WorldWideScience

Sample records for handling machine readable

  1. Machine Readable Passports & The Visa Waiver Programme

    CERN Multimedia

    2003-01-01

    From 1 October 2003, all passengers intending to enter the USA on the Visa Waiver Programme (VWP) will be required to present a machine-readable passport (MRP). Passengers travelling to the USA with a non-machine readable passport will require a valid US entry visa. Applying for a US visa is a lengthy process, which can take several weeks or even months. Therefore it is strongly recommended that: • All Visa Waiver nationals who hold a non-machine readable passport should obtain a MRP before their next visit to the USA. • Children travelling on a parent's passport (be it machine readable or non-machine readable) cannot benefit from the Visa Waiver Programme and should obtain their own MRP prior to travelling to the USA or request a visa. What is a Machine Readable Passport (MRP)? A MRP has the holders' personal details, e.g. name, date of birth, nationality and their passport number contained in two lines of text at the base of the photo page. This text may be read by machine. These 2 lines ...

  2. 6 CFR 37.19 - Machine readable technology on the driver's license or identification card.

    Science.gov (United States)

    2010-01-01

    ... 6 Domestic Security 1 2010-01-01 2010-01-01 false Machine readable technology on the driver's..., Verification, and Card Issuance Requirements § 37.19 Machine readable technology on the driver's license or identification card. For the machine readable portion of the REAL ID driver's license or identification card...

  3. A survey of machine readable data bases

    Science.gov (United States)

    Matlock, P.

    1981-01-01

    Forty-two of the machine readable data bases available to the technologist and researcher in the natural sciences and engineering are described and compared with the data bases and date base services offered by NASA.

  4. Combined machine-readable and visually authenticated optical devices

    Science.gov (United States)

    Souparis, Hugues

    1996-03-01

    Optical variable devices are now widely used on documents or values. The most recent optical visual features with high definition, animation, brightness, special color tune, provide excellent first and second levels of authentication. Human eye is the only instrument required to check the authenticity. This is a major advantage of OVDs in many circumstances, such as currency exchange, ID street control . . . But, under other circumstances, such as automatic payments with banknotes, volume ID controls at boarders, ID controls in shops . . . an automatic authentication will be necessary or more reliable. When both a visual and automated authentication are required, the combination, on the same security component, of a variable image and a machine readable optical element is a very secure and cost effective solution for the protection of documents. Several techniques are now available an can be selected depending upon the respective roles of the machine readability and visual control.

  5. A new TLD badge with machine readable ID for fully automated readout

    International Nuclear Information System (INIS)

    Kannan, S. Ratna P.; Kulkarni, M.S.

    2003-01-01

    The TLD badge currently being used for personnel monitoring of more than 40,000 radiation workers has a few drawbacks such as lack of on-badge machine readable ID code, delicate two-point clamping of dosimeters on an aluminium card with the chances of dosimeters falling off during handling or readout, projections on one side making automation of readout difficult etc. A new badge has been designed with a 8-digit identification code in the form of an array of holes and smooth exteriors to enable full automation of readout. The new badge also permits changing of dosimeters when necessary. The new design does not affect the readout time or the dosimetric characteristics. The salient features and the dosimetric characteristics are discussed. (author)

  6. Constructing and validating readability models: the method of integrating multilevel linguistic features with machine learning.

    Science.gov (United States)

    Sung, Yao-Ting; Chen, Ju-Ling; Cha, Ji-Her; Tseng, Hou-Chiang; Chang, Tao-Hsing; Chang, Kuo-En

    2015-06-01

    Multilevel linguistic features have been proposed for discourse analysis, but there have been few applications of multilevel linguistic features to readability models and also few validations of such models. Most traditional readability formulae are based on generalized linear models (GLMs; e.g., discriminant analysis and multiple regression), but these models have to comply with certain statistical assumptions about data properties and include all of the data in formulae construction without pruning the outliers in advance. The use of such readability formulae tends to produce a low text classification accuracy, while using a support vector machine (SVM) in machine learning can enhance the classification outcome. The present study constructed readability models by integrating multilevel linguistic features with SVM, which is more appropriate for text classification. Taking the Chinese language as an example, this study developed 31 linguistic features as the predicting variables at the word, semantic, syntax, and cohesion levels, with grade levels of texts as the criterion variable. The study compared four types of readability models by integrating unilevel and multilevel linguistic features with GLMs and an SVM. The results indicate that adopting a multilevel approach in readability analysis provides a better representation of the complexities of both texts and the reading comprehension process.

  7. Toolsets for Airborne Data (TAD): Improving Machine Readability for ICARTT Data Files

    Science.gov (United States)

    Northup, E. A.; Early, A. B.; Beach, A. L., III; Kusterer, J.; Quam, B.; Wang, D.; Chen, G.

    2015-12-01

    NASA has conducted airborne tropospheric chemistry studies for about three decades. These field campaigns have generated a great wealth of observations, including a wide range of the trace gases and aerosol properties. The ASDC Toolsets for Airborne Data (TAD) is designed to meet the user community needs for manipulating aircraft data for scientific research on climate change and air quality relevant issues. TAD makes use of aircraft data stored in the International Consortium for Atmospheric Research on Transport and Transformation (ICARTT) file format. ICARTT has been the NASA standard since 2010, and is widely used by NOAA, NSF, and international partners (DLR, FAAM). Its level of acceptance is due in part to it being generally self-describing for researchers, i.e., it provides necessary data descriptions for proper research use. Despite this, there are a number of issues with the current ICARTT format, especially concerning the machine readability. In order to overcome these issues, the TAD team has developed an "idealized" file format. This format is ASCII and is sufficiently machine readable to sustain the TAD system, however, it is not fully compatible with the current ICARTT format. The process of mapping ICARTT metadata to the idealized format, the format specifics, and the actual conversion process will be discussed. The goal of this presentation is to demonstrate an example of how to improve the machine readability of ASCII data format protocols.

  8. Fuel handling machine and auxiliary systems for a fuel handling cell

    International Nuclear Information System (INIS)

    Suikki, M.

    2013-10-01

    This working report is an update for as well as a supplement to an earlier fuel handling machine design (Kukkola and Roennqvist 2006). A focus in the earlier design proposal was primarily on the selection of a mechanical structure and operating principle for the fuel handling machine. This report introduces not only a fuel handling machine design but also auxiliary fuel handling cell equipment and its operation. An objective of the design work was to verify the operating principles of and space allocations for fuel handling cell equipment. The fuel handling machine is a remote controlled apparatus capable of handling intensely radiating fuel assemblies in the fuel handling cell of an encapsulation plant. The fuel handling cell is air tight space radiation-shielded with massive concrete walls. The fuel handling machine is based on a bridge crane capable of traveling in the handling cell along wall tracks. The bridge crane has its carriage provided with a carousel type turntable having mounted thereon both fixed and telescopic masts. The fixed mast has a gripper movable on linear guides for the transfer of fuel assemblies. The telescopic mast has a manipulator arm capable of maneuvering equipment present in the fuel handling cell, as well as conducting necessary maintenance and cleaning operations or rectifying possible fault conditions. The auxiliary fuel handling cell systems consist of several subsystems. The subsystems include a service manipulator, a tool carrier for manipulators, a material hatch, assisting winches, a vacuum cleaner, as well as a hose reel. With the exception of the vacuum cleaner, the devices included in the fuel handling cell's auxiliary system are only used when the actual encapsulation process is not ongoing. The malfunctions of mechanisms or actuators responsible for the motion actions of a fuel handling machine preclude in a worst case scenario the bringing of the fuel handling cell and related systems to a condition appropriate for

  9. Fuel handling machine and auxiliary systems for a fuel handling cell

    Energy Technology Data Exchange (ETDEWEB)

    Suikki, M. [Optimik Oy, Turku (Finland)

    2013-10-15

    This working report is an update for as well as a supplement to an earlier fuel handling machine design (Kukkola and Roennqvist 2006). A focus in the earlier design proposal was primarily on the selection of a mechanical structure and operating principle for the fuel handling machine. This report introduces not only a fuel handling machine design but also auxiliary fuel handling cell equipment and its operation. An objective of the design work was to verify the operating principles of and space allocations for fuel handling cell equipment. The fuel handling machine is a remote controlled apparatus capable of handling intensely radiating fuel assemblies in the fuel handling cell of an encapsulation plant. The fuel handling cell is air tight space radiation-shielded with massive concrete walls. The fuel handling machine is based on a bridge crane capable of traveling in the handling cell along wall tracks. The bridge crane has its carriage provided with a carousel type turntable having mounted thereon both fixed and telescopic masts. The fixed mast has a gripper movable on linear guides for the transfer of fuel assemblies. The telescopic mast has a manipulator arm capable of maneuvering equipment present in the fuel handling cell, as well as conducting necessary maintenance and cleaning operations or rectifying possible fault conditions. The auxiliary fuel handling cell systems consist of several subsystems. The subsystems include a service manipulator, a tool carrier for manipulators, a material hatch, assisting winches, a vacuum cleaner, as well as a hose reel. With the exception of the vacuum cleaner, the devices included in the fuel handling cell's auxiliary system are only used when the actual encapsulation process is not ongoing. The malfunctions of mechanisms or actuators responsible for the motion actions of a fuel handling machine preclude in a worst case scenario the bringing of the fuel handling cell and related systems to a condition appropriate for

  10. 25 CFR 547.11 - What are the minimum technical standards for money and credit handling?

    Science.gov (United States)

    2010-04-01

    ... GAMES § 547.11 What are the minimum technical standards for money and credit handling? This section... interface is: (i) Involved in the play of a game; (ii) In audit mode, recall mode or any test mode; (iii...) For machine-readable vouchers and coupons, a bar code or other form of machine readable representation...

  11. Migrant Student Record Transfer System (MSRTS) [machine-readable data file].

    Science.gov (United States)

    Arkansas State Dept. of Education, Little Rock. General Education Div.

    The Migrant Student Record Transfer System (MSRTS) machine-readable data file (MRDF) is a collection of education and health data on more than 750,000 migrant children in grades K-12 in the United States (except Hawaii), the District of Columbia, and the outlying territories of Puerto Rico and the Mariana and Marshall Islands. The active file…

  12. Evaluation of the Mechanical Durability of the Egyptian Machine Readable Booklet Passport

    Directory of Open Access Journals (Sweden)

    Ahmed Mahmoud Yosri

    2013-12-01

    Full Text Available In 2008 the first Egyptian booklet Machine Readable Passport/ MRP has been issued and its security and informative standard quality levels were proved in a research published in 2011. Here the durability profiles of the Egyptian MRP have been evaluated. Seven mechanical durability tests were applied on the Egyptian MRP. Such tests are specified in the International Civil Aviation Organization / ICAO standard requirements documents. These seven very severe durability tests resulted in that the Egyptian MRP has achieved better & higher results than the values detected in ICAO-Doc N0232: Durability of Machine Readable Passports - Version: 3.2. Hence, this research had proved the complete conformance between the Egyptian MRP mechanical durability profiles to the international requirements. The Egyptian booklet MRP doesn’t need any obligatory modification concerning its mechanical durability profiles.

  13. Documentation for the machine-readable version of the Morphological Catalogue of Galaxies (MCG) of Vorontsov-Velyaminov et al, 1962-1968

    Science.gov (United States)

    Warren, W. H., Jr.

    1982-01-01

    Modifications, corrections, and the record format are provided for the machine-readable version of the "Morphological Catalogue of Galaxies.' In addition to hundreds of individual corrections, a detailed comparison of the machine-readable with the published catalogue resulted in the addition of 116 missing objects, the deletion of 10 duplicate records, and a format modification to increase storage efficiency.

  14. The compiled catalogue of galaxies in machine-readable form and its statistical investigation

    International Nuclear Information System (INIS)

    Kogoshvili, N.G.

    1982-01-01

    The compilation of a machine-readable catalogue of relatively bright galaxies was undertaken in Abastumani Astrophysical Observatory in order to facilitate the statistical analysis of a large observational material on galaxies from the Palomar Sky Survey. In compiling the catalogue of galaxies the following problems were considered: the collection of existing information for each galaxy; a critical approach to data aimed at the selection of the most important features of the galaxies; the recording of data in computer-readable form; and the permanent updating of the catalogue. (Auth.)

  15. Remote handling machines

    International Nuclear Information System (INIS)

    Sato, Shinri

    1985-01-01

    In nuclear power facilities, the management of radioactive wastes is made with its technology plus the automatic techniques. Under the radiation field, the maintenance or aid of such systems is important. To cope with this situation, MF-2 system, MF-3 system and a manipulator system as remote handling machines are described. MF-2 system consists of an MF-2 carrier truck, a control unit and a command trailer. It is capable of handling heavy-weight objects. The system is not by hydraulic but by electrical means. MF-3 system consists of a four-crawler truck and a manipulator. The truck is versatile in its posture by means of the four independent crawlers. The manipulator system is bilateral in operation, so that the delicate handling is made possible. (Mori, K.)

  16. Student Achievement Study, 1970-1974. The IEA Six-Subject Data Bank [machine-readable data file].

    Science.gov (United States)

    International Association for the Evaluation of Educational Achievement, Stockholm (Sweden).

    The "Student Achievement Study" machine-readable data files (MRDF) (also referred to as the "IEA Six-Subject Survey") are the result of an international data collection effort during 1970-1974 by 21 designated National Centers, which had agreed to cooperate. The countries involved were: Australia, Belgium, Chile, England-Wales,…

  17. Comparative Costs of Converting Shelf List Records to Machine Readable Form

    Directory of Open Access Journals (Sweden)

    Richard E. Chapin

    1968-03-01

    Full Text Available A study at Michigan State University Library compared the costs of three different methods of conversion: keypunching, paper-tape typewriting, and optical scanning by a service bureau. The record converted included call number, copy number, first 39 letters of the author's name, first 43 letters of the title, and date of publication. Source documents were all of the shelf list cards at the Library. The end products were a master book tape of the library collections and a machine readable book card for each volume to be used in an automated circulation system.

  18. USA - Postponement of Deadline for Machine-Readable Passports

    CERN Multimedia

    2003-01-01

    U.S. Secretary of State Colin Powell has granted a postponement until October 26, 2004, as the date by which travellers holding Swiss passports must present a machine-readable passport at a U.S. port of entry to be admitted to the country without a visa. As in the past, citizens of Switzerland and other visa waiver program countries are permitted to enter the United States for general business or tourist purposes for a maximum of 90 days without needing a visa. Other categories of travellers such as students, journalists, individuals employed in the U.S., and all individuals staying for more than 90 days still require a visa. The postponement granted by the Secretary of State applies to a total to the following countries: Australia - Austria - Denmark - Finland - France - Germany - Iceland - Ireland - Italy - Japan - Monaco - Netherlands - New Zealand - Norway - Portugal - San Marino - Singapore - Spain - Sweden - Switzerland - United Kingdom More information available: http://www.us-embassy.ch Your Carlson...

  19. Remote filter handling machine for Sizewell B

    International Nuclear Information System (INIS)

    Barker, D.

    1993-01-01

    Two Filter Handling machines (FHM) have been supplied to Nuclear Electric plc for use at Sizewell B Power Station. These machines have been designed and built following ALARP principles with the functional objective being to remove radioactive filter cartridges from a filter housing and replace them with clean filter cartridges. Operation of the machine is achieved by the prompt of each distinct task via an industrial computer or the prompt of a full cycle using the automatic mode. The design of the machine features many aspects demonstrating ALARP while keeping the machine simple, robust and easy to maintain. (author)

  20. Test of fuel handling machine for Monju in sodium

    International Nuclear Information System (INIS)

    Ishii, Yoichiro; Masuda, Yoichi; Kataoka, Hajime

    1980-01-01

    Various types of fuel handling machines were studied, and under-the-plug method of fuel exchange and the fuel handling machine of single turning plug, fixed arm type were selected for the prototype reactor ''Monju'', because the turning plug is relatively small, and the rate of operation, safety, operational ability, maintainability and reliability required for the reactor are satisfied, moreover, the extrapolation to the demonstration reactor was considered. Attention must be paid to the points that the fuel handling machine is very long and invisible from outside, and the smooth operation and endurance in sodium are required for it. The full mock-up testing facility of single turning plug, fixed arm type was installed in 1974, and the full mock-up test has been carried out since 1975 in Oarai. Fuel exchange is carried out at about 6 months intervals in Monju, and about 20 to 30% of core and blanket fuels are exchanged for about one month period. The functions required for the fuel handling machine for Monju, the outline of the testing facility, the schedule of the testing, the items of testing and the results, and the matters to be specially written are described. The full mock-up test in sodium has been carried out for 5 years, and the functions and the endurance have been proved sufficiently. (Kako, I.)

  1. Review of the Conceptual Design for In-Vessel Fuel Handling Machines in SFR

    International Nuclear Information System (INIS)

    Kim, S. H.; Koo, G. H.

    2012-01-01

    The main in-vessel fuel handling machines in sodium cooled fast reactor(SFR) are composed of the in-vessel transfer machine(IVTM) and the rotating plug. These machines perform the function to handle fuel assemblies inside the reactor core during the refueling time. The IVTM should be able to access all areas above the reactor core and the fuel transfer port which can discharge the fuel assembly by the rotation of the rotating plug. In the 600 MWe demonstration reactor, the conceptual design of the in-vessel fuel handling machines was carried out. As shown in Fig. 1, the invessel fuel handling machines of the demonstration reactor are the double rotating plug type. With reference to the given core configuration of the demonstration reactor, the arrangement design of the rotating plug was carried out by using the developed simulation program. At present, the conceptual design of SFR prototype reactor which has small capacity of about 100 MWe is being started. Thus, it is necessary the economical efficiency and the reliability of the in-vessel fuel handling machines are reviewed according to the reduction of the power capacity. In this study, the preliminary design concepts of the main invessel fuel handling machines according to the fuel handling type are compared. Also, the design characteristics for the driving mechanism of the IVTM in the demonstration reactor and the recovery concept from the malfunction are reviewed

  2. Man-machine cooperation in remote handling for fusion plants

    International Nuclear Information System (INIS)

    Leinemann, K.

    1984-01-01

    Man-machine cooperation in remote handling for fusion plants comprises cooperation for design of equipment and planning of procedures using a CAD system, and cooperation during operation of the equipment with computer aided telemanipulation systems (CAT). This concept is presently being implemented for support of slave positioning, camera tracking, and camera alignment in the KfK manipulator test facility. The pilot implementation will be used to test various man-machine interface layouts, and to establish a set of basic buildings blocks for future implementations of advanced remote handling control systems. (author)

  3. WWER NPPs fuel handling machine control system

    International Nuclear Information System (INIS)

    Mini, G.; Rossi, G.; Barabino, M.; Casalini, M.

    2001-01-01

    In order to increase the safety level of the fuel handling machine on WWER NPPs, Ansaldo Nucleare was asked to design and supply a new Control System. Two FHM Control System units have been already supplied for Temelin NPP and others supplies are in process for the Atommash company, which has in charge the supply of FHMs for NPPs located in Russia, Ukraine and China. The Fuel Handling Machine (FHM) Control System is an integrated system capable of a complete management of nuclear fuel assemblies. The computer-based system takes into account all the operational safety interlocks so that it is able to avoid incorrect and dangerous manoeuvres in the case of operator error. Control system design criteria, hardware and software architecture, and quality assurance control, are in accordance with the most recent international requirements and standards, and in particular for electromagnetic disturbance immunity demands and seismic compatibility. The hardware architecture of the control system is based on ABB INFI 90 system. The microprocessor-based ABB INFI 90 system incorporates and improves upon many of the time proven control capabilities of Bailey Network 90, validated over 14,000 installations world-wide. The control system complies all the former designed sensors and devices of the machine and markedly the angular position measurement sensors named 'selsyn' of Russian design. Nevertheless it is fully compatible with all the most recent sensors and devices currently available on the market (for ex. Multiturn absolute encoders). All control logic components were developed using standard INFI 90 Engineering Work Station, interconnecting blocks extracted from an extensive SAMA library by using a graphical approach (CAD) and allowing an easier intelligibility, more flexibility and updated and coherent documentation. The data acquisition system and the Man Machine Interface are implemented by ABB in co-operation with Ansaldo. The flexible and powerful software structure

  4. VVER NPPs fuel handling machine control system

    International Nuclear Information System (INIS)

    Mini, G.; Rossi, G.; Barabino, M.; Casalini, M.

    2002-01-01

    In order to increase the safety level of the fuel handling machine on WWER NPPs, Ansaldo Nucleare was asked to design and supply a new Control System. Two Fuel Handling Machine (FHM) Control System units have been already supplied for Temelin NPP and others supply are in process for the Atommash company, which has in charge the supply of FHMs for NPPs located in Russia, Ukraine and China.The computer-based system takes into account all the operational safety interlocks so that it is able to avoid incorrect and dangerous manoeuvres in the case of operator error. Control system design criteria, hardware and software architecture, and quality assurance control, are in accordance with the most recent international requirements and standards, and in particular for electromagnetic disturbance immunity demands and seismic compatibility. The hardware architecture of the control system is based on ABB INFI 90 system. The microprocessor-based ABB INFI 90 system incorporates and improves upon many of the time proven control capabilities of Bailey Network 90, validated over 14,000 installations world-wide.The control system complies all the former designed sensors and devices of the machine and markedly the angular position measurement sensors named 'selsyn' of Russian design. Nevertheless it is fully compatible with all the most recent sensors and devices currently available on the market (for ex. Multiturn absolute encoders).All control logic were developed using standard INFI 90 Engineering Work Station, interconnecting blocks extracted from an extensive SAMA library by using a graphical approach (CAD) and allowing and easier intelligibility, more flexibility and updated and coherent documentation. The data acquisition system and the Man Machine Interface are implemented by ABB in co-operation with Ansaldo. The flexible and powerful software structure of 1090 Work-stations (APMS - Advanced Plant Monitoring System, or Tenore NT) has been successfully used to interface the

  5. A Study of Readability of Texts in Bangla through Machine Learning Approaches

    Science.gov (United States)

    Sinha, Manjira; Basu, Anupam

    2016-01-01

    In this work, we have investigated text readability in Bangla language. Text readability is an indicator of the suitability of a given document with respect to a target reader group. Therefore, text readability has huge impact on educational content preparation. The advances in the field of natural language processing have enabled the automatic…

  6. A Perspective on Remote Handling Operations and Human Machine Interface for Remote Handling in Fusion

    International Nuclear Information System (INIS)

    Haist, B.; Hamilton, D.; Sanders, St.

    2006-01-01

    A large-scale fusion device presents many challenges to the remote handling operations team. This paper is based on unique operational experience at JET and gives a perspective on remote handling task development, logistics and resource management, as well as command, control and human-machine interface systems. Remote operations require an accurate perception of a dynamic environment, ideally providing the operators with the same unrestricted knowledge of the task scene as would be available if they were actually at the remote work location. Traditional camera based systems suffer from a limited number of viewpoints and also degrade quickly when exposed to high radiation. Virtual Reality and Augmented Reality software offer great assistance. The remote handling system required to maintain a tokamak requires a large number of different and complex pieces of equipment coordinating to perform a large array of tasks. The demands on the operator's skill in performing the tasks can escalate to a point where the efficiency and safety of operations are compromised. An operations guidance system designed to facilitate the planning, development, validation and execution of remote handling procedures is essential. Automatic planning of motion trajectories of remote handling equipment and the remote transfer of heavy loads will be routine and need to be reliable. This paper discusses the solutions developed at JET in these areas and also the trends in management and presentation of operational data as well as command, control and HMI technology development offering the potential to greatly assist remote handling in future fusion machines. (author)

  7. Conceptual design report for a Fusion Engineering Device sector-handling machine and movable manipulator system

    International Nuclear Information System (INIS)

    Watts, K.D.; Masson, L.S.; McPherson, R.S.

    1982-10-01

    Design requirements, trade studies, design descriptions, conceptual designs, and cost estimates have been completed for the Fusion Engineering Device sector handling machine, movable manipulator system, subcomponent handling machine, and limiter blade handling machine. This information will be used by the Fusion Engineering Design Center to begin to determine the cost and magnitude of the effort required to perform remote maintenance on the Fusion Engineering Device. The designs presented are by no means optimum, and the costs estimates are rough-order-of-magnitude

  8. Assessing the Readability of Medical Documents: A Ranking Approach.

    Science.gov (United States)

    Zheng, Jiaping; Yu, Hong

    2018-03-23

    The use of electronic health record (EHR) systems with patient engagement capabilities, including viewing, downloading, and transmitting health information, has recently grown tremendously. However, using these resources to engage patients in managing their own health remains challenging due to the complex and technical nature of the EHR narratives. Our objective was to develop a machine learning-based system to assess readability levels of complex documents such as EHR notes. We collected difficulty ratings of EHR notes and Wikipedia articles using crowdsourcing from 90 readers. We built a supervised model to assess readability based on relative orders of text difficulty using both surface text features and word embeddings. We evaluated system performance using the Kendall coefficient of concordance against human ratings. Our system achieved significantly higher concordance (.734) with human annotators than did a baseline using the Flesch-Kincaid Grade Level, a widely adopted readability formula (.531). The improvement was also consistent across different disease topics. This method's concordance with an individual human user's ratings was also higher than the concordance between different human annotators (.658). We explored methods to automatically assess the readability levels of clinical narratives. Our ranking-based system using simple textual features and easy-to-learn word embeddings outperformed a widely used readability formula. Our ranking-based method can predict relative difficulties of medical documents. It is not constrained to a predefined set of readability levels, a common design in many machine learning-based systems. Furthermore, the feature set does not rely on complex processing of the documents. One potential application of our readability ranking is personalization, allowing patients to better accommodate their own background knowledge. ©Jiaping Zheng, Hong Yu. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 23.03.2018.

  9. A Machine Learning Approach to Measurement of Text Readability for EFL Learners Using Various Linguistic Features

    Science.gov (United States)

    Kotani, Katsunori; Yoshimi, Takehiko; Isahara, Hitoshi

    2011-01-01

    The present paper introduces and evaluates a readability measurement method designed for learners of EFL (English as a foreign language). The proposed readability measurement method (a regression model) estimates the text readability based on linguistic features, such as lexical, syntactic and discourse features. Text readability refers to the…

  10. Improving readability through extractive summarization for learners with reading difficulties

    Directory of Open Access Journals (Sweden)

    K. Nandhini

    2013-11-01

    Full Text Available In this paper, we describe the design and evaluation of extractive summarization approach to assist the learners with reading difficulties. As existing summarization approaches inherently assign more weights to the important sentences, our approach predicts the summary sentences that are important as well as readable to the target audience with good accuracy. We used supervised machine learning technique for summary extraction of science and social subjects in the educational text. Various independent features from the existing literature for predicting important sentences and proposed learner dependent features for predicting readable sentences are extracted from texts and are used for automatic classification. We performed both extrinsic and intrinsic evaluation on this approach and the intrinsic evaluation is carried out using F-measure and readability analysis. The extrinsic evaluation comprises of learner feedback using likert scale and the effect of assistive summary on improving readability for learners’ with reading difficulty using ANOVA. The results show significant improvement in readability for the target audience using assistive summary.

  11. Fifth Fundamental Catalogue (FK5). Part 1: Basic fundamental stars (Fricke, Schwan, and Lederle 1988): Documentation for the machine-readable version

    Science.gov (United States)

    Warren, Wayne H., Jr.

    1990-01-01

    The machine-readable version of the catalog, as it is currently being distributed from the Astronomical Data Center, is described. The Basic FK5 provides improved mean positions and proper motions for the 1535 classical fundamental stars that had been included in the FK3 and FK4 catalogs. The machine version of the catalog contains the positions and proper motions of the Basic FK5 stars for the epochs and equinoxes J2000.0 and B1950.0, the mean epochs of individual observed right ascensions and declinations used to determine the final positions, and the mean errors of the final positions and proper motions for the reported epochs. The cross identifications to other designations used for the FK5 stars that are given in the published catalog were not included in the original machine versions, but the Durchmusterung numbers have been added at the Astronomical Data Center.

  12. Readability versus Leveling.

    Science.gov (United States)

    Fry, Edward

    2002-01-01

    Shows some similarities and differences between readability formulas and leveling procedures and reports some current large-scale uses of readability formulas. Presents a dictionary definition of readability and leveling, and a history and background of readability and leveling. Discusses what goes into determining readability and leveling scores.…

  13. Nuclear fuel handling apparatus

    International Nuclear Information System (INIS)

    Andrea, C.; Dupen, C.F.G.; Noyes, R.C.

    1977-01-01

    A fuel handling machine for a liquid metal cooled nuclear reactor in which a retractable handling tube and gripper are lowered into the reactor to withdraw a spent fuel assembly into the handling tube. The handling tube containing the fuel assembly immersed in liquid sodium is then withdrawn completely from the reactor into the outer barrel of the handling machine. The machine is then used to transport the spent fuel assembly directly to a remotely located decay tank. The fuel handling machine includes a decay heat removal system which continuously removes heat from the interior of the handling tube and which is capable of operating at its full cooling capacity at all times. The handling tube is supported in the machine from an articulated joint which enables it to readily align itself with the correct position in the core. An emergency sodium supply is carried directly by the machine to provide make up in the event of a loss of sodium from the handling tube during transport to the decay tank. 5 claims, 32 drawing figures

  14. Man/machine interface for a nuclear cask remote handling control station: system design requirements

    International Nuclear Information System (INIS)

    Clarke, M.M.; Kreifeldt, J.G.; Draper, J.V.

    1984-01-01

    Design requirements are presented for a control station of a proposed semi-automated facility for remote handling of nuclear waste casks. Functional and operational man/machine interface: controls, displays, software format, station architecture, and work environment. In addition, some input is given to the design of remote sensing systems in the cask handling areas. 18 references, 9 figures, 12 tables

  15. Cleaning, disassembly, and requalification of the FFTF in vessel handling machine

    International Nuclear Information System (INIS)

    Coops, W.J.

    1977-10-01

    The Engineering Model In Vessel Handling Machine (IVHM) was successfully removed, cleaned, disassembled, inspected, reassembled and reinstalled into the sodium test vessel at Richland, Washington. This was the first time in the United States a full size operational sodium wetted machine has been cleaned by the water vapor nitrogen process and requalified for operation. The work utilized an atmospheric control system during removal, a tank type water vapor nitrogen cleaning system and an open ''hands on'' disassembly and assembly stand. Results of the work indicate the tools, process and equipment are adequate for the non-radioactive maintenance sequence. Additionally, the work proves that a machine of this complexity can be successfully cleaned, maintained and re-used without the need to replace a large percentage of the sodium wetted parts

  16. The Principles of Readability

    Science.gov (United States)

    DuBay, William H.

    2004-01-01

    The principles of readability are in every style manual. Readability formulas are in every writing aid. What is missing is the research and theory on which they stand. This short review of readability research spans 100 years. The first part covers the history of adult literacy studies in the U.S., establishing the stratified nature of the adult…

  17. A Modular Framework for Transforming Structured Data into HTML with Machine-Readable Annotations

    Science.gov (United States)

    Patton, E. W.; West, P.; Rozell, E.; Zheng, J.

    2010-12-01

    There is a plethora of web-based Content Management Systems (CMS) available for maintaining projects and data, i.a. However, each system varies in its capabilities and often content is stored separately and accessed via non-uniform web interfaces. Moving from one CMS to another (e.g., MediaWiki to Drupal) can be cumbersome, especially if a large quantity of data must be adapted to the new system. To standardize the creation, display, management, and sharing of project information, we have assembled a framework that uses existing web technologies to transform data provided by any service that supports the SPARQL Protocol and RDF Query Language (SPARQL) queries into HTML fragments, allowing it to be embedded in any existing website. The framework utilizes a two-tier XML Stylesheet Transformation (XSLT) that uses existing ontologies (e.g., Friend-of-a-Friend, Dublin Core) to interpret query results and render them as HTML documents. These ontologies can be used in conjunction with custom ontologies suited to individual needs (e.g., domain-specific ontologies for describing data records). Furthermore, this transformation process encodes machine-readable annotations, namely, the Resource Description Framework in attributes (RDFa), into the resulting HTML, so that capable parsers and search engines can extract the relationships between entities (e.g, people, organizations, datasets). To facilitate editing of content, the framework provides a web-based form system, mapping each query to a dynamically generated form that can be used to modify and create entities, while keeping the native data store up-to-date. This open framework makes it easy to duplicate data across many different sites, allowing researchers to distribute their data in many different online forums. In this presentation we will outline the structure of queries and the stylesheets used to transform them, followed by a brief walkthrough that follows the data from storage to human- and machine-accessible web

  18. Machine-readable files developed for the High Plains Regional Aquifer-System analysis in parts of Colorado, Kansas, Nebraska, New Mexico, Oklahoma, South Dakota, Texas, and Wyoming

    Science.gov (United States)

    Ferrigno, C.F.

    1986-01-01

    Machine-readable files were developed for the High Plains Regional Aquifer-System Analysis project are stored on two magnetic tapes available from the U.S. Geological Survey. The first tape contains computer programs that were used to prepare, store, retrieve, organize, and preserve the areal interpretive data collected by the project staff. The second tape contains 134 data files that can be divided into five general classes: (1) Aquifer geometry data, (2) aquifer and water characteristics , (3) water levels, (4) climatological data, and (5) land use and water use data. (Author 's abstract)

  19. Methods to Measure Map Readability

    OpenAIRE

    Harrie, Lars

    2009-01-01

    Creation of maps in real-time web services introduces challenges concerning map readability. Therefore we must introduce analytical measures controlling the readability. The aim of this study is to develop and evaluate analytical readability measures with the help of user tests.

  20. Evaluating the Readability of Radio Frequency Identification for Construction Materials

    Directory of Open Access Journals (Sweden)

    Younghan Jung

    2017-01-01

    Full Text Available Radio Frequency Identification (RFID, which was originally introduced to improve material handling and speed production as part of supply chain management, has become a globally accepted technology that is now applied on many construction sites to facilitate real-time information visibility and traceability. This paper describes a senior undergraduate project for a Construction Management (CM program that was specifically designed to give the students a greater insight into technical research in the CM area. The students were asked to determine whether it would be possible to utilize an RFID system capable of tracking tagged equipment, personnel and materials across an entire construction site. This project required them to set up an experimental program, execute a series of experiments, analyze the results and summarize them in a report. The readability test was performed using an active Ultra-High frequency (UHF, 433.92 MHz RFID system with various construction materials, including metal, concrete, wood, plastic, and aluminum. The readability distance distances are measured for each of the six scenarios. The distance at which a tag was readable with no obstructions was found to be an average of 133.9m based on three measurements, with a standard deviation of 3.9m. This result confirms the manufacturer’s claimed distance of 137.2m. The RFID tag embedded under 50.8mm of concrete was readable for an average distance of only 12.2m, the shortest readable distance of any of the scenarios tested. At the end of the semester, faculty advisors held an open discussion session to gather feedback and elicit the students’ reflections on their research experiences, revealing that the students’ overall impressions of their undergraduate research had positively affected their postgraduate education plans.

  1. The Readability of an Unreadable Text.

    Science.gov (United States)

    Gordon, Robert M.

    1980-01-01

    The Dale-Chall Readability Formula and the Fry Readability Graph were used to analyze passages of Plato's "Parmenides," a notoriously difficult literary piece. The readability levels of the text ranged from fourth to eighth grade (Dale-Chall) and from sixth to tenth grade (Fry), indicating the limitations of the readability tests. (DF)

  2. Understanding and Writing G & M Code for CNC Machines

    Science.gov (United States)

    Loveland, Thomas

    2012-01-01

    In modern CAD and CAM manufacturing companies, engineers design parts for machines and consumable goods. Many of these parts are cut on CNC machines. Whether using a CNC lathe, milling machine, or router, the ideas and designs of engineers must be translated into a machine-readable form called G & M Code that can be used to cut parts to precise…

  3. A possible extension to the RInChI as a means of providing machine readable process data.

    Science.gov (United States)

    Jacob, Philipp-Maximilian; Lan, Tian; Goodman, Jonathan M; Lapkin, Alexei A

    2017-04-11

    The algorithmic, large-scale use and analysis of reaction databases such as Reaxys is currently hindered by the absence of widely adopted standards for publishing reaction data in machine readable formats. Crucial data such as yields of all products or stoichiometry are frequently not explicitly stated in the published papers and, hence, not reported in the database entry for those reactions, limiting their usefulness for algorithmic analysis. This paper presents a possible extension to the IUPAC RInChI standard via an auxiliary layer, termed ProcAuxInfo, which is a standardised, extensible form in which to report certain key reaction parameters such as declaration of all products and reactants as well as auxiliaries known in the reaction, reaction stoichiometry, amounts of substances used, conversion, yield and operating conditions. The standard is demonstrated via creation of the RInChI including the ProcAuxInfo layer based on three published reactions and demonstrates accurate data recoverability via reverse translation of the created strings. Implementation of this or another method of reporting process data by the publishing community would ensure that databases, such as Reaxys, would be able to abstract crucial data for big data analysis of their contents.

  4. Analyzing readability of medicines information material in Slovenia

    Science.gov (United States)

    Kasesnik, Karin; Kline, Mihael

    2011-01-01

    Objective: Readability has been claimed to be an important factor for understanding texts describing health symptoms and medications. Such texts may be a factor which indirectly affects the health of the population. Despite the expertise of physicians, the readability of information sources may be important for acquiring essential treatment information. The aim of this study was to measure the readability level of medicines promotion material in Slovenia. Methods: The Flesch readability formula was modified to comply with Slovene texts. On the basis of determining the Slovene readability algorithm, the readability ease related to the readability grade level of different Slovene texts was established. In order to estimate an adjustment of the texts to the recommended readability grade level of the targeted population, readability values of English texts were set. One sample t-test and standard deviations from the arithmetic mean values were used as statistical tests. Results: The results of the research showed low readability scores of the Slovene texts. Difficult readability values were seen in different types of examined texts: in patient information leaflets, in the summaries of product characteristics, in promotional materials, while describing over-the-counter medications and in the materials for creating disease awareness. Especially low readability values were found within the texts belonging to promotional materials intended for the physicians. None of researched items, not even for the general public, were close to primary school grade readability levels and therefore could not be described as easily readable. Conclusion: This study provides an understanding of the level of readability of selected Slovene medicines information material. It was concluded that health-related texts were not compliant with general public or with healthcare professional needs. PMID:23093886

  5. Readability of Invasive Procedure Consent Forms.

    Science.gov (United States)

    Eltorai, Adam E M; Naqvi, Syed S; Ghanian, Soha; Eberson, Craig P; Weiss, Arnold-Peter C; Born, Christopher T; Daniels, Alan H

    2015-12-01

    Informed consent is a pillar of ethical medicine which requires patients to fully comprehend relevant issues including the risks, benefits, and alternatives of an intervention. Given the average reading skill of US adults is at the 8th grade level, the American Medical Association (AMA) and the National Institutes of Health (NIH) recommend patient information materials should not exceed a 6th grade reading level. We hypothesized that text provided in invasive procedure consent forms would exceed recommended readability guidelines for medical information. To test this hypothesis, we gathered procedure consent forms from all surgical inpatient hospitals in the state of Rhode Island. For each consent form, readability analysis was measured with the following measures: Flesch Reading Ease Formula, Flesch-Kincaid Grade Level, Fog Scale, SMOG Index, Coleman-Liau Index, Automated Readability Index, and Linsear Write Formula. These readability scores were used to calculate a composite Text Readability Consensus Grade Level. Invasive procedure consent forms were found to be written at an average of 15th grade level (i.e., third year of college), which is significantly higher than the average US adult reading level of 8th grade (p readability guidelines for patient materials of 6th grade (p readability levels which makes comprehension difficult or impossible for many patients. Efforts to improve the readability of procedural consent forms should improve patient understanding regarding their healthcare decisions. © 2015 Wiley Periodicals, Inc.

  6. Emotioncy: A Potential Measure of Readability

    Science.gov (United States)

    Pishghadamn, Reza; Abbasnejad, Hannaheh

    2016-01-01

    Given the deficiencies of readability formulae as reliable tools for measuring text readability in educational settings, this study aims to offer a new measure to improve the current methods of testing the readability levels of texts through the incorporation of the newly-developed concept of emotioncy. To this end, a group of 221 students were…

  7. Fuel-handling machine tests at the Institute for Nuclear Research - Pitesti. Computer and software research and engineering

    International Nuclear Information System (INIS)

    Doca, Cezar; Predescu, Darie; Maiorescu, Oliviu; Dobrescu, Sorin

    2003-01-01

    This poster introduces the fuel-handling machine SCC-MID. This work is part of a very ambitious project that was accomplished with remarkable investment efforts. Material and human resources was spent to build a test stand for fuel handling machines (CANDU system), closely linked to NPP Cernavoda. A challenging goal was also to develop a computer system (hw/sw) designed and engineered to control the test and calibration process of this fuel-handling machine. The design takes care both of the functionality required to correctly control the F/H machine and of the additional functionality required to assist the testing process. How to test the system itself to validate the implemented solutions, how to safely and consistently maintain the data involved, how to manage such a system, how to gradually integrate the system in the whole stand saving time and work already done and solutions already validated were questions we had to find out right solutions. We choose modular solutions both for hardware and software, based on late technologies which in addition permit to achieve the versatility we needed, namely: VME based hw systems running OS9/68k (Unix like real-time multi-user multitasking OS), ISaGRAF (process control application oriented development and run-time software), Hawk (cross-compiler and IDE software for C/C++ software development intended to run on other Motorola based hw), Suretrack (project management software). The system topology implements open system network concepts that permit communication between different sw/hw platforms (OS9/Motorola and ix86/ms-windows based systems) We spent major resources to model the technological processes and test tools like: - real time simulation of the machine behavior while responding to the human commands or to the state changes of other machine parts as a result of other commands or as mechanical interlinks or technological interlocks and presentation of results revealing time related movements; - database

  8. Readability assessment of online ophthalmic patient information.

    Science.gov (United States)

    Edmunds, Matthew R; Barry, Robert J; Denniston, Alastair K

    2013-12-01

    Patients increasingly use the Internet to access information related to their disease, but poor health literacy is known to impact negatively on medical outcomes. Multiple agencies have recommended that patient-oriented literature be written at a fourth- to sixth-grade (9-12 years of age) reading level to assist understanding. The readability of online patient-oriented materials related to ophthalmic diagnoses is not yet known. To assess the readability of online literature specifically for a range of ophthalmic conditions. Body text of the top 10 patient-oriented websites for 16 different ophthalmic diagnoses, covering the full range of ophthalmic subspecialties, was analyzed for readability, source (United Kingdom vs non-United Kingdom, not for profit vs commercial), and appropriateness for sight-impaired readers. Four validated readability formulas were used: Flesch Reading Ease Score (FRES), Flesch-Kincaid Grade Level (FKGL), Simple Measure of Gobbledygook (SMOG), and Gunning Fog Index (GFOG). Data were compared with the Mann-Whitney test (for 2 groups) and Kruskal-Wallis test (for more than 2 groups) and correlation was assessed by the Spearman r. None of the 160 webpages had readability scores within published guidelines, with 83% assessed as being of "difficult" readability. Not-for-profit webpages were of significantly greater length than commercial webpages (P = .02) and UK-based webpages had slightly superior readability scores compared with those of non-UK webpages (P = .004 to P readability formula used). Of all webpages evaluated, only 34% included facility to adjust text size to assist visually impaired readers. To our knowledge, this is the first study to assess readability of patient-focused webpages specifically for a range of ophthalmic diagnoses. In keeping with previous studies in other medical conditions, we determined that readability scores were inferior to those recommended, irrespective of the measure used. Although readability is only one

  9. Testing of FFTF fuel handling equipment

    International Nuclear Information System (INIS)

    Coleman, D.W.; Grazzini, E.D.; Hill, L.F.

    1977-07-01

    The Fast Flux Test Facility has several manual/computer controlled fuel handling machines which are exposed to severe environments during plant operation but still must operate reliably when called upon for reactor refueling. The test programs for two such machines--the Closed Loop Ex-Vessel Machine and the In-Vessel Handling Machine--are described. The discussion centers on those areas where design corrections or equipment repairs substantiated the benefits of a test program prior to plant operation

  10. Concept design of divertor remote handling system for the FAST machine

    Energy Technology Data Exchange (ETDEWEB)

    Di Gironimo, G., E-mail: giuseppe.digironimo@unina.it [Association Euratom/ENEA/CREATE, Università di Napoli Federico II, 80125 Napoli (Italy); Labate, C.; Renno, F. [Association Euratom/ENEA/CREATE, Università di Napoli Federico II, 80125 Napoli (Italy); Brolatti, G.; Crescenzi, F.; Crisanti, F. [CR ENEA Frascati, Via E. Fermi 27, Frascati (RM) (Italy); Lanzotti, A. [Association Euratom/ENEA/CREATE, Università di Napoli Federico II, 80125 Napoli (Italy); Lucca, F. [LT Calcoli SaS, Piazza Prinetti 26/B, 23807 Merate (Italy); Siuko, M. [VTT Systems Engineering, Tekniikankatu 1, 33720 Tampere (Finland)

    2013-10-15

    The paper presents a concept design of a remote handling (RH) system oriented to maintenance operations on the divertor second cassette in FAST, a satellite of ITER tokamak. Starting from ITER configuration, a suitably scaled system, composed by a cassette multifunctional mover (CMM) connected to a second cassette end-effector (SCEE), can represent a very efficient solution for FAST machine. The presence of a further system able to open the divertor port, used for RH aims, and remove the first cassette, already aligned with the radial direction of the port, is presumed. Although an ITER-like system maintains essentially shape and proportions of its reference configuration, an appropriate arrangement with FAST environment is needed, taking into account new requirements due to different dimensions, weights and geometries. The use of virtual prototyping and the possibility to involve a great number of persons, not only mechanical designers but also physicist, plasma experts and personnel assigned to remote handling operations, made them to share the multiphysics design experience, according to a concurrent engineering approach. Nevertheless, according to the main objective of any satellite tokamak, such an approach benefits the study of enhancements to ITER RH system and the exploration of alternative solutions.

  11. Grammatical Metaphor, Controlled Languageand Machine Translation

    DEFF Research Database (Denmark)

    Møller, Margrethe

    2003-01-01

    It is a general assumption that 1) the readability and clarity of LSP texts written in a controlled language are better than uncontrolled texts and 2) that controlled languages produce better results with machine translation than uncontrolled languages. Controlled languages impose lexical...

  12. Simplifying the Reuse and Interoperability of Geoscience Data Sets and Models with Semantic Metadata that is Human-Readable and Machine-actionable

    Science.gov (United States)

    Peckham, S. D.

    2017-12-01

    Standardized, deep descriptions of digital resources (e.g. data sets, computational models, software tools and publications) make it possible to develop user-friendly software systems that assist scientists with the discovery and appropriate use of these resources. Semantic metadata makes it possible for machines to take actions on behalf of humans, such as automatically identifying the resources needed to solve a given problem, retrieving them and then automatically connecting them (despite their heterogeneity) into a functioning workflow. Standardized model metadata also helps model users to understand the important details that underpin computational models and to compare the capabilities of different models. These details include simplifying assumptions on the physics, governing equations and the numerical methods used to solve them, discretization of space (the grid) and time (the time-stepping scheme), state variables (input or output), model configuration parameters. This kind of metadata provides a "deep description" of a computational model that goes well beyond other types of metadata (e.g. author, purpose, scientific domain, programming language, digital rights, provenance, execution) and captures the science that underpins a model. A carefully constructed, unambiguous and rules-based schema to address this problem, called the Geoscience Standard Names ontology will be presented that utilizes Semantic Web best practices and technologies. It has also been designed to work across science domains and to be readable by both humans and machines.

  13. Integrated digital control and man-machine interface for complex remote handling systems

    International Nuclear Information System (INIS)

    Rowe, J.C.; Spille, R.F.; Zimmermann, S.D.

    1986-12-01

    The Advanced Integrated Maintenance System (AIMS) is part of a continuing effort within the Consolidated Fuel Reprocessing Program at Oak Ridge National Laboratory to develop and extend the capabilities of remote manipulation and maintenance technology. The AIMS is a totally integrated approach to remote handling in hazardous environments. State-of-the-art computer systems connected through a high-speed communication network provide a real-time distributed control system that supports the flexibility and expandability needed for large integrated maintenance applications. A Man-Machine Interface provides high-level human interaction through a powerful color graphics menu-controlled operator console. An auxiliary control system handles the real-time processing needs for a variety of support hardware. A pair of dedicated fiber-optic-linked master/slave computer system control the Advanced Servomanipulator master/slave arms using powerful distributed digital processing methods. The FORTH language was used as a real-time operating and development environment for the entire system, and all of these components are integrated into a control room concept that represents the latest advancements in the development of remote maintenance facilities for hazardous environments

  14. The Readability of Principles of Macroeconomics Textbooks

    Science.gov (United States)

    Tinkler, Sarah; Woods, James

    2013-01-01

    The authors evaluated principles of macroeconomics textbooks for readability using Coh-Metrix, a computational linguistics tool. Additionally, they conducted an experiment on Amazon's Mechanical Turk Web site in which participants ranked the readability of text samples. There was a wide range of scores on readability indexes both among…

  15. Readability Approaches: Implications for Turkey

    Science.gov (United States)

    Ulusoy, Mustafa

    2006-01-01

    Finding the right fit between students' reading ability and textbooks is very important for comprehension. Readability studies aim to analyse texts to find the right fit between students and texts. In this literature review, readability studies are classified under quantitative, qualitative and combined quantitative-qualitative readability…

  16. [Readability of surgical informed consent in Spain].

    Science.gov (United States)

    San Norberto, Enrique María; Gómez-Alonso, Daniel; Trigueros, José M; Quiroga, Jorge; Gualis, Javier; Vaquero, Carlos

    2014-03-01

    To assess the readability of informed consent documents (IC) of the different national surgical societies. During January 2012 we collected 504 IC protocols of different specialties. To calculate readability parameters the following criteria were assessed: number of words, syllables and phrases, syllables/word and word/phrase averages, Word correlation index, Flesch-Szigriszt index, Huerta Fernández index, Inflesz scale degree and the Gunning-Fog index. The mean Flesch-Szigriszt index was 50.65 ± 6,72, so readability is considered normal. There are significant differences between specialties such as Urology (43.00 ± 4.17) and Angiology and Vascular Surgery (63.00 ± 3.26, P<.001). No IC would be appropriate for adult readability according to the Fernández-Huerta index (total mean 55.77 ± 6.57); the IC of Angiology and Vascular Surgery were the closest ones (67.85 ± 3.20). Considering the Inflesz scale degree (total mean of 2.84 ± 3,23), IC can be described as «somewhat difficult». There are significant differences between the IC of Angiology and Vascular Surgery (3.23 ± 0.47) that could be qualified as normal, or Cardiovascular Surgery (2.79 ± 0.43) as «nearly normal readability»; and others such as Urology (1, 70 ± 0.46, P<.001) and Thoracic Surgery (1.90 ± 0.30, P<.001), with a readability between «very» and «somewhat» difficult. The Gunning-Fog indexes are far from the readability for a general audience (total mean of 26.29 ± 10,89). IC developed by scientific societies of different surgical specialties do not have an adequate readability for patients. We recommend the use of readability indexes during the writing of these consent forms. Copyright © 2012 AEC. Published by Elsevier Espana. All rights reserved.

  17. Readability assessment of online tracheostomy care resources.

    Science.gov (United States)

    Kong, Keonho Albert; Hu, Amanda

    2015-02-01

    To assess the readability of online tracheostomy care resources. Cross-sectional study. Academic center. A Google search was performed for "tracheostomy care" in January 2014. The top 50 results were categorized into major versus minor websites and patient-oriented versus professional-oriented resources. These websites were evaluated with the following readability tools: Flesch Reading Ease Score (FRES), Flesch-Kincaid Grade Level (FKGL), Simple Measure of Gobbledygook (SMOG), and Gunning Frequency of Gobbledygook (GFOG). Readability scores for the websites were FRES 57.21 ± 16.71 (possible range = 0-100), FKGL 8.33 ± 2.84 (possible range = 3-12), SMOG 11.25 ± 2.49 (possible range = 3-19), and GFOG 11.43 ± 4.07 (possible range = 3-19). There was no significant difference in all 4 readability scores between major (n = 41) and minor (n = 9) websites. Professional-oriented websites (n = 19) had the following readability scores: FRES 40.77 ± 11.69, FKGL 10.93 ± 2.48, SMOG 13.29 ± 2.32, and GFOG 14.91 ± 3.98. Patient-oriented websites (n = 31) had the following readability scores: FRES 67.29 ± 9.91, FKGL 6.73 ± 1.61, SMOG 10.01 ± 1.64, and GFOG 9.30 ± 2.27. Professional-oriented websites had more difficult readability scores than patient-oriented websites for FRES (P readability between major and minor websites. Professional-oriented websites were more difficult to read than patient-oriented websites. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.

  18. The readability of American Academy of Pediatrics patient education brochures.

    Science.gov (United States)

    Freda, Margaret Comerford

    2005-01-01

    The purpose of this study was to evaluate the readability of American Academy of Pediatrics (AAP) patient education brochures. Seventy-four brochures were analyzed using two readability formulas. Mean readability for all 74 brochures was grade 7.94 using the Flesch-Kincaid formula, and grade 10.1 with SMOG formula (P = .001). Using the SMOG formula, no brochures were of acceptably low (education brochures have acceptably low levels of readability, but at least half are written at higher than acceptable readability levels for the general public. This study also demonstrated statistically significant variability between the two different readability formulas; had only the SMOG formula been used, all of the brochures would have had unacceptably high readability levels. Readability is an essential concept for patient education materials. Professional associations that develop and market patient education materials should test for readability and publish those readability levels on each piece of patient education so health care providers will know if the materials are appropriate for their patients.

  19. Determining Readability: How to Select and Apply Easy-to-Use Readability Formulas to Assess the Difficulty of Adult Literacy Materials

    Science.gov (United States)

    Burke, Victoria; Greenberg, Daphne

    2010-01-01

    There are many readability tools that instructors can use to help adult learners select reading materials. We describe and compare different types of readability tools: formulas calculated by hand, tools found on the Web, tools embedded in a word processing program, and readability tools found in a commercial software program. Practitioners do not…

  20. As-Built Verification Plan Spent Nuclear Fuel Canister Storage Building MCO Handling Machine

    International Nuclear Information System (INIS)

    SWENSON, C.E.

    2000-01-01

    This as-built verification plan outlines the methodology and responsibilities that will be implemented during the as-built field verification activity for the Canister Storage Building (CSB) MCO HANDLING MACHINE (MHM). This as-built verification plan covers THE ELECTRICAL PORTION of the CONSTRUCTION PERFORMED BY POWER CITY UNDER CONTRACT TO MOWAT. The as-built verifications will be performed in accordance Administrative Procedure AP 6-012-00, Spent Nuclear Fuel Project As-Built Verification Plan Development Process, revision I. The results of the verification walkdown will be documented in a verification walkdown completion package, approved by the Design Authority (DA), and maintained in the CSB project files

  1. Readability of Online Materials for Rhinoplasty.

    Science.gov (United States)

    Santos, Pauline Joy F; Daar, David A; Paydar, Keyianoosh Z; Wirth, Garrett A

    2018-01-01

    Rhinoplasty is a popular aesthetic and reconstructive surgical procedure. However, little is known about the content and readability of online materials for patient education. The recommended grade level for educational materials is 7th to 8th grade according to the National Institutes of Health (NIH). This study aims to assess the readability of online patient resources for rhinoplasty. The largest public search engine, Google, was queried using the term "rhinoplasty" on February 26, 2016. Location filters were disabled and sponsored results excluded to avoid any inadvertent search bias. The 10 most popular websites were identified and all relevant, patient-directed information within one click from the original site was downloaded and saved as plain text. Readability was analyzed using five established analyses (Readability-score.com, Added Bytes, Ltd., Sussex, UK). Analysis of ten websites demonstrates an average grade level of at least 12 th grade. No material was at the recommended 7 th to 8 th grade reading level (Flesch-Kincaid, 11.1; Gunning-Fog, 14.1; Coleman-Liau, 14.5; SMOG 10.4; Automated Readability, 10.7; Average Grade Level, 12.2). Overall Flesch-Kincaid Reading Ease Index was 43.5, which is rated as "difficult." Online materials available for rhinoplasty exceed NIH-recommended reading levels, which may prevent appropriate decision-making in patients considering these types of surgery. Outcomes of this study identify that Plastic Surgeons should be cognizant of available online patient materials and make efforts to develop and provide more appropriate materials. Readability results can also contribute to marketing strategy and attracting a more widespread interest in the procedure.

  2. Evaluating four readability formulas for Afrikaans.

    NARCIS (Netherlands)

    Jansen, C. J. M.; Richards, Rose; Van Zyl, Liezl

    2017-01-01

    For almost a hundred years now, readability formulas have been used to measure how difficult it is to comprehend a given text. To date, four readability formulas have been developed for Afrikaans. Two such formulas were published by Van Rooyen (1986), one formula by McDermid Heyns (2007) and one

  3. Readability of Online Health Information: A Meta-Narrative Systematic Review.

    Science.gov (United States)

    Daraz, Lubna; Morrow, Allison S; Ponce, Oscar J; Farah, Wigdan; Katabi, Abdulrahman; Majzoub, Abdul; Seisa, Mohamed O; Benkhadra, Raed; Alsawas, Mouaz; Larry, Prokop; Murad, M Hassan

    2018-01-01

    Online health information should meet the reading level for the general public (set at sixth-grade level). Readability is a key requirement for information to be helpful and improve quality of care. The authors conducted a systematic review to evaluate the readability of online health information in the United States and Canada. Out of 3743 references, the authors included 157 cross-sectional studies evaluating 7891 websites using 13 readability scales. The mean readability grade level across websites ranged from grade 10 to 15 based on the different scales. Stratification by specialty, health condition, and type of organization producing information revealed the same findings. In conclusion, online health information in the United States and Canada has a readability level that is inappropriate for general public use. Poor readability can lead to misinformation and may have a detrimental effect on health. Efforts are needed to improve readability and the content of online health information.

  4. Readability and Understandability of Online Vocal Cord Paralysis Materials.

    Science.gov (United States)

    Balakrishnan, Vini; Chandy, Zachariah; Hseih, Amy; Bui, Thanh-Lan; Verma, Sunil P

    2016-03-01

    Patients use several online resources to learn about vocal cord paralysis (VCP). The objective of this study was to assess the readability and understandability of online VCP patient education materials (PEMs), with readability assessments and the Patient Education Materials Evaluation Tool (PEMAT), respectively. The relationship between readability and understandability was then analyzed. Descriptive and correlational design. Online PEMs were identified by performing a Google search with the term "vocal cord paralysis." After scientific webpages, news articles, and information for medical professionals were excluded, 29 articles from the first 50 search results were considered. Readability analysis was performed with 6 formulas. Four individuals with different educational backgrounds conducted understandability analysis with the PEMAT. Fleiss's Kappa interrater reliability analysis determined consistency among raters. Correlation between readability and understandability was determined with Pearson's correlation test. The reading level of the reviewed articles ranged from grades 9 to 17. Understandability ranged from 29% to 82%. Correlation analysis demonstrated a strong negative correlation between materials' readability and understandability (r = -0.462, P Online PEMs pertaining to VCP are written above the recommended reading levels. Overall, materials written at lower grade levels are more understandable. However, articles of identical grade levels had varying levels of understandability. The PEMAT may provide a more critical evaluation of the quality of a PEM when compared with readability formulas. Both readability and understandability should be used to evaluate PEMs. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  5. Readability of websites containing information on dental implants.

    Science.gov (United States)

    Jayaratne, Yasas S N; Anderson, Nina K; Zwahlen, Roger A

    2014-12-01

    It is recommended that health-related materials for patients be written at sixth grade level or below. Many websites oriented toward patient education about dental implants are available, but the readability of these sites has not been evaluated. To assess readability of patient-oriented online information on dental implants. Websites containing patient-oriented information on dental implants were retrieved using the Google search engine. Individual and mean readability/grade levels were calculated using standardized formulas. Readability of each website was classified as easy (≤ 6th-grade level) or difficult (≥ 10th grade level). Thirty nine websites with patient-oriented information on dental implant were found. The average readability grade level of these websites was 11.65 ± 1.36. No website scored at/below the recommended 6th grade level. Thirty four of 39 websites (87.18%) were difficult to read. The number of characters, words, and sentences on these sites varied widely. All patient-oriented websites on dental implants scored above the recommended grade level, and majority of these sites were "difficult" in their readability. There is a dire need to create patient information websites on implants, which the majority can read. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Quality and readability of English-language internet information for aphasia.

    Science.gov (United States)

    Azios, Jamie H; Bellon-Harn, Monica; Dockens, Ashley L; Manchaiah, Vinaya

    2017-08-14

    Little is known about the quality and readability of treatment information in specific neurogenic disorders, such as aphasia. The purpose of this study was to assess quality and readability of English-language Internet information available for aphasia treatment. Forty-three aphasia treatment websites were aggregated using five different country-specific search engines. Websites were then analysed using quality and readability assessments. Statistical calculations were employed to examine website ratings, differences between website origin and quality and readability scores, and correlations between readability instruments. Websites exhibited low quality with few websites obtaining Health On the Net (HON) certification or clear, thorough information as measured by the DISCERN. Regardless of website origin, readability scores were also poor. Approximate educational levels required to comprehend information on aphasia treatment websites ranged from 13 to 16 years of education. Significant differences were found between website origin and readability measures with higher levels of education required to understand information on websites of non-profit organisations. Current aphasia treatment websites were found to exhibit low levels of quality and readability, creating potential accessibility problems for people with aphasia and significant others. Websites including treatment information for aphasia must be improved in order to increase greater information accessibility.

  7. Readability of medicinal package leaflets: a systematic review.

    Science.gov (United States)

    Pires, Carla; Vigário, Marina; Cavaco, Afonso

    2015-01-01

    OBJECTIVE To review studies on the readability of package leaflets of medicinal products for human use. METHODS We conducted a systematic literature review between 2008 and 2013 using the keywords "Readability and Package Leaflet" and "Readability and Package Insert" in the academic search engine Biblioteca do Conhecimento Online, comprising different bibliographic resources/databases. The preferred reporting items for systematic reviews and meta-analyses criteria were applied to prepare the draft of the report. Quantitative and qualitative original studies were included. Opinion or review studies not written in English, Portuguese, Italian, French, or Spanish were excluded. RESULTS We identified 202 studies, of which 180 were excluded and 22 were enrolled [two enrolling healthcare professionals, 10 enrolling other type of participants (including patients), three focused on adverse reactions, and 7 descriptive studies]. The package leaflets presented various readability problems, such as complex and difficult to understand texts, small font size, or few illustrations. The main methods to assess the readability of the package leaflet were usability tests or legibility formulae. Limitations with these methods included reduced number of participants; lack of readability formulas specifically validated for specific languages (e.g., Portuguese); and absence of an assessment on patients literacy, health knowledge, cognitive skills, levels of satisfaction, and opinions. CONCLUSIONS Overall, the package leaflets presented various readability problems. In this review, some methodological limitations were identified, including the participation of a limited number of patients and healthcare professionals, the absence of prior assessments of participant literacy, humor or sense of satisfaction, or the predominance of studies not based on role-plays about the use of medicines. These limitations should be avoided in future studies and be considered when interpreting the results.

  8. Machine Learning Method Applied in Readout System of Superheated Droplet Detector

    Science.gov (United States)

    Liu, Yi; Sullivan, Clair Julia; d'Errico, Francesco

    2017-07-01

    Direct readability is one advantage of superheated droplet detectors in neutron dosimetry. Utilizing such a distinct characteristic, an imaging readout system analyzes image of the detector for neutron dose readout. To improve the accuracy and precision of algorithms in the imaging readout system, machine learning algorithms were developed. Deep learning neural network and support vector machine algorithms are applied and compared with generally used Hough transform and curvature analysis methods. The machine learning methods showed a much higher accuracy and better precision in recognizing circular gas bubbles.

  9. Sustainable machining

    CERN Document Server

    2017-01-01

    This book provides an overview on current sustainable machining. Its chapters cover the concept in economic, social and environmental dimensions. It provides the reader with proper ways to handle several pollutants produced during the machining process. The book is useful on both undergraduate and postgraduate levels and it is of interest to all those working with manufacturing and machining technology.

  10. Readability of the written study information in pediatric research in France.

    Directory of Open Access Journals (Sweden)

    Véronique Ménoni

    Full Text Available BACKGROUND: The aim was to evaluate the readability of research information leaflets (RIL for minors asked to participate in biomedical research studies and to assess the factors influencing this readability. METHODS AND FINDINGS: All the pediatric protocols from three French pediatric clinical research units were included (N = 104. Three criteria were used to evaluate readability: length of the text, Flesch's readability score and presence of illustrations. We compared the readability of RIL to texts specifically written for children (school textbooks, school exams or extracts from literary works. We assessed the effect of protocol characteristics on readability. The RIL had a median length of 608 words [350 words, 25(th percentile; 1005 words, 75(th percentile], corresponding to two pages. The readability of the RIL, with a median Flesch score of 40 [30; 47], was much poorer than that of pediatric reference texts, with a Flesch score of 67 [60; 73]. A small proportion of RIL (13/91; 14% were illustrated. The RIL were longer (p<0.001, more readable (p<0.001 and more likely to be illustrated (p<0.009 for industrial than for institutional sponsors. CONCLUSION: Researchers should routinely compute the reading ease of study information sheets and make greater efforts to improve the readability of written documents for potential participants.

  11. Machine assembly with a new material handling mechanism in the sewing machine

    Directory of Open Access Journals (Sweden)

    Umarova Z.M.

    2017-05-01

    Full Text Available the paper presents the dynamic model of the machine assembly with a recommended mechanism for moving material and the definition of the law of rails motion under various system parameters. The author has suggested the solution implemented by the system of differential equations numerically on the PC and the system describing the motion of the machine set. Recommended values ​​of the parameters of elastic links of material transfer mechanism have been obtained. The researcher has developed the methods of kinematic and dynamic analysis of the material transfer mechanism with elastic elements of the sewing machine and has approved the parameters and development of the design.

  12. Readability of Wikipedia

    NARCIS (Netherlands)

    Lucassen, T.; Dijkstra, Roald; Schraagen, Johannes Martinus Cornelis

    2012-01-01

    Wikipedia is becoming widely acknowledged as a reliable source of encyclopedic information. However, concerns have been expressed about its readability. Wikipedia articles might be written in a language too difficult to be understood by most of its visitors. In this study, we apply the Flesch

  13. FEMA and RAM Analysis for the Multi Canister Overpack (MCO) Handling Machine

    International Nuclear Information System (INIS)

    SWENSON, C.E.

    2000-01-01

    The Failure Modes and Effects Analysis and the Reliability, Availability, and Maintainability Analysis performed for the Multi-Canister Overpack Handling Machine (MHM) has shown that the current design provides for a safe system, but the reliability of the system (primarily due to the complexity of the interlocks and permissive controls) is relatively low. No specific failure modes were identified where significant consequences to the public occurred, or where significant impact to nearby workers should be expected. The overall reliability calculation for the MHM shows a 98.1 percent probability of operating for eight hours without failure, and an availability of the MHM of 90 percent. The majority of the reliability issues are found in the interlocks and controls. The availability of appropriate spare parts and maintenance personnel, coupled with well written operating procedures, will play a more important role in successful mission completion for the MHM than other less complicated systems

  14. ClearTK 2.0: Design Patterns for Machine Learning in UIMA.

    Science.gov (United States)

    Bethard, Steven; Ogren, Philip; Becker, Lee

    2014-05-01

    ClearTK adds machine learning functionality to the UIMA framework, providing wrappers to popular machine learning libraries, a rich feature extraction library that works across different classifiers, and utilities for applying and evaluating machine learning models. Since its inception in 2008, ClearTK has evolved in response to feedback from developers and the community. This evolution has followed a number of important design principles including: conceptually simple annotator interfaces, readable pipeline descriptions, minimal collection readers, type system agnostic code, modules organized for ease of import, and assisting user comprehension of the complex UIMA framework.

  15. Text Readability and Intuitive Simplification: A Comparison of Readability Formulas

    Science.gov (United States)

    Crossley, Scott A.; Allen, David B.; McNamara, Danielle S.

    2011-01-01

    Texts are routinely simplified for language learners with authors relying on a variety of approaches and materials to assist them in making the texts more comprehensible. Readability measures are one such tool that authors can use when evaluating text comprehensibility. This study compares the Coh-Metrix Second Language (L2) Reading Index, a…

  16. Readability of Online Patient Education Materials From the AAOS Web Site

    Science.gov (United States)

    Badarudeen, Sameer; Unes Kunju, Shebna

    2008-01-01

    One of the goals of the American Academy of Orthopaedic Surgeons (AAOS) is to disseminate patient education materials that suit the readability skills of the patient population. According to standard guidelines from healthcare organizations, the readability of patient education materials should be no higher than the sixth-grade level. We hypothesized the readability level of patient education materials available on the AAOS Web site would be higher than the recommended grade level, regardless when the material was available online. Readability scores of all articles from the AAOS Internet-based patient information Web site, “Your Orthopaedic Connection,” were determined using the Flesch-Kincaid grade formula. The mean Flesch-Kincaid grade level of the 426 unique articles was 10.43. Only 10 (2%) of the articles had the recommended readability level of sixth grade or lower. The readability of the articles did not change with time. Our findings suggest the majority of the patient education materials available on the AAOS Web site had readability scores that may be too difficult for comprehension by a substantial portion of the patient population. PMID:18324452

  17. Laser readable thermoluminescent radiation dosimeters and methods for producing thereof

    International Nuclear Information System (INIS)

    Braunlich, P.F.; Tetzlaff, W.

    1989-01-01

    Thin layer thermoluminescent radiation dosimeters for use in laser readable dosimetry systems, and methods of fabricating such thin layer dosimeters are disclosed. The thin layer thermoluminescent radiation dosimeters include a thin substrate made from glass or other inorganic materials capable of withstanding high temperatures and high heating rates. A thin layer of a thermoluminescent phosphor material is heat bonded to the substrate using an inorganic binder such as glass. The dosimeters can be mounted in frames and cases for ease in handling. Methods of the invention include mixing a suitable phosphor composition and binder, both being in particulate or granular form. The mixture is then deposited onto a substrate such as by using mask printing techniques. The dosimeters are thereafter heated to fuse and bond the binder and phosphor to the substrate. 34 figs

  18. Readability, content, and quality of online patient education materials on preeclampsia.

    Science.gov (United States)

    Lange, Elizabeth M S; Shah, Anuj M; Braithwaite, Brian A; You, Whitney B; Wong, Cynthia A; Grobman, William A; Toledo, Paloma

    2015-01-01

    The objective of this study was to evaluate the readability, content, and quality of patient education materials addressing preeclampsia. Websites of U.S. obstetrics and gynecology residency programs were searched for patient education materials. Readability, content, and quality were assessed. A one-sample t-test was used to evaluate mean readability level compared with the recommended 6th grade reading level. Mean readability levels were higher using all indices (p education materials should be improved.

  19. SRV-automatic handling device

    International Nuclear Information System (INIS)

    Yamada, Koji

    1987-01-01

    Automatic handling device for the steam relief valves (SRV's) is developed in order to achieve a decrease in exposure of workers, increase in availability factor, improvement in reliability, improvement in safety of operation, and labor saving. A survey is made during a periodical inspection to examine the actual SVR handling operation. An SRV automatic handling device consists of four components: conveyor, armed conveyor, lifting machine, and control/monitoring system. The conveyor is so designed that the existing I-rail installed in the containment vessel can be used without any modification. This is employed for conveying an SRV along the rail. The armed conveyor, designed for a box rail, is used for an SRV installed away from the rail. By using the lifting machine, an SRV installed away from the I-rail is brought to a spot just below the rail so that the SRV can be transferred by the conveyor. The control/monitoring system consists of a control computer, operation panel, TV monitor and annunciator. The SRV handling device is operated by remote control from a control room. A trial equipment is constructed and performance/function testing is carried out using actual SRV's. As a result, is it shown that the SRV handling device requires only two operators to serve satisfactorily. The required time for removal and replacement of one SRV is about 10 minutes. (Nogami, K.)

  20. Readability of Malaria Medicine Information Leaflets in Nigeria ...

    African Journals Online (AJOL)

    Purpose: To assess the readability of malaria medicines information leaflets available in Nigeria. Methods: Fourty five leaflets were assessed using the Simplified Measure of Gobbledygook (SMOG) readability test and by examining them for paper type, font size type, use of symbols and pictograms, and bilingual information ...

  1. Micro manipulators to handle micro machines. ; Aiming at developing clever and deft robots. Micro machine wo handling surutameno micro manipulator. ; Kashikoku kiyo na robot kaihatsu wo mezashite

    Energy Technology Data Exchange (ETDEWEB)

    Fujie, M [Hitachi, Ltd., Tokyo (Japan)

    1991-11-15

    The current state of micro manipulators (MM) to control micro machines is described. No MM can be realized with the conventional robots of which finger positions and attitudes are controlled by information on angles of each articulate. To solve this problem, such a system using the conception called a master slave manipulator with complex structure is proposed, in which human ways of manipulation are coupled with master arms with simple structure and slave arms facilitating works via a computer. The MM requires a flexible articulate chaining mechanism when the considerations on smallness of the arm structure and chaining of the multiple actuators are taken. To control the relative positions and attitudes, development of the control algorithm is required, which can learn the command signals given to a large number of actuators to drive mechanisms with ultra high freedoms and the relationship among changes in the end effector movements, rotation and directions, and can perform works according to precise relative positioning of objects to be handled. 8 refs., 4 figs.

  2. Readability Assessment of Online Patient Abdominoplasty Resources.

    Science.gov (United States)

    Phillips, Nicole A; Vargas, Christina R; Chuang, Danielle J; Lee, Bernard T

    2015-02-01

    Limited functional health literacy is recognized as an important contributor to health disparities in the United States. As internet access becomes more universal, there is increasing concern about whether patients with poor or marginal literacy can access understandable healthcare information. As such, the National Institutes of Health and American Medical Association recommend that patient information be written at a sixth grade level. This study identifies the most popular online resources for patient information about abdominoplasty and evaluates their readability in the context of average American literacy. The two largest internet search engines were queried for "tummy tuck surgery" to simulate a patient search in lay terms. The ten most popular sites common to both search engines were identified, and all relevant articles from the main sites were downloaded. Sponsored results were excluded. Readability analysis of the articles was performed using ten established tests. Online information about abdominoplasty from the ten most popular publically available websites had an overall average readability of 12th grade. Mean reading grade level scores among tests were: Coleman-Liau 11.9, Flesch-Kincaid 11.4, FORCAST 11.1, Fry 13, Gunning Fog 13.5, New Dale-Chall 11.8, New Fog Count 9.9, Raygor Estimate 12, and SMOG 13.4; Flesch Reading Ease index score was 46. Online patient resources about abdominoplasty are uniformly above the recommended target readability level and are likely too difficult for many patients to understand. A range of readability identified among websites could allow surgeons to guide patients to more appropriate resources for their literacy skills.

  3. Readability of pediatric health materials for preventive dental care

    Directory of Open Access Journals (Sweden)

    Riedy Christine A

    2006-11-01

    Full Text Available Abstract Background This study examined the content and general readability of pediatric oral health education materials for parents of young children. Methods Twenty-seven pediatric oral health pamphlets or brochures from commercial, government, industry, and private nonprofit sources were analyzed for general readability ("usability" according to several parameters: readability, (Flesch-Kincaid grade level, Flesch Reading Ease, and SMOG grade level; thoroughness, (inclusion of topics important to young childrens' oral health; textual framework (frequency of complex phrases, use of pictures, diagrams, and bulleted text within materials; and terminology (frequency of difficult words and dental jargon. Results Readability of the written texts ranged from 2nd to 9th grade. The average Flesch-Kincaid grade level for government publications was equivalent to a grade 4 reading level (4.73, range, 2.4 – 6.6; F-K grade levels for commercial publications averaged 8.1 (range, 6.9 – 8.9; and industry published materials read at an average Flesch-Kincaid grade level of 7.4 (range, 4.7 – 9.3. SMOG readability analysis, based on a count of polysyllabic words, consistently rated materials 2 to 3 grade levels higher than did the Flesch-Kincaid analysis. Government sources were significantly lower compared to commercial and industry sources for Flesch-Kincaid grade level and SMOG readability analysis. Content analysis found materials from commercial and industry sources more complex than government-sponsored publications, whereas commercial sources were more thorough in coverage of pediatric oral health topics. Different materials frequently contained conflicting information. Conclusion Pediatric oral health care materials are readily available, yet their quality and readability vary widely. In general, government publications are more readable than their commercial and industry counterparts. The criteria for usability and results of the analyses

  4. Improving readability of informed consents for research at an academic medical institution.

    Science.gov (United States)

    Hadden, Kristie B; Prince, Latrina Y; Moore, Tina D; James, Laura P; Holland, Jennifer R; Trudeau, Christopher R

    2017-12-01

    The final rule for the protection of human subjects requires that informed consent be "in language understandable to the subject" and mandates that "the informed consent must be organized in such a way that facilitates comprehension." This study assessed the readability of Institutional Review Board-approved informed consent forms at our institution, implemented an intervention to improve the readability of consent forms, and measured the first year impact of the intervention. Readability assessment was conducted on a sample of 217 Institutional Review Board-approved informed consents from 2013 to 2015. A plain language informed consent template was developed and implemented and readability was assessed again after 1 year. The mean readability of the baseline sample was 10th grade. The mean readability of the post-intervention sample (n=82) was seventh grade. Providing investigators with a plain language informed consent template and training can promote improved readability of informed consents for research.

  5. The readability of psychosocial wellness patient resources: improving surgical outcomes.

    Science.gov (United States)

    Kugar, Meredith A; Cohen, Adam C; Wooden, William; Tholpady, Sunil S; Chu, Michael W

    2017-10-01

    Patient education is increasingly accessed with online resources and is essential for patient satisfaction and clinical outcomes. The average American adult reads at a seventh grade level, and the National Institute of Health (NIH) and the American Medical Association (AMA) recommend that information be written at a sixth-grade reading level. Health literacy plays an important role in the disease course and outcomes of all patients, including those with depression and likely other psychiatric disorders, although this is an area in need of further study. The purpose of this study was to collect and analyze written, online mental health resources on the Veterans Health Administration (VA) website, and other websites, using readability assessment instruments. An internet search was performed to identify written patient education information regarding mental health from the VA (the VA Mental Health Website) and top-rated psychiatric hospitals. Seven mental health topics were included in the analysis: generalized anxiety disorder, bipolar, major depressive disorder, posttraumatic stress disorder, schizophrenia, substance abuse, and suicide. Readability analyses were performed using the Gunning Fog Index, the Flesch-Kincaid Grade Level, the Coleman-Liau Index, the SMOG Readability Formula, and the Automated Readability Index. These scores were then combined into a Readability Consensus score. A two-tailed t-test was used to compare the mean values, and statistical significance was set at P readability consensus than six of the top psychiatric hospitals (P readability consensus for mental health information on all websites analyzed was 9.52. Online resources for mental health disorders are more complex than recommended by the NIH and AMA. Efforts to improve readability of mental health and psychosocial wellness resources could benefit patient understanding and outcomes, especially in patients with lower literacy. Surgical outcomes are correlated with patient mental

  6. Development of the Simulation Program for the In-Vessel Fuel Handling System of Double Rotating Plug Type

    International Nuclear Information System (INIS)

    Kim, S. H.; Kim, J. B.

    2011-01-01

    In-vessel fuel handling machines are the main equipment of the in-vessel fuel handling system, which can move the core assembly inside the reactor vessel along with the rotating plug during refueling. The in vessel fuel handling machines for an advanced sodium cooled fast reactor(SFR) demonstration plant are composed of a direct lift machine(DM) and a fixed arm machine(FM). These machines should be able to access all areas above the reactor core by means of the rotating combination of double rotating plugs. Thus, in the in vessel fuel handling system of the double rotating plug type, it is necessary to decide the rotating plug size and evaluate the accessibility of in-vessel fuel handling machines in given core configuration. In this study, the simulation program based on LABVIEW which can effectively perform the arrangement design of the in vessel fuel handling system and simulate the rotating plug motion was developed. Fig. 1 shows the flow chart of the simulation program

  7. Assessing readability formula differences with written health information materials: application, results, and recommendations.

    Science.gov (United States)

    Wang, Lih-Wern; Miller, Michael J; Schmitt, Michael R; Wen, Frances K

    2013-01-01

    Readability formulas are often used to guide the development and evaluation of literacy-sensitive written health information. However, readability formula results may vary considerably as a result of differences in software processing algorithms and how each formula is applied. These variations complicate interpretations of reading grade level estimates, particularly without a uniform guideline for applying and interpreting readability formulas. This research sought to (1) identify commonly used readability formulas reported in the health care literature, (2) demonstrate the use of the most commonly used readability formulas on written health information, (3) compare and contrast the differences when applying common readability formulas to identical selections of written health information, and (4) provide recommendations for choosing an appropriate readability formula for written health-related materials to optimize their use. A literature search was conducted to identify the most commonly used readability formulas in health care literature. Each of the identified formulas was subsequently applied to word samples from 15 unique examples of written health information about the topic of depression and its treatment. Readability estimates from common readability formulas were compared based on text sample size, selection, formatting, software type, and/or hand calculations. Recommendations for their use were provided. The Flesch-Kincaid formula was most commonly used (57.42%). Readability formulas demonstrated variability up to 5 reading grade levels on the same text. The Simple Measure of Gobbledygook (SMOG) readability formula performed most consistently. Depending on the text sample size, selection, formatting, software, and/or hand calculations, the individual readability formula estimated up to 6 reading grade levels of variability. The SMOG formula appears best suited for health care applications because of its consistency of results, higher level of expected

  8. Assessing Online Patient Education Readability for Spine Surgery Procedures.

    Science.gov (United States)

    Long, William W; Modi, Krishna D; Haws, Brittany E; Khechen, Benjamin; Massel, Dustin H; Mayo, Benjamin C; Singh, Kern

    2018-03-01

    Increased patient reliance on Internet-based health information has amplified the need for comprehensible online patient education articles. As suggested by the American Medical Association and National Institute of Health, spine fusion articles should be written for a 4th-6th-grade reading level to increase patient comprehension, which may improve postoperative outcomes. The purpose of this study is to determine the readability of online health care education information relating to anterior cervical discectomy and fusion (ACDF) and lumbar fusion procedures. Online health-education resource qualitative analysis. Three search engines were utilized to access patient education articles for common cervical and lumbar spine procedures. Relevant articles were analyzed for readability using Readability Studio Professional Edition software (Oleander Software Ltd). Articles were stratified by organization type as follows: General Medical Websites (GMW), Healthcare Network/Academic Institutions (HNAI), and Private Practices (PP). Thirteen common readability tests were performed with the mean readability of each compared between subgroups using analysis of variance. ACDF and lumbar fusion articles were determined to have a mean readability of 10.7±1.5 and 11.3±1.6, respectively. GMW, HNAI, and PP subgroups had a mean readability of 10.9±2.9, 10.7±2.8, and 10.7±2.5 for ACDF and 10.9±3.0, 10.8±2.9, and 11.6±2.7 for lumbar fusion articles. Of 310 total articles, only 6 (3 ACDF and 3 lumbar fusion) were written for comprehension below a 7th-grade reading level. Current online literature from medical websites containing information regarding ACDF and lumbar fusion procedures are written at a grade level higher than the suggested guidelines. Therefore, current patient education articles should be revised to accommodate the average reading level in the United States and may result in improved patient comprehension and postoperative outcomes.

  9. Readability assessment of internet-based consumer health information.

    Science.gov (United States)

    Walsh, Tiffany M; Volsko, Teresa A

    2008-10-01

    A substantial amount of consumer health-related information is available on the Internet. Studies suggest that consumer comprehension may be compromised if content exceeds a 7th-grade reading level, which is the average American reading level identified by the United States Department of Health and Human Services (USDHHS). To determine the readability of Internet-based consumer health information offered by organizations that represent the top 5 medical-related causes of death in America. We hypothesized that the average readability (reading grade level) of Internet-based consumer health information on heart disease, cancer, stroke, chronic obstructive pulmonary disease, and diabetes would exceed the USDHHS recommended reading level. From the Web sites of the American Heart Association, American Cancer Society, American Lung Association, American Diabetes Association, and American Stroke Association we randomly gathered 100 consumer-health-information articles. We assessed each article with 3 readability-assessment tools: SMOG (Simple Measure of Gobbledygook), Gunning FOG (Frequency of Gobbledygook), and Flesch-Kincaid Grade Level. We also categorized the articles per the USDHHS readability categories: easy to read (below 6th-grade level), average difficulty (7th to 9th grade level), and difficult (above 9th-grade level). Most of the articles exceeded the 7th-grade reading level and were in the USDHHS "difficult" category. The mean +/- SD readability score ranges were: SMOG 11.80 +/- 2.44 to 14.40 +/- 1.47, Flesch-Kincaid 9.85 +/- 2.25 to 11.55 +/- 0.76, and Gunning FOG 13.10 +/- 3.42 to 16.05 +/- 2.31. The articles from the American Lung Association had the lowest reading-level scores with each of the readability-assessment tools. Our findings support that Web-based medical information intended for consumer use is written above USDHHS recommended reading levels. Compliance with these recommendations may increase the likelihood of consumer comprehension.

  10. A readability assessment of online stroke information.

    Science.gov (United States)

    Sharma, Nikhil; Tridimas, Andreas; Fitzsimmons, Paul R

    2014-07-01

    Patients and carers increasingly access the Internet as a source of health information. Poor health literacy is extremely common and frequently limits patient's comprehension of health care information literature. We aimed to assess the readability of online consumer-orientated stroke information using 2 validated readability measures. The 100 highest Google ranked consumer-oriented stroke Web pages were assessed for reading difficulty using the Flesch-Kincaid and Simple Measure of Gobbledygook (SMOG) formulae. None of the included Web pages complied with the current readability guidelines when readability was measured using the gold standard SMOG formula. Mean Flesch-Kincaid grade level was 10.4 (95% confidence interval [CI] 9.97-10.9) and mean SMOG grade 12.1 (95% CI 11.7-12.4). Over half of the Web pages were produced at graduate reading levels or above. Not-for-profit Web pages were significantly easier to read (P=.0006). The Flesch-Kincaid formula significantly underestimated reading difficulty, with a mean underestimation of 1.65 grades (95% CI 1.49-1.81), Preadability guidelines and to be comprehensible to the average patient. The Flesch-Kincaid formula significantly underestimates reading difficulty, and SMOG should be used as the measure of choice. Copyright © 2014 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  11. Readability of Brochures Produced by State of Florida.

    Science.gov (United States)

    Christ, William G.; Pharr, Paula

    1980-01-01

    A study of the readability of governmental pamphlets produced by the State of Florida, based on the use of the Flesch Reading Ease Formula and the Dale-Chall Formula, suggests that if a seventh or eighth grade readability level is considered an appropriate standard for public information brochures, the brochures tested may be too complex…

  12. Readability of online patient education materials on adult reconstruction Web sites.

    Science.gov (United States)

    Polishchuk, Daniil L; Hashem, Jenifer; Sabharwal, Sanjeev

    2012-05-01

    Recommended readability of patient education materials is sixth-grade level or lower. Readability of 212 patient education materials pertaining to adult reconstruction topics available from the American Academy of Orthopaedic Surgeons, American Association of Hip and Knee Surgeons, and 3 other specialty and private practitioner Web sites was assessed using the Flesch-Kincaid grade formula. The mean Flesch-Kincaid score was 11.1 (range, 3-26.5). Only 5 (2%) articles had a readability level of sixth grade or lower. Readability of most of the articles for patient education on adult reconstruction Web sites evaluated may be too advanced for a substantial portion of patients. Further studies are needed to assess the optimal readability level of health information on the Internet. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Clearly written, easily comprehended? The readability of websites providing information on epilepsy.

    Science.gov (United States)

    Brigo, Francesco; Otte, Willem M; Igwe, Stanley C; Tezzon, Frediano; Nardone, Raffaele

    2015-03-01

    There is a general need for high-quality, easily accessible, and comprehensive health-care information on epilepsy to better inform the general population about this highly stigmatized neurological disorder. The aim of this study was to evaluate the health literacy level of eight popular English-written websites that provide information on epilepsy in quantitative terms of readability. Educational epilepsy material on these websites, including 41 Wikipedia articles, were analyzed for their overall level of readability and the corresponding academic grade level needed to comprehend the published texts on the first reading. The Flesch Reading Ease (FRE) was used to assess ease of comprehension while the Gunning Fog Index, Coleman-Liau Index, Flesch-Kincaid Grade Level, Automated Readability Index, and Simple Measure of Gobbledygook scales estimated the corresponding academic grade level needed for comprehension. The average readability of websites yielded results indicative of a difficult-to-fairly-difficult readability level (FRE results: 44.0±8.2), with text readability corresponding to an 11th academic grade level (11.3±1.9). The average FRE score of the Wikipedia articles was indicative of a difficult readability level (25.6±9.5), with the other readability scales yielding results corresponding to a 14th grade level (14.3±1.7). Popular websites providing information on epilepsy, including Wikipedia, often demonstrate a low level of readability. This can be ameliorated by increasing access to clear and concise online information on epilepsy and health in general. Short "basic" summaries targeted to patients and nonmedical users should be added to articles published in specialist websites and Wikipedia to ease readability. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Improving the readability of online foot and ankle patient education materials.

    Science.gov (United States)

    Sheppard, Evan D; Hyde, Zane; Florence, Mason N; McGwin, Gerald; Kirchner, John S; Ponce, Brent A

    2014-12-01

    Previous studies have shown the need for improving the readability of many patient education materials to increase patient comprehension. This study's purpose was to determine the readability of foot and ankle patient education materials and to determine the extent readability can be improved. We hypothesized that the reading levels would be above the recommended guidelines and that decreasing the sentence length would also decrease the reading level of these patient educational materials. Patient education materials from online public sources were collected. The readability of these articles was assessed by a readability software program. The detailed instructions provided by the National Institutes of Health (NIH) were then used as a guideline for performing edits to help improve the readability of selected articles. The most quantitative guideline, lowering all sentences to less than 15 words, was chosen to show the effect of following the NIH recommendations. The reading levels of the sampled articles were above the sixth to seventh grade recommendations of the NIH. The MedlinePlus website, which is a part of the NIH website, had the lowest reading level (8.1). The articles edited had an average reduction of 1.41 grade levels, with the lowest reduction in the Medline articles of 0.65. Providing detailed instructions to the authors writing these patient education articles and implementing editing techniques based on previous recommendations could lead to an improvement in the readability of patient education materials. This study provides authors of patient education materials with simple editing techniques that will allow for the improvement in the readability of online patient educational materials. The improvement in readability will provide patients with more comprehendible education materials that can strengthen patient awareness of medical problems and treatments. © The Author(s) 2014.

  15. Readability assessment of patient education materials on major otolaryngology association websites.

    Science.gov (United States)

    Eloy, Jean Anderson; Li, Shawn; Kasabwala, Khushabu; Agarwal, Nitin; Hansberry, David R; Baredes, Soly; Setzen, Michael

    2012-11-01

    Various otolaryngology associations provide Internet-based patient education material (IPEM) to the general public. However, this information may be written above the fourth- to sixth-grade reading level recommended by the American Medical Association (AMA) and National Institutes of Health (NIH). The purpose of this study was to assess the readability of otolaryngology-related IPEMs on various otolaryngology association websites and to determine whether they are above the recommended reading level for patient education materials. Analysis of patient education materials from 9 major otolaryngology association websites. The readability of 262 otolaryngology-related IPEMs was assessed with 8 numerical and 2 graphical readability tools. Averages were evaluated against national recommendations and between each source using analysis of variance (ANOVA) with post hoc Tukey's honestly significant difference (HSD) analysis. Mean readability scores for each otolaryngology association website were compared. Mean website readability scores using Flesch Reading Ease test, Flesch-Kincaid Grade Level, Coleman-Liau Index, SMOG grading, Gunning Fog Index, New Dale-Chall Readability Formula, FORCAST Formula, New Fog Count Test, Raygor Readability Estimate, and the Fry Readability Graph ranged from 20.0 to 57.8, 9.7 to 17.1, 10.7 to 15.9, 11.6 to 18.2, 10.9 to 15.0, 8.6 to 16.0, 10.4 to 12.1, 8.5 to 11.8, 10.5 to 17.0, and 10.0 to 17.0, respectively. ANOVA results indicate a significant difference (P < .05) between the websites for each individual assessment. The IPEMs found on all otolaryngology association websites exceed the recommended fourth- to sixth-grade reading level.

  16. Assessing the Accuracy and Readability of Online Health Information for Patients With Pancreatic Cancer.

    Science.gov (United States)

    Storino, Alessandra; Castillo-Angeles, Manuel; Watkins, Ammara A; Vargas, Christina; Mancias, Joseph D; Bullock, Andrea; Demirjian, Aram; Moser, A James; Kent, Tara S

    2016-09-01

    The degree to which patients are empowered by written educational materials depends on the text's readability level and the accuracy of the information provided. The association of a website's affiliation or focus on treatment modality with its readability and accuracy has yet to be thoroughly elucidated. To compare the readability and accuracy of patient-oriented online resources for pancreatic cancer by treatment modality and website affiliation. An online search of 50 websites discussing 5 pancreatic cancer treatment modalities (alternative therapy, chemotherapy, clinical trials, radiation therapy, and surgery) was conducted. The website's affiliation was identified. Readability was measured by 9 standardized tests, and accuracy was assessed by an expert panel. Nine standardized tests were used to compute the median readability level of each website. The median readability scores were compared among treatment modality and affiliation categories. Accuracy was determined by an expert panel consisting of 2 medical specialists and 2 surgical specialists. The 4 raters independently evaluated all websites belonging to the 5 treatment modalities (a score of 1 indicates that readability and accuracy based on the focus of the treatment modality and the website's affiliation. Websites discussing surgery (with a median readability level of 13.7 and an interquartile range [IQR] of 11.9-15.6) were easier to read than those discussing radiotherapy (median readability level, 15.2 [IQR, 13.0-17.0]) (P = .003) and clinical trials (median readability level, 15.2 [IQR, 12.8-17.0]) (P = .002). Websites of nonprofit organizations (median readability level, 12.9 [IQR, 11.2-15.0]) were easier to read than media (median readability level, 16.0 [IQR, 13.4-17.0]) (P readability level, 14.8 [IQR, 12.9-17.0]) (P readability level, 14.0 [IQR, 12.1-16.1]) were easier to read than media websites (P = .001). Among treatment modalities, alternative therapy websites exhibited the

  17. Readability of patient information and consent documents in rheumatological studies.

    Science.gov (United States)

    Hamnes, Bente; van Eijk-Hustings, Yvonne; Primdahl, Jette

    2016-07-16

    Before participation in medical research an informed consent must be obtained. This study investigates whether the readability of patient information and consent documents (PICDs) corresponds to the average educational level of participants in rheumatological studies in the Netherlands, Denmark, and Norway. 24 PICDs from studies were collected and readability was assessed independently using the Gunning's Fog Index (FOG) and Simple Measure of Gobbledygook (SMOG) grading. The mean score for the FOG and SMOG grades were 14.2 (9.0-19.0) and 14.2 (12-17) respectively. The mean FOG and SMOG grades were 12.7 and 13.3 in the Dutch studies, 15.0 and 14.9 in the Danish studies, and 14.6 and 14.3 in the Norwegian studies, respectively. Out of the 2865 participants, more than 57 % had a lower educational level than the highest readability score calculated in the individual study. As the readability level of the PICDs did not match the participants' educational level, consent may not have been valid, as the participants may have had a limited understanding of what they agreed to participate in. There should be more focus on the readability of PICDs. National guidelines for how to write clear and unambiguous PICDs in simple and easily understandable language could increase the focus on the readability of PICD.

  18. Readability of Internet Information on Hearing: Systematic Literature Review.

    Science.gov (United States)

    Laplante-Lévesque, Ariane; Thorén, Elisabet Sundewall

    2015-09-01

    This systematic literature review asks the following question: “ What is the readability of Internet information on hearing that people with hearing impairment and their significant others can access in the context of their hearing care?” Searches were completed in three databases: CINAHL, PubMed, and Scopus. Seventy-eight records were identified and systematically screened for eligibility: 8 records were included that contained data on the readability of Internet information on hearing that people with hear ing impairment and their significant others can access in the context of their hearing care. Records reported mean readability levels from 9 to over 14. In other words, people with hearing impairment and their significant others need 9 to 14 years of education to read and understand Internet information on hearing that they access in the context of their hearing care. The poor readability of Internet information on hearing has been well documented; it is time to focus on valid and sustainable initiatives that address this problem.

  19. Readability Assessment of Online Patient Education Material on Congestive Heart Failure

    Science.gov (United States)

    2017-01-01

    Background Online health information is being used more ubiquitously by the general population. However, this information typically favors only a small percentage of readers, which can result in suboptimal medical outcomes for patients. Objective The readability of online patient education materials regarding the topic of congestive heart failure was assessed through six readability assessment tools. Methods The search phrase “congestive heart failure” was employed into the search engine Google. Out of the first 100 websites, only 70 were included attending to compliance with selection and exclusion criteria. These were then assessed through six readability assessment tools. Results Only 5 out of 70 websites were within the limits of the recommended sixth-grade readability level. The mean readability scores were as follows: the Flesch-Kincaid Grade Level (9.79), Gunning-Fog Score (11.95), Coleman-Liau Index (15.17), Simple Measure of Gobbledygook (SMOG) index (11.39), and the Flesch Reading Ease (48.87). Conclusion Most of the analyzed websites were found to be above the sixth-grade readability level recommendations. Efforts need to be made to better tailor online patient education materials to the general population. PMID:28656111

  20. Electricity of machine tool

    International Nuclear Information System (INIS)

    Gijeon media editorial department

    1977-10-01

    This book is divided into three parts. The first part deals with electricity machine, which can taints from generator to motor, motor a power source of machine tool, electricity machine for machine tool such as switch in main circuit, automatic machine, a knife switch and pushing button, snap switch, protection device, timer, solenoid, and rectifier. The second part handles wiring diagram. This concludes basic electricity circuit of machine tool, electricity wiring diagram in your machine like milling machine, planer and grinding machine. The third part introduces fault diagnosis of machine, which gives the practical solution according to fault diagnosis and the diagnostic method with voltage and resistance measurement by tester.

  1. The Readability of Online Resources for Mastopexy Surgery.

    Science.gov (United States)

    Vargas, Christina R; Chuang, Danielle J; Lee, Bernard T

    2016-01-01

    As more patients use Internet resources for health information, there is increasing interest in evaluating the readability of available online materials. The National Institutes of Health and American Medical Association recommend that patient educational content be written at a sixth-grade reading level. This study evaluates the most popular online resources for information about mastopexy relative to average adult literacy in the United States. The 12 most popular sites returned by the largest Internet search engine were identified using the search term "breast lift surgery." Relevant articles from the main sites were downloaded and formatted into text documents. Pictures, captions, links, and references were excluded. The readability of these 100 articles was analyzed overall and subsequently by site using 10 established readability tests. Subgroup analysis was performed for articles discussing the benefits of surgery and those focusing on risks. The overall average readability of online patient information was 13.3 (range, 11.1-15). There was a range of average readability scores overall across the 12 sites from 8.9 to 16.1, suggesting that some may be more appropriate than others for patient demographics with different health literacy levels. Subgroup analysis revealed that articles discussing the risks of mastopexy were significantly harder to read (mean, 14.1) than articles about benefits (11.6). Patient-directed articles from the most popular online resources for mastopexy information are uniformly above the recommended reading level and likely too difficult to be understood by a large number of patients in the United States.

  2. Quality and Readability of English-Language Internet Information for Voice Disorders.

    Science.gov (United States)

    Dueppen, Abigail J; Bellon-Harn, Monica L; Radhakrishnan, Nandhakumar; Manchaiah, Vinaya

    2017-12-15

    The purpose of this study is to evaluate the readability and quality of English-language Internet information related to vocal hygiene, vocal health, and prevention of voice disorders. This study extends recent work because it evaluates readability, content quality, and website origin across broader search criteria than previous studies evaluating online voice material. Eighty-five websites were aggregated using five different country-specific search engines. Websites were then analyzed using quality and readability assessments. The entire web page was evaluated; however, no information or links beyond the first page was reviewed. Statistical calculations were employed to examine website ratings, differences between website origin and quality and readability scores, and correlations between readability instruments. Websites exhibited acceptable quality as measured by the DISCERN. However, only one website obtained the Health On the Net certification. Significant differences in quality were found among website origin, with government websites receiving higher quality ratings. Approximate educational levels required to comprehend information on the websites ranged from 8 to 9 years of education. Significant differences were found between website origin and readability measures with higher levels of education required to understand information on websites of nonprofit organizations. Current vocal hygiene, vocal health, and prevention of voice disorders websites were found to exhibit acceptable levels of quality and readability. However, highly rated Internet information related to voice care should be made more accessible to voice clients through Health On the Net certification. Published by Elsevier Inc.

  3. Control processes and machine protection on ASDEX Upgrade

    International Nuclear Information System (INIS)

    Raupp, G.; Treutterer, W.; Mertens, V.; Neu, G.; Sips, A.; Zasche, D.; Zehetbauer, Th.

    2007-01-01

    Safe operation of ASDEX Upgrade is guaranteed by a conventional hierarchy of simple and robust hard-wired systems for personnel and machine protection featuring standardized switch-off procedures. Machine protection and handling of off-normal events is further enhanced and peak and lifetime stress minimized through the plasma control system. Based on a real-time process model supporting safety critical applications with data quality tagging, process self-monitoring, watchdog monitoring and alarm propagation, processes detect complex and critical failures and reliably perform case-sensitive counter measures. Intelligent real-time failure handling is done with hardware or software redundancy and performance degradation, or modification of reference values to continue or terminate discharges with reduced machine stress. Examples implemented so far on ASDEX Upgrade are given, such as recovery from measurement failures, switch-over of redundant actuators, handling of actuator limitations, detection of plasma instabilities, plasma state dependent soft landing, or handling of failed switch-off procedures through breakers disconnecting the machine from grid

  4. Readability as a Factor in Magazine Ad Copy Recall.

    Science.gov (United States)

    Wesson, David A.

    1989-01-01

    Examines the relationship between advertising copy readability and advertising effectiveness. Finds that recall is improved when the copy style is either fairly easy or fairly hard to read. Suggests the value of considering copy readability as a potential contributor, though a minor one, to the success of magazine advertising. (RS)

  5. Consent information leaflets - readable or unreadable?

    Science.gov (United States)

    Graham, Caroline; Reynard, John M; Turney, Benjamin W

    2015-05-01

    The objective of this article is to assess the readability of leaflets about urological procedures provided by the British Association of Urological Surgeons (BAUS) to evaluate their suitability for providing information. Information leaflets were assessed using three measures of readability: Flesch Reading Ease, Flesch-Kincaid and Simple Measure of Gobbledygook (SMOG) grade formulae. The scores were compared with national literacy statistics. Relatively good readability was demonstrated using the Flesch Reading Ease (53.4-60.1) and Flesch-Kincaid Grade Level (6.5-7.6) methods. However, the average SMOG index (14.0-15.0) for each category suggests that the majority of the leaflets are written above the reading level of an 18-year-old. Using national literacy statistics, at least 43% of the population will have significant difficultly understanding the majority of these leaflets. The results suggest that comprehension of the leaflets provided by the BAUS is likely to be poor. These leaflets may be used as an adjunct to discussion but it is essential to ensure that all the information necessary to make an informed decision has been conveyed in a way that can be understood by the patient.

  6. Readability Assessment of Patient Information about Lymphedema and Its Treatment.

    Science.gov (United States)

    Seth, Akhil K; Vargas, Christina R; Chuang, Danielle J; Lee, Bernard T

    2016-02-01

    Patient use of online resources for health information is increasing, and access to appropriately written information has been associated with improved patient satisfaction and overall outcomes. The American Medical Association and the National Institutes of Health recommend that patient materials be written at a sixth-grade reading level. In this study, the authors simulated a patient search of online educational content for lymphedema and evaluated readability. An online search for the term "lymphedema" was performed, and the first 12 hits were identified. User and location filters were disabled and sponsored results were excluded. Patient information from each site was downloaded and formatted into plain text. Readability was assessed using established tests: Coleman-Liau, Flesch-Kincaid, Flesch Reading Ease Index, FORCAST Readability Formula, Fry Graph, Gunning Fog Index, New Dale-Chall Formula, New Fog Count, Raygor Readability Estimate, and Simple Measure of Gobbledygook Readability Formula. There were 152 patient articles downloaded; the overall mean reading level was 12.6. Individual website reading levels ranged from 9.4 (cancer.org) to 16.7 (wikipedia.org). There were 36 articles dedicated to conservative treatments for lymphedema; surgical treatment was mentioned in nine articles across four sites. The average reading level for conservative management was 12.7, compared with 15.6 for surgery (p readability, and surgeons should direct patients to sites appropriate for their level. There is limited information about surgical treatment available on the most popular sites; this information is significantly harder to read than sections on conservative measures.

  7. Readability Level of Spanish-Language Patient-Reported Outcome Measures in Audiology and Otolaryngology

    Science.gov (United States)

    Coco, Laura; Colina, Sonia; Atcherson, Samuel R.

    2017-01-01

    Purpose The purpose of this study was to examine the readability level of the Spanish versions of several audiology- and otolaryngology-related patient-reported outcome measures (PROMs) and include a readability analysis of 2 translation approaches when available—the published version and a “functionalist” version—using a team-based collaborative approach including community members. Method Readability levels were calculated using the Fry Graph adapted for Spanish, as well as the Fernandez-Huerta and the Spaulding formulae for several commonly used audiology- and otolaryngology-related PROMs. Results Readability calculations agreed with previous studies analyzing audiology-related PROMs in English and demonstrated many Spanish-language PROMs were beyond the 5th grade reading level suggested for health-related materials written for the average population. In addition, the functionalist versions of the PROMs yielded lower grade-level (improved) readability levels than the published versions. Conclusion Our results suggest many of the Spanish-language PROMs evaluated here are beyond the recommended readability levels and may be influenced by the approach to translation. Moreover, improved readability may be possible using a functionalist approach to translation. Future analysis of the suitability of outcome measures and the quality of their translations should move beyond readability and include an evaluation of the individual's comprehension of the written text. PMID:28892821

  8. Bacterial foraging-optimized PID control of a two-wheeled machine with a two-directional handling mechanism.

    Science.gov (United States)

    Goher, K M; Fadlallah, S O

    2017-01-01

    This paper presents the performance of utilizing a bacterial foraging optimization algorithm on a PID control scheme for controlling a five DOF two-wheeled robotic machine with two-directional handling mechanism. The system under investigation provides solutions for industrial robotic applications that require a limited-space working environment. The system nonlinear mathematical model, derived using Lagrangian modeling approach, is simulated in MATLAB/Simulink ® environment. Bacterial foraging-optimized PID control with decoupled nature is designed and implemented. Various working scenarios with multiple initial conditions are used to test the robustness and the system performance. Simulation results revealed the effectiveness of the bacterial foraging-optimized PID control method in improving the system performance compared to the PID control scheme.

  9. readability of comprehension passages in junior high school (jhs)

    African Journals Online (AJOL)

    CHARLES

    ... to enhance readability. Key Words: readability formulas, comprehension passages, Junior High School, .... Index has a manual version but in this study the electronic version was used. The ..... probably the majority of the people heard the news by word of mouth. A critical look ..... The Journal of Tourism Studies 9.2: 49-60.

  10. Exploration on Automated Software Requirement Document Readability Approaches

    OpenAIRE

    Chen, Mingda; He, Yao

    2017-01-01

    Context. The requirements analysis phase, as the very beginning of software development process, has been identified as a quite important phase in the software development lifecycle. Software Requirement Specification (SRS) is the output of requirements analysis phase, whose quality factors play an important role in the evaluation work. Readability is a quite important SRS quality factor, but there are few available automated approaches for readability measurement, because of the tight depend...

  11. Cellular Handling of Protein Aggregates by Disaggregation Machines.

    Science.gov (United States)

    Mogk, Axel; Bukau, Bernd; Kampinga, Harm H

    2018-01-18

    Both acute proteotoxic stresses that unfold proteins and expression of disease-causing mutant proteins that expose aggregation-prone regions can promote protein aggregation. Protein aggregates can interfere with cellular processes and deplete factors crucial for protein homeostasis. To cope with these challenges, cells are equipped with diverse folding and degradation activities to rescue or eliminate aggregated proteins. Here, we review the different chaperone disaggregation machines and their mechanisms of action. In all these machines, the coating of protein aggregates by Hsp70 chaperones represents the conserved, initializing step. In bacteria, fungi, and plants, Hsp70 recruits and activates Hsp100 disaggregases to extract aggregated proteins. In the cytosol of metazoa, Hsp70 is empowered by a specific cast of J-protein and Hsp110 co-chaperones allowing for standalone disaggregation activity. Both types of disaggregation machines are supported by small Hsps that sequester misfolded proteins. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Formalizing the Safety of Java, the Java Virtual Machine and Java Card

    NARCIS (Netherlands)

    Hartel, Pieter H.; Moreau, Luc

    2001-01-01

    We review the existing literature on Java safety, emphasizing formal approaches, and the impact of Java safety on small footprint devices such as smart cards. The conclusion is that while a lot of good work has been done, a more concerted effort is needed to build a coherent set of machine readable

  13. Textbooks in Management, Marketing and Finance: An Analysis of Readability.

    Science.gov (United States)

    Gallagher, Daniel J.; Thompson, G. Rodney

    1982-01-01

    Examines the readability of texts in basic junior level college courses in the fields of management, marketing, and finance. The readability model is described, along with its application and results. Specific texts and how they fared are listed in accompanying tables. (CT)

  14. Universally Designed Text on the Web: Towards Readability Criteria Based on Anti-Patterns.

    Science.gov (United States)

    Eika, Evelyn

    2016-01-01

    The readability of web texts affects accessibility. The Web Content Accessibility guidelines (WCAG) state that the recommended reading level should match that of someone who has completed basic schooling. However, WCAG does not give advice on what constitutes an appropriate reading level. Web authors need tools to help composing WCAG compliant texts, and specific criteria are needed. Classic readability metrics are generally based on lengths of words and sentences and have been criticized for being over-simplistic. Automatic measures and classifications of texts' reading levels employing more advanced constructs remain an unresolved problem. If such measures were feasible, what should these be? This work examines three language constructs not captured by current readability indices but believed to significantly affect actual readability, namely, relative clauses, garden path sentences, and left-branching structures. The goal is to see whether quantifications of these stylistic features reflect readability and how they correspond to common readability measures. Manual assessments of a set of authentic web texts for such uses were conducted. The results reveal that texts related to narratives such as children's stories, which are given the highest readability value, do not contain these constructs. The structures in question occur more frequently in expository texts that aim at educating or disseminating information such as strategy and journal articles. The results suggest that language anti-patterns hold potential for establishing a set of deeper readability criteria.

  15. Evaluation of the Readability of Dermatological Postoperative Patient Information Leaflets Across England.

    Science.gov (United States)

    Hunt, William T N; McGrath, Emily J

    2016-06-01

    Postoperative patient information leaflets (PILs) provide important guidance to patients after skin surgery. Readability is a method of evaluating information for text comprehension. The recommended level for PIL readability is US grade ≤6. To evaluate the readability of public English dermatological postoperative PILs. All dermatology departments in England were requested to provide their postoperative PILs. Patient information leaflets were evaluated using Readability Studio (Oleander Software, Vandalia, OH). Two preselected parameters were also noted: whether the PIL was doctor or nurse-written, and whether the PIL was Information Standard hallmarked. Eighty-five of one hundred thirty (65.4%) of PILs were evaluated. Only 29.4% of the PILs were grade level ≤6 with Flesch-Kincaid. The mean readability levels were 7.8 for Flesch-Kincaid, 67 for Flesch reading ease, 10.5 for Simple Measure of Gobbledygook (SMOG), 9.4 for Gunning-Fog, 8 for Fry, and 9.8 for FORCAST. No instruments demonstrated a significant difference between doctor (6) and nurse-written (7) PILs. Two instruments found that the 3 Information Standard hallmarked PILs had a higher (harder) readability than ordinary PILs (n = 82) (Gunning-Fog, p = .029*; SMOG p = .049*). Most English postoperative dermatological PILs' readability levels exceed recommendations (US grade ≤6). Departmental PILs should be reviewed to ensure that they are comprehensible to their patients.

  16. Readability of Orthopedic Trauma Patient Education Materials on the Internet.

    Science.gov (United States)

    Mohan, Rohith; Yi, Paul H; Morshed, Saam

    In this study, we used the Flesch-Kincaid Readability Scale to determine the readability levels of orthopedic trauma patient education materials on the American Academy of Orthopaedic Surgeons (AAOS) website and to examine how subspecialty coauthorship affects readability level. Included articles from the AAOS online patient education library and the AAOS OrthoPortal website were categorized as trauma or broken bones and injuries on the AAOS online library or were screened by study authors for relevance to orthopedic trauma. Subsequently, the Flesch-Kincaid scale was used to determine each article's readability level, which was reported as a grade level. Subspecialty coauthorship was noted for each article. A total of 115 articles from the AAOS website were included in the study and reviewed. Mean reading level was grade 9.1 for all articles reviewed. Nineteen articles (16.5%) were found to be at or below the eighth-grade level, and only 1 article was at or below the sixth-grade level. In addition, there was no statistically significant difference between articles coauthored by the various orthopedic subspecialties and those authored exclusively by AAOS. Orthopedic trauma readability materials on the AAOS website appear to be written at a reading comprehension level too high for the average patient to understand.

  17. Measuring the Readability of Elementary Algebra Using the Cloze Technique.

    Science.gov (United States)

    Kulm, Gerald

    The relationship to readability of ten variables characterizing structural properties of mathematical prose was investigated in elementary algebra textbooks. Readability was measured by algebra student's responses to two forms of cloze tests. Linear and currilinear correlations were calculated between each structural variable and the cloze test.…

  18. Readability of "Dear Patient" device advisory notification letters created by a device manufacturer.

    Science.gov (United States)

    Mueller, Luke A; Sharma, Arjun; Ottenberg, Abigale L; Mueller, Paul S

    2013-04-01

    In 2006, the Heart Rhythm Society (HRS) recommended that cardiovascular implantable electronic device (CIED) manufacturers use advisory notification letters to communicate with affected patients. To evaluate the readability of the HRS sample "patient device advisory notification" letter and those created by 1 CIED manufacturer. The HRS sample letter and 25 Boston Scientific Corporation letters dated from 2005 through 2011 were evaluated by using 6 readability tests. Readability (Flesch-Kincaid score) of the HRS sample letter was grade level 12.5, and median readability of the device manufacturer letters was grade level 12.8 (range 10.8-18.9). Similar results were obtained by using other readability scales. No letters had readability scores at the National Work Group on Literacy and Health's recommended reading level-fifth grade; the letters' readability exceeded this recommended level by an average of 7.7 grades (95% confidence interval 6.9-8.5; Preadability scores at the average reading level of US adults-eighth grade; the letters' readability exceeded this level by an average of 4.7 grades (95% confidence interval 3.9-5.5; Preadability of the HRS sample letter and those created by a CIED manufacturer significantly exceeded the recommended and average US adults' reading skill levels. Such letters are unlikely to be informative to many patients. CIED manufacturers should ensure that advisory letters are comprehensible to most affected patients. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  19. Virtual Machine Language

    Science.gov (United States)

    Grasso, Christopher; Page, Dennis; O'Reilly, Taifun; Fteichert, Ralph; Lock, Patricia; Lin, Imin; Naviaux, Keith; Sisino, John

    2005-01-01

    Virtual Machine Language (VML) is a mission-independent, reusable software system for programming for spacecraft operations. Features of VML include a rich set of data types, named functions, parameters, IF and WHILE control structures, polymorphism, and on-the-fly creation of spacecraft commands from calculated values. Spacecraft functions can be abstracted into named blocks that reside in files aboard the spacecraft. These named blocks accept parameters and execute in a repeatable fashion. The sizes of uplink products are minimized by the ability to call blocks that implement most of the command steps. This block approach also enables some autonomous operations aboard the spacecraft, such as aerobraking, telemetry conditional monitoring, and anomaly response, without developing autonomous flight software. Operators on the ground write blocks and command sequences in a concise, high-level, human-readable programming language (also called VML ). A compiler translates the human-readable blocks and command sequences into binary files (the operations products). The flight portion of VML interprets the uplinked binary files. The ground subsystem of VML also includes an interactive sequence- execution tool hosted on workstations, which runs sequences at several thousand times real-time speed, affords debugging, and generates reports. This tool enables iterative development of blocks and sequences within times of the order of seconds.

  20. Readability Levels of the 1975 Third Grade Macmillan Basal Readers.

    Science.gov (United States)

    McKinney, Ernestine Williams

    1983-01-01

    Analysis of third-grade books in the New Macmillan Reading Program reveals that the books exceeded the publisher's designation of readability and did not progress in difficulty from easy to more difficult. Findings suggest the need for more complete and reliable information from publishers concerning textbook readability. (FL)

  1. Readability and Reading Ability.

    Science.gov (United States)

    Wright, Benjamin D.; Stenner, A. Jackson

    This document discusses the measurement of reading ability and the readability of books by application of the Lexile framework. It begins by stating the importance of uniform measures. It then discusses the history of reading ability testing, based on the assumption that no researcher has been able to measure more than one kind of reading ability.…

  2. Readability and suitability assessment of patient education materials in rheumatic diseases.

    Science.gov (United States)

    Rhee, Rennie L; Von Feldt, Joan M; Schumacher, H Ralph; Merkel, Peter A

    2013-10-01

    Web-based patient education materials and printed pamphlets are frequently used by providers to inform patients about their rheumatic disease. Little attention has been given to the readability and appropriateness of patient materials. The objective of this study was to examine the readability and suitability of commonly used patient education materials for osteoarthritis (OA), rheumatoid arthritis, systemic lupus erythematosus, and vasculitis. Five or 6 popular patient resources for each disease were chosen for evaluation. Readability was measured using the Flesch-Kincaid reading grade level and suitability was determined by the Suitability Assessment of Materials (SAM), a score that considers characteristics such as content, graphics, layout/topography, and cultural appropriateness. Three different reviewers rated the SAM score and means were used in the analysis. Twenty-three resources written on the 4 diseases were evaluated. The education material for all 4 diseases studied had readability above the eighth-grade level and readability did not differ among the diseases. Only 5 of the 23 resources received superior suitability scores, and 3 of these 5 resources were written for OA. All 4 diseases received adequate suitability scores, with OA having the highest mean suitability score. Most patient education materials for rheumatic diseases are written at readability levels above the recommended sixth-grade reading level and have only adequate suitability. Developing more appropriate educational resources for patients with rheumatic diseases may improve patient comprehension. Copyright © 2013 by the American College of Rheumatology.

  3. Assessing readability of patient education materials: current role in orthopaedics.

    Science.gov (United States)

    Badarudeen, Sameer; Sabharwal, Sanjeev

    2010-10-01

    Health literacy is the single best predictor of an individual's health status. It is important to customize health-related education material to the individual patient's level of reading skills. Readability of a given text is the objective measurement of the reading skills one should possess to understand the written material. In this article, some of the commonly used readability assessment tools are discussed and guidelines to improve the comprehension of patient education handouts are provided. Where are we now? Several healthcare organizations have recommended the readability of patient education materials be no higher than sixth- to eighth-grade level. However, most of the patient education materials currently available on major orthopaedic Web sites are written at a reading level that may be too advanced for comprehension by a substantial proportion of the population. WHERE DO WE NEED TO GO?: There are several readily available and validated tools for assessing the readability of written materials. While use of audiovisual aids such as video clips, line drawings, models, and charts can enhance the comprehension of a health-related topic, standard readability tools cannot construe such enhancements. HOW DO WE GET THERE?: Given the variability in the capacity to comprehend health-related materials among individuals seeking orthopaedic care, stratifying the contents of patient education materials at different levels of complexity will likely improve health literacy and enhance patient-centered communication.

  4. Team effort leads to versatile handling solution for pipe manufacturer

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2010-09-15

    This article discussed the development of a new pipe-handling system that resulted in increased efficiencies in plant-to-yard transport for a custom steel pipe manufacturer. In the previous system, loaders would move finished pipe to the yard for storage. However, for transport loading, the pipe would have to be brought back indoors because only the inside cranes could handle loading the pipe without damaging the special outer coating on the pipe. In the new pipe-handling system, the loader is replaced with a Sennebogen 850 M rubber-tired material handler, which was developed for the steel recycling industry. The generator that comes on the material handler is retrofitted to power a purpose-built pipe-handler attachment. The machine's higher lifting reach allows for higher stacking, effectively increasing the capacity of the yard. The new pipe-handling machine allows trucks to be loaded right in the yard, eliminating the need to double-handle the pipe. 1 fig.

  5. Initial Readability Assessment of Clinical Trial Eligibility Criteria

    Science.gov (United States)

    Kang, Tian; Elhadad, Noémie; Weng, Chunhua

    2015-01-01

    Various search engines are available to clinical trial seekers. However, it remains unknown how comprehensible clinical trial eligibility criteria used for recruitment are to a lay audience. This study initially investigated this problem. Readability of eligibility criteria was assessed according to (i) shallow and lexical characteristics through the use of an established, generic readability metric; (ii) syntactic characteristics through natural language processing techniques; and (iii) health terminological characteristics through an automated comparison to technical and lay health texts. We further stratified clinical trials according to various study characteristics (e.g., source country or study type) to understand potential factors influencing readability. Mainly caused by frequent use of technical jargons, a college reading level was found to be necessary to understand eligibility criteria text, a level much higher than the average literacy level of the general American population. The use of technical jargons should be minimized to simplify eligibility criteria text. PMID:26958204

  6. Readability of patient education materials on the American Orthopaedic Society for Sports Medicine website.

    Science.gov (United States)

    Eltorai, Adam E M; Han, Alex; Truntzer, Jeremy; Daniels, Alan H

    2014-11-01

    The recommended readability of patient education materials by the American Medical Association (AMA) and National Institutes of Health (NIH) should be no greater than a sixth-grade reading level. However, online resources may be too complex for some patients to understand, and poor health literacy predicts inferior health-related quality of life outcomes. This study evaluated whether the American Orthopaedic Society for Sports Medicine (AOSSM) website's patient education materials meet recommended readability guidelines for medical information. We hypothesized that the readability of these online materials would have a Flesch-Kincaid formula grade above the sixth grade. All 65 patient education entries of the AOSSM website were analyzed for grade level readability using the Flesch-Kincaid formula, a widely used and validated tool to evaluate the text reading level. The average (standard deviation) readability of all 65 articles was grade level 10.03 (1.44); 64 articles had a readability score above the sixth-grade level, which is the maximum level recommended by the AMA and NIH. Mean readability of the articles exceeded this level by 4.03 grade levels (95% CI, 3.7-4.4; P reading level of US adults. Mean readability of the articles exceeded this level by 2.03 grade levels (95% CI, 1.7-2.4; P online AOSSM patient education materials exceeds the readability level recommended by the AMA and NIH, and is above the average reading level of the majority of US adults. This online information may be of limited utility to most patients due to a lack of comprehension. Our study provides a clear example of the need to improve the readability of specific education material in order to maximize the efficacy of multimedia sources.

  7. Readability of Online Patient Education Materials Related to IR.

    Science.gov (United States)

    McEnteggart, Gregory E; Naeem, Muhammad; Skierkowski, Dorothy; Baird, Grayson L; Ahn, Sun H; Soares, Gregory

    2015-08-01

    To assess the readability of online patient education materials (OPEM) related to common diseases treated by and procedures performed by interventional radiology (IR). The following websites were chosen based on their average Google search return for each IR OPEM content area examined in this study: Society of Interventional Radiology (SIR), Cardiovascular and Interventional Radiological Society of Europe (CIRSE), National Library of Medicine, RadiologyInfo, Mayo Clinic, WebMD, and Wikipedia. IR OPEM content area was assessed for the following: peripheral arterial disease, central venous catheter, varicocele, uterine artery embolization, vertebroplasty, transjugular intrahepatic portosystemic shunt, and deep vein thrombosis. The following algorithms were used to estimate and compare readability levels: Flesch-Kincaid Grade Formula, Flesch Reading Ease Score, Gunning Frequency of Gobbledygook, Simple Measure of Gobbledygook, and Coleman-Liau Index. Data were analyzed using general mixed modeling. On average, online sources that required beyond high school grade-level readability were Wikipedia (15.0), SIR (14.2), and RadiologyInfo (12.4); sources that required high school grade-level readability were CIRSE (11.3), Mayo Clinic (11.0), WebMD (10.6), and National Library of Medicine (9.0). On average, OPEM on uterine artery embolization, vertebroplasty, varicocele, and peripheral arterial disease required the highest level of readability (12.5, 12.3, 12.3, and 12.2, respectively). The IR OPEM assessed in this study were written above the recommended sixth-grade reading level and the health literacy level of the average American adult. Many patients in the general public may not have the ability to read and understand health information in IR OPEM. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  8. Readability and quality of wikipedia pages on neurosurgical topics.

    Science.gov (United States)

    Modiri, Omeed; Guha, Daipayan; Alotaibi, Naif M; Ibrahim, George M; Lipsman, Nir; Fallah, Aria

    2018-03-01

    Wikipedia is the largest online encyclopedia with over 40 million articles, and generating 500 million visits per month. The aim of this study is to assess the readability and quality of Wikipedia pages on neurosurgical related topics. We selected the neurosurgical related Wikipedia pages based on the series of online patient information articles that are published by the American Association of Neurological Surgeons (AANS). We assessed readability of Wikipedia pages using five different readability scales (Flesch Reading Ease, Flesch Kincaid Grade Level, Gunning Fog Index, SMOG) Grade level, and Coleman-Liau Index). We used the Center for Disease Control (CDC) Clear Communication Index as well as the DISCERN Instrument to evaluate the quality of each Wikipedia article. We identified a total of fifty-five Wikipedia articles that corresponded with patient information articles published by the AANS. This constitutes 77.46% of the AANS topics. The mean Flesch Kincaid reading ease score for all of the Wikipedia articles we analyzed is 31.10, which indicates that a college-level education is necessary to understand them. In comparison to the readability analysis for the AANS articles, the Wikipedia articles were more difficult to read across every scale. None of the Wikipedia articles meet the CDC criterion for clear communications. Our analyses demonstrated that Wikipedia articles related to neurosurgical topics are associated with higher grade levels for reading and also below the expected levels of clear communications for patients. Collaborative efforts from the neurosurgical community are needed to enhance the readability and quality of Wikipedia pages related to neurosurgery. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Readability analysis of online resources related to lung cancer.

    Science.gov (United States)

    Weiss, Kathleen D; Vargas, Christina R; Ho, Olivia A; Chuang, Danielle J; Weiss, Jonathan; Lee, Bernard T

    2016-11-01

    Patients seeking health information commonly use the Internet as the first source for material. Studies show that well-informed patients have increased involvement, satisfaction, and healthcare outcomes. As one-third of Americans have only basic or below basic health literacy, the National Institutes of Health and American Medical Association recommend patient-directed health resources be written at a sixth-grade reading level. This study evaluates the readability of commonly accessed online resources on lung cancer. A search for "lung cancer" was performed using Google and Bing, and the top 10 websites were identified. Location services were disabled, and sponsored sites were excluded. Relevant articles (n = 109) with patient-directed content available directly from the main sites were downloaded. Readability was assessed using 10 established methods and analyzed with articles grouped by parent website. The average reading grade level across all sites was 11.2, with a range from 8.8 (New Fog Count) to 12.2 (Simple Measure of Gobbledygook). The average Flesch Reading Ease score was 52, corresponding with fairly difficult to read text. The readability varied when compared by individual website, ranging in grade level from 9.2 to 15.2. Only 10 articles (9%) were written below a sixth-grade level and these tended to discuss simpler topics. Patient-directed online information about lung cancer exceeds the recommended sixth-grade reading level. Readability varies between individual websites, allowing physicians to direct patients according to level of health literacy. Modifications to existing materials can significantly improve readability while maintaining content for patients with low health literacy. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Reading apps for children: Readability from the design perspective

    Science.gov (United States)

    Mohammed, Wasan Abdulwahab; Husni, Husniza

    2017-10-01

    Electronic reading for young children opens new avenues especially with the advance of modern reading devices. The readability of mobile learning applications has received extensive attention by the designers and developers. The reason for such concern is due to its importance in determining usability related issues especially in the design context for children. In many cases, children find it difficult to interact with mobile reading apps. This is because apps for reading and for entertainment require different features. As such, this study sets out three objectives: 1) to evaluate five reading apps for young children from design perspectives; 2) to examine the readability for current existing mobile apps for reading and 3) to propose and evaluate mobile apps UI guideline for readability. Readability indices, observation and interview were conducted on 6 - 8 years old students. The obtained result showed that certain reading apps provide better reading experience for children than others. Some of the reasons are mostly related to the design characteristics embedded within the app. In addition, the use of animation was found to stimulate children reading experience as it is believed to offer the interactivity elements to gain their interest and willingness to read. These findings are believed to provide the recommendations and insights for designers of reading apps for children.

  11. The quality and readability of online consumer information about gynecologic cancer.

    Science.gov (United States)

    Sobota, Aleksandra; Ozakinci, Gozde

    2015-03-01

    The Internet has become an important source of health-related information for consumers, among whom younger women constitute a notable group. The aims of this study were (1) to evaluate the quality and readability of online information about gynecologic cancer using validated instruments and (2) to relate the quality of information to its readability. Using the Alexa Rank, we obtained a list of 35 Web pages providing information about 7 gynecologic malignancies. These were assessed using the Health on the Net (HON) seal of approval, the Journal of the American Medical Association (JAMA) benchmarks, and the DISCERN instrument. Flesch readability score was calculated for sections related to symptoms and signs and treatment. Less than 30% of the Web pages displayed the HON seal or achieved all JAMA benchmarks. The majority of the treatment sections were of moderate to high quality according to the DISCERN. There was no significant relationship between the presence of the HON seal and readability. Web pages achieving all JAMA benchmarks were significantly more difficult to read and understand than Web pages that missed any of the JAMA benchmarks. Treatment-related content of moderate to high quality as assessed by the DISCERN had a significantly better readability score than the low-quality content. The online information about gynecologic cancer provided by the most frequently visited Web pages is of variable quality and in general difficult to read and understand. The relationship between the quality and readability remains unclear. Health care providers should direct their patients to reliable material online because patients consider the Internet as an important source of information.

  12. Treatment of Markup in Statistical Machine Translation

    OpenAIRE

    Müller, Mathias

    2017-01-01

    We present work on handling XML markup in Statistical Machine Translation (SMT). The methods we propose can be used to effectively preserve markup (for instance inline formatting or structure) and to place markup correctly in a machine-translated segment. We evaluate our approaches with parallel data that naturally contains markup or where markup was inserted to create synthetic examples. In our experiments, hybrid reinsertion has proven the most accurate method to handle markup, while alignm...

  13. Readability Comparison of Pro- and Anti-Cancer Screening Online Messages in Japan

    Science.gov (United States)

    Okuhara, Tsuyoshi; Ishikawa, Hirono; Okada, Masahumi; Kato, Mio; Kiuchi, Takahiro

    2016-01-01

    Background: Cancer screening rates are lower in Japan than those in western countries. Health professionals publish pro-cancer screening messages on the internet to encourage audiences to undergo cancer screening. However, the information provided is often difficult to read for lay persons. Further, anti-cancer screening activists warn against cancer screening with messages on the Internet. We aimed to assess and compare the readability of pro- and anti-cancer screening online messages in Japan using a measure of readability. Methods: We conducted web searches at the beginning of September 2016 using two major Japanese search engines (Google.jp and Yahoo!.jp). The included websites were classified as “anti”, “pro”, or “neutral” depending on the claims, and “health professional” or “non-health professional” depending on the writers. Readability was determined using a validated measure of Japanese readability. Statistical analysis was conducted using two-way ANOVA. Results: In the total 159 websites analyzed, anti-cancer screening online messages were generally easier to read than pro-cancer screening online messages, Messages written by health professionals were more difficult to read than those written by non-health professionals. Claim × writer interaction was not significant. Conclusion: When health professionals prepare pro-cancer screening materials for publication online, we recommend they check for readability using readability assessment tools and improve text for easy comprehension when necessary. PMID:28125867

  14. The Readability of AAOS Patient Education Materials: Evaluating the Progress Since 2008.

    Science.gov (United States)

    Roberts, Heather; Zhang, Dafang; Dyer, George S M

    2016-09-07

    The Internet has become a major resource for patients; however, patient education materials are frequently written at relatively high levels of reading ability. The purpose of this study was to evaluate the readability of patient education materials on the American Academy of Orthopaedic Surgeons (AAOS) web site. Readability scores were calculated for all patient education articles on the AAOS web site using 5 algorithms: Flesch Reading Ease, Flesch-Kincaid Grade Level, SMOG (Simple Measure of Gobbledygook) Grade, Coleman-Liau Index, and Gunning-Fog Index. The mean readability scores were compared across the anatomic categories to which they pertained. Using a liberal measure of readability, the Flesch-Kincaid Grade Level, 3.9% of articles were written at or below the recommended sixth-grade reading level, and 84% of the articles were written above the eighth-grade reading level. Articles in the present study had a lower mean Flesch-Kincaid Grade Level than those available in 2008 (p readability levels of AAOS articles are higher than generally recommended. Although the mean Flesch-Kincaid Grade Level was lower in the present study than it was in 2008, a need remains to improve the readability of AAOS patient education articles. Ensuring that online patient education materials are written at an appropriate reading grade level would be expected to improve physician-patient communication. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  15. Quality and readability assessment of websites related to recurrent respiratory papillomatosis.

    Science.gov (United States)

    San Giorgi, Michel R M; de Groot, Olivier S D; Dikkers, Frederik G

    2017-10-01

    Recurrent respiratory papillomatosis (RRP) is a rare disease for which a limited number of information sources for patients exist. The role of the Internet in the patient-physician relationship is increasing. More and more patients search for online health information, which should be of good quality and easy readable. The study aim was to investigate the quality and readability of English online health information about RRP. Quality and readability assessment of online information. Relevant information was collected using three different search engines and seven different search terms. Quality was assessed with the DISCERN instrument. The Flesch Reading Ease Score (FRES) and average grade level (AGL) were determined to measure readability of the English websites. Fifty-one English websites were included. The mean DISCERN score of the websites is 28.1 ± 9.7 (poor quality); the mean FRES is 41.3 ± 14.9 (difficult to read); and the mean AGL is 12.6 ± 2.3. The quality and readability of English websites about RRP is alarmingly poor. NA. Laryngoscope, 127:2293-2297, 2017. © 2017 The Authors The Laryngoscope published by Wiley Periodicals, Inc. on behalf of American Laryngological, Rhinological and Otological Society Inc, “The Triological Society” and American Laryngological Association (ALA).

  16. Readability of Spine-Related Patient Education Materials From Leading Orthopedic Academic Centers.

    Science.gov (United States)

    Ryu, Justine H; Yi, Paul H

    2016-05-01

    Cross-sectional analysis of online spine-related patient education materials from leading academic centers. To assess the readability levels of spine surgery-related patient education materials available on the websites of academic orthopedic surgery departments. The Internet is becoming an increasingly popular resource for patient education. Yet many previous studies have found that Internet-based orthopedic-related patient education materials from subspecialty societies are written at a level too difficult for the average American; however, no prior study has assessed the readability of spine surgery-related patient educational materials from leading academic centers. All spine surgery-related articles from the online patient education libraries of the top five US News & World Report-ranked orthopedic institutions were assessed for readability using the Flesch-Kincaid (FK) readability test. Mean readability levels of articles amongst the five academic institutions and articles were compared. We also determined the number of articles with readability levels at or below the recommended sixth- or eight-grade levels. Intraobserver and interobserver reliability of readability assessment were assessed. A total of 122 articles were reviewed. The mean overall FK grade level was 11.4; the difference in mean FK grade level between each department varied significantly (range, 9.3-13.4; P Online patient education materials related to spine from academic orthopedic centers are written at a level too high for the average patient, consistent with spine surgery-related patient education materials provided by the American Academy of Orthopaedic Surgeons and spine subspecialty societies. This study highlights the potential difficulties patients might have in reading and comprehending the information in publicly available education materials related to spine. N/A.

  17. Readability evaluation of Internet-based patient education materials related to the anesthesiology field.

    Science.gov (United States)

    De Oliveira, Gildasio S; Jung, Michael; Mccaffery, Kirsten J; McCarthy, Robert J; Wolf, Michael S

    2015-08-01

    The main objective of the current investigation was to assess the readability of Internet-based patient education materials related to the field of anesthesiology. We hypothesized that the majority of patient education materials would not be written according to current recommended readability grade level. Online patient education materials describing procedures, risks, and management of anesthesia-related topics were identified using the search engine Google (available at www.google.com) using the terms anesthesia, anesthesiology, anesthesia risks, and anesthesia care. Cross-sectional evaluation. None. Assessments of content readability were performed using validated instruments (Flesch-Kincaid Grade Formulae, the Gunning Frequency of Gobbledygook, the New Dale-Chall Test, the Fry graph, and the Flesch Reading Ease score). Ninety-six Web sites containing Internet patient education materials (IPEMs) were evaluated. The median (interquartile range) readability grade level for all evaluated IPEMs was 13.5 (12.0-14.6). All the evaluated documents were classified at a greater readability level than the current recommended readability grade, P Internet-based patient education materials related to the field of anesthesiology are currently written far above the recommended readability grade level. High complexity of written education materials likely limits access of information to millions of American patients. Redesign of online content of Web sites that provide patient education material regarding anesthesia could be an important step in improving access to information for patients with poor health literacy. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Assessing the readability of ClinicalTrials.gov.

    Science.gov (United States)

    Wu, Danny T Y; Hanauer, David A; Mei, Qiaozhu; Clark, Patricia M; An, Lawrence C; Proulx, Joshua; Zeng, Qing T; Vydiswaran, V G Vinod; Collins-Thompson, Kevyn; Zheng, Kai

    2016-03-01

    ClinicalTrials.gov serves critical functions of disseminating trial information to the public and helping the trials recruit participants. This study assessed the readability of trial descriptions at ClinicalTrials.gov using multiple quantitative measures. The analysis included all 165,988 trials registered at ClinicalTrials.gov as of April 30, 2014. To obtain benchmarks, the authors also analyzed 2 other medical corpora: (1) all 955 Health Topics articles from MedlinePlus and (2) a random sample of 100,000 clinician notes retrieved from an electronic health records system intended for conveying internal communication among medical professionals. The authors characterized each of the corpora using 4 surface metrics, and then applied 5 different scoring algorithms to assess their readability. The authors hypothesized that clinician notes would be most difficult to read, followed by trial descriptions and MedlinePlus Health Topics articles. Trial descriptions have the longest average sentence length (26.1 words) across all corpora; 65% of their words used are not covered by a basic medical English dictionary. In comparison, average sentence length of MedlinePlus Health Topics articles is 61% shorter, vocabulary size is 95% smaller, and dictionary coverage is 46% higher. All 5 scoring algorithms consistently rated CliniclTrials.gov trial descriptions the most difficult corpus to read, even harder than clinician notes. On average, it requires 18 years of education to properly understand these trial descriptions according to the results generated by the readability assessment algorithms. Trial descriptions at CliniclTrials.gov are extremely difficult to read. Significant work is warranted to improve their readability in order to achieve CliniclTrials.gov's goal of facilitating information dissemination and subject recruitment. Published by Oxford University Press on behalf of the American Medical Informatics Association 2015. This work is written by US Government

  19. A Mobile Robot for Emergency Operation of Fuel Exchange Machine

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Yongchil; Lee, Sunguk; Kim, Changhoi; Shin, Hochul; Jung, Seungho; Choi, Changhwan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2007-07-01

    A Pressurized Heavy Water Reactor (PHWR) uses a heavy water as the coolant and moderator because it does not attenuate the neutron inside the reactor, which makes it possible to use natural uranium for nuclear fuels. However, since the uranium ratio is too low within the natural uranium, the reactor should be refueled everyday while the reactor is working. For that purpose, there is a fuel exchange machine. However as the time passes by, the durability and reliability become a problem. While the fuel handling machine exchanges the reactor fuel, it can be stuck to the pressure tube attached in the Calandra. Although this kind of situation is rarely happen, it can make the reactor be shutdown for normalizing the operation. Since the refueling is performed while the reactor is working, the radiation level is extremely high and the machine can be located at a high position up to nine meters from the floor, that is, the human worker can not approach the machine, so the fuel handling machine should be released remotely. To cope with this situation, the fuel handling machine has a manual drive mechanism at the rear side of it as shown in the circled images. If the worker can handle these manual drive mechanisms, the fuel handling machine can be released form the pressure tube. The KAERI had developed a long-reach manipulator system with a telescophic mast mechanism which can be deployed in the basement of the reactor room and manipulate the manual lever of the fuel exchange machine. Since the manipulator is located in the basement, there are several problems for its application such that the plug hole should be removed before the operation and the vibration of the mast mechanism make it difficult to locate the end effecter of the manipulator.

  20. A Mobile Robot for Emergency Operation of Fuel Exchange Machine

    International Nuclear Information System (INIS)

    Seo, Yongchil; Lee, Sunguk; Kim, Changhoi; Shin, Hochul; Jung, Seungho; Choi, Changhwan

    2007-01-01

    A Pressurized Heavy Water Reactor (PHWR) uses a heavy water as the coolant and moderator because it does not attenuate the neutron inside the reactor, which makes it possible to use natural uranium for nuclear fuels. However, since the uranium ratio is too low within the natural uranium, the reactor should be refueled everyday while the reactor is working. For that purpose, there is a fuel exchange machine. However as the time passes by, the durability and reliability become a problem. While the fuel handling machine exchanges the reactor fuel, it can be stuck to the pressure tube attached in the Calandra. Although this kind of situation is rarely happen, it can make the reactor be shutdown for normalizing the operation. Since the refueling is performed while the reactor is working, the radiation level is extremely high and the machine can be located at a high position up to nine meters from the floor, that is, the human worker can not approach the machine, so the fuel handling machine should be released remotely. To cope with this situation, the fuel handling machine has a manual drive mechanism at the rear side of it as shown in the circled images. If the worker can handle these manual drive mechanisms, the fuel handling machine can be released form the pressure tube. The KAERI had developed a long-reach manipulator system with a telescophic mast mechanism which can be deployed in the basement of the reactor room and manipulate the manual lever of the fuel exchange machine. Since the manipulator is located in the basement, there are several problems for its application such that the plug hole should be removed before the operation and the vibration of the mast mechanism make it difficult to locate the end effecter of the manipulator

  1. How Readable Are Parenting Books?

    Science.gov (United States)

    Abram, Marie J.; Dowling, William D.

    1979-01-01

    The author's style of writing has implications for the ease with which the written material can be read. Using the Flesch Reading Ease Formula, the mean readability score, the standard deviation, and range are given for 50 parenting books. Discussion suggests how the list might be used by parent educators. (Author)

  2. Readability assessment of online urology patient education materials.

    Science.gov (United States)

    Colaco, Marc; Svider, Peter F; Agarwal, Nitin; Eloy, Jean Anderson; Jackson, Imani M

    2013-03-01

    The National Institutes of Health, American Medical Association, and United States Department of Health and Human Services recommend that patient education materials be written at a fourth to sixth grade reading level to facilitate comprehension. We examined and compared the readability and difficulty of online patient education materials from the American Urological Association and academic urology departments in the Northeastern United States. We assessed the online patient education materials for difficulty level with 10 commonly used readability assessment tools, including the Flesch Reading Ease Score, Flesch-Kincaid Grade Level, Simple Measure of Gobbledygook, Gunning Frequency of Gobbledygook, New Dale-Chall Test, Coleman-Liau index, New Fog Count, Raygor Readability Estimate, FORCAST test and Fry score. Most patient education materials on the websites of these programs were written at or above the eleventh grade reading level. Urological online patient education materials are written above the recommended reading level. They may need to be simplified to facilitate better patient understanding of urological topics. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  3. Pylinguistics: an open source library for readability assessment of texts written in Portuguese

    Directory of Open Access Journals (Sweden)

    Castilhos, S.

    2016-12-01

    Full Text Available Readability assessment is an important task in automatic text simplification that aims identify the text complexity by computing a set of metrics. In this paper, we present the development and assessment of an open source library called Pylinguistics to readability assessment of texts written in Portuguese. Additionally, to illustrate the possibilities of our tool, this work also presents an empirical analysis of readability of Brazilian scientific news dissemination.

  4. Readability of patient education materials in ophthalmology: a single-institution study and systematic review.

    Science.gov (United States)

    Williams, Andrew M; Muir, Kelly W; Rosdahl, Jullia A

    2016-08-03

    Patient education materials should be written at a level that is understandable for patients with low health literacy. The aims of this study are (1) to review the literature on readability of ophthalmic patient education materials and (2) to evaluate and revise our institution's patient education materials about glaucoma using evidence-based guidelines on writing for patients with low health literacy. A systematic search was conducted on the PubMed/MEDLINE database for studies that have evaluated readability level of ophthalmic patient education materials, and the reported readability scores were assessed. Additionally, we collected evidence-based guidelines for writing easy-to-read patient education materials, and these recommendations were applied to revise 12 patient education handouts on various glaucoma topics at our institution. Readability measures, including Flesch-Kincaid Grade Level (FKGL), and word count were calculated for the original and revised documents. The original and revised versions of the handouts were then scored in random order by two glaucoma specialists using the Suitability Assessment of Materials (SAM) instrument, a grading scale used to evaluate suitability of health information materials for patients. Paired t test was used to analyze changes in readability measures, word count, and SAM score between original and revised handouts. Finally, five glaucoma patients were interviewed to discuss the revised materials, and patient feedback was analyzed qualitatively. Our literature search included 13 studies that evaluated a total of 950 educational materials. Among the mean FKGL readability scores reported in these studies, the median was 11 (representing an eleventh-grade reading level). At our institution, handouts' readability averaged a tenth-grade reading level (FKGL = 10.0 ± 1.6), but revising the handouts improved their readability to a sixth-grade reading level (FKGL = 6.4 ± 1.2) (p readability and suitability of

  5. Event detection and exception handling strategies in the ASDEX Upgrade discharge control system

    International Nuclear Information System (INIS)

    Treutterer, W.; Neu, G.; Rapson, C.; Raupp, G.; Zasche, D.; Zehetbauer, T.

    2013-01-01

    Highlights: •Event detection and exception handling is integrated in control system architecture. •Pulse control with local exception handling and pulse supervision with central exception handling are strictly separated. •Local exception handling limits the effect of an exception to a minimal part of the controlled system. •Central Exception Handling solves problems requiring coordinated action of multiple control components. -- Abstract: Thermonuclear plasmas are governed by nonlinear characteristics: plasma operation can be classified into scenarios with pronounced features like L and H-mode, ELMs or MHD activity. Transitions between them may be treated as events. Similarly, technical systems are also subject to events such as failure of measurement sensors, actuator saturation or violation of machine and plant operation limits. Such situations often are handled with a mixture of pulse abortion and iteratively improved pulse schedule reference programming. In case of protection-relevant events, however, the complexity of even a medium-sized device as ASDEX Upgrade requires a sophisticated and coordinated shutdown procedure rather than a simple stop of the pulse. The detection of events and their intelligent handling by the control system has been shown to be valuable also in terms of saving experiment time and cost. This paper outlines how ASDEX Upgrade's discharge control system (DCS) detects events and handles exceptions in two stages: locally and centrally. The goal of local exception handling is to limit the effect of an unexpected or asynchronous event to a minimal part of the controlled system. Thus, local exception handling facilitates robustness to failures but keeps the decision structures lean. A central state machine deals with exceptions requiring coordinated action of multiple control components. DCS implements the state machine by means of pulse schedule segments containing pre-programmed waveforms to define discharge goal and control

  6. Event detection and exception handling strategies in the ASDEX Upgrade discharge control system

    Energy Technology Data Exchange (ETDEWEB)

    Treutterer, W., E-mail: Wolfgang.Treutterer@ipp.mpg.de; Neu, G.; Rapson, C.; Raupp, G.; Zasche, D.; Zehetbauer, T.

    2013-10-15

    Highlights: •Event detection and exception handling is integrated in control system architecture. •Pulse control with local exception handling and pulse supervision with central exception handling are strictly separated. •Local exception handling limits the effect of an exception to a minimal part of the controlled system. •Central Exception Handling solves problems requiring coordinated action of multiple control components. -- Abstract: Thermonuclear plasmas are governed by nonlinear characteristics: plasma operation can be classified into scenarios with pronounced features like L and H-mode, ELMs or MHD activity. Transitions between them may be treated as events. Similarly, technical systems are also subject to events such as failure of measurement sensors, actuator saturation or violation of machine and plant operation limits. Such situations often are handled with a mixture of pulse abortion and iteratively improved pulse schedule reference programming. In case of protection-relevant events, however, the complexity of even a medium-sized device as ASDEX Upgrade requires a sophisticated and coordinated shutdown procedure rather than a simple stop of the pulse. The detection of events and their intelligent handling by the control system has been shown to be valuable also in terms of saving experiment time and cost. This paper outlines how ASDEX Upgrade's discharge control system (DCS) detects events and handles exceptions in two stages: locally and centrally. The goal of local exception handling is to limit the effect of an unexpected or asynchronous event to a minimal part of the controlled system. Thus, local exception handling facilitates robustness to failures but keeps the decision structures lean. A central state machine deals with exceptions requiring coordinated action of multiple control components. DCS implements the state machine by means of pulse schedule segments containing pre-programmed waveforms to define discharge goal and control

  7. The readability and suitability of sexual health promotion leaflets.

    Science.gov (United States)

    Corcoran, Nova; Ahmad, Fatuma

    2016-02-01

    To investigate the readability and suitability of sexual health promotion leaflets. Application of SMOG, FRY and SAM tests to assess the readability and suitability of a selection of sexual health leaflets. SMOG and FRY scores illustrate an average reading level of grade 9. SAM scores indicate that 59% of leaflets are superior in design and 41% are average in design. Leaflets generally perform well in the categories of content, literacy demand, typography and layout. They perform poorly in use of graphics, learning stimulation/motivation and cultural appropriateness. Sexual health leaflets have a reading level that is too high. Leaflets perform well on the suitability scores indicating they are reasonably suitable. There are a number of areas where sexual health leaflets could improve their design. Numerous practical techniques are suggested for improving the readability and suitability of sexual health leaflets. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. A Look at Technologies Vis-a-vis Information Handling Techniques.

    Science.gov (United States)

    Swanson, Rowena W.

    The paper examines several ideas for information handling implemented with new technologies that suggest directions for future development. These are grouped under the topic headings: Handling Large Data Banks, Providing Personalized Information Packages, Providing Information Specialist Services, and Expanding Man-Machine Interaction. Guides in…

  9. Consent information leaflets – readable or unreadable?

    Science.gov (United States)

    Graham, Caroline; Reynard, John M; Turney, Benjamin W

    2016-01-01

    Objective The objective of this article is to assess the readability of leaflets about urological procedures provided by the British Association of Urological Surgeons (BAUS) to evaluate their suitability for providing information. Methods Information leaflets were assessed using three measures of readability: Flesch Reading Ease, Flesch-Kincaid and Simple Measure of Gobbledygook (SMOG) grade formulae. The scores were compared with national literacy statistics. Results Relatively good readability was demonstrated using the Flesch Reading Ease (53.4–60.1) and Flesch-Kincaid Grade Level (6.5–7.6) methods. However, the average SMOG index (14.0–15.0) for each category suggests that the majority of the leaflets are written above the reading level of an 18-year-old. Using national literacy statistics, at least 43% of the population will have significant difficultly understanding the majority of these leaflets. Conclusions The results suggest that comprehension of the leaflets provided by the BAUS is likely to be poor. These leaflets may be used as an adjunct to discussion but it is essential to ensure that all the information necessary to make an informed decision has been conveyed in a way that can be understood by the patient. PMID:27867520

  10. Readability of Online Patient Educational Resources Found on NCI-Designated Cancer Center Web Sites.

    Science.gov (United States)

    Rosenberg, Stephen A; Francis, David; Hullett, Craig R; Morris, Zachary S; Fisher, Michael M; Brower, Jeffrey V; Bradley, Kristin A; Anderson, Bethany M; Bassetti, Michael F; Kimple, Randall J

    2016-06-01

    The NIH and Department of Health & Human Services recommend online patient information (OPI) be written at a sixth grade level. We used a panel of readability analyses to assess OPI from NCI-Designated Cancer Center (NCIDCC) Web sites. Cancer.gov was used to identify 68 NCIDCC Web sites from which we collected both general OPI and OPI specific to breast, prostate, lung, and colon cancers. This text was analyzed by 10 commonly used readability tests: the New Dale-Chall Readability Formula, Flesch Reading Ease scale, Flesch-Kinaid Grade Level, FORCAST scale, Fry Readability Graph, Simple Measure of Gobbledygook test, Gunning Frequency of Gobbledygook index, New Fog Count, Raygor Readability Estimate Graph, and Coleman-Liau Index. We tested the hypothesis that the readability of NCIDCC OPI was written at the sixth grade level. Secondary analyses were performed to compare readability of OPI between comprehensive and noncomprehensive centers, by region, and to OPI produced by the American Cancer Society (ACS). A mean of 30,507 words from 40 comprehensive and 18 noncomprehensive NCIDCCs was analyzed (7 nonclinical and 3 without appropriate OPI were excluded). Using a composite grade level score, the mean readability score of 12.46 (ie, college level: 95% CI, 12.13-12.79) was significantly greater than the target grade level of 6 (middle-school: Preadability metrics (P<.05). ACS OPI provides easier language, at the seventh to ninth grade level, across all tests (P<.01). OPI from NCIDCC Web sites is more complex than recommended for the average patient. Copyright © 2016 by the National Comprehensive Cancer Network.

  11. Readability assessment of package inserts of biological medicinal products from the European medicines agency website.

    Science.gov (United States)

    Piñero-López, Ma Ángeles; Modamio, Pilar; Lastra, Cecilia F; Mariño, Eduardo L

    2014-07-01

    Package inserts that accompany medicines are a common source of information aimed at patients and should match patient abilities in terms of readability. Our objective was to determine the degree of readability of the package inserts for biological medicinal products commercially available in 2007 and compare them with the readability of the same package inserts in 2010. A total of 33 package inserts were selected and classified into five groups according to the type of medicine: monoclonal antibody-based products, cytokines, therapeutic enzymes, recombinant blood factors and other blood-related products, and recombinant hormones. The package inserts were downloaded from the European Medicines Agency website in 2007 and 2010. Readability was evaluated for the entire text of five of the six sections of the package inserts and for the 'Annex' when there was one. Three readability formulas were used: SMOG (Simple Measure of Gobbledygook) grade, Flesh-Kincaid grade level, and Szigriszt's perspicuity index. No significant differences were found between the readability results for the 2007 package inserts and those from 2010 according to any of the three readability indices studied (p>0.05). However, there were significant differences (preadability scores of the sections of the package inserts in both 2007 and 2010. The readability of the package inserts was above the recommended sixth grade reading level (ages 11-12) and may lead to difficulties of understanding for people with limited literacy. All the sections should be easy to read and, therefore, the readability of the medicine package inserts studied should be improved.

  12. The Readability of Information Literacy Content on Academic Library Web Sites

    Science.gov (United States)

    Lim, Adriene

    2010-01-01

    This article reports on a study addressing the readability of content on academic libraries' Web sites, specifically content intended to improve users' information literacy skills. Results call for recognition of readability as an evaluative component of text in order to better meet the needs of diverse user populations. (Contains 8 tables.)

  13. Readability in reading materials selection and coursebook design for college English in China

    OpenAIRE

    Lu, Zhongshe

    2002-01-01

    This thesis studies the application of readability in reading materials selection and coursebook design for college English in an EFL context in China. Its aim is to develop rationales which coursebook writers can utilise in selecting materials as texts and as a basis for designing tasks. This study, through a combination of quantitative and qualitative research methods, argues that readability is applicable in the EFL Chinese context, and readability plays a important role in determining...

  14. Using readability, comprehensibility and lexical coverage to ...

    African Journals Online (AJOL)

    experience academic difficulty in technical subjects such as Accounting. Davison and ...... The readability of managerial accounting and financial management textbooks. .... Principles and Practice in Second Language Acquisition. Available.

  15. A readability comparison of anti- versus pro-influenza vaccination online messages in Japan

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Okuhara

    2017-06-01

    When health professionals prepare pro-influenza vaccination materials for publication online, we recommend they check for readability using readability assessment tools and improve the text for easy reading if necessary.

  16. Readability of the web: a study on 1 billion web pages

    NARCIS (Netherlands)

    de Heus, Marije; Hiemstra, Djoerd

    We have performed a readability study on more than 1 billion web pages. The Automated Readability Index was used to determine the average grade level required to easily comprehend a website. Some of the results are that a 16-year-old can easily understand 50% of the web and an 18-year old can easily

  17. Readability of HIV/AIDS educational materials: the role of the medium of communication, target audience, and producer characteristics.

    Science.gov (United States)

    Wells, J A

    1994-12-01

    The reading difficulty of many HIV/AIDS brochures and pamphlets limits their effectiveness. This analysis addresses correlates of readability in 136 HIV/AIDS educational items. Readability is measured using the SMOG Index. The medium of communication is significantly related to readability: comic books and brochures are, on average, more readable than books and pamphlets (10.9 versus 11.9). The target audience also differentiates readability. Materials for HIV antibody test seekers, the general community, and sexually active adults have a more difficult reading grade, averaging 12.1, whereas materials for ethnic minorities average a more readable 9.2. The producer organization's type and location are unrelated to readability, but an AIDS-specific organizational focus correlates with better readability (grade 10.8 vs. 11.8). These findings remain significant in multivariate analysis. The results indicate that brochures and comics are more likely to be comprehended by low-literacy populations, that an understanding of the literacy of target audiences is needed to produce materials with appropriate reading levels, and that policies to influence producer organizations may result in the creation of more readable materials.

  18. Using Readability Tests to Improve the Accuracy of Evaluation Documents Intended for Low-Literate Participants

    Science.gov (United States)

    Kouame, Julien B.

    2010-01-01

    Background: Readability tests are indicators that measure how easy a document can be read and understood. Simple, but very often ignored, readability statistics cannot only provide information about the level of difficulty of the readability of particular documents but also can increase an evaluator's credibility. Purpose: The purpose of this…

  19. Web-based information on the treatment of oral leukoplakia - quality and readability.

    Science.gov (United States)

    Wiriyakijja, Paswach; Fedele, Stefano; Porter, Stephen; Ni Riordain, Richeal

    2016-09-01

    To categorise the content and assess the quality and readability of the online information regarding the treatment for oral leukoplakia. An online search using the term 'leukoplakia treatment' was carried out on 8th June 2015 using the Google search engine. The content, quality and readability of the first 100 sites were explored. The quality of the web information was assessed using the following tools, the DISCERN instrument and the Journal of the American Medical Association (JAMA) benchmarks for website analysis and the HON seal. Readability was assessed via the Flesch Reading Ease Score. The search strategy generated 357 000 sites on the Google search engine. Due to duplicate links, non-operating links and irrelevant links, a total of 47 of the first 100 websites were included in this study. The mean overall rating achieved by included websites using the DISCERN instrument was 2.3. With regard to the JAMA benchmarks, the vast majority of examined websites (95.7%) completely fulfilled the disclosure benchmark and less than 50% of included websites met the three remaining criteria. A mean total readability score of 47.5 was recorded with almost 90% of websites having a readability level ranging from fairly difficult to very difficult. Based on this study, the online health information regarding oral leukoplakia has challenging readability with content of questionable accuracy. As patients often search for health information online, it would be prudent for clinicians to highlight the caution with which online information should be interpreted. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Assessment of readability, understandability, and completeness of pediatric hospital medicine discharge instructions.

    Science.gov (United States)

    Unaka, Ndidi I; Statile, Angela; Haney, Julianne; Beck, Andrew F; Brady, Patrick W; Jerardi, Karen E

    2017-02-01

    The average American adult reads at an 8th-grade level. Discharge instructions written above this level might increase the risk of adverse outcomes for children as they transition from hospital to home. We conducted a cross-sectional study at a large urban academic children's hospital to describe readability levels, understandability scores, and completeness of written instructions given to families at hospital discharge. Two hundred charts for patients discharged from the hospital medicine service were randomly selected for review. Written discharge instructions were extracted and scored for readability (Fry Readability Scale [FRS]), understandability (Patient Education Materials Assessment Tool [PEMAT]), and completeness (5 criteria determined by consensus). Descriptive statistics enumerated the distribution of readability, understandability, and completeness of written discharge instructions. Of the patients included in the study, 51% were publicly insured. Median age was 3.1 years, and median length of stay was 2.0 days. The median readability score corresponded to a 10th-grade reading level (interquartile range, 8-12; range, 1-13). Median PEMAT score was 73% (interquartile range, 64%-82%; range, 45%-100%); 36% of instructions scored below 70%, correlating with suboptimal understandability. The diagnosis was described in only 33% of the instructions. Although explicit warning signs were listed in most instructions, 38% of the instructions did not include information on the person to contact if warning signs developed. Overall, the readability, understandability, and completeness of discharge instructions were subpar. Efforts to improve the content of discharge instructions may promote safe and effective transitions home. Journal of Hospital Medicine 2017;12:98-101. © 2017 Society of Hospital Medicine.

  1. A Software Application for Assessing Readability in the Japanese EFL Context

    Science.gov (United States)

    Ozasa, Toshiaki; Weir, George R. S.; Fukui, Masayasu

    2010-01-01

    We have been engaged in developing a readability index and its application software attuned for Japanese EFL learners. The index program, Ozasa-Fukui Year Level Program, Ver. 1.0, was used in developing the readability metric Ozasa-Fukui Year Level Index but tended to assume a high level of computer knowledge in its users. As a result, the…

  2. Readability of Air Force Publications: A Criterion Referenced Evaluation. Final Report.

    Science.gov (United States)

    Hooke, Lydia R.; And Others

    In a study of the readability of Air Force regulations, the writer-estimated reading grade level (RGL) for each regulation was rechecked by using the FORCAST readability formula. In four of the seven cases, the regulation writers underestimated the RGL of their regulation by more than one grade level. None of the writers produced a document with…

  3. Readability of Questionnaires Assessing Listening Difficulties Associated with (Central) Auditory Processing Disorders

    Science.gov (United States)

    Atcherson, Samuel R.; Richburg, Cynthia M.; Zraick, Richard I.; George, Cassandra M.

    2013-01-01

    Purpose: Eight English-language, student- or parent proxy-administered questionnaires for (central) auditory processing disorders, or (C)APD, were analyzed for readability. For student questionnaires, readability levels were checked against the approximate reading grade levels by intended administration age per the questionnaires' developers. For…

  4. Varying Readability of Science-Based Text in Elementary Readers: Challenges for Teachers

    Science.gov (United States)

    Gallagher, Tiffany L.; Fazio, Xavier; Gunning, Thomas G.

    2012-01-01

    This investigation compared readability formulae to publishers' identified reading levels in science-based elementary readers. Nine well-established readability indices were calculated and comparisons were made with the publishers' identified grade designations and between different genres of text. Results revealed considerable variance among the…

  5. Readability of Trauma-Related Patient Education Materials From the American Academy of Orthopaedic Surgeons.

    Science.gov (United States)

    Eltorai, Adam E M; P Thomas, Nathan; Yang, Heejae; Daniels, Alan H; Born, Christopher T

    2016-02-01

    According to the american medical association (AMA) and the national institutes of health (NIH), the recommended readability of patient education materials should be no greater than a sixth-grade reading level. The online patient education information produced by the american academy of orthopaedic surgeons (AAOS) may be too complicated for some patients to understand. This study evaluated whether the AAOS's online trauma-related patient education materials meet recommended readability guidelines for medical information. Ninety-nine articles from the "Broken Bones and Injuries" section of the AAOS-produced patient education website, orthoinfo.org, were analyzed for grade level readability using the Flesch-Kincaid formula, a widely-used and validated tool to evaluate the text reading level. Results for each webpage were compared to the AMA/NIH recommended sixth-grade reading level and the average reading level of U.S. adults (eighth-grade). The mean (SD) grade level readability for all patient education articles was 8.8 (1.1). All but three of the articles had a readability score above the sixth-grade level. The readability of the articles exceeded this level by an average of 2.8 grade levels (95% confidence interval, 2.6 - 3.0; P reading skill level of U.S. adults (eighth grade) by nearly an entire grade level (95% confidence interval, 0.6-1.0; P education website have readability levels that may make comprehension difficult for a substantial portion of the patient population.

  6. Sense and readability: participant information sheets for research studies.

    Science.gov (United States)

    Ennis, Liam; Wykes, Til

    2016-02-01

    Informed consent in research is partly achieved through the use of information sheets. There is a perception however that these information sheets are long and complex. The recommended reading level for patient information is grade 6, or 11-12 years old. To investigate whether the readability of participant information sheets has changed over time, whether particular study characteristics are related to poorer readability and whether readability and other study characteristics are related to successful study recruitment. Method: We obtained 522 information sheets from the UK National Institute for Health Research Clinical Research Network: Mental Health portfolio database and study principal investigators. Readability was assessed with the Flesch reading index and the Grade level test. Information sheets increased in length over the study period. The mean grade level across all information sheets was 9.8, or 15-16 years old. A high level of patient involvement was associated with more recruitment success and studies involving pharmaceutical or device interventions were the least successful. The complexity of information sheets had little bearing on successful recruitment. Information sheets are far more complex than the recommended reading level of grade 6 for patient information. The disparity may be exacerbated by an increasing focus on legal content. Researchers would benefit from clear guidance from ethics committees on writing succinctly and accessibly and how to balance the competing legal issues with the ability of participants to understand what a study entails. © The Royal College of Psychiatrists 2016.

  7. [Systematic analysis of the readability of patient information on the websites of clinics for plastic surgery].

    Science.gov (United States)

    Esfahani, B Janghorban; Faron, A; Roth, K S; Schaller, H-E; Medved, F; Lüers, J-C

    2014-12-01

    The Internet is becoming increasing-ly important as a source of information for patients in medical issues. However, many patients have problems to adequately understand texts, especially with medical content. A basic requirement to understand a written text is the read-ability of a text. The aim of the present study was to examine texts on the websites of German -plastic-surgical hospitals with patient information regarding their readability. In this study, the read-ability of texts of 27 major departments of plastic and Hand surgery in Germany was systematically analysed using 5 recognised readability indices. First, texts were searched based on 20 representative key words and themes. Thereafter, texts were assigned to one of 3 major themes in order to enable statistical analysis. In addition to the 5 readability indices, further objective text parameters were also recorded. Overall, 288 texts were found for analyzation. Most articles were found on the topic of "handsurgery" (n=124), less were found for "facial plastic surgery" (n=80) and "flaps, breast and reconstructive surgery" (n=84). Consistently, all readability indices showed a poor readability for the vast majority of analysed texts with the text appearing readable only for readers with a higher educational level. No significant differences in readability were found between the 3 major themes. Especially in the communication of medical information, it is important to consider the knowledge and education of the addressee. The texts studied consistently showed a readability that is understandable only for academics. Thus, a large part of the intended target group is probably not reached. In order to adequately deliver online information material, a revision of the analysed internet texts appears to be recommendable. © Georg Thieme Verlag KG Stuttgart · New York.

  8. The readability of scientific texts is decreasing over time

    Science.gov (United States)

    2017-01-01

    Clarity and accuracy of reporting are fundamental to the scientific process. Readability formulas can estimate how difficult a text is to read. Here, in a corpus consisting of 709,577 abstracts published between 1881 and 2015 from 123 scientific journals, we show that the readability of science is steadily decreasing. Our analyses show that this trend is indicative of a growing use of general scientific jargon. These results are concerning for scientists and for the wider public, as they impact both the reproducibility and accessibility of research findings. PMID:28873054

  9. Simultaneous scheduling of machines and mobile robots

    DEFF Research Database (Denmark)

    Dang, Vinh Quang; Nielsen, Izabela Ewa

    2013-01-01

    This paper deals with the problem of simultaneously scheduling machines and a number of autonomous mobile robots in a flexible manufacturing system (FMS). Besides capability of transporting materials between machines, the considered mobile robots are different from other material handling devices...

  10. Readability of Patient Education Materials in Hand Surgery and Health Literacy Best Practices for Improvement.

    Science.gov (United States)

    Hadden, Kristie; Prince, Latrina Y; Schnaekel, Asa; Couch, Cory G; Stephenson, John M; Wyrick, Theresa O

    2016-08-01

    This study aimed to update a portion of a 2008 study of patient education materials from the American Society for Surgery of the Hand Web site with new readability results, to compare the results to health literacy best practices, and to make recommendations to the field for improvement. A sample of 77 patient education documents were downloaded from the American Society for Surgery of the Hand Web site, handcare.org, and assessed for readability using 4 readability tools. Mean readability grade-level scores were derived. Best practices for plain language for written health materials were compiled from 3 government agency sources. The mean readability of the 77 patient education documents in the study was 9.3 grade level. This reading level is reduced from the previous study in 2008 in which the overall mean was 10.6; however, the current sample grade level still exceeds recommended readability according to best practices. Despite a small body of literature on the readability of patient education materials related to hand surgery and other orthopedic issues over the last 7 years, readability was not dramatically improved in our current sample. Using health literacy as a framework, improvements in hand surgery patient education may result in better understanding and better outcomes for patients seeing hand surgeons. Improved understanding of patient education materials related to hand surgery may improve preventable negative outcomes that are clinically significant as well as contribute to improved quality of life for patients. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  11. Can Readability Formulas Be Used to Successfully Gauge Difficulty of Reading Materials?

    Science.gov (United States)

    Begeny, John C.; Greene, Diana J.

    2014-01-01

    A grade level of reading material is commonly estimated using one or more readability formulas, which purport to measure text difficulty based on specified text characteristics. However, there is limited direction for teachers and publishers regarding which readability formulas (if any) are appropriate indicators of actual text difficulty. Because…

  12. A Comparison of Readability in Science-Based Texts: Implications for Elementary Teachers

    Science.gov (United States)

    Gallagher, Tiffany; Fazio, Xavier; Ciampa, Katia

    2017-01-01

    Science curriculum standards were mapped onto various texts (literacy readers, trade books, online articles). Statistical analyses highlighted the inconsistencies among readability formulae for Grades 2-6 levels of the standards. There was a lack of correlation among the readability measures, and also when comparing different text sources. Online…

  13. Machine learning in geosciences and remote sensing

    Directory of Open Access Journals (Sweden)

    David J. Lary

    2016-01-01

    Full Text Available Learning incorporates a broad range of complex procedures. Machine learning (ML is a subdivision of artificial intelligence based on the biological learning process. The ML approach deals with the design of algorithms to learn from machine readable data. ML covers main domains such as data mining, difficult-to-program applications, and software applications. It is a collection of a variety of algorithms (e.g. neural networks, support vector machines, self-organizing map, decision trees, random forests, case-based reasoning, genetic programming, etc. that can provide multivariate, nonlinear, nonparametric regression or classification. The modeling capabilities of the ML-based methods have resulted in their extensive applications in science and engineering. Herein, the role of ML as an effective approach for solving problems in geosciences and remote sensing will be highlighted. The unique features of some of the ML techniques will be outlined with a specific attention to genetic programming paradigm. Furthermore, nonparametric regression and classification illustrative examples are presented to demonstrate the efficiency of ML for tackling the geosciences and remote sensing problems.

  14. Readability levels of health pamphlets distributed in hospitals and health centres in Athens, Greece.

    Science.gov (United States)

    Kondilis, B K; Akrivos, P D; Sardi, T A; Soteriades, E S; Falagas, M E

    2010-10-01

    Health literacy is important in the medical and social sciences due to its impact on behavioural and health outcomes. Nevertheless, little is known about it in Greece, including patients' level of understanding health brochures and pamphlets distributed in Greek hospitals and clinics. Observational study in the greater metropolitan area of Athens, Greece. Pamphlets and brochures written in the Greek language were collected from 17 hospitals and healthcare centres between the spring and autumn of 2006. Readability of pamphlets using the Flesch-Kincaid, Simple Measure of Gobbledygook (SMOG) and Fog methods was calculated based on a Greek readability software. Out of 70 pamphlets collected from 17 hospitals, 37 pamphlets met the criteria for the study. The average readability level of all scanned pamphlets was ninth to 10th grade, corresponding to a readability level of 'average'. A highly significant difference (PPamphlets from private hospitals were one grade more difficult than those from public hospitals. Approximately 43.7% of the Greek population aged ≥20 years would not be able to comprehend the available pamphlets, which were found to have an average readability level of ninth to 10th grade. Further research examining readability levels in the context of health literacy in Greece is warranted. This effort paves the way for additional research in the field of readability levels of health pamphlets in the Greek language, the sources of health information, and the level of understanding of key health messages by the population. Copyright © 2010 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  15. Readability of patient information and consent documents in rheumatological studies

    DEFF Research Database (Denmark)

    Hamnes, Bente; van Eijk-Hustings, Yvonne; Primdahl, Jette

    2016-01-01

    BACKGROUND: Before participation in medical research an informed consent must be obtained. This study investigates whether the readability of patient information and consent documents (PICDs) corresponds to the average educational level of participants in rheumatological studies in the Netherlands......, Denmark, and Norway. METHODS: 24 PICDs from studies were collected and readability was assessed independently using the Gunning's Fog Index (FOG) and Simple Measure of Gobbledygook (SMOG) grading. RESULTS: The mean score for the FOG and SMOG grades were 14.2 (9.0-19.0) and 14.2 (12-17) respectively....... The mean FOG and SMOG grades were 12.7 and 13.3 in the Dutch studies, 15.0 and 14.9 in the Danish studies, and 14.6 and 14.3 in the Norwegian studies, respectively. Out of the 2865 participants, more than 57 % had a lower educational level than the highest readability score calculated in the individual...

  16. Multi Canister Overpack (MCO) Handling Machine Trolley Seismic Uplift Constraint Design Loads

    International Nuclear Information System (INIS)

    SWENSON, C.E.

    2000-01-01

    The MCO Handling Machine (MHM) trolley moves along the top of the MHM bridge girders on east-west oriented rails. To prevent trolley wheel uplift during a seismic event, passive uplift constraints are provided as shown in Figure 1-1. North-south trolley wheel movement is prevented by flanges on the trolley wheels. When the MHM is positioned over a Multi-Canister Overpack (MCO) storage tube, east-west seismic restraints are activated to prevent trolley movement during MCO handling. The active seismic constraints consist of a plunger, which is inserted into slots positioned along the tracks as shown in Figure 1-1. When the MHM trolley is moving between storage tube positions, the active seismic restraints are not engaged. The MHM has been designed and analyzed in accordance with ASME NOG-1-1995. The ALSTHOM seismic analysis (Reference 3) reported seismic uplift restraint loading and EDERER performed corresponding structural calculations. The ALSTHOM and EDERER calculations were performed with the east-west seismic restraints activated and the uplift restraints experiencing only vertical loading. In support of development of the CSB Safety Analysis Report (SAR), an evaluation of the MHM seismic response was requested for the case where the east-west trolley restraints are not engaged. For this case, the associated trolley movements would result in east-west lateral loads on the uplift constraints due to friction, as shown in Figure 1-2. During preliminary evaluations, questions were raised as to whether the EDERER calculations considered the latest ALSTHOM seismic analysis loads (See NCR No. 00-SNFP-0008, Reference 5). Further evaluation led to the conclusion that the EDERER calculations used appropriate vertical loading, but the uplift restraints would need to be re-analyzed and modified to account for lateral loading. The disposition of NCR 00-SNFP-0008 will track the redesign and modification effort. The purpose of this calculation is to establish bounding seismic

  17. Readability assessment of online thyroid surgery patient education materials.

    Science.gov (United States)

    Patel, Chirag R; Cherla, Deepa V; Sanghvi, Saurin; Baredes, Soly; Eloy, Jean Anderson

    2013-10-01

    Published guidelines recommend written health information be written at or below the sixth-grade level. We evaluate the readability of online materials related to thyroid surgery. Thyroid surgery materials were evaluated using Flesch Reading Ease Score (FRES), Flesch Kincaid Grade Level (FKGL), Gunning Frequency of Gobbledygook (GFOG), and Simple Measure of Gobbledygook (SMOG). Thirty-one documents were evaluated. FRES scores ranged from 29.3 to 67.8 (possible range = 0 to 100), and averaged 50.5. FKGL ranged from 6.9 to 14.9 (possible range = 3 to 12), and averaged 10.4. SMOG scores ranged from 11.8 to 14.5 (possible range = 3 to 19), and averaged 13.0. GFOG scores ranged from 10.6 to 18.0 (possible range = 3 to 19), and averaged 13.5. Readability scores for online thyroid surgery materials are higher (i.e., more difficult) than the recommended levels. However, readability is only one aspect of comprehension. Written information should be designed with that fact in mind. Copyright © 2013 Wiley Periodicals, Inc.

  18. Analysis of the readability of patient education materials from surgical subspecialties.

    Science.gov (United States)

    Hansberry, David R; Agarwal, Nitin; Shah, Ravi; Schmitt, Paul J; Baredes, Soly; Setzen, Michael; Carmel, Peter W; Prestigiacomo, Charles J; Liu, James K; Eloy, Jean Anderson

    2014-02-01

    Patients are increasingly using the Internet as a source of information on medical conditions. Because the average American adult reads at a 7th- to 8th-grade level, the National Institutes of Health recommend that patient education material be written between a 4th- and 6th-grade level. In this study, we assess and compare the readability of patient education materials on major surgical subspecialty Web sites relative to otolaryngology. Descriptive and correlational design. Patient education materials from 14 major surgical subspecialty Web sites (American Society of Colon and Rectal Surgeons, American Association of Endocrine Surgeons, American Society of General Surgeons, American Society for Metabolic and Bariatric Surgery, American Association of Neurological Surgeons, American Congress of Obstetricians and Gynecologists, American Academy of Ophthalmology, American Academy of Orthopedic Surgeons, American Academy of Otolaryngology-Head and Neck Surgery, American Pediatric Surgical Association, American Society of Plastic Surgeons, Society for Thoracic Surgeons, and American Urological Association) were downloaded and assessed for their level of readability using 10 widely accepted readability scales. The readability level of patient education material from all surgical subspecialties was uniformly too high. Average readability levels across all subspecialties ranged from the 10th- to 15th-grade level. Otolaryngology and other surgical subspecialties Web sites have patient education material written at an education level that the average American may not be able to understand. To reach a broader population of patients, it might be necessary to rewrite patient education material at a more appropriate level. N/A. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  19. Readability of pediatric otolaryngology information by children's hospitals and academic institutions.

    Science.gov (United States)

    Wong, Kevin; Levi, Jessica R

    2017-04-01

    Evaluate the readability of pediatric otolaryngology-related patient education materials from leading online sources. Cross-sectional analysis. All pediatric otolaryngology-related articles from the online patient health libraries of the top 10 US News & World Report-ranked children's hospitals, top 5 Doximity-ranked pediatric otolaryngology fellowships, and the American Academy of Otolaryngology-Head and Neck Surgery were collected. Each article was copied in plain text format into a blank document. Web page navigation, appointment information, references, author information, appointment information, acknowledgements, and disclaimers were removed. Follow-up editing was also performed to remove paragraph breaks, colons, semicolons, numbers, percentages, and bullets. Readability grade was calculated using the Flesch-Kincaid Grade Level, Flesch Reading Ease Score, Gunning-Fog Index, Coleman-Liau Index, Automated Readability Index, and Simple Measure of Gobbledygook. Intraobserver and interobserver reliability were assessed. A total of 502 articles were analyzed. Intraobserver and interobserver reliability were both excellent, with an intraclass correlation coefficient of 0.99 and 0.96, respectively. The average readability grade across all authorships and readability assessments exceeded the reading ability of the average American adult. Only 142 articles (28.3%) were written at or below the reading ability of the average American adult, whereas the remaining 360 articles (71.7%) were written above the reading level of the average adult. Current online health information related to pediatric otolaryngology may be too difficult for the average reader to understand. Revisions may be necessary for current materials to benefit a larger readership. NA Laryngoscope, 127:E138-E144, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  20. Readability of patient education materials available at the point of care.

    Science.gov (United States)

    Stossel, Lauren M; Segar, Nora; Gliatto, Peter; Fallar, Robert; Karani, Reena

    2012-09-01

    Many patient education materials (PEMs) available on the internet are written at high school or college reading levels, rendering them inaccessible to the average US resident, who reads at or below an 8(th) grade level. Currently, electronic health record (EHR) providers partner with companies that produce PEMs, allowing clinicians to access PEMs at the point of care. To assess the readability of PEMs provided by a popular EHR vendor as well as the National Library of Medicine (NLM). We included PEMs from Micromedex, EBSCO, and MedlinePlus. Micromedex and EBSCO supply PEMs to Meditech, a popular EHR supplier in the US. MedlinePlus supplies the NLM. These PEM databases have high market penetration and accessibility. Grade reading level of the PEMs was calculated using three validated indices: Simple Measure of Gobbledygook (SMOG), Gunning Fog (GFI), and Flesch-Kincaid (FKI). The percentage of documents above target readability and average readability scores from each database were calculated. We randomly sampled 100 disease-matched PEMs from three databases (n = 300 PEMs). Depending on the readability index used, 30-100% of PEMs were written above the 8(th) grade level. The average reading level for MedlinePlus, EBSCO, and Micromedex PEMs was 10.2 (1.9), 9.7 (1.3), and 8.6 (0.9), respectively (p ≤ 0.000) as estimated by the GFI. Estimates of readability using SMOG and FKI were similar. The majority of PEMS available through the NLM and a popular EHR were written at reading levels considerably higher than that of the average US adult.

  1. The Readability of Malaysian English Children Books: A Multilevel Analysis

    Directory of Open Access Journals (Sweden)

    Adlina Ismail

    2016-11-01

    Full Text Available These days, there are more English books for children published by local publishers in Malaysia. It is a positive development because the books will be more accessible to the children. However, the books have never been studied and evaluated in depth yet. One important factor in assessing reading materials is readability. Readability determines whether a text is easy or difficult to understand and a balanced mix of both can promote learning and language development. Various researchers mentioned a multilevel framework of discourse that any language assessment on a text should take into account. The levels that were proposed were word, syntax, textbase, situation model and genre and rhetorical structures. Traditional readability measures such as Flesh Reading Ease Formula, Gunning Readability Index, Fog Count, and Fry Grade Level are not able to address the multilevel because they are based on shallow variables. In contrast, Coh-metrix TERA provided five indices that are correlated to grade level and aligned to the multilevel framework. This study analyzed ten Malaysian English chapter books for children using this Coh-metrix TERA. The result revealed that the Malaysian English children books were easy in shallow level but there was a possible difficulty in textbase and situation model level because of the lack of cohesion. In conclusion, more attention should be given on deeper level of text rather than just word and syntax level.

  2. Readability of Healthcare Literature for Hepatitis B and C.

    Science.gov (United States)

    Meillier, Andrew; Patel, Shyam; Al-Osaimi, Abdullah M S

    2015-12-01

    Patients increasingly use the Internet for educational material concerning health and diseases. This information can be utilized to teach the population of hepatitis B and C if properly written at the necessary grade level of the intended patient population. We explored the readability of online resources concerning hepatitis B and C. Google searches were performed for "Hepatitis B" and "Hepatitis C." The Internet resources that were intended for patient education were used with specific exclusions. Articles were taken from 19 and 23 different websites focusing on the symptoms, diagnosis, and treatment of hepatitis B and C, respectively. The articles were analyzed using Readability Studio Professional Edition (Oleander Solutions, Vandalia, OH) using 10 different readability scales. The results were compared and averaged to identify the anticipated academic grade level required to understand the information. The average readability scores of the 10 scales had ranges of 9.7-16.4 for hepatitis B and 9.2-16.4 for hepatitis C. The average academic reading grade level for hepatitis B was 12.6 ± 2.1 and for hepatitis C was 12.7 ± 2.1. There was no significant discrepancy between the hepatitis B and C Internet resource averaged grade levels. The resources accessed by patients are higher than the previously determined necessary grade level for patients to properly understand the intended information. The American Medical Association recommends material should be simplified to grade levels below the sixth grade level to benefit the ideal proportion of the patient population.

  3. Calisthenics with words: The effect of readability and investor sophistication on investors' performance judgment

    OpenAIRE

    Cui, Xiao Carol

    2016-01-01

    Since the 1990s, the SEC has advocated for financial disclosures to be in “plain English” so that they would be more readable and informative. Past research has shown that high readability is related to more extreme investor judgments of firm performance. Processing fluency is the prevalent theory to explain this: higher readability increases the investor’s subconscious reliance on the disclosure, so positive (negative) news leads to more positive (negative) judgments. The relationship may no...

  4. Readability of Healthcare Literature for Gastroparesis and Evaluation of Medical Terminology in Reading Difficulty.

    Science.gov (United States)

    Meillier, Andrew; Patel, Shyam

    2017-02-01

    Gastroparesis is a chronic condition that can be further enhanced with patient understanding. Patients' education resources on the Internet have become increasingly important in improving healthcare literacy. We evaluated the readability of online resources for gastroparesis and the influence by medical terminology. Google searches were performed for "gastroparesis", "gastroparesis patient education material" and "gastroparesis patient information". Following, all medical terminology was determined if included on Taber's Medical Dictionary 22nd Edition. The medical terminology was replaced independently with "help" and "helping". Web resources were analyzed with the Readability Studio Professional Edition (Oleander Solutions, Vandalia, OH) using 10 different readability scales. The average of the 26 patient education resources was 12.7 ± 1.8 grade levels. The edited "help" group had 6.6 ± 1.0 and "helping" group had 10.4 ± 2.1 reading levels. In comparing the three groups, the "help" and "helping" groups had significantly lower readability levels (P Medical Association. Medical terminology was shown to be the cause for this elevated readability level with all, but four resources within the recommended grade levels following word replacement.

  5. Computer-readable ''Nuclear Data Sheets''

    International Nuclear Information System (INIS)

    Ewbank, W.B.

    1975-01-01

    The evaluated nuclear structure data contained in ''Nuclear Data Sheets'' are available in computer-readable form. Experimentally established properties of nuclear levels are included as well as radiations from nuclear reactions and radioactive decay. Portions of the data can be selected for distribution in several formats on magnetic tape or computer cards. A variety of different listing and drawing formats are also available. 4 figures

  6. SLSF loop handling system. Volume I. Structural analysis

    International Nuclear Information System (INIS)

    Ahmed, H.; Cowie, A.; Ma, D.

    1978-10-01

    SLSF loop handling system was analyzed for deadweight and postulated dynamic loading conditions, identified in Chapters II and III in Volume I of this report, using a linear elastic static equivalent method of stress analysis. Stress analysis of the loop handling machine is presented in Volume I of this report. Chapter VII in Volume I of this report is a contribution by EG and G Co., who performed the work under ANL supervision

  7. Cellular Manufacturing System with Dynamic Lot Size Material Handling

    Science.gov (United States)

    Khannan, M. S. A.; Maruf, A.; Wangsaputra, R.; Sutrisno, S.; Wibawa, T.

    2016-02-01

    Material Handling take as important role in Cellular Manufacturing System (CMS) design. In several study at CMS design material handling was assumed per pieces or with constant lot size. In real industrial practice, lot size may change during rolling period to cope with demand changes. This study develops CMS Model with Dynamic Lot Size Material Handling. Integer Linear Programming is used to solve the problem. Objective function of this model is minimizing total expected cost consisting machinery depreciation cost, operating costs, inter-cell material handling cost, intra-cell material handling cost, machine relocation costs, setup costs, and production planning cost. This model determines optimum cell formation and optimum lot size. Numerical examples are elaborated in the paper to ilustrate the characterictic of the model.

  8. How Readable Is BPH Treatment Information on the Internet? Assessing Barriers to Literacy in Prostate Health.

    Science.gov (United States)

    Koo, Kevin; Yap, Ronald L

    2017-03-01

    Information about benign prostatic hyperplasia (BPH) has become increasingly accessible on the Internet. Though the ability to find such material is encouraging, its readability and impact on informing patient decision making are not known. To evaluate the readability of Internet-based information about BPH in the context of website ownership and Health on the Net certification, three search engines were queried daily for 1 month with BPH-related keywords. Website ownership data and Health on the Net certification status were verified. Three readability analyses were performed: SMOG test, Dale-Chall readability formula, and Fry readability graph. An adjusted SMOG calculation was performed to reduce overestimation from medical jargon. After a total of 270 searches, 52 websites met inclusion criteria. Mean SMOG grade was 10.6 ( SD = 1.4) and 10.2 after adjustment. Mean Dale-Chall score was 9.1 ( SD = 0.6), or Grades 13 to 15. Mean Fry graph coordinates (173 syllables, 5.1 sentences) corresponded to Grade 15. Seven sites (13%) were at or below the average adult reading level based on SMOG; none of the sites qualified based on the other tests. Readability was significantly poorer for academic versus commercial sites and for Health on the Net-certified versus noncertified sites. In conclusion, online information about BPH treatment markedly exceeds the reading comprehension of most U.S. adults. Websites maintained by academic institutions and certified by the Health on the Net standard have more difficult readability. Efforts to improve literacy with respect to urological health should target content readability independent of reliability.

  9. Readability assessment of internet-based patient education materials related to facial fractures.

    Science.gov (United States)

    Sanghvi, Saurin; Cherla, Deepa V; Shukla, Pratik A; Eloy, Jean Anderson

    2012-09-01

    Various professional societies, clinical practices, hospitals, and health care-related Web sites provide Internet-based patient education material (IPEMs) to the general public. However, this information may be written above the 6th-grade reading level recommended by the US Department of Health and Human Services. The purpose of this study is to assess the readability of facial fracture (FF)-related IPEMs and compare readability levels of IPEMs provided by four sources: professional societies, clinical practices, hospitals, and miscellaneous sources. Analysis of IPEMs on FFs available on Google.com. The readability of 41 FF-related IPEMs was assessed with four readability indices: Flesch-Kincaid Grade Level (FKGL), Flesch Reading Ease Score (FRES), Simple Measure of Gobbledygook (SMOG), and Gunning Frequency of Gobbledygook (Gunning FOG). Averages were evaluated against national recommendations and between each source using analysis of variance and t tests. Only 4.9% of IPEMs were written at or below the 6th-grade reading level, based on FKGL. The mean readability scores were: FRES 54.10, FKGL 9.89, SMOG 12.73, and Gunning FOG 12.98, translating into FF-related IPEMs being written at a "difficult" writing level, which is above the level of reading understanding of the average American adult. IPEMs related to FFs are written above the recommended 6th-grade reading level. Consequently, this information would be difficult to understand by the average US patient. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  10. Readability of internet-sourced patient education material related to "labour analgesia".

    Science.gov (United States)

    Boztas, Nilay; Omur, Dilek; Ozbılgın, Sule; Altuntas, Gözde; Piskin, Ersan; Ozkardesler, Sevda; Hanci, Volkan

    2017-11-01

    We evaluated the readability of Internet-sourced patient education materials (PEMs) related to "labour analgesia." In addition to assessing the readability of websites, we aimed to compare commercial, personal, and academic websites.We used the most popular search engine (http://www.google.com) in our study. The first 100 websites in English that resulted from a search for the key words "labour analgesia" were scanned. Websites that were not in English, graphs, pictures, videos, tables, figures and list formats in the text, all punctuation, the number of words in the text is less than 100 words, feedback forms not related to education, (Uniform Resource Locator) URL websites, author information, references, legal disclaimers, and addresses and telephone numbers were excluded.The texts included in the study were assessed using the Flesch Reading Ease Score (FRES), Flesch-Kincaid Grade Level (FKGL), Simple Measure of Gobbledygook (SMOG), and Gunning Frequency of Gobbledygook (FOG) readability formulae. The number of Latin words within the text was determined.Analysis of 300-word sections of the texts revealed that the mean FRES was 47.54 ± 12.54 (quite difficult), mean FKGL and SMOG were 11.92 ± 2.59 and 10.57 ± 1.88 years of education, respectively, and mean Gunning FOG was 14.71 ± 2.76 (very difficult). Within 300-word sections, the mean number of Latin words was identified as 16.56 ± 6.37.In our study, the readability level of Internet-sourced PEM related to "labour analgesia" was identified to be quite high indicating poor readability.

  11. The Effect of Technology-Based Altered Readability Levels on Struggling Readers' Science Comprehension

    Science.gov (United States)

    Marino, Matthew T.; Coyne, Michael; Dunn, Michael

    2010-01-01

    This article reports findings from a study examining how altered readability levels affected struggling readers' (N = 288) comprehension of scientific concepts and vocabulary. Specifically, the researchers were interested in learning what effect altered readability levels have when low ability readers participate in a technology-based science…

  12. Quality and readability of online information resources on insomnia

    Institute of Scientific and Technical Information of China (English)

    Yan Ma; Albert C.Yang; Ying Duan; Ming Dong; Albert S.Yeung

    2017-01-01

    The internet is a major source for health information.An increasing number of people,including patients with insomnia,search for remedies online;however,little is known about the quality of such information.This study aimed to evaluate the quality and readability of insomnia-related online information.Google was used as the search engine,and the top websites on insomnia that met the inclusion criteria were evaluated for quality and readability.The analyzed websites belonged to nonprofit,commercial,or academic organizations and institutions such as hospitais and universities.Insomnia-related websites typically included definitions (85%),causes and risk factors (100%),symptoms (95%),and treatment options (90%).Cognitive behavioral therapy for insomnia (CBT-Ⅰ) was the most commonly recommended approach for insomnia treatment,and sleep drugs are frequently mentioned.The overall quality of the websites on insomnia is moderate,but all the content exceeded the recommended reading ease levels.Concerns that must be addressed to increase the quality and trustworthiness of online health information include sharing metadata,such as authorship,time of creation and last update,and conflicts of interest;providing evidence for reliability;and increasing the readability for a layman audience.

  13. [Readability and internet accessibility of informative documents for spinal cord injury patients in Spanish].

    Science.gov (United States)

    Bea-Muñoz, M; Medina-Sánchez, M; Flórez-García, M T

    2015-01-01

    Patients with spinal cord injuries and their carers have access to leaflets on Internet that they can use as educational material to complement traditional forms of education. The aim of this study is to evaluate the readability of informative documents in Spanish, obtained from Internet and aimed at patients with spinal cord injuries. A search was made with the Google search engine using the following key words: recommendation, advice, guide, manual, self-care, education and information, adding spinal cord injury, paraplegia and tetraplegia to each of the terms. We analyzed the first 50 results of each search. The readability of the leaflets was studied with the Flesch-Szigriszt index and the INFLESZ scale, both available on the INFLESZ program. Also indicated were year of publication, country and number of authors of the documents obtained. We obtained 16 documents, developed between 2001 and 2011. Readability oscillated between 43.34 (some-what difficult) and 62 (normal), with an average value of 51.56 (somewhat difficult). Only 4 pamphlets (25%) showed a Flesch-Szigriszt index of ≥ 55 (normal). There was no difference in readability by year, authors or country of publication. The readability of 75% of the documents studied was "somewhat difficult" according to the INFLESZ scale. These results coincide with previous studies, in both Spanish and English. If the readability of this type of documents is improved, it will be easier to achieve their educational goal.

  14. Calisthenics with Words: The Effect of Readability and Investor Sophistication on Investors’ Performance Judgment

    Directory of Open Access Journals (Sweden)

    Xiao Carol Cui

    2016-01-01

    Full Text Available Since the 1990s, the SEC has advocated for financial disclosures to be in “plain English” so that they would be more readable and informative. Past research has shown that high readability is related to more extreme investor judgments of firm performance. Processing fluency is the prevalent theory to explain this: higher readability increases the investor’s subconscious reliance on the disclosure, so positive (negative news leads to more positive (negative judgments. The relationship may not be so simple, though: drawing on research from cognitive psychology, I predict and find that investor financial literacy simultaneously influences investor decision-making, and that it has an interactive effect with readability. When presented with financial disclosure containing conflicting financial information, investors with higher financial literacy make more negative judgments than investors with low financial literacy when the disclosure is easy to read, but the effect becomes insignificant when the disclosure becomes difficult to read. This effect is moderated by a comprehension gap between the two investor groups. Financial literacy and readability interact to impact both how and how well the investor processes financial information.

  15. Readability Levels of Dental Patient Education Brochures.

    Science.gov (United States)

    Boles, Catherine D; Liu, Ying; November-Rider, Debra

    2016-02-01

    The objective of this study was to evaluate dental patient education brochures produced since 2000 to determine if there is any change in the Flesch-Kincaid grade level readability. A convenience sample of 36 brochures was obtained for analysis of the readability of the patient education material on multiple dental topics. Readability was measured using the Flesch-Kincaid Grade Level through Microsoft Word. Pearson's correlation was used to describe the relationship among the factors of interest. Backward model selection of multiple linear regression model was used to investigate the relationship between Flesch-Kincaid Grade level and a set of predictors included in this study. A convenience sample (n=36) of dental education brochures produced from 2000 to 2014 showed a mean Flesch-Kincaid reading grade level of 9.15. Weak to moderate correlations existed between word count and grade level (r=0.40) and characters count and grade level (r=0.46); strong correlations were found between grade level and average words per sentence (r=0.70), average characters per word (r=0.85) and Flesch Reading Ease (r=-0.98). Only 1 brochure out of the sample met the recommended sixth grade reading level (Flesch-Kincaid Grade Level 5.7). Overall, the Flesch-Kincaid Grade Level of all brochures was significantly higher than the recommended sixth grade reading level (preadability of the brochures. However, the majority of the brochures analyzed are still testing above the recommended sixth grade reading level. Copyright © 2016 The American Dental Hygienists’ Association.

  16. Computational Text Analysis: A More Comprehensive Approach to Determine Readability of Reading Materials

    Science.gov (United States)

    Aziz, Anealka; Fook, Chan Yuen; Alsree, Zubaida

    2010-01-01

    Reading materials are considered having high readability if readers are interested to read the materials, understand the content of the materials and able to read the materials fluently. In contrast, reading materials with low readability discourage readers from reading the materials, create difficulties for readers to understand the content of…

  17. Readability of Early Intervention Program Literature

    Science.gov (United States)

    Pizur-Barnekow, Kris; Patrick, Timothy; Rhyner, Paula M.; Cashin, Susan; Rentmeester, Angela

    2011-01-01

    Accessibility of early intervention program literature was examined through readability analysis of documents given to families who have a child served by the Birth to 3 program. Nine agencies that serve families in Birth to 3 programs located in a county in the Midwest provided the (n = 94) documents. Documents were included in the analysis if…

  18. Remote Inspection, Measurement and Handling for LHC

    CERN Document Server

    Kershaw, K; Coin, A; Delsaux, F; Feniet, T; Grenard, J L; Valbuena, R

    2007-01-01

    Personnel access to the LHC tunnel will be restricted to varying extents during the life of the machine due to radiation, cryogenic and pressure hazards. The ability to carry out visual inspection, measurement and handling activities remotely during periods when the LHC tunnel is potentially hazardous offers advantages in terms of safety, accelerator down time, and costs. The first applications identified were remote measurement of radiation levels at the start of shut-down, remote geometrical survey measurements in the collimation regions, and remote visual inspection during pressure testing and initial machine cool-down. In addition, for remote handling operations, it will be necessary to be able to transmit several real-time video images from the tunnel to the control room. The paper describes the design, development and use of a remotely controlled vehicle to demonstrate the feasibility of meeting the above requirements in the LHC tunnel. Design choices are explained along with operating experience to-dat...

  19. Readability of American online patient education materials in urologic oncology: a need for simple communication.

    Science.gov (United States)

    Pruthi, Amanda; Nielsen, Matthew E; Raynor, Mathew C; Woods, Michael E; Wallen, Eric M; Smith, Angela B

    2015-02-01

    To determine the readability levels of reputable cancer and urologic Web sites addressing bladder, prostate, kidney, and testicular cancers. Online patient education materials (PEMs) for bladder, prostate, kidney, and testicular malignancies were evaluated from the American Cancer Society, American Society of Clinical Oncology, National Cancer Institute, Urology Care Foundation, Bladder Cancer Advocacy Network, Prostate Cancer Foundation, Kidney Cancer Association, and Testicular Cancer Resource Center. Grade level was determined using several readability indices, and analyses were performed on the basis of cancer type, Web site, and content area (general, causes, risk factors and prevention, diagnosis and staging, treatment, and post-treatment). Estimated grade level of online PEMs ranged from 9.2 to 14.2 with an overall mean of 11.7. Web sites for kidney cancer had the least difficult readability (11.3) and prostate cancer had the most difficult readability (12.1). Among specific Web sites, the most difficult readability levels were noted for the Urology Care Foundation Web site for bladder and prostate cancer and the Kidney Cancer Association and Testicular Cancer Resource Center for kidney and testes cancer. Readability levels within content areas varied on the basis of the disease and Web site. Online PEMs in urologic oncology are written at a level above the average American reader. Simplification of these resources is necessary to improve patient understanding of urologic malignancy. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Readability of informed consent forms in vascular and interventional radiology

    International Nuclear Information System (INIS)

    Pinto, I.; Vigil, D.

    1998-01-01

    To evaluate the readability of the informed consent forms prepared for vascular and interventional radiology. The 18 informed consent forms were analyzed using the Gramatica tool employed in Microsoft Word 97 For Windows which combines the statistics on legibility in terms of three sections: scores, averages and legibility (Flech index, passive voice, sentence complexity and vocabulary complexity). For each, the integrated readability index was also manually calculated. All the documents present a Flesch index of over 10; the sentence complexity indexes are less than or equal to 20, demonstrating that the sentences are not long or complicated in structure. Finally, the integrated readability index of all of them is well over 70. The forms posses acceptable legibility indexes, but their evaluation should be completed by an opinion poll of the patients for whom they are written. Moreover, it must be kept in mind that these documents, like the procedures performed, are changing continually. Thus, it is necessary to update and modify the information to be provided to the patients. (Author) 11 refs

  1. Machine learning for adaptive many-core machines a practical approach

    CERN Document Server

    Lopes, Noel

    2015-01-01

    The overwhelming data produced everyday and the increasing performance and cost requirements of applications?are transversal to a wide range of activities in society, from science to industry. In particular, the magnitude and complexity of the tasks that Machine Learning (ML) algorithms have to solve are driving the need to devise adaptive many-core machines that scale well with the volume of data, or in other words, can handle Big Data.This book gives a concise view on how to extend the applicability of well-known ML algorithms in Graphics Processing Unit (GPU) with data scalability in mind.

  2. Method of generating a computer readable model

    DEFF Research Database (Denmark)

    2008-01-01

    A method of generating a computer readable model of a geometrical object constructed from a plurality of interconnectable construction elements, wherein each construction element has a number of connection elements for connecting the construction element with another construction element. The met......A method of generating a computer readable model of a geometrical object constructed from a plurality of interconnectable construction elements, wherein each construction element has a number of connection elements for connecting the construction element with another construction element....... The method comprises encoding a first and a second one of the construction elements as corresponding data structures, each representing the connection elements of the corresponding construction element, and each of the connection elements having associated with it a predetermined connection type. The method...... further comprises determining a first connection element of the first construction element and a second connection element of the second construction element located in a predetermined proximity of each other; and retrieving connectivity information of the corresponding connection types of the first...

  3. Observations on human-technology interaction aspects in remote handling for fusion

    International Nuclear Information System (INIS)

    Salminen, Karoliina

    2009-01-01

    Remote handling can been seen as cooperation between human and machine. One of the characteristics of remote handling is that there is always a human involved in the technique: there is always a human guiding and supervising the movements and deciding the actions of the machine. Unlike many other fields of remote handling for fusion, the human-technology interaction side has not been studied carefully recently. The state-of-the-art research about different kinds of remote handling systems shows that there is a lot of information available in this subject, but there is a clear need for studies where the special needs of ITER are taken into account. During the PREFIT programme, the human-interaction aspects of remote handling have been studied, and the goal has been to find solutions compatible with ITER. Some of the aspects that make ITER a unique system are its new technology combining state-of-the-art knowledge from several different fields, and its very international working environment. When discussing the human aspects, the fact of the multinational cooperation cannot be neglected. Since the majority of the information found in the literature review is not about remote handling, references need to be taken from other industries, like aviation. This article consists of ITER remote handling relevant findings in state-of-the-art research and information and knowledge gained during the PREFIT programme, especially during the training periods at JET in Culham and at CEA in Fontenay-aux-Roses. It also discusses the importance of human-technology interaction field in remote handling, especially in ITER.

  4. The quality and readability of internet information regarding clavicle fractures.

    Science.gov (United States)

    Zhang, Dafang; Schumacher, Charles; Harris, Mitchel Byron

    2016-03-01

    The internet has become a major source of health information for patients. However, there has been little scrutiny of health information available on the internet to the public. Our objectives were to evaluate the quality and readability of information available on the internet regarding clavicle fractures and whether they changed with academic affiliation of the website or with complexity of the search term. Through a prospective evaluation of 3 search engines using 3 different search terms of varying complexity ("broken collarbone," "collarbone fracture," and "clavicle fracture"), we evaluated 91 website hits for quality and readability. Websites were specifically analyzed by search term and by website type. Information quality was evaluated on a four-point scale, and information readability was assessed using the Flesch-Kincaid score for reading grade level. The average quality score for our website hits was low, and the average reading grade level was far above the recommended level. Academic websites offered significantly higher quality information, whereas commercial websites offered significantly lower quality information. The use of more complex search terms yielded information of higher reading grade level but not higher quality. Current internet information regarding clavicle fractures is of low quality and low readability. Higher quality information utilizing more accessible language on clavicle fractures is needed on the internet. It is important to be aware of the information accessible to patients prior to their presentation to our clinics. Patients should be advised to visit websites with academic affiliations and to avoid commercial websites. Copyright © 2015 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  5. [Global analysis of the readability of the informed consent forms used in public hospitals of Spain].

    Science.gov (United States)

    Mariscal-Crespo, M I; Coronado-Vázquez, M V; Ramirez-Durán, M V

    To analyse the readability of informed consent forms (ICF) used in Public Hospitals throughout Spain, with the aim of checking their function of providing comprehensive information to people who are making any health decision no matter where they are in Spain. A descriptive study was performed on a total of 11,339 ICF received from all over Spanish territory, of which 1617 ICF were collected from 4 web pages of Health Portal and the rest (9722) were received through email and/or telephone contact from March 2012 to February 2013. The readability level was studied using the Inflesz tool. A total of 372 ICF were selected and analysed using simple random sampling. The Inflesz scale and the Flesch-Szigriszt index were used to analyse the readability. The readability results showed that 62.4% of the ICF were rated as a "little difficult", the 23.4% as "normal", and the 13.4% were rated as "very difficult". The highest readability means using the Flesch index were scored in Andalusia with a mean of 56.99 (95% CI; 55.42-58.57) and Valencia with a mean of 51.93 (95% CI; 48.4-55.52). The lowest readability means were in Galicia with a mean of 40.77 (95% CI; 9.83-71.71) and Melilla, mean=41.82 (95% CI; 35.5-48.14). The readability level of Spanish informed consent forms must be improved because their scores using readability tools could not be classified in normal scales. Furthermore, there was very wide variability among Spanish ICF, which showed a lack of equity in information access among Spanish citizens. Copyright © 2017 SECA. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Readability assessment of online patient education materials provided by the European Association of Urology.

    Science.gov (United States)

    Betschart, Patrick; Zumstein, Valentin; Bentivoglio, Maico; Engeler, Daniel; Schmid, Hans-Peter; Abt, Dominik

    2017-12-01

    To assess the readability of the web-based patient education material provided by the European Association of Urology. English patient education materials (PEM) as available in May 2017 were obtained from the EAU website. Each topic was analyzed separately using six well-established readability assessment tools, including Flesch-Kincaid Grade Level (FKGL), SMOG Grade Level (SMOG), Coleman-Liau Index (CLI), Gunning Fog Index (GFI), Flesch Reading Ease Formula (FRE) and Fry Readability Graph (FRG). A total of 17 main topics were identified of which separate basic and in-depth information is provided for 14 topics. Calculation of grade levels (FKGL, SMOG, CLI, GFI) showed readability scores of 7th-13th grade for basic information, 8th-15th grade for in-depth information and 7th-15th grade for single PEM. Median FRE score was 54 points (range 45-65) for basic information and 56 points (41-64) for in-depth information. The FRG as a graphical assessment revealed only 13 valid results with an approximate 8th-17th grade level. The EAU provides carefully worked out PEM for 17 urological topics. Although improved readability compared to similar analyses was found, a simplification of certain chapters might be helpful to facilitate better patient understanding.

  7. Development of first full scope commercial CANDU-6 fuel handling simulator

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, W., E-mail: BCrawford@atlanticnuclear.ca [Atlantic Nuclear Services Inc., Fredericton, NB (Canada); McInerney, J. M., E-mail: JMcInerney@nbpower.com [Point Lepreau Generating Station, Maces Bay, NB (Canada); Moran, E.S.; Nice, J. W.; Sinclair, D.M.; Somerville, S.; Usalp, E.C.; Usalp, M., E-mail: EMoran@atlanticnuclear.ca, E-mail: JNice@atlanticnuclear.ca, E-mail: DSinclair@atlanticnuclear.ca, E-mail: SSomerville@atlanticnuclear.ca, E-mail: ECUsalp@atlanticnuclear.ca, E-mail: MUsalp@atlanticnuclear.ca [Atlantic Nuclear Services Inc., Fredericton, NB (Canada)

    2015-07-01

    Unique to CANDU reactors is continuous on-power refueling. In the CANDU-6 design, the fuel bundles are contained within 380 pressure tubes. Fuelling machines, one on either side of the reactor face move on a bridge and carriage system to the appointed channel and fuel under computer control. The fuelling machine is an immensely complicated mechanical device. None of the original Canadian full scope simulators incorporated the interaction of the fuel handling system. Traditionally, the final stages of Fuel Handling Operator qualification utilizes on the job training in a production environment carried out in the station main control room. For the purpose of supporting continual improvement in fuel handling training at the Third Qinshan Nuclear Plant Company (TQNPC), Atlantic Nuclear Services in a joint project with New Brunswick Power, developed the first commercial full scope CANDU-6 Fuel Handling simulator, integrated into the existing TQNPC Full Scope Simulator framework. The TQNPC Fuel Handling simulator is capable of supporting all normal on-power and off-power refuelling procedures as well as other abnormal operating conditions, which will allow training to be conducted, based on the plant specific operating procedures. This paper will discuss its development, the importance of this tool and its advantages over past training practices. (author)

  8. Development of first full scope commercial CANDU-6 fuel handling simulator

    International Nuclear Information System (INIS)

    Crawford, W.; McInerney, J. M.; Moran, E.S.; Nice, J. W.; Sinclair, D.M.; Somerville, S.; Usalp, E.C.; Usalp, M.

    2015-01-01

    Unique to CANDU reactors is continuous on-power refueling. In the CANDU-6 design, the fuel bundles are contained within 380 pressure tubes. Fuelling machines, one on either side of the reactor face move on a bridge and carriage system to the appointed channel and fuel under computer control. The fuelling machine is an immensely complicated mechanical device. None of the original Canadian full scope simulators incorporated the interaction of the fuel handling system. Traditionally, the final stages of Fuel Handling Operator qualification utilizes on the job training in a production environment carried out in the station main control room. For the purpose of supporting continual improvement in fuel handling training at the Third Qinshan Nuclear Plant Company (TQNPC), Atlantic Nuclear Services in a joint project with New Brunswick Power, developed the first commercial full scope CANDU-6 Fuel Handling simulator, integrated into the existing TQNPC Full Scope Simulator framework. The TQNPC Fuel Handling simulator is capable of supporting all normal on-power and off-power refuelling procedures as well as other abnormal operating conditions, which will allow training to be conducted, based on the plant specific operating procedures. This paper will discuss its development, the importance of this tool and its advantages over past training practices. (author)

  9. Readability assessment of Internet-based patient education materials related to endoscopic sinus surgery.

    Science.gov (United States)

    Cherla, Deepa V; Sanghvi, Saurin; Choudhry, Osamah J; Liu, James K; Eloy, Jean Anderson

    2012-08-01

    Numerous professional societies, clinical practices, and hospitals provide Internet-based patient education materials (PEMs) to the general public, but not all of this information is written at a reading level appropriate for the average patient. The National Institutes of Health and the US Department of Health and Human Services recommend that PEMs be written at or below the sixth-grade level. Our purpose was to assess the readability of endoscopic sinus surgery (ESS)-related PEMs available on the Internet and compare readability levels of PEMs provided by three sources: professional societies, clinical practices, and hospitals. A descriptive and correlational design was used for this study. The readability of 31 ESS-related PEMs was assessed with four different readability indices: Flesch-Kincaid Grade Level (FKGL), Flesch Reading Ease Score (FRES), Simple Measure of Gobbledygook (SMOG), and Gunning Frequency of Gobbledygook (Gunning FOG). Averages were evaluated against national recommendations and between each source using analysis of variance and t tests. The majority of PEMs (96.8%) were written above the recommended sixth-grade reading level, based on FKGL (P Internet-based PEMs related to ESS, regardless of source type, were written well above the recommended sixth-grade level. Materials from the hospitals/university-affiliated websites had lower readability scores, but were still above recommended levels. Web-based PEMs pertaining to ESS should be written with the average patient in mind. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  10. Readability of Patient Education Materials From the Web Sites of Orthopedic Implant Manufacturers.

    Science.gov (United States)

    Yi, Meghan M; Yi, Paul H; Hussein, Khalil I; Cross, Michael B; Della Valle, Craig J

    2017-12-01

    Prior studies indicate that orthopedic patient education materials are written at a level that is too high for the average patient. The purpose of this study was to assess the readability of online patient education materials provided by orthopedic implant manufacturers. All patient education articles available in 2013 from the web sites of the 5 largest orthopedic implant manufacturers were identified. Each article was evaluated with the Flesch-Kincaid (FK) readability test. The number of articles with readability ≤ the eighth-grade level (average reading ability of US adults) and the sixth-grade level (recommended level for patient education materials) was determined. Mean readability levels of each company's articles were compared using analysis of variance (significance set at P articles were reviewed from the 5 largest implant manufacturers. The mean overall FK grade level was 10.9 (range, 3.8-16.1). Only 58 articles (10%) were written ≤ the eighth-grade level, and only 13 (2.2%) were ≤ the sixth-grade level. The mean FK grade level was significantly different among groups (Smith & Nephew = 12.0, Stryker = 11.6, Biomet = 11.3, DePuy = 10.6, Zimmer = 10.1; P education materials from implant manufacturers are written at a level too high to be comprehended by the average patient. Future efforts should be made to improve the readability of orthopedic patient education materials. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Hoisting appliances and fuel handling equipment at nuclear facilities

    International Nuclear Information System (INIS)

    1987-01-01

    The guide is followed by the Finnish Centre for Radiation and Nuclear Safety (STUK) in regulating hoisting and handling equipment Class 3 at nuclear facilities. The guide is applied e.g. to the following equipment: reactor building overhead cranes, hoisting appliances at nuclear fuel storages, fuel handling machines, other hoisting appliances, which because of nuclear safety aspects are classified in Safety Class 3, and load-bearing devices connected with the above equipment, such as replaceable hoisting tools and auxiliary lifting devices. The regulating of hoisting and handling equipment comprises the following stages: handling of preliminary and final safety analysis reports, inspection of the construction plan, supervision of fabrication and construction inspection, and supervision of initial start-up and commissioning inspection

  12. Readability of internet-sourced patient education material related to “labour analgesia”

    Science.gov (United States)

    Boztas, Nilay; Omur, Dilek; Ozbılgın, Sule; Altuntas, Gözde; Piskin, Ersan; Ozkardesler, Sevda; Hanci, Volkan

    2017-01-01

    Abstract We evaluated the readability of Internet-sourced patient education materials (PEMs) related to “labour analgesia.” In addition to assessing the readability of websites, we aimed to compare commercial, personal, and academic websites. We used the most popular search engine (http://www.google.com) in our study. The first 100 websites in English that resulted from a search for the key words “labour analgesia” were scanned. Websites that were not in English, graphs, pictures, videos, tables, figures and list formats in the text, all punctuation, the number of words in the text is less than 100 words, feedback forms not related to education, (Uniform Resource Locator) URL websites, author information, references, legal disclaimers, and addresses and telephone numbers were excluded. The texts included in the study were assessed using the Flesch Reading Ease Score (FRES), Flesch-Kincaid Grade Level (FKGL), Simple Measure of Gobbledygook (SMOG), and Gunning Frequency of Gobbledygook (FOG) readability formulae. The number of Latin words within the text was determined. Analysis of 300-word sections of the texts revealed that the mean FRES was 47.54 ± 12.54 (quite difficult), mean FKGL and SMOG were 11.92 ± 2.59 and 10.57 ± 1.88 years of education, respectively, and mean Gunning FOG was 14.71 ± 2.76 (very difficult). Within 300-word sections, the mean number of Latin words was identified as 16.56 ± 6.37. In our study, the readability level of Internet-sourced PEM related to “labour analgesia” was identified to be quite high indicating poor readability. PMID:29137057

  13. Readability Formulas as Applied to College Economics Textbooks.

    Science.gov (United States)

    McConnell, Campbell R.

    1982-01-01

    Determines from empirical information on the application of four readability formulas to a group of widely used college economics textbooks that there is no consistency in the absolute reading levels or the rank orderings of these books. (AEA)

  14. Readability of Malaria Medicine Information Leaflets in Nigeria

    African Journals Online (AJOL)

    Erah

    2010-12-18

    Dec 18, 2010 ... for malaria medicines information leaflets available in Nigeria was 13.69 ± 1.70. This value is equivalent ... Health promotion and behaviour change communication ... their rational use at the community level. Readability is the ...

  15. Analysis of Readability and Interest of Marketing Education Textbooks: Implications for Special Needs Learners.

    Science.gov (United States)

    Jones, Karen H.; And Others

    1993-01-01

    The readability, reading ease, interest level, and writing style of 20 current textbooks in secondary marketing education were evaluated. Readability formulas consistently identified lower reading levels for special needs education, human interest scores were not very reliable information sources, and writing style was also a weak variable. (JOW)

  16. A Readability Analysis of Selected Introductory Economics.

    Science.gov (United States)

    Gallagher, Daniel J.; Thompson, G. Rodney

    1981-01-01

    To aid secondary school and college level economics teachers as they select textbooks for introductory economics courses, this article recounts how teachers can use the Flesch Reading Ease Test to measure readability. Data are presented on application of the Flesch Reading Ease Test to 15 introductory economics textbooks. (Author/DB)

  17. Online Patient Resources for Liposuction: A Comparative Analysis of Readability.

    Science.gov (United States)

    Vargas, Christina R; Ricci, Joseph A; Chuang, Danielle J; Lee, Bernard T

    2016-03-01

    As patients strive to become informed about health care, inadequate functional health literacy is a significant barrier. Nearly half of American adults have poor or marginal health literacy skills and the National Institutes of Health and American Medical Association have recommended that patient information should be written at a sixth grade level. The aim of this study is to identify the most commonly used online patient information about liposuction and to evaluate its readability relative to average American literacy. An internet search of "liposuction" was performed and the 10 most popular websites identified. User and location data were disabled and sponsored results excluded. All relevant, patient-directed articles were downloaded and formatted into plain text. Articles were then analyzed using 10 established readability tests. A comparison group was constructed to identify the most popular online consumer information about tattooing. Mean readability scores and specific article characteristics were compared. A total of 80 articles were collected from websites about liposuction. Readability analysis revealed an overall 13.6 grade reading level (range, 10-16 grade); all articles exceeded the target sixth grade level. Consumer websites about tattooing were significantly easier to read, with a mean 7.8 grade level. These sites contained significantly fewer characters per word and words per sentence, as well as a smaller proportion of complex, long, and unfamiliar words. Online patient resources about liposuction are potentially too difficult for a large number of Americans to understand. Liposuction websites are significantly harder to read than consumer websites about tattooing. Aesthetic surgeons are advised to discuss with patients resources they use and guide patients to appropriate information for their skill level.

  18. Measuring the Readability of Children's Trade Books.

    Science.gov (United States)

    Popp, Helen M.; Porter, Douglas

    In order to utilize interesting children's trade books in a systematic reading program, two readability formulas were devised based on a selection of children's trade books. Children's scores on selections from these books and judges' rankings were compared. The judges' decisions were considered to be highly credible and were used as the criterion…

  19. Readability and Content Assessment of Informed Consent Forms for Phase II-IV Clinical Trials in China.

    Science.gov (United States)

    Wen, Gaiyan; Liu, Xinchun; Huang, Lihua; Shu, Jingxian; Xu, Nana; Chen, Ruifang; Huang, Zhijun; Yang, Guoping; Wang, Xiaomin; Xiang, Yuxia; Lu, Yao; Yuan, Hong

    2016-01-01

    To explore the readability and content integrity of informed consent forms (ICFs) used in China and to compare the quality of Chinese local ICFs with that of international ICFs. The length, readability and content of 155 consent documents from phase II-IV drug clinical trials from the Third Xiangya Hospital Ethics Committee from November 2009 to January 2015 were evaluated. Reading difficulty was tested using a readability formula adapted for the Chinese language. An ICF checklist containing 27 required elements was successfully constructed to evaluate content integrity. The description of alternatives to participation was assessed. The quality of ICFs from different sponsorships were also compared. Among the 155 evaluable trials, the ICFs had a median length of 5286 words, corresponding to 7 pages. The median readability score was 4.31 (4.02-4.41), with 63.9% at the 2nd level and 36.1% at the 3rd level. Five of the 27 elements were frequently neglected. The average score for the description of alternatives to participation was 1.06, and 27.7% of the ICFs did not mention any alternatives. Compared with Chinese local ICFs, international ICFs were longer, more readable and contained more of the required elements (P readability and content integrity than Chinese local ICFs. More efforts should thus be made to improve the quality of consent documents in China.

  20. Xeml Lab: a tool that supports the design of experiments at a graphical interface and generates computer-readable metadata files, which capture information about genotypes, growth conditions, environmental perturbations and sampling strategy.

    Science.gov (United States)

    Hannemann, Jan; Poorter, Hendrik; Usadel, Björn; Bläsing, Oliver E; Finck, Alex; Tardieu, Francois; Atkin, Owen K; Pons, Thijs; Stitt, Mark; Gibon, Yves

    2009-09-01

    Data mining depends on the ability to access machine-readable metadata that describe genotypes, environmental conditions, and sampling times and strategy. This article presents Xeml Lab. The Xeml Interactive Designer provides an interactive graphical interface at which complex experiments can be designed, and concomitantly generates machine-readable metadata files. It uses a new eXtensible Mark-up Language (XML)-derived dialect termed XEML. Xeml Lab includes a new ontology for environmental conditions, called Xeml Environment Ontology. However, to provide versatility, it is designed to be generic and also accepts other commonly used ontology formats, including OBO and OWL. A review summarizing important environmental conditions that need to be controlled, monitored and captured as metadata is posted in a Wiki (http://www.codeplex.com/XeO) to promote community discussion. The usefulness of Xeml Lab is illustrated by two meta-analyses of a large set of experiments that were performed with Arabidopsis thaliana during 5 years. The first reveals sources of noise that affect measurements of metabolite levels and enzyme activities. The second shows that Arabidopsis maintains remarkably stable levels of sugars and amino acids across a wide range of photoperiod treatments, and that adjustment of starch turnover and the leaf protein content contribute to this metabolic homeostasis.

  1. Development of remote handling tools for glove box

    International Nuclear Information System (INIS)

    Tomita, Yutaka; Nemoto, Takeshi; Denuma, Akio; Todokoro, Akio

    1996-01-01

    For a part of advanced nuclear fuel recycling technology development, we will separate and recover Americium from the MOX fuel scrap by solvent extraction. When we carry this examination, reduction of exposure from Americium-241 is one of important problems. To solve this problem fundamentally, we studied many joints type of the remote handling tools for glove box and produced a trial production machine. Also, we carried out basic function examinations of it. As a result, we got the prospect of development of the remote handling tools which could treat Americium in glove box. (author)

  2. Measuring the readability of sustainability reports: : A corpus-based analysis through standard formulae and NLP

    NARCIS (Netherlands)

    Smeuninx, N.; De Clerck, B.; Aerts, Walter

    2016-01-01

    This study characterises and problematises the language of corporate reporting along region, industry, genre, and content lines by applying readability formulae and more advanced natural language processing (NLP)–based analysis to a manually assembled 2.75-million-word corpus. Readability formulae

  3. Assessment of readability, quality and popularity of online information on ureteral stents.

    Science.gov (United States)

    Mozafarpour, Sarah; Norris, Briony; Borin, James; Eisner, Brian H

    2018-02-12

    To evaluate the quality and readability of online information on ureteral stents. Google.com was queried using the search terms "ureteric stent", "ureteral stent", "double J stent" and, "Kidney stent" derived from Google AdWords. Website popularity was determined using Google Rank and the Alexa tool. Website quality assessment was performed using the following criteria: Journal of the American Medical Association (JAMA) benchmarks, Health on the Net (HON) criteria, and a customized DISCERN questionnaire. The customized DISCERN questionnaire was developed by combining the short validated DISCERN questionnaire with additional stent-specific items including definition, placement, complications, limitations, removal and "when to seek help". Scores related to stent items were considered as the "stent score" (SS). Readability was evaluated using five readability tests. Thirty-two websites were included. The mean customized DISCERN score and "stent score" were 27.1 ± 7.1 (maximum possible score = 59) and 14.6 ± 3.8 (maximum possible score = 24), respectively. A minority of websites adequately addressed "stent removal" and "when to seek medical attention". Only two websites (6.3%) had HON certification (drugs.com, radiologyinfo.org) and only one website (3.3%) met all JAMA criteria (bradyurology.blogspot.com). Readability level was higher than the American Medical Association recommendation of sixth-grade level for more than 75% of the websites. There was no correlation between Google rank, Alexa rank, and the quality scores (P > 0.05). Among the 32 most popular websites on the topic of ureteral stents, online information was highly variable. The readability of many of the websites was far higher than standard recommendations and the online information was questionable in many cases. These findings suggest a need for improved online resources in order to better educate patients about ureteral stents and also should inform physicians that popular websites may

  4. Readability Formulas and User Perceptions of Electronic Health Records Difficulty: A Corpus Study.

    Science.gov (United States)

    Zheng, Jiaping; Yu, Hong

    2017-03-02

    Electronic health records (EHRs) are a rich resource for developing applications to engage patients and foster patient activation, thus holding a strong potential to enhance patient-centered care. Studies have shown that providing patients with access to their own EHR notes may improve the understanding of their own clinical conditions and treatments, leading to improved health care outcomes. However, the highly technical language in EHR notes impedes patients' comprehension. Numerous studies have evaluated the difficulty of health-related text using readability formulas such as Flesch-Kincaid Grade Level (FKGL), Simple Measure of Gobbledygook (SMOG), and Gunning-Fog Index (GFI). They conclude that the materials are often written at a grade level higher than common recommendations. The objective of our study was to explore the relationship between the aforementioned readability formulas and the laypeople's perceived difficulty on 2 genres of text: general health information and EHR notes. We also validated the formulas' appropriateness and generalizability on predicting difficulty levels of highly complex technical documents. We collected 140 Wikipedia articles on diabetes and 242 EHR notes with diabetes International Classification of Diseases, Ninth Revision code. We recruited 15 Amazon Mechanical Turk (AMT) users to rate difficulty levels of the documents. Correlations between laypeople's perceived difficulty levels and readability formula scores were measured, and their difference was tested. We also compared word usage and the impact of medical concepts of the 2 genres of text. The distributions of both readability formulas' scores (Preadability predictions and laypeople's perceptions were weak. Furthermore, despite being graded at similar levels, documents of different genres were still perceived with different difficulty (Preadability formulas' predictions did not align with perceived difficulty in either text genre. The widely used readability formulas were

  5. Readability of informed consent forms in clinical trials conducted in a skin research center

    Science.gov (United States)

    Samadi, Aniseh; Asghari, Fariba

    2016-01-01

    Obtaining informed consents is one of the most fundamental principles in conducting a clinical trial. In order for the consent to be informed, the patient must receive and comprehend the information appropriately. Complexity of the consent form is a common problem that has been shown to be a major barrier to comprehension for many patients. The objective of this study was to assess the readability of different templates of informed consent forms (ICFs) used in clinical trials in the Center for Research and Training in Skin Diseases and Leprosy (CRTSDL), Tehran, Iran. This study was conducted on ICFs of 45 clinical trials of the CRTSDL affiliated with Tehran University of Medical Sciences. ICFs were tested for reading difficulty, using the readability assessments formula adjusted for the Persian language including the Flesch–Kincaid reading ease score, Flesch–Kincaid grade level, and Gunning fog index. Mean readability score of the whole text of ICFs as well as their 7 main information parts were calculated. The mean ± SD Flesch Reading Ease score for all ICFs was 31.96 ± 5.62 that is in the difficult range. The mean ± SD grade level was calculated as 10.71 ± 1.8 (8.23–14.09) using the Flesch–Kincaid formula and 14.64 ± 1.22 (12.67–18.27) using the Gunning fog index. These results indicate that the text is expected to be understandable for an average student in the 11th grade, while the ethics committee recommend grade level 8 as the standard readability level for ICFs. The results showed that the readability scores of ICFs assessed in our study were not in the acceptable range. This means they were too complex to be understood by the general population. Ethics committees must examine the simplicity and readability of ICFs used in clinical trials. PMID:27471590

  6. Cauda equina syndrome: assessing the readability and quality of patient information on the Internet.

    Science.gov (United States)

    O'Neill, Shane Ciaran; Baker, Joseph Frederick; Fitzgerald, Conall; Fleming, Christina; Rowan, Fiachra; Byrne, Damien; Synnott, Keith

    2014-05-01

    A readability and quality control Internet-based study using recognized quality scoring systems. To assess the readability and quality of Internet information relating to cauda equina syndrome accessed through common search engines. Access to health-related Internet information has increased dramatically during the past decade. A significant proportion of this information has been demonstrated to be set at too high a level for general comprehension. Despite this, searching for health-related information is now the third most popular online activity. A total of 125 cauda equina syndrome Web sites were analyzed from the 5 most popular Internet search engines: Google, Bing, Yahoo, Ask, and AOL. Web site authorship was classified: academic, physician, medico-legal, commercial, or discussion/social media. Readability of each Web site was assessed using the Flesch Reading Ease score, the Flesch-Kincaid grade level, and the Gunning Fog Index. Quality was calculated using the DISCERN instrument and The Journal of the American Medical Association benchmark criteria. The presence of HON-code certification was also assessed. Fifty-two individual Web sites were identified and assessed. The majority of Web sites were academic or physician compiled (53.8%; 28/52); however, a significant minority of Web sites were medico-legal related (19.2%; 10/52). Just 13.5% (7/52) of Web sites were at or below the recommended sixth-grade readability level. HON-code certified Web sites achieved significantly greater DISCERN (P = 0.0006) and The Journal of the American Medical Association (P = 0.0002) scores. Internet information relating to cauda equina syndrome is of variable quality and largely set at an inappropriate readability level. Given this variability in quality, health care providers should direct patients to known sources of reliable, readable online information. Identification of reliable sources may be aided by known markers of quality such as HON-code certification.

  7. Validation Study of Waray Text Readability Instrument

    Science.gov (United States)

    Oyzon, Voltaire Q.; Corrales, Juven B.; Estardo, Wilfredo M., Jr.

    2015-01-01

    In 2012 the Leyte Normal University developed a computer software--modelled after the Spache Readability Formula (1953) made for English--made to help rank texts that can is used by teachers or research groups on selecting appropriate reading materials to support the DepEd's MTB-MLE program in Region VIII, in the Philippines. However,…

  8. Two-Dimensional Extreme Learning Machine

    Directory of Open Access Journals (Sweden)

    Bo Jia

    2015-01-01

    (BP networks. However, like many other methods, ELM is originally proposed to handle vector pattern while nonvector patterns in real applications need to be explored, such as image data. We propose the two-dimensional extreme learning machine (2DELM based on the very natural idea to deal with matrix data directly. Unlike original ELM which handles vectors, 2DELM take the matrices as input features without vectorization. Empirical studies on several real image datasets show the efficiency and effectiveness of the algorithm.

  9. Development of SMOG-Cro readability formula for healthcare communication and patient education.

    Science.gov (United States)

    Brangan, Sanja

    2015-03-01

    Effective communication shows a positive impact on patient satisfaction, compliance and medical outcomes, at the same time reducing the healthcare costs. Written information for patients needs to correspond to health literacy levels of the intended audiences. Readability formulas correlate well with the reading and comprehension tests but are considered an easier and quicker method to estimate a text difficulty. SMOG readability formula designed for English language needs to be modified if used for texts in other languages. The aim of this study was to develop a readability formula based on SMOG, that could be used to estimate text difficulty of written materials for patients in Croatian language. Contras- tive analysis of English and Croatian language covering a corpus of almost 100,000 running words showed clear linguis- tic differences in the number of polysyllabic words. The new formula, named SMOG-Cro, is presented as an equation: SMOG-Cro = 2 + √4+ syllables, with the score showing the number of years of education a person needs to be able to understand a piece of writing. The presented methodology could help in the development of readability formulas for other languages. We hope the results of this study are soon put into practice for more effective healthcare communication and patient education, and for development of a health literacy assessment tool in Croatian language.

  10. Readability assessment of online patient education materials from academic otolaryngology-head and neck surgery departments.

    Science.gov (United States)

    Svider, Peter F; Agarwal, Nitin; Choudhry, Osamah J; Hajart, Aaron F; Baredes, Soly; Liu, James K; Eloy, Jean Anderson

    2013-01-01

    The aim of this study was to compare the readability of online patient education materials among academic otolaryngology departments in the mid-Atlantic region, with the purpose of determining whether these commonly used online resources were written at a level readily understood by the average American. A readability analysis of online patient education materials was performed using several commonly used readability assessments including the Flesch Reading Ease Score, the Flesch-Kincaid Grade Level, Simple Measure of Gobbledygook, Gunning Frequency of Gobbledygook, the New Dale-Chall Test, the Coleman-Liau Index, the New Fog Count, the Raygor Readability Estimate, the FORCAST test, and the Fry Graph. Most patient education materials from these programs were written at or above an 11th grade reading level, considerably above National Institutes of Health guidelines for recommended difficulty. Patient educational materials from academic otolaryngology Web sites are written at too difficult a reading level for a significant portion of patients and can be simplified. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Readability Revisited? The Implications of Text Complexity

    Science.gov (United States)

    Wray, David; Janan, Dahlia

    2013-01-01

    The concept of readability has had a variable history, moving from a position where it was considered as a very important topic for those responsible for producing texts and matching those texts to the abilities and needs of learners, to its current declining visibility in the education literature. Some important work has been coming from the USA…

  12. Informed consent recall and comprehension in orthodontics: traditional vs improved readability and processability methods.

    Science.gov (United States)

    Kang, Edith Y; Fields, Henry W; Kiyak, Asuman; Beck, F Michael; Firestone, Allen R

    2009-10-01

    Low general and health literacy in the United States means informed consent documents are not well understood by most adults. Methods to improve recall and comprehension of informed consent have not been tested in orthodontics. The purposes of this study were to evaluate (1) recall and comprehension among patients and parents by using the American Association of Orthodontists' (AAO) informed consent form and new forms incorporating improved readability and processability; (2) the association between reading ability, anxiety, and sociodemographic variables and recall and comprehension; and (3) how various domains (treatment, risk, and responsibility) of information are affected by the forms. Three treatment groups (30 patient-parent pairs in each) received an orthodontic case presentation and either the AAO form, an improved readability form (MIC), or an improved readability and processability (pairing audio and visual cues) form (MIC + SS). Structured interviews were transcribed and coded to evaluate recall and comprehension. Significant relationships among patient-related variables and recall and comprehension explained little of the variance. The MIC + SS form significantly improved patient recall and parent recall and comprehension. Recall was better than comprehension, and parents performed better than patients. The MIC + SS form significantly improved patient treatment comprehension and risk recall and parent treatment recall and comprehension. Patients and parents both overestimated their understanding of the materials. Improving the readability of consent materials made little difference, but combining improved readability and processability benefited both patients' recall and parents' recall and comprehension compared with the AAO form.

  13. Operating System For Numerically Controlled Milling Machine

    Science.gov (United States)

    Ray, R. B.

    1992-01-01

    OPMILL program is operating system for Kearney and Trecker milling machine providing fast easy way to program manufacture of machine parts with IBM-compatible personal computer. Gives machinist "equation plotter" feature, which plots equations that define movements and converts equations to milling-machine-controlling program moving cutter along defined path. System includes tool-manager software handling up to 25 tools and automatically adjusts to account for each tool. Developed on IBM PS/2 computer running DOS 3.3 with 1 MB of random-access memory.

  14. Fuel element load/unload machine for the PEC reactor

    International Nuclear Information System (INIS)

    Clayton, K.F.

    1984-01-01

    GEC Energy Systems Limited are providing two fuel element load/unload machines for use in the Italian fast reactor programme. One will be used in the mechanism test facility (IPM) at Casaccia, to check the salient features of the machine operating in a sodium environment prior to the second machine being installed in the PEC Brasimone Reactor. The machine is used to handle fuel elements, control rods and other reactor components in the sodium-immersed core of the reactor. (U.K.)

  15. An evaluation of the readability of drinking water quality reports: a national assessment.

    Science.gov (United States)

    Roy, Siddhartha; Phetxumphou, Katherine; Dietrich, Andrea M; Estabrooks, Paul A; You, Wen; Davy, Brenda M

    2015-09-01

    The United States Environmental Protection Agency mandates that community water systems (or water utilities) provide annual consumer confidence reports (CCRs)--water quality reports--to their consumers. These reports encapsulate information regarding sources of water, detected contaminants, regulatory compliance, and educational material. These reports have excellent potential for providing the public with accurate information on the safety of tap water, but there is a lack of research on the degree to which the information can be understood by a large proportion of the population. This study evaluated the readability of a nationally representative sample of 30 CCRs, released between 2011 and 2013. Readability (or 'comprehension difficulty') was evaluated using Flesch-Kincaid readability tests. The analysis revealed that CCRs were written at the 11th-14th grade level, which is well above the recommended 6th-7th grade level for public health communications. The CCR readability ease was found to be equivalent to that of the Harvard Law Review journal. These findings expose a wide chasm that exists between current water quality reports and their effectiveness toward being understandable to US residents. Suggestions for reorienting language and scientific information in CCRs to be easily comprehensible to the public are offered.

  16. Recent fuel handling experience in Canada

    International Nuclear Information System (INIS)

    Welch, A.C.

    1991-01-01

    For many years, good operation of the fuel handling system at Ontario Hydro's nuclear stations has been taken for granted with the unavailability of the station arising from fuel handling system-related problems usually contributing less than one percent of the total unavailability of the stations. While the situation at the newer Hydro stations continues generally to be good (with the specific exception of some units at Pickering B) some specific and some general problems have caused significant loss of availability at the older plants (Pickering A and Bruce A). Generally the experience at the 600 MWe units in Canada has also continued to be good with Point Lepreau leading the world in availability. As a result of working to correct identified deficiencies, there were some changes for the better as some items of equipment that were a chronic source of trouble were replaced with improved components. In addition, the fuel handling system has been used three times as a delivery system for large-scale non destructive examination of the pressure tubes, twice at Bruce and once at Pickering and performing these inspections this way has saved many days of reactor downtime. Under COG there are several programs to develop improved versions of some of the main assemblies of the fuelling machine head. This paper will generally cover the events relating to Pickering in more detail but will describe the problems with the Bruce Fuelling Machine Bridges since the 600 MW 1P stations have a bridge drive arrangement that is somewhat similar to Bruce

  17. Readability Assessment of Online Uveitis Patient Education Materials.

    Science.gov (United States)

    Ayoub, Samantha; Tsui, Edmund; Mohammed, Taariq; Tseng, Joseph

    2017-12-29

    To evaluate the readability of online uveitis patient education materials. A Google search in November 2016 was completed using search term "uveitis" and "uveitis inflammation." The top 50 websites with patient-centered information were selected and analyzed for readability using the Flesch-Kincaid Grade Level (FKGL), Flesch Reading Ease Score (FRES), Gunning FOG Index (GFI), and Simple Measure of Gobbledygook (SMOG). Statistical analysis was performed with two-tailed t-tests. The mean word count of the top 50 websites was 1162.7 words, and averaged 16.2 words per sentence. For these websites, the mean FRES was 38.0 (range 4-66, SD = 12.0), mean FKGL was 12.3 (range 6.8-19, SD = 2.4), mean SMOG score was 14.4 (range 9.8-19, SD = 1.8), and the mean Gunning FOG index was 14.0 (range 8.6-19, SD = 2.0). The majority of online patient directed uveitis materials are at a higher reading level than that of the average American adult.

  18. CANDU-9/480-SEU fuel handling system assessment document

    International Nuclear Information System (INIS)

    Hwang, Jeong Ki; Jo, C. H.; Kim, H. M.; Morikawa, D. T.

    1996-11-01

    This report summarize the rationale for the CANDU 9 fuel handling system, and the design choices recommended for components of the system. Some of the design requirements applicable to the CANDU 9 480-SEU fuel handling design choices are described. These requirements imposed by the CANDU 9 project. And the design features for the key components of fuel handling system, such as the fuelling machine, the carriage, the new fuel transfer system and the irradiated fuel transfer system, are described. The carriage seismic load evaluations relevant to the design are contained in the appendices. The majority of the carriage components are acceptable, or will likely be acceptable with some redesign. The concept for the CANDU 9 fuel handling system is based on proven CANDU designs, or on improved CANDU technology. Although some development work must be done, the fuel handling concept is judged to be feasible for the CANDU 9 480-SEU reactor. (author). 2 refs

  19. Use of a New Set of Linguistic Features to Improve Automatic Assessment of Text Readability

    Science.gov (United States)

    Yoshimi, Takehiko; Kotani, Katsunori; Isahara, Hitoshi

    2012-01-01

    The present paper proposes and evaluates a readability assessment method designed for Japanese learners of EFL (English as a foreign language). The proposed readability assessment method is constructed by a regression algorithm using a new set of linguistic features that were employed separately in previous studies. The results showed that the…

  20. Enhancing the Radiologist-Patient Relationship through Improved Communication: A Quantitative Readability Analysis in Spine Radiology.

    Science.gov (United States)

    Hansberry, D R; Donovan, A L; Prabhu, A V; Agarwal, N; Cox, M; Flanders, A E

    2017-06-01

    More than 75 million Americans have less than adequate health literacy skills according to the National Center for Education Statistics. Readability scores are used as a measure of how well populations read and understand patient education materials. The purpose of this study was to assess the readability of Web sites dedicated to patient education for radiologic spine imaging and interventions. Eleven search terms relevant to radiologic spine imaging were searched on the public Internet, and the top 10 links for each term were collected and analyzed to determine readability scores by using 10 well-validated quantitative readability assessments from patient-centered education Web sites. The search terms included the following: x-ray spine, CT spine, MR imaging spine, lumbar puncture, kyphoplasty, vertebroplasty, discogram, myelogram, cervical spine, thoracic spine, and lumbar spine. Collectively, the 110 articles were written at an 11.3 grade level (grade range, 7.1-16.9). None of the articles were written at the American Medical Association and National Institutes of Health recommended 3rd-to-7th grade reading levels. The vertebroplasty articles were written at a statistically significant ( P readability scores of the articles and the American Medical Association and National Institutes of Health recommended guidelines, it is likely that many patients do not fully benefit from these resources. © 2017 by American Journal of Neuroradiology.

  1. Forensic scientists' conclusions: how readable are they for non-scientist report-users?

    Science.gov (United States)

    Howes, Loene M; Kirkbride, K Paul; Kelty, Sally F; Julian, Roberta; Kemp, Nenagh

    2013-09-10

    Scientists have an ethical responsibility to assist non-scientists to understand their findings and expert opinions before they are used as decision-aids within the criminal justice system. The communication of scientific expert opinion to non-scientist audiences (e.g., police, lawyers, and judges) through expert reports is an important but under-researched issue. Readability statistics were used to assess 111 conclusions from a proficiency test in forensic glass analysis. The conclusions were written using an average of 23 words per sentence, and approximately half of the conclusions were expressed using the active voice. At an average Flesch-Kincaid Grade level of university undergraduate (Grade 13), and Flesch Reading Ease score of difficult (42), the conclusions were written at a level suitable for people with some tertiary education in science, suggesting that the intended non-scientist readers would find them difficult to read. To further analyse the readability of conclusions, descriptive features of text were used: text structure; sentence structure; vocabulary; elaboration; and coherence and unity. Descriptive analysis supported the finding that texts were written at a level difficult for non-scientists to read. Specific aspects of conclusions that may pose difficulties for non-scientists were located. Suggestions are included to assist scientists to write conclusions with increased readability for non-scientist readers, while retaining scientific integrity. In the next stage of research, the readability of expert reports in their entirety is to be explored. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  2. The readability of pediatric patient education materials on the World Wide Web.

    Science.gov (United States)

    D'Alessandro, D M; Kingsley, P; Johnson-West, J

    2001-07-01

    Literacy is a national and international problem. Studies have shown the readability of adult and pediatric patient education materials to be too high for average adults. Materials should be written at the 8th-grade level or lower. To determine the general readability of pediatric patient education materials designed for adults on the World Wide Web (WWW). GeneralPediatrics.com (http://www.generalpediatrics.com) is a digital library serving the medical information needs of pediatric health care providers, patients, and families. Documents from 100 different authoritative Web sites designed for laypersons were evaluated using a built-in computer software readability formula (Flesch Reading Ease and Flesch-Kincaid reading levels) and hand calculation methods (Fry Formula and SMOG methods). Analysis of variance and paired t tests determined significance. Eighty-nine documents constituted the final sample; they covered a wide spectrum of pediatric topics. The overall Flesch Reading Ease score was 57.0. The overall mean Fry Formula was 12.0 (12th grade, 0 months of schooling) and SMOG was 12.2. The overall Flesch-Kincaid grade level was significantly lower (Peducation materials on the WWW are not written at an appropriate reading level for the average adult. We propose that a practical reading level and how it was determined be included on all patient education materials on the WWW for general guidance in material selection. We discuss suggestions for improved readability of patient education materials.

  3. Formalising the Safety of Java, the Java Virtual Machine and Java Card

    OpenAIRE

    Hartel, Pieter H.; Moreau, Luc

    2001-01-01

    We review the existing literature on Java safety, emphasizing formal approaches, and the impact of Java safety on small footprint devices such as smart cards. The conclusion is that while a lot of good work has been done, a more concerted effort is needed to build a coherent set of machine readable formal models of the whole of Java and its implementation. This is a formidable task but we believe it is essential to building trust in Java safety, and thence to achieve ITSEC level 6 or Common C...

  4. What parents are reading about laryngomalacia: Quality and readability of internet resources on laryngomalacia.

    Science.gov (United States)

    Corredera, Erica; Davis, Kara S; Simons, Jeffrey P; Jabbour, Noel

    2018-05-01

    The goal of this study is to measure the quality and readability of websites related to laryngomalacia, and to compare the quality and readability scores for the sites accessed through the most popular search engines. Laryngomalacia is a common diagnosis in children but is often difficult for parents to comprehend. As information available on the internet is unregulated, the quality and readability of this information may vary. An advanced search on Google, Yahoo, and Bing was conducted using the terms "laryngomalacia" OR "soft larynx" OR "floppy voice box." The first ten websites meeting inclusion and exclusion criteria were evaluated, for each search engine. Quality and readability were assessed using the DISCERN criteria and the Flesch reading ease scoring (FRES) and Flesch-Kincaid grade level (FKGL) tests, respectively. The top 10 hits on each search engine yielded 15 unique web pages. The median DISCERN score (out of a possible high-score of 80) was 48.5 (SD 12.6). The median USA grade-level estimated by the FKGL was 11.3 (SD 1.4). Only one website (6.7%), had a readability score in the optimal range of 6th to 8th grade reading level. DISCERN scores did not correlate with FKGL scores (r = 0.10). Online information discussing laryngomalacia often varies in quality and may not be easily comprehensible to the public. It is important for healthcare professionals to understand the quality of health information accessible to patients as it may influence medical decision-making by patient families. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. How Readability and Topic Incidence Relate to Performance on Mathematics Story Problems in Computer-Based Curricula

    Science.gov (United States)

    Walkington, Candace; Clinton, Virginia; Ritter, Steven N.; Nathan, Mitchell J.

    2015-01-01

    Solving mathematics story problems requires text comprehension skills. However, previous studies have found few connections between traditional measures of text readability and performance on story problems. We hypothesized that recently developed measures of readability and topic incidence measured by text-mining tools may illuminate associations…

  6. An experimental study on the readability of the digital images in the furcal bone defects

    International Nuclear Information System (INIS)

    Oh, Bong Hyeon; Hwang, Eui Hwan; Lee, Sang Rae

    1995-01-01

    The aim of this study was to evaluate and compare observer performance between conventional radiographs and their digitized images for the detection of bone loss in the bifurcation of mandibular first molar. One dried human mandible with minimal periodontal bone loss around the first molar was selected and serially enlarged 27 step defects were prepared in the bifurcation area. The mandible was radiographed with exposure time of 0.12, 0.20, 0.25, 0.32, 0.40, 0.64 seconds, after each successive step in the preperation and all radiographs were digitized with IBM-PC/32 bit-Dx compatible, video camera (VM-S8200, Hitachi Co., Japan), and color monitor (Multisync 3D, NEC, Japan). Sylvia Image Capture Board for the ADC (analog to digital converter) was used. The following results obtained: 1. In the conventional radiographs, the mean score of the readability was higher at the condition of exposure time with 0.32 second. Also, as the size of artificial lesion was increased, the readability of radiographs was elevated (p<0.05). 2. In the digital images, the mean score of the readability was higher at the condition of exposure time with 0.40 second. Also, as the size of artificial lesion was increased, the readability of digital images was elevated (p<0.05). 3. At the same exposure time, the mean scores of readability were mostly higher in the digitized images. As the exposure time was increased, the digital images were superior to radiographs in readability. 4. As the size of lesion was changed, the digital images were superior to radiographs in detecting small lesion. 5. The coefficient of variation of mean score has no significant difference between digital images and radiographs.

  7. Tools for Assessing Readability of Statistics Teaching Materials

    Science.gov (United States)

    Lesser, Lawrence; Wagler, Amy

    2016-01-01

    This article provides tools and rationale for instructors in math and science to make their assessment and curriculum materials (more) readable for students. The tools discussed (MSWord, LexTutor, Coh-Metrix TEA) are readily available linguistic analysis applications that are grounded in current linguistic theory, but present output that can…

  8. 40 CFR 63.463 - Batch vapor and in-line cleaning machine standards.

    Science.gov (United States)

    2010-07-01

    .... (3) Each cleaning machine shall have an automated parts handling system capable of moving parts or... of parts through removal of cleaned parts. (4) Each vapor cleaning machine shall be equipped with a...) and appendix A to this part. (2) Each owner or operator of a batch vapor cleaning machine with a...

  9. Contents and readability of currently used surgical/ procedure ...

    African Journals Online (AJOL)

    Conclusion: The content of majority of the informed consent forms used in Nigerian tertiary health institutions are poor and their readability scores are not better than those used in developed parts of the world. Health Institutions in Nigeria should revise their informed consent forms to improve their contents and do a usability ...

  10. Hoisting appliances and fuel handling equipment at nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1988-12-31

    The guide is followed by the Finnish Centre for Radiation and Nuclear Safety (STUK) in regulating hoisting and handling equipment Class 3 at nuclear facilities. The guide is applied e.g. to the following equipment: reactor building overhead cranes, hoisting appliances at nuclear fuel storages, fuel handling machines, other hoisting appliances, which because of nuclear safety aspects are classified in Safety Class 3, and load-bearing devices connected with the above equipment, such as replaceable hoisting tools and auxiliary lifting devices. The regulating of hoisting and handling equipment comprises the following stages: handling of preliminary and final safety analysis reports, inspection of the construction plan, supervision of fabrication and construction inspection, and supervision of initial start-up and commissioning inspection. 36 refs. Translation. The original text is published under the same guide number. The guide is valid from 5 January 1987 and will be in force until further notice.

  11. Comparative Readability of Shoulder and Elbow Patient Education Materials within Orthopaedic Websites.

    Science.gov (United States)

    Beutel, Bryan G; Danna, Natalie R; Melamed, Eitan; Capo, John T

    2015-12-01

    There is growing concern that the readability of online orthopaedic patient education materials are too difficult for the general public to fully understand. It is recommended that this information be at the sixth grade reading level or lower. This study compared the readability of shoulder and elbow education articles from the American Academy of Orthopaedic Surgeons (AAOS) and American Society for Surgery of the Hand (ASSH) websites. Seventy-six patient education articles from the AAOS and ASSH concerning shoulder and elbow disorders were evaluated. Each article was assessed for the number of years since its last update, word count, percentage of passive sentences, Flesch Reading Ease score, Flesch-Kincaid grade level, Simple Measure of Gobbledygook (SMOG) grade, and New Dale-Chall grade level. Only one article was at or below the sixth grade reading level. The AAOS and ASSH articles had the following respective scores: a mean Flesch Reading Ease score of 54.3 and 51.8, Flesch-Kincaid grade level of 9.4 and 10.3, SMOG grade of 8.5 and 9.4, and New Dale-Chall grade of 10.4 and 11.0. Articles from the AAOS were longer (p education materials regarding the shoulder and elbow on the AAOS and ASSH websites have readability scores above the recommended reading level. These may be too challenging for the majority of patients to read and consequently serve as a barrier to proper patient education. Reducing the percentage of passive sentences may serve as a novel target for improving readability.

  12. Dr Google: The readability and accuracy of patient education websites for Graves' disease treatment.

    Science.gov (United States)

    Purdy, Amanda C; Idriss, Almoatazbellah; Ahern, Susan; Lin, Elizabeth; Elfenbein, Dawn M

    2017-11-01

    National guidelines emphasize the importance of incorporating patient preferences into the recommendations for the treatment of Graves' disease. Many patients use the Internet to obtain health information, and search results can affect their treatment decisions. This study compares the readability and accuracy of patient-oriented online resources for the treatment of Graves' disease by website affiliation and treatment modality. A systematic Internet search was used to identify the top websites discussing the treatment of Graves' disease. Readability was measured using 5 standardized tests. Accuracy was assessed by a blinded, expert panel, which scored the accuracy of sites on a scale of 1 to 5. Mean readability and accuracy scores were compared among website affiliations and treatment modalities. We identified 13 unique websites, including 2 academic, 2 government, 5 nonprofit, and 4 private sites. There was a difference in both readability (mean 13.2, range 9.1-15.7, P = .003) and accuracy (mean 4.04, range 2.75-4.50, P = .019) based on website affiliation. Government sites (mean readability 11.1) were easier to read than academic (14.3, P < .01), nonprofit (13.9, P < .01), and private sites (13.5, P < .05). Academic sites (mean accuracy 4.50) were more accurate than private sites (3.56, P < .05). Online patient resources for the treatment of Graves' disease are written at an inappropriately high reading level. Academic sites contain both the most accurate and the most difficult to read information. Private sites represented the majority of our top results but contained the least accurate information. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Clozing in on readability : How linguistic features affect and predict text comprehension and on-line processing

    NARCIS (Netherlands)

    Kleijn, S.

    2018-01-01

    Is my text comprehensible for my audience? It is a question publishers, organizations and governments struggle with and it is a question that readability formulae proclaim to solve. With a press of a button the readability of a text is assessed and users know whether texts are suited for their

  14. Readability of online patient education materials for velopharyngeal insufficiency.

    Science.gov (United States)

    Xie, Deborah X; Wang, Ray Y; Chinnadurai, Sivakumar

    2018-01-01

    Evaluate the readability of online and mobile application health information about velopharyngeal insufficiency (VPI). Top website and mobile application results for search terms "velopharyngeal insufficiency", "velopharyngeal dysfunction", "VPI", and "VPD" were analyzed. Readability was determined using 10 algorithms with Readability Studio Professional Edition (Oleander Software Ltd; Vandalia, OH). Subgroup analysis was performed based on search term and article source - academic hospital, general online resource, peer-reviewed journal, or professional organization. 18 unique articles were identified. Overall mean reading grade level was a 12.89 ± 2.9. The highest reading level among these articles was 15.47-approximately the level of a college senior. Articles from "velopharyngeal dysfunction" had the highest mean reading level (13.73 ± 2.11), above "velopharyngeal insufficiency" (12.30 ± 1.56) and "VPI" (11.66 ± 1.70). Articles from peer-reviewed journals had the highest mean reading level (15.35 ± 2.79), while articles from academic hospitals had the lowest (12.81 ± 1.66). There were statistically significant differences in reading levels between the different search terms (P reading level guidelines, online patient education materials for VPI are disseminated with language too complex for most readers. There is also a lack of VPI-related mobile application data available for patients. Patients will benefit if future updates to websites and disseminated patient information are undertaken with health literacy in mind. Future studies will investigate patient comprehension of these materials. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Readability Analysis of the Package Leaflets for Biological Medicines Available on the Internet Between 2007 and 2013: An Analytical Longitudinal Study.

    Science.gov (United States)

    Piñero-López, María Ángeles; Modamio, Pilar; Lastra, Cecilia F; Mariño, Eduardo L

    2016-05-25

    The package leaflet included in the packaging of all medicinal products plays an important role in the transmission of medicine-related information to patients. Therefore, in 2009, the European Commission published readability guidelines to try to ensure that the information contained in the package leaflet is understood by patients. The main objective of this study was to calculate and compare the readability levels and length (number of words) of the package leaflets for biological medicines in 2007, 2010, and 2013. The sample of this study included 36 biological medicine package leaflets that were downloaded from the European Medicines Agency website in three different years: 2007, 2010, and 2013. The readability of the selected package leaflets was obtained using the following readability formulas: SMOG grade, Flesch-Kincaid grade level, and Szigriszt's perspicuity index. The length (number of words) of the package leaflets was also measured. Afterwards, the relationship between these quantitative variables (three readability indexes and length) and categorical (or qualitative) variables were analyzed. The categorical variables were the year when the package leaflet was downloaded, the package leaflet section, type of medicine, year of authorization of biological medicine, and marketing authorization holder. The readability values of all the package leaflets exceeded the sixth-grade reading level, which is the recommended value for health-related written materials. No statistically significant differences were found between the three years of study in the readability indexes, although differences were observed in the case of the length (P=.002), which increased over the study period. When the relationship between readability indexes and length and the other variables was analyzed, statistically significant differences were found between package leaflet sections (Preadability indexes (SMOG grade and Flesch-Kincaid grade level: r(2)=.92; SMOG grade and Szigriszt

  16. Robotic refueling machine

    International Nuclear Information System (INIS)

    Challberg, R.C.; Jones, C.R.

    1996-01-01

    One of the longest critical path operations performed during the outage is removing and replacing the fuel. A design is currently under development for a refueling machine which would allow faster, fully automated operation and would also allow the handling of two fuel assemblies at the same time. This design is different from current designs, (a) because of its lighter weight, making increased acceleration and speed possible, (b) because of its control system which makes locating the fuel assembly more dependable and faster, and (c) because of its dual handling system allowing simultaneous fuel movements. The new design uses two robotic arms to span a designated area of the vessel and the fuel storage area. Attached to the end of each robotic arm is a lightweight telescoping mast with a pendant attached to the end of each mast. The pendant acts as the base unit, allowing attachment of any number of end effectors depending on the servicing or inspection operation. Housed within the pendant are two television cameras used for the positioning control system. The control system is adapted from the robotics field using the technology known as machine vision, which provides both object and character recognition techniques to enable relative position control rather than absolute position control as in past designs. The pendant also contains thrusters that are used for fast, short distance, precise positioning. The new refueling machine system design is capable of a complete off load and reload of an 872 element core in about 5.3 days compared to 13 days for a conventional system

  17. 49 CFR 573.4 - Definitions.

    Science.gov (United States)

    2010-10-01

    ... readable by machine. If readable by machine, the submitting party must obtain written confirmation from the Office of Defects Investigation immediately prior to submission that the machine is readily available to... addition, all coded information must be accompanied by an explanation of the codes used. Replacement...

  18. Readability of Orthopaedic Patient-reported Outcome Measures: Is There a Fundamental Failure to Communicate?

    Science.gov (United States)

    Perez, Jorge L; Mosher, Zachary A; Watson, Shawna L; Sheppard, Evan D; Brabston, Eugene W; McGwin, Gerald; Ponce, Brent A

    2017-08-01

    Patient-reported outcome measures (PROMs) are increasingly used to quantify patients' perceptions of functional ability. The American Medical Association and NIH suggest patient materials be written at or below 6th to 8th grade reading levels, respectively, yet one recent study asserts that few PROMs comply with these recommendations, and suggests that the majority of PROMs are written at too high of a reading level for self-administered patient use. Notably, this study was limited in its use of only one readability algorithm, although there is no commonly accepted, standard readability algorithm for healthcare-related materials. Our study, using multiple readability equations and heeding equal weight to each, hopes to yield a broader, all-encompassing estimate of readability, thereby offering a more accurate assessment of the readability of orthopaedic PROMS. (1) What proportion of orthopaedic-related PROMs and orthopaedic-related portions of the NIH Patient Reported Outcomes Measurement Information System (PROMIS ® ) are written at or below the 6th and 8th grade levels? (2) Is there a correlation between the number of questions in the PROM and reading level? (3) Using systematic edits based on guidelines from the Centers for Medicare and Medicaid Services, what proportion of PROMs achieved American Medical Association and NIH-recommended reading levels? Eighty-six (86) independent, orthopaedic and general wellness PROMs, drawn from commonly referenced orthopaedic websites and prior studies, were chosen for analysis. Additionally, owing to their increasing use in orthopaedics, four relevant short forms, and 11 adult, physical health question banks from the PROMIS ® , were included for analysis. All documents were analyzed for reading grade levels using 19 unique readability algorithms. Descriptive statistics were performed using SPSS Version 22.0. The majority of the independent PROMs (64 of 86; 74%) were written at or below the 6th grade level, with 81 of 86

  19. Readability assessment of internet-based patient education materials related to mammography for breast cancer screening.

    Science.gov (United States)

    AlKhalili, Rend; Shukla, Pratik A; Patel, Ronak H; Sanghvi, Saurin; Hubbi, Basil

    2015-03-01

    The US Department of Health and Human Services (USDHHS) recommends that Internet-based patient education materials (IPEMs) be written below the sixth-grade reading level to target the average American adult. This study was designed to determine the readability of IPEMs regarding mammography for breast cancer screening. Three-hundred mammography-related Web sites were reviewed for IPEMs. Forty-two IPEMs that met the Health on the Net Foundation Code of Conduct were assessed for readability level with four readability indices that use existing algorithms based on word and sentence length to quantitatively analyze Internet sources for language intricacy including the following: Flesch-Kincaid Grade Level (FKGL), Flesch Reading Ease Score (FRES), Simple Measure of Gobbledygook (SMOG), and Gunning Frequency of Gobbledygook (Gunning FOG; GFOG). Results were compared to national recommendations, and intergroup analysis was performed. No IPEMs (0%) regarding mammography were written at or below the sixth-grade reading level, based on FKGL. The mean readability scores were as follows: FRES, 49.04 ± 10.62; FKGL, 10.71 ± 2.01; SMOG, 13.33 ± 1.67; and Gunning FOG, 14.32 ± 2.18. These scores indicate that the readability of mammography IPEMs is written at a "difficult" level, significantly above the recommended sixth-grade reading level (P < .05) determined by the USDHHS. IPEMs related to mammography are written well above the recommended sixth-grade level and likely reflect other IPEMs in diagnostic radiology. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  20. The Readability of Electronic Cigarette Health Information and Advice: A Quantitative Analysis of Web-Based Information.

    Science.gov (United States)

    Park, Albert; Zhu, Shu-Hong; Conway, Mike

    2017-01-06

    The popularity and use of electronic cigarettes (e-cigarettes) has increased across all demographic groups in recent years. However, little is currently known about the readability of health information and advice aimed at the general public regarding the use of e-cigarettes. The objective of our study was to examine the readability of publicly available health information as well as advice on e-cigarettes. We compared information and advice available from US government agencies, nongovernment organizations, English speaking government agencies outside the United States, and for-profit entities. A systematic search for health information and advice on e-cigarettes was conducted using search engines. We manually verified search results and converted to plain text for analysis. We then assessed readability of the collected documents using 4 readability metrics followed by pairwise comparisons of groups with adjustment for multiple comparisons. A total of 54 documents were collected for this study. All 4 readability metrics indicate that all information and advice on e-cigarette use is written at a level higher than that recommended for the general public by National Institutes of Health (NIH) communication guidelines. However, health information and advice written by for-profit entities, many of which were promoting e-cigarettes, were significantly easier to read. A substantial proportion of potential and current e-cigarette users are likely to have difficulty in fully comprehending Web-based health information regarding e-cigarettes, potentially hindering effective health-seeking behaviors. To comply with NIH communication guidelines, government entities and nongovernment organizations would benefit from improving the readability of e-cigarettes information and advice. ©Albert Park, Shu-Hong Zhu, Mike Conway. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 06.01.2017.

  1. Influence of vocabulary and sentence complexity and passive voice on the readability of consumer-oriented mental health information on the Internet.

    Science.gov (United States)

    Ownby, Raymond L

    2005-01-01

    Searching for health care information is one of the most common uses of the Internet by the elderly. Our earlier research showed that health care information websites may present information at levels of readability that are excessively difficult for many potential users. This study investigated the influence of several aspects of readability (vocabulary and sentence complexity and use of passive voice construction) on overall readability at several different levels of readability. Results show that easier to read sites could be differentiated most consistently from more difficult sites by vocabulary complexity. Comparison of the easiest and most difficult sites in several cases showed that sentence complexity and passive voice may also be important. These results can provide guidance for those interested in improving the readability of web sites that provide mental health information for consumers.

  2. An Analysis of the Readability of Financial Accounting Textbooks.

    Science.gov (United States)

    Smith, Gerald; And Others

    1981-01-01

    The Flesch formula was used to calculate the readability of 15 financial accounting textbooks. The 15 textbooks represented introductory, intermediate, and advanced levels and also were classified by five different publishers. Two-way analysis of variance and Tukey's post hoc analysis revealed some significant differences. (Author/CT)

  3. Design of remote handling equipment for the ITER NBI

    Energy Technology Data Exchange (ETDEWEB)

    Oka, Kiyoshi; Tada, Eisuke [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1999-08-01

    The ITER machine has three Neutral Beam Injectors (NBIs) placed tangential to the plasma at a minimum radius of 6.25 m. During operation, neutrons produced by the D-T reactions will irradiate the NBI structure and it will become radioactive. Radiation levels will be such that all subsequent maintenance of the NBIs must be carried out remotely. The presence of tritium and possibly radioactive dust requires that precautions be taken during maintenance to prevent the escape of these contaminants beyond the prescribed boundaries. The scope of this task is both the development of remote maintenance procedures and the design of the remote handling equipment to handle the NBIs. This report describes the design of remote handling tools for the ion source and its filaments, transfer cask, maintenance time, manufacturing schedule and cost estimation. (author)

  4. Readability of patient information pamphlets in urogynecology.

    Science.gov (United States)

    Reagan, Krista M L; O'Sullivan, David M; Harvey, David P; Lasala, Christine A

    2015-01-01

    The purpose of this study was to determine the reading level of frequently used patient information pamphlets and documents in the field of urogynecology. Urogynecology pamphlets were identified from a variety of sources. Readability was determined using 4 different accepted formulas: the Flesch-Kincaid Grade Level, the simple measure of gobbledygook Index, the Coleman-Liau Index, and the Gunning Fog index. The scores were calculated using an online calculator (http://www.readability-score.com). Descriptive statistics were used for analysis. The average of the 4 scores was calculated for each pamphlet. Subsequently, Z-scores were used to standardize the averages between the reading scales. Of the 40 documents reviewed, only a single pamphlet met the National Institutes of Health-recommended reading level. This document was developed by the American Urological Association and was specifically designated as a "Low-Literacy Brochure." The remainder of the patient education pamphlets, from both industry-sponsored and academic-sponsored sources, consistently rated above the recommended reading level for maximum comprehension. The majority of patient education pamphlets, from both industry-sponsored and academic-sponsored sources, are above the reading level recommended by the National Institutes of Health for maximum patient comprehension. Future work should be done to improve the educational resources available to patients by simplifying the verbiage in these documents.

  5. A quantitative readability analysis of patient education resources from gastroenterology society websites.

    Science.gov (United States)

    Hansberry, David R; Patel, Sahil R; Agarwal, Prateek; Agarwal, Nitin; John, Elizabeth S; John, Ann M; Reynolds, James C

    2017-06-01

    The lay public frequently access and rely on online information as a source of their medical knowledge. Many medical societies are unaware of national patient education material guidelines and subsequently fail to meet them. The goal of the present study was to evaluate the readability of patient education materials within the medical field of gastroenterology. Two hundred fourteen articles pertaining to patient education materials were evaluated with ten well-established readability scales. The articles were available on the websites for the American College of Gastroenterology (ACG), the American Gastroenterological Association (AGA), the American Society of Gastrointestinal Endoscopy (ASGE), the British Society of Gastroenterology (BSG), and the NIH section National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK). One-way analysis of variance (ANOVA) and Tukey's honest significant difference (HSD) post hoc analysis were conducted to determine any differences in level of readability between websites. The 214 articles were written at an 11.8 ± 2.1 grade level with a range of 8.0 to 16.0 grade level. A one-way ANOVA and Tukey's HSD post hoc analysis determined the ACG was written at a significantly (p gastroenterology content.

  6. Gradient Boosting Machines, A Tutorial

    Directory of Open Access Journals (Sweden)

    Alexey eNatekin

    2013-12-01

    Full Text Available Gradient boosting machines are a family of powerful machine-learning techniques that have shown considerable success in a wide range of practical applications. They are highly customizable to the particular needs of the application, like being learned with respect to different loss functions. This article gives a tutorial introduction into the methodology of gradient boosting methods. A theoretical information is complemented with many descriptive examples and illustrations which cover all the stages of the gradient boosting model design. Considerations on handling the model complexity are discussed. A set of practical examples of gradient boosting applications are presented and comprehensively analyzed.

  7. Readability of Informed Consent Documents at University Counseling Centers

    Science.gov (United States)

    Lustgarten, Samuel D.; Elchert, Daniel M.; Cederberg, Charles; Garrison, Yunkyoung L.; Ho, Y. C. S.

    2017-01-01

    The extent to which clients understand the nature and anticipated course of therapy is referred to as informed consent. Counseling psychologists often provide informed consent documents to enhance the education of services and for liability purposes. Professionals in numerous health care settings have evaluated the readability of their informed…

  8. Superphenix 1 primary handling system fabrication and testing

    International Nuclear Information System (INIS)

    Branchu, J.; Ebbinghaus, K.; Gigarel, C.

    1985-01-01

    Primary handling covers the operations performed for spent fuel removal, new fuel insertion, and the insodium storage outside the new or spent fuel vessel. This equipment typifies many of the difficulties encountered with the project as a whole: fabrication coordination when several countries are involved and design and construction of very large, relatively complex components. Detailed design studies were mainly influenced by thermal and seismic requirements, as applicable to sodium-immersed structures. Where possible, well-tried mechanical solutions were used, but widely differing techniques were involved, ranging from the high precision fabrication of structures and mechanisms comprising numerous component parts, implying complex machining operations. No particular problems were encountered during the sodium testing of the primary handling equipment. Trends for the 1500-MW (electric) breeder include investigation of the advisability of fuel storage in the core lattice and the possibility of handling system simplification

  9. Concept Design of the Payload Handling Manipulator System. [space shuttle orbiters

    Science.gov (United States)

    1975-01-01

    The design, requirements, and interface definition of a remote manipulator system developed to handle orbiter payloads are presented. End effector design, control system concepts, and man-machine engineering are considered along with crew station requirements and closed circuit television system performance requirements.

  10. Readability, complexity, and suitability analysis of online lymphedema resources.

    Science.gov (United States)

    Tran, Bao Ngoc N; Singh, Mansher; Lee, Bernard T; Rudd, Rima; Singhal, Dhruv

    2017-06-01

    Over 72% of Americans use online health information to assist in health care decision-making. Previous studies of lymphedema literature have focused only on reading level of patient-oriented materials online. Findings indicate they are too advanced for most patients to comprehend. This, more comprehensive study, expands the previous analysis to include critical elements of health materials beyond readability using assessment tools to report on the complexity and density of data as well as text design, vocabulary, and organization. The top 10 highest ranked websites on lymphedema were identified using the most popular search engine (Google). Website content was analyzed for readability, complexity, and suitability using Simple Measure of Gobbledygook, PMOSE/iKIRSCH, and Suitability Assessment of Materials (SAM), respectively. PMOSE/iKIRSCH and SAM were performed by two independent raters. Fleiss' kappa score was calculated to ensure inter-rater reliability. Online lymphedema literature had a reading grade level of 14.0 (SMOG). Overall complexity score was 6.7 (PMOSE/iKIRSCH) corresponding to "low" complexity and requiring a 8th-12th grade education. Fleiss' kappa score was 80% (P = 0.04, "substantial" agreement). Overall suitability score was 45% (SAM) correlating to the lowest level of "adequate" suitability. Fleiss' kappa score was 76% (P = 0.06, "substantial" agreement). Online resources for lymphedema are above the recommended levels for readability and complexity. The suitability level is barely adequate for the intended audience. Overall, these materials are too sophisticated for the average American adult, whose literacy skills are well documented. Further efforts to revise these materials are needed to improve patient comprehension and understanding. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Reassessing the Accuracy and Use of Readability Formulae

    Science.gov (United States)

    Janan, Dahlia; Wray, David

    2014-01-01

    Purpose: The purpose of the study is to review readability formulae and offer a critique, based on a comparison of the grading of a variety of texts given by six well-known formulae. Methodology: A total of 64 texts in English were selected either by or for native English speaking children aged between six and 11 years. Each text was assessed…

  12. Polyadenylated Sequencing Primers Enable Complete Readability of PCR Amplicons Analyzed by Dideoxynucleotide Sequencing

    Directory of Open Access Journals (Sweden)

    Martin Beránek

    2012-01-01

    Full Text Available Dideoxynucleotide DNA sequencing is one of the principal procedures in molecular biology. Loss of an initial part of nucleotides behind the 3' end of the sequencing primer limits the readability of sequenced amplicons. We present a method which extends the readability by using sequencing primers modified by polyadenylated tails attached to their 5' ends. Performing a polymerase chain reaction, we amplified eight amplicons of six human genes (AMELX, APOE, HFE, MBL2, SERPINA1 and TGFB1 ranging from 106 bp to 680 bp. Polyadenylation of the sequencing primers minimized the loss of bases in all amplicons. Complete sequences of shorter products (AMELX 106 bp, SERPINA1 121 bp, HFE 208 bp, APOE 244 bp, MBL2 317 bp were obtained. In addition, in the case of TGFB1 products (366 bp, 432 bp, and 680 bp, respectively, the lengths of sequencing readings were significantly longer if adenylated primers were used. Thus, single strand dideoxynucleotide sequencing with adenylated primers enables complete or near complete readability of short PCR amplicons.

  13. Evaluation of Quality and Readability of Health Information Websites Identified through India's Major Search Engines.

    Science.gov (United States)

    Raj, S; Sharma, V L; Singh, A J; Goel, S

    2016-01-01

    Background. The available health information on websites should be reliable and accurate in order to make informed decisions by community. This study was done to assess the quality and readability of health information websites on World Wide Web in India. Methods. This cross-sectional study was carried out in June 2014. The key words "Health" and "Information" were used on search engines "Google" and "Yahoo." Out of 50 websites (25 from each search engines), after exclusion, 32 websites were evaluated. LIDA tool was used to assess the quality whereas the readability was assessed using Flesch Reading Ease Score (FRES), Flesch-Kincaid Grade Level (FKGL), and SMOG. Results. Forty percent of websites (n = 13) were sponsored by government. Health On the Net Code of Conduct (HONcode) certification was present on 50% (n = 16) of websites. The mean LIDA score (74.31) was average. Only 3 websites scored high on LIDA score. Only five had readability scores at recommended sixth-grade level. Conclusion. Most health information websites had average quality especially in terms of usability and reliability and were written at high readability levels. Efforts are needed to develop the health information websites which can help general population in informed decision making.

  14. Health literacy and the Internet: a study on the readability of Australian online health information.

    Science.gov (United States)

    Cheng, Christina; Dunn, Matthew

    2015-08-01

    Almost 80% of Australian Internet users seek out health information online so the readability of this information is important. This study aimed to evaluate the readability of Australian online health information and determine if it matches the average reading level of Australians. Two hundred and fifty-one web pages with information on 12 common health conditions were identified across sectors. Readability was assessed by the Flesch-Kincaid (F-K), Simple Measure of Gobbledygook (SMOG) and Flesch Reading Ease (FRE) formulas, with grade 8 adopted as the average Australian reading level. The average reading grade measured by F-K and SMOG was 10.54 and 12.12 respectively. The mean FRE was 47.54, a 'difficult-to-read' score. Only 0.4% of web pages were written at or below grade 8 according to SMOG. Information on dementia was the most difficult to read overall, while obesity was the most difficult among government websites. The findings suggest that the readability of Australian health websites is above the average Australian levels of reading. A quantifiable guideline is needed to ensure online health information accommodates the reading needs of the general public to effectively use the Internet as an enabler of health literacy. © 2015 Public Health Association of Australia.

  15. Computerised programming of the Dragon reactor fuel handling operations

    International Nuclear Information System (INIS)

    Butcher, P.

    1976-11-01

    Two suites of FORTRAN IV computer programs have been written to produce check lists for the operation of the two remote control fuel handling machines of the Dragon Reactor. This document describes the advantages of these programs over the previous manual system of writing check lists, and provides a detailed guide to the programs themselves. (author)

  16. A Perspective on Equipment Design for Fusion Remote Handling

    International Nuclear Information System (INIS)

    Mills, S.; Haist, B.; Hamilton, D.

    2006-01-01

    For 8 years, JET remote operations have become more capable and confident. Many tasks have been successfully completed, even those never intended to be remote maintenance activities. The general approach to the provision of remote handling equipment at JET has been the preferred use of commercially-off-the-shelf equipment. In the areas of electrical, electronic, software and control this approach has been generally achievable. However, in the area of mechanical equipment it has been more difficult. In particular the RH tooling has been almost entirely bespoke as its requirements are highly sensitive to the design of the JET component being handled and there are many design variations. Hence, JET has required the design and manufacture of over 700 types of bespoke RH equipment. This paper will discuss the experience of introducing and developing remote handling mechanical equipment for JET. The paper will cover the relationship between the remote handling equipment and the JET component design and the potential for improving the design function. A major lesson from the introduction of remote handling to JET has been demonstration of the very close interdependency of the design of JET components with design of remote handling tooling. The JET remote handling manual was originally introduced as the vehicle to ensure remote handling compatibility by the introduction of standards. Experience has shown that in general the remote handling manual approach has been insufficient. Future fusion machines will be much more complex than JET and will demand even greater remote handling compatibility. This paper will discuss possible methods for improving this process. Equipment operating in a high radiation environment must be dependable It may spend part of its time in areas that would be extremely difficult to recover from in the case of failure. The equipment may also have a high duty cycle to minimise shutdown times and probably cannot be manually inspected on a frequent

  17. Visible Machine Learning for Biomedicine.

    Science.gov (United States)

    Yu, Michael K; Ma, Jianzhu; Fisher, Jasmin; Kreisberg, Jason F; Raphael, Benjamin J; Ideker, Trey

    2018-06-14

    A major ambition of artificial intelligence lies in translating patient data to successful therapies. Machine learning models face particular challenges in biomedicine, however, including handling of extreme data heterogeneity and lack of mechanistic insight into predictions. Here, we argue for "visible" approaches that guide model structure with experimental biology. Copyright © 2018. Published by Elsevier Inc.

  18. Multi Canister Overpack (MCO) Handling Machine - Independent Review of Seismic Structural Analysis

    International Nuclear Information System (INIS)

    SWENSON, C.E.

    2000-01-01

    The following separate reports and correspondence pertains to the independent review of the seismic analysis. The original analysis was performed by GEC-Alsthom Engineering Systems Limited (GEC-ESL) under subcontract to Foster-Wheeler Environmental Corporation (FWEC) who was the prime integration contractor to the Spent Nuclear Fuel Project for the Multi-Canister Overpack (MCO) Handling Machine (MHM). The original analysis was performed to the Design Basis Earthquake (DBE) response spectra using 5% damping as required in specification, HNF-S-0468 for the 90% Design Report in June 1997. The independent review was performed by Fluor-Daniel (Irvine) under a separate task from their scope as Architect-Engineer of the Canister Storage Building (CSB) in 1997. The comments were issued in April 1998. Later in 1997, the response spectra of the Canister Storage Building (CSB) was revised according to a new soil-structure interaction analysis and accordingly revised the response spectra for the MHM and utilized 7% damping in accordance with American Society of Mechanical Engineers (ASME) NOG-1, ''Rules for Construction of Overhead and Gantry Cranes (Top Running Bridge, Multiple Girder).'' The analysis was re-performed to check critical areas but because manufacturing was underway, designs were not altered unless necessary. FWEC responded to SNF Project correspondence on the review comments in two separate letters enclosed. The dispositions were reviewed and accepted. Attached are supplier source surveillance reports on the procedures and process by the engineering group performing the analysis and structural design. All calculation and analysis results are contained in the MHM Final Design Report which is part of the Vendor Information File 50100. Subsequent to the MHM supplier engineering analysis, there was a separate analyses for nuclear safety accident concerns that used the electronic input data files provided by FWEC/GEC-ESL and are contained in document SNF-6248

  19. Multi Canister Overpack (MCO) Handling Machine Independent Review of Seismic Structural Analysis

    Energy Technology Data Exchange (ETDEWEB)

    SWENSON, C.E.

    2000-09-22

    The following separate reports and correspondence pertains to the independent review of the seismic analysis. The original analysis was performed by GEC-Alsthom Engineering Systems Limited (GEC-ESL) under subcontract to Foster-Wheeler Environmental Corporation (FWEC) who was the prime integration contractor to the Spent Nuclear Fuel Project for the Multi-Canister Overpack (MCO) Handling Machine (MHM). The original analysis was performed to the Design Basis Earthquake (DBE) response spectra using 5% damping as required in specification, HNF-S-0468 for the 90% Design Report in June 1997. The independent review was performed by Fluor-Daniel (Irvine) under a separate task from their scope as Architect-Engineer of the Canister Storage Building (CSB) in 1997. The comments were issued in April 1998. Later in 1997, the response spectra of the Canister Storage Building (CSB) was revised according to a new soil-structure interaction analysis and accordingly revised the response spectra for the MHM and utilized 7% damping in accordance with American Society of Mechanical Engineers (ASME) NOG-1, ''Rules for Construction of Overhead and Gantry Cranes (Top Running Bridge, Multiple Girder).'' The analysis was re-performed to check critical areas but because manufacturing was underway, designs were not altered unless necessary. FWEC responded to SNF Project correspondence on the review comments in two separate letters enclosed. The dispositions were reviewed and accepted. Attached are supplier source surveillance reports on the procedures and process by the engineering group performing the analysis and structural design. All calculation and analysis results are contained in the MHM Final Design Report which is part of the Vendor Information File 50100. Subsequent to the MHM supplier engineering analysis, there was a separate analyses for nuclear safety accident concerns that used the electronic input data files provided by FWEC/GEC-ESL and are contained in

  20. Differences in Muscle Activity During Cable Resistance Training Are Influenced by Variations in Handle Types.

    Science.gov (United States)

    Rendos, Nicole K; Heredia Vargas, Héctor M; Alipio, Taislaine C; Regis, Rebeca C; Romero, Matthew A; Signorile, Joseph F

    2016-07-01

    Rendos, NK, Heredia Vargas, HM, Alipio, TC, Regis, RC, Romero, MA, and Signorile, JF. Differences in muscle activity during cable resistance training are influenced by variations in handle types. J Strength Cond Res 30(7): 2001-2009, 2016-There has been a recent resurgence in the use of cable machines for resistance training allowing movements that more effectively simulate daily activities and sports-specific movements. By necessity, these devices require a machine/human interface through some type of handle. Considerable data from material handling, industrial engineering, and exercise training studies indicate that handle qualities, especially size and shape, can significantly influence force production and muscular activity, particularly of the forearm muscles, which affect the critical link in activities that require object manipulation. The purpose for this study was to examine the influence of three different handle conditions: standard handle (StandH), ball handle with the cable between the index and middle fingers (BallIM), and ball handle with the cable between the middle and ring fingers (BallMR), on activity levels (rmsEMG) of the triceps brachii lateral and long heads (TriHLat, TriHLong), brachioradialis (BR), flexor carpi radialis (FCR), extensor carpi ulnaris, and extensor digitorum (ED) during eight repetitions of standing triceps pushdown performed from 90° to 0° elbow flexion at 1.5 s per contractile stage. Handle order was randomized. No significant differences were seen for triceps or BR rmsEMG across handle conditions; however, relative patterns of activation did vary for the forearm muscles by handle condition, with more coordinated activation levels for the FCR and ED during the ball handle conditions. In addition, the rmsEMG for the ED was significantly higher during the BallIM than any other condition and during the BallMR than the StandH. These results indicate that the use of ball handles with the cable passing between different fingers

  1. Readability Trends of Online Information by the American Academy of Otolaryngology-Head and Neck Surgery Foundation.

    Science.gov (United States)

    Wong, Kevin; Levi, Jessica R

    2017-01-01

    Objective Previous studies have shown that patient education materials published by the American Academy of Otolaryngology-Head and Neck Surgery Foundation may be too difficult for the average reader to understand. The purpose of this study was to determine if current educational materials show improvements in readability. Study Design Cross-sectional analysis. Setting The Patient Health Information section of the American Academy of Otolaryngology-Head and Neck Surgery Foundation website. Subjects and Methods All patient education articles were extracted in plain text. Webpage navigation, references, author information, appointment information, acknowledgments, and disclaimers were removed. Follow-up editing was also performed to remove paragraph breaks, colons, semicolons, numbers, percentages, and bullets. Readability grade was calculated with the Flesch-Kincaid Grade Level, Flesch Reading Ease, Gunning-Fog Index, Coleman-Liau Index, Automated Readability Index, and Simple Measure of Gobbledygook. Intra- and interobserver reliability were assessed. Results A total of 126 articles from 7 topics were analyzed. Readability levels across all 6 tools showed that the difficulty of patient education materials exceeded the abilities of an average American. As compared with previous studies, current educational materials by the American Academy of Otolaryngology-Head and Neck Surgery Foundation have shown a decrease in difficulty. Intra- and interobserver reliability were both excellent, with intraclass coefficients of 0.99 and 0.96, respectively. Conclusion Improvements in readability is an encouraging finding and one that is consistent with recent trends toward improved health literacy. Nevertheless, online patient educational material is still too difficult for the average reader. Revisions may be necessary for current materials to benefit a larger readership.

  2. Operating a pneumatic-mechanical flotation machine for coal-slurry flotation

    Energy Technology Data Exchange (ETDEWEB)

    Shmaenok, N M; Bedran, N G; Konstantinov, V K; Kochetkov, Yu I; Sysoev, V S

    1976-01-01

    The FPM-GMO-1.6 pneumatic-mechanical flotation machine is easy to operate and regulate and maintains a high throughput at a low energy consumption. The flotation process is stable, the quality of the concentrate and tailings satisfactory, and the selectivity of separation high. The machine cannot handle coal slurries at higher throughputs because the rate of froth removal is too low across the entire flotation front. Experience on the pneumatic-mechanical flotation machine at the ''Kolosnikovskaya'' Central Washery indicates that a similar machine should be developed for a throughput of 1000 m/sup 3//hr.

  3. Accuracy and readability of cardiovascular entries on Wikipedia: are they reliable learning resources for medical students?

    Science.gov (United States)

    Azer, Samy A; AlSwaidan, Nourah M; Alshwairikh, Lama A; AlShammari, Jumana M

    2015-10-06

    To evaluate accuracy of content and readability level of English Wikipedia articles on cardiovascular diseases, using quality and readability tools. Wikipedia was searched on the 6 October 2013 for articles on cardiovascular diseases. Using a modified DISCERN (DISCERN is an instrument widely used in assessing online resources), articles were independently scored by three assessors. The readability was calculated using Flesch-Kincaid Grade Level. The inter-rater agreement between evaluators was calculated using the Fleiss κ scale. This study was based on 47 English Wikipedia entries on cardiovascular diseases. The DISCERN scores had a median=33 (IQR=6). Four articles (8.5%) were of good quality (DISCERN score 40-50), 39 (83%) moderate (DISCERN 30-39) and 4 (8.5%) were poor (DISCERN 10-29). Although the entries covered the aetiology and the clinical picture, there were deficiencies in the pathophysiology of diseases, signs and symptoms, diagnostic approaches and treatment. The number of references varied from 1 to 127 references; 25.9±29.4 (mean±SD). Several problems were identified in the list of references and citations made in the articles. The readability of articles was 14.3±1.7 (mean±SD); consistent with the readability level for college students. In comparison, Harrison's Principles of Internal Medicine 18th edition had more tables, less references and no significant difference in number of graphs, images, illustrations or readability level. The overall agreement between the evaluators was good (Fleiss κ 0.718 (95% CI 0.57 to 0.83). The Wikipedia entries are not aimed at a medical audience and should not be used as a substitute to recommended medical resources. Course designers and students should be aware that Wikipedia entries on cardiovascular diseases lack accuracy, predominantly due to errors of omission. Further improvement of the Wikipedia content of cardiovascular entries would be needed before they could be considered a supplementary resource

  4. SIMULASI GROUP TECHNOLOGY SYSTEM UNTUK MEMINIMALKAN BIAYA MATERIAL HANDLING DENGAN METODE HEURISTIC

    Directory of Open Access Journals (Sweden)

    Much. Djunaidi

    2006-04-01

    Full Text Available Group Technology System merupakan metode pengaturan fasilitas produksi (machine groups yang dibutuhkan untuk memproses suatu part family tertentu ke dalam sel-sel manufaktur. Pengaturan tata letak di CV. Sonytex yang berdasarkan process layout mengakibatkan perusahaan menghadapi permasalahan berupa tingginya kebutuhan material handling. Salah satu kriteria kinerja dalam pembentukan sel manufaktur pada GTS adalah meminimasi total jarak material handling, sehingga dapat mengurangi biaya material handling dan meningkatkan produktivitas. Dalam penelitian ini digunakan tiga metode, yaitu Bond Energy Algorithm (BEA, Rank Order Clustering (ROC dan Rank Order Clustering 2 (ROC2. Hasil dari penelitian ini adalah dengan menerapkan group technology systems diperoleh total pengurangan jarak material handling sebesar 70 m dan penghematan biaya material handling sebesar Rp 1.534.978,-. Berdasarkan model simulasi, relayout dengan metode BEA meningkatkan jumlah produksi sebesar 1 unit produk/hari dan penurunan waktu tunggu sebesar 0,575 menit.

  5. Automatic refueling platform and CRD remote handling device for BWR plant

    International Nuclear Information System (INIS)

    Kato, Hiroaki; Takagi, Kaoru

    1978-01-01

    In BWR plants, machines for replacing fuel assemblies and control rod drives are usually operated directly by personnel. An automatic refueling platform and a CRD remote handling device aiming at radiation exposure reduction and handling perfectness are described, which are already used in BWR plants. Automation of the former is achieved in transporting fuel assemblies between a reactor pressure vessel and a fuel storage pool, shuffling fuel assemblies in a reactor core and moving fuel assemblies in a fuel storage pool. In the latter, replacement of CRDs is nearly all performed remotely. (Mori, K.)

  6. A New Approach for Handling of Micro Parts in Bulk Metal Forming

    DEFF Research Database (Denmark)

    Mahshid, Rasoul; Hansen, Hans Nørgaard; Arentoft, M.

    2012-01-01

    of production [1]. This can fulfill the demands for mass production and miniaturization in industries and academic communities. According to the recent studies, topics related to materials, process and simulation have been investigated intensively and well documented. Machines, forming tools and handling...... systems are critical elements to complete micro forming technology for transferring knowledge to industries and toward miniature manufacturing systems (micro factory) [2]. Since most metal forming processes are multi stage, making a new handling system with high reliability on accuracy and speed...... have been optimized or handling systems based on new concepts for gripping and releasing micro parts have been proposed. Making a handling system for micro parts made by sheet metals or foils is easier than those in bulk metal forming because parts are attached to the sheet during the forming process...

  7. Improvements in or relating to gripping means for handling nuclear reactor fuel assemblies

    International Nuclear Information System (INIS)

    Batjukov, V.I.; Vjugov, O.N.; Fadeev, A.I.; Shkhian, T.G.

    1980-01-01

    A gripping means for handling fuel assemblies, the heads of which are internally recessed to receive gripping jaws, forms part of a reactor refuelling machine and is telescopically accommodated within a manipulator tube of the machine. A through hole is provided to allow cooling medium to be passed through the fuel assemblies to remove afterheat when the gripping means is used to transfer assemblies from a reactor core to spent fuel storage sockets. (author)

  8. Trends in remote handling device development

    International Nuclear Information System (INIS)

    Raimondi, T.

    1991-01-01

    A brief review is given of studies on layouts and methods for handling some major components requiring remote maintenance in future fusion reactors: Neutral sources and beam lines, the blanket, divertor plates, armour tiles and vacuum pumps. Comparison is made to problems encountered in JET, methods and equipment used and development work done there. Areas requiring development and research are outlined. These include topics which are the subject of papers presented here, such as dynamic studies and control of transporters, improvements to the man-machine interface and hot cell equipment. A variety of other topics where effort is needed are also mentioned: Environmental tolerance of components and equipment, TV viewing and compensation of viewing difficulties with aids such as computer graphics and image processing, safety assessment, computer aids for remote manipulation, remote cutting and welding techniques, routine in-vessel inspection methods and selection of connectors and flanges for remote handling. (orig.)

  9. Third Molars on the Internet: A Guide for Assessing Information Quality and Readability.

    Science.gov (United States)

    Hanna, Kamal; Brennan, David; Sambrook, Paul; Armfield, Jason

    2015-10-06

    Directing patients suffering from third molars (TMs) problems to high-quality online information is not only medically important, but also could enable better engagement in shared decision making. This study aimed to develop a scale that measures the scientific information quality (SIQ) for online information concerning wisdom tooth problems and to conduct a quality evaluation for online TMs resources. In addition, the study evaluated whether a specific piece of readability software (Readability Studio Professional 2012) might be reliable in measuring information comprehension, and explored predictors for the SIQ Scale. A cross-sectional sample of websites was retrieved using certain keywords and phrases such as "impacted wisdom tooth problems" using 3 popular search engines. The retrieved websites (n=150) were filtered. The retained 50 websites were evaluated to assess their characteristics, usability, accessibility, trust, readability, SIQ, and their credibility using DISCERN and Health on the Net Code (HoNCode). Websites' mean scale scores varied significantly across website affiliation groups such as governmental, commercial, and treatment provider bodies. The SIQ Scale had a good internal consistency (alpha=.85) and was significantly correlated with DISCERN (r=.82, Psoftware estimates were associated with scientific information comprehensiveness measures.

  10. An analysis of the readability of patient information and consent forms used in research studies in anaesthesia in Australia and New Zealand.

    Science.gov (United States)

    Taylor, H E; Bramley, D E P

    2012-11-01

    The provision of written information is a component of the informed consent process for research participants. We conducted a readability analysis to test the hypothesis that the language used in patient information and consent forms in anaesthesia research in Australia and New Zealand does not meet the readability standards or expectations of the Good Clinical Practice Guidelines, the National Health and Medical Research Council in Australia and the Health Research Council of New Zealand. We calculated readability scores for 40 patient information and consent forms using the Simple Measure of Gobbledygook and Flesch-Kincaid formulas. The mean grade level of patient information and consent forms when using the Simple Measure of Gobbledygook and Flesch-Kincaid readability formulas was 12.9 (standard deviation of 0.8, 95% confidence interval 12.6 to 13.1) and 11.9 (standard deviation 1.1, 95% confidence interval 11.6 to 12.3), respectively. This exceeds the average literacy and comprehension of the general population in Australia and New Zealand. Complex language decreases readability and negatively impacts on the informed consent process. Care should be exercised when providing written information to research participants to ensure language and readability is appropriate for the audience.

  11. Automatic welding machine for piping

    International Nuclear Information System (INIS)

    Yoshida, Kazuhiro; Koyama, Takaichi; Iizuka, Tomio; Ito, Yoshitoshi; Takami, Katsumi.

    1978-01-01

    A remotely controlled automatic special welding machine for piping was developed. This machine is utilized for long distance pipe lines, chemical plants, thermal power generating plants and nuclear power plants effectively from the viewpoint of good quality control, reduction of labor and good controllability. The function of this welding machine is to inspect the shape and dimensions of edge preparation before welding work by the sense of touch, to detect the temperature of melt pool, inspect the bead form by the sense of touch, and check the welding state by ITV during welding work, and to grind the bead surface and inspect the weld metal by ultrasonic test automatically after welding work. The construction of this welding system, the main specification of the apparatus, the welding procedure in detail, the electrical source of this welding machine, the cooling system, the structure and handling of guide ring, the central control system and the operating characteristics are explained. The working procedure and the effect by using this welding machine, and the application to nuclear power plants and the other industrial field are outlined. The HIDIC 08 is used as the controlling computer. This welding machine is useful for welding SUS piping as well as carbon steel piping. (Nakai, Y.)

  12. Investigation and analysis the vibration of handles of chainsaw without cutting

    Directory of Open Access Journals (Sweden)

    M Feyzi

    2016-04-01

    Full Text Available Introduction: Nowadays most of the agricultural and industrial tasks are performed using different machines and almost any people are exposed to the vibration of these machines. Just as sound can be either music to the ear or irritating noise, human vibrations can either be pleasant or unpleasant. Whole-body vibration and hand-arm vibration are two main types of unpleasant vibration. The hand-arm transmitted vibration can cause complex vascular, neurological and musculoskeletal disorder, collectively named as hand-arm vibration syndrome. The chainsaw is a portable machine, powered by a two-stroke engine. This machine is used by tree surgeons to fell trees, remove branches, and other activities such as prune trees. The chainsaw exposes own operators to high level of hand-arm vibration which can lead to problems such as vibration white finger syndrome and Raynaud's phenomenon. White finger syndrome affects the nerves, blood vessels, muscles, and joints of the hand, wrist and arm. It is clear that before trying to control the vibrations, the level of vibrations should be identified. Therefore, an investigation on the vibration level of this machine is crucial. Materials and Methods: The Stihl-MS230 chainsaw was selected in this study. The size of this type of chainsaw is middle and it is equipped with anti-vibration system. According to the ISO-7505 standard, vibration must be measured at three speed level of engine. First at idling speed, second at nominal speed and third at 133% of the nominal speed or maximum speed of engine whichever is less (Racing. So 2800, 10000, and 13300 RPM Engine speed were selected. One of the employed accessories was ARMA ETI-TACHO tachometer which had been fabricated in Taiwan. The vibrations were measured and analyzed using the portable data acquisition system (Easy Viber. During the measurements, data acquisition system was powered by internal batteries. The vibrations were sensed by the piezoelectric accelerometer

  13. Evaluation of Quality and Readability of Health Information Websites Identified through India’s Major Search Engines

    Directory of Open Access Journals (Sweden)

    S. Raj

    2016-01-01

    Full Text Available Background. The available health information on websites should be reliable and accurate in order to make informed decisions by community. This study was done to assess the quality and readability of health information websites on World Wide Web in India. Methods. This cross-sectional study was carried out in June 2014. The key words “Health” and “Information” were used on search engines “Google” and “Yahoo.” Out of 50 websites (25 from each search engines, after exclusion, 32 websites were evaluated. LIDA tool was used to assess the quality whereas the readability was assessed using Flesch Reading Ease Score (FRES, Flesch-Kincaid Grade Level (FKGL, and SMOG. Results. Forty percent of websites (n=13 were sponsored by government. Health On the Net Code of Conduct (HONcode certification was present on 50% (n=16 of websites. The mean LIDA score (74.31 was average. Only 3 websites scored high on LIDA score. Only five had readability scores at recommended sixth-grade level. Conclusion. Most health information websites had average quality especially in terms of usability and reliability and were written at high readability levels. Efforts are needed to develop the health information websites which can help general population in informed decision making.

  14. Logic without unique readability - a study of semantic and syntactic ambiguity

    DEFF Research Database (Denmark)

    Bentzen, Martin Mose

    One of the main reasons for introducing a formal language is to remove ambiguity, the possibility of assigning several meanings to a linguistic expression. Typically, this is achieved through ensuring unique readability of formulas by using brackets (or another convention, such as Polish notation...... not hold true universally. Whereas e.g. scope ambiguities in natural languages have been studied extensively, ambiguous formal languages have not been the focus of in depth research. Here, we lift the assumption of unique readability by omitting the brackets from propositional logic, making it possible...... to formally distinguish between syntactic and semantic ambiguity. A valuation then amounts to a semantic disambiguation, and rather than a unique valuation (truth value), there is a set of valuations corresponding to ways a formula could have been constructed. We show what happens to familiar concepts...

  15. The use of physical model simulation to emulate an AGV material handling system

    International Nuclear Information System (INIS)

    Hurley, R.G.; Coffman, P.E.; Dixon, J.R.; Walacavage, J.G.

    1987-01-01

    This paper describes an application of physical modeling to the simulation of a prototype AGV (Automatic Guided Vehicle) material handling system. Physical modeling is the study of complex automated manufacturing and material handling systems through the use of small scale components controlled by mini and/or microcomputers. By modeling the mechanical operations of the proposed AGV material handling system, it was determined that control algorithms and AGV dispatch rules could be developed and evaluated. This paper presents a brief explanation of physical modeling as a simulation tool and addresses in detail the development of the control algorithm, dispatching rules, and a prototype physical model of a flexible machining system

  16. Readability Levels of the Reading Passages in the ITED: Final Report. Iowa Testing Programs Research Report. Number 6.

    Science.gov (United States)

    Forsyth, Robert

    The readability level of passages from three subtests of the Iowa Tests of Educational Development (ITED), Forms X-6 and Y-6, were compared with the readability level of passages selected from the Des Moines Resister, Reader's Digest, Time, Newsweek, Saturday Review, and 18 high school textbooks from the fields of social studies, science, and…

  17. Reply to "Further Issues in Determining the Readability of Self-Report Items: Comment on McHugh and Behar (2009)"

    Science.gov (United States)

    McHugh, R. Kathryn; Behar, Evelyn

    2012-01-01

    In his commentary on our previously published article "Readability of Self-Report Measures of Depression and Anxiety," J. Schinka (2012) argued for the importance of considering readability of patient materials and highlighted limitations of existing methodologies for this assessment. Schinka's commentary articulately described the weaknesses of…

  18. Readability of self-illuminated signs obscured by black fuel-fire smoke.

    Science.gov (United States)

    1980-07-01

    This study, using black fuel-fire generated smoke, is a partial replication of an earlier study using an inert white smoke as the obscuring agent in the study of the readability of smoke-obscured, self-illuminated emergency exit signs. : The results ...

  19. How well are health information websites displayed on mobile phones? Implications for the readability of health information.

    Science.gov (United States)

    Cheng, Christina; Dunn, Matthew

    2017-03-01

    Issue addressed More than 87% of Australians own a mobile phone with Internet access and 82% of phone owners use their smartphones to search for health information, indicating that mobile phones may be a powerful tool for building health literacy. Yet, online health information has been found to be above the reading ability of the general population. As reading on a smaller screen may further complicate the readability of information, this study aimed to examine how health information is displayed on mobile phones and its implications for readability. Methods Using a cross-sectional design with convenience sampling, a sample of 270 mobile webpages with information on 12 common health conditions was generated for analysis, they were categorised based on design and position of information display. Results The results showed that 71.48% of webpages were mobile-friendly but only 15.93% were mobile-friendly webpages designed in a way to optimise readability, with a paging format and queried information displayed for immediate viewing. Conclusion With inadequate evidence and lack of consensus on how webpage design can best promote reading and comprehension, it is difficult to draw a conclusion on the effect of current mobile health information presentation on readability. So what? Building mobile-responsive websites should be a priority for health information providers and policy-makers. Research efforts are urgently required to identify how best to enhance readability of mobile health information and fully capture the capabilities of mobile phones as a useful device to increase health literacy.

  20. The role of readability in effective health communication: an experiment using a Japanese health information text on chronic suppurative otitis media.

    Science.gov (United States)

    Sakai, Yukiko

    2013-09-01

    This study identifies the most significant readability factors and examines ways of improving and evaluating Japanese health information text in terms of ease of reading and understanding. Six different Japanese texts were prepared based on an original short text written by a medical doctor for a hospital web site intended for laypersons regarding chronic suppurative otitis media. Four were revised for single readability factor (syntax, vocabulary, or text structure) and two were modified in all three factors. Using a web-based survey, 270 high school students read one of the seven texts, including the original, completed two kinds of comprehension tests, and answered questions on their impressions of the text's readability. Significantly higher comprehension test scores were shown in the true or false test for a mixed text that presented important information first for better text structure. They were also found in the cloze test for a text using common vocabulary and a cohesive mixed text. Vocabulary could be a critical single readability factor when presumably combined with better text structure. Using multiple evaluation methods can help assess comprehensive readability. The findings on improvement and evaluation methods of readability can be applied to support effective health communication. © 2013 The authors. Health Information and Libraries Journal © 2013 Health Libraries Group Health Information and Libraries Journal.

  1. Remote handling needs of the Princeton Plasma Physics Laboratory

    International Nuclear Information System (INIS)

    Smiltnieks, V.

    1982-07-01

    This report is the result of a Task Force study commissioned by the Canadian Fusion Fuels Technology Project (CFFTP) to investigate the remote handling requirements at the Princeton Plasma Physics Laboratory (PPPL) and identify specific areas where CFFTP could offer a contractual or collaborative participation, drawing on the Canadian industrial expertise in remote handling technology. The Task Force reviewed four areas related to remote handling requirements; the TFTR facility as a whole, the service equipment required for remote maintenance, the more complex in-vessel components, and the tritium systems. Remote maintenance requirements both inside the vacuum vessel and around the periphery of the machine were identified as the principal areas where Canadian resources could effectively provide an input, initially in requirement definition, concept evaluation and feasibility design, and subsequently in detailed design and manufacture. Support requirements were identified in such areas as the mock-up facility and a variety of planning studies relating to reliability, availability, and staff training. Specific tasks are described which provide an important data base to the facility's remote handling requirements. Canadian involvement in the areas is suggested where expertise exists and support for the remote handling work is warranted. Reliability, maintenance operations, inspection strategy and decommissioning are suggested for study. Several specific components are singled out as needing development

  2. Readability of Spanish language online information for the initial treatment of burns.

    Science.gov (United States)

    Votta, Kaitlyn; Metivier, Meghan; Romo, Stephanie; Garrigan, Hannah; Drexler, Alana; Nodoushani, Ariana; Sheridan, Robert

    2018-06-01

    This study's aim is to identify the most popular online resources for burn treatment information available in the Spanish language, and to evaluate the readability of this information. The phrase "tratamiento de quemaduras" (burn treatment) was entered into search engines Google and Bing on 9/15/2014 and 9/13/2017. The top 12 Spanish web results on each site were identified and analyzed using Readability Studio Professional Edition v2012.1. The software generated a "mean grade reading level" for each article, or the grade of students that could be expected to understand the article's language. 21 distinct articles were identified at T1 and 17 at T2, with seven overlapping between T1 and T2. The average grade reading level of all the websites ranged from 7.8 to 13.8 at T1 (approximately 8th grade to sophomore year of college) and 7.8 to 12.2 at T2. No websites were within 1 standard deviation of the American Medical Association recommended 6th grade reading level. With readability showing little improvement during the past three years, providers should be aware of the complexity of online literature, and the potential complications this presents to patients. Additionally, burn centers should prioritize generating more accessible information for the Spanish speaking public. Copyright © 2017 Elsevier Ltd and ISBI. All rights reserved.

  3. Critical Analysis of the Quality, Readability, and Technical Aspects of Online Information Provided for Neck-Lifts.

    Science.gov (United States)

    Rayess, Hani; Zuliani, Giancarlo F; Gupta, Amar; Svider, Peter F; Folbe, Adam J; Eloy, Jean Anderson; Carron, Michael A

    2017-03-01

    The number of patients using the internet to obtain health information is growing. This material is unregulated and heterogeneous and can influence patient decisions. To compare the quality, readability, and technical aspects of online information about neck-lifts provided by private practice websites vs academic medical centers and reference sources. In this cross-sectional analysis conducted between November 2015 and January 2016, a Google search of the term neck-lift was performed, and the first 45 websites were evaluated. The websites were categorized as private practice vs other. Private websites (PWs) included sites created by private practice physicians. Other websites (OWs) were created by academic medical centers or reference sources. Quality, readability, and technical aspects of online websites related to neck-lifts. Quality was assessed using the DISCERN criteria and the Health on the Net principles (HONcode). Readability was assessed using 7 validated and widely used criteria. Consensus US reading grade level readability was provided by a website (readabilityformulas.com). Twelve technical aspects were evaluated based on criteria specified by medical website creators. Forty-five websites (8 OWs [18%] and 37 PWs [82%]) were analyzed. There was a significant difference in quality between OWs and PWs based on the DISCERN criteria and HONcode principles. The DISCERN overall mean (SD) scores were 2.3 (0.5) for OWs and 1.3 (0.3) for PWs (P analysis, the mean (SD) was 8.6 (1.8) (range, 5-11) for OW, and the mean (SD) was 5.8 (1.7) (range, 2-9) for PW. The mean (SD) readability consensus reading grade level scores were 11.7 (1.9) for OWs and 10.6 (1.9) for PWs. Of a total possible score of 12, the mean (SD) technical scores were 6.3 (1.8) (range, 4-9) for OWs and 6.4 (1.5) (range, 3-9) for PWs. Compared with PWs, OWs had a significantly higher quality score based on both the DISCERN criteria and HONcode principles. The mean readability for OWs and PWs was

  4. Readability Levels of Health-Based Websites: From Content to Comprehension

    Science.gov (United States)

    Schutten, Mary; McFarland, Allison

    2009-01-01

    Three of the national health education standards include decision-making, accessing information and analyzing influences. WebQuests are a popular inquiry-oriented method used by secondary teachers to help students achieve these content standards. While WebQuests support higher level thinking skills, the readability level of the information on the…

  5. Spanish Readability Formulas for Elementary-Level Texts: A Validation Study.

    Science.gov (United States)

    Parker, Richard I.; Hasbrouck, Jan E.; Weaver, Laurie

    2001-01-01

    Uses two formulas developed for Spanish language text to analyze 9 stories that were read by 36 Spanish-speaking second graders with limited English proficiency. Finds that the Spanish readability formulas only weakly predicted student performance, indicating the need to pursue broader, qualitative indices of difficulty for Spanish text. (SG)

  6. CANDU 9 fuelling machine carriage

    Energy Technology Data Exchange (ETDEWEB)

    Ullrich, D J; Slavik, J F [Atomic Energy of Canada Ltd., Saskatoon, SK (Canada)

    1997-12-31

    Continuous, on-power refuelling is a key feature of all CANDU reactor designs and is essential to maintaining high station capacity factors. The concept of a fuelling machine carriage can be traced to the early CANDU designs, such as the Douglas Point Nuclear Generating Station. In the CANDU 9 480NU unit, the combination of a mobile carriage and a proven fuelling machine head design comprises an effective means of transporting fuel between the reactor and the fuel transfer ports. It is a suitable alternative to the fuelling machine bridge system that has been utilized in the CANDU 6 reactor units. The CANDU 9 480NU fuel handling system successfully combines features that meet the project requirements with respect to fuelling performance, functionality, seismic qualification and the use of proven components. The design incorporates improvements based on experience and applicable current technologies. (author). 4 figs.

  7. CANDU 9 fuelling machine carriage

    International Nuclear Information System (INIS)

    Ullrich, D.J.; Slavik, J.F.

    1996-01-01

    Continuous, on-power refuelling is a key feature of all CANDU reactor designs and is essential to maintaining high station capacity factors. The concept of a fuelling machine carriage can be traced to the early CANDU designs, such as the Douglas Point Nuclear Generating Station. In the CANDU 9 480NU unit, the combination of a mobile carriage and a proven fuelling machine head design comprises an effective means of transporting fuel between the reactor and the fuel transfer ports. It is a suitable alternative to the fuelling machine bridge system that has been utilized in the CANDU 6 reactor units. The CANDU 9 480NU fuel handling system successfully combines features that meet the project requirements with respect to fuelling performance, functionality, seismic qualification and the use of proven components. The design incorporates improvements based on experience and applicable current technologies. (author). 4 figs

  8. Quality and readability of websites for patient information on tonsillectomy and sleep apnea.

    Science.gov (United States)

    Chi, Ethan; Jabbour, Noel; Aaronson, Nicole Leigh

    2017-07-01

    Tonsillectomy is a common treatment for obstructive sleep apnea (OSA). The Internet allows patients direct access to medical information. Since information on the Internet is largely unregulated, quality and readability are variable. This study evaluates the quality and readability of the most likely visited websites presenting information on sleep apnea and tonsillectomy. The three most popular search engines (Google, Bing, Yahoo) were queried with the phrase "sleep apnea AND tonsillectomy." The DISCERN instrument was used to assess quality of information. Readability was evaluated using the Flesch-Kincaid Reading Grade Level (FKGL) and Flesch Reading Ease Score (FRES). Out of the maximum of 80, the average DISCERN quality score for the websites was 55.1 (SD- 12.3, Median- 60.5). The mean score for FRES was 42.3 (SD- 15.9, Median- 45.5), which falls in the range defined as difficult. No website was above the optimal score of 65. The mean score for the FKGL was US grade-level of 10.7 (SD- 1.6, Median- 11.6). Only 4(27%) websites were in the optimal range of 6-8. There was very weak correlation between FRES and DISCERN (r = 0.07) and FKGL and DISCERN (r = 0.21). Tonsillectomy is one of the most common surgeries in the US. However, the internet information readily available to patients varies in quality. Additionally, much of the information is above the recommended grade level for comprehension by the public. By being aware of what information patients are reading online, physicians can better explain treatments and address misunderstandings. Physicians may consider using similar methods to test the readability for their own resources for patient education. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Readability of patient discharge instructions with and without the use of electronically available disease-specific templates.

    Science.gov (United States)

    Mueller, Stephanie K; Giannelli, Kyla; Boxer, Robert; Schnipper, Jeffrey L

    2015-07-01

    Low health literacy is common, leading to patient vulnerability during hospital discharge, when patients rely on written health instructions. We aimed to examine the impact of the use of electronic, patient-friendly, templated discharge instructions on the readability of discharge instructions provided to patients at discharge. We performed a retrospective cohort study of 233 patients discharged from a large tertiary care hospital to their homes following the implementation of a web-based "discharge module," which included the optional use of diagnosis-specific templated discharge instructions. We compared the readability of discharge instructions, as measured by the Flesch Reading Ease Level test (FREL, on a 0-100 scale, with higher scores indicating greater readability) and the Flesch-Kincaid Grade Level test (FKGL, measured in grade levels), between discharges that used templated instructions (with or without modification) versus discharges that used clinician-generated instructions (with or without available templated instructions for the specific discharge diagnosis). Templated discharge instructions were provided to patients in 45% of discharges. Of the 55% of patients that received clinician-generated discharge instructions, the majority (78.1%) had no available templated instruction for the specific discharge diagnosis. Templated discharge instructions had higher FREL scores (71 vs. 57, P readability (a higher FREL score and a lower FKGL score) than the use of clinician-generated discharge instructions. The main reason for clinicians to create discharge instructions was the lack of available templates for the patient's specific discharge diagnosis. Use of electronically available templated discharge instructions may be a viable option to improve the readability of written material provided to patients at discharge, although the library of available templates requires expansion. © The Author 2015. Published by Oxford University Press on behalf of the

  10. Which, When, and How: Hierarchical Clustering with Human–Machine Cooperation

    Directory of Open Access Journals (Sweden)

    Huanyang Zheng

    2016-12-01

    Full Text Available Human–Machine Cooperations (HMCs can balance the advantages and disadvantages of human computation (accurate but costly and machine computation (cheap but inaccurate. This paper studies HMCs in agglomerative hierarchical clusterings, where the machine can ask the human some questions. The human will return the answers to the machine, and the machine will use these answers to correct errors in its current clustering results. We are interested in the machine’s strategy on handling the question operations, in terms of three problems: (1 Which question should the machine ask? (2 When should the machine ask the question (early or late? (3 How does the machine adjust the clustering result, if the machine’s mistake is found by the human? Based on the insights of these problems, an efficient algorithm is proposed with five implementation variations. Experiments on image clusterings show that the proposed algorithm can improve the clustering accuracy with few question operations.

  11. Investigation of Effect of Machine Layout on Productivity and Utilization Level: What If Simulation Approach

    Directory of Open Access Journals (Sweden)

    Islam Faisal Bourini

    2018-03-01

    Full Text Available Designing and selecting the material handling system is a vital factor for any production line, and as result for the whole manufacturing system. Poor design and unsuitable handling equipment may increase the risk of having bottlenecks, longer production time and as a result the higher total production cost. One of the useful and effective tools are using “what if” simulation techniques. However, this technique needs effective simulation software. The main objective for this research is to simulate different types of handling system using what if scenario. To achieve the objective of the research, Delmia Quest software has been used to simulate two different systems: manual system and conveyers system for the same production line and analyses the differences in terms of utilization and production rate. The results obtained have been analysed and appraised to induce the bottleneck locations, productivity and utilizations of the machines and material handling systems used in the design system. Finally, the best model have been developed to increase the productivity, utilizations of the machines, material handling systems and to minimize the bottleneck locations.

  12. An experimental study on the readability of digital images in the furcal bone defects

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Hyung Wuk; Hwang, Eui Hwan; Lee, Sang Rae [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    2003-06-15

    To evaluate and compare the efficacy of digital radiographic images in the detection of bone loss at the bifurcation area of the mandibular first molar with traditional film-based periapical radiographs. One dried human mandible with minimal periodontal bone loss around the first molar was selected and an artificial alveolar bone defect at the bifurcation area was serially prepared over 18 steps. Images were taken using a direct CCD-based system and with F-speed periapical films. The images were evaluated by seven interpreters (3 radiologists, 3 periodontologists, and 1 general dentist) using a 5-point confidence rating scale. The readability of both periapical radiographs and digital image increased as the size of the artificial lesion and exposure time increased (p<0.05). Periapical radiographs offered greater readability of smaller bone defects than digital images, and the coefficient of variation of mean score between periapical radiographs and digital images showed a significant difference. The experimental results indicate that a significant difference in the coefficient of variation of mean score exists between periapical radiographs and digital images, and that traditional film-based periapical images offer greater readability of smaller bone defects than digital images can presently offer.

  13. An experimental study on the readability of digital images in the furcal bone defects

    International Nuclear Information System (INIS)

    Kang, Hyung Wuk; Hwang, Eui Hwan; Lee, Sang Rae

    2003-01-01

    To evaluate and compare the efficacy of digital radiographic images in the detection of bone loss at the bifurcation area of the mandibular first molar with traditional film-based periapical radiographs. One dried human mandible with minimal periodontal bone loss around the first molar was selected and an artificial alveolar bone defect at the bifurcation area was serially prepared over 18 steps. Images were taken using a direct CCD-based system and with F-speed periapical films. The images were evaluated by seven interpreters (3 radiologists, 3 periodontologists, and 1 general dentist) using a 5-point confidence rating scale. The readability of both periapical radiographs and digital image increased as the size of the artificial lesion and exposure time increased (p<0.05). Periapical radiographs offered greater readability of smaller bone defects than digital images, and the coefficient of variation of mean score between periapical radiographs and digital images showed a significant difference. The experimental results indicate that a significant difference in the coefficient of variation of mean score exists between periapical radiographs and digital images, and that traditional film-based periapical images offer greater readability of smaller bone defects than digital images can presently offer.

  14. Readability and quality assessment of internet-based patient education materials related to laryngeal cancer.

    Science.gov (United States)

    Narwani, Vishal; Nalamada, Keerthana; Lee, Michael; Kothari, Prasad; Lakhani, Raj

    2016-04-01

    Patients are increasingly using the internet to access health-related information. The purpose of this study was to assess the readability and quality of laryngeal cancer-related websites. Patient education materials were identified by performing an internet search using 3 search engines. Readability was assessed using Flesch Reading Ease Score (FRES), Flesch-Kincaid Grade Level (FKGL), and Gunning Fog Index (GFI). The DISCERN instrument was utilized to assess quality of health information. A total of 54 websites were included in the analysis. The mean readability scores were as follows: FRES, 48.2 (95% confidence interval [CI] = 44.8-51.6); FKGL, 10.9 (95% CI = 10.3-11.5); and GFI, 13.8 (95% CI = 11.3-16.3). These scores suggest that, on average, online information about patients with laryngeal cancer is written at an advanced level. The mean DISCERN score was 49.8 (95% CI = 45.4-54.2), suggesting that online information is of variable quality. Our study suggests much of the laryngeal cancer information available online is of suboptimal quality and written at a level too difficult for the average adult to read comfortably. © 2015 Wiley Periodicals, Inc.

  15. Readability of Written Materials for CKD Patients: A Systematic Review.

    Science.gov (United States)

    Morony, Suzanne; Flynn, Michaela; McCaffery, Kirsten J; Jansen, Jesse; Webster, Angela C

    2015-06-01

    The "average" patient has a literacy level of US grade 8 (age 13-14 years), but this may be lower for people with chronic kidney disease (CKD). Current guidelines suggest that patient education materials should be pitched at a literacy level of around 5th grade (age 10-11 years). This study aims to evaluate the readability of written materials targeted at patients with CKD. Systematic review. Patient information materials aimed at adults with CKD and written in English. Patient education materials designed to be printed and read, sourced from practices in Australia and online at all known websites run by relevant international CKD organizations during March 2014. Quantitative analysis of readability using Lexile Analyzer and Flesch-Kincaid tools. We analyzed 80 materials. Both Lexile Analyzer and Flesch-Kincaid analyses suggested that most materials required a minimum of grade 9 (age 14-15 years) schooling to read them. Only 5% of materials were pitched at the recommended level (grade 5). Readability formulas have inherent limitations and do not account for visual information. We did not consider other media through which patients with CKD may access information. Although the study covered materials from the United States, United Kingdom, and Australia, all non-Internet materials were sourced locally, and it is possible that some international paper-based materials were missed. Generalizability may be limited due to exclusion of non-English materials. These findings suggest that patient information materials aimed at patients with CKD are pitched above the average patient's literacy level. This issue is compounded by cognitive decline in patients with CKD, who may have lower literacy than the average patient. It suggests that information providers need to consider their audience more carefully when preparing patient information materials, including user testing with a low-literacy patient population. Copyright © 2015 National Kidney Foundation, Inc. Published by

  16. The Readability and Complexity of District-Provided School-Choice Information

    Science.gov (United States)

    Stein, Marc L.; Nagro, Sarah

    2015-01-01

    Public school choice has become a common feature in American school districts. Any potential benefits that could be derived from these policies depend heavily on the ability of parents and students to make informed and educated decisions about their school options. We examined the readability and complexity of school-choice guides across a sample…

  17. [Systematic Readability Analysis of Medical Texts on Websites of German University Clinics for General and Abdominal Surgery].

    Science.gov (United States)

    Esfahani, B Janghorban; Faron, A; Roth, K S; Grimminger, P P; Luers, J C

    2016-12-01

    Background: Besides the function as one of the main contact points, websites of hospitals serve as medical information portals. As medical information texts should be understood by any patients independent of the literacy skills and educational level, online texts should have an appropriate structure to ease understandability. Materials and Methods: Patient information texts on websites of clinics for general surgery at German university hospitals (n = 36) were systematically analysed. For 9 different surgical topics representative medical information texts were extracted from each website. Using common readability tools and 5 different readability indices the texts were analysed concerning their readability and structure. The analysis was furthermore stratified in relation to geographical regions in Germany. Results: For the definite analysis the texts of 196 internet websites could be used. On average the texts consisted of 25 sentences and 368 words. The reading analysis tools congruously showed that all texts showed a rather low readability demanding a high literacy level from the readers. Conclusion: Patient information texts on German university hospital websites are difficult to understand for most patients. To fulfill the ambition of informing the general population in an adequate way about medical issues, a revision of most medical texts on websites of German surgical hospitals is recommended. Georg Thieme Verlag KG Stuttgart · New York.

  18. Automatic tea service machine with instantaneous cooling unit; Shunkan reikyaku kiko tosai jido kyuchaki

    Energy Technology Data Exchange (ETDEWEB)

    Sato, T.; Nishiyama, A. [Fuji Denki Reiki Co. Ltd., Tokyo (Japan)

    1999-08-10

    The market of automatic tea service machines demands sanitation, reduction in time required for pouring tea, feeding the material, cleaning the inside of the machine, the maintenance and service of the machine, and excellent design. To meet these demands, Fuji Electric has changed the former configuration and components for functions and has developed a new series of instantaneous automatic tea service machines based on a new concept. This paper outlines the advantages of the instantaneous cooling tank and improvements in handling. (author)

  19. Automation of a universal machine

    International Nuclear Information System (INIS)

    Rodriguez S, J.

    1997-01-01

    The development of the hardware and software of a control system for a servo-hydraulic machine is presented. The universal machine is an Instron, model 1331, used to make mechanical tests. The software includes the acquisition of data from the measurements, processing and graphic presentation of the results in the assay of the 'tension' type. The control is based on a PPI (Programmable Peripheral Interface) 8255, in which the different states of the machine are set. The control functions of the machine are: a) Start of an assay, b) Pause in the assay, c) End of the assay, d) Choice of the control mode of the machine, that they could be in load, stroke or strain modes. For the data acquisition, a commercial card, National Products, model DAS-16, plugged in a slot of a Pc was used. Three transducers provide the analog signals, a cell of load, a LVDT and a extensometer. All the data are digitalized and handled in order to get the results in the appropriate working units. A stress-strain graph is obtained in the screen of the Pc for a tension test for a specific material. The points of maximum stress, rupture stress and the yield stress of the material under test are shown. (Author)

  20. Sample-Based Extreme Learning Machine with Missing Data

    Directory of Open Access Journals (Sweden)

    Hang Gao

    2015-01-01

    Full Text Available Extreme learning machine (ELM has been extensively studied in machine learning community during the last few decades due to its high efficiency and the unification of classification, regression, and so forth. Though bearing such merits, existing ELM algorithms cannot efficiently handle the issue of missing data, which is relatively common in practical applications. The problem of missing data is commonly handled by imputation (i.e., replacing missing values with substituted values according to available information. However, imputation methods are not always effective. In this paper, we propose a sample-based learning framework to address this issue. Based on this framework, we develop two sample-based ELM algorithms for classification and regression, respectively. Comprehensive experiments have been conducted in synthetic data sets, UCI benchmark data sets, and a real world fingerprint image data set. As indicated, without introducing extra computational complexity, the proposed algorithms do more accurate and stable learning than other state-of-the-art ones, especially in the case of higher missing ratio.

  1. Health literacy and contraception: a readability evaluation of contraceptive instructions for condoms, spermicides and emergency contraception in the USA.

    Science.gov (United States)

    El-Ibiary, Shareen Y; Youmans, Sharon L

    2007-03-01

    To assess readability of over-the-counter (OTC) contraceptive product instructions currently available, compare the results with previous studies from a decade ago, and review the implications for health care providers, in particular pharmacists counseling on OTC contraceptives. A sample of contraceptive instructions was submitted to a readability analysis using four standard readability formulas. Products included condoms, spermicides, and emergency contraception instruction pamphlets. Reading grade levels for condoms ranged from 6th to 12th grade. The average reading levels for the spermicides were 9th-10th grade and for the emergency contraceptives 10th-12th grade. These results were consistent with those of similar studies performed a decade ago. Consumers need to have at least a high school reading level in order to comprehend current product instructions. Very little has changed in the past decade regarding readability of OTC contraceptive patient instructions, despite calls to simplify written instructions. Healthcare providers, in particular pharmacists, must be aware of these disparities to enhance patient education and advocate for simpler reading materials.

  2. Research on intelligent machine self-perception method based on LSTM

    Science.gov (United States)

    Wang, Qiang; Cheng, Tao

    2018-05-01

    In this paper, we use the advantages of LSTM in feature extraction and processing high-dimensional and complex nonlinear data, and apply it to the autonomous perception of intelligent machines. Compared with the traditional multi-layer neural network, this model has memory, can handle time series information of any length. Since the multi-physical domain signals of processing machines have a certain timing relationship, and there is a contextual relationship between states and states, using this deep learning method to realize the self-perception of intelligent processing machines has strong versatility and adaptability. The experiment results show that the method proposed in this paper can obviously improve the sensing accuracy under various working conditions of the intelligent machine, and also shows that the algorithm can well support the intelligent processing machine to realize self-perception.

  3. Readability and quality assessment of websites related to microtia and aural atresia.

    Science.gov (United States)

    Alamoudi, Uthman; Hong, Paul

    2015-02-01

    Many parents and children utilize the Internet for health-related information, but the quality of these websites can vary. The objective of this study was to assess the quality and readability of microtia and aural atresia related websites. The search engine Google was queried with the terms 'microtia' and 'aural atresia.' The first 30 results were evaluated, and those websites containing original information written in English were reviewed. Quality of content was assessed with the DISCERN instrument, and readability was assessed with the Flesch-Kincaid Reading Grade Level (FKGL) and the Flesch Reading Ease Score (FRES) tests. Each website was also reviewed for ownership and the date of last update. Sixteen microtia and 14 aural atresia websites were included for full review. The mean DISCERN score for microtia websites was 54.4 (SD=8.3), and for aural atresia websites it was 47.6 (SD=10.7), which indicates 'good' and 'fair' quality of content, respectively. Readability assessments showed an average reading level requiring a grade 10 education on FKGL, and only one microtia (6.3%) and one aural atresia (7.1%) websites were deemed to be at 'reasonable' reading level on FRES. High-quality websites that are considered easily comprehensible to the general public were lacking. Since parents and children may use websites when making treatment decisions, physicians should be aware of the quality of health information pertaining to their area of expertise available on the Internet. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  4. About machine-readable travel documents

    International Nuclear Information System (INIS)

    Vaudenay, S; Vuagnoux, M

    2007-01-01

    Passports are documents that help immigration officers to identify people. In order to strongly authenticate their data and to automatically identify people, they are now equipped with RFID chips. These contain private information, biometrics, and a digital signature by issuing authorities. Although they substantially increase security at the border controls, they also come with new security and privacy issues. In this paper, we survey existing protocols and their weaknesses

  5. About machine-readable travel documents

    Energy Technology Data Exchange (ETDEWEB)

    Vaudenay, S; Vuagnoux, M [EPFL, Lausanne (Switzerland)

    2007-07-15

    Passports are documents that help immigration officers to identify people. In order to strongly authenticate their data and to automatically identify people, they are now equipped with RFID chips. These contain private information, biometrics, and a digital signature by issuing authorities. Although they substantially increase security at the border controls, they also come with new security and privacy issues. In this paper, we survey existing protocols and their weaknesses.

  6. DICOM involving XML path-tag

    Science.gov (United States)

    Zeng, Qiang; Yao, Zhihong; Liu, Lei

    2011-03-01

    Digital Imaging and Communications in Medicine (DICOM) is a standard for handling, storing, printing, and transmitting information in medical imaging. XML (Extensible Markup Language) is a set of rules for encoding documents in machine-readable form which has become more and more popular. The combination of these two is very necessary and promising. Using XML tags instead of numeric labels in DICOM files will effectively increase the readability and enhance the clear hierarchical structure of DICOM files. However, due to the fact that the XML tags rely heavily on the orders of the tags, the strong data dependency has a lot of influence on the flexibility of inserting and exchanging data. In order to improve the extensibility and sharing of DICOM files, this paper introduces XML Path-Tag to DICOM. When a DICOM file is converted to XML format, adding simple Path-Tag into the DICOM file in place of complex tags will keep the flexibility of a DICOM file while inserting data elements and give full play to the advantages of the structure and readability of an XML file. Our method can solve the weak readability problem of DICOM files and the tedious work of inserting data into an XML file. In addition, we set up a conversion engine that can transform among traditional DICOM files, XML-DCM and XML-DCM files involving XML Path-Tag efficiently.

  7. Development and operating performance of the refuelling machine of the Fugen

    International Nuclear Information System (INIS)

    Kaneko, Jun; Kasai, Yoshimitsu; Takeshita, Norito; Ohta, Takeo

    1985-01-01

    In the advanced thermal reactor ''Fugen'' power station, with the refuelling machine the fuel replacement during operation is made through the reactor bottom. Its design was started in 1967 and up to 1975 various tests were conducted. Fugen's refuelling machine has thus been used from the initial fuel loading in 1978 and handled so far about 1300 fuel assemblies in seven times of the refuelling. In the stage of Fugen operation there occurred failure of the grab drive due to crud, etc. At present, with such troubles all eliminated, the refuelling machine is in steady operation with proper maintenance. The results with Fugen's refuelling machine are reflected in the development of the refuelling machine for the demonstration ATR. (Mori, K.)

  8. Development on the ex-vessel transfer machine for Monju, (1)

    International Nuclear Information System (INIS)

    Inoue, Takashi; Kinuta, Kenji; Tomita, Takaaki

    1980-01-01

    As for the fast breeder reactors being developed as the national project, the construction of the prototype reactor ''Monju'' is started in 1980 based on the results of development of the experimental reactor ''Joyo''. In the fuel-handling facility, the development of which is promoted by Fuji Electric Co., Ltd., the development of the fuel transfer machines which take out and charge the fuel for the reactors and carry out the transport between fuel storage facilities is important subject. In this paper, the outline of the development of a fuel transfer machine is described, centering around the handling of fuel in sodium and the removal of the heat of spent fuel. ''Monju'' with 300 MW electric output is being developed for the purposes of putting fast breeder reactors in practical use, increasing plant power output, improving the rate of operation, and securing the safety. Plutonium is used as the fuel, and liquid metallic sodium is used as the coolant in fast breeder reactors, accordingly the fuel must be handled safely in gas-tight, shielded vessels while it is cooled, and securely in sodium and sodium cover gas by remote operation. Gripper, gripper-driving mechanism, coffin, movable block, door valves, cooling system and carriage compose the fuel transfer machine, and these are described. The main results of development and the tests for the development, such as the trial manufacture of gripper and decay heat removal test, are reported. (Kako, I.)

  9. Third Molars on the Internet: A Guide for Assessing Information Quality and Readability

    Science.gov (United States)

    Brennan, David; Sambrook, Paul; Armfield, Jason

    2015-01-01

    Background Directing patients suffering from third molars (TMs) problems to high-quality online information is not only medically important, but also could enable better engagement in shared decision making. Objectives This study aimed to develop a scale that measures the scientific information quality (SIQ) for online information concerning wisdom tooth problems and to conduct a quality evaluation for online TMs resources. In addition, the study evaluated whether a specific piece of readability software (Readability Studio Professional 2012) might be reliable in measuring information comprehension, and explored predictors for the SIQ Scale. Methods A cross-sectional sample of websites was retrieved using certain keywords and phrases such as “impacted wisdom tooth problems” using 3 popular search engines. The retrieved websites (n=150) were filtered. The retained 50 websites were evaluated to assess their characteristics, usability, accessibility, trust, readability, SIQ, and their credibility using DISCERN and Health on the Net Code (HoNCode). Results Websites’ mean scale scores varied significantly across website affiliation groups such as governmental, commercial, and treatment provider bodies. The SIQ Scale had a good internal consistency (alpha=.85) and was significantly correlated with DISCERN (r=.82, Preadability grade (10.3, SD 1.9) was above the recommended level, and was significantly correlated with the Scientific Information Comprehension Scale (r=.45. PReadability Studio software estimates were associated with scientific information comprehensiveness measures. PMID:26443470

  10. Assessing the Readability of Geoscience Textbooks, Laboratory Manuals, and Supplemental Materials

    Science.gov (United States)

    Hippensteel, Scott P.

    2015-01-01

    Reading materials used in undergraduate science classes have not received the same attention in the literature as those used in secondary schools. Additionally, reports critical of college textbooks and their prose are common. To assess both problems and determine the readability of assignments and texts used by geoscience faculty at the…

  11. Readability of Igbo Language Textbook in Use in Nigerian Secondary Schools

    Science.gov (United States)

    Eze, Nneka Justina

    2015-01-01

    This study assessed the readability of Igbo language textbook in use in Nigerian secondary schools. Five Igbo Language textbook were evaluated. The study employed an evaluation research design. The study was conducted in South Eastern Geopolitical zone of Nigeria which is predominantly the Igbo tribe of Nigeria. Four hundred secondary school…

  12. Sodium removal from the grapples of the fuel handling facility of Joyo

    Energy Technology Data Exchange (ETDEWEB)

    Mukaibo, R; Matsuno, Y; Sato, I; Yoneda, Y; Sato, H [O-arai Engineering Centre, PNC, Ibaraki-ken, Tokio (Japan)

    1978-08-01

    Sodium removal from the grapples of the fuel handling facility of 'JOYO' is done in alcohol. The operations of the cleaning facility started as the functional tests of the fuel handling facility began. Since then, criticality test and low power tests had been done and during this period, sodium removal from the grapples, after a certain amount of time in use, were done. In order to lessen the time for the cleaning process for the grapples of the machines inside the containment vessel, demineralized water concentration in the alcohol was gained to as much as 10% and good results were obtained. On the other hand, there were very small amounts of sodium on the grapples of the machine used outside the containment vessel and direct charging of demineralized water into the cleaning pot was done experimentally, also with good results. In this report, the sodium removal experience of the grapples before power up tests and some remarks on the improvements of the facility for the future are presented. (author)

  13. Machine throughput improvement achieved using innovative control technique

    International Nuclear Information System (INIS)

    Sharma, V.; Acharya, S.; Mittal, K.C.

    2012-01-01

    In any type of fully or semi automatic machine the control systems plays an important role. The control system on the one hand has to consider the human psychology, intelligence requirement for an operator, and attention needed from him. On the other hand the complexity of the control has also to be understood well before designing a control system that can be handled comfortably and safely by the operator. As far as the user experience/comfort is concerned the design of control system GUI is vital. Considering these two aspects related to the user of the machine it is evident that the control system design is very important because it is has to accommodate the human behaviour and skill sets required/available as well as the capability of the machine under the control of the control system. An intelligently designed control system can enhance the productivity of the machine. (author)

  14. Quality and readability of online patient information regarding sclerotherapy for venous malformations.

    Science.gov (United States)

    Pass, Jonathan H; Patel, Amani H; Stuart, Sam; Barnacle, Alex M; Patel, Premal A

    2018-05-01

    Patients often use the internet as a source of information about their condition and treatments. However, this information is unregulated and varies in quality. To evaluate the readability and quality of online information for pediatric and adult patients and caregivers regarding sclerotherapy for venous malformations. "Venous malformation sclerotherapy" was entered into Google, and results were reviewed until 20 sites that satisfied predefined inclusion criteria were identified. Scientific and non-patient-focused web pages were excluded. Readability was assessed using the Flesch Reading Ease Score and American Medical Association reading difficulty recommendations and quality was assessed using Journal of the American Medical Association standards and assessing if the site displayed HONcode (Health on the Net Code) certification. Assessment of the breadth of relevant information was made using a predefined checklist. Forty-nine search engine results were reviewed before 20 sites were identified for analysis. Average Flesch Reading Ease Score was 44 (range: 24.2-70.1), representing a "fairly difficult" reading level. None of the sites had a Flesch Reading Ease Score meeting the American Medical Association recommendation of 80-90. Only one site met all four Journal of the American Medical Association quality criteria (average: 2.1). None of the sites displayed a HONcode seal. The information most frequently found was: sclerotherapy is performed by radiologists, multiple treatments may be needed and surgery is an alternative treatment. Online information regarding sclerotherapy for venous malformations is heterogeneous in quality and breadth of information, and does not meet readability recommendations for patient information. Radiologists should be aware of and account for this when meeting patients.

  15. The Evaluation of High School Geography 9 and High School Geography 11 Text Books with Some Formulas of Readability

    Science.gov (United States)

    Gecit, Yilmaz

    2010-01-01

    The purpose of this study is to evaluate readability of 9th and 11th grade geography text-books currently used in schools. As known, one of the most fundamental features in a text-book is the readability of the text by students. In addition, it is also very important that the fluency and suitability of books match age level. In this study, the…

  16. Expansion mechanisms for indigenously developed horizontal honing machines (Paper No. 06)

    International Nuclear Information System (INIS)

    Murthy, G.S.K.; Devarajan, N.

    1987-02-01

    Coolant channel components for nuclear reactors require scratch free and smooth interior surfaces in addition to control on size. This calls for finish machining by honing process. At the time when these were required to be made, there were no manufacturers in India who were making honing machines especially of horizontal type. In order to meet this requirement, Central Workshops of Bhabha Atomic Research Centre developed and manufactured two horizontal honing machines which can handle tubes upto three metres in length. One of the machines has been so made to accommodate jobs upto six metres in length. Stone expansion mechanisms used in these machines were of automatic hydraulic type combined with a mechanical expansion device. Details of these mechanisms have been discussed in this paper. (author). 3 figs

  17. The readability of expert reports for non-scientist report-users: reports of forensic comparison of glass.

    Science.gov (United States)

    Howes, Loene M; Kirkbride, K Paul; Kelty, Sally F; Julian, Roberta; Kemp, Nenagh

    2014-03-01

    Scientific language contains features that may impede understanding for non-scientists. Forensic scientists' written reports are read by police, lawyers, and judges, and thus assessment of readability is warranted. Past studies of readability differed in background theory and approach, but analysed one or more of: content and sequence; language; and format. Using a holistic approach, we assessed the readability of expert reports (n=78) of forensic glass comparison from 7 Australian jurisdictions. Two main audiences for reports were relevant: police and the courts. Reports for police were presented either as a completed form or as a brief legal-style report. Reports for court were less brief and used either legal or scientific styles, with content and formatting features supporting these distinctions. Some jurisdictions prepared a single report to satisfy both the courts and police. In general, item list, analytical techniques, results, notes on interpretation, and conclusions were included in reports of all types. However, some reports omitted analytical techniques, and results and conclusions were sometimes combined. According to Flesch Reading Ease, language was difficult, with a Flesch-Kincaid grade level of university undergraduate. Sentences were long and contained undefined specialist terms. Information content per clause (lexical density), was typically high, as for other scientific texts. Uncertainty was expressed differently by jurisdiction. Reports from most jurisdictions were cluttered in appearance, with single-line spacing, narrow margins, and gridlines in tables. Simple suggestions, based on theory and past research, are provided to assist scientists to enhance the readability of expert reports for non-scientists. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. Readability, complexity, and suitability of online resources for mastectomy and lumpectomy.

    Science.gov (United States)

    Tran, Bao Ngoc N; Singh, Mansher; Singhal, Dhruv; Rudd, Rima; Lee, Bernard T

    2017-05-15

    Nearly half of American adults have low or marginal health literacy. This negatively affects patients' participation, decision-making, satisfaction, and overall outcomes especially when there is a mismatch between information provided and the skills of the intended audience. Recommendations that patient information be written below the sixth grade level have been made for over three decades. This study compares online resources for mastectomy versus lumpectomy using expanded metrics including readability level, complexity, and density of data and overall suitability for public consumption. The 10 highest ranked Web sites for mastectomy and lumpectomy were identified using the largest Internet engine (Google). Each Web site was assessed for readability (Simple Measure of Gobbledygook), complexity (PMOSE/iKIRSCH), and suitability (Suitability Assessment of Materials). Scores were analyzed by each Web site and overall. Readability analysis showed a significant reading grade level difference between mastectomy and lumpectomy online information (15.4 and 13.9, P = 0.04, respectively). Complexity analysis via PMOSE/iKIRSCH revealed a mean score of 6.5 for mastectomy materials corresponding to "low" complexity and eighth to 12 th grade education. Lumpectomy literature had a lower PMOSE/iKIRSCH score of 5.8 corresponding to a "very low" complexity and fourth to eighth grade education (P = 0.05). Suitability assessment showed mean values of 41% and 46% (P = 0.83) labeled as the lowest level of "adequacy" for mastectomy and lumpectomy materials, respectively. Inter-rater reliability was high for both complexity and suitability analysis. Online resources for the surgical treatment of breast cancer are above the recommended reading grade level. The suitability level is barely adequate indicating a need for revision. Online resources for mastectomy have a higher reading grade level than do materials for lumpectomy and tend to be more complex. Copyright © 2017 Elsevier

  19. Readability of written medicine information materials in Arabic language: expert and consumer evaluation.

    Science.gov (United States)

    Al Aqeel, Sinaa; Abanmy, Norah; Aldayel, Abeer; Al-Khalifa, Hend; Al-Yahya, Maha; Diab, Mona

    2018-02-27

    Written Medicine Information (WMI) is one of the sources that patients use to obtain information concerning medicine. This paper aims to assess the readability of two types of WMIs in Arabic language based on vocabulary use and sentence structure using a panel of experts and consumers. This is a descriptive study. Two different types of materials, including the online text from King Abdullah Bin Abdulaziz Arabic Health Encyclopaedia (KAAHE) and medication leaflets submitted by the manufacturers to the Saudi Food and Drug Authority (SFDA) were evaluated. We selected a group of sentences from each WMI. The readability was assessed by experts (n = 5) and consumers (n = 5). The sentence readability of each measured using a specific criteria and rated as 1 = easy, 2 = intermediate, or 3 = difficult. A total of 4476 sentences (SFDA 2231; KAHEE 2245) extracted from websites or patient information leaflets on 50 medications and evaluated. The majority of the vocabulary and sentence structure was considered easy by both expert (SFDA: 68%; KAAHE: 76%) and consumer (SFDA: 76%; KAAHE: 84%) groups. The sentences with difficult or intermediate vocabulary and sentence structure are derived primarily from the precautions and side effects sections. The SFDA and KAAHE WMIs are easy to read and understand as judged by our study sample. However; there is room for improvement, especially in sections related to the side effects and precautions.

  20. Prostate Cancer Information Available in Health-Care Provider Offices: An Analysis of Content, Readability, and Cultural Sensitivity.

    Science.gov (United States)

    Choi, Seul Ki; Seel, Jessica S; Yelton, Brooks; Steck, Susan E; McCormick, Douglas P; Payne, Johnny; Minter, Anthony; Deutchki, Elizabeth K; Hébert, James R; Friedman, Daniela B

    2018-07-01

    Prostate cancer (PrCA) is the most common cancer affecting men in the United States, and African American men have the highest incidence among men in the United States. Little is known about the PrCA-related educational materials being provided to patients in health-care settings. Content, readability, and cultural sensitivity of materials available in providers' practices in South Carolina were examined. A total of 44 educational materials about PrCA and associated sexual dysfunction was collected from 16 general and specialty practices. The content of the materials was coded, and cultural sensitivity was assessed using the Cultural Sensitivity Assessment Tool. Flesch Reading Ease, Flesch-Kincaid Grade Level, and the Simple Measure of Gobbledygook were used to assess readability. Communication with health-care providers (52.3%), side effects of PrCA treatment (40.9%), sexual dysfunction and its treatment (38.6%), and treatment options (34.1%) were frequently presented. All materials had acceptable cultural sensitivity scores; however, 2.3% and 15.9% of materials demonstrated unacceptable cultural sensitivity regarding format and visual messages, respectively. Readability of the materials varied. More than half of the materials were written above a high-school reading level. PrCA-related materials available in health-care practices may not meet patients' needs regarding content, cultural sensitivity, and readability. A wide range of educational materials that address various aspects of PrCA, including treatment options and side effects, should be presented in plain language and be culturally sensitive.

  1. Universal machine ''Shtrek'' and the tractor-lifter with pneumatic-equipment control. [Auxiliary multipurpose materials handling equipment

    Energy Technology Data Exchange (ETDEWEB)

    Bal' bert, B M; Borumenskiy, V A; Lishenko, A P; Mitchenko, G A

    1982-01-01

    The machine ''Shtrek'' is described. It makes it possible to mechanize over 20 auxiliary operations: loading-unloading operations: extraction of old and deformed timbering; dissmantling of obstructions; erection of different types of timbering; making and restoring of drainage channels; laying and straightening of a drift and its leveling; assembly and disassembly of pipelines and mine equipment, etc. Depending on the type of operation, the machine has the corresponding suspended equipment. The elementary variant has a limited area of application at mines of the central region of the Dunbass. Currently a pneumatic variant of the machine ''Shtrek'' has been developed. The electric motor and the starter of the pumping equipment of the machine have been replaced by a pneumatic motor and pneumatically controlled valve KTM-50. In this case there was significant reduction in the weight of the pumping equipment and in its overall dimensions; the electric drive of the hydraulic distributors for controlling the mechanisms were replaced by simpler pneumatic ones; the logical circuit of the control system was constructed on the USEPPA elements. A specialized tractor-lifter designed for moving suspended loads is described for auxiliary operations in the near-face zone of the preparatory drifts. The machine also lifts and lowers the boom, rotates the boom by 270/sup 0/ and additionally lifts and lowers the weight-lifting hook.

  2. Textbook Readability and Student Performance in Online Introductory Corporate Finance Classes

    Science.gov (United States)

    Peng, Chien-Chih

    2015-01-01

    This paper examines whether the choice of a more readable textbook can improve student performance in online introductory corporate finance classes. The ordinary least squares regression model is employed to analyze a sample of 206 students during the period from 2008 to 2012. The results of this study show that the student's age, student's major,…

  3. An analysis of the readability characteristics of oral health information literature available to the public in Tasmania, Australia.

    Science.gov (United States)

    Barnett, Tony; Hoang, Ha; Furlan, Ashlea

    2016-03-17

    The effectiveness of print-based health promotion materials is dependent on their readability. This study aimed to assess the characteristics of print-based oral health information literature publically available in Tasmania, Australia. Oral health education brochures were collected from 11 dental clinics across Tasmania and assessed for structure and format, content and readability. Reading level was calculated using three widely-used measures: Flesch-Kincaid Grade Level (FKGL), Flesch Reading Ease, and Simple Measure of Gobbledygook (SMOG) reading grade level. The FKGL of the 67 brochures sampled ranged from grade 3 to 13. The grade level for government health department brochures (n = 14) ranged from grade 4 to 11 (5.6 ± 1.8). Reading levels for materials produced by commercial sources (n = 22) ranged from 3 to 13 (8.3 ± 2.1), those from professional associations (n = 22) ranged from grade 7 to 11 (8.9 ± 0.9) and brochures produced by other sources (n = 9) ranged from 5 to 10 (7.6 ± 1.5). The SMOG test was positively correlated with the FKGL (rs = 0.92, p readability characteristics differed. Many brochures required a reading skill level higher than that suited to a large proportion of the Tasmanian population. Readability and other characteristics of oral health education materials should be assessed to ensure their suitability for use with patients, especially those suspected of having low literacy skills.

  4. Reconstructing Readability: Recent Developments and Recommendations in the Analysis of Text Difficulty

    Science.gov (United States)

    Benjamin, Rebekah George

    2012-01-01

    Largely due to technological advances, methods for analyzing readability have increased significantly in recent years. While past researchers designed hundreds of formulas to estimate the difficulty of texts for readers, controversy has surrounded their use for decades, with criticism stemming largely from their application in creating new texts…

  5. Moved range monitor of a refueling machine

    International Nuclear Information System (INIS)

    Nakajima, Masaaki; Sakanaka, Tadao; Kayano, Hiroyuki.

    1976-01-01

    Purpose: To incorporate light receiving and emitting elements in a face monitor to thereby increase accuracy and reliability to facilitate handling in the refueling of a BWR power plant. Constitution: In the present invention, a refueling machine and a face monitoring light receiving and emitting elements are analogously coupled whereby the face monitoring light receiving and emitting elements may be moved so as to be analogous to a route along which the refueling machine has moved. A shielding plate is positioned in the middle of the light receiving and emitting elements, and the shielding plate is machined so as to be outside of action. The range of action of the refueling machine may be monitored depending on the light receiving state of the light receiving element. Since the present invention utilizes the permeating light as described above, it is possible to detect positions more accurately than the mechanical switch. In addition, the detection section is of the non-contact system and the light receiving element comprises a hot cell, and therefore the service life is extended and the reliability is high. (Nakamura, S.)

  6. Phase Space Prediction of Chaotic Time Series with Nu-Support Vector Machine Regression

    International Nuclear Information System (INIS)

    Ye Meiying; Wang Xiaodong

    2005-01-01

    A new class of support vector machine, nu-support vector machine, is discussed which can handle both classification and regression. We focus on nu-support vector machine regression and use it for phase space prediction of chaotic time series. The effectiveness of the method is demonstrated by applying it to the Henon map. This study also compares nu-support vector machine with back propagation (BP) networks in order to better evaluate the performance of the proposed methods. The experimental results show that the nu-support vector machine regression obtains lower root mean squared error than the BP networks and provides an accurate chaotic time series prediction. These results can be attributable to the fact that nu-support vector machine implements the structural risk minimization principle and this leads to better generalization than the BP networks.

  7. Image Classification, Deep Learning and Convolutional Neural Networks : A Comparative Study of Machine Learning Frameworks

    OpenAIRE

    Airola, Rasmus; Hager, Kristoffer

    2017-01-01

    The use of machine learning and specifically neural networks is a growing trend in software development, and has grown immensely in the last couple of years in the light of an increasing need to handle big data and large information flows. Machine learning has a broad area of application, such as human-computer interaction, predicting stock prices, real-time translation, and self driving vehicles. Large companies such as Microsoft and Google have already implemented machine learning in some o...

  8. Factors Affecting the Behavior of Engineering Students toward Safety Practices in the Machine Shop

    Directory of Open Access Journals (Sweden)

    Jessie Kristian M. Neria

    2015-08-01

    Full Text Available This study aimed to determine the factors that affect the behavior of engineering student toward safety practices in the machine shop. Descriptive type of research was utilized in the study. Results showed that most of the engineering students clearly understand the signage shown in the machine shop. Students are aware that they should not leave the machines unattended. Most of the engineering students handle and use the machine properly. The respondents have an average extent of safety practices in the machine shop which means that they are applying safety practices in their every activity in machine shop. There is strong relationship between the safety practices and the factors affecting behavior in terms of signage, reminder of teacher and rules and regulation.

  9. Research Translation Strategies to Improve the Readability of Workplace Health Promotion Resources

    Science.gov (United States)

    Wallace, Alison; Joss, Nerida

    2016-01-01

    Without deliberate and resourced translation, research evidence is unlikely to inform policy and practice. This paper describes the processes and practical solutions used to translate evaluation research findings to improve the readability of print materials in a large scale worksite health programme. It is argued that a knowledge brokering and…

  10. Readability of sports medicine-related patient education materials from the American Academy of Orthopaedic Surgeons and the American Orthopaedic Society for Sports Medicine.

    Science.gov (United States)

    Ganta, Abhishek; Yi, Paul H; Hussein, Khalil; Frank, Rachel M

    2014-04-01

    Although studies have revealed high readability levels of orthopedic patient education materials, no study has evaluated sports medicine-related patient education materials. We conducted a study to assess the readability of sports medicine-related patient education materials from the American Academy of Orthopaedic Surgeons (AAOS) and the American Orthopaedic Society for Sports Medicine (AOSSM). All sports medicine patient education articles available online in 2012 from the AAOS and the AOSSM, including the Stop Sports Injuries Campaign (STOP), were identified, and their readability was assessed with the Flesch-Kinkaid (FK) readability test. Mean overall FK grade level of the 170 articles reviewed (104 from AAOS, 36 from AOSSM, 30 from STOP) was 10.2. Mean FK levels for the 3 sources were 9.5 (AAOS), 11.0 (AOSSM), and 11.5 (STOP) (P = .16). Fifteen (8.8%) of the 170 articles had a readability level at or below eighth grade (average reading level of US adults); only 2 (1.2%) of the 170 articles were at or below the recommended sixth-grade level. The majority of sports medicine-related patient education materials from AAOS and AOSSM had reading levels higher than recommended, indicating that the majority of the patient population may find it difficult to comprehend these articles.

  11. Field handling conditions of raw milk sold in vending machines: experimental evaluation of the behaviour of Listeria monocytogenes, Escherichia coli O157:H7, Salmonella Typhimurium and Campylobacter jejuni

    Directory of Open Access Journals (Sweden)

    Renato G. Zanoni

    2012-01-01

    Full Text Available The direct sale by farmers of raw milk for human consumption has been allowed in Italy since 2004. The aim of this study was to evaluate the behaviour of selected foodborne pathogens in raw milk sold in vending machines, in field handling conditions, and during shelf-life from production to consumption. Temperature of storage of raw milk in 33 farms authorized to produce and sell raw milk were investigated from farm to vending machine delivery, together with consumer habits in one province of the Emilia-Romagna region of northern Italy. Failure to maintain appropriate low temperatures during shelf-life was recorded and 43% of consumers did not boil milk before consumption. Listeria monocytogenes, Escherichia coli O157:H7, Salmonella Typhimurium and Campylobacter jejuni strains were inoculated into raw milk samples, and the best (4°C as established by law and worst temperature storage conditions detected (variable temperature were simulated. Boiling tests were performed for each pathogen considered at high and low levels of contamination. Results showed an increase in L. monocytogenes in milk stored at 4°C and at variable temperatures recorded in shelf-life monitoring, an increase in E. coli O157:H7 and S. Typhimurium at variable temperatures but not at 4°C, and a decrease in C. jejuni in all storage conditions. Boiling milk is effective in making it safe for consumers. This study provides evidence that appropriate handling of raw milk, maintaining low temperatures, together with consumer education concerning boiling raw milk before consumption are key factors in preventing foodborne infections linked to raw milk consumption, and helps assess the risk of foodborne infection linked to raw milk consumption.

  12. Banknotes and unattended cash transactions

    Science.gov (United States)

    Bernardini, Ronald R.

    2000-04-01

    There is a 64 billion dollar annual unattended cash transaction business in the US with 10 to 20 million daily transactions. Even small problems with the machine readability of banknotes can quickly become a major problem to the machine manufacturer and consumer. Traditional note designs incorporate overt security features for visual validation by the public. Many of these features such as fine line engraving, microprinting and watermarks are unsuitable as machine readable features in low cost note acceptors. Current machine readable features, mostly covert, were designed and implemented with the central banks in mind. These features are only usable by the banks large, high speed currency sorting and validation equipment. New note designs should consider and provide for low cost not acceptors, implementing features developed for inexpensive sensing technologies. Machine readable features are only as good as their consistency. Quality of security features as well as that of the overall printing process must be maintained to ensure reliable and secure operation of note readers. Variations in printing and of the components used to make the note are one of the major causes of poor performance in low cost note acceptors. The involvement of machine manufacturers in new currency designs will aid note producers in the design of a note that is machine friendly, helping to secure the acceptance of the note by the public as well as acting asa deterrent to fraud.

  13. Readability and Content Assessment of Informed Consent Forms for Medical Procedures in Croatia.

    Science.gov (United States)

    Vučemilo, Luka; Borovečki, Ana

    2015-01-01

    High quality of informed consent form is essential for adequate information transfer between physicians and patients. Current status of medical procedure consent forms in clinical practice in Croatia specifically in terms of the readability and the content is unknown. The aim of this study was to assess the readability and the content of informed consent forms for diagnostic and therapeutic procedures used with patients in Croatia. 52 informed consent forms from six Croatian hospitals on the secondary and tertiary health-care level were tested for reading difficulty using Simple Measure of Gobbledygook (SMOG) formula adjusted for Croatian language and for qualitative analysis of the content. The averaged SMOG grade of analyzed informed consent forms was 13.25 (SD 1.59, range 10-19). Content analysis revealed that informed consent forms included description of risks in 96% of the cases, benefits in 81%, description of procedures in 78%, alternatives in 52%, risks and benefits of alternatives in 17% and risks and benefits of not receiving treatment or undergoing procedures in 13%. Readability of evaluated informed consent forms is not appropriate for the general population in Croatia. The content of the forms failed to include in high proportion of the cases description of alternatives, risks and benefits of alternatives, as well as risks and benefits of not receiving treatments or undergoing procedures. Data obtained from this research could help in development and improvement of informed consent forms in Croatia especially now when Croatian hospitals are undergoing the process of accreditation.

  14. Readability and Content Assessment of Informed Consent Forms for Medical Procedures in Croatia

    Science.gov (United States)

    Vučemilo, Luka; Borovečki, Ana

    2015-01-01

    Background High quality of informed consent form is essential for adequate information transfer between physicians and patients. Current status of medical procedure consent forms in clinical practice in Croatia specifically in terms of the readability and the content is unknown. The aim of this study was to assess the readability and the content of informed consent forms for diagnostic and therapeutic procedures used with patients in Croatia. Methods 52 informed consent forms from six Croatian hospitals on the secondary and tertiary health-care level were tested for reading difficulty using Simple Measure of Gobbledygook (SMOG) formula adjusted for Croatian language and for qualitative analysis of the content. Results The averaged SMOG grade of analyzed informed consent forms was 13.25 (SD 1.59, range 10–19). Content analysis revealed that informed consent forms included description of risks in 96% of the cases, benefits in 81%, description of procedures in 78%, alternatives in 52%, risks and benefits of alternatives in 17% and risks and benefits of not receiving treatment or undergoing procedures in 13%. Conclusions Readability of evaluated informed consent forms is not appropriate for the general population in Croatia. The content of the forms failed to include in high proportion of the cases description of alternatives, risks and benefits of alternatives, as well as risks and benefits of not receiving treatments or undergoing procedures. Data obtained from this research could help in development and improvement of informed consent forms in Croatia especially now when Croatian hospitals are undergoing the process of accreditation. PMID:26376183

  15. Radioactivity, shielding, radiation damage, and remote handling

    International Nuclear Information System (INIS)

    Wilson, M.T.

    1975-01-01

    Proton beams of a few hundred million electron volts of energy are capable of inducing hundreds of curies of activity per microampere of beam intensity into the materials they intercept. This adds a new dimension to the parameters that must be considered when designing and operating a high-intensity accelerator facility. Large investments must be made in shielding. The shielding itself may become activated and require special considerations as to its composition, location, and method of handling. Equipment must be designed to withstand large radiation dosages. Items such as vacuum seals, water tubing, and electrical insulation must be fabricated from radiation-resistant materials. Methods of maintaining and replacing equipment are required that limit the radiation dosages to workers.The high-intensity facilities of LAMPF, SIN, and TRIUMF and the high-energy facility of FERMILAB have each evolved a philosophy of radiation handling that matches their particular machine and physical plant layouts. Special tooling, commercial manipulator systems, remote viewing, and other techniques of the hot cell and fission reactor realms are finding application within accelerator facilities. (U.S.)

  16. Where humans meet machines innovative solutions for knotty natural-language problems

    CERN Document Server

    Markowitz, Judith

    2013-01-01

    Where Humans Meet Machines: Innovative Solutions for Knotty Natural-Language Problems brings humans and machines closer together by showing how linguistic complexities that confound the speech systems of today can be handled effectively by sophisticated natural-language technology. Some of the most vexing natural-language problems that are addressed in this book entail   recognizing and processing idiomatic expressions, understanding metaphors, matching an anaphor correctly with its antecedent, performing word-sense disambiguation, and handling out-of-vocabulary words and phrases. This fourteen-chapter anthology consists of contributions from industry scientists and from academicians working at major universities in North America and Europe. They include researchers who have played a central role in DARPA-funded programs and developers who craft real-world solutions for corporations. These contributing authors analyze the role of natural language technology in the global marketplace; they explore the need f...

  17. Readability of consumer health information on the internet: a comparison of U.S. government-funded and commercially funded websites.

    Science.gov (United States)

    Risoldi Cochrane, Zara; Gregory, Philip; Wilson, Amy

    2012-01-01

    The Internet has become an extremely prevalent means of communicating health information to consumers. Guidelines for selecting reliable health information websites give preference to U.S. government sites over commercially funded sites. However, these websites are not useful to consumers unless they are able to read and understand them. The authors' objective was to compare the readability of Internet health information intended for consumers found on U.S. government-funded websites versus that found on commercially funded websites. Consumer health websites were identified through a systematic Internet search. Webpages for 10 common health topics were extracted from each website. Readability of webpages was determined by 3 validated measures: Flesch Reading Ease, Flesch-Kincaid Reading Level, and SMOG Formula. Mean readability of government-funded and commercially funded websites was compared using the Mann-Whitney U test. Commercially funded websites were significantly more difficult to read as measured by Flesch Reading Ease (49.7 vs. 55.6 for government-funded sites, p = .002) and Flesch-Kincaid Reading Level (10.1 vs. 9.3, p = .012). There was no significant difference according to SMOG Formula (12.8 vs. 13.2, p = .150). The overall readability of Internet health information intended for consumers was poor. Efforts should be made to ensure that health information communicated via the Internet is easy for consumers to read and understand.

  18. Readability of Educational Materials to Support Parent Sexual Communication With Their Children and Adolescents.

    Science.gov (United States)

    Ballonoff Suleiman, Ahna; Lin, Jessica S; Constantine, Norman A

    2016-05-01

    Sexual communication is a principal means of transmitting sexual values, expectations, and knowledge from parents to their children and adolescents. Many parents seek information and guidance to support talking with their children about sex and sexuality. Parent education materials can deliver this guidance but must use appropriate readability levels to facilitate comprehension and motivation. This study appraised the readability of educational materials to support parent sexual communication with their children. Fifty brochures, pamphlets, and booklets were analyzed using the Flesch-Kincaid, Gunning Fog, and Simple Measure of Gobbledygook (SMOG) index methods. Mean readability grade-level scores were 8.3 (range = 4.5-12.8), 9.7 (range = 5.5-14.9), and 10.1 (range = 6.7-13.9), respectively. Informed by National Institutes of Health-recommended 6th to 7th grade levels and American Medical Association-recommended 5th to 6th grade levels, percentages falling at or below the 7.0 grade level were calculated as 38%, 12%, and 2% and those falling at or below the 6.0 grade level were calculated as 12%, 2%, and 0% based on the Flesch-Kincaid, Gunning Fog, and SMOG methods, respectively. These analyses indicate that the majority of educational materials available online to support parents' communication with their children about sex and sexuality do not meet the needs of many or most parents. Efforts to improve the accessibility of these materials are warranted.

  19. Aligning Theme and Information Structure to Improve the Readability of Technical Writing

    Science.gov (United States)

    Moore, N. A. J.

    2006-01-01

    The readability of technical writing, and technical manuals in particular, especially for second language readers, can be noticeably improved by pairing Theme with Given and Rheme with New. This allows for faster processing of text and easier access to the "method of development" of the text. Typical Theme-Rheme patterns are described, and the…

  20. Tritium decontamination of machine components and walls

    International Nuclear Information System (INIS)

    Hircq, B.; Wong, K.Y.; Jalbert, R.A.; Shmayda, W.T.

    1991-01-01

    Tritium decontamination techniques for machine components and their application at tritium handling facilities are reviewed. These include commonly used methods such as vacuuming, purging, thermal desorption and isotopic exchange as well as less common methods such as chemical/electrochemical etching, plasma discharge cleaning, and destructive methods. Problems associated with tritium contamination of walls and use of protective coatings are reviewed. Tritium decontamination considerations at fusion facilities are discussed

  1. Availability and Readability of Online Patient Education Materials Regarding Regional Anesthesia Techniques for Perioperative Pain Management.

    Science.gov (United States)

    Kumar, Gunjan; Howard, Steven K; Kou, Alex; Kim, T Edward; Butwick, Alexander J; Mariano, Edward R

    2017-10-01

    Patient education materials (PEM) should be written at a sixth-grade reading level or lower. We evaluated the availability and readability of online PEM related to regional anesthesia and compared the readability and content of online PEM produced by fellowship and nonfellowship institutions. With IRB exemption, we constructed a cohort of online regional anesthesia PEM by searching Websites from North American academic medical centers supporting a regional anesthesiology and acute pain medicine fellowships and used a standardized Internet search engine protocol to identify additional nonfellowship Websites with regional anesthesia PEM based on relevant keywords. Readability metrics were calculated from PEM using the TextStat 0.1.4 textual analysis package for Python 2.7 and compared between institutions with and without a fellowship program. The presence of specific descriptive PEM elements related to regional anesthesia was also compared between groups. PEM from 17 fellowship and 15 nonfellowship institutions were included in analyses. The mean (SD) Flesch-Kincaid Grade Level for PEM from the fellowship group was 13.8 (2.9) vs 10.8 (2.0) for the nonfellowship group (p = 0.002). We observed no other differences in readability metrics between fellowship and nonfellowship institutions. Fellowship-based PEM less commonly included descriptions of the following risks: local anesthetic systemic toxicity (p = 0.033) and injury due to an insensate extremity (p = 0.003). Available online PEM related to regional anesthesia are well above the recommended reading level. Further, fellowship-based PEM posted are at a higher reading level than PEM posted by nonfellowship institutions and are more likely to omit certain risk descriptions. 2016 American Academy of Pain Medicine. This work is written by US Government employees and is in the public domain in the US.

  2. Beauty and the Beast - on the readability of object-oriented example programs

    DEFF Research Database (Denmark)

    Börstler, Jürgen; Caspersen, Michael E.; Nordström, Marie

    2016-01-01

    Some solutions to a programming problem are more beautiful, elegant, and simple than others and thus more understandable for students. But why is it so, and can we quantify the notion of understandability of programs? We review desirable properties of program examples from a cognitive and a measu...... and exemplify a readability measure for software. An application of this measure to a set of object-oriented textbook examples shows encouraging results which we hope will ignite further research in this area.......Some solutions to a programming problem are more beautiful, elegant, and simple than others and thus more understandable for students. But why is it so, and can we quantify the notion of understandability of programs? We review desirable properties of program examples from a cognitive...... and a measurement point of view. It can be argued that some cognitive aspects of example programs are captured by common software measures, but we argue that they are not sucient to capture the most important aspects of understandability. A key aspect of understandability is readability. The authors propose...

  3. Structured Memory for Neural Turing Machines

    OpenAIRE

    Zhang, Wei; Yu, Yang; Zhou, Bowen

    2015-01-01

    Neural Turing Machines (NTM) contain memory component that simulates "working memory" in the brain to store and retrieve information to ease simple algorithms learning. So far, only linearly organized memory is proposed, and during experiments, we observed that the model does not always converge, and overfits easily when handling certain tasks. We think memory component is key to some faulty behaviors of NTM, and better organization of memory component could help fight those problems. In this...

  4. A Practical Method to Increase the Frequency Readability for Vibration Signals

    Directory of Open Access Journals (Sweden)

    Jean Loius Ntakpe

    2016-10-01

    Full Text Available Damage detection and nondestructive evaluation of mechanical and civil engineering structures are nowadays very important to assess the integrity and ensure the reliability of structures. Thus, frequency evaluation becomes a crucial issue, since this modal parameter is mainly used in structural integrity assessment. The herein presented study highligts the possibility of increasing the frequency readability by involving a simple and cost-effective method.

  5. Design characteristics of pantograph type in vessel fuel handling system in SFR

    International Nuclear Information System (INIS)

    Kim, S. H.; Koo, G. H.

    2012-01-01

    The pantograph type in vessel fuel handling system in a sodium cooled fast reactor (SFR), which requires installation space for the slot in the upper internal structure attached under the rotating plug, is composed of an in vessel transfer machine (IVTM), a single rotating plug, in vessel storage, and a fuel transfer port (FTP). The pantograph type IVTM can exchange fuel assemblies through a slot, the design requirement of which should be essentially considered in the design of the in vessel fuel handling system. In addition, the spent fuel assemblies temporarily stored in the in vessel storage of the reactor vessel are removed to the outside of the reactor vessel through the FTP. The fuel transfer basket is then provided in the FTP, and a fuel transfer is performed by using it. In this study, the design characteristics for a pantograph type in vessel fuel handling system are reviewed, and the preconceptual designs are studied

  6. Design characteristics of pantograph type in vessel fuel handling system in SFR

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. H.; Koo, G. H. [KAERI, Daejeon (Korea, Republic of)

    2012-10-15

    The pantograph type in vessel fuel handling system in a sodium cooled fast reactor (SFR), which requires installation space for the slot in the upper internal structure attached under the rotating plug, is composed of an in vessel transfer machine (IVTM), a single rotating plug, in vessel storage, and a fuel transfer port (FTP). The pantograph type IVTM can exchange fuel assemblies through a slot, the design requirement of which should be essentially considered in the design of the in vessel fuel handling system. In addition, the spent fuel assemblies temporarily stored in the in vessel storage of the reactor vessel are removed to the outside of the reactor vessel through the FTP. The fuel transfer basket is then provided in the FTP, and a fuel transfer is performed by using it. In this study, the design characteristics for a pantograph type in vessel fuel handling system are reviewed, and the preconceptual designs are studied.

  7. Designing and Evaluating Patient Education Pamphlets based on Readability Indexes and Comparison with Literacy Levels of Society

    Directory of Open Access Journals (Sweden)

    Mahdieh Arian

    2016-07-01

    Full Text Available Background: Hundreds of patient education materials i.e. pamphlets are annually published in healthcare systems following their design, correction, and revision. Aim: to design and evaluate patient education pamphlets based on readability indexes and their comparison with literacy level in society. Method: The average literacy level among 500 patients admitted to two training hospitals in Bojnurd (northeastern Iran was determined in 2014-2015. Afterwards, all patient education pamphlets in both hospitals (n=69 were collected and their readability level was determined. After that, all the pamphlets were re-designed according to the given standards and in line with literacy level in society. The SPSS software (Version 20 was also used to analyze the data. Results: The average level of literacy among 500 patients in both hospitals in the present study was 6.72±4.34 which was placed in grades six and seven in terms of the guide to readability indexes. In line with McLaughlin’s SMOG Readability Formula, the bulk of pamphlets (91.3% were at college level before corrections and revisions based on the given standards, but 23.2% were at a level lower than grade seven following corrections and revisions. Implications for Practice: Evaluation of patient education pamphlets plays an important role in promoting self-care among patients. Due to the novelty of the present study in Iran, the results of this study can contribute to patient education researchers in order to identify the strengths and weaknesses of patient education materials i.e. pamphlets based on scientific indices as well as their revisions and re-developments.

  8. Simplified zygomatic arch radiographic technique to overcome the drawback of jug handle view

    Directory of Open Access Journals (Sweden)

    Siddana Gouda Siddana

    2014-01-01

    Full Text Available Introduction: The imaging of the zygomatic arch is very important in the diagnosis and management of zygomatic arch fractures. It is accomplished by jug handle radiography (a variation of the submentovertex view and sometimes with modifications like the tangential or tea cup projection. For these techniques, the patient has to be positioned in a way which makes it non-applicable in cases having cervical injuries or suspected cervical injuries. Aims and Objectives: To devise a new approach with which the image of the zygomatic arch can be obtained with normal head position, in either sitting or supine position, using a dental X-ray machine and an occlusal film, which can even be used in patients with cervical injuries or suspected cervical injuries, without any complications. Materials and Methods: The present approach requires a dental X-ray machine and an occlusal X-ray film thereby eliminating the need for additional equipment like a general X-ray machine and extraoral film cassette. This approach can be carried out in a conventional dental setup to rule out zygomatic arch fractures. Conclusion: This technique can be applied in patients having cervical injuries or suspected cervical injuries, thus overcoming the drawback of the jug handle view, and is easy to master. This technique can be used in a conventional dental setup and holds good with the ALARA (as low as reasonably achievable principle of radiation protection and safety.

  9. Predicting the dissolution kinetics of silicate glasses using machine learning

    Science.gov (United States)

    Anoop Krishnan, N. M.; Mangalathu, Sujith; Smedskjaer, Morten M.; Tandia, Adama; Burton, Henry; Bauchy, Mathieu

    2018-05-01

    Predicting the dissolution rates of silicate glasses in aqueous conditions is a complex task as the underlying mechanism(s) remain poorly understood and the dissolution kinetics can depend on a large number of intrinsic and extrinsic factors. Here, we assess the potential of data-driven models based on machine learning to predict the dissolution rates of various aluminosilicate glasses exposed to a wide range of solution pH values, from acidic to caustic conditions. Four classes of machine learning methods are investigated, namely, linear regression, support vector machine regression, random forest, and artificial neural network. We observe that, although linear methods all fail to describe the dissolution kinetics, the artificial neural network approach offers excellent predictions, thanks to its inherent ability to handle non-linear data. Overall, we suggest that a more extensive use of machine learning approaches could significantly accelerate the design of novel glasses with tailored properties.

  10. A modified genetic algorithm for time and cost optimization of an additive manufacturing single-machine scheduling

    Directory of Open Access Journals (Sweden)

    M. Fera

    2018-09-01

    Full Text Available Additive Manufacturing (AM is a process of joining materials to make objects from 3D model data, usually layer by layer, as opposed to subtractive manufacturing methodologies. Selective Laser Melting, commercially known as Direct Metal Laser Sintering (DMLS®, is the most diffused additive process in today’s manufacturing industry. Introduction of a DMLS® machine in a production department has remarkable effects not only on industrial design but also on production planning, for example, on machine scheduling. Scheduling for a traditional single machine can employ consolidated models. Scheduling of an AM machine presents new issues because it must consider the capability of producing different geometries, simultaneously. The aim of this paper is to provide a mathematical model for an AM/SLM machine scheduling. The complexity of the model is NP-HARD, so possible solutions must be found by metaheuristic algorithms, e.g., Genetic Algorithms. Genetic Algorithms solve sequential optimization problems by handling vectors; in the present paper, we must modify them to handle a matrix. The effectiveness of the proposed algorithms will be tested on a test case formed by a 30 Part Number production plan with a high variability in complexity, distinct due dates and low production volumes.

  11. A technique for improving readability of Forrester diagram in system dynamics

    Directory of Open Access Journals (Sweden)

    Yang Wei-Tzen

    2003-01-01

    Full Text Available We describe a three-pass algorithm for improving the readability of Forrester Diagram in system dynamics. The first pass converts Forrester Diagram to recurrent hierarchy. The second pass sorts the vertices on each level, with the goal of minimizing crossings. The third pass is a finite tuning of the layout that determines the horizontal positions of vertices. An illustrative example is given to verify the result. .

  12. Reliability, Readability and Quality of Online Information about Femoracetabular Impingement

    Directory of Open Access Journals (Sweden)

    Fatih Küçükdurmaz

    2015-07-01

    Conclusion: According to our results, the websites intended to attract patients searching for information regarding femoroacetabular impingement are providing a highly accessible, readable information source, but do not appear to apply a comparable amount of rigor to scientific literature or healthcare practitioner websites in regard to matters such as citing sources for information, supplying methodology and including a publication date. This indicates that while these resources are easily accessed by patients, there is potential for them to be a source of misinformation.

  13. Readability Statistics of Patient Information Leaflets in a Speech and Language Therapy Department

    Science.gov (United States)

    Pothier, Louise; Day, Rachael; Harris, Catherine; Pothier, David D.

    2008-01-01

    Background: Information leaflets are commonly used in Speech and Language Therapy Departments. Despite widespread use, they can be of variable quality. Aims: To revise current departmental leaflets using the National Health Service (NHS) Toolkit for Producing Patient Information and to test the effect that this has on the readability scores of the…

  14. Medical Dataset Classification: A Machine Learning Paradigm Integrating Particle Swarm Optimization with Extreme Learning Machine Classifier

    Directory of Open Access Journals (Sweden)

    C. V. Subbulakshmi

    2015-01-01

    Full Text Available Medical data classification is a prime data mining problem being discussed about for a decade that has attracted several researchers around the world. Most classifiers are designed so as to learn from the data itself using a training process, because complete expert knowledge to determine classifier parameters is impracticable. This paper proposes a hybrid methodology based on machine learning paradigm. This paradigm integrates the successful exploration mechanism called self-regulated learning capability of the particle swarm optimization (PSO algorithm with the extreme learning machine (ELM classifier. As a recent off-line learning method, ELM is a single-hidden layer feedforward neural network (FFNN, proved to be an excellent classifier with large number of hidden layer neurons. In this research, PSO is used to determine the optimum set of parameters for the ELM, thus reducing the number of hidden layer neurons, and it further improves the network generalization performance. The proposed method is experimented on five benchmarked datasets of the UCI Machine Learning Repository for handling medical dataset classification. Simulation results show that the proposed approach is able to achieve good generalization performance, compared to the results of other classifiers.

  15. Readability of Orthopaedic Oncology-related Patient Education Materials Available on the Internet.

    Science.gov (United States)

    Shah, Akash K; Yi, Paul H; Stein, Andrew

    2015-12-01

    A person's health literacy is one of the most important indicators of a patient's health status. According to national recommendations, patient education materials should be written at no higher than the sixth- to eighth-grade reading level. The purpose of our study was to assess the readability of online patient education materials related to orthopaedic oncology on the websites of the American Academy of Orthopaedic Surgeons (AAOS), American Cancer Society (ACS), Bone and Cancer Foundation (BCF), and National Cancer Institute (NCI). We searched the online patient education libraries of the AAOS, ACS, BCF, and NCI for all articles related to orthopaedic oncology. The Flesch-Kincaid (FK) readability score was calculated for each article and compared between sources. A total of 227 articles were identified with an overall mean FK grade level of 9.8. Stratified by source, the mean FK grade levels were 10.1, 9.6, 11.1, and 9.5 for the AAOS, ACS, BCF, and NCI, respectively (P education materials related to orthopaedic oncology appear to be written at a level above the comprehension ability of the average patient. Copyright 2015 by the American Academy of Orthopaedic Surgeons.

  16. Toward the Development of a Model to Estimate the Readability of Credentialing-Examination Materials

    Science.gov (United States)

    Badgett, Barbara A.

    2010-01-01

    The purpose of this study was to develop a set of procedures to establish readability, including an equation, that accommodates the multiple-choice item format and occupational-specific language related to credentialing examinations. The procedures and equation should be appropriate for learning materials, examination materials, and occupational…

  17. LARA. Localization of an automatized refueling machine by acoustical sounding in breeder reactors - implementation of artificial intelligence techniques

    International Nuclear Information System (INIS)

    Lhuillier, C.; Malvache, P.

    1987-01-01

    The automatic control of the machine which handles the nuclear subassemblies in fast neutron reactors requires autonomous perception and decision tools. An acoustical device allows the machine to position in the work area. Artificial intelligence techniques are implemented to interpret the data: pattern recognition, scene analysis. The localization process is managed by an expert system. 6 refs.; 8 figs

  18. Point card compatible automatic vending machine for canned drink; Point card taio kan jido hanbaiki

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-01-10

    A point card compatible automatic vending machine for canned drinks is developed, which provides drink manufacturers with a powerful tool to acquire selling sites and attract consumers. Since the machine is equipped with a device to handle point cards, regular customers have increased and sales have picked up. A point card issuing device is also installed, and the new machine issues a point card whenever a customer wants. The drink manufacturers are evaluating high of the vending machine because it will contribute to the diffusion of the point card system and because a sales promotion campaign may be conducted through the vending machine for instance by exchanging a fully marked card with a giveaway on the spot. In the future, a bill validator (paper money identifier) will be integrated even with small size machines for the diffusion of point card compatible machines. (translated by NEDO)

  19. Nuclear robotics and remote handling at Harwell Laboratory

    International Nuclear Information System (INIS)

    Abel, E.; Brown, M.H.; Fischer, P.J.; Garlick, D.R.; Hanna, T.T.; Siva, K.V.

    1988-01-01

    After reviewing robotics technology and its possible application in nuclear remote handling systems of the future, six main research topics were identified where particular effort should be made. The Harwell Nuclear Robotics Programme is currently establishing sets of demonstration hardware which will allow generic research to be carried out on telerobotics, systems integration, the man machine interface, communications, servo systems and radiation tolerance. The objectives of the demonstrators are to allow validation of the techniques required for successful active facility applications such as decommissioning, decontamination, refurbishment, maintenance and repair, and to act as training aids to encourage plant designers and operators to adopt developments in new technology. (author)

  20. Track-mounted remote handling system for the Tokamak Fusion Engineering Test

    International Nuclear Information System (INIS)

    Kelly, V.P.; Berger, J.D.; Daubert, R.L.; Yount, J.A.

    1982-01-01

    Concepts for remote handling machines (IVM) designed to transverse the interior of toroidal vessels with guidance and support from track systems have been developed for the proposed Tokamak Fusion Engineering Test (TFET). TFET has been proposed as an upgrade for the Tokamak Fusion Test Reactor (TFTR), currently nearing completion. The track-mounted IVMs were conceived to perform in-vessel remote maintenance for TFET, including removal and replacement of pump limiter blades and protective tiles as well as other maintenance-related tasks such as vessel wall inspection leak testing and interior cleanup. The conceptual IVMs consist of three manipulator arms mounted on a common frame member: a single power manipulator arm with high load carrying capacity and two lower-capacity servomanipulator arms. Descriptions of the IVM concepts, in-vessel track systems, and ex-vessel handling systems are presented

  1. EVALUATION OF THE RECOMMENDED WEIGHT HANDLING LIMITS FOR LOADS IN JOINERIES

    Directory of Open Access Journals (Sweden)

    Nilton César Fiedler

    2008-06-01

    Full Text Available This study was conducted in three joineries on the South of Espírito Santo State, to analyze the weight lifted by workersduring joineries operations and to compare it with the weight limits recommended by National Institute of Occupational Safety andHealth (NIOSH. The moving of timber pieces was done manually. Data on weight handling were obtained by an accuracy scale. Thevertical and horizontal distances between load and body, the asymmetric angles and vertical displacements were obtained by directmeasurement. The lifting frequencies were analyzed throughout studies of time and movement, using a time series analysis andhandling difficult of evaluated loads through flow. According to the results, the highest load handling by workers were in the cutter andbuzzy saw machines, and was above the recommended weight limits, rendering this way of work inadequate to man.

  2. A Multiple Sensor Machine Vision System for Automatic Hardwood Feature Detection

    Science.gov (United States)

    D. Earl Kline; Richard W. Conners; Daniel L. Schmoldt; Philip A. Araman; Robert L. Brisbin

    1993-01-01

    A multiple sensor machine vision prototype is being developed to scan full size hardwood lumber at industrial speeds for automatically detecting features such as knots holes, wane, stain, splits, checks, and color. The prototype integrates a multiple sensor imaging system, a materials handling system, a computer system, and application software. The prototype provides...

  3. A Support Vector Machine Approach to Dutch Part-of-Speech Tagging

    NARCIS (Netherlands)

    Poel, Mannes; Stegeman, L.; op den Akker, Hendrikus J.A.; Berthold, M.R.; Shawe-Taylor, J.; Lavrac, N.

    Part-of-Speech tagging, the assignment of Parts-of-Speech to the words in a given context of use, is a basic technique in many systems that handle natural languages. This paper describes a method for supervised training of a Part-of-Speech tagger using a committee of Support Vector Machines on a

  4. Informed consent and the readability of the written consent form.

    Science.gov (United States)

    Sivanadarajah, N; El-Daly, I; Mamarelis, G; Sohail, M Z; Bates, P

    2017-11-01

    Introduction The aim of this study was to objectively ascertain the level of readability of standardised consent forms for orthopaedic procedures. Methods Standardised consent forms (both in summary and detailed formats) endorsed by the British Orthopaedic Association (BOA) were retrieved from orthoconsent.com and assessed for readability. This involved using an online tool to calculate the validated Flesch reading ease score (FRES). This was compared with the FRES for the National Health Service (NHS) Consent Form 1. Data were analysed and interpreted according to the FRES grading table. Results The FRES for Consent Form 1 was 55.6, relating to the literacy expected of an A level student. The mean FRES for the BOA summary consent forms (n=27) was 63.6 (95% confidence interval [CI]: 61.2-66.0) while for the detailed consent forms (n=32), it was 68.9 (95% CI: 67.7-70.0). All BOA detailed forms scored >60, correlating to the literacy expected of a 13-15-year-old. The detailed forms had a higher FRES than the summary forms (p<0.001). Conclusions This study demonstrates that the BOA endorsed standardised consent forms are much easier to read and understand than the NHS Consent Form 1, with the detailed BOA forms being the easiest to read. Despite this, owing to varying literacy levels, a significant proportion of patients may struggle to give informed consent based on the written information provided to them.

  5. Man machine interface and its implementation

    International Nuclear Information System (INIS)

    Hills, B.G.; Boettcher, D.B.; Reed, R.

    1992-01-01

    Sizewell B is the latest nuclear power station to be constructed in the United Kingdom: its Man-Machine Interfaces are therefore, by definition, the state-of-the-art. This paper discusses the principal Man-Machine Interfaces used in the operation of the station, and the systems that implement them. The Man-Machine Interface facilities discussed are: in the Main Control Room, which is used for normal operation and shutdown of the plant: in the Auxiliary Shutdown Room, which allows shutdown of the reactor if evacuation of the main Control Room is necessary: and in the Technical Support Centre, which is used for remote monitoring of the plant. The Man-Machine Interfaces that are described are parts of a station-wide group of interlinked computer systems called the Data Processing and Control System. This system collects data from the plant and displays it to the operators via discrete devices and on graphical computer displays. It also acquires control inputs from the operators via switches, which are then used to provide remote manual control, modulating control and sequence control. The computer system that handles the plant process data and alarm information displays uses a windowing interface with keyboard and trackerball navigation to allow easy retrieval and viewing of information. It is this system that is the main topic of this paper. (author)

  6. Coordination activities of human planners during rescheduling: Case analysis and event handling procedure

    OpenAIRE

    2010-01-01

    Abstract This paper addresses the process of event handling and rescheduling in manufacturing practice. Firms are confronted with many diverse events, like new or changed orders, machine breakdowns, and material shortages. These events influence the feasibility and optimality of schedules, and thus induce rescheduling. In many manufacturing firms, schedules are created by several human planners. Coordination between them is needed to respond to events adequately. In this paper,...

  7. Evaluation of Multi Canister Overpack (MCO) Handling Machine Uplift Restraint for a Seismic Event During Repositioning Operations

    International Nuclear Information System (INIS)

    SWENSON, C.E.

    2000-01-01

    Insertion of the Multi-Canister Overpack (MCO) assemblies into the Canister Storage Building (CSB) storage tubes involves the use of the MCO Handling Machine (MHM). During MCO storage tube insertion operations, inadvertent movement of the MHM is prevented by engaging seismic restraints (''active restraints'') located adjacent to both the bridge and trolley wheels. During MHM repositioning operations, the active restraints are not engaged. When the active seismic restraints are not engaged, the only functioning seismic restraints are non-engageable (''passive'') wheel uplift restraints which function only if the wheel uplift is sufficient to close the nominal 0.5-inch gap at the uplift restraint interface. The MHM was designed and analyzed in accordance with ASME NOG-1-1995. The ALSTHOM seismic analysis reported seismic loads on the MHM uplift restraints and EDERER performed corresponding structural calculations to demonstrate structural adequacy of the seismic uplift restraint hardware. The ALSTHOM and EDERER calculations were performed for a parked MHM with the active seismic restraints engaged, resulting in uplift restraint loading only in the vertical direction. In support of development of the CSB Safety Analysis Report (SAR), an evaluation of the MHM seismic response was requested for the case where the active seismic restraints are not engaged. If a seismic event occurs during MHM repositioning operations, a moving contact at a seismic uplift restraint would introduce a friction load on the restraint in the direction of the movement. These potential horizontal friction loads on the uplift restraints were not included in the existing restraint hardware design calculations. One of the purposes of the current evaluation is to address the structural adequacy of the MHM seismic uplift restraints with the addition of the horizontal friction associated with MHM repositioning movements

  8. A Functional Correspondence between Monadic Evaluators and Abstract Machines for Languages with Computational Effects

    DEFF Research Database (Denmark)

    Ager, Mads Sig; Danvy, Olivier; Midtgaard, Jan

    2005-01-01

    We extend our correspondence between evaluators and abstract machines from the pure setting of the lambda-calculus to the impure setting of the computational lambda-calculus. We show how to derive new abstract machines from monadic evaluators for the computational lambda-calculus. Starting from (1......) a generic evaluator parameterized by a monad and (2) a monad specifying a computational effect, we inline the components of the monad in the generic evaluator to obtain an evaluator written in a style that is specific to this computational effect. We then derive the corresponding abstract machine by closure......-converting, CPS-transforming, and defunctionalizing this specific evaluator. We illustrate the construction first with the identity monad, obtaining the CEK machine, and then with a lifting monad, a state monad, and with a lifted state monad, obtaining variants of the CEK machine with error handling, state...

  9. Assessing the Readability of College Textbooks in Public Speaking: Attending to Entry Level Instruction

    Science.gov (United States)

    Schneider, David E.

    2011-01-01

    More research is needed that examines textbooks intended for the entry level college classroom. This study offers valuable information to academics that adopt a public speaking textbook for instruction as well as objective feedback to the collective authors. Readability levels of 22 nationally published textbooks, based on McGlaughlin's (1969)…

  10. Translation Analysis on Civil Engineering Text Produced by Machine Translator

    Directory of Open Access Journals (Sweden)

    Sutopo Anam

    2018-01-01

    Full Text Available Translation is extremely needed in communication since people have serious problem in the language used. Translation activity is done by the person in charge for translating the material. Translation activity is also able to be done by machine. It is called machine translation, reflected in the programs developed by programmer. One of them is Transtool. Many people used Transtool for helping them in solving the problem related with translation activities. This paper wants to deliver how important is the Transtool program, how effective is Transtool program and how is the function of Transtool for human business. This study applies qualitative research. The sources of data were document and informant. This study used documentation and in dept-interviewing as the techniques for collecting data. The collected data were analyzed by using interactive analysis. The results of the study show that, first; Transtool program is helpful for people in translating the civil engineering text and it functions as the aid or helper, second; the working of Transtool software program is effective enough and third; the result of translation produced by Transtool is good for short and simple sentences and not readable, not understandable and not accurate for long sentences (compound, complex and compound complex thought the result is informative. The translated material must be edited by the professional translator.

  11. Translation Analysis on Civil Engineering Text Produced by Machine Translator

    Science.gov (United States)

    Sutopo, Anam

    2018-02-01

    Translation is extremely needed in communication since people have serious problem in the language used. Translation activity is done by the person in charge for translating the material. Translation activity is also able to be done by machine. It is called machine translation, reflected in the programs developed by programmer. One of them is Transtool. Many people used Transtool for helping them in solving the problem related with translation activities. This paper wants to deliver how important is the Transtool program, how effective is Transtool program and how is the function of Transtool for human business. This study applies qualitative research. The sources of data were document and informant. This study used documentation and in dept-interviewing as the techniques for collecting data. The collected data were analyzed by using interactive analysis. The results of the study show that, first; Transtool program is helpful for people in translating the civil engineering text and it functions as the aid or helper, second; the working of Transtool software program is effective enough and third; the result of translation produced by Transtool is good for short and simple sentences and not readable, not understandable and not accurate for long sentences (compound, complex and compound complex) thought the result is informative. The translated material must be edited by the professional translator.

  12. Computer-Based Readability Testing of Information Booklets for German Cancer Patients.

    Science.gov (United States)

    Keinki, Christian; Zowalla, Richard; Pobiruchin, Monika; Huebner, Jutta; Wiesner, Martin

    2018-04-12

    Understandable health information is essential for treatment adherence and improved health outcomes. For readability testing, several instruments analyze the complexity of sentence structures, e.g., Flesch-Reading Ease (FRE) or Vienna-Formula (WSTF). Moreover, the vocabulary is of high relevance for readers. The aim of this study is to investigate the agreement of sentence structure and vocabulary-based (SVM) instruments. A total of 52 freely available German patient information booklets on cancer were collected from the Internet. The mean understandability level L was computed for 51 booklets. The resulting values of FRE, WSTF, and SVM were assessed pairwise for agreement with Bland-Altman plots and two-sided, paired t tests. For the pairwise comparison, the mean L values are L FRE  = 6.81, L WSTF  = 7.39, L SVM  = 5.09. The sentence structure-based metrics gave significantly different scores (P < 0.001) for all assessed booklets, confirmed by the Bland-Altman analysis. The study findings suggest that vocabulary-based instruments cannot be interchanged with FRE/WSTF. However, both analytical aspects should be considered and checked by authors to linguistically refine texts with respect to the individual target group. Authors of health information can be supported by automated readability analysis. Health professionals can benefit by direct booklet comparisons allowing for time-effective selection of suitable booklets for patients.

  13. New series of paper pack vending machines; Paper pack jido hanbaiki no shin series

    Energy Technology Data Exchange (ETDEWEB)

    Ohashi, M. [Fuji Denki Reiki Co. Ltd., Tokyo (Japan); Umino, S. [Fuji Electric Co. Ltd., Tokyo (Japan)

    1996-07-10

    This paper presents series of paper pack vending machines. These machines may be broadly classified into those of cold drinks and of hot and cold drinks depending on the storage temperature of products. The former is the machine for cooling dairy products at 10{degree}C with a combined stacking by direct-stacked racks and chain-multiracks. The latter is provided with divided storing chambers with each chamber selectively cooled or heated. Products in the hot chamber are canned coffee and the like set at 55{degree}C. The temperature control is performed by a microcomputer. The chain-multiracks are provided with advantages such as capability of handling various kinds of container shapes, storing drinks and foods vertically, replacing products by the change of a shelf attachment with one operation, and storing one liter packs by setting pair columns. The direct-stacked racks are provided with advantages such as versatility of handling various kinds of containers and miniaturization of the mechanism other than the storage part. The installation space was reduced by devising the opening and closing of the door. The control part is capable of setting temperatures differently for cans and paper packs. 7 figs., 1 tab.

  14. Numerical simulator of the CANDU fueling machine driving desk

    International Nuclear Information System (INIS)

    Doca, Cezar

    2008-01-01

    As a national and European premiere, in the 2003 - 2005 period, at the Institute for Nuclear Research Pitesti two CANDU fueling machine heads, no.4 and no.5, for the Nuclear Power Plant Cernavoda - Unit 2 were successfully tested. To perform the tests of these machines, a special CANDU fueling machine testing rig was built and was (and is) available for this goal. The design of the CANDU fueling machine test rig from the Institute for Nuclear Research Pitesti is a replica of the similar equipment operating in CANDU 6 type nuclear power plants. High technical level of the CANDU fueling machine tests required the using of an efficient data acquisition and processing Computer Control System. The challenging goal was to build a computer system (hardware and software) designed and engineered to control the test and calibration process of these fuel handling machines. The design takes care both of the functionality required to correctly control the CANDU fueling machine and of the additional functionality required to assist the testing process. Both the fueling machine testing rig and staff had successfully assessed by the AECL representatives during two missions. At same the time, at the Institute for Nuclear Research Pitesti was/is developed a numerical simulator for the CANDU fueling machine operators training. The paper presents the numerical simulator - a special PC program (software) which simulates the graphics and the functions and the operations at the main desk of the computer control system. The simulator permits 'to drive' a CANDU fueling machine in two manners: manual or automatic. The numerical simulator is dedicated to the training of operators who operate the CANDU fueling machine in a nuclear power plant with CANDU reactor. (author)

  15. FFTF [Fast Flux Test Facility] fuel handling experience (1979--1986)

    International Nuclear Information System (INIS)

    Romrell, D.M.; Art, D.M.; Redekopp, R.D.; Waldo, J.B.

    1987-05-01

    The Fast Flux Test Facility (FFTF)is a 400 MW (th) sodium-cooled fast flux test reactor located on the Hanford Site in southeastern Washington State. The FFTF is operated by the Westinghouse Hanford Company for the United States Department of Energy. The FFTF is a three loop plant designed primarily for the purpose of testing full-scale core components in an environment prototypic of future liquid metal reactors. The plant design emphasizes features to enhance this test capability, especially in the area of the core, reactor vessel, and refueling system. Eight special test positions are provided in the vessel head to permit contact instrumented experiments to be installed and irradiated. These test positions effectively divide the core into three sectors. Each sector requires its own In-Vessel Handling Machine (IVHM) to access all the core positions. Since the core and the in-vessel refueling components are submerged under sodium, all handling operations must be performed blind. This puts severe requirements on the positioning ability are reliability of the refueling components. This report addresses the operating experience with the fuel handling system from initial core loading in November, 1979 through 1986. This includes 9 refueling cycles. 2 refs., 8 figs

  16. Fusion reactor handling operations with cable-driven parallel robots

    Energy Technology Data Exchange (ETDEWEB)

    Izard, Jean-Baptiste, E-mail: jeanbaptiste.izard@tecnalia.com; Michelin, Micael; Baradat, Cédric

    2015-10-15

    Highlights: • CDPR allow 6DOF positioning of loads using cable as links without payload swag. • Conceptual design of a CDPR for carrying and positioning tokamak sectors is given. • A CDPR for threading stellarator coils (6D trajectory following) is provided. • Both designs are capable of fullfilling the required precision without tooling. - Abstract: Cable-driven parallel robots (CDPR) are in their concept cranes with inclined cables which allow control of all the degrees of freedom of its payload, and therefore stability of all the degrees of freedom, including rotations. The workspace of a CDPR is only limited by the length of the cables, and the payload capacity related to the mass of the whole robot is very important. Besides, the control being based on kinematic models, the behavior of a CDPR is really that of a robot capable of automated trajectories or remote handling. The present paper gives a presentation of two use case studies based on some of the assembly phases and remote handling actions as designed for the recent fusion machines. Based on the use cases already in place in fusion reactor baselines, the opportunity of using CDPR for assembly of structural elements and coils is discussed. Finally, prospects for remote handling equipment from the reactor in hot cells are envisioned based on current CDPR research.

  17. Repurposing mainstream CNC machine tools for laser-based additive manufacturing

    Science.gov (United States)

    Jones, Jason B.

    2016-04-01

    The advent of laser technology has been a key enabler for industrial 3D printing, known as Additive Manufacturing (AM). Despite its commercial success and unique technical capabilities, laser-based AM systems are not yet able to produce parts with the same accuracy and surface finish as CNC machining. To enable the geometry and material freedoms afforded by AM, yet achieve the precision and productivity of CNC machining, hybrid combinations of these two processes have started to gain traction. To achieve the benefits of combined processing, laser technology has been integrated into mainstream CNC machines - effectively repurposing them as hybrid manufacturing platforms. This paper reviews how this engineering challenge has prompted beam delivery innovations to allow automated changeover between laser processing and machining, using standard CNC tool changers. Handling laser-processing heads using the tool changer also enables automated change over between different types of laser processing heads, further expanding the breadth of laser processing flexibility in a hybrid CNC. This paper highlights the development, challenges and future impact of hybrid CNCs on laser processing.

  18. SELECTION OF ONTOLOGY FOR WEB SERVICE DESCRIPTION LANGUAGE TO ONTOLOGY WEB LANGUAGE CONVERSION

    OpenAIRE

    J. Mannar Mannan; M. Sundarambal; S. Raghul

    2014-01-01

    Semantic web is to extend the current human readable web to encoding some of the semantic of resources in a machine processing form. As a Semantic web component, Semantic Web Services (SWS) uses a mark-up that makes the data into detailed and sophisticated machine readable way. One such language is Ontology Web Language (OWL). Existing conventional web service annotation can be changed to semantic web service by mapping Web Service Description Language (WSDL) with the semantic annotation of O...

  19. GCP compliance and readability of informed consent forms from an emerging hub for clinical trials

    Directory of Open Access Journals (Sweden)

    Satish Chandrasekhar Nair

    2015-01-01

    Full Text Available Background: The rapid expansion of trials in emerging regions has raised valid concerns about research subject protection, particularly related to informed consent. The purpose of this study is to assess informed consent form (ICF compliance with Good Clinical Practice (GCP guidelines and the readability easeof the ICFs in Abu Dhabi, a potential destination for clinical trials in the UAE. Materials and Methods: A multicenter retrospective cross-sectional analysis of 140 ICFs from industry sponsored and non-sponsored studies was conducted by comparing against a local standard ICF. Flesch-Kincaid Reading Scale was used to assess the readability ease of the forms. Results: Non-sponsored studies had signifi cantly lower overall GCP compliance of 55.8% when compared to 79.5% for industry sponsored studies. Only 33% of sponsored and 16% of non-sponsored studies included basic information on the participants′ rights and responsibilities. Flesch-Kincaid Reading ease score for the informed consent forms from industry sponsored studies was signifi cantly higher 48.9 ± 4.8 as compared to 38.5 ± 8.0 for non-sponsored studies, though both were more complex than recommended. Reading Grade Level score was also higher than expected, but scores for the ICFs from the industry sponsored studies were 9.7 ± 0.7, signifi cantly lower as compared to 12.2 ± 1.3 for non-sponsored studies. Conclusion: In spite of the undisputed benefits of conducting research in emerging markets readability, comprehension issues and the lack of basic essential information call for improvements in the ICFs to protect the rights of future research subjects enrolled in clinical trials in the UAE.

  20. ADAPTING HYBRID MACHINE TRANSLATION TECHNIQUES FOR CROSS-LANGUAGE TEXT RETRIEVAL SYSTEM

    Directory of Open Access Journals (Sweden)

    P. ISWARYA

    2017-03-01

    Full Text Available This research work aims in developing Tamil to English Cross - language text retrieval system using hybrid machine translation approach. The hybrid machine translation system is a combination of rule based and statistical based approaches. In an existing word by word translation system there are lot of issues and some of them are ambiguity, Out-of-Vocabulary words, word inflections, and improper sentence structure. To handle these issues, proposed architecture is designed in such a way that, it contains Improved Part-of-Speech tagger, machine learning based morphological analyser, collocation based word sense disambiguation procedure, semantic dictionary, and tense markers with gerund ending rules, and two pass transliteration algorithm. From the experimental results it is clear that the proposed Tamil Query based translation system achieves significantly better translation quality over existing system, and reaches 95.88% of monolingual performance.

  1. Readability of alphanumeric characters having various contrast levels as a function of age and illumination mode.

    Science.gov (United States)

    1977-07-01

    Readability data of alphanumeric characters that vary in figure-to- ground contrast ratio were obtained from 36 subjects; 12 subjects were placed in each of three age groups (20-25 yr, 40-45 yr, and 60-65 yr). Minimum illuminance required to identify...

  2. Readability of the Most Commonly Accessed Arthroscopy-Related Online Patient Education Materials.

    Science.gov (United States)

    Akinleye, Sheriff D; Krochak, Ryan; Richardson, Nicholas; Garofolo, Garret; Culbertson, Maya Deza; Erez, Orry

    2018-04-01

    To assess the readability and comprehension of written text by the most commonly visited websites containing patient education materials on common conditions that can be treated arthroscopically. We examined 50 websites, assessed independently by 2 orthopaedic surgery residents (S.A. and G.G.), with educational materials on 5 common conditions treated by arthroscopic surgeons: anterior cruciate ligament (ACL) tear, meniscus tear, hip labral tear, shoulder labral tear, and rotator cuff tear. Following a Google search for each condition, we analyzed the 10 most visited websites for each disorder using a widely used and validated tool for assessing the reading levels of written materials (Flesch-Kincaid formula). The average grade reading level of the 50 websites studied was 9.90 with a reading ease of 52.14 ("fairly difficult, high school"). Only 26% of the websites were at or below the national average of an eighth-grade reading level. Of the 5 conditions treated by arthroscopic surgery, ACL tear had the highest average grade reading level at 10.73 ± 1.54, whereas meniscus tear had the lowest at 9.31 ± 1.81. Every condition in this study had an average readability at or above the ninth-grade reading level. The most frequently accessed materials for patients with injuries requiring arthroscopic surgery exceeds the readability recommendations of the American Medical Association and National Institutes of Health, as well as the average reading ability of US adults. Given the fact that these are the most commonly visited websites by the lay public, there needs to be a greater emphasis on tailoring written information to the literacy levels of the patient population. This study emphasizes the discrepancy between the recommended versus the measured reading levels of online patient education materials related to conditions treated by arthroscopic surgeons. The subject matter of these conditions is inherently complex; thus, relying solely on text to inform patients

  3. Evaluation of completeness of selected poison control center data fields.

    Science.gov (United States)

    Jaramillo, Jeanie E; Marchbanks, Brenda; Willis, Branch; Forrester, Mathias B

    2010-08-01

    Poison control center data are used in research and surveillance. Due to the large volume of information, these efforts are dependent on data being recorded in machine readable format. However, poison center records include non-machine readable text fields and machine readable coded fields, some of which are duplicative. Duplicating this data increases the chance of inaccurate/incomplete coding. For surveillance efforts to be effective, coding should be complete and accurate. Investigators identified a convenience sample of 964 records and reviewed the substance code determining if it matched its text field. They also reviewed the coded clinical effects and treatments determining if they matched the notes text field. The substance code matched its text field for 91.4% of the substances. The clinical effects and treatments codes matched their text field for 72.6% and 82.4% of occurrences respectively. This under-reporting of clinical effects and treatments has surveillance and public health implications.

  4. Improving Readability of an Evaluation Tool for Low-Income Clients Using Visual Information Processing Theories

    Science.gov (United States)

    Townsend, Marilyn S.; Sylva, Kathryn; Martin, Anna; Metz, Diane; Wooten-Swanson, Patti

    2008-01-01

    Literacy is an issue for many low-income audiences. Using visual information processing theories, the goal was improving readability of a food behavior checklist and ultimately improving its ability to accurately capture existing changes in dietary behaviors. Using group interviews, low-income clients (n = 18) evaluated 4 visual styles. The text…

  5. Fuel handling problems at KANUPP

    International Nuclear Information System (INIS)

    Ahmed, I.; Mazhar Hasan, S.; Mugtadir, A.

    1991-01-01

    KANUPP experienced two abnormal fuel and fuel handling related problems during the year 1990. One of these had arisen due to development of end plate to end plate coupling between the two bundles at the leading end of the fuel string in channel HO2-S. The incident occurred when attempts were being made to fuel this channel. Due to pulling of sticking bundles into the acceptor fuelling machine (north) magazine, which was not designed to accommodate two bundles, a magazine rotary stop occurred. The forward motion of the charge tube was simultaneously discovered to be restricted. The incident led to stalling of fuelling machine locked on to the channel HO2, necessitating a reactor shut down. Removal of the fuelling machine was accomplished sometime later after draining of the channel. The second incident which made the fuelling of channel KO5-N temporarily inexecutable, occurred during attempts to remove its north end shield plug when this channel came up for fuelling. The incident resulted due to breaking of the lugs of the shield plug, making its withdrawal impossible. The Plant however kept operating with suspended fuelling of channel KO5, until it could no longer sustain a further increase in fuel burnup at the maximum rating position. Resolving both these problems necessitated draining of the respective channels, leaving the resident fuel uncovered for the duration of the associated operation. Due to substantial difference in the oxidation temperatures Of UO 2 and Zircaloy and its influence as such on the cooling requirement, it was necessary either to determine explicitly that the respective channels did not contain defective fuel bundles or wait for time long enough to allow the decay heat to reduce to manageable proportions. This had a significant bearing on the Plant down time necessary for the rectification of the problems. This paper describes the two incidents in detail and dwells upon the measures adopted to resolve the related problems. (author)

  6. Fuel handling problems at KANUPP

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, I; Mazhar Hasan, S; Mugtadir, A [Karachi Nuclear Power Plant (KANUPP), Karachi (Pakistan)

    1991-04-01

    KANUPP experienced two abnormal fuel and fuel handling related problems during the year 1990. One of these had arisen due to development of end plate to end plate coupling between the two bundles at the leading end of the fuel string in channel HO2-S. The incident occurred when attempts were being made to fuel this channel. Due to pulling of sticking bundles into the acceptor fuelling machine (north) magazine, which was not designed to accommodate two bundles, a magazine rotary stop occurred. The forward motion of the charge tube was simultaneously discovered to be restricted. The incident led to stalling of fuelling machine locked on to the channel HO2, necessitating a reactor shut down. Removal of the fuelling machine was accomplished sometime later after draining of the channel. The second incident which made the fuelling of channel KO5-N temporarily inexecutable, occurred during attempts to remove its north end shield plug when this channel came up for fuelling. The incident resulted due to breaking of the lugs of the shield plug, making its withdrawal impossible. The Plant however kept operating with suspended fuelling of channel KO5, until it could no longer sustain a further increase in fuel burnup at the maximum rating position. Resolving both these problems necessitated draining of the respective channels, leaving the resident fuel uncovered for the duration of the associated operation. Due to substantial difference in the oxidation temperatures Of UO{sub 2} and Zircaloy and its influence as such on the cooling requirement, it was necessary either to determine explicitly that the respective channels did not contain defective fuel bundles or wait for time long enough to allow the decay heat to reduce to manageable proportions. This had a significant bearing on the Plant down time necessary for the rectification of the problems. This paper describes the two incidents in detail and dwells upon the measures adopted to resolve the related problems. (author)

  7. A man-machine interface for simulation purposes

    International Nuclear Information System (INIS)

    Galan, J.M.; Almeida, J.M.; Duque, J.M.

    1990-01-01

    This paper describes a man-machine interface, to link any simulator program to a control panel made up of an array of color graphic screens. This task is performed by a communications program which extracts the data from the simulator program, sorts the data, and sends it, through the network, to graphics programs running in workstations. There, the data is displayed on color graphic screens. A graphics package was specifically designed to assist the user handling of complex circuits, and the formatting and display of data on the screens. (author)

  8. Automation of a universal machine; Automatizacion de una maquina universal

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez S, J

    1997-09-01

    The development of the hardware and software of a control system for a servo-hydraulic machine is presented. The universal machine is an Instron, model 1331, used to make mechanical tests. The software includes the acquisition of data from the measurements, processing and graphic presentation of the results in the assay of the `tension` type. The control is based on a PPI (Programmable Peripheral Interface) 8255, in which the different states of the machine are set. The control functions of the machine are: (a) Start of an assay, (b) Pause in the assay, (c) End of the assay, (d) Choice of the control mode of the machine, that they could be in load, stroke or strain modes. For the data acquisition, a commercial card, National Products, model DAS-16, plugged in a slot of a Pc was used. Three transducers provide the analog signals, a cell of load, a LVDT and a extensometer. All the data are digitalized and handled in order to get the results in the appropriate working units. A stress-strain graph is obtained in the screen of the Pc for a tension test for a specific material. The points of maximum stress, rupture stress and the yield stress of the material under test are shown. (Author).

  9. Readability Assessment of Internet-Based Patient Education Materials Related to Parathyroid Surgery.

    Science.gov (United States)

    Patel, Chirag R; Sanghvi, Saurin; Cherla, Deepa V; Baredes, Soly; Eloy, Jean Anderson

    2015-07-01

    Patient education is critical in obtaining informed consent and reducing preoperative anxiety. Written patient education material (PEM) can supplement verbal communication to improve understanding and satisfaction. Published guidelines recommend that health information be presented at or below a sixth-grade reading level to facilitate comprehension. We investigate the grade level of online PEMs regarding parathyroid surgery. A popular internet search engine was used to identify PEM discussing parathyroid surgery. Four formulas were used to calculate readability scores: Flesch Reading Ease (FRE), Flesch-Kincaid Grade Level (FKGL), Gunning Frequency of Gobbledygook (GFOG), and Simple Measure of Gobbledygook (SMOG). Thirty web-based articles discussing parathyroid surgery were identified. The average FRE score was 42.8 (±1 standard deviation [SD] 16.3; 95% confidence interval [CI], 36.6-48.8; range, 6.1-71.3). The average FKGL score was 11.7 (±1 SD 3.3; 95% CI, 10.5-12.9; range, 6.1-19.0). The SMOG scores averaged 14.2 (±1 SD 2.6; 95% CI, 13.2-15.2; range, 10.7-21.9), and the GFOG scores averaged 15.0 (±1 SD 3.5; 95% CI, 13.7-16.3; range, 10.6-24.8). Online PEM on parathyroid surgery is written above the recommended sixth-grade reading level. Improving readability of PEM may promote better health education and compliance. © The Author(s) 2015.

  10. Health Literacy: Readability of ACC/AHA Online Patient Education Material.

    Science.gov (United States)

    Kapoor, Karan; George, Praveen; Evans, Matthew C; Miller, Weldon J; Liu, Stanley S

    To determine whether the online patient education material offered by the American College of Cardiology (ACC) and the American Heart Association (AHA) is written at a higher level than the 6th-7th grade level recommended by the National Institute of Health (NIH). Online patient education material from each website was subjected to reading grade level (RGL) analysis using the Readability Studio Professional Edition. One-sample t testing was used to compare the mean RGLs obtained from 8 formulas to the NIH-recommended 6.5 grade level and 8th grade national mean. In total, 372 articles from the ACC website and 82 from the AHA were studied. Mean (±SD) RGLs for the 454 articles were 9.6 ± 2.1, 11.2 ± 2.1, 11.9 ± 1.6, 10.8 ± 1.6, 9.7 ± 2.1, 10.8 ± 0.8, 10.5 ± 2.6, and 11.7 ± 3.5 according to the Flesch-Kincaid grade level (FKGL), Simple Measure of Gobbledygook (SMOG Index), Coleman-Liau Index (CLI), Gunning-Fog Index (GFI), New Dale-Chall reading level formula (NDC), FORCAST, Raygor Readability Estimate (RRE), and Fry Graph (Fry), respectively. All analyzed articles had significantly higher RGLs than both the NIH-recommended grade level of 6.5 and the national mean grade level of 8 (p education material provided on the ACC and AHA websites is written above the NIH-recommended 6.5 grade level and 8th grade national mean reading level. Additional studies are required to demonstrate whether lowering the RGL of this material improves outcomes among patients with cardiovascular disease. © 2017 S. Karger AG, Basel.

  11. Distributed state machine supervision for long-baseline gravitational-wave detectors

    International Nuclear Information System (INIS)

    Rollins, Jameson Graef

    2016-01-01

    The Laser Interferometer Gravitational-wave Observatory (LIGO) consists of two identical yet independent, widely separated, long-baseline gravitational-wave detectors. Each Advanced LIGO detector consists of complex optical-mechanical systems isolated from the ground by multiple layers of active seismic isolation, all controlled by hundreds of fast, digital, feedback control systems. This article describes a novel state machine-based automation platform developed to handle the automation and supervisory control challenges of these detectors. The platform, called Guardian, consists of distributed, independent, state machine automaton nodes organized hierarchically for full detector control. User code is written in standard Python and the platform is designed to facilitate the fast-paced development process associated with commissioning the complicated Advanced LIGO instruments. While developed specifically for the Advanced LIGO detectors, Guardian is a generic state machine automation platform that is useful for experimental control at all levels, from simple table-top setups to large-scale multi-million dollar facilities.

  12. Distributed state machine supervision for long-baseline gravitational-wave detectors

    Energy Technology Data Exchange (ETDEWEB)

    Rollins, Jameson Graef, E-mail: jameson.rollins@ligo.org [LIGO Laboratory, California Institute of Technology, Pasadena, California 91125 (United States)

    2016-09-15

    The Laser Interferometer Gravitational-wave Observatory (LIGO) consists of two identical yet independent, widely separated, long-baseline gravitational-wave detectors. Each Advanced LIGO detector consists of complex optical-mechanical systems isolated from the ground by multiple layers of active seismic isolation, all controlled by hundreds of fast, digital, feedback control systems. This article describes a novel state machine-based automation platform developed to handle the automation and supervisory control challenges of these detectors. The platform, called Guardian, consists of distributed, independent, state machine automaton nodes organized hierarchically for full detector control. User code is written in standard Python and the platform is designed to facilitate the fast-paced development process associated with commissioning the complicated Advanced LIGO instruments. While developed specifically for the Advanced LIGO detectors, Guardian is a generic state machine automation platform that is useful for experimental control at all levels, from simple table-top setups to large-scale multi-million dollar facilities.

  13. A Bit-Encoding Based New Data Structure for Time and Memory Efficient Handling of Spike Times in an Electrophysiological Setup.

    Science.gov (United States)

    Ljungquist, Bengt; Petersson, Per; Johansson, Anders J; Schouenborg, Jens; Garwicz, Martin

    2018-04-01

    Recent neuroscientific and technical developments of brain machine interfaces have put increasing demands on neuroinformatic databases and data handling software, especially when managing data in real time from large numbers of neurons. Extrapolating these developments we here set out to construct a scalable software architecture that would enable near-future massive parallel recording, organization and analysis of neurophysiological data on a standard computer. To this end we combined, for the first time in the present context, bit-encoding of spike data with a specific communication format for real time transfer and storage of neuronal data, synchronized by a common time base across all unit sources. We demonstrate that our architecture can simultaneously handle data from more than one million neurons and provide, in real time (based on analysis of previously recorded data. In addition to managing recordings from very large numbers of neurons in real time, it also has the capacity to handle the extensive periods of recording time necessary in certain scientific and clinical applications. Furthermore, the bit-encoding proposed has the additional advantage of allowing an extremely fast analysis of spatiotemporal spike patterns in a large number of neurons. Thus, we conclude that this architecture is well suited to support current and near-future Brain Machine Interface requirements.

  14. Evaluating the Quality, Accuracy, and Readability of Online Resources Pertaining to Hallux Valgus.

    Science.gov (United States)

    Tartaglione, Jason P; Rosenbaum, Andrew J; Abousayed, Mostafa; Hushmendy, Shazaan F; DiPreta, John A

    2016-02-01

    The Internet is one of the most widely utilized resources for health-related information. Evaluation of the medical literature suggests that the quality and accuracy of these resources are poor and written at inappropriately high reading levels. The purpose of our study was to evaluate the quality, accuracy, and readability of online resources pertaining to hallux valgus. Two search terms ("hallux valgus" and "bunion") were entered into Google, Yahoo, and Bing. With the use of scoring criteria specific to hallux valgus, the quality and accuracy of online information related to hallux valgus was evaluated by 3 reviewers. The Flesch-Kincaid score was used to determine readability. Statistical analysis was performed with t tests and significance was determined by P values hallux valgus" (P = .045). Quality and accuracy were significantly higher in resources authored by physicians as compared to nonphysicians (quality, P = .04; accuracy, P hallux valgus is poor and written at inappropriate reading levels. Furthermore, the search term used, authorship, and presence of commercial bias influence the value of these materials. It is important for orthopaedic surgeons to become familiar with patient education materials, so that appropriate recommendations can be made regarding valuable resources. Level IV. © 2015 The Author(s).

  15. Classifying Structures in the ISM with Machine Learning Techniques

    Science.gov (United States)

    Beaumont, Christopher; Goodman, A. A.; Williams, J. P.

    2011-01-01

    The processes which govern molecular cloud evolution and star formation often sculpt structures in the ISM: filaments, pillars, shells, outflows, etc. Because of their morphological complexity, these objects are often identified manually. Manual classification has several disadvantages; the process is subjective, not easily reproducible, and does not scale well to handle increasingly large datasets. We have explored to what extent machine learning algorithms can be trained to autonomously identify specific morphological features in molecular cloud datasets. We show that the Support Vector Machine algorithm can successfully locate filaments and outflows blended with other emission structures. When the objects of interest are morphologically distinct from the surrounding emission, this autonomous classification achieves >90% accuracy. We have developed a set of IDL-based tools to apply this technique to other datasets.

  16. Quantitative analysis of the level of readability of online emergency radiology-based patient education resources.

    Science.gov (United States)

    Hansberry, David R; D'Angelo, Michael; White, Michael D; Prabhu, Arpan V; Cox, Mougnyan; Agarwal, Nitin; Deshmukh, Sandeep

    2018-04-01

    The vast amount of information found on the internet, combined with its accessibility, makes it a widely utilized resource for Americans to find information pertaining to medical information. The field of radiology is no exception. In this paper, we assess the readability level of websites pertaining specifically to emergency radiology. Using Google, 23 terms were searched, and the top 10 results were recorded. Each link was evaluated for its readability level using a set of ten reputable readability scales. The search terms included the following: abdominal ultrasound, abdominal aortic aneurysm, aortic dissection, appendicitis, cord compression, CT abdomen, cholecystitis, CT chest, diverticulitis, ectopic pregnancy, epidural hematoma, dural venous thrombosis, head CT, MRI brain, MR angiography, MRI spine, ovarian torsion, pancreatitis, pelvic ultrasound, pneumoperitoneum, pulmonary embolism, subarachnoid hemorrhage, and subdural hematoma. Any content that was not written for patients was excluded. The 230 articles that were assessed were written, on average, at a 12.1 grade level. Only 2 of the 230 articles (1%) were written at the third to seventh grade recommended reading level set forth by the National Institutes of Health (NIH) and American Medical Association (AMA). Fifty-two percent of the 230 articles were written so as to require a minimum of a high school education (at least a 12th grade level). Additionally, 17 of the 230 articles (7.3%) were written at a level that exceeded an undergraduate education (at least a 16th grade level). The majority of websites with emergency radiology-related patient education materials are not adhering to the NIH and AMA's recommended reading levels, and it is likely that the average reader is not benefiting fully from these information outlets. With the link between health literacy and poor health outcomes, it is important to address the online content in this area of radiology, allowing for patient to more fully benefit

  17. Augmented reality with image registration, vision correction and sunlight readability via liquid crystal devices.

    Science.gov (United States)

    Wang, Yu-Jen; Chen, Po-Ju; Liang, Xiao; Lin, Yi-Hsin

    2017-03-27

    Augmented reality (AR), which use computer-aided projected information to augment our sense, has important impact on human life, especially for the elder people. However, there are three major challenges regarding the optical system in the AR system, which are registration, vision correction, and readability under strong ambient light. Here, we solve three challenges simultaneously for the first time using two liquid crystal (LC) lenses and polarizer-free attenuator integrated in optical-see-through AR system. One of the LC lens is used to electrically adjust the position of the projected virtual image which is so-called registration. The other LC lens with larger aperture and polarization independent characteristic is in charge of vision correction, such as myopia and presbyopia. The linearity of lens powers of two LC lenses is also discussed. The readability of virtual images under strong ambient light is solved by electrically switchable transmittance of the LC attenuator originating from light scattering and light absorption. The concept demonstrated in this paper could be further extended to other electro-optical devices as long as the devices exhibit the capability of phase modulations and amplitude modulations.

  18. Handling of multiassembly sealed baskets between reactor storage and a remote handling facility

    International Nuclear Information System (INIS)

    Massey, J.V.; Kessler, J.H.; McSherry, A.J.

    1989-06-01

    The storage of multiple fuel assemblies in sealed (welded) dry storage baskets is gaining increasing use to augment at-reactor fuel storage capacity. Since this increasing use will place a significant number of such baskets on reactor sites, some initial downstream planning for their future handling scenarios for retrieving multi-assembly sealed baskets (MSBs) from onsite storage and transferring and shipping the fuel (and/or the baskets) to a federally operated remote handling facility (RHF). Numerous options or at-reactor and away-from-reactor handling were investigated. Materials handling flowsheets were developed along with conceptual designs for the equipment and tools required to handle and open the MSBs. The handling options were evaluated and compared to a reference case, fuel handling sequence (i.e., fuel assemblies are taken from the fuel pool, shipped to a receiving and handling facility and placed into interim storage). The main parameters analyzed are throughout, radiation dose burden and cost. In addition to evaluating the handling of MSBs, this work also evaluated handling consolidated fuel canisters (CFCs). In summary, the handling of MSBs and CFCs in the store, ship and bury fuel cycle was found to be feasible and, under some conditions, to offer significant benefits in terms of throughput, cost and safety. 14 refs., 20 figs., 24 tabs

  19. An automated tensile machine for small specimens heavily neutron irradiated in FFTF/MOTA

    International Nuclear Information System (INIS)

    Kohyama, Akira; Sato, Shinji; Hamada, Kenichi

    1993-01-01

    The objective of this work is to develop a fully automated tensile machine for post-irradiation examination (PIE) of Fast Flux Test Facility (FFTF)/Materials Open Test Assembly (MOTA) irradiated miniature tension specimens. The anticipated merit of the automated tensile machine is to reduce damage to specimens during specimen handling for PIE and to reduce exposure to radioactive specimens. This machine is designed for testing at elevated temperatures, up to 873 K, in a vacuum or in an inert gas environment. Twelve specimen assemblies are placed in the vacuum chamber that can be tested successively in a fully automated manner. A unique automated tensile machine for the PIE of FFTF/MOTA irradiated specimens, the Monbusho Automated Tensile Machine (MATRON) consists of a test frame with controlling units and an automated specimen-loading apparatus. The qualification of the test frame has been completed, and the results have satisfied the machine specifications. The capabilities of producing creep and relaxation data have been demonstrated for Cu, Al, 316SS, and ferritic steels. The specimen holders for the three-point bending test and the small bulge test (small punch test; SP test) were also designed and produced

  20. OMS event evaluator and scheduler

    Science.gov (United States)

    Eckelkamp, Richard E.

    1990-01-01

    An Operations Management System (OMS) is being designed for Space Station Freedom to improve productivity, reliability, and safety while reducing operations and maintenance costs. Central to the concept is a short term plan containing mixes of man-readable and machine-executable procedures used in an environment of distributed processing and execution. An OMS event evaluator to check upcoming short-term plan events for validity of execution is under development. The first version checks time and resource constraints against operational conditions for current or expected stations. In work are the handling of environmental and other operational constraints, as well as detailed modeling of resources and station operational states. The Ada Program also has the ability to reschedule all or part of the events.

  1. Reading and Readability Affect on E-Learning Success in a Fortune 100 Company: A Correlational Study

    Science.gov (United States)

    Finnegan, Denis Michael Thomas

    2010-01-01

    The purpose of this quantitative correlational study was to examine the relationship between employees' reading skills, E-learning readability, student learning, and student satisfaction. The Tests of Adult Basic Education (TABE) form 10 Level A instrument evaluated student-reading skills. The Flesch-Kincaid Grade Level Index course assessed…

  2. Interfacing and data acquisitioning of creep testing machines

    International Nuclear Information System (INIS)

    Rana, M.A.; Ahmad, Z.; Farooq, M.A.; Ali, L.; Mushtaq, N.

    1998-05-01

    Automation of DSM-6100-CREEP TESTING MACHINES is made by using an IBM PC/XT/AT compatibles along with DAS-16 High Speed Analog I/O board. Creep test parameters namely force, temperature and LVDTs (Linear Variable Differential Transducer) left and right are calibrated. Empirical formula for each parameter is developed to convert data, which is received in the form of counts, into engineering units. LVDT controller module is designed and fabricated to handle two LVDTs for data acquisition of a creep test required for it. (author)

  3. OPMILL - MICRO COMPUTER PROGRAMMING ENVIRONMENT FOR CNC MILLING MACHINES THREE AXIS EQUATION PLOTTING CAPABILITIES

    Science.gov (United States)

    Ray, R. B.

    1994-01-01

    OPMILL is a computer operating system for a Kearney and Trecker milling machine that provides a fast and easy way to program machine part manufacture with an IBM compatible PC. The program gives the machinist an "equation plotter" feature which plots any set of equations that define axis moves (up to three axes simultaneously) and converts those equations to a machine milling program that will move a cutter along a defined path. Other supported functions include: drill with peck, bolt circle, tap, mill arc, quarter circle, circle, circle 2 pass, frame, frame 2 pass, rotary frame, pocket, loop and repeat, and copy blocks. The system includes a tool manager that can handle up to 25 tools and automatically adjusts tool length for each tool. It will display all tool information and stop the milling machine at the appropriate time. Information for the program is entered via a series of menus and compiled to the Kearney and Trecker format. The program can then be loaded into the milling machine, the tool path graphically displayed, and tool change information or the program in Kearney and Trecker format viewed. The program has a complete file handling utility that allows the user to load the program into memory from the hard disk, save the program to the disk with comments, view directories, merge a program on the disk with one in memory, save a portion of a program in memory, and change directories. OPMILL was developed on an IBM PS/2 running DOS 3.3 with 1 MB of RAM. OPMILL was written for an IBM PC or compatible 8088 or 80286 machine connected via an RS-232 port to a Kearney and Trecker Data Mill 700/C Control milling machine. It requires a "D:" drive (fixed-disk or virtual), a browse or text display utility, and an EGA or better display. Users wishing to modify and recompile the source code will also need Turbo BASIC, Turbo C, and Crescent Software's QuickPak for Turbo BASIC. IBM PC and IBM PS/2 are registered trademarks of International Business Machines. Turbo

  4. Optimization of Moving Coil Actuators for Digital Displacement Machines

    DEFF Research Database (Denmark)

    Nørgård, Christian; Bech, Michael Møller; Roemer, Daniel Beck

    2016-01-01

    This paper focuses on deriving an optimal moving coil actuator design, used as force pro-ducing element in hydraulic on/off valves for Digital Displacement machines. Different moving coil actuator geometry topologies (permanent magnet placement and magnetiza-tion direction) are optimized for actu......This paper focuses on deriving an optimal moving coil actuator design, used as force pro-ducing element in hydraulic on/off valves for Digital Displacement machines. Different moving coil actuator geometry topologies (permanent magnet placement and magnetiza-tion direction) are optimized...... for actuating annular seat valves in a digital displacement machine. The optimization objectives are to the minimize the actuator power, the valve flow losses and the height of the actuator. Evaluation of the objective function involves static finite element simulation and simulation of an entire operation...... designs requires approximately 20 W on average and may be realized in 20 mm × Ø 22.5 mm (height × diameter) for a 20 kW pressure chamber. The optimization is carried out using the multi-objective Generalized Differential Evolu-tion optimization algorithm GDE3 which successfully handles constrained multi-objective...

  5. A Systematic Assessment of Google Search Queries and Readability of Online Gynecologic Oncology Patient Education Materials.

    Science.gov (United States)

    Martin, Alexandra; Stewart, J Ryan; Gaskins, Jeremy; Medlin, Erin

    2018-01-20

    The Internet is a major source of health information for gynecologic cancer patients. In this study, we systematically explore common Google search terms related to gynecologic cancer and calculate readability of top resulting websites. We used Google AdWords Keyword Planner to generate a list of commonly searched keywords related to gynecologic oncology, which were sorted into five groups (cervical cancer, ovarian cancer, uterine cancer, vulvar cancer, vaginal cancer) using five patient education websites from sgo.org . Each keyword was Google searched to create a list of top websites. The Python programming language (version 3.5.1) was used to describe frequencies of keywords, top-level domains (TLDs), domains, and readability of top websites using four validated formulae. Of the estimated 1,846,950 monthly searches resulting in 62,227 websites, the most common was cancer.org . The most common TLD was *.com. Most websites were above the eighth-grade reading level recommended by the American Medical Association (AMA) and the National Institute of Health (NIH). The SMOG Index was the most reliable formula. The mean grade level readability for all sites using SMOG was 9.4 ± 2.3, with 23.9% of sites falling at or below the eighth-grade reading level. The first ten results for each Google keyword were easiest to read with results beyond the first page of Google being consistently more difficult. Keywords related to gynecologic malignancies are Google-searched frequently. Most websites are difficult to read without a high school education. This knowledge may help gynecologic oncology providers adequately meet the needs of their patients.

  6. Improving Readability in an Explicit Genre-Based Approach: The Case of an EFL Workplace Context

    Science.gov (United States)

    Albino, Gabriel

    2017-01-01

    The present study investigates how learners of English as a foreign language (EFL) improve the readability of their texts in an explicit genre-based approach that is utilized in an oil and gas exploration workplace in Angola. By drawing on the English for Specific Purposes and Systemic Functional Linguistics genre traditions, the study engages 18…

  7. Privacy Policies for Apps Targeted Toward Youth: Descriptive Analysis of Readability

    Science.gov (United States)

    Das, Gitanjali; Cheung, Cynthia; Nebeker, Camille; Bietz, Matthew

    2018-01-01

    Background Due to the growing availability of consumer information, the protection of personal data is of increasing concern. Objective We assessed readability metrics of privacy policies for apps that are either available to or targeted toward youth to inform strategies to educate and protect youth from unintentional sharing of personal data. Methods We reviewed the 1200 highest ranked apps from the Apple and Google Play Stores and systematically selected apps geared toward youth. After applying exclusion criteria, 99 highly ranked apps geared toward minors remained, 64 of which had a privacy policy. We obtained and analyzed these privacy policies using reading grade level (RGL) as a metric. Policies were further compared as a function of app category (free vs paid; entertainment vs social networking vs utility). Results Analysis of privacy policies for these 64 apps revealed an average RGL of 12.78, which is well above the average reading level (8.0) of adults in the United States. There was also a small but statistically significant difference in word count as a function of app category (entertainment: 2546 words, social networking: 3493 words, and utility: 1038 words; P=.02). Conclusions Although users must agree to privacy policies to access digital tools and products, readability analyses suggest that these agreements are not comprehensible to most adults, let alone youth. We propose that stakeholders, including pediatricians and other health care professionals, play a role in educating youth and their guardians about the use of Web-based services and potential privacy risks, including the unintentional sharing of personal data. PMID:29301737

  8. Readability of arthroscopy-related patient education materials from the American Academy of Orthopaedic Surgeons and Arthroscopy Association of North America Web sites.

    Science.gov (United States)

    Yi, Paul H; Ganta, Abhishek; Hussein, Khalil I; Frank, Rachel M; Jawa, Andrew

    2013-06-01

    We sought to assess the readability levels of arthroscopy-related patient education materials available on the Web sites of the American Academy of Orthopaedic Surgeons (AAOS) and the Arthroscopy Association of North America (AANA). We identified all articles related to arthroscopy available in 2012 from the online patient education libraries of AAOS and AANA. After performing follow-up editing, we assessed each article with the Flesch-Kincaid (FK) readability test. Mean readability levels of the articles from the AAOS Web site and the AANA Web site were compared. We also determined the number of articles with readability levels at or below the eighth-grade level (the average reading ability of the US adult population) and sixth-grade level (the widely recommended level for patient education materials). Intraobserver reliability and interobserver reliability of FK grade assessment were evaluated. A total of 62 articles were reviewed (43 from AAOS and 19 from AANA). The mean overall FK grade level was 10.2 (range, 5.2 to 12). The AAOS articles had a mean FK grade level of 9.6 (range, 5.2 to 12), whereas the AANA articles had a mean FK grade level of 11.4 (range, 8.7 to 12); the difference was significant (P Online patient education materials related to arthroscopy from AAOS and AANA may be written at a level too difficult for a large portion of the patient population to comprehend. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  9. Whole-body Vibration Exposure of Drill Operators in Iron Ore Mines and Role of Machine-Related, Individual, and Rock-Related Factors

    Directory of Open Access Journals (Sweden)

    Dhanjee Kumar Chaudhary

    2015-12-01

    Conclusion: Prevention should include using appropriate machines to handle rock hardness, rock uniaxial compressive strength and density, and seat improvement using ergonomic approaches such as including a suspension system.

  10. Support Vector Machine and Application in Seizure Prediction

    KAUST Repository

    Qiu, Simeng

    2018-04-01

    Nowadays, Machine learning (ML) has been utilized in various kinds of area which across the range from engineering field to business area. In this paper, we first present several kernel machine learning methods of solving classification, regression and clustering problems. These have good performance but also have some limitations. We present examples to each method and analyze the advantages and disadvantages for solving different scenarios. Then we focus on one of the most popular classification methods, Support Vectors Machine (SVM). In addition, we introduce the basic theory, advantages and scenarios of using Support Vector Machine (SVM) deal with classification problems. We also explain a convenient approach of tacking SVM problems which are called Sequential Minimal Optimization (SMO). Moreover, one class SVM can be understood in a different way which is called Support Vector Data Description (SVDD). This is a famous non-linear model problem compared with SVM problems, SVDD can be solved by utilizing Gaussian RBF kernel function combined with SMO. At last, we compared the difference and performance of SVM-SMO implementation and SVM-SVDD implementation. About the application part, we utilized SVM method to handle seizure forecasting in canine epilepsy, after comparing the results from different methods such as random forest, extremely randomized tree, and SVM to classify preictal (pre-seizure) and interictal (interval-seizure) binary data. We draw the conclusion that SVM has the best performance.

  11. Improving DNS security : a measurement-based approach

    NARCIS (Netherlands)

    van Rijswijk-Deij, Roland

    2017-01-01

    The Domain Name System (DNS) is a vital part of the core infrastructure of the Internet. It maps human readable names (such as www.example.com) to machine readable information (such as 93.184.216.34). This thesis studies two aspects of the DNS. First, it studies problems in the DNS Security

  12. Some Considerations about Modern Database Machines

    Directory of Open Access Journals (Sweden)

    Manole VELICANU

    2010-01-01

    Full Text Available Optimizing the two computing resources of any computing system - time and space - has al-ways been one of the priority objectives of any database. A current and effective solution in this respect is the computer database. Optimizing computer applications by means of database machines has been a steady preoccupation of researchers since the late seventies. Several information technologies have revolutionized the present information framework. Out of these, those which have brought a major contribution to the optimization of the databases are: efficient handling of large volumes of data (Data Warehouse, Data Mining, OLAP – On Line Analytical Processing, the improvement of DBMS – Database Management Systems facilities through the integration of the new technologies, the dramatic increase in computing power and the efficient use of it (computer networks, massive parallel computing, Grid Computing and so on. All these information technologies, and others, have favored the resumption of the research on database machines and the obtaining in the last few years of some very good practical results, as far as the optimization of the computing resources is concerned.

  13. ENTREVIS - a Spanish machine-readable text corpus

    DEFF Research Database (Denmark)

    Jensen, Kjær

    1991-01-01

    Præsentation af første halvdel et spansk tekskorpus bestående af samtlige interviews med spaniere i de to ugeskrifter Cambio16 og Tiempo i 1990. Dette korpus er siden suppleret med samtlige interviews i de samme tidsskrifter i 1995. Korpus samlede størrelse: over 1.2 million ord...

  14. Safety mechanism of a lifting machine

    International Nuclear Information System (INIS)

    Blaive, D.; Chopinet, E.

    1985-01-01

    The lifting machine has at least one winch supporting a chain which passes around a chain pulley in a roller block attached to the load. At least one locking mechanism prevents the rotation of the pulley within the block. The locking mechanism can moves between an out-of-operation position and a locking position. A control system includes load sensors associated with the winch sensing the weight of the load acting through the chain. If one part of the chain should break, the load sensors detect this, and the locking mechanism is activated. The invention applies, more particularly, to the handling winches in a fast neutron nuclear power plant [fr

  15. MLitB: machine learning in the browser

    Directory of Open Access Journals (Sweden)

    Edward Meeds

    2015-07-01

    Full Text Available With few exceptions, the field of Machine Learning (ML research has largely ignored the browser as a computational engine. Beyond an educational resource for ML, the browser has vast potential to not only improve the state-of-the-art in ML research, but also, inexpensively and on a massive scale, to bring sophisticated ML learning and prediction to the public at large. This paper introduces MLitB, a prototype ML framework written entirely in Javascript, capable of performing large-scale distributed computing with heterogeneous classes of devices. The development of MLitB has been driven by several underlying objectives whose aim is to make ML learning and usage ubiquitous (by using ubiquitous compute devices, cheap and effortlessly distributed, and collaborative. This is achieved by allowing every internet capable device to run training algorithms and predictive models with no software installation and by saving models in universally readable formats. Our prototype library is capable of training deep neural networks with synchronized, distributed stochastic gradient descent. MLitB offers several important opportunities for novel ML research, including: development of distributed learning algorithms, advancement of web GPU algorithms, novel field and mobile applications, privacy preserving computing, and green grid-computing. MLitB is available as open source software.

  16. PreBIND and Textomy – mining the biomedical literature for protein-protein interactions using a support vector machine

    Directory of Open Access Journals (Sweden)

    Baskin Berivan

    2003-03-01

    Full Text Available Abstract Background The majority of experimentally verified molecular interaction and biological pathway data are present in the unstructured text of biomedical journal articles where they are inaccessible to computational methods. The Biomolecular interaction network database (BIND seeks to capture these data in a machine-readable format. We hypothesized that the formidable task-size of backfilling the database could be reduced by using Support Vector Machine technology to first locate interaction information in the literature. We present an information extraction system that was designed to locate protein-protein interaction data in the literature and present these data to curators and the public for review and entry into BIND. Results Cross-validation estimated the support vector machine's test-set precision, accuracy and recall for classifying abstracts describing interaction information was 92%, 90% and 92% respectively. We estimated that the system would be able to recall up to 60% of all non-high throughput interactions present in another yeast-protein interaction database. Finally, this system was applied to a real-world curation problem and its use was found to reduce the task duration by 70% thus saving 176 days. Conclusions Machine learning methods are useful as tools to direct interaction and pathway database back-filling; however, this potential can only be realized if these techniques are coupled with human review and entry into a factual database such as BIND. The PreBIND system described here is available to the public at http://bind.ca. Current capabilities allow searching for human, mouse and yeast protein-interaction information.

  17. Customer requirement modeling and mapping of numerical control machine

    Directory of Open Access Journals (Sweden)

    Zhongqi Sheng

    2015-10-01

    Full Text Available In order to better obtain information about customer requirement and develop products meeting customer requirement, it is necessary to systematically analyze and handle the customer requirement. This article uses the product service system of numerical control machine as research objective and studies the customer requirement modeling and mapping oriented toward configuration design. It introduces the conception of requirement unit, expounds the customer requirement decomposition rules, and establishes customer requirement model; it builds the house of quality using quality function deployment and confirms the weight of technical feature of product and service; it explores the relevance rules between data using rough set theory, establishes rule database, and solves the target value of technical feature of product. Using economical turning center series numerical control machine as an example, it verifies the rationality of proposed customer requirement model.

  18. A Comprehensive Review and meta-analysis on Applications of Machine Learning Techniques in Intrusion Detection

    Directory of Open Access Journals (Sweden)

    Manojit Chattopadhyay

    2018-05-01

    Full Text Available Securing a machine from various cyber-attacks has been of serious concern for researchers, statutory bodies such as governments, business organizations and users in both wired and wireless media. However, during the last decade, the amount of data handling by any device, particularly servers, has increased exponentially and hence the security of these devices has become a matter of utmost concern. This paper attempts to examine the challenges in the application of machine learning techniques to intrusion detection. We review different inherent issues in defining and applying the machine learning techniques to intrusion detection. We also attempt to identify the best technological solution for changing usage pattern by comparing different machine learning techniques on different datasets and summarizing their performance using various performance metrics. This paper highlights the research challenges and future trends of intrusion detection in dynamic scenarios of intrusion detection problems in diverse network technologies.

  19. Analysis of machining and machine tools

    CERN Document Server

    Liang, Steven Y

    2016-01-01

    This book delivers the fundamental science and mechanics of machining and machine tools by presenting systematic and quantitative knowledge in the form of process mechanics and physics. It gives readers a solid command of machining science and engineering, and familiarizes them with the geometry and functionality requirements of creating parts and components in today’s markets. The authors address traditional machining topics, such as: single and multiple point cutting processes grinding components accuracy and metrology shear stress in cutting cutting temperature and analysis chatter They also address non-traditional machining, such as: electrical discharge machining electrochemical machining laser and electron beam machining A chapter on biomedical machining is also included. This book is appropriate for advanced undergraduate and graduate mechani cal engineering students, manufacturing engineers, and researchers. Each chapter contains examples, exercises and their solutions, and homework problems that re...

  20. Further Issues in Determining the Readability of Self-Report Items: Comment on McHugh and Behar (2009)

    Science.gov (United States)

    Schinka, John A.

    2012-01-01

    Objective: Issues regarding the readability of self-report assessment instruments, methods for establishing the reading ability level of respondents, and guidelines for development of scales designed for marginal readers have been inconsistently addressed in the literature. A recent study by McHugh and Behar (2009) provided new findings relevant…

  1. Readability, suitability, and characteristics of asthma action plans: examination of factors that may impair understanding.

    Science.gov (United States)

    Yin, H Shonna; Gupta, Ruchi S; Tomopoulos, Suzy; Wolf, Michael S; Mendelsohn, Alan L; Antler, Lauren; Sanchez, Dayana C; Lau, Claudia Hillam; Dreyer, Benard P

    2013-01-01

    Recognition of the complexity of asthma management has led to the development of asthma treatment guidelines that include the recommendation that all pediatric asthma patients receive a written asthma action plan. We assessed the readability, suitability, and characteristics of asthma action plans, elements that contribute to the effectiveness of action plan use, particularly for those with limited literacy. This was a descriptive study of 30 asthma action plans (27 state Department of Health (DOH)-endorsed, 3 national action plans endorsed by 6 states). (1) readability (as assessed by Flesch Reading Ease, Flesch-Kincaid, Gunning Fog, Simple Measure of Gobbledygook, Forcast), (2) suitability (Suitability Assessment of Materials [SAM], adequate: ≥ 0.4; unsuitable: typography (30.0%), learning stimulation/motivation (26.7%), and graphics (13.3%). There were no statistically significant differences between the average grade level or SAM score of state DOH developed action plans and those from or adapted from national organizations. Plans varied with respect to terms used, symptoms included, and recommended actions. Specific improvements in asthma action plans could maximize patient and parent understanding of appropriate asthma management and could particularly benefit individuals with limited literacy skills.

  2. Summary of vulnerability related technologies based on machine learning

    Science.gov (United States)

    Zhao, Lei; Chen, Zhihao; Jia, Qiong

    2018-04-01

    As the scale of information system increases by an order of magnitude, the complexity of system software is getting higher. The vulnerability interaction from design, development and deployment to implementation stages greatly increases the risk of the entire information system being attacked successfully. Considering the limitations and lags of the existing mainstream security vulnerability detection techniques, this paper summarizes the development and current status of related technologies based on the machine learning methods applied to deal with massive and irregular data, and handling security vulnerabilities.

  3. Survey of practical application fields of micro-machine and micro-factory technologies in Japan; Nippon ni okeru maikuro machine oyobi maikuro factory gijutsu no jitsuyoka bun`ya chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-01

    As for micro-machine and micro-factory technologies, research and development trends promoted by private companies were surveyed except for national projects. In the field of main technology development by private companies which do not participate in national projects, developments of micro-devices, such as micro-sensor, and micro-actuator, as well as basic technologies, such as machining, assembly, and material technology, are predominant. The applied fields of these aim at electronic industries for measurement and analysis equipment, motorcar sensors, information, communication, and home electric products. While, there are a few research and developments as to micro-robots. Research and developments aiming at application to medical field are widely promoted by private companies. In this field, micro-machining technology for micro-surgery and endoscopes is prospective. There is a photo-forceps technology for handling the micro-parts. However, there are few researches considering the micro-factory. 146 refs., 73 figs., 7 tabs.

  4. Augmented reality with image registration, vision correction and sunlight readability via liquid crystal devices

    OpenAIRE

    Wang, Yu-Jen; Chen, Po-Ju; Liang, Xiao; Lin, Yi-Hsin

    2017-01-01

    Augmented reality (AR), which use computer-aided projected information to augment our sense, has important impact on human life, especially for the elder people. However, there are three major challenges regarding the optical system in the AR system, which are registration, vision correction, and readability under strong ambient light. Here, we solve three challenges simultaneously for the first time using two liquid crystal (LC) lenses and polarizer-free attenuator integrated in optical-see-...

  5. A dynamic simulation to study NET in-vessel handling operations

    International Nuclear Information System (INIS)

    Fung, P.T.F.

    1989-01-01

    The inspection, maintenance and repair of the Next European Torus (NET) fusion machine will require the extensive use of remote handling equipment to minimise the human exposure to the high radiation environment. The use of efficient manipulators will reduce the NET downtime by reducing the preparation time for entry into the controlled area and by performing the task with reasonable area and by performing the task with reasonable dexterity and speed, consistent with safety. A high fidelity simulation is a valuable tool to assist in the manipulator design, operations, trajectory planning, parameter optimisation and system verification. A manipulator simulation package called ASAD was originally developed by Spar for space manipulator applications. It is now being adapted to simulate the in-Vessel HandlingUnit for the NET program. This terestrial version of ASAD has been name ASAD - T. Spar, through the services of the Canadian Fusion Fuels Technology Project, is under contract to the NET program for the performance of this activity. This paper describes the capabillities and underlying assumptions of ASAD - T, aling with description of the simulation development of the NET in-vessel manipulator. (author). 4 refs.; 7 figs

  6. Variations in Textualization: A Cross-Generic and Cross-Disciplinary Study, Implications for Readability of the Academic Discourse

    Science.gov (United States)

    Bonabi, Mina Abbasi; Lotfipour-Saedi, Kazem; Hemmati, Fatemeh; Jafarigohar, Manoochehr

    2018-01-01

    According to discoursal views on language, variations in textualization strategies are always sociocontextually motivated and never happen at random. The textual forms employed in a text, along with many other discoursal and contextual factors, could certainly affect the readability of the text, making it more or less processable for the same…

  7. Does obfuscating excessive CEO pay work? The influence of remuneration report readability on say-on-pay votes

    NARCIS (Netherlands)

    Hooghiemstra, Reggy; Kuang, Yu Flora; Qin, Bo

    2017-01-01

    This paper assesses whether reducing ‘readability’ is an effective obfuscation strategy for influencing the level of shareholder say-on-pay voting dissent in firms with excessive CEO pay. Based on a sample of UK-listed firms, our results indicate that in cases of excessive CEO pay, a less readable

  8. Evaluating the quality and readability of Internet information sources regarding the treatment of swallowing disorders.

    Science.gov (United States)

    O'Connell Ferster, Ashley P; Hu, Amanda

    2017-03-01

    The Internet has become a popular resource for patient education. The information it provides, however, is rarely peer-reviewed, and its quality may be a concern. Since the average American reads at an 8th grade level, the American Medical Association and the National Institutes of Health have recommended that health information be written at a 4th to 6th grade level. We performed a study to assess the quality and readability of online information regarding the treatment of swallowing disorders. A Google search for "swallowing treatment" was conducted. We studied the first 50 websites that appeared on the search engine's results with the use of the DISCERN quality index tool, the Flesch Ease of Reading Score (FRES), and the Flesch-Kincaid Grade Level (FKGL) readability test. DISCERN is a validated 16-item questionnaire used to assess the quality of written health information; FRES and FKGL are used to assess readability. We classified the websites as either patient-targeted or professional-targeted sites, as well as either major or minor. The overall DISCERN score was 1.61 ± 0.61 (range: 1 to 5), the overall FRES was 39.1 ± 19.0 (range: 1 to 100), and the overall FKGL was 11.8 ± 3.4 (range: 3 to 12). As would be expected, patient-targeted websites had significantly higher FRES and significantly lower FKGL scores than did the professional-targeted websites (p = 0.01 and p = 0.04, respectively); there was no significant difference between the two in DISCERN scores. The major websites had significantly higher DISCERN scores than did the minor sites (p = 0.002); there were no significant differences in FRES and FKGL scores. We conclude that online information sources regarding the treatment of swallowing disorders were of suboptimal quality in that information was written at a level too difficult for the average American to easily understand. Also, the patient-targeted websites were written at a lower reading level, and the major websites contained a higher quality

  9. Remote handling equipment for the decommissioning of the Windscale Advanced Gas Cooled Reactor

    International Nuclear Information System (INIS)

    Barker, A.; Birss, I.R.; Fish, G.

    1984-01-01

    A decision to decommission the Windscale Advanced Gas Cooled Reactor was taken shortly after reactor shutdown in 1981. The fuel has now been discharged and the decommissioning programme will last about 10-12 years. The paper describes the programme and objectives and deals with methods of handling and disposing of the radioactive waste material. The main new facility required is a Waste Packaging Building adjacent to the existing reactor in which the waste boxes will be filled, active waste encapsulated in concrete and the boxes cleaned, swabbed and monitored to comply with IAEA transport regulations. The handling machine concept and features are described. The assaying and packaging of the waste material, the control of box movement and the process of concrete encapsulation is described. The paper concludes with a description of the development programme to support the Project. The tasks include a study of cutting techniques, production and control of dust and smoke, viewing and lighting methods, filtration, decontamination and fixing of contamination

  10. IPAD applications to the design, analysis, and/or machining of aerospace structures. [Integrated Program for Aerospace-vehicle Design

    Science.gov (United States)

    Blackburn, C. L.; Dovi, A. R.; Kurtze, W. L.; Storaasli, O. O.

    1981-01-01

    A computer software system for the processing and integration of engineering data and programs, called IPAD (Integrated Programs for Aerospace-Vehicle Design), is described. The ability of the system to relieve the engineer of the mundane task of input data preparation is demonstrated by the application of a prototype system to the design, analysis, and/or machining of three simple structures. Future work to further enhance the system's automated data handling and ability to handle larger and more varied design problems are also presented.

  11. Recommendations for cask features for robotic handling from the Advanced Handling Technology Project

    International Nuclear Information System (INIS)

    Drotning, W.

    1991-02-01

    This report describes the current status and recent progress in the Advanced Handling Technology Project (AHTP) initiated to explore the use of advanced robotic systems and handling technologies to perform automated cask handling operations at radioactive waste handling facilities, and to provide guidance to cask designers on the impact of robotic handling on cask design. Current AHTP tasks have developed system mock-ups to investigate robotic manipulation of impact limiters and cask tiedowns. In addition, cask uprighting and transport, using computer control of a bridge crane and robot, were performed to demonstrate the high speed cask transport operation possible under computer control. All of the current AHTP tasks involving manipulation of impact limiters and tiedowns require robotic operations using a torque wrench. To perform these operations, a pneumatic torque wrench and control system were integrated into the tool suite and control architecture of the gantry robot. The use of captured fasteners is briefly discussed as an area where alternative cask design preferences have resulted from the influence of guidance for robotic handling vs traditional operations experience. Specific robotic handling experiences with these system mock-ups highlight a number of continually recurring design principles: (1) robotic handling feasibility is improved by mechanical designs which emphasize operation with limited dexterity in constrained workspaces; (2) clearances, tolerances, and chamfers must allow for operations under actual conditions with consideration for misalignment and imprecise fixturing; (3) successful robotic handling is enhanced by including design detail in representations for model-based control; (4) robotic handling and overall quality assurance are improved by designs which eliminate the use of loose, disassembled parts. 8 refs., 15 figs

  12. Prototype Vector Machine for Large Scale Semi-Supervised Learning

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Kai; Kwok, James T.; Parvin, Bahram

    2009-04-29

    Practicaldataminingrarelyfalls exactlyinto the supervisedlearning scenario. Rather, the growing amount of unlabeled data poses a big challenge to large-scale semi-supervised learning (SSL). We note that the computationalintensivenessofgraph-based SSLarises largely from the manifold or graph regularization, which in turn lead to large models that are dificult to handle. To alleviate this, we proposed the prototype vector machine (PVM), a highlyscalable,graph-based algorithm for large-scale SSL. Our key innovation is the use of"prototypes vectors" for effcient approximation on both the graph-based regularizer and model representation. The choice of prototypes are grounded upon two important criteria: they not only perform effective low-rank approximation of the kernel matrix, but also span a model suffering the minimum information loss compared with the complete model. We demonstrate encouraging performance and appealing scaling properties of the PVM on a number of machine learning benchmark data sets.

  13. Machine assisted histogram classification

    Science.gov (United States)

    Benyó, B.; Gaspar, C.; Somogyi, P.

    2010-04-01

    LHCb is one of the four major experiments under completion at the Large Hadron Collider (LHC). Monitoring the quality of the acquired data is important, because it allows the verification of the detector performance. Anomalies, such as missing values or unexpected distributions can be indicators of a malfunctioning detector, resulting in poor data quality. Spotting faulty or ageing components can be either done visually using instruments, such as the LHCb Histogram Presenter, or with the help of automated tools. In order to assist detector experts in handling the vast monitoring information resulting from the sheer size of the detector, we propose a graph based clustering tool combined with machine learning algorithm and demonstrate its use by processing histograms representing 2D hitmaps events. We prove the concept by detecting ion feedback events in the LHCb experiment's RICH subdetector.

  14. Machine assisted histogram classification

    Energy Technology Data Exchange (ETDEWEB)

    Benyo, B; Somogyi, P [BME-IIT, H-1117 Budapest, Magyar tudosok koerutja 2. (Hungary); Gaspar, C, E-mail: Peter.Somogyi@cern.c [CERN-PH, CH-1211 Geneve 23 (Switzerland)

    2010-04-01

    LHCb is one of the four major experiments under completion at the Large Hadron Collider (LHC). Monitoring the quality of the acquired data is important, because it allows the verification of the detector performance. Anomalies, such as missing values or unexpected distributions can be indicators of a malfunctioning detector, resulting in poor data quality. Spotting faulty or ageing components can be either done visually using instruments, such as the LHCb Histogram Presenter, or with the help of automated tools. In order to assist detector experts in handling the vast monitoring information resulting from the sheer size of the detector, we propose a graph based clustering tool combined with machine learning algorithm and demonstrate its use by processing histograms representing 2D hitmaps events. We prove the concept by detecting ion feedback events in the LHCb experiment's RICH subdetector.

  15. Developing a Practical Readability Tool for Assessing Written Oral Health Promotion Material for People with Low Literacy

    Science.gov (United States)

    de Silva, Andrea M.; Martin-Kerry, Jacqueline M.; Van, Kelly; Hegde, Shalika; Heilbrunn-Lang, Adina

    2017-01-01

    Objective: Oral health promotion resources need to be simple, useful, accessible and understandable to be effective. The importance of this is magnified for population groups who are at increased risk of poor oral health, have low literacy or language barriers. Consultation with health service providers identified the need for a readability tool…

  16. Molecular computing: paths to chemical Turing machines.

    Science.gov (United States)

    Varghese, Shaji; Elemans, Johannes A A W; Rowan, Alan E; Nolte, Roeland J M

    2015-11-13

    To comply with the rapidly increasing demand of information storage and processing, new strategies for computing are needed. The idea of molecular computing, where basic computations occur through molecular, supramolecular, or biomolecular approaches, rather than electronically, has long captivated researchers. The prospects of using molecules and (bio)macromolecules for computing is not without precedent. Nature is replete with examples where the handling and storing of data occurs with high efficiencies, low energy costs, and high-density information encoding. The design and assembly of computers that function according to the universal approaches of computing, such as those in a Turing machine, might be realized in a chemical way in the future; this is both fascinating and extremely challenging. In this perspective, we highlight molecular and (bio)macromolecular systems that have been designed and synthesized so far with the objective of using them for computing purposes. We also present a blueprint of a molecular Turing machine, which is based on a catalytic device that glides along a polymer tape and, while moving, prints binary information on this tape in the form of oxygen atoms.

  17. Machine learning methods without tears: a primer for ecologists.

    Science.gov (United States)

    Olden, Julian D; Lawler, Joshua J; Poff, N LeRoy

    2008-06-01

    Machine learning methods, a family of statistical techniques with origins in the field of artificial intelligence, are recognized as holding great promise for the advancement of understanding and prediction about ecological phenomena. These modeling techniques are flexible enough to handle complex problems with multiple interacting elements and typically outcompete traditional approaches (e.g., generalized linear models), making them ideal for modeling ecological systems. Despite their inherent advantages, a review of the literature reveals only a modest use of these approaches in ecology as compared to other disciplines. One potential explanation for this lack of interest is that machine learning techniques do not fall neatly into the class of statistical modeling approaches with which most ecologists are familiar. In this paper, we provide an introduction to three machine learning approaches that can be broadly used by ecologists: classification and regression trees, artificial neural networks, and evolutionary computation. For each approach, we provide a brief background to the methodology, give examples of its application in ecology, describe model development and implementation, discuss strengths and weaknesses, explore the availability of statistical software, and provide an illustrative example. Although the ecological application of machine learning approaches has increased, there remains considerable skepticism with respect to the role of these techniques in ecology. Our review encourages a greater understanding of machin learning approaches and promotes their future application and utilization, while also providing a basis from which ecologists can make informed decisions about whether to select or avoid these approaches in their future modeling endeavors.

  18. GELATIO: a general framework for modular digital analysis of high-purity Ge detector signals

    International Nuclear Information System (INIS)

    Agostini, M; Pandola, L; Zavarise, P; Volynets, O

    2011-01-01

    GELATIO is a new software framework for advanced data analysis and digital signal processing developed for the GERDA neutrinoless double beta decay experiment. The framework is tailored to handle the full analysis flow of signals recorded by high purity Ge detectors and photo-multipliers from the veto counters. It is designed to support a multi-channel modular and flexible analysis, widely customizable by the user either via human-readable initialization files or via a graphical interface. The framework organizes the data into a multi-level structure, from the raw data up to the condensed analysis parameters, and includes tools and utilities to handle the data stream between the different levels. GELATIO is implemented in C++. It relies upon ROOT and its extension TAM, which provides compatibility with PROOF, enabling the software to run in parallel on clusters of computers or many-core machines. It was tested on different platforms and benchmarked in several GERDA-related applications. A stable version is presently available for the GERDA Collaboration and it is used to provide the reference analysis of the experiment data.

  19. GELATIO: a general framework for modular digital analysis of high-purity Ge detector signals

    Science.gov (United States)

    Agostini, M.; Pandola, L.; Zavarise, P.; Volynets, O.

    2011-08-01

    GELATIO is a new software framework for advanced data analysis and digital signal processing developed for the GERDA neutrinoless double beta decay experiment. The framework is tailored to handle the full analysis flow of signals recorded by high purity Ge detectors and photo-multipliers from the veto counters. It is designed to support a multi-channel modular and flexible analysis, widely customizable by the user either via human-readable initialization files or via a graphical interface. The framework organizes the data into a multi-level structure, from the raw data up to the condensed analysis parameters, and includes tools and utilities to handle the data stream between the different levels. GELATIO is implemented in C++. It relies upon ROOT and its extension TAM, which provides compatibility with PROOF, enabling the software to run in parallel on clusters of computers or many-core machines. It was tested on different platforms and benchmarked in several GERDA-related applications. A stable version is presently available for the GERDA Collaboration and it is used to provide the reference analysis of the experiment data.

  20. Remotely controlled inspection and handling systems for decommissioning tasks in nuclear facilities

    International Nuclear Information System (INIS)

    Schreck, G.; Bach, W.; Haferkamp, H.

    1993-01-01

    The Institut fur Werkstoffkunde at the University of Hanover has recently developed three remotely controlled systems for different underwater inspection and dismantling tasks. ODIN I is a tool guiding device, particularly being designed for the dismantling of the steam dryer housing of the KRB A power plant at Gundremmingen, Germany. After being approved by the licencing organization TUEV Bayern, hot operation started in November 1992. The seven axes remotely controlled handling system ZEUS, consisting of a three translatory axes guiding machine and a tool handling device with four rotatory axes, has been developed for the demonstration of underwater plasma arc cutting of spherical metallic components with great wall thicknesses. A specially designed twin sensor system and a modular torch, exchanged by means of a remote controlled tool changing device, will be used for different complex cutting tasks. FAUST, an autonomous, freediving underwater vehicle, was designed for complex inspection, maintenance and dismantling tasks. It is equipped with two video cameras, an ultrasonic and a radiologic sensor and a small plasma torch. A gripper and a subsidiary vehicle for inspection may be attached. (author)

  1. An online readability analysis of pathology-related patient education articles: an opportunity for pathologists to educate patients.

    Science.gov (United States)

    Prabhu, Arpan V; Kim, Christopher; Crihalmeanu, Tudor; Hansberry, David R; Agarwal, Nitin; DeFrances, Marie C; Trejo Bittar, Humberto E

    2017-07-01

    Information for patients regarding their clinical conditions and treatment options is widely available online. The American Medical Association and National Institutes of Health recommend that online patient-oriented materials be written at no higher than a seventh-grade reading level to ensure full comprehension by the average American. This study sought to determine whether online patient-oriented materials explaining common pathology procedures are written at appropriate reading levels. Ten pathology procedures that patients would likely research were queried into Google search, and plain text from the first 10 Web sites containing patient education materials for each procedure was analyzed using 10 validated readability scales. We determined mean reading levels of materials grouped by readability scale, procedure, and Web site domain, the overall average reading level of all resources, and popular Web site domains. One hundred Web sites were accessed; one was omitted for short length (pathology-related patient education materials exceeded those recommended by national health literacy guidelines. These patient education materials should be revised to help patients fully understand them. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Evolutionary and Swarm computing for the Semantic Web

    NARCIS (Netherlands)

    Guéret, C.; Schlobach, S.; Dentler, K.; Schut, M.; Eiben, G.

    2012-01-01

    The Semantic Web has become a dynamic and enormous network of typed links between data sets stored on different machines. These data sets are machine readable and unambiguously interpretable, thanks to their underlying standard representation languages. The expressiveness and flexibility of the

  3. Evolutionary and Swarm Computing for the Semantic Web

    NARCIS (Netherlands)

    Guéret, Christophe

    2015-01-01

    The Semantic Web has become a dynamic and enormous network of typed links between data sets stored on different machines. These data sets are machine readable and unambiguously interpretable, thanks to their underlying standard representation languages. The expressiveness and flexibility of the

  4. Machine rates for selected forest harvesting machines

    Science.gov (United States)

    R.W. Brinker; J. Kinard; Robert Rummer; B. Lanford

    2002-01-01

    Very little new literature has been published on the subject of machine rates and machine cost analysis since 1989 when the Alabama Agricultural Experiment Station Circular 296, Machine Rates for Selected Forest Harvesting Machines, was originally published. Many machines discussed in the original publication have undergone substantial changes in various aspects, not...

  5. LHCb: Machine assisted histogram classification

    CERN Multimedia

    Somogyi, P; Gaspar, C

    2009-01-01

    LHCb is one of the four major experiments under completion at the Large Hadron Collider (LHC). Monitoring the quality of the acquired data is important, because it allows the verification of the detector performance. Anomalies, such as missing values or unexpected distributions can be indicators of a malfunctioning detector, resulting in poor data quality. Spotting faulty components can be either done visually using instruments such as the LHCb Histogram Presenter, or by automated tools. In order to assist detector experts in handling the vast monitoring information resulting from the sheer size of the detector, a graph-theoretic based clustering tool, combined with machine learning algorithms is proposed and demonstrated by processing histograms representing 2D event hitmaps. The concept is proven by detecting ion feedback events in the LHCb RICH subdetector.

  6. Readability and Comprehension of the Geriatric Depression Scale and PROMIS® Physical Function Items in Older African Americans and Latinos.

    Science.gov (United States)

    Paz, Sylvia H; Jones, Loretta; Calderón, José L; Hays, Ron D

    2017-02-01

    Depression and physical function are particularly important health domains for the elderly. The Geriatric Depression Scale (GDS) and the Patient-Reported Outcomes Measurement Information System (PROMIS ® ) physical function item bank are two surveys commonly used to measure these domains. It is unclear if these two instruments adequately measure these aspects of health in minority elderly. The aim of this study was to estimate the readability of the GDS and PROMIS ® physical function items and to assess their comprehensibility using a sample of African American and Latino elderly. Readability was estimated using the Flesch-Kincaid and Flesch Reading Ease (FRE) formulae for English versions, and a Spanish adaptation of the FRE formula for the Spanish versions. Comprehension of the GDS and PROMIS ® items by minority elderly was evaluated with 30 cognitive interviews. Readability estimates of a number of items in English and Spanish of the GDS and PROMIS ® physical functioning items exceed the U.S. recommended 5th-grade threshold for vulnerable populations, or were rated as 'fairly difficult', 'difficult', or 'very difficult' to read. Cognitive interviews revealed that many participants felt that more than the two (yes/no) GDS response options were needed to answer the questions. Wording of several PROMIS ® items was considered confusing, and interpreting responses was problematic because they were based on using physical aids. Problems with item wording and response options of the GDS and PROMIS ® physical function items may reduce reliability and validity of measurement when used with minority elderly.

  7. Structural analysis of fuel handling systems

    Energy Technology Data Exchange (ETDEWEB)

    Lee, L S.S. [Atomic Energy of Canada Ltd., Mississauga, ON (Canada)

    1997-12-31

    The purpose of this paper has three aspects: (i) to review `why` and `what` types of structural analysis, testing and report are required for the fuel handling systems according to the codes, or needed for design of a product, (ii) to review the input requirements for analysis and the analysis procedures, and (iii) to improve the communication between the analysis and other elements of the product cycle. The required or needed types of analysis and report may be categorized into three major groups: (i) Certified Stress Reports for design by analysis, (ii) Design Reports not required for certification and registration, but are still required by codes, and (iii) Design Calculations required by codes or needed for design. Input requirements for structural analysis include: design, code classification, loadings, and jurisdictionary boundary. Examples of structural analysis for the fueling machine head and support structure are given. For improving communication between the structural analysis and the other elements of the product cycle, some areas in the specification of design requirements and load rating are discussed. (author). 6 refs., 1 tab., 4 figs.

  8. Structural analysis of fuel handling systems

    International Nuclear Information System (INIS)

    Lee, L.S.S.

    1996-01-01

    The purpose of this paper has three aspects: (i) to review 'why' and 'what' types of structural analysis, testing and report are required for the fuel handling systems according to the codes, or needed for design of a product, (ii) to review the input requirements for analysis and the analysis procedures, and (iii) to improve the communication between the analysis and other elements of the product cycle. The required or needed types of analysis and report may be categorized into three major groups: (i) Certified Stress Reports for design by analysis, (ii) Design Reports not required for certification and registration, but are still required by codes, and (iii) Design Calculations required by codes or needed for design. Input requirements for structural analysis include: design, code classification, loadings, and jurisdictionary boundary. Examples of structural analysis for the fueling machine head and support structure are given. For improving communication between the structural analysis and the other elements of the product cycle, some areas in the specification of design requirements and load rating are discussed. (author). 6 refs., 1 tab., 4 figs

  9. Robotic Irradiated Sample Handling Concept Design in Reactor TRIGA PUSPATI using Simulation Software

    International Nuclear Information System (INIS)

    Mohd Khairulezwan Abdul Manan; Mohd Sabri Minhat; Ridzuan Abdul Mutalib; Zareen Khan Abdul Jalil Khan; Nurfarhana Ayuni Joha

    2015-01-01

    This paper introduces the concept design of an Robotic Irradiated Sample Handling Machine using graphical software application, designed as a general, flexible and open platform to work on robotics. Webots has proven to be a useful tool in many fields of robotics, such as manipulator programming, mobile robots control (wheeled, sub-aquatic and walking robots), distance computation, sensor simulation, collision detection, motion planning and so on. Webots is used as the common interface for all the applications. Some practical cases and application for this concept design are illustrated on the paper to present the possibilities of this simulation software. (author)

  10. WALS: A sensor-based robotic system for handling nuclear materials

    International Nuclear Information System (INIS)

    Drotning, W.; Kimberly, H.; Wapman, W.

    1997-01-01

    An automated system is being developed for handling large payloads of radioactive nuclear materials in an analytical laboratory. The system uses machine vision and force/torque sensing to provide sensor-based control of the automation system to enhance system safety, flexibility, and robustness and achieve easy remote operation. The automation system also controls the operation of the laboratory measurement systems and the coordination of them with the robotic system. Particular attention has been given to system design features and analytical methods that provide an enhanced level of operational safety. Independent mechanical gripper interlock and too release mechanisms were designed to prevent payload mishandling. An extensive failure modes and effects analysis (FMEA) of the automation system was developed as a safety design analysis tool

  11. How Readability Factors Are Differentially Associated with Performance for Students of Different Backgrounds When Solving Mathematics Word Problems

    Science.gov (United States)

    Walkington, Candace; Clinton, Virginia; Shivraj, Pooja

    2018-01-01

    The link between reading and mathematics achievement is well known, and an important question is whether readability factors in mathematics problems are differentially impacting student groups. Using 20 years of data from the National Assessment of Educational Progress and the Trends in International Mathematics and Science Study, we examine how…

  12. Fuel handling system of Indian 500 MWe PHWR-evolution and innovations

    International Nuclear Information System (INIS)

    Sanatkumar, A.; Jit, I.; Muralidhar, G.

    1996-01-01

    India has gained rich experience in design, manufacture, testing, operation and maintenance of the Fuel Handling System of CANDU type PHWRs. When design and layout of the first 500 MWe PHWR was being evolved, it was possible for us to introduce many special and innovative features in the Fuel Handling System which are friendly for operations and maintenance personnel. Some of these are: Simple, robust and modular mechanisms for ease of maintenance; Shorter turnaround time for refuelling a channel by introduction of transit equipment between the Fuelling Machine (FM) Head and light water equipment; Optimised layout to transport spent fuel in straight and short path and also to facilitate direct wheeling out of the FM Head from the Reactor Building to the Service Building; Provision to operate the FM Head even when the Primary Heat Transport (PHT) System is open for maintenance; Control-console engineered for carrying out refuelling operations in the sitting position; and, Dedicated calibration and maintenance facility to facilitate quick replacement of the FM Head as a single unit. The above special features have been described in this paper. (author). 7 figs

  13. Fuel handling system of Indian 500 MWe PHWR-evolution and innovations

    Energy Technology Data Exchange (ETDEWEB)

    Sanatkumar, A; Jit, I; Muralidhar, G [Nuclear Power Corporation of India Ltd., Mumbai (India)

    1997-12-31

    India has gained rich experience in design, manufacture, testing, operation and maintenance of the Fuel Handling System of CANDU type PHWRs. When design and layout of the first 500 MWe PHWR was being evolved, it was possible for us to introduce many special and innovative features in the Fuel Handling System which are friendly for operations and maintenance personnel. Some of these are: Simple, robust and modular mechanisms for ease of maintenance; Shorter turnaround time for refuelling a channel by introduction of transit equipment between the Fuelling Machine (FM) Head and light water equipment; Optimised layout to transport spent fuel in straight and short path and also to facilitate direct wheeling out of the FM Head from the Reactor Building to the Service Building; Provision to operate the FM Head even when the Primary Heat Transport (PHT) System is open for maintenance; Control-console engineered for carrying out refuelling operations in the sitting position; and, Dedicated calibration and maintenance facility to facilitate quick replacement of the FM Head as a single unit. The above special features have been described in this paper. (author). 7 figs.

  14. Full scale tests on remote handled FFTF fuel assembly waste handling and packaging

    International Nuclear Information System (INIS)

    Allen, C.R.; Cash, R.J.; Dawson, S.A.; Strode, J.N.

    1986-01-01

    Handling and packaging of remote handled, high activity solid waste fuel assembly hardware components from spent FFTF reactor fuel assemblies have been evaluated using full scale components. The demonstration was performed using FFTF fuel assembly components and simulated components which were handled remotely using electromechanical manipulators, shielding walls, master slave manipulators, specially designed grapples, and remote TV viewing. The testing and evaluation included handling, packaging for current and conceptual shipping containers, and the effects of volume reduction on packing efficiency and shielding requirements. Effects of waste segregation into transuranic (TRU) and non-transuranic fractions also are discussed

  15. The Relationship between Readability Level of Mississippi's Middle Schools' Websites and Seventh Grade Language Arts MCT2 Scores

    Science.gov (United States)

    Pickard, Anna Marlene Graves

    2011-01-01

    Today's educators face the unprecedented challenge of increasing achievement for all students. One response has been to increase and improve parent involvement and school-to-home communication through the use of school websites. The quantitative section of this study analyzed the readability grade level of the website as it relates to state test…

  16. A report on the collection of data relevant to the Canadian National Uranium Tailings Program

    International Nuclear Information System (INIS)

    Smith, A.

    1984-10-01

    In December of 1983, Systemhouse Ltd. was awarded a contract to collect data relevant to the Canadian National Uranium Tailings Program and to convert it into a machine readable format. The work was carried out in four phases, namely, data identification, data collection, data transcription/conversion and data verification. The main priority was to identify as much relevant data as possible. The identified data was priorized against a predefined criteria established in conjunction with the project scientific authority. A total of 428 studies were identified as being relevant. Data from 19 of these were converted to machine-readable format, giving information on 2398 samples from 78 boreholes

  17. Interdisciplinary Approach to Tool-Handle Design Based on Medical Imaging

    Directory of Open Access Journals (Sweden)

    G. Harih

    2013-01-01

    Full Text Available Products are becoming increasingly complex; therefore, designers are faced with a challenging task to incorporate new functionality, higher performance, and optimal shape design. Traditional user-centered design techniques such as designing with anthropometric data do not incorporate enough subject data to design products with optimal shape for best fit to the target population. To overcome these limitations, we present an interdisciplinary approach with medical imaging. The use of this approach is being presented on the development of an optimal sized and shaped tool handle where the hand is imaged using magnetic resonance imaging machine. The obtained images of the hand are reconstructed and imported into computer-aided design software, where optimal shape of the handle is obtained with Boolean operations. Methods can be used to develop fully customized products with optimal shape to provide best fit to the target population. This increases subjective comfort rating, performance and can prevent acute and cumulative trauma disorders. Provided methods are especially suited for products where high stresses and exceptional performance is expected (high performance tools, professional sports, and military equipment, etc.. With the use of these interdisciplinary methods, the value of the product is increased, which also increases the competitiveness of the product on the market.

  18. A Collaboration Model for Community-Based Software Development with Social Machines

    Directory of Open Access Journals (Sweden)

    Dave Murray-Rust

    2016-02-01

    Full Text Available Crowdsourcing is generally used for tasks with minimal coordination, providing limited support for dynamic reconfiguration. Modern systems, exemplified by social ma chines, are subject to continual flux in both the client and development communities and their needs. To support crowdsourcing of open-ended development, systems must dynamically integrate human creativity with machine support. While workflows can be u sed to handle structured, predictable processes, they are less suitable for social machine development and its attendant uncertainty. We present models and techniques for coordination of human workers in crowdsourced software development environments. We combine the Social Compute Unit—a model of ad-hoc human worker teams—with versatile coordination protocols expressed in the Lightweight Social Calculus. This allows us to combine coordination and quality constraints with dynamic assessments of end-user desires, dynamically discovering and applying development protocols.

  19. Replacement Condition Detection of Railway Point Machines Using an Electric Current Sensor.

    Science.gov (United States)

    Sa, Jaewon; Choi, Younchang; Chung, Yongwha; Kim, Hee-Young; Park, Daihee; Yoon, Sukhan

    2017-01-29

    Detecting replacement conditions of railway point machines is important to simultaneously satisfy the budget-limit and train-safety requirements. In this study, we consider classification of the subtle differences in the aging effect-using electric current shape analysis-for the purpose of replacement condition detection of railway point machines. After analyzing the shapes of after-replacement data and then labeling the shapes of each before-replacement data, we can derive the criteria that can handle the subtle differences between "does-not-need-to-be-replaced" and "needs-to-be-replaced" shapes. On the basis of the experimental results with in-field replacement data, we confirmed that the proposed method could detect the replacement conditions with acceptable accuracy, as well as provide visual interpretability of the criteria used for the time-series classification.

  20. [A new machinability test machine and the machinability of composite resins for core built-up].

    Science.gov (United States)

    Iwasaki, N

    2001-06-01

    A new machinability test machine especially for dental materials was contrived. The purpose of this study was to evaluate the effects of grinding conditions on machinability of core built-up resins using this machine, and to confirm the relationship between machinability and other properties of composite resins. The experimental machinability test machine consisted of a dental air-turbine handpiece, a control weight unit, a driving unit of the stage fixing the test specimen, and so on. The machinability was evaluated as the change in volume after grinding using a diamond point. Five kinds of core built-up resins and human teeth were used in this study. The machinabilities of these composite resins increased with an increasing load during grinding, and decreased with repeated grinding. There was no obvious correlation between the machinability and Vickers' hardness; however, a negative correlation was observed between machinability and scratch width.

  1. 以適讀性公式挑選英文讀本之探究 How to Use Readability Formulas to Access and Select English Reading Materials

    Directory of Open Access Journals (Sweden)

    Hai-Hon Chen

    2012-12-01

    Full Text Available 本研究旨在說明常用的適讀性公式。以三本英文讀本The empty pot(670字)、Smoky night(1,267字)、和Sarah, plain and tall(3,158字)為研究對象,以Microsoft Word文書處理軟體的可讀性公式、網路免費適讀工具的適讀公式、以及手算,進行讀物適讀年級程度的計算;其次,比較同一讀本在不同的適讀軟體公式或手算所得的結果是否相同?研究結果指出: 1. 三本讀物The empty pot字數最少、適合美國五年級程度閱讀,Sarah, plain and tall字數最多、適合美國三、四年級閱讀程度,Smoky night適合美國三年級程度。 2. Microsoft Word文書處理的可讀性公式統計,可取得文本全文的適讀分數及年級程度,簡易方便使用。 3. 適讀性公式會依公式採用分析比較的因素不同,結果稍有差異,但每本書的難度排列順序或適讀年級的順序是相同的。 4. 適讀性公式的決定因素相同,不論是手算的Fry圖或使用電腦工具的Flesch-Kincaid,所得的年級程度相同。文中並提出臺灣教師、圖書教師或館員應用適讀性公式為臺灣學生選擇英語讀物的建議。The purpose of this study was to describe the most common readability formulas. Three children’s books, The empty pot (670 words, Smoky night (1,267 words, and Sarah, plain and tall (3,158 words were used as the subjects to calculate the numerical or grade-level score. The study also focused on comparing readability formulas that were calculated using different methods: with a tool embedded in a Microsoft Word processing program, with Free Text Readability Consensus Calculator tools found on the web, and by hand. Results were presented as follows: 1. The empty pot that was the least words got a fifth-grade level, Sarah, plain and tall that was the most words got a third-fourth grade level, Smoky night a third grade level. 2. Readability formula embedded in a Microsoft

  2. Ergonomic material-handling device

    Science.gov (United States)

    Barsnick, Lance E.; Zalk, David M.; Perry, Catherine M.; Biggs, Terry; Tageson, Robert E.

    2004-08-24

    A hand-held ergonomic material-handling device capable of moving heavy objects, such as large waste containers and other large objects requiring mechanical assistance. The ergonomic material-handling device can be used with neutral postures of the back, shoulders, wrists and knees, thereby reducing potential injury to the user. The device involves two key features: 1) gives the user the ability to adjust the height of the handles of the device to ergonomically fit the needs of the user's back, wrists and shoulders; and 2) has a rounded handlebar shape, as well as the size and configuration of the handles which keep the user's wrists in a neutral posture during manipulation of the device.

  3. Evolution of on-power fuelling machines on Canadian natural uranium power reactors

    International Nuclear Information System (INIS)

    Isaac, P.

    1984-10-01

    The evolution of the on-power fuel changing process and fuelling machines on CANDU heavy-water pressure tube power reactors from the first nuclear power demonstration plant, 22 MWe NPD, to the latest plants now in design and development is described. The high availability of CANDU's is largely dependent on on-power fuelling. The on-power fuelling performance record of the 16 operating CANDU reactors, covering a 22 year period since the first plant became operational, is given. This shows that on-power fuel changing with light (unshielded), highly mobile and readily maintainable fuelling machines has been a success. The fuelling machines have contributed very little to the incapabilities of the plants and have been a key factor in placing CANDUs in the top ten list of world performance. Although fuel handling technology has reached a degree of maturity, refinements are continuing. A new single-ended fuel changing concept for horizontal reactors under development is described. This has the potential for reducing capital and operating costs for small reactors and increasing the fuelling capability of possible large reactors of the future

  4. The history, development and application of a uniformly applied load wide plate testing machine

    International Nuclear Information System (INIS)

    Quirk, A.; Bevitt, E.

    1989-01-01

    The paper describes early attempts to use a rigid end wide plate testing machine to investigate the behaviour of centre cracked flat plates. Confusing and inconsistent results arising from the above tests lead to a detailed investigation of the loading characteristics of rigid end machines in general and the difficulties which can arise in the interpretation of data obtained by the use of such machines. In order to overcome the above difficulties which stem largely from uneven load distribution, a versatile testing machine was designed which by use of cheap and easily obtainable components allows the application of a uniformly distributed applied load to a centre cracked test plate. The machine which was commissioned in its original form in 1975 was initially capable of testing plate of 820 mm width and 25 or 48 mm thickness up to maximum stress levels of 488 or 254 MPa respectively. The ease of adaptability of the machine has since permitted its capacity to be increased to handle plate up to 2032 mm wide and 76 mm thickness and by use of double-banked hydraulic jacks stress levels up to 350 MPa can be achieved on plate of these dimensions. The configuration of the machine allows adequate access for strain gauging, crack tip observation and measurements, and temperature control, tests having been conducted in the temperature range -40 0 C to 290 0 C. Advantages and potential for further development of the machine are given together with details of two of a number of fracture studies which have been conducted since its commissioning. (orig.)

  5. Determining the efficacy of the chronic disease self-management programme and readability of 'living a healthy life with chronic conditions' in a New Zealand setting.

    Science.gov (United States)

    Cheng, J J-Y; Arenhold, F; Braakhuis, A J

    2016-11-01

    Self-management programmes are an increasingly popular way of treating chronic diseases. This study aims to determine the efficacy of the Stanford Chronic Disease Self-Management Programme (CDSMP) in a New Zealand context by assessing course outcomes and readability of the accompanying reference guide Living a Healthy Life with Chronic Conditions, 4th Edition. This is a cross-sectional pre-post study conducted in Auckland between August 2009 and September 2015, using CDSMP participants' baseline and follow-up Health Education Intervention Questionnaire (heiQ TM ) data. Readability of the guide was assessed using the Gunning Fog Index, Coleman Liau, Flesch Reading Ease, Flesch Kincaid Grade Level and Simplified Measure of Gobbledygook scores. Significant evidence of improvement (P ≤ 0.001) was observed in seven of the eight domains measured by the heiQ TM (Deakin University, Centre for Population Health Research, Melbourne, Vic., Australia). The greatest improvements were seen in skill and technique acquisition (mean change score 0.25, P ≤ 0.001) and self-monitoring and insight (0.18, P ≤ 0.001). There was little evidence of improvement in health service navigation (0.04, P = 0.17). Readability analyses indicate that a person needs to be reading at a minimum of U.S. 8th grade level in order to understand the text, and possibly up to 11th grade. The CDSMP is effective for improving patient self-efficacy in the New Zealand setting. However, adaptation of the programme to support better health service navigation is warranted. The readability of the reference guide is not suitable for this setting and requires further improvement. © 2016 Royal Australasian College of Physicians.

  6. Evaluating ITER remote handling middleware concepts

    International Nuclear Information System (INIS)

    Koning, J.F.; Heemskerk, C.J.M.; Schoen, P.; Smedinga, D.; Boode, A.H.; Hamilton, D.T.

    2013-01-01

    Highlights: ► Remote Handling Study Centre: middleware system setup and modules built. ► Aligning to ITER RH Control System Layout: prototype of database, VR and simulator. ► OpenSplice DDS, ZeroC ICE messaging and object oriented middlewares reviewed. ► Windows network latency found problematic for semi-realtime control over the network. -- Abstract: Remote maintenance activities in ITER will be performed by a unique set of hardware systems, supported by an extensive software kit. A layer of middleware will manage and control a complex set of interconnections between teams of operators, hardware devices in various operating theatres, and databases managing tool and task logistics. The middleware is driven by constraints on amounts and timing of data like real-time control loops, camera images, and database access. The Remote Handling Study Centre (RHSC), located at FOM institute DIFFER, has a 4-operator work cell in an ITER relevant RH Control Room setup which connects to a virtual hot cell back-end. The centre is developing and testing flexible integration of the Control Room components, resulting in proof-of-concept tests of this middleware layer. SW components studied include generic human-machine interface software, a prototype of a RH operations management system, and a distributed virtual reality system supporting multi-screen, multi-actor, and multiple independent views. Real-time rigid body dynamics and contact interaction simulation software supports simulation of structural deformation, “augmented reality” operations and operator training. The paper presents generic requirements and conceptual design of middleware components and Operations Management System in the context of a RH Control Room work cell. The simulation software is analyzed for real-time performance and it is argued that it is critical for middleware to have complete control over the physical network to be able to guarantee bandwidth and latency to the components

  7. Evaluating ITER remote handling middleware concepts

    Energy Technology Data Exchange (ETDEWEB)

    Koning, J.F., E-mail: j.f.koning@differ.nl [FOM Institute DIFFER, Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster and ITER-NL, PO Box 1207, 3430 BE Nieuwegein (Netherlands); Heemskerk, C.J.M.; Schoen, P.; Smedinga, D. [Heemskerk Innovative Technology, Noordwijk (Netherlands); Boode, A.H. [University of Applied Sciences InHolland, Alkmaar (Netherlands); Hamilton, D.T. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France)

    2013-10-15

    Highlights: ► Remote Handling Study Centre: middleware system setup and modules built. ► Aligning to ITER RH Control System Layout: prototype of database, VR and simulator. ► OpenSplice DDS, ZeroC ICE messaging and object oriented middlewares reviewed. ► Windows network latency found problematic for semi-realtime control over the network. -- Abstract: Remote maintenance activities in ITER will be performed by a unique set of hardware systems, supported by an extensive software kit. A layer of middleware will manage and control a complex set of interconnections between teams of operators, hardware devices in various operating theatres, and databases managing tool and task logistics. The middleware is driven by constraints on amounts and timing of data like real-time control loops, camera images, and database access. The Remote Handling Study Centre (RHSC), located at FOM institute DIFFER, has a 4-operator work cell in an ITER relevant RH Control Room setup which connects to a virtual hot cell back-end. The centre is developing and testing flexible integration of the Control Room components, resulting in proof-of-concept tests of this middleware layer. SW components studied include generic human-machine interface software, a prototype of a RH operations management system, and a distributed virtual reality system supporting multi-screen, multi-actor, and multiple independent views. Real-time rigid body dynamics and contact interaction simulation software supports simulation of structural deformation, “augmented reality” operations and operator training. The paper presents generic requirements and conceptual design of middleware components and Operations Management System in the context of a RH Control Room work cell. The simulation software is analyzed for real-time performance and it is argued that it is critical for middleware to have complete control over the physical network to be able to guarantee bandwidth and latency to the components.

  8. Applicability of Machine-Learning Enabled LIBS in Post Irradiation Nuclear Forensic Analysis of High Level Waste

    International Nuclear Information System (INIS)

    Onkongi, J.; Maina, D.; Angeyo, H.K.

    2017-01-01

    Nuclear Forensics seeks Information to determine; Chemical Composition, Routes of transit, Origin (Provenance) and Intended use. Post Irradiation/Post detonation NF In a post-detonation event could you get clues/signatures from glass debris, minute sample sizes? Nuclear Forensic Technique Should be State-of -the art that is Rapid, Non-invasive, Remote ability and Non-destructive. Laser Induced Breakdown Spectroscopy (LIBS) unlike other Analytic Techniques that require tedious sample preparations such as Dissolution, digestion & matrix removal, which generate additional nuclear wastes that require proper Procedures for handling, storage & ultimate disposal, LIBS overcomes these limitations. Utility of Machine Learning Techniques employed include; Artificial Neural Networks, ANN (Regression/Modelling), Principal component Analysis, PCA (Classification) and Support Vector Machine SVM (Comparative study/Classification Machine Learning coupled with LIBS gives a state of the art analytic method. Utility of the technic in safeguards security and non-proliferation

  9. Simulation of Multi Canister Overpack (MCO) Handling Machine Impact with Cask and MCO During Insertion into the Transfer Pit (FDT-137)

    Energy Technology Data Exchange (ETDEWEB)

    BAZINET, G.D.

    2000-04-13

    The K-Basin Cask and Transportation System will be used for safely packaging and transporting approximately 2,100 metric tons of unprocessed, spent nuclear fuel from the 105 K East and K West Basins to the 200 E Area Canister Storage Building (CSB). Portions of the system will also be used for drying the spent fuel under cold vacuum conditions prior to placement in interim storage. The spent nuclear fuel is currently stored underwater in the two K-Basins. The K-Basins loadout pit is the area selected for loading spent nuclear fuel into the Multi-Canister Overpack (MCO) which in turn is located within the transportation cask. This Cask/MCO unit is secured.in the pit with a pail load out structure whose primary function is lo suspend and support the Cask/MCO unit at.the desired elevations and to protect the unit from the contaminated K-Basin water. The fuel elements will be placed in special baskets and stacked in the MCO that have been previously placed in the cask. The casks will be removed from the K Basin load out areas and taken to the cold vacuum drying station. Then the cask will be prepared for transportation to the CSB. The shipments will occur exclusively on the Hanford Site between K-Basins and the CSB. Travel will be by road with one cask per trailer. At the CSB receiving area the cask will be removed from the trailer. A gantry crane will then move the cask over to the transfer pit and load the cask into the transfer pit. From the transfer pit the MCO will be removed from the cask by the MCO Handling Machine (MHM). The MHM will move the MCO from the transfer pit to a canister storage tube in the CSB. MCOs will be piled two high in each canister Storage tube.

  10. Simulation of Multi Canister Overpack (MCO) Handling Machine Impact with Cask and MCO During Insertion into the Transfer Pit (FDT-137)

    International Nuclear Information System (INIS)

    BAZINET, G.D.

    2000-01-01

    The K-Basin Cask and Transportation System will be used for safely packaging and transporting approximately 2,100 metric tons of unprocessed, spent nuclear fuel from the 105 K East and K West Basins to the 200 E Area Canister Storage Building (CSB). Portions of the system will also be used for drying the spent fuel under cold vacuum conditions prior to placement in interim storage. The spent nuclear fuel is currently stored underwater in the two K-Basins. The K-Basins loadout pit is the area selected for loading spent nuclear fuel into the Multi-Canister Overpack (MCO) which in turn is located within the transportation cask. This Cask/MCO unit is secured.in the pit with a pail load out structure whose primary function is lo suspend and support the Cask/MCO unit at.the desired elevations and to protect the unit from the contaminated K-Basin water. The fuel elements will be placed in special baskets and stacked in the MCO that have been previously placed in the cask. The casks will be removed from the K Basin load out areas and taken to the cold vacuum drying station. Then the cask will be prepared for transportation to the CSB. The shipments will occur exclusively on the Hanford Site between K-Basins and the CSB. Travel will be by road with one cask per trailer. At the CSB receiving area the cask will be removed from the trailer. A gantry crane will then move the cask over to the transfer pit and load the cask into the transfer pit. From the transfer pit the MCO will be removed from the cask by the MCO Handling Machine (MHM). The MHM will move the MCO from the transfer pit to a canister storage tube in the CSB. MCOs will be piled two high in each canister Storage tube

  11. Distributed and parallel approach for handle and perform huge datasets

    Science.gov (United States)

    Konopko, Joanna

    2015-12-01

    Big Data refers to the dynamic, large and disparate volumes of data comes from many different sources (tools, machines, sensors, mobile devices) uncorrelated with each others. It requires new, innovative and scalable technology to collect, host and analytically process the vast amount of data. Proper architecture of the system that perform huge data sets is needed. In this paper, the comparison of distributed and parallel system architecture is presented on the example of MapReduce (MR) Hadoop platform and parallel database platform (DBMS). This paper also analyzes the problem of performing and handling valuable information from petabytes of data. The both paradigms: MapReduce and parallel DBMS are described and compared. The hybrid architecture approach is also proposed and could be used to solve the analyzed problem of storing and processing Big Data.

  12. The accessibility, readability, and quality of online resources for gender affirming surgery.

    Science.gov (United States)

    Vargas, Christina R; Ricci, Joseph A; Lee, Michelle; Tobias, Adam M; Medalie, Daniel A; Lee, Bernard T

    2017-09-01

    The transgender population is disproportionally affected by health disparities related to access to care. In many communities, transgender specialists are geographically distant and locally available medical professionals may be unfamiliar with unique needs of transgender patients. As a result, use of Internet resources for information about gender affirming surgery is particularly important. This study simulates a patient search for online educational material about gender affirming surgery and evaluates the accessibility, readability, and quality of the information. An Internet search for the term "transgender surgery" was performed, and the first 10 relevant hits were identified. Readability was assessed using 10 established tests: Coleman-Liau, Flesch-Kincaid, FORCAST, Fry, Gunning Fog, New Dale-Chall, New Fog Count, Raygor Estimate, Simple Measure of Gobbledygook, and Flesch Reading Ease. Quality was assessed using Journal of the American Medical Association criteria and the DISCERN instrument. Review of 69 results was required to identify 10 sites with relevant patient information. There were 97 articles collected; overall mean reading level was 14.7. Individual Web site reading levels ranged from 12.0 to 17.5. All articles and Web sites exceeded the recommended sixth grade level. Quality ranged from 0 to 4 (Journal of the American Medical Association) and 35 to 79 (DISCERN) across Web sites. Web sites with relevant patient information about gender affirming surgery were difficult to identify from search results. The content of these sites universally exceeded the recommended reading level. A wide range of Web site quality was noted, and this may further complicate successful navigation. Barriers in access to appropriately written patient information on the Internet may contribute to disparities in referral, involvement, satisfaction, and outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Human machine interface to manually drive rhombic like vehicles in remote handling operations

    International Nuclear Information System (INIS)

    Lopes, Pedro; Vale, Alberto; Ventura, Rodrigo

    2015-01-01

    In the thermonuclear experimental reactor ITER, a vehicle named CTS is designed to transport a container with activated components inside the buildings. In nominal operations, the CTS is autonomously guided under supervision. However, in some unexpected situations, such as in rescue and recovery operations, the autonomous mode must be overridden and the CTS must be remotely guided by an operator. The CTS is a rhombic-like vehicle, with two drivable and steerable wheels along its longitudinal axis, providing omni-directional capabilities. The rhombic kinematics correspond to four control variables, which are difficult to manage in manual mode operation. This paper proposes a Human Machine Interface (HMI) to remotely guide the vehicle in manual mode. The proposed solution is implemented using a HMI with an encoder connected to a micro-controller and an analog 2-axis joystick. Experimental results were obtained comparing the proposed solution with other controller devices in different scenarios and using a software platform that simulates the kinematics and dynamics of the vehicle. (authors)

  14. Human machine interface to manually drive rhombic like vehicles in remote handling operations

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Pedro; Vale, Alberto [Instituto de Plasmas e Fusao Nuclear, Instituto Superior Tecnico, Universidade de Lisboa, Av. Rovisco Pais 1, 1049-001 Lisboa (Portugal); Ventura, Rodrigo [Institute for Systems and Robotics, Instituto Superior Tecnico, Universidade de Lisboa, Av. Rovisco Pais 1, 1049-001 Lisboa (Portugal)

    2015-07-01

    In the thermonuclear experimental reactor ITER, a vehicle named CTS is designed to transport a container with activated components inside the buildings. In nominal operations, the CTS is autonomously guided under supervision. However, in some unexpected situations, such as in rescue and recovery operations, the autonomous mode must be overridden and the CTS must be remotely guided by an operator. The CTS is a rhombic-like vehicle, with two drivable and steerable wheels along its longitudinal axis, providing omni-directional capabilities. The rhombic kinematics correspond to four control variables, which are difficult to manage in manual mode operation. This paper proposes a Human Machine Interface (HMI) to remotely guide the vehicle in manual mode. The proposed solution is implemented using a HMI with an encoder connected to a micro-controller and an analog 2-axis joystick. Experimental results were obtained comparing the proposed solution with other controller devices in different scenarios and using a software platform that simulates the kinematics and dynamics of the vehicle. (authors)

  15. The Machine within the Machine

    CERN Multimedia

    Katarina Anthony

    2014-01-01

    Although Virtual Machines are widespread across CERN, you probably won't have heard of them unless you work for an experiment. Virtual machines - known as VMs - allow you to create a separate machine within your own, allowing you to run Linux on your Mac, or Windows on your Linux - whatever combination you need.   Using a CERN Virtual Machine, a Linux analysis software runs on a Macbook. When it comes to LHC data, one of the primary issues collaborations face is the diversity of computing environments among collaborators spread across the world. What if an institute cannot run the analysis software because they use different operating systems? "That's where the CernVM project comes in," says Gerardo Ganis, PH-SFT staff member and leader of the CernVM project. "We were able to respond to experimentalists' concerns by providing a virtual machine package that could be used to run experiment software. This way, no matter what hardware they have ...

  16. Prediction of mortality after radical cystectomy for bladder cancer by machine learning techniques.

    Science.gov (United States)

    Wang, Guanjin; Lam, Kin-Man; Deng, Zhaohong; Choi, Kup-Sze

    2015-08-01

    Bladder cancer is a common cancer in genitourinary malignancy. For muscle invasive bladder cancer, surgical removal of the bladder, i.e. radical cystectomy, is in general the definitive treatment which, unfortunately, carries significant morbidities and mortalities. Accurate prediction of the mortality of radical cystectomy is therefore needed. Statistical methods have conventionally been used for this purpose, despite the complex interactions of high-dimensional medical data. Machine learning has emerged as a promising technique for handling high-dimensional data, with increasing application in clinical decision support, e.g. cancer prediction and prognosis. Its ability to reveal the hidden nonlinear interactions and interpretable rules between dependent and independent variables is favorable for constructing models of effective generalization performance. In this paper, seven machine learning methods are utilized to predict the 5-year mortality of radical cystectomy, including back-propagation neural network (BPN), radial basis function (RBFN), extreme learning machine (ELM), regularized ELM (RELM), support vector machine (SVM), naive Bayes (NB) classifier and k-nearest neighbour (KNN), on a clinicopathological dataset of 117 patients of the urology unit of a hospital in Hong Kong. The experimental results indicate that RELM achieved the highest average prediction accuracy of 0.8 at a fast learning speed. The research findings demonstrate the potential of applying machine learning techniques to support clinical decision making. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. 30o inclination in handles of plastic boxes can reduce postural and muscular workload during handling

    Directory of Open Access Journals (Sweden)

    Luciana C. C. B. Silva

    2013-06-01

    Full Text Available BACKGROUND: The handling of materials, which occurs in the industrial sector, is associated with lesions on the lumbar spine and in the upper limbs. Inserting handles in industrial boxes is a way to reduce work-related risks. Although the position and angle of the handles are significant factors in comfort and safety during handling, these factors have rarely been studied objectively. OBJECTIVE: To compare the handling of a commercial box and prototypes with handles and to evaluate the effects on upper limb posture, muscle electrical activity, and perceived acceptability using different grips while handling materials from different heights. METHOD: Thirty-seven healthy volunteers evaluated the handles of prototypes that allowed for changes in position (top and bottom and angle (0°, 15°, and 30°. Wrist, elbow, and shoulder movements were evaluated using electrogoniometry and inclinometry. The muscle electrical activity in the wrist extensors, biceps brachii, and the upper portion of the trapezius was measured using a portable electromyographer. The recorded data on muscle movements and electrical activity were synchronized. Subjective evaluations of acceptability were evaluated using a visual analog scale. RESULTS AND CONCLUSIONS: The prototypes with handles at a 30° angle produced the highest acceptability ratings, more neutral wrist positions, lower levels of electromyographic activity for the upper trapezius, and lower elevation angles for the arms. The different measurement methods were complementary in evaluating the upper limbs during handling.

  18. New transport and handling contract

    CERN Multimedia

    SC Department

    2008-01-01

    A new transport and handling contract entered into force on 1.10.2008. As with the previous contract, the user interface is the internal transport/handling request form on EDH: https://edh.cern.ch/Document/TransportRequest/ To ensure that you receive the best possible service, we invite you to complete the various fields as accurately as possible and to include a mobile telephone number on which we can reach you. You can follow the progress of your request (schedule, completion) in the EDH request routing information. We remind you that the following deadlines apply: 48 hours for the transport of heavy goods (up to 8 tonnes) or simple handling operations 5 working days for crane operations, transport of extra-heavy goods, complex handling operations and combined transport and handling operations in the tunnel. For all enquiries, the number to contact remains unchanged: 72202. Heavy Handling Section TS-HE-HH 72672 - 160319

  19. Improving the human readability of Arden Syntax medical logic modules using a concept-oriented terminology and object-oriented programming expressions.

    Science.gov (United States)

    Choi, Jeeyae; Bakken, Suzanne; Lussier, Yves A; Mendonça, Eneida A

    2006-01-01

    Medical logic modules are a procedural representation for sharing task-specific knowledge for decision support systems. Based on the premise that clinicians may perceive object-oriented expressions as easier to read than procedural rules in Arden Syntax-based medical logic modules, we developed a method for improving the readability of medical logic modules. Two approaches were applied: exploiting the concept-oriented features of the Medical Entities Dictionary and building an executable Java program to replace Arden Syntax procedural expressions. The usability evaluation showed that 66% of participants successfully mapped all Arden Syntax rules to Java methods. These findings suggest that these approaches can play an essential role in the creation of human readable medical logic modules and can potentially increase the number of clinical experts who are able to participate in the creation of medical logic modules. Although our approaches are broadly applicable, we specifically discuss the relevance to concept-oriented nursing terminologies and automated processing of task-specific nursing knowledge.

  20. Replacement Condition Detection of Railway Point Machines Using an Electric Current Sensor

    Science.gov (United States)

    Sa, Jaewon; Choi, Younchang; Chung, Yongwha; Kim, Hee-Young; Park, Daihee; Yoon, Sukhan

    2017-01-01

    Detecting replacement conditions of railway point machines is important to simultaneously satisfy the budget-limit and train-safety requirements. In this study, we consider classification of the subtle differences in the aging effect—using electric current shape analysis—for the purpose of replacement condition detection of railway point machines. After analyzing the shapes of after-replacement data and then labeling the shapes of each before-replacement data, we can derive the criteria that can handle the subtle differences between “does-not-need-to-be-replaced” and “needs-to-be-replaced” shapes. On the basis of the experimental results with in-field replacement data, we confirmed that the proposed method could detect the replacement conditions with acceptable accuracy, as well as provide visual interpretability of the criteria used for the time-series classification. PMID:28146057