  1. A Hands-Free Interface for Controlling Virtual Electric-Powered Wheelchairs

    Directory of Open Access Journals (Sweden)

    Tauseef Gulrez

    2016-03-01

    Full Text Available This paper focuses on how to provide mobility to people with motor impairments with the integration of robotics and wearable computing systems. The burden of learning to control powered mobility devices should not fall entirely on the people with disabilities. Instead, the system should be able to learn the user's movements. This requires learning the degrees of freedom of user movement, and mapping these degrees of freedom onto electric-powered wheelchair (EPW controls. Such mapping cannot be static because in some cases users will eventually improve with practice. Our goal in this paper is to present a hands-free interface (HFI that can be customized to the varying needs of EPW users with appropriate mapping between the users' degrees of freedom and EPW controls. EPW users with different impairment types must learn how to operate a wheelchair with their residual body motions. EPW interfaces are often customized to fit their needs. An HFI utilizes the signals generated by the user's voluntary shoulder and elbow movements and translates them into an EPW control scheme. We examine the correlation of kinematics that occur during moderately paced repetitive elbow and shoulder movements for a range of motion. The output of upper-limb movements (shoulder and elbows was tested on six participants, and compared with an output of a precision position tracking (PPT optical system for validation. We find strong correlations between the HFI signal counts and PPT optical system during different upper-limb movements (ranged from r = 0.86 to 0.94. We also tested the HFI performance in driving the EPW in a virtual reality environment on a spinal-cord-injured (SCI patient. The results showed that the HFI was able to adapt and translate the residual mobility of the SCI patient into efficient control commands within a week's training. The results are encouraging for the development of more efficient HFIs, especially for wheelchair users.

  2. Effectiveness of a nonrinse, alcohol-free antiseptic hand wash.

    Science.gov (United States)

    Moadab, A; Rupley, K F; Wadhams, P

    2001-06-01

    This study evaluated the efficacy of a novel surfactant, allantoin, and benzalkonium chloride hand sanitizer using the US Food and Drug Administration's method for testing antiseptic hand washes that podiatric physicians and other health-care personnel use. The alcohol-free product, HandClens, was compared with an alcohol-based product, Purell. Independent researchers from the California College of Podiatric Medicine conducted the study using 40 volunteer students from the class of 2001. The results show that HandClens outperformed Purell and met the regulatory requirements for a hand sanitizer. Purell failed as an antimicrobial hand wash and was less effective than a control soap used in the study.

  3. Testing a new alcohol-free hand sanitizer to combat infection.

    Science.gov (United States)

    Dyer, D L; Gerenraich, K B; Wadhams, P S

    1998-08-01

    Universal precautions require that perioperative health care personnel wash their hand before and after all patient contact. Time constraints, however, can make adhering to universal precautions, including proper hand washing, difficult. Some perioperative health care workers, therefore, routinely use rise-free hand sanitizers to supplement normal hand washing. This study evaluated immediate and persistent antimicrobial effectiveness of two alcohol--containing hand sanitizers and a novel surfactant, allantoin, benzalkonium chloride (SAB) hand sanitizer using a federally approved effectiveness protocol. Results indicate that all three products were equally effective after a single application. After repeated use, the alcohol-containing sanitizers did not meet federal performance standards, and the alcohol-free sanitizer did. These properties and others illustrated in this article indicate that the nonflammable, alcohol-free SAB hand sanitizer is the most favorable of the rise-free hand sanitizer formulas for normal hand washing.

  4. Position calibration of a 3-DOF hand-controller with hybrid structure

    Science.gov (United States)

    Zhu, Chengcheng; Song, Aiguo

    2017-09-01

    A hand-controller is a human-robot interactive device, which measures the 3-DOF (Degree of Freedom) position of the human hand and sends it as a command to control robot movement. The device also receives 3-DOF force feedback from the robot and applies it to the human hand. Thus, the precision of 3-DOF position measurements is a key performance factor for hand-controllers. However, when using a hybrid type 3-DOF hand controller, various errors occur and are considered originating from machining and assembly variations within the device. This paper presents a calibration method to improve the position tracking accuracy of hybrid type hand-controllers by determining the actual size of the hand-controller parts. By re-measuring and re-calibrating this kind of hand-controller, the actual size of the key parts that cause errors is determined. Modifying the formula parameters with the actual sizes, which are obtained in the calibrating process, improves the end position tracking accuracy of the device.

  5. Getting nowhere fast: trade-off between speed and precision in training to execute image-guided hand-tool movements

    Directory of Open Access Journals (Sweden)

    Anil Ufuk Batmaz

    2016-11-01

    Full Text Available Abstract Background The speed and precision with which objects are moved by hand or hand-tool interaction under image guidance depend on a specific type of visual and spatial sensorimotor learning. Novices have to learn to optimally control what their hands are doing in a real-world environment while looking at an image representation of the scene on a video monitor. Previous research has shown slower task execution times and lower performance scores under image-guidance compared with situations of direct action viewing. The cognitive processes for overcoming this drawback by training are not yet understood. Methods We investigated the effects of training on the time and precision of direct view versus image guided object positioning on targets of a Real-world Action Field (RAF. Two men and two women had to learn to perform the task as swiftly and as precisely as possible with their dominant hand, using a tool or not and wearing a glove or not. Individuals were trained in sessions of mixed trial blocks with no feed-back. Results As predicted, image-guidance produced significantly slower times and lesser precision in all trainees and sessions compared with direct viewing. With training, all trainees get faster in all conditions, but only one of them gets reliably more precise in the image-guided conditions. Speed-accuracy trade-offs in the individual performance data show that the highest precision scores and steepest learning curve, for time and precision, were produced by the slowest starter. Fast starters produced consistently poorer precision scores in all sessions. The fastest starter showed no sign of stable precision learning, even after extended training. Conclusions Performance evolution towards optimal precision is compromised when novices start by going as fast as they can. The findings have direct implications for individual skill monitoring in training programmes for image-guided technology applications with human operators.

  6. Clinical evaluation of the FreeStyle Precision Pro system.

    Science.gov (United States)

    Brazg, Ronald; Hughes, Kristen; Martin, Pamela; Coard, Julie; Toffaletti, John; McDonnell, Elizabeth; Taylor, Elizabeth; Farrell, Lausanne; Patel, Mona; Ward, Jeanne; Chen, Ting; Alva, Shridhara; Ng, Ronald

    2013-06-05

    A new version of international standard (ISO 15197) and CLSI Guideline (POCT12) with more stringent accuracy criteria are near publication. We evaluated the glucose test performance of the FreeStyle Precision Pro system, a new blood glucose monitoring system (BGMS) designed to enhance accuracy for point-of-care testing (POCT). Precision, interference and system accuracy with 503 blood samples from capillary, venous and arterial sources were evaluated in a multicenter study. Study results were analyzed and presented in accordance with the specifications and recommendations of the final draft ISO 15197 and the new POCT12. The FreeStyle Precision Pro system demonstrated acceptable precision (CV FreeStyle Precision Pro system met the tighter accuracy requirements, providing a means for enhancing accuracy for point-of-care blood glucose monitoring. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Alcohol-free instant hand sanitizer reduces elementary school illness absenteeism.

    Science.gov (United States)

    Dyer, D L; Shinder, A; Shinder, F

    2000-10-01

    BACKGROUND AND HYPOTHESES: A substantial percentage of school absenteeism among children is related to transmissible infection. Rates of transmission can be reduced by hand washing with soap and water, but such washing occurs infrequently. This study tested whether an alcohol-free instant hand sanitizer (CleanHands) could reduce illness absenteeism in school-age children. A 10-week, open-label, crossover study was performed on 420 elementary school-age children (ages 5-12). Students were given a brief orientation immediately prior to the start of the study on the relationship of germs, illness, and hand washing. Each student in the treatment group then received the test product in individual bottles, with instructions to apply one to two sprays to the hands after coming into the classroom, before eating, and after using the restroom, in addition to their normal hand washing with soap and water. The control group was instructed to continue hand washing as normal with non-medicated soap. After 4 weeks of treatment and a 2-week wash-out period, the control and experimental groups were reversed. Data gathered on absenteeism were classified as gastrointestinal or respiratory related and normalized for nonillness-related absenteeism and school holidays. Compared to the hand washing-only control group, students using CleanHands were found to have 41.9% fewer illness-related absence days, representing a 28.9% and a 49.7% drop in gastrointestinal- and respiratory-related illnesses, respectively. Likewise, absence incidence decreased by 31.7%, consisting of a 44.2% and 50.2% decrease in incidence of gastrointestinal- and respiratory-related illnesses, respectively. No adverse events were reported during the study. Daily use of the instant hand sanitizer was associated with significantly lower rates of illness-related absenteeism.

  8. Research of a New 6-Dof Force Feedback Hand Controller System

    Directory of Open Access Journals (Sweden)

    Xin Gao

    2014-01-01

    Full Text Available The field of teleoperation with force telepresence has expanded its scope to include manipulation at different scales and in virtual worlds, and the key component of which is force feedback hand controller. This paper presents a novel force feedback hand controller system, including a 3-dof translational and 3-dof rotational hand controllers, respectively, to implement position and posture teleoperation of the robot end effector. The 3-dof translational hand controller adopts innovative three-axes decoupling structure based on the linear motor; the 3-dof rotational hand controller adopts serial mechanism based on three-axes intersecting at one point, improving its overall stiffness. Based on the kinematics, statics, and dynamics analyses for two platforms separately, the system applies big closed-loop force control method based on the zero force/torque, improving the feedback force/torque accuracy effectively. Experimental results show that self-developed 6-dof force feedback hand controller has good mechanical properties. The translational hand controller has the following advantages: simple kinematics solver, fast dynamic response, and better than 0.05 mm accuracy of three-axis end positioning, while the advantages of the rotational hand controller are wide turning space, larger than 1 Nm feedback, greater than 180 degrees of operating space of three axes, respectively, and high operation precision.

  9. Hand Motion-Based Remote Control Interface with Vibrotactile Feedback for Home Robots

    Directory of Open Access Journals (Sweden)

    Juan Wu

    2013-06-01

    Full Text Available This paper presents the design and implementation of a hand-held interface system for the locomotion control of home robots. A handheld controller is proposed to implement hand motion recognition and hand motion-based robot control. The handheld controller can provide a ‘connect-and-play’ service for the users to control the home robot with visual and vibrotactile feedback. Six natural hand gestures are defined for navigating the home robots. A three-axis accelerometer is used to detect the hand motions of the user. The recorded acceleration data are analysed and classified to corresponding control commands according to their characteristic curves. A vibration motor is used to provide vibrotactile feedback to the user when an improper operation is performed. The performances of the proposed hand motion-based interface and the traditional keyboard and mouse interface have been compared in robot navigation experiments. The experimental results of home robot navigation show that the success rate of the handheld controller is 13.33% higher than the PC based controller. The precision of the handheld controller is 15.4% more than that of the PC and the execution time is 24.7% less than the PC based controller. This means that the proposed hand motion-based interface is more efficient and flexible.

  10. Dynamical Coordination of Hand Intrinsic Muscles for Precision Grip in Diabetes Mellitus.

    Science.gov (United States)

    Li, Ke; Wei, Na; Cheng, Mei; Hou, Xingguo; Song, Jun

    2018-03-12

    This study investigated the effects of diabetes mellitus (DM) on dynamical coordination of hand intrinsic muscles during precision grip. Precision grip was tested using a custom designed apparatus with stable and unstable loads, during which the surface electromyographic (sEMG) signals of the abductor pollicis brevis (APB) and first dorsal interosseous (FDI) were recorded simultaneously. Recurrence quantification analysis (RQA) was applied to quantify the dynamical structure of sEMG signals of the APB and FDI; and cross recurrence quantification analysis (CRQA) was used to assess the intermuscular coupling between the two intrinsic muscles. This study revealed that the DM altered the dynamical structure of muscle activation for the FDI and the dynamical intermuscular coordination between the APB and FDI during precision grip. A reinforced feedforward mechanism that compensates the loss of sensory feedbacks in DM may be responsible for the stronger intermuscular coupling between the APB and FDI muscles. Sensory deficits in DM remarkably decreased the capacity of online motor adjustment based on sensory feedback, rendering a lower adaptability to the uncertainty of environment. This study shed light on inherent dynamical properties underlying the intrinsic muscle activation and intermuscular coordination for precision grip and the effects of DM on hand sensorimotor function.

  11. Training manual for precision hand deburring, Part 3

    Energy Technology Data Exchange (ETDEWEB)

    Gillespie, L.K.

    1981-03-01

    This publication is Part 3 of a 4 part training manual to be used by machinist trainees, production workers, and others removing burrs from precision miniature parts. The manuals are written to be self-teaching and are intended to be used with two hours of training each day along with six additional hours of bench work in deburring. This part describes mounted stones, scrapers, hand stones, abrasive filled rubber and cotton tools, abrasive paper products, felt bobs and lapping compounds, mandrels and arbors, miscellaneous tools, personal techniques for assuring quality, cleaning parts, and deburring gears and plastic parts.

  12. Precision digital control systems

    Science.gov (United States)

    Vyskub, V. G.; Rozov, B. S.; Savelev, V. I.

    This book is concerned with the characteristics of digital control systems of great accuracy. A classification of such systems is considered along with aspects of stabilization, programmable control applications, digital tracking systems and servomechanisms, and precision systems for the control of a scanning laser beam. Other topics explored are related to systems of proportional control, linear devices and methods for increasing precision, approaches for further decreasing the response time in the case of high-speed operation, possibilities for the implementation of a logical control law, and methods for the study of precision digital control systems. A description is presented of precision automatic control systems which make use of electronic computers, taking into account the existing possibilities for an employment of computers in automatic control systems, approaches and studies required for including a computer in such control systems, and an analysis of the structure of automatic control systems with computers. Attention is also given to functional blocks in the considered systems.

  13. Quality control of structural MRI images applied using FreeSurfer - a hands-on workflow to rate motion artifacts

    Directory of Open Access Journals (Sweden)

    Lea Luise Backhausen

    2016-12-01

    Full Text Available In structural magnetic resonance imaging motion artifacts are common, especially when not scanning healthy young adults. It has been shown that motion affects the analysis with automated image-processing techniques (e.g. FreeSurfer. This can bias results. Several developmental and adult studies have found reduced volume and thickness of gray matter due to motion artifacts. Thus, quality control is necessary in order to ensure an acceptable level of quality and to define exclusion criteria of images (i.e. determine participants with most severe artifacts. However, information about the quality control workflow and image exclusion procedure is largely lacking in the current literature and the existing rating systems differ. Here we propose a stringent workflow of quality control steps during and after acquisition of T1-weighted images, which enables researchers dealing with populations that are typically affected by motion artifacts to enhance data quality and maximize sample sizes. As an underlying aim we established a thorough quality control rating system for T1-weighted images and applied it to the analysis of developmental clinical data using the automated processing pipeline FreeSurfer. This hands-on workflow and quality control rating system will aid researchers in minimizing motion artifacts in the final data set, and therefore enhance the quality of structural magnetic resonance imaging studies.

  14. A community-randomised controlled trial promoting waterless hand sanitizer and handwashing with soap, Dhaka, Bangladesh.

    Science.gov (United States)

    Luby, Stephen P; Kadir, Mohammad Abdul; Yushuf Sharker, M A; Yeasmin, Farzana; Unicomb, Leanne; Sirajul Islam, M

    2010-12-01

    To pilot two intensive hand hygiene promotion interventions, one using soap and one using a waterless hand sanitizer, in low-income housing compounds in Dhaka, Bangladesh and assess subsequent changes in handwashing behaviour and hand microbiology. Fieldworkers randomized 30 housing compounds: 10 received handwashing promotion with free soap, 10 received handwashing promotion with free waterless hand sanitizer and 10 were non-intervention controls. Fieldworkers assessed handwashing behaviour by structured observation and collected hand rinse specimens. At baseline, compound residents washed their hands with soap 26% of the time after defecation and 30% after cleaning a child's anus but hands with soap after faecal contact (85-91%), before preparing food (26%) and before eating (26%). Compounds that received waterless hand sanitizer cleansed their hands more commonly than control compounds that used soap (10.4%vs. 2.3%), but less commonly than soap intervention compounds used soap (25%). Post-intervention hand rinse samples from soap and sanitizer compounds had lower concentrations of faecal indicator bacteria compared with baseline and control compounds. Waterless hand sanitizer was readily adopted by this low-income community and reduced hand contamination but did not improve the frequency of handwashing compared with soap. Future deployments of waterless hand sanitizers may improve hand hygiene more effectively by targeting settings where soap and water is unavailable. © 2010 Blackwell Publishing Ltd.

  15. Development of five-finger robotic hand using master-slave control for hand-assisted laparoscopic surgery.

    Science.gov (United States)

    Yoshida, Koki; Yamada, Hiroshi; Kato, Ryu; Seki, Tatsuya; Yokoi, Hiroshi; Mukai, Masaya

    2016-08-01

    This study aims to develop a robotic hand as a substitute for a surgeon's hand in hand-assisted laparoscopic surgery (HALS). We determined the requirements for the proposed hand from a surgeon's motions in HALS. We identified four basic behaviors: "power grasp," "precision grasp," "open hand for exclusion," and "peace sign for extending peritoneum." The proposed hand had the minimum necessary DOFs for performing these behaviors, five fingers as in a human's hand, a palm that can be folded when a surgeon inserts the hand into the abdomen, and an arm for adjusting the hand's position. We evaluated the proposed hand based on a performance test and a physician's opinions, and we confirmed that it can grasp organs.

  16. A Control Strategy with Tactile Perception Feedback for EMG Prosthetic Hand

    Directory of Open Access Journals (Sweden)

    Changcheng Wu

    2015-01-01

    Full Text Available To improve the control effectiveness and make the prosthetic hand not only controllable but also perceivable, an EMG prosthetic hand control strategy was proposed in this paper. The control strategy consists of EMG self-learning motion recognition, backstepping controller with stiffness fuzzy observation, and force tactile representation. EMG self-learning motion recognition is used to reduce the influence on EMG signals caused by the uncertainty of the contacting position of the EMG sensors. Backstepping controller with stiffness fuzzy observation is used to realize the position control and grasp force control. Velocity proportional control in free space and grasp force tracking control in restricted space can be realized by the same controller. The force tactile representation helps the user perceive the states of the prosthetic hand. Several experiments were implemented to verify the effect of the proposed control strategy. The results indicate that the proposed strategy has effectiveness. During the experiments, the comments of the participants show that the proposed strategy is a better choice for amputees because of the improved controllability and perceptibility.

  17. Effects of a Driver Cellphone Ban on Overall, Handheld, and Hands-Free Cellphone Use While Driving: New Evidence from Canada.

    Science.gov (United States)

    Carpenter, Christopher S; Nguyen, Hai V

    2015-11-01

    We provide new evidence on the effects of increasingly common driver cellphone bans on self-reported overall, handheld, and hands-free cellphone use while driving by studying Ontario, Canada, which instituted a 3-month education campaign in November 2009 followed by a binding driver cellphone ban in February 2010. Using residents of Alberta as a control group in a difference-in-differences framework, we find visual and regression-based evidence that Ontario's cellphone ban significantly reduced overall and handheld cellphone use. We also find that the policies significantly increased hands-free cellphone use. The reductions in overall and handheld use are driven exclusively by women, whereas the increases in hands-free use are much larger for men. Our results provide the first direct evidence that cellphone bans have the unintended effect of inducing substitution to hands-free devices. Copyright © 2014 John Wiley & Sons, Ltd.

  18. Precise intraoperative location of gastrointestinal bleeding with a hand-held counter. Work in progress

    International Nuclear Information System (INIS)

    Williamson, M.R.; Boyd, C.M.; McGuire, E.L.

    1986-01-01

    The nuclear medicine bleeding scan is frequently insufficient to locate sites of bleeding precisely, in spite of its great sensitivity. A small, hand-held Geiger-Mueller counter, placed directly on exposed intestine in the operating room, enables precise location of the probable bleeding site. In three patients, the technique allowed a minimal amount of intestine to be resected, distinguished between large- and small-intestinal hemorrhage, and eliminated other foci as sites of bleeding.A

  19. Synaptic and functional linkages between spinal premotor interneurons and hand-muscle activity during precision grip

    Directory of Open Access Journals (Sweden)

    Tomohiko eTakei

    2013-04-01

    Full Text Available Grasping is a highly complex movement that requires the coordination of a number of hand joints and muscles. Previous studies showed that spinal premotor interneurons (PreM-INs in the primate cervical spinal cord have divergent synaptic effects on hand motoneurons and that they might contribute to hand-muscle synergies. However, the extent to which these PreM-IN synaptic connections functionally contribute to modulating hand-muscle activity is not clear. In this paper, we explored the contribution of spinal PreM-INs to hand-muscle activation by quantifying the synaptic linkage (SL and functional linkage (FL of the PreM-INs with hand-muscle activities. The activity of 23 PreM-INs was recorded from the cervical spinal cord (C6–T1, with EMG signals measured simultaneously from hand and arm muscles in two macaque monkeys performing a precision grip task. Spike-triggered averages (STAs of rectified EMGs were compiled for 456 neuron–muscle pairs; 63 pairs showed significant post-spike effects (i.e., SL. Conversely, 231 of 456 pairs showed significant cross-correlations between the IN firing rate and rectified EMG (i.e., FL. Importantly, a greater proportion of the neuron–muscle pairs with SL showed FL (43/63 pairs, 68% compared with the pairs without SL (203/393, 52%, and the presence of SL was significantly associated with that of FL. However, a significant number of pairs had SL without FL (SL∩!FL, n = 20 or FL without SL (!SL∩FL, n = 203, and the proportions of these incongruities exceeded the number expected by chance. These results suggested that spinal PreM-INs function to significantly modulate hand-muscle activity during precision grip, but the contribution of other neural structures is also needed to recruit an adequate combination of hand-muscle motoneurons.

  20. How the impact of median neuropathy on sensorimotor control capability of hands for diabetes: an achievable assessment from functional perspectives.

    Directory of Open Access Journals (Sweden)

    Haw-Yen Chiu

    Full Text Available To comprehend the sensorimotor control ability in diabetic hands, this study investigated the sensation, motor function and precision pinch performances derived from a pinch-holding-up activity (PHUA test of the hands of diabetic patients and healthy subjects. The precision, sensitivity and specificity of the PHUA test in the measurements of diabetic patients were also analyzed. We hypothesized that the diabetic hands would have impacts on the sensorimotor functions of the hand performances under functionally quantitative measurements. One hundred and fifty-nine patients with clinically defined diabetes mellitus (DM and 95 age- and gender-matched healthy controls were included. Semmes-Weinstein monofilament (SWM, static and moving two-point discrimination (S2PD and M2PD, maximal pinch strength and precision pinch performance tests were conducted to evaluate the sensation, motor and sensorimotor status of the recruited hands. The results showed that there were significant differences (all p<0.05 in SWM, S2PD, M2PD and maximum pinch strength between the DM and control groups. A higher force ratio in the DM patients than in the controls (p<0.001 revealed a poor ability of pinch force adjustment in the DM patients. The percentage of maximal pinch strength was also significantly different (p<0.001 between the DM and control groups. The sensitivity, specificity and area under the receiver operating characteristic curve were 0.85, 0.51, and 0.724, respectively, for the PHUA test. Statistically significant degradations in sensory and motor functions and sensorimotor control ability were observed in the hands of the diabetic patients. The PHUA test could be feasibly used as a clinical tool to determine the sensorimotor function of the hands of diabetic patients from a functional perspective.

  1. Dorsal hand coverage with free serratus fascia flap

    DEFF Research Database (Denmark)

    Fotopoulos, Peter; Holmer, Per; Leicht, Pernille

    2003-01-01

    in the flap, leaving the long thoracic nerve intact on the serratus muscle. Coverage of the flap with split-thickness skin graft is done immediately. The free serratus fascia flap is an ideal flap for dorsal hand coverage when the extensor tendons are exposed, especially because of low donor-site morbidity....

  2. Reduction of illness absenteeism in elementary schools using an alcohol-free instant hand sanitizer.

    Science.gov (United States)

    White, C G; Shinder, F S; Shinder, A L; Dyer, D L

    2001-10-01

    Hand washing is the most effective way to prevent the spread of communicable disease. The purpose of this double-blind, placebo-controlled study was to assess whether an alcohol-free, instant hand sanitizer containing surfactants, allantoin, and benzalkonium chloride could reduce illness absenteeism in a population of 769 elementary school children and serve as an effective alternative when regular soap and water hand washing was not readily available. Prior to the study, students were educated about proper hand washing technique, the importance of hand washing to prevent transmission of germs, and the relationship between germs and illnesses. Children in kindergarten through the 6th grade (ages 5-12) were assigned to the active or placebo hand-sanitizer product and instructed to use the product at scheduled times during the day and as needed after coughing or sneezing. Data on illness absenteeism were tracked. After 5 weeks, students using the active product were 33% less likely to have been absent because of illness when compared with the placebo group.

  3. High-precision measurement of the 19Ne half-life and implications for right-handed weak currents.

    Science.gov (United States)

    Triambak, S; Finlay, P; Sumithrarachchi, C S; Hackman, G; Ball, G C; Garrett, P E; Svensson, C E; Cross, D S; Garnsworthy, A B; Kshetri, R; Orce, J N; Pearson, M R; Tardiff, E R; Al-Falou, H; Austin, R A E; Churchman, R; Djongolov, M K; D'Entremont, R; Kierans, C; Milovanovic, L; O'Hagan, S; Reeve, S; Sjue, S K L; Williams, S J

    2012-07-27

    We report a precise determination of the (19)Ne half-life to be T(1/2)=17.262±0.007 s. This result disagrees with the most recent precision measurements and is important for placing bounds on predicted right-handed interactions that are absent in the current standard model. We are able to identify and disentangle two competing systematic effects that influence the accuracy of such measurements. Our findings prompt a reassessment of results from previous high-precision lifetime measurements that used similar equipment and methods.

  4. High-Precision Measurement of the Ne19 Half-Life and Implications for Right-Handed Weak Currents

    Science.gov (United States)

    Triambak, S.; Finlay, P.; Sumithrarachchi, C. S.; Hackman, G.; Ball, G. C.; Garrett, P. E.; Svensson, C. E.; Cross, D. S.; Garnsworthy, A. B.; Kshetri, R.; Orce, J. N.; Pearson, M. R.; Tardiff, E. R.; Al-Falou, H.; Austin, R. A. E.; Churchman, R.; Djongolov, M. K.; D'Entremont, R.; Kierans, C.; Milovanovic, L.; O'Hagan, S.; Reeve, S.; Sjue, S. K. L.; Williams, S. J.

    2012-07-01

    We report a precise determination of the Ne19 half-life to be T1/2=17.262±0.007s. This result disagrees with the most recent precision measurements and is important for placing bounds on predicted right-handed interactions that are absent in the current standard model. We are able to identify and disentangle two competing systematic effects that influence the accuracy of such measurements. Our findings prompt a reassessment of results from previous high-precision lifetime measurements that used similar equipment and methods.

  5. Pediatric mandibular fractures: a free hand technique.

    Science.gov (United States)

    Davison, S P; Clifton, M S; Davison, M N; Hedrick, M; Sotereanos, G

    2001-01-01

    The treatment of pediatric mandibular fractures is rare, controversial, and complicated by mixed dentition. To determine if open mandibular fracture repair with intraoral and extraoral rigid plate placement, after free hand occlusal and bone reduction, without intermaxillary fixation (IMF), is appropriate and to discuss postoperative advantages, namely, maximal early return of function and minimal oral hygiene issues. A group of 29 pediatric patients with a mandibular fracture were examined. Twenty pediatric patients (13 males and 7 females) with a mean age of 9 years (age range, 1-17 years) were treated using IMF. All patients were treated by the same surgeon (G.S.). Surgical time for plating was reduced by 1 hour, the average time to place patients in IMF. The patients who underwent open reduction internal fixation without IMF ate a soft mechanical diet by postoperative day 3 compared with postoperative day 16 for those who underwent IMF. Complication rates related to fixation technique were comparable at 20% for those who did not undergo IMF and 33% for those who did. We believe that free hand reduction is a valuable technique to reduce operative time for pediatric mandibular fractures. It maximizes return to function while minimizing the oral hygiene issues and hardware removal of intermaxillary function.

  6. A systematic review of the effectiveness of antimicrobial rinse-free hand sanitizers for prevention of illness-related absenteeism in elementary school children.

    Science.gov (United States)

    Meadows, Emily; Le Saux, Nicole

    2004-11-01

    Absenteeism due to communicable illness is a major problem encountered by North American elementary school children. Although handwashing is a proven infection control measure, barriers exist in the school environment, which hinder compliance to this routine. Currently, alternative hand hygiene techniques are being considered, and one such technique is the use of antimicrobial rinse-free hand sanitizers. A systematic review was conducted to examine the effectiveness of antimicrobial rinse-free hand sanitizer interventions in the elementary school setting. MEDLINE, EMBASE, Biological Abstract, CINAHL, HealthSTAR and Cochrane Controlled Trials Register were searched for both randomized and non-randomized controlled trials. Absenteeism due to communicable illness was the primary outcome variable. Six eligible studies, two of which were randomized, were identified (5 published studies, 1 published abstract). The quality of reporting was low. Due to a large amount of heterogeneity and low quality of reporting, no pooled estimates were calculated. There was a significant difference reported in favor of the intervention in all 5 published studies. The available evidence for the effectiveness of antimicrobial rinse-free hand sanitizer in the school environment is of low quality. The results suggest that the strength of the benefit should be interpreted with caution. Given the potential to reduce student absenteeism, teacher absenteeism, school operating costs, healthcare costs and parental absenteeism, a well-designed and analyzed trial is needed to optimize this hand hygiene technique.

  7. Haptic Feedback in Motor Hand Virtual Therapy Increases Precision and Generates Less Mental Workload

    Directory of Open Access Journals (Sweden)

    Cristina Ramírez-Fernández

    2015-10-01

    Full Text Available In this work we show that haptic feedback in upper limb motor therapy improves performance and generates a lower mental workload. To demonstrate this, two groups of participants (healthy adults and elders with hand motor problems used a low-cost haptic device (Novint Falcon and a non-robotic device (Leap Motion Controller. Participants conducted the same rehabilitation task by using a non-immersive virtual environment. Results show significant differences for all participants regarding precision on the use of the haptic feedback device. Additionally, participants in the older adult group demonstrated a lower mental workload while using the haptic device (Novint Falcon. Finally, qualitative results show that participants preferred to conduct their therapy exercises by using the haptic device, as they found it more useful, easier to use and easier to learn

  8. A systematic review of the effectiveness of antimicrobial rinse-free hand sanitizers for prevention of illness-related absenteeism in elementary school children

    Science.gov (United States)

    Meadows, Emily; Le Saux, Nicole

    2004-01-01

    Background Absenteeism due to communicable illness is a major problem encountered by North American elementary school children. Although handwashing is a proven infection control measure, barriers exist in the school environment, which hinder compliance to this routine. Currently, alternative hand hygiene techniques are being considered, and one such technique is the use of antimicrobial rinse-free hand sanitizers. Methods A systematic review was conducted to examine the effectiveness of antimicrobial rinse-free hand sanitizer interventions in the elementary school setting. MEDLINE, EMBASE, Biological Abstract, CINAHL, HealthSTAR and Cochrane Controlled Trials Register were searched for both randomized and non-randomized controlled trials. Absenteeism due to communicable illness was the primary outcome variable. Results Six eligible studies, two of which were randomized, were identified (5 published studies, 1 published abstract). The quality of reporting was low. Due to a large amount of heterogeneity and low quality of reporting, no pooled estimates were calculated. There was a significant difference reported in favor of the intervention in all 5 published studies. Conclusions The available evidence for the effectiveness of antimicrobial rinse-free hand sanitizer in the school environment is of low quality. The results suggest that the strength of the benefit should be interpreted with caution. Given the potential to reduce student absenteeism, teacher absenteeism, school operating costs, healthcare costs and parental absenteeism, a well-designed and analyzed trial is needed to optimize this hand hygiene technique. PMID:15518593

  9. A systematic review of the effectiveness of antimicrobial rinse-free hand sanitizers for prevention of illness-related absenteeism in elementary school children

    Directory of Open Access Journals (Sweden)

    Le Saux Nicole

    2004-11-01

    Full Text Available Abstract Background Absenteeism due to communicable illness is a major problem encountered by North American elementary school children. Although handwashing is a proven infection control measure, barriers exist in the school environment, which hinder compliance to this routine. Currently, alternative hand hygiene techniques are being considered, and one such technique is the use of antimicrobial rinse-free hand sanitizers. Methods A systematic review was conducted to examine the effectiveness of antimicrobial rinse-free hand sanitizer interventions in the elementary school setting. MEDLINE, EMBASE, Biological Abstract, CINAHL, HealthSTAR and Cochrane Controlled Trials Register were searched for both randomized and non-randomized controlled trials. Absenteeism due to communicable illness was the primary outcome variable. Results Six eligible studies, two of which were randomized, were identified (5 published studies, 1 published abstract. The quality of reporting was low. Due to a large amount of heterogeneity and low quality of reporting, no pooled estimates were calculated. There was a significant difference reported in favor of the intervention in all 5 published studies. Conclusions The available evidence for the effectiveness of antimicrobial rinse-free hand sanitizer in the school environment is of low quality. The results suggest that the strength of the benefit should be interpreted with caution. Given the potential to reduce student absenteeism, teacher absenteeism, school operating costs, healthcare costs and parental absenteeism, a well-designed and analyzed trial is needed to optimize this hand hygiene technique.

  10. The Anconeus Muscle Free Flap: Clinical Application to Lesions on the Hand

    Directory of Open Access Journals (Sweden)

    Byung-Joon Jeon

    2017-09-01

    Full Text Available Background It can be difficult to select an appropriate flap for various defects on the hand. Although defects of the hand usually must be covered with a skin flap, some defects require a flap with rich blood supply and adequate additive soft tissue volume. The authors present their experience with the anconeus muscle free flap in the reconstruction of various defects and the release of scar contractures of the hand. Methods Ten patients underwent reconstruction of the finger or release of the first web space using the anconeus muscle free flap from May 1998 to October 2013. Adequate bed preparations with thorough debridement or contracture release were performed. The entire anconeus muscle, located at the elbow superficially, was harvested, with the posterior recurrent interosseous artery as a pedicle. The defects were covered with a uniformly trimmed anconeus muscle free flap. Additional debulking of the flap and skin coverage using a split-thickness skin graft were performed 3 weeks after the first operation. Results The average flap size was 18.7 cm2 (range, 13.5–30 cm2. All flaps survived without significant complications. Vein grafts for overcoming a short pedicle were necessary in 4 cases. Conclusions The anconeus muscle free flap can be considered a reliable reconstructive option for small defects on the hand or contracture release of the web space, because it has relatively consistent anatomy, provides robust blood supply within the same operative field, and leads to no functional loss at the donor site.

  11. An EMG-Controlled Robotic Hand Exoskeleton for Bilateral Rehabilitation.

    Science.gov (United States)

    Leonardis, Daniele; Barsotti, Michele; Loconsole, Claudio; Solazzi, Massimiliano; Troncossi, Marco; Mazzotti, Claudio; Castelli, Vincenzo Parenti; Procopio, Caterina; Lamola, Giuseppe; Chisari, Carmelo; Bergamasco, Massimo; Frisoli, Antonio

    2015-01-01

    This paper presents a novel electromyography (EMG)-driven hand exoskeleton for bilateral rehabilitation of grasping in stroke. The developed hand exoskeleton was designed with two distinctive features: (a) kinematics with intrinsic adaptability to patient's hand size, and (b) free-palm and free-fingertip design, preserving the residual sensory perceptual capability of touch during assistance in grasping of real objects. In the envisaged bilateral training strategy, the patient's non paretic hand acted as guidance for the paretic hand in grasping tasks. Grasping force exerted by the non paretic hand was estimated in real-time from EMG signals, and then replicated as robotic assistance for the paretic hand by means of the hand-exoskeleton. Estimation of the grasping force through EMG allowed to perform rehabilitation exercises with any, non sensorized, graspable objects. This paper presents the system design, development, and experimental evaluation. Experiments were performed within a group of six healthy subjects and two chronic stroke patients, executing robotic-assisted grasping tasks. Results related to performance in estimation and modulation of the robotic assistance, and to the outcomes of the pilot rehabilitation sessions with stroke patients, positively support validity of the proposed approach for application in stroke rehabilitation.

  12. High-speed precision motion control

    CERN Document Server

    Yamaguchi, Takashi; Pang, Chee Khiang

    2011-01-01

    Written for researchers and postgraduate students in Control Engineering, as well as professionals in the Hard Disk Drive industry, this book discusses high-precision and fast servo controls in Hard Disk Drives (HDDs). The editors present a number of control algorithms that enable fast seeking and high precision positioning, and propose problems from commercial products, making the book valuable to researchers in HDDs. Each chapter is self contained, and progresses from concept to technique, present application examples that can be used within automotive, aerospace, aeronautical, and manufactu

  13. Hands-free administration of subjective workload scales: acceptability in a surgical training environment.

    Science.gov (United States)

    Carswell, C Melody; Lio, Cindy H; Grant, Russell; Klein, Martina I; Clarke, Duncan; Seales, W Brent; Strup, Stephen

    2010-12-01

    Subjective workload measures are usually administered in a visual-manual format, either electronically or by paper and pencil. However, vocal responses to spoken queries may sometimes be preferable, for example when experimental manipulations require continuous manual responding or when participants have certain sensory/motor impairments. In the present study, we evaluated the acceptability of the hands-free administration of two subjective workload questionnaires - the NASA Task Load Index (NASA-TLX) and the Multiple Resources Questionnaire (MRQ) - in a surgical training environment where manual responding is often constrained. Sixty-four undergraduates performed fifteen 90-s trials of laparoscopic training tasks (five replications of 3 tasks - cannulation, ring transfer, and rope manipulation). Half of the participants provided workload ratings using a traditional paper-and-pencil version of the NASA-TLX and MRQ; the remainder used a vocal (hands-free) version of the questionnaires. A follow-up experiment extended the evaluation of the hands-free version to actual medical students in a Minimally Invasive Surgery (MIS) training facility. The NASA-TLX was scored in 2 ways - (1) the traditional procedure using participant-specific weights to combine its 6 subscales, and (2) a simplified procedure - the NASA Raw Task Load Index (NASA-RTLX) - using the unweighted mean of the subscale scores. Comparison of the scores obtained from the hands-free and written administration conditions yielded coefficients of equivalence of r=0.85 (NASA-TLX) and r=0.81 (NASA-RTLX). Equivalence estimates for the individual subscales ranged from r=0.78 ("mental demand") to r=0.31 ("effort"). Both administration formats and scoring methods were equally sensitive to task and repetition effects. For the MRQ, the coefficient of equivalence for the hands-free and written versions was r=0.96 when tested on undergraduates. However, the sensitivity of the hands-free MRQ to task demands (

  14. Air Muscle Actuated Low Cost Humanoid Hand

    Directory of Open Access Journals (Sweden)

    Peter Scarfe

    2008-11-01

    Full Text Available The control of humanoid robot hands has historically been expensive due to the cost of precision actuators. This paper presents the design and implementation of a low-cost air muscle actuated humanoid hand developed at Curtin University of Technology. This hand offers 10 individually controllable degrees of freedom ranging from the elbow to the fingers, with overall control handled through a computer GUI. The hand is actuated through 20 McKibben-style air muscles, each supplied by a pneumatic pressure-balancing valve that allows for proportional control to be achieved with simple and inexpensive components. The hand was successfully able to perform a number of human-equivalent tasks, such as grasping and relocating objects.

  15. Air Muscle Actuated Low Cost Humanoid Hand

    Directory of Open Access Journals (Sweden)

    Peter Scarfe

    2006-06-01

    Full Text Available The control of humanoid robot hands has historically been expensive due to the cost of precision actuators. This paper presents the design and implementation of a low-cost air muscle actuated humanoid hand developed at Curtin University of Technology. This hand offers 10 individually controllable degrees of freedom ranging from the elbow to the fingers, with overall control handled through a computer GUI. The hand is actuated through 20 McKibben-style air muscles, each supplied by a pneumatic pressure-balancing valve that allows for proportional control to be achieved with simple and inexpensive components. The hand was successfully able to perform a number of human-equivalent tasks, such as grasping and relocating objects.

  16. Drag-Free Motion Control of Satellite for High-Precision Gravity Field Mapping

    DEFF Research Database (Denmark)

    Ziegler, Bent Lindvig; Blanke, Mogens

    2002-01-01

    High precision mapping of the geoid and the Earth's gravity field are of importance to a wide range of ongoing studies in areas like ocean circulation, solid Earth physics and ice sheet dynamics. Using a satellite in orbit around the Earth gives the opportunity to map the Earth's gravity field in 3...... will compromise measurement accuracy, unless they are accurately compensated by on-board thrusters. The paper concerns the design of a control system to performing such delicate drag compensation. A six degrees-of-freedom model for the satellite is developed with the model including dynamics of the satellite...

  17. Learning Is Better with the Hands Free: The Role of Posture in the Memory of Manipulable Objects.

    Directory of Open Access Journals (Sweden)

    Léo Dutriaux

    Full Text Available Grounded cognition proposes that memory shares processing resources with sensorimotor systems. The aim of the present study was to show that motor simulation participates in the conceptual representation of manipulable objects in long-term memory. In two experiments, lists of manipulable and nonmanipulable objects were presented. Participants were instructed to memorize the items while adopting different postures. In the control condition, they had to keep their hands at rest in front of them. In the interference condition, participants had to keep their hands crossed behind their back to make their hands less free for action. After each list, participants had to perform first a distractive task, and then an oral free recall. The results showed that the interfering posture produced a specific decrease in the recall of manipulable objects, but not of nonmanipulable ones. This decrease was similar when the items were presented as pictures (Experiment 1 or as words (Experiment 2, thus excluding a purely visual effect. These results provide strong evidence that the motor simulation plays a role in the memory trace of the object.

  18. Learning Is Better with the Hands Free: The Role of Posture in the Memory of Manipulable Objects.

    Science.gov (United States)

    Dutriaux, Léo; Gyselinck, Valérie

    2016-01-01

    Grounded cognition proposes that memory shares processing resources with sensorimotor systems. The aim of the present study was to show that motor simulation participates in the conceptual representation of manipulable objects in long-term memory. In two experiments, lists of manipulable and nonmanipulable objects were presented. Participants were instructed to memorize the items while adopting different postures. In the control condition, they had to keep their hands at rest in front of them. In the interference condition, participants had to keep their hands crossed behind their back to make their hands less free for action. After each list, participants had to perform first a distractive task, and then an oral free recall. The results showed that the interfering posture produced a specific decrease in the recall of manipulable objects, but not of nonmanipulable ones. This decrease was similar when the items were presented as pictures (Experiment 1) or as words (Experiment 2), thus excluding a purely visual effect. These results provide strong evidence that the motor simulation plays a role in the memory trace of the object.

  19. Shape-estimation of human hand using polymer flex sensor and study of its application to control robot arm

    International Nuclear Information System (INIS)

    Lee, Jin Hyuck; Kim, Dae Hyun

    2015-01-01

    Ultrasonic inspection robot systems have been widely researched and developed for the real-time monitoring of structures such as power plants. However, an inspection robot that is operated in a simple pattern has limitations in its application to various structures in a plant facility because of the diverse and complicated shapes of the inspection objects. Therefore, accurate control of the robot is required to inspect complicated objects with high-precision results. This paper presents the idea that the shape and movement information of an ultrasonic inspector's hand could be profitably utilized for the accurate control of robot. In this study, a polymer flex sensor was applied to monitor the shape of a human hand. This application was designed to intuitively control an ultrasonic inspection robot. The movement and shape of the hand were estimated by applying multiple sensors. Moreover, it was successfully shown that a test robot could be intuitively controlled based on the shape of a human hand estimated using polymer flex sensors.

  20. Shape-estimation of human hand using polymer flex sensor and study of its application to control robot arm

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Hyuck; Kim, Dae Hyun [Seoul National University of Technology, Seoul (Korea, Republic of)

    2015-02-15

    Ultrasonic inspection robot systems have been widely researched and developed for the real-time monitoring of structures such as power plants. However, an inspection robot that is operated in a simple pattern has limitations in its application to various structures in a plant facility because of the diverse and complicated shapes of the inspection objects. Therefore, accurate control of the robot is required to inspect complicated objects with high-precision results. This paper presents the idea that the shape and movement information of an ultrasonic inspector's hand could be profitably utilized for the accurate control of robot. In this study, a polymer flex sensor was applied to monitor the shape of a human hand. This application was designed to intuitively control an ultrasonic inspection robot. The movement and shape of the hand were estimated by applying multiple sensors. Moreover, it was successfully shown that a test robot could be intuitively controlled based on the shape of a human hand estimated using polymer flex sensors.

  1. Increased efficiency in the second-hand tire trade provides opportunity for dengue control.

    Science.gov (United States)

    Pliego Pliego, Emilene; Velázquez-Castro, Jorge; Eichhorn, Markus P; Fraguela Collar, Andrés

    2018-01-21

    Dengue fever is increasing in geographical range, spread by invasion of its vector mosquitoes. The trade in second-hand tires has been implicated as a factor in this process because they act as mobile reservoirs of mosquito eggs and larvae. Regional transportation of tires can create linkages between rural areas with dengue and disease-free urban areas, potentially giving rise to outbreaks even in areas with strong local control measures. In this work we sought to model the dynamics of mosquito transportation via the tire trade, in particular to predict its role in causing unexpected dengue outbreaks through vertical transmission of the virus across generations of mosquitoes. We also aimed to identify strategies for regulating the trade in second-hand tires, improving disease control. We created a mathematical model which captures the dynamics of dengue between rural and urban areas, taking into account the movement and storage time of tires, and mosquito diapause. We simulate a series of scenarios in which a mosquito population is introduced to a dengue-free area via movement of tires, either as single or multiple events, increasing the likelihood of a dengue outbreak. A persistent disease state can be induced regardless of whether urban conditions for an outbreak are met, and an existing endemic state can be enhanced by vector input. Finally we assess the potential for regulation of tire processing as a means of reducing the transmission of dengue fever using a specific case study from Puerto Rico. Our work demonstrates the importance of the second-hand tire trade in modulating the spread of dengue fever across regions, in particular its role in introducing dengue to disease-free areas. We propose that reduction of tire storage time and control of their movement can play a crucial role in containing dengue outbreaks. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Circuit For Control Of Electromechanical Prosthetic Hand

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1995-01-01

    Proposed circuit for control of electromechanical prosthetic hand derives electrical control signals from shoulder movements. Updated, electronic version of prosthesis, that includes two hooklike fingers actuated via cables from shoulder harness. Circuit built around favored shoulder harness, provides more dexterous movement, without incurring complexity of computer-controlled "bionic" or hydraulically actuated devices. Additional harness and potentiometer connected to similar control circuit mounted on other shoulder. Used to control stepping motor rotating hand about prosthetic wrist to one of number of angles consistent with number of digital outputs. Finger-control signals developed by circuit connected to first shoulder harness transmitted to prosthetic hand via sliprings at prosthetic wrist joint.

  3. Comparing handheld and hands-free cell phone usage behaviors while driving.

    Science.gov (United States)

    Soccolich, Susan A; Fitch, Gregory M; Perez, Miguel A; Hanowski, Richard J

    2014-01-01

    The goal of this study was to compare cell phone usage behaviors while driving across 3 types of cell phones: handheld (HH) cell phones, portable hands-free (PHF) cell phones, and integrated hands-free (IHF) cell phones. Naturalistic driving data were used to observe HH, PHF, and IHF usage behaviors in participants' own vehicles without any instructions or manipulations by researchers. In addition to naturalistic driving data, drivers provided their personal cell phone call records. Calls during driving were sampled and observed in naturalistically collected video. Calls were reviewed to identify cell phone type used for, and duration of, cell phone subtasks, non-cell phone secondary tasks, and other use behaviors. Drivers in the study self-identified as HH, PHF, or IHF users if they reported using that cell phone type at least 50% of the time. However, each sampled call was classified as HH, PHF, or IHF if the talking/listening subtask was conducted using that cell phone type, without considering the driver's self-reported group. Drivers with PHF or IHF systems also used HH cell phones (IHF group used HH cell phone in 53.2% of the interactions, PHF group used HH cell phone for 55.5% of interactions). Talking/listening on a PHF phone or an IHF phone was significantly longer than talking/listening on an HH phone (P phone call task for HH phones was significantly longer in duration than the end phone call task for PHF and IHF phones. Of all the non-cell phone-related secondary tasks, eating or drinking was found to occur significantly more often during IHF subtasks (0.58%) than in HH subtasks (0.15%). Drivers observed to reach for their cell phone mostly kept their cell phone in the cup holder (36.3%) or in their seat or lap (29.0% of interactions); however, some observed locations may have required drivers to move out of position. Hands-free cell phone technologies reduce the duration of cell phone visual-manual tasks compared to handheld cell phones. However

  4. Hand-to-Hand Model for Bioelectrical Impedance Analysis to Estimate Fat Free Mass in a Healthy Population

    Directory of Open Access Journals (Sweden)

    Hsueh-Kuan Lu

    2016-10-01

    Full Text Available This study aimed to establish a hand-to-hand (HH model for bioelectrical impedance analysis (BIA fat free mass (FFM estimation by comparing with a standing position hand-to-foot (HF BIA model and dual energy X-ray absorptiometry (DXA; we also verified the reliability of the newly developed model. A total of 704 healthy Chinese individuals (403 men and 301 women participated. FFM (FFMDXA reference variables were measured using DXA and segmental BIA. Further, regression analysis, Bland–Altman plots, and cross-validation (2/3 participants as the modeling group, 1/3 as the validation group; three turns were repeated for validation grouping were conducted to compare tests of agreement with FFMDXA reference variables. In male participants, the hand-to-hand BIA model estimation equation was calculated as follows: FFMmHH = 0.537 h2/ZHH − 0.126 year + 0.217 weight + 18.235 (r2 = 0.919, standard estimate of error (SEE = 2.164 kg, n = 269. The mean validated correlation coefficients and limits of agreement (LOAs of the Bland–Altman analysis of the calculated values for FFMmHH and FFMDXA were 0.958 and −4.369–4.343 kg, respectively, for hand-to-foot BIA model measurements for men; the FFM (FFMmHF and FFMDXA were 0.958 and −4.356–4.375 kg, respectively. The hand-to-hand BIA model estimating equation for female participants was FFMFHH = 0.615 h2/ZHH − 0.144 year + 0.132 weight + 16.507 (r2 = 0.870, SEE = 1.884 kg, n = 201; the three mean validated correlation coefficient and LOA for the hand-to-foot BIA model measurements for female participants (FFMFHH and FFMDXA were 0.929 and −3.880–3.886 kg, respectively. The FFMHF and FFMDXA were 0.942 and −3.511–3.489 kg, respectively. The results of both hand-to-hand and hand-to-foot BIA models demonstrated similar reliability, and the hand-to-hand BIA models are practical for assessing FFM.

  5. Hand-to-Hand Model for Bioelectrical Impedance Analysis to Estimate Fat Free Mass in a Healthy Population.

    Science.gov (United States)

    Lu, Hsueh-Kuan; Chiang, Li-Ming; Chen, Yu-Yawn; Chuang, Chih-Lin; Chen, Kuen-Tsann; Dwyer, Gregory B; Hsu, Ying-Lin; Chen, Chun-Hao; Hsieh, Kuen-Chang

    2016-10-21

    This study aimed to establish a hand-to-hand (HH) model for bioelectrical impedance analysis (BIA) fat free mass (FFM) estimation by comparing with a standing position hand-to-foot (HF) BIA model and dual energy X-ray absorptiometry (DXA); we also verified the reliability of the newly developed model. A total of 704 healthy Chinese individuals (403 men and 301 women) participated. FFM (FFM DXA ) reference variables were measured using DXA and segmental BIA. Further, regression analysis, Bland-Altman plots, and cross-validation (2/3 participants as the modeling group, 1/3 as the validation group; three turns were repeated for validation grouping) were conducted to compare tests of agreement with FFM DXA reference variables. In male participants, the hand-to-hand BIA model estimation equation was calculated as follows: FFM m HH = 0.537 h²/Z HH - 0.126 year + 0.217 weight + 18.235 ( r ² = 0.919, standard estimate of error (SEE) = 2.164 kg, n = 269). The mean validated correlation coefficients and limits of agreement (LOAs) of the Bland-Altman analysis of the calculated values for FFM m HH and FFM DXA were 0.958 and -4.369-4.343 kg, respectively, for hand-to-foot BIA model measurements for men; the FFM (FFM m HF ) and FFM DXA were 0.958 and -4.356-4.375 kg, respectively. The hand-to-hand BIA model estimating equation for female participants was FFM F HH = 0.615 h²/Z HH - 0.144 year + 0.132 weight + 16.507 ( r ² = 0.870, SEE = 1.884 kg, n = 201); the three mean validated correlation coefficient and LOA for the hand-to-foot BIA model measurements for female participants (FFM F HH and FFM DXA ) were 0.929 and -3.880-3.886 kg, respectively. The FFM HF and FFM DXA were 0.942 and -3.511-3.489 kg, respectively. The results of both hand-to-hand and hand-to-foot BIA models demonstrated similar reliability, and the hand-to-hand BIA models are practical for assessing FFM.

  6. Visual control improves the accuracy of hand positioning in Huntington’s disease

    Directory of Open Access Journals (Sweden)

    Emilia J. Sitek

    2017-08-01

    Full Text Available Background: The study aimed at demonstrating dependence of visual feedback during hand and finger positioning task performance among Huntington’s disease patients in comparison to patients with Parkinson’s disease and cervical dystonia. Material and methods: Eighty-nine patients participated in the study (23 with Huntington’s disease, 25 with Parkinson’s disease with dyskinesias, 21 with Parkinson’s disease without dyskinesias, and 20 with cervical dystonia, scoring ≥20 points on Mini-Mental State Examination in order to assure comprehension of task instructions. Neurological examination comprised of the motor section from the Unified Huntington’s Disease Rating Scale for Huntington’s disease, the Unified Parkinson’s Disease Rating Scale Part II–IV for Parkinson’s disease and the Toronto Western Spasmodic Torticollis Rating Scale for cervical dystonia. In order to compare hand position accuracy under visually controlled and blindfolded conditions, the patient imitated each of the 10 examiner’s hand postures twice, once under the visual control condition and once with no visual feedback provided. Results: Huntington’s disease patients imitated examiner’s hand positions less accurately under blindfolded condition in comparison to Parkinson’s disease without dyskinesias and cervical dystonia participants. Under visually controlled condition there were no significant inter-group differences. Conclusions: Huntington’s disease patients exhibit higher dependence on visual feedback while performing motor tasks than Parkinson’s disease and cervical dystonia patients. Possible improvement of movement precision in Huntington’s disease with the use of visual cues could be potentially useful in the patients’ rehabilitation.

  7. Evaluation of Hands-Free Devices for the Display of Maintenance Procedures

    Science.gov (United States)

    Whitmore, Mihriban; Hoffman, Ronald B.; Litaker, Harry, Jr.; Solem, Jody; Holden, Kritina; Twyford, Evan; Conlee, Carl

    2007-01-01

    Over the past year, NASA's focus has turned to crewed long duration and exploration missions. On these journeys, crewmembers will be required to execute thousands of procedures to maintain life support systems, check out space suits, conduct science experiments, and perform medical exams. To support the many complex tasks crewmembers undertake in microgravity, NASA is interested in providing crewmembers a hands-free work environment to promote more efficient operations. The overarching objective is to allow crewmembers to use both of their hands for tasks related to their mission, versus holding a paper manual or interacting with a display. The use of advanced, hands-free tools will undoubtedly make the crewmembers task easier, but they can also add to overall task complexity if not properly designed. A leading candidate technology for supporting a hands-free environment is the Head-Mounted Display (HMD). A more recent technology (e-book reader) that could be easily temp-stowed near the work area is also a potential hands-free solution. Previous work at NASA involved the evaluation of several commercially available HMDs for visual quality, comfort, and fit, as well as suitability for use in microgravity. Based on results from this work, three HMDs were selected for further evaluation (along with an e-book reader), using International Space Station (ISS)-like maintenance procedures. Two evaluations were conducted in the Space Station Mockup and Trainer Facility (SSMTF) located at the NASA Johnson Space Center (building 9). The SSMTF is a full scale, medium fidelity replica of the pressurized portions of the ISS. It supports crew training such as ingress and egress, habitability, and emergency procedures. In each of the two evaluations, the participants performed two maintenance procedures. One maintenance procedure involved inspecting air filters in a life support system and replacing them with a clean filter if one were found to be contaminated. The second

  8. Intelligent, self-contained robotic hand

    Science.gov (United States)

    Krutik, Vitaliy; Doo, Burt; Townsend, William T.; Hauptman, Traveler; Crowell, Adam; Zenowich, Brian; Lawson, John

    2007-01-30

    A robotic device has a base and at least one finger having at least two links that are connected in series on rotary joints with at least two degrees of freedom. A brushless motor and an associated controller are located at each joint to produce a rotational movement of a link. Wires for electrical power and communication serially connect the controllers in a distributed control network. A network operating controller coordinates the operation of the network, including power distribution. At least one, but more typically two to five, wires interconnect all the controllers through one or more joints. Motor sensors and external world sensors monitor operating parameters of the robotic hand. The electrical signal output of the sensors can be input anywhere on the distributed control network. V-grooves on the robotic hand locate objects precisely and assist in gripping. The hand is sealed, immersible and has electrical connections through the rotary joints for anodizing in a single dunk without masking. In various forms, this intelligent, self-contained, dexterous hand, or combinations of such hands, can perform a wide variety of object gripping and manipulating tasks, as well as locomotion and combinations of locomotion and gripping.

  9. Natural control capabilities of robotic hands by hand amputated subjects.

    Science.gov (United States)

    Atzori, Manfredo; Gijsberts, Arjan; Caputo, Barbara; Muller, Henning

    2014-01-01

    People with transradial hand amputations who own a myoelectric prosthesis currently have some control capabilities via sEMG. However, the control systems are still limited and not natural. The Ninapro project is aiming at helping the scientific community to overcome these limits through the creation of publicly available electromyography data sources to develop and test machine learning algorithms. In this paper we describe the movement classification results gained from three subjects with an homogeneous level of amputation, and we compare them with the results of 40 intact subjects. The number of considered subjects can seem small at first sight, but it is not considering the literature of the field (which has to face the difficulty of recruiting trans-radial hand amputated subjects). The classification is performed with four different classifiers and the obtained balanced classification rates are up to 58.6% on 50 movements, which is an excellent result compared to the current literature. Successively, for each subject we find a subset of up to 9 highly independent movements, (defined as movements that can be distinguished with more than 90% accuracy), which is a deeply innovative step in literature. The natural control of a robotic hand in so many movements could lead to an immediate progress in robotic hand prosthetics and it could deeply change the quality of life of amputated subjects.

  10. Development of Advanced Robotic Hand System for space application

    Science.gov (United States)

    Machida, Kazuo; Akita, Kenzo; Mikami, Tatsuo; Komada, Satoru

    1994-01-01

    The Advanced Robotic Hand System (ARH) is a precise telerobotics system with a semi dexterous hand for future space application. The ARH will be tested in space as one of the missions of the Engineering Tests Satellite 7 (ETS-7) which will be launched in 1997. The objectives of the ARH development are to evaluate the capability of a possible robot hand for precise and delicate tasks and to validate the related technologies implemented in the system. The ARH is designed to be controlled both from ground as a teleoperation and by locally autonomous control. This paper presents the overall system design and the functional capabilities of the ARH as well as its mission outline as the preliminary design has been completed.

  11. A hand-held 3D laser scanning with global positioning system of subvoxel precision

    International Nuclear Information System (INIS)

    Arias, Nestor; Meneses, Nestor; Meneses, Jaime; Gharbi, Tijani

    2011-01-01

    In this paper we propose a hand-held 3D laser scanner composed of an optical head device to extract 3D local surface information and a stereo vision system with subvoxel precision to measure the position and orientation of the 3D optical head. The optical head is manually scanned over the surface object by the operator. The orientation and position of the 3D optical head is determined by a phase-sensitive method using a 2D regular intensity pattern. This phase reference pattern is rigidly fixed to the optical head and allows their 3D location with subvoxel precision in the observation field of the stereo vision system. The 3D resolution achieved by the stereo vision system is about 33 microns at 1.8 m with an observation field of 60cm x 60cm.

  12. Intelligent computational control of multi-fingered dexterous robotic hand

    OpenAIRE

    Chen, Disi; Li, Gongfa; Jiang, Guozhang; Fang, Yinfeng; Ju, Zhaojie; Liu, Honghai

    2015-01-01

    We discuss the intelligent computational control theory and introduce the hardware structure of HIT/DLR II dexterous robotic hand, which is the typical dexterous robotic hand. We show that how DSP or FPGA controller can be used in the dexterous robotic hand. A popular intelligent dexterous robotic hand control system, which named Electromyography (EMG) control is investigated. We introduced some mathematical algorithms in EMG controlling, such as Gauss mixture model (GMM), artificial neural n...

  13. A systematic review of the effectiveness of antimicrobial rinse-free hand sanitizers for prevention of illness-related absenteeism in elementary school children

    OpenAIRE

    Meadows, Emily; Le Saux, Nicole

    2004-01-01

    Abstract Background Absenteeism due to communicable illness is a major problem encountered by North American elementary school children. Although handwashing is a proven infection control measure, barriers exist in the school environment, which hinder compliance to this routine. Currently, alternative hand hygiene techniques are being considered, and one such technique is the use of antimicrobial rinse-free hand sanitizers. Methods A systematic review was conducted to examine the effectivenes...

  14. Web-based interactive drone control using hand gesture

    Science.gov (United States)

    Zhao, Zhenfei; Luo, Hao; Song, Guang-Hua; Chen, Zhou; Lu, Zhe-Ming; Wu, Xiaofeng

    2018-01-01

    This paper develops a drone control prototype based on web technology with the aid of hand gesture. The uplink control command and downlink data (e.g., video) are transmitted by WiFi communication, and all the information exchange is realized on web. The control command is translated from various predetermined hand gestures. Specifically, the hardware of this friendly interactive control system is composed by a quadrotor drone, a computer vision-based hand gesture sensor, and a cost-effective computer. The software is simplified as a web-based user interface program. Aided by natural hand gestures, this system significantly reduces the complexity of traditional human-computer interaction, making remote drone operation more intuitive. Meanwhile, a web-based automatic control mode is provided in addition to the hand gesture control mode. For both operation modes, no extra application program is needed to be installed on the computer. Experimental results demonstrate the effectiveness and efficiency of the proposed system, including control accuracy, operation latency, etc. This system can be used in many applications such as controlling a drone in global positioning system denied environment or by handlers without professional drone control knowledge since it is easy to get started.

  15. Web-based interactive drone control using hand gesture.

    Science.gov (United States)

    Zhao, Zhenfei; Luo, Hao; Song, Guang-Hua; Chen, Zhou; Lu, Zhe-Ming; Wu, Xiaofeng

    2018-01-01

    This paper develops a drone control prototype based on web technology with the aid of hand gesture. The uplink control command and downlink data (e.g., video) are transmitted by WiFi communication, and all the information exchange is realized on web. The control command is translated from various predetermined hand gestures. Specifically, the hardware of this friendly interactive control system is composed by a quadrotor drone, a computer vision-based hand gesture sensor, and a cost-effective computer. The software is simplified as a web-based user interface program. Aided by natural hand gestures, this system significantly reduces the complexity of traditional human-computer interaction, making remote drone operation more intuitive. Meanwhile, a web-based automatic control mode is provided in addition to the hand gesture control mode. For both operation modes, no extra application program is needed to be installed on the computer. Experimental results demonstrate the effectiveness and efficiency of the proposed system, including control accuracy, operation latency, etc. This system can be used in many applications such as controlling a drone in global positioning system denied environment or by handlers without professional drone control knowledge since it is easy to get started.

  16. Numerical precision control and GRACE

    International Nuclear Information System (INIS)

    Fujimoto, J.; Hamaguchi, N.; Ishikawa, T.; Kaneko, T.; Morita, H.; Perret-Gallix, D.; Tokura, A.; Shimizu, Y.

    2006-01-01

    The control of the numerical precision of large-scale computations like those generated by the GRACE system for automatic Feynman diagram calculations has become an intrinsic part of those packages. Recently, Hitachi Ltd. has developed in FORTRAN a new library HMLIB for quadruple and octuple precision arithmetic where the number of lost-bits is made available. This library has been tested with success on the 1-loop radiative correction to e + e - ->e + e - τ + τ - . It is shown that the approach followed by HMLIB provides an efficient way to track down the source of numerical significance losses and to deliver high-precision results yet minimizing computing time

  17. Earable TEMPO: A Novel, Hands-Free Input Device that Uses the Movement of the Tongue Measured with a Wearable Ear Sensor

    Directory of Open Access Journals (Sweden)

    Kazuhiro Taniguchi

    2018-03-01

    Full Text Available In this study, an earphone-type interface named “earable TEMPO” was developed for hands-free operation, wherein the user can control the device by simply pushing the tongue against the roof of the mouth for about one second. This interface can be used to start and stop the music from a portable audio player. The earable TEMPO uses an earphone-type sensor equipped with a light emitting diode (LED and a phototransistor to optically measure shape variations that occur in the external auditory meatus when the tongue is pressed against the roof of the mouth. To evaluate the operation of the earable TEMPO, experiments were performed on five subjects (men and women aged 22–58 while resting, chewing gum (representing mastication, and walking. The average accuracy was 100% while resting and chewing and 99% while walking. The precision was 100% under all conditions. The average recall value of the five subjects was 92%, 90%, and 48% while resting, masticating, and walking, respectively. All subjects were reliably able to perform the action of pressing the tongue against the roof of the mouth. The measured shape variations in the ear canal were highly reproducible, indicating that this method is suitable for various applications such as controlling a portable audio player.

  18. Precise gouging-free tool orientations for 5-axis CNC machining

    KAUST Repository

    Kim, Yong-Joon

    2014-08-19

    We present a precise approach to the generation of optimized collision-free and gouging-free tool paths for 5-axis CNC machining of freeform NURBS surfaces using flat-end and rounded-end (bull nose) tools having cylindrical shank. To achieve high approximation quality, we employ analysis of hyper-osculating circles (HOCs) (Wang et al., 1993a,b), that have third order contact with the target surface, and lead to a locally collision-free configuration between the tool and the target surface. At locations where an HOC is not possible, we aim at a double tangential contact among the tool and the target surface, and use it as a bridge between the feasible HOC tool paths. We formulate all such possible two-contact configurations as systems of algebraic constraints and solve them. For all feasible HOCs and two-contact configurations, we perform a global optimization to find the tool path that maximizes the approximation quality of the machining, while being gouge-free and possibly satisfying constraints on the tool tilt and the tool acceleration. We demonstrate the effectiveness of our approach via several experimental results.

  19. Precise gouging-free tool orientations for 5-axis CNC machining

    KAUST Repository

    Kim, Yong-Joon; Elber, Gershon; Barton, Michael; Pottmann, Helmut

    2014-01-01

    We present a precise approach to the generation of optimized collision-free and gouging-free tool paths for 5-axis CNC machining of freeform NURBS surfaces using flat-end and rounded-end (bull nose) tools having cylindrical shank. To achieve high approximation quality, we employ analysis of hyper-osculating circles (HOCs) (Wang et al., 1993a,b), that have third order contact with the target surface, and lead to a locally collision-free configuration between the tool and the target surface. At locations where an HOC is not possible, we aim at a double tangential contact among the tool and the target surface, and use it as a bridge between the feasible HOC tool paths. We formulate all such possible two-contact configurations as systems of algebraic constraints and solve them. For all feasible HOCs and two-contact configurations, we perform a global optimization to find the tool path that maximizes the approximation quality of the machining, while being gouge-free and possibly satisfying constraints on the tool tilt and the tool acceleration. We demonstrate the effectiveness of our approach via several experimental results.

  20. The accuracy, precision and sustainability of different techniques for tablet subdivision: breaking by hand and the use of tablet splitters or a kitchen knife.

    Science.gov (United States)

    van Riet-Nales, Diana A; Doeve, Myrthe E; Nicia, Agnes E; Teerenstra, Steven; Notenboom, Kim; Hekster, Yechiel A; van den Bemt, Bart J F

    2014-05-15

    Tablets are frequently subdivided to lower the dose, to facilitate swallowing by e.g. children or older people or to save costs. Splitting devices are commonly used when hand breaking is difficult or painful. Three techniques for tablet subdivision were investigated: hand breaking, tablet splitter, kitchen knife. A best case drug (paracetamol), tablet (round, flat, uncoated, 500 mg) and operator (24-year student) were applied. Hundred tablets were subdivided by hand and by three devices of each of the following types: Fit & Healthy, Health Care Logistics, Lifetime, PillAid, PillTool, Pilomat tablet splitter; Blokker kitchen knife. The intra and inter device accuracy, precision and sustainability were investigated. The compliance to (adapted) regulatory requirements was investigated also. The accuracy and precision of hand broken tablets was 104/97% resp. 2.8/3.2% (one part per tablet considered; parts right/left side operator). The right/left accuracies of the splitting devices varied between 60 and 133%; the precisions 4.0 and 29.6%. The devices did not deteriorate over 100-fold use. Only hand broken tablets complied with all regulatory requirements. Health care professionals should realize that tablet splitting may result in inaccurate dosing. Authorities should undertake appropriate measures to assure good function of tablet splitters and, where feasible, to reduce the need for their use. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  1. Controller design for Robotic hand through Electroencephalogram

    OpenAIRE

    Pandelidis P.; Kiriazis N.; Orgianelis K.; Koulios N.

    2016-01-01

    - This paper deals with the designing, the construction and the control of a robotic hand via an electroencephalogram sensor. First a robotic device that is able to mimic a real human hand is constructed. A PID controller is designed in order to improve the performance of the robotic arm for grabbing objects. Furthermore, a novel design approach is presented for controlling the motion of the robotic arm using signals produced from an innovative electroencephalogram sensor that detects the con...

  2. Control System Design of the YWZ Multi-Fingered Dexterous Hand

    Directory of Open Access Journals (Sweden)

    Wenzhen Yang

    2012-07-01

    Full Text Available The manipulation abilities of a multi-fingered dexterous hand, such as motion in real-time, flexibility, grasp stability etc., are largely dependent on its control system. This paper developed a control system for the YWZ dexterous hand, which had five fingers and twenty degrees of freedom (DOFs. All of the finger joints of the YWZ dexterous handwere active joints driven by twenty micro-stepper motors respectively. The main contribution of this paper was that we were able to use stepper motor control to actuate the hand's fingers, thus, increasing the hands feasibility. Based the actuators of the YWZ dexterous hand, we firstly developed an integrated circuit board (ICB, which was the communication hardware between the personal computer (PC and the YWZ dexterous hand. The ICB included a centre controller, twenty driver chips, a USB port and other electrical parts. Then, a communication procedure between the PC and the ICB was developed to send the control commands to actuate the YWZ dexterous hand. Experiment results showed that under this control system, the motion of the YWZ dexterous hand was real-time; both the motion accuracy and the motion stability of the YWZ dexterous hand were reliable. Compared with other types of actuators related to dexterous hands, such as pneumatic servo cylinder, DC servo motor, shape memory alloy etc., experiment results verified that the stepper motors as actuators for the dexterous handswere effective, economical, controllable and stable.

  3. Controller design for Robotic hand through Electroencephalogram

    Directory of Open Access Journals (Sweden)

    Pandelidis P.

    2016-01-01

    Full Text Available - This paper deals with the designing, the construction and the control of a robotic hand via an electroencephalogram sensor. First a robotic device that is able to mimic a real human hand is constructed. A PID controller is designed in order to improve the performance of the robotic arm for grabbing objects. Furthermore, a novel design approach is presented for controlling the motion of the robotic arm using signals produced from an innovative electroencephalogram sensor that detects the concentration of the brain

  4. Research on direct calibration method of eye-to-hand system of robot

    Science.gov (United States)

    Hu, Xiaoping; Xie, Ke; Peng, Tao

    2013-10-01

    In the position-based visual servoing control for robot, the hand-eye calibration is very important because it can affect the control precision of the system. According to the robot with eye-to-hand stereovision system, this paper proposes a direct method of hand-eye calibration. The method utilizes the triangle measuring principle to solve the coordinates in the camera coordinate system of scene point. It calculates the estimated coordinates by the hand-eye calibration equation set which indicates the transformational relation from the robot to the camera coordinate system, and then uses the error of actual and estimated coordinates to establish the objective function. Finally the method substitutes the parameters into the function repeatedly until it converged to optimize the result. The related experiment compared the measured coordinates with the actual coordinates, shows the efficiency and the precision of it.

  5. [Infection control and hand hygiene in nursing homes in Oslo].

    Science.gov (United States)

    Sie, Ingrid; Thorstad, Margrete; Andersen, Bjørg Marit

    2008-06-26

    Nosocomial infections and transmission can be substantially reduced by good infection control. The laws and regulations for infection control in heath care institutions emphasize establishment of infection control programs and improved hand hygiene. Our study reviews some factors that are important for practicing adequate hand hygiene (knowledge about infection control and hand-washing facilities). Health care workers (HCW) in nursing homes in Oslo participated in this study in 2006-2007. A questionnaire was made and SPSS was used to analyse the data . 70.7% of 324 HCW (in 42 nursing homes) answered the questionnaires. Nearly all of the respondents (95.6%) knew about the written procedures for hygiene and infection control; 88.5% knew that an infection control program was in place and about 50% had received information through internal education. Three of four had read the National guidelines for hand hygiene, 77.5% thought that hand disinfection was more effective than hand washing, and 97% reported hand hygiene after contact with a patient having an infection. Dispensers for hand disinfection were situated at central work places. At the same time, 17.9% informed that they worked in more than one place at the same time. This study confirms that most nursing homes in Oslo have an infection control program and training that improves the knowledge and awareness of hand hygiene among HCWs. However, the fact that nursing homes in Oslo have the resources, knowledge and education, is not the same as compliance.

  6. Radial forearm free flap morbidity: A rare case of a normal preoperative arteriogram and acute intraoperative hand ischemia

    OpenAIRE

    Bruner, Terrence W; Hanasono, Matthew M; Skoracki, Roman J

    2011-01-01

    The radial forearm free flap is ideal for reconstructive microsurgery due to its thin, pliable fasciocutaneous tissue, reliable anatomy and ease and simplicity of flap elevation. However, one of the major complications is hand ischemia due to sacrifice of the radial artery, although it is a rare occurrence. A case involving a 73-year-old man who developed intraoperative hand ischemia after elevation of a radial forearm free flap is presented.

  7. Hand Hygiene, Cohorting, or Antibiotic Restriction to Control Outbreaks of Multidrug-Resistant Enterobacteriaceae.

    Science.gov (United States)

    Pelat, Camille; Kardaś-Słoma, Lidia; Birgand, Gabriel; Ruppé, Etienne; Schwarzinger, Michaël; Andremont, Antoine; Lucet, Jean-Christophe; Yazdanpanah, Yazdan

    2016-03-01

    The best strategy for controlling extended-spectrum β-lactamase-producing Enterobacteriaceae (ESBL-PE) transmission in intensive care units (ICUs) remains elusive. We developed a stochastic transmission model to quantify the effectiveness of interventions aimed at reducing the spread of ESBL-PE in an ICU. We modeled the evolution of an outbreak caused by the admission of a single carrier in a 10-bed ICU free of ESBL-PE. Using data obtained from recent muticenter studies, we studied 26 strategies combining different levels of the following 3 interventions: (1) increasing healthcare worker compliance with hand hygiene before and after contact with a patient; (2) cohorting; (3) reducing antibiotic prevalence at admission with or without reducing antibiotherapy duration. Improving hand hygiene compliance from 55% before patient contact and 60% after patient contact to 80% before and 80% after patient contact reduced the nosocomial incidence rate of ESBL-PE colonization by 91% at 90 days. Adding cohorting to hand hygiene improvement intervention decreased the proportion of ESBL-PE acquisitions by an additional 7%. Antibiotic restriction had the lowest impact on the epidemic. When combined with other interventions, it only marginally improved effectiveness, despite strong hypotheses regarding antibiotic impact on transmission. Our results suggest that hand hygiene is the most effective intervention to control ESBL-PE transmission in an ICU.

  8. Electromyography data for non-invasive naturally-controlled robotic hand prostheses.

    Science.gov (United States)

    Atzori, Manfredo; Gijsberts, Arjan; Castellini, Claudio; Caputo, Barbara; Hager, Anne-Gabrielle Mittaz; Elsig, Simone; Giatsidis, Giorgio; Bassetto, Franco; Müller, Henning

    2014-01-01

    Recent advances in rehabilitation robotics suggest that it may be possible for hand-amputated subjects to recover at least a significant part of the lost hand functionality. The control of robotic prosthetic hands using non-invasive techniques is still a challenge in real life: myoelectric prostheses give limited control capabilities, the control is often unnatural and must be learned through long training times. Meanwhile, scientific literature results are promising but they are still far from fulfilling real-life needs. This work aims to close this gap by allowing worldwide research groups to develop and test movement recognition and force control algorithms on a benchmark scientific database. The database is targeted at studying the relationship between surface electromyography, hand kinematics and hand forces, with the final goal of developing non-invasive, naturally controlled, robotic hand prostheses. The validation section verifies that the data are similar to data acquired in real-life conditions, and that recognition of different hand tasks by applying state-of-the-art signal features and machine-learning algorithms is possible.

  9. Sensing human hand motions for controlling dexterous robots

    Science.gov (United States)

    Marcus, Beth A.; Churchill, Philip J.; Little, Arthur D.

    1988-01-01

    The Dexterous Hand Master (DHM) system is designed to control dexterous robot hands such as the UTAH/MIT and Stanford/JPL hands. It is the first commercially available device which makes it possible to accurately and confortably track the complex motion of the human finger joints. The DHM is adaptable to a wide variety of human hand sizes and shapes, throughout their full range of motion.

  10. A Retrospective Analysis of Precision Medicine Outcomes in Patients With Advanced Cancer Reveals Improved Progression-Free Survival Without Increased Health Care Costs.

    Science.gov (United States)

    Haslem, Derrick S; Van Norman, S Burke; Fulde, Gail; Knighton, Andrew J; Belnap, Tom; Butler, Allison M; Rhagunath, Sharanya; Newman, David; Gilbert, Heather; Tudor, Brian P; Lin, Karen; Stone, Gary R; Loughmiller, David L; Mishra, Pravin J; Srivastava, Rajendu; Ford, James M; Nadauld, Lincoln D

    2017-02-01

    The advent of genomic diagnostic technologies such as next-generation sequencing has recently enabled the use of genomic information to guide targeted treatment in patients with cancer, an approach known as precision medicine. However, clinical outcomes, including survival and the cost of health care associated with precision cancer medicine, have been challenging to measure and remain largely unreported. We conducted a matched cohort study of 72 patients with metastatic cancer of diverse subtypes in the setting of a large, integrated health care delivery system. We analyzed the outcomes of 36 patients who received genomic testing and targeted therapy (precision cancer medicine) between July 1, 2013, and January 31, 2015, compared with 36 historical control patients who received standard chemotherapy (n = 29) or best supportive care (n = 7). The average progression-free survival was 22.9 weeks for the precision medicine group and 12.0 weeks for the control group ( P = .002) with a hazard ratio of 0.47 (95% CI, 0.29 to 0.75) when matching on age, sex, histologic diagnosis, and previous lines of treatment. In a subset analysis of patients who received all care within the Intermountain Healthcare system (n = 44), per patient charges per week were $4,665 in the precision treatment group and $5,000 in the control group ( P = .126). These findings suggest that precision cancer medicine may improve survival for patients with refractory cancer without increasing health care costs. Although the results of this study warrant further validation, this precision medicine approach may be a viable option for patients with advanced cancer.

  11. Hand Preference for Precision Grasping Predicts Language Lateralization

    Science.gov (United States)

    Gonzalez, Claudia L. R.; Goodale, Melvyn A.

    2009-01-01

    We investigated whether or not there is a relationship between hand preference for grasping and hemispheric dominance for language--and how each of these is related to other traditional measures of handedness. To do this we asked right- and left-handed participants to put together two different sets of 3D puzzles made out of big or very small…

  12. Patterning a hydrogen-bonded molecular monolayer with a hand-controlled scanning probe microscope

    Directory of Open Access Journals (Sweden)

    Matthew F. B. Green

    2014-10-01

    Full Text Available One of the paramount goals in nanotechnology is molecular-scale functional design, which includes arranging molecules into complex structures at will. The first steps towards this goal were made through the invention of the scanning probe microscope (SPM, which put single-atom and single-molecule manipulation into practice for the first time. Extending the controlled manipulation to larger molecules is expected to multiply the potential of engineered nanostructures. Here we report an enhancement of the SPM technique that makes the manipulation of large molecular adsorbates much more effective. By using a commercial motion tracking system, we couple the movements of an operator's hand to the sub-angstrom precise positioning of an SPM tip. Literally moving the tip by hand we write a nanoscale structure in a monolayer of large molecules, thereby showing that our method allows for the successful execution of complex manipulation protocols even when the potential energy surface that governs the interaction behaviour of the manipulated nanoscale object(s is largely unknown.

  13. Design of a 3-DOF Parallel Hand-Controller

    Directory of Open Access Journals (Sweden)

    Chengcheng Zhu

    2017-01-01

    Full Text Available Hand-controllers, as human-machine-interface (HMI devices, can transfer the position information of the operator’s hands into the virtual environment to control the target objects or a real robot directly. At the same time, the haptic information from the virtual environment or the sensors on the real robot can be displayed to the operator. It helps human perceive haptic information more truly with feedback force. A parallel hand-controller is designed in this paper. It is simplified from the traditional delta haptic device. The swing arms in conventional delta devices are replaced with the slider rail modules. The base consists of two hexagons and several links. For the use of the linear sliding modules instead of swing arms, the arc movement is replaced by linear movement. So that, the calculating amount of the position positive solution and the force inverse solution is reduced for the simplification of the motion. The kinematics, static mechanics, and dynamic mechanics are analyzed in this paper. What is more, two demonstration applications are developed to verify the performance of the designed hand-controller.

  14. Integrated multi-sensory control of space robot hand

    Science.gov (United States)

    Bejczy, A. K.; Kan, E. P.; Killion, R. R.

    1985-01-01

    Dexterous manipulation of a robot hand requires the use of multiple sensors integrated into the mechanical hand under distributed microcomputer control. Where space applications such as construction, assembly, servicing and repair tasks are desired of smart robot arms and robot hands, several critical drives influence the design, engineering and integration of such an electromechanical hand. This paper describes a smart robot hand developed at the Jet Propulsion Laboratory for experimental use and evaluation with the Protoflight Manipulator Arm (PFMA) at the Marshall Space Flight Center (MSFC).

  15. Neural-Network Control Of Prosthetic And Robotic Hands

    Science.gov (United States)

    Buckley, Theresa M.

    1991-01-01

    Electronic neural networks proposed for use in controlling robotic and prosthetic hands and exoskeletal or glovelike electromechanical devices aiding intact but nonfunctional hands. Specific to patient, who activates grasping motion by voice command, by mechanical switch, or by myoelectric impulse. Patient retains higher-level control, while lower-level control provided by neural network analogous to that of miniature brain. During training, patient teaches miniature brain to perform specialized, anthropomorphic movements unique to himself or herself.

  16. The efficacy of different models of smoke-free laws in reducing exposure to second-hand smoke: a multi-country comparison.

    Science.gov (United States)

    Ward, Mark; Currie, Laura M; Kabir, Zubair; Clancy, Luke

    2013-05-01

    Exposure to second-hand tobacco smoke is a serious public health concern and while all EU Member States have enacted some form of regulation aimed at limiting exposure, the scope of these regulations vary widely and many countries have failed to enact comprehensive legislation creating smoke-free workplaces and indoor public places. To gauge the effectiveness of different smoke-free models we compared fine particles from second-hand smoke in hospitality venues before and after the implementation of smoking bans in France, Greece, Ireland, Italy, Portugal, Turkey, and Scotland. Data on PM2.5 fine particle concentration levels were recorded in 338 hospitality venues across these countries before and after the implementation of smoke-free legislation. Changes in mean PM2.5 concentrations during the period from pre- to post-legislation were then compared across countries. While a reduction in PM2.5 was observed in all countries, those who had enacted and enforced more fully comprehensive smoke-free legislation experienced the greatest reduction in second-hand tobacco smoke. Comprehensive smoke-free laws are more effective than partial laws in reducing exposure to second-hand tobacco smoke. Also, any law, regardless of scope must be actively enforced in order to have the desired impact. There is continued need for surveillance of smoke-free efforts in all countries. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. Flexible integration of free-standing nanowires into silicon photonics.

    Science.gov (United States)

    Chen, Bigeng; Wu, Hao; Xin, Chenguang; Dai, Daoxin; Tong, Limin

    2017-06-14

    Silicon photonics has been developed successfully with a top-down fabrication technique to enable large-scale photonic integrated circuits with high reproducibility, but is limited intrinsically by the material capability for active or nonlinear applications. On the other hand, free-standing nanowires synthesized via a bottom-up growth present great material diversity and structural uniformity, but precisely assembling free-standing nanowires for on-demand photonic functionality remains a great challenge. Here we report hybrid integration of free-standing nanowires into silicon photonics with high flexibility by coupling free-standing nanowires onto target silicon waveguides that are simultaneously used for precise positioning. Coupling efficiency between a free-standing nanowire and a silicon waveguide is up to ~97% in the telecommunication band. A hybrid nonlinear-free-standing nanowires-silicon waveguides Mach-Zehnder interferometer and a racetrack resonator for significantly enhanced optical modulation are experimentally demonstrated, as well as hybrid active-free-standing nanowires-silicon waveguides circuits for light generation. These results suggest an alternative approach to flexible multifunctional on-chip nanophotonic devices.Precisely assembling free-standing nanowires for on-demand photonic functionality remains a challenge. Here, Chen et al. integrate free-standing nanowires into silicon waveguides and show all-optical modulation and light generation on silicon photonic chips.

  18. Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands

    Science.gov (United States)

    Santello, Marco; Bianchi, Matteo; Gabiccini, Marco; Ricciardi, Emiliano; Salvietti, Gionata; Prattichizzo, Domenico; Ernst, Marc; Moscatelli, Alessandro; Jörntell, Henrik; Kappers, Astrid M. L.; Kyriakopoulos, Kostas; Albu-Schäffer, Alin; Castellini, Claudio; Bicchi, Antonio

    2016-07-01

    The term 'synergy' - from the Greek synergia - means 'working together'. The concept of multiple elements working together towards a common goal has been extensively used in neuroscience to develop theoretical frameworks, experimental approaches, and analytical techniques to understand neural control of movement, and for applications for neuro-rehabilitation. In the past decade, roboticists have successfully applied the framework of synergies to create novel design and control concepts for artificial hands, i.e., robotic hands and prostheses. At the same time, robotic research on the sensorimotor integration underlying the control and sensing of artificial hands has inspired new research approaches in neuroscience, and has provided useful instruments for novel experiments. The ambitious goal of integrating expertise and research approaches in robotics and neuroscience to study the properties and applications of the concept of synergies is generating a number of multidisciplinary cooperative projects, among which the recently finished 4-year European project ;The Hand Embodied; (THE). This paper reviews the main insights provided by this framework. Specifically, we provide an overview of neuroscientific bases of hand synergies and introduce how robotics has leveraged the insights from neuroscience for innovative design in hardware and controllers for biomedical engineering applications, including myoelectric hand prostheses, devices for haptics research, and wearable sensing of human hand kinematics. The review also emphasizes how this multidisciplinary collaboration has generated new ways to conceptualize a synergy-based approach for robotics, and provides guidelines and principles for analyzing human behavior and synthesizing artificial robotic systems based on a theory of synergies.

  19. Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands

    Science.gov (United States)

    Santello, Marco; Bianchi, Matteo; Gabiccini, Marco; Ricciardi, Emiliano; Salvietti, Gionata; Prattichizzo, Domenico; Ernst, Marc; Moscatelli, Alessandro; Jörntell, Henrik; Kappers, Astrid M.L.; Kyriakopoulos, Kostas; Albu-Schäffer, Alin; Castellini, Claudio; Bicchi, Antonio

    2017-01-01

    The term ‘synergy’ – from the Greek synergia – means ‘working together’. The concept of multiple elements working together towards a common goal has been extensively used in neuroscience to develop theoretical frameworks, experimental approaches, and analytical techniques to understand neural control of movement, and for applications for neuro-rehabilitation. In the past decade, roboticists have successfully applied the framework of synergies to create novel design and control concepts for artificial hands, i.e., robotic hands and prostheses. At the same time, robotic research on the sensorimotor integration underlying the control and sensing of artificial hands has inspired new research approaches in neuroscience, and has provided useful instruments for novel experiments. The ambitious goal of integrating expertise and research approaches in robotics and neuroscience to study the properties and applications of the concept of synergies is generating a number of multidisciplinary cooperative projects, among which the recently finished 4-year European project “The Hand Embodied” (THE). This paper reviews the main insights provided by this framework. Specifically, we provide an overview of neuroscientific bases of hand synergies and introduce how robotics has leveraged the insights from neuroscience for innovative design in hardware and controllers for biomedical engineering applications, including myoelectric hand prostheses, devices for haptics research, and wearable sensing of human hand kinematics. The review also emphasizes how this multidisciplinary collaboration has generated new ways to conceptualize a synergy-based approach for robotics, and provides guidelines and principles for analyzing human behavior and synthesizing artificial robotic systems based on a theory of synergies. PMID:26923030

  20. Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands.

    Science.gov (United States)

    Santello, Marco; Bianchi, Matteo; Gabiccini, Marco; Ricciardi, Emiliano; Salvietti, Gionata; Prattichizzo, Domenico; Ernst, Marc; Moscatelli, Alessandro; Jörntell, Henrik; Kappers, Astrid M L; Kyriakopoulos, Kostas; Albu-Schäffer, Alin; Castellini, Claudio; Bicchi, Antonio

    2016-07-01

    The term 'synergy' - from the Greek synergia - means 'working together'. The concept of multiple elements working together towards a common goal has been extensively used in neuroscience to develop theoretical frameworks, experimental approaches, and analytical techniques to understand neural control of movement, and for applications for neuro-rehabilitation. In the past decade, roboticists have successfully applied the framework of synergies to create novel design and control concepts for artificial hands, i.e., robotic hands and prostheses. At the same time, robotic research on the sensorimotor integration underlying the control and sensing of artificial hands has inspired new research approaches in neuroscience, and has provided useful instruments for novel experiments. The ambitious goal of integrating expertise and research approaches in robotics and neuroscience to study the properties and applications of the concept of synergies is generating a number of multidisciplinary cooperative projects, among which the recently finished 4-year European project "The Hand Embodied" (THE). This paper reviews the main insights provided by this framework. Specifically, we provide an overview of neuroscientific bases of hand synergies and introduce how robotics has leveraged the insights from neuroscience for innovative design in hardware and controllers for biomedical engineering applications, including myoelectric hand prostheses, devices for haptics research, and wearable sensing of human hand kinematics. The review also emphasizes how this multidisciplinary collaboration has generated new ways to conceptualize a synergy-based approach for robotics, and provides guidelines and principles for analyzing human behavior and synthesizing artificial robotic systems based on a theory of synergies. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Release of hand burn contracture: comparing the ALT perforator flap with the gracilis free flap with split skin graft.

    Science.gov (United States)

    Misani, M; Zirak, C; Hau, Lê Thua Trung; De Mey, A; Boeckx, W

    2013-08-01

    The use of microsurgery in the management of burn sequelae is not a new idea. According to the properties of various types of free flaps different goals can be achieved or various additional procedures have to be combined. We report the comparison of two different free flaps on a single patient for reconstruction of both upper extremities for burn sequelae. A 1-year-old child sustained severe burns on both hands, arms and thorax and was initially only treated conservatively. This resulted in severe contractures. At the age of 4-years a free gracilis flap was selected for reconstruction of his left hand and a free anterolateral thigh flap for the right hand. We noticed a better functional and esthetic result for the gracilis flap associated with a shorter operative time and a minor donor site morbidity. The intraoperative technique and time, postoperative complications, functional and esthetic results and donor site morbidities were studied in the two types of flaps chosen. A review of literature was also performed. Our experience reported a better success of the gracilis muscle flap covered with a split skin graft compared to the anterolateral thigh flap in the reconstruction of hand function after severe burn sequelae. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.

  2. 49 CFR 236.207 - Electric lock on hand-operated switch; control.

    Science.gov (United States)

    2010-10-01

    ..., AND APPLIANCES Automatic Block Signal Systems Standards § 236.207 Electric lock on hand-operated switch; control. Electric lock on hand-operated switch shall be controlled so that it cannot be unlocked... 49 Transportation 4 2010-10-01 2010-10-01 false Electric lock on hand-operated switch; control...

  3. Novel Approach to Control of Robotic Hand Using Flex Sensors

    Directory of Open Access Journals (Sweden)

    Sandesh R.S

    2014-05-01

    Full Text Available This paper discuss about novel design approach to control of a robotic hand using flex sensors which indicates a biomechatronic multi fingered robotic hand. This robotic hand consists of base unit, upper arm, lower arm, palm and five fingers. The aim is to develop an anthropomorphic five fingered robotic hand. The proposed design illustrates the use of 5 micro DC motors with 9 Degrees of Freedom (DOF.Each finger is controlled independently. Further three extra motors were used for the control of wrist elbow and base movement. The study of the DC motor is being carried out using the transfer function model for constant excitation. The micro DC motor performance was analyzed using MATLAB simulation environment. The whole system is implemented using flex sensors. The flex sensors placed on the human hand gloves appear as if they look like real human hand.  89v51 microcontroller was used for all the controlling actions along with RF transmitter/receiver .The performance of the system has been conducted experimentally and studied.

  4. Optimizing pattern recognition-based control for partial-hand prosthesis application.

    Science.gov (United States)

    Earley, Eric J; Adewuyi, Adenike A; Hargrove, Levi J

    2014-01-01

    Partial-hand amputees often retain good residual wrist motion, which is essential for functional activities involving use of the hand. Thus, a crucial design criterion for a myoelectric, partial-hand prosthesis control scheme is that it allows the user to retain residual wrist motion. Pattern recognition (PR) of electromyographic (EMG) signals is a well-studied method of controlling myoelectric prostheses. However, wrist motion degrades a PR system's ability to correctly predict hand-grasp patterns. We studied the effects of (1) window length and number of hand-grasps, (2) static and dynamic wrist motion, and (3) EMG muscle source on the ability of a PR-based control scheme to classify functional hand-grasp patterns. Our results show that training PR classifiers with both extrinsic and intrinsic muscle EMG yields a lower error rate than training with either group by itself (pgrasps available to the classifier significantly decrease classification error (pgrasp.

  5. Myoelectric control of prosthetic hands: state-of-the-art review

    Directory of Open Access Journals (Sweden)

    Geethanjali P

    2016-07-01

    Full Text Available Purushothaman Geethanjali School of Electrical Engineering Department of Control and Automation VIT University, Vellore, Tamil Nadu, India Abstract: Myoelectric signals (MES have been used in various applications, in particular, for identification of user intention to potentially control assistive devices for amputees, orthotic devices, and exoskeleton in order to augment capability of the user. MES are also used to estimate force and, hence, torque to actuate the assistive device. The application of MES is not limited to assistive devices, and they also find potential applications in teleoperation of robots, haptic devices, virtual reality, and so on. The myoelectric control-based prosthetic hand aids to restore activities of daily living of amputees in order to improve the self-esteem of the user. All myoelectric control-based prosthetic hands may not have similar operations and exhibit variation in sensing input, deciphering the signals, and actuating prosthetic hand. Researchers are focusing on improving the functionality of prosthetic hand in order to suit the user requirement with the different operating features. The myoelectric control differs in operation to accommodate various external factors. This article reviews the state of the art of myoelectric prosthetic hand, giving description of each control strategy. Keywords: EMG, assistive device, amputee, myoelectric control, electric powered, body ­powered, bioelectric signal control

  6. Reconstruction of distal hand and foot defects with the free proximal peroneal artery perforator flap.

    Science.gov (United States)

    Scaglioni, Mario F; Kuo, Yur-Ren; Chen, Yen-Chou

    2016-03-01

    The proximal peroneal artery perforator (PPAP) flap is a reliable, thin fasciocutaneous flap. The purpose of this article was to report our experience with the use of free PPAP flaps for reconstruction of defects of the distal hand and foot. From November 2012 to September 2013, 9 patients received reconstruction with 10 free PPAP flaps. The defect locations included the big toe (2 cases), metatarsophalangeal joint (5 cases), dorsal finger (2 cases) and volar finger (1 case). Flaps were raised based on proximal peroneal perforator vessels without sacrificing the peroneal artery. The first dorsal metatarsal artery (5 cases) and digital artery (5 cases) were dissected as recipient vessels. The flap sizes varied from 2.5 x 2 cm to 9 x 5 cm. All of flaps were survival after surgery. One flap suffered from venous thrombosis and was successfully salvaged by performing a venous thrombectomy and vein graft. The donor sites were all primarily closed with minimal morbidities. Follow-up observations were conducted for 7 to 20 months, and all patients had good functional recovery with satisfying cosmetic results. Perforators arising from the peroneal artery in the proximal lateral leg can be used to design small, pliable fasciocutaneous flaps. Although the pedicle is short, the vessel diameter is adequate for microvascular anastomosis to the distal foot and hand recipient vessels. The free PPAP flap may be a good option for reconstructing distal hand and foot defects. © 2014 Wiley Periodicals, Inc.

  7. Mechanical design and control of a new myoelectric hand prosthesis

    NARCIS (Netherlands)

    Peerdeman, B.; Stramigioli, Stefano; Hekman, Edsko E.G.; Brouwer, Dannis Michel; Misra, Sarthak

    2011-01-01

    The development of modern, myoelectrically controlled hand prostheses can be difficult, due to the many requirements its mechanical design and control system need to fulfill [1]. The hand should be controllable with few input signals, while being able to perform a wide range of motions. It should be

  8. Fabrication, sensation and control of fluidic elastomer actuators and their application towards hand orthotics and prosthetics

    Science.gov (United States)

    Zhao, Huichan

    Due to their continuous and natural motion, fluidic elastomer actuators (FEAs) have shown potential in a range of robotic applications including prosthetics and orthotics. Despite their advantages and rapid developments, robots using these actuators still have several challenging issues to be addressed. First, the reliable production of low cost and complex actuators that can apply high forces is necessary, yet none of existing fabrication methods are both easy to implement and of high force output. Next, compliant or stretchable sensors that can be embedded into their bodies for sophisticated functions are required, however, many of these sensors suffer from hysteresis, fabrication complexity, chemical safety and environmental instability, and material incompatibility with soft actuators. Finally, feedback control for FEAs is necessary to achieve better performance, but most soft robots are still "open-loop". In this dissertation, I intend to help solve the above issues and drive the applications of soft robotics towards hand orthotics and prosthetics. First, I adapt rotational casting as a new manufacturing method for soft actuators. I present a cuboid soft actuator that can generate a force of >25 N at its tip, a near ten-fold increase over similar actuators previously reported. Next, I propose a soft orthotic finger with position control enabled via embedded optical fiber. I monitor both the static and dynamic states via the optical sensor and achieve the prescribed curvatures accurately and with stability by a gain-scheduled proportional-integral-derivative controller. Then I develop the soft orthotic fingers into a low-cost, closed-loop controlled, soft orthotic glove that can be worn by a typical human hand and helpful for grasping light objects, while also providing finger position control. I achieve motion control with inexpensive, binary pneumatic switches controlled by a simple finite-state-machine. Finally, I report the first use of stretchable optical

  9. Hand hygiene practices post ebola virus disease outbreak in a ...

    African Journals Online (AJOL)

    Introduction: Ebola virus disease (EVD) is a highly contagious viral infection that requires a high risk perception and practice of good hand hygiene by regular hand washing or use of hand sanitizers for infection control at all time. The declaration of Nigeria as an Ebola-free country by the World Health Organization on the ...

  10. [Implementation of precision control to achieve the goal of schistosomiasis elimination in China].

    Science.gov (United States)

    Zhou, Xiao-nong

    2016-02-01

    The integrated strategy for schistosomiasis control with focus on infectious source control, which has been implemented since 2004, accelerated the progress towards schistosomiasis control in China, and achieved transmission control of the disease across the country by the end of 2015, which achieved the overall objective of the Mid- and Long-term National Plan for Prevention and Control of Schistosomiasis (2004-2015) on schedule. Then, the goal of schistosomiasis elimination by 2025 was proposed in China in 2014. To achieve this new goal on schedule, we have to address the key issues, and implement precision control measures with more precise identification of control targets, so that we are able to completely eradicate the potential factors leading to resurgence of schistosomiasis transmission and enable the achievement of schistosomiasis elimination on schedule. Precision schistosomiasis control, a theoretical innovation of precision medicine in schistosomiasis control, will provide new insights into schistosomiasis control based on the conception of precision medicine. This paper describes the definition, interventions and the role of precision schistosomiasis control in the elimination of schistosomiasis in China, and demonstrates that sustainable improvement of professionals and integrated control capability at grass-root level is a prerequisite to the implementation of schistosomiasis control, precision schistosomiasis control is a key to the further implementation of the integrated strategy for schistosomiasis control with focus on infectious source control, and precision schistosomiasis control is a guarantee of curing schistosomiasis patients and implementing schistosomiasis control program and interventions.

  11. Principal components analysis based control of a multi-dof underactuated prosthetic hand

    Directory of Open Access Journals (Sweden)

    Magenes Giovanni

    2010-04-01

    Full Text Available Abstract Background Functionality, controllability and cosmetics are the key issues to be addressed in order to accomplish a successful functional substitution of the human hand by means of a prosthesis. Not only the prosthesis should duplicate the human hand in shape, functionality, sensorization, perception and sense of body-belonging, but it should also be controlled as the natural one, in the most intuitive and undemanding way. At present, prosthetic hands are controlled by means of non-invasive interfaces based on electromyography (EMG. Driving a multi degrees of freedom (DoF hand for achieving hand dexterity implies to selectively modulate many different EMG signals in order to make each joint move independently, and this could require significant cognitive effort to the user. Methods A Principal Components Analysis (PCA based algorithm is used to drive a 16 DoFs underactuated prosthetic hand prototype (called CyberHand with a two dimensional control input, in order to perform the three prehensile forms mostly used in Activities of Daily Living (ADLs. Such Principal Components set has been derived directly from the artificial hand by collecting its sensory data while performing 50 different grasps, and subsequently used for control. Results Trials have shown that two independent input signals can be successfully used to control the posture of a real robotic hand and that correct grasps (in terms of involved fingers, stability and posture may be achieved. Conclusions This work demonstrates the effectiveness of a bio-inspired system successfully conjugating the advantages of an underactuated, anthropomorphic hand with a PCA-based control strategy, and opens up promising possibilities for the development of an intuitively controllable hand prosthesis.

  12. Precision controlled atomic resolution scanning transmission electron microscopy using spiral scan pathways

    Science.gov (United States)

    Sang, Xiahan; Lupini, Andrew R.; Ding, Jilai; Kalinin, Sergei V.; Jesse, Stephen; Unocic, Raymond R.

    2017-03-01

    Atomic-resolution imaging in an aberration-corrected scanning transmission electron microscope (STEM) can enable direct correlation between atomic structure and materials functionality. The fast and precise control of the STEM probe is, however, challenging because the true beam location deviates from the assigned location depending on the properties of the deflectors. To reduce these deviations, i.e. image distortions, we use spiral scanning paths, allowing precise control of a sub-Å sized electron probe within an aberration-corrected STEM. Although spiral scanning avoids the sudden changes in the beam location (fly-back distortion) present in conventional raster scans, it is not distortion-free. “Archimedean” spirals, with a constant angular frequency within each scan, are used to determine the characteristic response at different frequencies. We then show that such characteristic functions can be used to correct image distortions present in more complicated constant linear velocity spirals, where the frequency varies within each scan. Through the combined application of constant linear velocity scanning and beam path corrections, spiral scan images are shown to exhibit less scan distortion than conventional raster scan images. The methodology presented here will be useful for in situ STEM imaging at higher temporal resolution and for imaging beam sensitive materials.

  13. A high precision dual feedback discrete control system designed for satellite trajectory simulator

    Science.gov (United States)

    Liu, Ximin; Liu, Liren; Sun, Jianfeng; Xu, Nan

    2005-08-01

    Cooperating with the free-space laser communication terminals, the satellite trajectory simulator is used to test the acquisition, pointing, tracking and communicating performances of the terminals. So the satellite trajectory simulator plays an important role in terminal ground test and verification. Using the double-prism, Sun etc in our group designed a satellite trajectory simulator. In this paper, a high precision dual feedback discrete control system designed for the simulator is given and a digital fabrication of the simulator is made correspondingly. In the dual feedback discrete control system, Proportional- Integral controller is used in velocity feedback loop and Proportional- Integral- Derivative controller is used in position feedback loop. In the controller design, simplex method is introduced and an improvement to the method is made. According to the transfer function of the control system in Z domain, the digital fabrication of the simulator is given when it is exposed to mechanism error and moment disturbance. Typically, when the mechanism error is 100urad, the residual standard error of pitching angle, azimuth angle, x-coordinate position and y-coordinate position are 0.49urad, 6.12urad, 4.56urad, 4.09urad respectively. When the moment disturbance is 0.1rad, the residual standard error of pitching angle, azimuth angle, x-coordinate position and y-coordinate position are 0.26urad, 0.22urad, 0.16urad, 0.15urad respectively. The digital fabrication results demonstrate that the dual feedback discrete control system designed for the simulator can achieve the anticipated high precision performance.

  14. Association of hand and arm disinfection with asthma control in US nurses.

    Science.gov (United States)

    Dumas, Orianne; Varraso, Raphäelle; Boggs, Krislyn M; Descatha, Alexis; Henneberger, Paul K; Quinot, Catherine; Speizer, Frank E; Zock, Jan-Paul; Le Moual, Nicole; Camargo, Carlos A

    2018-05-01

    To investigate the association between occupational exposure to disinfectants/antiseptics used for hand hygiene and asthma control in nurses. In 2014, we invited female nurses with asthma drawn from the Nurses' Health Study II to complete two supplemental questionnaires on their occupation and asthma (cross-sectional study, response rate: 80%). Among 4055 nurses (mean age: 59 years) with physician-diagnosed asthma and asthma medication use in the past year, we examined asthma control, as defined by the Asthma Control Test (ACT). Nurses were asked about the daily frequency of hand hygiene tasks: 'wash/scrub hands with disinfectants/hand sanitizers' (hand hygiene) and 'wash/scrub arms with disinfecting products' (surrogate of surgical hand/arm antisepsis). Analyses were adjusted for age, race, ethnicity, smoking status and body mass index. Nurses with partly controlled asthma (ACT: 20-24, 50%) and poorly controlled asthma (ACT ≤19, 18%) were compared with nurses with controlled asthma (ACT=25, 32%). In separate models, both hand and arm hygiene were associated with poorly controlled asthma. After mutual adjustment, only arm hygiene was associated with poorly controlled asthma: OR (95% CI) for arm hygiene tasks (never to >10 times/day) and poor asthma control. Associations persisted after further adjustment for surfaces/instruments disinfection tasks. Frequency of hand/arm hygiene tasks in nurses was associated with poor asthma control. The results suggest an adverse effect of products used for surgical hand/arm antisepsis. This potential new occupational risk factor for asthma warrants further study. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. High precision locating control system based on VCM for Talbot lithography

    Science.gov (United States)

    Yao, Jingwei; Zhao, Lixin; Deng, Qian; Hu, Song

    2016-10-01

    Aiming at the high precision and efficiency requirements of Z-direction locating in Talbot lithography, a control system based on Voice Coil Motor (VCM) was designed. In this paper, we built a math model of VCM and its moving characteristic was analyzed. A double-closed loop control strategy including position loop and current loop were accomplished. The current loop was implemented by driver, in order to achieve the rapid follow of the system current. The position loop was completed by the digital signal processor (DSP) and the position feedback was achieved by high precision linear scales. Feed forward control and position feedback Proportion Integration Differentiation (PID) control were applied in order to compensate for dynamic lag and improve the response speed of the system. And the high precision and efficiency of the system were verified by simulation and experiments. The results demonstrated that the performance of Z-direction gantry was obviously improved, having high precision, quick responses, strong real-time and easily to expend for higher precision.

  16. The Space Technology-7 Disturbance Reduction System Precision Control Flight Validation Experiment Control System Design

    Science.gov (United States)

    O'Donnell, James R.; Hsu, Oscar C.; Maghami, Peirman G.; Markley, F. Landis

    2006-01-01

    As originally proposed, the Space Technology-7 Disturbance Reduction System (DRS) project, managed out of the Jet Propulsion Laboratory, was designed to validate technologies required for future missions such as the Laser Interferometer Space Antenna (LISA). The two technologies to be demonstrated by DRS were Gravitational Reference Sensors (GRSs) and Colloidal MicroNewton Thrusters (CMNTs). Control algorithms being designed by the Dynamic Control System (DCS) team at the Goddard Space Flight Center would control the spacecraft so that it flew about a freely-floating GRS test mass, keeping it centered within its housing. For programmatic reasons, the GRSs were descoped from DRS. The primary goals of the new mission are to validate the performance of the CMNTs and to demonstrate precise spacecraft position control. DRS will fly as a part of the European Space Agency (ESA) LISA Pathfinder (LPF) spacecraft along with a similar ESA experiment, the LISA Technology Package (LTP). With no GRS, the DCS attitude and drag-free control systems make use of the sensor being developed by ESA as a part of the LTP. The control system is designed to maintain the spacecraft s position with respect to the test mass, to within 10 nm/the square root of Hz over the DRS science frequency band of 1 to 30 mHz.

  17. Application of high precision temperature control technology in infrared testing

    Science.gov (United States)

    Cao, Haiyuan; Cheng, Yong; Zhu, Mengzhen; Chu, Hua; Li, Wei

    2017-11-01

    In allusion to the demand of infrared system test, the principle of Infrared target simulator and the function of the temperature control are presented. The key technology of High precision temperature control is discussed, which include temperature gathering, PID control and power drive. The design scheme of temperature gathering is put forward. In order to reduce the measure error, discontinuously current and four-wire connection for the platinum thermal resistance are adopted. A 24-bits AD chip is used to improve the acquisition precision. Fuzzy PID controller is designed because of the large time constant and continuous disturbance of the environment temperature, which result in little overshoot, rapid response, high steady-state accuracy. Double power operational amplifiers are used to drive the TEC. Experiments show that the key performances such as temperature control precision and response speed meet the requirements.

  18. Lasers, Clocks and Drag-Free Control Exploration of Relativistic Gravity in Space

    CERN Document Server

    Dittus, Hansjorg; Turyshev, Slava G

    2008-01-01

    Over the next decade the gravitational physics community will benefit from dramatic improvements in many technologies critical to testing gravity. Highly accurate deep space navigation, interplanetary laser communication, interferometry and metrology, high precision frequency standards, precise pointing and attitude control, together with drag-free technologies, will revolutionize the field of experimental gravitational physics. The centennial of the general theory of relativity in 2015 will motivate a significant number of experiments designed to test this theory with unprecedented accuracy. The purpose of the contributions in this book, written by international experts, is to explore the possibilities for the next 20 years for conducting gravitational experiments in space that would utilize both entirely new and highly improved existing capabilities.

  19. Novel free-hand T1 pedicle screw method: Review of 44 consecutive cases

    Directory of Open Access Journals (Sweden)

    Mark A Rivkin

    2014-01-01

    Full Text Available Summary of Background Data: Multilevel posterior cervical instrumented fusions are becoming more prevalent in current practice. Biomechanical characteristics of the cervicothoracic junction may necessitate extending the construct to upper thoracic segments. However, fixation in upper thoracic spine can be technically demanding owing to transitional anatomy while suboptimal placement facilitates vascular and neurologic complications. Thoracic instrumentation methods include free-hand, fluoroscopic guidance, and CT-based image guidance. However, fluoroscopy of upper thoracic spine is challenging secondary to vertebral geometry and patient positioning, while image-guided systems present substantial financial commitment and are not readily available at most centers. Additionally, imaging modalities increase radiation exposure to the patient and surgeon while potentially lengthening surgical time. Materials and Methods: Retrospective review of 44 consecutive patients undergoing a cervicothoracic fusion by a single surgeon using the novel free-hand T1 pedicle screw technique between June 2009 and November 2012. A starting point medial and cephalad to classic entry as well as new trajectory were utilized. No imaging modalities were employed during screw insertion. Postoperative CT scans were obtained on day 1. Screw accuracy was independently evaluated according to the Heary classification. Results: In total, 87 pedicle screws placed were at T1. Grade 1 placement occurred in 72 (82.8% screws, Grade 2 in 4 (4.6% screws and Grade 3 in 9 (10.3% screws. All Grade 2 and 3 breaches were <2 mm except one Grade 3 screw breaching 2-4 mm laterally. Only two screws (2.3% were noted to be Grade 4, both breaching medially by less than 2 mm. No new neurological deficits or returns to operating room took place postoperatively. Conclusions: This modification of the traditional starting point and trajectory at T1 is safe and effective. It attenuates additional bone

  20. Automatic gain control of neural coupling during cooperative hand movements.

    Science.gov (United States)

    Thomas, F A; Dietz, V; Schrafl-Altermatt, M

    2018-04-13

    Cooperative hand movements (e.g. opening a bottle) are controlled by a task-specific neural coupling, reflected in EMG reflex responses contralateral to the stimulation site. In this study the contralateral reflex responses in forearm extensor muscles to ipsilateral ulnar nerve stimulation was analyzed at various resistance and velocities of cooperative hand movements. The size of contralateral reflex responses was closely related to the level of forearm muscle activation required to accomplish the various cooperative hand movement tasks. This indicates an automatic gain control of neural coupling that allows a rapid matching of corrective forces exerted at both sides of an object with the goal 'two hands one action'.

  1. The first step in infection control is hand hygiene.

    Science.gov (United States)

    Canham, Leslie

    2011-01-01

    A dental health care worker (DHCW) has an obligation to prevent the spread of health care associated infections. Adhering to proper hand hygiene procedures, selecting appropriate hand hygiene products and the use of gloves are all important elements of infection control. The CDC Guidelines for Hand Hygiene state that improved hand hygiene practices can reduce transmission of pathogenic microorganisms to patients and personnel in health care settings. DHCWs must also protect themselves by recognizing pitfalls such as irritants or allergies that may pose obstacles to proper hand hygiene. Occupational irritants and allergies can be caused by frequent hand washing, exposure to hand hygiene products, exposure to chemicals and shear forces associated with wearing or removing gloves. Since the primary defense against infection and transmission of pathogens is healthy, unbroken skin, DHCWs must take steps to ensure that their skin remains healthy and intact. These steps include evaluating different types of hand hygiene products, lotions and gloves for the best compatibility. If the DHCW sees a breakdown of his or her skin barrier, steps should be taken to determine the cause and remedy. Remedies can include the use of alcohol-based hand sanitizers containing emollients and moisturizers and regular use of a medical grade hand lotion. The bottom line: healthy skin protects you at work and at home. Selection and use of appropriate hand hygiene products, including moisturizers, are an essential part ofa dental office infection control program. My coworker lost the use of her thumb for several months due to complications of a staph infection. She was unable to work and found even simple tasks such as closing a button hard to do. Think of how difficult your work would be if something happened to your hands. Injury, irritation or allergies could alter your ability to work or even perform routine tasks. Our hands provide us with the ability to work in clinical dentistry. It makes

  2. A synergy-based hand control is encoded in human motor cortical areas

    Science.gov (United States)

    Leo, Andrea; Handjaras, Giacomo; Bianchi, Matteo; Marino, Hamal; Gabiccini, Marco; Guidi, Andrea; Scilingo, Enzo Pasquale; Pietrini, Pietro; Bicchi, Antonio; Santello, Marco; Ricciardi, Emiliano

    2016-01-01

    How the human brain controls hand movements to carry out different tasks is still debated. The concept of synergy has been proposed to indicate functional modules that may simplify the control of hand postures by simultaneously recruiting sets of muscles and joints. However, whether and to what extent synergic hand postures are encoded as such at a cortical level remains unknown. Here, we combined kinematic, electromyography, and brain activity measures obtained by functional magnetic resonance imaging while subjects performed a variety of movements towards virtual objects. Hand postural information, encoded through kinematic synergies, were represented in cortical areas devoted to hand motor control and successfully discriminated individual grasping movements, significantly outperforming alternative somatotopic or muscle-based models. Importantly, hand postural synergies were predicted by neural activation patterns within primary motor cortex. These findings support a novel cortical organization for hand movement control and open potential applications for brain-computer interfaces and neuroprostheses. DOI: http://dx.doi.org/10.7554/eLife.13420.001 PMID:26880543

  3. Control of a Robotic Hand Using a Tongue Control System-A Prosthesis Application.

    Science.gov (United States)

    Johansen, Daniel; Cipriani, Christian; Popovic, Dejan B; Struijk, Lotte N S A

    2016-07-01

    The aim of this study was to investigate the feasibility of using an inductive tongue control system (ITCS) for controlling robotic/prosthetic hands and arms. This study presents a novel dual modal control scheme for multigrasp robotic hands combining standard electromyogram (EMG) with the ITCS. The performance of the ITCS control scheme was evaluated in a comparative study. Ten healthy subjects used both the ITCS control scheme and a conventional EMG control scheme to complete grasping exercises with the IH1 Azzurra robotic hand implementing five grasps. Time to activate a desired function or grasp was used as the performance metric. Statistically significant differences were found when comparing the performance of the two control schemes. On average, the ITCS control scheme was 1.15 s faster than the EMG control scheme, corresponding to a 35.4% reduction in the activation time. The largest difference was for grasp 5 with a mean AT reduction of 45.3% (2.38 s). The findings indicate that using the ITCS control scheme could allow for faster activation of specific grasps or functions compared with a conventional EMG control scheme. For transhumeral and especially bilateral amputees, the ITCS control scheme could have a significant impact on the prosthesis control. In addition, the ITCS would provide bilateral amputees with the additional advantage of environmental and computer control for which the ITCS was originally developed.

  4. Cognitive vision system for control of dexterous prosthetic hands: Experimental evaluation

    Directory of Open Access Journals (Sweden)

    Došen Strahinja

    2010-08-01

    Full Text Available Abstract Background Dexterous prosthetic hands that were developed recently, such as SmartHand and i-LIMB, are highly sophisticated; they have individually controllable fingers and the thumb that is able to abduct/adduct. This flexibility allows implementation of many different grasping strategies, but also requires new control algorithms that can exploit the many degrees of freedom available. The current study presents and tests the operation of a new control method for dexterous prosthetic hands. Methods The central component of the proposed method is an autonomous controller comprising a vision system with rule-based reasoning mounted on a dexterous hand (CyberHand. The controller, termed cognitive vision system (CVS, mimics biological control and generates commands for prehension. The CVS was integrated into a hierarchical control structure: 1 the user triggers the system and controls the orientation of the hand; 2 a high-level controller automatically selects the grasp type and size; and 3 an embedded hand controller implements the selected grasp using closed-loop position/force control. The operation of the control system was tested in 13 healthy subjects who used Cyberhand, attached to the forearm, to grasp and transport 18 objects placed at two different distances. Results The system correctly estimated grasp type and size (nine commands in total in about 84% of the trials. In an additional 6% of the trials, the grasp type and/or size were different from the optimal ones, but they were still good enough for the grasp to be successful. If the control task was simplified by decreasing the number of possible commands, the classification accuracy increased (e.g., 93% for guessing the grasp type only. Conclusions The original outcome of this research is a novel controller empowered by vision and reasoning and capable of high-level analysis (i.e., determining object properties and autonomous decision making (i.e., selecting the grasp type and

  5. Knowledge and attitude toward smoke-free legislation and second-hand smoking exposure among workers in indoor bars, beer parlors and discotheques in Osun State of Nigeria.

    Science.gov (United States)

    Onigbogi, Olanrewaju Olusola; Odukoya, Oluwakemi; Onigbogi, Modupe; Sekoni, Oluwakemi

    2015-04-01

    One of the requirements of the Osun State smoke-free legislation is to ensure smoke-free enclosed and partially enclosed workplaces. This survey was conducted to assess the knowledge and attitude of workers in indoor bars, beer parlors and discotheques to smoke-free legislation in general and the Osun State smoke-free law in particular. A convenience sampling of 36 hospitality centers was conducted. Interviewer-administered questionnaires were used to elicit responses about the objectives from non-smoking workers. The questionnaires had sections on knowledge of the Osun State smoke-free law, attitude toward the law and smoke-free legislation in general and exposure to second-hand tobacco smoke by the workers. Questions were also asked about the second-hand tobacco smoking status of these workers. The data were analyzed using SPSS version 15.0. We had 154 participants recruited into the study. There were 75 males (48.0%) and 79 females (52.0%). On the overall, respondents had a good knowledge of the effects of second-hand smoke on health (70.2%) with 75.0% of them being aware of the general smoke-free law and 67.3% being aware of the Osun State smoke-free law although none of them had ever seen a copy of the law. A high proportion (60.0%) was in support of the Osun smoke-free law although all of them think that the implementation of the law could reduce patronage and jeopardize their income. Attitude toward second-hand smoking was generally positive with 72.0% of them having no tolerance for second-hand tobacco smoke in their homes. Most participants (95.5%) had been exposed to tobacco smoke in the workplace within the past week. Despite the high level of awareness of the respondents about the dangers of second hand smoke and their positive attitude to smoke-free laws, nearly all were constantly being exposed to second hand smoke at work. This calls for policy level interventions to improve the implementation of the smoke-free law.

  6. Hand-held medical robots.

    Science.gov (United States)

    Payne, Christopher J; Yang, Guang-Zhong

    2014-08-01

    Medical robots have evolved from autonomous systems to tele-operated platforms and mechanically-grounded, cooperatively-controlled robots. Whilst these approaches have seen both commercial and clinical success, uptake of these robots remains moderate because of their high cost, large physical footprint and long setup times. More recently, researchers have moved toward developing hand-held robots that are completely ungrounded and manipulated by surgeons in free space, in a similar manner to how conventional instruments are handled. These devices provide specific functions that assist the surgeon in accomplishing tasks that are otherwise challenging with manual manipulation. Hand-held robots have the advantages of being compact and easily integrated into the normal surgical workflow since there is typically little or no setup time. Hand-held devices can also have a significantly reduced cost to healthcare providers as they do not necessitate the complex, multi degree-of-freedom linkages that grounded robots require. However, the development of such devices is faced with many technical challenges, including miniaturization, cost and sterility, control stability, inertial and gravity compensation and robust instrument tracking. This review presents the emerging technical trends in hand-held medical robots and future development opportunities for promoting their wider clinical uptake.

  7. Fusion of hard and soft control strategies for the robotic hand

    CERN Document Server

    Chen, Cheng-Hung

    2018-01-01

    Long considered the stuff of science fiction, a prosthetic hand capable of fully replicating all of that appendage's various functions is closer to becoming reality than ever before. This book provides a comprehensive report on exciting recent developments in hybrid control techniques—one of the most crucial hurdles to be overcome in creating smart prosthetic hands. Coauthored by two of the world's foremost pioneering experts in the field, Fusion of Hard and Soft Control Strategies for the Robotic Hand treats robotic hands for multiple applications. It begins with an overview of advances in main control techniques that have been made over the past decade before addressing the military context for affordable robotic hand technology with tactile and/or proprioceptive feedback for hand amputees. Kinematics, homogene us transformations, inverse and differential kinematics, trajectory planning, and dynamic models of two-link thumb and three-link index finger are discussed in detail. The remainder of the book is...

  8. Structural Integration and Control of Peerless Human-like Prosthetic Hand

    Science.gov (United States)

    Dave, Ankit; Muthu, P.; Karthikraj, V.; Latha, S.

    2018-04-01

    Limb damage can create severe disturbance in movement and operative abilities wherein the prosthetic rehabilitation has the potential to replace function and enhance the quality of life. This paper presents a humanlike prosthetic hand using such unique design concept of hand model using artificial bones, ligaments, and tendons controlled using Arduino. Amongst various platforms available, Arduino is known for its adaptability, adoration and low cost. The design of prosthetic hand has a unique structure with all carpal, metacarpal, and phalanges which are bones of the hand. These bones are attached to each other following the pattern of human hand using the polymeric rubber as a functioning ligament. Furthermore, this structure of finger is driven by tendons attached to all fingers and passes through the ligaments working as pulley resulting in more degrees of freedom. The motor can twitch the tendons to achieve the action of fingers. Thus the servos, controlled by an Arduino, are used to regulate the movement mechanism of the prosthetic hand.

  9. Three-dimensional surgical modelling with an open-source software protocol: study of precision and reproducibility in mandibular reconstruction with the fibula free flap.

    Science.gov (United States)

    Ganry, L; Quilichini, J; Bandini, C M; Leyder, P; Hersant, B; Meningaud, J P

    2017-08-01

    Very few surgical teams currently use totally independent and free solutions to perform three-dimensional (3D) surgical modelling for osseous free flaps in reconstructive surgery. This study assessed the precision and technical reproducibility of a 3D surgical modelling protocol using free open-source software in mandibular reconstruction with fibula free flaps and surgical guides. Precision was assessed through comparisons of the 3D surgical guide to the sterilized 3D-printed guide, determining accuracy to the millimetre level. Reproducibility was assessed in three surgical cases by volumetric comparison to the millimetre level. For the 3D surgical modelling, a difference of less than 0.1mm was observed. Almost no deformations (free flap modelling was between 0.1mm and 0.4mm, and the average precision of the complete reconstructed mandible was less than 1mm. The open-source software protocol demonstrated high accuracy without complications. However, the precision of the surgical case depends on the surgeon's 3D surgical modelling. Therefore, surgeons need training on the use of this protocol before applying it to surgical cases; this constitutes a limitation. Further studies should address the transfer of expertise. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Electromyogram synergy control of a dexterous artificial hand to unscrew and screw objects.

    Science.gov (United States)

    Kent, Benjamin A; Karnati, Nareen; Engeberg, Erik D

    2014-03-21

    Due to their limited dexterity, it is currently not possible to use a commercially available prosthetic hand to unscrew or screw objects without using elbow and shoulder movements. For these tasks, prosthetic hands function like a wrench, which is unnatural and limits their use in tight working environments. Results from timed rotational tasks with human subjects demonstrate the clinical need for increased dexterity of prosthetic hands, and a clinically viable solution to this problem is presented for an anthropomorphic artificial hand. Initially, a human hand motion analysis was performed during a rotational task. From these data, human hand synergies were derived and mapped to an anthropomorphic artificial hand. The synergy for the artificial hand is controlled using conventional dual site electromyogram (EMG) signals. These EMG signals were mapped to the developed synergy to control four joints of the dexterous artificial hand simultaneously.Five limb absent and ten able-bodied test subjects participated in a comparison study to complete a timed rotational task as quickly as possible with their natural hands (except for one subject with a bilateral hand absence), eight commercially available prosthetic hands, and the proposed synergy controller. Each test subject used two to four different artificial hands. With the able-bodied subjects, the developed synergy controller reduced task completion time by 177% on average. The limb absent subjects completed the task faster on average than with their own prostheses by 46%. There was a statistically significant improvement in task completion time with the synergy controller for three of the four limb absent participants with integrated prostheses, and was not statistically different for the fourth. The proposed synergy controller reduced average task completion time compared to commercially available prostheses. Additionally, the synergy controller is able to function in a small workspace and requires less physical

  11. Precision grip in congenital and acquired hemiparesis: similarities in impairments and implications for neurorehabilitation - review

    Directory of Open Access Journals (Sweden)

    Yannick eBleyenheuft

    2014-06-01

    Full Text Available Background: Patients with congenital and acquired hemiparesis incur long-term functional deficits, among which the loss of prehension that may impact their functional independence. Identifying, understanding and comparing the underlying mechanisms of prehension impairments represent an opportunity to better adapt neurorehabilitationObjective: The present review aims to provide a better understanding of precision grip deficits in congenital and acquired hemiparesis and to determine whether the severity and type of fine motor control impairments depend on whether or not the lesions are congenital or acquired in adulthood. Methods: Using combinations of the following key words: fingertip force, grip force, precision grip, cerebral palsy, stroke, pubmed and Scopus databases were used to search studies from 1984 to 2013. Results: Individuals with both congenital and acquired hemiparesis were able to some extent to use anticipatory motor control in precision grip tasks, even if this control was impaired in the paretic hand. In both congenital or acquired hemiparesis, the ability to plan efficient anticipatory motor control when the less-affected hand is used provides a possibility to remediate impairments in anticipatory motor control of the paretic hand. Conclusion: Surprisingly we observed very few differences between the results of studies in children with congenital hemiplegia and stroke patients. We suggest that the underlying specific strategies of neurorehabilitation developed for each one could benefit the other.

  12. Viability of Controlling Prosthetic Hand Utilizing Electroencephalograph (EEG) Dataset Signal

    Science.gov (United States)

    Miskon, Azizi; A/L Thanakodi, Suresh; Raihan Mazlan, Mohd; Mohd Haziq Azhar, Satria; Nooraya Mohd Tawil, Siti

    2016-11-01

    This project presents the development of an artificial hand controlled by Electroencephalograph (EEG) signal datasets for the prosthetic application. The EEG signal datasets were used as to improvise the way to control the prosthetic hand compared to the Electromyograph (EMG). The EMG has disadvantages to a person, who has not used the muscle for a long time and also to person with degenerative issues due to age factor. Thus, the EEG datasets found to be an alternative for EMG. The datasets used in this work were taken from Brain Computer Interface (BCI) Project. The datasets were already classified for open, close and combined movement operations. It served the purpose as an input to control the prosthetic hand by using an Interface system between Microsoft Visual Studio and Arduino. The obtained results reveal the prosthetic hand to be more efficient and faster in response to the EEG datasets with an additional LiPo (Lithium Polymer) battery attached to the prosthetic. Some limitations were also identified in terms of the hand movements, weight of the prosthetic, and the suggestions to improve were concluded in this paper. Overall, the objective of this paper were achieved when the prosthetic hand found to be feasible in operation utilizing the EEG datasets.

  13. Design and implementation of adaptive inverse control algorithm for a micro-hand control system

    Directory of Open Access Journals (Sweden)

    Wan-Cheng Wang

    2014-01-01

    Full Text Available The Letter proposes an online tuned adaptive inverse position control algorithm for a micro-hand. First, the configuration of the micro-hand is discussed. Next, a kinematic analysis of the micro-hand is investigated and then the relationship between the rotor position of micro-permanent magnet synchronous motor and the tip of the micro-finger is derived. After that, an online tuned adaptive inverse control algorithm, which includes an adaptive inverse model and an adaptive inverse control, is designed. The online tuned adaptive inverse control algorithm has better performance than the proportional–integral control algorithm does. In addition, to avoid damaging the object during the grasping process, an online force control algorithm is proposed here as well. An embedded micro-computer, cRIO-9024, is used to realise the whole position control algorithm and the force control algorithm by using software. As a result, the hardware circuit is very simple. Experimental results show that the proposed system can provide fast transient responses, good load disturbance responses, good tracking responses and satisfactory grasping responses.

  14. A common control signal and a ballistic stage can explain the control of coordinated eye-hand movements.

    Science.gov (United States)

    Gopal, Atul; Murthy, Aditya

    2016-06-01

    Voluntary control has been extensively studied in the context of eye and hand movements made in isolation, yet little is known about the nature of control during eye-hand coordination. We probed this with a redirect task. Here subjects had to make reaching/pointing movements accompanied by coordinated eye movements but had to change their plans when the target occasionally changed its position during some trials. Using a race model framework, we found that separate effector-specific mechanisms may be recruited to control eye and hand movements when executed in isolation but when the same effectors are coordinated a unitary mechanism to control coordinated eye-hand movements is employed. Specifically, we found that performance curves were distinct for the eye and hand when these movements were executed in isolation but were comparable when they were executed together. Second, the time to switch motor plans, called the target step reaction time, was different in the eye-alone and hand-alone conditions but was similar in the coordinated condition under assumption of a ballistic stage of ∼40 ms, on average. Interestingly, the existence of this ballistic stage could predict the extent of eye-hand dissociations seen in individual subjects. Finally, when subjects were explicitly instructed to control specifically a single effector (eye or hand), redirecting one effector had a strong effect on the performance of the other effector. Taken together, these results suggest that a common control signal and a ballistic stage are recruited when coordinated eye-hand movement plans require alteration. Copyright © 2016 the American Physiological Society.

  15. Precision Force Control for an Electro-Hydraulic Press Machine

    Directory of Open Access Journals (Sweden)

    Hong-Ming Chen

    2014-08-01

    Full Text Available This thesis is primarily intended to design a PC-based control system to control the force of an electro-hydraulic servo press system for implementing precision force control. The main feature is to develop a composite control by using the relief valve and the flow servo valve. Using feedback from a force sensor, a fuzzy controller was designed with LabVIEW software as the system control core for achieving a precision force control for the hydraulic cylinder on its travel and output. The weakness of hydraulic systems is that hydraulic oil is compressible and prone to leaking, and its characteristics can vary with oil temperature, thus making it difficult for a general linear controller to achieve accurate control. Therefore, a fuzzy controller was designed with LabVIEW along with a NI-PCI_6221 interface card and a load cell to control the servo valve flow and the relief valve to control the pressure source. The testing results indicate that accurate force control output of an electro-hydraulic servo press system can be obtained.

  16. Washing away your sins will set your mind free: physical cleansing modulates the effect of threatened morality on executive control.

    Science.gov (United States)

    Kalanthroff, Eyal; Aslan, Chen; Dar, Reuven

    2017-01-01

    The effect of threatened morality on negative emotions and on altruistic behaviour has been shown to diminish following physical cleansing (hand-washing). We hypothesised that threatened morality will broadly impair the executive control system, and that physical cleansing will moderate this detrimental effect. Thirty-seven participants were asked to write about an immoral deed they had committed, whereupon half of them were allowed to wipe their hands. Three executive control tasks-Stroop, stop-signal, and object interference-were then administered to all participants. Participants who had not wiped their hands, but not those who did, demonstrated impaired performance, compared to hand-washing controls, in all three tasks. We conclude that threatened morality has a detrimental effect on executive control, specifically on conflict monitoring and response inhibition, and that physical cleansing "frees" this system, counteracting the detrimental effects of morality threats. We discuss possible implications for obsessive-compulsive disorder, which is characterised by deficient executive control and in which both threatened morality and physical cleansing are central concerns.

  17. (In)Visible Hand(s)

    OpenAIRE

    Predrag Zima

    2007-01-01

    In this paper, the author discusses the regulatory role of the state and legal norms, in market economy, especially in so-called transition countries. Legal policy, and other questions of the state and free market economy are here closely connected, because the state must ensure with legal norms that economic processes are not interrupted: only the state can establish the legal basis for a market economy. The free market’s invisible hand is acting in questions such as: what is to be produced,...

  18. Precise measurements and shimming of magnetic field gradients in the low field regime

    Energy Technology Data Exchange (ETDEWEB)

    Allmendinger, Fabian; Schmidt, Ulrich [Physikalisches Institut, Universitaet Heidelberg (Germany); Grasdijk, Olivier; Jungmann, Klaus; Willmann, Lorenz [University of Groningen (Netherlands); Heil, Werner; Karpuk, Sergei; Repetto, Maricel; Sobolev, Yuri; Zimmer, Stefan [Institut fuer Physik, Universitaet Mainz (Germany); Krause, Hans-Joachim; Offenhaeuser, Andreas [Peter Gruenberg Institut, Forschungszentrum Juelich (Germany); Collaboration: MIXed-Collaboration

    2016-07-01

    For many experiments at the precision frontier of fundamental physics, the accurate measurement and knowledge of magnetic field gradients in particular in the low field regime (<μT) is a necessity: On the one hand, in the search for an Electric Dipole Moment (EDM) of free neutrons or atoms, field gradients contribute to geometric-phase-induced false EDM signals for particles in traps. On the other hand, clock comparison experiments like the {sup 3}He/{sup 129}Xe spin clock experiment suffer from gradients, since the coherent T{sub 2}*-time of free spin precession, and thus the measurement sensitivity, scales ∝ ∇ vector B{sup -2}. Here we report on a new and very effective method, to shim and to measure tiny magnetic field gradients in the range of pT/cm by using effective T{sub 2}*-measurement sequences in varying the currents of trim coils of known geometry.

  19. Precise Localization and Control of Catalytic Janus Micromotors using Weak Magnetic Fields

    NARCIS (Netherlands)

    Khalil, Islam S. M.; Magdanz, Veronika; Sanchez, Samuel; Schmidt, Oliver G.; Misra, Sarthak

    2015-01-01

    We experimentally demonstrate the precise localization of spherical Pt-Silica Janus micromotors (diameter 5 mu m) under the influence of controlled magnetic fields. First, we control the motion of the Janus micromotors in two-dimensional (2D) space. The control system achieves precise localization

  20. High Precision Current Control for the LHC Main Power Converters

    CERN Document Server

    Thiesen, H; Hudson, G; King, Q; Montabonnet, V; Nisbet, D; Page, S

    2010-01-01

    Since restarting at the end of 2009, the LHC has reached a new energy record in March 2010 with the two 3.5 TeV beams. To achieve the performance required for the good functioning of the accelerator, the currents in the main circuits (Main Bends and Main Quadrupoles) must be controlled with a higher precision than ever previously requested for a particle accelerator at CERN: a few parts per million (ppm) of nominal current. This paper describes the different challenges that were overcome to achieve the required precision for the current control of the main circuits. Precision tests performed during the hardware commissioning of the LHC illustrate this paper.

  1. A Prosthetic Hand Body Area Controller Based on Efficient Pattern Recognition Control Strategies.

    Science.gov (United States)

    Benatti, Simone; Milosevic, Bojan; Farella, Elisabetta; Gruppioni, Emanuele; Benini, Luca

    2017-04-15

    Poliarticulated prosthetic hands represent a powerful tool to restore functionality and improve quality of life for upper limb amputees. Such devices offer, on the same wearable node, sensing and actuation capabilities, which are not equally supported by natural interaction and control strategies. The control in state-of-the-art solutions is still performed mainly through complex encoding of gestures in bursts of contractions of the residual forearm muscles, resulting in a non-intuitive Human-Machine Interface (HMI). Recent research efforts explore the use of myoelectric gesture recognition for innovative interaction solutions, however there persists a considerable gap between research evaluation and implementation into successful complete systems. In this paper, we present the design of a wearable prosthetic hand controller, based on intuitive gesture recognition and a custom control strategy. The wearable node directly actuates a poliarticulated hand and wirelessly interacts with a personal gateway (i.e., a smartphone) for the training and personalization of the recognition algorithm. Through the whole system development, we address the challenge of integrating an efficient embedded gesture classifier with a control strategy tailored for an intuitive interaction between the user and the prosthesis. We demonstrate that this combined approach outperforms systems based on mere pattern recognition, since they target the accuracy of a classification algorithm rather than the control of a gesture. The system was fully implemented, tested on healthy and amputee subjects and compared against benchmark repositories. The proposed approach achieves an error rate of 1.6% in the end-to-end real time control of commonly used hand gestures, while complying with the power and performance budget of a low-cost microcontroller.

  2. Inter-Tester Reliability and Precision of Manual Muscle Testing and Hand-Held Dynamometry in Lower Limb Muscles of Children with Spina Bifida

    Science.gov (United States)

    Mahony, Kate; Hunt, Adrienne; Daley, Deborah; Sims, Susan; Adams, Roger

    2009-01-01

    Reliability and measurement precision of manual muscle testing (MMT) and hand-held dynamometry (HHD) were compared for children with spina bifida. Strength measures were obtained of the hip flexors, hip abductors, and knee extensors of 20 children (10 males, 10 females; mean age 9 years 10 months; range: 5 to 15 years) by two experienced physical…

  3. Early intensive hand rehabilitation after spinal cord injury ("Hands On": a protocol for a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Hsueh Ya-Seng

    2011-01-01

    Full Text Available Abstract Background Loss of hand function is one of the most devastating consequences of spinal cord injury. Intensive hand training provided on an instrumented exercise workstation in conjunction with functional electrical stimulation may enhance neural recovery and hand function. The aim of this trial is to compare usual care with an 8-week program of intensive hand training and functional electrical stimulation. Methods/design A multicentre randomised controlled trial will be undertaken. Seventy-eight participants with recent tetraplegia (C2 to T1 motor complete or incomplete undergoing inpatient rehabilitation will be recruited from seven spinal cord injury units in Australia and New Zealand and will be randomised to a control or experimental group. Control participants will receive usual care. Experimental participants will receive usual care and an 8-week program of intensive unilateral hand training using an instrumented exercise workstation and functional electrical stimulation. Participants will drive the functional electrical stimulation of their target hands via a behind-the-ear bluetooth device, which is sensitive to tooth clicks. The bluetooth device will enable the use of various manipulanda to practice functional activities embedded within computer-based games and activities. Training will be provided for one hour, 5 days per week, during the 8-week intervention period. The primary outcome is the Action Research Arm Test. Secondary outcomes include measurements of strength, sensation, function, quality of life and cost effectiveness. All outcomes will be taken at baseline, 8 weeks, 6 months and 12 months by assessors blinded to group allocation. Recruitment commenced in December 2009. Discussion The results of this trial will determine the effectiveness of an 8-week program of intensive hand training with functional electrical stimulation. Trial registration NCT01086930 (12th March 2010 ACTRN12609000695202 (12th August 2009

  4. Early intensive hand rehabilitation after spinal cord injury ("Hands On"): a protocol for a randomised controlled trial.

    Science.gov (United States)

    Harvey, Lisa A; Dunlop, Sarah A; Churilov, Leonid; Hsueh, Ya-Seng Arthur; Galea, Mary P

    2011-01-17

    Loss of hand function is one of the most devastating consequences of spinal cord injury. Intensive hand training provided on an instrumented exercise workstation in conjunction with functional electrical stimulation may enhance neural recovery and hand function. The aim of this trial is to compare usual care with an 8-week program of intensive hand training and functional electrical stimulation. A multicentre randomised controlled trial will be undertaken. Seventy-eight participants with recent tetraplegia (C2 to T1 motor complete or incomplete) undergoing inpatient rehabilitation will be recruited from seven spinal cord injury units in Australia and New Zealand and will be randomised to a control or experimental group. Control participants will receive usual care. Experimental participants will receive usual care and an 8-week program of intensive unilateral hand training using an instrumented exercise workstation and functional electrical stimulation. Participants will drive the functional electrical stimulation of their target hands via a behind-the-ear bluetooth device, which is sensitive to tooth clicks. The bluetooth device will enable the use of various manipulanda to practice functional activities embedded within computer-based games and activities. Training will be provided for one hour, 5 days per week, during the 8-week intervention period. The primary outcome is the Action Research Arm Test. Secondary outcomes include measurements of strength, sensation, function, quality of life and cost effectiveness. All outcomes will be taken at baseline, 8 weeks, 6 months and 12 months by assessors blinded to group allocation. Recruitment commenced in December 2009. The results of this trial will determine the effectiveness of an 8-week program of intensive hand training with functional electrical stimulation. NCT01086930 (12th March 2010)ACTRN12609000695202 (12th August 2009).

  5. Concept for a large master/slave-controlled robotic hand

    Science.gov (United States)

    Grissom, William A.; Abdallah, Mahmoud A.; White, Carl L.

    1988-01-01

    A strategy is presented for the design and construction of a large master/slave-controlled, five-finger robotic hand. Each of the five fingers will possess four independent axes each driven by a brushless DC servomotor and, thus, four degrees-of-freedom. It is proposed that commercially available components be utilized as much as possible to fabricate a working laboratory model of the device with an anticipated overall length of two-to-four feet (0.6 to 1.2 m). The fingers are to be designed so that proximity, tactile, or force/torque sensors can be imbedded in their structure. In order to provide for the simultaneous control of the twenty independent hand joints, a multilevel master/slave control strategy is proposed in which the operator wears a specially instrumented glove which produces control signals corresponding to the finger configurations and which is capable of conveying sensor feedback signals to the operator. Two dexterous hand master devices are currently commercially available for this application with both undergoing continuing development. A third approach to be investigated for the master control mode is the use of real-time image processing of a specially patterned master glove to provide the respective control signals for positioning the multiple finger joints.

  6. Model-free control

    Science.gov (United States)

    Fliess, Michel; Join, Cédric

    2013-12-01

    'Model-free control'and the corresponding 'intelligent' PID controllers (iPIDs), which already had many successful concrete applications, are presented here for the first time in an unified manner, where the new advances are taken into account. The basics of model-free control is now employing some old functional analysis and some elementary differential algebra. The estimation techniques become quite straightforward via a recent online parameter identification approach. The importance of iPIs and especially of iPs is deduced from the presence of friction. The strange industrial ubiquity of classic PIDs and the great difficulty for tuning them in complex situations is deduced, via an elementary sampling, from their connections with iPIDs. Several numerical simulations are presented which include some infinite-dimensional systems. They demonstrate not only the power of our intelligent controllers but also the great simplicity for tuning them.

  7. Effects of Isometric Hand-Grip Muscle Contraction on Young Adults' Free Recall and Recognition Memory

    Science.gov (United States)

    Tomporowski, Phillip D.; Albrecht, Chelesa; Pendleton, Daniel M.

    2017-01-01

    Purpose: The purpose of this study was to determine if physical arousal produced by isometric hand-dynamometer contraction performed during word-list learning affects young adults' free recall or recognition memory. Method: Twenty-four young adults (12 female; M[subscript age] = 22 years) were presented with 4 20-item word lists. Moderate arousal…

  8. Knowledge and Attitude toward Smoke-Free Legislation and Second-Hand Smoking Exposure among Workers in Indoor Bars, Beer Parlors and Discotheques in Osun State of Nigeria

    Directory of Open Access Journals (Sweden)

    Olanrewaju Olusola Onigbogi

    2015-04-01

    Full Text Available Background One of the requirements of the Osun State smoke-free legislation is to ensure smoke-free enclosed and partially enclosed workplaces. This survey was conducted to assess the knowledge and attitude of workers in indoor bars, beer parlors and discotheques to smoke-free legislation in general and the Osun State smoke-free law in particular. Methods A convenience sampling of 36 hospitality centers was conducted. Interviewer-administered questionnaires were used to elicit responses about the objectives from non-smoking workers. The questionnaires had sections on knowledge of the Osun State smoke-free law, attitude toward the law and smoke-free legislation in general and exposure to second-hand tobacco smoke by the workers. Questions were also asked about the secondhand tobacco smoking status of these workers. The data were analyzed using SPSS version 15.0. Results We had 154 participants recruited into the study. There were 75 males (48.0% and 79 females (52.0%. On the overall, respondents had a good knowledge of the effects of second-hand smoke on health (70.2% with 75.0% of them being aware of the general smoke-free law and 67.3% being aware of the Osun State smoke-free law although none of them had ever seen a copy of the law. A high proportion (60.0% was in support of the Osun smoke-free law although all of them think that the implementation of the law could reduce patronage and jeopardize their income. Attitude toward second-hand smoking was generally positive with 72.0% of them having no tolerance for second-hand tobacco smoke in their homes. Most participants (95.5% had been exposed to tobacco smoke in the workplace within the past week. Conclusion Despite the high level of awareness of the respondents about the dangers of second hand smoke and their positive attitude to smoke-free laws, nearly all were constantly being exposed to second hand smoke at work. This calls for policy level interventions to improve the implementation of

  9. Glycemic Control, Hand Activity, and Complexity of Biological Signals in Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Hsien-Tsai Wu

    2017-01-01

    Full Text Available Both glycemic control and handgrip strength affect microvascular function. Multiscale entropy (MSE of photoplethysmographic (PPG pulse amplitudes may differ by diabetes status and hand activity. Of a middle-to-old aged and right-handed cohort without clinical cardiovascular disease, we controlled age, sex, and weight to select the unaffected (no type 2 diabetes, n=36, the well-controlled diabetes (HbA1c < 8%, n=22, and the poorly controlled diabetes (HbA1c ≥ 8%, n=22 groups. MSEs were calculated from consecutive 1,500 PPG pulse amplitudes of bilateral index fingertips. The small-,  medium-, and large-scale MSEs were defined as the average of scale 1 (MSE1, scales 2–4 (MSE2–4, and scales 5–10 (MSE5–10, respectively. Intra- and intergroups were compared by one- and two-sample t-tests, respectively. The dominant hand MSE5–10 was lower in the poorly controlled diabetes group than the well-controlled diabetes and the unaffected (1.28 versus 1.52 and 1.56, p=0.019 and 0.001, resp. groups, whereas the nondominant hand MSE5–10 was lower in the well- and poorly controlled diabetes groups than the unaffected group (1.35 and 1.29 versus 1.58, p=0.008 and 0.005, resp.. The MSE1 of dominant hand was higher than that of nondominant hand in the well-controlled diabetes (1.35 versus 1.10, p=0.048. In conclusion, diabetes status and hand dominance may affect the MSE of PPG pulse amplitudes.

  10. A Prospective Controlled Trial of an Electronic Hand Hygiene Reminder System.

    Science.gov (United States)

    Ellison, Richard T; Barysauskas, Constance M; Rundensteiner, Elke A; Wang, Di; Barton, Bruce

    2015-12-01

    Background.  The use of electronic hand hygiene reminder systems has been proposed as an approach to improve hand hygiene compliance among healthcare workers, although information on efficacy is limited. We prospectively assessed whether hand hygiene activities among healthcare workers could be increased using an electronic hand hygiene monitoring and reminder system. Methods.  A prospective controlled clinical trial was conducted in 2 medical intensive care units (ICUs) at an academic medical center with comparable patient populations, healthcare staff, and physical layout. Hand hygiene activity was monitored concurrently in both ICUs, and the reminder system was installed in the test ICU. The reminder system was tested during 3 administered phases including: room entry/exit chimes, display of real-time hand hygiene activity, and a combination of the 2. Results.  In the test ICU, the mean number of hand hygiene events increased from 1538 per day at baseline to 1911 per day (24% increase) with the use of a combination of room entry/exit chimes, real-time displays of hand hygiene activity, and manager reports (P performance returned to baseline (1473 hand hygiene events per day) during the follow-up phase. There was no significant change in hand hygiene activity in the control ICU during the course of the trial. Conclusions.  In an ICU setting, an electronic hand hygiene reminder system that provided real-time feedback on overall unit-wide hand hygiene performance significantly increased hand hygiene activity.

  11. An Analysis of Intrinsic and Extrinsic Hand Muscle EMG for Improved Pattern Recognition Control.

    Science.gov (United States)

    Adewuyi, Adenike A; Hargrove, Levi J; Kuiken, Todd A

    2016-04-01

    Pattern recognition control combined with surface electromyography (EMG) from the extrinsic hand muscles has shown great promise for control of multiple prosthetic functions for transradial amputees. There is, however, a need to adapt this control method when implemented for partial-hand amputees, who possess both a functional wrist and information-rich residual intrinsic hand muscles. We demonstrate that combining EMG data from both intrinsic and extrinsic hand muscles to classify hand grasps and finger motions allows up to 19 classes of hand grasps and individual finger motions to be decoded, with an accuracy of 96% for non-amputees and 85% for partial-hand amputees. We evaluated real-time pattern recognition control of three hand motions in seven different wrist positions. We found that a system trained with both intrinsic and extrinsic muscle EMG data, collected while statically and dynamically varying wrist position increased completion rates from 73% to 96% for partial-hand amputees and from 88% to 100% for non-amputees when compared to a system trained with only extrinsic muscle EMG data collected in a neutral wrist position. Our study shows that incorporating intrinsic muscle EMG data and wrist motion can significantly improve the robustness of pattern recognition control for application to partial-hand prosthetic control.

  12. A Prospective Controlled Trial of an Electronic Hand Hygiene Reminder System

    Science.gov (United States)

    Ellison, Richard T.; Barysauskas, Constance M.; Rundensteiner, Elke A.; Wang, Di; Barton, Bruce

    2015-01-01

    Background. The use of electronic hand hygiene reminder systems has been proposed as an approach to improve hand hygiene compliance among healthcare workers, although information on efficacy is limited. We prospectively assessed whether hand hygiene activities among healthcare workers could be increased using an electronic hand hygiene monitoring and reminder system. Methods. A prospective controlled clinical trial was conducted in 2 medical intensive care units (ICUs) at an academic medical center with comparable patient populations, healthcare staff, and physical layout. Hand hygiene activity was monitored concurrently in both ICUs, and the reminder system was installed in the test ICU. The reminder system was tested during 3 administered phases including: room entry/exit chimes, display of real-time hand hygiene activity, and a combination of the 2. Results. In the test ICU, the mean number of hand hygiene events increased from 1538 per day at baseline to 1911 per day (24% increase) with the use of a combination of room entry/exit chimes, real-time displays of hand hygiene activity, and manager reports (P hand hygiene to room entry/exit events also increased from 26.1% to 36.6% (40% increase, P hand hygiene events per day) during the follow-up phase. There was no significant change in hand hygiene activity in the control ICU during the course of the trial. Conclusions. In an ICU setting, an electronic hand hygiene reminder system that provided real-time feedback on overall unit-wide hand hygiene performance significantly increased hand hygiene activity. PMID:26430698

  13. Does intraoperative navigation improve the accuracy of mandibular angle osteotomy: Comparison between augmented reality navigation, individualised templates and free-hand techniques.

    Science.gov (United States)

    Zhu, Ming; Liu, Fei; Zhou, Chaozheng; Lin, Li; Zhang, Yan; Chai, Gang; Xie, Le; Qi, Fazhi; Li, Qingfeng

    2018-04-11

    Augmented reality (AR)-based navigation surgery has evolved to be an advanced assisted technology. The aim of this study is to manifest the accuracy of AR navigation for the intraoperative mandibular angle osteotomy by comparing the navigation with other interventional techniques. A retrospective study was conducted with 93 post-surgical patients with mandibular angle hypertrophy admitted at our plastic and reconstructive surgery department between September 2011 and June 2016. Thirty-one patients received osteotomy conducted using a navigation system based on augmented reality (AR group), 28 patients received osteotomy conducted using individualised templates (IT group) and the remaining 34 patients received osteotomy performed by free hand (free-hand group). The post-operative computed tomography (CT) images were reviewed and analysed by comparing with pre-surgical planning generated by three-dimensional (3D) software. The preparation time, cutting time, whole operating time and discrepancy in osteotomy lines were measured. The preparation time was much shorter for the free-hand group than that for the AR group and the IT group (P  0.05). In addition, the discrepancy in osteotomy lines was lower for the AR group and in the IT group than for the free-hand group (P < 0.01). The navigation system based on AR has a higher accuracy, more reliability and better user friendliness for some particular clinical procedures than for other techniques, which has a promising clinical prospect. Copyright © 2018. Published by Elsevier Ltd.

  14. Grasp force sensor for robotic hands

    Science.gov (United States)

    Scheinman, Victor D. (Inventor); Bejczy, Antal K. (Inventor); Primus, Howard C. (Inventor)

    1989-01-01

    A grasp force sensor for robotic hands is disclosed. A flexible block is located in the base of each claw through which the grasp force is exerted. The block yields minute parallelogram deflection when the claws are subjected to grasping forces. A parallelogram deflection closely resembles pure translational deflection, whereby the claws remain in substantial alignment with each other during grasping. Strain gauge transducers supply signals which provide precise knowledge of and control over grasp forces.

  15. Real-Time Control of an Exoskeleton Hand Robot with Myoelectric Pattern Recognition.

    Science.gov (United States)

    Lu, Zhiyuan; Chen, Xiang; Zhang, Xu; Tong, Kay-Yu; Zhou, Ping

    2017-08-01

    Robot-assisted training provides an effective approach to neurological injury rehabilitation. To meet the challenge of hand rehabilitation after neurological injuries, this study presents an advanced myoelectric pattern recognition scheme for real-time intention-driven control of a hand exoskeleton. The developed scheme detects and recognizes user's intention of six different hand motions using four channels of surface electromyography (EMG) signals acquired from the forearm and hand muscles, and then drives the exoskeleton to assist the user accomplish the intended motion. The system was tested with eight neurologically intact subjects and two individuals with spinal cord injury (SCI). The overall control accuracy was [Formula: see text] for the neurologically intact subjects and [Formula: see text] for the SCI subjects. The total lag of the system was approximately 250[Formula: see text]ms including data acquisition, transmission and processing. One SCI subject also participated in training sessions in his second and third visits. Both the control accuracy and efficiency tended to improve. These results show great potential for applying the advanced myoelectric pattern recognition control of the wearable robotic hand system toward improving hand function after neurological injuries.

  16. Computer-Assisted Culture Learning in an Online Augmented Reality Environment Based on Free-Hand Gesture Interaction

    Science.gov (United States)

    Yang, Mau-Tsuen; Liao, Wan-Che

    2014-01-01

    The physical-virtual immersion and real-time interaction play an essential role in cultural and language learning. Augmented reality (AR) technology can be used to seamlessly merge virtual objects with real-world images to realize immersions. Additionally, computer vision (CV) technology can recognize free-hand gestures from live images to enable…

  17. Chirp-free direct modulation of 550 nm emission in Er3+ -Doped Fluoroindate glass by nonlinear feedback control

    Science.gov (United States)

    Cai, Runyu; Thitsa, Makhin; Bluiett, Althea; Brown, Ei; Hommerich, Uwe

    2017-06-01

    We propose a direct modulation method with nonlinear feedback controller which can produce chirp-free modulation of the output pulse without bulky external modulators. This work reports the design of the controller which, via a feedback loop, varies and controls the pump rate in real time by automatically adjusting the pump power to precisely modulate the emission of 550 nm in Er3+ -doped Fluoroindate glass under 1.48 μm pumping. In this interdisciplinary paper, well established theoretical tools from nonlinear control theory are applied to the dynamical system of the laser material in order to produce the desired output of the laser. The controller is simulated in MATLAB Simulink and the simulation results show that our technique yields precise modulation of the output intensity without frequency chirping. Results on both theoretical analysis of the control methodology and simulation are presented.

  18. Training manual for precision hand deburring, Part 2

    Energy Technology Data Exchange (ETDEWEB)

    Gillespie, L.K.

    1980-12-01

    Part 2 is presented of a 4-part training manual to be used by machinist trainees, production workers, and others removing burrs from precision miniature parts. The manuals are written to be self-teaching and are intended to be used with two hours of training each day along with another six hours of bench work in deburring.

  19. Data logging of body temperatures provides precise information on phenology of reproductive events in a free-living arctic hibernator

    Science.gov (United States)

    Williams, C.T.; Sheriff, M.J.; Schmutz, J.A.; Kohl, F.; Toien, O.; Buck, C.L.; Barnes, B.M.

    2011-01-01

    Precise measures of phenology are critical to understanding how animals organize their annual cycles and how individuals and populations respond to climate-induced changes in physical and ecological stressors. We show that patterns of core body temperature (T b) can be used to precisely determine the timing of key seasonal events including hibernation, mating and parturition, and immergence and emergence from the hibernacula in free-living arctic ground squirrels (Urocitellus parryii). Using temperature loggers that recorded T b every 20 min for up to 18 months, we monitored core T b from three females that subsequently gave birth in captivity and from 66 female and 57 male ground squirrels free-living in the northern foothills of the Brooks Range Alaska. In addition, dates of emergence from hibernation were visually confirmed for four free-living male squirrels. Average T b in captive females decreased by 0.5–1.0°C during gestation and abruptly increased by 1–1.5°C on the day of parturition. In free-living females, similar shifts in T b were observed in 78% (n = 9) of yearlings and 94% (n = 31) of adults; females without the shift are assumed not to have given birth. Three of four ground squirrels for which dates of emergence from hibernation were visually confirmed did not exhibit obvious diurnal rhythms in T b until they first emerged onto the surface when T b patterns became diurnal. In free-living males undergoing reproductive maturation, this pre-emergence euthermic interval averaged 20.4 days (n = 56). T b-loggers represent a cost-effective and logistically feasible method to precisely investigate the phenology of reproduction and hibernation in ground squirrels.

  20. End-point impedance measurements across dominant and nondominant hands and robotic assistance with directional damping.

    Science.gov (United States)

    Erden, Mustafa Suphi; Billard, Aude

    2015-06-01

    The goal of this paper is to perform end-point impedance measurements across dominant and nondominant hands while doing airbrush painting and to use the results for developing a robotic assistance scheme. We study airbrush painting because it resembles in many ways manual welding, a standard industrial task. The experiments are performed with the 7 degrees of freedom KUKA lightweight robot arm. The robot is controlled in admittance using a force sensor attached at the end-point, so as to act as a free-mass and be passively guided by the human. For impedance measurements, a set of nine subjects perform 12 repetitions of airbrush painting, drawing a straight-line on a cartoon horizontally placed on a table, while passively moving the airbrush mounted on the robot's end-point. We measure hand impedance during the painting task by generating sudden and brief external forces with the robot. The results show that on average the dominant hand displays larger impedance than the nondominant in the directions perpendicular to the painting line. We find the most significant difference in the damping values in these directions. Based on this observation, we develop a "directional damping" scheme for robotic assistance and conduct a pilot study with 12 subjects to contrast airbrush painting with and without robotic assistance. Results show significant improvement in precision with both dominant and nondominant hands when using robotic assistance.

  1. An Approach for Pattern Recognition of EEG Applied in Prosthetic Hand Drive

    Directory of Open Access Journals (Sweden)

    Xiao-Dong Zhang

    2011-12-01

    Full Text Available For controlling the prosthetic hand by only electroencephalogram (EEG, it has become the hot spot in robotics research to set up a direct communication and control channel between human brain and prosthetic hand. In this paper, the EEG signal is analyzed based on multi-complicated hand activities. And then, two methods of EEG pattern recognition are investigated, a neural prosthesis hand system driven by BCI is set up, which can complete four kinds of actions (arm’s free state, arm movement, hand crawl, hand open. Through several times of off-line and on-line experiments, the result shows that the neural prosthesis hand system driven by BCI is reasonable and feasible, the C-support vector classifiers-based method is better than BP neural network on the EEG pattern recognition for multi-complicated hand activities.

  2. Design of high precision temperature control system for TO packaged LD

    Science.gov (United States)

    Liang, Enji; Luo, Baoke; Zhuang, Bin; He, Zhengquan

    2017-10-01

    Temperature is an important factor affecting the performance of TO package LD. In order to ensure the safe and stable operation of LD, a temperature control circuit for LD based on PID technology is designed. The MAX1978 and an external PID circuit are used to form a control circuit that drives the thermoelectric cooler (TEC) to achieve control of temperature and the external load can be changed. The system circuit has low power consumption, high integration and high precision,and the circuit can achieve precise control of the LD temperature. Experiment results show that the circuit can achieve effective and stable control of the laser temperature.

  3. Virtual Control of Prosthetic Hand Based on Grasping Patterns and Estimated Force from Semg

    Directory of Open Access Journals (Sweden)

    Zhu Gao-Ke

    2016-01-01

    Full Text Available Myoelectric prosthetic hands aim to serve upper limb amputees. The myoelectric control of the hand grasp action is a kind of real-time or online method. Thus it is of great necessity to carry on a study of online prosthetic hand electrical control. In this paper, the strategy of simultaneous EMG decoding of grasping patterns and grasping force was realized by controlling a virtual multi-degree-freedom prosthetic hand and a real one-degree-freedom prosthetic hand simultaneously. The former realized the grasping patterns from the recognition of the sEMG pattern. The other implemented the grasping force from sEMG force decoding. The results show that the control method is effective and feasible.

  4. A Two-Sensor Noise Reduction System: Applications for Hands-Free Car Kit

    Directory of Open Access Journals (Sweden)

    Guérin Alexandre

    2003-01-01

    Full Text Available This paper presents a two-microphone speech enhancer designed to remove noise in hands-free car kits. The algorithm, based on the magnitude squared coherence, uses speech correlation and noise decorrelation to separate speech from noise. The remaining correlated noise is reduced using cross-spectral subtraction. Particular attention is focused on the estimation of the different spectral densities (noise and noisy signals power spectral densities which are critical for the quality of the algorithm. We also propose a continuous noise estimation, avoiding the need of vocal activity detector. Results on recorded signals are provided, showing the superiority of the two-sensor approach to single microphone techniques.

  5. Precise Control of Quantum Confinement in Cesium Lead Halide Perovskite Quantum Dots via Thermodynamic Equilibrium.

    Science.gov (United States)

    Dong, Yitong; Qiao, Tian; Kim, Doyun; Parobek, David; Rossi, Daniel; Son, Dong Hee

    2018-05-09

    Cesium lead halide (CsPbX 3 ) nanocrystals have emerged as a new family of materials that can outperform the existing semiconductor nanocrystals due to their superb optical and charge-transport properties. However, the lack of a robust method for producing quantum dots with controlled size and high ensemble uniformity has been one of the major obstacles in exploring the useful properties of excitons in zero-dimensional nanostructures of CsPbX 3 . Here, we report a new synthesis approach that enables the precise control of the size based on the equilibrium rather than kinetics, producing CsPbX 3 quantum dots nearly free of heterogeneous broadening in their exciton luminescence. The high level of size control and ensemble uniformity achieved here will open the door to harnessing the benefits of excitons in CsPbX 3 quantum dots for photonic and energy-harvesting applications.

  6. A Biomechanical Model for the Development of Myoelectric Hand Prosthesis Control Systems

    NARCIS (Netherlands)

    Peerdeman, B.; van Baal, D.W.; Boere, Daphne; Kallenberg, L.A.C.; Stramigioli, Stefano; Misra, Sarthak

    2010-01-01

    Advanced myoelectric hand prostheses aim to reproduce as much of the human hand's functionality as possible. Development of the control system of such a prosthesis is strongly connected to its mechanical design; the control system requires accurate information on the prosthesis' structure and the

  7. Design and control of five fingered under-actuated robotic hand

    Science.gov (United States)

    Sahoo, Biswojit; Parida, Pramod Kumar

    2018-04-01

    Now a day's research regarding humanoid robots and its application in different fields (industry, household, rehabilitation and exploratory) is going on entire the globe. Among which a challenging topic is to design a dexterous robotic hand which not only can perform as a hand of a robot but also can be used in re habilitation. The basic key concern is a dexterous robot hand which can be able to mimic the function of biological hand to perform different operations. This thesis work is regarding design and control of a under-actuated robotic hand consisting of four under actuated fingers (index finger, middle finger, little finger and ring finger ) , a thumb and a dexterous palm which can copy the motions and grasp type of human hand which having 21degrees of freedom instead of 25Degree Of Freedom.

  8. Distributed Control Architectures for Precision Spacecraft Formations, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — LaunchPoint Technologies, Inc. (LaunchPoint) proposes to develop synthesis methods and design architectures for distributed control systems in precision spacecraft...

  9. Precision electronic speed controller for an alternating-current motor

    Science.gov (United States)

    Bolie, V.W.

    A high precision controller for an alternating-current multi-phase electrical motor that is subject to a large inertial load. The controller was developed for controlling, in a neutron chopper system, a heavy spinning rotor that must be rotated in phase-locked synchronism with a reference pulse train that is representative of an ac power supply signal having a meandering line frequency. The controller includes a shaft revolution sensor which provides a feedback pulse train representative of the actual speed of the motor. An internal digital timing signal generator provides a reference signal which is compared with the feedback signal in a computing unit to provide a motor control signal. The motor control signal is a weighted linear sum of a speed error voltage, a phase error voltage, and a drift error voltage, each of which is computed anew with each revolution of the motor shaft. The speed error signal is generated by a novel vernier-logic circuit which is drift-free and highly sensitive to small speed changes. The phase error is also computed by digital logic, with adjustable sensitivity around a 0 mid-scale value. The drift error signal, generated by long-term counting of the phase error, is used to compensate for any slow changes in the average friction drag on the motor. An auxillary drift-byte status sensor prevents any disruptive overflow or underflow of the drift-error counter. An adjustable clocked-delay unit is inserted between the controller and the source of the reference pulse train to permit phase alignment of the rotor to any desired offset angle. The stator windings of the motor are driven by two amplifiers which are provided with input signals having the proper quadrature relationship by an exciter unit consisting of a voltage controlled oscillator, a binary counter, a pair of read-only memories, and a pair of digital-to-analog converters.

  10. Finger functionality and joystick design for complex hand control

    NARCIS (Netherlands)

    Grinten, M.P. van der; Krause, F.

    2006-01-01

    Joysticks and similar multi-directional controls are increasingly applied in machines, instruments and consumer goods. Operational complexity rises through miniaturization and additional control functions on the joystick. With this the effort for the finger, hand and arm, and for the perceptive and

  11. Free Will and Education

    Science.gov (United States)

    Giesinger, Johannes

    2010-01-01

    It is commonly assumed that to educate means to control or guide a person's acting and development. On the other hand, it is often presupposed that the addressees of education must be seen as being endowed with free will. The question raised in this paper is whether these two assumptions are compatible. It might seem that if the learner is free in…

  12. The Mirrored Hand Illusion: I Control, So I Possess?

    Science.gov (United States)

    Zhou, Aibao; Zhang, Yanchi; Yin, Yulong; Yang, Yang

    2015-01-01

    Certain situations may not only cause people to misjudge external information but also distort people's perception of themselves. The present study is the first to report the mirrored hand illusion which could be generated when the experimenter imitated the fist-clenching movements of the subject synchronously. The subjects formed the illusion that the experimenter's hand was "something I can control" when being imitated synchronously. In addition, a sense of ownership over the alien hand was established by integrating multisensory signals and comparing these signals with preexisting body presentations. This method might represent a new avenue for research on the formation of self-consciousness. © The Author(s) 2015.

  13. Hands-free image capture, data tagging and transfer using Google Glass: a pilot study for improved wound care management.

    Directory of Open Access Journals (Sweden)

    Gabriel Aldaz

    Full Text Available Chronic wounds, including pressure ulcers, compromise the health of 6.5 million Americans and pose an annual estimated burden of $25 billion to the U.S. health care system. When treating chronic wounds, clinicians must use meticulous documentation to determine wound severity and to monitor healing progress over time. Yet, current wound documentation practices using digital photography are often cumbersome and labor intensive. The process of transferring photos into Electronic Medical Records (EMRs requires many steps and can take several days. Newer smartphone and tablet-based solutions, such as Epic Haiku, have reduced EMR upload time. However, issues still exist involving patient positioning, image-capture technique, and patient identification. In this paper, we present the development and assessment of the SnapCap System for chronic wound photography. Through leveraging the sensor capabilities of Google Glass, SnapCap enables hands-free digital image capture, and the tagging and transfer of images to a patient's EMR. In a pilot study with wound care nurses at Stanford Hospital (n=16, we (i examined feature preferences for hands-free digital image capture and documentation, and (ii compared SnapCap to the state of the art in digital wound care photography, the Epic Haiku application. We used the Wilcoxon Signed-ranks test to evaluate differences in mean ranks between preference options. Preferred hands-free navigation features include barcode scanning for patient identification, Z(15 = -3.873, p < 0.001, r = 0.71, and double-blinking to take photographs, Z(13 = -3.606, p < 0.001, r = 0.71. In the comparison between SnapCap and Epic Haiku, the SnapCap System was preferred for sterile image-capture technique, Z(16 = -3.873, p < 0.001, r = 0.68. Responses were divided with respect to image quality and overall ease of use. The study's results have contributed to the future implementation of new features aimed at enhancing mobile hands-free digital

  14. Hands-Free Image Capture, Data Tagging and Transfer Using Google Glass: A Pilot Study for Improved Wound Care Management

    Science.gov (United States)

    Aldaz, Gabriel; Shluzas, Lauren Aquino; Pickham, David; Eris, Ozgur; Sadler, Joel; Joshi, Shantanu; Leifer, Larry

    2015-01-01

    Chronic wounds, including pressure ulcers, compromise the health of 6.5 million Americans and pose an annual estimated burden of $25 billion to the U.S. health care system. When treating chronic wounds, clinicians must use meticulous documentation to determine wound severity and to monitor healing progress over time. Yet, current wound documentation practices using digital photography are often cumbersome and labor intensive. The process of transferring photos into Electronic Medical Records (EMRs) requires many steps and can take several days. Newer smartphone and tablet-based solutions, such as Epic Haiku, have reduced EMR upload time. However, issues still exist involving patient positioning, image-capture technique, and patient identification. In this paper, we present the development and assessment of the SnapCap System for chronic wound photography. Through leveraging the sensor capabilities of Google Glass, SnapCap enables hands-free digital image capture, and the tagging and transfer of images to a patient’s EMR. In a pilot study with wound care nurses at Stanford Hospital (n=16), we (i) examined feature preferences for hands-free digital image capture and documentation, and (ii) compared SnapCap to the state of the art in digital wound care photography, the Epic Haiku application. We used the Wilcoxon Signed-ranks test to evaluate differences in mean ranks between preference options. Preferred hands-free navigation features include barcode scanning for patient identification, Z(15) = -3.873, p < 0.001, r = 0.71, and double-blinking to take photographs, Z(13) = -3.606, p < 0.001, r = 0.71. In the comparison between SnapCap and Epic Haiku, the SnapCap System was preferred for sterile image-capture technique, Z(16) = -3.873, p < 0.001, r = 0.68. Responses were divided with respect to image quality and overall ease of use. The study’s results have contributed to the future implementation of new features aimed at enhancing mobile hands-free digital

  15. The Human Octopus: controlling supernumerary hands with the help of virtual reality

    OpenAIRE

    Aru, Jaan; Vasser, Madis; Zafra, Raul; Kulu, Sander

    2016-01-01

    We investigated the "human octopus" phenomenon where subjects controlled virtual supernumerary hands through hand tracking technology and virtual reality. Four experiments were developed to study how subjects (n=10) operate with different number and behaviour of supernumerary hands. The behaviours involved inserting movement delays to the virtual hands and adjusting their movement scale or position. It was found that having more hands to operate with does not necessarily mean higher success r...

  16. An intelligent control scheme for precise tip-motion control in atomic force microscopy.

    Science.gov (United States)

    Wang, Yanyan; Hu, Xiaodong; Xu, Linyan

    2016-01-01

    The paper proposes a new intelligent control method to precisely control the tip motion of the atomic force microscopy (AFM). The tip moves up and down at a high rate along the z direction during scanning, requiring the utilization of a rapid feedback controller. The standard proportional-integral (PI) feedback controller is commonly used in commercial AFMs to enable topography measurements. The controller's response performance is determined by the set of the proportional (P) parameter and the integral (I) parameter. However, the two parameters cannot be automatically altered simultaneously according to the scanning speed and the surface topography during continuors scanning, leading to an inaccurate measurement. Thus a new intelligent controller combining the fuzzy controller and the PI controller is put forward in the paper. The new controller automatically selects the most appropriate PI parameters to achieve a fast response rate on basis of the tracking errors. In the experimental setup, the new controller is realized with a digital signal process (DSP) system, implemented in a conventional AFM system. Experiments are carried out by comparing the new method with the standard PI controller. The results demonstrate that the new method is more robust and effective for the precise tip motion control, corresponding to the achievement of a highly qualified image by shortening the response time of the controller. © Wiley Periodicals, Inc.

  17. Control model for dampening hand vibrations using information of internal and external coordinates.

    Directory of Open Access Journals (Sweden)

    Shunta Togo

    Full Text Available In the present study, we investigate a control mechanism that dampens hand vibrations. Here, we propose a control method with two components to suppress hand vibrations. The first is a passive suppression method that lowers the joint stiffness to passively dampen the hand vibrations. The second is an active suppression method that adjusts an equilibrium point based on skyhook control to actively dampen the hand vibrations. In a simulation experiment, we applied these two methods to dampen hand vibrations during the shoulder's horizontal oscillation. We also conducted a measurement experiment wherein a subject's shoulder was sinusoidally oscillated by a platform that generated horizontal oscillations. The results of the measurement experiments showed that the jerk of each part of the arm in a task using a cup filled with water was smaller than the shoulder jerk and that in a task with a cup filled with stones was larger than the shoulder jerk. Moreover, the amplitude of the hand trajectory in both horizontal and vertical directions was smaller in a task using a cup filled with water than in a task using a cup filled with stones. The results of the measurement experiments were accurately reproduced by the active suppression method based on skyhook control. These results suggest that humans dampen hand vibrations by controlling the equilibrium point through the information of the external workspace and the internal body state rather than by lowering joint stiffness only by using internal information.

  18. Accuracy of Plantar Electrodes Compared with Hand and Foot Electrodes in Fat-free-mass Measurement

    Directory of Open Access Journals (Sweden)

    Michel Y. Jaffrin

    2014-01-01

    Full Text Available This paper investigates the measurement of fat-free mass (FFM by bioimpedance using foot-to-foot impedancemeters (FFI with plantar electrodes measuring the foot-to-foot resistance R34 and hand-to-foot medical impedancemeters. FFM measurements were compared with corresponding data using Dual X-ray absorptiometry (DXA. Equations giving FFM were established using linear multiple regression on DXA data in a first group of 170 subjects. For validation, these equations were used on a second group of 86 subjects, and FFM were compared with DXA data; no significant difference was observed. The same protocol was repeated, but using electrodes on the right hand and foot in standing position to measure the hand to-foot resistance R13. Mean differences with DXA were higher for R13 than for R34. Effect of electrode size and feet position on resistance was also investigated. R34 decreased when electrode area increased or if feet were moved forward. It decreased if feet were moved backward. A proper configuration of contact electrodes can improve measurement accuracy and reproducibility of FFI.

  19. A new approach of active compliance control via fuzzy logic control for multifingered robot hand

    Science.gov (United States)

    Jamil, M. F. A.; Jalani, J.; Ahmad, A.

    2016-07-01

    Safety is a vital issue in Human-Robot Interaction (HRI). In order to guarantee safety in HRI, a model reference impedance control can be a very useful approach introducing a compliant control. In particular, this paper establishes a fuzzy logic compliance control (i.e. active compliance control) to reduce impact and forces during physical interaction between humans/objects and robots. Exploiting a virtual mass-spring-damper system allows us to determine a desired compliant level by understanding the behavior of the model reference impedance control. The performance of fuzzy logic compliant control is tested in simulation for a robotic hand known as the RED Hand. The results show that the fuzzy logic is a feasible control approach, particularly to control position and to provide compliant control. In addition, the fuzzy logic control allows us to simplify the controller design process (i.e. avoid complex computation) when dealing with nonlinearities and uncertainties.

  20. Real-time myoelectric control of a multi-fingered hand prosthesis using principal components analysis

    Directory of Open Access Journals (Sweden)

    Matrone Giulia C

    2012-06-01

    Full Text Available Abstract Background In spite of the advances made in the design of dexterous anthropomorphic hand prostheses, these sophisticated devices still lack adequate control interfaces which could allow amputees to operate them in an intuitive and close-to-natural way. In this study, an anthropomorphic five-fingered robotic hand, actuated by six motors, was used as a prosthetic hand emulator to assess the feasibility of a control approach based on Principal Components Analysis (PCA, specifically conceived to address this problem. Since it was demonstrated elsewhere that the first two principal components (PCs can describe the whole hand configuration space sufficiently well, the controller here employed reverted the PCA algorithm and allowed to drive a multi-DoF hand by combining a two-differential channels EMG input with these two PCs. Hence, the novelty of this approach stood in the PCA application for solving the challenging problem of best mapping the EMG inputs into the degrees of freedom (DoFs of the prosthesis. Methods A clinically viable two DoFs myoelectric controller, exploiting two differential channels, was developed and twelve able-bodied participants, divided in two groups, volunteered to control the hand in simple grasp trials, using forearm myoelectric signals. Task completion rates and times were measured. The first objective (assessed through one group of subjects was to understand the effectiveness of the approach; i.e., whether it is possible to drive the hand in real-time, with reasonable performance, in different grasps, also taking advantage of the direct visual feedback of the moving hand. The second objective (assessed through a different group was to investigate the intuitiveness, and therefore to assess statistical differences in the performance throughout three consecutive days. Results Subjects performed several grasp, transport and release trials with differently shaped objects, by operating the hand with the myoelectric

  1. A mechatronics platform to study prosthetic hand control using EMG signals.

    Science.gov (United States)

    Geethanjali, P

    2016-09-01

    In this paper, a low-cost mechatronics platform for the design and development of robotic hands as well as a surface electromyogram (EMG) pattern recognition system is proposed. This paper also explores various EMG classification techniques using a low-cost electronics system in prosthetic hand applications. The proposed platform involves the development of a four channel EMG signal acquisition system; pattern recognition of acquired EMG signals; and development of a digital controller for a robotic hand. Four-channel surface EMG signals, acquired from ten healthy subjects for six different movements of the hand, were used to analyse pattern recognition in prosthetic hand control. Various time domain features were extracted and grouped into five ensembles to compare the influence of features in feature-selective classifiers (SLR) with widely considered non-feature-selective classifiers, such as neural networks (NN), linear discriminant analysis (LDA) and support vector machines (SVM) applied with different kernels. The results divulged that the average classification accuracy of the SVM, with a linear kernel function, outperforms other classifiers with feature ensembles, Hudgin's feature set and auto regression (AR) coefficients. However, the slight improvement in classification accuracy of SVM incurs more processing time and memory space in the low-level controller. The Kruskal-Wallis (KW) test also shows that there is no significant difference in the classification performance of SLR with Hudgin's feature set to that of SVM with Hudgin's features along with AR coefficients. In addition, the KW test shows that SLR was found to be better in respect to computation time and memory space, which is vital in a low-level controller. Similar to SVM, with a linear kernel function, other non-feature selective LDA and NN classifiers also show a slight improvement in performance using twice the features but with the drawback of increased memory space requirement and time

  2. Precise measurement of magnetic field gradients from free spin precession signals of He-3 and Xe-129 magnetometers

    NARCIS (Netherlands)

    Allmendinger, Fabian; Blümler, Peter; Doll, Michael; Grasdijk, Oliver; Heil, Werner; Jungmann, Klaus; Karpuk, Sergej; Krause, Hans-Joachim; Offenhäuser, Andreas; Repetto, Maricel; Schmidt, Ulrich; Sobolev, Yuri; Tullney, Kathlyne; Willmann, Lorenz; Zimmer, Stefan

    2017-01-01

    We report on precise measurements of magnetic field gradients extracted from transverse relaxation rates of precessing spin samples. The experimental approach is based on the free precession of gaseous, nuclear spin polarized He-3 and (12)9Xe atoms in a spherical cell inside a magnetic guiding field

  3. Human versus Robot: A Propensity-Matched Analysis of the Accuracy of Free Hand versus Robotic Guidance for Placement of S2 Alar-Iliac (S2AI) Screws.

    Science.gov (United States)

    Shillingford, Jamal N; Laratta, Joseph L; Park, Paul J; Lombardi, Joseph M; Tuchman, Alexander; Saifi, Comron S; Lehman, Ronald A; Lenke, Lawrence G

    2018-04-18

    Retrospective matched cohort analysis. To compare the accuracy of S2 alar-iliac (S2AI) screw placement by robotic guidance versus free hand technique. Spinopelvic fixation utilizing S2AI screws provides optimal fixation across the lumbosacral junction allowing for solid fusion, especially in long segment fusion constructs. Traditionally, S2AI screw placement has required fluoroscopic guidance for accurate screw placement. Herein, we present the first series comparing a free hand and robotic-guided technique for S2AI screw placement. Sixty-eight consecutive patients who underwent S2AI screw placement by either a free hand or robotic technique between 2015 and 2016 were reviewed. Propensity score-matching was utilized to control for preoperative characteristic imbalances. Screw position and accuracy were evaluated using three-dimensional manipulation of CT reconstructions from intraoperative O-arm imaging. A total of 51 patients (105 screws) were matched, 28 (59 screws) in the free hand group (FHG) and 23 (46 screws) in the robot group (RG). The mean age in the FHG and RG were 57.9[REPLACEMENT CHARACTER]± 14.6 years and 61.6[REPLACEMENT CHARACTER]± 12.0 years (P = 0.342), respectively. The average caudal angle in the sagittal plane was significantly larger in the RG (31.0[REPLACEMENT CHARACTER]± 10.0° vs. 25.7[REPLACEMENT CHARACTER]± 8.8°, P =[REPLACEMENT CHARACTER]0.005). There was no difference between the FHG and RG in the horizontal angle, measured in the axial plane using the posterior superior iliac spine (PSIS) as a reference (41.1[REPLACEMENT CHARACTER]± 8.1° vs. 42.8[REPLACEMENT CHARACTER]± 6.6°, P =[REPLACEMENT CHARACTER]0.225), or the S2AI to S1 screw angle (9.4[REPLACEMENT CHARACTER]± 7.0° vs. 11.3[REPLACEMENT CHARACTER]± 9.9°, P =[REPLACEMENT CHARACTER]0.256), respectively. There was no difference in the overall accuracy between FHG and RG (94.9% vs. 97.8%, P =[REPLACEMENT CHARACTER]0.630). Additionally, there

  4. Precision Attitude Control for the BETTII Balloon-Borne Interferometer

    Science.gov (United States)

    Benford, Dominic J.; Fixsen, Dale J.; Rinehart. Stephen

    2012-01-01

    The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII) is an 8-meter baseline far-infrared interferometer to fly on a high altitude balloon. Operating at wavelengths of 30-90 microns, BETTII will obtain spatial and spectral information on science targets at angular resolutions down to less than half an arcsecond, a capability unmatched by other far-infrared facilities. This requires attitude control at a level ofless than a tenth of an arcsecond, a great challenge for a lightweight balloon-borne system. We have designed a precision attitude determination system to provide gondola attitude knowledge at a level of 2 milliarcseconds at rates up to 100Hz, with accurate absolute attitude determination at the half arcsecond level at rates of up to 10Hz. A mUlti-stage control system involving rigid body motion and tip-tilt-piston correction provides precision pointing stability to the level required for the far-infrared instrument to perform its spatial/spectral interferometry in an open-loop control. We present key aspects of the design of the attitude determination and control and its development status.

  5. Precise Localization and Control of Catalytic Janus Micromotors Using Weak Magnetic Fields

    Directory of Open Access Journals (Sweden)

    Islam S. M. Khalil

    2015-01-01

    Full Text Available We experimentally demonstrate the precise localization of spherical Pt-Silica Janus micromotors (diameter 5 μm under the influence of controlled magnetic fields. First, we control the motion of the Janus micromotors in two-dimensional (2D space. The control system achieves precise localization within an average region-of-convergence of 7 μm. Second, we show that these micromotors provide sufficient propulsion force, allowing them to overcome drag and gravitational forces and move both downwards and upwards. This propulsion is studied by moving the micromotors in three-dimensional (3D space. The micromotors move downwards and upwards at average speeds of 19.1 μm/s and 9.8 μm/s, respectively. Moreover, our closed-loop control system achieves localization in 3D space within an average region-of-convergence of 6.3 μm in diameter. The precise motion control and localization of the Janus micromotors in 2D and 3D spaces provides broad possibilities for nanotechnology applications.

  6. Towards free 3D end-point control for robotic-assisted human reaching using binocular eye tracking.

    Science.gov (United States)

    Maimon-Dror, Roni O; Fernandez-Quesada, Jorge; Zito, Giuseppe A; Konnaris, Charalambos; Dziemian, Sabine; Faisal, A Aldo

    2017-07-01

    Eye-movements are the only directly observable behavioural signals that are highly correlated with actions at the task level, and proactive of body movements and thus reflect action intentions. Moreover, eye movements are preserved in many movement disorders leading to paralysis (or amputees) from stroke, spinal cord injury, Parkinson's disease, multiple sclerosis, and muscular dystrophy among others. Despite this benefit, eye tracking is not widely used as control interface for robotic interfaces in movement impaired patients due to poor human-robot interfaces. We demonstrate here how combining 3D gaze tracking using our GT3D binocular eye tracker with custom designed 3D head tracking system and calibration method enables continuous 3D end-point control of a robotic arm support system. The users can move their own hand to any location of the workspace by simple looking at the target and winking once. This purely eye tracking based system enables the end-user to retain free head movement and yet achieves high spatial end point accuracy in the order of 6 cm RMSE error in each dimension and standard deviation of 4 cm. 3D calibration is achieved by moving the robot along a 3 dimensional space filling Peano curve while the user is tracking it with their eyes. This results in a fully automated calibration procedure that yields several thousand calibration points versus standard approaches using a dozen points, resulting in beyond state-of-the-art 3D accuracy and precision.

  7. Use of a Proximity Sensor Switch for "Hands Free" Operation of Computer-Based Video Prompting by Young Adults with Moderate Intellectual Disability

    Science.gov (United States)

    Ivey, Alexandria N.; Mechling, Linda C.; Spencer, Galen P.

    2015-01-01

    In this study, the effectiveness of a "hands free" approach for operating video prompts to complete multi-step tasks was measured. Students advanced the video prompts by using a motion (hand wave) over a proximity sensor switch. Three young adult females with a diagnosis of moderate intellectual disability participated in the study.…

  8. Effects of age and the use of hands-free cellular phones on driving behavior and task performance.

    Science.gov (United States)

    Liu, Yung-Ching; Ou, Yang-Kun

    2011-12-01

    This study used a driving simulator to investigate the effect of using a Bluetooth hands-free cellular phone earpiece on the driving behavior of two age groups. Forty-eight participants (24 aged 20-26 and 24 aged 65-73) were examined to assess their performance on the following divided-attention tasks under 2 driving load conditions (high and low): (1) attempting to maintain the speed limit and (2) using a cellular phone while driving. The length of the call conversation (long vs. short) and the conversational content (complex vs. simple) were manipulated as within-subject independent variables. The driving behavior of the participants, their task reaction times and accuracy, and subjective ratings were collected as dependent variables. The results indicate that under low driving loads, short talk times, and simple conversational content, the driving behavior of the participants showed low variance in the vehicle's mean speed. In contrast, complex conversation had a significantly negative impact on driving behavior. Notably, under a low driving load, motorists' driving behaviors, measured in lateral acceleration, caused significantly smaller variance in complex conversations compared to no call and simple conversations. The use of a hands-free cellular phone affected the performance (acceleration, lane deviation, reaction time, and accuracy) of older drivers significantly more than younger drivers. While performing divided attention tasks, the accuracy of the older drivers was 66.3 percent and that of the younger drivers was 96.3 percent. Although this study did not find a clear impact of cellular phone use on the driving behavior of younger drivers, their divided-attention task reaction times and accuracy were better under no-call than calling conditions. This study indicates that the use of hands-free cellular phones could significantly affect the safety of driving among the older and present risks, although lesser, for younger drivers.

  9. A four-axis hand controller for helicopter flight control

    Science.gov (United States)

    Demaio, Joe

    1993-01-01

    A proof-of-concept hand controller for controlling lateral and longitudinal cyclic pitch, collective pitch and tail rotor thrust was developed. The purpose of the work was to address problems of operator fatigue, poor proprioceptive feedback and cross-coupling of axes associated with many four-axis controller designs. The present design is an attempt to reduce cross-coupling to a level that can be controlled with breakout force, rather than to eliminate it entirely. The cascaded design placed lateral and longitudinal cyclic in their normal configuration. Tail rotor thrust was placed atop the cyclic controller. A left/right twisting motion with the wrist made the control input. The axis of rotation was canted outboard (clockwise) to minimize cross-coupling with the cyclic pitch axis. The collective control was a twist grip, like a motorcycle throttle. Measurement of the amount of cross-coupling involved in pure, single-axis inputs showed cross coupling under 10 percent of full deflection for all axes. This small amount of cross-coupling could be further reduced with better damping and force gradient control. Fatigue was not found to be a problem, and proprioceptive feedback was adequate for all flight tasks executed.

  10. An Ultra-low Frequency Modal Testing Suspension System for High Precision Air Pressure Control

    Directory of Open Access Journals (Sweden)

    Qiaoling YUAN

    2014-05-01

    Full Text Available As a resolution for air pressure control challenges in ultra-low frequency modal testing suspension systems, an incremental PID control algorithm with dead band is applied to achieve high-precision pressure control. We also develop a set of independent hardware and software systems for high-precision pressure control solutions. Taking control system versatility, scalability, reliability, and other aspects into considerations, a two-level communication employing Ethernet and CAN bus, is adopted to complete such tasks as data exchange between the IPC, the main board and the control board ,and the pressure control. Furthermore, we build a single set of ultra-low frequency modal testing suspension system and complete pressure control experiments, which achieve the desired results and thus confirm that the high-precision pressure control subsystem is reasonable and reliable.

  11. Measurement of hand bone mineral content using single-photon absorptiometry

    International Nuclear Information System (INIS)

    Nicoll, J.J.; Smith, M.A.; Law, E.; Tothill, P.; Reid, D.; Brown, N.; Nuki, G.

    1987-01-01

    A single photon absorption imaging technique has been developed to assess the bone mass of the hand, especially in patients with rheumatoid arthritis or bronchial asthma. A modified rectilinear scanner images the hand by transmission scanning in a water bath with a 7.4 GBq 125 I source. A microcomputer is used to calculate the bone mineral distribution, and the total bone mineral content (BMC) of the hand is determined from that distribution. The precision (coefficient of variation) of the measurement is 1.9%. A control population of 20 men and 58 women has been studied to determine normal variations in hand bone mineral content with age, sex, body size, hand volume and years since menopause. The normal men are found to have an average hand BMC of 25.1 g with a coefficient of variation (CV) of 22%, which is reduced to 12% by normalising for body size using span. The normal women had an average hand BMC of 18.0 g +- 15%. The CV is reduced to 13% by normalising for span and years post-menopause. (author)

  12. Precision mechatronics based on high-precision measuring and positioning systems and machines

    Science.gov (United States)

    Jäger, Gerd; Manske, Eberhard; Hausotte, Tino; Mastylo, Rostyslav; Dorozhovets, Natalja; Hofmann, Norbert

    2007-06-01

    Precision mechatronics is defined in the paper as the science and engineering of a new generation of high precision systems and machines. Nanomeasuring and nanopositioning engineering represents important fields of precision mechatronics. The nanometrology is described as the today's limit of the precision engineering. The problem, how to design nanopositioning machines with uncertainties as small as possible will be discussed. The integration of several optical and tactile nanoprobes makes the 3D-nanopositioning machine suitable for various tasks, such as long range scanning probe microscopy, mask and wafer inspection, nanotribology, nanoindentation, free form surface measurement as well as measurement of microoptics, precision molds, microgears, ring gauges and small holes.

  13. Telerobotic control of a dextrous manipulator using master and six-DOF hand-controllers for space assembly and servicing tasks

    Science.gov (United States)

    O'Hara, John M.

    1987-01-01

    Two studies were conducted evaluating methods of controlling a telerobot; bilateral force reflecting master controllers and proportional rate six degrees of freedom (DOF) hand controllers. The first study compared the controllers on performance of single manipulator arm tasks, a peg-in-the-hole task, and simulated satellite orbital replacement unit changeout. The second study, a Space Station truss assembly task, required simultaneous operation of both manipulator arms (all 12 DOFs) and complex multiaxis slave arm movements. Task times were significantly longer and fewer errors were committed with the hand controllers. The hand controllers were also rated significantly higher in cognitive and manual control workload on the two-arm task. The master controllers were rated significantly higher in physical workload. There were no significant differences in ratings of manipulator control quality.

  14. Compact Dexterous Robotic Hand

    Science.gov (United States)

    Lovchik, Christopher Scott (Inventor); Diftler, Myron A. (Inventor)

    2001-01-01

    A compact robotic hand includes a palm housing, a wrist section, and a forearm section. The palm housing supports a plurality of fingers and one or more movable palm members that cooperate with the fingers to grasp and/or release an object. Each flexible finger comprises a plurality of hingedly connected segments, including a proximal segment pivotally connected to the palm housing. The proximal finger segment includes at least one groove defining first and second cam surfaces for engagement with a cable. A plurality of lead screw assemblies each carried by the palm housing are supplied with power from a flexible shaft rotated by an actuator and output linear motion to a cable move a finger. The cable is secured within a respective groove and enables each finger to move between an opened and closed position. A decoupling assembly pivotally connected to a proximal finger segment enables a cable connected thereto to control movement of an intermediate and distal finger segment independent of movement of the proximal finger segment. The dexterous robotic hand closely resembles the function of a human hand yet is light weight and capable of grasping both heavy and light objects with a high degree of precision.

  15. 3D Visual Sensing of the Human Hand for the Remote Operation of a Robotic Hand

    Directory of Open Access Journals (Sweden)

    Pablo Gil

    2014-02-01

    Full Text Available New low cost sensors and open free libraries for 3D image processing are making important advances in robot vision applications possible, such as three-dimensional object recognition, semantic mapping, navigation and localization of robots, human detection and/or gesture recognition for human-machine interaction. In this paper, a novel method for recognizing and tracking the fingers of a human hand is presented. This method is based on point clouds from range images captured by a RGBD sensor. It works in real time and it does not require visual marks, camera calibration or previous knowledge of the environment. Moreover, it works successfully even when multiple objects appear in the scene or when the ambient light is changed. Furthermore, this method was designed to develop a human interface to control domestic or industrial devices, remotely. In this paper, the method was tested by operating a robotic hand. Firstly, the human hand was recognized and the fingers were detected. Secondly, the movement of the fingers was analysed and mapped to be imitated by a robotic hand.

  16. Development of Hand Grip Assistive Device Control System for Old People through Electromyography (EMG) Signal Acquisitions

    OpenAIRE

    Khamis Herman; Mohamaddan Shahrol; Komeda Takashi; Alias Aidil Azli; Tanjong Shirley Jonathan; Julai Norhuzaimin; Hashim Nurul ‘Izzati

    2017-01-01

    The hand grip assistive device is a glove to assist old people who suffer from hand weakness in their daily life activities. The device earlier control system only use simple on and off switch. This required old people to use both hand to activate the device. The new control system of the hand grip assistive device was developed to allow single hand operation for old people. New control system take advantages of electromyography (EMG) and flex sensor which was implemented to the device. It wa...

  17. Integration of robotics and neuroscience beyond the hand: What kind of synergies?. Comment on "Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands" by Marco Santello et al.

    Science.gov (United States)

    d'Avella, Andrea

    2016-07-01

    Santello et al. [1] review an impressive amount of work on the control of biological and artificial hands that demonstrates how the concept of synergies can lead to a successful integration of robotics and neuroscience. Is it possible to generalize the same approach to the control of biological and artificial limbs and bodies beyond the hand? The human hand synergies that appear most relevant for robotic hands are those defined at the kinematic level, i.e. postural synergies [2]. Postural synergies capture the geometric relations among the many joints of the hand and allow for a low dimensional characterization and synthesis of the static hand postures involved in grasping and manipulating a large set of objects. However, many other complex motor skills such as walking, reaching, throwing, and catching require controlling multi-articular time-varying trajectories rather than static postures. Dynamic control of biological and artificial limbs and bodies, especially when geometric and inertial parameters are uncertain and the joints are compliant, poses great challenges. What kind of synergies might simplify the dynamic control of motor skills involving upper and lower limbs as well as the whole body?

  18. fMRI-compatible rehabilitation hand device

    Directory of Open Access Journals (Sweden)

    Tzika Aria

    2006-10-01

    Full Text Available Abstract Background Functional magnetic resonance imaging (fMRI has been widely used in studying human brain functions and neurorehabilitation. In order to develop complex and well-controlled fMRI paradigms, interfaces that can precisely control and measure output force and kinematics of the movements in human subjects are needed. Optimized state-of-the-art fMRI methods, combined with magnetic resonance (MR compatible robotic devices for rehabilitation, can assist therapists to quantify, monitor, and improve physical rehabilitation. To achieve this goal, robotic or mechatronic devices with actuators and sensors need to be introduced into an MR environment. The common standard mechanical parts can not be used in MR environment and MR compatibility has been a tough hurdle for device developers. Methods This paper presents the design, fabrication and preliminary testing of a novel, one degree of freedom, MR compatible, computer controlled, variable resistance hand device that may be used in brain MR imaging during hand grip rehabilitation. We named the device MR_CHIROD (Magnetic Resonance Compatible Smart Hand Interfaced Rehabilitation Device. A novel feature of the device is the use of Electro-Rheological Fluids (ERFs to achieve tunable and controllable resistive force generation. ERFs are fluids that experience dramatic changes in rheological properties, such as viscosity or yield stress, in the presence of an electric field. The device consists of four major subsystems: a an ERF based resistive element; b a gearbox; c two handles and d two sensors, one optical encoder and one force sensor, to measure the patient induced motion and force. The smart hand device is designed to resist up to 50% of the maximum level of gripping force of a human hand and be controlled in real time. Results Laboratory tests of the device indicate that it was able to meet its design objective to resist up to approximately 50% of the maximum handgrip force. The detailed

  19. Smart indoor climate control in precision livestock farming

    DEFF Research Database (Denmark)

    Zhang, Guoqiang; Bjerg, Bjarne Schmidt; Wang, Xiaoshuai

    2016-01-01

    One of the major objectives of precision livestock farming (PLF) is to provide an optimal thermal climate control in the animal occupant zones for promoting animal production and wellbeing. To achieve this goal, smart climate models that reflect the needs of different animal species and ages or f...... condition in AOZ. In addition, the paper presents a fundamental principle of development of an integrated indoor climate sensor to reflect animal thermal wellbeing and techniques that could be used for a smart system design and control are discussed....

  20. Do hospital visitors wash their hands? Assessing the use of alcohol-based hand sanitizer in a hospital lobby.

    Science.gov (United States)

    Birnbach, David J; Nevo, Igal; Barnes, Susan; Fitzpatrick, Maureen; Rosen, Lisa F; Everett-Thomas, Ruth; Sanko, Jill S; Arheart, Kristopher L

    2012-05-01

    Reports regarding hand hygiene compliance (HHC) among hospital visitors are limited. Although there is an implicit assumption that the availability of alcohol-based hand sanitizer (AHS) promotes visitor HHC, the degree of AHS use by visitors remains unclear. To assess AHS use, we observed visitor HHC and how it is affected by visual cues in a private university hospital. Using an observational controlled study, we tested 3 interventions: a desk sign mandating all visitors to use AHS, a free-standing AHS dispenser directly in front of a security desk, and a combination of a freestanding AHS dispenser and a sign. HHC was 0.52% at baseline and did not improve significantly when the desk sign was provided as a cue 0.67% (P = .753). However, HHC did improve significantly with use of the freestanding AHS dispenser (9.33%) and the sign and dispenser combination (11.67%) (P hand hygiene behavior. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  1. Does intraoperative navigation improve the accuracy of pedicle screw placement in the apical region of dystrophic scoliosis secondary to neurofibromatosis type I: comparison between O-arm navigation and free-hand technique.

    Science.gov (United States)

    Jin, Mengran; Liu, Zhen; Liu, Xingyong; Yan, Huang; Han, Xiao; Qiu, Yong; Zhu, Zezhang

    2016-06-01

    To assess the accuracy of O-arm-navigation-based pedicle screw insertion in dystrophic scoliosis secondary to NF-1 and compare it with free-hand pedicle screw insertion technique. 32 patients with dystrophic NF-1-associated scoliosis were divided into two groups. A total of 92 pedicle screws were implanted in apical region (two vertebrae above and below the apex each) in 13 patients using O-arm-based navigation (O-arm group), and 121 screws were implanted in 19 patients using free-hand technique (free-hand group). The postoperative CT images were reviewed and analyzed for pedicle violation. The screw penetration was divided into four grades: grade 0 (ideal placement), grade 1 (penetration 4 mm). The accuracy rate of pedicle screw placement (grade 0, 1) was significantly higher in the O-arm group (79 %, 73/92) compared to 67 % (81/121) of the free-hand group (P = 0.045). Meanwhile, a significantly lower prevalence of grade 2-3 perforation was observed in the O-arm group (21 vs. 33 %, P arm navigation compared to free-hand technique (2 vs. 15 %, P arm navigation (58 vs. 42 %, P arm-based pedicle screw placement in dystrophic NF-1-associated scoliosis. O-arm navigation system does facilitate pedicle screw insertion in dystrophic NF-1-associated scoliosis, demonstrating superiorities in the safety and accuracy of pedicle screw placement in comparison with free-hand technique.

  2. Deaccessioning and Agency Costs of Free Cash Flow in Manager's Hands: A Formal Model

    Directory of Open Access Journals (Sweden)

    Andrej Srakar

    2014-12-01

    Full Text Available The problem of agency costs of free cash flow in manager's hands has been firstly noted by Easterbrook and Jensen. We present one of the first attempts to formally model the problem in light of similar situation faced by managers of museums being allowed (or disallowed to deaccession the artworks from their collections. We show that deaccessioning funds always lead to various forms of agency costs for the museum. This finding applies for any non-profit firm and its endowment. The task lying ahead is to formally prove the general conjecture also for the case of private for-profit firms.

  3. Modeling and control of precision actuators

    CERN Document Server

    Kiong, Tan Kok

    2013-01-01

    IntroductionGrowing Interest in Precise ActuatorsTypes of Precise ActuatorsApplications of Precise ActuatorsNonlinear Dynamics and ModelingHysteresisCreepFrictionForce RipplesIdentification and Compensation of Preisach Hysteresis in Piezoelectric ActuatorsSVD-Based Identification and Compensation of Preisach HysteresisHigh-Bandwidth Identification and Compensation of Hysteretic Dynamics in Piezoelectric ActuatorsConcluding RemarksIdentification and Compensation of Frict

  4. Control of a Supernumerary Robotic Hand by Foot: An Experimental Study in Virtual Reality.

    Science.gov (United States)

    Abdi, Elahe; Burdet, Etienne; Bouri, Mohamed; Bleuler, Hannes

    2015-01-01

    In the operational theater, the surgical team could highly benefit from a robotic supplementary hand under the surgeon's full control. The surgeon may so become more autonomous; this may reduce communication errors with the assistants and take over difficult tasks such as holding tools without tremor. In this paper, we therefore examine the possibility to control a third robotic hand with one foot's movements. Three experiments in virtual reality were designed to assess the feasibility of this control strategy, the learning curve of the subjects in different tasks and the coordination of foot movements with the two natural hands. Results show that the limbs are moved simultaneously, in parallel rather than serially. Participants' performance improved within a few minutes of practice without any specific difficulty to complete the tasks. Subjective assessment by the subjects indicated that controlling a third hand by foot has been easy and required only negligible physical and mental efforts. The sense of ownership was reported to improve through the experiments. The mental burden was not directly related to the level of motion required by a task, but depended on the type of activity and practice. The most difficult task was moving two hands and foot in opposite directions. These results suggest that a combination of practice and appropriate tasks can enhance the learning process for controlling a robotic hand by foot.

  5. Control of a Supernumerary Robotic Hand by Foot: An Experimental Study in Virtual Reality.

    Directory of Open Access Journals (Sweden)

    Elahe Abdi

    Full Text Available In the operational theater, the surgical team could highly benefit from a robotic supplementary hand under the surgeon's full control. The surgeon may so become more autonomous; this may reduce communication errors with the assistants and take over difficult tasks such as holding tools without tremor. In this paper, we therefore examine the possibility to control a third robotic hand with one foot's movements. Three experiments in virtual reality were designed to assess the feasibility of this control strategy, the learning curve of the subjects in different tasks and the coordination of foot movements with the two natural hands. Results show that the limbs are moved simultaneously, in parallel rather than serially. Participants' performance improved within a few minutes of practice without any specific difficulty to complete the tasks. Subjective assessment by the subjects indicated that controlling a third hand by foot has been easy and required only negligible physical and mental efforts. The sense of ownership was reported to improve through the experiments. The mental burden was not directly related to the level of motion required by a task, but depended on the type of activity and practice. The most difficult task was moving two hands and foot in opposite directions. These results suggest that a combination of practice and appropriate tasks can enhance the learning process for controlling a robotic hand by foot.

  6. Integrated Quality Control of Precision Assemblies using Computed Tomography

    DEFF Research Database (Denmark)

    Stolfi, Alessandro

    coor-dinate measuring machines (CMMs) when working with complex and fragile parts. This Ph.D. project at DTU Mechanical Engineering concerns the applicability of CT for quality control of precision assem-blies. Investigations to quantify the accuracy of CT measurements, reference artefacts to correct...

  7. Electron Bunch Timing with Femtosecond Precision in a Superconducting Free-Electron Laser

    Science.gov (United States)

    Löhl, F.; Arsov, V.; Felber, M.; Hacker, K.; Jalmuzna, W.; Lorbeer, B.; Ludwig, F.; Matthiesen, K.-H.; Schlarb, H.; Schmidt, B.; Schmüser, P.; Schulz, S.; Szewinski, J.; Winter, A.; Zemella, J.

    2010-04-01

    High-gain free-electron lasers (FELs) are capable of generating femtosecond x-ray pulses with peak brilliances many orders of magnitude higher than at other existing x-ray sources. In order to fully exploit the opportunities offered by these femtosecond light pulses in time-resolved experiments, an unprecedented synchronization accuracy is required. In this Letter, we distributed the pulse train of a mode-locked fiber laser with femtosecond stability to different locations in the linear accelerator of the soft x-ray FEL FLASH. A novel electro-optic detection scheme was applied to measure the electron bunch arrival time with an as yet unrivaled precision of 6 fs (rms). With two beam-based feedback systems we succeeded in stabilizing both the arrival time and the electron bunch compression process within two magnetic chicanes, yielding a significant reduction of the FEL pulse energy jitter.

  8. Electron Bunch Timing with Femtosecond Precision in a Superconducting Free-Electron Laser

    International Nuclear Information System (INIS)

    Loehl, F.; Arsov, V.; Felber, M.; Hacker, K.; Lorbeer, B.; Ludwig, F.; Matthiesen, K.-H.; Schlarb, H.; Schmidt, B.; Winter, A.; Jalmuzna, W.; Schmueser, P.; Schulz, S.; Zemella, J.; Szewinski, J.

    2010-01-01

    High-gain free-electron lasers (FELs) are capable of generating femtosecond x-ray pulses with peak brilliances many orders of magnitude higher than at other existing x-ray sources. In order to fully exploit the opportunities offered by these femtosecond light pulses in time-resolved experiments, an unprecedented synchronization accuracy is required. In this Letter, we distributed the pulse train of a mode-locked fiber laser with femtosecond stability to different locations in the linear accelerator of the soft x-ray FEL FLASH. A novel electro-optic detection scheme was applied to measure the electron bunch arrival time with an as yet unrivaled precision of 6 fs (rms). With two beam-based feedback systems we succeeded in stabilizing both the arrival time and the electron bunch compression process within two magnetic chicanes, yielding a significant reduction of the FEL pulse energy jitter.

  9. Precision measurement of the 1S Lamb shift in atomic hydrogen

    International Nuclear Information System (INIS)

    Beausoleil, R.G.; McIntyre, D.H.; Foot, C.J.; Couillaud, B.; Hildum, E.A.; Hansch, T.W.

    1987-01-01

    The authors used cw Doppler-free two-photon spectroscopy to measure the 1S-2S transition frequency in atomic hydrogen gas with a precision of 6 parts in 10 10 . Their result for the energy level separation is f(1S-2S) = 2 466 061 413.3(1.5) MHz and can be used to extract a value of the 1S Lamb shift. Choosing a value of the Rydberg constant measured independently by high-resolution spectroscopy of the hydrogen Balmer-β transition, the authors obtain a value of Δf/sub Lamb/(1S) = 8 173.3(1.7) MHz, in good agreement with the theoretical prediction of 8 173.06(20) MHz. On the other hand, if they trust the theoretical determination of the 1S Lamb shift, they can interpret our experimental result as a measurement of the Rydberg constant. The authors obtain R∞ = 109 737.315(7) cm -1 , in agreement with recent precise measurements

  10. EFFECT OF MORPHOLOGICAL CHARACTERISTICS OF PRECISION IN BASKETBALL

    Directory of Open Access Journals (Sweden)

    Nazim Myrtaj

    2012-09-01

    Full Text Available Basketball in its structure is very complicated and complex activity in which kinesiology success depends on the influence of a large number of anthropological traits and abilities, which are interconnected. Therefore, the aim of this paper is to determine the influence of morphological characteristics as anthropological characteristics of situational-motor, or the accuracy of the basketball game. The survey was conducted in 71 male subjects aged, 15 years ± 6 months, participants school basketball team “Drita” from Gjilani, Kosovo.The sample of variables obtained on the basis of 10 anthropometric measures in the IPB, under which, among other things, three possible estimates of latent anthropometric dimensions of two tests of situational-motor skills and precision. Regression analysis was applied in order to determine the statistical significance of the impact of the entire set of predictive variables on the criterion variable and individual impact of individual predictors on the criterion variable. Analyses were made to the program SPSS 14.0. From the data obtained by regression analysis can be concluded that the better the performance of situational-motor test, or test the accuracy of dribbling in a distance of 5 meters jump shot from the free throw line (MPSŠ in the patients who had a higher level (AVIS, had longer feet (ADUNA, who had a hand longer (ADURO, greater length of the foot (ADUS, the higher the upper arm (AONL and larger volume of lower leg (AOPK. The system of prediction of morphological variables has statistically significant effect on the criterion one free throw in the bin (MPSŠ at 0.000. Morphological analysis of individual predictor variables, we can conclude that a statistically significant effect on the variable with two morphological variables: length of the hand (ADUS and width of the hand (ASSA.

  11. Visual Field Preferences of Object Analysis for Grasping with One Hand

    Directory of Open Access Journals (Sweden)

    Ada eLe

    2014-10-01

    Full Text Available When we grasp an object using one hand, the opposite hemisphere predominantly guides the motor control of grasp movements (Davare et al. 2007; Rice et al. 2007. However, it is unclear whether visual object analysis for grasp control relies more on inputs (a from the contralateral than the ipsilateral visual field, (b from one dominant visual field regardless of the grasping hand, or (c from both visual fields equally. For bimanual grasping of a single object we have recently demonstrated a visual field preference for the left visual field (Le and Niemeier 2013a, 2013b, consistent with a general right-hemisphere dominance for sensorimotor control of bimanual grasps (Le et al., 2013. But visual field differences have never been tested for unimanual grasping. Therefore, here we asked right-handed participants to fixate to the left or right of an object and then grasp the object either with their right or left hand using a precision grip. We found that participants grasping with their right hand performed better with objects in the right visual field: maximum grip apertures (MGAs were more closely matched to the object width and were smaller than for objects in the left visual field. In contrast, when people grasped with their left hand, preferences switched to the left visual field. What is more, MGA scaling showed greater visual field differences compared to right-hand grasping. Our data suggest that, visual object analysis for unimanual grasping shows a preference for visual information from the ipsilateral visual field, and that the left hemisphere is better equipped to control grasps in both visual fields.

  12. Vibration control for precision manufacturing using piezoelectric actuators

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, D.R.; Hinnerichs, T.D.; Redmond, J.M.

    1995-12-31

    Piezoelectric actuators provide high frequency, force, and stiffness capabilities along with reasonable Stroke limits, all of which can be used to increase performance levels in precision manufacturing systems. This paper describes two examples of embedding piezoelectric actuators in structural components for vibration control. One example involves suppressing the self excited chatter phenomenon in the metal cutting process of a milling machine and the other involves damping vibrations induced by rigid body stepping of a photolithography platen. Finite element modeling and analyses are essential for locating and sizing the actuators and permit further simulation studies of the response of the dynamic system. Experimental results are given for embedding piezoelectric actuators in a cantilevered bar configuration, which was used as a surrogate machine tool structure. These results are incorporated into a previously developed milling process simulation and the effect of the control on the cutting process stability diagram is quantified. Experimental results are also given for embedding three piezoelectric actuators in a surrogate photolithography platen to suppress vibrations. These results demonstrate the potential benefit that can be realized by applying advances from the field of adaptive structures to problems in precision manufacturing.

  13. Comparative study of state-of-the-art myoelectric controllers for multigrasp prosthetic hands.

    Science.gov (United States)

    Segil, Jacob L; Controzzi, Marco; Weir, Richard F ff; Cipriani, Christian

    2014-01-01

    A myoelectric controller should provide an intuitive and effective human-machine interface that deciphers user intent in real-time and is robust enough to operate in daily life. Many myoelectric control architectures have been developed, including pattern recognition systems, finite state machines, and more recently, postural control schemes. Here, we present a comparative study of two types of finite state machines and a postural control scheme using both virtual and physical assessment procedures with seven nondisabled subjects. The Southampton Hand Assessment Procedure (SHAP) was used in order to compare the effectiveness of the controllers during activities of daily living using a multigrasp artificial hand. Also, a virtual hand posture matching task was used to compare the controllers when reproducing six target postures. The performance when using the postural control scheme was significantly better (p state machines during the physical assessment when comparing within-subject averages using the SHAP percent difference metric. The virtual assessment results described significantly greater completion rates (97% and 99%) for the finite state machines, but the movement time tended to be faster (2.7 s) for the postural control scheme. Our results substantiate that postural control schemes rival other state-of-the-art myoelectric controllers.

  14. Evaluation of head-free eye tracking as an input device for air traffic control.

    Science.gov (United States)

    Alonso, Roland; Causse, Mickaël; Vachon, François; Parise, Robert; Dehais, Frédéric; Terrier, Patrice

    2013-01-01

    The purpose of this study was to investigate the possibility to integrate a free head motion eye-tracking system as input device in air traffic control (ATC) activity. Sixteen participants used an eye tracker to select targets displayed on a screen as quickly and accurately as possible. We assessed the impact of the presence of visual feedback about gaze position and the method of target selection on selection performance under different difficulty levels induced by variations in target size and target-to-target separation. We tend to consider that the combined use of gaze dwell-time selection and continuous eye-gaze feedback was the best condition as it suits naturally with gaze displacement over the ATC display and free the hands of the controller, despite a small cost in terms of selection speed. In addition, target size had a greater impact on accuracy and selection time than target distance. These findings provide guidelines on possible further implementation of eye tracking in ATC everyday activity. We investigated the possibility to integrate a free head motion eye-tracking system as input device in air traffic control (ATC). We found that the combined use of gaze dwell-time selection and continuous eye-gaze feedback allowed the best performance and that target size had a greater impact on performance than target distance.

  15. In a demanding task, three-handed manipulation is preferred to two-handed manipulation.

    Science.gov (United States)

    Abdi, Elahe; Burdet, Etienne; Bouri, Mohamed; Himidan, Sharifa; Bleuler, Hannes

    2016-02-25

    Equipped with a third hand under their direct control, surgeons may be able to perform certain surgical interventions alone; this would reduce the need for a human assistant and related coordination difficulties. However, does human performance improve with three hands compared to two hands? To evaluate this possibility, we carried out a behavioural study on the performance of naive adults catching objects with three virtual hands controlled by their two hands and right foot. The subjects could successfully control the virtual hands in a few trials. With this control strategy, the workspace of the hands was inversely correlated with the task velocity. The comparison of performance between the three and two hands control revealed no significant difference of success in catching falling objects and in average effort during the tasks. Subjects preferred the three handed control strategy, found it easier, with less physical and mental burden. Although the coordination of the foot with the natural hands increased trial after trial, about two minutes of practice was not sufficient to develop a sense of ownership towards the third arm.

  16. Precise Localization and Formation Control of Swarm Robots via Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Han Wu

    2014-01-01

    Full Text Available Precise localization and formation control are one of the key technologies to achieve coordination and control of swarm robots, which is also currently a bottleneck for practical applications of swarm robotic systems. Aiming at overcoming the limited individual perception and the difficulty of achieving precise localization and formation, a localization approach combining dead reckoning (DR with wireless sensor network- (WSN- based methods is proposed in this paper. Two kinds of WSN localization technologies are adopted in this paper, that is, ZigBee-based RSSI (received signal strength indication global localization and electronic tag floors for calibration of local positioning. First, the DR localization information is combined with the ZigBee-based RSSI position information using the Kalman filter method to achieve precise global localization and maintain the robot formation. Then the electronic tag floors provide the robots with their precise coordinates in some local areas and enable the robot swarm to calibrate its formation by reducing the accumulated position errors. Hence, the overall performance of localization and formation control of the swarm robotic system is improved. Both of the simulation results and the experimental results on a real schematic system are given to demonstrate the success of the proposed approach.

  17. Feasibility study of a hand guided robotic drill for cochleostomy.

    Science.gov (United States)

    Brett, Peter; Du, Xinli; Zoka-Assadi, Masoud; Coulson, Chris; Reid, Andrew; Proops, David

    2014-01-01

    The concept of a hand guided robotic drill has been inspired by an automated, arm supported robotic drill recently applied in clinical practice to produce cochleostomies without penetrating the endosteum ready for inserting cochlear electrodes. The smart tactile sensing scheme within the drill enables precise control of the state of interaction between tissues and tools in real-time. This paper reports development studies of the hand guided robotic drill where the same consistent outcomes, augmentation of surgeon control and skill, and similar reduction of induced disturbances on the hearing organ are achieved. The device operates with differing presentation of tissues resulting from variation in anatomy and demonstrates the ability to control or avoid penetration of tissue layers as required and to respond to intended rather than involuntary motion of the surgeon operator. The advantage of hand guided over an arm supported system is that it offers flexibility in adjusting the drilling trajectory. This can be important to initiate cutting on a hard convex tissue surface without slipping and then to proceed on the desired trajectory after cutting has commenced. The results for trials on phantoms show that drill unit compliance is an important factor in the design.

  18. A Discrete-Time Chattering Free Sliding Mode Control with Multirate Sampling Method for Flight Simulator

    Directory of Open Access Journals (Sweden)

    Yunjie Wu

    2013-01-01

    Full Text Available In order to improve the tracking accuracy of flight simulator and expend its frequency response, a multirate-sampling-method-based discrete-time chattering free sliding mode control is developed and imported into the systems. By constructing the multirate sampling sliding mode controller, the flight simulator can perfectly track a given reference signal with an arbitrarily small dynamic tracking error, and the problems caused by a contradiction of reference signal period and control period in traditional design method can be eliminated. It is proved by theoretical analysis that the extremely high dynamic tracking precision can be obtained. Meanwhile, the robustness is guaranteed by sliding mode control even though there are modeling mismatch, external disturbances and measure noise. The validity of the proposed method is confirmed by experiments on flight simulator.

  19. Robotic hand project

    OpenAIRE

    Karaçizmeli, Cengiz; Çakır, Gökçe; Tükel, Dilek

    2014-01-01

    In this work, the mechatronic based robotic hand is controlled by the position data taken from the glove which has flex sensors mounted to capture finger bending of the human hand. The angular movement of human hand’s fingers are perceived and processed by a microcontroller, and the robotic hand is controlled by actuating servo motors. It has seen that robotic hand can simulate the movement of the human hand that put on the glove, during tests have done. This robotic hand can be used not only...

  20. Wireless embedded control system for atomically precise manufacturing

    KAUST Repository

    Khan, Yasser; Randall, John N.

    2011-01-01

    This paper will explore the possibilities of implementing a wireless embedded control system for atomically precise manufacturing. The manufacturing process, similar to Scanning Tunneling Microscopy, takes place within an Ultra High Vacuum (UHV) chamber at a pressure of 10-10 torr. In order to create vibration isolation, and to keep internal noise to a minimum, a wireless link inside the UHV chamber becomes essential. We present a MATLAB simulation of the problem, and then demonstrate a hardware scheme between a Gumstix computer and a Linux based laptop for controlling nano-manipulators with three degrees of freedom. © 2011 IEEE.

  1. Wireless embedded control system for atomically precise manufacturing

    KAUST Repository

    Khan, Yasser

    2011-04-01

    This paper will explore the possibilities of implementing a wireless embedded control system for atomically precise manufacturing. The manufacturing process, similar to Scanning Tunneling Microscopy, takes place within an Ultra High Vacuum (UHV) chamber at a pressure of 10-10 torr. In order to create vibration isolation, and to keep internal noise to a minimum, a wireless link inside the UHV chamber becomes essential. We present a MATLAB simulation of the problem, and then demonstrate a hardware scheme between a Gumstix computer and a Linux based laptop for controlling nano-manipulators with three degrees of freedom. © 2011 IEEE.

  2. Development of Hand Grip Assistive Device Control System for Old People through Electromyography (EMG Signal Acquisitions

    Directory of Open Access Journals (Sweden)

    Khamis Herman

    2017-01-01

    Full Text Available The hand grip assistive device is a glove to assist old people who suffer from hand weakness in their daily life activities. The device earlier control system only use simple on and off switch. This required old people to use both hand to activate the device. The new control system of the hand grip assistive device was developed to allow single hand operation for old people. New control system take advantages of electromyography (EMG and flex sensor which was implemented to the device. It was programmed into active and semi-active mode operation. EMG sensors were placed on the forearm to capture EMG signal of Flexor Digitorum Profundus muscle to activate the device. Flex sensor was used to indicate the finger position and placed on top of the finger. The signal from both sensors then used to control the device. The new control system allowed single hand operation and designed to prevent user from over depended on the device by activating it through moving their fingers.

  3. HandTutor™ enhanced hand rehabilitation after stroke--a pilot study.

    Science.gov (United States)

    Carmeli, Eli; Peleg, Sara; Bartur, Gadi; Elbo, Enbal; Vatine, Jean-Jacques

    2011-12-01

    This study assessed the potential therapeutic benefi t of using HandTutor™ in combination with traditional rehabilitation in a post-stroke sub-acute population. The study compares an experimental group receiving traditional therapy combined with HandTutorTM treatment, against a control group receiving only traditional therapy. An assessor-blinded, randomized controlled pilot trial, was conducted in the Reuth rehabilitation unit in Israel. Thirty-one stroke patients in the sub-acute phase, were randomly assigned to one of the two groups (experimental or control) in sets of three. The experimental group (n = 16) underwent a hand rehabilitation programme using the HandTutorTM combined with traditional therapy. The control group (n = 15) received only traditional therapy. The treatment schedules for both groups were of similar duration and frequency. Improvements were evaluated using three indicators: 1) The Brunnström-Fugl-Meyer (FM) test, 2) the Box and Blocks (B&B) test and 3) improvement parameters as determined by the HandTutorTM software. Following 15 consecutive treatment sessions, a signifi cant improvement was observed within the experimental group (95% confi dence intervals) compared with the control group: B&B p = 0.015; FM p = 0.041, HandTutor™ performance accuracy on x axis and performance accuracy on y axis p stroke hand function rehabilitation.

  4. A unified modeling and control design for precision transmission system with friction and backlash

    Directory of Open Access Journals (Sweden)

    Xiulan Bao

    2016-05-01

    Full Text Available The structural flexibility, nonlinear friction, and backlash are the major factors limiting the control performance of precision transmission systems. If uncompensated, these factors compromise the positioning and tracking accuracy of precision transmission systems and even cause limit cycles and oscillation. In this article, a framework for integrated design from dynamic modeling to controller design is proposed. A multi-state dynamic model is presented, which can unify the modeling for a multi-state, discontinuous system including the motor state, the motion state, the mechanical contact state, and the friction state. Then, a control design method related to the dynamic modeling using perturbation separation of the model parameters is presented. Using the proposed modeling method, a continuous dynamic model is established to include all different partition models. The model comprehensively describes the mechanical and electrical characteristics of the precision transmission system. A robust controller is designed using the proposed control method. Experimental results demonstrate that the proposed modeling method is accurate and the proposed control method significantly improves accuracy and robustness of the controller compared to traditional control methods.

  5. Complex modulation of fingertip forces during precision grasp and lift after theta burst stimulation over the dorsal premotor cortex

    Directory of Open Access Journals (Sweden)

    Drljačić Dragana

    2017-01-01

    Full Text Available Background/Aim. Adaptive control and fingertip force synchronization of precise grasp stability during unimanual manipulation of small objects represents an illustrative example of highly fractionated movements that are foundation of fine motor control. It is assumed that this process is controlled by several motor areas of the frontal lobe, particularly applicable to the primary motor (M-1 and dorsal premotor cortex (PMd. Aiming to examine the role of PMd during fine coordination of fingertip forces we applied theta burst repetitive magnetic stimulation (TBS to disrupt neural processing in that cortical area. Methods. Using a single-blind, randomized, crossover design, 10 healthy subjects (29 ± 3.9 years received single sessions of continuous TBS (cTBS600, intermittent TBS (iTBS600, or sham stimulation, separate from one another at least one week, over the PMd region of dominant hemisphere. Precision grasp and lift were assessed by instrumented device, recording grip (G and load (L forces, during three manipulation tasks (ramp-and-hold, oscillation force producing and simple lifting tasks, with each hand separately, before and after interventions. Results. We observed the improvement of task performance related to constant error (CE in oscillation task with the dominant hand (DH after the iTBS (p = 0.009. On the contrary, the cTBS reduced variable error (VE for non-dominant hand (NH, p = 0.005. Considering force coordination we found that iTBS worsened variables for NH (G/L ratio, p = 0.017; cross-correlation of the G and L, p = 0.047; Gain, p = 0.047. Conclusion. These results demonstrate the ability of TBS to modulate fingertip forces during precision grasping and lifting, when applied over PMd. These findings support the role of PMd in human motor control and forces generation required to hold small objects stable in our hands.

  6. Hands4U: the effects of a multifaceted implementation strategy on hand eczema prevalence in a healthcare setting. Results of a randomized controlled trial.

    Science.gov (United States)

    van der Meer, Esther W C; Boot, Cécile R L; van der Gulden, Joost W J; Knol, Dirk L; Jungbauer, Frank H W; Coenraads, Pieter Jan; Anema, Johannes R

    2015-05-01

    Healthcare workers have an increased risk of developing hand eczema. A multifaceted implementation strategy was developed to implement a guideline to prevent hand eczema among healthcare workers. To investigate the effects of the implementation strategy on self-reported hand eczema and preventive behaviour. A randomized controlled trial was performed. A total of 48 departments (n = 1649) were randomly allocated to the multifaceted implementation strategy or the control group. The strategy consisted of education, participatory working groups, and role models. Outcome measures were self-reported hand eczema and preventive behaviour. Data were collected at baseline, and 3, 6, 9 and 12 months of follow-up. Participants in the intervention group were significantly more likely to report hand eczema [odds ratio (OR) 1.45; 95% confidence interval (CI) 1.03-2.04], and they reported significantly less hand washing (B, - 0.38; 95%CI: - 0.48 to - 0.27), reported significantly more frequent use of a moisturizer (B, 0.30; 95%CI: 0.22-0.39) and were more likely to report wearing cotton undergloves (OR 6.33; 95%CI: 3.23-12.41) than participants in the control group 12 months after baseline. The strategy implemented can be used in practice, as it showed positive effects on preventive behaviour. More research is needed to investigate the unexpected effects on hand eczema. © 2014 The Authors. Contact Dermatitis published by John Wiley & Sons Ltd.

  7. Changes to online control and eye-hand coordination with healthy ageing.

    Science.gov (United States)

    O'Rielly, Jessica L; Ma-Wyatt, Anna

    2018-06-01

    Goal directed movements are typically accompanied by a saccade to the target location. Online control plays an important part in correction of a reach, especially if the target or goal of the reach moves during the reach. While there are notable changes to visual processing and motor control with healthy ageing, there is limited evidence about how eye-hand coordination during online updating changes with healthy ageing. We sought to quantify differences between older and younger people for eye-hand coordination during online updating. Participants completed a double step reaching task implemented under time pressure. The target perturbation could occur 200, 400 and 600 ms into a reach. We measured eye position and hand position throughout the trials to investigate changes to saccade latency, movement latency, movement time, reach characteristics and eye-hand latency and accuracy. Both groups were able to update their reach in response to a target perturbation that occurred at 200 or 400 ms into the reach. All participants demonstrated incomplete online updating for the 600 ms perturbation time. Saccade latencies, measured from the first target presentation, were generally longer for older participants. Older participants had significantly increased movement times but there was no significant difference between groups for touch accuracy. We speculate that the longer movement times enable the use of new visual information about the target location for online updating towards the end of the movement. Interestingly, older participants also produced a greater proportion of secondary saccades within the target perturbation condition and had generally shorter eye-hand latencies. This is perhaps a compensatory mechanism as there was no significant group effect on final saccade accuracy. Overall, the pattern of results suggests that online control of movements may be qualitatively different in older participants. Crown Copyright © 2018. Published by Elsevier B.V. All

  8. Closed-loop control of grasping with a myoelectric hand prosthesis: which are the relevant feedback variables for force control?

    Science.gov (United States)

    Ninu, Andrei; Dosen, Strahinja; Muceli, Silvia; Rattay, Frank; Dietl, Hans; Farina, Dario

    2014-09-01

    In closed-loop control of grasping by hand prostheses, the feedback information sent to the user is usually the actual controlled variable, i.e., the grasp force. Although this choice is intuitive and logical, the force production is only the last step in the process of grasping. Therefore, this study evaluated the performance in controlling grasp strength using a hand prosthesis operated through a complete grasping sequence while varying the feedback variables (e.g., closing velocity, grasping force), which were provided to the user visually or through vibrotactile stimulation. The experiments were conducted on 13 volunteers who controlled the Otto Bock Sensor Hand Speed prosthesis. Results showed that vibrotactile patterns were able to replace the visual feedback. Interestingly, the experiments demonstrated that direct force feedback was not essential for the control of grasping force. The subjects were indeed able to control the grip strength, predictively, by estimating the grasping force from the prosthesis velocity of closing. Therefore, grasping without explicit force feedback is not completely blind, contrary to what is usually assumed. In our study we analyzed grasping with a specific prosthetic device, but the outcomes are also applicable for other devices, with one or more degrees-of-freedom. The necessary condition is that the electromyography (EMG) signal directly and proportionally controls the velocity/grasp force of the hand, which is a common approach among EMG controlled prosthetic devices. The results provide important indications on the design of closed-loop EMG controlled prosthetic systems.

  9. A Compact Via-free Composite Right/Left Handed Low-pass Filter with Improved Selectivity

    Science.gov (United States)

    Kumar, Ashish; Choudhary, Dilip Kumar; Chaudhary, Raghvendra Kumar

    2017-07-01

    In this paper, a compact via-free low pass filter is designed based on composite right/left handed (CRLH) concept. The structure uses open ended concept. Rectangular slots are etched on signal transmission line (TL) to suppress the spurious band without altering the performance and size of filter. The filter is designed for low pass frequency band with cut-off frequency of 3.5 GHz. The proposed metamaterial structure has several prominent advantages in term of selectivity up to 34 dB/GHz and compactness with average insertion loss less than 0.4 dB. It has multiple applications in wireless communication (such as GSM900, global navigation satellite system (1.559-1.610 GHz), GSM1800, WLAN/WiFi (2.4-2.49 GHz) and WiMAX (2.5-2.69 GHz)). The design parameters have been measured and compared with the simulated results and found excellent agreement. The electrical size of proposed filter is 0.14λ0× 0.11λ0 (where λ0 is free space wavelength at zeroth order resonance (ZOR) frequency 2.7 GHz).

  10. Implantable electronics of a closed-loop system for controlling prosthetic hands

    Directory of Open Access Journals (Sweden)

    Nikas Antonios

    2017-09-01

    Full Text Available This paper presents the design of implantable electronics as a part of a system for prosthetic hand control. Purpose of the implant is the sensing of electrical signals originating from biological tissue and the actuation of the same, therefore closing the loop and allowing for an improved control of the prosthetic hand. The implant contains two integrated circuits for eight channel EMG monitoring and four channel stimulation, respectively. An on-board microcontroller allows for local pre-processing. All intracorporeal to extracorporeal communications are running through and are directed by the main processing platform. The external components of the control system include, in addition to the main processing and control platform, the inductive power transfer circuits and the pressure sensors for the sensory feedback. Different assembly and encapsulation options are taken into account for the implantable electronics and are unified in a single PCB design.

  11. Calculator-Controlled Robots: Hands-On Mathematics and Science Discovery

    Science.gov (United States)

    Tuchscherer, Tyson

    2010-01-01

    The Calculator Controlled Robots activities are designed to engage students in hands-on inquiry-based missions. These activities address National science and technology standards, as well as specifically focusing on mathematics content and process standards. There are ten missions and three exploration extensions that provide activities for up to…

  12. Musculoskeletal model-based control interface mimics physiologic hand dynamics during path tracing task

    Science.gov (United States)

    Crouch, Dustin L.; (Helen Huang, He

    2017-06-01

    Objective. We investigated the feasibility of a novel, customizable, simplified EMG-driven musculoskeletal model for estimating coordinated hand and wrist motions during a real-time path tracing task. Approach. A two-degree-of-freedom computational musculoskeletal model was implemented for real-time EMG-driven control of a stick figure hand displayed on a computer screen. After 5-10 minutes of undirected practice, subjects were given three attempts to trace 10 straight paths, one at a time, with the fingertip of the virtual hand. Able-bodied subjects completed the task on two separate test days. Main results. Across subjects and test days, there was a significant linear relationship between log-transformed measures of accuracy and speed (Pearson’s r  =  0.25, p  bodied subjects in 8 of 10 trials. For able-bodied subjects, tracing accuracy was lower at the extremes of the model’s range of motion, though there was no apparent relationship between tracing accuracy and fingertip location for the amputee. Our result suggests that, unlike able-bodied subjects, the amputee’s motor control patterns were not accustomed to the multi-joint dynamics of the wrist and hand, possibly as a result of post-amputation cortical plasticity, disuse, or sensory deficits. Significance. To our knowledge, our study is one of very few that have demonstrated the real-time simultaneous control of multi-joint movements, especially wrist and finger movements, using an EMG-driven musculoskeletal model, which differs from the many data-driven algorithms that dominate the literature on EMG-driven prosthesis control. Real-time control was achieved with very little training and simple, quick (~15 s) calibration. Thus, our model is potentially a practical and effective control platform for multifunctional myoelectric prostheses that could restore more life-like hand function for individuals with upper limb amputation.

  13. Evaluating EMG Feature and Classifier Selection for Application to Partial-Hand Prosthesis Control

    Directory of Open Access Journals (Sweden)

    Adenike A. Adewuyi

    2016-10-01

    Full Text Available Pattern recognition-based myoelectric control of upper limb prostheses has the potential to restore control of multiple degrees of freedom. Though this control method has been extensively studied in individuals with higher-level amputations, few studies have investigated its effectiveness for individuals with partial-hand amputations. Most partial-hand amputees retain a functional wrist and the ability of pattern recognition-based methods to correctly classify hand motions from different wrist positions is not well studied. In this study, focusing on partial-hand amputees, we evaluate (1 the performance of non-linear and linear pattern recognition algorithms and (2 the performance of optimal EMG feature subsets for classification of four hand motion classes in different wrist positions for 16 non-amputees and 4 amputees. Our results show that linear discriminant analysis and linear and non-linear artificial neural networks perform significantly better than the quadratic discriminant analysis for both non-amputees and partial-hand amputees. For amputees, including information from multiple wrist positions significantly decreased error (p<0.001 but no further significant decrease in error occurred when more than 4, 2, or 3 positions were included for the extrinsic (p=0.07, intrinsic (p=0.06, or combined extrinsic and intrinsic muscle EMG (p=0.08, respectively. Finally, we found that a feature set determined by selecting optimal features from each channel outperformed the commonly used time domain (p<0.001 and time domain/autoregressive feature sets (p<0.01. This method can be used as a screening filter to select the features from each channel that provide the best classification of hand postures across different wrist positions.

  14. A Low-cost Environmental Control System for Precise Radial Velocity Spectrometers

    Science.gov (United States)

    Sliski, David H.; Blake, Cullen H.; Halverson, Samuel

    2017-12-01

    We present an environmental control system (ECS) designed to achieve milliKelvin (mK) level temperature stability for small-scale astronomical instruments. This ECS is inexpensive and is primarily built from commercially available components. The primary application for our ECS is the high-precision Doppler spectrometer MINERVA-Red, where the thermal variations of the optical components within the instrument represent a major source of systematic error. We demonstrate ±2 mK temperature stability within a 0.5 m3 thermal enclosure using resistive heaters in conjunction with a commercially available PID controller and off-the-shelf thermal sensors. The enclosure is maintained above ambient temperature, enabling rapid cooling through heat dissipation into the surrounding environment. We demonstrate peak-to-valley (PV) temperature stability of better than 5 mK within the MINERVA-Red vacuum chamber, which is located inside the thermal enclosure, despite large temperature swings in the ambient laboratory environment. During periods of stable laboratory conditions, the PV variations within the vacuum chamber are less than 3 mK. This temperature stability is comparable to the best stability demonstrated for Doppler spectrometers currently achieving m s-1 radial velocity precision. We discuss the challenges of using commercially available thermoelectrically cooled CCD cameras in a temperature-stabilized environment, and demonstrate that the effects of variable heat output from the CCD camera body can be mitigated using PID-controlled chilled water systems. The ECS presented here could potentially provide the stable operating environment required for future compact “astrophotonic” precise radial velocity (PRV) spectrometers to achieve high Doppler measurement precision with a modest budget.

  15. Accessibility Is the Mother of Invention: When It Comes to an Innovative Hand Control System

    Science.gov (United States)

    Exceptional Parent, 2007

    2007-01-01

    This article features Sure Grip hand control, an innovative hand control system created by Keith Howell, the President and founder of Howell Ventures LTD. Howell was in his early teens when he experienced an accident that resulted in his quadriplegia. From that point on, Howell set about to manufacture a set of controls that would emulate the…

  16. Application of precise MPD & pressure balance cementing technology

    Directory of Open Access Journals (Sweden)

    Yong Ma

    2018-03-01

    Full Text Available The precise managed pressure drilling (MPD technology is mainly used to deal with the difficulties encountered when oil and gas open hole sections with multiple pressure systems and the strata with narrow safety density window are drilled through. If its liner cementing is carried out according to the conventional method, lost circulation is inevitable in the process of cementing while the displacement efficiency of small-clearance liner cementing is satisfied. If the positive and inverse injection technology is adopted, the cementing quality cannot meet the requirements of later well test engineering of ultradeep wells. In this paper, the cementing operation of Ø114.3 mm liner in Well Longgang 70 which was drilled in the Jiange structure of the Sichuan Basin was taken as an example to explore the application of the cementing technology based on the precise MPD and pressure balancing method to the cementing of long open-hole sections (as long as 859 m with both high and low pressures running through multiple reservoirs. On the one hand, the technical measures were taken specifically to ensure the annulus filling efficiency of slurry and the pressure balance in the whole process of cementing. And on the other hand, the annulus pressure balance was precisely controlled by virtue of precise MPD devices and by injecting heavy weight drilling fluids through central pipes, and thus the wellbore pressure was kept steady in the whole process of cementing in the strata with narrow safety density window. It is indicated that Ø114.3 mm liner cementing in this well is good with qualified pressure tests and no channeling emerges at a funnel during the staged density reduction. It is concluded that this method can enhance the liner cementing quality of complex ultradeep gas wells and improve the wellbore conditions for the later safe well tests of high-pressure gas wells. Keywords: Ultradeep well, Liner cementing, Narrow safety density window, Precise

  17. Development of EPICS based beam-line experimental control employing motor controller for precision positioning

    International Nuclear Information System (INIS)

    Tuli, Anupriya; Jain, Rajiv; Vora, H.S.

    2015-01-01

    In a Synchrotron Radiation Source the beamline experiments are carried out in radiation prone environment, inside the hutch, which demands to conduct experiments remotely. These experiments involves instrument control and data acquisition from various devices. Another factor which attributes to system complexity is precise positioning of sample and placement of detectors. A large number of stepper motors are engaged for achieving the required precision positioning. This work is a result of development of Experimental Physics and Industrial Control System (EPICS) based control system to interface a stepper motor controller developed indigenously by Laser Electronics Support Division of RRCAT. EPICS is an internationally accepted open source software environment which follows toolkit approach and standard model paradigm. The operator interface for the control system software was implemented using CSS BOY. The system was successfully tested for Ethernet based remote access. The developed control software comprises of an OPI and alarm handler (EPICS ALH). Both OPI and ALH are linked with PV's defined in database files. The development process resulted into a set of EPICS based commands for controlling stepper motor. These commands are independent of operator interface, i.e. stepper motor can be controlled by using these set of commands directly on EPICS prompt. This command set is illustrated in the above table. EPICS Alarm Handler was also tested independently by running these commands on EPIC prompt. If not using ALH, operator can read the alarm status of a PV using 'SEVR' and 'STAT' attributes. (author)

  18. A randomized, controlled trial of a multifaceted intervention including alcohol-based hand sanitizer and hand-hygiene education to reduce illness transmission in the home.

    Science.gov (United States)

    Sandora, Thomas J; Taveras, Elsie M; Shih, Mei-Chiung; Resnick, Elissa A; Lee, Grace M; Ross-Degnan, Dennis; Goldmann, Donald A

    2005-09-01

    Good hand hygiene may reduce the spread of infections in families with children who are in out-of-home child care. Alcohol-based hand sanitizers rapidly kill viruses that are commonly associated with respiratory and gastrointestinal (GI) infections. The objective of this study was to determine whether a multifactorial campaign centered on increasing alcohol-based hand sanitizer use and hand-hygiene education reduces illness transmission in the home. A cluster randomized, controlled trial was conducted of homes of 292 families with children who were enrolled in out-of-home child care in 26 child care centers. Eligible families had > or =1 child who was 6 months to 5 years of age and in child care for > or =10 hours/week. Intervention families received a supply of hand sanitizer and biweekly hand-hygiene educational materials for 5 months; control families received only materials promoting good nutrition. Primary caregivers were phoned biweekly and reported respiratory and GI illnesses in family members. Respiratory and GI-illness-transmission rates (measured as secondary illnesses per susceptible person-month) were compared between groups, adjusting for demographic variables, hand-hygiene practices, and previous experience using hand sanitizers. Baseline demographics were similar in the 2 groups. A total of 1802 respiratory illnesses occurred during the study; 443 (25%) were secondary illnesses. A total of 252 GI illnesses occurred during the study; 28 (11%) were secondary illnesses. The secondary GI-illness rate was significantly lower in intervention families compared with control families (incidence rate ratio [IRR]: 0.41; 95% confidence interval [CI]: 0.19-0.90). The overall rate of secondary respiratory illness was not significantly different between groups (IRR: 0.97; 95% CI: 0.72-1.30). However, families with higher sanitizer usage had a marginally lower secondary respiratory illness rate than those with less usage (IRR: 0.81; 95% CI: 0.65-1.09). A

  19. Advances in the Control System for a High Precision Dissolved Organic Carbon Analyzer

    Science.gov (United States)

    Liao, M.; Stubbins, A.; Haidekker, M.

    2017-12-01

    Dissolved organic carbon (DOC) is a master variable in aquatic ecosystems. DOC in the ocean is one of the largest carbon stores on earth. Studies of the dynamics of DOC in the ocean and other low DOC systems (e.g. groundwater) are hindered by the lack of high precision (sub-micromolar) analytical techniques. Results are presented from efforts to construct and optimize a flow-through, wet chemical DOC analyzer. This study focused on the design, integration and optimization of high precision components and control systems required for such a system (mass flow controller, syringe pumps, gas extraction, reactor chamber with controlled UV and temperature). Results of the approaches developed are presented.

  20. Feasibility Study of a Hand Guided Robotic Drill for Cochleostomy

    Directory of Open Access Journals (Sweden)

    Peter Brett

    2014-01-01

    Full Text Available The concept of a hand guided robotic drill has been inspired by an automated, arm supported robotic drill recently applied in clinical practice to produce cochleostomies without penetrating the endosteum ready for inserting cochlear electrodes. The smart tactile sensing scheme within the drill enables precise control of the state of interaction between tissues and tools in real-time. This paper reports development studies of the hand guided robotic drill where the same consistent outcomes, augmentation of surgeon control and skill, and similar reduction of induced disturbances on the hearing organ are achieved. The device operates with differing presentation of tissues resulting from variation in anatomy and demonstrates the ability to control or avoid penetration of tissue layers as required and to respond to intended rather than involuntary motion of the surgeon operator. The advantage of hand guided over an arm supported system is that it offers flexibility in adjusting the drilling trajectory. This can be important to initiate cutting on a hard convex tissue surface without slipping and then to proceed on the desired trajectory after cutting has commenced. The results for trials on phantoms show that drill unit compliance is an important factor in the design.

  1. Dynamics Modeling and first Design of Drag-Free Controller for ASTROD I

    Science.gov (United States)

    Li, H.; Theil, S.; Pettazzi, L.; Guilherme, M.-S.; Ni, W.-T.

    The Astrodynamical Space Test of Relativity using Optical Devices I ASTROD I mainly aims at testing relativistic gravity and measuring the solar-system parameters with high precision by carrying out laser ranging between a spacecraft in a solar orbit and ground stations It is the first step of ASTROD with 3 spacecraft In order to design the Drag-Free and Attitude Control system DFACS for the spacecraft a numerical simulator of spacecraft and test mass dynamics as well as models of main forces and torques are established using Matlab Simulink The aims of the DFACS are to reduce the acceleration disturbance on the test mass to a level of 10 -13 m cdot s -2 cdot Hz -1 2 at a frequency of 0 1 mHz in one axis and keep the telescope pointing to the ground stations on the earth The dynamics of spacecraft and test mass is a coupled multiple degree of freedom non-linear system So the first step of the DFACS design is to reduce the order of the system with assumptions without loss of generality Then the system is linearized at nominal state With the linear state space model of the system a Linear Quadratic Gaussian Regulator LQG is derived LQR and the feed-forward of a constant disturbance constitute the controller This paper will present the numerical simulator and the first drag-free controller design for ASTROD I It will show the development of the simulator the derivation of the controller as well as first simulation results

  2. Efficacy of paraffin bath therapy in hand osteoarthritis: a single-blinded randomized controlled trial.

    Science.gov (United States)

    Dilek, Banu; Gözüm, Mehtap; Şahin, Ebru; Baydar, Meltem; Ergör, Gül; El, Ozlem; Bircan, Çigdem; Gülbahar, Selmin

    2013-04-01

    To evaluate the efficacy of paraffin bath therapy on pain, function, and muscle strength in patients with hand osteoarthritis. Prospective single-blinded randomized controlled trial. Department of physical medicine and rehabilitation in a university hospital. Patients with bilateral hand osteoarthritis (N=56). Patients were randomized into 2 groups with a random number table by using block randomization with 4 patients in a block. Group 1 (n=29) had paraffin bath therapy (5 times per week, for 3-week duration) for both hands. Group 2 (n=27) was the control group. All patients were informed about joint-protection techniques, and paracetamol intake was recorded. The primary outcome measures were pain (at last 48h) at rest and during activities of daily living (ADL), assessed with a visual analog scale (0-10cm) at 12 weeks. The secondary outcome measures were the Australian Canadian Osteoarthritis Hand Index (AUSCAN) and the Dreiser Functional Index (DFI), used for subjective functional evaluation, loss of range of motion (ROM), grip and pinch strength, painful and tender joint counts, and paracetamol intake. A researcher blind to group allocation recorded the measures for both hands at baseline, 3 weeks, and 12 weeks at the hospital setting. At baseline, there were no significant differences between groups in any of the parameters (P>.05). After treatment, the paraffin group exhibited significant improvement in pain at rest and during ADL, ROM of the right hand, and pain and stiffness dimensions of the AUSCAN (P.05). The control group showed a significant deterioration in right hand grip and bilateral lateral pinch and right chuck pinch strength (Pparaffin group (Pparaffin group were significantly higher than the control group at 12 weeks (PParaffin bath therapy seemed to be effective both in reducing pain and tenderness and maintaining muscle strength in hand osteoarthritis. It may be regarded as a beneficial short-term therapy option, which is effective for a 12

  3. Precision grid and hand motion for accurate needle insertion in brachytherapy

    International Nuclear Information System (INIS)

    McGill, Carl S.; Schwartz, Jonathon A.; Moore, Jason Z.; McLaughlin, Patrick W.; Shih, Albert J.

    2011-01-01

    Purpose: In prostate brachytherapy, a grid is used to guide a needle tip toward a preplanned location within the tissue. During insertion, the needle deflects en route resulting in target misplacement. In this paper, 18-gauge needle insertion experiments into phantom were performed to test effects of three parameters, which include the clearance between the grid hole and needle, the thickness of the grid, and the needle insertion speed. Measurement apparatus that consisted of two datum surfaces and digital depth gauge was developed to quantify needle deflections. Methods: The gauge repeatability and reproducibility (GR and R) test was performed on the measurement apparatus, and it proved to be capable of measuring a 2 mm tolerance from the target. Replicated experiments were performed on a 2 3 factorial design (three parameters at two levels) and analysis included averages and standard deviation along with an analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: Results showed that grid with tight clearance hole and slow needle speed increased precision and accuracy of needle insertion. The tight grid was vital to enhance precision and accuracy of needle insertion for both slow and fast insertion speed; additionally, at slow speed the tight, thick grid improved needle precision and accuracy. Conclusions: In summary, the tight grid is important, regardless of speed. The grid design, which shows the capability to reduce the needle deflection in brachytherapy procedures, can potentially be implemented in the brachytherapy procedure.

  4. Poor Hand-Pointing to Sounds in Right Brain-Damaged Patients: Not Just a Problem of Spatial-Hearing

    Science.gov (United States)

    Pavani, Francesco; Farne, Alessandro; Ladavas, Elisabetta

    2005-01-01

    We asked 22 right brain-damaged (RBD) patients and 11 elderly healthy controls to perform hand-pointing movements to free-field unseen sounds, while modulating two non-auditory variables: the initial position of the responding hand (left, centre or right) and the presence or absence of task-irrelevant ambient vision. RBD patients suffering from…

  5. Clean Hands Count

    Medline Plus

    Full Text Available ... starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with ... ads? Get YouTube Red. Working... Not now Try it free Find out why Close Clean Hands Count ...

  6. Estimating thumb–index finger precision grip and manipulation potential in extant and fossil primates

    Science.gov (United States)

    Feix, Thomas; Kivell, Tracy L.; Pouydebat, Emmanuelle; Dollar, Aaron M.

    2015-01-01

    Primates, and particularly humans, are characterized by superior manual dexterity compared with other mammals. However, drawing the biomechanical link between hand morphology/behaviour and functional capabilities in non-human primates and fossil taxa has been challenging. We present a kinematic model of thumb–index precision grip and manipulative movement based on bony hand morphology in a broad sample of extant primates and fossil hominins. The model reveals that both joint mobility and digit proportions (scaled to hand size) are critical for determining precision grip and manipulation potential, but that having either a long thumb or great joint mobility alone does not necessarily yield high precision manipulation. The results suggest even the oldest available fossil hominins may have shared comparable precision grip manipulation with modern humans. In particular, the predicted human-like precision manipulation of Australopithecus afarensis, approximately one million years before the first stone tools, supports controversial archaeological evidence of tool-use in this taxon. PMID:25878134

  7. Effect of smoke-free patio policy of restaurants and bars on exposure to second-hand smoke.

    Science.gov (United States)

    Azagba, Sunday

    2015-07-01

    While there is increasing support for restricting smoking in restaurant and bar patios, there is limited evidence on the effectiveness of this policy. This study examined the effect of smoke-free patio policy of restaurants and bars on adult second-hand smoke (SHS) exposure. Data were drawn from the 2005-2012 Canadian Tobacco Use Monitoring Survey (n=89,743), a repeated cross-sectional survey of youth and adult. Regression analysis, a quasi-experimental design was used to examine the effect of provincial smoke-free patio policy on self-reported exposure to SHS. Analyses suggest that exposure to SHS on patios of bars and restaurants declined following the adoption of provincial smoke-free patio policy. Relative to pre-policy SHS exposure, regression results showed a reduction in the probability of SHS exposure of up to 25% in Alberta. Similarly, in Nova Scotia, the probability of SHS exposure declined by up to 21%. Analyses stratified by smoking status found similar significant effect on both smokers and non-smokers. Findings suggest that provincial patio smoking ban on bars and restaurants had the intended effect of protecting non-smokers from SHS exposure. This study is consistent with a large body of evidence showing that a strong smoke-free legislation is an effective public health measure. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  8. Hysteresis-free high-temperature precise bimorph actuators produced by direct bonding of lithium niobate wafers

    Energy Technology Data Exchange (ETDEWEB)

    Shur, V. Ya.; Baturin, I. S.; Mingaliev, E. A.; Zorikhin, D. V.; Udalov, A. R.; Greshnyakov, E. D. [Ferroelectric Laboratory, Institute of Natural Sciences, Ural Federal University, 51 Lenin Ave., 620000 Ekaterinburg (Russian Federation)

    2015-02-02

    The current paper presents a piezoelectric bimorph actuator produced by direct bonding of lithium niobate wafers with the mirrored Y and Z axes. Direct bonding technology allowed to fabricate bidomain plate with precise positioning of ideally flat domain boundary. By optimizing the cutting angle (128° Y-cut), the piezoelectric constant became as large as 27.3 pC/N. Investigation of voltage dependence of bending displacement confirmed that bimorph actuator has excellent linearity and hysteresis-free. Decrease of the applied voltage down to mV range showed the perfect linearity up to the sub-nm deflection amplitude. The frequency and temperature dependences of electromechanical transmission coefficient in wide temperature range (from 300 to 900 K) were investigated.

  9. High precision innovative micropump for artificial pancreas

    Science.gov (United States)

    Chappel, E.; Mefti, S.; Lettieri, G.-L.; Proennecke, S.; Conan, C.

    2014-03-01

    The concept of artificial pancreas, which comprises an insulin pump, a continuous glucose meter and a control algorithm, is a major step forward in managing patient with type 1 diabetes mellitus. The stability of the control algorithm is based on short-term precision micropump to deliver rapid-acting insulin and to specific integrated sensors able to monitor any failure leading to a loss of accuracy. Debiotech's MEMS micropump, based on the membrane pump principle, is made of a stack of 3 silicon wafers. The pumping chamber comprises a pillar check-valve at the inlet, a pumping membrane which is actuated against stop limiters by a piezo cantilever, an anti-free-flow outlet valve and a pressure sensor. The micropump inlet is tightly connected to the insulin reservoir while the outlet is in direct communication with the patient skin via a cannula. To meet the requirement of a pump dedicated to closed-loop application for diabetes care, in addition to the well-controlled displacement of the pumping membrane, the high precision of the micropump is based on specific actuation profiles that balance effect of pump elasticity in low-consumption push-pull mode.

  10. Triple-Frequency GPS Precise Point Positioning Ambiguity Resolution Using Dual-Frequency Based IGS Precise Clock Products

    Directory of Open Access Journals (Sweden)

    Fei Liu

    2017-01-01

    Full Text Available With the availability of the third civil signal in the Global Positioning System, triple-frequency Precise Point Positioning ambiguity resolution methods have drawn increasing attention due to significantly reduced convergence time. However, the corresponding triple-frequency based precise clock products are not widely available and adopted by applications. Currently, most precise products are generated based on ionosphere-free combination of dual-frequency L1/L2 signals, which however are not consistent with the triple-frequency ionosphere-free carrier-phase measurements, resulting in inaccurate positioning and unstable float ambiguities. In this study, a GPS triple-frequency PPP ambiguity resolution method is developed using the widely used dual-frequency based clock products. In this method, the interfrequency clock biases between the triple-frequency and dual-frequency ionosphere-free carrier-phase measurements are first estimated and then applied to triple-frequency ionosphere-free carrier-phase measurements to obtain stable float ambiguities. After this, the wide-lane L2/L5 and wide-lane L1/L2 integer property of ambiguities are recovered by estimating the satellite fractional cycle biases. A test using a sparse network is conducted to verify the effectiveness of the method. The results show that the ambiguity resolution can be achieved in minutes even tens of seconds and the positioning accuracy is in decimeter level.

  11. Oscillations-free PID control of anesthetic drug delivery in neuromuscular blockade.

    Science.gov (United States)

    Medvedev, Alexander; Zhusubaliyev, Zhanybai T; Rosén, Olov; Silva, Margarida M

    2016-07-25

    The PID-control of drug delivery or the neuromuscular blockade (NMB) in closed-loop anesthesia is considered. The NMB system dynamics portrayed by a Wiener model can exhibit sustained nonlinear oscillations under realistic PID gains and for physiologically feasible values of the model parameters. Such oscillations, also repeatedly observed in clinical trials, lead to under- and over-dosing of the administered drug and undermine patient safety. This paper proposes a tuning policy for the proportional PID gain that via bifurcation analysis ensures oscillations-free performance of the control loop. Online estimates of the Wiener model parameters are needed for the controller implementation and monitoring of the closed-loop proximity to oscillation. The nonlinear dynamics of the PID-controlled NMB system are studied by bifurcation analysis. A database of patient models estimated under PID-controlled neuromuscular blockade during general anesthesia is utilized, along with the corresponding clinical measurements. The performance of three recursive algorithms is compared in the application at hand: an extended Kalman filter, a conventional particle filter (PF), and a PF making use of an orthonormal basis to estimate the probability density function from the particle set. It is shown that with a time-varying proportional PID gain, the type of equilibria of the closed-loop system remains the same as in the case of constant controller gains. The recovery time and frequency of oscillations are also evaluated in simulation over the database of patient models. Nonlinear identification techniques based on model linearization yield biased parameter estimates and thus introduce superfluous uncertainty. The bias and variance of the estimated models are related to the computational complexity of the identification algorithms, highlighting the superiority of the PFs in this safety-critical application. The study demonstrates feasibility of the proposed oscillation-free control

  12. Testing of an End-Point Control Unit Designed to Enable Precision Control of Manipulator-Coupled Spacecraft

    Science.gov (United States)

    Montgomery, Raymond C.; Ghosh, Dave; Tobbe, Patrick A.; Weathers, John M.; Manouchehri, Davoud; Lindsay, Thomas S.

    1994-01-01

    This paper presents an end-point control concept designed to enable precision telerobotic control of manipulator-coupled spacecraft. The concept employs a hardware unit (end-point control unit EPCU) that is positioned between the end-effector of the Space Shuttle Remote Manipulator System and the payload. Features of the unit are active compliance (control of the displacement between the end-effector and the payload), to allow precision control of payload motions, and inertial load relief, to prevent the transmission of loads between the end-effector and the payload. This paper presents the concept and studies the active compliance feature using a simulation and hardware. Results of the simulation show the effectiveness of the EPCU in smoothing the motion of the payload. Results are presented from initial, limited tests of a laboratory hardware unit on a robotic arm testbed at the l Space Flight Center. Tracking performance of the arm in a constant speed automated retraction and extension maneuver of a heavy payload with and without the unit active is compared for the design speed and higher speeds. Simultaneous load reduction and tracking performance are demonstrated using the EPCU.

  13. The human hand as an inspiration for robot hand development

    CERN Document Server

    Santos, Veronica

    2014-01-01

    “The Human Hand as an Inspiration for Robot Hand Development” presents an edited collection of authoritative contributions in the area of robot hands. The results described in the volume are expected to lead to more robust, dependable, and inexpensive distributed systems such as those endowed with complex and advanced sensing, actuation, computation, and communication capabilities. The twenty-four chapters discuss the field of robotic grasping and manipulation viewed in light of the human hand’s capabilities and push the state-of-the-art in robot hand design and control. Topics discussed include human hand biomechanics, neural control, sensory feedback and perception, and robotic grasp and manipulation. This book will be useful for researchers from diverse areas such as robotics, biomechanics, neuroscience, and anthropologists.

  14. Precision grinding of microarray lens molding die with 4-axes controlled microwheel

    Directory of Open Access Journals (Sweden)

    Yuji Yamamoto, Hirofumi Suzuki, Takashi Onishi1, Tadashi Okino and Toshimichi Moriwaki

    2007-01-01

    Full Text Available This paper deals with precision grinding of microarray lens (fly eye molding die by using a resinoid bonded diamond wheel. An ultra-precision grinding system of microarray lens molding die and new truing method of resinoid bonded diamond wheel were developed. In this system, a grinding wheel was four-dimensionally controlled with 1 nm resolution by linear scale feedback system and scanned on the workpiece surface. New truing method by using a vanadium alloy tool was developed and its performance was obtained with high preciseness and low wheel wear. Finally, the microarray lens molding dies of fine grain tungsten carbide (WC was tested with the resinoid bonded diamond wheel to evaluate grinding performance.

  15. Hand Gesture Based Wireless Robotic Arm Control for Agricultural Applications

    Science.gov (United States)

    Kannan Megalingam, Rajesh; Bandhyopadhyay, Shiva; Vamsy Vivek, Gedela; Juned Rahi, Muhammad

    2017-08-01

    One of the major challenges in agriculture is harvesting. It is very hard and sometimes even unsafe for workers to go to each plant and pluck fruits. Robotic systems are increasingly combined with new technologies to automate or semi automate labour intensive work, such as e.g. grape harvesting. In this work we propose a semi-automatic method for aid in harvesting fruits and hence increase productivity per man hour. A robotic arm fixed to a rover roams in the in orchard and the user can control it remotely using the hand glove fixed with various sensors. These sensors can position the robotic arm remotely to harvest the fruits. In this paper we discuss the design of hand glove fixed with various sensors, design of 4 DoF robotic arm and the wireless control interface. In addition the setup of the system and the testing and evaluation under lab conditions are also presented in this paper.

  16. Ultra-precise tracking control of piezoelectric actuators via a fuzzy hysteresis model.

    Science.gov (United States)

    Li, Pengzhi; Yan, Feng; Ge, Chuan; Zhang, Mingchao

    2012-08-01

    In this paper, a novel Takagi-Sugeno (T-S) fuzzy system based model is proposed for hysteresis in piezoelectric actuators. The antecedent and consequent structures of the fuzzy hysteresis model (FHM) can be, respectively, identified on-line through uniform partition approach and recursive least squares (RLS) algorithm. With respect to controller design, the inverse of FHM is used to develop a feedforward controller to cancel out the hysteresis effect. Then a hybrid controller is designed for high-performance tracking. It combines the feedforward controller with a proportional integral differential (PID) controller favourable for stabilization and disturbance compensation. To achieve nanometer-scale tracking precision, the enhanced adaptive hybrid controller is further developed. It uses real-time input and output data to update FHM, thus changing the feedforward controller to suit the on-site hysteresis character of the piezoelectric actuator. Finally, as to 3 cases of 50 Hz sinusoidal, multiple frequency sinusoidal and 50 Hz triangular trajectories tracking, experimental results demonstrate the efficiency of the proposed controllers. Especially, being only 0.35% of the maximum desired displacement, the maximum error of 50 Hz sinusoidal tracking is greatly reduced to 5.8 nm, which clearly shows the ultra-precise nanometer-scale tracking performance of the developed adaptive hybrid controller.

  17. Dexterous Control of Seven Functional Hand Movements Using Cortically-Controlled Transcutaneous Muscle Stimulation in a Person With Tetraplegia

    Directory of Open Access Journals (Sweden)

    Samuel C. Colachis

    2018-04-01

    Full Text Available Individuals with tetraplegia identify restoration of hand function as a critical, unmet need to regain their independence and improve quality of life. Brain-Computer Interface (BCI-controlled Functional Electrical Stimulation (FES technology addresses this need by reconnecting the brain with paralyzed limbs to restore function. In this study, we quantified performance of an intuitive, cortically-controlled, transcutaneous FES system on standardized object manipulation tasks from the Grasp and Release Test (GRT. We found that a tetraplegic individual could use the system to control up to seven functional hand movements, each with >95% individual accuracy. He was able to select one movement from the possible seven movements available to him and use it to appropriately manipulate all GRT objects in real-time using naturalistic grasps. With the use of the system, the participant not only improved his GRT performance over his baseline, demonstrating an increase in number of transfers for all objects except the Block, but also significantly improved transfer times for the heaviest objects (videocassette (VHS, Can. Analysis of underlying motor cortex neural representations associated with the hand grasp states revealed an overlap or non-separability in neural activation patterns for similarly shaped objects that affected BCI-FES performance. These results suggest that motor cortex neural representations for functional grips are likely more related to hand shape and force required to hold objects, rather than to the objects themselves. These results, demonstrating multiple, naturalistic functional hand movements with the BCI-FES, constitute a further step toward translating BCI-FES technologies from research devices to clinical neuroprosthetics.

  18. Precision Munition Electro-Sciences Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This facility allows the characterization of the electro-magnetic environment produced by a precision weapon in free flight. It can measure the radiofrequency (RF)...

  19. Tuning SISO offset-free Model Predictive Control based on ARX models

    DEFF Research Database (Denmark)

    Huusom, Jakob Kjøbsted; Poulsen, Niels Kjølstad; Jørgensen, Sten Bay

    2012-01-01

    , the proposed controller is simple to tune as it has only one free tuning parameter. These two features are advantageous in predictive process control as they simplify industrial commissioning of MPC. Disturbance rejection and offset-free control is important in industrial process control. To achieve offset......In this paper, we present a tuning methodology for a simple offset-free SISO Model Predictive Controller (MPC) based on autoregressive models with exogenous inputs (ARX models). ARX models simplify system identification as they can be identified from data using convex optimization. Furthermore......-free control in face of unknown disturbances or model-plant mismatch, integrators must be introduced in either the estimator or the regulator. Traditionally, offset-free control is achieved using Brownian disturbance models in the estimator. In this paper we achieve offset-free control by extending the noise...

  20. Design and validation of a morphing myoelectric hand posture controller based on principal component analysis of human grasping.

    Science.gov (United States)

    Segil, Jacob L; Weir, Richard F ff

    2014-03-01

    An ideal myoelectric prosthetic hand should have the ability to continuously morph between any posture like an anatomical hand. This paper describes the design and validation of a morphing myoelectric hand controller based on principal component analysis of human grasping. The controller commands continuously morphing hand postures including functional grasps using between two and four surface electromyography (EMG) electrodes pairs. Four unique maps were developed to transform the EMG control signals in the principal component domain. A preliminary validation experiment was performed by 10 nonamputee subjects to determine the map with highest performance. The subjects used the myoelectric controller to morph a virtual hand between functional grasps in a series of randomized trials. The number of joints controlled accurately was evaluated to characterize the performance of each map. Additional metrics were studied including completion rate, time to completion, and path efficiency. The highest performing map controlled over 13 out of 15 joints accurately.

  1. Effects of prosthesis use on the capability to control myoelectric robotic prosthetic hands.

    Science.gov (United States)

    Atzori, Manfredo; Hager, Anne-Gabrielle Mittaz; Elsig, Simone; Giatsidis, Giorgio; Bassetto, Franco; Muller, Henning

    2015-08-01

    The natural control of robotic prosthetic hands with non-invasive techniques is still a challenge: myoelectric prostheses currently give some control capabilities; the application of pattern recognition techniques is promising and recently started to be applied in practice but still many questions are open in the field. In particular, the effects of clinical factors on movement classification accuracy and the capability to control myoelectric prosthetic hands are analyzed in very few studies. The effect of regularly using prostheses on movement classification accuracy has been previously studied, showing differences between users of myoelectric and cosmetic prostheses. In this paper we compare users of myoelectric and body-powered prostheses and intact subjects. 36 machine-learning methods are applied on 6 amputees and 40 intact subjects performing 40 movements. Then, statistical analyses are performed in order to highlight significant differences between the groups of subjects. The statistical analyses do not show significant differences between the two groups of amputees, while significant differences are obtained between amputees and intact subjects. These results constitute new information in the field and suggest new interpretations to previous hypotheses, thus adding precious information towards natural control of robotic prosthetic hands.

  2. Smoke-Free Policies in New Zealand Public Tertiary Education Institutions

    Science.gov (United States)

    Robertson, Lindsay A.; Marsh, L.

    2015-01-01

    The Framework Convention on Tobacco Control mandates the creation of smoke-free environments to protect non-smokers from second-hand smoke and reduce demand for tobacco. We aimed to examine the extent and nature of smoke-free campus policies at tertiary education institutions throughout New Zealand, and examine the policy development process.…

  3. Data-driven gradient algorithm for high-precision quantum control

    Science.gov (United States)

    Wu, Re-Bing; Chu, Bing; Owens, David H.; Rabitz, Herschel

    2018-04-01

    In the quest to achieve scalable quantum information processing technologies, gradient-based optimal control algorithms (e.g., grape) are broadly used for implementing high-precision quantum gates, but their performance is often hindered by deterministic or random errors in the system model and the control electronics. In this paper, we show that grape can be taught to be more effective by jointly learning from the design model and the experimental data obtained from process tomography. The resulting data-driven gradient optimization algorithm (d-grape) can in principle correct all deterministic gate errors, with a mild efficiency loss. The d-grape algorithm may become more powerful with broadband controls that involve a large number of control parameters, while other algorithms usually slow down due to the increased size of the search space. These advantages are demonstrated by simulating the implementation of a two-qubit controlled-not gate.

  4. HAND2 Target Gene Regulatory Networks Control Atrioventricular Canal and Cardiac Valve Development.

    Science.gov (United States)

    Laurent, Frédéric; Girdziusaite, Ausra; Gamart, Julie; Barozzi, Iros; Osterwalder, Marco; Akiyama, Jennifer A; Lincoln, Joy; Lopez-Rios, Javier; Visel, Axel; Zuniga, Aimée; Zeller, Rolf

    2017-05-23

    The HAND2 transcriptional regulator controls cardiac development, and we uncover additional essential functions in the endothelial to mesenchymal transition (EMT) underlying cardiac cushion development in the atrioventricular canal (AVC). In Hand2-deficient mouse embryos, the EMT underlying AVC cardiac cushion formation is disrupted, and we combined ChIP-seq of embryonic hearts with transcriptome analysis of wild-type and mutants AVCs to identify the functionally relevant HAND2 target genes. The HAND2 target gene regulatory network (GRN) includes most genes with known functions in EMT processes and AVC cardiac cushion formation. One of these is Snai1, an EMT master regulator whose expression is lost from Hand2-deficient AVCs. Re-expression of Snai1 in mutant AVC explants partially restores this EMT and mesenchymal cell migration. Furthermore, the HAND2-interacting enhancers in the Snai1 genomic landscape are active in embryonic hearts and other Snai1-expressing tissues. These results show that HAND2 directly regulates the molecular cascades initiating AVC cardiac valve development. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  5. High-Precision Control of a Piezo-Driven Nanopositioner Using Fuzzy Logic Controllers

    Directory of Open Access Journals (Sweden)

    Mohammed Altaher

    2018-01-01

    Full Text Available This paper presents single- and dual-loop fuzzy control schemes to precisely control the piezo-driven nanopositioner in the x- and y-axis directions. Various issues are associated with this control problem, such as low stability margin due to the sharp resonant peak, nonlinear dynamics, parameter uncertainty, etc. As such, damping controllers are often utilised to damp the mechanical resonance of the nanopositioners. The Integral Resonant Controller (IRC is used in this paper as a damping controller to damp the mechanical resonance. A further inherent problem is the hysteresis phenomenon (disturbance, which leads to degrading the positioning performance (accuracy of the piezo-driven stage. The common approach to treat this disturbance is to invoke tracking controllers in a closed-loop feedback scheme in conjunction with the damping controllers. The traditional approach uses the Integral Controller (I or Proportional Integral (PI as a tracking controller, whereas this paper introduces the Proportional and Integral (PI-like Fuzzy Logic Controller (FLC as a tracking controller. The effectiveness of the proposed control schemes over conventional schemes is confirmed through comparative simulation studies, and results are presented. The stability boundaries of the proposed control schemes are determined in the same way as with a conventional controller. Robustness against variations in the resonant frequency of the proposed control schemes is verified.

  6. Bio-inspired grasp control in a robotic hand with massive sensorial input.

    Science.gov (United States)

    Ascari, Luca; Bertocchi, Ulisse; Corradi, Paolo; Laschi, Cecilia; Dario, Paolo

    2009-02-01

    The capability of grasping and lifting an object in a suitable, stable and controlled way is an outstanding feature for a robot, and thus far, one of the major problems to be solved in robotics. No robotic tools able to perform an advanced control of the grasp as, for instance, the human hand does, have been demonstrated to date. Due to its capital importance in science and in many applications, namely from biomedics to manufacturing, the issue has been matter of deep scientific investigations in both the field of neurophysiology and robotics. While the former is contributing with a profound understanding of the dynamics of real-time control of the slippage and grasp force in the human hand, the latter tries more and more to reproduce, or take inspiration by, the nature's approach, by means of hardware and software technology. On this regard, one of the major constraints robotics has to overcome is the real-time processing of a large amounts of data generated by the tactile sensors while grasping, which poses serious problems to the available computational power. In this paper a bio-inspired approach to tactile data processing has been followed in order to design and test a hardware-software robotic architecture that works on the parallel processing of a large amount of tactile sensing signals. The working principle of the architecture bases on the cellular nonlinear/neural network (CNN) paradigm, while using both hand shape and spatial-temporal features obtained from an array of microfabricated force sensors, in order to control the sensory-motor coordination of the robotic system. Prototypical grasping tasks were selected to measure the system performances applied to a computer-interfaced robotic hand. Successful grasps of several objects, completely unknown to the robot, e.g. soft and deformable objects like plastic bottles, soft balls, and Japanese tofu, have been demonstrated.

  7. Hand washing promotion for preventing diarrhoea.

    Science.gov (United States)

    Ejemot-Nwadiaro, Regina I; Ehiri, John E; Arikpo, Dachi; Meremikwu, Martin M; Critchley, Julia A

    2015-09-03

    provision of soap) at child day-care facilities or schools prevents around one-third of diarrhoea episodes in high income countries (rate ratio 0.70; 95% CI 0.58 to 0.85; nine trials, 4664 participants, high quality evidence), and may prevent a similar proportion in LMICs but only two trials from urban Egypt and Kenya have evaluated this (rate ratio 0.66, 95% CI 0.43 to 0.99; two trials, 45,380 participants, low quality evidence). Only three trials reported measures of behaviour change and the methods of data collection were susceptible to bias. In one trial from the USA hand washing behaviour was reported to improve; and in the trial from Kenya that provided free soap, hand washing did not increase, but soap use did (data not pooled; three trials, 1845 participants, low quality evidence).Hand washing promotion among communities in LMICs probably prevents around one-quarter of diarrhoea episodes (rate ratio 0.72, 95% CI 0.62 to 0.83; eight trials, 14,726 participants, moderate quality evidence). However, six of these eight trials were from Asian settings, with only single trials from South America and sub-Saharan Africa. In six trials, soap was provided free alongside hand washing education, and the overall average effect size was larger than in the two trials which did not provide soap (soap provided: rate ratio 0.66, 95% CI 0.56 to 0.78; six trials, 11,422 participants; education only: rate ratio: 0.84, 95% CI 0.67 to 1.05; two trials, 3304 participants). There was increased hand washing at major prompts (before eating/cooking, after visiting the toilet or cleaning the baby's bottom), and increased compliance to hand hygiene procedure (behavioural outcome) in the intervention groups than the control in community trials (data not pooled: three trials, 3490 participants, high quality evidence).Hand washing promotion for the one trial conducted in a hospital among high-risk population showed significant reduction in mean episodes of diarrhoea (1.68 fewer) in the intervention

  8. DNA Nanotechnology for Precise Control over Drug Delivery and Gene Therapy.

    Science.gov (United States)

    Angell, Chava; Xie, Sibai; Zhang, Liangfang; Chen, Yi

    2016-03-02

    Nanomedicine has been growing exponentially due to its enhanced drug targeting and reduced drug toxicity. It uses the interactions where nanotechnological components and biological systems communicate with each other to facilitate the delivery performance. At this scale, the physiochemical properties of delivery systems strongly affect their capacities. Among current delivery systems, DNA nanotechnology shows many advantages because of its unprecedented engineering abilities. Through molecular recognition, DNA nanotechnology can be used to construct a variety of nanostructures with precisely controllable size, shape, and surface chemistry, which can be appreciated in the delivery process. In this review, different approaches that are currently used for the construction of DNA nanostructures are reported. Further, the utilization of these DNA nanostructures with the well-defined parameters for the precise control in drug delivery and gene therapy is discussed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. The effectiveness of origami on overall hand function after injury: A pilot controlled trial

    OpenAIRE

    Wilson, L; Roden, P; Taylor, Y; Marston, L

    2008-01-01

    This pilot study measured the effectiveness of using origami to improve the overall hand function of outpatients attending an NHS hand injury unit. The initiative came from one of the authors who had used origami informally in the clinical setting and observed beneficial effects. These observed effects were tested experimentally. The design was a pilot non-randomised controlled trial with 13 participants. Allocation of the seven control group members was based on patient preference. The exper...

  10. Effects of prolonged wakefulness combined with alcohol and hands-free cell phone divided attention tasks on simulated driving.

    Science.gov (United States)

    Iudice, A; Bonanni, E; Gelli, A; Frittelli, C; Iudice, G; Cignoni, F; Ghicopulos, I; Murri, L

    2005-03-01

    Simulated driving ability was assessed following administration of alcohol, at an estimated blood level of 0.05%, and combined prolonged wakefulness, while participants were undertaking divided attention tasks over a hands-free mobile phone. Divided attention tasks were structured to provide a sustained cognitive workload to the subjects. Twenty three young healthy individuals drove 10 km simulated driving under four conditions in a counterbalanced, within-subject design: alcohol, alcohol and 19 h wakefulness, alcohol and 24 h wakefulness, and while sober. Study measures were: simulated driving, self-reported sleepiness, critical flicker fusion threshold (CFFT), Stroop word-colour interference test (Stroop) and simple visual reaction times (SVRT). As expected, subjective sleepiness was highly correlated with both sleep restriction and alcohol consumption. The combination of alcohol and 24 h sustained wakefulness produced the highest driving impairment, significantly beyond the alcohol effect itself. Concurrent alcohol and 19 h wakefulness significantly affected only driving time-to-collision. No significant changes of study measures occurred following alcohol intake in unrestricted sleep conditions. CFFT, SVRT and Stroop results showed a similar trend in the four study conditions. Thus apparently 'safe' blood alcohol levels in combination with prolonged wakefulness resulted in significant driving impairments. In normal sleep conditions alcohol effects on driving were partially counteracted by the concomitant hands-free phone based psychometric tasks. 2005 John Wiley & Sons, Ltd.

  11. Vibration control for precision manufacturing at Sandia National Laboratories

    International Nuclear Information System (INIS)

    Hinnerichs, T.; Martinez, D.

    1995-01-01

    Sandia National Laboratories performs R and D in structural dynamics and vibration suppression for precision applications in weapon systems, space, underwater, transportation and civil structures. Over the last decade these efforts have expanded into the areas of active vibration control and ''smart'' structures and material systems. In addition, Sandia has focused major resources towards technology to support weapon product development and agile manufacturing capability for defense and industrial applications. This paper will briefly describe the structural dynamics modeling and verification process currently in place at Sandia that supports vibration control and some specific applications of these techniques to manufacturing in the areas of lithography, machine tools and flexible robotics

  12. Vibration control for precision manufacturing at Sandia National Laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Hinnerichs, T.; Martinez, D. [Sandia National Labs., Albuquerque, NM (United States). Structural Dynamics and Vibration Control Dept.

    1995-04-01

    Sandia National Laboratories performs R and D in structural dynamics and vibration suppression for precision applications in weapon systems, space, underwater, transportation and civil structures. Over the last decade these efforts have expanded into the areas of active vibration control and ``smart`` structures and material systems. In addition, Sandia has focused major resources towards technology to support weapon product development and agile manufacturing capability for defense and industrial applications. This paper will briefly describe the structural dynamics modeling and verification process currently in place at Sandia that supports vibration control and some specific applications of these techniques to manufacturing in the areas of lithography, machine tools and flexible robotics.

  13. Estimating thumb-index finger precision grip and manipulation potential in extant and fossil primates.

    Science.gov (United States)

    Feix, Thomas; Kivell, Tracy L; Pouydebat, Emmanuelle; Dollar, Aaron M

    2015-05-06

    Primates, and particularly humans, are characterized by superior manual dexterity compared with other mammals. However, drawing the biomechanical link between hand morphology/behaviour and functional capabilities in non-human primates and fossil taxa has been challenging. We present a kinematic model of thumb-index precision grip and manipulative movement based on bony hand morphology in a broad sample of extant primates and fossil hominins. The model reveals that both joint mobility and digit proportions (scaled to hand size) are critical for determining precision grip and manipulation potential, but that having either a long thumb or great joint mobility alone does not necessarily yield high precision manipulation. The results suggest even the oldest available fossil hominins may have shared comparable precision grip manipulation with modern humans. In particular, the predicted human-like precision manipulation of Australopithecus afarensis, approximately one million years before the first stone tools, supports controversial archaeological evidence of tool-use in this taxon. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  14. Robot training for hand motor recovery in subacute stroke patients: A randomized controlled trial.

    Science.gov (United States)

    Orihuela-Espina, Felipe; Roldán, Giovana Femat; Sánchez-Villavicencio, Israel; Palafox, Lorena; Leder, Ronald; Sucar, Luis Enrique; Hernández-Franco, Jorge

    2016-01-01

    Evidence of superiority of robot training for the hand over classical therapies in stroke patients remains controversial. During the subacute stage, hand training is likely to be the most useful. To establish whether robot active assisted therapies provides any additional motor recovery for the hand when administered during the subacute stage (robot based therapies for hand recovery will show significant differences at subacute stages. A randomized clinical trial. A between subjects randomized controlled trial was carried out on subacute stroke patients (n = 17) comparing robot active assisted therapy (RT) with a classical occupational therapy (OT). Both groups received 40 sessions ensuring at least 300 repetitions per session. Treatment duration was (mean ± std) 2.18 ± 1.25 months for the control group and 2.44 ± 0.88 months for the study group. The primary outcome was motor dexterity changes assessed with the Fugl-Meyer (FMA) and the Motricity Index (MI). Both groups (OT: n = 8; RT: n = 9) exhibited significant improvements over time (Non-parametric Cliff's delta-within effect sizes: dwOT-FMA = 0.5, dwOT-MI = 0.5, dwRT-FMA = 1, dwRT-MI = 1). Regarding differences between the therapies; the Fugl-Meyer score indicated a significant advantage for the hand training with the robot (FMA hand: WRS: W = 8, p hand prehension for RT with respect to OT but failed to reach significance (MI prehension: W = 17.5, p = 0.080). No harm occurred. Robotic therapies may be useful during the subacute stages of stroke - both endpoints (FM hand and MI prehension) showed the expected trend with bigger effect size for the robotic intervention. Additional benefit of the robotic therapy over the control therapy was only significant when the difference was measured with FM, demanding further investigation with larger samples. Implications of this study are important for decision making during therapy administration and resource allocation. Copyright © 2016 Hanley

  15. Hand washing promotion for preventing diarrhoea

    Science.gov (United States)

    Ejemot-Nwadiaro, Regina I; Ehiri, John E; Arikpo, Dachi; Meremikwu, Martin M; Critchley, Julia A

    2015-01-01

    syndrome (AIDS) (148 participants). Hand washing promotion (education activities, sometimes with provision of soap) at child day-care facilities or schools prevents around one-third of diarrhoea episodes in high income countries (rate ratio 0.70; 95% CI 0.58 to 0.85; nine trials, 4664 participants, high quality evidence), and may prevent a similar proportion in LMICs but only two trials from urban Egypt and Kenya have evaluated this (rate ratio 0.66, 95% CI 0.43 to 0.99; two trials, 45,380 participants, low quality evidence). Only three trials reported measures of behaviour change and the methods of data collection were susceptible to bias. In one trial from the USA hand washing behaviour was reported to improve; and in the trial from Kenya that provided free soap, hand washing did not increase, but soap use did (data not pooled; three trials, 1845 participants, low quality evidence). Hand washing promotion among communities in LMICs probably prevents around one-quarter of diarrhoea episodes (rate ratio 0.72, 95% CI 0.62 to 0.83; eight trials, 14,726 participants, moderate quality evidence). However, six of these eight trials were from Asian settings, with only single trials from South America and sub-Saharan Africa. In six trials, soap was provided free alongside hand washing education, and the overall average effect size was larger than in the two trials which did not provide soap (soap provided: rate ratio 0.66, 95% CI 0.56 to 0.78; six trials, 11,422 participants; education only: rate ratio: 0.84, 95% CI 0.67 to 1.05; two trials, 3304 participants). There was increased hand washing at major prompts (before eating/cooking, after visiting the toilet or cleaning the baby's bottom), and increased compliance to hand hygiene procedure (behavioural outcome) in the intervention groups than the control in community trials (data not pooled: three trials, 3490 participants, high quality evidence). Hand washing promotion for the one trial conducted in a hospital among high

  16. Atomically precise cluster catalysis towards quantum controlled catalysts

    International Nuclear Information System (INIS)

    Watanabe, Yoshihide

    2014-01-01

    Catalysis of atomically precise clusters supported on a substrate is reviewed in relation to the type of reactions. The catalytic activity of supported clusters has generally been discussed in terms of electronic structure. Several lines of evidence have indicated that the electronic structure of clusters and the geometry of clusters on a support, including the accompanying cluster-support interaction, are strongly correlated with catalytic activity. The electronic states of small clusters would be easily affected by cluster–support interactions. Several studies have suggested that it is possible to tune the electronic structure through atomic control of the cluster size. It is promising to tune not only the number of cluster atoms, but also the hybridization between the electronic states of the adsorbed reactant molecules and clusters in order to realize a quantum-controlled catalyst. (review)

  17. An Approach to Precise Nitrogen Management Using Hand-Held Crop Sensor Measurements and Winter Wheat Yield Mapping in a Mediterranean Environment

    Directory of Open Access Journals (Sweden)

    Lucía Quebrajo

    2015-03-01

    Full Text Available Regardless of the crop production system, nutrients inputs must be controlled at or below a certain economic threshold to achieve an acceptable level of profitability. The use of management zones and variable-rate fertilizer applications is gaining popularity in precision agriculture. Many researchers have evaluated the application of final yield maps and geo-referenced geophysical measurements (e.g., apparent soil electrical conductivity-ECa as a method of establishing relatively homogeneous management zones within the same plot. Yield estimation models based on crop conditions at certain growth stages, soil nutrient statuses, agronomic factors, moisture statuses, and weed/pest pressures are a primary goal in precision agriculture. This study attempted to achieve the following objectives: (1 to investigate the potential for predicting winter wheat yields using vegetation measurements (the Normalized Difference Vegetation Index—NDVI at the beginning of the season, thereby allowing for a yield response to nitrogen (N fertilizer; and (2 evaluate the feasibility of using inexpensive optical sensor measurements in a Mediterranean environment. A field experiment was conducted in two commercial wheat fields near Seville, in southwestern Spain. Yield data were collected at harvest using a yield monitoring system (RDS Ceres II-volumetric meter installed on a combine. Wheat yield and NDVI values of 3498 ± 481 kg ha−1 and 0.67 ± 0.04 nm nm−1 (field 1 and 3221 ± 531 kg ha−1 and 0.68 ± 0.05 nm nm−1 (field 2 were obtained. In both fields, the yield and NDVI exhibited a strong Pearson correlation, with rxy = 0.64 and p < 10−4 in field 1 and rxy = 0.78 and p < 10−4 in field 2. The preliminary results indicate that hand-held crop sensor-based N management can be applied to wheat production in Spain and has the potential to increase agronomic N-use efficiency on a long-term basis.

  18. Control of free-flying space robot manipulator systems

    Science.gov (United States)

    Cannon, Robert H., Jr.

    1990-01-01

    New control techniques for self contained, autonomous free flying space robots were developed and tested experimentally. Free flying robots are envisioned as a key element of any successful long term presence in space. These robots must be capable of performing the assembly, maintenance, and inspection, and repair tasks that currently require human extravehicular activity (EVA). A set of research projects were developed and carried out using lab models of satellite robots and a flexible manipulator. The second generation space robot models use air cushion vehicle (ACV) technology to simulate in 2-D the drag free, zero g conditions of space. The current work is divided into 5 major projects: Global Navigation and Control of a Free Floating Robot, Cooperative Manipulation from a Free Flying Robot, Multiple Robot Cooperation, Thrusterless Robotic Locomotion, and Dynamic Payload Manipulation. These projects are examined in detail.

  19. Inspections of Hand Washing Supplies and Hand Sanitizer in Public Schools

    Science.gov (United States)

    Ramos, Mary M.; Blea, Mary; Trujillo, Rebecca; Greenberg, Cynthia

    2010-01-01

    Hand washing and hand antisepsis are proven infection control measures in the school setting, yet barriers such as lack of soap, paper towels, and hand sanitizer can hinder compliance. This pilot study measured the prevalence of hand cleaning supplies in public schools. Ten school districts (93 schools) participated in school nurse inspections. In…

  20. Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method

    Science.gov (United States)

    Hu, Ying Kai; Xie, Qian Yang; Yang, Chi; Xu, Guang Zhou

    2017-01-01

    Abstract The aim of this study was to introduce a novel method of mesiodens extraction using a vascularized pedicled bone flap by piezosurgery and to compare the differences between a computer-aided design surgical guide template and free-hand operation. A total of 8 patients with mesiodens, 4 with a surgical guide (group I), and 4 without it (group II) were included in the study. The surgical design was to construct a trapdoor pedicle on the superior mucoperiosteal attachment with application of piezosurgery. The bone lid was repositioned after mesiodens extraction. Group I patients underwent surgeries based on the preoperative planning with surgical guide templates, while group II patients underwent free-hand operation. The outcome variables were success rate, intraoperative time, anterior nasal spine (ANS) position, changes of nasolabial angle (NLA), and major complications. Data from the 2 groups were compared by SPSS 17.0, using Wilcoxon test. The operative time was significantly shorter in group I patients. All the mesiodentes were extracted successfully and no obvious differences of preoperative and postoperative ANS position and NLA value were found in both groups. The patients were all recovered uneventfully. Surgical guide templates can enhance clinical accuracy and reduce operative time by facilitating accurate osteotomies. PMID:28658139

  1. Design and control of the precise tracking bed based on complex electromechanical design theory

    Science.gov (United States)

    Ren, Changzhi; Liu, Zhao; Wu, Liao; Chen, Ken

    2010-05-01

    The precise tracking technology is wide used in astronomical instruments, satellite tracking and aeronautic test bed. However, the precise ultra low speed tracking drive system is one high integrated electromechanical system, which one complexly electromechanical design method is adopted to improve the efficiency, reliability and quality of the system during the design and manufacture circle. The precise Tracking Bed is one ultra-exact, ultra-low speed, high precision and huge inertial instrument, which some kind of mechanism and environment of the ultra low speed is different from general technology. This paper explores the design process based on complex electromechanical optimizing design theory, one non-PID with a CMAC forward feedback control method is used in the servo system of the precise tracking bed and some simulation results are discussed.

  2. Illusory movement perception improves motor control for prosthetic hands

    Science.gov (United States)

    Marasco, Paul D.; Hebert, Jacqueline S.; Sensinger, Jon W.; Shell, Courtney E.; Schofield, Jonathon S.; Thumser, Zachary C.; Nataraj, Raviraj; Beckler, Dylan T.; Dawson, Michael R.; Blustein, Dan H.; Gill, Satinder; Mensh, Brett D.; Granja-Vazquez, Rafael; Newcomb, Madeline D.; Carey, Jason P.; Orzell, Beth M.

    2018-01-01

    To effortlessly complete an intentional movement, the brain needs feedback from the body regarding the movement’s progress. This largely non-conscious kinesthetic sense helps the brain to learn relationships between motor commands and outcomes to correct movement errors. Prosthetic systems for restoring function have predominantly focused on controlling motorized joint movement. Without the kinesthetic sense, however, these devices do not become intuitively controllable. Here we report a method for endowing human amputees with a kinesthetic perception of dexterous robotic hands. Vibrating the muscles used for prosthetic control via a neural-machine interface produced the illusory perception of complex grip movements. Within minutes, three amputees integrated this kinesthetic feedback and improved movement control. Combining intent, kinesthesia, and vision instilled participants with a sense of agency over the robotic movements. This feedback approach for closed-loop control opens a pathway to seamless integration of minds and machines. PMID:29540617

  3. Eye-in-Hand Manipulation for Remote Handling: Experimental Setup

    Science.gov (United States)

    Niu, Longchuan; Suominen, Olli; Aref, Mohammad M.; Mattila, Jouni; Ruiz, Emilio; Esque, Salvador

    2018-03-01

    A prototype for eye-in-hand manipulation in the context of remote handling in the International Thermonuclear Experimental Reactor (ITER)1 is presented in this paper. The setup consists of an industrial robot manipulator with a modified open control architecture and equipped with a pair of stereoscopic cameras, a force/torque sensor, and pneumatic tools. It is controlled through a haptic device in a mock-up environment. The industrial robot controller has been replaced by a single industrial PC running Xenomai that has a real-time connection to both the robot controller and another Linux PC running as the controller for the haptic device. The new remote handling control environment enables further development of advanced control schemes for autonomous and semi-autonomous manipulation tasks. This setup benefits from a stereovision system for accurate tracking of the target objects with irregular shapes. The overall environmental setup successfully demonstrates the required robustness and precision that remote handling tasks need.

  4. Robotically enhanced rubber hand illusion.

    Science.gov (United States)

    Arata, Jumpei; Hattori, Masashi; Ichikawa, Shohei; Sakaguchi, Masamichi

    2014-01-01

    The rubber hand illusion is a well-known multisensory illusion. In brief, watching a rubber hand being stroked by a paintbrush while one's own unseen hand is synchronously stroked causes the rubber hand to be attributed to one's own body and to "feel like it's my hand." The rubber hand illusion is thought to be triggered by the synchronized tactile stimulation of both the subject's hand and the fake hand. To extend the conventional rubber hand illusion, we introduce robotic technology in the form of a master-slave telemanipulator. The developed one degree-of-freedom master-slave system consists of an exoskeleton master equipped with an optical encoder that is worn on the subject's index finger and a motor-actuated index finger on the rubber hand, which allows the subject to perform unilateral telemanipulation. The moving rubber hand illusion has been studied by several researchers in the past with mechanically connected rigs between the subject's body and the fake limb. The robotic instruments let us investigate the moving rubber hand illusion with less constraints, thus behaving closer to the classic rubber hand illusion. In addition, the temporal delay between the body and the fake limb can be precisely manipulated. The experimental results revealed that the robotic instruments significantly enhance the rubber hand illusion. The time delay is significantly correlated with the effect of the multisensory illusion, and the effect significantly decreased at time delays over 100 ms. These findings can potentially contribute to the investigations of neural mechanisms in the field of neuroscience and of master-slave systems in the field of robotics.

  5. Development of practical field minimised personal hands free headset for mobile phones with high performance robustness

    International Nuclear Information System (INIS)

    Gosnell, M.E.; Huber, G.

    2001-01-01

    This paper presents the development of a practical means of minimising exposure of the user's head to radiated emissions from mobile phones. The invention allows the production of a commercially viable product similar to the existing and widely accepted hands free headsets. The description of the design evolution concentrates on various techniques for attenuating the power emissions at the earpiece and the corresponding results will be disclosed including measurements taken with the mobile held in several typical positions. The design focuses on maximising immunity to phone and wire position with maximum attenuation in the commercial mobile bands. Copyright (2001) Australasian Radiation Protection Society Inc

  6. Golf Injuries to the Hand, Wrist, or Elbow

    Science.gov (United States)

    ... Therapist? Media Find a Hand Surgeon Home Anatomy Golf Injuries to the Hand, Wrist or Elbow Email ... enjoyment of the game injury free. Types of Golf Injuries Golf injuries can include tendonitis, sprains or ...

  7. A measurement control program to meet desired levels of precision and accuracy

    International Nuclear Information System (INIS)

    Bruckner, L.A.

    1991-01-01

    Measurement control programs are usually designed to test for precision and accuracy. Many instruments, however, display non-random data patterns such as biases or seasonal variations which are statistically significant but are of no practical significance. Application of the usual statistical tests can cause these instruments to be removed from service unnecessarily. It is tempting to try to overcome this problem by frequently adjusting the instrument or by arbitrarily changing the parameters of the statistical tests so that failures occur less often. This, of course invalidates the statistical tests. In the author's opinion, the correct way to handle this problem is to identify the desired levels of precision and accuracy, and then to combine these levels with valid statistical techniques in the measurement control-program. This paper describes one way to accomplish this

  8. Bacteriological aspects of hand washing: A key for health promotion and infections control

    Directory of Open Access Journals (Sweden)

    Ramezan Ali Ataee

    2017-01-01

    Full Text Available The aim of this review is to show the historical aspects of hands washing for healthy life and explains how can reduce the transmission of community-acquired infectious agents by healthcare workers and patients. This review article is prepared based on available database. The key words used were hands washing, risk assessment, hands hygiene, bacterial flora, contamination, infection, nosocomial, tap water, sanitizer, bacterial resistance, hands bacterial flora, washing methods, antiseptics, healthcare workers, healthcare personnel, from PubMed, ScienceDirect, Embase, Scopus, Web of Sciences, and Google Scholar. Data were descriptively analyzed. The insistence on hand washing has a history of 1400 years. The research results indicate that the bacteria released from the female washed hands in wet and dry condition was lower than from the male′s hands with a significance level (3 CFU vs. 8 CFU; confidence interval 95%, P ≤ 0.001. The valuable results of the study indicated that released amount of bacterial flora from wet hands is more than 10 times in compared to dry hands. In addition, established monitoring systems for washing hands before and after patient′s manipulation as well as after toilet were dominant indices to prevent the transfer of infectious agents to the patients. Increasing awareness and belief of the healthcare workers have shown an important role by about 30% reduction in the transfection. Hand washing could reduce the episodes of transmission of infectious agents in both community and healthcare settings. However, hand washing is an important key factor to prevent transmission of infectious agents to patients. There is no standard method for measuring compliance. Thus, permanent monitoring of hand washing to reduce the transmission of infections is crucial. Finally, the personnel must believe that hand washing is an inevitable approach to infection control.

  9. Control Capabilities of Myoelectric Robotic Prostheses by Hand Amputees: A Scientific Research and Market Overview.

    Science.gov (United States)

    Atzori, Manfredo; Müller, Henning

    2015-01-01

    Hand amputation can dramatically affect the capabilities of a person. Cortical reorganization occurs in the brain, but the motor and somatosensorial cortex can interact with the remnant muscles of the missing hand even many years after the amputation, leading to the possibility to restore the capabilities of hand amputees through myoelectric prostheses. Myoelectric hand prostheses with many degrees of freedom are commercially available and recent advances in rehabilitation robotics suggest that their natural control can be performed in real life. The first commercial products exploiting pattern recognition to recognize the movements have recently been released, however the most common control systems are still usually unnatural and must be learned through long training. Dexterous and naturally controlled robotic prostheses can become reality in the everyday life of amputees but the path still requires many steps. This mini-review aims to improve the situation by giving an overview of the advancements in the commercial and scientific domains in order to outline the current and future chances in this field and to foster the integration between market and scientific research.

  10. Control Capabilities of Myoelectric Robotic Prostheses by Hand Amputees: A Scientific Research and Market Overview

    Directory of Open Access Journals (Sweden)

    Manfredo eAtzori

    2015-11-01

    Full Text Available Hand amputation can dramatically affect the capabilities of a person. Cortical reorganization occurs in the brain, but the motor and somatosensorial cortex can interact with the remnant muscles of the missing hand even many years after the amputation, leading to the possibility to restore the capabilities of hand amputees through myoelectric prostheses. Myoelectric hand prostheses with many degrees of freedom are commercially available and recent advances in rehabilitation robotics suggest that their natural control can be performed in real life. The first commercial products exploiting pattern recognition to recognize the movements have recently been released, however the most common control systems are still usually unnatural and must be learned through long training. Dexterous and naturally controlled robotic prostheses can become reality in the everyday life of amputees but the path still requires many steps. This mini-review aims to improve the situation by giving an overview of the advancements in the commercial and scientific domains in order to outline the current and future chances in this field and to foster the integration between market and scientific research.

  11. sEMG Signal Acquisition Strategy towards Hand FES Control

    Directory of Open Access Journals (Sweden)

    Cinthya Lourdes Toledo-Peral

    2018-01-01

    Full Text Available Due to damage of the nervous system, patients experience impediments in their daily life: severe fatigue, tremor or impaired hand dexterity, hemiparesis, or hemiplegia. Surface electromyography (sEMG signal analysis is used to identify motion; however, standardization of electrode placement and classification of sEMG patterns are major challenges. This paper describes a technique used to acquire sEMG signals for five hand motion patterns from six able-bodied subjects using an array of recording and stimulation electrodes placed on the forearm and its effects over functional electrical stimulation (FES and volitional sEMG combinations, in order to eventually control a sEMG-driven FES neuroprosthesis for upper limb rehabilitation. A two-part protocol was performed. First, personalized templates to place eight sEMG bipolar channels were designed; with these data, a universal template, called forearm electrode set (FELT, was built. Second, volitional and evoked movements were recorded during FES application. 95% classification accuracy was achieved using two sessions per movement. With the FELT, it was possible to perform FES and sEMG recordings simultaneously. Also, it was possible to extract the volitional and evoked sEMG from the raw signal, which is highly important for closed-loop FES control.

  12. Distortion control in 20MnCr5 bevel gears after liquid nitriding process to maintain precision dimensions

    Science.gov (United States)

    Mahendiran, M.; Kavitha, M.

    2018-02-01

    Robotic and automotive gears are generally very high precision components with limitations in tolerances. Bevel gears are more widely used and dimensionally very close tolerance components that need stability without any backlash or distortion for smooth and trouble free functions. Nitriding is carried out to enhance wear resistance of the surface. The aim of this paper is to reduce the distortion in liquid nitriding process, though plasma nitriding is preferred for high precision components. Various trials were conducted to optimize the process parameters, considering pre dimensional setting for nominal nitriding layer growth. Surface cleaning, suitable fixtures and stress relieving operations were also done to optimize the process. Micro structural analysis and Vickers hardness testing were carried out for analyzing the phase changes, variation in surface hardness and case depth. CNC gear testing machine was used for determining the distortion level. The presence of white layer was found for about 10-15μm in the case depth of 250± 3.5μm showing an average surface hardness of 670 HV. Hence the economical liquid nitriding process was successfully used for producing high hardness and wear resistant coating over 20MnCr5 material with less distortion and reduced secondary grinding process for dimensional control.

  13. Near-infrared free carrier absorption in heavily doped silicon

    International Nuclear Information System (INIS)

    Baker-Finch, Simeon C.; McIntosh, Keith R.; Yan, Di; Fong, Kean Chern; Kho, Teng C.

    2014-01-01

    Free carrier absorption in heavily doped silicon can have a significant impact on devices operating in the infrared. In the near infrared, the free carrier absorption process can compete with band to band absorption processes, thereby reducing the number of available photons to optoelectronic devices such as solar cells. In this work, we fabricate 18 heavily doped regions by phosphorus and boron diffusion into planar polished silicon wafers; the simple sample structure facilitates accurate and precise measurement of the free carrier absorptance. We measure and model reflectance and transmittance dispersion to arrive at a parameterisation for the free carrier absorption coefficient that applies in the wavelength range between 1000 and 1500 nm, and the range of dopant densities between ∼10 18 and 3 × 10 20  cm −3 . Our measurements indicate that previously published parameterisations underestimate the free carrier absorptance in phosphorus diffusions. On the other hand, published parameterisations are generally consistent with our measurements and model for boron diffusions. Our new model is the first to be assigned uncertainty and is well-suited to routine device analysis

  14. Practical controller design for ultra-precision positioning of stages with a pneumatic artificial muscle actuator

    Science.gov (United States)

    Tang, T. F.; Chong, S. H.

    2017-06-01

    This paper presents a practical controller design method for ultra-precision positioning of pneumatic artificial muscle actuator stages. Pneumatic artificial muscle (PAM) actuators are safe to use and have numerous advantages which have brought these actuators to wide applications. However, PAM exhibits strong non-linear characteristics, and these limitations lead to low controllability and limit its application. In practice, the non-linear characteristics of PAM mechanism are difficult to be precisely modeled, and time consuming to model them accurately. The purpose of the present study is to clarify a practical controller design method that emphasizes a simple design procedure that does not acquire plants parameters modeling, and yet is able to demonstrate ultra-precision positioning performance for a PAM driven stage. The practical control approach adopts continuous motion nominal characteristic trajectory following (CM NCTF) control as the feedback controller. The constructed PAM driven stage is in low damping characteristic and causes severe residual vibration that deteriorates motion accuracy of the system. Therefore, the idea to increase the damping characteristic by having an acceleration feedback compensation to the plant has been proposed. The effectiveness of the proposed controller was verified experimentally and compared with a classical PI controller in point-to-point motion. The experiment results proved that the CM NCTF controller demonstrates better positioning performance in smaller motion error than the PI controller. Overall, the CM NCTF controller has successfully to reduce motion error to 3µm, which is 88.7% smaller than the PI controller.

  15. Strong signatures of right-handed compositeness

    Energy Technology Data Exchange (ETDEWEB)

    Redi, Michele [INFN, Sesto Fiorentino, Firenze (Italy); Sanz, Veronica [York Univ., Toronto, ON (Canada). Dept. of Physics and Astronomy; Sussex Univ., Brighton (United Kingdom). Dept. of Physics and Astronomy; Vries, Maikel de; Weiler, Andreas [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2013-05-15

    Right-handed light quarks could be significantly composite, yet compatible with experimental searches at the LHC and precision tests on Standard Model couplings. In these scenarios, that are motivated by flavor physics, one expects large cross sections for the production of new resonances coupled to light quarks. We study experimental strong signatures of right-handed compositeness at the LHC, and constrain the parameter space of these models with recent results by ATLAS and CMS. We show that the LHC sensitivity could be significantly improved if dedicated searches were performed, in particular in multi-jet signals.

  16. Free-piston reciprocating cryogenic expander utilizing phase controller

    Science.gov (United States)

    Cha, Jeongmin; Park, Jiho; Kim, Kyungjoong; Jeong, Sangkwon

    2017-02-01

    In a free-piston expander which eliminates mechanical linkages, a prescribed behaviour of the free-piston movement is the key to an expander performance. In this paper, we have proposed an idea of reducing complexity of the free-piston expander. It is to replace both multiple solenoid valves and reservoirs that are indispensable in a previous machine with a combination of a single orifice-reservoir assembly. It functions as a phase controller like that of a pulse tube refrigerator so that it generates time-delay of pressure variation between the warm-end and the reservoir resulting in the intended expansion of the cold-end volume down to the pre-set reservoir pressure. The modeling of this unique free-piston reciprocating expander utilizing phase controller is developed to understand and predict the performance of the new-type expander. Additionally, the operating parameters are analysed at the specified conditions to enable one to develop a more efficient free-piston type cryogenic expander.

  17. Primary Coolant pH Control for Soluble Boron-Free PWRs

    International Nuclear Information System (INIS)

    Cheon, Yang Ho; Lee, Nam Yeong; Park, Byeong Ho; Park, Seong Chan; Kim, Eun Kee

    2015-01-01

    These should be considered when evaluating and designing the operating pH program for nuclear power plants. This paper discusses the advanced water chemistry strategies to keep pace with the recent global trends related to pH control in the primary water system for soluble boron pressurized water reactor (PWR) plants. Finally, the objective of this work is to study primary coolant pH control for soluble boron-free PWR plants. This paper reviewed the advanced water chemistry strategies to keep pace with the recent global trends related to pH control in the primary water chemistry system for soluble boron PWR plants. The new chemistry trend for the primary coolant is towards adaption of the constant and elevated chemistry. Finally, this work studied primary coolant pH control for soluble boron-free PWR plants. The ammonia-based water chemistry related to pH control for boron-free PWR plants was discussed. The ammonia-based water chemistry is not recommended to avoid fluctuation of the pH value by ammonia radiolysis and to reduce C-14 production in reactor coolant from reaction with dissolved nitrogen. Also, the potassium-based water chemistry related to pH control for boron-free PWR plants was discussed. KOH has a potential as an alternative pH control agent for soluble boron-free PWR plants. The potassium-based water chemistry related to pH control is recommended for boron-free operation as follows

  18. A Method for Precision Closed-Loop Irrigation Using a Modified PID Control Algorithm

    Science.gov (United States)

    Goodchild, Martin; Kühn, Karl; Jenkins, Malcolm; Burek, Kazimierz; Dutton, Andrew

    2016-04-01

    The benefits of closed-loop irrigation control have been demonstrated in grower trials which show the potential for improved crop yields and resource usage. Managing water use by controlling irrigation in response to soil moisture changes to meet crop water demands is a popular approach but requires knowledge of closed-loop control practice. In theory, to obtain precise closed-loop control of a system it is necessary to characterise every component in the control loop to derive the appropriate controller parameters, i.e. proportional, integral & derivative (PID) parameters in a classic PID controller. In practice this is often difficult to achieve. Empirical methods are employed to estimate the PID parameters by observing how the system performs under open-loop conditions. In this paper we present a modified PID controller, with a constrained integral function, that delivers excellent regulation of soil moisture by supplying the appropriate amount of water to meet the needs of the plant during the diurnal cycle. Furthermore, the modified PID controller responds quickly to changes in environmental conditions, including rainfall events which can result in: controller windup, under-watering and plant stress conditions. The experimental work successfully demonstrates the functionality of a constrained integral PID controller that delivers robust and precise irrigation control. Coir substrate strawberry growing trial data is also presented illustrating soil moisture control and the ability to match water deliver to solar radiation.

  19. Dynamics, control and sensor issues pertinent to robotic hands for the EVA retriever system

    Science.gov (United States)

    Mclauchlan, Robert A.

    1987-01-01

    Basic dynamics, sensor, control, and related artificial intelligence issues pertinent to smart robotic hands for the Extra Vehicular Activity (EVA) Retriever system are summarized and discussed. These smart hands are to be used as end effectors on arms attached to manned maneuvering units (MMU). The Retriever robotic systems comprised of MMU, arm and smart hands, are being developed to aid crewmen in the performance of routine EVA tasks including tool and object retrieval. The ultimate goal is to enhance the effectiveness of EVA crewmen.

  20. New portable hand-held radiation instruments for measurements and monitoring

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1987-01-01

    Hand-held radiation monitors are often used to search pedestrians and motor vehicles for special nuclear material (SNM) as part of a physical protection plan for nuclear materials. Recently, the Los Alamos Advanced Nuclear Technology group has commercialized an improved hand-held monitor that can be used for both physical-protection monitoring and verification measurements in nuclear material control and waste management. The new monitoring instruments are smaller and lighter; operate much longer on a battery charge; are available with NaI(Tl) or neutron and gamma-ray sensitive plastic scintillation detectors; and are less expensive than other comparable instruments. They also have a second operating mode for making precise measurements over counting times as long as 99 s. This mode permits making basic verification measurements that may be needed before transporting nuclear material or waste outside protected areas. Improved verification measurements can be made with a second new hand-held instrument that has a stabilized detector and three separate gamma-ray energy windows to obtain spectral information for SNM quantity, enrichment, or material-type verification

  1. The Design and Development of the Precision Planter Sowing Depth Control System

    Directory of Open Access Journals (Sweden)

    Liping WEN

    2014-01-01

    Full Text Available In view the accuracy requirements of sowing depth control for precision planter, we carried out the design and development of control system. This paper main includes the working principle of the control system, the hardware and software design of electro-hydraulic proportional control system. It also respectively explains the software programming of PLC, the software programming of touch screen. Practical application shows that this system has advantages of stable operation, high reliability, convenient operation and maintenance, with high promotion and use value.

  2. Strengthening and stretching for rheumatoid arthritis of the hand (SARAH: design of a randomised controlled trial of a hand and upper limb exercise intervention - ISRCTN89936343

    Directory of Open Access Journals (Sweden)

    Adams Jo

    2012-11-01

    Full Text Available Abstract Background Rheumatoid Arthritis (RA commonly affects the hands and wrists with inflammation, deformity, pain, weakness and restricted mobility leading to reduced function. The effectiveness of exercise for RA hands is uncertain, although evidence from small scale studies is promising. The Strengthening And Stretching for Rheumatoid Arthritis of the Hand (SARAH trial is a pragmatic, multi-centre randomised controlled trial evaluating the clinical and cost effectiveness of adding an optimised exercise programme for hands and upper limbs to best practice usual care for patients with RA. Methods/design 480 participants with problematic RA hands will be recruited through 17 NHS trusts. Treatments will be provided by physiotherapists and occupational therapists. Participants will be individually randomised to receive either best practice usual care (joint protection advice, general exercise advice, functional splinting and assistive devices or best practice usual care supplemented with an individualised exercise programme of strengthening and stretching exercises. The study assessors will be blinded to treatment allocation and will follow participants up at four and 12 months. The primary outcome measure is the Hand function subscale of the Michigan Hand Outcome Questionnaire, and secondary outcomes include hand and wrist impairment measures, quality of life, and resource use. Economic and qualitative studies will also be carried out in parallel. Discussion This paper describes the design and development of a trial protocol of a complex intervention study based in therapy out-patient departments. The findings will provide evidence to support or refute the use of an optimised exercise programme for RA of the hand in addition to best practice usual care. Trial registration Current Controlled Trials ISRCTN89936343

  3. Efficacy of the Precise Climate Controller on the reduction of indoor microorganisms

    OpenAIRE

    Moungthong, Greetha; Klamkam, Pana; Mahakit, Prasit; Chalermwatanachai, Thanit; Thunyaharn, Sudaluck; Monyakul, Veerapol

    2014-01-01

    Background Nowadays, there are many methods to reduce microorganisms in the air, such as dehumidifier, air purifier or humidity and temperature controller. The Precise Climate Controller is an instrument for controlling humidity and temperature, a concept that is demonstrated. Objective To determine the efficacy of this device, in order to reduce the quantity of the fungi and bacteria in the closed system. Methods This study is a perspective experimental study and is conducted as follows - th...

  4. Effect of clinical parameters on the control of myoelectric robotic prosthetic hands.

    Science.gov (United States)

    Atzori, Manfredo; Gijsberts, Arjan; Castellini, Claudio; Caputo, Barbara; Hager, Anne-Gabrielle Mittaz; Elsig, Simone; Giatsidis, Giorgio; Bassetto, Franco; Müller, Henning

    2016-01-01

    Improving the functionality of prosthetic hands with noninvasive techniques is still a challenge. Surface electromyography (sEMG) currently gives limited control capabilities; however, the application of machine learning to the analysis of sEMG signals is promising and has recently been applied in practice, but many questions still remain. In this study, we recorded the sEMG activity of the forearm of 11 male subjects with transradial amputation who were mentally performing 40 hand and wrist movements. The classification performance and the number of independent movements (defined as the subset of movements that could be distinguished with >90% accuracy) were studied in relationship to clinical parameters related to the amputation. The analysis showed that classification accuracy and the number of independent movements increased significantly with phantom limb sensation intensity, remaining forearm percentage, and temporal distance to the amputation. The classification results suggest the possibility of naturally controlling up to 11 movements of a robotic prosthetic hand with almost no training. Knowledge of the relationship between classification accuracy and clinical parameters adds new information regarding the nature of phantom limb pain as well as other clinical parameters, and it can lay the foundations for future "functional amputation" procedures in surgery.

  5. Altered brain functions in HIV positive patients free of HIV- associated neurocognitive disorders: A MRI study during unilateral hand movements

    Directory of Open Access Journals (Sweden)

    Jing Zhao

    2015-03-01

    Full Text Available This paper aimed to investigate the brain activity of human immunodeficiency virus (HIV positive patients with normal cognition during unilateral hand movement and whether highly active antiretroviral therapy (HAART could affect the brain function. Functional magnetic resonance imaging (fMRI was performed for 60 HIV positive (HIV+ subjects and −42 healthy age-matched right-handed control subjects. Each subject was evaluated by the neuropsychological test and examined with fMRI during left and right hand movement tasks. HIV+ subjects showed greater activation in anterior cingulum, precuneus, occipital lobes, ipsilateral postcentral gyrus and contralateral cerebellum compared with control group during right hand movement task. However, during left hand movement no statistically significant difference was detected between these two groups. HAART medication for HIV+ subjects lowered the increased activity to normal level. Meanwhile patients receiving the regimen of zidovudine, lamivudine and efavirenz showed lower activity at bilateral caudate and ipsilateral inferior frontal gyrus in comparison with subjects receiving other HAART regimens. Therefore, HIV+ subjects demonstrated brain asymmetry in motor cortex, with increased activity present during right hand movement but absent during left hand movement. HAART proves effective in HIV+ subjects even with normal cognition and the specific regimen of HAART could prevent cerebral abnormal functions. Meanwhile, this study validates that during motor tasks, fMRI can detect the brain signal changes prior to the occurrences of other HIV- associated dysfunctions.

  6. Precision and accuracy, two steps towards the standardization of XRPD measurements

    International Nuclear Information System (INIS)

    Berti, G.

    1996-01-01

    Any standardization process requires to get at results comprehensible, reproducible and traceable. Precision and accuracy of the measurements play a key role in getting at these requirements. The adoption of either physical (standard) or mathematical models allows for describing the whole diffraction measurement process with the necessary physical significance. From an other hand, the adoption of procedure, which are capable of controlling the measurement process, renders it reproducible and traceable. The falling of those requirements make difficult to transfer or replicate elsewhere experiences which may give even excellent result in a given laboratory

  7. Precision and accuracy, two steps towards the standardization of XRPD measurements

    Energy Technology Data Exchange (ETDEWEB)

    Berti, G [Pisa Univ. (Italy). Dept. of Earth Sciences

    1996-09-01

    Any standardization process requires to get at results comprehensible, reproducible and traceable. Precision and accuracy of the measurements play a key role in getting at these requirements. The adoption of either physical (standard) or mathematical models allows for describing the whole diffraction measurement process with the necessary physical significance. From an other hand, the adoption of procedure, which are capable of controlling the measurement process, renders it reproducible and traceable. The falling of those requirements make difficult to transfer or replicate elsewhere experiences which may give even excellent result in a given laboratory.

  8. Control system for JAERI Free Electron Laser

    International Nuclear Information System (INIS)

    Sugimoto, Masayoshi

    1992-01-01

    A control system comprising of the personal computers network and the CAMAC stations for the JAERI Free Electron Laser is designed and is in the development stage. It controls the equipment and analyzes the electron and optical beam experiments. The concept and the prototype of the control system are described. (author)

  9. Controlling cell-free metabolism through physiochemical perturbations.

    Science.gov (United States)

    Karim, Ashty S; Heggestad, Jacob T; Crowe, Samantha A; Jewett, Michael C

    2018-01-01

    Building biosynthetic pathways and engineering metabolic reactions in cells can be time-consuming due to complexities in cellular metabolism. These complexities often convolute the combinatorial testing of biosynthetic pathway designs needed to define an optimal biosynthetic system. To simplify the optimization of biosynthetic systems, we recently reported a new cell-free framework for pathway construction and testing. In this framework, multiple crude-cell extracts are selectively enriched with individual pathway enzymes, which are then mixed to construct full biosynthetic pathways on the time scale of a day. This rapid approach to building pathways aids in the study of metabolic pathway performance by providing a unique freedom of design to modify and control biological systems for both fundamental and applied biotechnology. The goal of this work was to demonstrate the ability to probe biosynthetic pathway performance in our cell-free framework by perturbing physiochemical conditions, using n-butanol synthesis as a model. We carried out three unique case studies. First, we demonstrated the power of our cell-free approach to maximize biosynthesis yields by mapping physiochemical landscapes using a robotic liquid-handler. This allowed us to determine that NAD and CoA are the most important factors that govern cell-free n-butanol metabolism. Second, we compared metabolic profile differences between two different approaches for building pathways from enriched lysates, heterologous expression and cell-free protein synthesis. We discover that phosphate from PEP utilization, along with other physiochemical reagents, during cell-free protein synthesis-coupled, crude-lysate metabolic system operation inhibits optimal cell-free n-butanol metabolism. Third, we show that non-phosphorylated secondary energy substrates can be used to fuel cell-free protein synthesis and n-butanol biosynthesis. Taken together, our work highlights the ease of using cell-free systems to explore

  10. Quantitative Assessment of the Arm/Hand Movements in Parkinson’s Disease Using a Wireless Armband Device

    Directory of Open Access Journals (Sweden)

    Sofija Spasojević

    2017-08-01

    Full Text Available We present an approach for quantitative assessment of the arm/hand movements in patients with Parkinson’s disease (PD, from sensor data acquired with a wearable, wireless armband device (Myo sensor. We propose new Movement Performance Indicators that can be adopted by practitioners for the quantitative evaluation of motor performance and support their clinical evaluations. In addition, specific Movement Performance Indicators can indicate the presence of the bradykinesia symptom. The study includes seventeen PD patients and sixteen age-matched controls. A set of representative arm/hand movements is defined under the supervision of movement disorder specialist. In order to assist the evaluations, and for progress monitoring purposes, as well as for assessing the amount of bradykinesia in PD, a total set of 84 Movement Performance Indicators are computed from the sensor readings. Subsequently, we investigate whether wireless armband device, with the use of the proposed Movement Performance Indicators can be utilized: (1 for objective and precise quantitative evaluation of the arm/hand movements of Parkinson’s patients, (2 for assessment of the bradykinesia motor symptom, and (3 as an adequate low-cost alternative for the sensor glove. We conducted extensive analysis of proposed Movement Performance Indicators and results are indicating following clinically relevant characteristics: (i adequate reliability as measured by ICC; (ii high accuracy in discrimination between the patients and controls, and between the disease stages (support to disease diagnosis and progress monitoring, respectively; (iii substantial difference in comparison between the left-hand and the right-hand movements across controls and patients, as well as between disease stage groups; (iv statistically significant correlation with clinical scales (tapping test and UPDRS-III Motor Score; and (v quantitative evaluation of bradykinesia symptom. Results suggest that the proposed

  11. Micropropulsion Systems for Precision Controlled Space Flight

    DEFF Research Database (Denmark)

    Larsen, Jack

    . This project is thus concentrating on developing a method by which an entire, ecient, control system compensating for the disturbances from the space environment and thereby enabling precision formation flight can be realized. The space environment is initially studied and the knowledge gained is used......Space science is subject to a constantly increasing demand for larger coherence lengths or apertures of the space observation systems, which in turn translates into a demand for increased dimensions and subsequently cost and complexity of the systems. When this increasing demand reaches...... the pratical limitations of increasing the physical dimensions of the spacecrafts, the observation platforms will have to be distributed on more spacecrafts flying in very accurate formations. Consequently, the observation platform becomes much more sensitive to disturbances from the space environment...

  12. Neuro-prosthetic interplay. Comment on "Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands" by M. Santello et al.

    Science.gov (United States)

    Schieber, Marc H.

    2016-07-01

    Control of the human hand has been both difficult to understand scientifically and difficult to emulate technologically. The article by Santello and colleagues in the current issue of Physics of Life Reviews[1] highlights the accelerating pace of interaction between the neuroscience of controlling body movement and the engineering of robotic hands that can be used either autonomously or as part of a motor neuroprosthesis, an artificial body part that moves under control from a human subject's own nervous system. Motor neuroprostheses typically involve a brain-computer interface (BCI) that takes signals from the subject's nervous system or muscles, interprets those signals through a decoding algorithm, and then applies the resulting output to control the artificial device.

  13. Weed Control in Soybean (Glycine max)

    International Nuclear Information System (INIS)

    Kipkemoi, P.L.

    2002-01-01

    Weed Compete for limited growth factors with crop plants. This result in loss of crop vigour and hence reduces crop yields. A study was conducted in 1997 and 2001 to evaluate the use of herbicides and hand hoeing for weed control in soybeans. Crop establishment was by hand planting. The herbicides were applied using CP3 Knap sack sprayer calibrated to deliver a spray volume of 150l/ha. Hand weeding treatment were done as appropriate. The trial layout was randomised complete block design with four replications in both years. The tested herbicides did not satisfactorily control the weeds present at the experimental site in both years. Hand weeding on the other hand gave good control of the weeds which were reflected in high soybean yields. In these trials yields were negatively correlated with the number of weeds present. The tested herbicides alone appeared to be inadequate in controlling weeds in soybean. Compared with the weed-free treatment a single application of soil-applied or post-emergence herbicides did not control a broad spectrum of weeds and reduced soybean yields. It can also be inferred that soybean yield losses are minimised if they are kept weed free for at most 6 weeks after emergence

  14. Working hard to make a simple definition of synergies. Comment on: "Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands" by Marco Santello et al.

    Science.gov (United States)

    Alessandro, Cristiano; Oliveira Barroso, Filipe; Tresch, Matthew

    2016-07-01

    The paper ;Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands; [1] presents a comprehensive review of the work carried out as part of the EU funded project ;The Hand Embodied;. The work uses the concept of ;synergy; to study the neuromuscular control of the human hand and to design novel robotics systems. The project has been very productive and has made important contributions. We are therefore confident that it will lead to further advancements and experiments in the future.

  15. Hand Hygiene With Alcohol-Based Hand Rub: How Long Is Long Enough?

    Science.gov (United States)

    Pires, Daniela; Soule, Hervé; Bellissimo-Rodrigues, Fernando; Gayet-Ageron, Angèle; Pittet, Didier

    2017-05-01

    BACKGROUND Hand hygiene is the core element of infection prevention and control. The optimal hand-hygiene gesture, however, remains poorly defined. OBJECTIVE We aimed to evaluate the influence of hand-rubbing duration on the reduction of bacterial counts on the hands of healthcare personnel (HCP). METHODS We performed an experimental study based on the European Norm 1500. Hand rubbing was performed for 10, 15, 20, 30, 45, or 60 seconds, according to the WHO technique using 3 mL alcohol-based hand rub. Hand contamination with E. coli ATCC 10536 was followed by hand rubbing and sampling. A generalized linear mixed model with a random effect on the subject adjusted for hand size and gender was used to analyze the reduction in bacterial counts after each hand-rubbing action. In addition, hand-rubbing durations of 15 and 30 seconds were compared to assert non-inferiority (0.6 log10). RESULTS In total, 32 HCP performed 123 trials. All durations of hand rubbing led to significant reductions in bacterial counts (Phand rubbing were not significantly different from those obtained after 30 seconds. The mean bacterial reduction after 15 seconds of hand rubbing was 0.11 log10 lower (95% CI, -0.46 to 0.24) than after 30 seconds, demonstrating non-inferiority. CONCLUSIONS Hand rubbing for 15 seconds was not inferior to 30 seconds in reducing bacterial counts on hands under the described experimental conditions. There was no gain in reducing bacterial counts from hand rubbing longer than 30 seconds. Further studies are needed to assess the clinical significance of our findings. Infect Control Hosp Epidemiol 2017;38:547-552.

  16. The left hand doesn't know what the right hand is doing: the disruptive effects of attention to the hands in skilled typewriting.

    Science.gov (United States)

    Logan, Gordon D; Crump, Matthew J C

    2009-10-01

    Everyone knows that attention to the details disrupts skilled performance, but little empirical evidence documents this fact. We show that attention to the hands disrupts skilled typewriting. We had skilled typists type words preceded by cues that told them to type only the letters assigned to one hand or to type all of the letters. Cuing the hands disrupted performance markedly, slowing typing and increasing the error rate (Experiment 1); these deleterious effects were observed even when no keystrokes were actually inhibited (Experiment 3). However, cuing the same letters with colors was not disruptive (Experiment 2). We account for the disruption with a hierarchical control model, in which an inner loop controls the hands and an outer loop controls what is typed. Typing letters using only one hand requires the outer loop to monitor the inner loop's output; the outer loop slows inner-loop cycle time to increase the likelihood of inhibiting responses with the unwanted hand. This produces the disruption.

  17. [Hand hygiene: first measure to control nosocomial infection].

    Science.gov (United States)

    Christiaens, G; Barbier, C; Mutsers, J; Warnotte, J; De Mol, P; Bouffioux, C

    2006-01-01

    Hand hygiene prevents cross infection in hospi tals, however adherence to guidelines is commonly poor. The hand-hygiene promotion programme started on May 2004 at the University Hospital of Liège after a baseline survey of compliance. We attempted to promote hand hygiene and most par ticularly alcohol-based hand disinfection. We measured MRSA transmission rates and consumption of alcohol-based handrub solution and soap in parallel. During the campaign, consump tion of alcohol-based handrub solution and soap increased by 56% and 24% respectively and MRSA transmission rates decreased from 11,04 to 7,07 cases per 1000 admissions.

  18. Active and Precise Control of Microdroplet Division Using Horizontal Pneumatic Valves in Bifurcating Microchannel

    Directory of Open Access Journals (Sweden)

    Shuichi Shoji

    2013-05-01

    Full Text Available This paper presents a microfluidic system for the active and precise control of microdroplet division in a micro device. Using two horizontal pneumatic valves formed at downstream of bifurcating microchannel, flow resistances of downstream channels were variably controlled. With the resistance control, volumetric ratio of downstream flows was changed and water-in-oil microdroplets were divided into two daughter droplets of different volume corresponding to the ratio. The microfluidic channels and pneumatic valves were fabricated by single-step soft lithography process of PDMS (polydimethylsiloxane using SU-8 mold. A wide range control of the daughter droplets’ volume ratio was achieved by the simple channel structure. Volumetric ratio between large and small daughter droplets are ranged from 1 to 70, and the smallest droplet volume of 14 pL was obtained. The proposed microfluidic device is applicable for precise and high throughput droplet based digital synthesis.

  19. From foraging to operant conditioning: a new computer-controlled Skinner box to study free-flying nectar gathering behavior in bees.

    Science.gov (United States)

    Sokolowski, Michel B C; Abramson, Charles I

    2010-05-15

    The experimental study of nectar foraging behavior in free-flying bees requires the use of automated devices to control solution delivery and measure dependent variables associated with nectar gathering. We describe a new computer-controlled artificial flower and provide calibration data to measure the precision of the apparatus. Our device is similar to a "Skinner box" and we present data of an experiment where various amounts of a 50% sugar solution are presented randomly to individual bees. These data show large individual variations among subjects across several dependent variables. Finally, we discuss possible applications of our device to problems in behavioral sciences. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  20. Design and control of precision drop-on-demand herbicide application in agricultural robotics

    OpenAIRE

    Urdal, Frode; Utstumo, Trygve; Vatne, Jan Kåre; Ellingsen, Simen Andreas Ådnøy; Gravdahl, Jan Tommy

    2014-01-01

    This is the author’s final, accepted and refereed manuscript to the article. Drop-on-demand weed control is a field of research within Precision Agriculture, where the herbicide application is controlled down to individual droplets. This paper focuses on the fluid dynamics and electronics design of the droplet dispensing. The droplets are formed through an array of nozzles, controlled by two-way solenoid valves. A much used control circuit for opening and closing a soleno...

  1. Illusory movement perception improves motor control for prosthetic hands.

    Science.gov (United States)

    Marasco, Paul D; Hebert, Jacqueline S; Sensinger, Jon W; Shell, Courtney E; Schofield, Jonathon S; Thumser, Zachary C; Nataraj, Raviraj; Beckler, Dylan T; Dawson, Michael R; Blustein, Dan H; Gill, Satinder; Mensh, Brett D; Granja-Vazquez, Rafael; Newcomb, Madeline D; Carey, Jason P; Orzell, Beth M

    2018-03-14

    To effortlessly complete an intentional movement, the brain needs feedback from the body regarding the movement's progress. This largely nonconscious kinesthetic sense helps the brain to learn relationships between motor commands and outcomes to correct movement errors. Prosthetic systems for restoring function have predominantly focused on controlling motorized joint movement. Without the kinesthetic sense, however, these devices do not become intuitively controllable. We report a method for endowing human amputees with a kinesthetic perception of dexterous robotic hands. Vibrating the muscles used for prosthetic control via a neural-machine interface produced the illusory perception of complex grip movements. Within minutes, three amputees integrated this kinesthetic feedback and improved movement control. Combining intent, kinesthesia, and vision instilled participants with a sense of agency over the robotic movements. This feedback approach for closed-loop control opens a pathway to seamless integration of minds and machines. Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  2. Depth camera-based 3D hand gesture controls with immersive tactile feedback for natural mid-air gesture interactions.

    Science.gov (United States)

    Kim, Kwangtaek; Kim, Joongrock; Choi, Jaesung; Kim, Junghyun; Lee, Sangyoun

    2015-01-08

    Vision-based hand gesture interactions are natural and intuitive when interacting with computers, since we naturally exploit gestures to communicate with other people. However, it is agreed that users suffer from discomfort and fatigue when using gesture-controlled interfaces, due to the lack of physical feedback. To solve the problem, we propose a novel complete solution of a hand gesture control system employing immersive tactile feedback to the user's hand. For this goal, we first developed a fast and accurate hand-tracking algorithm with a Kinect sensor using the proposed MLBP (modified local binary pattern) that can efficiently analyze 3D shapes in depth images. The superiority of our tracking method was verified in terms of tracking accuracy and speed by comparing with existing methods, Natural Interaction Technology for End-user (NITE), 3D Hand Tracker and CamShift. As the second step, a new tactile feedback technology with a piezoelectric actuator has been developed and integrated into the developed hand tracking algorithm, including the DTW (dynamic time warping) gesture recognition algorithm for a complete solution of an immersive gesture control system. The quantitative and qualitative evaluations of the integrated system were conducted with human subjects, and the results demonstrate that our gesture control with tactile feedback is a promising technology compared to a vision-based gesture control system that has typically no feedback for the user's gesture inputs. Our study provides researchers and designers with informative guidelines to develop more natural gesture control systems or immersive user interfaces with haptic feedback.

  3. Depth Camera-Based 3D Hand Gesture Controls with Immersive Tactile Feedback for Natural Mid-Air Gesture Interactions

    Directory of Open Access Journals (Sweden)

    Kwangtaek Kim

    2015-01-01

    Full Text Available Vision-based hand gesture interactions are natural and intuitive when interacting with computers, since we naturally exploit gestures to communicate with other people. However, it is agreed that users suffer from discomfort and fatigue when using gesture-controlled interfaces, due to the lack of physical feedback. To solve the problem, we propose a novel complete solution of a hand gesture control system employing immersive tactile feedback to the user’s hand. For this goal, we first developed a fast and accurate hand-tracking algorithm with a Kinect sensor using the proposed MLBP (modified local binary pattern that can efficiently analyze 3D shapes in depth images. The superiority of our tracking method was verified in terms of tracking accuracy and speed by comparing with existing methods, Natural Interaction Technology for End-user (NITE, 3D Hand Tracker and CamShift. As the second step, a new tactile feedback technology with a piezoelectric actuator has been developed and integrated into the developed hand tracking algorithm, including the DTW (dynamic time warping gesture recognition algorithm for a complete solution of an immersive gesture control system. The quantitative and qualitative evaluations of the integrated system were conducted with human subjects, and the results demonstrate that our gesture control with tactile feedback is a promising technology compared to a vision-based gesture control system that has typically no feedback for the user’s gesture inputs. Our study provides researchers and designers with informative guidelines to develop more natural gesture control systems or immersive user interfaces with haptic feedback.

  4. Economic Evaluation of a Multifaceted Implementation Strategy for the Prevention of Hand Eczema Among Healthcare Workers in Comparison with a Control Group: The Hands4U Study.

    Science.gov (United States)

    van der Meer, Esther W C; van Dongen, Johanna M; Boot, Cécile R L; van der Gulden, Joost W J; Bosmans, Judith E; Anema, Johannes R

    2016-05-01

    The aim of this study was to evaluate the cost-effectiveness of a multifaceted implementation strategy for the prevention of hand eczema in comparison with a control group among healthcare workers. A total of 48 departments (n=1,649) were randomly allocated to the implementation strategy or the control group. Data on hand eczema and costs were collected at baseline and every 3 months. Cost-effectiveness analyses were performed using linear multilevel analyses. The probability of the implementation strategy being cost-effective gradually increased with an increasing willingness-to-pay, to 0.84 at a ceiling ratio of €590,000 per person with hand eczema prevented (societal perspective). The implementation strategy appeared to be not cost-effective in comparison with the control group (societal perspective), nor was it cost-beneficial to the employer. However, this study had some methodological problems which should be taken into account when interpreting the results.

  5. Second-hand smoke in public spaces: how effective has partial smoke-free legislation been in Malaysia?

    Science.gov (United States)

    Abidin, Emilia Zainal; Hashim, Zailina; Semple, Sean

    2013-01-01

    This study was performed to gather data on second-hand smoke (SHS) concentrations in a range of public venues following the implementation of partial Smoke-Free Legislation in Malaysia in 2004. PM2.5 was measured as a marker of SHS levels in a total of 61 restaurants, entertainment centres, internet cafes and pubs in Kuala Lumpur, Malaysia. Under the current smoke-free laws smoking was prohibited in 42 of the 61 premises. Active smoking was observed in nearly one-third (n=12) of these. For premises where smoking was prohibited and no active smoking observed, the mean (standard deviation) indoor PM2.5 concentration was 33.4 (23.8) μg/m3 compared to 187.1 (135.1) μg/m3 in premises where smoking was observed The highest mean PM2.5 was observed in pubs [361.5 (199.3) μg/m3]. This study provides evidence of high levels of SHS across a range of hospitality venues, including about one-third of those where smoking is prohibited, despite 8 years of smoke-free legislation. Compliance with the legislation appeared to be particularly poor in entertainment centres and internet cafes. Workers and non-smoking patrons continue to be exposed to high concentrations of SHS within the hospitality industry in Malaysia and there is an urgent need for increased enforcement of existing legislation and consideration of more comprehensive laws to protect health.

  6. A real-time vision-based hand gesture interaction system for virtual EAST

    International Nuclear Information System (INIS)

    Wang, K.R.; Xiao, B.J.; Xia, J.Y.; Li, Dan; Luo, W.L.

    2016-01-01

    Highlights: • Hand gesture interaction is first introduced to EAST model interaction. • We can interact with EAST model by a bared hand and a web camera. • We can interact with EAST model with a distance to screen. • Interaction is free, direct and effective. - Abstract: The virtual Experimental Advanced Superconducting Tokamak device (VEAST) is a very complicated 3D model, to interact with which, the traditional interaction devices are limited and inefficient. However, with the development of human-computer interaction (HCI), the hand gesture interaction has become a much popular choice in recent years. In this paper, we propose a real-time vision-based hand gesture interaction system for VEAST. By using one web camera, we can use our bare hand to interact with VEAST at a certain distance, which proves to be more efficient and direct than mouse. The system is composed of four modules: initialization, hand gesture recognition, interaction control and system settings. The hand gesture recognition method is based on codebook (CB) background modeling and open finger counting. Firstly, we build a background model with CB algorithm. Then, we segment the hand region by detecting skin color regions with “elliptical boundary model” in CbCr flat of YCbCr color space. Open finger which is used as a key feature of gesture can be tracked by an improved curvature-based method. Based on the method, we define nine gestures for interaction control of VEAST. Finally, we design a test to demonstrate effectiveness of our system.

  7. A real-time vision-based hand gesture interaction system for virtual EAST

    Energy Technology Data Exchange (ETDEWEB)

    Wang, K.R., E-mail: wangkr@mail.ustc.edu.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); University of Science and Technology of China, Hefei, Anhui (China); Xiao, B.J.; Xia, J.Y. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); University of Science and Technology of China, Hefei, Anhui (China); Li, Dan [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Luo, W.L. [709th Research Institute, Shipbuilding Industry Corporation (China)

    2016-11-15

    Highlights: • Hand gesture interaction is first introduced to EAST model interaction. • We can interact with EAST model by a bared hand and a web camera. • We can interact with EAST model with a distance to screen. • Interaction is free, direct and effective. - Abstract: The virtual Experimental Advanced Superconducting Tokamak device (VEAST) is a very complicated 3D model, to interact with which, the traditional interaction devices are limited and inefficient. However, with the development of human-computer interaction (HCI), the hand gesture interaction has become a much popular choice in recent years. In this paper, we propose a real-time vision-based hand gesture interaction system for VEAST. By using one web camera, we can use our bare hand to interact with VEAST at a certain distance, which proves to be more efficient and direct than mouse. The system is composed of four modules: initialization, hand gesture recognition, interaction control and system settings. The hand gesture recognition method is based on codebook (CB) background modeling and open finger counting. Firstly, we build a background model with CB algorithm. Then, we segment the hand region by detecting skin color regions with “elliptical boundary model” in CbCr flat of YCbCr color space. Open finger which is used as a key feature of gesture can be tracked by an improved curvature-based method. Based on the method, we define nine gestures for interaction control of VEAST. Finally, we design a test to demonstrate effectiveness of our system.

  8. Universal Robot Hand Equipped with Tactile and Joint Torque Sensors: Development and Experiments on Stiffness Control and Object Recognition

    Directory of Open Access Journals (Sweden)

    Hiroyuki NAKAMOTO

    2007-04-01

    Full Text Available Various humanoid robots have been developed and multifunction robot hands which are able to attach those robots like human hand is needed. But a useful robot hand has not been depeveloped, because there are a lot of problems such as control method of many degrees of freedom and processing method of enormous sensor outputs. Realizing such robot hand, we have developed five-finger robot hand. In this paper, the detailed structure of developed robot hand is described. The robot hand we developed has five fingers of multi-joint that is equipped with joint torque sensors and tactile sensors. We report experimental results of a stiffness control with the developed robot hand. Those results show that it is possible to change the stiffness of joints. Moreover we propose an object recognition method with the tactile sensor. The validity of that method is assured by experimental results.

  9. Recognizing the Operating Hand and the Hand-Changing Process for User Interface Adjustment on Smartphones.

    Science.gov (United States)

    Guo, Hansong; Huang, He; Huang, Liusheng; Sun, Yu-E

    2016-08-20

    As the size of smartphone touchscreens has become larger and larger in recent years, operability with a single hand is getting worse, especially for female users. We envision that user experience can be significantly improved if smartphones are able to recognize the current operating hand, detect the hand-changing process and then adjust the user interfaces subsequently. In this paper, we proposed, implemented and evaluated two novel systems. The first one leverages the user-generated touchscreen traces to recognize the current operating hand, and the second one utilizes the accelerometer and gyroscope data of all kinds of activities in the user's daily life to detect the hand-changing process. These two systems are based on two supervised classifiers constructed from a series of refined touchscreen trace, accelerometer and gyroscope features. As opposed to existing solutions that all require users to select the current operating hand or confirm the hand-changing process manually, our systems follow much more convenient and practical methods and allow users to change the operating hand frequently without any harm to the user experience. We conduct extensive experiments on Samsung Galaxy S4 smartphones, and the evaluation results demonstrate that our proposed systems can recognize the current operating hand and detect the hand-changing process with 94.1% and 93.9% precision and 94.1% and 93.7% True Positive Rates (TPR) respectively, when deciding with a single touchscreen trace or accelerometer-gyroscope data segment, and the False Positive Rates (FPR) are as low as 2.6% and 0.7% accordingly. These two systems can either work completely independently and achieve pretty high accuracies or work jointly to further improve the recognition accuracy.

  10. Real-Time Control System for Improved Precision and Throughput in an Ultrafast Carbon Fiber Placement Robot Using a SoC FPGA Extended Processing Platform

    Directory of Open Access Journals (Sweden)

    Gilberto Ochoa-Ruiz

    2017-01-01

    Full Text Available We present an architecture for accelerating the processing and execution of control commands in an ultrafast fiber placement robot. The system consists of a robotic arm designed by Coriolis Composites whose purpose is to move along a surface, on which composite fibers are deposed, via an independently controlled head. In first system implementation, the control commands were sent via Profibus by a PLC, limiting the reaction time and thus the precision of the fiber placement and the maximum throughput. Therefore, a custom real-time solution was imperative in order to ameliorate the performance and to meet the stringent requirements of the target industry (avionics, aeronautical systems. The solution presented in this paper is based on the use of a SoC FPGA processing platform running a real-time operating system (FreeRTOS, which has enabled an improved comamnd retrieval mechanism. The system’s placement precision was improved by a factor of 20 (from 1 mm to 0.05 mm, while the maximum achievable throughput was 1 m/s, compared to the average 30 cm/s provided by the original solution, enabling fabricating more complex and larger pieces in a significant fraction of the time.

  11. Multi-sensor control for precise assembly of optical components

    Directory of Open Access Journals (Sweden)

    Ma Li

    2014-06-01

    Full Text Available In order to perform an optical assembly accurately, a multi-sensor control strategy is developed which includes an attitude measurement system, a vision system, a loss measurement system and a force sensor. A 3-DOF attitude measuring method using linear variable differential transformers (LVDT is designed to adjust the relation of position and attitude between the spherical mirror and the resonator. A micro vision feedback system is set up to extract the light beam and the diaphragm, which can achieve the coarse positioning of the spherical mirror in the optical assembly process. A rapid self-correlation method is presented to analyze the spectrum signal for the fine positioning. In order to prevent the damage of the optical components and realize sealing of the resonator, a hybrid force-position control is constructed to control the contact force of the optical components. The experimental results show that the proposed multi-sensor control strategy succeeds in accomplishing the precise assembly of the optical components, which consists of parallel adjustment, macro coarse adjustment, macro approach, micro fine adjustment, micro approach and optical contact. Therefore, the results validate the multi-sensor control strategy.

  12. Precise Modeling Based on Dynamic Phasors for Droop-Controlled Parallel-Connected Inverters

    DEFF Research Database (Denmark)

    Wang, L.; Guo, X.Q.; Gu, H.R.

    2012-01-01

    This paper deals with the precise modeling of droop controlled parallel inverters. This is very attractive since that is a common structure that can be found in a stand-alone droopcontrolled MicroGrid. The conventional small-signal dynamic is not able to predict instabilities of the system, so...

  13. Stable Myoelectric Control of a Hand Prosthesis using Non-Linear Incremental Learning

    Directory of Open Access Journals (Sweden)

    Arjan eGijsberts

    2014-02-01

    Full Text Available Stable myoelectric control of hand prostheses remains an open problem. The only successful human-machine interface is surface electromyography, typically allowing control of a few degrees of freedom. Machine learning techniques may have the potential to remove these limitations, but their performance is thus far inadequate: myoelectric signals change over time under the influence of various factors, deteriorating control performance. It is therefore necessary, in the standard approach, to regularly retrain a new model from scratch.We hereby propose a non-linear incremental learning method in which occasional updates with a modest amount of novel training data allow continual adaptation to the changes in the signals. In particular, Incremental Ridge Regression and an approximation of the Gaussian Kernel known as Random Fourier Features are combined to predict finger forces from myoelectric signals, both finger-by-finger and grouped in grasping patterns.We show that the approach is effective and practically applicable to this problem by first analyzing its performance while predicting single-finger forces. Surface electromyography and finger forces were collected from 10 intact subjects during four sessions spread over two different days; the results of the analysis show that small incremental updates are indeed effective to maintain a stable level of performance.Subsequently, we employed the same method on-line to teleoperate a humanoid robotic arm equipped with a state-of-the-art commercial prosthetic hand. The subject could reliably grasp, carry and release everyday-life objects, enforcing stable grasping irrespective of the signal changes, hand/arm movements and wrist pronation and supination.

  14. Surface EMG in advanced hand prosthetics.

    Science.gov (United States)

    Castellini, Claudio; van der Smagt, Patrick

    2009-01-01

    One of the major problems when dealing with highly dexterous, active hand prostheses is their control by the patient wearing them. With the advances in mechatronics, building prosthetic hands with multiple active degrees of freedom is realisable, but actively controlling the position and especially the exerted force of each finger cannot yet be done naturally. This paper deals with advanced robotic hand control via surface electromyography. Building upon recent results, we show that machine learning, together with a simple downsampling algorithm, can be effectively used to control on-line, in real time, finger position as well as finger force of a highly dexterous robotic hand. The system determines the type of grasp a human subject is willing to use, and the required amount of force involved, with a high degree of accuracy. This represents a remarkable improvement with respect to the state-of-the-art of feed-forward control of dexterous mechanical hands, and opens up a scenario in which amputees will be able to control hand prostheses in a much finer way than it has so far been possible.

  15. The Ninapro database: A resource for sEMG naturally controlled robotic hand prosthetics.

    Science.gov (United States)

    Atzori, Manfredo; Muller, Henning

    2015-01-01

    The dexterous natural control of robotic prosthetic hands with non-invasive techniques is still a challenge: surface electromyography gives some control capabilities but these are limited, often not natural and require long training times; the application of pattern recognition techniques recently started to be applied in practice. While results in the scientific literature are promising they have to be improved to reach the real needs. The Ninapro database aims to improve the field of naturally controlled robotic hand prosthetics by permitting to worldwide research groups to develop and test movement recognition and force control algorithms on a benchmark database. Currently, the Ninapro database includes data from 67 intact subjects and 11 amputated subject performing approximately 50 different movements. The data are aimed at permitting the study of the relationships between surface electromyography, kinematics and dynamics. The Ninapro acquisition protocol was created in order to be easy to be reproduced. Currently, the number of datasets included in the database is increasing thanks to the collaboration of several research groups.

  16. Utilization of special computerized tomography and nuclear medicine techniques for quality control and for the optimization of combined precision chemotherapy and precision radiation therapy

    International Nuclear Information System (INIS)

    Wiley, A.L. Jr.; Wirtanen, G.W.; Chien, I.-C.

    1984-01-01

    A combination of precision (selective, intra-arterial) chemotherapy and precision radiotherapy can be used for advanced pancreatic, biliary tract, and sarcomatous malignancies. There were some remarkable responses, but also a few poor responses and even some morbidity. Accordingly, methods are developed of pre-selecting those patients whose tumors are likely to respond to such therapy, as well as methods for improving the therapeutic ratio by the rational optimization of combined therapy. Specifically, clinical tumor blood flow characteristics (monitored with nuclear medicine techniques) may provide useful criteria for such selection. The authors also evaluate qualitatively the drug distribution or exposure space with specialized color-coded computerized tomography images, which demonstrate spatially dependent enhancement of intra-arterial contrast in tumor and in adjacent normal tissues. Such clinical data can improve the quality control aspects of intra-arterial chemotherapy administration, as well as the possibility of achievement of a significant therapeutic ratio by the integration of precision chemotherapy and precision radiation therapy. (Auth.)

  17. Randomized Controlled Trial of Antiseptic Hand Hygiene Methods in an Outpatient Surgery Clinic.

    Science.gov (United States)

    Therattil, Paul J; Yueh, Janet H; Kordahi, Anthony M; Cherla, Deepa V; Lee, Edward S; Granick, Mark S

    2015-12-01

    Outpatient wound care plays an integral part in any plastic surgery practice. However, compliance with hand hygiene measures has shown to be low, due to skin irritation and lack of time. The objective of this trial was to determine whether single-use, long-acting antiseptics can be as effective as standard multiple-use hand hygiene methods in an outpatient surgical setting. A prospective, randomized controlled trial was performed in the authors' outpatient plastic surgery clinic at Rutgers New Jersey Medical School, Newark, NJ to compare the efficacy of an ethyl alcohol-based sanitizer (Avagard D Instant Hand Aniseptic, 3M Health Care, St. Paul, MN), a benzalkonium chloride-based sanitizer (Soft & Shield, Bioderm Technologies, Inc, Trenton, NJ, distributed by NAPP Technologies, Hackensack, NJ ), and soap and- water handwashing. Subjects included clinic personnel, who were followed throughout the course of a 3-hour clinic session with hourly hand bacterial counts taken. During the course of the trial, 95 subjects completed the clinic session utilizing 1 of the hand hygiene methods (36 ethyl alcohol-based sanitizer, 38 benzalkonium chloride-based sanitizer, and 21 soap-and-water handwashing). There was no difference between hand bacterial counts using the different methods at 4 hourly time points (P greater than 0.05). Hand bacterial counts increased significantly over the 3-hour clinic session with the ethyl alcohol-based sanitizer (9.24 to 21.90 CFU, P less than 0.05), benzalkonium chloride-based sanitizer (6.69 to 21.59 CFU, P less than 0.05), and soap-and-water handwashing (8.43 to 22.75 CFU, P less than 0.05). There does not appear to be any difference in efficacy between single-use, long-acting sanitizer, and standard multiple-use hand hygiene methods. Hand bacterial counts increased significantly over the course of the 3-hour clinic session regardless of the hand hygiene measure used. Hand condition of subjects was improved with the ethyl alcohol

  18. Precision control of recombinant gene transcription for CHO cell synthetic biology.

    Science.gov (United States)

    Brown, Adam J; James, David C

    2016-01-01

    The next generation of mammalian cell factories for biopharmaceutical production will be genetically engineered to possess both generic and product-specific manufacturing capabilities that may not exist naturally. Introduction of entirely new combinations of synthetic functions (e.g. novel metabolic or stress-response pathways), and retro-engineering of existing functional cell modules will drive disruptive change in cellular manufacturing performance. However, before we can apply the core concepts underpinning synthetic biology (design, build, test) to CHO cell engineering we must first develop practical and robust enabling technologies. Fundamentally, we will require the ability to precisely control the relative stoichiometry of numerous functional components we simultaneously introduce into the host cell factory. In this review we discuss how this can be achieved by design of engineered promoters that enable concerted control of recombinant gene transcription. We describe the specific mechanisms of transcriptional regulation that affect promoter function during bioproduction processes, and detail the highly-specific promoter design criteria that are required in the context of CHO cell engineering. The relative applicability of diverse promoter development strategies are discussed, including re-engineering of natural sequences, design of synthetic transcription factor-based systems, and construction of synthetic promoters. This review highlights the potential of promoter engineering to achieve precision transcriptional control for CHO cell synthetic biology. Copyright © 2015. Published by Elsevier Inc.

  19. ‎ Late Recovery from Stuttering: The Role of Hand ‎Dominancy, Fine Motor and ‎Inhibition Control

    Directory of Open Access Journals (Sweden)

    Hiwa Mohammadi

    2016-02-01

    Full Text Available Objective: There are controversial reports about factors that affect recovery from stuttering. In the ‎present study, the effect of hand dominancy, fine motor and inhibition control on late ‎recovery from stuttering was investigated among a group of Kurdish-Persian children who ‎stuttered in Iran.‎Method: Twenty-two Kurdish-Persian children aged 7-14 years who stuttered were followed for 6 ‎years. Based on the evaluation of three experienced speech therapists and parental judgments, ‎these children were classified into recovered or persistent groups. Data about fine motor ‎control of hand and inhibition control were obtained, using Purdue Pegboard and Victoria ‎Strop Color Word Tests, respectively. Risk factors including sex, age, and family history of ‎stuttering, handedness, inhibitory control and fine motor control of hand were compared ‎between the groups and modeled to predict recovery from stuttering using logistic regression.‎Results: From the 22 participants, 5 (22.7% recovered from stuttering. The recovered and persistent ‎groups did not show significant differences in the interference effect. By dividing the scores ‎of the Purdue Pegboard tests to the right and left hand, we created a new Handedness Index ‎‎(HI. HI was significantly higher in the recovered group. The score of right hand was higher ‎than the left in the recovered group, but no difference was found between the two hands in ‎the persistent group. Among the investigated risk factors, only HI could predict the recovery ‎from or persistency of stuttering with 94% sensitivity and 84% specificity.‎Conclusion: Handedness Index can predict the recovery from stuttering significantly among children who ‎stutter.‎

  20. An introduction about precise measurements of QED γ structure functions

    International Nuclear Information System (INIS)

    Courau, A.

    1989-11-01

    Pure QED processes are theoretically exactly computable. However precise measurements and theoretical expectations of QED γ structure functions within a given experimental acceptance are not so trivial. Yet such a study is quite interesting. It supplies on the one hand a good QED test and, on the other hand, a good exercise for testing the procedure used for the determination of the hadronic γ structure functions

  1. Control of free-flying space robot manipulator systems

    Science.gov (United States)

    Cannon, Robert H., Jr.

    1989-01-01

    Control techniques for self-contained, autonomous free-flying space robots are being tested and developed. Free-flying space robots are envisioned as a key element of any successful long term presence in space. These robots must be capable of performing the assembly, maintenance, and inspection, and repair tasks that currently require astronaut extra-vehicular activity (EVA). Use of robots will provide economic savings as well as improved astronaut safety by reducing and in many cases, eliminating the need for human EVA. The focus of the work is to develop and carry out a set of research projects using laboratory models of satellite robots. These devices use air-cushion-vehicle (ACV) technology to simulate in two dimensions the drag-free, zero-g conditions of space. Current work is divided into six major projects or research areas. Fixed-base cooperative manipulation work represents our initial entry into multiple arm cooperation and high-level control with a sophisticated user interface. The floating-base cooperative manipulation project strives to transfer some of the technologies developed in the fixed-base work onto a floating base. The global control and navigation experiment seeks to demonstrate simultaneous control of the robot manipulators and the robot base position so that tasks can be accomplished while the base is undergoing a controlled motion. The multiple-vehicle cooperation project's goal is to demonstrate multiple free-floating robots working in teams to carry out tasks too difficult or complex for a single robot to perform. The Location Enhancement Arm Push-off (LEAP) activity's goal is to provide a viable alternative to expendable gas thrusters for vehicle propulsion wherein the robot uses its manipulators to throw itself from place to place. Because the successful execution of the LEAP technique requires an accurate model of the robot and payload mass properties, it was deemed an attractive testbed for adaptive control technology.

  2. Plasma luminescence feedback control system for precise ultrashort pulse laser tissue ablation

    Science.gov (United States)

    Kim, Beop-Min; Feit, Michael D.; Rubenchik, Alexander M.; Gold, David M.; Darrow, Christopher B.; Marion, John E., II; Da Silva, Luiz B.

    1998-05-01

    Plasma luminescence spectroscopy was used for precise ablation of bone tissue without damaging nearby soft tissue using an ultrashort pulse laser. Strong contrast of the luminescence spectra between bone marrow and spinal cord provided the real time feedback control so bone tissue is selectively ablated while preserving the spinal cord.

  3. Modeling and control of an anthropomorphic robotic hand

    OpenAIRE

    Bensalah, Choukri

    2016-01-01

    Mención Europea en el título de doctor This thesis presents methods and tools for enabling the successful use of robotic hands. For highly dexterous and/or anthropomorphic robotic hands, these methods have to share some common goals, such as overcoming the potential complexity of the mechanical design and the ability of performing accurate tasks with low and efficient computational cost. A prerequisite for dexterity is to increase the workspace of the robotic hand. For th...

  4. A Scalable Weight-Free Learning Algorithm for Regulatory Control of Cell Activity in Spiking Neuronal Networks.

    Science.gov (United States)

    Zhang, Xu; Foderaro, Greg; Henriquez, Craig; Ferrari, Silvia

    2018-03-01

    Recent developments in neural stimulation and recording technologies are providing scientists with the ability of recording and controlling the activity of individual neurons in vitro or in vivo, with very high spatial and temporal resolution. Tools such as optogenetics, for example, are having a significant impact in the neuroscience field by delivering optical firing control with the precision and spatiotemporal resolution required for investigating information processing and plasticity in biological brains. While a number of training algorithms have been developed to date for spiking neural network (SNN) models of biological neuronal circuits, exiting methods rely on learning rules that adjust the synaptic strengths (or weights) directly, in order to obtain the desired network-level (or functional-level) performance. As such, they are not applicable to modifying plasticity in biological neuronal circuits, in which synaptic strengths only change as a result of pre- and post-synaptic neuron firings or biological mechanisms beyond our control. This paper presents a weight-free training algorithm that relies solely on adjusting the spatiotemporal delivery of neuron firings in order to optimize the network performance. The proposed weight-free algorithm does not require any knowledge of the SNN model or its plasticity mechanisms. As a result, this training approach is potentially realizable in vitro or in vivo via neural stimulation and recording technologies, such as optogenetics and multielectrode arrays, and could be utilized to control plasticity at multiple scales of biological neuronal circuits. The approach is demonstrated by training SNNs with hundreds of units to control a virtual insect navigating in an unknown environment.

  5. Inexpensive and Time-Efficient Hand Hygiene Interventions Increase Elementary School Children's Hand Hygiene Rates

    Science.gov (United States)

    Snow, Michelle; White, George L.; Kim, Han S.

    2008-01-01

    Routine hand hygiene has been cited by the World Health Organization and the Centers for Disease Control and Prevention as a cost-effective and important hygiene measure in preventing the spread of infectious diseases. Several studies have explored children's hand hygiene habits, effects of scheduled hand hygiene, hand hygiene environmental…

  6. Ability of Hand Hygiene Interventions Using Alcohol-Based Hand Sanitizers and Soap To Reduce Microbial Load on Farmworker Hands Soiled during Harvest.

    Science.gov (United States)

    de Aceituno, Anna Fabiszewski; Bartz, Faith E; Hodge, Domonique Watson; Shumaker, David J; Grubb, James E; Arbogast, James W; Dávila-Aviña, Jorgé; Venegas, Fabiola; Heredia, Norma; García, Santos; Leon, Juan S

    2015-11-01

    Effective hand hygiene is essential to prevent the spread of pathogens on produce farms and reduce foodborne illness. The U.S. Food and Drug Administration Food Safety Modernization Act Proposed Rule for Produce Safety recommends the use of soap and running water for hand hygiene of produce handlers. The use of alcohol-based hand sanitizer (ABHS) may be an effective alternative hygiene intervention where access to water is limited. There are no published data on the efficacy of either soap or ABHS-based interventions to reduce microbial contamination in agricultural settings. The goal of this study was to assess the ability of two soap-based (traditional or pumice) and two ABHS-based (label-use or two-step) hygiene interventions to reduce microbes (coliforms, Escherichia coli, and Enterococcus spp.) and soil (absorbance of hand rinsate at 600 nm [A600]) on farmworker hands after harvesting produce, compared with the results for a no-hand-hygiene control. With no hand hygiene, farmworker hands were soiled (median A600, 0.48) and had high concentrations of coliforms (geometric mean, 3.4 log CFU per hand) and Enterococcus spp. (geometric mean, 5.3 log CFU per hand) after 1 to 2 h of harvesting tomatoes. Differences in microbial loads in comparison to the loads in the control group varied by indicator organism and hygiene intervention (0 to 2.3 log CFU per hand). All interventions yielded lower concentrations of Enterococcus spp. and E. coli (P hands (P hand washing with soap at reducing indicator organisms on farmworker hands. Based on these results, ABHS is an efficacious hand hygiene solution for produce handlers, even on soiled hands.

  7. Comparing the Precision of Information Retrieval of MeSH-Controlled Vocabulary Search Method and a Visual Method in the Medline Medical Database.

    Science.gov (United States)

    Hariri, Nadjla; Ravandi, Somayyeh Nadi

    2014-01-01

    Medline is one of the most important databases in the biomedical field. One of the most important hosts for Medline is Elton B. Stephens CO. (EBSCO), which has presented different search methods that can be used based on the needs of the users. Visual search and MeSH-controlled search methods are among the most common methods. The goal of this research was to compare the precision of the retrieved sources in the EBSCO Medline base using MeSH-controlled and visual search methods. This research was a semi-empirical study. By holding training workshops, 70 students of higher education in different educational departments of Kashan University of Medical Sciences were taught MeSH-Controlled and visual search methods in 2012. Then, the precision of 300 searches made by these students was calculated based on Best Precision, Useful Precision, and Objective Precision formulas and analyzed in SPSS software using the independent sample T Test, and three precisions obtained with the three precision formulas were studied for the two search methods. The mean precision of the visual method was greater than that of the MeSH-Controlled search for all three types of precision, i.e. Best Precision, Useful Precision, and Objective Precision, and their mean precisions were significantly different (P searches. Fifty-three percent of the participants in the research also mentioned that the use of the combination of the two methods produced better results. For users, it is more appropriate to use a natural, language-based method, such as the visual method, in the EBSCO Medline host than to use the controlled method, which requires users to use special keywords. The potential reason for their preference was that the visual method allowed them more freedom of action.

  8. Learning in robotic manipulation: The role of dimensionality reduction in policy search methods. Comment on "Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands" by Marco Santello et al.

    Science.gov (United States)

    Ficuciello, Fanny; Siciliano, Bruno

    2016-07-01

    A question that often arises, among researchers working on artificial hands and robotic manipulation, concerns the real meaning of synergies. Namely, are they a realistic representation of the central nervous system control of manipulation activities at different levels and of the sensory-motor manipulation apparatus of the human being, or do they constitute just a theoretical framework exploiting analytical methods to simplify the representation of grasping and manipulation activities? Apparently, this is not a simple question to answer and, in this regard, many minds from the field of neuroscience and robotics are addressing the issue [1]. The interest of robotics is definitely oriented towards the adoption of synergies to tackle the control problem of devices with high number of degrees of freedom (DoFs) which are required to achieve motor and learning skills comparable to those of humans. The synergy concept is useful for innovative underactuated design of anthropomorphic hands [2], while the resulting dimensionality reduction simplifies the control of biomedical devices such as myoelectric hand prostheses [3]. Synergies might also be useful in conjunction with the learning process [4]. This aspect is less explored since few works on synergy-based learning have been realized in robotics. In learning new tasks through trial-and-error, physical interaction is important. On the other hand, advanced mechanical designs such as tendon-driven actuation, underactuated compliant mechanisms and hyper-redundant/continuum robots might exhibit enhanced capabilities of adapting to changing environments and learning from exploration. In particular, high DoFs and compliance increase the complexity of modelling and control of these devices. An analytical approach to manipulation planning requires a precise model of the object, an accurate description of the task, and an evaluation of the object affordance, which all make the process rather time consuming. The integration of

  9. Model-free adaptive control optimization using a chaotic particle swarm approach

    Energy Technology Data Exchange (ETDEWEB)

    Santos Coelho, Leandro dos [Industrial and Systems Engineering Graduate Program, LAS/PPGEPS, Pontifical Catholic University of Parana, PUCPR, Imaculada Conceicao, 1155, 80215-901 Curitiba, Parana (Brazil)], E-mail: leandro.coelho@pucpr.br; Rodrigues Coelho, Antonio Augusto [Department of Automation and Systems, Federal University of Santa Catarina, Box 476, 88040-900 Florianopolis, Santa Catarina (Brazil)], E-mail: aarc@das.ufsc.br

    2009-08-30

    It is well known that conventional control theories are widely suited for applications where the processes can be reasonably described in advance. However, when the plant's dynamics are hard to characterize precisely or are subject to environmental uncertainties, one may encounter difficulties in applying the conventional controller design methodologies. Despite the difficulty in achieving high control performance, the fine tuning of controller parameters is a tedious task that always requires experts with knowledge in both control theory and process information. Nowadays, more and more studies have focused on the development of adaptive control algorithms that can be directly applied to complex processes whose dynamics are poorly modeled and/or have severe nonlinearities. In this context, the design of a Model-Free Learning Adaptive Control (MFLAC) based on pseudo-gradient concepts and optimization procedure by a Particle Swarm Optimization (PSO) approach using constriction coefficient and Henon chaotic sequences (CPSOH) is presented in this paper. PSO is a stochastic global optimization technique inspired by social behavior of bird flocking. The PSO models the exploration of a problem space by a population of particles. Each particle in PSO has a randomized velocity associated to it, which moves through the space of the problem. Since chaotic mapping enjoys certainty, ergodicity and the stochastic property, the proposed CPSOH introduces chaos mapping which introduces some flexibility in particle movements in each iteration. The chaotic sequences allow also explorations at early stages and exploitations at later stages during the search procedure of CPSOH. Motivation for application of CPSOH approach is to overcome the limitation of the conventional MFLAC design, which cannot guarantee satisfactory control performance when the plant has different gains for the operational range when designed by trial-and-error by user. Numerical results of the MFLAC with

  10. Model-free adaptive control optimization using a chaotic particle swarm approach

    International Nuclear Information System (INIS)

    Santos Coelho, Leandro dos; Rodrigues Coelho, Antonio Augusto

    2009-01-01

    It is well known that conventional control theories are widely suited for applications where the processes can be reasonably described in advance. However, when the plant's dynamics are hard to characterize precisely or are subject to environmental uncertainties, one may encounter difficulties in applying the conventional controller design methodologies. Despite the difficulty in achieving high control performance, the fine tuning of controller parameters is a tedious task that always requires experts with knowledge in both control theory and process information. Nowadays, more and more studies have focused on the development of adaptive control algorithms that can be directly applied to complex processes whose dynamics are poorly modeled and/or have severe nonlinearities. In this context, the design of a Model-Free Learning Adaptive Control (MFLAC) based on pseudo-gradient concepts and optimization procedure by a Particle Swarm Optimization (PSO) approach using constriction coefficient and Henon chaotic sequences (CPSOH) is presented in this paper. PSO is a stochastic global optimization technique inspired by social behavior of bird flocking. The PSO models the exploration of a problem space by a population of particles. Each particle in PSO has a randomized velocity associated to it, which moves through the space of the problem. Since chaotic mapping enjoys certainty, ergodicity and the stochastic property, the proposed CPSOH introduces chaos mapping which introduces some flexibility in particle movements in each iteration. The chaotic sequences allow also explorations at early stages and exploitations at later stages during the search procedure of CPSOH. Motivation for application of CPSOH approach is to overcome the limitation of the conventional MFLAC design, which cannot guarantee satisfactory control performance when the plant has different gains for the operational range when designed by trial-and-error by user. Numerical results of the MFLAC with CPSOH

  11. Hand eczema classification

    DEFF Research Database (Denmark)

    Diepgen, T L; Andersen, Klaus Ejner; Brandao, F M

    2008-01-01

    of the disease is rarely evidence based, and a classification system for different subdiagnoses of hand eczema is not agreed upon. Randomized controlled trials investigating the treatment of hand eczema are called for. For this, as well as for clinical purposes, a generally accepted classification system...... A classification system for hand eczema is proposed. Conclusions It is suggested that this classification be used in clinical work and in clinical trials....

  12. Multi-fingered robotic hand

    Science.gov (United States)

    Ruoff, Carl F. (Inventor); Salisbury, Kenneth, Jr. (Inventor)

    1990-01-01

    A robotic hand is presented having a plurality of fingers, each having a plurality of joints pivotally connected one to the other. Actuators are connected at one end to an actuating and control mechanism mounted remotely from the hand and at the other end to the joints of the fingers for manipulating the fingers and passing externally of the robot manipulating arm in between the hand and the actuating and control mechanism. The fingers include pulleys to route the actuators within the fingers. Cable tension sensing structure mounted on a portion of the hand are disclosed, as is covering of the tip of each finger with a resilient and pliable friction enhancing surface.

  13. Recognizing the Operating Hand and the Hand-Changing Process for User Interface Adjustment on Smartphones

    Directory of Open Access Journals (Sweden)

    Hansong Guo

    2016-08-01

    Full Text Available As the size of smartphone touchscreens has become larger and larger in recent years, operability with a single hand is getting worse, especially for female users. We envision that user experience can be significantly improved if smartphones are able to recognize the current operating hand, detect the hand-changing process and then adjust the user interfaces subsequently. In this paper, we proposed, implemented and evaluated two novel systems. The first one leverages the user-generated touchscreen traces to recognize the current operating hand, and the second one utilizes the accelerometer and gyroscope data of all kinds of activities in the user’s daily life to detect the hand-changing process. These two systems are based on two supervised classifiers constructed from a series of refined touchscreen trace, accelerometer and gyroscope features. As opposed to existing solutions that all require users to select the current operating hand or confirm the hand-changing process manually, our systems follow much more convenient and practical methods and allow users to change the operating hand frequently without any harm to the user experience. We conduct extensive experiments on Samsung Galaxy S4 smartphones, and the evaluation results demonstrate that our proposed systems can recognize the current operating hand and detect the hand-changing process with 94.1% and 93.9% precision and 94.1% and 93.7% True Positive Rates (TPR respectively, when deciding with a single touchscreen trace or accelerometer-gyroscope data segment, and the False Positive Rates (FPR are as low as 2.6% and 0.7% accordingly. These two systems can either work completely independently and achieve pretty high accuracies or work jointly to further improve the recognition accuracy.

  14. Recognizing the Operating Hand and the Hand-Changing Process for User Interface Adjustment on Smartphones †

    Science.gov (United States)

    Guo, Hansong; Huang, He; Huang, Liusheng; Sun, Yu-E

    2016-01-01

    As the size of smartphone touchscreens has become larger and larger in recent years, operability with a single hand is getting worse, especially for female users. We envision that user experience can be significantly improved if smartphones are able to recognize the current operating hand, detect the hand-changing process and then adjust the user interfaces subsequently. In this paper, we proposed, implemented and evaluated two novel systems. The first one leverages the user-generated touchscreen traces to recognize the current operating hand, and the second one utilizes the accelerometer and gyroscope data of all kinds of activities in the user’s daily life to detect the hand-changing process. These two systems are based on two supervised classifiers constructed from a series of refined touchscreen trace, accelerometer and gyroscope features. As opposed to existing solutions that all require users to select the current operating hand or confirm the hand-changing process manually, our systems follow much more convenient and practical methods and allow users to change the operating hand frequently without any harm to the user experience. We conduct extensive experiments on Samsung Galaxy S4 smartphones, and the evaluation results demonstrate that our proposed systems can recognize the current operating hand and detect the hand-changing process with 94.1% and 93.9% precision and 94.1% and 93.7% True Positive Rates (TPR) respectively, when deciding with a single touchscreen trace or accelerometer-gyroscope data segment, and the False Positive Rates (FPR) are as low as 2.6% and 0.7% accordingly. These two systems can either work completely independently and achieve pretty high accuracies or work jointly to further improve the recognition accuracy. PMID:27556461

  15. New frontiers in the rubber hand experiment: when a robotic hand becomes one's own.

    Science.gov (United States)

    Caspar, Emilie A; De Beir, Albert; Magalhaes De Saldanha Da Gama, Pedro A; Yernaux, Florence; Cleeremans, Axel; Vanderborght, Bram

    2015-09-01

    The rubber hand illusion is an experimental paradigm in which participants consider a fake hand to be part of their body. This paradigm has been used in many domains of psychology (i.e., research on pain, body ownership, agency) and is of clinical importance. The classic rubber hand paradigm nevertheless suffers from limitations, such as the absence of active motion or the reliance on approximate measurements, which makes strict experimental conditions difficult to obtain. Here, we report on the development of a novel technology-a robotic, user- and computer-controllable hand-that addresses many of the limitations associated with the classic rubber hand paradigm. Because participants can actively control the robotic hand, the device affords higher realism and authenticity. Our robotic hand has a comparatively low cost and opens up novel and innovative methods. In order to validate the robotic hand, we have carried out three experiments. The first two studies were based on previous research using the rubber hand, while the third was specific to the robotic hand. We measured both sense of agency and ownership. Overall, results show that participants experienced a "robotic hand illusion" in the baseline conditions. Furthermore, we also replicated previous results about agency and ownership.

  16. The control of a free-piston engine generator. Part 1: Fundamental analyses

    Energy Technology Data Exchange (ETDEWEB)

    Mikalsen, R.; Roskilly, A.P. [Sir Joseph Swan Institute for Energy Research, Newcastle University, Newcastle upon Tyne, NE1 7RU, England (United Kingdom)

    2010-04-15

    Free-piston engines are under investigation by a number of research groups due to potential fuel efficiency and exhaust emissions advantages over conventional technology. The main challenge with such engines is the control of the piston motion, and this has not yet been fully resolved for all types of free-piston engines. This paper discusses the basic features of a single piston free-piston engine generator under development at Newcastle University and investigates engine control issues using a full-cycle simulation model. Control variables and disturbances are identified, and a control strategy is proposed. It is found that the control of the free-piston engine is a challenge, but that the proposed control strategy is feasible. Engine speed control does, however, represent a challenge in the current design. (author)

  17. Research on Precision Tracking on Fast Steering Mirror and Control Strategy

    Science.gov (United States)

    Di, Lin; Yi-ming, Wu; Fan, Zhu

    2018-01-01

    Fast steering mirror is a device used for controlling the beam direction precisely. Due to the short travel of the push-pull FSM, a compound fast steering mirror system driven by both limited-angle voice coil motor and push-pull FSM together is proposed. In the compound FSM system, limited-angle voice coil motor quickly swings at wide angle, while the push-pull FSM do high frequency movement in a small range, which provides the system with the high bandwidth and long travel. In the control strategy, the method of combining feed-forward control in Kalman filtering with auto-disturbance rejection control is used to improve trajectory tracking accuracy. The simulation result shows that tracking accuracy measured by the compound method can be improved by more than 5 times than that of the conventional PID.

  18. The hot hand belief and framing effects.

    Science.gov (United States)

    MacMahon, Clare; Köppen, Jörn; Raab, Markus

    2014-09-01

    Recent evidence of the hot hand in sport-where success breeds success in a positive recency of successful shots, for instance-indicates that this pattern does not actually exist. Yet the belief persists. We used 2 studies to explore the effects of framing on the hot hand belief in sport. We looked at the effect of sport experience and task on the perception of baseball pitch behavior as well as the hot hand belief and free-throw behavior in basketball. Study 1 asked participants to designate outcomes with different alternation rates as the result of baseball pitches or coin tosses. Study 2 examined basketball free-throw behavior and measured predicted success before each shot as well as general belief in the hot hand pattern. The results of Study 1 illustrate that experience and stimulus alternation rates influence the perception of chance in human performance tasks. Study 2 shows that physically performing an act and making judgments are related. Specifically, beliefs were related to overall performance, with more successful shooters showing greater belief in the hot hand and greater predicted success for upcoming shots. Both of these studies highlight that the hot hand belief is influenced by framing, which leads to instability and situational contingencies. We show the specific effects of framing using accumulated experience of the individual with the sport and knowledge of its structure and specific experience with sport actions (basketball shots) prior to judgments.

  19. Symmetric grey box identification and distributed beam-based controller design for free-electron lasers

    Energy Technology Data Exchange (ETDEWEB)

    Pfeiffer, Sven

    2014-09-15

    The European X-ray Free-Electron Laser (XFEL) at the Deutsches Elektronen Synchtrotron (DESY) in Hamburg will, starting in 2015, open up completely new research opportunities for scientist and industrial users by exploiting ultrashort X-ray laser pulses. Bunches of electrons are accelerated by a radio frequency field inside superconducting cavities up to an energy of 17.5 GeV. A periodic arrangement of magnets forces the accelerated electrons onto a tight slalom path leading to a process in that the electrons emit extremely short and intense X-ray flashes. The generation of equidistant X-ray flashes with a constant intensity requires an extremely high precision field control in combination with beam-based signals. FLASH, which can be seen as a pilot test facility, allows to develop and test controller concepts even before the European XFEL is in operation. In this thesis it is shown that a physical white box model structure, which describes the behavior of each subsystem within the radio frequency field control loop, obeys as first-order approximation the special orthogonal group of dimension two (SO(2)). Presented is a grey box identification approach, which combines the physical model structure with general identification methods. The accelerator modules are operated in a pulsed mode. Thus, the excitation of the system and therefore the identification of the input-output behavior is only possible within a short time period. Developed is an adaptive identification approach with a specified SO(2) symmetric model structure. The proposed controller design strategy fulfills the requirements of a high precision field performance. Adapting the feedforward signal by using an iterative learning control (ILC) algorithm reduces remaining repetitive field errors from pulse to pulse. It is shown, that exploiting the SO(2) symmetric structure and using the developed tensor based ILC representation simplifies the feedforward update computation. Magnetic chicanes, so

  20. Symmetric grey box identification and distributed beam-based controller design for free-electron lasers

    International Nuclear Information System (INIS)

    Pfeiffer, Sven

    2014-09-01

    The European X-ray Free-Electron Laser (XFEL) at the Deutsches Elektronen Synchtrotron (DESY) in Hamburg will, starting in 2015, open up completely new research opportunities for scientist and industrial users by exploiting ultrashort X-ray laser pulses. Bunches of electrons are accelerated by a radio frequency field inside superconducting cavities up to an energy of 17.5 GeV. A periodic arrangement of magnets forces the accelerated electrons onto a tight slalom path leading to a process in that the electrons emit extremely short and intense X-ray flashes. The generation of equidistant X-ray flashes with a constant intensity requires an extremely high precision field control in combination with beam-based signals. FLASH, which can be seen as a pilot test facility, allows to develop and test controller concepts even before the European XFEL is in operation. In this thesis it is shown that a physical white box model structure, which describes the behavior of each subsystem within the radio frequency field control loop, obeys as first-order approximation the special orthogonal group of dimension two (SO(2)). Presented is a grey box identification approach, which combines the physical model structure with general identification methods. The accelerator modules are operated in a pulsed mode. Thus, the excitation of the system and therefore the identification of the input-output behavior is only possible within a short time period. Developed is an adaptive identification approach with a specified SO(2) symmetric model structure. The proposed controller design strategy fulfills the requirements of a high precision field performance. Adapting the feedforward signal by using an iterative learning control (ILC) algorithm reduces remaining repetitive field errors from pulse to pulse. It is shown, that exploiting the SO(2) symmetric structure and using the developed tensor based ILC representation simplifies the feedforward update computation. Magnetic chicanes, so

  1. Fully embedded myoelectric control for a wearable robotic hand orthosis.

    Science.gov (United States)

    Ryser, Franziska; Butzer, Tobias; Held, Jeremia P; Lambercy, Olivier; Gassert, Roger

    2017-07-01

    To prevent learned non-use of the affected hand in chronic stroke survivors, rehabilitative training should be continued after discharge from the hospital. Robotic hand orthoses are a promising approach for home rehabilitation. When combined with intuitive control based on electromyography, the therapy outcome can be improved. However, such systems often require extensive cabling, experience in electrode placement and connection to external computers. This paper presents the framework for a stand-alone, fully wearable and real-time myoelectric intention detection system based on the Myo armband. The hard and software for real-time gesture classification were developed and combined with a routine to train and customize the classifier, leading to a unique ease of use. The system including training of the classifier can be set up within less than one minute. Results demonstrated that: (1) the proposed algorithm can classify five gestures with an accuracy of 98%, (2) the final system can online classify three gestures with an accuracy of 94.3% and, in a preliminary test, (3) classify three gestures from data acquired from mildly to severely impaired stroke survivors with an accuracy of over 78.8%. These results highlight the potential of the presented system for electromyography-based intention detection for stroke survivors and, with the integration of the system into a robotic hand orthosis, the potential for a wearable platform for all day robot-assisted home rehabilitation.

  2. Method of Grasping Control by Computing Internal and External Impedances for Two Robot Fingers, and Its Application to Admittance Control of a Robot Hand-Arm System

    Directory of Open Access Journals (Sweden)

    Jian Huang

    2015-08-01

    Full Text Available Impedance control is an important technology used in the grasping control of a robot hand. Numerous studies related to grasping algorithms have been reported in recent years, with the contact force between robot fingers and the object to be grasped being primarily discussed in most cases. Generally, a coupling effect occurs between the internal loop of the grasping operation and the external loop of the interaction with the environment when a multi-fingered robot hand is used to complete a contact task. Therefore, a robot hand cannot hold an object using a large external force to complete a wide range of tasks by applying the conventional method. In this paper, the coupling of the internal/external forces occurring in grasping operations using multiple fingers is analysed. Then, improved impedance control based on the previous method is proposed as an effective tool to solve the problem of grasping failure caused by single-finger contact. Furthermore, a method for applying the improved grasping algorithm to the admittance control of a robot hand-arm system is also proposed. The proposed method divides the impedance effect into the grasping control of the hand and the cooperative control of the arm, so that expanding the task space and increasing the flexibility of impedance adjustment can be achieved. Experiments were conducted to demonstrate the effectiveness of the proposed method.

  3. Donor-site morbidity of the radial forearm free flap versus the ulnar forearm free flap.

    Science.gov (United States)

    Hekner, Dominique D; Abbink, Jan H; van Es, Robert J; Rosenberg, Antoine; Koole, Ronald; Van Cann, Ellen M

    2013-08-01

    Donor-site morbidity following harvest of the radial forearm free flap was compared with that following harvest of the ulnar forearm free flap. Twenty-eight radial forearm and 27 ulnar forearm flaps were harvested in 55 patients with head and neck defects. Pressure perception was measured with Semmes-Weinstein monofilaments. Cold perception was tested with chloroethyl. Donor-site healing was evaluated. Patients were interviewed about grip and pinch strength and donor-site appearance. In the radial forearm free flap group, pressure perception and cold perception were reduced in the donor hand, whereas in the ulnar group, no differences were observed between the donor and unoperated hands. In the radial forearm group, 15 percent of patients experienced reduced strength in the donor hand, whereas in the ulnar forearm group, none of the patients reported reduced strength in the donor hand. In the radial forearm group, 14 percent had partial or complete loss of the skin graft, whereas in the ulnar forearm group, 4 percent had partial loss of the skin graft. In the radial forearm group, 18 percent of patients were dissatisfied with the appearance of the donor site, and no complaints were reported in the ulnar forearm group. The authors' study shows less donor site-morbidity following harvest of the ulnar forearm free flap than following harvest of the radial forearm free flap. These results emphasize that the ulnar forearm free flap should be considered as an alternative for the radial forearm free flap for reconstruction of soft-tissue defects. Therapeutic, III.

  4. Humans can integrate force feedback to toes in their sensorimotor control of a robotic hand.

    Science.gov (United States)

    Panarese, Alessandro; Edin, Benoni B; Vecchi, Fabrizio; Carrozza, Maria C; Johansson, Roland S

    2009-12-01

    Tactile sensory feedback is essential for dexterous object manipulation. Users of hand myoelectric prostheses without tactile feedback must depend essentially on vision to control their device. Indeed, improved tactile feedback is one of their main priorities. Previous research has provided evidence that conveying tactile feedback can improve prostheses control, although additional effort is required to solve problems related to pattern recognition learning, unpleasant sensations, sensory adaptation, and low spatiotemporal resolution. Still, these studies have mainly focused on providing stimulation to hairy skin regions close to the amputation site, i.e., usually to the upper arm. Here, we explored the possibility to provide tactile feedback to the glabrous skin of toes, which have mechanical and neurophysiological properties similar to the fingertips. We explored this paradigm in a grasp-and-lift task, in which healthy participants controlled two opposing digits of a robotic hand by changing the spacing of their index finger and thumb. The normal forces applied by the robotic fingertips to a test object were fed back to the right big and second toe. We show that within a few lifting trials, all the participants incorporated the force feedback received by the foot in their sensorimotor control of the robotic hand.

  5. Smoke-Free Workplaces Are Associated with Protection from Second-Hand Smoke at Homes in Nigeria: Evidence for Population-Level Decisions

    Directory of Open Access Journals (Sweden)

    Dorota Kaleta

    2015-01-01

    Full Text Available The evidence suggests that smoke-free workplace policies may change social norms towards exposing others to second-hand smoke at home. The aim of the study was to assess whether being employed in a smoke-free workplace (SFWP is associated with living in a smoke-free home (SFH. We used the data from the Global Adult Tobacco Survey conducted in Nigeria in 2012, in which 9,765 individuals were interviewed including 1,856 persons who worked indoors. The percentage of Nigerians employed in SFWP that reported living in a SFH was higher compared to those employed in a workplace where smoking occurred (95% versus 73%. Working in a SFWP was associated with a significantly higher likelihood of living in a SFH (OR = 5.3; p<0.001. Urban inhabitants indicated more frequently that they lived in SFH compared to rural residents (OR = 2.0; p=0.006. The odds of living in a SFH were significantly higher among nonsmokers and nonsmokeless tobacco users compared to smokers and smokeless tobacco users (OR = 28.8; p<0.001; OR = 7.0; p<0.001. These findings support the need for implementation of comprehensive smoke-free policies in Nigeria that result in substantial health benefits.

  6. Mind the hand

    DEFF Research Database (Denmark)

    Davidsen, Jacob; Christiansen, Ellen Tove

    2014-01-01

    Apart from touching the screen, what is the role of the hands for children collaborating around touchscreens? Based on embodied and multimodal interaction analysis of 8- and 9-year old pairs collaborating around touchscreens, we conclude that children use their hands to constrain and control acce...

  7. LISA Pathfinder drag-free control and system implications

    International Nuclear Information System (INIS)

    Fichter, Walter; Gath, Peter; Vitale, Stefano; Bortoluzzi, Daniele

    2005-01-01

    The top-level requirement of the LISA Pathfinder mission is the verification of pure relative free fall between two test masses with an accuracy of about 3 x 10 -14 m s -2 Hz -1/2 in a measurement bandwidth between 1 mHz and 30 mHz. The drag-free control system is one of the key technology elements that shall be verified. Its design is strongly connected to the overall system and experimental design, in particular, via the following issues: the differential test mass motion and thus the science measurements depend on the control system; design constraints, such as negative stiffness of test masses and electrostatic actuation cross-talk, have an impact on science and control system performance; derived requirements for control system components, in particular, the micro-propulsion system, must be within reasonable and feasible limits. In this paper, the control design approach is outlined and the system-related issues are addressed

  8. Learning to play the violin: motor control by freezing, not freeing degrees of freedom.

    Science.gov (United States)

    Konczak, Jürgen; Vander Velden, Heidi; Jaeger, Lukas

    2009-05-01

    Playing a violin requires precise patterns of limb coordination that are acquired over years of practice. In the present study, the authors investigated how motion at proximal arm joints influenced the precision of bow movements in novice learners and experts. The authors evaluated the performances of 11 children (4-12 years old), 3 beginning-to-advanced level adult players, and 2 adult concert violinists, using a musical work that all had mastered as their first violin piece. The authors found that learning to play the violin was not associated with a release or freeing of joint degrees of freedom. Instead, learning was characterized by an experience-dependent suppression of sagittal shoulder motion, as documented by an observed reduction in joint angular amplitude. This reduction in the amplitude of shoulder flexion-extension correlated highly with a decrease of bow-movement variability. The remaining mechanical degrees of freedom at the elbow and shoulder showed patterns of neither suppression nor freeing. Only violinists with more than 700 practice hr achieved sagittal shoulder range of motion comparable to experts. The findings imply that restricting joint amplitude at selected joint degrees of freedom, while leaving other degrees of freedom unconstrained, constitutes an appropriate strategy for learning complex, high-precision motor patterns in children and adults. The findings also highlight that mastering even seemingly simple bowing movements constitutes a prolonged learning process.

  9. Design and validation of a portable, inexpensive and multi-beam timing light system using the Nintendo Wii hand controllers.

    Science.gov (United States)

    Clark, Ross A; Paterson, Kade; Ritchie, Callan; Blundell, Simon; Bryant, Adam L

    2011-03-01

    Commercial timing light systems (CTLS) provide precise measurement of athletes running velocity, however they are often expensive and difficult to transport. In this study an inexpensive, wireless and portable timing light system was created using the infrared camera in Nintendo Wii hand controllers (NWHC). System creation with gold-standard validation. A Windows-based software program using NWHC to replicate a dual-beam timing gate was created. Firstly, data collected during 2m walking and running trials were validated against a 3D kinematic system. Secondly, data recorded during 5m running trials at various intensities from standing or flying starts were compared to a single beam CTLS and the independent and average scores of three handheld stopwatch (HS) operators. Intraclass correlation coefficient and Bland-Altman plots were used to assess validity. Absolute error quartiles and percentage of trials in absolute error threshold ranges were used to determine accuracy. The NWHC system was valid when compared against the 3D kinematic system (ICC=0.99, median absolute error (MAR)=2.95%). For the flying 5m trials the NWHC system possessed excellent validity and precision (ICC=0.97, MAR8%). A NWHC timing light system is inexpensive, portable and valid for assessing running velocity. Errors in the 5m standing start trials may have been due to erroneous event detection by either the commercial or NWHC-based timing light systems. Copyright © 2010 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  10. Assessment of Myoelectric Controller Performance and Kinematic Behavior of a Novel Soft Synergy-Inspired Robotic Hand for Prosthetic Applications.

    Science.gov (United States)

    Fani, Simone; Bianchi, Matteo; Jain, Sonal; Pimenta Neto, José Simões; Boege, Scott; Grioli, Giorgio; Bicchi, Antonio; Santello, Marco

    2016-01-01

    Myoelectric artificial limbs can significantly advance the state of the art in prosthetics, since they can be used to control mechatronic devices through muscular activity in a way that mimics how the subjects used to activate their muscles before limb loss. However, surveys indicate that dissatisfaction with the functionality of terminal devices underlies the widespread abandonment of prostheses. We believe that one key factor to improve acceptability of prosthetic devices is to attain human likeness of prosthesis movements, a goal which is being pursued by research on social and human-robot interactions. Therefore, to reduce early abandonment of terminal devices, we propose that controllers should be designed so as to ensure effective task accomplishment in a natural fashion. In this work, we have analyzed and compared the performance of three types of myoelectric controller algorithms based on surface electromyography to control an underactuated and multi-degrees of freedom prosthetic hand, the SoftHand Pro. The goal of the present study was to identify the myoelectric algorithm that best mimics the native hand movements. As a preliminary step, we first quantified the repeatability of the SoftHand Pro finger movements and identified the electromyographic recording sites for able-bodied individuals with the highest signal-to-noise ratio from two pairs of muscles, i.e., flexor digitorum superficialis/extensor digitorum communis, and flexor carpi radialis/extensor carpi ulnaris. Able-bodied volunteers were then asked to execute reach-to-grasp movements, while electromyography signals were recorded from flexor digitorum superficialis/extensor digitorum communis as this was identified as the muscle pair characterized by high signal-to-noise ratio and intuitive control. Subsequently, we tested three myoelectric controllers that mapped electromyography signals to position of the SoftHand Pro. We found that a differential electromyography-to-position mapping ensured the

  11. Assessment of Myoelectric Controller Performance and Kinematic Behavior of a Novel Soft Synergy-inspired Robotic Hand for Prosthetic Applications

    Directory of Open Access Journals (Sweden)

    Simone Fani

    2016-10-01

    Full Text Available Myoelectric-artificial limbs can significantly advance the state of the art in prosthetics, since they can be used to control mechatronic devices through muscular activity in a way that mimics how the subjects used to activate their muscles before limb loss. However, surveys indicate that dissatisfaction with the functionality of terminal devices underlies the widespread abandonment of prostheses. We believe that one key factor to improve acceptability of prosthetic devices is to attain human-likeness of prosthesis movements, a goal which is being pursued by research on social and human-robot interactions. Therefore, to reduce early abandonment of terminal devices, we propose that controllers should be designed such as to ensure effective task accomplishment in a natural fashion. In this work, we have analyzed and compared the performance of three types of myoelectric controller algorithms based on surface electromyography to control an under-actuated and multi-degrees of freedom prosthetic hand, the SoftHand Pro. The goal of the present study was to identify the myoelectric algorithm that best mimics the native hand movements. As a preliminary step, we first quantified the repeatability of the SoftHand Pro finger movements and identified the electromyographic recording sites for able-bodied individuals with the highest signal-to-noise ratio from two pairs of muscles, i.e. flexor digitorum superficialis/extensor digitorum communis, and flexor carpi radialis/extensor carpi ulnaris. Able-bodied volunteers were then asked to execute reach-to-grasp movements, while electromyography signals were recorded from flexor digitorum superficialis/extensor digitorum communis as this was identified as the muscle pair characterized by high signal-to-noise ratio and intuitive control. Subsequently, we tested three myoelectric controllers that mapped electromyography signals to position of the SoftHand Pro. We found that a differential electromyography

  12. Kinect technology for hand tracking control of surgical robots: technical and surgical skill comparison to current robotic masters.

    Science.gov (United States)

    Kim, Yonjae; Leonard, Simon; Shademan, Azad; Krieger, Axel; Kim, Peter C W

    2014-06-01

    Current surgical robots are controlled by a mechanical master located away from the patient, tracking surgeon's hands by wire and pulleys or mechanical linkage. Contactless hand tracking for surgical robot control is an attractive alternative, because it can be executed with minimal footprint at the patient's bedside without impairing sterility, while eliminating current disassociation between surgeon and patient. We compared technical and technologic feasibility of contactless hand tracking to the current clinical standard master controllers. A hand-tracking system (Kinect™-based 3Gear), a wire-based mechanical master (Mantis Duo), and a clinical mechanical linkage master (da Vinci) were evaluated for technical parameters with strong clinical relevance: system latency, static noise, robot slave tremor, and controller range. Five experienced surgeons performed a skill comparison study, evaluating the three different master controllers for efficiency and accuracy in peg transfer and pointing tasks. da Vinci had the lowest latency of 89 ms, followed by Mantis with 374 ms and 3Gear with 576 ms. Mantis and da Vinci produced zero static error. 3Gear produced average static error of 0.49 mm. The tremor of the robot used by the 3Gear and Mantis system had a radius of 1.7 mm compared with 0.5 mm for da Vinci. The three master controllers all had similar range. The surgeons took 1.98 times longer to complete the peg transfer task with the 3Gear system compared with Mantis, and 2.72 times longer with Mantis compared with da Vinci (p value 2.1e-9). For the pointer task, surgeons were most accurate with da Vinci with average error of 0.72 mm compared with Mantis's 1.61 mm and 3Gear's 2.41 mm (p value 0.00078). Contactless hand-tracking technology as a surgical master can execute simple surgical tasks. Whereas traditional master controllers outperformed, given that contactless hand-tracking is a first-generation technology, clinical potential is promising and could

  13. Access to waterless hand sanitizer improves student hand hygiene behavior in primary schools in Nairobi, Kenya.

    Science.gov (United States)

    Pickering, Amy J; Davis, Jennifer; Blum, Annalise G; Scalmanini, Jenna; Oyier, Beryl; Okoth, George; Breiman, Robert F; Ram, Pavani K

    2013-09-01

    Handwashing is difficult in settings with limited resources and water access. In primary schools within urban Kibera, Kenya, we investigated the impact of providing waterless hand sanitizer on student hand hygiene behavior. Two schools received a waterless hand sanitizer intervention, two schools received a handwashing with soap intervention, and two schools received no intervention. Hand cleaning behavior after toilet use was monitored for 2 months using structured observation. Hand cleaning after toileting was 82% at sanitizer schools (N = 2,507 toileting events), 38% at soap schools (N = 3,429), and 37% at control schools (N = 2,797). Students at sanitizer schools were 23% less likely to have observed rhinorrhea than control students (P = 0.02); reductions in student-reported gastrointestinal and respiratory illness symptoms were not statistically significant. Providing waterless hand sanitizer markedly increased student hand cleaning after toilet use, whereas the soap intervention did not. Waterless hand sanitizer may be a promising option to improve student hand cleansing behavior, particularly in schools with limited water access.

  14. Hand held control unit for controlling a display screen-oriented computer game, and a display screen-oriented computer game having one or more such control units

    NARCIS (Netherlands)

    2001-01-01

    A hand-held control unit is used to control a display screen-oriented computer game. The unit comprises a housing with a front side, a set of control members lying generally flush with the front side for through actuating thereof controlling actions of in-game display items, and an output for

  15. Precision of INR measured with a patient operated whole blood coagulometer

    DEFF Research Database (Denmark)

    Attermann, Jørn; Andersen, Niels Trolle; Korsgaard, Helle

    2003-01-01

    INTRODUCTION: The objective of the present study was to evaluate the precision of a portable whole blood coagulometer (CoaguChek S) in the hands of self-managing patients on oral anticoagulant therapy (OAT). MATERIALS AND METHODS: Fifteen patients on self-managed OAT performed measurements of INR...... and between patients was 15.0% and 14.7%, respectively. CONCLUSION: The precision of CoaguChek S is satisfactory....

  16. The SmartHand transradial prosthesis

    Directory of Open Access Journals (Sweden)

    Carrozza Maria Chiara

    2011-05-01

    Full Text Available Abstract Background Prosthetic components and control interfaces for upper limb amputees have barely changed in the past 40 years. Many transradial prostheses have been developed in the past, nonetheless most of them would be inappropriate if/when a large bandwidth human-machine interface for control and perception would be available, due to either their limited (or inexistent sensorization or limited dexterity. SmartHand tackles this issue as is meant to be clinically experimented in amputees employing different neuro-interfaces, in order to investigate their effectiveness. This paper presents the design and on bench evaluation of the SmartHand. Methods SmartHand design was bio-inspired in terms of its physical appearance, kinematics, sensorization, and its multilevel control system. Underactuated fingers and differential mechanisms were designed and exploited in order to fit all mechatronic components in the size and weight of a natural human hand. Its sensory system was designed with the aim of delivering significant afferent information to the user through adequate interfaces. Results SmartHand is a five fingered self-contained robotic hand, with 16 degrees of freedom, actuated by 4 motors. It integrates a bio-inspired sensory system composed of 40 proprioceptive and exteroceptive sensors and a customized embedded controller both employed for implementing automatic grasp control and for potentially delivering sensory feedback to the amputee. It is able to perform everyday grasps, count and independently point the index. The weight (530 g and speed (closing time: 1.5 seconds are comparable to actual commercial prostheses. It is able to lift a 10 kg suitcase; slippage tests showed that within particular friction and geometric conditions the hand is able to stably grasp up to 3.6 kg cylindrical objects. Conclusions Due to its unique embedded features and human-size, the SmartHand holds the promise to be experimentally fitted on transradial

  17. Compensatory motor control after stroke: an alternative joint strategy for object-dependent shaping of hand posture.

    Science.gov (United States)

    Raghavan, Preeti; Santello, Marco; Gordon, Andrew M; Krakauer, John W

    2010-06-01

    Efficient grasping requires planned and accurate coordination of finger movements to approximate the shape of an object before contact. In healthy subjects, hand shaping is known to occur early in reach under predominantly feedforward control. In patients with hemiparesis after stroke, execution of coordinated digit motion during grasping is impaired as a result of damage to the corticospinal tract. The question addressed here is whether patients with hemiparesis are able to compensate for their execution deficit with a qualitatively different grasp strategy that still allows them to differentiate hand posture to object shape. Subjects grasped a rectangular, concave, and convex object while wearing an instrumented glove. Reach-to-grasp was divided into three phases based on wrist kinematics: reach acceleration (reach onset to peak horizontal wrist velocity), reach deceleration (peak horizontal wrist velocity to reach offset), and grasp (reach offset to lift-off). Patients showed reduced finger abduction, proximal interphalangeal joint (PIP) flexion, and metacarpophalangeal joint (MCP) extension at object grasp across all three shapes compared with controls; however, they were able to partially differentiate hand posture for the convex and concave shapes using a compensatory strategy that involved increased MCP flexion rather than the PIP flexion seen in controls. Interestingly, shape-specific hand postures did not unfold initially during reach acceleration as seen in controls, but instead evolved later during reach deceleration, which suggests increased reliance on sensory feedback. These results indicate that kinematic analysis can identify and quantify within-limb compensatory motor control strategies after stroke. From a clinical perspective, quantitative study of compensation is important to better understand the process of recovery from brain injury. From a motor control perspective, compensation can be considered a model for how joint redundancy is exploited

  18. The Free-Hand Technique for S2-Alar-Iliac Screw Placement: A Safe and Effective Method for Sacropelvic Fixation in Adult Spinal Deformity.

    Science.gov (United States)

    Shillingford, Jamal N; Laratta, Joseph L; Tan, Lee A; Sarpong, Nana O; Lin, James D; Fischer, Charla R; Lehman, Ronald A; Kim, Yongjung J; Lenke, Lawrence G

    2018-02-21

    Spinopelvic fixation is an integral part of achieving solid fusion across the lumbosacral junction, especially in deformity procedures requiring substantial correction or long-segment constructs. Traditional S2-alar-iliac (S2AI) screw-placement techniques utilize fluoroscopy, increasing operative time and radiation exposure to the patient and surgeon. We describe a novel free-hand technique for S2AI screw placement in patients with adult spinal deformity. We reviewed the records of 45 consecutive patients who underwent spinopelvic fixation performed with use of S2AI screws by the senior surgeon and various fellows or residents over a 12-month period (2015 to 2016). In each case, the S2AI screws were placed utilizing a free-hand technique without fluoroscopic or image guidance. Screw position and accuracy were assessed by intraoperative O-arm imaging and analyzed using 3-dimensional interactive manipulation of computed tomography images. A total of 100 screws were placed, 51 by the senior surgeon and 49 by trainees. The mean patient age was 57.4 ± 12.7 years at the time of surgery; 37 (82.2%) of the patients were female. Preoperative diagnoses included adult idiopathic scoliosis (n = 19), adult degenerative scoliosis (n = 15), flatback syndrome (n = 2), fixed sagittal imbalance (n = 6), and distal junctional kyphosis (n = 3). Five (5%) of the screws were placed with moderate to severe cortical breaches, all of which perforated the pelvis posteriorly, with no clinically notable neurovascular or visceral complications. The breach rate did not differ significantly between the senior surgeon and trainees. The free-hand technique for S2AI screw placement, when performed in a standardized manner, was demonstrated to be safe and reliable in constructs requiring spinopelvic fixation. The accuracy of screw placement relies on visible and palpable anatomic landmarks that obviate the need for intraoperative fluoroscopy or image guidance, potentially reducing operative time

  19. Googling your hand hygiene data: Using Google Forms, Google Sheets, and R to collect and automate analysis of hand hygiene compliance monitoring.

    Science.gov (United States)

    Wiemken, Timothy L; Furmanek, Stephen P; Mattingly, William A; Haas, Janet; Ramirez, Julio A; Carrico, Ruth M

    2018-06-01

    Hand hygiene is one of the most important interventions in the quest to eliminate healthcare-associated infections, and rates in healthcare facilities are markedly low. Since hand hygiene observation and feedback are critical to improve adherence, we created an easy-to-use, platform-independent hand hygiene data collection process and an automated, on-demand reporting engine. A 3-step approach was used for this project: 1) creation of a data collection form using Google Forms, 2) transfer of data from the form to a spreadsheet using Google Spreadsheets, and 3) creation of an automated, cloud-based analytics platform for report generation using R and RStudio Shiny software. A video tutorial of all steps in the creation and use of this free tool can be found on our YouTube channel: https://www.youtube.com/watch?v=uFatMR1rXqU&t. The on-demand reporting tool can be accessed at: https://crsp.louisville.edu/shiny/handhygiene. This data collection and automated analytics engine provides an easy-to-use environment for evaluating hand hygiene data; it also provides rapid feedback to healthcare workers. By reducing some of the data management workload required of the infection preventionist, more focused interventions may be instituted to increase global hand hygiene rates and reduce infection. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  20. studies on solvent extraction of free hydrogen cyanide from river water

    African Journals Online (AJOL)

    A method for free and strongly complexed cyanide measurement in river water was developed. Recovery tests from solution with and without river water, using various solvent combinations and background control were investigated to obtain an accurate and precise extraction method for the measurement of hydrogen ...

  1. Clean Hands Count

    Medline Plus

    Full Text Available ... why Close Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed ...

  2. Clinical application of computerized evaluation and re-education biofeedback prototype for sensorimotor control of the hand in stroke patients.

    Science.gov (United States)

    Hsu, Hsiu-Yun; Lin, Cheng-Feng; Su, Fong-Chin; Kuo, Huan-Ting; Chiu, Haw-Yen; Kuo, Li-Chieh

    2012-05-09

    Hemianaesthesia patients usually exhibit awkward and inefficient finger movements of the affected hands. Conventionally, most interventions emphasize the improvement of motor deficits, but rarely address sensory capability and sensorimotor control following stroke. Thus it is critical for stroke patients with sensory problems to incorporate appropriate strategies for dealing with sensory impairment, into traditional hand function rehabilitation programs. In this study, we used a custom-designed computerized evaluation and re-education biofeedback (CERB) prototype to analyze hand grasp performances, and monitor the training effects on hand coordination for stroke patients with sensory disturbance and without motor deficiency. The CERB prototype was constructed to detect momentary pinch force modulation for 14 sub-acute and chronic stroke patients with sensory deficiency and 14 healthy controls. The other ten chronic stroke patients (ranges of stroke period: 6-60 months) were recruited to investigate the effects of 4-weeks computerized biofeedback treatments on the hand control ability. The biofeedback procedures provide visual and auditory cues to the participants when the interactive force of hand-to-object exceeded the target latitude in a pinch-up-holding task to trigger optimal motor strategy. Follow-up measurements were conducted one month after training. The hand sensibility, grip forces and results of hand functional tests were recorded and analyzed. The affected hands of the 14 predominant sensory stroke patients exhibited statistically significant elevation in the magnitude of peak pinch force (p = 0.033) in pinching and lifting-up tasks, and poor results for hand function tests (p = 0.005) than sound hands did. In addition, the sound hands of patients were less efficient in force modulation (p = 0.009) than the hands of healthy subjects were. Training with the biofeedback system produced significant improvements in grip force modulation (p = 0.020) and

  3. Clinical application of computerized evaluation and re-education biofeedback prototype for sensorimotor control of the hand in stroke patients

    Directory of Open Access Journals (Sweden)

    Hsu Hsiu-Yun

    2012-05-01

    Full Text Available Abstract Background Hemianaesthesia patients usually exhibit awkward and inefficient finger movements of the affected hands. Conventionally, most interventions emphasize the improvement of motor deficits, but rarely address sensory capability and sensorimotor control following stroke. Thus it is critical for stroke patients with sensory problems to incorporate appropriate strategies for dealing with sensory impairment, into traditional hand function rehabilitation programs. In this study, we used a custom-designed computerized evaluation and re-education biofeedback (CERB prototype to analyze hand grasp performances, and monitor the training effects on hand coordination for stroke patients with sensory disturbance and without motor deficiency. Methods The CERB prototype was constructed to detect momentary pinch force modulation for 14 sub-acute and chronic stroke patients with sensory deficiency and 14 healthy controls. The other ten chronic stroke patients (ranges of stroke period: 6–60 months were recruited to investigate the effects of 4-weeks computerized biofeedback treatments on the hand control ability. The biofeedback procedures provide visual and auditory cues to the participants when the interactive force of hand-to-object exceeded the target latitude in a pinch-up-holding task to trigger optimal motor strategy. Follow-up measurements were conducted one month after training. The hand sensibility, grip forces and results of hand functional tests were recorded and analyzed. Results The affected hands of the 14 predominant sensory stroke patients exhibited statistically significant elevation in the magnitude of peak pinch force (p = 0.033 in pinching and lifting-up tasks, and poor results for hand function tests (p = 0.005 than sound hands did. In addition, the sound hands of patients were less efficient in force modulation (p = 0.009 than the hands of healthy subjects were. Training with the biofeedback system produced

  4. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 65K ...

  5. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 66K ...

  6. Challenges in implementing electronic hand hygiene monitoring systems.

    Science.gov (United States)

    Conway, Laurie J

    2016-05-02

    Electronic hand hygiene (HH) monitoring systems offer the exciting prospect of a more precise, less biased measure of HH performance than direct observation. However, electronic systems are challenging to implement. Selecting a system that minimizes disruption to the physical infrastructure and to clinician workflow, and that fits with the organization's culture and budget, is challenging. Getting front-line workers' buy-in and addressing concerns about the accuracy of the system and how the data will be used are also difficult challenges. Finally, ensuring information from the system reaches front-line workers and is used by them to improve HH practice is a complex challenge. We describe these challenges in detail and suggests ways to overcome them. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  7. Acupuncture in subjects with cold hands sensation: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Seo, Jung-Chul; Lee, Hyun-jong; Kwak, Min-Ah; Park, Sung-Hoon; Shin, ImHee; Yun, Woo-Sung; Park, Kihyuk

    2014-09-04

    Cold hands sensation is a common disorder within the Korean population. Many Korean family physicians believe that it is a mild early manifestation of Raynaud's phenomenon (RP), or may be related to RP. RP is characterized by reversible digital vasospasm provoked by cold temperatures and/or emotional stress, and doctors often prescribe medications that are used in treatment of RP for subjects with cold hands. However, this has not shown a clear benefit, and these medications can cause unwanted side effects. It is also reported that traditional Korean medicine, including acupuncture, is widely used to treat cold hands, although the current level of evidence for this approach is also poor and to date, there have been no published randomized controlled clinical trials (RCTs) evaluating the efficacy and safety of acupuncture for cold hands. We have therefore designed a pilot RCT to obtain information for the design of a further full-scale trial. The proposed study is a five-week pilot RCT. A total of 14 subjects will be recruited and randomly allocated to two groups: an acupuncture plus medication group (experimental group) and a medication-only group (control group). All subjects will take nifedipine (5 mg once daily) and beraprost (20 mg three times daily) for three weeks. The experimental group will receive additional treatment with three acupuncture sessions per week for three weeks (nine sessions total). The primary outcome will be measured using a visual analogue scale. Secondary outcomes will be measured by blood perfusion in laser Doppler perfusion imaging of the hands, frequency and duration of episodes of cold hands, and heart rate variability. Assessments will be made at baseline and at one, three, and five weeks thereafter. This study will provide an indication of the feasibility and a clinical foundation for a future large-scale trial. This study was registered at Korean Clinical Research Information Service (CRIS) registry on 5 August 2013 with the

  8. Access to Waterless Hand Sanitizer Improves Student Hand Hygiene Behavior in Primary Schools in Nairobi, Kenya

    Science.gov (United States)

    Pickering, Amy J.; Davis, Jennifer; Blum, Annalise G.; Scalmanini, Jenna; Oyier, Beryl; Okoth, George; Breiman, Robert F.; Ram, Pavani K.

    2013-01-01

    Handwashing is difficult in settings with limited resources and water access. In primary schools within urban Kibera, Kenya, we investigated the impact of providing waterless hand sanitizer on student hand hygiene behavior. Two schools received a waterless hand sanitizer intervention, two schools received a handwashing with soap intervention, and two schools received no intervention. Hand cleaning behavior after toilet use was monitored for 2 months using structured observation. Hand cleaning after toileting was 82% at sanitizer schools (N = 2,507 toileting events), 38% at soap schools (N = 3,429), and 37% at control schools (N = 2,797). Students at sanitizer schools were 23% less likely to have observed rhinorrhea than control students (P = 0.02); reductions in student-reported gastrointestinal and respiratory illness symptoms were not statistically significant. Providing waterless hand sanitizer markedly increased student hand cleaning after toilet use, whereas the soap intervention did not. Waterless hand sanitizer may be a promising option to improve student hand cleansing behavior, particularly in schools with limited water access. PMID:23836575

  9. Simple Model-Free Controller for the Stabilization of Planetary Inverted Pendulum

    Directory of Open Access Journals (Sweden)

    Huanhuan Mai

    2012-01-01

    Full Text Available A simple model-free controller is presented for solving the nonlinear dynamic control problems. As an example of the problem, a planetary gear-type inverted pendulum (PIP is discussed. To control the inherently unstable system which requires real-time control responses, the design of a smart and simple controller is made necessary. The model-free controller proposed includes a swing-up controller part and a stabilization controller part; neither controller has any information about the PIP. Since the input/output scaling parameters of the fuzzy controller are highly sensitive, we use genetic algorithm (GA to obtain the optimal control parameters. The experimental results show the effectiveness and robustness of the present controller.

  10. The effect of improved hand hygiene on nosocomial MRSA control.

    Science.gov (United States)

    Marimuthu, Kalisvar; Pittet, Didier; Harbarth, Stephan

    2014-01-01

    The purpose of this review is to examine studies that have assessed the association between hand hygiene enhancement and methicillin-resistant Staphylococcus aureus (MRSA) rates and to explore controversies surrounding this association. Many studies have been published confirming the link between improved hand hygiene compliance and reduction in MRSA acquisition and infections, including bacteremia. These studies have also shown the cost-beneficial nature of these programmes. Despite considerable research some issues remain unanswered still, including the temporal relationship between hand hygiene enhancement strategies and decrease in MRSA rates, association between hand hygiene enhancement and MRSA-related surgical site infections, diminishing effect of hand hygiene compliance on MRSA rates after reaching a threshold and the role of instituting contact precautions in the setting of low MRSA rates and sufficient hand hygiene compliance. In conclusion, enhancement of hand hygiene compliance has been shown to reduce MRSA rates; however, some open issues warrant further investigation.

  11. Control-structure interaction in precision pointing servo loops

    Science.gov (United States)

    Spanos, John T.

    1989-01-01

    The control-structure interaction problem is addressed via stability analysis of a generic linear servo loop model. With the plant described by the rigid body mode and a single elastic mode, structural flexibility is categorized into one of three types: (1) appendage, (2) in-the-loop minimum phase, and (3) in-the-loop nonminimum phase. Closing the loop with proportional-derivative (PD) control action and introducing sensor roll-off dynamics in the feedback path, stability conditions are obtained. Trade studies are conducted with modal frequency, modal participation, modal damping, loop bandwidth, and sensor bandwidth treated as free parameters. Results indicate that appendage modes are most likely to produce instability if they are near the sensor rolloff, whereas in-the-loop modes are most dangerous near the loop bandwidth. The main goal of this paper is to provide a fundamental understanding of the control-structure interaction problem so that it may benefit the design of complex spacecraft and pointing system servo loops. In this framework, the JPL Pathfinder gimbal pointer is considered as an example.

  12. Toward the restoration of hand use to a paralyzed monkey: brain-controlled functional electrical stimulation of forearm muscles.

    Directory of Open Access Journals (Sweden)

    Eric A Pohlmeyer

    2009-06-01

    Full Text Available Loss of hand use is considered by many spinal cord injury survivors to be the most devastating consequence of their injury. Functional electrical stimulation (FES of forearm and hand muscles has been used to provide basic, voluntary hand grasp to hundreds of human patients. Current approaches typically grade pre-programmed patterns of muscle activation using simple control signals, such as those derived from residual movement or muscle activity. However, the use of such fixed stimulation patterns limits hand function to the few tasks programmed into the controller. In contrast, we are developing a system that uses neural signals recorded from a multi-electrode array implanted in the motor cortex; this system has the potential to provide independent control of multiple muscles over a broad range of functional tasks. Two monkeys were able to use this cortically controlled FES system to control the contraction of four forearm muscles despite temporary limb paralysis. The amount of wrist force the monkeys were able to produce in a one-dimensional force tracking task was significantly increased. Furthermore, the monkeys were able to control the magnitude and time course of the force with sufficient accuracy to track visually displayed force targets at speeds reduced by only one-third to one-half of normal. Although these results were achieved by controlling only four muscles, there is no fundamental reason why the same methods could not be scaled up to control a larger number of muscles. We believe these results provide an important proof of concept that brain-controlled FES prostheses could ultimately be of great benefit to paralyzed patients with injuries in the mid-cervical spinal cord.

  13. A robust internal control for high-precision DNA methylation analyses by droplet digital PCR.

    Science.gov (United States)

    Pharo, Heidi D; Andresen, Kim; Berg, Kaja C G; Lothe, Ragnhild A; Jeanmougin, Marine; Lind, Guro E

    2018-01-01

    Droplet digital PCR (ddPCR) allows absolute quantification of nucleic acids and has potential for improved non-invasive detection of DNA methylation. For increased precision of the methylation analysis, we aimed to develop a robust internal control for use in methylation-specific ddPCR. Two control design approaches were tested: (a) targeting a genomic region shared across members of a gene family and (b) combining multiple assays targeting different pericentromeric loci on different chromosomes. Through analyses of 34 colorectal cancer cell lines, the performance of the control assay candidates was optimized and evaluated, both individually and in various combinations, using the QX200™ droplet digital PCR platform (Bio-Rad). The best-performing control was tested in combination with assays targeting methylated CDO1 , SEPT9 , and VIM . A 4Plex panel consisting of EPHA3 , KBTBD4 , PLEKHF1 , and SYT10 was identified as the best-performing control. The use of the 4Plex for normalization reduced the variability in methylation values, corrected for differences in template amount, and diminished the effect of chromosomal aberrations. Positive Droplet Calling (PoDCall), an R-based algorithm for standardized threshold determination, was developed, ensuring consistency of the ddPCR results. Implementation of a robust internal control, i.e., the 4Plex, and an algorithm for automated threshold determination, PoDCall, in methylation-specific ddPCR increase the precision of DNA methylation analysis.

  14. Humanlike robot hands controlled by brain activity arouse illusion of ownership in operators

    Science.gov (United States)

    Alimardani, Maryam; Nishio, Shuichi; Ishiguro, Hiroshi

    2013-08-01

    Operators of a pair of robotic hands report ownership for those hands when they hold image of a grasp motion and watch the robot perform it. We present a novel body ownership illusion that is induced by merely watching and controlling robot's motions through a brain machine interface. In past studies, body ownership illusions were induced by correlation of such sensory inputs as vision, touch and proprioception. However, in the presented illusion none of the mentioned sensations are integrated except vision. Our results show that during BMI-operation of robotic hands, the interaction between motor commands and visual feedback of the intended motions is adequate to incorporate the non-body limbs into one's own body. Our discussion focuses on the role of proprioceptive information in the mechanism of agency-driven illusions. We believe that our findings will contribute to improvement of tele-presence systems in which operators incorporate BMI-operated robots into their body representations.

  15. An EEG/EOG-based hybrid brain-neural computer interaction (BNCI) system to control an exoskeleton for the paralyzed hand.

    Science.gov (United States)

    Soekadar, Surjo R; Witkowski, Matthias; Vitiello, Nicola; Birbaumer, Niels

    2015-06-01

    The loss of hand function can result in severe physical and psychosocial impairment. Thus, compensation of a lost hand function using assistive robotics that can be operated in daily life is very desirable. However, versatile, intuitive, and reliable control of assistive robotics is still an unsolved challenge. Here, we introduce a novel brain/neural-computer interaction (BNCI) system that integrates electroencephalography (EEG) and electrooculography (EOG) to improve control of assistive robotics in daily life environments. To evaluate the applicability and performance of this hybrid approach, five healthy volunteers (HV) (four men, average age 26.5 ± 3.8 years) and a 34-year-old patient with complete finger paralysis due to a brachial plexus injury (BPI) used EEG (condition 1) and EEG/EOG (condition 2) to control grasping motions of a hand exoskeleton. All participants were able to control the BNCI system (BNCI control performance HV: 70.24 ± 16.71%, BPI: 65.93 ± 24.27%), but inclusion of EOG significantly improved performance across all participants (HV: 80.65 ± 11.28, BPI: 76.03 ± 18.32%). This suggests that hybrid BNCI systems can achieve substantially better control over assistive devices, e.g., a hand exoskeleton, than systems using brain signals alone and thus may increase applicability of brain-controlled assistive devices in daily life environments.

  16. Use of alcohol hand sanitizer as an infection control strategy in an acute care facility.

    Science.gov (United States)

    Hilburn, Jessica; Hammond, Brian S; Fendler, Eleanor J; Groziak, Patricia A

    2003-04-01

    Nosocomial infections are a major problem in health care facilities, resulting in extended durations of care, substantial morbidity and mortality, and excess costs. Since alcohol gel hand sanitizers combine high immediate antimicrobial efficacy with ease of use, this study was carried out to determine the effect of the use of an alcohol gel hand sanitizer by caregivers on infection types and rates in an acute care facility. Patients were educated about the study through a poster on the unit, and teachable patients were given portable bottles of the alcohol hand gel for bedside use, along with an educational brochure explaining how and why to practice good hand hygiene. Infection rate and type data were collected in 1 unit of a 498-bed acute care facility for 16 months (February 2000 to May 2001). An alcohol gel hand sanitizer was provided and used by caregivers in the orthopedic surgical unit of the facility during this period. The primary infection types (more than 80%) found were urinary tract (UTI) and surgical site (SSI) infections. Infection types and rates for the unit during the period the alcohol hand sanitizer (intervention) was used were compared with the infection types and rates for the same unit when the alcohol hand sanitizer was not used (baseline); the results demonstrated a 36.1% decrease in infection rates for the 10-month period that the hand sanitizer was used. This study indicates that use of an alcohol gel hand sanitizer can decrease infection rates and provide an additional tool for an effective infection control program in acute care facilities.

  17. General Form of Model-Free Control Law and Convergence Analyzing

    Directory of Open Access Journals (Sweden)

    Xiuying Li

    2012-01-01

    Full Text Available The general form of model-free control law is introduced, and its convergence is analyzed. Firstly, the necessity to improve the basic form of model free control law is explained, and the functional combination method as the approach of improvement is presented. Then, a series of sufficient conditions of convergence are given. The analysis denotes that these conditions can be satisfied easily in the engineering practice.

  18. Offset Free Tracking Predictive Control Based on Dynamic PLS Framework

    Directory of Open Access Journals (Sweden)

    Jin Xin

    2017-10-01

    Full Text Available This paper develops an offset free tracking model predictive control based on a dynamic partial least square (PLS framework. First, state space model is used as the inner model of PLS to describe the dynamic system, where subspace identification method is used to identify the inner model. Based on the obtained model, multiple independent model predictive control (MPC controllers are designed. Due to the decoupling character of PLS, these controllers are running separately, which is suitable for distributed control framework. In addition, the increment of inner model output is considered in the cost function of MPC, which involves integral action in the controller. Hence, the offset free tracking performance is guaranteed. The results of an industry background simulation demonstrate the effectiveness of proposed method.

  19. The study of the precision and accuracy of quality control in DXA bone mineral densitometry

    International Nuclear Information System (INIS)

    Gong Jian; Xu Hao

    2005-01-01

    Objective: To study the precision and accuracy of quality control (QC) in dual-energy X-ray absorptiometry (DXA) bone mineral densitometry so as to raise the reliability and necessity of the results. Methods: 1) Short-term precision trial: 30 people and 30 SD male rats were chosen, and a precision trail was performed. Each people was scanned twice and reposited in next study. The precision and the least significant change (LSC) of each examinated region were calculated. The short-term precision trail of the rats was performed in the similar way. 2) Accuracy trial: measured the body phantom supplied by factor daily, and compared the results with real value, then calculated the accuracy and correction factor. A Shewhart chart was set up based on average values. Results: 1) People's coefficient of variation (CV) and LSC in the lumbar and proximal femur were 0.7%-2.2% and 0.018-0.048 g/cm 2 . Rats' whole body short-term precision was 0.9%. 2) The average accuracy of DXA densitometer was -0.81%, the correction factor was 0.992. The average bone mineral density measured in successive 25 d was 1.244 g/cm 2 , the standard deviation (SD) was 0.008. Conclusion: The precision and accuracy trail can help to get the information about the working state of the instrument and to analyze the measured results, and can effectively raise the reliability of the measure. (authors)

  20. Are we ready to move beyond the reductionist approach of classical synergy control?. Comment on "Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands" by Marco Santello et al.

    Science.gov (United States)

    Lacquaniti, Francesco; Ivanenko, Yuri P.; Zago, Myrka

    2016-07-01

    Starting from the classical concepts introduced by Sherrington [1] and considerably elaborated by Bernstein [2], much has been learned about motor synergies in the last several years. The contributions of the group funded by the European project ;The Hand Embodied; are remarkable in the field of biological and robotic control of the hand based on synergies, and they are reflected in this enjoyable review [3]. There, Santello et al. adopt Bernstein's definition of motor synergies as multiple elements working together towards a common goal, with the result that multiple degrees of freedom are controlled within a lower-dimensional space than the available number of dimensions.

  1. The retrieval efficiency test of descriptors and free vocabulary terms in INIS on-line search

    International Nuclear Information System (INIS)

    Ebinuma, Yukio; Takahashi, Satoko

    1981-01-01

    The test was done for 1) search topics with appropriate descriptors, 2) search topics with considerably broader descriptors, 3) search topics with no appropriate descriptors. As to (1) and (2) the retrieval efficiency was the same both on descriptor system and on keyword system (descriptors + free terms), and the search formulas were easily constructed. As to (3) the descriptor system ensured the recall ratio but decreased the precision ratio. On the other hand the keyword system made the construction of search formulas easy and resulted in good retrieval efficiency. The search system which is available both for full match method of descriptors and truncation method of keywords is desirable because each method can be selected according to the searcher's strategy and search topics. Free-term system seems unnecessary. (author)

  2. Comparative Geometrical Accuracy Investigations of Hand-Held 3d Scanning Systems - AN Update

    Science.gov (United States)

    Kersten, T. P.; Lindstaedt, M.; Starosta, D.

    2018-05-01

    Hand-held 3D scanning systems are increasingly available on the market from several system manufacturers. These systems are deployed for 3D recording of objects with different size in diverse applications, such as industrial reverse engineering, and documentation of museum exhibits etc. Typical measurement distances range from 0.5 m to 4.5 m. Although they are often easy-to-use, the geometric performance of these systems, especially the precision and accuracy, are not well known to many users. First geometrical investigations of a variety of diverse hand-held 3D scanning systems were already carried out by the Photogrammetry & Laser Scanning Lab of the HafenCity University Hamburg (HCU Hamburg) in cooperation with two other universities in 2016. To obtain more information about the accuracy behaviour of the latest generation of hand-held 3D scanning systems, HCU Hamburg conducted further comparative geometrical investigations using structured light systems with speckle pattern (Artec Spider, Mantis Vision PocketScan 3D, Mantis Vision F5-SR, Mantis Vision F5-B, and Mantis Vision F6), and photogrammetric systems (Creaform HandySCAN 700 and Shining FreeScan X7). In the framework of these comparative investigations geometrically stable reference bodies were used. The appropriate reference data was acquired by measurements with two structured light projection systems (AICON smartSCAN and GOM ATOS I 2M). The comprehensive test results of the different test scenarios are presented and critically discussed in this contribution.

  3. Precision natural SUSY at CEPC, FCC-ee, and ILC

    International Nuclear Information System (INIS)

    Fan, JiJi; Reece, Matthew; Wang, Lian-Tao

    2015-01-01

    Testing the idea of naturalness is and will continue to be one of the most important goals of high energy physics experiments. It will play a central role in the physics program of future colliders. In this paper, we present projections of the reach of natural SUSY at future lepton colliders: CEPC, FCC-ee and ILC. We focus on the observables which give the strongest reach, the electroweak precision observables (for left-handed stops), and Higgs to gluon and photon decay rates (for both left- and right-handed stops). There is a “blind spot” when the stop mixing parameter X t is approximately equal to the average stop mass. We argue that in natural scenarios, bounds on the heavy Higgs bosons from tree-level mixing effects that modify the hbb̄ coupling together with bounds from b→sγ play a complementary role in probing the blind spot region. For specific natural SUSY scenarios such as folded SUSY in which the top partners do not carry Standard Model color charges, electroweak precision observables could be the most sensitive probe. In all the scenarios discussed in this paper, the combined set of precision measurements will probe down to a few percent in fine-tuning.

  4. Repeatability of grasp recognition for robotic hand prosthesis control based on sEMG data.

    Science.gov (United States)

    Palermo, Francesca; Cognolato, Matteo; Gijsberts, Arjan; Muller, Henning; Caputo, Barbara; Atzori, Manfredo

    2017-07-01

    Control methods based on sEMG obtained promising results for hand prosthetics. Control system robustness is still often inadequate and does not allow the amputees to perform a large number of movements useful for everyday life. Only few studies analyzed the repeatability of sEMG classification of hand grasps. The main goals of this paper are to explore repeatability in sEMG data and to release a repeatability database with the recorded experiments. The data are recorded from 10 intact subjects repeating 7 grasps 12 times, twice a day for 5 days. The data are publicly available on the Ninapro web page. The analysis for the repeatability is based on the comparison of movement classification accuracy in several data acquisitions and for different subjects. The analysis is performed using mean absolute value and waveform length features and a Random Forest classifier. The accuracy obtained by training and testing on acquisitions at different times is on average 27.03% lower than training and testing on the same acquisition. The results obtained by training and testing on different acquisitions suggest that previous acquisitions can be used to train the classification algorithms. The inter-subject variability is remarkable, suggesting that specific characteristics of the subjects can affect repeatibility and sEMG classification accuracy. In conclusion, the results of this paper can contribute to develop more robust control systems for hand prostheses, while the presented data allows researchers to test repeatability in further analyses.

  5. Time response model of ER fluids for precision control of motors

    Energy Technology Data Exchange (ETDEWEB)

    Koyanagi, Ken' ichi [Toyama Prefectural University, 5180 Kurokawa, Imizu, Toyama (Japan)], E-mail: koyanagi@pu-toyama.ac.jp

    2009-02-01

    For improvement of control performance or new control demands of mechatronics devices using particle type ER fluids, it will be needed to further investigate a response time of the fluids. It is commonly said around 5-mili seconds, however, the formula structure of that delay has not been clear. This study aims to develop a functional damper (attenuators), that can control its viscous characteristics in real time using ER fluids as its working fluid. ER dampers are useful to accomplish high precision positioning not to prevent high speed movement of the motor. To realize the functional damper that can be manipulated according to situations or tasks, the modeling and control of ER fluids are necessary. This paper investigates time delay affects of ER fluids and makes an in-depth dynamic model of the fluid by utilizing simulation and experiment. The mathematical model has a dead-time and first ordered delays of the fluid and the high voltage amplifier for the fluid.

  6. The Future of Precision Medicine in Oncology.

    Science.gov (United States)

    Millner, Lori M; Strotman, Lindsay N

    2016-09-01

    Precision medicine in oncology focuses on identifying which therapies are most effective for each patient based on genetic characterization of the cancer. Traditional chemotherapy is cytotoxic and destroys all cells that are rapidly dividing. The foundation of precision medicine is targeted therapies and selecting patients who will benefit most from these therapies. One of the newest aspects of precision medicine is liquid biopsy. A liquid biopsy includes analysis of circulating tumor cells, cell-free nucleic acid, or exosomes obtained from a peripheral blood draw. These can be studied individually or in combination and collected serially, providing real-time information as a patient's cancer changes. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Combined analysis of cortical (EEG) and nerve stump signals improves robotic hand control.

    Science.gov (United States)

    Tombini, Mario; Rigosa, Jacopo; Zappasodi, Filippo; Porcaro, Camillo; Citi, Luca; Carpaneto, Jacopo; Rossini, Paolo Maria; Micera, Silvestro

    2012-01-01

    Interfacing an amputee's upper-extremity stump nerves to control a robotic hand requires training of the individual and algorithms to process interactions between cortical and peripheral signals. To evaluate for the first time whether EEG-driven analysis of peripheral neural signals as an amputee practices could improve the classification of motor commands. Four thin-film longitudinal intrafascicular electrodes (tf-LIFEs-4) were implanted in the median and ulnar nerves of the stump in the distal upper arm for 4 weeks. Artificial intelligence classifiers were implemented to analyze LIFE signals recorded while the participant tried to perform 3 different hand and finger movements as pictures representing these tasks were randomly presented on a screen. In the final week, the participant was trained to perform the same movements with a robotic hand prosthesis through modulation of tf-LIFE-4 signals. To improve the classification performance, an event-related desynchronization/synchronization (ERD/ERS) procedure was applied to EEG data to identify the exact timing of each motor command. Real-time control of neural (motor) output was achieved by the participant. By focusing electroneurographic (ENG) signal analysis in an EEG-driven time window, movement classification performance improved. After training, the participant regained normal modulation of background rhythms for movement preparation (α/β band desynchronization) in the sensorimotor area contralateral to the missing limb. Moreover, coherence analysis found a restored α band synchronization of Rolandic area with frontal and parietal ipsilateral regions, similar to that observed in the opposite hemisphere for movement of the intact hand. Of note, phantom limb pain (PLP) resolved for several months. Combining information from both cortical (EEG) and stump nerve (ENG) signals improved the classification performance compared with tf-LIFE signals processing alone; training led to cortical reorganization and

  8. Post-stroke Rehabilitation Training with a Motor-Imagery-Based Brain-Computer Interface (BCI-Controlled Hand Exoskeleton: A Randomized Controlled Multicenter Trial

    Directory of Open Access Journals (Sweden)

    Alexander A. Frolov

    2017-07-01

    Full Text Available Repeated use of brain-computer interfaces (BCIs providing contingent sensory feedback of brain activity was recently proposed as a rehabilitation approach to restore motor function after stroke or spinal cord lesions. However, there are only a few clinical studies that investigate feasibility and effectiveness of such an approach. Here we report on a placebo-controlled, multicenter clinical trial that investigated whether stroke survivors with severe upper limb (UL paralysis benefit from 10 BCI training sessions each lasting up to 40 min. A total of 74 patients participated: median time since stroke is 8 months, 25 and 75% quartiles [3.0; 13.0]; median severity of UL paralysis is 4.5 points [0.0; 30.0] as measured by the Action Research Arm Test, ARAT, and 19.5 points [11.0; 40.0] as measured by the Fugl-Meyer Motor Assessment, FMMA. Patients in the BCI group (n = 55 performed motor imagery of opening their affected hand. Motor imagery-related brain electroencephalographic activity was translated into contingent hand exoskeleton-driven opening movements of the affected hand. In a control group (n = 19, hand exoskeleton-driven opening movements of the affected hand were independent of brain electroencephalographic activity. Evaluation of the UL clinical assessments indicated that both groups improved, but only the BCI group showed an improvement in the ARAT's grasp score from 0 [0.0; 14.0] to 3.0 [0.0; 15.0] points (p < 0.01 and pinch scores from 0.0 [0.0; 7.0] to 1.0 [0.0; 12.0] points (p < 0.01. Upon training completion, 21.8% and 36.4% of the patients in the BCI group improved their ARAT and FMMA scores respectively. The corresponding numbers for the control group were 5.1% (ARAT and 15.8% (FMMA. These results suggests that adding BCI control to exoskeleton-assisted physical therapy can improve post-stroke rehabilitation outcomes. Both maximum and mean values of the percentage of successfully decoded imagery-related EEG activity, were higher

  9. Perspectives of precision agriculture in a broader policy context

    DEFF Research Database (Denmark)

    Lind, Kim Martin Hjorth; Pedersen, Søren Marcus

    2017-01-01

    that in a precise and targeted approach reduce resource use and increase yield. Furthermore, the growing demand for higher value food products in terms of health and quality require traceability and information about production processes and resource use, which also correspond with the possibilities offered...... by precision agriculture technology. The general movement towards higher integration in food supply chains is a natural extension of the requirements for traceability and product information, which are integral parts of precision agriculture.......Agriculture is faced with contrasting requirements from the broader society. On the one hand, agriculture needs to expand production to be able to feed a growing global population. Furthermore, the developing bio-economy requires agriculture to produce for a range of non-food objectives such as bio...

  10. [Precision and personalized medicine].

    Science.gov (United States)

    Sipka, Sándor

    2016-10-01

    The author describes the concept of "personalized medicine" and the newly introduced "precision medicine". "Precision medicine" applies the terms of "phenotype", "endotype" and "biomarker" in order to characterize more precisely the various diseases. Using "biomarkers" the homogeneous type of a disease (a "phenotype") can be divided into subgroups called "endotypes" requiring different forms of treatment and financing. The good results of "precision medicine" have become especially apparent in relation with allergic and autoimmune diseases. The application of this new way of thinking is going to be necessary in Hungary, too, in the near future for participants, controllers and financing boards of healthcare. Orv. Hetil., 2016, 157(44), 1739-1741.

  11. Model Predictive Control for Offset-Free Reference Tracking

    Czech Academy of Sciences Publication Activity Database

    Belda, Květoslav

    2016-01-01

    Roč. 5, č. 1 (2016), s. 8-13 ISSN 1805-3386 Institutional support: RVO:67985556 Keywords : offset-free reference tracking * predictive control * ARX model * state-space model * multi-input multi-output system * robotic system * mechatronic system Subject RIV: BC - Control Systems Theory http://library.utia.cas.cz/separaty/2016/AS/belda-0458355.pdf

  12. The alien hand sign. Localization, lateralization and recovery.

    Science.gov (United States)

    Goldberg, G; Bloom, K K

    1990-10-01

    The alien hand sign was first described by Brion and Jedynak as a "feeling of estrangement between the patient and one of his hands." The affected hand frequently shows a grasp reflex and an instinctive grasp reaction as well as elements of what Denny-Brown referred to as a "magnetic apraxia" associated with frontal lobe damage. Most notably, however, the affected hand is observed to perform apparently purposive behaviors that are perceived as being outside the volitional control of the patient. The patients interpret the behavior of their own affected limb as being controlled by an external agent. They do not feel that they are initiating or controlling the behavior of the hand and often express dismay at the hand's "extravolitional" activity. The patients attempt to control behavior of the alien hand with the unimpaired hand by forcibly restraining the affected limb, an act that may be termed "self-restriction." In this paper, we report an additional four cases of alien hand sign in right-handed subjects: two involving the right hand and two involving the left hand. In each case, the clinical findings were associated with extensive unilateral damage of the medial frontal cortex of the hemisphere contralateral to the affected hand. Furthermore, the alien movement gradually disappears over the course of 6-12 months after the stroke. These clinical case studies are presented and discussed in the context of the "dual premotoer systems hypothesis," an anatomicophysiological model that proposes that action is organized by two separate but interactive premotor brain systems corresponding to evolutionarily defined medial and lateral cortical moieties. It is hypothesized that the alien mode behavior results from unconstrained activity of the lateral premotor system in the damaged hemisphere. The residual volitional control in the limb occurs through the activity of the intact medial premotor system of the ipsilateral hemisphere. Recovery may occur through extension of

  13. Bifurcation-free design method of pulse energy converter controllers

    International Nuclear Information System (INIS)

    Kolokolov, Yury; Ustinov, Pavel; Essounbouli, Najib; Hamzaoui, Abdelaziz

    2009-01-01

    In this paper, a design method of pulse energy converter (PEC) controllers is proposed. This method develops a classical frequency domain design, based on the small signal modeling, by means of an addition of a nonlinear dynamics analysis stage. The main idea of the proposed method consists in fact that the PEC controller, designed with an application of the small signal modeling, is tuned after with taking into the consideration an essentially nonlinear nature of the PEC that makes it possible to avoid bifurcation phenomena in the PEC dynamics at the design stage (bifurcation-free design). Also application of the proposed method allows an improvement of the designed controller performance. The application of this bifurcation-free design method is demonstrated on an example of the controller design of direct current-direct current (DC-DC) buck converter with an input electromagnetic interference filter.

  14. Closed-loop control of spinal cord stimulation to restore hand function after paralysis

    Directory of Open Access Journals (Sweden)

    Jonas B Zimmermann

    2014-05-01

    Full Text Available As yet, no cure exists for upper-limb paralysis resulting from the damage to motor pathways after spinal cord injury or stroke. Recently, neural activity from the motor cortex of paralyzed individuals has been used to control the movements of a robot arm but restoring function to patients’ actual limbs remains a considerable challenge. Previously we have shown that electrical stimulation of the cervical spinal cord in anesthetized monkeys can elicit functional upper-limb movements like reaching and grasping. Here we show that stimulation can be controlled using cortical activity in awake animals to bypass disruption of the corticospinal system, restoring their ability to perform a simple upper-limb task. Monkeys were trained to grasp and pull a spring-loaded handle. After temporary paralysis of the hand was induced by reversible inactivation of primary motor cortex using muscimol, grasp-related single-unit activity from the ventral premotor cortex was converted into stimulation patterns delivered in real-time to the cervical spinal grey matter. During periods of closed-loop stimulation, task-modulated electromyogram, movement amplitude and task success rate were improved relative to interleaved control periods without stimulation. In some sessions, single motor unit activity from weakly active muscles was also used successfully to control stimulation. These results are the first use of a neural prosthesis to improve the hand function of primates after motor cortex disruption, and demonstrate the potential for closed-loop cortical control of spinal cord stimulation to reanimate paralyzed limbs.

  15. Precision metabolic engineering: The design of responsive, selective, and controllable metabolic systems.

    Science.gov (United States)

    McNerney, Monica P; Watstein, Daniel M; Styczynski, Mark P

    2015-09-01

    Metabolic engineering is generally focused on static optimization of cells to maximize production of a desired product, though recently dynamic metabolic engineering has explored how metabolic programs can be varied over time to improve titer. However, these are not the only types of applications where metabolic engineering could make a significant impact. Here, we discuss a new conceptual framework, termed "precision metabolic engineering," involving the design and engineering of systems that make different products in response to different signals. Rather than focusing on maximizing titer, these types of applications typically have three hallmarks: sensing signals that determine the desired metabolic target, completely directing metabolic flux in response to those signals, and producing sharp responses at specific signal thresholds. In this review, we will first discuss and provide examples of precision metabolic engineering. We will then discuss each of these hallmarks and identify which existing metabolic engineering methods can be applied to accomplish those tasks, as well as some of their shortcomings. Ultimately, precise control of metabolic systems has the potential to enable a host of new metabolic engineering and synthetic biology applications for any problem where flexibility of response to an external signal could be useful. Copyright © 2015 International Metabolic Engineering Society. Published by Elsevier Inc. All rights reserved.

  16. [Impact of the new smoke-free legislation (law 42/2010) on levels of second-hand smoke in hospitality venues].

    Science.gov (United States)

    Córdoba, Rodrigo; Nerín, Isabel; Galindo, Virginia; Alayeto, Carmen; Villaverde-Royo, M A Victoria; Sanz, Concepción

    2013-01-01

    To evaluate pollution by second-hand smoke in a sample of hospitality venues before and after the implementation of smoke-free legislation. A cross sectional, before-after study was conducted in 2008 and 2011 after the total ban. A SidePack Aerosol monitor was used both inside and outside the hospitality venues to measure fine breathable particles (PM2.5). A total of 43 places with pre- and post-legislation measurements were included. The median indoor pollution in hospitality venues was 204.2μg/m(3) in 2008 and 18.82μg/m(3) in 2011; the average outdoor PM2.5 concentration was 47.04μg/m(3) in 2008 and 18.82μg/m(3) in 2011. Pollution was higher in bars and cafeterias, followed by pubs and discos. Before the law was implemented, pollution was 4.34 times higher indoors than outdoors; in 2011 the average indoor PM2.5 concentration decreased by 90.88%. Only a complete ban is able to protect workers and customers against the health risks of second-hand smoke exposure. Copyright © 2011 SESPAS. Published by Elsevier Espana. All rights reserved.

  17. Octopuses use a human-like strategy to control precise point-to-point arm movements.

    Science.gov (United States)

    Sumbre, Germán; Fiorito, Graziano; Flash, Tamar; Hochner, Binyamin

    2006-04-18

    One of the key problems in motor control is mastering or reducing the number of degrees of freedom (DOFs) through coordination. This problem is especially prominent with hyper-redundant limbs such as the extremely flexible arm of the octopus. Several strategies for simplifying these control problems have been suggested for human point-to-point arm movements. Despite the evolutionary gap and morphological differences, humans and octopuses evolved similar strategies when fetching food to the mouth. To achieve this precise point-to-point-task, octopus arms generate a quasi-articulated structure based on three dynamic joints. A rotational movement around these joints brings the object to the mouth . Here, we describe a peripheral neural mechanism-two waves of muscle activation propagate toward each other, and their collision point sets the medial-joint location. This is a remarkably simple mechanism for adjusting the length of the segments according to where the object is grasped. Furthermore, similar to certain human arm movements, kinematic invariants were observed at the joint level rather than at the end-effector level, suggesting intrinsic control coordination. The evolutionary convergence to similar geometrical and kinematic features suggests that a kinematically constrained articulated limb controlled at the level of joint space is the optimal solution for precise point-to-point movements.

  18. Advanced Attitude Control af Pico Sized Satellites

    DEFF Research Database (Denmark)

    Larsen, Jesper A.; Amini, Rouzbeh; Izadi-Zamanabadi, Roozbeh

    2005-01-01

    accuracy of better than 5 degrees. Cost, size, weight and power requirements, on the other hand, impose selecting relative simple sensors and actuators which leads to an attitude control requirement of less than 1 degree. This precision is obtained by a combination of magnetorquers and momentum wheels...

  19. A synergy-driven approach to a myoelectric hand.

    Science.gov (United States)

    Godfrey, S B; Ajoudani, A; Catalano, M; Grioli, G; Bicchi, A

    2013-06-01

    In this paper, we present the Pisa/IIT SoftHand with myoelectric control as a synergy-driven approach for a prosthetic hand. Commercially available myoelectric hands are more expensive, heavier, and less robust than their body-powered counterparts; however, they can offer greater freedom of motion and a more aesthetically pleasing appearance. The Pisa/IIT SoftHand is built on the motor control principle of synergies through which the immense complexity of the hand is simplified into distinct motor patterns. As the SoftHand grasps, it follows a synergistic path with built-in flexibility to allow grasping of a wide variety of objects with a single motor. Here we test, as a proof-of-concept, 4 myoelectric controllers: a standard controller in which the EMG signal is used only as a position reference, an impedance controller that determines both position and stiffness references from the EMG input, a standard controller with vibrotactile force feedback, and finally a combined vibrotactile-impedance (VI) controller. Four healthy subjects tested the control algorithms by grasping various objects. All controllers were sufficient for basic grasping, however the impedance and vibrotactile controllers reduced the physical and cognitive load on the user, while the combined VI mode was the easiest to use of the four. While these results need to be validated with amputees, they suggest a low-cost, robust hand employing hardware-based synergies is a viable alternative to traditional myoelectric prostheses.

  20. Control of an Autonomous Vehicle for Registration of Weed and Crop in Precision Agriculture

    DEFF Research Database (Denmark)

    Nielsen, Kirsten Mølgaard; Andersen, Palle; Pedersen, Tom Søndergaard

    2002-01-01

    The paper describes the development of an autonomous electrical vehicle to be used for weed mapping in precision agriculture with special focus on the conceptual framework of the control system. The lowest layer of the control system is the propulsion and steering control, the second layer...... coordinates the movements of the wheel units, the third layer is path execution and perception and the upper layer performs planning and reasoning. The control system is implemented on an autonomous vehicle. The vehicle has been tested for path following and position accuracy. Based on the results a new...... vehicle is under construction....

  1. Avaliação tomográfica do posicionamento de parafusos pediculares em deformidades na coluna torácica e lombar introduzidos com base na técnica "free hand" Evaluación tomográfica de la colocación de tornillos pediculares en deformidades de la columna torácica y lumbar, introducidos con base en la técnica "free hand" Tomographic evaluation of the placement of pedicle screws used in deformities of the thoracic and lumbar spine based on the "free hand" technique

    Directory of Open Access Journals (Sweden)

    Dante Bernardes Giubilei

    2011-01-01

    Full Text Available OBJETIVO: Avaliar o posicionamento de parafusos pediculares aplicados em vértebras da coluna torácica e lombar em pacientes portadores de escolioses, introduzidos pela técnica "free hand". MÉTODOS: Avaliação de quinze tomografias computadorizadas de 284 parafusos pediculares em 15 pacientes (sete homens e oito mulheres, com idade entre 12 e 39 anos (média de 16,7 anos com escoliose. Os parafusos foram inseridos de T2 a S1 para as seguintes afecções: duas escolioses congênitas e 13 escolioses neuromusculares, visando avaliar o posicionamento dos parafusos com relação às paredes dos pedículos. RESULTADOS: Em relação às corticais do pedículo, 244 parafusos (86% foram posicionados entre as corticais ou apenas as tocaram. Houve lesão da cortical lateral em 16 parafusos e lesão da cortical medial em 13 parafusos, sendo maior o número de violações nas vértebras torácicas. CONCLUSÃO: O uso de parafusos pediculares na instrumentação de vértebras torácicas e lombares nas escolioses mostrou -se segura e efetiva quando aplicado em diferentes níveis com a técnica "free hand''. Nas vértebras torácicas as violações da cortical pedicular foram mais frequentes, mas não prejudicaram a estabilidade da fixação e não lesaram estruturas neurais, vasculares e viscerais.OBJETIVO: Evaluar la colocación de tornillos pediculares utilizados en las vértebras de la columna torácica y lumbar en pacientes con escoliosis, introducidos mediante la técnica "free hand". MÉTODOS: Se evaluaron quince tomografías computadorizadas de 284 tornillos pediculares en 15 pacientes (siete hombres y ocho mujeres, de edades comprendidas entre 12 y 39 años (promedio de 16,7 años, que tenían escoliosis. Los tornillos se insertaron desde T2 a S1, siendo dos escoliosis congénitas y 13 escoliosis neuromusculares; se analizó la colocación de los tornillos en relación a las paredes de los pedículos. RESULTADOS: Cuanto a las corticales del ped

  2. On the notion of free will in the Free Will Theorem

    Science.gov (United States)

    Landsman, Klaas

    2017-02-01

    The (Strong) Free Will Theorem (FWT) of Conway and Kochen (2009) on the one hand follows from uncontroversial parts of modern physics and elementary mathematical and logical reasoning, but on the other hand seems predicated on an undefined notion of free will (allowing physicists to "freely choose" the settings of their experiments). This makes the theorem philosophically vulnerable, especially if it is construed as a proof of indeterminism or even of libertarian free will (as Conway & Kochen suggest). However, Cator and Landsman (Foundations of Physics 44, 781-791, 2014) previously gave a reformulation of the FWT that does not presuppose indeterminism, but rather assumes a mathematically specific form of such "free choices" even in a deterministic world (based on a non-probabilistic independence assumption). In the present paper, which is a philosophical sequel to the one just mentioned, I argue that the concept of free will used in the latter version of the FWT is essentially the one proposed by Lewis (1981), also known as 'local miracle compatibilism' (of which I give a mathematical interpretation that might be of some independent interest also beyond its application to the FWT). As such, the (reformulated) FWT in my view challenges compatibilist free will à la Lewis (albeit in a contrived way via bipartite EPR-type experiments), falling short of supporting libertarian free will.

  3. Precision medicine for advanced prostate cancer.

    Science.gov (United States)

    Mullane, Stephanie A; Van Allen, Eliezer M

    2016-05-01

    Precision cancer medicine, the use of genomic profiling of patient tumors at the point-of-care to inform treatment decisions, is rapidly changing treatment strategies across cancer types. Precision medicine for advanced prostate cancer may identify new treatment strategies and change clinical practice. In this review, we discuss the potential and challenges of precision medicine in advanced prostate cancer. Although primary prostate cancers do not harbor highly recurrent targetable genomic alterations, recent reports on the genomics of metastatic castration-resistant prostate cancer has shown multiple targetable alterations in castration-resistant prostate cancer metastatic biopsies. Therapeutic implications include targeting prevalent DNA repair pathway alterations with PARP-1 inhibition in genomically defined subsets of patients, among other genomically stratified targets. In addition, multiple recent efforts have demonstrated the promise of liquid tumor profiling (e.g., profiling circulating tumor cells or cell-free tumor DNA) and highlighted the necessary steps to scale these approaches in prostate cancer. Although still in the initial phase of precision medicine for prostate cancer, there is extraordinary potential for clinical impact. Efforts to overcome current scientific and clinical barriers will enable widespread use of precision medicine approaches for advanced prostate cancer patients.

  4. Development of cryogenic free-piston reciprocating expander utilizing phase controller

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Jeong Min; Park, Ji Ho; Kim, Kyung Joong; Jeong, Sang Kwon [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2016-06-15

    A free-piston reciprocating expander is a device which operates without any mechanical linkage to a stationary part. Since the motion of the floating piston is only controlled by the pressure difference at two ends of the piston, this kind of expander may indispensably require a sophisticated active control system equipped with multiple valves and reservoirs. In this paper, we have suggested a novel design that can further reduce complexity of the previously developed cryogenic free-piston expander configuration. It is a simple replacement of both multiple valves and reservoirs by a combination of an orifice valve and a reservoir. The functional characteristic of the integrated orifice-reservoir configuration is similar to that of a phase controller applied in a pulse tube refrigerator so that we designate the one as a phase controller. Depending on the orifice valve size in the phase controller, the different PV work which affects the expander performance is generated. The numerical model of this unique free-piston reciprocating expander utilizing a phase controller is established to understand and analyze quantitatively the performance variation of the expander under different valve timing and orifice valve size. The room temperature experiments are carried out to examine the performance of this newly developed cryogenic expander.

  5. Development of cryogenic free-piston reciprocating expander utilizing phase controller

    International Nuclear Information System (INIS)

    Cha, Jeong Min; Park, Ji Ho; Kim, Kyung Joong; Jeong, Sang Kwon

    2016-01-01

    A free-piston reciprocating expander is a device which operates without any mechanical linkage to a stationary part. Since the motion of the floating piston is only controlled by the pressure difference at two ends of the piston, this kind of expander may indispensably require a sophisticated active control system equipped with multiple valves and reservoirs. In this paper, we have suggested a novel design that can further reduce complexity of the previously developed cryogenic free-piston expander configuration. It is a simple replacement of both multiple valves and reservoirs by a combination of an orifice valve and a reservoir. The functional characteristic of the integrated orifice-reservoir configuration is similar to that of a phase controller applied in a pulse tube refrigerator so that we designate the one as a phase controller. Depending on the orifice valve size in the phase controller, the different PV work which affects the expander performance is generated. The numerical model of this unique free-piston reciprocating expander utilizing a phase controller is established to understand and analyze quantitatively the performance variation of the expander under different valve timing and orifice valve size. The room temperature experiments are carried out to examine the performance of this newly developed cryogenic expander

  6. Free-range pork: Innovation and control of a new credence good

    DEFF Research Database (Denmark)

    Philipsen, Kristian; Andersen, Esben Sloth

    -range pork should be analysed as a "credence good". In this way a whole set of problems related to production and sale of this kind of pork becomes clear. 2. The problem of evaluating a credence good is intensified in the case of free-range pork, because the responsibility for the credence quality is divided...... among a large number of parties, and the fact that there is no common "standard" or "definition" of what is meant by free-range pork. Thi aggravates the control aspect of free-range pork. This report focuses on this point. 3. The study's empirical basis is three cases, one Dutch and two Danish, about...... withdrawn from the Danish free-range pork market. 8. The Dutch system with an independent control organisation may be a paradigm or a standard for establishing an inspection system for credence goods. The Dutch system, therefore, seems to be more advanced than the other control systems with regard...

  7. Effect of hand sanitizer location on hand hygiene compliance.

    Science.gov (United States)

    Cure, Laila; Van Enk, Richard

    2015-09-01

    Hand hygiene is the most important intervention to prevent infection in hospitals. Health care workers should clean their hands at least before and after contact with patients. Hand sanitizer dispensers are important to support hand hygiene because they can be made available throughout hospital units. The aim of this study was to determine whether the usability of sanitizer dispensers correlates with compliance of staff in using the sanitizer in a hospital. This study took place in a Midwest, 404-bed, private, nonprofit community hospital with 15 inpatient care units in addition to several ambulatory units. The usability and standardization of sanitizers in 12 participating inpatient units were evaluated. The hospital measured compliance of staff with hand hygiene as part of their quality improvement program. Data from 2010-2012 were analyzed to measure the relationship between compliance and usability using mixed-effects logistic regression models. The total usability score (P = .0046), visibility (P = .003), and accessibility of the sanitizer on entrance to the patient room (P = .00055) were statistically associated with higher observed compliance rates. Standardization alone showed no significant impact on observed compliance (P = .37). Hand hygiene compliance can be influenced by visibility and accessibility of dispensers. The sanitizer location should be part of multifaceted interventions to improve hand hygiene. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  8. Successful hand replantation in a seafarer after long-distance helicopter evacuation. A case report.

    Science.gov (United States)

    Fernandez-Palacios, Javier; Duque, Orlando Garcia; Benitez, Ruben Alvarado; Bolanos, Luis Fabelo; Calderin, Jose Guterrez

    2009-01-01

    After sustaining a clean-cut mid-carpal hand amputation on a tanker 120 miles north of Lanzarote, a 28- -year-old seafarer was evacuated by helicopter to a microsurgical unit in Gran Canaria. The amputated hand was cooled according to precise instructions. The 6-hour flight time included two refuelling stops and transfer time. The hand had been revascularized thirteen hours after the accident and was still well circulated at repatriation 3 weeks later.

  9. Antiseptic Effect of Conventional Povidone-Iodine Scrub, Chlorhexidine Scrub, and Waterless Hand Rub in a Surgical Room: A Randomized Controlled Trial.

    Science.gov (United States)

    Tsai, Jui-Chen; Lin, Yen-Kuang; Huang, Yen-Jung; Loh, El-Wui; Wen, Hsiao-Yun; Wang, Chia-Hui; Tsai, Yin-Tai; Hsieh, Wen-Shyang; Tam, Ka-Wai

    2017-04-01

    OBJECTIVE Effective perioperative hand antisepsis is crucial for the safety of patients and medical staff in surgical rooms. The antimicrobial effectiveness of different antiseptic methods, including conventional hand scrubs and waterless hand rubs, has not been well evaluated. DESIGN, SETTING, AND PARTICIPANTS A randomized controlled trial was conducted to investigate the effectiveness of the 3 antiseptic methods among surgical staff of Taipei Medical University-Shuang Ho Hospital. For each method used, a group of 80 participants was enrolled. INTERVENTION Surgical hand cleansing with conventional 10% povidone-iodine scrub, conventional 4% chlorhexidine scrub, or waterless hand rub (1% chlorhexidine gluconate and 61% ethyl alcohol). RESULTS Colony-forming unit (CFU) counts were collected using the hand imprinting method before and after disinfection and after surgery. After surgical hand disinfection, the mean CFU counts of the conventional chlorhexidine (0.5±0.2, Pantiseptic method (P=.0036), but not other variables, predicted the mean CFU count. CONCLUSIONS Conventional chlorhexidine scrub and waterless hand rub were superior to a conventional povidone-iodine product in bacterial inhibition. We recommend using conventional chlorhexidine scrub as a standard method for perioperative hand antisepsis. Waterless hand rub may be used if the higher cost is affordable. Infect Control Hosp Epidemiol 2017;38:417-422.

  10. Flight control and landing precision in the nocturnal bee Megalopta is robust to large changes in light intensity.

    Science.gov (United States)

    Baird, Emily; Fernandez, Diana C; Wcislo, William T; Warrant, Eric J

    2015-01-01

    Like their diurnal relatives, Megalopta genalis use visual information to control flight. Unlike their diurnal relatives, however, they do this at extremely low light intensities. Although Megalopta has developed optical specializations to increase visual sensitivity, theoretical studies suggest that this enhanced sensitivity does not enable them to capture enough light to use visual information to reliably control flight in the rainforest at night. It has been proposed that Megalopta gain extra sensitivity by summing visual information over time. While enhancing the reliability of vision, this strategy would decrease the accuracy with which they can detect image motion-a crucial cue for flight control. Here, we test this temporal summation hypothesis by investigating how Megalopta's flight control and landing precision is affected by light intensity and compare our findings with the results of similar experiments performed on the diurnal bumblebee Bombus terrestris, to explore the extent to which Megalopta's adaptations to dim light affect their precision. We find that, unlike Bombus, light intensity does not affect flight and landing precision in Megalopta. Overall, we find little evidence that Megalopta uses a temporal summation strategy in dim light, while we find strong support for the use of this strategy in Bombus.

  11. Unconstrained and contactless hand geometry biometrics.

    Science.gov (United States)

    de-Santos-Sierra, Alberto; Sánchez-Ávila, Carmen; Del Pozo, Gonzalo Bailador; Guerra-Casanova, Javier

    2011-01-01

    This paper presents a hand biometric system for contact-less, platform-free scenarios, proposing innovative methods in feature extraction, template creation and template matching. The evaluation of the proposed method considers both the use of three contact-less publicly available hand databases, and the comparison of the performance to two competitive pattern recognition techniques existing in literature: namely support vector machines (SVM) and k-nearest neighbour (k-NN). Results highlight the fact that the proposed method outcomes existing approaches in literature in terms of computational cost, accuracy in human identification, number of extracted features and number of samples for template creation. The proposed method is a suitable solution for human identification in contact-less scenarios based on hand biometrics, providing a feasible solution to devices with limited hardware requirements like mobile devices.

  12. Unconstrained and Contactless Hand Geometry Biometrics

    Directory of Open Access Journals (Sweden)

    Carmen Sánchez-Ávila

    2011-10-01

    Full Text Available This paper presents a hand biometric system for contact-less, platform-free scenarios, proposing innovative methods in feature extraction, template creation and template matching. The evaluation of the proposed method considers both the use of three contact-less publicly available hand databases, and the comparison of the performance to two competitive pattern recognition techniques existing in literature: namely Support Vector Machines (SVM and k-Nearest Neighbour (k-NN. Results highlight the fact that the proposed method outcomes existing approaches in literature in terms of computational cost, accuracy in human identification, number of extracted features and number of samples for template creation. The proposed method is a suitable solution for human identification in contact-less scenarios based on hand biometrics, providing a feasible solution to devices with limited hardware requirements like mobile devices.

  13. Development of a Three-Dimensional Hand Model Using Three-Dimensional Stereophotogrammetry: Assessment of Image Reproducibility.

    Directory of Open Access Journals (Sweden)

    Inge A Hoevenaren

    Full Text Available Using three-dimensional (3D stereophotogrammetry precise images and reconstructions of the human body can be produced. Over the last few years, this technique is mainly being developed in the field of maxillofacial reconstructive surgery, creating fusion images with computed tomography (CT data for precise planning and prediction of treatment outcome. Though, in hand surgery 3D stereophotogrammetry is not yet being used in clinical settings.A total of 34 three-dimensional hand photographs were analyzed to investigate the reproducibility. For every individual, 3D photographs were captured at two different time points (baseline T0 and one week later T1. Using two different registration methods, the reproducibility of the methods was analyzed. Furthermore, the differences between 3D photos of men and women were compared in a distance map as a first clinical pilot testing our registration method.The absolute mean registration error for the complete hand was 1.46 mm. This reduced to an error of 0.56 mm isolating the region to the palm of the hand. When comparing hands of both sexes, it was seen that the male hand was larger (broader base and longer fingers than the female hand.This study shows that 3D stereophotogrammetry can produce reproducible images of the hand without harmful side effects for the patient, so proving to be a reliable method for soft tissue analysis. Its potential use in everyday practice of hand surgery needs to be further explored.

  14. How do precision medicine and system biology response to human body's complex adaptability?

    Science.gov (United States)

    Yuan, Bing

    2016-12-01

    In the field of life sciences, although system biology and "precision medicine" introduce some complex scientifific methods and techniques, it is still based on the "analysis-reconstruction" of reductionist theory as a whole. Adaptability of complex system increase system behaviour uncertainty as well as the difficulties of precise identifification and control. It also put systems biology research into trouble. To grasp the behaviour and characteristics of organism fundamentally, systems biology has to abandon the "analysis-reconstruction" concept. In accordance with the guidelines of complexity science, systems biology should build organism model from holistic level, just like the Chinese medicine did in dealing with human body and disease. When we study the living body from the holistic level, we will fifind the adaptability of complex system is not the obstacle that increases the diffificulty of problem solving. It is the "exceptional", "right-hand man" that helping us to deal with the complexity of life more effectively.

  15. Evaluation of feedforward and feedback contributions to hand stiffness and variability in multijoint arm control.

    Science.gov (United States)

    He, Xin; Du, Yu-Fan; Lan, Ning

    2013-07-01

    The purpose of this study is to validate a neuromechanical model of the virtual arm (VA) by comparing emerging behaviors of the model to those of experimental observations. Hand stiffness of the VA model was obtained by either theoretical computation or simulated perturbations. Variability in hand position of the VA was generated by adding signal dependent noise (SDN) to the motoneuron pools of muscles. Reflex circuits of Ia, Ib and Renshaw cells were included to regulate the motoneuron pool outputs. Evaluation of hand stiffness and variability was conducted in simulations with and without afferent feedback under different patterns of muscle activations during postural maintenance. The simulated hand stiffness and variability ellipses captured the experimentally observed features in shape, magnitude and orientation. Steady state afferent feedback contributed significantly to the increase in hand stiffness by 35.75±16.99% in area, 18.37±7.80% and 16.15±7.15% in major and minor axes; and to the reduction of hand variability by 49.41±21.19% in area, 36.89±12.78% and 18.87±23.32% in major and minor axes. The VA model reproduced the neuromechanical behaviors that were consistent with experimental data, and it could be a useful tool for study of neural control of posture and movement, as well as for application to rehabilitation.

  16. SeleCon: Scalable IoT Device Selection and Control Using Hand Gestures.

    Science.gov (United States)

    Alanwar, Amr; Alzantot, Moustafa; Ho, Bo-Jhang; Martin, Paul; Srivastava, Mani

    2017-04-01

    Although different interaction modalities have been proposed in the field of human-computer interface (HCI), only a few of these techniques could reach the end users because of scalability and usability issues. Given the popularity and the growing number of IoT devices, selecting one out of many devices becomes a hurdle in a typical smarthome environment. Therefore, an easy-to-learn, scalable, and non-intrusive interaction modality has to be explored. In this paper, we propose a pointing approach to interact with devices, as pointing is arguably a natural way for device selection. We introduce SeleCon for device selection and control which uses an ultra-wideband (UWB) equipped smartwatch. To interact with a device in our system, people can point to the device to select it then draw a hand gesture in the air to specify a control action. To this end, SeleCon employs inertial sensors for pointing gesture detection and a UWB transceiver for identifying the selected device from ranging measurements. Furthermore, SeleCon supports an alphabet of gestures that can be used for controlling the selected devices. We performed our experiment in a 9 m -by-10 m lab space with eight deployed devices. The results demonstrate that SeleCon can achieve 84.5% accuracy for device selection and 97% accuracy for hand gesture recognition. We also show that SeleCon is power efficient to sustain daily use by turning off the UWB transceiver, when a user's wrist is stationary.

  17. LQG/LTR optimal attitude control of small flexible spacecraft using free-free boundary conditions

    Science.gov (United States)

    Fulton, Joseph M.

    Due to the volume and power limitations of a small satellite, careful consideration must be taken while designing an attitude control system for 3-axis stabilization. Placing redundancy in the system proves difficult and utilizing power hungry, high accuracy, active actuators is not a viable option. Thus, it is customary to find dependable, passive actuators used in conjunction with small scale active control components. This document describes the application of Elastic Memory Composite materials in the construction of a flexible spacecraft appendage, such as a gravity gradient boom. Assumed modes methods are used with Finite Element Modeling information to obtain the equations of motion for the system while assuming free-free boundary conditions. A discussion is provided to illustrate how cantilever mode shapes are not always the best assumption when modeling small flexible spacecraft. A key point of interest is first resonant modes may be needed in the system design plant in spite of these modes being greater than one order of magnitude in frequency when compared to the crossover frequency of the controller. LQG/LTR optimal control techniques are implemented to compute attitude control gains while controller robustness considerations determine appropriate reduced order controllers and which flexible modes to include in the design model. Key satellite designer concerns in the areas of computer processor sizing, material uncertainty impacts on the system model, and system performance variations resulting from appendage length modifications are addressed.

  18. Impact of the Spanish smoking control law on exposure to second-hand smoke and respiratory health in hospitality workers: a cohort study

    OpenAIRE

    Fernández Muñoz, Esteve; Fu Balboa, Marcela; Pascual, José A.; López, María José; Pérez-Ríos, Mónica; Schiaffino, Anna; Martínez Sánchez, Jose M.; Ariza, Carles; Saltó i Cerezuela, Esteve; Nebot, Manel

    2009-01-01

    BACKGROUND: A smoke-free law came into effect in Spain on 1st January 2006, affecting all enclosed workplaces except hospitality venues, whose proprietors can choose among totally a smoke-free policy, a partial restriction with designated smoking areas, or no restriction on smoking on the premises. We aimed to evaluate the impact of the law among hospitality workers by assessing second-hand smoke (SHS) exposure and the frequency of respiratory symptoms before and one year after the ban. METHO...

  19. The precision segmented reflectors: Moderate mission figure control subsystem

    Science.gov (United States)

    Sevaston, G.; Redding, D.; Lau, K.; Breckenridge, W.; Levine, B.; Nerheim, N.; Sirlin, S.; Kadogawa, H.

    1991-01-01

    A system concept for a space based segmented reflector telescope figure control subsystem is described. The concept employs a two phase architecture in which figure initialization and figure maintenance are independent functions. Figure initialization is accomplished by image sharpening using natural reference targets. Figure maintenance is performed by monitoring the relative positions and alignments of the telescope components using an optical truss. Actuation is achieved using precision positioners. Computer simulation results of figure initialization by pairwise segment coalignment/cophasing and simulated annealing are presented along with figure maintenance results using a wavefront error regulation algorithm. Both functions are shown to perform at acceptable levels for the class of submillimeter telescopes that are serving as the focus of this technology development effort. Component breadboard work as well as plans for a system testbed are discussed.

  20. Hands4U: the effectiveness of a multifaceted implementation strategy on behaviour related to the prevention of hand eczema-a randomised controlled trial among healthcare workers.

    Science.gov (United States)

    van der Meer, Esther W C; Boot, Cécile R L; Twisk, Jos W R; Coenraads, Pieter Jan; Jungbauer, Frank H W; van der Gulden, Joost W J; Anema, Johannes R

    2014-07-01

    To investigate the effects of a multifaceted implementation strategy on behaviour, behavioural determinants, knowledge and awareness of healthcare workers regarding the use of recommendations to prevent hand eczema. The Hands4U study is a randomised controlled trial. A total of 48 departments (n=1649 workers) were randomly allocated to the multifaceted implementation strategy or the control group (minimal implementation strategy). Within the departments designated to the multifaceted implementation strategy, participatory working groups were set up to enhance the implementation of the recommendations for hand eczema. In addition, working group members were trained to become role models, and an education session was given within the department. Outcome measures were awareness, knowledge, receiving information, behaviour and behavioural determinants. Data were collected at baseline, with a 3- and 6-month follow-up. Statistically significant effects were found after 6 months for awareness (OR 6.30; 95% CI 3.41 to 11.63), knowledge (B 0.74; 95% CI 0.54 to 0.95), receiving information (OR 9.81; 95% CI 5.60 to 17.18), washing hands (B -0.40; 95% -0.51 to -0.29), use of moisturiser (B 0.29; 95% CI 0.20 to 0.38), cotton under gloves (OR 3.94; 95% CI 2.04 to 7.60) and the overall compliance measure (B 0.14; 95% CI 0.02 to 0.26), as a result of the multifaceted implementation strategy. No effects were found for behavioural determinants. The multifaceted implementation strategy can be used in healthcare settings to enhance the implementation of recommendations for the prevention of hand eczema. NTR2812. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  1. Theory, simulation and experiments for precise deflection control of radiotherapy electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Figueroa, R.; Leiva, J.; Moncada, R.; Rojas, L.; Santibanez, M.; Valente, M.; Young, H. [Universidad de la Frontera, Centro de Fisica e Ingenieria en Medicina, Av. Francisco Salazar 1145, Casilla 54-D, Temuco (Chile); Velasquez, J. [Universidad de la Frontera, Departamento de Ciencias Fisicas, Av. Francisco Salazar 1145, Casilla 54-D, Temuco (Chile); Zelada, G. [Clinica Alemana de Santiago, Av. Vitacura 5951, 13132 Vitacura, Santiago (Chile); Astudillo, R., E-mail: rodolfo.figueroa@ufrontera.cl [Hospital Base de Valdivia, C. Simpson 850, XIV Region de los Rios, Valdivia (Chile)

    2017-10-15

    Conventional radiotherapy is mainly applied by linear accelerators. Although linear accelerators provide dual (electron/photon) radiation beam modalities, both of them are intrinsically produced by a megavoltage electron current. Modern radiotherapy treatment techniques are based on suitable devices inserted or attached to conventional linear accelerators. Thus, precise control of delivered beam becomes a main key issue. This work presents an integral description of electron beam deflection control as required for novel radiotherapy technique based on convergent photon beam production. Theoretical and Monte Carlo approaches were initially used for designing and optimizing devices components. Then, dedicated instrumentation was developed for experimental verification of electron beam deflection due to the designed magnets. Both Monte Carlo simulations and experimental results support the reliability of electrodynamics models used for predict megavoltage electron beam control. (Author)

  2. Theory, simulation and experiments for precise deflection control of radiotherapy electron beams

    International Nuclear Information System (INIS)

    Figueroa, R.; Leiva, J.; Moncada, R.; Rojas, L.; Santibanez, M.; Valente, M.; Young, H.; Velasquez, J.; Zelada, G.; Astudillo, R.

    2017-10-01

    Conventional radiotherapy is mainly applied by linear accelerators. Although linear accelerators provide dual (electron/photon) radiation beam modalities, both of them are intrinsically produced by a megavoltage electron current. Modern radiotherapy treatment techniques are based on suitable devices inserted or attached to conventional linear accelerators. Thus, precise control of delivered beam becomes a main key issue. This work presents an integral description of electron beam deflection control as required for novel radiotherapy technique based on convergent photon beam production. Theoretical and Monte Carlo approaches were initially used for designing and optimizing devices components. Then, dedicated instrumentation was developed for experimental verification of electron beam deflection due to the designed magnets. Both Monte Carlo simulations and experimental results support the reliability of electrodynamics models used for predict megavoltage electron beam control. (Author)

  3. Knowledge and opinion about smoke-free laws and second-hand smoke among hospitality venue managers in Gujarat and Andhra Pradesh, India.

    Science.gov (United States)

    Gupta, Vinay K; Arora, Monika; Sharma, Indrani; Nazar, Gaurang P; Modi, Bhavesh; Singh, Deepti; Millett, Christopher; Reddy, K Srinath

    2013-01-01

    India's Smoke-Free Law (SFL) was implemented in 2004 and reinforced on 2nd October 2008. This research attempts to understand the knowledge and opinion of hospitality venue (HV) managers about second-hand smoke (SHS) and SFL as well as self-reported compliance with SFL in two Indian states. A survey was conducted among 804 randomly sampled HVs from project STEPS (Strengthening of tobacco control efforts through innovative partnerships and strategies) in Gujarat and Andhra Pradesh, India. Four hundred and three HVs from two districts in Gujarat and 401 HVs from six districts in Andhra Pradesh were selected. The owner, manager or supervisor of each HV was interviewed using a pre-tested structured interview schedule. Association of opinion scales with respondents' background characteristics was assessed through the analysis of variance (ANOVA) method. Out of the 403 respondents in Gujarat and 401 in Andhra Pradesh, 56.1% and 84.3% had knowledge about SFL respectively. Compliance of HVs with SFL was 21.8% in Gujarat and 31.2% in Andhra Pradesh as reported by the managers. Knowledge about SHS was noted among 39.7% of respondents in Gujarat and 25.4% in Andhra Pradesh. Bivariate results indicated that more educated HV managers showed higher support for smoke-free public places (P < 0.001) and were more concerned about the health effects of SHS exposure (P = 0.002). Complete self-reported compliance with, and knowledge of SFL as well as SHS was not found in Gujarat and Andhra Pradesh. The education level of HV managers is an important determinant to ensure compliance with SFL in public places.

  4. Model-free adaptive control of advanced power plants

    Science.gov (United States)

    Cheng, George Shu-Xing; Mulkey, Steven L.; Wang, Qiang

    2015-08-18

    A novel 3-Input-3-Output (3.times.3) Model-Free Adaptive (MFA) controller with a set of artificial neural networks as part of the controller is introduced. A 3.times.3 MFA control system using the inventive 3.times.3 MFA controller is described to control key process variables including Power, Steam Throttle Pressure, and Steam Temperature of boiler-turbine-generator (BTG) units in conventional and advanced power plants. Those advanced power plants may comprise Once-Through Supercritical (OTSC) Boilers, Circulating Fluidized-Bed (CFB) Boilers, and Once-Through Supercritical Circulating Fluidized-Bed (OTSC CFB) Boilers.

  5. Biomechanical Reconstruction Using the Tacit Learning System: Intuitive Control of Prosthetic Hand Rotation.

    Science.gov (United States)

    Oyama, Shintaro; Shimoda, Shingo; Alnajjar, Fady S K; Iwatsuki, Katsuyuki; Hoshiyama, Minoru; Tanaka, Hirotaka; Hirata, Hitoshi

    2016-01-01

    Background: For mechanically reconstructing human biomechanical function, intuitive proportional control, and robustness to unexpected situations are required. Particularly, creating a functional hand prosthesis is a typical challenge in the reconstruction of lost biomechanical function. Nevertheless, currently available control algorithms are in the development phase. The most advanced algorithms for controlling multifunctional prosthesis are machine learning and pattern recognition of myoelectric signals. Despite the increase in computational speed, these methods cannot avoid the requirement of user consciousness and classified separation errors. "Tacit Learning System" is a simple but novel adaptive control strategy that can self-adapt its posture to environment changes. We introduced the strategy in the prosthesis rotation control to achieve compensatory reduction, as well as evaluated the system and its effects on the user. Methods: We conducted a non-randomized study involving eight prosthesis users to perform a bar relocation task with/without Tacit Learning System support. Hand piece and body motions were recorded continuously with goniometers, videos, and a motion-capture system. Findings: Reduction in the participants' upper extremity rotatory compensation motion was monitored during the relocation task in all participants. The estimated profile of total body energy consumption improved in five out of six participants. Interpretation: Our system rapidly accomplished nearly natural motion without unexpected errors. The Tacit Learning System not only adapts human motions but also enhances the human ability to adapt to the system quickly, while the system amplifies compensation generated by the residual limb. The concept can be extended to various situations for reconstructing lost functions that can be compensated.

  6. An automated hand hygiene compliance system is associated with improved monitoring of hand hygiene.

    Science.gov (United States)

    McCalla, Saungi; Reilly, Maggie; Thomas, Rowena; McSpedon-Rai, Dawn

    2017-05-01

    Consistent hand hygiene is key to reducing health care-associated infections (HAIs) and assessing compliance with hand hygiene protocols is vital for hospital infection control staff. A new automated hand hygiene compliance system (HHCS) was trialed as an alternative to human observers in an intensive care unit and an intensive care stepdown unit at a hospital facility in the northeastern United States. Using a retrospective cohort design, researchers investigated whether implementation of the HHCS resulted in improved hand hygiene compliance and a reduction in common HAI rates. Pearson χ 2 tests were used to assess changes in compliance, and incidence rate ratios were used to test for significant differences in infection rates. During the study period, the HHCS collected many more hand hygiene events compared with human observers (632,404 vs 480) and ensured that the hospital met its compliance goals (95%+). Although decreases in multidrug-resistant organisms, central line-associated bloodstream infections, and catheter-associated urinary tract infection rates were observed, they represented nonsignificant differences. Human hand hygiene observers may not report accurate measures of compliance. The HHCS is a promising new tool for fine-grained assessment of hand hygiene compliance. Further study is needed to examine the association between the HHCS and HAI rate reduction. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  7. Hand hygiene promotion and the participation of infection control link nurses: an effective innovation to overcome campaign fatigue.

    Science.gov (United States)

    Seto, Wing Hong; Yuen, Shanny W S; Cheung, Christina W Y; Ching, Patricia T Y; Cowling, Benjamin J; Pittet, Didier

    2013-12-01

    Campaign fatigue was evident in a large hospital in Hong Kong when hand hygiene compliance remained just above 50% after 4 years of aggressive and varied promotional activities. A new innovative strategy was developed that directly involved the infection control link nurses both in formulating the strategy and in implementing the various proposed programs. The new strategy was successful in increasing hand hygiene compliance to 83%. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  8. One-Handed Thumb Use on Smart Phones by Semi-literate and Illiterate Users in India

    Science.gov (United States)

    Katre, Dinesh

    There is a tremendous potential for developing mobile-based productivity tools and occupation specific applications for the semi-literate and illiterate users in India. One-handed thumb use on the touchscreen of smart phone or touch phone is considered as an effective alternative than the use of stylus or index finger, to free the other hand for supporting the occupational activity. In this context, usability research and experimental tests are conducted to understand the role of fine motor control, usability of thumb as the interaction apparatus and the ergonomic needs of users. The paper also touches upon cultural, racial and anthropometric aspects, which need due consideration while designing the mobile interface. Design recommendations are evolved to enhance the effectiveness of one-handed thumb use on smart phone, especially for the benefit of semi-literate and illiterate users.

  9. Deep learning with convolutional neural networks: a resource for the control of robotic prosthetic hands via electromyography

    Directory of Open Access Journals (Sweden)

    Manfredo Atzori

    2016-09-01

    Full Text Available Motivation: Natural control methods based on surface electromyography and pattern recognition are promising for hand prosthetics. However, the control robustness offered by scientific research is still not sufficient for many real life applications and commercial prostheses are in the best case capable to offer natural control for only a few movements. Objective: In recent years deep learning revolutionized several fields of machine learning, including computer vision and speech recognition. Our objective is to test its capabilities for the natural control of robotic hands via surface electromyography by providing a baseline on a large number of intact and amputated subjects. Methods: We tested convolutional networks for the classification of an average of 50 hand movements in 67 intact subjects and 11 hand amputated subjects. The simple architecture of the neural network allowed to make several tests in order to evaluate the effect of pre-processing, layer architecture, data augmentation and optimization. The classification results are compared with a set of classical classification methods applied on the same datasets.Results: The classification accuracy obtained with convolutional neural networks using the proposed architecture is higher than the average results obtained with the classical classification methods but lower than the results obtained with the best reference methods in our tests. Significance: The results show that convolutional neural networks with a very simple architecture can produce accuracy comparable to the average classical classification methods. They show that several factors (including pre-processing, the architecture of the net and the optimization parameters can be fundamental for the analysis of surface electromyography data. Finally, the results suggest that deeper and more complex networks may increase dexterous control robustness, thus contributing to bridge the gap between the market and scientific research

  10. Superior Intraparietal Sulcus Controls the Variability of Visual Working Memory Precision.

    Science.gov (United States)

    Galeano Weber, Elena M; Peters, Benjamin; Hahn, Tim; Bledowski, Christoph; Fiebach, Christian J

    2016-05-18

    Limitations of working memory (WM) capacity depend strongly on the cognitive resources that are available for maintaining WM contents in an activated state. Increasing the number of items to be maintained in WM was shown to reduce the precision of WM and to increase the variability of WM precision over time. Although WM precision was recently associated with neural codes particularly in early sensory cortex, we have so far no understanding of the neural bases underlying the variability of WM precision, and how WM precision is preserved under high load. To fill this gap, we combined human fMRI with computational modeling of behavioral performance in a delayed color-estimation WM task. Behavioral results replicate a reduction of WM precision and an increase of precision variability under high loads (5 > 3 > 1 colors). Load-dependent BOLD signals in primary visual cortex (V1) and superior intraparietal sulcus (IPS), measured during the WM task at 2-4 s after sample onset, were modulated by individual differences in load-related changes in the variability of WM precision. Although stronger load-related BOLD increase in superior IPS was related to lower increases in precision variability, thus stabilizing WM performance, the reverse was observed for V1. Finally, the detrimental effect of load on behavioral precision and precision variability was accompanied by a load-related decline in the accuracy of decoding the memory stimuli (colors) from left superior IPS. We suggest that the superior IPS may contribute to stabilizing visual WM performance by reducing the variability of memory precision in the face of higher load. This study investigates the neural bases of capacity limitations in visual working memory by combining fMRI with cognitive modeling of behavioral performance, in human participants. It provides evidence that the superior intraparietal sulcus (IPS) is a critical brain region that influences the variability of visual working memory precision between and

  11. Trajectory Control of Scale-Free Dynamical Networks with Exogenous Disturbances

    International Nuclear Information System (INIS)

    Yang Hongyong; Zhang Shun; Zong Guangdeng

    2011-01-01

    In this paper, the trajectory control of multi-agent dynamical systems with exogenous disturbances is studied. Suppose multiple agents composing of a scale-free network topology, the performance of rejecting disturbances for the low degree node and high degree node is analyzed. Firstly, the consensus of multi-agent systems without disturbances is studied by designing a pinning control strategy on a part of agents, where this pinning control can bring multiple agents' states to an expected consensus track. Then, the influence of the disturbances is considered by developing disturbance observers, and disturbance observers based control (DOBC) are developed for disturbances generated by an exogenous system to estimate the disturbances. Asymptotical consensus of the multi-agent systems with disturbances under the composite controller can be achieved for scale-free network topology. Finally, by analyzing examples of multi-agent systems with scale-free network topology and exogenous disturbances, the verities of the results are proved. Under the DOBC with the designed parameters, the trajectory convergence of multi-agent systems is researched by pinning two class of the nodes. We have found that it has more stronger robustness to exogenous disturbances for the high degree node pinned than that of the low degree node pinned. (interdisciplinary physics and related areas of science and technology)

  12. Application of Calibration Curve, Accuracy and Precision Chart as Internal Quality Control at COD Testing in Wastewater

    Directory of Open Access Journals (Sweden)

    Uray Lusiana

    2012-06-01

    Full Text Available Quality assurance is one of the technical requirements that include in the quality management system based on SNI ISO/IEC 17025 : 2008. Quality assurance is all the process that planned and systematic activity that applied in analysis, so can give the confidence to the customer or data user. Quality assurance that is applied for COD testing in wastewater are calibration curve, accuracy and precision control chart. The purpose of calibration curve, accuracy and precision control chart applied was to control the data of COD testing so that guaranty the validity to report and to keep the consistence of testing result as statistic all the time. Calibration curve of COD testing have a coefficient correlation 0,99987. Accuracy control chart have limited line BTA = 104,95%, BPA = 102,97%, BIA = 100,98%, BTB = 93,03%, BPB = 95,02% and BIB = 97,0%. Accuracy data can be accepted if that data present between line of BPA and BPB (± 2 SD, data is warned if that data present between line BTA-BPA or BTB-BPB (± 2 SD and ± 3 SD, and data is outlier if that data present out of line BTA and BTB (± 3 SD. The precision data can accepted if that the RPD value is not more than 10 % of COD testing result.

  13. Noncontrast magnetic resonance angiography of the hand: improved arterial conspicuity by multidirectional flow-sensitive dephasing magnetization preparation in 3D balanced steady-state free precession imaging.

    Science.gov (United States)

    Fan, Zhaoyang; Hodnett, Philip A; Davarpanah, Amir H; Scanlon, Timothy G; Sheehan, John J; Varga, John; Carr, James C; Li, Debiao

    2011-08-01

    : To develop a flow-sensitive dephasing (FSD) preparative scheme to facilitate multidirectional flow-signal suppression in 3-dimensional balanced steady-state free precession imaging and to validate the feasibility of the refined sequence for noncontrast magnetic resonance angiography (NC-MRA) of the hand. : A new FSD preparative scheme was developed that combines 2 conventional FSD modules. Studies using a flow phantom (gadolinium-doped water 15 cm/s) and the hands of 11 healthy volunteers (6 males and 5 females) were performed to compare the proposed FSD scheme with its conventional counterpart with respect to the signal suppression of multidirectional flow. In 9 of the 11 healthy subjects and 2 patients with suspected vasculitis and documented Raynaud phenomenon, respectively, 3-dimensional balanced steady-state free precession imaging coupled with the new FSD scheme was compared with spatial-resolution-matched (0.94 × 0.94 × 0.94 mm) contrast-enhanced magnetic resonance angiography (0.15 mmol/kg gadopentetate dimeglumine) in terms of overall image quality, venous contamination, motion degradation, and arterial conspicuity. : The proposed FSD scheme was able to suppress 2-dimensional flow signal in the flow phantom and hands and yielded significantly higher arterial conspicuity scores than the conventional scheme did on NC-MRA at the regions of common digitals and proper digitals. Compared with contrast-enhanced magnetic resonance angiography, the refined NC-MRA technique yielded comparable overall image quality and motion degradation, significantly less venous contamination, and significantly higher arterial conspicuity score at digital arteries. : The FSD-based NC-MRA technique is improved in the depiction of multidirectional flow by applying a 2-module FSD preparation, which enhances its potential to serve as an alternative magnetic resonance angiography technique for the assessment of hand vascular abnormalities.

  14. [Value of the space perception test for evaluation of the aptitude for precision work in geodesy].

    Science.gov (United States)

    Remlein-Mozolewska, G

    1982-01-01

    The visual spatial localization ability of geodesy and cartography - employers and of the pupils trained for the mentioned profession has been examined. The examination has been based on work duration and the time of its performance. A correlation between the localization ability and the precision of the hand - movements required in everyday work has been proven. The better the movement precision, the more efficient the visual spatial localization. The length of work has not been significant. The test concerned appeared to be highly useful in geodesy for qualifying workers for the posts requiring good hands efficiency.

  15. Right-handed charged currents in the era of the Large Hadron Collider

    Energy Technology Data Exchange (ETDEWEB)

    Alioli, S. [CERN Theory Division,CH-1211, Geneva 23 (Switzerland); Cirigliano, V. [Theoretical Division, Los Alamos National Laboratory,Los Alamos, NM 87545 (United States); Dekens, W. [Theoretical Division, Los Alamos National Laboratory,Los Alamos, NM 87545 (United States); New Mexico Consortium, Los Alamos Research Park,Los Alamos, NM 87544 (United States); Vries, J. de [Nikhef, Theory Group,Science Park 105, 1098 XG, Amsterdam (Netherlands); Mereghetti, E. [Theoretical Division, Los Alamos National Laboratory,Los Alamos, NM 87545 (United States)

    2017-05-16

    We discuss the phenomenology of right-handed charged currents in the framework of the Standard Model Effective Field Theory, in which they arise due to a single gauge-invariant dimension-six operator. We study the manifestations of the nine complex couplings of the W to right-handed quarks in collider physics, flavor physics, and low-energy precision measurements. We first obtain constraints on the couplings under the assumption that the right-handed operator is the dominant correction to the Standard Model at observable energies. We subsequently study the impact of degeneracies with other Beyond-the-Standard-Model effective interactions and identify observables, both at colliders and low-energy experiments, that would uniquely point to right-handed charged currents.

  16. Double nerve intraneural interface implant on a human amputee for robotic hand control.

    Science.gov (United States)

    Rossini, Paolo M; Micera, Silvestro; Benvenuto, Antonella; Carpaneto, Jacopo; Cavallo, Giuseppe; Citi, Luca; Cipriani, Christian; Denaro, Luca; Denaro, Vincenzo; Di Pino, Giovanni; Ferreri, Florinda; Guglielmelli, Eugenio; Hoffmann, Klaus-Peter; Raspopovic, Stanisa; Rigosa, Jacopo; Rossini, Luca; Tombini, Mario; Dario, Paolo

    2010-05-01

    The principle underlying this project is that, despite nervous reorganization following upper limb amputation, original pathways and CNS relays partially maintain their function and can be exploited for interfacing prostheses. Aim of this study is to evaluate a novel peripheral intraneural multielectrode for multi-movement prosthesis control and for sensory feed-back, while assessing cortical reorganization following the re-acquired stream of data. Four intrafascicular longitudinal flexible multielectrodes (tf-LIFE4) were implanted in the median and ulnar nerves of an amputee; they reliably recorded output signals for 4 weeks. Artificial intelligence classifiers were used off-line to analyse LIFE signals recorded during three distinct hand movements under voluntary order. Real-time control of motor output was achieved for the three actions. When applied off-line artificial intelligence reached >85% real-time correct classification of trials. Moreover, different types of current stimulation were determined to allow reproducible and localized hand/fingers sensations. Cortical organization was observed via TMS in parallel with partial resolution of symptoms due to the phantom-limb syndrome (PLS). tf-LIFE4s recorded output signals in human nerves for 4 weeks, though the efficacy of sensory stimulation decayed after 10 days. Recording from a number of fibres permitted a high percentage of distinct actions to be classified correctly. Reversal of plastic changes and alleviation of PLS represent corollary findings of potential therapeutic benefit. This study represents a breakthrough in robotic hand use in amputees. Copyright 2010 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  17. Free-flying dynamics and control of an astronaut assistant robot based on fuzzy sliding mode algorithm

    Science.gov (United States)

    Gao, Qing; Liu, Jinguo; Tian, Tongtong; Li, Yangmin

    2017-09-01

    Space robots can perform some tasks in harsh environment as assistants of astronauts or substitutions of astronauts. Taking the limited working time and the arduous task of the astronauts in the space station into account, an astronaut assistant robot (AAR-2) applied in the space station is proposed and designed in this paper. The AAR-2 is achieved with some improvements on the basis of AAR-1 which was designed before. It can exploit its position and attitude sensors and control system to free flight or hover in the space cabin. And it also has a definite environmental awareness and artificial intelligence to complete some specified tasks under the control of astronauts or autonomously. In this paper, it mainly analyzes and controls the 6-DOF motion of the AAR-2. Firstly, the system configuration of AAR-2 is specifically described, and the movement principles are analyzed. Secondly, according to the physical model of the AAR-2, the Newton - Euler equation is applied in the preparation of space dynamics model of 6-DOF motion. Then, according to the mathematical model's characteristics which are nonlinear and strong coupling, a dual closed loop position and attitude controller based on fuzzy sliding mode control is proposed and designed. Finally, simulation experiments are appropriate to provide for AAR-2 control system by using Matlab/Simulink. From the simulation results it can be observed that the designed fuzzy sliding mode controller can control the 6-DOF motion of AAR-2 quickly and precisely.

  18. Post-stroke Rehabilitation Training with a Motor-Imagery-Based Brain-Computer Interface (BCI)-Controlled Hand Exoskeleton: A Randomized Controlled Multicenter Trial.

    Science.gov (United States)

    Frolov, Alexander A; Mokienko, Olesya; Lyukmanov, Roman; Biryukova, Elena; Kotov, Sergey; Turbina, Lydia; Nadareyshvily, Georgy; Bushkova, Yulia

    2017-01-01

    Repeated use of brain-computer interfaces (BCIs) providing contingent sensory feedback of brain activity was recently proposed as a rehabilitation approach to restore motor function after stroke or spinal cord lesions. However, there are only a few clinical studies that investigate feasibility and effectiveness of such an approach. Here we report on a placebo-controlled, multicenter clinical trial that investigated whether stroke survivors with severe upper limb (UL) paralysis benefit from 10 BCI training sessions each lasting up to 40 min. A total of 74 patients participated: median time since stroke is 8 months, 25 and 75% quartiles [3.0; 13.0]; median severity of UL paralysis is 4.5 points [0.0; 30.0] as measured by the Action Research Arm Test, ARAT, and 19.5 points [11.0; 40.0] as measured by the Fugl-Meyer Motor Assessment, FMMA. Patients in the BCI group ( n = 55) performed motor imagery of opening their affected hand. Motor imagery-related brain electroencephalographic activity was translated into contingent hand exoskeleton-driven opening movements of the affected hand. In a control group ( n = 19), hand exoskeleton-driven opening movements of the affected hand were independent of brain electroencephalographic activity. Evaluation of the UL clinical assessments indicated that both groups improved, but only the BCI group showed an improvement in the ARAT's grasp score from 0 [0.0; 14.0] to 3.0 [0.0; 15.0] points ( p exoskeleton-assisted physical therapy can improve post-stroke rehabilitation outcomes. Both maximum and mean values of the percentage of successfully decoded imagery-related EEG activity, were higher than chance level. A correlation between the classification accuracy and the improvement in the upper extremity function was found. An improvement of motor function was found for patients with different duration, severity and location of the stroke.

  19. Technology: cancer treatment: breath control set radiotherapy free. Two new methods allow to aim the tumors with precision without suffering of respiratory move

    International Nuclear Information System (INIS)

    Blanc, S.

    2004-01-01

    The challenge of radiotherapy consists in improving the ratio between the destruction of tumor cells and the preservation of sane cells. The efficiency of the treatment depends on the precision of radiations impact on the tumor but this one is difficult to get because the patient respiration makes the target mobile. It is now possible to get this precision. It is a question to block the patient respiration or to register the movements and then establish the shooting window of radiations in function of the tumor optimum exposure. (N.C.)

  20. Subtractive fabrication of ferroelectric thin films with precisely controlled thickness

    Science.gov (United States)

    Ievlev, Anton V.; Chyasnavichyus, Marius; Leonard, Donovan N.; Agar, Joshua C.; Velarde, Gabriel A.; Martin, Lane W.; Kalinin, Sergei V.; Maksymovych, Petro; Ovchinnikova, Olga S.

    2018-04-01

    The ability to control thin-film growth has led to advances in our understanding of fundamental physics as well as to the emergence of novel technologies. However, common thin-film growth techniques introduce a number of limitations related to the concentration of defects on film interfaces and surfaces that limit the scope of systems that can be produced and studied experimentally. Here, we developed an ion-beam based subtractive fabrication process that enables creation and modification of thin films with pre-defined thicknesses. To accomplish this we transformed a multimodal imaging platform that combines time-of-flight secondary ion mass spectrometry with atomic force microscopy to a unique fabrication tool that allows for precise sputtering of the nanometer-thin layers of material. To demonstrate fabrication of thin-films with in situ feedback and control on film thickness and functionality we systematically studied thickness dependence of ferroelectric switching of lead-zirconate-titanate, within a single epitaxial film. Our results demonstrate that through a subtractive film fabrication process we can control the piezoelectric response as a function of film thickness as well as improve on the overall piezoelectric response versus an untreated film.

  1. Finger pressure adjustments to various object configurations during precision grip in humans and monkeys.

    Science.gov (United States)

    Viaro, Riccardo; Tia, Banty; Coudé, Gino; Canto, Rosario; Oliynyk, Andriy; Salmas, Paola; Masia, Lorenzo; Sandini, Giulio; Fadiga, Luciano

    2017-06-01

    In this study, we recorded the pressure exerted onto an object by the index finger and the thumb of the preferred hand of 18 human subjects and either hand of two macaque monkeys during a precision grasping task. The to-be-grasped object was a custom-made device composed by two plates which could be variably oriented by a motorized system while keeping constant the size and thus grip dimension. The to-be-grasped plates were covered by an array of capacitive sensors to measure specific features of finger adaptation, namely pressure intensity and centroid location and displacement. Kinematic measurements demonstrated that for human subjects and for monkeys, different plate configurations did not affect wrist velocity and grip aperture during the reaching phase. Consistently, at the instant of fingers-plates contact, pressure centroids were clustered around the same point for all handle configurations. However, small pressure centroid displacements were specifically adopted for each configuration, indicating that both humans and monkeys can display finger adaptation during precision grip. Moreover, humans applied stronger thumb pressure intensity, performed less centroid displacement and required reduced adjustment time, as compared to monkeys. These pressure patterns remain similar when different load forces were required to pull the handle, as ascertained by additional measurements in humans. The present findings indicate that, although humans and monkeys share common features in motor control of grasping, they differ in the adjustment of fingertip pressure, probably because of skill and/or morphology divergences. Such a precision grip device may form the groundwork for future studies on prehension mechanisms. © 2017 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  2. Performing Allen's test in immobile hand: The Esmarch bandage method

    Directory of Open Access Journals (Sweden)

    Nebil Yesiloglu

    2015-12-01

    Full Text Available In this study, an alternative method of assessing hand vascular flow using a modification of Allen's test is presented. This technique may be helpful for patients who have immobile hands due to severe trauma, patients scheduled for free tissue transfer reconstruction, patients under general anesthesia in intensive care units that require serial arterial blood gas analyses, and emergency coronary by-pass candidates who decided to receive radial arterial grafts. [Hand Microsurg 2015; 4(3.000: 83-85

  3. Use of hands-free technique among operating room nurses in the Republic of Korea.

    Science.gov (United States)

    Jeong, Ihn Sook; Park, Sunmi

    2009-03-01

    The recently introduced concept of hands-free technique (HFT) currently has no recommendations or formal educational program for use in the Republic of Korea. This study evaluated the level of HFT use and investigated factors related to HFT use among Korean operating room nurses. Data were obtained through a self-administered questionnaire from 158 operating room nurses in 7 general hospitals in Busan, Republic of Korea, in April and May 2006. The questionnaire elicited information on demographics, exposure to education on HFT, attitude toward the need for HFT, concerns about exposure to bloodborne pathogens, and experience with HTF use. Multilevel multiple logistic regression analysis with generalized estimating equations was used, and adjusted odds ratios (ORs) and their 95% confidence intervals (CIs) were calculated. We found that 56% of the participants had used HFT, and 50% had received education on HFT. The use of HFT had a significant association with both education on HFT (OR = 12.02; 95% CI = 7.50 to 19.25) and attitude toward the need for HFT (OR = 4.22; 95% CI = 2.43 to 7.35). Increasing education about HFT could be the most important approach to increasing the use of HFT among Korean operating room nurses. Thus, routine teaching about HFT should be provided to these nurses.

  4. Staphylococcus aureus and hand eczema severity

    DEFF Research Database (Denmark)

    Haslund, P; Bangsgaard, N; Jarløv, J O

    2009-01-01

    BACKGROUND: The role of bacterial infections in hand eczema (HE) remains to be assessed. OBJECTIVES: To determine the prevalence of Staphylococcus aureus in patients with HE compared with controls, and to relate presence of S. aureus, subtypes and toxin production to severity of HE. METHODS......: Bacterial swabs were taken at three different visits from the hand and nose in 50 patients with HE and 50 controls. Staphylococcus aureus was subtyped by spa typing and assigned to clonal complexes (CCs), and isolates were tested for exotoxin-producing S. aureus strains. The Hand Eczema Severity Index...... and in the nose in all cases, and between visits in 90% of cases. Ten different CC types were identified, no association with severity was found, and toxin-producing strains were not found more frequently in patients with HE than in controls. CONCLUSIONS: Staphylococcus aureus was present on hands in almost half...

  5. Flight control and landing precision in the nocturnal bee Megalopta is robust to large changes in light intensity

    Directory of Open Access Journals (Sweden)

    Emily eBaird

    2015-10-01

    Full Text Available Like its diurnal relatives, Megalopta genalis use visual information to control flight. Unlike their diurnal relatives, however, they do this at extremely low light intensities. Although Megalopta has developed optical specialisations to increase visual sensitivity, theoretical studies suggest that this enhanced sensitivity does not enable them to capture enough light to use visual information to reliably control flight in the rainforest at night. It has been proposed that Megalopta gain extra sensitivity by summing visual information over time. While enhancing the reliability of vision, this strategy would decrease the accuracy with which they can detect image motion - a crucial cue for flight control. Here, we test this temporal summation hypothesis by investigating how Megalopta’s flight control and landing precision is affected by light intensity and compare our findings with the results of similar experiments performed on the diurnal bumblebee Bombus terrestris, to explore the extent to which Megalopta’s adaptations to dim light affect their precision. We find that, unlike Bombus, light intensity does not affect flight and landing precision in Megalopta. Overall, we find little evidence that Megalopta uses a temporal summation strategy in dim light, while we find strong support for the use of this strategy in Bombus.

  6. SeleCon: Scalable IoT Device Selection and Control Using Hand Gestures

    Science.gov (United States)

    Alanwar, Amr; Alzantot, Moustafa; Ho, Bo-Jhang; Martin, Paul; Srivastava, Mani

    2018-01-01

    Although different interaction modalities have been proposed in the field of human-computer interface (HCI), only a few of these techniques could reach the end users because of scalability and usability issues. Given the popularity and the growing number of IoT devices, selecting one out of many devices becomes a hurdle in a typical smarthome environment. Therefore, an easy-to-learn, scalable, and non-intrusive interaction modality has to be explored. In this paper, we propose a pointing approach to interact with devices, as pointing is arguably a natural way for device selection. We introduce SeleCon for device selection and control which uses an ultra-wideband (UWB) equipped smartwatch. To interact with a device in our system, people can point to the device to select it then draw a hand gesture in the air to specify a control action. To this end, SeleCon employs inertial sensors for pointing gesture detection and a UWB transceiver for identifying the selected device from ranging measurements. Furthermore, SeleCon supports an alphabet of gestures that can be used for controlling the selected devices. We performed our experiment in a 9m-by-10m lab space with eight deployed devices. The results demonstrate that SeleCon can achieve 84.5% accuracy for device selection and 97% accuracy for hand gesture recognition. We also show that SeleCon is power efficient to sustain daily use by turning off the UWB transceiver, when a user’s wrist is stationary. PMID:29683151

  7. Chattering-free fuzzy sliding-mode control strategy for uncertain chaotic systems

    International Nuclear Information System (INIS)

    Yau, H.-T.; Chen, C.-L.

    2006-01-01

    This paper proposes a chattering-free fuzzy sliding-mode control (FSMC) strategy for uncertain chaotic systems. A fuzzy logic control is used to replace the discontinuous sign function of the reaching law in traditional sliding-mode control (SMC), and hence a control input without chattering is obtained in the chaotic systems with uncertainties. Base on the Lyapunov stability theory, we address the design schemes of integration fuzzy sliding-mode control, where the reaching law is proposed by a set of linguistic rules and the control input is chattering free. The Genesio chaotic system is used to test the proposed control strategy and the simulation results show the FSMC not only can control the uncertain chaotic behaviors to a desired state without oscillator very fast, but also the switching function is smooth without chattering. This result implies that this strategy is feasible and effective for chaos control

  8. Vision based interface system for hands free control of an intelligent wheelchair

    Directory of Open Access Journals (Sweden)

    Kim Eun

    2009-08-01

    Full Text Available Abstract Background Due to the shift of the age structure in today's populations, the necessities for developing the devices or technologies to support them have been increasing. Traditionally, the wheelchair, including powered and manual ones, is the most popular and important rehabilitation/assistive device for the disabled and the elderly. However, it is still highly restricted especially for severely disabled. As a solution to this, the Intelligent Wheelchairs (IWs have received considerable attention as mobility aids. The purpose of this work is to develop the IW interface for providing more convenient and efficient interface to the people the disability in their limbs. Methods This paper proposes an intelligent wheelchair (IW control system for the people with various disabilities. To facilitate a wide variety of user abilities, the proposed system involves the use of face-inclination and mouth-shape information, where the direction of an IW is determined by the inclination of the user's face, while proceeding and stopping are determined by the shapes of the user's mouth. Our system is composed of electric powered wheelchair, data acquisition board, ultrasonic/infra-red sensors, a PC camera, and vision system. Then the vision system to analyze user's gestures is performed by three stages: detector, recognizer, and converter. In the detector, the facial region of the intended user is first obtained using Adaboost, thereafter the mouth region is detected based on edge information. The extracted features are sent to the recognizer, which recognizes the face inclination and mouth shape using statistical analysis and K-means clustering, respectively. These recognition results are then delivered to the converter to control the wheelchair. Result & conclusion The advantages of the proposed system include 1 accurate recognition of user's intention with minimal user motion and 2 robustness to a cluttered background and the time-varying illumination

  9. Changes in bacterial flora associated with skin damage on hands of health care personnel.

    Science.gov (United States)

    Larson, E L; Hughes, C A; Pyrek, J D; Sparks, S M; Cagatay, E U; Bartkus, J M

    1998-10-01

    In a prospective observational study of 40 nurses (20 with diagnosed hand irritation and 20 without), nurses with damaged hands did not have higher microbial counts (P = .63), but did have a greater number of colonizing species (means: 3.35 and 2.63, P = .03). Although numbers were small, nurses with damaged hands were significantly more likely to be colonized with Staphylococcus hominis (P = .03). Fifty-nine percent of S hominis isolates from nurses with damaged hands were resistant to methicillin compared with 27% of isolates from those with healthy skin (P = .14). Twenty percent of nurses with damaged hands were colonized with Staphylococcus aureus compared with none of the nurses with normal hands (P = .11). Nurses with damaged hands were also twice as likely to have gram-negative bacteria (P = .20), entercocci (P = .13), and Candida (P = .30) present on the hands. Antimicrobial resistance of the coagulase-negative staphylococcal flora (with the exception of S hominis) did not differ between the 2 groups, nor did a trend toward increasing resistance exist when compared with other studies during the past decade. Skin moisturizers and protectant products were used almost universally by nurses at work, primarily products brought from home. Efforts to improve hand condition are warranted because skin damage can change microbial flora. Such efforts should include assessment or monitoring of hand care practices, formal institutional policy adoption and control of use of skin protectant products or lotions, and prudent use of latex gloves or more widespread use of powder-free and nonlatex products.

  10. Intelligent control of robotic arm/hand systems for the NASA EVA retriever using neural networks

    Science.gov (United States)

    Mclauchlan, Robert A.

    1989-01-01

    Adaptive/general learning algorithms using varying neural network models are considered for the intelligent control of robotic arm plus dextrous hand/manipulator systems. Results are summarized and discussed for the use of the Barto/Sutton/Anderson neuronlike, unsupervised learning controller as applied to the stabilization of an inverted pendulum on a cart system. Recommendations are made for the application of the controller and a kinematic analysis for trajectory planning to simple object retrieval (chase/approach and capture/grasp) scenarios in two dimensions.

  11. Prefrontal cortex activation upon a demanding virtual hand-controlled task: a new frontier for neuroergonomics

    Directory of Open Access Journals (Sweden)

    Marika eCarrieri

    2016-02-01

    Full Text Available Functional near-infrared spectroscopy (fNIRS is a non-invasive vascular-based functional neuroimaging technology that can assess, simultaneously from multiple cortical areas, concentration changes in oxygenated-deoxygenated hemoglobin at the level of the cortical microcirculation blood vessels. fNIRS, with its high degree of ecological validity and its very limited requirement of physical constraints to subjects, could represent a valid tool for monitoring cortical responses in the research field of neuroergonomics. In virtual reality (VR real situations can be replicated with greater control than those obtainable in the real world. Therefore, VR is the ideal setting where studies about neuroergonomics applications can be performed. The aim of the present study was to investigate, by a 20-channel fNIRS system, the dorsolateral/ventrolateral prefrontal cortex (DLPFC/VLPFC in subjects while performing a demanding VR hand-controlled task (HCT. Considering the complexity of the HCT, its execution should require the attentional resources allocation and the integration of different executive functions. The HCT simulates the interaction with a real, remotely-driven, system operating in a critical environment. The hand movements were captured by a high spatial and temporal resolution 3D hand-sensing device, the LEAP motion controller, a gesture-based control interface that could be used in VR for tele-operated applications. Fifteen University students were asked to guide, with their right hand/forearm, a virtual ball (VB over a virtual route (VROU reproducing a 42-m narrow road including some critical points. The subjects tried to travel as long as possible without making VB fall. The distance traveled by the guided VB was 70.2±37.2 m. The less skilled subjects failed several times in guiding the VB over the VROU. Nevertheless, a bilateral VLPFC activation, in response to the HCT execution, was observed in all the subjects. No correlation was found

  12. Prefrontal Cortex Activation Upon a Demanding Virtual Hand-Controlled Task: A New Frontier for Neuroergonomics.

    Science.gov (United States)

    Carrieri, Marika; Petracca, Andrea; Lancia, Stefania; Basso Moro, Sara; Brigadoi, Sabrina; Spezialetti, Matteo; Ferrari, Marco; Placidi, Giuseppe; Quaresima, Valentina

    2016-01-01

    Functional near-infrared spectroscopy (fNIRS) is a non-invasive vascular-based functional neuroimaging technology that can assess, simultaneously from multiple cortical areas, concentration changes in oxygenated-deoxygenated hemoglobin at the level of the cortical microcirculation blood vessels. fNIRS, with its high degree of ecological validity and its very limited requirement of physical constraints to subjects, could represent a valid tool for monitoring cortical responses in the research field of neuroergonomics. In virtual reality (VR) real situations can be replicated with greater control than those obtainable in the real world. Therefore, VR is the ideal setting where studies about neuroergonomics applications can be performed. The aim of the present study was to investigate, by a 20-channel fNIRS system, the dorsolateral/ventrolateral prefrontal cortex (DLPFC/VLPFC) in subjects while performing a demanding VR hand-controlled task (HCT). Considering the complexity of the HCT, its execution should require the attentional resources allocation and the integration of different executive functions. The HCT simulates the interaction with a real, remotely-driven, system operating in a critical environment. The hand movements were captured by a high spatial and temporal resolution 3-dimensional (3D) hand-sensing device, the LEAP motion controller, a gesture-based control interface that could be used in VR for tele-operated applications. Fifteen University students were asked to guide, with their right hand/forearm, a virtual ball (VB) over a virtual route (VROU) reproducing a 42 m narrow road including some critical points. The subjects tried to travel as long as possible without making VB fall. The distance traveled by the guided VB was 70.2 ± 37.2 m. The less skilled subjects failed several times in guiding the VB over the VROU. Nevertheless, a bilateral VLPFC activation, in response to the HCT execution, was observed in all the subjects. No correlation was found

  13. An hp symplectic pseudospectral method for nonlinear optimal control

    Science.gov (United States)

    Peng, Haijun; Wang, Xinwei; Li, Mingwu; Chen, Biaosong

    2017-01-01

    An adaptive symplectic pseudospectral method based on the dual variational principle is proposed and is successfully applied to solving nonlinear optimal control problems in this paper. The proposed method satisfies the first order necessary conditions of continuous optimal control problems, also the symplectic property of the original continuous Hamiltonian system is preserved. The original optimal control problem is transferred into a set of nonlinear equations which can be solved easily by Newton-Raphson iterations, and the Jacobian matrix is found to be sparse and symmetric. The proposed method, on one hand, exhibits exponent convergence rates when the number of collocation points are increasing with the fixed number of sub-intervals; on the other hand, exhibits linear convergence rates when the number of sub-intervals is increasing with the fixed number of collocation points. Furthermore, combining with the hp method based on the residual error of dynamic constraints, the proposed method can achieve given precisions in a few iterations. Five examples highlight the high precision and high computational efficiency of the proposed method.

  14. Computational Calorimetry: High-Precision Calculation of Host–Guest Binding Thermodynamics

    Science.gov (United States)

    2015-01-01

    We present a strategy for carrying out high-precision calculations of binding free energy and binding enthalpy values from molecular dynamics simulations with explicit solvent. The approach is used to calculate the thermodynamic profiles for binding of nine small molecule guests to either the cucurbit[7]uril (CB7) or β-cyclodextrin (βCD) host. For these systems, calculations using commodity hardware can yield binding free energy and binding enthalpy values with a precision of ∼0.5 kcal/mol (95% CI) in a matter of days. Crucially, the self-consistency of the approach is established by calculating the binding enthalpy directly, via end point potential energy calculations, and indirectly, via the temperature dependence of the binding free energy, i.e., by the van’t Hoff equation. Excellent agreement between the direct and van’t Hoff methods is demonstrated for both host–guest systems and an ion-pair model system for which particularly well-converged results are attainable. Additionally, we find that hydrogen mass repartitioning allows marked acceleration of the calculations with no discernible cost in precision or accuracy. Finally, we provide guidance for accurately assessing numerical uncertainty of the results in settings where complex correlations in the time series can pose challenges to statistical analysis. The routine nature and high precision of these binding calculations opens the possibility of including measured binding thermodynamics as target data in force field optimization so that simulations may be used to reliably interpret experimental data and guide molecular design. PMID:26523125

  15. A High-Precision Control for a ZVT PWM Soft-Switching Inverter to Eliminate the Dead-Time Effect

    Directory of Open Access Journals (Sweden)

    Baoquan Kou

    2016-07-01

    Full Text Available Attributing to the advantages of high efficiency, low electromagnetic interference (EMI noise and closest to the pulse-width-modulation (PWM converter counterpart, zero-voltage-transition (ZVT PWM soft-switching inverters are very suitable for high-performance applications. However, the conventional control algorithms intended for high efficiency generally results in voltage distortion. Thus, this paper, for the first time, proposes a high-precision control method to eliminate the dead-time effect through controlling the auxiliary current in the auxiliary resonant snubber inverter (ARSI, which is a typical ZVT PWM inverter. The dead-time effect of ARSI is analyzed, which is distinguished from hard-switching inverters. The proposed high-precision control is introduced based on the investigation of dead-time effect. A prototype was developed to verify the effectiveness of the proposed control. The experimental results shows that the total harmonic distortion (THD of the output current of the ARSI can be reduced compared with that of the hard-switching inverter, because the blanking delay error is eliminated. The quality of the output current and voltage can be further improved by utilizing the proposed control method.

  16. An on-line BCI for control of hand grasp sequence and holding using adaptive probabilistic neural network.

    Science.gov (United States)

    Hazrati, Mehrnaz Kh; Erfanian, Abbas

    2008-01-01

    This paper presents a new EEG-based Brain-Computer Interface (BCI) for on-line controlling the sequence of hand grasping and holding in a virtual reality environment. The goal of this research is to develop an interaction technique that will allow the BCI to be effective in real-world scenarios for hand grasp control. Moreover, for consistency of man-machine interface, it is desirable the intended movement to be what the subject imagines. For this purpose, we developed an on-line BCI which was based on the classification of EEG associated with imagination of the movement of hand grasping and resting state. A classifier based on probabilistic neural network (PNN) was introduced for classifying the EEG. The PNN is a feedforward neural network that realizes the Bayes decision discriminant function by estimating probability density function using mixtures of Gaussian kernels. Two types of classification schemes were considered here for on-line hand control: adaptive and static. In contrast to static classification, the adaptive classifier was continuously updated on-line during recording. The experimental evaluation on six subjects on different days demonstrated that by using the static scheme, a classification accuracy as high as the rate obtained by the adaptive scheme can be achieved. At the best case, an average classification accuracy of 93.0% and 85.8% was obtained using adaptive and static scheme, respectively. The results obtained from more than 1500 trials on six subjects showed that interactive virtual reality environment can be used as an effective tool for subject training in BCI.

  17. Evaluation-Function-based Model-free Adaptive Fuzzy Control

    Directory of Open Access Journals (Sweden)

    Agus Naba

    2016-12-01

    Full Text Available Designs of adaptive fuzzy controllers (AFC are commonly based on the Lyapunov approach, which requires a known model of the controlled plant. They need to consider a Lyapunov function candidate as an evaluation function to be minimized. In this study these drawbacks were handled by designing a model-free adaptive fuzzy controller (MFAFC using an approximate evaluation function defined in terms of the current state, the next state, and the control action. MFAFC considers the approximate evaluation function as an evaluative control performance measure similar to the state-action value function in reinforcement learning. The simulation results of applying MFAFC to the inverted pendulum benchmark verified the proposed scheme’s efficacy.

  18. Design, dynamics and control of an Adaptive Singularity-Free Control Moment Gyroscope actuator for microspacecraft Attitude Determination and Control System

    Science.gov (United States)

    Viswanathan, Sasi Prabhakaran

    how they lead to CMG singularities, are described. General ideas on control of the angular momentum of the spacecraft using changes in the momentum variables of a finite number of ASCMGs, are provided. Control schemes for agile and precise attitude maneuvers using ASCMG cluster in the absence of external torques and when the total angular momentum of the spacecraft is zero, is presented for both constant speed and variable speed modes. A Geometric Variational Integrator (GVI) that preserves the geometry of the state space and the conserved norm of the total angular momentum is constructed for numerical simulation and microcontroller implementation of the control scheme. The GVI is obtained by discretizing the Lagrangian of the rnultibody systems, in which the rigid body attitude is globally represented on the Lie group of rigid body rotations. Hardware and software architecture of a novel spacecraft Attitude Determination and Control System (ADCS) based on commercial smartphones and a bare minimum hardware prototype of an ASCMG using low cost COTS components is also described. A lightweight, dynamics model-free Variational Attitude Estimator (VAE) suitable for smartphone implementation is employed for attitude determination and the attitude control is performed by ASCMG actuators. The VAE scheme presented here is implemented and validated onboard an Unmanned Aerial Vehicle (UAV) platform and the real time performance is analyzed. On-board sensing, data acquisition, data uplink/downlink, state estimation and real-time feedback control objectives can be performed using this novel spacecraft ADCS. The mechatronics realization of the attitude determination through variational attitude estimation scheme and control implementation using ASCMG actuators are presented here. Experimental results of the attitude estimation (filtering) scheme using smartphone sensors as an Inertial Measurement Unit (IMU) on the Hardware In the Loop (HIL) simulator testbed are given. These

  19. Modeling and controller design of a 6-DOF precision positioning system

    Science.gov (United States)

    Cai, Kunhai; Tian, Yanling; Liu, Xianping; Fatikow, Sergej; Wang, Fujun; Cui, Liangyu; Zhang, Dawei; Shirinzadeh, Bijan

    2018-05-01

    A key hurdle to meet the needs of micro/nano manipulation in some complex cases is the inadequate workspace and flexibility of the operation ends. This paper presents a 6-degree of freedom (DOF) serial-parallel precision positioning system, which consists of two compact type 3-DOF parallel mechanisms. Each parallel mechanism is driven by three piezoelectric actuators (PEAs), guided by three symmetric T-shape hinges and three elliptical flexible hinges, respectively. It can extend workspace and improve flexibility of the operation ends. The proposed system can be assembled easily, which will greatly reduce the assembly errors and improve the positioning accuracy. In addition, the kinematic and dynamic model of the 6-DOF system are established, respectively. Furthermore, in order to reduce the tracking error and improve the positioning accuracy, the Discrete-time Model Predictive Controller (DMPC) is applied as an effective control method. Meanwhile, the effectiveness of the DMCP control method is verified. Finally, the tracking experiment is performed to verify the tracking performances of the 6-DOF stage.

  20. Long-term in-vitro precision of direct digital X-ray radiogrammetry

    International Nuclear Information System (INIS)

    Dhainaut, Alvilde; Hoff, Mari; Kaelvesten, Johan; Lydersen, Stian; Forslind, Kristina; Haugeberg, Glenn

    2011-01-01

    Digital X-ray radiogrammetry (DXR) calculates peripheral bone mineral density (BMD) from hand radiographs. The short-term precision for direct DXR has been reported to be highly satisfactory. However, long-term precision for this method has not been examined. Thus, the aim of this study was to examine the long-term in-vitro precision for the new direct digital version of DXR. The in-vitro precision for direct DXR was tested with cadaver phantoms on four different X-ray systems at baseline, 3 months, 6 months, and in one machine also at 12 months. At each time point, 31 measurements were performed. The in-vitro longitudinal precision for the four radiographic systems ranged from 0.22 to 0.43% expressed as coefficient of variation (CV%). The smallest detectable difference (SDD) ranged from 0.0034 to 0.0054 g/cm 2 . The in vitro long-term precision for direct DXR was comparable to the previous reported short-term in-vitro precision for all tested X-ray systems. These data show that DXR is a stable method for detecting small changes in bone density during 6-12 months of follow-up. (orig.)

  1. Precision for Smallholder Farmers: A Small-Scale-Tailored Variable Rate Fertilizer Application Kit

    Directory of Open Access Journals (Sweden)

    Jelle Van Loon

    2018-03-01

    Full Text Available Precision agriculture technology at the hands of smallholder farmers in the developing world is often deemed far-fetched. Low-resource farmers, however, are the most susceptible to negative changes in the environment. Providing these farmers with the right tools to mitigate adversity and to gain greater control of the production process could unlock their potential and support rural communities to meet the increasing global food demand. In this study, a real-time variable rate fertilizer application system was developed and tested as an add-on kit to conventional farm machinery. In the context of low investment costs for smallholder farmers, high user-friendliness and easy installment were the main concerns for the system to be viable. The system used nitrogen (N-sensors to assess the plant nutrient status on the spot and subsequently adjust the amount of fertilizer deposited according to the plant’s needs. Test bench trials showed that the add-on kit performed well with basic operations, but more precision is required. Variability between N-sensors and metering systems, combined with power fluctuations, created inaccuracies in the resulting application rate. Nevertheless, this work is a stepping stone towards catalyzing the elaboration of more cutting-edge precision solutions to support small-scale farmers to become successful, high producing agro-entrepreneurs.

  2. Effects of Computer-Aided Manufacturing Technology on Precision of Clinical Metal-Free Restorations.

    Science.gov (United States)

    Lee, Ki-Hong; Yeo, In-Sung; Wu, Benjamin M; Yang, Jae-Ho; Han, Jung-Suk; Kim, Sung-Hun; Yi, Yang-Jin; Kwon, Taek-Ka

    2015-01-01

    The purpose of this study was to investigate the marginal fit of metal-free crowns made by three different computer-aided design/computer-aided manufacturing (CAD/CAM) systems. The maxillary left first premolar of a dentiform was prepared for all-ceramic crown restoration. Thirty all-ceramic premolar crowns were made, ten each manufactured by the Lava system, Cercon, and Cerec. Ten metal ceramic gold (MCG) crowns served as control. The marginal gap of each sample was measured under a stereoscopic microscope at 75x magnification after cementation. One-way ANOVA and the Duncan's post hoc test were used for data analysis at the significance level of 0.05. The mean (standard deviation) marginal gaps were 70.5 (34.4) μm for the MCG crowns, 87.2 (22.8) μm for Lava, 58.5 (17.6) μm for Cercon, and 72.3 (30.8) μm for Cerec. There were no significant differences in the marginal fit among the groups except that the Cercon crowns had significantly smaller marginal gaps than the Lava crowns (P < 0.001). Within the limitation of this study, all the metal-free restorations made by the digital CAD/CAM systems had clinically acceptable marginal accuracy.

  3. RPCs: the choreography of precise timing

    CERN Document Server

    Boyko, I; Dydak, F; Elagin, A; Gostkin, M; Koreshev, V; Nefedov, Y; Nikolaev, K; Wotschack, J; Zhemchugov, A

    2005-01-01

    We present a comprehensive overview of all steps to be taken in order to achieve precise timing of the HARP RPCs. After briefly recalling the salient features of the RPC mechanics and electronics, we discuss the results from the dedicated calibration scan in a -12 GeV/c beam which gave valuable first information on efficiency and uniformity of response, charge attenuation, the global time slewing correction, effective strip transit time, relative delays between strips of a pad, and intrinsic time resolution. The latter was determined to be ~140 ps which sets the scale for the control of systematic effects, so as not to deteriorate significantly the overall time-of-flight resolution of the RPCs. From physics data, primarily from `neutral' and `charged' hits in RPC overlap regions, further refinements are derived, in particular padring-specific modifications of the global time slewing correction, and manifestations of the `knock-on' and noise' effects. With a view to a bias-free determination of pad-specific t0...

  4. A hand-held robotic device for peripheral intravenous catheterization.

    Science.gov (United States)

    Cheng, Zhuoqi; Davies, Brian L; Caldwell, Darwin G; Barresi, Giacinto; Xu, Qinqi; Mattos, Leonardo S

    2017-12-01

    Intravenous catheterization is frequently required for numerous medical treatments. However, this process is characterized by a high failure rate, especially when performed on difficult patients such as newborns and infants. Very young patients have small veins, and that increases the chances of accidentally puncturing the catheterization needle directly through them. In this article, we present the design, development and experimental evaluation of a novel hand-held robotic device for improving the process of peripheral intravenous catheterization by facilitating the needle insertion procedure. To our knowledge, this design is the first hand-held robotic device for assisting in the catheterization insertion task. Compared to the other available technologies, it has several unique advantages such as being compact, low-cost and able to reliably detect venipuncture. The system is equipped with an electrical impedance sensor at the tip of the catheterization needle, which provides real-time measurements used to supervise and control the catheter insertion process. This allows the robotic system to precisely position the needle within the lumen of the target vein, leading to enhanced catheterization success rate. Experiments conducted to evaluate the device demonstrated that it is also effective to deskill the task. Naïve subjects achieved an average catheterization success rate of 88% on a 1.5 mm phantom vessel with the robotic device versus 12% with the traditional unassisted system. The results of this work prove the feasibility of a hand-held assistive robotic device for intravenous catheterization and show that such device has the potential to greatly improve the success rate of these difficult operations.

  5. Dead Zone Oscillator Control for Communication-Free Synchronization of Paralleled, Three-Phase, Current-Controlled Inverters

    Science.gov (United States)

    2016-05-11

    Current-Controlled Inverters by Midshipman 1/C Spencer C. Shabshab, USN UNITED STATES NAVAL ACADEMY...Three-Phase, Current-Controlled Inverters by Midshipman 1/C Spencer C. Shabshab United States Naval Academy Annapolis, Maryland...for Communication-Free Synchronization of Paralleled, 5a. CONTRACT NUMBER Three-Phase, Current-Controlled Inverters 5b. GRANT NUMBER 5c

  6. Designing sequence to control protein function in an EF-hand protein.

    Science.gov (United States)

    Bunick, Christopher G; Nelson, Melanie R; Mangahas, Sheryll; Hunter, Michael J; Sheehan, Jonathan H; Mizoue, Laura S; Bunick, Gerard J; Chazin, Walter J

    2004-05-19

    The extent of conformational change that calcium binding induces in EF-hand proteins is a key biochemical property specifying Ca(2+) sensor versus signal modulator function. To understand how differences in amino acid sequence lead to differences in the response to Ca(2+) binding, comparative analyses of sequence and structures, combined with model building, were used to develop hypotheses about which amino acid residues control Ca(2+)-induced conformational changes. These results were used to generate a first design of calbindomodulin (CBM-1), a calbindin D(9k) re-engineered with 15 mutations to respond to Ca(2+) binding with a conformational change similar to that of calmodulin. The gene for CBM-1 was synthesized, and the protein was expressed and purified. Remarkably, this protein did not exhibit any non-native-like molten globule properties despite the large number of mutations and the nonconservative nature of some of them. Ca(2+)-induced changes in CD intensity and in the binding of the hydrophobic probe, ANS, implied that CBM-1 does undergo Ca(2+) sensorlike conformational changes. The X-ray crystal structure of Ca(2+)-CBM-1 determined at 1.44 A resolution reveals the anticipated increase in hydrophobic surface area relative to the wild-type protein. A nascent calmodulin-like hydrophobic docking surface was also found, though it is occluded by the inter-EF-hand loop. The results from this first calbindomodulin design are discussed in terms of progress toward understanding the relationships between amino acid sequence, protein structure, and protein function for EF-hand CaBPs, as well as the additional mutations for the next CBM design.

  7. Effects of hyperthyroidism on hand grip strength and function.

    Science.gov (United States)

    Erkol İnal, Esra; Çarlı, Alparslan Bayram; Çanak, Sultan; Aksu, Oğuzhan; Köroğlu, Banu Kale; Savaş, Serpil

    2015-01-01

    Hyperthyroidism is a pathologic condition in which the body is exposed to excessive amounts of circulating thyroid hormones. Skeletal muscle is one of the major target organs of thyroid hormones. We evaluated hand grip strength and function in patients with overt hyperthyroidism. Fifty-one patients newly diagnosed with hyperthyroidism and 44 healthy controls participated in this study. Age, height, weight, and dominant hand of all participants were recorded. The diagnosis of hyperthyroidism was confirmed by clinical examination and laboratory tests. Hand grip strength was tested at the dominant hand with a Jamar hand dynamometer. The grooved pegboard test (PGT) was used to evaluate hand dexterity. The Duruöz Hand Index (DHI) was used to assess hand function. No significant differences were found in terms of clinical and demographic findings between the patients with hyperthyroidism and healthy controls (p > 0.05). Significant differences were found between the patients with hyperthyroidism and healthy controls regarding PGT and DHI scores (p Hyperthyroidism seemed to affect hand dexterity and function more than hand grip strength and seemed to be associated with reduced physical function more than muscle strength. This may also indicate that patients with hyperthyroidism should be evaluated by multidisplinary modalities.

  8. Viewing geometry determines the contribution of binocular vision to the online control of grasping.

    Science.gov (United States)

    Keefe, Bruce D; Watt, Simon J

    2017-12-01

    Binocular vision is often assumed to make a specific, critical contribution to online visual control of grasping by providing precise information about the separation between digits and object. This account overlooks the 'viewing geometry' typically encountered in grasping, however. Separation of hand and object is rarely aligned precisely with the line of sight (the visual depth dimension), and analysis of the raw signals suggests that, for most other viewing angles, binocular feedback is less precise than monocular feedback. Thus, online grasp control relying selectively on binocular feedback would not be robust to natural changes in viewing geometry. Alternatively, sensory integration theory suggests that different signals contribute according to their relative precision, in which case the role of binocular feedback should depend on viewing geometry, rather than being 'hard-wired'. We manipulated viewing geometry, and assessed the role of binocular feedback by measuring the effects on grasping of occluding one eye at movement onset. Loss of binocular feedback resulted in a significantly less extended final slow-movement phase when hand and object were separated primarily in the frontoparallel plane (where binocular information is relatively imprecise), compared to when they were separated primarily along the line of sight (where binocular information is relatively precise). Consistent with sensory integration theory, this suggests the role of binocular (and monocular) vision in online grasp control is not a fixed, 'architectural' property of the visuo-motor system, but arises instead from the interaction of viewer and situation, allowing robust online control across natural variations in viewing geometry.

  9. Comparison of working length control consistency between hand K-files and Mtwo NiTi rotary system.

    Science.gov (United States)

    Krajczár, Károly; Varga, Enikő; Marada, Gyula; Jeges, Sára; Tóth, Vilmos

    2016-04-01

    The purpose of this study was to investigate the consistency of working length control between hand instrumentation in comparison to engine driven Mtwo nickel-titanium rotary files. Forty extracted maxillary molars were selected and divided onto two parallel groups. The working lengths of the mesiobuccal root canals were estimated. The teeth were fixed in a phantom head. The root canal preparation was carried out group 1 (n=20) with hand K-files, (VDW, Munich, Germany) and group 2 (n=20) with Mtwo instruments (VDW, Munich, Germany). Vestibulo-oral and mesio-distal directional x-ray images were taken before the preparation with #10 K-file, inserted into the mesiobuccal root canal to the working length, and after preparation with #25, #30 and #40 files. Working lenght changes were detected with measurements between the radiological apex and the instrument tips. In the Mtwo group a difference in the working competency (protary files. Mtwo NiTi rotary file did therefore proved to be more accurate in comparison to the conventional hand instrumentation. Working length, Mtwo, nickel-titanium, hand preparation, engine driven preparation.

  10. Anthropomorphic Robot Hand And Teaching Glove

    Science.gov (United States)

    Engler, Charles D., Jr.

    1991-01-01

    Robotic forearm-and-hand assembly manipulates objects by performing wrist and hand motions with nearly human grasping ability and dexterity. Imitates hand motions of human operator who controls robot in real time by programming via exoskeletal "teaching glove". Telemanipulator systems based on this robotic-hand concept useful where humanlike dexterity required. Underwater, high-radiation, vacuum, hot, cold, toxic, or inhospitable environments potential application sites. Particularly suited to assisting astronauts on space station in safely executing unexpected tasks requiring greater dexterity than standard gripper.

  11. Precision Joining Center

    Science.gov (United States)

    Powell, J. W.; Westphal, D. A.

    1991-08-01

    A workshop to obtain input from industry on the establishment of the Precision Joining Center (PJC) was held on July 10-12, 1991. The PJC is a center for training Joining Technologists in advanced joining techniques and concepts in order to promote the competitiveness of U.S. industry. The center will be established as part of the DOE Defense Programs Technology Commercialization Initiative, and operated by EG&G Rocky Flats in cooperation with the American Welding Society and the Colorado School of Mines Center for Welding and Joining Research. The overall objectives of the workshop were to validate the need for a Joining Technologists to fill the gap between the welding operator and the welding engineer, and to assure that the PJC will train individuals to satisfy that need. The consensus of the workshop participants was that the Joining Technologist is a necessary position in industry, and is currently used, with some variation, by many companies. It was agreed that the PJC core curriculum, as presented, would produce a Joining Technologist of value to industries that use precision joining techniques. The advantage of the PJC would be to train the Joining Technologist much more quickly and more completely. The proposed emphasis of the PJC curriculum on equipment intensive and hands-on training was judged to be essential.

  12. Free-Piston Stirling Convertor Controller Development at NASA Glenn Research Center

    Science.gov (United States)

    Regan, Timothy

    2004-01-01

    The free-piston Stirling convertor end-to-end modeling effort at NASA Glenn Research Center (GRC) has produced a software-based test bed in which free-piston Stirling convertors can be simulated and evaluated. The simulation model includes all the components of the convertor - the Stirling cycle engine, linear alternator, controller, and load. This paper is concerned with controllers. It discusses three controllers that have been studied using this model. Case motion has been added to the model recently so that effects of differences between convertor components can be simulated and ameliorative control engineering techniques can be developed. One concern when applying a system comprised of interconnected mass-spring-damper components is to prevent operation in any but the intended mode. The design mode is the only desired mode of operation, but all other modes are considered in controller design.

  13. Evaluation of the effect of balneotherapy in patients with osteoarthritis of the hands: a randomized controlled single-blind follow-up study.

    Science.gov (United States)

    Horváth, Katalin; Kulisch, Ágota; Németh, András; Bender, Tamás

    2012-05-01

    To evaluate the effectiveness of thermal mineral water compared with magnetotherapy without balneotherapy as control, in the treatment of hand osteoarthritis. Randomized controlled single-blind follow-up study. Rheumatology specialist clinic of Gunaras Health Spa. Patients between 50 and 70 years of age with hand osteoarthritis, randomly assigned into three groups. The subjects in the first two groups bathed in thermal mineral water of two different temperatures (36°C and 38°C) for three weeks five times a week for 20 minutes a day and received magnetotherapy to their hands three times weekly. The third group received only magnetotherapy. Visual analogue scale scores, handgrip strength, pinchgrip strength, the number of swollen and tender joints of the hand, the duration of morning joint stiffness, Health Assessment Questionnaire, and Short Form-36 questionnaire. The study parameters were administered at baseline, immediately after treatment and after 13 weeks. The study included 63 patients. Statistically significant improvement was observed in several studied parameters after the treatment and during the follow-up study in the thermal water groups versus the control group. The 38°C thermal water treatment significantly improved the pinch strength of the right hand (0.6 (95% confidence interval (CI) 0.2 to 1.1) vs. 0.03 (95% CI -0.3 to 0.4), P magnetotherapy improved the pain and function as well as the quality of life in patients with hand osteoarthritis.

  14. High precision laser control of the ATLAS tile-calorimeter module mass production at JINR

    International Nuclear Information System (INIS)

    Batusov, V.; Budagov, Yu.; Flyagin, V.; Khubua, D.; Lomakin, Yu.; Lyablin, M.; Rusakovich, N.; Shabalin, D.; Topilin, N.; Nessi, M.

    2001-01-01

    We present a short description of our last few years experience in the quality control of the ATLAS hadron barrel tile-calorimeter module mass production at JINR. A Laser Measurement System (LMS) proposed and realized in Dubna guarantees a high-precision module assembly. The non-planarity of module size surfaces (1.9x5.6 m) controlled area is well within the required ±0.6 mm tolerance for each of JINR assembled modules. The module assembly technique achieved with the LMS system allows us to deliver to CERN one module every 2 weeks. This laser-based measurement system could be used in future for the control measurement of other large-scale units during the ATLAS assembly

  15. A control system for a free electron laser experiment

    International Nuclear Information System (INIS)

    Giove, D.

    1992-01-01

    The general layout of a control and data acquisition system for a Free Electron Laser experiment will be discussed. Some general considerations about the requirements and the architecture of the whole system will be developed. (author)

  16. 3 x 3 free-space optical router based on crossbar network and its control algorithm

    Science.gov (United States)

    Hou, Peipei; Sun, Jianfeng; Yu, Zhou; Lu, Wei; Wang, Lijuan; Liu, Liren

    2015-08-01

    A 3 × 3 free-space optical router, which comprises optical switches and polarizing beam splitter (PBS) and based on crossbar network, is proposed in this paper. A control algorithm for the 3 × 3 free-space optical router is also developed to achieve rapid control without rearrangement. In order to test the performance of the network based on 3 × 3 free-space optical router and that of the algorithm developed for the optical router, experiments are designed. The experiment results show that the interconnection network based on the 3 × 3 free-space optical router has low cross talk, fast connection speed. Under the control of the algorithm developed, a non-block and real free interconnection network is obtained based on the 3 × 3 free-space optical router we proposed.

  17. Hands-on Precision Agriculture Data Management Workshops for Producers and Industry Professionals: Development and Assessment

    Science.gov (United States)

    Luck, Joe D.; Fulton, John P.; Rees, Jennifer

    2015-01-01

    Three Precision Agriculture Data Management workshops regarding yield monitor data were conducted in 2014, reaching 62 participants. Post-workshop surveys (n = 58) indicated 73% of respondents experienced a moderate to significant increase in knowledge related to yield monitor data usage. Another 72% reported that they planned to utilize best…

  18. Robust approximation-free prescribed performance control for nonlinear systems and its application

    Science.gov (United States)

    Sun, Ruisheng; Na, Jing; Zhu, Bin

    2018-02-01

    This paper presents a robust prescribed performance control approach and its application to nonlinear tail-controlled missile systems with unknown dynamics and uncertainties. The idea of prescribed performance function (PPF) is incorporated into the control design, such that both the steady-state and transient control performance can be strictly guaranteed. Unlike conventional PPF-based control methods, we further tailor a recently proposed systematic control design procedure (i.e. approximation-free control) using the transformed tracking error dynamics, which provides a proportional-like control action. Hence, the function approximators (e.g. neural networks, fuzzy systems) that are widely used to address the unknown nonlinearities in the nonlinear control designs are not needed. The proposed control design leads to a robust yet simplified function approximation-free control for nonlinear systems. The closed-loop system stability and the control error convergence are all rigorously proved. Finally, comparative simulations are conducted based on nonlinear missile systems to validate the improved response and the robustness of the proposed control method.

  19. Reactionless robust finite-time control for manipulation of passive objects by free-floating space robots

    International Nuclear Information System (INIS)

    Guo Sheng-Peng; Li Dong-Xu; Meng Yun-He; Fan Cai-Zhi

    2014-01-01

    On-orbit servicing requires efficient techniques for manipulating passive objects. The paper aims at developing a reactionless control method that drives the manipulator to manipulate passive objects with high precision, while inducing no disturbances to its base attitude. To this end, decomposition of the target dynamics from the base dynamics is discussed, so that they can be considered as two independent subsystems. A reactionless nonlinear controller is presented, which ensures high-precision manipulation of the targets and that the base orientation is unchanged. This is achieved by combining the robust finite-time control with the reaction null space. Finally, the performance of the proposed method is examined by comparing it with that of a reactionless PD controller and a pure finite-time controller. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  20. [Study on an Exoskeleton Hand Function Training Device].

    Science.gov (United States)

    Hu, Xin; Zhang, Ying; Li, Jicai; Yi, Jinhua; Yu, Hongliu; He, Rongrong

    2016-02-01

    Based on the structure and motion bionic principle of the normal adult fingers, biological characteristics of human hands were analyzed, and a wearable exoskeleton hand function training device for the rehabilitation of stroke patients or patients with hand trauma was designed. This device includes the exoskeleton mechanical structure and the electromyography (EMG) control system. With adjustable mechanism, the device was capable to fit different finger lengths, and by capturing the EMG of the users' contralateral limb, the motion state of the exoskeleton hand was controlled. Then driven by the device, the user's fingers conducting adduction/abduction rehabilitation training was carried out. Finally, the mechanical properties and training effect of the exoskeleton hand were verified through mechanism simulation and the experiments on the experimental prototype of the wearable exoskeleton hand function training device.

  1. Hands in space: gesture interaction with augmented-reality interfaces.

    Science.gov (United States)

    Billinghurst, Mark; Piumsomboon, Tham; Huidong Bai

    2014-01-01

    Researchers at the Human Interface Technology Laboratory New Zealand (HIT Lab NZ) are investigating free-hand gestures for natural interaction with augmented-reality interfaces. They've applied the results to systems for desktop computers and mobile devices.

  2. The Challenges of Precision Medicine in COPD.

    Science.gov (United States)

    Cazzola, Mario; Calzetta, Luigino; Rogliani, Paola; Matera, Maria Gabriella

    2017-08-01

    Pheno-/endotyping chronic obstructive pulmonary disease (COPD) is really important because it provides patients with precise and personalized medicine. The central concept of precision medicine is to take individual variability into account when making management decisions. Precision medicine should ensure that patients get the right treatment at the right dose at the right time, with minimum harmful consequences and maximum efficacy. Ideally, we should search for genetic and molecular biomarker-based profiles. Given the clinical complexity of COPD, it seems likely that a panel of several biomarkers will be required to characterize pathogenetic factors and their course over time. The need for biomarkers to guide the clinical care of individuals with COPD and to enhance the possibilities of success in drug development is clear and urgent, but biomarker development is tremendously challenging and expensive, and translation of research efforts to date has been largely ineffective. Furthermore, the development of personalized treatments will require a much more detailed understanding of the clinical and biological heterogeneity of COPD. Therefore, we are still far from being able to apply precision medicine in COPD and the treatable traits and FEV 1 -free approaches are attempts to precision medicine in COPD that must be considered still quite unsophisticated.

  3. Clean Hands Count

    Medline Plus

    Full Text Available ... CDC) 97,825 views 5:12 CDC Flu Education Video - Duration: 10:26. Nicole Shelton 213 views ... Infection Control Video - Duration: 20:55. Paramedical Services Education Page 4,735 views 20:55 Hand Washing ...

  4. Seismic Motion Stability, Measurement and Precision Control.

    Science.gov (United States)

    1979-12-01

    azimuth reference used for precision alignment of test fixtures and components is a porro prism mounted within the inner labora- tory. The orientation of...14 6.2 Low Frequency Tilt Loop. .................... 15 6.3 Mechanical Resonances . ..................... 17 6.4 Seismometer Matching...this prism is ascertained, using autocollimating theodolites, either by directly "swinging" Polaris into the laboratory from outside through optical

  5. Effects of Computer-Aided Manufacturing Technology on Precision of Clinical Metal-Free Restorations

    Directory of Open Access Journals (Sweden)

    Ki-Hong Lee

    2015-01-01

    Full Text Available Purpose. The purpose of this study was to investigate the marginal fit of metal-free crowns made by three different computer-aided design/computer-aided manufacturing (CAD/CAM systems. Materials and Methods. The maxillary left first premolar of a dentiform was prepared for all-ceramic crown restoration. Thirty all-ceramic premolar crowns were made, ten each manufactured by the Lava system, Cercon, and Cerec. Ten metal ceramic gold (MCG crowns served as control. The marginal gap of each sample was measured under a stereoscopic microscope at 75x magnification after cementation. One-way ANOVA and the Duncan’s post hoc test were used for data analysis at the significance level of 0.05. Results. The mean (standard deviation marginal gaps were 70.5 (34.4 μm for the MCG crowns, 87.2 (22.8 μm for Lava, 58.5 (17.6 μm for Cercon, and 72.3 (30.8 μm for Cerec. There were no significant differences in the marginal fit among the groups except that the Cercon crowns had significantly smaller marginal gaps than the Lava crowns (P<0.001.  Conclusions. Within the limitation of this study, all the metal-free restorations made by the digital CAD/CAM systems had clinically acceptable marginal accuracy.

  6. Research on Control Strategy of Free-Piston Stirling Power Generating System

    Directory of Open Access Journals (Sweden)

    Jigui Zheng

    2017-10-01

    Full Text Available As a clean and fuel adaptive alternative power plant, the Stirling power generating system has drawn attention of experts and scholars in the energy field. In practical application, the instability of free-piston Stirling power generating system caused by abrupt load change is an inevitable problem. Thus, methods to improve the output frequency response and stability of the free-piston Stirling power generating system are necessary. The model of free-piston Stirling power generating system is built by isothermal analysis firstly, and the initial control strategy based on given voltage system is put forward. To further improve the performance of power system, a current feedback decoupling control strategy is proposed, and the mathematical model is established. The influence of full decoupled quadrature-direct (d-q axis currents is analyzed with respect to the output voltage adjusting time and fluctuation amplitude under the variations of piston displacement and output load. The simulation results show that the system performance is significantly improved, but the dynamic regulation lags caused by the decoupled current control still exist. To solve this problem and improve the performance of decoupled-state feedback current control that relies on parameter accuracy, internal model control based on sliding mode (IMC-SM current decoupling control strategy is proposed, the system model is established, and then the performance of voltage ripple in generating mode is improved. Finally, the test bench is built, and the steady state and transient voltage control performances are tested. The feasibility and priority of the control strategy is verified by experiment and simulation results.

  7. Evolution and Engineering of Precisely Controlled Ge Nanostructures on Scalable Array of Ordered Si Nano-pillars

    Science.gov (United States)

    Wang, Shuguang; Zhou, Tong; Li, Dehui; Zhong, Zhenyang

    2016-06-01

    The scalable array of ordered nano-pillars with precisely controllable quantum nanostructures (QNs) are ideal candidates for the exploration of the fundamental features of cavity quantum electrodynamics. It also has a great potential in the applications of innovative nano-optoelectronic devices for the future quantum communication and integrated photon circuits. Here, we present a synthesis of such hybrid system in combination of the nanosphere lithography and the self-assembly during heteroepitaxy. The precise positioning and controllable evolution of self-assembled Ge QNs, including quantum dot necklace(QDN), QD molecule(QDM) and quantum ring(QR), on Si nano-pillars are readily achieved. Considering the strain relaxation and the non-uniform Ge growth due to the thickness-dependent and anisotropic surface diffusion of adatoms on the pillars, the comprehensive scenario of the Ge growth on Si pillars is discovered. It clarifies the inherent mechanism underlying the controllable growth of the QNs on the pillar. Moreover, it inspires a deliberate two-step growth procedure to engineer the controllable QNs on the pillar. Our results pave a promising avenue to the achievement of desired nano-pillar-QNs system that facilitates the strong light-matter interaction due to both spectra and spatial coupling between the QNs and the cavity modes of a single pillar and the periodic pillars.

  8. Modeling and Positioning of a PZT Precision Drive System

    Directory of Open Access Journals (Sweden)

    Che Liu

    2017-11-01

    Full Text Available The fact that piezoelectric ceramic transducer (PZT precision drive systems in 3D printing are faced with nonlinear problems with respect to positioning, such as hysteresis and creep, has had an extremely negative impact on the precision of laser focusing systems. To eliminate the impact of PZT nonlinearity during precision drive movement, mathematical modeling and theoretical analyses of each module comprising the system were carried out in this study, a micro-displacement measurement circuit based on Position Sensitive Detector (PSD is constructed, followed by the establishment of system closed-loop control and creep control models. An XL-80 laser interferometer (Renishaw, Wotton-under-Edge, UK was used to measure the performance of the precision drive system, showing that system modeling and control algorithms were correct, with the requirements for precision positioning of the drive system satisfied.

  9. Modeling and Positioning of a PZT Precision Drive System.

    Science.gov (United States)

    Liu, Che; Guo, Yanling

    2017-11-08

    The fact that piezoelectric ceramic transducer (PZT) precision drive systems in 3D printing are faced with nonlinear problems with respect to positioning, such as hysteresis and creep, has had an extremely negative impact on the precision of laser focusing systems. To eliminate the impact of PZT nonlinearity during precision drive movement, mathematical modeling and theoretical analyses of each module comprising the system were carried out in this study, a micro-displacement measurement circuit based on Position Sensitive Detector (PSD) is constructed, followed by the establishment of system closed-loop control and creep control models. An XL-80 laser interferometer (Renishaw, Wotton-under-Edge, UK) was used to measure the performance of the precision drive system, showing that system modeling and control algorithms were correct, with the requirements for precision positioning of the drive system satisfied.

  10. Low temperature carrier transport properties in isotopically controlled germanium

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Kohei [Univ. of California, Berkeley, CA (United States)

    1994-12-01

    Investigations of electronic and optical properties of semiconductors often require specimens with extremely homogeneous dopant distributions and precisely controlled net-carrier concentrations and compensation ratios. The previous difficulties in fabricating such samples are overcome as reported in this thesis by growing high-purity Ge single crystals of controlled 75Ge and 70Ge isotopic compositions, and doping these crystals by the neutron transmutation doping (NTD) technique. The resulting net-impurity concentrations and the compensation ratios are precisely determined by the thermal neutron fluence and the [74Ge]/[70Ge] ratios of the starting Ge materials, respectively. This method also guarantees unprecedented doping uniformity. Using such samples the authors have conducted four types of electron (hole) transport studies probing the nature of (1) free carrier scattering by neutral impurities, (2) free carrier scattering by ionized impurities, (3) low temperature hopping conduction, and (4) free carrier transport in samples close to the metal-insulator transition.

  11. Contactless and pose invariant biometric identification using hand surface.

    Science.gov (United States)

    Kanhangad, Vivek; Kumar, Ajay; Zhang, David

    2011-05-01

    This paper presents a novel approach for hand matching that achieves significantly improved performance even in the presence of large hand pose variations. The proposed method utilizes a 3-D digitizer to simultaneously acquire intensity and range images of the user's hand presented to the system in an arbitrary pose. The approach involves determination of the orientation of the hand in 3-D space followed by pose normalization of the acquired 3-D and 2-D hand images. Multimodal (2-D as well as 3-D) palmprint and hand geometry features, which are simultaneously extracted from the user's pose normalized textured 3-D hand, are used for matching. Individual matching scores are then combined using a new dynamic fusion strategy. Our experimental results on the database of 114 subjects with significant pose variations yielded encouraging results. Consistent (across various hand features considered) performance improvement achieved with the pose correction demonstrates the usefulness of the proposed approach for hand based biometric systems with unconstrained and contact-free imaging. The experimental results also suggest that the dynamic fusion approach employed in this work helps to achieve performance improvement of 60% (in terms of EER) over the case when matching scores are combined using the weighted sum rule.

  12. Conducting Original, Hands-On Astronomical Research in the Classroom

    Science.gov (United States)

    Corneau, M. J.

    2009-12-01

    teachers to convey moderately complex computer science, optical, geographic, mathematical, informational and physical principles through hands-on telescope operations. In addition to the general studies aspects of classroom internet-based astronomy, Tzec Maun supports real science by enabling operators precisely point telescopes and acquire extremely faint, magnitude 19+ CCD images. Thanks to the creative Team of Photometrica (photometrica.org), my teams now have the ability to process and analyze images online and produce results in short order. Normally, astronomical data analysis packages cost greater than thousands of dollars for single license operations. Free to my team members, Photometrica allows students to upload their data to a cloud computing server and read precise photometric and/or astrometric results. I’m indebted to Michael and Geir for their support. The efficacy of student-based research is well documented. The Council on Undergraduate Research defines student research as, "an inquiry or investigation conducted by an undergraduate that makes an original intellectual or creative contribution to the discipline." (http://serc.carleton.edu/introgeo/studentresearch/What. Teaching from Tzec Maun in the classroom is the most original teaching research I can imagine. I very much look forward to presenting this program to the convened body.

  13. Cognition-Based Approaches for High-Precision Text Mining

    Science.gov (United States)

    Shannon, George John

    2017-01-01

    This research improves the precision of information extraction from free-form text via the use of cognitive-based approaches to natural language processing (NLP). Cognitive-based approaches are an important, and relatively new, area of research in NLP and search, as well as linguistics. Cognitive approaches enable significant improvements in both…

  14. Calorimeters for Precision Power Dissipation Measurements on Controlled-Temperature Superconducting Radiofrequency Samples

    International Nuclear Information System (INIS)

    Xiao, Binping P.; Kelley, Michael J.; Reece, Charles E.; Phillips, H. L.

    2012-01-01

    Two calorimeters, with stainless steel and Cu as the thermal path material for high precision and high power versions, respectively, have been designed and commissioned for the surface impedance characterization (SIC) system at Jefferson Lab to provide low temperature control and measurement for CW power up to 22 W on a 5 cm dia. disk sample which is thermally isolated from the RF portion of the system. A power compensation method has been developed to measure the RF induced power on the sample. Simulation and experimental results show that with these two calorimeters, the whole thermal range of interest for superconducting radiofrequency (SRF) materials has been covered. The power measurement error in the interested power range is within 1.2% and 2.7% for the high precision and high power versions, respectively. Temperature distributions on the sample surface for both versions have been simulated and the accuracy of sample temperature measurements have been analysed. Both versions have the ability to accept bulk superconductors and thin film superconducting samples with a variety of substrate materials such as Al, Al 2 O 3 , Cu, MgO, Nb and Si

  15. Humans can integrate feedback of discrete events in their sensorimotor control of a robotic hand.

    Science.gov (United States)

    Cipriani, Christian; Segil, Jacob L; Clemente, Francesco; ff Weir, Richard F; Edin, Benoni

    2014-11-01

    Providing functionally effective sensory feedback to users of prosthetics is a largely unsolved challenge. Traditional solutions require high band-widths for providing feedback for the control of manipulation and yet have been largely unsuccessful. In this study, we have explored a strategy that relies on temporally discrete sensory feedback that is technically simple to provide. According to the Discrete Event-driven Sensory feedback Control (DESC) policy, motor tasks in humans are organized in phases delimited by means of sensory encoded discrete mechanical events. To explore the applicability of DESC for control, we designed a paradigm in which healthy humans operated an artificial robot hand to lift and replace an instrumented object, a task that can readily be learned and mastered under visual control. Assuming that the central nervous system of humans naturally organizes motor tasks based on a strategy akin to DESC, we delivered short-lasting vibrotactile feedback related to events that are known to forcefully affect progression of the grasp-lift-and-hold task. After training, we determined whether the artificial feedback had been integrated with the sensorimotor control by introducing short delays and we indeed observed that the participants significantly delayed subsequent phases of the task. This study thus gives support to the DESC policy hypothesis. Moreover, it demonstrates that humans can integrate temporally discrete sensory feedback while controlling an artificial hand and invites further studies in which inexpensive, noninvasive technology could be used in clever ways to provide physiologically appropriate sensory feedback in upper limb prosthetics with much lower band-width requirements than with traditional solutions.

  16. Description of precision colorimeter

    OpenAIRE

    Campos Acosta, Joaquín; Pons Aglio, Alicia; Corróns, Antonio

    1987-01-01

    Describes the use of a fully automatic, computer-controlled absolute spectroradiometer as a precision colorimeter. The chromaticity coordinates of several types of light sources have been obtained with this measurement system.

  17. Self-reported hand hygiene practices, and feasibility and acceptability of alcohol-based hand rubs among village healthcare workers in Inner Mongolia, China.

    Science.gov (United States)

    Li, Y; Wang, Y; Yan, D; Rao, C Y

    2015-08-01

    Good hand hygiene is critical to reduce the risk of healthcare-associated infections. Limited data are available on hand hygiene practices from rural healthcare systems in China. To assess the feasibility and acceptability of sanitizing hands with alcohol-based hand rubs (ABHRs) among Chinese village healthcare workers, and to assess their hand hygiene practice. Five hundred bottles of ABHR were given to village healthcare workers in Inner Mongolia, China. Standardized questionnaires collected information on their work load, availability, and usage of hand hygiene facilities, and knowledge, attitudes, and practices of hand hygiene. In all, 369 (64.2%) participants completed the questionnaire. Although 84.5% of the ABHR recipients believed that receiving the ABHR improved their hand hygiene practice, 78.8% of recipients would pay no more than US$1.5 out of their own pocket (actual cost US$4). The majority (77.2%) who provided medical care at patients' homes never carried hand rubs with them outside their clinics. In general, self-reported hand hygiene compliance was suboptimal, and the lowest compliance was 'before touching a patient'. Reported top three complaints with using ABHR were skin irritation, splashing, and unpleasant residual. Village doctors with less experience practised less hand hygiene. The overall acceptance of ABHR among the village healthcare workers is high as long as it is provided to them for free/low cost, but their overall hand hygiene practice is suboptimal. Hand hygiene education and training is needed in settings outside of traditional healthcare facilities. Published by Elsevier Ltd.

  18. Hand Gesture Recognition with Leap Motion

    OpenAIRE

    Du, Youchen; Liu, Shenglan; Feng, Lin; Chen, Menghui; Wu, Jie

    2017-01-01

    The recent introduction of depth cameras like Leap Motion Controller allows researchers to exploit the depth information to recognize hand gesture more robustly. This paper proposes a novel hand gesture recognition system with Leap Motion Controller. A series of features are extracted from Leap Motion tracking data, we feed these features along with HOG feature extracted from sensor images into a multi-class SVM classifier to recognize performed gesture, dimension reduction and feature weight...

  19. Identification of motion from multi-channel EMG signals for control of prosthetic hand

    International Nuclear Information System (INIS)

    Geethanjali, P.; Ray, K.K.

    2011-01-01

    Full text: The authors in this paper propose an effective and efficient pattern recognition technique from four channel electromyogram (EMG) signals for control of multifunction prosthetic hand. Time domain features such as mean absolute value, number of zero crossings, number of slope sign changes and waveform length are considered for pattern recognition. The patterns are classified using simple logistic regression (SLR) technique and decision tree (DT) using J48 algorithm. In this study six specific hand and wrist motions are identified from the EMG signals obtained from ten different able-bodied. By considering relevant dominant features for pattern recognition, the processing time as well as memory space of the SLR and DT classifiers is found to be less in comparison with neural network (NN), k-nearest neighbour model 1 (kNN Model-1), k-nearest neighbour model 2 (kNN-Model-2) and linear discriminant analysis. The classification accuracy of SLR classifier is found to be 91 ± 1.9%. (author)

  20. β Style Free-Piston Stirling Engine Control System Research

    Directory of Open Access Journals (Sweden)

    Xu Jian

    2016-01-01

    Full Text Available For the Free-Piston Stirling Engines (FPSE control system, a three -phase bridge circuit is reused as the system output about rectifier and start inverter. When FPSE system is in the power stage, the double closed loop control strategy and optimization algorithm of PI control parameters is adopted to ensure the highest system transmission efficiency under the requirements of the system output power and guarantee the stability of the running system. The simulation results prove the effectiveness of the above research content.