WorldWideScience

Sample records for handling unit air

  1. Development of design program for air handling units

    Energy Technology Data Exchange (ETDEWEB)

    Ham, J. K.; Kim, J. H.; Kim, Y. K.; Kim, Y. I.; Kang, P. Y. [Hyundai Heavy Industries Co., Ltd., Ulsan (Korea, Republic of)

    2000-07-01

    An Air Handling Unit(AHU) has been usually designed by manual calculations. Drawing works together with design calculations should be redone for every designing work, and also be needed to make some corrections of them. In order to design the AHU more efficiently, an AHU program has been developed. The developed program on the Windows environment is operated by the Graphic User Interface(GUI) realized using the Visual Basic Interpreter. The program provides calculation sheet of coils, weights and pressures in a MS-Excel file format as well as design drawing of the AHU in a auto CAD file format idealized by AutoLISP. Those files of the commercial softwares make easier for a designer to transfer design results to the another company for bid via e-mail.

  2. Development of design program for air handling units

    International Nuclear Information System (INIS)

    Ham, J. K.; Kim, J. H.; Kim, Y. K.; Kim, Y. I.; Kang, P. Y.

    2000-01-01

    An Air Handling Unit(AHU) has been usually designed by manual calculations. Drawing works together with design calculations should be redone for every designing work, and also be needed to make some corrections of them. In order to design the AHU more efficiently, an AHU program has been developed. The developed program on the Windows environment is operated by the Graphic User Interface(GUI) realized using the Visual Basic Interpreter. The program provides calculation sheet of coils, weights and pressures in a MS-Excel file format as well as design drawing of the AHU in a auto CAD file format idealized by AutoLISP. Those files of the commercial softwares make easier for a designer to transfer design results to the another company for bid via e-mail

  3. Development of design program for air handling units

    Energy Technology Data Exchange (ETDEWEB)

    Ham, J.K.; Kim, J.H.; Kim, Y.K.; Kim, Y.I.; Kang, P.Y. [Hyundai Heavy Industries Co., Ltd. (Korea)

    2000-11-01

    An air handling unit(AHU) has been usually designed by manual calculations. Drawing works together with design calculations should be redone for every designing work, and also be needed to make some corrections of them. In order to design the AHU more efficiently, an AHU program has been developed. The developed program on the Windows environment is operated by the graphic user interface(GUI) realized using the Visual Basic Interpreter. The program provides calculation sheet of coils, weights and pressures in a MS-Excel file format as well as design drawing of the AHU in a Auto CAD file format idealized by AutoLISP. Those files of the commercial softwares make easier for a designer to transfer design results to the another company for bid via e-mail. (author). 5 refs., 9 figs., 3 tabs.

  4. Control of the outlet air temperature in an air handling unit

    DEFF Research Database (Denmark)

    Brath, P.; Rasmussen, Henrik; Hägglund, T.

    1998-01-01

    This paper discuss modeling and control of the inlet temperature in an Air Handling Unit, AHU. The model is based on step response experiments made at a full scale test plant. We use gain scheduling to lower the correlation of the air flow with the process dynamic which simplify the control task...

  5. A rule-based fault detection method for air handling units

    Energy Technology Data Exchange (ETDEWEB)

    Schein, J.; Bushby, S. T.; Castro, N. S. [National Institute of Standards and Technology, Gaithersburg, MD (United States); House, J. M. [Iowa Energy Center, Ankeny, IA (United States)

    2006-07-01

    Air handling unit performance assessment rules (APAR) is a fault detection tool that uses a set of expert rules derived from mass and energy balances to detect faults in air handling units (AHUs). Control signals are used to determine the mode of operation of the AHU. A subset of the expert rules which correspond to that mode of operation are then evaluated to determine whether a fault exists. APAR is computationally simple enough that it can be embedded in commercial building automation and control systems and relies only upon the sensor data and control signals that are commonly available in these systems. APAR was tested using data sets collected from a 'hardware-in-the-loop' emulator and from several field sites. APAR was also embedded in commercial AHU controllers and tested in the emulator. (author)

  6. Integrating Solar Heating into an Air Handling Unit to Minimize Energy Consumption

    OpenAIRE

    Wilson, Scott A

    2010-01-01

    The purpose of this project was to test a method of integrating solar heating with a small commercial air handling unit (AHU). In order to accomplish this a heat exchanger was placed in the reheat position of the AHU and piped to the solar heating system. This heat exchanger is used to supplement or replace the existing electric reheat. This method was chosen for its ability to utilize solar energy on a more year round basis when compared to a traditional heating system. It allows solar h...

  7. Energy saving opportunity with variable speed drive in primary air-handling unit

    International Nuclear Information System (INIS)

    Li, J.S.M.

    2007-01-01

    Air conditioners used in the court buildings in Kowloon City, Hong Kong were retrofitted with variable speed drives in the primary air handling unit (PAU) in an effort to reduce energy consumption. The initial effect of this retrofit was investigated along with the feasibility of using a carbon dioxide (CO 2 ) based demand control ventilation to reduce energy consumption while optimizing indoor air quality. The air flow in most air conditioning fans is either constant or controlled by motorized inlet guide vanes. Although this controls the flow and may reduce the load on the fan, this constriction adds an energy loss, resulting in inefficient operation. Variable speed drives should be used on the PAU in order to maintain system efficiency. As the speed of the fans are reduced, the flow will decrease proportionally, while the power required by the fan will reduce the cube of the speed. Therefore, if the fresh air supply can be controlled by reducing the speed of the fan motor, then flow control would be more efficient. The energy saving associated with variable fresh air supply flow rate was evaluated along with the cost to building owners. This paper presented the results of the potential energy and cost savings associated with this retrofit, and included implementation cost and pay back period. It was estimated that about 20 per cent of power consumption and electricity costs can be saved per year, with a simple payback period of 2 years. 7 refs., 3 tabs., 3 figs

  8. Performance Assessment of a Solar-Assisted Desiccant-Based Air Handling Unit Considering Different Scenarios

    Directory of Open Access Journals (Sweden)

    Giovanni Angrisani

    2016-09-01

    Full Text Available In this paper, three alternative layouts (scenarios of an innovative solar-assisted hybrid desiccant-based air handling unit (AHU are investigated through dynamic simulations. Performance is evaluated with respect to a reference system and compared to those of the innovative plant without modifications. For each scenario, different collector types, surfaces and tilt angles are considered. The effect of the solar thermal energy surplus exploitation for other low-temperature uses is also investigated. The first alternative scenario consists of the recovery of the heat rejected by the condenser of the chiller to pre-heat the regeneration air. The second scenario considers the pre-heating of regeneration air with the warmer regeneration air exiting the desiccant wheel (DW. The last scenario provides pre-cooling of the process air before entering the DW. Results reveal that the plants with evacuated solar collectors (SC can ensure primary energy savings (15%–24% and avoid equivalent CO2 emissions (14%–22%, about 10 percentage points more than those with flat-plate collectors, when the solar thermal energy is used only for air conditioning and the collectors have the best tilt angle. If all of the solar thermal energy is considered, the best results with evacuated tube collectors are approximately 73% in terms of primary energy saving, 71% in terms of avoided equivalent CO2 emissions and a payback period of six years.

  9. The Fate of Mengovirus on Fiberglass Filter of Air Handling Units.

    Science.gov (United States)

    Bandaly, Victor; Joubert, Aurélie; Le Cann, Pierre; Andres, Yves

    2017-12-01

    One of the most important topics that occupy public health problems is the air quality. That is the reason why mechanical ventilation and air handling units (AHU) were imposed by the different governments in the collective or individual buildings. Many buildings create an artificial climate using heating, ventilation, and air-conditioning systems. Among the existing aerosols in the indoor air, we can distinguish the bioaerosol with biological nature such as bacteria, viruses, and fungi. Respiratory viral infections are a major public health issue because they are usually highly infective. We spend about 90% of our time in closed environments such as homes, workplaces, or transport. Some studies have shown that AHU contribute to the spread and transport of viral particles within buildings. The aim of this work is to study the characterization of viral bioaerosols in indoor environments and to understand the fate of mengovirus eukaryote RNA virus on glass fiber filter F7 used in AHU. In this study, a set-up close to reality of AHU system was used. The mengovirus aerosolized was characterized and measured with the electrical low pressure impact and the scanner mobility particle size and detected with RT-qPCR. The results about quantification and the level of infectivity of mengovirus on the filter and in the biosampler showed that mengovirus can pass through the filter and remain infectious upstream and downstream the system. Regarding the virus infectivity on the filter under a constant air flow, mengovirus was remained infectious during 10 h after aerosolization.

  10. Robust Sliding Mode Control of Air Handling Unit for Energy Efficiency Enhancement

    Directory of Open Access Journals (Sweden)

    Awais Shah

    2017-11-01

    Full Text Available In order to achieve feasible and copacetic low energy consuming building, a robust and efficient air conditioning system is necessary. Since heating ventilation and air conditioning systems are nonlinear and temperature and humidity are coupled, application of conventional control is inappropriate. A multi-input multi-output nonlinear model is presented. The temperature and humidity of thermal zone are ascendance by the manipulation of the water and air flow rates. A sliding mode controller (SMC is designed to ensure robust performance of air handling unit in the presence of uncertainties. A simple proportional-integral-derivative (PID controller is used as a comparison template to highlight the efficiency of the proposed controller. To accomplish tracking targets, a variety of desired temperature and relative humidity commands (including ramp and combination with sequence of steps are investigated. According to simulation results, SMC transcends the PID controller in terms of settling time, steady state and rise time, which makes SMC more energy efficient.

  11. Multivariable robust control of an air-handling unit: A comparison between pole-placement and H∞ controllers

    International Nuclear Information System (INIS)

    Moradi, Hamed; Bakhtiari-Nejad, Firooz; Saffar-Avval, Majid

    2012-01-01

    Highlights: ► Robust control of a multivariable air-handling unit (AHU). ► Controllers designed based on pole-placement and μ-synthesis. ► Robust performance in the presence of model uncertainties. ► Achievement of various tracking objectives in temperature and relative humidity. ► Comfort conditions in buildings with low energy consumption and operation cost. - Abstract: Control of air-conditioner units is essential to achieve satisfactory comfort conditions in buildings while keeping low energy consumption and operation costs. In this paper, a nonlinear multiinput and multioutput model (MIMO) of an air-handling unit (AHU) is considered. After linearization of the state equations around the operating points, an observer and a regulator are designed for the estimation of state variables and disturbance rejection, respectively. A realistic uncertain model is considered which constitutes various uncertainties associated with complex nonlinear model of AHU. In the presence of model uncertainties, a H ∞ -robust controller is designed to guarantee robust performance of the air-handling unit. In addition, a simple controller based on pole-placement approach is developed. Indoor temperature and relative humidity are controlled via manipulation of valve positions of air and cold water flow rates. Achievement of tracking objectives is investigated through various desired commands of indoor temperature and relative humidity (including a sequence of steps and ramps-steps). According to results, the H ∞ -robust controller guarantees the robust performance of the AHU in tracking of desired set-paths (while using the simple pole-placement controller leads to high oscillatory behavior of the output variables and control efforts). Moreover, using H ∞ -robust controller results in less energy consumption in comparison with the pole-placement controller.

  12. Development of a Data-Driven Predictive Model of Supply Air Temperature in an Air-Handling Unit for Conserving Energy

    Directory of Open Access Journals (Sweden)

    Goopyo Hong

    2018-02-01

    Full Text Available The purpose of this study was to develop a data-driven predictive model that can predict the supply air temperature (SAT in an air-handling unit (AHU by using a neural network. A case study was selected, and AHU operational data from December 2015 to November 2016 was collected. A data-driven predictive model was generated through an evolving process that consisted of an initial model, an optimal model, and an adaptive model. In order to develop the optimal model, input variables, the number of neurons and hidden layers, and the period of the training data set were considered. Since AHU data changes over time, an adaptive model, which has the ability to actively cope with constantly changing data, was developed. This adaptive model determined the model with the lowest mean square error (MSE of the 91 models, which had two hidden layers and sets up a 12-hour test set at every prediction. The adaptive model used recently collected data as training data and utilized the sliding window technique rather than the accumulative data method. Furthermore, additional testing was performed to validate the adaptive model using AHU data from another building. The final adaptive model predicts SAT to a root mean square error (RMSE of less than 0.6 °C.

  13. The influence of typical ways of operating and air-handling unit on the sensory pollution load from used bag filters

    DEFF Research Database (Denmark)

    Mysen, M.; Clausen, Geo; Bekö, Gabriel

    2003-01-01

    An experiment was performed to determine whether the sensory pollution emitted from a bag filter that had been used for 3 months in a suburban area in Denmark was influenced by different ways of operating the air-handling unit (AHU). Samples of the used filter were pre-conditioned to simulate thr...... the airflow outside working hours would significantly increase the sensory pollution emitted by a used bag filter immediately after the AHU is turned on, in comparison with continuous airflow through the AHU (P...... operating conditions: 1) switched off overnight; 2) airflow reduced to 10% overnight; and 3) continuous 100% operation. Outside air passed through the samples and the acceptability of the air after the filter was assessed by a panel of subjects. The results indicate that turning off the AHU or reducing...

  14. Staphylococcus xylosus PCR-validated Decontamination of Murine Individually Ventilated Cage Racks and Air Handling Units by Using ‘Active–Closed’ Exposure to Vaporized Hydrogen Peroxide

    Science.gov (United States)

    Ragland, Natalie H; Miedel, Emily L; Gomez, Jose M; Engelman, Robert W

    2017-01-01

    Vaporized hydrogen peroxide (VHP) is used to decontaminate clinical, biocontainment, and research animal rooms and equipment. To assist with its implementation in a murine facility, we developed a safe and effective method of VHP sterilization of IVC racks and air handling units (AHU). Safety of VHP decontamination was assessed by ensuring VHP levels dissipated to less than 1 ppm in the room prior to personnel reentry and inside the primary enclosure prior to the return of mice; this condition occurred at least 18 h after the VHP cycle. Efficacy of VHP sterilization was assessed by using chemical indicators, biologic indicators, and PCR testing for Staphylococcus xylosus, a commensal organism of murine skin and an opportunistic pathogen, which was present in 160 of 172 (93%) of specimens from occupied IVC racks and the interior surfaces of in-use AHU. Neither mechanized washing nor hand-sanitizing eradicated S. xylosus from equipment airway interiors, with 17% to 24% of specimens remaining PCR-positive for S. xylosus. ‘Static–open’ VHP exposure of sanitized equipment did not ensure its sterilization. In contrast, ‘active–closed’ VHP exposure, in which IVC racks were assembled, sealed, and connected to AHU set to the VHP cycle, increased the proportion of chemical indicators that detected sterilizing levels of VHP inside the assembled equipment, and significantly decreased PCR-detectable S. xylosus inside the equipment. Supplementing bulk steam sterilization of the primary enclosure with VHP sterilization of the secondary housing equipment during room change-outs may help to mitigate opportunistic agents that jeopardize studies involving immunodeficient strains. PMID:29256369

  15. Staphylococcus xylosus PCR-validated Decontamination of Murine Individually Ventilated Cage Racks and Air Handling Units by Using 'Active-Closed' Exposure to Vaporized Hydrogen Peroxide.

    Science.gov (United States)

    Ragland, Natalie H; Miedel, Emily L; Gomez, Jose M; Engelman, Robert W

    2017-11-01

    Vaporized hydrogen peroxide (VHP) is used to decontaminate clinical, biocontainment, and research animal rooms and equipment. To assist with its implementation in a murine facility, we developed a safe and effective method of VHP sterilization of IVC racks and air handling units (AHU). Safety of VHP decontamination was assessed by ensuring VHP levels dissipated to less than 1 ppm in the room prior to personnel reentry and inside the primary enclosure prior to the return of mice; this condition occurred at least 18 h after the VHP cycle. Efficacy of VHP sterilization was assessed by using chemical indicators, biologic indicators, and PCR testing for Staphylococcus xylosus, a commensal organism of murine skin and an opportunistic pathogen, which was present in 160 of 172 (93%) of specimens from occupied IVC racks and the interior surfaces of in-use AHU. Neither mechanized washing nor hand-sanitizing eradicated S. xylosus from equipment airway interiors, with 17% to 24% of specimens remaining PCR-positive for S. xylosus. 'Static-open' VHP exposure of sanitized equipment did not ensure its sterilization. In contrast, 'active-closed' VHP exposure, in which IVC racks were assembled, sealed, and connected to AHU set to the VHP cycle, increased the proportion of chemical indicators that detected sterilizing levels of VHP inside the assembled equipment, and significantly decreased PCR-detectable S. xylosus inside the equipment. Supplementing bulk steam sterilization of the primary enclosure with VHP sterilization of the secondary housing equipment during room change-outs may help to mitigate opportunistic agents that jeopardize studies involving immunodeficient strains.

  16. Air conditioner for radioactive material handling facility

    International Nuclear Information System (INIS)

    Tanaka, Takeaki.

    1991-01-01

    An air conditioner intakes open-air from an open-air intake port to remove sands and sea salt particles by air filters. Then, natural and artificial radioactive particles of less than 1 μm are removed by high performance particulate filters. After controlling the temperature by an air heater or an air cooler, air is sent to each of chambers in a facility under pressure elevation by a blower. In this case, glass fibers are used as the filter material for the high performance particulate filter, which has a performance of more than 99.97% for the particles of 0.3 μm grain size. Since this can sufficiently remove the natural radioactive materials intruded from the outside, a detection limit value in each of the chambers of the facility can be set 10 -13 to 10 -14 μci/cm 3 in respect of radiation control. Accordingly, radiation control can be conducted smoothly and appropriately. (I.N.)

  17. Evaluation of seasonal exergy efficiency of air handing unit

    Directory of Open Access Journals (Sweden)

    Kęstutis Genys

    2015-10-01

    Full Text Available The article deals with the air handling unit seasonal exergy efficiency. TRNSYS simulation tool is used to evaluate it. The object of research is air treatment device used to treat an air for the ventilation of laboratory. The mathematical model of air handling unit using TRNSYS simulation tool was developed when the technical parameters of air handling unit and energy exchange in it were analysed. The developed model according to the made observations during the warm and cold periods was tested and validation of elements was performed. The simulation of air handling unit operation after the verification of reliability and permitted tolerances was performed. The control mechanisim which allows simulating the operation of air handling unit during cold and warm periods of the year was made. The mathematical algorithm for calculation of air handling unit exergy efficiency coefficient applying the principles of exergy analysis was developed. The seasonal exergy efficiency of air handling unit equal to 3.94 percent during the simulation was obtained.

  18. Sustainable Air Handling by Evaporation and Adsorption

    NARCIS (Netherlands)

    Esfandiari Nia, F.

    2011-01-01

    A considerable fraction of today's energy consumption is due to air-conditioning of buildings, involving both heating and cooling. Energy cost and environmental concerns force designers to find sustainable solutions. Desiccant cooling as a sustainable technology is attractive to be investigated for

  19. Unit for air decontamination

    International Nuclear Information System (INIS)

    Mariano H, E.

    1991-02-01

    To fulfill the applicable requirements of safety to the ventilation systems in nuclear facilities, it is necessary to make a cleaning of the air that hurtles to the atmosphere. For that which was designed and it manufactured an unit for decontamination of the air for the Pilot plant of production of Nuclear Fuel that this built one with national parts, uses Hepa national filters and the design can adapt for different dimensions of filters, also can be added a lodging for a prefilter or to adopt two Hepa filters. (Author)

  20. Air-handling energy efficiency and design practices

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, Lars J.

    1993-12-31

    With good design practices and life-cycle cost optimization, specific fan power for individual fans will be between 0.5 and 1kW/m{sup 3}/s. Data from nearly 1000 audited fans in Sweden show that the average measured SFPI weighted by drawn motor power is 1.5 kW/m{sup 3}/s and the situation appears to be similar in other countries. Contract forms used by Swedish builders, and consultants` design practices are analyzed here to search for an explanation to the low performance of installed systems. Identified as two major barriers to efficient system design are the lack of performance specifications when procuring systems and the incentive structure in the building sector. As a consequence, duct design methods, rules of thumb, and vendor recommendations are not leading to system optimization. The broad minima in life cycle costs over a range of air-handling unit sizes show that potential economic welfare losses from efficiency standards are likely to be smaller than the losses that result from today`s design practices. 73 refs, 4 figs, 3 tabs

  1. Air-handling energy efficiency and design practices

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, Lars J

    1994-12-31

    With good design practices and life-cycle cost optimization, specific fan power for individual fans will be between 0.5 and 1kW/m{sup 3}/s. Data from nearly 1000 audited fans in Sweden show that the average measured SFPI weighted by drawn motor power is 1.5 kW/m{sup 3}/s and the situation appears to be similar in other countries. Contract forms used by Swedish builders, and consultants` design practices are analyzed here to search for an explanation to the low performance of installed systems. Identified as two major barriers to efficient system design are the lack of performance specifications when procuring systems and the incentive structure in the building sector. As a consequence, duct design methods, rules of thumb, and vendor recommendations are not leading to system optimization. The broad minima in life cycle costs over a range of air-handling unit sizes show that potential economic welfare losses from efficiency standards are likely to be smaller than the losses that result from today`s design practices. 73 refs, 4 figs, 3 tabs

  2. Acoustophoretic contactless transport and handling of matter in air.

    Science.gov (United States)

    Foresti, Daniele; Nabavi, Majid; Klingauf, Mirko; Ferrari, Aldo; Poulikakos, Dimos

    2013-07-30

    Levitation and controlled motion of matter in air have a wealth of potential applications ranging from materials processing to biochemistry and pharmaceuticals. We present a unique acoustophoretic concept for the contactless transport and handling of matter in air. Spatiotemporal modulation of the levitation acoustic field allows continuous planar transport and processing of multiple objects, from near-spherical (volume of 0.1-10 μL) to wire-like, without being limited by the acoustic wavelength. The independence of the handling principle from special material properties (magnetic, optical, or electrical) is illustrated with a wide palette of application experiments, such as contactless droplet coalescence and mixing, solid-liquid encapsulation, absorption, dissolution, and DNA transfection. More than a century after the pioneering work of Lord Rayleigh on acoustic radiation pressure, a path-breaking concept is proposed to harvest the significant benefits of acoustic levitation in air.

  3. Shift designs for freight handling personnel at air cargo terminals

    DEFF Research Database (Denmark)

    Rong, Aiying; Grunow, Martin

    2009-01-01

    This paper presents an integrated mixed integer linear programming (MILP) model for determining manpower requirements and related personnel shift designs for the build-up and break-down of the unit load devices (ULDs) at the air cargo terminal to minimize manpower costs. To utilize the manpower...... resources efficiently, we implement a new mechanism for demand leveling. In addition, we consider the qualification hierarchy between build-up and break-down workers. A case study based on the real-life data shows that the model is useful for manpower planning at air cargo terminals and the integrated...

  4. A bag adapted for the handling of a filtering element or filter unit

    International Nuclear Information System (INIS)

    Marshall, D.A.G.

    1980-01-01

    The invention relates to a transparent, flexible, synthetic plastics bag adapted to contain a filter element or filter unit so that the latter can be inserted into or removed from a filter casing or duct while being contained in the bag. The bag has a neck portion which is capable of being removably secured in an air-tight manner on to a part of the casing, and gloves or glove portions are provided in, or are formed in, the wall of the bag to permit handles on the filter element or unit to be grasped. (author)

  5. Dynamic simulation of the NET In-Vessel Handling Unit

    International Nuclear Information System (INIS)

    Reim, J.

    1991-01-01

    During the conceptual design phase of the Next European Torus (NET) a large remote maintenance transporter system, the In-Vessel Handling Unit (IVHU), is being developed. It consists of an articulated boom with four rotational joints, which is mounted on a carrier outside the vessel. This boom will be able to carry master-slave manipulators or special work units. The engineering design is supported by dynamic computations. Main topics of the dynamic simulation are the evaluation of IVHU performance, selection and optimisation of the actuator design and of the control algorithms. This simulation task requires full three-dimensional modelling regarding structural elasticity and non-linear actuator dynamics. The Multibody dynamics of the transporter system are modelled with a commerical analysis package. Elastic links and a precise dynamic actuator model are introduced by applied forces, spring elements and differential equations. The actuator model comprises electric motors, gears and linear control algorithms. Non-linear effects which have an influence on control stability and accuracy are taken into account. Most important effects are backlash and static friction. The simulations concentrate on test and optimisation of the control layout and performance studies for critical remote handling tasks. Simulations for control layout and critical remote maintenance tasks correspond to the design objectives of the transporter system. (orig.)

  6. Ball handling system for tech united soccer robots

    NARCIS (Netherlands)

    Gerrits, K.P.; Molengraft, van de M.J.G.; Hoogendijk, R.; Steinbuch, M.

    2012-01-01

    This pre-master end project is done for team Tech United of Eindhoven University of Technology. The Tech United team is a group of students and employees who design, build and program soccer robots to compete in the RoboCup Middle Size League. RoboCup is a worldwide competition in which two teams of

  7. Technical specifications of air handling system of the inspection of a field

    International Nuclear Information System (INIS)

    Kim, Seon Duk; Bang, Hong Sik; Oh, Yon Woo

    2002-07-01

    A T.A.B(Testing, Adjusting and Balancing) technique, the basic technique of air handling facility, is one of the essential technical items which workers in charge of operation of facilities have to acquire. Especially, through scientific and reasonable inspective procedures, the reduction of energy and guarantee of designed skill have become influential important problems in our time rather than in the past days. Entrepreneurs have required more thorough verify of performances and procedure of test in order to raise the investment efficiency and reduce expenditure. For that reason, I hope that co-operator acquire objective and substantial knowledges about air handling facility so that they are helped from them

  8. Technical on the TAB of air handling system in IMEF facility

    International Nuclear Information System (INIS)

    Oh, Yon Woo; Baik, S. Y.; Kim, S. D.; Lee, B. J.

    2002-08-01

    A T.A.B(Testing, Adjusting and Balancing) technique, the basic technique of air handling facility, is one of the essential technical items which workers in charge of operation of facilities have to acquire. Especially, through scientific and reasonable inspective procedures, the reduction of energy and guarantee of designed skill have become influential important problems in our time rather than in the past days. Entrepreneurs have required more thorough verify of performances and procedure of test in order to raise the investment efficiency and reduce expenditure. For that reason, I hope that cooperator acquire objective and substantial knowledges about air handling facility so that they are helped from them

  9. INDOOR AIR CONCENTRATION UNIT CONVERSIONS

    Science.gov (United States)

    Migration of volatile chemicals from the subsurface into overlying buildings is called vapor intrusion (VI). Volatile organic chemicals in contaminated soils or groundwater can emit vapors, which can migrate through subsurface soils and may enter the indoor air of overlying buil...

  10. The Application of Online Check-in in the Process of Passenger Handling in Air Transportation

    Directory of Open Access Journals (Sweden)

    František Adamčík

    2017-11-01

    Full Text Available Passenger handling is one of the most important activities any passenger is obliged to carry out prior to boarding the plane to depart. For the handling process to be safeguarded, it is inevitable to perform the services involved in it fast and efficiently so as to prevent idle times or delays during the procedures potentially resulting in delay of flight. By gradual development of the so-called web-based information technologies, some of the activities involved in the handling process can be delegated to the passengers themselves, thereby achieving a faster course of the passenger handling process. In this contribution the authors are dealing with the status quo of the on-line web-based check-in process in air transportation forecasting the expected course of events in these services in the future. Next, based on analyzing functions and characteristics of similar solutions available in the market, the authors are putting forward their new proposal of their own design of a self-service, on-line system of passenger handling with the aim to simplify and expedite the entire handling process. It is the aim of the authors to develop a competitive design in terms of costs as well as new function and services not offered by the hitherto existing with emphasis on improving efficiency of passenger handling at the airports. The resulting solution thanks to internet based technologies is platform independent and fully applicable to the process of airport passenger handling. To an equal extent, the solutions are being applied by the authors to the educational process, as a training tool for the preparation of the aviation personnel and also as part of simulation models for research in the field of airport processes optimization.

  11. The FMEA Analysis for Fuel Handling System at Cernavoda Unit 2

    International Nuclear Information System (INIS)

    Park, Jin Hee; Kim, Tae Woon; Rhee, Bo Wook; Yoon, Chul; Kim, Hyeong Tae; Cho, In Gil; Kim, Seong Ho

    2006-01-01

    A Nuclear Safety Evaluation was performed by an independent assessor at the request of the regulatory authority CNCAN (Comisia Nationala pentru Controlul Activitatilor Nucleare. National Committee for Nuclear Activities Control in Romania) to provide an independent overview of all the nuclear safety aspects of Cernavoda Unit 2 under construction and an expert opinion whether the completed Cernavoda Unit-2 Nuclear Power Plant would satisfy current Western European nuclear safety objectives and practices. A report was produced (Cernavoda 2 Nuclear Safety Expert Project, 'Task 10 . Safety Evaluation Report', A.F.Parsons, NNC Limited, December 2001) and contains recommendations either mandatory or advisory. The FMEA study, one of the mandatory recommendations, is performing now for fuel handling system and radioactive waste handling system for Cernavoda unit 2 in Romania sponsored by KHNP. In this paper, only the FMEA study for fuel handling system is presented

  12. Air pollution problem in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Heimann, H

    1964-10-01

    Air pollution in the United States as a problem affecting health, as well as man's enjoyment of his property, was first noted in 1912 in the reports of the investigators at the Mellon Institute of the University of Pittsburgh. The Selby copper smelter incident in 1915 was among the first episodic air pollution events documented. The US Public Health Service studied carbon monoxide buildup in vehicular tunnels in 1928 and 1929. the Donora (Pennsylvania) pollution episode, where 17 people died, occurred in 1949. It and the onset of smog conditions in the Los Angeles area really initiated broad public awareness of air pollution as a public health hazard in the USA. The symptoms of air pollution-related injuries are discussed, the role of the US Public Health Service in dealing with air pollution, and the effect of the Clean Air Act of 1963 are discussed. 26 references.

  13. A case study on determining air monitoring requirements in a radioactive materials handling area

    International Nuclear Information System (INIS)

    Newton, G.J.; Bechtold, W.E.; Hoover, M.D.; Ghanbari, F.; Herring, P.S.; Jow, Hong-Nian

    1993-01-01

    A technical, defensible basis for the number and placement of air sampling instruments in a radioactive materials handling facility was developed. Historical air sampling data, process and physicochemical knowledge, qualitative smoke dispersion studies with video documentation, and quantitative trace gas dispersion studies were used to develop a strategy for number and placement of air samplers. These approaches can be used in other facilities to provide a basis for operational decisions. The requirements for retrospective sampling, personal sampling, and real-time monitoring are included. Other relevant operational decisions include selecting the numbers, placement, and appropriate sampling rates for instruments, identifying areas of stagnation or recirculation, and determining the adequacy and efficiency of any sampling transport lines. Justification is presented for using a graded approach to characterizing the workplace and determining air sampling and monitoring needs

  14. An Investigation of Technologies for Hazardous Sludge Reduction at AFLC (Air Force Logistics Command) Industrial Waste Treatment Plants. Volume 1. Sodium Borohydride Treatment and Sludge Handling Technologies.

    Science.gov (United States)

    1983-12-01

    Fisher Cupric sulfate-CuSO 4 . 5H20, Certified ACS Fisher Sodium Bicarbonate-NaHCO3, Certified ACS Fisher NaOH-Certified ACS Electrolytic Pellets , Fisher...The dryer (D-1), burner , and air handling system are part of a package unit including a 4-foot diameter by 24 foot long free-standing rotary dryer, a...blower with a rated capacity of 6,200 scfm of air at 500C, a burner capable of heating that volume of air to 125*C and a cyclonic dust separator to

  15. ENVIRONMENTAL SAMPLING USING LOCATION SPECIFIC AIR MONITORING IN BULK HANDLING FACILITIES

    Energy Technology Data Exchange (ETDEWEB)

    Sexton, L.; Hanks, D.; Degange, J.; Brant, H.; Hall, G.; Cable-Dunlap, P.; Anderson, B.

    2011-06-07

    Since the introduction of safeguards strengthening measures approved by the International Atomic Energy Agency (IAEA) Board of Governors (1992-1997), international nuclear safeguards inspectors have been able to utilize environmental sampling (ES) (e.g. deposited particulates, air, water, vegetation, sediments, soil and biota) in their safeguarding approaches at bulk uranium/plutonium handling facilities. Enhancements of environmental sampling techniques used by the IAEA in drawing conclusions concerning the absence of undeclared nuclear materials or activities will soon be able to take advantage of a recent step change improvement in the gathering and analysis of air samples at these facilities. Location specific air monitoring feasibility tests have been performed with excellent results in determining attribute and isotopic composition of chemical elements present in an actual test-bed sample. Isotopic analysis of collected particles from an Aerosol Contaminant Extractor (ACE) collection, was performed with the standard bulk sampling protocol used throughout the IAEA network of analytical laboratories (NWAL). The results yielded bulk isotopic values expected for the operations. Advanced designs of air monitoring instruments such as the ACE may be used in gas centrifuge enrichment plants (GCEP) to detect the production of highly enriched uranium (HEU) or enrichments not declared by a State. Researchers at Savannah River National Laboratory in collaboration with Oak Ridge National Laboratory are developing the next generation of ES equipment for air grab and constant samples that could become an important addition to the international nuclear safeguards inspector's toolkit. Location specific air monitoring to be used to establish a baseline environmental signature of a particular facility employed for comparison of consistencies in declared operations will be described in this paper. Implementation of air monitoring will be contrasted against the use of smear

  16. Unit for air decontamination; Unidad para descontaminacion de aire

    Energy Technology Data Exchange (ETDEWEB)

    Mariano H, E

    1991-02-15

    To fulfill the applicable requirements of safety to the ventilation systems in nuclear facilities, it is necessary to make a cleaning of the air that hurtles to the atmosphere. For that which was designed and it manufactured an unit for decontamination of the air for the Pilot plant of production of Nuclear Fuel that this built one with national parts, uses Hepa national filters and the design can adapt for different dimensions of filters, also can be added a lodging for a prefilter or to adopt two Hepa filters. (Author)

  17. Converting Constant Volume, Multizone Air Handling Systems to Energy Efficient Variable Air Volume Multizone Systems

    Science.gov (United States)

    2017-06-05

    Wallace 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING...28  8.2.2  Zone Heating or Cooling Load Imbalance ...Ft. Bragg ........ 24  Table 12. Reduction in Life Cycle Energy Costs for Incremental Retrofits ................................. 25  Table 13. Simple

  18. Optimization of the DEC-air handling process. Final report; Optimierung der Komponenten des DEC-Klimasystems. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Franzke, U.; Stangl, M.

    2000-02-15

    The energy consumption of buildings caused by air conditioning is high. The main reason is the using of refrigeration machines for dehumidification under the dew point. A reduction of the energy consumption is possible in case of using of desiccant dehumidification. A desiccant cooling air handling unit realizes the dehumidification by desiccants. Further more a heat recovery wheel and a humidifier are necessary. In the framework of the project the desiccant wheel and a high-pressure humidifier are investigated. A refrigeration machine was installed only for theoretical investigations. The investigation was done in the theoretical and experimental way. A new simulation model was developed. The measurement values are used for the verification of the mathematical simulation. In the framework of the project the performance characteristics of the desiccant wheel and the humidifier are optimized. As a result the regeneration temperature is now lower than at the beginning of the work. The humidifier capacity is in the same range at lower fresh water consumption. The components of the desiccant cooling air-handling unit were optimized according their performance characteristic. For the company Klingenburg the market chances will increase in case of more applications. (orig.) [German] Die Klimatisierung von Gebaeuden ist in aller Regel mit einem grossen Energieaufwand verbunden. Hauptursache dafuer ist die Verwendung der Entfeuchtung durch Taupunktunterschreitung unter Nutzung von Kaeltemaschinen. Eine Verringerung des Energieaufwandes ist nur durch Einsatz der sorptiven Luftentfeuchtung moeglich. Eine DEC-Klimaanlage realisiert die Luftentfeuchtung mit Hilfe der Sorption. Sie setzt sich aus verschiedenen Komponenten zusammen. Im Rahmen des Forschungsvorhabens wurden besonders der Sorptionsregenerator und der Kaltdampfgenerator sowohl experimentell als auch theoretisch untersucht und optimiert. Als ergaenzende Systemkomponente kommt die Kaeltemaschine hinzu, die jedoch

  19. Thermal response of a can handling unit (CHU) to a postulated plutonium hydride burn

    International Nuclear Information System (INIS)

    Crea, B.A.; Heard, F.J.

    1998-01-01

    A series of analyses were performed to support the design of the Can Handling Unit (CHU). The subject analyses focused on determining the time to repressurize a subatmospheric storage can containing plutonium metal versus the initial hole size and the transient thermal response to a postulated chemical reaction of 150 grams of plutonium hydride. Limiting the amount of gaseous reactants either by inerting the CHU or using a very small hole size for the initial opening appears to be a viable method of controlling the rate of the exothermic chemical reactions and system temperatures

  20. Lessons learnt from the market for air freight ground handling at Amsterdam Airport Schiphol

    NARCIS (Netherlands)

    Burghouwt, G.; Poort, J.; Ritsema, H.

    2014-01-01

    On 16 April 2013, the European Parliament adopted a new, amended airport ground handling Regulation, which will replace the old Directive 96/67 EC on ground handling services. The new Regulation will further open up European airports for competition on the ground handling market. Even long before

  1. The making of automation air fiddling unit (AHU) for G 71 cooler system

    International Nuclear Information System (INIS)

    Suripto

    2003-01-01

    A design of the making automation of air handling unit (AHU) for G. 71 cooler system at the design it has been conducted AHU operational time programming for G. 71 cooler system, when applied if will operate as programmed. flopefully, it mill save electric power and the dependency to the operator can be reduced significantly therefore it will increase efficiency and optimization in the usage of the cooler system. At the and if will reduce and save operational cost mainly in maintenance cost

  2. Preventive maintenance basis: Volume 21 -- HVAC, air handling equipment. Final report

    International Nuclear Information System (INIS)

    Worledge, D.; Hinchcliffe, G.

    1997-12-01

    US nuclear plants are implementing preventive maintenance (PM) tasks with little documented basis beyond fundamental vendor information to support the tasks or their intervals. The Preventive Maintenance Basis project provides utilities with the technical basis for PM tasks and task intervals associated with 40 specific components such as valves, electric motors, pumps, and HVAC equipment. This report provides an overview of the PM Basis project and describes use of the PM Basis database. Volume 21 of the report provides a program of PM tasks suitable for application to HVAC-Air Handling Equipment. The PM tasks that are recommended provide a cost-effective way to intercept the causes and mechanisms that lead to degradation and failure. They can be used, in conjunction with material from other sources, to develop a complete PM program or to improve an existing program. Users of this information will be utility managers, supervisors, craft technicians, and training instructors responsible for developing, optimizing, or fine-tuning PM programs

  3. Radioactive Air Emission Notice of Construction for (NOC) Plutonium Finishing Plant (PFP) Project W-460 Plutonium Stabilization and Handling

    International Nuclear Information System (INIS)

    JANSKY, M.T.

    2000-01-01

    The following description and any attachments and references are provided to the Washington State Department of Health (WDOH), Division of Radiation Protection, Air Emissions and Defense Waste Section as a notice of construction (NOC) in accordance with Washington Administrative Code (WAC) 246-247, Radiation Protection-Air Emissions. The WAC 246-247-060, ''Applications, registration, and licensing'', states ''This section describes the information requirements for approval to construct, modify, and operate an emission unit. Any NOC requires the submittal of information listed in Appendix A,'' Appendix A (WAC 246-247-1 IO) lists the requirements that must be addressed. Additionally, the following description, attachments, and references are provided to the U.S. Environmental Protection Agency (EPA) as an NOC, in accordance with Title 40 Code of Federal Regulations (CFR), Part 61, ''National Emission Standards for Hazardous Air Pollutants.'' The information required for submittal to the EPA is specified in 40 CFR 61.07. The potential emissions from this activity are estimated to provide greater than 0.1 millirem year total effective dose equivalent (TEDE) to the hypothetical offsite maximally exposed individual (MEI) and commencement is needed within a short time. Therefore, this application also is intended to provide notification of the anticipated date of initial startup in accordance with the requirement listed in 40 CFR 61.09(a)(1), and it is requested that approval of this application also constitutes EPA acceptance of this initial startup notification. Written notification of the actual date of initial startup, in accordance with the requirement listed in 40 CFR 61.09(a)(2), will be provided later. This NOC covers the activities associated with the construction and operation activities involving stabilization and/or repackaging of plutonium in the 2736-ZB Building. An operations support trailer will be installed in the proximity of the 2736-ZB Building. A new

  4. AIRS/Aqua Level 3 Pentad quantization in physical units (AIRS-only) V005

    Data.gov (United States)

    National Aeronautics and Space Administration — AIRS/Aqua Level 3 pentad quantization product in physical units (AIRS Only). The quantization products (QP) are distributional summaries derived from the Level-2...

  5. The United States Air Force in Southeast Asia: Tactical Airlift

    Science.gov (United States)

    1983-01-01

    absent, but on balance the airlift effort was managed and executed intelligently. Probably the most serious failing was the Air Force’s tardiness in...Clark Air Base, Philippines receives a red cross; Maj. James E. Marrott at the controls of the first C-141 flown into Hanoi; a jubilant ex-POW deplanes...parachutes and rigging for airdrops.t Surface and air shipments from the United States similarly converged at the Philippines . * The unit was first

  6. Makers of the United States Air Force,

    Science.gov (United States)

    1987-01-01

    gratitude and thanks to the Aerospace Educational Foun- dation for its strong support and major financial contribution toward the successful research...several times when the Air Force-and its predecessors-was rescued from financial or organizational 2 INTRODUCTION: MEN WITH A MISSION doldrums by a poor...job included a willingness to keep a skeptical eye on the shenanigans of Assistant Chief of Air Service Billy Mitchell and other air zealots. Knerr

  7. Approaches to the design of clean air handling facilities for radiopharmaceuticals

    International Nuclear Information System (INIS)

    2000-01-01

    Manufacturing, handling and administering processes of radiopharmaceuticals have to meet the requirements of both the fields viz. ''radio'' activity and ''pharma'' activity. Both these fields often dictate conflicting requirements. A step by step analysis of these conflicts can lead to practices reasonably acceptable to both the fields. The design approaches include engineering concepts of radiation protection, concepts and practices for pharmaceuticals, biologically unsafe products/processes and manufacturing, handling and administering processes of radiopharmaceuticals

  8. Microbiological burden in air culture at various units of a tertiary care government hospital in Nepal

    Directory of Open Access Journals (Sweden)

    Binaya Sapkota

    2016-01-01

    Full Text Available Background The environmental matrices (water, air, and surfaces play a vital role as reservoirs of Legionella spp. and Pseudomonas aeruginosa (Pseudomonas spp.. Hence, hospital environment control procedures are effective measures for reducing nosocomial infections. Aims This study was carried out to explore the profiles of microorganisms in air culture at various wards/units of a tertiary care hospital in Nepal. Methods A descriptive cross-sectional study was carried out at various wards/units of a tertiary care hospital in Nepal between January and September 2015 to explore the microbiological burden in inanimate objects. Each week one ward or unit was selected for the study. Bed, tap, the entire room, trolley, computer, phone, rack handles, table, chair, door, stethoscope, oxygen mask, gown, cupboard handles, and wash basins were selected for air culture testing. Ten different wards/units and 77 locations/pieces of equipment were selected for air culture by employing a simple random sampling technique. Information about the organisms was entered into the Statistical Package for the Social Sciences (SPSS Version 22 (IBM: Armonk, NY and descriptive analyses were carried out. Results Staphylococcus aureus (S. aureus, Micrococcus, coagulase negative staphylococcus (CONS, Bacillus, Pseudomonas aeruginosa, yeast, and Acinetobacter were the most commonly detected organisms. In the postoperative ward, S. aureus was the most frequently detected microorganism. Micrococcus was detected in four out of 10 locations. In the x-ray unit, S. aureus was detected in three out of four locations. Conclusion S. aureus, Micrococcus, CONS, Bacillus, Pseudomonas, yeast, and Acinetobacter were the most common organisms detected.

  9. United States Air Force Nurse Crops Captains' Perceived Leadership Effectiveness

    National Research Council Canada - National Science Library

    Randall, Marjorie

    1998-01-01

    ... effectiveness of nurses who lacked the additional training. Two hundred and seventy-nine United States Air Force Nurse Corps Captains with management experience completed Kouzes and Posner's Leadership Practice Inventory-Self (LPI...

  10. United States Air Force Nurse Crops Captains' Perceived Leadership Effectiveness

    National Research Council Canada - National Science Library

    Randall, Marjorie

    1998-01-01

    The purpose of this study was to examine perceived leadership effectiveness of nurses who attended the United States Air Force Nursing Service Management residence course with the perceived leadership...

  11. A Survey of Rabbit Handling Methods Within the United Kingdom and the Republic of Ireland.

    Science.gov (United States)

    Oxley, James Andrew; Ellis, Clare Frances; McBride, E Anne; McCormick, Wanda Denise

    2018-04-25

    Rabbits are commonly kept in a variety of settings, including homes, laboratories, and veterinary clinics. Despite the popularity of keeping this prey species, little research has investigated current methods of handling. The aim of this study was to examine the experience of caregivers (owners and keepers) in using five handling methods commonly referred to in books written for companion animal (pet) owners and veterinary and/or laboratory personnel. An online survey was completed by 2644 respondents, representing all three of these groups, and breeders. Data were acquired to determine sources that participants used to gain knowledge of different handling methods, the methods they used and for what purposes they used them, and their perceptions of any associated difficulties or welfare concerns. Results indicated that participants most frequently used the method of supporting a rabbit's body against a person's chest, which was considered the easiest and most welfare-friendly method of the handling methods explored. "Scruffing with rear support" was the least used method and was considered to be distressing and painful for the rabbit. As rabbits are a terrestrial prey species, being picked up is likely an innately stressful experience. Additional research is encouraged to explore the experience of rabbits during handling to identify methods that can be easily used with the fewest welfare compromises.

  12. Laws and legal safeguards governing the handling of air pollution in ...

    African Journals Online (AJOL)

    Air pollution is one of the most important aspect of environmental degradation and one of the problems of large industrial cities, which, in addition to imposing costs on society, endanger the health of present and future generations, strongly. Air pollution leaves harmful effects on human and natural environment at three ...

  13. Impact of hazardous waste handling legislation on nuclear installations and radioactive waste management in the United States

    International Nuclear Information System (INIS)

    Trosten, L.M.

    1988-01-01

    The United States has enacted complex legislation to help assure proper handling of hazardous waste and the availability of funds to cover the expenditures. There are a number of uncertainties concerning the impact of this legislation, and regulations promulgated by the Environmental Protection Agency and the states, upon nuclear installations and radioactive waste management. This report provides an overview of the U.S. hazardous waste legislation and examines the outlook for its application to the nuclear industry (NEA) [fr

  14. Prototype unit for the air decontamination

    International Nuclear Information System (INIS)

    Garcia A, J.

    1991-01-01

    In this work it has the objective of to design and to manufacture an unit that took advantage of the filters of national production in appropriate form, and to offer a wide protection to the maintenance personnel that carries out the replacement, besides to be able to be installed in any position and to facilitate the adsorber installation

  15. The relationship between manual handling performance and recent flying experience in air transport pilots.

    Science.gov (United States)

    Ebbatson, Matt; Harris, Don; Huddlestone, John; Sears, Rodney

    2010-02-01

    Modern jet transport aircraft are typically flown using the on-board automation by the pilot programming commands into the auto-flight systems. Anecdotal evidence exists suggesting that pilots of highly automated aircraft experience manual flying skills decay as a result of a lack of opportunity to practise hand-flying during line operations. The ability of a pilot to revert to basic manual control is essential, for example, in cases where the aircraft's automatic capability is diminished or when reconfiguring the automatics is an ineffective use of crew capacity. However, there is a paucity of objective data to substantiate this perceived threat to flight safety. Furthermore, traditional performance measurement techniques may lack the ability to identify subtle but significant differences in pilots' manual handling ability in large transport aircraft. This study examines the relationship between pilot manual handling performance and their recent flying experience using both traditional flight path tracking measures and frequency-based control strategy measures. Significant relationships are identified between pilots' very recent flying experience and their manual control strategy. Statement of Relevance: The study demonstrates a novel application of frequency analysis, which produces a broader and more sensitive analysis of pilot performance than has been offered in previous research. Additionally, the relationships that are found to exist between recent flying experience and manual flying performance will help to guide future pilot assessment and training.

  16. AIRS/Aqua Level 3 Pentad quantization in physical units (AIRS+AMSU) V005

    Data.gov (United States)

    National Aeronautics and Space Administration — AIRS/Aqua Level 3 pentad quantization product in physical units (Without HSB). The geophysical parameters have been averaged and binned into 1 x 1 deg grid cells,...

  17. Aqua AIRS Level 3 Quantization in Physical Units (AIRS+AMSU) V006

    Data.gov (United States)

    National Aeronautics and Space Administration — AIRS/Aqua Level 3 monthly quantization product in physical units (Without HSB). The quantization products (QP) are distributional summaries derived from the Level-2...

  18. AIRS/Aqua Level 3 Pentad quantization in physical units (AIRS+AMSU+HSB) V005

    Data.gov (United States)

    National Aeronautics and Space Administration — AIRS/Aqua Level 3 pentad quantization product in physical units (With HSB). The quantization products (QP) are distributional summaries derived from the Level-2...

  19. Increasing EDV Range through Intelligent Cabin Air Handling Strategies: Annual Progress Report

    Energy Technology Data Exchange (ETDEWEB)

    Leighton, Daniel [National Renewable Energy Lab. (NREL), Golden, CO (United States); Rugh, John [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-08-01

    Computational fluid dynamics (CFD) simulations of a Ford Focus Electric demonstrated that a split flow heating, ventilating and air conditioning (HVAC) system with rear recirculation ducts can reduce cabin heating loads by up to 57.4% relative to full fresh air usage under some conditions (steady state, four passengers, ambient temperature of -5 deg C). Simulations also showed that implementing a continuous recirculation fraction control system into the original equipment manufacturer (OEM) HVAC system can reduce cabin heating loads by up to 50.0% relative to full fresh air usage under some conditions (steady state, four passengers, ambient temperature of -5 deg C). Identified that continuous fractional recirculation control of the OEM system can provide significant energy savings for EVs at minimal additional cost, while a split flow HVAC system with rear recirculation ducts only provides minimal additional improvement at significant additional cost.

  20. Application of the air/water cushion technology for handling of heavy waste packages in Sweden and France

    International Nuclear Information System (INIS)

    Bosgiraud, Jean-Michel; Seidler, Wolf K.; Londe, Louis; Thurner, Erik; Pettersson, Stig

    2008-01-01

    The disposal of certain types of radioactive waste canisters in a deep repository involves handling and emplacement of very heavy loads. The weight of these particular canisters can be in the order of 20 to 50 metric tons. They generally have to be handled underground in openings that are not much larger than the canisters themselves as it is time consuming and expensive to excavate and backfill large openings in a repository. This therefore calls for the development of special technology that can meet the requirements for safe operation in an industrial scale in restrained operating spaces. Air/water cushion lifting systems are used world wide in the industry for moving heavy loads. However, until now the technology needed for emplacing heavy cylindrical radioactive waste packages in bored drifts (with narrow annular gaps) has not been developed or demonstrated previously. This paper describes the related R and D work carried out by ANDRA (for air cushion technology) and by SKB and Posiva (for water cushion technology) respectively, mainly within the framework of the European Commission (EC) funded Integrated Project called ESDRED (6th European Framework Programme). The background for both the air and the water cushion applications is presented. The specific characteristics of the two different emplacement concepts are also elaborated. The various phases of the Test Programmes (including the Prototype phases) are detailed and illustrated for the two lifting media. Conclusions are drawn for each system developed and evaluated. Finally, based on the R and D experience, improvements deemed necessary for an industrial application are listed. The tests performed so far have shown that the emplacement equipment developed is operating efficiently. However further tests are required to verify the availability and the reliability of the equipment over longer periods of time and to identify the modifications that would be needed for an industrial application in a nuclear

  1. HEAT ENGINEERING TESTING OF AIR COOLING UNIT OF HORIZONTAL TYPE

    OpenAIRE

    Rohachov, Valerii Andriiovych; Semeniako, Oleksandr Volodymyrovych; Лазоренко, Р. О.; Середа, Р. М.; Parafeinyk, Volodymyr Petrovych

    2018-01-01

    The results of the thermal tests of the section of air cooler, the heat-exchange surface of which is made up of chess package of bimetal finned tubes are presented. The methods of research are presented, the experimental stand is described, the measurement errors are given. The efficiency of the experimental stand and the accuracy of the experimental data on it are confirmed. Proposed to use the stand for researches of air cooling units with other types and sections of finned tubes.

  2. Atmospheric Pressure Corrections in Geodesy and Oceanography: a Strategy for Handling Air Tides

    Science.gov (United States)

    Ponte, Rui M.; Ray, Richard D.

    2003-01-01

    Global pressure data are often needed for processing or interpreting modern geodetic and oceanographic measurements. The most common source of these data is the analysis or reanalysis products of various meteorological centers. Tidal signals in these products can be problematic for several reasons, including potentially aliased sampling of the semidiurnal solar tide as well as the presence of various modeling or timing errors. Building on the work of Van den Dool and colleagues, we lay out a strategy for handling atmospheric tides in (re)analysis data. The procedure also offers a method to account for ocean loading corrections in satellite altimeter data that are consistent with standard ocean-tide corrections. The proposed strategy has immediate application to the on-going Jason-1 and GRACE satellite missions.

  3. Analysis of fuel handling system for fuel bundle safety during station blackout in 500 MWe PHWR unit of India

    Energy Technology Data Exchange (ETDEWEB)

    Madhuresh, R; Nagarajan, R; Jit, I; Sanatkumar, A [Nuclear Power Corporation of India Ltd., Mumbai (India)

    1997-12-31

    Situations of Station Blackout (SBO) i.e. postulated concurrent unavailability of Class Ill and Class IV power, could arise for a long period, while on-power refuelling or other fuel handling operations are in progress with the hot irradiated fuel bundles being anywhere in the system from the Reactor Building to the Spent Fuel Storage Bay. The cooling provisions for these fuel bundles are diverse and specific to the various stages of fuel handling operations and are either on Class Ill or on Class II power with particular requirements of instrument air. Therefore, during SBO, due to the limited availability of Class II power and instrument air, it becomes difficult to maintain cooling to these fuel bundles. However, some minimal cooling is essential, to ensure the safety of the bundles. As discussed in the paper, safety of these fuel bundles in the system and/or for those lying in the liner tube region of the reactor end fitting is ensured, during SBO, by resorting to passive means like `stay-put`, `gravity- fill`, `D{sub 2}0- steaming` etc. for cooling the bundles. The paper also describes various consequences emanating from these cooling schemes. (author). 6 refs., 2 tabs., 8 figs.

  4. Analysis of fuel handling system for fuel bundle safety during station blackout in 500 MWe PHWR unit of India

    International Nuclear Information System (INIS)

    Madhuresh, R.; Nagarajan, R.; Jit, I.; Sanatkumar, A.

    1996-01-01

    Situations of Station Blackout (SBO) i.e. postulated concurrent unavailability of Class Ill and Class IV power, could arise for a long period, while on-power refuelling or other fuel handling operations are in progress with the hot irradiated fuel bundles being anywhere in the system from the Reactor Building to the Spent Fuel Storage Bay. The cooling provisions for these fuel bundles are diverse and specific to the various stages of fuel handling operations and are either on Class Ill or on Class II power with particular requirements of instrument air. Therefore, during SBO, due to the limited availability of Class II power and instrument air, it becomes difficult to maintain cooling to these fuel bundles. However, some minimal cooling is essential, to ensure the safety of the bundles. As discussed in the paper, safety of these fuel bundles in the system and/or for those lying in the liner tube region of the reactor end fitting is ensured, during SBO, by resorting to passive means like 'stay-put', 'gravity- fill', 'D 2 0- steaming' etc. for cooling the bundles. The paper also describes various consequences emanating from these cooling schemes. (author). 6 refs., 2 tabs., 8 figs

  5. Handling of TRIGA spent fuel at the Medical University of Hanover and its return to the United States

    International Nuclear Information System (INIS)

    Hampel, Gabriele; Harke, Heinrich; Kelm, Wieland; Klaus, Uwe

    2008-01-01

    The Medical University of Hannover (MHH) was taking part in the US Department of Energy's (DOE) 'Research Reactor Spent Fuel Acceptance Program' to return its 76 spent TRIGA fuel elements to the United States in the middle of 1999. The fuel elements have been moved to the Idaho National Engineering and Environmental Laboratory (INEEL) in Idaho. This paper describes the technical facilities for handling the fuel elements at the MHH and the various steps in removing the fuel elements from the reactor, transferring them to the transport cask and shipping them to the INEEL. (authors)

  6. [Manual handling of loads in the hotel trade: the experience of the ASL (Local Health Unit) Milan].

    Science.gov (United States)

    Fontani, S; Mercuri, Irene; Salicco, R; Veratti, Silvia; Sorrentino, L

    2010-01-01

    There are over 400 hotels in Milan with a guest capacity of about 62,000 and employing more than 10,000 workers. In 2008/09 the Occupational Health and Safety Service of A.S.L. Milano (Local Health Unit) carried out research into the hotel trade to ascertain the development of this commercial sector, also in view of EXPO 2015. The aim of the project was to improve hygiene and safety conditions and carry out preventive measures. A specific purpose was to study manual handling of loads and repetitive movements risk. The study covered 30 hotels and 7 temporary staff cooperatives. We acquired the Risk Evaluation Document, the Health Surveillance Programme and Registers of Labour Accidents to analyze manual handling of loads and repetitive movements. In the investigations and assessments on hotels we used currently available scientific tools--NIOSH Lifting Index, Push and Pulling Analysis, OC.R.A. Check-List--to study risks related to handling loads and upper limb mechanical overload, which revealed a specific occupational risk that requires a fresh approach to prevention and safety in the entire sector. Chambermaid: LI (Range): 0.57-2.75; Push and Pulling Actions: Fi 0.66-Fm 1.5 and Fi 0.76-Fm 1.33 respectively; OC.R.A. Check-List: 21. Porter: LI (Range): 0.77-3.75. Maintenance staff LI (Range): 0.57-2.75. The study highlighted the presence of risk due to manual handling of loads and repetitive movements in porters, maintenance personnel and particularly in chambermaids that up to now have been poorly assessed by safety experts. Analysis of the information contained in the registers of labour accidents suggests that a significant number of accidents can be related to muscular-skeletal disorders that affect especially cleaning, portering and kitchen staff

  7. Information Assurance within the United States Air Force

    Science.gov (United States)

    Cherry, John D.

    2010-01-01

    According to the Department of Defense (DoD), a review of information assurance (IA) in the United States Air Force (USAF) in 2009, cyber security is jeopardized because of information loss. This situation has occurred in large part because of less than optimal training practices or adherence to training protocols. The purpose of this study was…

  8. Radioactive air emissions notice of construction portable temporary radioactive air emission units - August 1998; FINAL

    International Nuclear Information System (INIS)

    FRITZ, D.W.

    1999-01-01

    This notice of construction (NOC) requests a categorical approval for construction and operation of three types of portable/temporary radionuclide airborne emission units (PTRAEUs). These three types are portable ventilation-filter systems (Type I), mobile sample preparation facilities (Type II), and mobile sample screening and analysis facilities (Type 111). Approval of the NOC application is intended to allow construction and operation of the three types of PTRAEUs without prior project-specific approval. Environmental cleanup efforts on the Hanford Site often require the use of PTRAEUs. The PTRAEUs support site characterization activities, expedited response actions (ERAs), sampling and monitoring activities, and other routine activities. The PTRAEUs operate at various locations around the Hanford Site. Radiation Air Emissions Program, Washington Administrative Code (WAC) 246-247, requires that the Washington State Department of Health (WDOH) be notified before construction of any new emission that would release airborne radioactivity. The WDOH also must receive notification before any modification of an existing source. This includes changes in the source term or replacement of emission control equipment that might significantly contribute to the offsite maximum dose from a licensed facility. During site characterization activities, ERAs, sampling and monitoring activities, and other routine activities, the PTRAEUs might require startup immediately. The notification period hampers efforts to complete such activities in an effective and timely manner. Additionally, notification is to be submitted to the WDOH when the PTRAEUs are turned off. The U.S. Department of Energy, Richland Operations Office (DOE-RL) potentially could generate several notifications monthly. The WDOH would be required to review and provide approval on each NOC as well as review the notices of discontinued sources. The WDOH regulation also allows facilities the opportunity to request a

  9. Eielson Air Force Base Operable Unit 2 baseline risk assessment

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, R.E.; Jarvis, T.T.; Jarvis, M.R.; Whelan, G.

    1994-10-01

    Operable Unit 2 at Eielson Air Force Base (AFB) near Fairbanks, is one of several operable units characterized by petroleum, oil, and lubricant contamination, and by the presence of organic products floating at the water table, as a result of Air Force operations since the 1940s. The base is approximately 19,270 acres in size, and comprises the areas for military operations and a residential neighborhood for military dependents. Within Operable Unit 2, there are seven source areas. These source areas were grouped together primarily because of the contaminants released and hence are not necessarily in geographical proximity. Source area ST10 includes a surface water body (Hardfill Lake) next to a fuel spill area. The primary constituents of concern for human health include benzene, toluene, ethylbenzene, and xylenes (BTEX). Monitored data showed these volatile constituents to be present in groundwater wells. The data also showed an elevated level of trace metals in groundwater.

  10. Short-term effects of air pollution on lower respiratory diseases and forecasting by the group method of data handling

    Science.gov (United States)

    Zhu, Wenjin; Wang, Jianzhou; Zhang, Wenyu; Sun, Donghuai

    2012-05-01

    Risk of lower respiratory diseases was significantly correlated with levels of monthly average concentration of SO2; NO2 and association rules have high lifts. In view of Lanzhou's special geographical location, taking into account the impact of different seasons, especially for the winter, the relations between air pollutants and the respiratory disease deserve further study. In this study the monthly average concentration of SO2, NO2, PM10 and the monthly number of people who in hospital because of lower respiratory disease from January 2001 to December 2005 are grouped equidistant and considered as the terms of transactions. Then based on the relational algebraic theory we employed the optimization relation association rule to mine the association rules of the transactions. Based on the association rules revealing the effects of air pollutants on the lower respiratory disease, we forecast the number of person who suffered from lower respiratory disease by the group method of data handling (GMDH) to reveal the risk and give a consultation to the hospital in Xigu District, the most seriously polluted district in Lanzhou. The data and analysis indicate that individuals may be susceptible to the short-term effects of pollution and thus suffer from lower respiratory diseases and this effect presents seasonal.

  11. China's international trade and air pollution in the United States.

    Science.gov (United States)

    Lin, Jintai; Pan, Da; Davis, Steven J; Zhang, Qiang; He, Kebin; Wang, Can; Streets, David G; Wuebbles, Donald J; Guan, Dabo

    2014-02-04

    China is the world's largest emitter of anthropogenic air pollutants, and measurable amounts of Chinese pollution are transported via the atmosphere to other countries, including the United States. However, a large fraction of Chinese emissions is due to manufacture of goods for foreign consumption. Here, we analyze the impacts of trade-related Chinese air pollutant emissions on the global atmospheric environment, linking an economic-emission analysis and atmospheric chemical transport modeling. We find that in 2006, 36% of anthropogenic sulfur dioxide, 27% of nitrogen oxides, 22% of carbon monoxide, and 17% of black carbon emitted in China were associated with production of goods for export. For each of these pollutants, about 21% of export-related Chinese emissions were attributed to China-to-US export. Atmospheric modeling shows that transport of the export-related Chinese pollution contributed 3-10% of annual mean surface sulfate concentrations and 0.5-1.5% of ozone over the western United States in 2006. This Chinese pollution also resulted in one extra day or more of noncompliance with the US ozone standard in 2006 over the Los Angeles area and many regions in the eastern United States. On a daily basis, the export-related Chinese pollution contributed, at a maximum, 12-24% of sulfate concentrations over the western United States. As the United States outsourced manufacturing to China, sulfate pollution in 2006 increased in the western United States but decreased in the eastern United States, reflecting the competing effect between enhanced transport of Chinese pollution and reduced US emissions. Our findings are relevant to international efforts to reduce transboundary air pollution.

  12. The presence and partitioning behavior of flame retardants in waste, leachate, and air particles from Norwegian waste-handling facilities

    Institute of Scientific and Technical Information of China (English)

    Nicolas A.O.Morin; Patrik L.Andersson; Sarah E.Hale; Hans Peter H.Arp

    2017-01-01

    Flame retardants in commercial products eventually make their way into the waste stream.Herein the presence of flame retardants in Norwegian landfills,incineration facilities and recycling sorting/defragmenting facilities is investigated.These facilities handled waste electrical and electronic equipment (WEEE),vehicles,digestate,glass,combustibles,bottom ash and fly ash.The flame retardants considered included polybrominated diphenyl ethers (∑BDE-10) as well as dechlorane plus,polybrominated biphenyls,hexabromobenzene,pentabromotoluene and pentabromoethylbenzene (collectively referred to as ∑FR-7).Plastic,WEEE and vehicles contained the largest amount of flame retardants (∑BDE-10:45,000-210,000 μg/kg;∑FR-7:300-13,000 μg/kg).It was hypothesized leachate and air concentrations from facilities that sort/defragment WEEE and vehicles would be the highest.This was supported for total air phase concenttations (∑BDE-10:9000-195,000 pg/m3 WEEE/vehicle facilities,80-900 pg/m3 in incineration/sorting and landfill sites),but not for water leachate concentrations (e.g.,ΣBDE-10:15-3500 ng/L in WEEE/Vehicle facilities and 1-250 ng/L in landfill sites).Landfill leachate exhibited similar concentrations as WEEE/vehicle sorting and defragmenting facility leachate.To better account for concentrations in leachates at the different facilities,waste-water partitioning coefficients,Kwaste were measured (for the first time to our knowledge for flame retardants).WEEE and plastic waste had elevated Kwaste compared to other wastes,likely because flame retardants are directly added to these materials.The results of this study have implications for the development of strategies to reduce exposure and environmental emissions of flame retardants in waste and recycled products through improved waste management practices.

  13. The presence and partitioning behavior of flame retardants in waste, leachate, and air particles from Norwegian waste-handling facilities.

    Science.gov (United States)

    Morin, Nicolas A O; Andersson, Patrik L; Hale, Sarah E; Arp, Hans Peter H

    2017-12-01

    Flame retardants in commercial products eventually make their way into the waste stream. Herein the presence of flame retardants in Norwegian landfills, incineration facilities and recycling sorting/defragmenting facilities is investigated. These facilities handled waste electrical and electronic equipment (WEEE), vehicles, digestate, glass, combustibles, bottom ash and fly ash. The flame retardants considered included polybrominated diphenyl ethers (∑BDE-10) as well as dechlorane plus, polybrominated biphenyls, hexabromobenzene, pentabromotoluene and pentabromoethylbenzene (collectively referred to as ∑FR-7). Plastic, WEEE and vehicles contained the largest amount of flame retardants (∑BDE-10: 45,000-210,000μg/kg; ∑FR-7: 300-13,000μg/kg). It was hypothesized leachate and air concentrations from facilities that sort/defragment WEEE and vehicles would be the highest. This was supported for total air phase concentrations (∑BDE-10: 9000-195,000pg/m 3 WEEE/vehicle facilities, 80-900pg/m 3 in incineration/sorting and landfill sites), but not for water leachate concentrations (e.g., ∑BDE-10: 15-3500ng/L in WEEE/Vehicle facilities and 1-250ng/L in landfill sites). Landfill leachate exhibited similar concentrations as WEEE/vehicle sorting and defragmenting facility leachate. To better account for concentrations in leachates at the different facilities, waste-water partitioning coefficients, K waste were measured (for the first time to our knowledge for flame retardants). WEEE and plastic waste had elevated K waste compared to other wastes, likely because flame retardants are directly added to these materials. The results of this study have implications for the development of strategies to reduce exposure and environmental emissions of flame retardants in waste and recycled products through improved waste management practices. Copyright © 2017. Published by Elsevier B.V.

  14. An alpha particle detector based on a GPS mosaic scintillator plate for continuous air monitoring in plutonium handling facilities

    International Nuclear Information System (INIS)

    Kaneko, Junichi H.; Izaki, Kenji; Toui, Kouhei; Shimaoka, Takehiro; Morishita, Yuki; Tsubota, Youichi; Higuchi, Mikio

    2016-01-01

    An alpha particle detector was developed for continuous air monitoring of radioactive contamination in working chambers at plutonium handling facilities. A 5-cm-square Gd 2 Si 2 O 7 :Ce (cerium-doped gadolinium pyro-silicate, GPS:Ce) mosaic scintillator plate for alpha particle measurements was fabricated from GPS single-crystal grains of around 550 μm diameter; the GPS grains were made of a GPS polycrystalline body grown using a top seeded solution method. The scintillator layer thickness was approximately 100 μm. The surface filling rate of the GPS grains was ca. 62%. To suppress the influence of non-uniformity of pulse heights of a photomultiplier tube, a central part of ∅ 40 mm of a 76-mm-diameter photomultiplier tube was used. In addition, 3 mm thick high-transmission glass was used as a substrate of the scintillator plate. The detector achieved energy resolution of 13% for 5.5 MeV alpha particles, detection efficiency of 61% and a radon progeny nuclide reduction ratio of 64.5%. A new alpha particle detector was developed to achieve a high radon progeny nuclide reduction ratio approaching that of a silicon semiconductor detector, with high resistance to electromagnetic noise and corrosion. - Highlights: • An alpha particle detector was developed for continuous air monitoring. • The detector comprises a mosaic scintillator plate and a photomultiplier tube. • A 5-cm-square GPS mosaic scintillator plate was fabricated. • Its respective energy resolution and detection efficiency were 13 and 61%. • The radon progeny nuclide reduction ratio of the developed detector was 64.5%.

  15. Dry coolers and air-condensing units (Review)

    Science.gov (United States)

    Milman, O. O.; Anan'ev, P. A.

    2016-03-01

    The analysis of factors affecting the growth of shortage of freshwater is performed. The state and dynamics of the global market of dry coolers used at electric power plants are investigated. Substantial increase in number and maximum capacity of air-cooled condensers, which have been put into operation in the world in recent years, are noted. The key reasons facilitating the choice of developers of the dry coolers, in particular the independence of the location of thermal power plant from water sources, are enumerated. The main steam turbine heat removal schemes using air cooling are considered, their comparison of thermal efficiency is assessed, and the change of three important parameters, such as surface area of heat transfer, condensate pump flow, and pressure losses in the steam exhaust system, are estimated. It is shown that the most effective is the scheme of direct steam condensation in the heat-exchange tubes, but other schemes also have certain advantages. The air-cooling efficiency may be enhanced much more by using an air-cooling hybrid system: a combination of dry and wet cooling. The basic applied constructive solutions are shown: the arrangement of heat-exchange modules and the types of fans. The optimal mounting design of a fully shopassembled cooling system for heat-exchange modules is represented. Different types of heat-exchange tubes ribbing that take into account the operational features of cooling systems are shown. Heat transfer coefficients of the plants from different manufacturers are compared, and the main reasons for its decline are named. When using evaporative air cooling, it is possible to improve the efficiency of air-cooling units. The factors affecting the faultless performance of dry coolers (DC) and air-condensing units (ACU) and the ways of their elimination are described. A high velocity wind forcing reduces the efficiency of cooling systems and creates preconditions for the development of wind-driven devices. It is noted that

  16. Involvement of the ORNL Chemical Technology Division in contaminated air and water handling at the Three Mile Island Nuclear Power Station

    International Nuclear Information System (INIS)

    Brooksbank, R.E.; King, L.J.

    1979-08-01

    The President's Commission on the Accident at Three Mile Island requested that Oak Ridge National Laboratory (ORNL) generate documents concerning two areas in which ORNL personnel provided on-site assistance following the accident on March 28, 1979. These are: instrumentation diagnostics, and the treatment of radioactive wastes and liquid effluents stemming from the accident. This report describes the involvement of the ORNL Chemical Technology Division (CTD) in contaminated air and water handling at Three Mile Island

  17. Handling Pyrophoric Reagents

    Energy Technology Data Exchange (ETDEWEB)

    Alnajjar, Mikhail S.; Haynie, Todd O.

    2009-08-14

    Pyrophoric reagents are extremely hazardous. Special handling techniques are required to prevent contact with air and the resulting fire. This document provides several methods for working with pyrophoric reagents outside of an inert atmosphere.

  18. 76 FR 82323 - Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units

    Science.gov (United States)

    2011-12-30

    ... Filtration and Adsorption Units AGENCY: Nuclear Regulatory Commission. ACTION: Draft regulatory guide... for Air Filtration and Adsorption Units of Postaccident Engineered-Safety-Feature Atmosphere Cleanup... testing of air filtration and iodine adsorption units of engineered-safety-feature (ESF) atmosphere...

  19. Environmental Assessment for the National Museum of the United States Air Force Addition, Wright-Patterson Air Force Base, Ohio

    Science.gov (United States)

    2013-02-01

    AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) United States Air Force 88th...Air Base Wing Wright-Patterson Air Force Base, Ohio 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES...visitors nationwide and from foreign countries. Softball and soccer fields are located adjacent to the Museum grounds and are operated by the 88 Air

  20. Chemotherapy drug handling in first opinion small animal veterinary practices in the United Kingdom: results of a questionnaire survey.

    Science.gov (United States)

    Edery, E G

    2017-05-27

    To investigate how first opinion small animal veterinary surgeons in the UK handled chemotherapeutic agents, a questionnaire was distributed at the 2014 British Small Animal Veterinary Association congress and by internet. Chemotherapy was regularly offered by 70.4 per cent of the respondents. Gold standards defined according to available guidelines for safe handling of antineoplastic drugs were poorly followed by general practitioners with only 2 per cent of respondents complying with all of them. Dedicated facilities for preparation and administration of cytotoxic drugs were variably available among participants. The level of training of staff indirectly involved in handling chemotherapy was appropriate in less than 50 per cent of practices. No association was found between demographic characteristics of the sampled population and the decision to perform chemotherapy. The results of this study raise concerns about the safety of the veterinary staff in first opinion practices involved in handling chemotherapy. British Veterinary Association.

  1. Effect of mobile unidirectional air flow unit on microbial contamination of air in standard urologic procedures.

    Science.gov (United States)

    Ferretti, Stefania; Pasquarella, Cesira; Fornia, Samanta; Saccani, Elisa; Signorelli, Carlo; Vitali, Pietro; Sansebastiano, Giuliano Ezio

    2009-12-01

    Infection is one of the most feared complications of surgery. New instrumentation is being developed to reduce deposition of bacteria. We investigated 45 major surgical procedures (21 radical nephrectomies [RN] and 24 radical retropubic prostatectomies [RRP]) in our urology department during 2007. In about one-half of the interventions, an ultraclean air flow mobile (UAF) unit was used. Bacterial sedimentation was evaluated by nitrocellulose membranes placed on the instrument tray and by settle plates positioned at four points in the operating room. In 27 operations, an additional membrane was located near the incision. Bacterial counts on the nitrocellulose membranes during RN were 230 colony-forming units (cfu)/m(2)/h with the UAF unit and 2,254 cfu/m(2)/h without the unit (p = 0.001). During RRP, the values were 288 cfu/m(2)/h and 3,126 cfu/m(2)/h respectively (p = 0.001). The membrane placed near the incision during RN showed a microbial count of 1,235 cfu/m(2)/h with the UAF unit and 5,093 cfu/m(2)/h without the unit (p = 0.002); during RRP, the values were 1,845 cfu/m(2)/h and 3,790 cfu/m(2)/h, respectively (difference not significant). Bacterial contamination detected by settle plates during RN showed a mean value of 2,273 cfu/m(2)/h when the UAF unit was used and 2,054 cfu/m(2)/h without the unit; during RRP, the values were 2,332 cfu/m(2)/h and 2,629 cfu/m(2)/h with and without the UAF unit, respectively (NS). No statistically significant differences were detected in the clinical data registered in patients operated on under standard conditions and while the UAF unit was functioning. The UAF appears able to reduce microbial contamination at the operating table, reaching a bacterial number obtained in ultraclean operating theatres.

  2. Experimental analysis of an air-to-air heat recovery unit for balanced ventilation systems in residential buildings

    International Nuclear Information System (INIS)

    Fernandez-Seara, Jose; Diz, Ruben; Uhia, Francisco J.; Dopazo, Alberto; Ferro, Jose M.

    2011-01-01

    This paper deals with the experimental analysis of an air-to-air heat recovery unit equipped with a sensible polymer plate heat exchanger (PHE) for balanced ventilation systems in residential buildings. The PHE is arranged in parallel triangular ducts. An experimental facility was designed to reproduce the typical outdoor and exhaust air conditions with regard to temperature and humidity. The unit was tested under balanced operation conditions, as commonly used in practice. A set of tests was conducted under the reference operating conditions to evaluate the PHE performance. Afterwards, an experimental parametric analysis was conducted to investigate the influence of changing the operating conditions on the PHE performance. Experiments were carried out varying the inlet fresh air temperature, the exhaust air relative humidity and the air flow rate. The experimental results are shown and discussed in this paper.

  3. Ergonomics and patient handling.

    Science.gov (United States)

    McCoskey, Kelsey L

    2007-11-01

    This study aimed to describe patient-handling demands in inpatient units during a 24-hour period at a military health care facility. A 1-day total population survey described the diverse nature and impact of patient-handling tasks relative to a variety of nursing care units, patient characteristics, and transfer equipment. Productivity baselines were established based on patient dependency, physical exertion, type of transfer, and time spent performing the transfer. Descriptions of the physiological effect of transfers on staff based on patient, transfer, and staff characteristics were developed. Nursing staff response to surveys demonstrated how patient-handling demands are impacted by the staff's physical exertion and level of patient dependency. The findings of this study describe the types of transfers occurring in these inpatient units and the physical exertion and time requirements for these transfers. This description may guide selection of the most appropriate and cost-effective patient-handling equipment required for specific units and patients.

  4. Evaluation of a prototype air transport system for use in a crate handling and size reduction facility

    International Nuclear Information System (INIS)

    Kennedy, S.T.

    1987-01-01

    This paper describes in detail the design features and evaluation, under simulated active conditions, of a purpose designed remotely operated air transporter system. The paper concludes by recommending that an air transporter, based on this concept, is considered for the alpha active facility. (author)

  5. Evaluation of a prototype air transport system for use in a crate handling and size reduction facility

    International Nuclear Information System (INIS)

    Kennedy, S.T.

    1987-09-01

    This paper describes the design features and evaluation, under simulated active conditions, of a purpose designed remotely operated air transporter system. The paper concludes by recommending that an air transporter, based on this concept, is considered for the alpha active facility. (author)

  6. Handle with care

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1965-03-15

    Full text: A film dealing with transport of radioactive materials by everyday means - rail, road, sea and air transport - has been made for IAEA. It illustrates in broad terms some of the simple precautions which should be followed by persons dealing with such materials during shipment. Throughout, the picture stresses the transport regulations drawn up and recommended by the Agency, and in particular the need to carry out carefully the instructions based on these regulations in order to ensure that there is no hazard to the public nor to those who handle radioactive materials in transit and storage. In straightforward language, the film addresses the porter of a goods wagon, an airline cargo clerk, a dockside crane operator, a truck driver and others who load and ship freight. It shows the various types of package used to contain different categories of radioactive substances according to the intensity of the radiation emitted. It also illustrates their robustness by a series of tests involving drops, fires, impact, crushing, etc. Clear instructions are conveyed on what to do in the event of an unlikely accident with any type of package. The film is entitled, 'The Safe Transport of Radioactive Materials', and is No. 3 in the series entitled, 'Handle with Care'. It was made for IAEA through the United Kingdom Atomic Energy Authority by the Film Producers' Guild in the United Kingdom. It is in 16 mm colour, optical sound, with a running time of 20 minutes. It is available for order at $50 either direct from IAEA or through any of its Member Governments. Prints can be supplied in English, French, Russian or Spanish. Copies are also available for adaptation for commentaries in other languages. (author)

  7. 77 FR 38857 - Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units of Normal...

    Science.gov (United States)

    2012-06-29

    ... Filtration and Adsorption Units of Normal Atmosphere Cleanup Systems in Light-Water- Cooled Nuclear Power... Criteria for Air Filtration and Adsorption Units of Normal Atmosphere Cleanup Systems in Light-Water-Cooled... draft regulatory guide (DG), DG-1280, ``Design, Inspection, and Testing Criteria for Air Filtration and...

  8. Cooling energy efficiency and classroom air environment of a school building operated by the heat recovery air conditioning unit

    International Nuclear Information System (INIS)

    Wang, Yang; Zhao, Fu-Yun; Kuckelkorn, Jens; Liu, Di; Liu, Li-Qun; Pan, Xiao-Chuan

    2014-01-01

    The recently-built school buildings have adopted novel heat recovery ventilator and air conditioning system. Heat recovery efficiency of the heat recovery facility and energy conservation ratio of the air conditioning unit were analytically modeled, taking the ventilation networks into account. Following that, school classroom displacement ventilation and its thermal stratification and indoor air quality indicated by the CO 2 concentration have been numerically modeled concerning the effects of delivering ventilation flow rate and supplying air temperature. Numerical results indicate that the promotion of mechanical ventilation rate can simultaneously boost the dilution of indoor air pollutants and the non-uniformity of indoor thermal and pollutant distributions. Subsequent energy performance analysis demonstrates that classroom energy demands for ventilation and cooling could be reduced with the promotion of heat recovery efficiency of the ventilation facility, and the energy conservation ratio of the air conditioning unit decreases with the increasing temperatures of supplying air. Fitting correlations of heat recovery ventilation and cooling energy conservation have been presented. - Highlights: • Low energy school buildings and classroom environment. • Heat recovery facility operating with an air conditioning unit. • Displacement ventilation influenced by the heat recovery efficiency. • Energy conservation of cooling and ventilation through heat recovery. • Enhancement of classroom environment with reduction of school building energy

  9. The Role of United States Air Power in Peacekeeping

    National Research Council Canada - National Science Library

    Bash, Brooks

    1994-01-01

    .... Recognizing this trend and the fact that peacekeeping can serve US national security interests, US policymakers have earmarked military peacekeeping involvement, the employment of air power will...

  10. Handling of natural occurring radioactive deposits in the oil and gas industry in Norway, United Kingdom and the Netherlands

    International Nuclear Information System (INIS)

    Lysebo, I.; Tufto, P.

    1999-03-01

    Deposits containing naturally occurring radioactive materials is an increasing problem in oil and gas production. Laws and regulations in this area is under preparation, and it is a wish for harmonization with the other oil and gas producing countries in the North Sea. The report gives an overview of amounts of waste and activity levels, decontamination methods and waste handling in Norway, Great Britain and the Netherlands

  11. Network planning for scheduling operations in air cargo handling : a tool in medium term goods flow control

    NARCIS (Netherlands)

    Verwijmeren, M.A.A.P.; Tilanus, C.B.

    1993-01-01

    In the hub of a hub-and-spokes network for airfreight transportation, the main part of the incoming and outgoing goodsflow is in special loading units for airfreight. These loading units are metal pallets and containers up to eighteen cubic meters in size. The key part of operations in the hub is

  12. Integrated Unit Deployments: Rethinking Air National Guard Fighter Mobilizations

    Science.gov (United States)

    2016-06-01

    participation in the homeland defense mission. But they emphasized that homeland defense would not become an exclusive ANG mission. Operation...station that can absorb pilots and maintainers left behind. Few Air National Guard squadrons enjoy this luxury . Only Air Guard squadrons that are part

  13. Microbial contamination of dental unit waterlines and effect on quality of indoor air.

    Science.gov (United States)

    Kadaifciler, Duygu Göksay; Cotuk, Aysin

    2014-06-01

    The microbiological quality in dental unit waterlines (DUWLs) is considered to be important because patients and dental staff with suppressed immune systems are regularly exposed to water and aerosols generated from dental units (DUs). Opportunistic pathogens like Pseudomonas, Legionella, Candida, and Aspergillus can be present in DUWLs, while during consultations, bioaerosols can be dispersed in the air, thus resulting in effects on microbiological quality of indoor air. This present study represents microbiological air and water quality in dental offices (DOs) and also concerns the relationship between the quality of DO air and dental unit water. This study aimed to assess both the microbial quality of dental unit water and the indoor air in 20 DOs and to survey the effect on the quality of the indoor air with the existing microorganisms in dental unit water. Fourteen out of 20 (70 %) DUWLs were found to be contaminated with a high number of aerobic mesophilic heterotrophic bacteria. In terms of bacterial air contamination levels, in 90 % of DOs, a medium level (contamination was determined, while in terms of microfungal air contamination, in all DOs, a low level (contamination was determined. Potential infection or allergen agents, such as Pseudomonas, Micrococcus, Staphylococcus, Alternaria, Cladosporium, Penicillium, Aspergillus, and Paecilomyces were isolated from water and air samples. This study's determination of contamination sources and evaluation of microbial load in DOs could contribute to the development of quality control methods in the future.

  14. An Examination of the United States Air Service's Logistics Operations

    National Research Council Canada - National Science Library

    Hunt, Andrew

    1998-01-01

    This historical study details the U.S. Air Service's logistics operations at home and abroad in an attempt to determine the relationship between the process and more recently established logistic principles...

  15. United States Air Force Agency Financial Report 2013

    Science.gov (United States)

    2013-01-01

    the DoD and number two in the federal government for its purchase and on site production of green power. The Air Force more than doubled its number...protect the contract work from state or local taxation , liens or attachment by the contractor’s creditors, transfer of property, or disposition in...the Air Force’s jurisdiction . The fund is available to such institutions or organizations subject to the terms of the gift, device, or bequest

  16. COMPARATIVE ANALYSIS OF PHRASEOLOGICAL UNITS WITH LEXICAL UNIT ВОЗДУХ/AIR/L’AIR IN RUSSIAN, ENGLISH AND FRENCH

    Directory of Open Access Journals (Sweden)

    Lineva, E.

    2017-03-01

    Full Text Available The perception and interpretation of the realia surrounding us is different among the representatives of different nations of the world. It manifests itself very clearly in phraseological units of the language as idioms accumulate the knowledge of the people and reflect culture, history, wisdom, beliefs, customs and traditions of the certain ethnic group. Comparative syntactic and grammatical analysis of phraseological units with the word воздух/air/l'air in the Russian, English and French languages represented in the article can reveal some aspects of the national mindset, linguistic and cultural peculiarities of the three nationalities.

  17. Performance Evaluation of the United Nations Environment Programme Air Quality Unit

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Reference data represents reference monitoring data associated with EPA-operated air monitoring equipment located at its AIRS test site in the Research Triangle...

  18. Desain Mobile Unit Instalasi Pengolahan Air Minum Untuk Kondisi Darurat Bencana Banjir Menggunakan Membran Mikrofiltrasi

    Directory of Open Access Journals (Sweden)

    Angie Prabhata Putra

    2015-03-01

    Full Text Available Banjir dan kekeringan merupakan sebuah fenomena yang rutin dihadapi di berbagai daerah dengan kerugian yang tidak kecil contohnya di wilayah Jabodetabek pada bulan februari tahun 2007, banjir yang terjadi selama 5 hari mencapai kerugian sekitar 8,6 triliyun rupiah. Saat terjadi banjir pengungsi sangat sulit untuk mendapat air bersih maupun air minum, di karenakan sumur penduduk yang dipenuhi lumpur dan kotoran. Kesulitan dalam memperoleh air bersih maupun air minum pada saat maupun paska bencana banjir, berdampak pada timbulnya berbagai penyakit terkait air bersih yaitu seperti muntaber, diare dan gatal-gatal. Oleh karena itu diperlukan solusi atau penanggulangan masalah air bersih dan air siap minum baik saat maupun paska bencana banjir. Menurut buku Introduction to International Disaster Management (2007, disebutkan bahwa ada beberapa alternatif dalam penyediaan air bersih dan air siap minum pada saat kondisi banjir yaitu  penyediaan air melalui tangki truk, atau dari tangki yang di datangkan  dari luar daerah banjir, melakukan proses pengolahan air banjir itu sendiri untuk menghasilkan air bersih sebagai contoh menggunakan filter. Solusi dalam hal masalah ini adalah pengolahan air minum yang berbasis mobile water treatment. Dalam kaitan tentang masalah ini perlu adanya perencanaan tentang desain instalasi pengolahan air minum secara mobile untuk kondisi darurat bencana banjir. Dalam hal ini rencana desain atau DED (Detail Engineering Design yang akan digunakan adalah mobile water treatment membran mikrofiltrasi, keuntungan dari menggunakan membran ini adalah dapat menyisihkan bakteri patogenik dan beberapa jenis virus. Pada perencanaan ini direncanakan unit-unit sebelum dan sesudah membran mikrofiltrasi agar kualitas air hasil pengolahan (effluent memenuhi baku mutu air siap minum yang sesuai dengan PERMENKES RI No.492/MEN.KES/PER/IV/2010.

  19. Evaluation of High-Performance Rooftop HVAC Unit Naval Air Station Key West, Florida

    Energy Technology Data Exchange (ETDEWEB)

    Howett, Daniel H. [ORNL; Desjarlais, Andre Omer [ORNL; Cox, Daryl [ORNL

    2018-01-01

    This report documents performance of a high performance rooftop HVAC unit (RTU) at Naval Air Station Key West, FL. This report was sponsored by the Federal Energy Management Program as part of the "High Performance RTU Campaign".

  20. Radioactive air emissions notice of construction portable/temporary radioactive air emission units - August 1998

    International Nuclear Information System (INIS)

    FRITZ, D.W.

    1999-01-01

    This notice of construction (NOC) requests a categorical approval for construction and operation of three types of portable/temporary radionuclide airborne emission units (PTRAEUs). These three types are portable ventilation-filter systems (Type I), mobile sample preparation facilities (Type II), and mobile sample screening and analysis facilities (Type III). Approval of the NOC application is intended to allow construction and operation of the three types of PTRAEUs without prior project-specific approval. Environmental cleanup efforts on the Hanford Site often require the use of PTRAEUs. The PTRAEUs support site characterization activities, expedited response actions (ERAs), sampling and monitoring activities, and other routine activities. The PTRAEUs operate at various locations around the Hanford Site. Radiation Air Emissions Program, Washington Administrative Code (WAC) 246-247, requires that the Washington State Department of Health (WDOH) be notified before construction of any new emission that would release airborne radioactivity. The WDOH also must receive notification before any modification of an existing source. This includes changes in the source term or replacement of emission control equipment that might significantly contribute to the offsite maximum dose from a licensed facility. During site characterization activities, ERAs, sampling and monitoring activities, and other routine activities, the PTRAEUs might require startup immediately. The notification period hampers efforts to complete such activities in an effective and timely manner. Additionally, notification is to be submitted to the WDOH when the PTRAEUs are turned off. The U.S. Department of Energy, Richland Operations Office (DOE-RL) potentially could generate several notifications monthly. The WDOH would be required to review and provide approval on each NOC as well as review the notices of discontinued sources. The WDOH regulation also allows facilities the opportunity to request a

  1. A Case Study On Human Capital Mismanagement In The United States Air Force

    Science.gov (United States)

    2016-05-08

    AIR COMMAND AND STAFF COLLEGE AIR UNIVERSITY A Case Study on Human Capital Mismanagement in the United States Air Force By John P...Force does not effectively manage its human capital to develop and retain a technically literate acquisitions workforce. A detailed look at the...Several solutions are suggested to improve the human capital management and increase the quality and relevancy of the acquisitions community at

  2. Air and Weather Seychelles Integrated Science. [Teacher and Pupil Booklets]. Unit 2.

    Science.gov (United States)

    Brophy, M.; Fryars, M.

    Seychelles Integrated Science (SIS), a 3-year laboratory-based science program for students (ages 11-15) in upper primary grades 7, 8, and 9, was developed from an extensive evaluation and modification of previous P7-P9 materials. This P7 SIS unit focuses on: (1) the importance of air and air pressure in students' everyday lives; (2) oxidation…

  3. Tree and forest effects on air quality and human health in the United States

    Science.gov (United States)

    David J. Nowak; Satoshi Hirabayashi; Allison Bodine; Eric. Greenfield

    2014-01-01

    Trees remove air pollution by the interception of particulate matter on plant surfaces and the absorption of gaseous pollutants through the leaf stomata. However, the magnitude and value of the effects of trees and forests on air quality and human health across the United States remains unknown. Computer simulations with local environmental data reveal that trees and...

  4. Air pollution removal by urban trees and shrubs in the United States

    Science.gov (United States)

    David J. Nowak; Daniel E. Crane; Jack C. Stevens

    2006-01-01

    A modeling study using hourly meteorological and pollution concentration data from across the coterminous United States demonstrates that urban trees remove large amounts of air pollution that consequently improve urban air quality. Pollution removal (03, PM10, NO2, SO2, CO)...

  5. Air Filtration as Protection against Fouling of Ventilation and Air Conditioning Units

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Lajčíková, Ariana

    2005-01-01

    Currently, air filters are one of the most critical components of air treatment systems as they decontaminate the air delivered to living space. During the operation, however, the level of harmful surface deposits increases, and at certain times, an uncleaned filter can itself become a source...... of undesirable contaminents influencing negatively the IAQ of a living space. This is the phenomenon that has been a subject of the current research. The article presents a new, alternative view on indoor air contaminents and filtration requirements. It describes alternative means of filtration and assesses...... issues of inadequate maintenance and/or long term use of applied air filters. An experimental method of evealuating the air quality by means of chemical analysis and state-of-the-art spectrometer is also described....

  6. Connecting United States Air Force Core Values to Mission Accomplishment

    Science.gov (United States)

    2014-06-04

    Ariely. “The Dishonesty of Honest People: A Theory of Self- Concept Maintenance.” Journal of Marketing Research XLV, no. December (2008): 633– 644. http...From Air Force Academy in Cheating Scandal." Chronicle Of Higher Education 53, no. 36 (May 11, 2007): 46. Academic Search Premier, EBSCOhost (accessed

  7. Simple ADC unit for cosmic ray air shower experiments

    Energy Technology Data Exchange (ETDEWEB)

    Goswami, G C; Ghosh, B; Ghoshdastidar, M R; Sengupta, S K; Chaudhuri, N [North Bengal Univ., Darjeeling (India). Dept. of Physics

    1982-02-01

    The design of a new low cost analog-to-digital converter system is described. It is based upon the method of linearising the charging process of a storage condenser and is controlled by logic gates. Its tested characteristics have been found to be reliable for application in cosmic ray air shower experiments.

  8. Extreme coal handling

    Energy Technology Data Exchange (ETDEWEB)

    Bradbury, S; Homleid, D. [Air Control Science Inc. (United States)

    2004-04-01

    Within the journals 'Focus on O & M' is a short article describing modifications to coal handling systems at Eielson Air Force Base near Fairbanks, Alaska, which is supplied with power and heat from a subbituminous coal-fired central plant. Measures to reduce dust include addition of an enclosed recirculation chamber at each transfer point and new chute designs to reduce coal velocity, turbulence, and induced air. The modifications were developed by Air Control Science (ACS). 7 figs., 1 tab.

  9. AIR POLLUTION: Emissions from Older Electricity Generating Units

    National Research Council Canada - National Science Library

    2002-01-01

    .... While fossil fuels-coal, natural gas, and oil-account for more than two thirds of our electricity, generating units that burn these fuels are major sources of airborne emissions that pose human...

  10. The United States Air Force Academy: A Bibliography: 1968 - 1972

    Science.gov (United States)

    1972-09-01

    Hist - Aerospace Historian Aero Med - Aerospace Medicine Air Reservist Airman America Armed Forces Compt - Armed Forces Comptroller Armed Forces J...center for aviary medicine . Airman 15:48, May 1971. 235 Jeans, Kit. Children learn at Academy school--CHAP pro- gram. AF Times 30:26, 29 Apr...Indoctrination 10355 Merit lists 10356 Organization 10330 Wing strength 10354 Marihuana incidents 10912 Marriage of cadet 10326

  11. United States Air Force Annual Financial Statement 2011

    Science.gov (United States)

    2011-01-01

    detection and two and three dimensional imaging which could be very useful to the warfighter. Furthermore, by keeping the data, forensic analysis can be...program completed Initial Operational Test and Evaluation ( IOT &E). The Air Force provided the RQ-4B Global Hawk Block 30 to the Warfighter prior to the...completion of an IOT &E report because the Warfighter requested and needed that capability. Most findings identified during IOT &E were quickly

  12. 76 FR 7096 - Minimum Quality and Handling Standards for Domestic and Imported Peanuts Marketed in the United...

    Science.gov (United States)

    2011-02-09

    ... DEPARTMENT OF AGRICULTURE Agricultural Marketing Service 7 CFR Part 996 [Doc. No. AMS-FV-10-0030... in the United States; Section 610 Review AGENCY: Agricultural Marketing Service, USDA. ACTION: Confirmation of regulations. SUMMARY: This action summarizes the results under the criteria contained in...

  13. Handling high predictor dimensionality in slope-unit-based landslide susceptibility models through LASSO-penalized Generalized Linear Model

    KAUST Repository

    Camilo, Daniela Castro

    2017-08-30

    Grid-based landslide susceptibility models at regional scales are computationally demanding when using a fine grid resolution. Conversely, Slope-Unit (SU) based susceptibility models allows to investigate the same areas offering two main advantages: 1) a smaller computational burden and 2) a more geomorphologically-oriented interpretation. In this contribution, we generate SU-based landslide susceptibility for the Sado Island in Japan. This island is characterized by deep-seated landslides which we assume can only limitedly be explained by the first two statistical moments (mean and variance) of a set of predictors within each slope unit. As a consequence, in a nested experiment, we first analyse the distributions of a set of continuous predictors within each slope unit computing the standard deviation and quantiles from 0.05 to 0.95 with a step of 0.05. These are then used as predictors for landslide susceptibility. In addition, we combine shape indices for polygon features and the normalized extent of each class belonging to the outcropping lithology in a given SU. This procedure significantly enlarges the size of the predictor hyperspace, thus producing a high level of slope-unit characterization. In a second step, we adopt a LASSO-penalized Generalized Linear Model to shrink back the predictor set to a sensible and interpretable number, carrying only the most significant covariates in the models. As a result, we are able to document the geomorphic features (e.g., 95% quantile of Elevation and 5% quantile of Plan Curvature) that primarily control the SU-based susceptibility within the test area while producing high predictive performances. The implementation of the statistical analyses are included in a parallelized R script (LUDARA) which is here made available for the community to replicate analogous experiments.

  14. Handling high predictor dimensionality in slope-unit-based landslide susceptibility models through LASSO-penalized Generalized Linear Model

    KAUST Repository

    Camilo, Daniela Castro; Lombardo, Luigi; Mai, Paul Martin; Dou, Jie; Huser, Raphaë l

    2017-01-01

    Grid-based landslide susceptibility models at regional scales are computationally demanding when using a fine grid resolution. Conversely, Slope-Unit (SU) based susceptibility models allows to investigate the same areas offering two main advantages: 1) a smaller computational burden and 2) a more geomorphologically-oriented interpretation. In this contribution, we generate SU-based landslide susceptibility for the Sado Island in Japan. This island is characterized by deep-seated landslides which we assume can only limitedly be explained by the first two statistical moments (mean and variance) of a set of predictors within each slope unit. As a consequence, in a nested experiment, we first analyse the distributions of a set of continuous predictors within each slope unit computing the standard deviation and quantiles from 0.05 to 0.95 with a step of 0.05. These are then used as predictors for landslide susceptibility. In addition, we combine shape indices for polygon features and the normalized extent of each class belonging to the outcropping lithology in a given SU. This procedure significantly enlarges the size of the predictor hyperspace, thus producing a high level of slope-unit characterization. In a second step, we adopt a LASSO-penalized Generalized Linear Model to shrink back the predictor set to a sensible and interpretable number, carrying only the most significant covariates in the models. As a result, we are able to document the geomorphic features (e.g., 95% quantile of Elevation and 5% quantile of Plan Curvature) that primarily control the SU-based susceptibility within the test area while producing high predictive performances. The implementation of the statistical analyses are included in a parallelized R script (LUDARA) which is here made available for the community to replicate analogous experiments.

  15. United States Air Force Academy (USAFA) Vertical Axis Wind Turbine.

    Science.gov (United States)

    1980-09-01

    Rotors, SAND76-0131. Albuquerque: July 1977. 10. Oliver, R.C. and P.R. Nixon. "Design Procedure for Coupling Savonius and Darrieus Wind Turbines ", Air...May 17-20, 1976. -65- 16. Blackwell, B.F., R.E. Sheldahl, and L.V. Feltz. Wind Tunnel Performance Data for the Darrieus Wind Turbine with NACA 0012...a 5.8 m/s (13 mph) wind . At 100 rpm, the Darrieus turbine would be fully self-sustaining and acceleration would continue to an operating tip speed

  16. AN EXPERIENCE OF HANDLING MICROBIAL CONTAMINATION OF PRODUCT WATER AT A HAEMODIALYSIS UNIT IN NORTH KARNATAKA OF INDIA

    Directory of Open Access Journals (Sweden)

    Archana Aravindrao Dambal

    2017-09-01

    Full Text Available BACKGROUND Dialysis units need regular prophylactic disinfection of the dialysis water production and distribution circuit without which there can be chronic inflammation among patients using the facility. The aim of the study is to present here our experience in containing an episode of microbial contamination of dialysis water. MATERIALS AND METHODS Our haemodialysis unit had a single pass reverse osmosis plant with facility for pretreatment of raw water and a distribution loop of medical grade PVC (polyvinyl chloride feeding haemodialysis machines, bicarbonate preparation and dialyser reprocessing areas. After installation, the Reverse Osmosis (RO membranes and distribution loop were disinfected every fortnight using formalin. Cultures of product water were sent from various sites in the product water loop every month. RESULTS From January to April 2011, 15 water samples out of 52 water samples grew Pseudomonas aeruginosa with a colony count over 200 Colony-Forming Units (CFU. The average monthly number of haemodialysis was reduced from 84.75 to 65. Two patients had intradialytic pyrexia and two others had mild lower respiratory infection. So, the reverse osmosis plant and product water distribution system were repeatedly disinfected using 2% formalin and 1% bleach ensuring contact time and thorough rinsing to address persistent cultures. When these measures could not eradicate microbial growth, the system was sanitised with Gramicid (48% w/w H2O2 + 500 ppm Ag and all traces of the disinfectant were rinsed away before resuming haemodialysis. CONCLUSION The microbial contamination of dialysis water was eradicated by Gramicid and not by bleach or formalin without any adverse effects after thorough rinsing.

  17. The United States Air Force in Korea 1950-1953

    Science.gov (United States)

    1983-01-01

    volume through various stages of publication. Further appreciation is extended to Mr. Bruce Plumb, Typography and Design Division of the U.S...negative reactions . and. Brown thus destroyed the first Commu- following the collapse of the United nist jet aircraft to be shot down in Nations...Decisions "Enemy reactions developed in the Almond’s forces in those areas. [ron course of our assault operations of the such positions on the eastern

  18. A Historical Analysis of Basic Air Force Doctrine Education within the United States States Air Force Air Command and Staff College, 1947-1987.

    Science.gov (United States)

    1987-09-01

    doctrine, especially joint doctrine. Because of this we make mistakes. I believe that the Air Force needs to develop a formal doctrinallo education...jresenteo arguments for all three points of view, but ne was particularly critical of tne educacional system within tae United States military. He said tnat

  19. [Bacterial contamination of the indoor air in a transplant unit].

    Science.gov (United States)

    Matoušková, Ivanka; Holý, Ondřej

    2013-12-01

    For one year (August 2010 to July 2011), microbial contamination of the indoor air in the Transplant Unit of the Haemato-Oncology Clinic, Olomouc University Hospital was monitored monthly. Twenty sampling sites were singled out and a total of 240 indoor air samples were collected. An MAS-100 air sampler (Merck, GER) was used, air flow rate of 100 liters per minute, 1 minute. The measured values of indoor air temperature were stable. The relative air humidity ranged from 17% to 68%. The highest average value of microbial air contamination was found in the "staff entry room" (1170 CFU/m3). The lowest microbial air contamination (150-250 CFU/m3) was measured in the patient isolation units. The most frequently isolated bacterial strains were coagulase-negative staphylococci (94.3%), followed by Micrococcus spp. (67%) and Bacillus subtilis (11%). It can be assumed that the -source of these airborne bacterial strains are both patients and medical staff. They are classified as -opportunistic pathogens and as such can cause hospital infections among haemato-oncology patients.

  20. [Fungus microbiota in air conditioners in intensive care units in Teresina, Piauí].

    Science.gov (United States)

    Mobin, Mitra; do Amparo Salmito, Maria

    2006-01-01

    With the aim of identifying the fungus microbiota in air conditioners in intensive care units (ICUs) within public and private hospitals in Teresina, Piauí, solid material was collected from ten different ICUs. Thirty-three species of Moniliaceae and Dematiaceae were isolated, which was the first report of these in Piauí. High frequencies of Aspergillus niger Van Tieghem (60%), Aspergillus fumigatus Fres (50%), Trichoderma koningii Oudem (50%) and Aspergillus flavus Link: Fr. (40%) were recorded. The air conditioner cleanliness validity had expired in all the ICUs, and the quantity of colony-forming units exceeded the levels permitted by Law 176/00 from the Ministry of Health. It is important to provide individual protection equipment for professionals, adopt hospital infection control measures, raise the awareness of the presence of fungus infection, improve air circulation around the environment, periodically clean the air conditioners, and make health professionals alert to the importance of these fungi in the hospital environment.

  1. Handling and treatment of low-level radioactive wastes from gaseous diffusion plants in the United States of America

    International Nuclear Information System (INIS)

    Wing, J.F.; Behrend, J.E.

    1984-01-01

    Gaseous diffusion plants in the United States of America currently generate very small quantities of low-level radioactive wastes. These wastes consist primarily of airborne effluent solid trapping media and liquid scrubber solutions, liquid effluent treatment sludges, waste oils and solvents, scrap metals and conventional combustible wastes such as floor sweepings, cleaning rags and shoe covers. In addition to waste emanating from current operations, large quantities of scrap metal generated during the Cascade Improvement Program are stored above ground at each of the diffusion plants. The radionuclides of primary concern are uranium and 99 Tc. Current radioactive waste treatment consists of uranium dissolution in weak acids followed by chemical precipitation and/or solvent extraction for uranium recovery. Current disposal operations consist of above ground storage of scrap metals, shallow land burial of inorganic solids and incineration of combustible wastes. With increased emphasis on reducing the potential for off-site radiological dose, several new treatment and disposal options are being studied and new projects are being planned. One project of particular interest involves the installation of a high temperature incinerator to thermally degrade hazardous organic wastes contaminated with low-level radioactive wastes. Other technologies being studied include fixation of uranium-bearing sludges in concrete before burial, decontamination of scrap metals by smelting and use of specially engineered centralized burial grounds. (author)

  2. A Service in Transition: Forging an Integrated Institutional Identity for the United States Air Force

    Science.gov (United States)

    2010-06-01

    glass ceiling for advancement on the members of the lesser tribes. For that reason, Perry asserts that the Air Force has no choice but to change. 65...quarter century is clear: the Soviets in Afghanistan, the Israelis in Lebanon , the United States in Somalia, Afghanistan, and Iraq. Smaller, irregular...Air Force has used to justify procurement of addition numbers of fifth-generation F-22‘s above the final-buy ceiling (187 aircraft) established by

  3. Smoking in the United States Air Force: Trends, Most Prevalent Diseases and their Association with Cost

    Science.gov (United States)

    2011-09-01

    alcohol use (University of Minnesota, 2010). Tobacco use is one of the most significant health issues that the U.S. military faces today . In 2002, it...rates among the active duty members of the Air Force of the United States. Smoking is a severe phenomenon for the Air Force today because it is...allurement. In addition, they launch special tobacco products for women, the so called “ feminized cigarettes”, trying to create more female smokers

  4. Compressed Air Quality, A Case Study In Paiton Coal Fired Power Plant Unit 1 And 2

    Science.gov (United States)

    Indah, Nur; Kusuma, Yuriadi; Mardani

    2018-03-01

    The compressed air system becomes part of a very important utility system in a Plant, including the Steam Power Plant. In PLN’S coal fired power plant, Paiton units 1 and 2, there are four Centrifugal air compressor types, which produce compressed air as much as 5.652 cfm and with electric power capacity of 1200 kW. Electricity consumption to operate centrifugal compressor is 7.104.117 kWh per year. Compressed air generation is not only sufficient in quantity (flow rate) but also meets the required air quality standards. compressed air at Steam Power Plant is used for; service air, Instrument air, and for fly Ash. This study aims to measure some important parameters related to air quality, followed by potential disturbance analysis, equipment breakdown or reduction of energy consumption from existing compressed air conditions. These measurements include counting the number of dust particles, moisture content, relative humidity, and also compressed air pressure. From the measurements, the compressed air pressure generated by the compressor is about 8.4 barg and decreased to 7.7 barg at the furthest point, so the pressure drop is 0.63 barg, this number satisfies the needs in the end user. The measurement of the number of particles contained in compressed air, for particle of 0.3 micron reaches 170,752 particles, while for the particle size 0.5 micron reaches 45,245 particles. Measurements of particles conducted at several points of measurement. For some point measurements the number of dust particle exceeds the standard set by ISO 8573.1-2010 and also NACE Code, so it needs to be improved on the air treatment process. To see the amount of moisture content in compressed air, it is done by measuring pressure dew point temperature (PDP). Measurements were made at several points with results ranging from -28.4 to 30.9 °C. The recommendation of improving compressed air quality in steam power plant, Paiton unit 1 and 2 has the potential to extend the life of

  5. Canada-United States air quality agreement: Making progress

    International Nuclear Information System (INIS)

    1992-01-01

    The Canada-USA Air Quality Agreement was signed in March 1991. Canada's commitment under the agreement is to reduce emissions of SO 2 in the seven easternmost provinces to 2.3 million tonnes/y by 1994 and to cap these emissions at 3.2 million tonnes/y by 2000; in addition, Canada agrees to reduce nitrogen oxide emissions from stationary sources by 100,000 tonnes/y by 2000 and to implement more stringent nitrogen oxide emission standards for vehicles from 1994-96. The USA agrees to reduce SO 2 emissions by ca 10 million tons/y below 1980 levels by 2000, to achieve a permanent cap of 8.95 million tons/y for electric utilities by 2010, to ensure that industrial emissions do not exceed 5.6 million tons, and to reduce total nitrogen oxide emissions by ca 2 million tons/y below 1980 levels, primarily through new regulations for power plants and automobiles. In Canada, SO 2 emissions are now within 16% of target, with control efforts centered around metal smelters and power plants. In the USA, considerable progress has been made in promulgating regulations that will implement the acid rain control provisions of the agreement. Both countries are sharing information, are continuing a variety of scientific and technical activities, and cooperating in areas such as emission inventorying, atmospheric modelling, deposition monitoring, effects research and monitoring, human health studies, and control technologies. In the USA, market based incentives are being used in controlling acid emissions and are being assessed for their potential use in Canada. 13 figs., 3 tabs

  6. Determination of technical and economic parameters of an ionic transport membrane air separation unit working in a supercritical power plant

    Directory of Open Access Journals (Sweden)

    Kotowicz Janusz

    2016-09-01

    Full Text Available In this paper an air separation unit was analyzed. The unit consisted of: an ionic transport membrane contained in a four-end type module, an air compressor, an expander fed by gas that remains after oxygen separation and heat exchangers which heat the air and recirculated flue gas to the membrane operating temperature (850 °C. The air separation unit works in a power plant with electrical power equal to 600 MW. This power plant additionally consists of: an oxy-type pulverized-fuel boiler, a steam turbine unit and a carbon dioxide capture unit. Life steam parameters are 30 MPa/650 °C and reheated steam parameters are 6 MPa/670 °C. The listed units were analyzed. For constant electrical power of the power plant technical parameters of the air separation unit for two oxygen recovery rate (65% and 95% were determined. One of such parameters is ionic membrane surface area. In this paper the formulated equation is presented. The remaining technical parameters of the air separation unit are, among others: heat exchange surface area, power of the air compressor, power of the expander and auxiliary power. Using the listed quantities, the economic parameters, such as costs of air separation unit and of individual components were determined. These quantities allowed to determine investment costs of construction of the air separation unit. In addition, they were compared with investment costs for the entire oxy-type power plant.

  7. Learning from 25 years of experience with the United States clean air act

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, R.H. [Trinity Consultants Incorporated, Dallas, TX (United States)

    1995-12-31

    Twenty-five years ago, the United States embarked on a quest to attain clean air. President Nixon, in signing the Clean Air Act of 1970, defined clean air as the objective for the `70s. Although enormous progress has been made, much remains to be done. Newly constructed industry is quite clean, but many older facilities continue to operate with antiquated controls. Significant advances have been made in cleaning up the emissions from new automobiles, but two factors have impaired progress. First, cars last longer than they did in 1970, so the average age of the fleet has increased. Second, travel has increased as people have moved to the suburbs. Thus, the emission decreases from clean cars have not been as great as expected. This presentation will address some of the lessons learned from the efforts in the United States to implement clean air programs. In a large number of countries, excessively elaborate studies have been substituted for action programs. Since much is now known about air quality, fairly brief studies can define programs that should be undertaken. What may take longer is developing public support and enthusiasm for improved air quality. In most cases, it is desirable to reduce spending on studies and increase spending on devising and implementing plans, as well as effectively communicating the necessary changes to the public. Balanced spending on studies- and action programs is essential to a sound air quality control program. (author)

  8. Learning from 25 years of experience with the United States clean air act

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, R H [Trinity Consultants Incorporated, Dallas, TX (United States)

    1996-12-31

    Twenty-five years ago, the United States embarked on a quest to attain clean air. President Nixon, in signing the Clean Air Act of 1970, defined clean air as the objective for the `70s. Although enormous progress has been made, much remains to be done. Newly constructed industry is quite clean, but many older facilities continue to operate with antiquated controls. Significant advances have been made in cleaning up the emissions from new automobiles, but two factors have impaired progress. First, cars last longer than they did in 1970, so the average age of the fleet has increased. Second, travel has increased as people have moved to the suburbs. Thus, the emission decreases from clean cars have not been as great as expected. This presentation will address some of the lessons learned from the efforts in the United States to implement clean air programs. In a large number of countries, excessively elaborate studies have been substituted for action programs. Since much is now known about air quality, fairly brief studies can define programs that should be undertaken. What may take longer is developing public support and enthusiasm for improved air quality. In most cases, it is desirable to reduce spending on studies and increase spending on devising and implementing plans, as well as effectively communicating the necessary changes to the public. Balanced spending on studies- and action programs is essential to a sound air quality control program. (author)

  9. Remote handling machines

    International Nuclear Information System (INIS)

    Sato, Shinri

    1985-01-01

    In nuclear power facilities, the management of radioactive wastes is made with its technology plus the automatic techniques. Under the radiation field, the maintenance or aid of such systems is important. To cope with this situation, MF-2 system, MF-3 system and a manipulator system as remote handling machines are described. MF-2 system consists of an MF-2 carrier truck, a control unit and a command trailer. It is capable of handling heavy-weight objects. The system is not by hydraulic but by electrical means. MF-3 system consists of a four-crawler truck and a manipulator. The truck is versatile in its posture by means of the four independent crawlers. The manipulator system is bilateral in operation, so that the delicate handling is made possible. (Mori, K.)

  10. Performance Evaluation of the United Nations Environment Programme Air Quality Monitoring Unit

    Science.gov (United States)

    A request for technical collaboration between the UNEP and the US EPA resulted in the establishment of a MCRADA. The purpose of this agreement was to evaluate an air quality monitoring system (referred to as the UNEP pod) developed by the UNEP for use in environmental situations ...

  11. Comparison of ultrafiltration and dissolved air flotation efficiencies in industrial units during the papermaking process

    OpenAIRE

    Monte Lara, Concepción; Ordóñez Sanz, Ruth; Hermosilla Redondo, Daphne; Sánchez González, Mónica; Blanco Suárez, Ángeles

    2011-01-01

    The efficiency of an ultrafiltration unit has been studied and compared with a dissolved air flotation system to get water with a suited quality to be reused in the process. The study was done at a paper mill producing light weight coated paper and newsprint paper from 100% recovered paper. Efficiency was analysed by removal of turbidity, cationic demand, total and dissolved chemical oxygen demand, hardness, sulphates and microstickies. Moreover, the performance of the ultrafiltration unit an...

  12. Carcinogenic Air Toxics Exposure and Their Cancer-Related Health Impacts in the United States.

    Directory of Open Access Journals (Sweden)

    Ying Zhou

    Full Text Available Public health protection from air pollution can be achieved more effectively by shifting from a single-pollutant approach to a multi-pollutant approach. To develop such multi-pollutant approaches, identifying which air pollutants are present most frequently is essential. This study aims to determine the frequently found carcinogenic air toxics or hazardous air pollutants (HAPs combinations across the United States as well as to analyze the health impacts of developing cancer due to exposure to these HAPs. To identify the most commonly found carcinogenic air toxics combinations, we first identified HAPs with cancer risk greater than one in a million in more than 5% of the census tracts across the United States, based on the National-Scale Air Toxics Assessment (NATA by the U.S. EPA for year 2005. We then calculated the frequencies of their two-component (binary, and three-component (ternary combinations. To quantify the cancer-related health impacts, we focused on the 10 most frequently found HAPs with national average cancer risk greater than one in a million. Their cancer-related health impacts were calculated by converting lifetime cancer risk reported in NATA 2005 to years of healthy life lost or Disability-Adjusted Life Years (DALYs. We found that the most frequently found air toxics with cancer risk greater than one in a million are formaldehyde, carbon tetrachloride, acetaldehyde, and benzene. The most frequently occurring binary pairs and ternary mixtures are the various combinations of these four air toxics. Analysis of urban and rural HAPs did not reveal significant differences in the top combinations of these chemicals. The cumulative annual cancer-related health impacts of inhaling the top 10 carcinogenic air toxics included was about 1,600 DALYs in the United States or 0.6 DALYs per 100,000 people. Formaldehyde and benzene together contribute nearly 60 percent of the total cancer-related health impacts. Our study shows that although

  13. Carcinogenic Air Toxics Exposure and Their Cancer-Related Health Impacts in the United States.

    Science.gov (United States)

    Zhou, Ying; Li, Chaoyang; Huijbregts, Mark A J; Mumtaz, M Moiz

    2015-01-01

    Public health protection from air pollution can be achieved more effectively by shifting from a single-pollutant approach to a multi-pollutant approach. To develop such multi-pollutant approaches, identifying which air pollutants are present most frequently is essential. This study aims to determine the frequently found carcinogenic air toxics or hazardous air pollutants (HAPs) combinations across the United States as well as to analyze the health impacts of developing cancer due to exposure to these HAPs. To identify the most commonly found carcinogenic air toxics combinations, we first identified HAPs with cancer risk greater than one in a million in more than 5% of the census tracts across the United States, based on the National-Scale Air Toxics Assessment (NATA) by the U.S. EPA for year 2005. We then calculated the frequencies of their two-component (binary), and three-component (ternary) combinations. To quantify the cancer-related health impacts, we focused on the 10 most frequently found HAPs with national average cancer risk greater than one in a million. Their cancer-related health impacts were calculated by converting lifetime cancer risk reported in NATA 2005 to years of healthy life lost or Disability-Adjusted Life Years (DALYs). We found that the most frequently found air toxics with cancer risk greater than one in a million are formaldehyde, carbon tetrachloride, acetaldehyde, and benzene. The most frequently occurring binary pairs and ternary mixtures are the various combinations of these four air toxics. Analysis of urban and rural HAPs did not reveal significant differences in the top combinations of these chemicals. The cumulative annual cancer-related health impacts of inhaling the top 10 carcinogenic air toxics included was about 1,600 DALYs in the United States or 0.6 DALYs per 100,000 people. Formaldehyde and benzene together contribute nearly 60 percent of the total cancer-related health impacts. Our study shows that although there are many

  14. An evaluation tool kit of air quality micro-sensing units

    Czech Academy of Sciences Publication Activity Database

    Fishbain, B.; Lerner, U.; Castell-Balaguer, N.; Cole-Hunter, T.; Popoola, O.; Broday, D. M.; Martinez Iniguez, T.; Nieuwenhuijsen, M.; Jovasevic-Stojanovic, M.; Topalovic, D.; Roderic, L.J.; Gaela, K.; Etzion, Y.; Kizel, F.; Golumbic, Y.N.; Baram-Tsabari, A.; Yacobi, T.; Drahler, D.; Robinson, J.A.; Kocman, D.; Horvát, M.; Švecová, Vlasta; Arpaci, A.; Bartoňová, A.

    2017-01-01

    Roč. 575, jan (2017), s. 639-648 ISSN 0048-9697 Institutional support: RVO:68378041 Keywords : air quality * environmental monitoring * micro sensing units Subject RIV: DN - Health Impact of the Environment Quality OBOR OECD: Public and environmental health Impact factor: 4.900, year: 2016

  15. Experimental studies on improvement of coefficient of performance of window air conditioning unit

    Directory of Open Access Journals (Sweden)

    Tharves Mohideen Sheik Ismail

    2017-01-01

    Full Text Available This paper presents the performance analysis of a window air conditioner unit incorporated with wick less loop heat pipes (WLHP. The WLHP are located on the evaporator side of the air conditioning unit. The working medium for the WLHP is R134a refrigerant gas, an alternate refrigerant. The supply and return humidity of room air, the heat removal rat, and the coefficient of performance of the unit are analyzed for various ambient and room temperatures before and after incorporation of WLHP. The performance curves are drawn by comparing the power consumption and humidity collection rates for various room and ambient temperatures. The results show that coefficient of performance of the unit is improved by 18% to 20% after incorporation of WLHP due to pre-cooling of return air by WLHP, which reduces the thermal load on compressor. Similarly, the energy consumption is reduced by 20% to 25% due to higher thermostat setting and the humidity collection is improved by 35% due to pre-cooling effect of WLHP. The results are tabulated and conclusion drawn is presented based on the performance.

  16. Evaluating ozone air pollution effects on pines in the western United States

    Science.gov (United States)

    Paul R. Miller; Kenneth W. Stolte; Daniel M. Duriscoe; John Pronos

    1996-01-01

    Historical and technical background is provided about ozone air pollution effects on ponderosa (Pinus ponderosa Dougl. ex Laws) and Jeffrey (P. jeffreyi Grev. and Balf.) pines in forests of the western United States. The principal aim is to document the development of field survey methods to be applied to assessment of chronic...

  17. Classification, Social Contracts, Obligations, Civil Rights, and the Supreme Court: Sutton v. United Air Lines.

    Science.gov (United States)

    Turnbull, H. Rutherford, III; Stowe, Matthew J.

    2001-01-01

    This article analyzes the 1999 decision of the U.S. Supreme Court, Sutton v. United Air Lines, as it pertains to people with disabilities, especially students covered by federal education and civil rights legislation. It sets out implications of the decision for special and general educators as they engage in Individualized Education Program…

  18. The application of fuzzy control on energy saving for multi-unit room air-conditioners

    International Nuclear Information System (INIS)

    Chiou, C.B.; Chiou, C.H.; Chu, C.M.; Lin, S.L.

    2009-01-01

    Most research, on energy saving methods for air-conditioners have focused on large chillers as its subject. As most school offices, laboratories, and classrooms are equipped with unitary systems for air-conditioning, this paper discusses methods for energy savings with regard to unitary systems. This paper will put forward the fuzzy temperature control method for multi-unit air-conditioners to enhance energy efficiency. The results show that the use of fuzzy control is efficient for energy saving as well as causing temperature control be steadier, even if there is a change to the thermal loading, the fuzzy control system is able to control the air-conditioning in stable conditions

  19. Plate heat exchangers in air conditioning applications. Development of air-coolers, air-heaters and air-conditioning units with low pressure loss. Plattenwaermetauscher in raumlufttechnischen Anlagen. Entwicklung stroemungsoptimierter Luftkuehler, Lufterhitzer und Klimageraete

    Energy Technology Data Exchange (ETDEWEB)

    Bach, H; Diemer, R; Eisenmann, G; Goettling, D; Madjidi, M

    1989-08-01

    To prepare the development of a water to air plate heat exchanger the state of the art, i.e. the technological knowhow and the design basis are given. The concept and ideas are presented which lead to a slightly wavy plate. Furthermore an exemplary design of a plate heat exchanger and an air-conditioning unit is described and finally the application of plate heat exchangers as direct evaporators and the potential icing problems are investigated. Comparing measured and calculated data shows that the performance of plates with plane surfaces can be predicted fairly well by the presented design methods. The performance of plates with strongly wavy surface however has to be measured. Optimization calculations yield to an air gap of slightly over 4 mm. Comparison with an air-conditioning unit demonstrates that the strongest advantage is for the air cooler (one third of the pressure loss) that a new concept of an air-conditioning unit has lower losses in the fan unit and that it does not need an eliminator. This results in half the volume for the new unit, in a pressure drop of 88%, fan power of 90% and fan revolutions of 50%. (orig./GL).

  20. A preliminary assessment of the Montréal process indicators of air pollution for the United States

    Science.gov (United States)

    John W. Coulston; Kurt H. Riitters; Grethchen C. Smith

    2004-01-01

    Air pollutants pose a risk to forest health and vitality in the United States. Here we present the major findings from a national scale air pollution assessment that is part of the United States’ 2003 Report on Sustainable Forests. We examine trends and the percent forest subjected to specific levels of ozone and wet deposition of sulfate, nitrate, and ammonium....

  1. Experimental study on airflow fluctuation characteristic of an underfloor air supply terminal unit

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jinping [School of Electric Power, South China University of Technology, Guangzhou 510640 (China); State Key Laboratory of Subtropical Building Science, South China University of Technology, Guangzhou 510640 (China); Wu, Yanfang [Design Institute of Guangzhou Metro Corporation, Guangzhou 510010 (China)

    2010-11-15

    In order to investigate dynamic characteristic of underfloor air supply terminal unit, an IFV900A hot-wire anemometer was used to measure the corresponding velocity field. Turbulence intensity and power spectrum density exponent of air velocity signal were analyzed. The result showed that the outlet velocity distribution of underfloor air supply terminal unit was uniform. With increment of height, the velocity distribution trends to be uniform. Two velocity attenuation regions appear during airflow development. Turbulence intensity changes obviously with height. It is lower than that of mechanical wind. Turbulence intensity goes up with the increment of jetting distance. Power spectrum density exponent trends to the value of natural wind with increase of jetting distance and decrease of wind velocity. The exponent value approaches to the value of typical natural wind for the air velocity is 0.5 m/s under high supply air rate. With airflow diffusion, the fluctuation characteristic of airflow varies obviously with the jetting direction. The fluctuation characteristic of airflow changes to that of natural wind with the increase of height which can improve comfort of indoor environment. (author)

  2. Integration optimisation of elevated pressure air separation unit with gas turbine in an IGCC power plant

    International Nuclear Information System (INIS)

    Han, Long; Deng, Guangyi; Li, Zheng; Wang, Qinhui; Ileleji, Klein E.

    2017-01-01

    Highlights: • IGCC thermodynamic model was setup carefully. • Simulations focus on integration between an elevated pressure ASU with gas turbine. • Different recommended solutions from those of low pressure ASUs are figured out. • Full N 2 injection and 80% air extraction was suggested as the optimum integration. - Abstract: The integration optimisation between an elevated pressure air separation unit (EP-ASU) and gas turbine is beneficial to promote net efficiency of an integrated gasification combined cycle (IGCC) power plant. This study sets up the thermodynamic model for a 400 MW plant specially coupled with an EP-ASU, aiming to examine system performances under different integrations and acquire the optimum solution. Influences of air extraction rate at conditions of without, partial and full N 2 injection, as well as the effects of N 2 injection rate when adopting separate ASU, partial and full integrated ASU were both analysed. Special attention has been paid to performance differences between utilising an EP-ASU and a low pressure unit. Results indicated that integration solution with a separate EP-ASU or without N 2 injection would not be reasonable. Among various recommended solutions for different integration conditions, N 2 injection rate increased with the growth of air extraction rate. The integration with an air extraction rate of 80% and full N 2 injection was suggested as the optimum solution. It is concluded that the optimum integration solution when adopting an EP-ASU is different from that using a low pressure one.

  3. China’s international trade and air pollution in the United States

    Science.gov (United States)

    Lin, Jintai; Pan, Da; Davis, Steven J.; Zhang, Qiang; He, Kebin; Wang, Can; Streets, David G.; Wuebbles, Donald J.; Guan, Dabo

    2014-01-01

    China is the world’s largest emitter of anthropogenic air pollutants, and measurable amounts of Chinese pollution are transported via the atmosphere to other countries, including the United States. However, a large fraction of Chinese emissions is due to manufacture of goods for foreign consumption. Here, we analyze the impacts of trade-related Chinese air pollutant emissions on the global atmospheric environment, linking an economic-emission analysis and atmospheric chemical transport modeling. We find that in 2006, 36% of anthropogenic sulfur dioxide, 27% of nitrogen oxides, 22% of carbon monoxide, and 17% of black carbon emitted in China were associated with production of goods for export. For each of these pollutants, about 21% of export-related Chinese emissions were attributed to China-to-US export. Atmospheric modeling shows that transport of the export-related Chinese pollution contributed 3–10% of annual mean surface sulfate concentrations and 0.5–1.5% of ozone over the western United States in 2006. This Chinese pollution also resulted in one extra day or more of noncompliance with the US ozone standard in 2006 over the Los Angeles area and many regions in the eastern United States. On a daily basis, the export-related Chinese pollution contributed, at a maximum, 12–24% of sulfate concentrations over the western United States. As the United States outsourced manufacturing to China, sulfate pollution in 2006 increased in the western United States but decreased in the eastern United States, reflecting the competing effect between enhanced transport of Chinese pollution and reduced US emissions. Our findings are relevant to international efforts to reduce transboundary air pollution. PMID:24449863

  4. Feasibility for the medium efficiency filter as a postfilter in the air cleaning unit

    International Nuclear Information System (INIS)

    Lim, H. S.; Jung, D. Y.; Byun, S. C.; Kim, S. H.

    2002-01-01

    The Air Cleaning Unit (ACU) is provided in a nuclear facility to filter the radioactive materials in gaseous effluents released from the facility during normal operation and during a postulated accident. The Air Cleaning Unit (ACU) consists of pre-HEPA filters, charcoal adsorber, post HEPA filters, fans, etc. The charcoal filters keep on-site dose and off-site effluents ALARA, consistent with regulatory requirements. The function of HEPA filter downstream of charcoal(carbon) adsorber in ACU is to catch potential radioactive carbon dust and to be a backup in the event of failure of upstream HEPA. Previous Regulatory Guide use only post HEPA filter of charcoal adsorber downstream but the Regulatory Guide of current revisions allows use of 95% dust spot efficiency filters in lieu of HEPA at the downstream of the carbon adsorber. In this paper is described that the background information of filters, Current Regulatory Guide of revised by the United States Nuclear Regulatory Commission and the feasibility for the medium efficiency filter as a carbon adsorber post filter in the Air Cleaning Unit

  5. International trade and air pollution: estimating the economic costs of air emissions from waterborne commerce vessels in the United States.

    Science.gov (United States)

    Gallagher, Kevin P

    2005-10-01

    Although there is a burgeoning literature on the effects of international trade on the environment, relatively little work has been done on where trade most directly effects the environment: the transportation sector. This article shows how international trade is affecting air pollution emissions in the United States' shipping sector. Recent work has shown that cargo ships have been long overlooked regarding their contribution to air pollution. Indeed, ship emissions have recently been deemed "the last unregulated source of traditional air pollutants". Air pollution from ships has a number of significant local, national, and global environmental effects. Building on past studies, we examine the economic costs of this increasing and unregulated form of environmental damage. We find that total emissions from ships are largely increasing due to the increase in foreign commerce (or international trade). The economic costs of SO2 pollution range from dollars 697 million to dollars 3.9 billion during the period examined, or dollars 77 to dollars 435 million on an annual basis. The bulk of the cost is from foreign commerce, where the annual costs average to dollars 42 to dollars 241 million. For NOx emissions the costs are dollars 3.7 billion over the entire period or dollars 412 million per year. Because foreign trade is driving the growth in US shipping, we also estimate the effect of the Uruguay Round on emissions. Separating out the effects of global trade agreements reveals that the trade agreement-led emissions amounted to dollars 96 to dollars 542 million for SO2 between 1993 and 2001, or dollars 10 to dollars 60 million per year. For NOx they were dollars 745 million for the whole period or dollars 82 million per year. Without adequate policy responses, we predict that these trends and costs will continue into the future.

  6. Compressed air as a source of inhaled oxidants in intensive care units.

    Science.gov (United States)

    Thibeault, D W; Rezaiekhaligh, M H; Ekekezie, I; Truog, W E

    1999-01-01

    Exhaled gas from mechanically ventilated preterm infants was found to have similar oxidant concentrations, regardless of lung disease, leading to the hypothesis that wall outlet gases were an oxidant source. Oxidants in compressed room air and oxygen from wall outlets were assessed in three hospitals. Samples were collected by flowing wall outlet gas through a heated humidifier and an ice-packed condenser. Nitric oxide (NO) was measured in intensive care room air and in compressed air with and without a charcoal filter using a Sievers NOA280 nitric oxide analyzer (Boulder, CO). Oxidants were measured by spectrophotometry and expressed as nMol equivalents of H2O2/mL. The quantity of oxidant was also expressed as amount of Vitamin C (nMol/mL) added until the oxidant was nondetectable. This quantity of Vitamin C was also expressed in Trolox Equivalent Antioxidant Capacity (TEAC) units (mMol/L). Free and total chlorine were measured with a Chlorine Photometer. Oxidants were not found in compressed oxygen and were only found in compressed air when the compression method used tap water. At a compressed room air gas flow of 1.5 L/min, the total volume of condensate was 20.2 +/- 1 mL/hr. The oxidant concentration was 1.52 +/- 0.09 nMol/mL equivalents of H2O2/mL of sample and 30.8 +/- 1.2 nMol/hr; 17.9% of that found in tap water. Oxidant reduction required 2.05 +/-0.12 nMol/mL vitamin C, (1.78 +/- 0.1 x 10(-3) TEAC units). Free and total chlorine in tap water were 0.3 +/- 0.02 mg/mL and 2.9 +/- 0.002 mg/mL, respectively. Outlet gas contained 0.4 +/- 0.06 mg/mL and 0.07 + 0.01 mg/mL total and free chlorine, respectively; both 14% of tap water. When a charcoal filter was installed in the hospital with oxidants in compressed air, oxidants were completely removed. Nursery room air contained 12.4 +/- 0.5 ppb NO; compressed wall air without a charcoal filter, 8.1 +/- 0.1 ppb and compressed air with a charcoal filter 12.5 +/- 0.5 ppb. A charcoal filter does not remove NO. (Table

  7. Effects of air pollution on ecosystems and biological diversity in the eastern United States.

    Science.gov (United States)

    Lovett, Gary M; Tear, Timothy H; Evers, David C; Findlay, Stuart E G; Cosby, B Jack; Dunscomb, Judy K; Driscoll, Charles T; Weathers, Kathleen C

    2009-04-01

    Conservation organizations have most often focused on land-use change, climate change, and invasive species as prime threats to biodiversity conservation. Although air pollution is an acknowledged widespread problem, it is rarely considered in conservation planning or management. In this synthesis, the state of scientific knowledge on the effects of air pollution on plants and animals in the Northeastern and Mid-Atlantic regions of the United States is summarized. Four air pollutants (sulfur, nitrogen, ozone, and mercury) and eight ecosystem types ranging from estuaries to alpine tundra are considered. Effects of air pollution were identified, with varying levels of certainty, in all the ecosystem types examined. None of these ecosystem types is free of the impacts of air pollution, and most are affected by multiple pollutants. In aquatic ecosystems, effects of acidity, nitrogen, and mercury on organisms and biogeochemical processes are well documented. Air pollution causes or contributes to acidification of lakes, eutrophication of estuaries and coastal waters, and mercury bioaccumulation in aquatic food webs. In terrestrial ecosystems, the effects of air pollution on biogeochemical cycling are also very well documented, but the effects on most organisms and the interaction of air pollution with other stressors are less well understood. Nevertheless, there is strong evidence for effects of nitrogen deposition on plants in grasslands, alpine areas, and bogs, and for nitrogen effects on forest mycorrhizae. Soil acidification is widespread in forest ecosystems across the eastern United States and is likely to affect the composition and function of forests in acid-sensitive areas over the long term. Ozone is known to cause reductions in photosynthesis in many terrestrial plant species. For the most part, the effects of these pollutants are chronic, not acute, at the exposure levels common in the eastern United States. Mortality is often observed only at experimentally

  8. Air Quality and Respiratory Health among Adolescents from the United Arab Emirates

    OpenAIRE

    Barakat-Haddad, Caroline; Zhang, Sheng; Siddiqua, Ayesha; Dghaim, Rania

    2015-01-01

    Purpose. To examine the role of air quality in relation to chronic bronchitis, emphysema, asthma, wheeze, and dry cough among adolescents from the United Arab Emirates (UAE). Methods. A survey was administered on 6,363 adolescents from 9 UAE regions. Data consists of demographic, socioeconomic, residential, and behavioural variables, such as location of residence, residing near industry/gas stations/dumpsites/construction sites, residing near overhead power line/plants, exposure to tobacco, r...

  9. Retrofitting Inefficient Rooftop Air-Conditioning Units Reduces U.S. Navy Energy Use (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2014-04-01

    As part of the U.S. Navy's overall energy strategy, the National Renewable Energy Laboratory (NREL) partnered with the Naval Facilities Engineering Command (NAVFAC) to demonstrate market-ready energy efficiency measures, renewable energy generation, and energy systems integration. One such technology - retrofitting rooftop air-conditioning units with an advanced rooftop control system - was identified as a promising source for reducing energy use and costs, and can contribute to increasing energy security.

  10. Air quality and human health impacts of grasslands and shrublands in the United States

    Science.gov (United States)

    Gopalakrishnan, Varsha; Hirabayashi, Satoshi; Ziv, Guy; Bakshi, Bhavik R.

    2018-06-01

    Vegetation including canopy, grasslands, and shrublands can directly sequester pollutants onto the plant surface, resulting in an improvement in air quality. Until now, several studies have estimated the pollution removal capacity of canopy cover at the level of a county, but no such work exists for grasslands and shrublands. This work quantifies the air pollution removal capacity of grasslands and shrublands at the county-level in the United States and estimates the human health benefits associated with pollution removal using the i-Tree Eco model. Sequestration of pollutants is estimated based on the Leaf Area Index (LAI) obtained from the Moderate Resolution Imaging Spectroradiometer (MODIS) derived dataset estimates of LAI and the percentage land cover obtained from the National Land Cover Database (NLCD) for the year 2010. Calculation of pollution removal capacity using local environmental data indicates that grasslands and shrublands remove a total of 6.42 million tonnes of air pollutants in the United States and the associated monetary benefits total 268 million. Human health impacts and associated monetary value due to pollution removal was observed to be significantly high in urban areas indicating that grasslands and shrublands are equally critical as canopy in improving air quality and human health in urban regions.

  11. Equipment for the handling of thorium materials

    International Nuclear Information System (INIS)

    Heisler, S.W. Jr.; Mihalovich, G.S.

    1988-01-01

    The Feed Materials Production Center (FMPC) is the United States Department of Energy's storage facility for thorium. FMPC thorium handling and overpacking projects ensure the continued safe handling and storage of the thorium inventory until final disposition of the materials is determined and implemented. The handling and overpacking of the thorium materials requires the design of a system that utilizes remote handling and overpacking equipment not currently utilized at the FMPC in the handling of uranium materials. The use of remote equipment significantly reduces radiation exposure to personnel during the handling and overpacking efforts. The design system combines existing technologies from the nuclear industry, the materials processing and handling industry and the mining industry. The designed system consists of a modified fork lift truck for the transport of thorium containers, automated equipment for material identification and inventory control, and remote handling and overpacking equipment for material identification and inventory control, and remote handling and overpacking equipment for repackaging of the thorium materials

  12. Responding To Changes in the Decommissioning Plans for Demolition of a Former Active Handling Building at The United Kingdom Atomic Energy Establishment Winfrith

    International Nuclear Information System (INIS)

    Brown, N.; Parkinson, S.J.; Cornell, R.M.; Staples, A.T.

    2006-01-01

    The full decommissioning of the former Active Handling Building A59 at Winfrith in Dorset is being carried out by RWE NUKEM Limited under contract from the site owners and nuclear site licence holder, United Kingdom Atomic Energy Authority (UKAEA). Following recent government changes, the United Kingdom's Nuclear Decommissioning Authority (NDA) has now set up contracts with UKAEA for delivery of the site clean-up programme. The building contains two heavily shielded suites of caves originally used to carry out remote examination of irradiated nuclear fuel elements together with other supporting facilities. The original intention was to demolish the caves ahead of the building but after detailed consideration it was concluded that demolition of the building in advance of the caves was more operationally effective. As a result, the original decommissioning plan had to be reworked to reflect these changes. The paper briefly explains how this situation arose and the means by which the problems experienced were overcome by a complete revision to the decommissioning programme. The updated plan has been adopted by UKAEA and work is now proceeding apace to clear the building of redundant items, to complete decontamination of all remaining areas and facilities and to carry out detailed radiological surveys to confirm that the building structure is clean and ready for demolition. Both cave lines have been completely decontaminated to low residual levels of activity and are essentially ready for controlled demolition. This paper describes some of the significant tasks undertaken during the past year with particular reference to the decommissioning techniques that gave the greatest success and the limitations of others originally considered. Some of these processes were aimed at minimising the volume of low level waste (LLW) generated by using standard off-the-shelf equipment to remove contamination from ∼5 Ton concrete blocks recovered from both cave line structures. A

  13. Preliminary evaluation of the Community Multiscale Air Quality model for 2002 over the Southeastern United States.

    Science.gov (United States)

    Morris, Ralph E; McNally, Dennis E; Tesche, Thomas W; Tonnesen, Gail; Boylan, James W; Brewer, Patricia

    2005-11-01

    The Visibility Improvement State and Tribal Association of the Southeast (VISTAS) is one of five Regional Planning Organizations that is charged with the management of haze, visibility, and other regional air quality issues in the United States. The VISTAS Phase I work effort modeled three episodes (January 2002, July 1999, and July 2001) to identify the optimal model configuration(s) to be used for the 2002 annual modeling in Phase II. Using model configurations recommended in the Phase I analysis, 2002 annual meteorological (Mesoscale Meterological Model [MM5]), emissions (Sparse Matrix Operator Kernal Emissions [SMOKE]), and air quality (Community Multiscale Air Quality [CMAQ]) simulations were performed on a 36-km grid covering the continental United States and a 12-km grid covering the Eastern United States. Model estimates were then compared against observations. This paper presents the results of the preliminary CMAQ model performance evaluation for the initial 2002 annual base case simulation. Model performance is presented for the Eastern United States using speciated fine particle concentration and wet deposition measurements from several monitoring networks. Initial results indicate fairly good performance for sulfate with fractional bias values generally within +/-20%. Nitrate is overestimated in the winter by approximately +50% and underestimated in the summer by more than -100%. Organic carbon exhibits a large summer underestimation bias of approximately -100% with much improved performance seen in the winter with a bias near zero. Performance for elemental carbon is reasonable with fractional bias values within +/- 40%. Other fine particulate (soil) and coarse particular matter exhibit large (80-150%) overestimation in the winter but improved performance in the summer. The preliminary 2002 CMAQ runs identified several areas of enhancements to improve model performance, including revised temporal allocation factors for ammonia emissions to improve

  14. Uranium hexafluoride handling

    International Nuclear Information System (INIS)

    1991-01-01

    The United States Department of Energy, Oak Ridge Field Office, and Martin Marietta Energy Systems, Inc., are co-sponsoring this Second International Conference on Uranium Hexafluoride Handling. The conference is offered as a forum for the exchange of information and concepts regarding the technical and regulatory issues and the safety aspects which relate to the handling of uranium hexafluoride. Through the papers presented here, we attempt not only to share technological advances and lessons learned, but also to demonstrate that we are concerned about the health and safety of our workers and the public, and are good stewards of the environment in which we all work and live. These proceedings are a compilation of the work of many experts in that phase of world-wide industry which comprises the nuclear fuel cycle. Their experience spans the entire range over which uranium hexafluoride is involved in the fuel cycle, from the production of UF 6 from the naturally-occurring oxide to its re-conversion to oxide for reactor fuels. The papers furnish insights into the chemical, physical, and nuclear properties of uranium hexafluoride as they influence its transport, storage, and the design and operation of plant-scale facilities for production, processing, and conversion to oxide. The papers demonstrate, in an industry often cited for its excellent safety record, continuing efforts to further improve safety in all areas of handling uranium hexafluoride

  15. Uranium hexafluoride handling. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    1991-12-31

    The United States Department of Energy, Oak Ridge Field Office, and Martin Marietta Energy Systems, Inc., are co-sponsoring this Second International Conference on Uranium Hexafluoride Handling. The conference is offered as a forum for the exchange of information and concepts regarding the technical and regulatory issues and the safety aspects which relate to the handling of uranium hexafluoride. Through the papers presented here, we attempt not only to share technological advances and lessons learned, but also to demonstrate that we are concerned about the health and safety of our workers and the public, and are good stewards of the environment in which we all work and live. These proceedings are a compilation of the work of many experts in that phase of world-wide industry which comprises the nuclear fuel cycle. Their experience spans the entire range over which uranium hexafluoride is involved in the fuel cycle, from the production of UF{sub 6} from the naturally-occurring oxide to its re-conversion to oxide for reactor fuels. The papers furnish insights into the chemical, physical, and nuclear properties of uranium hexafluoride as they influence its transport, storage, and the design and operation of plant-scale facilities for production, processing, and conversion to oxide. The papers demonstrate, in an industry often cited for its excellent safety record, continuing efforts to further improve safety in all areas of handling uranium hexafluoride. Selected papers were processed separately for inclusion in the Energy Science and Technology Database.

  16. Emissions from oil and gas operations in the United States and their air quality implications.

    Science.gov (United States)

    Allen, David T

    2016-06-01

    The energy supply infrastructure in the United States has been changing dramatically over the past decade. Increased production of oil and natural gas, particularly from shale resources using horizontal drilling and hydraulic fracturing, made the United States the world's largest producer of oil and natural gas in 2014. This review examines air quality impacts, specifically, changes in greenhouse gas, criteria air pollutant, and air toxics emissions from oil and gas production activities that are a result of these changes in energy supplies and use. National emission inventories indicate that volatile organic compound (VOC) and nitrogen oxide (NOx) emissions from oil and gas supply chains in the United States have been increasing significantly, whereas emission inventories for greenhouse gases have seen slight declines over the past decade. These emission inventories are based on counts of equipment and operational activities (activity factors), multiplied by average emission factors, and therefore are subject to uncertainties in these factors. Although uncertainties associated with activity data and missing emission source types can be significant, multiple recent measurement studies indicate that the greatest uncertainties are associated with emission factors. In many source categories, small groups of devices or sites, referred to as super-emitters, contribute a large fraction of emissions. When super-emitters are accounted for, multiple measurement approaches, at multiple scales, produce similar results for estimated emissions. Challenges moving forward include identifying super-emitters and reducing their emission magnitudes. Work done to date suggests that both equipment malfunction and operational practices can be important. Finally, although most of this review focuses on emissions from energy supply infrastructures, the regional air quality implications of some coupled energy production and use scenarios are examined. These case studies suggest that both

  17. Thermal-economic optimization of an air-cooled heat exchanger unit

    International Nuclear Information System (INIS)

    Alinia Kashani, Amir Hesam; Maddahi, Alireza; Hajabdollahi, Hassan

    2013-01-01

    Thermodynamic modeling and optimal design of an air-cooled heat exchanger (ACHE) unit are developed in this study. For this purpose, ε–NTU method and mathematical relations are applied to estimate the fluids outlet temperatures and pressure drops in tube and air sides. The main goal of this study is minimizing of two conflicting objective functions namely the temperature approach and the minimum total annual cost, simultaneously. For this purpose, fast and elitist non-dominated sorting genetic-algorithm (NSGA-II) is applied to minimize the objective functions by considering ten design parameters. In addition, a set of typical constraints, governing on the ACHE unit design, is subjected to obtain more practical optimum design points. Furthermore, sensitivity analysis of change in the objective functions, when the optimum design parameters vary, is conducted and the degree of each parameter on conflicting objective functions has been investigated. Finally, a selection procedure of the best optimum point is introduced and final optimum design point is determined. -- Highlights: ► Multi-objective optimization of air-cooled heat exchanger. ► Considering ten new design parameters in this type of heat exchanger. ► A detailed cost function is used to estimate the heat exchanger investment cost. ► Presenting a mathematical relation for optimum total cost vs. temperature approach. ► The sensitivity analysis of parameters in the optimum situation

  18. Health and cost impact of air pollution from biomass burning over the United States

    Science.gov (United States)

    Eslami, E.; Sadeghi, B.; Choi, Y.

    2017-12-01

    Effective assessment of health and cost effects of air pollution associated with wildfire events is critical for supporting sustainable management and policy analysis to reduce environmental damages. Since biomass burning events result in higher ozone, PM2.5, and NOx concentration values in urban regions due to long-range transport, preliminary results indicated that wildfire events cause a considerable increase in incident estimates and costs. This study aims to evaluate the health and cost impact of biomass burning events over the continental United States using combined air quality and health impact modeling. To meet this goal, a comprehensive air quality modeling scenarios containing biomass burning emissions were conducted using the Community Multiscale Air Quality (CMAQ) modeling system from 2011 to 2014 with a spatial resolution of 12 km. The modeling period includes fire seasons between April and October over the course of four years. By using modeled pollutants concentrations, the USEPA's GIS-based computer program Environmental Benefits Mapping and Analysis Program-Community Edition (BenMAP-CE) provides an inclusive figure of health and cost impact caused by changing gaseous and particulate air pollution due to fire events. The basis of BenMAP-CE is the use of a damage-function approach to estimate the health impact of an applied change in air quality by comparing a biomass burning scenario (the one that includes wildfire events) with a baseline scenario (without biomass emissions). This approach considers several factors containing population, exposure to the pollutants, adverse health effects of a particular pollutant, and economic costs. Hence, this study made it capable of showing how biomass burning across U.S. influences people's health in different months, seasons, and regions. Besides, the cost impact of the wildfire events during study periods has also been estimated at both national and regional levels. The results of this study demonstrate the

  19. An Analysis of the United States-Led Coalition Air Campaign Conducted During the 1991 War with IRAQ: Desert Storm

    National Research Council Canada - National Science Library

    Murphy, John

    2002-01-01

    Evaluation of the 1991 United States led coalition Persian Gulf War (DESERT STORM) Air Campaign is performed to measure its adherence to basic principles of war and to determine the potential implications for the future conduct of war...

  20. Optimum placement of condensing units of split-type air-conditioners by numerical simulation

    Energy Technology Data Exchange (ETDEWEB)

    Avara, Abdollah; Daneshgar, Ehsan [Mechanical Engineering Department, Persian Gulf University, Bushehr (Iran, Islamic Republic of)

    2008-07-01

    Split-type air-conditioners used in residential or office buildings often have the outdoor condensing units installed at the sidewalls or on the roofs. Installation distance from the supporting wall for the first group and the height of installation for the second group are two factors that affect the condenser efficiency. In this study, a CFD code is used to calculate the effect of distance from the supporting wall on the entrance air temperature and on the on-coil temperature of condenser installed between two walls. In the case of condenser installed on the roof, the effect of installation height of the condenser from the finished roof on on-coil temperature is investigated and the minimum recommended height of installation is determined. (author)

  1. Air pollution response to changing weather and power plant emissions in the eastern United States

    Science.gov (United States)

    Bloomer, Bryan Jaye

    Air pollution in the eastern United States causes human sickness and death as well as damage to crops and materials. NOX emission reduction is observed to improve air quality. Effectively reducing pollution in the future requires understanding the connections between smog, precursor emissions, weather, and climate change. Numerical models predict global warming will exacerbate smog over the next 50 years. My analysis of 21 years of CASTNET observations quantifies a climate change penalty. I calculate, for data collected prior to 2002, a climate penalty factor of ˜3.3 ppb O3/°C across the power plant dominated receptor regions in the rural, eastern U.S. Recent reductions in NOX emissions decreased the climate penalty factor to ˜2.2 ppb O3/°C. Prior to 1995, power plant emissions of CO2, SO2, and NOX were estimated with fuel sampling and analysis methods. Currently, emissions are measured with continuous monitoring equipment (CEMS) installed directly in stacks. My comparison of the two methods show CO 2 and SO2 emissions are ˜5% lower when inferred from fuel sampling; greater differences are found for NOX emissions. CEMS are the method of choice for emission inventories and commodity trading and should be the standard against which other methods are evaluated for global greenhouse gas trading policies. I used CEMS data and applied chemistry transport modeling to evaluate improvements in air quality observed by aircraft during the North American electrical blackout of 2003. An air quality model produced substantial reductions in O3, but not as much as observed. The study highlights weaknesses in the model as commonly used for evaluating a single day event and suggests areas for further investigation. A new analysis and visualization method quantifies local-daily to hemispheric-seasonal scale relationships between weather and air pollution, confirming improved air quality despite increasing temperatures across the eastern U.S. Climate penalty factors indicate

  2. Interactive effects of air pollution and climate change on forest ecosystems in the United States: current understanding and future scenarios

    Science.gov (United States)

    Andrzej Bytnerowicz; Mark Fenn; Steven McNulty; Fengming Yuan; Afshin Pourmokhtarian; Charles Driscoll; Tom Meixner

    2013-01-01

    A review of the current status of air pollution and climate change (CC) in the United States from a perspective of their impacts on forest ecosystems is provided. Ambient ozone (O3) and nitrogen (N) deposition have important and widespread ecological impacts in U.S. forests. Effects of sulphurous (S) air pollutants and other trace pollutants have...

  3. Significantly Reduced Health Burden from Ambient Air Pollution in the United States under Emission Reductions from 1990 to 2016

    Science.gov (United States)

    The 2015 Global Burden of Disease (GBD) study has listed air pollution as the fourth-ranking global mortality risk factor. Few studies have attempted to understand how these burdens change through time, especially in the United States (US). Here we aim to estimate air pollution-r...

  4. Analisis dan Rencana Pengembangan Jaringan Distribusi Air Bersih Unit Cabang Timur PDAM Kabupaten Klaten

    Directory of Open Access Journals (Sweden)

    Ana Tri Lestari

    2017-01-01

    Full Text Available Unit Cabang Timur Perusahaan Daerah Air Minum (PDAM Kabupaten Klaten dibagi menjadi 3 unit pelayanan Ibu Kota Kecamatan (IKK dan mempunyai tingkat pelayanan yang masih rendah pada tahun 2015, yaitu Unit IKK Ceper 17,6%; Unit IKK Pedan 2,43%; dan Unit IKK Cawas 31,26% sehingga peningkatan persen pelayanan menjadi hal yang perlu dilakukan. Hal ini didukung dengan adanya penambahan debit produksi sebesar 50 liter/detik. Selain itu, jaringan distibusi belum dibentuk blok pelayanan sehingga sulit untuk mengontrol kehilangan air. Perencanaan ini dilakukan pembagian blok pelayanan menjadi 26 blok dan 5 tapping. Setelah itu dilakukan analisis kondisi eksiting. Hasil analisis kondisi eksisting menunjukkan kondisi hidrolika perpipaan kecuali kecepatan masih memenuhi kriteria, yaitu tekanan antara (15,43-59,99 m, kecepatan (0-0,91 m/detik, unit headloss (0-3,51 m/km. Kemudian dilakukan pengembangan jaringan yang dibagi menjadi 2 tahap, dimana tahap 1 meningkatkan persen pelayanan, sedangkan tahap 2 menambah daerah pelayanan baru. Blok pelayanan setelah pengembangan menjadi 29 blok dan 5 titik tapping. Kemudian analisis rencana pengembangan dilakukan dan menunjukkan bahwa kondisi hidrolika pipa untuk tekanan di jaringan distribusi IKK Cawas bernilai negatif. Hal ini dikarenakan unit headloss yang terjadi pada pipa dari reservoir menuju titik tapping pertama IKK Cawas sebesar 5,78 m/km dengan panjang pipa 14,35 km sehingga headloss  sebesar 82,94 m menyebabkan tekanan menjadi -2,89 m. Permasalahan ini dapat diatasi dengan parallel pipa diameter 200 mm sepanjang 9 km. Parallel pipa tersebut mengakibatkan tekanan  pada titik tapping pertama IKK Cawas menjadi 34,65 m dan titik tapping terjauh (blok 19 sebesar 16,34 m.  Hasil analisis hidrolika, seperti unit headloss berada pada rentang (0-5,78 m/km, namun kecepatan masih ada yang di bawah 0,3 m/detik. Rencana anggaran biaya (RAB yang dibutuhkan untuk melakukan pengembangan jaringan sebesar Rp 2.470.153,051.71.

  5. High Electricity Demand in the Northeast U.S.: PJM Reliability Network and Peaking Unit Impacts on Air Quality.

    Science.gov (United States)

    Farkas, Caroline M; Moeller, Michael D; Felder, Frank A; Henderson, Barron H; Carlton, Annmarie G

    2016-08-02

    On high electricity demand days, when air quality is often poor, regional transmission organizations (RTOs), such as PJM Interconnection, ensure reliability of the grid by employing peak-use electric generating units (EGUs). These "peaking units" are exempt from some federal and state air quality rules. We identify RTO assignment and peaking unit classification for EGUs in the Eastern U.S. and estimate air quality for four emission scenarios with the Community Multiscale Air Quality (CMAQ) model during the July 2006 heat wave. Further, we population-weight ambient values as a surrogate for potential population exposure. Emissions from electricity reliability networks negatively impact air quality in their own region and in neighboring geographic areas. Monitored and controlled PJM peaking units are generally located in economically depressed areas and can contribute up to 87% of hourly maximum PM2.5 mass locally. Potential population exposure to peaking unit PM2.5 mass is highest in the model domain's most populated cities. Average daily temperature and national gross domestic product steer peaking unit heat input. Air quality planning that capitalizes on a priori knowledge of local electricity demand and economics may provide a more holistic approach to protect human health within the context of growing energy needs in a changing world.

  6. Learning Styles of Pilots Currently Qualified in United States Air Force Aircraft

    Science.gov (United States)

    Kanske, Craig A.

    2001-01-01

    Kolb's Learning Style Inventory was used to identify the predominant learning styles of pilots currently qualified in United States Air Force aircraft. The results indicate that these pilots show a significant preference for facts and things over people and feelings. By understanding the preferred learning styles of the target population, course material can be developed that take advantage of the strengths of these learning styles. This information can be especially useful in the future design of cockpit resource management training. The training program can be developed to demonstrate both that there are different learning styles and that it is possible to take advantage of the relative strengths of each of these learning styles.

  7. Safety of Cargo Aircraft Handling Procedure

    Directory of Open Access Journals (Sweden)

    Daniel Hlavatý

    2017-07-01

    Full Text Available The aim of this paper is to get acquainted with the ways how to improve the safety management system during cargo aircraft handling. The first chapter is dedicated to general information about air cargo transportation. This includes the history or types of cargo aircraft handling, but also the means of handling. The second part is focused on detailed description of cargo aircraft handling, including a description of activities that are performed before and after handling. The following part of this paper covers a theoretical interpretation of safety, safety indicators and legislative provisions related to the safety of cargo aircraft handling. The fourth part of this paper analyzes the fault trees of events which might occur during handling. The factors found by this analysis are compared with safety reports of FedEx. Based on the comparison, there is a proposal on how to improve the safety management in this transportation company.

  8. Climate Change and Health Risks from Extreme Heat and Air Pollution in the Eastern United States

    Science.gov (United States)

    Limaye, V.; Vargo, J.; Harkey, M.; Holloway, T.; Meier, P.; Patz, J.

    2013-12-01

    Climate change is expected to exacerbate health risks from exposure to extreme heat and air pollution through both direct and indirect mechanisms. Directly, warmer ambient temperatures promote biogenic emissions of ozone precursors and favor the formation of ground-level ozone, while an anticipated increase in the frequency of stagnant air masses will allow fine particulates to accumulate. Indirectly, warmer summertime temperatures stimulate energy demand and exacerbate polluting emissions from the electricity sector. Thus, while technological adaptations such as air conditioning can reduce risks from exposures to extreme heat, they can trigger downstream damage to air quality and public health. Through an interdisciplinary modeling effort, we quantify the impacts of climate change on ambient temperatures, summer energy demand, air quality, and public health. The first phase of this work explores how climate change will directly impact the burden of heat-related mortality. Climatic patterns, demographic trends, and epidemiologic risk models suggest that populations in the eastern United States are likely to experience an increasing heat stress mortality burden in response to rising summertime air temperatures. We use North American Regional Climate Change Assessment Program modeling data to estimate mid-century 2-meter air temperatures and humidity across the eastern US from June-August, and quantify how long-term changes in actual and apparent temperatures from present-day will affect the annual burden of heat-related mortality across this region. With the US Environmental Protection Agency's Environmental Benefits Mapping and Analysis Program, we estimate health risks using concentration-response functions, which relate temperature increases to changes in annual mortality rates. We compare mid-century summertime temperature data, downscaled using the Weather Research and Forecasting model, to 2007 baseline temperatures at a 12 km resolution in order to estimate

  9. Surgically Shaping a Financial Hydra: Reprogramming United States Air Force End Strength to the Air Reserve Component

    Science.gov (United States)

    2012-02-14

    Director of the Air National Guard20 Lt Gen Charles E. Stenner Jr., Chief of the Air Force Reserve21 Specificity about what rebalancing the force...January 2012). Sharp, Travis. Vision Meets Reality: 2010 QDR and 2011 Defense Budget. Center for a New American Security, February 2010. Stenner ...Lt Gen Charles E. Stenner Jr., commander of Air Force Reserve Command (address, Air Force Reserve Senior Leader Conference

  10. [The balance of harmful trace contaminants between the air humidity condensate and air in a simulator of the Mir orbit station moisture condensation unit].

    Science.gov (United States)

    Zlotopol'skiĭ, V M; Smolenskaia, T S

    2000-01-01

    Subject of the investigation was the balance of harmful trace contaminants (HTC) between the air moisture condensate and air in a simulator of the MIR moisture condensation unit. Experiments involved various classes of water-solvent compounds including alcohols (C1-C4), ketons (C1-C2), aldehydes (C1-C2), fatty acids (C2-C4), esters (acetates C4-C6), and ammonium. For most of the compounds, removal efficiency correlates with air humidity and virtually does not depend on the HTC concentration within the range of 0.25 to 59.1 mg/m3.

  11. Air Quality and Respiratory Health among Adolescents from the United Arab Emirates

    Directory of Open Access Journals (Sweden)

    Caroline Barakat-Haddad

    2015-01-01

    Full Text Available Purpose. To examine the role of air quality in relation to chronic bronchitis, emphysema, asthma, wheeze, and dry cough among adolescents from the United Arab Emirates (UAE. Methods. A survey was administered on 6,363 adolescents from 9 UAE regions. Data consists of demographic, socioeconomic, residential, and behavioural variables, such as location of residence, residing near industry/gas stations/dumpsites/construction sites, residing near overhead power line/plants, exposure to tobacco, residential exposure, ethnicity, concern over air pollution, smoking, and purposely smelling gasoline fumes/glue/correctors/car exhaust/burning black ants. Logistic regression modeling was used to determine significant predictors of respiratory health. Results. Asthma prevalence was 12.3%, followed by chronic bronchitis (1.8% and emphysema (0.5%. Overall 12.2% reported wheeze and 34.8% reported a dry nocturnal cough in the past year. Multivariate analyses suggest that sex is a significant predictor of asthma and dry cough. Exposure to tobacco and arts/crafts/ceramics/stain is significant predictor of respiratory health. Tobacco smoking and purposely smelling gasoline fumes/glue/correctors/car exhaust/burning black ants are significant predictors of wheeze and dry cough. Conclusions. This study suggests that exposure to air quality and behavioral factors such as smoking and purposely smelling gasoline fumes, glue, correctors, car exhaust, or burning black ants are significant predictors of respiratory health among UAE adolescents.

  12. Scale-Free Networks and Commercial Air Carrier Transportation in the United States

    Science.gov (United States)

    Conway, Sheila R.

    2004-01-01

    Network science, or the art of describing system structure, may be useful for the analysis and control of large, complex systems. For example, networks exhibiting scale-free structure have been found to be particularly well suited to deal with environmental uncertainty and large demand growth. The National Airspace System may be, at least in part, a scalable network. In fact, the hub-and-spoke structure of the commercial segment of the NAS is an often-cited example of an existing scale-free network After reviewing the nature and attributes of scale-free networks, this assertion is put to the test: is commercial air carrier transportation in the United States well explained by this model? If so, are the positive attributes of these networks, e.g. those of efficiency, flexibility and robustness, fully realized, or could we effect substantial improvement? This paper first outlines attributes of various network types, then looks more closely at the common carrier air transportation network from perspectives of the traveler, the airlines, and Air Traffic Control (ATC). Network models are applied within each paradigm, including discussion of implied strengths and weaknesses of each model. Finally, known limitations of scalable networks are discussed. With an eye towards NAS operations, utilizing the strengths and avoiding the weaknesses of scale-free networks are addressed.

  13. Lagrangian particle modeling of air pollution transport in southwestern United States

    Energy Technology Data Exchange (ETDEWEB)

    Uliasz, M. [Warsaw Univ. of Technology (Poland); Stocker, R.A.; Pielke, R.A. [Colorado State Univ., Fort Collins, CO (United States)

    1994-12-31

    Several modeling techniques of various complexity and accuracy are applied in a numerical modeling study of regional air pollution transport being performed within the Measurement Of Haze And Visual Effect (MOHAVE) project. The goal of this study is to assess the impact of the Mohave Power Project (MPP) and other potential sources of air pollution to specific Class I areas located in the desert southwest United States including the Grand Canyon National Park. The Colorado State University team is performing the daily meteorological and dispersion simulations for a year long study using a nonhydrostatic mesoscale meteorological model; the Regional Atmospheric Modeling System (RAMS) coupled with a Lagrangian particle dispersion (LPD) model. The modeling domain covers the southwestern United States with its extremely complex terrain. Two complementary dispersion modeling techniques: a traditional source-oriented approach and receptor-oriented approach are used to calculate concentration and influence function fields, respectively. All computations are performed on two IBM RISC-6000 workstations dedicated to the project. The goal of this paper is to present our design for daily dispersion simulations with an emphasis on influence function calculations using examples from the winter and summer intensive periods of the MOHAVE project.

  14. Energy Savings and Economics of Advanced Control Strategies for Packaged Air-Conditioning Units with Gas Heat

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Weimin; Katipamula, Srinivas; Huang, Yunzhi; Brambley, Michael R.

    2011-12-31

    Pacific Northwest National Laboratory (PNNL) with funding from the U.S. Department of Energy's Building Technologies Program (BTP) evaluated a number of control strategies that can be implemented in a controller, to improve the operational efficiency of the packaged air conditioning units. The two primary objectives of this research project are: (1) determine the magnitude of energy savings achievable by retrofitting existing packaged air conditioning units with advanced control strategies not ordinarily used for packaged units and (2) estimating what the installed cost of a replacement control with the desired features should be in various regions of the U.S. This document reports results of the study.

  15. Effectiveness of heating, ventilation and air conditioning system with HEPA filter unit on indoor air quality and asthmatic children's health

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Ying; Raja, Suresh; Ferro, Andrea R.; Jaques, Peter A.; Hopke, Philip K. [Clarkson University, 8 Clarkson Avenue, Center for Air Resources Engineering and Science, Potsdam, NY 13699 (United States); Gressani, Cheryl; Wetzel, Larry E. [Air Innovations, Inc, 7000 Performance Drive, North Syracuse, NY 13212 (United States)

    2010-02-15

    Poor indoor air quality has been linked to the exacerbation of asthma symptoms in children. Because people spend most of their time indoors, improving indoor air quality may provide some relief to asthma sufferers. A study was conducted to assess whether operating an air cleaning/ventilating unit (HEPAiRx {sup registered}) in a child's bedroom can improve his/her respiratory health. Thirty children diagnosed with asthma were randomly split into two groups. For the first six weeks, group A had the air cleaning/ventilating unit (HEPAiRx {sup registered}) running in the bedrooms of the participants and group B did not; for the second six weeks, both groups had the cleaners running in the bedrooms; and, for the final six weeks, group A turned the cleaners off and group B kept theirs running. Indoor air quality parameters, including temperature, relative humidity, particulate matter (PM 0.5-10 {mu}m), carbon monoxide, carbon dioxide and total volatile organic compound (TVOC) concentrations, were monitored in each bedroom using an AirAdvice indoor air quality multi-meter. As a measure of pulmonary inflammation, exhaled breath condensate (EBC) was collected every sixth day and analyzed for nitrate and pH. Peak expiratory flow (PEF) was also measured. PM and TVOC concentrations decreased with operation of the HEPAiRx an average of 72% and 59%, respectively. The EBC nitrate concentrations decreased significantly and the EBC pH and PEF values increased significantly with operation of the unit (p < 0.001 when comparing on/off sample means). These results indicate that air cleaning in combination with ventilation can effectively reduce symptoms for asthma sufferers. (author)

  16. Relationship between the merit factor of thermoelectric materials and the air conditioning unit of urban electric cars

    International Nuclear Information System (INIS)

    Buffet, J.

    1994-01-01

    The main benefit of electric cars is to reduce air pollution in cities that is thus desirable to equip them with non polluting air conditioning units and this rules out frigorific compressors operating with CFC. The planned replacement of CFC by HFC is at best an interim solution. The best solution is certainly to use thermoelectric air conditioning units, which are inherently pollution-free. However, these have a fairly low COPF when compared to traditional compressor units. We study the relationship between the cooling of the interior of urban electric cars and the merit factor of the thermoelectric material in their Peltier unit. This should help provide concrete target properties of future T E materials. copyright 1995 American Institute of Physics

  17. Analytical solutions for evaluating the thermal performances of wet air cooling coils under both unit and non-unit Lewis Factors

    International Nuclear Information System (INIS)

    Xia Liang; Chan, M.Y.; Deng, S.M.; Xu, X.G.

    2010-01-01

    Analytical solutions for evaluating the thermal performances of both chilled water wet cooling coils and direct expansion (DX) wet cooling coils, respectively, under both unit and non-unit Lewis Factors are developed and reported in this paper. The analytical solution was validated by comparing its predictions with those from numerically solving the fundamental governing equations of heat and mass transfer taking place in a wet cooling coil. With the analytical solutions, the distributions of air temperature and humidity ratio along air flow direction in a wet cooling coil can be predicted, and the differences in the thermal performances of the cooling coils under both unit and non-unit Lewis Factors can be identified. The analytical solutions, on one hand, can be a low-cost replacement to numerically solving the fundamental heat and mass transfer governing equations, and on the other hand, is able to deal with evaluating thermal performance for wet air cooling coils operated under both unit and non-unit Lewis Factors.

  18. Confinement facilities for handling plutonium

    International Nuclear Information System (INIS)

    Maraman, W.J.; McNeese, W.D.; Stafford, R.G.

    1975-01-01

    Plutonium handling on a multigram scale began in 1944. Early criteria, equipment, and techniques for confining contamination have been superseded by more stringent criteria and vastly improved equipment and techniques for in-process contamination control, effluent air cleaning and treatment of liquid wastes. This paper describes the evolution of equipment and practices to minimize exposure of workers and escape of contamination into work areas and into the environment. Early and current contamination controls are compared. (author)

  19. Remote handling in ZEPHYR

    International Nuclear Information System (INIS)

    Andelfinger, C.; Lackner, E.; Ulrich, M.; Weber, G.; Schilling, H.B.

    1982-04-01

    A conceptual design of the ZEPHYR building is described. The listed radiation data show that remote handling devices will be necessary in most areas of the building. For difficult repair and maintenance works it is intended to transfer complete units from the experimental hall to a hot cell which provides better working conditions. The necessary crane systems and other transport means are summarized as well as suitable commercially available manipulators and observation devices. The conept of automatic devices for cutting and welding and other operations inside the vacuum vessel and the belonging position control system is sketched. Guidelines for the design of passive components are set up in order to facilitate remote operation. (orig.)

  20. Handling hunger strikers.

    Science.gov (United States)

    1992-04-01

    Hunger strikes are being used increasingly and not only by those with a political point to make. Whereas in the past, hunger strikes in the United Kingdom seemed mainly to be started by terrorist prisoners for political purposes, the most recent was begun by a Tamil convicted of murder, to protest his innocence. In the later stages of his strike, before calling it off, he was looked after at the Hammersmith Hospital. So it is not only prison doctors who need to know how to handle a hunger strike. The following guidelines, adopted by the 43rd World Medical Assembly in Malta in November 1991, are therefore a timely reminder of the doctor's duties during a hunger strike.

  1. Potential air quality benefits from increased solar photovoltaic electricity generation in the Eastern United States

    Energy Technology Data Exchange (ETDEWEB)

    Abel, David; Holloway, Tracey; Harkey, Monica; Rrushaj, Arber; Brinkman, Greg; Duran, Phillip; Janssen, Mark; Denholm, Paul

    2018-02-01

    We evaluate how fine particulate matter (PM2.5) and precursor emissions could be reduced if 17% of electricity generation was replaced with solar photovoltaics (PV) in the Eastern United States. Electricity generation is simulated using GridView, then used to scale electricity-sector emissions of sulfur dioxide (SO2) and nitrogen oxides (NOX) from an existing gridded inventory of air emissions. This approach offers a novel method to leverage advanced electricity simulations with state-of-the-art emissions inventories, without necessitating recalculation of emissions for each facility. The baseline and perturbed emissions are input to the Community Multiscale Air Quality Model (CMAQ version 4.7.1) for a full accounting of time- and space-varying air quality changes associated with the 17% PV scenario. These results offer a high-value opportunity to evaluate the reduced-form AVoided Emissions and geneRation Tool (AVERT), while using AVERT to test the sensitivity of results to changing base-years and levels of solar integration. We find that average NOX and SO2 emissions across the region decrease 20% and 15%, respectively. PM2.5 concentrations decreased on average 4.7% across the Eastern U.S., with nitrate (NO3-) PM2.5 decreasing 3.7% and sulfate (SO42-) PM2.5 decreasing 9.1%. In the five largest cities in the region, we find that the most polluted days show the most significant PM2.5 decrease under the 17% PV generation scenario, and that the greatest benefits are accrued to cities in or near the Ohio River Valley. We find summer health benefits from reduced PM2.5 exposure estimated as 1424 avoided premature deaths (95% Confidence Interval (CI): 284 deaths, 2 732 deaths) or a health savings of $13.1 billion (95% CI: $0.6 billion, $43.9 billion) These results highlight the potential for renewable energy as a tool for air quality managers to support current and future health-based air quality regulations.

  2. Potential air quality benefits from increased solar photovoltaic electricity generation in the Eastern United States

    Science.gov (United States)

    Abel, David; Holloway, Tracey; Harkey, Monica; Rrushaj, Arber; Brinkman, Greg; Duran, Phillip; Janssen, Mark; Denholm, Paul

    2018-02-01

    We evaluate how fine particulate matter (PM2.5) and precursor emissions could be reduced if 17% of electricity generation was replaced with solar photovoltaics (PV) in the Eastern United States. Electricity generation is simulated using GridView, then used to scale electricity-sector emissions of sulfur dioxide (SO2) and nitrogen oxides (NOX) from an existing gridded inventory of air emissions. This approach offers a novel method to leverage advanced electricity simulations with state-of-the-art emissions inventories, without necessitating recalculation of emissions for each facility. The baseline and perturbed emissions are input to the Community Multiscale Air Quality Model (CMAQ version 4.7.1) for a full accounting of time- and space-varying air quality changes associated with the 17% PV scenario. These results offer a high-value opportunity to evaluate the reduced-form AVoided Emissions and geneRation Tool (AVERT), while using AVERT to test the sensitivity of results to changing base-years and levels of solar integration. We find that average NOX and SO2 emissions across the region decrease 20% and 15%, respectively. PM2.5 concentrations decreased on average 4.7% across the Eastern U.S., with nitrate (NO3-) PM2.5 decreasing 3.7% and sulfate (SO42-) PM2.5 decreasing 9.1%. In the five largest cities in the region, we find that the most polluted days show the most significant PM2.5 decrease under the 17% PV generation scenario, and that the greatest benefits are accrued to cities in or near the Ohio River Valley. We find summer health benefits from reduced PM2.5 exposure estimated as 1424 avoided premature deaths (95% Confidence Interval (CI): 284 deaths, 2 732 deaths) or a health savings of 13.1 billion (95% CI: 0.6 billion, 43.9 billion) These results highlight the potential for renewable energy as a tool for air quality managers to support current and future health-based air quality regulations.

  3. Eielson Air Force Base operable unit 2 and other areas record of decision

    International Nuclear Information System (INIS)

    Lewis, R.E.; Smith, R.M.

    1994-10-01

    This decision document presents the selected remedial actions and no action decisions for Operable Unit 2 (OU2) at Eielson Air Force Base (AFB), Alaska, chosen in accordance with state and federal regulations. This document also presents the decision that no further action is required for 21 other source areas at Eielson AFB. This decision is based on the administrative record file for this site. OU2 addresses sites contaminated by leaks and spills of fuels. Soils contaminated with petroleum products occur at or near the source of contamination. Contaminated subsurface soil and groundwater occur in plumes on the top of a shallow groundwater table that fluctuates seasonally. These sites pose a risk to human health and the environment because of ingestion, inhalation, and dermal contact with contaminated groundwater. The purpose of this response is to prevent current or future exposure to the contaminated groundwater, to reduce further contaminant migration into the groundwater, and to remediate groundwater

  4. An analysis of post-traumatic stress symptoms in United States Air Force drone operators.

    Science.gov (United States)

    Chappelle, Wayne; Goodman, Tanya; Reardon, Laura; Thompson, William

    2014-06-01

    Remotely piloted aircraft (RPA), commonly referred to as "drones," have emerged over the past decade as an innovative warfighting tool. Given there is a paucity of empirical research assessing drone operators, the purpose of this study was to assess for the prevalence of PTSD symptoms among this cohort. Of the 1084 United States Air Force (USAF) drone operators that participated, a total of 4.3% endorsed a pattern of symptoms of moderate to extreme level of severity meeting criteria outlined in the Diagnostic and Statistical Manual of Mental Disorders-4th edition. The incidence of PTSD among USAF drone operators in this study was lower than rates of PTSD (10-18%) among military personnel returning from deployment but higher than incidence rates (less than 1%) of USAF drone operators reported in electronic medical records. Although low PTSD rates may be promising, limitations to this study are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Air pollution control in the United States: a mixed portfolio approach

    International Nuclear Information System (INIS)

    Kete, N.

    1994-01-01

    Much has been made of the experiments with emissions trading and other forms of incentive-based regulation in the United States. This chapter takes a step back to outline the principal program elements of the Clean Air Act, and then looks retrospectively at some of the issues that have arisen during the past two decades of debate on the role of emissions trading. It then goes on to differentiate that experience from new incentive-based programs created or authorized by the 1990 amendments, especially the acid rain control program. In considering the qualities of the acid rain program, or any other regulatory regime, the administrative structure cannot be separated from the primary objectives. The qualities that support a functional emission trading regime do not inhere in using incentive-based regulation. They result from self-conscious, transparent decisions to build such qualities into whatever program is chosen. 11 refs

  6. Air quality impacts of distributed energy resources implemented in the northeastern United States.

    Science.gov (United States)

    Carreras-Sospedra, Marc; Dabdub, Donald; Brouwer, Jacob; Knipping, Eladio; Kumar, Naresh; Darrow, Ken; Hampson, Anne; Hedman, Bruce

    2008-07-01

    Emissions from the potential installation of distributed energy resources (DER) in the place of current utility-scale power generators have been introduced into an emissions inventory of the northeastern United States. A methodology for predicting future market penetration of DER that considers economics and emission factors was used to estimate the most likely implementation of DER. The methodology results in spatially and temporally resolved emission profiles of criteria pollutants that are subsequently introduced into a detailed atmospheric chemistry and transport model of the region. The DER technology determined by the methodology includes 62% reciprocating engines, 34% gas turbines, and 4% fuel cells and other emerging technologies. The introduction of DER leads to retirement of 2625 MW of existing power plants for which emissions are removed from the inventory. The air quality model predicts maximum differences in air pollutant concentrations that are located downwind from the central power plants that were removed from the domain. Maximum decreases in hourly peak ozone concentrations due to DER use are 10 ppb and are located over the state of New Jersey. Maximum decreases in 24-hr average fine particulate matter (PM2.5) concentrations reach 3 microg/m3 and are located off the coast of New Jersey and New York. The main contribution to decreased PM2.5 is the reduction of sulfate levels due to significant reductions in direct emissions of sulfur oxides (SO(x)) from the DER compared with the central power plants removed. The scenario presented here represents an accelerated DER penetration case with aggressive emission reductions due to removal of highly emitting power plants. Such scenario provides an upper bound for air quality benefits of DER implementation scenarios.

  7. Operable Unit 1 remedial investigation report, Eielson Air Force Base, Alaska

    International Nuclear Information System (INIS)

    Gilmore, T.J.; Fruland, R.M.; Liikala, T.L.

    1994-06-01

    This remedial investigation report for operable Unit 1 (OU-1) at Eielson Air Force Base presents data, calculations, and conclusions as to the nature and extent of surface and subsurface contamination at the eight source areas that make up OU-1. The information is based on the 1993 field investigation result and previous investigations. This report is the first in a set of three for OU-1. The other reports are the baseline risk assessment and feasibility study. The information in these reports will lead to a Record of Decision that will guide and conclude the environmental restoration effort for OU-1 at Eielson Air Force Base. The primary contaminants of concern include fuels and fuel-related contaminants (diesel; benzene, toluene, ethylbenzene, and xylene; total petroleum hydrocarbon; polycyclic aromatic hydrocarbons), maintenance-related solvents and cleaners (volatile chlorinated hydrocarbons such as trichloroothylene), polychlorinated biphenyls, and dichlorodiphenyltrichloroethane (DDT). The origins of contaminants of concern include leaks from storage tanks, drums and piping, and spills. Ongoing operations and past sitewide practices also contribute to contaminants of concern at OU-1 source areas. These include spraying mixed oil and solvent wastes on unpaved roads and aerial spraying of DDT

  8. STUDI POTENSI PEMBANGKIT LISTRIK MINIHYDRO SISTEM TRANSMISI AIR BAKU PDAB UNIT BREGAS

    Directory of Open Access Journals (Sweden)

    Arya Rezagama

    2016-03-01

    Full Text Available Distribusi pelayanan listrik di Indonesia hingga kini masih belum merata. Banyak desa-desa di pegunungan yang masih terbatas dalam mengakses pasokan listrik. Salah satu alternatif solusinya ialah dengan memanfaatkan beda ketinggian sistem perpipaan transmisi air baku. Jaringan transmisi PDAB Tirta Utama Jateng Unit Bregas teridiri atas tiga jalur perpipaan meliputi jalur Eksisting, Bregas I, dan Bregas II memiliki 34 Bak Pelepas Tekan yang bisa ditanamkan Pembangkit Listrik Minihydro. Survei lapangan dilakukan dari mata air hingga lokasi Reservoir Yamansari menggunakan GPS. Pengukuran debit aliran pipa menggunakan alat Ultrasonik Flowmeter. Analisis hidrolika perpipaan dihitung dengan formula Hazen-Williams. Alternatif lokasi terbaik yang akan dimanfaatkan potensinya sebagai pembangkit listrik tenaga mikrohidro/minihidro adalah ruas perpipaan BPT III A – BPT III B pada jalur Bregas I dengan potensi daya yang dihasilkan 434,24 kW, kemudian ruas perpipaan Chamber Kalibakung – BPT III A pada jalur Bregas I dengan potensi daya yang dihasilkan 303,71 kW. Kondisi jalur Bergas II masih belum optimal dimana debit yang beroperasi sekarang hanya 150 l/det dapat ditingkatkan menjadi 250 l/det. Ruas perpipaan BPT 6 – BPT 7 pada jalur Bregas II dengan potensi daya yang dihasilkan 227 kW. Sedangkan sistem Bergas Eksisting tidak direkomendasikan untuk PLTM karena kondisi pipa yang sudah buruk dan kehandalan debit yang kurang baik dari sumbernya.

  9. Adrenaline and triiodothyronine modify the iron handling in the freshwater air-breathing fish Anabas testudineus Bloch: role of ferric reductase in iron acquisition.

    Science.gov (United States)

    Rejitha, V; Peter, M C Subhash

    2013-01-15

    , has a vital role in Fe(II) and Fe(III) iron handling in this fish. Our data also provide evidence that adrenaline, T(3) and the feeding status are the vital factors that can regulate the storage and handling of iron in fish. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Ambient sound levels at four Department of Interior conservation units in support of Homestead Air Base reuse supplemental environmental impact statement

    Science.gov (United States)

    1999-06-01

    The Federal Aviation Administration (FAA), in cooperation with the United States Air Force (USAF), is developing a Supplemental Environmental Impact Statement (SEIS) in support of the planned commercialization of Homestead Air Base in Southern Florid...

  11. Thermal and economical optimization of air conditioning units with vapor compression refrigeration system

    Energy Technology Data Exchange (ETDEWEB)

    Sanaye, S.; Malekmohammadi, H.R. [Iran University of Science and Technology, Tehran (Iran). Dept. of Mechanical Engineering

    2004-09-01

    A new method of thermal and economical optimum design of air conditioning units with vapor compression refrigeration system, is presented. Such a system includes compressor, condenser, evaporator, centrifugal and axial fans. Evaporator and condenser temperatures, their heating surface areas (frontal surface area and number of tubes), centrifugal and axial fan powers, and compressor power are among the design variables. The data provided by manufacturers for fan (volume flow rate versus pressure drop) and compressor power (using evaporator and condenser temperatures) was used to choose these components directly from available data for consumers. To study the performance of the system under various situations, and implementing the optimization procedure, a simulation program including all thermal and geometrical parameters was developed. The objective function for optimization was the total cost per unit cooling load of the system including capital investment for components as well as the required electricity cost. To find the system design parameters, this objective function was minimized by Lagrange multipliers method. The effects of changing the cooling load on optimal design parameters were studied. (author)

  12. Ant-nest corrosion of copper tubing in air-conditioning units

    Directory of Open Access Journals (Sweden)

    Bastidas, D. M.

    2006-10-01

    Full Text Available Ant-nest corrosion is a specific type of premature failure (2-3 months of copper tubes used in air-conditioning units causing the loss of refrigerant liquid and the consequent environment pollution. It is known that attack requires the simultaneous presence of moisture, oxygen and a corrodent, usually an organic acid, such as formic, acetic, propionic or butyric acid or other volatile organic substances like methanol, ethanol, formaldehyde or acetoaldehyde. Approximately 10% of all premature failures of copper tubes used in the heating, ventilation and air-conditioning (HVAC industry are the result of ant-nest corrosion. This type of corrosion usually occurs in thin-wall copper pipes, especially when copper is de-sulphurised, and is known by several names: formicary corrosion, unusual corrosion, branched pits, pinhole corrosion, etc.

    Corrosión por “nido de hormigas” es un tipo específico de fallo prematuro (2-3 meses que tiene lugar en tubos de cobre utilizados en sistemas de aire acondicionado originando la pérdida de líquido refrigerante y la consecuente contaminación ambiental. Es conocido que este tipo de ataque requiere la presencia simultánea de humedad, oxígeno y un medio agresivo, habitualmente un ácido orgánico, como fórmico, acético  propiónico o butírico u otras sustancias orgánicas volátiles tales como metanol, etanol, formaldehido o acetoaldehido. Aproximadamente el 10% de los fallos prematuros en tubos de cobre utilizados en calefacción, ventilación y en la industria de aire acondicionado son el resultado de corrosión por nido de hormigas. Frecuentemente, este tipo de corrosión tiene lugar en tubos de cobre de pared delgada, especialmente cuando el cobre es del tipo desulfurizado, y se conoce con varios nombres: corrosión por ácido fórmico, corrosión no habitual, picaduras ramificadas, corrosión con forma de alfiler, etc.

  13. Defense Infrastructure: Realignment of Air Force Special Operations Command Units to Cannon Air Force Base, New Mexico

    National Research Council Canada - National Science Library

    Lepore, Brian J

    2008-01-01

    .... As a result, Cannon Air Force Base will remain open. While DOD has satisfied the intent of the recommendation by finding a new mission for the base, this BRAC recommendation was unusual because it contained a contingency clause...

  14. United States Air Force Research Initiation Program. 1984 Research Reports. Volume 3.

    Science.gov (United States)

    1986-05-01

    right terminal of lamp 13. Position the second switch below switch A such that the handle may be pulled toward you or pushed away from you. The second...position. 42. Pull the handle of s.itch B toward you to light lamp B. 47. Fush.the handle of switch B all the way forward to light both lamps A and B... goalI was to obtain information that could lead to the stabilization of a . Nd:YAG laser. III. APPROACH At the beginning of this research, some of the

  15. Effects of Automobile Emissions on Air Pollution in the United States

    Science.gov (United States)

    Cohen, Ryan; Singh, Ramesh

    2016-07-01

    Currently, about more than 253,000,000 automobiles and trucks, some are new, old, gas and electric, ply on the roads in the United States of America. Around the world, human activities and energy demand are the main sources for the air pollution and ozone depletion, causing dense haze, fog and smog especially during winter season in the country like China and India and also observed in different parts of the world. In recent years, automakers have been pushed by new governmental regulations and global expectations to create more fuel-efficient vehicles that burn less fossil fuels and create fewer harmful emissions. Automakers are exploring alternative fuel options such as hydrogen, natural gas, hybrids, and completely electric vehicles. Since the Nissan Leaf's introduction in 2010, fully electric vehicles have become widely produced and just fewer than 400,000 fully electric cars have been sold in the United States. Taking the influx of more fuel-efficient and alternative energy vehicles in the market into account, we have analyzed satellite and ground observed atmospheric pollution and greenhouse gases during 2009-2014 in the United States of America. Our results show that the increasing population of hybrid and fuel efficient vehicles have cut down the atmospheric pollution and greenhouse emissions in US in general, whereas in California the pollution level has increased as a result frequency of fog and haze events are seen during winter season. We will present a comparison of atmospheric pollution over US and California State in view of the increasing hybrid and fuel efficient vehicles.

  16. AUTOMOTIVE DIESEL MAINTENANCE 1. UNIT II, MAINTAINING THE AIR SYSTEM--DETROIT DIESEL ENGINES.

    Science.gov (United States)

    Human Engineering Inst., Cleveland, OH.

    THIS MODULE OF A 30-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE OPERATION AND MAINTENANCE OF THE DIESEL ENGINE AIR SYSTEM. TOPICS ARE (1) OPERATION AND FUNCTION, (2) AIR CLEANER, (3) AIR SHUT-DOWN HOUSING, (4) EXHAUST SYSTEM, (5) BLOWER, (6) TURBOCHARGER, AND (7) TROUBLE-SHOOTING TIPS ON THE AIR SYSTEM. THE MODULE CONSISTS OF A…

  17. 48 CFR 47.403-2 - Air transport agreements between the United States and foreign governments.

    Science.gov (United States)

    2010-10-01

    ... Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT TRANSPORTATION Air Transportation by U.S... attend, the use of a foreign-flag air carrier that provides transportation under an air transport... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Air transport agreements...

  18. Management and Oversight of Services Acquisition Within the United States Air Force

    Science.gov (United States)

    2008-12-01

    Air Mobility Command AFDW Air Force District of Washington AFSPC Air Force Space Command AT&L Acquisition Technologies and Logistics CPM ...were commonly performed in industry. The types of services included advertising for Navy recruitment, custodial services on Air Force bases, and on

  19. NATO’s Relevance to United States Enduring National Interests Time to Remove the Training Wheels but Continue to Hold the Handle Bars

    Science.gov (United States)

    2016-06-10

    advice, and friendship will have a lasting and positive effect on not only my military career but also my professional & personal life after the Army...if NATO didn’t exist today, the United States would not seek to create it.”1 Magnus Petersson flrnher asserts that within the United States...this topic relevant to the current and emerging strategic environment.7 Magnus Petersson, The US-NATO Debate: From Libya to Ukraine. (New York

  20. NATOs Relevance to United States Enduring National Interests Time to Remove the Training Wheels but Continue to Hold the Handle Bars

    Science.gov (United States)

    2016-06-10

    advice, and friendship will have a lasting and positive effect on not only my military career but also my professional & personal life after the Army...if NATO didn’t exist today, the United States would not seek to create it.”1 Magnus Petersson flrnher asserts that within the United States...this topic relevant to the current and emerging strategic environment.7 Magnus Petersson, The US-NATO Debate: From Libya to Ukraine. (New York

  1. Research on Leadership, Motivation and Quality of Life in the Air Force Missile and Tanker Units

    Science.gov (United States)

    1977-06-01

    studying directly the results of applying different management principles in leading organizations. Enlight - ened management had demonstrated In... technologies for handling individual differences are fairly simple and straightforward. The demands placed upon analyses involving relationships and

  2. Handling of views and opinions by staters and others in a public hearing on alteration in reactor installation (addition of Unit 2) in the Sendai Nuclear Power Station of Kyushu Electric Power Co., Inc

    International Nuclear Information System (INIS)

    1981-01-01

    A public hearing on the addition of Unit 2 in the Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc., was held on July 17, 1980, in Sendai City, Kagoshima Prefecture. The views and opinions by the local staters and those by the notification of statement were expressed concerning its nuclear safety. The handling of these views and opinions by the Nuclear Safety Commission is explained. The most important in this action is the instruction by the NSC to the Committee on Examination of Reactor Safety to reflect the results of the public hearing to the reactor safety examination of the Unit 2 installation by the CERS. The views and opinions expressed in this connection are summarized as follows: the sitting conditions, the safety design of the reactor plant, and the release of radioactive materials, involving such aspects as earthquakes, accidents and radioactive waste management. (J.P.N.)

  3. A COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF AIR FLOW THROUGH A TELECOM BACK-UP UNIT POWERED BY AN AIR-COOLED PROTON EXCHANGE MEMBRANE FUEL CELL

    DEFF Research Database (Denmark)

    Gao, Xin; Berning, Torsten; Kær, Søren Knudsen

    2016-01-01

    Proton exchange membrane fuel cells (PEMFC’s) are currently being commercialized for various applications ranging from automotive to stationary such as powering telecom back-up units. In PEMFC’s, oxygen from air is internally combined with hydrogen to form water and produce electricity and heat....... This product heat has to be effectively removed from the fuel cell, and while automotive fuel cells are usually liquid-cooled using a secondary coolant loop similar to the internal combustion engines, stationary fuel cell systems as they are used for telecom back-up applications often rely on excessive air fed...... to the fuel cell cathode to remove the heat. Thereby, the fuel cell system is much simpler and cheaper while the fuel cell performance is substantially lower compared to automotive fuel cells. This work presents a computational fluid dynamics analysis on the heat management of an air-cooled fuel cell powered...

  4. Acanthamoeba belonging to T3, T4, and T11: genotypes isolated from air-conditioning units in Santiago, Chile.

    Science.gov (United States)

    Astorga, Berbeli; Lorenzo-Morales, Jacob; Martín-Navarro, Carmen M; Alarcón, Verónica; Moreno, Johanna; González, Ana C; Navarrete, Elizabeth; Piñero, José E; Valladares, Basilio

    2011-01-01

    Free-living amoebae (FLA) of the genus Acanthamoeba are widely distributed in the environment, in the air, soil, and water, and have also been isolated from air-conditioning units. The objective of this work was to investigate the presence of this genus of FLA in the air-conditioning equipment at the Institute of Public Health of Chile in Santiago, Chile. Water and air samples were collected from air-conditioning systems and were checked for the presence of Acanthamoeba spp. Positive samples were further classified at the genotype level after sequencing the highly variable diagnostic fragment 3 (DF3) region of the 18S rRNA gene. This is the first report of the T3, T4, and T11 genotypes of Acanthamoeba in air-conditioning units from Chile. Overall, the widespread distribution of potentially pathogenic Acanthamoeba strains in the studied source demands more awareness within the public and health professionals in Chile as this pathogen is emerging as a risk for human health worldwide. © 2011 The Author(s) Journal of Eukaryotic Microbiology © 2011 International Society of Protistologists.

  5. Biomass Burning Smoke Climatology of the United States: Implications for Particulate Matter Air Quality.

    Science.gov (United States)

    Kaulfus, Aaron S; Nair, Udaysankar; Jaffe, Daniel; Christopher, Sundar A; Goodrick, Scott

    2017-10-17

    We utilize the NOAA Hazard Mapping System smoke product for the period of 2005 to 2016 to develop climatology of smoke occurrence over the Continental United States (CONUS) region and to study the impact of wildland fires on particulate matter air quality at the surface. Our results indicate that smoke is most frequently found over the Great Plains and western states during the summer months. Other hotspots of smoke occurrence are found over state and national parks in the southeast during winter and spring, in the Gulf of Mexico southwards of the Texas and Louisiana coastline during spring season and along the Mississippi River Delta during the fall season. A substantial portion (20%) of the 24 h federal standard for particulate pollution exceedance events in the CONUS region occur when smoke is present. If the U.S. Environmental Protection Agency regulations continue to reduce anthropogenic emissions, wildland fire emissions will become the major contributor to particulate pollution and exceedance events. In this context, we show that HMS smoke product is a valuable tool for analysis of exceptional events caused by wildland fires and our results indicate that these tools can be valuable for policy and decision makers.

  6. An investigation of the air dispersion characteristics of refinery land treatment units

    International Nuclear Information System (INIS)

    Brewer, K.R.; Zaizhong Wang; Lupo, M.J.

    1991-01-01

    Numerical simulations of air emission and dispersion of volatile organic waste constituents from the land treatment units (LTU's) of four refineries were performed using the ISCST model. Particular attention was given to benzene. In order to realistically model the area pollutant source, each LTU had to be subdivided into smaller cells and the cell concentrations summed. The emission rate of the waste from the LTU's, one of the key inputs to the dispersion model, was periodically adjusted to reflect the rapid decay in rate following waste application. Meteorological conditions were found to be significant in determining boundary concentrations. The specific meteorological conditions most favorable for dispersion were investigated. The results of these simulations showed that mixing height is only minimally important in the dispersion of wastes from LTU's as currently regulated by EPA. Wind speed and variation of wind direction were both more important in atmospheric mixing of the volatile waste. It was found that care should be exercised in attempting to correlate any single meteorological parameter with favorable periods for land treatment. In comparisons of the cases, the results suggest that differences in LTU geometry may also be important in the modeling of long-term pollutant concentrations. Model simulations were performed to ascertain the impact of LTU geometry on boundary concentration

  7. National patterns in environmental injustice and inequality: outdoor NO2 air pollution in the United States.

    Science.gov (United States)

    Clark, Lara P; Millet, Dylan B; Marshall, Julian D

    2014-01-01

    We describe spatial patterns in environmental injustice and inequality for residential outdoor nitrogen dioxide (NO2) concentrations in the contiguous United States. Our approach employs Census demographic data and a recently published high-resolution dataset of outdoor NO2 concentrations. Nationally, population-weighted mean NO2 concentrations are 4.6 ppb (38%, p2.5 hours/week of physical activity). Inequality for NO2 concentration is greater than inequality for income (Atkinson Index: 0.11 versus 0.08). Low-income nonwhite young children and elderly people are disproportionately exposed to residential outdoor NO2. Our findings establish a national context for previous work that has documented air pollution environmental injustice and inequality within individual US metropolitan areas and regions. Results given here can aid policy-makers in identifying locations with high environmental injustice and inequality. For example, states with both high injustice and high inequality (top quintile) for outdoor residential NO2 include New York, Michigan, and Wisconsin.

  8. Greenhouse gas emissions for refrigerant choices in room air conditioner units.

    Science.gov (United States)

    Galka, Michael D; Lownsbury, James M; Blowers, Paul

    2012-12-04

    In this work, potential replacement refrigerants for window-mounted room air conditioners (RACs) in the U.S. have been evaluated using a greenhouse gas (GHG) emissions analysis. CO(2)-equivalent emissions for several hydrofluoroethers (HFEs) and other potential replacements were compared to the most widely used refrigerants today. Included in this comparison are pure refrigerants that make up a number of hydrofluorocarbon (HFC) mixtures, pure hydrocarbons, and historically used refrigerants such as propane and ammonia. GHG emissions from direct and indirect sources were considered in this thermodynamic analysis. Propylene, dimethyl ether, ammonia, R-152a, propane, and HFE-152a all performed effectively in a 1 ton window unit and produced slightly lower emissions than the currently used R-22 and R-134a. The results suggest that regulation of HFCs in this application would have some effect on reducing emissions since end-of-life emissions remain at 55% of total refrigerant charge despite EPA regulations that mandate 80% recovery. Even so, offsite emissions due to energy generation dominate over direct GHG emissions and all the refrigerants perform similarly in totals of indirect GHG emissions.

  9. National patterns in environmental injustice and inequality: outdoor NO2 air pollution in the United States.

    Directory of Open Access Journals (Sweden)

    Lara P Clark

    Full Text Available We describe spatial patterns in environmental injustice and inequality for residential outdoor nitrogen dioxide (NO2 concentrations in the contiguous United States. Our approach employs Census demographic data and a recently published high-resolution dataset of outdoor NO2 concentrations. Nationally, population-weighted mean NO2 concentrations are 4.6 ppb (38%, p2.5 hours/week of physical activity. Inequality for NO2 concentration is greater than inequality for income (Atkinson Index: 0.11 versus 0.08. Low-income nonwhite young children and elderly people are disproportionately exposed to residential outdoor NO2. Our findings establish a national context for previous work that has documented air pollution environmental injustice and inequality within individual US metropolitan areas and regions. Results given here can aid policy-makers in identifying locations with high environmental injustice and inequality. For example, states with both high injustice and high inequality (top quintile for outdoor residential NO2 include New York, Michigan, and Wisconsin.

  10. Energy-Efficient Supermarket Heating, Ventilation, and Air Conditioning in Humid Climates in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Clark, J. [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-03-01

    Supermarkets are energy-intensive buildings that consume the greatest amount of electricity per square foot of building of any building type in the United States and represent 5% of total U.S. commercial building primary energy use (EIA 2005). Refrigeration and heating, ventilation, and air-conditioning (HVAC) systems are responsible for a large proportion of supermarkets’ total energy use. These two systems sometimes work together and sometimes compete, but the performance of one system always affects the performance of the other. To better understand these challenges and opportunities, the Commercial Buildings team at the National Renewable Energy Laboratory investigated several of the most promising strategies for providing energy-efficient HVAC for supermarkets and quantified the resulting energy use and costs using detailed simulations. This research effort was conducted on behalf of the U.S. Department of Energy (DOE) Commercial Building Partnerships (CBP) (Baechler et al. 2012; Parrish et al. 2013; Antonopoulos et al. 2014; Hirsch et al. 2014). The goal of CBP was to reduce energy use in the commercial building sector by creating, testing, and validating design concepts on the pathway to net zero energy commercial buildings. Several CBP partners owned or operated buildings containing supermarkets and were interested in optimizing the energy efficiency of supermarket HVAC systems in hot-humid climates. These partners included Walmart, Target, Whole Foods Market, SUPERVALU, and the Defense Commissary Agency.

  11. Air quality impacts of increased use of ethanol under the United States’ Energy Independence and Security Act

    Science.gov (United States)

    Cook, Rich; Phillips, Sharon; Houyoux, Marc; Dolwick, Pat; Mason, Rich; Yanca, Catherine; Zawacki, Margaret; Davidson, Ken; Michaels, Harvey; Harvey, Craig; Somers, Joseph; Luecken, Deborah

    2011-12-01

    Increased use of ethanol in the United States fuel supply will impact emissions and ambient concentrations of greenhouse gases, "criteria" pollutants for which the U. S. EPA sets ambient air quality standards, and a variety of air toxic compounds. This paper focuses on impacts of increased ethanol use on ozone and air toxics under a potential implementation scenario resulting from mandates in the U. S. Energy Independence and Security Act (EISA) of 2007. The assessment of impacts was done for calendar year 2022, when 36 billion gallons of renewable fuels must be used. Impacts were assessed relative to a baseline which assumed ethanol volumes mandated by the first renewable fuels standard promulgated by U. S. EPA in early 2007. This assessment addresses both impacts of increased ethanol use on vehicle and other engine emissions, referred to as "downstream" emissions, and "upstream" impacts, i.e., those connected with fuel production and distribution. Air quality modeling was performed for the continental United States using the Community Multi-scale Air Quality Model (CMAQ), version 4.7. Pollutants included in the assessment were ozone, acetaldehyde, ethanol, formaldehyde, acrolein, benzene, and 1,3-butadiene. Results suggest that increased ethanol use due to EISA in 2022 will adversely increase ozone concentrations over much of the U.S., by as much as 1 ppb. However, EISA is projected to improve ozone air quality in a few highly-populated areas that currently have poor air quality. Most of the ozone improvements are due to our assumption of increases in nitrogen oxides (NO x) in volatile organic compound (VOC)-limited areas. While there are some localized impacts, the EISA renewable fuel standards have relatively little impact on national average ambient concentrations of most air toxics, although ethanol concentrations increase substantially. Significant uncertainties are associated with all results, due to limitations in available data. These uncertainties are

  12. CLIMATE CHANGE FUEL CELL PROGRAM UNITED STATES COAST GUARD AIR STATION CAPE COD BOURNE, MASSACHUSETTS

    Energy Technology Data Exchange (ETDEWEB)

    John K. Steckel Jr

    2004-06-30

    This report covers the first year of operation of a fuel cell power plant, installed by PPL Spectrum, Inc. (PPL) under contract with the United States Coast Guard (USCG), Research and Development Center (RDC). The fuel cell was installed at Air Station Cape Cod in Bourne, MA. The project had the support of the Massachusetts Technology Collaborative (MTC), the Department of Energy (DOE), and Keyspan Energy. PPL selected FuelCell Energy, Inc. (FCE) and its fuel cell model DFC{reg_sign}300 for the contract. Grant contributions were finalized and a contract between PPL and the USCG for the manufacture, installation, and first year's maintenance of the fuel cell was executed on September 24, 2001. As the prime contractor, PPL was responsible for all facets of the project. All the work was completed by PPL through various subcontracts, including the primary subcontract with FCE for the manufacture, delivery, and installation of the fuel cell. The manufacturing and design phases proceeded in a relatively timely manner for the first half of the project. However, during latter stages of manufacture and fuel cell testing, a variety of issues were encountered that ultimately resulted in several delivery delays, and a number of contract modifications. Final installation and field testing was completed in April and May 2003. Final acceptance of the fuel cell was completed on May 16, 2003. The fuel cell has operated successfully for more than one year. The unit achieved an availability rate of 96%, which exceeded expectations. The capacity factor was limited because the unit was set at 155 kW (versus a nameplate of 250 kW) due to the interconnection with the electric utility. There were 18 shutdowns during the first year and most were brief. The ability of this plant to operate in the island mode improved availability by 3 to 4%. Events that would normally be shutdowns were simply island mode events. The mean time between failure was calculated at 239 hours, or slightly

  13. Branding Icarus: The Construction of Identity and Diversity at The United States Air Force Academy

    Science.gov (United States)

    2015-06-01

    in the RAAF, Australia’s Sex Discrimina- tion Commissioner Elizabeth Broderick provided further insight into the construction of these five critical...Weber. 60 Unpublished statement by Elizabeth Broderick at Chief of Air Force New Horizon Call, RAAF... Broderick , Elizabeth. Unpublished Statement at Chief of Air Force New Horizon Call, Royal Australian Air Force Base Glenbrook, August 2013

  14. Comprehensive national database of tree effects on air quality and human health in the United States

    Science.gov (United States)

    Satoshi Hirabayashi; David J. Nowak

    2016-01-01

    Trees remove air pollutants through dry deposition processes depending upon forest structure, meteorology, and air quality that vary across space and time. Employing nationally available forest, weather, air pollution and human population data for 2010, computer simulations were performed for deciduous and evergreen trees with varying leaf area index for rural and...

  15. An Improved Calibration Method for Hydrazine Monitors for the United States Air Force

    Energy Technology Data Exchange (ETDEWEB)

    Korsah, K

    2003-07-07

    This report documents the results of Phase 1 of the ''Air Force Hydrazine Detector Characterization and Calibration Project''. A method for calibrating model MDA 7100 hydrazine detectors in the United States Air Force (AF) inventory has been developed. The calibration system consists of a Kintek 491 reference gas generation system, a humidifier/mixer system which combines the dry reference hydrazine gas with humidified diluent or carrier gas to generate the required humidified reference for calibrations, and a gas sampling interface. The Kintek reference gas generation system itself is periodically calibrated using an ORNL-constructed coulometric titration system to verify the hydrazine concentration of the sample atmosphere in the interface module. The Kintek reference gas is then used to calibrate the hydrazine monitors. Thus, coulometric titration is only used to periodically assess the performance of the Kintek reference gas generation system, and is not required for hydrazine monitor calibrations. One advantage of using coulometric titration for verifying the concentration of the reference gas is that it is a primary standard (if used for simple solutions), thereby guaranteeing, in principle, that measurements will be traceable to SI units (i.e., to the mole). The effect of humidity of the reference gas was characterized by using the results of concentrations determined by coulometric titration to develop a humidity correction graph for the Kintek 491 reference gas generation system. Using this calibration method, calibration uncertainty has been reduced by 50% compared to the current method used to calibrate hydrazine monitors in the Air Force inventory and calibration time has also been reduced by more than 20%. Significant findings from studies documented in this report are the following: (1) The Kintek 491 reference gas generation system (generator, humidifier and interface module) can be used to calibrate hydrazine detectors. (2) The

  16. Nuclear fuel handling apparatus

    International Nuclear Information System (INIS)

    Andrea, C.; Dupen, C.F.G.; Noyes, R.C.

    1977-01-01

    A fuel handling machine for a liquid metal cooled nuclear reactor in which a retractable handling tube and gripper are lowered into the reactor to withdraw a spent fuel assembly into the handling tube. The handling tube containing the fuel assembly immersed in liquid sodium is then withdrawn completely from the reactor into the outer barrel of the handling machine. The machine is then used to transport the spent fuel assembly directly to a remotely located decay tank. The fuel handling machine includes a decay heat removal system which continuously removes heat from the interior of the handling tube and which is capable of operating at its full cooling capacity at all times. The handling tube is supported in the machine from an articulated joint which enables it to readily align itself with the correct position in the core. An emergency sodium supply is carried directly by the machine to provide make up in the event of a loss of sodium from the handling tube during transport to the decay tank. 5 claims, 32 drawing figures

  17. Fuel handling machine and auxiliary systems for a fuel handling cell

    International Nuclear Information System (INIS)

    Suikki, M.

    2013-10-01

    This working report is an update for as well as a supplement to an earlier fuel handling machine design (Kukkola and Roennqvist 2006). A focus in the earlier design proposal was primarily on the selection of a mechanical structure and operating principle for the fuel handling machine. This report introduces not only a fuel handling machine design but also auxiliary fuel handling cell equipment and its operation. An objective of the design work was to verify the operating principles of and space allocations for fuel handling cell equipment. The fuel handling machine is a remote controlled apparatus capable of handling intensely radiating fuel assemblies in the fuel handling cell of an encapsulation plant. The fuel handling cell is air tight space radiation-shielded with massive concrete walls. The fuel handling machine is based on a bridge crane capable of traveling in the handling cell along wall tracks. The bridge crane has its carriage provided with a carousel type turntable having mounted thereon both fixed and telescopic masts. The fixed mast has a gripper movable on linear guides for the transfer of fuel assemblies. The telescopic mast has a manipulator arm capable of maneuvering equipment present in the fuel handling cell, as well as conducting necessary maintenance and cleaning operations or rectifying possible fault conditions. The auxiliary fuel handling cell systems consist of several subsystems. The subsystems include a service manipulator, a tool carrier for manipulators, a material hatch, assisting winches, a vacuum cleaner, as well as a hose reel. With the exception of the vacuum cleaner, the devices included in the fuel handling cell's auxiliary system are only used when the actual encapsulation process is not ongoing. The malfunctions of mechanisms or actuators responsible for the motion actions of a fuel handling machine preclude in a worst case scenario the bringing of the fuel handling cell and related systems to a condition appropriate for

  18. Fuel handling machine and auxiliary systems for a fuel handling cell

    Energy Technology Data Exchange (ETDEWEB)

    Suikki, M. [Optimik Oy, Turku (Finland)

    2013-10-15

    This working report is an update for as well as a supplement to an earlier fuel handling machine design (Kukkola and Roennqvist 2006). A focus in the earlier design proposal was primarily on the selection of a mechanical structure and operating principle for the fuel handling machine. This report introduces not only a fuel handling machine design but also auxiliary fuel handling cell equipment and its operation. An objective of the design work was to verify the operating principles of and space allocations for fuel handling cell equipment. The fuel handling machine is a remote controlled apparatus capable of handling intensely radiating fuel assemblies in the fuel handling cell of an encapsulation plant. The fuel handling cell is air tight space radiation-shielded with massive concrete walls. The fuel handling machine is based on a bridge crane capable of traveling in the handling cell along wall tracks. The bridge crane has its carriage provided with a carousel type turntable having mounted thereon both fixed and telescopic masts. The fixed mast has a gripper movable on linear guides for the transfer of fuel assemblies. The telescopic mast has a manipulator arm capable of maneuvering equipment present in the fuel handling cell, as well as conducting necessary maintenance and cleaning operations or rectifying possible fault conditions. The auxiliary fuel handling cell systems consist of several subsystems. The subsystems include a service manipulator, a tool carrier for manipulators, a material hatch, assisting winches, a vacuum cleaner, as well as a hose reel. With the exception of the vacuum cleaner, the devices included in the fuel handling cell's auxiliary system are only used when the actual encapsulation process is not ongoing. The malfunctions of mechanisms or actuators responsible for the motion actions of a fuel handling machine preclude in a worst case scenario the bringing of the fuel handling cell and related systems to a condition appropriate for

  19. Race, deprivation, and immigrant isolation: The spatial demography of air-toxic clusters in the continental United States.

    Science.gov (United States)

    Liévanos, Raoul S

    2015-11-01

    This article contributes to environmental inequality outcomes research on the spatial and demographic factors associated with cumulative air-toxic health risks at multiple geographic scales across the United States. It employs a rigorous spatial cluster analysis of census tract-level 2005 estimated lifetime cancer risk (LCR) of ambient air-toxic emissions from stationary (e.g., facility) and mobile (e.g., vehicular) sources to locate spatial clusters of air-toxic LCR risk in the continental United States. It then tests intersectional environmental inequality hypotheses on the predictors of tract presence in air-toxic LCR clusters with tract-level principal component factor measures of economic deprivation by race and immigrant status. Logistic regression analyses show that net of controls, isolated Latino immigrant-economic deprivation is the strongest positive demographic predictor of tract presence in air-toxic LCR clusters, followed by black-economic deprivation and isolated Asian/Pacific Islander immigrant-economic deprivation. Findings suggest scholarly and practical implications for future research, advocacy, and policy. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Analysis of chiller units capacity for different heat loads considering variation of ambient air and cooling water temperature

    International Nuclear Information System (INIS)

    Coman, Aurelia Camelia; Tenescu, Mircea

    2010-01-01

    The paper purpose is to analyze the chiller units capacity to determine whether they can cope with high air and cooling water temperatures during summer time to remove heat loads imposed from Heating, Ventilation and Air Conditioning (HVAC) units in a CANDU 6 Nuclear Power Plant. The starting point is calculation of the overall heat transfer coefficient at the evaporator and condenser. They are used in heat balance equations of heat exchangers. A mathematical model was developed that simulates the refrigeration cycle to assess the response of chilled water system and its performance at different heat loads. In this analysis there were calculated values for inlet/outlet chilled water temperature and the refrigerant cycle thermodynamic parameters (condenser and evaporator pressure/temperature, refrigerant mass flowrate, refrigerant quality at the evaporator, refrigerant vapour superheated temperature at the compressor outlet, refrigerant subcooled temperature at the condenser outlet). To find the adequate functioning parameters of the installation, the MathCAD 13 software was used in all cases analyzed. The behaviour of the chiller units was investigated by examining the variation of three basic parameters, namely: - cooling water (river water) temperature; - air temperature; - heat load. The simultaneous variation of these three independent parameters allows to identify the actual chillers unit operating point (including chiller trip). (authors)

  1. DISPOSAL CONTAINER HANDLING SYSTEM DESCRIPTION DOCUMENT

    Energy Technology Data Exchange (ETDEWEB)

    E. F. Loros

    2000-06-30

    by the WHB Ventilation System, which in conjunction with ventilation boundaries ensure that airborne radioactivity is confined by high efficiency particulate air filtration units. Electrical power is supplied by the Waste Handling Building Electrical System. The system also interfaces with each of the DC systems. New DCs are received from a commercial transport system.

  2. How to Handle Abuse

    Science.gov (United States)

    ... Handle Abuse KidsHealth / For Kids / How to Handle Abuse What's in this article? Tell Right Away How Do You Know Something Is Abuse? ... babysitter, teacher, coach, or a bigger kid. Child abuse can happen anywhere — at ... building. Tell Right Away A kid who is being seriously hurt ...

  3. Grain Handling and Storage.

    Science.gov (United States)

    Harris, Troy G.; Minor, John

    This text for a secondary- or postecondary-level course in grain handling and storage contains ten chapters. Chapter titles are (1) Introduction to Grain Handling and Storage, (2) Elevator Safety, (3) Grain Grading and Seed Identification, (4) Moisture Control, (5) Insect and Rodent Control, (6) Grain Inventory Control, (7) Elevator Maintenance,…

  4. The introduction of local air quality management in the United Kingdom: A review and theoretical framework

    Science.gov (United States)

    Longhurst, J. W. S.; Lindley, S. J.; Watson, A. F. R.; Conlan, D. E.

    In the light of recent episodes of poor air quality in many of the U.K.'s major urban areas, concern has been expressed regarding the apparent inability of existing air quality control procedures to effectively tackle contemporary scenarios. As a result of this, a new philosophy for air quality control has been sought which can provide a solid basis for the preservation and future improvement of air quality. It is proposed that a suitable mechanism for this would be found through the adoption of an integrated and holistic local air quality management approach. This paper will present and discuss a theoretical framework for the application of local air quality management in the U.K. and investigate the potential of the Environment Act (1995) to provide such a framework.

  5. 2017 INFORMS PRIZE. The Nomination of The United States Air Force

    Science.gov (United States)

    2017-02-08

    Member Lt Col Nicholas J. Zeisler Senior Operations Research Analyst, Headquarters Air Force (AF/A9RP) ROLE NAME ORGANIZATIONAL POSITION Publications...effective at detecting North Vietnamese trucks hidden under jungle canopy. Seventh Air Force Headquarters (top) Tan Son Nhut Air Base, Vietnam, 1962...1969 MACV Headquarters “Pentagon East” at Tan Son Nhut 432 0 17 I N F O R M S P R I Z E required the same kind of competent analysts, and applied the

  6. An Analysis of International Air Freight Forwarding Support for the United States Navy.

    Science.gov (United States)

    1985-06-01

    2. The Role of IATA in Ratemaking ... ...... 23 3. Current Environment ..... ........... 24 III. BURLINGTON-NORTHERN AIR FREIGHT, INCORPORATED . . 28...carrier is permitted access [Ref. 16]. 2. The Role of IATA in Ratemaking Factors other than shipper demand and carrier costs affect international freight...capability of the Air Force and Navy into one transport organization called the Military Air Transport Service (MATS). The mission of MATS was basically that

  7. Air Quality and Health Impacts of an Aviation Biofuel Supply Chain Using Forest Residue in the Northwestern United States.

    Science.gov (United States)

    Ravi, Vikram; Gao, Allan H; Martinkus, Natalie B; Wolcott, Michael P; Lamb, Brian K

    2018-04-03

    Forest residue is a major potential feedstock for second-generation biofuel; however, little knowledge exists about the environmental impacts of the development and production of biofuel from such a feedstock. Using a high-resolution regional air quality model, we estimate the air quality impacts of a forest residue based aviation biofuel supply chain scenario in the Pacific Northwestern United States. Using two potential supply chain regions, we find that biomass and biofuel hauling activities will add simulation. Using BenMAP, a health impact assessment tool, we show that avoiding slash pile burning results in a decrease in premature mortality as well as several other nonfatal and minor health effects. In general, we show that most air quality and health benefits result primarily from avoided slash pile burning emissions.

  8. Air

    International Nuclear Information System (INIS)

    Gugele, B.; Scheider, J.; Spangl, W.

    2001-01-01

    In recent years several regulations and standards for air quality and limits for air pollution were issued or are in preparation by the European Union, which have severe influence on the environmental monitoring and legislation in Austria. This chapter of the environmental control report of Austria gives an overview about the legal situation of air pollution control in the European Union and in specific the legal situation in Austria. It gives a comprehensive inventory of air pollution measurements for the whole area of Austria of total suspended particulates, ozone, volatile organic compounds, nitrogen oxides, sulfur dioxide, carbon monoxide, heavy metals, benzene, dioxin, polycyclic aromatic hydrocarbons and eutrophication. For each of these pollutants the measured emission values throughout Austria are given in tables and geographical charts, the environmental impact is discussed, statistical data and time series of the emission sources are given and legal regulations and measures for an effective environmental pollution control are discussed. In particular the impact of fossil-fuel power plants on the air pollution is analyzed. (a.n.)

  9. Symptoms of Psychological Distress and Post-Traumatic Stress Disorder in United States Air Force Drone Operators

    Science.gov (United States)

    2014-08-01

    Disorder in United States Air Force “ Drone ” Operators 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S...referred to as “ drones .” Participants were assessed for self-reported sources of occupational stress, levels of clinical distress using the Outcome...providers are discussed. 15. SUBJECT TERMS Stress, drone operator, PTSD, USAF 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT

  10. Effects of Sexual Harassment on Job Satisfaction, Retention, Cohesion, Commitment and Unit Effectiveness: The Case of the Air Force

    Science.gov (United States)

    2010-07-01

    quid pro quo ). Examples of questions that were used in previous studies to measure crude/offensive behavior, as well as, other forms of sexual ...includes, but is not limited to, harassment in which submission is made a condition of employment (or quid pro quo ). Global or organizational...Effects of Sexual Harassment on Job Satisfaction, Retention, Cohesion, Commitment and Unit Effectiveness: The Case of the Air Force Dr. Brenda

  11. Volatile Organic Compounds (VOCs) in the Ambient Air Of Concentration Unit of Sar-Cheshmeh Copper Complex

    International Nuclear Information System (INIS)

    Faghihi-Zrandi, A.; Akhgar, M. R.

    2016-01-01

    Air pollutants including gases, vapors and particles, are emitted from different sources. Volatile organic compounds are the most important pollutants in the ambient air of industries. The present study was carried out to identify and measurement of volatile organic compounds in concentration unit of Sar-Cheshmeh Copper Complex. In this study, sampling of the volatile organic compounds was done by using activated charcoal tube. To identify and measure these compounds gas chromatography/mass spectroscopy were used. Thirteen volatile organic compounds were identified in the ambient air of concentration unit. Among these compounds, the mean value and maximum concentration of isopropyl alcohol and nonane were 255, 640 μg/m3 and 1577, 14400 μg/m3, respectively. By using SPSS software and independent sample t- test, showed that there were no significant difference between mean value concentration of isopropyl alcohol and nonane in the ambient air and TLV values of these compounds (isopropyl alcohol; 200 ppm and nonane; 200 ppm) (P >0.05).

  12. Developing effective urban air quality management systems in the United Kingdom. Case studies

    Energy Technology Data Exchange (ETDEWEB)

    Elsom, D.M.; Crabbe, H. [Oxford Brookes Univ. (United Kingdom). Geography Unit

    1995-12-31

    During the past few years an increasing number of local authorities have expressed concern about the ambient levels of nitrogen dioxide, carbon monoxide, benzene and fine particulates that residents may be experiencing in traffic-congested parts of towns and cities. Although recent legislation is intended to reduce vehicle emissions (e.g. stricter exhaust emission standards requiring new cars to be equipped with catalytic converters), the growth in the number of motor vehicles, their frequency of use and the congestion they are causing in urban centres have resulted in little or no improvement in air quality. Although total vehicle emissions of nitrogen oxides, carbon monoxide and volatile organic compounds (VOCs) are expected to fall significantly during the next ten years, air quality will still remain a problem in some urban areas. Clearly, not all local air quality problems can be eliminated by the use of national legislation. For several years, local authorities and environmental organisations (e.g. National Society for Clean Air and Environmental Protection) have argued for local authorities to be given a statutory duty, together with appropriate funding from central government, to produce local air quality management plans which assess the seriousness of any air quality problems and which, if necessary, set out how poor air quality can be improved. This presentation examines the progress towards urban air quality management in the UK. (author)

  13. Control of exposure to exhaled air from sick occupant with wearable personal exhaust unit

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Melikov, Arsen Krikor; Barova, Maria I.

    2014-01-01

    of the doctor at three different distances. It was operated at 0.25 or 0.50 L/s under mixing background ventilation at 3 ACH. The use of wearable personal exhaust resulted in cleaner air in the room compared to mixing alone at 12 ACH. The high potential to capture exhaled air makes the device efficient against...

  14. Developing effective urban air quality management systems in the United Kingdom. Case studies

    Energy Technology Data Exchange (ETDEWEB)

    Elsom, D M; Crabbe, H [Oxford Brookes Univ. (United Kingdom). Geography Unit

    1996-12-31

    During the past few years an increasing number of local authorities have expressed concern about the ambient levels of nitrogen dioxide, carbon monoxide, benzene and fine particulates that residents may be experiencing in traffic-congested parts of towns and cities. Although recent legislation is intended to reduce vehicle emissions (e.g. stricter exhaust emission standards requiring new cars to be equipped with catalytic converters), the growth in the number of motor vehicles, their frequency of use and the congestion they are causing in urban centres have resulted in little or no improvement in air quality. Although total vehicle emissions of nitrogen oxides, carbon monoxide and volatile organic compounds (VOCs) are expected to fall significantly during the next ten years, air quality will still remain a problem in some urban areas. Clearly, not all local air quality problems can be eliminated by the use of national legislation. For several years, local authorities and environmental organisations (e.g. National Society for Clean Air and Environmental Protection) have argued for local authorities to be given a statutory duty, together with appropriate funding from central government, to produce local air quality management plans which assess the seriousness of any air quality problems and which, if necessary, set out how poor air quality can be improved. This presentation examines the progress towards urban air quality management in the UK. (author)

  15. United States Air Force Summer Faculty Research Program. 1985 Technical Report. Volume 2.

    Science.gov (United States)

    1985-12-01

    values decrease, and they are re-insertion sorted to make them less desirable as targets for entrepreneur processors, looking for market opportunities...where V Is the alsture denity o (p IP.)IT(y~t) d".rate of Increse of vapor air bass *rate at Whith front G, overruns water * air in virgin soil N

  16. Impacts of rising air temperatures on electric transmission ampacity and peak electricity load in the United States

    Science.gov (United States)

    Bartos, Matthew; Chester, Mikhail; Johnson, Nathan; Gorman, Brandon; Eisenberg, Daniel; Linkov, Igor; Bates, Matthew

    2016-11-01

    Climate change may constrain future electricity supply adequacy by reducing electric transmission capacity and increasing electricity demand. The carrying capacity of electric power cables decreases as ambient air temperatures rise; similarly, during the summer peak period, electricity loads typically increase with hotter air temperatures due to increased air conditioning usage. As atmospheric carbon concentrations increase, higher ambient air temperatures may strain power infrastructure by simultaneously reducing transmission capacity and increasing peak electricity load. We estimate the impacts of rising ambient air temperatures on electric transmission ampacity and peak per-capita electricity load for 121 planning areas in the United States using downscaled global climate model projections. Together, these planning areas account for roughly 80% of current peak summertime load. We estimate climate-attributable capacity reductions to transmission lines by constructing thermal models of representative conductors, then forcing these models with future temperature projections to determine the percent change in rated ampacity. Next, we assess the impact of climate change on electricity load by using historical relationships between ambient temperature and utility-scale summertime peak load to estimate the extent to which climate change will incur additional peak load increases. We find that by mid-century (2040-2060), increases in ambient air temperature may reduce average summertime transmission capacity by 1.9%-5.8% relative to the 1990-2010 reference period. At the same time, peak per-capita summertime loads may rise by 4.2%-15% on average due to increases in ambient air temperature. In the absence of energy efficiency gains, demand-side management programs and transmission infrastructure upgrades, these load increases have the potential to upset current assumptions about future electricity supply adequacy.

  17. The Impact of a Potential Shale Gas Development in Germany and the United Kingdom on Local and Regional Air Quality

    Science.gov (United States)

    Weger, L.; Lupascu, A.; Cremonese, L.; Butler, T. M.

    2017-12-01

    Numerous countries in Europe that possess domestic shale gas reserves are considering exploiting this unconventional gas resource as part of their energy transition agenda. While natural gas generates less CO2 emissions upon combustion compared to coal or oil, making it attractive as a bridge in the transition from fossil fuels to renewables, production of shale gas leads to emissions of CH4 and air pollutants such as NOx, VOCs and PM. These gases in turn influence the climate as well as air quality. In this study, we investigate the impact of a potential shale gas development in Germany and the United Kingdom on local and regional air quality. This work builds on our previous study in which we constructed emissions scenarios based on shale gas utilization in these counties. In order to explore the influence of shale gas production on air quality, we investigate emissions predicted from our shale gas scenarios with the Weather Research and Forecasting model with chemistry (WRF-Chem) model. In order to do this, we first design a model set-up over Europe and evaluate its performance for the meteorological and chemical parameters. Subsequently we add shale gas emissions fluxes based on the scenarios over the area of the grid in which the shale gas activities are predicted to occur. Finally, we model these emissions and analyze the impact on air quality on both a local and regional scale. The aims of this work are to predict the range of adverse effects on air quality, highlight the importance of emissions control strategies in reducing air pollution, to promote further discussion, and to provide policy makers with information for decision making on a potential shale gas development in the two study countries.

  18. The association between daily concentrations of air pollution and visits to a psychiatric emergency unit: a case-crossover study.

    Science.gov (United States)

    Oudin, Anna; Åström, Daniel Oudin; Asplund, Peter; Steingrimsson, Steinn; Szabo, Zoltan; Carlsen, Hanne Krage

    2018-01-10

    Air pollution is one of the leading causes of mortality and morbidity worldwide. Experimental studies, and a few epidemiological studies, suggest that air pollution may cause acute exacerbation of psychiatric disorders, and even increase the rate of suicide attempts, but epidemiological studies on air pollution in association with psychiatric disorders are still few. Our aim was to investigate associations between daily fluctuations in air pollution concentrations and the daily number of visits to a psychiatric emergency unit. Data from Sahlgrenska University Hospital, Gothenburg, Sweden, on the daily number of visits to the Psychiatric emergency unit were combined with daily data on monitored concentrations of respirable particulate matter(PM 10 ), ozone(O 3 ), nitrogen dioxides(NO 2 ) and temperature between 1st July 2012 and 31st December 2016. We used a case-crossover design to analyze data with conditional Poisson regression models allowing for over-dispersion. We stratified data on season. Visits increased with increasing PM 10 levels during the warmer season (April to September) in both single-pollutant and two-pollutant models. For example, an increase of 3.6% (95% Confidence Interval, CI, 0.4-7.0%) was observed with a 10 μg/m3 increase in PM 10 adjusted for NO 2 . In the three-pollutant models (adjusting for NO 2 and O 3 simultaneously) the increase was 3.3% (95% CI, -0.2-6.9). There were no clear associations between the outcome and NO 2 , O 3 , or PM 10 during the colder season (October to March). Ambient air particle concentrations were associated with the number of visits to the Psychiatric emergency unit in the warm season. The results were only borderline statistically significant in the fully adjusted (three-pollutant) models in this small study. The observation could be interpreted as indicative of air pollution as either exacerbating an underlying psychiatric disorder, or increasing mental distress, even in areas with comparatively low levels of

  19. Remote handling equipment

    International Nuclear Information System (INIS)

    Clement, G.

    1984-01-01

    After a definition of intervention, problems encountered for working in an adverse environment are briefly analyzed for development of various remote handling equipments. Some examples of existing equipments are given [fr

  20. United States Air Force Statistical Digest. Fiscal Year 1970. 25th Edition

    Science.gov (United States)

    1971-02-22

    GUIDED MISSILE. AIR TO AIR MISSILE. AND TARGET DRONEACCEPTANCES BY MANUFACTURER. BY MONTI -!- FY 1970 o ACCEPl’ED ACCEPTANCES FOR FY 1970 TOTAL...AUTOMATICALLY DECLASSIFIEDDOD VIR. 5200.10 CONFIDENTIAL Ceylon •••••.•.•..• 19 19 - 1 - 6 - 12 - - - - - Federation of Malaysia . • • • 215 215 67 17 1...Medical Service Squadrons & Flights • • • • • • • • Air Postal & Courier ,Groups& Fligl:ts ••••••• Censorship Squadrons

  1. Non-linear model predictive supervisory controller for building, air handling unit with recuperator and refrigeration system with heat waste recovery

    DEFF Research Database (Denmark)

    Minko, Tomasz; Wisniewski, Rafal; Bendtsen, Jan Dimon

    2016-01-01

    . The retrieved heat excess can be stored in the water tank. For this purpose the charging and the discharging water loops has been designed. We present the non-linear model of the above described system and a non-linear model predictive supervisory controller that according to the received price signal......, occupancy information and ambient temperature minimizes the operation cost of the whole system and distributes set points to local controllers of supermarkets subsystems. We find that when reliable information about the high price period is available, it is profitable to use the refrigeration system...... to generate heat during the low price period, store it and use it to substitute the conventional heater during the high price period....

  2. Benefit Analysis Report, United States Air Force Technical Order Management Systems (AFTOMS)

    Science.gov (United States)

    1989-08-01

    This report prepared by the Transportation Systems Center (TSC) concludes an analysis of the Technical Order (TO) costs and benefits, which was originally undertaken as part of the US Air Force Computer-aided Acquisition and Logistics Support (CALS) ...

  3. United States Air Force Precision Engagement Against Mobile Targets: Is Man In or Out

    National Research Council Canada - National Science Library

    Kosan, Keith

    2001-01-01

    ... been strategically placed by an adversary in areas with a high risk of collateral damage. Current air-to-ground guided weapon systems, including man-in-the-loop guidance weapon systems, have limited 'collateral reduction' capabilities...

  4. Portable air quality sensor unit for participatory monitoring: an end-to-end VESNA-AQ based prototype

    Science.gov (United States)

    Vucnik, Matevz; Robinson, Johanna; Smolnikar, Miha; Kocman, David; Horvat, Milena; Mohorcic, Mihael

    2015-04-01

    Key words: portable air quality sensor, CITI-SENSE, participatory monitoring, VESNA-AQ The emergence of low-cost easy to use portable air quality sensors units is opening new possibilities for individuals to assess their exposure to air pollutants at specific place and time, and share this information through the Internet connection. Such portable sensors units are being used in an ongoing citizen science project called CITI-SENSE, which enables citizens to measure and share the data. The project aims through creating citizens observatories' to empower citizens to contribute to and participate in environmental governance, enabling them to support and influence community and societal priorities as well as associated decision making. An air quality measurement system based on VESNA sensor platform was primarily designed within the project for the use as portable sensor unit in selected pilot cities (Belgrade, Ljubljana and Vienna) for monitoring outdoor exposure to pollutants. However, functionally the same unit with different set of sensors could be used for example as an indoor platform. The version designed for the pilot studies was equipped with the following sensors: NO2, O3, CO, temperature, relative humidity, pressure and accelerometer. The personal sensor unit is battery powered and housed in a plastic box. The VESNA-based air quality (AQ) monitoring system comprises the VESNA-AQ portable sensor unit, a smartphone app and the remote server. Personal sensor unit supports wireless connection to an Android smartphone via built-in Wi-Fi. The smartphone in turn serves also as the communication gateway towards the remote server using any of available data connections. Besides the gateway functionality the role of smartphone is to enrich data coming from the personal sensor unit with the GPS location, timestamps and user defined context. This, together with an accelerometer, enables the user to better estimate ones exposure in relation to physical activities, time

  5. Cleanth Brooks at the United States Air Force Academy April 11-12, 1978,

    Science.gov (United States)

    1980-01-01

    literature, particularly lyrical poetry and meditative poetry, would be taught as wholes. Q: When does teaching writing fit in? cB: Well, I think that...What an ear he has and how he can handle imagery. He has written some very beautiful lyrics . And so I could go on. My list would not be particularly...1963. pp. 37-8. 8. William Faulkner. The Yoknapatawpha Country (1963). 9. "The Poet & The City" in The Dyer’s Hand and Other Essays (London: Faber and

  6. Performance improvement of a hybrid air conditioning system using the indirect evaporative cooler with internal baffles as a pre-cooling unit

    Directory of Open Access Journals (Sweden)

    A.E. Kabeel

    2017-12-01

    Full Text Available In the present paper, the effects of the indirect evaporative cooler with internal baffle on the performance of the hybrid air conditioning system are numerically investigated. The hybrid air conditioning system contains two indirect evaporative coolers with internal baffle, one is utilized to pre-cool the air inlet to the desiccant wheel and the other is utilized to pre-cool the supply air inlet to the room. The effects of the inlet conditions of the process and reactivation air and working air ratio on the thermal performance of the hybrid air conditioning system have been analyzed. The results of this study show that in the hybrid air conditioning system for using the indirect evaporative cooler with internal baffle as a pre-cooling unit, the supply air temperature reduced by 21% and the coefficient of performance improved by 71% as compared to previous designs of the hybrid air conditioning system at the same inlet conditions. For increasing process air inlet temperature from 25 °C to 45 °C, supply air temperature increases from 12.7 °C to 14.2 °C, thermal COP increases from 1.87 to 2.84, and supply air relative humidity increases from 76.7% to 77.4%. Also, for increasing the reactivation air inlet temperature from 70 °C to 110 °C, supply air temperature dropped from 15.9 °C to 10.9 °C, supply air relative humidity dropped from 82.7% to 71.8%, and thermal COP dropped from 4.5 to 1.7. The recommended optimal air working ratio in the indirect evaporative cooler with internal baffle should be 0.15. Keywords: Desiccant material, Solar air collector, Evaporative cooler, Internal baffles, Air conditioning

  7. The US Air Force Aerial Spray Unit: a history of large area disease vector control operations, WWII through Katrina.

    Science.gov (United States)

    Breidenbaugh, Mark; Haagsma, Karl

    2008-01-01

    The US Air Force has had a long history of aerial applications of pesticides to fulfill a variety of missions, the most important being the protection of troops through the minimization of arthropod vectors capable of disease transmission. Beginning in World War II, aerial application of pesticides by the military has effectively controlled vector and nuisance pest populations in a variety of environments. Currently, the military aerial spray capability resides in the US Air Force Reserve (USAFR), which operates and maintains C-130 airplanes capable of a variety of missions, including ultra low volume applications for vector and nuisance pests, as well as higher volume aerial applications of herbicides and oil-spill dispersants. The USAFR aerial spray assets are the only such fixed-wing aerial spray assets within the Department of Defense. In addition to troop protection, the USAFR Aerial Spray Unit has participated in a number of humanitarian/relief missions, most recently in the response to the 2005 Hurricanes Katrina and Rita, which heavily damaged the Gulf Coasts of Louisiana, Mississippi, and Texas. This article provides historical background on the Air Force Aerial Spray Unit and describes the operations in Louisiana in the aftermath of Hurricane Katrina.

  8. Experimental and Numerical Study of the Radiant Induction-Unit and the Induction Radiant Air-Conditioning System

    Directory of Open Access Journals (Sweden)

    Qiang Si

    2016-12-01

    Full Text Available In this paper we proposed the novel air-conditioning system which combined induction ventilation and radiant air-conditioning. The indoor terminal device is the radiant induction-unit (RIDU. The RIDU is the induction unit combined with the pore radiant panel on which the copper pipes with rigid aluminum diffusion fins are installed. The two-stage evaporator chiller with the non-azeotropic mixture refrigerant is utilized in the system to reduce the initial investment in equipment. With the performance test and the steady state heat transfer model based on the theory of radiative heat transfer, the relationship between the induction ratio of the RIDU and the characteristic of the air supply was studied. Based on this, it is verified that the RIDU has a lower dew-point temperature and better anti-condensation performance than a traditional plate-type radiant panel. The characteristics of the radiation and convection heat transfer of the RIDU were studied. The total heat exchange of the RIDU can be 16.5% greater than that of the traditional plate-type radiant terminal.

  9. Status of environmental response efforts at radioactively contaminated sites in the united states air force installation restoration program

    International Nuclear Information System (INIS)

    Rowe, W.D. Jr.; McEntee, T.E. Jr.; Johnson, B.; Manning, L.

    1995-01-01

    The United States Air Force has identified approximately 170 radioactively contaminated sites at its domestic installations. These sites contain a variety of low level radioactive and mixed wastes and are classified as burial sites, landfills, buildings, and other disposal sites. Of these 170, approximately 70 are presently being evaluated under the Air Force Installation Restoration Program (IRP) in accordance with applicable laws and regulations. Removal and/or remedial actions have been taken at specific sites using site-specific residual radioactivity criteria. The remaining sites are either under investigation to determine the need for possible action or have been classified as response complete based on restricted or unrestricted future use. This paper describes past Air Force operations that generated radioactive waste materials; examines the current inventory of resulting radioactively contaminated sites in the Air Force IRP; reviews criteria used to evaluate sites for removal and/or remedial actions; provides summary information on actions taken at sites; and focuses on response actions and cleanup levels at two completed sites. The paper concludes with an assessment of outstanding issues relevant to the remediation of radioactively contaminated sites. (author)

  10. Experience of Data Handling with IPPM Payload

    Science.gov (United States)

    Errico, Walter; Tosi, Pietro; Ilstad, Jorgen; Jameux, David; Viviani, Riccardo; Collantoni, Daniele

    2010-08-01

    A simplified On-Board Data Handling system has been developed by CAEN AURELIA SPACE and ABSTRAQT as PUS-over-SpaceWire demonstration platform for the Onboard Payload Data Processing laboratory at ESTEC. The system is composed of three Leon2-based IPPM (Integrated Payload Processing Module) computers that play the roles of Instrument, Payload Data Handling Unit and Satellite Management Unit. Two PCs complete the test set-up simulating an external Memory Management Unit and the Ground Control Unit. Communication among units take place primarily through SpaceWire links; RMAP[2] protocol is used for configuration and housekeeping. A limited implementation of ECSS-E-70-41B Packet Utilisation Standard (PUS)[1] over CANbus and MIL-STD-1553B has been also realized. The Open Source RTEMS is running on the IPPM AT697E CPU as real-time operating system.

  11. United States Air Force Statistical Digest, Fiscal Year 1962, Seventeenth Edition

    Science.gov (United States)

    1962-09-30

    1,377 77 162 505 1,062 9 128 2. l53 1.090 hQ2Q12 298 531 249 2,459 ~50 1.587 302 75831 65 113201 ~ ,,2~3 ~ 12 392 580 279 2,6o~; 48 ~ 300 75885 75132222 92...2 6 MIUTARY AIR TRANSPORT SERVICE - TOTAL. .’ 942,269 13 1 g td 13 ! I 1 25 ~1st Quarter 223,571 3" I - - - - 2 I Ŗnd Quarter 232,692 2 1...Air Ccmnand 9 1 - - B 259 39,270 USAF Academy td 1 - - - 1 4 120 ill Air Forces in Europe. 45 1 - - 44 649 50,970 USAFSecurity Service, 5 - - - 5 214

  12. A Study of the Effects of Rank and Gender on Officers' Club Membership and Club Usage at U.S. Air Force Bases in the Continental United States

    National Research Council Canada - National Science Library

    Smith, C

    1999-01-01

    Scope and Method of Study: The purpose of this study was to examine relationships between both officer rank and officer gender and both club membership and member usage at Air Force officers' clubs in the Continental United States (CONUS...

  13. Soil-air exchange of organochlorine pesticides in the Southern United States

    International Nuclear Information System (INIS)

    Bidleman, Terry F.; Leone, Andi D.

    2004-01-01

    Soil samples were collected from 30 farms in Alabama, Louisiana and Texas during 1999-2000 to determine residues of organochlorine pesticides (OCPs). One or more of the DDT compounds (p,p'-DDT, o,p'-DDT, p,p'-DDD, p,p'-DDE, o,p'-DDE) was above the quantitation limit (0.1 ng g -1 dry weight) in every soil, and toxaphene was above the quantitation limit (3 ng g -1 ) in 26 soils. Chlordanes, dieldrin and hexachlorocyclohexane (HCH) isomers occurred less frequently (quantitation limits 0.1 ng g -1 for dieldrin and 0.05 ng g -1 for chlordanes and HCHs). OCPs were measured in air at 40 cm above the soil at selected farms to investigate soil-air partitioning. Concentrations of OCPs in air were positively and significantly (P s and f a ) for samples with quantifiable residues in both compartments. The fugacity fraction ((f s )/(f s +f a ))=0.5 at equilibrium and is 0.5 for net deposition and net volatilisation, respectively. Fugacity fractions varied greatly for different soil-air pairs, reflecting generally disequilibrium conditions. Mean fugacity fractions indicated near-equilibrium for some OCPs (p,p'-DDE, chlordanes, trans-nonachlor and dieldrin) and net volatilisation for others (p,p'-DDT, o,p'-DDT, toxaphene, γ-HCH). Chiral analysis showed that enantioselective degradation of (+) or (-) o,p'-DDT in soil was accompanied by enrichment or depletion of the corresponding enantiomers in the overlying air, although there appeared to be some dilution by racemic o,p'-DDT from regional air transport. - Old pesticide residues in agricultural soils continue to be emitted into the atmosphere

  14. Development of a method for calculating steady-state equipment sensible heat ratio of direct expansion air conditioning units

    International Nuclear Information System (INIS)

    Xia Liang; Chan, M.Y.; Deng Shiming

    2008-01-01

    A complete set of calculation method for steady-state equipment sensible heat ratio (SHR) for a direct expansion (DX) cooling coil has been developed and reported. The method was based on the fundamentals of energy conservation and heat and mass transfer taking place in the DX cooling coil, and was experimentally validated using an experimental DX A/C rig. With the method developed, the effect of refrigerant evaporating temperature at fixed inlet air conditions on equipment SHR has been theoretically analyzed. The validated method can be useful in further studying the inherent operating characteristics of a DX air conditioning (A/C) unit and in developing suitable control strategies for achieving higher energy efficiency and better indoor thermal environment

  15. Integrated Testing of a 4-Bed Molecular Sieve, Air-Cooled Temperature Swing Adsorption Compressor, and Sabatier Engineering Development Unit

    Science.gov (United States)

    Knox, James C.; Miller, Lee; Campbell, Melissa; Mulloth, Lila; Varghese, Mini

    2006-01-01

    Accumulation and subsequent compression of carbon dioxide that is removed from the space cabin are two important processes involved in a closed-loop air revitalization scheme of the International Space Station (ISS). The 4-Bed Molecular Sieve (4BMS) of ISS currently operates in an open loop mode without a compressor. The Sabatier Engineering Development Unit (EDU) processes waste CO2 to provide water to the crew. This paper reports the integrated 4BMS, air-cooled Temperature Swing Adsorption Compressor (TSAC), and Sabatier EDU testing. The TSAC prototype was developed at NASA Ames Research Center (ARC). The 4BMS was modified to a functionally flight-like condition at NASA Marshall Space Flight Center (MSFC). Testing was conducted at MSFC. The paper provides details of the TSAC operation at various CO2 loadings and corresponding performance of the 4BMS and Sabatier.

  16. Lifetime and current sexual assault and harassment victimization rates of active-duty United States Air Force women.

    Science.gov (United States)

    Bostock, Deborah J; Daley, James G

    2007-09-01

    From a stratified random sample, 2,018 active-duty United States Air Force women completed a telephone survey dealing with sexual assault and harassment. The lifetime prevalence of rape among Air Force women (28%) was more than twice as high as the prevalence in a national sample (13%). Nearly half of the military sample had been the victims of rape, molestation, or attempted sexual assault. The majority of both initial rapes (75%) and most recent rapes (56%) involved assault by civilians when the victims were civilians. Family members perpetrated 29% of initial rapes and 33% of most recent rapes. Regarding military status of the perpetrator, 14% of first-time victims were raped by a military member, 26% of multiple-time victims were raped by a military member, 31.8% of military women were sexually harassed by a military supervisor or boss, and 26.7% of military women were sexually harassed by a military coworker.

  17. Data-handling system for the Fly's Eye experiment

    International Nuclear Information System (INIS)

    Bergeson, H.E.; Cassiday, G.L.; Cooper, D.A.

    1975-01-01

    The Fly's Eye air scintillation experiment presents severe data-handling requirements for two reasons. First, nearly 1,000 photomultipliers each produce outputs at rates from 100 Khz to 20 Mhz. Second, much of the signal arrives before a trigger is formed. A data handling system which will deal with this problem is described. (orig.) [de

  18. Practices of Handling

    DEFF Research Database (Denmark)

    Ræbild, Ulla

    to touch, pick up, carry, or feel with the hands. Figuratively it is to manage, deal with, direct, train, or control. Additionally, as a noun, a handle is something by which we grasp or open up something. Lastly, handle also has a Nordic root, here meaning to trade, bargain or deal. Together all four...... meanings seem to merge in the fashion design process, thus opening up for an embodied engagement with matter that entails direction giving, organizational management and negotiation. By seeing processes of handling as a key fashion methodological practice, it is possible to divert the discourse away from...... introduces four ways whereby fashion designers apply their own bodies as tools for design; a) re-activating past garment-design experiences, b) testing present garment-design experiences c) probing for new garment-design experiences and d) design of future garment experiences by body proxy. The paper...

  19. Remote handling at LAMPF

    International Nuclear Information System (INIS)

    Grisham, D.L.; Lambert, J.E.

    1983-01-01

    Experimental area A at the Clinton P. Anderson Meson Physics Facility (LAMPF) encompasses a large area. Presently there are four experimental target cells along the main proton beam line that have become highly radioactive, thus dictating that all maintenance be performed remotely. The Monitor remote handling system was developed to perform in situ maintenance at any location within area A. Due to the complexity of experimental systems and confined space, conventional remote handling methods based upon hot cell and/or hot bay concepts are not workable. Contrary to conventional remote handling which require special tooling for each specifically planned operation, the Monitor concept is aimed at providing a totally flexible system capable of remotely performing general mechanical and electrical maintenance operations using standard tools. The Monitor system is described

  20. TRANSPORT/HANDLING REQUESTS

    CERN Multimedia

    Groupe ST/HM

    2002-01-01

    A new EDH document entitled 'Transport/Handling Request' will be in operation as of Monday, 11th February 2002, when the corresponding icon will be accessible from the EDH desktop, together with the application instructions. This EDH form will replace the paper-format transport/handling request form for all activities involving the transport of equipment and materials. However, the paper form will still be used for all vehicle-hire requests. The introduction of the EDH transport/handling request form is accompanied by the establishment of the following time limits for the various services concerned: 24 hours for the removal of office items, 48 hours for the transport of heavy items (of up to 6 metric tons and of standard road width), 5 working days for a crane operation, extra-heavy transport operation or complete removal, 5 working days for all transport operations relating to LHC installation. ST/HM Group, Logistics Section Tel: 72672 - 72202

  1. Safe handling of plutonium: a panel report

    Energy Technology Data Exchange (ETDEWEB)

    1974-01-01

    This guide results from a meeting of a Panel of Experts held by the International Atomic Energy Agency on 8 to 12 November 1971. It is directed to workers in research laboratories handling plutonium in gram amounts. Contents: aspects of the physical and chemical properties of plutonium; metabolic features of plutonium; facility design features for safe handling of plutonium (layout of facility, working zones, decontamination room, etc.); glove boxes; health surveillance (surveillance of environment and supervision of workers); emergencies; organization. Annexes: types of glove boxes; tables; mobile ..cap alpha.. air sampler; aerosol monitor; bio-assay limits of detection; examples of contamination control monitors.

  2. The United States Air Force Expeditionary Center: Airpower from the Ground Up

    Science.gov (United States)

    2010-01-01

    On the bookshelf of the Air Force’s advanced training capabilities, the USAF photo Expeditionary Airmen of the 96th Aero Squadron, American...bookends of this bookshelf is the ability to evolve with the speed of change and thus remain relevant to Airmen charged with over-the-horizon global

  3. AIR PERMIT COMPLIANCE FOR WASTE RETRIEVAL OEPRATIONS INVOLVING MULTI-UNIT EMISSIONS

    International Nuclear Information System (INIS)

    SIMMONS FM

    2007-01-01

    Since 1970, approximately 38,000 suspect-transuranic and transuranic waste containers have been placed in retrievable storage on the Hanford Site in the 200 Areas burial grounds. Hanford's Waste Retrieval Project is retrieving these buried containers and processing them for safe storage and disposition. Container retrieval activities require an air emissions permit to account for potential emissions of radionuclides. The air permit covers the excavation activities as well as activities associated with assaying containers and installing filters in the retrieved transuranic containers lacking proper venting devices. Fluor Hanford, Inc. is required to track radioactive emissions resulting from the retrieval activities. Air, soil, and debris media contribute to the emissions and enabling assumptions allow for calculation of emissions. Each of these activities is limited to an allowed annual emission (per calendar year) and .contributes to the overall total emissions allowed for waste retrieval operations. Tracking these emissions is required to ensure a permit exceedance does not occur. A tracking tool was developed to calculate potential emissions in real time sense. Logic evaluations are established within the tracking system to compare real time data against license limits to ensure values are not exceeded for either an individual activity or the total limit. Data input are based on field survey and workplace air monitoring activities. This tracking tool is used monthly and quarterly to verify compliance to the license limits. Use of this tool has allowed Fluor Hanford, Inc. to successfully retrieve a significant number of containers in a safe manner without any exceedance of emission limits

  4. United States Air Force Statistical Digest, Fiscal Year 1979, Thirty-Fourth Edition

    Science.gov (United States)

    1980-06-30

    Greenland Guam. Guatemala Haiti Honduras. 1I0ng Kong Hungary Iceland India Indonesia Iran. Ireland Israel. Italy Japan Johnston Island Jordan. 1 1 6...Senaration, or an Entry in the Air Force Strength as a Pesult of Data or Strength Pecan Not Invo]ving Reenlistment .nctions. Deletion of Previously Peported

  5. The climate and air-quality benefits of wind and solar power in the United States

    Science.gov (United States)

    Millstein, Dev; Wiser, Ryan; Bolinger, Mark; Barbose, Galen

    2017-09-01

    Wind and solar energy reduce combustion-based electricity generation and provide air-quality and greenhouse gas emission benefits. These benefits vary dramatically by region and over time. From 2007 to 2015, solar and wind power deployment increased rapidly while regulatory changes and fossil fuel price changes led to steep cuts in overall power-sector emissions. Here we evaluate how wind and solar climate and air-quality benefits evolved during this time period. We find cumulative wind and solar air-quality benefits of 2015 US$29.7-112.8 billion mostly from 3,000 to 12,700 avoided premature mortalities, and cumulative climate benefits of 2015 US$5.3-106.8 billion. The ranges span results across a suite of air-quality and health impact models and social cost of carbon estimates. We find that binding cap-and-trade pollutant markets may reduce these cumulative benefits by up to 16%. In 2015, based on central estimates, combined marginal benefits equal 7.3 ¢ kWh-1 (wind) and 4.0 ¢ kWh-1 (solar).

  6. Ideas, Concepts, Doctrine: Basic Thinking in the United States Air Force, 1961-1984. Volume 2

    Science.gov (United States)

    1989-12-01

    air power was concerned was a little bit of what I used to refer to as operational masturbation . I have always felt the B-52s were to a large extent...Procurement (a modification of the present Installations and Logistics) ; (e) Manpower and Reserve Affairs ; (f) Health and Environmental Affairs ; (g

  7. POLLUTION PREVENTION OPPORTUNITY ASSESSMENT - UNITED STATES NAVAL BASE NORFOLK NAVAL AIR STATION

    Science.gov (United States)

    This report summarizes work conducted at the U.S. Navy's Naval Base Norfolk, Naval Air Station (NAS) located at Sewells Point in Norfolk, Virginia, under the U.S. Environmental Protection Agency's (EPA) Waste Reduction Evaluations at Federal Sites (WREAFS) Program. This project w...

  8. United States Air Force F-35A Operational Basing Environmental Impact Statement. Appendix E: Comments

    Science.gov (United States)

    2013-09-01

    forbid, tobacco smoking in or around your home. • Switch to non-toXic cleaning products (such as baking soda, hydrogen peroxide and vinegar) and safer...checked false assertion that the Air Force impact study was "a boiler plate document that was not specific to our area." Several reports attributed

  9. 77 FR 35836 - Amendment of Air Traffic Service Routes; Southwestern United States

    Science.gov (United States)

    2012-06-15

    ...This action modifies Jet Route J-2, and VOR Federal airways V- 16, V-66 and V-202 in southern Arizona and New Mexico due to the scheduled decommissioning of the Cochise, AZ, VHF Omnidirectional Range Tactical Air Navigation (VORTAC) which currently is used to define segments of the routes.

  10. Impact of Transpacific Aerosol on Air Quality over the United States: A Perspective from Aerosol-Cloud-Radiation Interactions

    Science.gov (United States)

    Tao, Zhining; Yu, Hongbin; Chin, Mian

    2015-01-01

    Observations have well established that aerosols from various sources in Asia, Europe, and Africa can travel across the Pacific and reach the contiguous United States (U.S.) at least on episodic bases throughout a year, with a maximum import in spring. The imported aerosol not only can serve as an additional source to regional air pollution (e.g., direct input), but also can influence regional air quality through the aerosol-cloud-radiation (ACR) interactions that change local and regional meteorology. This study assessed impacts of the transpacific aerosol on air quality, focusing on surface ozone and PM2.5, over the U.S. using the NASA Unified Weather Research Forecast model. Based on the results of 3- month (April to June of 2010) simulations, the impact of direct input (as an additional source) of transpacific aerosol caused an increase of surface PM2.5 concentration by approximately 1.5 micro-g/cu m over the west coast and about 0.5 micro-g/cu m over the east coast of the U.S. By influencing key meteorological processes through the ACR interactions, the transpacific aerosol exerted a significant effect on both surface PM2.5 (+/-6 micro-g/cu m3) and ozone (+/-12 ppbv) over the central and eastern U.S. This suggests that the transpacific transport of aerosol could either improve or deteriorate local air quality and complicate local effort toward the compliance with the U.S. National Ambient Air Quality Standards.

  11. 77 FR 64414 - Approval and Promulgation of Air Quality Implementation Plans; United States Virgin Islands...

    Science.gov (United States)

    2012-10-22

    ... deciviews (the Reasonable Progress Goal). Comment: HOVENSA commented that EPA has no rational basis for..., petitions for judicial review of this action must be filed in the United States Court of Appeals for the...

  12. 76 FR 57902 - Amendment and Establishment of Air Traffic Service Routes; Northeast United States

    Science.gov (United States)

    2011-09-19

    ... Routes; Northeast United States AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule.../DME 040[deg] radial northeast of Kennedy VOR/DME. V-16 then turns east bound, bypassing the Deer Park...

  13. United States Air Force Summer Faculty Research Program 1989. Program Technical Report. Volume 1

    Science.gov (United States)

    1989-12-01

    Nebel Limb Radiances Under Sunlit Conditions in the 50-120 KM Altitude Range 61 Estimating Solar Flare Proton Fluences Dr. Hugh Nutley From 1850 with...MCD spectrum. The y axis units are, therefore, absorbance/ Tesla . The sensitivity of the apparatus was estimated to be 0.01 absorbance unit with 1000...the roof and walls, is placed. As a final step the excavated soil is used to cover the structure leaving the entrance and exit ramps open. The

  14. Penggunaan Unit Slow Sand Filter, Ozon Generator dan Rapid Sand Filter Skala Rumah Tangga Untuk Meningkatkan Kualitas Air Sumur Dangkal Menjadi Air Layak Minum (Parameter Zat Organik dan Deterjen

    Directory of Open Access Journals (Sweden)

    Anindya Prawita Sari

    2014-09-01

    Full Text Available Air sumur merupakan air tanah yang sering kali digunakan masyarakat untuk aktivitas sehari-hari. Air sumur dengan kadar organik dan deterjen tinggi tidak layak dikonsumsi masyarakat karena dapat menyebabkan berbagai macam penyakit. Selain itu, adanya zat organik dan deterjen mempengaruhi warna dan bau air sumur sehingga tidak layak konsumsi. Slow sand filter merupakan unit pengolahan yang mampu meremoval zat organik pada air. Slow sand filter dan rapid sand filter tidak menggunakan bahan kimia dalam proses pengolahan sehingga lebih ekonomis dan efektif. Sedangkan ozon, efektif digunakan untuk meremoval zat organik yang ada dalam air dengan mengubah rantai zat organik menjadi lebih sederhana. Tujuan penelitian ini adalah untuk mengetahui keefektifan penggunaan slow sand filter, ozon generator dan rapid sand filter dalam menyisihkan beban deterjen dan zat organik pada air sumur. Hasil penelitian menunjukkan bahwa efisiensi removal pada unit slow sand filter untuk beban organik dan deterjen sebesar 57,6% dan 60,5 %, pada unit ozonasi sebesar 47,4% dan 17,5%, dan pada unit rapid sand filter sebesar 50,0% dan 50,9 %.

  15. The issue of radon and daughters in water and in air detection using the detection unit 'YAPMARE'

    International Nuclear Information System (INIS)

    Thinova, L.; Trojek, T.; Kunka, A.; Maly, P.; Blazek, K.; Notaristefani, F. de; Moucka, L.

    2004-01-01

    The specialized detection unit YAPMARE was developed by company CRYTUR Ltd. The main part of the detection unit is a detection probe based on a 100 mm x 25 mm diam. YAP:Ce detector, made of monocrystalline YAP:Ce (chemical formula is YAlO 3 doped Ce) grown by Crytur Ltd. YAP:Ce crystal advantages are in chemical resistance, good mechanical properties, nonhygroscopicity and ease of polishing; remainder of radionuclides deposited on the Teflon surface can be easily deactivated using HCl acid. The detection unit was developed for 222 Rn and its daughter's measurement in water under extreme conditions (pressure, temperature and acidity) to obtain additional information about flow dynamics in Earth crust. The detection volume for water (or air) is 12 ml and in this case the measured medium covers approximately 95% of the crystal surface, while the remaining 5% is a spiral groove machined into the Teflon enclosure (used as a reflector). Spectrometry results of the measurement are an advantage for data processing. The main points of 'YAPMARE' unit testing are as follows: Methodology of water sample collection, defining the optimum measurement time interval; Energetic stability monitoring; Gamma ray energetic calibration using etalons and natural radioactive rock; Alpha ray energetic calibration using dry (air) standards of 222 Rn and 220 Rn, with peaks in alpha spectrum identification; The gamma background elimination during measurement and in data processing; Measuring the high 222 Rn water activity (Svornost mine in Jachymov - radon activity 17 kBq/l); Probe calibration for radon-in-water determination (using fresh water from a drilled well in Lounovice near Prague and using a 222 Rn water standard). Due to the large crystal volume all measurements were conducted inside a Pb shield 25 mm thick. The water alpha activity was also monitored using radon monitor RADIM 4. All results of testing will be presented. (author)

  16. Safe handling of tritium

    International Nuclear Information System (INIS)

    1991-01-01

    The main objective of this publication is to provide practical guidance and recommendations on operational radiation protection aspects related to the safe handling of tritium in laboratories, industrial-scale nuclear facilities such as heavy-water reactors, tritium removal plants and fission fuel reprocessing plants, and facilities for manufacturing commercial tritium-containing devices and radiochemicals. The requirements of nuclear fusion reactors are not addressed specifically, since there is as yet no tritium handling experience with them. However, much of the material covered is expected to be relevant to them as well. Annex III briefly addresses problems in the comparatively small-scale use of tritium at universities, medical research centres and similar establishments. However, the main subject of this publication is the handling of larger quantities of tritium. Operational aspects include designing for tritium safety, safe handling practice, the selection of tritium-compatible materials and equipment, exposure assessment, monitoring, contamination control and the design and use of personal protective equipment. This publication does not address the technologies involved in tritium control and cleanup of effluents, tritium removal, or immobilization and disposal of tritium wastes, nor does it address the environmental behaviour of tritium. Refs, figs and tabs

  17. Grain Grading and Handling.

    Science.gov (United States)

    Rendleman, Matt; Legacy, James

    This publication provides an introduction to grain grading and handling for adult students in vocational and technical education programs. Organized in five chapters, the booklet provides a brief overview of the jobs performed at a grain elevator and of the techniques used to grade grain. The first chapter introduces the grain industry and…

  18. Mars Sample Handling Functionality

    Science.gov (United States)

    Meyer, M. A.; Mattingly, R. L.

    2018-04-01

    The final leg of a Mars Sample Return campaign would be an entity that we have referred to as Mars Returned Sample Handling (MRSH.) This talk will address our current view of the functional requirements on MRSH, focused on the Sample Receiving Facility (SRF).

  19. Handling wood shavings

    Energy Technology Data Exchange (ETDEWEB)

    1974-09-18

    Details of bulk handling equipment suitable for collection and compressing wood waste from commercial joinery works are discussed. The Redler Bin Discharger ensures free flow of chips from storage silo discharge prior to compression into briquettes for use as fuel or processing into chipboard.

  20. International system of units traceable results of Hg mass concentration at saturation in air from a newly developed measurement procedure.

    Science.gov (United States)

    Quétel, Christophe R; Zampella, Mariavittoria; Brown, Richard J C; Ent, Hugo; Horvat, Milena; Paredes, Eduardo; Tunc, Murat

    2014-08-05

    Data most commonly used at present to calibrate measurements of mercury vapor concentrations in air come from a relationship known as the "Dumarey equation". It uses a fitting relationship to experimental results obtained nearly 30 years ago. The way these results relate to the international system of units (SI) is not known. This has caused difficulties for the specification and enforcement of limit values for mercury concentrations in air and in emissions to air as part of national or international legislation. Furthermore, there is a significant discrepancy (around 7% at room temperature) between the Dumarey data and data calculated from results of mercury vapor pressure measurements in the presence of only liquid mercury. As an attempt to solve some of these problems, a new measurement procedure is described for SI traceable results of gaseous Hg concentrations at saturation in milliliter samples of air. The aim was to propose a scheme as immune as possible to analytical biases. It was based on isotope dilution (ID) in the liquid phase with the (202)Hg enriched certified reference material ERM-AE640 and measurements of the mercury isotope ratios in ID blends, subsequent to a cold vapor generation step, by inductively coupled plasma mass spectrometry. The process developed involved a combination of interconnected valves and syringes operated by computer controlled pumps and ensured continuity under closed circuit conditions from the air sampling stage onward. Quantitative trapping of the gaseous mercury in the liquid phase was achieved with 11.5 μM KMnO4 in 2% HNO3. Mass concentrations at saturation found from five measurements under room temperature conditions were significantly higher (5.8% on average) than data calculated from the Dumarey equation, but in agreement (-1.2% lower on average) with data based on mercury vapor pressure measurement results. Relative expanded combined uncertainties were estimated following a model based approach. They ranged from 2

  1. Transient modeling of an air conditioner with a rapid cycling compressor and multi-indoor units

    International Nuclear Information System (INIS)

    Zhang Weijiang; Zhang Chunlu

    2011-01-01

    Rapid cycling the compressor is an alternative of the variable speed compressor to modulate the capacity of refrigeration systems for the purpose of energy saving at part-load conditions. The multi-evaporator air conditioner combined with the rapid cycling compressor brings difficulties in control design because of the sophisticated system physics and dynamics. In this paper the transient model of a multi-split air conditioner with a digital scroll compressor is developed for predicting the system transients under performance modulations. The predicted cycling dynamics are in good agreement with the experimental data. Based on the validated model, the impact of compressor idle power and cycle period to the part load performance is discussed.

  2. Transient modeling of an air conditioner with a rapid cycling compressor and multi-indoor units

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Wei-Jiang [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240 (China); Zhang, Chun-Lu [College of Mechanical Engineering, Tongji University, 4800 Cao An Highway, Shanghai 201804 (China)

    2011-01-15

    Rapid cycling the compressor is an alternative of the variable speed compressor to modulate the capacity of refrigeration systems for the purpose of energy saving at part-load conditions. The multi-evaporator air conditioner combined with the rapid cycling compressor brings difficulties in control design because of the sophisticated system physics and dynamics. In this paper the transient model of a multi-split air conditioner with a digital scroll compressor is developed for predicting the system transients under performance modulations. The predicted cycling dynamics are in good agreement with the experimental data. Based on the validated model, the impact of compressor idle power and cycle period to the part load performance is discussed. (author)

  3. Transient modeling of an air conditioner with a rapid cycling compressor and multi-indoor units

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Weijiang [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240 (China); Zhang Chunlu, E-mail: chunlu.zhang@carrier.utc.co [College of Mechanical Engineering, Tongji University, 4800 Cao An Highway, Shanghai 201804 (China)

    2011-01-15

    Rapid cycling the compressor is an alternative of the variable speed compressor to modulate the capacity of refrigeration systems for the purpose of energy saving at part-load conditions. The multi-evaporator air conditioner combined with the rapid cycling compressor brings difficulties in control design because of the sophisticated system physics and dynamics. In this paper the transient model of a multi-split air conditioner with a digital scroll compressor is developed for predicting the system transients under performance modulations. The predicted cycling dynamics are in good agreement with the experimental data. Based on the validated model, the impact of compressor idle power and cycle period to the part load performance is discussed.

  4. Installation Restoration Program. Phase 1. Records Search, United States Air Force Academy, Colorado Springs, Colorado

    Science.gov (United States)

    1984-12-01

    SOURCE: U.S. Air Force Academy, Tab A-i, Environmental Narrative Woodland Biome Zone (6000-7000 feet) SPECIES U Trees 3 . ’Ponderosa pine Pinus ...Highest Frequency of Occurrence U SPECIES 3 Trees 1. Ponderosa pine Pinus ponderosa var scopulorum 3 2. Douglas fir Pseudotsuga menzlesii 3. White...LYSIMETER A vacuum operated sampling device used for extracting pore waters at various I depths within the unsaturated zone. I G-6 I I * i MEK Methyl Ethyl

  5. United States Air Force Unmanned Aircraft Systems Flight Plan 2009-2047

    Science.gov (United States)

    2009-05-18

    future challenges facing the USAF and the Joint Force through 2047. Michael B. Donley Secretary of the Air Force - 3 - AJI ¥-Jcf2c .~~~ Norton A...is depicted along a DOTMLPF-P stratified timeline as a colored triangle. Red triangles represent actions that require senior leader involvement to...Flag, and Red Flag. Joint UAS training may lead to greater training efficiencies and standardization. Training standards may be applied based on the

  6. Innovation in the United States Air Force: Evidence from Six Cases

    Science.gov (United States)

    2016-01-01

    PAVN People’s Army of Vietnam PGM precision guided munitions RPA remotely piloted aircraft RWR radar warning receivers SAAS School of Advanced...related subjects to the establishment in 1990 of the School of Advanced Airpower Studies ( SAAS ), which provides graduate-level education to officers likely...Storm have been SAAS alumni.268 Emergence of the Innovation A host of factors set the stage for the emergence of the precision-attack air campaign

  7. United States Air Force High School Apprenticeship Program. 1990 Program Management Report. Volume 1

    Science.gov (United States)

    1991-04-18

    Chuang 86 Mesoscale Modeling Christopher Guild 87 No Report Submitted Jason Klingensmith 88 Solar Terrestrial Interactions Galen McKinley 89 Ionospheric...approximately 7.4 Tesla between its poles. The sample is spun about its main field (Z) axis by a stream of air to average out any existing homogeneities in the...move to a specific azimuth and elevation to track individual targets. Both antennas are located on the roof of the building 13 annex, directly above

  8. Urban air pollution and respiratory emergency visits at pediatric unit, Reggio Emilia, Italy.

    Science.gov (United States)

    Bedeschi, Emanuela; Campari, Cinzia; Candela, Silvia; Collini, Giorgia; Caranci, Nicola; Frasca, Gabriella; Galassi, Claudia; Francesca, Gabriella; Vigotti, Maria Angela

    2007-02-01

    Short-term effects of air pollution on daily mortality and hospital admissions for respiratory causes are well documented. Few studies, however, explore the association between exposure to air pollution and daily emergency room visits for respiratory disorders, particularly in Italy and particularly among children as a susceptible population. A time-series analysis was conducted to explore the short-term association between air pollutants (PM10, total suspended particulates [TSP], NO2, SO2, CO, O3) and pediatric emergency room (ER) visits in a small city of northern Italy, Reggio Emilia, during the period 03/01/2001-03/31/2002. There were 1051 ER visits included in the study. Data were analyzed using generalized additive models (GAM), adjusting for various confounding variables, including temperature, humidity, and pollens (Graminaceae). The analyses were also stratified according to the nationality of children (Italians and foreigners). In single-pollutant models, the strongest associations were observed at lag 3 for a 10-microg/m3 increase of TSP (2.7% increase in ER, 95% CI 0.7-4.6) and PM10 (3.0% increase, 95% CI 0.4-5.7), and at lag 4 for a 10-microg/m3 increase of NO2 (11.0% increase in ER, 95% CI 3.6-18.8). At lag 3, the percentage increase in ER visits is similar for the 2 groups of children (Italians and foreigners) for TSP and PM10. The results of the study support the findings that air pollution is a relevant determinant of deterioration of respiratory health among children.

  9. 77 FR 71129 - Revisions to the California State Implementation Plan, San Joaquin Valley United Air Pollution...

    Science.gov (United States)

    2012-11-29

    ...EPA is finalizing approval of revisions to the SJVUAPCD and SCAQMD portion of the California State Implementation Plan (SIP). This action was proposed in the Federal Register on June 21, 2012 and concerns volatile organic compound (VOC) emissions from chipping and grinding activities, and composting operations. We are approving local rules that regulate these emission sources under the Clean Air Act (CAA or the Act).

  10. Challenges to United States Tactical Air Force Aircraft Maintenance Personnel: Past, Present and Future

    Science.gov (United States)

    1991-09-01

    study f-ocuses on the most 3 recent changes faced by the TAF rraintenance organization. The last chapter comprares and contrasts the development of... forma - tions. But during the interwar years, both of these missions went into eclipse as doctrinal thinkers established the primacy of bombardment as...i.sninent" (15:4). In response to tho! USAF taskin:g, TAC activated Headquarters Nine- teenth Air force and mr- de it solely reaponsible for planning "for

  11. United States Air Force Statistical Digest, Fiscal Year 1978. Thirty-Third Edition

    Science.gov (United States)

    1979-05-31

    8217!i c:J 0 MC-13LM 1 61" 112.. 1&~.1 ~~ 2 517 12li8 205.1c: 3 ,,& lOU Ul ...en .. Ufo 1111& 192.’ c: "’! en "’tOTAL .2lt7S ..581 115.1 ! ! IIC-13~" 1...investigations conducted for other federal agencies; premarital investigations of intended alien spouses of Air Force military personnel. UNCLASSIFIED

  12. The United States Air Force and Humanitarian Airlift Operations 1947-1994

    Science.gov (United States)

    1998-01-01

    Ecuador . Aftershocks in southern Ecuador on December 10 compounded the destruction in cities and villages such as Loja , Cariamango, Celica, and Alamor... Ecuador . Date(s): August 10–19, 1949. Emergency: An earthquake measuring 7.5 on the Richter scale struck central Ecuador . Air Force Organization(s...Operations: A severe earthquake registering 7.5 on the Richter scale struck the high valleys of central Ecuador in the Andes on Thursday, August 4

  13. The United States Air Force in Southeast Asia. The Advisory Years to 1965

    Science.gov (United States)

    1981-01-01

    Improved govcinmiental financial procedui s: border and coastal patrols to stop infiltra- tion and outside support of thle antr-government guerrillas...if the South Vietnamese economy could sustain enlaiged military forces. Kennedy sent a financial survey group headed by Dr. Eugene Staley to Saigon...ell Air IorcelBase. Ala Aerospace Studies Instituite . 1964 P’artner. J.. and Strirms’er. NI J The Evoluition of i/u’ Airborne torn tard ’hr Controller

  14. 77 FR 24156 - Proposed Amendment of Air Traffic Service Routes; Southwestern United States

    Science.gov (United States)

    2012-04-23

    ...This action proposes to modify Jet Route J-2, and VOR Federal airways V-16, V-66, and V-202 in southern Arizona and New Mexico. The FAA is proposing this action due to the scheduled decommissioning of the Cochise, AZ, VHF omnirange tactical air navigation aid (VORTAC) which currently forms segments of the routes. This would enhance enroute navigation within the National Airspace System.

  15. United States Air Force F-35A Operational Basing Environmental Impact Statement. Appendix E: Comments

    Science.gov (United States)

    2013-09-01

    famous for progressive legislation that encourages inclusivenessJ peace and equality. We are famous for our green pastures and our Vermont village...patterns that all preserve special senses of place. We are not known for jobs at all cost, we do not allow heavy industry to pollute our air or...Winooski Vermont, we are deeply committed to t he preservation of th is unique historic treasure. Unfortunately, we find that your identification and

  16. Incidence of Boxing Injuries in the Royal Air Force in the United Kingdom 1953—66

    Science.gov (United States)

    Brennan, T. N. N.; O'Connor, P. J.

    1968-01-01

    Statistics of injuries arising in amateur boxing in the Royal Air Force in the 14 years 1953-66 are given. There were 240 injuries including two deaths in the 14 years. During the seven years 1960-66, four men out of every thousand entering the ring received injuries to the head or neck which kept them off work for 48 hours or more. No case of the punch-drunk syndrome was seen. PMID:5723355

  17. Impacts of potential CO2-reduction policies on air quality in the United States.

    Science.gov (United States)

    Trail, Marcus A; Tsimpidi, Alexandra P; Liu, Peng; Tsigaridis, Kostas; Hu, Yongtao; Rudokas, Jason R; Miller, Paul J; Nenes, Athanasios; Russell, Armistead G

    2015-04-21

    Impacts of emissions changes from four potential U.S. CO2 emission reduction policies on 2050 air quality are analyzed using the community multiscale air quality model (CMAQ). Future meteorology was downscaled from the Goddard Institute for Space Studies (GISS) ModelE General Circulation Model (GCM) to the regional scale using the Weather Research Forecasting (WRF) model. We use emissions growth factors from the EPAUS9r MARKAL model to project emissions inventories for two climate tax scenarios, a combined transportation and energy scenario, a biomass energy scenario and a reference case. Implementation of a relatively aggressive carbon tax leads to improved PM2.5 air quality compared to the reference case as incentives increase for facilities to install flue-gas desulfurization (FGD) and carbon capture and sequestration (CCS) technologies. However, less capital is available to install NOX reduction technologies, resulting in an O3 increase. A policy aimed at reducing CO2 from the transportation sector and electricity production sectors leads to reduced emissions of mobile source NOX, thus reducing O3. Over most of the U.S., this scenario leads to reduced PM2.5 concentrations. However, increased primary PM2.5 emissions associated with fuel switching in the residential and industrial sectors leads to increased organic matter (OM) and PM2.5 in some cities.

  18. Ergonomics intervention in manual handling of oxygen

    Directory of Open Access Journals (Sweden)

    M Motamedzadeh

    2013-05-01

    Conclusion: With the implementation of ergonomic intervention is casting unit, the risk of exposure to musculoskeletal disorders caused by manual handling of oxygen cylinders was eliminated and safety of employees against the risk of explosion of the cylinders in comparison with before the intervention was improved.

  19. Ventilation and air conditioning systems in maritime productions units; Panorama dos sistemas de VAC em unidades maritimas de producao

    Energy Technology Data Exchange (ETDEWEB)

    Guedes, Fernando Pedrosa; Sztajnbok, Ernani Luis [PETROBRAS, Rio de Janeiro, RJ (Brazil); Padua, Carlos Eduardo Dantas de; Passos, Alfredo Silveira [DUOVAC Engenharia Ltda. (Brazil)

    2004-07-01

    In an Offshore Stationary Production Unit (SPU), the adequate project of the Ventilation and Air Conditioning (VAC) System is not only a thermal comfort requirement but part of the essential safety services of the installation and complement for area classification requirements associated with electrical equipment. The VAC installations are sometimes the object of complaints by onboard team. Problems such as unsatisfactory system performance, high noise levels in the accommodation quarters, offices and other areas and the discomfort caused by unbalanced ventilation and air conditioning systems, are some of the most frequent complaints. Air Conditioning systems are classified as Direct and Indirect Expansion. Decentralized systems with Indirect Expansion has been adopted in PETROBRAS projects. This conception is not used in VAC Systems for platforms installed in North Sea, where the use of Centralized Systems with Direct Expansion are more common. The objective of this work is to compare the VAC conception projects, analyzing their advantages and disadvantages . The evaluation of VAC System in PETROBRAS project, and their steps in SPU development, is also scope of this paper. (author)

  20. TiO2-Impregnated Porous Silica Tube and Its Application for Compact Air- and Water-Purification Units

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Ochiai

    2015-09-01

    Full Text Available A simple, convenient, reusable, and inexpensive air- and water-purification unit including a one-end sealed porous amorphous-silica (a-silica tube coated with TiO2 photocatalyst layers has been developed. The porous a-silica layers were formed through outside vapor deposition (OVD. TiO2 photocatalyst layers were formed through impregnation and calcination onto a-silica layers. The resulting porous TiO2-impregnated a-silica tubes were evaluated for air-purification capacity using an acetaldehyde gas decomposition test. The tube (8.5 mm e.d. × 150 mm demonstrated a 93% removal rate for high concentrations (ca. 300 ppm of acetaldehyde gas at a single-pass condition with a 250 mL/min flow rate under UV irradiation. The tube also demonstrated a water purification capacity at a rate 2.0 times higher than a-silica tube without TiO2 impregnation. Therefore, the tubes have a great potential for developing compact and in-line VOC removal and water-purification units.

  1. The Air Quality and Economic Impact of Atmospheric Lead from General Aviation Aircraft in the United States

    Science.gov (United States)

    Wolfe, P. J.; Selin, N. E.; Barrett, S. R. H.

    2015-12-01

    While leaded fuels for automobiles were phased-out of use in the United States by 1996, lead (Pb) continues to be used as an anti-knock additive for piston-driven aircraft. We model the annual concentration of atmospheric lead attributable to piston driven aircraft emissions in the continental United States using the Community Multi-scale Air Quality (CMAQ) model. Using aircraft emissions inventories for 2008, we then calculate annual economic damages from lead as lifetime employment losses for a one-year cohort exposed to elevated atmospheric lead concentrations using a range of concentration response functions from literature. Mean and median estimates of annual damages attributable to lifetime lost earnings are 1.06 and 0.60 billion respectively. Economy-wide impacts of IQ-deficits on productivity and labor increase expected damages by 54%. Damages are sensitive to background lead concentrations; as emissions decrease from other sources, the damages attributable to aviation are expected to increase holding aviation emissions constant. The monetary impact of General Aviation lead emissions on the environment is the same order of magnitude as noise, climate change, and air quality degradation from all commercial operations.

  2. Analysis and Choice of Optimal Heating Ventilation Air Conditioning System for a Teaching Unit

    Directory of Open Access Journals (Sweden)

    Marina Verdeş

    2007-01-01

    Full Text Available Under the conditions of present society in which providing an optimum interior comfort is confronted with the necessity of the energy consumption reduction, solving this problem depends on the factors which contribute to the achievements of this comfort. Modern buildings -- implicitly teaching unit -- may be equipped with installations which have low energy consumption, respective a heating, cooling and ventilating integrated system with heat pumps system which can assure all the required comfort conditions. This paper underlines the necessity to use the heat pump in heating system for a teaching unit, energetic and economic guides and the possibility to increase them when using cooling and heating mixed. The solution of heat pumps for heating of the teaching unit and the energetic and economic advantages of the system is made in study.

  3. An Alternative Method for Computing Unit Costs and Productivity Ratios. AIR 1984 Annual Forum Paper.

    Science.gov (United States)

    Winstead, Wayland H.; And Others

    An alternative measure for evaluating the performance of academic departments was studied. A comparison was made with the traditional manner for computing unit costs and productivity ratios: prorating the salary and effort of each faculty member to each course level based on the personal mix of course taught. The alternative method used averaging…

  4. Application of inertial measuring unit in air navigation for ALS and DAP

    African Journals Online (AJOL)

    This article describes the inertial measuring device IMU, as well as its use in airborne laser scanning and digital aerial photography. This device is used during the operation of a scanning unit and an aerial photo camera. The structure of an additional connection for a digital video camera is proposed, which will record video ...

  5. Microbial communities related to volatile organic compound emission in automobile air conditioning units.

    Science.gov (United States)

    Diekmann, Nina; Burghartz, Melanie; Remus, Lars; Kaufholz, Anna-Lena; Nawrath, Thorben; Rohde, Manfred; Schulz, Stefan; Roselius, Louisa; Schaper, Jörg; Mamber, Oliver; Jahn, Dieter; Jahn, Martina

    2013-10-01

    During operation of mobile air conditioning (MAC) systems in automobiles, malodours can occur. We studied the microbial communities found on contaminated heat exchanger fins of 45 evaporators from car MAC systems which were operated in seven different regions of the world and identified corresponding volatile organic compounds. Collected biofilms were examined by scanning electron microscopy and fluorescent in situ hybridization. The detected bacteria were loosely attached to the metal surface. Further analyses of the bacteria using PCR-based single-strand conformation polymorphism and sequencing of isolated 16S rRNA gene fragments identified highly divergent microbial communities with multiple members of the Alphaproteobacteriales, Methylobacteria were the prevalent bacteria. In addition, Sphingomonadales, Burkholderiales, Bacillales, Alcanivorax spp. and Stenotrophomonas spp. were found among many others depending on the location the evaporators were operated. Interestingly, typical pathogenic bacteria related to air conditioning systems including Legionella spp. were not found. In order to determine the nature of the chemical compounds produced by the bacteria, the volatile organic compounds were examined by closed loop stripping analysis and identified by combined gas chromatography/mass spectrometry. Sulphur compounds, i.e. di-, tri- and multiple sulphides, acetylthiazole, aromatic compounds and diverse substituted pyrazines were detected. Mathematical clustering of the determined microbial community structures against their origin identified a European/American/Arabic cluster versus two mainly tropical Asian clusters. Interestingly, clustering of the determined volatiles against the origin of the corresponding MAC revealed a highly similar pattern. A close relationship of microbial community structure and resulting malodours to the climate and air quality at the location of MAC operation was concluded.

  6. United States Air Force Statistical Digest, Fiscal Year 1961. Sixteenth Edition

    Science.gov (United States)

    1961-09-30

    active Air Force inventories in a timely and efficient manner. This Is accomplished through redistribution and/or marketing proced~es as set forth in...other than waste, which has no reasonable prospect of sale, or which appears to have no market value other than its basic material content. SURPLUS...Transportation of Persons and Things (28) (1) - (1) (26) 994 Progress Payments • 23,152 3,609 4,663 9,287 5,593 RESEARC ~ DEVELOPMENT, TEST AND EVAL - TOTAL

  7. Test sample handling apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    A test sample handling apparatus using automatic scintillation counting for gamma detection, for use in such fields as radioimmunoassay, is described. The apparatus automatically and continuously counts large numbers of samples rapidly and efficiently by the simultaneous counting of two samples. By means of sequential ordering of non-sequential counting data, it is possible to obtain precisely ordered data while utilizing sample carrier holders having a minimum length. (U.K.)

  8. Handling and Transport Problems

    Energy Technology Data Exchange (ETDEWEB)

    Pomarola, J. [Head of Technical Section, Atomic Energy Commission, Saclay (France); Savouyaud, J. [Head of Electro-Mechanical Sub-Division, Atomic Energy Commission, Saclay (France)

    1960-07-01

    Arrangements for special or dangerous transport operations by road arising out of the activities of the Atomic Energy Commission are made by the Works and Installations Division which acts in concert with the Monitoring and Protection Division (MPD) whenever radioactive substances or appliances are involved. In view of the risk of irradiation and contamination entailed in handling and transporting radioactive substances, including waste, a specialized transport and storage team has been formed as a complement to the emergency and decontamination teams.

  9. Solid waste handling

    International Nuclear Information System (INIS)

    Parazin, R.J.

    1995-01-01

    This study presents estimates of the solid radioactive waste quantities that will be generated in the Separations, Low-Level Waste Vitrification and High-Level Waste Vitrification facilities, collectively called the Tank Waste Remediation System Treatment Complex, over the life of these facilities. This study then considers previous estimates from other 200 Area generators and compares alternative methods of handling (segregation, packaging, assaying, shipping, etc.)

  10. Handling of radioactive waste

    International Nuclear Information System (INIS)

    Sanhueza Mir, Azucena

    1998-01-01

    Based on characteristics and quantities of different types of radioactive waste produced in the country, achievements in infrastructure and the way to solve problems related with radioactive waste handling and management, are presented in this paper. Objectives of maintaining facilities and capacities for controlling, processing and storing radioactive waste in a conditioned form, are attained, within a great range of legal framework, so defined to contribute with safety to people and environment (au)

  11. Renal phosphate handling: Physiology

    Directory of Open Access Journals (Sweden)

    Narayan Prasad

    2013-01-01

    Full Text Available Phosphorus is a common anion. It plays an important role in energy generation. Renal phosphate handling is regulated by three organs parathyroid, kidney and bone through feedback loops. These counter regulatory loops also regulate intestinal absorption and thus maintain serum phosphorus concentration in physiologic range. The parathyroid hormone, vitamin D, Fibrogenic growth factor 23 (FGF23 and klotho coreceptor are the key regulators of phosphorus balance in body.

  12. Long-Term Trend Analysis of Precipitation and Air Temperature for Kentucky, United States

    Directory of Open Access Journals (Sweden)

    Somsubhra Chattopadhyay

    2016-02-01

    Full Text Available Variation in quantities such as precipitation and temperature is often assessed by detecting and characterizing trends in available meteorological data. The objective of this study was to determine the long-term trends in annual precipitation and mean annual air temperature for the state of Kentucky. Non-parametric statistical tests were applied to homogenized and (as needed pre-whitened annual series of precipitation and mean air temperature during 1950–2010. Significant trends in annual precipitation were detected (both positive, averaging 4.1 mm/year for only two of the 60 precipitation-homogenous weather stations (Calloway and Carlisle counties in rural western Kentucky. Only three of the 42 temperature-homogenous stations demonstrated trends (all positive, averaging 0.01 °C/year in mean annual temperature: Calloway County, Allen County in southern-central Kentucky, and urbanized Jefferson County in northern-central Kentucky. In view of the locations of the stations demonstrating positive trends, similar work in adjacent states will be required to better understand the processes responsible for those trends and to properly place them in their larger context, if any.

  13. Air pollution control systems in WtE units: An overview

    Energy Technology Data Exchange (ETDEWEB)

    Vehlow, J., E-mail: juergen.vehlow@partner.kit.edu

    2015-03-15

    Highlights: • The paper describes in brief terms the development of gas cleaning in waste incineration. • The main technologies for pollutant removal are described including their basic mechanisms. • Their respective efficiencies and their application are discussed. • A cautious outlook regarding future developments is made. - Abstract: All WtE (waste-to-energy) plants, based on combustion or other thermal processes, need an efficient gas cleaning for compliance with legislative air emission standards. The development of gas cleaning technologies started along with environment protection regulations in the late 1960s. Modern APC (air pollution control) systems comprise multiple stages for the removal of fly ashes, inorganic and organic gases, heavy metals, and dioxins from the flue gas. The main technologies and devices used for abatement of the various pollutants are described and their basic principles, their peculiarities, and their application are discussed. Few systems for cleaning of synthesis gas from waste gasification plants are included. Examples of APC designs in full scale plants are shown and cautious prospects for the future development of APC systems are made.

  14. Air pollution control systems in WtE units: An overview

    International Nuclear Information System (INIS)

    Vehlow, J.

    2015-01-01

    Highlights: • The paper describes in brief terms the development of gas cleaning in waste incineration. • The main technologies for pollutant removal are described including their basic mechanisms. • Their respective efficiencies and their application are discussed. • A cautious outlook regarding future developments is made. - Abstract: All WtE (waste-to-energy) plants, based on combustion or other thermal processes, need an efficient gas cleaning for compliance with legislative air emission standards. The development of gas cleaning technologies started along with environment protection regulations in the late 1960s. Modern APC (air pollution control) systems comprise multiple stages for the removal of fly ashes, inorganic and organic gases, heavy metals, and dioxins from the flue gas. The main technologies and devices used for abatement of the various pollutants are described and their basic principles, their peculiarities, and their application are discussed. Few systems for cleaning of synthesis gas from waste gasification plants are included. Examples of APC designs in full scale plants are shown and cautious prospects for the future development of APC systems are made

  15. Radiological safety aspects of handling plutonium

    International Nuclear Information System (INIS)

    Sundararajan, A.R.

    2016-01-01

    Department of Atomic Energy in its scheme of harnessing the nuclear energy for electrical power generation and strategic applications has given a huge role to utilization of plutonium. In the power production programme, fast reactors with plutonium as fuel are expected to play a major role. This would require establishing fuel reprocessing plants to handle both thermal and fast reactor fuels. So in the nuclear fuel cycle facilities variety of chemical, metallurgical, mechanical operations have to be carried out involving significant inventories of "2"3"9 Pu and associated radionuclides. Plutonium is the most radiotoxic radionuclide and therefore any facility handling it has to be designed and operated with utmost care. Two problems of major concern in the protection of persons working in plutonium handling facilities are the internal exposure to the operating personnel from uptake of plutonium and transplutonic nuclides as they are highly radiotoxic and the radiation exposure of hands and eye lens during fuel fabrication operations especially while handling recycled high burn up plutonium. In view of the fact that annual limit for intake is very small for "2"3"9Pu and its radiation emission characteristics are such that it is a huge challenge for the health physicists to detect Pu in air and in workers. This paper discusses the principles and practices followed in providing radiological surveillance to workers in plutonium handling areas. The challenges in protecting the workers from receiving exposures to hands and eye lens in handling high burn up plutonium are also discussed. The sites having Pu fuel cycle facilities should have trained medical staff to handle cases involving excessive intake of plutonium. (author)

  16. Torus sector handling system

    International Nuclear Information System (INIS)

    Grisham, D.L.

    1981-01-01

    A remote handling system is proposed for moving a torus sector of the accelerator from under the cryostat to a point where it can be handled by a crane and for the reverse process for a new sector. Equipment recommendations are presented, as well as possible alignment schemes. Some general comments about future remote-handling methods and the present capabilities of existing systems will also be included. The specific task to be addressed is the removal and replacement of a 425 to 450 ton torus sector. This requires a horizontal movement of approx. 10 m from a normal operating position to a point where its further transport can be accomplished by more conventional means (crane or floor transporter). The same horizontal movement is required for reinstallation, but a positional tolerance of 2 cm is required to allow reasonable fit-up for the vacuum seal from the radial frames to the torus sector. Since the sectors are not only heavy but rather tall and narrow, the transport system must provide a safe, stable, and repeatable method fo sector movement. This limited study indicates that the LAMPF-based method of transporting torus sectors offers a proven method of moving heavy items. In addition, the present state of the art in remote equipment is adequate for FED maintenance

  17. Handling of Solid Residues

    International Nuclear Information System (INIS)

    Medina Bermudez, Clara Ines

    1999-01-01

    The topic of solid residues is specifically of great interest and concern for the authorities, institutions and community that identify in them a true threat against the human health and the atmosphere in the related with the aesthetic deterioration of the urban centers and of the natural landscape; in the proliferation of vectorial transmitters of illnesses and the effect on the biodiversity. Inside the wide spectrum of topics that they keep relationship with the environmental protection, the inadequate handling of solid residues and residues dangerous squatter an important line in the definition of political and practical environmentally sustainable. The industrial development and the population's growth have originated a continuous increase in the production of solid residues; of equal it forms, their composition day after day is more heterogeneous. The base for the good handling includes the appropriate intervention of the different stages of an integral administration of residues, which include the separation in the source, the gathering, the handling, the use, treatment, final disposition and the institutional organization of the administration. The topic of the dangerous residues generates more expectation. These residues understand from those of pathogen type that are generated in the establishments of health that of hospital attention, until those of combustible, inflammable type, explosive, radio-active, volatile, corrosive, reagent or toxic, associated to numerous industrial processes, common in our countries in development

  18. AUTOMOTIVE DIESEL MAINTENANCE 1. UNIT XIV, I--MAINTAINING THE AIR SYSTEM, CUMMINS DIESEL ENGINE, II--UNIT REMOVAL--TRANSMISSION.

    Science.gov (United States)

    Human Engineering Inst., Cleveland, OH.

    THIS MODULE OF A 30-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE OPERATING PRINCIPLES AND MAINTENANCE OF THE DIESEL ENGINE AIR SYSTEM AND THE PROCEDURES FOR TRANSMISSION REMOVAL. TOPICS ARE (1) DEFINITION OF TERMS RELATED TO THE DIESEL AIR SYSTEM, (2) PRNCIPLES OF DIESEL AIR COMPRESSORS, (3) PRINCIPLES OF AIR STARTING MOTORS, (4)…

  19. Evaluation of the Vehicle Out-of-Commission Standard for Air Force Vehicle Maintenance Units.

    Science.gov (United States)

    1995-09-01

    been reduced, true performance of the unit has decreased. A study conducted by The Maryland Center for Productivity and Quality of Worklife in 1981...productivity indicators using criteria established by The Maryland Center for Productivity and Quality of Worklife study in 1981. The first conclusion was that...Results," Public Productivity and Management Review. 16: 395-402 (Summer 1993). Kaplan, Robert S. "Implementing the Balanced Scorecard at FMC

  20. Coercion from the Air: The United States Use of Airpower to Influence End of Conflict Negotiations

    Science.gov (United States)

    2017-05-25

    the Japanese population and war- making capacity combined with the shock of two atomic bombs to drive the Japanese towards...thousands of young Americans.”68 62 Richard Rhodes, The Making of the Atomic Bomb (New York, NY: Simon and Schuster, 1986), 705. 63 Ibid...States Government Printing Office, 1946), 9. 65 Rhodes, The Making of the Atomic Bomb , 740. 66 United States President,

  1. Model analyses of atmospheric mercury: present air quality and effects of transpacific transport on the United States

    Science.gov (United States)

    Lei, H.; Liang, X.-Z.; Wuebbles, D. J.; Tao, Z.

    2013-11-01

    Atmospheric mercury is a toxic air and water pollutant that is of significant concern because of its effects on human health and ecosystems. A mechanistic representation of the atmospheric mercury cycle is developed for the state-of-the-art global climate-chemistry model, CAM-Chem (Community Atmospheric Model with Chemistry). The model simulates the emission, transport, transformation and deposition of atmospheric mercury (Hg) in three forms: elemental mercury (Hg(0)), reactive mercury (Hg(II)), and particulate mercury (PHg). Emissions of mercury include those from human, land, ocean, biomass burning and volcano related sources. Land emissions are calculated based on surface solar radiation flux and skin temperature. A simplified air-sea mercury exchange scheme is used to calculate emissions from the oceans. The chemistry mechanism includes the oxidation of Hg(0) in gaseous phase by ozone with temperature dependence, OH, H2O2 and chlorine. Aqueous chemistry includes both oxidation and reduction of Hg(0). Transport and deposition of mercury species are calculated through adapting the original formulations in CAM-Chem. The CAM-Chem model with mercury is driven by present meteorology to simulate the present mercury air quality during the 1999-2001 period. The resulting surface concentrations of total gaseous mercury (TGM) are then compared with the observations from worldwide sites. Simulated wet depositions of mercury over the continental United States are compared to the observations from 26 Mercury Deposition Network stations to test the wet deposition simulations. The evaluations of gaseous concentrations and wet deposition confirm a strong capability for the CAM-Chem mercury mechanism to simulate the atmospheric mercury cycle. The general reproduction of global TGM concentrations and the overestimation on South Africa indicate that model simulations of TGM are seriously affected by emissions. The comparison to wet deposition indicates that wet deposition patterns

  2. Air liquide 1.8 K refrigeration units for CERN LHC project

    International Nuclear Information System (INIS)

    Hilbert, Benoit; Gistau-Baguer, Guy M.; Caillaud, Aurelie

    2002-01-01

    The Large Hadron Collider (LHC) will be CERN's next research instrument for high energy physics. This 27 km long circular accelerator will make intensive use of superconducting magnets, operated below 2.0 K. It will thus require high capacity refrigeration below 2.0 K. Coupled to a refrigerator providing 18 kW equivalent at 4.5 K, these systems will be able to absorb a cryogenic power of 2.4 kW at 1.8 K in nominal conditions. Air Liquide has designed one Cold Compressor System (CCS) pre-series for CERN-preceding 3 more of them (among 8 in total located around the machine). These systems, making use of cryogenic centrifugal compressors in a series arrangement coupled to room temperature screw compressors, are presented. Key components characteristics will be given

  3. Air liquide 1.8 K refrigeration units for CERN LHC project

    Science.gov (United States)

    Hilbert, Benoît; Gistau-Baguer, Guy M.; Caillaud, Aurélie

    2002-05-01

    The Large Hadron Collider (LHC) will be CERN's next research instrument for high energy physics. This 27 km long circular accelerator will make intensive use of superconducting magnets, operated below 2.0 K. It will thus require high capacity refrigeration below 2.0 K [1, 2]. Coupled to a refrigerator providing 18 kW equivalent at 4.5 K [3], these systems will be able to absorb a cryogenic power of 2.4 kW at 1.8 K in nominal conditions. Air Liquide has designed one Cold Compressor System (CCS) pre-series for CERN-preceding 3 more of them (among 8 in total located around the machine). These systems, making use of cryogenic centrifugal compressors in a series arrangement coupled to room temperature screw compressors, are presented. Key components characteristics will be given.

  4. Air-Liquide 1.8 K refrigeration units for CERN LHC project

    CERN Document Server

    Hilbert, B; Caillaud, A

    2002-01-01

    The Large Hadron Collider (LHC) will be CERN's next research instrument for high energy physics. This 27 km long circular accelerator will make intensive use of superconducting magnets, operated below 2.0 K. It will thus require high capacity refrigeration below 2.0 K. Coupled to a refrigerator providing 18 kW equivalent at 4.5 K, these systems will be able to absorb a cryogenic power of 2.4 kW at 1.8 K in nominal conditions. Air Liquide has designed one Cold Compressor System (CCS) pre-series for CERN- preceding 3 more of them (among 8 in total located around the machine). These systems, making use of cryogenic centrifugal compressors in a series arrangement coupled to room temperature screw compressors, are presented. Key components characteristics will be given. (5 refs).

  5. Complying with US and European complaint handling requirements.

    Science.gov (United States)

    Donawa, M E

    1997-09-01

    The importance of customer complaints for providing valuable information on the use of medical devices is clearly reflected in United States (US) and European quality system requirements for handling complaints. However, there are significant differences in US and European complaint handling requirements. This article will discuss those differences and methods for ensuring compliance.

  6. PND fuel handling decontamination program: specialized techniques and results

    International Nuclear Information System (INIS)

    Pan, R.; Hobbs, K.; Minnis, M.; Graham, K.

    1995-01-01

    The use of various decontamination techniques and equipment has become a critical part of Fuel Handling maintenance work at the Pickering Nuclear Station, an eight unit CANDU station located about 30 km east of Toronto. This paper presents an overview of the set up and techniques used for cleaning in the PND Fuel Handling Maintenance Facility, and the results achieved. (author)

  7. Evaluation of a seven-year air quality simulation using the Weather Research and Forecasting (WRF)/Community Multiscale Air Quality (CMAQ) models in the eastern United States.

    Science.gov (United States)

    Zhang, Hongliang; Chen, Gang; Hu, Jianlin; Chen, Shu-Hua; Wiedinmyer, Christine; Kleeman, Michael; Ying, Qi

    2014-03-01

    The performance of the Weather Research and Forecasting (WRF)/Community Multi-scale Air Quality (CMAQ) system in the eastern United States is analyzed based on results from a seven-year modeling study with a 4-km spatial resolution. For 2-m temperature, the monthly averaged mean bias (MB) and gross error (GE) values are generally within the recommended performance criteria, although temperature is over-predicted with MB values up to 2K. Water vapor at 2-m is well-predicted but significant biases (>2 g kg(-1)) were observed in wintertime. Predictions for wind speed are satisfactory but biased towards over-prediction with 0nitrate and sulfate concentrations are also well reproduced. The other unresolved PM2.5 components (OTHER) are significantly overestimated by more than a factor of two. No conclusive explanations can be made regarding the possible cause of this universal overestimation, which warrants a follow-up study to better understand this problem. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Preference Handling for Artificial Intelligence

    OpenAIRE

    Goldsmith, Judy; University of Kentucky; Junker, Ulrich; ILOG

    2009-01-01

    This article explains the benefits of preferences for AI systems and draws a picture of current AI research on preference handling. It thus provides an introduction to the topics covered by this special issue on preference handling.

  9. Building a QC Database of Meteorological Data From NASA KSC and the United States Air Force's Eastern Range

    Science.gov (United States)

    Brenton, James C.; Barbre, Robert E.; Orcutt, John M.; Decker, Ryan K.

    2018-01-01

    The National Aeronautics and Space Administration's (NASA) Marshall Space Flight Center (MSFC) Natural Environments Branch (EV44) has provided atmospheric databases and analysis in support of space vehicle design and day-of-launch operations for NASA and commercial launch vehicle programs launching from the NASA Kennedy Space Center (KSC), co-located on the United States Air Force's Eastern Range (ER) at the Cape Canaveral Air Force Station. The ER is one of the most heavily instrumented sites in the United States measuring various atmospheric parameters on a continuous basis. An inherent challenge with the large databases that EV44 receives from the ER consists of ensuring erroneous data are removed from the databases, and thus excluded from launch vehicle design analyses. EV44 has put forth great effort in developing quality control (QC) procedures for individual meteorological instruments; however, no standard QC procedures for all databases currently exist resulting in QC databases that have inconsistencies in variables, methodologies, and periods of record. The goal of this activity is to use the previous efforts by EV44 to develop a standardized set of QC procedures from which to build flags within the meteorological databases from KSC and the ER, while maintaining open communication with end users from the launch community to develop ways to improve, adapt and grow the QC database. Details of the QC checks are described. The flagged data points will be plotted in a graphical user interface (GUI) as part of a manual confirmation that the flagged data do indeed need to be removed from the archive. As the rate of launches increases with additional launch vehicle programs, more emphasis is being placed to continually update and check weather databases for data quality before use in launch vehicle design and certification analyses.

  10. Particulate Air Pollution, Exceptional Aging, and Rates of Centenarians: A Nationwide Analysis of the United States, 1980-2010.

    Science.gov (United States)

    Baccarelli, Andrea A; Hales, Nick; Burnett, Richard T; Jerrett, Michael; Mix, Carter; Dockery, Douglas W; Pope, C Arden

    2016-11-01

    Exceptional aging, defined as reaching age 85 years, shows geographic inequalities that may depend on local environmental conditions. Links between particulate pollution-a well-recognized environmental risk factor-and exceptional aging have not been investigated. We conducted a nationwide analysis of ~28 million adults in 3,034 United States counties to determine whether local PM2.5 levels (particulate matter migration variables. On average, 2,295 and 71.4 per 10,000 of the 55- to 64- and 70- to 74-year-olds in 1980, respectively, remained in the 85- to 94- and 100- to 104-year-old population in 2010. An interquartile range (4.19 μg/m3) increase in PM2.5 was associated with 93.7 fewer 85- to 94-year-olds (p national standard. Exceptional aging was strongly associated with smoking, with an interquartile range (4.77%) increase in population who smoked associated with 181.9 fewer 85- to 94-year-olds (p income. Communities with the most exceptional aging have low ambient air pollution and low rates of smoking, poverty, and obesity. Improvements in these determinants may contribute to increasing exceptional aging. Citation: Baccarelli AA, Hales N, Burnett RT, Jerrett M, Mix C, Dockery DW, Pope CA III. 2016. Particulate air pollution, exceptional aging, and rates of centenarians: a nationwide analysis of the United States, 1980-2010. Environ Health Perspect 124:1744-1750; http://dx.doi.org/10.1289/EHP197.

  11. Crud handling circuit

    International Nuclear Information System (INIS)

    Smith, J.C.; Manuel, R.J.; McAllister, J.E.

    1981-01-01

    A process for handling the problems of crud formation during the solvent extraction of wet-process phosphoric acid, e.g. for uranium and rare earth removal, is described. It involves clarification of the crud-solvent mixture, settling, water washing the residue and treatment of the crud with a caustic wash to remove and regenerate the solvent. Applicable to synergistic mixtures of dialkylphosphoric acids and trialkylphosphine oxides dissolved in inert diluents and more preferably to the reductive stripping technique. (U.K.)

  12. Handling of potassium

    International Nuclear Information System (INIS)

    Schwarz, N.; Komurka, M.

    1983-03-01

    As a result for the Fast Breeder Development extensive experience is available worldwide with respect to Sodium technology. Due to the extension of the research program to topping cycles with Potassium as the working medium, test facilities with Potassium have been designed and operated in the Institute of Reactor Safety. The different chemical properties of Sodium and Potassium give rise in new safety concepts and operating procedures. The handling problems of Potassium are described in the light of theoretical properties and own experiences. Selected literature on main safety and operating problems complete this report. (Author) [de

  13. Mitigating an increase of specific power consumption in a cryogenic air separation unit at reduced oxygen production

    Science.gov (United States)

    Singla, Rohit; Chowdhury, Kanchan

    2017-02-01

    Specific power consumed in a Linde double column air separation unit (ASU) increases as the quantity of oxygen produced at a given purity is decreased due to the changes of system requirement or market demand. As the plant operates in part load condition, the specific power consumption (SPC) increases as the total power consumption remains the same. In order to mitigate the increase of SPC at lower oxygen production, the operating pressure of high pressure column (HPC) can be lowered by extending the low pressure column (LPC) by a few trays and adding a second reboiler. As the duty of second reboiler in LPC is increased, the recovery of oxygen decreases with a lowering of the HPC pressure. This results in mitigation of the increase of SPC of the plant. A Medium pressure ASU with dual reboiler that produces pressurised gaseous and liquid products of oxygen and nitrogen is simulated in Aspen Hysys 8.6®, a commercial process simulator to determine SPC at varying oxygen production. The effects of reduced pressure of air feed into the cold box on the size of heat exchangers (HX) are analysed. Operation strategy to obtain various oxygen production rates at varying demand is also proposed.

  14. Effects of El Niño on Summertime Ozone Air Quality in the Eastern United States

    Science.gov (United States)

    Shen, Lu; Mickley, Loretta J.

    2017-12-01

    We investigate the effect of El Niño on maximum daily 8 h average surface ozone over the eastern United States in summer during 1980-2016. El Niño can influence the extratropical climate through the propagation of stationary waves, leading to (1) reduced transport of moist, clean air into the middle and southern Atlantic states and greater subsidence, reduced precipitation, and increased surface solar radiation in this region, as well as (2) intensified southerly flow into the south central states, which here enhances flux of moist and clean air. As a result, each standard deviation increase in the Niño 1 + 2 index is associated with an increase of 1-2 ppbv ozone in the Atlantic states and a decrease of 0.5-2 ppbv ozone in the south central states. These influences can be predicted 4 months in advance. We show that U.S. summertime ozone responds differently to eastern-type El Niño events compared to central-type events.

  15. Passivity-Based Control for a Micro Air Vehicle Using Unit Quaternions

    Directory of Open Access Journals (Sweden)

    Maria Eusebia Guerrero-Sanchez

    2016-12-01

    Full Text Available In this paper the development and practical implementation of a Passivity-Based Control (PBC algorithm to stabilize an Unmanned Aerial Vehicle (UAV described with unit quaternions are presented. First, a mathematical model based on Euler-Lagrange formulation using a logarithmic mapping in the quaternion space is introduced. Then, a new methodology: a quaternion-passivity-based control is derived, which does not compute excessive and complex Partial Differential Equations (PDEs for synthesizing the control law, making a significant advantage in comparison with other methodologies. Therefore, the control design to a system as the quad-rotor is easily solved by the proposed methodology. Another advantage is the possibility to stabilize quad-rotor full dynamics which may not be possible with classical PBC techniques. Experimental results and numerical simulations to validate our proposed scheme are presented.

  16. Cooper-Harper Experience Report for Spacecraft Handling Qualities Applications

    Science.gov (United States)

    Bailey, Randall E.; Jackson, E. Bruce; Bilimoria, Karl D.; Mueller, Eric R.; Frost, Chad R.; Alderete, Thomas S.

    2009-01-01

    A synopsis of experience from the fixed-wing and rotary-wing aircraft communities in handling qualities development and the use of the Cooper-Harper pilot rating scale is presented as background for spacecraft handling qualities research, development, test, and evaluation (RDT&E). In addition, handling qualities experiences and lessons-learned from previous United States (US) spacecraft developments are reviewed. This report is intended to provide a central location for references, best practices, and lessons-learned to guide current and future spacecraft handling qualities RDT&E.

  17. Air, hand wipe, and surface wipe sampling for Bisphenol A (BPA) among workers in industries that manufacture and use BPA in the United States.

    Science.gov (United States)

    Hines, Cynthia J; Jackson, Matthew V; Christianson, Annette L; Clark, John C; Arnold, James E; Pretty, Jack R; Deddens, James A

    2017-11-01

    For decades, bisphenol A (BPA) has been used in making polycarbonate, epoxy, and phenolic resins and certain investment casting waxes, yet published exposure data are lacking for U.S. manufacturing workers. In 2013-2014, BPA air and hand exposures were quantified for 78 workers at six U.S. companies making BPA or BPA-based products. Exposure measures included an inhalable-fraction personal air sample on each of two consecutive work days (n = 146), pre- and end-shift hand wipe samples on the second day (n = 74 each), and surface wipe samples (n = 88). Potential determinants of BPA air and end-shift hand exposures (after natural log transformation) were assessed in univariate and multiple regression mixed models. The geometric mean (GM) BPA air concentration was 4.0 µg/m 3 (maximum 920 µg/m 3 ). The end-shift GM BPA hand level (26 µg/sample) was 10-times higher than the pre-shift level (2.6 µg/sample). BPA air and hand exposures differed significantly by industry and job. BPA air concentrations and end-shift hand levels were highest in the BPA-filled wax manufacturing/reclaim industry (GM Air = 48 µg/m 3 , GM Hand-End = 130 µg/sample) and in the job of working with molten BPA-filled wax (GM Air = 43 µg/m 3 , GM Hand-End = 180 µg/sample), and lowest in the phenolic resins industry (GM Air = 0.85 µg/m 3 , GM Hand-End = 0.43 µg/sample) and in the job of flaking phenolic resins (GM AIR = 0.62 µg/m 3 , GM Hand-End = 0.38 µg/sample). Determinants of increased BPA air concentration were industry, handling BPA containers, spilling BPA, and spending ≥50% of the shift in production areas; increasing age was associated with lower air concentrations. BPA hand exposure determinants were influenced by high values for two workers; for all other workers, tasks involving contact with BPA-containing materials and spending ≥50% of the shift in production areas were associated with increased BPA hand levels. Surface wipe BPA levels were significantly lower in

  18. Cooperation of Horizontal Ground Heat Exchanger with the Ventilation Unit During Summer - Case Study

    Science.gov (United States)

    Romańska-Zapała, Anna; Furtak, Marcin; Dechnik, Mirosław

    2017-10-01

    Renewable energy sources are used in the modern energy-efficient buildings to improve their energy balance. One of them is used in the mechanical ventilation system ground air heat exchanger (earth-air heat exchanger - EAHX). This solution, right after heat recovery from exhaust air (recuperation), allows the reduction in the energy needed to obtain the desired temperature of supply air. The article presents the results of "in situ" measurements of pipe ground air heat exchanger cooperating with the air handling unit, supporting cooling the building in the summer season, in Polish climatic conditions. The laboratory consists of a ventilation unit intake - exhaust with rotor for which the source of fresh air is the air intake wall and two air intakes field cooperating with the tube with ground air heat exchangers. Selection of the source of fresh air is performed using sprocket with actuators. This system is part of the ventilation system of the Malopolska Laboratory of Energy-Efficient Building (MLBE) building of Cracow University of Technology. The measuring system are, among others, the sensors of parameters of air inlets and outlets of the heat exchanger channels EAHX and weather station that senses the local weather conditions. The measurement data are recorded and archived by the integrated process control system in the building of MLBE. During the study measurements of operating parameters of the ventilation unit cooperating with the selected source of fresh air were performed. Two cases of operation of the system: using EAHX heat exchanger and without it, were analyzed. Potentially the use of ground air heat exchanger in the mechanical ventilation system can reduce the energy demand for heating or cooling rooms by the pre-adjustment of the supply air temperature. Considering the results can be concluded that the continuous use of these exchangers is not optimal. This relationship is appropriate not only on an annual basis for the transitional periods (spring

  19. The optimum intermediate pressure of two-stages vapor compression refrigeration cycle for Air-Conditioning unit

    Science.gov (United States)

    Ambarita, H.; Sihombing, H. V.

    2018-03-01

    Vapor compression cycle is mainly employed as a refrigeration cycle in the Air-Conditioning (AC) unit. In order to save energy, the Coefficient of Performance (COP) of the need to be improved. One of the potential solutions is to modify the system into multi-stages vapor compression cycle. The suitable intermediate pressure between the high and low pressures is one of the design issues. The present work deals with the investigation of an optimum intermediate pressure of two-stages vapor compression refrigeration cycle. Typical vapor compression cycle that is used in AC unit is taken into consideration. The used refrigerants are R134a. The governing equations have been developed for the systems. An inhouse program has been developed to solve the problem. COP, mass flow rate of the refrigerant and compressor power as a function of intermediate pressure are plotted. It was shown that there exists an optimum intermediate pressure for maximum COP. For refrigerant R134a, the proposed correlations need to be revised.

  20. Air Quality System (AQS)

    Science.gov (United States)

    The Air Quality System (AQS) database contains measurements of air pollutant concentrations from throughout the United States and its territories. The measurements include both criteria air pollutants and hazardous air pollutants.

  1. AirData

    Data.gov (United States)

    U.S. Environmental Protection Agency — The AirData site provides access to yearly summaries of United States air pollution data, taken from EPA's air pollution databases. AirData has information about...

  2. Rural and Urban Differences in Air Quality, 2008-2012, and Community Drinking Water Quality, 2010-2015 - United States.

    Science.gov (United States)

    Strosnider, Heather; Kennedy, Caitlin; Monti, Michele; Yip, Fuyuen

    2017-06-23

    The places in which persons live, work, and play can contribute to the development of adverse health outcomes. Understanding the differences in risk factors in various environments can help to explain differences in the occurrence of these outcomes and can be used to develop public health programs, interventions, and policies. Efforts to characterize urban and rural differences have largely focused on social and demographic characteristics. A paucity of national standardized environmental data has hindered efforts to characterize differences in the physical aspects of urban and rural areas, such as air and water quality. 2008-2012 for air quality and 2010-2015 for water quality. Since 2002, CDC's National Environmental Public Health Tracking Program has collaborated with federal, state, and local partners to gather standardized environmental data by creating national data standards, collecting available data, and disseminating data to be used in developing public health actions. The National Environmental Public Health Tracking Network (i.e., the tracking network) collects data provided by national, state, and local partners and includes 21 health outcomes, exposures, and environmental hazards. To assess environmental factors that affect health, CDC analyzed three air-quality measures from the tracking network for all counties in the contiguous United States during 2008-2012 and one water-quality measure for 26 states during 2010-2015. The three air-quality measures include 1) total number of days with fine particulate matter (PM 2.5 ) levels greater than the U.S. Environmental Protection Agency's (EPA's) National Ambient Air Quality Standards (NAAQS) for 24-hour average PM 2.5 (PM 2.5 days); 2) mean annual average ambient concentrations of PM 2.5 in micrograms per cubic meter (mean PM 2.5 ); and 3) total number of days with maximum 8-hour average ozone concentrations greater than the NAAQS (ozone days). The water-quality measure compared the annual mean

  3. MFTF exception handling system

    International Nuclear Information System (INIS)

    Nowell, D.M.; Bridgeman, G.D.

    1979-01-01

    In the design of large experimental control systems, a major concern is ensuring that operators are quickly alerted to emergency or other exceptional conditions and that they are provided with sufficient information to respond adequately. This paper describes how the MFTF exception handling system satisfies these requirements. Conceptually exceptions are divided into one of two classes. Those which affect command status by producing an abort or suspend condition and those which fall into a softer notification category of report only or operator acknowledgement requirement. Additionally, an operator may choose to accept an exception condition as operational, or turn off monitoring for sensors determined to be malfunctioning. Control panels and displays used in operator response to exceptions are described

  4. Plutonium safe handling

    International Nuclear Information System (INIS)

    Tvehlov, Yu.

    2000-01-01

    The abstract, prepared on the basis of materials of the IAEA new leadership on the plutonium safe handling and its storage (the publication no. 9 in the Safety Reports Series), aimed at presenting internationally acknowledged criteria on the radiation danger evaluation and summarizing the experience in the safe management of great quantities of plutonium, accumulated in the nuclear states, is presented. The data on the weapon-class and civil plutonium, the degree of its danger, the measures for provision of its safety, including the data on accident radiation consequences with the fission number 10 18 , are presented. The recommendations, making it possible to eliminate the super- criticality danger, as well as ignition and explosion, to maintain the tightness of the facility, aimed at excluding the radioactive contamination and the possibility of internal irradiation, to provide for the plutonium security, physical protection and to reduce irradiation are given [ru

  5. Measuring instruments of the Physikalisch-Technische Bundesanstalt for realization of the units of the dosimetric quantities standard ion dose, photon-equivalent dose and air-kerma

    International Nuclear Information System (INIS)

    Engelke, B.A.; Oetzmann, W.; Struppek, G.

    1988-08-01

    The realization of the units of the dosimetric quantities exposure, air-kerma and photon-equivalent dose is an important task of the Physikalisch-Technische Bundesanstalt. The report describes the measuring instruments and other technical equipment as well as the determination of the numerous corrections needed. All data and correction factors required for the realization of the units mentioned above are given in many diagrams and tables. (orig.) [de

  6. Summer Research Program - 1997 Summer Faculty Research Program Volume 6 Arnold Engineering Development Center United States Air Force Academy Air Logistics Centers

    Science.gov (United States)

    1997-12-01

    Fracture Analysis of the F-5, 15%-Spar Bolt DR Devendra Kumar SAALC/LD 6- 16 CUNY-City College, New York, NY A Simple, Multiversion Concurrency Control...Program, University of Dayton, Dayton, OH. [3]AFGROW, Air Force Crack Propagation Analysis Program, Version 3.82 (1997) 15-8 A SIMPLE, MULTIVERSION ...Office of Scientific Research Boiling Air Force Base, DC and San Antonio Air Logistic Center August 1997 16-1 A SIMPLE, MULTIVERSION CONCURRENCY

  7. Demonstration of Intelligent Control and Fan Improvements in Computer Room Air Handlers

    Energy Technology Data Exchange (ETDEWEB)

    Coles, Henry [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division; Greenberg, Steve [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Environmental Energy Technologies Division; Vita, Corinne [Vigilent, Oakland, CA (United States)

    2012-11-30

    This report documents a demonstration of the energy-efficiency improvement provided by a new control system for computer room air handling devices. It also analyzes measured and reported air handling device fan power associated with changing the fan type. A 135,000 square foot commercial data center was used for the demonstration. All air handling units were upgraded with improved efficiency fans, and a control system that automatically adjusts the fan speed for the air handling units was added. Power measurements were collected for a baseline and for a period with the fan speed control system active. Changing the fan type resulted in a savings of 47 percent of energy used by the air handling equipment and associated chiller plant energy needed to cool the air handlers themselves. The addition of the fan speed control resulted in an additional 37 percent savings in the same two categories. The combined savings for the two improvements for the same categories was 66 percent compared to the data center fitted with the original fans without a control system. The energy use reduction provided by the complete air handling device improvement program for the whole data center site is estimated to be 2.9 million kilowatt hours per year—an overall data center site savings of 8.0 percent. The reduced electrical energy use at the site provides a 1.9 million pound yearly reduction of carbon dioxide emissions. This demonstration showed that fan upgrades and a control system addition provide cost-effective improvements for data centers, with a payback reported to be under two years without utility incentives. In addition to the control system providing energy savings, the data collection and visual analysis capabilities provided immediate and long-term benefits. It is recommended that data center operators consider investing in fan upgrades and/or adding fan speed control for computer room air handlers.

  8. Development of ZL400 Mine Cooling Unit Using Semi-Hermetic Screw Compressor and Its Application on Local Air Conditioning in Underground Long-Wall Face

    Science.gov (United States)

    Chu, Zhaoxiang; Ji, Jianhu; Zhang, Xijun; Yan, Hongyuan; Dong, Haomin; Liu, Junjie

    2016-12-01

    Aiming at heat injuries occurring in the process of deep coal mining in China, a ZL400 mine-cooling unit employing semi-hermetic screw compressor with a cooling capacity of 400 kW is developed. This paper introduced its operating principle, structural characteristics and technical indexes. By using the self-built testing platform, some parameters for indication of its operation conditions were tested on the ground. The results show that the aforementioned cooling unit is stable in operation: cooling capacity of the unit was 420 kW underground-test conditions, while its COP (coefficient of performance) reached 3.4. To address the issue of heat injuries existing in No. 16305 U-shaped long-wall ventilation face of Jining No. 3 coal mine, a local air conditioning system was developed with ZL400 cooling unit as the system's core. The paper presented an analysis of characteristics of the air current flowing in the air-mixing and cooling mode of ZL400 cooling unit used in air intake way. Through i-d patterns we described the process of the airflow treatment, such as cooling, mixing and heating, etc. The cooling system decreased dry bulb temperature on working face by 3°C on average and 3.8°C at most, while lowered the web bulb temperature by 3.6°C on average and 4.8°C at most. At the same time, it reduced relative humidity by 5% on average and 8.6% at most. The field application of the ZL400 cooling unit had gain certain effects in air conditioning and provided support for the solution of mine heat injuries in China in terms of technology and equipment.

  9. Air pollution and early deaths in the United States. Part I: Quantifying the impact of major sectors in 2005

    Science.gov (United States)

    Caiazzo, Fabio; Ashok, Akshay; Waitz, Ian A.; Yim, Steve H. L.; Barrett, Steven R. H.

    2013-11-01

    Combustion emissions adversely impact air quality and human health. A multiscale air quality model is applied to assess the health impacts of major emissions sectors in United States. Emissions are classified according to six different sources: electric power generation, industry, commercial and residential sources, road transportation, marine transportation and rail transportation. Epidemiological evidence is used to relate long-term population exposure to sector-induced changes in the concentrations of PM2.5 and ozone to incidences of premature death. Total combustion emissions in the U.S. account for about 200,000 (90% CI: 90,000-362,000) premature deaths per year in the U.S. due to changes in PM2.5 concentrations, and about 10,000 (90% CI: -1000 to 21,000) deaths due to changes in ozone concentrations. The largest contributors for both pollutant-related mortalities are road transportation, causing ∼53,000 (90% CI: 24,000-95,000) PM2.5-related deaths and ∼5000 (90% CI: -900 to 11,000) ozone-related early deaths per year, and power generation, causing ∼52,000 (90% CI: 23,000-94,000) PM2.5-related and ∼2000 (90% CI: -300 to 4000) ozone-related premature mortalities per year. Industrial emissions contribute to ∼41,000 (90% CI: 18,000-74,000) early deaths from PM2.5 and ∼2000 (90% CI: 0-4000) early deaths from ozone. The results are indicative of the extent to which policy measures could be undertaken in order to mitigate the impact of specific emissions from different sectors - in particular black carbon emissions from road transportation and sulfur dioxide emissions from power generation.

  10. Fuel handling grapple for nuclear reactor plants

    International Nuclear Information System (INIS)

    Rousar, D.L.

    1992-01-01

    This patent describes a fuel handling system for nuclear reactor plants. It comprises: a reactor vessel having an openable top and removable cover and containing therein, submerged in water substantially filling the reactor vessel, a fuel core including a multiplicity of fuel bundles formed of groups of sealed tube elements enclosing fissionable fuel assembled into units, the fuel handling system consisting essentially of the combination of: a fuel bundle handling platform movable over the open top of the reactor vessel; a fuel bundle handling mast extendable downward from the platform with a lower end projecting into the open top reactor vessel to the fuel core submerged in water; a grapple head mounted on the lower end of the mast provided with grapple means comprising complementary hooks which pivot inward toward each other to securely grasp a bail handle of a nuclear reactor fuel bundle and pivot backward away from each other to release a bail handle; the grapple means having a hollow cylindrical support shaft fixed within the grapple head with hollow cylindrical sleeves rotatably mounted and fixed in longitudinal axial position on the support shaft and each sleeve having complementary hooks secured thereto whereby each hook pivots with the rotation of the sleeve secured thereto; and the hollow cylindrical support shaft being provided with complementary orifices on opposite sides of its hollow cylindrical and intermediate to the sleeves mounted thereon whereby the orifices on both sides of the hollow cylindrical support shaft are vertically aligned providing a direct in-line optical viewing path downward there-through and a remote operator positioned above the grapple means can observe from overhead the area immediately below the grapple hooks

  11. Air quality and exercise-related health benefits from reduced car travel in the midwestern United States.

    Science.gov (United States)

    Grabow, Maggie L; Spak, Scott N; Holloway, Tracey; Stone, Brian; Mednick, Adam C; Patz, Jonathan A

    2012-01-01

    Automobile exhaust contains precursors to ozone and fine particulate matter (PM ≤ 2.5 µm in aerodynamic diameter; PM2.5), posing health risks. Dependency on car commuting also reduces physical fitness opportunities. In this study we sought to quantify benefits from reducing automobile usage for short urban and suburban trips. We simulated census-tract level changes in hourly pollutant concentrations from the elimination of automobile round trips ≤ 8 km in 11 metropolitan areas in the upper midwestern United States using the Community Multiscale Air Quality (CMAQ) model. Next, we estimated annual changes in health outcomes and monetary costs expected from pollution changes using the U.S. Environmental Protection Agency Benefits Mapping Analysis Program (BenMAP). In addition, we used the World Health Organization Health Economic Assessment Tool (HEAT) to calculate benefits of increased physical activity if 50% of short trips were made by bicycle. We estimate that, by eliminating these short automobile trips, annual average urban PM2.5 would decline by 0.1 µg/m3 and that summer ozone (O3) would increase slightly in cities but decline regionally, resulting in net health benefits of $4.94 billion/year [95% confidence interval (CI): $0.2 billion, $13.5 billion), with 25% of PM2.5 and most O3 benefits to populations outside metropolitan areas. Across the study region of approximately 31.3 million people and 37,000 total square miles, mortality would decline by approximately 1,295 deaths/year (95% CI: 912, 1,636) because of improved air quality and increased exercise. Making 50% of short trips by bicycle would yield savings of approximately $3.8 billion/year from avoided mortality and reduced health care costs (95% CI: $2.7 billion, $5.0 billion]. We estimate that the combined benefits of improved air quality and physical fitness would exceed $8 billion/year. Our findings suggest that significant health and economic benefits are possible if bicycling replaces short

  12. A versatile, refrigerant- and cryogen-free cryofocusing–thermodesorption unit for preconcentration of traces gases in air

    Directory of Open Access Journals (Sweden)

    F. Obersteiner

    2016-10-01

    Full Text Available We present a compact and versatile cryofocusing–thermodesorption unit, which we developed for quantitative analysis of halogenated trace gases in ambient air. Possible applications include aircraft-based in situ measurements, in situ monitoring and laboratory operation for the analysis of flask samples. Analytes are trapped on adsorptive material cooled by a Stirling cooler to low temperatures (e.g. −80 °C and subsequently desorbed by rapid heating of the adsorptive material (e.g. +200 °C. The set-up involves neither the exchange of adsorption tubes nor any further condensation or refocusing steps. No moving parts are used that would require vacuum insulation. This allows for a simple and robust design. Reliable operation is ensured by the Stirling cooler, which neither contains a liquid refrigerant nor requires refilling a cryogen. At the same time, it allows for significantly lower adsorption temperatures compared to commonly used Peltier elements. We use gas chromatography – mass spectrometry (GC–MS for separation and detection of the preconcentrated analytes after splitless injection. A substance boiling point range of approximately −80 to +150 °C and a substance mixing ratio range of less than 1 ppt (pmol mol−1 to more than 500 ppt in preconcentrated sample volumes of 0.1 to 10 L of ambient air is covered, depending on the application and its analytical demands. We present the instrumental design of the preconcentration unit and demonstrate capabilities and performance through the examination of analyte breakthrough during adsorption, repeatability of desorption and analyte residues in blank tests. Examples of application are taken from the analysis of flask samples collected at Mace Head Atmospheric Research Station in Ireland using our laboratory GC–MS instruments and by data obtained during a research flight with our in situ aircraft instrument GhOST-MS (Gas chromatograph for the Observation of Tracers

  13. Assessment of microbiological air quality in hemato-oncology units and its relationship with the occurrence of invasive fungal infections: an integrative review

    Directory of Open Access Journals (Sweden)

    Mayra Goncalves Menegueti

    2013-07-01

    Full Text Available Worldwide aging of the human population has promoted an increase in the incidence of neoplasia, including hematological cancers, which render patients particularly vulnerable to invasive fungal infections. For this reason, air filtration in hemato-oncology units has been recommended. However, scarce literature has assessed the impact of microbiological air quality on the occurrence of fungal infections in this population. We performed an integrative review of studies in the MEDLINE database that were published between January 1980 and October 2012, using the following combinations of keywords: air × quality × HEPA, air × quality × hematology, and airborne fungal infections. The search yielded only 13 articles, suggesting that high-efficiency filtering of the ambient air in hemato-oncology units can prevent the incidence of invasive fungal infections. However, no randomized clinical trial was found to confirm this suggestion. Currently, there is no consensus about the maximum allowable count of fungi in the air, which complicates filtration monitoring, including filter maintenance and replacement, and needs to be addressed in future studies.

  14. Integrated sampling and analysis unit for the determination of sexual pheromones in environmental air using fabric phase sorptive extraction and headspace-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Alcudia-León, M Carmen; Lucena, Rafael; Cárdenas, Soledad; Valcárcel, Miguel; Kabir, Abuzar; Furton, Kenneth G

    2017-03-10

    This article presents a novel unit that integrates for the first time air sampling and preconcentration based on the use of fabric phase sorptive extraction principles. The determination of Tuta absoluta sexual pheromone traces in environmental air has been selected as analytical problem. For this aim, a novel laboratory-built unit made up of commercial brass elements as holder of the sol-gel coated fabric extracting phase has been designed and optimized. The performance of the integrated unit was evaluated analyzing environmental air sampled in tomato crops. The unit can work under sampling and analysis mode which eliminates any need for sorptive phase manipulation prior to instrumental analysis. In the sampling mode, the unit can be connected to a sampling pump to pass the air through the sorptive phase at a controlled flow-rate. In the analysis mode, it is placed in the gas chromatograph autosampler without any instrumental modification. It also diminishes the risk of cross contamination between sampling and analysis. The performance of the new unit has been evaluated using the main components of the sexual pheromone of Tuta absoluta [(3E,8Z,11Z)-tetradecatrien-1-yl acetate and (3E,8Z)-tetradecadien-1-yl acetate] as model analytes. The limits of detection for both compounds resulted to be 1.6μg and 0.8μg, respectively, while the precision (expressed as relative standard deviation) was better than 3.7%. Finally, the unit has been deployed in the field to analyze a number of real life samples, some of them were found positive. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Unvented Drum Handling Plan

    International Nuclear Information System (INIS)

    MCDONALD, K.M.

    2000-01-01

    This drum-handling plan proposes a method to deal with unvented transuranic drums encountered during retrieval of drums. Finding unvented drums during retrieval activities was expected, as identified in the Transuranic (TRU) Phase I Retrieval Plan (HNF-4781). However, significant numbers of unvented drums were not expected until excavation of buried drums began. This plan represents accelerated planning for management of unvented drums. A plan is proposed that manages unvented drums differently based on three categories. The first category of drums is any that visually appear to be pressurized. These will be vented immediately, using either the Hanford Fire Department Hazardous Materials (Haz. Mat.) team, if such are encountered before the facilities' capabilities are established, or using internal capabilities, once established. To date, no drums have been retrieved that showed signs of pressurization. The second category consists of drums that contain a minimal amount of Pu isotopes. This minimal amount is typically less than 1 gram of Pu, but may be waste-stream dependent. Drums in this category are assayed to determine if they are low-level waste (LLW). LLW drums are typically disposed of without venting. Any unvented drums that assay as TRU will be staged for a future venting campaign, using appropriate safety precautions in their handling. The third category of drums is those for which records show larger amounts of Pu isotopes (typically greater than or equal to 1 gram of Pu). These are assumed to be TRU and are not assayed at this point, but are staged for a future venting campaign. Any of these drums that do not have a visible venting device will be staged awaiting venting, and will be managed under appropriate controls, including covering the drums to protect from direct solar exposure, minimizing of container movement, and placement of a barrier to restrict vehicle access. There are a number of equipment options available to perform the venting. The

  16. New transport and handling contract

    CERN Multimedia

    SC Department

    2008-01-01

    A new transport and handling contract entered into force on 1.10.2008. As with the previous contract, the user interface is the internal transport/handling request form on EDH: https://edh.cern.ch/Document/TransportRequest/ To ensure that you receive the best possible service, we invite you to complete the various fields as accurately as possible and to include a mobile telephone number on which we can reach you. You can follow the progress of your request (schedule, completion) in the EDH request routing information. We remind you that the following deadlines apply: 48 hours for the transport of heavy goods (up to 8 tonnes) or simple handling operations 5 working days for crane operations, transport of extra-heavy goods, complex handling operations and combined transport and handling operations in the tunnel. For all enquiries, the number to contact remains unchanged: 72202. Heavy Handling Section TS-HE-HH 72672 - 160319

  17. Solution for remote handling in accelerator installations

    International Nuclear Information System (INIS)

    Burgerjon, J.J.; Ekberg, E.L.; Grisham, D.L.; Horne, R.A.; Meyer, R.E.; Flatau, C.R.; Wilson, K.B.

    1977-01-01

    A description is given of a remote-handling system designed for the Los Alamos Clinton P. Anderson Meson Physics Facility (LAMPF), versatile enough to be used in a variety of situations found around particle accelerators. The system consists of a bilateral (force-reflecting) servomanipulator installed on an articulated hydraulic boom. The boom also carries the necessary tools and observation devices. The whole slave unit can be moved by crane or truck to the area of operation. A control cable connects the slave unit with the control station, located at a safe distance in a trailer. Various stages of development as well as some operating experience are discussed

  18. A robust model predictive control strategy for improving the control performance of air-conditioning systems

    International Nuclear Information System (INIS)

    Huang Gongsheng; Wang Shengwei; Xu Xinhua

    2009-01-01

    This paper presents a robust model predictive control strategy for improving the supply air temperature control of air-handling units by dealing with the associated uncertainties and constraints directly. This strategy uses a first-order plus time-delay model with uncertain time-delay and system gain to describe air-conditioning process of an air-handling unit usually operating at various weather conditions. The uncertainties of the time-delay and system gain, which imply the nonlinearities and the variable dynamic characteristics, are formulated using an uncertainty polytope. Based on this uncertainty formulation, an offline LMI-based robust model predictive control algorithm is employed to design a robust controller for air-handling units which can guarantee a good robustness subject to uncertainties and constraints. The proposed robust strategy is evaluated in a dynamic simulation environment of a variable air volume air-conditioning system in various operation conditions by comparing with a conventional PI control strategy. The robustness analysis of both strategies under different weather conditions is also presented.

  19. Remote handling and accelerators

    International Nuclear Information System (INIS)

    Wilson, M.T.

    1983-01-01

    The high-current levels of contemporary and proposed accelerator facilities induce radiation levels into components, requiring consideration be given to maintenance techniques that reduce personnel exposure. Typical components involved include beamstops, targets, collimators, windows, and instrumentation that intercepts the direct beam. Also included are beam extraction, injection, splitting, and kicking regions, as well as purposeful spill areas where beam tails are trimmed and neutral particles are deposited. Scattered beam and secondary particles activate components all along a beamline such as vacuum pipes, magnets, and shielding. Maintenance techniques vary from hands-on to TV-viewed operation using state-of-the-art servomanipulators. Bottom- or side-entry casks are used with thimble-type target and diagnostic assemblies. Long-handled tools are operated from behind shadow shields. Swinging shield doors, unstacking block, and horizontally rolling shield roofs are all used to provide access. Common to all techniques is the need to make operations simple and to provide a means of seeing and reaching the area

  20. TFTR tritium handling concepts

    International Nuclear Information System (INIS)

    Garber, H.J.

    1976-01-01

    The Tokamak Fusion Test Reactor, to be located on the Princeton Forrestal Campus, is expected to operate with 1 to 2.5 MA tritium--deuterium plasmas, with the pulses involving injection of 50 to 150 Ci (5 to 16 mg) of tritium. Attainment of fusion conditions is based on generation of an approximately 1 keV tritium plasma by ohmic heating and conversion to a moderately hot tritium--deuterium ion plasma by injection of a ''preheating'' deuterium neutral beam (40 to 80 keV), followed by injection of a ''reacting'' beam of high energy neutral deuterium (120 to 150 keV). Additionally, compressions accompany the beam injections. Environmental, safety and cost considerations led to the decision to limit the amount of tritium gas on-site to that required for an experiment, maintaining all other tritium in ''solidified'' form. The form of the tritium supply is as uranium tritide, while the spent tritium and other hydrogen isotopes are getter-trapped by zirconium--aluminum alloy. The issues treated include: (1) design concepts for the tritium generator and its purification, dispensing, replenishment, containment, and containment--cleanup systems; (2) features of the spent plasma trapping system, particularly the regenerable absorption cartridges, their integration into the vacuum system, and the handling of non-getterables; (3) tritium permeation through the equipment and the anticipated releases to the environment; (4) overview of the tritium related ventilation systems; and (5) design bases for the facility's tritium clean-up systems

  1. Safe Handling of Radioisotopes

    International Nuclear Information System (INIS)

    1958-01-01

    Under its Statute the International Atomic Energy Agency is empowered to provide for the application of standards of safety for protection against radiation to its own operations and to operations making use of assistance provided by it or with which it is otherwise directly associated. To this end authorities receiving such assistance are required to observe relevant health and safety measures prescribed by the Agency. As a first step, it has been considered an urgent task to provide users of radioisotopes with a manual of practice for the safe handling of these substances. Such a manual is presented here and represents the first of a series of manuals and codes to be issued by the Agency. It has been prepared after careful consideration of existing national and international codes of radiation safety, by a group of international experts and in consultation with other international bodies. At the same time it is recommended that the manual be taken into account as a basic reference document by Member States of the Agency in the preparation of national health and safety documents covering the use of radioisotopes.

  2. Radioactive wastes handling facility

    International Nuclear Information System (INIS)

    Hirose, Emiko; Inaguma, Masahiko; Ozaki, Shigeru; Matsumoto, Kaname.

    1997-01-01

    There are disposed an area where a conveyor is disposed for separating miscellaneous radioactive solid wastes such as metals, on area for operators which is disposed in the direction vertical to the transferring direction of the conveyor, an area for receiving the radioactive wastes and placing them on the conveyor and an area for collecting the radioactive wastes transferred by the conveyor. Since an operator can conduct handling while wearing a working cloth attached to a partition wall as he wears his ordinary cloth, the operation condition can be improved and the efficiency for the separating work can be improved. When the area for settling conveyors and the area for the operators is depressurized, cruds on the surface of the wastes are not released to the outside and the working clothes can be prevented from being involved. Since the wastes are transferred by the conveyor, the operator's moving range is reduced, poisonous materials are fallen and moved through a sliding way to an area for collecting materials to be separated. Accordingly, the materials to be removed can be accumulated easily. (N.H.)

  3. Trends in Modern Exception Handling

    Directory of Open Access Journals (Sweden)

    Marcin Kuta

    2003-01-01

    Full Text Available Exception handling is nowadays a necessary component of error proof information systems. The paper presents overview of techniques and models of exception handling, problems connected with them and potential solutions. The aspects of implementation of propagation mechanisms and exception handling, their effect on semantics and general program efficiency are also taken into account. Presented mechanisms were adopted to modern programming languages. Considering design area, formal methods and formal verification of program properties we can notice exception handling mechanisms are weakly present what makes a field for future research.

  4. United States Air Force Company Grade Officer PME and Leader Development: Establishing a Glide Path for Future Success

    National Research Council Canada - National Science Library

    Owens, Patrick

    2002-01-01

    .... This monograph addresses the role of PME at the company grade level in the development of Air Force officers in light of ongoing Army and Air Force leader development initiatives as well as recent...

  5. Transport processes associated with the initial elevated concentrations of Chernobyl radioactivity in surface air in the United States

    International Nuclear Information System (INIS)

    Larsen, R.J.; Haagenson, P.L.; Reiss, N.M.

    1989-01-01

    Elevated concentrations of radioactivity from the Chernobyl accident were encountered in the surface air over the United States along the east coast and in the north-west on 9 and 10 May 1986. The nearly simultaneous arrival of radioactive debris at widely separated locations resulted from different paths being taken by the debris released at different times during the course of the accident. Debris released during the explosion at the Chernobyl reactor was transported across the Arctic, within the lower troposphere, and zonally across Asia and the North Pacific Ocean, within the mid-troposphere. This debris descended into the planetary boundary layer along the east coast of the US. The descent was associated with a quasi-stationary cyclone located over the western North Atlantic Ocean. Debris that had a different composition of radioactivity was released from the damaged reactor during the week immediately following the initial explosion. This debris was then transported zonally across Asia and the North Pacific Ocean within the planetary boundary layer and lower troposphere and was swept into the north-western US. (author)

  6. Innovative application of air ejector as a pump for continuous air monitors

    International Nuclear Information System (INIS)

    Dhanasekaran, A.; Ajoy, K.C.; Santhanam, R.; Rajagopal, V.; Jose, M.T.

    2016-01-01

    Workplace monitoring, one of the key components of the radiation protection program is generally carried out by means of instruments installed permanently in respective areas or through portable air sampling instruments. Continuous air monitor (CAM) is one such monitor that constantly monitors the radionuclide concentration in air and triggers alarm as and when the air concentration goes above the pre-set levels. Conventional CAM system has a filter head, detector, display unit and a pump as four major parts. Pump may be either rotary vane or a vibrating diaphragm which are electrically driven using motors. Air lift pumps using ejectors are widely used where pump reliability and low maintenance are required, and where corrosive, abrasive, or radioactive fluids are handled. Since ejectors are uncomplicated alternative to vacuum pumps, an attempt was made to use the same as a pump for conventional CAMs. An ejector based sampling set up was made, tested and the results are represented in this paper

  7. METHODS FOR THE SAFE STORAGE, HANDLING, AND DISPOSAL OF PYROPHORIC LIQUIDS AND SOLIDS IN THE LABORATORY

    Energy Technology Data Exchange (ETDEWEB)

    Simmons, F.; Kuntamukkula, M.; Alnajjar, M.; Quigley, D.; Freshwater, D.; Bigger, S.

    2010-02-02

    Pyrophoric reagents represent an important class of reactants because they can participate in many different types of reactions. They are very useful in organic synthesis and in industrial applications. The Occupational Safety and Health Administration (OSHA) and the National Fire Protection Association (NFPA) define Pyrophorics as substances that will self-ignite in air at temperatures of 130 F (54.4 C) or less. However, the U.S. Department of Transportation (DOT) uses criteria different from the auto-ignition temperature criterion. The DOT defines a pyrophoric material as a liquid or solid that, even in small quantities and without an external ignition source, can ignite within five minutes after coming in contact with air when tested according to the United Nations Manual of Tests and Criteria. The Environmental Protection Agency has adopted the DOT definition. Regardless of which definition is used, oxidation of the pyrophoric reagents by oxygen or exothermic reactions with moisture in the air (resulting in the generation of a flammable gas such as hydrogen) is so rapid that ignition occurs spontaneously. Due to the inherent nature of pyrophoric substances to ignite spontaneously upon exposure to air, special precautions must be taken to ensure their safe handling and use. Pyrophoric gases (such as diborane, dichloroborane, phosphine, etc.) are typically the easiest class of pyrophoric substances to handle since the gas can be plumbed directly to the application and used remotely. Pyrophoric solids and liquids, however, require the user to physically manipulate them when transferring them from one container to another. Failure to follow proper safety precautions could result in serious injury or unintended consequences to laboratory personnel. Because of this danger, pyrophorics should be handled only by experienced personnel. Users with limited experience must be trained on how to handle pyrophoric reagents and consult with a knowledgeable staff member prior

  8. Finisher hog production in the Southeastern United States: Ancillary measurements derived from the National Air Emissions Monitoring Study (NAEMS)

    Science.gov (United States)

    Robarge, W. P.; Lee, S.; Walker, J. T.

    2010-12-01

    Measurements of emissions of gases and fine particulate matter from swine animal feeding operations (AFOs) in the southeastern US have typically been confined to relatively short periods (days to several weeks) and have generally focused on waste lagoons. Access to swine animal housing units and other ancillary information has been limited. The National Air Emissions Monitoring Study (NAEMS) provided a unique opportunity to characterize emissions from swine housing units for an extended period of time (~ 2 years), and allowed access to ancillary measurements regarding nutrient flows (feed amounts and composition), manure dynamics, animal inventories, water usage and farm management. Presented here is a summary of the observations made for a NAEMS finisher site (NC3B) selected as being representative of swine production in the southeastern US. Finisher hogs are raised in rotations (~ 140 days) with a target market weight of 123 kg/hog. Among the population during a rotation (700-800 hogs/barn) the actual growth rate varies with a series of “grade-outs” of market-weight hogs starting ~ 110 days from initial load-in. Derivation of the standing live-weight in the barns during a rotation therefore requires use of a growth model and summation over several different “populations” of hogs within a single barn. Up to 5 different feed formulations are fed during a rotation with %N content ranging from (3.4 to 2.2% N; total feed consumed 181,000 kg/barn). Across 4 complete rotations, N consumed was ~50 g N per hog/day. Of this amount, we estimate ~ 60% is excreted as fecal matter and urine. The TAN (NH3 + NH4+) content of the shallow pits is consistently higher (1880 ±390 mg TAN/L) than that found in the anaerobic lagoon (800 ±70 mg TAN/L), except immediately after recharge following pit-pull (pH of the two liquids was similar). The presence of a recalcitrant layer of sludge in the shallow pits (liquid height = 20 cm; sludge depth = 5-10 cm; TAN = 2500 mg N/L; total

  9. WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT

    Energy Technology Data Exchange (ETDEWEB)

    J. D. Bigbee

    2000-06-21

    The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status.

  10. WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT

    International Nuclear Information System (INIS)

    J. D. Bigbee

    2000-01-01

    The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status

  11. AIRS/Aqua L3 Monthly Quantization in Physical Units (AIRS+AMSU) 5 degrees x 5 degrees V006 (AIRX3QPM) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — The Atmospheric Infrared Sounder (AIRS) is a grating spectrometer (R = 1200) aboard the second Earth Observing System (EOS) polar-orbiting platform, EOS Aqua. In...

  12. Overview--Development of a geodatabase and conceptual model of the hydrogeologic units beneath Air Force Plant 4 and Naval Air Station-Joint Reserve Base Carswell Field, Fort Worth, Texas

    Science.gov (United States)

    Shah, Sachin D.

    2004-01-01

    Air Force Plant 4 (AFP4) and adjacent Naval Air Station-Joint Reserve Base Carswell Field (NAS–JRB) at Fort Worth, Tex., constitute a contractor-owned, government-operated facility that has been in operation since 1942. Contaminants from the 3,600-acre facility, primarily volatile organic compounds (VOCs) and metals, have entered the ground-water-flow system through leakage from waste-disposal sites and from manufacturing processes. Environmental data collected at AFP4 and NAS–JRB during 1993–2002 created the need for consolidation of the data into a comprehensive temporal and spatial geodatabase. The U.S. Geological Survey (USGS), in cooperation with the U.S. Air Force Aeronautical Systems Center Environmental Management Directorate, developed a comprehensive geodatabase of temporal and spatial environmental data associated with the hydrogeologic units beneath the facility. A three-dimensional conceptual model of the hydrogeologic units integrally linked to the geodatabase was designed concurrently. Three hydrogeologic units—from land surface downward, the alluvial aquifer, the GoodlandWalnut confining unit, and the Paluxy aquifer—compose the subsurface of interest at AFP4 and NAS–JRB. The alluvial aquifer consists primarily of clay and silt with sand and gravel channel deposits that might be interconnected or interfingered. The Goodland-Walnut confining unit directly underlies the alluvial aquifer and consists of limestone, marl, shale, and clay. The Paluxy aquifer is composed of dense mudstone and fine- to coarse-grained sandstone

  13. Handling of natural occurring radioactive deposits in the oil and gas industry in Norway, United Kingdom and the Netherlands; Haandtering av radioaktive avleiringer i olje- og gassproduksjon i Norge, Storbritania og Nederland

    Energy Technology Data Exchange (ETDEWEB)

    Lysebo, I.; Tufto, P

    1999-03-01

    Deposits containing naturally occurring radioactive materials is an increasing problem in oil and gas production. Laws and regulations in thisarea is under preparation, and it is a wish for harmonization with the other oil and gas producing countries in the North Sea. The report gives an overview of amounts of waste and activity levels, decontamination methods and waste handling in Norway, Great Britain and the Netherlands.

  14. Safety measuring for sodium handling

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ji Young; Jeong, K C; Kim, T J; Kim, B H; Choi, J H

    2001-09-01

    This is the report for the safety measures of sodium handling. These contents are prerequisites for the development of sodium technology and thus the workers participate in sodium handling and experiments have to know them perfectly. As an appendix, the relating parts of the laws are presented.

  15. Waste Handling Building Conceptual Study

    International Nuclear Information System (INIS)

    G.W. Rowe

    2000-01-01

    The objective of the ''Waste Handling Building Conceptual Study'' is to develop proposed design requirements for the repository Waste Handling System in sufficient detail to allow the surface facility design to proceed to the License Application effort if the proposed requirements are approved by DOE. Proposed requirements were developed to further refine waste handling facility performance characteristics and design constraints with an emphasis on supporting modular construction, minimizing fuel inventory, and optimizing facility maintainability and dry handling operations. To meet this objective, this study attempts to provide an alternative design to the Site Recommendation design that is flexible, simple, reliable, and can be constructed in phases. The design concept will be input to the ''Modular Design/Construction and Operation Options Report'', which will address the overall program objectives and direction, including options and issues associated with transportation, the subsurface facility, and Total System Life Cycle Cost. This study (herein) is limited to the Waste Handling System and associated fuel staging system

  16. The environmental handling in the Oil Wells

    International Nuclear Information System (INIS)

    Carta Petrolera

    1998-01-01

    The oil industry bears environmental impacts related to the resources, soil, air, water, fauna and the socioeconomic aspects of the environment; for this reason the search of the petroleum goes beyond what is believed, it embraces other spheres because, after discovery, it is necessary to extract it, to transport it and to treat it to put it to the service of the humanity's development and in all this long and complex process, is the environmental responsibility, a serious concern as the same discovery of the hydrocarbons. In the beginnings of the oil industry in Colombia this activity was approached without the biggest forecasts as for contamination it refers; however, the environmental laws of the world and the constant concern to preserve the environment, it took to our country to the creation of severe legislations in the matter. In Colombia today in day an environmental legislation exists in all the related with the handling of waters, air and soils inside the oil activity

  17. Shielded enclosure for handling radioactive material

    International Nuclear Information System (INIS)

    Laurent, H.; Courouble, J.M.

    1959-01-01

    Two enclosures linked by an air-lock are described: they are designed for the safe handling of 5 curies 0.3 to 0.5 MeV γ emitters, and each is composed of a semi-tight case, ventilated, clad in 80 mm steel plate, and suited for a wide variety of physics and chemistry operations. The equipment required for any given operation can be installed in the shortest possible time, access to the enclosure being via a removable front. Visual control is assured through a lead-glass screen. Each enclosure is fitted with a master-slave manipulator, Argon model 7, and plugs and air-locks are provided for the introduction of liquids and solids. (author) [fr

  18. Updated greenhouse gas and criteria air pollutant emission factors and their probability distribution functions for electricity generating units

    International Nuclear Information System (INIS)

    Cai, H.; Wang, M.; Elgowainy, A.; Han, J.

    2012-01-01

    Greenhouse gas (CO 2 , CH 4 and N 2 O, hereinafter GHG) and criteria air pollutant (CO, NO x , VOC, PM 10 , PM 2.5 and SO x , hereinafter CAP) emission factors for various types of power plants burning various fuels with different technologies are important upstream parameters for estimating life-cycle emissions associated with alternative vehicle/fuel systems in the transportation sector, especially electric vehicles. The emission factors are typically expressed in grams of GHG or CAP per kWh of electricity generated by a specific power generation technology. This document describes our approach for updating and expanding GHG and CAP emission factors in the GREET (Greenhouse Gases, Regulated Emissions, and Energy Use in Transportation) model developed at Argonne National Laboratory (see Wang 1999 and the GREET website at http://greet.es.anl.gov/main) for various power generation technologies. These GHG and CAP emissions are used to estimate the impact of electricity use by stationary and transportation applications on their fuel-cycle emissions. The electricity generation mixes and the fuel shares attributable to various combustion technologies at the national, regional and state levels are also updated in this document. The energy conversion efficiencies of electric generating units (EGUs) by fuel type and combustion technology are calculated on the basis of the lower heating values of each fuel, to be consistent with the basis used in GREET for transportation fuels. On the basis of the updated GHG and CAP emission factors and energy efficiencies of EGUs, the probability distribution functions (PDFs), which are functions that describe the relative likelihood for the emission factors and energy efficiencies as random variables to take on a given value by the integral of their own probability distributions, are updated using best-fit statistical curves to characterize the uncertainties associated with GHG and CAP emissions in life-cycle modeling with GREET.

  19. Updated greenhouse gas and criteria air pollutant emission factors and their probability distribution functions for electricity generating units

    Energy Technology Data Exchange (ETDEWEB)

    Cai, H.; Wang, M.; Elgowainy, A.; Han, J. (Energy Systems)

    2012-07-06

    Greenhouse gas (CO{sub 2}, CH{sub 4} and N{sub 2}O, hereinafter GHG) and criteria air pollutant (CO, NO{sub x}, VOC, PM{sub 10}, PM{sub 2.5} and SO{sub x}, hereinafter CAP) emission factors for various types of power plants burning various fuels with different technologies are important upstream parameters for estimating life-cycle emissions associated with alternative vehicle/fuel systems in the transportation sector, especially electric vehicles. The emission factors are typically expressed in grams of GHG or CAP per kWh of electricity generated by a specific power generation technology. This document describes our approach for updating and expanding GHG and CAP emission factors in the GREET (Greenhouse Gases, Regulated Emissions, and Energy Use in Transportation) model developed at Argonne National Laboratory (see Wang 1999 and the GREET website at http://greet.es.anl.gov/main) for various power generation technologies. These GHG and CAP emissions are used to estimate the impact of electricity use by stationary and transportation applications on their fuel-cycle emissions. The electricity generation mixes and the fuel shares attributable to various combustion technologies at the national, regional and state levels are also updated in this document. The energy conversion efficiencies of electric generating units (EGUs) by fuel type and combustion technology are calculated on the basis of the lower heating values of each fuel, to be consistent with the basis used in GREET for transportation fuels. On the basis of the updated GHG and CAP emission factors and energy efficiencies of EGUs, the probability distribution functions (PDFs), which are functions that describe the relative likelihood for the emission factors and energy efficiencies as random variables to take on a given value by the integral of their own probability distributions, are updated using best-fit statistical curves to characterize the uncertainties associated with GHG and CAP emissions in life

  20. A composite study of the MJO influence on the surface air temperature and precipitation over the Continental United States

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Shuntai [NOAA/NWS/NCEP, Camp Springs, MD (United States); Wyle, Inc., McLean, VA (United States); L' Heureux, Michelle; Weaver, Scott; Kumar, Arun [NOAA/NWS/NCEP, Camp Springs, MD (United States)

    2012-04-15

    The influence of the MJO on the continental United States (CONUS) surface air temperature (SAT) and precipitation is examined based on 30 years of daily data from 1979-2008. Composites are constructed for each of the eight phases of the Wheeler-Hendon MJO index over 12 overlapping three-month seasons. To ensure that the MJO signal is distinguished from other patterns of climate variability, several steps are taken: (a) only days classified as ''MJO events'' are used in the composites, (b) statistical significance of associated composites is assessed using a Monte Carlo procedure, and (c) intraseasonal frequencies are matched to the unfiltered data. Composites of other fields are also shown in order to examine how the SAT and precipitation anomalies are associated with large-scale circulations providing a link between the tropics and extratropics. The strongest and most significant MJO effects on SAT are found during the northern winter seasons. When enhanced convection is located over the equatorial Indian Ocean, below-average SAT tends to occur in New England and the Great Lakes region. As enhanced tropical convection shifts over the Maritime continent, above-average SAT appears in the eastern states of the US from Maine to Florida. The MJO influence on precipitation is also significant during northern winter seasons. When enhanced convection is located over the Maritime continent, more precipitation is observed in the central plains of the US. Enhanced precipitation also occurs over the west coast of the US when convective activity is stronger over the Indian Ocean. During the northern summer and fall, the MJO impact on precipitation is mainly significant at lower latitudes, over Mexico and southeastern US. (orig.)

  1. Advanced handling-systems with enhanced performance flexibility

    International Nuclear Information System (INIS)

    1986-04-01

    This report describes the results of a project related to future applications and requirements for advanced handling systems. This report consists of six chapters. Following the description of the aims the tools for setting up the requirements for the handling systems including the experience during the data acquisition process is described. Furthermore some information is given about the current state of the art of robotics and manipulators. Of paramount importance are the descriptions of applications and related concepts in the following chapters leading to specific categories of advanced handling units. The paper closes with the description of the first concepts for realization. (orig./HP) [de

  2. Experimental investigation of the effect of air velocity on a unit cooler under frosting condition: a case study

    Science.gov (United States)

    Bayrak, Ergin; Çağlayan, Akın; Konukman, Alp Er S.

    2017-10-01

    Finned tube evaporators are used in a wide range of applications such as commercial and industrial cold/freezed storage rooms with high traffic loading under frosting conditions. In this case study, an evaporator with an integrated fan was manufactured and tested under frosting conditions by only changing the air flow rate in an ambient balanced type test laboratory compared to testing in a wind tunnel with a more uniform flow distribution in order to detect the effect of air flow rate on frosting. During the test, operation was performed separately based on three different air flow rates. The parameters concerning test operation such as the changes of air temperature, air relative humidity, surface temperature, air-side pressure drop and refrigerant side capacity etc. were followed in detail for each air flow rate. At the same time, digital images were captured in front of the evaporator; thus, frost thicknesses and blockage ratios at the course of fan stall were determined by using an image-processing technique. Consequently, the test and visual results showed that the trendline of air-side pressure drop increased slowly at the first stage of test operations, then increased linearly up to a top point and then the linearity was disrupted instantly. This point speculated the beginning of defrost operation for each case. In addition, despite detecting a velocity that needs to be avoided, a test applied at minimum air velocity is superior to providing minimum capacity in terms of loss of capacity during test operations.

  3. Procedure of safe handling with cytostatic drugs

    Directory of Open Access Journals (Sweden)

    Kodžo Dragan

    2003-01-01

    Full Text Available Working group for safe handling with cytostatic drugs has been formed by the Ministry of Health, and it consists of professionals from IORS, Federal Bureau of Weights and Measures, Industrial Medicine, Institute of Hematology, Military Medical Academy, and Crown Agents. The aim of this working group is to prepare procedures for safe handling with cytostatic drugs, as well as program for educational seminar for nurses, medical technicians, and pharmaceutical technicians. The procedures will serve as a guide of good practice of oncology health care, and will refer to all actions that health care professionals carry out from the moment of drugs arrival to the pharmacy to the moment of their application. In the first segment of this procedure, general rules are given for working with cytotoxic agents, control for risky exposures, safe system of work, control of working environment, monitoring of the employees' health condition adequate protection in the working environment, protective equipment of the employees (gloves, mask, cap, eyeglasses, shoe covers, coats and chambers for vertical laminary air stream. Storing of cytostatics, procedure in case of accident, and waste handling and removal are also described in this segment. Fifty-three standard operational procedures are described in detail in the second segment. Training scheme for preparation of chemotherapy is given in the third segment - education related to various fields and practical part, which would be carried out through workshops, and at the end of the course participants would pass a test and obtain certificate. After the procedures for safe handling with cytostatics are legally regulated employer will have to provide minimum of protective equipment, special rooms for the drugs dissolving, chambers with laminar airflow, 6 hours working time, rotation of the staff working with drugs dissolving in intervals of every five years, higher efficiency, better health control. In conclusion

  4. The air quality in ventilation installations. Practical guidelines; Qualite de l'air dans les installations aerauliques. Guide pratique

    Energy Technology Data Exchange (ETDEWEB)

    Angeli, L. [France Air, 91 - Chilly Mazarin (France); Bianchina, M. [Unelvent, 93 - Le Bourget (France); Blazy, M. [Anjos, 01 - Torcieu (France); Boulanger, X. [Aldes, 21 - Chenove (France); Chiesa, M. [Atlantic (France); Duclos, M. [Groupe Titanair, 69 - Lyon (France); Hubert, D.; Kridorian, O. [Groupe Astato, Blanc Mesnil (France); Josserand, O. [Carrier (Belgium); Lancieux, C. [Camfil, 60 - Saint Martin Longueau (France); Lemaire, J.C. [Agence de l' Environnement et de la Maitrise de l' Energie, ADEME, 75 - Paris (France); Petit, Ph. [Compagnie Industrielle d' Applications Thermiques ( CIAT ), 75 - Paris (France); Ribot, B. [Electricite de France (EDF), 75 - Paris (France); Tokarek, S. [Gaz de France (GDF), 75 - Paris (France); Bernard, A.M.; Tissot, A. [Centre Technique des Industries Aerauliques et Thermiques (CETIAT), 69 - Villeurbanne (France)

    2004-07-01

    The present guide aims to provide design departments, maintenance companies and builders with practical guidelines and recommendations for the installation of ventilation and air-conditioning systems. The objective is to ensure good Indoor Air Quality (IAQ) and to safeguard the health and well-being of the occupants. The guide deals with aspects of design, dimensioning, installation and servicing, all of which play a major role in guaranteeing IAQ and duct-work hygiene. These steps are reviewed for the principal ventilation systems met in both residential and commercial premises. The first part presents the system and draws the attention of the user to specific points which require particular care in term of IAQ. The second part details recommended practice component by component, in respect of design, installation and servicing. Application of these simple guidelines during the various project stages is essential, in order to ensure a good IAQ in ventilation systems. Content: introduction; good ventilation; systems: exhaust ventilation, balanced ventilation, air handling unit, terminal ventilation units, impact of systems on indoor air quality, components: air inlet, air filter, heat recovery unit, heating or cooling coil, humidifier, mechanical fan unit, cowl and hybrid ventilation fan, mixing box, ventilation duct-work, air outlet and air terminal device; references.

  5. Sophisticated fuel handling system evolved

    International Nuclear Information System (INIS)

    Ross, D.A.

    1988-01-01

    The control systems at Sellafield fuel handling plant are described. The requirements called for built-in diagnostic features as well as the ability to handle a large sequencing application. Speed was also important; responses better than 50ms were required. The control systems are used to automate operations within each of the three main process caves - two Magnox fuel decanners and an advanced gas-cooled reactor fuel dismantler. The fuel route within the fuel handling plant is illustrated and described. ASPIC (Automated Sequence Package for Industrial Control) which was developed as a controller for the plant processes is described. (U.K.)

  6. Production management of window handles

    Directory of Open Access Journals (Sweden)

    Manuela Ingaldi

    2014-12-01

    Full Text Available In the chapter a company involved in the production of aluminum window and door handles was presented. The main customers of the company are primarily companies which produce PCV joinery and wholesalers supplying these companies. One chosen product from the research company - a single-arm pin-lift window handle - was described and its production process depicted technologically. The chapter also includes SWOT analysis conducted in the research company and the value stream of the single-arm pin-lift window handle.

  7. Overhead remote handling systems for the process facility modifications project

    International Nuclear Information System (INIS)

    Wiesener, R.W.; Grover, D.L.

    1987-01-01

    Each of the cells in the process facility modifications (PFM) project complex is provided with a variety of general purpose remote handling equipment including bridge cranes, monorail hoist, bridge-mounted electromechanical manipulator (EMM) and an overhead robot used for high efficiency particulate air (HEPA) filter changeout. This equipment supplements master-slave manipulators (MSMs) located throughout the complex to provide an overall remote handling system capability. The overhead handling equipment is used for fuel and waste material handling operations throughout the process cells. The system also provides the capability for remote replacement of all in-cell process equipment which may fail or be replaced for upgrading during the lifetime of the facility

  8. A Comparative Analysis of Patient Access Modes at Wilford Hall United States Air Force Medical Center and Selected Civilian Medical Centers

    Science.gov (United States)

    1983-12-01

    In A COMPARATIVE ANALYSIS OF PATIENT ACCESS MODES AT WILFORD HALL UNITED STATES AIR FORCE MEDICAL CENTER N AND SELECTED CIVILIAN MEDICAL CENTERS0 N...current patient access modes at WHMC and several civilian medical centers of comparable size. This project has pursued the subject of patient access in...selected civilian medical centers which are comparable to WHMC in size, specialty mix, workload, and mission, providing responsive and efficient patient

  9. Evaluation of radon occurrence in groundwater from 16 geologic units in Pennsylvania, 1986–2015, with application to potential radon exposure from groundwater and indoor air

    Science.gov (United States)

    Gross, Eliza L.

    2017-05-11

    Results from 1,041 groundwater samples collected during 1986‒2015 from 16 geologic units in Pennsylvania, associated with 25 or more groundwater samples with concentrations of radon-222, were evaluated in an effort to identify variations in radon-222 activities or concentrations and to classify potential radon-222 exposure from groundwater and indoor air. Radon-222 is hereafter referred to as “radon.” Radon concentrations in groundwater greater than or equal to the proposed U.S. Environmental Protection Agency (EPA) maximum contaminant level (MCL) for public-water supply systems of 300 picocuries per liter (pCi/L) were present in about 87 percent of the water samples, whereas concentrations greater than or equal to the proposed alternative MCL (AMCL) for public water-supply systems of 4,000 pCi/L were present in 14 percent. The highest radon concentrations were measured in groundwater from the schists, gneisses, and quartzites of the Piedmont Physiographic Province.In this study, conducted by the U.S. Geological Survey in cooperation with the Pennsylvania Department of Health and the Pennsylvania Department of Environmental Protection, groundwater samples were aggregated among 16 geologic units in Pennsylvania to identify units with high median radon concentrations in groundwater. Graphical plots and statistical tests were used to determine variations in radon concentrations in groundwater and indoor air. Median radon concentrations in groundwater samples and median radon concentrations in indoor air samples within the 16 geologic units were classified according to proposed and recommended regulatory limits to explore potential radon exposure from groundwater and indoor air. All of the geologic units, except for the Allegheny (Pa) and Glenshaw (Pcg) Formations in the Appalachian Plateaus Physiographic Province, had median radon concentrations greater than the proposed EPA MCL of 300 pCi/L, and the Peters Creek Schist (Xpc), which is in the Piedmont

  10. Impact of the 2008 Global Recession on Air Quality over the United States: Implications for Surface Ozone Levels from Changes in NOx Emissions

    Science.gov (United States)

    Tong, Daniel; Pan, Li; Chen, Weiwei; Lamsal, Lok; Lee, Pius; Tang, Youhua; Kim, Hyuncheol; Kondragunta, Shobha; Stajner, Ivanka

    2016-01-01

    Satellite and ground observations detected large variability in nitrogen oxides (NOx) during the 2008 economic recession, but the impact of the recession on air quality has not been quantified. This study combines observed NOx trends and a regional chemical transport model to quantify the impact of the recession on surface ozone (O3) levels over the continental United States. The impact is quantified by simulating O3 concentrations under two emission scenarios: business-as-usual (BAU) and recession. In the BAU case, the emission projection from the Cross-State Air Pollution Rule is used to estimate the would-be NOx emission level in 2011. In the recession case, the actual NO2 trends observed from Air Quality System ground monitors and the Ozone Monitoring Instrument on the Aura satellite are used to obtain realistic changes in NOx emissions. The model prediction with the recession effect agrees better with ground O3 observations over time and space than the prediction with the BAU emission. The results show that the recession caused a 12ppbv decrease in surface O3 concentration over the eastern United States, a slight increase (0.51ppbv) over the Rocky Mountain region, and mixed changes in the Pacific West. The gain in air quality benefits during the recession, however, could be quickly offset by the much slower emission reduction rate during the post-recession period.

  11. Compact modeling of a telecom back-up unit powered by air-cooled proton exchange membrane fuel cell

    DEFF Research Database (Denmark)

    Gao, Xin; Kær, Søren Knudsen

    2018-01-01

    Applications of proton exchange membrane fuel cells (PEMFC’s) are expanding in portable, automotive and stationary markets. One promising application is the back-up power for telecommunication applications in remote areas where usually air-cooled PMEFC’s are used. An air-cooled PEMFC system is much...

  12. Significantly reduced health burden from ambient air pollution in the United States under emission reductions from 1990 to 2010

    Science.gov (United States)

    The 2015 Global Burden of Disease (GBD) study has listed air pollution as the fourth-ranking global mortality risk factor. Many studies have estimated the global or national burden of disease attributed to air pollution. However, little effort has been focused on understanding ho...

  13. Controlling fugitive dust emissions in material handling operations

    Energy Technology Data Exchange (ETDEWEB)

    Tooker, G E

    1992-05-01

    The primary mechanism of fugitive dust generation in bulk material handling transfer operations is by dispersion of dust in turbulent air induced to flow with falling or projected material streams. This paper returns to basic theories of particle dynamics and fluid mechanics to quantify the dust generating mechanism by rational analysis. Calculations involving fluid mechanisms are made easier by the availability of the personal computer and the many math manipulating programs. Rational analysis is much more cost effective when estimating collection air volumes to control fugitive emissions; especially in enclosed material handling transfers transporting large volumes of dusty material. Example calculations, using a typical enclosed conveyor-to-conveyor transfer operation are presented to illustrate and highlight the key parameters that determine the magnitude of induced air flow that must be controlled. The methods presented in this paper for estimating collection air volumes apply only enclosed material handling transfers, exhausted to a dust collector. Since some assistance to the control of dust emissions must be given by the material handling transfer chute design, a discussion of good transfer chute design practice is presented. 4 refs., 2 figs., 2 tabs.

  14. 49 CFR 1510.11 - Handling of security service fees.

    Science.gov (United States)

    2010-10-01

    ... air carrier holds neither legal nor equitable interest in the security service fees except for the... 49 Transportation 9 2010-10-01 2010-10-01 false Handling of security service fees. 1510.11 Section 1510.11 Transportation Other Regulations Relating to Transportation (Continued) TRANSPORTATION SECURITY...

  15. Detection of oral streptococci in dental unit water lines after therapy with air turbine handpiece: biological fluid retraction more frequent than expected.

    Science.gov (United States)

    Petti, Stefano; Moroni, Catia; Messano, Giuseppe Alessio; Polimeni, Antonella

    2013-03-01

    Oral streptococci detected in water from dental unit water lines (DUWLs) are a surrogate marker of patients' biological fluid retraction during therapy. We investigated oral streptococci detection rate in DUWLs in a representative sample of private offices in real-life conditions. Samples of nondisinfected water (100 ml) were collected from the DUWL designated for the air turbine handpiece in 81 dental units, immediately after dental treatment of patients with extensive air turbine handpiece use. Water was filtered and plated on a selective medium for oral streptococci and, morphologically, typical colonies of oral streptococci were counted. The lowest detection limit was 0.01 CFU/ml. The oral streptococci detection rate was 72% (95% CI: 62-81%), with a mean level of 0.7 CFU/ml. Oral streptococci detection was not affected by handpiece age or dental treatment type, but was associated with dental unit age. Biological fluid retraction into DUWLs during patient treatment and, possibly, the risk for patient-to-patient blood- or air-borne pathogen transmission are more frequent than expected.

  16. Safe handling of radiation sources

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    This chapter discussed the subjects related to the safe handling of radiation sources: type of radiation sources, method of use: transport within premises, transport outside premises; Disposal of Gamma Sources

  17. How Retailers Handle Complaint Management

    DEFF Research Database (Denmark)

    Hansen, Torben; Wilke, Ricky; Zaichkowsky, Judy

    2009-01-01

    This article fills a gap in the literature by providing insight about the handling of complaint management (CM) across a large cross section of retailers in the grocery, furniture, electronic and auto sectors. Determinants of retailers’ CM handling are investigated and insight is gained as to the......This article fills a gap in the literature by providing insight about the handling of complaint management (CM) across a large cross section of retailers in the grocery, furniture, electronic and auto sectors. Determinants of retailers’ CM handling are investigated and insight is gained...... as to the links between CM and redress of consumers’ complaints. The results suggest that retailers who attach large negative consequences to consumer dissatisfaction are more likely than other retailers to develop a positive strategic view on customer complaining, but at the same time an increase in perceived...

  18. Ergonomic material-handling device

    Science.gov (United States)

    Barsnick, Lance E.; Zalk, David M.; Perry, Catherine M.; Biggs, Terry; Tageson, Robert E.

    2004-08-24

    A hand-held ergonomic material-handling device capable of moving heavy objects, such as large waste containers and other large objects requiring mechanical assistance. The ergonomic material-handling device can be used with neutral postures of the back, shoulders, wrists and knees, thereby reducing potential injury to the user. The device involves two key features: 1) gives the user the ability to adjust the height of the handles of the device to ergonomically fit the needs of the user's back, wrists and shoulders; and 2) has a rounded handlebar shape, as well as the size and configuration of the handles which keep the user's wrists in a neutral posture during manipulation of the device.

  19. The technique on handling radiation

    International Nuclear Information System (INIS)

    1997-11-01

    This book describes measurement of radiation and handling radiation. The first part deals with measurement of radiation. The contents of this part are characteristic on measurement technique of radiation, radiation detector, measurement of energy spectrum, measurement of radioactivity, measurement for a level of radiation and county's statistics on radiation. The second parts explains handling radiation with treating of sealed radioisotope, treating unsealed source and radiation shield.

  20. Civilsamfundets ABC: H for Handling

    DEFF Research Database (Denmark)

    Lund, Anker Brink; Meyer, Gitte

    2015-01-01

    Hvad er civilsamfundet? Anker Brink Lund og Gitte Meyer fra CBS Center for Civil Society Studies gennemgår civilsamfundet bogstav for bogstav. Vi er nået til H for Handling.......Hvad er civilsamfundet? Anker Brink Lund og Gitte Meyer fra CBS Center for Civil Society Studies gennemgår civilsamfundet bogstav for bogstav. Vi er nået til H for Handling....

  1. Petroleum Refineries (Catalytic Cracking, Catalytic Reforming and Sulfur Recovery Units): National Emission Standards for Hazardous Air Pollutants (NESHAP)

    Science.gov (United States)

    learn more about the NESHAP for catalytic cracking and reforming units, as well as sulfur recovery units in petroleum refineries by reading the rule history, rule summary, background information documents, and compliance information

  2. Uranium hexafluoride: Handling procedures and container descriptions

    International Nuclear Information System (INIS)

    1987-09-01

    The US Department of Energy (DOE) guidelines for packaging, measuring, and transferring uranium hexafluoride (UF 6 ) have been undergoing continual review and revision for several years to keep them in phase with developing agreements for the supply of enriched uranium. Initially, K-1323 ''A Brief Guide to UF 6 Handling,'' was issued in 1957. This was superceded by ORO-651, first issued in 1966, and reissued in 1967 to make editorial changes and to provide minor revisions in procedural information. In 1968 and 1972, Revisions 2 and 3, respectively, were issued as part of the continuing effort to present updated information. Revision 4 issued in 1977 included revisions to UF 6 cylinders, valves, and methods to use. Revision 5 adds information dealing with pigtails, overfilled cylinders, definitions and handling precautions, and cylinder heel reduction procedures. Weighing standards previously presented in ORO-671, Vol. 1 (Procedures for Handling and Analysis of UF 6 ) have also been included. This revision, therefore, supercedes ORO-671-1 as well as all prior issues of this report. These guidelines will normally apply in all transactions involving receipt or shipment of UF 6 by DOE, unless stipulated otherwise by contracts or agreements with DOE or by notices published in the Federal Register. Any questions or requests for additional information on the subject matter covered herein should be directed to the United States Department of Energy, P.O. Box E, Oak Ridge, Tennessee 37831, Attention: Director, Uranium Enrichment Operations Division. 33 figs., 12 tabs

  3. Independent Auditors Report on the Air Force General Fund FY 2015 and FY 2014 Basic Financial Statements for United States Air Force Agency Financial Report 2015

    Science.gov (United States)

    2015-11-09

    for leadership, and the motivation to serve as Air Force career officers. Each cadet graduates with a Bachelor of Science degree and a commission...security requirement. RDT&E Major Programs ($ in millions) FY 15 Expenditure Science and Technology $2,282 Long Range Strike-Bomber $914 KC-46 $786...6,183,517) Net Cost before Losses/(Gains) from Actuarial Assumption Changes 156,816,790 154,945,254 for Military Retirement Benefits Net Program

  4. Independent Auditors Report on the Air Force Working Capital Fund FY 2015 and FY 2014 Basic Financial Statements for United States Air Force Agency Financial Report 2015

    Science.gov (United States)

    2015-11-09

    and character essential for leadership, and the motivation to serve as Air Force career officers. Each cadet graduates with a Bachelor of Science ...and specific national security requirement. RDT&E Major Programs ($ in millions) FY 15 Expenditure Science and Technology $2,282 Long Range Strike...1,243,894 (Less: Earned Revenue) Net Cost before Losses/(Gains) from Actuarial Assumption Changes for Military Retirement Benefits Net Program Costs

  5. United States Air Force Research on Airfield Pavement Repairs Using Precast Portland Cement Concrete (PCC) Slabs (BRIEFING SLIDES)

    National Research Council Canada - National Science Library

    Saeed, Athar

    2008-01-01

    ...) slab repairs using precast PCC slab panels. AFRL is leading the technology development by critically reviewing the research conducted to date in this arena by the Air Force and the highway and civil aviation agencies and adopting...

  6. Quantifying the co-impacts of energy sector decarbonisation on outdoor air pollution in the United Kingdom

    International Nuclear Information System (INIS)

    Lott, Melissa C.; Pye, Steve; Dodds, Paul E.

    2017-01-01

    The energy sector is a major contributor to greenhouse gas (GHG) emissions and other types of air pollution that negatively impact human health and the environment. Policy targets to achieve decarbonisation goals for national energy systems will therefore impact levels of air pollution. Advantages can be gained from considering these co-impacts when analysing technology transition scenarios in order to avoid tension between climate change and air quality policies. We incorporated non-GHG air pollution into a bottom-up, technoeconomic energy systems model that is at the core of UK decarbonisation policy development. We then used this model to assess the co-impacts of decarbonisation on other types of air pollution and evaluated the extent to which transition pathways would be altered if these other pollutants were considered. In a scenario where the UK meets its existing decarbonisation targets to 2050, including the costs of non-GHG air pollution led to a 40% and 45% decrease in PM_1_0 and PM_2_._5 pollution (respectively) between 2010 and 2050 due to changes in technology choice in residential heating. Conversely, limited change in the pollution profile for transportation were observed, suggesting that other policy strategies will be necessary to reduce pollution from transport. - Highlights: • Strategies to decarbonise energy systems should consider other air pollutants. • Energy systems models can show decarbonisation pathway co-impacts on PM, NO_x and SO_x. • Considering non-GHG pollution eliminates carbon & air quality policy tensions. • Transport particulate pollution challenges will only be addressed by modal shifting.

  7. The potential impacts of climate variability and change on air pollution-related health effects in the United States.

    OpenAIRE

    Bernard, S M; Samet, J M; Grambsch, A; Ebi, K L; Romieu, I

    2001-01-01

    Climate change may affect exposures to air pollutants by affecting weather, anthropogenic emissions, and biogenic emissions and by changing the distribution and types of airborne allergens. Local temperature, precipitation, clouds, atmospheric water vapor, wind speed, and wind direction influence atmospheric chemical processes, and interactions occur between local and global-scale environments. If the climate becomes warmer and more variable, air quality is likely to be affected. However, the...

  8. National Commission on the Structure of the Air Force: Report to the President and Congress of the United States

    Science.gov (United States)

    2014-01-30

    August 20, 2013, with public hearing in Oklahoma City Alpena CRTC, Mich., September 13, 2013 Selfridge ANGB, Mich., September 14, 2013, with public...Colonel Bryan Teff (ANG), Commander, Alpena Combat Readiness Training Center, Michigan Colonel Sean Southworth (ANG), Commander, 217th Air Operations...Group, W.K. Kellogg ANGB, Michigan Lieutenant Colonel Matt Trumble (ANG), Director of Operations, Grayling Air Gunnery Range, Alpena Combat Readiness

  9. Assessment and remediation of odor emissions from a complex industrial facility (Ambient air odor regulations in Canada and the United States)

    International Nuclear Information System (INIS)

    Boose, T.; Reusing, G.

    2002-01-01

    This paper describes the findings of a review and presents examples of ambient air odor regulations in Canada and the United States. State and provincial odor regulations were reviewed and other metropolitan cities or counties (regions) that have separate odor regulations were also included. The key topics addressed in this paper include an assessment of the methods used for odor regulation and the methods used to evaluate the odor impact to determine compliance with the regulation. Three types of ambient air odor regulations were identified: 1. 28 States, Provinces and regions (jurisdictions) have specific odor regulations. These regulations generally define what constitutes an odor impact and typically provide requirements for remedial measures; 2. 25 jurisdictions regulate odors by a general prohibition regulation. These regulations define odor in ambient air as a condition of air pollution, nuisance or objectionable odor that would typically prevent persons from the enjoyment of life and property; and 3. 13 jurisdictions do not have specific or general prohibition regulations regarding odors. For the jurisdictions that have specific or general prohibition odor regulations, there are a number of different techniques used to define what constitutes an odor impact. Odor impacts are typically defined in a regulation by one (or more) of the following techniques: dilution to threshold, or odor unit limit; determination of odor emission rates; odor concentration limits for selected chemicals (ppm); comparison with the n-butanol intensity scale (1 to 8); and investigation by an agency investigator. Compliance with odor regulations is typically determined using one (or more) of the following field methods: odor stack testing and dispersion modelling; odor panel analysis of stack or ambient air samples; chemical monitoring (ppm); odor school certified / agency investigator; and scentometer. (author)

  10. A study of the reverse cycle defrosting performance on a multi-circuit outdoor coil unit in an air source heat pump – Part I: Experiments

    International Nuclear Information System (INIS)

    Qu, Minglu; Xia, Liang; Deng, Shiming; Jiang, Yiqiang

    2012-01-01

    Highlights: ► We experimental study the defrosting performance on a multi-circuit outdoor coil unit in an ASHP unit. ► We find that defrosting is quicker on the airside of upper circuits than that on the lower circuits. ► We discuss the effects of downwards flowing of the melted frost along the outdoor coil surface on defrosting performance. -- Abstract: When an air source heat pump (ASHP) unit operates in heating mode, frost can be accumulated on the surface of its finned outdoor coil which normally has multiple parallel circuits on its refrigerant side for minimized refrigerant pressure loss and enhanced heat transfer efficiency. On its airside, however, there is usually no segmentation corresponding to the number of refrigerant circuit. Frosting deteriorates the operation and energy efficiency of the ASHP unit and periodic defrosting becomes necessary. Currently the most widely used standard defrosting method for ASHPs is reverse cycle defrost. This paper, the first part of a two-part series, reports on the experimental part of a study of the reverse cycle defrosting performance on a multi-circuit outdoor coil unit in an experimental 6.5 kW heating capacity residential ASHP unit. Firstly the experimental ASHP unit is described and experimental procedures detailed. Secondly, the experimental results are reported. This is followed by the discussion on the effects of downwards flowing of the melted frost along a multi-circuit outdoor coil surface on defrosting performance. Finally, the evaluation of the defrosting efficiency for the experimental ASHP unit is provided. In the second part of the series, a modeling analysis on the effects of downwards flowing of the melted frost along the multi-circuit outdoor coil surface on defrosting performance of the experimental ASHP unit will be presented.

  11. Asthma, guides for diagnostic and handling

    International Nuclear Information System (INIS)

    Salgado, Carlos E; Caballero A, Andres S; Garcia G, Elizabeth

    1999-01-01

    The paper defines the asthma, includes topics as diagnostic, handling of the asthma, special situations as asthma and pregnancy, handling of the asthmatic patient's perioperatory and occupational asthma

  12. SRV-automatic handling device

    International Nuclear Information System (INIS)

    Yamada, Koji

    1987-01-01

    Automatic handling device for the steam relief valves (SRV's) is developed in order to achieve a decrease in exposure of workers, increase in availability factor, improvement in reliability, improvement in safety of operation, and labor saving. A survey is made during a periodical inspection to examine the actual SVR handling operation. An SRV automatic handling device consists of four components: conveyor, armed conveyor, lifting machine, and control/monitoring system. The conveyor is so designed that the existing I-rail installed in the containment vessel can be used without any modification. This is employed for conveying an SRV along the rail. The armed conveyor, designed for a box rail, is used for an SRV installed away from the rail. By using the lifting machine, an SRV installed away from the I-rail is brought to a spot just below the rail so that the SRV can be transferred by the conveyor. The control/monitoring system consists of a control computer, operation panel, TV monitor and annunciator. The SRV handling device is operated by remote control from a control room. A trial equipment is constructed and performance/function testing is carried out using actual SRV's. As a result, is it shown that the SRV handling device requires only two operators to serve satisfactorily. The required time for removal and replacement of one SRV is about 10 minutes. (Nogami, K.)

  13. Recent fuel handling experience in Canada

    International Nuclear Information System (INIS)

    Welch, A.C.

    1991-01-01

    For many years, good operation of the fuel handling system at Ontario Hydro's nuclear stations has been taken for granted with the unavailability of the station arising from fuel handling system-related problems usually contributing less than one percent of the total unavailability of the stations. While the situation at the newer Hydro stations continues generally to be good (with the specific exception of some units at Pickering B) some specific and some general problems have caused significant loss of availability at the older plants (Pickering A and Bruce A). Generally the experience at the 600 MWe units in Canada has also continued to be good with Point Lepreau leading the world in availability. As a result of working to correct identified deficiencies, there were some changes for the better as some items of equipment that were a chronic source of trouble were replaced with improved components. In addition, the fuel handling system has been used three times as a delivery system for large-scale non destructive examination of the pressure tubes, twice at Bruce and once at Pickering and performing these inspections this way has saved many days of reactor downtime. Under COG there are several programs to develop improved versions of some of the main assemblies of the fuelling machine head. This paper will generally cover the events relating to Pickering in more detail but will describe the problems with the Bruce Fuelling Machine Bridges since the 600 MW 1P stations have a bridge drive arrangement that is somewhat similar to Bruce

  14. The potential impacts of climate variability and change on air pollution-related health effects in the United States.

    Science.gov (United States)

    Bernard, S M; Samet, J M; Grambsch, A; Ebi, K L; Romieu, I

    2001-05-01

    Climate change may affect exposures to air pollutants by affecting weather, anthropogenic emissions, and biogenic emissions and by changing the distribution and types of airborne allergens. Local temperature, precipitation, clouds, atmospheric water vapor, wind speed, and wind direction influence atmospheric chemical processes, and interactions occur between local and global-scale environments. If the climate becomes warmer and more variable, air quality is likely to be affected. However, the specific types of change (i.e., local, regional, or global), the direction of change in a particular location (i.e., positive or negative), and the magnitude of change in air quality that may be attributable to climate change are a matter of speculation, based on extrapolating present understanding to future scenarios. There is already extensive evidence on the health effects of air pollution. Ground-level ozone can exacerbate chronic respiratory diseases and cause short-term reductions in lung function. Exposure to particulate matter can aggravate chronic respiratory and cardiovascular diseases, alter host defenses, damage lung tissue, lead to premature death, and possibly contribute to cancer. Health effects of exposures to carbon monoxide, sulfur dioxide, and nitrogen dioxide can include reduced work capacity, aggravation of existing cardiovascular diseases, effects on pulmonary function, respiratory illnesses, lung irritation, and alterations in the lung's defense systems. Adaptations to climate change should include ensuring responsiveness of air quality protection programs to changing pollution levels. Research needs include basic atmospheric science work on the association between weather and air pollutants; improving air pollution models and their linkage with climate change scenarios; and closing gaps in the understanding of exposure patterns and health effects.

  15. Indirect Encoding in Neuroevolutionary Ship Handling

    Directory of Open Access Journals (Sweden)

    Miroslaw Lacki

    2018-03-01

    Full Text Available In this paper the author compares the efficiency of two encoding schemes for artificial intelligence methods used in the neuroevolutionary ship maneuvering system. This may be also be seen as the ship handling system that simulates a learning process of a group of artificial helmsmen - autonomous control units, created with an artificial neural network. The helmsman observes input signals derived form an enfironment and calculates the values of required parameters of the vessel maneuvering in confined waters. In neuroevolution such units are treated as individuals in population of artificial neural networks, which through environmental sensing and evolutionary algorithms learn to perform given task efficiently. The main task of this project is to evolve a population of helmsmen with indirect encoding and compare results of simulation with direct encoding method.

  16. Effect of land cover on atmospheric processes and air quality over the continental United States – a NASA Unified WRF (NU-WRF model study

    Directory of Open Access Journals (Sweden)

    Z. Tao

    2013-07-01

    Full Text Available The land surface plays a crucial role in regulating water and energy fluxes at the land–atmosphere (L–A interface and controls many processes and feedbacks in the climate system. Land cover and vegetation type remains one key determinant of soil moisture content that impacts air temperature, planetary boundary layer (PBL evolution, and precipitation through soil-moisture–evapotranspiration coupling. In turn, it will affect atmospheric chemistry and air quality. This paper presents the results of a modeling study of the effect of land cover on some key L–A processes with a focus on air quality. The newly developed NASA Unified Weather Research and Forecast (NU-WRF modeling system couples NASA's Land Information System (LIS with the community WRF model and allows users to explore the L–A processes and feedbacks. Three commonly used satellite-derived land cover datasets – i.e., from the US Geological Survey (USGS and University of Maryland (UMD, which are based on the Advanced Very High Resolution Radiometer (AVHRR, and from the Moderate Resolution Imaging Spectroradiometer (MODIS – bear large differences in agriculture, forest, grassland, and urban spatial distributions in the continental United States, and thus provide an excellent case to investigate how land cover change would impact atmospheric processes and air quality. The weeklong simulations demonstrate the noticeable differences in soil moisture/temperature, latent/sensible heat flux, PBL height, wind, NO2/ozone, and PM2.5 air quality. These discrepancies can be traced to associate with the land cover properties, e.g., stomatal resistance, albedo and emissivity, and roughness characteristics. It also implies that the rapid urban growth may have complex air quality implications with reductions in peak ozone but more frequent high ozone events.

  17. Size Distribution and Rate of Dust Generated During Grain Elevator Handling

    Science.gov (United States)

    Dust generated during grain handling is an air pollutant that produces safety and health hazards. This study was conducted to characterize the particle size distribution (PSD) of dust generated during handling of wheat and shelled corn in the research elevator of the USDA Grain Marketing and Product...

  18. Air Land Sea Bulletin

    Science.gov (United States)

    2014-11-01

    Unidentified Royal Air Force Regiment forward air controllers from the Air Land Integration Cell , Based at Royal Air Force Honington, Suffolk (United...heavy as an actual weapon.4 Ideally, this practice imbued a soldier with more energy and stamina during real combat, given the feel of the genuine but...through tactical forces, to individual training. Unidentified Royal Air Force Regiment forward air controllers from the Air Land Integration Cell , Based

  19. Handling of waste in ports

    International Nuclear Information System (INIS)

    Olson, P.H.

    1994-01-01

    The regulations governing the handling of port-generated waste are often national and/or local legislation, whereas the handling of ship-generated waste is governed by the MARPOL Convention in most parts of the world. The handling of waste consists of two main phases -collection and treatment. Waste has to be collected in every port and on board every ship, whereas generally only some wastes are treated and to a certain degree in ports and on board ships. This paper considers the different kinds of waste generated in both ports and on board ships, where and how it is generated, how it could be collected and treated. The two sources are treated together to show how some ship-generated waste may be treated in port installations primarily constructed for the treatment of the port-generated waste, making integrated use of the available treatment facilities. (author)

  20. 'Relax and take a deep breath': print media coverage of asthma and air pollution in the United States.

    Science.gov (United States)

    Mayer, Brian

    2012-09-01

    The media are an important social actor in the construction of the public's understanding of the complex relationships between the environment and their health. This paper explores the print media's coverage of the relationship between asthma and air pollution, focusing on the portrayal of causal certainty between exposure to various forms of air pollution and the etiology and exacerbation of the disease. By examining twenty years of newspaper articles from the New York Timeş Los Angeles Times, and the Washington Post, this paper presents findings on trends across time, within papers, and across key themes. Although the print media's coverage of asthma and its environmental correlates has increased over time, this paper finds relatively little coherence in whether asthma is portrayed as directly caused by air pollution or triggered by exposures. In terms of coverage, outdoor sources of air pollution are covered more frequently - but with less certainty in the discussion of specific relationships. This lack of coherence and specificity in the portrayal of asthma as an environmental disease may weaken regulators' ability to act in passing air pollution reforms by lowering the public's interest and concern. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Air clearing pressure oscillation produced in a quenching tank by a prototype unit cell sparger of the APR1400

    International Nuclear Information System (INIS)

    Cho, Seok; Song, Chul-Hwa; Park, Choon-Kyong; Kim, Hwan-Yeol; Baek, Won-Pil

    2008-01-01

    KAERI has performed a series of experiments to investigate the performance of a prototype sparger for the APR1400 in view of a dynamic load oscillation with a variation of the test conditions such as a discharged air mass, a submergence of the sparger, the valve opening time, and the pool temperature during an air clearing phase. The air mass and pool temperature are in the range of 0.8-1.5 kg and 20-90 o C, respectively. The valve opening time can be adjusted within the range of 0.6-1.8 s. The maximum positive pressure amplitude, which is observed at the bottom of the quenching tank, is increased with the maximum header pressure of the sparger. The valve opening time has a considerable effect on the maximum amplitude. As the opening time decreases, the maximum amplitude at the tank wall is increased. Air mass and pool temperature, however, have a weak effect on the maximum amplitude. Oscillation frequency is decreased with an increase of the air mass in the range of 2.5-4.5 Hz

  2. Development of a geodatabase and conceptual model of the hydrogeologic units beneath air force plant 4 and Naval Air Station-Joint Reserve Base Carswell Field, Fort Worth, Texas

    Science.gov (United States)

    Shah, Sachin D.

    2004-01-01

    Air Force Plant 4 and adjacent Naval Air Station-Joint Reserve Base Carswell Field at Fort Worth, Texas, constitute a government-owned, contractor-operated facility that has been in operation since 1942. Contaminants from AFP4, primarily volatile organic compounds and metals, have entered the ground-water-flow system through leakage from waste-disposal sites and from manufacturing processes. The U.S. Geological Survey developed a comprehensive geodatabase of temporal and spatial environmental information associated with the hydrogeologic units (alluvial aquifer, Goodland-Walnut confining unit, and Paluxy aquifer) beneath the facility and a three-dimensional conceptual model of the hydrogeologic units integrally linked to the geodatabase. The geodatabase design uses a thematic layer approach to create layers of feature data using a geographic information system. The various features are separated into relational tables in the geodatabase on the basis of how they interact and correspond to one another. Using the geodatabase, geographic data at the site are manipulated to produce maps, allow interactive queries, and perform spatial analyses. The conceptual model for the study area comprises computer-generated, three-dimensional block diagrams of the hydrogeologic units. The conceptual model provides a platform for visualization of hydrogeologic-unit sections and surfaces and for subsurface environmental analyses. The conceptual model is based on three structural surfaces and two thickness configurations of the study area. The three structural surfaces depict the altitudes of the tops of the three hydrogeologic units. The two thickness configurations are those of the alluvial aquifer and the Goodland-Walnut confining unit. The surface of the alluvial aquifer was created using a U.S. Geological Survey 10-meter digital elevation model. The 2,130 point altitudes of the top of the Goodland-Walnut unit were compiled from lithologic logs from existing wells, available soil

  3. A parametric study on a humidification–dehumidification (HDH) desalination unit powered by solar air and water heaters

    International Nuclear Information System (INIS)

    Yıldırım, Cihan; Solmuş, İsmail

    2014-01-01

    Highlights: • A time dependent humidification–dehumidification desalination process is investigated. • Fourth-order Runge–Kutta method is used to simulate the problem. • Daily and annual performance are examined. • Various operational parameters are investigated. - Abstract: The performance of a solar powered humidification–dehumidification desalination system is theoretically investigated for various operating and design parameters of the system under climatological conditions of Antalya, Turkey. The primary components of the system are a flat plate solar water heater, a flat plate double pass solar air heater, a humidifier, a dehumidifier and a storage tank. The mathematical model of the system is developed and governing conservation equations are numerically solved by using the Fourth order Runge–Kutta method. Daily and annual yields are calculated for different configurations of the system such as only water heating, only air heating and water–air heating

  4. 77 FR 60481 - Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units of Post-Accident...

    Science.gov (United States)

    2012-10-03

    ... filtration and iodine adsorption units of ESF atmosphere cleanup systems in light-water-cooled nuclear power... Filtration and Adsorption Units of Post-Accident Engineered-Safety-Feature Atmosphere Cleanup Systems in Light-Water-Cooled Nuclear Power Plants AGENCY: Nuclear Regulatory Commission. ACTION: Regulatory guide...

  5. Source evaluation report phase 2 investigation: Limited field investigation. Final report: United States Air Force Environmental Restoration Program, Eielson Air Force Base, Alaska

    Energy Technology Data Exchange (ETDEWEB)

    1994-10-01

    This report describes the limited field investigation work done to address issues and answer unresolved questions regarding a collection of potential contaminant sources at Eielson Air Force Base (AFB), near Fairbanks, Alaska. These sources were listed in the Eielson AFB Federal Facility Agreement supporting the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) cleanup of the base. The limited field investigation began in 1993 to resolve all remaining technical issues and provide the data and analysis required to evaluate the environmental hazard associated with these sites. The objective of the limited field investigation was to allow the remedial project managers to sort each site into one of three categories: requiring remedial investigation/feasibility study, requiring interim removal action, or requiring no further remedial action.

  6. Addressing Global Warming, Air Pollution, Energy Security, and Jobs with Roadmaps for Changing the All-Purpose Energy Infrastructure of the 50 United States

    Science.gov (United States)

    Jacobson, M. Z.

    2014-12-01

    Global warming, air pollution, and energy insecurity are three of the most significant problems facing the world today. This talk discusses the development of technical and economic plans to convert the energy infrastructure of each of the 50 United States to those powered by 100% wind, water, and sunlight (WWS) for all purposes, namely electricity, transportation, industry, and heating/cooling, after energy efficiency measures have been accounted for. The plans call for all new energy to be WWS by 2020, ~80% conversion of existing energy by 2030, and 100% by 2050 through aggressive policy measures and natural transition. Resource availability, footprint and spacing areas required, jobs created versus lost, energy costs, avoided costs from air pollution mortality and morbidity and climate damage, and methods of ensuring reliability of the grid are discussed. Please see http://web.stanford.edu/group/efmh/jacobson/Articles/I/WWS-50-USState-plans.html

  7. Experiences with decontaminating tritium-handling apparatus

    International Nuclear Information System (INIS)

    Maienschein, J.L.; Garcia, F.; Garza, R.G.; Kanna, R.L.; Mayhugh, S.R.; Taylor, D.T.

    1992-01-01

    Tritium-handling apparatus has been decontaminated as part of the downsizing of the LLNL Tritium Facility. Two stainless-steel glove boxes that had been used to process lithium deuteride-tritide (LiDT) slat were decontaminated using the Portable Cleanup System so that they could be flushed with room air through the facility ventilation system. In this paper the details on the decontamination operation are provided. A series of metal (palladium and vanadium) hydride storage beds have been drained of tritium and flushed with deuterium, in order to remove as much tritium as possible. The bed draining and flushing procedure is described, and a calculational method is presented which allows estimation of the tritium remaining in a bed after it has been drained and flushed. Data on specific bed draining and flushing are given

  8. Safety in handling helium and nitrogen

    International Nuclear Information System (INIS)

    Schmauch, G.; Lansing, L.; Santay, T.; Nahmias, D.

    1991-01-01

    Based upon the authors' industrial experience and practices, they have provided an overview of safety in storage, handling, and transfer of both laboratory and bulk quantities of gaseous and liquid forms of nitrogen and helium. They have addressed the properties and characteristics of both the gaseous and liquid fluids, typical storage and transport containers, transfer techniques, and the associated hazards which include low temperatures, high pressures, and asphyxiation. Methods and procedures to control and eliminate these hazards are described, as well as risk remediation through safety awareness training, personal protective equipment, area ventilation, and atmosphere monitoring. They have included as an example a recent process hazards analysis performed by Air Products on the asphyxiation hazard associated with the use of liquid helium in MRI magnet systems

  9. Royal Danish Air Force. Air Operations Doctrine

    DEFF Research Database (Denmark)

    Nørby, Søren

    This brief examines the development of the first Danish Air Force Air Operations Doctrine, which was officially commissioned in October 1997 and remained in effect until 2010. The development of a Danish air power doctrine was heavily influenced by the work of Colonel John Warden (USAF), both...... through his book ”The Air Campaign” and his subsequent planning of the air campaign against Iraq in 1990-1991. Warden’s ideas came to Denmark and the Danish Air Force by way of Danish Air Force students attending the United States Air Force Air University in Alabama, USA. Back in Denmark, graduates from...... the Air University inspired a small number of passionate airmen, who then wrote the Danish Air Operations Doctrine. The process was supported by the Air Force Tactical Command, which found that the work dovetailed perfectly with the transformation process that the Danish Air Force was in the midst...

  10. The nexus between energy systems and public health: an investigation into the co-impacts of energy sector technology transitions on outdoor air pollution and public health in The United Kingdom and Greater London

    OpenAIRE

    Lott, Melissa Christenberry

    2017-01-01

    There is significant value to be gained from insights on the trade-offs and synergies between proposed air quality and climate interventions. But, the models used in support of decarbonisation and air quality policies have not holistically considered these co-impacts. This thesis documents the use of an energy systems model to quantify the co-impacts of decarbonisation pathways on air pollution and vice versa in the United Kingdom. This manuscript further documents the soft-linking of this mo...

  11. The Impact of Total Liberalization of Domestic Air Transport on the Social Welfare and on the Dynamic of Competition: Comparison Between the United States and the European Union

    Science.gov (United States)

    Zbidi, Karim

    2003-01-01

    Since the lst of April 1997 date of the implementation of the third package of the liberalization, air transport, within the european Union has become totally liberalized. In the United States the deregulation of domestic air traffic was earlier and faster since it took place in October 1978 after the adoption of the only act of deregulation. This paper, in its first part, deals with the liberalization of the industry of air traffic in the european union. After a comparison with US system based on market demand, fare policy and network restrictions, we present our descriptive results coming from treatments on the OAG data. These results present several aspects such as the evolution of the competitive structure of the intra-european routes, the level of airport dominance and the growth of hub structure. The second part of the paper presents models of entry in the airline industry. As profitability" of route flown explains correctly decisions taken by airlines to serve or not a route, the paper focuses on the specification and the estimation of the determinants of city, pair profitability in the european union. Treatments done on the OAG data show a rapid development of leasing space agreement (partial and total) and code sharing practices between 1995 and 2000 in Europe that's why we differentiate first between the two type of competitive strategy of entry(direct entry and leasing space agreement) and second between the competitive strategy of entry and the alliance strategy of code sharing. So the estimation of model will be able to answer the question if the european air transport market is contestable and in case not to see if the decision of entry is more directed by the level of airport dominance (as in the domestic United States market)or essentially by the competitive structure of the routes. We try to explain the nature of entry(directleasing or code sharing) by the different levels of these two determinants.

  12. Assessment and economic valuation of air pollution impacts on human health over Europe and the United States as calculated by a multi-model ensemble in the framework of AQMEII3

    Science.gov (United States)

    The impact of air pollution on human health and the associated external costs in Europe and the United States (US) for the year 2010 are modeled by a multi-model ensemble of regional models in the frame of the third phase of the Air Quality Modelling Evaluation International Init...

  13. Differential Exposure to Hazardous Air Pollution in the United States: A Multilevel Analysis of Urbanization and Neighborhood Socioeconomic Deprivation

    Directory of Open Access Journals (Sweden)

    Frank C. Curriero

    2012-06-01

    Full Text Available Population exposure to multiple chemicals in air presents significant challenges for environmental public health. Air quality regulations distinguish criteria air pollutants (CAPs (e.g., ozone, PM2.5 from hazardous air pollutants (HAPs—187 chemicals which include carcinogens and others that are associated with respiratory, cardiovascular, neurological and numerous other non-cancer health effects. Evidence of the public’s cumulative exposure and the health effects of HAPs are quite limited. A multilevel model is used to assess differential exposure to HAP respiratory, neurological, and cancer hazards (2005 related to the Townsend Index of Socioeconomic Deprivation (TSI, after adjustment for regional population size and economic activity, and local population density. We found significant positive associations between tract TSI and respiratory and cancer HAP exposure hazards, and smaller effects for neurological HAPs. Tracts in the top quintile of TSI have between 38%–60% higher HAP exposure than the bottom quintile; increasing population size from the bottom quintile to the top quintile modifies HAP exposure hazard related to TSI, increasing cancer HAP exposure hazard by 6% to 20% and increasing respiratory HAP exposure hazard by 12% to 27%. This study demonstrates the value of social epidemiological methods for analyzing differential exposure and advancing cumulative risk assessment.

  14. Differential exposure to hazardous air pollution in the United States: a multilevel analysis of urbanization and neighborhood socioeconomic deprivation.

    Science.gov (United States)

    Young, Gary S; Fox, Mary A; Trush, Michael; Kanarek, Norma; Glass, Thomas A; Curriero, Frank C

    2012-06-01

    Population exposure to multiple chemicals in air presents significant challenges for environmental public health. Air quality regulations distinguish criteria air pollutants (CAPs) (e.g., ozone, PM2.5) from hazardous air pollutants (HAPs)-187 chemicals which include carcinogens and others that are associated with respiratory, cardiovascular, neurological and numerous other non-cancer health effects. Evidence of the public's cumulative exposure and the health effects of HAPs are quite limited. A multilevel model is used to assess differential exposure to HAP respiratory, neurological, and cancer hazards (2005) related to the Townsend Index of Socioeconomic Deprivation (TSI), after adjustment for regional population size and economic activity, and local population density. We found significant positive associations between tract TSI and respiratory and cancer HAP exposure hazards, and smaller effects for neurological HAPs. Tracts in the top quintile of TSI have between 38%-60% higher HAP exposure than the bottom quintile; increasing population size from the bottom quintile to the top quintile modifies HAP exposure hazard related to TSI, increasing cancer HAP exposure hazard by 6% to 20% and increasing respiratory HAP exposure hazard by 12% to 27%. This study demonstrates the value of social epidemiological methods for analyzing differential exposure and advancing cumulative risk assessment.

  15. 77 FR 66595 - U.S. Air Force Broadcast of Consent Order, and Determination of Interest Level for a United...

    Science.gov (United States)

    2012-11-06

    ... the Consent Order, and the role of the Compliance Officer to oversee the Respondents' compliance with... solicitation issuance. The Deputy Under Secretary of the Air Force (Space), as the Compliance Officer under the... the Department of Defense appoint a Compliance Officer to oversee compliance with the Consent Order by...

  16. An Analysis of the Efficiency of Sourcing Knowledge-based Services in the United States Air Force

    Science.gov (United States)

    2013-06-01

    by Contract Type ..... 71 Table 11. Taxonomy for Deliverables (After Lovelock and Wirtz, 2007) ............. 74 Table 12. Breakdown of Selected Air...consumption (Fitzsimmons & Fitzsimmons, 2008). Lovelock and Wirtz (2007) defined services as 12 economic activities offered by one party to another...price, they often make it difficult for suppliers to understand the market. Lovelock and Wirtz (2007) discussed eight characteristic that suppliers

  17. Software for handling MFME1

    International Nuclear Information System (INIS)

    Van der Merwe, W.G.

    1984-01-01

    The report deals with SEMFIP, a computer code for determining magnetic field measurements. The program is written in FORTRAN and ASSEMBLER. The preparations for establishing SEMFIP, the actual measurements, data handling and the problems that were experienced are discussed. Details on the computer code are supplied in an appendix

  18. Welding method by remote handling

    International Nuclear Information System (INIS)

    Hashinokuchi, Minoru.

    1994-01-01

    Water is charged into a pit (or a water reservoir) and an article to be welded is placed on a support in the pit by remote handling. A steel plate is disposed so as to cover the article to be welded by remote handling. The welding device is positioned to the portion to be welded and fixed in a state where the article to be welded is shielded from radiation by water and the steel plate. Water in the pit is drained till the portion to be welded is exposed to the atmosphere. Then, welding is conducted. After completion of the welding, water is charged again to the pit and the welding device and fixing jigs are decomposed in a state where the article to be welded is shielded again from radiation by water and the steel plate. Subsequently, the steel plate is removed by remote handling. Then, the article to be welded is returned from the pit to a temporary placing pool by remote handling. This can reduce operator's exposure. Further, since the amount of the shielding materials can be minimized, the amount of radioactive wastes can be decreased. (I.N.)

  19. Probabilistic assessment of the potential indoor air impacts of vent-free gas heating appliances in energy-efficient homes in the United States.

    Science.gov (United States)

    Whitmyre, Gary K; Pandian, Muhilan D

    2018-06-01

    Use of vent-free gas heating appliances for supplemental heating in U.S. homes is increasing. However, there is currently a lack of information on the potential impact of these appliances on indoor air quality for homes constructed according to energy-efficient and green building standards. A probabilistic analysis was conducted to estimate the impact of vent-free gas heating appliances on indoor air concentrations of carbon monoxide (CO), nitrogen dioxide (NO 2 ), carbon dioxide (CO 2 ), water vapor, and oxygen in "tight" energy-efficient homes in the United States. A total of 20,000 simulations were conducted for each Department of Energy (DOE) heating region to capture a wide range of home sizes, appliance features, and conditions, by varying a number of parameters, e.g., room volume, house volume, outdoor humidity, air exchange rates, appliance input rates (Btu/hr), and house heat loss factors. Predicted airborne levels of CO were below the U.S. Environmental Protection Agency (EPA) standard of 9 ppm for all modeled cases. The airborne concentrations of NO 2 were below the U.S. Consumer Product Safety Commission (CPSC) guideline of 0.3 ppm and the Health Canada benchmark of 0.25 ppm in all cases and were below the World Health Organization (WHO) standard of 0.11 ppm in 99-100% of all cases. Predicted levels of CO 2 were below the Health Canada standard of 3500 ppm for all simulated cases. Oxygen levels in the room of vent-free heating appliance use were not significantly reduced. The great majority of cases in all DOE regions were associated with relative humidity (RH) levels from all indoor water vapor sources that were less than the EPA-recommended 70% RH maximum to avoid active mold and mildew growth. The conclusion of this investigation is that when installed in accordance with the manufacturer's instructions, vent-free gas heating appliances maintain acceptable indoor air quality in tight energy-efficient homes, as defined by the standards referenced in

  20. An outbreak of Serratia marcescens infection in a special-care baby unit of a community hospital in United Arab Emirates: the importance of the air conditioner duct as a nosocomial reservoir.

    Science.gov (United States)

    Uduman, S A; Farrukh, A S; Nath, K N R; Zuhair, M Y H; Ifrah, A; Khawla, A D; Sunita, P

    2002-11-01

    We report an outbreak of Serratia marcescens infection in a special-care baby unit (SCBU) of a university-affiliated community hospital in the United Arab Emirates. The outbreak involved 36 infants and lasted for 20 weeks. Seven of the colonized infants developed invasive illnesses in the form of bacteraemia (four cases), bacteraemic meningitis (two) and clinical sepsis (one). Three other term infants had purulent conjunctivitis. There were five deaths with an overall mortality of 14%. S. marcescens was cultured from airflow samples from the air conditioning (AC) which was the reservoir of infection in this outbreak. Elimination of the nosocomial source and outbreak containment were eventually achieved by specialized robotic cleaning of the entire AC duct system of the SCBU. Strict adherence to the infection control policies was reinforced to prevent transmission of cross-infection. Copyright 2002 The Hospital Infection Society

  1. Efektivitas Unit Pengolahan Air di Depot Air Minum Isi Ulang (DAMIU Dalam Menurunkan Kadar Logam (Fe, Mn dan Mikroba di Kota Pekalongan

    Directory of Open Access Journals (Sweden)

    Rosmiati Saleh

    2013-12-01

    Full Text Available Background:The number of drinking-water-refill center were increasing only in quantity but not in providing the quality of water. Therefore it takes a special handling and attention, not only because the low-quality of water causing various diseases.The data from the Pekalongan City Health servic showed that only 13 of 55 drinking-water-refill center (24% which have actively examined their sample water each month in bacteriological test, 3 of them (20% proved to be unqualified. Furthermore, while for chemical examination, there were only 6 (11% which actively doing it, and 2 of them (33% mentioned as unqualified. After doing examination to the raw water, it was found that the content of Fe metal was 2.51 mg/1, Mn metal was 2.41 mg/1, the parameters found was beyond the standard. Methode:The kind of research held was explanatory research using cross sectional design. The sample was taken by proportional sampling. The number of samples was 35 refill centers.The data would be analyzed uding Chi-Square,pairedt-test,Kruskall Wallis, McNemar Test and multivariate test (Logistc regression. Result:The results of this research showed that 23 samples (66% had an unqualified Fe metal content with the average content was 0,34 mg/l, 19 samples (54% had an unqualified Mn metal content, with the average content was 0.47 mg/1, 26 samples (74% with The unqualified quality of E.coli. The other test carried out in the drinking-water refill, resulted that 25 samples (71% had a qualified Fe metal content, the average was 0.29/1 and 22 samples (63% had a qualified E.coli content.The results of Bivariate analysis showed that the condition of raw water, the equipment, the processing, the sanitation, the SOP compliance, significantly related to the decreasing of Fe, Mn metal content and E.coli (p. <0.05. While the results of the multivariate analysis from 5 variables, 1 of which were statistically proven that there was a asosiation relationship between raw water

  2. 7 CFR 905.9 - Handle or ship.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Handle or ship. 905.9 Section 905.9 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... contiguous States and the District of Columbia of the United States to any destination. [54 FR 37292, Sept. 8...

  3. Computer Model to Estimate Reliability Engineering for Air Conditioning Systems

    International Nuclear Information System (INIS)

    Afrah Al-Bossly, A.; El-Berry, A.; El-Berry, A.

    2012-01-01

    Reliability engineering is used to predict the performance and optimize design and maintenance of air conditioning systems. Air conditioning systems are expose to a number of failures. The failures of an air conditioner such as turn on, loss of air conditioner cooling capacity, reduced air conditioning output temperatures, loss of cool air supply and loss of air flow entirely can be due to a variety of problems with one or more components of an air conditioner or air conditioning system. Forecasting for system failure rates are very important for maintenance. This paper focused on the reliability of the air conditioning systems. Statistical distributions that were commonly applied in reliability settings: the standard (2 parameter) Weibull and Gamma distributions. After distributions parameters had been estimated, reliability estimations and predictions were used for evaluations. To evaluate good operating condition in a building, the reliability of the air conditioning system that supplies conditioned air to the several The company's departments. This air conditioning system is divided into two, namely the main chilled water system and the ten air handling systems that serves the ten departments. In a chilled-water system the air conditioner cools water down to 40-45 degree F (4-7 degree C). The chilled water is distributed throughout the building in a piping system and connected to air condition cooling units wherever needed. Data analysis has been done with support a computer aided reliability software, this is due to the Weibull and Gamma distributions indicated that the reliability for the systems equal to 86.012% and 77.7% respectively. A comparison between the two important families of distribution functions, namely, the Weibull and Gamma families was studied. It was found that Weibull method performed for decision making.

  4. Piercing the Fog: Intelligence and Army Air Forces Operations in World War 2

    Science.gov (United States)

    1996-01-01

    Maj Ansel E. M. Talbert, in SRH-023, p. 26. 28. Intvw, Dr. Robert C. Ehrhart with Gen Robert M. Lee, May 21,1988, p. 2. 29. Intvw, Dr. Robert C...Martin for Air Intel Div (Col Adams ), subj: Strategic Vulnerability of the United States, Sep 27, 93. Memo, G-2, with cvr Itr of Maj Virgil 0. Johnson...6673,6.6.44, 23562. 51. PRO 31/20/16; Maj Ansel M. Tal- bert, U.S. Army Air Corps, “Handling of ULTRA Information at Headquarters Eighth Air Force,” in

  5. VVER NPPs fuel handling machine control system

    International Nuclear Information System (INIS)

    Mini, G.; Rossi, G.; Barabino, M.; Casalini, M.

    2002-01-01

    In order to increase the safety level of the fuel handling machine on WWER NPPs, Ansaldo Nucleare was asked to design and supply a new Control System. Two Fuel Handling Machine (FHM) Control System units have been already supplied for Temelin NPP and others supply are in process for the Atommash company, which has in charge the supply of FHMs for NPPs located in Russia, Ukraine and China.The computer-based system takes into account all the operational safety interlocks so that it is able to avoid incorrect and dangerous manoeuvres in the case of operator error. Control system design criteria, hardware and software architecture, and quality assurance control, are in accordance with the most recent international requirements and standards, and in particular for electromagnetic disturbance immunity demands and seismic compatibility. The hardware architecture of the control system is based on ABB INFI 90 system. The microprocessor-based ABB INFI 90 system incorporates and improves upon many of the time proven control capabilities of Bailey Network 90, validated over 14,000 installations world-wide.The control system complies all the former designed sensors and devices of the machine and markedly the angular position measurement sensors named 'selsyn' of Russian design. Nevertheless it is fully compatible with all the most recent sensors and devices currently available on the market (for ex. Multiturn absolute encoders).All control logic were developed using standard INFI 90 Engineering Work Station, interconnecting blocks extracted from an extensive SAMA library by using a graphical approach (CAD) and allowing and easier intelligibility, more flexibility and updated and coherent documentation. The data acquisition system and the Man Machine Interface are implemented by ABB in co-operation with Ansaldo. The flexible and powerful software structure of 1090 Work-stations (APMS - Advanced Plant Monitoring System, or Tenore NT) has been successfully used to interface the

  6. Uranium hexafluoride: A manual of good handling practices. Revision 7

    International Nuclear Information System (INIS)

    1995-01-01

    The United States Enrichment Corporation (USEC) is continuing the policy of the US Department of Energy (DOE) and its predecessor agencies in sharing with the nuclear industry their experience in the area of uranium hexafluoride (UF 6 ) shipping containers and handling procedures. The USEC has reviewed Revision 6 or ORO-651 and is issuing this new edition to assure that the document includes the most recent information on UF 6 handling procedures and reflects the policies of the USEC. This manual updates the material contained in earlier issues. It covers the essential aspects of UF 6 handling, cylinder filling and emptying, general principles of weighing and sampling, shipping, and the use of protective overpacks. The physical and chemical properties of UF 6 are also described. The procedures and systems described for safe handling of UF 6 presented in this document have been developed and evaluated during more than 40 years of handling vast quantities of UF 6 . With proper consideration for its nuclear properties, UF 6 may be safely handled in essentially the same manner as any other corrosive and/or toxic chemical

  7. Uranium hexafluoride: A manual of good handling practices. Revision 7

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-01-01

    The United States Enrichment Corporation (USEC) is continuing the policy of the US Department of Energy (DOE) and its predecessor agencies in sharing with the nuclear industry their experience in the area of uranium hexafluoride (UF{sub 6}) shipping containers and handling procedures. The USEC has reviewed Revision 6 or ORO-651 and is issuing this new edition to assure that the document includes the most recent information on UF{sub 6} handling procedures and reflects the policies of the USEC. This manual updates the material contained in earlier issues. It covers the essential aspects of UF{sub 6} handling, cylinder filling and emptying, general principles of weighing and sampling, shipping, and the use of protective overpacks. The physical and chemical properties of UF{sub 6} are also described. The procedures and systems described for safe handling of UF{sub 6} presented in this document have been developed and evaluated during more than 40 years of handling vast quantities of UF{sub 6}. With proper consideration for its nuclear properties, UF{sub 6} may be safely handled in essentially the same manner as any other corrosive and/or toxic chemical.

  8. The impact of weather changes on air quality and health in the United States in 1994–2012

    Science.gov (United States)

    Jhun, Iny; Coull, Brent A; Schwartz, Joel; Hubbell, Bryan; Koutrakis, Petros

    2016-01-01

    Air quality is heavily influenced by weather conditions. In this study, we assessed the impact of long-term weather changes on air quality and health in the US during 1994–2012. We quantified past weather-related increases, or ‘weather penalty’, in ozone (O3) and fine particulate matter (PM2.5), and thereafter estimated the associated excess deaths. Using statistical regression methods, we derived the weather penalty as the additional increases in air pollution relative to trends assuming constant weather conditions (i.e., weather-adjusted trends). During our study period, temperature increased and wind speed decreased in most US regions. Nationally, weather-related 8 h max O3 increases were 0.18 ppb per year (95% CI: 0.06, 0.31) in the warm season (May–October) and 0.07 ppb per year (95% CI: 0.02, 0.13) in the cold season (November–April). The weather penalties on O3 were relatively larger than PM2.5 weather penalties, which were 0.056 µg m−3 per year (95% CI: 0.016, 0.096) in warm months and 0.027 µg m−3 per year (95% CI: 0.010, 0.043) in cold months. Weather penalties on O3 and PM2.5 were associated with 290 (95% CI: 80, 510) and 770 (95% CI: 190, 1350) excess annual deaths, respectively. Over a 19-year period, this amounts to 20 300 excess deaths (5600 from O3, 14 700 from PM2.5) attributable to the weather penalty on air quality PMID:27570539

  9. The impact of weather changes on air quality and health in the United States in 1994–2012

    International Nuclear Information System (INIS)

    Jhun, Iny; Schwartz, Joel; Koutrakis, Petros; Coull, Brent A; Hubbell, Bryan

    2015-01-01

    Air quality is heavily influenced by weather conditions. In this study, we assessed the impact of long-term weather changes on air quality and health in the US during 1994–2012. We quantified past weather-related increases, or ‘weather penalty’, in ozone (O 3 ) and fine particulate matter (PM 2.5 ), and thereafter estimated the associated excess deaths. Using statistical regression methods, we derived the weather penalty as the additional increases in air pollution relative to trends assuming constant weather conditions (i.e., weather-adjusted trends). During our study period, temperature increased and wind speed decreased in most US regions. Nationally, weather-related 8 h max O 3 increases were 0.18 ppb per year (95% CI: 0.06, 0.31) in the warm season (May–October) and 0.07 ppb per year (95% CI: 0.02, 0.13) in the cold season (November–April). The weather penalties on O 3 were relatively larger than PM 2.5 weather penalties, which were 0.056 μgm −3 per year (95% CI: 0.016, 0.096) in warm months and 0.027 μgm −3 per year (95% CI: 0.010, 0.043) in cold months. Weather penalties on O 3 and PM 2.5 were associated with 290 (95% CI: 80, 510) and 770 (95% CI: 190, 1350) excess annual deaths, respectively. Over a 19-year period, this amounts to 20 300 excess deaths (5600 from O 3 , 14 700 from PM 2.5 ) attributable to the weather penalty on air quality. (letter)

  10. The impact of weather changes on air quality and health in the United States in 1994-2012

    Science.gov (United States)

    Jhun, Iny; Coull, Brent A.; Schwartz, Joel; Hubbell, Bryan; Koutrakis, Petros

    2015-08-01

    Air quality is heavily influenced by weather conditions. In this study, we assessed the impact of long-term weather changes on air quality and health in the US during 1994-2012. We quantified past weather-related increases, or ‘weather penalty’, in ozone (O3) and fine particulate matter (PM2.5), and thereafter estimated the associated excess deaths. Using statistical regression methods, we derived the weather penalty as the additional increases in air pollution relative to trends assuming constant weather conditions (i.e., weather-adjusted trends). During our study period, temperature increased and wind speed decreased in most US regions. Nationally, weather-related 8 h max O3 increases were 0.18 ppb per year (95% CI: 0.06, 0.31) in the warm season (May-October) and 0.07 ppb per year (95% CI: 0.02, 0.13) in the cold season (November-April). The weather penalties on O3 were relatively larger than PM2.5 weather penalties, which were 0.056 μg m-3 per year (95% CI: 0.016, 0.096) in warm months and 0.027 μg m-3 per year (95% CI: 0.010, 0.043) in cold months. Weather penalties on O3 and PM2.5 were associated with 290 (95% CI: 80, 510) and 770 (95% CI: 190, 1350) excess annual deaths, respectively. Over a 19-year period, this amounts to 20 300 excess deaths (5600 from O3, 14 700 from PM2.5) attributable to the weather penalty on air quality.

  11. A Delphi Study Using Value-Focused Thinking for United States Air Force Mission Dependency Index Values

    Science.gov (United States)

    2015-03-26

    intended to allow for a more transparent and effective funding model as part of the new system. One of the models the Air Force considered but did not...conditions and commander’s preferences are accounted for by the other metrics applied to the funding model . The research goal was to correct the...metric for the SRM funding model . (MDI is 60% and the MAJCOM Priority is 40%) i. Does the MAJCOM priority adequately account for the local

  12. Evaluation of Aqua MODIS Collection 6 AOD Parameters for Air Quality Research over the Continental United States

    Directory of Open Access Journals (Sweden)

    J. H. Belle

    2016-10-01

    Full Text Available Satellite-retrieved aerosol optical depth (AOD has become an important predictor of ground-level particulate matter (PM and greatly empowered air pollution research worldwide. We evaluated the AOD parameters included in the Collection 6 aerosol product of the Moderate Resolution Imaging Spectroradiometer (MODIS for two key factors affecting their applications in air quality research—coverage and accuracy—over the continental US. For the high confidence retrievals (QAC 3, the 10 km DB-DT combined AOD has the best coverage nationwide (29.7% of the days in a year in any given 12 km grid cell. While the Eastern US generally had more successful AOD retrievals, the highest spatial coverage of AOD parameters were found in California (>55% and other vegetated parts of the Western US. If lower QAC retrievals were included, the coverage of the 10 km DB AOD was dramatically increased to 49.6%. In the Eastern US, the QAC 3 retrievals of all four AOD parameters are highly correlated with AERONET observations (correlation coefficients between 0.80 and 0.92. In the Western US, positive retrieval errors existed in all MODIS AOD parameters, resulting in lower correlations with AERONET. AOD retrieval errors showed significant dependence on flight geometry, land cover type, and weather conditions. To ensure appropriate use of these AOD values, air quality researchers should carefully balance the needs for coverage and accuracy, and develop additional data screening criteria based on their study design.

  13. Software for the Design of Swimming Pool Dehumidifiers Units

    Science.gov (United States)

    Rubina, Aleš; Blasinski, Petr; Tesař, Zdeněk

    2013-06-01

    The article deals with the description and solution of physical phenomena taking place during evaporation of water. The topicality of the theme is given a number of built indoor swimming pool and wellness centers at present. In addressing HVAC systems serving these areas, it is necessary to know the various design parameters in the interior including the water temperature as the pool temperature and humidity. Following is a description of the calculation module, air handling units, including optimizing the settings of the physical changes in order to ensure the lowest energy consumption for air treatment and required maintaining internal microclimate parameters.

  14. [The Necessity and the Current Status of Safe Handling of Anticancer Drugs].

    Science.gov (United States)

    Kanda, Kiyoko

    2017-07-01

    Number of people who handle anticancer drugs in their profession is increasing. Anticancer drugs, which are hazardous drugs(HD), exert cytocidal effects on cancer cells, but many have also been shown to have mutagenicity, teratogenicity and carcinogenicity; therefore, safe handling of anticancer drugs is necessary. In July 2015, the first Japanese guidelines for exposure control measures, namely, the "Joint Guidelines for Safe Handling of Cancer Chemotherapy Drugs", were published jointly by 3 societies. Our guideline is the creation of the Japanese Society of Cancer Nursing(JSCN), Japanese Society of Medical Oncology(JSMO)and Japanese Society of Pharmaceutical Oncology(JASPO)and has a historical significance. This paper states the necessity of safe handling of anticancer drugs, Japan's recent movement of safe handling, the introduction of joint guidelines of safe handling of anticancer drugs, and new movement of safe handling of USP chapter 800 in the United States.

  15. Development of spent fuel remote handling technology

    International Nuclear Information System (INIS)

    Yoon, J. S.; Hong, H. D.; Kim, S. H.

    2004-02-01

    In this research, the remote handling technology is developed for the advanced spent fuel conditioning process which gives a possible solution to deal with the rapidly increasing spent fuels. In detail, a fuel rod slitting device is developed for the decladding of the spent fuel. A series of experiments has been performed to find out the optimal condition of the spent fuel voloxidation which converts the UO 2 pellet into U 3 O 8 powder. The design requirements of the ACP equipment for hot test is established by analysing the modular requirement, radiation hardening and thermal protection of the process equipment, etc. The prototype of the servo manipulator is developed. The manipulator has an excellent performance in terms of the payload to weight ratio that is 30 % higher than that of existing manipulators. To provide reliability and safety of the ACP, the 3 dimensional graphic simulator is developed. Using the simulator the remote handling operation is simulated and as a result, the optimal layout of ACP is obtained. The supervisory control system is designed to control and monitor the several different unit processes. Also the failure monitoring system is developed to detect the possible accidents of the reduction reactor

  16. Solar-powered single-and double-effect directly air-cooled LiBr–H2O absorption prototype built as a single unit

    International Nuclear Information System (INIS)

    Izquierdo, M.; González-Gil, A.; Palacios, E.

    2014-01-01

    Highlights: • This work presents a novel solar cooling air-cooled absorption prototype for buildings. • The solution (LiB r –H 2 O) and the refrigerant (H 2 O) are cooled directly by air. • The cooling is produced from solar energy when operates in single-effect mode. • If the demand is not met the prototype is able to operate in double-effect mode. - Abstract: This work describes an installation in Madrid, Spain, designed to test a new solar-powered air-cooled absorption refrigeration system. This installation essentially consists of a-48 m 2 field of flat-plate solar collectors, a 1500-L hot water storage tank and a single and-double effect air-cooled lithium bromide absorption prototype. Designed and built by our research group, this prototype is able to operate either as a single-effect unit (4.5 kW) or as a double-effect unit (7 kW). In operation as single-effect mode, the prototype is driven by solar energy, whereas in operation as a double effect mode, an external energy source may be used. The prototype’s evaporator is connected to a fan-coil placed inside an 80-m 2 laboratory that represent the average size of a Spanish housing unit. In August 2009, the cooling system was tested in the single-effect operation mode. The results show that the system is able to meet approximately 65% of the laboratory’s seasonal cooling demand, although 100% may be reached for a few days. The prototype can also operate in double-effect mode to meet the cooling demand. In that case, the prototype is fed by thermal oil, which is warmed until it reaches the process temperature in the high-temperature generator. The prototype can operate in either single-effect mode or in double-effect mode or can also operate simultaneously both modes using the components common to both modes, namely, the absorber, evaporator, condenser, solution pumps and control equipment. This paper reports the experimental results from the prototype operating separately in single-effect and

  17. Nuclear hydrogen production and its safe handling

    International Nuclear Information System (INIS)

    Chung, Hongsuk; Paek, Seungwoo; Kim, Kwang-Rag; Ahn, Do-Hee; Lee, Minsoo; Chang, Jong Hwa

    2003-01-01

    An overview of the hydrogen related research presently undertaken at the Korea Atomic Energy Research Institute are presented. These encompass nuclear hydrogen production, hydrogen storage, and the safe handling of hydrogen, High temperature gas-cooled reactors can play a significant role, with respect to large-scale hydrogen production, if used as the provider of high temperature heat in fossil fuel conversion or thermochemical cycles. A variety of potential hydrogen production methods for high temperature gas-cooled reactors were analyzed. They are steam reforming of natural gas, thermochemical cycles, etc. The produced hydrogen should be stored safely. Titanium metal was tested primarily because its hydride has very low dissociation pressures at normal storage temperatures and a high capacity for hydrogen, it is easy to prepare and is non-reactive with air in the expected storage conditions. There could be a number of potential sources of hydrogen evolution risk in a nuclear hydrogen production facility. In order to reduce the deflagration detonation it is necessary to develop hydrogen control methods that are capable of dealing with the hydrogen release rate. A series of experiments were conducted to assess the catalytic recombination characteristics of hydrogen in an air stream using palladium catalysts. (author)

  18. Experience in handling concentrated tritium

    International Nuclear Information System (INIS)

    Holtslander, W.J.

    1985-12-01

    The notes describe the experience in handling concentrated tritium in the hydrogen form accumulated in the Chalk River Nuclear Laboratories Tritium Laboratory. The techniques of box operation, pumping systems, hydriding and dehydriding operations, and analysis of tritium are discussed. Information on the Chalk River Tritium Extraction Plant is included as a collection of reprints of papers presented at the Dayton Meeting on Tritium Technology, 1985 April 30 - May 2

  19. International handling of fissionable material

    International Nuclear Information System (INIS)

    1975-01-01

    The opinion of the ministry for foreign affairs on international handling of fissionable materials is given. As an introduction a survey is given of the possibilities to produce nuclear weapons from materials used in or produced by power reactors. Principles for international control of fissionable materials are given. International agreements against proliferation of nuclear weapons are surveyed and methods to improve them are proposed. (K.K.)

  20. Remote handling equipment for SNS

    International Nuclear Information System (INIS)

    Poulten, B.H.

    1983-01-01

    This report gives information on the areas of the SNS, facility which become highly radioactive preventing hands-on maintenance. Levels of activity are sufficiently high in the Target Station Area of the SNS, especially under fault conditions, to warrant reactor technology to be used in the design of the water, drainage and ventilation systems. These problems, together with the type of remote handling equipment required in the SNS, are discussed

  1. Remote handling in reprocessing plants

    International Nuclear Information System (INIS)

    Streiff, G.

    1984-01-01

    Remote control will be the rule for maintenance in hot cells of future spent fuel reprocessing plants because of the radioactivity level. New handling equipments will be developed and intervention principles defined. Existing materials, recommendations for use and new manipulators are found in the PMDS' documentation. It is also a help in the choice and use of intervention means and a guide for the user [fr

  2. Enteral Feeding Set Handling Techniques.

    Science.gov (United States)

    Lyman, Beth; Williams, Maria; Sollazzo, Janet; Hayden, Ashley; Hensley, Pam; Dai, Hongying; Roberts, Cristine

    2017-04-01

    Enteral nutrition therapy is common practice in pediatric clinical settings. Often patients will receive a pump-assisted bolus feeding over 30 minutes several times per day using the same enteral feeding set (EFS). This study aims to determine the safest and most efficacious way to handle the EFS between feedings. Three EFS handling techniques were compared through simulation for bacterial growth, nursing time, and supply costs: (1) rinsing the EFS with sterile water after each feeding, (2) refrigerating the EFS between feedings, and (3) using a ready-to-hang (RTH) product maintained at room temperature. Cultures were obtained at baseline, hour 12, and hour 21 of the 24-hour cycle. A time-in-motion analysis was conducted and reported in average number of seconds to complete each procedure. Supply costs were inventoried for 1 month comparing the actual usage to our estimated usage. Of 1080 cultures obtained, the overall bacterial growth rate was 8.7%. The rinse and refrigeration techniques displayed similar bacterial growth (11.4% vs 10.3%, P = .63). The RTH technique displayed the least bacterial growth of any method (4.4%, P = .002). The time analysis in minutes showed the rinse method was the most time-consuming (44.8 ± 2.7) vs refrigeration (35.8 ± 2.6) and RTH (31.08 ± 0.6) ( P refrigerating the EFS between uses is the next most efficacious method for handling the EFS between bolus feeds.

  3. The Characteristics of Cold Air Outbreaks in the Eastern United States and the Influence of Atmospheric Circulation Patterns

    Science.gov (United States)

    Smith, E. T.

    2017-12-01

    Periods of extreme cold impact the mid-latitudes every winter. Depending on the magnitude and duration of the occurrence, extremely cold periods may be deemed cold air outbreaks (CAOs). Atmospheric teleconnections impact the displacement of polar air, but the relationship between the primary teleconnections and the manifestation of CAOs is not fully understood. A systematic CAO index was developed from 20 surface weather stations based on a set of criteria concerning magnitude, duration, and spatial extent. Statistical analyses of the data were used to determine the overall trends in CAOs. Clusters of sea level pressure (SLP), 100mb, and 10mb geopotential height anomalies were mapped utilizing self-organizing maps (SOMs) to understand the surface, upper-tropospheric Polar Vortex (PV), and stratospheric PV patterns preceding CAOs. The Arctic Oscillation (AO), North Atlantic Oscillation (NAO), and Pacific-North American (PNA) teleconnections were used as variables to explain the magnitude and location of mid-latitude Arctic air displacement. Persistently negative SLP anomalies across the Arctic and North Atlantic were evident 1 - 2 weeks prior to the CAOs throughout the winter. The upper-tropospheric and stratospheric PV were found to be persistently weak/weakening prior to mid-winter CAOs and predominantly strong and off-centered prior to early and late season CAOs. Negative phases of the AO and NAO were favored prior to CAOs, while the PNA favored a near-neutral phase. This method of CAO and synoptic pattern characterization benefits from a continuous pattern representation and provides insight as to how specific teleconnections impact the atmospheric flow in a way that leads to CAOs in the eastern U.S.

  4. New, clean handling process introduced to improve cable quality

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, C G

    1990-05-01

    The clean room system introduced by Canada Wire and Cable Limited in its Toronto plant for its cable manufacturing operation is described. While clean room technology is common in the food processing industry, optical and aerospace manufacturing processes, this is the first time it has been applied to wire and cable extrusion in North America. The purpose of the clean compound handling system is to prevent particle contamination in the shielding and cable insulation materials, as part of an effort to prevent premature underground electric cable failures. Two rooms are dedicated to handling different types of insulation compound, two are dedicated to receiving semi-conducting shielding material, and the fifth room functions as an air lock for the two insulation rooms. The atmosphere is highly regulated with programmable logic control. The air supply filters capture 99.97% of all particles 0.3 microns or larger. The system also maintains air temperature, relative humidity and static pressure. The life variability of cross-linked polyethylene primary distribution cable is dependant on five factors: material purity, extra clean compound handling, cable design, manufacturing process, and installation and operation practices. The clean room system is expected to result in cable that is more resistant to water treeing failures. 2 figs.

  5. Feasibility of coupled empirical and dynamic modeling to assess climate change and air pollution impacts on temperate forest vegetation of the eastern United States.

    Science.gov (United States)

    McDonnell, T C; Reinds, G J; Sullivan, T J; Clark, C M; Bonten, L T C; Mol-Dijkstra, J P; Wamelink, G W W; Dovciak, M

    2018-03-01

    Changes in climate and atmospheric nitrogen (N) deposition caused pronounced changes in soil conditions and habitat suitability for many plant species over the latter half of the previous century. Such changes are expected to continue in the future with anticipated further changing air temperature and precipitation that will likely influence the effects of N deposition. To investigate the potential long-term impacts of atmospheric N deposition on hardwood forest ecosystems in the eastern United States in the context of climate change, application of the coupled biogeochemical and vegetation community model VSD+PROPS was explored at three sites in New Hampshire, Virginia, and Tennessee. This represents the first application of VSD+PROPS to forest ecosystems in the United States. Climate change and elevated (above mid-19th century) N deposition were simulated to be important factors for determining habitat suitability. Although simulation results suggested that the suitability of these forests to support the continued presence of their characteristic understory plant species might decline by the year 2100, low data availability for building vegetation response models with PROPS resulted in uncertain results at the extremes of simulated N deposition. Future PROPS model development in the United States should focus on inclusion of additional foundational data or alternate candidate predictor variables to reduce these uncertainties. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Thermal construction unit activation with supply air gains significance. Ceilings cooling - supply air heating - more than 50 % energy conservation; Thermische Bauteilaktivierung mit Zuluft gewinnt an Bedeutung. Decke kuehlen - Zuluft erwaermen - mehr als 50% Energie einsparen

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, Wolfgang

    2009-05-15

    In the year 2001, in Stuttgart (Federal Republic of Germany) the first office building was established which uses a thermal construction unit activation with air as cooling agent. Today, the system ''Concret-cool'' already is installed in more than 40 buildings. Computations show that due to the room heating by means of internally finned ventilation pipes embedded in concrete more than 50 % less energy in comparison to comparable systems can be used. In his Green Building project ''Skyline Tower'' in Munich (Federal Republic of Germany), also star architect Helmut Jahn uses the know-how of the manufacturer of ventilation systems from Stuttgart. As one of the first multi-storied buildings in Munich, ''Skyline Tower'' with its 23 floors was prized with the pre-certificate of the German quality seal ''sustainable building ''in gold.

  7. Changes in Transportation-Related Air Pollution Exposures by Race-Ethnicity and Socioeconomic Status: Outdoor Nitrogen Dioxide in the United States in 2000 and 2010.

    Science.gov (United States)

    Clark, Lara P; Millet, Dylan B; Marshall, Julian D

    2017-09-14

    Disparities in exposure to air pollution by race-ethnicity and by socioeconomic status have been documented in the United States, but the impacts of declining transportation-related air pollutant emissions on disparities in exposure have not been studied in detail. This study was designed to estimate changes over time (2000 to 2010) in disparities in exposure to outdoor concentrations of a transportation-related air pollutant, nitrogen dioxide (NO2), in the United States. We combined annual average NO2 concentration estimates from a temporal land use regression model with Census demographic data to estimate outdoor exposures by race-ethnicity, socioeconomic characteristics (income, age, education), and by location (region, state, county, urban area) for the contiguous United States in 2000 and 2010. Estimated annual average NO2 concentrations decreased from 2000 to 2010 for all of the race-ethnicity and socioeconomic status groups, including a decrease from 17.6 ppb to 10.7 ppb (-6.9 ppb) in nonwhite [non-(white alone, non-Hispanic)] populations, and 12.6 ppb to 7.8 ppb (-4.7 ppb) in white (white alone, non-Hispanic) populations. In 2000 and 2010, disparities in NO2 concentrations were larger by race-ethnicity than by income. Although the national nonwhite-white mean NO2 concentration disparity decreased from a difference of 5.0 ppb in 2000 to 2.9 ppb in 2010, estimated mean NO2 concentrations remained 37% higher for nonwhites than whites in 2010 (40% higher in 2000), and nonwhites were 2.5 times more likely than whites to live in a block group with an average NO2 concentration above the WHO annual guideline in 2010 (3.0 times more likely in 2000). Findings suggest that absolute NO2 exposure disparities by race-ethnicity decreased from 2000 to 2010, but relative NO2 exposure disparities persisted, with higher NO2 concentrations for nonwhites than whites in 2010. https://doi.org/10.1289/EHP959.

  8. Current US strategy and technologies for spent fuel handling

    International Nuclear Information System (INIS)

    Bennett, P.C.; Stringer, J.B.

    1999-01-01

    The United States Department of Energy has recently completed a topical safety analysis report outlining the design and operation of a Centralized Interim Storage Facility for spent commercial nuclear fuel. During the course of the design, dose assessments indicated the need for remote operation of many of the cask handling operations. Use of robotic equipment was identified as a desirable handling solution that is capable of automating many of the operations to maintain throughput, and sufficiently flexible to handle five or more different storage cask designs in varying numbers on a given day. This paper discusses the facility and the dose assessment leading to this choice, and reviews factors to be considered when choosing robotics or automation. Further, a new computer simulation tool to quantify dose to humans working in radiological environments, the Radiological Environment Modeling System (REMS), is introduced. REMS has been developed to produce a more accurate estimate of dose to radiation workers in new activities with radiological hazards. (author)

  9. 7 CFR 926.9 - Handle.

    Science.gov (United States)

    2010-01-01

    ... the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF AGRICULTURE DATA COLLECTION, REPORTING AND RECORDKEEPING REQUIREMENTS APPLICABLE TO CRANBERRIES NOT SUBJECT TO THE CRANBERRY MARKETING ORDER § 926.9 Handle. Handle...

  10. HMSRP Hawaiian Monk Seal Handling Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains records for all handling and measurement of Hawaiian monk seals since 1981. Live seals are handled and measured during a variety of events...

  11. ERROR HANDLING IN INTEGRATION WORKFLOWS

    Directory of Open Access Journals (Sweden)

    Alexey M. Nazarenko

    2017-01-01

    Full Text Available Simulation experiments performed while solving multidisciplinary engineering and scientific problems require joint usage of multiple software tools. Further, when following a preset plan of experiment or searching for optimum solu- tions, the same sequence of calculations is run multiple times with various simulation parameters, input data, or conditions while overall workflow does not change. Automation of simulations like these requires implementing of a workflow where tool execution and data exchange is usually controlled by a special type of software, an integration environment or plat- form. The result is an integration workflow (a platform-dependent implementation of some computing workflow which, in the context of automation, is a composition of weakly coupled (in terms of communication intensity typical subtasks. These compositions can then be decomposed back into a few workflow patterns (types of subtasks interaction. The pat- terns, in their turn, can be interpreted as higher level subtasks.This paper considers execution control and data exchange rules that should be imposed by the integration envi- ronment in the case of an error encountered by some integrated software tool. An error is defined as any abnormal behavior of a tool that invalidates its result data thus disrupting the data flow within the integration workflow. The main requirementto the error handling mechanism implemented by the integration environment is to prevent abnormal termination of theentire workflow in case of missing intermediate results data. Error handling rules are formulated on the basic pattern level and on the level of a composite task that can combine several basic patterns as next level subtasks. The cases where workflow behavior may be different, depending on user's purposes, when an error takes place, and possible error handling op- tions that can be specified by the user are also noted in the work.

  12. Air Quality System (AQS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Air Quality System (AQS) database contains measurements of air pollutant concentrations from throughout the United States and its territories. The measurements...

  13. Nuclear air cleaning

    International Nuclear Information System (INIS)

    Bellamy, R.R.

    1994-01-01

    This report briefly describes the history of the use of high- efficiency particulate air filters for air cleaning at nuclear installations in the United States and discusses future uses of such filters

  14. LACIE data-handling techniques

    Science.gov (United States)

    Waits, G. H. (Principal Investigator)

    1979-01-01

    Techniques implemented to facilitate processing of LANDSAT multispectral data between 1975 and 1978 are described. The data that were handled during the large area crop inventory experiment and the storage mechanisms used for the various types of data are defined. The overall data flow, from the placing of the LANDSAT orders through the actual analysis of the data set, is discussed. An overview is provided of the status and tracking system that was developed and of the data base maintenance and operational task. The archiving of the LACIE data is explained.

  15. The handling of radiation accidents

    International Nuclear Information System (INIS)

    Macdonald, H.F.; Orchard, H.C.; Walker, C.W.

    1977-04-01

    Some of the more interesting and important contributions to a recent International Symposium on the Handling of Radiation Accidents are discussed and personal comments on many of the papers presented are included. The principal conclusion of the Symposium was that although the nuclear industry has an excellent safety record, there is no room for complacency. Continuing attention to emergency planning and exercising are essential in order to maintain this position. A full list of the papers presented at the Symposium is included as an Appendix. (author)

  16. 7 CFR 58.443 - Whey handling.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Whey handling. 58.443 Section 58.443 Agriculture... Procedures § 58.443 Whey handling. (a) Adequate sanitary facilities shall be provided for the handling of whey. If outside, necessary precautions shall be taken to minimize flies, insects and development of...

  17. A comparative thermodynamic, economic and risk analysis concerning implementation of oxy-combustion power plants integrated with cryogenic and hybrid air separation units

    International Nuclear Information System (INIS)

    Skorek-Osikowska, Anna; Bartela, Łukasz; Kotowicz, Janusz

    2015-01-01

    Highlights: • Mathematical model of an integrated oxy-combustion power plant. • Comparison of a hybrid membrane–cryogenic oxygen generation plant with a cryogenic plant. • Thermodynamic analysis of the modeled cases of the plant. • Comparative economic analysis of the power plant with cryogenic and hybrid ASU. • Comparative risk analysis using a Monte Carlo method and sensitivity analysis. - Abstract: This paper presents a comparison of two types of oxy-combustion power plant that differ from each other in terms of the method of oxygen separation. For the purpose of the analysis, detailed thermodynamic models of oxy-fuel power plants with gross power of approximately 460 MW were built. In the first variant (Case 1), the plant is integrated with a cryogenic air separation unit (ASU). In the second variant (Case 2), the plant is integrated with a hybrid membrane–cryogenic installation. The models were built and optimized using the GateCycle, Aspen Plus and Aspen Custom Modeller software packages and with the use of our own computational codes. The results of the thermodynamic evaluation of the systems, which primarily uses indicators such as the auxiliary power and efficiencies of the whole system and of the individual components that constitute the unit, are presented. Better plant performance is observed for Case 2, which has a net efficiency of electricity generation that is 1.1 percentage points greater than that of Case 1. For the selected structure of the system, an economic analysis of the solutions was made. This analysis accounts for different scenarios of the functioning of the Emission Trading Scheme and includes detailed estimates of the investment costs in both cases. As an indicator of profitability, the break-even price of electricity was used primarily. The results of the analysis for the assumptions made are presented in this paper. A system with a hybrid air separation unit has slightly better economic performance. The break-even price

  18. Fungal colonization of fiberglass insulation in the air distribution system of a multi-story office building: VOC production and possible relationship to a sick building syndrome

    Science.gov (United States)

    Ahearn, D. G.; Crow, S. A.; Simmons, R. B.; Price, D. L.; Noble, J. A.; Mishra, S. K.; Pierson, D. L.

    1996-01-01

    Complaints characteristic of those for sick building syndrome prompted mycological investigations of a modern multi-story office building on the Gulf coast in the Southeastern United States (Houston-Galveston area). The air handling units and fiberglass duct liner of the heating, ventilating and air conditioning system of the building, without a history of catastrophic or chronic water damage, demonstrated extensive colonization with Penicillium spp and Cladosporium herbarum. Although dense fungal growth was observed on surfaces within the heating-cooling system, most air samples yielded fewer than 200 CFU m-3. Several volatile compounds found in the building air were released also from colonized fiberglass. Removal of colonized insulation from the floor receiving the majority of complaints of mouldy air and continuous operation of the units supplying this floor resulted in a reduction in the number of complaints.

  19. Development of monitoring-control methods for heavy remote handling operations in an irradiated environment

    Energy Technology Data Exchange (ETDEWEB)

    Argouac' h, J R [Alsthom-Atlantique, ACB Nantes (France)

    1984-11-01

    Heavy remote handling equipment units have benefited from the progress made in robotics, but with certain specific constraints linked to the environment in which they are required to operate. Notably, these constraints impose the exclusive use of electrical techniques.

  20. The Effect of Central American Smoke Aerosols on the Air Quality and Climate over the Southeastern United States: First Results from RAMS-AROMA

    Science.gov (United States)

    Wang, J.; Christopher, S. A.; Nair, U. S.; Reid, J.; Prins, E. M.; Szykman, J.

    2004-12-01

    Observation shows that smoke aerosols from biomass burning activities in Central America can be transported to the Southeastern United States (SEUS). In this study, the Regional Atmospheric Modeling System - Assimilation and Radiation Online Modeling of Aerosols (RAMS-AROMA) is used to investigate the effect of transported smoke aerosols on climate and air quality over the SEUS. AROMA is an aerosol transport model with capabilities of online integration of aerosol radiation effects and online assimilation of satellite-derived aerosol and emission products. It is assembled within the RAMS, so two-way interactions between aerosol fields and other meteorology fields are achieved simultaneously during each model time step. RAMS-AROMA is a unique tool that can be used to examine the aerosol radiative impacts on the surface energy budget and atmospheric heating rate and to investigate how atmospheric thermal and dynamical processes respond to such impacts and consequently affect the aerosol distribution (so called feedbacks). First results regarding air quality effects and radiative forcing of transported smoke aerosols will be presented from RAMS-AROMA based on assimilation of smoke emission products from the Fire Locating and Modeling of Burning Emissions (FLAMBE) project and aerosol optical thickness data derived from the MODIS instrument on the Terra and Aqua satellites. Comparisons with PM2.5 data collected from the EPA observation network and the aerosol optical thickness data from the DOE Atmosphere Radiation Measurements in the Southern Great Plains (ARM SGP) showed that RAMS-AROMA can predict the timing and spatial distribution of smoke events very well, with an accuracy useful for air quality forecasts. The smoke radiative effects on the surface temperature and atmospheric heating rate as well as their feedbacks will also be discussed.

  1. Building a Quality Controlled Database of Meteorological Data from NASA Kennedy Space Center and the United States Air Force's Eastern Range

    Science.gov (United States)

    Brenton, James C.; Barbre. Robert E., Jr.; Decker, Ryan K.; Orcutt, John M.

    2018-01-01

    The National Aeronautics and Space Administration's (NASA) Marshall Space Flight Center (MSFC) Natural Environments Branch (EV44) has provided atmospheric databases and analysis in support of space vehicle design and day-of-launch operations for NASA and commercial launch vehicle programs launching from the NASA Kennedy Space Center (KSC), co-located on the United States Air Force's Eastern Range (ER) at the Cape Canaveral Air Force Station. The ER complex is one of the most heavily instrumented sites in the United States with over 31 towers measuring various atmospheric parameters on a continuous basis. An inherent challenge with large sets of data consists of ensuring erroneous data is removed from databases, and thus excluded from launch vehicle design analyses. EV44 has put forth great effort in developing quality control (QC) procedures for individual meteorological instruments, however no standard QC procedures for all databases currently exists resulting in QC databases that have inconsistencies in variables, methodologies, and periods of record. The goal of this activity is to use the previous efforts by EV44 to develop a standardized set of QC procedures from which to build meteorological databases from KSC and the ER, while maintaining open communication with end users from the launch community to develop ways to improve, adapt and grow the QC database. Details of the QC procedures will be described. As the rate of launches increases with additional launch vehicle programs, it is becoming more important that weather databases are continually updated and checked for data quality before use in launch vehicle design and certification analyses.

  2. Analysis of an integrated cryogenic air separation unit, oxy-combustion carbon dioxide power cycle and liquefied natural gas regasification process by exergoeconomic method

    International Nuclear Information System (INIS)

    Mehrpooya, Mehdi; Zonouz, Masood Jalali

    2017-01-01

    Highlights: • Exergoeconomic analyses is done on an integrated cryogenic air separation unit. • Liquefied natural gas cold energy is used in the process. • The main multi stream heat exchanger is the worst device based on the results. - Abstract: Exergoeconomic and sensitivity analyses are performed on the integrated cryogenic air separation unit, oxy-combustion Carbon dioxide power cycle and liquefied natural gas regasification process. Exergy destruction, exergy efficiency, cost rate of exergy destruction, cost rate of capital investment and operating and maintenance, exergoeconomic factor and relative cost difference have been calculated for the major components of the process. The exergy efficiency of the process is around 67.1% and after mixers, tees, tank and expansion valves the multi-stream heat exchanger H-3 have the best exergy efficiency among all process components. Total exergy destruction rate of the process is 1.93 × 10"7 kW. Results of exergoeconomic analysis demonstrates that maximum exergy destruction and capital investment operating and maintenance cost rate are related to the multi-stream heat exchanger H-1 and pump P-1 with the values of 335,144 ($/h) and 12,838 ($/h), respectively. In the sensitivity analysis section the effects of the varying economic parameters, such as interest rate and plant life time are investigated on the trend of the capital investment operating and maintenance cost rate of the major components of the process and in another cases the effect of the gas turbine isentropic efficiency on the exergy and exergoeconomic parameters are studied.

  3. Shale gas vs. coal: Policy implications from environmental impact comparisons of shale gas, conventional gas, and coal on air, water, and land in the United States

    International Nuclear Information System (INIS)

    Jenner, Steffen; Lamadrid, Alberto J.

    2013-01-01

    The aim of this paper is to examine the major environmental impacts of shale gas, conventional gas and coal on air, water, and land in the United States. These factors decisively affect the quality of life (public health and safety) as well as local and global environmental protection. Comparing various lifecycle assessments, this paper will suggest that a shift from coal to shale gas would benefit public health, the safety of workers, local environmental protection, water consumption, and the land surface. Most likely, shale gas also comes with a smaller GHG footprint than coal. However, shale gas extraction can affect water safety. This paper also discusses related aspects that exemplify how shale gas can be more beneficial in the short and long term. First, there are technical solutions readily available to fix the most crucial problems of shale gas extraction, such as methane leakages and other geo-hazards. Second, shale gas is best equipped to smoothen the transition to an age of renewable energy. Finally, this paper will recommend hybrid policy regulations. - Highlights: ► We examine the impacts of (un)conventional gas and coal on air, water, and land. ► A shift from coal to shale gas would benefit public health. ► Shale gas extraction can affect water safety. ► We discuss technical solutions to fix the most crucial problems of shale gas extraction. ► We recommend hybrid regulations.

  4. Liver dysfunction among workers handling 5-nitro-o-toluidine.

    Science.gov (United States)

    Shimizu, H; Kumada, T; Nakano, S; Kiriyama, S; Sone, Y; Honda, T; Watanabe, K; Nakano, I; Fukuda, Y; Hayakawa, T

    2002-02-01

    5-Nitro-o-toluidine is an aromatic nitro amino compound. While other aromatic compounds are known to damage the human liver and are registered as toxic substances, toxicity information concerning 5-nitro-o-toluidine is lacking. To investigate the hepatotoxicity of 5-nitro-o-toluidine. Of 15 workers in the same factory who handled 5-nitro-o-toluidine, three were hospitalised with symptoms of acute liver dysfunction. Suspecting a link between liver dysfunction and working conditions, we correlated workplace factors with clinical findings in all 15 workers. Blood biochemistry tests indicated liver damage in seven of 15 study subjects. Workers who handled 5-nitro-o-toluidine and nitrosyl sulphuric acid often loosened their respiratory protective equipment shortly after 5-nitro-o-toluidine powder had been dispersed into the air of the room. No potential hepatotoxins were present except for 5-nitro-o-toluidine. Six of the affected workers had handled 5-nitro-o-toluidine 12 to 20 times; the seventh worker had handled the powder three times; and the other eight workers without liver dysfunction had handled the material once or twice. No other significant differences in background were evident between the affected and unaffected workers, such as age, sex, or protective measures. Histological findings during recovery from liver damage were similar to those of acute viral hepatitis. None of the 15 subjects has demonstrated liver damage since the factory was closed. A link between liver dysfunction and 5-nitro-o-toluidine exposure is suggested by greater severity of liver dysfunction associated with more episodes of handling.

  5. Life cycle air quality impacts of conventional and alternative light-duty transportation in the United States.

    Science.gov (United States)

    Tessum, Christopher W; Hill, Jason D; Marshall, Julian D

    2014-12-30

    Commonly considered strategies for reducing the environmental impact of light-duty transportation include using alternative fuels and improving vehicle fuel economy. We evaluate the air quality-related human health impacts of 10 such options, including the use of liquid biofuels, diesel, and compressed natural gas (CNG) in internal combustion engines; the use of electricity from a range of conventional and renewable sources to power electric vehicles (EVs); and the use of hybrid EV technology. Our approach combines spatially, temporally, and chemically detailed life cycle emission inventories; comprehensive, fine-scale state-of-the-science chemical transport modeling; and exposure, concentration-response, and economic health impact modeling for ozone (O3) and fine particulate matter (PM2.5). We find that powering vehicles with corn ethanol or with coal-based or "grid average" electricity increases monetized environmental health impacts by 80% or more relative to using conventional gasoline. Conversely, EVs powered by low-emitting electricity from natural gas, wind, water, or solar power reduce environmental health impacts by 50% or more. Consideration of potential climate change impacts alongside the human health outcomes described here further reinforces the environmental preferability of EVs powered by low-emitting electricity relative to gasoline vehicles.

  6. WWER NPPs fuel handling machine control system

    International Nuclear Information System (INIS)

    Mini, G.; Rossi, G.; Barabino, M.; Casalini, M.

    2001-01-01

    In order to increase the safety level of the fuel handling machine on WWER NPPs, Ansaldo Nucleare was asked to design and supply a new Control System. Two FHM Control System units have been already supplied for Temelin NPP and others supplies are in process for the Atommash company, which has in charge the supply of FHMs for NPPs located in Russia, Ukraine and China. The Fuel Handling Machine (FHM) Control System is an integrated system capable of a complete management of nuclear fuel assemblies. The computer-based system takes into account all the operational safety interlocks so that it is able to avoid incorrect and dangerous manoeuvres in the case of operator error. Control system design criteria, hardware and software architecture, and quality assurance control, are in accordance with the most recent international requirements and standards, and in particular for electromagnetic disturbance immunity demands and seismic compatibility. The hardware architecture of the control system is based on ABB INFI 90 system. The microprocessor-based ABB INFI 90 system incorporates and improves upon many of the time proven control capabilities of Bailey Network 90, validated over 14,000 installations world-wide. The control system complies all the former designed sensors and devices of the machine and markedly the angular position measurement sensors named 'selsyn' of Russian design. Nevertheless it is fully compatible with all the most recent sensors and devices currently available on the market (for ex. Multiturn absolute encoders). All control logic components were developed using standard INFI 90 Engineering Work Station, interconnecting blocks extracted from an extensive SAMA library by using a graphical approach (CAD) and allowing an easier intelligibility, more flexibility and updated and coherent documentation. The data acquisition system and the Man Machine Interface are implemented by ABB in co-operation with Ansaldo. The flexible and powerful software structure

  7. Remote-handled transuranic waste study

    International Nuclear Information System (INIS)

    1995-10-01

    The Waste Isolation Pilot Plant (WIPP) was developed by the US Department of Energy (DOE) as a research and development facility to demonstrate the safe disposal of transuranic (TRU) radioactive wastes generated from the Nation's defense activities. The WIPP disposal inventory will include up to 250,000 cubic feet of TRU wastes classified as remote handled (RH). The remaining inventory will include contact-handled (CH) TRU wastes, which characteristically have less specific activity (radioactivity per unit volume) than the RH-TRU wastes. The WIPP Land Withdrawal Act (LWA), Public Law 102-579, requires a study of the effect of RH-TRU waste on long-term performance. This RH-TRU Waste Study has been conducted to satisfy the requirements defined by the LWA and is considered by the DOE to be a prudent exercise in the compliance certification process of the WIPP repository. The objectives of this study include: conducting an evaluation of the impacts of RH-TRU wastes on the performance assessment (PA) of the repository to determine the effects of Rh-TRU waste as a part of the total WIPP disposal inventory; and conducting a comparison of CH-TRU and RH-TRU wastes to assess the differences and similarities for such issues as gas generation, flammability and explosiveness, solubility, and brine and geochemical interactions. This study was conducted using the data, models, computer codes, and information generated in support of long-term compliance programs, including the WIPP PA. The study is limited in scope to post-closure repository performance and includes an analysis of the issues associated with RH-TRU wastes subsequent to emplacement of these wastes at WIPP in consideration of the current baseline design. 41 refs

  8. Complying with Clean Air Act acid rain provisions: A case history of required air quality analyses

    International Nuclear Information System (INIS)

    McComb, G.G. Jr.; Naperkoski, G.J.; Rogers, F.A.

    1990-01-01

    Clean Air Act Amendments being considered by Congress require SO 2 emissions reductions from numerous large power generation sources nationwide. As currently written, these amendments also require that the affected sources must continue to comply with all provisions of the existing Clean Air Act while achieving the required reductions. United Engineers and Constructors is presently assisting utilities in the evaluation of compliance options for units totaling over 18,000 MW. The methods of achieving compliance with the probable requirements of the Act most often include the retrofit installation of SO 2 scrubbers. A study designed to determine permitting issues and the scope of air quality analyses required to demonstrate the regulatory acceptability of installation of wet scrubbing systems has been completed for units totaling a portion of the above-referenced 18,000 MW. The study results show that, under certain commonly occurring circumstances, there is a risk of creating National Ambient Air Quality Standards contraventions for SO 2 and NO 2 when scrubbers are installed at an existing facility. Any such contraventions subject the plant to state and/or federal enforcement actions. In addition, installation of materials handling equipment for lime stone can trigger Prevention of Significant Deterioration requirements as a major modification. This paper is divided into two major areas. The first deals with the air quality regulatory requirements imposed upon installation of pollution control equipment. The first section is further sub-divided into two sections: one covering requirements emanating from the 1977 Clean Air Act Amendments and its implementing regulations and the other the regulatory requirements of the new Clean Air Act Amendments. This section on regulatory requirements provides background information for the understanding of the second major section of the paper which gives the results of the hypothetical case study

  9. Transfer Area Mechanical Handling Calculation

    International Nuclear Information System (INIS)

    Dianda, B.

    2004-01-01

    This calculation is intended to support the License Application (LA) submittal of December 2004, in accordance with the directive given by DOE correspondence received on the 27th of January 2004 entitled: ''Authorization for Bechtel SAX Company L.L. C. to Include a Bare Fuel Handling Facility and Increased Aging Capacity in the License Application, Contract Number DE-AC--28-01R W12101'' (Arthur, W.J., I11 2004). This correspondence was appended by further Correspondence received on the 19th of February 2004 entitled: ''Technical Direction to Bechtel SAIC Company L.L. C. for Surface Facility Improvements, Contract Number DE-AC--28-OIRW12101; TDL No. 04-024'' (BSC 2004a). These documents give the authorization for a Fuel Handling Facility to be included in the baseline. The purpose of this calculation is to establish preliminary bounding equipment envelopes and weights for the Fuel Handling Facility (FHF) transfer areas equipment. This calculation provides preliminary information only to support development of facility layouts and preliminary load calculations. The limitations of this preliminary calculation lie within the assumptions of section 5 , as this calculation is part of an evolutionary design process. It is intended that this calculation is superseded as the design advances to reflect information necessary to support License Application. The design choices outlined within this calculation represent a demonstration of feasibility and may or may not be included in the completed design. This calculation provides preliminary weight, dimensional envelope, and equipment position in building for the purposes of defining interface variables. This calculation identifies and sizes major equipment and assemblies that dictate overall equipment dimensions and facility interfaces. Sizing of components is based on the selection of commercially available products, where applicable. This is not a specific recommendation for the future use of these components or their

  10. [A double confinement. The current situation inside the Psychiatric Forensic Unit # 20 of the Hospital "J. T. Borda" of Buenos Aires City].

    Science.gov (United States)

    Guilis, Graciela; Amendolaro, Roxana; Del Do, Adelqui; Wikinski, Mariana; Sobredo, Laura

    2006-01-01

    Imprisonment of offenders with mental disorders in special psychiatric units constitutes a practice expected to satisfy both the legal and medical needs of prisoners. However, the actual conditions in which this practice takes place frequently hinders its purpose. In this work we describe the observations made by members of a Human Right Organization' Mental Health Team, the Centro de Estudios Legales y Sociales (CELS) (Legal and Social Studies Centre), in the Psychiatric Unit of the J. T. Borda Hospital, in Buenos Aires, Argentina. Observations were carried on in three visits performed by a group of psychologists, psychiatrists and lawyers. Visitors interviewed patients and examined the buildings and other material conditions to which patients are submitted. Interviews always took place in front of the guardians. From the interviews and the examination of the installations it can be concluded that: a) patients lack systematic diagnostic and treatment, and b) severe violations to their human rights were documented. So, the imprisonment conditions preclude any therapeutic intervention. The international legislation related to this special clinical and legal situation is revised ant the concepts of "penal state", "control societies" and "total institutions" are discussed.

  11. Identification and control of factors influencing flow-accelerated corrosion in HRSG units using computational fluid dynamics modeling, full-scale air flow testing, and risk analysis

    Energy Technology Data Exchange (ETDEWEB)

    Pietrowski, Ronald L. [The Consolidated Edison Company of New York, Inc., New York, NY (United States)

    2010-11-15

    In 2009, Consolidated Edison's East River heat recovery steam generator units 10 and 20 both experienced economizer tube failures which forced each unit offline. Extensive inspections indicated that the primary failure mechanism was flow-accelerated corrosion (FAC). The inspections revealed evidence of active FAC in all 7 of the economizer modules, with the most advanced stages of degradation being noted in center modules. Analysis determined that various factors were influencing and enabling this corrosion mechanism. Computational fluid dynamics and full-scale air flow testing showed very turbulent feedwater flow prevalent in areas of the modules corresponding with the pattern of FAC damage observed through inspection. It also identified preferential flow paths, with higher flow velocities, in certain tubes directly under the inlet nozzles. A FAC risk analysis identified more general susceptibility to FAC in the areas experiencing damage due to feedwater pH, operating temperatures, local shear fluid forces, and the chemical composition of the original materials of construction. These, in combination, were the primary root causes of the failures. Corrective actions were identified, analyzed, and implemented, resulting in equipment replacements and repairs. (orig.)

  12. The influence of floc size and hydraulic detention time on the performance of a dissolved air flotation (DAF) pilot unit in the light of a mathematical model.

    Science.gov (United States)

    Moruzzi, R B; Reali, M A P

    2014-12-01

    The influence of floc size and hydraulic detention time on the performance of a dissolved air flotation (DAF) pilot unit was investigated in the light of a known mathematical model. The following design and operational parameters were considered: the hydraulic detention time (tdcz) and hydraulic loading rate in the contact zone, the down-flow loading rate in the clarification zone, the particle size distribution (d F), and the recirculation rate (p). As a reference for DAF performance analysis, the proposed β.td parameter from the above mentioned mathematical model was employed. The results indicated that tdcz is an important factor in DAF performance and that d F and floc size are also determinants of DAF efficiency. Further, β.td was sensitive to both design and operational parameters, which were varied in the DAF pilot plant. The performance of the DAF unit decreases with increasing β.td values because a higher td (considering a fixed β) or a higher β (e.g., higher hydrophobicity of the flocs for a fixed td) would be necessary in the reaction zone to reach desired flotation efficiency.

  13. NaK handling and removal

    International Nuclear Information System (INIS)

    Desreumaux, J.; Rodriguez, G.; Guigon, A.; Verdelli, J.; Thomine, G.

    1997-01-01

    Sodium-potassium alloy is used in specific application in French Fast Breeder Reactors as: cold traps, NaK bubbler for argon purification, valves and also in experimental irradiation devices. lt has been preferred to sodium because it is liquid from + 7 deg. C for the most common peritectic alloy. After its use, NaK is considered as a hazardous waste (nuclear or not) due to its high reactivity with air and water. The most important risk remains in handling NaK systems which have not been operated for some time. The NaK will be covered with a crust of the superoxide K02 which is a strong oxidising agent. Thermodynamically, K02 will react with most organic material or metallic dust or swarfs and can also react with additional NaK to give sufficient heat to boil part of the NaK, resulting in a sudden increase in pressure and small explosions. We describe the formation given to experimenters in our Sodium School and the CEA's experience in treating specific devices for transportation, decanting of tanks, tank opening and NaK removal. (author)

  14. Experiences with decontaminating tritium-handling apparatus

    International Nuclear Information System (INIS)

    Maienschein, J.L.; Garcia, F.; Garza, R.G.; Kanna, R.L.; Mayhugh, S.R.; Taylor, D.T.

    1991-07-01

    Tritium-handling apparatus has been decontaminated as part of the shutdown of the LLNL Tritium Facility. Two stainless-steel gloveboxes that had been used to process lithium deuteride-tritide (LiDT) salt were decontaminated using the Portable Cleanup System so that they could be flushed with room air through the facility ventilation system. Further surface decontamination was performed by scrubbing the interior with paper towels and ethyl alcohol or Swish trademark. The surface contamination, as shown by swipe surveys, was reduced from 4x10 4 --10 6 disintegrations per minute (dpm)/cm 2 to 2x10 2 --4x10 4 dpm/cm 2 . Details on the decontamination operation are provided. A series of metal (palladium and vanadium) hydride storage beds have been drained of tritium and flushed with deuterium in order to remove as much tritium as possible. The bed draining and flushing procedure is described, and a calculational method is presented which allows estimation of the tritium remaining in a bed after it has been drained and flushed. Data on specific bed draining and flushing are given

  15. CANISTER HANDLING FACILITY DESCRIPTION DOCUMENT

    Energy Technology Data Exchange (ETDEWEB)

    J.F. Beesley

    2005-04-21

    The purpose of this facility description document (FDD) is to establish requirements and associated bases that drive the design of the Canister Handling Facility (CHF), which will allow the design effort to proceed to license application. This FDD will be revised at strategic points as the design matures. This FDD identifies the requirements and describes the facility design, as it currently exists, with emphasis on attributes of the design provided to meet the requirements. This FDD is an engineering tool for design control; accordingly, the primary audience and users are design engineers. This FDD is part of an iterative design process. It leads the design process with regard to the flowdown of upper tier requirements onto the facility. Knowledge of these requirements is essential in performing the design process. The FDD follows the design with regard to the description of the facility. The description provided in this FDD reflects the current results of the design process.

  16. Bulk handling benefits from ICT

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-11-15

    The efficiency and accuracy of bulk handling is being improved by the range of management information systems and services available today. As part of the program to extend Richards Bay Coal Terminal, Siemens is installing a manufacturing execution system which coordinates and monitors all movements of raw materials. The article also reports recent developments by AXSMarine, SunGuard Energy, Fuelworx and Railworx in providing integrated tools for tracking, managing and optimising solid/liquid fuels and rail car maintenance activities. QMASTOR Ltd. has secured a contract with Anglo Coal Australia to provide its Pit to Port.net{reg_sign} and iFuse{reg_sign} software systems across all their Australians sites, to include pit-to-product stockpile management. 2 figs.

  17. Handling and transport problems (1960)

    International Nuclear Information System (INIS)

    Pomarola, J.; Savouyaud, J.

    1960-01-01

    I. The handling and transport of radioactive wastes involves the danger of irradiation and contamination. It is indispensable: - to lay down a special set of rules governing the removal and transport of wastes within centres or from one centre to another; - to give charge of this transportation to a group containing teams of specialists. The organisation, equipment and output of these teams is being examined. II. Certain materials are particularly dangerous to transport, and for these special vehicles and fixed installations are necessary. This is the case especially for the evacuation of very active liquids. A transport vehicle is described, consisting of a trailer tractor and a recipient holding 500 litres of liquid of which the activity can reach 1000 C/l; the decanting operation, the route to be followed by the vehicle, and the precautions taken are also described. (author) [fr

  18. CANISTER HANDLING FACILITY DESCRIPTION DOCUMENT

    International Nuclear Information System (INIS)

    Beesley. J.F.

    2005-01-01

    The purpose of this facility description document (FDD) is to establish requirements and associated bases that drive the design of the Canister Handling Facility (CHF), which will allow the design effort to proceed to license application. This FDD will be revised at strategic points as the design matures. This FDD identifies the requirements and describes the facility design, as it currently exists, with emphasis on attributes of the design provided to meet the requirements. This FDD is an engineering tool for design control; accordingly, the primary audience and users are design engineers. This FDD is part of an iterative design process. It leads the design process with regard to the flowdown of upper tier requirements onto the facility. Knowledge of these requirements is essential in performing the design process. The FDD follows the design with regard to the description of the facility. The description provided in this FDD reflects the current results of the design process

  19. Fuel Handling Facility Description Document

    International Nuclear Information System (INIS)

    M.A. LaFountain

    2005-01-01

    The purpose of the facility description document (FDD) is to establish the requirements and their bases that drive the design of the Fuel Handling Facility (FHF) to allow the design effort to proceed to license application. This FDD is a living document that will be revised at strategic points as the design matures. It identifies the requirements and describes the facility design as it currently exists, with emphasis on design attributes provided to meet the requirements. This FDD was developed as an engineering tool for design control. Accordingly, the primary audience and users are design engineers. It leads the design process with regard to the flow down of upper tier requirements onto the facility. Knowledge of these requirements is essential to performing the design process. It trails the design with regard to the description of the facility. This description is a reflection of the results of the design process to date

  20. Data Handling and Parameter Estimation

    DEFF Research Database (Denmark)

    Sin, Gürkan; Gernaey, Krist

    2016-01-01

    ,engineers, and professionals. However, it is also expected that they will be useful both for graduate teaching as well as a stepping stone for academic researchers who wish to expand their theoretical interest in the subject. For the models selected to interpret the experimental data, this chapter uses available models from...... literature that are mostly based on the ActivatedSludge Model (ASM) framework and their appropriate extensions (Henze et al., 2000).The chapter presents an overview of the most commonly used methods in the estimation of parameters from experimental batch data, namely: (i) data handling and validation, (ii......Modelling is one of the key tools at the disposal of modern wastewater treatment professionals, researchers and engineers. It enables them to study and understand complex phenomena underlying the physical, chemical and biological performance of wastewater treatment plants at different temporal...