WorldWideScience

Sample records for handling qualities evaluation

  1. Inverse simulation system for evaluating handling qualities during rendezvous and docking

    Science.gov (United States)

    Zhou, Wanmeng; Wang, Hua; Thomson, Douglas; Tang, Guojin; Zhang, Fan

    2017-08-01

    The traditional method used for handling qualities assessment of manned space vehicles is too time-consuming to meet the requirements of an increasingly fast design process. In this study, a rendezvous and docking inverse simulation system to assess the handling qualities of spacecraft is proposed using a previously developed model-predictive-control architecture. By considering the fixed discrete force of the thrusters of the system, the inverse model is constructed using the least squares estimation method with a hyper-ellipsoidal restriction, the continuous control outputs of which are subsequently dispersed by pulse width modulation with sensitivity factors introduced. The inputs in every step are deemed constant parameters, and the method could be considered as a general method for solving nominal, redundant, and insufficient inverse problems. The rendezvous and docking inverse simulation is applied to a nine-degrees-of-freedom platform, and a novel handling qualities evaluation scheme is established according to the operation precision and astronauts' workload. Finally, different nominal trajectories are scored by the inverse simulation and an established evaluation scheme. The scores can offer theoretical guidance for astronaut training and more complex operation missions.

  2. Cooper-Harper Experience Report for Spacecraft Handling Qualities Applications

    Science.gov (United States)

    Bailey, Randall E.; Jackson, E. Bruce; Bilimoria, Karl D.; Mueller, Eric R.; Frost, Chad R.; Alderete, Thomas S.

    2009-01-01

    A synopsis of experience from the fixed-wing and rotary-wing aircraft communities in handling qualities development and the use of the Cooper-Harper pilot rating scale is presented as background for spacecraft handling qualities research, development, test, and evaluation (RDT&E). In addition, handling qualities experiences and lessons-learned from previous United States (US) spacecraft developments are reviewed. This report is intended to provide a central location for references, best practices, and lessons-learned to guide current and future spacecraft handling qualities RDT&E.

  3. Incorporating Handling Qualities Analysis into Rotorcraft Conceptual Design

    Science.gov (United States)

    Lawrence, Ben

    2014-01-01

    This paper describes the initial development of a framework to incorporate handling qualities analyses into a rotorcraft conceptual design process. In particular, the paper describes how rotorcraft conceptual design level data can be used to generate flight dynamics models for handling qualities analyses. Also, methods are described that couple a basic stability augmentation system to the rotorcraft flight dynamics model to extend analysis to beyond that of the bare airframe. A methodology for calculating the handling qualities characteristics of the flight dynamics models and for comparing the results to ADS-33E criteria is described. Preliminary results from the application of the handling qualities analysis for variations in key rotorcraft design parameters of main rotor radius, blade chord, hub stiffness and flap moment of inertia are shown. Varying relationships, with counteracting trends for different handling qualities criteria and different flight speeds are exhibited, with the action of the control system playing a complex part in the outcomes. Overall, the paper demonstrates how a broad array of technical issues across flight dynamics stability and control, simulation and modeling, control law design and handling qualities testing and evaluation had to be confronted to implement even a moderately comprehensive handling qualities analysis of relatively low fidelity models. A key outstanding issue is to how to 'close the loop' with an overall design process, and options for the exploration of how to feedback handling qualities results to a conceptual design process are proposed for future work.

  4. Evaluating the police service quality for handling traffic crash reporting

    DEFF Research Database (Denmark)

    Janstrup, Kira Hyldekær; Kaplan, Sigal; Barfod, Michael Bruhn

    2017-01-01

    at the police service quality for handling the reporting of traffic crashes. Design/methodology/approach This study introduces a novel approach to evaluate service quality that combines multi-criteria decision analysis (MCDA) with latent class analysis (LCA). Moreover, this study presents the design of a web....../value This study advances the knowledge about police service quality with a novel expert-based decision support tool based on SERVQUAL, MCDA and LCA, demonstrates its applicability in countries with a high-police service, and opportunities and barriers for increasing the crash reporting rate....... participated in the survey that yielded 86 complete responses. Findings The novel approach was successfully applied and its implementation demonstrated the usefulness of the tool even in countries with a high police service. Results showed that the participating stakeholders perceived human factors as more...

  5. Evaluating the police service quality for handling traffic crash reporting

    DEFF Research Database (Denmark)

    Janstrup, Kira Hyldekær; Kaplan, Sigal; Barfod, Michael Bruhn

    2017-01-01

    Purpose The phenomenon of traffic crash under-reporting has been extensively documented in terms of its extent, but not equally analysed in terms of its reasons. As police distrust has been recently identified as a major reason for crash under-reporting, the purpose of this paper is to look...... at the police service quality for handling the reporting of traffic crashes. Design/methodology/approach This study introduces a novel approach to evaluate service quality that combines multi-criteria decision analysis (MCDA) with latent class analysis (LCA). Moreover, this study presents the design of a web......-based survey on the basis of the SERVQUAL approach to detecting strengths, opportunities and threats with crash reporting to the police at a strategic level. Transportation stakeholders (e.g. researchers, authorities, consultants, NGO representatives, suppliers) with an interest in traffic safety in Denmark...

  6. An Investigation of Large Tilt-Rotor Hover and Low Speed Handling Qualities

    Science.gov (United States)

    Malpica, Carlos A.; Decker, William A.; Theodore, Colin R.; Lindsey, James E.; Lawrence, Ben; Blanken, Chris L.

    2011-01-01

    A piloted simulation experiment conducted on the NASA-Ames Vertical Motion Simulator evaluated the hover and low speed handling qualities of a large tilt-rotor concept, with particular emphasis on longitudinal and lateral position control. Ten experimental test pilots evaluated different combinations of Attitude Command-Attitude Hold (ACAH) and Translational Rate Command (TRC) response types, nacelle conversion actuator authority limits and inceptor choices. Pilots performed evaluations in revised versions of the ADS-33 Hover, Lateral Reposition and Depart/Abort MTEs and moderate turbulence conditions. Level 2 handling qualities ratings were primarily recorded using ACAH response type in all three of the evaluation maneuvers. The baseline TRC conferred Level 1 handling qualities in the Hover MTE, but there was a tendency to enter into a PIO associated with nacelle actuator rate limiting when employing large, aggressive control inputs. Interestingly, increasing rate limits also led to a reduction in the handling qualities ratings. This led to the identification of a nacelle rate to rotor longitudinal flapping coupling effect that induced undesired, pitching motions proportional to the allowable amount of nacelle rate. A modification that counteracted this effect significantly improved the handling qualities. Evaluation of the different response type variants showed that inclusion of TRC response could provide Level 1 handling qualities in the Lateral Reposition maneuver by reducing coupled pitch and heave off axis responses that otherwise manifest with ACAH. Finally, evaluations in the Depart/Abort maneuver showed that uncertainty about commanded nacelle position and ensuing aircraft response, when manually controlling the nacelle, demanded high levels of attention from the pilot. Additional requirements to maintain pitch attitude within 5 deg compounded the necessary workload.

  7. Evaluation of fish handling techniques employed by artisanal fishers ...

    African Journals Online (AJOL)

    Evaluation of fish handling techniques employed by artisanal fishers on quality of Lethrinids and Siganids fish genera at landing time along the Kenyan coast using sensory and microbiological methods.

  8. A pilot's assessment of helicopter handling-quality factors common to both agility and instrument flying tasks

    Science.gov (United States)

    Gerdes, R. M.

    1980-01-01

    A series of simulation and flight investigations were undertaken to evaluate helicopter flying qualities and the effects of control system augmentation for nap-of-the-Earth (NOE) agility and instrument flying tasks. Handling quality factors common to both tasks were identified. Precise attitude control was determined to be a key requirement for successful accomplishment of both tasks. Factors that degraded attitude controllability were improper levels of control sensitivity and damping, and rotor system cross coupling due to helicopter angular rate and collective pitch input. Application of rate command, attitude command, and control input decouple augmentation schemes enhanced attitude control and significantly improved handling qualities for both tasks. The NOE agility and instrument flying handling quality considerations, pilot rating philosophy, and supplemental flight evaluations are also discussed.

  9. Sheep pre-slaughter handling practices and their effect on meat quality

    Directory of Open Access Journals (Sweden)

    Francisco Gerardo Ríos-Rincón

    2013-06-01

    Full Text Available Aspects related to ovine production systems in Mexico were revisited, as well as the relationship between the transport and the ante-mortem handling with ovine welfare and pre slaughter operations. Animals stress evaluation is fundamental importance for this process, where the observation of animal behavior is basic to determinate and understands the scope of this biological phenomenon. Finally, we make reference to two of the main meat quality attributes that can be affected as consequence of non-appropriated handling practice and operations that implies the un-knowledge of animal conduct. The conclusion is that the handling practices previous to slaughter of ovine specie had a considerable influence on carcass quality. In Mexico is important to focus the cattle research on the productive systems improvement in consideration to animal welfare in the different productive process steps.

  10. Consumer evaluation of complaint handling in the Dutch health insurance market.

    Science.gov (United States)

    Wendel, Sonja; de Jong, Judith D; Curfs, Emile C

    2011-11-15

    How companies deal with complaints is a particularly challenging aspect in managing the quality of their service. In this study we test the direct and relative effects of service quality dimensions on consumer complaint satisfaction evaluations and trust in a company in the Dutch health insurance market. A cross-sectional survey design was used. Survey data of 150 members of a Dutch insurance panel who lodged a complaint at their healthcare insurer within the past 12 months were surveyed. The data were collected using a questionnaire containing validated multi-item measures. These measures assess the service quality dimensions consisting of functional quality and technical quality and consumer complaint satisfaction evaluations consisting of complaint satisfaction and overall satisfaction with the company after complaint handling. Respondents' trust in a company after complaint handling was also measured. Using factor analysis, reliability and validity of the measures were assessed. Regression analysis was used to examine the relationships between these variables. Overall, results confirm the hypothesized direct and relative effects between the service quality dimensions and consumer complaint satisfaction evaluations and trust in the company. No support was found for the effect of technical quality on overall satisfaction with the company. This outcome might be driven by the context of our study; namely, consumers get in touch with a company to resolve a specific problem and therefore might focus more on complaint satisfaction and less on overall satisfaction with the company. Overall, the model we present is valid in the context of the Dutch health insurance market. Management is able to increase consumers' complaint satisfaction, overall satisfaction with the company, and trust in the company by improving elements of functional and technical quality. Furthermore, we show that functional and technical quality do not influence consumer satisfaction evaluations and

  11. Consumer evaluation of complaint handling in the Dutch health insurance market

    Directory of Open Access Journals (Sweden)

    Wendel Sonja

    2011-11-01

    Full Text Available Abstract Background How companies deal with complaints is a particularly challenging aspect in managing the quality of their service. In this study we test the direct and relative effects of service quality dimensions on consumer complaint satisfaction evaluations and trust in a company in the Dutch health insurance market. Methods A cross-sectional survey design was used. Survey data of 150 members of a Dutch insurance panel who lodged a complaint at their healthcare insurer within the past 12 months were surveyed. The data were collected using a questionnaire containing validated multi-item measures. These measures assess the service quality dimensions consisting of functional quality and technical quality and consumer complaint satisfaction evaluations consisting of complaint satisfaction and overall satisfaction with the company after complaint handling. Respondents' trust in a company after complaint handling was also measured. Using factor analysis, reliability and validity of the measures were assessed. Regression analysis was used to examine the relationships between these variables. Results Overall, results confirm the hypothesized direct and relative effects between the service quality dimensions and consumer complaint satisfaction evaluations and trust in the company. No support was found for the effect of technical quality on overall satisfaction with the company. This outcome might be driven by the context of our study; namely, consumers get in touch with a company to resolve a specific problem and therefore might focus more on complaint satisfaction and less on overall satisfaction with the company. Conclusions Overall, the model we present is valid in the context of the Dutch health insurance market. Management is able to increase consumers' complaint satisfaction, overall satisfaction with the company, and trust in the company by improving elements of functional and technical quality. Furthermore, we show that functional and

  12. Consumer evaluation of complaint handling in the Dutch health insurance market

    Science.gov (United States)

    2011-01-01

    Background How companies deal with complaints is a particularly challenging aspect in managing the quality of their service. In this study we test the direct and relative effects of service quality dimensions on consumer complaint satisfaction evaluations and trust in a company in the Dutch health insurance market. Methods A cross-sectional survey design was used. Survey data of 150 members of a Dutch insurance panel who lodged a complaint at their healthcare insurer within the past 12 months were surveyed. The data were collected using a questionnaire containing validated multi-item measures. These measures assess the service quality dimensions consisting of functional quality and technical quality and consumer complaint satisfaction evaluations consisting of complaint satisfaction and overall satisfaction with the company after complaint handling. Respondents' trust in a company after complaint handling was also measured. Using factor analysis, reliability and validity of the measures were assessed. Regression analysis was used to examine the relationships between these variables. Results Overall, results confirm the hypothesized direct and relative effects between the service quality dimensions and consumer complaint satisfaction evaluations and trust in the company. No support was found for the effect of technical quality on overall satisfaction with the company. This outcome might be driven by the context of our study; namely, consumers get in touch with a company to resolve a specific problem and therefore might focus more on complaint satisfaction and less on overall satisfaction with the company. Conclusions Overall, the model we present is valid in the context of the Dutch health insurance market. Management is able to increase consumers' complaint satisfaction, overall satisfaction with the company, and trust in the company by improving elements of functional and technical quality. Furthermore, we show that functional and technical quality do not

  13. Orion Handling Qualities During ISS Rendezvous and Docking

    Science.gov (United States)

    Hart, Jeremy J.; Stephens, J. P.; Spehar, P.; Bilimoria, K.; Foster, C.; Gonzalex, R.; Sullivan, K.; Jackson, B.; Brazzel, J.; Hart, J.

    2011-01-01

    The Orion spacecraft was designed to rendezvous with multiple vehicles in low earth orbit (LEO) and beyond. To perform the required rendezvous and docking task, Orion must provide enough control authority to perform coarse translational maneuvers while maintaining precision to perform the delicate docking corrections. While Orion has autonomous docking capabilities, it is expected that final approach and docking operations with the International Space Station (ISS) will initially be performed in a manual mode. A series of evaluations was conducted by NASA and Lockheed Martin at the Johnson Space Center to determine the handling qualities (HQ) of the Orion spacecraft during different docking and rendezvous conditions using the Cooper-Harper scale. This paper will address the specifics of the handling qualities methodology, vehicle configuration, scenarios flown, data collection tools, and subject ratings and comments. The initial Orion HQ assessment examined Orion docking to the ISS. This scenario demonstrates the Translational Hand Controller (THC) handling qualities of Orion. During this initial assessment, two different scenarios were evaluated. The first was a nominal docking approach to a stable ISS, with Orion initializing with relative position dispersions and a closing rate of approximately 0.1 ft/sec. The second docking scenario was identical to the first, except the attitude motion of the ISS was modeled to simulate a stress case ( 1 degree deadband per axis and 0.01 deg/sec rate deadband per axis). For both scenarios, subjects started each run on final approach at a docking port-to-port range of 20 ft. Subjects used the THC in pulse mode with cues from the docking camera image, window views, and range and range rate data displayed on the Orion display units. As in the actual design, the attitude of the Orion vehicle was held by the automated flight control system at 0.5 degree deadband per axis. Several error sources were modeled including Reaction

  14. A pilot modeling technique for handling-qualities research

    Science.gov (United States)

    Hess, R. A.

    1980-01-01

    A brief survey of the more dominant analysis techniques used in closed-loop handling-qualities research is presented. These techniques are shown to rely on so-called classical and modern analytical models of the human pilot which have their foundation in the analysis and design principles of feedback control. The optimal control model of the human pilot is discussed in some detail and a novel approach to the a priori selection of pertinent model parameters is discussed. Frequency domain and tracking performance data from 10 pilot-in-the-loop simulation experiments involving 3 different tasks are used to demonstrate the parameter selection technique. Finally, the utility of this modeling approach in handling-qualities research is discussed.

  15. Aircraft model prototypes which have specified handling-quality time histories

    Science.gov (United States)

    Johnson, S. H.

    1978-01-01

    Several techniques for obtaining linear constant-coefficient airplane models from specified handling-quality time histories are discussed. The pseudodata method solves the basic problem, yields specified eigenvalues, and accommodates state-variable transfer-function zero suppression. The algebraic equations to be solved are bilinear, at worst. The disadvantages are reduced generality and no assurance that the resulting model will be airplane like in detail. The method is fully illustrated for a fourth-order stability-axis small motion model with three lateral handling quality time histories specified. The FORTRAN program which obtains and verifies the model is included and fully documented.

  16. Evaluation of 100 brain examinations using a 3 Tesla MR-compatible incubator - safety, handling, and image quality

    International Nuclear Information System (INIS)

    Sirin, Selma; Goericke, Sophia L.; Kinner, Sonja; Schweiger, Bernd; Huening, Britta M.; Stein, Anja; Felderhoff-Mueser, Ursula

    2013-01-01

    Several studies have revealed the importance of brain imaging in term and preterm infants. The aim of this retrospective study was to review safety, handling, and image quality of MR brain imaging using a new 3 Tesla MR-compatible incubator. Between 02/2011 and 05/2012 100 brain MRIs (84 infants, mean gestational age 32.2 ± 4.7 weeks, mean postmenstrual age at imaging 40.6 ± 3.4 weeks) were performed using a 3 Tesla MR-compatible incubator with dedicated, compatible head coil. Seventeen examinations (13 infants, mean gestational age 35.1 ± 5.4 weeks, mean postmenstrual age at imaging 47.8 ± 7.4 weeks) with a standard head coil served as a control. Image analysis was performed by a neuroradiologist and a pediatric radiologist in consensus. All but two patients with known apnea were transferred to the MR unit and scanned without problems. Handling was easier and faster with the incubator; relevant motion artifacts (5.9 vs. 10.8 %) and the need for repetitive sedation (43.0 vs. 86.7 %) were reduced. Considering only images not impaired by motion artifacts, image quality (4.8 ± 0.4 vs. 4.3 ± 0.8, p = 0.047) and spatial resolution (4.7 ± 0.4 vs. 4.2 ± 0.6, p = 0.011) of T2-weighted images were scored significantly higher in patients imaged with the incubator. SNR increased significantly (171.6 ± 54.5 vs. 80.5 ± 19.8, p < 0.001) with the use of the incubator. Infants can benefit from the use of a 3 Tesla MR-compatible incubator because of its safety, easier, and faster handling (compared to standard imaging) and possibility to obtain high-quality MR images even in unstable patients. (orig.)

  17. Microphone Handling Noise: Measurements of Perceptual Threshold and Effects on Audio Quality.

    Directory of Open Access Journals (Sweden)

    Paul Kendrick

    Full Text Available A psychoacoustic experiment was carried out to test the effects of microphone handling noise on perceived audio quality. Handling noise is a problem affecting both amateurs using their smartphones and cameras, as well as professionals using separate microphones and digital recorders. The noises used for the tests were measured from a variety of devices, including smartphones, laptops and handheld microphones. The signal features that characterise these noises are analysed and presented. The sounds include various types of transient, impact noises created by tapping or knocking devices, as well as more sustained sounds caused by rubbing. During the perceptual tests, listeners auditioned speech podcasts and were asked to rate the degradation of any unwanted sounds they heard. A representative design test methodology was developed that tried to encourage everyday rather than analytical listening. Signal-to-noise ratio (SNR of the handling noise events was shown to be the best predictor of quality degradation. Other factors such as noise type or background noise in the listening environment did not significantly affect quality ratings. Podcast, microphone type and reproduction equipment were found to be significant but only to a small extent. A model allowing the prediction of degradation from the SNR is presented. The SNR threshold at which 50% of subjects noticed handling noise was found to be 4.2 ± 0.6 dBA. The results from this work are important for the understanding of our perception of impact sound and resonant noises in recordings, and will inform the future development of an automated predictor of quality for handling noise.

  18. A Cybernetic Approach to Assess the Longitudinal Handling Qualities of Aeroelastic Aircraft

    NARCIS (Netherlands)

    Damveld, H.J.

    2009-01-01

    The future demand for larger and lighter civil transport aircraft leads to more flexible aircraft, which bring their own controlling and handling problems. A review of established handling qualities methods showed that they were either unsuitable for aeroelastic aircraft, or had significant

  19. Plutonium stabilization and handling quality assurance program plan

    International Nuclear Information System (INIS)

    Weiss, E.V.

    1998-01-01

    This Quality Assurance Program Plan (QAPP) identifies project quality assurance requirements for all contractors involved in the planning and execution of Hanford Site activities for design, procurement, construction, testing and inspection for Project W-460, Plutonium Stabilization and Handling. The project encompasses procurement and installation of a Stabilization and Packaging System (SPS) to oxidize and package for long term storage remaining plutonium-bearing special nuclear materials currently in inventory at the Plutonium Finishing Plant (PFP), and modification of vault equipment to allow storage of resulting packages of stabilized SNM

  20. A modal analysis of flexible aircraft dynamics with handling qualities implications

    Science.gov (United States)

    Schmidt, D. K.

    1983-01-01

    A multivariable modal analysis technique is presented for evaluating flexible aircraft dynamics, focusing on meaningful vehicle responses to pilot inputs and atmospheric turbulence. Although modal analysis is the tool, vehicle time response is emphasized, and the analysis is performed on the linear, time-domain vehicle model. In evaluating previously obtained experimental pitch tracking data for a family of vehicle dynamic models, it is shown that flexible aeroelastic effects can significantly affect pitch attitude handling qualities. Consideration of the eigenvalues alone, of both rigid-body and aeroelastic modes, does not explain the simulation results. Modal analysis revealed, however, that although the lowest aeroelastic mode frequency was still three times greater than the short-period frequency, the rigid-body attitude response was dominated by this aeroelastic mode. This dominance was defined in terms of the relative magnitudes of the modal residues in selected vehicle responses.

  1. Catch Index : Development of a tool for measurement the quality of the catch handling at sea

    NARCIS (Netherlands)

    Schelvis-Smit, A.A.M.; Luten, J.B.

    2003-01-01

    Correct fish handling on board of vessels is essential for the quality of the fish throughout the complete fishery chain. Developments in the fishery sector with respect to quality control, traceability and remote trade demand a tool to access the performance of fish handling by fishermen. Therefore

  2. Efficient halal bleeding, animal handling, and welfare: A holistic approach for meat quality.

    Science.gov (United States)

    Aghwan, Z A; Bello, A U; Abubakar, A A; Imlan, J C; Sazili, A Q

    2016-11-01

    Traditional halal slaughter and other forms of religious slaughter are still an issue of debate. Opposing arguments related to pre-slaughter handling, stress and pain associated with restraint, whether the incision is painful or not, and the onset of unconsciousness have been put forward, but no consensus has been achieved. There is a need to strike a balance between halal bleeding in the light of science and animal welfare. There is a paucity of scientific data with respect to animal welfare, particularly the use of restraining devices, animal handling, and efficient halal bleeding. However, this review found that competent handling of animals, proper use of restraining devices, and the efficient bleeding process that follows halal slaughter maintains meat eating quality. In conclusion, halal bleeding, when carried out in accordance with recommended animal welfare procedures, will not only maintain the quality and wholesomeness of meat but could also potentially reduce suffering and pain. Maintained meat quality increases consumer satisfaction and food safety. Copyright © 2016. Published by Elsevier Ltd.

  3. Evaluation of hygiene practices and microbiological quality of cooked meat products during slicing and handling at retail.

    Science.gov (United States)

    Pérez-Rodríguez, F; Castro, R; Posada-Izquierdo, G D; Valero, A; Carrasco, E; García-Gimeno, R M; Zurera, G

    2010-10-01

    Cooked meat ready-to-eat products are recognized to be contaminated during slicing which, in the last years, has been associated with several outbreaks. This work aimed to find out possible relation between the hygiene practice taking place at retail point during slicing of cooked meat products in small and medium-sized establishments (SMEs) and large-sized establishments (LEs) and the microbiological quality of sliced cooked meat products. For that, a checklist was drawn up and filled in based on scoring handling practice during slicing in different establishments in Cordoba (Southern Spain). In addition, sliced cooked meats were analyzed for different microbiological indicators and investigated for the presence of Listeria spp. and Listeria monocytogenes. Results indicated that SMEs showed a more deficient handling practices compared to LEs. In spite of these differences, microbiological counts indicated similar microbiological quality in cooked meat samples for both types of establishments. On the other hand, Listeria monocytogenes and Listeria inocua were isolated from 7.35% (5/68) and 8.82% (6/68) of analyzed samples, respectively. Positive samples for Listeria spp. were found in establishments which showed acceptable hygiene levels, though contamination could be associated to the lack of exclusiveness of slicers at retail points. Moreover, Listeria spp presence could not be statistically linked to any microbiological parameters; however, it was observed that seasonality influenced significantly (Phygiene practices, focused specially on SMEs. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  4. Ergonomic design and evaluation of the handle for an endoscopic dissector.

    Science.gov (United States)

    Shimomura, Yoshihiro; Minowa, Keita; Kawahira, Hiroshi; Katsuura, Tetsuo

    2016-05-01

    The purpose of this study was to design an endoscopic dissector handle and objectively assess its usability. The handles were designed with increased contact area between the fingers and thumb and the eye rings, and the eye rings were modified to have a more perpendicular insertion angle to the finger midline. Four different handle models were compared, including a conventional product. Subjects performed dissection, exclusion, grasping, precision manipulation and precision handling tasks. Electromyography and subjective evaluations were measured. Compared to conventional handles, the designated handle reduced the muscle load in the extensor and flexor muscles of the forearm and increased subjective stability. The activity of the first dorsal interosseous muscle was sometimes influenced by the shape of the other parts. The ergonomically designed endoscopic dissector handle used in this study achieved high usability. Medical instrument designs based on ergonomic concepts should be assessed with objective indices. Practitioner Summary: The endoscopic dissector handles were designed with increased contact area and more suitable insertion angle between the fingers and thumb and the eye rings. Compared to conventional handles, the designated handle reduced the muscle load in the extensor and flexor muscles of the forearm and increased subjective stability.

  5. Development and perceived effects of an educational programme on quality and safety in medication handling in residential facilities.

    Science.gov (United States)

    Mygind, Anna; El-Souri, Mira; Rossing, Charlotte; Thomsen, Linda Aagaard

    2018-04-01

    To develop and test an educational programme on quality and safety in medication handling for staff in residential facilities for the disabled. The continuing pharmacy education instructional design model was used to develop the programme with 22 learning objectives on disease and medicines, quality and safety, communication and coordination. The programme was a flexible, modular seven + two days' course addressing quality and safety in medication handling, disease and medicines, and medication supervision and reconciliation. The programme was tested in five Danish municipalities. Municipalities were selected based on their application for participation; each independently selected a facility for residents with mental and intellectual disabilities, and a facility for residents with severe mental illnesses. Perceived effects were measured based on a questionnaire completed by participants before and after the programme. Effects on motivation and confidence as well as perceived effects on knowledge, skills and competences related to medication handling, patient empowerment, communication, role clarification and safety culture were analysed conducting bivariate, stratified analyses and test for independence. Of the 114 participants completing the programme, 75 participants returned both questionnaires (response rate = 66%). Motivation and confidence regarding quality and safety in medication handling significantly improved, as did perceived knowledge, skills and competences on 20 learning objectives on role clarification, safety culture, medication handling, patient empowerment and communication. The programme improved staffs' motivation and confidence and their perceived ability to handle residents' medication safely through improved role clarification, safety culture, medication handling and patient empowerment and communication skills. © 2017 Royal Pharmaceutical Society.

  6. Prediction of the handling qualities and pilot-induced oscillation rating levels

    Directory of Open Access Journals (Sweden)

    Andreea-Irina AFLOARE

    2014-04-01

    Full Text Available The basis for the aviation development is the ambition of increasing the efficiency and safety of flight. Improvements include flight performance and extended flight envelope, new flight regimes and tasks. However, all of these factors lead to the increase of pilot workload which can reduce the accuracy and safety of flight. Fixed and rotary wing pilots are being confronted with potential instabilities or with annoying limit cycle oscillations, known as Aircraft/Rotorcraft Pilot Couplings (A/RPC that arise from the effort of controlling the vehicle with high response actuators. This paper deals with the unified theory of predicting handling qualities level (HQSF and pilot-induced oscillation rating levels (PIOR based on the structural model of human operator, developed by Hess. HQSF and PIOR are capable of capturing the prominent features of human pilot dynamics characteristics for a large class of aerial vehicles and tasks. The key element in this method is to unify the topics of vehicle handling qualities and RPC/PIO, applied to the analysis of a medium weight helicopter model.

  7. Evaluation of design and operation of fuel handling systems for 25 MW biomass fueled CFB power plants

    International Nuclear Information System (INIS)

    Precht, D.

    1991-01-01

    Two circulating fluidized bed, biomass fueled, 25MW power plants were placed into operation by Thermo Electron Energy Systems in California during late 1989. This paper discusses the initial fuel and system considerations, system design, actual operating fuel characterisitics, system operation during the first year and modifications. Biomass fuels handled by the system include urban/manufacturing wood wastes and agricultural wastes in the form of orchard prunings, vineyard prunings, pits, shells, rice hulls and straws. Equipment utilized in the fuel handling system are described and costs are evaluated. Lessons learned from the design and operational experience are offered for consideration on future biomass fueled installations where definition of fuel quality and type is subject to change

  8. TITLE III EVALUATION REPORT FOR THE MATERIAL AND PERSONNEL HANDLING SYSTEM

    International Nuclear Information System (INIS)

    T. A. Misiak

    1998-01-01

    This Title III Evaluation Report (TER) provides the results of an evaluation that was conducted on the Material and Personnel Handling System. This TER has been written in accordance with the ''Technical Document Preparation Plan for the Mined Geologic Disposal System Title III Evaluation Reports'' (BA0000000-01717-4600-00005 REV 03). The objective of this evaluation is to provide recommendations to ensure consistency between the technical baseline requirements, baseline design, and the as-constructed Material and Personnel Handling System. Recommendations for resolving discrepancies between the as-constructed system, the technical baseline requirements, and the baseline design are included in this report. Cost and Schedule estimates are provided for all recommended modifications

  9. Performance Evaluation and Suggestion of Upgraded Fuel Handling Equipment for Operating OPR1000

    International Nuclear Information System (INIS)

    Chang, Sang Gyoon; Hwang, Jeung Ki; Choi, Taek Sang; Na, Eun Seok; Lee, Myung Lyul; Baek, Seung Jin; Kim, Man Su; Kunik, Jack

    2011-01-01

    The purpose of this study is to evaluate the performance of upgraded FHE (Fuel Handling Equipment) for operating OPR 1000 (Optimized Power Reactor) by using data measured during the fuel reloading, and make some suggestions on enhancing the performance of the FHE. The fuel handling equipment, which serves critical processes in the refueling outage, has been upgraded to increase and improve the operational availability of the plant. The evaluation and suggestion of this study can be a beneficial tool related to the performance of the fuel handling equipment

  10. Analysis of Handling Qualities Design Criteria for Active Inceptor Force-Feel Characteristics

    Science.gov (United States)

    Malpica, Carlos A.; Lusardi, Jeff A.

    2013-01-01

    ratio. While these two studies produced boundaries for acceptable/unacceptable stick dynamics for rotorcraft, they were not able to provide guidance on how variations of the stick dynamics in the acceptable region impact handling qualities. More recently, a ground based simulation study [5] suggested little benefit was to be obtained from variations of the damping ratio for a side-stick controller exhibiting high natural frequencies (greater than 17 rad/s) and damping ratios (greater than 2.0). A flight test campaign was conducted concurrently on the RASCAL JUH-60A in-flight simulator and the ACT/FHS EC-135 in flight simulator [6]. Upon detailed analysis of the pilot evaluations the study identified a clear preference for a high damping ratio and natural frequency of the center stick inceptors. Side stick controllers were found to be less sensitive to the damping. While these studies have compiled a substantial amount of data, in the form of qualitative and quantitative pilot opinion, a fundamental analysis of the effect of the inceptor force-feel system on flight control is found to be lacking. The study of Ref. [6] specifically concluded that a systematic analysis was necessary, since discrepancies with the assigned handling qualities showed that proposed analytical design metrics, or criteria, were not suitable. The overall goal of the present study is to develop a clearer fundamental understanding of the underlying mechanisms associated with the inceptor dynamics that govern the handling qualities using a manageable analytical methodology.

  11. Profiles of the evaluators: impact of psychographic variables on the consumer-oriented quality assessment of mobile television

    Science.gov (United States)

    Jumisko-Pyykkö, Satu; Häkkinen, Jukka

    2008-02-01

    In the product development of services it is important to adjust mobile video quality according to the quality requirements of potential users. Therefore, a careful participant selection is very important. However, in the literature the details of participant selection are often handled without great detail. This is also reflected in the handling of experimental results, where the impact of psychographic factors on quality is rarely reported. As the user attributes potentially have a large effect to the results, we investigated the role of various psychographical variables on the subjective evaluation of audiovisual video quality in two different experiments. The studied variables were age, gender, education, professionalism, television consumption, experiences of different digital video qualities, and attitude towards technology. The results showed that quality evaluations were affected by almost all background factors. The most significant variables were age, professionalism, knowledge of digital quality features and attitude towards technology. The knowledge of these factors can be exploited in careful participant selection, which will in turn increase the validity of results as the subjective evaluations reflect better the requirements of potential users.

  12. Evaluating the Open Source Data Containers for Handling Big Geospatial Raster Data

    Directory of Open Access Journals (Sweden)

    Fei Hu

    2018-04-01

    Full Text Available Big geospatial raster data pose a grand challenge to data management technologies for effective big data query and processing. To address these challenges, various big data container solutions have been developed or enhanced to facilitate data storage, retrieval, and analysis. Data containers were also developed or enhanced to handle geospatial data. For example, Rasdaman was developed to handle raster data and GeoSpark/SpatialHadoop were enhanced from Spark/Hadoop to handle vector data. However, there are few studies to systematically compare and evaluate the features and performances of these popular data containers. This paper provides a comprehensive evaluation of six popular data containers (i.e., Rasdaman, SciDB, Spark, ClimateSpark, Hive, and MongoDB for handling multi-dimensional, array-based geospatial raster datasets. Their architectures, technologies, capabilities, and performance are compared and evaluated from two perspectives: (a system design and architecture (distributed architecture, logical data model, physical data model, and data operations; and (b practical use experience and performance (data preprocessing, data uploading, query speed, and resource consumption. Four major conclusions are offered: (1 no data containers, except ClimateSpark, have good support for the HDF data format used in this paper, requiring time- and resource-consuming data preprocessing to load data; (2 SciDB, Rasdaman, and MongoDB handle small/mediate volumes of data query well, whereas Spark and ClimateSpark can handle large volumes of data with stable resource consumption; (3 SciDB and Rasdaman provide mature array-based data operation and analytical functions, while the others lack these functions for users; and (4 SciDB, Spark, and Hive have better support of user defined functions (UDFs to extend the system capability.

  13. Evaluation of Four Bedside Test Systems for Card Performance, Handling and Safety.

    Science.gov (United States)

    Giebel, Felix; Picker, Susanne M; Gathof, Birgit S

    2008-01-01

    SUMMARY: OBJECTIVE: Pretransfusion ABO compatibility testing is a simple and required precaution against ABO-incompatible transfusion, which is one of the greatest threats in transfusion medicine. While distinct agglutination is most important for correct test interpretation, protection against infectious diseases and ease of handling are crucial for accurate test performance. Therefore, the aim of this study was to evaluate differences in test card design, handling, and user safety. DESIGN: Four different bedside test cards with pre-applied antibodies were evaluated by 100 medical students using packed red blood cells of different ABO blood groups. Criteria of evaluation were: agglutination, labelling, handling, and safety regarding possible user injuries. Criteria were rated subjectively according to German school notes ranging from 1 = very good to 6 = very bad/insufficient. RESULTS: Overall, all cards received very good/good marks. The ABO blood group was identified correctly in all cases. Three cards (no. 1, no. 3, no. 4) received statistically significant (p labelling (1.5 vs. 2.2-2.4), handling (1.9-2.0 vs. 2.5), and user safety (2.5 vs. 3.4). Analysis of card self-explanation revealed no remarkable differences. CONCLUSION: Despite good performance of all card systems tested, the best results when including all criteria evaluated were obtained with card no. 4 (particularly concerning clear agglutination), followed by cards no. 2, no. 1, and no. 3.

  14. Evaluation of ergonomic risk factors in manual patient handling ...

    African Journals Online (AJOL)

    WMSDs among nurses in West Bengal, India, evaluates the postural stresses and analyses manual patient handling risks. Responses were collected from 220 nurses by validated questionnaires. The activity and posture analyses were done through photography and by Rapid Entire Body Assessment (REBA). Results ...

  15. Ergonomics and comfort in lawn mower handle positioning: An evaluation of handle geometry.

    Science.gov (United States)

    Lowndes, Bethany R; Heald, Elizabeth A; Hallbeck, M Susan

    2015-11-01

    Hand operation accompanied with any combination of large forces, awkward positions and repetition may lead to upper limb injury or illness and may be exacerbated by vibration. Commercial lawn mowers expose operators to these factors during actuation of hand controls and therefore may be a health concern. A nontraditional lawn mower control system may decrease upper limb illnesses and injuries through more neutral hand and body positioning. This study compared maximum grip strength in twelve different orientations (3 grip spans and 4 positions) and evaluated self-described comfortable handle positions. The results displayed force differences between nontraditional (X) and both vertical (V) and pistol (P) positions (p < 0.0001) and among the different grip spans (p < 0.0001). Based on these results, recommended designs should incorporate a tilt between 45 and 70°, handle rotations between 48 and 78°, and reduced force requirements or decreased grip spans to improve user health and comfort. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  16. Waste Handling Equipment Development Test and Evaluation Study

    International Nuclear Information System (INIS)

    R.L. Tome

    1998-01-01

    The purpose of this study is to identify candidate Monitored Geologic Repository (MGR) surface waste handling equipment for development testing. This study will also identify strategies for performing the development tests. Development testing shall be implemented to support detail design and reduce design risks. Development testing shall be conducted to confirm design concepts, evaluate alternative design concepts, show the availability of needed technology, and provide design documentation. The candidate equipment will be selected from MGR surface waste handling equipment that is the responsibility of the Management and Operating Contractor (M and O) Surface Design Department. The equipment identified in this study is based on Viability Assessment (VA) design. The ''Monitored Geologic Repository Test and Evaluation Plan'' (MGR T and EP), Reference 5.1, was used as a basis for this study. The MGR T and EP reflects the extent of test planning and analysis that can be conducted, given the current status of the MGR requirements and latest VA design information. The MGR T and EP supports the appropriate sections in the license application (LA) in accordance with 10 CFR 60.2 1(c)(14). The MGR T and EP describes the following test activities: site characterization to confirm, by test and analysis, the suitability of the Yucca Mountain site for housing a geologic repository; development testing to investigate and document design concepts to reduce risk; qualification testing to verify equipment compliance with design requirements, specifications, and regulatory requirements; system testing to validate compliance with MGR requirements, which include the receipt, handling, retrieval, and disposal of waste; periodic performance testing to verify preclosure requirements and to demonstrate safe and reliable MGR operation; and performance confirmation modeling, testing, and analysis to verify adherence to postclosure regulatory requirements. Development test activities can be

  17. A simulation-based approach for evaluating logging residue handling systems.

    Science.gov (United States)

    B. Bruce Bare; Benjamin A. Jayne; Brian F. Anholt

    1976-01-01

    Describes a computer simulation model for evaluating logging residue handling systems. The flow of resources is traced through a prespecified combination of operations including yarding, chipping, sorting, loading, transporting, and unloading. The model was used to evaluate the feasibility of converting logging residues to chips that could be used, for example, to...

  18. Development and evaluation of online video teaching resources to enhance student knowledge of livestock handling.

    Science.gov (United States)

    Klupiec, C; Pope, S; Taylor, R; Carroll, D; Ward, M H; Celi, P

    2014-07-01

    To evaluate the effectiveness of online audiovisual materials to support the acquisition of animal handling skills by students of veterinary and animal science. A series of video clips (Livestock Handling modules) demonstrating livestock handling procedures was created and delivered online to students enrolled in the Faculty of Veterinary Science, University of Sydney. The effectiveness of these modules for supporting student learning was evaluated via an online survey. The survey also sought feedback on how students could be better prepared for handling livestock. The survey indicated that students found the videos a useful part of their learning experience, particularly by familiarising them with correct handling procedures and emphasising the importance of safety when handling livestock. Students also highlighted that online delivery supported flexible learning. Suggested improvements of the Livestock Handling modules centred around broadening the content of the videos and improving the user-friendliness of online access. Student feedback regarding how the Faculty could better prepare them for livestock handling was dominated by requests for more opportunities to practise animal handling using live animals. The Livestock Handling audiovisual tool is a valuable supplementary resource for developing students' proficiency in safe and effective handling of livestock. However, the results also clearly reveal a perception by students that more hands-on experience is required for acquisition of animal handling skills. These findings will inform future development of the Faculty's animal handling program. © 2014 Australian Veterinary Association.

  19. Handling of multiassembly sealed baskets between reactor storage and a remote handling facility

    International Nuclear Information System (INIS)

    Massey, J.V.; Kessler, J.H.; McSherry, A.J.

    1989-06-01

    The storage of multiple fuel assemblies in sealed (welded) dry storage baskets is gaining increasing use to augment at-reactor fuel storage capacity. Since this increasing use will place a significant number of such baskets on reactor sites, some initial downstream planning for their future handling scenarios for retrieving multi-assembly sealed baskets (MSBs) from onsite storage and transferring and shipping the fuel (and/or the baskets) to a federally operated remote handling facility (RHF). Numerous options or at-reactor and away-from-reactor handling were investigated. Materials handling flowsheets were developed along with conceptual designs for the equipment and tools required to handle and open the MSBs. The handling options were evaluated and compared to a reference case, fuel handling sequence (i.e., fuel assemblies are taken from the fuel pool, shipped to a receiving and handling facility and placed into interim storage). The main parameters analyzed are throughout, radiation dose burden and cost. In addition to evaluating the handling of MSBs, this work also evaluated handling consolidated fuel canisters (CFCs). In summary, the handling of MSBs and CFCs in the store, ship and bury fuel cycle was found to be feasible and, under some conditions, to offer significant benefits in terms of throughput, cost and safety. 14 refs., 20 figs., 24 tabs

  20. Microbiological quality and safe handling of enteral diets in a hospital in Minas Gerais, Brazil.

    Science.gov (United States)

    Pinto, Raquel Oliveira Medrado; Correia, Eliznara Fernades; Pereira, Keyla Carvalho; Costa Sobrinho, Paulo de Souza; da Silva, Daniele Ferreira

    2015-06-01

    Contamination of enteral diets represents a high risk of compromising the patient's medical condition. To assess the microbiological quality and aseptic conditions in the preparation and administration of handmade and industrialized enteral diets offered in a hospital in the Valley of Jequitinhonha, MG, Brazil, we performed a microbiological analysis of 50 samples of diets and 27 samples of surfaces, utensils, and water used in the preparation of the diets. In addition, we assessed the good handling practices of enteral diets according to the requirements specified by the Brazilian legislation. Both kinds of enteral diets showed contamination by coliforms and Pseudomonas spp. No sample was positive for Staphylococcus aureus and Salmonella spp. On the other hand, Listeria spp. was detected in only one sample of handmade diets. Contamination was significantly higher in the handmade preparations (p Nonconformities were detected with respect to good handling practices, which may compromise the diet safety. The results indicate that the sanitary quality of the enteral diets is unsatisfactory, especially handmade diets. Contamination by Pseudomonas spp. is significant because it is often involved in infection episodes. With regard to aseptic practices, it was observed the need of implementing new procedures for handling enteral diets.

  1. Process service quality evaluation based on Dempster-Shafer theory and support vector machine.

    Science.gov (United States)

    Pei, Feng-Que; Li, Dong-Bo; Tong, Yi-Fei; He, Fei

    2017-01-01

    Human involvement influences traditional service quality evaluations, which triggers an evaluation's low accuracy, poor reliability and less impressive predictability. This paper proposes a method by employing a support vector machine (SVM) and Dempster-Shafer evidence theory to evaluate the service quality of a production process by handling a high number of input features with a low sampling data set, which is called SVMs-DS. Features that can affect production quality are extracted by a large number of sensors. Preprocessing steps such as feature simplification and normalization are reduced. Based on three individual SVM models, the basic probability assignments (BPAs) are constructed, which can help the evaluation in a qualitative and quantitative way. The process service quality evaluation results are validated by the Dempster rules; the decision threshold to resolve conflicting results is generated from three SVM models. A case study is presented to demonstrate the effectiveness of the SVMs-DS method.

  2. 77 FR 58416 - Comparative Environmental Evaluation of Alternatives for Handling Low-Level Radioactive Waste...

    Science.gov (United States)

    2012-09-20

    ... for Handling Low-Level Radioactive Waste Spent Ion Exchange Resins From Commercial Nuclear Power... Radioactive Waste Spent Ion Exchange Resins from Commercial Nuclear Power Reactors. DATES: Please submit... Evaluation of Alternatives for Handling Low-Level Radioactive Waste Spent Ion Exchange Resins from Commercial...

  3. 30o inclination in handles of plastic boxes can reduce postural and muscular workload during handling

    Directory of Open Access Journals (Sweden)

    Luciana C. C. B. Silva

    2013-06-01

    Full Text Available BACKGROUND: The handling of materials, which occurs in the industrial sector, is associated with lesions on the lumbar spine and in the upper limbs. Inserting handles in industrial boxes is a way to reduce work-related risks. Although the position and angle of the handles are significant factors in comfort and safety during handling, these factors have rarely been studied objectively. OBJECTIVE: To compare the handling of a commercial box and prototypes with handles and to evaluate the effects on upper limb posture, muscle electrical activity, and perceived acceptability using different grips while handling materials from different heights. METHOD: Thirty-seven healthy volunteers evaluated the handles of prototypes that allowed for changes in position (top and bottom and angle (0°, 15°, and 30°. Wrist, elbow, and shoulder movements were evaluated using electrogoniometry and inclinometry. The muscle electrical activity in the wrist extensors, biceps brachii, and the upper portion of the trapezius was measured using a portable electromyographer. The recorded data on muscle movements and electrical activity were synchronized. Subjective evaluations of acceptability were evaluated using a visual analog scale. RESULTS AND CONCLUSIONS: The prototypes with handles at a 30° angle produced the highest acceptability ratings, more neutral wrist positions, lower levels of electromyographic activity for the upper trapezius, and lower elevation angles for the arms. The different measurement methods were complementary in evaluating the upper limbs during handling.

  4. HOPE: An On-Line Piloted Handling Qualities Experiment Data Book

    Science.gov (United States)

    Jackson, E. B.; Proffitt, Melissa S.

    2010-01-01

    A novel on-line database for capturing most of the information obtained during piloted handling qualities experiments (either flight or simulated) is described. The Hyperlinked Overview of Piloted Evaluations (HOPE) web application is based on an open-source object-oriented Web-based front end (Ruby-on-Rails) that can be used with a variety of back-end relational database engines. The hyperlinked, on-line data book approach allows an easily-traversed way of looking at a variety of collected data, including pilot ratings, pilot information, vehicle and configuration characteristics, test maneuvers, and individual flight test cards and repeat runs. It allows for on-line retrieval of pilot comments, both audio and transcribed, as well as time history data retrieval and video playback. Pilot questionnaires are recorded as are pilot biographies. Simple statistics are calculated for each selected group of pilot ratings, allowing multiple ways to aggregate the data set (by pilot, by task, or by vehicle configuration, for example). Any number of per-run or per-task metrics can be captured in the database. The entire run metrics dataset can be downloaded in comma-separated text for further analysis off-line. It is expected that this tool will be made available upon request

  5. Process service quality evaluation based on Dempster-Shafer theory and support vector machine.

    Directory of Open Access Journals (Sweden)

    Feng-Que Pei

    Full Text Available Human involvement influences traditional service quality evaluations, which triggers an evaluation's low accuracy, poor reliability and less impressive predictability. This paper proposes a method by employing a support vector machine (SVM and Dempster-Shafer evidence theory to evaluate the service quality of a production process by handling a high number of input features with a low sampling data set, which is called SVMs-DS. Features that can affect production quality are extracted by a large number of sensors. Preprocessing steps such as feature simplification and normalization are reduced. Based on three individual SVM models, the basic probability assignments (BPAs are constructed, which can help the evaluation in a qualitative and quantitative way. The process service quality evaluation results are validated by the Dempster rules; the decision threshold to resolve conflicting results is generated from three SVM models. A case study is presented to demonstrate the effectiveness of the SVMs-DS method.

  6. Microbiological quality and safe handling of enteral diets in a hospital in Minas Gerais, Brazil

    Directory of Open Access Journals (Sweden)

    Raquel Oliveira Medrado Pinto

    2015-06-01

    Full Text Available Contamination of enteral diets represents a high risk of compromising the patient's medical condition. To assess the microbiological quality and aseptic conditions in the preparation and administration of handmade and industrialized enteral diets offered in a hospital in the Valley of Jequitinhonha, MG, Brazil, we performed a microbiological analysis of 50 samples of diets and 27 samples of surfaces, utensils, and water used in the preparation of the diets. In addition, we assessed the good handling practices of enteral diets according to the requirements specified by the Brazilian legislation. Both kinds of enteral diets showed contamination by coliforms and Pseudomonas spp. No sample was positive for Staphylococcus aureus and Salmonella spp. On the other hand, Listeria spp. was detected in only one sample of handmade diets. Contamination was significantly higher in the handmade preparations (p < 0.05. Nonconformities were detected with respect to good handling practices, which may compromise the diet safety. The results indicate that the sanitary quality of the enteral diets is unsatisfactory, especially handmade diets. Contamination by Pseudomonas spp. is significant because it is often involved in infection episodes. With regard to aseptic practices, it was observed the need of implementing new procedures for handling enteral diets.

  7. Development of the remote-handled transuranic waste radioassay data quality objectives. An evaluation of RH-TRU waste inventories, characteristics, radioassay methods and capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Meeks, A.M.; Chapman, J.A.

    1997-09-01

    The Waste Isolation Pilot Plant will accept remote-handled transuranic waste as early as October of 2001. Several tasks must be accomplished to meet this schedule, one of which is the development of Data Quality Objectives (DQOs) and corresponding Quality Assurance Objectives (QAOs) for the assay of radioisotopes in RH-TRU waste. Oak Ridge National Laboratory (ORNL) was assigned the task of providing to the DOE QAO, information necessary to aide in the development of DQOs for the radioassay of RH-TRU waste. Consistent with the DQO process, information needed and presented in this report includes: identification of RH-TRU generator site radionuclide data that may have potential significance to the performance of the WIPP repository or transportation requirements; evaluation of existing methods to measure the identified isotopic and quantitative radionuclide data; evaluation of existing data as a function of site waste streams using documented site information on fuel burnup, radioisotope processing and reprocessing, special research and development activities, measurement collection efforts, and acceptable knowledge; and the current status of technologies and capabilities at site facilities for the identification and assay of radionuclides in RH-TRU waste streams. This report is intended to provide guidance in developing the RH-TRU waste radioassay DQOs, first by establishing a baseline from which to work, second, by identifying needs to fill in the gaps between what is known and achievable today and that which will be required before DQOs can be formulated, and third, by recommending measures that should be taken to assure that the DQOs in fact balance risk and cost with an achievable degree of certainty.

  8. Development of the remote-handled transuranic waste radioassay data quality objectives. An evaluation of RH-TRU waste inventories, characteristics, radioassay methods and capabilities

    International Nuclear Information System (INIS)

    Meeks, A.M.; Chapman, J.A.

    1997-09-01

    The Waste Isolation Pilot Plant will accept remote-handled transuranic waste as early as October of 2001. Several tasks must be accomplished to meet this schedule, one of which is the development of Data Quality Objectives (DQOs) and corresponding Quality Assurance Objectives (QAOs) for the assay of radioisotopes in RH-TRU waste. Oak Ridge National Laboratory (ORNL) was assigned the task of providing to the DOE QAO, information necessary to aide in the development of DQOs for the radioassay of RH-TRU waste. Consistent with the DQO process, information needed and presented in this report includes: identification of RH-TRU generator site radionuclide data that may have potential significance to the performance of the WIPP repository or transportation requirements; evaluation of existing methods to measure the identified isotopic and quantitative radionuclide data; evaluation of existing data as a function of site waste streams using documented site information on fuel burnup, radioisotope processing and reprocessing, special research and development activities, measurement collection efforts, and acceptable knowledge; and the current status of technologies and capabilities at site facilities for the identification and assay of radionuclides in RH-TRU waste streams. This report is intended to provide guidance in developing the RH-TRU waste radioassay DQOs, first by establishing a baseline from which to work, second, by identifying needs to fill in the gaps between what is known and achievable today and that which will be required before DQOs can be formulated, and third, by recommending measures that should be taken to assure that the DQOs in fact balance risk and cost with an achievable degree of certainty

  9. Full scale tests on remote handled FFTF fuel assembly waste handling and packaging

    International Nuclear Information System (INIS)

    Allen, C.R.; Cash, R.J.; Dawson, S.A.; Strode, J.N.

    1986-01-01

    Handling and packaging of remote handled, high activity solid waste fuel assembly hardware components from spent FFTF reactor fuel assemblies have been evaluated using full scale components. The demonstration was performed using FFTF fuel assembly components and simulated components which were handled remotely using electromechanical manipulators, shielding walls, master slave manipulators, specially designed grapples, and remote TV viewing. The testing and evaluation included handling, packaging for current and conceptual shipping containers, and the effects of volume reduction on packing efficiency and shielding requirements. Effects of waste segregation into transuranic (TRU) and non-transuranic fractions also are discussed

  10. Design and evaluation of a new ergonomic handle for instruments in minimally invasive surgery.

    Science.gov (United States)

    Sancibrian, Ramon; Gutierrez-Diez, María C; Torre-Ferrero, Carlos; Benito-Gonzalez, Maria A; Redondo-Figuero, Carlos; Manuel-Palazuelos, Jose C

    2014-05-01

    Laparoscopic surgery techniques have been demonstrated to provide massive benefits to patients. However, surgeons are subjected to hardworking conditions because of the poor ergonomic design of the instruments. In this article, a new ergonomic handle design is presented. This handle is designed using ergonomic principles, trying to provide both more intuitive manipulation of the instrument and a shape that reduces the high-pressure zones in the contact with the surgeon's hand. The ergonomic characteristics of the new handle were evaluated using objective and subjective studies. The experimental evaluation was performed using 28 volunteers by means of the comparison of the new handle with the ring-handle (RH) concept in an instrument available on the market. The volunteers' muscle activation and motions of the hand, wrist, and arm were studied while they performed different tasks. The data measured in the experiment include electromyography and goniometry values. The results obtained from the subjective analysis reveal that most volunteers (64%) preferred the new prototype to the RH, reporting less pain and less difficulty to complete the tasks. The results from the objective study reveal that the hyperflexion of the wrist required for the manipulation of the instrument is strongly reduced. The new ergonomic handle not only provides important ergonomic advantages but also improves the efficiency when completing the tasks. Compared with RH instruments, the new prototype reduced the high-pressure areas and the extreme motions of the wrist. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Prediction of pilot opinion ratings using an optimal pilot model. [of aircraft handling qualities in multiaxis tasks

    Science.gov (United States)

    Hess, R. A.

    1977-01-01

    A brief review of some of the more pertinent applications of analytical pilot models to the prediction of aircraft handling qualities is undertaken. The relative ease with which multiloop piloting tasks can be modeled via the optimal control formulation makes the use of optimal pilot models particularly attractive for handling qualities research. To this end, a rating hypothesis is introduced which relates the numerical pilot opinion rating assigned to a particular vehicle and task to the numerical value of the index of performance resulting from an optimal pilot modeling procedure as applied to that vehicle and task. This hypothesis is tested using data from piloted simulations and is shown to be reasonable. An example concerning a helicopter landing approach is introduced to outline the predictive capability of the rating hypothesis in multiaxis piloting tasks.

  12. an appraisal of fish processing and handling in yola north local ...

    African Journals Online (AJOL)

    Ibrahim Ahmed

    Sensory evaluation using Hedonic rating on a 7 point scale, the values of. 4.17, 3.11 and 2.11 were obtained .... Oman: Part1 Handling and Marketing System of. Fresh Fish. Journal of ... Ranganna, S., 1986. Handbook of Analysis and quality.

  13. Study and Evaluation of Innovative Fuel Handling Systems for Sodium-Cooled Fast Reactors: Fuel Handling Route Optimization

    Directory of Open Access Journals (Sweden)

    Franck Dechelette

    2014-01-01

    Full Text Available The research for technological improvement and innovation in sodium-cooled fast reactor is a matter of concern in fuel handling systems in a view to perform a better load factor of the reactor thanks to a quicker fuelling/defueling process. An optimized fuel handling route will also limit its investment cost. In that field, CEA has engaged some innovation study either of complete FHR or on the optimization of some specific components. This paper presents the study of three SFR fuel handling route fully described and compared to a reference FHR option. In those three FHR, two use a gas corridor to transfer spent and fresh fuel assembly and the third uses two casks with a sodium pot to evacuate and load an assembly in parallel. All of them are designed for the ASTRID reactor (1500 MWth but can be extrapolated to power reactors and are compatible with the mutualisation of one FHS coupled with two reactors. These three concepts are then intercompared and evaluated with the reference FHR according to four criteria: performances, risk assessment, investment cost, and qualification time. This analysis reveals that the “mixed way” FHR presents interesting solutions mainly in terms of design simplicity and time reduction. Therefore its study will be pursued for ASTRID as an alternative option.

  14. Adverse risk: a 'dynamic interaction model of patient moving and handling'.

    Science.gov (United States)

    Griffiths, Howard

    2012-09-01

    The aim of the present study was to examine patient adverse events associated with sub-optimal patient moving and handling. Few studies have examined the patient's perspective on adverse risk during manual handling episodes. A narrative review was undertaken to develop the 'Dynamic Interaction Model of Patient Moving and Handling' in an orthopaedic rehabilitation setting, using peer-reviewed publications published in English between 1992 and 2010. Five predominant themes emerged from the narrative review: 'patient's need to know about analgesics prior to movement/ambulation'; 'comfort care'; 'mastery of and acceptance of mobility aids/equipment'; 'psychological adjustment to fear of falling'; and 'the need for movement to prevent tissue pressure damage'. Prevalence of discomfort, pain, falls, pressure sores together with a specific Direct Instrument Nursing Observation (DINO) tool enable back care advisers to measure quality of patient manual handling. Evaluation of patients' use of mobility aids together with fear of falling may be important in determining patients' recovery trajectory. Clinical governance places a responsibility on nurse managers to consider quality of care for their service users. 'Dynamic Interaction Model of Nurse-Patient Moving and Handling' provides back care advisers, clinical risk managers and occupational health managers with an alternative perspective to clinical risk and occupational risk. © 2011 Blackwell Publishing Ltd.

  15. Preoperational checkout of the remote-handled transuranic waste handling at the Waste Isolation Pilot Plant

    International Nuclear Information System (INIS)

    1987-09-01

    This plan describes the preoperational checkout for handling Remote-Handled Transuranic (RH-TRU) Wastes from their receipt at the Waste Isolation Pilot Plant (WIPP) to their emplacement underground. This plan identifies the handling operations to be performed, personnel groups responsible for executing these operations, and required equipment items. In addition, this plan describes the quality assurance that will be exercised throughout the checkout, and finally, it establishes criteria by which to measure the success of the checkout. 7 refs., 5 figs

  16. Uranium hexafluoride: A manual of good handling practices

    International Nuclear Information System (INIS)

    1991-10-01

    For many years, the US Department of Energy (DOE) and its predecessor agencies have shared with the nuclear industry their experience in the area of uranium hexafluoride (UF 6 ) shipping containers and handling procedures. The information contained in this manual updates information contained in earlier issues. It covers the essential aspects of UF 6 handling, cylinder filling and emptying, general principles of weighing and sampling, shipping, and the use of protective overpacks. The physical and chemical properties of UF 6 are also described and tabulated. The nuclear industry is responsible for furnishing its own shipping cylinders and suitable protective overpacks. A substantial effort has been made by the industry to standardize UF 6 cylinders, samples, and overpacks. The quality of feed materials is important to the safe and efficient operation of the enriching facilities, and the UF 6 product purity from the enriching facilities is equally important to the fuel fabricator, the utilities, the operators of research reactors, and other users. The requirements have been the impetus for an aggressive effort by DOE and its contractors to develop accurate techniques for sampling and for chemical and isotopic analysis. A quality control program is maintained within the DOE enriching facilities to ensure that the proper degree of accuracy and precision are obtained for all the required measurements. The procedures and systems described for safe handling of UF 6 presented in this document have been developed and evaluated in DOE facilities during more than 40 years of handling vast quantities of UF 6 . With proper consideration for its nuclear properties, UF 6 may be safely handled in essentially the same manner as any other corrosive and/or toxic chemical

  17. A heuristic approach to handle capacitated facility location problem evaluated using clustering internal evaluation

    Science.gov (United States)

    Sutanto, G. R.; Kim, S.; Kim, D.; Sutanto, H.

    2018-03-01

    One of the problems in dealing with capacitated facility location problem (CFLP) is occurred because of the difference between the capacity numbers of facilities and the number of customers that needs to be served. A facility with small capacity may result in uncovered customers. These customers need to be re-allocated to another facility that still has available capacity. Therefore, an approach is proposed to handle CFLP by using k-means clustering algorithm to handle customers’ allocation. And then, if customers’ re-allocation is needed, is decided by the overall average distance between customers and the facilities. This new approach is benchmarked to the existing approach by Liao and Guo which also use k-means clustering algorithm as a base idea to decide the facilities location and customers’ allocation. Both of these approaches are benchmarked by using three clustering evaluation methods with connectedness, compactness, and separations factors.

  18. Technical evaluation of gamma-irradiation pretreatment on quality preservation for fresh fish

    International Nuclear Information System (INIS)

    Ke, P.J.; Linke, B.A.; Lemon, D.W.

    1985-07-01

    A comprehensive review and evaluation on the use of gamma-irradiation for preserving fresh fish quality has been made. The advantages and limitations of using gamma-irradiation of less than 1 M rad have been re-evaluated and compared with previous tests at the Halifax laboratory in terms of physical, organoleptic and some post process quality assessments. Cod, mackerel, and scallop were chosen as the models for lean, fatty and shell fish respectively. The irradiation process can prevent bacterial spoilage in fish, particularly when chilling and/or handling practices are inadequate, but the potential catalytic influences on enzymatic and chemical deterioration during the post-mortem period should also be considered. Some considerations and reservations concerning the changes in overall quality for irradiated fish are discussed. Before more research is completed, the gamma-irradiation process should not be used for shellfish, fatty fish and various prepared and frozen fish products made from Canadian Atlantic species

  19. EVALUATION OF THE RECOMMENDED WEIGHT HANDLING LIMITS FOR LOADS IN JOINERIES

    Directory of Open Access Journals (Sweden)

    Nilton César Fiedler

    2008-06-01

    Full Text Available This study was conducted in three joineries on the South of Espírito Santo State, to analyze the weight lifted by workersduring joineries operations and to compare it with the weight limits recommended by National Institute of Occupational Safety andHealth (NIOSH. The moving of timber pieces was done manually. Data on weight handling were obtained by an accuracy scale. Thevertical and horizontal distances between load and body, the asymmetric angles and vertical displacements were obtained by directmeasurement. The lifting frequencies were analyzed throughout studies of time and movement, using a time series analysis andhandling difficult of evaluated loads through flow. According to the results, the highest load handling by workers were in the cutter andbuzzy saw machines, and was above the recommended weight limits, rendering this way of work inadequate to man.

  20. Recommendations for cask features for robotic handling from the Advanced Handling Technology Project

    International Nuclear Information System (INIS)

    Drotning, W.

    1991-02-01

    This report describes the current status and recent progress in the Advanced Handling Technology Project (AHTP) initiated to explore the use of advanced robotic systems and handling technologies to perform automated cask handling operations at radioactive waste handling facilities, and to provide guidance to cask designers on the impact of robotic handling on cask design. Current AHTP tasks have developed system mock-ups to investigate robotic manipulation of impact limiters and cask tiedowns. In addition, cask uprighting and transport, using computer control of a bridge crane and robot, were performed to demonstrate the high speed cask transport operation possible under computer control. All of the current AHTP tasks involving manipulation of impact limiters and tiedowns require robotic operations using a torque wrench. To perform these operations, a pneumatic torque wrench and control system were integrated into the tool suite and control architecture of the gantry robot. The use of captured fasteners is briefly discussed as an area where alternative cask design preferences have resulted from the influence of guidance for robotic handling vs traditional operations experience. Specific robotic handling experiences with these system mock-ups highlight a number of continually recurring design principles: (1) robotic handling feasibility is improved by mechanical designs which emphasize operation with limited dexterity in constrained workspaces; (2) clearances, tolerances, and chamfers must allow for operations under actual conditions with consideration for misalignment and imprecise fixturing; (3) successful robotic handling is enhanced by including design detail in representations for model-based control; (4) robotic handling and overall quality assurance are improved by designs which eliminate the use of loose, disassembled parts. 8 refs., 15 figs

  1. Considerations for evaluation and selection of solid waste handling apron conveyors

    Energy Technology Data Exchange (ETDEWEB)

    Lisiecki, H.G.

    1976-11-01

    Criteria to be used in evaluating and selecting conveyer equipment for facilities handling solid wastes, such as solid waste resource recovery facilities, are discussed. Types of conveyer pan design and chain mechanisms are described. It is concluded that the conveyer purchaser must be knowledgeable about the equipment available, the specific use of equipment, its performance specifications, and the overall maintenance and operating costs. (LCL)

  2. Process & Quality procedures for transport & handling activities

    CERN Document Server

    Böttcher, O

    2002-01-01

    To respect the detailed and complex planning of the LHC installation project it is essential to reduce possible faults in every technical service that can cause delays in the schedule. In order to ensure proper execution of transport and handling activities it is important to get detailed information from the clients as early as possible in order to do the planning and the organisation of the required resources. One procedure that requires greater focus in the future is the preparation of the resources. The goal is to prevent equipment breakdowns and accidents while executing transport and handling activities. In the LEP dismantling project multiple breakdowns of important cranes caused serious problems in the project schedule. For the LHC installation project similar incidents in the reliability of the equipment cannot be accepted because of the high sensitivity of the whole schedule. This paper shall outline the efforts and methods that are put in place in order to meet the LHC installation requirements.

  3. Evaluation of the Implementation of Good Handling Practices in Food and Beverage Areas of Hotels.

    Science.gov (United States)

    Serafim, A L; Hecktheuer, L H R; Stangarlin-Fiori, L; Medeiros, L B; Martello, L; Machado, C E

    2015-11-01

    Because of the major international-level events that have recently been held in Brazil, concerns about the sensory and hygienic-sanitary conditions of food have increased. The objective of this study was to evaluate the implementation of good handling practices in food and beverage areas of hotels, with and without outsourced professional intervention. We evaluated 19 food and beverage areas in hotels in Porto Alegre, Rio do Sul, Brazil, using a checklist that was developed by a municipal surveillance team based on existing laws for good handling practices. The evaluation was done by a skilled professional in the food safety area on two occasions, at the beginning of the study (January to May 2013) and at the end (July to November 2014), and the establishments were classified as good, regular, or poor. After the baseline evaluation, an action plan listing the noncompliance found at each location was given to those responsible for the establishments, and a period of 1 year 6 months was stipulated for improvements to be made. In the repeat evaluation, those responsible for the establishments were asked whether they had hired an outsourced professional to assist them in the improvements. The hotels showed improvement during the repeat evaluation, but a significant increase in the percentage of overall adequacy was seen only in the food and beverages areas of the 12 hotels that used the intervention of an outsourced professional. The better percentage of adequacy in establishments with outsourced professional intervention underlines the importance of an external and impartial view of routine activities in the implementation of good handling practices.

  4. Scheduling of outbound luggage handling at airports

    DEFF Research Database (Denmark)

    Barth, Torben C.; Pisinger, David

    2012-01-01

    This article considers the outbound luggage handling problem at airports. The problem is to assign handling facilities to outbound flights and decide about the handling start time. This dynamic, near real-time assignment problem is part of the daily airport operations. Quality, efficiency......). Another solution method is a decomposition approach. The problem is divided into different subproblems and solved in iterative steps. The different solution approaches are tested on real world data from Frankfurt Airport....

  5. The development and evaluation of a stereoscopic television system for remote handling

    International Nuclear Information System (INIS)

    Dumbreck, A.A.; Murphy, S.P.; Smith, C.W.

    1990-01-01

    This paper describes the development and evaluation of a stereoscopic television system at Harwell Laboratory. The theory of stereo image geometry is outlined, and criteria for the matching of stereoscopic pictures are given. A stereoscopic television system designed for remote handling tasks has been produced, it provides two selectable angles of view and variable convergence, the display is viewed via polarizing spectacles. Evaluations have indicated improved performance with no problems of operator fatigue over a wide range of applications. (author)

  6. Honey Quality as Affected by Handling, Processing and Marketing Channels in Uganda

    Directory of Open Access Journals (Sweden)

    Nabakabya, D.

    2008-01-01

    Full Text Available The factors that affect honey quality in Uganda were surveyed in 120 beekeeping households. Honey was sampled from supermarkets, hawkers and stall markets along four transects across Kampala, the capital. Honey quality parameters assessed were diastase number (DN, free acidity (FA, moisture content (MC, hydroxymethylfurfural (HMF, and water insoluble solids (WIS. Honey was mostly harvested from basket and grass hives. Pressing, boiling and straining were popular honey processing methods. Honey quality was mainly compromised by harvesting immature honey, bad extraction methods and contamination by extraneous materials. Constraints to beekeeping were lack of appropriate equipment (52%, inadequate farmer skills, bad weather and vermin. Honey brands differed (P< 0.05 in DN, most failed the Uganda and Codex Alimentarius standards, and 20% met European Union HMF and DN standards. Correlation was observed between HMF vs. DN (r= 0.94; MC vs. FA (r= 0.56. Supermarket honey (4.65 was more superior (P< 0.05 in DN than stall markets (1.93, and hawkers (2.3. Similarly, WIS levels differed (P< 0.05 between honeys from supermarkets (0.08, stall markets (3.0 and hawkers (3.15. All honeys met MC standards, while DN and WIS were major shortcomings. Farmer training and extension in proper honey harvesting, handling and processing should be strengthened. Quality monitoring at all levels should be emphasized.

  7. Handling Qualities Flight Testing of the Stratospheric Observatory for Infrared Astronomy (SOFIA)

    Science.gov (United States)

    Glaser, Scott T.; Strovers, Brian K.

    2011-01-01

    Airborne infrared astronomy has a long successful history, albeit relatively unknown outside of the astronomy community. A major problem with ground based infrared astronomy is the absorption and scatter of infrared energy by water in the atmosphere. Observing the universe from above 40,000 ft puts the observation platform above 99% of the water vapor in the atmosphere, thereby addressing this problem at a fraction of the cost of space based systems. The Stratospheric Observatory For Infrared Astronomy (SOFIA) aircraft is the most ambitious foray into the field of airborne infrared astronomy in history. Using a 747SP (The Boeing Company, Chicago, Illinois) aircraft modified with a 2.5m telescope located in the aft section of the fuselage, the SOFIA endeavors to provide views of the universe never before possible and at a fraction of the cost of space based systems. The modification to the airplane includes moveable doors and aperture that expose the telescope assembly. The telescope assembly is aimed and stabilized using a multitude of on board systems. This modification has the potential to cause aerodynamic anomalies that could induce undesired forces either at the cavity itself or indirectly due to interference with the empennage, both of which could cause handling qualities issues. As a result, an extensive analysis and flight test program was conducted from December 2009 through March 2011. Several methods, including a Lower Order Equivalent Systems analysis and pilot assessment, were used to ascertain the effects of the modification. The SOFIA modification was found to cause no adverse handling qualities effects and the aircraft was cleared for operational use. This paper discusses the history and modification to the aircraft, development of test procedures and analysis, results of testing and analysis, lessons learned for future projects and justification for operational certification.

  8. Importance of fruit variability in the assessment of apple quality by sensory evaluation

    DEFF Research Database (Denmark)

    Bavay, Cécile; Symoneaux, Ronan; Maître, Isabelle

    2013-01-01

    cultivars, apples were sorted into homogenous acoustic firmness categories within each cultivar. The discrimination ability of the trained panel was observed not only between cultivars but also within each cultivar for crunchiness, firmness, juiciness and acidity. Following these results, a mixed......The assessment of produce quality is a major aspect of applied postharvest biology. Horticultural researchers working on organoleptic quality of fruit need objective methods for the evaluation of sensory properties. The development of sensory methodologies specifically for apples highlighted...... the problem of handling variation due to fruit variability and assessor differences. The aim of this study was to investigate the weight of within-batch variability in sensory evaluation of apples and to propose a methodology that accounts for this variability. Prior to sensory analysis, for three apple...

  9. Evaluation of structure integrity of the lifting handle of CRB

    Energy Technology Data Exchange (ETDEWEB)

    Wu, S.-Y. [Radiation Protection Association, Taiwan (China); Lin, S.-R. [Radiation Protection Association, Taiwan (China)], E-mail: srlin@iner.gov.tw; Kang, L.-C. [Institute of Nuclear Energy Research, Taiwan (China); Chang, Han-Jou [Department of Nuclear Safety, TPC, Taiwan (China)

    2008-09-15

    Since visual inspection was applied to inspect the control rod blades (CRBs) of nuclear power plants in Taiwan, indications have been found in areas such as roller-pin hole, sheath and tie-rod of CRB. Many preliminary safety analyses with conservative assumptions have been conducted to endorse the continuing operation of the units. The objective of this study is to evaluate the structural integrity of those CRBs during lifting operation. Detailed finite element models of the lifting handle of the CRB are built with emphasis on the postulated crack near the roller-pin hole. Both the D-215 type CRB and the Marathon type CRB are evaluated. It is concluded that the structural integrity is guaranteed even under the worst postulated situation.

  10. Pre-slaughter stress and pork quality

    Science.gov (United States)

    Stajković, S.; Teodorović, V.; Baltić, M.; Karabasil, N.

    2017-09-01

    Stress is an inevitable consequence of handling of animals for slaughter. Stress conditions during transport, lairage and at slaughter induce undesirable effects on the end quality of meat such as pale, soft, exudative meat and dark firm dry meat. Hence, it is very important to define appropriate parameters for objective assessment of level of stress. Attempts to define measures of stress have been difficult and no physiological parameter has been successfully used to evaluate stress situations. One physiological change in swine associated with animal handling stress and with pork quality is an increase in blood lactate concentration. Plasma cortisol was thought to be an appropriate indicator of stress, but the concentration was not consistently changed by different stressors. Therefore, finding alternative parameters reacting to stressors, such as acute phase proteins, would be of great value for the objective evaluation of level of stress and meat quality. As the stress during pre-slaughter handling is unavoidable, the final goal is to improve transport and slaughter conditions for the animal and, as a consequence, meat quality and animal welfare.

  11. Handling chemotherapy drugs-Do medical gloves really protect?

    Science.gov (United States)

    Landeck, Lilla; Gonzalez, Ernesto; Koch, Olaf Manfred

    2015-10-15

    Due to their potential mutagenic, carcinogenic and teratogenic effects occupational exposure to chemotherapy drugs should be kept to a minimum. Utilization of personnel protective devices, especially the use of protective medical gloves, is a mainstay to avoid skin contact. The choice of appropriate gloves is of outstanding importance. For optimal protection in the oncology setting it is essential to establish general guidelines evaluating appropriate materials and defining quality standards. Establishing these guidelines can facilitate better handling and avoid potential hazards and late sequelae. In Europe there are no specific requirements or test methodologies for medical gloves used in the oncology environment. The implementation of uniform standards for gloves used while handling chemotherapy drugs would be desirable. In contrast, in the US medical gloves used to handle chemotherapy drugs have to fulfill requirements according to the ASTM International (American Society of Testing and Materials) standard D 6978-05. Nitrile or natural rubber latex is a preferred basic glove material, while vinyl is considered inappropriate because of its generally increased permeability. For extended exposure to chemotherapy drugs, double gloving, the use of thicker gloves and the frequent change of gloves increases their protective power. © 2014 UICC.

  12. MANU. Handling of bentonite prior buffer block manufacturing

    International Nuclear Information System (INIS)

    Laaksonen, R.

    2010-01-01

    The aim of this study is to describe the entire bentonite handling process starting from freight from harbour to storage facility and ending up to the manufacturing filling process of the bentonite block moulds. This work describes the bentonite handling prior to the process in which bentonite blocks are manufactured in great quantities. This work included a study of relevant Nordic and international well documented cases of storage, processing and techniques involving bentonite material. Information about storage and handling processes from producers or re-sellers of bentonite was collected while keeping in mind the requirements coming from the Posiva side. Also a limited experiment was made for humidification of different material types. This work includes a detailed description of methods and equipment needed for bentonite storage and processing. Posiva Oy used Jauhetekniikka Oy as a consultant to prepare handling process flow charts for bentonite. Jauhetekniikka Oy also evaluated the content of this report. The handling of bentonite was based on the assumption that bentonite process work is done in one factory for 11 months of work time while the weekly volume is around 41-45 tons. Storage space needed in this case is about 300 tons of bentonite which equals about seven weeks of raw material consumption. This work concluded several things to be carefully considered: sampling at various phases of the process, the air quality at the production/storage facilities (humidity and temperature), the level of automation/process control of the manufacturing process and the means of producing/saving data from different phases of the process. (orig.)

  13. Evaluation of robot performance: placement of rings with handles at ISIS

    International Nuclear Information System (INIS)

    Lefaure, C.; Seror, V.; Lochard, J.

    1989-07-01

    The first task performed by CEPN in the field of evaluating the robotics was to identify principal parameters to be taken into account for estimating the cost and the efficiency of such action. After this work, EDF-UTO demanded CEPN to develop a methodology for evaluating economic and dosimetry impacts of introducing robots or remote handling in operation and maintenance of PWR-900 and PWR-1300 plants. These operations are mostly originating from failures causing exposure of personnel. Objective of the first study presented in this report is to evaluate the value of replacing classic annual procedure of fixing the primary tubes of PWR steam generators by robot. Estimated value of collective dose was obtained by PANTHERE-RP and SEPTEN codes for dose calculation and DOSI-ANA for taking into account the duration of operation. It has been found that application of ISIS handle enable to reduce the collective dose approximately by a factor of 4 (5.2 H.rem for automated operation, compared to 23.5 H.rem for manual option) although the amount of work is increased by a factor of 3, meaning the work in the zone where exposure is significant (160 hours for automatized option compared to 59 hours of manual operation). Application od ISIS enable to decrease almost completely the exposure related to the phase of installing the support rings (0.3 H.rem with ISIS compared to 20 for the manual option). On the contrary, installation of ISIS cause additional collective exposure of 3 H.rem. This lead to a conclusion that application of ISIS can be justified if avoided doses are equal or more than 3 H.rem [fr

  14. New, clean handling process introduced to improve cable quality

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, C G

    1990-05-01

    The clean room system introduced by Canada Wire and Cable Limited in its Toronto plant for its cable manufacturing operation is described. While clean room technology is common in the food processing industry, optical and aerospace manufacturing processes, this is the first time it has been applied to wire and cable extrusion in North America. The purpose of the clean compound handling system is to prevent particle contamination in the shielding and cable insulation materials, as part of an effort to prevent premature underground electric cable failures. Two rooms are dedicated to handling different types of insulation compound, two are dedicated to receiving semi-conducting shielding material, and the fifth room functions as an air lock for the two insulation rooms. The atmosphere is highly regulated with programmable logic control. The air supply filters capture 99.97% of all particles 0.3 microns or larger. The system also maintains air temperature, relative humidity and static pressure. The life variability of cross-linked polyethylene primary distribution cable is dependant on five factors: material purity, extra clean compound handling, cable design, manufacturing process, and installation and operation practices. The clean room system is expected to result in cable that is more resistant to water treeing failures. 2 figs.

  15. Complying with US and European complaint handling requirements.

    Science.gov (United States)

    Donawa, M E

    1997-09-01

    The importance of customer complaints for providing valuable information on the use of medical devices is clearly reflected in United States (US) and European quality system requirements for handling complaints. However, there are significant differences in US and European complaint handling requirements. This article will discuss those differences and methods for ensuring compliance.

  16. Evaluation of the ARCHITECT urine NGAL assay: Assay performance, specimen handling requirements and biological variability

    NARCIS (Netherlands)

    Grenier, F.C.; Ali, S.; Syed, H.; Workman, R.; Martens, F.; Liao, M.; Wang, Y.; Wong, P.Y.

    2010-01-01

    Objectives: NGAL (Neutrophil Gelatinase-Associated Lipocalin) has emerged as a new biomarker for the identification of acute kidney injury. Reliable clinical evaluations require a simple, robust test method for NGAL, and knowledge of specimen handling and specimen stability characteristics. We

  17. CANISTER HANDLING FACILITY CRITICALITY SAFETY CALCULATIONS

    International Nuclear Information System (INIS)

    C.E. Sanders

    2005-01-01

    This design calculation revises and updates the previous criticality evaluation for the canister handling, transfer and staging operations to be performed in the Canister Handling Facility (CHF) documented in BSC [Bechtel SAIC Company] 2004 [DIRS 167614]. The purpose of the calculation is to demonstrate that the handling operations of canisters performed in the CHF meet the nuclear criticality safety design criteria specified in the ''Project Design Criteria (PDC) Document'' (BSC 2004 [DIRS 171599], Section 4.9.2.2), the nuclear facility safety requirement in ''Project Requirements Document'' (Canori and Leitner 2003 [DIRS 166275], p. 4-206), the functional/operational nuclear safety requirement in the ''Project Functional and Operational Requirements'' document (Curry 2004 [DIRS 170557], p. 75), and the functional nuclear criticality safety requirements described in the ''Canister Handling Facility Description Document'' (BSC 2004 [DIRS 168992], Sections 3.1.1.3.4.13 and 3.2.3). Specific scope of work contained in this activity consists of updating the Category 1 and 2 event sequence evaluations as identified in the ''Categorization of Event Sequences for License Application'' (BSC 2004 [DIRS 167268], Section 7). The CHF is limited in throughput capacity to handling sealed U.S. Department of Energy (DOE) spent nuclear fuel (SNF) and high-level radioactive waste (HLW) canisters, defense high-level radioactive waste (DHLW), naval canisters, multicanister overpacks (MCOs), vertical dual-purpose canisters (DPCs), and multipurpose canisters (MPCs) (if and when they become available) (BSC 2004 [DIRS 168992], p. 1-1). It should be noted that the design and safety analyses of the naval canisters are the responsibility of the U.S. Department of the Navy (Naval Nuclear Propulsion Program) and will not be included in this document. In addition, this calculation is valid for the current design of the CHF and may not reflect the ongoing design evolution of the facility

  18. Magnetic resonance imaging of meniscal bucket-handle tears

    International Nuclear Information System (INIS)

    Dfouni, N.; Garcia, J.; Kindynis, Ph.; Bosson, D.

    1997-01-01

    To define MR signs of meniscal bucket-handle tears and evaluate the diagnostic efficiency of this technique. Retrospective study of 30 patients with a meniscal bucket-handle tear and 30 with a different type of tear, all proven by arthroscopy. The following MR signs of a bucket-handle tear were evaluated: 'separate meniscal fragment, 'double posterior cruciate ligament', 'snake sign' and 'double anterior horn'. A correct diagnosis of a bucket-handle tear was only made in 18/30 of patients. Several of the MR signs were seen in the same patient in 17 cases. A double posterior cruciate ligament was present only in cases of medial meniscus tears. The 12 menisci without these signs, and therefore not diagnosed as bucket-handle tears, were all classified as meniscal tears on the basis of signal extending to the meniscal surface. Nine of these were not displaced into the inter-condylar notch at arthroscopy. The interobserver agreement was excellent: kappa 0.88. The diagnosis of a bucket-handle meniscal tear, if it is displaced, can be made when one or more of the four MR evaluated signs are present. Other forms of meniscal tears are only exceptionally diagnosed as bucket-handle tears. (authors)

  19. Evaluation of a New Remote Handling Design for High Throughput Annular Centrifugal Contactors

    International Nuclear Information System (INIS)

    Meikrantz, David H.; Garn, Troy G.; Law, Jack D.; Macaluso, Lawrence L.

    2009-01-01

    Advanced designs of nuclear fuel recycling plants are expected to include more ambitious goals for aqueous based separations including; higher separations efficiency, high-level waste minimization, and a greater focus on continuous processes to minimize cost and footprint. Therefore, Annular Centrifugal Contactors (ACCs) are destined to play a more important role for such future processing schemes. Previous efforts defined and characterized the performance of commercial 5 cm and 12.5 cm single-stage ACCs in a 'cold' environment. The next logical step, the design and evaluation of remote capable pilot scale ACCs in a 'hot' or radioactive environment was reported earlier. This report includes the development of remote designs for ACCs that can process the large throughput rates needed in future nuclear fuel recycling plants. Novel designs were developed for the remote interconnection of contactor units, clean-in-place and drain connections, and a new solids removal collection chamber. A three stage, 12.5 cm diameter rotor module has been constructed and evaluated for operational function and remote handling in highly radioactive environments. This design is scalable to commercial CINC ACC models from V-05 to V-20 with total throughput rates ranging from 20 to 650 liters per minute. The V-05R three stage prototype was manufactured by the commercial vendor for ACCs in the U.S., CINC mfg. It employs three standard V-05 clean-in-place (CIP) units modified for remote service and replacement via new methods of connection for solution inlets, outlets, drain and CIP. Hydraulic testing and functional checks were successfully conducted and then the prototype was evaluated for remote handling and maintenance suitability. Removal and replacement of the center position V-05R ACC unit in the three stage prototype was demonstrated using an overhead rail mounted PaR manipulator. This evaluation confirmed the efficacy of this innovative design for interconnecting and cleaning

  20. CANISTER HANDLING FACILITY CRITICALITY SAFETY CALCULATIONS

    Energy Technology Data Exchange (ETDEWEB)

    C.E. Sanders

    2005-04-07

    This design calculation revises and updates the previous criticality evaluation for the canister handling, transfer and staging operations to be performed in the Canister Handling Facility (CHF) documented in BSC [Bechtel SAIC Company] 2004 [DIRS 167614]. The purpose of the calculation is to demonstrate that the handling operations of canisters performed in the CHF meet the nuclear criticality safety design criteria specified in the ''Project Design Criteria (PDC) Document'' (BSC 2004 [DIRS 171599], Section 4.9.2.2), the nuclear facility safety requirement in ''Project Requirements Document'' (Canori and Leitner 2003 [DIRS 166275], p. 4-206), the functional/operational nuclear safety requirement in the ''Project Functional and Operational Requirements'' document (Curry 2004 [DIRS 170557], p. 75), and the functional nuclear criticality safety requirements described in the ''Canister Handling Facility Description Document'' (BSC 2004 [DIRS 168992], Sections 3.1.1.3.4.13 and 3.2.3). Specific scope of work contained in this activity consists of updating the Category 1 and 2 event sequence evaluations as identified in the ''Categorization of Event Sequences for License Application'' (BSC 2004 [DIRS 167268], Section 7). The CHF is limited in throughput capacity to handling sealed U.S. Department of Energy (DOE) spent nuclear fuel (SNF) and high-level radioactive waste (HLW) canisters, defense high-level radioactive waste (DHLW), naval canisters, multicanister overpacks (MCOs), vertical dual-purpose canisters (DPCs), and multipurpose canisters (MPCs) (if and when they become available) (BSC 2004 [DIRS 168992], p. 1-1). It should be noted that the design and safety analyses of the naval canisters are the responsibility of the U.S. Department of the Navy (Naval Nuclear Propulsion Program) and will not be included in this document. In addition, this calculation is valid for

  1. Quality control and data-handling in multicentre studies: the case of the Multicentre Project for Tuberculosis Research

    Directory of Open Access Journals (Sweden)

    Caloto Teresa

    2001-12-01

    Full Text Available Abstract Background The Multicentre Project for Tuberculosis Research (MPTR was a clinical-epidemiological study on tuberculosis carried out in Spain from 1996 to 1998. In total, 96 centres scattered all over the country participated in the project, 19935 "possible cases" of tuberculosis were examined and 10053 finally included. Data-handling and quality control procedures implemented in the MPTR are described. Methods The study was divided in three phases: 1 preliminary phase, 2 field work 3 final phase. Quality control procedures during the three phases are described. Results: Preliminary phase: a organisation of the research team; b design of epidemiological tools; training of researchers. Field work: a data collection; b data computerisation; c data transmission; d data cleaning; e quality control audits; f confidentiality. Final phase: a final data cleaning; b final analysis. Conclusion The undertaking of a multicentre project implies the need to work with a heterogeneous research team and yet at the same time attain a common goal by following a homogeneous methodology. This demands an additional effort on quality control.

  2. Harvesting and handling agricultural residues for energy

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, B.M.; Summer, H.R.

    1986-05-01

    Significant progress in understanding the needs for design of agricultural residue collection and handling systems has been made but additional research is required. Recommendations are made for research to (a) integrate residue collection and handling systems into general agricultural practices through the development of multi-use equipment and total harvest systems; (b) improve methods for routine evaluation of agricultural residue resources, possibly through remote sensing and image processing; (c) analyze biomass properties to obtain detailed data relevant to engineering design and analysis; (d) evaluate long-term environmental, social, and agronomic impacts of residue collection; (e) develop improved equipment with higher capacities to reduce residue collection and handling costs, with emphasis on optimal design of complete systems including collection, transportation, processing, storage, and utilization; and (f) produce standard forms of biomass fuels or products to enhance material handling and expand biomass markets through improved reliability and automatic control of biomass conversion and other utilization systems. 118 references.

  3. Quality assurance system in the production process of the gamma shielding devices used for transport and handling of radiopharmaceuticals and labelled compounds at Cuba

    International Nuclear Information System (INIS)

    Zuniga Santana, Juan F.; Fernandez Rondon, Manuel; Viante Garrido, Enrique; Berdeguez, Mirta B.T.; Rodriguez Perez, Hilario

    1999-01-01

    The paper shows how a Quality Assurance System for the process of production of gamma shielding devices has been conceived, designed and implemented. Special emphasis is given to the necessity of utilizing tools of control statistic in order to guaranteed the quality in the serial production process of such devices used in the transport, storage and handling of radioactive materials.(author)

  4. A review on bicycle and motorcycle rider control with a perspective on handling qualities

    Science.gov (United States)

    Kooijman, J. D. G.; Schwab, A. L.

    2013-11-01

    This paper is a review study on handling and control of bicycles and motorcycles, the so-called single-track vehicles. The first part gives a brief overview on the modelling of the dynamics of single-track vehicles and the experimental validation. The second part focusses on a review of modelling and measuring human rider control. The third part deals with the concepts of handling and manoeuvrability and their experimental validation. Parallels are drawn with the literature on aircraft handling and pilot models. The paper concludes with the open ends and promising directions for future work in the field of handling and control of single-track vehicles.

  5. Diet quality and cognitive function in an urban sample: findings from the Healthy Aging in Neighborhoods of Diversity across the Life Span (HANDLS) study.

    Science.gov (United States)

    Wright, Regina S; Waldstein, Shari R; Kuczmarski, Marie Fanelli; Pohlig, Ryan T; Gerassimakis, Constance S; Gaynor, Beatrice; Evans, Michele K; Zonderman, Alan B

    2017-01-01

    Poor diet quality contributes to morbidity, including poor brain health outcomes such as cognitive decline and dementia. African Americans and individuals living in poverty may be at greater risk for cognitive decrements from poor diet quality. Cross-sectional. Baltimore, MD, USA. Participants were 2090 African Americans and Whites (57 % female, mean age=47·9 years) who completed two 24 h dietary recalls. We examined cognitive performance and potential interactions of diet quality with race and poverty status using baseline data from the Healthy Aging in Neighborhoods of Diversity across the Life Span (HANDLS) study. Healthy Eating Index-2010 (HEI-2010) scores were calculated and interpreted using federal guidelines. A neurocognitive test battery was administered to evaluate cognitive function over several domains. Linear regression analyses showed that lower HEI-2010 scores were associated with poorer verbal learning and memory (PDiet quality within the sample was poor. Significant interactions of HEI-2010 and poverty status (all Pdiet quality was associated with higher performance on tests of attention and cognitive flexibility, visuospatial ability and perceptual speed among those below the poverty line. No significant race interactions emerged. Higher diet quality was associated with better performance on two measures of verbal learning and memory, irrespective of race and poverty status. Findings suggest that diet quality and cognitive function are likely related at the population level. Future research is needed to determine whether the association is clinically significant.

  6. High-definition television evaluation for remote handling task performance

    International Nuclear Information System (INIS)

    Fujita, Y.; Omori, E.; Hayashi, S.; Draper, J.V.; Herndon, J.N.

    1986-01-01

    In a plant that employs remote handling techniques for equipment maintenance, operators perform maintenance tasks primarily by using the information from television systems. The efficiency of the television system has a significant impact on remote maintenance task performance. High-definition television (HDTV) transmits a video image with more than twice the number of horizontal scan lines as standard-resolution television (1125 for HDTV to 525 for standard-resolution NTSC television). The added scan lines dramatically improve the resolution of images on the HDTV monitors. This paper describes experiments designed to evaluate the impact of HDTV on the performance of typical remote tasks. The experiments described in this paper compared the performance of four operators using HDTV with their performance while using other television systems. The experiments included four television systems: (a) high-definition color television, (b) high-definition monochromatic television, (c) standard-resolution monochromatic television, and (d) standard-resolution stereoscopic monochromatic television

  7. Software component quality evaluation

    Science.gov (United States)

    Clough, A. J.

    1991-01-01

    The paper describes a software inspection process that can be used to evaluate the quality of software components. Quality criteria, process application, independent testing of the process and proposed associated tool support are covered. Early results indicate that this technique is well suited for assessing software component quality in a standardized fashion. With automated machine assistance to facilitate both the evaluation and selection of software components, such a technique should promote effective reuse of software components.

  8. Evaluation of some handling and processing parameters for ...

    African Journals Online (AJOL)

    Biomass materials require reduction and densification for the purpose of handling and space requirements. Guinea corn (Sorghum bi-color) is a major source of biomass material in the tropic regions. The densification process involves some measurable parameters, namely: pressure, particles size and binder ratio. Guinea ...

  9. Introducing modified TypeScript in an existing framework to improve error handling

    OpenAIRE

    Minder, Patrik

    2016-01-01

    Error messages in compilers is a topic that is often overlooked. The quality of the messages can have a big impact on development time and ease oflearning. Another method used to speed up development is to build a domainspecific language (DSL). This thesis migrates an existing framework to use TypeScript in order to speed up development time with compile-time error handling. Alternative methods for implementing a DSL are evaluated based onhow they affect the ability to generate good error mes...

  10. Epidemiological and biomechanical evaluation of airline baggage handling.

    Science.gov (United States)

    Tafazzol, Alireza; Aref, Samin; Mardani, Majid; Haddad, Omid; Parnianpour, Mohamad

    2016-01-01

    Musculoskeletal disorders (MSDs) are prevalent among airline baggage handlers due to manual materials handling. In this study, the Nordic musculoskeletal questionnaire (NMQ), the revised National Institute for Occupational Safety and Health (NIOSH) lifting equation, and the University of Michigan 3D Static Strength Prediction Program™ (3DSSPP) were used to analyze MSDs among baggage handlers. The NMQ was filled out by 209 baggage handlers and 46 arbitrarily selected baggage handlers were evaluated using the NIOSH method and 3DSSPP. The obtained results showed that the most common MSDs occurred in the lower back region. The next risky regions included knees, neck, and upper back, respectively. The NIOSH results confirmed that the subjects lifted loads heavier than the permitted limit and their lifting postures were inappropriate. The results of the 3DSSPP also indicated that compression forces exceeded the NIOSH limit in these awkward postures. Relying on this study, holding compulsory ergonomic lifting training courses could be proposed for workers and regulations adjusting an upper limit for maximum baggage weight must be also enacted in order to improve occupational health and prevent the prevalence of increasing MSDs.

  11. Evaluation of the Total Cost of Ownership of Fuel Cell-Powered Material Handling Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Ramsden, T.

    2013-04-01

    This report discusses an analysis of the total cost of ownership of fuel cell-powered and traditional battery-powered material handling equipment (MHE, or more typically 'forklifts'). A number of fuel cell MHE deployments have received funding support from the federal government. Using data from these government co-funded deployments, DOE's National Renewable Energy Laboratory (NREL) has been evaluating the performance of fuel cells in material handling applications. NREL has assessed the total cost of ownership of fuel cell MHE and compared it to the cost of ownership of traditional battery-powered MHE. As part of its cost of ownership assessment, NREL looked at a range of costs associated with MHE operation, including the capital costs of battery and fuel cell systems, the cost of supporting infrastructure, maintenance costs, warehouse space costs, and labor costs. Considering all these costs, NREL found that fuel cell MHE can have a lower overall cost of ownership than comparable battery-powered MHE.

  12. SRTC criticality technical review: Nuclear Criticality Safety Evaluation 93-18 Uranium Solidification Facility's Waste Handling Facility

    International Nuclear Information System (INIS)

    Rathbun, R.

    1993-01-01

    Separate review of NMP-NCS-930058, open-quotes Nuclear Criticality Safety Evaluation 93-18 Uranium Solidification Facility's Waste Handling Facility (U), August 17, 1993,close quotes was requested of SRTC Applied Physics Group. The NCSE is a criticality assessment to determine waste container uranium limits in the Uranium Solidification Facility's Waste Handling Facility. The NCSE under review concludes that the NDA room remains in a critically safe configuration for all normal and single credible abnormal conditions. The ability to make this conclusion is highly dependent on array limitation and inclusion of physical barriers between 2x2x1 arrays of boxes containing materials contaminated with uranium. After a thorough review of the NCSE and independent calculations, this reviewer agrees with that conclusion

  13. Remote-Handled Low-Level Waste Disposal Project Alternatives Analysis

    Energy Technology Data Exchange (ETDEWEB)

    David Duncan

    2011-04-01

    This report identifies, evaluates, and compares alternatives for meeting the U.S. Department of Energy’s mission need for management of remote-handled low-level waste generated by the Idaho National Laboratory and its tenants. Each alternative identified in the Mission Need Statement for the Remote-Handled Low-Level Waste Treatment Project is described and evaluated for capability to fulfill the mission need. Alternatives that could meet the mission need are further evaluated and compared using criteria of cost, risk, complexity, stakeholder values, and regulatory compliance. The alternative for disposal of remote-handled low-level waste that has the highest confidence of meeting the mission need and represents best value to the government is to build a new disposal facility at the Idaho National Laboratory Site.

  14. Remote-Handled Low Level Waste Disposal Project Alternatives Analysis

    Energy Technology Data Exchange (ETDEWEB)

    David Duncan

    2010-10-01

    This report identifies, evaluates, and compares alternatives for meeting the U.S. Department of Energy’s mission need for management of remote-handled low-level waste generated by the Idaho National Laboratory and its tenants. Each alternative identified in the Mission Need Statement for the Remote-Handled Low-Level Waste Treatment Project is described and evaluated for capability to fulfill the mission need. Alternatives that could meet the mission need are further evaluated and compared using criteria of cost, risk, complexity, stakeholder values, and regulatory compliance. The alternative for disposal of remote-handled low-level waste that has the highest confidence of meeting the mission need and represents best value to the government is to build a new disposal facility at the Idaho National Laboratory Site.

  15. Remote-Handled Low-Level Waste Disposal Project Alternatives Analysis

    Energy Technology Data Exchange (ETDEWEB)

    David Duncan

    2011-03-01

    This report identifies, evaluates, and compares alternatives for meeting the U.S. Department of Energy’s mission need for management of remote-handled low-level waste generated by the Idaho National Laboratory and its tenants. Each alternative identified in the Mission Need Statement for the Remote-Handled Low-Level Waste Treatment Project is described and evaluated for capability to fulfill the mission need. Alternatives that could meet the mission need are further evaluated and compared using criteria of cost, risk, complexity, stakeholder values, and regulatory compliance. The alternative for disposal of remote-handled low-level waste that has the highest confidence of meeting the mission need and represents best value to the government is to build a new disposal facility at the Idaho National Laboratory Site.

  16. Remote-Handled Low-Level Waste Disposal Project Alternatives Analysis

    Energy Technology Data Exchange (ETDEWEB)

    David Duncan

    2010-06-01

    This report identifies, evaluates, and compares alternatives for meeting the U.S. Department of Energy’s mission need for management of remote-handled low-level waste generated by the Idaho National Laboratory and its tenants. Each alternative identified in the Mission Need Statement for the Remote-Handled Low-Level Waste Treatment Project is described and evaluated for capability to fulfill the mission need. Alternatives that could meet the mission need are further evaluated and compared using criteria of cost, risk, complexity, stakeholder values, and regulatory compliance. The alternative for disposal of remote-handled low-level waste that has the highest confidence of meeting the mission need and represents best value to the government is to build a new disposal facility at the Idaho National Laboratory Site.

  17. Evaluating ITER remote handling middleware concepts

    International Nuclear Information System (INIS)

    Koning, J.F.; Heemskerk, C.J.M.; Schoen, P.; Smedinga, D.; Boode, A.H.; Hamilton, D.T.

    2013-01-01

    Highlights: ► Remote Handling Study Centre: middleware system setup and modules built. ► Aligning to ITER RH Control System Layout: prototype of database, VR and simulator. ► OpenSplice DDS, ZeroC ICE messaging and object oriented middlewares reviewed. ► Windows network latency found problematic for semi-realtime control over the network. -- Abstract: Remote maintenance activities in ITER will be performed by a unique set of hardware systems, supported by an extensive software kit. A layer of middleware will manage and control a complex set of interconnections between teams of operators, hardware devices in various operating theatres, and databases managing tool and task logistics. The middleware is driven by constraints on amounts and timing of data like real-time control loops, camera images, and database access. The Remote Handling Study Centre (RHSC), located at FOM institute DIFFER, has a 4-operator work cell in an ITER relevant RH Control Room setup which connects to a virtual hot cell back-end. The centre is developing and testing flexible integration of the Control Room components, resulting in proof-of-concept tests of this middleware layer. SW components studied include generic human-machine interface software, a prototype of a RH operations management system, and a distributed virtual reality system supporting multi-screen, multi-actor, and multiple independent views. Real-time rigid body dynamics and contact interaction simulation software supports simulation of structural deformation, “augmented reality” operations and operator training. The paper presents generic requirements and conceptual design of middleware components and Operations Management System in the context of a RH Control Room work cell. The simulation software is analyzed for real-time performance and it is argued that it is critical for middleware to have complete control over the physical network to be able to guarantee bandwidth and latency to the components

  18. Evaluating ITER remote handling middleware concepts

    Energy Technology Data Exchange (ETDEWEB)

    Koning, J.F., E-mail: j.f.koning@differ.nl [FOM Institute DIFFER, Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster and ITER-NL, PO Box 1207, 3430 BE Nieuwegein (Netherlands); Heemskerk, C.J.M.; Schoen, P.; Smedinga, D. [Heemskerk Innovative Technology, Noordwijk (Netherlands); Boode, A.H. [University of Applied Sciences InHolland, Alkmaar (Netherlands); Hamilton, D.T. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France)

    2013-10-15

    Highlights: ► Remote Handling Study Centre: middleware system setup and modules built. ► Aligning to ITER RH Control System Layout: prototype of database, VR and simulator. ► OpenSplice DDS, ZeroC ICE messaging and object oriented middlewares reviewed. ► Windows network latency found problematic for semi-realtime control over the network. -- Abstract: Remote maintenance activities in ITER will be performed by a unique set of hardware systems, supported by an extensive software kit. A layer of middleware will manage and control a complex set of interconnections between teams of operators, hardware devices in various operating theatres, and databases managing tool and task logistics. The middleware is driven by constraints on amounts and timing of data like real-time control loops, camera images, and database access. The Remote Handling Study Centre (RHSC), located at FOM institute DIFFER, has a 4-operator work cell in an ITER relevant RH Control Room setup which connects to a virtual hot cell back-end. The centre is developing and testing flexible integration of the Control Room components, resulting in proof-of-concept tests of this middleware layer. SW components studied include generic human-machine interface software, a prototype of a RH operations management system, and a distributed virtual reality system supporting multi-screen, multi-actor, and multiple independent views. Real-time rigid body dynamics and contact interaction simulation software supports simulation of structural deformation, “augmented reality” operations and operator training. The paper presents generic requirements and conceptual design of middleware components and Operations Management System in the context of a RH Control Room work cell. The simulation software is analyzed for real-time performance and it is argued that it is critical for middleware to have complete control over the physical network to be able to guarantee bandwidth and latency to the components.

  19. Uranium resource evaluation project quality assurance evaluation

    International Nuclear Information System (INIS)

    Grimes, J.G.

    1981-01-01

    This evaluation was conducted over an eight-month period from February 4 through October 1, 1980. During this time, field sampling was suspended for an indefinite time period while the National Uranium Resource Evaluation (NURE) Program underwent restructuring. In addition, the Uranium Resource Evaluation (URE) Project archives are being restructured. Since it is difficult to evaluate quality assurance needs of a program that is undergoing drastic change and because sections of the evaluation were well along before these changes were announced, this evaluation reflects the situation as it was during February 1980. The following quality assurance related programs are continuing to date: (1) periodic checks of field sampling procedures by the Supervising Field Geologist and the Director of Field Operations; (2) verification of field form information and laboratory analytical data verification for all geochemical surveys; (3) URE Project laboratory quality control program (all elements routinely analyzed); and (4) Ames interlaboratory quality control program (uranium only). UCC-ND was given the responsibility of conducting a Hydrogeochemical and Stream Sediment Reconnaissance (HSSR) survey in the Central United States (Illinois, Indiana, Iowa, Kansas, Michigan, Minnesota, Nebraska, North Dakota, Oklahoma, Texas, South Dakota, and Wisconsin). During 1979 and 1980, 13 detailed surveys were conducted by the URE Project in the Central and Western United States to characterize the hydrogeochemistry, stream sediment geochemistry, and/or radiometric patterns of known or potential uranium occurrences. Beginning in 1980, the HSSR surveys were modified to the Regional Hydrogeochemical and Stream Sediment (RHSS) surveys

  20. [Quality Management and Quality Specifications of Laboratory Tests in Clinical Studies--Challenges in Pre-Analytical Processes in Clinical Laboratories].

    Science.gov (United States)

    Ishibashi, Midori

    2015-01-01

    The cost, speed, and quality are the three important factors recently indicated by the Ministry of Health, Labour and Welfare (MHLW) for the purpose of accelerating clinical studies. Based on this background, the importance of laboratory tests is increasing, especially in the evaluation of clinical study participants' entry and safety, and drug efficacy. To assure the quality of laboratory tests, providing high-quality laboratory tests is mandatory. For providing adequate quality assurance in laboratory tests, quality control in the three fields of pre-analytical, analytical, and post-analytical processes is extremely important. There are, however, no detailed written requirements concerning specimen collection, handling, preparation, storage, and shipping. Most laboratory tests for clinical studies are performed onsite in a local laboratory; however, a part of laboratory tests is done in offsite central laboratories after specimen shipping. As factors affecting laboratory tests, individual and inter-individual variations are well-known. Besides these factors, standardizing the factors of specimen collection, handling, preparation, storage, and shipping, may improve and maintain the high quality of clinical studies in general. Furthermore, the analytical method, units, and reference interval are also important factors. It is concluded that, to overcome the problems derived from pre-analytical processes, it is necessary to standardize specimen handling in a broad sense.

  1. Conceptual design of CFETR divertor remote handling compatible structure

    International Nuclear Information System (INIS)

    Dai, Huaichu; Yao, Damao; Cao, Lei; Zhou, Zibo; Li, Lei

    2016-01-01

    Highlights: • Conceptual design for the CFETR divertor have been proposed, especially the divertor remote handling compatible structure. • The degrees of freedom of the divertor are analyzed in order to validate the design the divertor supports structure. • Besides the ITER-like scheme, a new scheme for the divertor remote handling compatible supports is proposed, that is the rack and pinion mechanism. • The installation/removel process is verified through simulation in Delmia in order to check design quality for remote handling requirements. - Abstract: Divertor is one of key components of tokamak fusion reactor. The CFETR is China Fusion Engineering Test Reactor. Its divertor will expose to tritium environment and neutron radiation. Materials of the divertor will be radioactived, and cannot be handled by personnel directly. To develop structure which compatible with robots handle for installation, maintenance and removing is required. This paper introduces a conceptual design of CFETR divertor module which compatible with remote handling end-effectors. The divertor module is confined by inner and outer support. The inner support is only confined divertor module radial, toroidal and vertical moving freedom degrees, but not confined rotating freedom degrees. The outer support is the structure that can confine rotating freedom degrees and should also be compatible with remote handling end-effectors.

  2. Conceptual design of CFETR divertor remote handling compatible structure

    Energy Technology Data Exchange (ETDEWEB)

    Dai, Huaichu, E-mail: yaodm@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); University of Science and Technology of China, Hefei (China); Yao, Damao; Cao, Lei; Zhou, Zibo; Li, Lei [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2016-11-15

    Highlights: • Conceptual design for the CFETR divertor have been proposed, especially the divertor remote handling compatible structure. • The degrees of freedom of the divertor are analyzed in order to validate the design the divertor supports structure. • Besides the ITER-like scheme, a new scheme for the divertor remote handling compatible supports is proposed, that is the rack and pinion mechanism. • The installation/removel process is verified through simulation in Delmia in order to check design quality for remote handling requirements. - Abstract: Divertor is one of key components of tokamak fusion reactor. The CFETR is China Fusion Engineering Test Reactor. Its divertor will expose to tritium environment and neutron radiation. Materials of the divertor will be radioactived, and cannot be handled by personnel directly. To develop structure which compatible with robots handle for installation, maintenance and removing is required. This paper introduces a conceptual design of CFETR divertor module which compatible with remote handling end-effectors. The divertor module is confined by inner and outer support. The inner support is only confined divertor module radial, toroidal and vertical moving freedom degrees, but not confined rotating freedom degrees. The outer support is the structure that can confine rotating freedom degrees and should also be compatible with remote handling end-effectors.

  3. In vitro evaluation of gaseous microemboli handling of cardiopulmonary bypass circuits with and without integrated arterial line filters.

    Science.gov (United States)

    Liu, Saifei; Newland, Richard F; Tully, Phillip J; Tuble, Sigrid C; Baker, Robert A

    2011-09-01

    The delivery of gaseous microemboli (GME) by the cardiopulmonary bypass circuit should be minimized whenever possible. Innovations in components, such as the integration of arterial line filter (ALF) and ALFs with reduced priming volumes, have provided clinicians with circuit design options. However, before adopting these components clinically, their GME handling ability should be assessed. This study aims to compare the GME handling ability of different oxygenator/ALF combinations with our currently utilized combination. Five commercially available oxygenator/ALF combinations were evaluated in vitro: Terumo Capiox SX25RX and Dideco D734 (SX/D734),Terumo Capiox RX25R and AF125 (RX/AF125), Terumo FX25R (FX), Sorin Synthesis with 102 microm reservoir filter (SYN102), and Sorin Synthesis with 40 microm reservoir filter (SYN40). GME handling was studied by introducing air into the venous return at 100 mL/min for 60 seconds under two flow/ pressure combinations: 3.5 L/min, 150 mmHg and 5 L/min, 200 mmHg. Emboli were measured at three positions in the circuit using the Emboli Detection and Classification (EDAC) Quantifier and analyzed with the General Linear Model. All circuits significantly reduced GME. The SX/D734 and SYN40 circuits were most efficient in GME removal whilst the SYN102 handled embolic load (count and volume) least efficiently (p circuits (p circuits (p circuits to handle GME. Venous reservoir design influenced the overall GME handling ability. GME removal was less efficient at higher flow and pressure, and for smaller sized emboli. The clinical significance of reducing GME requires further investigation.

  4. Neonates do not need to be handled for radiographs

    International Nuclear Information System (INIS)

    Slade, Dawn; Alfaham, Mazin; Davis, Peter; Tuthill, David; Harrison, Sara; Morris, Susan; Guildea, Zoe

    2005-01-01

    The handling of sick neonates may have detrimental effects such as hypoxia or bradycardia. Such handling is inevitable due to the frequent need for practical procedures; however, minimising handling reduces these adverse events and may improve outcome. Radiography is one of the commonest procedures performed on neonates. Usually the infant is lifted and placed onto the radiographic cassette; however, modern incubators often incorporate a tray beneath the mattress in which the radiographic cassette can be placed without the need to disturb the infant. To compare the quality of chest radiographs taken using the standard direct contact method, with those taken using the under-tray technique. A series of chest radiographs taken over a 21-month period were analysed independently by two consultant paediatric radiologists unaware of the radiographic details. The position of the radiograph, i.e. direct contact or under-tray, was determined by the radiographer. Radiographic quality was scored on the following features: exposure, blurring, rotation, cut-off or coning, and side markers. A subjective score was also included. The results from each radiologist were analysed separately. Seventy chest radiographs were analysed - 25 standard method, 45 under-tray. A statistically significant advantage for the under-tray method was seen on two analyses - radiologist 1 for exposure, and radiologist 2 for cut-off. No other significant differences were noted. There were no differences in the infants' weights or radiation exposure. The under-tray method for taking radiographs may produce films of at least equivalent quality to the standard method. Since the standard method involves handling with potential desaturation and bradycardia, this technique should cease. (orig.)

  5. Fuel handling machine and auxiliary systems for a fuel handling cell

    International Nuclear Information System (INIS)

    Suikki, M.

    2013-10-01

    This working report is an update for as well as a supplement to an earlier fuel handling machine design (Kukkola and Roennqvist 2006). A focus in the earlier design proposal was primarily on the selection of a mechanical structure and operating principle for the fuel handling machine. This report introduces not only a fuel handling machine design but also auxiliary fuel handling cell equipment and its operation. An objective of the design work was to verify the operating principles of and space allocations for fuel handling cell equipment. The fuel handling machine is a remote controlled apparatus capable of handling intensely radiating fuel assemblies in the fuel handling cell of an encapsulation plant. The fuel handling cell is air tight space radiation-shielded with massive concrete walls. The fuel handling machine is based on a bridge crane capable of traveling in the handling cell along wall tracks. The bridge crane has its carriage provided with a carousel type turntable having mounted thereon both fixed and telescopic masts. The fixed mast has a gripper movable on linear guides for the transfer of fuel assemblies. The telescopic mast has a manipulator arm capable of maneuvering equipment present in the fuel handling cell, as well as conducting necessary maintenance and cleaning operations or rectifying possible fault conditions. The auxiliary fuel handling cell systems consist of several subsystems. The subsystems include a service manipulator, a tool carrier for manipulators, a material hatch, assisting winches, a vacuum cleaner, as well as a hose reel. With the exception of the vacuum cleaner, the devices included in the fuel handling cell's auxiliary system are only used when the actual encapsulation process is not ongoing. The malfunctions of mechanisms or actuators responsible for the motion actions of a fuel handling machine preclude in a worst case scenario the bringing of the fuel handling cell and related systems to a condition appropriate for

  6. Fuel handling machine and auxiliary systems for a fuel handling cell

    Energy Technology Data Exchange (ETDEWEB)

    Suikki, M. [Optimik Oy, Turku (Finland)

    2013-10-15

    This working report is an update for as well as a supplement to an earlier fuel handling machine design (Kukkola and Roennqvist 2006). A focus in the earlier design proposal was primarily on the selection of a mechanical structure and operating principle for the fuel handling machine. This report introduces not only a fuel handling machine design but also auxiliary fuel handling cell equipment and its operation. An objective of the design work was to verify the operating principles of and space allocations for fuel handling cell equipment. The fuel handling machine is a remote controlled apparatus capable of handling intensely radiating fuel assemblies in the fuel handling cell of an encapsulation plant. The fuel handling cell is air tight space radiation-shielded with massive concrete walls. The fuel handling machine is based on a bridge crane capable of traveling in the handling cell along wall tracks. The bridge crane has its carriage provided with a carousel type turntable having mounted thereon both fixed and telescopic masts. The fixed mast has a gripper movable on linear guides for the transfer of fuel assemblies. The telescopic mast has a manipulator arm capable of maneuvering equipment present in the fuel handling cell, as well as conducting necessary maintenance and cleaning operations or rectifying possible fault conditions. The auxiliary fuel handling cell systems consist of several subsystems. The subsystems include a service manipulator, a tool carrier for manipulators, a material hatch, assisting winches, a vacuum cleaner, as well as a hose reel. With the exception of the vacuum cleaner, the devices included in the fuel handling cell's auxiliary system are only used when the actual encapsulation process is not ongoing. The malfunctions of mechanisms or actuators responsible for the motion actions of a fuel handling machine preclude in a worst case scenario the bringing of the fuel handling cell and related systems to a condition appropriate for

  7. Enhanced wood fuel handling: market and design studies

    Energy Technology Data Exchange (ETDEWEB)

    Landen, R.; Rippengal, R.; Redman, A.N.

    1997-09-01

    This report examines the potential for the manufacture and sale of novel wood fuel handling systems as a means of addressing users' concerns regarding current capital costs and potential high labour costs of non-automated systems. The report considers fuel handling technology that is basically appropriate for wood-fired heating systems of between c.100kW and c.1MW maximum continuous rating. This report details work done by the project collaborators in order to: (1) assess the current status of wood fuel handling technology; (2) evaluate the market appetite for improved wood fuel handling technology; (3) derive capital costs which are acceptable to customers; (4) review design options; and (5) select one or more design options worthy of further development. The current status of wood fuel handling technology is determined, and some basic modelling to give guidance on acceptable capital costs of 100-1000kW wood fuel handling systems is undertaken. (author)

  8. Study over problems related to fuel and ash handling systems; Probleminventering braensle- och askhantering

    Energy Technology Data Exchange (ETDEWEB)

    Njurell, Rolf; Wikman, Karin [AaF-Energi och Miljoe AB, Stockhom (Sweden)

    2003-10-01

    There have been a lot of problems related to fuel and ash handling systems since the combustion of different types of biofuels started in the 70s. Many measures have been taken to solve some of the problems, but others have become part of the daily work. The purpose of this study has been to do a compilation of the fuel and ash handling problems that exist at different types of heat and power plants. The study over problems related to fuel and ash handling systems has been carried out through a questionnaire via the Internet. Directors at about 150 energy production plants were contacted by phone or e-mail in the beginning of the project and asked to participate in the study. 72 of these plants accepted to fill in the questionnaire. After several reminders by e-mails and phone calls there were in the end 32 plants that completed the form. Together they reported about 25 problems related to fuel handling and 27 problems related to ash handling. In general each of the plants reported one problem of each kind. Even if the material from the questionnaire is not enough to make statistical analysis a few conclusions can be made about the most common problems, the cause of the problems and where they appear. Fuel handling problems that occur at several plants are stoppage in the conveying equipment, bridging in the boiler silo or the tipping bunker and problems with the sieve for separation. The distribution of the fuel handling problems is almost equal for all equipment parts (receiving, separation, transport etc.). For the ash handling systems problems with transport of dry bottom ash dominate, followed by and the moistening of fly ash and transport of wet bottom ash. Most of the problems related to fuel handling are caused by the fuel quality. For example several plants have reported that bark is a fuel that is hard to handle. Nevertheless the quality for a specific fuel is not always bad when it is delivered to the plant but the fuel quality might change during

  9. Bone biopsy needles. Mechanical properties, needle design and specimen quality

    International Nuclear Information System (INIS)

    Keulers, Annika; Penzkofer, T.; Cunha-Cruz, V.C.; Bruners, P.; Helmholtz Inst. fuer biomedizinische Technik, Aachen; Braunschweig, T.; Schmitz-Rode, T.; Mahnken, A.; Helmholtz Inst. fuer biomedizinische Technik, Aachen

    2011-01-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. Materials and Methods: In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Results: Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Conclusion: Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. (orig.)

  10. How the NWC handles software as product

    Energy Technology Data Exchange (ETDEWEB)

    Vinson, D.

    1997-11-01

    This tutorial provides a hands-on view of how the Nuclear Weapons Complex project should be handling (or planning to handle) software as a product in response to Engineering Procedure 401099. The SQAS has published the document SQAS96-002, Guidelines for NWC Processes for Handling Software Product, that will be the basis for the tutorial. The primary scope of the tutorial is on software products that result from weapons and weapons-related projects, although the information presented is applicable to many software projects. Processes that involve the exchange, review, or evaluation of software product between or among NWC sites, DOE, and external customers will be described.

  11. Quality dimensions in health evaluation: manager's conceptions.

    Science.gov (United States)

    Bosi, Maria Lúcia Magalhães; Pontes, Ricardo José Soares; Vasconcelos, Suziana Martins de

    2010-04-01

    To understand manager's perceptions and experiences in regards to qualitative evaluations in basic health care. A qualitative study, based on the critical interpretive approach, was performed in 2006, in the city of Fortaleza, Northeastern Brazil. The sample consisted of the group responsible for planning basic health care at the state level. In order to obtain the empirical data, the focus group technique was utilized. Two central themes emerged concerning the perceptions about quality and the dimensions of quality employed in health evaluations, which were revealed in distinct ways. The concepts of quality evaluation and qualitative evaluation did not appear clearly understood, confusing qualitative evaluation with formal quality evaluations. Likewise, the inherent multidimensionality of quality was not recognized. Despite the criticism expressed by the participants regarding the improper quantification of certain dimensions, the necessary technical skills and understanding were not observed for the approach to include the distinct dimensions of quality in the evaluation process. The conceptions of managers responsible for the planning of basic health care at the state level revealed an important disassociation from the premises of qualitative evaluation, especially those evaluations oriented by the fourth generation approach. Therefore, the model adopted by these actors for the evaluation of program and service quality did not consider their multidimensionality.

  12. Measuring quality of care: considering conceptual approaches to quality indicator development and evaluation.

    Science.gov (United States)

    Stelfox, Henry T; Straus, Sharon E

    2013-12-01

    In this article, we describe one approach for developing and evaluating quality indicators. We focus on describing different conceptual approaches to quality indicator development, review one approach for developing quality indicators, outline how to evaluate quality indicators once developed, and discuss quality indicator maintenance. The key steps for developing quality indicators include specifying a clear goal for the indicators; using methodologies to incorporate evidence, expertise, and patient perspectives; and considering contextual factors and logistics of implementation. The Strategic Framework Board and the National Quality Measure Clearinghouse have developed criteria for evaluating quality indicators that complement traditional psychometric evaluations. Optimal strategies for quality indicator maintenance and dissemination have not been determined, but experiences with clinical guideline maintenance may be informative. For quality indicators to effectively guide quality improvement efforts, they must be developed, evaluated, maintained, and implemented using rigorous evidence-informed practices. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Evaluation of imaging quality for flat-panel detector based low dose C-arm CT system

    International Nuclear Information System (INIS)

    Seo, Chang-Woo; Cha, Bo Kyung; Jeon, Sungchae; Huh, Young

    2015-01-01

    The image quality associated with the extent of the angle of gantry rotation, the number of projection views, and the dose of X-ray radiation was investigated in flat-panel detector (FPD) based C-arm cone-beam computed tomography (CBCT) system for medical applications. A prototype CBCT system for the projection acquisition used the X-ray tube (A-132, Varian inc.) having rhenium-tungsten molybdenum target and flat panel a-Si X-ray detector (PaxScan 4030CB, Varian inc.) having a 397 x 298 mm active area with 388 μm pixel pitch and 1024 x 768 pixels in 2 by 2 binning mode. The performance comparison of X-ray imaging quality was carried out using the Feldkamp, Davis, and Kress (FDK) reconstruction algorithm between different conditions of projection acquisition. In this work, head-and-dental (75 kVp/20 mA) and chest (90 kVp/25 mA) phantoms were used to evaluate the image quality. The 361 (30 fps x 12 s) projection data during 360 deg. gantry rotation with 1 deg. interval for the 3D reconstruction were acquired. Parke weighting function were applied to handle redundant data and improve the reconstructed image quality in a mobile C-arm system with limited rotation angles. The reconstructed 3D images were investigated for comparison of qualitative image quality in terms of scan protocols (projection views, rotation angles and exposure dose). Furthermore, the performance evaluation in image quality will be investigated regarding X-ray dose and limited projection data for a FPD based mobile C-arm CBCT system. (authors)

  14. Certification plan transuranic waste: Hazardous Waste Handling Facility

    International Nuclear Information System (INIS)

    1992-06-01

    The purpose of this plan is to describe the organization and methodology for the certification of transuranic (TRU) waste handled in the Hazardous Waste Handling Facility at Lawrence Berkeley Laboratory (LBL). The plan incorporates the applicable elements of waste reduction, which include both up-front minimization and end-product treatment to reduce the volume and toxicity of the waste; segregation of the waste as it applies to certification; an executive summary of the Quality Assurance Implementing Management Plan (QAIMP) for the HWBF; and a list of the current and planned implementing procedures used in waste certification

  15. About brachytherapy for the handling of cancer

    International Nuclear Information System (INIS)

    Campos, Tarcisio P.R.; Silva, Nilton O.; Damaso, Renato S.; Costa, Helder R.; Borges, Paulo H.R.; Mendes, Bruno M.

    2000-01-01

    The technique of brachytherapy is argued in this article. The 'hardware' and 'necessary software' for the handling are summarily presented. Being the macro-dosimetry an important stage in the radiation therapy procedure, a simplified method of doses evaluation in conventional brachytherapy is presented. In an illustrative form, isodoses of a three-dimensional distribution of linear sources are drawn on a digitalized X-ray picture, exemplifying the handling of breast brachytherapy by sources of iridium

  16. Multicriteria Evaluation of Product Quality

    OpenAIRE

    Pabedinskaitė, Arnoldina; Vitkauskas, Romualdas

    2009-01-01

    Product quality assessment is a complex task. The aim of this paper is to analyse the concepts of quality, different quality management models and their interaction with knowledge management models and the presented criteria system for assessing product quality. Moreover, multicriteria methods and their applicability to assessment of the product quality are analysed. On the basis of group of the product quality criteria and using the multicriteria evaluation methods, the quality of the produc...

  17. Evaluating the impact of handling and logger attachment on foraging parameters and physiology in southern rockhopper penguins.

    Directory of Open Access Journals (Sweden)

    Katrin Ludynia

    Full Text Available Logger technology has revolutionised our knowledge of the behaviour and physiology of free-living animals but handling and logger attachments may have negative effects on the behaviour of the animals and their welfare. We studied southern rockhopper penguin (Eudyptes chrysocome females during the guard stage in three consecutive breeding seasons (2008/09-2010/11 to evaluate the effects of handling and logger attachment on foraging trip duration, dive behaviour and physiological parameters. Smaller dive loggers (TDRs were used in 2010/11 for comparison to larger GPS data loggers used in all three seasons and we included two categories of control birds: handled controls and PIT control birds that were previously marked with passive integrative transponders (PITs, but which had not been handled during this study. Increased foraging trip duration was only observed in GPS birds during 2010/11, the breeding season in which we also found GPS birds foraging further away from the colony and travelling longer distances. Compared to previous breeding seasons, 2010/11 may have been a period with less favourable environmental conditions, which would enhance the impact of logger attachments. A comparison between GPS and TDR birds showed a significant difference in dive depth frequencies with birds carrying larger GPS data loggers diving shallower. Mean and maximum dive depths were similar between GPS and TDR birds. We measured little impact of logger attachments on physiological parameters (corticosterone, protein, triglyceride levels and leucocyte counts. Overall, handling and short-term logger attachments (1-3 days showed limited impact on the behaviour and physiology of the birds but care must be taken with the size of data loggers on diving seabirds. Increased drag may alter their diving behaviour substantially, thus constraining them in their ability to catch prey. Results obtained in this study indicate that data recorded may also not represent their

  18. Not Just Another Evaluation: A Comparative Study of Four Educational Quality Projects at Swedish Universities

    Science.gov (United States)

    Karlsson, Sara; Fogelberg, Karin; Kettis, Åsa; Lindgren, Stefan; Sandoff, Mette; Geschwind, Lars

    2014-01-01

    In this study, four recent self-initiated educational quality projects at Swedish universities are compared and analyzed. The article focuses on how the universities have handled the tension between external demands and internal norms. The aim is to contribute to an improved understanding of quality management in contemporary universities. On the…

  19. Process perspective on image quality evaluation

    Science.gov (United States)

    Leisti, Tuomas; Halonen, Raisa; Kokkonen, Anna; Weckman, Hanna; Mettänen, Marja; Lensu, Lasse; Ritala, Risto; Oittinen, Pirkko; Nyman, Göte

    2008-01-01

    The psychological complexity of multivariate image quality evaluation makes it difficult to develop general image quality metrics. Quality evaluation includes several mental processes and ignoring these processes and the use of a few test images can lead to biased results. By using a qualitative/quantitative (Interpretation Based Quality, IBQ) methodology, we examined the process of pair-wise comparison in a setting, where the quality of the images printed by laser printer on different paper grades was evaluated. Test image consisted of a picture of a table covered with several objects. Three other images were also used, photographs of a woman, cityscape and countryside. In addition to the pair-wise comparisons, observers (N=10) were interviewed about the subjective quality attributes they used in making their quality decisions. An examination of the individual pair-wise comparisons revealed serious inconsistencies in observers' evaluations on the test image content, but not on other contexts. The qualitative analysis showed that this inconsistency was due to the observers' focus of attention. The lack of easily recognizable context in the test image may have contributed to this inconsistency. To obtain reliable knowledge of the effect of image context or attention on subjective image quality, a qualitative methodology is needed.

  20. Examples of remote handling of irradiated fuel assemblies in Germany

    International Nuclear Information System (INIS)

    Peehs, M.; Knecht, K.

    1999-01-01

    Examples for the remote handling of irradiated fuel in Germany are presented in the following areas: - fuel assembling pool service activities; - early encapsulation of spent fuel in the pool of a nuclear power plant (NPP) at the end of the wet storage period. All development in remote fuel assembly handling envisages minimization of the radioactive dose applied to the operating staff. In the service area a further key objective for applying advanced methods is to perform the work faster and at a higher quality standard. The early encapsulation is a new technology to provide the final packaging of spent fuel already in the pool of a NPP to ensure reliable handling for all further back end processes. (author)

  1. Enbridge system : crude types, transportation and handling systems

    Energy Technology Data Exchange (ETDEWEB)

    Anand, A. [Enbridge Corp., Edmonton, AB (Canada)

    2009-07-01

    The supply of crude oil from the Western Canada Sedimentary Basin is expected to increase by approximately 2.1 million barrels per day by 2015. The crudes that Enbridge handles range from 19 API to 40 API and 0.1 per cent sulphur to 4.7 per cent sulphur. The diverse supply of crude oil that the Enbridge system handles includes conventional heavy, synthetic heavy, heavy high tan, heavy low residual, medium, light sour, heavy sour, light sweet, light sweet synthetic, condensate and olefinic crudes. This presentation discussed Enbridge's plans for infrastructure expansion, crude types and quality assurance program. The company's infrastructure plans include the expansion of regional pipelines to bring more supplies to the mainline; expansion of the mainline capacity to existing markets; and providing pipeline access to new markets. Merchant storage terminals will be provided in some locations. The quality of various crude types will be maintained through judicious sequencing and tank bottoms crossings. tabs., figs.

  2. A multi-component patient-handling intervention improves attitudes and behaviors for safe patient handling and reduces aggression experienced by nursing staff

    DEFF Research Database (Denmark)

    Risør, Bettina Wulff; Casper, Sven Dalgas; Andersen, Lars L.

    2017-01-01

    This study evaluated an intervention for patient-handling equipment aimed to improve nursing staffs' use of patient handling equipment and improve their general health, reduce musculoskeletal problems, aggressive episodes, days of absence and work-related accidents. As a controlled before......-after study, questionnaire data were collected at baseline and 12-month follow-up among nursing staff at intervention and control wards at two hospitals. At 12-month follow-up, the intervention group had more positive attitudes towards patient-handling equipment and increased use of specific patient......-handling equipment. In addition, a lower proportion of nursing staff in the intervention group had experienced physically aggressive episodes. No significant change was observed in general health status, musculoskeletal problems, days of absence or work-related accidents. The intervention resulted in more positive...

  3. Ergonomics of disposable handles for minimally invasive surgery.

    Science.gov (United States)

    Büchel, D; Mårvik, R; Hallabrin, B; Matern, U

    2010-05-01

    The ergonomic deficiencies of currently available minimally invasive surgery (MIS) instrument handles have been addressed in many studies. In this study, a new ergonomic pistol handle concept, realized as a prototype, and two disposable ring handles were investigated according to ergonomic properties set by new European standards. In this study, 25 volunteers performed four practical tasks to evaluate the ergonomics of the handles used in standard operating procedures (e.g., measuring a suture and cutting to length, precise maneuvering and targeting, and dissection of a gallbladder). Moreover, 20 participants underwent electromyography (EMG) tests to measure the muscle strain they experienced while carrying out the basic functions (grasp, rotate, and maneuver) in the x, y, and z axes. The data measured included the number of errors, the time required for task completion, perception of pressure areas, and EMG data. The values for usability in the test were effectiveness, efficiency, and user satisfaction. Surveys relating to the subjective rating were completed after each task for each of the three handles tested. Each handle except the new prototype caused pressure areas and pain. Extreme differences in muscle strain could not be observed for any of the three handles. Experienced surgeons worked more quickly with the prototype when measuring and cutting a suture (approximately 20%) and during precise maneuvering and targeting (approximately 20%). On the other hand, they completed the dissection task faster with the handle manufactured by Ethicon. Fewer errors were made with the prototype in dissection of the gallbladder. In contrast to the handles available on the market, the prototype was always rated as positive by the volunteers in the subjective surveys. None of the handles could fulfil all of the requirements with top scores. Each handle had its advantages and disadvantages. In contrast to the ring handles, the volunteers could fulfil most of the tasks more

  4. Siting Study for the Remote-Handled Low-Level Waste Disposal Project

    Energy Technology Data Exchange (ETDEWEB)

    Lisa Harvego; Joan Connolly; Lance Peterson; Brennon Orr; Bob Starr

    2010-10-01

    The U.S. Department of Energy has identified a mission need for continued disposal capacity for remote-handled low-level waste (LLW) generated at the Idaho National Laboratory (INL). An alternatives analysis that was conducted to evaluate strategies to achieve this mission need identified two broad options for disposal of INL generated remote-handled LLW: (1) offsite disposal and (2) onsite disposal. The purpose of this study is to identify candidate sites or locations within INL boundaries for the alternative of an onsite remote handled LLW disposal facility and recommend the highest-ranked locations for consideration in the National Environmental Policy Act process. The study implements an evaluation based on consideration of five key elements: (1) regulations, (2) key assumptions, (3) conceptual design, (4) facility performance, and (5) previous INL siting study criteria, and uses a five-step process to identify, screen, evaluate, score, and rank 34 separate sites located across INL. The result of the evaluation is identification of two recommended alternative locations for siting an onsite remote-handled LLW disposal facility. The two alternative locations that best meet the evaluation criteria are (1) near the Advanced Test Reactor Complex and (2) west of the Idaho Comprehensive Environmental Response, Compensation, and Liability Act Disposal Facility.

  5. QUALITY OF AN ACADEMIC STUDY PROGRAMME - EVALUATION MODEL

    Directory of Open Access Journals (Sweden)

    Mirna Macur

    2016-01-01

    Full Text Available Quality of an academic study programme is evaluated by many: employees (internal evaluation and by external evaluators: experts, agencies and organisations. Internal and external evaluation of an academic programme follow written structure that resembles on one of the quality models. We believe the quality models (mostly derived from EFQM excellence model don’t fit very well into non-profit activities, policies and programmes, because they are much more complex than environment, from which quality models derive from (for example assembly line. Quality of an academic study programme is very complex and understood differently by various stakeholders, so we present dimensional evaluation in the article. Dimensional evaluation, as opposed to component and holistic evaluation, is a form of analytical evaluation in which the quality of value of the evaluand is determined by looking at its performance on multiple dimensions of merit or evaluation criteria. First stakeholders of a study programme and their views, expectations and interests are presented, followed by evaluation criteria. They are both joined into the evaluation model revealing which evaluation criteria can and should be evaluated by which stakeholder. Main research questions are posed and research method for each dimension listed.

  6. Safety handling manual for high dose rate remote afterloading system

    International Nuclear Information System (INIS)

    1999-01-01

    This manual is mainly for safety handling of 192 Ir-RALS (remote afterloading system) of high dose rate and followings were presented: Procedure and document format for the RALS therapy and for handling of its radiation source with the purpose of prevention of human errors and unexpected accidents, Procedure for preventing errors occurring in the treatment schedule and operation, and Procedure and format necessary for newly introducing the system into a facility. Consistency was intended in the description with the quality assurance guideline for therapy with small sealed radiation sources made by JASTRO (Japan Society for Therapeutic Radiology and Oncology). Use of the old type 60 Co-RALS was pointed out to be a serious problem remained and its safety handling procedure was also presented. (K.H.)

  7. Redesign Handle Wheelbarrow Untuk Mengurangi Keluhan Musculoskeletal Menggunakan Metode Quality Function Deployment (QFD di Perkebunan Kelapa Sawit Bagan Jaya Kab. Indragiri Hilir, Riau

    Directory of Open Access Journals (Sweden)

    M. Gasali M

    2015-12-01

      Design Handle Wheelbarrow to Reduce Musculoskeletal Complaints Method Using Quality Function Deployment (QFD in Oil Palm Plantation Bagan Jaya District, Indragiri Hilir, Riau Abstract. Wheelbarrow is one means of conveyance of material, namely a wheelbarrow, wheelbarrow initially a conveyance which is very useful for people who transport activity plantation crops or also goods buildings, etc., when seen from the definition wheelbarrow is a means of transport that is driven by hand , has 1 piece wheels, and driven by an operator through the handle. In line with this has been a lot of developments done on the system and methods of support to facilitate all those activities. One of these tools is the wheelbarrow transport meterial (wheelbarrow. Handcart or wheelbarrow to haul awalnyamerupakan a very useful tool for people to do activities or also the transportation of farm goods and other buildings, performed percentile calculation result obtained by rounding length of 29.02 cm to 30 cm. so long hendle ergonomic design based anthropometric oil palm plantation workers is 30 cm, calculated from the point of welding, wheelbarrow hendle diameter of 3.03 cm, and width hendle 9, 04 cm with rounding to 9 cm. Results of the study after the redesign Wheelbarrow based Quality Function Deployment (QFD is to have the aspects of quality, ergonomics complete that is effective, convenient, safe, healthy, and efficient (ENASE. Musculoskeletal complaints plantation employees decreased by 31.79%.

  8. Nuclear fuel handling apparatus

    International Nuclear Information System (INIS)

    Andrea, C.; Dupen, C.F.G.; Noyes, R.C.

    1977-01-01

    A fuel handling machine for a liquid metal cooled nuclear reactor in which a retractable handling tube and gripper are lowered into the reactor to withdraw a spent fuel assembly into the handling tube. The handling tube containing the fuel assembly immersed in liquid sodium is then withdrawn completely from the reactor into the outer barrel of the handling machine. The machine is then used to transport the spent fuel assembly directly to a remotely located decay tank. The fuel handling machine includes a decay heat removal system which continuously removes heat from the interior of the handling tube and which is capable of operating at its full cooling capacity at all times. The handling tube is supported in the machine from an articulated joint which enables it to readily align itself with the correct position in the core. An emergency sodium supply is carried directly by the machine to provide make up in the event of a loss of sodium from the handling tube during transport to the decay tank. 5 claims, 32 drawing figures

  9. Spent nuclear fuel shipping cask handling capabilities of commercial light water reactors

    International Nuclear Information System (INIS)

    Daling, P.M.; Konzek, G.J.; Lezberg, A.J.; Votaw, E.F.; Collingham, M.I.

    1985-04-01

    This report describes an evaluation of the cask handling capabilities of those reactors which are operating or under construction. A computerized data base that includes cask handling information was developed with information from the literature and utility-supplied data. The capability of each plant to receive and handle existing spent fuel shipping casks was then evaluated. Modal fractions were then calculated based on the results of these evaluations and the quantities of spent fuel projected to be generated by commercial nuclear power plants through 1998. The results indicated that all plants are capable of receiving and handling truck casks. Up to 118 out of 130 reactors (91%) could potentially handle the larger and heavier rail casks if the maximum capability of each facility is utilized. Design and analysis efforts and physical modifications to some plants would be needed to achieve this high rail percentage. These modifications would be needed to satisfy regulatory requirements, increase lifting capabilities, develop rail access, or improve other deficiencies. The remaining 12 reactors were determined to be capable of handling only the smaller truck casks. The percentage of plants that could receive and handle rail casks in the near-term would be reduced to 64%. The primary reason for a plant to be judged incapable of handling rail casks in the near-term was a lack of rail access. The remaining 36% of the plants would be limited to truck shipments. The modal fraction calculations indicated that up to 93% of the spent fuel accumulated by 1998 could be received at federal storage or disposal facilities via rail (based on each plant's maximum capabilities). If the near-term cask handling capabilities are considered, the rail percentage is reduced to 62%

  10. Force Sensitive Handles and Capacitive Touch Sensor for Driving a Flexible Haptic-Based Immersive System

    OpenAIRE

    Covarrubias, Mario; Bordegoni, Monica; Cugini, Umberto

    2013-01-01

    In this article, we present an approach that uses both two force sensitive handles (FSH) and a flexible capacitive touch sensor (FCTS) to drive a haptic-based immersive system. The immersive system has been developed as part of a multimodal interface for product design. The haptic interface consists of a strip that can be used by product designers to evaluate the quality of a 3D virtual shape by using touch, vision and hearing and, also, to interactively change the shape of the virtual object...

  11. Review on Fuel Loading Process and Performance for Advanced Fuel Handling Equipment

    International Nuclear Information System (INIS)

    Chang, Sang-Gyoon; Lee, Dae-Hee; Kim, Young-Baik; Lee, Deuck-Soo

    2007-01-01

    The fuel loading process and the performance of the advanced fuel handling equipment for OPR 1000 (Optimized Power Plant) are analyzed and evaluated. The fuel handling equipment, which acts critical processes in the refueling outage, has been improved to reduce fuel handling time. The analysis of the fuel loading process can be a useful tool to improve the performance of the fuel handling equipment effectively. Some recommendations for further improvement are provided based on this study

  12. Image quality evaluation of full reference algorithm

    Science.gov (United States)

    He, Nannan; Xie, Kai; Li, Tong; Ye, Yushan

    2018-03-01

    Image quality evaluation is a classic research topic, the goal is to design the algorithm, given the subjective feelings consistent with the evaluation value. This paper mainly introduces several typical reference methods of Mean Squared Error(MSE), Peak Signal to Noise Rate(PSNR), Structural Similarity Image Metric(SSIM) and feature similarity(FSIM) of objective evaluation methods. The different evaluation methods are tested by Matlab, and the advantages and disadvantages of these methods are obtained by analyzing and comparing them.MSE and PSNR are simple, but they are not considered to introduce HVS characteristics into image quality evaluation. The evaluation result is not ideal. SSIM has a good correlation and simple calculation ,because it is considered to the human visual effect into image quality evaluation,However the SSIM method is based on a hypothesis,The evaluation result is limited. The FSIM method can be used for test of gray image and color image test, and the result is better. Experimental results show that the new image quality evaluation algorithm based on FSIM is more accurate.

  13. Quality measures for nurse practitioner practice evaluation.

    Science.gov (United States)

    Kleinpell, Ruth; Kapu, April N

    2017-08-01

    Evaluating the impact of nurse practitioner (NP) practice has become a priority area of focus for demonstrating outcomes. A number of quality measures are available to enable practice-specific evaluation of NP roles and initiatives. This article reviews sources of quality measures that can be used to facilitate quantifying the outcomes of NP practice as part of an overall evaluation agenda. National resources and published literature on NP quality measures were reviewed. Various resources and toolkits exist to assist NPs in identifying outcomes of practice using quality measures. The need to demonstrate outcomes of NP practice remains an ongoing priority area regardless of the clinical practice setting. A variety of sources of quality measures exist that can be used to showcase the effect of NP care. The use of quality measures can be effectively integrated into evaluation of NP role and NP-directed initiatives to demonstrate impact, and enhance the conduct of an NP outcomes assessment. The use of organizational, NP-specific, and national-related quality measures can help to showcase how NP care improves the quality, safety, and costs of health care. ©2017 American Association of Nurse Practitioners.

  14. Handling and transfer operations for partially-spent nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, J K [PUSPATI, Kuala Lumpur (Malaysia)

    1983-12-01

    This project involved the handling and transfer of partially-spent reactor fuel from the Oregon State University TRIGA Reactor in Corvallis, Oregon to Hanford Engineering Development Laboratory in Richland, Washington. The method of handling is dependent upon the burn-up history of the fuel elements. Legal constraints imposed by standing U.S. nuclear regulations determine the selection of transport containers, transportation procedures, physical security arrangements in transit and nuclear material accountability documentation. Results of in-house safety evaluations of the project determine the extent of involvement of pertinent nuclear regulatory authorities. The actual handling activities and actual radiation dose rates are also presented.

  15. CANDU-9/480-SEU fuel handling system assessment document

    International Nuclear Information System (INIS)

    Hwang, Jeong Ki; Jo, C. H.; Kim, H. M.; Morikawa, D. T.

    1996-11-01

    This report summarize the rationale for the CANDU 9 fuel handling system, and the design choices recommended for components of the system. Some of the design requirements applicable to the CANDU 9 480-SEU fuel handling design choices are described. These requirements imposed by the CANDU 9 project. And the design features for the key components of fuel handling system, such as the fuelling machine, the carriage, the new fuel transfer system and the irradiated fuel transfer system, are described. The carriage seismic load evaluations relevant to the design are contained in the appendices. The majority of the carriage components are acceptable, or will likely be acceptable with some redesign. The concept for the CANDU 9 fuel handling system is based on proven CANDU designs, or on improved CANDU technology. Although some development work must be done, the fuel handling concept is judged to be feasible for the CANDU 9 480-SEU reactor. (author). 2 refs

  16. Implications of Continuous Quality Improvement for Program Evaluation and Evaluators.

    Science.gov (United States)

    Mark, Melvin M.; Pines, Edward

    1995-01-01

    Explores the implications that continuous quality improvement (CQI) programs are likely to have for evaluation. CQI, often known as total quality management, offers a structured approach to the analysis of an organization's processes and improvement that should provide advantages to evaluators once they have gained experience with the approach.…

  17. CLASSIFICATION OF THE MGR WASTE HANDLING BUILDING ELECTRICAL SYSTEM

    International Nuclear Information System (INIS)

    S.E. Salzman

    1999-01-01

    The purpose of this analysis is to document the Quality Assurance (QA) classification of the Monitored Geologic Repository (MGR) waste handling building electrical system structures, systems and components (SSCs) performed by the MGR Safety Assurance Department. This analysis also provides the basis for revision of YMP/90-55Q, Q-List (YMP 1998). The Q-List identifies those MGR SSCs subject to the requirements of DOE/RW-0333P, ''Quality Assurance Requirements and Description'' (QARD) (DOE 1998)

  18. Reviewing reactor engineering and fuel handling

    International Nuclear Information System (INIS)

    1991-12-01

    Experience has shown that the better operating nuclear power plants have well defined and effectively administered policies and procedures for governing reactor engineering and fuel handling (RE and FH) activities. This document provides supplementary guidance to OSART experts for evaluating the RE and FH programmes and activities at a nuclear power plant and assessing their effectiveness and adequacy. It is in no way intended to conflict with existing regulations and rules, but rather to exemplify those characteristics and features that are desirable for an effective, well structured RE and FH programme. This supplementary guidance addresses those aspects of RE and FH activities that are required in order to ensure optimum core operation for a nuclear reactor without compromising the limits imposed by the design, safety considerations of the nuclear fuel. In the context of this document, reactor engineering refers to those activities associated with in-core fuel and reactivity management, whereas fuel handling refers to the movement, storage, control and accountability of unirradiated and irradiated fuel. The document comprises five main sections and several appendices. In Section 2 of this guide, the essential aspects of an effective RE and FH programme are discussed. In Section 3, the various types of documents and reference materials needed for the preparatory work and investigation are listed. In Section 4, specific guidelines for investigation of RE and FH programmes are presented. In Section 5, the essential attributes of an excellent RE and FH programme are listed. The supplementary guidance is concluded with a series of appendices exemplifying the various qualities and attributes of a sound, well defined RE and FH programme

  19. Effect of lowered oxygen in aquaculture on rainbow trout muscle quality investigated by a proteomic approach

    DEFF Research Database (Denmark)

    Wulff, Tune

    , this can help pinpointing which changes in the fish muscle are due to hypoxia and which are down to other stressors. This can aid the aquaculture industry when evaluating the type of stressors mostly affecting food quality, allowing an optimisation of rainbow trout handling accordingly....... it significantly reduces the quality of the major edible part of the fish. Fish in aquaculture are stressed by handling (e.g. sorting, crowding and transportation) prior to slaughter and it is well established that such stress leads to reduced textural quality of the fish. However, it is still unclear which...

  20. Quantifying the effect of editor-author relations on manuscript handling times.

    Science.gov (United States)

    Sarigöl, Emre; Garcia, David; Scholtes, Ingo; Schweitzer, Frank

    2017-01-01

    In this article we study to what extent the academic peer review process is influenced by social relations between the authors of a manuscript and the editor handling the manuscript. Taking the open access journal PlosOne as a case study, our analysis is based on a data set of more than 100,000 articles published between 2007 and 2015. Using available data on handling editor, submission and acceptance time of manuscripts, we study the question whether co-authorship relations between authors and the handling editor affect the manuscript handling time , i.e. the time taken between the submission and acceptance of a manuscript. Our analysis reveals (1) that editors handle papers co-authored by previous collaborators significantly more often than expected at random, and (2) that such prior co-author relations are significantly related to faster manuscript handling. Addressing the question whether these shorter manuscript handling times can be explained by the quality of publications, we study the number of citations and downloads which accepted papers eventually accumulate. Moreover, we consider the influence of additional (social) factors, such as the editor's experience, the topical similarity between authors and editors, as well as reciprocal citation relations between authors and editors. Our findings show that, even when correcting for other factors like time, experience, and performance, prior co-authorship relations have a large and significant influence on manuscript handling times, speeding up the editorial decision on average by 19 days.

  1. A physical workload index to evaluate a safe resident handling program for nursing home personnel.

    Science.gov (United States)

    Kurowski, Alicia; Buchholz, Bryan; Punnett, Laura

    2014-06-01

    The aim of this study was to obtain a comprehensive analysis of the physical workload of clinical staff in long-term care facilities, before and after a safe resident handling program (SRHP). Ergonomic exposures of health care workers include manual handling of patients and many non-neutral postures. A comprehensive assessment requires the integration of loads from these varied exposures into a single metric. The Postures, Activities, Tools, and Handling observational protocol, customized for health care, was used for direct observations of ergonomic exposures in clinical jobs at 12 nursing homes before the SRHP and 3, 12, 24, and 36 months afterward. Average compressive forces on the spine were estimated for observed combinations of body postures and manual handling and then weighted by frequencies of observed time for the combination. These values were summed to obtain a biomechanical index for nursing assistants and nurses across observation periods. The physical workload index (PWI) was much higher for nursing assistants than for nurses and decreased more after 3 years (-24% versus -2.5%). Specifically during resident handling, the PWI for nursing assistants decreased by 41% of baseline value. Spinal loading was higher for nursing assistants than for nurses in long-term care centers. Both job groups experienced reductions in physical loading from the SRHP, especially the nursing assistants and especially while resident handling. The PWI facilitates a comprehensive investigation of physical loading from both manual handling and non-neutral postures. It can be used in any work setting to identify high-risk tasks and determine whether reductions in one exposure are offset by increases in another.

  2. Building a framework for ergonomic research on laparoscopic instrument handles.

    Science.gov (United States)

    Li, Zheng; Wang, Guohui; Tan, Juan; Sun, Xulong; Lin, Hao; Zhu, Shaihong

    2016-06-01

    Laparoscopic surgery carries the advantage of minimal invasiveness, but ergonomic design of the instruments used has progressed slowly. Previous studies have demonstrated that the handle of laparoscopic instruments is vital for both surgical performance and surgeon's health. This review provides an overview of the sub-discipline of handle ergonomics, including an evaluation framework, objective and subjective assessment systems, data collection and statistical analyses. Furthermore, a framework for ergonomic research on laparoscopic instrument handles is proposed to standardize work on instrument design. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  3. Water quality relationships and evaluation using a new water quality index

    International Nuclear Information System (INIS)

    Said, A.; Stevens, D.; Sehlke, G.

    2002-01-01

    Water quality is dependent on a variety of measures, including dissolved oxygen, microbial contamination, turbidity, nutrients, temperature, pH, and other constituents. Determining relationships between water quality parameters can improve water quality assessment, and watershed management. In addition, these relationships can be very valuable in case of evaluating water quality in watersheds that have few water quality data. (author)

  4. Handling and transfer operations for partially-spent nuclear fuel

    International Nuclear Information System (INIS)

    Ibrahim, J.K.

    1983-01-01

    This project involved the handling and transfer of partially-spent reactor fuel from the Oregon State University TRIGA Reactor in Corvallis, Oregon to Hanford Engineering Development Laboratory in Richland, Washington. The method of handling is dependent upon the burn-up history of the fuel elements. Legal constraints imposed by standing U.S. nuclear regulations determine the selection of transport containers, transportation procedures, physical security arrangements in transit and nuclear material accountability documentation. Results of in-house safety evaluations of the project determine the extent of involvement of pertinent nuclear regulatory authorities. The actual handling activities and actual radiation dose rates are also presented (author)

  5. Handling of plutonium and transplutonium elements and radioprotection

    Energy Technology Data Exchange (ETDEWEB)

    Rebiffe, J [CEA Centre d' Etudes de Valduc, 21 - Is-sur-Tille (France)

    1976-01-01

    Individual and collective protection procedures in the handling of significant amounts of plutonium have been adopted for many years; they are founded on its properties. Monitoring and counting techniques make it possible to follow the conditions of these protection procedures seriously. Minor or major failures in protection have never resulted in serious consequences for the public or for workers. Such a result has been obtained thanks to the existence of collective and individual protection procedures, the quality of prevention and the availability of efficient emergency means. The keeping of careful prevention, cooperation of all proficiencies, added to a long standing experience make it possible to state that plutonium handling does not present any more danger than many other (industrial or not) human activities.

  6. Handling of plutonium and transplutonium elements and radioprotection

    International Nuclear Information System (INIS)

    Rebiffe, J.

    1976-01-01

    Individual and collective protection procedures in the handling of significant amounts of plutonium have been adopted for many years; they are founded on its properties. Monitoring and counting techniques make it possible to follow the conditions of these protection procedures seriously. Minor or major failures in protection have never resulted in serious consequences for the public or for workers. Such a result has been obtained thanks to the existence of collective and individual protection procedures, the quality of prevention and the availability of efficient emergency means. The keeping of careful prevention, co-operation of all proficiencies, added to a long standing experience make it possible to state that plutonium handling does not present any more danger than many other (industrial or not) human activities [fr

  7. Evaluation of quality of life in oncology clinic

    International Nuclear Information System (INIS)

    Jarema, A.; Marzecki, Z.

    1994-01-01

    In 18 patients with various malignancies the quality of life was evaluated with the use of the SF-36 questionnaire before and after radiotherapy. The quality of life was better among patients whose physical condition was better both before and after radiotherapy. The quality of life deteriorated after radiotherapy in patients whose physical status before treatment was evaluated as more serious. After the treatment the correlation was found between the global evaluation of quality of life and the intensity of pain and physical disability. However, both before and after radiotherapy the correlation was found between global quality of life and the severity of depression. The subjective estimation of quality of life by cancer patients did not correlate with the clinical evaluation of the severity of their state in doctor's opinion. (author)

  8. CLASSIFICATION OF THE MGR MUCK HANDLING SYSTEM

    International Nuclear Information System (INIS)

    R. Garrett

    1999-01-01

    The purpose of this analysis is to document the Quality Assurance (QA) classification of the Monitored Geologic Repository (MGR) muck handling system structures, systems and components (SSCs) performed by the MGR Safety Assurance Department. This analysis also provides the basis for revision of YMP/90-55Q, Q-List (YMP 1998). The Q-List identifies those MGR SSCs subject to the requirements of DOE/RW-0333P, ''Quality Assurance Requirements and Description (QARD) (DOE 1998). This QA classification incorporates the current MGR design and the results of the ''Preliminary Preclosure Design Basis Event Calculations for the Monitored Geologic Repository (CRWMS M and O 1998a)

  9. Fluorescence excitation-emission matrix (EEM) spectroscopy for rapid identification and quality evaluation of cell culture media components.

    Science.gov (United States)

    Li, Boyan; Ryan, Paul W; Shanahan, Michael; Leister, Kirk J; Ryder, Alan G

    2011-11-01

    The application of fluorescence excitation-emission matrix (EEM) spectroscopy to the quantitative analysis of complex, aqueous solutions of cell culture media components was investigated. These components, yeastolate, phytone, recombinant human insulin, eRDF basal medium, and four different chemically defined (CD) media, are used for the formulation of basal and feed media employed in the production of recombinant proteins using a Chinese Hamster Ovary (CHO) cell based process. The comprehensive analysis (either identification or quality assessment) of these materials using chromatographic methods is time consuming and expensive and is not suitable for high-throughput quality control. The use of EEM in conjunction with multiway chemometric methods provided a rapid, nondestructive analytical method suitable for the screening of large numbers of samples. Here we used multiway robust principal component analysis (MROBPCA) in conjunction with n-way partial least squares discriminant analysis (NPLS-DA) to develop a robust routine for both the identification and quality evaluation of these important cell culture materials. These methods are applicable to a wide range of complex mixtures because they do not rely on any predetermined compositional or property information, thus making them potentially very useful for sample handling, tracking, and quality assessment in biopharmaceutical industries.

  10. Monitoring and evaluating soil quality

    NARCIS (Netherlands)

    Bloem, J.; Schouten, A.J.; Sørensen, S.J.; Rutgers, M.; Werf, van der A.K.; Breure, A.M.

    2006-01-01

    This book provides a selection of microbiological methods that are already applied in regional or national soil quality monitoring programs. It is split into two parts: part one gives an overview of approaches to monitoring, evaluating and managing soil quality. Part two provides a selection of

  11. Can control banding be useful for the safe handling of nanomaterials? A systematic review

    Science.gov (United States)

    Eastlake, Adrienne; Zumwalde, Ralph; Geraci, Charles

    2016-06-01

    Control banding (CB) is a risk management strategy that has been used to identify and recommend exposure control measures to potentially hazardous substances for which toxicological information is limited. The application of CB and level of expertise required for implementation and management can differ depending on knowledge of the hazard potential, the likelihood of exposure, and the ability to verify the effectiveness of exposure control measures. A number of different strategies have been proposed for using CB in workplaces where exposure to engineered nanomaterials (ENMs) can occur. However, it is unclear if the use of CB can effectively reduce worker exposure to nanomaterials. A systematic review of studies was conducted to answer the question "can control banding be useful to ensure adequate controls for the safe handling of nanomaterials." A variety of databases were searched to identify relevant studies pertaining to CB. Database search terms included `control,' `hazard,' `exposure,' and `risk' banding as well as the use of these terms in the context of nanotechnology or nanomaterials. Other potentially relevant studies were identified during the review of articles obtained in the systematic review process. Identification of studies and the extraction of data were independently conducted by the reviewers. Quality of the studies was assessed using the methodological index for nonrandomized studies. The quality of the evidence was evaluated using grading of recommendations assessment, development and evaluation (GRADE). A total of 235 records were identified in the database search in which 70 records were determined to be eligible for full-text review. Only two studies were identified that met the inclusion criteria. These studies evaluated the application of the CB Nanotool in workplaces where ENMs were being handled. A total of 32 different nanomaterial handling activities were evaluated in these studies by comparing the recommended exposure controls using

  12. New handling systems as technical support for the working process. Part 6. Feeding devices

    Energy Technology Data Exchange (ETDEWEB)

    Becher, H; Burkhardt, R; Drexel, P; Graf, B; Krreis, W

    1982-03-01

    Social, technical and economic reasons require an enhanced application of handling systems such as industrial robots. Quality and efficiency of an industrial robot depends greatly on feeding devices, and the ARGE-HHS within its project new handling systems as a technical aid in the working process intends to analyze all feeding devices that are likely to be most suitable for advanced applications. Forty one feeding devices were developed, known devices were modified, adapted to different applications, and tested. A variety of feeding devices for most applications in the field of material handling is reported.

  13. Spent fuel cask handling at an operating nuclear power plant

    International Nuclear Information System (INIS)

    Pal, A.C.

    1988-01-01

    The importance of spent fuel handling at operating nuclear power plants cannot be overstated. Because of its highly radioactive nature, however, spent fuel must be handled in thick, lead-lined containers or casks. Thus, all casks for spent fuel handling are heavy loads by the US Nuclear Regulatory Commission's definition, and any load-drop must be evaluated for its potential to damage safety-related equipment. Nuclear Regulatory Guide NUREG-0612 prescribes the regulatory requirements of alternative heavy-load-handling methodologies such as (a) by providing cranes that meet the requirements of NUREG-0554, which shall be called the soft path, or (b) by providing protective devices at all postulated load-drop areas to prevent any damage to safety-related equipment, which shall be called the hard path. The work reported in this paper relates to cask handling at New York Power Authority's James A. FitzPatrick (JAF) plant

  14. Academic research groups: evaluation of their quality and quality of their evaluation

    Science.gov (United States)

    Berche, Bertrand; Holovatch, Yuri; Kenna, Ralph; Mryglod, Olesya

    2016-02-01

    In recent years, evaluation of the quality of academic research has become an increasingly important and influential business. It determines, often to a large extent, the amount of research funding flowing into universities and similar institutes from governmental agencies and it impacts upon academic careers. Policy makers are becoming increasingly reliant upon, and influenced by, the outcomes of such evaluations. In response, university managers are increasingly attracted to simple metrics as guides to the dynamics of the positions of their various institutions in league tables. However, these league tables are invariably drawn up by inexpert bodies such as newspapers and magazines, using arbitrary measures and criteria. Terms such as “critical mass” and “h-index” are bandied about without understanding of what they actually mean. Rather than accepting the rise and fall of universities, departments and individuals on a turbulent sea of arbitrary measures, we suggest it is incumbent upon the scientific community itself to clarify their nature. Here we report on recent attempts to do that by properly defining critical mass and showing how group size influences research quality. We also examine currently predominant metrics and show that these fail as reliable indicators of group research quality.

  15. Pacific Northwest Laboratory (PNL) spent fuel transportation and handling facility models

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, W.B.; Bower, J.C.; Burnett, R.A.; Engel, R.L.; Rolland, C.W.

    1979-09-01

    A spent fuel logistics study was conducted in support of the US DOE program to develop facilities for preparing spent unreprocessed fuel from commercial LWRs for geological storage. Two computerized logistics models were developed. The first one was the site evaluation model. Two studies of spent fuel handling facility and spent fuel disposal facility siting were completed; the first postulates a single spent fuel handling facility located at any of six DOE laboratory sites, while the second study examined siting strategies with the spent fuel repository relative to the spent fuel handling facility. A second model to conduct storage/handling facility simulations was developed. (DLC)

  16. Pacific Northwest Laboratory (PNL) spent fuel transportation and handling facility models

    International Nuclear Information System (INIS)

    Andrews, W.B.; Bower, J.C.; Burnett, R.A.; Engel, R.L.; Rolland, C.W.

    1979-09-01

    A spent fuel logistics study was conducted in support of the US DOE program to develop facilities for preparing spent unreprocessed fuel from commercial LWRs for geological storage. Two computerized logistics models were developed. The first one was the site evaluation model. Two studies of spent fuel handling facility and spent fuel disposal facility siting were completed; the first postulates a single spent fuel handling facility located at any of six DOE laboratory sites, while the second study examined siting strategies with the spent fuel repository relative to the spent fuel handling facility. A second model to conduct storage/handling facility simulations was developed

  17. Force Sensitive Handles and Capacitive Touch Sensor for Driving a Flexible Haptic-Based Immersive System

    Directory of Open Access Journals (Sweden)

    Umberto Cugini

    2013-10-01

    Full Text Available In this article, we present an approach that uses both two force sensitive handles (FSH and a flexible capacitive touch sensor (FCTS to drive a haptic-based immersive system. The immersive system has been developed as part of a multimodal interface for product design. The haptic interface consists of a strip that can be used by product designers to evaluate the quality of a 3D virtual shape by using touch, vision and hearing and, also, to interactively change the shape of the virtual object. Specifically, the user interacts with the FSH to move the virtual object and to appropriately position the haptic interface for retrieving the six degrees of freedom required for both manipulation and modification modalities. The FCTS allows the system to track the movement and position of the user’s fingers on the strip, which is used for rendering visual and sound feedback. Two evaluation experiments are described, which involve both the evaluation and the modification of a 3D shape. Results show that the use of the haptic strip for the evaluation of aesthetic shapes is effective and supports product designers in the appreciation of the aesthetic qualities of the shape.

  18. Force sensitive handles and capacitive touch sensor for driving a flexible haptic-based immersive system.

    Science.gov (United States)

    Covarrubias, Mario; Bordegoni, Monica; Cugini, Umberto

    2013-10-09

    In this article, we present an approach that uses both two force sensitive handles (FSH) and a flexible capacitive touch sensor (FCTS) to drive a haptic-based immersive system. The immersive system has been developed as part of a multimodal interface for product design. The haptic interface consists of a strip that can be used by product designers to evaluate the quality of a 3D virtual shape by using touch, vision and hearing and, also, to interactively change the shape of the virtual object. Specifically, the user interacts with the FSH to move the virtual object and to appropriately position the haptic interface for retrieving the six degrees of freedom required for both manipulation and modification modalities. The FCTS allows the system to track the movement and position of the user's fingers on the strip, which is used for rendering visual and sound feedback. Two evaluation experiments are described, which involve both the evaluation and the modification of a 3D shape. Results show that the use of the haptic strip for the evaluation of aesthetic shapes is effective and supports product designers in the appreciation of the aesthetic qualities of the shape.

  19. Economic evaluation of flying-qualities design criteria for a transport configured with relaxed static stability

    Science.gov (United States)

    Sliwa, S. M.

    1980-01-01

    Direct constrained parameter optimization was used to optimally size a medium range transport for minimum direct operating cost. Several stability and control constraints were varied to study the sensitivity of the configuration to specifying the unaugmented flying qualities of transports designed to take maximum advantage of relaxed static stability augmentation systems. Additionally, a number of handling qualities related design constants were studied with respect to their impact on the design.

  20. Uranium hexafluoride: A manual of good handling practices. Revision 7

    International Nuclear Information System (INIS)

    1995-01-01

    The United States Enrichment Corporation (USEC) is continuing the policy of the US Department of Energy (DOE) and its predecessor agencies in sharing with the nuclear industry their experience in the area of uranium hexafluoride (UF 6 ) shipping containers and handling procedures. The USEC has reviewed Revision 6 or ORO-651 and is issuing this new edition to assure that the document includes the most recent information on UF 6 handling procedures and reflects the policies of the USEC. This manual updates the material contained in earlier issues. It covers the essential aspects of UF 6 handling, cylinder filling and emptying, general principles of weighing and sampling, shipping, and the use of protective overpacks. The physical and chemical properties of UF 6 are also described. The procedures and systems described for safe handling of UF 6 presented in this document have been developed and evaluated during more than 40 years of handling vast quantities of UF 6 . With proper consideration for its nuclear properties, UF 6 may be safely handled in essentially the same manner as any other corrosive and/or toxic chemical

  1. SIMULATION OF DRIVER’S LOCOMOTIVE-HANDLING ACTIVITY USING THE THEORY OF FUZZY GRAPHS

    Directory of Open Access Journals (Sweden)

    T. V. Butko

    2015-03-01

    Full Text Available Purpose. The efficiency and safety of locomotive control improving is important and relevant scientific and practical problem. Every driver during the trains-handling bases on his experience and knowledge, that is why the compilation and detection the most efficient ways to control the locomotive-handling is one of the stages of measures development to reduce transportation costs. The purpose of this paper is a formalization process description of locomotive-handling and quality parameters determination of this process. Methodology. In order to achieve this goal the theory of fuzzy probabilistic graphs was used. Vertices of the graph correspond to the events start and end operations at train-handling. The graph arcs describe operations on train-handling. Graph consists of thirteen peaks corresponding to the main control actions of the engine-driver. The weighting factors of transitions between vertices are assigned by fuzzy numbers. Their values were obtained by expert estimates. Fuzzy probabilities and transition time are presented as numbers with trapezoidal membership function. Findings. Using successive merging of parallel arcs, loops and vertices elimination, the equivalent fuzzy graph of train-handling and the corresponding L-matrix were obtained. Equivalent graph takes into account separately activity of the driver during normal operation and during emergency situations. Originality. The theoretical foundations of describing process formalization in driver’s locomotive-handling activity were developed using the fuzzy probabilistic graph. The parameters characterizing the decision-making process of engineer were obtained. Practical value. With the resulting model it is possible to estimate the available reserves for the quality improvement of locomotive-handling. Reduction in the time for decision-making will lead to the approximation the current mode of control to the rational one and decrease costs of hauling operations. And reduction

  2. Closed-system drug-transfer devices plus safe handling of hazardous drugs versus safe handling alone for reducing exposure to infusional hazardous drugs in healthcare staff.

    Science.gov (United States)

    Gurusamy, Kurinchi Selvan; Best, Lawrence Mj; Tanguay, Cynthia; Lennan, Elaine; Korva, Mika; Bussières, Jean-François

    2018-03-27

    Occupational exposure to hazardous drugs can decrease fertility and result in miscarriages, stillbirths, and cancers in healthcare staff. Several recommended practices aim to reduce this exposure, including protective clothing, gloves, and biological safety cabinets ('safe handling'). There is significant uncertainty as to whether using closed-system drug-transfer devices (CSTD) in addition to safe handling decreases the contamination and risk of staff exposure to infusional hazardous drugs compared to safe handling alone. To assess the effects of closed-system drug-transfer of infusional hazardous drugs plus safe handling versus safe handling alone for reducing staff exposure to infusional hazardous drugs and risk of staff contamination. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, OSH-UPDATE, CINAHL, Science Citation Index Expanded, economic evaluation databases, the World Health Organization International Clinical Trials Registry Platform, and ClinicalTrials.gov to October 2017. We included comparative studies of any study design (irrespective of language, blinding, or publication status) that compared CSTD plus safe handling versus safe handling alone for infusional hazardous drugs. Two review authors independently identified trials and extracted data. We calculated the risk ratio (RR) and mean difference (MD) with 95% confidence intervals (CI) using both fixed-effect and random-effects models. We assessed risk of bias according to the risk of bias in non-randomised studies of interventions (ROBINS-I) tool, used an intracluster correlation coefficient of 0.10, and we assessed the quality of the evidence using GRADE. We included 23 observational cluster studies (358 hospitals) in this review. We did not find any randomised controlled trials or formal economic evaluations. In 21 studies, the people who used the intervention (CSTD plus safe handling) and control (safe handling alone) were pharmacists or pharmacy

  3. Quality Index Method - An objective tool for determination of sensory quality

    DEFF Research Database (Denmark)

    Hyldig, Grethe; Green-Petersen, Ditte

    2004-01-01

    Sensory evaluation is one of the most important methods for assessing freshness and quality in the fish sector and in fish-inspection services. Sensory methods performed in a proper way are a rapid and accurate tool providing unique information about food. Traditionally, sensory methods have been...... seen as a subjective assessment of quality. However, sensory methods can be turned into an objective tool. European fisheries research institutes have developed such a tool, by which sensory assessment is performed in a systematic way with an objective quality assessment method called the Quality Index...... Method (QIM). It is foreseen that the QIM will be useful to give feedback to fishermen concerning the quality of their catch, which may in turn influence better handling on board. The QIM is a promising method for quick and reliable assessment of the freshness of fish. It is expected to become...

  4. Experience in testing and inspection and maintenance of material handling equipments

    International Nuclear Information System (INIS)

    Sharma, M.L.

    2009-01-01

    All the Industries, Power Projects/Stations, Organizations engaged in the field of process of manufacturing, power generation, transportation, design, layout, manufacturing, and supply have to utilize material handling equipment, machinery tools tackles, lifting gears for performing their tasks/activities. The major role of the material handling equipments play an important role and a component of 40% of the total activities of the system/process to achieve targeted output with the reliability and quality is performed by material handling equipment and machineries. The material handling equipment shall have to be chosen/selected to suit the process requirement at times to be specifically designed inspected and tested to meet the specific requirement. These equipment/machineries/lifting gears have to undergo for the periodical inspection and testing to qualify for further use in a specified period. All those equipment and machinery to be used for material handling if not found satisfactory during inspection and testing or otherwise also shall be dismantled/stripped to the extent of inspection requirement of the components/sub components and maintenance repair shall have to be done to make them worthy for reuse after testing and inspection duly witnessed by competent authority

  5. New Integrated Quality Function Deployment Approach Based on Interval Neutrosophic Set for Green Supplier Evaluation and Selection

    Directory of Open Access Journals (Sweden)

    Luu Huu Van

    2018-03-01

    Full Text Available Green supplier evaluation and selection plays a crucial role in the green supply chain management of any organization to reduce the purchasing cost of materials and increase the flexibility and quality of products. An interval neutrosophic set (INS—which is a generalization of fuzzy sets, intuitionistic fuzzy sets (IFS and neutrosophic sets (NS—can better handle the incomplete, indeterminate and inconsistent information than the other sets. This paper proposes a new integrated Quality Function Deployment (QFD in support of the green supplier evaluation and selection process. In the proposed approach, INS is used to assess the relative importance of the characteristics that the purchased product should have (internal variables “WHATs” in order to satisfy the company’s needs, the relevant supplier assessment criteria (external variables “HOWs”, the “HOWs”-“WHATs” correlation scores, the resulting weights of the “HOWs” and the impact of each potential supplier. The normalized weighted rating is then defined and the Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS method is developed to obtain a final ranking of green suppliers. A case study is applied to demonstrate the efficiency and computational procedure of the proposed method.

  6. Quality Evaluation of Mobile Game: Miftah Alfasaha

    Directory of Open Access Journals (Sweden)

    Ghada Alhuhud

    2016-01-01

    Full Text Available Due to evolution of digital games towards mobile platforms, a large exposure to mobile games is nowadays recorded. This is because of the availability of the cell phone with individuals anytime anywhere. Hence, a vital role of game quality assessment is raised. This is for the purpose of serving as a guide for developing healthy games. Accordingly, the mobile games would help in boosting the educational entertainment, healthy diets control, and behavioral sciences studies and research. This paper presents quality assurance and quality models for ISO based educational game. In this paper, an ISO quality model is presented and quality application behavioral impact measures are justified to evaluate the development quality of Miftah Alfasaha game. The quality model and proposed quality assessment plan are tested through a CodePro Analytix tool and six sigma evaluations.

  7. Ultrasound Image Quality Assessment: A framework for evaluation of clinical image quality

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian; Pedersen, Mads Møller; Nikolov, Svetoslav Ivanov

    2010-01-01

    Improvement of ultrasound images should be guided by their diagnostic value. Evaluation of clinical image quality is generally performed subjectively, because objective criteria have not yet been fully developed and accepted for the evaluation of clinical image quality. Based on recommendation 50...... information, which is fast enough to get sufficient number of scans under realistic operating conditions, so that statistical evaluation is valid and reliable....

  8. Evaluation Model of Tea Industry Information Service Quality

    OpenAIRE

    Shi , Xiaohui; Chen , Tian’en

    2015-01-01

    International audience; According to characteristics of tea industry information service, this paper have built service quality evaluation index system for tea industry information service quality, R-cluster analysis and multiple regression have been comprehensively used to contribute evaluation model with a high practice and credibility. Proved by the experiment, the evaluation model of information service quality has a good precision, which has guidance significance to a certain extent to e...

  9. Certification Plan, low-level waste Hazardous Waste Handling Facility

    International Nuclear Information System (INIS)

    Albert, R.

    1992-01-01

    The purpose of this plan is to describe the organization and methodology for the certification of low-level radioactive waste (LLW) handled in the Hazardous Waste Handling Facility (HWHF) at Lawrence Berkeley Laboratory (LBL). This plan also incorporates the applicable elements of waste reduction, which include both up-front minimization and end-product treatment to reduce the volume and toxicity of the waste; segregation of the waste as it applies to certification; an executive summary of the Waste Management Quality Assurance Implementing Management Plan (QAIMP) for the HWHF and a list of the current and planned implementing procedures used in waste certification. This plan provides guidance from the HWHF to waste generators, waste handlers, and the Waste Certification Specialist to enable them to conduct their activities and carry out their responsibilities in a manner that complies with the requirements of WHC-WAC. Waste generators have the primary responsibility for the proper characterization of LLW. The Waste Certification Specialist verifies and certifies that LBL LLW is characterized, handled, and shipped in accordance with the requirements of WHC-WAC. Certification is the governing process in which LBL personnel conduct their waste generating and waste handling activities in such a manner that the Waste Certification Specialist can verify that the requirements of WHC-WAC are met

  10. Characterization and handling solutions through development and adaptation of available technologies

    International Nuclear Information System (INIS)

    Michel, W.S.; Frazee, C.

    1998-01-01

    The Department of Energy (DOE) faces unique challenges in characterizing and handling its mixed wastes. Mixed waste is low-level or transuranic (TRU) contaminated wastes containing Resource Conservation and Recovery Act (RCRA) hazardous materials. Characterization and material handling technologies will be required to solve pretreatment and disposal needs, and to meet transportation requirements. The Mixed Waste Focus Area (MWFA) will fund the development and demonstration of characterization and material handling technologies to ensure the availability to support the DOE mixed waste needs. The MWFA will be evaluating commercially available and laboratory developed technologies for applicability in meeting these needs. Improved systems will be developed, on the commercial or laboratory side, as needed to address unmet needs. Studies/demonstrations are taking place this year to evaluate the capabilities of existing systems and identify technology gaps. Calls for proposals will be made to both industry and laboratory to identify work to address those gaps. Prioritization of applicable proposals will take place and activities funded appropriately to address characterization and material handling needs

  11. Adaptive handling of Rayleigh and Raman scatter of fluorescence data based on evaluation of the degree of spectral overlap

    Science.gov (United States)

    Hu, Yingtian; Liu, Chao; Wang, Xiaoping; Zhao, Dongdong

    2018-06-01

    At present the general scatter handling methods are unsatisfactory when scatter and fluorescence seriously overlap in excitation emission matrix. In this study, an adaptive method for scatter handling of fluorescence data is proposed. Firstly, the Raman scatter was corrected by subtracting the baseline of deionized water which was collected in each experiment to adapt to the intensity fluctuations. Then, the degrees of spectral overlap between Rayleigh scatter and fluorescence were classified into three categories based on the distance between the spectral peaks. The corresponding algorithms, including setting to zero, fitting on single or both sides, were implemented after the evaluation of the degree of overlap for individual emission spectra. The proposed method minimized the number of fitting and interpolation processes, which reduced complexity, saved time, avoided overfitting, and most importantly assured the authenticity of data. Furthermore, the effectiveness of this procedure on the subsequent PARAFAC analysis was assessed and compared to Delaunay interpolation by conducting experiments with four typical organic chemicals and real water samples. Using this method, we conducted long-term monitoring of tap water and river water near a dyeing and printing plant. This method can be used for improving adaptability and accuracy in the scatter handling of fluorescence data.

  12. Evaluation of quality in social-work practice

    Directory of Open Access Journals (Sweden)

    Björn Blom

    2012-09-01

    Full Text Available This theoretical article describes and discusses the concept of quality in relation to the evaluation of social-work practice. Of particular interest are the difference between quality of services and quality of life and the importance of balancing the stakeholders’ different interests in order to make a sound judgement of quality in social work possible. This article begins with presenting some basic perspectives on quality as well as the transference of the concept of quality from manufacturing industry to social-work practice. Thereafter the two main issues are discussed: the concepts of quality of service and of quality of life and the importance of balancing different stakeholders’ perspectives in the evaluation of quality in social-work practice. This article concludes that: 1 it is crucial to be aware of and to consider the distinction between quality of service and quality of life; 2 clients’ perspective on quality of life is an aspect of outcome that currently receives insufficient attention; 3 clients’ subjective experiences of welfare of well-being deserve greater attention for ethical as well as methodological reasons; and 4 judgement of quality in social work are inevitably dependent on different stakeholders’ perspectives.

  13. A review of the current state-of-the-art methodology for handling bias and uncertainty in performing criticality safety evaluations. Final report

    International Nuclear Information System (INIS)

    Disney, R.K.

    1994-10-01

    The methodology for handling bias and uncertainty when calculational methods are used in criticality safety evaluations (CSE's) is a rapidly evolving technology. The changes in the methodology are driven by a number of factors. One factor responsible for changes in the methodology for handling bias and uncertainty in CSE's within the overview of the US Department of Energy (DOE) is a shift in the overview function from a ''site'' perception to a more uniform or ''national'' perception. Other causes for change or improvement in the methodology for handling calculational bias and uncertainty are; (1) an increased demand for benchmark criticals data to expand the area (range) of applicability of existing data, (2) a demand for new data to supplement existing benchmark criticals data, (3) the increased reliance on (or need for) computational benchmarks which supplement (or replace) experimental measurements in critical assemblies, and (4) an increased demand for benchmark data applicable to the expanded range of conditions and configurations encountered in DOE site restoration and remediation

  14. Motives, barriers and quality evaluation in fish consumption situations

    DEFF Research Database (Denmark)

    Brunsø, Karen; Verbeke, Wim; Olsen, Svein Ottar

    2009-01-01

    and user groups with respect to preparation skills and the use of quality cues. Heavy users are very skilled in evaluating fish quality, especially those in Spain, while light users, especially those in Belgium, make seemingly irrational assumptions when evaluating the quality of fish. Research limitations...... research into explaining variations in fish consumption, as well as for fish quality evaluation and fish market segmentation studies....

  15. Uranium hexafluoride: A manual of good handling practices. Revision 7

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-01-01

    The United States Enrichment Corporation (USEC) is continuing the policy of the US Department of Energy (DOE) and its predecessor agencies in sharing with the nuclear industry their experience in the area of uranium hexafluoride (UF{sub 6}) shipping containers and handling procedures. The USEC has reviewed Revision 6 or ORO-651 and is issuing this new edition to assure that the document includes the most recent information on UF{sub 6} handling procedures and reflects the policies of the USEC. This manual updates the material contained in earlier issues. It covers the essential aspects of UF{sub 6} handling, cylinder filling and emptying, general principles of weighing and sampling, shipping, and the use of protective overpacks. The physical and chemical properties of UF{sub 6} are also described. The procedures and systems described for safe handling of UF{sub 6} presented in this document have been developed and evaluated during more than 40 years of handling vast quantities of UF{sub 6}. With proper consideration for its nuclear properties, UF{sub 6} may be safely handled in essentially the same manner as any other corrosive and/or toxic chemical.

  16. The FMEA Analysis for Fuel Handling System at Cernavoda Unit 2

    International Nuclear Information System (INIS)

    Park, Jin Hee; Kim, Tae Woon; Rhee, Bo Wook; Yoon, Chul; Kim, Hyeong Tae; Cho, In Gil; Kim, Seong Ho

    2006-01-01

    A Nuclear Safety Evaluation was performed by an independent assessor at the request of the regulatory authority CNCAN (Comisia Nationala pentru Controlul Activitatilor Nucleare. National Committee for Nuclear Activities Control in Romania) to provide an independent overview of all the nuclear safety aspects of Cernavoda Unit 2 under construction and an expert opinion whether the completed Cernavoda Unit-2 Nuclear Power Plant would satisfy current Western European nuclear safety objectives and practices. A report was produced (Cernavoda 2 Nuclear Safety Expert Project, 'Task 10 . Safety Evaluation Report', A.F.Parsons, NNC Limited, December 2001) and contains recommendations either mandatory or advisory. The FMEA study, one of the mandatory recommendations, is performing now for fuel handling system and radioactive waste handling system for Cernavoda unit 2 in Romania sponsored by KHNP. In this paper, only the FMEA study for fuel handling system is presented

  17. Quality and Research Evaluation in Organizations

    DEFF Research Database (Denmark)

    Hansson, Finn

    A central issue in science policy today is the changing role and function ofresearch evaluation. How is quality selected, has local organizational traditionsand managerial practices influence on the research evaluation? Who isperceived as peers or evaluators by the researchers and by managers...

  18. Develop Quality Characteristics Based Quality Evaluation Process for Ready to Use Software Products

    OpenAIRE

    Daiju Kato; Hiroshi Ishikawa

    2016-01-01

    The users who use ready to use software product had better get the products’ quality information with classified by some kind of global standard metrics or technique for their evaluation. But many of those software products’ co mpanies don’t provide the quality information because of the products are developed b y their own development and evaluation process. But those users want to get quality i...

  19. The study of surgical image quality evaluation system by subjective quality factor method

    Science.gov (United States)

    Zhang, Jian J.; Xuan, Jason R.; Yang, Xirong; Yu, Honggang; Koullick, Edouard

    2016-03-01

    GreenLightTM procedure is an effective and economical way of treatment of benign prostate hyperplasia (BPH); there are almost a million of patients treated with GreenLightTM worldwide. During the surgical procedure, the surgeon or physician will rely on the monitoring video system to survey and confirm the surgical progress. There are a few obstructions that could greatly affect the image quality of the monitoring video, like laser glare by the tissue and body fluid, air bubbles and debris generated by tissue evaporation, and bleeding, just to name a few. In order to improve the physician's visual experience of a laser surgical procedure, the system performance parameter related to image quality needs to be well defined. However, since image quality is the integrated set of perceptions of the overall degree of excellence of an image, or in other words, image quality is the perceptually weighted combination of significant attributes (contrast, graininess …) of an image when considered in its marketplace or application, there is no standard definition on overall image or video quality especially for the no-reference case (without a standard chart as reference). In this study, Subjective Quality Factor (SQF) and acutance are used for no-reference image quality evaluation. Basic image quality parameters, like sharpness, color accuracy, size of obstruction and transmission of obstruction, are used as subparameter to define the rating scale for image quality evaluation or comparison. Sample image groups were evaluated by human observers according to the rating scale. Surveys of physician groups were also conducted with lab generated sample videos. The study shows that human subjective perception is a trustworthy way of image quality evaluation. More systematic investigation on the relationship between video quality and image quality of each frame will be conducted as a future study.

  20. Safe meat-handling knowledge, attitudes and practices of private and government meat processing plants' workers: implications for future policy.

    Science.gov (United States)

    Adesokan, H K; Raji, A O Q

    2014-03-01

    Food-borne disease outbreaks remain a major global health challenge and cross-contamination from raw meat due to poor handling is a major cause in developing countries. Adequate knowledge of meat handlers is important in limiting these outbreaks. This study evaluated and compared the safe meat-handling knowledge, attitudes and practices (KAP) of private (PMPP) and government meat processing plants' (GMPP) workers in south-western Nigeria. This cross sectional study comprised 190 meat handlers (PMPP = 55; GMPP = 135). Data concerning their safe meat-handling knowledge, attitudes and practices as well as their socio-demographic characteristics, such as age, gender and work experience were collected. A significant association was observed between the type of meat processing plants and their knowledge (p = 0.000), attitudes (p = 0.000) and practices (p = 0.000) of safe meat-handling. Meat handlers in the GMPP were respectively, about 17 times (OR = 0.060, 95% CI: 0.018-0.203), 57 times (OR = 0.019, 95% CI: 0.007-0.054) and 111 times (OR = 0.009, 95% CI: 0.001- 0.067) less likely to obtain good knowledge, attitude and practice level of safe meat-handling than those from PMPP. Further, KAP levels were significantly associated with age group, education and work experience (p < 0.05). Study findings suggest the need for future policy in food industry in developing countries to accommodate increased involvement of private sector for improved food safety and quality delivery. Public health education on safe food handling and hygiene should be on the front burner among food handlers in general.

  1. Evaluating supplier quality performance using analytical hierarchy process

    Science.gov (United States)

    Kalimuthu Rajoo, Shanmugam Sundram; Kasim, Maznah Mat; Ahmad, Nazihah

    2013-09-01

    This paper elaborates the importance of evaluating supplier quality performance to an organization. Supplier quality performance evaluation reflects the actual performance of the supplier exhibited at customer's end. It is critical in enabling the organization to determine the area of improvement and thereafter works with supplier to close the gaps. Success of the customer partly depends on supplier's quality performance. Key criteria as quality, cost, delivery, technology support and customer service are categorized as main factors in contributing to supplier's quality performance. 18 suppliers' who were manufacturing automotive application parts evaluated in year 2010 using weight point system. There were few suppliers with common rating which led to common ranking observed by few suppliers'. Analytical Hierarchy Process (AHP), a user friendly decision making tool for complex and multi criteria problems was used to evaluate the supplier's quality performance challenging the weight point system that was used for 18 suppliers'. The consistency ratio was checked for criteria and sub-criteria. Final results of AHP obtained with no overlap ratings, therefore yielded a better decision making methodology as compared to weight point rating system.

  2. MRI evaluation of the bucket handle tears of menisci of the knee

    International Nuclear Information System (INIS)

    Zheng Zhuozhao; Fan Jiadong; Xie Jingxia

    2003-01-01

    Objective: To determine the value of five MR imaging signs in diagnosing the bucket handle tears (BHT) of menisci of the knee. Methods: MR imaging of 139 knees with subsequent arthroscopy exams were retrospectively evaluated. Based on the results of arthroscopy, 19 knees had BHT of menisci. Two radiologists evaluated each MR exam independently, with discrepancies resolved by consensus. Each MR exam was analyzed for five signs: a double posterior cruciate ligament sign, a flipped meniscus sign, an absent bow tie sign, an internal displaced fragment sign, and an abnormal circumferential meniscus sign. Sensitivity, specificity, positive and negative predictive values, and accuracy for diagnosing BHT of menisci were calculated for the presence of each individual sign. Results: The sensitivities of these five signs ranged between 52.6% and 89.5%, and specificities ranged between 83.3% and 98.3%, respectively. Positive and negative predictive values ranged between 42.9% and 88.2%, and between 92.7% and 98.3%, respectively. The accuracy of these five signs ranged between 82.7% and 96.4%. Conclusion: BHT of menisci may have many signs on MR imaging. The diagnostic sensitivities of the internal displaced fragment sign and the abnormal circumferential meniscus sign are the highest. The double posterior cruciate ligament sign has the highest specificity and positive predictive value, while the internal displaced fragment sign has the highest negative predictive value and accuracy

  3. Can Control Banding be Useful for the Safe Handling of Nanomaterials? A Systematic Review

    Science.gov (United States)

    Eastlake, Adrienne; Zumwalde, Ralph; Geraci, Charles

    2016-01-01

    Objectives Control banding (CB) is a risk management strategy that has been used to identify and recommend exposure control measures to potentially hazardous substances for which toxicological information is limited. The application of CB and level of expertise required for implementation and management can differ depending on knowledge of the hazard potential, the likelihood of exposure, and the ability to verify the effectiveness of exposure control measures. A number of different strategies have been proposed for using CB in workplaces where exposure to engineered nanomaterials (ENMs) can occur. However, it is unclear if the use of CB can effectively reduce worker exposure to nanomaterials. A systematic review of studies was conducted to answer the question “can control banding be useful to ensure adequate controls for the safe handling of nanomaterials.” Methods A variety of databases were searched to identify relevant studies pertaining to CB. Database search terms included ‘control’, ‘hazard’, ‘exposure’ and ‘risk’ banding as well as the use of these terms in the context of nanotechnology or nanomaterials. Other potentially relevant studies were identified during the review of articles obtained in the systematic review process. Identification of studies and the extraction of data were independently conducted by the reviewers. Quality of the studies was assessed using the Methodological Index for Non-Randomized Studies (MINORS). The quality of the evidence was evaluated using Grading of Recommendations Assessment, Development and Evaluation (GRADE). Results A total of 235 records were identified in the database search in which 70 records were determined to be eligible for full-text review. Only two studies were identified that met the inclusion criteria. These studies evaluated the application of the CB Nanotool in workplaces where ENMs were being handled. A total of 32 different nanomaterial handling activities were evaluated in these

  4. Can control banding be useful for the safe handling of nanomaterials? A systematic review

    International Nuclear Information System (INIS)

    Eastlake, Adrienne; Zumwalde, Ralph; Geraci, Charles

    2016-01-01

    Control banding (CB) is a risk management strategy that has been used to identify and recommend exposure control measures to potentially hazardous substances for which toxicological information is limited. The application of CB and level of expertise required for implementation and management can differ depending on knowledge of the hazard potential, the likelihood of exposure, and the ability to verify the effectiveness of exposure control measures. A number of different strategies have been proposed for using CB in workplaces where exposure to engineered nanomaterials (ENMs) can occur. However, it is unclear if the use of CB can effectively reduce worker exposure to nanomaterials. A systematic review of studies was conducted to answer the question “can control banding be useful to ensure adequate controls for the safe handling of nanomaterials.” A variety of databases were searched to identify relevant studies pertaining to CB. Database search terms included ‘control,’ ‘hazard,’ ‘exposure,’ and ‘risk’ banding as well as the use of these terms in the context of nanotechnology or nanomaterials. Other potentially relevant studies were identified during the review of articles obtained in the systematic review process. Identification of studies and the extraction of data were independently conducted by the reviewers. Quality of the studies was assessed using the methodological index for nonrandomized studies. The quality of the evidence was evaluated using grading of recommendations assessment, development and evaluation (GRADE). A total of 235 records were identified in the database search in which 70 records were determined to be eligible for full-text review. Only two studies were identified that met the inclusion criteria. These studies evaluated the application of the CB Nanotool in workplaces where ENMs were being handled. A total of 32 different nanomaterial handling activities were evaluated in these studies by comparing the recommended

  5. Can control banding be useful for the safe handling of nanomaterials? A systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Eastlake, Adrienne, E-mail: aeastlake@cdc.gov [National Institute for Occupational Safety and Health, Nanotechnology Research Center (United States); Zumwalde, Ralph [RCS Corporation (United States); Geraci, Charles [National Institute for Occupational Safety and Health, Nanotechnology Research Center (United States)

    2016-06-15

    Control banding (CB) is a risk management strategy that has been used to identify and recommend exposure control measures to potentially hazardous substances for which toxicological information is limited. The application of CB and level of expertise required for implementation and management can differ depending on knowledge of the hazard potential, the likelihood of exposure, and the ability to verify the effectiveness of exposure control measures. A number of different strategies have been proposed for using CB in workplaces where exposure to engineered nanomaterials (ENMs) can occur. However, it is unclear if the use of CB can effectively reduce worker exposure to nanomaterials. A systematic review of studies was conducted to answer the question “can control banding be useful to ensure adequate controls for the safe handling of nanomaterials.” A variety of databases were searched to identify relevant studies pertaining to CB. Database search terms included ‘control,’ ‘hazard,’ ‘exposure,’ and ‘risk’ banding as well as the use of these terms in the context of nanotechnology or nanomaterials. Other potentially relevant studies were identified during the review of articles obtained in the systematic review process. Identification of studies and the extraction of data were independently conducted by the reviewers. Quality of the studies was assessed using the methodological index for nonrandomized studies. The quality of the evidence was evaluated using grading of recommendations assessment, development and evaluation (GRADE). A total of 235 records were identified in the database search in which 70 records were determined to be eligible for full-text review. Only two studies were identified that met the inclusion criteria. These studies evaluated the application of the CB Nanotool in workplaces where ENMs were being handled. A total of 32 different nanomaterial handling activities were evaluated in these studies by comparing the recommended

  6. Ontology Based Quality Evaluation for Spatial Data

    Science.gov (United States)

    Yılmaz, C.; Cömert, Ç.

    2015-08-01

    Many institutions will be providing data to the National Spatial Data Infrastructure (NSDI). Current technical background of the NSDI is based on syntactic web services. It is expected that this will be replaced by semantic web services. The quality of the data provided is important in terms of the decision-making process and the accuracy of transactions. Therefore, the data quality needs to be tested. This topic has been neglected in Turkey. Data quality control for NSDI may be done by private or public "data accreditation" institutions. A methodology is required for data quality evaluation. There are studies for data quality including ISO standards, academic studies and software to evaluate spatial data quality. ISO 19157 standard defines the data quality elements. Proprietary software such as, 1Spatial's 1Validate and ESRI's Data Reviewer offers quality evaluation based on their own classification of rules. Commonly, rule based approaches are used for geospatial data quality check. In this study, we look for the technical components to devise and implement a rule based approach with ontologies using free and open source software in semantic web context. Semantic web uses ontologies to deliver well-defined web resources and make them accessible to end-users and processes. We have created an ontology conforming to the geospatial data and defined some sample rules to show how to test data with respect to data quality elements including; attribute, topo-semantic and geometrical consistency using free and open source software. To test data against rules, sample GeoSPARQL queries are created, associated with specifications.

  7. Development and evaluation of a multifaceted ergonomics program to prevent injuries associated with patient handling tasks.

    Science.gov (United States)

    Nelson, Audrey; Matz, Mary; Chen, Fangfei; Siddharthan, Kris; Lloyd, John; Fragala, Guy

    2006-08-01

    Nurses have one of the highest rates of work-related musculoskeletal injury of any profession. Over the past 30 years, efforts to reduce work-related musculoskeletal disorders in nurses have been largely unsuccessful. The primary goal of this program was to create safer working environments for nursing staff who provide direct patient care. Our first objective was to design and implement a multifaceted program that successfully integrated evidence-based practice, technology, and safety improvement. The second objective was to evaluate the impact of the program on injury rate, lost and modified work days, job satisfaction, self-reported unsafe patient handling acts, level of support for program, staff and patient acceptance, program effectiveness, costs, and return on investment. The intervention included six program elements: (1) Ergonomic Assessment Protocol, (2) Patient Handling Assessment Criteria and Decision Algorithms, (3) Peer Leader role, "Back Injury Resource Nurses", (4) State-of-the-art Equipment, (5) After Action Reviews, and (6) No Lift Policy. A pre-/post design without a control group was used to evaluate the effectiveness of a patient care ergonomics program on 23 high risk units (19 nursing home care units and 4 spinal cord injury units) in 7 facilities. Injury rates, lost work days, modified work days, job satisfaction, staff , and patient acceptance, program effectiveness, and program costs/savings were compared over two nine month periods: pre-intervention (May 2001-January 2002) and post-intervention (March 2002-November 2002). Data were collected prospectively through surveys, weekly process logs, injury logs, and cost logs. The program elements resulted in a statistically significant decrease in the rate of musculoskeletal injuries as well as the number of modified duty days taken per injury. While the total number of lost workdays decreased by 18% post-intervention, this difference was not statistically significant. There were statistically

  8. A mixed methods approach to developing and evaluating oncology trainee education around minimization of adverse events and improved patient quality and safety.

    Science.gov (United States)

    Janssen, Anna; Shaw, Tim; Bradbury, Lauren; Moujaber, Tania; Nørrelykke, Anne Mette; Zerillo, Jessica A; LaCasce, Ann; Co, John Patrick T; Robinson, Tracy; Starr, Alison; Harnett, Paul

    2016-03-12

    Adverse events are a significant quality and safety issue in the hospital setting due to their direct impact on patients. Additionally, such events are often handled by junior doctors due to their direct involvement with patients. As such, it is important for health care organizations to prioritize education and training for junior doctors on identifying adverse events and handling them when they occur. The Cancer Cup Challenge is an educational program focuses on quality improvement and adverse event awareness targeting for junior oncology doctors across three international sites. A mixed methodology was used to develop and evaluate the program. The Qstream spaced learning platform was used to disseminate information to participants, as it has been demonstrated to impact on both knowledge and behavior. Eight short case based scenarios with expert feedback were developed by a multidisciplinary advisory committee containing representatives from the international sites. At the conclusion of the course impact on participant knowledge was evaluated using analysis of the metrics collected by the Qstream platform. Additionally, an online survey and semi-structured interviews were used to evaluate engagement and perceived value by participants. A total of 35 junior doctors registered to undertake the Qstream program, with 31 (88.57 %) successfully completing it. Analysis of the Qstream metrics revealed 76.57 % of cases were answered correctly on first attempt. The post-program survey received 17 responses, with 76.47 % indicating cases for the course were interesting and 82.35 % feeling cases were relevant. Finally, 14 participants consented to participate in semi-structured interviews about the program, with feedback towards the course being generally very positive. Our study demonstrates that an online game is well accepted by junior doctors as a method to increase their quality improvement awareness. Developing effective and sustainable training for doctors is

  9. Course Evaluation Systems for Open-ended Quality Enhancement

    DEFF Research Database (Denmark)

    Piihl, Jesper; Rasmussen, Jens Smed

    2013-01-01

    Quality in higher education is widely controlled through surveys asking students to evaluate teaching. However, control of quality does not necessarily lead to enhancement of quality. Drawing on accounting research and a case study, a measurement-based and open-ended quality control system...... emphasising quality enhancement is suggested. The case shows how interactive use of performance measurement can lead to more engaged and enabling dialogue amongst involved actors concerning quality enhancement, however institutionalised beliefs regarding course evaluation systems makes a change challenging....... The chapter suggests that open-ended measurement systems enabling stakeholders to take responsibility for quality enhancement is not so much a matter of technical design as a matter of an enabling style of use....

  10. Construction and operation of replacement hazardous waste handling facility at Lawrence Berkeley Laboratory

    International Nuclear Information System (INIS)

    1992-09-01

    The US Department of Energy (DOE) has prepared an environmental assessment (EA), DOE/EA-0423, for the construction and operation of a replacement hazardous waste handling facility (HWHF) and decontamination of the existing HWHF at Lawrence Berkeley Laboratory (LBL), Berkeley, California. The proposed facility would replace several older buildings and cargo containers currently being used for waste handling activities and consolidate the LBL's existing waste handling activities in one location. The nature of the waste handling activities and the waste volume and characteristics would not change as a result of construction of the new facility. Based on the analysis in the EA, DOE has determined that the proposed action would not constitute a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act (NEPA) of 1969, 42 USC. 4321 et seq. Therefore, an environmental impact statement is not required

  11. Design and safety evaluation of radioactive gas handling and storage in the FFTF

    International Nuclear Information System (INIS)

    Armstrong, G.R.; Hale, J.P.; Halverson, T.G.

    1976-01-01

    During the operation of the Fast Flux Test Facility (FFTF), radioactive gases, primarily xenon and krypton, will be produced which will require processing and storing. Two systems have been installed in the FFTF for handling these gases: (1) one to handle, primarily, the reactor cover gas system, and (2) a second to handle the cells and cover gas systems, other than the reactor, whose atmosphere may become contaminated. The system that processes the reactor cover gas, which is argon, is called the Radioactive Argon Processing System (RAPS). The effluent argon from RAPS will normally be sufficiently decontaminated to allow its reuse as the reactor cover gas. If the radioactive level in the RAPS becomes too high, the exhaust stream will be diverted to the Cell Atmosphere Processing System (CAPS), a system which can function as a backup to RAPS. The design and operation of the RAPS and CAPS systems are described and certain safety aspects of the systems are discussed. It is shown that these systems adequately provide the cleanup services required and that they provide the safety margins necessary to assure adequate safety to the public

  12. Quality of Life Among Radiation Workers

    International Nuclear Information System (INIS)

    Ibrahim, M.S.

    2013-01-01

    Quality of life (QOL) is a general term applied to the totality of physical, psychological, and social functioning. The World Health Organization (WHO) regards health as a state of complete physical, mental, and social well being, and not merely the absence of disease. Every person's life is different, and thus the way in which each person experiences a QOL is unique. Individuals lead complex lives that have many dimensions. A QOL approach recognizes that there are many different aspects of living that may contribute to quality. In this study, Quality of life was evaluated using the Short Form 36 (SF-36) questionnaire for one hundred and fifty radiation workers who handled ionizing radiation for at least twelve years, and one hundred fifty control individuals who did not knowingly come in contact with any radiation source., the QOL effects on work and achievements were also evaluated. Results revealed that radiation workers have lower quality of life compared to those who never come in contact with a radiation source

  13. Study on a Quality Evaluation Method for College English Classroom Teaching

    Directory of Open Access Journals (Sweden)

    Mao-hua Sun

    2017-07-01

    Full Text Available A quality evaluation method is an important means and the main basis on which to evaluate the college English classroom teaching quality of teachers. To overcome the one-sided subjectivity and resulting imprecision of the traditional classroom teaching quality evaluation method, a scientific and reasonable quality evaluation index system for college English classroom teaching is constructed. The fuzzy comprehensive evaluation method and the analytic hierarchy process method are combined to propose an improved multi-level fuzzy comprehensive evaluation model for obtaining a new college English classroom teaching quality evaluation method. In the proposed method, according to the fuzzy characteristics of a college English classroom teaching quality evaluation, the fuzzy comprehensive evaluation method is used to transform the qualitative evaluation indexes into limited quantitative evaluation indexes, then a judgment matrix is constructed to determine the weights among different levels by using the analytic hierarchy process method. Additionally, the college English classroom teaching quality is evaluated in detail. Finally, an actual case of college English classroom teaching is used to verify the effectiveness of the college English classroom teaching quality evaluation method. The results show that the proposed college English classroom teaching method can overcome the subjectivity and randomness shortcomings of the traditional classroom teaching quality evaluation methods, and improve the reliability, accuracy, and objectivity of fuzzy comprehensive evaluation. It is an effective method to evaluate college English classroom teaching quality.

  14. Bucket-handle meniscal tears of the knee: sensitivity and specificity of MRI signs

    International Nuclear Information System (INIS)

    Dorsay, Theodore A.; Helms, Clyde A.

    2003-01-01

    To determine the sensitivity and specificity of reported MRI signs in the evaluation of bucket-handle tears of the knee.Design and patients A retrospective analysis of 71 knee MR examinations that were read as displaying evidence of a bucket-handle or ''bucket-handle type'' tear was performed. We evaluated for the presence or absence of the absent bow tie sign, the coronal truncation sign, the double posterior cruciate ligament (PCL) sign, the anterior flipped fragment sign, and a fragment displaced into the intercondylar notch. Sensitivity and specificity were calculated relative to the gold standard of arthroscopy. Forty-three of 71 cases were surgically proven as bucket-handle tears. The absent bow tie sign demonstrated a sensitivity of 88.4%. The presence of at least one of the displaced fragment signs had a sensitivity of 90.7%. A finding of both the absent bow tie sign and one of the displaced fragment signs demonstrated a specificity of 85.7%. The double PCL sign demonstrated a specificity of 100%. The anterior flipped meniscus sign had a specificity of 89.7%. Bucket-handle tears of the menisci, reported in about 10% of most large series, have been described by several signs with MRI. This report gives the sensitivity and specificity of MRI for bucket-handle tears using each of these signs independently and in combination. MRI is shown to be very accurate for diagnosing bucket-handle tears when two or more of these signs coexist. (orig.)

  15. Ergonomic material-handling device

    Science.gov (United States)

    Barsnick, Lance E.; Zalk, David M.; Perry, Catherine M.; Biggs, Terry; Tageson, Robert E.

    2004-08-24

    A hand-held ergonomic material-handling device capable of moving heavy objects, such as large waste containers and other large objects requiring mechanical assistance. The ergonomic material-handling device can be used with neutral postures of the back, shoulders, wrists and knees, thereby reducing potential injury to the user. The device involves two key features: 1) gives the user the ability to adjust the height of the handles of the device to ergonomically fit the needs of the user's back, wrists and shoulders; and 2) has a rounded handlebar shape, as well as the size and configuration of the handles which keep the user's wrists in a neutral posture during manipulation of the device.

  16. Remote handling needs of the Princeton Plasma Physics Laboratory

    International Nuclear Information System (INIS)

    Smiltnieks, V.

    1982-07-01

    This report is the result of a Task Force study commissioned by the Canadian Fusion Fuels Technology Project (CFFTP) to investigate the remote handling requirements at the Princeton Plasma Physics Laboratory (PPPL) and identify specific areas where CFFTP could offer a contractual or collaborative participation, drawing on the Canadian industrial expertise in remote handling technology. The Task Force reviewed four areas related to remote handling requirements; the TFTR facility as a whole, the service equipment required for remote maintenance, the more complex in-vessel components, and the tritium systems. Remote maintenance requirements both inside the vacuum vessel and around the periphery of the machine were identified as the principal areas where Canadian resources could effectively provide an input, initially in requirement definition, concept evaluation and feasibility design, and subsequently in detailed design and manufacture. Support requirements were identified in such areas as the mock-up facility and a variety of planning studies relating to reliability, availability, and staff training. Specific tasks are described which provide an important data base to the facility's remote handling requirements. Canadian involvement in the areas is suggested where expertise exists and support for the remote handling work is warranted. Reliability, maintenance operations, inspection strategy and decommissioning are suggested for study. Several specific components are singled out as needing development

  17. Evaluation of Quality Parameters in Water Resource Planning. (A State-of-the-Art Survey of the Economics of Water Quality)

    Science.gov (United States)

    1974-12-01

    comparative costs, damages, and benefits. 6. Checklist of data required for solving a typical water quality problem. Algorithms and checklists for solving...missing is an algorithm for handling simultaneously a large number of variables for reaching an over-all optimal solution. CONTENTS TC-1 TABLE OF...stirred tank reactor" ( CSTR ) elements, with water flowing from one to the next. For each time interval, a multiple-step explicit solution was used to

  18. Evaluation of headache service quality indicators

    DEFF Research Database (Denmark)

    Katsarava, Zaza; Gouveia, Raquel Gil; Jensen, Rigmor

    2015-01-01

    that deficiencies in headache care worldwide might be recognized and rectified. These indicators themselves require evaluation and proof of fitness for purpose. This pilot study begins this process. METHODS: We tested the quality indicators in the tertiary headache centres of the University of Duisburg...... of ensuring equal access to the services); and over protocols for reporting serious adverse events. CONCLUSION: This pilot study to assess feasibility of the methods and acceptability of the instruments of headache service quality evaluation was successful. The project is ready to be taken into its next...

  19. Suppliers' activities within the controlled zones of licensees handling ionizing radiation sources. Recommendations

    International Nuclear Information System (INIS)

    1999-01-01

    The Recommendations are intended to lay down a unified procedure for preparing licence applications related to ionizing radiation source handling, including the required documentation. The guidelines were set up based on documents of the Dukovany nuclear power plant and adapted to serve the Temelin nuclear power plant and other workplaces handling ionizing radiation sources as well. Selected provisions of applicable legislation are reproduced, and responsibilities are described. The major part of the publication is constituted by model documents, particularly a model Quality Assurance Programme. (P.A.)

  20. CLASSIFICATION OF THE MGR WASTE HANDLING BUILDING VENTILATION SYSTEM

    International Nuclear Information System (INIS)

    J.A. Ziegler

    2000-01-01

    The purpose of this analysis is to document the Quality Assurance (QA) classification of the Monitored Geologic Repository (MGR) waste handling building ventilation system structures, systems and components (SSCs) performed by the MGR Preclosure Safety and Systems Engineering Section. This analysis also provides the basis for revision of YMP/90-55Q, Q-List (YMP 2000). The Q-List identifies those MGR SSCs subject to the requirements of DOE/RW-0333P, ''Quality Assurance Requirements and Description'' (QARD) (DOE 2000). This QA classification incorporates the current MGR design and the results of the ''Design Basis Event Frequency and Dose Calculation for Site Recommendation'' (CRWMS M andO 2000a) and ''Bounding Individual Category 1 Design Basis Event Dose Calculation to Support Quality Assurance Classification'' (Gwyn 2000)

  1. Evaluation study on rationalization of coal handling in snowy area

    Energy Technology Data Exchange (ETDEWEB)

    Suesada, Yasuhiko; Yamagata, Keisuke; Kuwahara, Mitsuhiro

    1987-09-25

    The adhesion of coal to the coal handling facilities in large cool-fired power plants in the snowy area was investigated for siting them in the future. The amount of water derived from melted snow in addition to that from the rain fall were measured and the statistical amounts of rain and snow falls for the past ten years were examined. Then the amount of water derived from melted snow was calculated by regression. The result indicates that the amount of rain fall in summer is larger than that from melted snow. The moisture content of coal in a coal yard reaches the moisture content at which the coal readily adheres to the facilities after snow fall and it penetrates the pile of coal to the bottom with the lapse of time. The penetrating rate of it largely depends upon the particle distribution of coal as well as the ranks of coal. The adhesion of coal to the coal handling facilities is caused mainly by the amount of dust coal and the moisture content of coal. The amount of adhered coal estimated from the shear properties qualitatively agrees with the experimental result using a model of chute. Adding the dusting inhibitor exceeding the normal value increases the amount of of adhesion of coal. (13 figs, 3 tabs)

  2. A semi-automated tool for treatment plan-quality evaluation and clinical trial quality assurance

    Science.gov (United States)

    Wang, Jiazhou; Chen, Wenzhou; Studenski, Matthew; Cui, Yunfeng; Lee, Andrew J.; Xiao, Ying

    2013-07-01

    The goal of this work is to develop a plan-quality evaluation program for clinical routine and multi-institutional clinical trials so that the overall evaluation efficiency is improved. In multi-institutional clinical trials evaluating the plan quality is a time-consuming and labor-intensive process. In this note, we present a semi-automated plan-quality evaluation program which combines MIMVista, Java/MATLAB, and extensible markup language (XML). More specifically, MIMVista is used for data visualization; Java and its powerful function library are implemented for calculating dosimetry parameters; and to improve the clarity of the index definitions, XML is applied. The accuracy and the efficiency of the program were evaluated by comparing the results of the program with the manually recorded results in two RTOG trials. A slight difference of about 0.2% in volume or 0.6 Gy in dose between the semi-automated program and manual recording was observed. According to the criteria of indices, there are minimal differences between the two methods. The evaluation time is reduced from 10-20 min to 2 min by applying the semi-automated plan-quality evaluation program.

  3. A semi-automated tool for treatment plan-quality evaluation and clinical trial quality assurance

    International Nuclear Information System (INIS)

    Wang, Jiazhou; Chen, Wenzhou; Studenski, Matthew; Cui, Yunfeng; Xiao, Ying; Lee, Andrew J

    2013-01-01

    The goal of this work is to develop a plan-quality evaluation program for clinical routine and multi-institutional clinical trials so that the overall evaluation efficiency is improved. In multi-institutional clinical trials evaluating the plan quality is a time-consuming and labor-intensive process. In this note, we present a semi-automated plan-quality evaluation program which combines MIMVista, Java/MATLAB, and extensible markup language (XML). More specifically, MIMVista is used for data visualization; Java and its powerful function library are implemented for calculating dosimetry parameters; and to improve the clarity of the index definitions, XML is applied. The accuracy and the efficiency of the program were evaluated by comparing the results of the program with the manually recorded results in two RTOG trials. A slight difference of about 0.2% in volume or 0.6 Gy in dose between the semi-automated program and manual recording was observed. According to the criteria of indices, there are minimal differences between the two methods. The evaluation time is reduced from 10–20 min to 2 min by applying the semi-automated plan-quality evaluation program. (note)

  4. Quality assurance (QA) procedures for software: Evaluation of an ADC quality system

    International Nuclear Information System (INIS)

    Efstathopoulos, E. P.; Benekos, O.; Molfetas, M.; Charou, E.; Kottou, S.; Argentos, S.; Kelekis, N. L.

    2005-01-01

    Image viewing and processing software in computed radiography manipulates image contrast in such a way that all relevant image features are rendered to an appropriate degree of visibility, and improves image quality using enhancement algorithms. The purpose of this study was to investigate procedures for the quality assessment of image processing software for computed radiography with the use of existing test objects and to assess the influence that processing introduces on physical image quality characteristics. Measurements of high-contrast resolution, low-contrast resolution, spatial resolution, grey scale (characteristic curve) and geometric distortion were performed 'subjectively' by three independent observers and 'objectively' by the use of criteria based on pixel intensity values. Results show quality assessment is possible without the need for human evaluators, using digital images. It was discovered that the processing software evaluated in this study was able to improve some aspects of image quality, without introducing geometric distortion. (authors)

  5. Current status of quality evaluation of nursing care through director review and reflection from the Nursing Quality Control Centers

    Science.gov (United States)

    Duan, Xia; Shi, Yan

    2014-01-01

    Background: The quality evaluation of nursing care is a key link in medical quality management. It is important and worth studying for the nursing supervisors to know the disadvantages during the process of quality evaluation of nursing care and then to improve the whole nursing quality. This study was to provide director insight on the current status of quality evaluation of nursing care from Nursing Quality Control Centers (NQCCs). Material and Methods: This qualitative study used a sample of 12 directors from NQCCs who were recruited from 12 provinces in China to evaluate the current status of quality evaluation of nursing care. Data were collected by in-depth interviews. Content analysis method was used to analyze the data. Results: Four themes emerged from the data: 1) lag of evaluation index; 2) limitations of evaluation content; 3) simplicity of evaluation method; 4) excessive emphasis on terminal quality. Conclusion: It is of great realistic significance to ameliorate nursing quality evaluation criteria, modify the evaluation content based on patient needs-oriented idea, adopt scientific evaluation method to evaluate nursing quality, and scientifically and reasonably draw horizontal comparisons of nursing quality between hospitals, as well as longitudinal comparisons of a hospital’s nursing quality. These methods mentioned above can all enhance a hospital’s core competitiveness and benefit more patients. PMID:25419427

  6. Preliminary Safety Design Report for Remote Handled Low-Level Waste Disposal Facility

    Energy Technology Data Exchange (ETDEWEB)

    Timothy Solack; Carol Mason

    2012-03-01

    A new onsite, remote-handled low-level waste disposal facility has been identified as the highest ranked alternative for providing continued, uninterrupted remote-handled low-level waste disposal for remote-handled low-level waste from the Idaho National Laboratory and for nuclear fuel processing activities at the Naval Reactors Facility. Historically, this type of waste has been disposed of at the Radioactive Waste Management Complex. Disposal of remote-handled low-level waste in concrete disposal vaults at the Radioactive Waste Management Complex will continue until the facility is full or until it must be closed in preparation for final remediation of the Subsurface Disposal Area (approximately at the end of Fiscal Year 2017). This preliminary safety design report supports the design of a proposed onsite remote-handled low-level waste disposal facility by providing an initial nuclear facility hazard categorization, by discussing site characteristics that impact accident analysis, by providing the facility and process information necessary to support the hazard analysis, by identifying and evaluating potential hazards for processes associated with onsite handling and disposal of remote-handled low-level waste, and by discussing the need for safety features that will become part of the facility design.

  7. Daily Encounter Cards-Evaluating the Quality of Documented Assessments.

    Science.gov (United States)

    Cheung, Warren J; Dudek, Nancy; Wood, Timothy J; Frank, Jason R

    2016-10-01

    Concerns over the quality of work-based assessment (WBA) completion has resulted in faculty development and rater training initiatives. Daily encounter cards (DECs) are a common form of WBA used in ambulatory care and shift work settings. A tool is needed to evaluate initiatives aimed at improving the quality of completion of this widely used form of WBA. The completed clinical evaluation report rating (CCERR) was designed to provide a measure of the quality of documented assessments on in-training evaluation reports. The purpose of this study was to provide validity evidence to support using the CCERR to assess the quality of DEC completion. Six experts in resident assessment grouped 60 DECs into 3 quality categories (high, average, and poor) based on how informative each DEC was for reporting judgments of the resident's performance. Eight supervisors (blinded to the expert groupings) scored the 10 most representative DECs in each group using the CCERR. Mean scores were compared to determine if the CCERR could discriminate based on DEC quality. Statistically significant differences in CCERR scores were observed between all quality groups ( P  evaluate DEC quality. It can serve as an outcome measure for studying interventions targeted at improving the quality of assessments documented on DECs.

  8. Internal education quality evaluation as a factor of development of engineering education quality in Russia

    OpenAIRE

    Shvindt Antoniy; Nikanorov Ivan

    2017-01-01

    In the paper, general approaches to evaluation of quality of engineering education in Russia, stated by expert community, are considered. The authors arrived at the conclusion that attention to internal evaluation mechanism of the education quality in Russian normative framework of higher education system is insufficient, as compared to European higher education practices. A pattern of involving the students in the internal evaluation of higher education quality is submitted to be a tool to d...

  9. New transport and handling contract

    CERN Multimedia

    SC Department

    2008-01-01

    A new transport and handling contract entered into force on 1.10.2008. As with the previous contract, the user interface is the internal transport/handling request form on EDH: https://edh.cern.ch/Document/TransportRequest/ To ensure that you receive the best possible service, we invite you to complete the various fields as accurately as possible and to include a mobile telephone number on which we can reach you. You can follow the progress of your request (schedule, completion) in the EDH request routing information. We remind you that the following deadlines apply: 48 hours for the transport of heavy goods (up to 8 tonnes) or simple handling operations 5 working days for crane operations, transport of extra-heavy goods, complex handling operations and combined transport and handling operations in the tunnel. For all enquiries, the number to contact remains unchanged: 72202. Heavy Handling Section TS-HE-HH 72672 - 160319

  10. Handling final storage of unreprocessed spent nuclear fuel

    International Nuclear Information System (INIS)

    1978-01-01

    The present second report from KBS describes how the safe final storage of spent unreprocessed nuclear fuel can be implemented. According to the Swedish Stipulation Law, the owner must specify in which form the waste is to be stored, how final storage is to be effected, how the waste is to be transported and all other aspects of fuel handling and storage which must be taken into consideration in judging whether the proposed final storage method can be considered to be absolutely safe and feasible. Thus, the description must go beyond general plans and sketches. The description is therefore relatively detailed, even concerning those parts which are less essential for evaluating the safety of the waste storage method. For those parts of the handling chain which are the same for both alternatives of the Stipulation Law, the reader is referred in some cases to the first report. Both of the alternatives of the Stipulation Law may be used in the future. Handling equipment and facilities for the two storage methods are so designed that a combination in the desired proportions is practically feasible. In this first part of the report are presented: premises and data, a description of the various steps of the handling procedure, a summary of dispersal processes and a safety analysis. (author)

  11. Painting for nuclear power stations and machinery and equipments according to quality assurance program of ANSI

    International Nuclear Information System (INIS)

    Fukuda, Shinzo; Tsuchiya, Yukikazu.

    1979-01-01

    Recently, painting for nuclear power stations is carried out with the paints made domestically, and these paints are tested and judged generally according to the items of performance evaluation decided by the American National Standard Institute. In Japan, there is no standard regarding the paints for nuclear power stations. Painting is very important process, and it is appropriate to introduce quality assurance program into it. In this paper, the contents of ANSI standard concerning the paints and painting for nuclear power stations are explained, and the outline of the painting of heat exchangers carried out in accordance with the quality assurance program in the Tamano Shipyard, Mitsui Shipbuilding and Engineering Co., Ltd., is described. The test items for evaluating the general performance of the paints, the testing method for evaluating the endurance at the time of an accident, the quality assurance for the paints used for the facilities handling radiation and others are explained. Various problems arise when the quality assurance program of ANSI is applied actually to painting. It is difficult to judge the quality of paints and painting with numerical values, and much efforts were required to establish the quality assurance organization. The conditions for painting, the handling of many documents, the measures to unsatisfactory painting and so on caused much difficulties. (Kako, I.)

  12. Internal quality control of PCR-based genotyping methods

    DEFF Research Database (Denmark)

    Bladbjerg, Else-Marie; Gram, Jørgen; Jespersen, Jørgen

    2002-01-01

    Internal quality control programmes for genetic analyses are needed. We have focused on quality control aspects of selected polymorphism analyses used in thrombosis research. DNA was isolated from EDTA-blood (n = 500) and analysed for 18 polymorphisms by polymerase chain reaction (PCR), i...... because of positive reagent blanks (controls (Control of data handling revealed 0.1% reading mistakes and 0.5% entry mistakes. Based on our experiences, we propose an internal quality control programme......, electrophoresis (analytical factors), result reading and entry into a database (post-analytical factors). Furthermore, we evaluated a procedure for result confirmation. Isolated DNA was of good quality (42 micrograms/ml blood, A260/A280 ratio > 1.75, negative DNAsis tests). Occasionally, results were reanalysed...

  13. Malzeme Taşıma Sistemi Alternatiflerinin Değerlendirilmesinde Bulanık-Promethee Yaklaşımı = Evaluating Material Handling System Alternatives Using Fuzzy-Promethee Approach

    Directory of Open Access Journals (Sweden)

    Bahadır GÜLSÜN

    2011-01-01

    Full Text Available Material handling system selection process has an important effect on productivity of manufacturing systems. Considering the importance of this process, it can be seen that there is a necessity to establish a systematic approach. In this study, to determine the best material handling system alternative, PROMETHEE approach is utilized. With the aim of taking into account the vagueness in the evaluation process and obtaining decision maker evaluations in an easier way with linguistic terms, fuzzy sets are utilized. To this end, a modified version of PROMETHEE is used. To foster the better understanding of the methodology, a real life application of a manufacturer is realized.

  14. Quality evaluation in distance undergraduate courses in Brazil

    Directory of Open Access Journals (Sweden)

    Carla Netto

    2015-01-01

    of distance-run undergraduate courses (D.Ed.. The data from the instruments were then processed according to Discourse Textual Analysis (DTA. The evaluation process for undergraduate distance education courses in the USA was evaluated by identifying those quality indicators adopted by international accreditation agencies. Based on the analysis of the evaluation process of distance undergraduate courses in Brazil, a further study was carried out about the results and impacts of the Brazilian system, especially the indicators used and the level of confidence that existed when measuring the quality of distance-based undergraduate courses. As a result of this research, our researchers observed there was a real need to establish a quality assurance benchmark in Brazil along these conceptual lines, namely one that represents quality in D.Ed. and includes the usage of indicators that reflect the excellence of the degree course that are offered. This level of excellence is assessed on the basis of the training, experience, knowledge and skills of the evaluators, as well as on clear, precise and transparent criteria for measuring the quality-based distance degree courses. On the other hand, it is also necessary to be equipped with a Bank of Evaluators – not only for those who work in this field, but also for a group of experts that is large enough to implement the Brazilian evaluation system in distance education programs.

  15. An effective quality model for evaluating mobile websites

    International Nuclear Information System (INIS)

    Hassan, W.U.; Nawaz, M.T.; Syed, T.H.; Naseem, A.

    2015-01-01

    The Evolution in Web development in recent years has caused emergence of new area of mobile computing, Mobile phone has been transformed into high speed processing device capable of doing the processes which were suppose to be run only on computer previously, Modem mobile phones now have capability to process data with greater speed then desktop systems and with the inclusion of 3G and 4G networks, mobile became the prime choice for users to send and receive data from any device. As a result, there is a major increase in mobile website need and development but due to uniqueness of mobile website usage as compared to desktop website, there is a need to focus on quality aspect of mobile website, So, to increase and preserve quality of mobile website, a quality model is required which has to be designed specifically to evaluate mobile website quality, To design a mobile website quality model, a survey based methodology is used to gather the information regarding website unique usage in mobile from different users. On the basis of this information, a mobile website quality model is presented which aims to evaluate the quality of mobile websites. In proposed model, some sub characteristics are designed to evaluate mobile websites in particular. The result is a proposed model aims to evaluate features of website which are important in context of its deployment and its usability in mobile platform. (author)

  16. Trends in Modern Exception Handling

    Directory of Open Access Journals (Sweden)

    Marcin Kuta

    2003-01-01

    Full Text Available Exception handling is nowadays a necessary component of error proof information systems. The paper presents overview of techniques and models of exception handling, problems connected with them and potential solutions. The aspects of implementation of propagation mechanisms and exception handling, their effect on semantics and general program efficiency are also taken into account. Presented mechanisms were adopted to modern programming languages. Considering design area, formal methods and formal verification of program properties we can notice exception handling mechanisms are weakly present what makes a field for future research.

  17. Design and Implementation of Company Tailored Automated Material Handling

    DEFF Research Database (Denmark)

    Langer, Gilad; Bilberg, Arne

    1996-01-01

    This article focuses on the problems of analysing automation of material handling systems in order to develop an efficient automated solution that is specifically tailored to the company. The research has resulted in development of new methods for evaluating factory automation from design...... to implementation. The goals of the research were to analyse and evaluate automation in order to obtain an advantageous combination of human and automated resources. The idea is to asses different solutions in a virtual environment, where experiments and analyses can be performed so that the company can justify...... for their application with computer aided information processing tools. The framework is named the "Automated Material Handling (AMH) Preference GuideLine". The research has been carried out in close co-operation with Danish and European industry, where implementations of automation can be referred to. It is our...

  18. Evaluation of Human Prehension Using Grasp Quality Measures

    Directory of Open Access Journals (Sweden)

    Beatriz León

    2012-10-01

    Full Text Available One of the main features of the human hand is its grasping ability. Robot grasping has been studied for years and different quality measures have been proposed to evaluate the stability and manipulability of grasps. Although the human hand is obviously more complex than robot hands, the methods used in robotics might be adopted to study the human grasp. The purpose of this work is to propose a set of measures that allow the evaluation of different aspects of the human grasp. The most common robotic grasp quality measures have been adapted to the evaluation of the human hand and a new quality measure – the fatigue index – is proposed in order to incorporate the biomechanical aspect into the evaluation. The minimum set of indices that allows the evaluation of the different aspects of the grasp is obtained from the analysis of a human prehension experiment.

  19. Evolution of a test article handling system for the SP-100 GES test

    International Nuclear Information System (INIS)

    Shen, E.J.; Schweiger, L.J.; Miller, W.C.; Gluck, R.; Davies, S.M.

    1987-01-01

    A simulated space environment test of a flight prototypic SP-100 reactor, control system, and flight shield will be conducted at the Hanford Engineering Development Laboratory (HEDL). The flight prototypic components and the supporting primary heat removal system are collectively known as the nuclear assembly test article (TA). The unique configuration and materials of fabrication for the Test Article require a specialized handling facility to support installation, maintenance, and final disposal operation. The test site operator, working in conjunction with the test article supplier, developed and evaluated several handling concepts resulting in the selection of a reference test article handling system. The development of the reference concept for the handling system is presented

  20. Study on Handing Process and Quality Degradation of Oil Palm Fresh Fruit Bunches (FFB)

    Science.gov (United States)

    Mat Sharif, Zainon Binti; Taib, Norhasnina Binti Mohd; Yusof, Mohd Sallehuddin Bin; Rahim, Mohammad Zulafif Bin; Tobi, Abdul Latif Bin Mohd; Othman, Mohd Syafiq Bin

    2017-05-01

    The main objective of this study is to determine the relationship between quality of oil palm fresh fruit bunches (FFB) and handling processes. The study employs exploratory and descriptive design, with quantitative approach and purposive sampling using self-administrated questionnaires, were obtained from 30 smallholder respondents from the Southern Region, Peninsular Malaysia. The study reveals that there was a convincing relationship between quality of oil palm fresh fruit bunches (FFB) and handling processes. The main handling process factors influencing quality of oil palm fresh fruit bunches (FFB) were harvesting activity and handling at the plantation area. As a result, it can be deduced that the handling process factors variable explains 82.80% of the variance that reflects the quality of oil palm fresh fruit bunches (FFB). The overall findings reveal that the handling process factors do play a significant role in the quality of oil palm fresh fruit bunches (FFB).

  1. Rethinking Educational Evaluation for Quality Educational Outcomes

    African Journals Online (AJOL)

    Rethinking Educational Evaluation for Quality Educational Outcomes. ... Educational Evaluation (EE) provides information for action by offering invaluable knowledge in terms of theoretical and practical ... AJOL African Journals Online.

  2. Simulation of the MRS receiving and handling facility

    International Nuclear Information System (INIS)

    Triplett, M.B.; Imhoff, C.H.; Hostick, C.J.

    1984-02-01

    Monitored retrievable storage (MRS) will be required to handle a large volume of spent fuel or high-level waste (HLW) in case of delays in repository deployment. The quantities of materials to be received and repackaged for storage far exceed the requirements of existing waste mangement facilities. A computer simulation model of the MRS receiving and handling (R and H) fcility has been constructed and used to evaluate design alternatives. Studies have identified processes or activities which may constrain throughput performance. In addition, the model has helped to assess design tradeoffs such as those to be made among improved process times, redundant service lines, and improved component availability. 1 reference, 5 figures

  3. Remote handling machines

    International Nuclear Information System (INIS)

    Sato, Shinri

    1985-01-01

    In nuclear power facilities, the management of radioactive wastes is made with its technology plus the automatic techniques. Under the radiation field, the maintenance or aid of such systems is important. To cope with this situation, MF-2 system, MF-3 system and a manipulator system as remote handling machines are described. MF-2 system consists of an MF-2 carrier truck, a control unit and a command trailer. It is capable of handling heavy-weight objects. The system is not by hydraulic but by electrical means. MF-3 system consists of a four-crawler truck and a manipulator. The truck is versatile in its posture by means of the four independent crawlers. The manipulator system is bilateral in operation, so that the delicate handling is made possible. (Mori, K.)

  4. Methods for handling uncertainty within pharmaceutical funding decisions

    Science.gov (United States)

    Stevenson, Matt; Tappenden, Paul; Squires, Hazel

    2014-01-01

    This article provides a position statement regarding decision making under uncertainty within the economic evaluation of pharmaceuticals, with a particular focus upon the National Institute for Health and Clinical Excellence context within England and Wales. This area is of importance as funding agencies have a finite budget from which to purchase a selection of competing health care interventions. The objective function generally used is that of maximising societal health with an explicit acknowledgement that there will be opportunity costs associated with purchasing a particular intervention. Three components of uncertainty are discussed within a pharmaceutical funding perspective: methodological uncertainty, parameter uncertainty and structural uncertainty, alongside a discussion of challenges that are particularly pertinent to health economic evaluation. The discipline has focused primarily on handling methodological and parameter uncertainty and a clear reference case has been developed for consistency across evaluations. However, uncertainties still remain. Less attention has been given to methods for handling structural uncertainty. The lack of adequate methods to explicitly incorporate this aspect of model development may result in the true uncertainty surrounding health care investment decisions being underestimated. Research in this area is ongoing as we review.

  5. Remote handling equipment for CANDU retubing

    International Nuclear Information System (INIS)

    Crawford, G.S.; Lowe, H.

    1993-01-01

    Numet Engineering Ltd. has designed and supplied remote handling equipment for Ontario Hydro's retubing operation of its CANDU reactors at the Bruce Nuclear Generating Station. This equipment consists of ''Retubing Tool Carriers'' an'' Worktables'' which operate remotely or manually at the reactor face. Together they function to transport tooling to and from the reactor face, to position and support tooling during retubing operations, and to deliver and retrieve fuel channels and channel components. This paper presents the fundamentals of the process and discusses the equipment supplied in terms of its design, manufacturing, components and controls, to meet the functional and quality requirements of Ontario Hydro's retubing process. (author)

  6. Combined application of Product Lifecycle and Software Configuration Management systems for ITER remote handling

    International Nuclear Information System (INIS)

    Muhammad, Ali; Esque, Salvador; Aha, Liisa; Mattila, Jouni; Siuko, Mikko; Vilenius, Matti; Jaervenpaeae, Jorma; Irving, Mike; Damiani, Carlo; Semeraro, Luigi

    2009-01-01

    The advantages of Product Lifecycle Management (PLM) systems are widely understood among the industry and hence a PLM system is already in use by International Thermonuclear Experimental Reactor (ITER) Organization (IO). However, with the increasing involvement of software in the development, the role of Software Configuration Management (SCM) systems have become equally important. The SCM systems can be useful to meet the higher demands on Safety Engineering (SE), Quality Assurance (QA), Validation and Verification (V and V) and Requirements Management (RM) of the developed software tools. In an experimental environment, such as ITER, the new remote handling requirements emerge frequently. This means the development of new tools or the modification of existing tools and the development of new remote handling procedures or the modification of existing remote handling procedures. PLM and SCM systems together can be of great advantage in the development and maintenance of such remote handling system. In this paper, we discuss how PLM and SCM systems can be integrated together and play their role during the development and maintenance of ITER remote handling system. We discuss the possibility to investigate such setup at DTP2 (Divertor Test Platform 2), which is the full scale mock-up facility to verify the ITER divertor remote handling and maintenance concepts.

  7. Quality management tool

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Tae Hun

    2011-09-15

    This book introduces basic conception of quality with characteristic, price, cost, and function, basic conception on quality management, introduction and operation of quality management, quality guaranteed and claim like handling of claim of goods, standards, and quality guaranteed method, basic tools of quality management such as Pareto diagram, characteristic diagram, cause-and-effect, fish born diagram check sheet histogram scatter diagram graph and stratification new seven tools of QC, quality deployment function and measurement system.

  8. Quality management tool

    International Nuclear Information System (INIS)

    Lee, Tae Hun

    2011-09-01

    This book introduces basic conception of quality with characteristic, price, cost, and function, basic conception on quality management, introduction and operation of quality management, quality guaranteed and claim like handling of claim of goods, standards, and quality guaranteed method, basic tools of quality management such as Pareto diagram, characteristic diagram, cause-and-effect, fish born diagram check sheet histogram scatter diagram graph and stratification new seven tools of QC, quality deployment function and measurement system.

  9. Nondestructive quality evaluation technology of agricultural products

    International Nuclear Information System (INIS)

    Noh, Sang Ha

    1997-01-01

    Quality evaluation of agricultural products has been interested to many researchers for many years and as the result, several nondestructive techniques and so many papers have been reported for quality evaluation of agricultural products. These nondestructive techniques are based on the detection of mechanical, optical, electrical, electro-magnetical, dielectric and vibrational properties of agricultural products that are well correlated with certain quality factors of the products such as color, shape, firmness, sugar content, external or internal defects, moisture content, etc. The sophistication of nondestructive methods has evolved rapidly with modem technologies. In this paper an emphasis was put on reviewing some of those papers and techniques which could be led to on-line measurement for practical use.

  10. Safety of Cargo Aircraft Handling Procedure

    Directory of Open Access Journals (Sweden)

    Daniel Hlavatý

    2017-07-01

    Full Text Available The aim of this paper is to get acquainted with the ways how to improve the safety management system during cargo aircraft handling. The first chapter is dedicated to general information about air cargo transportation. This includes the history or types of cargo aircraft handling, but also the means of handling. The second part is focused on detailed description of cargo aircraft handling, including a description of activities that are performed before and after handling. The following part of this paper covers a theoretical interpretation of safety, safety indicators and legislative provisions related to the safety of cargo aircraft handling. The fourth part of this paper analyzes the fault trees of events which might occur during handling. The factors found by this analysis are compared with safety reports of FedEx. Based on the comparison, there is a proposal on how to improve the safety management in this transportation company.

  11. EVALUATION OF HEALTH CARE QUALITY

    Directory of Open Access Journals (Sweden)

    Zlatko Fras

    2002-12-01

    Full Text Available Background. It is possible to evaluate quality characteristics of different aspects of health care by many different measures. For these purposes, in various countries all over the world authorised institutions and/or agencies developed number of methodological accessories, criteria and tools for selection of more or less appropriately and optimally defined criteria and indicators of quality clinical performance.Conclusions. Recently we have started with activities for gradual introduction of systematic monitoring, assessment and improvement of quality of health care in Slovenia as well. One of the key prerequisites for selection of valid, practicable, efficient and reliable quality indicators is the establishment of continuous and methodologically appropriate system of development and implementation of evidence-based clinical practice guidelines. We started this process within the framework of national Health Sector Management Project, where all potential key stakeholders from health care sector participated. Also the project on Quality in Health Care in Slovenia, started, leaded and performed by the Medical Chamber of Slovenia, represents one of the important parallel starting steps towards assurance of reliable data on development/establishment of appropriate set of quality indicators and standards of health care in our country.

  12. Daily Encounter Cards—Evaluating the Quality of Documented Assessments

    Science.gov (United States)

    Cheung, Warren J.; Dudek, Nancy; Wood, Timothy J.; Frank, Jason R.

    2016-01-01

    ABSTRACT Background  Concerns over the quality of work-based assessment (WBA) completion has resulted in faculty development and rater training initiatives. Daily encounter cards (DECs) are a common form of WBA used in ambulatory care and shift work settings. A tool is needed to evaluate initiatives aimed at improving the quality of completion of this widely used form of WBA. Objective  The completed clinical evaluation report rating (CCERR) was designed to provide a measure of the quality of documented assessments on in-training evaluation reports. The purpose of this study was to provide validity evidence to support using the CCERR to assess the quality of DEC completion. Methods  Six experts in resident assessment grouped 60 DECs into 3 quality categories (high, average, and poor) based on how informative each DEC was for reporting judgments of the resident's performance. Eight supervisors (blinded to the expert groupings) scored the 10 most representative DECs in each group using the CCERR. Mean scores were compared to determine if the CCERR could discriminate based on DEC quality. Results  Statistically significant differences in CCERR scores were observed between all quality groups (P < .001). A generalizability analysis demonstrated the majority of score variation was due to differences in DECs. The reliability with a single rater was 0.95. Conclusions  The CCERR is a reliable and valid tool to evaluate DEC quality. It can serve as an outcome measure for studying interventions targeted at improving the quality of assessments documented on DECs. PMID:27777675

  13. Headache service quality: evaluation of quality indicators in 14 specialist-care centres.

    Science.gov (United States)

    Schramm, Sara; Uluduz, Derya; Gouveia, Raquel Gil; Jensen, Rigmor; Siva, Aksel; Uygunoglu, Ugur; Gvantsa, Giorgadze; Mania, Maka; Braschinsky, Mark; Filatova, Elena; Latysheva, Nina; Osipova, Vera; Skorobogatykh, Kirill; Azimova, Julia; Straube, Andreas; Eren, Ozan Emre; Martelletti, Paolo; De Angelis, Valerio; Negro, Andrea; Linde, Mattias; Hagen, Knut; Radojicic, Aleksandra; Zidverc-Trajkovic, Jasna; Podgorac, Ana; Paemeleire, Koen; De Pue, Annelien; Lampl, Christian; Steiner, Timothy J; Katsarava, Zaza

    2016-12-01

    The study was a collaboration between Lifting The Burden (LTB) and the European Headache Federation (EHF). Its aim was to evaluate the implementation of quality indicators for headache care Europe-wide in specialist headache centres (level-3 according to the EHF/LTB standard). Employing previously-developed instruments in 14 such centres, we made enquiries, in each, of health-care providers (doctors, nurses, psychologists, physiotherapists) and 50 patients, and analysed the medical records of 50 other patients. Enquiries were in 9 domains: diagnostic accuracy, individualized management, referral pathways, patient's education and reassurance, convenience and comfort, patient's satisfaction, equity and efficiency of the headache care, outcome assessment and safety. Our study showed that highly experienced headache centres treated their patients in general very well. The centres were content with their work and their patients were content with their treatment. Including disability and quality-of-life evaluations in clinical assessments, and protocols regarding safety, proved problematic: better standards for these are needed. Some centres had problems with follow-up: many specialised centres operated in one-touch systems, without possibility of controlling long-term management or the success of treatments dependent on this. This first Europe-wide quality study showed that the quality indicators were workable in specialist care. They demonstrated common trends, producing evidence of what is majority practice. They also uncovered deficits that might be remedied in order to improve quality. They offer the means of setting benchmarks against which service quality may be judged. The next step is to take the evaluation process into non-specialist care (EHF/LTB levels 1 and 2).

  14. Using accelerometry to quantify prey attack and handling behaviours in piscivorous pike Esox lucius

    DEFF Research Database (Denmark)

    Deurs, Mikael van; Andersson, A.; Vinterstare, J.

    2017-01-01

    Accelerometer technology was used to evaluate behaviours in the teleost ambush predator pike Esox lucius foraging on crucian carp Carassius carassius. Automated rule-based estimates of prey-size determined handling time were obtained and are compared with video-recorded behaviours. Solutions to t...... attachment and the limitations imposed by battery-time and data-logging capacities are evaluated......Accelerometer technology was used to evaluate behaviours in the teleost ambush predator pike Esox lucius foraging on crucian carp Carassius carassius. Automated rule-based estimates of prey-size determined handling time were obtained and are compared with video-recorded behaviours. Solutions to tag...

  15. Ergonomics and patient handling.

    Science.gov (United States)

    McCoskey, Kelsey L

    2007-11-01

    This study aimed to describe patient-handling demands in inpatient units during a 24-hour period at a military health care facility. A 1-day total population survey described the diverse nature and impact of patient-handling tasks relative to a variety of nursing care units, patient characteristics, and transfer equipment. Productivity baselines were established based on patient dependency, physical exertion, type of transfer, and time spent performing the transfer. Descriptions of the physiological effect of transfers on staff based on patient, transfer, and staff characteristics were developed. Nursing staff response to surveys demonstrated how patient-handling demands are impacted by the staff's physical exertion and level of patient dependency. The findings of this study describe the types of transfers occurring in these inpatient units and the physical exertion and time requirements for these transfers. This description may guide selection of the most appropriate and cost-effective patient-handling equipment required for specific units and patients.

  16. Construction and operation of replacement hazardous waste handling facility at Lawrence Berkeley Laboratory. Environmental Assessment

    Energy Technology Data Exchange (ETDEWEB)

    1992-09-01

    The US Department of Energy (DOE) has prepared an environmental assessment (EA), DOE/EA-0423, for the construction and operation of a replacement hazardous waste handling facility (HWHF) and decontamination of the existing HWHF at Lawrence Berkeley Laboratory (LBL), Berkeley, California. The proposed facility would replace several older buildings and cargo containers currently being used for waste handling activities and consolidate the LBL`s existing waste handling activities in one location. The nature of the waste handling activities and the waste volume and characteristics would not change as a result of construction of the new facility. Based on the analysis in the EA, DOE has determined that the proposed action would not constitute a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act (NEPA) of 1969, 42 USC. 4321 et seq. Therefore, an environmental impact statement is not required.

  17. Equipment for the handling of thorium materials

    International Nuclear Information System (INIS)

    Heisler, S.W. Jr.; Mihalovich, G.S.

    1988-01-01

    The Feed Materials Production Center (FMPC) is the United States Department of Energy's storage facility for thorium. FMPC thorium handling and overpacking projects ensure the continued safe handling and storage of the thorium inventory until final disposition of the materials is determined and implemented. The handling and overpacking of the thorium materials requires the design of a system that utilizes remote handling and overpacking equipment not currently utilized at the FMPC in the handling of uranium materials. The use of remote equipment significantly reduces radiation exposure to personnel during the handling and overpacking efforts. The design system combines existing technologies from the nuclear industry, the materials processing and handling industry and the mining industry. The designed system consists of a modified fork lift truck for the transport of thorium containers, automated equipment for material identification and inventory control, and remote handling and overpacking equipment for material identification and inventory control, and remote handling and overpacking equipment for repackaging of the thorium materials

  18. Adaptive and energy efficient SMA-based handling systems

    Science.gov (United States)

    Motzki, P.; Kunze, J.; Holz, B.; York, A.; Seelecke, S.

    2015-04-01

    Shape Memory Alloys (SMA's) are known as actuators with very high energy density. This fact allows for the construction of very light weight and energy-efficient systems. In the field of material handling and automated assembly process, the avoidance of big moments of inertia in robots and kinematic units is essential. High inertial forces require bigger and stronger robot actuators and thus higher energy consumption and costs. For material handling in assembly processes, many different individual grippers for various work piece geometries are used. If one robot has to handle different work pieces, the gripper has to be exchanged and the assembly process is interrupted, which results in higher costs. In this paper, the advantages of using high energy density Shape Memory Alloy actuators in applications of material-handling and gripping-technology are explored. In particular, light-weight SMA actuated prototypes of an adaptive end-effector and a vacuum-gripper are constructed via rapid-prototyping and evaluated. The adaptive end-effector can change its configuration according to the work piece geometry and allows the handling of multiple different shaped objects without exchanging gripper tooling. SMA wires are used to move four independent arms, each arm adds one degree of freedom to the kinematic unit. At the tips of these end-effector arms, SMA-activated suction cups can be installed. The suction cup prototypes are developed separately. The flexible membranes of these suction cups are pulled up by SMA wires and thus a vacuum is created between the membrane and the work piece surface. The self-sensing ability of the SMA wires are used in both prototypes for monitoring their actuation.

  19. Safe Patient Handling and Mobility: Development and Implementation of a Large-Scale Education Program.

    Science.gov (United States)

    Lee, Corinne; Knight, Suzanne W; Smith, Sharon L; Nagle, Dorothy J; DeVries, Lori

    This article addresses the development, implementation, and evaluation of an education program for safe patient handling and mobility at a large academic medical center. The ultimate goal of the program was to increase safety during patient mobility/transfer and reduce nursing staff injury from lifting/pulling. This comprehensive program was designed on the basis of the principles of prework, application, and support at the point of care. A combination of online learning, demonstration, skill evaluation, and coaching at the point of care was used to achieve the goal. Specific roles and responsibilities were developed to facilitate implementation. It took 17 master trainers, 88 certified trainers, 176 unit-based trainers, and 98 coaches to put 3706 nurses and nursing assistants through the program. Evaluations indicated both an increase in knowledge about safe patient handling and an increased ability to safely mobilize patients. The challenge now is sustainability of safe patient-handling practices and the growth and development of trainers and coaches.

  20. How to Handle Abuse

    Science.gov (United States)

    ... Handle Abuse KidsHealth / For Kids / How to Handle Abuse What's in this article? Tell Right Away How Do You Know Something Is Abuse? ... babysitter, teacher, coach, or a bigger kid. Child abuse can happen anywhere — at ... building. Tell Right Away A kid who is being seriously hurt ...

  1. Waste Handling Building Conceptual Study

    International Nuclear Information System (INIS)

    G.W. Rowe

    2000-01-01

    The objective of the ''Waste Handling Building Conceptual Study'' is to develop proposed design requirements for the repository Waste Handling System in sufficient detail to allow the surface facility design to proceed to the License Application effort if the proposed requirements are approved by DOE. Proposed requirements were developed to further refine waste handling facility performance characteristics and design constraints with an emphasis on supporting modular construction, minimizing fuel inventory, and optimizing facility maintainability and dry handling operations. To meet this objective, this study attempts to provide an alternative design to the Site Recommendation design that is flexible, simple, reliable, and can be constructed in phases. The design concept will be input to the ''Modular Design/Construction and Operation Options Report'', which will address the overall program objectives and direction, including options and issues associated with transportation, the subsurface facility, and Total System Life Cycle Cost. This study (herein) is limited to the Waste Handling System and associated fuel staging system

  2. Practices of Handling

    DEFF Research Database (Denmark)

    Ræbild, Ulla

    to touch, pick up, carry, or feel with the hands. Figuratively it is to manage, deal with, direct, train, or control. Additionally, as a noun, a handle is something by which we grasp or open up something. Lastly, handle also has a Nordic root, here meaning to trade, bargain or deal. Together all four...... meanings seem to merge in the fashion design process, thus opening up for an embodied engagement with matter that entails direction giving, organizational management and negotiation. By seeing processes of handling as a key fashion methodological practice, it is possible to divert the discourse away from...... introduces four ways whereby fashion designers apply their own bodies as tools for design; a) re-activating past garment-design experiences, b) testing present garment-design experiences c) probing for new garment-design experiences and d) design of future garment experiences by body proxy. The paper...

  3. Evaluation of pesticide safety measures adopted by potato farmers ...

    African Journals Online (AJOL)

    In order to increase productivity and quality, farmers use pesticides and other agrochemicals. These pesticides if improperly handled impact negatively on the health of the users. The objective of the study was to evaluate the pesticide safety measures adopted by potato farmers in Chebiemit Division of Elgeyo/Marakwet ...

  4. Development of nuclear fuel cycle remote handling technology

    International Nuclear Information System (INIS)

    Kim, K. H.; Park, B. S.; Kim, S. H.

    2012-04-01

    This report presents the development of remote handling systems and remote equipment for use in the pyprocessing verification at the PRIDE (PyRoprocess Integrated inactive Demonstration facility). There are four areas conducted in this work. In first area, the prototypes of an engineering-scale high-throughput decladding voloxidizer which is capable of separating spent fuel rod-cuts into hulls and powder and collecting them separately, and an automatic equipment which is capable of collecting residual powder remaining on separated hulls were developed. In second area, a servo-manipulator system was developed to operate and maintain pyroprocess equipment located at the argon cell of the PRIDE in a remote manner. A servo-manipulator with dual arm that is mounted on the lower part of a bridge transporter will be installed on the ceiling of the in-cell and can travel the length of the ceiling. In third area, a digital mock-up and a remote handling evaluation mock-up were constructed to evaluate the pyroprocess equipments from the in-cell arrangements, remote operability and maintainability viewpoint before they are installed in the PRIDE. In last area, a base technology for remote automation of integrated pyroprocess was developed. The developed decladding voloxidizer and automatic equipment will be utilized in the development of a head-end process for pyroprocessing. In addition, the developed servo-manipulator will be used for remote operation and maintenance of the pyroprocess equipments in the PRIDE. The constructed digital mock-up and remote handling evaluation mock-up will be also used to verify and improve the pyroprocess equipments for the PRIDE application. Moreover, these remote technologies described above can be directly used in the PRIDE and applied for the KAPF (Korea Advanced Pyroprocess Facility) development

  5. Influence of Handling Practices on Material Recovery from Residential Solid Waste

    Directory of Open Access Journals (Sweden)

    Jairo F. Pereira

    2010-07-01

    Full Text Available Material recovery from municipal solid waste (MSW is becoming widely adopted in several developing countries. Residential solid waste is one of the most important components of MSW and the handling practices of the MSW by the generators have a major impact on the quality and quantity of the materials for recovery. This article analyzes the generation and composition of residential solid waste and the handling practices by users in three municipalities in Colombia that have a solid waste management plant (SWMP. The findings show that, although there are significant amounts of useful materials, their handling of the materials as “garbage”, the low recognition of recovery work, and the inadequate storage and source management practices, affect material recovery and the operation of SWMPs. These results may be taken as a reference for this type of municipality, because the solid waste management system and the type of operation of the SWMPs analyzed is similar to all of the SWMPs in the country as well as in other countries in the region.

  6. Radioisotope handling facilities and automation of radioisotope production

    International Nuclear Information System (INIS)

    2004-12-01

    If a survey is made of the advances in radioisotope handling facilities, as well as the technical conditions and equipment used for radioisotope production, it can be observed that no fundamental changes in the design principles and technical conditions of conventional manufacture have happened over the last several years. Recent developments are mainly based on previous experience aimed at providing safer and more reliable operations, more sophisticated maintenance technology and radioactive waste disposal. In addition to the above observation, significant improvements have been made in the production conditions of radioisotopes intended for medical use, by establishing aseptic conditions with clean areas and isolators, as well as by introducing quality assurance as governing principle in the production of pharmaceutical grade radioactive products. Requirements of the good manufacturing practice (GMP) are increasingly complied with by improving the technical and organizational conditions, as well as data registration and documentation. Technical conditions required for the aseptic production of pharmaceuticals and those required for radioactive materials conflicting in some aspects are because of the contrasting contamination mechanisms and due consideration of the radiation safety. These can be resolved by combining protection methods developed for pharmaceuticals and radioactive materials, with the necessary compromise in some cases. Automation serves to decrease the radiation dose to the operator and environment as well as to ensure more reliable and precise radiochemical processing. Automation has mainly been introduced in the production of sealed sources and PET radiopharmaceuticals. PC controlled technologies ensure high reliability for the production and product quality, whilst providing automatic data acquisition and registration required by quality assurance. PC control is also useful in the operation of measuring instruments and in devices used for

  7. Airline service quality evaluation: A review on concepts and models

    Directory of Open Access Journals (Sweden)

    Navid Haghighat

    2017-12-01

    Full Text Available This paper reviews different major service quality concept and models which led to great developments in evaluating service quality with focusing on improvement process of the models through discussing criticisms of each model. Criticisms against these models are discussed to clarify development steps of newer models which led to the improvement of airline service quality models. The precise and accurate evaluation of service quality needs utilizing a reliable concept with comprehensive criteria and effective measurement techniques as the fundamentals of a valuable framework. In this paper, service quality models improvement is described based on three major service quality concepts, the disconfirmation, performance and hierarchical concepts which are developed subsequently. Reviewing various criteria and different measurement techniques such a statistical analysis and multi-criteria decision making assist researchers to have a clear understanding of the development of the evaluation framework in the airline industry. This study aims at promoting reliable frameworks for evaluating airline service quality in different countries and societies due to economic, cultural and social aspects of each society.

  8. SRV-automatic handling device

    International Nuclear Information System (INIS)

    Yamada, Koji

    1987-01-01

    Automatic handling device for the steam relief valves (SRV's) is developed in order to achieve a decrease in exposure of workers, increase in availability factor, improvement in reliability, improvement in safety of operation, and labor saving. A survey is made during a periodical inspection to examine the actual SVR handling operation. An SRV automatic handling device consists of four components: conveyor, armed conveyor, lifting machine, and control/monitoring system. The conveyor is so designed that the existing I-rail installed in the containment vessel can be used without any modification. This is employed for conveying an SRV along the rail. The armed conveyor, designed for a box rail, is used for an SRV installed away from the rail. By using the lifting machine, an SRV installed away from the I-rail is brought to a spot just below the rail so that the SRV can be transferred by the conveyor. The control/monitoring system consists of a control computer, operation panel, TV monitor and annunciator. The SRV handling device is operated by remote control from a control room. A trial equipment is constructed and performance/function testing is carried out using actual SRV's. As a result, is it shown that the SRV handling device requires only two operators to serve satisfactorily. The required time for removal and replacement of one SRV is about 10 minutes. (Nogami, K.)

  9. A METHOD FOR IMPROVEMENT OF OBJECTIVITY OF E-SERVICE QUALITY EVALUATION

    Directory of Open Access Journals (Sweden)

    Renata Mekovec

    2007-12-01

    Full Text Available Measurement and improvement of e-service quality is important for sustaining competitive advantage of an e-commerce web site. A number of e-service quality measures have recently been developed that predominantly rely on the subjective evaluation of diverse quality attributes. To increase the objectivity of e-service quality measurement a recently developed measure of e-service quality has been adapted in a way that replaces its Likert type scales for evaluation of specific attributes with check-lists that include specific observable elements for appraisal and a scoring procedure. The consistency of scoring with this adaptation of an e-service quality measure was investigated in comparison to the use of the standard measure with Likert type scales and by the use of untrained and trained evaluators. The results of the empirical evaluation indicate a greater inter-rater consistency when the adapted/objective measure is used for evaluation of the efficiency dimension of e-service quality.

  10. Differences in Muscle Activity During Cable Resistance Training Are Influenced by Variations in Handle Types.

    Science.gov (United States)

    Rendos, Nicole K; Heredia Vargas, Héctor M; Alipio, Taislaine C; Regis, Rebeca C; Romero, Matthew A; Signorile, Joseph F

    2016-07-01

    Rendos, NK, Heredia Vargas, HM, Alipio, TC, Regis, RC, Romero, MA, and Signorile, JF. Differences in muscle activity during cable resistance training are influenced by variations in handle types. J Strength Cond Res 30(7): 2001-2009, 2016-There has been a recent resurgence in the use of cable machines for resistance training allowing movements that more effectively simulate daily activities and sports-specific movements. By necessity, these devices require a machine/human interface through some type of handle. Considerable data from material handling, industrial engineering, and exercise training studies indicate that handle qualities, especially size and shape, can significantly influence force production and muscular activity, particularly of the forearm muscles, which affect the critical link in activities that require object manipulation. The purpose for this study was to examine the influence of three different handle conditions: standard handle (StandH), ball handle with the cable between the index and middle fingers (BallIM), and ball handle with the cable between the middle and ring fingers (BallMR), on activity levels (rmsEMG) of the triceps brachii lateral and long heads (TriHLat, TriHLong), brachioradialis (BR), flexor carpi radialis (FCR), extensor carpi ulnaris, and extensor digitorum (ED) during eight repetitions of standing triceps pushdown performed from 90° to 0° elbow flexion at 1.5 s per contractile stage. Handle order was randomized. No significant differences were seen for triceps or BR rmsEMG across handle conditions; however, relative patterns of activation did vary for the forearm muscles by handle condition, with more coordinated activation levels for the FCR and ED during the ball handle conditions. In addition, the rmsEMG for the ED was significantly higher during the BallIM than any other condition and during the BallMR than the StandH. These results indicate that the use of ball handles with the cable passing between different fingers

  11. Grain Handling and Storage.

    Science.gov (United States)

    Harris, Troy G.; Minor, John

    This text for a secondary- or postecondary-level course in grain handling and storage contains ten chapters. Chapter titles are (1) Introduction to Grain Handling and Storage, (2) Elevator Safety, (3) Grain Grading and Seed Identification, (4) Moisture Control, (5) Insect and Rodent Control, (6) Grain Inventory Control, (7) Elevator Maintenance,…

  12. Current status of quality evaluation of nursing care through director review and reflection from the Nursing Quality Control Centers

    OpenAIRE

    Duan, Xia; Shi, Yan

    2014-01-01

    Background: The quality evaluation of nursing care is a key link in medical quality management. It is important and worth studying for the nursing supervisors to know the disadvantages during the process of quality evaluation of nursing care and then to improve the whole nursing quality. This study was to provide director insight on the current status of quality evaluation of nursing care from Nursing Quality Control Centers (NQCCs). Material and Methods: This qualitative study used a sample ...

  13. Changes in quality of goat meat after alterations in animal Handling - doi:10.5020/18061230.2007.p33

    Directory of Open Access Journals (Sweden)

    Frederico José Beserra

    2012-01-01

    Full Text Available This study aimed at evaluating the effect of animal handling, consisting in castration and cashew nut diet supplementation, on the cholesterol content and percentage composition of the muscles that constitute the leg meat cut from crossbred goats, grown in Ceará State. A case experimental design was applied with twenty male-animals with 5-6 months age and mean weight of 12 Kg, randomly divided in two groups of castrated (10 and intact (10 animals. In individual bays, they received during 5 months, two food regimen based on dried elephant grass (Pennisetum purpureum and a standard isoproteic ration (corn and soy oil, one of them with the addition of 13% cashew nut bran (CNB, forming four sub-groups: A1 (intact with no CNB supplemented diet; A2 (intact with CNB supplemented diet; B1 (castrated with no CNB supplemented diet and B2 (castrated with CNB supplemented diet. The castration associated with the CNB supplementation increased the meat’s fat yield from 1.16% to 3.57% and the cholesterol content from 36.47 mg/100g to 62.30 mg/100g. The ash yield decreased from 1.14% to 1.04%. The castration isolated only reduced moisture yield from 75.98% on sub-group A2 to 74.19% on sub-group B2. In intact animals that fed diet supplemented with CNB the protein decreased from 20.58% to 18.85% (P < 0.05 (sub-groups A1 and A2. The increased cholesterol content was highly correlated with the increase of the fat (93% In conclusion, these results showed that the combined use of castration and cashew nut bran (13% diet negatively influenced the dietetic and nutritional quality of goat leg meat.

  14. TRANSPORT/HANDLING REQUESTS

    CERN Multimedia

    Groupe ST/HM

    2002-01-01

    A new EDH document entitled 'Transport/Handling Request' will be in operation as of Monday, 11th February 2002, when the corresponding icon will be accessible from the EDH desktop, together with the application instructions. This EDH form will replace the paper-format transport/handling request form for all activities involving the transport of equipment and materials. However, the paper form will still be used for all vehicle-hire requests. The introduction of the EDH transport/handling request form is accompanied by the establishment of the following time limits for the various services concerned: 24 hours for the removal of office items, 48 hours for the transport of heavy items (of up to 6 metric tons and of standard road width), 5 working days for a crane operation, extra-heavy transport operation or complete removal, 5 working days for all transport operations relating to LHC installation. ST/HM Group, Logistics Section Tel: 72672 - 72202

  15. Single-case synthesis tools I: Comparing tools to evaluate SCD quality and rigor.

    Science.gov (United States)

    Zimmerman, Kathleen N; Ledford, Jennifer R; Severini, Katherine E; Pustejovsky, James E; Barton, Erin E; Lloyd, Blair P

    2018-03-03

    Tools for evaluating the quality and rigor of single case research designs (SCD) are often used when conducting SCD syntheses. Preferred components include evaluations of design features related to the internal validity of SCD to obtain quality and/or rigor ratings. Three tools for evaluating the quality and rigor of SCD (Council for Exceptional Children, What Works Clearinghouse, and Single-Case Analysis and Design Framework) were compared to determine if conclusions regarding the effectiveness of antecedent sensory-based interventions for young children changed based on choice of quality evaluation tool. Evaluation of SCD quality differed across tools, suggesting selection of quality evaluation tools impacts evaluation findings. Suggestions for selecting an appropriate quality and rigor assessment tool are provided and across-tool conclusions are drawn regarding the quality and rigor of studies. Finally, authors provide guidance for using quality evaluations in conjunction with outcome analyses when conducting syntheses of interventions evaluated in the context of SCD. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Fast Evaluation of Segmentation Quality with Parallel Computing

    Directory of Open Access Journals (Sweden)

    Henry Cruz

    2017-01-01

    Full Text Available In digital image processing and computer vision, a fairly frequent task is the performance comparison of different algorithms on enormous image databases. This task is usually time-consuming and tedious, such that any kind of tool to simplify this work is welcome. To achieve an efficient and more practical handling of a normally tedious evaluation, we implemented the automatic detection system, with the help of MATLAB®’s Parallel Computing Toolbox™. The key parts of the system have been parallelized to achieve simultaneous execution and analysis of segmentation algorithms on the one hand and the evaluation of detection accuracy for the nonforested regions, such as a study case, on the other hand. As a positive side effect, CPU usage was reduced and processing time was significantly decreased by 68.54% compared to sequential processing (i.e., executing the system with each algorithm one by one.

  17. Evaluation of the quality of CR mammography images in Chugoku Rosai Hospital. Visual evaluation and digital evaluation

    International Nuclear Information System (INIS)

    Makihata, Hiroshi; Fukuda, Tomoya; Aomori, Masaji; Hara, Shinji

    2005-01-01

    New mammography system (50-micrometer system) composed of Fuji computed tomography (FCR) both sides IP, 5000MA and dry imager was introduced in the Department of Physical Checkup of Chugoku Rosai Hospital in 2003. We performed visual evaluation and digital evaluation using 50-micrometer system in accordance with (the quality control guidance of) Non-Profit Organization the Central Committee on Quality Control of Mammographic Screening. In visual evaluation using RMI156 phantom the system cleared the quality control guidance about a fiber, calcification, and masses. On step phantom, it passed about 10 steps, masses, and calcifications. Since a success standard was not announced officially, the performance in digital evaluation cannot be judged and only the result is presented. In digital evaluation, signal-to-noise ratio (SNR) is 14.9, root of mean squares (RMS) is 32.9, SNRC is 16.4, SNRT is 3.65. This system image has high sharpness and is considered from the result in visual evaluation to have the ability of offering images with a high degree of information. (author)

  18. The effect of water supply, handling and usage on water quality in relation to health indices in a developing community in South Africa.

    Science.gov (United States)

    Genthe, B; Strauss, N; Vundule, C; Maforah, F; Seager, J

    1995-09-01

    This study examined the relationship between the quality of water consumed by people in a developing community in South Africa, and health outcomes for diarrhea. Water sources included no formal water supply, communal taps used by over 100 people, outdoor taps on individual plots, and indoor taps. The aim of this 3-year study was to determine water quality at point of collection, to examine patterns of water usage, and to determine the health consequences. This was a case control study and epidemiological assessment. The sample included over 300 households. Cases included pre-school children with severe diarrhea who visited a health facility in the study area. Interviews were conducted to determine hygiene, sanitation, education, and socioeconomic information. Controls of similar age and type of water supply were obtained from neighborhoods in the study area. Findings indicate that water, based on microbiological assay, was of good quality and complied with the South African Bureau of Standards. Water was significantly more contaminated after handling and storage compared to point of source. Cases and controls had equally poor water quality after collection and storage. Control indoor cases had higher levels of E. coli. There was a strong association between diarrhea and the attendance at a day care center. Increased risk of diarrhea was associated with poor kitchen hygiene and low levels of knowledge about hygiene and diarrhea prevention. Communal tap facilities had lower water quality than private taps.

  19. [Methodological quality and reporting quality evaluation of randomized controlled trials published in China Journal of Chinese Materia Medica].

    Science.gov (United States)

    Yu, Dan-Dan; Xie, Yan-Ming; Liao, Xing; Zhi, Ying-Jie; Jiang, Jun-Jie; Chen, Wei

    2018-02-01

    To evaluate the methodological quality and reporting quality of randomized controlled trials(RCTs) published in China Journal of Chinese Materia Medica, we searched CNKI and China Journal of Chinese Materia webpage to collect RCTs since the establishment of the magazine. The Cochrane risk of bias assessment tool was used to evaluate the methodological quality of RCTs. The CONSORT 2010 list was adopted as reporting quality evaluating tool. Finally, 184 RCTs were included and evaluated methodologically, of which 97 RCTs were evaluated with reporting quality. For the methodological evaluating, 62 trials(33.70%) reported the random sequence generation; 9(4.89%) trials reported the allocation concealment; 25(13.59%) trials adopted the method of blinding; 30(16.30%) trials reported the number of patients withdrawing, dropping out and those lost to follow-up;2 trials (1.09%) reported trial registration and none of the trial reported the trial protocol; only 8(4.35%) trials reported the sample size estimation in details. For reporting quality appraising, 3 reporting items of 25 items were evaluated with high-quality,including: abstract, participants qualified criteria, and statistical methods; 4 reporting items with medium-quality, including purpose, intervention, random sequence method, and data collection of sites and locations; 9 items with low-quality reporting items including title, backgrounds, random sequence types, allocation concealment, blindness, recruitment of subjects, baseline data, harms, and funding;the rest of items were of extremely low quality(the compliance rate of reporting item<10%). On the whole, the methodological and reporting quality of RCTs published in the magazine are generally low. Further improvement in both methodological and reporting quality for RCTs of traditional Chinese medicine are warranted. It is recommended that the international standards and procedures for RCT design should be strictly followed to conduct high-quality trials

  20. Arrival condition of spent fuel after storage, handling, and transportation

    International Nuclear Information System (INIS)

    Bailey, W.J.; Pankaskie, P.J.; Langstaff, D.C.; Gilbert, E.R.; Rising, K.H.; Schreiber, R.E.

    1982-11-01

    This report presents the results of a study conducted to determine the probable arrival condition of spent light-water reactor (LWR) fuel after handling and interim storage in spent fuel storage pools and subsequent handling and accident-free transport operations under normal or slightly abnormal conditions. The objective of this study was to provide information on the expected condition of spent LWR fuel upon arrival at interim storage or fuel reprocessing facilities or at disposal facilities if the fuel is declared a waste. Results of a literature survey and data evaluation effort are discussed. Preliminary threshold limits for storing, handling, and transporting unconsolidated spent LWR fuel are presented. The difficulty in trying to anticipate the amount of corrosion products (crud) that may be on spent fuel in future shipments is also discussed, and potential areas for future work are listed. 95 references, 3 figures, 17 tables

  1. Certification Plan, Radioactive Mixed Waste Hazardous Waste Handling Facility

    International Nuclear Information System (INIS)

    Albert, R.

    1992-01-01

    The purpose of this plan is to describe the organization and methodology for the certification of radioactive mixed waste (RMW) handled in the Hazardous Waste Handling Facility at Lawrence Berkeley Laboratory (LBL). RMW is low-level radioactive waste (LLW) or transuranic (TRU) waste that is co-contaminated with dangerous waste as defined in the Westinghouse Hanford Company (WHC) Solid Waste Acceptance Criteria (WAC) and the Washington State Dangerous Waste Regulations, 173-303-040 (18). This waste is to be transferred to the Hanford Site Central Waste Complex and Burial Grounds in Hanford, Washington. This plan incorporates the applicable elements of waste reduction, which include both up-front minimization and end-product treatment to reduce the volume and toxicity of the waste; segregation of the waste as it applies to certification; an executive summary of the Waste Management Quality Assurance Implementing Management Plan (QAIMP) for the HWHF (Section 4); and a list of the current and planned implementing procedures used in waste certification

  2. Evolution of the Darlington NGS fuel handling computer systems

    International Nuclear Information System (INIS)

    Leung, V.; Crouse, B.

    1996-01-01

    The ability to improve the capabilities and reliability of digital control systems in nuclear power stations to meet changing plant and personnel requirements is a formidable challenge. Many of these systems have high quality assurance standards that must be met to ensure adequate nuclear safety. Also many of these systems contain obsolete hardware along with software that is not easily transported to newer technology computer equipment. Combining modern technology upgrades into a system of obsolete hardware components is not an easy task. Lastly, as users become more accustomed to using modern technology computer systems in other areas of the station (e.g. information systems), their expectations of the capabilities of the plant systems increase. This paper will present three areas of the Darlington NGS fuel handling computer system that have been or are in the process of being upgraded to current technology components within the framework of an existing fuel handling control system. (author). 3 figs

  3. Evolution of the Darlington NGS fuel handling computer systems

    Energy Technology Data Exchange (ETDEWEB)

    Leung, V; Crouse, B [Ontario Hydro, Bowmanville (Canada). Darlington Nuclear Generating Station

    1997-12-31

    The ability to improve the capabilities and reliability of digital control systems in nuclear power stations to meet changing plant and personnel requirements is a formidable challenge. Many of these systems have high quality assurance standards that must be met to ensure adequate nuclear safety. Also many of these systems contain obsolete hardware along with software that is not easily transported to newer technology computer equipment. Combining modern technology upgrades into a system of obsolete hardware components is not an easy task. Lastly, as users become more accustomed to using modern technology computer systems in other areas of the station (e.g. information systems), their expectations of the capabilities of the plant systems increase. This paper will present three areas of the Darlington NGS fuel handling computer system that have been or are in the process of being upgraded to current technology components within the framework of an existing fuel handling control system. (author). 3 figs.

  4. Evaluating the service quality of undergraduate nursing education in Taiwan--using quality function deployment.

    Science.gov (United States)

    Chou, Shieu-Ming

    2004-05-01

    This study applies quality function deployment (QFD) techniques to evaluate the quality of service of undergraduate nursing education in Taiwan from the perspective of nursing students. Survey data from 560 undergraduate nursing students at four Taiwanese universities were subjected to QFD analysis in order to identify the quality characteristics most highly valued by students, the elements of educational service they consider most important and least important, and relationships/discrepancies between student quality requirements and institutional service elements. Results show that students value traditional elements of nursing education - clinical practice and lectures - more highly than recent additions such as computer-aided instruction and multimedia teaching. Results also show that students are looking for quality primarily in the area of faculty characteristics. The implication is that institutions which provide nursing education should not neglect the importance of investing in faculty when they are seeking to upgrade the quality of their programs. Further QFD studies are recommended to evaluate the quality of nursing education from the perspective of preceptors and nurses who help to train students in clinical settings.

  5. Hybrid Model for e-Learning Quality Evaluation

    Directory of Open Access Journals (Sweden)

    Suzana M. Savic

    2012-02-01

    Full Text Available E-learning is becoming increasingly important for the competitive advantage of economic organizations and higher education institutions. Therefore, it is becoming a significant aspect of quality which has to be integrated into the management system of every organization or institution. The paper examines e-learning quality characteristics, standards, criteria and indicators and presents a multi-criteria hybrid model for e-learning quality evaluation based on the method of Analytic Hierarchy Process, trend analysis, and data comparison.

  6. Cask system design guidance for robotic handling

    International Nuclear Information System (INIS)

    Griesmeyer, J.M.; Drotning, W.D.; Morimoto, A.K.; Bennett, P.C.

    1990-10-01

    Remote automated cask handling has the potential to reduce both the occupational exposure and the time required to process a nuclear waste transport cask at a handling facility. The ongoing Advanced Handling Technologies Project (AHTP) at Sandia National Laboratories is described. AHTP was initiated to explore the use of advanced robotic systems to perform cask handling operations at handling facilities for radioactive waste, and to provide guidance to cask designers regarding the impact of robotic handling on cask design. The proof-of-concept robotic systems developed in AHTP are intended to extrapolate from currently available commercial systems to the systems that will be available by the time that a repository would be open for operation. The project investigates those cask handling operations that would be performed at a nuclear waste repository facility during cask receiving and handling. The ongoing AHTP indicates that design guidance, rather than design specification, is appropriate, since the requirements for robotic handling do not place severe restrictions on cask design but rather focus on attention to detail and design for limited dexterity. The cask system design features that facilitate robotic handling operations are discussed, and results obtained from AHTP design and operation experience are summarized. The application of these design considerations is illustrated by discussion of the robot systems and their operation on cask feature mock-ups used in the AHTP project. 11 refs., 11 figs

  7. Power handling capability of Faraday rotation isolators for CO(2) laser radars.

    Science.gov (United States)

    Klein, C A; Dorschner, T A

    1989-03-01

    Faraday rotation isolators for CO(2) laser radars must be capable of handling substantial average power loads without degrading the beam quality or experiencing thermal runaway. For this reason, the semiconductorbased isolators, which are of promise for applications at 10.6 microm, must be cooled. This creates radial temperature gradients and, in conjunction with a nonuniform beam pattern, may lead to severe wavefront aberrations. It is the purpose of this paper to formulate simple procedures for assessing the impact of such aberrations in a cw regime and to provide a prescription on how to proceed in the context of designing or evaluating Faraday rotators for CO(2) laser systems. If it is a good approximation to describe the beam-induced temperature rise by means of a fourth-order even polynomial, the degradation in beam quality originates entirely from the quartic term deltaT(4)rho(4). Specifically, it is the spherical aberration factor S = deltaT(4) radicalvar[rho(4)] that best describes the combined impact of temperature profile and beam shape. The heat flow equation for cw-loaded, edge-cooled, or face-cooled cylindrical Faraday rotator elements can be formulated in a simple nondimensional manner, which demonstrates that (a) temperature variations causing optical distortion scale with betaP/K, i.e., linearly with the deposited power per unit path length and inversely with the thermal conductivity; (b) in a transmission mode of operation with edge cooling and no thermal runaway, the power handling capability is independent of the aperture diameter; and (c), in a double-pass reflection mode of operation that takes advantage of a face-cooled back surface, a significant reduction of the distortion requires Nusselt numbers of at least 10, which leads to a new figure of merit for characterizing the performance of Faraday rotator material candidates. Edge-cooled optical isolators described in the published literature then provide cases for exercising the formalism and

  8. Production management of window handles

    Directory of Open Access Journals (Sweden)

    Manuela Ingaldi

    2014-12-01

    Full Text Available In the chapter a company involved in the production of aluminum window and door handles was presented. The main customers of the company are primarily companies which produce PCV joinery and wholesalers supplying these companies. One chosen product from the research company - a single-arm pin-lift window handle - was described and its production process depicted technologically. The chapter also includes SWOT analysis conducted in the research company and the value stream of the single-arm pin-lift window handle.

  9. 7 CFR 58.443 - Whey handling.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Whey handling. 58.443 Section 58.443 Agriculture... Procedures § 58.443 Whey handling. (a) Adequate sanitary facilities shall be provided for the handling of whey. If outside, necessary precautions shall be taken to minimize flies, insects and development of...

  10. Airline service quality evaluation: A review on concepts and models

    OpenAIRE

    Navid Haghighat

    2017-01-01

    This paper reviews different major service quality concept and models which led to great developments in evaluating service quality with focusing on improvement process of the models through discussing criticisms of each model. Criticisms against these models are discussed to clarify development steps of newer models which led to the improvement of airline service quality models. The precise and accurate evaluation of service quality needs utilizing a reliable concept with comprehensive crite...

  11. Research on Air Quality Evaluation based on Principal Component Analysis

    Science.gov (United States)

    Wang, Xing; Wang, Zilin; Guo, Min; Chen, Wei; Zhang, Huan

    2018-01-01

    Economic growth has led to environmental capacity decline and the deterioration of air quality. Air quality evaluation as a fundamental of environmental monitoring and air pollution control has become increasingly important. Based on the principal component analysis (PCA), this paper evaluates the air quality of a large city in Beijing-Tianjin-Hebei Area in recent 10 years and identifies influencing factors, in order to provide reference to air quality management and air pollution control.

  12. Evaluating the Quality of the Child Care in Finland

    Science.gov (United States)

    Hujala, Eeva; Fonsen, Elina; Elo, Janniina

    2012-01-01

    In this study we examine parents' and teachers' perceptions of the early childhood education and care (ECEC) quality in Finland. The study is based on the paradigm of inclusionary quality and the assessment is based on the quality evaluation model. The parents and teachers assess the quality to be good. The strength of the quality was the effect…

  13. The use of physical model simulation to emulate an AGV material handling system

    International Nuclear Information System (INIS)

    Hurley, R.G.; Coffman, P.E.; Dixon, J.R.; Walacavage, J.G.

    1987-01-01

    This paper describes an application of physical modeling to the simulation of a prototype AGV (Automatic Guided Vehicle) material handling system. Physical modeling is the study of complex automated manufacturing and material handling systems through the use of small scale components controlled by mini and/or microcomputers. By modeling the mechanical operations of the proposed AGV material handling system, it was determined that control algorithms and AGV dispatch rules could be developed and evaluated. This paper presents a brief explanation of physical modeling as a simulation tool and addresses in detail the development of the control algorithm, dispatching rules, and a prototype physical model of a flexible machining system

  14. Construction of a Learning Agent Handling Its Rewards According to Environmental Situations

    Science.gov (United States)

    Moriyama, Koichi; Numao, Masayuki

    The authors aim at constructing an agent which learns appropriate actions in a Multi-Agent environment with and without social dilemmas. For this aim, the agent must have nonrationality that makes it give up its own profit when it should do that. Since there are many studies on rational learning that brings more and more profit, it is desirable to utilize them for constructing the agent. Therefore, we use a reward-handling manner that makes internal evaluation from the agent's rewards, and then the agent learns actions by a rational learning method with the internal evaluation. If the agent has only a fixed manner, however, it does not act well in the environment with and without dilemmas. Thus, the authors equip the agent with several reward-handling manners and criteria for selecting an effective one for the environmental situation. In the case of humans, what generates the internal evaluation is usually called emotion. Hence, this study also aims at throwing light on emotional activities of humans from a constructive view. In this paper, we divide a Multi-Agent environment into three situations and construct an agent having the reward-handling manners and the criteria. We observe that the agent acts well in all the three Multi-Agent situations composed of homogeneous agents.

  15. Criticality safety evaluation report for the cold vacuum drying facility's process water handling system

    International Nuclear Information System (INIS)

    NELSON, J.V.

    1999-01-01

    This report addresses the criticality concerns associated with process water handling in the Cold Vacuum Drying Facility. The controls and limitations on equipment design and operations to control potential criticality occurrences are identified

  16. Data envelopment analysis in service quality evaluation: an empirical study

    Science.gov (United States)

    Najafi, Seyedvahid; Saati, Saber; Tavana, Madjid

    2015-09-01

    Service quality is often conceptualized as the comparison between service expectations and the actual performance perceptions. It enhances customer satisfaction, decreases customer defection, and promotes customer loyalty. Substantial literature has examined the concept of service quality, its dimensions, and measurement methods. We introduce the perceived service quality index (PSQI) as a single measure for evaluating the multiple-item service quality construct based on the SERVQUAL model. A slack-based measure (SBM) of efficiency with constant inputs is used to calculate the PSQI. In addition, a non-linear programming model based on the SBM is proposed to delineate an improvement guideline and improve service quality. An empirical study is conducted to assess the applicability of the method proposed in this study. A large number of studies have used DEA as a benchmarking tool to measure service quality. These models do not propose a coherent performance evaluation construct and consequently fail to deliver improvement guidelines for improving service quality. The DEA models proposed in this study are designed to evaluate and improve service quality within a comprehensive framework and without any dependency on external data.

  17. Development of commercial robots for radwaste handling

    International Nuclear Information System (INIS)

    Colborn, K.A.

    1988-01-01

    The cost and dose burden associated with low level radwaste handling activities is a matter of increasing concern to the commercial nuclear power industry. This concern is evidenced by the fact that many utilities have begun to revaluate waste generation, handling, and disposal activities at their plants in an effort to improve their overall radwaste handling operations. This paper reports on the project Robots for Radwaste Handling, to identify the potential of robots to improve radwaste handling operations. The project has focussed on the potential of remote or automated technology to improve well defined, recognizable radwaste operations. The project focussed on repetitive, low skill level radwaste handling and decontamination tasks which involve significant radiation exposure

  18. Pre-slaughter sound levels and pre-slaughter handling from loading at the farm till slaughter influence pork quality.

    Science.gov (United States)

    Vermeulen, L; Van de Perre, V; Permentier, L; De Bie, S; Verbeke, G; Geers, R

    2016-06-01

    This study investigates the relationship between sound levels, pre-slaughter handling during loading and pork quality. Pre-slaughter variables were investigated from loading till slaughter. A total of 3213 pigs were measured 30 min post-mortem for pH(30LT) (M. Longissimus thoracis). First, a sound level model for the risk to develop PSE meat was established. The difference in maximum and mean sound level during loading, mean sound level during lairage and mean sound level prior to stunning remained significant within the model. This indicated that sound levels during loading had a significant added value to former sound models. Moreover, this study completed the global classification checklist (Vermeulen et al., 2015a) by developing a linear mixed model for pH(30LT) and PSE prevalence, with the difference in maximum and mean sound level measured during loading, the feed withdrawal period and the difference in temperature during loading and lairage. Hence, this study provided new insights over previous research where loading procedures were not included. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Influence of visual appearance on loudspeaker sound quality evaluation

    DEFF Research Database (Denmark)

    Karandreas, Theodoros-Alexandros; Christensen, Flemming

    2008-01-01

    Product sound quality evaluation aims to identify relevant attributes and assess their influence on the overall auditory impression. Extending this sound specific rationale, the present study evaluates overall impression in relation to audition and vision, specifically for loudspeakers. In order...... to quantify the bias that the loudspeaker appearance has on the sound quality evaluation of a naive listening panel, audio stimuli of varied degradation are coupled with actual loudspeakers of different visual appearance....

  20. Programme evaluation: Maintaining quality in higher education ...

    African Journals Online (AJOL)

    The evaluation of educational or social programmes is paramount for establishing success or impact in higher education. Evaluation questions about programme goals (e.g. better performance of first-year students) or about the quality of programme strategies (design and implementation) and effectiveness of delivery ...

  1. Clinical image quality evaluation for panoramic radiography in Korean dental clinics

    International Nuclear Information System (INIS)

    Choi, Bo Ram; Choi, Da Hye; Huh, Kyung Hoe; Yi, Won Jin; Heo, Min Suk; Choi, Soon Chul; Bae, Kwang Hak; Lee, Sam Sun

    2012-01-01

    The purpose of this study was to investigate the level of clinical image quality of panoramic radiographs and to analyze the parameters that influence the overall image quality. Korean dental clinics were asked to provide three randomly selected panoramic radiographs. An oral and maxillofacial radiology specialist evaluated those images using our self-developed Clinical Image Quality Evaluation Chart. Three evaluators classified the overall image quality of the panoramic radiographs and evaluated the causes of imaging errors. A total of 297 panoramic radiographs were collected from 99 dental hospitals and clinics. The mean of the scores according to the Clinical Image Quality Evaluation Chart was 79.9. In the classification of the overall image quality, 17 images were deemed 'optimal for obtaining diagnostic information,' 153 were 'adequate for diagnosis,' 109 were 'poor but diagnosable,' and nine were 'unrecognizable and too poor for diagnosis'. The results of the analysis of the causes of the errors in all the images are as follows: 139 errors in the positioning, 135 in the processing, 50 from the radiographic unit, and 13 due to anatomic abnormality. Panoramic radiographs taken at local dental clinics generally have a normal or higher-level image quality. Principal factors affecting image quality were positioning of the patient and image density, sharpness, and contrast. Therefore, when images are taken, the patient position should be adjusted with great care. Also, standardizing objective criteria of image density, sharpness, and contrast is required to evaluate image quality effectively.

  2. Recommendations for Collection and Handling of Specimens From Group Breast Cancer Clinical Trials

    Science.gov (United States)

    Leyland-Jones, Brian R.; Ambrosone, Christine B.; Bartlett, John; Ellis, Matthew J.C.; Enos, Rebecca A.; Raji, Adekunle; Pins, Michael R.; Zujewski, Jo Anne; Hewitt, Stephen M.; Forbes, John F.; Abramovitz, Mark; Braga, Sofia; Cardoso, Fatima; Harbeck, Nadia; Denkert, Carsten; Jewell, Scott D.

    2008-01-01

    Recommendations for specimen collection and handling have been developed for adoption across breast cancer clinical trials conducted by the Breast International Group (BIG)-sponsored Groups and the National Cancer Institute (NCI)-sponsored North American Cooperative Groups. These recommendations are meant to promote identifiable standards for specimen collection and handling within and across breast cancer trials, such that the variability in collection/handling practices that currently exists is minimized and specimen condition and quality are enhanced, thereby maximizing results from specimen-based diagnostic testing and research. Three working groups were formed from the Cooperative Group Banking Committee, BIG groups, and North American breast cancer cooperative groups to identify standards for collection and handling of (1) formalin-fixed, paraffin-embedded (FFPE) tissue; (2) blood and its components; and (3) fresh/frozen tissue from breast cancer trials. The working groups collected standard operating procedures from multiple group specimen banks, administered a survey on banking practices to those banks, and engaged in a series of discussions from 2005 to 2007. Their contributions were synthesized into this document, which focuses primarily on collection and handling of specimens to the point of shipment to the central bank, although also offers some guidance to central banks. Major recommendations include submission of an FFPE block, whole blood, and serial serum or plasma from breast cancer clinical trials, and use of one fixative and buffer type (10% neutral phosphate-buffered formalin, pH 7) for FFPE tissue across trials. Recommendations for proper handling and shipping were developed for blood, serum, plasma, FFPE, and fresh/frozen tissue. PMID:18955459

  3. Preference Handling for Artificial Intelligence

    OpenAIRE

    Goldsmith, Judy; University of Kentucky; Junker, Ulrich; ILOG

    2009-01-01

    This article explains the benefits of preferences for AI systems and draws a picture of current AI research on preference handling. It thus provides an introduction to the topics covered by this special issue on preference handling.

  4. Religious Serpent Handling and Community Relations.

    Science.gov (United States)

    Williamson, W Paul; Hood, Ralph W

    2015-01-01

    Christian serpent handling sects of Appalachia comprise a community that has long been mischaracterized and marginalized by the larger communities surrounding them. To explore this dynamic, this article traces the emergence of serpent handling in Appalachia and the emergence of anti-serpent-handling state laws, which eventually failed to curb the practice, as local communities gave serpent handling groups support. We present two studies to consider for improving community relations with serpent handling sects. In study 1, we present data relating the incidence of reported serpent-bite deaths with the rise of anti-serpent-handling laws and their eventual abatement, based on increasing acceptance of serpent handlers by the larger community. Study 2 presents interview data on serpent bites and death that provide explanations for these events from the cultural and religious perspective. We conclude that first-hand knowledge about serpent handlers, and other marginalized groups, helps to lessen suspicion and allows them to be seen as not much different, which are tendencies that are important for promoting inter-community harmony.

  5. Design of systems for handling radioactive ion exchange resin beads

    International Nuclear Information System (INIS)

    Shapiro, S.A.; Story, G.L.

    1979-01-01

    The flow of slurries in pipes is a complex phenomenon. There are little slurry data available on which to base the design of systems for radioactive ion exchange resin beads and, as a result, the designs vary markedly in operating plants. With several plants on-line, the opportunity now exists to evaluate the designs of systems handling high activity spent resin beads. Results of testing at Robbins and Meyers Pump Division to quantify the behavior of resin bead slurries are presented. These tests evaluated the following slurry parameters; resin slurry velocity, pressure drop, bead degradation, and slurry concentration effects. A discussion of the general characteristics of resin bead slurries is presented along with a correlation to enable the designer to establish the proper flowrate for a given slurry composition and flow regime as a function of line size. Guidelines to follow in designing a resin handling system are presented

  6. Musculoskeletal injuries resulting from patient handling tasks among hospital workers.

    Science.gov (United States)

    Pompeii, Lisa A; Lipscomb, Hester J; Schoenfisch, Ashley L; Dement, John M

    2009-07-01

    The purpose of this study was to evaluate musculoskeletal injuries and disorders resulting from patient handling prior to the implementation of a "minimal manual lift" policy at a large tertiary care medical center. We sought to define the circumstances surrounding patient handling injuries and to identify potential preventive measures. Human resources data were used to define the cohort and their time at work. Workers' compensation records (1997-2003) were utilized to identify work-related musculoskeletal claims, while the workers' description of injury was used to identify those that resulted from patient handling. Adjusted rate ratios were generated using Poisson regression. One-third (n = 876) of all musculoskeletal injuries resulted from patient handling activities. Most (83%) of the injury burden was incurred by inpatient nurses, nurses' aides and radiology technicians, while injury rates were highest for nurses' aides (8.8/100 full-time equivalent, FTEs) and smaller workgroups including emergency medical technicians (10.3/100 FTEs), patient transporters (4.3/100 FTEs), operating room technicians (3.1/100 FTEs), and morgue technicians (2.2/100 FTEs). Forty percent of injuries due to lifting/transferring patients may have been prevented through the use of mechanical lift equipment, while 32% of injuries resulting from repositioning/turning patients, pulling patients up in bed, or catching falling patients may not have been prevented by the use of lift equipment. The use of mechanical lift equipment could significantly reduce the risk of some patient handling injuries but additional interventions need to be considered that address other patient handling tasks. Smaller high-risk workgroups should not be neglected in prevention efforts.

  7. Decision method for optimal selection of warehouse material handling strategies by production companies

    Science.gov (United States)

    Dobos, P.; Tamás, P.; Illés, B.

    2016-11-01

    Adequate establishment and operation of warehouse logistics determines the companies’ competitiveness significantly because it effects greatly the quality and the selling price of the goods that the production companies produce. In order to implement and manage an adequate warehouse system, adequate warehouse position, stock management model, warehouse technology, motivated work force committed to process improvement and material handling strategy are necessary. In practical life, companies have paid small attantion to select the warehouse strategy properly. Although it has a major influence on the production in the case of material warehouse and on smooth costumer service in the case of finished goods warehouse because this can happen with a huge loss in material handling. Due to the dynamically changing production structure, frequent reorganization of warehouse activities is needed, on what the majority of the companies react basically with no reactions. This work presents a simulation test system frames for eligible warehouse material handling strategy selection and also the decision method for selection.

  8. Safe handling of tritium

    International Nuclear Information System (INIS)

    1991-01-01

    The main objective of this publication is to provide practical guidance and recommendations on operational radiation protection aspects related to the safe handling of tritium in laboratories, industrial-scale nuclear facilities such as heavy-water reactors, tritium removal plants and fission fuel reprocessing plants, and facilities for manufacturing commercial tritium-containing devices and radiochemicals. The requirements of nuclear fusion reactors are not addressed specifically, since there is as yet no tritium handling experience with them. However, much of the material covered is expected to be relevant to them as well. Annex III briefly addresses problems in the comparatively small-scale use of tritium at universities, medical research centres and similar establishments. However, the main subject of this publication is the handling of larger quantities of tritium. Operational aspects include designing for tritium safety, safe handling practice, the selection of tritium-compatible materials and equipment, exposure assessment, monitoring, contamination control and the design and use of personal protective equipment. This publication does not address the technologies involved in tritium control and cleanup of effluents, tritium removal, or immobilization and disposal of tritium wastes, nor does it address the environmental behaviour of tritium. Refs, figs and tabs

  9. Programme Evaluation: Maintaining Quality in Higher Education

    Science.gov (United States)

    Loots, A.

    2008-01-01

    The evaluation of educational or social programmes is paramount for establishing success or impact in higher education. Evaluation questions about programme goals (e.g. better performance of first-year students) or about the quality of programme strategies (design and implementation) and effectiveness of delivery (coordinator inputs and…

  10. How Retailers Handle Complaint Management

    DEFF Research Database (Denmark)

    Hansen, Torben; Wilke, Ricky; Zaichkowsky, Judy

    2009-01-01

    This article fills a gap in the literature by providing insight about the handling of complaint management (CM) across a large cross section of retailers in the grocery, furniture, electronic and auto sectors. Determinants of retailers’ CM handling are investigated and insight is gained as to the......This article fills a gap in the literature by providing insight about the handling of complaint management (CM) across a large cross section of retailers in the grocery, furniture, electronic and auto sectors. Determinants of retailers’ CM handling are investigated and insight is gained...... as to the links between CM and redress of consumers’ complaints. The results suggest that retailers who attach large negative consequences to consumer dissatisfaction are more likely than other retailers to develop a positive strategic view on customer complaining, but at the same time an increase in perceived...

  11. [HERA-QUEST: HTA evaluation of generic pharmaceutical products to improve quality, economic efficiency, patient safety and transparency in drug product changes in hospitals].

    Science.gov (United States)

    Gyalrong-Steur, Miriam; Kellermann, Anita; Bernard, Rudolf; Berndt, Georg; Bindemann, Meike; Nusser-Rothermundt, Elfriede; Amann, Steffen; Brakebusch, Myga; Brüggmann, Jörg; Tydecks, Eva; Müller, Markus; Dörje, Frank; Kochs, Eberhard; Riedel, Rainer

    2017-04-01

    In view of the rising cost pressure and an increasing number of drug shortages, switches between generic drug preparations have become a daily routine in hospitals. To ensure consistently high treatment quality and best possible patient safety, the equivalence of the new and the previous drug preparation must be ensured before any change in the purchase of pharmaceutical products takes place. So far, no easily usable, transparent and standardized instrument for this kind of comparison between generic drug products has been available. A group of pharmaceutical experts has developed the drug HTA (health technology assessment) model "HERA" (HTA Evaluation of geneRic phArmaceutical products) through a multi-step process. The instrument is designed to perform both a qualitative and economic comparison of equivalent drug preparations ("aut idem" substitution) before switching products. The economic evaluation does not only consider unit prices and consumption quantity, but also the processing costs associated with a product change process. The qualitative comparison is based on the evaluation of 34 quality criteria belonging to six evaluation fields (e.g., approval status, practical handling, packaging design). The objective evaluation of the quality criteria is complemented by an assessment of special features of the individual hospital for complex drug switches, including the feedback of the physicians utilizing the drug preparation. Thus potentially problematic switches of pharmaceutical products can be avoided at the best possible rate, contributing to the improvement of patient safety. The novel drug HTA model HERA is a tool used in clinical practice that can add to an increase in quality, therapeutic safety and transparency of drug use while simultaneously contributing to the economic optimization of drug procurement in hospitals. Combining these two is essential for hospitals facing the tension between rising cost pressure and at the same time increasing demands

  12. Reproductive handle of the herd of cattle of double purpose

    International Nuclear Information System (INIS)

    Castro Hernandez, A.

    1988-01-01

    The influence of the environmental factors is analyzed, in the reproductive efficiency of herd cattle of double purpose. The reproductive behavior begins with the gestation of the heifers. Under the conditions of the Colombian tropic these they reach the weight required for the reproduction to an age but late that in the temperate areas. Once the first childbirth, the cow takes place it enters in exhaustion that makes that this animal is the but difficult to reproduce after the childbirth, that which demands special cares of handling and feeding. The interval among the childbirth to evaluate the reproductive efficiency. Environmental factors that influence significantly. The use of the practice simple of handling, health, selection and feeding produces significant increments in the fertility of the herd of cattle of double purpose. One practices of effective handling in the improvement of the reproductive behavior of the cows of double purpose it is the restricted nursing

  13. 7 CFR 926.9 - Handle.

    Science.gov (United States)

    2010-01-01

    ... the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements and Orders; Fruits, Vegetables, Nuts), DEPARTMENT OF AGRICULTURE DATA COLLECTION, REPORTING AND RECORDKEEPING REQUIREMENTS APPLICABLE TO CRANBERRIES NOT SUBJECT TO THE CRANBERRY MARKETING ORDER § 926.9 Handle. Handle...

  14. Evolution of a test article handling system for the SP-100 ground engineering system test

    International Nuclear Information System (INIS)

    Shen, E.J.; Schweiger, L.J.; Miller, W.C.; Gluck, R.; Devies, S.M.

    1987-04-01

    A simulated space environment test of a flight prototypic SP-100 reactor, control system, and flight shield will be conducted at the Hanford Engineering Development Laboratory (HEDL). The flight prototypic components and the supporting primary heat removal system are collectively known as the Nuclear Assembly Test Article (TA). The unique configuration and materials of fabrication for the Test Article require a specialized handling facility to support installation, maintenance, and final disposal operations. Westinghouse Hanford Company, the Test Site Operator, working in conjunction with General Electric Company, the Test Article supplier, developed and evaluated several handling concepts resulting in the selection of a reference Test Article Handling System. The development of the reference concept for the handling system is presented

  15. New approach to equipment quality evaluation method with distinct functions

    Directory of Open Access Journals (Sweden)

    Milisavljević Vladimir M.

    2016-01-01

    Full Text Available The paper presents new approach for improving method for quality evaluation and selection of equipment (devices and machinery by applying distinct functions. Quality evaluation and selection of devices and machinery is a multi-criteria problem which involves the consideration of numerous parameters of various origins. Original selection method with distinct functions is based on technical parameters with arbitrary evaluation of each parameter importance (weighting. Improvement of this method, presented in this paper, addresses the issue of weighting of parameters by using Delphi Method. Finally, two case studies are provided, which included quality evaluation of standard boilers for heating and evaluation of load-haul-dump (LHD machines, to demonstrate applicability of this approach. Analytical Hierarchical Process (AHP is used as a control method.

  16. Routine post-weaning handling of rats prevents isolation rearing-induced deficit in prepulse inhibition

    Directory of Open Access Journals (Sweden)

    M.L.N.M. Rosa

    2005-11-01

    Full Text Available Rats reared under isolation conditions from weaning present a number of behavioral changes compared to animals reared under social conditions (group housing. These changes include deficits in prepulse inhibition (PPI of the startle reflex to a loud sound. PPI refers to the reduction of the magnitude of the startle reflex when a relatively weak stimulus (the prepulse precedes by an appropriate time interval the intense startle-elicing stimulus (the pulse. PPI is useful for studying sensorimotor integration. The present study evaluated the effect of handling on the impairment of PPI induced by isolation-rearing. Male Wistar rats (N = 11-15/group were housed in groups (5 per cage and handled three times a week or isolated (housed individually since weaning (21 days for 10 weeks when they reach approximately 150 g. The isolated rats were divided into "minimally handled" animals (handled once a week for cleaning purposes only or "handled" animals (handled three times a week. This handling consisted of grasping the rat by the tail and moving it to a clean cage (approximately 5 s. A statistically significant reduction (52% in the PPI test was found only in the isolated group with minimal handling while no difference was seen between grouped animals and isolated handled animals. These results indicate that isolation rearing causes disruption in the PPI at adult age, which serves as an index of attention deficit. This change in the sensory processing of information induced by post-weaning isolation can be prevented by handling during the development of the animal.

  17. Routine post-weaning handling of rats prevents isolation rearing-induced deficit in prepulse inhibition.

    Science.gov (United States)

    Rosa, M L N M; Silva, R C B; Moura-de-Carvalho, F T; Brandão, M L; Guimarães, F S; Del Bel, E A

    2005-11-01

    Rats reared under isolation conditions from weaning present a number of behavioral changes compared to animals reared under social conditions (group housing). These changes include deficits in prepulse inhibition (PPI) of the startle reflex to a loud sound. PPI refers to the reduction of the magnitude of the startle reflex when a relatively weak stimulus (the prepulse) precedes by an appropriate time interval the intense startle-elicing stimulus (the pulse). PPI is useful for studying sensorimotor integration. The present study evaluated the effect of handling on the impairment of PPI induced by isolation-rearing. Male Wistar rats (N = 11-15/group) were housed in groups (5 per cage and handled three times a week) or isolated (housed individually) since weaning (21 days) for 10 weeks when they reach approximately 150 g. The isolated rats were divided into "minimally handled" animals (handled once a week for cleaning purposes only) or "handled" animals (handled three times a week). This handling consisted of grasping the rat by the tail and moving it to a clean cage (approximately 5 s). A statistically significant reduction (52%) in the PPI test was found only in the isolated group with minimal handling while no difference was seen between grouped animals and isolated handled animals. These results indicate that isolation rearing causes disruption in the PPI at adult age, which serves as an index of attention deficit. This change in the sensory processing of information induced by post-weaning isolation can be prevented by handling during the development of the animal.

  18. [Care quality in intensive care evaluated by the patients using a service quality scale (SERVQUAL)].

    Science.gov (United States)

    Regaira Martínez, E; Sola Iriarte, M; Goñi Viguria, R; Del Barrio Linares, M; Margall Coscojuela, M A; Asiain Erro, M C

    2010-01-01

    The evaluation made by the patients on the quality of service received is important to introduce improvement strategies in the care quality. 1. To evaluate the care quality through the analysis of the differences obtained between expectations and perceptions, that the patients have of the service received in the ICU. 2. To analyze if there is any relationship between care quality evaluated by the patients and the sociodemographic variables. A total of 86 patients who were conscious and oriented during their stay in the ICU were studied prospectively. At 24h of the discharge from the ICU, the SERVQUAL (Service Quality) scale, adapted for the hospital setting by Babakus and Mangold (1992), was applied. This scale measures the care quality based on the difference in scores obtained between expectations and perceptions of the patients. The positive scores indicate that the perceptions of the patients exceed their expectations. The scale has 5 dimensions: Tangibility, Reliability, Responsiveness, Assurances and Empathy. It includes 15 items for perceptions and the same for expectations, with 5 grades of response (1 totally disagree - 5 totally agree). The mean score of perceptions 66.92) exceeded that of the expectations (62.30). The mean score of the difference between perceptions and expectations for the total of the SERVQUAL scale was 4.62. It was also positive for each one of the dimensions: Tangibility=1.44, Reliability=0.53, Responsiveness=0.95, Assurances=0.99, Empathy=0.71. No statistically significant associations were found between care quality evaluated by the patients and the sociodemographic variables. The care quality perceived by the patients in the ICU exceeds their expectations, and had no relationship with the sociodemographic characteristics. Copyright 2009 Elsevier España, S.L. y SEEIUC. All rights reserved.

  19. Exploring in integrated quality evaluation of Chinese herbal medicines: the integrated quality index (IQI) for aconite.

    Science.gov (United States)

    Zhang, Ding-kun; Wang, Jia-bo; Yang, Ming; Peng, Cheng; Xiao, Xiao-he

    2015-07-01

    Good medicinal herbs, good drugs. Good evaluation method and indices are the prerequisite of good medicinal herbs. However, there exist numerous indices for quality evaluation and control in Chinese medicinal materials. However, most of these indices are non-interrelated each other, as well as having little relationship with efficiency and safety. The results of different evaluatior methods may not be consistent, even contradictory. Considering the complex material properties of Chinese medicinal materials, single method and index is difficult to objectively and comprehensively reflect the quality. Therefore, it is essential to explore the integrated evaluation methods. In this paper, oriented by the integrated evaluation strategies for traditional Chinese medicine quality, a new method called integrated quality index (IQI) by the integration of empirical evaluation, chemical evaluation, and biological evaluation was proposed. In addition, a study case of hypertoxic herb Aconitum carmichaelii Debx. was provided to explain this method in detail. The results suggested that in the view of specifications, the average weight of Jiangyou aconite was the greatest, followed by Weishan aconite, Butuo aconite, Hanzhong aconite, and Anxian aconite; from the point of chemical components, Jiangyou aconite had the characteristic with strong efficacy and weak toxicity, next was Hanzhong aconite, Butuo aconite, Weishan aconite, and Anxian aconite; taking toxicity price as the index, Hanzhong aconite and Jiangyou aconite have the lower toxicity, while Butuo aconite, Weishan aconite, and Anxian aconite have the relatively higher one. After the normalization and integration of evaluation results, we calculated the IQI value of Jiangyou aconite, Hanzhong aconite, Butuo aconite, Weishan aconite, and Anxian aconite were 0.842 +/- 0.091, 0.597 +/- 0.047, 0.442 +/- 0.033, 0.454 +/- 0.038, 0.170 +/- 0.021, respectively. The quality of Jiangyou aconite is significantly better than the

  20. Remote handling at LAMPF

    International Nuclear Information System (INIS)

    Grisham, D.L.; Lambert, J.E.

    1983-01-01

    Experimental area A at the Clinton P. Anderson Meson Physics Facility (LAMPF) encompasses a large area. Presently there are four experimental target cells along the main proton beam line that have become highly radioactive, thus dictating that all maintenance be performed remotely. The Monitor remote handling system was developed to perform in situ maintenance at any location within area A. Due to the complexity of experimental systems and confined space, conventional remote handling methods based upon hot cell and/or hot bay concepts are not workable. Contrary to conventional remote handling which require special tooling for each specifically planned operation, the Monitor concept is aimed at providing a totally flexible system capable of remotely performing general mechanical and electrical maintenance operations using standard tools. The Monitor system is described

  1. Clinical image quality evaluation for panoramic radiography in Korean dental clinics

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Bo Ram; Choi, Da Hye; Huh, Kyung Hoe; Yi, Won Jin; Heo, Min Suk; Choi, Soon Chul; Bae, Kwang Hak; Lee, Sam Sun [School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2012-09-15

    The purpose of this study was to investigate the level of clinical image quality of panoramic radiographs and to analyze the parameters that influence the overall image quality. Korean dental clinics were asked to provide three randomly selected panoramic radiographs. An oral and maxillofacial radiology specialist evaluated those images using our self-developed Clinical Image Quality Evaluation Chart. Three evaluators classified the overall image quality of the panoramic radiographs and evaluated the causes of imaging errors. A total of 297 panoramic radiographs were collected from 99 dental hospitals and clinics. The mean of the scores according to the Clinical Image Quality Evaluation Chart was 79.9. In the classification of the overall image quality, 17 images were deemed 'optimal for obtaining diagnostic information,' 153 were 'adequate for diagnosis,' 109 were 'poor but diagnosable,' and nine were 'unrecognizable and too poor for diagnosis'. The results of the analysis of the causes of the errors in all the images are as follows: 139 errors in the positioning, 135 in the processing, 50 from the radiographic unit, and 13 due to anatomic abnormality. Panoramic radiographs taken at local dental clinics generally have a normal or higher-level image quality. Principal factors affecting image quality were positioning of the patient and image density, sharpness, and contrast. Therefore, when images are taken, the patient position should be adjusted with great care. Also, standardizing objective criteria of image density, sharpness, and contrast is required to evaluate image quality effectively.

  2. Subjective evaluation of compressed image quality

    Science.gov (United States)

    Lee, Heesub; Rowberg, Alan H.; Frank, Mark S.; Choi, Hyung-Sik; Kim, Yongmin

    1992-05-01

    Lossy data compression generates distortion or error on the reconstructed image and the distortion becomes visible as the compression ratio increases. Even at the same compression ratio, the distortion appears differently depending on the compression method used. Because of the nonlinearity of the human visual system and lossy data compression methods, we have evaluated subjectively the quality of medical images compressed with two different methods, an intraframe and interframe coding algorithms. The evaluated raw data were analyzed statistically to measure interrater reliability and reliability of an individual reader. Also, the analysis of variance was used to identify which compression method is better statistically, and from what compression ratio the quality of a compressed image is evaluated as poorer than that of the original. Nine x-ray CT head images from three patients were used as test cases. Six radiologists participated in reading the 99 images (some were duplicates) compressed at four different compression ratios, original, 5:1, 10:1, and 15:1. The six readers agree more than by chance alone and their agreement was statistically significant, but there were large variations among readers as well as within a reader. The displacement estimated interframe coding algorithm is significantly better in quality than that of the 2-D block DCT at significance level 0.05. Also, 10:1 compressed images with the interframe coding algorithm do not show any significant differences from the original at level 0.05.

  3. Project Execution Plan for the Remote Handled Low-Level Waste Disposal Project

    Energy Technology Data Exchange (ETDEWEB)

    Danny Anderson

    2014-07-01

    As part of ongoing cleanup activities at the Idaho National Laboratory (INL), closure of the Radioactive Waste Management Complex (RWMC) is proceeding under the Comprehensive Environmental Response, Compensation, and Liability Act (42 USC 9601 et seq. 1980). INL-generated radioactive waste has been disposed of at RWMC since 1952. The Subsurface Disposal Area (SDA) at RWMC accepted the bulk of INL’s contact and remote-handled low-level waste (LLW) for disposal. Disposal of contact-handled LLW and remote-handled LLW ion-exchange resins from the Advanced Test Reactor in the open pit of the SDA ceased September 30, 2008. Disposal of remote-handled LLW in concrete disposal vaults at RWMC will continue until the facility is full or until it must be closed in preparation for final remediation of the SDA (approximately at the end of fiscal year FY 2017). The continuing nuclear mission of INL, associated ongoing and planned operations, and Naval spent fuel activities at the Naval Reactors Facility (NRF) require continued capability to appropriately dispose of contact and remote handled LLW. A programmatic analysis of disposal alternatives for contact and remote-handled LLW generated at INL was conducted by the INL contractor in Fiscal Year 2006; subsequent evaluations were completed in Fiscal Year 2007. The result of these analyses was a recommendation to the Department of Energy (DOE) that all contact-handled LLW generated after September 30, 2008, be disposed offsite, and that DOE proceed with a capital project to establish replacement remote-handled LLW disposal capability. An analysis of the alternatives for providing replacement remote-handled LLW disposal capability has been performed to support Critical Decision-1. The highest ranked alternative to provide this required capability has been determined to be the development of a new onsite remote-handled LLW disposal facility to replace the existing remote-handled LLW disposal vaults at the SDA. Several offsite DOE

  4. Evaluating predictive models of software quality

    International Nuclear Information System (INIS)

    Ciaschini, V; Canaparo, M; Ronchieri, E; Salomoni, D

    2014-01-01

    Applications from High Energy Physics scientific community are constantly growing and implemented by a large number of developers. This implies a strong churn on the code and an associated risk of faults, which is unavoidable as long as the software undergoes active evolution. However, the necessities of production systems run counter to this. Stability and predictability are of paramount importance; in addition, a short turn-around time for the defect discovery-correction-deployment cycle is required. A way to reconcile these opposite foci is to use a software quality model to obtain an approximation of the risk before releasing a program to only deliver software with a risk lower than an agreed threshold. In this article we evaluated two quality predictive models to identify the operational risk and the quality of some software products. We applied these models to the development history of several EMI packages with intent to discover the risk factor of each product and compare it with its real history. We attempted to determine if the models reasonably maps reality for the applications under evaluation, and finally we concluded suggesting directions for further studies.

  5. Evaluating Predictive Models of Software Quality

    Science.gov (United States)

    Ciaschini, V.; Canaparo, M.; Ronchieri, E.; Salomoni, D.

    2014-06-01

    Applications from High Energy Physics scientific community are constantly growing and implemented by a large number of developers. This implies a strong churn on the code and an associated risk of faults, which is unavoidable as long as the software undergoes active evolution. However, the necessities of production systems run counter to this. Stability and predictability are of paramount importance; in addition, a short turn-around time for the defect discovery-correction-deployment cycle is required. A way to reconcile these opposite foci is to use a software quality model to obtain an approximation of the risk before releasing a program to only deliver software with a risk lower than an agreed threshold. In this article we evaluated two quality predictive models to identify the operational risk and the quality of some software products. We applied these models to the development history of several EMI packages with intent to discover the risk factor of each product and compare it with its real history. We attempted to determine if the models reasonably maps reality for the applications under evaluation, and finally we concluded suggesting directions for further studies.

  6. Feasibility study of CANDU-9 fuel handling system

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jeong Ki; Jo, C. H.; Kim, H. M.

    1996-12-01

    CANDU`s combination of natural uranium, heavy water and on-power refuelling is unique in its design and remarkable for reliable power production. In order to offer more output, better site utilization, shorter construction time, improved station layout, safety enhancements and better control panel layout, CANDU-9 is now under development with design improvement added to all proven CANDU advantages or applicable technologies. One of its major improvement has been applied to fuel handling system. This system is very similar to that of CANDU-3, and some parts of the system are applied to those of the existing CANDU-6 or CANDU-9. Design concepts and design requirements of fuel handling system for CANDU-9 have been identified to compare with those of the existing CANDU and the design feasibilities have been evaluated. (author). 4 tabs., 13 figs., 9 refs.

  7. [A workplace intervention aimed at increasing awareness in nursing personnel performing manual handling activities].

    Science.gov (United States)

    Scorpiniti, A; Lorusso, A; L'Abbate, N

    2007-01-01

    Here we describe a workplace intervention aimed at reducing the risk of low back pain in nursing personnel. The intervention we carried out included a specific ergonomic training and an exercise program according to the Feldenkrais Method. After the intervention, we evaluated its effect on the execution of manual handling activities in nurses. We found an increased rate of correct manual handling in the post-intervention period.

  8. Capsicum--production, technology, chemistry, and quality. Part IV. Evaluation of quality.

    Science.gov (United States)

    Govindarajan, V S; Rajalakshmi, D; Chand, N

    1987-01-01

    Capsicum fruits are popular worldwide and are used in the cuisines of both the developing and the developed countries. With its different varieties, forms, and uses, the spice capsicum contributes to the entire gamut of sensory experience--color as finely ground paprika powder or extract in sausages, goulash, cheese, and snacks; both pungency and color as the many varieties of chillies used in Mexican, African, Indian, and southeast Asian cuisines; color, aroma, and mild pungency as the fresh green chillies used in many of the growing countries; and appearance, color, aroma, and texture as fresh fruit in salads and as a pickled and canned product. In three earlier parts in this series, the varieties, cultivation, and primary processing; the processed products, world production, and trade; and the chemistry of the color, aroma, and pungency stimuli have been reviewed. In this part, the evaluation of quality through instrumental determination of the causal components and the sensory evaluation of color, aroma, and pungency are discussed. Several methods for quantitative determination of the stimuli and the sensory evaluation of the responses to the stimuli are reviewed. The problems of sensory evaluation of color, aroma, and pungency, the dominant attributes for validation of the instrumentally determined values for carotenoids, volatiles, or particular fractions, and total and individual capsaicinoids are specifically discussed. Summarized details of selected instrumental methods for evaluating the stimuli, which are either validated by correlation to sensorily perceived responses or to adopted standards, are given along with representative data obtained for discussing the adequacy and reliability of the methods. Pungency as a specific gustatory perception and the many methods proposed to evaluate this quality are discussed. A recommended objective procedure for obtaining reproducible values is discussed, and a method for relating different panel results is shown

  9. Implementation of an ergonomics intervention in a Swedish flight baggage handling company-A process evaluation.

    Science.gov (United States)

    Bergsten, Eva L; Mathiassen, Svend Erik; Larsson, Johan; Kwak, Lydia

    2018-01-01

    To conduct a process evaluation of the implementation of an ergonomics training program aimed at increasing the use of loading assist devices in flight baggage handling. Feasibility related to the process items recruitment, reach, context, dose delivered (training time and content); dose received (participants' engagement); satisfaction with training; intermediate outcomes (skills, confidence and behaviors); and barriers and facilitators of the training intervention were assessed by qualitative and quantitative methods. Implementation proved successful regarding dose delivered, dose received and satisfaction. Confidence among participants in the training program in using and talking about devices, observed use of devices among colleagues, and internal feedback on work behavior increased significantly (pjob insecurity. In identifying important barriers and facilitators for a successful outcome, this study can help supporting the effectiveness of future interventions. Our results suggest that barriers caused by organizational changes may likely be alleviated by recruiting motivated trainees and securing strong organizational support for the implementation.

  10. MRI of meniscal bucket-handle tears

    Energy Technology Data Exchange (ETDEWEB)

    Magee, T.H.; Hinson, G.W. [Menorah Medical Center, Overland Park, KS (United States). Dept. of Radiology

    1998-09-01

    A meniscal bucket-handle tear is a tear with an attached fragment displaced from the meniscus of the knee joint. Low sensitivity of MRI for detection of bucket-handle tears (64% as compared with arthroscopy) has been reported previously. We report increased sensitivity for detecting bucket-handle tears with the use of coronal short tau inversion recovery (STIR) images. Results. By using four criteria for diagnosis of meniscal bucket-handle tears, our overall sensitivity compared with arthroscopy was 93% (28 of 30 meniscal bucket-handle tears seen at arthroscopy were detected by MRI). The meniscal fragment was well visualized in all 28 cases on coronal STIR images. The double posterior cruciate ligament sign was seen in 8 of 30 cases, the flipped meniscus was seen in 10 of 30 cases and a fragment in the intercondylar notch was seen in 18 of 30 cases. (orig.)

  11. Development of remote handling techniques for the HLLW solidification plant

    International Nuclear Information System (INIS)

    Tosha, Yoshitsugu; Iwata, Toshio; Inada, Eiichi; Nagaki, Hiroshi; Yamamoto, Masao

    1982-01-01

    To develop the techniques for the remote maintenance of the equipment in a HLLW (high-level liquid waste) solidification plant, the mock-up test facility (MTF) has been designed and constructed. Before its construction, the specific mock-up equipment was manufactured and tested. The results of the test and the outline of the MTF are described. As the mock-up equipment, a denitrater-concentrator, a ceramic melter and a canister handling equipment were selected. Remote operation was performed according to the maintenance program, and the evaluation of the component was conducted on the easiness of operation, performance, and the suitability to remote handling equipment. As a result of the test, four important elements were identified; they were guides, lifting fixtures, remote handling bolts, and remote pipe connectors. Many improvements of these elements were achieved, and reflected in the design of the MTF. The MTF is a steel-framed and slate-covered building (25 mL x 20 mW x 27 mH) with five storys of test bases. It contains the following four main systems: pretreatment and off-gas treatment system, glass melting system, canister handling system and secondary waste liquid recovery system. Further development of the remote maintenance techniques is expected through the test in the MTF. (Aoki, K.)

  12. WASTE HANDLING BUILDING SHIELD WALL ANALYSIS

    International Nuclear Information System (INIS)

    Padula, D.

    2000-01-01

    The scope of this analysis is to estimate the shielding wall, ceiling or equivalent door thicknesses that will be required in the Waste Handling Building to maintain the radiation doses to personnel within acceptable limits. The shielding thickness calculated is the minimum required to meet administrative limits, and not necessarily what will be recommended for the final design. The preliminary evaluations will identify the areas which have the greatest impact on mechanical and facility design concepts. The objective is to provide the design teams with the necessary information to assure an efficient and effective design

  13. Pituitary-adrenocortical adjustments to transport stress in horses with previous different handling and transport conditions

    Directory of Open Access Journals (Sweden)

    E. Fazio

    2016-08-01

    Full Text Available Aim: The changes of the hypothalamic pituitary adrenal (HPA axis response to a long distance transportation results in increase of adrenocorticotropic hormone (ACTH and cortisol levels. The purpose of the study was to quantify the level of short-term road transport stress on circulating ACTH and cortisol concentrations, related to the effect of previous handling and transport experience of horses. Materials and Methods: The study was performed on 56 healthy horses after short-term road transport of 30 km. The horses were divided into four groups, Groups A, B, C, and D, with respect to the handling quality: Good (Groups A and B, bad (Group D, and minimal handling (Group C conditions. According to the previous transport, experience horses were divided as follows: Horses of Groups A and D had been experienced long-distance transportation before; horses of Groups B and C had been limited experience of transportation. Results: One-way RM-ANOVA showed significant effects of transport on ACTH changes in Groups B and C and on cortisol changes in both Groups A and B. Groups A and B showed lower baseline ACTH and cortisol values than Groups C and D; Groups A and B showed lower post-transport ACTH values than Groups C and D. Groups A, B, and C showed lower post-transport cortisol values than Group D. Only Groups A and B horses have shown an adequate capacity of stress response to transportation. Conclusion: The previous transport experience and quality of handling could influence the HPA axis physiological responses of horses after short-term road transport.

  14. Sophisticated fuel handling system evolved

    International Nuclear Information System (INIS)

    Ross, D.A.

    1988-01-01

    The control systems at Sellafield fuel handling plant are described. The requirements called for built-in diagnostic features as well as the ability to handle a large sequencing application. Speed was also important; responses better than 50ms were required. The control systems are used to automate operations within each of the three main process caves - two Magnox fuel decanners and an advanced gas-cooled reactor fuel dismantler. The fuel route within the fuel handling plant is illustrated and described. ASPIC (Automated Sequence Package for Industrial Control) which was developed as a controller for the plant processes is described. (U.K.)

  15. [Scientific evaluation--the basis for quality assurance in continuing medical education].

    Science.gov (United States)

    Haffner, Christian; Giere, Wolfgang; Loch, Ernst-Gerhard; Rieck, Gisela

    2006-01-01

    Scientific evaluation is a fundamental tool of effective quality assurance of continuing medical education (CME). The analysis of the evaluation system of the CME academy of one the German Regional Medical Associations has revealed both the strengths and weaknesses of this system, thus enabling the installation of a model-like quality control system. Of utmost importance is the construction of an evaluation form that must be designed for good selectivity of the items, and the quality of the event should be well represented by the evaluating questions. For comparison purposes, the evaluation form should be standardized according to international evaluation standards. The standards of the German Society of Evaluation (DeGEval) and the guidelines and recommendations of the German Medical Association are both suitable orientational aids for the evaluation form and the evaluation process. The assessment process should also follow international standardised principles; it should be timely and subjective elements of interpretation should be eliminated, which is required for the evaluation of continuing medical education to achieve credibility. Furthermore, it is also a prerequisite that consequences may follow from the evaluation of continuing medical education and the continuity of the quality assurance process.

  16. Plutonium safe handling

    International Nuclear Information System (INIS)

    Tvehlov, Yu.

    2000-01-01

    The abstract, prepared on the basis of materials of the IAEA new leadership on the plutonium safe handling and its storage (the publication no. 9 in the Safety Reports Series), aimed at presenting internationally acknowledged criteria on the radiation danger evaluation and summarizing the experience in the safe management of great quantities of plutonium, accumulated in the nuclear states, is presented. The data on the weapon-class and civil plutonium, the degree of its danger, the measures for provision of its safety, including the data on accident radiation consequences with the fission number 10 18 , are presented. The recommendations, making it possible to eliminate the super- criticality danger, as well as ignition and explosion, to maintain the tightness of the facility, aimed at excluding the radioactive contamination and the possibility of internal irradiation, to provide for the plutonium security, physical protection and to reduce irradiation are given [ru

  17. The natural angle between the hand and handle and the effect of handle orientation on wrist radial/ulnar deviation during maximal push exertions.

    Science.gov (United States)

    Young, Justin G; Lin, Jia-Hua; Chang, Chien-Chi; McGorry, Raymond W

    2013-01-01

    The purpose of this experiment was to quantify the natural angle between the hand and a handle, and to investigate three design factors: handle rotation, handle tilt and between-handle width on the natural angle as well as resultant wrist radial/ulnar deviation ('RUD') for pushing tasks. Photographs taken of the right upper limb of 31 participants (14 women and 17 men) performing maximal seated push exertions on different handles were analysed. Natural hand/handle angle and RUD were assessed. It was found that all of the three design factors significantly affected natural handle angle and wrist RUD, but participant gender did not. The natural angle between the hand and the cylindrical handle was 65 ± 7°. Wrist deviation was reduced for handles that were rotated 0° (horizontal) and at the narrow width (31 cm). Handles that were tilted forward 15° reduced radial deviation consistently (12-13°) across handle conditions. Manual materials handling (MMH) tasks involving pushing have been related to increased risk of musculoskeletal injury. This study shows that handle orientation influences hand and wrist posture during pushing, and suggests that the design of push handles on carts and other MMH aids can be improved by adjusting their orientation to fit the natural interface between the hand and handle.

  18. IMPROVEMENT OF MANGOSTEEN FARMING AND POSTHARVEST HANDLING STRATEGIES BASED ON GLOBAL GAP STANDARD AT KIARA PEDES, PURWAKARTA DISTRICT

    Directory of Open Access Journals (Sweden)

    Nanda Erlangga

    2012-09-01

    Full Text Available The objectives of this research were (1 to determine the value chain of mangosteen at Kiara Pedes Sub district, Purwakarta District, (2 to identify the gap between actual condition at Kiara Pedes and Global GAP standard, (3 to identify internal and external factors that can affect the implementation strategy of Global GAP standards, and (4 to develop alternative strategies that can be applied to improve the system of mangosteen cultivation and post harvest handling based on Global GAP standards. The analytical tools being used in this study were value chain analysis, gap analysis, internal and external factor evaluation (IFE, EFE, IE matrix, SWOT analysis, and quantitative strategic planning matrix (QSPM. Identified primary actors in mangosteen value chain were farmers, middlemen, suppliers, exporters, and local and overseas retailers. Based on IE Matrix and SWOT analysis, the strategies to implement Global GAP standards were (a to increase mangosteen productivity and improve its quality by using developed cultivation and postharvest technology, (b to increase productivity, and improve quality and transportation network in accordance with Global GAP standard, (c to improve clean water and post-harvest infrastructure through cooperation with exporters and financial institutions, and (d to improve warehouse and supporting facilities such as packaging and sanitation according to the Global GAP standard for minimizing the environmental constraints. The most priority strategies from the QSPM analysis were improving clean water and post-harvest infrastructure through cooperation with exporters and financial institutions, followed by using the developed cultivation and postharvest technology to increase mangosteen productivity and improve its quality.Keywords: Mangosteen, Global GAP Standard, Value Chain, Improvement Strategies, Farming and Postharvest Handling Practices

  19. 9 CFR 3.118 - Handling.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Handling. 3.118 Section 3.118 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE ANIMAL WELFARE STANDARDS Specifications for the Humane Handling, Care, Treatment, and Transportation of Marine...

  20. Safety measuring for sodium handling

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ji Young; Jeong, K C; Kim, T J; Kim, B H; Choi, J H

    2001-09-01

    This is the report for the safety measures of sodium handling. These contents are prerequisites for the development of sodium technology and thus the workers participate in sodium handling and experiments have to know them perfectly. As an appendix, the relating parts of the laws are presented.

  1. A Perspective on Remote Handling Operations and Human Machine Interface for Remote Handling in Fusion

    International Nuclear Information System (INIS)

    Haist, B.; Hamilton, D.; Sanders, St.

    2006-01-01

    A large-scale fusion device presents many challenges to the remote handling operations team. This paper is based on unique operational experience at JET and gives a perspective on remote handling task development, logistics and resource management, as well as command, control and human-machine interface systems. Remote operations require an accurate perception of a dynamic environment, ideally providing the operators with the same unrestricted knowledge of the task scene as would be available if they were actually at the remote work location. Traditional camera based systems suffer from a limited number of viewpoints and also degrade quickly when exposed to high radiation. Virtual Reality and Augmented Reality software offer great assistance. The remote handling system required to maintain a tokamak requires a large number of different and complex pieces of equipment coordinating to perform a large array of tasks. The demands on the operator's skill in performing the tasks can escalate to a point where the efficiency and safety of operations are compromised. An operations guidance system designed to facilitate the planning, development, validation and execution of remote handling procedures is essential. Automatic planning of motion trajectories of remote handling equipment and the remote transfer of heavy loads will be routine and need to be reliable. This paper discusses the solutions developed at JET in these areas and also the trends in management and presentation of operational data as well as command, control and HMI technology development offering the potential to greatly assist remote handling in future fusion machines. (author)

  2. From quality markers to data mining and intelligence assessment: A smart quality-evaluation strategy for traditional Chinese medicine based on quality markers.

    Science.gov (United States)

    Bai, Gang; Zhang, Tiejun; Hou, Yuanyuan; Ding, Guoyu; Jiang, Min; Luo, Guoan

    2018-01-31

    The quality of traditional Chinese medicine (TCM) forms the foundation of its clinical efficacy. The standardization of TCM is the most important task of TCM modernization. In recent years, there has been great progress in the quality control of TCM. However, there are still many issues related to the current quality standards, and it is difficult to objectively evaluate and effectively control the quality of TCM. To face these challenge, we summarized the current quality marker (Q-marker) research based on its characteristics and benefits, and proposed a reasonable and intelligentized quality evaluation strategy for the development and application of Q-markers. Ultra-performance liquid chromatography-quadrupole/time-of-flight with partial least squares-discriminant analysis was suggested to screen the chemical markers from Chinese medicinal materials (CMM), and a bioactive-guided evaluation method was used to select the Q-markers. Near-infrared spectroscopy (NIRS), based on the distinctive wavenumber zones or points from the Q-markers, was developed for its determination. Then, artificial intelligence algorithms were used to clarify the complex relationship between the Q-markers and their integral functions. Internet and mobile communication technology helped us to perform remote analysis and determine the information feedback of test samples. The quality control research, evaluation, standard establishment and quality control of TCM must be based on the systematic analysis of Q-markers to study and describe the material basis of TCM efficacy, define the chemical markers in the plant body, and understand the process of herb drug acquisition, change and transmission laws affecting metabolism and exposure. Based on the advantages of chemometrics, new sensor technologies, including infrared spectroscopy, hyperspectral imaging, chemical imaging, electronic nose and electronic tongue, have become increasingly important in the quality evaluation of CMM. Inspired by the

  3. Image quality in conventional chest radiography. Evaluation using the postprocessing tool Diamond View

    International Nuclear Information System (INIS)

    Niemann, Tilo; Reisinger, Clemens; Rau, Philipp; Schwarz, Jochen; Ruis-Lopez, Laura; Bongartz, Georg

    2010-01-01

    The objective of this work was to evaluate the influence of the postprocessing tool Diamond View (Siemens AG Medical Solutions, Germany) on image quality in conventional chest radiography. Evaluation of image quality remains a challenge in conventional radiography. Based on the European Commission quality criteria we evaluated the improvement of image quality when applying the new postprocessing tool Diamond View (Siemens AG Medical solutions, Germany) to conventional chest radiographs. Three different readers prospectively evaluated 102 digital image pairs of chest radiographs. Statistical analysis was performed with a p value <0.05 considered as significant. Images were evaluated on basis of the modified imaging Quality Criteria by the Commission of the European Communities. Each of the 11 image quality criteria was evaluated separately using a five point classification. Statistical analysis showed an overall tendency for improved image quality for Diamond View (DV) for all criteria. Significant differences could be found in most of the criteria. In conclusion DV improves image quality in conventional chest radiographs.

  4. Quality Evaluation Scores are no more Reliable than Gestalt in Evaluating the Quality of Emergency Medicine Blogs: A METRIQ Study.

    Science.gov (United States)

    Thoma, Brent; Sebok-Syer, Stefanie S; Colmers-Gray, Isabelle; Sherbino, Jonathan; Ankel, Felix; Trueger, N Seth; Grock, Andrew; Siemens, Marshall; Paddock, Michael; Purdy, Eve; Kenneth Milne, William; Chan, Teresa M

    2018-01-30

    Construct: We investigated the quality of emergency medicine (EM) blogs as educational resources. Online medical education resources such as blogs are increasingly used by EM trainees and clinicians. However, quality evaluations of these resources using gestalt are unreliable. We investigated the reliability of two previously derived quality evaluation instruments for blogs. Sixty English-language EM websites that published clinically oriented blog posts between January 1 and February 24, 2016, were identified. A random number generator selected 10 websites, and the 2 most recent clinically oriented blog posts from each site were evaluated using gestalt, the Academic Life in Emergency Medicine (ALiEM) Approved Instructional Resources (AIR) score, and the Medical Education Translational Resources: Impact and Quality (METRIQ-8) score, by a sample of medical students, EM residents, and EM attendings. Each rater evaluated all 20 blog posts with gestalt and 15 of the 20 blog posts with the ALiEM AIR and METRIQ-8 scores. Pearson's correlations were calculated between the average scores for each metric. Single-measure intraclass correlation coefficients (ICCs) evaluated the reliability of each instrument. Our study included 121 medical students, 88 EM residents, and 100 EM attendings who completed ratings. The average gestalt rating of each blog post correlated strongly with the average scores for ALiEM AIR (r = .94) and METRIQ-8 (r = .91). Single-measure ICCs were fair for gestalt (0.37, IQR 0.25-0.56), ALiEM AIR (0.41, IQR 0.29-0.60) and METRIQ-8 (0.40, IQR 0.28-0.59). The average scores of each blog post correlated strongly with gestalt ratings. However, neither ALiEM AIR nor METRIQ-8 showed higher reliability than gestalt. Improved reliability may be possible through rater training and instrument refinement.

  5. Preliminary evaluation of different green payments in the handling of the nitrogen nutrition of the tomato by means of the Isotope 15 n

    International Nuclear Information System (INIS)

    Monederos, Milagros; Duennas, Graciela; Alfonso, C.A.; Hernandez, Marcela; Almeida, Grisel

    1999-01-01

    With the objective of evaluating in a preliminary way the effect of some leguminous ones (Leucaena, Canavalia, Crotalaria and Mucuna) used as green payments in the handling of the tomato nutrition its later validation under field conditions was carried out a rehearsal under controlled conditions and on a red ferralitic soils compact. I it determined the derived nitrogen of each source by means of the isotope 15N

  6. Quality Evaluation of Land-Cover Classification Using Convolutional Neural Network

    Science.gov (United States)

    Dang, Y.; Zhang, J.; Zhao, Y.; Luo, F.; Ma, W.; Yu, F.

    2018-04-01

    Land-cover classification is one of the most important products of earth observation, which focuses mainly on profiling the physical characters of the land surface with temporal and distribution attributes and contains the information of both natural and man-made coverage elements, such as vegetation, soil, glaciers, rivers, lakes, marsh wetlands and various man-made structures. In recent years, the amount of high-resolution remote sensing data has increased sharply. Accordingly, the volume of land-cover classification products increases, as well as the need to evaluate such frequently updated products that is a big challenge. Conventionally, the automatic quality evaluation of land-cover classification is made through pixel-based classifying algorithms, which lead to a much trickier task and consequently hard to keep peace with the required updating frequency. In this paper, we propose a novel quality evaluation approach for evaluating the land-cover classification by a scene classification method Convolutional Neural Network (CNN) model. By learning from remote sensing data, those randomly generated kernels that serve as filter matrixes evolved to some operators that has similar functions to man-crafted operators, like Sobel operator or Canny operator, and there are other kernels learned by the CNN model that are much more complex and can't be understood as existing filters. The method using CNN approach as the core algorithm serves quality-evaluation tasks well since it calculates a bunch of outputs which directly represent the image's membership grade to certain classes. An automatic quality evaluation approach for the land-cover DLG-DOM coupling data (DLG for Digital Line Graphic, DOM for Digital Orthophoto Map) will be introduced in this paper. The CNN model as an robustness method for image evaluation, then brought out the idea of an automatic quality evaluation approach for land-cover classification. Based on this experiment, new ideas of quality evaluation

  7. Quality Quantification of Evaluated Cross Section Covariances

    International Nuclear Information System (INIS)

    Varet, S.; Dossantos-Uzarralde, P.; Vayatis, N.

    2015-01-01

    Presently, several methods are used to estimate the covariance matrix of evaluated nuclear cross sections. Because the resulting covariance matrices can be different according to the method used and according to the assumptions of the method, we propose a general and objective approach to quantify the quality of the covariance estimation for evaluated cross sections. The first step consists in defining an objective criterion. The second step is computation of the criterion. In this paper the Kullback-Leibler distance is proposed for the quality quantification of a covariance matrix estimation and its inverse. It is based on the distance to the true covariance matrix. A method based on the bootstrap is presented for the estimation of this criterion, which can be applied with most methods for covariance matrix estimation and without the knowledge of the true covariance matrix. The full approach is illustrated on the 85 Rb nucleus evaluations and the results are then used for a discussion on scoring and Monte Carlo approaches for covariance matrix estimation of the cross section evaluations

  8. Demonstration of a remotely operated TRU waste size-reduction and material handling process

    International Nuclear Information System (INIS)

    Stewart, J.A. III; Schuler, T.F.; Ward, C.R.

    1986-01-01

    Noncombustible Pu-238 and Pu-239 waste is generated as a result of normal operation and decommissioning activity at the Savannah River Plant and is being retrievably stored at the site. As part of the long-term plan to process the stored waste and current waste for permanent disposal, a remote size-reduction and material handling process is being tested at Savannah River Laboratory to provide design support for the plant TRU Waste Facility scheduled to be completed in 1993. The process consists of a large, low-speed shredder and material handling system, a remote worktable, a bagless transfer system, and a robotically controlled manipulator, or Telerobot. Initial testing of the shredder and material handling system and a cycle test of the bagless transfer system were completed. Initial Telerobot run-in and system evaluation was completed. User software was evaluated and modified to support complete menu-driven operation. Telerobot prototype size-reduction tooling was designed and successfully tested. Complete nonradioactive testing of the equipment is scheduled to be completed in 1987

  9. Experience with fuel damage caused by abnormal conditions in handling and transporting operations

    International Nuclear Information System (INIS)

    Bailey, W.J.

    1983-01-01

    Pacific Northwest Laboratory (PNL) conducted a study to determine the expected condition of spent USA light-water reactor (LWR) fuel upon arrival at interim storage or fuel reprocessing facilities or, if fuel is declared a waste, at disposal facilities. Initial findings were described in an earlier PNL paper at PATRAM '80 and in a report. Updated findings are described in this paper, which includes an evaluation of information obtained from the literature and a compilation of cases of known or suspected damage to fuel as a result of handling and/or transporting operations. To date, PNL has evaluated 123 actual cases (98 USA and 25 non-USA). Irradiated fuel was involved in all but 10 of the cases. From this study, it is calculated that the frequency of unusual occurrences involving fuel damage from handling and transporting operations has been low. The damage that did occur was generally minor. The current base of experience with fuel handling and transporting operations indicates that nearly all of these unusual occurrences had only a minor or negligible effect on spent fuel storage facility operations

  10. Subjective Evaluation of Vocal Quality in Nasal Polyposis

    Directory of Open Access Journals (Sweden)

    Ziya Saltürk

    2014-12-01

    Full Text Available Aim: Nose is a resonator organ in production of voice. The aim of this study was to evaluate the effects of nasal obstruction caused by nasal polyposis on voice quality subjectively. Methods: Thirty-six patients diagnosed with nasal polyposis were included in the study. The 30-item voice handicap index 30 was used in order to evaluate subjective status of voice. Nasal endoscopy and computed tomography imaging of the paranasal sinuses were performed for each patient. Lund-Kennedy endoscopy scores and Lund-MacKay computed tomography scores were evaluated. Control group composed of 20 healthy subjects. Results: The mean voice handicap score in the patient group was 43.16 (SD 15.53 and it was 2.15 (SD 1.92 in control group. There was a statistically significant difference between the groups (p=0.001. The mean Lund-Kennedy and Lund-Mackay scores were 8.58 (SD 2.5 and 17 (SD 5.52, respectively. It was found that increased severity of nasal polyposis was the cause for decreased satisfaction with voice quality. Conclusion: Nasal obstruction caused by nasal polyposis affects voice quality adversely and as the severity of nasal polyposis increases, satisfaction with voice quality decreases.

  11. Evaluating the quality of perinatal anxiety information available online.

    Science.gov (United States)

    Kirby, Paige L; Reynolds, Kristin A; Walker, John R; Furer, Patricia; Pryor, Teaghan A M

    2018-06-22

    The Internet is an easily accessible source of information for women experiencing anxiety in pregnancy and/or postpartum to use when seeking health information. However, the Internet has several drawbacks, including inaccurate content that may be perceived as being accurate, non-biased, and evidence-based. Prior research indicates that anxiety and postpartum mental health websites have poor quality in terms of describing treatment options. There is a lack of research and knowledge in the area of perinatal anxiety, and an absence of research evaluating perinatal anxiety websites. The purpose of this study was to evaluate the quality of information regarding perinatal anxiety available on the Internet. Websites concerning perinatal anxiety were selected using the Google search engine. Each website was evaluated based on quality of health information, website usability, and readability. The 20 websites included in this study had low to moderate quality scores based on the DISCERN tool. There were no associations found between website order and website quality, or between website readability and website quality. Many websites had high PEMAT scores for the understandability section, which included content, style, and layout of information; however, most did not use visual aids to enhance comprehension. Most websites had low actionability scores, suggesting that information may not be useful in describing what actions may be taken to manage perinatal anxiety. This study highlights the need for high-quality websites concerning perinatal anxiety that are easy to navigate and provide the public with evidence-based information.

  12. Water quality evaluation of Al-Gharraf river by two water quality indices

    Science.gov (United States)

    Ewaid, Salam Hussein

    2017-11-01

    Water quality of Al-Gharraf river, the largest branch of Tigris River south of Iraq, was evaluated by the National Sanitation Foundation Water Quality Index (NFS WQI) and the Heavy Metal Pollution Index (HPI) depending on 13 physical, chemical, and biological parameters of water quality measured monthly at ten stations on the river during 2015. The NSF-WQI range obtained for the sampling sites was 61-70 indicating a medium water quality. The HPI value was 98.6 slightly below the critical value for drinking water of 100, and the water quality in the upstream stations is better than downstream due to decrease in water and the accumulation of contaminants along the river. This study explains the significance of applying the water quality indices that show the aggregate impact of ecological factors in charge of water pollution of surface water and which permits translation of the monitoring data to assist the decision makers.

  13. Asthma, guides for diagnostic and handling

    International Nuclear Information System (INIS)

    Salgado, Carlos E; Caballero A, Andres S; Garcia G, Elizabeth

    1999-01-01

    The paper defines the asthma, includes topics as diagnostic, handling of the asthma, special situations as asthma and pregnancy, handling of the asthmatic patient's perioperatory and occupational asthma

  14. Barriers and Facilitators to Safe Food Handling among Consumers: A Systematic Review and Thematic Synthesis of Qualitative Research Studies.

    Directory of Open Access Journals (Sweden)

    Ian Young

    Full Text Available Foodborne illness has a substantial health and economic burden on society, and most cases are believed to be due to unsafe food handling practices at home. Several qualitative research studies have been conducted to investigate consumers' perspectives, opinions, and experiences with safe food handling at home, and these studies provide insights into the underlying barriers and facilitators affecting their safe food handling behaviours. We conducted a systematic review of previously published qualitative studies in this area to synthesize the main across-study themes and to develop recommendations for future consumer interventions and research. The review was conducted using the following steps: comprehensive search strategy; relevance screening of abstracts; relevance confirmation of articles; study quality assessment; thematic synthesis of the results; and quality-of-evidence assessment. A total of 39 relevant articles reporting on 37 unique qualitative studies were identified. Twenty-one barriers and 10 facilitators to safe food handling were identified, grouped across six descriptive themes: confidence and perceived risk; knowledge-behaviour gap; habits and heuristics; practical and lifestyle constraints; food preferences; and societal and social influences. Our overall confidence that each barrier and facilitator represents the phenomenon of interest was rated as high (n = 11, moderate (11, and low (9. Overarching analytical themes included: 1 safe food handling behaviours occur as part of a complex interaction of everyday consumer practices and habituation; 2 most consumers are not concerned about food safety and are generally not motivated to change their behaviours based on new knowledge about food safety risks; and 3 consumers are amenable to changing their safe food handling habits through relevant social pressures. Key implications and recommendations for research, policy and practice are discussed.

  15. Barriers and Facilitators to Safe Food Handling among Consumers: A Systematic Review and Thematic Synthesis of Qualitative Research Studies

    Science.gov (United States)

    Young, Ian; Waddell, Lisa

    2016-01-01

    Foodborne illness has a substantial health and economic burden on society, and most cases are believed to be due to unsafe food handling practices at home. Several qualitative research studies have been conducted to investigate consumers’ perspectives, opinions, and experiences with safe food handling at home, and these studies provide insights into the underlying barriers and facilitators affecting their safe food handling behaviours. We conducted a systematic review of previously published qualitative studies in this area to synthesize the main across-study themes and to develop recommendations for future consumer interventions and research. The review was conducted using the following steps: comprehensive search strategy; relevance screening of abstracts; relevance confirmation of articles; study quality assessment; thematic synthesis of the results; and quality-of-evidence assessment. A total of 39 relevant articles reporting on 37 unique qualitative studies were identified. Twenty-one barriers and 10 facilitators to safe food handling were identified, grouped across six descriptive themes: confidence and perceived risk; knowledge-behaviour gap; habits and heuristics; practical and lifestyle constraints; food preferences; and societal and social influences. Our overall confidence that each barrier and facilitator represents the phenomenon of interest was rated as high (n = 11), moderate (11), and low (9). Overarching analytical themes included: 1) safe food handling behaviours occur as part of a complex interaction of everyday consumer practices and habituation; 2) most consumers are not concerned about food safety and are generally not motivated to change their behaviours based on new knowledge about food safety risks; and 3) consumers are amenable to changing their safe food handling habits through relevant social pressures. Key implications and recommendations for research, policy and practice are discussed. PMID:27907161

  16. Remote-handled transuranic system assessment appendices. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-01

    Volume 2 of this report contains six appendices to the report: Inventory and generation of remote-handled transuranic waste; Remote-handled transuranic waste site storage; Characterization of remote-handled transuranic waste; RH-TRU waste treatment alternatives system analysis; Packaging and transportation study; and Remote-handled transuranic waste disposal alternatives.

  17. Remote-handled transuranic system assessment appendices. Volume 2

    International Nuclear Information System (INIS)

    1995-11-01

    Volume 2 of this report contains six appendices to the report: Inventory and generation of remote-handled transuranic waste; Remote-handled transuranic waste site storage; Characterization of remote-handled transuranic waste; RH-TRU waste treatment alternatives system analysis; Packaging and transportation study; and Remote-handled transuranic waste disposal alternatives

  18. Contamination confinement system of irradiated materials handling laboratories

    International Nuclear Information System (INIS)

    Lobao, A. dos S.T.; Araujo, J.A. de; Camilo, R.L.

    1988-06-01

    A study to prevent radioctivity release in lab scale is presented. As a basis for the design all the limits established by the IAEA for ventilation systems were observed. An evaluation of the different parameters involved in the design have been made, resulting in the especification of the working areas, ducts and filtering systems in order to get the best conditions for the safe handling of irradiated materials. (author) [pt

  19. Hypothenar hammer syndrome from ice hockey stick-handling.

    Science.gov (United States)

    Zayed, Mohamed A; McDonald, Joey; Tittley, Jacques G

    2013-11-01

    Ulnar artery thrombosis and hypothenar hammer syndrome are rare vascular complications that could potentially occur with repeated blows or trauma to the hand. Although initially reported as an occupational hazard among laborers and craftsmen, it has been observed more recently among recreationalists and athletes. Until now, it has never been reported as a complication in ice hockey players. In this case report, a 26-year-old Canadian professional ice hockey player presented with acute dominant right hand paleness, coolness, and pain with hand use. The patient used a wooden hockey stick with a large knob of tape at the end of the handle, which he regularly gripped in the palm of his right hand to help with face-offs and general stick-handling. Sonographic evaluation demonstrated no arterial flow in the distal right ulnar artery distribution, and ulnar artery occlusion with no aneurysmal degeneration was confirmed by magnetic resonance angiogram. Intraarterial thrombolytic therapy was initiated, and subsequent serial angiograms demonstrated significant improvement in distal ulnar artery flow as well as recanalization of right hand deep palmar arch and digital arteries. The patient's symptoms resolved, and he was maintained on therapeutic anticoagulation for 3 months prior to returning to playing ice hockey professionally, but with a padded glove and no tape knob at the handle tip. This case highlights a unique presentation of hockey stick-handling causing ulnar artery thrombosis that was likely from repeated palmar hypothenar trauma. Appropriate diagnostic imaging, early intraarterial thrombolysis, and postoperative surveillance and follow-up were crucial for the successful outcome in this patient. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Test plan for FY-91 alpha CAM evaluation

    International Nuclear Information System (INIS)

    Winberg, M.R.

    1991-03-01

    This report describes the test plan for evaluating the Merlin Gerin, Inc., Edgar alpha continuous air monitor (CAM) and associated analysis system to be conducted by Idaho National Engineering Laboratory (INEL) for the Department of Energy. INEL has evaluated other commercial alpha CAM systems to detect transuranic contaminants during waste handling and retrieval operations. This test plan outlines experimental methods, sampling methods, sampling and analysis techniques, and equipment needed and safety and quality requirements to test the commercial CAM. 8 refs., 3 figs

  1. DDOS ATTACK DETECTION SIMULATION AND HANDLING MECHANISM

    Directory of Open Access Journals (Sweden)

    Ahmad Sanmorino

    2013-11-01

    Full Text Available In this study we discuss how to handle DDoS attack that coming from the attacker by using detection method and handling mechanism. Detection perform by comparing number of packets and number of flow. Whereas handling mechanism perform by limiting or drop the packets that detected as a DDoS attack. The study begins with simulation on real network, which aims to get the real traffic data. Then, dump traffic data obtained from the simulation used for detection method on our prototype system called DASHM (DDoS Attack Simulation and Handling Mechanism. From the result of experiment that has been conducted, the proposed method successfully detect DDoS attack and handle the incoming packet sent by attacker.

  2. Effect of phytosanitary irradiation on the postharvest quality of Seedless Kishu mandarins (Citrus kinokuni mukakukishu)

    Science.gov (United States)

    ‘Seedless Kishu’ mandarins (Citrus kinokuni mukakukishu) were treated with gamma irradiation at 150, 400, or 1000 Gy and stored for three weeks at 6°C and then for one week at 20°C to simulate commercial handling and marketing. The quality of the fruit was then evaluated following storage using non-...

  3. Report. no. 20. Sensory evaluation of indoor air quality

    DEFF Research Database (Denmark)

    Berglund, Birgitta; Bluyssen, Philomena; Clausen, Geo

    Human subjects are indispensable in the measurement of perceived indoor air quality. Chemical and physical methods of characterisation often are insensitive to odorous and sensory irritating air pollutants, or do not take account of combinations of singular pollutants in a biologically meaningful...... way. Therefore, sensory methods many times are the only or the preferred tool for evaluation of perceived indoor air quality. This report presents background to and advice on methodologies for sensory evaluation of perceived indoor air quality. It proposes methods which apply to source assessments...... as well as field investigations. The methods will assist in labelling of building materials, characterising air quality in indoor spaces, controlling ventilation performance, and measuring occupant responses in questionnaire field studies of the sick building syndrome. The proposed methods will enable...

  4. 7 CFR 981.42 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 981.42 Section 981.42 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in this...

  5. Basic approaches for the handling of illnesses of the cultivation of the rice

    International Nuclear Information System (INIS)

    Tapiero Ortiz, A.L.

    2001-01-01

    Some basic concepts are exposed for the handling of illnesses in the cultivation of the rice, beginning with the illness definition in the plants, integrating the concept in a system plant-pathogen-environment that in turn would have the subsystem it plants, subsystem pathogen and subsystem environmental conditions. It discusses each one of these subsystems and their influence in the development of the infection. The illnesses of the rice are described taken place by the mushrooms Pyricularia oryzae and Rizoctonia solani and the resistance and receptivity to the pathogens on the part of genetic materials, as well as it influences of the environment and indications are given for their handling. The spotted of the grain of the rice like an illness is described caused by a complex of mushrooms, bacteria and nutritional and climatic factors that cause decrease in the yield and they reduce the quality of the grain and the seed. They are related the pathogens organisms causing the illness, the influence of the environment in their development and instructions are given for their handling

  6. Criticality Safety Evaluation Report for the Cold Vacuum Drying (CVD) Facility's Process Water Handling System

    International Nuclear Information System (INIS)

    KESSLER, S.F.

    2000-01-01

    This report addresses the criticality concerns associated with process water handling in the Cold Vacuum Drying Facility. The controls and limitations on equipment design and operations to control potential criticality occurrences are identified

  7. Reflections on Post-Evaluation of Baccalaureate Programs: Revisiting Education Quality

    Science.gov (United States)

    Jianrong, Sun

    2009-01-01

    This paper discusses the distinction between two types of educational quality: quality at the institutional level and quality at the student learning level. The key element for continuous institutional improvement after completion of the evaluation of institutional teaching should be on redefining quality in student learning and developing a…

  8. Preliminary study of a blanket handling device and evaluation of the feasibility of eliminating the spread of radioactive contamination

    International Nuclear Information System (INIS)

    Leger, D.; Djerassi, H.; Maupou, M.; Charruyer, P.; Salpietro, E.

    1988-01-01

    A study concerning progress and future development of the BLANKET HANDLING DEVICE of NET-DN tokamak and the related potentialities against contamination dispersal during handling of internal segments. To prevent the dust dispersion during the mantainance operations, there are three options: a Tight-Intermediate Containment (TIC), a Containment Transfer Unit (CTU) or the dust fixation on the internal components. The design of the BHD takes account of multivarious dimensioning requirements (geometrical and dimensional constraints, including characteristics of the segments and torus), environmental and operational constraints (safety, lifetime, maintainability, cooling of Blanket segments, containment). The possible solutions concerning protection of special devices, during handling and travelling, are discussed

  9. [Spatial evaluation on ecological and aesthetic quality of Beijing agricultural landscape].

    Science.gov (United States)

    Pan, Ying; Xiao, He; Yu, Zhen-Rong

    2009-10-01

    A total of ten single indices mainly reflecting the ecological and aesthetic quality of agricultural landscape, including ecosystem function, naturalness, openness and diversity, contamination probability, and orderliness were selected, their different weights were given based on field survey and expert system, and an integrated evaluation index system of agricultural landscape quality was constructed. In the meantime, the land use data provided by GIS and the remote sensing data of vegetation index were used to evaluate the Beijing agricultural landscape quality and its spatial variation. There was a great spatial variation in the agricultural landscape quality of Beijing, being worse at the edges of urban area and towns, but better in suburbs. The agricultural landscape quality was mainly related to topography and human activity. To construct a large-scale integrated index system based on remote sensing data and landscape indices would have significance in evaluating the spatial variation of agricultural landscape quality.

  10. Evaluating supplier quality performance using fuzzy analytical hierarchy process

    Science.gov (United States)

    Ahmad, Nazihah; Kasim, Maznah Mat; Rajoo, Shanmugam Sundram Kalimuthu

    2014-12-01

    Evaluating supplier quality performance is vital in ensuring continuous supply chain improvement, reducing the operational costs and risks towards meeting customer's expectation. This paper aims to illustrate an application of Fuzzy Analytical Hierarchy Process to prioritize the evaluation criteria in a context of automotive manufacturing in Malaysia. Five main criteria were identified which were quality, cost, delivery, customer serviceand technology support. These criteria had been arranged into hierarchical structure and evaluated by an expert. The relative importance of each criteria was determined by using linguistic variables which were represented as triangular fuzzy numbers. The Center of Gravity defuzzification method was used to convert the fuzzy evaluations into their corresponding crisps values. Such fuzzy evaluation can be used as a systematic tool to overcome the uncertainty evaluation of suppliers' performance which usually associated with human being subjective judgments.

  11. Radiological safety aspects of handling plutonium

    International Nuclear Information System (INIS)

    Sundararajan, A.R.

    2016-01-01

    Department of Atomic Energy in its scheme of harnessing the nuclear energy for electrical power generation and strategic applications has given a huge role to utilization of plutonium. In the power production programme, fast reactors with plutonium as fuel are expected to play a major role. This would require establishing fuel reprocessing plants to handle both thermal and fast reactor fuels. So in the nuclear fuel cycle facilities variety of chemical, metallurgical, mechanical operations have to be carried out involving significant inventories of "2"3"9 Pu and associated radionuclides. Plutonium is the most radiotoxic radionuclide and therefore any facility handling it has to be designed and operated with utmost care. Two problems of major concern in the protection of persons working in plutonium handling facilities are the internal exposure to the operating personnel from uptake of plutonium and transplutonic nuclides as they are highly radiotoxic and the radiation exposure of hands and eye lens during fuel fabrication operations especially while handling recycled high burn up plutonium. In view of the fact that annual limit for intake is very small for "2"3"9Pu and its radiation emission characteristics are such that it is a huge challenge for the health physicists to detect Pu in air and in workers. This paper discusses the principles and practices followed in providing radiological surveillance to workers in plutonium handling areas. The challenges in protecting the workers from receiving exposures to hands and eye lens in handling high burn up plutonium are also discussed. The sites having Pu fuel cycle facilities should have trained medical staff to handle cases involving excessive intake of plutonium. (author)

  12. Efficiency Evaluation of Handling of Geologic-Geophysical Information by Means of Computer Systems

    Science.gov (United States)

    Nuriyahmetova, S. M.; Demyanova, O. V.; Zabirova, L. M.; Gataullin, I. I.; Fathutdinova, O. A.; Kaptelinina, E. A.

    2018-05-01

    Development of oil and gas resources, considering difficult geological, geographical and economic conditions, requires considerable finance costs; therefore their careful reasons, application of the most perspective directions and modern technologies from the point of view of cost efficiency of planned activities are necessary. For ensuring high precision of regional and local forecasts and modeling of reservoirs of fields of hydrocarbonic raw materials, it is necessary to analyze huge arrays of the distributed information which is constantly changing spatial. The solution of this task requires application of modern remote methods of a research of the perspective oil-and-gas territories, complex use of materials remote, nondestructive the environment of geologic-geophysical and space methods of sounding of Earth and the most perfect technologies of their handling. In the article, the authors considered experience of handling of geologic-geophysical information by means of computer systems by the Russian and foreign companies. Conclusions that the multidimensional analysis of geologicgeophysical information space, effective planning and monitoring of exploration works requires broad use of geoinformation technologies as one of the most perspective directions in achievement of high profitability of an oil and gas industry are drawn.

  13. Enclosure for handling high activity materials

    International Nuclear Information System (INIS)

    Jimeno de Osso, F.

    1977-01-01

    One of the most important problems that are met at the laboratories producing and handling radioisotopes is that of designing, building and operating enclosures suitable for the safe handling of active substances. With this purpose in mind, an enclosure has been designed and built for handling moderately high activities under a shielding made of 150 mm thick lead. In this report a description is given of those aspects that may be of interest to people working in this field. (Author)

  14. Enclosure for handling high activity materials

    Energy Technology Data Exchange (ETDEWEB)

    Jimeno de Osso, F

    1977-07-01

    One of the most important problems that are met at the laboratories producing and handling radioisotopes is that of designing, building and operating enclosures suitable for the safe handling of active substances. With this purpose in mind, an enclosure has been designed and built for handling moderately high activities under a shielding made of 150 mm thick lead. In this report a description is given of those aspects that may be of interest to people working in this field. (Author)

  15. Professional women's evaluation of the quality of career wear ...

    African Journals Online (AJOL)

    Firstly, quality is evaluated during the decision-making stage, and secondly during ... Both intrinsic and extrinsic product features play a role in the consumer's ... of the garment, directly influence the non-tangible quality indicators (emotional, ...

  16. SLSF loop handling system. Volume III. AISC code evaluations and analysis of critical attachments

    International Nuclear Information System (INIS)

    Ahmed, H.; Cowie, A.; Malek, R.A.; Rafer, A.; Ma, D.; Tebo, F.

    1978-10-01

    SLSF loop handling system was analyzed for deadweight and postulated dynamic loading conditions using a linear elastic static equivalent method of stress analysis. Stress computations of Cradle and critical attachments per AISC Code guidelines are presented. HFEF is credited with in-depth review of initial phase of work

  17. [Quality management in a clinical research facility: Evaluation of changes in quality in-house figures and the appraisal of in-house quality indicators].

    Science.gov (United States)

    Aden, Bile; Allekotte, Silke; Mösges, Ralph

    2016-12-01

    For long-term maintenance and improvement of quality within a clinical research institute, the implementation and certification of a quality management system is suitable. Due to the implemented quality management system according to the still valid DIN EN ISO 9001:2008 desired quality objectives are achieved effectively. The evaluation of quality scores and the appraisal of in-house quality indicators make an important contribution in this regard. In order to achieve this and draw quality assurance conclusions, quality indicators as sensible and sensitive as possible are developed. For this, own key objectives, the retrospective evaluation of quality scores, a prospective follow-up and also discussions establish the basis. In the in-house clinical research institute the measures introduced by the quality management led to higher efficiency in work processes, improved staff skills, higher customer satisfaction and overall to more successful outcomes in relation to the self-defined key objectives. Copyright © 2016. Published by Elsevier GmbH.

  18. Evaluation of groundwater and stream quality characteristics in the ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-06-17

    Jun 17, 2008 ... Key words: Evaluation, vicinity, stream quality, nitrate, Nigeria. ..... An assessment of the health and social economic implications of sachet water in Ibadan: A ... wastwater using the QUAL2E water quality model. Chemospere ...

  19. The Usability of SEEQ in Quality Evaluation of Arabic Secondary Education in Malaysia

    Science.gov (United States)

    al-Muslim, M.; Arifin, Zamri

    2015-01-01

    Evaluation of the quality of Arabic education in Malaysia needs to be conducted on a continuous basis to achieve the objectives of Arabic education. Student Evaluation of Education Quality (SEEQ) was proposed as one of the evaluation instruments of the quality of Arabic education. This study aimed to evaluate the usability of SEEQ in the context…

  20. Specialization and Flexibility in Port Cargo Handling

    Directory of Open Access Journals (Sweden)

    Hakkı KİŞİ

    2016-11-01

    Full Text Available Cargo handling appears to be the fundamental function of ports. In this context, the question of type of equipment and capacity rate need to be tackled with respect to cargo handling principles. The purpose of this study is to discuss the types of equipment to be used in ports, relating the matter to costs and capacity. The question is studied with a basic economic theoretical approach. Various conditions like port location, size, resources, cargo traffic, ships, etc. are given parameters to dictate the type and specification of the cargo handling equipment. Besides, a simple approach in the context of cost capacity relation can be useful in deciding whether to use specialized or flexible equipment. Port equipment is sometimes expected to be flexible to handle various types of cargo as many as possible and sometimes to be specialized to handle one specific type of cargo. The cases that might be suitable for those alternatives are discussed from an economic point of view in this article. Consequently, effectiveness and efficiency criteria play important roles in determining the handling equipment in ports.

  1. OpenKnowledge Deliverable 3.3.: A methodology for ontology matching quality evaluation

    OpenAIRE

    Yatskevich, Mikalai; Giunchiglia, Fausto; McNeill, Fiona; Shvaiko, Pavel

    2007-01-01

    This document presents an evaluation methodology for the assessment of quality results produced by ontology matchers. In particular, it discusses: (i) several standard quality measures used in the ontology matching evaluation, (ii) a methodology of how to build semiautomatically an incomplete reference alignment allowing for the assessment of quality results produced by ontology matchers and (iii) a preliminary empirical evaluation of the OpenKnowledge ontology matching component.

  2. Projection pursuit water quality evaluation model based on chicken swam algorithm

    Science.gov (United States)

    Hu, Zhe

    2018-03-01

    In view of the uncertainty and ambiguity of each index in water quality evaluation, in order to solve the incompatibility of evaluation results of individual water quality indexes, a projection pursuit model based on chicken swam algorithm is proposed. The projection index function which can reflect the water quality condition is constructed, the chicken group algorithm (CSA) is introduced, the projection index function is optimized, the best projection direction of the projection index function is sought, and the best projection value is obtained to realize the water quality evaluation. The comparison between this method and other methods shows that it is reasonable and feasible to provide decision-making basis for water pollution control in the basin.

  3. Water Quality Evaluation of the Yellow River Basin Based on Gray Clustering Method

    Science.gov (United States)

    Fu, X. Q.; Zou, Z. H.

    2018-03-01

    Evaluating the water quality of 12 monitoring sections in the Yellow River Basin comprehensively by grey clustering method based on the water quality monitoring data from the Ministry of environmental protection of China in May 2016 and the environmental quality standard of surface water. The results can reflect the water quality of the Yellow River Basin objectively. Furthermore, the evaluation results are basically the same when compared with the fuzzy comprehensive evaluation method. The results also show that the overall water quality of the Yellow River Basin is good and coincident with the actual situation of the Yellow River basin. Overall, gray clustering method for water quality evaluation is reasonable and feasible and it is also convenient to calculate.

  4. HMSRP Hawaiian Monk Seal Handling Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains records for all handling and measurement of Hawaiian monk seals since 1981. Live seals are handled and measured during a variety of events...

  5. A Tentative Study on the Evaluation of Community Health Service Quality*

    Science.gov (United States)

    Ma, Zhi-qiang; Zhu, Yong-yue

    Community health service is the key point of health reform in China. Based on pertinent studies, this paper constructed an indicator system for the community health service quality evaluation from such five perspectives as visible image, reliability, responsiveness, assurance and sympathy, according to service quality evaluation scale designed by Parasuraman, Zeithaml and Berry. A multilevel fuzzy synthetical evaluation model was constructed to evaluate community health service by fuzzy mathematics theory. The applicability and maneuverability of the evaluation indicator system and evaluation model were verified by empirical analysis.

  6. Evaluation of Quality Aspects in Vocational Training Programmes. Synthesis Report. CEDEFOP Document.

    Science.gov (United States)

    Seyfried, Erwin

    National evaluations of quality aspects of vocational training programs (VTPs) in five European countries--Belgium, Germany, France, Greece, and Portugal--were reviewed to determine how VTP quality is currently being evaluated and identify a more coherent approach to evaluating VTPs. Special attention was paid to how existing evaluation studies…

  7. Handling of Multimedia Files in the Invenio Software

    CERN Document Server

    Oltmanns, Björn; Schiefer, Bernhard

    Handling of multimedia files in the Invenio Software’ is motivated by the need for integration of multimedia files in the open-source, large-scale digital library software Invenio, developed and used at CERN, the European Organisation for Nuclear Research. In the last years, digital assets like pictures, presentations podcasts and videos became abundant in these systems and digital libraries have grown out of their classic role of only storing bibliographical metadata. The thesis focuses on digital video as a type of multimedia and covers the complete workflow of handling video material in the Invenio software: from the ingestion of digital video material to its processing on to the storage and preservation and finally the streaming and presentation of videos to the user. The potential technologies to realise a video submission workflow are discussed in-depth and evaluated towards system integration with Invenio. The focus is set on open and free technologies, which can be redistributed with the Inve...

  8. Fort St. Vrain fuel-handling system RAM analysis

    International Nuclear Information System (INIS)

    Azizi, S.M.; Berg, G.E.; Burton, J.H.; Durand, R.E.; Larson, E.M.; Pepe, D.J.; Rutherford, P.D.; Novachek, F.J.

    1989-01-01

    Public Service of Company of Colorado (PSC) is planning to decommission its Fort St. Vrain plant in 1990. This requires removal of 1,500 separate assemblies from the core. With the low historical availability of the fuel-handling system (FHS), defueling time was estimated at 36 months. With plant expenses of approximately $1.6 million per month during defueling, this would mean a schedule cost of $58 million. With their contractor, Rockwell International, PSC embarked on a reliability, availability, and maintainability (RAM) analysis to reduce projected defueling time. Key elements included (a) estimating availability of the FHS using a limited historical record, (b) assessing the defueling critical path, and (c) proposing and evaluating design/operational improvements. The most cost-effective improvements are being implemented and are expected to provide a reduction of >18 months in schedule and a net savings of $20 to 25 million. The paper describes the FHS design and operation, major problems associated with fuel-handling operations, and results and recommendations

  9. Patients' Evaluation of the Quality of Diabetes Care (PEQD)

    DEFF Research Database (Denmark)

    Pouwer, F; Snoek, Frank J

    2002-01-01

    aspects of the quality of diabetes care as delivered by the specialist in internal medicine (internist) and the diabetes nurse specialist (DNS). Two principal components analyses (internist/DNS) both yielded one 14 item factor with a high internal consistency. Satisfaction with diabetes care, fewer......OBJECTIVES: To develop a brief measure of patients' evaluation of the quality of diabetes care and to study predictors of consumers' rating of the quality of diabetes care. DESIGN: A prospective design. SUBJECTS: 176 adults with type 1 (39%) or type 2 (61%) diabetes. MAIN MEASURES: Demographic...... variables, HbA1c, number of diabetes complications, satisfaction with diabetes care, diabetes related distress, and fear of hypoglycaemia were assessed by self-report. In addition, satisfaction with diabetes care and evaluations about quality of the care were measured at 16 month follow up. Statistical...

  10. Quality Assurance program plan - plutonium stabilization and handling project W-460

    International Nuclear Information System (INIS)

    SCHULTZ, J.W.

    1999-01-01

    This Quality Assurance Program Plan (QAPP) identifies Project Quality Assurance (QA) program requirements for all parties participating in the design, procurement, demolition, construction, installation, inspection and testing for Project W-460

  11. [A quality evaluation tableau for health institutions: an educational tool].

    Science.gov (United States)

    Moll, Marie Christine; Decavel, Frédérique; Merlet, Christine

    2009-09-01

    For a few years, health institutions have had to comply with the certification and the need to establish the new governance. Thanks to the accreditation version 2 (obtained in 2005), the elaboration of the hospital project (adopted in October, 2006) and the organization in poles since 2006, the quality oriented management became a priority axis at the University Hospital of Angers. The strategic adaptation to quality requirements leads to develop the hospital management, more especially at the level of the clinical, medico technical and administrative poles. The elements of the hospital project including the part about the quality, risk and evaluation aim at being adapted by every pole according to the level of its project. This adaptation which is imposed to each pole manager requires a practical and educational accompaniment allowing at the same time to realize a diagnosis of the progress of the quality approach, a measure of the impact of the global impregnation within the institution and a comparison between pole. A eight axis dashboard with criteria and a user guide were developed from certification ISO 9001, the EFQM manual and the certification manual version 2 of the Healthcare High Authorities. The criteria are transcribed in an EXCEL grid ready to use. Succeeding in estimating your own quality system means that you demonstrate the maturity of the quality approach. The results of this evaluation confirmed those of the certification. The dashboard is a management structuring tool at the service of the multidisciplinary team. Two considerations emerge from these results: First of all, for the hospital top management, the axes to be improved emerge as a priority to determine and target the next annual action plans. The results also allow to support the auto evaluation for the certification version 2010 planned in January of the same year. It is a pragmatic tool which allows auto evaluation and comparison to estimate the pole performances. It is a strategic

  12. Development and Quality Evaluation of a Non-Alcoholic Beverage ...

    African Journals Online (AJOL)

    Development and Quality Evaluation of a Non-Alcoholic Beverage from Cocoyam ( Xanthosoma sagittifolium and Colocasia esculenta ) ... Nigerian Food Journal ... evaluation were conducted on the products to assess the highest preference.

  13. An Empirical Analysis of Stakeholders' Influence on Policy Development: the Role of Uncertainty Handling

    Directory of Open Access Journals (Sweden)

    Rianne M. Bijlsma

    2011-03-01

    Full Text Available Stakeholder participation is advocated widely, but there is little structured, empirical research into its influence on policy development. We aim to further the insight into the characteristics of participatory policy development by comparing it to expert-based policy development for the same case. We describe the process of problem framing and analysis, as well as the knowledge base used. We apply an uncertainty perspective to reveal differences between the approaches and speculate about possible explanations. We view policy development as a continuous handling of substantive uncertainty and process uncertainty, and investigate how the methods of handling uncertainty of actors influence the policy development. Our findings suggest that the wider frame that was adopted in the participatory approach was the result of a more active handling of process uncertainty. The stakeholders handled institutional uncertainty by broadening the problem frame, and they handled strategic uncertainty by negotiating commitment and by including all important stakeholder criteria in the frame. In the expert-based approach, we observed a more passive handling of uncertainty, apparently to avoid complexity. The experts handled institutional uncertainty by reducing the scope and by anticipating windows of opportunity in other policy arenas. Strategic uncertainty was handled by assuming stakeholders' acceptance of noncontroversial measures that balanced benefits and sacrifices. Three other observations are of interest to the scientific debate on participatory policy processes. Firstly, the participatory policy was less adaptive than the expert-based policy. The observed low tolerance for process uncertainty of participants made them opt for a rigorous "once and for all" settling of the conflict. Secondly, in the participatory approach, actors preferred procedures of traceable knowledge acquisition over controversial topics to handle substantive uncertainty. This

  14. Web wisdom how to evaluate and create information quality on the Web

    CERN Document Server

    Alexander, Janet E

    1999-01-01

    Web Wisdom is an essential reference for anyone needing to evaluate or establish information quality on the World Wide Web. The book includes easy to use checklists for step-by-step quality evaluations of virtually any Web page. The checklists can also be used by Web authors to help them ensure quality information on their pages. In addition, Web Wisdom addresses other important issues, such as understanding the ways that advertising and sponsorship may affect the quality of Web information. It features: * a detailed discussion of the items involved in evaluating Web information; * checklists

  15. Development of the Simulation Program for the In-Vessel Fuel Handling System of Double Rotating Plug Type

    International Nuclear Information System (INIS)

    Kim, S. H.; Kim, J. B.

    2011-01-01

    In-vessel fuel handling machines are the main equipment of the in-vessel fuel handling system, which can move the core assembly inside the reactor vessel along with the rotating plug during refueling. The in vessel fuel handling machines for an advanced sodium cooled fast reactor(SFR) demonstration plant are composed of a direct lift machine(DM) and a fixed arm machine(FM). These machines should be able to access all areas above the reactor core by means of the rotating combination of double rotating plugs. Thus, in the in vessel fuel handling system of the double rotating plug type, it is necessary to decide the rotating plug size and evaluate the accessibility of in-vessel fuel handling machines in given core configuration. In this study, the simulation program based on LABVIEW which can effectively perform the arrangement design of the in vessel fuel handling system and simulate the rotating plug motion was developed. Fig. 1 shows the flow chart of the simulation program

  16. Advanced robotics handling and controls applied to Mixed Waste characterization, segregation and treatment

    International Nuclear Information System (INIS)

    Grasz, E.; Huber, L.; Horvath, J.; Roberson, P.; Wilhelmsen, K.; Ryon, R.

    1994-11-01

    At Lawrence Livermore National Laboratory under the Mixed Waste Operations program of the Department of Energy Robotic Technology Development Program (RTDP), a key emphasis is developing a total solution to the problem of characterizing, handling and treating complex and potentially unknown mixed waste objects. LLNL has been successful at looking at the problem from a system perspective and addressing some of the key issues including non-destructive evaluation of the waste stream prior to the materials entering the handling workcell, the level of automated material handling required for effective processing of the waste stream objects (both autonomous and tele-operational), and the required intelligent robotic control to carry out the characterization, segregation, and waste treating processes. These technologies were integrated and demonstrated in a prototypical surface decontamination workcell this past year

  17. Image processing system performance prediction and product quality evaluation

    Science.gov (United States)

    Stein, E. K.; Hammill, H. B. (Principal Investigator)

    1976-01-01

    The author has identified the following significant results. A new technique for image processing system performance prediction and product quality evaluation was developed. It was entirely objective, quantitative, and general, and should prove useful in system design and quality control. The technique and its application to determination of quality control procedures for the Earth Resources Technology Satellite NASA Data Processing Facility are described.

  18. Integral Criteria for Measuring the Quality of Teacher Evaluation

    Directory of Open Access Journals (Sweden)

    Olga Navickienė

    2012-07-01

    Full Text Available Purpose—To construct the knowledge evaluation quality integral criteria, which allows to ascertain whether the different teachers properly assess the students’ knowledge. The criteria has been tested setting up the educational experiment and examining the six mathematics lecturers’ assessments.Design/methodology/approach—This research involved the Mykolas Romeris University students of Public Administration degree second year and Management of Organizations degree first year. The test questions for students were designed using the mathematical knowledge assessment information system, which allows for closed-ended mathematical test, to obtain statistical data about test takers, to perform quality analysis of the test; in the middle and the end of the semester.Findings—The construction technique for the evaluation quality criteria of the students’ working results assessment, which were performed by six different lecturers, during practical trainings, seminars, laboratory and other sessions is proposed in this article.Research limitations/implications—The constructed evaluation criteria is universal: it does not depend on the particular subject; it can be applied to several groups, courses or lecturers. It depends on three calculated indicators I, S, K, which show in two ways obtained estimates of the measured information compatibility of degrees, marks matching and correlation terms.Practical implications—The integral criteria has been tested examining the six mathematics lecturers’ assessments.Originality/Value—Constructing the criteria have been used the educational measurement models of authors of this article and other researchers, however its’ connection to general (integral criteria, best of authors’ knowledge, is original and have not be researched before.Keywords: knowledge evaluation, quality of teacher evaluation, evaluation of teachers, mathematical modeling.Research type: research paper.

  19. Management of transport and handling contracts

    CERN Document Server

    Rühl, I

    2004-01-01

    This paper shall outline the content, application and management strategies for the various contracts related to transport and handling activities. In total, the two sections Logistics and Handling Maintenance are in charge of 27 (!) contracts ranging from small supply contracts to big industrial support contracts. The activities as well as the contracts can generally be divided into four main topics "Vehicle Fleet Management"; "Supply, Installation and Commissioning of Lifting and Hoisting Equipment"; "Equipment Maintenance" and "Industrial Support for Transport and Handling". Each activity and contract requires different approaches and permanent adaptation to the often changing CERN's requirements. In particular, the management and the difficulties experienced with the contracts E072 "Maintenance of lifting and hoisting equipment", F420 "Supply of seven overhead traveling cranes for LHC" and S090/S103 "Industrial support for transport and handling" will be explained in detail.

  20. Designing the model for evaluating business quality in Croatia

    Directory of Open Access Journals (Sweden)

    Ana Ježovita

    2015-01-01

    Full Text Available The main objective of the paper includes designing a model for evaluating the financial quality of business operations. In that context, for the paper purposes, the financial quality of business operations is defined as an ability to achieve adequate value of individual financial ratios for financial position and performance evaluation. The objective of the model is to obtain comprehensive conclusion about the financial quality of business operation using only value of the function. Data used for designing the model is limited to financial data available from the annual balance sheet and income statement. Those limitations offer the opportunity for all sizes of companies from the non-financial business economy sector to use the designed model for evaluation purposes. Statistical methods used for designing the model are multivariate discriminant analysis and logistic regression. Discriminant analysis resulted in the function which includes five individual financial ratios with the best discriminant power. Respecting the results obtained in the classification matrix with classification accuracy of 95.92% by the original sample, or accuracy of 96.06% for the independent sample, it can be concluded that it is possible to evaluate the financial quality of business operations of companies in Croatia by using the model composed of individual financial ratios. Conducted logistic regression confirms the results obtained using discriminant analysis.

  1. Clinical evaluation of a new set of image quality criteria for mammography

    International Nuclear Information System (INIS)

    Grahn, A.; Hemdal, B.; Andersson, I.; Ruschin, M.; Thilander-Klang, A.; Boerjesson, S.; Tingberg, A.; Mattsson, S.; Haakansson, M.; Baath, M.; Maansson, L. G.; Medin, J.; Wanninger, F.; Panzer, W.

    2005-01-01

    The European Commission (EC) quality criteria for screen-film mammography are used as a tool to asses image quality. A new set of criteria was developed and initially tested in a previous study. In the present study, these criteria are further evaluated using screen-film mammograms that have been digitised, manipulated to simulated different image quality level and reprinted on film. Expert radiologists have evaluated these manipulated to simulate different image quality levels and reprinted on film. Expert radiologists have evaluated these manipulated images using both the original (EC) and the new criteria. A comparison of three different simulated dose levels that the new criteria yield a larger separation of image criteria scores than the old ones. These results indicated that the new set of image quality criteria has a higher discriminative power than the old set and thus seems to be more suitable for evaluation of image quality in mammography. (authors)

  2. Ergonomics: safe patient handling and mobility.

    Science.gov (United States)

    Hallmark, Beth; Mechan, Patricia; Shores, Lynne

    2015-03-01

    This article reviews and investigates the issues surrounding ergonomics, with a specific focus on safe patient handling and mobility. The health care worker of today faces many challenges, one of which is related to the safety of patients. Safe patient handling and mobility is on the forefront of the movement to improve patient safety. This article reviews the risks associated with patient handling and mobility, and informs the reader of current evidence-based practice relevant to this area of care. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Remote handling equipment

    International Nuclear Information System (INIS)

    Clement, G.

    1984-01-01

    After a definition of intervention, problems encountered for working in an adverse environment are briefly analyzed for development of various remote handling equipments. Some examples of existing equipments are given [fr

  4. Robotics and remote handling concepts for disposal of high-level nuclear waste

    International Nuclear Information System (INIS)

    McAffee, Douglas; Raczka, Norman; Schwartztrauber, Keith

    1997-01-01

    This paper summarizes preliminary remote handling and robotic concepts being developed as part of the US Department of Energy's (DOE) Yucca Mountain Project. The DOE is currently evaluating the Yucca Mountain Nevada site for suitability as a possible underground geologic repository for the disposal of high level nuclear waste. The current advanced conceptual design calls for the disposal of more than 12,000 high level nuclear waste packages within a 225 km underground network of tunnels and emplacement drifts. Many of the waste packages may weigh as much as 66 tonnes and measure 1.8 m in diameter and 5.6 m long. The waste packages will emit significant levels of radiation and heat. Therefore, remote handling is a cornerstone of the repository design and operating concepts. This paper discusses potential applications areas for robotics and remote handling technologies within the subsurface repository. It also summarizes the findings of a preliminary technology survey which reviewed available robotic and remote handling technologies developed within the nuclear, mining, rail and industrial robotics and automation industries, and at national laboratories, universities, and related research institutions and government agencies

  5. Welding method by remote handling

    International Nuclear Information System (INIS)

    Hashinokuchi, Minoru.

    1994-01-01

    Water is charged into a pit (or a water reservoir) and an article to be welded is placed on a support in the pit by remote handling. A steel plate is disposed so as to cover the article to be welded by remote handling. The welding device is positioned to the portion to be welded and fixed in a state where the article to be welded is shielded from radiation by water and the steel plate. Water in the pit is drained till the portion to be welded is exposed to the atmosphere. Then, welding is conducted. After completion of the welding, water is charged again to the pit and the welding device and fixing jigs are decomposed in a state where the article to be welded is shielded again from radiation by water and the steel plate. Subsequently, the steel plate is removed by remote handling. Then, the article to be welded is returned from the pit to a temporary placing pool by remote handling. This can reduce operator's exposure. Further, since the amount of the shielding materials can be minimized, the amount of radioactive wastes can be decreased. (I.N.)

  6. Quality assurance and the sub-contract interface: co-operative evaluation

    International Nuclear Information System (INIS)

    Churchill, G.F.; Rippon, D.J.

    1977-01-01

    The CEGB standard QA 42-1 quality assurance programme requires purchasers to establish supplier selection and assessment procedures either by previous continuous record of supplying identical or equivalent material satisfactorily, or by an evaluation of the sub-contractors quality system. In order to avoid the multiple evaluations that the latter would involve for projects such as nuclear power stations, which concern a hierarchy of organisations, the idea of co-operative evaluations was suggested. The requirements involved in establishing co-operative evaluations are discussed. Some potential difficulties which have been identified from experience are described. (U.K.)

  7. Module-based quality system functionality evaluation in production logistics

    Energy Technology Data Exchange (ETDEWEB)

    Khabbazi, M.R.; Wikander, J.; Onori, M.; Maffei, A.; Chen, D.

    2016-07-01

    This paper addresses a comprehensive modeling and functionality evaluation of a module-based quality system in production logistics at the highest domain abstract level of business processes. All domain quality business processes and quality data transactions are modeled using BPMN and UML tools and standards at the business process and data modeling. A modular web-based prototype is developed to evaluate the models addressing the quality information system functionality requirements and modularity in production logistics through data scenarios and data queries. Using the object-oriented technique in design at the highest domain level, the proposed models are subject further development in the lower levels for the implementing case. The models are specifically able to manipulate all quality operations including remedy and control in a lot-based make-to-order production logistics system as an individual module. Due to the specification of system as domain design structure, all proposed BPMs, data models, and the actual database prototype are seen referential if not a solution as a practical “to-be” quality business process re-engineering template. This paper sets out to provide an explanatory approach using different practical technique at modeling steps as well as the prototype implementation. (Author)

  8. Civilsamfundets ABC: H for Handling

    DEFF Research Database (Denmark)

    Lund, Anker Brink; Meyer, Gitte

    2015-01-01

    Hvad er civilsamfundet? Anker Brink Lund og Gitte Meyer fra CBS Center for Civil Society Studies gennemgår civilsamfundet bogstav for bogstav. Vi er nået til H for Handling.......Hvad er civilsamfundet? Anker Brink Lund og Gitte Meyer fra CBS Center for Civil Society Studies gennemgår civilsamfundet bogstav for bogstav. Vi er nået til H for Handling....

  9. The technique on handling radiation

    International Nuclear Information System (INIS)

    1997-11-01

    This book describes measurement of radiation and handling radiation. The first part deals with measurement of radiation. The contents of this part are characteristic on measurement technique of radiation, radiation detector, measurement of energy spectrum, measurement of radioactivity, measurement for a level of radiation and county's statistics on radiation. The second parts explains handling radiation with treating of sealed radioisotope, treating unsealed source and radiation shield.

  10. Coal handling equipment - making the right choices in a competitive market

    Energy Technology Data Exchange (ETDEWEB)

    Dodds-Ely, L.

    2009-02-15

    Liebherr is a dominant crane supplier for coal-handling in Kalimantan, the main coal producing area of Indonesia. Since the delivery of the first heavy-duty, high-performance CBG from-rope grab cranes to Pulau Laut Coal Terminal and Balikpapan Coal Terminal ten years ago the number of fixed cargo cranes (FCC) operating on jetties and quaysides alone in Kalimantan has risen to no fewer than ten further orders in the pipeline, confirming the high quality and reliability of Liebherr's producers and the company's excellent reputation in the coal-handling business. The Liebherr CBG heavy-duty high-performance four-rope grab cranes are specially designed for continuous operation and ensure rapid and efficient turnover of all types of bulk cargo. With maximum lifting capacities of 30 tonnes at an outreach of 28 metres, each of the Balikpapan cranes achievers an hourly turnover of approximately ,000 tonnes. The article describes the key characteristics of the crane and its additional optimal features. 2 photos.

  11. Manual on safe production, transport, handling and storage of uranium hexafluoride

    International Nuclear Information System (INIS)

    1994-11-01

    This document includes a description of the physical, chemical and radiological properties of UF 6 and related products, including information concerning their production, handling, storage and transportation and the management of the wastes which result. All the operations of UF 6 management are considered form a safety point of view. The IAEA organized a series of meetings to consider the hazards of UF 6 transport since considerable quantities of depleted, natural and enriched UF 6 are transported between nuclear fuel sites. Storage of depleted UF 6 is another important issue. Factors affecting long term storage are presented, especially site choice and cylinder corrosion. Other topics such as waste management, quality assurance and emergency preparedness which contribute to the overall safety of UF 6 handling, are included. The intention of this document is to provide analysis of the safety implications of all stages of UF 6 operations and to draw attention to specific features and properties of importance. 38 refs, figs, tabs

  12. Hazardous Waste Cerification Plan: Hazardous Waste Handling Facility, Lawrence Berkeley Laboratory

    International Nuclear Information System (INIS)

    1992-02-01

    The purpose of this plan is to describe the organization and methodology for the certification of hazardous waste (HW) handled in the Lawrence Berkeley Laboratory (LBL) Hazardous Waste Handling Facility (HWHF). The plan also incorporates the applicable elements of waste reduction, which include both up-front minimization and end- product treatment to reduce the volume and toxicity of the waste; segregation of the waste as it applies to certification; and executive summary of the Quality Assurance Program Plan (QAPP) for the HWHF and a list of the current and planned implementing procedures used in waste certification. The plan provides guidance from the HWHF to waste generators, waste handlers, and the Systems Group Manager to enable them to conduct their activities and carry out their responsibilities in a manner that complies with several requirements of the Federal Resource Conservation and Resource Recovery Act (RCRA), the Federal Department of Transportation (DOT), and the State of California, Code of Regulations (CCR), Title 22

  13. Uranium hexafluoride handling

    International Nuclear Information System (INIS)

    1991-01-01

    The United States Department of Energy, Oak Ridge Field Office, and Martin Marietta Energy Systems, Inc., are co-sponsoring this Second International Conference on Uranium Hexafluoride Handling. The conference is offered as a forum for the exchange of information and concepts regarding the technical and regulatory issues and the safety aspects which relate to the handling of uranium hexafluoride. Through the papers presented here, we attempt not only to share technological advances and lessons learned, but also to demonstrate that we are concerned about the health and safety of our workers and the public, and are good stewards of the environment in which we all work and live. These proceedings are a compilation of the work of many experts in that phase of world-wide industry which comprises the nuclear fuel cycle. Their experience spans the entire range over which uranium hexafluoride is involved in the fuel cycle, from the production of UF 6 from the naturally-occurring oxide to its re-conversion to oxide for reactor fuels. The papers furnish insights into the chemical, physical, and nuclear properties of uranium hexafluoride as they influence its transport, storage, and the design and operation of plant-scale facilities for production, processing, and conversion to oxide. The papers demonstrate, in an industry often cited for its excellent safety record, continuing efforts to further improve safety in all areas of handling uranium hexafluoride

  14. Three-dimensional television system for remote handling

    International Nuclear Information System (INIS)

    Dumbreck, A.A.; Abel, E.

    1988-01-01

    The paper refers to work previously described on the development of 3-D Television Systems. 3-D TV had been developed with a view to proving whether it was a useful remote handling tool which would be easy to use and comfortable to view. The paper summarizes the work of evaluation trials at UK facilities and reviews the developments which have subsequently taken place. 3-D TV systems have been found to give improved performance in terms of speed and accuracy of operations and to reduce the number of camera views required. (author)

  15. Evaluation of a pilot fish handling system at Bruce NGS 'A'

    International Nuclear Information System (INIS)

    Griffiths, J.S.

    1985-10-01

    A pilot fish recovery system using a Hidrostal fish pump was tested in the Bruce NGS 'A' forebay during June, 1984. Despite low forebay fish concentrations, the system was capable of capturing 97,000 alewife/day (3900 kg) if operated continuously. Post-pumping survival averaged 97%. It is estimated that a single pump could handle alewife runs in the 40,000 to 70,000 kg range, but multiple pumps or a single larger pump would be required to assure station protection from the largest runs (>100,000 kg). Results indicate that tank/trailer return of pumped fish is feasible, but other alternatives for returning fish to Lake Huron are also being considered

  16. Assessing cow-calf welfare. Part 2: Risk factors for beef cow health and behavior and stockperson handling.

    Science.gov (United States)

    Simon, G E; Hoar, B R; Tucker, C B

    2016-08-01

    Epidemiological studies can be used to identify risk factors for livestock welfare concerns but have not been conducted in the cow-calf sector for this purpose. The objectives of this study were to investigate the relationships of 1) herd-level management, facilities, and producer perspectives with cattle health and behavior and stockperson handling and 2) stockperson handling on cattle behavior at the individual cow level. Cow ( = 3,065) health and behavior and stockperson handling during a routine procedure (e.g., pregnancy checks) were observed on 30 California ranches. Management and producer perspectives were evaluated using an interview, and handling facility features were recorded at the chute. After predictors were screened for univariable associations, multivariable models were built for cattle health (i.e., thin body condition, lameness, abrasions, hairless patches, swelling, blind eyes, and dirtiness) and behavior (i.e., balking, vocalizing, stumbling and falling in the chute and while exiting the restraint, and running out of the restraint) and stockperson handling (i.e., electric prod use, moving aid use, tail twisting, and mis-catching cattle). When producers empathized more toward an animal's pain experience, there was a lower risk of swelling (odds ratio [OR] = 0.7) but a higher risk of lameness (OR = 1.3), which may indicate a lack of awareness of the latter. Training stockpersons using the Beef Quality Assurance program had a protective effect on cow cleanliness and mis-catching in the restraint (OR = 0.2 and OR = 0.5, respectively). Hydraulic chutes increased the risk of vocalizations (OR = 2.7), possibly because these systems can apply greater pressure to the sides of the animal than manual restraints. When a moving aid was used to move an individual cow, it increased the risk of her balking, but when hands, in particular, were used, the risk of balking decreased across the herd (OR = 34.1 and OR = 0.3, respectively). Likewise, individual cows

  17. Internal dose evaluation of workers involved in radioisotopes and radiopharmaceuticals handling for medical use

    International Nuclear Information System (INIS)

    Cesar, R.B.P.; Mesquita, C.H. de

    1987-01-01

    The internal dose levels of IPEN workers, involved in the production of radioisotopes and radiopharmaceuticals for medical use are surveyed. In this production, the workers were splited in six group: research and development, routine production, quality control, packaging, radiological protection and maintenance. The internal dose was evaluated according to the models described by ICRP-30, from the results obtained in the whole body counters monitoring. (C.G.C.) [pt

  18. Handling Pyrophoric Reagents

    Energy Technology Data Exchange (ETDEWEB)

    Alnajjar, Mikhail S.; Haynie, Todd O.

    2009-08-14

    Pyrophoric reagents are extremely hazardous. Special handling techniques are required to prevent contact with air and the resulting fire. This document provides several methods for working with pyrophoric reagents outside of an inert atmosphere.

  19. Quality of care in reproductive health programmes: monitoring and evaluation of quality improvement.

    Science.gov (United States)

    Kwast, B E

    1998-12-01

    As 200 million women become pregnant every year, at least 30 million will develop life-threatening complications requiring emergency treatment at any level of society where they live. But it is a basic human right that pregnancy be made safe for all women as complications are mostly unpredictable. This requires reproductive health programmes which are responsive to women's and their families' needs and expectations on the one hand and enhancement of community participation, high quality obstetric services, and both provider collaboration and satisfaction on the other. Monitoring and evaluation of these facets need to be an integral part of any safe motherhood programme, not only to assess progress, but also to use this information for subsequent planning and implementation cycles of national programmes. Lessons learned from ten years' implementation of Safe Motherhood programmes indicate that process and outcome indicators are more feasible for short-term evaluation purposes than impact indicators, such as maternal mortality reduction. The former are described in this paper with relevant country examples. This is the third, and last, article in a series on quality of care in reproductive health programmes. The first (Kwast 1998a) contains an overview of concepts, assessments, barriers and improvements of quality of care. The second (Kwast 1998b) addresses education issues for quality improvement.

  20. Transport, acceptance, storage and handling of the itens of nuclear power plants

    International Nuclear Information System (INIS)

    1989-01-01

    The norm aiming to establish the requirements applied to workers or organizations which participate of the activities of transport, acceptance, storage and handling of important itens for safety of nuclear power plants, is presented. The established requirements treat of protection and control necessary to assure that the quality of important itens for safety be it preserved from the end of fabrication until their incorporation to nuclear power plant. (M.C.K.) [pt

  1. Patients’ handling of a standardized medication plan: a pilot study and method development

    Directory of Open Access Journals (Sweden)

    Botermann L

    2016-04-01

    Full Text Available Lea Botermann,1,2 Katrin Krueger,1 Christiane Eickhoff,1 Charlotte Kloft,2 Martin Schulz1–31Department of Medicine, ABDA – Federal Union of German Associations of Pharmacists, Berlin, 2Department of Clinical Pharmacy and Biochemistry, Institute of Pharmacy, Freie Universitaet Berlin, Berlin, 3Department of Pharmacology, Goethe-University Frankfurt, Frankfurt am Main, GermanyPurpose: The Action Plan for Medication Safety by the German Federal Ministry of Health introduced a standardized medication plan (MP, a printable document for the patient. The practical handling needs to be tested before the nationwide implementation in Germany. Therefore, the aims of our study were 1 to develop an instrument to evaluate the usage of the standardized MP, 2 to assess if patients can locate, and 3 understand important information. Moreover, we explored patients’ opinion and suggestions regarding the standardized MP template.Patients and methods: We conducted a cross-sectional study to evaluate the practical handling of the standardized MP. We interviewed 40 adult patients in seven community pharmacies in Germany, who took at least five medicines regularly and gave their written informed consent. The interview consisted of questions regarding finding and understanding information provided on a mock-up MP, patients’ opinion and the execution of the information on the MP by filling pill boxes. We eventually developed a new evaluation method to quantify the practical handling of the MP by rating the pill boxes filled by the patients.Results: Overall, the participants rated the MP positively. Thirty-nine (98% participants found important information on a mock-up standardized MP. Patients were questioned to identify if they understood information on medical intake as it relates to meals. In particular, they were questioned about medicine intake “1 hour before a meal”, which 98% (n=39 interpreted correctly, and “during a meal”, which 100% (n=40

  2. Quality Risk Evaluation of the Food Supply Chain Using a Fuzzy Comprehensive Evaluation Model and Failure Mode, Effects, and Criticality Analysis

    Directory of Open Access Journals (Sweden)

    Libiao Bai

    2018-01-01

    Full Text Available Evaluating the quality risk level in the food supply chain can reduce quality information asymmetry and food quality incidents and promote nationally integrated regulations for food quality. In order to evaluate it, a quality risk evaluation indicator system for the food supply chain is constructed based on an extensive literature review in this paper. Furthermore, a mathematical model based on the fuzzy comprehensive evaluation model (FCEM and failure mode, effects, and criticality analysis (FMECA for evaluating the quality risk level in the food supply chain is developed. A computational experiment aimed at verifying the effectiveness and feasibility of this proposed model is conducted on the basis of a questionnaire survey. The results suggest that this model can be used as a general guideline to assess the quality risk level in the food supply chain and achieve the most important objective of providing a reference for the public and private sectors when making decisions on food quality management.

  3. Internal quality control of PCR-based genotyping methods in research studies and patient diagnostics

    DEFF Research Database (Denmark)

    Bladbjerg, Else-Marie; Gram, Jørgen; Jespersen, Jørgen

    2002-01-01

    Genetic analyses are increasingly integrated in the clinical laboratory, and internal quality control programmes are needed. We have focused on quality control aspects of selected polymorphism analyses used in thrombosis research. DNA was isolated from EDTA-blood (n = 500) by ammonium acetate....... Control of data handling revealed 0.1% reading mistakes and 0.5% entry mistakes. Based on our experiences we propose an internal quality control programme for widely used PCR-based haemostasis polymorphism analyses.......-isolation (pre-analytical factors), DNA-amplification, digestion with restriction enzymes, electrophoresis (analytical factors), result reading and entry into a database (post-analytical factors). Furthermore, we evaluated a procedure for result confirmation. Isolated DNA was of good quality (42 microg/ml blood...

  4. Exploring the relationship between costs and quality. Does the joint evaluation of costs and quality alter the rankings of Danish hospital departments?

    DEFF Research Database (Denmark)

    Hvenegaard, Anne; Nielsen Arendt, Jacob; Street, Andrew

    2011-01-01

    vascular departments, we estimate fixed effect models for costs (linear) and quality (logistic). We consider two quality measures; mortality and wound complications. To assess whether the joint evaluation of costs and quality affects the ranking of departments, we construct joint confidence regions......OBJECTIVE: The purpose is to evaluate the relationship between costs and quality and to assess whether the joint evaluation of costs and quality affects the ranking of hospital departments relative to comparison based on costs alone. METHODS: Using patient level data for 3,754 patients in six...... for each pair of departmental effects for costs and quality using a bootstrap method and rank departments according to their cost-effectiveness ratio. The findings are used to evaluate a theory of a U-shaped cost/quality relationship. RESULTS: The association between cost and quality differs depending...

  5. Quality assurance and the sub-contract interface: co-operative evaluations

    International Nuclear Information System (INIS)

    Churchill, G.F.; Rippon, D.J.

    1976-01-01

    A common feature of all contemporary Quality Assurance Standards is the requirement for organisations, when carrying out purchasing activities, to select their suppliers on the basis of either a proven record or demonstrated quality capability. In particular the C.E.G.B. Standard QA42-1 Quality Assurance Programme, which the C.E.G.B. will apply to their future major projects, requires purchasers to establish supplier selection and assessment procedures using one or other of the following methods: (a) a previous continuous record of supplying identical or equivalent material to a satisfactory standard; or (b) an evaluation of the sub-contractor's quality assurance system to determine his ability to satisfy the procurement requirements. Co-operative evaluations, where there are several suppliers, are discussed. (author)

  6. ATA diagnostic data handling system: an overview

    International Nuclear Information System (INIS)

    Chambers, F.W.; Kallman, J.; McDonald, J.; Slominski, M.

    1984-01-01

    The functions to be performed by the ATA diagnostic data handling system are discussed. The capabilities of the present data acquisition system (System 0) are presented. The goals for the next generation acquisition system (System 1), currently under design, are discussed. Facilities on the Octopus system for data handling are reviewed. Finally, we discuss what has been learned about diagnostics and computer based data handling during the past year

  7. Consumer evaluation of fish quality as basis for fish market segmentation

    DEFF Research Database (Denmark)

    Verbeke, Wim; Vermeir, Iris; Brunsø, Karen

    2007-01-01

    evaluation: personal relevance attached to fish quality and self-confidence in fish quality evaluation, which allow segmenting the market in four fish consumer segments. The segments are typified as Uninvolved, Uncertain, Self-confident and Connoisseurs, and have distinctive behavioural, attitudinal......This paper focuses on consumer evaluation of fish quality and its association with fish consumption, risk and benefit beliefs and information processing variables. Cross-sectional data were collected from a sample of 429 consumers in March 2003 in Belgium. Two dimensions shape fish quality...... and socio-demographic profiles. The Uninvolved are mainly young males, have the lowest fish consumption level, weakest belief in health benefits from eating fish, and lowest interest in both search and credence information cues. Uncertain fish consumers are mainly females, with a tendency of lower education...

  8. Classification and Quality Evaluation of Tobacco Leaves Based on Image Processing and Fuzzy Comprehensive Evaluation

    Science.gov (United States)

    Zhang, Fan; Zhang, Xinhong

    2011-01-01

    Most of classification, quality evaluation or grading of the flue-cured tobacco leaves are manually operated, which relies on the judgmental experience of experts, and inevitably limited by personal, physical and environmental factors. The classification and the quality evaluation are therefore subjective and experientially based. In this paper, an automatic classification method of tobacco leaves based on the digital image processing and the fuzzy sets theory is presented. A grading system based on image processing techniques was developed for automatically inspecting and grading flue-cured tobacco leaves. This system uses machine vision for the extraction and analysis of color, size, shape and surface texture. Fuzzy comprehensive evaluation provides a high level of confidence in decision making based on the fuzzy logic. The neural network is used to estimate and forecast the membership function of the features of tobacco leaves in the fuzzy sets. The experimental results of the two-level fuzzy comprehensive evaluation (FCE) show that the accuracy rate of classification is about 94% for the trained tobacco leaves, and the accuracy rate of the non-trained tobacco leaves is about 72%. We believe that the fuzzy comprehensive evaluation is a viable way for the automatic classification and quality evaluation of the tobacco leaves. PMID:22163744

  9. Automated speech quality monitoring tool based on perceptual evaluation

    OpenAIRE

    Vozňák, Miroslav; Rozhon, Jan

    2010-01-01

    The paper deals with a speech quality monitoring tool which we have developed in accordance with PESQ (Perceptual Evaluation of Speech Quality) and is automatically running and calculating the MOS (Mean Opinion Score). Results are stored into database and used in a research project investigating how meteorological conditions influence the speech quality in a GSM network. The meteorological station, which is located in our university campus provides information about a temperature,...

  10. QUALITY EVALUATION OF THE TPP POWER GENERATING UNITS WEAR RECONDITIONING

    Directory of Open Access Journals (Sweden)

    E. M. Farhadzadeh

    2016-01-01

    Full Text Available Reconditioning of the power generating unit worn equipment and devices is conducted during the scheduled repair period. Quality of wear reconditioning is evaluated by technical state and repair work implementation. Quality of the repair work execution characterizes logistical activities of the power station and the repair services and is rated by a five-grade scale. There are three technical conditions: adequate, subject to reservations, falling short of the technical standard documentation requirements. In practical work these constraints give place to essential ambiguity of the decision. Further to regulating techniques by way of informational support, the authors propose conducting the wear-reconditioning quality evaluation (repair quality accordingly the technical-and-economic indexes pattern of change. The paper recommends applying similarly the fivegrade system in evaluating the power generating unit technical state and distinguishes intolerable, dissatisfactory, fair, good and model estimates. The study demonstrates the assessment criteria dependence on the character of reliability and economical efficiency of performance variation after the repair with increase or decrease of the technical-and-economic indexes in reference to their mean, minimum and maximum values before the repair. The cases ascribed to intolerable quality of the wear reconditioning are those with one or more technical-and-economic indexes that not only failed to improve their values but deteriorated, and at that they became the worst amongst observable values. The model quality estimate of the wear reconditioning is allotted under condition that the power unit technical-and-economic index valuations after the repair not merely improved but also exceeded the best among those under observation. The developed method and algorithm for quality evaluation of the scheduled repair implementation contribute to practical realization of the independent monitoring. This monitoring

  11. Quality evaluation of the nuclear fuel manufactured in Romania before 1990

    International Nuclear Information System (INIS)

    Budan, O.; Galeriu, C.A.; Pascu, A.; Bailescu, A.; Andrei, G.

    1997-01-01

    Nuclear fuel fabricated in Romania before June 1990 was stored and was not licensed for the use in reactor. A preliminary appraisal performed by AECL and Zircatec experts in 1990, considered this fuel as being of suspect quality. Taking into consideration that Nuclear Fuel Plant was qualified to produce CANDU-6 fuel, only after 1990, RENEL-GEN authorized FCN to evaluate the actual quality of the stock fuel, in 1996. A documented evaluation program was developed and implemented. Stock production of each year was considered as one fuel bundle lot. Quality verification was done on statistical basis. Random sampling was applied, with the condition that each production week was represented in the sample. The results show that the fuel quality is not acceptable for in-reactor use. Recovery solutions for the stock fuel were established and already applied. An independent review of the program, results and recovery solutions, made by AECL confirmed the consistency of the work performed by FCN for stock fuel quality evaluation. (author)

  12. Containment system of contamination in irradiated materials handling laboratories

    International Nuclear Information System (INIS)

    Lobao, A.S.T.; Araujo, J.A. de; Camilo, R.L.

    1988-01-01

    A study to prevent radiactivity release in lab scale is presented. As a basis for the design all the limits established by the IAEA for ventilation systems were observed. An evaluation of the different parameters involved in the design have been made, resulting in the specification of the working areas, ducts and filtering systems in order to get the best conditions for the safe handling of irradiated materials. (author) [pt

  13. Quality of dementia diagnostic evaluation for ethnic minority patients: a nationwide study

    DEFF Research Database (Denmark)

    Nielsen, T Rune; Andersen, Birgitte Bo; Kastrup, Marianne

    2011-01-01

    Background/Aims: Diagnostic evaluation of dementia for ethnic minority patients may be challenging. This study aimed to evaluate the quality of diagnostic evaluation of dementia for patients from ethnic minorities in Denmark. Methods: The Danish national hospital registers were used to identify p......: There are significant ethnic disparities in the quality of diagnostic evaluations and outcome of dementia in the secondary healthcare sector....

  14. Automation of 3D micro object handling process

    DEFF Research Database (Denmark)

    Gegeckaite, Asta; Hansen, Hans Nørgaard

    2007-01-01

    Most of the micro objects in industrial production are handled with manual labour or in semiautomatic stations. Manual labour usually makes handling and assembly operations highly flexible, but slow, relatively imprecise and expensive. Handling of 3D micro objects poses special challenges due to ...

  15. Handling and safety enhancement of race cars using active aerodynamic systems

    Science.gov (United States)

    Diba, Fereydoon; Barari, Ahmad; Esmailzadeh, Ebrahim

    2014-09-01

    A methodology is presented in this work that employs the active inverted wings to enhance the road holding by increasing the downward force on the tyres. In the proposed active system, the angles of attack of the vehicle's wings are adjusted by using a real-time controller to increase the road holding and hence improve the vehicle handling. The handling of the race car and safety of the driver are two important concerns in the design of race cars. The handling of a vehicle depends on the dynamic capabilities of the vehicle and also the pneumatic tyres' limitations. The vehicle side-slip angle, as a measure of the vehicle dynamic safety, should be narrowed into an acceptable range. This paper demonstrates that active inverted wings can provide noteworthy dynamic capabilities and enhance the safety features of race cars. Detailed analytical study and formulations of the race car nonlinear model with the airfoils are presented. Computer simulations are carried out to evaluate the performance of the proposed active aerodynamic system.

  16. Influence of low stress handling during clinical visit on physiological and behavioural indicators in adult dogs: a preliminary study

    Directory of Open Access Journals (Sweden)

    Bruno Scalia

    2017-12-01

    Full Text Available Low stress handling techniques or “Fear Free principles” in veterinary clinics are becoming an important research area aimed at improving small animal welfare, considering that the majority of dogs who undergo clinical examinations exhibit fear or anxiety signs. Objective of this study was to compare a number of physiological and behavioural indicators using low stress handling (LSH and traditional (TT techniques in order to assess whether the LSH approach had a positive impact on the dog’s welfare. Eight adult dogs were filmed while undergoing both LSH and TT visits (separated by a distance of seven weeks. The same usual sequence of events was followed for both visits (e. g. muzzle wearing, heart and lungs stethoscope examination, etc. except that 1 during the LSH visit, the dog was free to explore the environment (while receiving treats and play for five minutes before and after the visit 2 throughout the medical examination the veterinarians’ attitude and handling techniques were always aimed at preventing stress and guaranteeing the best physical support possible. The videos were then evaluated for the number of fear and stress signs the subjects showed. The examined physiological variables were respiration (breath/min, heart rate (HR and rectal temperature (RT. Physiological variables were analysed by t-Test for paired data while frequency of behavioural fear indicators by Wilcoxon signed-rank test. Rectal temperature was within range in both groups but significantly higher (P<0.05 during LSH visit, while low head, lip licks and whale eye behaviours were significantly higher (P<0.05 during TT visit. These results suggest that low stress handling decreases frequency of some fear-related behaviours and could improve the quality of human-dog interactions. Future research that aims to replicate and further investigate these results in a large canine population is required.

  17. Food handling in the household environment as a vulnerability factor to foodborne diseases

    Directory of Open Access Journals (Sweden)

    Carla Rosane Paz Arruda Teo

    2016-06-01

    Full Text Available Introduction: the concept of food security and nutrition is based on the regular and sufficient access to food of adequate quality and it implies food safety as one of its dimensions. Objective: to analyze the sanitary and hygienic conditions of food handling in households in Chapecó (SC, Brazil. Materials and Methods: descriptive study with 138 households selected by systematic sampling to a 5% significance level and a 4% acceptable error. We applied a questionnaire to the person who was the responsible for food handling in each household. We used descriptive and inferential statistics and we interpreted the data according to health vulnerability framework. Results: we highlight that 50.7% (n=70 reported to just wash vegetables with water, 71% (n=98 reported to wash cutting boards with detergent and cold water, 33, 3% (n=46 reported the use of raw eggs. There was no association between the source of water supply and sanitary failures observed. Conclusions: safe food handling procedures are not adopted in a reasonable proportion of households, which may explain the vulnerability to foodborne diseases in these environments.

  18. WWER NPPs fuel handling machine control system

    International Nuclear Information System (INIS)

    Mini, G.; Rossi, G.; Barabino, M.; Casalini, M.

    2001-01-01

    In order to increase the safety level of the fuel handling machine on WWER NPPs, Ansaldo Nucleare was asked to design and supply a new Control System. Two FHM Control System units have been already supplied for Temelin NPP and others supplies are in process for the Atommash company, which has in charge the supply of FHMs for NPPs located in Russia, Ukraine and China. The Fuel Handling Machine (FHM) Control System is an integrated system capable of a complete management of nuclear fuel assemblies. The computer-based system takes into account all the operational safety interlocks so that it is able to avoid incorrect and dangerous manoeuvres in the case of operator error. Control system design criteria, hardware and software architecture, and quality assurance control, are in accordance with the most recent international requirements and standards, and in particular for electromagnetic disturbance immunity demands and seismic compatibility. The hardware architecture of the control system is based on ABB INFI 90 system. The microprocessor-based ABB INFI 90 system incorporates and improves upon many of the time proven control capabilities of Bailey Network 90, validated over 14,000 installations world-wide. The control system complies all the former designed sensors and devices of the machine and markedly the angular position measurement sensors named 'selsyn' of Russian design. Nevertheless it is fully compatible with all the most recent sensors and devices currently available on the market (for ex. Multiturn absolute encoders). All control logic components were developed using standard INFI 90 Engineering Work Station, interconnecting blocks extracted from an extensive SAMA library by using a graphical approach (CAD) and allowing an easier intelligibility, more flexibility and updated and coherent documentation. The data acquisition system and the Man Machine Interface are implemented by ABB in co-operation with Ansaldo. The flexible and powerful software structure

  19. VVER NPPs fuel handling machine control system

    International Nuclear Information System (INIS)

    Mini, G.; Rossi, G.; Barabino, M.; Casalini, M.

    2002-01-01

    In order to increase the safety level of the fuel handling machine on WWER NPPs, Ansaldo Nucleare was asked to design and supply a new Control System. Two Fuel Handling Machine (FHM) Control System units have been already supplied for Temelin NPP and others supply are in process for the Atommash company, which has in charge the supply of FHMs for NPPs located in Russia, Ukraine and China.The computer-based system takes into account all the operational safety interlocks so that it is able to avoid incorrect and dangerous manoeuvres in the case of operator error. Control system design criteria, hardware and software architecture, and quality assurance control, are in accordance with the most recent international requirements and standards, and in particular for electromagnetic disturbance immunity demands and seismic compatibility. The hardware architecture of the control system is based on ABB INFI 90 system. The microprocessor-based ABB INFI 90 system incorporates and improves upon many of the time proven control capabilities of Bailey Network 90, validated over 14,000 installations world-wide.The control system complies all the former designed sensors and devices of the machine and markedly the angular position measurement sensors named 'selsyn' of Russian design. Nevertheless it is fully compatible with all the most recent sensors and devices currently available on the market (for ex. Multiturn absolute encoders).All control logic were developed using standard INFI 90 Engineering Work Station, interconnecting blocks extracted from an extensive SAMA library by using a graphical approach (CAD) and allowing and easier intelligibility, more flexibility and updated and coherent documentation. The data acquisition system and the Man Machine Interface are implemented by ABB in co-operation with Ansaldo. The flexible and powerful software structure of 1090 Work-stations (APMS - Advanced Plant Monitoring System, or Tenore NT) has been successfully used to interface the

  20. Handling encapsulated spent fuel in a geologic repository environment

    International Nuclear Information System (INIS)

    Ballou, L.B.

    1983-02-01

    In support of the Spent Fuel Test-Climate at the U.S. Department of Energy's Nevada Test Site, a spent-fuel canister handling system has been designed, deployed, and operated successfully during the past five years. This system transports encapsulated commercial spent-fuel assemblies between the packaging facility and the test site (approx. 100 km), transfers the canisters 420 m vertically to and from a geologic storage drift, and emplaces or retrieves the canisters from the storage holes in the floor of the drift. The spent-fuel canisters are maintained in a fully shielded configuration at all times during the handling cycle, permitting manned access at any time for response to any abnormal conditions. All normal operations are conducted by remote control, thus assuring as low as reasonably achievable exposures to operators; specifically, we have had no measurable exposure during 30 canister transfer operations. While not intended to be prototypical of repository handling operations, the system embodies a number of concepts, now demonstrated to be safe, reliable, and economical, which may be very useful in evaluating full-scale repository handling alternatives in the future. Among the potentially significant concepts are: Use of an integral shielding plug to minimize radiation streaming at all transfer interfaces. Hydraulically actuated transfer cask jacking and rotation features to reduce excavation headroom requirements. Use of a dedicated small diameter (0.5 m) drilled shaft for transfer between the surface and repository workings. A wire-line hoisting system with positive emergency braking device which travels with the load. Remotely activated grapples - three used in the system - which are insensitive to load orientation. Rail-mounted underground transfer vehicle operated with no personnel underground

  1. Surface Water Quality Evaluation Based on a Game Theory-Based Cloud Model

    Directory of Open Access Journals (Sweden)

    Bing Yang

    2018-04-01

    Full Text Available Water quality evaluation is an essential measure to analyze water quality. However, excessive randomness and fuzziness affect the process of evaluation, thus reducing the accuracy of evaluation. Therefore, this study proposed a cloud model for evaluating the water quality to alleviate this problem. Analytic hierarchy process and entropy theory were used to calculate the subjective weight and objective weight, respectively, and then they were coupled as a combination weight (CW via game theory. The proposed game theory-based cloud model (GCM was then applied to the Qixinggang section of the Beijiang River. The results show that the CW ranks fecal coliform as the most important factor, followed by total nitrogen and total phosphorus, while biochemical oxygen demand and fluoride were considered least important. There were 19 months (31.67% at grade I, 39 months (65.00% at grade II, and one month at grade IV and grade V during 2010–2014. A total of 52 months (86.6% of GCM were identical to the comprehensive evaluation result (CER. The obtained water quality grades of GCM are close to the grades of the analytic hierarchy process weight (AHPW due to the weight coefficient of AHPW set to 0.7487. Generally, one or two grade gaps exist among the results of the three groups of weights, suggesting that the index weight is not particularly sensitive to the cloud model. The evaluated accuracy of water quality can be improved by modifying the quantitative boundaries. This study could provide a reference for water quality evaluation, prevention, and improvement of water quality assessment and other applications.

  2. Towards web documents quality assessment for digital humanities scholars

    NARCIS (Netherlands)

    Ceolin, D.; Noordegraaf, Julia; Aroyo, L.M.; van Son, C.M.; Nejdl, Wolfgang; Hall, Wendy; Parigi, Paolo; Staab, Steffen

    2016-01-01

    We present a framework for assessing the quality of Web documents, and a baseline of three quality dimensions: trustworthiness, objectivity and basic scholarly quality. Assessing Web document quality is a "deep data" problem necessitating approaches to handle both data size and complexity.

  3. Review of models used for determining consequences of UF6 release: Development of model evaluation criteria. Volume 1

    International Nuclear Information System (INIS)

    Nair, S.K.; Chambers, D.B.; Park, S.H.; Hoffman, F.O.

    1997-11-01

    The objective of this study is to examine the usefulness and effectiveness of currently existing models that simulate the release of uranium hexafluoride from UF 6 -handling facilities, subsequent reactions of UF 6 with atmospheric moisture, and the dispersion of UF 6 and reaction products in the atmosphere. The study evaluates screening-level and detailed public-domain models that were specifically developed for UF 6 and models that were originally developed for the treatment of dense gases but are applicable to UF 6 release, reaction, and dispersion. The model evaluation process is divided into three specific tasks: model-component evaluation; applicability evaluation; and user interface and quality assurance and quality control (QA/QC) evaluation. Within the model-component evaluation process, a model's treatment of source term, thermodynamics, and atmospheric dispersion are considered and model predictions are compared with actual observations. Within the applicability evaluation process, a model's applicability to Integrated Safety Analysis, Emergency Response Planning, and Post-Accident Analysis, and to site-specific considerations are assessed. Finally, within the user interface and QA/QC evaluation process, a model's user-friendliness, presence and clarity of documentation, ease of use, etc. are assessed, along with its handling of QA/QC. This document presents the complete methodology used in the evaluation process

  4. Quality assurance/quality control summary report on phase 2 of the Clinch River remedial investigation at the Oak Ridge Reservation, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Holladay, S.K.; Anderson, H.M.; Benson, S.B.; Bevelhimer, M.S.; Brandt, C.C.; Chavannes, C.M.; Cook, R.B.; Evans, D.A.; Ford, C.J.; Harris, R.A.; Horwedel, B.M.; Jackson, B.L.

    1996-12-01

    Quality assurance (QA) objectives for Phase 2 were that (1) scientific data generated would withstand scientific and legal scrutiny; (2) data would be gathered using appropriate procedures for sample collection, sample handling and security, chain of custody, laboratory analyses, and data reporting; (3) data would be of known precision and accuracy; and (4) data would meet data quality objectives defined in the Phase 2 Sampling and Analysis Plan. A review of the QA systems and quality control (QC) data associated with the Phase 2 investigation is presented to evaluate whether the data were of sufficient quality to satisfy Phase 2 objectives. The data quality indicators of precision, accuracy, representativeness, comparability, completeness, and sensitivity were evaluated to determine any limitations associated with the data. Data were flagged with qualifiers that were associated with appropriate reason codes and documentation relating the qualifiers to the reviewer of the data. These qualifiers were then consolidated into an overall final qualifier to represent the quality of the data to the end user. In summary, reproducible, precise, and accurate measurements consistent with CRRI objectives and the limitations of the sampling and analytical procedures used were obtained for the data collected in support of the Phase 2 Remedial Investigation.

  5. Quality assurance/quality control summary report on phase 2 of the Clinch River remedial investigation at the Oak Ridge Reservation, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    Holladay, S.K.; Anderson, H.M.; Benson, S.B.; Bevelhimer, M.S.; Brandt, C.C.; Chavannes, C.M.; Cook, R.B.; Evans, D.A.; Ford, C.J.; Harris, R.A.; Horwedel, B.M.; Jackson, B.L.

    1996-12-01

    Quality assurance (QA) objectives for Phase 2 were that (1) scientific data generated would withstand scientific and legal scrutiny; (2) data would be gathered using appropriate procedures for sample collection, sample handling and security, chain of custody, laboratory analyses, and data reporting; (3) data would be of known precision and accuracy; and (4) data would meet data quality objectives defined in the Phase 2 Sampling and Analysis Plan. A review of the QA systems and quality control (QC) data associated with the Phase 2 investigation is presented to evaluate whether the data were of sufficient quality to satisfy Phase 2 objectives. The data quality indicators of precision, accuracy, representativeness, comparability, completeness, and sensitivity were evaluated to determine any limitations associated with the data. Data were flagged with qualifiers that were associated with appropriate reason codes and documentation relating the qualifiers to the reviewer of the data. These qualifiers were then consolidated into an overall final qualifier to represent the quality of the data to the end user. In summary, reproducible, precise, and accurate measurements consistent with CRRI objectives and the limitations of the sampling and analytical procedures used were obtained for the data collected in support of the Phase 2 Remedial Investigation

  6. Origin discrimination and quality evaluation of Gastrodiae rhizoma ...

    African Journals Online (AJOL)

    quality control and origin discrimination of Gastrodiae rhizoma. Methods: Twelve .... Similarity. Evaluation. System for. Chromatographic Fingerprint of Traditional. Chinese Medicine ..... chromatography with tandem quadrupole time-of-flight.

  7. Sequence trajectory generation for garment handling systems

    OpenAIRE

    Liu, Honghai; Lin, Hua

    2008-01-01

    This paper presents a novel generic approach to the planning strategy of garment handling systems. An assumption is proposed to separate the components of such systems into a component for intelligent gripper techniques and a component for handling planning strategies. Researchers can concentrate on one of the two components first, then merge the two problems together. An algorithm is addressed to generate the trajectory position and a clothes handling sequence of clothes partitions, which ar...

  8. Evaluation of Sample Handling Effects on Serum Vitamin E and Cholesterol Concentrations in Alpacas

    Directory of Open Access Journals (Sweden)

    Andrea S. Lear

    2014-01-01

    Full Text Available Clinical cases of vitamin E deficiencies have been diagnosed in camelids and may indicate that these species are more sensitive to inadequate vitamin E in hay-based diets compared to other ruminant and equine species. In bovine, cholesterol has been reported to affect vitamin E concentrations. In order to evaluate vitamin E deficiencies in camelids, the effects of collection and storage of the blood samples prior to processing were necessary. Reports vary as to factors affecting vitamin E and cholesterol in blood samples, and diagnostic laboratories vary in instructions regarding sample handling. Blood was collected from healthy alpacas and processed under conditions including exposure to fluorescent light, serum and red blood cell contact, tube stopper contact, temperature, and hemolysis. Serum vitamin E and cholesterol concentrations were then measured. Statistical analyses found that the vitamin E concentrations decreased with prolonged contact with the tube stopper and with increasing hemolysis. Vitamin E concentration variations were seen with other factors but were not significant. Time prior to serum separation and individual animal variation was found to alter cholesterol concentrations within the sample, yet this finding was clinically unremarkable. No correlation was seen between vitamin E and cholesterol concentration, possibly due to lack of variation of cholesterol.

  9. Quality evaluation in health care services based on customer-provider relationships.

    Science.gov (United States)

    Eiriz, Vasco; Figueiredo, José António

    2005-01-01

    To develop a framework for evaluating the quality of Portuguese health care organisations based on the relationship between customers and providers, to define key variables related to the quality of health care services based on a review of the available literature, and to establish a conceptual framework in order to test the framework and variables empirically. Systematic review of the literature. Health care services quality should not be evaluated exclusively by customers. Given the complexity, ambiguity and heterogeneity of health care services, the authors develop a framework for health care evaluation based on the relationship between customers (patients, their relatives and citizens) and providers (managers, doctors, other technical staff and non-technical staff), and considering four quality items (customer service orientation, financial performance, logistical functionality and level of staff competence). This article identifies important changes in the Portuguese health care industry, such as the ownership of health care providers. At the same time, customers are changing their attitudes towards health care, becoming much more concerned and demanding of health services. These changes are forcing Portuguese private and public health care organisations to develop more marketing-oriented services. This article recognises the importance of quality evaluation of health care services as a means of increasing customer satisfaction and organisational efficiency, and develops a framework for health care evaluation based on the relationship between customers and providers.

  10. Health-educator performance evaluation for quality teaching ...

    African Journals Online (AJOL)

    The aim of this study was to investigate the efficacy of health educator performance evaluation procedures using the Integrated Quality Management System. This quantitative study used questionnaires to collect data from three hundred and thirty eight respondents selected through a convenient sampling procedure.

  11. Quality data systems

    International Nuclear Information System (INIS)

    Bergman, J.E.; Patterson, R.G.

    1976-01-01

    General Electric's Nuclear Fuel Department data system strategy of multifunctional system integration and specific applications of data systems for the Quality Assurance Programme is detailed. Descriptions of two manufacturing control systems and their function in satisfying quality data requirements are included. The timesharing quality data system developed for processing laboratory, traceability and material release data in the Fuel Manufacturing Operation is described. In addition, specific references are made to those areas where significant time reductions have been realized through the utilization of mechanized data-handling systems. (author)

  12. [Development of an evaluation instrument for service quality in nursing homes].

    Science.gov (United States)

    Lee, Jia; Ji, Eun Sun

    2011-08-01

    The purposes of this study were to identify the factors influencing service quality in nursing homes, and to develop an evaluation instrument for service quality. A three-phase process was employed for the study. 1) The important factors to evaluate the service quality in nursing homes were identified through a literature review, panel discussion and focus group interview, 2) the evaluation instrument was developed, and 3) validity and reliability of the study instrument were tested by factor analysis, Pearson correlation coefficient, Cronbach's α and Cohen's Kappa. Factor analysis showed that the factors influencing service quality in nursing homes were healthcare, diet/assistance, therapy, environment and staff. To improve objectivity of the instrument, quantitative as well as qualitative evaluation approaches were adopted. The study instrument was developed with 30 items and showed acceptable construct validity. The criterion-related validity was a Pearson correlation coefficient of .85 in 151 care facilities. The internal consistency was Cronbach's α=.95. The instrument has acceptable validity and a high degree of reliability. Staff in nursing homes can continuously improve and manage their services using the results of the evaluation instrument.

  13. Chemical markers for the quality control of herbal medicines: an overview

    Directory of Open Access Journals (Sweden)

    Lung Cheng Chuen

    2008-06-01

    Full Text Available Abstract Selection of chemical markers is crucial for the quality control of herbal medicines, including authentication of genuine species, harvesting the best quality raw materials, evaluation of post-harvesting handling, assessment of intermediates and finished products, and detection of harmful or toxic ingredients. Ideal chemical markers should be the therapeutic components of herbal medicines. However, for most herbal medicines, the therapeutic components have not been fully elucidated or easily monitored. Bioactive, characteristic, main, synergistic, correlative, toxic and general components may be selected. This article reviews the effective use of chemical markers in the quality control of herbal medicines including the selection criteria considering the roles and physicochemical factors which may affect the effective use of chemical markers.

  14. Quality at the source (QATS) system design under six sigma methodology

    Energy Technology Data Exchange (ETDEWEB)

    Aguirre, F; Ballasteros, I; Maricalva, J [Emperesa Nacional del Uranio, S.A. (ENUSA), Nuclear Fuel Manufacturing Plant, Juzbado, Salamanca (Spain)

    2000-07-01

    One of the main objectives in the manufacturing of fuel assemblies, is to fulfill the customer expectations with a product that assures its reliability during its stay in the NPP. By mean of the QATS System design under 6-Sigma methodology, all the customer requirements are included in the product specifications and drawings. Product characteristics and process variables are classified and process capability is evaluated. All this information permits to identify CTQ's (Critical to Quality) product characteristics and process variables, and to define a quality system (QATS) based in the process and on-line characteristics control handled by the manufacturing workers. At the end, this system ensures a continuous product quality improvement, and a strong commitment with the customer requirements. (author)

  15. Quality at the source (QATS) system design under six sigma methodology

    International Nuclear Information System (INIS)

    Aguirre, F.; Ballasteros, I.; Maricalva, J.

    2000-01-01

    One of the main objectives in the manufacturing of fuel assemblies, is to fulfill the customer expectations with a product that assures its reliability during its stay in the NPP. By mean of the QATS System design under 6-Sigma methodology, all the customer requirements are included in the product specifications and drawings. Product characteristics and process variables are classified and process capability is evaluated. All this information permits to identify CTQ's (Critical to Quality) product characteristics and process variables, and to define a quality system (QATS) based in the process and on-line characteristics control handled by the manufacturing workers. At the end, this system ensures a continuous product quality improvement, and a strong commitment with the customer requirements. (author)

  16. Remote handling for an ISIS target change

    International Nuclear Information System (INIS)

    Broome, T.A.; Holding, M.

    1989-01-01

    During 1987 two ISIS targets were changed. This document describes the main features of the remote handling aspects of the work. All the work has to be carried out using remote handling techniques. The radiation level measured on the surface of the reflector when the second target had been removed was about 800 mGy/h demonstrating that hands on operations on any part of the target reflector moderator assembly is not practical. The target changes were the first large scale operations in the Target Station Remote Handling Cell and a great deal was learned about both equipment and working practices. Some general principles emerged which are applicable to other active handling tasks on facilities like ISIS and these are discussed below. 8 figs

  17. Remote handling and robotic inspections of Palo Verde reactor vessel internals

    International Nuclear Information System (INIS)

    Ryder, W.

    1998-01-01

    Remote visual examinations and handling evolutions in high radiation field environments have required the use of radiation tolerant video systems. These systems involve significant expense and potentially require large envelope deployment structures. Recent events at Palo Verde including Upper Guide Structure damage and Reactor Vessel In-Service Inspections have provided opportunities for research, design and utilization of alternative approaches. Most significant of these, utilization of CCD modules with high magnification capabilities, have produced higher quality viewing, reduced maintenance expenditures, and rapid deployment intervals. (orig.) [de

  18. Materials Handling. Module SH-01. Safety and Health.

    Science.gov (United States)

    Center for Occupational Research and Development, Inc., Waco, TX.

    This student module on materials handling is one of 50 modules concerned with job safety and health. It presents the procedures for safe materials handling. Discussed are manual handling methods (lifting and carrying by hand) and mechanical lifting (lifting by powered trucks, cranes or conveyors). Following the introduction, 15 objectives (each…

  19. Enclosure for handling high activity materials abstract

    International Nuclear Information System (INIS)

    Jimeno de Osso, F.; Dominguez Rodriguez, G.; Cruz Castillo, F. de la; Rodriguez Esteban, A.

    1977-01-01

    One of the most important problems that are met at the laboratories producing and handling radioisotopes is that of designing, building and operating enclosures suitable for the safe handling of active substances. With that purpose in mind, an enclosure has been designed and built for handling moderately high activities under a shielding made of 150 mm thick lead. A description is given of those aspects that may be of interest to people working in this field. (author) [es

  20. Quality assurance and evaluation system in japanese higher education

    Directory of Open Access Journals (Sweden)

    Ana Mami Yamaguchi

    2016-03-01

    Full Text Available Abstract In this paper we aim to contribute to the debate over accountability and assessment of higher education (HE by introducing the Japanese system. We first discuss the circumstances and issues surrounding Japanese HE and then examine the historical development of the quality assurance and evaluation system. Since the 1990s, with the implementation of policies that focused on liberalization, deregulation and increased institutional autonomy, the role of the government has shifted from setting strict regulations and quality standards to organizing an evaluation system for assessing the learning outcomes and improving accountability of the HE institutions. Finally, we suggest how Japan may take hints from Brazil in organizing an evaluation system on a national level that can more efficiently support and assess HE institutions

  1. Concept Evaluation Using the PDSA Cycle for Continuous Quality Improvement.

    Science.gov (United States)

    Laverentz, Delois Meyer; Kumm, Sharon

    As concept-based nursing education gains popularity, there is little literature on how to sustain quality after initiation of the curriculum. Critical appraisal of concepts in a university program revealed varying definitions, attributes, and exemplars resulting in student confusion. The Plan, Do, Study, Act (PDSA) cycle for continuous quality improvement was used for concept evaluation. The goals of the evaluation project were: 1) to develop common definition and attributes for concepts and 2) to develop horizontal and vertical leveling of exemplars to build on prior student learning. The continuous quality improvement process can be used to prevent "concept creep" and ensure internal consistency of concept definitions, attributes, and exemplars.

  2. THE APPLICATION OF MASSING HANDLING THEORY FOR EVALUATION OF THE APPLICATION OF WHARVES AND LOADING FACILITIES IN THE MARITIME PORT

    Directory of Open Access Journals (Sweden)

    Zbigniew Matuszak

    2016-09-01

    Full Text Available This work presents the general characteristics of the port system. It defines sets and functions describing the structure and work of the port. Moreover, it characterizes foundations of the massive handling theory. It provides basic literature information about selected processes and models of the massive handling theory. On the example of a transportation company serving the loading on ships in the port of Szczecin, it shows the loading method. The material loading onto ships was the sodium water glass. There are observation results of operation times comprising the data available to determine parameters of the massive handling theory. Operations covered in the analysis include: the arrival of the ship at the port’s road, waiting for enter the port, passing through the fairway, waiting for loading, loading, determination of the cargo’s weight, preparation of documents and waiting for leaving the port. It presents critical remarks about possibilities of using the data obtained to describe loading cargo on a ship with the use of elements of the massive handling theory.

  3. Development of tritium-handling technique

    International Nuclear Information System (INIS)

    Ohmura, Hiroshi; Hosaka, Akio; Okamoto, Takahumi

    1988-01-01

    The overview of developing activities for tritium-handling techniques in IHI are presented. To establish a fusion power plant, tritium handling is one of the key technologies. Recently in JAERI, conceptual design of FER (Fusion Experimental Reactor) has been carried out, and the FER system requires a processing system for a large amount of tritium. IHI concentrate on investigation of fuel gas purification, isotope separation and storage systems under contract with Toshiba Corporation. Design results of the systems and each components are reviewed. IHI has been developing fundamental handling techniques which are the ZrNi bed for hydrogen isotope storage and isotope separation by laser. The ZrNi bed with a tritium storage capacity of 1000 Ci has been constructed and recovery capability of the hydrogen isotope until 10 -4 Torr {0.013 Pa} was confirmed. In laser isotope separation, the optimum laser wave length has been determined. (author)

  4. Handling of waste in ports

    International Nuclear Information System (INIS)

    Olson, P.H.

    1994-01-01

    The regulations governing the handling of port-generated waste are often national and/or local legislation, whereas the handling of ship-generated waste is governed by the MARPOL Convention in most parts of the world. The handling of waste consists of two main phases -collection and treatment. Waste has to be collected in every port and on board every ship, whereas generally only some wastes are treated and to a certain degree in ports and on board ships. This paper considers the different kinds of waste generated in both ports and on board ships, where and how it is generated, how it could be collected and treated. The two sources are treated together to show how some ship-generated waste may be treated in port installations primarily constructed for the treatment of the port-generated waste, making integrated use of the available treatment facilities. (author)

  5. Implementation of an ergonomics intervention in a Swedish flight baggage handling company—A process evaluation

    Science.gov (United States)

    Mathiassen, Svend Erik; Larsson, Johan; Kwak, Lydia

    2018-01-01

    Objective To conduct a process evaluation of the implementation of an ergonomics training program aimed at increasing the use of loading assist devices in flight baggage handling. Methods Feasibility related to the process items recruitment, reach, context, dose delivered (training time and content); dose received (participants’ engagement); satisfaction with training; intermediate outcomes (skills, confidence and behaviors); and barriers and facilitators of the training intervention were assessed by qualitative and quantitative methods. Results Implementation proved successful regarding dose delivered, dose received and satisfaction. Confidence among participants in the training program in using and talking about devices, observed use of devices among colleagues, and internal feedback on work behavior increased significantly (p<0.01). Main facilitators were self-efficacy, motivation, and perceived utility of training among the trainees. Barriers included lack of peer support, opportunities to observe and practice behaviors, and follow-up activities; as well as staff reduction and job insecurity. Conclusions In identifying important barriers and facilitators for a successful outcome, this study can help supporting the effectiveness of future interventions. Our results suggest that barriers caused by organizational changes may likely be alleviated by recruiting motivated trainees and securing strong organizational support for the implementation. PMID:29513671

  6. Consumer Evaluations of Food Risk Management Quality in Europe

    NARCIS (Netherlands)

    Kleef, van E.; Houghton, J.R.; Krystallis, A.; Pfenning, U.; Rowe, G.; Dijk, van H.; Lans, van der I.A.; Frewer, L.J.

    2007-01-01

    In developing and implementing appropriate food risk management strategies, it is important to understand how consumers evaluate the quality of food risk management practices. The aim of this study is to model the underlying psychological factors influencing consumer evaluations of food risk

  7. Exploratory study of logistics service quality scale based on online shopping malls

    Institute of Scientific and Technical Information of China (English)

    FENG Yi-xiong; ZHENG Bing; TAN Jian-rong

    2007-01-01

    Online shopping has already become the new mode that a lot of customers try to adopt. At the same time, the online shopping could not be successfully completed without logistics service. Logistics service quality (LSQ) has significant impact on revenue and profitability. This paper presents the issue from the perspective of the customer, and explores the initial factors of LSQ based on the online shopping through in-depth interview and the Delphi method. The survey uses a standard 7-point Likert-type scale to measure the LSQ. Empirical research results are shown in detail to confirm seven LSQ dimensions with Chinese characteristics, including timeliness quality, personal contact quality, order quality, order discrepancy handling, order condition and convenience. Statistical analyses of the investigation were conducted to test the reliability and validity of the LSQ evaluation model.

  8. How to Handle Impasses in Bargaining.

    Science.gov (United States)

    Durrant, Robert E.

    Guidelines in an outline format are presented to school board members and administrators on how to handle impasses in bargaining. The following two rules are given: there sometimes may be strikes, but there always will be settlements; and on the way to settlements, there always will be impasses. Suggestions for handling impasses are listed under…

  9. A rule-based fault detection method for air handling units

    Energy Technology Data Exchange (ETDEWEB)

    Schein, J.; Bushby, S. T.; Castro, N. S. [National Institute of Standards and Technology, Gaithersburg, MD (United States); House, J. M. [Iowa Energy Center, Ankeny, IA (United States)

    2006-07-01

    Air handling unit performance assessment rules (APAR) is a fault detection tool that uses a set of expert rules derived from mass and energy balances to detect faults in air handling units (AHUs). Control signals are used to determine the mode of operation of the AHU. A subset of the expert rules which correspond to that mode of operation are then evaluated to determine whether a fault exists. APAR is computationally simple enough that it can be embedded in commercial building automation and control systems and relies only upon the sensor data and control signals that are commonly available in these systems. APAR was tested using data sets collected from a 'hardware-in-the-loop' emulator and from several field sites. APAR was also embedded in commercial AHU controllers and tested in the emulator. (author)

  10. CALiPER Report 20.1: Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2013-11-07

    This report focuses on human-evaluated characteristics, including beam quality, shadow quality, and color quality. Using a questionnaire that included rank-ordering, opinions on 27 of the Report 20 PAR38 lamps were gathered during a demonstration event for members of the local Illuminating Engineering Society (IES) chapter. This was not a rigorous scientific experiment, and the data should not be extrapolated beyond the scope of the demonstration. The results suggest that many of the LED products compared favorably to halogen PAR38 benchmarks in all attributes considered. LED lamps using a single-emitter design were generally preferred for their beam quality and shadow quality, and the IES members' ranking of color quality did not always match the rank according to the color rendering index (CRI).

  11. Methodology for Evaluating Quality and Reusability of Learning Objects

    Science.gov (United States)

    Kurilovas, Eugenijus; Bireniene, Virginija; Serikoviene, Silvija

    2011-01-01

    The aim of the paper is to present the scientific model and several methods for the expert evaluation of quality of learning objects (LOs) paying especial attention to LOs reusability level. The activities of eQNet Quality Network for a European Learning Resource Exchange (LRE) aimed to improve reusability of LOs of European Schoolnet's LRE…

  12. Fish product quality evaluation based on temperature monitoring in ...

    African Journals Online (AJOL)

    As one kind of perishable food, fish product is at risk of suffering various damages during cold chain and temperature is the most important factor to affect the product quality. This research work on frozen tilapia fillet was aimed at evaluating the fish product quality and predict shelf-life through monitoring temperature change ...

  13. Functional Quality Criterion of Rock Handling Mechanization at Open-pit Mines

    Directory of Open Access Journals (Sweden)

    Voronov Yuri

    2017-01-01

    Full Text Available Overburden and mining operations at open-pit mines are performed mainly by powerful shovel-truck systems (STSs. One of the main problems of the STSs is a rather low level of their operating quality, mainly due to unjustified over-trucking. In this article, a functional criterion for assessing the qualify of the STS operation at open-pit mines is formulated, derived and analyzed. We introduce the rationale and general principles for the functional criterion formation, its general form, as well as variations for various STS structures: a mixed truck fleet and a homogeneous shovel fleet, a mixed shove! fleet and a homogeneous truck fleet, mixed truck and shovel fleets. The possibility of assessing the quality of the STS operation is of great importance for identifying the main directions for improving their operational performance and operating quality, optimizing the main performance indicators by the qualify criterion, and. as a result, for possible saving of material and technical resources for open-pit mining. Improvement of the quality of the STS operation also allows increasing the mining safety and decreasing the atmosphere pollution - by means of possible reducing of the number of the operating trucks.

  14. Functional Quality Criterion of Rock Handling Mechanization at Open-pit Mines

    Science.gov (United States)

    Voronov, Yuri; Voronov, Artyoni

    2017-11-01

    Overburden and mining operations at open-pit mines are performed mainly by powerful shovel-truck systems (STSs). One of the main problems of the STSs is a rather low level of their operating quality, mainly due to unjustified over-trucking. In this article, a functional criterion for assessing the qualify of the STS operation at open-pit mines is formulated, derived and analyzed. We introduce the rationale and general principles for the functional criterion formation, its general form, as well as variations for various STS structures: a mixed truck fleet and a homogeneous shovel fleet, a mixed shove! fleet and a homogeneous truck fleet, mixed truck and shovel fleets. The possibility of assessing the quality of the STS operation is of great importance for identifying the main directions for improving their operational performance and operating quality, optimizing the main performance indicators by the qualify criterion, and. as a result, for possible saving of material and technical resources for open-pit mining. Improvement of the quality of the STS operation also allows increasing the mining safety and decreasing the atmosphere pollution - by means of possible reducing of the number of the operating trucks.

  15. WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT

    Energy Technology Data Exchange (ETDEWEB)

    J. D. Bigbee

    2000-06-21

    The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status.

  16. WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT

    International Nuclear Information System (INIS)

    J. D. Bigbee

    2000-01-01

    The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status

  17. Quinone-induced protein handling changes: Implications for major protein handling systems in quinone-mediated toxicity

    International Nuclear Information System (INIS)

    Xiong, Rui; Siegel, David; Ross, David

    2014-01-01

    Para-quinones such as 1,4-Benzoquinone (BQ) and menadione (MD) and ortho-quinones including the oxidation products of catecholamines, are derived from xenobiotics as well as endogenous molecules. The effects of quinones on major protein handling systems in cells; the 20/26S proteasome, the ER stress response, autophagy, chaperone proteins and aggresome formation, have not been investigated in a systematic manner. Both BQ and aminochrome (AC) inhibited proteasomal activity and activated the ER stress response and autophagy in rat dopaminergic N27 cells. AC also induced aggresome formation while MD had little effect on any protein handling systems in N27 cells. The effect of NQO1 on quinone induced protein handling changes and toxicity was examined using N27 cells stably transfected with NQO1 to generate an isogenic NQO1-overexpressing line. NQO1 protected against BQ–induced apoptosis but led to a potentiation of AC- and MD-induced apoptosis. Modulation of quinone-induced apoptosis in N27 and NQO1-overexpressing cells correlated only with changes in the ER stress response and not with changes in other protein handling systems. These data suggested that NQO1 modulated the ER stress response to potentiate toxicity of AC and MD, but protected against BQ toxicity. We further demonstrated that NQO1 mediated reduction to unstable hydroquinones and subsequent redox cycling was important for the activation of the ER stress response and toxicity for both AC and MD. In summary, our data demonstrate that quinone-specific changes in protein handling are evident in N27 cells and the induction of the ER stress response is associated with quinone-mediated toxicity. - Highlights: • Unstable hydroquinones contributed to quinone-induced ER stress and toxicity

  18. Quinone-induced protein handling changes: Implications for major protein handling systems in quinone-mediated toxicity

    Energy Technology Data Exchange (ETDEWEB)

    Xiong, Rui; Siegel, David; Ross, David, E-mail: david.ross@ucdenver.edu

    2014-10-15

    Para-quinones such as 1,4-Benzoquinone (BQ) and menadione (MD) and ortho-quinones including the oxidation products of catecholamines, are derived from xenobiotics as well as endogenous molecules. The effects of quinones on major protein handling systems in cells; the 20/26S proteasome, the ER stress response, autophagy, chaperone proteins and aggresome formation, have not been investigated in a systematic manner. Both BQ and aminochrome (AC) inhibited proteasomal activity and activated the ER stress response and autophagy in rat dopaminergic N27 cells. AC also induced aggresome formation while MD had little effect on any protein handling systems in N27 cells. The effect of NQO1 on quinone induced protein handling changes and toxicity was examined using N27 cells stably transfected with NQO1 to generate an isogenic NQO1-overexpressing line. NQO1 protected against BQ–induced apoptosis but led to a potentiation of AC- and MD-induced apoptosis. Modulation of quinone-induced apoptosis in N27 and NQO1-overexpressing cells correlated only with changes in the ER stress response and not with changes in other protein handling systems. These data suggested that NQO1 modulated the ER stress response to potentiate toxicity of AC and MD, but protected against BQ toxicity. We further demonstrated that NQO1 mediated reduction to unstable hydroquinones and subsequent redox cycling was important for the activation of the ER stress response and toxicity for both AC and MD. In summary, our data demonstrate that quinone-specific changes in protein handling are evident in N27 cells and the induction of the ER stress response is associated with quinone-mediated toxicity. - Highlights: • Unstable hydroquinones contributed to quinone-induced ER stress and toxicity.

  19. Handling Kids in Crisis with Care

    Science.gov (United States)

    Bushinski, Cari

    2018-01-01

    The Handle with Care program helps schools help students who experience trauma. While at the scene of an event like a domestic violence call, drug raid, or car accident, law enforcement personnel determine the names and school of any children present. They notify that child's school to "handle ___ with care" the next day, and the school…

  20. Validation of the plan of handling of hospital accustomed to waste of the Costa Rica Box of the Public Health

    International Nuclear Information System (INIS)

    Salazar Monge, F. J.

    1999-01-01

    The handling that is given at the moment to the hospital solid waste in Costa Rica is considered inadequate, due to the lack of the personnel's of cleaning training, segregation, vehicles of transport and recipients, signaling, team of personal protection, schedule and gathering route and recycle. This situation represents a serious danger for the population's health and the since environment is exposed infectious agents toxic substances and even radioactive products that are generated in the residuals of the centers of health. In this work they intend improvements to the system of handling of solid waste of the hospital Calderon Guardia, and you evaluates each one of the points mentioned previously. A revision was made about the properties, the quality and the quantity of the produced solid waste and an I diagnose of the current situation in this center of health. The proposed improvements are based on the regional program of hospital solid waste, agreement ALA91/33 (this it was elaborated in 1997 by a cooperation initiative between the European Union and the Governments from Costa Rica, El Salvador, Guatemala, Honduras, Nicaragua and Panama) and the Norms for the Handling of dangerous Solid Waste in Establishments of Health (elaborated by the Costa Rican Box of the Public Health) their advantages and disadvantages are also exposed and he/she is carried out a comparative analysis among the handling plan proposed in these documents and the one that is used at the moment in the Calderon Guardia hospital. Some of the detected problems are: it lacks of team of personal protection, the appropriate recipients are not used, storage of waste inside the hospital, the vehicles used in the internal transport are not appropriate, bad organization of the storing center, among others [es

  1. Progressing quality control in environmental impact assessment beyond legislative compliance: An evaluation of the IEMA EIA Quality Mark certification scheme

    International Nuclear Information System (INIS)

    Bond, Alan; Fischer, Thomas B; Fothergill, Josh

    2017-01-01

    The effectiveness of Environmental Impact Assessment (EIA) systems is contingent on a number of control mechanisms: procedural; judicial; evaluative; public and government agency; professional; and development aid agency. If we assume that procedural and judicial controls are guaranteed in developed EIA systems, then progressing effectiveness towards an acceptable level depends on improving the performance of other control mechanisms over time. These other control mechanisms are either absent, or are typically centrally controlled, requiring public finances; this we argue is an unpopular model in times of greater Government austerity. Here we evaluate a market-based mechanism for improving the performance of evaluative and professional control mechanisms, the UK Institute of Environmental Management and Assessments' EIA Quality Mark. We do this by defining dimensions of effectiveness for the purposes of our evaluation, and by identifying international examples of the approaches taken to delivering the other control measures to validate the approach taken in the EIA Quality Mark. We then evaluate the EIA Quality Mark, when used in combination with legal procedures and an active judiciary, against the effectiveness dimensions and use time-series analysis of registrant data to examine its ability to progress practice. We conclude that the EIA Quality Mark has merit as a model for a market-based mechanism, and may prove a more financially palatable approach for delivering effective EIA in mature systems in countries that lack centralised agency oversight. It may, therefore, be of particular interest to some Member States of the European Union for ensuring forthcoming certification requirements stemming from recent amendments to the EIA Directive. - Highlights: • Quality control mechanisms in EIA are identified. • Effectiveness of EIA is conceptualised for evaluation purposes. • The UK IEMA EIA Quality Mark is introduced as a market-based mechanism. • The

  2. Progressing quality control in environmental impact assessment beyond legislative compliance: An evaluation of the IEMA EIA Quality Mark certification scheme

    Energy Technology Data Exchange (ETDEWEB)

    Bond, Alan, E-mail: alan.bond@uea.ac.uk [School of Environmental Sciences, University of East Anglia (United Kingdom); Research Unit for Environmental Sciences and Management, North-West University (South Africa); Fischer, Thomas B, E-mail: fischer@liverpool.ac.uk [School of Environmental Sciences, University of Liverpool (United Kingdom); Fothergill, Josh, E-mail: j.fothergill@iema.net [Institute of Environmental Management and Assessment, Lincoln (United Kingdom)

    2017-03-15

    The effectiveness of Environmental Impact Assessment (EIA) systems is contingent on a number of control mechanisms: procedural; judicial; evaluative; public and government agency; professional; and development aid agency. If we assume that procedural and judicial controls are guaranteed in developed EIA systems, then progressing effectiveness towards an acceptable level depends on improving the performance of other control mechanisms over time. These other control mechanisms are either absent, or are typically centrally controlled, requiring public finances; this we argue is an unpopular model in times of greater Government austerity. Here we evaluate a market-based mechanism for improving the performance of evaluative and professional control mechanisms, the UK Institute of Environmental Management and Assessments' EIA Quality Mark. We do this by defining dimensions of effectiveness for the purposes of our evaluation, and by identifying international examples of the approaches taken to delivering the other control measures to validate the approach taken in the EIA Quality Mark. We then evaluate the EIA Quality Mark, when used in combination with legal procedures and an active judiciary, against the effectiveness dimensions and use time-series analysis of registrant data to examine its ability to progress practice. We conclude that the EIA Quality Mark has merit as a model for a market-based mechanism, and may prove a more financially palatable approach for delivering effective EIA in mature systems in countries that lack centralised agency oversight. It may, therefore, be of particular interest to some Member States of the European Union for ensuring forthcoming certification requirements stemming from recent amendments to the EIA Directive. - Highlights: • Quality control mechanisms in EIA are identified. • Effectiveness of EIA is conceptualised for evaluation purposes. • The UK IEMA EIA Quality Mark is introduced as a market-based mechanism. • The

  3. Colon irrigation and quality of life in patients with colostomy

    Directory of Open Access Journals (Sweden)

    Francisco Javier Barbero Juárez

    2004-07-01

    Full Text Available One of the most important problems that a patient with a colostomy has to face after surgery is the intestinal continence. This lead these patients to experience not only a series of physical changes but also hygienic, dietetic, social, etc. As nurses, we must learn how to detect the needs of these patients in order to offer them an appropriate attention to improve their quality of life. Our aim is to assess if the irrigation technique (IT as a method for intestinal continence improves the quality of life in these patients. Methodology: A Pretest-postest study without control group was carried out in order to evaluate the usefulness of IT to improve the quality of life in patients with colostomy. Following a normalized protocol, the technique was taught to patients whose quality of life was evaluated before and after the application of IT. Results: Quality of life rate before intervention was 54,2% and reached 77,3% (statistically significant once the patient has used IT for two months. Conclusions: IT is associated with a remarkable improvement in the quality of life of patientes with colostomy. This improvement is reflected in the eight dimensions analysed: psychological welfare, physical welfare, body image, pain, sexual activity, nutrition, social preoccupations and device handling.

  4. Self–Evaluation of Distance Learning Study Program as a Part of Internal Quality Assurance

    Directory of Open Access Journals (Sweden)

    Radojka Krneta

    2012-02-01

    Full Text Available This paper features quality assurance of specific distance learning master study program through self-evaluation. This unique program involving e-learning as the program content, as well as delivery method, is presented in the paper from the aspects of its quality assurance. Student evaluation of this study program as a part of the internal quality assurance is performed at the end of every school year in the aim of its quality assurance. Results and conclusions of self-evaluation conducted in this school year by known SEVAQ+ evaluation tool are presented here.

  5. Deaf Smith County air quality analysis: Letter report: Revision 2

    International Nuclear Information System (INIS)

    1985-11-01

    Air quality impacts due to site characterization, and repository construction and operation activities were evaluated in the Deaf Smith County Site, Texas environmental assessment (EA). The analyses on which the impact assessments are based made with dispersion models recommended by the EPA for such applications, meteorological data from a nearby representative National Weather Service station at Amarillo, Texas, and available background air quality data from an urban monitoring location. Maximum offsite concentrations of total suspended particulates, nitrogen dioxide, sulfur dioxide, and carbon monoxide were estimated for periods of maximum emissions identified for each pollutant. Estimates of total annual salt deposition resulting from repository salt handling operations were also made. 36 refs., 5 figs., 17 tabs

  6. Radionuclide Data Quality Evaluation Guidance

    International Nuclear Information System (INIS)

    Tucker, B.J.; Winters, M.S.; Evans, D.

    2009-01-01

    A considerable amount of radioanalytical data is generated during various phases of the characterization and remediation of radiologically-contaminated sites and properties. It is critical that data generated from the analysis of collected samples be to a level of quality usable by the project and acceptable to stakeholders. In July 2004, the final version of a multi-agency guidance manual entitled Multi-Agency Radiological Analytical Protocols Manual (MARLAP) was issued by the Environmental Protection Agency, Department of Energy, Department of Homeland Security, Nuclear Regulatory Commission, Department of Defense, National Institute of Standards and Technology, U. S. Geological Survey, Food and Drug Administration, and the States of Kentucky and California. The authors' purpose is to introduce readers to some key elements of MARLAP as it relates to radioanalytical lab quality control, and to demonstrate how these guidance elements can be effectively incorporated into mature radioanalytical lab operations and data validation regimes. Based upon the logic and statistical methodologies presented in MARLAP, the authors have revised existing project-specific Radioanalytical Data Evaluation Guidance (RadDEG) used at the FUSRAP Maywood Site in Maywood, NJ. The RadDEG allows users to qualify data in a meaningful way by tying the usability of the data to its activity and uncertainty relative to project action levels and QC results. This exercise may be useful to other projects looking to implement a MARLAP-based approach into their project/site-specific data evaluation methodologies. (authors)

  7. Survey of tritiated oil sources and handling practices

    International Nuclear Information System (INIS)

    Miller, J.M.

    1994-08-01

    Tritium interactions with oil sources (primarily associated with pumps) in tritium-handling facilities can lead to the incorporation of tritium in the oil and the production of tritiated hydrocarbons. This results in a source of radiological hazard and the need for special handling considerations during maintenance, decontamination, decommissioning and waste packaging and storage. The results of a general survey of tritiated-oil sources and their associated characteristics, handling practices, analysis techniques and waste treatment/storage methods are summarized here. Information was obtained from various tritium-handling laboratories, fusion devices, and CANDU plants. 38 refs., 1 fig

  8. Effects of handling on fear reactions in young Icelandic horses

    DEFF Research Database (Denmark)

    Marsbøll, Anna Feldberg; Christensen, Janne Winther

    2015-01-01

    To investigate the effect of a short-term standardised handling procedure on reactions of young horses in 2 types of fear tests (including and excluding human handling). Study design An experimental study with 3-year-old Icelandic horses (n = 24). Methods Handled horses (n = 12) were trained according...... to a standardised handling procedure whereas controls (n = 12) remained untrained. Behavioural and heart rate responses in a novel object test and 2 handling fear tests (HFTs) were measured. The HFTs were conducted with both an unknown (HFT-unknown) and a known handler (HFT-known). Results There was no effect...... correlated significantly between tests. Conclusions Previous handling may affect the behavioural fear response of horses when handled by their usual handler, whereas this effect did not apply to an unknown handler. Heart rates appeared unaffected by handling and may be a more reliable indicator...

  9. Consumer food handling in the home: a review of food safety studies.

    Science.gov (United States)

    Redmond, Elizabeth C; Griffith, Christopher J

    2003-01-01

    Epidemiological data from Europe, North America, Australia, and New Zealand indicate that a substantial proportion of foodborne disease is attributable to improper food preparation practices in consumers' homes. International concern about consumer food safety has prompted considerable research to evaluate domestic food-handling practices. The majority of consumer food safety studies in the last decade have been conducted in the United Kingdom and Northern Ireland (48%) and in the United States (42%). Surveys (questionnaires and interviews), the most frequent means of data collection, were used in 75% of the reviewed studies. Focus groups and observational studies have also been used. One consumer food safety study examined the relationship between pathogenic microbial contamination from raw chicken and observed food-handling behaviors, and the results of this study indicated extensive Campylobacter cross-contamination during food preparation sessions. Limited information about consumers' attitudes and intentions with regard to safe food-handling behaviors has been obtained, although a substantial amount of information about consumer knowledge and self-reported practices is available. Observation studies suggest that substantial numbers of consumers frequently implement unsafe food-handling practices. Knowledge, attitudes, intentions, and self-reported practices did not correspond to observed behaviors, suggesting that observational studies provide a more realistic indication of the food hygiene actions actually used in domestic food preparation. An improvement in consumer food-handling behavior is likely to reduce the risk and incidence of foodborne disease. The need for the development and implementation of food safety education strategies to improve specific food safety behaviors is reviewed in this paper.

  10. Regional action plan handling of social welfare problem in nganjuk regency

    Science.gov (United States)

    Zain, IM; Utami, WS; Setyawan, KG

    2018-01-01

    Local action plans are expected to ensure a social protection for vulnerable and disadvantaged groups or PMKS. The method used in this research is by primary survey and secondary survey. The condition of the people who still belong to PMKS requires the state to come to the community to solve the problems faced. Stakeholders should be involved to handle PMKS. The activities presented should also receive periodic monitoring and evaluation so that there is progress reporting at any time. Implementable poverty reduction strategies and policies are social protection strategies, opportunity expansion strategies, resource capacity building strategies, community empowerment strategies and partnership strategies. The flow of PMKS is the validation and updating of data, the fulfillment of the basic needs of the PMKS family, the development of PMKS human resources, the improvement of the quality of life for poor families, the institutions of poverty alleviation stakeholders and the unemployed at the base level. The Regional Action Plan (RAP) is prepared as a reference in the context of carrying out PMKS mitigation which is expected to serve as a guide for managers and program implementers with relevant agencies that are conducted jointly and continuously for the period of time specified.

  11. UNCERTANITIES AND RISK IN GEOLOGICAL ACTIVITIES AND NEW WAYS OF THEIR HANDLING

    Directory of Open Access Journals (Sweden)

    Gyorgy Bardossy

    2001-12-01

    Full Text Available The authors rewiev the main types of uncertainties occuring in connection with geological investigations. The general concept of handling these uncertainties are outlined. The particular features of scalar, spatial and spatial-temporal evaluations are presented. Limitations of the traditional mathematical approach – deterministic and probabilistic – applied to geological investigations are discused. In the second part of the paper nem mathematical methods are presented that are more suitable to handle uncertaintes that the traditional ones.The fuzzy set theory seems to be one of the most efficient for geological purposes, among these methods. The problems of uncertainty in risk analysis are shortly discussed. Finally, results of test calculations performed by fuzzy arithmetic are presented.

  12. Evaluating radiographers' diagnostic accuracy in screen-reading mammograms: what constitutes a quality study?

    International Nuclear Information System (INIS)

    Debono, Josephine C; Poulos, Ann E

    2015-01-01

    The aim of this study was to first evaluate the quality of studies investigating the diagnostic accuracy of radiographers as mammogram screen-readers and then to develop an adapted tool for determining the quality of screen-reading studies. A literature search was used to identify relevant studies and a quality evaluation tool constructed by combining the criteria for quality of Whiting, Rutjes, Dinnes et al. and Brealey and Westwood. This constructed tool was then applied to the studies and subsequently adapted specifically for use in evaluating quality in studies investigating diagnostic accuracy of screen-readers. Eleven studies were identified and the constructed tool applied to evaluate quality. This evaluation resulted in the identification of quality issues with the studies such as potential for bias, applicability of results, study conduct, reporting of the study and observer characteristics. An assessment of the applicability and relevance of the tool for this area of research resulted in adaptations to the criteria and the development of a tool specifically for evaluating diagnostic accuracy in screen-reading. This tool, with further refinement and rigorous validation can make a significant contribution to promoting well-designed studies in this important area of research and practice

  13. A framework for assessing Health Economic Evaluation (HEE) quality appraisal instruments.

    Science.gov (United States)

    Langer, Astrid

    2012-08-16

    Health economic evaluations support the health care decision-making process by providing information on costs and consequences of health interventions. The quality of such studies is assessed by health economic evaluation (HEE) quality appraisal instruments. At present, there is no instrument for measuring and improving the quality of such HEE quality appraisal instruments. Therefore, the objectives of this study are to establish a framework for assessing the quality of HEE quality appraisal instruments to support and improve their quality, and to apply this framework to those HEE quality appraisal instruments which have been subject to more scrutiny than others, in order to test the framework and to demonstrate the shortcomings of existing HEE quality appraisal instruments. To develop the quality assessment framework for HEE quality appraisal instruments, the experiences of using appraisal tools for clinical guidelines are used. Based on a deductive iterative process, clinical guideline appraisal instruments identified through literature search are reviewed, consolidated, and adapted to produce the final quality assessment framework for HEE quality appraisal instruments. The final quality assessment framework for HEE quality appraisal instruments consists of 36 items organized within 7 dimensions, each of which captures a specific domain of quality. Applying the quality assessment framework to four existing HEE quality appraisal instruments, it is found that these four quality appraisal instruments are of variable quality. The framework described in this study should be regarded as a starting point for appraising the quality of HEE quality appraisal instruments. This framework can be used by HEE quality appraisal instrument producers to support and improve the quality and acceptance of existing and future HEE quality appraisal instruments. By applying this framework, users of HEE quality appraisal instruments can become aware of methodological deficiencies

  14. Handling wood shavings

    Energy Technology Data Exchange (ETDEWEB)

    1974-09-18

    Details of bulk handling equipment suitable for collection and compressing wood waste from commercial joinery works are discussed. The Redler Bin Discharger ensures free flow of chips from storage silo discharge prior to compression into briquettes for use as fuel or processing into chipboard.

  15. Translator for Optimizing Fluid-Handling Components

    Science.gov (United States)

    Landon, Mark; Perry, Ernest

    2007-01-01

    A software interface has been devised to facilitate optimization of the shapes of valves, elbows, fittings, and other components used to handle fluids under extreme conditions. This software interface translates data files generated by PLOT3D (a NASA grid-based plotting-and- data-display program) and by computational fluid dynamics (CFD) software into a format in which the files can be read by Sculptor, which is a shape-deformation- and-optimization program. Sculptor enables the user to interactively, smoothly, and arbitrarily deform the surfaces and volumes in two- and three-dimensional CFD models. Sculptor also includes design-optimization algorithms that can be used in conjunction with the arbitrary-shape-deformation components to perform automatic shape optimization. In the optimization process, the output of the CFD software is used as feedback while the optimizer strives to satisfy design criteria that could include, for example, improved values of pressure loss, velocity, flow quality, mass flow, etc.

  16. Safety climate and attitude as evaluation measures of organizational safety.

    Science.gov (United States)

    Isla Díaz, R; Díaz Cabrera, D

    1997-09-01

    The main aim of this research is to develop a set of evaluation measures for safety attitudes and safety climate. Specifically it is intended: (a) to test the instruments; (b) to identify the essential dimensions of the safety climate in the airport ground handling companies; (c) to assess the quality of the differences in the safety climate for each company and its relation to the accident rate; (d) to analyse the relationship between attitudes and safety climate; and (e) to evaluate the influences of situational and personal factors on both safety climate and attitude. The study sample consisted of 166 subjects from three airport companies. Specifically, this research was centered on ground handling departments. The factor analysis of the safety climate instrument resulted in six factors which explained 69.8% of the total variance. We found significant differences in safety attitudes and climate in relation to type of enterprise.

  17. Evaluating service quality in the Durban freight transportation industry

    Directory of Open Access Journals (Sweden)

    Jeevarathnam P. Govender

    2011-11-01

    Full Text Available This paper evaluates service quality in the Durban freight transportation industry, in which a high degree of competition exists. Previous measurements of service quality in the industry have been casual gauges, rather than a formalised process. This paper makes a contribution by examining the level of service quality, specifically from a tangibles, reliability and responsiveness perspective, thereby identifying service quality gaps which need to be closed, with a view to raising service quality levels in the industry. The SERVQUAL instrument has been used to measure service quality levels administered to 500 of the industry’s active customers, i.e. organisations utilising the services of the freight transportation industry. The targeted respondents were managers responsible for logistics in their organisations. It was found that gaps existed between expectations and perceptions of service quality on 14 of the 15 measured items. Recommendations are made as to how the industry can improve its service quality levels.

  18. Manual on safe production, transport, handling and storage of uranium hexafluoride

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-11-01

    This document includes a description of the physical, chemical and radiological properties of UF{sub 6} and related products, including information concerning their production, handling, storage and transportation and the management of the wastes which result. All the operations of UF{sub 6} management are considered form a safety point of view. The IAEA organized a series of meetings to consider the hazards of UF{sub 6} transport since considerable quantities of depleted, natural and enriched UF{sub 6} are transported between nuclear fuel sites. Storage of depleted UF{sub 6} is another important issue. Factors affecting long term storage are presented, especially site choice and cylinder corrosion. Other topics such as waste management, quality assurance and emergency preparedness which contribute to the overall safety of UF{sub 6} handling, are included. The intention of this document is to provide analysis of the safety implications of all stages of UF{sub 6} operations and to draw attention to specific features and properties of importance. 38 refs, figs, tabs.

  19. Handling of bulk solids theory and practice

    CERN Document Server

    Shamlou, P A

    1990-01-01

    Handling of Bulk Solids provides a comprehensive discussion of the field of solids flow and handling in the process industries. Presentation of the subject follows classical lines of separate discussions for each topic, so each chapter is self-contained and can be read on its own. Topics discussed include bulk solids flow and handling properties; pressure profiles in bulk solids storage vessels; the design of storage silos for reliable discharge of bulk materials; gravity flow of particulate materials from storage vessels; pneumatic transportation of bulk solids; and the hazards of solid-mater

  20. Torus sector handling system

    International Nuclear Information System (INIS)

    Grisham, D.L.

    1981-01-01

    A remote handling system is proposed for moving a torus sector of the accelerator from under the cryostat to a point where it can be handled by a crane and for the reverse process for a new sector. Equipment recommendations are presented, as well as possible alignment schemes. Some general comments about future remote-handling methods and the present capabilities of existing systems will also be included. The specific task to be addressed is the removal and replacement of a 425 to 450 ton torus sector. This requires a horizontal movement of approx. 10 m from a normal operating position to a point where its further transport can be accomplished by more conventional means (crane or floor transporter). The same horizontal movement is required for reinstallation, but a positional tolerance of 2 cm is required to allow reasonable fit-up for the vacuum seal from the radial frames to the torus sector. Since the sectors are not only heavy but rather tall and narrow, the transport system must provide a safe, stable, and repeatable method fo sector movement. This limited study indicates that the LAMPF-based method of transporting torus sectors offers a proven method of moving heavy items. In addition, the present state of the art in remote equipment is adequate for FED maintenance

  1. Evaluating the Effect of Software Quality Characteristics on Health Care Quality Indicators

    Directory of Open Access Journals (Sweden)

    Sakineh Aghazadeh

    2015-07-01

    Full Text Available Introduction: Various types of software are used in health care organizations to manage information and care processes. The quality of software has been an important concern for both health authorities and designers of Health Information Technology. Thus, assessing the effect of software quality on the performance quality of healthcare institutions is essential. Method: The most important health care quality indicators in relation to software quality characteristics are provided via an already performed literature review. ISO 9126 standard model is used for definition and integration of various characteristics of software quality. The effects of software quality characteristics and sub-characteristics on the healthcare indicators are evaluated through expert opinion analyses. A questionnaire comprising of 126 questions of 10-point Likert scale was used to gather opinions of experts in the field of Medical/Health Informatics. The data was analyzed using Structural Equation Modeling. Results: Our findings showed that software Maintainability was rated as the most effective factor on user satisfaction (R2 =0.89 and Functionality as the most important and independent variable affecting patient care quality (R2 =0.98. Efficiency was considered as the most effective factor on workflow (R2 =0.97, and Maintainability as the most important factor that affects healthcare communication (R2 =0.95. Usability and Efficiency were rated as the most effectual factor affecting patient satisfaction (R2 =0.80, 0.81. Reliability, Maintainability, and Efficiency were considered as the main factors affecting care costs (R2 =0.87, 0.74, 0.87. Conclusion: We presented a new model based on ISO standards. The model demonstrates and weighs the relations between software quality characteristics and healthcare quality indicators. The clear relationships between variables and the type of the metrics and measurement methods used in the model make it a reliable method to assess

  2. Operating the plant, quality assurance, and the job of the operating staff, Volume Twelve

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Subject matter includes operating the plant (the role of the operator, the control room, plant technical specifications, plant operating procedures, initial startup program, BWR/PWR plant startup, BWR/PWR steady state power operation, BWR/PWR transient operation, emergency operation), quality assurance (what is quality, what is quality control, quality assurance includes quality control, government regulation and quality assurance, administrative controls for nuclear power plants, the necessity of reviews and audits, practical quality assurance), and the job of the operating staff (the plant operating staff, plant safety, first aid and resuscitation, general plant hazards, personnel protective equipment, handling chemicals, handling compressed gas, equipment repair and maintenance, communicating with others

  3. [Systematic economic assessment and quality evaluation for traditional Chinese medicines].

    Science.gov (United States)

    Sun, Xiao; Guo, Li-ping; Shang, Hong-cai; Ren, Ming; Lei, Xiang

    2015-05-01

    To learn about the economic studies on traditional Chinese medicines in domestic literatures, in order to analyze the current economic assessment of traditional Chinese medicines and explore the existing problems. Efforts were made to search CNKI, VIP, Wanfang database and CBM by computer and include all literatures about economic assessment of traditional Chinese medicines published on professional domestic journals in the systematic assessment and quality evaluation. Finally, 50 articles were included in the study, and the systematic assessment and quality evaluation were made for them in terms of titles, year, authors' identity, expense source, disease type, study perspective, study design type, study target, study target source, time limit, cost calculation, effect indicator, analytical technique and sensitivity analysis. The finally quality score was 0.74, which is very low. The results of the study showed insufficient studies on economics of traditional Chinese medicines, short study duration and simple evaluation methods, which will be solved through unremitting efforts in the future.

  4. Research Quality Plus (RQ+) A Holistic Approach to Evaluating Research

    Energy Technology Data Exchange (ETDEWEB)

    McLean, R.K.D.; Feinstein, O.N.

    2016-07-01

    The International Development Research Centre (IDRC) strives to fund excellence in research - defining excellence as, {sup m}ethodologically sound, evidence-based, and scientifically robust{sup .} But how is the concept of excellence identified and evaluated across the diverse range of research the IDRC supports? The Research Quality Plus (RQ+) Assessment Framework was developed in order to address these complex issues. It provides a systems-informed approach to defining and evaluating the quality of research, and its positioning for use and impact. It allows tailoring to context, values, mandate and purpose, and can support planning, management and learning processes at any stage in the lifetime of a research project, program or grants portfolio. This paper presents: 1) the rationale for RQ+ creation, 2) the RQ+ Assessment Framework, and how it can be adapted and used, 3) our early experiences applying it in a series of extenal evaluations of research quality. The paper is presented by an RQ+ designer and an external user. (Author)

  5. Ior-CEA-1: Labelling, quality control and clinical evaluation

    International Nuclear Information System (INIS)

    Pimentel, G.J.

    1998-01-01

    Within the Co-ordinated Programme on Labelling, Quality Control and Evaluation of Monoclonal Antibodies, the IAEA has made a great effort to expand efficient labelling methods, mainly those with radioisotopes which have been used for radioimmunoscintigraphy. In this sense, more recently 99 Tc m has been mostly employed in the majority of the investigations due to its ideal physical characteristics. Efficient labelling of monoclonal antibodies depends on a number of factors including the method and way of the label incorporation into the protein. During the last years several direct labelling approaches have been developed, which led to attain simple and inexpensive methods for medical practice, as well as safe and stable techniques which bring accurate and good quality images. Accordingly, this paper describes the results obtained during last five years which come from the comparison among different labelling systems, passing through the quality control to test the labelled monoclonal stability and the protein bioreactivity, to continue in the clinical evaluation of ior-CEA-1, as well as the evaluation of other antibodies. Up to now we have evaluated more than 70 patients with the anti-CEA monoclonal antibody (ior-CEA-1), examined in different clinical assays such as: pilot, phase I-II and extensive phase III-IV trials, whose results are encouraging. It confirms that the employed labelling approach was safe and adequate

  6. Research on Holographic Evaluation of Service Quality in Power Data Network

    Science.gov (United States)

    Wei, Chen; Jing, Tao; Ji, Yutong

    2018-01-01

    With the rapid development of power data network, the continuous development of the Power data application service system, more and more service systems are being put into operation. Following this, the higher requirements for network quality and service quality are raised, in the actual process for the network operation and maintenance. This paper describes the electricity network and data network services status. A holographic assessment model was presented to achieve a comprehensive intelligence assessment on the power data network and quality of service in the operation and maintenance on the power data network. This evaluation method avoids the problems caused by traditional means which performs a single assessment of network performance quality. This intelligent Evaluation method can improve the efficiency of network operation and maintenance guarantee the quality of real-time service in the power data network..

  7. [The haematological biobank--an infrastructure for quality assurance, development and research].

    Science.gov (United States)

    Johnsen, Hans E; Pilgaard, Linda; Højfeldt, Anne Dirks; Andersson, Torben Lüth; Schmitz, Alexander; Gade, Katrine Hindborg; Fogd, Kirsten; Nyegaard, Mette; Bøgsted, Martin; Dybkær, Karen

    2011-05-23

    Archived patient samples of biological material coupled to clinical databases are valuable and hold the potential to improve patient care, quality control, research and development. Biobanks form a catalytic infrastructure which ensures the registration, handling and storage of collected biological material. Here, we describe the Haematology Biobank and stress the significance of a registration database. Together, these form the basis for retrospective validation of clinical progress and prognostic evaluation of new diagnostic methods, which can therefore be more quickly implemented in the clinic.

  8. Getting to grips with remote handling and robotics

    Energy Technology Data Exchange (ETDEWEB)

    Mosey, D [Ontario Hydro, Toronto (Canada)

    1984-12-01

    A report on the Canadian Nuclear Society Conference on robotics and remote handling in the nuclear industry, September 1984. Remote handling in reactor operations, particularly in the Candu reactors is discussed, and the costs and benefits of use of remote handling equipment are considered. Steam generator inspection and repair is an area in which practical application of robotic technology has made a major advance.

  9. Assessment of the quality of pharmacoeconomic evaluation literature in China.

    Science.gov (United States)

    Zhang, Fang; He, Xu; Xiang, Wei; Li, Shu Chuen

    2017-05-01

    To evaluate the quality of Chinese pharmacoeconomic-evaluation literature published between 2012-2014 retrieved from the Chinese National Knowledge Infrastructure (CNKI) in order to assess their adherence to recommendations of the Chinese Pharmacoeconomic Guidelines. Identified literature was screened according to pre-specified criteria to access legibility for inclusion. Each included piece of literature was systematically compared against the recommendations proposed by the relevant Chinese guidelines. After culling, 259 studies were included in the comparative analysis. When compared to a previous study evaluating the quality of similar literature published between 1997-2007, the results showed improvements in certain technical aspects over the years. Particularly, an improvement was observed in more diverse evaluation methods being used, increased use of cost-utility analysis (2.43% in 2012-2014 vs 0.26% in 1997-2007) and use of discounting (45% in 2012-2014 vs 4.35% in 1997- 2007). In addition, a small number of studies were starting to apply modeling. The quality of economic evaluation literature has improved in recent years, with more researchers realizing the importance and necessity of using discounting, sensitivity analysis, and modeling when conducting economic evaluation. This study also highlights certain important areas needing further attention when conducting economic evaluations in China. These include the ICER threshold of economic analysis, more detailed guidance in performing sensitivity analysis and modeling, as well as transferability of cost data across different regions. Overall, the results would support the positive contribution of the Chinese Economic Guideline in promoting economic evaluations in China.

  10. Handling knowledge on osteoporosis - a qualitative study

    DEFF Research Database (Denmark)

    Nielsen, Dorthe; Huniche, Lotte; Brixen, Kim

    2013-01-01

    Scand J Caring Sci; 2012 Handling knowledge on osteoporosis - a qualitative study The aim of this qualitative study was to increase understanding of the importance of osteoporosis information and knowledge for patients' ways of handling osteoporosis in their everyday lives. Interviews were...

  11. A computerized system for handling renal size measurements from urograms

    International Nuclear Information System (INIS)

    Claesson, I.; Jacobsson, B.F.; Riha, M.

    1987-01-01

    The size of a kidney, as measured on an urogram, is a sensitive indicator of renal damage in a child with urinary tract infection, and renal surface area correlates well with glomerular filtration rate. Sequential measurements can be invaluable in evaluating the efficacy of a regimen of treatment. A system utilizing a personal microcomputer has been developed to facilitate the measuring procedure and the handling and analysis of data. (orig.)

  12. Evaluation of indoor air quality in a department of radiation oncology located underground

    International Nuclear Information System (INIS)

    Kim, Won Taek; Kwon, Byung Hyun; Kang, Dong Mug; Ki, Yong Kan; Kim, Dong Won; Shin, Yong Chul

    2005-01-01

    Indoor air quality (IAQ) in the radiation treatment center which is generally located underground is important to the health of hospital workers and patients treated over a long period of time. This study was conducted to measure and analyze the factors related to IAQ and subjective symptoms of sick building syndrome, and to establish the causes influencing IAQ and find a solution to the problems. Self administrated questionnaire was conducted to check the workers' symptoms and understanding of the work environment. Based on a preliminary investigation, the factors related to IAQ such as temperature, humidity, fine particulate, carbon dioxide, carbon monoxide, formaldehyde, total volatile organic compounds (TVOC), and radon gas were selected and measured for a certain period of time in specific sites where hospital workers stay long in a day. And we also evaluated the surrounding environment and the efficiency of the ventilating system simultaneously, and measured the same factors at the first floor (outdoor) to compare with outdoor air quality. All collected data were assessed by the recommended standard for IAQ of the domestic and international environmental organizations. Hospital workers were discontented with foul odors, humidity and particulate. They complained symptoms related to musculo-skeletal system, neurologic system, and mucosal-irritation. Most of the factors were not greater than the recommended standard, but the level of TVOC was third or fourth times as much as the measuring level of some offices in the United States. The frequency and the amount of the ventilating system were adequate, however, the problem arising in the position of outdoor-air inlets and indoor-air outlets involved a risk of the indraft of contaminated air. A careful attention was a requirement in handling and keeping chemical substances including a developing solution which has a risk of TVOC emissions, and repositioning the ventilating system was needed to solve the

  13. FY 1984 annual report on the research and development of automatic sewing systems. Cloth handling techniques; 1984 nendo jido hosei system no kenkyu kaihatsu seika hokokusho. Kiji handling gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1985-03-01

    The automatic sewing system technique research association has been commissioned by the Agency of Industrial Science and Technology for (research and development of automatic sewing systems). This program covers R and D of the elementary techniques for total systems and sewing preparation/processing, sewing/assembling, cloth handling, and system management/control. This report describes the results of the R and D efforts for the cloth handling techniques. The program for the cloth handling techniques covers all techniques related to cloth movement, positioning and processing in each sewing step from cloth receiving to completion of sewing. They include the elementary techniques for (1) cloth holding, (2) high-function positioning, and (3) soft cloth transfer. The program for the techniques (1) constructs, on a trial basis, the basic or functional models, and tests and evaluates them. The program for the techniques (2) classifies work shapes, processing types and processing steps, to help select the positioning methods. The program for the techniques (3) investigates necessary conditions for transfer methods and procedures in each step. (NEDO)

  14. Redefining NHS complaint handling--the real challenge.

    Science.gov (United States)

    Seelos, L; Adamson, C

    1994-01-01

    More and more organizations find that a constructive and open dialogue with their customers can be an effective strategy for building long-term customer relations. In this context, it has been recognized that effective complaint-contact handling can make a significant contribution to organizations' attempts to maximize customer satisfaction and loyalty. Within the NHS, an intellectual awareness exists that effective complaint/contact handling can contribute to making services more efficient and cost-effective by developing customer-oriented improvement initiatives. Recent efforts have focused on redefining NHS complaint-handling procedures to make them more user-friendly and effective for both NHS employees and customers. Discusses the challenges associated with opening up the NHS to customer feedback. Highlights potential weaknesses in the current approach and argues that the real challenge is for NHS managers to facilitate a culture change that moves the NHS away from a long-established defensive complaint handling practice.

  15. 1994 Ergonomics Program Quality Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Longbotham, L.; Miller, D.P.

    1995-06-01

    A telephone survey was conducted to evaluate the quality of service provided to the primary customers of the Corporate Ergonomics Group (CEG). One hundred clients who received services between October 1993 and June 1994 were asked questions on their expectations, implementation of ergonomic recommendations, follow-ups, time required, productivity improvements, symptom alleviation, and satisfaction. Suggestions on how processes could be improved were also solicited. In general, recommendations are being implemented, worksite evaluations are going smoothly, and customers are satisfied with the process. The CEG was pleased to learn that half of the people who implemented recommendations experienced improvements in productivity, and four out of five symptomatic customers experienced partial or complete relief. Through analysis of the data and by studying clients` suggestions for process improvement, the CEG has developed a strategy for changing and improving current procedures and practices. These plans can be found in the last section of this report.

  16. Evaluation of the quality of life in a sample of workers with potential risk to ionizing radiation

    International Nuclear Information System (INIS)

    Fernandes, Ivani M.; Silva, Amanda J. da; Potiens, Maria da Penha A.; Carneiro, Janete C.G. Gaburo

    2010-01-01

    The main objective of this study was to evaluate the Quality of life (QOL) in a sample of workers of IPEN/CNEN-SP, with potential risk to ionizing radiation; It aims also identify the social-demographic factors related to the workers and its influence on QOL as well to draw the workers profile who handling radioactive material. A quantitative, descriptive and exploratory study was carried out from March to April, 2009 at Radiopharmacy Directory of IPEN. The data were collected by a questionnaire with questions about social-demographic characteristics, working conditions the participants and the WHOQOL-Bref tool. The sample resulted in 86 answered questionnaires; representing 83.5% of the studied population which 80.2% of individuals were male. The mean age of individuals was 47.8 +- 7.0 years and the educational level was high, 55.8% with graduation. Regarding marital status, 74.4% were married. The average score on each domain of the WHOQOL-Bref was: physical (75.2), psychological (75.9), social (72.8) and environmental (62.5). The WHOQOL-Bref showed to be an adequate instrument with easy application for evaluation the QOL of workers exposed to ionizing radiation. The study provided an overview of the perception of QOL of the studied group based on the interviewees as reported by workers. (author)

  17. Evaluation of Ecological Environmental Quality in a Coal Mining Area by Modelling Approach

    Directory of Open Access Journals (Sweden)

    Chaodong Yan

    2017-07-01

    Full Text Available The purpose of this study was to explore the effective method of the comprehensive evaluation of ecological environmental quality in a coal mining area. Firstly, we analyzed the ecological environmental effect of the coal mining area according to Pigovian Tax theory and, according to the results of the analysis and the demand for the selection of evaluation indices by the comprehensive evaluation, built the corresponding comprehensive evaluation index system. We then used the correlation function method to determine the relative weights of each index. We determined the basic standards of a comprehensive evaluation of ecological environmental quality in a coal mining area according to the actual situation of ecological environmental quality assessments in coal mining areas in our country and the relevant provisions of the government. On this basis, we built the two-level extension comprehensive evaluation model for the evaluation of ecological environmental quality in mining areas. Finally, we chose a certain coal mining area of Yanzhou Coal Mining Company Limited as the specific case. We used the relevant statistic data, technical and economic indices and the extension evaluation model to do the applied research of the comprehensive evaluation and tested the effectiveness of the comprehensive evaluation model.

  18. Quality evaluation of radiotherapy treatment planning using 3-dimensional CT images

    International Nuclear Information System (INIS)

    Araki, Yutaka; Isobe, Yoshihide; Ozaki, Shin; Hosoki, Takuya; Mori, Shigeru; Ikeda, Hiroshi.

    1984-01-01

    Recently superimposition of dose distribution onto CT images has become available with the use of planning computers. However, the distribution is mostly along the plane of central axis of the beam, and evaluation of the quality of planning has not yet been established. In this paper, a method to evaluate the quality is demonstrated, using the extended definitions of ICRU 29 concept in to 3-dimensions. Therapeutic efficiency (Target Volume dose/Treatment Volume dose) is the main key to evaluate it. Concept and procedures are described in detail with two case examples. (author)

  19. Quality image and incident air kerma evaluation in X-ray chest exams

    International Nuclear Information System (INIS)

    Campos de O, P. M.; Do Carmo S, P.; De Sousa L, M. A.; Da Silva, T. A.

    2017-10-01

    The procedures optimization for obtaining diagnostic quality images is an important factor to the patients radiation levels submitted to diagnostic radiology examinations was the lowest as reasonably practicable. Two methodologies for image quality parameters evaluation were applied in the routine of three diagnostic radiology clinics (A, B and C), two with digital image processing and one with chemical processing in Belo Horizonte, Brazil. The incident air kerma was evaluated for the radiographic techniques used in the clinic routine chest exams, approved in accordance with European Image Quality Criteria. It was possible to determine that the Fluke Biomedical X-ray Phantom test objects coupled to the Leeds Test Objects (TOR CDR) obtained better results than Gammex s Radiographic Survey Phantom (RSV), because the low and high contrast structures present in the RSV were not visualized in lower energies. The three clinics presented very similar results in all image quality parameters in the evaluation with the TOR CDR test object. However, clinic C presented an low contrast structures result 28.1 % lower than clinical B, although the average Ka,i to obtain their images was 33.4 % superior. The clinic A results present the best relation between image quality and radiation dose in patients. It was verified the optimization doses possibility in diagnostic radiology services with digital processing system, without significant reduction in image quality. Patients submitted to the highest radiation levels belonged to the clinic that presented the worst results in the image quality parameters evaluated. (Author)

  20. Evaluation of Environmental Quality Productive Ecosystem Guayas (Ecuador).

    Science.gov (United States)

    Pozo, Wilson; Pardo, Francisco; Sanfeliu, Teófilo; Carrera, Gloria; Jordan, Manuel; Bech, Jaume; Roca, Núria

    2015-04-01

    Natural resources are deteriorating very rapidly in the Gulf of Guayaquil and the area of influence in the Guayas Basin due to human activity. Specific problems are generated by the mismanagement of the aquaculture industry affecting the traditional agricultural sectors: rice, banana, sugarcane, cocoa, coffee, and soya also studied, and by human and industrial settlements. The development of industrial activities such as aquaculture (shrimp building for shrimp farming in ponds) and agriculture, have increasingly contributed to the generation of waste, degrading and potentially toxic elements in high concentrations, which can have adverse effects on organisms in the ecosystems, in the health of the population and damage the ecological and environmental balance. The productive Guayas ecosystem, consists of three interrelated ecosystems, the Gulf of Guayaquil, the Guayas River estuary and the Guayas Basin buffer. The objective of this study was to evaluate the environmental quality of the productive Guayas ecosystem (Ecuador), through operational and specific objectives: 1) Draw up the transition coastal zone in the Gulf of Guayaquil, 2) Set temporal spatial variability of soil salinity in wetlands rice, Lower Guayas Basin, 3) evaluate the heavy metals in wetland rice in the Lower Basin of Guayas. The physical and chemical parameters of the soils have been studied. These are indicators of environmental quality. The multivariate statistical method showed the relations of similarities and dissimilarities between variables and parameter studies as stable. Moreover, the boundaries of coastal transition areas, temporal spatial variability of soil salinity and heavy metals in rice cultivation in the Lower Basin of Guayas were researched. The sequential studies included and discussed represent a broad framework of fundamental issues that has been valued as a basic component of the productive Guayas ecosystem. They are determinants of the environmental quality of the Guayas