOV of 34 cm{sup 3} in 6:40 min. Ex vivo imaging was performed in 4:38 min, with a resolution of 200 μm{sup 3} and FOV of 36.5 cm{sup 3}. Cone beam (CB) CT of the mandible and subjects were acquired. MRI was compared to CBCT and histological sections. Deviations were calculated with intraclass correlation coefficient (ICC) and coefficient of variation (c{sub v}). A high congruence between CBCT, MRI and specimens was demonstrated. Hard and soft tissues including dental pulp, periodontium, gingiva, cancellous bone and mandibular canal contents were adequately displayed with MRI. Imaging of select intraoral tissues was achieved using custom MRI protocols with an easily applicable intraoral coil in a clinically acceptable acquisition time. Comparison with CBCT and histological sections helped demonstrate dimensional accuracy of the MR images. The course of the mandibular canal was accurately displayed with CBCT and MRI. (orig.)

  5. Magnetic resonance imaging of intraoral hard and soft tissues using an intraoral coil and FLASH sequences

    International Nuclear Information System (INIS)

    Fluegge, Tabea; Eisenbeiss, Anne-Kathrin; Schmelzeisen, Rainer; Nelson, Katja; Hoevener, Jan-Bernd; Ludwig, Ute; Hennig, Juergen; Spittau, Bjoern

    2016-01-01

    To ascertain the feasibility of MRI as a non-ionizing protocol for routine dentomaxillofacial diagnostic imaging. Wireless coils were used for MRI of intraoral hard and soft tissues. FLASH MRI was applied in vivo with a mandible voxel size of 250 x 250 x 500 μm 3 , FOV of 64 x 64 x 28 mm 3 and acquisition time of 3:57 min and with a maxilla voxel size of 350 μm 3 and FOV of 34 cm 3 in 6:40 min. Ex vivo imaging was performed in 4:38 min, with a resolution of 200 μm 3 and FOV of 36.5 cm 3 . Cone beam (CB) CT of the mandible and subjects were acquired. MRI was compared to CBCT and histological sections. Deviations were calculated with intraclass correlation coefficient (ICC) and coefficient of variation (c v ). A high congruence between CBCT, MRI and specimens was demonstrated. Hard and soft tissues including dental pulp, periodontium, gingiva, cancellous bone and mandibular canal contents were adequately displayed with MRI. Imaging of select intraoral tissues was achieved using custom MRI protocols with an easily applicable intraoral coil in a clinically acceptable acquisition time. Comparison with CBCT and histological sections helped demonstrate dimensional accuracy of the MR images. The course of the mandibular canal was accurately displayed with CBCT and MRI. (orig.)

  6. Nuclear-chemical methods in a hard tooth tissue abrasion study

    International Nuclear Information System (INIS)

    Gosman, A.; Spevacek, V.; Konicek, J.; Vopalka, D.; Housova, D.; Dolezalova, L.

    1999-01-01

    The advanced method consists in implantation-labelling of the thin surface layers of the solid objects, e.g. hard tooth tissue, by atoms of suitable natural or artificial radionuclides. Nuclides from the uranium series were implanted into the surface by using nuclear recoil effect at alpha decay of 226 Ra to 222 Rn, alpha decay of 222 Rn to RaA, alpha decay of RaA to RaB (beta-emitter) and further alpha or beta emitters. With regard to chosen alpha detection and to the half-lives of the radionuclides, there was actually measured the activity of 222 Rn, RaA and RaC' in the thin surface layer. This was followed by the laboratory simulation of the abrasion in the system of 'toothbrush - various suspensions of the tooth-pastes - hard tooth tissue (or material standard - ivory)' in specially designed device - the dentoabrasion meter. The activities of the tissue surface measured before and after abrasion were used for calculations of the relative drop of the surface activity. On this basis the influence of various tooth-pastes containing various abrasive substances was determined. (author)

  7. Environmental lead pollution and its possible influence on tooth loss and hard dental tissue lesions

    Directory of Open Access Journals (Sweden)

    Cenić-Milošević Desanka

    2013-01-01

    Full Text Available Bacground/Aim. Environmental lead (Pb pollution is a global problem. Hard dental tissue is capable of accumulating lead and other hard metals from the environment. The aim of this study was to investigate any correlation between the concentration of lead in teeth extracted from inhabitants of Pančevo and Belgrade, Serbia, belonging to different age groups and occurrence of tooth loss, caries and non-carious lesions. Methods. A total of 160 volunteers were chosen consecutively from Pančevo (the experimental group and Belgrade (the control group and divided into 5 age subgroups of 32 subjects each. Clinical examination consisted of caries and hard dental tissue diagnostics. The Decayed Missing Filled Teeth (DMFT Index and Significant Caries Index were calculated. Extracted teeth were freed of any organic residue by UV digestion and subjected to voltammetric analysis for the content of lead. Results. The average DMFT scores in Pančevo (20.41 were higher than in Belgrade (16.52; in the patients aged 31-40 and 41-50 years the difference was significant (p < 0.05 and highly significant in the patients aged 51-60 (23.69 vs 18.5, p < 0.01. Non-carious lesions were diagnosed in 71 (44% patients from Pančevo and 39 (24% patients from Belgrade. The concentrations of Pb in extracted teeth in all the groups from Pančevo were statistically significantly (p < 0.05 higher than in all the groups from Belgrade. In the patients from Pančevo correlations between Pb concentration in extracted teeth and the number of extracted teeth, the number of carious lesions and the number of non-carious lesions showed a statistical significance (p < 0.001, p < 0.01 and p < 0.001, respectively. Conclusion. According to correlations between lead concentration and the number of extracted teeth, number of carious lesions and non-carious lesions found in the patients living in Pančevo, one possible cause of tooth loss and hard dental tissue damage could be a long

  8. Effects of an Er, Cr:YSGG laser on canine oral hard tissues

    Science.gov (United States)

    Rizoiu, Ioana-Mihaela; Kimmel, Andrew I.; Eversole, Lewis R.

    1996-12-01

    Beagle dogs were utilized to assess the biologic effects of an Er, Cr:YSGG hard tissue cutting laser and results were compared with conventional mechanical preparations of enamel and dentin. Intraoperative pulpal temperature fluctuations were recorded with thermocouples. The laser cuts failed to induce inflammation in the pulps except in teeth with intentional pulp exposures for both methods. No increase in temperature was detected with the laser. It is concluded that this laser system may be safely employed for tooth preparations without causing adverse pulpal effects.

  9. [Investigation on noncarious hard tissue lesions of teeth in teachers of one university in Shanghai municipality].

    Science.gov (United States)

    Chen, Yi-li; Zhang, Zhe-dan; Guo, Jian-qing; Zhu, Ya-ping; Wang, Qun; Gao, Ling-yu

    2011-06-01

    To investigate the condition of four kinds of noncarious hard tissue lesions of the teeth in teachers of one university in Shanghai municipality and provide guidance about oral health care. The table and the standard on oral health survey authorized by WHO were adopted, condition of four kinds of noncarious hard tissue lesions of teeth in 776 teachers of East China University of Science was investigated and analyzed using SPSS16.0 software package. The average wedge-shaped defect teeth was 5.54±3.87, the incidence was 30.41%, caries incidence of the first bicuspid was the highest(29.52%). The incidence of tetracycline pigmentation teeth was 3.09%, the incidence of enamel hypoplasia was 2.06%, and the incidence of dental fluorosis was 1.55%. The average wedge-shaped defect teeth is higher than the data over the country, the incidence of dental textural anomaly is lower. The behaviors of oral health care of university teachers in Shanghai municipality remains to be further strengthened.

  10. Effects of gamma radiation on hard dental tissues of albino rats: investigation by light microscopy.

    Science.gov (United States)

    El-Faramawy, Nabil; Ameen, Reham; El-Haddad, Khaled; El-Zainy, Medhat

    2013-08-01

    The present work aims at studying the effect of gamma radiation on the hard dental tissues. Eighty adult male albino rats with weights of about 250 g were used. The rats were irradiated at 0.2, 0.5, 1.0, 2.0, 4.0 and 6.0 Gy whole-body gamma doses. The effects on hard dental tissue samples were investigated after 48 h in histological and ground sections using light microscopy. Areas of acid phosphatase activity were detected using tartrate-resistant acid phosphatase (TRAP) stains. Observation of histological sections revealed disturbance in predentin thickness and odontoblastic layer as the irradiation dose increased. In cementum, widened cementocytes lacunae were occasionally detected even with low irradiated doses. On the other hand, relatively homogenous enamel was detected with darkened areas in enamel surface at doses over than 0.5 Gy. TRAP-positive cells were detected on the surface of the dentin of irradiated groups as well as cementum surface. Minimal detectable changes were observed in ground sections.

  11. Method and device for bio-impedance measurement with hard-tissue applications

    International Nuclear Information System (INIS)

    Guimerà, A; Calderón, E; Los, P; Christie, A M

    2008-01-01

    Bio-impedance measurements can be used to detect and monitor several properties of living hard-tissues, some of which include bone mineral density, bone fracture healing or dental caries detection. In this paper a simple method and hardware architecture for hard tissue bio-impedance measurement is proposed. The key design aspects of such architecture are discussed and a commercial handheld ac impedance device is presented that is fully certified to international medical standards. It includes a 4-channel multiplexer and is capable of measuring impedances from 10 kΩ to 10 MΩ across a frequency range of 100 Hz to 100 kHz with a maximum error of 5%. The device incorporates several user interface methods and a Bluetooth link for bi-directional wireless data transfer. Low-power design techniques have been implemented, ensuring the device exceeds 8 h of continuous use. Finally, bench test results using dummy cells consisting of parallel connected resistors and capacitors, from 10 kΩ to 10 MΩ and from 20 pF to 100 pF, are discussed

  12. Evaluation of Metal Ion Concentration in Hard Tissues of Teeth in Residents of Central Poland

    Directory of Open Access Journals (Sweden)

    Piotr Wychowanski

    2017-01-01

    Full Text Available Objectives. The aim of the study was an assessment of the content of trace elements in enamel and dentin of teeth extracted in patients residing in urban and agricultural areas of Poland. Methods. The study included 30 generally healthy patients with retained third molars. 65 samples of enamel and dentin from individuals living in urban areas and 85 samples of enamel and dentin from individuals living in agricultural areas were prepared. The content of manganese, lead, cadmium, and chromium in the studied enamel and dentin samples from retained teeth was determined by Graphite Furnace Atomic Absorption Spectrometry. In the process of statistical hypothesis testing, the level of significance was assumed at α=0.05. Results. A comparative analysis of the data showed that enamel and dentin of inhabitants of industrialized areas contain significantly higher amounts of lead and cadmium than hard tissues of teeth in residents of agricultural areas and comparable amounts of manganese and chromium. Significance. It appears that hard tissues of retained teeth may constitute valuable material for assessment of long-term environmental exposure to metal ions. The study confirms that the risk of exposure to heavy metals depends on the place of residence and environmental pollution.

  13. Growth type of vertebral centra and the hard tissue observed by microradiography of the rainbow trout

    International Nuclear Information System (INIS)

    Kubo, Y.; Asano, H.

    1987-01-01

    To clarify the growth feature and the structure of hard tissue, we studied the vertebral centrum of rainbow trout Salmo gairdneri, using three specimens (BL: 21.0, 29.0 and 40.0cm). We examined the ratio of centrum length to centrum diameter in each vertebral centrum and obtained the value of 0.8-1.0 in most centra. This indicates that the vertebral centra of rainbow trout belong to the so-called equivalent type. The hard tissue was observed by microradiography, with the longitudinal and cross sections (about 100 μm)cut through the center of notochordal pore. The microradiograph of thin section of centrurn differentiated serially and changed in pattern, but it is clear to sustain the specific characteristics. In longitudinal sections, the V-shaped part of bone was composed of structure like compact bone through the length of vertebral column. In cross sections, the notochordal pore was enclosed by the radial trabecular bones, the arrangement gradually turning toward the posterior centra like paired fans set opposite each other laterally

  14. Method and device for bio-impedance measurement with hard-tissue applications.

    Science.gov (United States)

    Guimerà, A; Calderón, E; Los, P; Christie, A M

    2008-06-01

    Bio-impedance measurements can be used to detect and monitor several properties of living hard-tissues, some of which include bone mineral density, bone fracture healing or dental caries detection. In this paper a simple method and hardware architecture for hard tissue bio-impedance measurement is proposed. The key design aspects of such architecture are discussed and a commercial handheld ac impedance device is presented that is fully certified to international medical standards. It includes a 4-channel multiplexer and is capable of measuring impedances from 10 kOmega to 10 MOmega across a frequency range of 100 Hz to 100 kHz with a maximum error of 5%. The device incorporates several user interface methods and a Bluetooth link for bi-directional wireless data transfer. Low-power design techniques have been implemented, ensuring the device exceeds 8 h of continuous use. Finally, bench test results using dummy cells consisting of parallel connected resistors and capacitors, from 10 kOmega to 10 MOmega and from 20 pF to 100 pF, are discussed.

  15. A novel basalt fiber-reinforced polylactic acid composite for hard tissue repair.

    Science.gov (United States)

    Chen, Xi; Li, Yan; Gu, Ning

    2010-08-01

    A basalt fiber (BF) was, for the first time, introduced into a poly(l-lactic acid) (PLLA) matrix as innovative reinforcement to fabricate composite materials for hard tissue repair. Firstly, BF/PLLA composites and pure PLLA were produced by the methods of solution blending and freeze drying. The results showed that basalt fibers can be uniformly dispersed in the PLLA matrix and significantly improve the mechanical properties and hydrophilicity of the PLLA matrix. The presence of basalt fibers may retard the polymer degradation rate and neutralize the acid degradation from PLLA. Osteoblasts were cultured in vitro to evaluate the cytocompatibility of the composite. An MTT assay revealed that osteoblasts proliferated well for 7 days and there was little difference found in their viability on both PLLA and BF/PLLA films, which was consistent with the alkaline phosphatase (ALP) activity results. A fluorescent staining observation showed that osteoblasts grew well on the composites. SEM images displayed that osteoblasts tended to grow along the fiber axis. The formation of mineralized nodules was observed on the films by Alizarin red S staining. These results suggest that the presence of basalt fibers does not noticeably affect osteoblastic behavior and the designed composites are osteoblast compatible. It is concluded that basalt fibers, as reinforcing fibers, may have promising applications in hard tissue repair.

  16. A novel basalt fiber-reinforced polylactic acid composite for hard tissue repair

    International Nuclear Information System (INIS)

    Chen Xi; Li Yan; Gu Ning

    2010-01-01

    A basalt fiber (BF) was, for the first time, introduced into a poly(l-lactic acid) (PLLA) matrix as innovative reinforcement to fabricate composite materials for hard tissue repair. Firstly, BF/PLLA composites and pure PLLA were produced by the methods of solution blending and freeze drying. The results showed that basalt fibers can be uniformly dispersed in the PLLA matrix and significantly improve the mechanical properties and hydrophilicity of the PLLA matrix. The presence of basalt fibers may retard the polymer degradation rate and neutralize the acid degradation from PLLA. Osteoblasts were cultured in vitro to evaluate the cytocompatibility of the composite. An MTT assay revealed that osteoblasts proliferated well for 7 days and there was little difference found in their viability on both PLLA and BF/PLLA films, which was consistent with the alkaline phosphatase (ALP) activity results. A fluorescent staining observation showed that osteoblasts grew well on the composites. SEM images displayed that osteoblasts tended to grow along the fiber axis. The formation of mineralized nodules was observed on the films by Alizarin red S staining. These results suggest that the presence of basalt fibers does not noticeably affect osteoblastic behavior and the designed composites are osteoblast compatible. It is concluded that basalt fibers, as reinforcing fibers, may have promising applications in hard tissue repair.

  17. Hard dental tissue minimal-invasive preparation using contemporary polymer rotating instruments and laser

    Directory of Open Access Journals (Sweden)

    Beloica Miloš

    2014-01-01

    Full Text Available Goal of contemporary dentistry is to decrease the patient’s discomfort during treatment. Dentists aim to achieve maximum with the newly developed dental materials as well as with new cavity preparation techniques in the shortest time span. Since the development of the first constructed borer (drilling machine for caries removal, the preparation techniques have considerably changed. The progress of dental materials as well as the cavity preparation techniques has led us to contemporary carbide tungsten and diamond borers that are used with obligatory water cooling. The innovation within this field represents newly developed polymer borers that can detect the difference between carious lesions and healthy tooth structure. In this way the cavity preparation may be performed without damaging dental healthy tissue. This is possible owing to their hardness which is lower than the hardness of intact dentin. Polymer borer preparation is painless with less vibration, while the increase in temperature is negligible. Lasers have been used in clinical dentistry since 1980s so it can be said that they represent a new technology. The function of lasers is based on ablation which requires water. Erbium lasers have shown the highest potential with their ability to produce effective ablation of hard dental tissues. Laser application in dentistry requires special training as well as some protective measures. Laser advantages, compared to traditional preparation techniques, involve the absence of vibration, painless preparation, possibility of preparation without anesthetic and easier patient’s adjustment to dental intervention which is of importance, especially in pediatric dentistry. [Projekat Ministarstva nauke Republike Srbije, br. 46009

  18. Evaluation of human muscle hardness after dynamic exercise with ultrasound real-time tissue elastography: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Yanagisawa, O., E-mail: o.yanagisawa@aoni.waseda.jp [Faculty of Sport Sciences, Waseda University, Tokorozawa, Saitama (Japan); Niitsu, M. [Department of Radiological Science, Faculty of Health Sciences, Tokyo Metropolitan University, Arakawa-ku, Tokyo (Japan); Kurihara, T. [Faculty of Sport and Health Science, Ritsumeikan University, Kusatsu, Shiga (Japan); Fukubayashi, T. [Faculty of Sport Sciences, Waseda University, Tokorozawa, Saitama (Japan)

    2011-09-15

    Aim: To assess the feasibility of ultrasound real-time tissue elastography (RTE) for measuring exercise-induced changes in muscle hardness and to compare the findings of RTE with those of a tissue hardness meter for semi-quantitative assessment of the hardness of exercised muscles. Materials and methods: Nine male participants performed an arm-curl exercise. RTE measurements were performed by manually applying repetitive compression with the transducer on the scan position before exercise, immediately after exercise, and at 30 min after exercise; strain ratios between muscle and a reference material (hydrogel) were calculated (muscle strain/material strain). A tissue hardness meter was also used to evaluate muscle hardness. The intraclass correlation coefficients (ICCs) for the three repeated measurements at each measurement time were calculated to evaluate the intra-observer reproducibility of each technique. Results: Immediately after exercise, the strain ratio and the value obtained using the tissue hardness meter significantly decreased (from 1.65 to 1.35) and increased (from 51.8 to 54.3), respectively. Both parameters returned to their pre-exercise value 30 min after exercise. The ICCs of the RTE (and the ICCs of the muscle hardness meter) were 0.971 (0.816) before exercise, 0.939 (0.776) immediately after exercise, and 0.959 (0.882) at 30 min after exercise. Conclusion: Similar to the muscle hardness meter, RTE revealed the exercise-induced changes of muscle hardness semi-quantitatively. The intra-observer reproducibility of RTE was very high at each measurement time. These findings suggest that RTE is a clinically useful technique for assessing hardness of specific exercised muscles.

  19. Evaluation of human muscle hardness after dynamic exercise with ultrasound real-time tissue elastography: A feasibility study

    International Nuclear Information System (INIS)

    Yanagisawa, O.; Niitsu, M.; Kurihara, T.; Fukubayashi, T.

    2011-01-01

    Aim: To assess the feasibility of ultrasound real-time tissue elastography (RTE) for measuring exercise-induced changes in muscle hardness and to compare the findings of RTE with those of a tissue hardness meter for semi-quantitative assessment of the hardness of exercised muscles. Materials and methods: Nine male participants performed an arm-curl exercise. RTE measurements were performed by manually applying repetitive compression with the transducer on the scan position before exercise, immediately after exercise, and at 30 min after exercise; strain ratios between muscle and a reference material (hydrogel) were calculated (muscle strain/material strain). A tissue hardness meter was also used to evaluate muscle hardness. The intraclass correlation coefficients (ICCs) for the three repeated measurements at each measurement time were calculated to evaluate the intra-observer reproducibility of each technique. Results: Immediately after exercise, the strain ratio and the value obtained using the tissue hardness meter significantly decreased (from 1.65 to 1.35) and increased (from 51.8 to 54.3), respectively. Both parameters returned to their pre-exercise value 30 min after exercise. The ICCs of the RTE (and the ICCs of the muscle hardness meter) were 0.971 (0.816) before exercise, 0.939 (0.776) immediately after exercise, and 0.959 (0.882) at 30 min after exercise. Conclusion: Similar to the muscle hardness meter, RTE revealed the exercise-induced changes of muscle hardness semi-quantitatively. The intra-observer reproducibility of RTE was very high at each measurement time. These findings suggest that RTE is a clinically useful technique for assessing hardness of specific exercised muscles.

  20. Vascular imaging with contrast agent in hard and soft tissues using microcomputed-tomography.

    Science.gov (United States)

    Blery, P; Pilet, P; Bossche, A Vanden-; Thery, A; Guicheux, J; Amouriq, Y; Espitalier, F; Mathieu, N; Weiss, P

    2016-04-01

    Vascularization is essential for many tissues and is a main requisite for various tissue-engineering strategies. Different techniques are used for highlighting vasculature, in vivo and ex vivo, in 2-D or 3-D including histological staining, immunohistochemistry, radiography, angiography, microscopy, computed tomography (CT) or micro-CT, both stand-alone and synchrotron system. Vascularization can be studied with or without a contrast agent. This paper presents the results obtained with the latest Skyscan micro-CT (Skyscan 1272, Bruker, Belgium) following barium sulphate injection replacing the bloodstream in comparison with results obtained with a Skyscan In Vivo 1076. Different hard and soft tissues were perfused with contrast agent and were harvested. Samples were analysed using both forms of micro-CT, and improved results were shown using this new micro-CT. This study highlights the vasculature using micro-CT methods. The results obtained with the Skyscan 1272 are clearly defined compared to results obtained with Skyscan 1076. In particular, this instrument highlights the high number of small vessels, which were not seen before at lower resolution. This new micro-CT opens broader possibilities in detection and characterization of the 3-D vascular tree to assess vascular tissue engineering strategies. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.

  1. Pericardial and thoracic peri-aortic adipose tissues contribute to systemic inflammation and calcified coronary atherosclerosis independent of body fat composition, anthropometric measures and traditional cardiovascular risks

    International Nuclear Information System (INIS)

    Yun, Chun-Ho; Lin, Tin-Yu; Wu, Yih-Jer; Liu, Chuan-Chuan; Kuo, Jen-Yuan; Yeh, Hung-I.; Yang, Fei-Shih; Chen, Su-Chiu; Hou, Charles Jia-Yin; Bezerra, Hiram G.; Hung, Chung-Lieh; Cury, Ricardo C.

    2012-01-01

    Background: Coronary atherosclerosis has traditionally been proposed to be associated with several cardiovascular risk factors and anthropometric measures. However, clinical data regarding the independent value of visceral adipose tissue in addition to such traditional predictors remains obscure. Materials and methods: We subsequently studied 719 subjects (age: 48.1 ± 8.3 years, 25% females) who underwent multidetector computed tomography (MDCT) for coronary calcium score (CCS) quantification. Baseline demographic data and anthropometric measures were taken with simultaneous body fat composition estimated. Visceral adipose tissue of pericardial and thoracic peri-aortic fat was quantified by MDCT using TeraRecon Aquarius workstation (San Mateo, CA). Traditional cardiovascular risk stratification was calculated by metabolic (NCEP ATP III) and Framingham (FRS) scores and high-sensitivity CRP (Hs-CRP) was taken to represent systemic inflammation. The independent value of visceral adipose tissue to systemic inflammation and CCS was assessed by utilizing multivariable regression analysis. Results: Of all subjects enrolled in this study, the mean values for pericardial and peri-aortic adipose tissue were 74.23 ± 27.51 and 7.23 ± 3.69 ml, respectively. Higher visceral fat quartile groups were associated with graded increase of risks for cardiovascular diseases. Both adipose burdens strongly correlated with anthropometric measures including waist circumference, body weight and body mass index (all p < 0.001). In addition, both visceral amount correlates well with ATP and FRS scores, all lipid profiles and systemic inflammation marker in terms of Hs-CRP (all p < 0.001). After adjustment for baseline variables, both visceral fat were independently related to Hs-CRP levels (all p < 0.05), but only pericardial fat exerted independent role in coronary calcium deposit. Conclusion: Both visceral adipose tissues strongly correlated with systemic inflammation beyond traditional

  2. Influence of lead injection on calcium-45 distribution in hard tissues of rats

    International Nuclear Information System (INIS)

    Sato, Makoto

    1978-01-01

    This study determines the relationship between calcium distribution in hard tissues and age. The distribution of calcium was examined by using calcium-45 as tracer. Further, influences of such environmental toxic heavy metals as lead, cadmium and mercury upon calcium metabolism were determined. According to checks performed on 3-week-old rats, calcium-45 distributions in hard tissues from 6 hours to 6 days after injection were greater in the following tissues in the order listed: femurs, incisors, molars. In 2-week-old rats, the calcium distributions throughout the body were about the same. In 3-week-old rats, however, they were graded in descending order from femur to incisors, and then to molars. In rats of 18 weeks or more, the distribution of calcium-45 in the femur decreased. A slow increase was noted in calcium-45 deposits in the incisors of rats of four or more weeks; this increase remained constant at a very low level in rats of more than eight weeks. Calcium-45 distribution in rats of 61 weeks of age was graded in this descending order: incisors, femurs, and molars. In the group injected with calcium-45 and lead acetate, calcium-45 distribution was significantly less in 3-week-old than in 3-month-old rats. The following are percentages of calcium-45 distribution in rats to which 100 mg/kg of lead (equivalent of 1/3 of LD 50 were injected, when 100-percent distribution is assumed for controls; 3-week-old rats: femur 48 percent, incisors 49 percent, and molars 40 percent, 3-month-old rats: femurs 73 percent, incisors 67 percent, and molars 71 percent. No difference was observed in calcium-45 uptake between rats to whom injections of cadmium and mercury equivalent to 1/3 of a dose of LD 50 had been administered and rats who received only a single injection of calcium-45. (auth.)

  3. Laser ablation of hard tissue: correlation between the laser beam parameters and the post-ablative tissue characteristics

    Science.gov (United States)

    Serafetinides, Alexandros A.; Makropoulou, Mersini I.; Khabbaz, Maruan

    2003-11-01

    Hard dental tissue laser applications, such as preventive treatment, laser diagnosis of caries, laser etching of enamel, laser decay removal and cavity preparation, and more recently use of the laser light to enlarge the root canal during the endodontic therapy, have been investigated for in vitro and in vivo applications. Post-ablative surface characteristics, e.g. degree of charring, cracks and other surface deformation, can be evaluated using scanning electron microscopy. The experimental data are discussed in relevance with the laser beam characteristics, e.g. pulse duration, beam profile, and the beam delivery systems employed. Techniques based on the laser illumination of the dental tissues and the subsequent evaluation of the scattered fluorescent light will be a valuable tool in early diagnosis of tooth diseases, as carious dentin or enamel. The laser induced autofluorescence signal of healthy dentin is much stronger than that of the carious dentin. However, a better understanding of the transmission patterns of laser light in teeth, for both diagnosis and therapy is needed, before the laser procedures can be used in a clinical environment.

  4. Technetium-99m-HEDP concentration in calcified myoma

    International Nuclear Information System (INIS)

    Ell, P.J.; Breitfellner, G.; Meixner, M.

    1976-01-01

    This case emphasizes once more the need to interpret data in the clinical context, and it describes for the first time a concentration of /sup 99m/Tc-labeled HEDP in a calcified myoma of the uterus. Soft-tissue concentration of labeled phosphates should always be kept in mind when interpreting whole-body bone scans

  5. Successful penetration and bougie dilatation with Brockenbrough needle for severely calcified occlusion in superficial femoral artery.

    Science.gov (United States)

    Makita, Toshio; Suzuki, Kenji; Takizawa, Kaname; Ootomo, Tatsushi; Inoue, Naoto; Meguro, Taiichirou

    2014-04-01

    A 75-year-old hemodialysis patient with right critical limb ischemia received endovascular therapy for a chronic total occlusion (CTO) in a diffusely calcified superficial femoral artery (SFA). During a retrograde approach, a Brockenbrough needle (BN) was able to penetrate the calcified hard plaque formed in the middle segment of the CTO. Moreover, bougie dilatation with the BN allowed balloon crossing and stent deployment, even after failure to pass a 2.0-mm monorail balloon across the plaque. These results suggest that the BN offers a new therapeutic option in the penetration and modification of severely calcified CTO in SFA.

  6. Use of radioisotopes in the study of permeability of hard dental tissue

    International Nuclear Information System (INIS)

    Tarjan, I.

    1978-01-01

    A literature survey. According to in vivo experiments 32 P, 131 I and 45 Ca penetrate dental enamel and dentine. In vitro studies revealed that the healthy enamel and that damaged by caries and dentine are penetrable by 22 Na and 24 Na both in centripetal and in centrifugal directions. 32 P, 18 F and urea, labelled with 14 C penetrate healthy hard dental tissue. 45 CaCl 2 , 110 AgNO 3 , 111 AgNO 3 , 103 PdCl 2 , 64 Cu(NO 3 ) 2 , 63 ZnCl 2 , 65 ZnCl 2 and glucose, labelled with 14 C penetrate enamel defects, lamellas and caries areas. 239 Pu citrate complex links to the surface of enamel and cement, but does not penetrate them. (author)

  7. Precise femtosecond laser ablation of dental hard tissue: preliminary investigation on adequate laser parameters

    International Nuclear Information System (INIS)

    Hikov, Todor; Pecheva, Emilia; Petrov, Todor; Montgomery, Paul; Antoni, Frederic; Leong-Hoi, Audrey

    2017-01-01

    This work aims at evaluating the possibility of introducing state-of-the-art commercial femtosecond laser system in restorative dentistry by maintaining well-known benefits of lasers for caries removal, but also in overcoming disadvantages such as thermal damage of irradiated substrate. Femtosecond ablation of dental hard tissue is investigated by changing the irradiation parameters (pulsed laser energy, scanning speed and pulse repetition rate), assessed for enamel and dentin. The femtosecond laser system used in this work may be suitable for cavity preparation in dentin and enamel, due to the expected effective ablation and low temperature increase when using ultra short laser pulses. If adequate laser parameters are selected, this system seems to be promising for promoting a laser-assisted, minimally invasive approach in restorative dentistry. (paper)

  8. Use of radioisotopes in the study of permeability of hard dental tissue

    Energy Technology Data Exchange (ETDEWEB)

    Tarjan, I [Semmelweis Orvostudomanyi Egyetem, Budapest (Hungary)

    1978-04-01

    A literature survey. According to in vivo experiments /sup 32/P, /sup 131/I and /sup 45/Ca penetrate dental enamel and dentine. In vitro studies revealed that the healthy enamel and that damaged by caries and dentine are penetrable by /sup 22/Na and /sup 24/Na both in centripetal and in centrifugal directions. /sup 32/P, /sup 18/F and urea, labelled with /sup 14/C penetrate healthy hard dental tissue. /sup 45/CaCl/sub 2/, /sup 110/AgNO/sub 3/, /sup 111/AgNO/sub 3/, /sup 103/PdCl/sub 2/, /sup 64/Cu(NO/sub 3/)/sub 2/, /sup 63/ZnCl/sub 2/, /sup 65/ZnCl/sub 2/ and glucose, labelled with /sup 14/C penetrate enamel defects, lamellas and caries areas. /sup 239/Pu citrate complex links to the surface of enamel and cement, but does not penetrate them.

  9. Chronic radiation effects on dental hard tissue (''radiation carries''). Classification and therapeutic strategies

    International Nuclear Information System (INIS)

    Groetz, K.A.; Brahm, R.; Al-Nawas, B.; Wagner, W.; Riesenbeck, D.; Willich, N.; Seegenschmiedt, M.H.

    2001-01-01

    Objectives: Since the first description of rapid destruction of dental hard tissues following head and neck radiotherapy 80 years ago, 'radiation caries' is an established clinical finding. The internationally accepted clinical evaluation score RTOG/EORTC however is lacking a classification of this frequent radiogenic alteration. Material and Methods: Medical records, data and images of radiation effects on the teeth of more than 1,500 patients, who underwent periradiotherapeutic care, were analyzed. Macroscopic alterations regarding the grade of late lesions of tooth crowns were used for a classification into 4 grades according to the RTOG/EORTC guidelines. Results: No early radiation effects were found by macroscopic inspection. In the first 90 days following radiotherapy 1/3 of the patients complained of reversible hypersensitivity, which may be related to a temporary hyperemia of the pulp. It was possible to classify radiation caries as a late radiation effect on a graded scale as known from RTOG/EORTC for other organ systems. This is a prerequisite for the integration of radiation caries into the international nomenclature of the RTOG/EORTC classification. Conclusions: The documentation of early radiation effects on dental hard tissues seems to be neglectable. On the other hand the documentation of late radiation effects has a high clinical impact. The identification of an initial lesion at the high-risk areas of the neck and incisal part of the tooth can lead to a successful therapy as a major prerequisite for orofacial rehabilitation. An internationally standardized documentation is a basis for the evaluation of the side effects of radiooncotic therapy as well as the effectiveness of protective and supportive procedures. (orig.) [de

  10. General evaluation of hard dental tissue and risk factors of dental caries in young people

    Directory of Open Access Journals (Sweden)

    Антоніна Михайлівна Політун

    2016-04-01

    Full Text Available The prognostication of caries in youth is important for determination and prescription of individual prophylactic arrangements and its further influence on mineralization of the hard dental tissues.Aim of the work: the study of the prevalence and intensity of caries among the young people and determination of possible connection with the risk factor of caries development for further choice of the reasonable prophylactic arrangement.Materials and methods of research: epidemiological, clinical, statistic ones.Results of research: The article describes results of the comprehensive dental examination of 135 persons18-25 years old. There was determined the high prevalence of caries (96,3±0,74 % with considerable intensity (8,87±0,39. The main etiological factors among youth are: poor nutrition with prevalence of carbohydrate (74,81±0,56 %, lack of oral hygiene (59,27±0,73 %, quantitative and qualitative composition of oral fluid, presence of somatic diseases (40±0,30 %, bad habits (31,85±0,24 %, neglect of the sport (48,88±0,36 %, chronic emotional stress (38,51±0,29 %, due to the increased workload and related stress factors.Conclusions: the high prevalence (96,3±0,74 % and intensity of carious process (8,87±0,39 is caused by the unsatisfactory state of oral cavity, (1,91±0,06, under the influence of general factors (somatic diseases, stress, poor nutrition the reactivity of protective mechanisms is lowered and the risk of dental morbidity of youth increases. So, it proves the necessity of elaboration and introduction of the active arrangements of primary prophylaxis directed on the raise of caries resistance of the hard dental tissues in young people

  11. [The elemental composition of teeth hard tissues depending on the state of the environment].

    Science.gov (United States)

    Suladze, N; Shishniashvili, T; Margvelashvili, V; Kobakhidze, K

    2014-01-01

    At present, great attention is paid to the origin of man-made micro elemental anomalies. To monitor the state of the environment and its effects on the human body, of great importance is the determination of the amount and distribution of various chemical elements in the dentin and enamel of the teeth. To determine the essential (Ca, Zn, Mn, Ni), conditionally essential (Rb, Ni, Sr) and toxic (Pb, Hg) trace elements in the mineralized tissues of the teeth and to identify the relationship between the elemental composition of the tooth structure and the state of the general and dental health depending on the state of the environment, we have examined 29 children aged 3-4 years who have carried out analysis of hard tissue of teeth (teeth used for remote medical reasons) for the maintenance of nine chemical elements. Children living in a relatively environmentally favorable conditions essential value and conditionally essential elements in the mineralized tissues of the teeth were within normal limits, and toxic elements slightly increased limits that differ from those of children living in environmentally disadvantaged areas. In particular, these essential elements were significantly reduced (except for zinc), as indicators of toxic elements - mercury and lead, increased by 12.5% and 44.5%, respectively, which is clearly reflected on the state of dental health because noted decompensated form of tooth decay. Thus, deviations in a state of general and dental health of children associated with an imbalance of macro-and microelements in the mineralized tissues of the teeth.

  12. Hard and Soft Tissue Management of a Localized Alveolar Ridge Atrophy with Autogenous Sources and Biomaterials: A Challenging Clinical Case

    OpenAIRE

    C. Maiorana; D. Andreoni; P. P. Poli

    2016-01-01

    Particularly in the premaxillary area, the stability of hard and soft tissues plays a pivotal role in the success of the rehabilitation from both a functional and aesthetic aspect. The present case report describes the clinical management of a localized alveolar ridge atrophy in the area of the upper right canine associated with a thin gingival biotype with a lack of keratinized tissue. An autogenous bone block harvested from the chin associated with heterologous bone particles was used to re...

  13. Manual Aspiration Thrombectomy in Patients with Acute Stroke-Related Calcified Cerebral Emboli.

    Science.gov (United States)

    Koh, Esther; Kwak, Hyo Sung; Chung, Gyung-Ho

    2017-10-01

    The aim of this study was to evaluate the effectiveness of mechanical aspiration thrombectomy (MAT) in patients with acute ischemic stroke from calcified cerebral emboli. Procedural results were reviewed for acute stroke patients with clinically neurological deficits who underwent recanalization from October 2012 through September 2015. Initial imaging studies and cerebral angiography were analyzed. Of the total number of patients with acute stroke, 5 patients were confirmed to have acute ischemic stroke by calcified cerebral emboli. On initial brain computed tomographic imaging, all patients showed small, dense single calcifications in the middle cerebral artery with no definitive ischemic low-density lesions (M1: 3, M2: 2, mean size: 4.8 mm). All patients had angiographic findings of filling defects from calcified emboli. Four patients had good collateral flow and two had continuous distal flow. All patients underwent MAT using a Penumbra catheter (Penumbra Inc., Alameda, CA). MAT did not remove calcified emboli in all patients. Two patients with good collateral flow had favorable functional outcomes (modified Rankin Scale score ≤2). Four patients had diffuse calcification in the aortic arch, carotid artery, and aortic valve. Cerebral angiography supports a diagnosis of stroke when calcified cerebral emboli have contrast-filling defects and a degree of vascular occlusion. However, in this study, MAT was not an effective treatment for patients with calcified cerebral emboli because of hardness of the calcified plaque and packing into the arterial lumen. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  14. Establishing the soft and hard tissue area centers (centroids) for the skull and introducing a newnon-anatomical cephalometric line

    International Nuclear Information System (INIS)

    AlBalkhi, Khalid M; AlShahrani, Ibrahim; AlMadi, Abdulaziz

    2008-01-01

    The purpose of this study was to demonstrate how to establish the area center (centroid) of both the soft and hard tissues of the outline of the lateral cephalometric skull image, and to introduce the concept of a new non-anatomical centroid line. Lateral cephalometric radiographs, size 12 x 14 inch, of fifty seven adult subjects were selected based on their pleasant, balanced profile, Class I skeletal and dental relationship and no major dental malocclusion or malrelationship. The area centers (centroids) of both soft and hard tissue skull were practically established using a customized software computer program called the m -file . Connecting the two centers introduced the concept of a new non-anatomical soft and hard centroids line. (author)

  15. The effect of gastric juice on the development of erosive changes in hard dental tissue

    Directory of Open Access Journals (Sweden)

    Stojšin Ivana

    2014-01-01

    Full Text Available Introduction. Gastroesophageal reflux disease (GERD is an esophageal disorder where the refluxed gastric contents enters first into the esophagus followed by the pharynx, oral cavity, larynx, airway and middle ear, causing a range of disorders and symptoms. Hydrochloric acid from the gastric contents is responsible for the demineralization of dental hard tissues and release of matrix metalloproteinase from the dentin. Objective. The aim of this study was to verify the SEM (scanning electron microscopy analysis of the surface enamel, the enamel-dentin border and dentine after the exposure of intact teeth to filtrate of gastric contents obtained during routine endoscopy. Methods. Material used in the research was 10 extracted human impacted third molars. The coronal part of the tooth was divided into two parts, and then the two halves of teeth were exposed to the filtrate of gastric juice obtained during routine gastroscopy, which had been frozen until the moment of the experiment initiation. All samples of teeth were immersed in the filtrate of the content at a temperature of 20°C for 60 minutes. The prepared samples were observed by the SEM in the area of the enamel, the enamel-dentin border and in the area of dentin at different magnification. Results. The SEM analysis showed that both enamel and dentin had a significant demineralization of these tissues. Enamel surface resembled a demineralization similar to that of acid conditioning before the application of composite restorations. The degree of mineralization was more intense towards the enamel - dentin border, and at this area the enamel prisms were not fully recognizable. The dentin had a complete loss of peritubular dentin, the entry points of the dentin tubules were expanded and intertubular dentin demineralization was also registered. Conclusion. SEM analysis showed a significant degree of destruction of enamel and dentin. Significant changes in the surface structure of enamel and

  16. Evaluation of erbium:YAG and holmium:YAG laser radiation and dental hard tissue

    Science.gov (United States)

    Attrill, David Cameron

    Lasers have become increasingly established in medicine as effective alternatives or adjuncts to conventional techniques. In dentistry, several clinical laser systems have been developed and marketed, but their applications have been limited to soft tissue surgery. To date, no laser has been capable of effectively cutting or modifying the highly mineralised dental tissues of enamel and dentine. The aim of this study was to evaluate two new laser systems for use in dentistry through a series of in vitro experiments. Both generic erbium and holmium lasers have theoretically superior operating characteristics over currently established lasers for applications with dental hard tissues. The two lasers investigated in this study were pulsed Er:YAG (lambda=2.94) a.m. and Cr-Tm-Ho:YAG (lambda=2.1mu.m). Both operated with a macropulse duration of approximately 200lambdas, at pulse repetition rates of 2-8Hz and mean pulse energies up to 230mJ. Radiation was focused using CaF[2] lenses (f=50-120mm). The lasers could be operated with or without the addition of a surface water film at the interaction site. Tissue removal efficiency was expressed as a latent heat of ablation (LHA, kJ/cm[3]) using a modification of the technique described by Charlton et al. (1990). The mean LHA's for the Er:YAG laser were 6.24kJ/cm[3] and 22.99kJ/cm[3] with dentine and enamel respectively without water, and 10.07kJ/cm[3] and 18.73kJ/cm[3] for dentine and enamel with water. The Cr-Tm-Ho:YAG laser was unable to effectively remove enamel at the fluences and pulse energies available; the mean LHA's for the Cr-Tm- Ho:YAG laser with dentine were 82.79kJ/cm3 and 57.57kJ/cm3 with and without water respectively. The Cr-Tm-Ho;YAG was approximately 8-9 times less efficient for tissue removal than the Er:YAG system. Er:YAG tissue removal with water was characterised by clean "surgical" cuts, comparable in histological appearance to those obtained using conventional instrumentation. Some thermal disruption

  17. Interaction of ArF laser with dental hard tissue (AEM Study

    Directory of Open Access Journals (Sweden)

    Abbas Majdabadi

    2016-07-01

    Full Text Available Background and Aims: Nowadays lasers are used as alternatives to the tooth preparation because of reducing pain and bloodshed. The aim of this study was to observe the effect of ArF laser on the dental hard tissues. Materials and Methods: For this research human molar teeth with no caries or dental restoration and enamel cracks were used. Irradiation laser energies were taken 95, 70 and 50 mJ for enamel and 80, 70 and 50 mJ for dentine. Then, for each of energy values pulse numbers (repetition rate were adjusted at 200, 400, 600, 800, 1000 and 1500. Ablation was carried out without water spray on both enamel and dentine. Finally, the dimensions of ablated areas were measured by using a camera connected to the computer and results were applied in graphs. Results: For each energy value, the ablation dimension increased by increasing pulse numbers. Ablation depth in dentine was more than that of for enamel. Trends of graphs for dentine and enamel were the same. SEM images of ablations by 95 mJ energy on enamel and 80 mJ energy on dentine showed sharp edges. Conclusion: Ablation depths increased by increasing pulse numbers, for each energy level. However, this increase was not that as expected, because the lack of water spray while irradiating.

  18. A hard tissue cephalometric comparative study between hand tracing and computerized tracing

    Directory of Open Access Journals (Sweden)

    Ramachandra Prabhakar

    2014-01-01

    Full Text Available Aims: To analyze and compare the angular and linear hard tissue cephalometric measurements using hand-tracing and computerized tracings with Nemoceph and Dolphin software systems. Subjects and Methods: A total of 30 cephalograms were randomly chosen for study with the following criteria, cephalograms of patients with good contrast, no distortion, and minimal radiographic artifacts were considered using the digital method (Kodak 8000 C with 12 angular and nine linear parameters selected for the study. Comparisons were determined by post-hoc test using Tukey HSD method. The N-Par tests were performed using Kruskal-Walli′s method. Statistical Analysis Used: ANOVA and post-hoc. Results: The results of this study show that there is no significant difference in the angular and linear measurements recorded. The P values were significant at 0.05 levels for two parameters, Co-A and Co-Gn with the hand-tracing method. This was significant in ANOVA and post-hoc test by Tukey HSD method. Conclusions: This study of comparison provides support for transition from digital hand to computerized tracing methodology. In fact, digital computerized tracings were easier and less time consuming, with the same reliability irrespective of each method of tracing.

  19. Measurement of hard tissue density of head phantom based on the HU by using CBCT

    International Nuclear Information System (INIS)

    Kim, Moon Sun; Kang, Dong Wan; Kim, Jae Duk

    2009-01-01

    The purpose of this study was to determine a conversion coefficient for Hounsfield Units(HU) to material density (g cm -3 ) obtained from cone-beam computed tomography (CBMercuRay TM ) data and to measure the hard tissue density based on the Hounsfield scale on dental head phantom. CT Scanner Phantom (AAPM) equipped with CT Number Insert consists of five cylindrical pins of materials with different densities and teflon ring was scanned by using the CBMercuRay TM (Hitachi, Tokyo, Japan) volume scanner. The raw data were converted into DICOM format and the HU of different areas of CT number insert measured by using CBWorks TM . Linear regression analysis and Student t-test were performed statistically. There was no significant difference (P>0.54) between real densities and measured densities. A linear regression was performed using the density, ρ (g cm -3 ), as the dependent variable in terms of the HU (H). The regression equation obtained was ρ=0.00072 H-0.01588 with an R2 value of 0.9968. Density values based on the Hounsfield scale was 1697.1 ± 24.9 HU in cortical bone, 526.5 ± 44.4 HU in trabecular bone, 2639.1 ± 48.7 HU in enamel, 1246.1 ± 39.4 HU in dentin of dental head phantom. CBCT provides an effective option for determination of material density expressed as Hounsfield Units.

  20. Odontoblasts: Specialized hard-tissue-forming cells in the dentin-pulp complex.

    Science.gov (United States)

    Kawashima, Nobuyuki; Okiji, Takashi

    2016-07-01

    Odontoblasts are specialized cells that produce dentin and exhibit unique morphological characteristics; i.e., they extend cytoplasmic processes into dentinal tubules. While osteoblasts, which are typical hard-tissue-forming cells, are generated from mesenchymal stem cells during normal and pathological bone metabolism, the induction of odontoblasts only occurs once during tooth development, and odontoblasts survive throughout the lives of healthy teeth. During the differentiation of odontoblasts, signaling molecules from the inner enamel epithelium are considered necessary for the differentiation of odontoblast precursors, i.e., peripheral dental papilla cells. If odontoblasts are destroyed by severe external stimuli, such as deep caries, the differentiation of dental pulp stem cells into odontoblast-like cells is induced. Various bioactive molecules, such as non-collagenous proteins, might be involved in this process, although the precise mechanisms responsible for odontoblast differentiation have not been fully elucidated. Recently, our knowledge about the other functional activities of odontoblasts (apart from dentin formation) has increased. For example, it has been suggested that odontoblasts might act as nociceptive receptors, and surveillance cells that detect the invasion of exogenous pathogens. The regeneration of the dentin-pulp complex has recently gained much attention as a promising future treatment modality that could increase the longevity of pulpless teeth. Finally, congenital dentin anomalies, which are concerned with the disturbance of odontoblast functions, are summarized. © 2016 Japanese Teratology Society.

  1. Electron microscopic studies of the matrix formation of hard tissue organized cell

    International Nuclear Information System (INIS)

    Chou, Ching-Eng

    1982-01-01

    In order to study the functions of odontoblast, especially on the matrix formation, odontoblasts of rats' incisor and molar teeth were used. The animals were sacrificed 5 minutes, 15 minutes, 30 minutes, 1 hour, 2 hours and 24 hours after 3 H-proline administration to obtain the specimen. The specimens were processed for electron microscopic autoradiography. The following results were obtained. 1. 5 minutes after 3 H-proline administration: Silver grains indicated 3 H-proline uptake were already noted within the cells and localized in the rough surfaced endoplasmic reticulum and surrounding ribosomes, partially within the karyoplasm. 2. 15 minutes after 3 H-proline administration: The number of silver grains were generally increased as compared with the findings obtained in 5 minutes. The localization moved to the Golgi apparatus and their surroundings. 3. 30 minutes after 3 H-proline administration: Silver grains obtained in Tome's fibers area and some in predentin. In this area granules derived from Golgi body were found. 4. 1 hour after 3 H-proline administration: The number of silver grains were generally decreased and more pronounced movement toward predentin, the marked movement of silver grains were obtained onto the collagen fibers and surroundings. 5. 2 hours after 3 H-proline administration: Silver grains moved to the calcified area and there collagen fibers became more remarkable. 6. 24 hours after 3 H-proline administration: No silver grains were founded in the odontoblast side but deposited in the predentin calcified area with stable condition. Based on the results of these observations, odontoblasts were shown to perform the function of synthesis, storage, transportation and control of collagen formation in addition to the role of matrix formation. (author)

  2. 2D beam hardening correction for micro-CT of immersed hard tissue

    Science.gov (United States)

    Davis, Graham; Mills, David

    2016-10-01

    Beam hardening artefacts arise in tomography and microtomography with polychromatic sources. Typically, specimens appear to be less dense in the center of reconstructions because as the path length through the specimen increases, so the X-ray spectrum is shifted towards higher energies due to the preferential absorption of low energy photons. Various approaches have been taken to reduce or correct for these artefacts. Pre-filtering the X-ray beam with a thin metal sheet will reduce soft energy X-rays and thus narrow the spectrum. Correction curves can be applied to the projections prior to reconstruction which transform measured attenuation with polychromatic radiation to predicted attenuation with monochromatic radiation. These correction curves can be manually selected, iteratively derived from reconstructions (this generally works where density is assumed to be constant) or derived from a priori information about the X-ray spectrum and specimen composition. For hard tissue specimens, the latter approach works well if the composition is reasonably homogeneous. In the case of an immersed or embedded specimen (e.g., tooth or bone) the relative proportions of mineral and "organic" (including medium and plastic container) species varies considerably for different ray paths and simple beam hardening correction does not give accurate results. By performing an initial reconstruction, the total path length through the container can be determined. By modelling the X-ray properties of the specimen, a 2D correction transform can then be created such that the predicted monochromatic attenuation can be derived as a function of both the measured polychromatic attenuation and the container path length.

  3. Preparation and characterization of gelatin–hydroxyapatite composite microspheres for hard tissue repair

    International Nuclear Information System (INIS)

    Chao, Shao Ching; Wang, Ming-Jia; Pai, Nai-Su; Yen, Shiow-Kang

    2015-01-01

    Gelatin–hydroxyapatite composite microspheres composed of 21% gelatin (G) and 79% hydroxyapatite (HA) with uniform morphology and controllable size were synthesized from a mixed solution of Ca(NO 3 ) 2 , NH 4 H 2 PO 4 and gelatin by a wet-chemical method. Material analyses such as X-ray diffraction (XRD), scanning/transmission electron microscopy examination (SEM/TEM) and inductively coupled plasma-mass spectroscopy (ICP-MS) were used to characterize G–HA microspheres by analyzing their crystalline phase, microstructure, morphology and composition. HA crystals precipitate along G fibers to form nano-rods with diameters of 6–10 nm and tangle into porous microspheres after blending. The cell culture indicates that G–HA composite microspheres without any toxicity could enhance the proliferation and differentiation of osteoblast-like cells. In a rat calvarial defect model, G–HA bioactive scaffolds were compared with fibrin glue (F) and Osteoset® Bone Graft Substitute (OS) for their capacity of regenerating bone. Four weeks post-implantation, new bone, mineralization, and expanded blood vessel area were found in G–HA scaffolds, indicating greater osteoconductivity and bioactivity than F and OS. - Highlights: • G–HA composite microspheres were prepared by hydroxyapatite and gelatin. • In vitro tests indicated that the G–HA microspheres were biocompatible and bioactive. • In in vitro tests, G–HA microspheres could be applied in hard tissue engineering. • G–HA had healed the bone defect and provides a high proportion of surface area to open space

  4. Preparation and characterization of gelatin–hydroxyapatite composite microspheres for hard tissue repair

    Energy Technology Data Exchange (ETDEWEB)

    Chao, Shao Ching [Department of Materials Science and Engineering, National Chung Hsing University, 250 Kuo-Kuang Road, Taichung 40227, Taiwan (China); Department of Minimally Invasive Skull Neurosurgery, Neurological Institute, Taichung Veterans General Hospital, 1650 Taiwan Boulevard, Sect. 4, Taichung, Taiwan (China); Department of Neurosurgery, ChangHua Hospital, Ministry of Health and Welfare, 80 Chung Cheng Road, Sect. 2 Chiu Kuan Village, Changhua 500, Taiwan (China); Wang, Ming-Jia; Pai, Nai-Su [Department of Materials Science and Engineering, National Chung Hsing University, 250 Kuo-Kuang Road, Taichung 40227, Taiwan (China); Yen, Shiow-Kang, E-mail: skyen@dragon.nchu.edu.tw [Department of Materials Science and Engineering, National Chung Hsing University, 250 Kuo-Kuang Road, Taichung 40227, Taiwan (China)

    2015-12-01

    Gelatin–hydroxyapatite composite microspheres composed of 21% gelatin (G) and 79% hydroxyapatite (HA) with uniform morphology and controllable size were synthesized from a mixed solution of Ca(NO{sub 3}){sub 2}, NH{sub 4}H{sub 2}PO{sub 4} and gelatin by a wet-chemical method. Material analyses such as X-ray diffraction (XRD), scanning/transmission electron microscopy examination (SEM/TEM) and inductively coupled plasma-mass spectroscopy (ICP-MS) were used to characterize G–HA microspheres by analyzing their crystalline phase, microstructure, morphology and composition. HA crystals precipitate along G fibers to form nano-rods with diameters of 6–10 nm and tangle into porous microspheres after blending. The cell culture indicates that G–HA composite microspheres without any toxicity could enhance the proliferation and differentiation of osteoblast-like cells. In a rat calvarial defect model, G–HA bioactive scaffolds were compared with fibrin glue (F) and Osteoset® Bone Graft Substitute (OS) for their capacity of regenerating bone. Four weeks post-implantation, new bone, mineralization, and expanded blood vessel area were found in G–HA scaffolds, indicating greater osteoconductivity and bioactivity than F and OS. - Highlights: • G–HA composite microspheres were prepared by hydroxyapatite and gelatin. • In vitro tests indicated that the G–HA microspheres were biocompatible and bioactive. • In in vitro tests, G–HA microspheres could be applied in hard tissue engineering. • G–HA had healed the bone defect and provides a high proportion of surface area to open space.

  5. Hard and Soft Tissue Management of a Localized Alveolar Ridge Atrophy with Autogenous Sources and Biomaterials: A Challenging Clinical Case

    Directory of Open Access Journals (Sweden)

    C. Maiorana

    2016-01-01

    Full Text Available Particularly in the premaxillary area, the stability of hard and soft tissues plays a pivotal role in the success of the rehabilitation from both a functional and aesthetic aspect. The present case report describes the clinical management of a localized alveolar ridge atrophy in the area of the upper right canine associated with a thin gingival biotype with a lack of keratinized tissue. An autogenous bone block harvested from the chin associated with heterologous bone particles was used to replace the missing bone, allowing for a prosthetic driven implant placement. Soft tissues deficiency was corrected by means of a combined epithelialized and subepithelial connective tissue graft. The 3-year clinical and radiological follow-up demonstrated symmetric gingival levels of the upper canines, with physiological peri-implant probing depths and bone loss. Thus, the use of autogenous tissues combined with biomaterials might be considered a reliable technique in case of highly aesthetic demanding cases.

  6. Exogenous mineralization of hard tissues using photo-absorptive minerals and femto-second lasers; the case of dental enamel.

    Science.gov (United States)

    Anastasiou, A D; Strafford, S; Thomson, C L; Gardy, J; Edwards, T J; Malinowski, M; Hussain, S A; Metzger, N K; Hassanpour, A; Brown, C T A; Brown, A P; Duggal, M S; Jha, A

    2018-04-15

    A radical new methodology for the exogenous mineralization of hard tissues is demonstrated in the context of laser-biomaterials interaction. The proposed approach is based on the use of femtosecond pulsed lasers (fs) and Fe 3+ -doped calcium phosphate minerals (specifically in this work fluorapatite powder containing Fe 2 O 3 nanoparticles (NP)). A layer of the synthetic powder is applied to the surface of eroded bovine enamel and is irradiated with a fs laser (1040 nm wavelength, 1 GHz repetition rate, 150 fs pulse duration and 0.4 W average power). The Fe 2 O 3 NPs absorb the light and may act as thermal antennae, dissipating energy to the vicinal mineral phase. Such a photothermal process triggers the sintering and densification of the surrounding calcium phosphate crystals thereby forming a new, dense layer of typically ∼20 μm in thickness, which is bonded to the underlying surface of the natural enamel. The dispersed iron oxide NPs, ensure the localization of temperature excursion, minimizing collateral thermal damage to the surrounding natural tissue during laser irradiation. Simulated brushing trials (pH cycle and mechanical force) on the synthetic layer show that the sintered material is more acid resistant than the natural mineral of enamel. Furthermore, nano-indentation confirms that the hardness and Young's modulus of the new layers are significantly more closely matched to enamel than current restorative materials used in clinical dentistry. Although the results presented herein are exemplified in the context of bovine enamel restoration, the methodology may be more widely applicable to human enamel and other hard-tissue regenerative engineering. In this work we provide a new methodology for the mineralisation of dental hard tissues using femtosecond lasers and iron doped biomaterials. In particular, we demonstrate selective laser sintering of an iron doped fluorapatite on the surface of eroded enamel under low average power and mid

  7. Prevalence of developmental dental hard-tissue anomalies and association with caries and oral hygiene status of children in Southwestern, Nigeria.

    Science.gov (United States)

    Popoola, Bamidele O; Onyejaka, Nneka; Folayan, Morenike O

    2016-07-07

    Developmental dental hard tissue anomalies are often associated with oral health problems. This study determined the clinical prevalence of developmental dental hard tissue anomalies in the permanent dentition of children resident in southwestern Nigeria and its association with dental caries and poor oral hygiene status. This was a cross-sectional study recruiting 1565 school children, 12 to 15 year old attending schools in Ibadan, Oyo State and Ile-Ife, Osun State. All eligible study participants had oral examinations conducted to determine presence of developmental hard dental tissue anomalies, caries and oral hygiene status. The prevalence of developmental dental hard tissue anomalies was determined. Logistic Poisson regression was used to determine the association of between developmental dental hard tissue anomalies, caries and oral hygiene status. Only 65 (4.2 %) children had clinically diagnosed developmental dental hard tissue anomalies. The most prevalent anomaly was enamel hypoplasia (2.2 %). More females (p = 0.003) and more children with middle socioeconomic class (p = 0.001) had enamel hypoplasia. The probability of having poor oral hygiene was significantly increased for children with developmental dental anomalies (APR: 0.07; 95 % CI: 0.03 - 0.12; p = 0.002). The probability of having caries was insignificantly increased for children with developmental dental hard tissue anomalies (APR: 0.005; 95 % CI: -0.03 - 0.04; p = 0.08). The most prevalence clinically detectable developmental dental hard tissue anomalies for the study population was enamel hypoplasia. The presence of developmental dental hard tissue anomalies significantly increased the chances of having poor oral hygiene but not caries. Further studies are required to understand if poor oral hygiene is associated with dental caries in children with developmental dental hard tissue anomalies.

  8. Chemical and physical analysis on hard tissues after irradiation with short pulse Nd:YAG laser

    International Nuclear Information System (INIS)

    Pereira, Andrea Antunes

    2003-01-01

    This work reports on a study that was designed to investigate chemical, physical and morphological alterations in the dental enamel surface. The influence of application of laser in enamel surface by microscopic technical, X-ray fluorescence for chemical analysis, physical property as well as hardness and thermal analysis with Nd:YAG laser is also pointed out. A prototype of Nd:YAG (Q-switched) laser developed at the Center of Lasers and Applications - Institute of Energetic and Nuclear Research, aiming applications in the Medical Sciences that typical wavelength of 1.064 nm was used. The modifications in human dental enamel chemical composition for major and trace elements are here outlined. The accuracy of procedures was performed by analysis of natural hydroxyapatite as standard reference material. The identification and quantification of the chemical elements presented in the dental tissue samples were performed trough EDS, XRF and INAA. We determined the rate Calcium/Phosphorus (Ca/P) for different techniques. We performed an analysis in different regions of the surface and for different areas allowing a description of the chemical change in the total area of the specimen and the assessment of the compositional homogeneity of the each specimen. A comparison between XRF and INAA is presented. Based on morphological analysis of the irradiated surfaces with short pulse Nd:YAG laser we determined the area surrounded by the irradiation for the parameters for this thesis, and this technique allowed us to visualize the regions of fusion and re-solidification. The energy densities ranged from 10 J/cm 2 to 40 J/cm 2 , with pulse width of 6, 10 e 200 ns, and repetition rates of 5 and 7 Hz. In this thesis, FTIR-spectroscopy is used to analyze powder of mineralized tissue as well as enamel, dentine, root and cementum for human and bovine teeth after irradiation with short-pulse Nd:YAG laser. Characteristic spectra were obtained for the proteins components and mineral

  9. The Effect of Arch Height and Material Hardness of Personalized Insole on Correction and Tissues of Flatfoot

    Directory of Open Access Journals (Sweden)

    Shonglun Su

    2017-01-01

    Full Text Available Flat foot is one of the common deformities in the youth population, seriously affecting the weight supporting and daily exercising. However, there is lacking of quantitative data relative to material selection and shape design of the personalized orthopedic insole. This study was to evaluate the biomechanical effects of material hardness and support height of personalized orthopedic insole on foot tissues, by in vivo experiment and finite element modeling. The correction of arch height increased with material hardness and support height. The peak plantar pressure increased with the material hardness, and these values by wearing insoles of 40° were apparently higher than the bare feet condition. Harder insole material results in higher stress in the joint and ligament stress than softer material. In the calcaneocuboid joint, the stress increased with the arch height of insoles. The material hardness did not apparently affect the stress in the ankle joints, but the support heights of insole did. In general, insole material and support design are positively affecting the correction of orthopedic insole, but negatively resulting in unreasonable stress on the stress in the joint and ligaments. There should be an integration of improving correction and reducing stress in foot tissues.

  10. Assessing accumulated hard-tissue debris using micro-computed tomography and free software for image processing and analysis.

    Science.gov (United States)

    De-Deus, Gustavo; Marins, Juliana; Neves, Aline de Almeida; Reis, Claudia; Fidel, Sandra; Versiani, Marco A; Alves, Haimon; Lopes, Ricardo Tadeu; Paciornik, Sidnei

    2014-02-01

    The accumulation of debris occurs after root canal preparation procedures specifically in fins, isthmus, irregularities, and ramifications. The aim of this study was to present a step-by-step description of a new method used to longitudinally identify, measure, and 3-dimensionally map the accumulation of hard-tissue debris inside the root canal after biomechanical preparation using free software for image processing and analysis. Three mandibular molars presenting the mesial root with a large isthmus width and a type II Vertucci's canal configuration were selected and scanned. The specimens were assigned to 1 of 3 experimental approaches: (1) 5.25% sodium hypochlorite + 17% EDTA, (2) bidistilled water, and (3) no irrigation. After root canal preparation, high-resolution scans of the teeth were accomplished, and free software packages were used to register and quantify the amount of accumulated hard-tissue debris in either canal space or isthmus areas. Canal preparation without irrigation resulted in 34.6% of its volume filled with hard-tissue debris, whereas the use of bidistilled water or NaOCl followed by EDTA showed a reduction in the percentage volume of debris to 16% and 11.3%, respectively. The closer the distance to the isthmus area was the larger the amount of accumulated debris regardless of the irrigating protocol used. Through the present method, it was possible to calculate the volume of hard-tissue debris in the isthmuses and in the root canal space. Free-software packages used for image reconstruction, registering, and analysis have shown to be promising for end-user application. Copyright © 2014. Published by Elsevier Inc.

  11. SEM evaluation of the morphological changes in hard dental tissues prepared by Er: YAG laser and rotary instruments

    Directory of Open Access Journals (Sweden)

    Tomov Georgi

    2010-09-01

    Full Text Available Effective ablation of dental hard tissues by means of the erbium:yttrium-aluminum garnet (Er: YAG laser has been reported recently, and its application to caries removal and cavity preparation has been expected. However, few studies have investigated the morphological changes in hard dental tissues after Er: YAG laser caries treatment. In the present study the morphological changes in hard dental tissues after Er: YAG laser caries ablation in vitro was compared with that of conventional mechanical treatment. Thirty extracted human teeth with caries were used. Ten tooth was treated with the Er: YAG laser, and the other was treated with a conventional steel and diamond burs. Laser treatment was performed by means of a non-contact irradiation modes with cooling water spray, with a new Er: YAG laser (LiteTouch. Conventional bur treatment was conducted by means of a low-speed micromotor and air turbine with water cooling. Scanning electron microscope (SEM observations were performed for each treatment. The Er: YAG laser ablated carious dentin effectively with minimal thermal damage to the surrounding intact dentin, and removed infected and softened carious dentin to the same degree as the burtreatment. In addition, a lower degree of vibration was noted with the Er: YAG laser treatment. The SEM examination revealed characteristic micro-irregularities of the lased dentin and enamel surfaces with potential benefits for adhesive restorations. Our results show that the Er: YAG laser is promising as a new technical modality for caries treatment

  12. Interaction of slow highly charged ions with hard dental tissue: studies of fluoride uptake and reminalization efficacy

    International Nuclear Information System (INIS)

    Daskalova, A; Kasperski, G; Rousseau, P; Domaracka, A; Lawicki, A

    2014-01-01

    TOF-SIMS mass spectroscopy data are presented on ion irradiation of hard dental tissue using a beam of 129 Xe 20+ (15 kV) ions delivered in the ARIBE facility by an ECR source. The investigation was focused on the mass distribution of the fragment ions. A comparison is made between the mass spectra from hard dental tissue treated by olaflur-(C 27 H 60 F 2 N 2 O 3 ) and untreated hard dental tissue obtained under irradiation by low-energy highly-charged ions (HCIs). We found significant differences between the mass spectra of enamel after introducing amine fluoride (olaflur) and the mass spectra of pure untreated enamel. Further, we separated out the effects caused by radiation induced in the tooth enamel from those induced in dentin, which has not been performed before. In order to conduct a further detailed analysis, it is necessary to extend the research scope to include the influence of fluorine compounds on enamel and dentin.

  13. Studies on the method for determination of fluoride concentration in rat hard tissues by neutron activation analysis using 20F

    International Nuclear Information System (INIS)

    Nakakura, Tadao

    1991-01-01

    Neutron activation analysis method (non disruptive analysis, short time period measurement) has been recognized as a high precision analysis of fluoride concentration in hard tissue. Heat neutron irradiation analysis using instrumental neutron activation analysis (INAA) method was used to investigate 20 F concentration. Results were as follows. F concentration in a dried material of hard tissue using INAA method can be fixed by measuring the 20 F's energy peak for 10 seconds after neutron irradiation under 1 x 10 n/cm 2 ·s for 10 seconds. Non responding time that is caused by short half reduction time of 20 F can be recovered enough by a revise calculation. Reproducibility of measured fluoride concentration using INAA method was well stabilized. Rat hard tissue which takes no fluoride can be determined fluoride concentration without sodium restriction. Femur fluoride concentrations using INAA method had significant correlation with conventional microdiffusion analysis method (r=0.997, regression line: Y=1.13X + 2.98). Increase of fluoride density in dentine of rat molars under growing period according to fluoride intake was 1/3 of femurs and mandibles. (author)

  14. [Lasers in dentistry. Part B--Interaction with biological tissues and the effect on the soft tissues of the oral cavity, the hard tissues of the tooth and the dental pulp].

    Science.gov (United States)

    Moshonov, J; Stabholz, A; Leopold, Y; Rosenberg, I; Stabholz, A

    2001-10-01

    The interaction of laser energy with target tissue is mainly determined by two non operator-dependent factors: the specific wavelength of the laser and the optical properties of the target tissues. Power density, energy density, pulse repetition rate, pulse duration and the mode of energy transferring to the tissue are dictated by the clinician. Combination of these factors enables to control optimal response for the clinical application. Four responses are described when the laser beam hits the target tissue: reflection, absorption, transmission and scattering. Three main mechanisms of interaction between the laser and the biological tissues exist: photothermic, photoacoustic and photochemical. The effect of lasers on the soft tissues of the oral cavity is based on transformation of light energy into thermal energy which, in turn heats the target tissue to produce the desirable effect. In comparison to the scalpel used in surgical procedures, the laser beam is characterized by tissue natural sterility and by minimum bleeding during the surgical procedures due to blood vessels welding. The various effects achieved by the temperature elevation during the laser application on the soft tissue are: I. coagulation and hemostasis II. tissue sterilization III. tissue welding IV. incision and excision V. ablation and vaporization Ablation and melting are the two basic modalities by which the effect of lasers on the hard tissues of the tooth is produced. When discussing the effect of laser on dental hard tissues, the energy absorption in the hydroxyapatite plays a major role in addition to its absorption in water. When laser energy is absorbed in the water of the hard tissues, a rapid volume expansion of the evaporating water occurs as a result of a substantial temperature elevation in the interaction site. Microexplosions are produced causing hard tissue disintegration. If pulp temperatures are raised beyond 5 degrees C level, damage to the dental pulp is irreversible

  15. Study on the hard tissue changes in osteomyelitis of the jaws using CT image

    International Nuclear Information System (INIS)

    An, Chang Hyeon; Choi, Bo Ram; Huh, Kyung Hoe; Yi, Won Jin; Lee, Sam Sun; Choi, Soon Chul

    2009-01-01

    To assess the clinical findings and hard tissue changes of osteomyelitis of the jaws using computed tomographic (CT) image analysis. We reviewed and interpreted the CT images of 163 patients (64 males and 99 females, age range from 10 to 87 years) who visited the Seoul National University Dental Hospital from April 23, 2006 to December 31, 2008 and were diagnosed as osteomyelitis of the jaws through clinical, radiologic, and histopathologic examination. Each CT findings was investigated for frequency, correlation with age and gender. Of the 163 patients, 31 (19.0%) were affected on the maxilla, 135 (82.8%) were affected on the mandible, and 3 (1.8%) were affected on the both jaws simultaneously. The mean age of the patients who were affected on the maxilla was 61.0 years and that of the patients who were affected on the mandible was 56.2 years. On the maxilla, the most frequent site of disease was the posterior area (83.9%) and on the mandible, mandibular body (83.0%), followed by angle (48.1%), ramus (38.5%), condyle (13.3%), incisal area (9.6%), and coronoid process (3.0%). Among the 31 maxillary osteomyelitis, defect in the trabecular bone was observed in 28 (90.3%), osteosclerosis 20 (64.5%), defect in the cortical bone 27 (87.1%), sequestrum 17 (54.8%), and periosteal reaction 2 (6.5%). Among the 135 mandibular osteomyelitis, defect in the trabecular bone was observed in 100 (74.1%), osteosclerosis 104 (77.0%), defect in the cortical bone 116 (85.9%), sequestrum 36 (26.7%), and periosteal reaction 67 (49.6%). Of our cases, the maxillary osteomyelitis was visibly observed more frequently in females than males. The incidence is the highest in seventies (28.8%) and the lowest in teens (3.1%). The osteomyelitis of the jaws was observed more frequently in males than females before the age of 50, and observed more frequently in females after the age of 50. The most noticeable point was that the sequestrum was observed more often on maxillary osteomyelitis and the

  16. Preparation and Characterization of Biomimetic Hydroxyapatite-Resorbable Polymer Composites for Hard Tissue Repair

    Science.gov (United States)

    Hiebner, Kristopher Robert

    Autografts are the orthopedic "gold standard" for repairing bone voids. Autografts are osteoconductive and do not elicit an immune response, but they are in short supply and require a second surgery to harvest the bone graft. Allografts are currently the most common materials used for the repair of segmental defects in hard tissue. Unlike autografts, allografts can cause an undesirable immune response and the possibility of disease transmission is a major concern. As an alternative to the above approaches, recent research efforts have focused on the use of composite materials made from hydroxyapatite (HA) and bioresorbable polymers, such as poly-L-lactide (PLLA). Recent results have shown that the surface hydroxides on HA can initiate the ring opening polymerization (ROP) of L-lactide and other lactones creating a composite with superior interfacial strength. This thesis demonstrates that the surface of porous biologically derived HA substrates, such as coralline HA and trabecular bone, can be used to initiate the ROP of L-lactide and other lactones from the vapor phase. This process increases the strength of the porous scaffold through the deposition of a thin, uniform polymer coating, while maintaining the porous structure. The kinetics of the chemical vapor deposition polymerization (CVDP) are described using a quartz crystal microbalance (QCM). The reaction temperature and monomer vapor pressure are found to affect the rate of the polymerization. Also described in this thesis is the preparation of a porous polymer scaffold that mimics the structure of demineralized bone matrix (DBM). This demineralized bone matrix simulant (DBMS) is created using anorganic bovine bone as a template to initiate the polymerization of various lactones, followed by the removal of the HA scaffold. This material retained its shape and exhibits mechanical properties superior to DBM. Finally it is shown that HA can be used to initiate the ROP of a-caprolactam and the biocompatibility

  17. Design and synthesis of polyphosphazenes: Hard tissue scaffolding biomaterials and physically crosslinked elastomers

    Science.gov (United States)

    Modzelewski, Tomasz

    The work in this thesis is divided into two main parts. The first part examines the synthesis and characterization of polyphosphazenes as potential scaffolding materials usable for hard tissue repair. The goal of this work was to design polymers containing acidic functional groups in an attempt to encourage the deposition of calcium hydroxyapatite when the polymer is exposed to simulated body fluids. The second part examines the development of a new polymeric architecture which generates elastomeric properties without the use of traditional covalent or physical crosslinks. The goal was to examine the effects of this new architecture on the physical and mechanical properties of the final polymers. Chapter 1 provides a general background for the two main focus areas mentioned above. More specifically: a brief explanation is provided of the necessary physical and chemical properties of a suitable hard tissue engineering scaffolding substrate, and the basis of those requirements; together with an examination of the traditional ways in which elastomeric properties are introduced into a polymeric sample. Chapter 2 details the design and synthesis of polyphosphazenes bearing phosphonic acid and phosphoester side groups using two different routes. The first route utilized a linker unit which was functionalized with phosphoesters prior to its attachment to the polyphosphazene backbone, while the second route involved attachment of the same linking group to the polyphosphazene backbone before the introduction of the phosphoester moieties. In both cases, the samples were treated with iodotrimethylsilane to cleave the ester bonds and afford the parent phosphonic acid. Both routes proved successful. However, varying difficulties were encountered for each route. In Chapter 3 we examine the ability of the phosphonic acid functionalized polyphosphazenes described in Chapter 2 to mineralize calcium hydroxyapatite when exposed to simulated body fluid, which has the same ion

  18. Calcifying odontogenic cyst of anterior maxilla with complex odontoma

    Directory of Open Access Journals (Sweden)

    Yadavalli Guruprasad

    2014-01-01

    Full Text Available Calcifying odontogenic cyst (COC is an unusual and unique lesion with characteristics of a solid neoplasm and of a cyst. It shows considerable amount of histopathological diversity, with variable clinical behavior such as cystic, neoplastic and infiltrating malignant behavior. It is a rare developmental odontogenic cyst with notable presence of histopathological features, which include a cystic lining demonstrating characteristic "Ghost" epithelial cells with a propensity to calcify. Odontomes are best known as hamartomatous benign tumors rather than true neoplasms, arising from odontogenic tissues. Histologically, they are classified as compound and complex variety. We report a rare case of COC of anterior maxilla with complex odontome in a 12-year-old female child.

  19. Improved classification and visualization of healthy and pathological hard dental tissues by modeling specular reflections in NIR hyperspectral images

    Science.gov (United States)

    Usenik, Peter; Bürmen, Miran; Fidler, Aleš; Pernuš, Franjo; Likar, Boštjan

    2012-03-01

    Despite major improvements in dental healthcare and technology, dental caries remains one of the most prevalent chronic diseases of modern society. The initial stages of dental caries are characterized by demineralization of enamel crystals, commonly known as white spots, which are difficult to diagnose. Near-infrared (NIR) hyperspectral imaging is a new promising technique for early detection of demineralization which can classify healthy and pathological dental tissues. However, due to non-ideal illumination of the tooth surface the hyperspectral images can exhibit specular reflections, in particular around the edges and the ridges of the teeth. These reflections significantly affect the performance of automated classification and visualization methods. Cross polarized imaging setup can effectively remove the specular reflections, however is due to the complexity and other imaging setup limitations not always possible. In this paper, we propose an alternative approach based on modeling the specular reflections of hard dental tissues, which significantly improves the classification accuracy in the presence of specular reflections. The method was evaluated on five extracted human teeth with corresponding gold standard for 6 different healthy and pathological hard dental tissues including enamel, dentin, calculus, dentin caries, enamel caries and demineralized regions. Principal component analysis (PCA) was used for multivariate local modeling of healthy and pathological dental tissues. The classification was performed by employing multiple discriminant analysis. Based on the obtained results we believe the proposed method can be considered as an effective alternative to the complex cross polarized imaging setups.

  20. A systematic review on soft-to-hard tissue ratios in orthognathic surgery part II: Chin procedures.

    Science.gov (United States)

    San Miguel Moragas, Joan; Oth, Olivier; Büttner, Michael; Mommaerts, Maurice Y

    2015-10-01

    Precise soft-to-hard tissue ratios in orthofacial chin procedures are not well established. The aim of this study was to determine useful soft-to-hard tissue ratios for planning the magnitude of sliding genioplasty (chin osteotomy), osseous chin recontouring and alloplastic chin augmentation. A systematic review of English and non-English articles using PubMed central, ProQuest Dissertations and Theses, Science Citation Index, Elsevier Science Direct Complete, Highwire Press, Springer Standard Collection, SAGE premier 2011, DOAJ Directory of Open Access Journals, Sweetswise, Free E-Journals, Ovid Lippincott Williams & Wilkins total Access Collection, Wiley Online Library Journals, and Cochrane Plus databases from their onset until July 2014. Additional studies were identified by searching the references. Search terms included soft tissue, ratios, genioplasty, mentoplasty, chin, genial AND advancement, augmentation, setback, retrusion, impaction, reduction, vertical deficit, widening, narrowing, and expansion. Study selection criteria were as follows: only academic publications; human patients; no reviews; systematic reviews or meta-analyses; no cadavers; no syndromic patients; no pathology at the chin or mandible region; only articles of level of evidence from I to IV; number of patients must be cited in the articles; hard-to-soft tissue ratios must be cited in the articles or at least are able to be calculated with the quantitative data available in the article; if all patients of one article have had bilateral sagittal split osteotomy (BSSO) performed along with chin osteotomy, there should be an independent group evaluation of the data concerning to the chin; and no restriction regarding the size of the group. Independent extraction of articles by two authors using predefined data fields, including study quality indicators (level of evidence). The search identified 22 articles. Eleven additional articles were found in their reference sections. Of these, two were

  1. Generation of radicals in hard biological tissues under the action of laser radiation

    Science.gov (United States)

    Sviridov, Alexander P.; Bagratashvili, Victor N.; Sobol, Emil N.; Omelchenko, Alexander I.; Lunina, Elena V.; Zhitnev, Yurii N.; Markaryan, Galina L.; Lunin, Valerii V.

    2002-07-01

    The formation of radicals upon UV and IR laser irradiation of some biological tissues and their components was studied by the EPR technique. The radical decay kinetics in body tissue specimens after their irradiation with UV light were described by various models. By the spin trapping technique, it was shown that radicals were not produced during IR laser irradiation of cartilaginous tissue. A change in optical absorption spectra and the dynamics of optical density of cartilaginous tissue, fish scale, and a collagen film under exposure to laser radiation in an air, oxygen, and nitrogen atmosphere was studied.

  2. Relative Composition of Fibrous Connective and Fatty/Glandular Tissue in Connective Tissue Grafts Depends on the Harvesting Technique but not the Donor Site of the Hard Palate.

    Science.gov (United States)

    Bertl, Kristina; Pifl, Markus; Hirtler, Lena; Rendl, Barbara; Nürnberger, Sylvia; Stavropoulos, Andreas; Ulm, Christian

    2015-12-01

    Whether the composition of palatal connective tissue grafts (CTGs) varies depending on donor site or harvesting technique in terms of relative amounts of fibrous connective tissue (CT) and fatty/glandular tissue (FGT) is currently unknown and is histologically assessed in the present study. In 10 fresh human cadavers, tissue samples were harvested in the anterior and posterior palate and in areas close to (marginal) and distant from (apical) the mucosal margin. Mucosal thickness, lamina propria thickness (defined as the extent of subepithelial portion of the biopsy containing ≤25% or ≤50% FGT), and proportions of CT and FGT were semi-automatically estimated for the entire mucosa and for CTGs virtually harvested by split-flap (SF) preparation minimum 1 mm deep or after deepithelialization (DE). Palatal mucosal thickness, ranging from 2.35 to 6.89 mm, and histologic composition showed high interindividual variability. Lamina propria thickness (P >0.21) and proportions of CT (P = 0.48) and FGT (P = 0.15) did not differ significantly among the donor sites (anterior, posterior, marginal, apical). However, thicker palatal tissue was associated with higher FGT content (P tissue composition in the hard palate, DE-harvested CTG contains much larger amounts of CT and much lower amounts of FGT than SF-harvested CTG, irrespective of the harvesting site.

  3. Ectopic Hard Tissue Formation by Odonto/Osteogenically In Vitro Differentiated Human Deciduous Teeth Pulp Stem Cells.

    Science.gov (United States)

    Kim, Seunghye; Song, Je Seon; Jeon, Mijeong; Shin, Dong Min; Kim, Seong-Oh; Lee, Jae Ho

    2015-07-01

    There have been many attempts to use the pulp tissue from human deciduous teeth for dentin or bone regeneration. The objective of this study was to determine the effects of odonto/osteogenic in vitro differentiation of deciduous teeth pulp stem cells (DTSCs) on their in vivo hard tissue-forming potential. DTSCs were isolated from extracted deciduous teeth using the outgrowth method. These cells were exposed to odonto/osteogenic stimuli for 4 and 8 days (Day 4 and Day 8 groups, respectively), while cells in the control group were cultured in normal medium. The in vitro differentiated DTSCs and the control DTSCs were transplanted subcutaneously into immunocompromised mice with macroporous biphasic calcium phosphate and sacrificed at 8 weeks post-implantation. The effect of odonto/osteogenic in vitro differentiation was evaluated using alkaline phosphatase (ALP) staining and quantitative reverse transcription polymerase chain reaction (RT-PCR). The in vivo effect was evaluated by qualitative RT-PCR, assessment of ALP activity, histologic analysis, and immunohistochemical staining. The amount of hard tissue was greater in Day 4 group than Day 8 group (p = 0.014). However, Day 8 group generated lamellar bone-like structure, which was immunonegative to anti-human dentin sialoprotein with significantly low expression level of DSPP compared with the control group (p = 0.008). This study demonstrates that odonto/osteogenic in vitro differentiation of DTSCs enhances the formation of bone-like tissue, instead of dentin-like tissue, when transplanted subcutaneously using MBCP as a carrier. The odonto/osteogenic in vitro differentiation of DTSCs may be an effective modification that enhances in vivo bone formation by DTSCs.

  4. Comparative assessment of the interfacial soft and hard tissues investing implants and natural teeth in the macaque mandible.

    Science.gov (United States)

    Siar, Chong Huat; Toh, Chooi Gait; Romanos, Georgios E; Ng, Kok Han

    2015-07-01

    The aim of this study was to conduct a comparative qualitative and quantitative assessment of the interfacial soft and hard tissues investing implants and natural teeth. The test sample consisted of six adult healthy male Macaca fascicularis with three-unit splinted crowns, each crown supported by an Ankylos screw-shaped titanium implant. These implants were placed in the mandibular premolar-second molar region, one side by an immediate-loading (IL) and the other by delayed-loading (DL) protocol. The animals were sacrificed after 3 months of functional loading. Another two monkeys with natural dentition served as controls. Nondecalcified sections were prepared for assessment of optical intensities (OI) under a confocal laser scanning microscope. In both the test (IL and DL) and control, the soft tissue complexes demonstrated a highly fluorescent keratinized layer and diminished cytoplasmic and enhanced membranous fluorescence in the remaining epithelium. Peri-implant mucosa was further characterized by an intense fluorescence at the junctional epithelium-implant interface and in the stromal mononuclear infiltrate. Connective tissue contact and periodontal ligament were weakly fluorescent. In hard tissues, a high fluorescence was observed in peri-implant woven bone and along the implant-bone interface. Mean OI was significantly higher in peri-implant woven bone than around teeth (P  0.05). Present findings suggest that peri-implant woven bone is highly mineralized, while the peri-implant and gingival mucosa share structural similarities. Optical intensities of interfacial tissues investing implants and teeth are related to their biological properties.

  5. Genetic basis of calcifying cystic odontogenic tumors.

    Directory of Open Access Journals (Sweden)

    Akane Yukimori

    Full Text Available Calcifying cystic odontogenic tumors (CCOTs are benign cystic tumors that form abnormally keratinized ghost cells. Mutations in CTNNB1, which encodes beta-catenin, have been implicated in the development of these tumors, but a causal relationship has not been definitively established. Thus, mutational hot spots in 50 cancer genes were examined by targeted next-generation sequencing in 11 samples of CCOT. Mutations in CTNNB1, but not in other genes, were observed in 10 of 11 cases. These mutations constitutively activate beta-catenin signaling by abolishing the phosphorylation sites Asp32, Ser33, or Ser37, and are similar to those reported in pilomatrixoma and adamantinomatous craniopharyngioma. In contrast, BRAF or NRAS mutations were observed in 12 and two control samples of ameloblastoma, respectively. In HEK293 cells, overexpression of mutated CTNNB1 also upregulated hair keratin, a marker of ghost cells. Furthermore, ghost cells were present in two cases of ameloblastoma with BRAF and CTNNB1 mutations, indicating that ghost cells form due to mutations in CTNNB1. The data suggest that mutations in CTNNB1 are the major driver mutations of CCOT, and that CCOT is the genetic analog of pilomatrixoma and adamantinomatous craniopharyngioma in odontogenic tissue.

  6. In vivo imaging of human oral hard and soft tissues by polarization-sensitive optical coherence tomography

    Science.gov (United States)

    Walther, Julia; Golde, Jonas; Kirsten, Lars; Tetschke, Florian; Hempel, Franz; Rosenauer, Tobias; Hannig, Christian; Koch, Edmund

    2017-12-01

    Since optical coherence tomography (OCT) provides three-dimensional high-resolution images of biological tissue, the benefit of polarization contrast in the field of dentistry is highlighted in this study. Polarization-sensitive OCT (PS OCT) with phase-sensitive recording is used for imaging dental and mucosal tissues in the human oral cavity in vivo. An enhanced polarization contrast of oral structures is reached by analyzing the signals of the co- and crosspolarized channels of the swept source PS OCT system quantitatively with respect to reflectivity, retardation, optic axis orientation, and depolarization. The calculation of these polarization parameters enables a high tissue-specific contrast imaging for the detailed physical interpretation of human oral hard and soft tissues. For the proof-of-principle, imaging of composite restorations and mineralization defects at premolars as well as gingival, lingual, and labial oral mucosa was performed in vivo within the anterior oral cavity. The achieved contrast-enhanced results of the investigated human oral tissues by means of polarization-sensitive imaging are evaluated by the comparison with conventional intensity-based OCT.

  7. Effects of gamma radiation on hard dental tissues of albino rats using scanning electron microscope - Part 1

    Science.gov (United States)

    El-Faramawy, Nabil; Ameen, Reham; El-Haddad, Khaled; Maghraby, Ahmed; El-Zainy, Medhat

    2011-12-01

    In the present study, 40 adult male albino rats were used to study the effect of gamma radiation on the hard dental tissues (enamel surface, dentinal tubules and the cementum surface). The rats were irradiated at 0.2, 0.5, 1.0, 2.0, 4.0 and 6.0 Gy gamma doses. The effects of irradiated hard dental tissues samples were investigated using a scanning electron microscope. For doses up to 0.5 Gy, there was no evidence of the existence of cracks on the enamel surface. With 1 Gy irradiation dose, cracks were clearly observed with localized erosive areas. At 2 Gy irradiation dose, the enamel showed morphological alterations as disturbed prismatic and interprismatic areas. An increase in dentinal tubules diameter and a contemporary inter-tubular dentine volume decrease were observed with higher irradiation dose. Concerning cementum, low doses,<0.5 Gy, showed surface irregularities and with increase in the irradiation dose to≥1 Gy, noticeable surface irregularities and erosive areas with decrease in Sharpey's fiber sites were observed. These observations could shed light on the hazardous effects of irradiation fields to the functioning of the human teeth.

  8. Preparation and Characterization of Polycaprolactone / Layered Double Hydroxide Nanocomposite for Hard Tissue Engineering Applications

    Directory of Open Access Journals (Sweden)

    M. Baradaran

    2016-12-01

    Full Text Available In recent years the use of nanomaterials in bone tissue engineering scaffold has been considered due to its imitating the structure of natural bone tissue which contains a nanocomposite structure mixed with a three-dimensional matrix. In the meantime, Polycaprol actone has been used as a bio-polymer in bone tissue engineering applications as a scaffold. The aim of this study is to develop porous scaffolds made of polycaprol actone/layered double hydroxide biocomposite, with appropriate mechanical, bioactive and biological properties, for bone tissue engineering application. The nanocomposite scaffolds were fabricated by the particulate leaching method and freeze-drying method. In this study, MG63 cells (osteosarcoma was investigated for cellular study. Energy dispersive X-ray analysis confirmed uniform distribution of ceramic phase in polycaprol actone matrix. The results of mechanical tests showed the increase in young’s modulus after addition of ceramic phase. The microscopic investigations demonstrated that the pores generated after addition of ceramic phase and the average size of pores was as large as 100-600μm. Also by the addition of LDH, the hydrophilicity of PCL increased but the rate of hydroxyapatite formation was delayed due to presence of magnesium ions. The cell culture experiments confirmed the attachment and proliferation of cells on the scaffolds. The results showed that the fabricated scaffolds have the potential to be used in cancellous bone tissue engineering.

  9. Staged Hard and Soft Tissue Reconstruction Followed by Implant Supported Restoration in the Aesthetic Zone: A Case Report.

    Science.gov (United States)

    Parthasarathy, Harinath; Ramachandran, Lakshmi; Tadepalli, Anupama; Ponnaiyan, Deepa

    2017-04-01

    Alveolar ridge deficiency is a common clinical consequence following tooth loss due to chronic periodontitis complicating ideal implant placement. Advanced hard and soft tissue augmentation procedures have been developed in the recent past with predictable clinical outcomes. A male patient presented with a Grade III mobile upper right central incisor associated with advanced bone loss and soft tissue deficit. Following extraction of tooth #11, socket augmentation was done using an autogenous cortico-cancellous block graft and subsequent soft tissue augmentation was done with palatal connective tissue graft. At the end of six months, a tapered self tapping implant fixture was placed with adequate primary stability and after eight weeks, second stage implant surgery was done with the Misch technique in order to recreate papillae and the implant was prosthetically restored. The alveolar ridge was adequately recontoured following the staged surgical protocol. The implant was well integrated at the end of 15 months. Execution of sequential surgical procedures in a highly deficient edentulous site made it possible to achieve of optimal pink and white aesthetics with stable implant supported fixed prosthesis.

  10. Parallel beam microradiography of dental hard tissue using synchrotron radiation and X-ray image magnification

    International Nuclear Information System (INIS)

    Takagi, S.; Chow, L.C.; Brown, W.E.; Dobbyn, R.C.; Kuriyama, M.

    1984-01-01

    A novel technique utilizing a highly parallel beam of monochromatic synchrotron radiation combined with X-ray image magnification has been used to obtain microradiographs of caries lesions in relatively thick tooth sections. Preliminary results reveal structural features not previously reported. This technique holds the promise of allowing one to follow the structural changes accompanying the formation, destruction and chemical repair of mineralized tissue in real time. (orig.)

  11. Influence of steel implant surface microtopography on soft and hard tissue integration.

    Science.gov (United States)

    Hayes, J S; Klöppel, H; Wieling, R; Sprecher, C M; Richards, R G

    2018-02-01

    After implantation of an internal fracture fixation device, blood contacts the surface, followed by protein adsorption, resulting in either soft-tissue adhesion or matrix adhesion and mineralization. Without protein adsorption and cell adhesion under the presence of micro-motion, fibrous capsule formation can occur, often surrounding a liquid filled void at the implant-tissue interface. Clinically, fibrous capsule formation is more prevalent with electropolished stainless steel (EPSS) plates than with current commercially pure titanium (cpTi) plates. We hypothesize that this is due to lack of micro-discontinuities on the standard EPSS plates. To test our hypothesis, four EPSS experimental surfaces with varying microtopographies were produced and characterized for morphology using the scanning electron microscope, quantitative roughness analysis using laser profilometry and chemical analysis using X-ray photoelectron spectroscopy. Clinically used EPSS (smooth) and cpTi (microrough) were included as controls. Six plates of each type were randomly implanted, one on both the left and right intact tibia of 18 white New Zealand rabbits for 12 weeks, to allow for a surface interface study. The results demonstrate that the micro-discontinuities on the upper surface of internal steel fixation plates reduced the presence of liquid filled voids within soft-tissue capsules. The micro-discontinuities on the plate under-surface increased bony integration without the presence of fibrous tissue interface. These results support the hypothesis that the fibrous capsule and the liquid filled void formation occurs mainly due to lack of micro-discontinuities on the polished smooth steel plates and that bony integration is increased to surfaces with higher amounts of micro-discontinuities. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 705-715, 2018. © 2017 Wiley Periodicals, Inc.

  12. Stem cell technology using bioceramics: hard tissue regeneration towards clinical application

    Directory of Open Access Journals (Sweden)

    Hiroe Ohnishi, Yasuaki Oda and Hajime Ohgushi

    2010-01-01

    Full Text Available Mesenchymal stem cells (MSCs are adult stem cells which show differentiation capabilities toward various cell lineages. We have already used MSCs for treatments of osteoarthritis, bone necrosis and bone tumor. For this purpose, culture expanded MSCs were combined with various ceramics and then implanted. Because of rejection response to allogeneic MSC implantation, we have utilized patients' own MSCs for the treatment. Bone marrow is a good cell source of MSCs, although the MSCs also exist in adipose tissue. When comparing osteogenic differentiation of these MSCs, bone marrow MSCs show more extensive bone forming capability than adipose MSCs. Thus, the bone marrow MSCs are useful for bone tissue regeneration. However, the MSCs show limited proliferation and differentiation capabilities that hindered clinical applications in some cases. Recent advances reveal that transduction of plural transcription factors into human adult cells results in generation of new type of stem cells called induced pluripotent stem cells (iPS cells. A drawback of the iPS cells for clinical applications is tumor formation after their in vivo implantation; therefore it is difficult to use iPS cells for the treatment. To circumvent the problem, we transduced a single factor of either SOX2 or NANOG into the MSCs and found high proliferation as well as osteogenic differentiation capabilities of the MSCs. The stem cells could be combined with bioceramics for clinical applications. Here, we summarize our recent technologies using adult stem cells in viewpoints of bone tissue regeneration.

  13. TOPICAL REVIEW: Stem cell technology using bioceramics: hard tissue regeneration towards clinical application

    Science.gov (United States)

    Ohnishi, Hiroe; Oda, Yasuaki; Ohgushi, Hajime

    2010-02-01

    Mesenchymal stem cells (MSCs) are adult stem cells which show differentiation capabilities toward various cell lineages. We have already used MSCs for treatments of osteoarthritis, bone necrosis and bone tumor. For this purpose, culture expanded MSCs were combined with various ceramics and then implanted. Because of rejection response to allogeneic MSC implantation, we have utilized patients' own MSCs for the treatment. Bone marrow is a good cell source of MSCs, although the MSCs also exist in adipose tissue. When comparing osteogenic differentiation of these MSCs, bone marrow MSCs show more extensive bone forming capability than adipose MSCs. Thus, the bone marrow MSCs are useful for bone tissue regeneration. However, the MSCs show limited proliferation and differentiation capabilities that hindered clinical applications in some cases. Recent advances reveal that transduction of plural transcription factors into human adult cells results in generation of new type of stem cells called induced pluripotent stem cells (iPS cells). A drawback of the iPS cells for clinical applications is tumor formation after their in vivo implantation; therefore it is difficult to use iPS cells for the treatment. To circumvent the problem, we transduced a single factor of either SOX2 or NANOG into the MSCs and found high proliferation as well as osteogenic differentiation capabilities of the MSCs. The stem cells could be combined with bioceramics for clinical applications. Here, we summarize our recent technologies using adult stem cells in viewpoints of bone tissue regeneration.

  14. How ocean acidification can benefit calcifiers.

    Science.gov (United States)

    Connell, Sean D; Doubleday, Zoë A; Hamlyn, Sarah B; Foster, Nicole R; Harley, Christopher D G; Helmuth, Brian; Kelaher, Brendan P; Nagelkerken, Ivan; Sarà, Gianluca; Russell, Bayden D

    2017-02-06

    Reduction in seawater pH due to rising levels of anthropogenic carbon dioxide (CO 2 ) in the world's oceans is a major force set to shape the future of marine ecosystems and the ecological services they provide [1,2]. In particular, ocean acidification is predicted to have a detrimental effect on the physiology of calcifying organisms [3]. Yet, the indirect effects of ocean acidification on calcifying organisms, which may counter or exacerbate direct effects, is uncertain. Using volcanic CO 2 vents, we tested the indirect effects of ocean acidification on a calcifying herbivore (gastropod) within the natural complexity of an ecological system. Contrary to predictions, the abundance of this calcifier was greater at vent sites (with near-future CO 2 levels). Furthermore, translocation experiments demonstrated that ocean acidification did not drive increases in gastropod abundance directly, but indirectly as a function of increased habitat and food (algal biomass). We conclude that the effect of ocean acidification on algae (primary producers) can have a strong, indirect positive influence on the abundance of some calcifying herbivores, which can overwhelm any direct negative effects. This finding points to the need to understand ecological processes that buffer the negative effects of environmental change. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Photobiomodulation of mesenchymal stem cells encapsulated in an injectable rhBMP4-loaded hydrogel directs hard tissue bioengineering.

    Science.gov (United States)

    Diniz, Ivana M A; Carreira, Ana C O; Sipert, Carla R; Uehara, Cindi M; Moreira, Maria S N; Freire, Laila; Pelissari, Cibele; Kossugue, Patrícia M; de Araújo, Daniele R; Sogayar, Mari C; Marques, Márcia M

    2018-06-01

    Photobiomodulation (PBM) therapy displays relevant properties for tissue healing and regeneration, which may be of interest for the tissue engineering field. Here, we show that PBM is able to improve cell survival and to interact with recombinant human Bone Morphogenetic Protein 4 (rhBMP4) to direct and accelerate odonto/osteogenic differentiation of dental derived mesenchymal stem cells (MSCs). MSCs were encapsulated in an injectable and thermo-responsive cell carrier (Pluronic ® F-127) loaded with rhBMP4 and then photoactivated. PBM improved MSCs self-renewal and survival upon encapsulation in the Pluronic ® F-127. In the presence of rhBMP4, cell odonto/osteogenic differentiation was premature and markedly improved in the photoactivated MSCs. An in vivo calvarial critical sized defect model demonstrated significant increase in bone formation after PBM treatment. Finally, a balance in the reactive oxygen species levels may be related to the favorable results of PBM and rhBMP4 association. PBM may act in synergism with rhBMP4 and is a promise candidate to direct and accelerate hard tissue bioengineering. © 2017 Wiley Periodicals, Inc.

  16. Hard- and soft-tissue contributions to the esthetics of the posed smile in growing patients seeking orthodontic treatment.

    Science.gov (United States)

    McNamara, Laurie; McNamara, James A; Ackerman, Marc B; Baccetti, Tiziano

    2008-04-01

    The purpose of this investigation was to broaden the understanding of how various skeletal, dental, and soft-tissue relationships are related to the esthetics of the smile in patients with malocclusions before orthodontic treatment. Images of the posed smile were captured from digital video clips of 60 growing patients (33 girls, 27 boys) seeking orthodontic treatment; they were judged by panels of laypersons and orthodontists. Discriminant analysis identified determinants of the "pleasing smile" from the results of a visual analog scale. Quantitative measurements of the soft and hard tissues were made by using the smile images, cephalometric radiographs, and study models. The esthetics of the smile were correlated with specific skeletal, dental, and soft-tissue structures in the anteroposterior, vertical, and transverse dimensions (Pearson test on non-topographic correlations). The esthetic smile judgments of orthodontists agreed with those of laypersons (r >0.93). The vertical thicknesses of the lips were the most significant component of a pleasant smile, for both the orthodontists (upper lip) and laypersons (lower lip) (discriminant power: 75%). The vertical thickness of the upper lip had a significant positive correlation with the position of the maxillary incisor. Vertical lip thickness proved to be the most influential variable in smile esthetics. The significant relationship of incisor protrusion with the vertical thickness of the vermilion border of the upper lip must be considered when planning orthodontic treatment.

  17. Bone up: craniomandibular development and hard-tissue biomineralization in neonate mice.

    Science.gov (United States)

    Thompson, Khari D; Weiss-Bilka, Holly E; McGough, Elizabeth B; Ravosa, Matthew J

    2017-10-01

    The presence of regional variation in the osteogenic abilities of cranial bones underscores the fact that the mechanobiology of the mammalian skull is more complex than previously recognized. However, the relationship between patterns of cranial bone formation and biomineralization remains incompletely understood. In four strains of mice, micro-computed tomography was used to measure tissue mineral density during perinatal development in three skull regions (calvarium, basicranium, mandible) noted for variation in loading environment, embryological origin, and ossification mode. Biomineralization levels increased during perinatal ontogeny in the mandible and calvarium, but did not increase in the basicranium. Tissue mineral density levels also varied intracranially, with density in the mandible being highest, in the basicranium intermediate, and in the calvarium lowest. Perinatal increases in, and elevated levels of, mandibular biomineralization appear related to the impending postweaning need to resist elevated masticatory stresses. Similarly, perinatal increases in calvarial biomineralization may be linked to ongoing brain expansion, which is known to stimulate sutural bone formation in this region. The lack of perinatal increase in basicranial biomineralization could be a result of earlier developmental maturity in the cranial base relative to other skull regions due to its role in supporting the brain's mass throughout ontogeny. These results suggest that biomineralization levels and age-related trajectories throughout the skull are influenced by the functional environment and ontogenetic processes affecting each region, e.g., onset of masticatory loads in the mandible, whereas variation in embryology and ossification mode may only have secondary effects on patterns of biomineralization. Knowledge of perinatal variation in tissue mineral density, and of normal cranial bone formation early in development, may benefit clinical therapies aiming to correct

  18. Fabrication and evaluation of silica-based ceramic scaffolds for hard tissue engineering applications.

    Science.gov (United States)

    Sadeghzade, Sorour; Emadi, Rahmatollah; Tavangarian, Fariborz; Naderi, Mozhgan

    2017-02-01

    In recent decades, bone scaffolds have received a great attention in biomedical applications due to their critical roles in bone tissue regeneration, vascularization, and healing process. One of the main challenges of using scaffolds in bone defects is the mechanical strength mismatch between the implant and surrounding host tissue which causes stress shielding or failure of the implant during the course of treatment. In this paper, space holder method was applied to synthesize diopside/forsterite composite scaffolds with different diopside content. During the sintering process, NaCl, as spacer agent, gradually evaporated from the system and produced desirable pore size in the scaffolds. The results showed that adding 10wt.% diopside to forsterite can enormously improve the bioactivity, biodegradability, and mechanical properties of the composite scaffolds. The size of crystals and pores of the obtained scaffolds were measured to be in the range 70-100nm and 100-250μm, respectively. Composite scaffolds containing 10wt.% diopside showed similar compressive strength and Young's modulus (4.36±0.3 and 308.15±7MPa, respectively) to that of bone. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Hard and soft tissue changes following alveolar ridge preservation: a systematic review.

    Science.gov (United States)

    MacBeth, Neil; Trullenque-Eriksson, Anna; Donos, Nikolaos; Mardas, Nikos

    2017-08-01

    Two focused questions were addressed within this systematic review. Q1) What is the effect of alveolar ridge preservation on linear and volumetric alveolar site dimensions, keratinised measurements, histological characteristics and patient-based outcomes when compared to unassisted socket healing. Q2) What is the size effect of these outcomes in three different types of intervention (guided bone regeneration, socket grafting and socket seal). An electronic search (MEDLINE, EMBASE, Cochrane Central Register LILACS, Web of Science) and hand-search was conducted up to June 2015. Randomised controlled trials (RCT) and controlled clinical trials (CCT); with unassisted socket healing as controls: were eligible in the analysis for Q1. RCTs, CCTs and large prospective case series with or without an unassisted socket healing as control group were eligible in the analysis for Q2. Nine papers (8 RCTs and 1 CCTs) were included in the analysis for Q1 and 37 papers (29 RCTs, 7 CCTs and 1 case series) for Q2. The risk for bias was unclear or high in most of the studies. Q1: the standardised mean difference (SMD) in vertical mid-buccal bone height between ARP and a non-treated site was 0.739 mm (95% CI: 0.332 to 1.147). The SMD when proximal vertical bone height and horizontal bone width was compared was 0.796mm (95% CI: -1.228 to 0.364) and 1.198 mm (95% CI: -0.0374 to 2.433). Examination of ARP sites revealed significant variation in vital and trabecular bone percentages and keratinised tissue width and thickness. Adverse events were routinely reported, with three papers reporting a high level of complications in the test and control groups and two papers reporting greater risks associated with ARP. No studies reported on variables associated with the patient experience in either the test or the control group. Q2: A pooled effect reduction (PER) in mid-buccal alveolar ridge height of -0.467 mm (95% CI: -0.866 to -0.069) was recorded for GBR procedures and -0.157 mm (95% CI

  20. Electrospun PVA/HAp nanocomposite nanofibers: biomimetics of mineralized hard tissues at a lower level of complexity.

    Science.gov (United States)

    Kim, Gyeong-Man; Asran, Ashraf Sh; Michler, Georg H; Simon, Paul; Kim, Jeong-Sook

    2008-12-01

    Based on the biomimetic approaches the present work describes a straightforward technique to mimic not only the architecture (the morphology) but also the chemistry (the composition) of the lowest level of the hierarchical organization of bone. This technique uses an electrospinning (ES) process with polyvinyl alcohol (PVA) and hydroxyapatite (HAp) nanoparticles. To determine morphology, crystalline structures and thermal properties of the resulting electrospun fibers with the pure PVA and PVA/HAp nanocomposite (NC) before electrospinning various techniques were employed, including transmission electron microscopy (TEM), high-resolution TEM (HR-TEM), scanning electron microscopy (SEM), x-ray diffraction (XRD), differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA). In addition, FT-IR spectroscopy was carried out to analyze the complex structural changes upon undergoing electrospinning as well as interactions between HAp and PVA. The morphological and crystallographic investigations revealed that the rod-like HAp nanoparticles exhibit a nanoporous morphology and are embedded within the electrospun fibers. A large number of HAp nanorods are preferentially oriented parallel to the longitudinal direction of the electrospun PVA fibers, which closely resemble the naturally mineralized hard tissues of bones. Due to abundant OH groups present in PVA and HAp nanorods, they strongly interact via hydrogen bonding within the electrospun PVA/HAp NC fibers, which results in improved thermal properties. The unique physiochemical features of the electrospun PVA/HAp NC nanofibers prepared by the ES process will open up a wide variety of future applications related to hard tissue replacement and regeneration (bone and dentin), not limited to coating implants.

  1. Electrospun PVA/HAp nanocomposite nanofibers: biomimetics of mineralized hard tissues at a lower level of complexity

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gyeong-Man; Asran, Ashraf Sh; Michler, Georg H [Institute of Physics, Martin-Luther-University Halle-Wittenberg, D-06099 Halle/S (Germany); Simon, Paul [Max-Planck Institute for Chemical Physics of Solids, Noethnitzer Strasse 40, D-01187 Dresden (Germany); Kim, Jeong-Sook [Department of Dental Technology, Daegu Health College, 702-722 Daegu (Korea, Republic of)], E-mail: gyeong.kim@physik.uni-halle.de

    2008-12-01

    Based on the biomimetic approaches the present work describes a straightforward technique to mimic not only the architecture (the morphology) but also the chemistry (the composition) of the lowest level of the hierarchical organization of bone. This technique uses an electrospinning (ES) process with polyvinyl alcohol (PVA) and hydroxyapatite (HAp) nanoparticles. To determine morphology, crystalline structures and thermal properties of the resulting electrospun fibers with the pure PVA and PVA/HAp nanocomposite (NC) before electrospinning various techniques were employed, including transmission electron microscopy (TEM), high-resolution TEM (HR-TEM), scanning electron microscopy (SEM), x-ray diffraction (XRD), differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA). In addition, FT-IR spectroscopy was carried out to analyze the complex structural changes upon undergoing electrospinning as well as interactions between HAp and PVA. The morphological and crystallographic investigations revealed that the rod-like HAp nanoparticles exhibit a nanoporous morphology and are embedded within the electrospun fibers. A large number of HAp nanorods are preferentially oriented parallel to the longitudinal direction of the electrospun PVA fibers, which closely resemble the naturally mineralized hard tissues of bones. Due to abundant OH groups present in PVA and HAp nanorods, they strongly interact via hydrogen bonding within the electrospun PVA/HAp NC fibers, which results in improved thermal properties. The unique physiochemical features of the electrospun PVA/HAp NC nanofibers prepared by the ES process will open up a wide variety of future applications related to hard tissue replacement and regeneration (bone and dentin), not limited to coating implants.

  2. Hydrodynamic model for ultra-short pulse ablation of hard dental tissue

    Energy Technology Data Exchange (ETDEWEB)

    London, R.A.; Bailey, D.S.; Young, D.A.; Alley, W.E.; Feit, M.D.; Rubenchik, A.M. [Lawrence Livermore National Lab., CA (United States); Neev, J. [Beckman Laser Inst., Irvine, CA (United States)

    1996-02-29

    A computational model for the ablation of tooth enamel by ultra-short laser pulses is presented. The role of simulations using this model in designing and understanding laser drilling systems is discussed. Pulses of duration 300 fsec and intensity greater than 10{sup 12} W/cm{sup 2} are considered. Laser absorption proceeds via multi-photon initiated plasma mechanism. The hydrodynamic response is calculated with a finite difference method, using an equation of state constructed from thermodynamic functions including electronic, ion motion, and chemical binding terms. Results for the ablation efficiency are presented. An analytic model describing the ablation threshold and ablation depth is presented. Thermal coupling to the remaining tissue and long-time thermal conduction are calculated. Simulation results are compared to experimental measurements of the ablation efficiency. Desired improvements in the model are presented.

  3. Calcifying Fibrous Pseudotumor of the Esophagus

    Directory of Open Access Journals (Sweden)

    Shou-Wu Lee

    2010-11-01

    Full Text Available Calcifying fibrous pseudotumor is an uncommon lesion and has recently been recognized as a distinctive fibrous lesion. Esophageal calcifying fibrous pseudotumor is extremely rare and, to the best of our knowledge, has never been reported before. A 54-year-old woman underwent upper gastrointestinal endoscopy and endoscopic ultrasound because of intermittent dysphagia. The results showed 1 isoechoic esophageal submucosal tumor over the deep mucosa and submucosal layers, with calcifications inside. The patient underwent tumor excision, and the diagnosis was confirmed by pathological features, with abundant collagen, calcification and inflammatory cell infiltration. She received regular follow-up at the clinic and no evidence of tumor recurrence was found.

  4. Increased uptake of sup(99m)Tc-MDP in calcified synovial sarcoma

    International Nuclear Information System (INIS)

    Horne, T.; Mogle, P.; Finsterbush, A.; Gordin, M.; Hadassah Univ. Hospital, Mount Scopus; Hadassah Univ. Hospital, Mount Scopus

    1983-01-01

    We present a case of a partially calcified synovial sarcoma of the soft tissues of the thigh in a young girl. The roentgenographic, arteriographic and radio-nuclide scans were unusual. The finding and possible causes of increased uptake of sup(99m)Tc-MDP in synovial sarcoma are discussed. (orig.)

  5. Targeting angiogenesis-dependent calcified neoplasms using combined polymer therapeutics.

    Directory of Open Access Journals (Sweden)

    Ehud Segal

    Full Text Available There is an immense clinical need for novel therapeutics for the treatment of angiogenesis-dependent calcified neoplasms such as osteosarcomas and bone metastases. We developed a new therapeutic strategy to target bone metastases and calcified neoplasms using combined polymer-bound angiogenesis inhibitors. Using an advanced "living polymerization" technique, the reversible addition-fragmentation chain transfer (RAFT, we conjugated the aminobisphosphonate alendronate (ALN, and the potent anti-angiogenic agent TNP-470 with N-(2-hydroxypropylmethacrylamide (HPMA copolymer through a Glycine-Glycine-Proline-Norleucine linker, cleaved by cathepsin K, a cysteine protease overexpressed at resorption sites in bone tissues. In this approach, dual targeting is achieved. Passive accumulation is possible due to the increase in molecular weight following polymer conjugation of the drugs, thus extravasating from the tumor leaky vessels and not from normal healthy vessels. Active targeting to the calcified tissues is achieved by ALN's affinity to bone mineral.The anti-angiogenic and antitumor potency of HPMA copolymer-ALN-TNP-470 conjugate was evaluated both in vitro and in vivo. We show that free and conjugated ALN-TNP-470 have synergistic anti-angiogenic and antitumor activity by inhibiting proliferation, migration and capillary-like tube formation of endothelial and human osteosarcoma cells in vitro. Evaluation of anti-angiogenic, antitumor activity and body distribution of HPMA copolymer-ALN-TNP-470 conjugate was performed on severe combined immunodeficiency (SCID male mice inoculated with mCherry-labeled MG-63-Ras human osteosarcoma and by modified Miles permeability assay. Our targeted bi-specific conjugate reduced VEGF-induced vascular hyperpermeability by 92% and remarkably inhibited osteosarcoma growth in mice by 96%.This is the first report to describe a new concept of a narrowly-dispersed combined polymer therapeutic designed to target both tumor and

  6. Aortic calcified particles modulate valvular endothelial and interstitial cells

    NARCIS (Netherlands)

    van Engeland, N.C.A.; Bertazzo, S.; Sarathchandra, P.; McCormack, A.; Bouten, C.V.C.; Yacoub, M.H.; Chester, A.H.; Latif, N.

    2017-01-01

    BACKGROUND: Normal and calcified human valve cusps, coronary arteries, and aortae harbor spherical calcium phosphate microparticles of identical composition and crystallinity, and their role remains unknown. OBJECTIVE: The objective was to examine the direct effects of isolated calcified particles

  7. Effect of laser beam on temperature distribution on artificial cylindrical shaped hard tissue bones

    Science.gov (United States)

    Al-Akhras, M.-Ali H.; Qaseer, Mohammad-Khair; Albiss, B. A.; Gezawa, Umar S.

    2018-02-01

    Samples from fresh lamb chest bones were made in cylindrical shapes to study the time variation of temperature T as functions of the cylindrical radius and depth when its front surface exposed to a laser beam of 110Mw power and 642nm wavelength. The laser beam was directed at the center of the front surface of the horizontal cylinder. The measurements were done in vacuum and at atmospheric pressure. Our data reveal the linear variation of T with time, followed by a gradual increase before it reaches a plateau value at higher time. This sort of behavior independent of the radius or the depth where the temperature was measured. Moreover, the maximum variation occurs on the front surface where the laser beam was hitting and diminishes gradually with depth deep inside the cylinder. Data at atmospheric pressure showed less changes in temperature. The temperature distribution in bone due to laser irradiation is very important for a rational use of laser therapy as well as in the surgery to minimizes the thermal tissue damage.

  8. Hard tissue ablation with a spray-assisted mid-IR laser

    International Nuclear Information System (INIS)

    Kang, H W; Rizoiu, I; Welch, A J

    2007-01-01

    The objective of this study was to understand the dominant mechanism(s) for dental enamel ablation with the application of water spray. A free-running Er,Cr:YSGG (yttrium, scandium, gallium, garnet) laser was used to ablate human enamel tissue at various radiant exposures. During dental ablation, distilled water was sprayed on the sample surface, and these results were compared to ablation without a spray (dry ablation). In order to identify dominant ablation mechanisms, transient acoustic waves were compared to ablation thresholds and the volume of material removed. The ablation profile and depth were measured using optical coherence tomography (OCT). Irregular surface modification, charring and peripheral cracks were associated with dry ablation, whereas craters for spray samples were relatively clean without thermal damage. In spite of a 60% higher ablation threshold for spray associated irradiations owing to water absorption, acoustic peak pressures were six times higher and ablation volume was up to a factor of 2 larger compared to dry ablation. The enhanced pressure and ablation performance of the spray-assisted process was the result of rapid water vaporization, material ejection with recoil stress, interstitial water explosion and possibly liquid-jet formation. With water cooling and abrasive/disruptive mechanical effects, the spray ablation can be a safe and efficient modality for dental treatment

  9. Hard tissue ablation with a spray-assisted mid-IR laser

    Science.gov (United States)

    Kang, H. W.; Rizoiu, I.; Welch, A. J.

    2007-12-01

    The objective of this study was to understand the dominant mechanism(s) for dental enamel ablation with the application of water spray. A free-running Er,Cr:YSGG (yttrium, scandium, gallium, garnet) laser was used to ablate human enamel tissue at various radiant exposures. During dental ablation, distilled water was sprayed on the sample surface, and these results were compared to ablation without a spray (dry ablation). In order to identify dominant ablation mechanisms, transient acoustic waves were compared to ablation thresholds and the volume of material removed. The ablation profile and depth were measured using optical coherence tomography (OCT). Irregular surface modification, charring and peripheral cracks were associated with dry ablation, whereas craters for spray samples were relatively clean without thermal damage. In spite of a 60% higher ablation threshold for spray associated irradiations owing to water absorption, acoustic peak pressures were six times higher and ablation volume was up to a factor of 2 larger compared to dry ablation. The enhanced pressure and ablation performance of the spray-assisted process was the result of rapid water vaporization, material ejection with recoil stress, interstitial water explosion and possibly liquid-jet formation. With water cooling and abrasive/disruptive mechanical effects, the spray ablation can be a safe and efficient modality for dental treatment.

  10. Human bone hardness seems to depend on tissue type but not on anatomical site in the long bones of an old subject.

    Science.gov (United States)

    Ohman, Caroline; Zwierzak, Iwona; Baleani, Massimiliano; Viceconti, Marco

    2013-02-01

    It has been hypothesised that among different human subjects, the bone tissue quality varies as a function of the bone segment morphology. The aim of this study was to assess and compare the quality, evaluated in terms of hardness of packages of lamellae, of cortical and trabecular bones, at different anatomical sites within the human skeleton. The contralateral six long bones of an old human subject were indented at different levels along the diaphysis and at both epiphyses of each bone. Hardness value, which is correlated to the degree of mineralisation, of both cortical and trabecular bone tissues was calculated for each indentation location. It was found that the cortical bone tissue was harder (+18%) than the trabecular one. In general, the bone hardness was found to be locally highly heterogeneous. In fact, considering one single slice obtained for a bone segment, the coefficient of variation of the hardness values was up to 12% for cortical bone and up to 17% for trabecular bone. However, the tissue hardness was on average quite homogeneous within and among the long bones of the studied donor, although differences up to 9% among levels and up to 7% among bone segments were found. These findings seem not to support the mentioned hypothesis, at least not for the long bones of an old subject.

  11. The effects of prostaglandin E2 in growing rats - Increased metaphyseal hard tissue and cortico-endosteal bone formation

    Science.gov (United States)

    Jee, W. S. S.; Ueno, K.; Deng, Y. P.; Woodbury, D. M.

    1985-01-01

    The role of in vivo prostaglandin E2 (PGE2) in bone formation is investigated. Twenty-five male Sprague-Dawley rats weighing between 223-267 g were injected subcutaneously with 0.3, 1.0, 3.0, and 6.0 mg of PGE2-kg daily for 21 days. The processing of the tibiae for observation is described. Radiographs and histomorphometric analyses are also utilized to study bone formation. Body weight, weights of soft tissues and bones morphometry are evaluated. It is observed that PGE2 depressed longitudinal bone growth, increased growth cartilage thickness, decreased degenerative cartilage cell size and cartilage cell production, and significantly increased proximal tibial metaphyseal hard tissue mass. The data reveal that periosteal bone formation is slowed down at higher doses of PGE2 and endosteal bone formation is slightly depressed less than 10 days post injection; however, here is a late increase (10 days after post injection) in endosteal bone formation and in the formation of trabecular bone in the marrow cavity of the tibial shaft. It is noted that the effects of PGE2 on bone formation are similar to the responses of weaning rats to PGE2.

  12. Calcifying nanoparticles associated encrusted urinary bladder cystitis

    Directory of Open Access Journals (Sweden)

    Tomislav M Jelic

    2008-10-01

    Full Text Available Tomislav M Jelic1, Rod Roque1, Uzay Yasar2, Shayna B Tomchin1, Jose M Serrato2, Samuel G Deem3, James P Tierney3, Ho-Huang Chang11Department of Pathology Charleston Area Medical Center, Charleston WV, USA; 2Urology Center of Charleston, Charleston WV, USA; 3Urologic-Surgical Assoc. of Charleston, Charleston WV, USAAbstract: Encrusted cystitis is a subtype of chronic cystitis characterized by multiple calcifications in the form of plaques located in the interstitium of the urinary bladder mucosa and frequently associated with mucosal ulcers. It is a very rare disease of controversial etiology. Our transmission electron microscopy of the calcified plaques of encrusted cystitis has revealed that the smallest formed particles (elementary units of these calcifications are electron-dense shells surrounding an electron lucent core, diagnostic of calcifying nanoparticles (previously called nanobacteria. We pioneer the notion that calcifying nanoparticles are the causative agents of encrusted urinary bladder cystitis.Keywords: calcifying nanoparticles, nanobacteria, encrusted cystitis

  13. A lateral cephalometric study of the hard- and soft tissue profile around the face in the mixed dentition

    International Nuclear Information System (INIS)

    Lee, Sang Rae; Ahn, Hyung Kyu

    1978-01-01

    A study was made investigate a relationship existing in the dentoskeletal framework and the soft tissue profile around the face, and compared the sexual differences between boys and girls having the normal occlusion in the mixed dentition. The lateral cephalograms were composed of 67 boys aged 10.3 years and 68 girls aged 10.4 years, respectively. By means of the lateral cephalograms, both the hard-and soft tissue structures were simultaneously analyzed, measured and evaluated by introducing the several reference items: S-N plane, palatal plane, mandibular plane, N-A line and A-P line for the dentoskeletal structures and N'-P' line for the soft tissue, and the 21 measuring points for the both structures. The significant findings were as follows: 1. In general the boys showed the larger nasal component dimension than did the girls, but the length and height of nose(N'-Prn and NA-Prn) showed the significant sexual difference among those when evaluated statistically. 2. The lip-thickness was found to be minimal in the region of nasion, greater in the region of pogonion, and much greater in the region of point A in the both sexes, but the only thickness over point A(A-A') showed the significant sexual difference statistically. 3. The upper and lower lip position were found to be located anteriorly to the esthetic line in the both sexes, but upper lip position showed the significant sexual difference when evaluated statistically. 4. The regions of nose and upper lip had a tendency not to be following the underlying skeletal profile.

  14. Immediate postoperative outcome of orthognathic surgical planning, and prediction of positional changes in hard and soft tissue, independently of the extent and direction of the surgical corrections required

    DEFF Research Database (Denmark)

    Donatsky, Ole; Bjørn-Jørgensen, Jens; Hermund, Niels Ulrich

    2011-01-01

    orthognathic correction using the computerised, cephalometric, orthognathic, surgical planning system (TIOPS). Preoperative cephalograms were analysed and treatment plans and prediction tracings produced by computerised interactive simulation. The planned changes were transferred to models and finally...... with the presently included soft tissue algorithms, the current study shows relatively high mean predictability of the immediately postoperative hard and soft tissue outcome, independent of the extent and direction of required orthognathic correction. Because of the relatively high individual variability, caution...

  15. Engineering of hyaline cartilage with a calcified zone using bone marrow stromal cells.

    Science.gov (United States)

    Lee, W D; Hurtig, M B; Pilliar, R M; Stanford, W L; Kandel, R A

    2015-08-01

    In healthy joints, a zone of calcified cartilage (ZCC) provides the mechanical integration between articular cartilage and subchondral bone. Recapitulation of this architectural feature should serve to resist the constant shear force from the movement of the joint and prevent the delamination of tissue-engineered cartilage. Previous approaches to create the ZCC at the cartilage-substrate interface have relied on strategic use of exogenous scaffolds and adhesives, which are susceptible to failure by degradation and wear. In contrast, we report a successful scaffold-free engineering of ZCC to integrate tissue-engineered cartilage and a porous biodegradable bone substitute, using sheep bone marrow stromal cells (BMSCs) as the cell source for both cartilaginous zones. BMSCs were predifferentiated to chondrocytes, harvested and then grown on a porous calcium polyphosphate substrate in the presence of triiodothyronine (T3). T3 was withdrawn, and additional predifferentiated chondrocytes were placed on top of the construct and grown for 21 days. This protocol yielded two distinct zones: hyaline cartilage that accumulated proteoglycans and collagen type II, and calcified cartilage adjacent to the substrate that additionally accumulated mineral and collagen type X. Constructs with the calcified interface had comparable compressive strength to native sheep osteochondral tissue and higher interfacial shear strength compared to control without a calcified zone. This protocol improves on the existing scaffold-free approaches to cartilage tissue engineering by incorporating a calcified zone. Since this protocol employs no xenogeneic material, it will be appropriate for use in preclinical large-animal studies. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  16. The calcified lung nodule: What does it mean?

    Directory of Open Access Journals (Sweden)

    Khan Ali

    2010-01-01

    Full Text Available The aim of this review is to present a pictorial essay emphasizing the various patterns of calcification in pulmonary nodules (PN to aid diagnosis and to discuss the differential diagnosis and the pathogenesis where it is known. The imaging evaluation of PN is based on clinical history, size, distribution and the gross appearance of the nodule as well as feasibility of obtaining a tissue diagnosis. Imaging is instrumental in the management of PN and one should strive not only to identify small malignant tumors with high survival rates but to spare patients with benign PN from undergoing unnecessary surgery. The review emphasizes how to achieve these goals. One of the most reliable imaging features of a benign lesion is a benign pattern of calcification and periodic follow-up with computed tomography showing no growth for 2 years. Calcification in PN is generally considered as a pointer toward a possible benign disease. However, as we show here, calcification in PN as a criterion to determine benign nature is fallacious and can be misleading. The differential considerations of a calcified lesion include calcified granuloma, hamartoma, carcinoid, osteosarcoma, chondrosarcoma and lung metastases or a primary bronchogenic carcinoma among others. We describe and illustrate different patterns of calcification as seen in PN on imaging.

  17. [Comparative study of expression of homeobox gene Msx-1, Msx-2 mRNA during the hard tissue formation of mouse tooth development].

    Science.gov (United States)

    Wang, Y; Wang, J; Gao, Y

    2001-07-01

    To observe and compare the expression pattern of Msx-1, Msx-2 mRNA during the different stages of hard tissue formation in the first mandibular molar of mouse and investigate the relationship between the two genes. First mandibular molar germs from 1, 3, 7 and 14-days old mouse were separated and reverse transcription-polymerase chain reaction was performed on the total RNA of them using Msx-1, Msx-2 specific primers separately. Expression of both genes were detected during the different stages of hard tissue formation in the mouse first mandibular molars, but there was some interesting differences in the quantitiy between the two genes. Msx-1 transcripts appeared at the 1 day postnatally, and increase through 3 day, 7 day, then maximally expressed at 14 days postnatally; while Msx-2 mRNA was seen and expressed maximally at the 3 days postnatally, then there was a gradual reduction at 7 days, and 14 days postnatally. The homeobox gene Msx-1, Msx-2 may play a role in the events of the hard tissue formation. The complementary expression pattern of them during the specific stage of hard tissue formation indicates that there may be some functional redundancy between them during the biomineralization.

  18. Hard tissue formation in a porous HA/TCP ceramic scaffold loaded with stromal cells derived from dental pulp and bone marrow.

    NARCIS (Netherlands)

    Zhang, W.; Walboomers, X.F.; Osch, G.J.V.M. van; Dolder, J. van den; Jansen, J.A.

    2008-01-01

    The aim of this study was to compare the ability of hard tissue regeneration of four types of stem cells or precursors under both in vitro and in vivo situations. Primary cultures of rat bone marrow, rat dental pulp, human bone marrow, and human dental pulp cells were seeded onto a porous ceramic

  19. Calcifying Bursitis ischioglutealis: A Case report

    Science.gov (United States)

    Schuh, Alexander; Narayan, Chirag Thonse; Schuh, Ralph; Hönle, Wolfgang

    2011-01-01

    Introduction: The ischiogluteal bursa is an inconstant anatomical finding located between the ischial tuberosity and the gluteus maximus. Ischiogluteal bursitis is a rare disorder. Case Report: We report the case of a 43-year-old female patient with bilateral calcifying ischiogluteal bursitis. The patient had no relevant medical history of systemic illness or major trauma to the buttock. After aspiration of both ischiogluteal bursitis which delievered calcareous deposits and instillation of a mixture of 1cc betamethasone (6 mg) and 4 cc of 1% lidocaine the patient was out of any complaints. Conclusion: Calcifying ischiogluteal bursitis is a rare entity but easily diagnosed on radiographs. Aspiration and local steroid instillation give good relief from symptoms. PMID:27298836

  20. Calcified neurofibroma at the masticator space

    International Nuclear Information System (INIS)

    Fuster, M. J.; Saez, J.; Alonso, S.; Fernandez, F.

    1999-01-01

    Odontogenic infections and invasive tumors or surrounding spaces are the main causes of lesions in the masticator space (MS). Primary tumors, including neurofibromas, are very uncommon within this compartment. We present a calcified neurofibroma at the masticator space. We emphasize the importance of CT to locate lesions at different neck spaces. This method allows to restraint differential diagnoses and to plan surgical approach. (Author) 8 refs

  1. Nodular calcified neurocysticercosis with signs of reactivation

    Energy Technology Data Exchange (ETDEWEB)

    Coeli, Gustavo Nunes Medina; Tiengo, Rodrigo Ribeiro; Silva, Guilherme Carlos da; Silva, Leandro Urquiza Marques Alves da, E-mail: gustavonmc@yahoo.com.br [Department of Radiology and Imaging Diagnosis, Hospital Escola de Itajuba, MG (Brazil); Silva, Afonso Carlos da [Medical Practice, Hospital Escola de Itajuba, MG (Brazil); Fernandes, Jose Otavio Meyer [Clinica Sul Mineira Tomosul and Clinica Magsul, Itajuba, MG (Brazil)

    2012-09-15

    Neurocysticercosis is a disease characterized by the involvement of the central nervous system by the intermediate larval stage of the parasite Taenia solium. The larva degeneration process and the inflammatory reaction of the body cause clinical symptoms. The authors report a case of clinical and radiological reactivation of nodular calcified neurocysticercosis in a patient who was asymptomatic for more than 20 years. Antiparasitic treatment showed a good response (author)

  2. Three-dimensional hard and soft tissue imaging of the human cochlea by scanning laser optical tomography (SLOT.

    Directory of Open Access Journals (Sweden)

    Nadine Tinne

    Full Text Available The present study focuses on the application of scanning laser optical tomography (SLOT for visualization of anatomical structures inside the human cochlea ex vivo. SLOT is a laser-based highly efficient microscopy technique which allows for tomographic imaging of the internal structure of transparent specimens. Thus, in the field of otology this technique is best convenient for an ex vivo study of the inner ear anatomy. For this purpose, the preparation before imaging comprises decalcification, dehydration as well as optical clearing of the cochlea samples in toto. Here, we demonstrate results of SLOT imaging visualizing hard and soft tissue structures with an optical resolution of down to 15 μm using extinction and autofluorescence as contrast mechanisms. Furthermore, the internal structure can be analyzed nondestructively and quantitatively in detail by sectioning of the three-dimensional datasets. The method of X-ray Micro Computed Tomography (μCT has been previously applied to explanted cochlea and is solely based on absorption contrast. An advantage of SLOT is that it uses visible light for image formation and thus provides a variety of contrast mechanisms known from other light microscopy techniques, such as fluorescence or scattering. We show that SLOT data is consistent with μCT anatomical data and provides additional information by using fluorescence. We demonstrate that SLOT is applicable for cochlea with metallic cochlear implants (CI that would lead to significant artifacts in μCT imaging. In conclusion, the present study demonstrates the capability of SLOT for resolution visualization of cleared human cochleae ex vivo using multiple contrast mechanisms and lays the foundation for a broad variety of additional studies.

  3. Whole-field macro- and micro-deformation characteristic of unbound water-loss in dentin hard tissue.

    Science.gov (United States)

    Chen, Zhenning; Nadeau, Bobby; Yu, Kevin; Shao, Xinxing; He, Xiaoyuan; Goh, M Cynthia; Kishen, Anil

    2018-04-06

    High-resolution deformation measurements in a functionally graded hard tissue such as human dentin are essential to understand the unbound water-loss mediated changes and their role in its mechanical integrity. Yet a whole-field, 3-dimensional (3D) measurement and characterization of fully hydrated dentin in both macro- and micro-scales remain to be a challenge. This study was conducted in 2 stages. In stage-1, a stereo-digital image correlation approach was utilized to determine the water-loss and load-induced 3D deformations of teeth in a sagittal section over consecutively acquired frames, from a fully hydrated state to nonhydrated conditions for a period up to 2 hours. The macroscale analysis revealed concentrated residual deformations at the dentin-enamel-junction and the apical regions of root in the direction perpendicular to the dentinal tubules. Significant difference in the localized deformation characteristics was observed between the inner and outer aspects of the root dentin. During quasi-static loadings, further increase in the residual deformation was observed in the dentin. In stage-2, dentin microstructural variations induced by dynamic water-loss were assessed with environmental scanning electron microscopy and atomic force microscopy (AFM), showing that the dynamic water-loss induced distention of dentinal tubules with concave tubular edges, and concurrent contraction of intertubular dentin with convex profile. The findings from the current macro- and micro-scale analysis provided insight on the free-water-loss induced regional deformations and ultrastructural changes in human dentin. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Work Hard / Play Hard

    OpenAIRE

    Burrows, J.; Johnson, V.; Henckel, D.

    2016-01-01

    Work Hard / Play Hard was a participatory performance/workshop or CPD experience hosted by interdisciplinary arts atelier WeAreCodeX, in association with AntiUniversity.org. As a socially/economically engaged arts practice, Work Hard / Play Hard challenged employees/players to get playful, or go to work. 'The game changes you, you never change the game'. Employee PLAYER A 'The faster the better.' Employer PLAYER B

  5. In vitro assessment of the composition and microhardness of hard tissues of oral cavity submitted to gamma irradiation

    International Nuclear Information System (INIS)

    Paredes, Wilber Edison Bernaola

    2017-01-01

    Clinical Radiotherapy is extremely important for the treatment of malignant lesions of the head and neck region, however, exposure to ionizing radiation can lead to systemic or local complications during and after radiation treatment. Among these immediate local complications are the oral cavity xerostomia and the consequent oral mucositis. Regarding late complications produced by radiation, tooth decay of radiation and osteoradionecrosis are included, which are considered dose-dependent lesions, with high incidence in recent decades and difficult to manage, although these appear after completion of treatment and under the influence of local factors. The methodology proposed in this study consists in evaluating the effect of gamma radiation after irradiation of the samples, using the dose used in patients suffering with head and neck cancer. The samples were obtained from human enamel and root dentin; and swine mandibular bone, which were previously polished, and then submitted to the analysis of the initial surface microhardness of all groups. Subsequently, the samples were irradiated in a dose rate of 4 Gy per day, completing a total dose of 72 Gy. Finally, the samples were submitted to surface microhardness analysis after irradiation, which presented statistically significant results from the Student t, ANOVA and Tukey statistical tests referred to the difference of the mean of the initial and final values of each study group with a significant value of p = 0.00 (<0.05). Regarding the morphological analysis in scanning electron microscopy (SEM), the deleterious effect of gamma irradiation was evidenced as structural cracks, breaks and superficial fractures of the analyzed tissues and the biochemical analysis by Attenuated Total Reflection technique using Fourier transform infrared spectroscopy (ATR - FTIR) showed degradation of inorganic components and denaturation of organic compounds; whereby, the effect of gamma irradiation on the hard tissues of the oral

  6. Interdisciplinary approach to enhance the esthetics of maxillary anterior region using soft- and hard-tissue ridge augmentation in conjunction with a fixed partial prosthesis.

    Science.gov (United States)

    Khetarpal, Shaleen; Chouksey, Ajay; Bele, Anand; Vishnoi, Rahul

    2018-01-01

    Favorable esthetics is one of the most important treatment outcomes in dentistry, and to achieve this, interdisciplinary approaches are often required. Ridge deficiencies can be corrected for both, soft- and hard-tissue discrepancies. To overcome such defects, not only a variety of prosthetic options are at our disposal but also several periodontal plastic surgical techniques are available as well. Various techniques have been described and revised, over the year to correct ridge defects. For enhancing soft-tissue contours in the anterior region, the subepithelial connective tissue graft is the treatment of choice. A combination of alloplastic bone graft in adjunct to connective tissue graft optimizes ridge augmentation and minimizes defects. The present case report describes the use of vascular interpositional connective tissue graft in combination with alloplastic bone graft for correction of Seibert's Class III ridge deficiency followed by a fixed partial prosthesis to achieve a better esthetic outcome.

  7. Interdisciplinary approach to enhance the esthetics of maxillary anterior region using soft- and hard-tissue ridge augmentation in conjunction with a fixed partial prosthesis

    Directory of Open Access Journals (Sweden)

    Shaleen Khetarpal

    2018-01-01

    Full Text Available Favorable esthetics is one of the most important treatment outcomes in dentistry, and to achieve this, interdisciplinary approaches are often required. Ridge deficiencies can be corrected for both, soft- and hard-tissue discrepancies. To overcome such defects, not only a variety of prosthetic options are at our disposal but also several periodontal plastic surgical techniques are available as well. Various techniques have been described and revised, over the year to correct ridge defects. For enhancing soft-tissue contours in the anterior region, the subepithelial connective tissue graft is the treatment of choice. A combination of alloplastic bone graft in adjunct to connective tissue graft optimizes ridge augmentation and minimizes defects. The present case report describes the use of vascular interpositional connective tissue graft in combination with alloplastic bone graft for correction of Seibert's Class III ridge deficiency followed by a fixed partial prosthesis to achieve a better esthetic outcome.

  8. Computed Tomography Features of Benign and Malignant Calcified Thyroid Nodules: A Single-Center Study.

    Science.gov (United States)

    Kim, Donghyun; Kim, Dong Wook; Heo, Young Jin; Baek, Jin Wook; Lee, Yoo Jin; Park, Young Mi; Baek, Hye Jin; Jung, Soo Jin

    No previous studies have investigated thyroid calcification on computed tomography (CT) quantitatively by using Hounsfield unit (HU) values. This study aimed to analyze quantitative HU values of thyroid calcification on preoperative neck CT and to assess the characteristics of benign and malignant calcified thyroid nodules (CTNs). Two hundred twenty patients who underwent neck CT before thyroid surgery from January 2015 to June 2016 were included. On soft-tissue window CT images, CTNs with calcified components of 3 mm or larger in minimum diameter were included in this study. The HU values and types of CTNs were determined and analyzed. Of 61 CTNs in 49 patients, there were 42 malignant nodules and 19 benign nodules. The mean largest diameter of the calcified component was 5.3 (2.5) mm (range, 3.1-17.1 mm). A statistically significant difference was observed in the HU values of calcified portions between benign and malignant CTNs, whereas there was no significant difference in patient age or sex or in the size, location, or type of each CTN. Of the 8 CTNs with pure calcification, 3 exhibited a honeycomb pattern on bone window CT images, and these 3 CTNs were all diagnosed as papillary thyroid carcinoma on histopathological examination. Hounsfield unit values of CTNs may be helpful for differentiating malignancy from benignity.

  9. Supraspinatus Intramuscular Calcified Hematoma or Necrosis Associated with Tendon Tear

    Directory of Open Access Journals (Sweden)

    Alexandre Lädermann

    2015-01-01

    Full Text Available Introduction. Rotator cuff intramuscular calcification is a rare condition usually caused by heterotopic ossification and myositis ossificans. Case Presentation. We describe a patient with voluminous calcified mass entrapped in supraspinatus muscle associated with corresponding tendon tear. Histological examination corresponded to a calcified hematoma or necrosis. Patient was surgically managed with open excision of the calcified hematoma and rotator cuff arthroscopic repair. At 6 months, supraspinatus muscle was healed, and functional outcome was good. Discussion and Conclusion. We hypothesized that supraspinatus intramuscular calcified hematoma was responsible for mechanical stress on the tendon. This association has never been described.

  10. Calcifying tendinitis of the rotator cuff with cortical bone erosion

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Roxanne; Kim, David H.; Millett, Peter J. [Harvard Medical School, Brigham and Women' s Hospital, Boston, Massachusetts (United States); Weissman, Barbara N. [Harvard Medical School, Brigham and Women' s Hospital, Boston, Massachusetts (United States); Brigham and Women' s Hospital, Department of Radiology, Musculoskeletal Division, Boston (United States)

    2004-10-01

    Calcifying tendinitis occurs most commonly in the rotator cuff tendons, particularly involving the supraspinatus tendon insertion, and is often asymptomatic. Cortical erosion secondary to calcifying tendinitis has been reported in multiple locations, including in the rotator cuff tendons. We present a pathologically proven case of symptomatic calcifying tendinitis involving the infraspinatus tendon with cortical erosion with correlative radiographic, CT, and MR findings. The importance of considering this diagnosis when evaluating lytic lesions of the humerus and the imaging differential diagnosis of calcifying tendinitis and cortical erosion are discussed. (orig.)

  11. Calcifying tendinitis of the rotator cuff with cortical bone erosion

    International Nuclear Information System (INIS)

    Chan, Roxanne; Kim, David H.; Millett, Peter J.; Weissman, Barbara N.

    2004-01-01

    Calcifying tendinitis occurs most commonly in the rotator cuff tendons, particularly involving the supraspinatus tendon insertion, and is often asymptomatic. Cortical erosion secondary to calcifying tendinitis has been reported in multiple locations, including in the rotator cuff tendons. We present a pathologically proven case of symptomatic calcifying tendinitis involving the infraspinatus tendon with cortical erosion with correlative radiographic, CT, and MR findings. The importance of considering this diagnosis when evaluating lytic lesions of the humerus and the imaging differential diagnosis of calcifying tendinitis and cortical erosion are discussed. (orig.)

  12. The prevalence, pattern and clinical presentation of developmental dental hard-tissue anomalies in children with primary and mix dentition from Ile-Ife, Nigeria

    OpenAIRE

    Temilola, Dada Oluwaseyi; Folayan, Morenike Oluwatoyin; Fatusi, Olawunmi; Chukwumah, Nneka Maureen; Onyejaka, Nneka; Oziegbe, Elizabeth; Oyedele, Titus; Kolawole, Kikelomo Adebanke; Agbaje, Hakeem

    2014-01-01

    Background The study of dental anomalies is important because it generates information that is important for both the anthropological and clinical management of patients. The objective of this study is to determine the prevalence and pattern of presentation of dental hard-tissue developmental anomalies in the mix dentition of children residing in Ile-Ife, a suburban region of Nigeria. Methods Information on age, sex and socioeconomic status was collected from 1,036 children aged four months t...

  13. Atypical adult non-calcified pilomatricoma

    International Nuclear Information System (INIS)

    Masih, S.; Gentili, A.; Sorenson, S.M.; Seeger, L.L.

    2000-01-01

    We present a rare case of a non-calcified pilomatricoma in a 67-year-old man. This tumor was extremely large in size, and its location, in the lower extremity, was very unusual. The clinical, radiographic, and histopathological features are described in detail. The role of magnetic resonance imaging (MRI) in the diagnosis of this entity is discussed. Definite internal reticulations and septations were observed. A possible explanation for this observation is that the high signal intensity reticulations may represent edematous stroma surrounding basaloid cells. (orig.)

  14. Dental hard tissue modification and removal using sealed transverse excited atmospheric-pressure lasers operating at lambda=9.6 and 10.6 um

    Science.gov (United States)

    Fried, Daniel; Ragadio, Jerome N.; Akrivou, Maria; Featherstone, John D.; Murray, Michael W.; Dickenson, Kevin M.

    2001-04-01

    Pulsed CO2 lasers have been shown to be effective for both removal and modification of dental hard tissue for the treatment of dental caries. In this study, sealed transverse excited atmospheric pressure (TEA) laser systems optimally tuned to the highly absorbed 9.6 micrometers wavelength were investigated for application on dental hard tissue. Conventional TEA lasers produce an initial high energy spike at the beginning of the laser pulse of submicrosecond duration followed by a long tail of about 1 - 4 microsecond(s) . The pulse duration is well matched to the 1 - 2 microsecond(s) thermal relaxation time of the deposited laser energy at 9.6 micrometers and effectively heats the enamel to the temperatures required for surface modification at absorbed fluences of less than 0.5 J/cm2. Thus, the heat deposition in the tooth and the corresponding risk of pulpal necrosis from excessive heat accumulation is minimized. At higher fluences, the high peak power of the laser pulse rapidly initiates a plasma that markedly reduces the ablation rate and efficiency, severely limiting applicability for hard tissue ablation. By lengthening the laser pulse to reduce the energy distributed in the initial high energy spike, the plasma threshold can be raised sufficiently to increase the ablation rate by an order of magnitude. This results in a practical and efficient CO2 laser system for caries ablation and surface modification.

  15. Dental hard tissue modification and removal using sealed TEA lasers operating at λ=9.6 and 10.6 μm

    Science.gov (United States)

    Fried, Daniel; Murray, Michael W.; Featherstone, John D. B.; Akrivou, Maria; Dickenson, Kevin M.; Duhn, Clifford W.; Ojeda, Orlando P.

    1999-05-01

    Pulsed CO2 lasers have been shown to be effective for both removal and modification of dental hard tissue for the treatment of dental caries. In this study, sealed TEA laser systems optimally tuned to the highly absorbed 9.6 μm wavelength were investigated for application on dental hard tissue. Conventional TEA lasers produce a laser pulse wit a 100-200 ns gain switched spike followed by a long tail of about 1-4 μs in duration. the pulse duration is well matched to the 1-2 μs thermal relaxation time of the deposited laser energy at 9.6 μm and effectively heats the enamel to temperatures required for surface modification for caries prevention at absorbed fluences of less than 0.5 J/cm2. Thus, the heat deposition in the tooth and the corresponding risk, of pulpal necrosis form excessive heat accumulation is minimized. At higher fluences the high peak power of the gain-switched spike rapidly initiates a plasma that markedly reduces the ablation rate and efficiency, severely limiting applicability for hard tissue ablation. By slightly stretching the pulse to reduce the energy distributed in the initial 100-200 ns of the laser pulse, the plasma threshold can be raised sufficiently to increase the ablation rate by an order of magnitude. This results in a practical and efficient CO2 laser system for caries ablation and surface modification.

  16. Hard and Soft Tissue Changes Following Maxillary Distraction Osteogenesis and Mandibular Setback with Bilateral Sagittal Split Osteotomy.

    Science.gov (United States)

    Bawane, Shilpa S; Andrade, Neelam N

    2016-12-01

    (1) To highlight the role of intraoral submerged device in distraction osteogenesis (DO) of patients requiring two jaw surgeries for the correction of severe developmental maxillary hypoplasia (MH) and mandibular prognathism (MP) (2) To analyse the hard and soft tissue changes following maxillary DO and mandibular setback with bilateral sagittal split osteotomy (BSSO) in patients with severe MH and MP requiring two jaw surgeries. During the period Jan 2004 to Dec 2006, five patients with severe developmental MH along with MP were treated. In 1st stage maxillary distraction was done. Distraction started on 6th postoperative day, 1 mm distraction was carried out for 10-15 days on either side. Serial radiographs were taken immediate postoperative period for baseline comparison, post-distraction and at the end of distraction. After a period of 3-4 months of distraction 2nd stage was done. In 2nd stage, mandibular setback was done with BSSO and distractors were removed under general anesthesia. Radiographs were taken immediately and at 4 months post-operatively. Cephalometric tracings were carried out preoperatively, post DO and finally after mandibular setback with BSSO. The mean horizontal movement of maxilla was 11.4 mm at ANS and 9.6 mm at A point. Upper incisor edge was advanced by 8.8 mms. SNA increased by 8.4° and SNB decreased by 4.6°. Nasal projection advanced by 4°. Nasolabial angle normalized in all patients, mean change achieved was 10.8°. Upper lip moved forward by 5.4 mm. Lower lip moved backward by 5.4 mm. Mandible positioned backward by 4 mm at B point. No vertical change occurred in the position of A, ANS and upper incisor edges. Mean increase in skeletal angle of convexity was 26.4°. Concave profile was significantly changed to convex in all patients. Maxillary DO and mandibular setback with BSSO was associated with improved facial balance and esthetics.

  17. Calcified trichinosis of pectoral muscle: mammographic appearance

    International Nuclear Information System (INIS)

    Apesteguia, L.; Murillo, A.; Biurrun, J.; Garcia-Rostan, G.; Reta, A.; Dominguez, F.

    1995-01-01

    By mammographic screening we had detected six asymptomatic women who showed numerious tiny and well-delineated round to ovoid microcalcification superimposed on pectoral shadows, in the oblique medio-lateral (OML) view. Our objective was to achieve a better evaluation of these calcifications and investigate their origin. Magnified mammograms of pectoral muscles were done in the six women. A questionnaire concerning the patients' diets was also administered. Trichinella antibody titres were quantified by sero-agglutination. Microcalcifications within pectoral muscle fibres were demonstrated in all the cases. Five women admitted to having eaten home-made pork products in the past. One of them showed a slightly elevated antibody titre. We confirmed the suspected diagnosis of calcified trichinosis by a surgical biopsy of the pectoral muscle performed on one of the patients. We conclude that chronic calcified trichinosis of the pectoral muscle can be visualised in the OML view of a conventional mammogram. The mammographic appearance of this entity is very characteristic and biopsy would not be required for its diagnosis in the future. (orig.)

  18. Calcified trichinosis of pectoral muscle: mammographic appearance

    Energy Technology Data Exchange (ETDEWEB)

    Apesteguia, L. [Servicio de Radiologia, Hospital Virgen del Camino, Pamplona (Spain); Murillo, A. [Servicio de Radiologia, Hospital Virgen del Camino, Pamplona (Spain); Biurrun, J. [Servicio de Radiologia, Hospital Virgen del Camino, Pamplona (Spain); Garcia-Rostan, G. [Servicio Anatomia Patologica, Hospital Virgen del Camino, Pamplona (Spain); Reta, A. [Servicio de Analisis Clinicos, Hospital Virgen del Camino, Pamplona (Spain); Dominguez, F. [Servicio Cirugia, Hospital Virgen del Camino, Pamplona (Spain)

    1995-12-31

    By mammographic screening we had detected six asymptomatic women who showed numerious tiny and well-delineated round to ovoid microcalcification superimposed on pectoral shadows, in the oblique medio-lateral (OML) view. Our objective was to achieve a better evaluation of these calcifications and investigate their origin. Magnified mammograms of pectoral muscles were done in the six women. A questionnaire concerning the patients` diets was also administered. Trichinella antibody titres were quantified by sero-agglutination. Microcalcifications within pectoral muscle fibres were demonstrated in all the cases. Five women admitted to having eaten home-made pork products in the past. One of them showed a slightly elevated antibody titre. We confirmed the suspected diagnosis of calcified trichinosis by a surgical biopsy of the pectoral muscle performed on one of the patients. We conclude that chronic calcified trichinosis of the pectoral muscle can be visualised in the OML view of a conventional mammogram. The mammographic appearance of this entity is very characteristic and biopsy would not be required for its diagnosis in the future. (orig.)

  19. Aortic calcified particles modulate valvular endothelial and interstitial cells.

    Science.gov (United States)

    van Engeland, Nicole C A; Bertazzo, Sergio; Sarathchandra, Padmini; McCormack, Ann; Bouten, Carlijn V C; Yacoub, Magdi H; Chester, Adrian H; Latif, Najma

    Normal and calcified human valve cusps, coronary arteries, and aortae harbor spherical calcium phosphate microparticles of identical composition and crystallinity, and their role remains unknown. The objective was to examine the direct effects of isolated calcified particles on human valvular cells. Calcified particles were isolated from healthy and diseased aortae, characterized, quantitated, and applied to valvular endothelial cells (VECs) and interstitial cells (VICs). Cell differentiation, viability, and proliferation were analyzed. Particles were heterogeneous, differing in size and shape, and were crystallized as calcium phosphate. Diseased donors had significantly more calcified particles compared to healthy donors (Pinnocent bystanders but induce a phenotypical and pathological change of VECs and VICs characteristic of activated and pathological cells. Therapy tailored to reduce these calcified particles should be investigated. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. 针对组织工程多孔生物陶瓷的组织学技术优化探讨%Technique improvement of hard tissue slicing of bioceramic scaffold materials applied in bone tissue engineering

    Institute of Scientific and Technical Information of China (English)

    李林; 智伟; 桑力; 张成栋; 李金雨; 张聪; 娄延举; 夏天; 翁杰

    2013-01-01

    目的 改进硬组织切片技术以适应生物陶瓷材料在骨组织工程中的研究.方法 探索硬组织切片的厚度、漂片温度、裱片方法、烤片温度和时间的最佳组合,针对阳离子防脱载玻片的使用条件进行反复比较,通过改进操作流程中的关键技术和需避免的问题,摸索出阳离子载玻片在硬组织切片裱片中的最佳应用条件,克服了硬组织切片制作技术中标本易破碎、切片易脱落及染色时染料容易吸附的缺点.结果 通过技术探索与改进,生物陶瓷支架材料体内植入后的类骨修复体标本的硬组织切片能保持其杂化后的组织结构与比较完整的材料结构,可进行Masson三色染色、苏木精-伊红(HE)及甲苯胺蓝染色.染色后镜下观察显示支架内杂化生长的组织结构完整、细胞形态清晰、切片质量好、生物陶瓷支架脱片少.荧光显微镜可观察到类骨修复体钙沉积现象完整.结论 改善了传统硬组织切片技术处理生物陶瓷材料时易于破坏组织-材料结构的缺点.改进的硬组织切片技术适应生物陶瓷材料在骨组织工程领域研究.%Objective Purpose To improve the hard tissue slicing technology to adapt to the study of the bioceramic materials in bone tissue engineering.Methods Purpose To improve the hard tissue slicing technology to adapt to the study of the bioceramic materials in bone tissue engineering.Results The improved techniques in hard tissue slicing could keep the morphosis and structure of hybrid tissues,and easily stain with Masson,HE and toluidine blue.The stained hard tissue slicing had an intact tissue structure,clear cell form,good slicing quality,little shedding.Fluorescence microscope showed an intact calcium deposition of homologous bone restoration.Conclusion The method overcome the shortcomings of easy to destroy the tissue-material structure happened in the traditional hard tissue slicing of bioceramic materials

  1. Combined effect of fluoride and 2,3,7,8-tetrachlorodibenzo-p-dioxin on mouse dental hard tissue formation in vitro.

    Science.gov (United States)

    Salmela, Eija; Lukinmaa, Pirjo-Liisa; Partanen, Anna-Maija; Sahlberg, Carin; Alaluusua, Satu

    2011-08-01

    Fluoride interferes with enamel matrix secretion and mineralization and dentin mineralization. The most toxic dioxin congener, 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), also impairs dental hard tissue formation and mineralization in vitro and in vivo. Our aim was to investigate in vitro whether the combined effect of sodium fluoride (NaF) and TCDD on dental hard tissue formation is potentiative. For this purpose, mandibular first and second molar tooth germs of E18 mouse embryos were cultured for 5-12 days with NaF and TCDD alone at various concentrations (2.5, 5, 10, 12.5, 15, and 20 μM and 5, 10, 12.5, and 15 nM, respectively) to determine the highest concentrations, which alone cause no or negligible effects. Morphological changes were studied from the whole tooth photographs and histological tissue sections. The concentrations found were 15 μM for NaF and 10 nM for TCDD. While at these concentrations, the effects of NaF and TCDD alone were barely detectable, the effect of simultaneous exposure on dentin and enamel formation was overt; mineralization of predentin to dentin and enamel matrix secretion and mineralization were impaired. Immunohistochemical analysis revealed that the combined exposure modified amelogenin expression by odontoblasts. Morphology of ameloblasts and the expression of amelogenin indicated that ameloblasts were still secretory. The results show that NaF and TCDD have potentiative, harmful effects on the formation of dental hard tissues. Since children can be exposed to subclinical levels of fluoride and dioxins during early childhood, coincidently with mineralization of the first permanent teeth, this finding may have clinical significance.

  2. Investigation of composition and structure of spongy and hard bone tissue using FTIR spectroscopy, XRD and SEM

    Science.gov (United States)

    Al-Akhras, M.-Ali H.; Hasan Qaseer, M. K.; Albiss, B. A.; Alebrhim, M. Anwar; Gezawa, Umar S.

    2018-02-01

    Valuable structural and chemical features can be obtained for spongy and hard bone by infrared spectroscopy and X-ray diffraction. A better understanding of chemical and structural differences between spongy and hard bone is a very important contributor to bone quality. Our data according to IR data showed that the collagen cross-links occurred to be higher in spongy bone, and crystallinity was lower in spongy bone. Deconvolution of the infrared band near 870 cm-1 reveals evidence for A2-type carbonate substitution on hydroxyapatite of spongy bone in addition to the A and B type carbonate substitution that are also found in hard bone. IR and XRD data confirmed the results of each other since full width at half maximum of 002-apatite pattern of XRD showed that the crystallinity was lower in spongy bone. The microstructure was examined by using scanning electron microscope and the result showed that the lattice of thin threads in spongy bone and is less dense than hard bone.

  3. Kappa-splints application for the treatment of pathological dental hard tissues abrasion in combination with dentition defects and dentition deformations

    Directory of Open Access Journals (Sweden)

    Svitlana Petrishin

    2017-03-01

    2. After studying the movements of conventional hinge axis in articulate heads of TMJ with the help of condylograph «Cadiax Compact» and eliminating the symptoms of stress in masticatory muscles of the patients with occlusive disorders at pathological dental hard tissues abrasion, it is the gradual application of a kappa-splints set, made of hard transparent plates of Ercodent Ercodur material (Germany with a thickness of 1.0 to 5.0 mm, which allows prevention of further tooth wear, normalization of occlusive correlations of the jaws, separating a bite with optimum thickness throughout the dentition, thus the lower jaw takes a position at which the state of functional equilibrium of the entire dentition is restored.

  4. Proteomic analysis of the organic matrix of the abalone Haliotis asinina calcified shell

    Directory of Open Access Journals (Sweden)

    Degnan Bernard M

    2010-11-01

    Full Text Available Abstract Background The formation of the molluscan shell is regulated to a large extent by a matrix of extracellular macromolecules that are secreted by the shell forming tissue, the mantle. This so called "calcifying matrix" is a complex mixture of proteins and glycoproteins that is assembled and occluded within the mineral phase during the calcification process. While the importance of the calcifying matrix to shell formation has long been appreciated, most of its protein components remain uncharacterised. Results Recent expressed sequence tag (EST investigations of the mantle tissue from the tropical abalone (Haliotis asinina provide an opportunity to further characterise the proteins in the shell by a proteomic approach. In this study, we have identified a total of 14 proteins from distinct calcified layers of the shell. Only two of these proteins have been previously characterised from abalone shells. Among the novel proteins are several glutamine- and methionine-rich motifs and hydrophobic glycine-, alanine- and acidic aspartate-rich domains. In addition, two of the new proteins contained Kunitz-like and WAP (whey acidic protein protease inhibitor domains. Conclusion This is one of the first comprehensive proteomic study of a molluscan shell, and should provide a platform for further characterization of matrix protein functions and interactions.

  5. Association between dental pulp stones and calcifying nanoparticles.

    Science.gov (United States)

    Zeng, Jinfeng; Yang, Fang; Zhang, Wei; Gong, Qimei; Du, Yu; Ling, Junqi

    2011-01-07

    The etiology of dental pulp stones, one type of extraskeletal calcification disease, remains elusive to date. Calcifying nanoparticles (CNPs), formerly referred to as nanobacteria, were reported to be one etiological factor in a number of extraskeletal calcification diseases. We hypothesized that CNPs are involved in the calcification of the dental pulp tissue, and therefore investigated the link between CNPs and dental pulp stones. Sixty-five freshly collected dental pulp stones, each from a different patient, were analyzed. Thirteen of the pulp stones were examined for the existence of CNPs in situ by immunohistochemical staining (IHS), indirect immunofluorescence staining (IIFS), and transmission electron microscope (TEM). The remaining 52 pulp stones were used for isolation and cultivation of CNPs; the cultured CNPs were identified and confirmed via their shape and growth characteristics. Among the dental pulp stones examined in situ, 84.6% of the tissue samples staines positive for CNPs antigen by IHS; the corresponding rate by IIFS was 92.3 %. In 88.2% of the cultured samples, CNPs were isolated and cultivated successfully. The CNPs were visible under TEM as 200-400 nm diameter spherical particles surrounded by a compact crust. CNPs could be detected and isolated from a high percentage of dental pulp stones, suggesting that CNPs might play an important role in the calcification of dental pulp.

  6. Hard electronics; Hard electronics

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    Hard material technologies were surveyed to establish the hard electronic technology which offers superior characteristics under hard operational or environmental conditions as compared with conventional Si devices. The following technologies were separately surveyed: (1) The device and integration technologies of wide gap hard semiconductors such as SiC, diamond and nitride, (2) The technology of hard semiconductor devices for vacuum micro- electronics technology, and (3) The technology of hard new material devices for oxides. The formation technology of oxide thin films made remarkable progress after discovery of oxide superconductor materials, resulting in development of an atomic layer growth method and mist deposition method. This leading research is expected to solve such issues difficult to be easily realized by current Si technology as high-power, high-frequency and low-loss devices in power electronics, high temperature-proof and radiation-proof devices in ultimate electronics, and high-speed and dense- integrated devices in information electronics. 432 refs., 136 figs., 15 tabs.

  7. The prevalence, pattern and clinical presentation of developmental dental hard-tissue anomalies in children with primary and mix dentition from Ile-Ife, Nigeria.

    Science.gov (United States)

    Temilola, Dada Oluwaseyi; Folayan, Morenike Oluwatoyin; Fatusi, Olawunmi; Chukwumah, Nneka Maureen; Onyejaka, Nneka; Oziegbe, Elizabeth; Oyedele, Titus; Kolawole, Kikelomo Adebanke; Agbaje, Hakeem

    2014-10-16

    The study of dental anomalies is important because it generates information that is important for both the anthropological and clinical management of patients. The objective of this study is to determine the prevalence and pattern of presentation of dental hard-tissue developmental anomalies in the mix dentition of children residing in Ile-Ife, a suburban region of Nigeria. Information on age, sex and socioeconomic status was collected from 1,036 children aged four months to 12 years through a household survey. Clinical examination was conducted to assess the presence of dental anomalies. Associations between age, sex, socioeconomic status, prevalence, and pattern of presentation of the developmental hard-tissue dental anomalies were determined. Two hundred and seventy six (26.6%) children had dental anomalies. Of these, 23.8% had one anomaly, 2.5% had two anomalies, and 0.3% had more than two anomalies. Of the children with anomalies, 49.3%were male, 50.7%were female, and 47.8%, 28.6% and 23.6% were children from low, middle and high socioeconomic classes, respectively. More anomalies were seen in permanent than primary dentition. Anomalies of tooth structure were most prevalent (16.1%); anomalies which affect tooth number were least prevalent (1.3%). Dens evaginatus, peg-shaped lateral, macrodontia, and talon cusp were more prevalent in the permanent dentition, and dens evaginatus peg-shaped lateral and macrodontia were more prevalent in the maxilla. There were significantly more macrodontia anomalies in males and in children of high socioeconomic status. This large survey of dental hard-tissue anomalies found in the primary dentition and mixed dentition of children in Nigeria provides anthropological and clinical data that may aid the detection and management of dental problems of children in Nigeria.

  8. Thermodynamic basis for evolution of apatite in calcified tissues (Invited)

    Science.gov (United States)

    Navrotsky, A.; Drouet, C.; Rollin-Martinet, S.; Champion, E.; Grossin, D.

    2013-12-01

    Bone remodeling and tooth enamel maturation are biological processes which alter the physico-chemical features of biominerals with time. However, although the ubiquity of bone remodeling is clear, why is well crystallized bone mineral systematically replaced by immature nanocrystalline inorganic material? In enamel, a clear evolution is also seen from the first mineral formed during the secretory stage to its mature well crystalline form, which then changes little in the adult tooth. This contribution provides the thermodynamic basis underlying these biological processes. We determined the energetics of biomimetic apatites corresponding to an increasing degree of maturation. Our data point out the progressive evolution of the enthalpy (ΔHf°) and free energy (ΔGf°) of formation toward more negative values upon maturation. Entropy contributions to ΔGf° values are small compared to enthalpy contributions. ΔHf° varies from -12058.9 × 12.2 to -12771.0 × 21.4 kJ/mol for maturation times increasing from 20 min to 3 weeks, approaching the value for stoichiometric hydroxyapatite, -13431.0 × 22.7 kJ/mol. Apatite thermodynamic stability increases as its composition moved toward stoichiometry. These findings imply diminishing aqueous solubility of calcium and phosphate ions as well as decreased surface reactivity. Such thermodynamically-driven maturation is favorable for enamel maturation since this biomineral must resist external aggressions such as contact with acids. In contrast, maintaining a metastable highly reactive and soluble form of apatite is essential to the effective participation of bone as a source of calcium and phosphate for homeostasis. Therefore our data strongly suggest that, far from being trivial, the intrinsic thermodynamic properties of apatite represent a critical driving force for continuous bone remodeling, in contrast to current views favoring a purely biologically driven cycle. These thermodynamic data may prove helpful in other domains relating, for example, to apatite-based biomaterials development or in (geo)microbiology.

  9. Digital dissection - using contrast-enhanced computed tomography scanning to elucidate hard- and soft-tissue anatomy in the Common Buzzard Buteo buteo.

    Science.gov (United States)

    Lautenschlager, Stephan; Bright, Jen A; Rayfield, Emily J

    2014-04-01

    Gross dissection has a long history as a tool for the study of human or animal soft- and hard-tissue anatomy. However, apart from being a time-consuming and invasive method, dissection is often unsuitable for very small specimens and often cannot capture spatial relationships of the individual soft-tissue structures. The handful of comprehensive studies on avian anatomy using traditional dissection techniques focus nearly exclusively on domestic birds, whereas raptorial birds, and in particular their cranial soft tissues, are essentially absent from the literature. Here, we digitally dissect, identify, and document the soft-tissue anatomy of the Common Buzzard (Buteo buteo) in detail, using the new approach of contrast-enhanced computed tomography using Lugol's iodine. The architecture of different muscle systems (adductor, depressor, ocular, hyoid, neck musculature), neurovascular, and other soft-tissue structures is three-dimensionally visualised and described in unprecedented detail. The three-dimensional model is further presented as an interactive PDF to facilitate the dissemination and accessibility of anatomical data. Due to the digital nature of the data derived from the computed tomography scanning and segmentation processes, these methods hold the potential for further computational analyses beyond descriptive and illustrative proposes. © 2013 The Authors. Journal of Anatomy published by John Wiley & Sons Ltd on behalf of Anatomical Society.

  10. Calcified subdural hematoma associated with hypertensive intracerebral hemorrhage

    International Nuclear Information System (INIS)

    Ishige, Naoki; Sunami, Kenro; Sato, Akira; Watanabe, Osamu

    1984-01-01

    A case of calcified subdural hematoma associated with hypertensive intracerebral hemorrhage is reported. A left frontal subdural hematoma with left putaminal hemorrhage was incidentally found when a CT scan was performed to evaluate right hemiparesis and aphasia in a 55-year-old man. The putaminal hemorrhage was not very extensive, but his clinical symptoms were rather serious. Not only the putaminal hemorrhage, but also the presence of the calcified subdural hematoma was considered to have caused his clinical deterioration. The subtotal removal of the calcified subdural hematoma brought about a good result. (author)

  11. Calcifying epithelial odontogenic cyst with odontome in left mandible

    Directory of Open Access Journals (Sweden)

    R Kamala

    2009-01-01

    Full Text Available Calcifying epithelial odontogenic cyst is a mixed odontogenic benign tumor but most of the cases present cystic characteristics. We present a case report of calcifying epithelial odontogenic cyst with odontoma in a 20-year-old male who presented with a painless unilateral swelling of the jaw. The lesion involved an impacted 37 which was displaced to the lower border of the mandible and a calcified mass that was within the cystic lesion that was recognized as odontoma. The lesion was surgically removed along with 36 and 37 was allowed to erupt.

  12. WHO water quality standards Vs Synergic effect(s) of fluoride, heavy metals and hardness in drinking water on kidney tissues

    Science.gov (United States)

    Wasana, Hewa M. S.; Perera, Gamage D. R. K.; Gunawardena, Panduka De S.; Fernando, Palika S.; Bandara, Jayasundera

    2017-02-01

    Despite WHO standards, waterborne diseases among the human being are rising alarmingly. It is known that the prolong exposure to contaminated water has major impact on public health. The effect of chemical contaminations in drinking water on human being is found to be chronic rather than acute and hence can be defined “consumption of contaminated drinking water could be a silent killer”. As the WHO recommended water quality standards are only for individual element and synergic effects of trace metals and anions have not been considered, investigation of synergic effects of trace metals and anions and their effect on human being is of prime important research. By an animal trial, we investigated the synergic effect(s) of heavy metals, aluminium, arsenic, fluoride and hardness in drinking water on kidney tissues of mice. Our investigation strongly suggests existing of a synergic effect especially among Cd, F and hardness of water which could lead to severe kidney damage in mice, even at WHO maximum recommended levels. Hence, the synergic effect(s) of trace metals, fluoride and hardness present in drinking water should be investigated meticulously when stipulating the water quality at WHO maximum recommended levels.

  13. Experimental study of the effect of Nd:YAG laser on dental hard tissues: comparison between multi-pulse and free-generation emission code

    International Nuclear Information System (INIS)

    Carballosa Amor, A.; Tellez Jimenez, H.; Ponce Flores, E.; Flores Reyes, T.

    2016-01-01

    The aim of this study is to compare and contrast the morphological changes on dental hard tissue when irradiated with a Nd: YAG laser both on multi-pulse mode, with a Q: Switch of Cr: YAG passive, and on free generation mode. The experimental sample consisted of 6 healthy third molars which were divided equally and randomly between the two emission methods. The depths of each perforation were measured by optical coherence tomography (OCT). It was noted that, despite being less energy in the multi-pulse mode, the first three shots in this achieved deeper cavities than the ones on the free generation mode. Also, less damage to surrounding tissue were obtained on multi-pulse mode. (Author)

  14. Soft and Hard Tissue Changes Following Immediate Placement or Immediate Restoration of Single-Tooth Implants in the Esthetic Zone: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Yan, Qi; Xiao, Li-Qun; Su, Mei-Ying; Mei, Yan; Shi, Bin

    This systematic review aimed to compare immediate protocols with conventional protocols of single-tooth implants in terms of changes in the surrounding hard and soft tissue in the esthetic area. Electronic and manual searches were performed in PubMed, EMBASE, Cochrane, and other data systems for research articles published between January 2001 and December 2014. Only randomized controlled trials (RCTs) reporting on hard and or soft tissue characteristics following a single-tooth implant were included. Based on the protocol used in each study, the included studies were categorized into three groups to assess the relationships between the factors and related esthetic indexes. Variables such as marginal bone level changes (mesial, distal, and mean bone level), peri-implant soft tissue changes (papilla level, midbuccal mucosa, and probing depth), and other esthetic indices were taken into consideration. The data were analyzed using RevMan version 5.3, Stata 12, and GRADEpro 3.6.1 software. A total of 13 RCTs met the inclusion criteria. Four studies examined immediate implant placement, five studies examined immediate implant restoration, and four studies examined immediate loading. Comparing the bone level changes following immediate and conventional restoration, no significant differences were found in the bone level of the mesial site (standard mean difference [SMD] = -0.04 mm; 95% confidence interval [CI]: -0.25 to 0.17 mm), the distal site (SMD = -0.15 mm; 95% CI: -0.38 to 0.09 mm), and the mean bone level changes (SMD = 0.05 mm; 95% CI: -0.18 to 0.27 mm). The difference in the marginal bone level changes between immediate and conventional loading was also not statistically significant (SMD = -0.05 mm; 95% CI: -0.15 to 0.06 mm for the mesial site and SMD = -0.02 mm; 95% CI: -0.09 to 0.05 mm for the distal site). Soft tissue changes following immediate and conventional restoration reported no significant differences in the papillae level of the mesial site (SMD = 0

  15. Noninvasive computerized scanning method for the correlation between the facial soft and hard tissues for an integrated three-dimensional anthropometry and cephalometry.

    Science.gov (United States)

    Galantucci, Luigi Maria; Percoco, Gianluca; Lavecchia, Fulvio; Di Gioia, Eliana

    2013-05-01

    The article describes a new methodology to scan and integrate facial soft tissue surface with dental hard tissue models in a three-dimensional (3D) virtual environment, for a novel diagnostic approach.The facial and the dental scans can be acquired using any optical scanning systems: the models are then aligned and integrated to obtain a full virtual navigable representation of the head of the patient. In this article, we report in detail and further implemented a method for integrating 3D digital cast models into a 3D facial image, to visualize the anatomic position of the dentition. This system uses several 3D technologies to scan and digitize, integrating them with traditional dentistry records. The acquisitions were mainly performed using photogrammetric scanners, suitable for clinics or hospitals, able to obtain high mesh resolution and optimal surface texture for the photorealistic rendering of the face. To increase the quality and the resolution of the photogrammetric scanning of the dental elements, the authors propose a new technique to enhance the texture of the dental surface. Three examples of the application of the proposed procedure are reported in this article, using first laser scanning and photogrammetry and then only photogrammetry. Using cheek retractors, it is possible to scan directly a great number of dental elements. The final results are good navigable 3D models that integrate facial soft tissue and dental hard tissues. The method is characterized by the complete absence of ionizing radiation, portability and simplicity, fast acquisition, easy alignment of the 3D models, and wide angle of view of the scanner. This method is completely noninvasive and can be repeated any time the physician needs new clinical records. The 3D virtual model is a precise representation both of the soft and the hard tissue scanned, and it is possible to make any dimensional measure directly in the virtual space, for a full integrated 3D anthropometry and

  16. Effects of surface hydrophilicity and microtopography on early stages of soft and hard tissue integration at non-submerged titanium implants: an immunohistochemical study in dogs.

    Science.gov (United States)

    Schwarz, Frank; Ferrari, Daniel; Herten, Monika; Mihatovic, Ilja; Wieland, Marco; Sager, Martin; Becker, Jürgen

    2007-11-01

    The aim of the present study was to investigate the effects of surface hydrophilicity and microtopography on soft and hard tissue integration at non-submerged titanium implants. Implantation of conventional sand-blasted large grit and acid-etched (SLA) and chemically modified SLA (modSLA) titanium implants with differently structured transmucosal surfaces (SLA implants: machined [M-SLA] or SLA [SLA-SLA]; modSLA implants: mod acid-etched [modA] [modA-modSLA] or modSLA [modSLA-modSLA]) was performed bilaterally in the upper and lower jaws of 15 beagle dogs. The animals were sacrificed after 1, 4, 7, 14, or 28 days. Tissue reactions were assessed histomorphometrically and immunohistochemically using monoclonal antibodies to transglutaminase II (angiogenesis) and osteocalcin. Although the junctional epithelium commonly was separated from M-SLA and SLA-SLA implants by a gap, the epithelial cells appeared to be in close contact with modA-modSLA surfaces after 14 days of healing. Moreover, modA-modSLA and modSLA-modSLA groups showed a well-vascularized subepithelial connective tissue exhibiting collagen fibers that started to extend and attach partially perpendicular to the implant surface. The highest and statistically significant mean bone-to-implant contact areas were observed in the modA-modSLA and modSLA-modSLA groups at days 7, 14, and 28. Within the limits of this study, it may be concluded that soft and hard tissue integration was influenced mainly by surface hydrophilicity rather than by microtopography.

  17. Transcatheter closure of calcified patent ductus arteriosus in older adult patients: Immediate and 12-month follow-up results.

    Science.gov (United States)

    Gu, Xinghua; Zhang, Qiuwang; Sun, Hourong; Fei, Jianchun; Zhang, Xiquan; Kutryk, Michael J

    2017-05-01

    To present our experience in transcatheter closure of calcified patent ductus arteriosus (PDA) in older adult patients, which has rarely been reported. From 2009 to 2014, a total of 16 patients (median age 58 years) with calcified PDA underwent transcatheter closure in our center. All patients were symptomatic with major symptoms being exertional dyspnea (in 12), palpitations (in 8), and fatigue (in 5). A continuous murmur was heard in all patients. The median ductus diameter was 4 mm (range 3-7 mm). The median Qp/Qs was 1.6 (range 1.4-2.9). Transcatheter closure was performed for all patients. The size of the occluder selected was 2-3 mm greater than the narrowest portion of PDA. We experienced difficulties in advancing the multipurpose catheter through the calcified duct in about one third of patients (5/16). Considering that calcified tissue has a greater tendency to rupture, hence, to close PDA in these patients, they adopted the retrograde wire-assisted technique and modified the procedure to reduce the shear stress of sheath and avoid any sheath kinking. For the remaining 11 patients, the advancement of the multipurpose catheter through the calcified duct was smooth and the conventional antegrade approach was applied. Clinical examination, standard 12-lead electrocardiography, chest x-ray, and transthoracic echocardiography were performed before hospital discharge, at 1-, 3-, 6-, and 12-months follow-ups. All PDAs were successfully closed. There were no deaths. Three patients had a trivial residual shunt, with one also having intravascular hemolysis. Following pharmacological treatment, hemolysis signs vanished at 7 days postprocedure. The trivial residual shunt disappeared in all three patients at 3-month follow-up. No new-onset residual shunt, device embolization, device dislocation, infective endocarditis, or embolism was observed at all follow-up time points. Successful closure of calcified PDA with few complications in older adult patients was achieved

  18. Food supply confers calcifiers resistance to ocean acidification

    KAUST Repository

    Ramajo, Laura; Pé rez-Leó n, Elia; Hendriks, Iris E.; Marbà , Nú ria; Krause-Jensen, Dorte; Sejr, Mikael K.; Blicher, Martin E.; Lagos, Nelson A.; Olsen, Ylva S.; Duarte, Carlos M.

    2016-01-01

    Invasion of ocean surface waters by anthropogenic CO2 emitted to the atmosphere is expected to reduce surface seawater pH to 7.8 by the end of this century compromising marine calcifiers. A broad range of biological and mineralogical mechanisms allow marine calcifiers to cope with ocean acidification, however these mechanisms are energetically demanding which affect other biological processes (trade-offs) with important implications for the resilience of the organisms against stressful conditions. Hence, food availability may play a critical role in determining the resistance of calcifiers to OA. Here we show, based on a meta-analysis of existing experimental results assessing the role of food supply in the response of organisms to OA, that food supply consistently confers calcifiers resistance to ocean acidification.

  19. Epidural tumour (calcified fibroma) as cause of a 'Cervical Syndrome'

    International Nuclear Information System (INIS)

    Piotrowski, W.P.

    1983-01-01

    A calcified fibroma caused a so called cervical syndrome not responding to medical treatment. In the computerized tomography a compression of the cervical spinal cord could be demonstrated. From this the indication for the operation was given. (Author)

  20. Food supply confers calcifiers resistance to ocean acidification

    KAUST Repository

    Ramajo, Laura

    2016-01-18

    Invasion of ocean surface waters by anthropogenic CO2 emitted to the atmosphere is expected to reduce surface seawater pH to 7.8 by the end of this century compromising marine calcifiers. A broad range of biological and mineralogical mechanisms allow marine calcifiers to cope with ocean acidification, however these mechanisms are energetically demanding which affect other biological processes (trade-offs) with important implications for the resilience of the organisms against stressful conditions. Hence, food availability may play a critical role in determining the resistance of calcifiers to OA. Here we show, based on a meta-analysis of existing experimental results assessing the role of food supply in the response of organisms to OA, that food supply consistently confers calcifiers resistance to ocean acidification.

  1. Epidural tumour (calcified fibroma) as cause of a 'Cervical Syndrome'

    Energy Technology Data Exchange (ETDEWEB)

    Piotrowski, W P

    1983-01-01

    A calcified fibroma caused a so called Cervical Syndrome not responding to medical treatment. In the computerized tomography a compression of the cervical spinal cord could be demonstrated. From this the indication for the operation was given.

  2. CHANGES IN TOOTH HARD TISSUE MINERALI-ZATION AND BLOOD RHEOLOGY IN HEALTHY ADOLESCENTS AND THOSE WITH THYROID DYSFUNCTION.

    Science.gov (United States)

    Beriashvili, S; Nikolaishvili, M; Mantskava, M; Momtsemlidze, N; Franchuk, K

    2016-11-01

    Thyroid dysfunction causes spreading and development of caries in the teeth and changes in periodontal tissues. In addition, it causes changes in peripheral blood flow and mineralization, local transcapillary metabolism causes changes in blood rheology. There are only few works in this direction and, therefore, the purpose of our research was to find out how the mineralization and the rheological properties of blood are changed in lesion of periodontal tissue on a background of thyroid dysfunction. Accordingly, the stomatological study was conducted in 75 adolescents aged 12-18 years by the standard method, recommended by the World Health Organization. According to the study, 45 patients out of them suffered from thyroid dysfunction, in particular from hypothyroidism. The comparator group consisted of 30 children of the same age without endocrine abnormalities. By the gained results it is noted that in spite of different type lesions due to dental caries, the caries incidence and intensiveness is higher in children with hypothyroidism as compared to healthy children. Decrease in saliva excretion rate and increase in oral fluid viscosity was found in children with thyroid and endocrine diseases as compared to healthy children. In children with endocrine disorders concurrent increase in calcium content (1,43±0,08 mmol/l) and decrease in inorganic phosphate concentrations (4,54±0,15 mmol/l) is reliably established. In children with thyroid disfunction and while periodontal tissue pathology, rheological features are disordered more dramatically than in healthy children. Therefore, it can be said that the changes in the adolescents' thyroid function is one of the reasons for formation of periodontal tissue diseases.Therefore, at detecting even the first signs of the periodontal tissue diseases, it is desirable in adolescents to assess the thyroid functional condition, since it will be the precondition for effective treatment and management of dental disease, in

  3. Severe calcified stylohyoid complex in twins: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jo Eun; Min, Jung Hyun; Park, Hae Rang; Choi, Bo Ram; Huh, Kyung Hoe [School of Dentistry, Seoul National University, Seoul (Korea, Republic of); Choi, Jin Woo [Dankook University College of Dentistry, Cheonan (Korea, Republic of)

    2012-06-15

    The styloid process is a cylindrical, long cartilaginous bone located on the temporal bone. The calcified stylohyoid ligament and elongated styloid process can be identified radiographically, and they are associated with a number of syndromes and symptoms. The exact cause of the styloid process elongation due to calcification and subsequent ossification of ligament is unclear. This report presents a case of severely calcified stylohyoid ligament complex occurred in twins who have the same pattern of calcification.

  4. Development of a novel anisotropic self-inflating tissue expander: in vivo submucoperiosteal performance in the porcine hard palate.

    Science.gov (United States)

    Swan, Marc C; Bucknall, David G; Czernuszka, Jan T; Pigott, David W; Goodacre, Timothy E E

    2012-01-01

    The advent of self-inflating hydrogel tissue expanders heralded a significant advance in the reconstructive potential of this technique. Their use, however, is limited by their uncontrolled isotropic (i.e., uniform in all directions) expansion. Anisotropy (i.e., directional dependence) was achieved by annealing a hydrogel copolymer of poly(methyl methacrylate-co-vinyl pyrrolidone) under a compressive load for a specified time period. The expansion ratio is dictated by the percentage of vinyl pyrrolidone content and the degree of compression. The expansion rate is modified by incorporating the polymer within a silicone membrane. The in vivo efficacy of differing prototype devices was investigated in juvenile pigs under United Kingdom Home Office Licence. The devices were implanted within a submucoperiosteal pocket in a total of six porcine palates; all were euthanized by 6 weeks after implantation. A longitudinal volumetric assessment of the expanded tissue was conducted, in addition to postmortem analysis of the bony and mucoperiosteal palatal elements. Uncoated devices caused excessive soft-tissue expansion that resulted in mucoperiosteal ulceration, thus necessitating animal euthanasia. The silicone-coated devices produced controlled soft-tissue expansion over the 6-week study period. There was a statistically significant increase in the volume of expanded soft tissue with no evidence of a significant acute inflammatory response to the implant, although peri-implant capsule formation was observed. Attenuation of the bony palatal shelf was noted. A unique anisotropic hydrogel device capable of controlled expansion has been developed that addresses a number of the shortcomings of the technology hitherto available.

  5. Computational cell quantification in the human brain tissues based on hard x-ray phase-contrast tomograms

    Science.gov (United States)

    Hieber, Simone E.; Bikis, Christos; Khimchenko, Anna; Schulz, Georg; Deyhle, Hans; Thalmann, Peter; Chicherova, Natalia; Rack, Alexander; Zdora, Marie-Christine; Zanette, Irene; Schweighauser, Gabriel; Hench, Jürgen; Müller, Bert

    2016-10-01

    Cell visualization and counting plays a crucial role in biological and medical research including the study of neurodegenerative diseases. The neuronal cell loss is typically determined to measure the extent of the disease. Its characterization is challenging because the cell density and size already differs by more than three orders of magnitude in a healthy cerebellum. Cell visualization is commonly performed by histology and fluorescence microscopy. These techniques are limited to resolve complex microstructures in the third dimension. Phase- contrast tomography has been proven to provide sufficient contrast in the three-dimensional imaging of soft tissue down to the cell level and, therefore, offers the basis for the three-dimensional segmentation. Within this context, a human cerebellum sample was embedded in paraffin and measured in local phase-contrast mode at the beamline ID19 (ESRF, Grenoble, France) and the Diamond Manchester Imaging Branchline I13-2 (Diamond Light Source, Didcot, UK). After the application of Frangi-based filtering the data showed sufficient contrast to automatically identify the Purkinje cells and to quantify their density to 177 cells per mm3 within the volume of interest. Moreover, brain layers were segmented in a region of interest based on edge detection. Subsequently performed histological analysis validated the presence of the cells, which required a mapping from the two- dimensional histological slices to the three-dimensional tomogram. The methodology can also be applied to further tissue types and shows potential for the computational tissue analysis in health and disease.

  6. The mechanical heterogeneity of the hard callus influences local tissue strains during bone healing: a finite element study based on sheep experiments.

    Science.gov (United States)

    Vetter, A; Liu, Y; Witt, F; Manjubala, I; Sander, O; Epari, D R; Fratzl, P; Duda, G N; Weinkamer, R

    2011-02-03

    During secondary fracture healing, various tissue types including new bone are formed. The local mechanical strains play an important role in tissue proliferation and differentiation. To further our mechanobiological understanding of fracture healing, a precise assessment of local strains is mandatory. Until now, static analyses using Finite Elements (FE) have assumed homogenous material properties. With the recent quantification of both the spatial tissue patterns (Vetter et al., 2010) and the development of elastic modulus of newly formed bone during healing (Manjubala et al., 2009), it is now possible to incorporate this heterogeneity. Therefore, the aim of this study is to investigate the effect of this heterogeneity on the strain patterns at six successive healing stages. The input data of the present work stemmed from a comprehensive cross-sectional study of sheep with a tibial osteotomy (Epari et al., 2006). In our FE model, each element containing bone was described by a bulk elastic modulus, which depended on both the local area fraction and the local elastic modulus of the bone material. The obtained strains were compared with the results of hypothetical FE models assuming homogeneous material properties. The differences in the spatial distributions of the strains between the heterogeneous and homogeneous FE models were interpreted using a current mechanobiological theory (Isakson et al., 2006). This interpretation showed that considering the heterogeneity of the hard callus is most important at the intermediate stages of healing, when cartilage transforms to bone via endochondral ossification. Copyright © 2010 Elsevier Ltd. All rights reserved.

  7. High peak power Q-switched Er:YAG laser with two polarizers and its ablation performance for hard dental tissues.

    Science.gov (United States)

    Yang, Jingwei; Wang, Li; Wu, Xianyou; Cheng, Tingqing; Jiang, Haihe

    2014-06-30

    An electro-optically Q-switched high-energy Er:YAG laser with two polarizers is proposed. By using two Al(2)O(3) polarizing plates and a LiNbO(3) crystal with Brewster angle, the polarization efficiency is significantly improved. As a result, 226 mJ pulse energy with 62 ns pulse width is achieved at the repetition rate of 3 Hz, the corresponding peak power is 3.6 MW. To our knowledge, such a high peak power has not been reported in literature. With our designed laser, in-vitro teeth were irradiated under Q-switched and free-running modes. Results of a laser ablation experiment on hard dental tissue with the high-peak-power laser demonstrates that the Q-switched Er:YAG laser has higher ablation precision and less thermal damage than the free-running Er:YAG laser.

  8. Characterization of a posed smile and evaluation of facial attractiveness by panel perception and its correlation with hard and soft tissue.

    Science.gov (United States)

    Malhotra, Smriti; Sidhu, Maninder Singh; Prabhakar, Mona; Kochhar, Anuraj Singh

    2012-01-01

    To examine whether specific hard and soft tissue had any effect on smile characteristics and to ascertain the opinions of laypersons and clinicians in evaluating facial attractiveness among different occlusions. Photographs of posed smiles, along with profiles and full faces, of 76 patients with different occlusions were captured, and a lateral cephalogram of each subject was traced. These photographs were judged by a panel of 10 clinicians and 10 laypersons on a 5-point visual analog scale. Quantitative measurements were carried out on the smile images for 14 smile characteristics. The effect of hard and soft tissue on these characteristics was also examined. The upper vermilion lip thickness was affected by Pt.A-UI and E-line to upper lip, while the lower vermilion lip thickness was affected by lower anterior facial height. FMA had a significant positive effect on gingival display (P ≤ .05). This meant that an increase in FMA also caused the gingival display to increase. The nasolabial angle showed a significant positive effect on incisal display, while FMA showed a negative effect on intercanine width. Lower facial height and FMA had a significant negative effect on the smile index. A correlation was found between the judgments of clinicians and laypersons. Both judged Class I relationships to be the most attractive. FMA was found to have a positive effect on the amount of gingival display. It was also observed that patients with Class II Division 1 relationships had the thickest lips compared with patients having other types of occlusions. Class III patients exhibited no gingival display on smile. Patients with Class I showed the maximum smile width, while patients with Class III showed the least amount of buccal corridor.

  9. Calcified cartilage or bone? Collagens in the tessellated endoskeletons of cartilaginous fish (sharks and rays).

    Science.gov (United States)

    Seidel, Ronald; Blumer, Michael; Pechriggl, Elisabeth-Judith; Lyons, Kady; Hall, Brian K; Fratzl, Peter; Weaver, James C; Dean, Mason N

    2017-10-01

    The primary skeletal tissue in elasmobranchs -sharks, rays and relatives- is cartilage, forming both embryonic and adult endoskeletons. Only the skeletal surface calcifies, exhibiting mineralized tiles (tesserae) sandwiched between a cartilage core and overlying fibrous perichondrium. These two tissues are based on different collagens (Coll II and I, respectively), fueling a long-standing debate as to whether tesserae are more like calcified cartilage or bone (Coll 1-based) in their matrix composition. We demonstrate that stingray (Urobatis halleri) tesserae are bipartite, having an upper Coll I-based 'cap' that merges into a lower Coll II-based 'body' zone, although tesserae are surrounded by cartilage. We identify a 'supratesseral' unmineralized cartilage layer, between tesserae and perichondrium, distinguished from the cartilage core in containing Coll I and X (a common marker for mammalian mineralization), in addition to Coll II. Chondrocytes within tesserae appear intact and sit in lacunae filled with Coll II-based matrix, suggesting tesserae originate in cartilage, despite comprising a diversity of collagens. Intertesseral joints are also complex in their collagenous composition, being similar to supratesseral cartilage closer to the perichondrium, but containing unidentified fibrils nearer the cartilage core. Our results indicate a unique potential for tessellated cartilage in skeletal biology research, since it lacks features believed diagnostic for vertebrate cartilage mineralization (e.g. hypertrophic and apoptotic chondrocytes), while offering morphologies amenable for investigating the regulation of complex mineralized ultrastructure and tissues patterned on multiple collagens. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Hard alpha-keratin degradation inside a tissue under high flux X-ray synchrotron micro-beam: a multi-scale time-resolved study.

    Science.gov (United States)

    Leccia, Emilie; Gourrier, Aurélien; Doucet, Jean; Briki, Fatma

    2010-04-01

    X-rays interact strongly with biological organisms. Synchrotron radiation sources deliver very intense X-ray photon fluxes within micro- or submicro cross-section beams, resulting in doses larger than the MGy. The relevance of synchrotron radiation analyses of biological materials is therefore questionable since such doses, million times higher than the ones used in radiotherapy, can cause huge damages in tissues, with regard to not only DNA, but also proteic and lipid organizations. Very few data concerning the effect of very high X-ray doses in tissues are available in the literature. We present here an analysis of the structural phenomena which occur when the model tissue of human hair is irradiated by a synchrotron X-ray micro-beam. The choice of hair is supported by its hierarchical and partially ordered keratin structure which can be analysed inside the tissue by X-ray diffraction. To assess the damages caused by hard X-ray micro-beams (1 microm(2) cross-section), short exposure time scattering SAXS/WAXS patterns have been recorded at beamline ID13 (ESRF) after various irradiation times. Various modifications of the scattering patterns are observed, they provide fine insight of the radiation damages at various hierarchical levels and also unexpectedly provide information about the stability of the various hierarchical structural levels. It appears that the molecular level, i.e. the alpha helices which are stabilized by hydrogen bonds and the alpha-helical coiled coils which are stabilized by hydrophobic interactions, is more sensitive to radiation than the supramolecular architecture of the keratin filament and the filament packing within the keratin associated proteins matrix, which is stabilized by disulphide bonds. (c) 2009 Elsevier Inc. All rights reserved.

  11. Ameloblastomatous calcifying odontogenic cyst: A rare histologic variant

    Directory of Open Access Journals (Sweden)

    Basavaraj N Kallalli

    2015-01-01

    Full Text Available Ameloblastoma is a well-known odontogenic tumor that can be associated with calcifying odontogenic cysts (COCs, but only a few reports give its clinical and radiographic features. Calcifying odontogenic cyst was first categorized as a distinct entity by Gorlin et al., and has been named after him since then. Calcifying odontogenic cyst is an uncommon developmental odontogenic lesion that demonstrates histopathologic diversity. It is well known that this lesion can occur in association with odontogenic tumors such as complex odontoma and ameloblastoma. The term COC was not included by the World Health Organization (WHO in its report of 2005 and is called calcifying cystic odontogenic tumor (CCOT. Histopathologic examination of ameloblastomatous CCOT reveals ameloblastic islands containing ghost cells. Although association of ameloblastoma with this lesion is important, only a few cases have been reported in literature. The present case report is of ameloblastomatous calcifying cystic odontogenic tumor, a rare histologic variant, in a 20-year-old male patient in the left mandibular posterior region.

  12. Microscopic Observation of Self-Propagation of Calcifying Nanoparticles (Nanobacteria)

    Science.gov (United States)

    Mathew, Grace; McKay, David S.; Ciftcioglu, Neva

    2007-01-01

    Biologists typically define living organisms as carbon and water-based cellular forms with :self-replication" as the fundamental trait of the life process. However, this standard dictionary definition of life does not help scientists to categorize self-replicators like viruses, prions, proteons and artificial life. CNP also named nanobacteria were discovered in early 1990s as about 100 nanometer-sized bacteria-like particles with unique apatite mineral-shells around them, and found to be associated with pathological-calcification related diseases. Although CNP have been isolated and cultured from mammalian blood and diseased calcified tissues, and their biomineralizing properties well established, their biological nature and self-replicating capability have always been severely challenged. The terms "self-replication", "self-assembly" or "self-propagation" have been widely used for all systems including nanomachines, crystals, computer viruses and memes. In a simple taxonomy, all biological and non-biological "self replicators", have been classified into "living" or "nonliving" based on the properties of the systems and the amount of support they require to self-replicate. To enhance our understanding about self-replicating nature of CNP, we have investigated their growth in specific culture conditions using conventional inverted light microscope and BioStation IM, Nikon s latest time-lapse imaging system. Their morphological structure was examined using scanning (SEM) and transmission (TEM) electron microscopy. This present study, in conjunction with previous findings of metabolic activity, antibiotic sensitivity, antibody specificity, morphological aspects and infectivity, all concomitantly validate CNP as living self-replicators.

  13. Histological and ultrastructural effect of an Nd:YAG pulsed laser beam on dental hard tissue and pulp

    Science.gov (United States)

    Vignato, Costantino; Vignato, Giuseppe; Nardelli, Antonella; Baldan, Arianna; Mason, Pier N.

    1994-09-01

    The purpose of this study was to determine histological and ultrastructural modifications produced by an Nd:YAG pulsed laser beam after an in vivo exposure of human molars. Using a Nd:YAG pulsed laser beam delivered by a 600 micrometers optical fiber and concurrent air and water cooling spray, 14 human third molars with artificial first class cavities were exposed at different power levels (6, 7, and 8 W). All the teeth were extracted at different time periods between 10 and 25 days and prepared for histological examination. The results of the histological examination showed no evidence of degeneration or necrosis of the pulpar tissue. Analysis of the dentinal surfaces after exposure demonstrated that the dentinal tubules are completely closed due to the melted dentin. In conclusion a Nd:YAG pulsed laser beam with an air and water cooling spray is safe for treatments of class I decay and no necrosis or degeneration of the pulp was found for laser powers of 6, 7, and 8 W.

  14. Modern views on the pathogenesis of hard dental tissues and periodontium lesions and means of their treatment in children with chronic diseases of the gastrointestinal tract

    Directory of Open Access Journals (Sweden)

    Krupey V.Y.

    2014-09-01

    Full Text Available Changes in the mouth covity often reflect regularities of pathogenesis of a number of disease states, and primarily from the digestive tract. Therefore, the purpose of the study was to clarify pathogenesis of certain lesions of hard dental tissues and periodontal tissues in children with chronic diseases of the gastrointestinal tract and development of schemes for their treatment. The study observed 441 children aged from 7 to 15 years with dental caries and generalized chronic catarrhal gingivitis on the background of chronic gastritis and duodenitis, duodenal ulcer and malabsorption syndrome. All the children were divided into 2 groups - basic and comparison one. The study identified the most dan¬gerous and little-known way of pathogenesis, which passes through the general processes of reducing the production of various proteins (immune system and antiseptics, is a violation of the general and local resistance and, ultimately, mineral metabolism. Such disorders impair complete mineralization of tooth enamel, reduce optimal composition and properties of saliva stimulating glycolysis processes in oral cavity. Prevention of dental caries and generalized chronic catarrhal gingivitis in children with chronic pathology of the gastrointestinal tract is based on the use of developed therapeutic and prophylactic complex, which includes mucosal gel Kvertulin, probiotic Latsidofil and drug Calcium D.

  15. Progression from calcifying tendinitis to rotator cuff tear

    Energy Technology Data Exchange (ETDEWEB)

    Gotoh, Masafumi; Higuchi, Fujio; Suzuki, Ritsu; Yamanaka, Kensuke [Department of Orthopaedic Surgery, Medical Center of Kurume University, 155-1 Kokubu-machi, Kurume City, Fukuoka 839-0862 (Japan)

    2003-02-01

    This report documents the clinical, radiographic and histologic findings in a 46-year-old man with calcifying tendinitis in his left shoulder which progressed to rotator cuff tear. The patient had a 1-year history of repeated calcifying tendinitis before being referred to our hospital. On the initial visit, radiographs and magnetic resonance imaging (MRI) revealed calcium deposition localized in the supraspinatus tendon without apparent tear. Three months after the first visit, MRI revealed a partial-thickness rotator cuff tear at the site of calcium deposition. Surgical and histologic findings demonstrated that calcium deposition was the cause of cuff rupture. To our knowledge, based on a review of the English literature, this is the first case report in which the progression from calcifying tendinitis to rotator cuff tear has been serially observed. (orig.)

  16. Progression from calcifying tendinitis to rotator cuff tear

    International Nuclear Information System (INIS)

    Gotoh, Masafumi; Higuchi, Fujio; Suzuki, Ritsu; Yamanaka, Kensuke

    2003-01-01

    This report documents the clinical, radiographic and histologic findings in a 46-year-old man with calcifying tendinitis in his left shoulder which progressed to rotator cuff tear. The patient had a 1-year history of repeated calcifying tendinitis before being referred to our hospital. On the initial visit, radiographs and magnetic resonance imaging (MRI) revealed calcium deposition localized in the supraspinatus tendon without apparent tear. Three months after the first visit, MRI revealed a partial-thickness rotator cuff tear at the site of calcium deposition. Surgical and histologic findings demonstrated that calcium deposition was the cause of cuff rupture. To our knowledge, based on a review of the English literature, this is the first case report in which the progression from calcifying tendinitis to rotator cuff tear has been serially observed. (orig.)

  17. Calcifying Odontogenic Cyst Associated with an Impacted Upper Cuspid

    International Nuclear Information System (INIS)

    Yoon, Suk Ja; Lee, Young Seo; Yi, Jae Seo

    2000-01-01

    A 35-year-old man was referred to the department of Oral and maxillofacial surgery of Chonnam university hospital for the chief complaint of asymptomatic swelling on the buccal vestibule of upper right canine area. Radiographs revealed that the upper right canine was impacted and there was a well-circumscribed pericoronal radiolucency related with the canine. Multiple radiopaque foci were scattered in the radiolucent lesion, and the roots of the lateral incisor and the first premolar related to the lesion showed external resorption. The radiographic features of this lesion were typical of adenomatoid odontogenic tumor, but considering the sex and age of the patient, the tentative diagnosis was made as calcifying odontogenic cyst. Microscopically this lesion was diagnosed as calcifying odontogenic cyst. Because calcifying odontogenic cyst has no pathognomonic feature of radiographs, to consider radiographic features with clinical findings is necessary in order to establish more correct diagnosis.

  18. The effect of subcrestal placement of the polished surface of ITI implants on marginal soft and hard tissues.

    Science.gov (United States)

    Hämmerle, C H; Brägger, U; Bürgin, W; Lang, N P

    1996-06-01

    In order to achieve esthetically more satisfying results, it has been proposed to place ITI implants with their border between the rough and smooth surfaces below the level of the alveolar crest, thereby obtaining a submucosally located implant shoulder following healing. The aim of the present experimental study was to clinically and radiographically evaluate the tissue response to the placement of one-stage transmucosal implants with the border between the rough and the smooth surfaces sunk by 1 mm into a subcrestal location. 11 patients underwent comprehensive dental care including the placement of 2 implants of the ITI Dental Implant System in the same quadrant (test and control). Randomly assigned control implants were placed according to the manufacturer's instructions, i.e. the border between the rough titanium plasma-sprayed and the smooth polished surfaces precisely at the alveolar crest. At the test implant the apical border of the polished surface was placed approximately 1 mm below the alveolar crest. Probing bone levels were assessed at implant placement (baseline), 4 and 12 months later. Modified plaque and modified gingival indices were recorded at 1, 2, 3, 4 and 12 months. Clinical probing depth and "attachment" levels were measured at 4 and 12 months. All parameters were assessed at 6 sites around each implant. The mean for each implant was calculated and used for analysis. The Wilcoxon matched pairs signed rank test and the Student t-test were applied to detect differences over time and between the test and control implants. At baseline, a mean difference in probing bone level of -0.86 mm (SD 0.43 mm, p placed more deeply. Both test and control implants lost a significant amount of clinical bone height during the first 4 months (test 1.16 mm, p placed under standard conditions, the bone adjacent to the polished surface of more deeply placed ITI implants is also lost over time. From a biological point of view, the placement of the border between

  19. A Comparison in Mechanical Properties of Cermets of Calcium Silicate with Ti-55Ni and Ti-6Al-4V Alloys for Hard Tissues Replacement

    Science.gov (United States)

    Pramanik, Sumit; Shirazi, Seyed Farid Seyed; Mehrali, Mehdi; Yau, Yat-Huang; Abu Osman, Noor Azuan

    2014-01-01

    This study investigated the impact of calcium silicate (CS) content on composition, compressive mechanical properties, and hardness of CS cermets with Ti-55Ni and Ti-6Al-4V alloys sintered at 1200°C. The powder metallurgy route was exploited to prepare the cermets. New phases of materials of Ni16Ti6Si7, CaTiO3, and Ni31Si12 appeared in cermet of Ti-55Ni with CS and in cermet of Ti-6Al-4V with CS, the new phases Ti5Si3, Ti2O, and CaTiO3, which were emerged during sintering at different CS content (wt%). The minimum shrinkage and density were observed in both groups of cermets for the 50 and 100 wt% CS content, respectively. The cermets with 40 wt% of CS had minimum compressive Young's modulus. The minimum of compressive strength and strain percentage at maximum load were revealed in cermets with 50 and 40 wt% of CS with Ti-55Ni and Ti-6Al-4V cermets, respectively. The cermets with 80 and 90 wt% of CS showed more plasticity than the pure CS. It concluded that the composition and mechanical properties of sintered cermets of Ti-55Ni and Ti-6Al-4V with CS significantly depend on the CS content in raw cermet materials. Thus, the different mechanical properties of the cermets can be used as potential materials for different hard tissues replacements. PMID:25538954

  20. A Comparison in Mechanical Properties of Cermets of Calcium Silicate with Ti-55Ni and Ti-6Al-4V Alloys for Hard Tissues Replacement

    Directory of Open Access Journals (Sweden)

    Azim Ataollahi Oshkour

    2014-01-01

    Full Text Available This study investigated the impact of calcium silicate (CS content on composition, compressive mechanical properties, and hardness of CS cermets with Ti-55Ni and Ti-6Al-4V alloys sintered at 1200°C. The powder metallurgy route was exploited to prepare the cermets. New phases of materials of Ni16Ti6Si7, CaTiO3, and Ni31Si12 appeared in cermet of Ti-55Ni with CS and in cermet of Ti-6Al-4V with CS, the new phases Ti5Si3, Ti2O, and CaTiO3, which were emerged during sintering at different CS content (wt%. The minimum shrinkage and density were observed in both groups of cermets for the 50 and 100 wt% CS content, respectively. The cermets with 40 wt% of CS had minimum compressive Young’s modulus. The minimum of compressive strength and strain percentage at maximum load were revealed in cermets with 50 and 40 wt% of CS with Ti-55Ni and Ti-6Al-4V cermets, respectively. The cermets with 80 and 90 wt% of CS showed more plasticity than the pure CS. It concluded that the composition and mechanical properties of sintered cermets of Ti-55Ni and Ti-6Al-4V with CS significantly depend on the CS content in raw cermet materials. Thus, the different mechanical properties of the cermets can be used as potential materials for different hard tissues replacements.

  1. Scientific analysis of a calcified object from a post-medieval burial in Vienna, Austria.

    Science.gov (United States)

    Binder, Michaela; Berner, Margit; Krause, Heike; Kucera, Matthias; Patzak, Beatrix

    2016-09-01

    Calcifications commonly occur in association with soft tissue inflammation. However, they are not often discussed in palaeopathological literature, frequently due to problems of identification and diagnosis. We present a calcified object (40×27×27cm) found with a middle-aged male from a post-medieval cemetery in Vienna. It was not recognized during excavation, thus its anatomical location within the body remains unknown. The object was subject to X-ray, SEM and CT scanning and compared to historic pathological objects held in the collection of the Natural History Museum Vienna. Two of closest resemblance, a thyroid adenoma and goitre were subject to similar analytical techniques for comparison. Despite similarities between all objects, the structure of the object most closely conforms to a thyroid tumor. Nevertheless, due to similar pathophysiological pathways and biochemical composition of calcified soft tissue, a secure identification outside of its anatomical context is not possible. The research further highlights the fact that recognition of such objects during excavation is crucial for a more conclusive diagnosis. Historic medical records indicate that they were common and might therefore be expected to frequently occur in cemeteries. Consequently, an increasing the dataset of calcifications would also aid in extending the knowledge about diseases in past human populations. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. A calcified epidermoid cyst within right lateral ventricle: A report of a rare case

    Directory of Open Access Journals (Sweden)

    Ranjan Kumar Sahoo

    2016-01-01

    Full Text Available A young patient reported to neurosurgery outdoor department with symptoms of increased intracranial pressure. Noncontrast computed tomography examination showed a single calcified mass within right lateral ventricle with mild hydrocephalus. Contrast-enhanced magnetic resonance imaging revealed nonenhancing single mass within right lateral ventricle with mild hydrocephalus. Intraventricular calcified choroid papilloma/calcified epidermoid were radiological differentials. The mass was excised, removed from the lateral ventricles and found to be calcified epidermoid on gross and microscopic examination, which is rare.

  3. Calcifying/ossifying synovial sarcoma: A clinicopathologic and molecular study of 5 cases

    Directory of Open Access Journals (Sweden)

    Nasir Ud Din

    2015-01-01

    Full Text Available Background: Synovial sarcoma (SS is a soft tissue sarcoma with a generally aggressive behavior. Calcifying/ossifying SS is a rare variant associated with a favorable prognosis. Aim: The aim was to report clinicopathological features and molecular analysis of 5 cases of calcifying/ossifying SS. Materials and Methods: Record of 370 cases of SS reported in the section of Histopathology, of a tertiary care Hospital, between 2002 and 2011 were retrieved. Five cases exhibiting extensive calcification and ossification were identified. Immunohistochemistry was performed using Flex technique. Molecular analysis of these 5 cases was performed later at the collaborative Hospital abroad, by reverse transcription polymerase chain reaction. Results and Conclusions: The ages of the patients ranged from 13 to 44 years (mean age 27 years; female to male ratio 1.6:1. The duration of symptoms ranged from 5 months to 5 years. Histologically, 4 were monophasic, and 1 was biphasic. Three cases exhibited extensive calcification and two extensive ossification. Immunohistochemical stain (epithelial membrane antigen was positive in all 5 cases, CKAE1/AE3 (3/4, Bcl2 (4/4, S100 (4/4, CK7 (2/2, CD99 (1/3 and vimentin (2/2. Intact RNA was obtained from 3 cases, all of which were positive for the SYT/SSX fusion transcript. Follow-up was available in 4 cases and ranged from 19 months to 85 months (mean 50 months. Local recurrence was seen in 2 cases. In conclusions, we report clinicopathologic features of 5 cases of calcifying/ossifying SS. The duration of symptoms and mean age of patients is similar to the literature. A slight female predominance was seen in contrast to a male predominance described in the literature. The clinical course of our cases validates the favorable prognosis of this rare type of SS.

  4. A calcified epidermoid cyst within right lateral ventricle: A report of a rare case

    OpenAIRE

    Ranjan Kumar Sahoo; Debahuti Mohapatra; Pradipta Tripathy

    2016-01-01

    A young patient reported to neurosurgery outdoor department with symptoms of increased intracranial pressure. Noncontrast computed tomography examination showed a single calcified mass within right lateral ventricle with mild hydrocephalus. Contrast-enhanced magnetic resonance imaging revealed nonenhancing single mass within right lateral ventricle with mild hydrocephalus. Intraventricular calcified choroid papilloma/calcified epidermoid were radiological differentials. The mass was excised, ...

  5. Case report: Calcified chronic subdural haematoma in an elderly ...

    African Journals Online (AJOL)

    Calcified chronic subdural haematoma [CCSDH] is a rare complication of the relatively more common condition of Chronic Subdural Haematoma (CSDH). We present the case of a 68yr old man referred with a 2 week history of sudden onset Right hemi paresis generalized tonic clonic seizures and aphasia. There was a ...

  6. A case of multiple cardiac calcified amorphous tumours

    Directory of Open Access Journals (Sweden)

    Amrit Chowdhary

    2017-05-01

    Full Text Available Cardiac calcified amorphous tumours of the heart are rare non-neoplastic cardiac masses that can present like a malignant mass or an intra-cardiac thrombus. We report an extremely unusual case of a 73 year old man who presented to hospital with dyspnoea and subsequent investigations revealed multiple cardiac CATs.

  7. Are calcifying matrix vesicles in atherosclerotic lesions of cellular origin?

    Science.gov (United States)

    Bobryshev, Yuri V; Killingsworth, Murray C; Huynh, Thuan G; Lord, Reginald S A; Grabs, Anthony J; Valenzuela, Stella M

    2007-03-01

    Over recent years, the role of matrix vesicles in the initial stages of arterial calcification has been recognized. Matrix calcifying vesicles have been isolated from atherosclerotic arteries and the biochemical composition of calcified vesicles has been studied. No studies have yet been carried out to examine the fine structure of matrix vesicles in order to visualize the features of the consequent stages of their calcification in arteries. In the present work, a high resolution ultrastructural analysis has been employed and the study revealed that matrix vesicles in human atherosclerotic lesions are heterogeneous with two main types which we classified. Type I calcified vesicles were presented by vesicles surrounded by two electron-dense layers and these vesicles were found to be resistant to the calcification process in atherosclerotic lesions in situ. Type II matrix vesicles were presented by vesicles surrounded by several electron-dense layers and these vesicles were found to represent calcifying vesicles in atherosclerotic lesions. To test the hypothesis that calcification of matrix vesicles surrounded by multilayer sheets may occur simply as a physicochemical process, independently from the cell regulation, we produced multilamellar liposomes and induced their calcification in vitro in a manner similar to that occurring in matrix vesicles in atherosclerotic lesions in situ.

  8. Atherectomy for calcified coronary lesions: When and how?

    Science.gov (United States)

    Karatasakis, Aris; Brilakis, Emmanouil S

    2016-03-01

    Percutaneous coronary intervention of heavily calcified lesions can be challenging. Although the ROTAXUS trial did not demonstrate long-term clinical benefit with routine rotational atherectomy, atherectomy remains an indispensable tool to achieve acute procedural success. Until new data becomes available determining when and how to optimally use coronary atherectomy depends heavily on personal experience and clinical judgment. © 2016 Wiley Periodicals, Inc.

  9. Calcifying supracoracoid bursitis as a cause of chronic shoulder pain.

    Science.gov (United States)

    Mens, J; van der Korst, J K

    1984-01-01

    A case of chronic shoulder pain is reported with marked limitation of both active and passive elevations and a normal range of motion of the glenohumeral joint. X-ray examination demonstrated cloudy calcification in the coracoclavicular region, presumably indicating calcifying supracoracoid bursitis. Images PMID:6497468

  10. An exceptional collision tumor: gastric calcified stromal tumor and ...

    African Journals Online (AJOL)

    The authors report an exceptional case of collision tumor comprised of a gastric calcified stromal tumor and a pancreatic adenocarcinoma. The pancreatic tumor was detected fortuitously on the histological exam of resection specimen. Key words: Collision tumor, stromal tumor, adenocarcinoma ...

  11. Microscopic study of dental hard tissues in primary teeth with Dentinogenesis Imperfecta Type II: Correlation of 3D imaging using X-ray microtomography and polarising microscopy.

    Science.gov (United States)

    Davis, Graham R; Fearne, Janice M; Sabel, Nina; Norén, Jörgen G

    2015-07-01

    The aim of this study was to examine the histological appearance of dental hard tissues in primary teeth from children with DI using conventional polarised light microscopy and correlate that with 3D imaging using X-ray microtomograpy (XMT) to gain a further understanding of the dentine structure of teeth diagnosed with dentinogenesis imperfecta. Undecalcified sections of primary teeth from patients diagnosed with Dentinogenesis Imperfecta Type II were examined using polarised light microscopy. XMT was employed for 3D-imaging and analysis of the dentine. The polarised light microscopy and XMT revealed tubular structures in the dentine seen as vacuoles coinciding with the path of normal dentinal tubules but not continuous tubules. The size of the tubules was close to that of capillaries. The largest tubular structures had a direction corresponding to where the pulp tissue would have been located during primary dentine formation. The dysfunctional mineralisation of the dentine and obliteration of the pulp evidently leaves blood vessels in the dentine which have in the main been tied off and, in the undecalcified sections, appear as vacuoles. Although from radiographs, the pulp in teeth affected by Dentinogenesis Imperfect type II appears to be completely obliterated, a network of interconnected vessels may remain. The presence of large dentinal tubules and blood vessels, or the remnants of blood vessels, could provide a pathway for bacteria from the oral cavity. This might account for why some of these teeth develop periapical abscesses in spite of apparently having no pulp. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Collagen hydrogels incorporated with surface-aminated mesoporous nanobioactive glass: Improvement of physicochemical stability and mechanical properties is effective for hard tissue engineering.

    Science.gov (United States)

    El-Fiqi, Ahmed; Lee, Jae Ho; Lee, Eun-Jung; Kim, Hae-Won

    2013-12-01

    Collagen (Col) hydrogels have poor physicochemical and mechanical properties and are susceptible to substantial shrinkage during cell culture, which limits their potential applications in hard tissue engineering. Here, we developed novel nanocomposite hydrogels made of collagen and mesoporous bioactive glass nanoparticles (mBGns) with surface amination, and addressed the effects of mBGn addition (Col:mBG = 2:1, 1:1 and 1:2) and its surface amination on the physicochemical and mechanical properties of the hydrogels. The amination of mBGn was shown to enable chemical bonding with collagen molecules. As a result, the nanocomposite hydrogels exhibited a significantly improved physicochemical and mechanical stability. The hydrolytic and enzymatic degradation of the Col-mBGn hydrogels were slowed down due to the incorporation of mBGn and its surface amination. The mechanical properties of the hydrogels, specifically the resistance to loading as well as the stiffness, significantly increased with the addition of mBGn and its aminated form, as assessed by a dynamic mechanical analysis. Mesenchymal stem cells cultivated within the Col-mBGn hydrogels were highly viable, with enhanced cytoskeletal extensions, due to the addition of surface aminated mBGn. While the Col hydrogel showed extensive shrinkage (down to ∼20% of initial size) during a few days of culture, the shrinkage of the mBGn-added hydrogel was substantially reduced, and the aminated mBGn-added hydrogel had no observable shrinkage over 21 days. Results demonstrated the effective roles of aminated mBGn in significantly improving the physicochemical and mechanical properties of Col hydrogel, which are ultimately favorable for applications in stem cell culture for bone tissue engineering. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  13. Comparative evaluation of soft and hard tissue dimensions in the anterior maxilla using radiovisiography and cone beam computed tomography: A pilot study

    Directory of Open Access Journals (Sweden)

    Savita Mallikarjun

    2016-01-01

    Full Text Available Aims: To assess and compare the thickness of gingiva in the anterior maxilla using radiovisiography (RVG and cone beam computed tomography (CBCT and its correlation with the thickness of underlying alveolar bone. Settings and Design: This cross-sectional study included 10 male subjects in the age group of 20–45 years. Materials and Methods: After analyzing the width of keratinized gingiva of the maxillary right central incisor, the radiographic assessment was done using a modified technique for RVG and CBCT, to measure the thickness of both the labial gingiva and labial plate of alveolar bone at 4 predetermined locations along the length of the root in each case. Statistical Analysis Used: Statistical analysis was performed using Student's t-test and Pearson's correlation test, with the help of statistical software (SPSS V13. Results: No statistically significant differences were obtained in the measurement made using RVG and CBCT. The results of the present study also failed to reveal any significant correlation between the width of gingiva and the alveolar bone in the maxillary anterior region. Conclusions: Within the limitations of this study, it can be concluded that both CBCT and RVG can be used as valuable tools in the assessment of the soft and hard tissue dimensions.

  14. Degradation and in vitro cell–material interaction studies on hydroxyapatite-coated biodegradable porous iron for hard tissue scaffolds

    Directory of Open Access Journals (Sweden)

    Nurizzati Mohd Daud

    2014-10-01

    Full Text Available This paper describes degradation and cell–material interaction studies on hydroxyapatite (HA-coated biodegradable porous iron proposed for hard tissue scaffolds. Porous iron scaffolds are expected to serve as an ideal platform for bone regeneration. To couple their inherent mechanical strength, pure HA and HA/poly(ε-caprolactone (HA/PCL were coated onto porous iron using dip coating technique. The HA/PCL mixture was prepared to provide a more stable and flexible coating than HA alone. Degradation of the samples was evaluated by weight loss and potentiodynamic polarisation. Human skin fibroblast (HSF and human mesenchymal stem cells (hMSC were put in contact with the samples and their interaction was observed. Results showed that coated samples degraded ∼10 times slower (0.002 mm/year for HA/PCL-Fe, 0.003 mm/year for HA-Fe than the uncoated ones (0.031 mm/year, indicating an inhibition effect of the coating on degradation. Both HSF and hMSC maintained high viability when in contact with the coated samples (100–110% control for hMSC during 2–5 days of incubation, indicating the effect of HA in enhancing cytocompatibility of the surface. This study provided early evidence of the potential translation of biodegradable porous iron scaffolds for clinical use in orthopedic surgery. However, further studies including in vitro and in vivo tests are necessary.

  15. Non-calcifying and Langerhans cell-rich variant of calcifying epithelial odontogenic tumor

    Directory of Open Access Journals (Sweden)

    Hung-Pin Lin

    2016-06-01

    Full Text Available This study reported the clinicopathological features, treatment and prognosis of nine cases of noncalcifying and Langerhans cell (LC-rich calcifying epithelial odontogenic tumor (CEOT collected from the English literature. Of the nine cases, seven were intraosseous and two were extraosseous. All nine tumors were found in Asian patients. The age of the nine patients ranged from 20 years to 58 years with a mean age of 41 years. There were five female and four male patients. The seven intraosseous cases included six in the anterior and premolar region of the maxilla and one in the posterior region and ascending ramus of the mandible. The two extraosseous cases were located at the upper lateral incisor and premolar gingivae, respectively. Of the seven intraosseous cases, five showed unilocular and two multilocular radiolucency without foci of calcification. Six of the seven intraosseous cases showed resorption of the tooth roots in the tumor-involved region. Histologically, noncalcifying and LC-rich CEOTs were composed of small nests and thin strands of tumor epithelial cells with a relatively high number of LCs among them. This was the reason why we classed these nine cases as noncalcifying and LC-rich CEOTs. Two extraosseous cases received total excision of the gingival mass. For the seven intraosseous cases, four accepted partial maxillectomy or mandibulectomy, two received total excision or enucleation, and one underwent curettage. The six cases with the follow-up information available showed no tumor recurrence after a follow-up period of 6 months to 10 years.

  16. Novel resorbable glass-ceramic scaffolds for hard tissue engineering: from the parent phosphate glass to its bone-like macroporous derivatives.

    Science.gov (United States)

    Bretcanu, Oana; Baino, Francesco; Verné, Enrica; Vitale-Brovarone, Chiara

    2014-05-01

    One of the major challenges of hard tissue engineering research focuses on the development of scaffolds that can match the mechanical properties of the host bone and resorb at the same rate as the bone is repaired. The aim of this work was the synthesis and characterization of a resorbable phosphate glass, as well as its application for the fabrication of three dimensional (3-D) scaffolds for bone regeneration. The glass microstructure and behaviour upon heating were analysed by X-ray diffraction, differential scanning calorimetry and hot stage microscopy. The glass solubility was investigated according to relevant ISO standards using distilled water, simulated body fluid (SBF) and Tris-HCl as testing media. The glass underwent progressive dissolution over time in all three media but the formation of a hydroxyapatite-like layer was also observed on the samples soaked in SBF and Tris-HCl, which demonstrated the bioactivity of the material. The glass powder was used to fabricate 3-D macroporous bone-like glass-ceramic scaffolds by adopting polyethylene particles as pore formers: during thermal treatment, the polymer additive was removed and the sintering of glass particles was allowed. The obtained scaffolds exhibited high porosity (87 vol.%) and compressive strength around 1.5 MPa. After soaking for 4 months in SBF, the scaffolds mass loss was 76 wt.% and the pH of the solution did not exceed the 7.55 value, thereby remaining in a physiological range. The produced scaffolds, being resorbable, bioactive, architecturally similar to trabecular bone and exhibiting interesting mechanical properties, can be proposed as promising candidates for bone repair applications.

  17. Scientific Instrument for a Controlled Choice of Optimal Photon Energy Spectrum: A Comparison Between Calculational Methods and Laboratory Irradiations of Comparable Hard Tissue Phantoms

    International Nuclear Information System (INIS)

    Helmrot, E.; Sandborg, M.; Eckerdal, O.; Alm Carlsson, G.

    1998-01-01

    Basic performance parameters are defined and analysed in order to optimise physical image quality in relation to the energy imparted to the patient in dental radiology. Air cavities were embedded in well-defined multi material, hard tissue phantoms to represent various objects in dento-maxillo-facial examinations. Basic performance parameters were: object contrast (C), energy imparted (ε) to the patient, signal-to-noise ration (SNR), C 2 /ε (film) and (SNR) / ε (digital imaging system) as functions of HVL (half-value layer), used to describe the photon energy spectrum. For the film receptor, the performance index C 2 /ε is maximum (optimal) at HVL values of 1.5-1.7 mm Al in the simulated Incisive, Premolar and Molar examinations. Other imaging tasks (examinations), not simulated here, may require other optimal HVL. For the digital imaging system (Digora) the performance index (SNR) 2 /ε, theoretically calculated, indicates that a lower value of HVL is optimal than with film as receptor. However, due to the limited number of bits (8 bits) in the analogue to digital converter (ADC) contrast resolution is degraded and calls for use of higher photon energies (HVL). Customised optimisations with proper concern for patient category, type of examination, diagnostic task is the ultimate goal of this work. The conclusions stated above give some general advice on the appropriate choice of photon energy spectrum (HVL). In particular situations, it may be necessary to use more dose demanding kV settings (lower HVL) in order to get sufficient image quality for the diagnostic task. (author)

  18. Framework for detection and localization of coronary non-calcified plaques in cardiac CTA using mean radial profiles.

    Science.gov (United States)

    Jawaid, Muhammad Moazzam; Riaz, Atif; Rajani, Ronak; Reyes-Aldasoro, Constantino Carlos; Slabaugh, Greg

    2017-10-01

    The high mortality rate associated with coronary heart disease (CHD) has driven intensive research in cardiac imaging and image analysis. The advent of computed tomography angiography (CTA) has turned non-invasive diagnosis of cardiovascular anomalies into reality as calcified coronary plaques can be easily identified due to their high intensity values. However, the detection of non-calcified plaques in CTA is still a challenging problem because of lower intensity values, which are often similar to the nearby blood and muscle tissues. In this work, we propose the use of mean radial profiles for the detection of non-calcified plaques in CTA imagery. Accordingly, we computed radial profiles by averaging the image intensity in concentric rings around the vessel centreline in a first stage. In the subsequent stage, an SVM classifier is applied to identify the abnormal coronary segments. For occluded segments, we further propose a derivative-based method to localize the position and length of the plaque inside the segment. A total of 32 CTA volumes were analysed and a detection accuracy of 88.4% with respect to the manual expert was achieved. The plaque localization accuracy was computed using the Dice similarity coefficient and a mean of 83.2% was achieved. The consistent performance for multi-vendor, multi-institution data demonstrates the reproducibility of our method across different CTA datasets with a good agreement with manual expert annotations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Tomographic appearance of calcified intervertebral discs in miniature Dachshund; Aparência tomográfica dos discos intervertebrais mineralizados em cães da raça Dachshund Miniatura

    Energy Technology Data Exchange (ETDEWEB)

    Baraúna Júnior, D.; Fernandes, T.H.T.; Silva, I.C.C.; Bonelli, M.A.; Santos, C.R.O.; Amorim, M.M.A., E-mail: durvalbarauna@hotmail.com [Universidade Federal do Vale do São Francisco (UNIVASF), Petrolina, PE (Brazil); Costa, F.S.; Tudury, E.A. [Universidade Federal Rural de Pernambuco (UFRPE), Recife, PE (Brazil)

    2017-07-01

    The objective was to describe CT imaging of calcified IVD in one-year-old Dachshunds, as well as describe the location in the soft tissue structures that make up the IVD. Ten one-year-old dogs underwent computed tomography (CT). In sagittal reconstruction images of animals, the identification of 70 IVD present in the spaces between L3 - T9 were performed. Among calcified IVDs, the presence of the change was determined as the location in the nucleus pulposus (NP), annulus fibrous (AF) and both. Of a total of 70 evaluated IVDs, 45 were found to calcified and 25 not calcified. Among calcified discs, location was determined in nine (20%) in NP, eight discs (17.77%) in AF and 28 (62, 23%) NP and AF. Calcification in this study was characterized by increased radiographic attenuation mineral density in the IVD topography. There is variation in the location and radio density of calcified areas between animals and IVD in the same individual. Changes related to IVD calcification can be classified as tomographic location in AF, NP and NP and AF. (author)

  20. Calcified tumours of the paranasal sinuses in three horses.

    Science.gov (United States)

    Schaaf, K L; Kannegieter, N J; Lovell, D K

    2007-11-01

    Three horses, a 10-year-old Thoroughbred mare, a 9-year-old Thoroughbred gelding and a 6-year-old Arab gelding, with calcified tumours of the paranasal sinuses, are described. All horses presented with purulent nasal discharges and facial distortion. Exophthalmos, blepharospasm and ocular discharge were also a feature in individual horses. A presumptive diagnosis of a calcified tumour was made on the basis of clinical signs and radiographic and endoscopic findings. The tumours ranged from 15 to 25 cm in diameter. A large frontonasal bone flap was used to expose the tumours, which were cleaved into several pieces with an osteotome and removed. Histological examination of the masses identified cementomas in two cases and an osteoma in the third. Long term follow up from 18 months to 5 years after surgery indicated that there was no recurrence. This case series demonstrates that, although calcified tumours of the paranasal sinuses are rare in horses, they should be considered in the differential diagnosis of purulent nasal discharge, facial swelling and ocular distortion, and are amenable to surgical treatment.

  1. ARTHROSCOPIC TREATMENT OF CALCIFYING TENDINITIS OF THE ROTATOR CUFF.

    Science.gov (United States)

    Neto, Arnaldo Amado Ferreira; Trevizani, Cassio Silva; Benegas, Eduardo; Malavolta, Eduardo Angeli; Gracitelli, Mauro Emílio Conforto; Bitar, Alexandre Carneiro; Neto, Francisco José Dos Santos

    2010-01-01

    To evaluate the clinical and radiographic results from arthroscopic surgical treatment of the rotator cuff in patients with calcifying tendinitis. A retrospective study was conducted on twenty patients who underwent arthroscopic treatment for calcifying tendinitis of the shoulder between March 1999 and November 2005. Six patients were excluded due to loss of follow-up. The average follow-up period was 41.4 months. Eight patients (57%) were female and six (43%) were male. The right side was affected in 10 cases (71%) and the left in four cases (29%). Nine cases (64%) had calcification in the supraspinatus tendon, two (14%) in the infraspinatus tendon, and three (21%) in both tendons. In all cases, resection of the calcium deposits was performed by means of a needle (Jelco® No. 14) in combination with curettage (mini-curette). Two shoulders (14%) underwent subacromial decompression, and one (7%) underwent excision of the distal clavicle. A tendon-tendon suture was performed in three shoulders (21%). None of the patients underwent tendon-bone reinsertion. The mean score obtained on the UCLA scale was 33 points (26-35), thus indicating that a majority of patients had good results. In the final radiographic evaluation, none of the patients showed signs of calcification. Arthroscopic treatment of calcifying tendinitis of the shoulder safely allows excision of the calcification, leading to good results in relation to shoulder pain and function.

  2. Tissue

    Directory of Open Access Journals (Sweden)

    David Morrissey

    2012-01-01

    Full Text Available Purpose. In vivo gene therapy directed at tissues of mesenchymal origin could potentially augment healing. We aimed to assess the duration and magnitude of transene expression in vivo in mice and ex vivo in human tissues. Methods. Using bioluminescence imaging, plasmid and adenoviral vector-based transgene expression in murine quadriceps in vivo was examined. Temporal control was assessed using a doxycycline-inducible system. An ex vivo model was developed and optimised using murine tissue, and applied in ex vivo human tissue. Results. In vivo plasmid-based transgene expression did not silence in murine muscle, unlike in liver. Although maximum luciferase expression was higher in muscle with adenoviral delivery compared with plasmid, expression reduced over time. The inducible promoter cassette successfully regulated gene expression with maximum levels a factor of 11 greater than baseline. Expression was re-induced to a similar level on a temporal basis. Luciferase expression was readily detected ex vivo in human muscle and tendon. Conclusions. Plasmid constructs resulted in long-term in vivo gene expression in skeletal muscle, in a controllable fashion utilising an inducible promoter in combination with oral agents. Successful plasmid gene transfection in human ex vivo mesenchymal tissue was demonstrated for the first time.

  3. Calcifying tendinitis of the rotator cuff with focal umeral osteolysis. Imaging features

    OpenAIRE

    V. V. Mascarenhas; F. Morais; H. Marques; A. Guerra; E. Carpinteiro; A. Gaspar

    2015-01-01

    Calcifying tendinitis occurs most commonly in the rotator cuff tendons, particularly involving the supraspinatus tendon insertion, and is often asymptomatic. Cortical erosion secondary to calcifying tendinitis has been reported in multiple locations, including in the rotator cuff tendons. The authors report two cases of symptomatic calcifying tendinitis involving the infraspinatus tendon with cortical erosion with correlative radiographic, and MR findings. The importance of considering this d...

  4. [Calcifying tendinitis of the rotator cuff with focal umeral osteolysis. Imaging features].

    Science.gov (United States)

    Mascarenhas, V V; Morais, F; Marques, H; Guerra, A; Carpinteiro, E; Gaspar, A

    2015-01-01

    Calcifying tendinitis occurs most commonly in the rotator cuff tendons, particularly involving the supraspinatus tendon insertion, and is often asymptomatic. Cortical erosion secondary to calcifying tendinitis has been reported in multiple locations, including in the rotator cuff tendons. The authors report two cases of symptomatic calcifying tendinitis involving the infraspinatus tendon with cortical erosion with correlative radiographic, and MR findings. The importance of considering this diagnosis when evaluating lytic lesions of the humerus and the imaging differential diagnosis of calcifying tendinitis and cortical erosion are discussed.

  5. Calcifying tendinitis of the rotator cuff with focal umeral osteolysis. Imaging features

    Directory of Open Access Journals (Sweden)

    V. V. Mascarenhas

    2015-10-01

    Full Text Available Calcifying tendinitis occurs most commonly in the rotator cuff tendons, particularly involving the supraspinatus tendon insertion, and is often asymptomatic. Cortical erosion secondary to calcifying tendinitis has been reported in multiple locations, including in the rotator cuff tendons. The authors report two cases of symptomatic calcifying tendinitis involving the infraspinatus tendon with cortical erosion with correlative radiographic, and MR findings. The importance of considering this diagnosis when evaluating lytic lesions of the humerus and the imaging differential diagnosis of calcifying tendinitis and cortical erosion are discussed.

  6. Calcifying Odontogenic Cyst with Complex Odontoma: Histological and Immunohistochemical Features

    Directory of Open Access Journals (Sweden)

    Nooshin Mohtasham

    2013-01-01

    Full Text Available The calcifying odontogenic cyst (COC is a rare odontogenic cyst. Only 2% of all odontogenic cysts and tumors are COC. COC associated with odontoma (COCaO reported in 24% of COCs. COCaO presents a greater incidence in female, with a ratio of 2 to 1. The highest incidence of COCaO occurs during the second decade with a mean age of 16 years, most frequently occurring in the maxilla (61.5%. Here, we describe a classic case of COCaO of the maxillary incisor-canine region in 17-year-old girl, and discuss the clinicopathological features and immunohistochemical finding of this tumor.

  7. Calcifying Odontogenic Cyst with Complex Odontoma: Histological and Immunohistochemical Features

    Directory of Open Access Journals (Sweden)

    Mohsen Merati

    2012-09-01

    Full Text Available The calcifying odontogenic cyst (COC is a rare odontogenic cyst. Only 2% of all odontogenic cysts and tumors are COC. COC associated with odontoma (COCaO reported in 24% of COCs. COCaO presents a greater incidence in female, with a ratio of 2 to 1. The highest incidence of COCaO occurs during the second decade with a mean age of 16 years, most frequently occurring in the maxilla (61.5%. Here, we describe a classic case of COCaO of the maxillary incisor-canine region in 17-year-old girl, and discuss the clinicopathological features and immunohistochemical finding of this tumor.

  8. Coral calcifying fluid aragonite saturation states derived from Raman spectroscopy

    Directory of Open Access Journals (Sweden)

    T. M. DeCarlo

    2017-11-01

    Full Text Available Quantifying the saturation state of aragonite (ΩAr within the calcifying fluid of corals is critical for understanding their biomineralization process and sensitivity to environmental changes including ocean acidification. Recent advances in microscopy, microprobes, and isotope geochemistry enable the determination of calcifying fluid pH and [CO32−], but direct quantification of ΩAr (where ΩAr =  [CO32−][Ca2+]∕Ksp has proved elusive. Here we test a new technique for deriving ΩAr based on Raman spectroscopy. First, we analysed abiogenic aragonite crystals precipitated under a range of ΩAr from 10 to 34, and we found a strong dependence of Raman peak width on ΩAr with no significant effects of other factors including pH, Mg∕Ca partitioning, and temperature. Validation of our Raman technique for corals is difficult because there are presently no direct measurements of calcifying fluid ΩAr available for comparison. However, Raman analysis of the international coral standard JCp-1 produced ΩAr of 12.3 ± 0.3, which we demonstrate is consistent with published skeletal Mg∕Ca, Sr∕Ca, B∕Ca, δ11B, and δ44Ca data. Raman measurements are rapid ( ≤  1 s, high-resolution ( ≤  1 µm, precise (derived ΩAr ± 1 to 2 per spectrum depending on instrument configuration, accurate ( ±2 if ΩAr < 20, and require minimal sample preparation, making the technique well suited for testing the sensitivity of coral calcifying fluid ΩAr to ocean acidification and warming using samples from natural and laboratory settings. To demonstrate this, we also show a high-resolution time series of ΩAr over multiple years of growth in a Porites skeleton from the Great Barrier Reef, and we evaluate the response of ΩAr in juvenile Acropora cultured under elevated CO2 and temperature.

  9. A rare fatality due to calcified stylohyoid ligament (Eagle syndrome).

    Science.gov (United States)

    Gupta, Avneesh; Aggrawal, Anil; Setia, Puneet

    2017-06-01

    The elongation or calcification of the stylohyoid ligament that leads to pressure symptoms, or entrapment of nearby glossopharyngeal nerve or carotid artery, is known as Eagle syndrome. A PubMed search leads to finding of rare fatality among the 49 reported cases. In the present case, the deceased was a 40-year-old male who choked on his food. We hypothesise that the impaction of food in the upper respiratory tract, as well as the inability to intubate the person, were both the result of the calcified stylohyoid ligament.

  10. Endovascular Sharp Recanalization for Calcified Femoropopliteal Artery Occlusion

    Directory of Open Access Journals (Sweden)

    Hsuan-Li Huang

    2012-01-01

    Full Text Available Endovascular intervention of peripheral chronic total occlusion (CTO is technically challenging and time consuming. Various techniques and devices are used to facilitate lesion crossing and improve the success rate of the procedure. However, these new devices are quite expensive and not readily available. We report 2 cases of peripheral CTO wherein the occlusions were successfully crossed by using stiff end of Terumo glidewire. This sharp recanalization may be a useful technique for the recanalization of calcified peripheral CTOs when conventional techniques fail and new devices are not readily available, but it is accompanied by the risk of distal atheroembolism.

  11. The problem of calcified ascending aorta during aortocoronary bypass

    Directory of Open Access Journals (Sweden)

    Nežić Duško G.

    2004-01-01

    Full Text Available Heavily calcified ascending aorta significantly increased morbidity and lethality during open-heart surgery. Cannulation and clamping (partial or total of severely atherosclerotic ascending aorta can easily cause damage and rupture of aortic wall, with consequential distal (often fatal embolization with atheromatous debris (brain, myocardium. From June 1998. until June 2000, 11 of 2 136 (0.5% patients who underwent coronary artery bypass grafting were with the severe atheromatous ascending aorta. The site of cannulation was in the aortic arch in three patients (aorta was occluded with Foley catheter in one case, and single clamp technique was used in the other two cases. The femoral artery was the cannulation site in other five cases. Profound hypothermia, ventricular fibrillation, and circulatory arrest, with no cross-clamping or cardioplegia, were used in three patients. Two patients were operated on with extracorporeal circulation, one in normothermia, on the beating heart, the other in moderate hypothermia, on fibrillating heart. In three patients myocardial revascularization was performed on the beating heart, in normothermia, without extracorporeal circulation. Postoperative course was uneventful in all 11 patients. Neither atheroembolism in the peripheral organs, nor atheroembolism of the extramities occurred. The proposed surgical approaches have the potential to reduce the prevalence of stroke and systemic embolization associated with coronary artery bypass grafting in patients with heavily calcified ascending aorta. This result was achieved due to the applied modifications of standard cardiosurgical technique.

  12. Treatment of Necrotic Calcified Tooth Using Intentional Replantation Procedure

    Directory of Open Access Journals (Sweden)

    Nima Moradi Majd

    2014-01-01

    Full Text Available Introduction. If the teeth are impacted by a chronic irritant, the pulp space possibly will undergo calcific changes that may impede access opening during root canal treatment. In such cases that conventional endodontic treatment is impossible or impractical, intentional replantation may be considered as a last solution to preserve the tooth. Methods. After failing to perform conventional root canal therapy for a necrotic calcified right mandibular second premolar, the tooth was gently extracted. The root apex was resected and the root end cavity was prepared and filled with calcium enriched mixture (CEM cement. Then, the extracted tooth was replanted in its original position. Results. After a year the tooth was asymptomatic, and the size of periapical radiolucency was remarkably reduced and no clinical sign of ankylosis was observed. Conclusion. Intentional replantation of the necrotic calcified teeth could be considered as an alternative to teeth extraction, especially for the single-rooted teeth and when nonsurgical and surgical endodontic procedures seem impossible.

  13. Calcifying mucinous adenocarcinoma of the stomach: Report of two cases

    International Nuclear Information System (INIS)

    Sung, Ki Yeal; Han, Seong Tai; Bahk, Yong Whee

    1983-01-01

    There is a great variety of abdominal calcifications of varying etiology. Among them, calcification in gastric carcinoma is rare. To the best of our knowledge, there has been no previous report of calcifying mucinous adenocarcinoma of the stomach in Korea. In the present communication, we report toe cases of this rare tumor. The first cases was 27 years old female who had anorexia and palpable mass in the epigastrium. By palpation, a firm non-tender large mass was felt in the epigastrium. A plain abdominal film showed numerous punctuate calcifications in the left upper quadrant. Film from an upper G-I series demonstrated findings of advanced gastric carcinoma with multiple punctuate calcifications involving the antrum and body. Gastroscopic biopsy proved the lesion to be mucinous adenocarcinoma (signet ring cell type). The second case was 38 years old female who complicated of nausea, vomiting and weight loss. On physical examination, she appeared normal. Routine laboratory tests were within normal limits. A plain abdominal film reveal stippled calcifications in the left upper quadrant medial to the splenic shadow. The film from an upper G-I series showed a mass in the fundus and upper body of stomach with multiple stippled calcifications along the lesser curvature. Subtotal gastrectomy was performed and the pathologic finding was calcifying mucinous adenocarcinoma (signet ring cell type)

  14. The effects of healing abutments of different size and anatomic shape placed immediately in extraction sockets on peri-implant hard and soft tissues. A pilot study in foxhound dogs.

    Science.gov (United States)

    López-López, Patricia J; Mareque-Bueno, Javier; Boquete-Castro, Ana; Aguilar-Salvatierra Raya, Antonio; Martínez-González, José M; Calvo-Guirado, José L

    2016-01-01

    The aim of this animal study was to compare the effects of narrow, concave-straight and wide anatomic healing abutments on changes to soft tissues and crestal bone levels around implants immediately placed into extraction sockets in foxhound dogs. Forty-eight titanium implants (Bredent Medical GMBH, Germany) of the same dimensions were placed in six foxhound dogs. They were divided into two groups (n = 24): test (implants with anatomic abutment) and control (implants with concave-straight abutment). The implants were inserted randomly in the post extraction sockets of P2 , P3 , P4, and M1 bilaterally in six dogs. After eight and twelve weeks, the animals were sacrificed and samples extracted containing the implants and the surrounding soft and hard tissues. Soft tissue and crestal bone loss (CBL) were evaluated by histology and histomorphometry. All implants were clinically and histologically osseointegrated. Healing patterns were examined microscopically at eight and twelve weeks. After eight and twelve weeks, for hard tissues, the distance from the implant shoulder to the first bone-to-implant contact (IS-C) was higher for control group in the lingual aspect with statistical significance (P < 0.05). For soft tissues (STL), the distance from the top of the peri-implant mucosa to the apical portion of the junction epithelium (PM-Je) was significantly less on the lingual aspect in the test group (with wider abutment) at eight and twelve weeks (P < 0.05). The distance from the top of the apical portion of the junction epithelium to the first bone-to-implant contact (Je-C) was significantly higher in the test group (wider abutment) in the lingual aspect at eight and twelve weeks (P < 0.05). There was no connective tissue contact with any abutment surface. Within the limitations of this animal study, anatomic healing abutments protect soft and hard tissues and reduce crestal bone resorption compared with concave-straight healing abutments. © 2014 John Wiley

  15. The significance of calcified fibrocartilage on the cortical endplate of the translational sheep spine model.

    Science.gov (United States)

    Sinclair, Sarina K; Bell, Spencer; Epperson, Richard Tyler; Bloebaum, Roy D

    2013-05-01

    To gain an understanding of the vertebral cortical endplate and factors that may affect the ability to achieve skeletal attachment to intervertebral implants and fusion, this study aimed to characterize the hypermineralized tissue on the cortical endplate of the vertebral body on a commonly used animal model. Skeletally mature sheep were injected with tetracycline prior to euthanasia and the C2-C3, T5-T6, and L2-L3 spinal motion segments were excised and prepared. Vertebral tissues were imaged using backscatter electron (BSE) imaging, histology, and tetracycline labeling was used to assess bone remodeling within different tissue layers. It was determined that the hypermineralized tissue layer was calcified fibrocartilage (CFC). No tetracycline labels were identified in the CFC layer, in contrast to single and double labels that were present in the underlying bone, indicating the CFC present on the cortical endplate was not being actively remodeled. The average thickness of the CFC layer was 146.3 ± 70.53 µm in the cervical region, 98.2 ± 40.29 µm in the thoracic region, and 150.89 ± 69.25 µm in the lumbar region. This difference in thickness may be attributed to the regional biomechanical properties of the spine. Results from this investigation indicate the presence of a nonremodeling tissue on the cortical endplate of the vertebral body in sheep spines, which attaches the intervertebral disc to the vertebrae. This tissue, if not removed, would likely prevent successful bony attachment to an intervertebral device in spinal fusion studies and total disc replacement surgeries. Copyright © 2013 Wiley Periodicals, Inc.

  16. Association Between Osteogenesis and Inflammation During the Progression of Calcified Plaque Evaluated by 18F-Fluoride and 18F-FDG.

    Science.gov (United States)

    Li, Xiang; Heber, Daniel; Cal-Gonzalez, Jacobo; Karanikas, Georgios; Mayerhoefer, Marius E; Rasul, Sazan; Beitzke, Dietrich; Zhang, Xiaoli; Agis, Hermine; Mitterhauser, Markus; Wadsak, Wolfgang; Beyer, Thomas; Loewe, Christian; Hacker, Marcus

    2017-06-01

    18 F-FDG is the most widely validated PET tracer for the evaluation of atherosclerotic inflammation. Recently, 18 F-NaF has also been considered a potential novel biomarker of osteogenesis in atherosclerosis. We aimed to analyze the association between inflammation and osteogenesis at different stages of atherosclerosis, as well as the interrelationship between these 2 processes during disease progression. Methods: Thirty-four myeloma patients underwent 18 F-NaF and 18 F-FDG PET/CT examinations. Lesions were divided into 3 groups (noncalcified, mildly calcified, and severely calcified lesions) on the basis of calcium density as measured in Hounsfield units by CT. Tissue-to-background ratios were determined from PET for both tracers. The association between inflammation and osteogenesis during atherosclerosis progression was evaluated in 19 patients who had at least 2 examinations with both tracers. Results: There were significant correlations between the maximum tissue-to-background ratios of the 2 tracers (Spearman r = 0.5 [ P < 0.01]; Pearson r = 0.4 [ P < 0.01]) in the 221 lesions at baseline. The highest uptake of both tracers was observed in noncalcified lesions, but without any correlation between the tracers (Pearson r = 0.06; P = 0.76). Compared with noncalcified plaques, mildly calcified plaques showed concordant significantly lower accumulation, with good correlation between the tracers (Pearson r = 0.7; P < 0.01). In addition, enhanced osteogenesis-derived 18 F-NaF uptake and regressive inflammation-derived 18 F-FDG uptake were observed in severely calcified lesions (Pearson r = 0.4; P < 0.01). During follow-up, increased calcium density and increased mean 18 F-NaF uptake were observed, whereas mean 18 F-FDG uptake decreased. Most noncalcified (86%) and mildly calcified (81%) lesions and 47% of severely calcified lesions had concordant development of both vascular inflammation and osteogenesis. Conclusion: The combination of 18 F-NaF PET imaging and 18 F

  17. The role of calcified cartilage and subchondral bone in the initiation and progression of ochronotic arthropathy in alkaptonuria.

    Science.gov (United States)

    Taylor, A M; Boyde, A; Wilson, P J M; Jarvis, J C; Davidson, J S; Hunt, J A; Ranganath, L R; Gallagher, J A

    2011-12-01

    Alkaptonuria is a genetic disorder of tyrosine metabolism, resulting in elevated circulating concentrations of homogentisic acid. Homogentisic acid is deposited as a polymer, termed ochronotic pigment, in collagenous tissues, especially cartilages of weight-bearing joints, leading to a severe osteoarthropathy. We undertook this study to investigate the initiation and progression of ochronosis from the earliest detection of pigment through complete joint failure. Nine joint samples with varying severities of ochronosis were obtained from alkaptonuria patients undergoing surgery and compared to joint samples obtained from osteoarthritis (OA) patients. Samples were analyzed by light and fluorescence microscopy, 3-dimensional scanning electron microscopy (SEM), and the quantitative backscattered electron mode of SEM. Cartilage samples were mechanically tested by compression to determine Young's modulus of pigmented, nonpigmented, and OA cartilage samples. In alkaptonuria samples with the least advanced ochronosis, pigment was observed intracellularly and in the territorial matrix of individual chondrocytes at the boundary of the subchondral bone and calcified cartilage. In more advanced ochronosis, pigmentation was widespread throughout the hyaline cartilage in either granular composition or as blanket pigmentation in which there is complete and homogenous pigmentation of cartilage matrix. Once hyaline cartilage was extensively pigmented, there was aggressive osteoclastic resorption of the subchondral plate. Pigmented cartilage became impacted on less highly mineralized trabeculae and embedded in the marrow space. Pigmented cartilage samples were much stiffer than nonpigmented or OA cartilage as revealed by a significant difference in Young's modulus. Using alkaptonuria cartilage specimens with a wide spectrum of pigmentation, we have characterized the progression of ochronosis. Intact cartilage appears to be resistant to pigmentation but becomes susceptible following

  18. Standard hardness conversion tables for metals relationship among brinell hardness, vickers hardness, rockwell hardness, superficial hardness, knoop hardness, and scleroscope hardness

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 Conversion Table 1 presents data in the Rockwell C hardness range on the relationship among Brinell hardness, Vickers hardness, Rockwell hardness, Rockwell superficial hardness, Knoop hardness, and Scleroscope hardness of non-austenitic steels including carbon, alloy, and tool steels in the as-forged, annealed, normalized, and quenched and tempered conditions provided that they are homogeneous. 1.2 Conversion Table 2 presents data in the Rockwell B hardness range on the relationship among Brinell hardness, Vickers hardness, Rockwell hardness, Rockwell superficial hardness, Knoop hardness, and Scleroscope hardness of non-austenitic steels including carbon, alloy, and tool steels in the as-forged, annealed, normalized, and quenched and tempered conditions provided that they are homogeneous. 1.3 Conversion Table 3 presents data on the relationship among Brinell hardness, Vickers hardness, Rockwell hardness, Rockwell superficial hardness, and Knoop hardness of nickel and high-nickel alloys (nickel content o...

  19. Hard coatings

    International Nuclear Information System (INIS)

    Dan, J.P.; Boving, H.J.; Hintermann, H.E.

    1993-01-01

    Hard, wear resistant and low friction coatings are presently produced on a world-wide basis, by different processes such as electrochemical or electroless methods, spray technologies, thermochemical, CVD and PVD. Some of the most advanced processes, especially those dedicated to thin film depositions, basically belong to CVD or PVD technologies, and will be looked at in more detail. The hard coatings mainly consist of oxides, nitrides, carbides, borides or carbon. Over the years, many processes have been developed which are variations and/or combinations of the basic CVD and PVD methods. The main difference between these two families of deposition techniques is that the CVD is an elevated temperature process (≥ 700 C), while the PVD on the contrary, is rather a low temperature process (≤ 500 C); this of course influences the choice of substrates and properties of the coating/substrate systems. Fundamental aspects of the vapor phase deposition techniques and some of their influences on coating properties will be discussed, as well as the very important interactions between deposit and substrate: diffusions, internal stress, etc. Advantages and limitations of CVD and PVD respectively will briefly be reviewed and examples of applications of the layers will be given. Parallel to the development and permanent updating of surface modification technologies, an effort was made to create novel characterisation methods. A close look will be given to the coating adherence control by means of the scratch test, at the coating hardness measurement by means of nanoindentation, at the coating wear resistance by means of a pin-on-disc tribometer, and at the surface quality evaluation by Atomic Force Microscopy (AFM). Finally, main important trends will be highlighted. (orig.)

  20. Calcified pleural scars and pleural empyema with mural calcification

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, W.G.H.; Huebener, K.H.

    1981-06-01

    The differential diagnosis between calcified pleural scars and pleural empyemas with mural calcification was studied by computer tomography, bearing in mind the patient's history. In view of the high complication rate of pleural empyemas, such as internal or external fistulae, it is desirable to elucidate every form of pleural shadowing which is more than 20 mm thick. Criteria are offered, which permit the differentiation of the pleural changes by means of conventional radiological examinations. Valuable additional information can be obtained by computer tomography. Forty-nine patients with calcification in the pleura were found among 1.900 chest x-rays which had been examined. Out of these, seven had a pleural empyema. In one case an echinococcus cyst with mural calcification was punctured under X-ray control.

  1. Calcified pleural scars and pleural empyema with mural calcification

    International Nuclear Information System (INIS)

    Schmitt, W.G.H.; Huebener, K.H.

    1981-01-01

    The differential diagnosis between calcified pleural scars and pleural empyemas with mural calcification was studied by computer tomography, bearing in mind the patient's history. In view of the high complication rate of pleural empyemas, such as internal or external fistulae, it is desirable to elucidate every form of pleural shadowing which is more than 20 mm thick. Criteria are offered, which permit the differentiation of the pleural changes by means of conventional radiological examinations. Valuable additional information can be obtained by computer tomography. Forty-nine patients with calcification in the pleura were found among 1.900 chest x-rays which had been examined. Out of these, seven had a pleural empyema. In one case an echinococcus cyst with mural calcification was punctured under X-ray control. (orig.) [de

  2. Calcifying epithelial odontogenic tumor of the posterior maxilla

    Directory of Open Access Journals (Sweden)

    Vidya Ajila

    2016-01-01

    Full Text Available Calcifying epithelial odontogenic tumor (CEOT is a rare odontogenic neoplasm comprising <1% of all odontogenic tumors. It is commonly seen in the third to fifth decades of life without any gender predilection. It usually occurs in the mandibular posterior region. A painless, slow growing swelling with bone expansion is the most common clinical feature of CEOT. Radiographically, it presents as a mixed lesion with or without an associated impacted tooth. Confirmation of the diagnosis is by histopathological examination. We describe an unusual case of CEOT occurring in the maxillary posterior region and involving the maxillary sinus. The associated impacted third molar was displaced to the lateral wall of the nose and root resorption was seen in all the teeth associated with the lesion. There was no evidence of calcification in conventional as well as computed tomography images.

  3. Calcified neurocysticercosis lesions and hippocampal sclerosis: potential dual pathology?

    Science.gov (United States)

    Rathore, Chaturbhuj; Thomas, Bejoy; Kesavadas, Chandrasekharan; Radhakrishnan, Kurupath

    2012-04-01

    In areas where cysticercosis is endemic, calcified neurocysticercosis lesion(s) (CNL) and hippocampal sclerosis (HS) commonly coexist in patients with localization-related epilepsies. To understand the pathogenesis of HS associated with CNL, we compared the characteristics of three groups of patients with antiepileptic drug-resistant epilepsies: CNL with HS, CNL without HS (CNL alone), and HS without CNL (HS alone). In comparison to patients with CNL alone, those with CNL with HS had CNL more frequently located in the ipsilateral temporal lobe. Those with CNL with HS had a lower incidence of febrile seizures, older age at initial precipitating injury and at onset of habitual complex partial seizures, and more frequent clustering of seizures and extratemporal/bitemporal interictal epileptiform discharges as compared to patients with HS alone. Our study illustrates that HS associated with CNL might have a different pathophysiologic basis as compared to classical HS. Wiley Periodicals, Inc. © 2012 International League Against Epilepsy.

  4. Does Laser Surgery Interfere with Optical Nerve Identification in Maxillofacial Hard and Soft Tissue?—An Experimental Ex Vivo Study

    Directory of Open Access Journals (Sweden)

    Bastian Bergauer

    2015-10-01

    Full Text Available The protection of sensitive structures (e.g., nerves from iatrogenic damage is of major importance when performing laser surgical procedures. Especially in the head and neck area both function and esthetics can be affected to a great extent. Despite its many benefits, the surgical utilization of a laser is therefore still limited to superficial tissue ablation. A remote feedback system which guides the laser in a tissue-specific way would provide a remedy. In this context, it has been shown that nerval structures can be specifically recognized by their optical diffuse reflectance spectra both before and after laser ablation. However, for a translation of these findings to the actual laser ablation process, a nerve protection within the laser pulse is of utmost significance. Thus, it was the aim of the study to evaluate, if the process of Er:YAG laser surgery—which comes with spray water cooling, angulation of the probe (60° and optical process emissions—interferes with optical tissue differentiation. For the first time, no stable conditions but the ongoing process of laser tissue ablation was examined. Therefore, six different tissue types (nerve, skin, muscle, fat, cortical and cancellous bone were acquired from 15 pig heads. Measurements were performed during Er:YAG laser ablation. Diffuse reflectance spectra (4500, wavelength range: 350–650 nm where acquired. Principal component analysis (PCA and quadratic discriminant analysis (QDA were calculated for classification purposes. The clinical highly relevant differentiation between nerve and bone was performed correctly with an AUC of 95.3% (cortial bone respectively 92.4% (cancellous bone. The identification of nerve tissue against the biological very similar fat tissue yielded good results with an AUC value of 83.4% (sensitivity: 72.3%, specificity: of 82.3%. This clearly demonstrates that nerve identification by diffuse reflectance spectroscopy works reliably in the ongoing process of

  5. Cephalometric analysis of hard and soft tissues in a 12-year-old syndromic child: A case report and update on dentofacial features of Crouzon syndrome

    Directory of Open Access Journals (Sweden)

    K Nagaraju

    2011-01-01

    Full Text Available Crouzon syndrome or craniofacial dysostosis is a rare syndrome characterized by craniosynostosis, midfacial hypoplasia and exophthalmia. The abnormalities found in this syndrome change too much from case to case depending on the suture fusion order. We report a case of a 12 year old child and a mother showing variations in the dentofacial tissues clinically and radiographically. Subsequently, the application of digital software [Dolphin Imaging 11] enabled us to solve out the case as Crouzon syndrome by analyzing the skeletal and soft tissue alterations. An update of the effects of this syndrome on various systems and dentofacial features with emphasis on tooth abnormalities is documented.

  6. Multiple-level porous polymer monoliths with interconnected cellular topology prepared by combining hard sphere and emulsion templating for use in bone tissue engineering

    Czech Academy of Sciences Publication Activity Database

    Paljevac, M.; Gradišnik, L.; Lipovšek, S.; Maver, U.; Kotek, Jiří; Krajnc, P.

    2018-01-01

    Roč. 18, č. 2 (2018), s. 1-8, č. článku 1700306. ISSN 1616-5187 R&D Projects: GA MŠk(CZ) LO1507 Institutional support: RVO:61389013 Keywords : bone tissue engineering * hierarchical materials * polymer scaffolds Subject RIV: CD - Macromolecular Chemistry OBOR OECD: Polymer science Impact factor: 3.238, year: 2016

  7. Sudden Unilateral Vision Loss Arising from Calcified Amorphous Tumor of the Left Ventricle

    Science.gov (United States)

    Nazli, Yunus; Colak, Necmettin; Atar, Inci Asli; Alpay, Mehmet Fatih; Haltas, Hacer; Eryonucu, Beyhan; Cakir, Omer

    2013-01-01

    Calcified amorphous tumor of the heart is a very rare non-neoplastic intracavitary mass. The clinical presentation is similar to that of other cardiac masses. The precise cause and best approach to treatment remain unclear. We describe a case of cardiac calcified amorphous tumor presenting with refractory unilateral vision loss that was successfully treated by surgical excision. To our knowledge, this is only the 2nd reported case of retinal arterial embolism due to cardiac calcified amorphous tumor in the English-language literature. PMID:24082378

  8. Augmentation of the hard palate thin masticatory mucosa in the potential connective tissue donor sites using two collagen materials-Clinical and histological comparison.

    Science.gov (United States)

    Bednarz, Wojciech; Kobierzycki, Christopher; Dzięgiel, Piotr; Botzenhart, Ute; Gedrange, Tomasz; Ziętek, Marek

    2016-11-01

    Due to the similarity of keratinized gingival and palatal mucosa the latter can pose as a potential donor site for gingival recession coverage. However, its availability is restricted and a thin transplant bears the risk of being rejected. The aim of the present study was to compare the clinical and histological results of thin palatal mucosa augmentation, using lyophilized Biokol ® xenogenous collagen sponge and a suspension of xenogenous Gel 0 ® pure collagen with non-augmented tissue from the same patients. Ten patients simultaneously underwent bilateral augmentation procedures using Biokol ® and Gel 0 ® collagen material. The donor sites were augmented 8 weeks prior to the harvesting of the connective tissue graft (CTG) for the gingival recession coverage procedures. Prior to the implantation of the collagen material and during the course of harvesting the augmented CTG, tissue specimens were taken for histological examination. Prior to the commencement of the study and after it, the parameters of palatal gingival thickness at 4mm (PGT1), and at 8mm apical to the gingival margin (PGT2) around the teeth neighboring the operating fields were determined. In both groups the palatal mucosa had thickened significantly in both measuring sites. An intergroup comparison revealed greater thickening of the masticatory mucosa in the Biokol ® group at both measuring points. The histological image of the grafts, obtained from sites augmented using both test methods, revealed a typical pattern of mature fibrous connective tissue. No epithelial cells were found. Augmentation of thin masticatory mucosa using Biokol ® or Gel 0 ® collagen materials resulted in a significant thickening of the mucosa, which could be demonstrated to be greater in the first group. Copyright © 2016 Elsevier GmbH. All rights reserved.

  9. Notch signaling and ghost cell fate in the calcifying cystig odontogenic tumor

    Directory of Open Access Journals (Sweden)

    Siar CH

    2011-11-01

    Full Text Available Abstract Notch signaling is an evolutionarily conserved mechanism that enables adjacent cells to adopt different fates. Ghost cells (GCs are anucleate cells with homogeneous pale eosinophilic cytoplasm and very pale to clear central areas (previous nucleus sites. Although GCs are present in a variety of odontogenic lesions notably the calcifying cystic odontogenic tumor (GCOT, their nature and process of formation remains elusive. The aim of this study was to investigate the role of Notch signaling in the cell fate specification of GCs in CCOT. Immunohistochemical staining for four Notch receptors (Notch1, Notch2, Notch3 and Notch4 and three ligands (Jagged1, Jagged2 and Delta1 was performed on archival tissues of five CCOT cases. Level of positivity was quantified as negative (0, mild (+, moderate (2+ and strong (3+. Results revealed that GCs demonstrated overexpression for Notch1 and Jagged1 suggesting that Notch1Jagged1 signaling might serve as the main transduction mechanism in cell fate decision for GCs in CCOT. Protein localizations were largely membranous and/or cytoplasmic. Mineralized GCs also stained positive implicating that the calcification process might be associated with upregulation of these molecules. The other Notch receptors and ligands were weak to absent in GCs and tumoral epithelium. Stromal endothelium and fibroblasts were stained variably positive.

  10. Coexisting Sclerosing Angiomatoid Nodular Transformation of the Spleen with Multiple Calcifying Fibrous Pseudotumors in a Patient

    Directory of Open Access Journals (Sweden)

    Jen-Chieh Lee

    2007-01-01

    Full Text Available Primary tumor or tumor-like lesions of the spleen are rare. Among them, vascular lesions are the most common. Vascular tumor of the spleen is different from the usual hemangioma of soft tissue because the vascular structure of the spleen is unique. Sclerosing angiomatoid nodular transformation (SANT is a recently described vascular lesion of the spleen. Grossly, it is a multinodular, well-circumscribed tumor containing a hypervascular core. Microscopically, it comprises three types of vessels, and each type recapitulates the immunohistochemical characteristics of the normal vascular elements of the splenic red pulp, i.e. capillaries, sinusoids, and small veins, respectively. Because of the rarity of this entity, its actual pathogenesis is still unknown. In this study, we report a case of SANT occurring in a 43-year-old woman, in whom there were also multiple calcifying fibrous pseudotumors (CFPTs in the abdominal cavity. Both SANT and CFPT are thought to be variants of inflammatory pseudotumor. Coexistence of these two rare entities in a patient has never been reported, and this fact suggests that there might be a common mechanism contributing to the formation of these two types of lesions. [J Formos Med Assoc 2007;106(3:234-239

  11. "Unusual brain stone": heavily calcified primary neoplasm with some features suggestive of angiocentric glioma.

    Science.gov (United States)

    Sajjad, Jahangir; Kaliaperumal, Chandrasekaran; Bermingham, Niamh; Marks, Charles; Keohane, Catherine

    2015-11-01

    This 40-year-old man presented with a 5-month history of progressive right-sided headache associated with visual blurring. He also had a history of epilepsy but had been seizure free with medication for the past 10 years. An initial CT scan of his brain performed 16 years previously had revealed a small area of calcification in the right parietal region. In the current presentation, he had a left-sided homonymous hemianopia but no other neurological deficits. A CT scan of his brain showed a much larger calcified, partly cystic lesion in the right parietal region. Because he was symptomatic, the lesion was excised and the cyst was drained. Histological examination of the excised tissue showed an unusual primary tumor that was difficult to classify but had some features of angiocentric glioma. The heavy calcification, mixed-density cell population, and regions with features of angiocentric glioma were most unusual. The patient remained asymptomatic 5 years after surgery, and follow-up scans did not show recurrence.

  12. How Should We Perform Rotational Atherectomy to an Angulated Calcified Lesion?

    Science.gov (United States)

    Sakakura, Kenichi; Taniguchi, Yousuke; Matsumoto, Mitsunari; Wada, Hiroshi; Momomura, Shin-Ichi; Fujita, Hideo

    2016-05-25

    Rotational atherectomy to an angulated calcified lesion is always challenging. The risk of catastrophic complications such as a burr becoming stuck or vessel perforation is greater when the calcified lesion is angulated. We describe the case of an 83-year-old female suffering from unstable angina. Diagnostic coronary angiography revealed an angulated calcified lesion in the proximal segment of the right coronary artery. We performed rotational atherectomy to the lesion, but intentionally did not advance the rotational atherectomy burr beyond the top of the angulation. We controlled the rotational atherectomy burr and stopped it just before the top of the angulation to avoid complications. Following rotational atherectomy, balloon dilatation with a non-compliant balloon was performed, and drug-eluting stents were successfully deployed. In this manuscript, we provide a review of the literature on this topic, and discuss how rotational atherectomy to an angulated calcified lesion should be performed.

  13. Small calcified lesions suggestive of neurocysticercosis are associated with mesial temporal sclerosis

    Directory of Open Access Journals (Sweden)

    Marcos C. B. Oliveira

    2014-07-01

    Full Text Available Recent studies have suggested a possible relationship between temporal lobe epilepsy with mesial temporal sclerosis (MTS and neurocysticercosis (NC. We performed a case-control study to evaluate the association of NC and MTS. Method: We randomly selected patients with different epilepsy types, including: MTS, primary generalized epilepsy (PGE and focal symptomatic epilepsy (FSE. Patients underwent a structured interview, followed by head computed tomography (CT. A neuroradiologist evaluated the scan for presence of calcified lesions suggestive of NC. CT results were matched with patients’ data. Results: More patients in the MTS group displayed calcified lesions suggestive of NC than patients in the other groups (p=0.002. On multivariate analysis, MTS was found to be an independent predictor of one or more calcified NC lesions (p=0.033. Conclusion: After controlling for confounding factors, we found an independent association between NC calcified lesions and MTS.

  14. Giant, Completely Calcified Lumbar Juxtafacet Cyst: Report of an Unusual Case

    Science.gov (United States)

    Huang, Kevin T.; Owens, Timothy R.; Wang, Teresa S.; Moreno, Jessica R.; Bagley, Jacob H.; Bagley, Carlos A.

    2013-01-01

    Study Design Case report. Objective To report the case of one patient who developed a giant, completely calcified, juxtafacet cyst. Methods A 57-year-old woman presented with a 2-year history of progressively worsening lower back pain, left leg pain, weakness, and paresthesias. Imaging showed a giant, completely calcified mass arising from the left L5–S1 facet joint, with coexisting grade I L5 on S1 anterolisthesis. The patient was treated with laminectomy, excision of the mass, and L5–S1 fixation and fusion. Results The patient had an uncomplicated postoperative course and had complete resolution of her symptoms as of 1-year follow-up. Conclusions When presented with a solid-appearing, calcified mass arising from the facet joint, a completely calcified juxtafacet cyst should be considered as part of the differential diagnosis. PMID:25083359

  15. The efficacy of extracorporeal shock wave lithotripsy on single dense calcified gallstones according to computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Takao (Mie Univ., Tsu (Japan). School of Medicine); Shimono, Kazuko; Moriyama, Shigeru; Masuda, Touru; Ikeda, Tetsuya; Umegae, Satoru; Nagata, Norikazu

    1993-05-01

    The efficacy and complications of extracorporeal shock wave lithotripsy (ESWL) for single gallstones were compared between 15 patients with a CT-lucent stone and 18 patients with a dense calcified stone. In all of five patients with a stone smaller than 10 mm in diameter, complete or sufficient clearance was observed, regardless of calcification. However, in 28 patients with a stone larger than 11 mm in diameter, the rates of complete or sufficient clearance were lower in those with a dense calcified stone (64%) than in those with a computed tomography (CT) lucent stone (93%). There was no difference in the rate of complications between patients with a CT-lucent stone and those with a dense calcified stone. These results thus suggest that extracorporeal shock wave lithotripsy may be safely employed for patients with a single calcified gallstone. (author).

  16. Sol gel-derived hydroxyapatite films over porous calcium polyphosphate substrates for improved tissue engineering of osteochondral-like constructs.

    Science.gov (United States)

    Lee, Whitaik David; Gawri, Rahul; Pilliar, Robert M; Stanford, William L; Kandel, Rita A

    2017-10-15

    Integration of in vitro-formed cartilage on a suitable substrate to form tissue-engineered implants for osteochondral defect repair is a considerable challenge. In healthy cartilage, a zone of calcified cartilage (ZCC) acts as an intermediary for mechanical force transfer from soft to hard tissue, as well as an effective interlocking structure to better resist interfacial shear forces. We have developed biphasic constructs that consist of scaffold-free cartilage tissue grown in vitro on, and interdigitated with, porous calcium polyphosphate (CPP) substrates. However, as CPP degrades, it releases inorganic polyphosphates (polyP) that can inhibit local mineralization, thereby preventing the formation of a ZCC at the interface. Thus, we hypothesize that coating CPP substrate with a layer of hydroxyapatite (HA) might prevent or limit this polyP release. To investigate this we tested both inorganic or organic sol-gel processing methods, asa barrier coating on CPP substrate to inhibit polyP release. Both types of coating supported the formation of ZCC in direct contact with the substrate, however the ZCC appeared more continuous in the tissue formed on the organic HA sol gel coated CPP. Tissues formed on coated substrates accumulated comparable quantities of extracellular matrix and mineral, but tissues formed on organic sol-gel (OSG)-coated substrates accumulated less polyP than tissues formed on inorganic sol-gel (ISG)-coated substrates. Constructs formed with OSG-coated CPP substrates had greater interfacial shear strength than those formed with ISG-coated and non-coated substrates. These results suggest that the OSG coating method can modify the location and distribution of ZCC and can be used to improve the mechanical integrity of tissue-engineered constructs formed on porous CPP substrates. Articular cartilage interfaces with bone through a zone of calcified cartilage. This study describes a method to generate an "osteochondral-like" implant that mimics this

  17. Edema surrounding calcified intracranial cysticerci: clinical manifestations, natural history, and treatment

    OpenAIRE

    Nash, Theodore

    2012-01-01

    Calcified granulomas are the most common radiological finding in neurocysticercosis (10–20% of endemic populations). A small proportion serves as foci of seizure activity, which results in large numbers of persons with epilepsy. Calcified granulomas are not all the same. Some demonstrate blood–brain barrier dysfunction (magnetic resonance imaging enhancement) most likely due to the presence of inflammation, visualizable scolices, and/or gliosis. About half the patients with a recent history o...

  18. Analysis of the movement of calcified lymph nodes during breathing

    International Nuclear Information System (INIS)

    Jenkins, Peter; Salmon, Clare; Mannion, Cathy

    2005-01-01

    Purpose: To identify and measure the respiratory-induced movement of calcified mediastinal lymph nodes. Methods and materials: Twenty-one patients receiving radiation therapy for primary lung or pleural tumors were noted to have calcification within one or more mediastinal lymph nodes. The breathing motion of 27 such nodes was measured with orthogonal fluoroscopic imaging during quiet respiration. Results: All 27 nodes showed some motion synchronous with breathing. The mean respiratory movement was 6.6 mm, 2.6 mm, and 1.4 mm in the craniocaudal, dorsoventral, and mediolateral planes, respectively. There was a significant difference in the amplitude of motion in the craniocaudal plane compared with movement in the other two directions (p < 0.001). No differences were seen in the movement of lymph nodes dependent on position within the mediastinum (supracarinal vs. infracarinal or hilar vs. mediastinal). Neither size of the primary tumor nor spirometric parameters were correlated with the amplitude of lymph node movement. Conclusions: Mediastinal lymph nodes move during breathing, and this needs to be accounted for when the internal margin component of the PTV is defined. The amplitude of this movement is anisotropic and seems to be less than that reported for primary lung tumors. This should permit a modest reduction in the margin allowed for breathing movement around involved mediastinal nodes, particularly in the mediolateral and dorsoventral planes

  19. Possible use of calcifying nanoparticles in immature root apex treatment

    Directory of Open Access Journals (Sweden)

    Mohammed S Alenazy

    2014-01-01

    Full Text Available Introduction: There are reports in the literature, which describe different techniques and materials in the challenging management of thin dentin walls and immature root apex. It has been suggested that calcifying nanoparticles (CNPs could be used in the management of these conditions. The Hypothesis: Compositionally modified CNPs made into a paste could become efficacious in managing thin dentin walls and immature root apex. Calcium and phosphate ions when mixed with CNPs could form a synthetic nanopaste that clinicians could use to manage thin dentin walls and to get a biological seal for immature root apex. Evaluation of the Hypothesis: CNPs can replicate and could facilitate the aggregations of calcium hydroxyapatite to produce a self-surrounding shell. These characteristics of CNPs could be used through their biomineralization process as initial nidus of calcification for further calcification progression to achieve total biological apical seal. If the hypothesis could be supported by biomineralization behavior of the paste (CNPs, Ca2 + , and PO4− , a new therapeutic agent would have been added to the armamentarium of endodontists. There is need for more in vivo and in vitro investigations of modified nanopaste to manage these conditions.

  20. Calcified epidural hematoma in pediatric age group: A report of two cases

    Directory of Open Access Journals (Sweden)

    A Trivedi

    2010-01-01

    Full Text Available The authors present a rare case of calcified (ossified chronic epidural hematoma developed in a six-and-a-half-year-old female patient who was operated for cerebellar astrocytoma 6 months earlier. There was no history of trauma. Ossified epidural hematoma was seen as an incidental finding in the follow-up in computed tomography scan after 6 months of primary glioma surgery. Ossified chronic epidural hematoma with thick collagenous wall and newly formed bone on dura was excised. The development of calcified chronic subdural hematoma after decompressive intracranial surgery is a well-known occurrence, but the fact that a calcified epidural hematoma, which is rare and which can also develop after decompressive surgery, and the occurrence of calcified (ossified epidural hematoma after postfossa a glioma surgery is not yet reported. The second case is a 9-year-old male anemic child with a history of fall while playing 5 months earlier who presented with headache of 3 months duration. He had bifrontal calcified epidural hematoma operated by craniotomy and excision of calcified dural edge.

  1. Impact of glucose intolerance on coronary calcified lesions evaluated using multislice computed tomography

    International Nuclear Information System (INIS)

    Nomura, Kyoko; Ohwaki, Kazuhiro; Yano, Eiji; Yamanouchi, Toshikazu; Kim, Gwang U.

    2007-01-01

    Metabolic syndrome has the unique concept that the common occurrence of individual disease components increases the risk of coronary artery disease (CAD). However, some studies suggest that the burden of different CAD risk factors is not equal, and focusing on the whole set of risk factors might neglect the impact of individual factors that could be useful targets for prophylactic therapies. The purpose of this study was to investigate the effect of glucose intolerance on CAD using multislice computed tomography (MSCT). Ninety-eight consecutive patients with at least one traditional CAD risk factor who visited a municipal hospital were enrolled in this study. The risk factors were impaired glucose tolerance (fasting glucose≥110 mg/dl or patients with diabetes), low high-density lipoprotein cholesterol (HDL-C, 25 kg/m 2 for men and >23 kg/m 2 for women). CAD was determined by the presence of either stenoses, non-calcified plaques or calcified lesions. The following risk factors were significantly related in univariate logistic models: glucose intolerance and coronary calcified lesions (p=0.001), and hypertriglycemia and non-calcified plaque lesions (p=0.048). Multivariate models showed that glucose intolerance was significantly associated with calcified lesions, even after adjustment for gender, age, low HDL-C, hypertriglycemia, hypertension, and obesity (p=0.018). Our results suggest that glucose intolerance might be closely related to the presence of coronary calcified lesions among traditional CAD risk factors. (author)

  2. Development, characterisation and biocompatibility testing of a cobalt-containing titanium phosphate-based glass for engineering of vascularized hard tissues

    Energy Technology Data Exchange (ETDEWEB)

    Lee, In-Ho [Department of Nanobiomedical Science and WCU Research Center of Nanobiomedical Science, Dankook University, Chungnam 330-714 (Korea, Republic of); Yu, Hye-sun [Department of Nanobiomedical Science and WCU Research Center of Nanobiomedical Science, Dankook University, Chungnam 330-714 (Korea, Republic of); Department of Biochemical Engineering, University College London, Torrington Place, London, WC1E 7JE (United Kingdom); Lakhkar, Nilay J. [Division of Biomaterials and Tissue Engineering, Eastman Dental Institute, University College London, 256 Gray' s Inn Road, London WC1X 8LD (United Kingdom); Kim, Hae-Won [Department of Nanobiomedical Science and WCU Research Center of Nanobiomedical Science, Dankook University, Chungnam 330-714 (Korea, Republic of); Institute of Tissue Regeneration Engineering (ITREN), Dankook University, Cheonan 330-714 (Korea, Republic of); Department of Biomaterials Science, College of Dentistry, Dankook University, Cheonan 330-714 (Korea, Republic of); Gong, Myoung-Seon [Department of Nanobiomedical Science and WCU Research Center of Nanobiomedical Science, Dankook University, Chungnam 330-714 (Korea, Republic of); Institute of Tissue Regeneration Engineering (ITREN), Dankook University, Cheonan 330-714 (Korea, Republic of); Knowles, Jonathan C. [Department of Nanobiomedical Science and WCU Research Center of Nanobiomedical Science, Dankook University, Chungnam 330-714 (Korea, Republic of); Division of Biomaterials and Tissue Engineering, Eastman Dental Institute, University College London, 256 Gray' s Inn Road, London WC1X 8LD (United Kingdom); Wall, Ivan B., E-mail: i.wall@ucl.ac.uk [Department of Nanobiomedical Science and WCU Research Center of Nanobiomedical Science, Dankook University, Chungnam 330-714 (Korea, Republic of); Department of Biochemical Engineering, University College London, Torrington Place, London, WC1E 7JE (United Kingdom)

    2013-05-01

    There is a continuing need to develop scaffold materials that can promote vascularisation throughout the tissue engineered construct. This study investigated the effect of cobalt oxide (CoO) doped into titanium phosphate glasses on material properties, biocompatibility and vascular endothelial growth factor (VEGF) secretion by osteoblastic MG63 cells. Glasses composed of (P{sub 2}O{sub 5}){sub 45}(Na{sub 2}O){sub 20}(TiO{sub 2}){sub 05}(CaO){sub 30−x}(CoO){sub x}(x = 0, 5, 10, and 15 mol%) were fabricated and the effect of Co on physicochemical properties including density, glass transition temperature (T{sub g}), degradation rate, ion release, and pH changes was assessed. The results showed that incorporation of CoO into the glass system produced an increase in density with little change in T{sub g}. It was then confirmed that the pH did not change significantly when CoO was incorporated in the glass, and stayed constant at around 6.5–7.0 throughout the dissolution study period of 336 h. Ion release results followed a specific pattern with increasing amounts of CoO. In general, although incorporation of CoO into a titanium phosphate glass increased its density, other bulk and surface properties of the glass did not show any significant changes. Cell culture studies performed using MG63 cells over a 7-day period indicated that the glasses provide a stable surface for cell attachment and are biocompatible. Furthermore, VEGF secretion was significantly enhanced on all glasses compared with standard tissue culture plastic and Co doping enhanced this effect further. In conclusion, the developed Co-doped glasses are stable and biocompatible and thus offer enhanced potential for engineering vascularized tissue. - Highlights: ► Phosphate-based glasses can be successfully doped with cobalt oxide. ► The resulting glass is highly stable with low degradation rate. ► Co-doped glasses are biocompatible but do not favour cell proliferation. ► Osteoblastic MG63 cells

  3. Optical coherence tomography assessment of the mechanistic effects of rotational and orbital atherectomy in severely calcified coronary lesions.

    Science.gov (United States)

    Kini, Annapoorna S; Vengrenyuk, Yuliya; Pena, Jacobo; Motoyama, Sadako; Feig, Jonathan E; Meelu, Omar A; Rajamanickam, Anitha; Bhat, Arjun M; Panwar, Sadik; Baber, Usman; Sharma, Samin K

    2015-11-15

    This study sought to assess the mechanistic effect of rotational atherectomy (RA) and orbital atherectomy (OA) on heavily calcified coronary lesions and subsequent stent placement using optical coherence tomography (OCT). RA and OA are two main approaches to ablate coronary calcium. While small case reports have described the mechanistic effect of RA in calcified coronary lesions, there has been no imaging study to assess the effect of OA on coronary artery architecture and/or compare the effects of two atherectomy devices. This study analyzed 20 consecutive patients with OCT imaging performed after atherectomy and after stent implantation, RA (n = 10) and OA (n = 10). Postatherectomy OCT analysis identified tissue modification with deep dissections in around a third of lesions after RA and OA; however, post OA dissections ("lacunae") were significantly deeper (1.14 vs. 0.82 mm, P = 0.048). Post OA/RA lesions with dissections had significantly higher percentage of lipid rich plaques and smaller calcification arcs as compared to plaques without dissections. Stents after OA were associated with a significantly lower percent of stent strut malapposition than post RA stents (4.36 vs. 8.02%, P = 0.038). Although the incidence of dissections was comparable between RA and OA cases, OA resulted in deeper tissue modifications (lacunae) as shown by OCT imaging. The finding might provide an explanation for a better stent apposition after OA as compared to RA. Their impact on long-term outcome needs to be determined. © 2015 Wiley Periodicals, Inc.

  4. Physicochemical and mechanical properties of freeze cast hydroxyapatite-gelatin scaffolds with dexamethasone loaded PLGA microspheres for hard tissue engineering applications

    Energy Technology Data Exchange (ETDEWEB)

    Ghorbani, Farnaz, E-mail: Farnaz_ghorbani.1991@yahoo.com [Department of Biomedical Engineering, Tehran Science and Research Branch, Islamic Azad University, P. O. Box: 4515/775, Tehran (Iran, Islamic Republic of); Nojehdehian, Hanieh, E-mail: hanieh.nojehdehyan@gmail.com [Department of Dental Materials, School of Dentistry, Shahid Beheshti University of Medical Sciences, P.O. Box: 1983963113, Tehran (Iran, Islamic Republic of); Zamanian, Ali, E-mail: a-zamanian@merc.ac.ir [Biomaterials Research Group, Department of Nanotechnology and Advanced Materials, Materials and Energy Research Center, P.O. Box: 14155-4777, Tehran (Iran, Islamic Republic of)

    2016-12-01

    Hydroxyapatite (HA)-gelatin scaffolds incorporated with dexamethasone-loaded polylactic-co-glycolic acid (PLGA) microspheres were synthesized by freeze casting technique. Scanning electron microscopy (SEM) micrographs demonstrated a unidirectional microstructure and a decrease in the pore size as a function of temperature gradient. Higher amounts of HA resulted in a decrease in the pore size. According to the results, at lower cooling rates, the formation of a lamellar structure decreased the mechanical strength, but at the same time, enhanced the swelling ratio, biodegradation rate and drug release level. On the other hand, higher weight ratios of HA increased the compressive strength, and reduced the swelling ratio, biodegradation rate and drug release level. The results obtained by furrier transform infrared spectroscopy (FTIR) and bioactivity analysis illustrated that the interactions of the materials support the apatite formation in the simulated body fluid (SBF) solution. Based on the obtained results, the synthesized composite scaffolds have the necessary mechanical and physicochemical features to support the regeneration of defects and to maintain their stability during the neo-tissue formation. - Highlights: • Freeze casting technique created unidirectional lamellar type microstructure. • Unidirectional microstructure of samples improved mechanical behavior, absorption, biodegradation rate and release behavior. • Hydroxyapatite-gelatin scaffolds demonstrated bioactive behavior and support new apatite layer formation. • Controlled release rate provided by dexamethasone loaded PLGA microspheres.

  5. Physicochemical and mechanical properties of freeze cast hydroxyapatite-gelatin scaffolds with dexamethasone loaded PLGA microspheres for hard tissue engineering applications.

    Science.gov (United States)

    Ghorbani, Farnaz; Nojehdehian, Hanieh; Zamanian, Ali

    2016-12-01

    Hydroxyapatite (HA)-gelatin scaffolds incorporated with dexamethasone-loaded polylactic-co-glycolic acid (PLGA) microspheres were synthesized by freeze casting technique. Scanning electron microscopy (SEM) micrographs demonstrated a unidirectional microstructure and a decrease in the pore size as a function of temperature gradient. Higher amounts of HA resulted in a decrease in the pore size. According to the results, at lower cooling rates, the formation of a lamellar structure decreased the mechanical strength, but at the same time, enhanced the swelling ratio, biodegradation rate and drug release level. On the other hand, higher weight ratios of HA increased the compressive strength, and reduced the swelling ratio, biodegradation rate and drug release level. The results obtained by furrier transform infrared spectroscopy (FTIR) and bioactivity analysis illustrated that the interactions of the materials support the apatite formation in the simulated body fluid (SBF) solution. Based on the obtained results, the synthesized composite scaffolds have the necessary mechanical and physicochemical features to support the regeneration of defects and to maintain their stability during the neo-tissue formation. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Ocean acidification and calcifying reef organisms: a mesocosm investigation

    Science.gov (United States)

    Jokiel, P. L.; Rodgers, K. S.; Kuffner, I. B.; Andersson, A. J.; Cox, E. F.; MacKenzie, F. T.

    2008-09-01

    A long-term (10 months) controlled experiment was conducted to test the impact of increased partial pressure of carbon dioxide ( pCO2) on common calcifying coral reef organisms. The experiment was conducted in replicate continuous flow coral reef mesocosms flushed with unfiltered sea water from Kaneohe Bay, Oahu, Hawaii. Mesocosms were located in full sunlight and experienced diurnal and seasonal fluctuations in temperature and sea water chemistry characteristic of the adjacent reef flat. Treatment mesocosms were manipulated to simulate an increase in pCO2 to levels expected in this century [midday pCO2 levels exceeding control mesocosms by 365 ± 130 μatm (mean ± sd)]. Acidification had a profound impact on the development and growth of crustose coralline algae (CCA) populations. During the experiment, CCA developed 25% cover in the control mesocosms and only 4% in the acidified mesocosms, representing an 86% relative reduction. Free-living associations of CCA known as rhodoliths living in the control mesocosms grew at a rate of 0.6 g buoyant weight year-1 while those in the acidified experimental treatment decreased in weight at a rate of 0.9 g buoyant weight year-1, representing a 250% difference. CCA play an important role in the growth and stabilization of carbonate reefs, so future changes of this magnitude could greatly impact coral reefs throughout the world. Coral calcification decreased between 15% and 20% under acidified conditions. Linear extension decreased by 14% under acidified conditions in one experiment. Larvae of the coral Pocillopora damicornis were able to recruit under the acidified conditions. In addition, there was no significant difference in production of gametes by the coral Montipora capitata after 6 months of exposure to the treatments.

  7. Persistent Seroconversion after Accidental Eye Exposure to Calcifying Nanoparticles

    Science.gov (United States)

    Ciftcioglu, Neva; Aho, Katja M.; McKay, David S.; Kajander, E. Olavi

    2007-01-01

    Biosafety of nanomaterials has attracted much attention recently. We report here a case where accidental human eye exposure to biogenic nanosized calcium phosphate in the form of calcifying nanoparticles (CNP) raised a strong IgG immune response against proteins carried by CNP. The antibody titer has persisted over ten years at the high level. The IgG was detected by ELISA using CNPs propagated in media containing bovine and human serum as antigen. The exposure incident occurred to a woman scientist (WS) at a research laboratory in Finland at 1993. CNP, also termed "nanobacteria", is a unique self-replicating agent that has not been fully characterized and no data on biohazards were available at that time. Before the accident, her serum samples were negative for both CNP antigen and anti-CNP antibody using specific ELISA tests (Nanobac Oy, Kuopio, Finland). The accident occurred while WS was harvesting CNP cultures. Due to a high pressure in pipetting, CNP pellet splashed into her right eye. Both eyes were immediately washed with water and saline. The following days there was irritation and redness in the right eye. These symptoms disappeared within two weeks without any treatment. Three months after the accident, blood and urine samples of WS were tested for CNP cultures (2), CNP-specific ELISA tests, and blood cell counts. Blood cell counts were normal, CNP antigen and culture tests were negative. A high IgG anti-CNP antibody titer was detected (see Figure). The antibodies of this person have been used thereafter as positive control and standard in ELISA manufacturing (Nano-Sero IgG ELISA, Nanobac Oy, Kuopio, Finland).

  8. Ocean acidification and calcifying reef organisms: A mesocosm investigation

    Science.gov (United States)

    Jokiel, P.L.; Rodgers, K.S.; Kuffner, I.B.; Andersson, A.J.; Cox, E.F.; MacKenzie, F.T.

    2008-01-01

    A long-term (10 months) controlled experiment was conducted to test the impact of increased partial pressure of carbon dioxide (pCO2) on common calcifying coral reef organisms. The experiment was conducted in replicate continuous flow coral reef mesocosms flushed with unfiltered sea water from Kaneohe Bay, Oahu, Hawaii. Mesocosms were located in full sunlight and experienced diurnal and seasonal fluctuations in temperature and sea water chemistry characteristic of the adjacent reef flat. Treatment mesocosms were manipulated to simulate an increase in pCO2 to levels expected in this century [midday pCO2 levels exceeding control mesocosms by 365 ?? 130 ??atm (mean ?? sd)]. Acidification had a profound impact on the development and growth of crustose coralline algae (CCA) populations. During the experiment, CCA developed 25% cover in the control mesocosms and only 4% in the acidified mesocosms, representing an 86% relative reduction. Free-living associations of CCA known as rhodoliths living in the control mesocosms grew at a rate of 0.6 g buoyant weight year-1 while those in the acidified experimental treatment decreased in weight at a rate of 0.9 g buoyant weight year-1, representing a 250% difference. CCA play an important role in the growth and stabilization of carbonate reefs, so future changes of this magnitude could greatly impact coral reefs throughout the world. Coral calcification decreased between 15% and 20% under acidified conditions. Linear extension decreased by 14% under acidified conditions in one experiment. Larvae of the coral Pocillopora damicornis were able to recruit under the acidified conditions. In addition, there was no significant difference in production of gametes by the coral Montipora capitata after 6 months of exposure to the treatments. ?? 2008 Springer-Verlag.

  9. Calcified Plaque of Coronary Artery: Factors Influencing Overestimation of Coronary Artery Stenosis on Coronary CT Angiography

    International Nuclear Information System (INIS)

    Kim, Mok Hee; Kim, Yun Hyeon; Choi, Song; Seon, Hyun Ju; Jeong, Gwang Woo; Park, Jin Gyoon; Kang, Heoung Keun; Ko, Joon Seok

    2010-01-01

    To assess the influence of calcified plaque characteristics on the overestimation of coronary arterial stenosis on a coronary CT angiography (CCTA). The study included 271 coronary arteries with calcified plaques identified by CCTA, and based on 928 coronary arteries from 232 patients who underwent both CCTA and invasive coronary angiography (ICA). Individual coronary arteries were classified into two groups by agreement based on the degree of stenosis from each CCTA and ICA: 1) group A includes patients with concordant CCTA and ICA results and, 2) group B includes patients with an overestimation of CCTA compared to ICA. Parameters including total calcium score, calcium score of an individual coronary artery, calcium burden number of an individual coronary artery, and the density of each calcified plaque (calcium score / number of calcium burden) for each individual coronary artery were compared between the two groups. Of the 271 coronary arteries, 164 (60.5%) were overestimated on CCTA. The left anterior descending artery (LAD) had a significantly low rate of overestimation (47.1%) compared to the other coronary arteries (p=0.001). No significant differences for total calcium score, calcium score of individual coronary artery, and the density of each calcified plaque from individual coronary arteries between two groups was observed. However, a decreasing tendency for the rate of overestimation on CCTA was observed with an increase in calcium burden of individual coronary arteries (p<0.05). The evaluation of coronary arteries suggests that the degree of coronary arterial stenosis had a tendency to be overestimated by calcified plaques on CCTA. However, the rate of overestimation for the degree of coronary arterial stenosis by calcified plaques was not significantly influenced by total calcium score, calcium score of individual coronary artery, and density of each calcified plaque

  10. Iterative model reconstruction reduces calcified plaque volume in coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Károlyi, Mihály, E-mail: mihaly.karolyi@cirg.hu [MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st, 1122, Budapest (Hungary); Szilveszter, Bálint, E-mail: szilveszter.balint@gmail.com [MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st, 1122, Budapest (Hungary); Kolossváry, Márton, E-mail: martonandko@gmail.com [MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st, 1122, Budapest (Hungary); Takx, Richard A.P, E-mail: richard.takx@gmail.com [Department of Radiology, University Medical Center Utrecht, 100 Heidelberglaan, 3584, CX Utrecht (Netherlands); Celeng, Csilla, E-mail: celengcsilla@gmail.com [MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st, 1122, Budapest (Hungary); Bartykowszki, Andrea, E-mail: bartyandi@gmail.com [MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st, 1122, Budapest (Hungary); Jermendy, Ádám L., E-mail: adam.jermendy@gmail.com [MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st, 1122, Budapest (Hungary); Panajotu, Alexisz, E-mail: panajotualexisz@gmail.com [MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st, 1122, Budapest (Hungary); Karády, Júlia, E-mail: karadyjulia@gmail.com [MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st, 1122, Budapest (Hungary); and others

    2017-02-15

    Objective: To assess the impact of iterative model reconstruction (IMR) on calcified plaque quantification as compared to filtered back projection reconstruction (FBP) and hybrid iterative reconstruction (HIR) in coronary computed tomography angiography (CTA). Methods: Raw image data of 52 patients who underwent 256-slice CTA were reconstructed with IMR, HIR and FBP. We evaluated qualitative, quantitative image quality parameters and quantified calcified and partially calcified plaque volumes using automated software. Results: Overall qualitative image quality significantly improved with HIR as compared to FBP, and further improved with IMR (p < 0.01 all). Contrast-to-noise ratios were improved with IMR, compared to HIR and FBP (51.0 [43.5–59.9], 20.3 [16.2–25.9] and 14.0 [11.2–17.7], respectively, all p < 0.01) Overall plaque volumes were lowest with IMR and highest with FBP (121.7 [79.3–168.4], 138.7 [90.6–191.7], 147.0 [100.7–183.6]). Similarly, calcified volumes (>130 HU) were decreased with IMR as compared to HIR and FBP (105.9 [62.1–144.6], 110.2 [63.8–166.6], 115.9 [81.7–164.2], respectively, p < 0.05 all). High-attenuation non-calcified volumes (90–129 HU) yielded similar values with FBP and HIR (p = 0.81), however it was lower with IMR (p < 0.05 both). Intermediate- (30–89 HU) and low-attenuation (<30 HU) non-calcified volumes showed no significant difference (p = 0.22 and p = 0.67, respectively). Conclusions: IMR improves image quality of coronary CTA and decreases calcified plaque volumes.

  11. Case report - calcification of the medial collateral ligament of the knee with simultaneous calcifying tendinitis of the rotator cuff

    OpenAIRE

    Kamawal, Yama; Steinert, Andre F; Holzapfel, Boris M; Rudert, Maximilian; Barthel, Thomas

    2017-01-01

    Background Calcification of the medial collateral ligament (MCL) of the knee is a very rare disease. We report on a case of a patient with a calcifying lesion within the MCL and simultaneous calcifying tendinitis of the rotator cuff in both shoulders. Case presentation Calcification of the MCL was diagnosed both via x-ray and magnetic resonance imaging (MRI) and was successfully treated surgically. Calcifying tendinitis of the rotator cuff was successfully treated applying conservative method...

  12. Fractures after multimodality treatment of soft tissue sarcomas with isolated limb perfusion and radiation; likely to occur and hard to heal.

    Science.gov (United States)

    Seinen, J M; Jutte, P C; Been, L B; Pras, E; Hoekstra, H J

    2018-04-24

    Treatment associated fractures (TAFs) are known severe side effects after surgery and radiotherapy for soft tissue sarcoma (STS). There is no literature about TAF after multimodality treatment with isolated limb perfusion (ILP) for locally advanced STS. This study aimed to analyze predictive factors, treatment and outcome for TAF after multimodality treatment with ILP. Out of 126 consecutive patients undergoing ILP after 1991 till now, 25 patients were excluded due to no surgery or direct amputation at initial surgery. Therefore, 101 patients were at risk and 12 developed a TAF (12%). The majority of tumors was located at the upper leg and knee (N = 60), and 11 patients developed a TAF (18%) after median 28 (5-237) months. Twenty-five tumors were located at the lower leg, and 1 patient developed a TAF after 12 months (4%). No patients with a tumor at the upper extremities (N = 16) developed a TAF. Ten out of 12 patients with a fracture received adjuvant RT with a dose of 50 Gy, and a median boost dose of 18 (10-20) Gy. Predictive factors were periosteal stripping, age over 65 years at time of treatment and tumor size after ILP ≥10 cm. Multivariate analysis showed periosteal stripping and tumor size after ILP ≥10 cm as significant predictive factors. The majority of the fractures were treated with intramedullary nailing. Only one of 12 patients without radiotherapy reached bone union (8%). The median survival after developing TAF was 18 (1-195) months. The overall risk of TAF after multimodality treatment with ILP was relatively high with 15% at ten years. The incidence of TAF for patients with tumors located at the thigh and knee after resection with periosteal stripping and radiotherapy was even >50%. The treatment of these fractures is challenging due to the high non-union rate, requiring an extensive orthopedic oncological TAF experience. Copyright © 2018 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical

  13. High-speed scanning ablation of dental hard tissues with a λ=9.3-μm CO2 laser: heat accumulation and peripheral thermal damage

    Science.gov (United States)

    Nguyen, Daniel; Staninec, Michal; Lee, Chulsung; Fried, Daniel

    2010-02-01

    A mechanically scanned CO2 laser operated at high laser pulse repetition rates can be used to rapidly and precisely remove dental decay. This study aims to determine whether these laser systems can safely ablate enamel and dentin without excessive heat accumulation and peripheral thermal damage. Peripheral thermal damage can adversely impact the mechanical strength of the irradiated tissue, particularly for dentin, and reduce the adhesion characteristics of the modified surfaces. Samples were derived from noncarious extracted molars. Pulpal temperatures were recorded using microthermocouples situated at the pulp chamber roof of samples (n=12), which were occlusally ablated using a rapid-scanning, water-cooled 300 Hz CO2 laser over a two minute time course. The mechanical strength of facially ablated dentin (n=10) was determined via four-point bend test and compared to control samples (n=10) prepared with 320 grit wet sand paper to simulate conventional preparations. Composite-to-enamel bond strength was measured via single-plane shear test for ablated/non-etched (n=10) and ablated/acid-etched (n=8) samples and compared to control samples (n=9) prepared by 320 grit wet sanding. Thermocouple measurements indicated that the temperature remained below ambient temperature at 19.0°C (s.d.=0.9) if water-cooling was used. There was no discoloration of either dentin and enamel, the treated surfaces were uniformly ablated and there were no cracks observable on the laser treated surfaces. Fourpoint bend tests yielded mean mechanical strengths of 18.2 N (s.d.=4.6) for ablated dentin and 18.1 N (s.d.=2.7) for control (p>0.05). Shear tests yielded mean bond strengths of 31.2 MPa (s.d.=2.5, penamel without excessive heat accumulation and with minimal thermal damage. It is not clear whether the small (16%) but statistically significant reduction in the shear bond strength to enamel is clinically significant since the mean shear bond strength exceeded 30 MPa.

  14. Estudio in vitro sobre los efectos de la cocaína sobre los tejidos duros del diente In vitro study on the effects of cocaine on the hard tissues of the tooth

    Directory of Open Access Journals (Sweden)

    Eduvigis Solórzano Navarro

    2008-12-01

    Full Text Available El uso de los derivados de la cocaína es un problema de salud pública en continuo crecimiento. Estas drogas son frecuentemente frotadas sobre la mucosa gingival, pero sus efectos son poco conocidos y de difícil diagnóstico. Con este trabajo se pretende demostrar in vitro, que la aplicación por frotación de la cocaína sobre la superficie dentaria produce erosión del esmalte. Se seleccionaron 30 dientes sanos, distribuidos aleatoriamente en 3 grupos, a los cuales se frotó sobre la superficie vestibular clorhidrato de cocaína, basuco y limón (grupo control respectivamente, durante 40 semanas. Las lesiones más características observadas fueron fractura y pérdida de sustancia dura, demostrando así que la aplicación tópica y continua de drogas en cavidad bucal produce lesiones en los tejidos duros del diente.The use of cocaine derivatives is an increasingly growing public health problem. These drugs are frequently rubbed on the gingival mucosa, but their efffects are little known and difficult to be diagnosed. This paper pretends to prove in vitro that the rubbing of cocaine on the dental surface produces enamel erosion. 30 healthy teeth were selected and distributed at random into 3 groups that were rubbed cocaine hydrochloride, bazuko and lemon (control group on the vestibular surface, respectively, during 40 weeks. The most observed characteristic lesions were fracture and loss of the dental hard substance, which showed that the topical and continual application of drugs on the oral cavity causes lesions in the hard tissues of the tooth.

  15. Secondary adult encephalocele with abscess formation of calcified frontal sinus mucocele.

    Science.gov (United States)

    Oh, Byeong Ho; Lee, Ok-Jun; Park, Young Seok

    2016-07-01

    Although encephalocele is a rare congenital abnormality, secondary encephalocele is extremely rare and can cause fatal complications. Here, we report a case of secondary encephalocele caused by frontal sinus wall defect due to chronic sinusitis, which was completely removed by cranialization with autologous bone graft. A 50-year-old man with a 10-year history of chronic sinusitis visited our hospital due to suddenly altered mentality characterized by stupor. Computerized tomography scanning and magnetic resonance imaging revealed an enlarged left frontal sinus with sinusitis. The frontal sinus cavity was calcified, and the left frontal lobe had herniated into the cavity accompanied by yellow pus. A large dural defect was also found around the frontal sinus area. After removal of the abscess and some of the frontal lobe, frontal skull base repair by cranialization was performed using autologous bone graft. Streptococcus pneumoniae was cultured from the cerebrospinal fluid (CSF), necessitating treatment with antibiotics. After the operation, the mental status of the patient improved and no CSF leakage was observed. In addition to correct diagnosis and early treatment including antibiotics, the surgical repair of defects is needed in patients with secondary encephalocele to prevent further episodes of meningitis. Surgical correction of frontal sinus encephalocele can be achieved through bifrontal craniotomy or endoscopic transnasal repair. If a patient has CSF leakage, open craniotomy may facilitate repair of the dural defect and allow for cranialization of the sinus. Removal of dysplastic herniated brain tissue and cranialization of the frontal sinus may be a good option for treating secondary encephalocele and its associated complications, including meningitis, abscess formation, and infarction of the herniated brain parenchyma.

  16. A Case of Old Calcifying Epithelioma Processed Symptomless over 40 Years

    Directory of Open Access Journals (Sweden)

    Shinji Yamaguchi

    2013-01-01

    Full Text Available Calcifying epithelioma, a benign tumor derived from the hair apparatus and consisted of hair matrix cells, is relatively prevalent in females. We report a case of right preauricular calcifying epithelioma that was incidentally detected at the examination of multiple facial fractures and became an old lesion without symptoms for 40 years. The patient who was a 42-year-old male visited our department for the first time in October 2011 with a chief complaint of multiple facial fractures. Radiographic imaging demonstrated fracture lines at the anterior and posterior walls of the left maxillary sinus and zygomatic arch and revealed a mass at a right preauricular area. The extraction was performed under general anaesthesia. No recurrence has been observed 15 months after surgery. We also reviewed the literature of calcifying epithelioma.

  17. Effect of Irradiation on Apoptosis, Cell Cycle Arrest and Calcified Nodule Formation of Rat Calvarial Osteoblast

    International Nuclear Information System (INIS)

    Lee, Young Mi; Choi, Hang Moon; Heo, Min Suk; Lee, Sam Sun; Choi, Soon Chul; Park, Tae Won

    2000-01-01

    The study was aimed to detect the induction of apoptosis, cell cycle arrest and calcified nodule formation after irradiation on primarily cultured osteoblasts. Using rat calvarial osteoblasts, the effects of irradiation on apoptosis, cell cycle arrest, and calcified nodule formation were studied. The single irradiation of 10, 20 Gy was done with 5.38 Gy/min dose rate using the 137 Cs cell irradiator at 4th and 14th day of culture. Apoptosis induction and cell cycle arrest were assayed by the flow cytometry at 1, 2, 3, and 4 days after irradiation. The formation of calcified nodules was observed by alizarin red staining at 1, 3, 10, 14 days after irradiation at 4th day of culture, and at 1, 4, 5 days after irradiation at 14th day of culture. Apoptosis was not induced by 10 or 20 Gy independent of irradiation and culture period. Irradiation did not induced G1 arrest in post-irradiated osteoblasts. After irradiation at 4th-day of culture, G2 arrest was induced but it was not statistically significant after irradiation at 14th-day of culture. In the case of irradiated cells at 4th day of culture, calcified nodules were not formed and at 14th-day of culture after irradiation, calcified nodule formation did not affected. Taken together, these results suggest that irradiation at the dose of 10-20 Gy would not affect apoptosis induction of osteoblasts. Cell cycle and calcified nodule formation were influenced by the level of differentiation of osteblasts.

  18. Novel calcified gum Arabic porous nano-composite scaffold for bone tissue regeneration.

    Science.gov (United States)

    Hadavi, M; Hasannia, S; Faghihi, Sh; Mashayekhi, F; Zadeh, H H; Mostofi, S B

    2017-07-08

    The aim of this study was to investigate the biomechanical and biological properties of a nanocomposite scaffold containing both mineral and polysaccharide constituents. Hydroxyapatite nanoparticles (n-HA) was synthesized from dead abra ovata shells using wet chemical methods and was used in different ratios in concert with gum Arabic, a branched plant polysaccharide. N-HA/gum nanocomposite was fabricated with freeze-drying process and characterized by FTIR and SEM for chemical structure and morphology. Porosity was estimated using liquid substitution method. The scaffold mechanical properties were evaluated by compressive test measurement. Osteogenic differentiation was assessed using alkaline phosphatase production and biomineralization was evaluated using Alizarin red assay. Results demonstrated that the hydroxyapatite/gum Arabic nanocomposite had favorable biocompatibility and a similar structure to natural bone matrix. Porous nanocomposite possessed macropore networks with a porosity 87-93% and mean pore size ranging between 164 and 230 μm. The gum/HA with a ratio of 50% w/w HA had the highest compressive modulus of ∼75.3 MPa Pa (MPa) and the ultimate compressive stress of ∼16.6 MPa. C2C12 cells cultured on a scaffold with higher percentage (40 and 50 w/w) of HA demonstrated increased ALP levels and calcium deposition. The data from the present study demonstrated significant changes to the biomechanical properties and osteoconductivity of the nanocomposite scaffold by modulating its mineral content. Nanocomposite scaffolds containing gum and n-HA of 40-50% exhibited highest mechanical properties, as well as supported increased biomineralization. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Non-neoplastic calcified tissue pathologies among radium workers and plutonium injectees

    International Nuclear Information System (INIS)

    Stebbings, J.H.

    1997-01-01

    Two human studies of deterministic effects of radium and plutonium are summarized. Histopathology data from femurs of New Jersey radium workers demonstrate effects of radium at ∼0.8 Gy skeletal dose. Toxicity ratio data from beagles suggest equivalent histopathological effects from 239 Pu may occur in humans at skeletal doses of ∼0.12 Gy in compact bone or at ∼0.01-0.02 Gy in spongy bone. These results support observations that subjects injected with plutonium in the 1940s showed bone changes typical of alpha radiation exposures, extensive osteoporosis with related fractures, and hearing disorders or vertigo related to bone damage and/or middle ear inflammation, all findings suggested by the clinical radium literature. A probable case of extensive pathologic calcification from a plutonium injection also occurred. In two cases suspect findings occurred at skeletal doses of ∼0.05 Gy. It is hypothesized that subjects with collagen disorders and uremic insufficiencies, as well as females late in life, form subpopulations susceptible to non-stochastic effects of internal alpha-emitters. In general, bone fractures late in life secondary to osteoporosis are associated with increased disability, increased risk of institutionalization, and with diminished survival rates. (author)

  20. New insights into the functions of enamel matrices in calcified tissues

    Directory of Open Access Journals (Sweden)

    Satoshi Fukumoto

    2014-05-01

    Full Text Available Ameloblasts secrete enamel matrix proteins, including amelogenin, ameloblastin, enamelin, amelotin, and Apin/odontogenic ameloblast-associated protein (Apin/ODAM. Amelogenin is the major protein component of the enamel matrix. Amelogenin, ameloblastin, and enamelin are expressed during the secretory stage of ameloblast, while amelotin and Apin/ODAM are expressed during the maturation. Amelogenin and ameloblastin are also expressed in osteoblasts, and they regulate bone formation. In addition, recent studies show the importance of protein–protein interactions between enamel matrix components for enamel formation. In a mouse model mimicking a mutation of the amelogenin gene in amelogenesis imperfect (AI in humans, the mutated amelogenin forms a complex with ameloblastin, which accumulates in the endoplasmic reticulum/Golgi apparatus and causes ameloblast dysfunction resulting in AI phenotypes. Ameloblastin is a cell adhesion molecule that regulates cell proliferation. It inhibits odontogenic tumor formation and regulates osteoblast differentiation through binding to CD63. Amelotin interacts with Apin/ODAM, but not ameloblastin, while Apin/ODAM binds to ameloblastin. These interactions may be important for enamel mineralization during amelogenesis. The enamel matrix genes are clustered on human chromosome 4 except for the amelogenin genes located on the sex chromosomes. Genes for these enamel matrix proteins evolved from a common ancestral gene encoding secretory calcium-binding phosphoprotein.

  1. Melan-A/Mart-1- or HMB-45-positive melanocytes are not present in calcifying cystic odontogenic tumors (calcifying odontogenic cysts): a study in 13 Caucasian patients.

    Science.gov (United States)

    Tosios, Konstantinos I; Prountzos, Nikolaos; Katsoulas, Nikolaos; Koutlas, Ioannis G; Sklavounou-Andrikopoulou, Alexandra

    2012-03-01

    Melanin pigment and melanocytes may be found in odontogenic cysts and tumors, particularly calcifying cystic odontogenic tumor (CCOT). In the present study we investigated the immunohistochemical expression of the Melan-A/Mart-1 and HMB-45 antigens in 13 Caucasians patients with CCOT. Melan-A/Mart-1- and HMB-45-positive melanocytes were not seen in any of the cases. Our findings are in agreement with the assumption that pigmentation in odontogenic lesions may be a racial phenomenon.

  2. High Density Infill in Cracks and Protrusions from the Articular Calcified Cartilage in Osteoarthritis in Standardbred Horse Carpal Bones

    Directory of Open Access Journals (Sweden)

    Sheila Laverty

    2015-04-01

    Full Text Available We studied changes in articular calcified cartilage (ACC and subchondral bone (SCB in the third carpal bones (C3 of Standardbred racehorses with naturally-occurring repetitive loading-induced osteoarthritis (OA. Two osteochondral cores were harvested from dorsal sites from each of 15 post-mortem C3 and classified as control or as showing early or advanced OA changes from visual inspection. We re-examined X-ray micro-computed tomography (µCT image sets for the presence of high-density mineral infill (HDMI in ACC cracks and possible high-density mineralized protrusions (HDMP from the ACC mineralizing (tidemark front (MF into hyaline articular cartilage (HAC. We hypothesized and we show that 20-µm µCT resolution in 10-mm diameter samples is sufficient to detect HDMI and HDMP: these are lost upon tissue decalcification for routine paraffin wax histology owing to their predominant mineral content. The findings show that µCT is sufficient to discover HDMI and HDMP, which were seen in 2/10 controls, 6/9 early OA and 8/10 advanced OA cases. This is the first report of HDMI and HDMP in the equine carpus and in the Standardbred breed and the first to rely solely on µCT. HDMP are a candidate cause for mechanical tissue destruction in OA.

  3. Ghost cells in pilomatrixoma, craniopharyngioma, and calcifying cystic odontogenic tumor: histological, immunohistochemical, and ultrastructural study.

    Science.gov (United States)

    Rumayor, Alicia; Carlos, Román; Kirsch, Hernán Molina; de Andrade, Bruno A Benevenuto; Romañach, Mario J; de Almeida, Oslei Paes

    2015-04-01

    Pilomatrixoma, craniopharyngioma, and calcifying cystic odontogenic tumor are the main entities presenting ghost cells as an important histological feature, in spite their quite different clinical presentation; it seems that they share a common pathway in the formation of these cells. The aim of this study is to examine and compare the characteristics of ghost and other cells that form these lesions. Forty-three cases including 21 pilomatrixomas, 14 craniopharyngiomas, and eight calcifying cystic odontogenic tumors were evaluated by immunohistochemistry for cytokeratins, CD138, β-catenin, D2-40, Glut-1, FAS, CD10 and also by scanning electron microscopy. The CKs, CD138, β-catenin, Glut-1, FAS, and CD10 were more often expressed by transitional cells of craniopharyngioma and calcifying cystic odontogenic tumor, compared with pilomatrixoma. Basaloid cells of pilomatrixoma showed strong positivity for CD138 and CD10. Differences on expression pattern were identified in transitional and basal cells, as ghost cells were negative for most antibodies used, except by low expression for cytokeratins. By scanning electron microscopy, the morphology of ghost cells were similar in their fibrillar cytoplasm, but their pattern varied from sheets in pilomatrixoma to small clusters in craniopharyngioma and calcifying cystic odontogenic tumor. Mechanisms involved in formation of ghost cells are unknown, but probably they follow different pathways as protein expression in the basal/transitional cells was not uniform in the three tumors studied. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. In Vivo Remineralization of Artificial Carious Lesions using Calcifying Solution and Fluoride Solution

    Directory of Open Access Journals (Sweden)

    Els Sunarsih Budipramana

    2015-10-01

    Full Text Available The remineralization potential of fluoride and calcifying solution was studiedas in situ model. Matched enamel discs of artifically demineralized human enamel were attached to an acrylic mandibular removable appliance of 6 adult volunteers who rinsed their mouth with a solution containing either 50 ppm F-, 200 ppm F- in amine fluoride, calcifying solution (formula BR21 or placebo as a control. The volunteers were asked to rinse 3 times a day for 3 minutes with 15 ml of the solution for 6 days (18 times. On the 7th day enamel discs were taken out from the partial denture. Three kinds of measurements were done: enamel permeability testing, depth lesion testing and fluoride retention testing. New demineralized enamel discs were attached to the partial dentures and the volunteers were asked to start rinsing with other solutions using the same protocols. The purpose of this study was to answer the question why the calcifying solutions were no more used as a remineralizing solution. The data ws analyzed using SPSS/PC for two factors Anova and one way Anova for enamel permeability and Kruskal Wallis for studying enamel depth lesion and fluoride retention. There was no significant difference after rinsing with calcifying solution and placebo in enamel permeability, depth lesions, and fluoride retention when compared to fluoride solution. To get a better result in remineralizing carious teeth fluoride contents in solution must be higher than 50 ppm F-.

  5. Orbital atherectomy for the treatment of severely calcified coronary lesions: evidence, technique, and best practices.

    Science.gov (United States)

    Shlofmitz, Evan; Martinsen, Brad J; Lee, Michael; Rao, Sunil V; Généreux, Philippe; Higgins, Joe; Chambers, Jeffrey W; Kirtane, Ajay J; Brilakis, Emmanouil S; Kandzari, David E; Sharma, Samin K; Shlofmitz, Richard

    2017-11-01

    The presence of severe coronary artery calcification is associated with higher rates of angiographic complications during percutaneous coronary intervention (PCI), as well as higher major adverse cardiac events compared with non-calcified lesions. Incorporating orbital atherectomy (OAS) for effective preparation of severely calcified lesions can help maximize the benefits of PCI by attaining maximal luminal gain (or stent expansion) and improve long-term outcomes (by reducing need for revascularization). Areas covered: In this manuscript, the prevalence, risk factors, and impact of coronary artery calcification on PCI are reviewed. Based on current data and experience, the authors review orbital atherectomy technique and best practices to optimize lesion preparation. Expert Commentary: The coronary OAS is the only device approved for use in the U.S. as a treatment for de novo, severely calcified coronary lesions to facilitate stent delivery. Advantages of the device include its ease of use and a mechanism of action that treats bi-directionally, allowing for continuous blood flow during treatment, minimizing heat damage, slow flow, and subsequent need for revascularization. The OAS technique tips reviewed in this article will help inform interventional cardiologists treating patients with severely calcified lesions.

  6. Orbital atherectomy as an adjunct to debulk difficult calcified lesions prior to mesenteric artery stenting.

    Science.gov (United States)

    Manunga, Jesse M; Oderich, Gustavo S

    2012-08-01

    To describe a technique in which percutaneous orbital atherectomy is used to debulk heavily calcified superior mesenteric artery (SMA) occlusions as an adjunct in patients undergoing angioplasty and stenting. The technique is demonstrated in a 62-year-old woman with a replaced right hepatic artery originating from an SMA occluded by densely calcified lesions. Via a left transbrachial approach, a 7-F MPA guide catheter was used to engage the ostium of the SMA, which was crossed using a catheter and guidewire. The calcified lesion was debulked using the 2-mm Diamondback 360° orbital atherectomy system. The wire was exchanged for a 0.014-inch filter wire and 0.018-inch guidewire. Using a 2-guidewire technique, the SMA was stented with a self-expanding stent for the distal lesion that crossed side branches and a balloon-expandable stent at the ostium. A 0.014-inch guidewire was placed into the replaced hepatic artery through a cell of the self-expanding stent, followed by deployment of a small balloon-expandable stent to address the residual lesion. The use of orbital atherectomy to debulk occluded and heavily calcified SMA lesions may optimize the technical results with angioplasty and stenting.

  7. Calcifying epithelial odontogenic tumor, a rare presentation in children: Two case reports

    Directory of Open Access Journals (Sweden)

    Susant Mohanty

    2014-01-01

    Full Text Available Calcifying epithelial odontogenic tumor (CEOT is a rare and benign odontogenic neoplasm that affects the jaws. It is certainly an atypical instance to find this tumor in children. Here, we present two case reports of CEOT presenting in mandible of a 12- and 13-year-old female child, respectively. CEOT have been reported to show features of malignant transformation also.

  8. Computed tomographic diagnosis of calcified inferior vena cava thrombus in a child with Wilm's tumor

    Energy Technology Data Exchange (ETDEWEB)

    Kirks, D R; Ponzi, J W; Korobkin, M

    1980-01-01

    A calcified thrombus in the inferior vena cava of infants and children may be imaged by computed tomography. The precise location of the calcification within the inferior vena cava may be confirmed by computed tomographic scanning during injection of intravenous contrast material.

  9. Calcified Mass on Brain CT in a Teenager with Refractory Seizures.

    Science.gov (United States)

    Khalatbari, Mahmoud Reza; Brunetti, Enrico; Shobeiri, Elham; Moharamzad, Yashar

    2014-12-01

    Cerebral echinococcosis is very rare, representing 2% of all cystic echinococcosis (CE) cases. Primary echinococcal cysts of the brain are extremely rare in pediatric patients. We report on a 16-year-old boy referred to our tertiary center with intractable epilepsy for the previous three years despite receiving full doses of three antiepileptic medications. Brain computed tomography (CT) showed a left frontal calcified mass. Magnetic resonance imaging (MRI) of the brain revealed a well-defined spherical mass in the left frontal lobe, slightly hypointense on T1-weighted and heterogeneous hyperintense on T2-weighted images with no contrast enhancement. With a broad differential list in mind, a surgical intervention was planned. During surgery, a primary calcified cerebral echinococcal cyst with severe adhesion to the adjacent dura of the frontal region was discovered and removed intact. Histopathology examination confirmed the diagnosis. Only phenobarbital was continued and no medical therapy for CE was administered. Two years after surgery, the patient remained free of seizures. In areas endemic for CE, cerebral echinococcal cyst should be included in the differential list of patients with intractable seizures. Though rare, this entity can present itself as a calcified mass on neuroimaging. Surgical removal of the calcified cyst is necessary for control and treatment of the epilepsy.

  10. CT and MRI findings of calcified spinal meningiomas: correlation with pathological findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Won; Kim, Hak Jin [Pusan National University Hospital, Department of Radiology, Busan (Korea); Pusan National University School of Medicine, Medical Research Institute, Busan (Korea); Lee, In Sook [Pusan National University Hospital, Department of Radiology, Busan (Korea); Pusan National University School of Medicine, Medical Research Institute, Busan (Korea); Pusan National University School of Medicine, Department of Radiology, Busan (Korea); Choi, Kyung-Un [Pusan National University School of Medicine, Medical Research Institute, Busan (Korea); Pusan National University Hospital, Department of Pathology, Busan (Korea); Lee, Young Hwan [Catholic University of Daegu School of Medicine, Department of Radiology, Daegu (Korea); Yi, Jae Hyuck [Kyungpook National University Hospital, Department of Radiology, Daegu (Korea); Song, Jong Woon [Inje University Pusan Paik Hospital, Department of Radiology, Busan (Korea); Suh, Kyung Jin [Dongguk University Gyungju Hospital, College of Medicine, Dongguk University, Department of Radiology, Gyungju (Korea)

    2010-04-15

    This study was designed to present characteristic CT and MR findings of calcified spinal meningiomas that correlate with pathological findings and to assess the efficacy of CT for the detection of calcifications within a mass in comparison to MRI. Between 1998 and 2009, 10 out of 11 patients who had pathologically confirmed psammomatous meningiomas showed gross calcifications on CT images and were included in this study. On CT scans of the 10 patients, the distribution pattern, morphology and number of calcifications within masses were evaluated. MRI was performed in seven patients and signal intensities of masses were assessed. The pathological results analyzed semi-quantitatively were compared with the density or the size of calcifications within a mass as seen on a CT scan. Seven of 10 masses were located at the thoracic spine level. Eight masses had intradural locations. The other two masses had extradural locations. Four masses were completely calcified based on standard radiographs and CT. Symptoms duration, the size of the mass and size or number of calcifications within a mass had no correlation. The location, size, and distribution pattern of calcifications within masses were variable. On MR images, signal intensity of calcified tumor varied on all imaging sequences. All the masses enhanced after injection of intravenous contrast material. A calcified meningioma should be first suggested when extradural or intradural masses located in the spine contain calcifications regardless of the size or pattern as depicted on CT, especially in the presence of enhancement as seen on MR images. (orig.)

  11. Outcomes After Orbital Atherectomy of Severely Calcified Left Main Lesions: Analysis of the ORBIT II Study.

    Science.gov (United States)

    Lee, Michael S; Shlofmitz, Evan; Shlofmitz, Richard; Sahni, Sheila; Martinsen, Brad; Chambers, Jeffrey

    2016-09-01

    The ORBIT II trial reported excellent outcomes in patients with severely calcified coronary lesions treated with orbital atherectomy. Severe calcification of the left main (LM) artery represents a complex coronary lesion subset. This study evaluated the safety and efficacy of coronary orbital atherectomy to prepare severely calcified protected LM artery lesions for stent placement. The ORBIT II trial was a prospective, multicenter clinical trial that enrolled 443 patients with severely calcified coronary lesions in the United States. The major adverse cardiac event (MACE) rate through 2 years post procedure, defined by cardiac death, myocardial infarction (CK-MB >3x upper limit of normal with or without a new pathologic Q-wave) and target-vessel revascularization, was compared in the LM and non-left main (NLM) groups. Among the 443 patients, a total of 10 underwent orbital atherectomy of protected LM artery lesions. At 2 years, there was no significant difference in the 2-year MACE rate in the LM and NLM groups (30.0% vs 19.1%, respectively; P=.36). Cardiac death was low in both groups (0% vs 4.4%, respectively; P=.99). Myocardial infarction occurred within 30 days in both groups (10.0% vs 9.7%, respectively; P=.99). Severe dissection, perforation, persistent slow flow, and persistent no reflow did not occur in the LM group. Abrupt closure occurred in 1 patient in the LM group. Orbital atherectomy for patients with heavily calcified LM coronary artery lesions is safe and feasible. Further studies are needed to assess the safety and efficacy of orbital atherectomy in patients with severely calcified LM artery lesions.

  12. In vitro assessment of the composition and microhardness of hard tissues of oral cavity submitted to gamma irradiation; Avaliacao in vitro da composicao e microdureza dos tecidos duros da cavidade bucal submetidos a irradiacao gama

    Energy Technology Data Exchange (ETDEWEB)

    Paredes, Wilber Edison Bernaola

    2017-11-01

    Clinical Radiotherapy is extremely important for the treatment of malignant lesions of the head and neck region, however, exposure to ionizing radiation can lead to systemic or local complications during and after radiation treatment. Among these immediate local complications are the oral cavity xerostomia and the consequent oral mucositis. Regarding late complications produced by radiation, tooth decay of radiation and osteoradionecrosis are included, which are considered dose-dependent lesions, with high incidence in recent decades and difficult to manage, although these appear after completion of treatment and under the influence of local factors. The methodology proposed in this study consists in evaluating the effect of gamma radiation after irradiation of the samples, using the dose used in patients suffering with head and neck cancer. The samples were obtained from human enamel and root dentin; and swine mandibular bone, which were previously polished, and then submitted to the analysis of the initial surface microhardness of all groups. Subsequently, the samples were irradiated in a dose rate of 4 Gy per day, completing a total dose of 72 Gy. Finally, the samples were submitted to surface microhardness analysis after irradiation, which presented statistically significant results from the Student t, ANOVA and Tukey statistical tests referred to the difference of the mean of the initial and final values of each study group with a significant value of p = 0.00 (<0.05). Regarding the morphological analysis in scanning electron microscopy (SEM), the deleterious effect of gamma irradiation was evidenced as structural cracks, breaks and superficial fractures of the analyzed tissues and the biochemical analysis by Attenuated Total Reflection technique using Fourier transform infrared spectroscopy (ATR - FTIR) showed degradation of inorganic components and denaturation of organic compounds; whereby, the effect of gamma irradiation on the hard tissues of the oral

  13. Case report - calcification of the medial collateral ligament of the knee with simultaneous calcifying tendinitis of the rotator cuff.

    Science.gov (United States)

    Kamawal, Yama; Steinert, Andre F; Holzapfel, Boris M; Rudert, Maximilian; Barthel, Thomas

    2016-07-13

    Calcification of the medial collateral ligament (MCL) of the knee is a very rare disease. We report on a case of a patient with a calcifying lesion within the MCL and simultaneous calcifying tendinitis of the rotator cuff in both shoulders. Calcification of the MCL was diagnosed both via x-ray and magnetic resonance imaging (MRI) and was successfully treated surgically. Calcifying tendinitis of the rotator cuff was successfully treated applying conservative methods. This is the first case report of a patient suffering from both a calcifying lesion within the medial collateral ligament and calcifying tendinitis of the rotator cuff in both shoulders. Clinical symptoms, radio-morphological characteristics and macroscopic features were very similar and therefore it can be postulated that the underlying pathophysiology is the same in both diseases. Our experience suggests that magnetic resonance imaging and x-ray are invaluable tools for the diagnosis of this inflammatory calcifying disease of the ligament, and that surgical repair provides a good outcome if conservative treatment fails. It seems that calcification of the MCL is more likely to require surgery than calcifying tendinitis of the rotator cuff. However, the exact reason for this remains unclear to date.

  14. The Role of Inorganic Polyphosphates in the Formation of Bioengineered Cartilage Incorporating a Zone of Calcified Cartilage In Vitro

    Science.gov (United States)

    St-Pierre, Jean-Philippe

    The development of bioengineered cartilage for replacement of damaged articular cartilage has gained momentum in recent years. One such approach has been developed in the Kandel lab, whereby cartilage is formed by seeding primary articular chondrocytes on the top surface of a porous biodegradable calcium polyphosphate (CPP) bone substitute, permitting anchorage of the tissue within the pores of the substrate; however, the interfacial shear properties of the tissue-substrate interface of these biphasic constructs are 1 to 2 orders of magnitude lower than the native cartilage-subchondral bone interface. To overcome this limitation, a strategy was devised to generate a zone of calcified cartilage (ZCC), thereby mimicking the native architecture of the osteochondral junction; however, the ZCC was located slightly above the cartilage-CPP interface. Thus, it was hypothesized that polyphosphate released from the CPP substrate and accumulating in the tissue inhibits the formation of the ZCC at the tissue-substrate interface. Based on this information, a strategy was devised to generate biphasic constructs incorporating a properly located ZCC. This approach involved the application of a thin calcium phosphate film to the surfaces of porous CPP via a sol-gel procedure, thereby limiting the accumulation of polyphosphate in the cartilaginous tissue. This modification to the substrate surface did not negatively impact the quality of the in vitro-formed cartilage tissue or the ZCC. Interfacial shear testing of biphasic constructs demonstrated significantly improved interfacial shear properties in the presence of a properly located ZCC. These studies also led to the observation that chondrocytes produce endogenous polyphosphate and that its levels in deep zone cartilage appear inversely related to mineral deposition within the tissue. Using an in vitro model of cartilage calcification, it was demonstrated that polyphosphate levels are modulated in part by the inhibitory effects

  15. Preferential soft-tissue preservation in the Hot Creek carbonate spring deposit, British Columbia, Canada

    Science.gov (United States)

    Rainey, Dustin K.; Jones, Brian

    2010-05-01

    The relict Holocene Hot Creek carbonate spring deposit in southeast British Columbia is characterized by excellent preservation of soft-tissue organisms (e.g. cyanobacteria), but poor preservation of organisms with hard-tissue (e.g. wood, diatoms). The deposit is formed mainly of calcified cyanobacteria, with fewer mineralized macrophytes (plants), bryophytes (mosses), wood, and diatoms. Cyanobacteria grew as solitary filaments ( Lyngbya) and as radiating hemispherical colonies ( Rivularia). Both were preserved by encrustation and encapsulation while alive, and as casts after filament death and decay. Sheath impregnation was rare to absent. Filament encrustation, whereby calcite crystals nucleated on, and grew away from the sheath exterior, produced moulds that replicated external filament morphology, but hastened filament decay. Filament encapsulation, whereby calcite nucleated in the vicinity of, and grew towards the encapsulated filament, promoted sheath preservation even after trichome decay. Subsequent calcite precipitation inside the hollow sheath generated sheath casts. The inability of mineralizing spring water to penetrate durable cell walls meant that bryophytes, macrophytes, and most wood was preserved by encrustation. Some wood resisted complete decay for several thousand years, and its lignified cell walls allowed rare permineralizations. Diatoms were not preserved in the relict deposit because the frustules were dissolved by the basic spring water. Amorphous calcium carbonate produced by photosynthetic CO 2 removal may have acted as nucleation sites for physicochemically precipitated calcite. Thus, metabolic activities of floral organisms probably initiated biotic mineralization, but continuous inorganic calcite precipitation on and in flora ensured that soft tissues were preserved.

  16. Differential responses of calcifying and non-calcifying epibionts of a brown macroalga to present-day and future upwelling pCO2.

    Directory of Open Access Journals (Sweden)

    Vincent Saderne

    Full Text Available Seaweeds are key species of the Baltic Sea benthic ecosystems. They are the substratum of numerous fouling epibionts like bryozoans and tubeworms. Several of these epibionts bear calcified structures and could be impacted by the high pCO2 events of the late summer upwellings in the Baltic nearshores. Those events are expected to increase in strength and duration with global change and ocean acidification. If calcifying epibionts are impacted by transient acidification as driven by upwelling events, their increasing prevalence could cause a shift of the fouling communities toward fleshy species. The aim of the present study was to test the sensitivity of selected seaweed macrofoulers to transient elevation of pCO2 in their natural microenvironment, i.e. the boundary layer covering the thallus surface of brown seaweeds. Fragments of the macroalga Fucus serratus bearing an epibiotic community composed of the calcifiers Spirorbis spirorbis (Annelida and Electra pilosa (Bryozoa and the non-calcifier Alcyonidium hirsutum (Bryozoa were maintained for 30 days under three pCO2 conditions: natural 460 ± 59 µatm, present-day upwelling1193 ± 166 µatm and future upwelling 3150 ± 446 µatm. Only the highest pCO2 caused a significant reduction of growth rates and settlement of S. spirorbis individuals. Additionally, S. spirorbis settled juveniles exhibited enhanced calcification of 40% during daylight hours compared to dark hours, possibly reflecting a day-night alternation of an acidification-modulating effect by algal photosynthesis as opposed to an acidification-enhancing effect of algal respiration. E. pilosa colonies showed significantly increased growth rates at intermediate pCO2 (1193 µatm but no response to higher pCO2. No effect of acidification on A. hirsutum colonies growth rates was observed. The results suggest a remarkable resistance of the algal macro-epibionts to levels of acidification occurring at present day upwellings in the Baltic

  17. Chemical and physical analysis on hard tissues after irradiation with short pulse Nd:YAG laser; Alteracoes quimicas e fisicas de tecidos duros irradiados por laser de neodimio chaveado

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Andrea Antunes

    2003-07-01

    This work reports on a study that was designed to investigate chemical, physical and morphological alterations in the dental enamel surface. The influence of application of laser in enamel surface by microscopic technical, X-ray fluorescence for chemical analysis, physical property as well as hardness and thermal analysis with Nd:YAG laser is also pointed out. A prototype of Nd:YAG (Q-switched) laser developed at the Center of Lasers and Applications - Institute of Energetic and Nuclear Research, aiming applications in the Medical Sciences that typical wavelength of 1.064 nm was used. The modifications in human dental enamel chemical composition for major and trace elements are here outlined. The accuracy of procedures was performed by analysis of natural hydroxyapatite as standard reference material. The identification and quantification of the chemical elements presented in the dental tissue samples were performed trough EDS, XRF and INAA. We determined the rate Calcium/Phosphorus (Ca/P) for different techniques. We performed an analysis in different regions of the surface and for different areas allowing a description of the chemical change in the total area of the specimen and the assessment of the compositional homogeneity of the each specimen. A comparison between XRF and INAA is presented. Based on morphological analysis of the irradiated surfaces with short pulse Nd:YAG laser we determined the area surrounded by the irradiation for the parameters for this thesis, and this technique allowed us to visualize the regions of fusion and re-solidification. The energy densities ranged from 10 J/cm{sup 2} to 40 J/cm{sup 2}, with pulse width of 6, 10 e 200 ns, and repetition rates of 5 and 7 Hz. In this thesis, FTIR-spectroscopy is used to analyze powder of mineralized tissue as well as enamel, dentine, root and cementum for human and bovine teeth after irradiation with short-pulse Nd:YAG laser. Characteristic spectra were obtained for the proteins components and

  18. Aggressive plaque modification with rotational atherectomy and cutting balloon for optimal stent expansion in calcified lesions

    Science.gov (United States)

    Tang, Zhe; Bai, Jing; Su, Shao-Ping; Lee, Pui-Wai; Peng, Liang; Zhang, Tao; Sun, Ting; Nong, Jing-Guo; Li, Tian-De; Wang, Yu

    2016-01-01

    Objective To evaluate the factors affecting optimal stent expansion in calcified lesions treated by aggressive plaque modification with rotational atherectomy (RA) and a cutting balloon (CB). Methods From January 2014 to May 2015, 92 patients with moderate to severe coronary calcified lesions underwent rotational atherectomy and intravascular ultrasound imaging at Chinese PLA General Hospital (Beijing, China) were included in this study. They were divided into a rotational artherectomy combined with cutting balloon (RACB) group (46 patients treated with RA followed by CB angioplasty) and an RA group (46 patients treated with RA followed by plain balloon angioplasty). Another 40 patients with similar severity of their calcified lesions treated with plain old balloon angioplasty (POBA) were demographically matched to the other groups and defined as the POBA group. All patients received a drug-eluting stent after plaque preparation. Lumen diameter and lumen diameter stenosis (LDS) were measured by quantitative coronary angiography at baseline, after RA, after dilatation, and after stenting. Optimal stent expansion was defined as the final LDS < 10%. Results The initial and post-RA LDS values were similar among the three groups. However, after dilatation, the LDS significantly decreased in the RACB group (from 54.5% ± 8.9% to 36.1% ± 7.1%) but only moderately decreased (from 55.7% ± 7.8% to 46.9% ± 9.4%) in the RA group (time × group, P < 0.001). After stenting, there was a higher rate of optimal stent expansion in the RACB group (71.7% in the RACB group, 54.5% in the RA group, and 15% in the POBA group, P < 0.001), and the final LDS was significantly diminished in the RACB group compared to the other two groups (6.0% ± 2.3%, 10.8% ± 3.3%, 12.7% ± 2.1%, P < 0.001). Moreover, an LDS ≤ 40% after plaque preparation (OR = 2.994, 95% CI: 1.297–6.911) was associated with optimal stent expansion, which also had a positive correlation with the appearance of a

  19. 10-year follow-up of calcifying odontogenic cyst in the periapical region of vital maxillary central incisor.

    Science.gov (United States)

    de Carvalhosa, Artur Aburad; de Araújo Estrela, Cyntia Rodrigues; Borges, Alvaro Henrique; Guedes, Orlando Aguirre; Estrela, Carlos

    2014-10-01

    Radiographic images may lead to misinterpretations of lesions of endodontic and nonendodontic origin. This report describes a case of a 10-year follow-up of a calcifying odontogenic cyst (COC) in the periapical region of a vital maxillary central incisor in a 9-year-old boy. The patient revealed a history of a swelling in the periapical area of tooth #9. The patient denied any dental trauma or history of pain. Clinical examination revealed no mobility, but there was discrete discomfort when horizontal pressure was applied. Pulp vitality was present in all maxillary anterior teeth. Radiographs revealed an oval radiolucent lesion in the periapical region of maxillary central incisor. The therapeutic option was enucleation of the periapical lesion and histologic examination of the specimen. Microscopic findings suggested the diagnosis of a COC. At a follow-up visit 10 years after surgery, panoramic and periapical radiographs showed new bone formation; the patient did not have any pain, and pulp vitality was maintained in all teeth in this area. A COC should be part of the differential diagnosis of other jaw lesions, such as apical periodontitis. The definitive diagnosis of a COC can only be made after microscopic evaluation of the specimen. The follow-up is a helpful reference because it confirms the survival of pulp tissue and no recurrence of the COC. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  20. Effect of exercise on thicknesses of mature hyaline cartilage, calcified cartilage, and subchondral bone of equine tarsi.

    Science.gov (United States)

    Tranquille, Carolyne A; Blunden, Antony S; Dyson, Sue J; Parkin, Tim D H; Goodship, Allen E; Murray, Rachel C

    2009-12-01

    OBJECTIVE-To investigate effects of exercise on hyaline cartilage (HC), calcified cartilage (CC), and subchondral bone (SCB) thickness patterns of equine tarsi. SAMPLE POPULATION-30 tarsi from cadavers of horses with known exercise history. PROCEDURES-Tarsi were assigned to 3 groups according to known exercise history as follows: pasture exercise only (PE tarsi), low-intensity general-purpose riding exercise (LE tarsi), and high-intensity elite competition riding exercise (EE tarsi). Osteochondral tissue from distal tarsal joints underwent histologic preparation. Hyaline cartilage, CC, and SCB thickness were measured at standard sites at medial, midline, and lateral locations across joints with a histomorphometric technique. RESULTS-HC, CC, and SCB thickness were significantly greater at all sites in EE tarsi, compared with PE tarsi; this was also true when LE tarsi were compared with PE tarsi. At specific sites, HC, CC, and SCB were significantly thicker in EE tarsi, compared with LE tarsi. Along the articular surface of the proximal aspect of the third metatarsal bone, SCB was thickest in EE tarsi and thinnest in LE tarsi; increases were greatest at sites previously reported to undergo peak strains and osteochondral damage. CONCLUSIONS AND CLINICAL RELEVANCE-Increased exercise was associated with increased HC, CC, and SCB thickness in mature horses. At sites that undergo high compressive strains, with a reported predisposition to osteoarthritic change, there was increased CC and SCB thickness. These results may provide insight into the interaction between adaptive response to exercise and pathological change.

  1. A pigmented calcifying cystic odontogenic tumor associated with compound odontoma: a case report and review of literature

    Directory of Open Access Journals (Sweden)

    Borkosky Silvia S

    2007-09-01

    Full Text Available Abstract Background Pigmented intraosseous odontogenic lesions are rare with only 47 reported cases in the English literature. Among them, pigmented calcifying cystic odontogenic tumor, formerly known as calcifying odontogenic cyst, is the most common lesion with 20 reported cases. Methods A case of pigmented calcifying cystic odontogenic tumor associated with odontoma occurring at the mandibular canine-premolar region of a young Japanese boy is presented with radiographic, and histological findings. Special staining, electron microscopic study and immunohistochemical staining were also done to characterize the pigmentation. Results The pigments in the lesion were confirmed to be melanin by Masson-Fontana staining and by transmission electron microscopy. The presence of dendritic melanocytes within the lesion was also demonstrated by S-100 immunostaining. Conclusion The present case report of pigmented calcifying cystic odontogenic tumor associated with odontoma features a comprehensive study on melanin and melanocytes, including histochemical, immunohistochemical and transmission electron microscopic findings.

  2. Directional atherectomy of a heavy calcified axillary artery stenosis inducing critical hand ischemia.

    Science.gov (United States)

    Anzuini, Angelo; Palloshi, Altin; Aprigliano, Gianfranco; Ielasi, Alfonso

    2013-07-01

    The presence of a severe calcified peripheral artery lesion is responsible for a poor response to balloon dilation, due to significant acute vessel recoil and frequent flow-limiting dissections requiring stent implantation. This possibility could be associated with very high compression and/or fracture rates particularly in cases of lesion located at the mobile joints. In this setting directional atherectomy offers the theoretical advantages of eliminating stretch injury on arterial walls and reducing the restenosis rate by direct plaque excision. In this report, we present a case of critical hand ischemia due to a heavily calcified axillary artery lesion managed by directional atherectomy and balloon angioplasty followed by immediate angiographic success and sustained clinical benefit up to 3 years of follow-up.

  3. Successful Use of Orbital Atherectomy as an Adjunct in Treating Extensively Calcified Mesenteric Artery Lesions.

    Science.gov (United States)

    Richard, Michele; Krol, Emilia; Dietzek, Alan

    2016-10-01

    To describe the use of orbital technique of atherectomy as an adjunct to successful angioplasty and stent placement of the superior mesenteric artery (SMA). The technique is demonstrated in a 68-year-old man with critical SMA stenosis. The SMA was cannulated with 0.014-in wire, but the lesion was highly stenotic and densely calcified and prevented the passage of even the smallest 1.5-mm balloon. Orbital atherectomy was thus performed with a 1.25-mm CSI crown. Balloon angioplasty was then possible with a 4 mm × 2 cm balloon followed by placement of a 7 mm × 22 mm balloon-mounted stent. The use of atherectomy as an adjunct to angioplasty and stenting in extensive, calcified SMA lesions supports the value of this technique to avoid a much larger and morbid open procedure. Published by Elsevier Inc.

  4. Primary breast osteosarcoma mimicking calcified fibroadenoma on screening digital breast tomosynthesis mammogram

    Directory of Open Access Journals (Sweden)

    Debbie Lee Bennett, MD

    2017-12-01

    Full Text Available Primary breast osteosarcoma is a rare malignancy, with mostly case reports in the literature. The appearance of breast osteosarcoma on digital breast tomosynthesis imaging has not yet been described. A 69-year-old woman presents for routine screening mammography and is found to have a calcified mass in her right breast. Pattern of calcification appeared “sunburst” on digital breast tomosynthesis images. This mass was larger than on the previous year's mammogram, at which time it had been interpreted as a benign calcified fibroadenoma. The subsequent workup demonstrated the mass to reflect primary breast osteosarcoma. The patient's workup and treatment are detailed in this case. Primary breast osteosarcoma, although rare, should be included as a diagnostic consideration for breast masses with a sunburst pattern of calcifications, particularly when the mammographic appearance has changed.

  5. A universal carbonate ion effect on stable oxygen isotope ratios in unicellular planktonic calcifying organisms

    OpenAIRE

    Ziveri, P.; Thoms, S.; Probert, I.; Geisen, M.; Langer, H.

    2012-01-01

    The oxygen isotopic composition (δ18O) of calcium carbonate of planktonic calcifying organisms is a key tool for reconstructing both past seawater temperature and salinity. The calibration of paloeceanographic proxies relies in general on empirical relationships derived from field experiments on extant species. Laboratory experiments have more often than not revealed that variables other than the target parameter influence the proxy signal, which makes proxy c...

  6. Cardiac Calcified Amorphous Tumor of the Mitral Valve Presenting as Transient Ischemic Attack.

    Science.gov (United States)

    Abbasi Teshnizi, Mohammad; Ghorbanzadeh, Atefeh; Zirak, Nahid; Manafi, Babak; Moeinipour, Aliasghar

    2017-01-01

    Cardiac calcified amorphous tumors (CATs) are an extremely rare nonneoplastic intracardiac masses. They have been reported in the literature in only a few cases. Thus, the incidence, pathogenesis, and best approach to the treatment are not certain. We report a case of CATs on the atrial surface of the anterior mitral valve leaflet in a 37-year-old female who was diagnosed by histopathological examination after surgical removal.

  7. Cardiac Calcified Amorphous Tumor of the Mitral Valve Presenting as Transient Ischemic Attack

    Directory of Open Access Journals (Sweden)

    Mohammad Abbasi Teshnizi

    2017-01-01

    Full Text Available Cardiac calcified amorphous tumors (CATs are an extremely rare nonneoplastic intracardiac masses. They have been reported in the literature in only a few cases. Thus, the incidence, pathogenesis, and best approach to the treatment are not certain. We report a case of CATs on the atrial surface of the anterior mitral valve leaflet in a 37-year-old female who was diagnosed by histopathological examination after surgical removal.

  8. Calcified subdural haematomas associated with arrested hydrocephalus - late sequelae of shunt operation in infancy

    Energy Technology Data Exchange (ETDEWEB)

    Barmeir, E.P.; Stern, D.; Harel, S.; Holtzman M.; Krije, T.J.

    1985-08-01

    Calcified chronic subdural haematoms (SDH) and features of arrested (compensated) hydrocephalus were demonstrated by skull radiography and cranial computed tomography (CT) in two children who had no neurological deficit. Ventricular surgical drainage had been performed 8 and 11 years prior to admission and the haematomas remained subsequently undetected. The following presentation will serve to illustrate the characteristic radiological features of this entity, the issue of management, and includes a review of the literature.

  9. Predominance of heavily calcified coccolithophores at low CaCO3 saturation during winter in the Bay of Biscay

    OpenAIRE

    Smith, Helen E. K.; Tyrrell, Toby; Charalampopoulou, Anastasia; Dumousseaud, Cynthia; Legge, Oliver J.; Birchenough, Sarah; Pettit, Laura R.; Garley, Rebecca; Hartman, Sue E.; Hartman, Mark C.; Sagoo, Navjit; Daniels, Chris J.; Achterberg, Eric P.; Hydes, David J.

    2012-01-01

    Coccolithophores are an important component of the Earth system, and, as calcifiers, their possible susceptibility to ocean acidification is of major concern. Laboratory studies at enhanced pCO2 levels have produced divergent results without overall consensus. However, it has been predicted from these studies that, although calcification may not be depressed in all species, acidification will produce “a transition in dominance from more to less heavily calcified coccolithophores” [Ridgwell A,...

  10. Rapid mass movement of chloroplasts during segment formation of the calcifying siphonalean green alga, Halimeda macroloba

    DEFF Research Database (Denmark)

    Larkum, Anthony W D; Salih, Anya; Kühl, Michael

    2011-01-01

    The calcifying siphonalean green alga, Halimeda macroloba is abundant on coral reefs and is important in the production of calcium carbonate sediments. The process by which new green segments are formed over-night is revealed here for the first time.......The calcifying siphonalean green alga, Halimeda macroloba is abundant on coral reefs and is important in the production of calcium carbonate sediments. The process by which new green segments are formed over-night is revealed here for the first time....

  11. Clinical implications of calcifying nanoparticles in dental diseases: a critical review

    Directory of Open Access Journals (Sweden)

    Alenazy MS

    2013-12-01

    Full Text Available Mohammed S Alenazy,1 Hezekiah A Mosadomi2,3 1Restorative Dentistry Department, 2Oral and Maxillofacial Pathology Department, 3Research Center, Riyadh Colleges of Dentistry and Pharmacy, Riyadh, Saudi Arabia Background: Unknown cell-culture contaminants were described by Kajander and Ciftçioğlu in 1998. These contaminants were called nanobacteria initially and later calcifying nanoparticles (CNPs. Their exact nature is unclear and controversial. CNPs have unique and unusual characteristics, which preclude placing them into any established evolutionary branch of life. Aim: The aim of this systematic review was to assess published data concerning CNPs since 1998 in general and in relation to dental diseases in particular. Materials and methods: The National Library of Medicine (PubMed and Society of Photographic Instrumentation Engineers (SPIE electronic and manual searches were conducted. Nanobacteria and calcifying nanoparticles were used as keywords. The search yielded 135 full-length papers. Further screening of the titles and abstracts that followed the review criteria resulted in 43 papers that met the study aim. Conclusion: The review showed that the existence of nanobacteria is still controversial. Some investigators have described a possible involvement of CNPs in pulpal and salivary gland calcifications, as well as the possible therapeutic use of CNPs in the treatment of cracked and/or eroded teeth. Keywords: calcifying nanoparticles, nanobacteria, sialolith, pulp stone, enamel repair

  12. Pacific-wide contrast highlights resistance of reef calcifiers to ocean acidification.

    Science.gov (United States)

    Comeau, S; Carpenter, R C; Nojiri, Y; Putnam, H M; Sakai, K; Edmunds, P J

    2014-09-07

    Ocean acidification (OA) and its associated decline in calcium carbonate saturation states is one of the major threats that tropical coral reefs face this century. Previous studies of the effect of OA on coral reef calcifiers have described a wide variety of outcomes for studies using comparable partial pressure of CO2 (pCO2) ranges, suggesting that key questions remain unresolved. One unresolved hypothesis posits that heterogeneity in the response of reef calcifiers to high pCO2 is a result of regional-scale variation in the responses to OA. To test this hypothesis, we incubated two coral taxa (Pocillopora damicornis and massive Porites) and two calcified algae (Porolithon onkodes and Halimeda macroloba) under 400, 700 and 1000 μatm pCO2 levels in experiments in Moorea (French Polynesia), Hawaii (USA) and Okinawa (Japan), where environmental conditions differ. Both corals and H. macroloba were insensitive to OA at all three locations, while the effects of OA on P. onkodes were location-specific. In Moorea and Hawaii, calcification of P. onkodes was depressed by high pCO2, but for specimens in Okinawa, there was no effect of OA. Using a study of large geographical scale, we show that resistance to OA of some reef species is a constitutive character expressed across the Pacific. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  13. δ11B as monitor of calcification site pH in divergent marine calcifying organisms

    Science.gov (United States)

    Sutton, Jill N.; Liu, Yi-Wei; Ries, Justin B.; Guillermic, Maxence; Ponzevera, Emmanuel; Eagle, Robert A.

    2018-03-01

    The boron isotope composition (δ11B) of marine biogenic carbonates has been predominantly studied as a proxy for monitoring past changes in seawater pH and carbonate chemistry. However, a number of assumptions regarding chemical kinetics and thermodynamic isotope exchange reactions are required to derive seawater pH from δ11B biogenic carbonates. It is also probable that δ11B of biogenic carbonate reflects seawater pH at the organism's site of calcification, which may or may not reflect seawater pH. Here, we report the development of methodology for measuring the δ11B of biogenic carbonate samples at the multi-collector inductively coupled mass spectrometry facility at Ifremer (Plouzané, France) and the evaluation of δ11BCaCO3 in a diverse range of marine calcifying organisms reared for 60 days in isothermal seawater (25 °C) equilibrated with an atmospheric pCO2 of ca. 409 µatm. Average δ11BCaCO3 composition for all species evaluated in this study range from 16.27 to 35.09 ‰, including, in decreasing order, coralline red alga Neogoniolithion sp. (35.89 ± 3.71 ‰), temperate coral Oculina arbuscula (24.12 ± 0.19 ‰), serpulid worm Hydroides crucigera (19.26 ± 0.16 ‰), tropical urchin Eucidaris tribuloides (18.71 ± 0.26 ‰), temperate urchin Arbacia punctulata (16.28 ± 0.86 ‰), and temperate oyster Crassostrea virginica (16.03 ‰). These results are discussed in the context of each species' proposed mechanism of biocalcification and other factors that could influence skeletal and shell δ11B, including calcifying site pH, the proposed direct incorporation of isotopically enriched boric acid (instead of borate) into biogenic calcium carbonate, and differences in shell/skeleton polymorph mineralogy. We conclude that the large inter-species variability in δ11BCaCO3 (ca. 20 ‰) and significant discrepancies between measured δ11BCaCO3 and δ11BCaCO3 expected from established relationships between abiogenic δ11BCaCO3 and seawater pH arise

  14. Comprehensive hard materials

    CERN Document Server

    2014-01-01

    Comprehensive Hard Materials deals with the production, uses and properties of the carbides, nitrides and borides of these metals and those of titanium, as well as tools of ceramics, the superhard boron nitrides and diamond and related compounds. Articles include the technologies of powder production (including their precursor materials), milling, granulation, cold and hot compaction, sintering, hot isostatic pressing, hot-pressing, injection moulding, as well as on the coating technologies for refractory metals, hard metals and hard materials. The characterization, testing, quality assurance and applications are also covered. Comprehensive Hard Materials provides meaningful insights on materials at the leading edge of technology. It aids continued research and development of these materials and as such it is a critical information resource to academics and industry professionals facing the technological challenges of the future. Hard materials operate at the leading edge of technology, and continued res...

  15. Use of Aromatase Inhibitors in Large Cell Calcifying Sertoli Cell Tumors: Effects on Gynecomastia, Growth Velocity, and Bone Age

    Science.gov (United States)

    Crocker, Melissa K.; Gourgari, Evgenia; Stratakis, Constantine A.

    2014-01-01

    Context: Large cell calcifying Sertoli cell tumors (LCCSCT) present in isolation or, especially in children, in association with Carney Complex (CNC) or Peutz-Jeghers Syndrome (PJS). These tumors overexpress aromatase (CYP19A1), which leads to increased conversion of delta-4-androstenedione to estrone and testosterone to estradiol. Prepubertal boys may present with growth acceleration, advanced bone age, and gynecomastia. Objective: To investigate the outcomes of aromatase inhibitor therapy (AIT) in prepubertal boys with LCCSCTs. Design: Case series of a very rare tumor and chart review of cases treated at other institutions. Setting: Tertiary care and referral center. Patients: Six boys, five with PJS and one with CNC, were referred to the National Institutes of Health for treatment of LCCSCT. All patients had gynecomastia, testicular enlargement, and advanced bone ages, and were being treated by their referring physicians with AIT. Interventions: Patients were treated for a total of 6–60 months on AIT. Main Outcome Measures: Height, breast tissue mass, and testicular size were all followed; physical examination, scrotal ultrasounds, and bone ages were obtained, and hormonal concentrations and tumor markers were measured. Results: Tumor markers were negative. All patients had decreases in breast tissue while on therapy. Height percentiles declined, and predicted adult height moved closer to midparental height as bone age advancement slowed. Testicular enlargement stabilized until entry into central puberty. Only one patient required unilateral orchiectomy. Conclusions: Patients with LCCSCT benefit from AIT with reduction and/or elimination of gynecomastia and slowing of linear growth and bone age advancement. Further study of long-term outcomes and safety monitoring are needed but these preliminary data suggest that mammoplasty and/or orchiectomy may be foregone in light of the availability of medical therapy. PMID:25226294

  16. Combined nanoindentation testing and scanning electron microscopy of bone and articular calcified cartilage in an equine fracture predilection site.

    Science.gov (United States)

    Doube, M; Firth, E C; Boyde, A; Bushby, A J

    2010-06-03

    Condylar fracture of the third metacarpal bone (Mc3) is the commonest cause of racetrack fatality in Thoroughbred horses. Linear defects involving hyaline articular cartilage, articular calcified cartilage (ACC) and subchondral bone (SCB) have been associated with the fracture initiation site, which lies in the sagittal grooves of the Mc3 condyle. We discovered areas of thickened and abnormally-mineralised ACC in the sagittal grooves of several normal 18-month-old horses, at the same site that linear defects and condylar fracture occur in older Thoroughbreds and questioned whether this tissue had altered mechanical properties. We embedded bone slices in PMMA, prepared flat surfaces normal to the articular surface and studied ACC and SCB using combined quantitative backscattered electron scanning electron microscopy (qBSE) and nanoindentation testing: this allowed correlation of mineralisation density and tissue stiffness (E) at the micron scale. We studied both normal and affected grooves, and also normal condylar regions. Large arrays of indentations could be visualised as 2-dimensional maps of E with a limit to resolution of indentation spacing, which is much larger than qBSE pixel spacing. ACC was more highly mineralised but less stiff in early linear defects than in control regions, while subchondral bone was more highly mineralised and stiffer in specimens with early linear defects than those without. Thus both ACC and SCB mineralisation may be abnormal in a class of early linear defect in 18-month-old Thoroughbred horses, and this may possibly contribute to later fracture of the Mc3 condyle.

  17. Combined nanoindentation testing and scanning electron microscopy of bone and articular calcified cartilage in an equine fracture predilection site

    Directory of Open Access Journals (Sweden)

    M Doube

    2010-06-01

    Full Text Available Condylar fracture of the third metacarpal bone (Mc3 is the commonest cause of racetrack fatality in Thoroughbred horses. Linear defects involving hyaline articular cartilage, articular calcified cartilage (ACC and subchondral bone (SCB have been associated with the fracture initiation site, which lies in the sagittal grooves of the Mc3 condyle. We discovered areas of thickened and abnormally-mineralised ACC in the sagittal grooves of several normal 18-month-old horses, at the same site that linear defects and condylar fracture occur in older Thoroughbreds and questioned whether this tissue had altered mechanical properties. We embedded bone slices in PMMA, prepared flat surfaces normal to the articular surface and studied ACC and SCB using combined quantitative backscattered electron scanning electron microscopy (qBSE and nanoindentation testing: this allowed correlation of mineralisation density and tissue stiffness (E at the micron scale. We studied both normal and affected grooves, and also normal condylar regions. Large arrays of indentations could be visualised as 2-dimensional maps of E with a limit to resolution of indentation spacing, which is much larger than qBSE pixel spacing. ACC was more highly mineralised but less stiff in early linear defects than in control regions, while subchondral bone was more highly mineralised and stiffer in specimens with early linear defects than those without. Thus both ACC and SCB mineralisation may be abnormal in a class of early linear defect in 18-month-old Thoroughbred horses, and this may possibly contribute to later fracture of the Mc3 condyle.

  18. Induced spherococcoid hard wheat

    International Nuclear Information System (INIS)

    Yanev, Sh.

    1981-01-01

    A mutant has been obtained - a spheroccocoid line -through irradiation of hard wheat seed with fast neutrons. It is distinguished by semispherical glumes and smaller grain; the plants have low stem with erect leaves but with shorter spikes and with lesser number of spikelets than those of the initial cultivar. Good productive tillering and resistance to lodging contributed to 23.5% higher yield. The line was superior to the standard and the initial cultivars by 14.2% as regards protein content, and by up to 22.8% - as to flour gluten. It has been successfully used in hybridization producing high-yielding hard wheat lines resistant to lodging, with good technological and other indicators. The possibility stated is of obtaining a spherococcoid mutant in tetraploid (hard) wheat out of the D-genome as well as its being suited to hard wheat breeding to enhance protein content, resistance to lodging, etc. (author)

  19. Hard probes 2006 Asilomar

    CERN Multimedia

    2006-01-01

    "The second international conference on hard and electromagnetic probes of high-energy nuclear collisions was held June 9 to 16, 2006 at the Asilomar Conference grounds in Pacific Grove, California" (photo and 1/2 page)

  20. Hard coal; Steinkohle

    Energy Technology Data Exchange (ETDEWEB)

    Loo, Kai van de; Sitte, Andreas-Peter [Gesamtverband Steinkohle e.V., Herne (Germany)

    2013-04-01

    The year 2012 benefited from a growth of the consumption of hard coal at the national level as well as at the international level. Worldwide, the hard coal still is the number one energy source for power generation. This leads to an increasing demand for power plant coal. In this year, the conversion of hard coal into electricity also increases in this year. In contrast to this, the demand for coking coal as well as for coke of the steel industry is still declining depending on the market conditions. The enhanced utilization of coal for the domestic power generation is due to the reduction of the nuclear power from a relatively bad year for wind power as well as reduced import prices and low CO{sub 2} prices. Both justify a significant price advantage for coal in comparison to the utilisation of natural gas in power plants. This was mainly due to the price erosion of the inexpensive US coal which partly was replaced by the expansion of shale gas on the domestic market. As a result of this, the inexpensive US coal looked for an outlet for sales in Europe. The domestic hard coal has continued the process of adaptation and phase-out as scheduled. Two further hard coal mines were decommissioned in the year 2012. RAG Aktiengesellschaft (Herne, Federal Republic of Germany) running the hard coal mining in this country begins with the preparations for the activities after the time of mining.

  1. A voltage-gated H+ channel underlying pH homeostasis in calcifying coccolithophores.

    Directory of Open Access Journals (Sweden)

    Alison R Taylor

    2011-06-01

    Full Text Available Marine coccolithophorid phytoplankton are major producers of biogenic calcite, playing a significant role in the global carbon cycle. Predicting the impacts of ocean acidification on coccolithophore calcification has received much recent attention and requires improved knowledge of cellular calcification mechanisms. Uniquely amongst calcifying organisms, coccolithophores produce calcified scales (coccoliths in an intracellular compartment and secrete them to the cell surface, requiring large transcellular ionic fluxes to support calcification. In particular, intracellular calcite precipitation using HCO₃⁻ as the substrate generates equimolar quantities of H+ that must be rapidly removed to prevent cytoplasmic acidification. We have used electrophysiological approaches to identify a plasma membrane voltage-gated H+ conductance in Coccolithus pelagicus ssp braarudii with remarkably similar biophysical and functional properties to those found in metazoans. We show that both C. pelagicus and Emiliania huxleyi possess homologues of metazoan H(v1 H+ channels, which function as voltage-gated H+ channels when expressed in heterologous systems. Homologues of the coccolithophore H+ channels were also identified in a diversity of eukaryotes, suggesting a wide range of cellular roles for the H(v1 class of proteins. Using single cell imaging, we demonstrate that the coccolithophore H+ conductance mediates rapid H+ efflux and plays an important role in pH homeostasis in calcifying cells. The results demonstrate a novel cellular role for voltage gated H+ channels and provide mechanistic insight into biomineralisation by establishing a direct link between pH homeostasis and calcification. As the coccolithophore H+ conductance is dependent on the trans-membrane H+ electrochemical gradient, this mechanism will be directly impacted by, and may underlie adaptation to, ocean acidification. The presence of this H+ efflux pathway suggests that there is no obligate

  2. Preliminary Evaluation of Microbial Communities Isolated from the Calcifying Fluid of Oysters

    Science.gov (United States)

    Banker, R.

    2016-02-01

    The process of biomineralization is defined as the selective uptake of elements that are incorporated into a defined mineral structure under strict biological control. For bivalve molluscs, such as clams, oysters, and mussels, the mantle is the primary organ in control of shell deposition. Alternatively, remote calcification takes place when carbonate-precipitating microbes (e.g. sulfate reducers) colonize a shell-secreting organism and enhance the ability of the host to build shell material. The oyster syndrome is a term that describes bivalves that possess an unusual shell morphology characterized by exceptionally thick valves containing numerous chambers filled with chalky calcite. Although remote calcification via microbial metabolism has been proposed as a mechanism of chalky deposit formation in oysters, this hypothesis has not yet been rigorously investigated. Here I present data on the microbial communities found in the calcifying fluid of two oyster species; Crassostrea gigas and Ostrea lurida are examples of oysters that do and do not exhibit the oyster syndrome, respectively. Comparison of the microbiomes of these two morphological end members may provide insight into the role of microbes in the formation of chalky deposits. Results indicate that the microbial community in the surrounding water is the dominant source for bacterial taxa found in the calcifying fluid of both oyster species. Also, it appears as though C. gigas maintains a microbial community that is more similar to its ambient environment than O. lurida. These results demonstrate that the ambient aquatic environment has a guiding influence on the microbiome found in the calcifying fluid of bivalve molluscs. However, the magnitude of this effect varies among organisms, even those that are closely related.

  3. Effects of Ocean Acidification and Temperature Increases on the Photosynthesis of Tropical Reef Calcified Macroalgae.

    Science.gov (United States)

    Scherner, Fernando; Pereira, Cristiano Macedo; Duarte, Gustavo; Horta, Paulo Antunes; E Castro, Clovis Barreira; Barufi, José Bonomi; Pereira, Sonia Maria Barreto

    2016-01-01

    Climate change is a global phenomenon that is considered an important threat to marine ecosystems. Ocean acidification and increased seawater temperatures are among the consequences of this phenomenon. The comprehension of the effects of these alterations on marine organisms, in particular on calcified macroalgae, is still modest despite its great importance. There are evidences that macroalgae inhabiting highly variable environments are relatively resilient to such changes. Thus, the aim of this study was to evaluate experimentally the effects of CO2-driven ocean acidification and temperature rises on the photosynthesis of calcified macroalgae inhabiting the intertidal region, a highly variable environment. The experiments were performed in a reef mesocosm in a tropical region on the Brazilian coast, using three species of frondose calcifying macroalgae (Halimeda cuneata, Padina gymnospora, and Tricleocarpa cylindrica) and crustose coralline algae. The acidification experiment consisted of three treatments with pH levels below those occurring in the region (-0.3, -0.6, -0.9). For the temperature experiment, three temperature levels above those occurring naturally in the region (+1, +2, +4°C) were determined. The results of the acidification experiment indicate an increase on the optimum quantum yield by T. cylindrica and a decline of this parameter by coralline algae, although both only occurred at the extreme acidification treatment (-0.9). The energy dissipation mechanisms of these algae were also altered at this extreme condition. Significant effects of the temperature experiment were limited to an enhancement of the photosynthetic performance by H. cuneata although only at a modest temperature increase (+1°C). In general, the results indicate a possible photosynthetic adaptation and/or acclimation of the studied macroalgae to the expected future ocean acidification and temperature rises, as separate factors. Such relative resilience may be a result of the

  4. Predictive Factors of Potential Malignant Transformation in Recurrent Calcifying Cystic Odontogenic Tumor: Review of the Literature

    Directory of Open Access Journals (Sweden)

    Sepideh Mokhtari

    2013-01-01

    Full Text Available Calcifying cystic odontogenic tumor (CCOT demonstrates considerable diversity in histopathology and clinical behavior. Ghost cell odontogenic carcinoma (GCOC is the rare malignant counterpart of CCOT and it frequently arises from malignant transformation of a recurrent CCOT. In this paper, we present a case of CCOT and discuss its distinct histopathologic features in recurrence. Then, we will have a review on clinical, histopathological, and immunohistochemical aspects of GCOC in the literature. Predictive factors of malignant transformation in a benign CCOT will also be discussed.

  5. Osteochondral lesions in distal tarsal joints of Icelandic horses reveal strong associations between hyaline and calcified cartilage abnormalities

    Directory of Open Access Journals (Sweden)

    CJ Ley

    2014-03-01

    Full Text Available Osteochondral lesions in the joints of the distal tarsal region of young Icelandic horses provide a natural model for the early stages of osteoarthritis (OA in low-motion joints. We describe and characterise mineralised and non-mineralised osteochondral lesions in left distal tarsal region joint specimens from twenty-two 30 ±1 month-old Icelandic horses. Combinations of confocal scanning light microscopy, backscattered electron scanning electron microscopy (including, importantly, iodine staining and three-dimensional microcomputed tomography were used on specimens obtained with guidance from clinical imaging. Lesion-types were described and classified into groups according to morphological features. Their locations in the hyaline articular cartilage (HAC, articular calcified cartilage (ACC, subchondral bone (SCB and the joint margin tissues were identified and their frequency in the joints recorded. Associations and correlations between lesion-types were investigated for centrodistal joints only. In centrodistal joints the lesion-types HAC chondrocyte loss, HAC fibrillation, HAC central chondrocyte clusters, ACC arrest and ACC advance had significant associations and strong correlations. These lesion-types had moderate to high frequency in centrodistal joints but low frequencies in tarsometatarsal and talocalcaneal-centroquartal joints. Joint margin lesion-types had no significant associations with other lesion-types in the centrodistal joints but high frequency in both the centrodistal and tarsometatarsal joints. The frequency of SCB lesion-types in all joints was low. Hypermineralised infill phase lesion-types were detected. Our results emphasise close associations between HAC and ACC lesions in equine centrodistal joints and the importance of ACC lesions in the development of OA in low-motion compression-loaded equine joints.

  6. Osteochondral lesions in distal tarsal joints of Icelandic horses reveal strong associations between hyaline and calcified cartilage abnormalities.

    Science.gov (United States)

    Ley, C J; Ekman, S; Hansson, K; Björnsdóttir, S; Boyde, A

    2014-03-25

    Osteochondral lesions in the joints of the distal tarsal region of young Icelandic horses provide a natural model for the early stages of osteoarthritis (OA) in low-motion joints. We describe and characterise mineralised and non-mineralised osteochondral lesions in left distal tarsal region joint specimens from twenty-two 30 ±1 month-old Icelandic horses. Combinations of confocal scanning light microscopy, backscattered electron scanning electron microscopy (including, importantly, iodine staining) and three-dimensional microcomputed tomography were used on specimens obtained with guidance from clinical imaging. Lesion-types were described and classified into groups according to morphological features. Their locations in the hyaline articular cartilage (HAC), articular calcified cartilage (ACC), subchondral bone (SCB) and the joint margin tissues were identified and their frequency in the joints recorded. Associations and correlations between lesion-types were investigated for centrodistal joints only. In centrodistal joints the lesion-types HAC chondrocyte loss, HAC fibrillation, HAC central chondrocyte clusters, ACC arrest and ACC advance had significant associations and strong correlations. These lesion-types had moderate to high frequency in centrodistal joints but low frequencies in tarsometatarsal and talocalcaneal-centroquartal joints. Joint margin lesion-types had no significant associations with other lesion-types in the centrodistal joints but high frequency in both the centrodistal and tarsometatarsal joints. The frequency of SCB lesion-types in all joints was low. Hypermineralised infill phase lesion-types were detected. Our results emphasise close associations between HAC and ACC lesions in equine centrodistal joints and the importance of ACC lesions in the development of OA in low-motion compression-loaded equine joints.

  7. Orbital atherectomy for severely calcified lesions: More dissections in women but similar 30-day outcomes to men.

    Science.gov (United States)

    Chandrasekhar, Jaya; Mehran, Roxana

    2016-03-01

    Calcified lesions are associated with lower rates of successful percutaneous coronary intervention (PCI), greater stent thrombosis, and increased target vessel revascularization. Women undergoing PCI are more often older than men and likely to present with severe lesion calcification. The ORBIT II study, for the first time compares the effect of the orbital atherectomy system (OAS) in men and women undergoing PCI for severely calcified lesions. Although the adjusted risk of severe dissections was higher in women, the incidence of in-hospital and 30-day outcomes was similar to men. Randomized comparisons of the OAS with rotational atherectomy and with stenting without atherectomy are needed to further elucidate sex-based differences in calcified lesion PCI. © 2016 Wiley Periodicals, Inc.

  8. Evidence for calcifying nanoparticles in gingival crevicular fluid and dental calculus in periodontitis.

    Science.gov (United States)

    Zhang, Song-Mei; Tian, Fei; Jiang, Xin-Quan; Li, Jing; Xu, Chun; Guo, Xiao-Kui; Zhang, Fu-Qiang

    2009-09-01

    Calcifying nanoparticles (CNPs), also known as nanobacteria, can produce carbonate apatite on their cell walls and initiate pathologic calcification. The objective of this study was to determine whether CNPs are present in the gingival crevicular fluid (GCF) from subjects with periodontal disease and whether they can induce the pathologic calcification of primary cultured human gingival epithelial cells. GCF and dental calculus samples were collected from 10 subjects with gingivitis and 10 subjects with chronic periodontitis. CNPs in GCF and calculus filtrates were detected with nanocapture enzyme-linked immunosorbent assay kits. The CNPs in cultures of dental calculus filtrates were also identified using immunofluorescence staining, transmission electron microscopy (TEM), and chemical analysis. Pathologic changes in the CNP-treated gingival epithelial cells were observed with TEM, alizarin red staining, and disk-scanning confocal microscopy. CNPs were found in GCF samples from two subjects with chronic periodontitis. Based on chemical analysis, the surface-associated material from CNPs isolated and cultured from calculus has a composition similar to dental calculus. The pathologic calcification of CNP-treated gingival epithelial cells was also observed. Self-replicating calcifying nanoparticles can be cultured and identified from dental calculus. This raises the issue of whether CNPs contribute to the pathogenesis of periodontitis.

  9. Three-year results after directional atherectomy of calcified stenotic lesions of the superficial femoral artery.

    Science.gov (United States)

    Minko, P; Buecker, A; Jaeger, S; Katoh, M

    2014-10-01

    To investigate the 3-year outcome of patients with peripheral arterial disease (PAD) and heavily calcified stenotic lesions of the superficial femoral artery after directional atherectomy. Fifty-three patients (mean age 67 ± 10 years; 18 females, 35 males, TASC B and C, mean lesion length 7.9 ± 3.5 cm) with PAD (Rutherford 2-6) were enrolled into this prospective monocentric study. In total, 59 calcified lesions of the superficial femoral artery were treated with the Silverhawk atherectomy device (Covidien, Plymouth, MN, USA). Patients were followed-up for 36 months with a 6-month interval to perform clinical re-evaluation, including measurement of maximum walking distance and ankle-brachial index (ABI) as well as duplex-sonography. The primary success rate of the procedure was 92 %. In five cases (8 %), additional balloon-PTA and/or stent-PTA was necessary. Procedure-related embolization occurred in seven cases (12 %), which were all successfully treated by aspiration. The primary patency rate after 3 years was 55 %. Median Rutherford score decreased significantly from 5 to 0 after 36 months (p atherectomy was successfully applied to decrease the plaque burden. Results after 3 years showed a significant decrease of Rutherford score with persistent improvement of ABI and reasonable patency rate.

  10. Expression of uPA, tPA, and PAI-1 in Calcified Aortic Valves

    Directory of Open Access Journals (Sweden)

    Najlah Kochtebane

    2014-01-01

    Full Text Available Purpose. Our physiopathological assumption is that u-PA, t-PA, and PAI-1 are released by calcified aortic valves and play a role in the calcification of these valves. Methods. Sixty-five calcified aortic valves were collected from patients suffering from aortic stenosis. Each valve was incubated for 24 hours in culture medium. The supernatants were used to measure u-PA, t-PA, and PAI-1 concentrations; the valve calcification was evaluated using biphotonic absorptiometry. Results. Aortic stenosis valves expressed normal plasminogen activators concentrations and overexpressed PAI-1 (u-PA, t-PA, and PAI-1 mean concentrations were, resp., 1.69 ng/mL ± 0.80, 2.76 ng/mL ± 1.33, and 53.27 ng/mL ± 36.39. There was no correlation between u-PA and PAI-1 (r=0.3 but t-PA and PAI-1 were strongly correlated with each other (r=0.6. Overexpression of PAI-1 was proportional to the calcium content of the AS valves. Conclusions. Our results demonstrate a consistent increase of PAI-1 proportional to the calcification. The overexpression of PAI-1 may be useful as a predictive indicator in patients with aortic stenosis.

  11. Hydroxyapatite and Calcified Elastin Induce Osteoblast-like Differentiation in Rat Aortic Smooth Muscle Cells

    Science.gov (United States)

    Lei, Yang; Sinha, Aditi; Nosoudi, Nasim; Grover, Ankit; Vyavahare, Naren

    2014-01-01

    Vascular calcification can be categorized into two different types. Intimal calcification related to atherosclerosis and elastin-specific medial arterial calcification (MAC). Osteoblast-like differentiation of vascular smooth muscle cells (VSMCs) has been shown in both types; however, how this relates to initiation of vascular calcification is unclear. We hypothesize that the initial deposition of hydroxyapatite-like mineral in MAC occurs on degraded elastin first and that causes osteogenic transformation of VSMCs. To test this, rat aortic smooth muscle cells (RASMCs) were cultured on hydroxyapatite crystals and calcified aortic elastin. Using RT-PCR and specific protein assays, we demonstrate that RASMCs lose their smooth muscle lineage markers like alpha smooth muscle actin (SMA) and myosin heavy chain (MHC) and undergo chondrogenic/osteogenic transformation. This is indicated by an increase in the expression of typical chondrogenic proteins such as aggrecan, collagen type II alpha 1(Col2a1) and bone proteins such as runt-related transcription factor 2 (RUNX2), alkaline phosphatase (ALP) and osteocalcin (OCN). Furthermore, when calcified conditions are removed, cells return to their original phenotype. Our data supports the hypothesis that elastin degradation and calcification precedes VSMCs' osteoblast-like differentiation. PMID:24447384

  12. [Radial shock wave therapy in calcifying tendinitis of the rotator cuff--a prospective study].

    Science.gov (United States)

    Magosch, P; Lichtenberg, S; Habermeyer, P

    2003-01-01

    The aim of the study is to evaluate the influence of radial shock wave therapy (RSWT) on the course of calcifying tendinitis of the rotator cuff. 35 patients with a mean age of 47.5 years suffering from calcifying tendinitis stage Gaertner 2 with a mean size of 16.6 mm in typical location (true-ap view) for a mean of 28 months were treated by low-energy RSWT three times. The acromio-humeral distance averaged 10.4 mm measured at the true-ap view. All patients were clinically and radiologically followed-up at 4 weeks, 3, 6 and 12 months after the last treatment. The Constant score improved significantly (p energy RSWT leads within the first 4 weeks to a significant pain relief and an improvement of shoulder function. In consideration of the long history, the size and the spontaneous resorption rate of the calcific deposit, an inductive effect of RSWT on the resorption of the calcific deposit can be assumed.

  13. Valve-Like and Protruding Calcified Intimal Flap Complicating Common Iliac Arteries Kissing Stenting

    Directory of Open Access Journals (Sweden)

    George S. Georgiadis

    2015-01-01

    Full Text Available Endovascular therapy for iliac artery chronic total occlusions is nowadays associated with low rates of procedure-related complications and improved clinical outcomes, and it is predominantly used as first-line therapy prior to aortobifemoral bypass grafting. Herein, we describe the case of a patient presenting with an ischemic left foot digit ulcer and suffering complex aortoiliac lesions, who received common iliac arteries kissing stents, illustrating at final antegrade and retrograde angiograms the early recognition of a blood flow obstructing valve-like calcified intimal flap protruding through the stent struts, which was obstructing antegrade but not retrograde unilateral iliac arterial axis blood flow. The problem was resolved by reconstructing the aortic bifurcation at a more proximal level. Completion angiogram verified normal patency of aorta and iliac vessels. Additionally, a severe left femoral bifurcation stenosis was also corrected by endarterectomy-arterioplasty with a bovine patch. Postintervention ankle brachial pressure indices were significantly improved. At the 6-month and 2-year follow-up, normal peripheral pulses were still reported without intermittent claudication suggesting the durability of the procedure. Through stent-protruding calcified intimal flap, is a very rare, but existing source of antegrade blood flow obstruction after common iliac arteries kissing stents.

  14. Calcifying algae maintain settlement cues to larval abalone following algal exposure to extreme ocean acidification.

    Science.gov (United States)

    O'Leary, Jennifer K; Barry, James P; Gabrielson, Paul W; Rogers-Bennett, Laura; Potts, Donald C; Palumbi, Stephen R; Micheli, Fiorenza

    2017-07-18

    Ocean acidification (OA) increasingly threatens marine systems, and is especially harmful to calcifying organisms. One important question is whether OA will alter species interactions. Crustose coralline algae (CCA) provide space and chemical cues for larval settlement. CCA have shown strongly negative responses to OA in previous studies, including disruption of settlement cues to corals. In California, CCA provide cues for seven species of harvested, threatened, and endangered abalone. We exposed four common CCA genera and a crustose calcifying red algae, Peyssonnelia (collectively CCRA) from California to three pCO 2 levels ranging from 419-2,013 µatm for four months. We then evaluated abalone (Haliotis rufescens) settlement under ambient conditions among the CCRA and non-algal controls that had been previously exposed to the pCO 2 treatments. Abalone settlement and metamorphosis increased from 11% in the absence of CCRA to 45-69% when CCRA were present, with minor variation among CCRA genera. Though all CCRA genera reduced growth during exposure to increased pCO 2 , abalone settlement was unaffected by prior CCRA exposure to increased pCO 2 . Thus, we find no impacts of OA exposure history on CCRA provision of settlement cues. Additionally, there appears to be functional redundancy in genera of CCRA providing cues to abalone, which may further buffer OA effects.

  15. δ11B as monitor of calcification site pH in divergent marine calcifying organisms

    Directory of Open Access Journals (Sweden)

    J. N. Sutton

    2018-03-01

    Full Text Available The boron isotope composition (δ11B of marine biogenic carbonates has been predominantly studied as a proxy for monitoring past changes in seawater pH and carbonate chemistry. However, a number of assumptions regarding chemical kinetics and thermodynamic isotope exchange reactions are required to derive seawater pH from δ11B biogenic carbonates. It is also probable that δ11B of biogenic carbonate reflects seawater pH at the organism's site of calcification, which may or may not reflect seawater pH. Here, we report the development of methodology for measuring the δ11B of biogenic carbonate samples at the multi-collector inductively coupled mass spectrometry facility at Ifremer (Plouzané, France and the evaluation of δ11BCaCO3 in a diverse range of marine calcifying organisms reared for 60 days in isothermal seawater (25 °C equilibrated with an atmospheric pCO2 of ca. 409 µatm. Average δ11BCaCO3 composition for all species evaluated in this study range from 16.27 to 35.09 ‰, including, in decreasing order, coralline red alga Neogoniolithion sp. (35.89 ± 3.71 ‰, temperate coral Oculina arbuscula (24.12 ± 0.19 ‰, serpulid worm Hydroides crucigera (19.26 ± 0.16 ‰, tropical urchin Eucidaris tribuloides (18.71 ± 0.26 ‰, temperate urchin Arbacia punctulata (16.28 ± 0.86 ‰, and temperate oyster Crassostrea virginica (16.03 ‰. These results are discussed in the context of each species' proposed mechanism of biocalcification and other factors that could influence skeletal and shell δ11B, including calcifying site pH, the proposed direct incorporation of isotopically enriched boric acid (instead of borate into biogenic calcium carbonate, and differences in shell/skeleton polymorph mineralogy. We conclude that the large inter-species variability in δ11BCaCO3 (ca. 20 ‰ and significant discrepancies between measured δ11BCaCO3 and δ11BCaCO3 expected from established relationships

  16. Orbital atherectomy for treating de novo, severely calcified coronary lesions: 3-year results of the pivotal ORBIT II trial.

    Science.gov (United States)

    Lee, Michael; Généreux, Philippe; Shlofmitz, Richard; Phillipson, Daniel; Anose, Bynthia M; Martinsen, Brad J; Himmelstein, Stevan I; Chambers, Jeff W

    2017-06-01

    The presence of heavy coronary artery calcification increases the complexity of percutaneous coronary intervention (PCI) and increases the incidence of major adverse cardiac events (MACE): death, myocardial infarction (MI), target vessel revascularization (TVR), and stent thrombosis. The ORBIT II (Evaluate the Safety and Efficacy of OAS in Treating Severely Calcified Coronary Lesions) trial reported low rates of procedural, 30-day, 1-year, and 2-year ischemic complications after treatment of de novo, severely calcified lesions with the Diamondback 360° Coronary Orbital Atherectomy System (OAS) (Cardiovascular Systems, Inc.). ORBIT II was a single-arm trial that enrolled 443 patients at 49U.S. sites; in this study, de novo, severely calcified coronary lesions were treated with OAS prior to stenting. The primary safety endpoint was 30-day MACE: the composite of cardiac death, MI, and TVR (inclusive of target lesion revascularization (TLR)). The primary efficacy endpoint was procedural success: stent delivery with a residual stenosis of atherectomy. There were 360 (81.3%) subjects who completed the protocol-mandated 3-year visit.The overall cumulative rate of 3-year MACE was 23.5%, including cardiac death (6.7%), MI (11.2%), and TVR (10.2%). The 3-year target lesion revascularization rate was 7.8%. In the final 3-year analysis of the ORBIT II trial, orbital atherectomy of severely calcified coronary lesions followed by stenting resulted in a low rate of adverse ischemic events compared with historical controls.Orbital atherectomy represents a safe and effective revascularization strategy for patients with severely calcified coronary lesions. The ORBIT II trial enrolled 443 subjects to study orbital atherectomy followed by stenting for de novo severely calcified coronary lesions. The overall cumulative 3-year MACE rate was 23.5%, including cardiac death (6.7%), MI (11.2%), and TVR (10.2%); the 3-year target lesion revascularization rate was 7.8%. Orbital atherectomy

  17. Soft and hard pomerons

    International Nuclear Information System (INIS)

    Maor, Uri; Tel Aviv Univ.

    1995-09-01

    The role of s-channel unitarity screening corrections, calculated in the eikonal approximation, is investigated for soft Pomeron exchange responsible for elastic and diffractive hadron scattering in the high energy limit. We examine the differences between our results and those obtained from the supercritical Pomeron-Regge model with no such corrections. It is shown that screening saturation is attained at different scales for different channels. We then proceed to discuss the new HERA data on hard (PQCD) Pomeron diffractive channels and discuss the relationship between the soft and hard Pomerons and the relevance of our analysis to this problem. (author). 18 refs, 9 figs, 1 tab

  18. Hard exclusive QCD processes

    Energy Technology Data Exchange (ETDEWEB)

    Kugler, W.

    2007-01-15

    Hard exclusive processes in high energy electron proton scattering offer the opportunity to get access to a new generation of parton distributions, the so-called generalized parton distributions (GPDs). This functions provide more detailed informations about the structure of the nucleon than the usual PDFs obtained from DIS. In this work we present a detailed analysis of exclusive processes, especially of hard exclusive meson production. We investigated the influence of exclusive produced mesons on the semi-inclusive production of mesons at fixed target experiments like HERMES. Further we give a detailed analysis of higher order corrections (NLO) for the exclusive production of mesons in a very broad range of kinematics. (orig.)

  19. Hard-hat day

    CERN Multimedia

    2003-01-01

    CERN will be organizing a special information day on Friday, 27th June, designed to promote the wearing of hard hats and ensure that they are worn correctly. A new prevention campaign will also be launched.The event will take place in the hall of the Main Building from 11.30 a.m. to 2.00 p.m., when you will be able to come and try on various models of hard hat, including some of the very latest innovative designs, ask questions and pass on any comments and suggestions.

  20. Biogeochemical analysis of the calcification patterns of cold-water corals Madrepora oculata and Lophelia pertusa along contact surfaces with calcified tubes of the symbiotic polychaete Eunice norvegica: Evaluation of a 'mucus' calcification hypothesis

    Science.gov (United States)

    Oppelt, Alexandra; López Correa, Matthias; Rocha, Carlos

    2017-09-01

    The scleractinian cold-water corals (CWCs), including the species Madrepora oculata and especially Lophelia pertusa, have been studied extensively in an attempt to decipher environmental signals recorded during biomineralisation in order to extract environmental chronologies. However, understanding the mechanisms of carbonate precipitation is a prerequisite to interpret variations in geochemical signatures locked into the skeleton during coral growth; to date results are still inconclusive. Here a novel approach, comparing the calcification patterns within the coral microstructure of species L. pertusa and M. oculata and the geochemistry along the contact surfaces with calcified polychaete tubes is undertaken to provide additional information on the mechanisms of biomineralisation in colonial corals. The fact that no significant difference in microstructures, variations in growth rate, or geochemical composition between the corallite theca and the calcified polychaete tube was detectable leads to the conclusion that both have been deposited by the coral tissue in L. pertusa and M. oculata. Based on prior knowledge on the symbiotic relationship between CWCs and the polychaete Eunice norvegica, an involvement of mucus in the calcification of the parchment tubes had been suspected. However, we found only evidence for aragonite precipitated by coral tissue, without evidence for an involvement of mucus in the calcification.

  1. Preoperative computed tomography of the chest in lung cancer patients: the predictive value of calcified lymph nodes for the perioperative outcomes of video-assisted thoracoscopic surgery lobectomy

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Kwang Nam; Lee, Youkyung; Wi, Jae Yeon [Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of); Moon, Hyeon-Jong; Sung, Yong Won [Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Department of Cardiothoracic Surgery, Seoul (Korea, Republic of)

    2013-12-15

    To determine the predictive value of identifying calcified lymph nodes (LNs) for the perioperative outcomes of video-assisted thoracoscopic surgery (VATS). Fifty-six consecutive patients who underwent VATS lobectomy for lung cancer were included. We evaluated the number and location of calcified LNs on computed tomography (CT). We investigated clinical parameters, including percentage forced expiratory volume in 1 s (FEV{sub 1}%), surgery duration, chest tube indwelling duration, and length of hospital stay. We performed linear regression analysis and multiple comparisons of perioperative outcomes. Mean number of calcified LNs per patient was 0.9 (range, 0-6), mostly located in the hilar-interlobar zone (43.8 %). For surgery duration (mean, 5.0 h), FEV{sub 1}% and emphysema severity were independent predictors (P = 0.010 and 0.003, respectively). The number of calcified LNs was an independent predictor for chest tube indwelling duration (P = 0.030) and length of hospital stay (P = 0.046). Mean duration of chest tube indwelling and hospital stay was 8.8 days and 12.7 days in no calcified LN group; 9.2 and 13.2 in 1 calcified LN group; 12.8 and 19.7 in {>=}2 calcified LNs group, respectively. The presence of calcified LNs on CT can help predict more complicated perioperative course following VATS lobectomy. (orig.)

  2. Hard times; Schwere Zeiten

    Energy Technology Data Exchange (ETDEWEB)

    Grunwald, Markus

    2012-10-02

    The prices of silicon and solar wafers keep dropping. According to market research specialist IMS research, this is the result of weak traditional solar markets and global overcapacities. While many manufacturers are facing hard times, big producers of silicon are continuing to expand.

  3. Hardness of Clustering

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Hardness of Clustering. Both k-means and k-medians intractable (when n and d are both inputs even for k =2). The best known deterministic algorithms. are based on Voronoi partitioning that. takes about time. Need for approximation – “close” to optimal.

  4. Rock-hard coatings

    OpenAIRE

    Muller, M.

    2007-01-01

    Aircraft jet engines have to be able to withstand infernal conditions. Extreme heat and bitter cold tax coatings to the limit. Materials expert Dr Ir. Wim Sloof fits atoms together to develop rock-hard coatings. The latest invention in this field is known as ceramic matrix composites. Sloof has signed an agreement with a number of parties to investigate this material further.

  5. Rock-hard coatings

    NARCIS (Netherlands)

    Muller, M.

    2007-01-01

    Aircraft jet engines have to be able to withstand infernal conditions. Extreme heat and bitter cold tax coatings to the limit. Materials expert Dr Ir. Wim Sloof fits atoms together to develop rock-hard coatings. The latest invention in this field is known as ceramic matrix composites. Sloof has

  6. Hardness and excitation energy

    Indian Academy of Sciences (India)

    It is shown that the first excitation energy can be given by the Kohn-Sham hardness (i.e. the energy difference of the ground-state lowest unoccupied and highest occupied levels) plus an extra term coming from the partial derivative of the ensemble exchange-correlation energy with respect to the weighting factor in the ...

  7. Quantification by optical coherence tomography imaging of the ablation volume obtained with the Orbital Atherectomy System in calcified coronary lesions

    NARCIS (Netherlands)

    Sotomi, Yohei; Cavalcante, Rafael; Shlofmitz, Richard A.; Suwannasom, Pannipa; Tateishi, Hiroki; Tenekecioglu, Erhan; Zheng, Yaping; Abdelghani, Mohammad; de Winter, Robbert J.; Wykrzykowska, Joanna J.; Onuma, Yoshinobu; Serruys, Patrick W.

    2016-01-01

    Recently, favourable procedural 30-day and one-year outcomes with the Diamondback 360 Orbital Atherectomy System (OAS) in the treatment of severely calcified lesions have been reported. The purpose of this study was to assess the therapeutic mechanism and efficacy of the OAS with optical coherence

  8. Surgical Management of Calcified Liver Hydatid Cyst Complicated with Thoracobiliary Fistula: A Case Series and Literature Review

    Directory of Open Access Journals (Sweden)

    Mohsen Sokouti

    2016-06-01

    Full Text Available Thoracobiliary fistula is a rare complication of hydatid cyst of the liver especially in the calcified form. Surgery is the only medical option. The treatment consists of radical surgical procedures in the majority of the patients. Conservative surgical treatments are performed with high mortality rate. Herein, we will describe two patients of calcified hydatid cysts of the liver whose condition becomes complicated with Thoracobiliary fistula. The first patient was treated with right thoracotomy and resection of pleural hydatid cysts. Then, were evacuated the ruptured laminated membrane and daughter cysts of infected hepatic hydatid cysts through diaphragmatic opening and sub diaphragmatic drainage of the calcified liver hydatid cyst. The second patient was also treated with right thoracotomy, resection of pulmonary hydatid cysts, evacuation of ruptured bile stained laminated membrane and daughter cysts of hepatic hydatid cysts through diaphragmatic opening and sub diaphragmatic drainage of the calcified cyst cavity. Our patients underwent conservative surgery which posed a severe risk. Both cases are discussed together with review of the literature.

  9. Hard Copy Market Overview

    Science.gov (United States)

    Testan, Peter R.

    1987-04-01

    A number of Color Hard Copy (CHC) market drivers are currently indicating strong growth in the use of CHC technologies for the business graphics marketplace. These market drivers relate to product, software, color monitors and color copiers. The use of color in business graphics allows more information to be relayed than is normally the case in a monochrome format. The communicative powers of full-color computer generated output in the business graphics application area will continue to induce end users to desire and require color in their future applications. A number of color hard copy technologies will be utilized in the presentation graphics arena. Thermal transfer, ink jet, photographic and electrophotographic technologies are all expected to be utilized in the business graphics presentation application area in the future. Since the end of 1984, the availability of color application software packages has grown significantly. Sales revenue generated by business graphics software is expected to grow at a compound annual growth rate of just over 40 percent to 1990. Increased availability of packages to allow the integration of text and graphics is expected. Currently, the latest versions of page description languages such as Postscript, Interpress and DDL all support color output. The use of color monitors will also drive the demand for color hard copy in the business graphics market place. The availability of higher resolution screens is allowing color monitors to be easily used for both text and graphics applications in the office environment. During 1987, the sales of color monitors are expected to surpass the sales of monochrome monitors. Another major color hard copy market driver will be the color copier. In order to take advantage of the communications power of computer generated color output, multiple copies are required for distribution. Product introductions of a new generation of color copiers is now underway with additional introductions expected

  10. Orbital Atherectomy for Treating De Novo Severely Calcified Coronary Narrowing (1-Year Results from the Pivotal ORBIT II Trial).

    Science.gov (United States)

    Généreux, Philippe; Lee, Arthur C; Kim, Christopher Y; Lee, Michael; Shlofmitz, Richard; Moses, Jeffrey W; Stone, Gregg W; Chambers, Jeff W

    2015-06-15

    Percutaneous coronary intervention of severely calcified lesions has historically been associated with major adverse cardiac event (MACE) rates as high as 30%. In the ORBIT II (Evaluate the Safety and Efficacy of OAS in Treating Severely Calcified Coronary Lesions) trial, treatment of de novo severely calcified lesions with the Diamondback 360° Coronary Orbital Atherectomy System (OAS) resulted in low rates of procedural and 30-day adverse ischemic events. The long-term results from this trial have not been reported. We sought to determine the 1-year outcomes after orbital atherectomy of severely calcified coronary lesions. ORBIT II was a single-arm trial enrolling 443 subjects at 49 US sites with severely calcified lesions usually excluded from randomized trials. OAS utilizes a centrifugal differential sanding mechanism of action for plaque modification prior to stent implantation. After OAS drug-eluting stents were implanted in 88.2% of the patients. The primary safety end point was 30-day MACE, the composite of cardiac death, myocardial infarction, or target vessel revascularization [TVR]. The present analysis reports the 1-year follow-up results from ORBIT II. One-year data were available in 433 of 443 patients (97.7%), with median follow-up time of 16.7 months. The 1-year MACE rate was 16.4%, including cardiac death (3.0%), myocardial infarction (9.7%), and target vessel revascularization (5.9%). The 1-year target lesion revascularization rate was 4.7%, and stent thrombosis occurred in 1 patient (0.2%). Independent predictors of 1-year MACE and target vessel revascularization were diameter stenosis at baseline and the use of bare-metal stents. In patients with severely calcified lesions who underwent percutaneous coronary intervention, the use of OAS was associated with low rates of 1-year adverse ischemic events compared with historical controls. This finding has important clinical implications for the selection of optimum treatment strategies for patients

  11. Dental calculus: the calcified biofilm and its role in disease development.

    Science.gov (United States)

    Akcalı, Aliye; Lang, Niklaus P

    2018-02-01

    Dental calculus represents the first fossilized record of bacterial communities as a testimony of evolutionary biology. The development of dental calculus is a dynamic process that starts with a nonmineralized biofilm which eventually calcifies. Nonmineralized dental biofilm entraps particles from the oral cavity, including large amounts of oral bacteria, human proteins, viruses and food remnants, and preserves their DNA. The process of mineralization involves metabolic activities of the bacterial colonies and strengthens the attachment of nonmineralized biofilms to the tooth surface. From a clinical point of view, dental calculus always harbors a living, nonmineralized biofilm, jeopardizing the integrity of the dento-gingival or implanto-mucosal unit. This narrative review presents a brief historical overview of dental calculus formation and its clinical relevance in modern periodontal practice. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. A Tortuous Process of Surgical Treatment for a Large Calcified Chronic Subdural Hematoma.

    Science.gov (United States)

    Li, Huan; Mao, Xiang; Tao, Xiao-Gang; Li, Jing-Sheng; Liu, Bai-Yun; Wu, Zhen

    2017-12-01

    Calcified chronic subdural hematoma (CCSDH) is a rare disease for which no standard approach to treatment has been established. Reports covering both burr hole trepanation and craniotomy for CCSDH are rare. Furthermore, infection of CCSDH after the burr hole trepanation has not been reported in the literature. A 61-year-old man presented with left frontotemporoparietal CCSDH demonstrated on computed tomography (CT) scan. The patient underwent 2 separate burr hole trepanations with intraoperative irrigation and postoperative drainage. These procedures led to infection of the CCSDH. The patient eventually underwent an open craniotomy to provide complete removal of the hematoma. Owing to the complex contents of a CCSDH, burr hole trepanation cannot adequately drain the hematoma or relieve the mass effect. Craniotomy is a much more reliable approach for achieving complete resection of a CCSDH. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Coral calcifying fluid pH dictates response to ocean acidification.

    Science.gov (United States)

    Holcomb, M; Venn, A A; Tambutté, E; Tambutté, S; Allemand, D; Trotter, J; McCulloch, M

    2014-06-06

    Ocean acidification driven by rising levels of CO2 impairs calcification, threatening coral reef growth. Predicting how corals respond to CO2 requires a better understanding of how calcification is controlled. Here we show how spatial variations in the pH of the internal calcifying fluid (pHcf) in coral (Stylophora pistillata) colonies correlates with differential sensitivity of calcification to acidification. Coral apexes had the highest pHcf and experienced the smallest changes in pHcf in response to acidification. Lateral growth was associated with lower pHcf and greater changes with acidification. Calcification showed a pattern similar to pHcf, with lateral growth being more strongly affected by acidification than apical. Regulation of pHcf is therefore spatially variable within a coral and critical to determining the sensitivity of calcification to ocean acidification.

  14. Calcium homeostasis and vitamin D metabolism and expression in strongly calcifying laying birds.

    Science.gov (United States)

    Bar, Arie

    2008-12-01

    Egg laying and shell calcification impose severe extra demands on ionic calcium (Ca2+) homeostasis; especially in birds characterized by their long clutches (series of eggs laid sequentially before a "pause day"). These demands induce vitamin D metabolism and expression. The metabolism of vitamin D is also altered indirectly, by other processes associated with increased demands for calcium, such as growth, bone formation and egg production. A series of intestinal, renal or bone proteins are consequently expressed in the target organs via mechanisms involving a vitamin D receptor. Some of these proteins (carbonic anhydrase, calbindin and calcium-ATPase) are also found in the uterus (eggshell gland) or are believed to be involved in calcium transport in the intestine or kidney (calcium channels). The present review deals with vitamin D metabolism and the expression of the above-mentioned proteins in birds, with special attention to the strongly calcifying laying bird.

  15. Discovery of the mineral brucite (magnesium hydroxide) in the tropical calcifying alga Polystrata dura (Peyssonneliales, Rhodophyta).

    Science.gov (United States)

    Nash, Merinda C; Russell, Bayden D; Dixon, Kyatt R; Liu, Minglu; Xu, Huifang

    2015-06-01

    Red algae of the family Peyssonneliaceae typically form thin crusts impregnated with aragonite. Here, we report the first discovery of brucite in a thick red algal crust (~1 cm) formed by the peyssonnelioid species Polystrata dura from Papua New Guinea. Cells of P. dura were found to be infilled by the magnesium-rich mineral brucite [Mg(OH)2 ]; minor amounts of magnesite and calcite were also detected. We propose that cell infill may be associated with the development of thick (> ~5 mm) calcified red algal crusts, integral components of tropical biotic reefs. If brucite infill within the P. dura crust enhances resistance to dissolution similarly to crustose coralline algae that infill with dolomite, then these crusts would be more resilient to future ocean acidification than crusts without infill. © 2015 Phycological Society of America.

  16. Acidification and warming affect both a calcifying predator and prey, but not their interaction

    DEFF Research Database (Denmark)

    Landes, Anja; Zimmer, Martin

    2012-01-01

    Both ocean warming and acidification have been demonstrated to affect the growth, performance and reproductive success of calcifying invertebrates. However, relatively little is known regarding how such environmental change may affect interspecific interactions. We separately treated green crabs...... to environmental change. Acidification negatively affected the closer-muscle length of the crusher chela and correspondingly the claw-strength increment in C. maenas. The effects of warming and/or acidification on L. littorea were less consistent but indicated weaker shells in response to acidification...... Carcinus maenas and periwinkles Littorina littorea under conditions that mimicked either ambient conditions (control) or warming and acidification, both separately and in combination, for 5 mo. After 5 mo, the predators, prey and predator-prey interactions were screened for changes in response...

  17. Prevalence, Predictors, and Clinical Presentation of a Calcified Nodule as Assessed by Optical Coherence Tomography.

    Science.gov (United States)

    Lee, Tetsumin; Mintz, Gary S; Matsumura, Mitsuaki; Zhang, Wenbin; Cao, Yang; Usui, Eisuke; Kanaji, Yoshihisa; Murai, Tadashi; Yonetsu, Taishi; Kakuta, Tsunekazu; Maehara, Akiko

    2017-08-01

    This study sought to determine the anatomic characteristics and clinical presentation associated with a calcified nodule (CN) as assessed by optical coherence tomography. CN is an unusual but demonstrable cause of acute coronary syndromes (ACS). We studied 889 de novo culprit lesions in 889 patients (48% ACS) who underwent optical coherence tomography before intervention. CN was defined as an eruptive accumulation of nodular calcification (small fractured calcifications). Using quantitative coronary angiography, the change in the angle of the lesion between diastole and systole was measured (angiographic Δ angle). CN was seen in 4.2% of all lesions and was located more frequently in the ostial or mid right coronary artery. Hemodialysis (odds ratio: 4.0; 95% confidence interval: 1.1 to 13.4; p = 0.04), in-lesion angiographic Δ angle (odds ratio: 1.09; 95% confidence interval: 1.05 to 1.14; p presentation, there was a smaller minimum lumen area (1.04 mm 2 [first quartile, third quartile: 0.69, 1.26] vs. 1.61 [first quartile, third quartile: 1.03, 2.06] mm 2 ; p = 0.02) accompanied by more thrombus (82.4% vs. 20.0%; p presentation. In lesions with severe calcification (maximum calcium arc >180°), 30% of ACS culprit lesions contained a CN, and the presence of a CN was associated with ACS presentation independent of other vulnerable plaque morphologies. The presence of a CN was associated with severe calcification and larger hinge movement of the coronary artery (especially ostial and mid right coronary artery). One-third of the underlying plaque morphology of severely calcified culprit lesions in patients with ACS was caused by a CN. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Hard Electromagnetic Processes

    International Nuclear Information System (INIS)

    Richard, F.

    1987-09-01

    Among hard electromagnetic processes, I will use the most recent data and focus on quantitative test of QCD. More specifically, I will retain two items: - hadroproduction of direct photons, - Drell-Yan. In addition, I will briefly discuss a recent analysis of ISR data obtained with AFS (Axial Field Spectrometer) which sheds a new light on the e/π puzzle at low P T

  19. Percutaneous Coronary Intervention in Severely Calcified Unprotected Left Main Coronary Artery Disease: Initial Experience With Orbital Atherectomy.

    Science.gov (United States)

    Lee, Michael S; Shlofmitz, Evan; Kaplan, Barry; Shlofmitz, Richard

    2016-04-01

    We report the clinical outcomes of patients who underwent percutaneous coronary intervention (PCI) with orbital atherectomy for severely calcified unprotected left main coronary artery (ULMCA) disease. Although surgical revascularization is the gold standard for patients with ULMCA disease, not all patients are candidates for this. PCI is increasingly used to treat complex coronary artery disease, including ULMCA disease. The presence of severely calcified lesions increases the complexity of PCI. Orbital atherectomy can be used to facilitate stent delivery and expansion in severely calcified lesions. The clinical outcomes of patients treated with orbital atherectomy for severely calcified ULMCA disease have not been reported. From May 2014 to July 2015, a total of 14 patients who underwent PCI with orbital atherectomy for ULMCA disease were retrospectively evaluated. The primary endpoint was major cardiac and cerebrovascular event (cardiac death, myocardial infarction, stroke, and target-lesion revascularization) at 30 days. The mean age was 78.2 ± 5.8 years. The mean ejection fraction was 41.8 ± 19.8%. Distal bifurcation disease was present in 9 of 14 patients. Procedural success was achieved in all 14 patients. The 30-day major adverse cardiac and cerebrovascular event rate was 0%. One patient had coronary dissection that was successfully treated with stenting. No patient had perforation, slow flow, or thrombosis. Orbital atherectomy in patients with severely calcified ULMCA disease is feasible, even in high-risk patients who were considered poor surgical candidates. Randomized trials are needed to determine the role of orbital atherectomy in ULMCA disease.

  20. Lumen and calcium characteristics within calcified coronary lesions. Comparison of computed tomography coronary angiography versus intravascular ultrasound.

    Science.gov (United States)

    Noll, Dariusz; Kruk, Mariusz; Pręgowski, Jerzy; Kaczmarska, Edyta; Kryczka, Karolina; Pracoń, Radosław; Skwarek, Mirosław; Dzielińska, Zofia; Petryka, Joanna; Spiewak, Mateusz; Lubiszewska, Barbara; Norwa-Otto, Bożena; Opolski, Maksymilian; Witkowski, Adam; Demkow, Marcin; Rużyłło, Witold; Kępka, Cezary

    2013-01-01

    Computed tomography coronary angiography (CTCA) is a diagnostic method used for exclusion of coronary artery disease. However, lower accuracy of CTCA in assessment of calcified lesions is a significant factor impeding applicability of CTCA for assessment of coronary atherosclerosis. To provide insight into lumen and calcium characteristics assessed with CTCA, we compared these parameters to the reference of intravascular ultrasound (IVUS). Two hundred and fifty-two calcified lesions within 97 arteries of 60 patients (19 women, age 63 ±10 years) underwent assessment with both 2 × 64 slice CT (Somatom Definition, Siemens) and IVUS (s5, Volcano Corp.). Coronary lumen and calcium dimensions within calcified lesions were assessed with CTCA and compared to the reference measurements made with IVUS. On average CTCA underestimated mean lumen diameter (2.8 ±0.7 mm vs. 2.9 ±0.8 mm for IVUS), lumen area (6.4 ±3.4 mm(2) vs. 7.0 ±3.7 mm(2) for IVUS, p < 0.001) and total calcium arc (52 ±35° vs. 83 ±54°). However, analysis of tertiles of the examined parameters revealed that the mean lumen diameter, lumen area and calcium arc did not significantly differ between CTCA and IVUS within the smallest lumens (1(st) tertile of mean lumen diameter at 2.1 mm, and 1(st) tertile of lumen area at 3.7 mm(2)) and lowest calcium arc (mean of 40°). Although, on average, CTCA underestimates lumen diameter and area as well as calcium arc within calcified lesions, the differences are not significant within the smallest vessels and calcium arcs. The low diagnostic accuracy of CTCA within calcified lesions may be attributed to high variance and not to systematic error of measurements.

  1. High-speed scanning ablation of dental hard tissues with a λ = 9.3 μm CO2 laser: adhesion, mechanical strength, heat accumulation, and peripheral thermal damage

    OpenAIRE

    Nguyen, Daniel; Chang, Kwang; Hedayatollahnajafi, Saba; Staninec, Michal; Chan, Kenneth; Lee, Robert; Fried, Daniel

    2011-01-01

    CO2 lasers can be operated at high laser pulse repetition rates for the rapid and precise removal of dental decay. Excessive heat accumulation and peripheral thermal damage is a concern when using high pulse repetition rates. Peripheral thermal damage can adversely impact the mechanical strength of the irradiated tissue, particularly for dentin, and reduce the adhesion characteristics of the modified surfaces. The interpulpal temperature rise was recorded using microthermocouples situated at ...

  2. Biofabrication of soft tissue templates for engineering the bone-ligament interface.

    Science.gov (United States)

    Harris, Ella; Liu, Yurong; Cunniffe, Grainne; Morrissey, David; Carroll, Simon; Mulhall, Kevin; Kelly, Daniel J

    2017-10-01

    Regenerating damaged tissue interfaces remains a significant clinical challenge, requiring recapitulation of the structure, composition, and function of the native enthesis. In the ligament-to-bone interface, this region transitions from ligament to fibrocartilage, to calcified cartilage and then to bone. This gradation in tissue types facilitates the transfer of load between soft and hard structures while minimizing stress concentrations at the interface. Previous attempts to engineer the ligament-bone interface have utilized various scaffold materials with an array of various cell types and/or biological cues. The primary goal of this study was to engineer a multiphased construct mimicking the ligament-bone interface by driving differentiation of a single population of mesenchymal stem cells (MSCs), seeded within blended fibrin-alginate hydrogels, down an endochondral, fibrocartilaginous, or ligamentous pathway through spatial presentation of growth factors along the length of the construct within a custom-developed, dual-chamber culture system. MSCs within these engineered constructs demonstrated spatially distinct regions of differentiation, adopting either a cartilaginous or ligamentous phenotype depending on their local environment. Furthermore, there was also evidence of spatially defined progression toward an endochondral phenotype when chondrogenically primed MSCs within this construct were additionally exposed to hypertrophic cues. The study demonstrates the feasibility of engineering spatially complex soft tissues within a single MSC laden hydrogel through the defined presentation of biochemical cues. This novel approach represents a new strategy for engineering the ligament-bone interface. Biotechnol. Bioeng. 2017;114: 2400-2411. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  3. Fiscal 1998 regional consortium R and D project (Regional consortium field). Report on R and D of production technology of hybrid-type biocompatible hard tissue replacing materials (1st fiscal year); 1998 nendo chiiki konsoshiamu kenkyu kaihatsu jigyo. Chiiki konsoshiamu bun'ya (hybrid gata seitai yugo kinosei kososhiki daitai sozai seizo gijutsu no kenkyu kaihatsu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    This project aims at development of high-strength high- biocompatible {beta}-type Ti alloy with lower modulli of elasticity composed of non-toxic elements, phosphate calcium ceramics for improving the biocompatibility and coating technology, and establishment of production technology of hybrid-type biocompatible hard tissue replacing materials. In fiscal 1998, the project promoted the following: Design of high-biocompatible {beta}-type Ti alloy materials, development of thermomechanical treatment for improving dynamic characteristics of such alloy, survey on practical melting and casting technologies and dental precision casting process, evaluation of the biocompatibility of the alloy by cytotoxicity, selection of tools for precision machining and surface finishing, control of contents, orientation and precipitation of biocompatible crystals such as {beta}- Ca(PO{sub 3}){sub 2} fibers for further improvement of the biocompatibility. This paper also outlines the survey results on the market needs, market size and market share for the feasibility of these materials. (NEDO)

  4. Immediate versus Delayed Treatment in the Anterior Maxilla Using Single Implants with a Laser-Microtextured Collar: 3-Year Results of a Case Series on Hard- and Soft-Tissue Response and Esthetics.

    Science.gov (United States)

    Guarnieri, Renzo; Belleggia, Fabrizio; Grande, Maurizio

    2016-02-01

    To compare peri-implant marginal bone loss, soft tissue response, and esthetics following single immediate implant treatment (IIT) and delayed implant treatment (DIT) in the esthetic zone of the maxilla in well-selected patients. Adequate bone volume and ideal soft tissue level/contour were considered requirements for implant therapy, with additional prerequisites for IIT of residual alveolar bone wall integrity and a thick gingival biotype. IIT included immediate placement and provisionalization, while DIT included extraction socket preservation followed by implant placement and provisionalization 4 months later. Cortical bone levels and peri-implant mucosal conditions were evaluated at regular intervals. The esthetic outcome was objectively rated after 3 years using the pink esthetic score (PES) and white esthetic score (WES). Twelve patients received an immediate Laser-Lok® implant, and 13 patients received a delayed Laser-Lok® implant. No significant differences were found between the study groups regarding survival rate (100%). The mean bone level from the implant/abutment interface was 0.35 ± 0.18 mm for IIT and 0.42 ± 0.21 mm for DIT after 3 years (p > 0.05). Mesial and distal papillae remained stable over time in DIT. A tendency for regrowth of mesial and distal papillae was found following IIT (p esthetics, DIT and IIT with single Laser-Lok® implants in the anterior maxilla are comparable and predictable options for well-selected patients. © 2015 by the American College of Prosthodontists.

  5. Cooperation of Rho family proteins Rac1 and Cdc42 in cartilage development and calcified tissue formation.

    Science.gov (United States)

    Ikehata, Mikiko; Yamada, Atsushi; Fujita, Koji; Yoshida, Yuko; Kato, Tadashi; Sakashita, Akiko; Ogata, Hiroaki; Iijima, Takehiko; Kuroda, Masahiko; Chikazu, Daichi; Kamijo, Ryutaro

    2018-04-20

    Rac1 and Cdc42, Rho family low molecular weight G proteins, are intracellular signaling factors that transmit various information from outside to inside cells. Primarily, they are known to control various biological activities mediated by actin cytoskeleton reorganization, such as cell proliferation, differentiation, and apoptosis. In order to investigate the functions of Rac1 and Cdc42 in bone formation, we prepared cartilage-specific double conditional knockout mice, Rac1 fl/fl ; Cdc42 fl/fl ; Col2-Cre (Rac1: Cdc42 dcKO mice), which died just after birth, similar to Cdc42 fl/fl ; Col2-Cre mice (Cdc42 cKO mice). Our findings showed that the long tubule bone in Rac1: Cdc42 dcKO mice was shorter than that in Rac1 fl/fl ; Col2-Cre mice (Rac1 cKO mice) and Cdc42 cKO mice. Abnormal skeleton formation was also observed and disordered columnar formation in the growth plate of the Rac1: Cdc42 dcKO mice was more severe as compared to the Rac1 cKO and Cdc42 cKO mice. Together, these results suggest that Rac1 and Cdc42 have cooperating roles in regulation of bone development. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. International Osteoporosis Foundation and European Calcified Tissue Society Working Group. Recommendations for the screening of adherence to oral bisphosphonates

    DEFF Research Database (Denmark)

    Diez-Perez, Adolfo; Naylor, K E; Abrahamsen, B

    2017-01-01

    Adherence to oral bisphosphonates is low. A screening strategy is proposed based on the response of biochemical markers of bone turnover after 3 months of therapy. If no change is observed, the clinician should reassess the adherence to the treatment and also other potential issues with the drug....

  7. Movement of 125I albumin and 125I polyvinylpyrrolidone through bone tissue fluid

    International Nuclear Information System (INIS)

    Owen, M.; Howlett, C.R.; Triffitt, J.T.

    1977-01-01

    The passage of tissue fluid through cortical bone has been investigated using radioactively labelled macromolocules as markers. The results suggest that in the cortex of young rabbit femur the movement of tissue fluid is in the same net direction as blood, mainly from the endosteal to the periosteal surface. Some albumin is incorporated from extravascular tissue fluid into calcified matrix at sites of bone formation. Polyvinylpyrrolidone, average molecular weight 35,000, is able to pass through extravascular tissue fluid in bone but is not incorporated into calcified matrix. In rabbits made vitamin D deficient, much less albumin is retained in regions of bone formation than is the case with controls. Albumin adsorbs to the surface of calcium phosphate precipitates, and it is suggested that this mechanism may be mainly responsible for its incorporation into bone. (orig.) 891 AJ [de

  8. Revisiting the definition of local hardness and hardness kernel.

    Science.gov (United States)

    Polanco-Ramírez, Carlos A; Franco-Pérez, Marco; Carmona-Espíndola, Javier; Gázquez, José L; Ayers, Paul W

    2017-05-17

    An analysis of the hardness kernel and local hardness is performed to propose new definitions for these quantities that follow a similar pattern to the one that characterizes the quantities associated with softness, that is, we have derived new definitions for which the integral of the hardness kernel over the whole space of one of the variables leads to local hardness, and the integral of local hardness over the whole space leads to global hardness. A basic aspect of the present approach is that global hardness keeps its identity as the second derivative of energy with respect to the number of electrons. Local hardness thus obtained depends on the first and second derivatives of energy and electron density with respect to the number of electrons. When these derivatives are approximated by a smooth quadratic interpolation of energy, the expression for local hardness reduces to the one intuitively proposed by Meneses, Tiznado, Contreras and Fuentealba. However, when one combines the first directional derivatives with smooth second derivatives one finds additional terms that allow one to differentiate local hardness for electrophilic attack from the one for nucleophilic attack. Numerical results related to electrophilic attacks on substituted pyridines, substituted benzenes and substituted ethenes are presented to show the overall performance of the new definition.

  9. Impact of seawater acidification on pH at the tissue-skeleton interface and calcification in reef corals.

    Science.gov (United States)

    Venn, Alexander A; Tambutté, Eric; Holcomb, Michael; Laurent, Julien; Allemand, Denis; Tambutté, Sylvie

    2013-01-29

    Insight into the response of reef corals and other major marine calcifiers to ocean acidification is limited by a lack of knowledge about how seawater pH and carbonate chemistry impact the physiological processes that drive biomineralization. Ocean acidification is proposed to reduce calcification rates in corals by causing declines in internal pH at the calcifying tissue-skeleton interface where biomineralization takes place. Here, we performed an in vivo study on how partial-pressure CO(2)-driven seawater acidification impacts intracellular pH in coral calcifying cells and extracellular pH in the fluid at the tissue-skeleton interface [subcalicoblastic medium (SCM)] in the coral Stylophora pistillata. We also measured calcification in corals grown under the same conditions of seawater acidification by measuring lateral growth of colonies and growth of aragonite crystals under the calcifying tissue. Our findings confirm that seawater acidification decreases pH of the SCM, but this decrease is gradual relative to the surrounding seawater, leading to an increasing pH gradient between the SCM and seawater. Reductions in calcification rate, both at the level of crystals and whole colonies, were only observed in our lowest pH treatment when pH was significantly depressed in the calcifying cells in addition to the SCM. Overall, our findings suggest that reef corals may mitigate the effects of seawater acidification by regulating pH in the SCM, but they also highlight the role of calcifying cell pH homeostasis in determining the response of reef corals to changes in external seawater pH and carbonate chemistry.

  10. Report of Two Cases of Combined Odontogenic Tumors: Ameloblastoma with Odontogenic Keratocyst and Ameloblastic Fibroma with Calcifying Odontogenic Cyst.

    Science.gov (United States)

    Neuman, Ashley Nicole; Montague, Lindsay; Cohen, Donald; Islam, Nadim; Bhattacharyya, Indraneel

    2015-09-01

    Combined odontogenic neoplasms have rarely been documented. Such tumors have also been described by other researchers as "hybrid" lesions. The histologic features are often identical to other individually well-established odontogenic neoplasms such as ameloblastoma, adenomatoid odontogenic tumor, ameloblastic fibroma (AF), and ameloblastic fibro-odontoma. Their clinical presentation is variable, ranging from cysts to neoplasms showing varying degrees of aggressive behavior. Most combined tumors contain features of one of the odontogenic tumors in combination with either a calcifying odontogenic cyst (COC) or a calcifying epithelial odontogenic tumor. We present two new cases of combined odontogenic tumors: an ameloblastoma with an odontogenic keratocyst and an AF with COC. Predicting clinical outcome is challenging when a combination tumor is encountered due to the paucity of such lesions. One must understand salient features of these entities and differentiate them from the more common conventional neoplasms to expand classification and provide prognostic criteria.

  11. Lumen and calcium characteristics within calcified coronary lesions. Comparison of computed tomography coronary angiography versus intravascular ultrasound

    OpenAIRE

    Noll, Dariusz; Kruk, Mariusz; Pręgowski, Jerzy; Kaczmarska, Edyta; Kryczka, Karolina; Pracoń, Radosław; Skwarek, Mirosław; Dzielińska, Zofia; Petryka, Joanna; Śpiewak, Mateusz; Lubiszewska, Barbara; Norwa-Otto, Bożena; Opolski, Maksymilian; Witkowski, Adam; Demkow, Marcin

    2013-01-01

    Introduction Computed tomography coronary angiography (CTCA) is a diagnostic method used for exclusion of coronary artery disease. However, lower accuracy of CTCA in assessment of calcified lesions is a significant factor impeding applicability of CTCA for assessment of coronary atherosclerosis. Aim To provide insight into lumen and calcium characteristics assessed with CTCA, we compared these parameters to the reference of intravascular ultrasound (IVUS). Material and methods Two hundred and...

  12. Combined nanoindentation testing and scanning electron microscopy of bone and articular calcified cartilage in an equine fracture predilection site

    OpenAIRE

    M Doube; EC Firth; A Boyde; AJ Bushby

    2010-01-01

    Condylar fracture of the third metacarpal bone (Mc3) is the commonest cause of racetrack fatality in Thoroughbred horses. Linear defects involving hyaline articular cartilage, articular calcified cartilage (ACC) and subchondral bone (SCB) have been associated with the fracture initiation site, which lies in the sagittal grooves of the Mc3 condyle. We discovered areas of thickened and abnormally-mineralised ACC in the sagittal grooves of several normal 18-month-old horses, at the same site tha...

  13. Hard and Soft Governance

    DEFF Research Database (Denmark)

    Moos, Lejf

    2009-01-01

    of Denmark, and finally the third layer: the leadership used in Danish schools. The use of 'soft governance' is shifting the focus of governance and leadership from decisions towards influence and power and thus shifting the focus of the processes from the decision-making itself towards more focus......The governance and leadership at transnational, national and school level seem to be converging into a number of isomorphic forms as we see a tendency towards substituting 'hard' forms of governance, that are legally binding, with 'soft' forms based on persuasion and advice. This article analyses...... and discusses governance forms at several levels. The first layer is the global: the methods of 'soft governance' that are being utilised by transnational agencies. The second layer is the national and local: the shift in national and local governance seen in many countries, but here demonstrated in the case...

  14. Zirconium nitride hard coatings

    International Nuclear Information System (INIS)

    Roman, Daiane; Amorim, Cintia Lugnani Gomes de; Soares, Gabriel Vieira; Figueroa, Carlos Alejandro; Baumvol, Israel Jacob Rabin; Basso, Rodrigo Leonardo de Oliveira

    2010-01-01

    Zirconium nitride (ZrN) nanometric films were deposited onto different substrates, in order to study the surface crystalline microstructure and also to investigate the electrochemical behavior to obtain a better composition that minimizes corrosion reactions. The coatings were produced by physical vapor deposition (PVD). The influence of the nitrogen partial pressure, deposition time and temperature over the surface properties was studied. Rutherford backscattering spectrometry (RBS), X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD), scanning electron microscopy (SEM) and corrosion experiments were performed to characterize the ZrN hard coatings. The ZrN films properties and microstructure changes according to the deposition parameters. The corrosion resistance increases with temperature used in the films deposition. Corrosion tests show that ZrN coating deposited by PVD onto titanium substrate can improve the corrosion resistance. (author)

  15. Calcified carotid atherosclerotic plaques on digital panoramic radiographs in patients with Type II diabetes mellitus: A case control study

    Directory of Open Access Journals (Sweden)

    Neha Khambete

    2015-01-01

    Full Text Available Aim: Diabetes mellitus is associated with accelerated carotid artery atherosclerosis and increased risk of stroke. This study was conducted with the objective of determining the prevalence of calcified atherosclerotic plaques on panoramic radiographs of patients with Type II diabetes mellitus. Materials and Methods: Panoramic radiographs of 100 patients (age range 50-84 years with known history of type II diabetes mellitus, visiting the outpatient department were evaluated for the presence of calcified atherosclerotic plaques. Age- and sex-matched controls were evaluated in the same manner. Statistical comparison of prevalence rates was done. Results: The radiographs of diabetics (mean age: 64.45 years revealed that 26% had atheromatous plaques, whereas those of controls (mean age: 65.36 years revealed that 6% had atheromatous plaques. A statistically significant difference (P = 0.01410 was obtained using Yates′ Chi-square test. Conclusion: People with diabetes mellitus had a greater prevalence of calcified atherosclerotic plaques on panoramic radiographs than non-diabetics. Panoramic radiographs of diabetic patients should be screened for the presence of carotid artery atheromatous plaques for timely medical referral of asymptomatic patients and avoiding any further serious consequences like cerebrovascular accidents.

  16. High-energy extracorporeal shock-wave therapy for calcifying tendinitis of the rotator cuff: a randomised trial.

    Science.gov (United States)

    Albert, J-D; Meadeb, J; Guggenbuhl, P; Marin, F; Benkalfate, T; Thomazeau, H; Chalès, G

    2007-03-01

    In a prospective randomised trial of calcifying tendinitis of the rotator cuff, we compared the efficacy of dual treatment sessions delivering 2500 extracorporeal shock waves at either high- or low-energy, via an electromagnetic generator under fluoroscopic guidance. Patients were eligible for the study if they had more than a three-month history of calcifying tendinitis of the rotator cuff, with calcification measuring 10 mm or more in maximum dimension. The primary outcome measure was the change in the Constant and Murley Score. A total of 80 patients were enrolled (40 in each group), and were re-evaluated at a mean of 110 (41 to 255) days after treatment when the increase in Constant and Murley score was significantly greater (t-test, p = 0.026) in the high-energy treatment group than in the low-energy group. The improvement from the baseline level was significant in the high-energy group, with a mean gain of 12.5 (-20.7 to 47.5) points (p energy group. Total or subtotal resorption of the calcification occurred in six patients (15%) in the high-energy group and in two patients (5%) in the low-energy group. High-energy shock-wave therapy significantly improves symptoms in refractory calcifying tendinitis of the shoulder after three months of follow-up, but the calcific deposit remains unchanged in size in the majority of patients.

  17. Increasing costs due to ocean acidification drives phytoplankton to be more heavily calcified: optimal growth strategy of coccolithophores.

    Directory of Open Access Journals (Sweden)

    Takahiro Irie

    Full Text Available Ocean acidification is potentially one of the greatest threats to marine ecosystems and global carbon cycling. Amongst calcifying organisms, coccolithophores have received special attention because their calcite precipitation plays a significant role in alkalinity flux to the deep ocean (i.e., inorganic carbon pump. Currently, empirical effort is devoted to evaluating the plastic responses to acidification, but evolutionary considerations are missing from this approach. We thus constructed an optimality model to evaluate the evolutionary response of coccolithophorid life history, assuming that their exoskeleton (coccolith serves to reduce the instantaneous mortality rates. Our model predicted that natural selection favors constructing more heavily calcified exoskeleton in response to increased acidification-driven costs. This counter-intuitive response occurs because the fitness benefit of choosing a better-defended, slower growth strategy in more acidic conditions, outweighs that of accelerating the cell cycle, as this occurs by producing less calcified exoskeleton. Contrary to the widely held belief, the evolutionarily optimized population can precipitate larger amounts of CaCO(3 during the bloom in more acidified seawater, depending on parameter values. These findings suggest that ocean acidification may enhance the calcification rates of marine organisms as an adaptive response, possibly accompanied by higher carbon fixation ability. Our theory also provides a compelling explanation for the multispecific fossil time-series record from ∼200 years ago to present, in which mean coccolith size has increased along with rising atmospheric CO(2 concentration.

  18. Coral calcifying fluid pH is modulated by seawater carbonate chemistry not solely seawater pH.

    Science.gov (United States)

    Comeau, S; Tambutté, E; Carpenter, R C; Edmunds, P J; Evensen, N R; Allemand, D; Ferrier-Pagès, C; Tambutté, S; Venn, A A

    2017-01-25

    Reef coral calcification depends on regulation of pH in the internal calcifying fluid (CF) in which the coral skeleton forms. However, little is known about calcifying fluid pH (pH CF ) regulation, despite its importance in determining the response of corals to ocean acidification. Here, we investigate pH CF in the coral Stylophora pistillata in seawater maintained at constant pH with manipulated carbonate chemistry to alter dissolved inorganic carbon (DIC) concentration, and therefore total alkalinity (A T ). We also investigate the intracellular pH of calcifying cells, photosynthesis, respiration and calcification rates under the same conditions. Our results show that despite constant pH in the surrounding seawater, pH CF is sensitive to shifts in carbonate chemistry associated with changes in [DIC] and [A T ], revealing that seawater pH is not the sole driver of pH CF Notably, when we synthesize our results with published data, we identify linear relationships of pH CF with the seawater [DIC]/[H + ] ratio, [A T ]/ [H + ] ratio and [[Formula: see text

  19. Coincidence of calcified carotid atheromatous plaque, osteoporosis, and periodontal bone loss in dental panoramic radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Ramesh, Aruna; Ganguly, Rumpa [Dept. of Diagnosis and Health Promotion, Division of Oral and Maxillofacial Radiology, Tufts University School of Dental Medicine, Boston (United States); Soroushian, Sheila [Dept. of Orthodontics, Howard University College of Dentistry, Washington, DC(United States)

    2013-12-15

    This study was performed to assess the correlation of calcified carotid atheromatous plaque (CCAP), the mandibular cortical index, and periodontal bone loss in panoramic radiographs. One hundred eighty-five panoramic radiographs with CCAP and 234 without this finding were evaluated by 3 observers for the presence of osseous changes related to osteoporosis and periodontal bone loss. Chi-squared and Mann-Whitney U tests were used to compare the two groups for an association of CCAP with the mandibular cortical index and periodontal bone loss, respectively. There was a statistically significant coincidence of CCAP and osseous changes related to osteopenia/osteoporosis, with a p-value <0.001. There was no statistically significant coincidence of CCAP and periodontal bone loss. When comparing the 2 groups, 'With CCAP' and 'Without CCAP', there was a statistically significant association with the mean body mass index (BMI), number of remaining teeth, positive history of diabetes mellitus, and vascular accidents. There was no statistically significant association with gender or a history of smoking. This study identified a possible concurrence of CCAP and mandibular cortical changes secondary to osteopenia/osteoporosis in panoramic radiographs. This could demonstrate the important role of dental professionals in screening for these systemic conditions, leading to timely and appropriate referrals resulting in early interventions and thus improving overall health.

  20. First report of MRI findings in a case of an autoamputated wandering calcified ovary

    Directory of Open Access Journals (Sweden)

    Mahajan PS

    2014-03-01

    Full Text Available Parag Suresh Mahajan, Nazeer Ahamad, Sheik Akbar Hussain Department of Radiology, Al-Khor Hospital, Hamad Medical Corporation, Doha, Qatar Abstract: An autoamputated wandering calcified ovary (AWCO is an extremely rare cause of abdominal calcification in the pediatric population. We present the magnetic resonance imaging (MRI features of AWCO in a child. To our knowledge, the MRI features of AWCO have not been previously described in the published literature. Our case report indicates that the MRI findings are characteristic in the diagnosis of an AWCO and can completely obviate the need for invasive procedures in this mostly benign disease. An AWCO should be considered in all cases of mobile calcific opacities on radiographs in female patients. We advise that MRI be conducted in all suspected cases of AWCO for accurate and noninvasive diagnosis, and regular follow-up should be performed with ultrasound. The findings in our case report have the potential to change the course of investigations and management in suspected cases. Keywords: magnetic resonance imaging, ovary, adnexa, autoamputation, wandering calcification

  1. Coincidence of calcified carotid atheromatous plaque, osteoporosis, and periodontal bone loss in dental panoramic radiographs

    International Nuclear Information System (INIS)

    Ramesh, Aruna; Ganguly, Rumpa; Soroushian, Sheila

    2013-01-01

    This study was performed to assess the correlation of calcified carotid atheromatous plaque (CCAP), the mandibular cortical index, and periodontal bone loss in panoramic radiographs. One hundred eighty-five panoramic radiographs with CCAP and 234 without this finding were evaluated by 3 observers for the presence of osseous changes related to osteoporosis and periodontal bone loss. Chi-squared and Mann-Whitney U tests were used to compare the two groups for an association of CCAP with the mandibular cortical index and periodontal bone loss, respectively. There was a statistically significant coincidence of CCAP and osseous changes related to osteopenia/osteoporosis, with a p-value <0.001. There was no statistically significant coincidence of CCAP and periodontal bone loss. When comparing the 2 groups, 'With CCAP' and 'Without CCAP', there was a statistically significant association with the mean body mass index (BMI), number of remaining teeth, positive history of diabetes mellitus, and vascular accidents. There was no statistically significant association with gender or a history of smoking. This study identified a possible concurrence of CCAP and mandibular cortical changes secondary to osteopenia/osteoporosis in panoramic radiographs. This could demonstrate the important role of dental professionals in screening for these systemic conditions, leading to timely and appropriate referrals resulting in early interventions and thus improving overall health.

  2. TAVR Through Heavily Calcified Aorta Following Atheroma Retrieval With the "Elevator" Technique.

    Science.gov (United States)

    Senguttuvan, N Boopathy; Ellozy, Sharif; Tejani, Furqan; Kovacic, Jason; Kini, Annapoorna S; Sharma, Samin K; Dangas, George D

    2015-10-01

    An 86-year-old Caucasian female with severe symptomatic, inoperable aortic stenosis was accepted for high-risk transfemoral transcatheter aortic valve replacement (TAVR) approach due to severe calcification of the aorta. During initial passage of a 22 Fr sheath, there was dislodgment with proximal migration of a circumferential tunnel of calcium from the infrarenal aorta. A novel "elevator" technique was used to secure and retrieve the dislodged aorta en bloc back to its original infrarenal aortic position and allow in situ fixation with stenting. A new TAVR system was then successfully placed through the stent and a 23 mm Edwards Sapien valve (Edwards Lifesciences) was implanted as planned. In case of calcification protruding into the lumen of the aorta and limiting the passage of the large valve delivery system sheath, the obstruction can be managed by stenting the calcification against the luminal wall under fluoroscopic and intravascular-ultrasound guidance, allowing successful passage of the valve delivery system. The elevator technique allows axial transportation of any calcified vascular fragments, should they become dislodged.

  3. Non-calcified coronary plaque volume inversely related to CD4 count in HIV infection

    Science.gov (United States)

    Duarte, Horacio; Matta, Jatin R.; Muldoon, Nancy; Masur, Henry; Hadigan, Colleen; Gharib, Ahmed M.

    2013-01-01

    Background Non-calcified coronary artery plaque (NCAP) may be an important predictor of cardiovascular events, however, few studies have directly measured NCAP in HIV-infected individuals. Methods We completed a prospective cross-sectional evaluation of NCAP and coronary calcium scores using CT angiography in HIV-infected subjects (n=26) without known coronary artery disease (CAD), but who had one or more CAD risk factor and compared them to controls matched on age, race, sex, body mass index and Framingham risk score (n=26). Results There was no difference in coronary calcium scores (114 ± 218 vs. 124 ± 298 p=0.89) or NCAP volume (65 ± 86 mm3 vs. 63 ± 82 mm3, p=0.38) between HIV-infected subjects and controls, respectively. Among HIV-infected subjects, lower CD4 count was associated with increased NCAP volume (r=-0.52, p=0.006). CD4 count remained a significant predictor of NCAP in a multivariate analysis that adjusted for age and duration of antiretroviral therapy. Conclusion Plaque burden is similar between HIV-infected and uninfected individuals when matched on traditional CAD risk factors, however immune function may mediate the development of atherosclerosis in HIV infection. PMID:22293714

  4. The response of calcifying plankton to climate change in the Pliocene

    Directory of Open Access Journals (Sweden)

    C. V. Davis

    2013-09-01

    Full Text Available As a result of anthropogenic pCO2 increases, future oceans are growing warmer and lower in pH and oxygen, conditions that are likely to impact planktic communities. Past intervals of elevated and changing pCO2 and temperatures can offer a glimpse into the response of marine calcifying plankton to changes in surface oceans under conditions similar to those projected for the future. Here we present new records of planktic foraminiferal and coccolith calcification (weight and size from Deep Sea Drilling Project Site 607 (mid-North Atlantic and Ocean Drilling Program Site 999 (Caribbean Sea from the Pliocene, the last time that pCO2 was similar to today, and extending through a global cooling event into the intensification of Northern Hemisphere glaciation (3.3 to 2.6 million years ago. Test weights of both surface-dwelling Foraminifera Globigerina bulloides and thermocline-dwelling Foraminifera Globorotalia puncticulata vary with a potential link to regional temperature variation in the North Atlantic, whereas in the tropics Globigerinoides ruber test weight remains stable. In contrast, reticulofenestrid coccoliths show a narrowing size range and a decline in the largest lith diameters over this interval. Our results suggest no major changes in plankton calcite production during the high pCO2 Pliocene or during the transition into an icehouse world.

  5. The clinical and radiological consideration of calcifying odontogenic cyst of the jaw

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Hae Rym; Kim, Kee Deog; Park, Chang Seo [Dept. of Dental radiology, College of Dentistry, Yensei University, (Korea, Republic of)

    1996-08-15

    Nine cases presented with a calcifying odontogenic cyst to the Dental Hospital of the College of Dentistry, Yonsei University, from January 1987 to September June, 1996, Clinical or histopathological findings were observed according to each radiologic criteria. The results obtained are as follows:1. The male to female ratio was 2 : 1 with a mean age of 25 years. 2. The radiographic appearances of nine caes were well-defined radiolucent lesions in which eight cases were shown until ocular lesions and only one lesion was seen multilocular lesion. 3. Radiologically, three of nine cases were pure radiolucent lesion and others, six cases were radiolucent contained a variable amount of radiopaque material. 4. Histologically, two cases were classified simple cyst, five were cyst associated odontoma, two were neoplastic type. 5. Histological findings according to the radiological classification, two of three radiolucent lesions were simple cys ts; another was a cyst associated with odontoma. While, four of six radiologic mixed lesions turned out to be a cyst associated with odontoma, two was the neoplastic type.

  6. Computing the carbonate chemistry of the coral calcifying medium and its response to ocean acidification.

    Science.gov (United States)

    Raybaud, Virginie; Tambutté, Sylvie; Ferrier-Pagès, Christine; Reynaud, Stéphanie; Venn, Alexander A; Tambutté, Éric; Nival, Paul; Allemand, Denis

    2017-07-07

    Critical to determining vulnerability or resilience of reef corals to Ocean Acidification (OA) is a clearer understanding of the extent to which corals can control carbonate chemistry in their Extracellular Calcifying Medium (ECM) where the CaCO 3 skeleton is produced. Here, we employ a mathematical framework to calculate ECM aragonite saturation state (Ω arag.(ECM) ) and carbonate system ion concentration using measurements of calcification rate, seawater characteristics (temperature, salinity and pH) and ECM pH (pH (ECM) ). Our calculations of ECM carbonate chemistry at current-day seawater pH, indicate that Ω arag.(ECM) ranges from ∼10 to 38 (mean 20.41), i.e. about 5 to 6-fold higher than seawater. Accordingly, Dissolved Inorganic Carbon (DIC) and Total Alkalinity (TA) were calculated to be around 3 times higher in the ECM than in seawater. We also assessed the effects of acidification on ECM chemical properties of the coral Stylophora pistillata. At reduced seawater pH our calculations indicate that Ω arag.(ECM) remains almost constant. DIC (ECM) and TA (ECM) gradually increase as seawater pH declines, reaching values about 5 to 6-fold higher than in seawater, respectively for DIC and TA. We propose that these ECM characteristics buffer the effect of acidification and explain why certain corals continue to produce CaCO 3 even when seawater chemistry is less favourable. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Using algae and submerged calcifying water flora for treating neutral to alkaline uranium-contaminated water

    International Nuclear Information System (INIS)

    Dienemann, C.; Dienemann, H.; Stolz, L.; Dudel, E.G.

    2005-01-01

    Elimination of uranium from neutral to alkaline water is a complex technical process involving decarbonation, usually with HCl, followed by uranium removal by adding alkaline substances. In passive water treatment systems, uranium species - which often consist of a combination of oxidation and reduction stages - are not sufficiently considered. Algae and submerged water plants provide a natural alternative. They remove carbon dioxides or hydrogen carbonate, depending on the species, thus reducting the concentrations of the carbonate species. As the uranium species in alkaline water are coupled on the one hand to the carbonate species and on the other hand on the earth alkali metals, algae and submerged calcifying water plants are an excellent preliminary stage as a supplement to conventional passive water treatment systems. For a quantification of this effect, laboratory experiments were made with Cladophara spec. and with uranium concentrations of 100, 250 and 1000 μg U.L -1 at pH 8.3. The pH was adjusted with NaOH resp. Na2CO3 resulting in different uranium species. After 20 minutes, there was a difference in self-absorption between the different species (higher uranium concentration for NaOH than for Na2CO3), which was no longer observeable after 24 h. On the basis of data on the biomass development of macrophytic algae (Cladophora and Microspora) in a flowing river section near Neuensalz/Vogtland district, the final dimensions of a purification stage of this type are assessed. (orig.)

  8. An interesting finding in the uterine cervix: Schistosoma hematobium calcified eggs.

    Science.gov (United States)

    Toller, Alexia; Scopin, Ana Carolina; Apfel, Vanessa; Prigenzi, Karla Calaça Kabbach; Tso, Fernanda Kesselring; Focchi, Gustavo Rubino de Azevedo; Speck, Neila; Ribalta, Julisa

    2015-01-01

    Schistosoma hematobium infection is an endemic parasitic disease in Africa, which is frequently associated with urinary schistosomiasis. The parasite infection causes epithelial changes and disruption, facilitating the infection by the human papilloma virus and human immunodeficiency virus (HIV). The authors report the case of a 44-year-old African HIV-positive woman who presented an abnormal routine Pap smear. Colposcopy examination revealed dense acetowhite micropapillary epithelium covering the ectocervix, iodine-negative, an erosion area in endocervical canal, and atypical vessels. Histologic examination of the surgical specimens showed numerous calcified schistosome eggs (probably S. hematobium) and a high-grade cervical intraepithelial neoplasia. The relation between S. hematobium infection and bladder cancer is well known; however, this relationship with cervical cancer remains controversial. The symptoms of schistosomiasis of the female genital tract are rather non-specific, and are often misdiagnosed with other pelvic diseases. The familiarity of health professionals with schistosomiasis of the female genital tract is less than expected, even in endemic regions. Therefore, great awareness of this differential diagnosis in routine gynecological practice is of paramount importance.

  9. Community-level sensitivity of a calcifying ecosystem to acute in situ CO2 enrichment

    KAUST Repository

    Burdett, HL

    2017-11-23

    The rate of change in ocean carbonate chemistry is a vital determinant in the magnitude of effects observed. Benthic marine ecosystems are facing an increasing risk of acute CO2 exposure that may be natural or anthropogenically derived (e.g. engineering and industrial activities). However, our understanding of how acute CO2 events impact marine life is restricted to individual organisms, with little understanding for how this manifests at the community level. Here, we investigated in situ the effect of acute CO2 enrichment on the coralline algal ecosystem—a globally ubiquitous, ecologically and economically important habitat, but one which is likely to be sensitive to CO2 enrichment due to its highly calcified reef-like structures engineered by coralline algae. Most notably, we observed a rapid community-level shift to favour net dissolution rather than net calcification. Smaller changes from net respiration to net photosynthesis were also observed. There was no effect on the net flux of DMS/DMSP (algal secondary metabolites), nor on the nutrients nitrate and phosphate. Following return to ambient CO2 levels, only a partial recovery was seen within the monitoring timeframe. This study highlights the sensitivity of biogenic carbonate marine communities to acute CO2 enrichment and raises concerns over the capacity for the system to ‘bounce back’ if subjected to repeated acute high-CO2 events.

  10. Cartilage damage involving extrusion of mineralisable matrix from the articular calcified cartilage and subchondral bone

    Directory of Open Access Journals (Sweden)

    A Boyde

    2011-05-01

    Full Text Available Arthropathy of the distal articular surfaces of the third metacarpal (Mc3 and metatarsal (Mt3 bones in the Thoroughbred racehorse (Tb is a natural model of repetitive overload arthrosis. We describe a novel pathology that affects the articular calcified cartilage (ACC and subchondral bone (SCB and which is associated with hyaline articular cartilage degeneration. Parasagittal slices cut from the palmar quadrant of the distal condyles of the left Mc3/Mt3 of 39 trained Tbs euthanased for welfare reasons were imaged by point projection microradiography, and backscattered electron (BSE scanning electron microscopy (SEM, light microscopy, and confocal scanning light microscopy. Mechanical properties were studied by nanoindentation. Data on the horses' training and racing career were also collected. Highly mineralised projections were observed extending from cracks in the ACC mineralising front into the hyaline articular cartilage (HAC up to two-thirds the thickness of the HAC, and were associated with focal HAC surface fibrillation directly overlying their site. Nanoindentation identified this extruded matrix to be stiffer than any other mineralised phase in the specimen by a factor of two. The presence of projections was associated with a higher cartilage Mankin histology score (P < 0.02 and increased amounts of gross cartilage loss pathologically on the condyle (P < 0.02. Presence of projections was not significantly associated with: total number of racing seasons, age of horse, amount of earnings, number of days in training, total distance galloped in career, or presence of wear lines.

  11. Acute neck pain caused by pseudogout attack of calcified cervical yellow ligament: a case report.

    Science.gov (United States)

    Kobayashi, Takashi; Miyakoshi, Naohisa; Abe, Toshiki; Abe, Eiji; Kikuchi, Kazuma; Noguchi, Hideaki; Konno, Norikazu; Shimada, Yoichi

    2016-05-30

    Calcification of the yellow ligament sometimes compresses the spinal cord and can induce myelopathy. Usually, the calcification does not induce acute neck pain. We report a case of a patient with acute neck pain caused by calcium pyrophosphate dihydrate in a calcified cervical yellow ligament. A 70-year-old Japanese woman presented with acute neck pain. She had a moderately high fever (37.5 °C), and her neck pain was so severe that she could not move her neck in any direction. Computed tomography showed a high-density area between the C5 and C6 laminae suspicious for calcification of the yellow ligament. Magnetic resonance imaging showed intermediate-signal intensity on T1-weighted imaging and high-signal intensity on T2-weighted imaging surrounding a low-signal region on both T1- and T2-weighted imaging with cord compression. There was a turbid, yellow fluid collection in the yellow ligament at the time of operation. Histologically, calcium pyrophosphate dihydrate crystals were found in the fluid, and she was diagnosed as having a pseudogout attack of the yellow ligament. Pseudogout attack of the cervical yellow ligament is rare, but this clinical entity should be added to the differential diagnosis of acute neck pain, especially when calcification of the yellow ligament exists.

  12. Janka hardness using nonstandard specimens

    Science.gov (United States)

    David W. Green; Marshall Begel; William Nelson

    2006-01-01

    Janka hardness determined on 1.5- by 3.5-in. specimens (2×4s) was found to be equivalent to that determined using the 2- by 2-in. specimen specified in ASTM D 143. Data are presented on the relationship between Janka hardness and the strength of clear wood. Analysis of historical data determined using standard specimens indicated no difference between side hardness...

  13. 2TB hard disk drive

    CERN Multimedia

    This particular object was used up until 2012 in the Data Centre. It slots into one of the Disk Server trays. Hard disks were invented in the 1950s. They started as large disks up to 20 inches in diameter holding just a few megabytes (link is external). They were originally called "fixed disks" or "Winchesters" (a code name used for a popular IBM product). They later became known as "hard disks" to distinguish them from "floppy disks (link is external)." Hard disks have a hard platter that holds the magnetic medium, as opposed to the flexible plastic film found in tapes and floppies.

  14. High-speed scanning ablation of dental hard tissues with a λ = 9.3 μm CO2 laser: adhesion, mechanical strength, heat accumulation, and peripheral thermal damage

    Science.gov (United States)

    Nguyen, Daniel; Chang, Kwang; Hedayatollahnajafi, Saba; Staninec, Michal; Chan, Kenneth; Lee, Robert; Fried, Daniel

    2011-07-01

    CO2 lasers can be operated at high laser pulse repetition rates for the rapid and precise removal of dental decay. Excessive heat accumulation and peripheral thermal damage is a concern when using high pulse repetition rates. Peripheral thermal damage can adversely impact the mechanical strength of the irradiated tissue, particularly for dentin, and reduce the adhesion characteristics of the modified surfaces. The interpulpal temperature rise was recorded using microthermocouples situated at the roof of the pulp chamber on teeth that were occlusally ablated using a rapidly-scanned CO2 laser operating at 9.3 μm with a pulse duration of 10 to 15 μs and repetition rate of 300 Hz over a 2 min time course. The adhesion strength of laser treated enamel and dentin surfaces was measured for various laser scanning parameters with and without post-ablation acid etching using the single-plane shear test. The mechanical strength of laser-ablated dentin surfaces were determined via the four-point bend test and compared to control samples prepared with 320 grit wet sand paper to simulate conventional preparations. Thermocouple measurements indicated that the temperature remained below ambient temperature if water-cooling was used. There was no discoloration of either dentin or enamel laser treated surfaces, the surfaces were uniformly ablated, and there were no cracks visible. Four-point bend tests yielded mean mechanical strengths of 18.2 N (s.d. = 4.6) for ablated dentin and 18.1 N (s.d. = 2.7) for control (p > 0.05). Shear tests yielded mean bond strengths approaching 30 MPa for both enamel and dentin under certain irradiation conditions. These values were slightly lower than nonirradiated acid-etched control samples. Additional studies are needed to determine if the slightly lower bond strength than the acid-etched control samples is clinically significant. These measurements demonstrate that enamel and dentin surfaces can be rapidly ablated by CO2 lasers with minimal

  15. Hard processes. Vol. 1

    International Nuclear Information System (INIS)

    Ioffe, B.L.; Khoze, V.A.; Lipatov, L.N.

    1984-01-01

    Deep inelastic (hard) processes are now at the epicenter of modern high-energy physics. These processes are governed by short-distance dynamics, which reveals the intrinsic structure of elementary particles. The theory of deep inelastic processes is now sufficiently well settled. The authors' aim was to give an effective tool to theoreticians and experimentalists who are engaged in high-energy physics. This book is intended primarily for physicists who are only beginning to study the field. To read the book, one should be acquainted with the Feynman diagram technique and with some particular topics from elementary particle theory (symmetries, dispersion relations, Regge pole theory, etc.). Theoretical consideration of deep inelastic processes is now based on quantum chromodynamics (QCD). At the same time, analysis of relevant physical phenomena demands a synthesis of QCD notions (quarks, gluons) with certain empirical characteristics. Therefore, the phenomenological approaches presented are a necessary stage in a study of this range of phenomena which should undoubtedly be followed by a detailed description based on QCD and electroweak theory. The authors were naturally unable to dwell on experimental data accumulated during the past decade of intensive investigations. Priority was given to results which allow a direct comparison with theoretical predictions. (Auth.)

  16. Hard coal; Steinkohle

    Energy Technology Data Exchange (ETDEWEB)

    Loo, Kai van de; Sitte, Andreas-Peter [Gesamtverband Steinkohle e.V. (GVSt), Herne (Germany)

    2015-07-01

    International the coal market in 2014 was the first time in a long time in a period of stagnation. In Germany, the coal consumption decreased even significantly, mainly due to the decrease in power generation. Here the national energy transition has now been noticable affected negative for coal use. The political guidances can expect a further significant downward movement for the future. In the present phase-out process of the German hard coal industry with still three active mines there was in 2014 no decommissioning. But the next is at the end of 2015, and the plans for the time after mining have been continued. [German] International war der Markt fuer Steinkohle 2014 erstmals seit langem wieder von einer Stagnation gekennzeichnet. In Deutschland ging der Steinkohlenverbrauch sogar deutlich zurueck, vor allem wegen des Rueckgangs in der Stromerzeugung. Hier hat sich die nationale Energiewende nun spuerbar und fuer die Steinkohlennutzung negativ ausgewirkt. Die politischen Weichenstellungen lassen fuer die Zukunft eine weitere erhebliche Abwaertsbewegung erwarten. Bei dem im Auslaufprozess befindlichen deutschen Steinkohlenbergbau mit noch drei aktiven Bergwerken gab es 2014 keine Stilllegung. Doch die naechste steht zum Jahresende 2015 an, und die Planungen fuer die Zeit nach dem Bergbau sind fortgefuehrt worden.

  17. Tissue dose in thorotrast patients

    International Nuclear Information System (INIS)

    Kaul, A.; Noffz, W.

    1978-01-01

    Absorbed doses to the liver, spleen, red marrow, lungs, kidneys, and to various parts of bone tissue were calculated for long-term burdens of intravascularly injected Thorotrast. The estimates were performed for typical injection levels of 10, 30, 50 and 100 ml, based upon best estimates of 232 Th tissue distribution, and steady state activity ratios between the subsequent daughters. Correcting for the α-particle self absorption within Thorotrast aggregates, the mean α-dose to a standard 70-kg man at 30 yr after the injection 0f 25 ml of Thorotrast is 750 rad to the liver, 2100 rad to the spleen, 270 rad to the red marrow, 60-620 rad in various parts of the lung, and 13 rad to the kidneys. Dose rates to various parts of bone tissue (bone surface, compact, and cancellous bone) were estimated by applying the ICRP model on alkaline earth metabolism to the continuous translocation of thorium daughters to bone and to the formation of thorium daughters by decay within bone tissue. The average dose to calcified bone from translocated 224 Ra with its daughters is 18 rad at 30 yr after the injection of 25 ml of Thorotrast. Considering the Spiess-Mays risk coefficient of 0.9-1.7% bone sarcoma/ 100 rad of average skeletal dose from 224 Ra and its daughters, the induction of 1.6-3.1 bone sarcomas per 1000 Thorotrast patients is predicted. (author)

  18. Melting of polydisperse hard disks

    NARCIS (Netherlands)

    Pronk, S.; Frenkel, D.

    2004-01-01

    The melting of a polydisperse hard-disk system is investigated by Monte Carlo simulations in the semigrand canonical ensemble. This is done in the context of possible continuous melting by a dislocation-unbinding mechanism, as an extension of the two-dimensional hard-disk melting problem. We find

  19. Studying Hardness Meter Spring Strength to Understand Hardness Distribution on Body Surfaces.

    Science.gov (United States)

    Arima, Yoshitaka

    2017-10-01

    For developing a hardness multipoint measurement system for understanding hardness distribution on biological body surfaces, we investigated the spring strength of the contact portion main axis of a biological tissue hardness meter (product name: PEK). We measured the hardness of three-layered sheets of six types of gel sheets (90 mm × 60 mm × 6 mm) constituting the acupuncture practice pads, with PEK measurements of 1.96 N, 2.94 N, 3.92 N, 4.90 N, 5.88 N, 6.86 N, 7.84 N, 8.82 N, and 9.81 N of the main axis spring strength. We obtained measurements 10 times for the gel sheets and simultaneously measured the load using a digital scale. We measured the hardness distribution of induration embedded and breast cancer palpation models, with a main axis with 1.96 N, 4.90 N, and 9.81 N spring strengths, to create a two-dimensional Contour Fill Chart. Using 4.90 N spring strength, we could obtain measurement loads of ≤3.0 N, and the mean hardness was 5.14 mm. This was close to the median of the total measurement range 0.0-10.0 mm, making the measurement range the largest for this spring strength. We could image the induration of the induration-embedded model regardless of the spring strength. Overall, 4.90 N spring strength was best suited for imaging cancer in the breast cancer palpation model. Copyright © 2017. Published by Elsevier B.V.

  20. Effect of calcified plaques on estimation of arterial stenosis of lower extremity in diabetic foot patients using multislice computed tomography angiography

    International Nuclear Information System (INIS)

    Yu Xiaojing; Jin Yan; Wang Ge; Li Chunzhi; Zhang Yi; Ren Hua

    2013-01-01

    Objective: To investigate the impacts of calcified plaques on estimation of arterial stenosis of lower extremity in diabetic foot patients using 16 -slice computed tomography angiography (MSCTA). Materials and Methods: Thirty-five patients (representing 38 cases)underwent both MSCTA and digital subtraction angiography (DSA) examinations. The arteries of lower extremity were divided into 15 anatomic segments, and the degree of artery stenosis in each segment was classified as normal, mildly, moderately. severely or occluded. The extent of calcification in each segment was also assessed on cross -sectional image of MDCTA and was classified as absent, mildly, moderately, or severely. Using DSA as the standard reference, the sensitivity, specificity, accuracy, Youden index, positive predictive value and negative predictive value of MSCTA were calculated. Agreement between MSCTA and DSA was assessed by Cohen's kappa statistics. Results: In the noncalcified, mildly and moderately calcified segments of the artery above the knee, for the detection of segments that had more than mild stenosis, the sensitivity, specificity, accuracy. Youden index, positive predictive value and negative predictive value of MSCTA were 97.1%, 98.7%, 98.2%, 95.8%, 97.0% and 98.7%, respectively. In the severely calcified segments of the artery above the knee, for the detection of segments that had more than mild stenosis, the sensitivity, specificity, accuracy, Youden index, positive predictive value and negative predictive value of MSCTA were 96.3%, 93.8%, 94.7%, 90.1%, 89.7% and 97.8%, respectively. In the noncalcified, mildly and moderately calcified segments of the artery below the knee, for the detection of segments that had more than mild stenosis, the sensitivity, specificity, accuracy, Youden index, positive predictive value and negative predictive value of MSCTA were 95.1%, 93.2%, 94.1%, 88.3%, 93.4% and 94.9%, respectively. In the severely calcified segments of the artery below the

  1. Calcified Cavitating Mesenteric Lymph Node Syndrome: Case Presentation and Literature Review

    Directory of Open Access Journals (Sweden)

    Dipinder S Keer

    2010-01-01

    Full Text Available Cavitating mesenteric lymph node syndrome (CMLNS is a rare complication of celiac disease. Globally, only 36 cases of CMLNS have been reported to date. The present article reports an incidence of its unique pathology and possible complications of celiac disease, followed by a review of the syndrome. A case involving a 51-year-old man with celiac disease who was referred to hospital because of a non-tender abdominal mass is described. Plain film x-ray of the abdomen revealed fine curvilinear calcifications in the left lower quadrant. A complex, cystic-appearing, lobulated mass with somewhat echogenic walls most consistent with calcifications was revealed on subsequent ultrasound (US imaging. Colour Doppler imaging showed no evidence of vascularity within the lesion. Computed tomography (CT imaging showed a thin rim of calcification in the walls of multiple cystic components. Enhanced magnetic resonance (MR imaging revealed a mixed solid and cystic multiloculated mass, with fat-fluid layers originating from the root of the small bowel mesentery. A CT-guided biopsy was performed. The fine-needle aspirate revealed calcified matter with no associated cellular material. No malignant cells were seen; CMLNS was established as the diagnosis. To the authors’ knowledge, there are no previous reports in the literature describing the finding of rim calcification on US or MR imaging in the setting of CMLNS. CMLNS is an important diagnosis to consider, particularly in patients with a history of celiac disease. The finding of rim calcification on US in the setting of cavitating mesenteric adenopathy should prompt further diagnostic imaging studies such as CT or MR imaging. These may lead to additional pathology studies such as a CT-guided biopsy to further characterize the lesion at the cellular level, to investigate potential malignancy and to further guide follow-up and patient management.

  2. Reef calcifiers are adapted to episodic heat stress but vulnerable to sustained warming.

    Science.gov (United States)

    Stuhr, Marleen; Reymond, Claire E; Rieder, Vera; Hallock, Pamela; Rahnenführer, Jörg; Westphal, Hildegard; Kucera, Michal

    2017-01-01

    Shallow marine ecosystems naturally experience fluctuating physicochemical conditions across spatial and temporal scales. Widespread coral-bleaching events, induced by prolonged heat stress, highlight the importance of how the duration and frequency of thermal stress influence the adaptive physiology of photosymbiotic calcifiers. Large benthic foraminifera harboring algal endosymbionts are major tropical carbonate producers and bioindicators of ecosystem health. Like corals, they are sensitive to thermal stress and bleach at temperatures temporarily occurring in their natural habitat and projected to happen more frequently. However, their thermal tolerance has been studied so far only by chronic exposure, so how they respond under more realistic episodic heat-event scenarios remains unknown. Here, we determined the physiological responses of Amphistegina gibbosa, an abundant western Atlantic foraminifera, to four different treatments--control, single, episodic, and chronic exposure to the same thermal stress (32°C)--in controlled laboratory cultures. Exposure to chronic thermal stress reduced motility and growth, while antioxidant capacity was elevated, and photosymbiont variables (coloration, oxygen-production rates, chlorophyll a concentration) indicated extensive bleaching. In contrast, single- and episodic-stress treatments were associated with higher motility and growth, while photosymbiont variables remained stable. The effects of single and episodic heat events were similar, except for the presumable occurrence of reproduction, which seemed to be suppressed by both episodic and chronic stress. The otherwise different responses between treatments with thermal fluctuations and chronic stress indicate adaptation to thermal peaks, but not to chronic exposure expected to ensue when baseline temperatures are elevated by climate change. This firstly implies that marine habitats with a history of fluctuating thermal stress potentially support resilient

  3. Viability of calcifying bacterial formulations in fly ash for applications in building materials.

    Science.gov (United States)

    Dhami, Navdeep Kaur; Mukherjee, Abhijit; Reddy, M Sudhakara

    2013-12-01

    Evidence of bacterial involvement in precipitation of calcium carbonates has brought a revolution in the field of applied microbiology, geotechnical sciences, environmental and civil engineering with its marked success in restoration of various building materials. For applications of these calcite binder-producing bacterial cultures, different expensive carrier materials have been used but their high costs have come in the way of their successful commercialization. In the present study, we have explored the potential of cheap industrial by-product fly ash as a carrier material for bacterial cells and investigated the viability of calcifying bacterial isolates: Bacillus megaterium, Bacillus cereus, and Lysinibacillus fusiformis in fly ash carrier at varying temperatures and moisture conditions along with biomineralization efficacy of these formulations. We used laser scanning confocal microscopy to analyze the viability of bacteria by florescent dye 5-cyano-2,3-ditolyl tetrazolium chloride (CTC) along with the plate count method. Results revealed that fly ash successfully served as an effective carrier material and bacterial formulations stored at 4 °C provided longer shelf life than those stored at higher temperatures. Up to 10(6) cfu/g was found to sustain in all formulations at 4 °C compared to 10(4)-10(5) cfu/g in case of higher temperatures up to 1 year. For 4 °C, higher moistures (50 %) were found to provide better survivability while for higher temperatures, lower moistures (30 %) favored higher viability. The biomineralization capability of fresh and formulated bacterial cells was compared on the basis of precipitation of carbonates and it was found that carbonate precipitation efficacy of formulated bacterial cells was comparable to fresh bacterial cells.

  4. Osteoclasts but not osteoblasts are affected by a calcified surface treated with zoledronic acid in vitro

    International Nuclear Information System (INIS)

    Schindeler, Aaron; Little, David G.

    2005-01-01

    Bisphosphonates are potent inhibitors of osteoclast-mediated bone resorption. Recent interest has centered on the effects of bisphosphonates on osteoblasts. Chronic dosing of osteoblasts with solubilized bisphosphonates has been reported to enhance osteogenesis and mineralization in vitro. However, this methodology poorly reflects the in vivo situation, where free bisphosphonate becomes rapidly bound to mineralized bone surfaces. To establish a more clinically relevant cell culture model, we cultured bone cells on calcium phosphate coated quartz discs pre-treated with the potent nitrogen-containing bisphosphonate, zoledronic acid (ZA). Binding studies utilizing [ 14 C]-labeled ZA confirmed that the bisphosphonate bound in a concentration-dependent manner over the 1-50 μM dose range. When grown on ZA-treated discs, the viability of bone-marrow derived osteoclasts was greatly reduced, while the viability and mineralization of the osteoblastic MC3T3-E1 cell line were largely unaffected. This suggests that only bone resorbing cells are affected by bound bisphosphonate. However, this system does not account for transient exposure to unbound bisphosphonate in the hours following a clinical dosing. To model this event, we transiently treated osteoblasts with ZA in the absence of a calcified surface. Osteoblasts proved highly resistant to all transitory treatment regimes, even when utilizing ZA concentrations that prevented mineralization and/or induced cell death when dosed chronically. This study represents a pharmacologically more relevant approach to modeling bisphosphonate treatment on cultured bone cells and implies that bisphosphonate therapies may not directly affect osteoblasts at bone surfaces

  5. Engineering Musculoskeletal Tissue Interfaces

    Directory of Open Access Journals (Sweden)

    Ece Bayrak

    2018-04-01

    Full Text Available Tissue engineering aims to bring together biomaterials, cells, and signaling molecules within properly designed microenvironments in order to create viable treatment options for the lost or malfunctioning tissues. Design and production of scaffolds and cell-laden grafts that mimic the complex structural and functional features of tissues are among the most important elements of tissue engineering strategy. Although all tissues have their own complex structure, an even more complex case in terms of engineering a proper carrier material is encountered at the tissue interfaces, where two distinct tissues come together. The interfaces in the body can be examined in four categories; cartilage-bone and ligament-bone interfaces at the knee and the spine, tendon-bone interfaces at the shoulder and the feet, and muscle-tendon interface at the skeletal system. These interfaces are seen mainly at the soft-to-hard tissue transitions and they are especially susceptible to injury and tear due to the biomechanical inconsistency between these tissues where high strain fields are present. Therefore, engineering the musculoskeletal tissue interfaces remain a challenge. This review focuses on recent advancements in strategies for musculoskeletal interface engineering using different biomaterial-based platforms and surface modification techniques.

  6. Hardness variability in commercial technologies

    International Nuclear Information System (INIS)

    Shaneyfelt, M.R.; Winokur, P.S.; Meisenheimer, T.L.; Sexton, F.W.; Roeske, S.B.; Knoll, M.G.

    1994-01-01

    The radiation hardness of commercial Floating Gate 256K E 2 PROMs from a single diffusion lot was observed to vary between 5 to 25 krad(Si) when irradiated at a low dose rate of 64 mrad(Si)/s. Additional variations in E 2 PROM hardness were found to depend on bias condition and failure mode (i.e., inability to read or write the memory), as well as the foundry at which the part was manufactured. This variability is related to system requirements, and it is shown that hardness level and variability affect the allowable mode of operation for E 2 PROMs in space applications. The radiation hardness of commercial 1-Mbit CMOS SRAMs from Micron, Hitachi, and Sony irradiated at 147 rad(Si)/s was approximately 12, 13, and 19 krad(Si), respectively. These failure levels appear to be related to increases in leakage current during irradiation. Hardness of SRAMs from each manufacturer varied by less than 20%, but differences between manufacturers are significant. The Qualified Manufacturer's List approach to radiation hardness assurance is suggested as a way to reduce variability and to improve the hardness level of commercial technologies

  7. On scale dependence of hardness

    International Nuclear Information System (INIS)

    Shorshorov, M.Kh.; Alekhin, V.P.; Bulychev, S.I.

    1977-01-01

    The concept of hardness as a structure-sensitive characteristic of a material is considered. It is shown that in conditions of a decreasing stress field under the inventor the hardness function is determined by the average distance, Lsub(a), between the stops (fixed and sessile dislocations, segregation particles, etc.). In the general case, Lsub(a) depends on the size of the impression and explains the great diversity of hardness functions. The concept of average true deformation rate on depression is introduced

  8. Dual-energy computed tomography for characterizing urinary calcified calculi and uric acid calculi: A meta-analysis

    International Nuclear Information System (INIS)

    Zheng, Xingju; Liu, Yuanyuan; Li, Mou; Wang, Qiyan; Song, Bin

    2016-01-01

    Objective: A meta-analysis was conducted to determine the accuracy of dual-energy computed tomography (DECT) for differentiating urinary uric acid and calcified calculi. Methods: The databases PubMed, EMBASE, Web of Science, and the Cochrane Library were searched up to May 2016 for relevant original studies. Data were extracted to calculate the pooled sensitivity, specificity, diagnostic odds ratio (OR), positive and negative likelihood ratios (PLR and NLR), and areas under summary receiver operating characteristic (AUROC) curves for analysis. Results: Nine studies (609 stones in 415 patients) were included. For differentiating uric acid (UA) and non-UA calculi with DECT, the analysis indicated: pooled weighted sensitivity, 0.955 (95% CI, 0.888–0.987); specificity, 0.985 (95% CI, 0.970–0.993); PLR, 0.084 (95% CI, 0.041–0.170); NLR 33.327 (95% CI, 18.516–59.985); and diagnostic OR 538.18 (95% CI, 195.50–1478.5). The AUROC value was 0.9901. For calcified stones, the analysis indicated: pooled weighted sensitivity, 0.994 (95% CI, 0.969–1); specificity, 0.973 (95% CI, 0.906–0.997); PLR, 11.200 (95% CI, 4.922–25.486); NLR 0.027 (95% CI, 0.010–0.072); and diagnostic OR 654.89 (95% CI, 151.31–2834.4). The AUROC value was 0.9915. Conclusion: This meta-analysis found that DECT is a highly accurate noninvasive method for characterizing urinary uric acid and calcified calculi.

  9. Upper Devonian (Frasnian) non-calcified, algae, Alberta: Geological relevance to Leduc platforms and petroleum source rocks

    Energy Technology Data Exchange (ETDEWEB)

    Dix, G.R. (Univ. of British Columbia, Vancouver, BC (Canada))

    1990-12-01

    Several types of non-calcified fossil algae comparable to extant brown and green benithic macrophytes occur abundantly on two bedding planes in drill core from argillaceous slope carbonates of the Ireton Formation in northern Alberta. Fossiliferous strata abruptly overlie part of a stepped-back margin of the Sturgeon Lake carbonate platform (Leduc Formation), southeast of the Peace River Arch. Fossils are flattened organic fragments, some representing nearly complete specimens. Tentative comparisons are made with some Paleozoic algae; some of the Sturgeon Lake flora may be new species or genera. Preliminary examination of selected cores from the Ireton Formation and organic-rich Duvernay Formation in central Alberta indicates a widespread distribution of algal-derived organic matter within Upper Devonian basinal strata. The geological relevance of non-calcified algae to Devonian carbonate platforms and basins is postulated in three cases. Their presence in slope sediments may indicate that algal lawns flourished in muddy, upper slope environments. Fossils accumulated either in situ, or were ripped up and quickly buried within downshope resedimented deposits. All or some algal fragments may have been swept from the adjacent carbonate platform during storms. Prolific shallow water algal growth may have occurred simultaneously with oceanic crises when shallow water carbonate production either decreased or was shut down. The present position of fossil algae, therefore, would mark a bedding surface that is stratigraphically equivalent to an intraplatform disconformity. Regardless of the original environment, a sufficient accumulation of non-calcified algae in slope strata represents a viable petroleum source proximal to carbonate platforms. 46 refs., 9 figs.

  10. Cost-effectiveness analysis of orbital atherectomy plus balloon angioplasty vs balloon angioplasty alone in subjects with calcified femoropopliteal lesions

    Science.gov (United States)

    Weinstock, Barry; Dattilo, Raymond; Diage, Tiffini

    2014-01-01

    Introduction As cost considerations become increasingly critical when selecting optimal endovascular treatment strategies, a cost-benefit analysis was conducted comparing the Diamondback 360°® Orbital Atherectomy System (OAS) (Cardiovascular Systems, Inc., St Paul, MN, USA) and balloon angioplasty (BA) vs BA alone for treatment of calcified femoropopliteal lesions. Patients and methods The clinical outcomes from COMPLIANCE 360°, a prospective, multicenter, randomized study comparing OAS+BA vs BA alone for treatment of calcified femoropopliteal lesions, were correlated with cost data and previously published quality of life data. Site of service, hospital charges, and associated medical resource utilization were obtained from Uniform Billing statements for index treatments and associated revascularizations out to 1 year. Hospital costs were estimated using hospital-specific, procedure-specific cost-to-charge ratios. Length of stay and procedural data were collected from participating study sites. Results Twenty-five subjects with 38 lesions and 25 subjects with 27 lesions were randomized to the OAS+BA and BA-alone groups, respectively. Mean hospital charges (US$51,755 vs US$39,922) and estimated hospital costs (US$15,100 vs US$11,016) were higher for OAS+BA compared with BA alone (not statistically significant). Stent utilization was statistically significantly higher with BA-alone treatment for all subjects (1.1 vs 0.1, P=0.001) and in the subset of subjects with one lesion (1.0 vs 0.1, Patherectomy for treatment of calcified femoropopliteal lesions, a longstanding challenge for peripheral artery disease interventionalists. PMID:24672251

  11. Calcifying invertebrates succeed in a naturally CO2-rich coastal habitat but are threatened by high levels of future acidification

    Directory of Open Access Journals (Sweden)

    M. Wahl

    2010-11-01

    Full Text Available CO2 emissions are leading to an acidification of the oceans. Predicting marine community vulnerability towards acidification is difficult, as adaptation processes cannot be accounted for in most experimental studies. Naturally CO2 enriched sites thus can serve as valuable proxies for future changes in community structure. Here we describe a natural analogue site in the Western Baltic Sea. Seawater pCO2 in Kiel Fjord is elevated for large parts of the year due to upwelling of CO2 rich waters. Peak pCO2 values of >230 Pa (>2300 μatm and pHNBS values of pCO2 values are ~70 Pa (~700 μatm. In contrast to previously described naturally CO2 enriched sites that have suggested a progressive displacement of calcifying auto- and heterotrophic species, the macrobenthic community in Kiel Fjord is dominated by calcifying invertebrates. We show that blue mussels from Kiel Fjord can maintain control rates of somatic and shell growth at a pCO2 of 142 Pa (1400 μatm, pHNBS = 7.7. Juvenile mussel recruitment peaks during the summer months, when high water pCO2 values of ~100 Pa (~1000 μatm prevail. Our findings indicate that calcifying keystone species may be able to cope with surface ocean pHNBS values projected for the end of this century when food supply is sufficient. However, owing to non-linear synergistic effects of future acidification and upwelling of corrosive water, peak seawater pCO2 in Kiel Fjord and many other productive estuarine habitats could increase to values >400 Pa (>4000 μatm. These changes will most likely affect calcification and recruitment, and increase external shell dissolution.

  12. Dual-energy computed tomography for characterizing urinary calcified calculi and uric acid calculi: A meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Xingju; Liu, Yuanyuan; Li, Mou; Wang, Qiyan; Song, Bin, E-mail: binsong65@yahoo.com

    2016-10-15

    Objective: A meta-analysis was conducted to determine the accuracy of dual-energy computed tomography (DECT) for differentiating urinary uric acid and calcified calculi. Methods: The databases PubMed, EMBASE, Web of Science, and the Cochrane Library were searched up to May 2016 for relevant original studies. Data were extracted to calculate the pooled sensitivity, specificity, diagnostic odds ratio (OR), positive and negative likelihood ratios (PLR and NLR), and areas under summary receiver operating characteristic (AUROC) curves for analysis. Results: Nine studies (609 stones in 415 patients) were included. For differentiating uric acid (UA) and non-UA calculi with DECT, the analysis indicated: pooled weighted sensitivity, 0.955 (95% CI, 0.888–0.987); specificity, 0.985 (95% CI, 0.970–0.993); PLR, 0.084 (95% CI, 0.041–0.170); NLR 33.327 (95% CI, 18.516–59.985); and diagnostic OR 538.18 (95% CI, 195.50–1478.5). The AUROC value was 0.9901. For calcified stones, the analysis indicated: pooled weighted sensitivity, 0.994 (95% CI, 0.969–1); specificity, 0.973 (95% CI, 0.906–0.997); PLR, 11.200 (95% CI, 4.922–25.486); NLR 0.027 (95% CI, 0.010–0.072); and diagnostic OR 654.89 (95% CI, 151.31–2834.4). The AUROC value was 0.9915. Conclusion: This meta-analysis found that DECT is a highly accurate noninvasive method for characterizing urinary uric acid and calcified calculi.

  13. Photon technology. Hard photon technology; Photon technology. Hard photon gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    Research results of hard photon technology have been summarized as a part of novel technology development highly utilizing the quantum nature of photon. Hard photon technology refers to photon beam technologies which use photon in the 0.1 to 200 nm wavelength region. Hard photon has not been used in industry due to the lack of suitable photon sources and optical devices. However, hard photon in this wavelength region is expected to bring about innovations in such areas as ultrafine processing and material synthesis due to its atom selective reaction, inner shell excitation reaction, and spatially high resolution. Then, technological themes and possibility have been surveyed. Although there are principle proposes and their verification of individual technologies for the technologies of hard photon generation, regulation and utilization, they are still far from the practical applications. For the photon source technology, the laser diode pumped driver laser technology, laser plasma photon source technology, synchrotron radiation photon source technology, and vacuum ultraviolet photon source technology are presented. For the optical device technology, the multi-layer film technology for beam mirrors and the non-spherical lens processing technology are introduced. Also are described the reduction lithography technology, hard photon excitation process, and methods of analysis and measurement. 430 refs., 165 figs., 23 tabs.

  14. ORBIT II sub-analysis: Impact of impaired renal function following treatment of severely calcified coronary lesions with the Orbital Atherectomy System.

    Science.gov (United States)

    Lee, Michael S; Lee, Arthur C; Shlofmitz, Richard A; Martinsen, Brad J; Hargus, Nick J; Elder, Mahir D; Généreux, Philippe; Chambers, Jeffrey W

    2017-04-01

    To investigate the safety and efficacy of the coronary Orbital Atherectomy System (OAS) to prepare severely calcified lesions for stent deployment in patients grouped by renal function. Percutaneous coronary intervention (PCI) of severely calcified lesions is associated with increased rates of major adverse cardiac events (MACE), including death, myocardial infarction (MI), and target vessel revascularization (TVR) compared with PCI of non-calcified vessels. Patients with chronic kidney disease (CKD) are at increased risk for MACE after PCI. The impact of CKD on coronary orbital atherectomy treatment has not been well characterized. ORBIT II was a prospective, multicenter trial in the U.S., which enrolled 443 patients with severely calcified coronary lesions. The MACE rate was defined as a composite of cardiac death, MI, and target vessel revascularization. Of the 441 patients enrolled with known estimated glomerular filtration rate (eGFR) values at baseline, 333 (75.5%) patients had eGFR renal impairment had a higher MACE rate through one year follow-up due to a higher rate of periprocedural MI. Interestingly, the rates of cardiac death and revascularization through 1-year were similar in patients with eGFR renal impairment and severely calcified coronary lesions. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. Calcified pulmonary thromboembolism in a child with sickle cell disease: value of multidetector CT in patients with acute chest syndrome

    International Nuclear Information System (INIS)

    Staser, Jonathan A.; Alam, Tariq; Applegate, Kimberly

    2006-01-01

    The incidence of pulmonary embolism in children is not clearly known, but is believed to be low. Risk factors for pulmonary thromboembolism include central venous catheter, malignancy, surgery, infection, trauma, and congenital hypercoagulable disorders. Children with sickle cell disease are prothrombotic and are at an increased risk of thromboembolism. The incidence of this event is unknown because these children are often not thoroughly imaged. We report here a case of a calcified pulmonary thromboembolism in a child with sickle cell disease and emphasize the use of multidetector CT in detection of pulmonary thromboembolism in children with sickle cell disease. (orig.)

  16. Sequencing ancient calcified dental plaque shows changes in oral microbiota with dietary shifts of the Neolithic and Industrial revolutions

    OpenAIRE

    Adler, Christina J; Dobney, Keith; Weyrich, Laura S; Kaidonis, John; Walker, Alan W; Haak, Wolfgang; Bradshaw, Corey JA; Townsend, Grant; Sołtysiak, Arkadiusz; Alt, Kurt W; Parkhill, Julian; Cooper, Alan

    2013-01-01

    The importance of commensal microbes for human health is increasingly recognized1-5, yet the impacts of evolutionary changes in human diet and culture on commensal microbiota remain almost unknown. Two of the greatest dietary shifts in human evolution involved the adoption of carbohydrate-rich Neolithic (farming) diets6,7 (beginning ~10,000 years BP6,8), and the more recent advent of industrially processed flour and sugar (~1850)9. Here, we show that calcified dental plaque (dental calculus) ...

  17. Determining the influence of calcification on the failure properties of abdominal aortic aneurysm (AAA) tissue.

    Science.gov (United States)

    O'Leary, Siobhan A; Mulvihill, John J; Barrett, Hilary E; Kavanagh, Eamon G; Walsh, Michael T; McGloughlin, Tim M; Doyle, Barry J

    2015-02-01

    Varying degrees of calcification are present in most abdominal aortic aneurysms (AAAs). However, their impact on AAA failure properties and AAA rupture risk is unclear. The aim of this work is evaluate and compare the failure properties of partially calcified and predominantly fibrous AAA tissue and investigate the potential reasons for failure. Uniaxial mechanical testing was performed on AAA samples harvested from 31 patients undergoing open surgical repair. Individual tensile samples were divided into two groups: fibrous (n=31) and partially calcified (n=38). The presence of calcification was confirmed by fourier transform infrared spectroscopy (FTIR). A total of 69 mechanical tests were performed and the failure stretch (λf), failure stress (σf) and failure tension (Tf) were recorded for each test. Following mechanical testing, the failure sites of a subset of both tissue types were examined using scanning electron microscopy (SEM)/energy dispersive X-ray spectroscopy (EDS) to investigate the potential reasons for failure. It has been shown that the failure properties of partially calcified tissue are significantly reduced compared to fibrous tissue and SEM and EDS results suggest that the junction between a calcification deposit and the fibrous matrix is highly susceptible to failure. This study implicates the presence of calcification as a key player in AAA rupture risk and provides further motivation for the development of non-invasive methods of measuring calcification. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. The caries environment: saliva, pellicle, diet, and hard tissue ultrastructure.

    Science.gov (United States)

    Hara, Anderson T; Zero, Domenick T

    2010-07-01

    The pathogenicity of the dental biofilm is modified by salivary and dietary factors, as well as by the characteristics of the tooth structure. The composition of the acquired pellicle can modify the mineral homeostasis of the tooth surfaces and the attachment of bacteria for the development of the biofilm. The substitution of sucrose from the diet by other less cariogenic sugars and/or sugar substitutes can contribute to reducing the pathogenicity of the biofilm. Saliva clears, dilutes, neutralizes, and buffers acids produced by the biofilm. In addition, saliva provides the biofilm/tooth structure with Ca(2+) PO(4)(3-) and F(-) ions, which can positively affect the equilibrium between demineralization-remineralization toward the remineralization and modify the susceptibility of the tooth structure to caries progression. Copyright 2010 Elsevier Inc. All rights reserved.

  19. Functional Coatings or Films for Hard-Tissue Applications

    Directory of Open Access Journals (Sweden)

    Guocheng Wang

    2010-07-01

    Full Text Available Metallic biomaterials like stainless steel, Co-based alloy, Ti and its alloys are widely used as artificial hip joints, bone plates and dental implants due to their excellent mechanical properties and endurance. However, there are some surface-originated problems associated with the metallic implants: corrosion and wear in biological environments resulting in ions release and formation of wear debris; poor implant fixation resulting from lack of osteoconductivity and osteoinductivity; implant-associated infections due to the bacterial adhesion and colonization at the implantation site. For overcoming these surface-originated problems, a variety of surface modification techniques have been used on metallic implants, including chemical treatments, physical methods and biological methods. This review surveys coatings that serve to provide properties of anti-corrosion and anti-wear, biocompatibility and bioactivity, and antibacterial activity.

  20. Calcifying Tendonitis of the Shoulder: Risk Factors and Effectiveness of Acetic Acid Iontophoresis and Ultrasound

    Directory of Open Access Journals (Sweden)

    Fernández Cuadros

    2016-09-01

    Full Text Available Objectives To clinically characterize calcifying tendonitis of the shoulder (CT through a prospective quasi-experimental before-and-after study, which provides a level of demonstrable evidence to support the decision-making and demonstrate the effectiveness of acetic acid iontophoresis and ultrasound in the treatment of CT. Methods Prospective, quasi-experimental before-after intervention study was conducted on 44 patients who referred to the rehabilitation department, Santísima Trinidad’s General Foundation hospital, Salamanca, from June 2014 to April 2016. Outcome measures: 1 Pain: measured by visual analogical scale (VAS; 2 calcification size: in millimetres, both measured radiologically at the beginning/end of treatment; 3 Intervention: Iontophoresis with 5% acetic acid at 4.7 mA × 10 minutes and continuous ultrasound 1 W/cm2 /1 MHz × 5 minutes over calcification. Results Mean age of the subjects was 54.2 years (n = 44, 65.9% female (n = 29, (95% with supraspinatus tendon (n = 38 and 5% with subscapularis (n = 2; 55% had complication in left shoulder (n = 22, 45% in right shoulder (n = 18 and 4.5% bilateral (n = 2. Regarding the occupation, 59.1% had (n = 26 administrative positions and 40.9% manual jobs (n = 18. On personal history: 34.09% were smoker (n = 15, 4.5% had diabetes (n = 2 and calcium intake secondary to osteoporosis was recorded for 2.27% (n = 1 of the subjects. Regarding radiological type: 68.18% formative (n = 30, 38.72% resorptive (n = 14 were observed. Average number of sessions was 19 and 9.01% (n = 4 of the subjects had treatment complications as intolerance/erythema/burn. Average initial pain was 7.7 points (VAS scale, significantly decreased (P = 0.0000 post treatment to 2.2. Initial average size of calcification was 10 mm and significantly decreased (P = 0.0000 post treatment to 3 mm. With respect to the change of calcification: success/cure rate was 56.8% (n = 25, improvement rate was 25% (n = 11; failure rate

  1. Critical evaluation of gamma-irradiated serum used as feeder in the culture and demonstration of putative nanobacteria and calcifying nanoparticles.

    Directory of Open Access Journals (Sweden)

    Jan Martel

    Full Text Available The culture and demonstration of putative nanobacteria (NB and calcifying nanoparticles (CNP from human and animal tissues has relied primarily on the use of a culture supplement consisting of FBS that had been gamma-irradiated at a dose of 30 kGy (gamma-FBS. The use of gamma-FBS is based on the assumption that this sterilized fluid has been rid entirely of any residual NB/CNP, while it continues to promote the slow growth in culture of NB/CNP from human/animal tissues. We show here that gamma-irradiation (5-50 kGy produces extensive dose-dependent serum protein breakdown as demonstrated through UV and visible light spectrophotometry, fluorometry, Fourier-transformed infrared spectroscopy, and gel electrophoresis. Yet, both gamma-FBS and gamma-irradiated human serum (gamma-HS produce NB/CNP in cell culture conditions that are morphologically and chemically indistinguishable from their normal serum counterparts. Contrary to earlier claims, gamma-FBS does not enhance the formation of NB/CNP from several human body fluids (saliva, urine, ascites, and synovial fluid tested. In the presence of additional precipitating ions, both gamma-irradiated serum (FBS and HS and gamma-irradiated proteins (albumin and fetuin-A retain the inherent dual NB inhibitory and seeding capabilities seen also with their untreated counterparts. By gel electrophoresis, the particles formed from both gamma-FBS and gamma-HS are seen to have assimilated into their scaffold the same smeared protein profiles found in the gamma-irradiated sera. However, their protein compositions as identified by proteomics are virtually identical to those seen with particles formed from untreated serum. Moreover, particles derived from human fluids and cultured in the presence of gamma-FBS contain proteins derived from both gamma-FBS and the human fluid under investigation-a confusing and unprecedented scenario indicating that these particles harbor proteins from both the host tissue and the FBS

  2. Simultaneous rota-stenting and transcatheter aortic valve implantation for patients with heavily calcified coronary stenosis and aortic stenosis

    Directory of Open Access Journals (Sweden)

    Yung-Tsai Lee

    2016-09-01

    Full Text Available Given that coronary artery disease (CAD in octogenarians undergoing transcatheter aortic valve implantation (TAVI often presents with more complex lesions and extensive calcification, rotational atherectomy (RA may be needed in some cases before stenting. However, data regarding the feasibility and safety of simultaneous RA during TAVI using the Medtronic CoreValve (MCV; Medtronic, Minneapolis, MN, USA system are lacking. Three out of 107 (2.8% patients (2 females, average age 85.6 years, mean aortic valve area 0.5 cm2, mean left ventricular ejection fraction 39%, mean Logistic EuroScore 70%, with complex, heavily calcified coronary stenosis, and severe valvular aortic stenosis (AS were treated with TAVI and RA due to high surgical risk. After balloon valvuloplasty, all coronary lesions were successfully treated with RA and stenting, immediately followed by transfemoral TAVI with a self-expandable MCV. Our data suggested that in the very elderly patients with severe and heavily calcified CAD and AS who were turned down for cardiac surgery, RA and stenting followed by TAVI may be performed successfully in a combined, single-stage procedure.

  3. Technique optimization of orbital atherectomy in calcified peripheral lesions of the lower extremities: the CONFIRM series, a prospective multicenter registry.

    Science.gov (United States)

    Das, Tony; Mustapha, Jihad; Indes, Jeffrey; Vorhies, Robert; Beasley, Robert; Doshi, Nilesh; Adams, George L

    2014-01-01

    The purpose of CONFIRM registry series was to evaluate the use of orbital atherectomy (OA) in peripheral lesions of the lower extremities, as well as optimize the technique of OA. Methods of treating calcified arteries (historically a strong predictor of treatment failure) have improved significantly over the past decade and now include minimally invasive endovascular treatments, such as OA with unique versatility in modifying calcific lesions above and below-the-knee. Patients (3135) undergoing OA by more than 350 physicians at over 200 US institutions were enrolled on an "all-comers" basis, resulting in registries that provided site-reported patient demographics, ABI, Rutherford classification, co-morbidities, lesion characteristics, plaque morphology, device usage parameters, and procedural outcomes. Treatment with OA reduced pre-procedural stenosis from an average of 88-35%. Final residual stenosis after adjunctive treatments, typically low-pressure percutaneous transluminal angioplasty (PTA), averaged 10%. Plaque removal was most effective for severely calcified lesions and least effective for soft plaque. Shorter spin times and smaller crown sizes significantly lowered procedural complications which included slow flow (4.4%), embolism (2.2%), and spasm (6.3%), emphasizing the importance of treatment regimens that focus on plaque modification over maximizing luminal gain. The OA technique optimization, which resulted in a change of device usage across the CONFIRM registry series, corresponded to a lower incidence of adverse events irrespective of calcium burden or co-morbidities. Copyright © 2013 The Authors. Wiley Periodicals, Inc.

  4. Arthroscopic Removal and Rotator Cuff Repair Without Acromioplasty for the Treatment of Symptomatic Calcifying Tendinitis of the Supraspinatus Tendon.

    Science.gov (United States)

    Ranalletta, Maximiliano; Rossi, Luciano Andrés; Bongiovanni, Santiago Luis; Tanoira, Ignacio; Piuzzi, Nicolas; Maignon, Gastón

    2015-04-01

    Calcified rotator cuff tendinitis is a common cause of chronic shoulder pain that leads to significant pain and functional limitations. Although most patients respond well to conservative treatment, some eventually require surgical treatment. To evaluate the clinical outcome with arthroscopic removal of calcific deposit and rotator cuff repair without acromioplasty for the treatment of calcific tendinitis of the supraspinatus tendon. Case series; Level of evidence, 4. This study retrospectively evaluated 30 consecutive patients with a mean age of 49.2 years. The mean follow-up was 35 months (range, 24-88 months). Pre- and postoperative functional assessment was performed using the Constant score, University of California Los Angeles (UCLA) score, and Quick Disabilities of the Arm, Shoulder, and Hand (DASH). Pain was assessed by visual analog scale (VAS). Radiographs and magnetic resonance imaging (MRI) were performed to evaluate the recurrence of calcifications and the indemnity of the supraspinatus tendon repair. Significant improvement was obtained for pain (mean VAS, 8.7 before surgery to 0.8 after; P rotator cuff repair without acromioplasty can lead to good results in patients with symptomatic calcifying tendonitis of the supraspinatus tendon.

  5. The potential cost-effectiveness of the Diamondback 360® Coronary Orbital Atherectomy System for treating de novo, severely calcified coronary lesions: an economic modeling approach.

    Science.gov (United States)

    Chambers, Jeffrey; Généreux, Philippe; Lee, Arthur; Lewin, Jack; Young, Christopher; Crittendon, Janna; Mann, Marita; Garrison, Louis P

    2016-04-01

    Patients who undergo percutaneous coronary intervention (PCI) for severely calcified coronary lesions have long been known to have worse clinical and economic outcomes than patients with no or mildly calcified lesions. We sought to assess the likely cost-effectiveness of using the Diamondback 360(®) Orbital Atherectomy System (OAS) in the treatment of de novo, severely calcified lesions from a health-system perspective. In the absence of a head-to-head trial and long-term follow up, cost-effectiveness was based on a modeled synthesis of clinical and economic data. A cost-effectiveness model was used to project the likely economic impact. To estimate the net cost impact, the cost of using the OAS technology in elderly (⩾ 65 years) Medicare patients with de novo severely calcified lesions was compared with cost offsets. Elderly OAS patients from the ORBIT II trial (Evaluate the Safety and Efficacy of OAS in Treating Severely Calcified Coronary Lesions) [ClinicalTrials.gov identifier: NCT01092426] were indirectly compared with similar patients using observational data. For the index procedure, the comparison was with Medicare data, and for both revascularization and cardiac death in the following year, the comparison was with a pooled analysis of the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI)/Acute Catheterization and Urgent Intervention Triage Strategy (ACUITY) trials. After adjusting for differences in age, gender, and comorbidities, the ORBIT II mean index procedure costs were 17% (p economic modeling, the recently approved coronary OAS device is projected to be highly cost-effective for patients who undergo PCI for severely calcified lesions. © The Author(s), 2015.

  6. Over-calcified forms of the coccolithophore Emiliania huxleyi in high-CO2 waters are not preadapted to ocean acidification

    Science.gov (United States)

    von Dassow, Peter; Díaz-Rosas, Francisco; Mahdi Bendif, El; Gaitán-Espitia, Juan-Diego; Mella-Flores, Daniella; Rokitta, Sebastian; John, Uwe; Torres, Rodrigo

    2018-03-01

    Marine multicellular organisms inhabiting waters with natural high fluctuations in pH appear more tolerant to acidification than conspecifics occurring in nearby stable waters, suggesting that environments of fluctuating pH hold genetic reservoirs for adaptation of key groups to ocean acidification (OA). The abundant and cosmopolitan calcifying phytoplankton Emiliania huxleyi exhibits a range of morphotypes with varying degrees of coccolith mineralization. We show that E. huxleyi populations in the naturally acidified upwelling waters of the eastern South Pacific, where pH drops below 7.8 as is predicted for the global surface ocean by the year 2100, are dominated by exceptionally over-calcified morphotypes whose distal coccolith shield can be almost solid calcite. Shifts in morphotype composition of E. huxleyi populations correlate with changes in carbonate system parameters. We tested if these correlations indicate that the hyper-calcified morphotype is adapted to OA. In experimental exposures to present-day vs. future pCO2 (400 vs. 1200 µatm), the over-calcified morphotypes showed the same growth inhibition (-29.1±6.3 %) as moderately calcified morphotypes isolated from non-acidified water (-30.7±8.8 %). Under the high-CO2-low-pH condition, production rates of particulate organic carbon (POC) increased, while production rates of particulate inorganic carbon (PIC) were maintained or decreased slightly (but not significantly), leading to lowered PIC / POC ratios in all strains. There were no consistent correlations of response intensity with strain origin. The high-CO2-low-pH condition affected coccolith morphology equally or more strongly in over-calcified strains compared to moderately calcified strains. High-CO2-low-pH conditions appear not to directly select for exceptionally over-calcified morphotypes over other morphotypes, but perhaps indirectly by ecologically correlated factors. More generally, these results suggest that oceanic planktonic

  7. Production and Characterization of a Novel, Electrospun, Tri-Layer Polycaprolactone Membrane for the Segregated Co-Culture of Bone and Soft Tissue

    Directory of Open Access Journals (Sweden)

    Sasima Puwanun

    2016-06-01

    Full Text Available Composite tissue-engineered constructs combining bone and soft tissue have applications in regenerative medicine, particularly dentistry. This study generated a tri-layer, electrospun, poly-ε-caprolactone membrane, with two microfiber layers separated by a layer of nanofibers, for the spatially segregated culture of mesenchymal progenitor cells (MPCs and fibroblasts. The two cell types were seeded on either side, and cell proliferation and spatial organization were investigated over several weeks. Calcium deposition by MPCs was detected using xylenol orange (XO and the separation between fibroblasts and the calcified matrix was visualized by confocal laser scanning microscopy. SEM confirmed that the scaffold consisted of two layers of micron-diameter fibers with a thin layer of nano-diameter fibers in-between. Complete separation of cell types was maintained and calcified matrix was observed on only one side of the membrane. This novel tri-layer membrane is capable of supporting the formation of a bilayer of calcified and non-calcified connective tissue.

  8. Hard diffraction and rapidity gaps

    International Nuclear Information System (INIS)

    Brandt, A.

    1995-09-01

    The field of hard diffraction, which studies events with a rapidity gap and a hard scattering, has expanded dramatically recently. A review of new results from CDF, D OE, H1 and ZEUS will be given. These results include diffractive jet production, deep-inelastic scattering in large rapidity gap events, rapidity gaps between high transverse energy jets, and a search for diffractive W-boson production. The combination of these results gives new insight into the exchanged object, believed to be the pomeron. The results axe consistent with factorization and with a hard pomeron that contains both quarks and gluons. There is also evidence for the exchange of a strongly interacting color singlet in high momentum transfer (36 2 ) events

  9. Initiative hard coal; Initiative Steinkohle

    Energy Technology Data Exchange (ETDEWEB)

    Leonhardt, J.

    2007-08-02

    In order to decrease the import dependence of hard coal in the European Union, the author has submitted suggestions to the director of conventional sources of energy (directorate general for energy and transport) of the European community, which found a positive resonance. These suggestions are summarized in an elaboration 'Initiative Hard Coal'. After clarifying the starting situation and defining the target the presupposition for a better use of hard coal deposits as raw material in the European Union are pointed out. On that basis concrete suggestions for measures are made. Apart from the conditions of the deposits it concerns thereby also new mining techniques and mining-economical developments, connected with tasks for the mining-machine industry. (orig.)

  10. State of the art in hard-on-hard bearings: how did we get here and what have we achieved?

    Science.gov (United States)

    Zywiel, Michael G; Sayeed, Siraj A; Johnson, Aaron J; Schmalzried, Thomas P; Mont, Michael A

    2011-03-01

    Total hip arthroplasty has shown excellent results in decreasing pain and improving function in patients with degenerative disease of the hip. Improvements in prosthetic materials, designs and implant fixation have now resulted in wear of the bearing surface being the limitation of this technology, and a number of hard-on-hard couples have been introduced to address this concern. The purpose of this article is to review the origins, development, survival rates and potential advantages and disadvantages of the following hard-on-hard bearings for total hip arthroplasty: metal-on-metal standard total hip arthroplasty; metal-on-metal hip resurfacing arthroplasty, ceramic-on-ceramic total hip arthroplasty; and ceramic-on-metal bearings. Improvements in the manufacturing of metal-on-metal bearings over the past 50 years have resulted in implants that provide low wear rates and allow for the use of large femoral heads. However, concerns remain regarding elevated serum metal ion levels, potential teratogenic effects and potentially devastating adverse local tissue reactions, whose incidence and pathogenesis remains unclear. Modern total hip resurfacing has shown excellent outcomes over 10 years in the hands of experienced surgeons. Current ceramic-on-ceramic bearings have demonstrated excellent survival with exceptionally low wear rates and virtually no local adverse effects. Concerns remain for insertional chipping, in vivo fracture and the variable incidence of squeaking. Contemporary ceramic-on-metal interfaces are in the early stages of clinical use, with little data reported to date. Hard-on-hard bearings for total hip arthroplasty have improved dramatically over the past 50 years. As bearing designs continue to improve with new and modified materials and improved manufacturing techniques, it is likely that the use of hard-on-hard bearings will continue to increase, especially in young and active patients.

  11. Photon technology. Hard photon technology; Photon technology. Hard photon gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    For the application of photon to industrial technologies, in particular, a hard photon technology was surveyed which uses photon beams of 0.1-200nm in wavelength. Its features such as selective atom reaction, dense inner shell excitation and spacial high resolution by quantum energy are expected to provide innovative techniques for various field such as fine machining, material synthesis and advanced inspection technology. This wavelength region has been hardly utilized for industrial fields because of poor development of suitable photon sources and optical devices. The developmental meaning, usable time and issue of a hard photon reduction lithography were surveyed as lithography in ultra-fine region below 0.1{mu}m. On hard photon analysis/evaluation technology, the industrial use of analysis, measurement and evaluation technologies by micro-beam was viewed, and optimum photon sources and optical systems were surveyed. Prediction of surface and surface layer modification by inner shell excitation, the future trend of this process and development of a vacuum ultraviolet light source were also surveyed. 383 refs., 153 figs., 17 tabs.

  12. Evaluation of hard fossil fuel

    International Nuclear Information System (INIS)

    Zivkovic, S.; Nuic, J.

    1999-01-01

    Because of its inexhaustible supplies hard fossil fuel will represent the pillar of the power systems of the 21st century. Only high-calorie fossil fuels have the market value and participate in the world trade. Low-calorie fossil fuels ((brown coal and lignite) are fuels spent on the spot and their value is indirectly expressed through manufactured kWh. For the purpose of determining the real value of a tonne of low-calorie coal, the criteria that help in establishing the value of a tonne of hard coal have to be corrected and thus evaluated and assessed at the market. (author)

  13. Calorimeter triggers for hard collisions

    International Nuclear Information System (INIS)

    Landshoff, P.V.; Polkinghorne, J.C.

    1978-01-01

    We discuss the use of a forward calorimeter to trigger on hard hadron-hadron collisions. We give a derivation in the covariant parton model of the Ochs-Stodolsky scaling law for single-hard-scattering processes, and investigate the conditions when instead a multiple- scattering mechanism might dominate. With a proton beam, this mechanism results in six transverse jets, with a total average multiplicity about twice that seen in ordinary events. We estimate that its cross section is likely to be experimentally accessible at avalues of the beam energy in the region of 100 GeV/c

  14. Hardness of ion implanted ceramics

    International Nuclear Information System (INIS)

    Oliver, W.C.; McHargue, C.J.; Farlow, G.C.; White, C.W.

    1985-01-01

    It has been established that the wear behavior of ceramic materials can be modified through ion implantation. Studies have been done to characterize the effect of implantation on the structure and composition of ceramic surfaces. To understand how these changes affect the wear properties of the ceramic, other mechanical properties must be measured. To accomplish this, a commercially available ultra low load hardness tester has been used to characterize Al 2 O 3 with different implanted species and doses. The hardness of the base material is compared with the highly damaged crystalline state as well as the amorphous material

  15. Chemical hardness and density functional theory

    Indian Academy of Sciences (India)

    Unknown

    RALPH G PEARSON. Chemistry Department, University of California, Santa Barbara, CA 93106, USA. Abstract. The concept of chemical hardness is reviewed from a personal point of view. Keywords. Hardness; softness; hard & soft acids bases (HSAB); principle of maximum hardness. (PMH) density functional theory (DFT) ...

  16. Proton microprobe analysis of zinc in skeletal tissues

    International Nuclear Information System (INIS)

    Doty, S.B.; Jones, K.W.; Kraner, H.W.; Shroy, R.E.; Hanson, A.L.

    1981-01-01

    A proton microprobe with windowless exit port has been used to study zinc distributions in various types of skeletal tissues. The use of an external beam facilitated positioning of the targets for examination of particular points of interest. The proton micorprobe is uniquely suited to this work since it combines high sensitivity for zinc determinations in thick samples with good spatial resolution. Our measurements on rat and rabbit Achilles tendon showed a significant increase in zinc concentrations as the beam moved from the unmineralized collagen into the mineralized attachment site. Cartilage gave a similar result, with calcified cartilage having a greater zinc level than the articular surface on unmineralized epiphyseal cartilage. (orig.)

  17. Proton microprobe analysis of zinc in skeletal tissues

    Science.gov (United States)

    Doty, S. B.; Jones, K. W.; Kraner, H. W.; Shroy, R. E.; Hanson, A. L.

    1981-03-01

    A proton microprobe with windowless exit port has been used to study zinc distributions in various types of skeletal tissues. The use of an external beam facilitated positioning of the targets for examination of particular points of interest. The proton microprobe is uniquely suited to this work since it combines high sensitivity for zinc determination in thick samples with good spatial resolution. Our measurements on rat and rabbit Achilles tendon showed a significant increase in zinc concentrations as the beam moved from the unmineralized collagen into the mineralized attachment site. Cartilage gave a similar result, with calcified cartilage having a greater zinc level than the articular surface on unmineralized epiphyseal cartilage.

  18. Proton microprobe analysis of zinc in skeletal tissues

    International Nuclear Information System (INIS)

    Doty, S.B.; Jones, K.W.; Kraner, H.W.; Shroy, R.E.; Hanson, A.L.

    1980-06-01

    A proton microprobe with windowless exit port was used to study zinc distributions in various types of skeletal tissues. The use of an external beam facilitated positioning of the targets for examination of particular points of interest. The proton microprobe is uniquely suited to this work since it combines high sensitivity for zinc determinations in thick samples with good spatial resolution. Measurements on rat and rabbit Achilles tendon showed a significant increase in zinc concentrations as the beam moved from the unmineralized collagen into the mineralized attachment site. Cartilage gave a similar result, with calcified cartilage having a greater zinc level than the articular surface on unmineralized epiphyseal cartilage

  19. Cost-effectiveness analysis of orbital atherectomy plus balloon angioplasty vs balloon angioplasty alone in subjects with calcified femoropopliteal lesions.

    Science.gov (United States)

    Weinstock, Barry; Dattilo, Raymond; Diage, Tiffini

    2014-01-01

    As cost considerations become increasingly critical when selecting optimal endovascular treatment strategies, a cost-benefit analysis was conducted comparing the Diamondback 360°® Orbital Atherectomy System (OAS) (Cardiovascular Systems, Inc., St Paul, MN, USA) and balloon angioplasty (BA) vs BA alone for treatment of calcified femoropopliteal lesions. The clinical outcomes from COMPLIANCE 360°, a prospective, multicenter, randomized study comparing OAS+BA vs BA alone for treatment of calcified femoropopliteal lesions, were correlated with cost data and previously published quality of life data. Site of service, hospital charges, and associated medical resource utilization were obtained from Uniform Billing statements for index treatments and associated revascularizations out to 1 year. Hospital costs were estimated using hospital-specific, procedure-specific cost-to-charge ratios. Length of stay and procedural data were collected from participating study sites. Twenty-five subjects with 38 lesions and 25 subjects with 27 lesions were randomized to the OAS+BA and BA-alone groups, respectively. Mean hospital charges (US$51,755 vs US$39,922) and estimated hospital costs (US$15,100 vs US$11,016) were higher for OAS+BA compared with BA alone (not statistically significant). Stent utilization was statistically significantly higher with BA-alone treatment for all subjects (1.1 vs 0.1, P=0.001) and in the subset of subjects with one lesion (1.0 vs 0.1, Pcost for single-lesion versus multiple-lesion treatment. Using costs and quality-adjusted life years (QALYs) for the single-lesion cohort, the 1-year incremental cost of OAS+BA vs BA alone was US$549, and incremental QALY was 0.16. This results in an incremental cost-effectiveness ratio of US$3,441, well below the US$50,000 threshold. One-year index procedure cost and cost-effectiveness were comparable for OAS+BA vs BA alone. This study provides compelling cost-effectiveness data for using atherectomy for treatment of

  20. Cost-effectiveness analysis of orbital atherectomy plus balloon angioplasty vs balloon angioplasty alone in subjects with calcified femoropopliteal lesions

    Directory of Open Access Journals (Sweden)

    Weinstock B

    2014-03-01

    Full Text Available Barry Weinstock,1 Raymond Dattilo,2 Tiffini Diage3 1Orlando Health Heart Institute, Mid-Florida Cardiology Specialists, Orlando, FL, USA; 2Department of Cardiology, St Francis Health Center, Topeka, KS, USA; 3North American Science Association (NAMSA, Sunnyvale, CA, USA Introduction: As cost considerations become increasingly critical when selecting optimal endovascular treatment strategies, a cost-benefit analysis was conducted comparing the Diamondback 360°® Orbital Atherectomy System (OAS (Cardiovascular Systems, Inc., St Paul, MN, USA and balloon angioplasty (BA vs BA alone for treatment of calcified femoropopliteal lesions. Patients and methods: The clinical outcomes from COMPLIANCE 360°, a prospective, multicenter, randomized study comparing OAS+BA vs BA alone for treatment of calcified femoropopliteal lesions, were correlated with cost data and previously published quality of life data. Site of service, hospital charges, and associated medical resource utilization were obtained from Uniform Billing statements for index treatments and associated revascularizations out to 1 year. Hospital costs were estimated using hospital-specific, procedure-specific cost-to-charge ratios. Length of stay and procedural data were collected from participating study sites. Results: Twenty-five subjects with 38 lesions and 25 subjects with 27 lesions were randomized to the OAS+BA and BA-alone groups, respectively. Mean hospital charges (US$51,755 vs US$39,922 and estimated hospital costs (US$15,100 vs US$11,016 were higher for OAS+BA compared with BA alone (not statistically significant. Stent utilization was statistically significantly higher with BA-alone treatment for all subjects (1.1 vs 0.1, P=0.001 and in the subset of subjects with one lesion (1.0 vs 0.1, P<0.00001. There was a significant difference in cost for single-lesion versus multiple-lesion treatment. Using costs and quality-adjusted life years (QALYs for the single-lesion cohort, the 1-year

  1. Accumulation of low density lipoprotein associated cholesterol in calcifying vesicle fractions correlates with intimal thickening in thoracic aortas of juvenile rabbits fed a supplemental cholesterol diet

    Directory of Open Access Journals (Sweden)

    Culley Nathan C

    2006-10-01

    Full Text Available Abstract Background It has been shown that calcifying vesicles play an important role in aortic calcification and that cholesterol content in the isolated vesicle fraction is increased when rabbits are fed supplemental cholesterol diets. Whether lipoprotein-associated cholesterols and other lipids are also increased in the vesicle fraction and whether the increase correlates with atherosclerosis remain unknown. Results Fourteen juvenile male rabbits fed an atherogenic diet containing 0.5% cholesterol and 2% peanut oil for 3 months developed varying degrees of hypercholesterolemia and intimal thickening in the ascending thoracic aorta. The correlation between these two parameters was insignificant, and likely attributable to the use of small numbers of rabbits in this study. Despite this lack of correlation, we demonstrate that the accumulation of cholesterol in calcifying vesicle fractions obtained from the collagenase-digested aorta fragments correlates well with intimal thickening (r2 = 0.98, p Conclusion When limited numbers of rabbits are used, LDL-C accumulation in calcifying vesicle fractions is a better biomarker for atherosclerosis than LDL-C levels in the serum. The close association of LDL-C with calcifying vesicles may play an important role in atherosclerosis and calcification.

  2. Response of the calcifying coccolithophore Emiliania huxleyi to low pH/high pCO2: from physiology to molecular level

    NARCIS (Netherlands)

    Richier, S.; Fiorini, S.; Kerros, M.E.; von Dassow, P.; Gattuso, J.P.

    2011-01-01

    The emergence of ocean acidification as a significant threat to calcifying organisms in marine ecosystems creates a pressing need to understand the physiological and molecular mechanisms by which calcification is affected by environmental parameters. We report here, for the first time, changes in

  3. Cushing syndrome as presenting symptom of calcifying nested stromal-epithelial tumor of the liver in an adolescent boy: a case report

    NARCIS (Netherlands)

    Weeda, V. B.; de Reuver, Ph R.; Bras, H.; Zsíros, J.; Lamers, W. H.; Aronson, D. C.

    2016-01-01

    Ectopic adrenocorticotropic hormone-producing primary liver tumors are rare, especially in children. We report the case of an adolescent boy of mixed Dutch and Moroccan descent with an adrenocorticotropic hormone-producing calcifying nested stromal-epithelial tumor with long-term follow-up. Thus

  4. Net Loss of CaCO3 from a subtropical calcifying community due to seawater acidification: mesocosm-scale experimental evidence

    Directory of Open Access Journals (Sweden)

    K. S. Rodgers

    2009-08-01

    Full Text Available Acidification of seawater owing to oceanic uptake of atmospheric CO2 originating from human activities such as burning of fossil fuels and land-use changes has raised serious concerns regarding its adverse effects on corals and calcifying communities. Here we demonstrate a net loss of calcium carbonate (CaCO3 material as a result of decreased calcification and increased carbonate dissolution from replicated subtropical coral reef communities (n=3 incubated in continuous-flow mesocosms subject to future seawater conditions. The calcifying community was dominated by the coral Montipora capitata. Daily average community calcification or Net Ecosystem Calcification (NEC=CaCO3 productio