WorldWideScience

Sample records for handheld instruments gertz

  1. The Public/Private Figure Status of Corporate and Executive Libel Plaintiffs after "Gertz."

    Science.gov (United States)

    Drechsel, Robert E.; Moon, Deborah

    Since 1974, when the Supreme Court concluded in "Gertz v. Robert Welch, Inc." that public figures and private figures deserve different treatment under libel law (with private figures needing a lower standard of proof), most lower courts have had to sort out the two categories. From the results in "Gertz" and other cases, three…

  2. New portable hand-held radiation instruments for measurements and monitoring

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1987-01-01

    Hand-held radiation monitors are often used to search pedestrians and motor vehicles for special nuclear material (SNM) as part of a physical protection plan for nuclear materials. Recently, the Los Alamos Advanced Nuclear Technology group has commercialized an improved hand-held monitor that can be used for both physical-protection monitoring and verification measurements in nuclear material control and waste management. The new monitoring instruments are smaller and lighter; operate much longer on a battery charge; are available with NaI(Tl) or neutron and gamma-ray sensitive plastic scintillation detectors; and are less expensive than other comparable instruments. They also have a second operating mode for making precise measurements over counting times as long as 99 s. This mode permits making basic verification measurements that may be needed before transporting nuclear material or waste outside protected areas. Improved verification measurements can be made with a second new hand-held instrument that has a stabilized detector and three separate gamma-ray energy windows to obtain spectral information for SNM quantity, enrichment, or material-type verification

  3. An Intelligent Hand-Held Microsurgical Instrument for Improved Accuracy

    National Research Council Canada - National Science Library

    Ang, Wei

    2001-01-01

    This paper presents the development and initial experimental results of the first prototype of Micron, an active hand-held instrument to sense and compensate physiological tremor and other unwanted...

  4. Judging Public Interest in Libel: The "Gertz" Decision's Contribution.

    Science.gov (United States)

    Helle, Steven

    1984-01-01

    Traces the public interest concept in libel to the time of "Gertz v. Robert Welch, Inc.," which supposedly rejected the concept, and beyond, demonstrating that the problem many free press advocates associate with the decision is really a consequence of the public interest test those same advocates cherish. (FL)

  5. Algorithms for a hand-held miniature x-ray fluorescence analytical instrument

    International Nuclear Information System (INIS)

    Elam, W.T.; Newman, D.; Ziemba, F.

    1998-01-01

    The purpose of this joint program was to provide technical assistance with the development of a Miniature X-ray Fluorescence (XRF) Analytical Instrument. This new XRF instrument is designed to overcome the weaknesses of spectrometers commercially available at the present time. Currently available XRF spectrometers (for a complete list see reference 1) convert spectral information to sample composition using the influence coefficients technique or the fundamental parameters method. They require either a standard sample with composition relatively close to the unknown or a detailed knowledge of the sample matrix. They also require a highly-trained operator and the results often depend on the capabilities of the operator. In addition, almost all existing field-portable, hand-held instruments use radioactive sources for excitation. Regulatory limits on such sources restrict them such that they can only provide relatively weak excitation. This limits all current hand-held XRF instruments to poor detection limits and/or long data collection times, in addition to the licensing requirements and disposal problems for radioactive sources. The new XRF instrument was developed jointly by Quantrad Sensor, Inc., the Naval Research Laboratory (NRL), and the Department of Energy (DOE). This report describes the analysis algorithms developed by NRL for the new instrument and the software which embodies them

  6. How State Courts Have Responded to "Gertz" in Setting Standards of Fault.

    Science.gov (United States)

    McCarthy, William Osler

    1979-01-01

    A review of recent state court decisions in libel cases suggests that the law of defamation is in as much disarray as it was when the Supreme Court recognized the problem and tried to remedy it with its 1974 decision in "Gertz v. Robert Welch Inc." (GT)

  7. Advanced sampling techniques for hand-held FT-IR instrumentation

    Science.gov (United States)

    Arnó, Josep; Frunzi, Michael; Weber, Chris; Levy, Dustin

    2013-05-01

    FT-IR spectroscopy is the technology of choice to identify solid and liquid phase unknown samples. The challenging ConOps in emergency response and military field applications require a significant redesign of the stationary FT-IR bench-top instruments typically used in laboratories. Specifically, field portable units require high levels of resistance against mechanical shock and chemical attack, ease of use in restrictive gear, extreme reliability, quick and easy interpretation of results, and reduced size. In the last 20 years, FT-IR instruments have been re-engineered to fit in small suitcases for field portable use and recently further miniaturized for handheld operation. This article introduces the HazMatID™ Elite, a FT-IR instrument designed to balance the portability advantages of a handheld device with the performance challenges associated with miniaturization. In this paper, special focus will be given to the HazMatID Elite's sampling interfaces optimized to collect and interrogate different types of samples: accumulated material using the on-board ATR press, dispersed powders using the ClearSampler™ tool, and the touch-to-sample sensor for direct liquid sampling. The application of the novel sample swipe accessory (ClearSampler) to collect material from surfaces will be discussed in some detail. The accessory was tested and evaluated for the detection of explosive residues before and after detonation. Experimental results derived from these investigations will be described in an effort to outline the advantages of this technology over existing sampling methods.

  8. Negligence 10 Years after Gertz v. Welch. Journalism Monographs Number Ninety-Three.

    Science.gov (United States)

    Hopkins, W. Wat

    The implications and shortcomings of court rulings on negligence in libel laws are explored in this paper. The paper first discusses the particulars of the 1974 landmark "Gertz versus Robert Welch, Inc." United States Supreme Court case, in which the court ruled that private persons as well as public figures would be required to prove…

  9. Purvin and Gertz

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    This paper reports on growing Asia Pacific gas demand through 2010 that will dramatically increase competition for imports and indigenous regional supplies, a Houston consulting firm says. Deregulation of Asia Pacific energy markets, increased environmental awareness, and greater emphasis on economics of interfuel competition are among major factors expected to affect Asia Pacific gas markets for the next two decades, says a study by Purvin and Gertz Inc. (P and G). Aside from government mandated constraints, future gas prices in each country studied generally will be related to costs of fuels with which gas competes in each end use sector, P and G says. With regional gas demand expected in 2010 to reach 9.2 tcf, P and G advises Asia Pacific consumers in all sectors to begin negotiating now for long term supplies. P and G says more than 50% of new regional gas demand through 2000 will come from increased gas usage in power generation. Most new thermal power generating plants planned in Asia Pacific countries will be either gas or coal fired. but other end use sectors also will play significant roles in future demand growth. P and G predicts liquefied natural gas demand through the end of the century will increase by 4.2%/year. During 2000-2010, Asia Pacific LNG demand will grow by about 3%/year. Regional LNG demand in 2010 will reach 80 million tons of oil equivalent (TOE), increasing from 67 million TOE in 2000 and 45 million TOE in 1990

  10. Hand-held medical robots.

    Science.gov (United States)

    Payne, Christopher J; Yang, Guang-Zhong

    2014-08-01

    Medical robots have evolved from autonomous systems to tele-operated platforms and mechanically-grounded, cooperatively-controlled robots. Whilst these approaches have seen both commercial and clinical success, uptake of these robots remains moderate because of their high cost, large physical footprint and long setup times. More recently, researchers have moved toward developing hand-held robots that are completely ungrounded and manipulated by surgeons in free space, in a similar manner to how conventional instruments are handled. These devices provide specific functions that assist the surgeon in accomplishing tasks that are otherwise challenging with manual manipulation. Hand-held robots have the advantages of being compact and easily integrated into the normal surgical workflow since there is typically little or no setup time. Hand-held devices can also have a significantly reduced cost to healthcare providers as they do not necessitate the complex, multi degree-of-freedom linkages that grounded robots require. However, the development of such devices is faced with many technical challenges, including miniaturization, cost and sterility, control stability, inertial and gravity compensation and robust instrument tracking. This review presents the emerging technical trends in hand-held medical robots and future development opportunities for promoting their wider clinical uptake.

  11. Handheld spectrometers: the state of the art

    Science.gov (United States)

    Crocombe, Richard A.

    2013-05-01

    "Small" spectrometers fall into three broad classes: small versions of laboratory instruments, providing data, subsequently processed on a PC; dedicated analyzers, providing actionable information to an individual operator; and process analyzers, providing quantitative or semi-quantitative information to a process controller. The emphasis of this paper is on handheld dedicated analyzers. Many spectrometers have historically been large, possible fragile, expensive and complicated to use. The challenge over the last dozen years, as instruments have moved into the field, has been to make spectrometers smaller, affordable, rugged, easy-to-use, but most of all capable of delivering actionable results. Actionable results can dramatically improve the efficiency of a testing process and transform the way business is done. There are several keys to this handheld spectrometer revolution. Consumer electronics has given us powerful mobile platforms, compact batteries, clearly visible displays, new user interfaces, etc., while telecomm has revolutionized miniature optics, sources and detectors. While these technologies enable miniature spectrometers themselves, actionable information has demanded the development of rugged algorithms for material confirmation, unknown identification, mixture analysis and detection of suspicious materials in unknown matrices. These algorithms are far more sophisticated than the `correlation' or `dot-product' methods commonly used in benchtop instruments. Finally, continuing consumer electronics advances now enable many more technologies to be incorporated into handheld spectrometers, including Bluetooth, wireless, WiFi, GPS, cameras and bar code readers, and the continued size shrinkage of spectrometer `engines' leads to the prospect of dual technology or `hyphenated' handheld instruments.

  12. Handheld Microfluidic Blood Ananlyzer, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Nanohmics proposes to develop a handheld blood analyzer for micro- and hypo-gravity missions. The prototype instrument will combine impedance analysis with optical...

  13. Handheld ultrahigh speed swept source optical coherence tomography instrument using a MEMS scanning mirror.

    Science.gov (United States)

    Lu, Chen D; Kraus, Martin F; Potsaid, Benjamin; Liu, Jonathan J; Choi, Woojhon; Jayaraman, Vijaysekhar; Cable, Alex E; Hornegger, Joachim; Duker, Jay S; Fujimoto, James G

    2013-12-20

    We developed an ultrahigh speed, handheld swept source optical coherence tomography (SS-OCT) ophthalmic instrument using a 2D MEMS mirror. A vertical cavity surface-emitting laser (VCSEL) operating at 1060 nm center wavelength yielded a 350 kHz axial scan rate and 10 µm axial resolution in tissue. The long coherence length of the VCSEL enabled a 3.08 mm imaging range with minimal sensitivity roll-off in tissue. Two different designs with identical optical components were tested to evaluate handheld OCT ergonomics. An iris camera aided in alignment of the OCT beam through the pupil and a manual fixation light selected the imaging region on the retina. Volumetric and high definition scans were obtained from 5 undilated normal subjects. Volumetric OCT data was acquired by scanning the 2.4 mm diameter 2D MEMS mirror sinusoidally in the fast direction and linearly in the orthogonal slow direction. A second volumetric sinusoidal scan was obtained in the orthogonal direction and the two volumes were processed with a software algorithm to generate a merged motion-corrected volume. Motion-corrected standard 6 x 6 mm(2) and wide field 10 x 10 mm(2) volumetric OCT data were generated using two volumetric scans, each obtained in 1.4 seconds. High definition 10 mm and 6 mm B-scans were obtained by averaging and registering 25 B-scans obtained over the same position in 0.57 seconds. One of the advantages of volumetric OCT data is the generation of en face OCT images with arbitrary cross sectional B-scans registered to fundus features. This technology should enable screening applications to identify early retinal disease, before irreversible vision impairment or loss occurs. Handheld OCT technology also promises to enable applications in a wide range of settings outside of the traditional ophthalmology or optometry clinics including pediatrics, intraoperative, primary care, developing countries, and military medicine.

  14. Application of Handheld Laser-Induced Breakdown Spectroscopy (LIBS) to Geochemical Analysis.

    Science.gov (United States)

    Connors, Brendan; Somers, Andrew; Day, David

    2016-05-01

    While laser-induced breakdown spectroscopy (LIBS) has been in use for decades, only within the last two years has technology progressed to the point of enabling true handheld, self-contained instruments. Several instruments are now commercially available with a range of capabilities and features. In this paper, the SciAps Z-500 handheld LIBS instrument functionality and sub-systems are reviewed. Several assayed geochemical sample sets, including igneous rocks and soils, are investigated. Calibration data are presented for multiple elements of interest along with examples of elemental mapping in heterogeneous samples. Sample preparation and the data collection method from multiple locations and data analysis are discussed. © The Author(s) 2016.

  15. Three-dimensional modeling of physiological tremor for hand-held surgical robotic instruments.

    Science.gov (United States)

    Tatinati, Sivanagaraja; Yan Naing Aye; Pual, Anand; Wei Tech Ang; Veluvolu, Kalyana C

    2016-08-01

    Hand-held robotic instruments are developed to compensate physiological tremor in real-time while augmenting the required precision and dexterity into normal microsurgical work-flow. The hardware (sensors and actuators) and software (causal linear filters) employed for tremor identification and filtering introduces time-varying unknown phase-delay that adversely affects the device performance. The current techniques that focus on three-dimensions (3D) tip position control involves modeling and canceling the tremor in 3-axes (x, y, and z axes) separately. Our analysis with the tremor data recorded from surgeons and novice subjects show that there exists significant correlation in tremor motion across the dimensions. Motivated by this, a new multi-dimensional modeling approach based on extreme learning machines (ELM) is proposed in this paper to correct the phase delay and to accurately model tremulous motion in three dimensions simultaneously. A study is conducted with tremor data recorded from the microsurgeons to analyze the suitability of proposed approach.

  16. An Enhanced Intelligent Handheld Instrument with Visual Servo Control for 2-DOF Hand Motion Error Compensation

    Directory of Open Access Journals (Sweden)

    Yan Naing Aye

    2013-10-01

    Full Text Available The intelligent handheld instrument, ITrem2, enhances manual positioning accuracy by cancelling erroneous hand movements and, at the same time, provides automatic micromanipulation functions. Visual data is acquired from a high speed monovision camera attached to the optical surgical microscope and acceleration measurements are acquired from the inertial measurement unit (IMU on board ITrem2. Tremor estimation and canceling is implemented via Band-limited Multiple Fourier Linear Combiner (BMFLC filter. The piezoelectric actuated micromanipulator in ITrem2 generates the 3D motion to compensate erroneous hand motion. Preliminary bench-top 2-DOF experiments have been conducted. The error motions simulated by a motion stage is reduced by 67% for multiple frequency oscillatory motions and 56.16% for pre-conditioned recorded physiological tremor.

  17. Handheld ESPI-speckle interferometer

    DEFF Research Database (Denmark)

    Skov Hansen, René

    2003-01-01

    . The interferometer presented here is a compact version of the set-up, Which is capable of measuring displacements of small objects, having either a specularly reflecting-or a diffusely scattering surface. The small optical set-up together with the use of the popular USB-communication for acquiring the images...... and controlling the phase of the reference wave constitutes a compact "handheld" instrument and eliminates the need for installing extra hardware, such as frame grabber and Digital to Analog converter, in the host computer....

  18. Data for Users of Handheld Ion Mobility Spectrometers

    International Nuclear Information System (INIS)

    Keith A. Daum; Sandra L. Fox

    2008-01-01

    Chemical detection technology end-user surveys conducted by Idaho National Laboratory (INL) in 2005 and 2007 indicated that first responders believed manufacturers claims for instruments sometimes were not supported in field applications, and instruments sometimes did not meet their actual needs. Based on these findings, the Department of Homeland Security (DHS) asked INL to conduct a similar survey for handheld ion mobility spectrometers (IMS), which are used by a broad community of first responders as well as for other applications. To better access this broad community, the INL used the Center for Technology Commercialization, Inc. (CTC), Public Safety Technology Center (PSTC) to set up an online framework to gather information from users of handheld IMS units. This framework (Survey Monkey) was then used to perform an online Internet survey, augmented by e-mail prompts, to get information from first responders and personnel from various agencies about their direct experience with handheld IMS units. Overall, 478 individuals responded to the survey. Of these, 174 respondents actually owned a handheld IMS. Performance and satisfaction data from these 174 respondents are captured in this report. The survey identified the following observations: (1) The most common IMS unit used by respondents was the Advanced Portable Detector (APD 2000), followed by ChemRae, Sabre 4000, Sabre 2000, Draeger Multi IMS, Chemical Agent Monitor-2, Chemical Agent Monitor, Vapor Tracer, and Vapor Tracer 2. (2) The primary owners were HazMat teams (20%), fire services (14%), local police (12%), and sheriffs departments (9%). (3) IMS units are seldom used as part of an integrated system for detecting and identifying chemicals but instead are used independently. (4) Respondents are generally confused about the capabilities of their IMS unit. This is probably a result of lack of training. (5) Respondents who had no training or fewer than 8 hours were not satisfied with the overall operation

  19. Handheld juggernaut.

    Science.gov (United States)

    Hagland, Mark

    2010-08-01

    Not only are hospital, health system, and medical group ClOs and clinical informaticists deploying handheld mobile devices across their enterprises as clinical computing tools; clinicians, especially physicians, are increasingly bringing their own BlackBerrys, iPhones, iPads, Android devices, and other handhelds, into patient care organizations for their personal clinical use. Not surprisingly, the challenges--as well as the opportunities--are multilayered and complex, and include the strategic planning, infrastructure, clinician preference, clinician workflow, and security issues involved in the emerging mobile handheld revolution. The diversity of approaches among ClOs and other healthcare IT leaders on such issues is striking, and underscores the need for flexibility and nimbleness going forward.

  20. Hand-held and automated breast ultrasound

    International Nuclear Information System (INIS)

    Bassett, L.W.; Gold, R.H.; Kimme-Smith, C.

    1985-01-01

    The book is a guide for physicians and technologists who use US as an adjunct to mammography; it carefully outlines the pros and cons of US of the breast and its role in the diagnosis of benign and malignant diseases. After an introduction that discusses the philosophy of breast US, the chapters cover the physics of US and instrumentation (both hand-held transducers as well as automated water path scanners), then proceed to a discussion of the normal breast. Sections on benign disorders, malignant lesions, and pitfalls of diagnosis are followed by quiz cases

  1. Development of a Novel Multispectral Instrument for Handheld and UAS Measurements of Surface Albedo; First Applications for Glaciers in the Peruvian Andes and for Nevada's Black Rock Desert

    Science.gov (United States)

    Boehmler, J. M.; Stevens, C.; Arnott, W. P.; Watts, A.; All, J.; Schmitt, C. G.

    2017-12-01

    Accurate atmospheric aerosol characteristics derived from satellite measurements are needed over a variety of land surfaces. Nonhomogeneous and bright surface reflectance across California and Nevada may be a contributing factor in the discrepancies observed between ground based and satellite-retrieved atmospheric aerosol optical depth (AOD). We developed and deployed a compact and portable instrument to measure albedo to evaluate a major factor that influences the accuracy of AOD retrievals. The instrument will be operated on an unmanned aircraft system (UAS) to control areal averaging for comparison with satellite derived albedo from the NASA Moderate Resolution Imaging Spectroradiometer (MODIS). A handheld version of the instrument was mounted on a trekking pole and used for obtaining in situ glacier albedo measurements in the Cordillera Blanca of Peru during the summer of 2017. The instrument weighs approximately 433 g and consists of two parts, a mountable, payload portion (300 g) which houses the sensors, and a handheld screen (133 g) to display real-time data from the payload portion. Both parts are powered by a 9V battery and run on a Teensy 3.6/3.2 microcontroller. To retrieve albedo, two micro-spectrometers manufactured by Hamamatsu Photonics, each with a spectral range of 340 -780 nm, are utilized; one for obtaining the downwelling solar radiation and the other for measuring the solar radiation reflected from the surface. Additional components on the instrument include temperature, pressure and humidity sensors with a one second time response; a GPS for position and altitude; an infrared sensor to measure ground temperature; a digital level and compass for orienting the instrument; a camera for taking photos of the sky and surface; a radio for two-way communication between the screen display and sensor payload; and a micro SD card for recording data. We will present the instrument design along with surface albedo measurements for glaciers of the Peruvian

  2. An integrated portable hand-held analyser for real-time isothermal nucleic acid amplification

    International Nuclear Information System (INIS)

    Smith, Matthew C.; Steimle, George; Ivanov, Stan; Holly, Mark; Fries, David P.

    2007-01-01

    A compact hand-held heated fluorometric instrument for performing real-time isothermal nucleic acid amplification and detection is described. The optoelectronic instrument combines a Printed Circuit Board/Micro Electro Mechanical Systems (PCB/MEMS) reaction detection/chamber containing an integrated resistive heater with attached miniature LED light source and photo-detector and a disposable glass waveguide capillary to enable a mini-fluorometer. The fluorometer is fabricated and assembled in planar geometry, rolled into a tubular format and packaged with custom control electronics to form the hand-held reactor. Positive or negative results for each reaction are displayed to the user using an LED interface. Reaction data is stored in FLASH memory for retrieval via an in-built USB connection. Operating on one disposable 3 V lithium battery >12, 60 min reactions can be performed. Maximum dimensions of the system are 150 mm (h) x 48 mm (d) x 40 mm (w), the total instrument weight (with battery) is 140 g. The system produces comparable results to laboratory instrumentation when performing a real-time nucleic acid sequence-based amplification (NASBA) reaction, and also displayed comparable precision, accuracy and resolution to laboratory-based real-time nucleic acid amplification instrumentation. A good linear response (R 2 = 0.948) to fluorescein gradients ranging from 0.5 to 10 μM was also obtained from the instrument indicating that it may be utilized for other fluorometric assays. This instrument enables an inexpensive, compact approach to in-field genetic screening, providing results comparable to laboratory equipment with rapid user feedback as to the status of the reaction

  3. An integrated portable hand-held analyser for real-time isothermal nucleic acid amplification

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Matthew C. [College of Marine Science, University of South Florida, St Petersburg, FL (United States)], E-mail: msmith@marine.usf.edu; Steimle, George; Ivanov, Stan; Holly, Mark; Fries, David P. [College of Marine Science, University of South Florida, St Petersburg, FL (United States)

    2007-08-29

    A compact hand-held heated fluorometric instrument for performing real-time isothermal nucleic acid amplification and detection is described. The optoelectronic instrument combines a Printed Circuit Board/Micro Electro Mechanical Systems (PCB/MEMS) reaction detection/chamber containing an integrated resistive heater with attached miniature LED light source and photo-detector and a disposable glass waveguide capillary to enable a mini-fluorometer. The fluorometer is fabricated and assembled in planar geometry, rolled into a tubular format and packaged with custom control electronics to form the hand-held reactor. Positive or negative results for each reaction are displayed to the user using an LED interface. Reaction data is stored in FLASH memory for retrieval via an in-built USB connection. Operating on one disposable 3 V lithium battery >12, 60 min reactions can be performed. Maximum dimensions of the system are 150 mm (h) x 48 mm (d) x 40 mm (w), the total instrument weight (with battery) is 140 g. The system produces comparable results to laboratory instrumentation when performing a real-time nucleic acid sequence-based amplification (NASBA) reaction, and also displayed comparable precision, accuracy and resolution to laboratory-based real-time nucleic acid amplification instrumentation. A good linear response (R{sup 2} = 0.948) to fluorescein gradients ranging from 0.5 to 10 {mu}M was also obtained from the instrument indicating that it may be utilized for other fluorometric assays. This instrument enables an inexpensive, compact approach to in-field genetic screening, providing results comparable to laboratory equipment with rapid user feedback as to the status of the reaction.

  4. Discrimination of Pigments of Microalgae, Bacteria and Yeasts Using Lightweight Handheld Raman Spectrometers: Prospects for Astrobiology

    Science.gov (United States)

    Jehlicka, J.; Osterrothova, K.; Nedbalova, L.; Gunde-Cimerman, N.; Oren, A.

    2014-06-01

    Handheld Raman instrumentation with 532 nm lasers can be used to distinguish carotenoids of autotrophic microalgae, purple sulfur bacteria, halophilic Archaea and pigmented yeasts. Pigments are proposed as biomarkers for astrobiology of Mars.

  5. Active case finding strategy for chronic obstructive pulmonary disease with handheld spirometry.

    Science.gov (United States)

    Kim, Joo Kyung; Lee, Chang Min; Park, Ji Young; Kim, Joo Hee; Park, Sung-Hoon; Jang, Seung Hun; Jung, Ki-Suck; Yoo, Kwang Ha; Park, Yong Bum; Rhee, Chin Kook; Kim, Deog Kyeom; Hwang, Yong Il

    2016-12-01

    The early detection and diagnosis of chronic obstructive pulmonary disease (COPD) is critical to providing appropriate and timely treatment. We explored a new active case-finding strategy for COPD using handheld spirometry.We recruited subjects over 40 years of age with a smoking history of more than 10 pack-years who visited a primary clinic complaining of respiratory symptoms. A total of 190 of subjects were enrolled. Medical information was obtained from historical records and physical examination by general practitioners. All subjects had their pulmonary function evaluated using handheld spirometry with a COPD-6 device. Because forced expiratory volume in 6 seconds (FEV6) has been suggested as an alternative to FVC, we measured forced expiratory volume in 1 second (FEV1)/FEV6 for diagnosis of airflow limitation. All subjects were then referred to tertiary referral hospitals to complete a "Could it be COPD?" questionnaire, handheld spiromtery, and conventional spirometry. The results of each instrument were compared to evaluate the efficacy of both handheld spirometry and the questionnaire.COPD was newly diagnosed in 45 (23.7%) patients. According to our receiver-operating characteristic (ROC) curve analysis, sensitivity and specificity were maximal when the FEV1/FEV6 ratio was less than 77%. The area under the ROC curve was 0.759. The sensitivity, specificity, positive predictive value, and negative predictive value were 72.7%, 77.1%, 50%, and 90%, respectively. The area under the ROC curve of respiratory symptoms listed on the questionnaire ranged from 0.5 to 0.65, which indicates that there is almost no difference compared with the results of handheld spirometry.The present study demonstrated the efficacy of handheld spirometry as an active case-finding tool for COPD in a primary clinical setting. This study suggested that physicians should recommend handheld spirometry for people over the age of 40, who have a smoking history of more than 10 pack

  6. A hand-held beta imaging probe for FDG.

    Science.gov (United States)

    Singh, Bipin; Stack, Brendan C; Thacker, Samta; Gaysinskiy, Valeriy; Bartel, Twyla; Lowe, Val; Cool, Steven; Entine, Gerald; Nagarkar, Vivek

    2013-04-01

    Advances in radiopharmaceuticals and clinical understanding have escalated the use of intraoperative gamma probes in surgery. However, most probes on the market are non-imaging gamma probes that suffer from the lack of ancillary information of the surveyed tissue area. We have developed a novel, hand-held digital Imaging Beta Probe™ (IBP™) to be used in surgery in conjunction with beta-emitting radiopharmaceuticals such as (18)FDG, (131)I and (32)P for real-time imaging of a surveyed area with higher spatial resolution and sensitivity and greater convenience than existing instruments. We describe the design and validation of a hand-held beta probe intended to be used as a visual mapping device to locate and confirm excision of (18)FDG-avid primary tumors and metastases in an animal model. We have demonstrated a device which can generate beta images from (18)FDG avid lesions in an animal model. It is feasible to image beta irradiation in animal models of cancer given (18)FDG. This technology may be applied to clinical mapping of tumors and/or their metastases in the operating room. Visual image depiction of malignancy may aid the surgeon in localization and excision of lesions of interest.

  7. A BODIPY-Based Fluorescent Probe to Visually Detect Phosgene: Toward the Development of a Handheld Phosgene Detector.

    Science.gov (United States)

    Sayar, Melike; Karakuş, Erman; Güner, Tuğrul; Yildiz, Busra; Yildiz, Umit Hakan; Emrullahoğlu, Mustafa

    2018-03-02

    A boron-dipyrromethene (BODIPY)-based fluorescent probe with a phosgene-specific reactive motif shows remarkable selectivity toward phosgene, in the presence of which the nonfluorescent dye rapidly transforms into a new structure and induces a fluorescent response clearly observable to the naked eye under ultraviolet light. Given that dynamic, a prototypical handheld phosgene detector with a promising sensing capability that expedites the detection of gaseous phosgene without sophisticated instrumentation was developed. The proposed method using the handheld detector involves a rapid response period suitable for issuing early warnings during emergency situations. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. 30 CFR 56.12033 - Hand-held electric tools.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL....12033 Hand-held electric tools. Hand-held electric tools shall not be operated at high potential...

  9. 30 CFR 57.12033 - Hand-held electric tools.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...

  10. Hand-held transendoscopic robotic manipulators: A transurethral laser prostate surgery case study.

    Science.gov (United States)

    Hendrick, Richard J; Mitchell, Christopher R; Herrell, S Duke; Webster, Robert J

    2015-11-01

    Natural orifice endoscopic surgery can enable incisionless approaches, but a major challenge is the lack of small and dexterous instrumentation. Surgical robots have the potential to meet this need yet often disrupt the clinical workflow. Hand-held robots that combine thin manipulators and endoscopes have the potential to address this by integrating seamlessly into the clinical workflow and enhancing dexterity. As a case study illustrating the potential of this approach, we describe a hand-held robotic system that passes two concentric tube manipulators through a 5 mm port in a rigid endoscope for transurethral laser prostate surgery. This system is intended to catalyze the use of a clinically superior, yet rarely attempted, procedure for benign prostatic hyperplasia. This paper describes system design and experiments to evaluate the surgeon's functional workspace and accuracy using the robot. Phantom and cadaver experiments demonstrate successful completion of the target procedure via prostate lobe resection.

  11. Correcting for motion artifact in handheld laser speckle images

    Science.gov (United States)

    Lertsakdadet, Ben; Yang, Bruce Y.; Dunn, Cody E.; Ponticorvo, Adrien; Crouzet, Christian; Bernal, Nicole; Durkin, Anthony J.; Choi, Bernard

    2018-03-01

    Laser speckle imaging (LSI) is a wide-field optical technique that enables superficial blood flow quantification. LSI is normally performed in a mounted configuration to decrease the likelihood of motion artifact. However, mounted LSI systems are cumbersome and difficult to transport quickly in a clinical setting for which portability is essential in providing bedside patient care. To address this issue, we created a handheld LSI device using scientific grade components. To account for motion artifact of the LSI device used in a handheld setup, we incorporated a fiducial marker (FM) into our imaging protocol and determined the difference between highest and lowest speckle contrast values for the FM within each data set (Kbest and Kworst). The difference between Kbest and Kworst in mounted and handheld setups was 8% and 52%, respectively, thereby reinforcing the need for motion artifact quantification. When using a threshold FM speckle contrast value (KFM) to identify a subset of images with an acceptable level of motion artifact, mounted and handheld LSI measurements of speckle contrast of a flow region (KFLOW) in in vitro flow phantom experiments differed by 8%. Without the use of the FM, mounted and handheld KFLOW values differed by 20%. To further validate our handheld LSI device, we compared mounted and handheld data from an in vivo porcine burn model of superficial and full thickness burns. The speckle contrast within the burn region (KBURN) of the mounted and handheld LSI data differed by burns. Collectively, our results suggest the potential of handheld LSI with an FM as a suitable alternative to mounted LSI, especially in challenging clinical settings with space limitations such as the intensive care unit.

  12. Application of handheld devices to field research among underserved construction worker populations: a workplace health assessment pilot study

    Directory of Open Access Journals (Sweden)

    Fleming Lora E

    2011-04-01

    Full Text Available Abstract Background Novel low-cost approaches for conducting rapid health assessments and health promotion interventions among underserved worker groups are needed. Recruitment and participation of construction workers is particularly challenging due to their often transient periods of work at any one construction site, and their limited time during work to participate in such studies. In the present methodology report, we discuss the experience, advantages and disadvantages of using touch screen handheld devices for the collection of field data from a largely underserved worker population. Methods In March 2010, a workplace-centered pilot study to examine the feasibility of using a handheld personal device for the rapid health assessment of construction workers in two South Florida Construction sites was undertaken. A 45-item survey instrument, including health-related questions on tobacco exposure, workplace safety practices, musculoskeletal disorders and health symptoms, was programmed onto Apple iPod Touch® devices. Language sensitive (English and Spanish recruitment scripts, verbal consent forms, and survey questions were all preloaded onto the handheld devices. The experience (time to survey administration and capital cost of the handheld administration method was recorded and compared to approaches available in the extant literature. Results Construction workers were very receptive to the recruitment, interview and assessment processes conducted through the handheld devices. Some workers even welcomed the opportunity to complete the questionnaire themselves using the touch screen handheld device. A list of advantages and disadvantages emerged from this experience that may be useful in the rapid health assessment of underserved populations working in a variety of environmental and occupational health settings. Conclusions Handheld devices, which are relatively inexpensive, minimize survey response error, and allow for easy storage of data

  13. Application of handheld devices to field research among underserved construction worker populations: a workplace health assessment pilot study.

    Science.gov (United States)

    Caban-Martinez, Alberto J; Clarke, Tainya C; Davila, Evelyn P; Fleming, Lora E; Lee, David J

    2011-04-01

    Novel low-cost approaches for conducting rapid health assessments and health promotion interventions among underserved worker groups are needed. Recruitment and participation of construction workers is particularly challenging due to their often transient periods of work at any one construction site, and their limited time during work to participate in such studies. In the present methodology report, we discuss the experience, advantages and disadvantages of using touch screen handheld devices for the collection of field data from a largely underserved worker population. In March 2010, a workplace-centered pilot study to examine the feasibility of using a handheld personal device for the rapid health assessment of construction workers in two South Florida Construction sites was undertaken. A 45-item survey instrument, including health-related questions on tobacco exposure, workplace safety practices, musculoskeletal disorders and health symptoms, was programmed onto Apple iPod Touch® devices. Language sensitive (English and Spanish) recruitment scripts, verbal consent forms, and survey questions were all preloaded onto the handheld devices. The experience (time to survey administration and capital cost) of the handheld administration method was recorded and compared to approaches available in the extant literature. Construction workers were very receptive to the recruitment, interview and assessment processes conducted through the handheld devices. Some workers even welcomed the opportunity to complete the questionnaire themselves using the touch screen handheld device. A list of advantages and disadvantages emerged from this experience that may be useful in the rapid health assessment of underserved populations working in a variety of environmental and occupational health settings. Handheld devices, which are relatively inexpensive, minimize survey response error, and allow for easy storage of data. These technological research modalities are useful in the

  14. Image Quality Characteristics of Handheld Display Devices for Medical Imaging

    Science.gov (United States)

    Yamazaki, Asumi; Liu, Peter; Cheng, Wei-Chung; Badano, Aldo

    2013-01-01

    Handheld devices such as mobile phones and tablet computers have become widespread with thousands of available software applications. Recently, handhelds are being proposed as part of medical imaging solutions, especially in emergency medicine, where immediate consultation is required. However, handheld devices differ significantly from medical workstation displays in terms of display characteristics. Moreover, the characteristics vary significantly among device types. We investigate the image quality characteristics of various handheld devices with respect to luminance response, spatial resolution, spatial noise, and reflectance. We show that the luminance characteristics of the handheld displays are different from those of workstation displays complying with grayscale standard target response suggesting that luminance calibration might be needed. Our results also demonstrate that the spatial characteristics of handhelds can surpass those of medical workstation displays particularly for recent generation devices. While a 5 mega-pixel monochrome workstation display has horizontal and vertical modulation transfer factors of 0.52 and 0.47 at the Nyquist frequency, the handheld displays released after 2011 can have values higher than 0.63 at the respective Nyquist frequencies. The noise power spectra for workstation displays are higher than 1.2×10−5 mm2 at 1 mm−1, while handheld displays have values lower than 3.7×10−6 mm2. Reflectance measurements on some of the handheld displays are consistent with measurements for workstation displays with, in some cases, low specular and diffuse reflectance coefficients. The variability of the characterization results among devices due to the different technological features indicates that image quality varies greatly among handheld display devices. PMID:24236113

  15. Wireless Handhelds to Support Clinical Nursing Practicum

    Science.gov (United States)

    Wu, Cheng-Chih; Lai, Chin-Yuan

    2009-01-01

    This paper reports our implementation and evaluation of a wireless handheld learning environment used to support a clinical nursing practicum course. The learning environment was designed so that nursing students could use handhelds for recording information, organizing ideas, assessing patients, and also for interaction and collaboration with…

  16. Fast, cheap and in control: spectral imaging with handheld devices

    Science.gov (United States)

    Gooding, Edward A.; Deutsch, Erik R.; Huehnerhoff, Joseph; Hajian, Arsen R.

    2017-05-01

    Remote sensing has moved out of the laboratory and into the real world. Instruments using reflection or Raman imaging modalities become faster, cheaper and more powerful annually. Enabling technologies include virtual slit spectrometer design, high power multimode diode lasers, fast open-loop scanning systems, low-noise IR-sensitive array detectors and low-cost computers with touchscreen interfaces. High-volume manufacturing assembles these components into inexpensive portable or handheld devices that make possible sophisticated decision-making based on robust data analytics. Examples include threat, hazmat and narcotics detection; remote gas sensing; biophotonic screening; environmental remediation and a host of other applications.

  17. Digital forensics for handheld devices

    CERN Document Server

    Doherty, Eamon P

    2012-01-01

    Approximately 80 percent of the world's population now owns a cell phone, which can hold evidence or contain logs about communications concerning a crime. Cameras, PDAs, and GPS devices can also contain information related to corporate policy infractions and crimes. Aimed to prepare investigators in the public and private sectors, Digital Forensics for Handheld Devices examines both the theoretical and practical aspects of investigating handheld digital devices. This book touches on all areas of mobile device forensics, including topics from the legal, technical, academic, and social aspects o

  18. ITSY Handheld Software Radio

    National Research Council Canada - National Science Library

    Bose, Vanu

    2001-01-01

    .... A handheld software radio platform would enable the construction of devices that could inter-operate with multiple legacy systems, download new waveforms and be used to construct adhoc networks...

  19. Assessment of Laparoscopic Skills Performance: 2D Versus 3D Vision and Classic Instrument Versus New Hand-Held Robotic Device for Laparoscopy.

    Science.gov (United States)

    Leite, Mariana; Carvalho, Ana F; Costa, Patrício; Pereira, Ricardo; Moreira, Antonio; Rodrigues, Nuno; Laureano, Sara; Correia-Pinto, Jorge; Vilaça, João L; Leão, Pedro

    2016-02-01

    Laparoscopic surgery has undeniable advantages, such as reduced postoperative pain, smaller incisions, and faster recovery. However, to improve surgeons' performance, ergonomic adaptations of the laparoscopic instruments and introduction of robotic technology are needed. The aim of this study was to ascertain the influence of a new hand-held robotic device for laparoscopy (HHRDL) and 3D vision on laparoscopic skills performance of 2 different groups, naïve and expert. Each participant performed 3 laparoscopic tasks-Peg transfer, Wire chaser, Knot-in 4 different ways. With random sequencing we assigned the execution order of the tasks based on the first type of visualization and laparoscopic instrument. Time to complete each laparoscopic task was recorded and analyzed with one-way analysis of variance. Eleven experts and 15 naïve participants were included. Three-dimensional video helps the naïve group to get better performance in Peg transfer, Wire chaser 2 hands, and Knot; the new device improved the execution of all laparoscopic tasks (P < .05). For expert group, the 3D video system benefited them in Peg transfer and Wire chaser 1 hand, and the robotic device in Peg transfer, Wire chaser 1 hand, and Wire chaser 2 hands (P < .05). The HHRDL helps the execution of difficult laparoscopic tasks, such as Knot, in the naïve group. Three-dimensional vision makes the laparoscopic performance of the participants without laparoscopic experience easier, unlike those with experience in laparoscopic procedures. © The Author(s) 2015.

  20. Rapid and automatic chemical identification of the medicinal flower buds of Lonicera plants by the benchtop and hand-held Fourier transform infrared spectroscopy

    Science.gov (United States)

    Chen, Jianbo; Guo, Baolin; Yan, Rui; Sun, Suqin; Zhou, Qun

    2017-07-01

    With the utilization of the hand-held equipment, Fourier transform infrared (FT-IR) spectroscopy is a promising analytical technique to minimize the time cost for the chemical identification of herbal materials. This research examines the feasibility of the hand-held FT-IR spectrometer for the on-site testing of herbal materials, using Lonicerae Japonicae Flos (LJF) and Lonicerae Flos (LF) as examples. Correlation-based linear discriminant models for LJF and LF are established based on the benchtop and hand-held FT-IR instruments. The benchtop FT-IR models can exactly recognize all articles of LJF and LF. Although a few LF articles are misjudged at the sub-class level, the hand-held FT-IR models are able to exactly discriminate LJF and LF. As a direct and label-free analytical technique, FT-IR spectroscopy has great potential in the rapid and automatic chemical identification of herbal materials either in laboratories or in fields. This is helpful to prevent the spread and use of adulterated herbal materials in time.

  1. Ergonomic investigation of weight distribution of laparoscopic instruments.

    Science.gov (United States)

    Lin, Chiuhsiang Joe; Chen, Hung-Jen; Lo, Ying-Chu

    2011-06-01

    Laparoscopic surgery procedures require highly specialized visually controlled movements. Investigations of industrial applications indicate that the length as well as the weight of hand-held tools substantially affects movement time (MT). Different weight distributions may have similar effects on long-shafted laparoscopic instruments when performing surgical procedures. For this reason, the current experiment aimed at finding direct evidence of the weight distribution effect in an accurate task. Ten right-handed subjects made continuous Fitts' pointing tasks using a long laparoscopic instrument. The factors and levels were target width: (2.5, 3, 3.5, and 4 cm), target distance (14, 23, and 37 cm), and weight distribution (uniform, front, middle, and rear). Weight distribution was made by chips of lead attached to the laparoscopic instrument. MT, error rate, and throughput (TP) were recorded as dependent variables. There were significant differences between the weight distribution in MT and in TP. The middle position was found to require the least time to manipulate the laparoscopic instrument in pointing tasks and also obtained the highest TP. These analyses and findings pointed to a design direction for the ergonomics and usability of the long hand-held tool such as the laparoscopic instrument in this study. To optimize efficiency in using these tools, the consideration of a better weight design is important and should not be neglected.

  2. Smart instrumentation development at Los Alamos

    International Nuclear Information System (INIS)

    Erkkila, B.

    1984-01-01

    For several years Los Alamos has incorporated microprocessors into instruments to expand the capability of portable survey type equipment. Beginning with portable pulse height analyzers, the developments have expanded to small dedicated instruments which handle the measurement and interpretation of various radiation fields. So far, instruments to measure gamma rays, neutrons, and beta particles have been produced. The computer capability built into these instruments provides significant computational power into the instruments. Capability unheard of a few years ago in small portable instruments is routine today. Large computer-based laboratory measurement systems which required much space and electrical power can now be incorporated in a portable hand-held instrument. The microprocessor developments at Los Alamos are now restricted to radiation monitoring equipment but can be expanded to chemical and biological applications as well. Applications for radiation monitoring equipment and others are discussed

  3. Introduction of handheld computing to a family practice residency program.

    Science.gov (United States)

    Rao, Goutham

    2002-01-01

    Handheld computers are valuable practice tools. It is important for residency programs to introduce their trainees and faculty to this technology. This article describes a formal strategy to introduce handheld computing to a family practice residency program. Objectives were selected for the handheld computer training program that reflected skills physicians would find useful in practice. TRGpro handheld computers preloaded with a suite of medical reference programs, a medical calculator, and a database program were supplied to participants. Training consisted of four 1-hour modules each with a written evaluation quiz. Participants completed a self-assessment questionnaire after the program to determine their ability to meet each objective. Sixty of the 62 participants successfully completed the training program. The mean composite score on quizzes was 36 of 40 (90%), with no significant differences by level of residency training. The mean self-ratings of participants across all objectives was 3.31 of 4.00. Third-year residents had higher mean self-ratings than others (mean of group, 3.62). Participants were very comfortable with practical skills, such as using drug reference software, and less comfortable with theory, such as knowing the different types of handheld computers available. Structured training is a successful strategy for introducing handheld computing to a residency program.

  4. Navigating on handheld displays: Dynamic versus Static Keyhole Navigation

    NARCIS (Netherlands)

    Mehra, S.; Werkhoven, P.; Worring, M.

    2006-01-01

    Handheld displays leave little space for the visualization and navigation of spatial layouts representing rich information spaces. The most common navigation method for handheld displays is static peephole navigation: The peephole is static and we move the spatial layout behind it (scrolling). A

  5. 3D Scan of Ornamental Column (huabiao Using Terrestrial LiDAR and Hand-held Imager

    Directory of Open Access Journals (Sweden)

    W. Zhang

    2015-08-01

    Full Text Available In ancient China, Huabiao was a type of ornamental column used to decorate important buildings. We carried out 3D scan of a Huabiao located in Peking University, China. This Huabiao was built no later than 1742. It is carved by white marble, 8 meters in height. Clouds and various postures of dragons are carved on its body. Two instruments were used to acquire the point cloud of this Huabiao, a terrestrial LiDAR (Riegl VZ-1000 and a hand-held imager (Mantis Vision F5. In this paper, the details of the experiment were described, including the differences between these two instruments, such as working principle, spatial resolution, accuracy, instrument dimension and working flow. The point clouds obtained respectively by these two instruments were compared, and the registered point cloud of Huabiao was also presented. These should be of interest and helpful for the research communities of archaeology and heritage.

  6. Doctors' experience with handheld computers in clinical practice: qualitative study.

    Science.gov (United States)

    McAlearney, Ann Scheck; Schweikhart, Sharon B; Medow, Mitchell A

    2004-05-15

    To examine doctors' perspectives about their experiences with handheld computers in clinical practice. Qualitative study of eight focus groups consisting of doctors with diverse training and practice patterns. Six practice settings across the United States and two additional focus group sessions held at a national meeting of general internists. 54 doctors who did or did not use handheld computers. Doctors who used handheld computers in clinical practice seemed generally satisfied with them and reported diverse patterns of use. Users perceived that the devices helped them increase productivity and improve patient care. Barriers to use concerned the device itself and personal and perceptual constraints, with perceptual factors such as comfort with technology, preference for paper, and the impression that the devices are not easy to use somewhat difficult to overcome. Participants suggested that organisations can help promote handheld computers by providing advice on purchase, usage, training, and user support. Participants expressed concern about reliability and security of the device but were particularly concerned about dependency on the device and over-reliance as a substitute for clinical thinking. Doctors expect handheld computers to become more useful, and most seem interested in leveraging (getting the most value from) their use. Key opportunities with handheld computers included their use as a stepping stone to build doctors' comfort with other information technology and ehealth initiatives and providing point of care support that helps improve patient care.

  7. Instrument Records And Plays Back Acceleration Signals

    Science.gov (United States)

    Bozeman, Richard J.

    1994-01-01

    Small, battery-powered, hand-held instrument feeds power to accelerometer and records time-varying component of output for 15 seconds in analog form. No power needed to maintain content of memory; memory chip removed after recording and stored indefinitely. Recorded signal plays back at any time up to several years later. Principal advantages: compactness, portability, and low cost.

  8. Instrument evaluation no. 9. Mini-instruments dose rate meter type 5 - 1OR

    International Nuclear Information System (INIS)

    Iles, W.J.; Burgess, P.H.; Callowhill, K.

    1977-04-01

    This instrument is a portable, battery powered dose rate meter covering the dose rate range from 0 to 200 mrad h -1 . The instrument is designed to measure X- and γ-radiation dose rates over the energy range from 45 keV to 3 MeV. The radiation detector of the instrument is a GM tube with a specially designed energy compensation sheath. This detector is incorporated in a probe connected to the rate meter by an extensible cable which may be either hand-held or clipped on to the top of the instrument case. All the measurements in this report have been taken with the long axis of the probe normal to the direction of the incident radiation, the orientation recommended by the manufacturer. The information is given under the following headings: facilities and controls; radiation characteristics; electrical characteristics; effect of ambient temperature; mechanical characteristics; summary of performance; conclusions. (U.K.)

  9. Health physics instrumentation - a progress report

    International Nuclear Information System (INIS)

    Maushart, R.

    1992-01-01

    Health Physics Instruments have changed rather dramatically in the past decade. On the one hand, technological innovations like Microprocessors, data storage facilities and imaging displays have altered shape, size and appearance of the classical devices, particularly the hand-held ones. On the other hand, instruments are increasingly being considered as an integral part of Radiation Protection procedures and organizations, supporting a smooth and reliable implementation of all necessary measures. This implies ease of operation, and extensive self-checking and performance control features. Since there are different categories of users with quite different degrees of motivation and training, the measuring instruments of the future will have to be adapted to specific types of users. Instruments for 'professional' radiation protection - for example in nuclear power plants and nuclear technology - will differ from instruments used in the radionuclide laboratory, where radiation protection will necessarily have to be done as a 'side-job'. (author)

  10. A handheld open-field infant keratometer (an american ophthalmological society thesis).

    Science.gov (United States)

    Miller, Joseph M

    2010-12-01

    To design and evaluate a new infant keratometer that incorporates an unobstructed view of the infant with both eyes (open-field design). The design of the open-field infant keratometer is presented, and details of its construction are given. The design incorporates a single-ring keratoscope for measurement of corneal astigmatism over a 4-mm region of the cornea and includes a rectangular grid target concentric within the ring to allow for the study of higher-order aberrations of the eye. In order to calibrate the lens and imaging system, a novel telecentric test object was constructed and used. The system was bench calibrated against steel ball bearings of known dimensions and evaluated for accuracy while being used in handheld mode in a group of 16 adult cooperative subjects. It was then evaluated for testability in a group of 10 infants and toddlers. Results indicate that while the device achieved the goal of creating an open-field instrument containing a single-ring keratoscope with a concentric grid array for the study of higher-order aberrations, additional work is required to establish better control of the vertex distance. The handheld open-field infant keratometer demonstrates testability suitable for the study of infant corneal astigmatism. Use of collimated light sources in future iterations of the design must be incorporated in order to achieve the accuracy required for clinical investigation.

  11. Electronic prescribing: criteria for evaluating handheld prescribing systems and an evaluation of a new, handheld, wireless wide area network (WWAN) prescribing system.

    Science.gov (United States)

    Goldblum, O M

    2001-02-01

    The objectives of this study were: 1) to establish criteria for evaluating handheld computerized prescribing systems; and 2) to evaluate out-of-box performance and features of a new, Palm Operating System (OS)-based, handheld, wireless wide area network (WWAN) prescribing system. The system consisted of a Palm Vx handheld organizer, a Novatel Minstrel V wireless modem, OmniSky wireless internet access and ePhysician ePad 1.1, the Palm OS electronic prescribing software program. A dermatologist familiar with healthcare information technology conducted an evaluation of the performance and features of a new, handheld, WWAN electronic prescribing system in an office practice during a three-month period in 2000. System performance, defined as transmission success rate, was determined from data collected during the three-month trial. Evaluation criteria consisted of an analysis of features found in electronic prescribing systems. All prescriptions written for all patients seen during a three-month period (August - November, 2000) were eligible for inclusion. Prescriptions written for patients who intended to fill them at pharmacies without known facsimile receiving capabilities were excluded from the study. The performance of the system was evaluated using data collected during the study. Criteria for evaluating features of electronic prescribing systems were developed and used to analyze the system employed in this study. During this three-month trial, 200 electronic prescriptions were generated for 132 patients included in the study. Of these prescriptions, 92.5 percent were successfully transmitted to pharmacies. Transmission failures resulted from incorrect facsimile numbers and non-functioning facsimile machines. Criteria established for evaluation of electronic prescribing systems included System (Hardware & Software), Costs, System Features, Printing & Transmission, Formulary & Insurance, Customization, Drug Safety and Security. This study is the first effort to

  12. Handheld CAT Video Game, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed project is to design, develop and fabricate a handheld video game console for astronauts during long space flight. This portable hardware runs...

  13. A Cognitive Style Perspective to Handheld Devices: Customization vs. Personalization

    Science.gov (United States)

    Hsieh, Chen-Wei; Chen, Sherry Y.

    2016-01-01

    Handheld devices are widely applied to support open and distributed learning, where students are diverse. On the other hand, customization and personalization can be applied to accommodate students' diversities. However, paucity of research compares the effects of customization and personalization in the context of handheld devices. To this end, a…

  14. Characterizing the reflectivity of handheld display devices.

    Science.gov (United States)

    Liu, Peter; Badano, Aldo

    2014-08-01

    With increased use of handheld and tablet display devices for viewing medical images, methods for consistently measuring reflectivity of the devices are needed. In this note, the authors report on the characterization of diffuse reflections for handheld display devices including mobile phones and tablets using methods recommended by the American Association of Physicists in Medicine Task Group 18 (TG18). The authors modified the diffuse reflectance coefficient measurement method outlined in the TG18 report. The authors measured seven handheld display devices (two phones and five tablets) and three workstation displays. The device was attached to a black panel with Velcro. To study the effect of the back surface on the diffuse reflectance coefficient, the authors created Styrofoam masks with different size square openings and placed it in front of the device. Overall, for each display device, measurements of illuminance and reflected luminance on the display screen were taken. The authors measured with no mask, with masks of varying size, and with display-size masks, and calculated the corresponding diffuse reflectance coefficient. For all handhelds, the diffuse reflectance coefficient measured with no back panel were lower than measurements performed with a mask. The authors found an overall increase in reflectivity as the size of the mask decreases. For workstations displays, diffuse reflectance coefficients were higher when no back panel was used, and higher than with masks. In all cases, as luminance increased, illuminance increased, but not at the same rate. Since the size of handheld displays is smaller than that of workstation devices, the TG18 method suffers from a dependency on illumination condition. The authors show that the diffuse reflection coefficients can vary depending on the nature of the back surface of the illuminating box. The variability in the diffuse coefficient can be as large as 20% depending on the size of the mask. For all measurements

  15. Driver hand-held cellular phone use: a four-year analysis.

    Science.gov (United States)

    Eby, David W; Vivoda, Jonathon M; St Louis, Renée M

    2006-01-01

    The use of hand-held cellular (mobile) phones while driving has stirred more debate, passion, and research than perhaps any other traffic safety issue in the past several years. There is ample research showing that the use of either hand-held or hands-free cellular phones can lead to unsafe driving patterns. Whether or not these performance deficits increase the risk of crash is difficult to establish, but recent studies are beginning to suggest that cellular phone use elevates crash risk. The purpose of this study was to assess changes in the rate of hand-held cellular phone use by motor-vehicle drivers on a statewide level in Michigan. This study presents the results of 13 statewide surveys of cellular phone use over a 4-year period. Hand-held cellular phone use data were collected through direct observation while vehicles were stopped at intersections and freeway exit ramps. Data were weighted to be representative of all drivers traveling during daylight hours in Michigan. The study found that driver hand-held cellular phone use has more than doubled between 2001 and 2005, from 2.7% to 5.8%. This change represents an average increase of 0.78 percentage points per year. The 5.8% use rate observed in 2005 means that at any given daylight hour, around 36,550 drivers were conversing on cellular phones while driving on Michigan roadways. The trend line fitted to these data predicts that by the year 2010, driver hand-held cellular phone use will be around 8.6%, or 55,000 drivers at any given daylight hour. These results make it clear that cellular phone use while driving will continue to be an important traffic safety issue, and highlight the importance of continued attempts to generate new ways of alleviating this potential hazard.

  16. Potential role of a new hand-held miniature gamma camera in performing minimally invasive parathyroidectomy

    Energy Technology Data Exchange (ETDEWEB)

    Ortega, Joaquin; Lledo, Salvador [University of Valencia, Clinic University Hospital, Department of Surgery, Valencia (Spain); Ferrer-Rebolleda, Jose [Clinic University Hospital, Department of Nuclear Medicine, Valencia (Spain); Cassinello, Norberto [Clinic University Hospital, Unit of Endocrinologic and Bariatric Surgery, Valencia (Spain)

    2007-02-15

    Sestamibi scans have increased the use of minimally invasive parathyroidectomy (MIP) to treat primary hyperparathyroidism (PHPT) when caused by a parathyroid single adenoma. The greatest concern for surgeons remains the proper identification of pathological glands in a limited surgical field. We have studied the usefulness of a new hand-held miniature gamma camera (MGC) when used intraoperatively to locate parathyroid adenomas. To our knowledge this is the first report published on this subject in the scientific literature. Five patients with PHPT secondary to a single adenoma, positively diagnosed by preoperative sestamibi scans, underwent a MIP. A gamma probe for radioguided surgery and the new hand-held MGC were used consecutively to locate the pathological glands. This new MGC has a module composed of a high-resolution interchangeable collimator and a CsI(Na) scintillating crystal. It has dimensions of around 15 cm x 8 cm x 9 cm and weighs 1 kg. The intraoperative assay of PTH (ioPTH) was used to confirm the complete resection of pathological tissue. All cases were operated on successfully by a MIP. The ioPTH confirmed the excision of all pathological tissues. The MGC proved its usefulness in all patients, even in a difficult case in which the first attempt with the gamma probe failed. In all cases it offered real-time accurate intraoperative images. The hand-held MGC is a useful instrument in MIP for PHPT. It may be used to complement the standard tools used to date, or may even replace them, at least in selected cases of single adenomas. (orig.)

  17. Potential role of a new hand-held miniature gamma camera in performing minimally invasive parathyroidectomy

    International Nuclear Information System (INIS)

    Ortega, Joaquin; Lledo, Salvador; Ferrer-Rebolleda, Jose; Cassinello, Norberto

    2007-01-01

    Sestamibi scans have increased the use of minimally invasive parathyroidectomy (MIP) to treat primary hyperparathyroidism (PHPT) when caused by a parathyroid single adenoma. The greatest concern for surgeons remains the proper identification of pathological glands in a limited surgical field. We have studied the usefulness of a new hand-held miniature gamma camera (MGC) when used intraoperatively to locate parathyroid adenomas. To our knowledge this is the first report published on this subject in the scientific literature. Five patients with PHPT secondary to a single adenoma, positively diagnosed by preoperative sestamibi scans, underwent a MIP. A gamma probe for radioguided surgery and the new hand-held MGC were used consecutively to locate the pathological glands. This new MGC has a module composed of a high-resolution interchangeable collimator and a CsI(Na) scintillating crystal. It has dimensions of around 15 cm x 8 cm x 9 cm and weighs 1 kg. The intraoperative assay of PTH (ioPTH) was used to confirm the complete resection of pathological tissue. All cases were operated on successfully by a MIP. The ioPTH confirmed the excision of all pathological tissues. The MGC proved its usefulness in all patients, even in a difficult case in which the first attempt with the gamma probe failed. In all cases it offered real-time accurate intraoperative images. The hand-held MGC is a useful instrument in MIP for PHPT. It may be used to complement the standard tools used to date, or may even replace them, at least in selected cases of single adenomas. (orig.)

  18. Pyxis handheld polarimetric imager

    Science.gov (United States)

    Chenault, David B.; Pezzaniti, J. Larry; Vaden, Justin P.

    2016-05-01

    The instrumentation for measuring infrared polarization signatures has seen significant advancement over the last decade. Previous work has shown the value of polarimetric imagery for a variety of target detection scenarios including detection of manmade targets in clutter and detection of ground and maritime targets while recent work has shown improvements in contrast for aircraft detection and biometric markers. These data collection activities have generally used laboratory or prototype systems with limitations on the allowable amount of target motion or the sensor platform and usually require an attached computer for data acquisition and processing. Still, performance and sensitivity have been steadily getting better while size, weight, and power requirements have been getting smaller enabling polarimetric imaging for a greater or real world applications. In this paper, we describe Pyxis®, a microbolometer based imaging polarimeter that produces live polarimetric video of conventional, polarimetric, and fused image products. A polarization microgrid array integrated in the optical system captures all polarization states simultaneously and makes the system immune to motion artifacts of either the sensor or the scene. The system is battery operated, rugged, and weighs about a quarter pound, and can be helmet mounted or handheld. On board processing of polarization and fused image products enable the operator to see polarimetric signatures in real time. Both analog and digital outputs are possible with sensor control available through a tablet interface. A top level description of Pyxis® is given followed by performance characteristics and representative data.

  19. 75 FR 27504 - Substantial Product Hazard List: Hand-Held Hair Dryers

    Science.gov (United States)

    2010-05-17

    ... immersion during their use. Section 15(a) of the CPSA defines ``substantial product hazard'' to include, a....'' Hand-held hair dryers routinely contain open-coil heating elements that are, in essence, uninsulated..., bathtub, or lavatory). The proposed rule would define ``hand-held hair dryer'' as ``an electrical...

  20. Prospective evaluation of an internet-linked handheld computer critical care knowledge access system.

    Science.gov (United States)

    Lapinsky, Stephen E; Wax, Randy; Showalter, Randy; Martinez-Motta, J Carlos; Hallett, David; Mehta, Sangeeta; Burry, Lisa; Stewart, Thomas E

    2004-12-01

    Critical care physicians may benefit from immediate access to medical reference material. We evaluated the feasibility and potential benefits of a handheld computer based knowledge access system linking a central academic intensive care unit (ICU) to multiple community-based ICUs. Four community hospital ICUs with 17 physicians participated in this prospective interventional study. Following training in the use of an internet-linked, updateable handheld computer knowledge access system, the physicians used the handheld devices in their clinical environment for a 12-month intervention period. Feasibility of the system was evaluated by tracking use of the handheld computer and by conducting surveys and focus group discussions. Before and after the intervention period, participants underwent simulated patient care scenarios designed to evaluate the information sources they accessed, as well as the speed and quality of their decision making. Participants generated admission orders during each scenario, which were scored by blinded evaluators. Ten physicians (59%) used the system regularly, predominantly for nonmedical applications (median 32.8/month, interquartile range [IQR] 28.3-126.8), with medical software accessed less often (median 9/month, IQR 3.7-13.7). Eight out of 13 physicians (62%) who completed the final scenarios chose to use the handheld computer for information access. The median time to access information on the handheld handheld computer was 19 s (IQR 15-40 s). This group exhibited a significant improvement in admission order score as compared with those who used other resources (P = 0.018). Benefits and barriers to use of this technology were identified. An updateable handheld computer system is feasible as a means of point-of-care access to medical reference material and may improve clinical decision making. However, during the study, acceptance of the system was variable. Improved training and new technology may overcome some of the barriers we

  1. An Investigation of Game-Embedded Handheld Devices to Enhance English Learning

    Science.gov (United States)

    Hung, Hui-Chun; Young, Shelley Shwu-Ching

    2015-01-01

    This study proposed and implemented a system combining the advantages of both educational games and wireless handheld technology to promote the interactive English learning in the classroom setting. An interactive English vocabulary acquisition board game was designed with the system being implemented on handheld devices. Thirty sixth-grade…

  2. Decisions at hand: a decision support system on handhelds.

    Science.gov (United States)

    Zupan, B; Porenta, A; Vidmar, G; Aoki, N; Bratko, I; Beck, J R

    2001-01-01

    One of the applications of clinical information systems is decision support. Although the advantages of utilizing such aids have never been theoretically disputed, they have been rarely used in practice. The factor that probably often limits the utility of clinical decision support systems is the need for computing power at the very site of decision making--at the place where the patient is interviewed, in discussion rooms, etc. The paper reports on a possible solution to this problem. A decision-support shell LogReg is presented, which runs on a handheld computer. A general schema for handheld-based decision support is also proposed, where decision models are developed on personal computers/workstations, encoded in XML and then transferred to handhelds, where the models are used within a decision support shell. A use case where LogReg has been applied to clinical outcome prediction in crush injury is presented.

  3. Using medical knowledge sources on handheld computers--a qualitative study among junior doctors.

    Science.gov (United States)

    Axelson, Christian; Wårdh, Inger; Strender, Lars-Erik; Nilsson, Gunnar

    2007-09-01

    The emergence of mobile computing could have an impact on how junior doctors learn. To exploit this opportunity it is essential to understand their information seeking process. To explore junior doctors' experiences of using medical knowledge sources on handheld computers. Interviews with five Swedish junior doctors. A qualitative manifest content analysis of a focus group interview followed by a qualitative latent content analysis of two individual interviews. A focus group interview showed that users were satisfied with access to handheld medical knowledge sources, but there was concern about contents, reliability and device dependency. Four categories emerged from individual interviews: (1) A feeling of uncertainty about using handheld technology in medical care; (2) A sense of security that handhelds can provide; (3) A need for contents to be personalized; (4) A degree of adaptability to make the handheld a versatile information tool. A theme was established to link the four categories together, as expressed in the Conclusion section. Junior doctors' experiences of using medical knowledge sources on handheld computers shed light on the need to decrease uncertainty about clinical decisions during medical internship, and to find ways to influence the level of self-confidence in the junior doctor's process of decision-making.

  4. Status report on the TSA Systems, Ltd., MCA465 gamma-ray confirmation instrument

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Rutherford, D.A.

    1994-01-01

    The TSA Systems, Ltd., MCA465 is hand-portable, low resolution, gamma-ray instrument for confirming special nuclear materials (SNM) and related applications. The instrument evolved from earlier TSA Systems hand-held instruments, and, since its inception in 1991, it has been undergoing cycles of evaluation and then repair or redesign to correct problems. Through the efforts of Los Alamos, Rocky Flats, and TSA Systems, the MCA465 now has achieved commendable progress toward achieving quality performance as a rapid confirmation tool for SNM

  5. Augmented Reality Simulations on Handheld Computers

    Science.gov (United States)

    Squire, Kurt; Klopfer, Eric

    2007-01-01

    Advancements in handheld computing, particularly its portability, social interactivity, context sensitivity, connectivity, and individuality, open new opportunities for immersive learning environments. This article articulates the pedagogical potential of augmented reality simulations in environmental engineering education by immersing students in…

  6. Texting while driving: is speech-based text entry less risky than handheld text entry?

    Science.gov (United States)

    He, J; Chaparro, A; Nguyen, B; Burge, R J; Crandall, J; Chaparro, B; Ni, R; Cao, S

    2014-11-01

    Research indicates that using a cell phone to talk or text while maneuvering a vehicle impairs driving performance. However, few published studies directly compare the distracting effects of texting using a hands-free (i.e., speech-based interface) versus handheld cell phone, which is an important issue for legislation, automotive interface design and driving safety training. This study compared the effect of speech-based versus handheld text entries on simulated driving performance by asking participants to perform a car following task while controlling the duration of a secondary text-entry task. Results showed that both speech-based and handheld text entries impaired driving performance relative to the drive-only condition by causing more variation in speed and lane position. Handheld text entry also increased the brake response time and increased variation in headway distance. Text entry using a speech-based cell phone was less detrimental to driving performance than handheld text entry. Nevertheless, the speech-based text entry task still significantly impaired driving compared to the drive-only condition. These results suggest that speech-based text entry disrupts driving, but reduces the level of performance interference compared to text entry with a handheld device. In addition, the difference in the distraction effect caused by speech-based and handheld text entry is not simply due to the difference in task duration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Development of Real-Time Dual-Display Handheld and Bench-Top Hybrid-Mode SD-OCTs

    Directory of Open Access Journals (Sweden)

    Nam Hyun Cho

    2014-01-01

    Full Text Available Development of a dual-display handheld optical coherence tomography (OCT system for retina and optic-nerve-head diagnosis beyond the volunteer motion constraints is reported. The developed system is portable and easily movable, containing the compact portable OCT system that includes the handheld probe and computer. Eye posterior chambers were diagnosed using the handheld probe, and the probe could be fixed to the bench-top cradle depending on the volunteers’ physical condition. The images obtained using this handheld probe were displayed in real time on the computer monitor and on a small secondary built-in monitor; the displayed images were saved using the handheld probe’s built-in button. Large-scale signal-processing procedures such as k-domain linearization, fast Fourier transform (FFT, and log-scaling signal processing can be rapidly applied using graphics-processing-unit (GPU accelerated processing rather than central-processing-unit (CPU processing. The Labview-based system resolution is 1,024 × 512 pixels, and the frame rate is 56 frames/s, useful for real-time display. The 3D images of the posterior chambers including the retina, optic-nerve head, blood vessels, and optic nerve were composed using real-time displayed images with 500 × 500 × 500 pixel resolution. A handheld and bench-top hybrid mode with a dual-display handheld OCT was developed to overcome the drawbacks of the conventional method.

  8. Improving car passengers' comfort and experience by supporting the use of handheld devices.

    Science.gov (United States)

    van Veen, S A T; Hiemstra-van Mastrigt, S; Kamp, I; Vink, P

    2014-01-01

    There is a demand for interiors to support other activities in a car than controlling the vehicle. Currently, this is the case for the car passengers and--in the future--autonomous driving cars will also facilitate drivers to perform other activities. One of these activities is working with handheld devices. Previous research shows that people experience problems when using handheld devices in a moving vehicle and the use of handheld devices generally causes unwanted neck flexion [Young et al. 2012; Sin and Zu 2011; Gold et al.2011]. In this study, armrests are designed to support the arms when using handheld devices in a driving car in order to decrease neck flexion. Neck flexion was measured by attaching markers on the C7 and tragus. Discomfort was indicated on a body map on a scale 1-10. User experience was evaluated in a semi-structured interview. Neck flexion is significantly decreased by the support of the armrests and approaches a neutral position. Furthermore, overall comfort and comfort in the neck region specifically are significantly increased. Subjects appreciate the body posture facilitated by the armrests and 9 out of 10 prefer using handheld devices with the armrests compared to using handheld devices without the armrests. More efforts are needed to develop the mock-up into an established product, but the angles and dimensions presented in this study could serve as guidelines.

  9. Ultrasonography with a hand-held device for the diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Kameda, Toru; Takahashi, Isao

    2009-01-01

    The purpose of this study was to evaluate the accuracy of ultrasonography (US) with a hand-held device for the diagnosis of acute appendicitis in the emergency room. US with a hand-held device was performed by the first author in 33 patients suspected of having appendicitis in the emergency room. From these 33 patients, 24 who subsequently underwent computed tomography (CT) or surgery were included in this study. The accuracy of US with the hand-held device for the diagnosis of acute appendicitis was evaluated based on the findings of CT or surgery. CT and surgery were performed in 22 and 12 patients, respectively. Final diagnoses were acute appendicitis (n=18), terminal ileitis (n=2), pelvic inflammatory disease (n=2), diverticulitis (n=1), and ureterolithiasis (n=1). The US yielded a sensitivity of 78% and a positive predictive value of 100%. The shortest distance between the abdominal wall and the appendix measured on CT was less than 40 mm in 11 patients. In ten (91%) of the 11 patients US with the hand-held device showed the swollen appendix. US with a hand-held device is potentially useful in the positive identification of acute appendicitis, but further investigation is needed to prove its utility in the routine diagnosis of acute appendicitis. (author)

  10. Introducing handheld computing into a residency program: preliminary results from qualitative and quantitative inquiry.

    OpenAIRE

    Manning, B.; Gadd, C. S.

    2001-01-01

    Although published reports describe specific handheld computer applications in medical training, we know very little yet about how, and how well, handheld computing fits into the spectrum of information resources available for patient care and physician training. This paper reports preliminary quantitative and qualitative results from an evaluation study designed to track changes in computer usage patterns and computer-related attitudes before and after introduction of handheld computing. Pre...

  11. Phonation Quotient in Women: A Measure of Vocal Efficiency Using Three Aerodynamic Instruments.

    Science.gov (United States)

    Joshi, Ashwini; Watts, Christopher R

    2017-03-01

    The purpose of this study was to examine measures of vital capacity and phonation quotient across three age groups in women using three different aerodynamic instruments representing low-tech and high-tech options. This study has a prospective, repeated measures design. Fifteen women in each age group of 25-39 years, 40-59 years, and 60-79 years were assessed using maximum phonation time and vital capacity obtained from three aerodynamic instruments: a handheld analog windmill type spirometer, a handheld digital spirometer, and the Phonatory Aerodynamic System (PAS), Model 6600. Phonation quotient was calculated using vital capacity from each instrument. Analyses of variance were performed to test for main effects of the instruments and age on vital capacity and derived phonation quotient. Pearson product moment correlation was performed to assess measurement reliability (parallel forms) between the instruments. Regression equations, scatterplots, and coefficients of determination were also calculated. Statistically significant differences were found in vital capacity measures for the digital spirometer compared with the windmill-type spirometer and PAS across age groups. Strong positive correlations were present between all three instruments for both vital capacity and derived phonation quotient measurements. Measurement precision for the digital spirometer was lower than the windmill spirometer compared with the PAS. However, all three instruments had strong measurement reliability. Additionally, age did not have an effect on the measurement across instruments. These results are consistent with previous literature reporting data from male speakers and support the use of low-tech options for measurement of basic aerodynamic variables associated with voice production. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  12. 40 CFR 90.129 - Fuel tank permeation from handheld engines and equipment.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Fuel tank permeation from handheld... KILOWATTS Emission Standards and Certification Provisions § 90.129 Fuel tank permeation from handheld... equipment with respect to fuel tanks. For the purposes of this section, fuel tanks do not include fuel caps...

  13. The use of handheld radiometry for the identification of stratigraphic characteristics of Paraiba Basin units

    International Nuclear Information System (INIS)

    Souza, Ebenezer Moreno de; Villar, Heldio Pereira; Lima, Ricardo de Andrade; Lima Filho, Mario

    2000-01-01

    A study on the use of radiometric techniques for the identification of stratigraphic characteristics of Paraiba Basin units was carried out with handheld instrumentation. The area chosen ran from north Pernambuco to south Paraiba. The presence of radioactive material had been previously determined. For this work a portable scintillometer was fixed to the door of a vehicle, on the outside, with the probe directed downwards. Background radiation was measured as 40 cps (counts per second). The scintillometer has an alarm which sounds whenever the measured count rate rises above a pre-established figure, 100 cps in the present case. Monitoring then proceeded manually. In sites where the count rate was much higher than 100 cps, the probe was lowered to the soil surface. Local coordinates were obtained by GPS. Therefore, an isoradioactivity map of the area could be drawn. The comparison between this map and local geological charts showed significant correlation between observed count rates and geologic formations. Low count rates were indicative of the Barreiras formation, whereas the highest rates were obtained for the Gramame formation (with urano-phosphatic lythotypes). It is concluded that handheld radiometry is a useful tool in geological charting, is special in areas where stratigraphic units have been masked by environmental changes and human activities. (author)

  14. Fusing Open Source Intelligence and Handheld Situational Awareness - Benghazi Case Study

    Science.gov (United States)

    2014-10-01

    1 DM-0001694 Fusing Open Source Intelligence and Handheld Situational Awareness Benghazi Case Study Jeff Boleng, PhD Marc Novakouski Gene...command and control element at the CIA compound that would have been monitoring OSINT and other sources of intelligence before the attack and... Source Intelligence and Handheld Situational Awareness - Benghazi Case Study 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6

  15. Handheld computers in nursing education: PDA pilot project.

    Science.gov (United States)

    Koeniger-Donohue, Rebecca

    2008-02-01

    Interest in the use and application of handheld technology at undergraduate and graduate nursing programs across the country is growing rapidly. Personal digital assistants (PDAs) are often referred to as a "peripheral brain" because they can save time, decrease errors, and simplify information retrieval at the point of care. In addition, research results support the notion that PDAs enhance nursing clinical education and are an effective student learning resource. However, most nursing programs lack the full range of technological resources to implement and provide ongoing support for handheld technology use by faculty and students. This article describes a 9-month pilot project for the initial use of PDAs by novice faculty and students at Simmons College.

  16. Applicability of a Diffuse Reflectance Infrared Fourier Transform handheld spectrometer to perform in situ analyses on Cultural Heritage materials.

    Science.gov (United States)

    Arrizabalaga, Iker; Gómez-Laserna, Olivia; Aramendia, Julene; Arana, Gorka; Madariaga, Juan Manuel

    2014-08-14

    This work studies the applicability of a Diffuse Reflectance Infrared Fourier Transform handheld device to perform in situ analyses on Cultural Heritage assets. This portable diffuse reflectance spectrometer has been used to characterise and diagnose the conservation state of (a) building materials of the Guevara Palace (15th century, Segura, Basque Country, Spain) and (b) different 19th century wallpapers manufactured by the Santa Isabel factory (Vitoria-Gasteiz, Basque Country, Spain) and by the well known Dufour and Leroy manufacturers (Paris, France), all of them belonging to the Torre de los Varona Castle (Villanañe, Basque Country, Spain). In all cases, in situ measurements were carried out and also a few samples were collected and measured in the laboratory by diffuse reflectance spectroscopy (DRIFT) in order to validate the information obtained by the handheld instrument. In the analyses performed in situ, distortions in the diffuse reflectance spectra can be observed due to the presence of specular reflection, showing the inverted bands caused by the Reststrahlen effect, in particular on those IR bands with the highest absorption coefficients. This paper concludes that the results obtained in situ by a diffuse reflectance handheld device are comparable to those obtained with laboratory diffuse reflectance spectroscopy equipment and proposes a few guidelines to acquire good spectra in the field, minimising the influence caused by the specular reflection. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Handheld Multi-Gas Meters Market Survey Report

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Gustavious [Brigham Young Univ., Provo, UT (United States); Wald-Hopkins, Mark David [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Obrey, Stephen J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Akhadov, Valida Dushdurova [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-23

    Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the chemical monitored. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. To provide emergency responders with information on handheld multi-gas meters, the System Assessment and Validation for Emergency Responders (SAVER) Program conducted a market survey. This market survey report is based on information gathered between November 2015 and February 2016 from vendors, Internet research, industry publications, an emergency responder focus group, and a government issued Request for Information (RFI) that was posted on the Federal Business Opportunities website.

  18. Who’s That Girl? Handheld Augmented Reality for Printed Photo Books

    OpenAIRE

    Henze , Niels; Boll , Susanne

    2011-01-01

    Part 1: Long and Short Papers; International audience; Augmented reality on mobile phones has recently made major progress. Lightweight, markerless object recognition and tracking makes handheld Augmented Reality feasible for new application domains. As this field is technology driven the interface design has mostly been neglected. In this paper we investigate visualization techniques for augmenting printed documents using handheld Augmented Reality. We selected the augmentation of printed ph...

  19. Energy Cost of Active and Sedentary Music Video Games: Drum and Handheld Gaming vs. Walking and Sitting.

    Science.gov (United States)

    Miranda, Edwin; Overstreet, Brittany S; Fountain, William A; Gutierrez, Vincent; Kolankowski, Michael; Overstreet, Matthew L; Sapp, Ryan M; Wolff, Christopher A; Mazzetti, Scott A

    2017-01-01

    To compare energy expenditure during and after active and handheld video game drumming compared to walking and sitting. Ten experienced, college-aged men performed four protocols (one per week): no-exercise seated control (CTRL), virtual drumming on a handheld gaming device (HANDHELD), active drumming on drum pads (DRUM), and walking on a treadmill at ~30% of VO 2max (WALK). Protocols were performed after an overnight fast, and expired air was collected continuously during (30min) and after (30min) exercise. DRUM and HANDHELD song lists, day of the week, and time of day were identical for each participant. Significant differences (p DRUM > HANDHELD. No significant differences in the rates of energy expenditure among groups during recovery were observed. Total energy expenditure was significantly greater (p < 0.05) during WALK (149.5 ± 30.6 kcal) compared to DRUM (118.7 ± 18.8 kcal) and HANDHELD (44.9±11.6 kcal), and greater during DRUM compared to HANDHELD. Total energy expenditure was not significantly different between HANDHELD (44.9 ± 11.6 kcal) and CTRL (38.2 ± 6.0 kcal). Active video game drumming at expert-level significantly increased energy expenditure compared to handheld, but it hardly met moderate-intensity activity standards, and energy expenditure was greatest during walking. Energy expenditure with handheld video game drumming was not different from no-exercise control. Thus, traditional aerobic exercise remains at the forefront for achieving the minimum amount and intensity of physical activity for health, individuals desiring to use video games for achieving weekly physical activity recommendations should choose games that require significant involvement of lower-body musculature, and time spent playing sedentary games should be a limited part of an active lifestyle.

  20. Handheld single photon emission computed tomography (handheld SPECT) navigated video-assisted thoracoscopic surgery of computer tomography-guided radioactively marked pulmonary lesions.

    Science.gov (United States)

    Müller, Joachim; Putora, Paul Martin; Schneider, Tino; Zeisel, Christoph; Brutsche, Martin; Baty, Florent; Markus, Alexander; Kick, Jochen

    2016-09-01

    Radioactive marking can be a valuable extension to minimally invasive surgery. The technique has been clinically applied in procedures involving sentinel lymph nodes, parathyroidectomy as well as interventions in thoracic surgery. Improvements in equipment and techniques allow one to improve the limits. Pulmonary nodules are frequently surgically removed for diagnostic or therapeutic reasons; here video-assisted thoracoscopic surgery (VATS) is the preferred technique. VATS might be impossible with nodules that are small or located deep in the lung. In this study, we examined the clinical application and safety of employing the newly developed handheld single photon emission tomography (handheld SPECT) device in combination with CT-guided radioactive marking of pulmonary nodules. In this pilot study, 10 subjects requiring surgical resection of a pulmonary nodule were included. The technique involved CT-guided marking of the target nodule with a 20-G needle, with subsequent injection of 25-30 MBq (effective: 7-14 MBq) Tc-99m MAA (Macro Albumin Aggregate). Quality control was made with conventional SPECT-CT to confirm the correct localization and exclude possible complications related to the puncture procedure. VATS was subsequently carried out using the handheld SPECT to localize the radioactivity intraoperatively and therefore the target nodule. A 3D virtual image was superimposed on the intraoperative visual image for surgical guidance. In 9 of the 10 subjects, the radioactive application was successfully placed directly in or in the immediate vicinity of the target nodule. The average size of the involved nodules was 9 mm (range 4-15). All successfully marked nodules were subsequently completely excised (R0) using VATS. The procedure was well tolerated. An asymptomatic clinically insignificant pneumothorax occurred in 5 subjects. Two subjects were found to have non-significant discrete haemorrhage in the infiltration canal of the needle. In a single subject, the

  1. Position statement on use of hand-held portable dental X-ray equipment

    International Nuclear Information System (INIS)

    2014-06-01

    The position statement focuses on justification in the medical field, in particular on the use of hand-held portable dental x-ray equipment. It supplements another HERCA position paper, providing a general overview of the use of all hand-held portable X-ray equipment. Key Messages: - HERCA finds that the use of hand-held portable X-ray devices should be discouraged except in special circumstances. - As a general rule, these devices should only be used in scenarios where an intraoral radiograph is deemed necessary for a patient and the use of a fixed or semi-mobile x-ray unit is impractical, e.g.: - nursing homes, residential care facilities or homes for persons with disabilities; - forensic odontology, - military operations abroad without dental facilities

  2. Carbonaceous species emitted from handheld two-stroke engines

    Science.gov (United States)

    Volckens, John; Olson, David A.; Hays, Michael D.

    Small, handheld two-stroke engines used for lawn and garden work (e.g., string trimmers, leaf blowers, etc.) can emit a variety of potentially toxic carbonaceous air pollutants. Yet, the emissions effluents from these machines go largely uncharacterized, constraining the proper development of human exposure estimates, emissions inventories, and climate and air quality models. This study samples and evaluates chemical pollutant emissions from the dynamometer testing of six small, handheld spark-ignition engines—model years 1998-2002. Four oil-gas blends were tested in each engine in duplicate. Emissions of carbon dioxide, carbon monoxide, and gas-phase hydrocarbons were predominant, and the PM emitted was organic matter primarily. An ANOVA model determined that engine type and control tier contributed significantly to emissions variations across all identified compound classes; whereas fuel blend was an insignificant variable accounting for engines were generally intermediate in magnitude compared with other gasoline-powered engines, numerous compounds traditionally viewed as motor vehicle markers are also present in small engine emissions in similar relative proportions. Given that small, handheld two-stroke engines used for lawn and garden work account for 5-10% of total US emissions of CO, CO 2, NO x, HC, and PM 2.5, source apportionment models and human exposure studies need to consider the effect of these small engines on ambient concentrations in air polluted environments.

  3. A smartphone controlled handheld microfluidic liquid handling system.

    Science.gov (United States)

    Li, Baichen; Li, Lin; Guan, Allan; Dong, Quan; Ruan, Kangcheng; Hu, Ronggui; Li, Zhenyu

    2014-10-21

    Microfluidics and lab-on-a-chip technologies have made it possible to manipulate small volume liquids with unprecedented resolution, automation and integration. However, most current microfluidic systems still rely on bulky off-chip infrastructures such as compressed pressure sources, syringe pumps and computers to achieve complex liquid manipulation functions. Here, we present a handheld automated microfluidic liquid handling system controlled by a smartphone, which is enabled by combining elastomeric on-chip valves and a compact pneumatic system. As a demonstration, we show that the system can automatically perform all the liquid handling steps of a bead-based HIV1 p24 sandwich immunoassay on a multi-layer PDMS chip without any human intervention. The footprint of the system is 6 × 10.5 × 16.5 cm, and the total weight is 829 g including battery. Powered by a 12.8 V 1500 mAh Li battery, the system consumed 2.2 W on average during the immunoassay and lasted for 8.7 h. This handheld microfluidic liquid handling platform is generally applicable to many biochemical and cell-based assays requiring complex liquid manipulation and sample preparation steps such as FISH, PCR, flow cytometry and nucleic acid sequencing. In particular, the integration of this technology with read-out biosensors may help enable the realization of the long-sought Tricorder-like handheld in vitro diagnostic (IVD) systems.

  4. Handheld low-temperature plasma probe for portable "point-and-shoot" ambient ionization mass spectrometry.

    Science.gov (United States)

    Wiley, Joshua S; Shelley, Jacob T; Cooks, R Graham

    2013-07-16

    We describe a handheld, wireless low-temperature plasma (LTP) ambient ionization source and its performance on a benchtop and a miniature mass spectrometer. The source, which is inexpensive to build and operate, is battery-powered and utilizes miniature helium cylinders or air as the discharge gas. Comparison of a conventional, large-scale LTP source against the handheld LTP source, which uses less helium and power than the large-scale version, revealed that the handheld source had similar or slightly better analytical performance. Another advantage of the handheld LTP source is the ability to quickly interrogate a gaseous, liquid, or solid sample without requiring any setup time. A small, 7.4-V Li-polymer battery is able to sustain plasma for 2 h continuously, while the miniature helium cylinder supplies gas flow for approximately 8 continuous hours. Long-distance ion transfer was achieved for distances up to 1 m.

  5. Validity of maximal isometric knee extension strength measurements obtained via belt-stabilized hand-held dynamometry in healthy adults.

    Science.gov (United States)

    Ushiyama, Naoko; Kurobe, Yasushi; Momose, Kimito

    2017-11-01

    [Purpose] To determine the validity of knee extension muscle strength measurements using belt-stabilized hand-held dynamometry with and without body stabilization compared with the gold standard isokinetic dynamometry in healthy adults. [Subjects and Methods] Twenty-nine healthy adults (mean age, 21.3 years) were included. Study parameters involved right side measurements of maximal isometric knee extension strength obtained using belt-stabilized hand-held dynamometry with and without body stabilization and the gold standard. Measurements were performed in all subjects. [Results] A moderate correlation and fixed bias were found between measurements obtained using belt-stabilized hand-held dynamometry with body stabilization and the gold standard. No significant correlation and proportional bias were found between measurements obtained using belt-stabilized hand-held dynamometry without body stabilization and the gold standard. The strength identified using belt-stabilized hand-held dynamometry with body stabilization may not be commensurate with the maximum strength individuals can generate; however, it reflects such strength. In contrast, the strength identified using belt-stabilized hand-held dynamometry without body stabilization does not reflect the maximum strength. Therefore, a chair should be used to stabilize the body when performing measurements of maximal isometric knee extension strength using belt-stabilized hand-held dynamometry in healthy adults. [Conclusion] Belt-stabilized hand-held dynamometry with body stabilization is more convenient than the gold standard in clinical settings.

  6. Handheld emissions detector (HED): overview and development

    Science.gov (United States)

    Valentino, George J.; Schimmel, David

    2009-05-01

    Nova Engineering, Cincinnati OH, a division of L-3 Communications (L-3 Nova), under the sponsorship of Program Manager Soldier Warrior (PM-SWAR), Fort Belvoir, VA, has developed a Soldier portable, light-weight, hand-held, geolocation sensor and processing system called the Handheld Emissions Detector (HED). The HED is a broadband custom receiver and processor that allows the user to easily sense, direction find, and locate a broad range of emitters in the user's surrounding area. Now in its second design iteration, the HED incorporates a set of COTS components that are complemented with L-3 Nova custom RF, power, digital, and mechanical components, plus custom embedded and application software. The HED user interfaces are designed to provide complex information in a readily-understandable form, thereby providing actionable results for operators. This paper provides, where possible, the top-level characteristics of the HED as well as the rationale behind its design philosophy along with its applications in both DOD and Commercial markets.

  7. Portable Hand-Held Electrochemical Sensor for the Transuranics

    Energy Technology Data Exchange (ETDEWEB)

    Dale D. Russell, William B. Knowlton, Ph.D.; Russel Hertzog, Ph.D

    2005-11-25

    sensitive detector for uranium. Millimeter scale electrodes, operated by a hand-held instrument assembled in this lab and operated in the voltammetric mode, were transported to the DOE-Nevada test site (Las Vegas, NV) where field detection and quantitation of plutonium, uranium, and a mixture of these two elements was also demonstrated. Several probe designs were prepared, built and tested including probes with movable protective windows. A miniature, battery powered potentiostat was designed, built and demonstrated for use in a hand-held field portable instrument. This work was performed largely by undergraduates who gained valuable research experience, and many of them have continued on to graduate schools. In addition, they all gained exposure to and appreciation for national security research, in particular non-proliferation research. Four graduate students participated and one earned the MS degree on this project.

  8. Safeguards instrument to monitor spent reactor fuel

    International Nuclear Information System (INIS)

    Nicholson, N.; Dowdy, E.J.; Holt, D.M.; Stump, C.

    1981-01-01

    A hand-held instrument for monitoring irradiated nuclear fuel inventories located in water-filled storage ponds has been developed. This instrument provides sufficient precise qualitative and quantitative information to be useful as a confirmatory technique to International Atomic Energy Agency inspectors, and is believed to be of potential use to nuclear fuel managers and to operators of spent-fuel storage facilities, both at reactor and away-from-reactor, and to operators of nuclear fuel reprocessing plants. Because the Cerenkov radiation glow can barely be seen by the unaided eye under darkened conditions, a night vision device is incorporated to aid the operator in locating the fuel assembly to be measured. Beam splitting optics placed in front of the image intensifier and a preset aperture select a predetermined portion of the observed scene for measurement of the light intensity using a photomultiplier (PM) tube and digital readout. The PM tube gain is adjusted by use of an internal optical reference source, providing long term repeatability and instrument-to-instrument cnsistency. Interchangeable lenses accommodate various viewing and measuring conditions

  9. Development and testing of a scale to assess physician attitudes about handheld computers with decision support.

    Science.gov (United States)

    Ray, Midge N; Houston, Thomas K; Yu, Feliciano B; Menachemi, Nir; Maisiak, Richard S; Allison, Jeroan J; Berner, Eta S

    2006-01-01

    The authors developed and evaluated a rating scale, the Attitudes toward Handheld Decision Support Software Scale (H-DSS), to assess physician attitudes about handheld decision support systems. The authors conducted a prospective assessment of psychometric characteristics of the H-DSS including reliability, validity, and responsiveness. Participants were 82 Internal Medicine residents. A higher score on each of the 14 five-point Likert scale items reflected a more positive attitude about handheld DSS. The H-DSS score is the mean across the fourteen items. Attitudes toward the use of the handheld DSS were assessed prior to and six months after receiving the handheld device. Cronbach's Alpha was used to assess internal consistency reliability. Pearson correlations were used to estimate and detect significant associations between scale scores and other measures (validity). Paired sample t-tests were used to test for changes in the mean attitude scale score (responsiveness) and for differences between groups. Internal consistency reliability for the scale was alpha = 0.73. In testing validity, moderate correlations were noted between the attitude scale scores and self-reported Personal Digital Assistant (PDA) usage in the hospital (correlation coefficient = 0.55) and clinic (0.48), p DSS scale was reliable, valid, and responsive. The scale can be used to guide future handheld DSS development and implementation.

  10. A handheld point-of-care genomic diagnostic system.

    Directory of Open Access Journals (Sweden)

    Frank B Myers

    Full Text Available The rapid detection and identification of infectious disease pathogens is a critical need for healthcare in both developed and developing countries. As we gain more insight into the genomic basis of pathogen infectivity and drug resistance, point-of-care nucleic acid testing will likely become an important tool for global health. In this paper, we present an inexpensive, handheld, battery-powered instrument designed to enable pathogen genotyping in the developing world. Our Microfluidic Biomolecular Amplification Reader (µBAR represents the convergence of molecular biology, microfluidics, optics, and electronics technology. The µBAR is capable of carrying out isothermal nucleic acid amplification assays with real-time fluorescence readout at a fraction of the cost of conventional benchtop thermocyclers. Additionally, the µBAR features cell phone data connectivity and GPS sample geotagging which can enable epidemiological surveying and remote healthcare delivery. The µBAR controls assay temperature through an integrated resistive heater and monitors real-time fluorescence signals from 60 individual reaction chambers using LEDs and phototransistors. Assays are carried out on PDMS disposable microfluidic cartridges which require no external power for sample loading. We characterize the fluorescence detection limits, heater uniformity, and battery life of the instrument. As a proof-of-principle, we demonstrate the detection of the HIV-1 integrase gene with the µBAR using the Loop-Mediated Isothermal Amplification (LAMP assay. Although we focus on the detection of purified DNA here, LAMP has previously been demonstrated with a range of clinical samples, and our eventual goal is to develop a microfluidic device which includes on-chip sample preparation from raw samples. The µBAR is based entirely around open source hardware and software, and in the accompanying online supplement we present a full set of schematics, bill of materials, PCB layouts

  11. Handheld Computers in Education: An Industry Perspective

    Science.gov (United States)

    van 't Hooft, Mark; Vahey, Philip

    2007-01-01

    Five representatives from the mobile computing industry provide their perspectives on handhelds in education. While some of their ideas differ, they all agree on the importance of staff development, appropriate curriculum development, and teacher support to create the kinds of personalized learning environments that mobile devices make possible.

  12. Handheld FRET-Aptamer Sensor for Water Safety, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Operational Technologies Corporation (OpTech) proposes to expand its current NASA Phase 2 SBIR handheld fluorometer and bone marker fluorescence resonance energy...

  13. SAFARI 2000 Atmospheric Aerosol Measurements, Hand-held Hazemeters, Zambia

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: In conjunction with the AERONET (AErosol RObotic NETwork) participation in SAFARI 2000, the USDA Forest Service deployed handheld hazemeters in western...

  14. Handheld readout electronics to fully exploit the particle discrimination capabilities of elpasolite scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Budden, B.S., E-mail: bbudden@lanl.gov [Intelligence and Space Research Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Stonehill, L.C.; Warniment, A.; Michel, J.; Storms, S.; Dallmann, N.; Coupland, D.D.S.; Stein, P.; Weller, S.; Borges, L.; Proicou, M.; Duran, G. [Intelligence and Space Research Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Kamto, J. [Intelligence and Space Research Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Electrical & Computer Engineering Department, Praire View A& M University, Prairie View, TX 77446 (United States)

    2015-09-21

    A new class of elpasolite scintillators has garnered recent attention due to the ability to perform as simultaneous gamma spectrometers and thermal neutron detectors. Such a dual-mode capability is made possible by pulse-shape discrimination (PSD), whereby the emission waveform profiles of gamma and neutron events are fundamentally unique. To take full advantage of these materials, we have developed the Compact Advanced Readout Electronics for Elpasolites (CAREE). This handheld instrument employs a multi-channel PSD-capable ASIC, custom micro-processor board, front-end electronics, power supplies, and a 2 in. photomultiplier tube for readout of the scintillator. The unit is highly configurable to allow for performance optimization amongst a wide sample of elpasolites which provide PSD in fundamentally different ways. We herein provide an introduction to elpasolites, then describe the motivation for the work, mechanical and electronic design, and preliminary performance results.

  15. SAFARI 2000 Atmospheric Aerosol Measurements, Hand-held Hazemeters, Zambia

    Data.gov (United States)

    National Aeronautics and Space Administration — In conjunction with the AERONET (AErosol RObotic NETwork) participation in SAFARI 2000, the USDA Forest Service deployed handheld hazemeters in western Zambia from...

  16. 75 FR 8400 - In the Matter of Certain Wireless Communications System Server Software, Wireless Handheld...

    Science.gov (United States)

    2010-02-24

    ... Communications System Server Software, Wireless Handheld Devices and Battery Packs; Notice of Investigation... within the United States after importation of certain wireless communications system server software... certain wireless communications system server software, wireless handheld devices or battery packs that...

  17. The impact of legislation in Ireland on handheld mobile phone use by drivers.

    LENUS (Irish Health Repository)

    O'Meara, M

    2008-01-01

    Under the Road Traffic Act, 2006 handheld mobile phone use whilst driving is an offence liable to a fine and penalty points. The aim of this study was to determine whether there has been a change in driver behaviour following the introduction of this legislation. This study found that 2.3% of drivers were still using a handheld mobile phone.

  18. Development of a portable ambient temperature radiometric assaying instrument

    International Nuclear Information System (INIS)

    Lavietes, A.D.; McQuaid, J.H.; Ruhter, W.D.; Paulus, T.J.

    1995-01-01

    There is a strong need for portable radiometric instrumentation that can accurately confirm the presence of nuclear materials and allow isotopic analysis of radionuclides in the field. To fulfill this need, the authors are developing a hand-held, non-cryogenic, low-power gamma- and X-ray measurement and analysis instrument that can both search and then accurately verify the presence of nuclear materials. The authors report on the use of cadmium zinc telluride detectors, signal processing electronics, and the new field-portable instrument based on the MicroNOMAD Multichannel Analyzer from EG and G ORTEC. They will also describe the isotopic analysis that allows uranium enrichment measurements to be made accurately in the field. The benefits of this work are realized in a wide spectrum of applications that include Arms Control, Nuclear Safeguards, Environmental Management, Emergency Response, and Treaty Verification

  19. 75 FR 36678 - In the Matter of Certain Authentication Systems, Including Software and Handheld Electronic...

    Science.gov (United States)

    2010-06-28

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-697] In the Matter of Certain Authentication Systems, Including Software and Handheld Electronic Devices; Notice of Commission Decision Not to... importation of certain authentication systems, including software and handheld electronic devices, by reason...

  20. Criteria for a comparative assessment on handheld gamma-ray measurement tools

    International Nuclear Information System (INIS)

    Feichtinger, J.; Schwaiger, M.; Schmitzer, C.; Kindl, P.

    2001-01-01

    Full text: The radionuclide laboratories at the Austrian Research Centres Seibersdorf are strongly involved in radiation protection of public and employees as well as in environmental monitoring with special concern to gamma spectrometric measurements. Hence, field measurements and therefore the subject of hand-held measurement devices is a topic of main interest. Taking into consideration, that these hand-held measurement tool are further used in critical and sensitive operations, as for example by the IAEA Safeguards or by CTBTO On-Site inspectors, a standard for characterising these gamma measurement tools seems to be sound as necessary. The poster presents a set of technical criteria as well as limiting values, which allows an objective comparison of hand-held measurement devices. The criteria can be divided into three individual parts: radiometric characteristics, ergonomics and usability in field operations. The main criteria for testing the radiometry performance of hand-held measurement devices are sensitivity, efficiency, energy response, energy resolution and nuclide identification or not identification (if necessary), detection probability, dose rate indication, uncertainty, etc. The ergonomic test contains as dominating parts handling and quality of the manual. To evaluate the applicability in field operations different environmental conditions (e.g. light conditions, temperature range, moisture...) as well as battery lifetime and weight should be taken into account. These criteria may vary in dependence of the requirements or limitations given by various external conditions, but still a standard to evaluate and will give the opportunity to provide an objective comparison. (author)

  1. My-Mini-Pet: A Handheld Pet-Nurturing Game to Engage Students in Arithmetic Practices

    Science.gov (United States)

    Liao, C. C. Y.; Chen, Z-H.; Cheng, H. N. H.; Chen, F-C.; Chan, T-W.

    2011-01-01

    In the last decade, more and more games have been developed for handheld devices. Furthermore, the popularity of handheld devices and increase of wireless computing can be taken advantage of to provide students with more learning opportunities. Games also could bring promising benefits--specifically, motivating students to learn/play, sustaining…

  2. Hand-held cell phone use while driving legislation and observed driver behavior among population sub-groups in the United States.

    Science.gov (United States)

    Rudisill, Toni M; Zhu, Motao

    2017-05-12

    Cell phone use behaviors are known to vary across demographic sub-groups and geographic locations. This study examined whether universal hand-held calling while driving bans were associated with lower road-side observed hand-held cell phone conversations across drivers of different ages (16-24, 25-59, ≥60 years), sexes, races (White, African American, or other), ruralities (suburban, rural, or urban), and regions (Northeast, Midwest, South, and West). Data from the 2008-2013 National Occupant Protection Use Survey were merged with states' cell phone use while driving legislation. The exposure was presence of a universal hand-held cell phone ban at time of observation. Logistic regression was used to assess the odds of drivers having a hand-held cell phone conversation. Sub-groups differences were assessed using models with interaction terms. When universal hand-held cell phone bans were effective, hand-held cell phone conversations were lower across all driver demographic sub-groups and regions. Sub-group differences existed among the sexes (p-value, phone bans, the adjusted odds ratio (aOR) of a driver hand-held phone conversation was 0.34 [95% confidence interval (CI): 0.28, 0.41] for females versus 0.47 (CI 0.40, 0.55) for males and 0.31 (CI 0.25, 0.38) for drivers in Western states compared to 0.47 (CI 0.30, 0.72) in the Northeast and 0.50 (CI 0.38, 0.66) in the South. The presence of universal hand-held cell phone bans were associated lower hand-held cell phone conversations across all driver sub-groups and regions. Hand-held phone conversations were particularly lower among female drivers and those from Western states when these bans were in effect. Public health interventions concerning hand-held cell phone use while driving could reasonably target all drivers.

  3. Accentuated Factors of Handheld Computing

    DEFF Research Database (Denmark)

    Andersson, Bo; Henningsson, Stefan

    The recent years of rapid development of mobile technologies creates opportunities for new user-groups in the mobile workforce to take advantage of in-formation systems (IS). However, to apprehend and harness these opportunities for mobile IS it is crucial to fully understand the user group and t......, these two steps develop the framework towards a theoretical contribution as theory for describing handheld computing from a designer’s perspective. Thirteen semi-structured interviews were made and the tentative framework was elaborated and confirmed....

  4. Hand-held cell phone use while driving legislation and observed driver behavior among population sub-groups in the United States

    Directory of Open Access Journals (Sweden)

    Toni M. Rudisill

    2017-05-01

    Full Text Available Abstract Background Cell phone use behaviors are known to vary across demographic sub-groups and geographic locations. This study examined whether universal hand-held calling while driving bans were associated with lower road-side observed hand-held cell phone conversations across drivers of different ages (16–24, 25–59, ≥60 years, sexes, races (White, African American, or other, ruralities (suburban, rural, or urban, and regions (Northeast, Midwest, South, and West. Methods Data from the 2008–2013 National Occupant Protection Use Survey were merged with states’ cell phone use while driving legislation. The exposure was presence of a universal hand-held cell phone ban at time of observation. Logistic regression was used to assess the odds of drivers having a hand-held cell phone conversation. Sub-groups differences were assessed using models with interaction terms. Results When universal hand-held cell phone bans were effective, hand-held cell phone conversations were lower across all driver demographic sub-groups and regions. Sub-group differences existed among the sexes (p-value, <0.0001 and regions (p-value, 0.0003. Compared to states without universal hand-held cell phone bans, the adjusted odds ratio (aOR of a driver hand-held phone conversation was 0.34 [95% confidence interval (CI: 0.28, 0.41] for females versus 0.47 (CI 0.40, 0.55 for males and 0.31 (CI 0.25, 0.38 for drivers in Western states compared to 0.47 (CI 0.30, 0.72 in the Northeast and 0.50 (CI 0.38, 0.66 in the South. Conclusions The presence of universal hand-held cell phone bans were associated lower hand-held cell phone conversations across all driver sub-groups and regions. Hand-held phone conversations were particularly lower among female drivers and those from Western states when these bans were in effect. Public health interventions concerning hand-held cell phone use while driving could reasonably target all drivers.

  5. Acute pain management efficiency improves with point-of-care handheld electronic billing system.

    Science.gov (United States)

    Fahy, Brenda G

    2009-02-01

    Technology advances continue to impact patient care and physician workflow. To enable more efficient performance of billing activities, a point-of-care (POC) handheld computer technology replaced a paper-based system on an acute pain management service. Using a handheld personal digital assistant (PDA) and software from MDeverywhere (MDe, MDeverywhere, Long Island, NY), we performed a 1-yr prospective observational study of an anesthesiology acute pain management service billings and collections. Seventeen anesthesiologists providing billable acute pain services were trained and entered their charges on a PDA. Twelve months of data, just before electronic implementation (pre-elec), were compared to a 12-m period after implementation (post-elec). The total charges were 4883 for 890 patients pre-elec and 5368 for 1128 patients post-elec. With adoption of handheld billing, the charge lag days decreased from 29.3 to 7.0 (P billing using PDAs to replace a paper-based billing system improved the collection rate and decreased the number of charge lag days with a positive return on investment. The handheld PDA billing system provided POC support for physicians during their daily clinical (e.g., patient locations, rounding lists) and billing activities, improving workflow.

  6. Epilepsy Forewarning Using A Hand-Held Device

    Energy Technology Data Exchange (ETDEWEB)

    Hively, LM

    2005-02-21

    Over the last decade, ORNL has developed and patented a novel approach for forewarning of a large variety of machine and biomedical events. The present implementation uses desktop computers to analyze archival data. This report describes the next logical step in this effort, namely use of a hand-held device for the analysis.

  7. Clinical translation of handheld optical coherence tomography: practical considerations and recent advancements

    Science.gov (United States)

    Monroy, Guillermo L.; Won, Jungeun; Spillman, Darold R.; Dsouza, Roshan; Boppart, Stephen A.

    2017-12-01

    Since the inception of optical coherence tomography (OCT), advancements in imaging system design and handheld probes have allowed for numerous advancements in disease diagnostics and characterization of the structural and optical properties of tissue. OCT system developers continue to reduce form factor and cost, while improving imaging performance (speed, resolution, etc.) and flexibility for applicability in a broad range of fields, and nearly every clinical specialty. An extensive array of components to construct customized systems has also become available, with a range of commercial entities that produce high-quality products, from single components to full systems, for clinical and research use. Many advancements in the development of these miniaturized and portable systems can be linked back to a specific challenge in academic research, or a clinical need in medicine or surgery. Handheld OCT systems are discussed and explored for various applications. Handheld systems are discussed in terms of their relative level of portability and form factor, with mention of the supporting technologies and surrounding ecosystem that bolstered their development. Additional insight from our efforts to implement systems in several clinical environments is provided. The trend toward well-designed, efficient, and compact handheld systems paves the way for more widespread adoption of OCT into point-of-care or point-of-procedure applications in both clinical and commercial settings.

  8. Evaluation of an enclosed ultraviolet-C radiation device for decontamination of mobile handheld devices.

    Science.gov (United States)

    Mathew, J Itty; Cadnum, Jennifer L; Sankar, Thriveen; Jencson, Annette L; Kundrapu, Sirisha; Donskey, Curtis J

    2016-06-01

    Mobile handheld devices used in health care settings may become contaminated with health care-associated pathogens. We demonstrated that an enclosed ultraviolet-C radiation device was effective in rapidly reducing methicillin-resistant Staphylococcus aureus, and with longer exposure times, Clostridium difficile spores, on glass slides and reducing contamination on in-use mobile handheld devices. Published by Elsevier Inc.

  9. Agreement Between an Automated Volume Breast Scanner and Handheld Ultrasound for Diagnostic Breast Examinations.

    Science.gov (United States)

    Barr, Richard G; DeVita, Robert; Destounis, Stamatia; Manzoni, Federica; De Silvestri, Annalisa; Tinelli, Carmine

    2017-10-01

    To compare the agreement and interobserver variability of diagnostic handheld ultrasound (US) and a single volume on an automated breast volume scanner (ABVS) and to determine whether there was a significant difference if the ABVS was used by a sonographer or mammographic technologist. Ninety patients scheduled for diagnostic US examinations were randomized to either handheld US or the ABVS first. The AVBS was randomized between a sonographer and a mammographic technologist performing the study. The studies were blinded, randomized, and read by 2 radiologists. The lesion with the highest Breast Imaging Reporting and Data System (BI-RADS) score was used in the analysis. Final diagnoses were made by core biopsy or follow-up for 2 years. Lesions included 9 malignant and 81 benign. The 90 patients had a mean age ± SD of 53.1 ± 16.3 years. The κ value for agreement between the ABVS and handheld US was 0.831 (95% confidence interval, 0.744-0.925), whereas the global agreement for a 7-point BI-RADS score was 0.488 (0.372-0.560). The agreement between the ABVS and handheld US was nearly the same when the ABVS was used by a mammographic technologist (κ = 0.858 [0.723-0.963]) or sonographer (κ = 0.803 [0.596-1.000]; P = .47). The areas under the receiver operating characteristic curves for characterization by the ABVS were 0.91 (0.84-0.96) for reader 1 and 0.91 (0.83-0.96) for reader 2; those for handheld US were 0.91 (0.84-0.96) for reader 1 and 0.83 (0.74-0.90) for reader 2, with no statistical difference. The agreement based on pathologic images was κ = 0.831 (0.718-0.944); for handheld US, κ = 0.795 (0.623-0.967); and for the AVBS, κ = 0.869 (0.725-1.000). Performing a single-view diagnostic ABVS examination has good agreement with a handheld diagnostic US workup. There is no difference if the ABVS is used by a sonographer or mammographic technologist. © 2017 by the American Institute of Ultrasound in Medicine.

  10. Leakage and scattered radiation from hand-held dental x-ray unit

    International Nuclear Information System (INIS)

    Kim, Eun Kyung

    2007-01-01

    To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR ΙΙΙ was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of hand-held dental X-ray unit were 70 kVp, 3 mA , 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. The mean dose at the hand level when human skull DXTTR ΙΙΙ was exposed with portable X-ray unit 6.39 μGy, and the mean dose with fixed X-ray unit 3.03 μGy (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was 2.97 μGy and with fixed X-ray unit the mean dose was 0.68 μGy (p<0.01). The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography

  11. Leakage and scattered radiation from hand-held dental x-ray unit

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Kyung [Dankook Univ. School of Dentistry, Seoul (Korea, Republic of)

    2007-06-15

    To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR {iota}{iota}{iota} was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of hand-held dental X-ray unit were 70 kVp, 3 mA , 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. The mean dose at the hand level when human skull DXTTR {iota}{iota}{iota} was exposed with portable X-ray unit 6.39 {mu}Gy, and the mean dose with fixed X-ray unit 3.03 {mu}Gy (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was 2.97 {mu}Gy and with fixed X-ray unit the mean dose was 0.68 {mu}Gy (p<0.01). The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography.

  12. Handheld computers for self-administered sensitive data collection: A comparative study in Peru

    Directory of Open Access Journals (Sweden)

    Hughes James P

    2008-03-01

    Full Text Available Abstract Background Low-cost handheld computers (PDA potentially represent an efficient tool for collecting sensitive data in surveys. The goal of this study is to evaluate the quality of sexual behavior data collected with handheld computers in comparison with paper-based questionnaires. Methods A PDA-based program for data collection was developed using Open-Source tools. In two cross-sectional studies, we compared data concerning sexual behavior collected with paper forms to data collected with PDA-based forms in Ancon (Lima. Results The first study enrolled 200 participants (18–29 years. General agreement between data collected with paper format and handheld computers was 86%. Categorical variables agreement was between 70.5% and 98.5% (Kappa: 0.43–0.86 while numeric variables agreement was between 57.1% and 79.8% (Spearman: 0.76–0.95. Agreement and correlation were higher in those who had completed at least high school than those with less education. The second study enrolled 198 participants. Rates of responses to sensitive questions were similar between both kinds of questionnaires. However, the number of inconsistencies (p = 0.0001 and missing values (p = 0.001 were significantly higher in paper questionnaires. Conclusion This study showed the value of the use of handheld computers for collecting sensitive data, since a high level of agreement between paper and PDA responses was reached. In addition, a lower number of inconsistencies and missing values were found with the PDA-based system. This study has demonstrated that it is feasible to develop a low-cost application for handheld computers, and that PDAs are feasible alternatives for collecting field data in a developing country.

  13. Monitoring of WEEE plastics in regards to brominated flame retardants using handheld XRF

    Energy Technology Data Exchange (ETDEWEB)

    Aldrian, Alexia, E-mail: alexia.aldrian@unileoben.ac.at [Chair of Waste Processing Technology and Waste Management, Montanuniversitaet Leoben, Franz-Josef-Straße 18, 8700 Leoben (Austria); Ledersteger, Alfred, E-mail: a.ledersteger@saubermacher.at [Saubermacher Dienstleistungs AG, Hans-Roth-Straße 1, 8073 Feldkirchen bei Graz (Austria); Pomberger, Roland, E-mail: roland.pomberger@unileoben.ac.at [Chair of Waste Processing Technology and Waste Management, Montanuniversitaet Leoben, Franz-Josef-Straße 18, 8700 Leoben (Austria)

    2015-02-15

    Highlights: • Specification of an empirical factor for conversion from bromine to PBB and PBDE. • The handheld XRF device was validated for this particular application. • A very large number of over 4600 pieces of monitor housings was analysed. • The recyclable fraction mounts up to 85% for TV but only 53% of PC waste plastics. • A high percentage of pieces with bromine contents of over 50,000 ppm was obtained. - Abstract: This contribution is focused on the on-site determination of the bromine content in waste electrical and electronic equipment (WEEE), in particular waste plastics from television sets (TV) and personal computer monitors (PC) using a handheld X-ray fluorescence (XRF) device. The described approach allows the examination of samples in regards to the compliance with legal specifications for polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs) directly after disassembling and facilitates the sorting out of plastics with high contents of brominated flame retardants (BFRs). In all, over 3000 pieces of black (TV) and 1600 pieces of grey (PC) plastic waste were analysed with handheld XRF technique for this study. Especially noticeable was the high percentage of pieces with a bromine content of over 50,000 ppm for TV (7%) and PC (39%) waste plastics. The applied method was validated by comparing the data of handheld XRF with results obtained by GC–MS. The results showed the expected and sufficiently accurate correlation between these two methods. It is shown that handheld XRF technique is an effective tool for fast monitoring of large volumes of WEEE plastics in regards to BFRs for on-site measurements.

  14. Human Handheld-Device Interaction : An Adaptive User Interface

    NARCIS (Netherlands)

    Fitrianie, S.

    2010-01-01

    The move to smaller, lighter and more powerful (mobile) handheld devices, whe-ther PDAs or smart-phones, looks like a trend that is building up speed. With numerous embedded technologies and wireless connectivity, the drift opens up unlimited opportunities in daily activities that are both more

  15. The availability of relatively cheap hand-held Global Positioning ...

    African Journals Online (AJOL)

    spamer

    conditions, so the approach failed to produce results ... Hand-held Global Positioning System (GPS) receivers provide opportunities for detailed and rapid mapping of features ..... TICKELL, W. L. N. 1968 — The biology of the great albatrosses,.

  16. Hand-held electronic data collection and procedure environment

    International Nuclear Information System (INIS)

    Kennedy, E.; Doniz, K.

    1996-01-01

    As part of a CANDU Owners Group project, AECL has developed a hand-held electronic data collection and procedure environment. Integral to this environment is the C omputerized Procedure Engine . The development of the CPE allows operators, maintainers, and technical support staff to execute virtually any type of station procedure on a general-purpose PC-compatible hand-held computer. There are several advantages to using the computerized procedures: less paper use and handling, reduction in human error, reduction in rework in the field, an increase in procedural compliance, and immediate availability of data to download to databases and plant information systems. The paper describes: the advantages of using computerized procedures, why early forms of computerized procedures were inadequate, the features that the C omputerized Procedure Engine o ffers to the user, the streamlined life cycle of a computerized procedure, and field experience. The paper concludes that computerized procedures are ready for pilot applications at stations. (author)

  17. Measuring thyroid uptake with hand-held radiation monitors

    International Nuclear Information System (INIS)

    Deschamps, M.

    1987-04-01

    With the use of Iodine 123, 125 and 131 and some compounds of Technetium-99 m, a fraction of the isotopes can be trapped in the thyroid of the technicians. We used the hand-held radiation contamination or survey meters of the nine (9) Nuclear medicine departments we visited to see if they were adequate for the evaluation of thyroid uptake of the users. Measurements on a neck-phanton helped us to determine a minimum detectable activity for each isotope. We were then able to check if the measurements of investigations and action levels were possible. None of the hand-held radiation monitors are completely satisfactory for the measure of thyroid uptake of the user. We discuss a class of equipment capable of measuring radiation emissions at the investigation level. Measurement at the action level is possible with meters having scintillation or proportional probes but none of them permits the discrimination in energy required for a quantitative evaluation of the radioisotopes used

  18. Handheld Universal Diagnostic Sensor

    Science.gov (United States)

    Chan, Eugene

    2012-01-01

    The rHEALTH technology is designed to shrink an entire hospital testing laboratory onto a handheld device. A physician or healthcare provider performs the test by collecting a fingerstick of blood from a patient. The tiny volume of blood is inserted into the rHEALTH device. Inside the device is a microfluidic chip that contains small channels about the width of a human hair. These channels help move the blood and analyze the blood sample. The rHEALTH sensor uses proprietary reagents called nanostrips, which are nanoscale test strips that enable the clinical assays. The readout is performed by laser-induced fluorescence. Overall, the time from blood collection through analysis is less than a minute.

  19. Exploring streamwater mixing dynamics via handheld thermal infrared imagery

    NARCIS (Netherlands)

    Antonelli, Marta; Klaus, Julian; Smettem, Keith; Teuling, Ryan; Pfister, Laurent

    2017-01-01

    Stream confluences are important hotspots of aquatic ecological processes. Water mixing dynamics at stream confluences influence physio-chemical characteristics of the stream as well as sediment mobilisation and pollutant dispersal. In this study, we investigated the potential for handheld

  20. Some emergency instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Burgess, P H

    1986-10-01

    The widespread release of activity and the resultant spread of contamination after the Chernobyl accident resulted in requests to NRPB to provide instruments for, and expertise in, the measurement of radiation. The most common request was for advice on the usefulness of existing instruments, but Board staff were also involved in their adaptation or in the development of new instruments specially to meet the circumstances of the accident. The accident occurred on 26 April. On 1 May, NRPB was involved at Heathrow Airport in the monitoring of the British students who had returned from Kiev and Minsk. The main purpose was to reassure the students by checking that their persons and belongings did not have significant surface contamination. Additional measurements were also made of iodine activity in thyroid using hand-held detectors or a mobile body monitor. This operation was arranged with the Foreign and Commonwealth Office, which had also received numerous requests for instruments from embassies and consulates in countries close to the scene of the accident. There was concern for the well-being of staff and other United Kingdom nationals who resided in or intended to visit the most affected countries. The board supplied suitable instruments, and the FCO distributed them to embassies. The frequency of environmental monitoring was increased from 29 April in anticipation of contamination and appropriate Board instrumentation was deployed. After the Chernobyl cloud arrived in the UK on 2 May, there were numerous requests from local government, public authorities, private companies and members of the public for information and advice on monitoring equipment and procedures. Some of these requirements could be met with existing equipment but members of the public were usually advised not to proceed. At a later stage, the contamination of foodstuffs and livestock required the development of an instrument capable of detecting low levels of {sup 137}Cs and {sup 134}Cs in food

  1. Monitoring invasive plants using hand-held GIS technology

    Science.gov (United States)

    Theresa M. Mau-Crimmins; Barron J. Orr

    2005-01-01

    Successful control of invasive species requires a clear picture of the spatial extent of infestations. The latest mapping technology involves coupling global position systems and handheld computers running geographic information systems software in the field. A series of workshops applying this technology to mapping weeds was developed and presented to Weed Management...

  2. Accuracy of Handheld Blood Glucose Meters at High Altitude

    NARCIS (Netherlands)

    de Mol, Pieter; Krabbe, Hans G.; de Vries, Suzanna T.; Fokkert, Marion J.; Dikkeschei, Bert D.; Rienks, Rienk; Bilo, Karin M.; Bilo, Henk J. G.

    2010-01-01

    Background: Due to increasing numbers of people with diabetes taking part in extreme sports (e. g., high-altitude trekking), reliable handheld blood glucose meters (BGMs) are necessary. Accurate blood glucose measurement under extreme conditions is paramount for safe recreation at altitude. Prior

  3. A hand-held robotic device for peripheral intravenous catheterization.

    Science.gov (United States)

    Cheng, Zhuoqi; Davies, Brian L; Caldwell, Darwin G; Barresi, Giacinto; Xu, Qinqi; Mattos, Leonardo S

    2017-12-01

    Intravenous catheterization is frequently required for numerous medical treatments. However, this process is characterized by a high failure rate, especially when performed on difficult patients such as newborns and infants. Very young patients have small veins, and that increases the chances of accidentally puncturing the catheterization needle directly through them. In this article, we present the design, development and experimental evaluation of a novel hand-held robotic device for improving the process of peripheral intravenous catheterization by facilitating the needle insertion procedure. To our knowledge, this design is the first hand-held robotic device for assisting in the catheterization insertion task. Compared to the other available technologies, it has several unique advantages such as being compact, low-cost and able to reliably detect venipuncture. The system is equipped with an electrical impedance sensor at the tip of the catheterization needle, which provides real-time measurements used to supervise and control the catheter insertion process. This allows the robotic system to precisely position the needle within the lumen of the target vein, leading to enhanced catheterization success rate. Experiments conducted to evaluate the device demonstrated that it is also effective to deskill the task. Naïve subjects achieved an average catheterization success rate of 88% on a 1.5 mm phantom vessel with the robotic device versus 12% with the traditional unassisted system. The results of this work prove the feasibility of a hand-held assistive robotic device for intravenous catheterization and show that such device has the potential to greatly improve the success rate of these difficult operations.

  4. Compact instrument for fluorescence image-guided surgery

    Science.gov (United States)

    Wang, Xinghua; Bhaumik, Srabani; Li, Qing; Staudinger, V. Paul; Yazdanfar, Siavash

    2010-03-01

    Fluorescence image-guided surgery (FIGS) is an emerging technique in oncology, neurology, and cardiology. To adapt intraoperative imaging for various surgical applications, increasingly flexible and compact FIGS instruments are necessary. We present a compact, portable FIGS system and demonstrate its use in cardiovascular mapping in a preclinical model of myocardial ischemia. Our system uses fiber optic delivery of laser diode excitation, custom optics with high collection efficiency, and compact consumer-grade cameras as a low-cost and compact alternative to open surgical FIGS systems. Dramatic size and weight reduction increases flexibility and access, and allows for handheld use or unobtrusive positioning over the surgical field.

  5. Neurosurgery contact handheld probe based on sapphire shaped crystal

    Science.gov (United States)

    Shikunova, I. A.; Stryukov, D. O.; Rossolenko, S. N.; Kiselev, A. M.; Kurlov, V. N.

    2017-01-01

    A handheld contact probe based on sapphire shaped crystal is developed for intraoperative spectrally-resolved optical diagnostics, laser coagulation and aspiration of malignant brain tissue. The technology was integrated into the neurosurgical workflow for intraoperative real-time identification and removing of invasive brain cancer.

  6. A handheld support system to facilitate stereological measurements and mapping of branching structures

    DEFF Research Database (Denmark)

    Gardi, J.E.; Wulfsohn, Dvora-Laiô; Nyengaard, J.R.

    2007-01-01

    specifications, software and Graphical User Interface (GUI) development, functionality and application of the handheld system using four examples: (1) sampling monkey lung bronchioles for estimation of diameter and wall thickness (2) sampling rat kidney for estimating number of arteries and arterioles......‘BranchSampler' is a system for computer-assisted manual stereology written for handheld devices running Windows CE. The system has been designed specifically to streamline data collection and optimize sampling of tree-like branching structures, with particular aims of reducing user errors, saving...

  7. Imaging Emission Spectra with Handheld and Cellphone Cameras

    Science.gov (United States)

    Sitar, David

    2012-01-01

    As point-and-shoot digital camera technology advances it is becoming easier to image spectra in a laboratory setting on a shoestring budget and get immediate results. With this in mind, I wanted to test three cameras to see how their results would differ. Two undergraduate physics students and I used one handheld 7.1 megapixel (MP) digital Cannon…

  8. Development of a Low Cost Microcontroller-Enabled Handheld Sunphotometer and Comparison with NASA AERONET and MODIS

    Science.gov (United States)

    Krintz, I. A.; Ruble, W.; Sherman, J. P.

    2017-12-01

    Satellite-based measurements of aerosol optical depth (AOD), such as those made by NASA's Moderate Resolution Imaging Spectroradiometer (MODIS) aboard the TERRA and AQUA spacecraft, are often used in studies of aerosol direct radiative forcing (DRF) on regional to global scales due to daily near-global coverage. However, these measurements require validation by ground-based instrumentation, which is limited due to the cost of research-grade instrumentation. Furthermore, satellite-based AOD agreement with "ground-truth" instruments is weaker over mountainous regions (Levy et al., 2010). To aid in satellite validation, a low cost handheld sunphotometer has been developed which will be suitable for deployment to multiple sites to form a citizen science network as part of an upcoming proposal. A microcontroller, along with temperature and pressure sensors, has been included in this design to ease the process of taking measurements and transferring data for processing. Although LED-based sunphotometers have been used for a number of years (Brooks and Mims, 2001), this design uses filtered photodiodes which appear to have less of a temperature dependence. The interface has been designed to be intuitive to citizen scientists of all ages, nationalities, and backgrounds, so that deployment to primary schools and international sites will be as seamless as possible. Presented here is the instrument design, as well as initial results of a comparison with NASA Aerosol Robotic Network (AERONET) and MODIS-measured AOD. Future revisions to the instrument design, such as incorporation of surface-mount devices to cut down on circuit board size, will allow for an even smaller and more cost effective solution suitable for a global sunphotometer network.

  9. Diagnostic efficacy of handheld devices for emergency radiologic consultation.

    LENUS (Irish Health Repository)

    Toomey, Rachel J

    2010-02-01

    Orthopedic injury and intracranial hemorrhage are commonly encountered in emergency radiology, and accurate and timely diagnosis is important. The purpose of this study was to determine whether the diagnostic accuracy of handheld computing devices is comparable to that of monitors that might be used in emergency teleconsultation.

  10. Octopus: embracing the energy efficiency of handheld multimedia computers

    NARCIS (Netherlands)

    Havinga, Paul J.M.; Smit, Gerardus Johannes Maria

    1999-01-01

    In the MOBY DICK project we develop and define the architecture of a new generation of mobile hand-held computers called Mobile Digital Companions. The Companions must meet several major requirements: high performance, energy efficient, a notion of Quality of Service (QoS), small size, and low

  11. Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children

    Directory of Open Access Journals (Sweden)

    Janson C

    2006-04-01

    Full Text Available Abstract Background Exhaled nitric oxide (NO measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO was compared with a standard stationary chemiluminescence unit (NIOX. Methods A total of 71 subjects (6–60 years; 36 males, both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots, measurement feasibility (success rate with 6 attempts and repeatability (intrasubject SD. Results Success rate was high (≥ 84% in both devices for both adults and children. The subjects represented a FENO range of 8–147 parts per billion (ppb. When comparing the mean of three measurements (n = 61, the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. Conclusion The hand-held device (NIOX MINO and the stationary system (NIOX are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO is used. The hand-held device shows good repeatability, and it

  12. Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children.

    Science.gov (United States)

    Alving, K; Janson, C; Nordvall, L

    2006-04-20

    Exhaled nitric oxide (NO) measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO) was compared with a standard stationary chemiluminescence unit (NIOX). A total of 71 subjects (6-60 years; 36 males), both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s) in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots), measurement feasibility (success rate with 6 attempts) and repeatability (intrasubject SD). Success rate was high (> or = 84%) in both devices for both adults and children. The subjects represented a FENO range of 8-147 parts per billion (ppb). When comparing the mean of three measurements (n = 61), the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. The hand-held device (NIOX MINO) and the stationary system (NIOX) are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO) is used. The hand-held device shows good repeatability, and it can be used successfully on adults and most children

  13. Neurosurgical hand-held optical coherence tomography (OCT) forward-viewing probe

    Science.gov (United States)

    Sun, Cuiru; Lee, Kenneth K. C.; Vuong, Barry; Cusimano, Michael; Brukson, Alexander; Mariampillai, Adrian; Standish, Beau A.; Yang, Victor X. D.

    2012-02-01

    A prototype neurosurgical hand-held optical coherence tomography (OCT) imaging probe has been developed to provide micron resolution cross-sectional images of subsurface tissue during open surgery. This new ergonomic hand-held probe has been designed based on our group's previous work on electrostatically driven optical fibers. It has been packaged into a catheter probe in the familiar form factor of the clinically accepted Bayonet shaped neurosurgical non-imaging Doppler ultrasound probes. The optical design was optimized using ZEMAX simulation. Optical properties of the probe were tested to yield an ~20 um spot size, 5 mm working distance and a 3.5 mm field of view. The scan frequency can be increased or decreased by changing the applied voltage. Typically a scan frequency of less than 60Hz is chosen to keep the applied voltage to less than 2000V. The axial resolution of the probe was ~15 um (in air) as determined by the OCT system. A custom-triggering methodology has been developed to provide continuous stable imaging, which is crucial for clinical utility. Feasibility of this probe, in combination with a 1310 nm swept source OCT system was tested and images are presented to highlight the usefulness of such a forward viewing handheld OCT imaging probe. Knowledge gained from this research will lay the foundation for developing new OCT technologies for endovascular management of cerebral aneurysms and transsphenoidal neuroendoscopic treatment of pituitary tumors.

  14. Interactive topology optimization on hand-held devices

    DEFF Research Database (Denmark)

    Aage, Niels; Nobel-Jørgensen, Morten; Andreasen, Casper Schousboe

    2013-01-01

    This paper presents an interactive topology optimization application designed for hand-held devices running iOS or Android. The TopOpt app solves the 2D minimum compliance problem with interactive control of load and support positions as well as volume fraction. Thus, it is possible to change......OS devices from the Apple App Store, at Google Play for the Android platform, and a web-version can be run from www.topopt.dtu.dk....

  15. Technology-enabled division of labour: the use of handhelds

    NARCIS (Netherlands)

    Benders, J.G.J.M.; Schouteten, R.L.J.; Ruijsscher, C. de

    2012-01-01

    Using the task pool model and data from 15 establishments in the Dutch hospitality industry, this study shows how and why applying handhelds affects the division of labour. These devices allow to split the waiters' jobs into separate tasks which tend to be combined into two separate "sub jobs": the

  16. Technology-enabled division of labour : The use of handhelds

    NARCIS (Netherlands)

    Benders, J.G.J.M.; Schouteten, R.; de Ruijsscher, C.

    2012-01-01

    Using the task pool model and data from 15 establishments in the Dutch hospitality industry, this study shows how and why applying handhelds affects the division of labour. These devices allow to split the waiters' jobs into separate tasks which tend to be combined into two separate "sub jobs": the

  17. Abdominoplasty and seroma: a prospective randomised study comparing scalpel and handheld electrocautery dissection.

    Science.gov (United States)

    Marsh, Dan J; Fox, Andreas; Grobbelaar, Adriaan O; Chana, Jagdeep S

    2015-02-01

    Seroma formation remains a significant problem in abdominoplasty procedures--the cause of which remains to be elucidated. It has been suggested that one of the causative factors for seroma formation is the use of handheld electrocautery as opposed to scalpel for abdominal flap dissection. Prospective trial in 102 consecutive abdominoplasty patients randomised to have abdominal flap dissection with either handheld electrocautery device on 'coagulation setting' or sharp dissection with scalpel and monopolar electrocautery forceps for haemostasis. In all other aspects the surgical technique was identical between the two groups. All drains were removed at 48 h, irrespective of drain volume. Primary outcome measure is postoperative seroma formation on clinical examination, secondary outcome measures are drain volume, weight of tissue removed, effect of liposuction and patient BMI. Both study groups were similar in demographics with no significant difference in weight of tissue excised, BMI, drain output or post operative complictions. There was no significant difference in seroma formation rates between the handheld electrocautery group (17.2%) and the sharp dissection group (20.1%). Overall, the seroma rate was 18.6%. Liposuction to the flanks at the time of abdominoplasty was found to significantly increase the incidence of seroma, compared to patients having abdominoplasty alone. Use of handheld electrocautery rather than scalpel for tissue dissection does not lead to increased seroma formation in abdominoplasty patients. Concomitant liposuction at the time of abdominoplasty increases the risk of seroma formation compared to patients having abdominoplasty alone. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Video Browsing on Handheld Devices

    Science.gov (United States)

    Hürst, Wolfgang

    Recent improvements in processing power, storage space, and video codec development enable users now to playback video on their handheld devices in a reasonable quality. However, given the form factor restrictions of such a mobile device, screen size still remains a natural limit and - as the term "handheld" implies - always will be a critical resource. This is not only true for video but any data that is processed on such devices. For this reason, developers have come up with new and innovative ways to deal with large documents in such limited scenarios. For example, if you look at the iPhone, innovative techniques such as flicking have been introduced to skim large lists of text (e.g. hundreds of entries in your music collection). Automatically adapting the zoom level to, for example, the width of table cells when double tapping on the screen enables reasonable browsing of web pages that have originally been designed for large, desktop PC sized screens. A multi touch interface allows you to easily zoom in and out of large text documents and images using two fingers. In the next section, we will illustrate that advanced techniques to browse large video files have been developed in the past years, as well. However, if you look at state-of-the-art video players on mobile devices, normally just simple, VCR like controls are supported (at least at the time of this writing) that only allow users to just start, stop, and pause video playback. If supported at all, browsing and navigation functionality is often restricted to simple skipping of chapters via two single buttons for backward and forward navigation and a small and thus not very sensitive timeline slider.

  19. Web-Based Spatial Training Using Handheld Touch Screen Devices

    Science.gov (United States)

    Martin-Dorta, Norena; Saorin, Jose Luis; Contero, Manuel

    2011-01-01

    This paper attempts to harness the opportunities for mobility and the new user interfaces that handheld touch screen devices offer, in a non-formal learning context, with a view to developing spatial ability. This research has addressed two objectives: first, analyzing the effects that training can have on spatial visualisation using the…

  20. Multimodal ophthalmic imaging using handheld spectrally encoded coherence tomography and reflectometry (SECTR)

    Science.gov (United States)

    Leeburg, Kelsey C.; El-Haddad, Mohamed T.; Malone, Joseph D.; Terrones, Benjamin D.; Tao, Yuankai K.

    2018-02-01

    Scanning laser ophthalmoscopy (SLO) provides high-speed, noninvasive en face imaging of the retinal fundus. Optical coherence tomography (OCT) is the current "gold-standard" for ophthalmic diagnostic imaging and enables depth-resolved visualization of ophthalmic structures and image-based surrogate biomarkers of disease. We present a compact optical and mechanical design for handheld spectrally encoded coherence tomography and reflectometry (SECTR) for multimodality en face spectrally encoded reflectometry (SER) and cross-sectional OCT imaging. We custom-designed a double-pass telecentric scan lens, which halves the size of 4-f optical relays and allowed us to reduce the footprint of our SECTR scan-head by a factor of >2.7x (volume) over our previous design. The double-pass scan lens was optimized for diffraction-limited performance over a +/-10° scan field. SECTR optics and optomechanics were combined in a compact rapid-prototyped enclosure with dimensions 87 x 141.8 x 137 mm (w x h x d). SECTR was implemented using a custom-built 400 kHz 1050 nm swept-source. OCT and SER were simultaneously digitized on dual input channels of a 4 GS/s digitizer at 1.4 GS/s per channel. In vivo human en face SER and cross-sectional OCT images were acquired at 350 fps. OCT volumes of 1000 B-scans were acquired in 2.86 s. We believe clinical translation of our compact handheld design will benefit point-of-care ophthalmic diagnostics in patients who are unable to be imaged on conventional slit-lamp based systems, such as infants and the bedridden. When combined with multi-volumetric registration methods, handheld SECTR will have advantages in motion-artifact free imaging over existing handheld technologies.

  1. Calibration curves for commercial copper and aluminum alloys using handheld laser-induced breakdown spectroscopy

    Science.gov (United States)

    Bennett, B. N.; Martin, M. Z.; Leonard, D. N.; Garlea, E.

    2018-03-01

    Handheld laser-induced breakdown spectroscopy (HH LIBS) was used to study the elemental composition of four copper alloys and four aluminum alloys to produce calibration curves. The HH LIBS instrument used is a SciAps Z-500, commercially available, that contains a class-1 solid-state laser with an output wavelength of 1532 nm, laser energy of 5 mJ/pulse, and a pulse duration of 5 ns. Test samples were solid specimens comprising copper and aluminum alloys and data were collected from the samples' surface at three different locations, employing a 12-point-grid pattern for each data set. All three data sets of the spectra were averaged, and the intensity, corrected by subtraction of background, was used to produce the elemental calibration curves. Calibration curves are presented for the matrix elements, copper and aluminum, as well as several minor elements. The surface damage produced by the laser was examined by microscopy. The alloys were tested in air and in a glovebox to evaluate the instrument's ability to identify the constituents within materials under different environmental conditions. The main objective of using this HH LIBS technology is to determine its capability to fingerprint the presence of certain elements related to subpercent level within materials in real time and in situ, as a starting point for undertaking future complex material characterization work.

  2. Jump Training in Youth Soccer Players: Effects of Haltere Type Handheld Loading.

    Science.gov (United States)

    Rosas, F; Ramirez-Campillo, R; Diaz, D; Abad-Colil, F; Martinez-Salazar, C; Caniuqueo, A; Cañas-Jamet, R; Loturco, I; Nakamura, F Y; McKenzie, C; Gonzalez-Rivera, J; Sanchez-Sanchez, J; Izquierdo, M

    2016-12-01

    The aim of this study was to compare the effects of a jump training program, with or without haltere type handheld loading, on maximal intensity exercise performance. Youth soccer players (12.1±2.2 y) were assigned to either a jump training group (JG, n=21), a jump training group plus haltere type handheld loading (LJG, n=21), or a control group following only soccer training (CG, n=21). Athletes were evaluated for maximal-intensity performance measures before and after 6 weeks of training, during an in-season training period. The CG achieved a significant change in maximal kicking velocity only (ES=0.11-0.20). Both jump training groups improved in right leg (ES=0.28-0.45) and left leg horizontal countermovement jump with arms (ES=0.32-0.47), horizontal countermovement jump with arms (ES=0.28-0.37), vertical countermovement jump with arms (ES=0.26), 20-cm drop jump reactive strength index (ES=0.20-0.37), and maximal kicking velocity (ES=0.27-0.34). Nevertheless, compared to the CG, only the LJG exhibited greater improvements in all performance tests. Therefore, haltere type handheld loading further enhances performance adaptations during jump training in youth soccer players. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Application of Handheld Tele-ECG for Health Care Delivery in Rural India

    Directory of Open Access Journals (Sweden)

    Meenu Singh

    2014-01-01

    Full Text Available Telemonitoring is a medical practice that involves remotely monitoring patients who are not at the same location as the health care provider. The purpose of our study was to use handheld tele-electrocardiogram (ECG developed by Bhabha Atomic Research Center (BARC to identify heart conditions in the rural underserved population where the doctor-patient ratio is low and access to health care is difficult. The objective of our study was clinical validation of handheld tele-ECG as a screening tool for evaluation of cardiac diseases in the rural population. ECG was obtained in 450 individuals (mean age 31.49 ± 20.058 residing in the periphery of Chandigarh, India, from April 2011 to March 2013, using the handheld tele-ECG machine. The data were then transmitted to physicians in Postgraduate Institute of Medical Education and Research (PGIMER, Chandigarh, for their expert opinion. ECG was interpreted as normal in 70% individuals. Left ventricular hypertrophy (9.3% was the commonest abnormality followed closely by old myocardial infarction (5.3%. Patient satisfaction was reported to be ~95%. Thus, it can be safely concluded that tele-ECG is a portable, cost-effective, and convenient tool for diagnosis and monitoring of heart diseases and thus improves quality and accessibility, especially in rural areas.

  4. Towards Vision-Based Control of a Handheld Micromanipulator for Retinal Cannulation in an Eyeball Phantom

    Science.gov (United States)

    Becker, Brian C.; Yang, Sungwook; MacLachlan, Robert A.; Riviere, Cameron N.

    2012-01-01

    Injecting clot-busting drugs such as t-PA into tiny vessels thinner than a human hair in the eye is a challenging procedure, especially since the vessels lie directly on top of the delicate and easily damaged retina. Various robotic aids have been proposed with the goal of increasing safety by removing tremor and increasing precision with motion scaling. We have developed a fully handheld micromanipulator, Micron, that has demonstrated reduced tremor when cannulating porcine retinal veins in an “open sky” scenario. In this paper, we present work towards handheld robotic cannulation with the goal of vision-based virtual fixtures guiding the tip of the cannula to the vessel. Using a realistic eyeball phantom, we address sclerotomy constraints, eye movement, and non-planar retina. Preliminary results indicate a handheld micromanipulator aided by visual control is a promising solution to retinal vessel occlusion. PMID:24649479

  5. MEMS-based handheld fourier domain Doppler optical coherence tomography for intraoperative microvascular anastomosis imaging.

    Directory of Open Access Journals (Sweden)

    Yong Huang

    Full Text Available To demonstrate the feasibility of a miniature handheld optical coherence tomography (OCT imager for real time intraoperative vascular patency evaluation in the setting of super-microsurgical vessel anastomosis.A novel handheld imager Fourier domain Doppler optical coherence tomography based on a 1.3-µm central wavelength swept source for extravascular imaging was developed. The imager was minimized through the adoption of a 2.4-mm diameter microelectromechanical systems (MEMS scanning mirror, additionally a 12.7-mm diameter lens system was designed and combined with the MEMS mirror to achieve a small form factor that optimize functionality as a handheld extravascular OCT imager. To evaluate in-vivo applicability, super-microsurgical vessel anastomosis was performed in a mouse femoral vessel cut and repair model employing conventional interrupted suture technique as well as a novel non-suture cuff technique. Vascular anastomosis patency after clinically successful repair was evaluated using the novel handheld OCT imager.With an adjustable lateral image field of view up to 1.5 mm by 1.5 mm, high-resolution simultaneous structural and flow imaging of the blood vessels were successfully acquired for BALB/C mouse after orthotopic hind limb transplantation using a non-suture cuff technique and BALB/C mouse after femoral artery anastomosis using a suture technique. We experimentally quantify the axial and lateral resolution of the OCT to be 12.6 µm in air and 17.5 µm respectively. The OCT has a sensitivity of 84 dB and sensitivity roll-off of 5.7 dB/mm over an imaging range of 5 mm. Imaging with a frame rate of 36 Hz for an image size of 1000(lateral×512(axial pixels using a 50,000 A-lines per second swept source was achieved. Quantitative vessel lumen patency, lumen narrowing and thrombosis analysis were performed based on acquired structure and Doppler images.A miniature handheld OCT imager that can be used for intraoperative evaluation of

  6. Ultra-compact swept-source optical coherence tomography handheld probe with motorized focus adjustment (Conference Presentation)

    Science.gov (United States)

    LaRocca, Francesco; Nankivil, Derek; Keller, Brenton; Farsiu, Sina; Izatt, Joseph A.

    2017-02-01

    Handheld optical coherence tomography (OCT) systems facilitate imaging of young children, bedridden subjects, and those with less stable fixation. Smaller and lighter OCT probes allow for more efficient imaging and reduced operator fatigue, which is critical for prolonged use in either the operating room or neonatal intensive care unit. In addition to size and weight, the imaging speed, image quality, field of view, resolution, and focus correction capability are critical parameters that determine the clinical utility of a handheld probe. Here, we describe an ultra-compact swept source (SS) OCT handheld probe weighing only 211 g (half the weight of the next lightest handheld SSOCT probe in the literature) with 20.1 µm lateral resolution, 7 µm axial resolution, 102 dB peak sensitivity, a 27° x 23° field of view, and motorized focus adjustment for refraction correction between -10 to +16 D. A 2D microelectromechanical systems (MEMS) scanner, a converging beam-at-scanner telescope configuration, and an optical design employing 6 different custom optics were used to minimize device size and weight while achieving diffraction limited performance throughout the system's field of view. Custom graphics processing unit (GPU)-accelerated software was used to provide real-time display of OCT B-scans and volumes. Retinal images were acquired from adult volunteers to demonstrate imaging performance.

  7. Quality-Based Backlight Optimization for Video Playback on Handheld Devices

    Directory of Open Access Journals (Sweden)

    Liang Cheng

    2007-01-01

    Full Text Available For a typical handheld device, the backlight accounts for a significant percentage of the total energy consumption (e.g., around 30% for a Compaq iPAQ 3650. Substantial energy savings can be achieved by dynamically adapting backlight intensity levels on such low-power portable devices. In this paper, we analyze the characteristics of video streaming services and propose a cross-layer optimization scheme called quality adapted backlight scaling (QABS to achieve backlight energy savings for video playback applications on handheld devices. Specifically, we present a fast algorithm to optimize backlight dimming while keeping the degradation in image quality to a minimum so that the overall service quality is close to a specified threshold. Additionally, we propose two effective techniques to prevent frequent backlight switching, which negatively affects user perception of video. Our initial experimental results indicate that the energy used for backlight is significantly reduced, while the desired quality is satisfied. The proposed algorithms can be realized in real time.

  8. A conceptual application for computer-based procedures for handheld devices

    Energy Technology Data Exchange (ETDEWEB)

    Sofie, Lunde-Hanssen Linda [Industrial Psychology, Institute for Energy Technology, Halden (Norway)

    2014-08-15

    This paper describes the concepts and proposed design principles for an application for computer-based procedures (CBPs) for field operators in the nuclear domain (so-called handheld procedures). The concept is focused on the field operators' work with procedures and the communication and coordination between field operators and control room operators. The goal is to overcome challenges with shared situation awareness (SA) in a distributed team by providing effective and usable information design. An iterative design method and user-centred design is used for tailoring the concept to the context of field operations. The resulting concept supports the execution of procedures where close collaboration is needed between control room and field operations, e.g. where particular procedure steps are executed from remote control points and others from the control room. The resulting conceptual application for CBPs on handheld devices is developed for mitigating the SA challenges and designing for usability and ease of use.

  9. A conceptual application for computer-based procedures for handheld devices

    International Nuclear Information System (INIS)

    Sofie, Lunde-Hanssen Linda

    2014-01-01

    This paper describes the concepts and proposed design principles for an application for computer-based procedures (CBPs) for field operators in the nuclear domain (so-called handheld procedures). The concept is focused on the field operators' work with procedures and the communication and coordination between field operators and control room operators. The goal is to overcome challenges with shared situation awareness (SA) in a distributed team by providing effective and usable information design. An iterative design method and user-centred design is used for tailoring the concept to the context of field operations. The resulting concept supports the execution of procedures where close collaboration is needed between control room and field operations, e.g. where particular procedure steps are executed from remote control points and others from the control room. The resulting conceptual application for CBPs on handheld devices is developed for mitigating the SA challenges and designing for usability and ease of use

  10. China Naval Modernization: Implications for U.S. Navy Capabilities?Background and Issues for Congress

    Science.gov (United States)

    2010-07-23

    its security and interests. Foreign Ministry spokesman Qin Gang made the remarks in response to a question on a scheduled joint naval drill between...2005: 27; “China Sub Tracked By U.S. Off Guam Before Japan Intrusion,” Japan Times, November 17, 2004. 59 Bill Gertz, “China Sub Secretly Stalked ...2006; Bill Gertz, “Defenses On [sic] Subs To Be Reviewed,” Washington Times, November 14, 2006; En-Lai Yeoh, “Fallon Confirms Chinese Stalked Carrier

  11. China Naval Modernization: Implications for U.S. Navy Capabilities - Background and Issues for Congress

    Science.gov (United States)

    2010-08-05

    waters that were engaged in activities that would impact on its security and interests. Foreign Ministry spokesman Qin Gang made the remarks in response...November 17, 2004. 63 Bill Gertz, “China Sub Secretly Stalked U.S. Fleet,” Washington Times, November 13, 2006: 13; Philip Creed, “Navy Confirms Chinese...2006; En-Lai Yeoh, “Fallon Confirms Chinese Stalked Carrier,” NavyTimes.com, November 14, 2006; Bill Gertz, “Admiral Says Sub Risked A Shootout

  12. Handheld Nonlinear Detection of Delamination and Intrusion Faults in Composites, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In Phase I of the SBIR program, LEEOAT Company will develop a hand-held high-resolution ultrasonic nonlinear imager for non-destructive inspection (NDI) of...

  13. Combining heterogenous features for 3D hand-held object recognition

    Science.gov (United States)

    Lv, Xiong; Wang, Shuang; Li, Xiangyang; Jiang, Shuqiang

    2014-10-01

    Object recognition has wide applications in the area of human-machine interaction and multimedia retrieval. However, due to the problem of visual polysemous and concept polymorphism, it is still a great challenge to obtain reliable recognition result for the 2D images. Recently, with the emergence and easy availability of RGB-D equipment such as Kinect, this challenge could be relieved because the depth channel could bring more information. A very special and important case of object recognition is hand-held object recognition, as hand is a straight and natural way for both human-human interaction and human-machine interaction. In this paper, we study the problem of 3D object recognition by combining heterogenous features with different modalities and extraction techniques. For hand-craft feature, although it reserves the low-level information such as shape and color, it has shown weakness in representing hiconvolutionalgh-level semantic information compared with the automatic learned feature, especially deep feature. Deep feature has shown its great advantages in large scale dataset recognition but is not always robust to rotation or scale variance compared with hand-craft feature. In this paper, we propose a method to combine hand-craft point cloud features and deep learned features in RGB and depth channle. First, hand-held object segmentation is implemented by using depth cues and human skeleton information. Second, we combine the extracted hetegerogenous 3D features in different stages using linear concatenation and multiple kernel learning (MKL). Then a training model is used to recognize 3D handheld objects. Experimental results validate the effectiveness and gerneralization ability of the proposed method.

  14. 78 FR 27441 - NIJ Evaluation of Hand-Held Cell Phone Detector Devices

    Science.gov (United States)

    2013-05-10

    ...The National Institute of Justice (NIJ) is soliciting interest in supplying hand-held cell phone detector devices for participation in an evaluation by the NIJ Corrections Technology Center of Excellence (CXCoE).

  15. Optical links in handheld multimedia devices

    Science.gov (United States)

    van Geffen, S.; Duis, J.; Miller, R.

    2008-04-01

    Ever emerging applications in handheld multimedia devices such as mobile phones, laptop computers, portable video games and digital cameras requiring increased screen resolutions are driving higher aggregate bitrates between host processor and display(s) enabling services such as mobile video conferencing, video on demand and TV broadcasting. Larger displays and smaller phones require complex mechanical 3D hinge configurations striving to combine maximum functionality with compact building volumes. Conventional galvanic interconnections such as Micro-Coax and FPC carrying parallel digital data between host processor and display module may produce Electromagnetic Interference (EMI) and bandwidth limitations caused by small cable size and tight cable bends. To reduce the number of signals through a hinge, the mobile phone industry, organized in the MIPI (Mobile Industry Processor Interface) alliance, is currently defining an electrical interface transmitting serialized digital data at speeds >1Gbps. This interface allows for electrical or optical interconnects. Above 1Gbps optical links may offer a cost effective alternative because of their flexibility, increased bandwidth and immunity to EMI. This paper describes the development of optical links for handheld communication devices. A cable assembly based on a special Plastic Optical Fiber (POF) selected for its mechanical durability is terminated with a small form factor molded lens assembly which interfaces between an 850nm VCSEL transmitter and a receiving device on the printed circuit board of the display module. A statistical approach based on a Lean Design For Six Sigma (LDFSS) roadmap for new product development tries to find an optimum link definition which will be robust and low cost meeting the power consumption requirements appropriate for battery operated systems.

  16. Audiovisual Presentations on a Handheld PC are Preferred As an Educational Tool by NICU Parents.

    Science.gov (United States)

    Alur, P; Cirelli, J; Goodstein, M; Bell, T; Liss, J

    2010-01-01

    Health literacy is critical for understanding complex medical problems and necessary for the well being of the patient. Printed educational materials (PM) have limitations in explaining the dynamics of a disease process. Multimedia formats may be useful for enhancing the educational process. To evaluate whether a printed format or animation with commentary on a handheld personal computer (PC) is preferred as an educational tool by parents of a baby in the NICU. PARENTS EVALUATED TWO FORMATS: A 1-page illustrated document from the American Heart Association explaining patent ductus arteriosus (PDA) and animation with commentary on a handheld PC that explained the physiology of PDA in 1 minute. The reading grade level of the PM was 8.6 versus 18.6 for the audio portion of the animated presentation. Parents viewed each format and completed a four-item questionnaire. Parents rated both formats and indicated their preference as printed, animation, or both. Forty-six parents participated in the survey. Parents preferred animation over PM (50% vs. 17.4%. p = 0.02); 39.1% expressed that the animation was excellent; whereas 4.3% expressed that the PM was excellent (p0.05). Parents preferred animation on a small screen handheld PC despite a much higher language level. Because handheld PCs are portable and inexpensive, they can be used effectively at the bedside with low-cost animation to enhance understanding of complex disease conditions.

  17. Epidemiology of Handheld Cell Phone Use While Driving: A Study from a South Indian City

    Directory of Open Access Journals (Sweden)

    Sumanth Mallikarjuna Majgi

    2018-01-01

    Full Text Available Background: Using cell phones while driving contribute to distractions which can potentially cause minor or major road traffic injuries and also stress among other drivers. With this background, the study was done to ascertain the proportion of handheld cell phone use while driving among road users in Mysore city and also patterns of the use by the day of week, type of road, and type of vehicle. Methods: The study was conducted in Mysore, Karnataka, India. Four stretches of roads were observed thrice daily for 1 week. The total number of vehicles passing through the stretch and the number and characteristics of drivers using hand-held cell was noted. Pearson's Chi-square test was used to ascertain the significance of the difference in proportions. Results: The overall proportion of cell phone users was calculated as 1.41/100 vehicles. The observed use of handheld cell phones was 1.78 times higher on nonbusy roads than busy roads (Χ2 = 25.79, P < 0.0001. More than 50% of the handheld phone users were driving a two wheeler, the proportion being 50.5% in busy roads, and 67% in nonbusy roads. There was no difference in the proportion of cell phone use by time of the day or across different days of the week. Conclusions: The proportion of drivers who use cell phones is found to be relatively lower, and use of cell phones was higher on nonbusy roads.

  18. Integrated optical detection of autonomous capillary microfluidic immunoassays:a hand-held point-of-care prototype.

    Science.gov (United States)

    Novo, P; Chu, V; Conde, J P

    2014-07-15

    The miniaturization of biosensors using microfluidics has potential in enabling the development of point-of-care devices, with the added advantages of reduced time and cost of analysis with limits-of-detection comparable to those obtained through traditional laboratory techniques. Interfacing microfluidic devices with the external world can be difficult especially in aspects involving fluid handling and the need for simple sample insertion that avoids special equipment or trained personnel. In this work we present a point-of-care prototype system by integrating capillary microfluidics with a microfabricated photodiode array and electronic instrumentation into a hand-held unit. The capillary microfluidic device is capable of autonomous and sequential fluid flow, including control of the average fluid velocity at any given point of the analysis. To demonstrate the functionality of the prototype, a model chemiluminescence ELISA was performed. The performance of the integrated optical detection in the point-of-care prototype is equal to that obtained with traditional bench-top instrumentation. The photodiode signals were acquired, displayed and processed by a simple graphical user interface using a computer connected to the microcontroller through USB. The prototype performed integrated chemiluminescence ELISA detection in about 15 min with a limit-of-detection of ≈2 nM with an antibody-antigen affinity constant of ≈2×10(7) M(-1). Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Performance Analysis of Nomadic Mobile Services on Multi-homed Handheld Devices

    NARCIS (Netherlands)

    Pawar, P.; van Beijnum, Bernhard J.F.; van Sinderen, Marten J.; Aggarwal, Akshai; De Clercq, Frederic

    2007-01-01

    Compared to their predecessors, the current generation handheld mobile devices possess higher processing power, increased memory and new multi-homing capabilities. These features combined with the widespread acceptance and use of these devices result in a situation where mobile devices are no longer

  20. How to use hand-held computers to evaluate wood drying.

    Science.gov (United States)

    Howard N. Rosen; Darrell S. Martin

    1985-01-01

    Techniques have been developed to evaluate end generate wood drying curves with hand-held computers (3-5K memory). Predictions of time to dry to a specific moisture content, drying rates, and other characteristics of wood drying curves can be made. The paper describes the development of programs and illustrates their use.

  1. ENGAGING SCIENCE STUDENTS WITH HANDHELD TECHNOLOGY AND APPLICATIONS BY RE-VISITING THE THAYER METHOD OF TEACHING AND LEARNING

    Directory of Open Access Journals (Sweden)

    Julia Paredes

    2011-12-01

    Full Text Available Organic chemistry instructors integrate handheld technology and applications into course lecture and lab to engage students with tools and techniques students use in the modern world. This technology and applications enable instructors to re-visit the Thayer Method of teaching and learning to create an updated method that works with 21st century students. The Thayer Method is based on the premise that students are willing and capable of making substantial preparation before coming to class and lab in order to maximize efficiency of student-instructor contact time. During this student preparation phase, we engage students with handheld technology and content applications including smart phone viewable course administrative materials; “flashcards” containing basic organic chemistry nomenclature, molecular structures, and chemical reactions; mini-lectures prepared using the Smart Board Airliner Interactive Tablet for upcoming class periods and laboratory technique videos demonstrating tasks they will perform as part of laboratory experimentation. Coupled with a student friendly course text, these handheld applications enable substantial student preparation before class and lab. The method, in conjunction with handheld technology and applications, has been used with positive results in our organic chemistry courses.

  2. The Weak Link HP-41C hand-held calculator program

    Science.gov (United States)

    Ross A. Phillips; Penn A. Peters; Gary D. Falk

    1982-01-01

    The Weak Link hand-held calculator program (HP-41C) quickly analyzes a system for logging production and costs. The production equations model conventional chain saw, skidder, loader, and tandemaxle truck operations in eastern mountain areas. Production of each function of the logging system may be determined so that the system may be balanced for minimum cost. The...

  3. Standardization from a benchtop to a handheld NIR spectrometer using mathematically mixed NIR spectra to determine fuel quality parameters

    DEFF Research Database (Denmark)

    da Silva, Neirivaldo Cavalcante; Cavalcanti, Claudia Jessica; Honorato, Fernanda Araujo

    2017-01-01

    spectral responses of fuel samples (gasoline and biodiesel blends) from a high-resolution benchtop Frontier FT-NIR (PerkinElmer) spectrometer and a handheld MicroNIR™1700 (JDSU). These virtual standards can be created by mathematically mixing spectra from the pure solvents present in gasoline or diesel...... to the handheld MicroNIR using virtual standards as transfer samples...

  4. Development of dual sensor hand-held detector

    Science.gov (United States)

    Sezgin, Mehmet

    2010-04-01

    In this paper hand-held dual sensor detector development requirements are considered dedicated to buried object detection. Design characteristics of such a system are categorized and listed. Hardware and software structures, ergonomics, user interface, environmental and EMC/EMI tests to be applied and performance test issues are studied. Main properties of the developed system (SEZER) are presented, which contains Metal Detector (MD) and Ground Penetrating Radar (GPR). The realized system has ergonomic structure and can detect both metallic and non-metallic buried objects. Moreover classification of target is possible if it was defined to the signal processing software in learning phase.

  5. Reusable Handheld Electrolytes and Lab Technology for Humans (rHEALTH Sensor), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of rHEALTH sensor is a universal handheld sensor that can provide rapid, low-cost complete blood count (CBC) with differential, electrolyte analysis, and...

  6. Reusable Handheld Electrolytes and Lab Technology for Humans (rHEALTH Sensor), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of the rHEALTH sensor is to provide rapid, low-cost, handheld complete blood count (CBC), cell differential counts, electrolyte measurements, and other lab...

  7. PROSPECTIVE EVALUATION OF VISUAL ACUITY AGREEMENT BETWEEN STANDARD EARLY TREATMENT DIABETIC RETINOPATHY STUDY CHART AND A HANDHELD EQUIVALENT IN EYES WITH RETINAL PATHOLOGY.

    Science.gov (United States)

    Rahimy, Ehsan; Reddy, Sahitya; DeCroos, Francis Char; Khan, M Ali; Boyer, David S; Gupta, Omesh P; Regillo, Carl D; Haller, Julia A

    2015-08-01

    To evaluate the visual acuity agreement between a standard back-illuminated Early Treatment Diabetic Retinopathy Study (ETDRS) chart and a handheld internally illuminated ETDRS chart. Two-center prospective study. Seventy patients (134 eyes) with retinal pathology were enrolled between October 2012 and August 2013. Visual acuity was measured using both the ETDRS chart and the handheld device by masked independent examiners after best protocol refraction. Examination was performed in the same room under identical illumination and testing conditions. The mean number of letters seen was 63.0 (standard deviation: 19.8 letters) and 61.2 letters (standard deviation: 19.1 letters) for the ETDRS chart and handheld device, respectively. Mean difference per eye between the ETDRS and handheld device was 1.8 letters. A correlation coefficient (r) of 0.95 demonstrated a positive linear correlation between ETDRS chart and handheld device measured acuities. Intraclass correlation coefficient was performed to assess the reproducibility of the measurements made by different observers measuring the same quantity and was calculated to be 0.95 (95% confidence interval: 0.93-0.96). Agreement was independent of retinal disease. The strong correlation between measured visual acuity using the ETDRS and handheld equivalent suggests that they may be used interchangeably, with accurate measurements. Potential benefits of this device include convenience and portability, as well as the ability to assess ETDRS visual acuity without a dedicated testing lane.

  8. Gen-2 Hand-Held Optical Imager towards Cancer Imaging: Reflectance and Transillumination Phantom Studies

    Directory of Open Access Journals (Sweden)

    Anuradha Godavarty

    2012-02-01

    Full Text Available Hand-held near-infrared (NIR optical imagers are developed by various researchers towards non-invasive clinical breast imaging. Unlike these existing imagers that can perform only reflectance imaging, a generation-2 (Gen-2 hand-held optical imager has been recently developed to perform both reflectance and transillumination imaging. The unique forked design of the hand-held probe head(s allows for reflectance imaging (as in ultrasound and transillumination or compressed imaging (as in X-ray mammography. Phantom studies were performed to demonstrate two-dimensional (2D target detection via reflectance and transillumination imaging at various target depths (1–5 cm deep and using simultaneous multiple point illumination approach. It was observed that 0.45 cc targets were detected up to 5 cm deep during transillumination, but limited to 2.5 cm deep during reflectance imaging. Additionally, implementing appropriate data post-processing techniques along with a polynomial fitting approach, to plot 2D surface contours of the detected signal, yields distinct target detectability and localization. The ability of the gen-2 imager to perform both reflectance and transillumination imaging allows its direct comparison to ultrasound and X-ray mammography results, respectively, in future clinical breast imaging studies.

  9. The reliability and validity of hand-held refractometry water content measures of hydrogel lenses.

    Science.gov (United States)

    Nichols, Jason J; Mitchell, G Lynn; Good, Gregory W

    2003-06-01

    To investigate within- and between-examiner reliability and validity of hand-held refractometry water content measures of hydrogel lenses. Nineteen lenses of various nominal water contents were examined by two examiners on two occasions separated by 1 hour. An Atago N2 hand-held refractometer was used for all water content measures. Lenses were presented in a random order to each examiner by a third party, and examiners were masked to any potential lens identifiers. Intraclass correlation coefficients (ICC), 95% limits of agreement, and Wilcoxon signed rank test were used to characterize the within- and between-examiner reliability and validity of lens water content measures. Within-examiner reliability was excellent (ICC, 0.97; 95% limits of agreement, -3.6% to +5.7%), and the inter-visit mean difference of 1.1 +/- 2.4% was not biased (p = 0.08). Between-examiner reliability was also excellent (ICC, 0.98; 95% limits of agreement, -4.1% to +3.9%). The mean difference between examiners was -0.1 +/- 2.1% (p = 0.83). The mean difference between the nominally reported water content and our water content measures was -2.1 +/- 1.7% (p refractometry and is material dependent. Therefore, investigators may need to account for bias when measuring hydrogel lens water content via hand-held refractometry.

  10. Development of international standards for instrumentation used for detection of illicit trafficking of radioactive material

    International Nuclear Information System (INIS)

    Voytchev, M.; Chiaro, P.; Radev, R.

    2006-01-01

    Subcommittee 45 B 'Radiation Protection Instrumentation' of the International Electrotechnical Commission (I.E.C.) is charged with the development of international standards for instrumentation used for monitoring of illicit trafficking of radioactive material through international boarders and territories, as well as inside countries. Currently three I.E.C. standards are in advanced stages of development. They are expected to be approved and published in 2006-2007. The international participation and the main characteristics of the following three standards are discussed and presented: I.E.C. 62327 'Hand-held Instruments for the Detection and Identification of Radionuclides and Additionally for the Indication of Ambient Dose Equivalent Rate from Photon Radiation', I.E.C. 62401 'Alarming Personal Radiation Devices for Detection of Illicit Trafficking of Radioactive Material' and I.E.C. 62244 'Installed Radiation Monitors for the Detection of Radioactive and Special Nuclear Materials at National Borders'

  11. Maintaining radiation exposures as low as reasonably achievable (ALARA) for dental personnel operating portable hand-held x-ray equipment.

    Science.gov (United States)

    McGiff, Thomas J; Danforth, Robert A; Herschaft, Edward E

    2012-08-01

    Clinical experience indicates that newly available portable hand-held x-ray units provide advantages compared to traditional fixed properly installed and operated x-ray units in dental radiography. However, concern that hand-held x-ray units produce higher operator doses than fixed x-ray units has caused regulatory agencies to mandate requirements for use of hand-held units that go beyond those recommended by the manufacturer and can discourage the use of this technology. To assess the need for additional requirements, a hand-held x-ray unit and a pair of manikins were used to measure the dose to a simulated operator under two conditions: exposures made according to the manufacturer's recommendations and exposures made according to manufacturer's recommendation except for the removal of the x-ray unit's protective backscatter shield. Dose to the simulated operator was determined using an array of personal dosimeters and a pair of pressurized ion chambers. The results indicate that the dose to an operator of this equipment will be less than 0.6 mSv y⁻¹ if the device is used according to the manufacturer's recommendations. This suggests that doses to properly trained operators of well-designed, hand-held dental x-ray units will be below 1.0 mSv y⁻¹ (2% of the annual occupational dose limit) even if additional no additional operational requirements are established by regulatory agencies. This level of annual dose is similar to those reported as typical dental personnel using fixed x-ray units and appears to satisfy the ALARA principal for this class of occupational exposures.

  12. Application of Suresight handheld auto-refractometer in refraction screening for infants in Community Health Service Center

    Directory of Open Access Journals (Sweden)

    Li-Hua Guo

    2014-08-01

    Full Text Available AIM: To observe the application of Suresight handheld auto-refractometer in measuring diopter of infants in Community Health Service Center. METHODS:Totally 836 cases(1 672 eyesfrom June 2013 to December 2013 were examined diopter of infants by Suresight handheld auto-refractometer in Community Health Service Center. RESULTS: Within 1 672 eyes of 836 infants were examined, 202 eyes were diagnosed ametropia, 38 eyes were suspicious, 240 eyes were transferred to the department of ophthalmology, the referral rate was 14.35%; 172 eyes were diagnosed ametropia, and the diagnosis rate of the referral patients was 71.67%. Among 172 eyes, 46 eyes were provided with corrected glasses, accounting for 2.75% of the number of screening, and 126 eyes were given intensive monitoring, accounting for 7.54% of the number of screening.CONCLUSION: Application of Suresight handheld auto-refractometer in refraction screening for infants in Community Health Service Center is convenient and effective. With two-way referral between community health service center and department of ophthalmology can monitor and intervene vision development of infants much earlier.

  13. Handheld skin printer: in situ formation of planar biomaterials and tissues.

    Science.gov (United States)

    Hakimi, Navid; Cheng, Richard; Leng, Lian; Sotoudehfar, Mohammad; Ba, Phoenix Qing; Bakhtyar, Nazihah; Amini-Nik, Saeid; Jeschke, Marc G; Günther, Axel

    2018-05-15

    We present a handheld skin printer that enables the in situ formation of biomaterial and skin tissue sheets of different homogeneous and architected compositions. When manually positioned above a target surface, the compact instrument (weight <0.8 kg) conformally deposits a biomaterial or tissue sheet from a microfluidic cartridge. Consistent sheet formation is achieved by coordinating the flow rates at which bioink and cross-linker solution are delivered, with the speed at which a pair of rollers actively translate the cartridge along the surface. We demonstrate compatibility with dermal and epidermal cells embedded in ionically cross-linkable biomaterials (e.g., alginate), and enzymatically cross-linkable proteins (e.g., fibrin), as well as their mixtures with collagen type I and hyaluronic acid. Upon rapid crosslinking, biomaterial and skin cell-laden sheets of consistent thickness, width and composition were obtained. Sheets deposited onto horizontal, agarose-coated surfaces were used for physical and in vitro characterization. Proof-of-principle demonstrations for the in situ formation of biomaterial sheets in murine and porcine excisional wound models illustrate the capacity of depositing onto inclined and compliant wound surfaces that are subject to respiratory motion. We expect the presented work will enable the in situ delivery of a wide range of different cells, biomaterials, and tissue adhesives, as well as the in situ fabrication of spatially organized biomaterials, tissues, and biohybrid structures.

  14. A Handheld, Free Roaming, Data Display for DIII-D Diagnostic Data

    International Nuclear Information System (INIS)

    Broesch, J.D.; Phillips, J.C.; Petersen, P.I.; Hansink, M.J.

    1999-01-01

    Standard handheld test instruments such as voltmeters and portable oscilloscopes are useful for making basic measurements necessary for the operation and maintenance of large experiments such as the DIII-D magnetic fusion research facility. Some critical diagnostic information, however, is available only on system computers. Often this diagnostic information is located in computer databases and requires synthesis via computational algorithms to be of practical use to the technician. Unfortunately, this means the data is typically only available via computer screens located at fixed locations. One common way to provide mobile information is to have one operator sit at a console and read the data to the mobile technician via radio. This is inefficient in as much as it requires two people. Even more importantly the operator-to-technician voice link introduces significant delays and errors that may hinder response times. To address these concerns of personnel utilization and efficiency, we have developed a remote display based on an rf-data link that can be carried with a technician as he moves about the facility. This display can provide the technician with any information needed from the stationary database. This paper will discuss the overall architecture as well as the individual modules for the mobile data display. Lessons learned, as well as techniques for improving the usefulness of such systems, will be presented

  15. Classification and Visualization of Physical and Chemical Properties of Falsified Medicines with Handheld Raman Spectroscopy and X-Ray Computed Tomography.

    Science.gov (United States)

    Kakio, Tomoko; Yoshida, Naoko; Macha, Susan; Moriguchi, Kazunobu; Hiroshima, Takashi; Ikeda, Yukihiro; Tsuboi, Hirohito; Kimura, Kazuko

    2017-09-01

    Analytical methods for the detection of substandard and falsified medical products (SFs) are important for public health and patient safety. Research to understand how the physical and chemical properties of SFs can be most effectively applied to distinguish the SFs from authentic products has not yet been investigated enough. Here, we investigated the usefulness of two analytical methods, handheld Raman spectroscopy (handheld Raman) and X-ray computed tomography (X-ray CT), for detecting SFs among oral solid antihypertensive pharmaceutical products containing candesartan cilexetil as an active pharmaceutical ingredient (API). X-ray CT visualized at least two different types of falsified tablets, one containing many cracks and voids and the other containing aggregates with high electron density, such as from the presence of the heavy elements. Generic products that purported to contain equivalent amounts of API to the authentic products were discriminated from the authentic products by the handheld Raman and the different physical structure on X-ray CT. Approach to investigate both the chemical and physical properties with handheld Raman and X-ray CT, respectively, promise the accurate discrimination of the SFs, even if their visual appearance is similar with authentic products. We present a decision tree for investigating the authenticity of samples purporting to be authentic commercial tablets. Our results indicate that the combination approach of visual observation, handheld Raman and X-ray CT is a powerful strategy for nondestructive discrimination of suspect samples.

  16. Adaptive RF front-ends for hand-held applications

    CERN Document Server

    van Bezooijen, Andre; van Roermund, Arthur

    2010-01-01

    The RF front-end - antenna combination is a vital part of a mobile phone because its performance is very relevant to the link quality between hand-set and cellular network base-stations. The RF front-end performance suffers from changes in operating environment, like hand-effects, that are often unpredictable. ""Adaptive RF Front-Ends for Hand-Held Applications"" presents an analysis on the impact of fluctuating environmental parameters. In order to overcome undesired behavior two different adaptive control methods are treated that make RF frond-ends more resilient: adaptive impedance control,

  17. Handheld Longwave Infrared Camera Based on Highly-Sensitive Quantum Well Infrared Photodetectors, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop a compact handheld longwave infrared camera based on quantum well infrared photodetector (QWIP) focal plane array (FPA) technology. Based on...

  18. A data-driven design evaluation tool for handheld device soft keyboards.

    Directory of Open Access Journals (Sweden)

    Matthieu B Trudeau

    Full Text Available Thumb interaction is a primary technique used to operate small handheld devices such as smartphones. Despite the different techniques involved in operating a handheld device compared to a personal computer, the keyboard layouts for both devices are similar. A handheld device keyboard that considers the physical capabilities of the thumb may improve user experience. We developed and applied a design evaluation tool for different geometries of the QWERTY keyboard using a performance evaluation model. The model utilizes previously collected data on thumb motor performance and posture for different tap locations and thumb movement directions. We calculated a performance index (PITOT, 0 is worst and 2 is best for 663 designs consisting in different combinations of three variables: the keyboard's radius of curvature (R (mm, orientation (O (°, and vertical location on the screen (L. The current standard keyboard performed poorly (PITOT = 0.28 compared to other designs considered. Keyboard location (L contributed to the greatest variability in performance out of the three design variables, suggesting that designers should modify this variable first. Performance was greatest for designs in the middle keyboard location. In addition, having a slightly upward curve (R = -20 mm and orientated perpendicular to the thumb's long axis (O = -20° improved performance to PITOT = 1.97. Poorest performances were associated with placement of the keyboard's spacebar in the bottom right corner of the screen (e.g., the worst was for R = 20 mm, O = 40°, L =  Bottom (PITOT = 0.09. While this evaluation tool can be used in the design process as an ergonomic reference to promote user motor performance, other design variables such as visual access and usability still remain unexplored.

  19. Comparative Geometrical Accuracy Investigations of Hand-Held 3d Scanning Systems - AN Update

    Science.gov (United States)

    Kersten, T. P.; Lindstaedt, M.; Starosta, D.

    2018-05-01

    Hand-held 3D scanning systems are increasingly available on the market from several system manufacturers. These systems are deployed for 3D recording of objects with different size in diverse applications, such as industrial reverse engineering, and documentation of museum exhibits etc. Typical measurement distances range from 0.5 m to 4.5 m. Although they are often easy-to-use, the geometric performance of these systems, especially the precision and accuracy, are not well known to many users. First geometrical investigations of a variety of diverse hand-held 3D scanning systems were already carried out by the Photogrammetry & Laser Scanning Lab of the HafenCity University Hamburg (HCU Hamburg) in cooperation with two other universities in 2016. To obtain more information about the accuracy behaviour of the latest generation of hand-held 3D scanning systems, HCU Hamburg conducted further comparative geometrical investigations using structured light systems with speckle pattern (Artec Spider, Mantis Vision PocketScan 3D, Mantis Vision F5-SR, Mantis Vision F5-B, and Mantis Vision F6), and photogrammetric systems (Creaform HandySCAN 700 and Shining FreeScan X7). In the framework of these comparative investigations geometrically stable reference bodies were used. The appropriate reference data was acquired by measurements with two structured light projection systems (AICON smartSCAN and GOM ATOS I 2M). The comprehensive test results of the different test scenarios are presented and critically discussed in this contribution.

  20. A Fresh Look at the Crystal Violet Lab with Handheld Camera Colorimetry

    Science.gov (United States)

    Knutson, Theodore R.; Knutson, Cassandra M.; Mozzetti, Abbie R.; Campos, Antonio R.; Haynes, Christy L.; Penn, R. Lee

    2015-01-01

    Chemical kinetic experiments to determine rate laws are common in high school and college chemistry courses. For reactions involving a color change, rate laws can be determined experimentally using spectrophotometric or colorimetric equipment though this equipment can be cost prohibitive. Previous work demonstrated that inexpensive handheld camera…

  1. Torque Removal Evaluation of Screw in One-Piece and Two-Piece Abutments Tightened with a Handheld screwdriver

    Directory of Open Access Journals (Sweden)

    Jalil Ghanbarzadeh

    2013-12-01

    Full Text Available Introduction: Some clinicians use a handheld screw driver instead of a torque wrench to definitively tighten abutment screws. The aim of this study was to compare the removal torque of one-piece and two-piece abutments tightened with a handheld driver and a torque control ratchet. Methods: 40 ITI implants were placed in acrylic blocks and divided into 4 groups. In groups one and two, 10 ITI one-piece abutments (Solid® and in groups three and four, 10 ITI two-piece abutments (Synocta® were placed on the implants. In groups one and three abutments were tightened by 5 experienced males and 5 experienced females using a handheld driver. In groups two and four abutments were tightened using a torque wrench with torque values of 10, 20 and 35 N.cm. Insertion torque and removal torque values of the abutments were measured with a digital torque meter. Results: The insertion torque values (ITVs of males in both abutments were significantly higher than those of females. ITVs in both Solid® and Synocta® abutments tightened with a handheld screwdriver were similar to the torque of 20 N.cm in the torque wrench. Removal torque values (RTVs of solid® abutments were higher than those of synocta® abutments. Conclusion: The one- piece abutments (solid® showed higher RTVs than the two-piece abutments (synocta®. Hand driver does not produce sufficient preload force for the final tightening of the abutment

  2. The Use of Handheld X-Ray Fluorescence (XRF) Technology in Unraveling the Eruptive History of the San Francisco Volcanic Field, Arizona

    Science.gov (United States)

    Young, Kelsey E.; Evans, C. A.; Hodges, K. V.

    2012-01-01

    While traditional geologic mapping includes the examination of structural relationships between rock units in the field, more advanced technology now enables us to simultaneously collect and combine analytical datasets with field observations. Information about tectonomagmatic processes can be gleaned from these combined data products. Historically, construction of multi-layered field maps that include sample data has been accomplished serially (first map and collect samples, analyze samples, combine data, and finally, readjust maps and conclusions about geologic history based on combined data sets). New instruments that can be used in the field, such as a handheld xray fluorescence (XRF) unit, are now available. Targeted use of such instruments enables geologists to collect preliminary geochemical data while in the field so that they can optimize scientific data return from each field traverse. Our study tests the application of this technology and projects the benefits gained by real-time geochemical data in the field. The integrated data set produces a richer geologic map and facilitates a stronger contextual picture for field geologists when collecting field observations and samples for future laboratory work. Real-time geochemical data on samples also provide valuable insight regarding sampling decisions by the field geologist

  3. Handheld Delivery System for Modified Boron-Type Fire Extinguishment Agent

    Science.gov (United States)

    1993-11-01

    was to develop and test a handheld portable delivery system for use with the modified boron-type fire extinguishing agent for metal fires . B...BACKGROUND A need exists for an extinguishing agent and accompanying delivery system that are effective against complex geometry metal fires . A modified...agent and its delivery system have proven effective against complex geometry metal fires containing up to 200 pounds of magnesium metal. Further

  4. Handheld microwave bomb-detecting imaging system

    Science.gov (United States)

    Gorwara, Ashok; Molchanov, Pavlo

    2017-05-01

    Proposed novel imaging technique will provide all weather high-resolution imaging and recognition capability for RF/Microwave signals with good penetration through highly scattered media: fog, snow, dust, smoke, even foliage, camouflage, walls and ground. Image resolution in proposed imaging system is not limited by diffraction and will be determined by processor and sampling frequency. Proposed imaging system can simultaneously cover wide field of view, detect multiple targets and can be multi-frequency, multi-function. Directional antennas in imaging system can be close positioned and installed in cell phone size handheld device, on small aircraft or distributed around protected border or object. Non-scanning monopulse system allows dramatically decrease in transmitting power and at the same time provides increased imaging range by integrating 2-3 orders more signals than regular scanning imaging systems.

  5. Development of a miRNA surface-enhanced Raman scattering assay using benchtop and handheld Raman systems.

    Science.gov (United States)

    Schechinger, Monika; Marks, Haley; Locke, Andrea; Choudhury, Mahua; Cote, Gerard

    2018-01-01

    DNA-functionalized nanoparticles, when paired with surface-enhanced Raman spectroscopy (SERS), can rapidly detect microRNA. However, widespread use of this approach is hindered by drawbacks associated with large and expensive benchtop Raman microscopes. MicroRNA-17 (miRNA-17) has emerged as a potential epigenetic indicator of preeclampsia, a condition that occurs during pregnancy. Biomarker detection using an SERS point-of-care device could enable prompt diagnosis and prevention as early as the first trimester. Recently, strides have been made in developing portable Raman systems for field applications. An SERS assay for miRNA-17 was assessed and translated from traditional benchtop Raman microscopes to a handheld system. Three different photoactive molecules were compared as potential Raman reporter molecules: a chromophore, malachite green isothiocyanate (MGITC), a fluorophore, tetramethylrhodamine isothiocyanate, and a polarizable small molecule 5,5-dithio-bis-(2-nitrobenzoic acid) (DTNB). For the benchtop Raman microscope, the DTNB-labeled assay yielded the greatest sensitivity under 532-nm laser excitation, but the MGITC-labeled assay prevailed at 785 nm. Conversely, DTNB was preferable for the miniaturized 785-nm Raman system. This comparison showed significant SERS enhancement variation in response to 1-nM miRNA-17, implying that the sensitivity of the assay may be more heavily dependent on the excitation wavelength, instrumentation, and Raman reporter chosen than on the plasmonic coupling from DNA/miRNA-mediated nanoparticle assemblies. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  6. Handheld Versus Wearable Interaction Design for Professionals - A Case Study of Hospital Service Work

    DEFF Research Database (Denmark)

    Stisen, Allan; Blunck, Henrik; Kjærgaard, Mikkel Baun

    2014-01-01

    With the blooming of new available wrist worn devices there are potentials for these to support the work done in many professional domains. One such domain is hospital service work. This paper explores two wearable prototypes with regards to challenges and opportunities to support future hospital...... service work. This explorative study was conducted with 4 experienced hospital orderlies who interacted with an application across two wearable concepts, and one handheld smartphone in five scenarios in a hospital environment. The interaction was video recorded with a chest-mounted video afterwards semi...... structured interviews with each participant was conducted. This study shows that wearable computers can effectively support the maintenance work of the orderlies and has domain specific advantages over the handheld smartphone, e.g., the former support glancing at the task information. Furthermore, we outline...

  7. [Evaluation of accuracy of measuring intraocular pressure by handheld non-contact applanation tonometer].

    Science.gov (United States)

    Chen, X; Peng, D; Zhou, W; Zhong, Y

    1995-06-01

    To evaluate the accuracy of measuring intraocular pressure by handheld non-contact applanation tonometer. 58 patients' (113 eyes) intraocular pressure were measured by Keeler, non-contact tonometer and R 900 Goldmann applanation tonometer and the results of measurement of intraocular pressure by the two kinds of tonometers were compared. The mean intraocular pressure measured by non-contact is 16.31 +/- 5.59 mmHg and 17.49 +/- 6.13 mmHg (1 mmHg = 0.1333 kPa) by Goldmann applanation tonometer, respectively. There was no statistical significance to be found (P > 0.05) between the two methods. By linear correlation and regression analysis, a positive correlation was found between the two methods (r = 0.8942, b = 0.8154). The handheld non-contact tonometer has the same accuracy and reliability of measurement of intraocular pressure comparing with Goldmann applanation tonometer, and it can be used in glaucoma clinic and screening.

  8. Handheld pose tracking using vision-inertial sensors with occlusion handling

    Science.gov (United States)

    Li, Juan; Slembrouck, Maarten; Deboeverie, Francis; Bernardos, Ana M.; Besada, Juan A.; Veelaert, Peter; Aghajan, Hamid; Casar, José R.; Philips, Wilfried

    2016-07-01

    Tracking of a handheld device's three-dimensional (3-D) position and orientation is fundamental to various application domains, including augmented reality (AR), virtual reality, and interaction in smart spaces. Existing systems still offer limited performance in terms of accuracy, robustness, computational cost, and ease of deployment. We present a low-cost, accurate, and robust system for handheld pose tracking using fused vision and inertial data. The integration of measurements from embedded accelerometers reduces the number of unknown parameters in the six-degree-of-freedom pose calculation. The proposed system requires two light-emitting diode (LED) markers to be attached to the device, which are tracked by external cameras through a robust algorithm against illumination changes. Three data fusion methods have been proposed, including the triangulation-based stereo-vision system, constraint-based stereo-vision system with occlusion handling, and triangulation-based multivision system. Real-time demonstrations of the proposed system applied to AR and 3-D gaming are also included. The accuracy assessment of the proposed system is carried out by comparing with the data generated by the state-of-the-art commercial motion tracking system OptiTrack. Experimental results show that the proposed system has achieved high accuracy of few centimeters in position estimation and few degrees in orientation estimation.

  9. Radiation safety evaluation of a hand-held, battery operated image intensifier

    International Nuclear Information System (INIS)

    Wilson, O.J.; Young, B.F.

    1987-01-01

    A portable, hand-held, fluoroscopic unit intended for medical and industrial use was tested to verify the claim of the manufacturers that the radiation doses to the patient and user are low, and comparable to those received from standard radiographic procedures. The first claim was substantiated but not the second. A number of concerns arising from the use of this unit are discussed

  10. Efficacy of Handheld Electronic Visual Supports to Enhance Vocabulary in Children with ASD

    Science.gov (United States)

    Ganz, Jennifer B.; Boles, Margot B.; Goodwyn, Fara D.; Flores, Margaret M.

    2014-01-01

    Although electronic tools such as handheld computers have become increasingly common throughout society, implementation of such tools to improve skills in individuals with intellectual and developmental disabilities has lagged in the professional literature. However, the use of visual scripts for individuals with disabilities, particularly those…

  11. Field-portable high-resolution EDXRF analysis with HgI2-detector-based instrumentation

    International Nuclear Information System (INIS)

    Berry, P.F.; Little, S.R.; Voots, G.R.

    1992-01-01

    Energy dispersive x-ray fluorescence (EDXRF) analysis is well known for its efficient use of x-ray detector technology for simultaneous multielement determination. Low-intensity excitation, such as from a radioisotope source, can thus be employed and has enabled the design of many types of truly portable EDXRF instrumentation. Portable design, however, has not been without significant compromise in analytical performance because of the limited x-ray resolving power of prior detection methods, except by the use of a cryogenically operated detector. The developments we refer to stem from the use of a comparatively new x-ray detection device fabricated from mercuric iodide (HgI 2 ). For this detector, only a modest degree of cooling is required to achieve an energy resolution of > 300 eV. Two field-portable instrument designs of different hand-held measurement probe configurations are available that have applications for industrial quality assurance and environmental screening

  12. A study of cladding technology on tube wall surface by a hand-held laser torch

    International Nuclear Information System (INIS)

    Terada, Takaya; Nishimura, Akihiko; Oka, Kiyoshi; Moriyama, Taku; Matsuda, Hiroyasu

    2015-01-01

    New maintenance technique was proposed using a hand-held laser torch for aging chemical plants and power plants. The hand-held laser torch was specially designed to be able to access limited tubular space in various cases. A composite-type optical fiberscope was composed of a center fiber for beam delivery and surrounded fibers for visible image delivery. Laser irradiation on a work pieces with the best accuracy of filler wire was carried out. And, we found that the optimized wire-feed speed was 2 mm/s in laser cladding. We succeeded to make a line clad on the inner wall of 23 mm tube. This technique was discussed to be applied to the maintenance for cracks or corrosions of tubes in various harsh environments. (author)

  13. Evolving Consumption Patterns of Various Information Media via Handheld Mobile Devices

    Directory of Open Access Journals (Sweden)

    Nitza Geri

    2015-06-01

    Full Text Available This study examines diverse information media in order to identify those formats that are most suitable for consumption via handheld mobile devices, namely, smartphones and tablets. The preferences of the users are measured objectively by analyzing actual data of their relative use of handheld mobile devices and personal computing (PC desktop devices, including laptops and notebooks, for consumption of information presented in various formats. Our findings are based on Google Analytics pageview data of five course Websites during a period of three semesters, by 11,557 undergraduate students. M-learning contexts were chosen, since in a learning environment the interests of information providers (i.e., the instructors are in accord with those of the information consumers (i.e., the students, whereas in commercial settings there may be conflicts of interests. Our findings demonstrate that although about 90% of the pageviews were via PC devices, the rate of smartphone use for consuming learning content in diverse information media is gradually increasing as time goes by, whereas the rate of tablet use for these purposes is stagnant. The most promising direction for smartphone development, emanating from the findings, is online video content.

  14. Hand-held indirect calorimeter offers advantages compared with prediction equations, in a group of overweight women, to determine resting energy expenditures and estimated total energy expenditures during research screening.

    Science.gov (United States)

    Spears, Karen E; Kim, Hyunsook; Behall, Kay M; Conway, Joan M

    2009-05-01

    To compare standardized prediction equations to a hand-held indirect calorimeter in estimating resting energy and total energy requirements in overweight women. Resting energy expenditure (REE) was measured by hand-held indirect calorimeter and calculated by prediction equations Harris-Benedict, Mifflin-St Jeor, World Health Organization/Food and Agriculture Organization/United Nations University (WHO), and Dietary Reference Intakes (DRI). Physical activity level, assessed by questionnaire, was used to estimate total energy expenditure (TEE). Subjects (n=39) were female nonsmokers older than 25 years of age with body mass index more than 25. Repeated measures analysis of variance, Bland-Altman plot, and fitted regression line of difference. A difference within +/-10% of two methods indicated agreement. Significant proportional bias was present between hand-held indirect calorimeter and prediction equations for REE and TEE (Pvalues and underestimated at higher values. Mean differences (+/-standard error) for REE and TEE between hand-held indirect calorimeter and Harris-Benedict were -5.98+/-46.7 kcal/day (P=0.90) and 21.40+/-75.7 kcal/day (P=0.78); between hand-held indirect calorimeter and Mifflin-St Jeor were 69.93+/-46.7 kcal/day (P=0.14) and 116.44+/-75.9 kcal/day (P=0.13); between hand-held indirect calorimeter and WHO were -22.03+/-48.4 kcal/day (P=0.65) and -15.8+/-77.9 kcal/day (P=0.84); and between hand-held indirect calorimeter and DRI were 39.65+/-47.4 kcal/day (P=0.41) and 56.36+/-85.5 kcal/day (P=0.51). Less than 50% of predictive equation values were within +/-10% of hand-held indirect calorimeter values, indicating poor agreement. A significant discrepancy between predicted and measured energy expenditure was observed. Further evaluation of hand-held indirect calorimeter research screening is needed.

  15. Handheld Multi-Gas Meters Assessment Report

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Gustavious [Brigham Young Univ., Provo, UT (United States); Wald-Hopkins, Mark David [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Obrey, Stephen J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Akhadov, Valida Dushdurova [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-27

    Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the monitored chemical. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. In April 2016 the System Assessment and Validation for Emergency Responders (SAVER) Program conducted an operationally-oriented assessment of MGMs. Five MGMs were assessed by emergency responders. The criteria and scenarios used in this assessment were derived from the results of a focus group of emergency responders with experience in using MGMs. The assessment addressed 16 evaluation criteria in four SAVER categories: Usability, Capability, Maintainability, and Deployability.

  16. Xsense: using nanotechnology to combine detection methods for high sensitivity handheld explosives detectors

    DEFF Research Database (Denmark)

    Schmidt, Michael Stenbæk; Kostesha, Natalie; Bosco, Filippo

    2010-01-01

    In an effort to produce a handheld explosives sensor the Xsense project has been initiated at the Technical University of Denmark in collaboration with a number of partners. Using micro- and nano technological approaches it will be attempted to integrate four detection principles into a single de...

  17. Standard guide to In-Plant performance evaluation of Hand-Held SNM monitors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This guide is one of a series on the application and evaluation of special nuclear material (SNM) monitors. Other guides in the series are listed in Section 2, and the relationship of in-plant performance evaluation to other procedures described in the series is illustrated in Fig. 1. Hand-held SNM monitors are described in of Guide C1112, and performance criteria illustrating their capabilities can be found in Appendix X1. 1.2 The purpose of this guide to in-plant performance evaluation is to provide a comparatively rapid procedure to verify that a hand-held SNM monitor performs as expected for detecting SNM or alternative test sources or to disclose the need for repair. The procedure can be used as a routine operational evaluation or it can be used to verify performance after a monitor is calibrated. 1.3 In-plant performance evaluations are more comprehensive than daily functional tests. They take place less often, at intervals ranging from weekly to once every three months, and derive their result fr...

  18. Recent technological advancements in laparoscopic surgical instruments

    Science.gov (United States)

    Subido, Edwin D. C.; Pacis, Danica Mitch M.; Bugtai, Nilo T.

    2018-02-01

    Laparoscopy was a progressive step to advancing surgical procedures as it minimised the scars left on the body after surgery, compared to traditional open surgery. Many years later, single-incision laparoscopic surgery (SILS) was created where, instead of having multiple incisions, only one incision is made or multiple small incisions in one location. SILS, or laparoendoscopic single-site surgery (LESS), may produce lesser scars but drawbacks for the surgeons are still present. This paper aims to present related literature of the recent technological developments in laparoscopic tools and procedure particularly in the vision system, handheld instruments. Tech advances in LESS will also be shown. Furthermore, this review intends to give an update on what has been going on in the surgical robot market and state which companies are interested and are developing robotic systems for commercial use to challenge Intuitive Surgical's da Vinci Surgical System that currently dominates the market.

  19. Strength Measurements in Acute Hamstring Injuries: Intertester Reliability and Prognostic Value of Handheld Dynamometry

    NARCIS (Netherlands)

    Reurink, Gustaaf; Goudswaard, Gert Jan; Moen, Maarten H.; Tol, Johannes L.; Verhaar, Jan A. N.; Weir, Adam

    2016-01-01

    Study Design Cohort study, repeated measures. Background Although hamstring strength measurements are used for assessing prognosis and monitoring recovery after hamstring injury, their actual clinical relevance has not been established. Handheld dynamometry (HHD) is a commonly used method of

  20. Epidemiology of Handheld Cell Phone Use While Driving: A Study from a South Indian City.

    Science.gov (United States)

    Majgi, Sumanth Mallikarjuna; AiswaryaLakshmi, A S

    2018-01-01

    Using cell phones while driving contribute to distractions which can potentially cause minor or major road traffic injuries and also stress among other drivers. With this background, the study was done to ascertain the proportion of handheld cell phone use while driving among road users in Mysore city and also patterns of the use by the day of week, type of road, and type of vehicle. The study was conducted in Mysore, Karnataka, India. Four stretches of roads were observed thrice daily for 1 week. The total number of vehicles passing through the stretch and the number and characteristics of drivers using hand-held cell was noted. Pearson's Chi-square test was used to ascertain the significance of the difference in proportions. The overall proportion of cell phone users was calculated as 1.41/100 vehicles. The observed use of handheld cell phones was 1.78 times higher on nonbusy roads than busy roads ( Χ 2 = 25.79, P phone users were driving a two wheeler, the proportion being 50.5% in busy roads, and 67% in nonbusy roads. There was no difference in the proportion of cell phone use by time of the day or across different days of the week. The proportion of drivers who use cell phones is found to be relatively lower, and use of cell phones was higher on nonbusy roads.

  1. Balancing fast-rotating parts of hand-held machine drive

    Science.gov (United States)

    Korotkov, V. S.; Sicora, E. A.; Nadeina, L. V.; Yongzheng, Wang

    2018-03-01

    The article considers the issues related to the balancing of fast rotating parts of the hand-held machine drive including a wave transmission with intermediate rolling elements, which is constructed on the basis of the single-phase collector motor with a useful power of 1 kW and a nominal rotation frequency of 15000 rpm. The forms of balancers and their location are chosen. The method of balancing is described. The scheme for determining of residual unbalance in two correction planes is presented. Measurement results are given in tables.

  2. Comparison of Wearable Optical See-through and Handheld Devices as Platform for an Augmented Reality Museum Guide

    DEFF Research Database (Denmark)

    Serubugo, Sule; Skantarova, Denisa; Nielsen, Lasse Kjærsgård

    2017-01-01

    Self-service guides are a common way of providing information about artworks exhibited in museums. Modern advances in handheld mobile applications and wearable optical see-through devices that use augmented reality offer new ways of designing museum guides that are more engaging and interactive...... than traditional self-service guides such as written descriptions or audio guides. In this study we compare wearable (smart glasses) and handheld (smartphone) devices as a platform for an augmented reality museum guide. We have developed a museum guide for both a smartphone and smart glasses that can...... of potentials of these platforms as augmented reality museum guides and suggest promising future work....

  3. Hand-held cell phone use while driving legislation and observed driver behavior among population sub-groups in the United States

    OpenAIRE

    Rudisill, Toni M.; Zhu, Motao

    2017-01-01

    Abstract Background Cell phone use behaviors are known to vary across demographic sub-groups and geographic locations. This study examined whether universal hand-held calling while driving bans were associated with lower road-side observed hand-held cell phone conversations across drivers of different ages (16–24, 25–59, ≥60 years), sexes, races (White, African American, or other), ruralities (suburban, rural, or urban), and regions (Northeast, Midwest, South, and West). Methods Data from the...

  4. Effects of a Driver Cellphone Ban on Overall, Handheld, and Hands-Free Cellphone Use While Driving: New Evidence from Canada.

    Science.gov (United States)

    Carpenter, Christopher S; Nguyen, Hai V

    2015-11-01

    We provide new evidence on the effects of increasingly common driver cellphone bans on self-reported overall, handheld, and hands-free cellphone use while driving by studying Ontario, Canada, which instituted a 3-month education campaign in November 2009 followed by a binding driver cellphone ban in February 2010. Using residents of Alberta as a control group in a difference-in-differences framework, we find visual and regression-based evidence that Ontario's cellphone ban significantly reduced overall and handheld cellphone use. We also find that the policies significantly increased hands-free cellphone use. The reductions in overall and handheld use are driven exclusively by women, whereas the increases in hands-free use are much larger for men. Our results provide the first direct evidence that cellphone bans have the unintended effect of inducing substitution to hands-free devices. Copyright © 2014 John Wiley & Sons, Ltd.

  5. Detection of fecal contamination on beef meat surfaces using handheld fluorescence imaging device (HFID)

    Science.gov (United States)

    Current meat inspection in slaughter plants, for food safety and quality attributes including potential fecal contamination, is conducted through by visual examination human inspectors. A handheld fluorescence-based imaging device (HFID) was developed to be an assistive tool for human inspectors by ...

  6. Evaluation of a focussed protocol for hand-held echocardiography and computer-assisted auscultation in detecting latent rheumatic heart disease in scholars.

    Science.gov (United States)

    Zühlke, Liesl J; Engel, Mark E; Nkepu, Simpiwe; Mayosi, Bongani M

    2016-08-01

    Introduction Echocardiography is the diagnostic test of choice for latent rheumatic heart disease. The utility of echocardiography for large-scale screening is limited by high cost, complex diagnostic protocols, and time to acquire multiple images. We evaluated the performance of a brief hand-held echocardiography protocol and computer-assisted auscultation in detecting latent rheumatic heart disease with or without pathological murmur. A total of 27 asymptomatic patients with latent rheumatic heart disease based on the World Heart Federation criteria and 66 healthy controls were examined by standard cardiac auscultation to detect pathological murmur. Hand-held echocardiography using a focussed protocol that utilises one view - that is, the parasternal long-axis view - and one measurement - that is, mitral regurgitant jet - and a computer-assisted auscultation utilising an automated decision tool were performed on all patients. The sensitivity and specificity of computer-assisted auscultation in latent rheumatic heart disease were 4% (95% CI 1.0-20.4%) and 93.7% (95% CI 84.5-98.3%), respectively. The sensitivity and specificity of the focussed hand-held echocardiography protocol for definite rheumatic heart disease were 92.3% (95% CI 63.9-99.8%) and 100%, respectively. The test reliability of hand-held echocardiography was 98.7% for definite and 94.7% for borderline disease, and the adjusted diagnostic odds ratios were 1041 and 263.9 for definite and borderline disease, respectively. Computer-assisted auscultation has extremely low sensitivity but high specificity for pathological murmur in latent rheumatic heart disease. Focussed hand-held echocardiography has fair sensitivity but high specificity and diagnostic utility for definite or borderline rheumatic heart disease in asymptomatic patients.

  7. Hand-held tidal breathing nasal nitric oxide measurement--a promising targeted case-finding tool for the diagnosis of primary ciliary dyskinesia

    DEFF Research Database (Denmark)

    Marthin, June Kehlet; Nielsen, Kim Gjerum

    2013-01-01

    BACKGROUND: Nasal nitric oxide (nNO) measurement is an established first line test in the work-up for primary ciliary dyskinesia (PCD). Tidal breathing nNO (TB-nNO) measurements require minimal cooperation and are potentially useful even in young children. Hand-held NO devices are becoming...... increasingly widespread for asthma management. Therefore, we chose to assess whether hand-held TB-nNO measurements reliably discriminate between PCD, and Healthy Subjects (HS) and included Cystic Fibrosis (CF) patients as a disease control group known to have intermediate nNO levels. METHODS: In this cross...... sectional, single centre, single occasion, proof-of-concept study in children and adults with PCD and CF, and in HS we compared feasibility, success rates, discriminatory capacity, repeatability and agreement between a hand-held electrochemical device equipped with a nNO software application sampling...

  8. Survey reveals public open to ban on hand-held cell phone use and texting.

    Science.gov (United States)

    2013-01-01

    A study performed by the Bureau of Transportation Statistics (BTS) reveals that the public is open to a ban on hand-held cell phone use while driving. The study is based on data from 2009s Omnibus Household Survey (OHS), which is administered by B...

  9. Learning Motivation and Adaptive Video Caption Filtering for EFL Learners Using Handheld Devices

    Science.gov (United States)

    Hsu, Ching-Kun

    2015-01-01

    The aim of this study was to provide adaptive assistance to improve the listening comprehension of eleventh grade students. This study developed a video-based language learning system for handheld devices, using three levels of caption filtering adapted to student needs. Elementary level captioning excluded 220 English sight words (see Section 1…

  10. Hand-held spectrophotometer design for textile fabrics

    Science.gov (United States)

    Böcekçi, Veysel Gökhan; Yıldız, Kazım

    2017-09-01

    In this study, a hand-held spectrophotometer was designed by taking advantage of the developments in modern optoelectronic technology. Spectrophotometer devices are used to determine the color information from the optic properties of the materials. As an alternative to a desktop spectrophotometer device we have implemented, it is the first prototype, low cost and portable. The prototype model designed for the textile industry can detect the color tone of any fabric. The prototype model consists of optic sensor, processor, display floors. According to the color applied on the optic sensor, it produces special frequency information on its output at that color value. In Arduino type processor, the frequency information is evaluated by the program we have written and the color tone information between 0-255 ton is decided and displayed on the screen.

  11. Exploring field-of-view non-uniformities produced by a hand-held spectroradiometer

    Directory of Open Access Journals (Sweden)

    Tamir Caras

    2011-01-01

    Full Text Available The shape of a spectroradiometer’s field of view (FOV affects the way spectral measurements are acquired. Knowing this property is a prerequisite for the correct use of the spectrometer. If the substrate is heterogeneous, the ability to accurately know what is being measured depends on knowing the FOV location, shape, spectral and spatial sensitivity. The GER1500 is a hand-held spectrometer with a fixed lens light entry slit and has a laser guide that allows control over the target by positioning the entire unit. In the current study, the FOV of the GER1500 was mapped and analysed. The spectral and spatial non-uniformities of the FOV were examined and were found to be spectrally independent. The relationship between the FOV and the built-in laser guide was tested and found to have a linear displacement dependent on the distance to the target. This allows an accurate prediction of the actual FOV position. A correction method to improve the agreement between the expected and measured reflectance over heterogeneous targets was developed and validated. The methods described are applicable and may be of use with other hand-held spectroradiometers.

  12. 75 FR 43206 - In the Matter of Certain Wireless Communications System Server Software, Wireless Handheld...

    Science.gov (United States)

    2010-07-23

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-706] In the Matter of Certain Wireless Communications System Server Software, Wireless Handheld Devices and Battery Packs: Notice of Commission... United States after importation of certain wireless communications system server software, wireless...

  13. Applying Hand-Held 3D Printing Technology to the Teaching of VSEPR Theory

    Science.gov (United States)

    Dean, Natalie L.; Ewan, Corrina; McIndoe, J. Scott

    2016-01-01

    The use of hand-held 3D printing technology provides a unique and engaging approach to learning VSEPR theory by enabling students to draw three-dimensional depictions of different molecular geometries, giving them an appreciation of the shapes of the building blocks of complex molecular structures. Students are provided with 3D printing pens and…

  14. Rich internet application system for patient-centric healthcare data management using handheld devices.

    Science.gov (United States)

    Constantinescu, L; Pradana, R; Kim, J; Gong, P; Fulham, Michael; Feng, D

    2009-01-01

    Rich Internet Applications (RIAs) are an emerging software platform that blurs the line between web service and native application, and is a powerful tool for handheld device deployment. By democratizing health data management and widening its availability, this software platform has the potential to revolutionize telemedicine, clinical practice, medical education and information distribution, particularly in rural areas, and to make patient-centric medical computing a reality. In this paper, we propose a telemedicine application that leverages the ability of a mobile RIA platform to transcode, organise and present textual and multimedia data, which are sourced from medical database software. We adopted a web-based approach to communicate, in real-time, with an established hospital information system via a custom RIA. The proposed solution allows communication between handheld devices and a hospital information system for media streaming with support for real-time encryption, on any RIA enabled platform. We demonstrate our prototype's ability to securely and rapidly access, without installation requirements, medical data ranging from simple textual records to multi-slice PET-CT images and maximum intensity (MIP) projections.

  15. Elbow joint position sense after neuromuscular training with handheld vibration.

    Science.gov (United States)

    Tripp, Brady L; Faust, Donald; Jacobs, Patrick

    2009-01-01

    Clinicians use neuromuscular control exercises to enhance joint position sense (JPS); however, because standardizing such exercises is difficult, validations of their use are limited. To evaluate the acute effects of a neuromuscular training exercise with a handheld vibrating dumbbell on elbow JPS acuity. Crossover study. University athletic training research laboratory. Thirty-one healthy, college-aged volunteers (16 men, 15 women, age = 23 + or - 3 years, height = 173 + or - 8 cm, mass = 76 + or - 14 kg). We measured and trained elbow JPS using an electromagnetic tracking device that provided auditory and visual biofeedback. For JPS testing, participants held a dumbbell and actively identified the target elbow flexion angle (90 degrees ) using the software-generated biofeedback, followed by 3 repositioning trials without feedback. Each neuromuscular training protocol included 3 exercises during which participants held a 2.55-kg dumbbell vibrating at 15, 5, or 0 Hz and used software-generated biofeedback to locate and maintain the target elbow flexion angle for 15 seconds. We calculated absolute (accuracy) and variable (variability) errors using the differences between target and reproduced angles. Training protocols using 15-Hz vibration enhanced accuracy and decreased variability of elbow JPS (P or = .200). Our results suggest these neuromuscular control exercises, which included low-magnitude, low-frequency handheld vibration, may enhance elbow JPS. Future researchers should examine vibration of various durations and frequencies, should include injured participants and functional multijoint and multiplanar measures, and should examine long-term effects of training protocols on JPS and injury.

  16. A Study of the Use of a Handheld Computer Algebra System in Discrete Mathematics

    Science.gov (United States)

    Powers, Robert A.; Allison, Dean E.; Grassl, Richard M.

    2005-01-01

    This study investigated the impact of the TI-92 handheld Computer Algebra System (CAS) on student achievement in a discrete mathematics course. Specifically, the researchers examined the differences between a CAS section and a control section of discrete mathematics on students' in-class examinations. Additionally, they analysed student approaches…

  17. Comparing handheld and hands-free cell phone usage behaviors while driving.

    Science.gov (United States)

    Soccolich, Susan A; Fitch, Gregory M; Perez, Miguel A; Hanowski, Richard J

    2014-01-01

    The goal of this study was to compare cell phone usage behaviors while driving across 3 types of cell phones: handheld (HH) cell phones, portable hands-free (PHF) cell phones, and integrated hands-free (IHF) cell phones. Naturalistic driving data were used to observe HH, PHF, and IHF usage behaviors in participants' own vehicles without any instructions or manipulations by researchers. In addition to naturalistic driving data, drivers provided their personal cell phone call records. Calls during driving were sampled and observed in naturalistically collected video. Calls were reviewed to identify cell phone type used for, and duration of, cell phone subtasks, non-cell phone secondary tasks, and other use behaviors. Drivers in the study self-identified as HH, PHF, or IHF users if they reported using that cell phone type at least 50% of the time. However, each sampled call was classified as HH, PHF, or IHF if the talking/listening subtask was conducted using that cell phone type, without considering the driver's self-reported group. Drivers with PHF or IHF systems also used HH cell phones (IHF group used HH cell phone in 53.2% of the interactions, PHF group used HH cell phone for 55.5% of interactions). Talking/listening on a PHF phone or an IHF phone was significantly longer than talking/listening on an HH phone (P phone call task for HH phones was significantly longer in duration than the end phone call task for PHF and IHF phones. Of all the non-cell phone-related secondary tasks, eating or drinking was found to occur significantly more often during IHF subtasks (0.58%) than in HH subtasks (0.15%). Drivers observed to reach for their cell phone mostly kept their cell phone in the cup holder (36.3%) or in their seat or lap (29.0% of interactions); however, some observed locations may have required drivers to move out of position. Hands-free cell phone technologies reduce the duration of cell phone visual-manual tasks compared to handheld cell phones. However

  18. Technological characteristics of digital video broadcasting: Handheld standard DVB-H

    Directory of Open Access Journals (Sweden)

    Andreja B. Samčović

    2011-07-01

    Full Text Available This paper gives an overview of the Digital Video Broadcasting - Handheld standard DVB-H, as a part of the DVB Project. This standard is based on the previous standard DVB-T, which was developed for the terrestrial digital television. The ways of DVB-H signal transmission are also described. Development of advanced technology enabled the digital video broadcasting over wireless portable terminals. This paper discusses the key technological features of the DVB-H standard, such as: time slicing, forward error correction, 4K mode and in-depth interleavers.

  19. 75 FR 10502 - In the Matter of Certain Electronic Devices, Including Handheld Wireless Communications Devices...

    Science.gov (United States)

    2010-03-08

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-667; Investigation No. 337-TA-673] In the Matter of Certain Electronic Devices, Including Handheld Wireless Communications Devices; Notice of... Entirety AGENCY: U.S. International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that...

  20. Strength and Pain Threshold Handheld Dynamometry Test Reliability in Patellofemoral Pain.

    Science.gov (United States)

    van der Heijden, R A; Vollebregt, T; Bierma-Zeinstra, S M A; van Middelkoop, M

    2015-12-01

    Patellofemoral pain syndrome (PFPS), characterized by peri- and retropatellar pain, is a common disorder in young, active people. The etiology is unclear; however, quadriceps strength seems to be a contributing factor, and sensitization might play a role. The study purpose is determining the inter-rater reliability of handheld dynamometry to test both quadriceps strength and pressure pain threshold (PPT), a measure for sensitization, in patients with PFPS. This cross-sectional case-control study comprises 3 quadriceps strength and one PPT measurements performed by 2 independent investigators in 22 PFPS patients and 16 matched controls. Inter-rater reliability was analyzed using intraclass correlation coefficients (ICC) and Bland-Altman plots. Inter-rater reliability of quadriceps strength testing was fair to good in PFPS patients (ICC=0.72) and controls (ICC=0.63). Bland-Altman plots showed an increased difference between assessors when average quadriceps strength values exceeded 250 N. Inter-rater reliability of PPT was excellent in patients (ICC=0.79) and fair to good in controls (ICC=0.52). Handheld dynamometry seems to be a reliable method to test both quadriceps strength and PPT in PFPS patients. Inter-rater reliability was higher in PFPS patients compared to control subjects. With regard to quadriceps testing, a higher variance between assessors occurs when quadriceps strength increases. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Detection of pigments of halophilic endoliths from gypsum: Raman portable instrument and European Space Agency's prototype analysis

    Science.gov (United States)

    Culka, Adam; Osterrothová, Kateřina; Hutchinson, Ian; Ingley, Richard; McHugh, Melissa; Oren, Aharon; Edwards, Howell G. M.; Jehlička, Jan

    2014-01-01

    A prototype instrument, under development at the University of Leicester, for the future European Space Agency (ESA) ExoMars mission, was used for the analysis of microbial pigments within a stratified gypsum crust from a hypersaline saltern evaporation pond at Eilat (Israel). Additionally, the same samples were analysed using a miniaturized Raman spectrometer, featuring the same 532 nm excitation. The differences in the position of the specific bands, attributed to carotenoid pigments from different coloured layers, were minor when analysed by the ESA prototype instrument; therefore, making it difficult to distinguish among the different pigments. The portable Delta Nu Advantage instrument allowed for the discrimination of microbial carotenoids from the orange/green and purple layers. The purpose of this study was to complement previous laboratory results with new data and experience with portable or handheld Raman systems, even with a dedicated prototype Raman system for the exploration of Mars. The latter is equipped with an excitation wavelength falling within the carotenoid polyene resonance region. The ESA prototype Raman instrument detected the carotenoid pigments (biomarkers) with ease, although further detailed distinctions among them were not achieved. PMID:25368354

  2. Detection of pigments of halophilic endoliths from gypsum: Raman portable instrument and European Space Agency's prototype analysis.

    Science.gov (United States)

    Culka, Adam; Osterrothová, Kateřina; Hutchinson, Ian; Ingley, Richard; McHugh, Melissa; Oren, Aharon; Edwards, Howell G M; Jehlička, Jan

    2014-12-13

    A prototype instrument, under development at the University of Leicester, for the future European Space Agency (ESA) ExoMars mission, was used for the analysis of microbial pigments within a stratified gypsum crust from a hypersaline saltern evaporation pond at Eilat (Israel). Additionally, the same samples were analysed using a miniaturized Raman spectrometer, featuring the same 532 nm excitation. The differences in the position of the specific bands, attributed to carotenoid pigments from different coloured layers, were minor when analysed by the ESA prototype instrument; therefore, making it difficult to distinguish among the different pigments. The portable Delta Nu Advantage instrument allowed for the discrimination of microbial carotenoids from the orange/green and purple layers. The purpose of this study was to complement previous laboratory results with new data and experience with portable or handheld Raman systems, even with a dedicated prototype Raman system for the exploration of Mars. The latter is equipped with an excitation wavelength falling within the carotenoid polyene resonance region. The ESA prototype Raman instrument detected the carotenoid pigments (biomarkers) with ease, although further detailed distinctions among them were not achieved. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  3. Absorption Related to Hand-Held Devices in Data Mode

    DEFF Research Database (Denmark)

    Andersen, Jørgen Bach; Nielsen, Jesper Ødum; Pedersen, Gert F.

    2016-01-01

    The human body has an influence on the radiation from handheld devices like smartphones, tablets and laptops, part of the energy is absorbed and the spatial distribution of the radiated part is modified. Previous studies of whole body absorp- tion have mainly been numerical or related to talk mode....... In the present paper an experimental study involving four volunteers and three different devices is performed from 0.5 to 3 GHz. The devices are a laptop, a tablet, and a smartphone all held in the lap. The 3D distribution of radiation is measured. Comparing the integrated power in the case of a person present...

  4. A sensitive, handheld vapor sensor based on microcantilevers

    Science.gov (United States)

    Pinnaduwage, L. A.; Hedden, D. L.; Gehl, A.; Boiadjiev, V. I.; Hawk, J. E.; Farahi, R. H.; Thundat, T.; Houser, E. J.; Stepnowski, S.; McGill, R. A.; Deel, L.; Lareau, R. T.

    2004-11-01

    We report the development of a handheld sensor based on piezoresistive microcantilevers that does not depend on optical detection, yet has high detection sensitivity. The sensor is able to detect vapors from the plastic explosives pentaerythritol tetranitrate and hexahydro-1,3,5-triazine at levels below 10 parts per trillion within few seconds of exposure under ambient conditions. A differential measurement technique has yielded a rugged sensor that is unaffected by vibration and is able to function as a "sniffer." The microelectromechanical system sensor design allows for the incorporation of hundreds of microcantilevers with suitable coatings in order to achieve sufficient selectivity in the future, and thus could provide an inexpensive, unique platform for the detection of chemical, biological, and explosive materials.

  5. A handheld optical device for skin profile measurement

    Science.gov (United States)

    Sun, Jiuai; Liu, Xiaojin

    2018-04-01

    This paper describes a portable optical scanning device designed for skin surface measurement on both colour and 3D geometry through a relative easy and cost effective multiple light source photometric stereo method. The validation of colour recovered had been verified through its application on skin lesion segmentation in our early work. This paper focuses on the reconstructed topographic data which are subject to further evaluation and advancement. The evaluation work takes the skin in vitro as an application scenario and compares the experimental result to that obtained by using a commercial product. The experiments show that this handheld device can measure the skin profile significantly closer to that of the ground truth and have the additional function of skin colour recovery.

  6. 4. The Feldenkrais Method in the Puppeteer’s Training from the Perspective of Nicolas Gousseff’s Handheld Puppets Workshops

    Directory of Open Access Journals (Sweden)

    Ciofu Anca-Mihaela

    2018-03-01

    Full Text Available Although the Feldenkrais method is quite well-known and used in relation to dance, music, and acting, it is rather uncommon to associate it with animation theatre. The puppeteer’s art is a profession that requires motor skills and sustained physical effort, which demands that the animating actor has an extended consciousness of oneself and of the space. Therefore, the Feldenkrais method can be a useful instrument in the puppeteer’s education and training, as the placing of the body in a relaxed stance, one which helps in the management of pain and effort, facilitates the conscious and creative learning of animation techniques, with an emphasis on the coordination and fluidity of movement. These are learning principles of the art of animation that are successfully used by Nicolas Gousseff, an artist that was formed at ESNAM (École Supérieure Nationale des Arts de la Marionnette de la Charleville-Mézières, and who has specialized in handheld puppets and using the actor’s body as a performative space for this type of animation.

  7. Contact lens assisted imaging with integrated flexible handheld probe for glaucoma diagnosis

    Science.gov (United States)

    Hong, Xun Jie Jeesmond; V. K., Shinoj; Murukeshan, V. M.; Baskaran, M.; Aung, Tin

    2017-06-01

    Angle closure glaucoma accounts for majority of the bilateral blindness in Asian countries such as Singapore, China, and India. Abnormalities in the optic nerve and aqueous outflow system are the most indicative clinical hallmarks for glaucoma of this clinical subtype. Traditional photographic imaging techniques to assess the drainage angle are contact based, and may expose patients to risk of corneal abrasion and infections. In addition, these procedures require the use of viscous ophthalmic gels as coupling medium to overcome the phenomenon of total internal reflection at the tear-air interface. In this paper, we propose an integrated flexible handheld probe consisting of a micro color CCD video camera and white light LEDs. The handheld probe is able to capture images of the fundus and opposite iridocorneal angle when placed at the central cornea or limbus respectively. Here, we propose the use of hydrogel contact lens as an index matching medium and better protective barrier, as an alternative to conventional ophthalmic gels. The proposed imaging system and methodology has been successfully tested on porcine eye samples, ex vivo. With its high repeatability, reproducibility, and a good safety profile, it is believed that the proposed imaging system and methodology will complement existing imaging modalities in the diagnosis and management of glaucoma.

  8. Use of handheld X-ray fluorescence spectrometry units for identification of arsenic in treated wood

    Energy Technology Data Exchange (ETDEWEB)

    Block, Colleen N. [University of Miami, Department of Civil, Architectural, and Environmental Engineering, P.O. Box 248294, McArthur Building, Coral Gables, FL 33124-0630 (United States); Shibata, Tomoyuki [University of Miami, Department of Civil, Architectural, and Environmental Engineering, P.O. Box 248294, McArthur Building, Coral Gables, FL 33124-0630 (United States); Solo-Gabriele, Helena M. [University of Miami, Department of Civil, Architectural, and Environmental Engineering, P.O. Box 248294, McArthur Building, Coral Gables, FL 33124-0630 (United States)]. E-mail: hmsolo@miami.edu; Townsend, Timothy G. [University of Florida, Department of Environmental Engineering Sciences, Gainesville, FL 32611-6450 (United States)

    2007-07-15

    The objective of this study was to evaluate the performance of handheld XRF analyzers on wood that has been treated with a preservative containing arsenic. Experiments were designed to evaluate precision, detection limit, effective depth of analysis, and accuracy of the XRF arsenic readings. Results showed that the precision of the XRF improved with increased sample concentration and longer analysis times. Reported detection limits decreased with longer analysis times to values of less than 1 mg/kg or 18 mg/kg, depending on the model used. The effective depth of analysis was within the top 1.2 cm and 2.0 cm of sample for wood containing natural gradients of chemical preservative and concentration extremes, respectively. XRF results were found to be 1.5-2.3 times higher than measurements from traditional laboratory analysis. Equations can be developed to convert XRF values to results which are consistent with traditional laboratory testing. - Handheld XRF analyzers provided quantitative results for the amount of arsenic within preservative-treated wood.

  9. Font size and viewing distance of handheld smart phones.

    Science.gov (United States)

    Bababekova, Yuliya; Rosenfield, Mark; Hue, Jennifer E; Huang, Rae R

    2011-07-01

    The use of handheld smart phones for written communication is becoming ubiquitous in modern society. The relatively small screens found in these devices may necessitate close working distances and small text sizes, which can increase the demands placed on accommodation and vergence. Font size and viewing distance were measured while subjects used handheld electronic devices in two separate trials. In the first study (n=129), subjects were asked to show a typical text message on their own personal phone and to hold the device "as if they were about to read a text message." A second trial was conducted in a similar manner except subjects (n=100) were asked to view a specific web page from the internet. For text messages and internet viewing, the mean font size was 1.1 M (range, 0.7 to 2.1 M) and 0.8 M (range, 0.3 to 1.4 M), respectively. The mean working distance for text messages and internet viewing was 36.2 cm (range, 17.5 to 58.0 cm) and 32.2 cm (range, 19 to 60 cm), respectively. The mean font size for both conditions was comparable with newspaper print, although some subjects viewed text that was considerably smaller. However, the mean working distances were closer than the typical near working distance of 40 cm for adults when viewing hardcopy text. These close distances place increased demands on both accommodation and vergence, which could exacerbate symptoms. Practitioners need to consider the closer distances adopted while viewing material on smart phones when examining patients and prescribing refractive corrections for use at near, as well as when treating patients presenting with asthenopia associated with nearwork. Copyright © 2011 American Academy of Optometry

  10. Using handheld devices for real-time wireless teleconsultation.

    Science.gov (United States)

    Banitsas, K A; Georgiadis, P; Tachakra, S; Cavouras, D

    2004-01-01

    Recent advances in the hardware of handheld devices, opened up the way for newer applications in the healthcare sector, and more specifically, in the teleconsultation field. Out of these devices, this paper focuses on the services that personal digital assistants and smartphones can provide to improve the speed, quality and ease of delivering a medical opinion from a distance and laying the ground for an all-wireless hospital. In that manner, PDAs were used to wirelessly support the viewing of digital imaging and communication in medicine (DICOM) images and to allow for mobile videoconferencing while within the hospital. Smartphones were also used to carry still images, multiframes and live video outside the hospital. Both of these applications aimed at increasing the mobility of the consultant while improving the healthcare service.

  11. Gamma-ray detectors for intelligent, hand-held radiation monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1983-01-01

    Small radiation detectors based on HgI 2 , bismuth germanate (BGO), plastic, or NaI(Tl) detector materials were evaluated for use in small, lighweight radiation monitors. The two denser materials, HgI 2 and BGO, had poor resolution at low-energy and thus performed less well than NaI(Tl) in detecting low-energy gamma rays from bare, enriched uranium. The plastic scintillator, a Compton recoil detector, also performed less well at low gamma-ray energy. Two small NaI(Tl) detectors were suitable for detecting bare uranium and sheilded plutonium. One became part of a new lightweight hand-held monitor and the other found uses as a pole-mounted detector for monitoring hard-to-reach locations

  12. Spectral domain, common path OCT in a handheld PIC based system

    Science.gov (United States)

    Leinse, Arne; Wevers, Lennart; Marchenko, Denys; Dekker, Ronald; Heideman, René G.; Ruis, Roosje M.; Faber, Dirk J.; van Leeuwen, Ton G.; Kim, Keun Bae; Kim, Kyungmin

    2018-02-01

    Optical Coherence Tomography (OCT) has made it into the clinic in the last decade with systems based on bulk optical components. The next disruptive step will be the introduction of handheld OCT systems. Photonic Integrated Circuit (PIC) technology is the key enabler for this further miniaturization. PIC technology allows signal processing on a stable platform and the implementation of a common path interferometer in that same platform creates a robust fully integrated OCT system with a flexible fiber probe. In this work the first PIC based handheld and integrated common path based spectral domain OCT system is described and demonstrated. The spectrometer in the system is based on an Arrayed Waveguide Grating (AWG) and fully integrated with the CCD and a fiber probe into a system operating at 850 nm. The AWG on the PIC creates a 512 channel spectrometer with a resolution of 0.22 nm enabling a high speed analysis of the full A-scan. The silicon nitride based proprietary waveguide technology (TriPleXTM) enables low loss complex photonic structures from the visible (405 nm) to IR (2350 nm) range, making it a unique candidate for OCT applications. Broadband AWG operation from visible to 1700 nm has been shown in the platform and Photonic Design Kits (PDK) are available enabling custom made designs in a system level design environment. This allows a low threshold entry for designing new (OCT) designs for a broad wavelength range.

  13. The Xsense project: The application of an intelligent sensor array for high sensitivity handheld explosives detectors

    DEFF Research Database (Denmark)

    Kostesha, Natalie; Schmidt, Michael Stenbæk; Bosco, Filippo

    2011-01-01

    Multiple independent sensors are used in security and military applications in order to increase sensitivity, selectivity and data reliability. The Xsense project has been initiated at the Technical University of Denmark in collaboration with a number of partners in an effort to produce a handheld...

  14. Introducing Handheld Computing for Interactive Medical Education

    Directory of Open Access Journals (Sweden)

    Joseph Finkelstein

    2005-04-01

    Full Text Available The goals of this project were: (1 development of an interactive multimedia medical education tool (CO-ED utilizing modern features of handheld computing (PDA and major constructs of adult learning theories, and (2 pilot testing of the computer-assisted education in residents and clinicians. Comparison of the knowledge scores using paired t-test demonstrated statistically significant increase in subject knowledge (p<0.01 after using CO-ED. Attitudinal surveys were analyzed by total score (TS calculation represented as a percentage of a maximal possible score. The mean TS was 74.5±7.1%. None of the subjects (N=10 had TS less than 65% and in half of the subjects (N=5 TS was higher than 75%. Analysis of the semi-structured in-depth interviews showed strong support of the study subjects in using PDA as an educational tool, and high acceptance of CO-ED user interface. We concluded that PDA have a significant potential as a tool for clinician education.

  15. A new approach for the screening of carotid lesions: a 'fast-track' method with the use of new generation hand-held ultrasound devices.

    Science.gov (United States)

    Aboyans, V; Lacroix, P; Jeannicot, A; Guilloux, J; Bertin, F; Laskar, M

    2004-09-01

    We assessed the usefulness of fast-track neck sonography with a new-generation hand-held ultrasound scanner in the detection of > or =60% carotid stenosis. Patients with a past history of atherosclerotic disease or presence of risk factors were enrolled. All had fast-track carotid screening with a hand-held ultrasound scanner. Initial assessment was performed with our quick imaging protocol. A second examiner performed a conventional complete carotid duplex as gold-standard. We enrolled 197 consecutive patients with a mean age of 67 years (range 35-94). A carotid stenosis >60% was detected in 13 cases (6%). The sensitivity, specificity, positive and negative predictive value of fast-track sonography was 100%, 64%, 17% and 100%, respectively. Concomitant power Doppler imaging during the fast-track method did not improve accuracy. The use of a fast-track method with a hand-held ultrasound device can reduce the number of unnecessary carotid Duplex and enhance the screening efficiency without missing significant carotid stenoses.

  16. A Mobile Mixed-Reality Environment for Children's Storytelling Using a Handheld Projector and a Robot

    Science.gov (United States)

    Sugimoto, Masanori

    2011-01-01

    This paper describes a system called GENTORO that uses a robot and a handheld projector for supporting children's storytelling activities. GENTORO differs from many existing systems in that children can make a robot play their own story in a physical space augmented by mixed-reality technologies. Pilot studies have been conducted to clarify the…

  17. Handheld Micromanipulator for Robot-Assisted Stapes Footplate Surgery

    Science.gov (United States)

    Grande, Gonzalo Montes; Knisely, Anna J.; Becker, Brian C.; Yang, Sungwook; Hirsch, Barry E.; Riviere, Cameron N.

    2012-01-01

    Stapes footplate surgery is complex and delicate. This surgery is carried out in the middle ear to improve hearing. High accuracy is required to avoid critical tissues and structures near the surgical worksite. By suppressing the surgeon’s tremor during the operation, accuracy can be improved. In this paper, a fully handheld active micromanipulator known as Micron is evaluated for its feasibility for this delicate operation. An ergonomic handle, a custom tip, and a brace attachment were designed for stapes footplate surgery and tested in a fenestration task through a fixed speculum. Accuracy was measured during simulated surgery in two different scenarios: Micron off (unaided) and Micron on (aided), both with image guidance. Preliminary results show that Micron significantly reduces the mean position error and the mean duration of time spent in specified dangerous zones. PMID:23366167

  18. Correlation and Agreement of Handheld Spirometry with Laboratory Spirometry in Allogeneic Hematopoietic Cell Transplant Recipients.

    Science.gov (United States)

    Cheng, Guang-Shing; Campbell, Angela P; Xie, Hu; Stednick, Zach; Callais, Cheryl; Leisenring, Wendy M; Englund, Janet A; Chien, Jason W; Boeckh, Michael

    2016-05-01

    Early detection of subclinical lung function decline may help identify allogeneic hematopoietic cell transplant (HCT) recipients who are at increased risk for late noninfectious pulmonary complications, including bronchiolitis obliterans syndrome. We evaluated the use of handheld spirometry in this population. Allogeneic HCT recipients enrolled in a single-center observational trial performed weekly spirometry with a handheld spirometer for 1 year after transplantation. Participants performed pulmonary function tests in an outpatient laboratory setting at 3 time points: before transplantation, at day 80 after transplantation, and at 1 year after transplantation. Correlation between the 2 methods was assessed by Pearson and Spearman correlations; agreement was assessed using Bland-Altman plots. A total of 437 subjects had evaluable pulmonary function tests. Correlation for forced expiratory volume in 1 second (FEV1) was r = .954 (P spirometry correlated well with laboratory spirometry after allogeneic HCT and may be useful for self-monitoring of patients for early identification of airflow obstruction. Copyright © 2016 American Society for Blood and Marrow Transplantation. All rights reserved.

  19. Performance of handheld electrocardiogram devices to detect atrial fibrillation in a cardiology and geriatric ward setting.

    Science.gov (United States)

    Desteghe, Lien; Raymaekers, Zina; Lutin, Mark; Vijgen, Johan; Dilling-Boer, Dagmara; Koopman, Pieter; Schurmans, Joris; Vanduynhoven, Philippe; Dendale, Paul; Heidbuchel, Hein

    2017-01-01

    To determine the usability, accuracy, and cost-effectiveness of two handheld single-lead electrocardiogram (ECG) devices for atrial fibrillation (AF) screening in a hospital population with an increased risk for AF. Hospitalized patients (n = 445) at cardiological or geriatric wards were screened for AF by two handheld ECG devices (MyDiagnostick and AliveCor). The performance of the automated algorithm of each device was evaluated against a full 12-lead or 6-lead ECG recording. All ECGs and monitor tracings were also independently reviewed in a blinded fashion by two electrophysiologists. Time investments by nurses and physicians were tracked and used to estimate cost-effectiveness of different screening strategies. Handheld recordings were not possible in 7 and 21.4% of cardiology and geriatric patients, respectively, because they were not able to hold the devices properly. Even after the exclusion of patients with an implanted device, sensitivity and specificity of the automated algorithms were suboptimal (Cardiology: 81.8 and 94.2%, respectively, for MyDiagnostick; 54.5 and 97.5%, respectively, for AliveCor; Geriatrics: 89.5 and 95.7%, respectively, for MyDiagnostick; 78.9 and 97.9%, respectively, for AliveCor). A scenario based on automated AliveCor evaluation in patients without AF history and without an implanted device proved to be the most cost-effective method, with a provider cost to identify one new AF patient of €193 and €82 at cardiology and geriatrics, respectively. The cost to detect one preventable stroke per year would be €7535 and €1916, respectively (based on average CHA 2 DS 2 -VASc of 3.9 ± 2.0 and 5.0 ± 1.5, respectively). Manual interpretation increases sensitivity, but decreases specificity, doubling the cost per detected patient, but remains cheaper than sole 12-lead ECG screening. Using AliveCor or MyDiagnostick handheld recorders requires a structured screening strategy to be effective and cost-effective in a hospital setting

  20. 76 FR 22918 - In the Matter of Certain Handheld Electronic Computing Devices, Related Software, and Components...

    Science.gov (United States)

    2011-04-25

    ... INTERNATIONAL TRADE COMMISSION [Inv. No. 337-TA-769] In the Matter of Certain Handheld Electronic.... International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that a complaint was filed with the U.S. International Trade Commission on March 21, 2011, under section 337 of the Tariff Act of 1930...

  1. Comparative Geometrical Investigations of Hand-Held Scanning Systems

    Science.gov (United States)

    Kersten, T. P.; Przybilla, H.-J.; Lindstaedt, M.; Tschirschwitz, F.; Misgaiski-Hass, M.

    2016-06-01

    An increasing number of hand-held scanning systems by different manufacturers are becoming available on the market. However, their geometrical performance is little-known to many users. Therefore the Laboratory for Photogrammetry & Laser Scanning of the HafenCity University Hamburg has carried out geometrical accuracy tests with the following systems in co-operation with the Bochum University of Applied Sciences (Laboratory for Photogrammetry) as well as the Humboldt University in Berlin (Institute for Computer Science): DOTProduct DPI-7, Artec Spider, Mantis Vision F5 SR, Kinect v1 + v2, Structure Sensor and Google's Project Tango. In the framework of these comparative investigations geometrically stable reference bodies were used. The appropriate reference data were acquired by measurement with two structured light projection systems (AICON smartSCAN and GOM ATOS I 2M). The comprehensive test results of the different test scenarios are presented and critically discussed in this contribution.

  2. Development of a miRNA surface-enhanced Raman scattering assay using benchtop and handheld Raman systems

    Science.gov (United States)

    Schechinger, Monika; Marks, Haley; Locke, Andrea; Choudhury, Mahua; Cote, Gerard

    2018-01-01

    DNA-functionalized nanoparticles, when paired with surface-enhanced Raman spectroscopy (SERS), can rapidly detect microRNA. However, widespread use of this approach is hindered by drawbacks associated with large and expensive benchtop Raman microscopes. MicroRNA-17 (miRNA-17) has emerged as a potential epigenetic indicator of preeclampsia, a condition that occurs during pregnancy. Biomarker detection using an SERS point-of-care device could enable prompt diagnosis and prevention as early as the first trimester. Recently, strides have been made in developing portable Raman systems for field applications. An SERS assay for miRNA-17 was assessed and translated from traditional benchtop Raman microscopes to a handheld system. Three different photoactive molecules were compared as potential Raman reporter molecules: a chromophore, malachite green isothiocyanate (MGITC), a fluorophore, tetramethylrhodamine isothiocyanate, and a polarizable small molecule 5,5-dithio-bis-(2-nitrobenzoic acid) (DTNB). For the benchtop Raman microscope, the DTNB-labeled assay yielded the greatest sensitivity under 532-nm laser excitation, but the MGITC-labeled assay prevailed at 785 nm. Conversely, DTNB was preferable for the miniaturized 785-nm Raman system. This comparison showed significant SERS enhancement variation in response to 1-nM miRNA-17, implying that the sensitivity of the assay may be more heavily dependent on the excitation wavelength, instrumentation, and Raman reporter chosen than on the plasmonic coupling from DNA/miRNA-mediated nanoparticle assemblies.

  3. Intra-operative ultrasound hand-held strain imaging for the visualization of ablations produced in the liver with a toroidal HIFU transducer: first in vivo results

    Energy Technology Data Exchange (ETDEWEB)

    Chenot, J; Melodelima, D; N' Djin, W A; Souchon, Remi; Rivoire, M; Chapelon, J Y, E-mail: jeremy.chenot@inserm.f [Inserm, U556, Lyon, F-69003 (France)

    2010-06-07

    The use of hand-held ultrasound strain imaging for the intra-operative real-time visualization of HIFU (high-intensity focused ultrasound) ablations produced in the liver by a toroidal transducer was investigated. A linear 12 MHz ultrasound imaging probe was used to obtain radiofrequency signals. Using a fast cross-correlation algorithm, strain images were calculated and displayed at 60 frames s{sup -1}, allowing the use of hand-held strain imaging intra-operatively. Fourteen HIFU lesions were produced in four pigs. Intra-operative strain imaging of HIFU ablations in the liver was feasible owing to the high frame rate. The correlation between dimensions measured on gross pathology and dimensions measured on B-mode images and on strain images were R = 0.72 and R = 0.94 respectively. The contrast between ablated and non-ablated tissue was significantly higher (p < 0.05) in the strain images (22 dB) than in the B-mode images (9 dB). Strain images allowed equivalent or improved definition of ablated regions when compared with B-mode images. Real-time intra-operative hand-held strain imaging seems to be a promising complement to conventional B-mode imaging for the guidance of HIFU ablations produced in the liver during an open procedure. These results support that hand-held strain imaging outperforms conventional B-mode ultrasound and could potentially be used for the assessment of thermal therapies.

  4. An Adaptive Geometry Game for Handheld Devices

    Directory of Open Access Journals (Sweden)

    Harri Ketamo

    2003-01-01

    Full Text Available The development of adaptive learning systems is only in the very beginning. In fact, the concept of adaptive learning systems range from different user interfaces to behaviour adaptive systems as well as from the place and time independent systems to terminal independent systems. When approaching the concept of adaptive learning materials, we must first have conceptual models of the behaviour of different learners within digital environments.The aim of this study was to develop a geometry learning game that adapts to user’s behaviour. The learners in this study were six years old Finnish pre-school pupils. The adaptive system was very limited and the observed behaviour was defined as very simple. However, the software developed achieves good learning results among the tested pupils. The study shows that the learning effect is very promising with this kind of handheld platform and simple adaptation system. This study gives good visions of what can be achieved with more complex behaviour adaptive systems in the field of eLearning.

  5. Extensional rheometry with a handheld mobile device

    Science.gov (United States)

    Marshall, Kristin A.; Liedtke, Aleesha M.; Todt, Anika H.; Walker, Travis W.

    2017-06-01

    The on-site characterization of complex fluids is important for a number of academic and industrial applications. Consequently, a need exists to develop portable rheometers that can provide in the field diagnostics and serve as tools for rapid quality assurance. With the advancement of smartphone technology and the widespread global ownership of smart devices, mobile applications are attractive as platforms for rheological characterization. The present work investigates the use of a smartphone device for the extensional characterization of a series of Boger fluids composed of glycerol/water and poly(ethylene oxide), taking advantage of the increasing high-speed video capabilities (currently up to 240 Hz capture rate at 720p) of smartphone cameras. We report a noticeable difference in the characterization of samples with slight variations in polymer concentration and discuss current device limitations. Potential benefits of a handheld extensional rheometer include its use as a point-of-care diagnostic tool, especially in developing communities, as well as a simple and inexpensive tool for assessing product quality in industry.

  6. Use of a handheld, battery-operated chemistry analyzer for evaluation of heat-related symptoms in the backcountry of Grand Canyon National Park: a brief report.

    Science.gov (United States)

    Backer, H D; Collins, S

    1999-04-01

    To test the feasibility of using handheld, battery-operated chemical analyzers by EMS personnel in a wilderness environment to aid in the diagnosis and management of heat illness. During the summer of 1996, 3 portable clinical analyzers (i-STAT Corp, Princeton, NJ) were kept at different locations along the main hiking trail into the Grand Canyon. An operational protocol was designed for field use, and Park Service EMS personnel used the instruments at their discretion, primarily to determine serum sodium concentration and identify cases of hyponatremia. Data were collected on all EMS encounters. This study reviews our experience with the instruments. The i-STAT analyzer was used for 64 patients in the backcountry; of these uses, at least 22 were in the field and the remainder in backcountry ranger stations. Eight error messages were recorded in 6 patients. Subsequently, all but 1 had a successful determination. Among patients evacuated for further evaluation and care, serum sodium values were highly consistent with later analysis using standard laboratory equipment. The instrument was used in 31 (48%) of 64 of patients evaluated and released for self-treatment and self-evacuation, and 31 (36%) of 87 of patients evacuated by EMS personnel from the canyon. Nine cases of hyponatremia were confirmed in the field, allowing appropriate intervention. Portable clinical analyzers can reliably be used in a hot wilderness environment. In our application, it allowed identification of exercise-associated hyponatremia, an important cause of serious heat illness during endurance exercise in a hot environment. The results helped make treatment and disposition decisions.

  7. Comparison of non-invasive tear film stability measurement techniques.

    Science.gov (United States)

    Wang, Michael Tm; Murphy, Paul J; Blades, Kenneth J; Craig, Jennifer P

    2018-01-01

    Measurement of tear film stability is commonly used to give an indication of tear film quality but a number of non-invasive techniques exists within the clinical setting. This study sought to compare three non-invasive tear film stability measurement techniques: instrument-mounted wide-field white light clinical interferometry, instrument-mounted keratoscopy and hand-held keratoscopy. Twenty-two subjects were recruited in a prospective, randomised, masked, cross-over study. Tear film break-up or thinning time was measured non-invasively by independent experienced examiners, with each of the three devices, in a randomised order, within an hour. Significant correlation was observed between instrument-mounted interferometric and keratoscopic measurements (p 0.05). Tear film stability values obtained from the hand-held device were significantly shorter and demonstrated narrower spread than the other two instruments (all p 0.05). Good clinical agreement exists between the instrument-mounted interferometric and keratoscopic measurements but not between the hand-held device and either of the instrument-mounted techniques. The results highlight the importance of specifying the instrument employed to record non-invasive tear film stability. © 2017 Optometry Australia.

  8. Developing a compact multiple laser diode combiner with a single fiber stub output for handheld IoT devices

    Science.gov (United States)

    Lee, Minseok; June, Seunghyeok; Kim, Sehwan

    2018-01-01

    Many biomedical applications require an efficient combination and localization of multiple discrete light sources ( e.g., fluorescence and absorbance imaging). We present a compact 6 channel combiner that couples the output of independent solid-state light sources into a single 400-μm-diameter fiber stub for handheld Internet of Things (IoT) devices. We demonstrate average coupling efficiencies > 80% for each of the 6 laser diodes installed into the prototype. The design supports the use of continuous wave and intensity-modulated laser diodes. This fiber-stub-type beam combiner could be used to construct custom multi-wavelength sources for tissue oximeters, microscopes and molecular imaging technologies. In order to validate its suitability, we applied the developed fiber-stub-type beam combiner to a multi-wavelength light source for a handheld IoT device and demonstrated its feasibility for smart healthcare through a tumor-mimicking silicon phantom.

  9. Portable (handheld) clinical device for quantitative spectroscopy of skin, utilizing spatial frequency domain reflectance techniques

    Science.gov (United States)

    Saager, Rolf B.; Dang, An N.; Huang, Samantha S.; Kelly, Kristen M.; Durkin, Anthony J.

    2017-09-01

    Spatial Frequency Domain Spectroscopy (SFDS) is a technique for quantifying in-vivo tissue optical properties. SFDS employs structured light patterns that are projected onto tissues using a spatial light modulator, such as a digital micromirror device. In combination with appropriate models of light propagation, this technique can be used to quantify tissue optical properties (absorption, μa, and scattering, μs', coefficients) and chromophore concentrations. Here we present a handheld implementation of an SFDS device that employs line (one dimensional) imaging. This instrument can measure 1088 spatial locations that span a 3 cm line as opposed to our original benchtop SFDS system that only collects a single 1 mm diameter spot. This imager, however, retains the spectral resolution (˜1 nm) and range (450-1000 nm) of our original benchtop SFDS device. In the context of homogeneous turbid media, we demonstrate that this new system matches the spectral response of our original system to within 1% across a typical range of spatial frequencies (0-0.35 mm-1). With the new form factor, the device has tremendously improved mobility and portability, allowing for greater ease of use in a clinical setting. A smaller size also enables access to different tissue locations, which increases the flexibility of the device. The design of this portable system not only enables SFDS to be used in clinical settings but also enables visualization of properties of layered tissues such as skin.

  10. Precise intraoperative location of gastrointestinal bleeding with a hand-held counter. Work in progress

    International Nuclear Information System (INIS)

    Williamson, M.R.; Boyd, C.M.; McGuire, E.L.

    1986-01-01

    The nuclear medicine bleeding scan is frequently insufficient to locate sites of bleeding precisely, in spite of its great sensitivity. A small, hand-held Geiger-Mueller counter, placed directly on exposed intestine in the operating room, enables precise location of the probable bleeding site. In three patients, the technique allowed a minimal amount of intestine to be resected, distinguished between large- and small-intestinal hemorrhage, and eliminated other foci as sites of bleeding.A

  11. COMPARATIVE GEOMETRICAL INVESTIGATIONS OF HAND-HELD SCANNING SYSTEMS

    Directory of Open Access Journals (Sweden)

    T. P. Kersten

    2016-06-01

    Full Text Available An increasing number of hand-held scanning systems by different manufacturers are becoming available on the market. However, their geometrical performance is little-known to many users. Therefore the Laboratory for Photogrammetry & Laser Scanning of the HafenCity University Hamburg has carried out geometrical accuracy tests with the following systems in co-operation with the Bochum University of Applied Sciences (Laboratory for Photogrammetry as well as the Humboldt University in Berlin (Institute for Computer Science: DOTProduct DPI-7, Artec Spider, Mantis Vision F5 SR, Kinect v1 + v2, Structure Sensor and Google’s Project Tango. In the framework of these comparative investigations geometrically stable reference bodies were used. The appropriate reference data were acquired by measurement with two structured light projection systems (AICON smartSCAN and GOM ATOS I 2M. The comprehensive test results of the different test scenarios are presented and critically discussed in this contribution.

  12. Hand-held optical fuel pin scanner

    International Nuclear Information System (INIS)

    Kirchner, T.L.; Powers, H.G.

    1987-01-01

    A portable, hand-held apparatus is described for optically scanning indicia imprinted about a planar end face of an article having an outer wall surface, the apparatus comprising: a supporting frame; light detector means fixed to the frame for digitizing light patterns directed thereto; indexing means on the frame for engaging the planar end face and locating the end face in a preselected focal plane on the frame. The indexing means has an inner wall surface complementary to the article wall surface for disposition thereabout and terminates in an end portion beyond the planar end face. The inner wall surface has a radially inwardly extending shoulder spaced from the end portion and engageable with the planar end face; light means directed onto the preselected focal plane; optical means mounted on the frame about a central axis, the optical means being optically interposed between the indexing means and the light detector means for directing reflected light from the preselected focal plane to the light detector means and including a dove prism centrally aligned along the central axis; and means for selectively rotating the dove prism relative to the frame about the central axis to thereby rotate the image from the focal plane as transmitted to the light detector means

  13. Hip- and knee-strength assessments using a hand-held dynamometer with external belt-fixation are inter-tester reliable

    DEFF Research Database (Denmark)

    Thorborg, Kristian; Bandholm, Thomas; Hölmich, Per

    2013-01-01

    PURPOSE: In football, ice-hockey, and track and field, injuries have been predicted, and hip- and knee-strength deficits quantified using hand-held dynamometry (HHD). However, systematic bias exists when testers of different sex and strength perform the measurements. Belt-fixation of the dynamome...

  14. Visual Search and Target Cueing: A Comparison of Head-Mounted Versus Hand-Held Displays on the Allocation of Visual Attention

    National Research Council Canada - National Science Library

    Yeh, Michelle; Wickens, Christopher D

    1998-01-01

    We conducted a study to examine the effects of target cueing and conformality with a hand-held or head-mounted display to determine their effects on visual search tasks requiring focused and divided attention...

  15. Feasibility of using a handheld electronic device for the collection of patient reported outcomes data from children.

    Science.gov (United States)

    Vinney, Lisa A; Grade, John D; Connor, Nadine P

    2012-01-01

    The manner in which a communication disorder affects health-related quality of life (QOL) in children is not known. Unfortunately, collection of quality of life data via traditional paper measures is labor intensive and has several other limitations, which hinder the investigation of pediatric quality of life in children. Currently, there is not sufficient research regarding the use of electronic devices to collect pediatric patient reported outcomes in order to address such limitations. Thus, we used a cross-over design to compare responses to a pediatric health quality of life instrument (PedsQL 4.0) delivered using a handheld electronic device to those from a traditional paper form. Respondents were children with (n=9) and without (n=10) a speech or voice disorder. For paper versus the electronic format, we examined time to completion, number of incomplete or inaccurate question responses, intra-rater reliability, ease of use, and child and parent preference. There were no significant differences between children's scores, time to complete the measure, or ratings related to ease of answering questions. The percentage of children who made answering errors or omissions with paper and pencil was significantly greater than the percentage of children who made such errors using the device. This preliminary study demonstrated that use of an electronic device to collect QOL or patient-reported outcomes (PRO) data from children is more efficient than and just as feasible, reliable, and acceptable as using paper forms. The development of hardware and software applications for the collection of QOL and/or PRO data in children with speech disorders is likely warranted. The reader will be able to understand: (1) The potential benefits of using electronic data capture via handheld devices for collecting pediatric patient reported outcomes; (2) The Pediatric Quality of Life Inventory 4.0 is a measure of the perception of general health quality that has distinguished between

  16. Hand-held optical sensor using denatured antibody coated electro-active polymer for ultra-trace detection of copper in blood serum and environmental samples.

    Science.gov (United States)

    Chandra, Sutapa; Dhawangale, Arvind; Mukherji, Soumyo

    2018-07-01

    An optimum copper concentration in environment is highly desired for all forms of life. We have developed an ultrasensitive copper sensor which functions from femto to micro molar concentration accurately (R 2 = 0.98). The sensor is based on denatured antibody immunoglobulin G (IgG), immobilized on polyaniline (PAni) which in turn is the coating on the core of an optical fiber. The sensing relies on changes in evanescent wave absorbance in the presence of the analyte. The sensor showed excellent selectivity towards Cu (II) ions over all other metal ions. The sensor was tested with lake and marine water samples to determine unknown concentrations of copper ions and the recovery results were within 90-115%, indicating reasonable accuracy. We further integrated the fiber-optic sensor with a miniaturized hand-held instrumentation platform to develop an accurate and field deployable device which can broadly be applicable to determine Cu (II) concentration in a wide range of systems - natural water bodies, soil as well as blood serum. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Handheld and automated ultrasonic spray deposition of conductive PEDOT:PSS films and their application in AC EL devices

    NARCIS (Netherlands)

    Ely, Fernando; Matsumoto, Agatha; Zoetebier, Bram; Peressinotto, Valdirene S.; Hirata, Marcelo Kioshi; de Sousa, Douglas A.; Maciel, Rubens

    2014-01-01

    In this contribution we explore the spray deposition technique to achieve smooth films based on the conductive polymer PEDOT:PSS. Two different spray systems were used and compared namely: (a) handheld airbrush and (b) automated ultrasonic spray system. For each system a number of parameters were

  18. Performance Investigation of a Handheld 3d Scanner to Define Good Practices for Small Artefact 3d Modeling

    Science.gov (United States)

    Lachat, E.; Landes, T.; Grussenmeyer, P.

    2017-08-01

    Handheld 3D scanners can be used to complete large scale models with the acquisition of occluded areas or small artefacts. This may be of interest for digitization projects in the field of Cultural Heritage, where detailed areas may require a specific treatment. Such sensors present the advantage of being easily portable in the field, and easily usable even without particular knowledge. In this paper, the Freestyle3D handheld scanner launched on the market in 2015 by FARO is investigated. Different experiments are described, covering various topics such as the influence of range or color on the measurements, but also the precision achieved for geometrical primitive digitization. These laboratory experiments are completed by acquisitions performed on engraved and sculpted stone blocks. This practical case study is useful to investigate which acquisition protocol seems to be the more adapted and leads to precise results. The produced point clouds will be compared to photogrammetric surveys for the purpose of their accuracy assessment.

  19. Comparison of a digital and an optical analogue hand-held refractometer for the measurement of canine urine specific gravity.

    Science.gov (United States)

    Paris, J K; Bennett, A D; Dodkin, S J; Gunn-Moore, D A

    2012-05-05

    Urine specific gravity (USG) is used clinically as a measure of urine concentration, and is routinely assessed by refractometry. A comparison between optical analogue and digital refractometers for evaluation of canine urine has not been reported. The aim of this study was to compare a digital and an optical analogue hand-held refractometer for the measurement of canine USG, and to assess correlation with urine osmolality. Prospective study. Free-catch urine samples were collected from 285 hospitalised adult dogs, and paired USG readings were obtained with a digital and an optical analogue refractometer. In 50 dogs, urine osmolality was also measured using a freezing point depression osmometer. There was a small but statistically significant difference between the two refractometers (P<0.001), with the optical analogue refractometer reading higher than the digital refractometer (mean difference 0.0006, sd 0.0012). Paired refractometer measurements varied by <0.002 in 91.5 per cent of cases. The optical analogue and digital refractometer readings showed excellent correlation with osmolality (r=0.980 and r=0.977, respectively, P<0.001 in both cases). Despite statistical significance, the difference between the two refractometers is unlikely to be clinically significant. Both instruments provide an accurate assessment of USG in dogs.

  20. Linear Text vs. Non-Linear Hypertext in Handheld Computers: Effects on Declarative and Structural Knowledge, and Learner Motivation

    Science.gov (United States)

    Son, Chanhee; Park, Sanghoon; Kim, Minjeong

    2011-01-01

    This study compared linear text-based and non-linear hypertext-based instruction in a handheld computer regarding effects on two different levels of knowledge (declarative and structural knowledge) and learner motivation. Forty four participants were randomly assigned to one of three experimental conditions: linear text, hierarchical hypertext,…

  1. DNA aptamer beacon assay for C-telopeptide and handheld fluorometer to monitor bone resorption.

    Science.gov (United States)

    Bruno, John Gordon; Carrillo, Maria P; Phillips, Taylor; Hanson, Douglas; Bohmann, Jonathan A

    2011-09-01

    A novel DNA aptamer beacon is described for quantification of a 26-amino acid C-telopeptide (CTx) of human type I bone collagen. One aptamer sequence and its reverse complement dominated the aptamer pool (31.6% of sequenced clones). Secondary structures of these aptamers were examined for potential binding pockets. Three-dimensional computer models which analyzed docking topologies and binding energies were in agreement with empirical fluorescence experiments used to select one candidate loop for beacon assay development. All loop structures from the aptamer finalists were end-labeled with TYE 665 and Iowa Black quencher for comparison of beacon fluorescence levels as a function of CTx concentration. The optimal beacon, designated CTx 2R-2h yielded a low ng/ml limit of detection using a commercially available handheld fluorometer. The CTx aptamer beacon bound full-length 26-amino acid CTx peptide, but not a shorter 8-amino acid segment of CTx peptide which is a common target for commercial CTx ELISA kits. The prototype assay was shown to detect CTx peptide from human urine after creatinine and urea were removed by size-exclusion chromatography to prevent nonspecific denaturing of the aptamer beacon. This work demonstrates the potential of aptamer beacons to be utilized for rapid and sensitive bone health monitoring in a handheld or point-of-care format.

  2. Estimating the accuracy of optic nerve sheath diameter measurement using a pocket-sized, handheld ultrasound on a simulation model.

    Science.gov (United States)

    Johnson, Garrett G R J; Zeiler, Frederick A; Unger, Bertram; Hansen, Gregory; Karakitsos, Dimitrios; Gillman, Lawrence M

    2016-12-01

    Ultrasound measurement of optic nerve sheath diameter (ONSD) appears to be a promising, rapid, non-invasive bedside tool for identification of elevated intra-cranial pressure. With improvements in ultrasound technology, machines are becoming smaller; however, it is unclear if these ultra-portable handheld units have the resolution to make these measurements precisely. In this study, we estimate the accuracy of ONSD measurement in a pocket-sized ultrasound unit. Utilizing a locally developed, previously validated model of the eye, ONSD was measured by two expert observers, three times with two machines and on five models with different optic nerve sheath sizes. A pocket ultrasound (Vscan, GE Healthcare) and a standard portable ultrasound (M-Turbo, SonoSite) were used to measure the models. Data was analyzed by Bland-Altman plot and intra-class correlation coefficient (ICC). The ICC between raters for the SonoSite was 0.878, and for the Vscan was 0.826. The between-machine agreement ICC was 0.752. Bland-Altman agreement analysis between the two ultrasound methods showed an even spread across the range of sheath sizes, and that the Vscan tended to read on average 0.33 mm higher than the SonoSite for each measurement, with a standard deviation of 0.65 mm. Accurate ONSD measurement may be possible utilizing pocket-sized, handheld ultrasound devices despite their small screen size, lower resolution, and lower probe frequencies. Further study in human subjects is warranted for all newer handheld ultrasound models as they become available on the market.

  3. Design and Implementation of an Intelligent Windowsill System Using Smart Handheld Device and Fuzzy Microcontroller.

    Science.gov (United States)

    Wang, Jing-Min; Yang, Ming-Ta; Chen, Po-Lin

    2017-04-11

    With the advance of science and technology, people have a desire for convenient and comfortable living. Creating comfortable and healthy indoor environments is a major consideration for designing smart homes. As handheld devices become increasingly powerful and ubiquitous, this paper proposes an innovative use of smart handheld devices (SHD), using MIT App Inventor and fuzzy control, to perform the real-time monitoring and smart control of the designed intelligent windowsill system (IWS) in a smart home. A compact weather station that consists of environment sensors was constructed in the IWS for measuring of indoor illuminance, temperature-humidity, carbon dioxide (CO₂) concentration and outdoor rain and wind direction. According to the measured environment information, the proposed system can automatically send a command to a fuzzy microcontroller performed by Arduino UNO to fully or partly open the electric curtain and electric window for adapting to climate changes in the indoor and outdoor environment. Moreover, the IWS can automatically close windows for rain splashing on the window. The presented novel control method for the windowsill not only expands the SHD applications, but greatly enhances convenience to users. To validate the feasibility and effectiveness of the IWS, a laboratory prototype was built and confirmed experimentally.

  4. Influence of Fine Motor Skill on Accuracy of Measurements Using a Handheld Sliding Caliper at Adolescents Group Aged 19-20

    Science.gov (United States)

    Brychta, Petr; Hojk, Vladimír; Hrubý, Jiří; Pilc, Jozef

    2017-10-01

    This innovate ve interdisciplinary study deals with influence of fine motor skill level (finger dexterity) of individual on his measurement results in metrology practice. The main objective of this study was determinate fine motor skill level of individuals using a motor test. Further determinate the potential effect of different fine motor skill levels on accuracy of measuring using a mechanical handheld sliding caliper. Fine motor skill test and metrological test were implemented. Pursuant the results of fine motor skill test were probands divided into 2 groups. The groups are significantly different on accuracy of measurement (p=0,006). Pearson coefficient shows a significant correlation r = - 0.66 between the Purdue Pegboard test and a measurement error. Results confirmed that the fine motor skill of the upper limbs (especially finger coordination) significantly influence accuracy of measurement using a mechanical handheld sliding caliper.

  5. Comparison of low-cost handheld retinal camera and traditional table top retinal camera in the detection of retinal features indicating a risk of cardiovascular disease

    Science.gov (United States)

    Joshi, V.; Wigdahl, J.; Nemeth, S.; Zamora, G.; Ebrahim, E.; Soliz, P.

    2018-02-01

    Retinal abnormalities associated with hypertensive retinopathy are useful in assessing the risk of cardiovascular disease, heart failure, and stroke. Assessing these risks as part of primary care can lead to a decrease in the incidence of cardiovascular disease-related deaths. Primary care is a resource limited setting where low cost retinal cameras may bring needed help without compromising care. We compared a low-cost handheld retinal camera to a traditional table top retinal camera on their optical characteristics and performance to detect hypertensive retinopathy. A retrospective dataset of N=40 subjects (28 with hypertensive retinopathy, 12 controls) was used from a clinical study conducted at a primary care clinic in Texas. Non-mydriatic retinal fundus images were acquired using a Pictor Plus hand held camera (Volk Optical Inc.) and a Canon CR1-Mark II tabletop camera (Canon USA) during the same encounter. The images from each camera were graded by a licensed optometrist according to the universally accepted Keith-Wagener-Barker Hypertensive Retinopathy Classification System, three weeks apart to minimize memory bias. The sensitivity of the hand-held camera to detect any level of hypertensive retinopathy was 86% compared to the Canon. Insufficient photographer's skills produced 70% of the false negative cases. The other 30% were due to the handheld camera's insufficient spatial resolution to resolve the vascular changes such as minor A/V nicking and copper wiring, but these were associated with non-referable disease. Physician evaluation of the performance of the handheld camera indicates it is sufficient to provide high risk patients with adequate follow up and management.

  6. Beyond mere information provisioning: a handheld museum guide based on social activities and playful learning

    OpenAIRE

    SCHROYEN, Jolien; GABRIELS, Kris; TEUNKENS, Daniel; ROBERT, Karel; LUYTEN, Kris; CONINX, Karin

    2007-01-01

    During a museum visit, social interaction can improve intellectual, social, personal and cultural development. With the advances in technology, the use of personal mobile handheld devices – such as Personal Digital Assistants (PDAs) – that replace the traditional paper guidebooks is becoming a common sight at various heritage sites all over the world. This technology often leads to problems such as isolating visitors from their companions and distracting visitors away from their surroundings....

  7. First demonstration of real-time gamma imaging by using a handheld Compton camera for particle therapy

    Energy Technology Data Exchange (ETDEWEB)

    Taya, T., E-mail: taka48138@ruri.waseda.jp [Research Institute for Science and Engineering, Waseda University, 3-4-1 Okubo, Shinjuku, Tokyo 169-8555 (Japan); Kataoka, J.; Kishimoto, A.; Iwamoto, Y.; Koide, A. [Research Institute for Science and Engineering, Waseda University, 3-4-1 Okubo, Shinjuku, Tokyo 169-8555 (Japan); Nishio, T. [Graduate School of Biomedical and Health Science, Hiroshima University, 1-2-3, Kasumi, Minami-ku, Hiroshima-shi, Hiroshima (Japan); Kabuki, S. [School of Medicine, Tokai University, 143 Shimokasuya, Isehara-shi, Kanagawa (Japan); Inaniwa, T. [National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba-shi, Chiba (Japan)

    2016-09-21

    The use of real-time gamma imaging for cancer treatment in particle therapy is expected to improve the accuracy of the treatment beam delivery. In this study, we demonstrated the imaging of gamma rays generated by the nuclear interactions during proton irradiation, using a handheld Compton camera (14 cm×15 cm×16 cm, 2.5 kg) based on scintillation detectors. The angular resolution of this Compton camera is ∼8° at full width at half maximum (FWHM) for a {sup 137}Cs source. We measured the energy spectra of the gamma rays using a LaBr{sub 3}(Ce) scintillator and photomultiplier tube, and using the handheld Compton camera, performed image reconstruction when using a 70 MeV proton beam to irradiate a water, Ca(OH){sub 2}, and polymethyl methacrylate (PMMA) phantom. In the energy spectra of all three phantoms, we found an obvious peak at 511 keV, which was derived from annihilation gamma rays, and in the energy spectrum of the PMMA phantom, we found another peak at 718 keV, which contains some of the prompt gamma rays produced from {sup 10}B. Therefore, we evaluated the peak positions of the projection from the reconstructed images of the PMMA phantom. The differences between the peak positions and the Bragg peak position calculated using simulation are 7 mm±2 mm and 3 mm±8 mm, respectively. Although we could quickly acquire online gamma imaging of both of the energy ranges during proton irradiation, we cannot arrive at a clear conclusion that prompt gamma rays sufficiently trace the Bragg peak from these results because of the uncertainty given by the spatial resolution of the Compton camera. We will develop a high-resolution Compton camera in the near future for further study. - Highlights: • Gamma imaging during proton irradiation by a handheld Compton camera is demonstrated. • We were able to acquire the online gamma-ray images quickly. • We are developing a high resolution Compton camera for range verification.

  8. Handheld XRF analysis of a 16th century Mexican Feather Headdress

    International Nuclear Information System (INIS)

    Karydas, A.G; Padilla-Alvarez, R.; Drozdenko, M.; Korn, M.; Moreno Guzmán, M.O.

    2014-01-01

    The 16th century feather headdress in the Weltmuseum Wien (WMW), an affiliated institution of the Kunsthistorisches Museum (KHM) in Vienna, is the most renowned of the few remaining pre-Columbian “Arte Plumaria” artefacts, which were made by feather artisans (Amantecas) using traditional techniques in the territory of present day Mexico. The recorded history of the headdress begins in 1596, when it is first mentioned in the estate inventory of the art collection of Archduke Ferdinand II of Tyrol at Ambras Castle. Due to its age, the variety of materials used, its history and former restoration treatments, the artefact is today one of the most sensitive and demanding care objects of the museum. Despite the object’s long history, very little documentation on past interventions exists. From 2010-2012, a binational research project between Mexico (Instituto Nacional de Antropología e Historia) and Austria (Weltmuseum Wien) performed a systematic investigation focused on the identification of manufacturing techniques and the various materials, the old restoration measures and its conservation. Handheld x-ray fluorescence (XRF) spectrometers are extremely useful for the study of art works in museum collections. The possibility of bringing the instrument to inspect the objects on-site facilitates the study of artefacts that cannot be moved either due to their extreme fragility or due to their large size and/or weight. In addition, non-destructive analysis constitutes a preferred alternative to invasive sampling techniques, which are usually not allowed in the study of unique or extremely valuable objects. The aim of the XRF analysis was twofold: to investigate the possible presence of inorganic toxic elements that could be associated to the use of pesticides in past conservation interventions and; to characterize the chemical composition of the authentic gold and the gilded brass ornaments, which were added in the 19th century. The results of the XRF analytical

  9. On the use of spectra from portable Raman and ATR-IR instruments in synthesis route attribution of a chemical warfare agent by multivariate modeling.

    Science.gov (United States)

    Wiktelius, Daniel; Ahlinder, Linnea; Larsson, Andreas; Höjer Holmgren, Karin; Norlin, Rikard; Andersson, Per Ola

    2018-08-15

    Collecting data under field conditions for forensic investigations of chemical warfare agents calls for the use of portable instruments. In this study, a set of aged, crude preparations of sulfur mustard were characterized spectroscopically without any sample preparation using handheld Raman and portable IR instruments. The spectral data was used to construct Random Forest multivariate models for the attribution of test set samples to the synthetic method used for their production. Colored and fluorescent samples were included in the study, which made Raman spectroscopy challenging although fluorescence was diminished by using an excitation wavelength of 1064 nm. The predictive power of models constructed with IR or Raman data alone, as well as with combined data was investigated. Both techniques gave useful data for attribution. Model performance was enhanced when Raman and IR spectra were combined, allowing correct classification of 19/23 (83%) of test set spectra. The results demonstrate that data obtained with spectroscopy instruments amenable for field deployment can be useful in forensic studies of chemical warfare agents. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Object localization in handheld thermal images for fireground understanding

    Science.gov (United States)

    Vandecasteele, Florian; Merci, Bart; Jalalvand, Azarakhsh; Verstockt, Steven

    2017-05-01

    Despite the broad application of the handheld thermal imaging cameras in firefighting, its usage is mostly limited to subjective interpretation by the person carrying the device. As remedies to overcome this limitation, object localization and classification mechanisms could assist the fireground understanding and help with the automated localization, characterization and spatio-temporal (spreading) analysis of the fire. An automated understanding of thermal images can enrich the conventional knowledge-based firefighting techniques by providing the information from the data and sensing-driven approaches. In this work, transfer learning is applied on multi-labeling convolutional neural network architectures for object localization and recognition in monocular visual, infrared and multispectral dynamic images. Furthermore, the possibility of analyzing fire scene images is studied and their current limitations are discussed. Finally, the understanding of the room configuration (i.e., objects location) for indoor localization in reduced visibility environments and the linking with Building Information Models (BIM) are investigated.

  11. 3D handheld endoscope for optical coherence tomography of the human oral mucosa in vivo

    Science.gov (United States)

    Walther, Julia; Schnabel, Christian; Ebert, Nadja; Baumann, Michael; Koch, Edmund

    2017-07-01

    The early non-invasive diagnosis of epithelial tissue alterations in daily clinical routine is still challenging. Since optical coherence tomography (OCT) shows the potential to differentiate between benign and malignant tissue of primal endothelium, OCT could be beneficial for the early diagnosis of malignancies in routine health checks. In this research, a new handheld endoscopic scanning unit was designed and connected to a spectral domain OCT system of our workgroup for the in vivo imaging of the human oral mucosa.

  12. Towards Robust Self-Calibration for Handheld 3d Line Laser Scanning

    Science.gov (United States)

    Bleier, M.; Nüchter, A.

    2017-11-01

    This paper studies self-calibration of a structured light system, which reconstructs 3D information using video from a static consumer camera and a handheld cross line laser projector. Intersections between the individual laser curves and geometric constraints on the relative position of the laser planes are exploited to achieve dense 3D reconstruction. This is possible without any prior knowledge of the movement of the projector. However, inaccurrately extracted laser lines introduce noise in the detected intersection positions and therefore distort the reconstruction result. Furthermore, when scanning objects with specular reflections, such as glossy painted or metalic surfaces, the reflections are often extracted from the camera image as erroneous laser curves. In this paper we investiagte how robust estimates of the parameters of the laser planes can be obtained despite of noisy detections.

  13. Implementation of synthetic aperture imaging on a hand-held device

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian; Kjeldsen, Thomas; Larsen, Lee

    2014-01-01

    -held devices all with different chipsets and a BK Medical UltraView 800 ultrasound scanner emulating a wireless probe. The wireless transmission is benchmarked using an imaging setup consisting of 269 scan lines x 1472 complex samples (1.58 MB pr. frame, 16 frames per second). The measured data throughput...... reached an average of 28.8 MB/s using a LG G2 mobile device, which is more than the required data throughput of 25.3 MB/s. Benchmarking the processing performance for B-mode imaging showed a total processing time of 18.9 ms (53 frames/s), which is less than the acquisition time (62.5 ms).......This paper presents several implementations of Syn- thetic Aperture Sequential Beamforming (SASB) on commer- cially available hand-held devices. The implementations include real-time wireless reception of ultrasound radio frequency sig- nals and GPU processing for B-mode imaging. The proposed...

  14. Comparison of maximal voluntary isometric contraction and hand-held dynamometry in measuring muscle strength of patients with progressive lower motor neuron syndrome

    NARCIS (Netherlands)

    Visser, J.; Mans, E.; de Visser, M.; van den Berg-Vos, R. M.; Franssen, H.; de Jong, J. M. B. V.; van den Berg, L. H.; Wokke, J. H. J.; de Haan, R. J.

    2003-01-01

    Context. Maximal voluntary isometric contraction, a method quantitatively assessing muscle strength, has proven to be reliable, accurate and sensitive in amyotrophic lateral sclerosis. Hand-held dynamometry is less expensive and more quickly applicable than maximal voluntary isometric contraction.

  15. Handheld Devices and Video Modeling to Enhance the Learning of Self-Help Skills in Adolescents With Autism Spectrum Disorder.

    Science.gov (United States)

    Campbell, Joseph E; Morgan, Michele; Barnett, Veronica; Spreat, Scott

    2015-04-01

    The viewing of videos is a much-studied intervention to teach self-help, social, and vocational skills. Many of the studies to date looked at video modeling using televisions, computers, and other large screens. This study looked at the use of video modeling on portable handheld devices to teach hand washing to three adolescent students with an autism spectrum disorder. Three students participated in this 4-week study conducted by occupational therapists. Baseline data were obtained for the first student for 1 week, the second for 2 weeks, and the third for 3 weeks; videos were introduced when the participants each finished the baseline phase. Given the cognitive and motor needs of the participants, the occupational therapist set the player so that the participants only had to press the play button to start the video playing. The participants were able to hold the players and view at distances that were most appropriate for their individual needs and preferences. The results suggest that video modeling on a handheld device improves the acquisition of self-help skills.

  16. Possible Radiation-Induced Damage to the Molecular Structure of Wooden Artifacts Due to Micro-Computed Tomography, Handheld X-Ray Fluorescence, and X-Ray Photoelectron Spectroscopic Techniques

    Directory of Open Access Journals (Sweden)

    Madalena Kozachuk

    2016-05-01

    Full Text Available This study was undertaken to ascertain whether radiation produced by X-ray photoelectron spectroscopy (XPS, micro-computed tomography (μCT and/or portable handheld X-ray fluorescence (XRF equipment might damage wood artifacts during analysis. Changes at the molecular level were monitored by Fourier transform infrared (FTIR analysis. No significant changes in FTIR spectra were observed as a result of μCT or handheld XRF analysis. No substantial changes in the collected FTIR spectra were observed when XPS analytical times on the order of minutes were used. However, XPS analysis collected over tens of hours did produce significant changes in the FTIR spectra.

  17. Cellphone-based hand-held microplate reader for point-of-care ELISA testing (Conference Presentation)

    Science.gov (United States)

    Berg, Brandon; Cortazar, Bingen; Tseng, Derek; Ozkan, Haydar; Feng, Steve; Wei, Qingshan; Chan, Raymond Y.; Burbano, Jordi; Farooqui, Qamar; Lewinski, Michael; Di Carlo, Dino; Garner, Omai B.; Ozcan, Aydogan

    2016-03-01

    Enzyme-linked immunosorbent assay (ELISA) in a microplate format has been a gold standard first-line clinical test for diagnosis of various diseases including infectious diseases. However, this technology requires a relatively large and expensive multi-well scanning spectrophotometer to read and quantify the signal from each well, hindering its implementation in resource-limited-settings. Here, we demonstrate a cost-effective and handheld smartphone-based colorimetric microplate reader for rapid digitization and quantification of immunoserology-related ELISA tests in a conventional 96-well plate format at the point of care (POC). This device consists of a bundle of 96 optical fibers to collect the transmitted light from each well of the microplate and direct all the transmission signals from the wells onto the camera of the mobile-phone. Captured images are then transmitted to a remote server through a custom-designed app, and both quantitative and qualitative diagnostic results are returned back to the user within ~1 minute per 96-well plate by using a machine learning algorithm. We tested this mobile-phone based micro-plate reader in a clinical microbiology lab using FDA-approved mumps IgG, measles IgG, and herpes simplex virus IgG (HSV-1 and HSV-2) ELISA tests on 1138 remnant patient samples (roughly 50% training and 50% testing), and achieved an overall accuracy of ~99% or higher for each ELISA test. This handheld and cost-effective platform could be immediately useful for large-scale vaccination monitoring in low-infrastructure settings, and also for other high-throughput disease screening applications at POC.

  18. The Pixel Paradox and Transition-Metal Spectroscopy: One of Many Uses of the Handheld Digital Microscope in Chemical Demonstrations

    Science.gov (United States)

    Vitz, Ed

    2010-01-01

    A handheld digital microscope (HDM) interfaced to a computer with a presentation projector is used to project an out-of-focus yellow patch on the screen, then the patch is brought into focus to show that, paradoxically, there are red and green but no yellow pixels. Chromaticity diagrams are used to discuss this observation and spectroscopic…

  19. Handheld magnetic probe with permanent magnet and Hall sensor for identifying sentinel lymph nodes in breast cancer patients.

    Science.gov (United States)

    Sekino, Masaki; Kuwahata, Akihiro; Ookubo, Tetsu; Shiozawa, Mikio; Ohashi, Kaichi; Kaneko, Miki; Saito, Itsuro; Inoue, Yusuke; Ohsaki, Hiroyuki; Takei, Hiroyuki; Kusakabe, Moriaki

    2018-01-19

    The newly developed radioisotope-free technique based on magnetic nanoparticle detection using a magnetic probe is a promising method for sentinel lymph node biopsy. In this study, a novel handheld magnetic probe with a permanent magnet and magnetic sensor is developed to detect the sentinel lymph nodes in breast cancer patients. An outstanding feature of the probe is the precise positioning of the sensor at the magnetic null point of the magnet, leading to highly sensitive measurements unaffected by the strong ambient magnetic fields of the magnet. Numerical and experimental results show that the longitudinal detection length is approximately 10 mm, for 140 μg of iron. Clinical tests were performed, for the first time, using magnetic and blue dye tracers-without radioisotopes-in breast cancer patients to demonstrate the performance of the probe. The nodes were identified through transcutaneous and ex-vivo measurements, and the iron accumulation in the nodes was quantitatively revealed. These results show that the handheld magnetic probe is useful in sentinel lymph node biopsy and that magnetic techniques are widely being accepted as future standard methods in medical institutions lacking nuclear medicine facilities.

  20. Handheld optical coherence tomography-reflectance confocal microscopy probe for detection of basal cell carcinoma and delineation of margins

    Science.gov (United States)

    Iftimia, Nicusor; Yélamos, Oriol; Chen, Chih-Shan J.; Maguluri, Gopi; Cordova, Miguel A.; Sahu, Aditi; Park, Jesung; Fox, William; Alessi-Fox, Christi; Rajadhyaksha, Milind

    2017-07-01

    We present a hand-held implementation and preliminary evaluation of a combined optical coherence tomography (OCT) and reflectance confocal microscopy (RCM) probe for detecting and delineating the margins of basal cell carcinomas (BCCs) in human skin in vivo. A standard OCT approach (spectrometer-based) with a central wavelength of 1310 nm and 0.11 numerical aperture (NA) was combined with a standard RCM approach (830-nm wavelength and 0.9 NA) into a common path hand-held probe. Cross-sectional OCT images and enface RCM images are simultaneously displayed, allowing for three-dimensional microscopic assessment of tumor morphology in real time. Depending on the subtype and depth of the BCC tumor and surrounding skin conditions, OCT and RCM imaging are able to complement each other, the strengths of each helping overcome the limitations of the other. Four representative cases are summarized, out of the 15 investigated in a preliminary pilot study, demonstrating how OCT and RCM imaging may be synergistically combined to more accurately detect BCCs and more completely delineate margins. Our preliminary results highlight the potential benefits of combining the two technologies within a single probe to potentially guide diagnosis as well as treatment of BCCs.

  1. Handheld real-time volumetric 3-D gamma-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Haefner, Andrew, E-mail: ahaefner@lbl.gov [Lawrence Berkeley National Lab – Applied Nuclear Physics, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Barnowski, Ross [Department of Nuclear Engineering, UC Berkeley, 4155 Etcheverry Hall, MC 1730, Berkeley, CA 94720 (United States); Luke, Paul; Amman, Mark [Lawrence Berkeley National Lab – Applied Nuclear Physics, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Vetter, Kai [Department of Nuclear Engineering, UC Berkeley, 4155 Etcheverry Hall, MC 1730, Berkeley, CA 94720 (United States); Lawrence Berkeley National Lab – Applied Nuclear Physics, 1 Cyclotron Road, Berkeley, CA 94720 (United States)

    2017-06-11

    This paper presents the concept of real-time fusion of gamma-ray imaging and visual scene data for a hand-held mobile Compton imaging system in 3-D. The ability to obtain and integrate both gamma-ray and scene data from a mobile platform enables improved capabilities in the localization and mapping of radioactive materials. This not only enhances the ability to localize these materials, but it also provides important contextual information of the scene which once acquired can be reviewed and further analyzed subsequently. To demonstrate these concepts, the high-efficiency multimode imager (HEMI) is used in a hand-portable implementation in combination with a Microsoft Kinect sensor. This sensor, in conjunction with open-source software, provides the ability to create a 3-D model of the scene and to track the position and orientation of HEMI in real-time. By combining the gamma-ray data and visual data, accurate 3-D maps of gamma-ray sources are produced in real-time. This approach is extended to map the location of radioactive materials within objects with unknown geometry.

  2. Injection-depth-locking axial motion guided handheld micro-injector using CP-SSOCT.

    Science.gov (United States)

    Cheon, Gyeong Woo; Huang, Yong; Kwag, Hye Rin; Kim, Ki-Young; Taylor, Russell H; Gehlbach, Peter L; Kang, Jin U

    2014-01-01

    This paper presents a handheld micro-injector system using common-path swept source optical coherence tomography (CP-SSOCT) as a distal sensor with highly accurate injection-depth-locking. To achieve real-time, highly precise, and intuitive freehand control, the system used graphics processing unit (GPU) to process the oversampled OCT signal with high throughput and a smart customized motion monitoring control algorithm. A performance evaluation was conducted with 60-insertions and fluorescein dye injection tests to show how accurately the system can guide the needle and lock to the target depth. The evaluation tests show our system can guide the injection needle into the desired depth with 4.12 um average deviation error while injecting 50 nl of fluorescein dye.

  3. The Dragon’s Intentions: How China’s Past Is a Prologue for the Future

    Science.gov (United States)

    2012-05-17

    ways adequate to Christian standards, could be achieved without revealed religion.” 42 Voltaire’s1756 book, Essay on Morals, praised the Chinese for...Washington, D.C. 6 May 2011. Gertz, Bill. “China Supremacy.” The Washington Times, November 23, 2011. Hale, David D. and Lyric Hughes Hale

  4. Standard echocardiography versus handheld echocardiography for the detection of subclinical rheumatic heart disease: protocol for a systematic review.

    Science.gov (United States)

    Telford, Lisa H; Abdullahi, Leila H; Ochodo, Eleanor A; Zühlke, Liesl J; Engel, Mark E

    2018-02-10

    Rheumatic heart disease (RHD) is a preventable and treatable chronic condition which persists in many developing countries largely affecting impoverished populations. Handheld echocardiography presents an opportunity to address the need for more cost-effective methods of diagnosing RHD in developing countries, where the disease continues to carry high rates of morbidity and mortality. Preliminary studies have demonstrated moderate sensitivity as well as high specificity and diagnostic odds for detecting RHD in asymptomatic patients. We describe a protocol for a systematic review on the diagnostic performance of handheld echocardiography compared to standard echocardiography using the 2012 World Heart Federation criteria for diagnosing subclinical RHD. Electronic databases including PubMed, Scopus, Web of Science and EBSCOhost as well as reference lists and citations of relevant articles will be searched from 2012 to date using a predefined strategy incorporating a combination of Medical Subject Heading terms and keywords. The methodological validity and quality of studies deemed eligible for inclusion will be assessed against review specific Quality Assessment of Diagnostic Accuracy Studies 2 criteria and information on metrics of diagnostic accuracy and demographics extracted. Forest plots of sensitivity and specificity as well as scatter plots in receiver operating characteristic (ROC) space will be used to investigate heterogeneity. If possible, a meta-analysis will be conducted to produce summary results of sensitivity and specificity using the Hierarchical Summary ROC method. In addition, a sensitivity analysis will be conducted to investigate the effect of studies with a high risk of bias. Ethics approval is not required for this systematic review of previously published literature. The planned review will provide a summary of the diagnostic accuracy of handheld echocardiography. Results may feed into evidence-based guidelines and should the findings of this

  5. User-friendly tools on handheld devices for observer performance study

    Science.gov (United States)

    Matsumoto, Takuya; Hara, Takeshi; Shiraishi, Junji; Fukuoka, Daisuke; Abe, Hiroyuki; Matsusako, Masaki; Yamada, Akira; Zhou, Xiangrong; Fujita, Hiroshi

    2012-02-01

    ROC studies require complex procedures to select cases from many data samples, and to set confidence levels in each selected case to generate ROC curves. In some observer performance studies, researchers have to develop software with specific graphical user interface (GUI) to obtain confidence levels from readers. Because ROC studies could be designed for various clinical situations, it is difficult task for preparing software corresponding to every ROC studies. In this work, we have developed software for recording confidence levels during observer studies on tiny personal handheld devices such as iPhone, iPod touch, and iPad. To confirm the functions of our software, three radiologists performed observer studies to detect lung nodules by using public database of chest radiograms published by Japan Society of Radiological Technology. The output in text format conformed to the format for the famous ROC kit from the University of Chicago. Times required for the reading each case was recorded very precisely.

  6. Validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt.

    Science.gov (United States)

    Aramaki, Hidefumi; Katoh, Munenori; Hiiragi, Yukinobu; Kawasaki, Tsubasa; Kurihara, Tomohisa; Ohmi, Yorikatsu

    2016-07-01

    [Purpose] This study aimed to investigate the relatedness, reliability, and validity of isometric muscle strength measurements of hip abduction and abduction with an external hip rotation in a bent-hip position using a handheld dynamometer with a belt. [Subjects and Methods] Twenty healthy young adults, with a mean age of 21.5 ± 0.6 years were included. Isometric hip muscle strength in the subjects' right legs was measured under two posture positions using two devices: a handheld dynamometer with a belt and an isokinetic dynamometer. Reliability was evaluated using an intra-class correlation coefficient (ICC); relatedness and validity were evaluated using Pearson's product moment correlation coefficient. Differences in measurements of devices were assessed by two-way ANOVA. [Results] ICC (1, 1) was ≥0.9; significant positive correlations in measurements were found between the two devices under both conditions. No main effect was found between the measurement values. [Conclusion] Our findings revealed that there was relatedness, reliability, and validity of this method for isometric muscle strength measurements using a handheld dynamometer with a belt.

  7. Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices.

    Science.gov (United States)

    Mair, B; Drillich, M; Klein-Jöbstl, D; Kanz, P; Borchardt, S; Meyer, L; Schwendenwein, I; Iwersen, M

    2016-02-24

    Dairy cows have a massive demand for glucose at the onset of lactation. A poor adaption to this period leads to an excessive negative energy balance with an increased risk for ketosis and impaired animal health and production. Besides the measurement of ketones, analysing the glucose concentration in blood is reported as helpful instrument for diagnosis and differentiation of ketosis. Monitoring metabolic parameters requires multiple blood sampling. In other species, new blood sampling techniques have been introduced in which small amounts of blood are rapidly analysed using electronic hand-held devices. The objective of this study was to evaluate the suitability of capillary blood for blood glucose measurement in dairy cows using the hand-held devices FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini) and the WellionVet GLUCO CALEA, (WGC, MED TRUST). In total, 240 capillary blood samples were obtained from dry and fresh lactating Holstein-Friesian cows. Blood was collected from the skin of the exterior vulva by using a lancet. For method comparison, additional blood samples were taken from a coccygeal vessel and analyzed in a laboratory. Glucose concentrations measured by a standard laboratory method were defined as the criterion standard. The Pearson correlation coefficients between the glucose concentrations analyzed in capillary blood with the devices and the reference were 73% for the FSP, 81% for the GLX and 41% for the WGC. Bland-Altman plots showed biases of -18.8 mg/dL for the FSP, -11.2 mg/dL for the GLX and +20.82 mg/dL for the WGC. The optimized threshold determined by a Receiver Operating Characteristics analysis to detect hyperglycemia using the FSP was 43 mg/dL with a sensitivity (Se) and specificity (Sp) of 76 and 80%. Using the GLX and WGC optimized thresholds were 49 mg/dL (Se = 92%, Sp = 85%) and 95 mg/dL (Se = 39%, Sp = 92%). The results of this study demonstrate good performance characteristics for the GLX

  8. Utilizing Glove-Based Gestures and a Tactile Vest Display for Covert Communications and Robot Control

    Science.gov (United States)

    2014-06-01

    wearing instrumented glove for hand and arm signals. .......................................9 Figure 4. TDS Nomad handheld computer...of a standard tactical glove with accelerometers embedded within each finger, and an accelerometer, gyroscope, and digital compass embedded in the...signal communication were performed by two TDS Nomad GPS-enabled ruggedized handheld computers (one carried by the individual generating hand signals and

  9. Faculty Tort Liability for Libelous Student Publications

    Science.gov (United States)

    Stevens, George E.

    1976-01-01

    Examines recent court cases to determine whether a school administrator or faculty advisor may be legally responsible for defamation in a student publication. Concludes that the legal position of faculty members is unclear and recommends application of the U.S. Supreme Court's guidelines in Gertz v. Robert Welch, Inc. (JG)

  10. A simple hand-held magnet array for efficient and reproducible SABRE hyperpolarisation using manual sample shaking.

    Science.gov (United States)

    Richardson, Peter M; Jackson, Scott; Parrott, Andrew J; Nordon, Alison; Duckett, Simon B; Halse, Meghan E

    2018-07-01

    Signal amplification by reversible exchange (SABRE) is a hyperpolarisation technique that catalytically transfers nuclear polarisation from parahydrogen, the singlet nuclear isomer of H 2 , to a substrate in solution. The SABRE exchange reaction is carried out in a polarisation transfer field (PTF) of tens of gauss before transfer to a stronger magnetic field for nuclear magnetic resonance (NMR) detection. In the simplest implementation, polarisation transfer is achieved by shaking the sample in the stray field of a superconducting NMR magnet. Although convenient, this method suffers from limited reproducibility and cannot be used with NMR spectrometers that do not have appreciable stray fields, such as benchtop instruments. Here, we use a simple hand-held permanent magnet array to provide the necessary PTF during sample shaking. We find that the use of this array provides a 25% increase in SABRE enhancement over the stray field approach, while also providing improved reproducibility. Arrays with a range of PTFs were tested, and the PTF-dependent SABRE enhancements were found to be in excellent agreement with comparable experiments carried out using an automated flow system where an electromagnet is used to generate the PTF. We anticipate that this approach will improve the efficiency and reproducibility of SABRE experiments carried out using manual shaking and will be particularly useful for benchtop NMR, where a suitable stray field is not readily accessible. The ability to construct arrays with a range of PTFs will also enable the rapid optimisation of SABRE enhancement as function of PTF for new substrate and catalyst systems. © 2017 The Authors Magnetic Resonance in Chemistry Published by John Wiley & Sons Ltd.

  11. Poor correlation between intracranial pressure and intraocular pressure by hand-held tonometry

    Directory of Open Access Journals (Sweden)

    Golan S

    2013-06-01

    Full Text Available Shani Golan,1 Shimon Kurtz,1 Daphna Mezad-Koursh,1 Michael Waisbourd,1 Anat Kesler,1 Pinchas Halpern2 1Departments of Ophthalmology, Tel Aviv Sourasky Medical Center, affiliated with the Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel; 2Emergency Medicine, Tel Aviv Sourasky Medical Center, affiliated with the Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel Purpose: The aim of this study is to provide data on the controversial issue of whether handheld measurements of intraocular pressure (IOP are capable of accurately predicting elevated intracranial pressure (ICP in patients undergoing lumbar puncture (LP. Methods: All patients over the age of 18 years who underwent an LP in the emergency or neurological departments at the Tel Aviv Medical center for any reason between October 2007 and July 2010 were eligible to participate in this prospective observational pilot study. IOP was measured with the Tono-Pen XL while patients were in the supine position before undergoing LP. ICP was measured in the lateral recumbent position. ICP and bilateral IOP were measured, and the mean and maximum values of IOP were calculated. The association between ICP and each one of the four IOP measures was evaluated by the Pearson correlation coefficient. Results: Twenty-four patients (mean age 37.8 ± 15.8 years, ten males and 14 females were enrolled. The reasons for their requiring an LP were headache (19/24 patients, evaluation for hemiparesis (2/24, cognitive deterioration (1/24, and seizures (2/24. Nine had elevated mean opening pressure (>20 cm H2O, six had an elevated mean IOP (>20 mmHg, and four of these six also had an elevated opening pressure. There was no significant correlation between the ICP measurements and any of the IOP measurements. Conclusion: Handheld ocular tonometry has poor sensitivity and specificity for the prediction of increased ICP and is not an effective tool for screening for ICP in the ED or in the

  12. Compact printed two dipole array antenna with a high front-back ratio for ultra-high-frequency radio-frequency identification handheld reader applications

    DEFF Research Database (Denmark)

    Liu, Qi; Zhang, Shuai; He, Sailing

    2015-01-01

    A printed two-dipole array antenna with a high front-back ratio is proposed for ultra-high-frequency (UHF) radio-frequency identification handheld readers. The proposed antenna is a parasitic dual-element array with the ends of both elements folded back towards each other for additional coupling....

  13. A hand-held sensor for analyses of local distributions of magnetic fields and losses

    CERN Document Server

    Krismanic, G; Baumgartinger, N

    2000-01-01

    The paper describes a novel sensor for non-destructive analyses of local field and loss distributions in laminated soft magnetic cores, such as transformer cores. It was designed for rapid information on comparative local degrees of inhomogeneity, e.g., for the estimation of local building factors. Similar to a magnifying glass with handle, the compact hand-held sensor contains extremely sharp needle electrodes for the detection of the induction vector B as well as double-field coils for the vector H. Losses P are derived from the Poynting law. Applied to inner -- or also outer -- core regions, the sensor yields instantaneous computer displays of local H, B, and P.

  14. Detection of cadmium sulphide nanoparticles by using screen-printed electrodes and a handheld device

    International Nuclear Information System (INIS)

    Merkoci, Arben; Marcolino-Junior, Luiz Humberto; MarIn, Sergio; Fatibello-Filho, Orlando; Alegret, Salvador

    2007-01-01

    A simple method based on screen-printed electrodes and a handheld potentiostatic device is reported for the detection of water soluble CdS quantum dots modified with glutathione. The detection method is based on the stripping of electrochemically reduced cadmium at pH 7.0 by using square wave voltammetry. Various parameters that affect the sensitivity of the method are optimized. QD suspension volumes of 20 μl and a number of around 2 x 10 11 CdS quantum dots have been able to be detected. The proposed method should be of special interest for bioanalytical assays, where CdS quantum dots can be used as electrochemical tracers

  15. Reliability of measuring hip abductor strength following total knee arthroplasty using a hand-held dynamometer.

    Science.gov (United States)

    Schache, Margaret B; McClelland, Jodie A; Webster, Kate E

    2016-01-01

    To investigate the test-retest reliability of measuring hip abductor strength in patients with total knee arthroplasty (TKA) using a hand-held dynamometer (HHD) with two different types of resistance: belt and manual resistance. Test-retest reliability of 30 subjects (17 female, 13 male, 71.9 ± 7.4 years old), 9.2 ± 2.7 days post TKA was measured using belt and therapist resistance. Retest reliability was calculated with intra-class coefficients (ICC3,1) and 95% confidence intervals (CI) for both the group average and the individual scores. A paired t-test assessed whether a difference existed between the belt and therapist methods of resistance. ICCs were 0.82 and 0.80 for the belt and therapist resisted methods, respectively. Hip abductor strength increases of 8 N (14%) for belt resisted and 14 N (17%) for therapist resisted measurements of the group average exceeded the 95% CI and may represent real change. For individuals, hip abductor strength increases of 33 N (72%) (belt resisted) and 57 N (79%) (therapist resisted) could be interpreted as real change. Hip abductor strength can be reliably measured using HHD in the clinical setting with the described protocol. Belt resistance demonstrated slightly higher test-retest reliability. Reliable measurement of hip abductor muscle strength in patients with TKA is important to ensure deficiencies are addressed in rehabilitation programs and function is maximized. Hip abductor strength can be reliably measured with a hand-held dynamometer in the clinical setting using manual or belt resistance.

  16. A review of the use of handheld computers in medical nutrition.

    Science.gov (United States)

    Holubar, Stefan; Harvey-Banchik, Lillian

    2007-08-01

    Handheld computers, or personal digital assistants (PDAs), have been used to assist clinicians in medical nutrition since the early 1980s. The term PDA was originally applied to programmable calculators; over time, the capabilities of these devices were expanded to allow for the use of more complicated programs such as databases, spreadsheets, and electronic books. Slowly, the device evolved into what is more commonly thought of as a PDA, that is, a device such as a PalmOS (PalmSource, Inc, Tokyo, Japan) or PocketPC (Microsoft, Redmond, WA) unit. We present a review of the literature about the use of PDAs in medical nutrition, followed by a discussion of the different types of PDAs and mobile technologies that are commercially available. This is followed by a discussion of software applications that are currently available for use by nutrition clinicians, focusing on freeware applications. Finally, future technologies and applications are discussed.

  17. Potential air contamination during CO2 angiography using a hand-held syringe: theoretical considerations and gas chromatography.

    Science.gov (United States)

    Cho, David R; Cho, Kyung J; Hawkins, Irvin F

    2006-01-01

    To assess air contamination in the hand-held syringes currently used for CO2 delivery and to determine whether there is an association between their position and the rate of air contamination. Assessment of air contamination in the syringe (20 ml) included theoretical modeling, mathematical calculation, and gas chromatography (GC). The model was used with Fick's first law to calculate the diffusion of CO2 and the amount of air contamination. For GC studies, the syringes were placed in the upright, horizontal, and inverted positions and gas samples were obtained after 5, 10, 20, 30, and 60 min. All trials with each position for each sampling time were performed five times. The amounts of air contamination with time calculated mathematically were 5-10% less than those of GC. With the diffusivity of air-CO2 at 0.1599 cm2/sec (9.594 cm2/min), air contamination was calculated to be 60% at 60 min. With GC air contamination was 13% at 5 min, 31% at 20 min, 43% at 30 min, and 68% at 60 min. There was no difference in air contamination between the different syringe positions. Air contamination occurs in hand-held syringes filled with CO2 when they are open to the ambient air. The amounts of air contamination over time are similar among syringes placed in the upright, horizontal, and inverted positions.

  18. Science education with handheld devices: A comparison of Nintendo WiiMote and iPod touch for kinematics learning

    OpenAIRE

    Hochberg, K.; Kuhn, J.; Müller, A.

    2016-01-01

    Experiential science learning based on the in-built sensors of handheld devices such as smartphones, tablet computer and game consoles has seen quite a strong development in recent years. In particular, such devices with internal acceleration sensors offer an innovative approach to kinematics learning in classroom physics, a notoriously difficult topic for pupils. In view of research and teaching in this domain, the practical advantages and disadvantages of two such devices, the Nintendo WiiM...

  19. Interpreting Mobile and Handheld Air Sensor Readings in Relation to Air Quality Standards and Health Effect Reference Values: Tackling the Challenges

    Directory of Open Access Journals (Sweden)

    George M. Woodall

    2017-09-01

    Full Text Available The US Environmental Protection Agency (EPA and other federal agencies face a number of challenges in interpreting and reconciling short-duration (seconds to minutes readings from mobile and handheld air sensors with the longer duration averages (hours to days associated with the National Ambient Air Quality Standards (NAAQS for the criteria pollutants-particulate matter (PM, ozone, carbon monoxide, lead, nitrogen oxides, and sulfur oxides. Similar issues are equally relevant to the hazardous air pollutants (HAPs where chemical-specific health effect reference values are the best indicators of exposure limits; values which are often based on a lifetime of continuous exposure. A multi-agency, staff-level Air Sensors Health Group (ASHG was convened in 2013. ASHG represents a multi-institutional collaboration of Federal agencies devoted to discovery and discussion of sensor technologies, interpretation of sensor data, defining the state of sensor-related science across each institution, and provides consultation on how sensors might effectively be used to meet a wide range of research and decision support needs. ASHG focuses on several fronts: improving the understanding of what hand-held sensor technologies may be able to deliver; communicating what hand-held sensor readings can provide to a number of audiences; the challenges of how to integrate data generated by multiple entities using new and unproven technologies; and defining best practices in communicating health-related messages to various audiences. This review summarizes the challenges, successes, and promising tools of those initial ASHG efforts and Federal agency progress on crafting similar products for use with other NAAQS pollutants and the HAPs. NOTE: The opinions expressed are those of the authors and do not necessary represent the opinions of their Federal Agencies or the US Government. Mention of product names does not constitute endorsement.

  20. Reliability of a novel thermal imaging system for temperature assessment of healthy feet.

    Science.gov (United States)

    Petrova, N L; Whittam, A; MacDonald, A; Ainarkar, S; Donaldson, A N; Bevans, J; Allen, J; Plassmann, P; Kluwe, B; Ring, F; Rogers, L; Simpson, R; Machin, G; Edmonds, M E

    2018-01-01

    Thermal imaging is a useful modality for identifying preulcerative lesions ("hot spots") in diabetic foot patients. Despite its recognised potential, at present, there is no readily available instrument for routine podiatric assessment of patients at risk. To address this need, a novel thermal imaging system was recently developed. This paper reports the reliability of this device for temperature assessment of healthy feet. Plantar skin foot temperatures were measured with the novel thermal imaging device (Diabetic Foot Ulcer Prevention System (DFUPS), constructed by Photometrix Imaging Ltd) and also with a hand-held infrared spot thermometer (Thermofocus® 01500A3, Tecnimed, Italy) after 20 min of barefoot resting with legs supported and extended in 105 subjects (52 males and 53 females; age range 18 to 69 years) as part of a multicentre clinical trial. The temperature differences between the right and left foot at five regions of interest (ROIs), including 1st and 4th toes, 1st, 3rd and 5th metatarsal heads were calculated. The intra-instrument agreement (three repeated measures) and the inter-instrument agreement (hand-held thermometer and thermal imaging device) were quantified using intra-class correlation coefficients (ICCs) and the 95% confidence intervals (CI). Both devices showed almost perfect agreement in replication by instrument. The intra-instrument ICCs for the thermal imaging device at all five ROIs ranged from 0.95 to 0.97 and the intra-instrument ICCs for the hand-held-thermometer ranged from 0.94 to 0.97. There was substantial to perfect inter-instrument agreement between the hand-held thermometer and the thermal imaging device and the ICCs at all five ROIs ranged between 0.94 and 0.97. This study reports the performance of a novel thermal imaging device in the assessment of foot temperatures in healthy volunteers in comparison with a hand-held infrared thermometer. The newly developed thermal imaging device showed very good agreement in

  1. WWC Review of the Report "Conceptualizing Astronomical Scale: Virtual Simulations on Handheld Tablet Computers Reverse Misconceptions." What Works Clearinghouse Single Study Review

    Science.gov (United States)

    What Works Clearinghouse, 2014

    2014-01-01

    The 2014 study, "Conceptualizing Astronomical Scale: Virtual Simulations on Handheld Tablet Computers Reverse Misconceptions," examined the effects of using the true-to-scale (TTS) display mode versus the orrery display mode in the iPad's Solar Walk software application on students' knowledge of the Earth's place in the solar system. The…

  2. Clinical effectiveness of the Respimat® inhaler device in managing chronic obstructive pulmonary disease: evidence when compared with other handheld inhaler devices

    Directory of Open Access Journals (Sweden)

    et al

    2011-02-01

    Full Text Available Felix SF Ram1, Celso R Carvallho2, John White31School of Health and Social Services, Massey University, Auckland, New Zealand; 2Department of Physical Therapy, School of Medicine, University of São Paulo, Brazil; 3York Hospitals NHS Foundation Trust, York Hospital, York, UKObjectives: Medication for the management of chronic obstructive pulmonary disease (COPD may be delivered by a number of different inhaler devices. This study was undertaken to determine the clinical effectiveness of the Respimat® handheld inhaler device compared with other handheld inhaler devices for the delivery of medication in stable COPD.Methodology: A systematic review of high-quality randomized controlled clinical trials comparing Respimat with other inhaler devices using the same medication was performed. Studies were searched for in the Cochrane Central Register of Controlled Trials as well as other relevant electronic databases. Manufacturers of inhaled COPD medication were also contacted for potential trials.Results: Seven studies of high methodological quality with 3813 participants were included in the review. Three trials used Handihaler® as the comparator inhaler, three used a chlorofluorocarbon metered-dose inhaler (CFC-MDI, and one trial used a hydroflouroalkane (HFA-MDI. When Respimat was compared with Handihaler, the following reported outcomes were not significantly different: trough forced expiratory volume in 1 second (FEV1 (weighted mean difference [WMD] 0.01 L; P = 0.14, trough forced vital capacity (FVC (WMD 0.001 L: P = 0.88, peak FEV1 (WMD 0.01 L: P = 0.08, peak FVC (WMD 0.01 L: P = 0.55, morning peak expiratory flow rate (PEFR (WMD 5.06 L/min: P = 0.08, and evening PEFR (WMD 4.39 L/min: P = 0.15. Furthermore, there were no differences when Respimat was compared with Handihaler for risk of exacerbations (relative risk [RR] 0.94: P = 0.81, dry mouth (RR 1.57: P = 0.34, or nasopharyngitis (RR 1.42: P = 0.22. For Respimat compared with CFC-MDI, the

  3. Analysis of shipboard aerosol optical thickness measurements from multiple sunphotometers aboard the R/V Ronald H. Brown during the Aerosol Characterization Experiment - Asia

    International Nuclear Information System (INIS)

    Miller, Mark A.; Knobelspiesse, Kirk; Frouin, Robert; Bartholomew, Mary Jane; Reynolds, R. Michael; Pietras, Christophe; Fargion, Giulietta; Quinn, Patricia; Thieuleux, Francois

    2005-01-01

    Marine sunphotometer measurements collected aboard the R/V Ronald H. Brown during the Aerosol Characterization Experiment - Asia (ACE-Asia) are used to evaluate the ability of complementary instrumentation to obtain the best possible estimates of aerosol optical thickness and Angstrom exponent from ships at sea. A wide range of aerosol conditions, including clean maritime conditions and highly polluted coastal environments, were encountered during the ACE-Asia cruise. The results of this study suggest that shipboard hand-held sunphotometers and fast-rotating shadow-band radiometers (FRSRs) yield similar measurements and uncertainties if proper measurement protocols are used and if the instruments are properly calibrated. The automated FRSR has significantly better temporal resolution (2 min) than the hand-held sunphotometers when standard measurement protocols are used, so it more faithfully represents the variability of the local aerosol structure in polluted regions. Conversely, results suggest that the hand-held sunphotometers may perform better in clean, maritime air masses for unknown reasons. Results also show that the statistical distribution of the Angstrom exponent measurements is different when the distributions from hand-held sunphotometers are compared with those from the FRSR and that the differences may arise from a combination of factors

  4. Photoacoustic cystography using handheld dual modal clinical ultrasound photoacoustic imaging system

    Science.gov (United States)

    Sivasubramanian, Kathyayini; Periyasamy, Vijitha; Austria, Dienzo Rhonnie; Pramanik, Manojit

    2018-02-01

    Vesicoureteral reflux is the abnormal flow of urine from your bladder back up the tubes (ureters) that connect your kidneys to your bladder. Normally, urine flows only down from your kidneys to your bladder. Vesicoureteral reflux is usually diagnosed in infants and children. The disorder increases the risk of urinary tract infections, which, if left untreated, can lead to kidney damage. X-Ray cystography is used currently to diagnose this condition which uses ionising radiation, making it harmful for patients. In this work we demonstrate the feasibility of imaging the urinary bladder using a handheld clinical ultrasound and photoacoustic dual modal imaging system in small animals (rats). Additionally, we demonstrate imaging vesicoureteral reflux using bladder mimicking phantoms. Urinary bladder imaging is done with the help of contrast agents like black ink and gold nanoparticles which have high optical absorption at 1064 nm. Imaging up to 2 cm was demonstrated with this system. Imaging was done at a framerate of 5 frames per second.

  5. Characterizing infantile hemangiomas with a near-infrared spectroscopic handheld wireless device

    Science.gov (United States)

    Fong, Christopher J.; Hoi, Jennifer W.; Kim, Hyun K.; Behr, Gerald; Geller, Lauren; Antonov, Nina; Flexman, Molly; Garzon, Maria; Hielscher, Andreas H.

    2015-03-01

    Infantile hemangiomas (IH) are common vascular growths that occur in 5-10% of neonates and have the potential to cause disfiguring and even life-threatening complications. Currently, no objective tool exist to monitor either progression or treatment of IH. To address this unmet clinical need, we have developed a handheld wireless device (HWD) that uses diffuse optical spectroscopy for the assessment of IH. The system employs 4 wavelengths (l=780nm, 805nm, 850nm, and 905nm) and 6 source-detector pairs with distances between 0.6 and 20 mm. Placed on the skin surface, backreflection data is obtained and a multispectral evolution algorithm is used to determine total hemoglobin concentration and tissue oxygen saturation. First results of an ongoing pilot study involving 13 patients (average enrollment age = 25 months) suggest that an increase in hypoxic stress over time can lead to the proliferation of IH. Involuting IH lesions showed an increase in tissue oxygen saturation as well as a decrease in total hemoglobin.

  6. Textbooks on tap: using electronic books housed in handheld devices in nursing clinical courses.

    Science.gov (United States)

    Williams, Margaret G; Dittmer, Arlis

    2009-01-01

    Changing technology is creating new ways to approach nursing education and practice. Beginning in 2003, using a quasi-experimental design, this project introduced personal digital assistants (PDAs) as a clinical tool to five experimental and control groups of students and faculty. The handheld device, or PDA, was loaded with e-books for clinical practice. Differences in learning styles and preferences emerged during the different phases of the study. Students were quickly able to master the technology and use the device effectively, reporting that they liked the concise nature of the information obtained. No students expressed dissatisfaction or regret at being in the experimental group. Results and implications for clinical practice, education, and library resources are discussed.

  7. Biosensors for EVA: Improved Instrumentation for Ground-based Studies

    Science.gov (United States)

    Soller, B.; Ellerby, G.; Zou, F.; Scott, P.; Jin, C.; Lee, S. M. C.; Coates, J.

    2010-01-01

    During lunar excursions in the EVA suit, real-time measurement of metabolic rate is required to manage consumables and guide activities to ensure safe return to the base. Metabolic rate, or oxygen consumption (VO2), is normally measured from pulmonary parameters but cannot be determined with standard techniques in the oxygen-rich environment of a spacesuit. Our group has developed novel near infrared spectroscopic (NIRS) methods to calculate muscle oxygen saturation (SmO 2), hematocrit, and pH, and we recently demonstrated that we can use our NIRS sensor to measure VO 2 on the leg during cycling. Our NSBRI project has 4 objectives: (1) increase the accuracy of the metabolic rate calculation through improved prediction of stroke volume; (2) investigate the relative contributions of calf and thigh oxygen consumption to metabolic rate calculation for walking and running; (3) demonstrate that the NIRS-based noninvasive metabolic rate methodology is sensitive enough to detect decrement in VO 2 in a space analog; and (4) improve instrumentation to allow testing within a spacesuit. Over the past year we have made progress on all four objectives, but the most significant progress was made in improving the instrumentation. The NIRS system currently in use at JSC is based on fiber optics technology. Optical fiber bundles are used to deliver light from a light source in the monitor to the patient, and light reflected back from the patient s muscle to the monitor for spectroscopic analysis. The fiber optic cables are large and fragile, and there is no way to get them in and out of the test spacesuit used for ground-based studies. With complimentary funding from the US Army, we undertook a complete redesign of the sensor and control electronics to build a novel system small enough to be used within the spacesuit and portable enough to be used by a combat medic. In the new system the filament lamp used in the fiber optic system was replaced with a novel broadband near infrared

  8. Direction-Sensitive Hand-Held Gamma-Ray Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mukhopadhyay, S.

    2012-10-04

    A novel, light-weight, hand-held gamma-ray detector with directional sensitivity is being designed. The detector uses a set of multiple rings around two cylindrical surfaces, which provides precise location of two interaction points on two concentric cylindrical planes, wherefrom the source location can be traced back by back projection and/or Compton imaging technique. The detectors are 2.0 × 2.0 mm europium-doped strontium iodide (SrI2:Eu2+) crystals, whose light output has been measured to exceed 120,000 photons/MeV, making it one of the brightest scintillators in existence. The crystal’s energy resolution, less than 3% at 662 keV, is also excellent, and the response is highly linear over a wide range of gamma-ray energies. The emission of SrI2:Eu2+ is well matched to both photo-multiplier tubes and blue-enhanced silicon photodiodes. The solid-state photomultipliers used in this design (each 2.0 × 2.0 mm) are arrays of active pixel sensors (avalanche photodiodes driven beyond their breakdown voltage in reverse bias); each pixel acts as a binary photon detector, and their summed output is an analog representation of the total photon energy, while the individual pixel accurately defines the point of interaction. A simple back-projection algorithm involving cone-surface mapping is being modeled. The back projection for an event cone is a conical surface defining the possible location of the source. The cone axis is the straight line passing through the first and second interaction points.

  9. Handheld Devices with Wide-Area Wireless Connectivity: Applications in Astronomy Educational Technology and Remote Computational Control

    Science.gov (United States)

    Budiardja, R. D.; Lingerfelt, E. J.; Guidry, M. W.

    2003-05-01

    Wireless technology implemented with handheld devices has attractive features because of the potential to access large amounts of data and the prospect of on-the-fly computational analysis from a device that can be carried in a shirt pocket. We shall describe applications of such technology to the general paradigm of making digital wireless connections from the field to upload information and queries to network servers, executing (potentially complex) programs and controlling data analysis and/or database operations on fast network computers, and returning real-time information from this analysis to the handheld device in the field. As illustration, we shall describe several client/server programs that we have written for applications in teaching introductory astronomy. For example, one program allows static and dynamic properties of astronomical objects to be accessed in a remote observation laboratory setting using a digital cell phone or PDA. Another implements interactive quizzing over a cell phone or PDA using a 700-question introductory astronomy quiz database, thus permitting students to study for astronomy quizzes in any environment in which they have a few free minutes and a digital cell phone or wireless PDA. Another allows one to control and monitor a computation done on a Beowulf cluster by changing the parameters of the computation remotely and retrieving the result when the computation is done. The presentation will include hands-on demonstrations with real devices. *Managed by UT-Battelle, LLC, for the U.S. Department of Energy under contract DE-AC05-00OR22725.

  10. Potential Air Contamination During CO2 Angiography Using a Hand-Held Syringe: Theoretical Considerations and Gas Chromatography

    International Nuclear Information System (INIS)

    Cho, David R.; Cho, Kyung J.; Hawkins, Irvin F.

    2006-01-01

    Purpose. To assess air contamination in the hand-held syringes currently used for CO 2 delivery and to determine whether there is an association between their position and the rate of air contamination. Methods. Assessment of air contamination in the syringe (20 ml) included theoretical modeling, mathematical calculation, and gas chromatography (GC). The model was used with Fick's first law to calculate the diffusion of CO 2 and the amount of air contamination. For GC studies, the syringes were placed in the upright, horizontal, and inverted positions and gas samples were obtained after 5, 10, 20, 30, and 60 min. All trials with each position for each sampling time were performed five times. Results. The amounts of air contamination with time calculated mathematically were 5-10% less than those of GC. With the diffusivity of air-CO 2 at 0.1599 cm 2 /sec (9.594 cm 2 /min), air contamination was calculated to be 60% at 60 min. With GC air contamination was 13% at 5 min, 31% at 20 min, 43% at 30 min, and 68% at 60 min. There was no difference in air contamination between the different syringe positions. Conclusion. Air contamination occurs in hand-held syringes filled with CO 2 when they are open to the ambient air. The amounts of air contamination over time are similar among syringes placed in the upright, horizontal, and inverted positions

  11. Development and performance of a hand-held CZT detector for in-situ measurements at the emergency response

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Young Yong; Chung, Kun Ho; Kim, Chang Jong; Lee, Wan No; Choi, Geun Sik; Kang, Mun Ja [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Yoon, Jin [SI Detection Co. Ltd, Daejeon (Korea, Republic of)

    2016-06-15

    A hand-held detector for an emergency response was developed for nuclide identification and to estimate the information of the ambient dose rate in the scene of an accident as well as the radioactivity of the contaminants. To achieve this, the most suitable sensor was first selected as a cadmium zinc telluride (CZT) semiconductor and the signal processing unit from a sensor and the signal discrimination and storage unit were successfully manufactured on a printed circuit board. The performance of the developed signal processing unit was then evaluated to have an energy resolution of about 14 keV at 662 keV. The system control unit was also designed to operate the CZT detector, monitor the detector, battery, and interface status, and check and transmit the measured results of the ambient dose rate and radioactivity. In addition, a collimator, which can control the inner radius, and the airborne dust sampler, which consists of an air filter and charcoal filter, were developed and mounted to the developed CZT detector for the quick and efficient response of a nuclear accident. The hand-held CZT detector was developed to make the in-situ gamma-ray spectrometry and its performance was checked to have a good energy resolution. In addition, the collimator and the airborne dust sampler were developed and mounted to the developed CZT detector for a quick and efficient response to a nuclear accident.

  12. Surgical instrument biocontaminant fluorescence detection in ambient lighting conditions for hospital reprocessing and sterilization department (Conference Presentation)

    Science.gov (United States)

    Baribeau, François; Bubel, Annie; Dumont, Guillaume; Vachon, Carl; Lépine, André; Rochefort, Stéphane; Massicotte, Martin; Buteau-Vaillancourt, Louis; Gallant, Pascal; Mermut, Ozzy

    2017-03-01

    Hospitals currently rely on simple human visual inspection for assessing cleanliness of surgical instruments. Studies showed that surgical site infections are in part attributed to inadequate cleaning of medical devices. Standards groups recognize the need to objectively quantify the amount of residues on surgical instruments and establish guidelines. We developed a portable technology for the detection of contaminants on surgical instruments through fluorescence following cleaning. Weak fluorescence signals are usually detected in the obscurity only with the lighting of the excitation source. The key element of this system is that it works in ambient lighting conditions, a requirement to not disturb the normal workflow of hospital reprocessing facilities. A biocompatible fluorescent dye is added to the detergent and labels the proteins of organic residues. It is resistant to the harsh environment in a washer-disinfector. Two inspection devices have been developed with a 488nm laser as the excitation source: a handheld scanner and a tabletop station using spectral-domain and time-domain ambient light cancellation schemes. The systems are eye safe and equipped with image processing and interfacing software to provide visual or audible warnings to the operator based on a set of adjustable signal thresholds. Micron-scale residues are detected by the system which can also evaluate soil size and mass. Unlike swabbing, it can inspect whole tools in real-time. The technology has been validated in an independent hospital decontamination research laboratory. It also has potential applications in the forensics, agro-food, and space fields. Technical aspects and results will be presented and discussed.

  13. PET-Probe: Evaluation of Technical Performance and Clinical Utility of a Handheld High-Energy Gamma Probe in Oncologic Surgery.

    Science.gov (United States)

    Gulec, Seza A; Daghighian, Farhad; Essner, Richard

    2016-12-01

    Positron emission tomography (PET) has become an invaluable part of patient evaluation in surgical oncology. PET is less than optimal for detecting lesions PET-positive lesions can be challenging as a result of difficulties in surgical exposure. We undertook this investigation to assess the utility of a handheld high-energy gamma probe (PET-Probe) for intraoperative identification of 18 F-deoxyglucose (FDG)-avid tumors. Forty patients underwent a diagnostic whole-body FDG-PET scan for consideration for surgical exploration and resection. Before surgery, all patients received an intravenous injection of 7 to 10 mCi of FDG. At surgery, the PET-Probe was used to determine absolute counts per second at the known tumor site(s) demonstrated by whole-body PET and at adjacent normal tissue (at least 4 cm away from tumor-bearing sites). Tumor-to-background ratios were calculated. Thirty-two patients (80%) underwent PET-Probe-guided surgery with therapeutic intent in a recurrent or metastatic disease setting. Eight patients underwent surgery for diagnostic exploration. Anatomical locations of the PET-identified lesions were neck and supraclavicular (n = 8), axilla (n = 5), groin and deep iliac (n = 4), trunk and extremity soft tissue (n = 3), abdominal and retroperitoneal (n = 19), and lung (n = 2). PET-Probe detected all PET-positive lesions. The PET-Probe was instrumental in localization of lesions in 15 patients that were not immediately apparent by surgical exploration. The PET-Probe identified all lesions demonstrated by PET scanning and, in selected cases, was useful in localizing FDG-avid disease not seen with conventional PET scanning.

  14. Technical testing of portable isotope identification instruments

    International Nuclear Information System (INIS)

    Smith, D.E.

    2001-01-01

    Full text: The United States Customs Service has, as a part of its mission, the protection of the borders of the United States from the import or export of illicit radioactive materials. Of paramount importance is the ability to interdict the smuggling of special nuclear material, nuclear weapons and other radioactive materials that could be used as a weapon of mass destruction against the population and infrastructure of the U.S. or another country. Radiation detection technology exists in the form of pocket size, hand-held and portal radiation detectors that have the ability to detect radiation with great sensitivity and low false alarm rates. U.S. Customs has chosen to implement pocket size detectors or radiation pagers as the personal tool of each inspector for the detection of radioactive material. In the search for illicit shipment of radioactive materials, innocent radiation detections may occur with some frequency due to common radioactive sources that may be encountered in day to day living. Examples include lantern mantles, some camera lenses, welding rods, certain dishware containing uranium glaze, and natural marble objects such as statues or architectural pieces. Perhaps the most common innocent detection encountered at the border and in public areas in general is due to the in vivo placement of radioactive sources for use in nuclear medicine therapy and diagnostics. Outpatients from such therapy can remain detectable for three weeks or more. Also, legal shipments of radioisotopes are common occurrences in cargo and express mail shipments. The customs inspector who detects radioactive material in the course of his duties must decide whether detection is innocent; is indicative of a nuclear device or special nuclear material; or whether the source could be injurious to him/her or the general public. It is at this point that a portable instrument capable of identifying gamma or neutron emitting isotopes is essential to the customs examination procedure

  15. Clinical assessment of hip strength using a hand-held dynamometer is reliable

    DEFF Research Database (Denmark)

    Thorborg, K; Petersen, J; Magnusson, S P

    2010-01-01

    rotation (ER), internal rotation (IR), flexion (FLEX) and extension (EXT) using a hand-held dynamometer. Nine subjects (five males, four females), physically active for at least 2.5 h a week, were included. Twelve standardized isometric strength tests were performed twice with a 1-week interval in between......Hip strength assessment plays an important role in the clinical examination of the hip and groin region. The primary aim of this study was to examine the absolute test-retest measurement variation concerning standardized strength assessments of hip abduction (ABD), adduction (ADD), external...... by the same examiner. The test order was randomized to avoid systematic bias. Measurement variation between sessions was 3-12%. When the maximum value of four measurements was used, test-retest measurement variation was below 10% in 11 of the 12 individual hip strength tests and below 5% in five of the 12...

  16. Inter-Tester Reliability and Precision of Manual Muscle Testing and Hand-Held Dynamometry in Lower Limb Muscles of Children with Spina Bifida

    Science.gov (United States)

    Mahony, Kate; Hunt, Adrienne; Daley, Deborah; Sims, Susan; Adams, Roger

    2009-01-01

    Reliability and measurement precision of manual muscle testing (MMT) and hand-held dynamometry (HHD) were compared for children with spina bifida. Strength measures were obtained of the hip flexors, hip abductors, and knee extensors of 20 children (10 males, 10 females; mean age 9 years 10 months; range: 5 to 15 years) by two experienced physical…

  17. Attentionally splitting the mass distribution of hand-held rods.

    Science.gov (United States)

    Burton, G; Turvey, M T

    1991-08-01

    Two experiments on the length-perception capabilities of effortful or dynamic touch differed only in terms of what the subject intended to perceive, while experimental conditions and apparatus were held constant. In each trial, a visually occluded rod was held as still as possible by the subject at an intermediate position. For two thirds of the trials, a weight was attached to the rod above or below the hand. In Experiment 1, in which the subject's task was to perceive the distance reachable with the portion of the rod forward of the hand, perceived extent was a function of the first moment of the mass distribution associated with the forward portion of the rod, and indifferent to the first moment of the entire rod. In Experiment 2, in which the task was to perceive the distance reachable with the entire rod if it was held at an end, the pattern of results was reversed. These results indicate the capability of selective sensitivity to different aspects of a hand-held object's mass distribution, without the possibility of differential exploration specific to these two tasks. Results are discussed in relation to possible roles of differential information, intention, and self-organization in the explanations of selective perceptual abilities.

  18. Mobile Testing of Cognitive Function : A tool for assessment of cognitive abilities in an everyday environment using a handheld device

    OpenAIRE

    Fouchenette, Kim

    2011-01-01

    The unit of Cognitive Developmental Neuroscience at Karolinska Institutet have developed a method for measuring cognitive performance with handheld devices, which resulted in a mobile application for the iPod Touch. The application was previously used in a clinical trial with individuals suffering from chronic stress disorder, but had to be further developed. The application, which consisted of cognitive tests and questionnaires, required improvements that could be divided into three parts: (...

  19. Intrarater reliabilities of shoulder joint horizontal adductor muscle strength measurements using a handheld dynamometer for geriatric and stroke patients

    OpenAIRE

    Hirano, Masahiro; Katoh, Munenori; Kawaguchi, Saori; Uemura, Tomomi

    2016-01-01

    [Purpose] This study aimed to verify the appropriate number of measurements and the intrarater reliabilities of shoulder joint horizontal adductor muscle strength measurements using a handheld dynamometer (HHD) for geriatric and stroke patients. [Subjects and Methods] The subjects were 40 inpatients, who were divided into two groups: 20 stroke patients in the stroke group (SG), and 20 geriatric patients in the no-stroke group (N-SG). Measurements were performed three times using an HHD with a...

  20. Assessment of isometric muscle strength and rate of torque development with hand-held dynamometry: Test-retest reliability and relationship with gait velocity after stroke.

    Science.gov (United States)

    Mentiplay, Benjamin F; Tan, Dawn; Williams, Gavin; Adair, Brooke; Pua, Yong-Hao; Bower, Kelly J; Clark, Ross A

    2018-04-27

    Isometric rate of torque development examines how quickly force can be exerted and may resemble everyday task demands more closely than isometric strength. Rate of torque development may provide further insight into the relationship between muscle function and gait following stroke. Aims of this study were to examine the test-retest reliability of hand-held dynamometry to measure isometric rate of torque development following stroke, to examine associations between strength and rate of torque development, and to compare the relationships of strength and rate of torque development to gait velocity. Sixty-three post-stroke adults participated (60 years, 34 male). Gait velocity was assessed using the fast-paced 10 m walk test. Isometric strength and rate of torque development of seven lower-limb muscle groups were assessed with hand-held dynamometry. Intraclass correlation coefficients were calculated for reliability and Spearman's rho correlations were calculated for associations. Regression analyses using partial F-tests were used to compare strength and rate of torque development in their relationship with gait velocity. Good to excellent reliability was shown for strength and rate of torque development (0.82-0.97). Strong associations were found between strength and rate of torque development (0.71-0.94). Despite high correlations between strength and rate of torque development, rate of torque development failed to provide significant value to regression models that already contained strength. Assessment of isometric rate of torque development with hand-held dynamometry is reliable following stroke, however isometric strength demonstrated greater relationships with gait velocity. Further research should examine the relationship between dynamic measures of muscle strength/torque and gait after stroke. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. A novel fully integrated handheld gamma camera

    International Nuclear Information System (INIS)

    Massari, R.; Ucci, A.; Campisi, C.; Scopinaro, F.; Soluri, A.

    2016-01-01

    In this paper, we present an innovative, fully integrated handheld gamma camera, namely designed to gather in the same device the gamma ray detector with the display and the embedded computing system. The low power consumption allows the prototype to be battery operated. To be useful in radioguided surgery, an intraoperative gamma camera must be very easy to handle since it must be moved to find a suitable view. Consequently, we have developed the first prototype of a fully integrated, compact and lightweight gamma camera for radiopharmaceuticals fast imaging. The device can operate without cables across the sterile field, so it may be easily used in the operating theater for radioguided surgery. The prototype proposed consists of a Silicon Photomultiplier (SiPM) array coupled with a proprietary scintillation structure based on CsI(Tl) crystals. To read the SiPM output signals, we have developed a very low power readout electronics and a dedicated analog to digital conversion system. One of the most critical aspects we faced designing the prototype was the low power consumption, which is mandatory to develop a battery operated device. We have applied this detection device in the lymphoscintigraphy technique (sentinel lymph node mapping) comparing the results obtained with those of a commercial gamma camera (Philips SKYLight). The results obtained confirm a rapid response of the device and an adequate spatial resolution for the use in the scintigraphic imaging. This work confirms the feasibility of a small gamma camera with an integrated display. This device is designed for radioguided surgery and small organ imaging, but it could be easily combined into surgical navigation systems.

  2. A novel fully integrated handheld gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Massari, R.; Ucci, A.; Campisi, C. [Biostructure and Bioimaging Institute (IBB), National Research Council of Italy (CNR), Rome (Italy); Scopinaro, F. [University of Rome “La Sapienza”, S. Andrea Hospital, Rome (Italy); Soluri, A., E-mail: alessandro.soluri@ibb.cnr.it [Biostructure and Bioimaging Institute (IBB), National Research Council of Italy (CNR), Rome (Italy)

    2016-10-01

    In this paper, we present an innovative, fully integrated handheld gamma camera, namely designed to gather in the same device the gamma ray detector with the display and the embedded computing system. The low power consumption allows the prototype to be battery operated. To be useful in radioguided surgery, an intraoperative gamma camera must be very easy to handle since it must be moved to find a suitable view. Consequently, we have developed the first prototype of a fully integrated, compact and lightweight gamma camera for radiopharmaceuticals fast imaging. The device can operate without cables across the sterile field, so it may be easily used in the operating theater for radioguided surgery. The prototype proposed consists of a Silicon Photomultiplier (SiPM) array coupled with a proprietary scintillation structure based on CsI(Tl) crystals. To read the SiPM output signals, we have developed a very low power readout electronics and a dedicated analog to digital conversion system. One of the most critical aspects we faced designing the prototype was the low power consumption, which is mandatory to develop a battery operated device. We have applied this detection device in the lymphoscintigraphy technique (sentinel lymph node mapping) comparing the results obtained with those of a commercial gamma camera (Philips SKYLight). The results obtained confirm a rapid response of the device and an adequate spatial resolution for the use in the scintigraphic imaging. This work confirms the feasibility of a small gamma camera with an integrated display. This device is designed for radioguided surgery and small organ imaging, but it could be easily combined into surgical navigation systems.

  3. Intrasurgical Human Retinal Imaging With Manual Instrument Tracking Using a Microscope-Integrated Spectral-Domain Optical Coherence Tomography Device.

    Science.gov (United States)

    Hahn, Paul; Carrasco-Zevallos, Oscar; Cunefare, David; Migacz, Justin; Farsiu, Sina; Izatt, Joseph A; Toth, Cynthia A

    2015-07-01

    To characterize the first in-human intraoperative imaging using a custom prototype spectral-domain microscope-integrated optical coherence tomography (MIOCT) device during vitreoretinal surgery with instruments in the eye. Under institutional review board approval for a prospective intraoperative study, MIOCT images were obtained at surgical pauses with instruments held static in the vitreous cavity and then concurrently with surgical maneuvers. Postoperatively, MIOCT images obtained at surgical pauses were compared with images obtained with a high-resolution handheld spectral-domain OCT (HHOCT) system with objective endpoints, including acquisition of images acceptable for analysis and identification of predefined macular morphologic or pathologic features. Human MIOCT images were successfully obtained before incision and during pauses in surgical maneuvers. MIOCT imaging confirmed preoperative diagnoses, such as epiretinal membrane, full-thickness macular hole, and vitreomacular traction and demonstrated successful achievement of surgical goals. MIOCT and HHOCT images obtained at surgical pauses in two cohorts of five patients were comparable with greater than or equal to 80% correlation in 80% of patients. Real-time video-imaging concurrent with surgical manipulations enabled, for the first time using this device, visualization of dynamic instrument-retina interaction with targeted OCT tracking. MIOCT is successful for imaging at surgical pauses and for real-time image guidance with implementation of targeted OCT tracking. Even faster acquisition speeds are currently being developed with incorporation of a swept-source MIOCT engine. Further refinements and investigations will be directed toward continued integration for real-time volumetric imaging of surgical maneuvers. Ongoing development of seamless MIOCT systems will likely transform surgical visualization, approaches, and decision-making.

  4. Quantitative evaluation of a handheld light microscope for field diagnosis of soil-transmitted helminth infection.

    Science.gov (United States)

    Bogoch, Isaac I; Andrews, Jason R; Speich, Benjamin; Ame, Shaali M; Ali, Said M; Stothard, J Russell; Utzinger, Jürg; Keiser, Jennifer

    2014-12-01

    We evaluated the Newton Nm1, a commercially available handheld light microscope and compared it with conventional light microscopy for the diagnosis of soil-transmitted helminth infections. A total of 91 Kato-Katz thick smears were examined by experienced microscopists and helminth eggs were counted and expressed as eggs per gram of stool (EPG). Mean egg counts were significantly higher with the conventional light microscope (5,190 EPG versus 2,386 EPG for Ascaris lumbricoides; 826 versus 456 for Trichuris trichiura; both P Newton Nm1 microscope may be a useful tool for the detection and quantification of soil-transmitted helminth infection in clinical, epidemiologic, and public health settings. © The American Society of Tropical Medicine and Hygiene.

  5. Telemedicine and Alzheimer's Disease from Studio-Based Videoconferencing to Mobile Handheld Cell Phones

    Directory of Open Access Journals (Sweden)

    Pk (Poh-Kooi Loh

    2009-01-01

    Full Text Available The use of Telemedicine in the assessment of cognitive impairment and Alzheimer's Disease is evolving with advances in Information and Communication Technology. This article outlines the course of evolution in Western Australia, a large state with a sparse population outside of the capital city. The starting point of the evolution, video-conferencing in Telehealth studios, is reviewed as well as the next stage, use of desktop technology, which enables the physician to consult from the office or clinic. A pilot study currently being undertaken to assess the validity of the latest stage in evolution of Telehealth—the use of handheld mobile cell phone video calling that allows the physician and patient to interact at locations convenient to both parties. The pitfalls and implications of the use of this stage, should it prove to be a valid approach, are discussed.

  6. Digital knowledge in the coat pocket - hand-held personal digital assistants in radiology

    International Nuclear Information System (INIS)

    Niehues, S.M.; Froehlich, M.; Felix, R.; Lemke, A.J.

    2004-01-01

    The personal digital assistant (PDA) enables the independent access to large data in a pocket-sized format. The applications for hand-held computers are growing steadily and can support almost any kind of problem. An overview of the available hardware and software is provided and evaluated. Furthermore, the use of the PDA in the clinical daily routine is described. In view of the numerous software programs available in radiology, the range of software solutions for radiologists is presented. Despite the high acquisition cost, the PDA has already become the digital assistant for the radiologist. After a short time of getting used to the PDA, nobody wants to miss it at work or at home. New technical features and available software programs will continuously increase the integration of the PDA into the medical workflow in the near future. (orig.)

  7. Hand-held Raman sensor head for in-situ characterization of meat quality applying a microsystem 671 nm diode laser

    Science.gov (United States)

    Schmidt, Heinar; Sowoidnich, Kay; Maiwald, Martin; Sumpf, Bernd; Kronfeldt, Heinz-Detlef

    2009-05-01

    A hand-held Raman sensor head was developed for the in-situ characterization of meat quality. As light source, a microsystem based external cavity diode laser module (ECDL) emitting at 671 nm was integrated in the sensor head and attached to a miniaturized optical bench which contains lens optics for excitation and signal collection as well as a Raman filter stage for Rayleigh rejection. The signal is transported with an optical fiber to the detection unit which was in the initial phase a laboratory spectrometer with CCD detector. All elements of the ECDL are aligned on a micro optical bench with 13 x 4 mm2 footprint. The wavelength stability is provided by a reflection Bragg grating and the laser has an optical power of up to 200 mW. However, for the Raman measurements of meat only 35 mW are needed to obtain Raman spectra within 1 - 5 seconds. Short measuring times are essential for the hand-held device. The laser and the sensor head are characterized in terms of stability and performance for in-situ Raman investigations. The function is demonstrated in a series of measurements with raw and packaged pork meat as samples. The suitability of the Raman sensor head for the quality control of meat and other products will be discussed.

  8. Initial Experience with a Handheld Device Digital Imaging and Communications in Medicine Viewer: OsiriX Mobile on the iPhone

    OpenAIRE

    Choudhri, Asim F.; Radvany, Martin G.

    2010-01-01

    Medical imaging is commonly used to diagnose many emergent conditions, as well as plan treatment. Digital images can be reviewed on almost any computing platform. Modern mobile phones and handheld devices are portable computing platforms with robust software programming interfaces, powerful processors, and high-resolution displays. OsiriX mobile, a new Digital Imaging and Communications in Medicine viewing program, is available for the iPhone/iPod touch platform. This raises the possibility o...

  9. Beyond Textbook Illustrations: Hand-Held Models of Ordered DNA and Protein Structures as 3D Supplements to Enhance Student Learning of Helical Biopolymers

    Science.gov (United States)

    Jittivadhna, Karnyupha; Ruenwongsa, Pintip; Panijpan, Bhinyo

    2010-01-01

    Textbook illustrations of 3D biopolymers on printed paper, regardless of how detailed and colorful, suffer from its two-dimensionality. For beginners, computer screen display of skeletal models of biopolymers and their animation usually does not provide the at-a-glance 3D perception and details, which can be done by good hand-held models. Here, we…

  10. Evaluation of Handheld Scanners for Automotive Applications

    Directory of Open Access Journals (Sweden)

    Wadea Ameen

    2018-01-01

    Full Text Available The process of generating a computerized geometric model for an existing part is known as Reverse Engineering (RE. It is a very useful technique in product development and plays a significant role in automotive, aerospace, and medical industries. In fact, it has been getting remarkable attention in manufacturing industries owing to its advanced data acquisition technologies. The process of RE is based on two primary steps: data acquisition (also known as scanning and data processing. To facilitate point data acquisition, a variety of scanning systems is available with different capabilities and limitations. Although the optical control of 3D scanners is fully developed, still several factors can affect the quality of the scanned data. As a result, the proper selection of scanning parameters, such as resolution, laser power, shutter time, etc., becomes very crucial. This kind of investigation can be very helpful and provide its users with guidelines to identify the appropriate factors. Moreover, it is worth noting that no single system is ideal in all applications. Accordingly, this work has compared two portable (handheld systems based on laser scanning and white light optical scanning for automotive applications. A car door containing a free-form surface has been used to achieve the above-mentioned goal. The design of experiments has been employed to determine the effects of different scanning parameters and optimize them. The capabilities and limitations have been identified by comparing the two scanners in terms of accuracy, scanning time, triangle numbers, ease of use, and portability. Then, the relationships between the system capabilities and the application requirements have been established. The results revealed that the laser scanner performed better than the white light scanner in terms of accuracy, while the white light scanner performed better in terms of acquisition speed and triangle numbers.

  11. Digital Waveguide Architectures for Virtual Musical Instruments

    Science.gov (United States)

    Smith, Julius O.

    Digital sound synthesis has become a standard staple of modern music studios, videogames, personal computers, and hand-held devices. As processing power has increased over the years, sound synthesis implementations have evolved from dedicated chip sets, to single-chip solutions, and ultimately to software implementations within processors used primarily for other tasks (such as for graphics or general purpose computing). With the cost of implementation dropping closer and closer to zero, there is increasing room for higher quality algorithms.

  12. Handheld and mobile hyperspectral imaging sensors for wide-area standoff detection of explosives and chemical warfare agents

    Science.gov (United States)

    Gomer, Nathaniel R.; Gardner, Charles W.; Nelson, Matthew P.

    2016-05-01

    Hyperspectral imaging (HSI) is a valuable tool for the investigation and analysis of targets in complex background with a high degree of autonomy. HSI is beneficial for the detection of threat materials on environmental surfaces, where the concentration of the target of interest is often very low and is typically found within complex scenery. Two HSI techniques that have proven to be valuable are Raman and shortwave infrared (SWIR) HSI. Unfortunately, current generation HSI systems have numerous size, weight, and power (SWaP) limitations that make their potential integration onto a handheld or field portable platform difficult. The systems that are field-portable do so by sacrificing system performance, typically by providing an inefficient area search rate, requiring close proximity to the target for screening, and/or eliminating the potential to conduct real-time measurements. To address these shortcomings, ChemImage Sensor Systems (CISS) is developing a variety of wide-field hyperspectral imaging systems. Raman HSI sensors are being developed to overcome two obstacles present in standard Raman detection systems: slow area search rate (due to small laser spot sizes) and lack of eye-safety. SWIR HSI sensors have been integrated into mobile, robot based platforms and handheld variants for the detection of explosives and chemical warfare agents (CWAs). In addition, the fusion of these two technologies into a single system has shown the feasibility of using both techniques concurrently to provide higher probability of detection and lower false alarm rates. This paper will provide background on Raman and SWIR HSI, discuss the applications for these techniques, and provide an overview of novel CISS HSI sensors focused on sensor design and detection results.

  13. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. An inspector-instrument interface design that allows communication of procedures, responses, and results between the instrument and user is presented. This capability has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  14. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. This report describes an inspector-instrument interface design which allows communication of procedures, responses, and results between the instrument and user. The interface has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  15. Hand-held dynamic visual noise reduces naturally occurring food cravings and craving-related consumption.

    Science.gov (United States)

    Kemps, Eva; Tiggemann, Marika

    2013-09-01

    This study demonstrated the applicability of the well-established laboratory task, dynamic visual noise, as a technique for reducing naturally occurring food cravings and subsequent food intake. Dynamic visual noise was delivered on a hand-held computer device. Its effects were assessed within the context of a diary study. Over a 4-week period, 48 undergraduate women recorded their food cravings and consumption. Following a 2-week baseline, half the participants watched the dynamic visual noise display whenever they experienced a food craving. Compared to a control group, these participants reported less intense cravings. They were also less likely to eat following a craving and consequently consumed fewer total calories following craving. These findings hold promise for curbing unwanted food cravings and craving-driven consumption in real-world settings. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. A hand-held 3D laser scanning with global positioning system of subvoxel precision

    International Nuclear Information System (INIS)

    Arias, Nestor; Meneses, Nestor; Meneses, Jaime; Gharbi, Tijani

    2011-01-01

    In this paper we propose a hand-held 3D laser scanner composed of an optical head device to extract 3D local surface information and a stereo vision system with subvoxel precision to measure the position and orientation of the 3D optical head. The optical head is manually scanned over the surface object by the operator. The orientation and position of the 3D optical head is determined by a phase-sensitive method using a 2D regular intensity pattern. This phase reference pattern is rigidly fixed to the optical head and allows their 3D location with subvoxel precision in the observation field of the stereo vision system. The 3D resolution achieved by the stereo vision system is about 33 microns at 1.8 m with an observation field of 60cm x 60cm.

  17. The Complimentary Role of Methoxy-Isobutyl-Isonitrile and Hand-Held Gamma Probe in Adamantinoma

    Science.gov (United States)

    Maharaj, Masha; Korowlay, Nisaar; Ellmann, Prof

    2016-01-01

    Adamantinoma is a rare locally aggressive osteolytic tumor that is found 90% of the time in the diaphysis of the tibia with the remaining lesions found in the fibula and long tubular bones. A case of adamantinoma of the tibia is presented. The added value of nuclear medicine investigations in the workup of this patient is described. A three-phase whole body 99mTc-methylene diphosphonate bone and a whole body 99mTc-methoxy-isobutyl-isonitrile scans were complimentary in the demarcation of viable bone tumor and the assessment of the remainder of the bone and soft tissue to exclude other sites. Intra-operative assistance with a hand-held gamma probe, guided the biopsy of the most metabolically active tumor tissue. Histology revealed a biphasic tumor composed of epithelial and fibrous components, in keeping with an adamantinoma. PMID:26912979

  18. The validity and reliability of the handheld SW-100 autokeratometer

    Directory of Open Access Journals (Sweden)

    Eghosasere Iyamu

    2015-07-01

    Full Text Available Background: The agreement of new instruments or clinical tests with other instruments or tests defines the possibility of these being used interchangeably. Aim: To investigate the validity and reliability of the SW-100 autokeratometer using a Bausch & Lomb (B&L keratometer as the ‘gold standard’. Methods: Eighty subjects (80 right eyes aged between 21 and 38 years were recruited. For intra-test repeatability, two measurements of the corneal radius of curvature were taken with the SW-100 and B&L keratometers. Forty of the 80 subjects participated in the inter-test repeatability measurement. Results: Corneal radius of curvature was found to be statistically different between the two instruments (p < 0.001, with the SW-100 providing slightly flatter values of 0.11 mm and 0.05 mm for the horizontal and vertical meridians, respectively, than the B&L keratometer. The average corneal curvature was 0.07 mm flatter with the SW-100 autokeratometer than with the B&L device. Agreement between the SW-100 and B&L keratometers’ axes was 45% within ± 5°, 60.3% within ± 10°, 78.8% within ± 15°, 80.3% within ± 20°, and 88.7% within ± 40°. Intertest repeatability was better for the B&L device than the SW-100 and showed no significant difference between the two sessions. Both instruments demonstrated comparable intrasession repeatability. As such, both instruments were comparatively reliable (per coefficients of repeatability. The range of limits of agreement of ± 0.14 mm (horizontal meridian and ± 0.17 mm (vertical meridian between the SW-100 and B&L devices showed good agreement. Conclusion: The results suggest that the SW-100 autokeratometer is a reliable and objective instrument that, however, provides flatter radii of curvature measurements than the B&L keratometer. A compensating factor incorporated into the instrument could reduce the difference between the two instruments and make them more interchangeable.

  19. Impact of Alaskan gas subsidy

    International Nuclear Information System (INIS)

    George, R.R.

    2002-01-01

    This report provides the Government of the Northwest Territories (GNWT) with an assessment of the impact of the Alaska natural gas tax credit proposed and passed in the United States Senate energy bill. In particular, Purvin and Gertz evaluated the impact of the Alaskan gas subsidy on potential Mackenzie Delta/Beaufort Sea production as well as existing and future production from other areas including Western Canada, the Rocky Mountains in the United States, and the Gulf Coast. The mechanisms through which other producing areas are affected were described and the typical volumetric impact is presented using gas models developed by Purvin and Gertz. The GNWT wants to maximize the benefits of Arctic gas development for its constituents but believes that its interests will be negatively impacted by subsidized Alaskan gas which will be applied for the period beginning in 2010. The tax credit sets a floor price of $3.25 (US)/MMBtu. Purvin and Gertz concludes that the Alaskan gas subsidy would produce a misallocation of resources and distort the continental North American natural gas market. It would encourage over investment in Alaskan gas production because the credit works as a false signal to the privileged few that divert resources from higher value activities to lower value activities. The winners of the Alaskan gas subsidy would be Alaskan producers and the Alaskan economy. The losers would be other resource owners, producers, and American taxpayers because they would finance the subsidy through a tax credit mechanism. There would be an overall loss to the economy because of sub-optimal allocation of resources. In addition, producers in existing producing areas such as the Mackenzie Delta/Beaufort Sea region would face lower market prices as a result of the subsidy, thereby reducing their investments. It was concluded that the Alaskan gas subsidy is counterproductive from the perspective of a secure continental supply of natural gas. 1 tab., 2 figs

  20. A feasibility and efficacy trial of a hand-held humidification device in patients undergoing radiotherapy for head and neck cancer.

    Science.gov (United States)

    Ghosh, Priyanka; Lazar, Ann A; Ryan, William R; Yom, Sue S

    2017-08-01

    This study aimed to evaluate the effects of warm-mist humidification during and after head and neck radiation therapy (HN RT) on quality of life (QOL), as measured by the M. D. Anderson Symptom Inventory-Head and Neck (MDASI-HN) HN score. A secondary aim was to compare QOL among compliers (≥60% of protocol-recommended usage) versus non-compliers. Twenty patients self-administered a hand-held, self-sterilizing humidification device for a recommended time of at least 15 min twice daily for 12 weeks. Patients completed the MDASI-HN instrument at RT start, after 6 weeks, and after 12 weeks. Compliance was reported weekly. The average HN score at baseline was 1.7 (SD = 1.8) and increased to 6.0 (SD = 1.6) after 6 weeks; this increase was much higher than anticipated and the primary endpoint could not be reached. However, compliers had an average of nearly two less HN symptoms (-1.8, 95% CI -4 to 0.2; p = 0.08) than non-compliers at 6 weeks and fewer symptoms at 12 weeks as well (-0.9, 95% CI -2.9 to 1.2; p = 0.39). The most common terms patients used to describe humidification were "helpful" and "soothing." Compliance with humidification during RT was associated with fewer reported HN symptoms and a strong trend to better QOL. Improvements were seen from compliance with occasional required use of a portable, inexpensive device. Our findings support continued efforts to reduce barriers to humidification, as an intervention that should be considered for standard HN RT clinical practice.

  1. Handheld echocardiography during hospitalization for acute myocardial infarction.

    Science.gov (United States)

    Cullen, Michael W; Geske, Jeffrey B; Anavekar, Nandan S; Askew, J Wells; Lewis, Bradley R; Oh, Jae K

    2017-11-01

    Handheld echocardiography (HHE) is concordant with standard transthoracic echocardiography (TTE) in a variety of settings but has not been thoroughly compared to traditional TTE in patients with acute myocardial infarction (AMI). Completed by experienced operators, HHE provides accurate diagnostic capabilities compared with standard TTE in AMI patients. This study prospectively enrolled patients admitted to the coronary care unit with AMI. Experienced sonographers performed HHE with a V-scan. All patients underwent clinical TTE. Each HHE was interpreted by 2 experts blinded to standard TTE. Agreement was assessed with κ statistics and concordance correlation coefficients. Analysis included 82 patients (mean age, 66 years; 74% male). On standard TTE, mean left ventricular (LV) ejection fraction was 46%. Correlation coefficients between HHE and TTE were 0.75 (95% confidence interval: 0.66 to 0.82) for LV ejection fraction and 0.69 (95% confidence interval: 0.58 to 0.77) for wall motion score index. The κ statistics ranged from 0.47 to 0.56 for LV enlargement, 0.55 to 0.79 for mitral regurgitation, and 0.44 to 0.57 for inferior vena cava dilatation. The κ statistics were highest for the anterior (0.81) and septal (0.71) apex and lowest for the mid inferolateral (0.36) and basal inferoseptal (0.36) walls. In patients with AMI, HHE and standard TTE demonstrate good correlation for LV function and wall motion. Agreement was less robust for structural abnormalities and specific wall segments. In experienced hands, HHE can provide a focused assessment of LV function in patients hospitalized with AMI; however, HHE should not substitute for comprehensive TTE. © 2017 Wiley Periodicals, Inc.

  2. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  3. Into the Wild: Neuroergonomic Differentiation of Hand-Held and Augmented Reality Wearable Displays during Outdoor Navigation with Functional Near Infrared Spectroscopy.

    Science.gov (United States)

    McKendrick, Ryan; Parasuraman, Raja; Murtza, Rabia; Formwalt, Alice; Baccus, Wendy; Paczynski, Martin; Ayaz, Hasan

    2016-01-01

    Highly mobile computing devices promise to improve quality of life, productivity, and performance. Increased situation awareness and reduced mental workload are two potential means by which this can be accomplished. However, it is difficult to measure these concepts in the "wild". We employed ultra-portable battery operated and wireless functional near infrared spectroscopy (fNIRS) to non-invasively measure hemodynamic changes in the brain's Prefrontal cortex (PFC). Measurements were taken during navigation of a college campus with either a hand-held display, or an Augmented reality wearable display (ARWD). Hemodynamic measures were also paired with secondary tasks of visual perception and auditory working memory to provide behavioral assessment of situation awareness and mental workload. Navigating with an augmented reality wearable display produced the least workload during the auditory working memory task, and a trend for improved situation awareness in our measures of prefrontal hemodynamics. The hemodynamics associated with errors were also different between the two devices. Errors with an augmented reality wearable display were associated with increased prefrontal activity and the opposite was observed for the hand-held display. This suggests that the cognitive mechanisms underlying errors between the two devices differ. These findings show fNIRS is a valuable tool for assessing new technology in ecologically valid settings and that ARWDs offer benefits with regards to mental workload while navigating, and potentially superior situation awareness with improved display design.

  4. Technology Roadmap Instrumentation, Control, and Human-Machine Interface to Support DOE Advanced Nuclear Energy Programs

    Energy Technology Data Exchange (ETDEWEB)

    Donald D Dudenhoeffer; Burce P Hallbert

    2007-03-01

    Instrumentation, Controls, and Human-Machine Interface (ICHMI) technologies are essential to ensuring delivery and effective operation of optimized advanced Generation IV (Gen IV) nuclear energy systems. In 1996, the Watts Bar I nuclear power plant in Tennessee was the last U.S. nuclear power plant to go on line. It was, in fact, built based on pre-1990 technology. Since this last U.S. nuclear power plant was designed, there have been major advances in the field of ICHMI systems. Computer technology employed in other industries has advanced dramatically, and computing systems are now replaced every few years as they become functionally obsolete. Functional obsolescence occurs when newer, more functional technology replaces or supersedes an existing technology, even though an existing technology may well be in working order.Although ICHMI architectures are comprised of much of the same technology, they have not been updated nearly as often in the nuclear power industry. For example, some newer Personal Digital Assistants (PDAs) or handheld computers may, in fact, have more functionality than the 1996 computer control system at the Watts Bar I plant. This illustrates the need to transition and upgrade current nuclear power plant ICHMI technologies.

  5. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  6. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  7. Seismic refraction profile, Kingdom of Saudi Arabia: field operations, instrumentation, and initial results

    Science.gov (United States)

    Blank, H. Richard; Healy, J.H.; Roller, John; Lamson, Ralph; Fisher, Fred; McClearn, Robert; Allen, Steve

    1979-01-01

    In February 1978 a seismic deep-refraction profile was recorded by the USGS along a 1000-km line across the Arabian Shield in western Saudi Arabia. The line begins in Paleozoic and Mesozoic cover rocks near Riyadh on the Arabian Platform, leads southwesterly across three major Precambrian tectonic provinces, traverses Cenozoic rocks of the coastal plain near Jizan (Tihamat Asir), and terminates at the outer edge of the Farasan Bank in the southern Red Sea. More than 500 surveyed recording sites were occupied, including 19 in the Farasan Islands. Six shot points were used--five on land, with charges placed mostly below water table in drill holes, and one at sea, with charges placed on the sea floor and fired from a ship. The total charge consumed was slightly in excess of 61 metric tons in 21 discrete firings. Seismic energy was recorded by means of a set of 100 newly developed portable seismic stations. Each station consists of a standard 2-Hz vertical geophone coupled to a self-contained analog recording instrument equipped with a magnetic-tape cassette. The stations were deployed in groups of 20 by five observer teams, each generally consisting of two scientist-technicians and a surveyor-guide. On the day prior to deployment, the instruments were calibrated and programmed for automatic operation by means of a specially designed device called a hand-held tester. At each of ten pre-selected recording time windows on a designated firing day, the instruments were programmed to turn on, stabilize, record internal calibration signals, record the seismic signals at three levels of amplification, and then deactivate. After the final window in the firing sequence, all instruments were retrieved and their data tapes removed for processing. A specially designed, field tape- dubbing system was utilized at shot point camps to organize and edit data recorded on the cassette tapes. The main functions of this system are to concatenate all data from each shot on any given day

  8. Elemental Analysis of Bone, Teeth, Horn and Antler in Different Animal Species Using Non-Invasive Handheld X-Ray Fluorescence

    Science.gov (United States)

    Buddhachat, Kittisak; Klinhom, Sarisa; Siengdee, Puntita; Brown, Janine L.; Nomsiri, Raksiri; Kaewmong, Patcharaporn; Thitaram, Chatchote; Mahakkanukrauh, Pasuk; Nganvongpanit, Korakot

    2016-01-01

    Mineralized tissues accumulate elements that play crucial roles in animal health. Although elemental content of bone, blood and teeth of human and some animal species have been characterized, data for many others are lacking, as well as species comparisons. Here we describe the distribution of elements in horn (Bovidae), antler (Cervidae), teeth and bone (humerus) across a number of species determined by handheld X-ray fluorescence (XRF) to better understand differences and potential biological relevance. A difference in elemental profiles between horns and antlers was observed, possibly due to the outer layer of horns being comprised of keratin, whereas antlers are true bone. Species differences in tissue elemental content may be intrinsic, but also related to feeding habits that contribute to mineral accumulation, particularly for toxic heavy metals. One significant finding was a higher level of iron (Fe) in the humerus bone of elephants compared to other species. This may be an adaptation of the hematopoietic system by distributing Fe throughout the bone rather than the marrow, as elephant humerus lacks a marrow cavity. We also conducted discriminant analysis and found XRF was capable of distinguishing samples from different species, with humerus bone being the best source for species discrimination. For example, we found a 79.2% correct prediction and success rate of 80% for classification between human and non-human humerus bone. These findings show that handheld XRF can serve as an effective tool for the biological study of elemental composition in mineralized tissue samples and may have a forensic application. PMID:27196603

  9. Elemental Analysis of Bone, Teeth, Horn and Antler in Different Animal Species Using Non-Invasive Handheld X-Ray Fluorescence.

    Directory of Open Access Journals (Sweden)

    Kittisak Buddhachat

    Full Text Available Mineralized tissues accumulate elements that play crucial roles in animal health. Although elemental content of bone, blood and teeth of human and some animal species have been characterized, data for many others are lacking, as well as species comparisons. Here we describe the distribution of elements in horn (Bovidae, antler (Cervidae, teeth and bone (humerus across a number of species determined by handheld X-ray fluorescence (XRF to better understand differences and potential biological relevance. A difference in elemental profiles between horns and antlers was observed, possibly due to the outer layer of horns being comprised of keratin, whereas antlers are true bone. Species differences in tissue elemental content may be intrinsic, but also related to feeding habits that contribute to mineral accumulation, particularly for toxic heavy metals. One significant finding was a higher level of iron (Fe in the humerus bone of elephants compared to other species. This may be an adaptation of the hematopoietic system by distributing Fe throughout the bone rather than the marrow, as elephant humerus lacks a marrow cavity. We also conducted discriminant analysis and found XRF was capable of distinguishing samples from different species, with humerus bone being the best source for species discrimination. For example, we found a 79.2% correct prediction and success rate of 80% for classification between human and non-human humerus bone. These findings show that handheld XRF can serve as an effective tool for the biological study of elemental composition in mineralized tissue samples and may have a forensic application.

  10. Elemental Analysis of Bone, Teeth, Horn and Antler in Different Animal Species Using Non-Invasive Handheld X-Ray Fluorescence.

    Science.gov (United States)

    Buddhachat, Kittisak; Klinhom, Sarisa; Siengdee, Puntita; Brown, Janine L; Nomsiri, Raksiri; Kaewmong, Patcharaporn; Thitaram, Chatchote; Mahakkanukrauh, Pasuk; Nganvongpanit, Korakot

    2016-01-01

    Mineralized tissues accumulate elements that play crucial roles in animal health. Although elemental content of bone, blood and teeth of human and some animal species have been characterized, data for many others are lacking, as well as species comparisons. Here we describe the distribution of elements in horn (Bovidae), antler (Cervidae), teeth and bone (humerus) across a number of species determined by handheld X-ray fluorescence (XRF) to better understand differences and potential biological relevance. A difference in elemental profiles between horns and antlers was observed, possibly due to the outer layer of horns being comprised of keratin, whereas antlers are true bone. Species differences in tissue elemental content may be intrinsic, but also related to feeding habits that contribute to mineral accumulation, particularly for toxic heavy metals. One significant finding was a higher level of iron (Fe) in the humerus bone of elephants compared to other species. This may be an adaptation of the hematopoietic system by distributing Fe throughout the bone rather than the marrow, as elephant humerus lacks a marrow cavity. We also conducted discriminant analysis and found XRF was capable of distinguishing samples from different species, with humerus bone being the best source for species discrimination. For example, we found a 79.2% correct prediction and success rate of 80% for classification between human and non-human humerus bone. These findings show that handheld XRF can serve as an effective tool for the biological study of elemental composition in mineralized tissue samples and may have a forensic application.

  11. Calculation of induced current densities and specific absorption rates (SAR) for pregnant women exposed to hand-held metal detectors

    International Nuclear Information System (INIS)

    Kainz, Wolfgang; Chan, Dulciana D; Casamento, Jon P; Bassen, Howard I

    2003-01-01

    The finite difference time domain (FDTD) method in combination with a well established frequency scaling method was used to calculate the internal fields and current densities induced in a simple model of a pregnant woman and her foetus, when exposed to hand-held metal detectors. The pregnant woman and foetus were modelled using a simple semi-heterogeneous model in 10 mm resolution, consisting of three different types of tissue. The model is based on the scanned shape of a pregnant woman in the 34th gestational week. Nine different representative models of hand-held metal detectors operating in the frequency range from 8 kHz to 2 MHz were evaluated. The metal detectors were placed directly on the abdomen of the computational model with a spacing of 1 cm. Both the induced current density and the specific absorption rate (SAR) are well below the recommended limits for exposure of the general public published in the ICNIRP Guidelines and the IEEE C95.1 Standard. The highest current density is 8.3 mA m -2 and the highest SAR is 26.5 μW kg -1 . Compared to the limits for the induced current density recommended in the ICNIRP Guidelines, a minimum safety factor of 3 exists. Compared to the IEEE C95.1 Standard, a safety factor of 60,000 for the specific absorption rate was found. Based on the very low specific absorption rate and an induced current density below the recommended exposure limits, significant temperature rise or nerve stimulation in the pregnant woman or in the foetus can be excluded

  12. Hand-held multi-DOF robotic forceps for neurosurgery designed for dexterous manipulation in deep and narrow space.

    Science.gov (United States)

    Okubo, Takuro; Harada, Kanako; Fujii, Masahiro; Tanaka, Shinichi; Ishimaru, Tetsuya; Iwanaka, Tadashi; Nakatomi, Hirohumi; Sora, Sigeo; Morita, Akio; Sugita, Naohiko; Mitsuishi, Mamoru

    2014-01-01

    Neurosurgical procedures require precise and dexterous manipulation of a surgical suture in narrow and deep spaces in the brain. This is necessary for surgical tasks such as the anastomosis of microscopic blood vessels and dura mater suturing. A hand-held multi-degree of freedom (DOF) robotic forceps was developed to aid the performance of such difficult tasks. The diameter of the developed robotic forceps is 3.5 mm, and its tip has three DOFs, namely, bending, rotation, and grip. Experimental results showed that the robotic forceps had an average needle insertion force of 1.7 N. Therefore, an increase in the needle insertion force is necessary for practical application of the developed device.

  13. Characterization of wood dust emission from hand-held woodworking machines.

    Science.gov (United States)

    Keller, F-X; Chata, F

    2018-01-01

    This article focuses on the prevention of exposure to wood dust when operating electrical hand-held sawing and sanding machines. A laboratory methodology was developed to measure the dust concentration around machines during operating processes. The main objective was to characterize circular saws and sanders, with the aim of classifying the different power tools tested in terms of dust emission (high dust emitter vs. low dust emitter). A test set-up was developed and is described and a measurement methodology was determined for each of the two operations studied. The robustness of the experimental results is discussed and shows good tendencies. The impact of air-flow extraction rate was assessed and the pressure loss of the system for each machine established. For the circular saws, three machines over the nine tested could be classified in the low dust emitter group. Their mean concentration values measured are between 0.64 and 0.98 mg/m 3 for the low dust emitter group and from 2.55 and 4.37 mg/m 3 for the high dust emitter group. From concentration measurements, a machine classification is possible-one for sanding machines and one for sawing machines-and a ratio from 1-7 is obtained when comparing the results. This classification will be helpful when a choice of high performance power tools, in terms of dust emission, must be made by professionals.

  14. Accuracy of Mobile Phone and Handheld Light Microscopy for the Diagnosis of Schistosomiasis and Intestinal Protozoa Infections in Côte d'Ivoire.

    Directory of Open Access Journals (Sweden)

    Jean T Coulibaly

    2016-06-01

    Full Text Available Handheld light microscopy using compact optics and mobile phones may improve the quality of health care in resource-constrained settings by enabling access to prompt and accurate diagnosis.Laboratory technicians were trained to operate two handheld diagnostic devices (Newton Nm1 microscope and a clip-on version of the mobile phone-based CellScope. The accuracy of these devices was compared to conventional light microscopy for the diagnosis of Schistosoma haematobium, S. mansoni, and intestinal protozoa infection in a community-based survey in rural Côte d'Ivoire. One slide of 10 ml filtered urine and a single Kato-Katz thick smear from 226 individuals were subjected to the Newton Nm1 microscope and CellScope for detection of Schistosoma eggs and compared to conventional microscopy. Additionally, 121 sodium acetate-acetic acid-formalin (SAF-fixed stool samples were examined by the Newton Nm1 microscope and compared to conventional microscopy for the diagnosis of intestinal protozoa.The prevalence of S. haematobium, S. mansoni, Giardia intestinalis, and Entamoeba histolytica/E. dispar, as determined by conventional microscopy, was 39.8%, 5.3%, 20.7%, and 4.9%, respectively. The Newton Nm1 microscope had diagnostic sensitivities for S. mansoni and S. haematobium infection of 91.7% (95% confidence interval (CI 59.8-99.6% and 81.1% (95% CI 71.2-88.3%, respectively, and specificities of 99.5% (95% CI 97.0-100% and 97.1% (95% CI 92.2-99.1%, respectively. The CellScope demonstrated sensitivities for S. mansoni and S. haematobium of 50.0% (95% CI 25.4-74.6% and 35.6% (95% CI 25.9-46.4%, respectively, and specificities of 99.5% (95% CI 97.0-100% and 100% (95% CI 86.7-100%, respectively. For G. intestinalis and E. histolytica/E. dispar, the Newton Nm1 microscope had sensitivity of 84.0% (95% CI 63.1-94.7% and 83.3% (95% CI 36.5-99.1%, respectively, and 100% specificity.Handheld diagnostic devices can be employed in community-based surveys in resource

  15. Accuracy of Mobile Phone and Handheld Light Microscopy for the Diagnosis of Schistosomiasis and Intestinal Protozoa Infections in Côte d'Ivoire.

    Science.gov (United States)

    Coulibaly, Jean T; Ouattara, Mamadou; D'Ambrosio, Michael V; Fletcher, Daniel A; Keiser, Jennifer; Utzinger, Jürg; N'Goran, Eliézer K; Andrews, Jason R; Bogoch, Isaac I

    2016-06-01

    Handheld light microscopy using compact optics and mobile phones may improve the quality of health care in resource-constrained settings by enabling access to prompt and accurate diagnosis. Laboratory technicians were trained to operate two handheld diagnostic devices (Newton Nm1 microscope and a clip-on version of the mobile phone-based CellScope). The accuracy of these devices was compared to conventional light microscopy for the diagnosis of Schistosoma haematobium, S. mansoni, and intestinal protozoa infection in a community-based survey in rural Côte d'Ivoire. One slide of 10 ml filtered urine and a single Kato-Katz thick smear from 226 individuals were subjected to the Newton Nm1 microscope and CellScope for detection of Schistosoma eggs and compared to conventional microscopy. Additionally, 121 sodium acetate-acetic acid-formalin (SAF)-fixed stool samples were examined by the Newton Nm1 microscope and compared to conventional microscopy for the diagnosis of intestinal protozoa. The prevalence of S. haematobium, S. mansoni, Giardia intestinalis, and Entamoeba histolytica/E. dispar, as determined by conventional microscopy, was 39.8%, 5.3%, 20.7%, and 4.9%, respectively. The Newton Nm1 microscope had diagnostic sensitivities for S. mansoni and S. haematobium infection of 91.7% (95% confidence interval (CI) 59.8-99.6%) and 81.1% (95% CI 71.2-88.3%), respectively, and specificities of 99.5% (95% CI 97.0-100%) and 97.1% (95% CI 92.2-99.1%), respectively. The CellScope demonstrated sensitivities for S. mansoni and S. haematobium of 50.0% (95% CI 25.4-74.6%) and 35.6% (95% CI 25.9-46.4%), respectively, and specificities of 99.5% (95% CI 97.0-100%) and 100% (95% CI 86.7-100%), respectively. For G. intestinalis and E. histolytica/E. dispar, the Newton Nm1 microscope had sensitivity of 84.0% (95% CI 63.1-94.7%) and 83.3% (95% CI 36.5-99.1%), respectively, and 100% specificity. Handheld diagnostic devices can be employed in community-based surveys in resource

  16. Geochemical mapping in polluted floodplains using handheld XRF, geophysical imaging, and geostatistics

    Science.gov (United States)

    Hošek, Michal; Matys Grygar, Tomáš; Popelka, Jan; Kiss, Timea; Elznicová, Jitka; Faměra, Martin

    2017-04-01

    In the recent years researchers have enjoyed noticeable improvements of portable analytical and geophysical methods, which allow studying floodplain architecture and deciphering pollutant distribution more easily than ever before. Our area of interest was floodplain of the Ploučnice River, particularly a pollution hotspot in Boreček, severely impacted by U mining between the 1970s and late 1980s, in particular a "radioactive flood" in 1981. In the area, we used hand drill coring and in situ (field) analysis of so acquired sediments by handheld X-ray fluorescence spectrometer (XRF), which gave us information about depth profiles of pollutants (Ba, U, Zn) and the Al/Si and Zr/Rb ratios, i.e., proxies for sediment lithology. We found that spatial distribution of pollutants (control by depth and position in the floodplain) is apparently complex and discontinuous. In some places, contamination is buried by a couple decimetres of less polluted sediments, while in other places the peak pollution is near surface, apparently without a straightforward connection with the surface topography and the distance to the river channel. We thus examined the floodplain architecture, the internal structure of the floodplain using two geophysical methods. First of them, dipole electromagnetic profiling (DEMP, also denoted EMP, MP, or Slingram) quickly acquires average electric resistivity in top strata in selected areas, which was actually top 3 m with our particular instrument. Second, electric resistivity tomography (ERT) produces much more detailed information on resistivity with depth resolution of ca 0.5 m to the depth of ca 5 m in selected lines. ERT thus allows identifying boundaries of electric resistivity domains (sediment bodies) and DEMP their spatial distribution. Based on the obtained data, we divided the floodplain to five segments with specific topography, pollution characteristics, and electric resistivity. We suppose that those segments are lithogenetic floodplain

  17. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  18. Technology Roadmap on Instrumentation, Control, and Human-Machine Interface to Support DOE Advanced Nuclear Energy Programs

    International Nuclear Information System (INIS)

    Donald D Dudenhoeffer; Burce P Hallbert

    2007-01-01

    Instrumentation, Controls, and Human-Machine Interface (ICHMI) technologies are essential to ensuring delivery and effective operation of optimized advanced Generation IV (Gen IV) nuclear energy systems. In 1996, the Watts Bar I nuclear power plant in Tennessee was the last U.S. nuclear power plant to go on line. It was, in fact, built based on pre-1990 technology. Since this last U.S. nuclear power plant was designed, there have been major advances in the field of ICHMI systems. Computer technology employed in other industries has advanced dramatically, and computing systems are now replaced every few years as they become functionally obsolete. Functional obsolescence occurs when newer, more functional technology replaces or supersedes an existing technology, even though an existing technology may well be in working order. Although ICHMI architectures are comprised of much of the same technology, they have not been updated nearly as often in the nuclear power industry. For example, some newer Personal Digital Assistants (PDAs) or handheld computers may, in fact, have more functionality than the 1996 computer control system at the Watts Bar I plant. This illustrates the need to transition and upgrade current nuclear power plant ICHMI technologies

  19. Hazardous metals in vintage plastic toys measured by a handheld X-ray fluorescence spectrometer.

    Science.gov (United States)

    Miller, Gillian Zaharias; Harris, Zoe E

    2015-01-01

    Over 100 plastic toys from the 1970s and 1980s, both polyvinyl chloride ("vinyl") and nonvinyl, were analyzed in the study described here using a handheld X-ray fluorescence spectrometer to quantify hazardous metal content. A sampling of recent vinyl toys was also tested. The majority of nonvinyl samples were Fisher Price brand toys. The vinyl toys consisted largely of Barbie dolls and other dolls. Overall, lead or cadmium was found in 67% of vintage plastic toys, frequently at concentrations exceeding current U.S. and European limits. Arsenic was detected at levels of concern in 16% of the samples. In the nonvinyl toys, heavy metal content was found to correlate with certain colors of plastic. The likely sources of the detected metals are discussed. None of the contemporary vinyl toys contained detectable cadmium, lead, or arsenic. Given that vintage toys remain in widespread use by children in homes and other locations, the results illuminate a potential source of heavy metal exposure for children.

  20. Instrument Remote Control via the Astronomical Instrument Markup Language

    Science.gov (United States)

    Sall, Ken; Ames, Troy; Warsaw, Craig; Koons, Lisa; Shafer, Richard

    1998-01-01

    The Instrument Remote Control (IRC) project ongoing at NASA's Goddard Space Flight Center's (GSFC) Information Systems Center (ISC) supports NASA's mission by defining an adaptive intranet-based framework that provides robust interactive and distributed control and monitoring of remote instruments. An astronomical IRC architecture that combines the platform-independent processing capabilities of Java with the power of Extensible Markup Language (XML) to express hierarchical data in an equally platform-independent, as well as human readable manner, has been developed. This architecture is implemented using a variety of XML support tools and Application Programming Interfaces (API) written in Java. IRC will enable trusted astronomers from around the world to easily access infrared instruments (e.g., telescopes, cameras, and spectrometers) located in remote, inhospitable environments, such as the South Pole, a high Chilean mountaintop, or an airborne observatory aboard a Boeing 747. Using IRC's frameworks, an astronomer or other scientist can easily define the type of onboard instrument, control the instrument remotely, and return monitoring data all through the intranet. The Astronomical Instrument Markup Language (AIML) is the first implementation of the more general Instrument Markup Language (IML). The key aspects of our approach to instrument description and control applies to many domains, from medical instruments to machine assembly lines. The concepts behind AIML apply equally well to the description and control of instruments in general. IRC enables us to apply our techniques to several instruments, preferably from different observatories.

  1. Technical Basis for Implementation of the PCM-1B for Personnel Release at Tank Farms

    International Nuclear Information System (INIS)

    BROWN, R.L.

    1999-01-01

    The purpose of this document is to define the technical basis and implementing guidelines for using automated personnel contamination monitors, such as the PCM-1B, at the River Protection Project (RPP) in lieu of performing a hand-held instrument followed by a PCM-1B survey for personnel release from contamination areas requiring a beta-gamma whole body survey. This document provides the basis for full implementation of the PCM-1B release survey, without the supplemental hand and foot survey, as currently implemented at RPP. This document applies only to RPP facilities. This document does not provide the technical basis for determining the equivalency of an automated system to hand-held instruments, or to the effective counting capability of automated systems as such technical determinations are contained in TBTN: GDGH-9604-RLS-0015

  2. Pre-test habituation improves the reliability of a handheld test of mechanical nociceptive threshold in dairy cows

    DEFF Research Database (Denmark)

    Raundal, P. M.; Andersen, P. H.; Toft, Nils

    2015-01-01

    Mechanical nociceptive threshold (MNT) testing has been used to investigate aspects of painful states in bovine claws. We investigated a handheld tool, where the applied stimulation force was monitored continuously relative to a pre-encoded based target force. The effect on MNT of two pre-testing...... habituation procedures was performed in two different experiments comprising a total of 88 sound Holsteins dairy cows kept either inside or outside their home environment. MNT testing was performed using five consecutive mechanical nociceptive stimulations per cow per test at a fixed pre-encoded target rate...... of 2.1 N/s. The habituation procedure performed in dairy cows kept in their home environment led to lowered intra-individual coefficient of variation of MNT (P test...

  3. Development and characterization of a handheld hyperspectral Raman imaging probe system for molecular characterization of tissue on mesoscopic scales.

    Science.gov (United States)

    St-Arnaud, Karl; Aubertin, Kelly; Strupler, Mathias; Madore, Wendy-Julie; Grosset, Andrée-Anne; Petrecca, Kevin; Trudel, Dominique; Leblond, Frédéric

    2018-01-01

    Raman spectroscopy is a promising cancer detection technique for surgical guidance applications. It can provide quantitative information relating to global tissue properties associated with structural, metabolic, immunological, and genetic biochemical phenomena in terms of molecular species including amino acids, lipids, proteins, and nucleic acid (DNA). To date in vivo Raman spectroscopy systems mostly included probes and biopsy needles typically limited to single-point tissue interrogation over a scale between 100 and 500 microns. The development of wider field handheld systems could improve tumor localization for a range of open surgery applications including brain, ovarian, and skin cancers. Here we present a novel Raman spectroscopy implementation using a coherent imaging bundle of fibers to create a probe capable of reconstructing molecular images over mesoscopic fields of view. Detection is performed using linear scanning with a rotation mirror and an imaging spectrometer. Different slits widths were tested at the entrance of the spectrometer to optimize spatial and spectral resolution while preserving sufficient signal-to-noise ratios to detect the principal Raman tissue features. The nonbiological samples, calcite and polytetrafluoroethylene (PTFE), were used to characterize the performance of the system. The new wide-field probe was tested on ex vivo samples of calf brain and swine tissue. Raman spectral content of both tissue types were validated with data from the literature and compared with data acquired with a single-point Raman spectroscopy probe. The single-point probe was used as the gold standard against which the new instrument was benchmarked as it has already been thoroughly validated for biological tissue characterization. We have developed and characterized a practical noncontact handheld Raman imager providing tissue information at a spatial resolution of 115 microns over a field of view >14 mm 2 and a spectral resolution of 6 cm -1 over

  4. Field-Portable Immunoassay Instruments and Reagents to Measure Chelators and Mobile Forms of Uranium

    International Nuclear Information System (INIS)

    Blake, Diane A.

    2003-01-01

    The goals for the 3-year project period are (1) to test and validate the present uranium sensor and develop protocols for its use at the NABIR Field Research Center; (2) to develop new reagents that will provide superior performance for the present hand-held immunosensor; and (3) to develop new antibodies that will permit this sensor to also measure other environmental contaminants (chromium, mercury, and/or DTPA). Sensor design modifications are underway via international collaborations. New reagents that will provide superior performance for the present hand-held immunosensor are being prepared and tested. New methods have been developed, to produce recombinant forms of metal-specific monoclonal antibodies for use with the sensor. Site-directed mutagenesis experiments are underway to determine the mechanisms of binding. Immunization experiments with sheep and rabbits to develop new recombinant forms of antibodies to metal-chelate complexes (chromium, mercury, and/or DTPA) have been initiated

  5. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  6. Duplication of complete dentures using general-purpose handheld optical scanner and 3-dimensional printer: Introduction and clinical considerations.

    Science.gov (United States)

    Kurahashi, Kosuke; Matsuda, Takashi; Goto, Takaharu; Ishida, Yuichi; Ito, Teruaki; Ichikawa, Tetsuo

    2017-01-01

    To introduce a new clinical procedure for fabricating duplicates of complete dentures by bite pressure impression using digital technology, and to discuss its clinical significance. The denture is placed on a rotary table and the 3-dimensional form of the denture is digitized using a general-purpose handheld optical scanner. The duplicate denture is made of polylactic acid by a 3-dimensional printer using the 3-dimensional data. This procedure has the advantages of wasting less material, employing less human power, decreasing treatment time at the chair side, lowering the rates of contamination, and being readily fabricated at the time of the treatment visit. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  7. Initial experience with a handheld device digital imaging and communications in medicine viewer: OsiriX mobile on the iPhone.

    Science.gov (United States)

    Choudhri, Asim F; Radvany, Martin G

    2011-04-01

    Medical imaging is commonly used to diagnose many emergent conditions, as well as plan treatment. Digital images can be reviewed on almost any computing platform. Modern mobile phones and handheld devices are portable computing platforms with robust software programming interfaces, powerful processors, and high-resolution displays. OsiriX mobile, a new Digital Imaging and Communications in Medicine viewing program, is available for the iPhone/iPod touch platform. This raises the possibility of mobile review of diagnostic medical images to expedite diagnosis and treatment planning using a commercial off the shelf solution, facilitating communication among radiologists and referring clinicians.

  8. A handheld low temperature atmospheric pressure air plasma gun for nanomaterial synthesis in liquid phase

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Shuang; Wang, Kaile; Zuo, Shasha; Liu, Jiahui [Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871 (China); Zhang, Jue, E-mail: zhangjue@pku.edu.cn; Fang, Jing [Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871 (China); College of Engineering, Peking University, Beijing 100871 (China)

    2015-10-15

    A handheld low temperature atmospheric pressure air plasma gun based on a dielectric barrier structure with hollow electrodes was proposed. The portable plasma gun with an embedded mini air pump was driven by a 12 V direct voltage battery. The air plasma jet generated from the gun could be touched without a common shock hazard. Besides working in air, the plasma gun can also work in water. The diagnostic result of optical emission spectroscopy showed the difference in reactive species of air plasma jet between in air and in water. The plasma gun was excited in 20 ml chloroauric acid aqueous solution with a concentration of 1.214 mM. A significant amount of gold nanoparticles were synthesized after 2 min continuous discharge. The plasma gun with these unique features is applicable in plasma medicine, etching, and s-nthesis of nanomaterials.

  9. Mobile applications for handheld devices to screen and randomize acute stroke patients in clinical trials.

    Science.gov (United States)

    Qureshi, Ai; Connelly, B; Abbott, Ei; Maland, E; Kim, J; Blake, J

    2012-08-01

    The availability of internet connectivity and mobile application software used by low-power handheld devices makes smart phones of unique value in time-sensitive clinical trials. Trial-specific applications can be downloaded by investigators from various mobile software distribution platforms or web applications delivered over HTTP. The Antihypertensive Treatment in Acute Cerebral Hemorrhage (ATACH) II investigators in collaboration with MentorMate released the ATACH-II Patient Recruitment mobile application available on iPhone, Android, and Blackberry in 2011. The mobile application provides tools for pre-screening, assessment of eligibility, and randomization of patients. Since the release of ATACH-II mobile application, the CLEAR-IVH (Clot Lysis Evaluating Accelerated Resolution of Intraventricular Hemorrhage) trial investigators have also adopted such a mobile application. The video-conferencing capabilities of the most recent mobile devices open up additional opportunities to involve central coordinating centers in the recruitment process in real time.

  10. Robust sleep quality quantification method for a personal handheld device.

    Science.gov (United States)

    Shin, Hangsik; Choi, Byunghun; Kim, Doyoon; Cho, Jaegeol

    2014-06-01

    The purpose of this study was to develop and validate a novel method for sleep quality quantification using personal handheld devices. The proposed method used 3- or 6-axes signals, including acceleration and angular velocity, obtained from built-in sensors in a smartphone and applied a real-time wavelet denoising technique to minimize the nonstationary noise. Sleep or wake status was decided on each axis, and the totals were finally summed to calculate sleep efficiency (SE), regarded as sleep quality in general. The sleep experiment was carried out for performance evaluation of the proposed method, and 14 subjects participated. An experimental protocol was designed for comparative analysis. The activity during sleep was recorded not only by the proposed method but also by well-known commercial applications simultaneously; moreover, activity was recorded on different mattresses and locations to verify the reliability in practical use. Every calculated SE was compared with the SE of a clinically certified medical device, the Philips (Amsterdam, The Netherlands) Actiwatch. In these experiments, the proposed method proved its reliability in quantifying sleep quality. Compared with the Actiwatch, accuracy and average bias error of SE calculated by the proposed method were 96.50% and -1.91%, respectively. The proposed method was vastly superior to other comparative applications with at least 11.41% in average accuracy and at least 6.10% in average bias; average accuracy and average absolute bias error of comparative applications were 76.33% and 17.52%, respectively.

  11. Thresholds of whole-blood β-hydroxybutyrate and glucose concentrations measured with an electronic hand-held device to identify ovine hyperketonemia.

    Science.gov (United States)

    Pichler, M; Damberger, A; Schwendenwein, I; Gasteiner, J; Drillich, M; Iwersen, M

    2014-03-01

    Metabolic disorders, especially hyperketonemia, are very common in dairy sheep. The whole-blood concentrations of β-hydroxybutyrate (BHBA) and glucose can be determined by commercially available electronic hand-held devices, which are used in human medicine and for the detection of ketosis in dairy cows. The aim of this study was to evaluate the suitability of the hand-held device Precision Xceed (PX; Abbott Diabetes Care Inc., Abbott Park, IL) to detect hyperketonemia in ewes. An additional objective of this study was to evaluate the agreement between samples obtained by minimal invasive venipuncture of an ear vein and measurements of whole-blood samples from the jugular vein (vena jugularis, v. jug.). Blood samples taken from the v. jug. were collected from 358 ewes on 4 different farms. These samples and a blood drop obtained from an ear vein were analyzed simultaneously on farm with the PX. For method comparison, the samples obtained from the v. jug. were also analyzed by standard methods, which served as the gold standard at the Central Laboratory of the University of Veterinary Medicine Vienna, Austria. The correlation coefficients between the serum BHBA concentration and the concentrations measured with the hand-held meter in the whole blood from an ear vein and the v. jug. were 0.94 and 0.96, respectively. The correlation coefficients of plasma and whole-blood glucose concentration were 0.68 for the v. jug. and 0.47 for the ear vein. The mean glucose concentration was significantly lower in animals classified as hyperketonemic (BHBA ≥ 1.6 mmol/L) compared with healthy ewes. Whole-blood concentrations of BHBA and glucose measured with the PX from v. jug. showed a constant negative bias of 0.15 mmol/L and 8.4 mg/dL, respectively. Hence, a receiver operating characteristic analysis was performed to determine thresholds for the PX to detect hyperketonemia in ewes. This resulted in thresholds for moderate ketosis of BHBA concentrations of 0.7 mmol/L in blood

  12. Rural medicine via mobile network

    International Nuclear Information System (INIS)

    Srivastava, Shikha; Bharade, Sandeep; Sinha, Vineet; Ananthakrishnan, T.S.; Jindal, G.D.; Prakash, C.

    2009-01-01

    Bhabha Atomic Research Centre (BARC) has developed a handheld Tele-ECG system for providing optimum cardiac care and a Mobile Network Based Telemedicine (MNBT) utility for providing telemedicine services to isolated rural population. The handheld Tele-ECG acquires, saves and transfers the electrocardiographic signal to the expert's mobile for his advice in dealing with cardiac emergencies. Similarly, MNBT utility transfers the medical images and relevant patient data from a PC based instrument to a mobile phone for further transmission to an expert for his advice. This paper summarizes these developments. (author)

  13. The Dragonian Subsurface Abyss and Submarine Force’s Ability to Counter the Rising Threat

    Science.gov (United States)

    2013-05-23

    Navy, see Gang Deng, Chinese Maritime Activities and Socioeconomic Development, C. 2100 B.C.-1900 A.D. (Westport, Conn.: Greenwood Press, 1997...incident involving a Chinese Song “ stalking ” the Kitty Hawk Strike Group as it conducted operations in international waters near Okinawa a couple of...show of force. Actual tracking and integration within the PLAN SSN community, however, requires an 76Bill Gertz, "China Sub Stalked U.S. Fleet," The

  14. Instrumental interaction

    OpenAIRE

    Luciani , Annie

    2007-01-01

    International audience; The expression instrumental interaction as been introduced by Claude Cadoz to identify a human-object interaction during which a human manipulates a physical object - an instrument - in order to perform a manual task. Classical examples of instrumental interaction are all the professional manual tasks: playing violin, cutting fabrics by hand, moulding a paste, etc.... Instrumental interaction differs from other types of interaction (called symbolic or iconic interactio...

  15. Instrumentation development

    International Nuclear Information System (INIS)

    Ubbes, W.F.; Yow, J.L. Jr.

    1988-01-01

    Instrumentation is developed for the Civilian Radioactive Waste Management Program to meet several different (and sometimes conflicting) objectives. This paper addresses instrumentation development for data needs that are related either directly or indirectly to a repository site, but does not touch on instrumentation for work with waste forms or other materials. Consequently, this implies a relatively large scale for the measurements, and an in situ setting for instrument performance. In this context, instruments are needed for site characterization to define phenomena, develop models, and obtain parameter values, and for later design and performance confirmation testing in the constructed repository. The former set of applications is more immediate, and is driven by the needs of program design and performance assessment activities. A host of general technical and nontechnical issues have arisen to challenge instrumentation development. Instruments can be classed into geomechanical, geohydrologic, or other specialty categories, but these issues cut across artificial classifications. These issues are outlined. Despite this imposing list of issues, several case histories are cited to evaluate progress in the area

  16. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  17. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  18. SU-F-J-140: Using Handheld Stereo Depth Cameras to Extend Medical Imaging for Radiation Therapy Planning

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, C; Xing, L; Yu, S [Stanford University, Stanford, CA (United States)

    2016-06-15

    Purpose: A correct body contour is essential for the accuracy of dose calculation in radiation therapy. While modern medical imaging technologies provide highly accurate representations of body contours, there are times when a patient’s anatomy cannot be fully captured or there is a lack of easy access to CT/MRI scanning. Recently, handheld cameras have emerged that are capable of performing three dimensional (3D) scans of patient surface anatomy. By combining 3D camera and medical imaging data, the patient’s surface contour can be fully captured. Methods: A proof-of-concept system matches a patient surface model, created using a handheld stereo depth camera (DC), to the available areas of a body contour segmented from a CT scan. The matched surface contour is then converted to a DICOM structure and added to the CT dataset to provide additional contour information. In order to evaluate the system, a 3D model of a patient was created by segmenting the body contour with a treatment planning system (TPS) and fabricated with a 3D printer. A DC and associated software were used to create a 3D scan of the printed phantom. The surface created by the camera was then registered to a CT model that had been cropped to simulate missing scan data. The aligned surface was then imported into the TPS and compared with the originally segmented contour. Results: The RMS error for the alignment between the camera and cropped CT models was 2.26 mm. Mean distance between the aligned camera surface and ground truth model was −1.23 +/−2.47 mm. Maximum deviations were < 1 cm and occurred in areas of high concavity or where anatomy was close to the couch. Conclusion: The proof-of-concept study shows an accurate, easy and affordable method to extend medical imaging for radiation therapy planning using 3D cameras without additional radiation. Intel provided the camera hardware used in this study.

  19. Geocam Space: Enhancing Handheld Digital Camera Imagery from the International Space Station for Research and Applications

    Science.gov (United States)

    Stefanov, William L.; Lee, Yeon Jin; Dille, Michael

    2016-01-01

    Handheld astronaut photography of the Earth has been collected from the International Space Station (ISS) since 2000, making it the most temporally extensive remotely sensed dataset from this unique Low Earth orbital platform. Exclusive use of digital handheld cameras to perform Earth observations from the ISS began in 2004. Nadir viewing imagery is constrained by the inclined equatorial orbit of the ISS to between 51.6 degrees North and South latitude, however numerous oblique images of land surfaces above these latitudes are included in the dataset. While unmodified commercial off-the-shelf digital cameras provide only visible wavelength, three-band spectral information of limited quality current cameras used with long (400+ mm) lenses can obtain high quality spatial information approaching 2 meters/ground pixel resolution. The dataset is freely available online at the Gateway to Astronaut Photography of Earth site (http://eol.jsc.nasa.gov), and now comprises over 2 million images. Despite this extensive image catalog, use of the data for scientific research, disaster response, commercial applications and visualizations is minimal in comparison to other data collected from free-flying satellite platforms such as Landsat, Worldview, etc. This is due primarily to the lack of fully-georeferenced data products - while current digital cameras typically have integrated GPS, this does not function in the Low Earth Orbit environment. The Earth Science and Remote Sensing (ESRS) Unit at NASA Johnson Space Center provides training in Earth Science topics to ISS crews, performs daily operations and Earth observation target delivery to crews through the Crew Earth Observations (CEO) Facility on board ISS, and also catalogs digital handheld imagery acquired from orbit by manually adding descriptive metadata and determining an image geographic centerpoint using visual feature matching with other georeferenced data, e.g. Landsat, Google Earth, etc. The lack of full geolocation

  20. Vision though afocal instruments: generalized magnification and eye-instrument interaction

    Science.gov (United States)

    Harris, William F.; Evans, Tanya

    2018-04-01

    In Gaussian optics all observers experience the same magnification, the instrument's angular magnification, when viewing distant objects though a telescope or other afocal instruments. However, analysis in linear optics shows that this is not necessarily so in the presence of astigmatism. Because astigmatism may distort and rotate images it is appropriate to work with generalized angular magnification represented by a 2 × 2 matrix. An expression is derived for the generalized magnification for an arbitrary eye looking through an arbitrary afocal instrument. With afocal instruments containing astigmatic refracting elements not all eyes experience the same generalized magnification; there is interaction between eye and instrument. Eye-instrument interaction may change as the instrument is rotated about its longitudinal axis, there being no interaction in particular orientations. A simple numerical example is given. For sake of completeness, expressions for generalized magnification are also presented in the case of instruments that are not afocal and objects that are not distant.

  1. Suitability of capillary blood obtained by a minimally invasive lancet technique to detect subclinical ketosis in dairy cows by using 3 different electronic hand-held devices.

    Science.gov (United States)

    Kanz, P; Drillich, M; Klein-Jöbstl, D; Mair, B; Borchardt, S; Meyer, L; Schwendenwein, I; Iwersen, M

    2015-09-01

    The objective of this study was to evaluate the suitability of capillary blood obtained by a minimally invasive lancet technique to detect subclinical ketosis in 49 prepartum and 191 postpartum Holstein-Friesian cows using 3 different electronic hand-held devices [FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini), NovaVet (NOV, Nova Biomedical)]. The β-hydroxybutyrate (BHBA) concentration in serum harvested from coccygeal blood samples was analyzed in a laboratory and used as a reference value. Capillary samples were obtained from the skin of the exterior vulva by using 1 of 3 different lancets. In all samples, the concentration of BHBA was immediately analyzed with all 3 hand-held devices used in random order. All lancets used in the study were eligible for capillary blood collection but differed in the total number of incisions needed. Spearman correlation coefficients between the BHBA concentrations in capillary blood and the reference test were highly significant with 83% for the FSP, 73% for the NOV, and 63% for the GLX. Using capillary blood, the FSP overestimated the mean BHBA concentration compared with the reference test (+0.08 mmol/L), whereas the GLX and NOV underestimated the mean concentration (-0.07 and -0.01 mmol/L). When a BHBA concentration of 1.2 mmol/L in serum was used to define subclinical ketosis, the corresponding analyses of receiver operating characteristics resulted in optimized thresholds for capillary blood of 1.1 mmol/L for the NOV and GLX devices, and of 1.0 mmol/L for the FSP. Based on these thresholds, sensitivities (Se) and specificities (Sp) were 89 and 84% for the NOV, 80 and 89% for the GLX, and 100 and 76% for the FSP. Based on a serum BHBA concentration of 1.4 mmol/L, analyses of receiver operating characteristics resulted in optimized cut-offs of 1.4 mmol/L for the FSP (Se 100%, Sp 92%), 1.3 mmol/L for the NOV (Se 80%, Sp 95%), and 1.1 mmol/L (Se 90%, Sp 85%) for the GLX. Using these optimized thresholds

  2. Drift from the Use of Hand-Held Knapsack Pesticide Sprayers in Boyacá (Colombian Andes).

    Science.gov (United States)

    García-Santos, Glenda; Feola, Giuseppe; Nuyttens, David; Diaz, Jaime

    2016-05-25

    Offsite pesticide losses in tropical mountainous regions have been little studied. One example is measuring pesticide drift soil deposition, which can support pesticide risk assessment for surface water, soil, bystanders, and off-target plants and fauna. This is considered a serious gap, given the evidence of pesticide-related poisoning in those regions. Empirical data of drift deposition of a pesticide surrogate, Uranine tracer, within one of the highest potato-producing regions in Colombia, characterized by small plots and mountain orography, is presented. High drift values encountered in this study reflect the actual spray conditions using hand-held knapsack sprayers. Comparison between measured and predicted drift values using three existing empirical equations showed important underestimation. However, after their optimization based on measured drift information, the equations showed a strong predictive power for this study area and the study conditions. The most suitable curve to assess mean relative drift was the IMAG calculator after optimization.

  3. Electrotactile Feedback for Handheld Devices with Touch Screen and Simulation of Roughness.

    Science.gov (United States)

    Altinsoy, M E; Merchel, S

    2012-01-01

    We present a novel electrotactile display that can be integrated into current handheld devices with touch screens. In this display, tactile information is presented to the fingertip of the user by transmitting small currents through electrodes. Experiments were conducted to investigate the perception of simulated textures using this electrotactile display technique. One fundamental feature of texture, which is the focus of this study, is roughness. The aim of the first experiment was to investigate the relationship between electrotactile stimulation parameters such as current and pulse frequency and the perception of roughness. An increase in the current magnitude resulted in an increase in perceived roughness. The aim of the second experiment was to investigate parameter combinations of electrotactile stimuli can be used to simulate textures. Subjects adjusted the intensity and frequency of the current stimuli until the simulated textures were perceived as being equal to reference textures such as sandpapers of varying grit numbers and grooved woods with varying groove widths. Subjects tended to find an electrotactile stimulus with a high current magnitude and a low pulse frequency more suitable to represent rough surfaces. They tended to find just-perceptible current magnitudes suitable for very smooth surfaces and did not show a preference for any frequency.

  4. Pancreatitis Quality of Life Instrument: Development of a new instrument

    Directory of Open Access Journals (Sweden)

    Wahid Wassef

    2014-02-01

    Full Text Available Objectives: The goal of this project was to develop the first disease-specific instrument for the evaluation of quality of life in chronic pancreatitis. Methods: Focus groups and interview sessions were conducted, with chronic pancreatitis patients, to identify items felt to impact quality of life which were subsequently formatted into a paper-and-pencil instrument. This instrument was used to conduct an online survey by an expert panel of pancreatologists to evaluate its content validity. Finally, the modified instrument was presented to patients during precognitive testing interviews to evaluate its clarity and appropriateness. Results: In total, 10 patients were enrolled in the focus groups and interview sessions where they identified 50 items. Once redundant items were removed, the 40 remaining items were made into a paper-and-pencil instrument referred to as the Pancreatitis Quality of Life Instrument. Through the processes of content validation and precognitive testing, the number of items in the instrument was reduced to 24. Conclusions: This marks the development of the first disease-specific instrument to evaluate quality of life in chronic pancreatitis. It includes unique features not found in generic instruments (economic factors, stigma, and spiritual factors. Although this marks a giant step forward, psychometric evaluation is still needed prior to its clinical use.

  5. Handheld Navigation Device and Patient-Specific Cutting Guides Result in Similar Coronal Alignment for Primary Total Knee Arthroplasty: a Retrospective Matched Cohort Study.

    Science.gov (United States)

    Steinhaus, Michael E; McLawhorn, Alexander S; Richardson, Shawn S; Maher, Patrick; Mayman, David J

    2016-10-01

    Proper alignment of total knee arthroplasty (TKA) is essential for TKA function and may reduce the risk of aseptic failure. Technologies that prevent malalignment may reduce the risk of revision surgery. The purpose of this study was to compare two competing TKA systems that purport improved alignment: patient-specific instrumentation (PSI), and a handheld portable navigation device (NAV). After IRB approval, 49 consecutive PSI TKAs (40 patients) were matched based on preoperative characteristics to 49 NAV TKAs (40 patients) performed by a single surgeon. A blinded observer measured alignment on digital radiographs. Operating room records were reviewed for procedure times. Two-tailed paired sample t tests and McNemar's test were used as appropriate. Alpha level was 0.05 for all tests. Preoperative cohort characteristics were not different. Mean postoperative long-leg mechanical alignment was within ±1° of neutral for both groups, although statistically different ( p  = 0.026). There were no other significant differences in coronal alignment. PSI exhibited significantly greater posterior tibial slope (4.4°) compared to NAV (2.7°) ( p  = 0.004); PSI resulted in significantly more outliers (>6°; p  = 0.004). Procedure time for unilateral TKAs was lower for PSI (74.4 min) compared to that for NAV (80.6 min; p  = 0.023). NAV and PSI technologies provided excellent coronal plane alignment. NAV was better for sagittal tibial slope, while PSI procedure times were shorter for unilateral TKA. The impact of these technologies on patient-reported outcomes and TKA survivorship is controversial and should be the focus of future research.

  6. Handheld echocardiography versus auscultation for detection of rheumatic heart disease.

    Science.gov (United States)

    Godown, Justin; Lu, Jimmy C; Beaton, Andrea; Sable, Craig; Mirembe, Grace; Sanya, Richard; Aliku, Twalib; Yu, Sunkyung; Lwabi, Peter; Webb, Catherine L; Ensing, Gregory J

    2015-04-01

    Rheumatic heart disease (RHD) remains a major public health concern in developing countries, and routine screening has the potential to improve outcomes. Standard portable echocardiography (STAND) is far more sensitive than auscultation for the detection of RHD but remains cost-prohibitive in resource-limited settings. Handheld echocardiography (HAND) is a lower-cost alternative. The purpose of this study was to assess the incremental value of HAND over auscultation to identify RHD. RHD screening was completed for schoolchildren in Gulu, Uganda, by using STAND performed by experienced echocardiographers. Any child with mitral or aortic regurgitation or stenosis plus a randomly selected group of children with normal STAND findings underwent HAND and auscultation. STAND and HAND studies were interpreted by 6 experienced cardiologists using the 2012 World Heart Federation criteria. Sensitivity and specificity of HAND and auscultation for the detection of RHD and pathologic mitral or aortic regurgitation were calculated by using STAND as the gold standard. Of 4773 children who underwent screening with STAND, a subgroup of 1317 children underwent HAND and auscultation. Auscultation had uniformly poor sensitivity for the detection of RHD or valve disease. Sensitivity was significantly improved by using HAND compared with auscultation for the detection of definite RHD (97.8% vs 22.2%), borderline or definite RHD (78.4% vs 16.4%), and pathologic aortic insufficiency (81.8% vs 13.6%). Auscultation alone is a poor screening test for RHD. HAND significantly improves detection of RHD and may be a cost-effective screening strategy for RHD in resource-limited settings. Copyright © 2015 by the American Academy of Pediatrics.

  7. Design, construction and performance of a portable handheld electrohydrodynamic multi-needle spray gun for biomedical applications.

    Science.gov (United States)

    Sofokleous, Panagiotis; Stride, Eleanor; Bonfield, William; Edirisinghe, Mohan

    2013-01-01

    Electrohydrodynamic (EHD) processing has attracted substantial interest in the technological and pharmaceutical sectors in recent years. Given the complexity of the process, exploring new ideas for EHD electrospraying and electrospinning delivery is a challenge. In this article, the design, construction and testing of a portable handheld EHD multi-needle device are described to produce multifunctional particles and fibers. Solid and encapsulated polymer particles and fibers were generated in order to study the performance of the device. The intrinsic properties of the feed solution/suspension and the processing conditions were adjusted to ensure robustness of the process and give uniform and reproducible products, with diameters ranging from the sub-micrometer scale to a few micrometers. These products have a broad range of applications in many advanced industrial sectors e.g. drug delivery systems, wound dressing patches, low calorie food products and cosmetics. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Non-conventional applications of a noninvasive portable X-ray diffraction/fluorescence instrument

    International Nuclear Information System (INIS)

    Chiari, Giacomo; Sarrazin, Philippe; Heginbotham, Arlen

    2016-01-01

    Noninvasive techniques have become widespread in the cultural heritage analytical domain. The popular handheld X-ray fluorescence (XRF) devices give the elemental composition of all the layers that X-rays can penetrate, but no information on how atoms are bound together or at which depth they are located. A noninvasive portable X-ray powder diffraction/X-ray fluorescence (XRD/XRF) device may offer a solution to these limitations, since it can provide information on the composition of crystalline materials. This paper introduces applications of XRD beyond simple phase recognition. The two fundamental principles for XRD are: (1) the crystallites should be randomly oriented, to ensure proper intensity to all the diffraction peaks, and (2) the material should be positioned exactly in the focal plane of the instrument, respecting its geometry, as any displacement of the sample would results in 2θ shifts of the diffraction peaks. In conventional XRD, the sample is ground and set on the properly positioned sample holder. Using a noninvasive portable instrument, these two requirements are seldom fulfilled. The position, size and orientation of a given crystallite within a layered structure depend on the object itself. Equation correlating the displacement (distance from the focal plane) versus peak shift (angular difference in 2θ from the standard value) is derived and used to determine the depth at which a given substance is located. The quantitative composition of two binary Cu/Zn alloys, simultaneously present, was determined measuring the cell volume and using Vegard's law. The analysis of the whole object gives information on the texture and possible preferred orientations of the crystallites, which influences the peak intensity. This allows for the distinction between clad and electroplated daguerreotypes in the case of silver and between ancient and modern gilding for gold. Analyses of cross sections can be carried out successfully. Finally, beeswax, used in Roman

  9. Research on atmospheric CO2 remote sensing with open-path tunable diode laser absorption spectroscopy and comparison methods

    Science.gov (United States)

    Xin, Fengxin; Guo, Jinjia; Sun, Jiayun; Li, Jie; Zhao, Chaofang; Liu, Zhishen

    2017-06-01

    An open-path atmospheric CO2 measurement system was built based on tunable diode laser absorption spectroscopy (TDLAS). The CO2 absorption line near 2 μm was selected, measuring the atmospheric CO2 with direct absorption spectroscopy and carrying on the comparative experiment with multipoint measuring instruments of the open-path. The detection limit of the TDLAS system is 1.94×10-6. The calibration experiment of three AZ-7752 handheld CO2 measuring instruments was carried out with the Los Gatos Research gas analyzer. The consistency of the results was good, and the handheld instrument could be used in the TDLAS system after numerical calibration. With the contrast of three AZ-7752 and their averages, the correlation coefficients are 0.8828, 0.9004, 0.9079, and 0.9393 respectively, which shows that the open-path TDLAS has the best correlation with the average of three AZ-7752 and measures the concentration of atmospheric CO2 accurately. Multipoint measurement provides a convenient comparative method for open-path TDLAS.

  10. New instruments for soil physics class: Improving the laboratory and field seminars

    Science.gov (United States)

    Klipa, Vladimir; Jankovec, Jakub; Snehota, Michal

    2014-05-01

    Teaching soil science and soil physics is an important part of the curriculum of many programs with focus on technical and natural sciences. Courses of soil science and namely soil physics have a long tradition at the faculty of Civil Engineering of the Czech Technical University in Prague. Students receive the theoretical foundations about soil classification, soil physics, soil chemistry and soil hydraulic characteristics in the course. In practical seminars students perform measurements of physical, hydraulic and chemical characteristics of soils, thus a comprehensive survey of soil is done in the given site. So far, students had the opportunity to use old, manually operated instrumentation. The project aims to improve the attractiveness of soil physics course and to extend the practical skills of students by introducing new tasks and by involving modern automated equipment. New instruments were purchased with the support of the Ministry of Education, Youth and Sports of the Czech Republic under the project FRVS No. 1162/2013 G1. Specifically, two tensiometers T8 with multi-functional handheld read-out unit (UMS, GmbH) and manual Mini Disk Infiltrometer (Decagon Devices, Inc.) were purchased and incorporated into the course. In addition, newly designed MultiDisk the automated mini disk Infiltrometer (CTU in Prague) and combined temperature and soil moisture TDT sensor TMS 2 (TOMST®, s.r.o.), were made freely available for soil physics classes and included into the courses. Online tutorials and instructional videos were developed. Detailed multimedia teaching materials were introduced so that students are able to work more independently. Students will practice operating the digital tensiometer T8 with integrated temperature sensor and manual Mini Disk Infiltrometer (diameter disk: 4.4 cm, suction range: 0.5 to 7.0 cm of suction) and MultiDisk the automated mini disk Infiltrometer (see Klipa et al., EGU2014-7230) and combined temperature and soil moisture TDT

  11. Handheld mechanical nociceptive threshold testing in dairy cows - intra-individual variation, inter-observer agreement and variation over time.

    Science.gov (United States)

    Raundal, Peter M; Andersen, Pia H; Toft, Nils; Forkman, Björn; Munksgaard, Lene; Herskin, Mette S

    2014-11-01

    To examine the use of handheld methodology to assess mechanical nociceptive threshold (MNT) on cows kept loose-housed. Prospective randomized partial cross-over experimental study. A one-factor (test day) design was used to evaluate MNT over time. One hundred and fifteen healthy, loose-housed Danish Holstein cattle. We evaluated intra-individual variation, inter-observer agreement and variation over time of MNT using two handheld devices and two stimulation sites. Mechanical, ramped stimulations were performed with an algometer (6.5 mm diameter steel probe, 0-10.0 kgf) or an electronic von Frey device (plastic tip with diameter 0.8 mm, 0-1000 gf). Each cow received 5-6 consecutive stimulations within a 2 × 5 cm skin area on the dorsal or lateral aspect of the left third metatarsus until an avoidance reaction occurred. We investigated the difference in precision [expressed as coefficient of variation (CV)] between the combinations of devices and stimulation sites. The inter-observer agreement and the difference in MNT between test day 1, 3, 7, 10 and 24 were investigated for selected combinations. Data were analysed in mixed models and Bland-Altman as relevant. The CVs did not differ [range 0.34-0.52 (p = 0.1)]. Difference between observers (95% limits) was 0.2 kgf (2.8) and 4 gf (369) for the algometer and von Frey device, respectively. Mechanical nociceptive threshold increased from 361 on test day one to 495 gf on test day 24 (p < 0.01). All methods showed a high degree of intra-individual variation, and no combination of device and stimulation site showed superior precision. Mean difference between observers was low, and MNT was not consistent over time. Further development of the methods is required before they can be used in research to investigate possible relations between claw lesions and hyperalgesia. © 2014 The Authors Veterinary Anaesthesia and Analgesia published by John Wiley & Sons Ltd on behalf of Association of Veterinary Anaesthetists and the

  12. Novel instrumentation of multispectral imaging technology for detecting tissue abnormity

    Science.gov (United States)

    Yi, Dingrong; Kong, Linghua

    2012-10-01

    Multispectral imaging is becoming a powerful tool in a wide range of biological and clinical studies by adding spectral, spatial and temporal dimensions to visualize tissue abnormity and the underlying biological processes. A conventional spectral imaging system includes two physically separated major components: a band-passing selection device (such as liquid crystal tunable filter and diffraction grating) and a scientific-grade monochromatic camera, and is expensive and bulky. Recently micro-arrayed narrow-band optical mosaic filter was invented and successfully fabricated to reduce the size and cost of multispectral imaging devices in order to meet the clinical requirement for medical diagnostic imaging applications. However the challenging issue of how to integrate and place the micro filter mosaic chip to the targeting focal plane, i.e., the imaging sensor, of an off-shelf CMOS/CCD camera is not reported anywhere. This paper presents the methods and results of integrating such a miniaturized filter with off-shelf CMOS imaging sensors to produce handheld real-time multispectral imaging devices for the application of early stage pressure ulcer (ESPU) detection. Unlike conventional multispectral imaging devices which are bulky and expensive, the resulting handheld real-time multispectral ESPU detector can produce multiple images at different center wavelengths with a single shot, therefore eliminates the image registration procedure required by traditional multispectral imaging technologies.

  13. Instrument performance evaluation

    International Nuclear Information System (INIS)

    Swinth, K.L.

    1993-03-01

    Deficiencies exist in both the performance and the quality of health physics instruments. Recognizing the implications of such deficiencies for the protection of workers and the public, in the early 1980s the DOE and the NRC encouraged the development of a performance standard and established a program to test a series of instruments against criteria in the standard. The purpose of the testing was to establish the practicality of the criteria in the standard, to determine the performance of a cross section of available instruments, and to establish a testing capability. Over 100 instruments were tested, resulting in a practical standard and an understanding of the deficiencies in available instruments. In parallel with the instrument testing, a value-impact study clearly established the benefits of implementing a formal testing program. An ad hoc committee also met several times to establish recommendations for the voluntary implementation of a testing program based on the studies and the performance standard. For several reasons, a formal program did not materialize. Ongoing tests and studies have supported the development of specific instruments and have helped specific clients understand the performance of their instruments. The purpose of this presentation is to trace the history of instrument testing to date and suggest the benefits of a centralized formal program

  14. Extra-oral dental radiography for disaster victims using a flat panel X-ray detector and a hand-held X-ray generator.

    Science.gov (United States)

    Ohtani, M; Oshima, T; Mimasaka, S

    2017-12-01

    Forensic odontologists commonly incise the skin for post-mortem dental examinations when it is difficult to open the victim's mouth. However, it is prohibited by law to incise dead bodies without permission in Japan. Therefore, we attempted using extra-oral dental radiography, using a digital X-ray equipment with rechargeable batteries, to overcome this restriction. A phantom was placed in the prone position on a table, and three plain dental radiographs were used per case: "lateral oblique radiographs" for left and right posterior teeth and a "contact radiograph" for anterior teeth were taken using a flat panel X-ray detector and a hand-held X-ray generator. The resolving power of the images was measured by a resolution test chart, and the scattered X-ray dose was measured using an ionization chamber-type survey meter. The resolving power of the flat panel X-ray detector was 3.0 lp/mm, which was less than that of intra-oral dental methods, but the three extra-oral plain dental radiographs provided the overall dental information from outside of the mouth, and this approach was less time-consuming. In addition, the higher dose of scattered X-rays was laterally distributed, but the dose per case was much less than that of intra-oral dental radiographs. Extra-oral plain dental radiography can be used for disaster victim identification by dental methods even when it is difficult to open the mouth. Portable and rechargeable devices, such as a flat panel X-ray detector and a hand-held X-ray generator, are convenient to bring and use anywhere, even at a disaster scene lacking electricity and water.

  15. Hip strength assessment using handheld dynamometry is subject to intertester bias when testers are of different sex and strength

    DEFF Research Database (Denmark)

    Thorborg, K; Bandholm, T; Schick, M

    2013-01-01

    Handheld dynamometry (HHD) is a promising tool for obtaining reliable hip strength measurements in the clinical setting, but intertester reliability has been questioned, especially in situations where testers exhibit differences in upper-extremity muscle strength (male vs female). The purpose...... of this study was to examine the intertester reliability concerning strength assessments of hip abduction, adduction, external and internal rotation, flexion and extension using HHD, and to test whether systematic differences in test values exist between testers of different upper-extremity strength. Fifty...... healthy individuals (29 women), aged 25 ± 5 years were included. Two physiotherapist students (one female, one male) of different upper-extremity strength performed the measurements. The tester order and strength test order were randomized. Intraclass correlation coefficients were used to quantify...

  16. Development of a Handheld Line Information Reader and Generator for Efficient Management of Optical Communication Lines.

    Science.gov (United States)

    Lee, Jaeyul; Kwon, Hyungwoo; Song, Jaewon; Jeon, Mansik; Kim, Jeehyun

    2017-08-24

    A handheld line information reader and a line information generator were developed for the efficient management of optical communication lines. The line information reader consists of a photo diode, trans-impedance amplifier, voltage amplifier, microcontroller unit, display panel, and communication modules. The line information generator consists of a laser diode, laser driving circuits, microcontroller unit, and communication modules. The line information reader can detect the optical radiation field of the test line by bending the optical fiber. To enhance the sensitivity of the line information reader, an additional lens was used with a focal length of 4.51 mm. Moreover, the simulation results obtained through BeamPROP ® software from Synopsys, Inc. demonstrated a stronger optical radiation field of the fiber due to a longer transmission wavelength and larger bending angle of the fiber. Therefore, the developed devices can be considered as useful tools for the efficient management of optical communication lines.

  17. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2000-01-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised

  18. Utility of hand-held echocardiography in outpatient pediatric cardiology management.

    Science.gov (United States)

    Riley, Alan; Sable, Craig; Prasad, Aparna; Spurney, Christopher; Harahsheh, Ashraf; Clauss, Sarah; Colyer, Jessica; Gierdalski, Marcin; Johnson, Ashley; Pearson, Gail D; Rosenthal, Joanna

    2014-12-01

    Adult patient series have shown hand-held echocardiography (echo) units (HHE) to be accurate for rapid diagnosis and triage. This is the first study to evaluate the ability of HHE to inform decision making in outpatient pediatric cardiology. New pediatric cardiology patients in outpatient clinics staffed by six pediatric cardiologists (experience 1-17 years) were prospectively enrolled if an echocardiogram (echo) was ordered during their initial visit. After history and physical examination and before a standard echo, the cardiologists performed a bedside HHE examination (GE Vscan 1.7-3.8 MHz), documented findings, and made a clinical decision. Diagnoses and decisions based on HHE were compared with final management after the standard echo. The study enrolled 101 subjects (ages 9 days to 19 years). The cardiologists considered HHE imaging adequate for decision making for 80 of the 101 subjects. For 77 of the 80 subjects with acceptable HHE imaging (68/68 normal and 9/12 abnormal standard echoes), the HHE-based primary diagnoses and decisions agreed with the final management. The sensitivity of HHE was 75 % (95 % confidence interval [CI] 43-94 %) and the positive predictive value 100 % (95 % CI 66-100 %) for pediatric heart disease. The agreement between standard echocardiography and HHE imaging was substantial (κ = 0.82). Excluding one of the least experienced cardiologists, HHE provided the basis for correct cardiac diagnoses and management for all the subjects with acceptable HHE imaging (58/58 normal and 9/9 abnormal echoes). In outpatient pediatric cardiology, HHE has potential as a tool to complement physical examination. Further investigation is needed to evaluate how value improves with clinical experience.

  19. Performing the Super Instrument

    DEFF Research Database (Denmark)

    Kallionpaa, Maria

    2016-01-01

    can empower performers by producing super instrument works that allow the concert instrument to become an ensemble controlled by a single player. The existing instrumental skills of the performer can be multiplied and the qualities of regular acoustic instruments extended or modified. Such a situation......The genre of contemporary classical music has seen significant innovation and research related to new super, hyper, and hybrid instruments, which opens up a vast palette of expressive potential. An increasing number of composers, performers, instrument designers, engineers, and computer programmers...... have become interested in different ways of “supersizing” acoustic instruments in order to open up previously-unheard instrumental sounds. Super instruments vary a great deal but each has a transformative effect on the identity and performance practice of the performing musician. Furthermore, composers...

  20. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2000-07-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised.

  1. VIRUS instrument enclosures

    Science.gov (United States)

    Prochaska, T.; Allen, R.; Mondrik, N.; Rheault, J. P.; Sauseda, M.; Boster, E.; James, M.; Rodriguez-Patino, M.; Torres, G.; Ham, J.; Cook, E.; Baker, D.; DePoy, Darren L.; Marshall, Jennifer L.; Hill, G. J.; Perry, D.; Savage, R. D.; Good, J. M.; Vattiat, Brian L.

    2014-08-01

    The Visible Integral-Field Replicable Unit Spectrograph (VIRUS) instrument will be installed at the Hobby-Eberly Telescope† in the near future. The instrument will be housed in two enclosures that are mounted adjacent to the telescope, via the VIRUS Support Structure (VSS). We have designed the enclosures to support and protect the instrument, to enable servicing of the instrument, and to cool the instrument appropriately while not adversely affecting the dome environment. The system uses simple HVAC air handling techniques in conjunction with thermoelectric and standard glycol heat exchangers to provide efficient heat removal. The enclosures also provide power and data transfer to and from each VIRUS unit, liquid nitrogen cooling to the detectors, and environmental monitoring of the instrument and dome environments. In this paper, we describe the design and fabrication of the VIRUS enclosures and their subsystems.

  2. Flexible CMOS low-noise amplifiers for beyond-3G wireless hand-held devices

    Science.gov (United States)

    Becerra-Alvarez, Edwin C.; Sandoval-Ibarra, Federico; de la Rosa, José M.

    2009-05-01

    This paper explores the use of reconfigurable Low-Noise Amplifiers (LNAs) for the implementation of CMOS Radio Frequency (RF) front-ends in the next generation of multi-standard wireless transceivers. Main circuit strategies reported so far for multi-standard LNAs are reviewed and a novel flexible LNA intended for Beyond-3G RF hand-held terminals is presented. The proposed LNA circuit consists of a two-stage topology that combines inductive-source degeneration with PMOS-varactor based tuning network and a programmable load to adapt its performance to different standard specifications without penalizing the circuit noise and with a reduced number of inductors as compared to previous reported reconfigurable LNAs. The circuit has been designed in a 90-nm CMOS technology to cope with the requirements of the GSM, WCDMA, Bluetooth and WLAN (IEEE 802.11b-g) standards. Simulation results, including technology and packaging parasitics, demonstrate correct operation of the circuit for all the standards under study, featuring NF13.3dB and IIP3>10.9dBm, over a 1.85GHz-2.4GHz band, with an adaptive power consumption between 17mW and 22mW from a 1-V supply voltage. Preliminary experimental measurements are included, showing a correct reconfiguration operation within the operation band.

  3. The Takei Handheld Dynamometer: An Effective Clinical Outcome Measure Tool for Hand and Wrist Function in Boxing.

    Science.gov (United States)

    Gatt, Ian; Smith-Moore, Sophie; Steggles, Charlie; Loosemore, Mike

    2018-05-01

    The aim of this article was to explore retrospectively the Takei dynamometer as a valid and reliable outcome measure tool for hand and wrist pathology in the Great Britain amateur boxing squad between 2010 and 2014. Longitudinal retrospective injury surveillance of the Great Britain boxing squad was performed from 2010 to 2014. The location, region affected, description, and duration of each injury were recorded by the team doctor and team physiotherapists. For each significant injury, we recorded hand grip scores using the Takei handheld dynamometer and compared the scores with baseline measures. At the hand, fractures and dislocations were highly detected with an average difference of 40.2% ( P 20% should be highly considered for significant pathology. The Takei dynamometer is a valid and reliable outcome measure tool for hand and wrist pathologies in boxing. Our study highlights the importance of appropriate clinical tools to guide injury management in this sport.

  4. Health physics instrument manual

    International Nuclear Information System (INIS)

    Gupton, E.D.

    1978-08-01

    The purpose of this manual is to provide apprentice health physics surveyors and other operating groups not directly concerned with radiation detection instruments a working knowledge of the radiation detection and measuring instruments in use at the Laboratory. The characteristics and applications of the instruments are given. Portable instruments, stationary instruments, personnel monitoring instruments, sample counters, and miscellaneous instruments are described. Also, information sheets on calibration sources, procedures, and devices are included. Gamma sources, beta sources, alpha sources, neutron sources, special sources, a gamma calibration device for badge dosimeters, and a calibration device for ionization chambers are described

  5. Handheld Raman Spectroscopy for the Distinction of Essential Oils Used in the Cosmetics Industry

    Directory of Open Access Journals (Sweden)

    Paul Vargas Jentzsch

    2015-05-01

    Full Text Available Essential oils are highly appreciated by the cosmetics industry because they have antimicrobial and antioxidant properties, among others. Since essential oils are natural products, their inclusion in cosmetic formulations is a common practice. Currently, low-quality and/or adulterated essential oils can be found on the market; therefore, analytical methods for control are required. Raman spectroscopy is a versatile technique that can be used for quality control tasks; the portability of modern devices expand the analytical possibilities also to in situ measurements. Fifteen essential oils of interest for the cosmetics industry were measured using a handheld Raman spectrometer, and the assignment of the main bands observed in their average spectra was proposed. In most cases, it is possible to distinguish the essential oils by a simple visual inspection of their characteristic Raman bands. However, for essential oils extracted from closely-related vegetable species and containing the same main component in a very high proportion, the visual inspection of the spectra may be not enough, and the application of chemometric methods is suggested. Characteristic Raman bands for each essential oil can be used to both identify the essential oils and detect adulterations.

  6. Detection of fecal contamination on beef meat surfaces using handheld fluorescence imaging device (HFID)

    Science.gov (United States)

    Oh, Mirae; Lee, Hoonsoo; Cho, Hyunjeong; Moon, Sang-Ho; Kim, Eun-Kyung; Kim, Moon S.

    2016-05-01

    Current meat inspection in slaughter plants, for food safety and quality attributes including potential fecal contamination, is conducted through by visual examination human inspectors. A handheld fluorescence-based imaging device (HFID) was developed to be an assistive tool for human inspectors by highlighting contaminated food and food contact surfaces on a display monitor. It can be used under ambient lighting conditions in food processing plants. Critical components of the imaging device includes four 405-nm 10-W LEDs for fluorescence excitation, a charge-coupled device (CCD) camera, optical filter (670 nm used for this study), and Wi-Fi transmitter for broadcasting real-time video/images to monitoring devices such as smartphone and tablet. This study aimed to investigate the effectiveness of HFID in enhancing visual detection of fecal contamination on red meat, fat, and bone surfaces of beef under varying ambient luminous intensities (0, 10, 30, 50 and 70 foot-candles). Overall, diluted feces on fat, red meat and bone areas of beef surfaces were detectable in the 670-nm single-band fluorescence images when using the HFID under 0 to 50 foot-candle ambient lighting.

  7. Nuclear reactor instrumentation

    International Nuclear Information System (INIS)

    Duncombe, E.; McGonigal, G.

    1975-01-01

    A liquid metal cooled nuclear reactor is described which has an equal number of fuel sub-assemblies and sensing instruments. Each instrument senses temperature and rate of coolant flow of a coolant derived from a group of three sub-assemblies so that an abnormal value for one sub-assembly will be indicated on three instruments thereby providing for redundancy of up to two of the three instruments. The abnormal value may be a precurser to unstable boiling of coolant

  8. Instrument validation project

    International Nuclear Information System (INIS)

    Reynolds, B.A.; Daymo, E.A.; Geeting, J.G.H.; Zhang, J.

    1996-06-01

    Westinghouse Hanford Company Project W-211 is responsible for providing the system capabilities to remove radioactive waste from ten double-shell tanks used to store radioactive wastes on the Hanford Site in Richland, Washington. The project is also responsible for measuring tank waste slurry properties prior to injection into pipeline systems, including the Replacement of Cross-Site Transfer System. This report summarizes studies of the appropriateness of the instrumentation specified for use in Project W-211. The instruments were evaluated in a test loop with simulated slurries that covered the range of properties specified in the functional design criteria. The results of the study indicate that the compact nature of the baseline Project W-211 loop does not result in reduced instrumental accuracy resulting from poor flow profile development. Of the baseline instrumentation, the Micromotion densimeter, the Moore Industries thermocouple, the Fischer and Porter magnetic flow meter, and the Red Valve Pressure transducer meet the desired instrumental accuracy. An alternate magnetic flow meter (Yokagawa) gave nearly identical results as the baseline fischer and Porter. The Micromotion flow meter did not meet the desired instrument accuracy but could potentially be calibrated so that it would meet the criteria. The Nametre on-line viscometer did not meet the desired instrumental accuracy and is not recommended as a quantitative instrument although it does provide qualitative information. The recommended minimum set of instrumentation necessary to ensure the slurry meets the Project W-058 acceptance criteria is the Micromotion mass flow meter and delta pressure cells

  9. Astronomical Instruments in India

    Science.gov (United States)

    Sarma, Sreeramula Rajeswara

    The earliest astronomical instruments used in India were the gnomon and the water clock. In the early seventh century, Brahmagupta described ten types of instruments, which were adopted by all subsequent writers with minor modifications. Contact with Islamic astronomy in the second millennium AD led to a radical change. Sanskrit texts began to lay emphasis on the importance of observational instruments. Exclusive texts on instruments were composed. Islamic instruments like the astrolabe were adopted and some new types of instruments were developed. Production and use of these traditional instruments continued, along with the cultivation of traditional astronomy, up to the end of the nineteenth century.

  10. Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study

    Science.gov (United States)

    Perraton, Luke G.; Bower, Kelly J.; Adair, Brooke; Pua, Yong-Hao; Williams, Gavin P.; McGaw, Rebekah

    2015-01-01

    Introduction Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to examine the reliability of different algorithms for RFD calculation and to examine the intra-rater, inter-rater, and inter-device reliability of HHD as well as the concurrent validity of HHD for the assessment of isometric lower limb muscle strength and power. Methods 30 healthy young adults (age: 23±5yrs, male: 15) were assessed on two sessions. Isometric muscle strength and power were measured using peak force and RFD respectively using two HHDs (Lafayette Model-01165 and Hoggan microFET2) and a criterion-reference KinCom dynamometer. Statistical analysis of reliability and validity comprised intraclass correlation coefficients (ICC), Pearson correlations, concordance correlations, standard error of measurement, and minimal detectable change. Results Comparison of RFD methods revealed that a peak 200ms moving window algorithm provided optimal reliability results. Intra-rater, inter-rater, and inter-device reliability analysis of peak force and RFD revealed mostly good to excellent reliability (coefficients ≥ 0.70) for all muscle groups. Concurrent validity analysis showed moderate to excellent relationships between HHD and fixed dynamometry for the hip and knee (ICCs ≥ 0.70) for both peak force and RFD, with mostly poor to good results shown for the ankle muscles (ICCs = 0.31–0.79). Conclusions Hand-held dynamometry has good to excellent reliability and validity for most measures of isometric lower limb strength and power in a healthy population, particularly for proximal muscle groups. To aid implementation we have created freely available software to extract these variables from data stored on the Lafayette device. Future research should examine the reliability

  11. Handheld mechanical nociceptive threshold testing in dairy cows – intra-individual variation, inter-observer agreement and variation over time

    Science.gov (United States)

    Raundal, Peter M; Andersen, Pia H; Toft, Nils; Forkman, Björn; Munksgaard, Lene; Herskin, Mette S

    2014-01-01

    Objective To examine the use of handheld methodology to assess mechanical nociceptive threshold (MNT) on cows kept loose-housed. Study design Prospective randomized partial cross-over experimental study. A one-factor (test day) design was used to evaluate MNT over time. Animals One hundred and fifteen healthy, loose-housed Danish Holstein cattle. Methods We evaluated intra-individual variation, inter-observer agreement and variation over time of MNT using two handheld devices and two stimulation sites. Mechanical, ramped stimulations were performed with an algometer (6.5 mm diameter steel probe, 0–10.0 kgf) or an electronic von Frey device (plastic tip with diameter 0.8 mm, 0–1000 gf). Each cow received 5–6 consecutive stimulations within a 2 × 5 cm skin area on the dorsal or lateral aspect of the left third metatarsus until an avoidance reaction occurred. We investigated the difference in precision [expressed as coefficient of variation (CV)] between the combinations of devices and stimulation sites. The inter-observer agreement and the difference in MNT between test day 1, 3, 7, 10 and 24 were investigated for selected combinations. Data were analysed in mixed models and Bland-Altman as relevant. Results The CVs did not differ [range 0.34–0.52 (p = 0.1)]. Difference between observers (95% limits) was 0.2 kgf (2.8) and 4 gf (369) for the algometer and von Frey device, respectively. Mechanical nociceptive threshold increased from 361 on test day one to 495 gf on test day 24 (p < 0.01). Conclusion and clinical relevance All methods showed a high degree of intra-individual variation, and no combination of device and stimulation site showed superior precision. Mean difference between observers was low, and MNT was not consistent over time. Further development of the methods is required before they can be used in research to investigate possible relations between claw lesions and hyperalgesia. PMID:24734991

  12. Instrumentation a reader

    CERN Document Server

    Pope, P

    1990-01-01

    This book contains a selection of papers and articles in instrumentation previously pub­ lished in technical periodicals and journals of learned societies. Our selection has been made to illustrate aspects of current practice and applications of instrumentation. The book does not attempt to be encyclopaedic in its coverage of the subject, but to provide some examples of general transduction techniques, of the sensing of particular measurands, of components of instrumentation systems and of instrumentation practice in two very different environments, the food industry and the nuclear power industry. We have made the selection particularly to provide papers appropriate to the study of the Open University course T292 Instrumentation. The papers have been chosen so that the book covers a wide spectrum of instrumentation techniques. Because of this, the book should be of value not only to students of instrumen­ tation, but also to practising engineers and scientists wishing to glean ideas from areas of instrumen...

  13. IOT Overview: IR Instruments

    Science.gov (United States)

    Mason, E.

    In this instrument review chapter the calibration plans of ESO IR instruments are presented and briefly reviewed focusing, in particular, on the case of ISAAC, which has been the first IR instrument at VLT and whose calibration plan served as prototype for the coming instruments.

  14. Troubleshooting in nuclear instruments

    International Nuclear Information System (INIS)

    1987-06-01

    This report on troubleshooting of nuclear instruments is the product of several scientists and engineers, who are closely associated with nuclear instrumentation and with the IAEA activities in the field. The text covers the following topics: Preamplifiers, amplifiers, scalers, timers, ratemeters, multichannel analyzers, dedicated instruments, tools, instruments, accessories, components, skills, interfaces, power supplies, preventive maintenance, troubleshooting in systems, radiation detectors. The troubleshooting and repair of instruments is illustrated by some real examples

  15. DETECTION OF DRUGSTORE BEETLES IN 9975 PACKAGES USING ACOUSTIC EMISSIONS

    Energy Technology Data Exchange (ETDEWEB)

    Shull, D.

    2013-03-04

    This report documents the initial feasibility tests performed using a commercial acoustic emission instrument for the purpose of detecting beetles in Department of Energy 9975 shipping packages. The device selected for this testing was a commercial handheld instrument and probe developed for the detection of termites, weevils, beetles and other insect infestations in wooden structures, trees, plants and soil. The results of two rounds of testing are presented. The first tests were performed by the vendor using only the hand-held instrument’s indications and real-time operator analysis of the audio signal content. The second tests included hands-free positioning of the instrument probe and post-collection analysis of the recorded audio signal content including audio background comparisons. The test results indicate that the system is promising for detecting the presence of drugstore beetles, however, additional work would be needed to improve the ease of detection and to automate the signal processing to eliminate the need for human interpretation. Mechanisms for hands-free positioning of the probe and audio background discrimination are also necessary for reliable detection and to reduce potential operator dose in radiation environments.

  16. Design of a Handheld Pseudo Random Coded UWB Radar for Human Sensing

    Directory of Open Access Journals (Sweden)

    Xia Zheng-huan

    2015-10-01

    Full Text Available This paper presents the design of a handheld pseudo random coded Ultra-WideBand (UWB radar for human sensing. The main tasks of the radar are to track the moving human object and extract the human respiratory frequency. In order to achieve perfect penetrability and good range resolution, m sequence with a carrier of 800 MHz is chosen as the transmitting signal. The modulated m-sequence can be generated directly by the high-speed DAC and FPGA to reduce the size of the radar system, and the mean power of the transmitting signal is 5 dBm. The receiver has two receiving channels based on hybrid sampling, the first receiving channel is to sample the reference signal and the second receiving channel is to obtain the radar echo. The real-time pulse compression is computed in parallel with a group of on-chip DSP48E slices in FPGA to improve the scanning rate of the radar system. Additionally, the algorithms of moving target tracking and life detection are implemented using Intel’s micro-processor, and the detection results are sent to the micro displayer fixed on the helmet. The experimental results show that the moving target located at less than 16 m far away from the wall can be tracked, and the respiratory frequency of the static human at less than 14 m far away from the wall can be extracted.

  17. Can handheld micropower impulse radar technology be used to detect pneumothorax? Initial experience in a European trauma centre.

    Science.gov (United States)

    Albers, C E; Haefeli, P C; Zimmermann, H; de Moya, M; Exadaktylos, A K

    2013-05-01

    Pneumothoraces are a common injury pattern in emergency medicine. Rapid and safe identification can reduce morbidity and mortality. A new handheld, battery powered device, the Pneumoscan (CE 561036, PneumoSonics Inc., Cleveland, OH, USA), using micropower impulse radar (MIR) technology, has recently been introduced in Europe for the rapid and reliable detection of PTX. However, this technology has not yet been tested in trauma patients. This is the first quality control evaluation to report on emergency room performance of a new device used in the trauma setting. This study was performed at a Level I trauma centre in Switzerland. All patients with thoracic trauma and undergoing chest X-ray and CT-scan were eligible for the study. Readings were performed before the chest X-ray and CT scan. The patients had eight lung fields tested (four on each side). All readings with the Pneumoscan were performed by two junior residents in our department who had previously received an instructional tutorial of 15min. The qualitative MIR results were blinded, and stored on the device. We then compared the results of the MIR to those of the clinical examination, chest X-ray and CT-scan. 50 patients were included, with a mean age of 46 (SD 17) years. Seven patients presented with PTX diagnosed by CT; six of these were detected by Pneumoscan, leading to an overall sensitivity of 85.7 (95% confidence interval 42.1-99.6)%. Only two of seven PTX were found during clinical examination and on chest X-ray (sensitivity 28.6 (95% CI 3.7-71.0)%). Of the remaining 43 of 50 patients without PTX, one false-positive PTX was found by the Pneumoscan, resulting in a specificity of 97.7 (95% CI 87.7-99.9)%. The Pneumoscan is an easy to use handheld technology with reliable results. In this series, the sensitivity to detect a PTX by the Pneumoscan was higher than by clinical examination and chest X-ray. Further studies with higher case numbers and a prospective study design are needed to confirm our

  18. Instrumentation

    International Nuclear Information System (INIS)

    Muehllehner, G.; Colsher, J.G.

    1982-01-01

    This chapter reviews the parameters which are important to positron-imaging instruments. It summarizes the options which various groups have explored in designing tomographs and the methods which have been developed to overcome some of the limitations inherent in the technique as well as in present instruments. The chapter is not presented as a defense of positron imaging versus single-photon or other imaging modality, neither does it contain a description of various existing instruments, but rather stresses their common properties and problems. Design parameters which are considered are resolution, sampling requirements, sensitivity, methods of eliminating scattered radiation, random coincidences and attenuation. The implementation of these parameters is considered, with special reference to sampling, choice of detector material, detector ring diameter and shielding and variations in point spread function. Quantitation problems discussed are normalization, and attenuation and random corrections. Present developments mentioned are noise reduction through time-of-flight-assisted tomography and signal to noise improvements through high intrinsic resolution. Extensive bibliography. (U.K.)

  19. Use of a hand-held bladder ultrasound scanner in the assessment of dehydration and monitoring response to treatment in a paediatric emergency department.

    Science.gov (United States)

    Enright, Kevin; Beattie, Tom; Taheri, Sepideh

    2010-10-01

    Dehydration is a common concern in paediatric emergency care. Limited tools are available to assess reduced urine production, which is commonly cited as a reliable marker of dehydration. To evaluate the utility of a hand-held bladder ultrasound scanner in monitoring urine production in children attending the emergency department with suspected dehydration. A prospective pilot study was undertaken on a convenience sample of patients presenting with suspected dehydration. Serial bladder ultrasound scanning was performed to monitor urine output. Dehydration was assessed clinically using the WHO guide to dehydration assessment. Decisions about treatment and admission were made independently of the urine output measurements obtained using the bladder scanner. 45 children were studied. Using the WHO guide, 33 (73%) had mild dehydration, 8 (18%) had moderate dehydration and 4 (9%) had severe dehydration. There was a significant difference in estimated urine production between those admitted and those discharged (0.9±1.2 ml/kg/h vs 1.8±1.5 ml/kg/h, p=0.01) and between those with mild dehydration versus moderate/severe dehydration (2.3±1.5 ml/kg/h vs 0.6±0.7 ml/kg/h, p=0.0011). Urine output had been significantly reduced in those who had received an intravenous fluid bolus compared with those who had not (0.4±0.46 ml/kg/h vs 1.9±1.6 ml/kg/h, p=0.001). The hand-held bladder scanner is a convenient, non-invasive and objective adjunct in the assessment and management of children attending the emergency department with suspected dehydration.

  20. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1984-09-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  1. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1985-01-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  2. Hand-Held Sunphotometers for High School Student Construction and Measuring Aerosol Optical Thickness

    Science.gov (United States)

    Almonor, Linda; Baldwin, C.; Craig, R.; Johnson, L. P.

    2000-01-01

    Science education is taking the teaching of science from a traditional (lecture) approach to a multidimensional sense-making approach which allows teachers to support students by providing exploratory experiences. Using projects is one way of providing students with opportunities to observe and participate in sense-making activity. We created a learning environment that fostered inquiry-based learning. Students were engaged in a variety of Inquiry activities that enabled them to work in cooperative planning teams where respect for each other was encouraged and their ability to grasp, transform and transfer information was enhanced. Summer, 1998: An air pollution workshop was conducted for high school students in the Medgar Evers College/Middle College High School Liberty Partnership Summer Program. Students learned the basics of meteorology: structure and composition of the atmosphere and the processes that cause weather. The highlight of this workshop was the building of hand-held sunphotometers, which measure the intensity of the sunlight striking the Earth. Summer, 1999: high school students conducted a research project which measured the mass and size of ambient particulates and enhanced our ability to observe through land based measurements changes in the optical depth of ambient aerosols over Brooklyn. Students used hand held Sunphotometers to collect data over a two week period and entered it into the NASA GISS database by way of the internet.

  3. 3D indoor modeling using a hand-held embedded system with multiple laser range scanners

    Science.gov (United States)

    Hu, Shaoxing; Wang, Duhu; Xu, Shike

    2016-10-01

    Accurate three-dimensional perception is a key technology for many engineering applications, including mobile mapping, obstacle detection and virtual reality. In this article, we present a hand-held embedded system designed for constructing 3D representation of structured indoor environments. Different from traditional vehicle-borne mobile mapping methods, the system presented here is capable of efficiently acquiring 3D data while an operator carrying the device traverses through the site. It consists of a simultaneous localization and mapping(SLAM) module, a 3D attitude estimate module and a point cloud processing module. The SLAM is based on a scan matching approach using a modern LIDAR system, and the 3D attitude estimate is generated by a navigation filter using inertial sensors. The hardware comprises three 2D time-flight laser range finders and an inertial measurement unit(IMU). All the sensors are rigidly mounted on a body frame. The algorithms are developed on the frame of robot operating system(ROS). The 3D model is constructed using the point cloud library(PCL). Multiple datasets have shown robust performance of the presented system in indoor scenarios.

  4. Hand-Held Photometer for Instant On-Spot Quantification of Nucleic Acids, Proteins, and Cells.

    Science.gov (United States)

    Li, Shi-Hao; Jain, Abhinav; Tscharntke, Timo; Arnold, Tobias; Trau, Dieter W

    2018-02-20

    This paper presents a novel hand-held photometer, termed "Photopette", for on-spot absorbance measurements of biochemical analytes. The Photopette is a multicomponent, highly portable device with an overall weight of 160 g, which fits within 202 mm × 47 mm × 42 mm. Designed in the form factor of a micropipette, Photopette integrates a photodiode detector with light emitting diodes (LEDs) to form a highly customizable photometer which supports a wide variety of applications within the wavelengths between 260 and 1050 nm. A dual-purpose disposable reflective tip was designed to act as a sample holder and a light-reflecting system, which is in stark contrast to the operation of mainstream spectrophotometers and photometers. Small volume analytes may be measured with low sample loss using this proprietary CuveTip. A user-friendly software application running on smart devices was developed to control and read the values from Photopette via a low-energy Bluetooth link. This one-step strategy allows measurements on-spot without sample transfer, minimizing cross-contamination and human error. The results reported in this paper demonstrate Photopette's great potential to quantify DNA, direct protein, and cell density directly within the laminar flow hood. Results are compared with a Nanodrop 2000c spectrophotometer, a mainstream spectrophotometer for small-volume measurements.

  5. Handheld highly selective plasmonic chem/biosensor using engineered binding proteins for extreme conformational changes

    Science.gov (United States)

    Kosciolek, Derek J.; Sonar, Ajay; Lepak, Lori A.; Schnatz, Peter; Bendoym, Igor; Brown, Mia C.; Koder, Ronald L.; Crouse, David T.

    2017-08-01

    In this project we develop a handheld, portable, highly selective and sensitive chem/biosensor that has potential applications in both airborne and water-based environmental sensing. The device relies on a plasmonic chip of subwavelength-scale periodic gold rods engineered to resonate in the near infrared. The chip is functionalized with a novel class of proteins that exhibit large conformational changes upon binding to a specific target analyte. The subsequent change in local refractive index near the surface of the gold is one to two orders of magnitude greater than current conventional methods, which produces a readily measurable 5 to 10 percent difference in light transmission. This allows us to forgo traditional, bulky tabletop setups in favor of a compact form factor. Using commercially available optics to construct a transmission-based optical train, measured changes in bulk refractive index are presented here. While synthesis of binding protein efforts are focused on heme as analyte for proof of concept validation, the functionalized protein can be engineered to pair with a wide variety of analytes with minimal alterations to the plasmonic chip or device design. Such flexibility allows for this device to potentially meet the needs of first responders and health care professionals in a multitude of scenarios.

  6. Status of safeguards instrumentation

    International Nuclear Information System (INIS)

    Higinbotham, W.A.

    The International Atomic Energy Agency is performing safeguards at some nuclear power reactors, 50 bulk processing facilities, and 170 research facilities. Its verification activities require the use of instruments to measure nuclear materials and of surveillance instruments to maintain continuity of knowledge of the locations of nuclear materials. Instruments that are in use and under development to measure weight, volume, concentration, and isotopic composition of nuclear materials, and the major surveillance instruments, are described in connection with their uses at representative nuclear facilities. The current status of safeguards instrumentation and the needs for future development are discussed

  7. Early modern mathematical instruments.

    Science.gov (United States)

    Bennett, Jim

    2011-12-01

    In considering the appropriate use of the terms "science" and "scientific instrument," tracing the history of "mathematical instruments" in the early modern period is offered as an illuminating alternative to the historian's natural instinct to follow the guiding lights of originality and innovation, even if the trail transgresses contemporary boundaries. The mathematical instrument was a well-defined category, shared across the academic, artisanal, and commercial aspects of instrumentation, and its narrative from the sixteenth to the eighteenth century was largely independent from other classes of device, in a period when a "scientific" instrument was unheard of.

  8. Instrumental Capital

    Directory of Open Access Journals (Sweden)

    Gabriel Valerio

    2007-07-01

    Full Text Available During the history of human kind, since our first ancestors, tools have represented a mean to reach objectives which might otherwise seemed impossibles. In the called New Economy, where tangibles assets appear to be losing the role as the core element to produce value versus knowledge, tools have kept aside man in his dairy work. In this article, the author's objective is to describe, in a simple manner, the importance of managing the organization's group of tools or instruments (Instrumental Capital. The characteristic conditions of this New Economy, the way Knowledge Management deals with these new conditions and the sub-processes that provide support to the management of Instrumental Capital are described.

  9. Evaluating musical instruments

    International Nuclear Information System (INIS)

    Campbell, D. Murray

    2014-01-01

    Scientific measurements of sound generation and radiation by musical instruments are surprisingly hard to correlate with the subtle and complex judgments of instrumental quality made by expert musicians

  10. A Mixed-Methods, Randomized, Controlled Feasibility Trial to Inform the Design of a Phase III Trial to Test the Effect of the Handheld Fan on Physical Activity and Carer Anxiety in Patients With Refractory Breathlessness.

    Science.gov (United States)

    Johnson, Miriam J; Booth, Sara; Currow, David C; Lam, Lawrence T; Phillips, Jane L

    2016-05-01

    The handheld fan is an inexpensive and safe way to provide facial airflow, which may reduce the sensation of chronic refractory breathlessness, a frequently encountered symptom. To test the feasibility of developing an adequately powered, multicenter, multinational randomized controlled trial comparing the efficacy of a handheld fan and exercise advice with advice alone in increasing activity in people with chronic refractory breathlessness from a variety of medical conditions, measuring recruitment rates; data quality; and potential primary outcome measures. This was a Phase II, multisite, international, parallel, nonblinded, mixed-methods randomized controlled trial. Participants were centrally randomized to fan or control. All received breathlessness self-management/exercise advice and were followed up weekly for four weeks. Participants/carers were invited to participate in a semistructured interview at the study's conclusion. Ninety-seven people were screened, 49 randomized (mean age 68 years; 49% men), and 43 completed the study. Site recruitment varied from 0.25 to 3.3/month and screening:randomization from 1.1:1 to 8.5:1. There were few missing data except for the Chronic Obstructive Pulmonary Disease Self-Efficacy Scale (two-thirds of data missing). No harms were observed. Three interview themes included 1) a fan is a helpful self-management strategy, 2) a fan aids recovery, and 3) a symptom control trial was welcome. A definitive, multisite trial to study the use of the handheld fan as part of self-management of chronic refractory breathlessness is feasible. Participants found the fan useful. However, the value of information for changing practice or policy is unlikely to justify the expense of such a trial, given perceived benefits, the minimal costs, and an absence of harms demonstrated in this study. Copyright © 2016 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  11. Instrument Modeling and Synthesis

    Science.gov (United States)

    Horner, Andrew B.; Beauchamp, James W.

    During the 1970s and 1980s, before synthesizers based on direct sampling of musical sounds became popular, replicating musical instruments using frequency modulation (FM) or wavetable synthesis was one of the “holy grails” of music synthesis. Synthesizers such as the Yamaha DX7 allowed users great flexibility in mixing and matching sounds, but were notoriously difficult to coerce into producing sounds like those of a given instrument. Instrument design wizards practiced the mysteries of FM instrument design.

  12. Instrumentation for Nuclear Applications

    International Nuclear Information System (INIS)

    1998-01-01

    The objective of this project was to develop and coordinate nuclear instrumentation standards with resulting economies for the nuclear and radiation fields. There was particular emphasis on coordination and management of the Nuclear Instrument Module (NIM) System, U.S. activity involving the CAMAC international standard dataway system, the FASTBUS modular high-speed data acquisition and control system and processing and management of national nuclear instrumentation and detector standards, as well as a modest amount of assistance and consultation services to the Pollutant Characterization and Safety Research Division of the Office of Health and Environmental Research. The principal accomplishments were the development and maintenance of the NIM instrumentation system that is the predominant instrumentation system in the nuclear and radiation fields worldwide, the CAMAC digital interface system in coordination with the ESONE Committee of European Laboratories, the FASTBUS high-speed system and numerous national and international nuclear instrumentation standards

  13. On Representative Spaceflight Instrument and Associated Instrument Sensor Web Framework

    Science.gov (United States)

    Kizhner, Semion; Patel, Umeshkumar; Vootukuru, Meg

    2007-01-01

    Sensor Web-based adaptation and sharing of space flight mission resources, including those of the Space-Ground and Control-User communication segment, could greatly benefit from utilization of heritage Internet Protocols and devices applied for Spaceflight (SpaceIP). This had been successfully demonstrated by a few recent spaceflight experiments. However, while terrestrial applications of Internet protocols are well developed and understood (mostly due to billions of dollars in investments by the military and industry), the spaceflight application of Internet protocols is still in its infancy. Progress in the developments of SpaceIP-enabled instrument components will largely determine the SpaceIP utilization of those investments and acceptance in years to come. Likewise SpaceIP, the development of commercial real-time and instrument colocated computational resources, data compression and storage, can be enabled on-board a spacecraft and, in turn, support a powerful application to Sensor Web-based design of a spaceflight instrument. Sensor Web-enabled reconfiguration and adaptation of structures for hardware resources and information systems will commence application of Field Programmable Arrays (FPGA) and other aerospace programmable logic devices for what this technology was intended. These are a few obvious potential benefits of Sensor Web technologies for spaceflight applications. However, they are still waiting to be explored. This is because there is a need for a new approach to spaceflight instrumentation in order to make these mature sensor web technologies applicable for spaceflight. In this paper we present an approach in developing related and enabling spaceflight instrument-level technologies based on the new concept of a representative spaceflight Instrument Sensor Web (ISW).

  14. Virtual instrumentation: a new approach for control and instrumentation - application in containment studies facility

    International Nuclear Information System (INIS)

    Gole, N.V.; Shanware, V.M.; Sebastian, A.; Subramaniam, K.

    2001-01-01

    PC based data-acquisition has emerged as a rapidly developing area particularly with respect to process instrumentation. Computer based data acquisition in process instrumentation combined with Supervisory Control and Data Acquisition (SCADA) software has introduced extensive possibilities with respect to formats for presentation of information. The concept of presenting data using any instrument format with the help of software tools to simulate the instrument on screen, needs to be understood, in order to be able to make use of its vast potential. The purpose of this paper is to present the significant features of the Virtual Instrumentation concept and discuss its application in the instrumentation and control system of containment studies facility (CSF). Factors involved in the development of the virtual instrumentation based I and C system for CSF are detailed and a functional overview of the system configuration is given. (author)

  15. Compact handheld low-cost biosensor platform for remote health monitoring

    Science.gov (United States)

    Hastanin, J.; Lenaerts, C.; Gailly, P.; Jans, H.; Huang, C.; Lagae, L.; Kokkinos, D.; Fleury-Frenette, K.

    2016-04-01

    In this paper, we present an original concept of plasmonic-related instrumentation platform dedicated to diagnostic biosensing tests out of the laboratory. The developed instrumental platform includes both disposable one-use microfluidic affinity biochip and compact optical readout device for biochip monitoring involving mobile Internet devices for data processing and communication. The biochip includes both microfluidic and optical coupling structures formed into a single plastic slab. The microfluidic path of the biochip operates in passive capillary pumping mode. In the proof-of-concept prototype, we address specifically the sensing format involving Surface Plasmon Resonance phenomenon. The biochip is plugged in the readout device without the use of an index matching fluid. An essential advantage of the developed biochip is that its implementation involves conventional hot embossing and thin film deposition process, perfectly suited for mass production of low-cost microfluidic biochip for biochemical applications.

  16. LOFT instrumentation

    International Nuclear Information System (INIS)

    Bixby, W.W.

    1979-01-01

    A description of instrumentation used in the Loss-of-Fluid Test (LOFT) large break Loss-of-Coolant Experiments is presented. Emphasis is placed on hydraulic and thermal measurements in the primary system piping and components, reactor vessel, and pressure suppression system. In addition, instrumentation which is being considered for measurement of phenomena during future small break testing is discussed. (orig.) 891 HP/orig. 892 BRE [de

  17. FRMAC Updates

    International Nuclear Information System (INIS)

    Mueller, P.

    1995-01-01

    This talks describes updates in the following updates in FRMAC publications concerning radiation emergencies: Monitoring and Analysis Manual; Evaluation and Assessment Manual; Handshake Series (Biannual) including exercises participated in; environmental Data and Instrument Transmission System (EDITS); Plume in a Box with all radiological data stored onto a hand-held computer; and courses given

  18. Instrumentation for environmental monitoring: biomedical

    International Nuclear Information System (INIS)

    1979-05-01

    An update is presented to Volume four of the six-volume series devoted to a survey of instruments useful for measurements in biomedicine related to environmental research and monitoring. Results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Methods of detection and analysis of gaseous organic pollutants and metals, including Ni and As are presented. Instrument techniques and notes are included on atomic spectrometry and uv and visible absorption instrumentation

  19. Aeroacoustics of Musical Instruments

    NARCIS (Netherlands)

    Fabre, B.; Gilbert, J.; Hirschberg, Abraham; Pelorson, X.

    2012-01-01

    We are interested in the quality of sound produced by musical instruments and their playability. In wind instruments, a hydrodynamic source of sound is coupled to an acoustic resonator. Linear acoustics can predict the pitch of an instrument. This can significantly reduce the trial-and-error process

  20. Isotope-equipped measuring instruments

    International Nuclear Information System (INIS)

    Miyagawa, Kazuo; Amano, Hiroshi

    1980-01-01

    In the steel industry, though the investment in isotope-equipped measuring instruments is small as compared with that in machinery, they play important role in the moisture measurement in sintering and blast furnaces, the thickness measurement in rolling process and others in automatic control systems. The economic aspect of the isotope-equipped measuring instruments is described on the basis of the practices in Kimitsu Works of Nippon Steel Corporation: distribution of such instruments, evaluation of economic effects, usefulness evaluation in view of raising the accuracy, and usefulness evaluation viewed from the failure of the isotope instruments. The evaluation of economic effects was made under the premise that the isotope-equipped measuring instruments are not employed. Then, the effects of raising the accuracy are evaluated for a γ-ray plate thickness gauge and a neutron moisture gauge for coke in a blast furnace. Finally, the usefulness was evaluated, assuming possible failure of the isotope-equipped measuring instruments. (J.P.N.)

  1. Instrumentation reference book

    CERN Document Server

    Boyes, Walt

    2002-01-01

    Instrumentation is not a clearly defined subject, having a 'fuzzy' boundary with a number of other disciplines. Often categorized as either 'techniques' or 'applications' this book addresses the various applications that may be needed with reference to the practical techniques that are available for the instrumentation or measurement of a specific physical quantity or quality. This makes it of direct interest to anyone working in the process, control and instrumentation fields where these measurements are essential.* Comprehensive and authoritative collection of technical information* Writte

  2. Jones' instrument technology

    CERN Document Server

    Jones, Ernest Beachcroft; Kingham, Edward G; Radnai, Rudolf

    1985-01-01

    Jones' Instrument Technology, Volume 5: Automatic Instruments and Measuring Systems deals with general trends in automatic instruments and measuring systems. Specific examples are provided to illustrate the principles of such devices. A brief review of a considerable number of standards is undertaken, with emphasis on the IEC625 Interface System. Other relevant standards are reviewed, including the interface and backplane bus standards. This volume is comprised of seven chapters and begins with a short introduction to the principles of automatic measurements, classification of measuring system

  3. The use of handheld GPS to determine tidal slack in estuaries

    Science.gov (United States)

    Lievens, M.; Savenije, H.; Luxemburg, W.

    2010-12-01

    The phase lag between the moment of high water and high water slack, respectively low water and low water slack, is a key parameter in tidal hydraulics which is often disregarded. Savenije (1992) found that there are simple analytical relations for estuary topography, wave celerity and phase lag, that can be derived from the equation for conservation of mass and momentum. At present, methods to determine the phase lag by measuring the moment of tidal slack in the field are often either inadequate or very expensive. To be sure if assumptions made for the analytical derivation are acceptable, measuring the ‘real’ moment of tidal slack in the field is necessary. The method to determine the exact moment of tidal slack, developed in this work, is based on the use of a simple handheld GPS at some locations in the Dutch part of the Scheldt estuary. The GPS device is attached to a shipping lane buoy, which is fixed to the bottom of the estuary with a long chain. The chain gives the buoy enough space for an amplitude of approximately 25 - 30 meters. The GPS device measures the location of the buoy every 30 seconds for a few days. The data from the GPS results in a nice view of the path that the buoy travelled. The moment that the buoy switches direction, should be the moment of tidal slack. The “GPS method” of measuring the phase lag would allow application on full estuary scale in the future. Besides that, we get more insight in the key parameter of slack times for tidal hydraulics. The results are also of key importance to commercial shipping, towage and salvage companies and other users of estuaries worldwide.

  4. In-Season Yield Prediction of Cabbage with a Hand-Held Active Canopy Sensor.

    Science.gov (United States)

    Ji, Rongting; Min, Ju; Wang, Yuan; Cheng, Hu; Zhang, Hailin; Shi, Weiming

    2017-10-08

    Efficient and precise yield prediction is critical to optimize cabbage yields and guide fertilizer application. A two-year field experiment was conducted to establish a yield prediction model for cabbage by using the Greenseeker hand-held optical sensor. Two cabbage cultivars (Jianbao and Pingbao) were used and Jianbao cultivar was grown for 2 consecutive seasons but Pingbao was only grown in the second season. Four chemical nitrogen application rates were implemented: 0, 80, 140, and 200 kg·N·ha -1 . Normalized difference vegetation index (NDVI) was collected 20, 50, 70, 80, 90, 100, 110, 120, 130, and 140 days after transplanting (DAT). Pearson correlation analysis and regression analysis were performed to identify the relationship between the NDVI measurements and harvested yields of cabbage. NDVI measurements obtained at 110 DAT were significantly correlated to yield and explained 87-89% and 75-82% of the cabbage yield variation of Jianbao cultivar over the two-year experiment and 77-81% of the yield variability of Pingbao cultivar. Adjusting the yield prediction models with CGDD (cumulative growing degree days) could make remarkable improvement to the accuracy of the prediction model and increase the determination coefficient to 0.82, while the modification with DFP (days from transplanting when GDD > 0) values did not. The integrated exponential yield prediction equation was better than linear or quadratic functions and could accurately make in-season estimation of cabbage yields with different cultivars between years.

  5. Diagnostic accuracy of fundal height and handheld ultrasound-measured abdominal circumference to screen for fetal growth abnormalities

    Science.gov (United States)

    Haragan, Adriane F.; Hulsey, Thomas C.; Hawk, Angela F.; Newman, Roger B.; Chang, Eugene Y.

    2015-01-01

    OBJECTIVE We sought to compare fundal height and handheld ultrasound–measured fetal abdominal circumference (HHAC) for the prediction of fetal growth restriction (FGR) or large for gestational age. STUDY DESIGN This was a diagnostic accuracy study in nonanomalous singleton pregnancies between 24 and 40 weeks’ gestation. Patients underwent HHAC and fundal height measurement prior to formal growth ultrasound. FGR was defined as estimated fetal weight less than 10%, whereas large for gestational age was defined as estimated fetal weight greater than 90%. Sensitivity and specificity were calculated and compared using methods described elsewhere. RESULTS There were 251 patients included in this study. HHAC had superior sensitivity and specificity for the detection of FGR (sensitivity, 100% vs 42.86%) and (specificity, 92.62% vs 85.24%). HHAC had higher specificity but lower sensitivity when screening for LGA (specificity, 85.66% vs 66.39%) and (sensitivity, 57.14% vs 71.43%). CONCLUSION HHAC could prove to be a valuable screening tool in the detection of FGR. Further studies are needed in a larger population. PMID:25818672

  6. Four dimensional hybrid ultrasound and optoacoustic imaging via passive element optical excitation in a hand-held probe

    Science.gov (United States)

    Fehm, Thomas Felix; Deán-Ben, Xosé Luís; Razansky, Daniel

    2014-10-01

    Ultrasonography and optoacoustic imaging share powerful advantages related to the natural aptitude for real-time image rendering with high resolution, the hand-held operation, and lack of ionizing radiation. The two methods also possess very different yet highly complementary advantages of the mechanical and optical contrast in living tissues. Nonetheless, efficient integration of these modalities remains challenging owing to the fundamental differences in the underlying physical contrast, optimal signal acquisition, and image reconstruction approaches. We report on a method for hybrid acquisition and reconstruction of three-dimensional pulse-echo ultrasound and optoacoustic images in real time based on passive ultrasound generation with an optical absorber, thus avoiding the hardware complexity of active ultrasound generation. In this way, complete hybrid datasets are generated with a single laser interrogation pulse, resulting in simultaneous rendering of ultrasound and optoacoustic images at an unprecedented rate of 10 volumetric frames per second. Performance is subsequently showcased in phantom experiments and in-vivo measurements from a healthy human volunteer, confirming general clinical applicability of the method.

  7. Four dimensional hybrid ultrasound and optoacoustic imaging via passive element optical excitation in a hand-held probe

    International Nuclear Information System (INIS)

    Fehm, Thomas Felix; Razansky, Daniel; Deán-Ben, Xosé Luís

    2014-01-01

    Ultrasonography and optoacoustic imaging share powerful advantages related to the natural aptitude for real-time image rendering with high resolution, the hand-held operation, and lack of ionizing radiation. The two methods also possess very different yet highly complementary advantages of the mechanical and optical contrast in living tissues. Nonetheless, efficient integration of these modalities remains challenging owing to the fundamental differences in the underlying physical contrast, optimal signal acquisition, and image reconstruction approaches. We report on a method for hybrid acquisition and reconstruction of three-dimensional pulse-echo ultrasound and optoacoustic images in real time based on passive ultrasound generation with an optical absorber, thus avoiding the hardware complexity of active ultrasound generation. In this way, complete hybrid datasets are generated with a single laser interrogation pulse, resulting in simultaneous rendering of ultrasound and optoacoustic images at an unprecedented rate of 10 volumetric frames per second. Performance is subsequently showcased in phantom experiments and in-vivo measurements from a healthy human volunteer, confirming general clinical applicability of the method.

  8. Four dimensional hybrid ultrasound and optoacoustic imaging via passive element optical excitation in a hand-held probe

    Energy Technology Data Exchange (ETDEWEB)

    Fehm, Thomas Felix; Razansky, Daniel, E-mail: dr@tum.de [Institute for Biological and Medical Imaging (IBMI), Helmholtz Zentrum München, Neuherberg (Germany); Faculty of Medicine, Technische Universität München, Munich (Germany); Deán-Ben, Xosé Luís [Institute for Biological and Medical Imaging (IBMI), Helmholtz Zentrum München, Neuherberg (Germany)

    2014-10-27

    Ultrasonography and optoacoustic imaging share powerful advantages related to the natural aptitude for real-time image rendering with high resolution, the hand-held operation, and lack of ionizing radiation. The two methods also possess very different yet highly complementary advantages of the mechanical and optical contrast in living tissues. Nonetheless, efficient integration of these modalities remains challenging owing to the fundamental differences in the underlying physical contrast, optimal signal acquisition, and image reconstruction approaches. We report on a method for hybrid acquisition and reconstruction of three-dimensional pulse-echo ultrasound and optoacoustic images in real time based on passive ultrasound generation with an optical absorber, thus avoiding the hardware complexity of active ultrasound generation. In this way, complete hybrid datasets are generated with a single laser interrogation pulse, resulting in simultaneous rendering of ultrasound and optoacoustic images at an unprecedented rate of 10 volumetric frames per second. Performance is subsequently showcased in phantom experiments and in-vivo measurements from a healthy human volunteer, confirming general clinical applicability of the method.

  9. Prevalence and risk factors associated with musculoskeletal complaints among users of mobile handheld devices: A systematic review.

    Science.gov (United States)

    Xie, Yanfei; Szeto, Grace; Dai, Jie

    2017-03-01

    This systematic review aimed at evaluating the prevalence and risk factors for musculoskeletal complaints associated with mobile handheld device use. Pubmed, Medline, Web of Science, CINAHL and Embase were searched. The methodological quality of included studies was assessed. Strength of evidence for risk factors was determined based on study designs, methodological quality and consistency of results. Five high-quality, eight acceptable-quality and two low-quality peer-reviewed articles were included. This review demonstrates that the prevalence of musculoskeletal complaints among mobile device users ranges from 1.0% to 67.8% and neck complaints have the highest prevalence rates ranging from 17.3% to 67.8%. This study also finds some evidence for neck flexion, frequency of phone calls, texting and gaming in relation to musculoskeletal complaints among mobile device users. Inconclusive evidence is shown for other risk factors such as duration of use and human-device interaction techniques due to inconsistent results or a limited number of studies. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Astronomical Instrumentation System Markup Language

    Science.gov (United States)

    Goldbaum, Jesse M.

    2016-05-01

    The Astronomical Instrumentation System Markup Language (AISML) is an Extensible Markup Language (XML) based file format for maintaining and exchanging information about astronomical instrumentation. The factors behind the need for an AISML are first discussed followed by the reasons why XML was chosen as the format. Next it's shown how XML also provides the framework for a more precise definition of an astronomical instrument and how these instruments can be combined to form an Astronomical Instrumentation System (AIS). AISML files for several instruments as well as one for a sample AIS are provided. The files demonstrate how AISML can be utilized for various tasks from web page generation and programming interface to instrument maintenance and quality management. The advantages of widespread adoption of AISML are discussed.

  11. Soil monitoring instrumentation

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1981-01-01

    The Los Alamos Scientific Laboratory (LASL) has an extensive program for the development of nondestructive assay instrumentation for the quantitative analysis of transuranic (TRU) materials found in bulk solid wastes generated by Department of Energy facilities and by the commercial nuclear power industry. Included are wastes generated in decontamination and decommissioning of outdated nuclear facilities, as well as from old waste-burial-ground exhumation programs. The assay instrumentation is designed to have detection limits below 10 nCi/g wherever practicable. The assay instrumentation that is applied specifically to soil monitoring is discussed

  12. Instruments to assess integrated care

    DEFF Research Database (Denmark)

    Lyngsø, Anne Marie; Godtfredsen, Nina Skavlan; Høst, Dorte

    2014-01-01

    INTRODUCTION: Although several measurement instruments have been developed to measure the level of integrated health care delivery, no standardised, validated instrument exists covering all aspects of integrated care. The purpose of this review is to identify the instruments concerning how to mea...... was prevalent. It is uncertain whether development of a single 'all-inclusive' model for assessing integrated care is desirable. We emphasise the continuing need for validated instruments embedded in theoretical contexts.......INTRODUCTION: Although several measurement instruments have been developed to measure the level of integrated health care delivery, no standardised, validated instrument exists covering all aspects of integrated care. The purpose of this review is to identify the instruments concerning how...... to measure the level of integration across health-care sectors and to assess and evaluate the organisational elements within the instruments identified. METHODS: An extensive, systematic literature review in PubMed, CINAHL, PsycINFO, Cochrane Library, Web of Science for the years 1980-2011. Selected...

  13. Analysis on detection accuracy of binocular photoelectric instrument optical axis parallelism digital calibration instrument

    Science.gov (United States)

    Ying, Jia-ju; Yin, Jian-ling; Wu, Dong-sheng; Liu, Jie; Chen, Yu-dan

    2017-11-01

    Low-light level night vision device and thermal infrared imaging binocular photoelectric instrument are used widely. The maladjustment of binocular instrument ocular axises parallelism will cause the observer the symptom such as dizziness, nausea, when use for a long time. Binocular photoelectric equipment digital calibration instrument is developed for detecting ocular axises parallelism. And the quantitative value of optical axis deviation can be quantitatively measured. As a testing instrument, the precision must be much higher than the standard of test instrument. Analyzes the factors that influence the accuracy of detection. Factors exist in each testing process link which affect the precision of the detecting instrument. They can be divided into two categories, one category is factors which directly affect the position of reticle image, the other category is factors which affect the calculation the center of reticle image. And the Synthesize error is calculated out. And further distribute the errors reasonably to ensure the accuracy of calibration instruments.

  14. Hand-held triangulation laser profilometer with audio output for blind people Profilométre laser à triangulation tenu en main avec sortie sonare pour non-voyants

    Science.gov (United States)

    Farcy, R.; Damaschini, R.

    1998-06-01

    We describe a device currently under industrial development which will give to the blind a means of three-dimensional space perception. It consists of a 350 g hand-held triangulating laser telemeter including electronic parts and batteries, with auditory feedback either inside the apparatus or close to the ear. The microprocessor unit converts in real time the distance measured by the telemeter into a musical note. Scanning the space with an adequate movement of the hand produces musical lines corresponding to the profiles of the environment. We discuss the optical configuration of the system relative to our first year of clinical experimentation.

  15. A-KAM, bracket positioning device

    Directory of Open Access Journals (Sweden)

    Anand Ambekar

    2018-01-01

    Full Text Available Bracket positioning is the heart of preadjusted edgewise appliance. Accuracy of bracket positioning directly affects the treatment outcome. A number of hand-held instruments are available for bracket positioning accuracy including Boon's gauge, MBT gauges, and various other modifications. However, the most commonly used MBT gauges come in a set of two or four jigs with gauges on each end of the instrument making it difficult to carry in the instrument tray for the orthodontists. Our new bracket positioning instrument, A-KAM, bracket positioning device surpasses these difficulties and can be used for reproducible bracket placement from 2.5 mm to 5.5 mm from the base of bracket.

  16. [Controlling instruments in radiology].

    Science.gov (United States)

    Maurer, M

    2013-10-01

    Due to the rising costs and competitive pressures radiological clinics and practices are now facing, controlling instruments are gaining importance in the optimization of structures and processes of the various diagnostic examinations and interventional procedures. It will be shown how the use of selected controlling instruments can secure and improve the performance of radiological facilities. A definition of the concept of controlling will be provided. It will be shown which controlling instruments can be applied in radiological departments and practices. As an example, two of the controlling instruments, material cost analysis and benchmarking, will be illustrated.

  17. Analysis of instrumentation technology for SMART

    International Nuclear Information System (INIS)

    Hur, Seop; Koo, I. S.; Park, H. Y.; Lee, C. K.; Kim, D. H.; Suh, Y. S.; Seong, S. H.; Jang, G. S.

    1998-03-01

    It is necessary that development requirements, techniques to be developed, and development tasks and approach are established to develop the SMART instrumentation system. It is important to establish the development strategies for input for developing SMART instrumentation system. To meet above needs, the industry general and nuclear instrumentation techniques were analyzed and reviewed, respectively, based on the classification of instrumentation to analyze the industrial instrumentation techniques, and analysis results which described the inherent merits and demerits of each technique can be used for inputs to select the instruments for SMART. For the instrumentation techniques for nuclear environments, the major instrumentation techniques were reviewed, and the instrumentation system were established. The following development approaches were established based on the development requirements and the analysis results of research and development trends of industrial and nuclear instrumentation techniques. (author). 90 refs., 38 tabs., 33 figs

  18. An Attitude Scale on Individual Instrument and Individual Instrument Course: Validity-Reliability Research

    Science.gov (United States)

    Kuçukosmanoglu, Hayrettin Onur

    2015-01-01

    The main purpose of this study is to develop a scale to determine students' attitude levels on individual instruments and individual instrument courses in instrument training, which is an important dimension of music education, and to conduct a validity-reliability research of the scale that has been developed. The scale consists of 16 items. The…

  19. A fully integrated UHF RFID reader SoC for handheld applications in the 0.18 {mu}m CMOS process

    Energy Technology Data Exchange (ETDEWEB)

    Wang Jingchao; Zhang Chun; Wang Zhihua, E-mail: wangjc@gmail.co [Institute of Microelectronics, Tsinghua University, Beijing 100084 (China)

    2010-08-15

    A low cost fully integrated single-chip UHF radio frequency identification (RFID) reader SoC for short distance handheld applications is presented. The SoC integrates all building blocks-including an RF transceiver, a PLL frequency synthesizer, a digital baseband and an MCU-in a 0.18 {mu}m CMOS process. A high-linearity RX front-end is designed to handle the large self-interferer. A class-E power amplifier with high power efficiency is also integrated to fulfill the function of a UHF passive RFID reader. The measured maximum output power of the transmitter is 20.28 dBm and the measured receiver sensitivity is -60 dBm. The digital baseband including MCU core consumes 3.91 mW with a clock of 10 MHz and the analog part including power amplifier consumes 368.4 mW. The chip has a die area of 5.1 x 3.8 mm{sup 2} including pads. (semiconductor integrated circuits)

  20. A fully integrated UHF RFID reader SoC for handheld applications in the 0.18 μm CMOS process

    International Nuclear Information System (INIS)

    Wang Jingchao; Zhang Chun; Wang Zhihua

    2010-01-01

    A low cost fully integrated single-chip UHF radio frequency identification (RFID) reader SoC for short distance handheld applications is presented. The SoC integrates all building blocks-including an RF transceiver, a PLL frequency synthesizer, a digital baseband and an MCU-in a 0.18 μm CMOS process. A high-linearity RX front-end is designed to handle the large self-interferer. A class-E power amplifier with high power efficiency is also integrated to fulfill the function of a UHF passive RFID reader. The measured maximum output power of the transmitter is 20.28 dBm and the measured receiver sensitivity is -60 dBm. The digital baseband including MCU core consumes 3.91 mW with a clock of 10 MHz and the analog part including power amplifier consumes 368.4 mW. The chip has a die area of 5.1 x 3.8 mm 2 including pads. (semiconductor integrated circuits)

  1. Development of a low cost, GPS-based upgrade to a standard handheld gamma detector for mapping environmental radioactive contamination

    International Nuclear Information System (INIS)

    Paridaens, J.

    2006-01-01

    A low cost extension to a standard handheld radiation monitor was developed, allowing one to perform outdoor georeferenced gamma measurements. It consists of a commercial wireless Bluetooth[reg] GPS receiver, a commercial RS-232 to Bluetooth[reg] converter combined with a standard Bluetooth[reg] enabled pocket personal computer (PPC). The system is intended for use in difficult to access areas, typically for foot campaigns. As the operator walks, a straightforward homemade visual basic program alternately reads GPS position and gamma dose rate into the PPC, creating a data log. This allows a single operator on foot to map between 50 and 200 ha of environmental radiation per day in very rugged areas, depending on the accessibility of the terrain and the detail required. On a test field with known contamination, a spatial precision of about 5-10 m was obtainable. The device was also used to reveal complex contamination patterns in the flooding zones of a radioactively contaminated small river

  2. Development of a low cost, GPS-based upgrade to a standard handheld gamma detector for mapping environmental radioactive contamination.

    Science.gov (United States)

    Paridaens, J

    2006-02-01

    A low cost extension to a standard handheld radiation monitor was developed, allowing one to perform outdoor georeferenced gamma measurements. It consists of a commercial wireless Bluetooth GPS receiver, a commercial RS-232 to Bluetooth converter combined with a standard Bluetooth enabled pocket personal computer (PPC). The system is intended for use in difficult to access areas, typically for foot campaigns. As the operator walks, a straightforward homemade visual basic program alternately reads GPS position and gamma dose rate into the PPC, creating a data log. This allows a single operator on foot to map between 50 and 200 ha of environmental radiation per day in very rugged areas, depending on the accessibility of the terrain and the detail required. On a test field with known contamination, a spatial precision of about 5-10 m was obtainable. The device was also used to reveal complex contamination patterns in the flooding zones of a radioactively contaminated small river.

  3. Development of a low cost, GPS-based upgrade to a standard handheld gamma detector for mapping environmental radioactive contamination

    Energy Technology Data Exchange (ETDEWEB)

    Paridaens, J. [Belgian Nuclear Research Centre, SCK.CEN, Boeretang 200, B2400 Mol (Belgium)]. E-mail: jparidae@sckcen.be

    2006-02-15

    A low cost extension to a standard handheld radiation monitor was developed, allowing one to perform outdoor georeferenced gamma measurements. It consists of a commercial wireless Bluetooth[reg] GPS receiver, a commercial RS-232 to Bluetooth[reg] converter combined with a standard Bluetooth[reg] enabled pocket personal computer (PPC). The system is intended for use in difficult to access areas, typically for foot campaigns. As the operator walks, a straightforward homemade visual basic program alternately reads GPS position and gamma dose rate into the PPC, creating a data log. This allows a single operator on foot to map between 50 and 200 ha of environmental radiation per day in very rugged areas, depending on the accessibility of the terrain and the detail required. On a test field with known contamination, a spatial precision of about 5-10 m was obtainable. The device was also used to reveal complex contamination patterns in the flooding zones of a radioactively contaminated small river.

  4. Power station instrumentation

    International Nuclear Information System (INIS)

    Jervis, M.W.

    1993-01-01

    Power stations are characterized by a wide variety of mechanical and electrical plant operating with structures, liquids and gases working at high pressures and temperatures and with large mass flows. The voltages and currents are also the highest that occur in most industries. In order to achieve maximum economy, the plant is operated with relatively small margins from conditions that can cause rapid plant damage, safety implications, and very high financial penalties. In common with other process industries, power stations depend heavily on control and instrumentation. These systems have become particularly significant, in the cost-conscious privatized environment, for providing the means to implement the automation implicit in maintaining safety standards, improving generation efficiency and reducing operating manpower costs. This book is for professional instrumentation engineers who need to known about their use in power stations and power station engineers requiring information about the principles and choice of instrumentation available. There are 8 chapters; chapter 4 on instrumentation for nuclear steam supply systems is indexed separately. (Author)

  5. The Science of String Instruments

    CERN Document Server

    Rossing, Thomas D

    2010-01-01

    Many performing musicians, as well as instrument builders, are coming to realize the importance of understanding the science of musical instruments. This book explains how string instruments produce sound. It presents basic ideas in simple language, and it also translates some more sophisticated ideas in non-technical language. It should be of interest to performers, researchers, and instrument makers alike.

  6. Instrumental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-15

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  7. Instrumental analysis

    International Nuclear Information System (INIS)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-01

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  8. Soil monitoring instrumentation

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1980-01-01

    The Los Alamos Scientific Laboratory (LASL) has an extensive program for the development of nondestructive assay instrumentation for the quantitative analysis of transuranic (TRU) materials found in bulk solid wastes generated by Department of Energy facilities and by the commercial nuclear power industry. Included are wastes generated in decontamination and decommissioning of outdated nuclear facilities as well as wastes from old waste burial ground exhumation programs. The assay instrumentation is designed to have detection limits below 10 nCi/g wherever practicable. Because of the topic of this workshop, only the assay instrumentation applied specifically to soil monitoring will be discussed here. Four types of soil monitors are described

  9. Radiation protection instrument 1993

    International Nuclear Information System (INIS)

    1993-04-01

    The Radiation Protection Instrument, 1993 (Legislative Instrument 1559) prescribes the powers and functions of the Radiation Protection Board established under the Ghana Atomic Energy Commission by the Atomic Energy Commission (Amendment) Law, 1993 (P.N.D.C. Law 308). Also included in the Legislative Instrument are schedules on control and use of ionising radiation and radiation sources as well as procedures for notification, licensing and inspection of ionising radiation facilities. (EAA)

  10. X-ray film digitization using a personal computer and hand-held scanner: a simple technique for storing images

    International Nuclear Information System (INIS)

    Munoz-Nunez, C. F.; Lloret-Alcaniz, A.

    1998-01-01

    To develop a simple, low-cost technique for the digitization of X-ray films for personal use. A 66-MHz 486 PC with 8 MB of RAM, a Logitech ScanMan 256 hand-held scanner and a standard negatoscope with the power source converted to direct current. Although the system was originally designed for the digitization of mammographies, it has also been used with computed tomography, magnetic resonance, digital angiography and ultrasonographic images, as well as plain X-rays. After a minimal training period, the system digitized X-ray films easily and rapidly. Although the scanning values vary depending on the type of image to be digitized, an input spatial resolution of 200 dpi and a contrast resolution of 256 levels of gray are generally adequate. Of the storage formats tested, JPEG presented the best quality/image size ratio. A simple, low-cost technique has been developed for the digitization of X-ray films. This technique enables the storage of images in a digital format, thus facilitating their presentation and transmission. (Author) 9 refs

  11. Handheld colorimeter for determination of heavy metal concentrations

    Science.gov (United States)

    López Ruiz, N.; Ariza, M.; Martínez Olmos, A.; Vukovic, J.; Palma, A. J.; Capitan-Vallvey, L. F.

    2011-08-01

    A portable instrument that measures heavy metal concentration from a colorimetric sensor array is presented. The use of eight sensing membranes, placed on a plastic support, allows to obtain the hue component of the HSV colour space of each one in order to determinate the concentration of metals present in a solution. The developed microcontroller-based system captures, in an ambient light environment, an image of the sensor array using an integrated micro-camera and shows the picture in a touch micro-LCD screen which acts as user interface. After image-processing of the regions of interest selected by the user, colour and concentration information are displayed on the screen.

  12. Handheld colorimeter for determination of heavy metal concentrations

    International Nuclear Information System (INIS)

    Lopez Ruiz, N; Martinez Olmos, A; Palma, A J; Ariza, M; Capitan-Vallvey, L F; Vukovic, J

    2011-01-01

    A portable instrument that measures heavy metal concentration from a colorimetric sensor array is presented. The use of eight sensing membranes, placed on a plastic support, allows to obtain the hue component of the HSV colour space of each one in order to determinate the concentration of metals present in a solution. The developed microcontroller-based system captures, in an ambient light environment, an image of the sensor array using an integrated micro-camera and shows the picture in a touch micro-LCD screen which acts as user interface. After image-processing of the regions of interest selected by the user, colour and concentration information are displayed on the screen.

  13. Handheld colorimeter for determination of heavy metal concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Ruiz, N; Martinez Olmos, A; Palma, A J [ECSens ETSIIT, Departamento de Electronica, Universidad de Granada. C/ Periodista Daniel Saucedo s/n 18071 Granada (Spain); Ariza, M; Capitan-Vallvey, L F [Department of Analytical Chemistry. Faculty of Sciences. University of Granada, E-18071 Granada (Spain); Vukovic, J, E-mail: nurilr@ugr.es [Department of Analytics and Control of Medicines, Faculty of Pharmacy and Biochemistry, University of Zagreb, A. Kovacica 1,HR-10000 Zagreb (Croatia)

    2011-08-17

    A portable instrument that measures heavy metal concentration from a colorimetric sensor array is presented. The use of eight sensing membranes, placed on a plastic support, allows to obtain the hue component of the HSV colour space of each one in order to determinate the concentration of metals present in a solution. The developed microcontroller-based system captures, in an ambient light environment, an image of the sensor array using an integrated micro-camera and shows the picture in a touch micro-LCD screen which acts as user interface. After image-processing of the regions of interest selected by the user, colour and concentration information are displayed on the screen.

  14. Portable Fourier Transform Spectroscopy for Analysis of Surface Contamination and Quality Control

    Science.gov (United States)

    Pugel, Diane

    2012-01-01

    Progress has been made into adapting and enhancing a commercially available infrared spectrometer for the development of a handheld device for in-field measurements of the chemical composition of various samples of materials. The intent is to duplicate the functionality of a benchtop Fourier transform infrared spectrometer (FTIR) within the compactness of a handheld instrument with significantly improved spectral responsivity. Existing commercial technology, like the deuterated L-alanine triglycine sulfide detectors (DLATGS), is capable of sensitive in-field chemical analysis. This proposed approach compares several subsystem elements of the FTIR inside of the commercial, non-benchtop system to the commercial benchtop systems. These subsystem elements are the detector, the preamplifier and associated electronics of the detector, the interferometer, associated readout parameters, and cooling. This effort will examine these different detector subsystem elements to look for limitations in each. These limitations will be explored collaboratively with the commercial provider, and will be prioritized to meet the deliverable objectives. The tool design will be that of a handheld gun containing the IR filament source and associated optics. It will operate in a point-and-shoot manner, pointing the source and optics at the sample under test and capturing the reflected response of the material in the same handheld gun. Data will be captured via the gun and ported to a laptop.

  15. How discriminating are discriminative instruments?

    Science.gov (United States)

    Hankins, Matthew

    2008-05-27

    The McMaster framework introduced by Kirshner & Guyatt is the dominant paradigm for the development of measures of health status and health-related quality of life (HRQL). The framework defines the functions of such instruments as evaluative, predictive or discriminative. Evaluative instruments are required to be sensitive to change (responsiveness), but there is no corresponding index of the degree to which discriminative instruments are sensitive to cross-sectional differences. This paper argues that indices of validity and reliability are not sufficient to demonstrate that a discriminative instrument performs its function of discriminating between individuals, and that the McMaster framework would be augmented by the addition of a separate index of discrimination. The coefficient proposed by Ferguson (Delta) is easily adapted to HRQL instruments and is a direct, non-parametric index of the degree to which an instrument distinguishes between individuals. While Delta should prove useful in the development and evaluation of discriminative instruments, further research is required to elucidate the relationship between the measurement properties of discrimination, reliability and responsiveness.

  16. How discriminating are discriminative instruments?

    Directory of Open Access Journals (Sweden)

    Hankins Matthew

    2008-05-01

    Full Text Available Abstract The McMaster framework introduced by Kirshner & Guyatt is the dominant paradigm for the development of measures of health status and health-related quality of life (HRQL. The framework defines the functions of such instruments as evaluative, predictive or discriminative. Evaluative instruments are required to be sensitive to change (responsiveness, but there is no corresponding index of the degree to which discriminative instruments are sensitive to cross-sectional differences. This paper argues that indices of validity and reliability are not sufficient to demonstrate that a discriminative instrument performs its function of discriminating between individuals, and that the McMaster framework would be augmented by the addition of a separate index of discrimination. The coefficient proposed by Ferguson (Delta is easily adapted to HRQL instruments and is a direct, non-parametric index of the degree to which an instrument distinguishes between individuals. While Delta should prove useful in the development and evaluation of discriminative instruments, further research is required to elucidate the relationship between the measurement properties of discrimination, reliability and responsiveness.

  17. Smart antennas for nuclear instruments

    International Nuclear Information System (INIS)

    Jain, Ranjan Bala; Singhi, B.M.

    2005-01-01

    The advances in the field of computer and communications are leading to the development of smart embedded nuclear instruments. These instruments have highly sophisticated signal-processing algorithms based on FPGA and ASICS, provisions of present day connectivity and user interfaces. The developments in the connectivity, standards and bus technologies have made possible to access these instruments on LAN and WAN with suitable reliability and security. To get rid of wires i.e. in order to access these instruments, without wires at any place, wireless technology has evolved and become integral part of day-to-day activities. The environment monitoring can be done remotely, if smart antennas are incorporated on these instruments

  18. Nuclear instrumentation for research reactors

    International Nuclear Information System (INIS)

    Hofer, Carlos G.; Pita, Antonio; Verrastro, Claudio A.; Maino, Eduardo J.

    1997-01-01

    The nuclear instrumentation for research reactors in Argentina was developed in 70'. A gradual modernization of all the nuclear instrumentation is planned. It includes start-up and power range instrumentation, as well as field monitors, clamp, scram and rod movement control logic. The new instrumentation is linked to a computer network, based on real time operating system for data acquisition, display and logging. This paper describes the modules and whole system aspects. (author). 2 refs

  19. Test-retest reliability of a handheld dynamometer for measurement of isometric cervical muscle strength.

    Science.gov (United States)

    Vannebo, Katrine Tranaas; Iversen, Vegard Moe; Fimland, Marius Steiro; Mork, Paul Jarle

    2018-03-02

    There is a lack of test-retest reliability studies of measurements of cervical muscle strength, taking into account gender and possible learning effects. To investigate test-retest reliability of measurement of maximal isometric cervical muscle strength by handheld dynamometry. Thirty women (age 20-58 years) and 28 men (age 20-60 years) participated in the study. Maximal isometric strength (neck flexion, neck extension, and right/left lateral flexion) was measured on three separate days at least five days apart by one evaluator. Intra-rater consistency tended to improve from day 1-2 measurements to day 2-3 measurements in both women and men. In women, the intra-class correlation coefficients (ICC) for day 2 to day 3 measurements were 0.91 (95% confidence interval [CI], 0.82-0.95) for neck flexion, 0.88 (95% CI, 0.76-0.94) for neck extension, 0.84 (95% CI, 0.68-0.92) for right lateral flexion, and 0.89 (95% CI, 0.78-0.95) for left lateral flexion. The corresponding ICCs among men were 0.86 (95% CI, 0.72-0.93) for neck flexion, 0.93 (95% CI, 0.85-0.97) for neck extension, 0.82 (95% CI, 0.65-0.91) for right lateral flexion and 0.73 (95% CI, 0.50-0.87) for left lateral flexion. This study describes a reliable and easy-to-administer test for assessing maximal isometric cervical muscle strength.

  20. Advancements in Actuated Musical Instruments

    DEFF Research Database (Denmark)

    Overholt, Daniel; Berdahl, Edgar; Hamilton, Robert

    2011-01-01

    are physical instruments that have been endowed with virtual qualities controlled by a computer in real-time but which are nevertheless tangible. These instruments provide intuitive and engaging new forms of interaction. They are different from traditional (acoustic) and fully automated (robotic) instruments...

  1. Software-Enabled Modular Instrumentation Systems

    NARCIS (Netherlands)

    Soijer, M.W.

    2003-01-01

    Like most other types of instrumentation systems, flight test instrumentation is not produced in series; its development is a one-time achievement by a test department. With the introduction of powerful digital computers, instrumentation systems have included data analysis tasks that were previously

  2. Nuclear instrument technician training

    International Nuclear Information System (INIS)

    Wollesen, E.S.

    1991-01-01

    This paper reports on Nuclear Instrument Technician (NIT) training that has developed at an accelerated rate over the past three decades. During the 1960's commercial nuclear power plants were in their infancy. For that reason, there is little wonder that NIT training had little structure and little creditability. NIT training, in many early plants, was little more than On-The Job Training (OJT). The seventies brought changes in Instrumentation and Controls as well as emphasis on the requirements for more in depth training and documentation. As in the seventies, the eighties saw not only changes in technologies but tighter requirements, standardized training and the development of accredited Nuclear Instrument Training; thus the conclusion: Nuclear Instrument Training Isn't What It Used To Be

  3. Single classifier, OvO, OvA and RCC multiclass classification method in handheld based smartphone gait identification

    Science.gov (United States)

    Raziff, Abdul Rafiez Abdul; Sulaiman, Md Nasir; Mustapha, Norwati; Perumal, Thinagaran

    2017-10-01

    Gait recognition is widely used in many applications. In the application of the gait identification especially in people, the number of classes (people) is many which may comprise to more than 20. Due to the large amount of classes, the usage of single classification mapping (direct classification) may not be suitable as most of the existing algorithms are mostly designed for the binary classification. Furthermore, having many classes in a dataset may result in the possibility of having a high degree of overlapped class boundary. This paper discusses the application of multiclass classifier mappings such as one-vs-all (OvA), one-vs-one (OvO) and random correction code (RCC) on handheld based smartphone gait signal for person identification. The results is then compared with a single J48 decision tree for benchmark. From the result, it can be said that using multiclass classification mapping method thus partially improved the overall accuracy especially on OvO and RCC with width factor more than 4. For OvA, the accuracy result is worse than a single J48 due to a high number of classes.

  4. Industrial instrumentation principles and design

    CERN Document Server

    Padmanabhan, Tattamangalam R

    2000-01-01

    Pneumatic, hydraulic and allied instrumentation schemes have given way to electronic schemes in recent years thanks to the rapid strides in electronics and allied areas. Principles, design and applications of such state-of-the-art instrumentation schemes form the subject matter of this book. Through representative examples, the basic building blocks of instrumentation schemes are identified and each of these building blocks discussed in terms of its design and interface characteristics. The common generic schemes synthesized with such building blocks are dealt with subsequently. This forms the scope of Part I. The focus in Part II is on application. Displacement and allied instrumentation, force and allied instrumentation and process instrumentation in terms of temperature, flow, pressure level and other common process variables are dealt with separately and exhaustively. Despite the diversity in the sensor principles and characteristics and the variety in the applications and their environments, it is possib...

  5. Instrumental analysis, second edition

    International Nuclear Information System (INIS)

    Christian, G.D.; O'Reilly, J.E.

    1988-01-01

    The second edition of Instrumental Analysis is a survey of the major instrument-based methods of chemical analysis. It appears to be aimed at undergraduates but would be equally useful in a graduate course. The volume explores all of the classical quantitative methods and contains sections on techniques that usually are not included in a semester course in instrumentation (such as electron spectroscopy and the kinetic methods). Adequate coverage of all of the methods contained in this book would require several semesters of focused study. The 25 chapters were written by different authors, yet the style throughout the book is more uniform than in the earlier edition. With the exception of a two-chapter course in analog and digital circuits, the book purports to de-emphasize instrumentation, focusing more on the theory behind the methods and the application of the methods to analytical problems. However, a detailed analysis of the instruments used in each method is by no means absent. The book has the favor of a user's guide to analysis

  6. Comparing surgical trays with redundant instruments with trays with reduced instruments: a cost analysis.

    Science.gov (United States)

    John-Baptiste, A; Sowerby, L J; Chin, C J; Martin, J; Rotenberg, B W

    2016-01-01

    When prearranged standard surgical trays contain instruments that are repeatedly unused, the redundancy can result in unnecessary health care costs. Our objective was to estimate potential savings by performing an economic evaluation comparing the cost of surgical trays with redundant instruments with surgical trays with reduced instruments ("reduced trays"). We performed a cost-analysis from the hospital perspective over a 1-year period. Using a mathematical model, we compared the direct costs of trays containing redundant instruments to reduced trays for 5 otolaryngology procedures. We incorporated data from several sources including local hospital data on surgical volume, the number of instruments on redundant and reduced trays, wages of personnel and time required to pack instruments. From the literature, we incorporated instrument depreciation costs and the time required to decontaminate an instrument. We performed 1-way sensitivity analyses on all variables, including surgical volume. Costs were estimated in 2013 Canadian dollars. The cost of redundant trays was $21 806 and the cost of reduced trays was $8803, for a 1-year cost saving of $13 003. In sensitivity analyses, cost savings ranged from $3262 to $21 395, based on the surgical volume at the institution. Variation in surgical volume resulted in a wider range of estimates, with a minimum of $3253 for low-volume to a maximum of $52 012 for high-volume institutions. Our study suggests moderate savings may be achieved by reducing surgical tray redundancy and, if applied to other surgical specialties, may result in savings to Canadian health care systems.

  7. Validation of Ankle Strength Measurements by Means of a Hand-Held Dynamometer in Adult Healthy Subjects

    Directory of Open Access Journals (Sweden)

    Andrea Ancillao

    2017-01-01

    Full Text Available Uniaxial Hand-Held Dynamometer (HHD is a low-cost device widely adopted in clinical practice to measure muscle force. HHD measurements depend on operator’s ability and joint movements. The aim of the work is to validate the use of a commercial HHD in both dorsiflexion and plantarflexion ankle strength measurements quantifying the effects of HHD misplacements and unwanted foot’s movements on the measurements. We used an optoelectronic system and a multicomponent load cell to quantify the sources of error in the manual assessment of the ankle strength due to both the operator’s ability to hold still the HHD and the transversal components of the exerted force that are usually neglected in clinical routine. Results showed that foot’s movements and angular misplacements of HHD on sagittal and horizontal planes were relevant sources of inaccuracy on the strength assessment. Moreover, ankle dorsiflexion and plantarflexion force measurements presented an inaccuracy less than 2% and higher than 10%, respectively. In conclusion, the manual use of a uniaxial HHD is not recommended for the assessment of ankle plantarflexion strength; on the contrary, it can be allowed asking the operator to pay strong attention to the HHD positioning in ankle dorsiflexion strength measurements.

  8. Handheld tympanometer measurements in conscious dogs for the evaluation of the middle ear and auditory tube.

    Science.gov (United States)

    Strain, George M; Fernandes, Asia J

    2015-06-01

    Otitis externa is frequently accompanied by otitis media, yet it can be difficult to evaluate the tympanum, middle ear and auditory tube without the use of advanced radiographic imaging. The objective was to develop techniques for tympanometry testing in conscious dogs and to present normative data for clinical use of this equipment to enable assessment of the tympanum, middle ear and auditory tube. Sixteen hounds (14 female) from a school teaching colony. Dogs were gently restrained in a standing position. After cleaning of the ear canal, a tympanometer probe tip extension was placed in the vertical canal and automated testing performed using a handheld device. Both ears were tested in all dogs. Acceptable recordings were obtained from both ears of 13 dogs, from one ear in each of two dogs and from neither ear of one dog, resulting in data from 28 of 32 (88%) ears. Otoscopic examination confirmed the absence of inflammation or any other obvious explanation for the noncompliant dogs. No significant differences were seen between ears for any measure. Normative data are reported for peak compliance, peak compliance pressure, gradient and ear canal volume. Tympanograms can be recorded in conscious dogs to assist in the evaluation of the middle ear structures. © 2015 ESVD and ACVD.

  9. User certification of hand-held x-ray tube based analytical fluorescent devices in a canadian context

    International Nuclear Information System (INIS)

    Maharaj, H.P.

    2005-01-01

    Safety education aims to reduce personal injury and improve well being. This health promotion principle is applied in the case of hand-held open beam x-ray tube based analytical x-ray devices. Such devices not only are light weight and portable, but also present high radiation exposure levels at the beam exit port and potentially can be used in a variety of industrial applications for determination of material composition. There is much potential for radiation risks to occur with resultant adverse effects if such devices are not used by trained individuals within controlled environments. A level of radiation safety knowledge and understanding of the device design, construction and performance characteristics appear warranted. To reduce radiation risks, user certification at a federal level was introduced in 2004 based on International Standards Organization 20807, since that standard comprises elements commensurate with risk reduction strategies. Within these contexts, a federally certified user is deemed to have acquired a level of safety knowledge and skills to facilitate safe use of the device. Certification, however, does not absolve the holder from obligations of compliance with applicable provincial, territorial or federal laws respecting device operation. The union of federal certification and applicable legislative mandated operational criteria reduces radiation risks overall. (author)

  10. The 2007 ESO Instrument Calibration Workshop

    CERN Document Server

    Kaufer, Andreas; ESO Workshop

    2008-01-01

    The 2007 ESO Instrument Calibration workshop brought together more than 120 participants with the objective to a) foster the sharing of information, experience and techniques between observers, instrument developers and instrument operation teams, b) review the actual precision and limitations of the applied instrument calibration plans, and c) collect the current and future requirements by the ESO users. These present proceedings include the majority of the workshop’s contributions and document the status quo of instrument calibration at ESO in large detail. Topics covered are: Optical Spectro-Imagers, Optical Multi-Object Spectrographs, NIR and MIR Spectro-Imagers, High-Resolution Spectrographs, Integral Field Spectrographs, Adaptive Optics Instruments, Polarimetric Instruments, Wide Field Imagers, Interferometric Instruments as well as other crucial aspects such as data flow, quality control, data reduction software and atmospheric effects. It was stated in the workshop that "calibration is a life-long l...

  11. The Choice of Innovation Policy Instruments

    DEFF Research Database (Denmark)

    Borrás, Susana; Edquist, Charles

    The purpose of this article is to discuss the different types of instruments of innovation policy, to examine how governments and public agencies in different countries and different times have used these instruments differently, to explore the political nature of instrument choice and design (and...... associated issues), and to elaborate a set of criteria for the selection and design of the instruments in relation to the formulation of innovation policy. The article argues that innovation policy instruments must be designed and combined into mixes in ways that address the problems of the innovation system....... These mixes are often called “policy mix”. The problem-oriented nature of the design of instrument mixes is what makes innovation policy instruments ‘systemic’....

  12. The Choice of Innovation Policy Instruments

    DEFF Research Database (Denmark)

    Borrás, Susana; Edquist, Charles

    2013-01-01

    The purpose of this article is to discuss the different types of instruments of innovation policy, to examine how governments and public agencies in different countries and different times have used these instruments differently, to explore the political nature of instrument choice and design (and...... associated issues), and to elaborate a set of criteria for the selection and design of the instruments in relation to the formulation of innovation policy. The article argues that innovation policy instruments must be designed and combined into mixes in ways that address the problems of the innovation system....... These mixes are often called “policy mix”. The problem-oriented nature of the design of instrument mixes is what makes innovation policy instruments ‘systemic’....

  13. The IKARUS instrument

    International Nuclear Information System (INIS)

    Gerster, H.J.; Stein, G.

    1994-01-01

    When the Federal Government decided on a 25% reduction of CO 2 emissions till 2005 in 1990 the necessity resulted that an instrument has to be developed for the analysis and assessment of the ecological, economic and energetic impact of different reduction strategies. The development task was awarded by the BMFT to the Research Centre Juelich in cooperation with well-known institutions of energy system research. The total instrument is scheduled to be finished by the end of 1994. For the decentral use of the instrument by a wide specialist public the developed models and data banks which are equipped with a user-friendly surface are suited for larger PCs (486, 16 MB RAM/500-1000 MB ROM). (orig.) [de

  14. Verification of the Indicating Measuring Instruments Taking into Account their Instrumental Measurement Uncertainty

    Directory of Open Access Journals (Sweden)

    Zakharov Igor

    2017-12-01

    Full Text Available The specific features of the measuring instruments verification based on the results of their calibration are considered. It is noted that, in contrast to the verification procedure used in the legal metrology, the verification procedure for calibrated measuring instruments has to take into account the uncertainty of measurements into account. In this regard, a large number of measuring instruments, considered as those that are in compliance after verification in the legal metrology, turns out to be not in compliance after calibration. In this case, it is necessary to evaluate the probability of compliance of indicating measuring instruments. The procedure of compliance probability determination on the basis of the Monte Carlo method is considered. An example of calibration of a Vernier caliper is given.

  15. Instrumentation Cables Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Muna, Alice Baca [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); LaFleur, Chris Bensdotter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-10-01

    A fire at a nuclear power plant (NPP) has the potential to damage structures, systems, and components important to safety, if not promptly detected and suppressed. At Browns Ferry Nuclear Power Plant on March 22, 1975, a fire in the reactor building damaged electrical power and control systems. Damage to instrumentation cables impeded the function of both normal and standby reactor coolant systems, and degraded the operators’ plant monitoring capability. This event resulted in additional NRC involvement with utilities to ensure that NPPs are properly protected from fire as intended by the NRC principle design criteria (i.e., general design criteria 3, Fire Protection). Current guidance and methods for both deterministic and performance based approaches typically make conservative (bounding) assumptions regarding the fire-induced failure modes of instrumentation cables and those failure modes effects on component and system response. Numerous fire testing programs have been conducted in the past to evaluate the failure modes and effects of electrical cables exposed to severe thermal conditions. However, that testing has primarily focused on control circuits with only a limited number of tests performed on instrumentation circuits. In 2001, the Nuclear Energy Institute (NEI) and the Electric Power Research Institute (EPRI) conducted a series of cable fire tests designed to address specific aspects of the cable failure and circuit fault issues of concern1. The NRC was invited to observe and participate in that program. The NRC sponsored Sandia National Laboratories to support this participation, whom among other things, added a 4-20 mA instrumentation circuit and instrumentation cabling to six of the tests. Although limited, one insight drawn from those instrumentation circuits tests was that the failure characteristics appeared to depend on the cable insulation material. The results showed that for thermoset insulated cables, the instrument reading tended to drift

  16. Minimally invasive instrumentation without fusion during posterior thoracic corpectomies: a comparison of percutaneously instrumented nonfused segments with open instrumented fused segments.

    Science.gov (United States)

    Lau, Darryl; Chou, Dean

    2017-07-01

    OBJECTIVE During the mini-open posterior corpectomy, percutaneous instrumentation without fusion is performed above and below the corpectomy level. In this study, the authors' goal was to compare the perioperative and long-term implant failure rates of patients who underwent nonfused percutaneous instrumentation with those of patients who underwent traditional open instrumented fusion. METHODS Adult patients who underwent posterior thoracic corpectomies with cage reconstruction between 2009 and 2014 were identified. Patients who underwent mini-open corpectomy had percutaneous instrumentation without fusion, and patients who underwent open corpectomy had instrumented fusion above and below the corpectomy site. The authors compared perioperative outcomes and rates of implant failure requiring reoperation between the open (fused) and mini-open (unfused) groups. RESULTS A total of 75 patients were identified, and 53 patients (32 open and 21 mini-open) were available for followup. The mean patient age was 52.8 years, and 56.6% of patients were male. There were no significant differences in baseline variables between the 2 groups. The overall perioperative complication rate was 15.1%, and there was no significant difference between the open and mini-open groups (18.8% vs 9.5%; p = 0.359). The mean hospital stay was 10.5 days. The open group required a significantly longer stay than the mini-open group (12.8 vs 7.1 days; p open and mini-open groups at 6 months (3.1% vs 0.0%, p = 0.413), 1 year (10.7% vs 6.2%, p = 0.620), and 2 years (18.2% vs 8.3%, p = 0.438). The overall mean follow-up was 29.2 months. CONCLUSIONS These findings suggest that percutaneous instrumentation without fusion in mini-open transpedicular corpectomies offers similar implant failure and reoperation rates as open instrumented fusion as far out as 2 years of follow-up.

  17. Environment for the instruments

    International Nuclear Information System (INIS)

    Ambro, P.

    1992-01-01

    A properly conditioned AC power supply is necessary for reliable functioning of instruments. Electric mains power is produced primarily for industry, workshops, lighting and household uses. Its quality is adjusted to these uses. In areas sand countries with a fast growing demand for electric power, these requirements are far from being met. Electronic instruments and computers, especially in these countries, need protection against disturbances of the mains supply. A clean and dry environment is needed for reliable functioning and long life of instruments. High humidity, specially at higher temperatures, changes the characteristics of electronic components. Moreover, under these conditions fungal growth causes leakage of currents and corrosion causes poor contacts. The presence of dust enhances these effects. They give rise to malfunction of instruments, particularly of high voltage equipment

  18. Environment for the instruments

    Energy Technology Data Exchange (ETDEWEB)

    Ambro, P

    1993-12-31

    A properly conditioned AC power supply is necessary for reliable functioning of instruments. Electric mains power is produced primarily for industry, workshops, lighting and household uses. Its quality is adjusted to these uses. In areas sand countries with a fast growing demand for electric power, these requirements are far from being met. Electronic instruments and computers, especially in these countries, need protection against disturbances of the mains supply. A clean and dry environment is needed for reliable functioning and long life of instruments. High humidity, specially at higher temperatures, changes the characteristics of electronic components. Moreover, under these conditions fungal growth causes leakage of currents and corrosion causes poor contacts. The presence of dust enhances these effects. They give rise to malfunction of instruments, particularly of high voltage equipment

  19. Evaluating the Relational Coordination instrument

    DEFF Research Database (Denmark)

    Edwards, Kasper; Lundstrøm, Sanne Lykke

    2014-01-01

    consistency, interrater agreement and reliability, structural validity, content validity. However as relational coordination is being used as a diagnostics tool it is important to examine further if the instrument can measure changes. Indeed we need to know how precise and sensitive the instrument is when....... We distinguish between statistical and clinical significance. Statistical significance is calculated using T-test. Clinical significance is the minimal amount of change in relational coordination score that is not considered noise. Sensitivity of the instrument i.e. the ability of the instrument...

  20. Developing a workplace resilience instrument.

    Science.gov (United States)

    Mallak, Larry A; Yildiz, Mustafa

    2016-05-27

    Resilience benefits from the use of protective factors, as opposed to risk factors, which are associated with vulnerability. Considerable research and instrument development has been conducted in clinical settings for patients. The need existed for an instrument to be developed in a workplace setting to measure resilience of employees. This study developed and tested a resilience instrument for employees in the workplace. The research instrument was distributed to executives and nurses working in the United States in hospital settings. Five-hundred-forty completed and usable responses were obtained. The instrument contained an inventory of workplace resilience, a job stress questionnaire, and relevant demographics. The resilience items were written based on previous work by the lead author and inspired by Weick's [1] sense-making theory. A four-factor model yielded an instrument having psychometric properties showing good model fit. Twenty items were retained for the resulting Workplace Resilience Instrument (WRI). Parallel analysis was conducted with successive iterations of exploratory and confirmatory factor analyses. Respondents were classified based on their employment with either a rural or an urban hospital. Executives had significantly higher WRI scores than nurses, controlling for gender. WRI scores were positively and significantly correlated with years of experience and the Brief Job Stress Questionnaire. An instrument to measure individual resilience in the workplace (WRI) was developed. The WRI's four factors identify dimensions of workplace resilience for use in subsequent investigations: Active Problem-Solving, Team Efficacy, Confident Sense-Making, and Bricolage.