WorldWideScience

Sample records for handheld computerized device

  1. Digital forensics for handheld devices

    CERN Document Server

    Doherty, Eamon P

    2012-01-01

    Approximately 80 percent of the world's population now owns a cell phone, which can hold evidence or contain logs about communications concerning a crime. Cameras, PDAs, and GPS devices can also contain information related to corporate policy infractions and crimes. Aimed to prepare investigators in the public and private sectors, Digital Forensics for Handheld Devices examines both the theoretical and practical aspects of investigating handheld digital devices. This book touches on all areas of mobile device forensics, including topics from the legal, technical, academic, and social aspects o

  2. Video Browsing on Handheld Devices

    Science.gov (United States)

    Hürst, Wolfgang

    Recent improvements in processing power, storage space, and video codec development enable users now to playback video on their handheld devices in a reasonable quality. However, given the form factor restrictions of such a mobile device, screen size still remains a natural limit and - as the term "handheld" implies - always will be a critical resource. This is not only true for video but any data that is processed on such devices. For this reason, developers have come up with new and innovative ways to deal with large documents in such limited scenarios. For example, if you look at the iPhone, innovative techniques such as flicking have been introduced to skim large lists of text (e.g. hundreds of entries in your music collection). Automatically adapting the zoom level to, for example, the width of table cells when double tapping on the screen enables reasonable browsing of web pages that have originally been designed for large, desktop PC sized screens. A multi touch interface allows you to easily zoom in and out of large text documents and images using two fingers. In the next section, we will illustrate that advanced techniques to browse large video files have been developed in the past years, as well. However, if you look at state-of-the-art video players on mobile devices, normally just simple, VCR like controls are supported (at least at the time of this writing) that only allow users to just start, stop, and pause video playback. If supported at all, browsing and navigation functionality is often restricted to simple skipping of chapters via two single buttons for backward and forward navigation and a small and thus not very sensitive timeline slider.

  3. Characterizing the reflectivity of handheld display devices.

    Science.gov (United States)

    Liu, Peter; Badano, Aldo

    2014-08-01

    With increased use of handheld and tablet display devices for viewing medical images, methods for consistently measuring reflectivity of the devices are needed. In this note, the authors report on the characterization of diffuse reflections for handheld display devices including mobile phones and tablets using methods recommended by the American Association of Physicists in Medicine Task Group 18 (TG18). The authors modified the diffuse reflectance coefficient measurement method outlined in the TG18 report. The authors measured seven handheld display devices (two phones and five tablets) and three workstation displays. The device was attached to a black panel with Velcro. To study the effect of the back surface on the diffuse reflectance coefficient, the authors created Styrofoam masks with different size square openings and placed it in front of the device. Overall, for each display device, measurements of illuminance and reflected luminance on the display screen were taken. The authors measured with no mask, with masks of varying size, and with display-size masks, and calculated the corresponding diffuse reflectance coefficient. For all handhelds, the diffuse reflectance coefficient measured with no back panel were lower than measurements performed with a mask. The authors found an overall increase in reflectivity as the size of the mask decreases. For workstations displays, diffuse reflectance coefficients were higher when no back panel was used, and higher than with masks. In all cases, as luminance increased, illuminance increased, but not at the same rate. Since the size of handheld displays is smaller than that of workstation devices, the TG18 method suffers from a dependency on illumination condition. The authors show that the diffuse reflection coefficients can vary depending on the nature of the back surface of the illuminating box. The variability in the diffuse coefficient can be as large as 20% depending on the size of the mask. For all measurements

  4. Optical links in handheld multimedia devices

    Science.gov (United States)

    van Geffen, S.; Duis, J.; Miller, R.

    2008-04-01

    Ever emerging applications in handheld multimedia devices such as mobile phones, laptop computers, portable video games and digital cameras requiring increased screen resolutions are driving higher aggregate bitrates between host processor and display(s) enabling services such as mobile video conferencing, video on demand and TV broadcasting. Larger displays and smaller phones require complex mechanical 3D hinge configurations striving to combine maximum functionality with compact building volumes. Conventional galvanic interconnections such as Micro-Coax and FPC carrying parallel digital data between host processor and display module may produce Electromagnetic Interference (EMI) and bandwidth limitations caused by small cable size and tight cable bends. To reduce the number of signals through a hinge, the mobile phone industry, organized in the MIPI (Mobile Industry Processor Interface) alliance, is currently defining an electrical interface transmitting serialized digital data at speeds >1Gbps. This interface allows for electrical or optical interconnects. Above 1Gbps optical links may offer a cost effective alternative because of their flexibility, increased bandwidth and immunity to EMI. This paper describes the development of optical links for handheld communication devices. A cable assembly based on a special Plastic Optical Fiber (POF) selected for its mechanical durability is terminated with a small form factor molded lens assembly which interfaces between an 850nm VCSEL transmitter and a receiving device on the printed circuit board of the display module. A statistical approach based on a Lean Design For Six Sigma (LDFSS) roadmap for new product development tries to find an optimum link definition which will be robust and low cost meeting the power consumption requirements appropriate for battery operated systems.

  5. A Cognitive Style Perspective to Handheld Devices: Customization vs. Personalization

    Science.gov (United States)

    Hsieh, Chen-Wei; Chen, Sherry Y.

    2016-01-01

    Handheld devices are widely applied to support open and distributed learning, where students are diverse. On the other hand, customization and personalization can be applied to accommodate students' diversities. However, paucity of research compares the effects of customization and personalization in the context of handheld devices. To this end, a…

  6. Extensional rheometry with a handheld mobile device

    Science.gov (United States)

    Marshall, Kristin A.; Liedtke, Aleesha M.; Todt, Anika H.; Walker, Travis W.

    2017-06-01

    The on-site characterization of complex fluids is important for a number of academic and industrial applications. Consequently, a need exists to develop portable rheometers that can provide in the field diagnostics and serve as tools for rapid quality assurance. With the advancement of smartphone technology and the widespread global ownership of smart devices, mobile applications are attractive as platforms for rheological characterization. The present work investigates the use of a smartphone device for the extensional characterization of a series of Boger fluids composed of glycerol/water and poly(ethylene oxide), taking advantage of the increasing high-speed video capabilities (currently up to 240 Hz capture rate at 720p) of smartphone cameras. We report a noticeable difference in the characterization of samples with slight variations in polymer concentration and discuss current device limitations. Potential benefits of a handheld extensional rheometer include its use as a point-of-care diagnostic tool, especially in developing communities, as well as a simple and inexpensive tool for assessing product quality in industry.

  7. Image Quality Characteristics of Handheld Display Devices for Medical Imaging

    Science.gov (United States)

    Yamazaki, Asumi; Liu, Peter; Cheng, Wei-Chung; Badano, Aldo

    2013-01-01

    Handheld devices such as mobile phones and tablet computers have become widespread with thousands of available software applications. Recently, handhelds are being proposed as part of medical imaging solutions, especially in emergency medicine, where immediate consultation is required. However, handheld devices differ significantly from medical workstation displays in terms of display characteristics. Moreover, the characteristics vary significantly among device types. We investigate the image quality characteristics of various handheld devices with respect to luminance response, spatial resolution, spatial noise, and reflectance. We show that the luminance characteristics of the handheld displays are different from those of workstation displays complying with grayscale standard target response suggesting that luminance calibration might be needed. Our results also demonstrate that the spatial characteristics of handhelds can surpass those of medical workstation displays particularly for recent generation devices. While a 5 mega-pixel monochrome workstation display has horizontal and vertical modulation transfer factors of 0.52 and 0.47 at the Nyquist frequency, the handheld displays released after 2011 can have values higher than 0.63 at the respective Nyquist frequencies. The noise power spectra for workstation displays are higher than 1.2×10−5 mm2 at 1 mm−1, while handheld displays have values lower than 3.7×10−6 mm2. Reflectance measurements on some of the handheld displays are consistent with measurements for workstation displays with, in some cases, low specular and diffuse reflectance coefficients. The variability of the characterization results among devices due to the different technological features indicates that image quality varies greatly among handheld display devices. PMID:24236113

  8. Evaluation of an enclosed ultraviolet-C radiation device for decontamination of mobile handheld devices.

    Science.gov (United States)

    Mathew, J Itty; Cadnum, Jennifer L; Sankar, Thriveen; Jencson, Annette L; Kundrapu, Sirisha; Donskey, Curtis J

    2016-06-01

    Mobile handheld devices used in health care settings may become contaminated with health care-associated pathogens. We demonstrated that an enclosed ultraviolet-C radiation device was effective in rapidly reducing methicillin-resistant Staphylococcus aureus, and with longer exposure times, Clostridium difficile spores, on glass slides and reducing contamination on in-use mobile handheld devices. Published by Elsevier Inc.

  9. Web-Based Spatial Training Using Handheld Touch Screen Devices

    Science.gov (United States)

    Martin-Dorta, Norena; Saorin, Jose Luis; Contero, Manuel

    2011-01-01

    This paper attempts to harness the opportunities for mobility and the new user interfaces that handheld touch screen devices offer, in a non-formal learning context, with a view to developing spatial ability. This research has addressed two objectives: first, analyzing the effects that training can have on spatial visualisation using the…

  10. Diagnostic efficacy of handheld devices for emergency radiologic consultation.

    LENUS (Irish Health Repository)

    Toomey, Rachel J

    2010-02-01

    Orthopedic injury and intracranial hemorrhage are commonly encountered in emergency radiology, and accurate and timely diagnosis is important. The purpose of this study was to determine whether the diagnostic accuracy of handheld computing devices is comparable to that of monitors that might be used in emergency teleconsultation.

  11. Epilepsy Forewarning Using A Hand-Held Device

    Energy Technology Data Exchange (ETDEWEB)

    Hively, LM

    2005-02-21

    Over the last decade, ORNL has developed and patented a novel approach for forewarning of a large variety of machine and biomedical events. The present implementation uses desktop computers to analyze archival data. This report describes the next logical step in this effort, namely use of a hand-held device for the analysis.

  12. Human Handheld-Device Interaction : An Adaptive User Interface

    NARCIS (Netherlands)

    Fitrianie, S.

    2010-01-01

    The move to smaller, lighter and more powerful (mobile) handheld devices, whe-ther PDAs or smart-phones, looks like a trend that is building up speed. With numerous embedded technologies and wireless connectivity, the drift opens up unlimited opportunities in daily activities that are both more

  13. An Adaptive Geometry Game for Handheld Devices

    Directory of Open Access Journals (Sweden)

    Harri Ketamo

    2003-01-01

    Full Text Available The development of adaptive learning systems is only in the very beginning. In fact, the concept of adaptive learning systems range from different user interfaces to behaviour adaptive systems as well as from the place and time independent systems to terminal independent systems. When approaching the concept of adaptive learning materials, we must first have conceptual models of the behaviour of different learners within digital environments.The aim of this study was to develop a geometry learning game that adapts to user’s behaviour. The learners in this study were six years old Finnish pre-school pupils. The adaptive system was very limited and the observed behaviour was defined as very simple. However, the software developed achieves good learning results among the tested pupils. The study shows that the learning effect is very promising with this kind of handheld platform and simple adaptation system. This study gives good visions of what can be achieved with more complex behaviour adaptive systems in the field of eLearning.

  14. Interactive topology optimization on hand-held devices

    DEFF Research Database (Denmark)

    Aage, Niels; Nobel-Jørgensen, Morten; Andreasen, Casper Schousboe

    2013-01-01

    This paper presents an interactive topology optimization application designed for hand-held devices running iOS or Android. The TopOpt app solves the 2D minimum compliance problem with interactive control of load and support positions as well as volume fraction. Thus, it is possible to change......OS devices from the Apple App Store, at Google Play for the Android platform, and a web-version can be run from www.topopt.dtu.dk....

  15. Handheld Diagnostic Device Delivers Quick Medical Readings

    Science.gov (United States)

    2014-01-01

    To monitor astronauts' health remotely, Glenn Research Center awarded SBIR funding to Cambridge, Massachusetts-based DNA Medical Institute, which developed a device capable of analyzing blood cell counts and a variety of medical biomarkers. The technology will prove especially useful in rural areas without easy access to labs.

  16. Absorption Related to Hand-Held Devices in Data Mode

    DEFF Research Database (Denmark)

    Andersen, Jørgen Bach; Nielsen, Jesper Ødum; Pedersen, Gert F.

    2016-01-01

    The human body has an influence on the radiation from handheld devices like smartphones, tablets and laptops, part of the energy is absorbed and the spatial distribution of the radiated part is modified. Previous studies of whole body absorp- tion have mainly been numerical or related to talk mode....... In the present paper an experimental study involving four volunteers and three different devices is performed from 0.5 to 3 GHz. The devices are a laptop, a tablet, and a smartphone all held in the lap. The 3D distribution of radiation is measured. Comparing the integrated power in the case of a person present...

  17. A hand-held robotic device for peripheral intravenous catheterization.

    Science.gov (United States)

    Cheng, Zhuoqi; Davies, Brian L; Caldwell, Darwin G; Barresi, Giacinto; Xu, Qinqi; Mattos, Leonardo S

    2017-12-01

    Intravenous catheterization is frequently required for numerous medical treatments. However, this process is characterized by a high failure rate, especially when performed on difficult patients such as newborns and infants. Very young patients have small veins, and that increases the chances of accidentally puncturing the catheterization needle directly through them. In this article, we present the design, development and experimental evaluation of a novel hand-held robotic device for improving the process of peripheral intravenous catheterization by facilitating the needle insertion procedure. To our knowledge, this design is the first hand-held robotic device for assisting in the catheterization insertion task. Compared to the other available technologies, it has several unique advantages such as being compact, low-cost and able to reliably detect venipuncture. The system is equipped with an electrical impedance sensor at the tip of the catheterization needle, which provides real-time measurements used to supervise and control the catheter insertion process. This allows the robotic system to precisely position the needle within the lumen of the target vein, leading to enhanced catheterization success rate. Experiments conducted to evaluate the device demonstrated that it is also effective to deskill the task. Naïve subjects achieved an average catheterization success rate of 88% on a 1.5 mm phantom vessel with the robotic device versus 12% with the traditional unassisted system. The results of this work prove the feasibility of a hand-held assistive robotic device for intravenous catheterization and show that such device has the potential to greatly improve the success rate of these difficult operations.

  18. Fast, cheap and in control: spectral imaging with handheld devices

    Science.gov (United States)

    Gooding, Edward A.; Deutsch, Erik R.; Huehnerhoff, Joseph; Hajian, Arsen R.

    2017-05-01

    Remote sensing has moved out of the laboratory and into the real world. Instruments using reflection or Raman imaging modalities become faster, cheaper and more powerful annually. Enabling technologies include virtual slit spectrometer design, high power multimode diode lasers, fast open-loop scanning systems, low-noise IR-sensitive array detectors and low-cost computers with touchscreen interfaces. High-volume manufacturing assembles these components into inexpensive portable or handheld devices that make possible sophisticated decision-making based on robust data analytics. Examples include threat, hazmat and narcotics detection; remote gas sensing; biophotonic screening; environmental remediation and a host of other applications.

  19. 75 FR 10502 - In the Matter of Certain Electronic Devices, Including Handheld Wireless Communications Devices...

    Science.gov (United States)

    2010-03-08

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-667; Investigation No. 337-TA-673] In the Matter of Certain Electronic Devices, Including Handheld Wireless Communications Devices; Notice of... Entirety AGENCY: U.S. International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that...

  20. A handheld optical device for skin profile measurement

    Science.gov (United States)

    Sun, Jiuai; Liu, Xiaojin

    2018-04-01

    This paper describes a portable optical scanning device designed for skin surface measurement on both colour and 3D geometry through a relative easy and cost effective multiple light source photometric stereo method. The validation of colour recovered had been verified through its application on skin lesion segmentation in our early work. This paper focuses on the reconstructed topographic data which are subject to further evaluation and advancement. The evaluation work takes the skin in vitro as an application scenario and compares the experimental result to that obtained by using a commercial product. The experiments show that this handheld device can measure the skin profile significantly closer to that of the ground truth and have the additional function of skin colour recovery.

  1. Using handheld devices for real-time wireless teleconsultation.

    Science.gov (United States)

    Banitsas, K A; Georgiadis, P; Tachakra, S; Cavouras, D

    2004-01-01

    Recent advances in the hardware of handheld devices, opened up the way for newer applications in the healthcare sector, and more specifically, in the teleconsultation field. Out of these devices, this paper focuses on the services that personal digital assistants and smartphones can provide to improve the speed, quality and ease of delivering a medical opinion from a distance and laying the ground for an all-wireless hospital. In that manner, PDAs were used to wirelessly support the viewing of digital imaging and communication in medicine (DICOM) images and to allow for mobile videoconferencing while within the hospital. Smartphones were also used to carry still images, multiframes and live video outside the hospital. Both of these applications aimed at increasing the mobility of the consultant while improving the healthcare service.

  2. Robust sleep quality quantification method for a personal handheld device.

    Science.gov (United States)

    Shin, Hangsik; Choi, Byunghun; Kim, Doyoon; Cho, Jaegeol

    2014-06-01

    The purpose of this study was to develop and validate a novel method for sleep quality quantification using personal handheld devices. The proposed method used 3- or 6-axes signals, including acceleration and angular velocity, obtained from built-in sensors in a smartphone and applied a real-time wavelet denoising technique to minimize the nonstationary noise. Sleep or wake status was decided on each axis, and the totals were finally summed to calculate sleep efficiency (SE), regarded as sleep quality in general. The sleep experiment was carried out for performance evaluation of the proposed method, and 14 subjects participated. An experimental protocol was designed for comparative analysis. The activity during sleep was recorded not only by the proposed method but also by well-known commercial applications simultaneously; moreover, activity was recorded on different mattresses and locations to verify the reliability in practical use. Every calculated SE was compared with the SE of a clinically certified medical device, the Philips (Amsterdam, The Netherlands) Actiwatch. In these experiments, the proposed method proved its reliability in quantifying sleep quality. Compared with the Actiwatch, accuracy and average bias error of SE calculated by the proposed method were 96.50% and -1.91%, respectively. The proposed method was vastly superior to other comparative applications with at least 11.41% in average accuracy and at least 6.10% in average bias; average accuracy and average absolute bias error of comparative applications were 76.33% and 17.52%, respectively.

  3. An Investigation of Game-Embedded Handheld Devices to Enhance English Learning

    Science.gov (United States)

    Hung, Hui-Chun; Young, Shelley Shwu-Ching

    2015-01-01

    This study proposed and implemented a system combining the advantages of both educational games and wireless handheld technology to promote the interactive English learning in the classroom setting. An interactive English vocabulary acquisition board game was designed with the system being implemented on handheld devices. Thirty sixth-grade…

  4. 78 FR 27441 - NIJ Evaluation of Hand-Held Cell Phone Detector Devices

    Science.gov (United States)

    2013-05-10

    ...The National Institute of Justice (NIJ) is soliciting interest in supplying hand-held cell phone detector devices for participation in an evaluation by the NIJ Corrections Technology Center of Excellence (CXCoE).

  5. Improving car passengers' comfort and experience by supporting the use of handheld devices.

    Science.gov (United States)

    van Veen, S A T; Hiemstra-van Mastrigt, S; Kamp, I; Vink, P

    2014-01-01

    There is a demand for interiors to support other activities in a car than controlling the vehicle. Currently, this is the case for the car passengers and--in the future--autonomous driving cars will also facilitate drivers to perform other activities. One of these activities is working with handheld devices. Previous research shows that people experience problems when using handheld devices in a moving vehicle and the use of handheld devices generally causes unwanted neck flexion [Young et al. 2012; Sin and Zu 2011; Gold et al.2011]. In this study, armrests are designed to support the arms when using handheld devices in a driving car in order to decrease neck flexion. Neck flexion was measured by attaching markers on the C7 and tragus. Discomfort was indicated on a body map on a scale 1-10. User experience was evaluated in a semi-structured interview. Neck flexion is significantly decreased by the support of the armrests and approaches a neutral position. Furthermore, overall comfort and comfort in the neck region specifically are significantly increased. Subjects appreciate the body posture facilitated by the armrests and 9 out of 10 prefer using handheld devices with the armrests compared to using handheld devices without the armrests. More efforts are needed to develop the mock-up into an established product, but the angles and dimensions presented in this study could serve as guidelines.

  6. Performance Analysis of Nomadic Mobile Services on Multi-homed Handheld Devices

    NARCIS (Netherlands)

    Pawar, P.; van Beijnum, Bernhard J.F.; van Sinderen, Marten J.; Aggarwal, Akshai; De Clercq, Frederic

    2007-01-01

    Compared to their predecessors, the current generation handheld mobile devices possess higher processing power, increased memory and new multi-homing capabilities. These features combined with the widespread acceptance and use of these devices result in a situation where mobile devices are no longer

  7. Ultrasonography with a hand-held device for the diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Kameda, Toru; Takahashi, Isao

    2009-01-01

    The purpose of this study was to evaluate the accuracy of ultrasonography (US) with a hand-held device for the diagnosis of acute appendicitis in the emergency room. US with a hand-held device was performed by the first author in 33 patients suspected of having appendicitis in the emergency room. From these 33 patients, 24 who subsequently underwent computed tomography (CT) or surgery were included in this study. The accuracy of US with the hand-held device for the diagnosis of acute appendicitis was evaluated based on the findings of CT or surgery. CT and surgery were performed in 22 and 12 patients, respectively. Final diagnoses were acute appendicitis (n=18), terminal ileitis (n=2), pelvic inflammatory disease (n=2), diverticulitis (n=1), and ureterolithiasis (n=1). The US yielded a sensitivity of 78% and a positive predictive value of 100%. The shortest distance between the abdominal wall and the appendix measured on CT was less than 40 mm in 11 patients. In ten (91%) of the 11 patients US with the hand-held device showed the swollen appendix. US with a hand-held device is potentially useful in the positive identification of acute appendicitis, but further investigation is needed to prove its utility in the routine diagnosis of acute appendicitis. (author)

  8. Detection of fecal contamination on beef meat surfaces using handheld fluorescence imaging device (HFID)

    Science.gov (United States)

    Current meat inspection in slaughter plants, for food safety and quality attributes including potential fecal contamination, is conducted through by visual examination human inspectors. A handheld fluorescence-based imaging device (HFID) was developed to be an assistive tool for human inspectors by ...

  9. Learning Motivation and Adaptive Video Caption Filtering for EFL Learners Using Handheld Devices

    Science.gov (United States)

    Hsu, Ching-Kun

    2015-01-01

    The aim of this study was to provide adaptive assistance to improve the listening comprehension of eleventh grade students. This study developed a video-based language learning system for handheld devices, using three levels of caption filtering adapted to student needs. Elementary level captioning excluded 220 English sight words (see Section 1…

  10. Swarm Optimization-Based Magnetometer Calibration for Personal Handheld Devices

    Directory of Open Access Journals (Sweden)

    Naser El-Sheimy

    2012-09-01

    Full Text Available Inertial Navigation Systems (INS consist of accelerometers, gyroscopes and a processor that generates position and orientation solutions by integrating the specific forces and rotation rates. In addition to the accelerometers and gyroscopes, magnetometers can be used to derive the user heading based on Earth’s magnetic field. Unfortunately, the measurements of the magnetic field obtained with low cost sensors are usually corrupted by several errors, including manufacturing defects and external electro-magnetic fields. Consequently, proper calibration of the magnetometer is required to achieve high accuracy heading measurements. In this paper, a Particle Swarm Optimization (PSO-based calibration algorithm is presented to estimate the values of the bias and scale factor of low cost magnetometers. The main advantage of this technique is the use of the artificial intelligence which does not need any error modeling or awareness of the nonlinearity. Furthermore, the proposed algorithm can help in the development of Pedestrian Navigation Devices (PNDs when combined with inertial sensors and GPS/Wi-Fi for indoor navigation and Location Based Services (LBS applications.

  11. A conceptual application for computer-based procedures for handheld devices

    International Nuclear Information System (INIS)

    Sofie, Lunde-Hanssen Linda

    2014-01-01

    This paper describes the concepts and proposed design principles for an application for computer-based procedures (CBPs) for field operators in the nuclear domain (so-called handheld procedures). The concept is focused on the field operators' work with procedures and the communication and coordination between field operators and control room operators. The goal is to overcome challenges with shared situation awareness (SA) in a distributed team by providing effective and usable information design. An iterative design method and user-centred design is used for tailoring the concept to the context of field operations. The resulting concept supports the execution of procedures where close collaboration is needed between control room and field operations, e.g. where particular procedure steps are executed from remote control points and others from the control room. The resulting conceptual application for CBPs on handheld devices is developed for mitigating the SA challenges and designing for usability and ease of use

  12. A conceptual application for computer-based procedures for handheld devices

    Energy Technology Data Exchange (ETDEWEB)

    Sofie, Lunde-Hanssen Linda [Industrial Psychology, Institute for Energy Technology, Halden (Norway)

    2014-08-15

    This paper describes the concepts and proposed design principles for an application for computer-based procedures (CBPs) for field operators in the nuclear domain (so-called handheld procedures). The concept is focused on the field operators' work with procedures and the communication and coordination between field operators and control room operators. The goal is to overcome challenges with shared situation awareness (SA) in a distributed team by providing effective and usable information design. An iterative design method and user-centred design is used for tailoring the concept to the context of field operations. The resulting concept supports the execution of procedures where close collaboration is needed between control room and field operations, e.g. where particular procedure steps are executed from remote control points and others from the control room. The resulting conceptual application for CBPs on handheld devices is developed for mitigating the SA challenges and designing for usability and ease of use.

  13. Performance of handheld electrocardiogram devices to detect atrial fibrillation in a cardiology and geriatric ward setting.

    Science.gov (United States)

    Desteghe, Lien; Raymaekers, Zina; Lutin, Mark; Vijgen, Johan; Dilling-Boer, Dagmara; Koopman, Pieter; Schurmans, Joris; Vanduynhoven, Philippe; Dendale, Paul; Heidbuchel, Hein

    2017-01-01

    To determine the usability, accuracy, and cost-effectiveness of two handheld single-lead electrocardiogram (ECG) devices for atrial fibrillation (AF) screening in a hospital population with an increased risk for AF. Hospitalized patients (n = 445) at cardiological or geriatric wards were screened for AF by two handheld ECG devices (MyDiagnostick and AliveCor). The performance of the automated algorithm of each device was evaluated against a full 12-lead or 6-lead ECG recording. All ECGs and monitor tracings were also independently reviewed in a blinded fashion by two electrophysiologists. Time investments by nurses and physicians were tracked and used to estimate cost-effectiveness of different screening strategies. Handheld recordings were not possible in 7 and 21.4% of cardiology and geriatric patients, respectively, because they were not able to hold the devices properly. Even after the exclusion of patients with an implanted device, sensitivity and specificity of the automated algorithms were suboptimal (Cardiology: 81.8 and 94.2%, respectively, for MyDiagnostick; 54.5 and 97.5%, respectively, for AliveCor; Geriatrics: 89.5 and 95.7%, respectively, for MyDiagnostick; 78.9 and 97.9%, respectively, for AliveCor). A scenario based on automated AliveCor evaluation in patients without AF history and without an implanted device proved to be the most cost-effective method, with a provider cost to identify one new AF patient of €193 and €82 at cardiology and geriatrics, respectively. The cost to detect one preventable stroke per year would be €7535 and €1916, respectively (based on average CHA 2 DS 2 -VASc of 3.9 ± 2.0 and 5.0 ± 1.5, respectively). Manual interpretation increases sensitivity, but decreases specificity, doubling the cost per detected patient, but remains cheaper than sole 12-lead ECG screening. Using AliveCor or MyDiagnostick handheld recorders requires a structured screening strategy to be effective and cost-effective in a hospital setting

  14. A data-driven design evaluation tool for handheld device soft keyboards.

    Directory of Open Access Journals (Sweden)

    Matthieu B Trudeau

    Full Text Available Thumb interaction is a primary technique used to operate small handheld devices such as smartphones. Despite the different techniques involved in operating a handheld device compared to a personal computer, the keyboard layouts for both devices are similar. A handheld device keyboard that considers the physical capabilities of the thumb may improve user experience. We developed and applied a design evaluation tool for different geometries of the QWERTY keyboard using a performance evaluation model. The model utilizes previously collected data on thumb motor performance and posture for different tap locations and thumb movement directions. We calculated a performance index (PITOT, 0 is worst and 2 is best for 663 designs consisting in different combinations of three variables: the keyboard's radius of curvature (R (mm, orientation (O (°, and vertical location on the screen (L. The current standard keyboard performed poorly (PITOT = 0.28 compared to other designs considered. Keyboard location (L contributed to the greatest variability in performance out of the three design variables, suggesting that designers should modify this variable first. Performance was greatest for designs in the middle keyboard location. In addition, having a slightly upward curve (R = -20 mm and orientated perpendicular to the thumb's long axis (O = -20° improved performance to PITOT = 1.97. Poorest performances were associated with placement of the keyboard's spacebar in the bottom right corner of the screen (e.g., the worst was for R = 20 mm, O = 40°, L =  Bottom (PITOT = 0.09. While this evaluation tool can be used in the design process as an ergonomic reference to promote user motor performance, other design variables such as visual access and usability still remain unexplored.

  15. Evolving Consumption Patterns of Various Information Media via Handheld Mobile Devices

    Directory of Open Access Journals (Sweden)

    Nitza Geri

    2015-06-01

    Full Text Available This study examines diverse information media in order to identify those formats that are most suitable for consumption via handheld mobile devices, namely, smartphones and tablets. The preferences of the users are measured objectively by analyzing actual data of their relative use of handheld mobile devices and personal computing (PC desktop devices, including laptops and notebooks, for consumption of information presented in various formats. Our findings are based on Google Analytics pageview data of five course Websites during a period of three semesters, by 11,557 undergraduate students. M-learning contexts were chosen, since in a learning environment the interests of information providers (i.e., the instructors are in accord with those of the information consumers (i.e., the students, whereas in commercial settings there may be conflicts of interests. Our findings demonstrate that although about 90% of the pageviews were via PC devices, the rate of smartphone use for consuming learning content in diverse information media is gradually increasing as time goes by, whereas the rate of tablet use for these purposes is stagnant. The most promising direction for smartphone development, emanating from the findings, is online video content.

  16. Application of handheld devices to field research among underserved construction worker populations: a workplace health assessment pilot study

    Directory of Open Access Journals (Sweden)

    Fleming Lora E

    2011-04-01

    Full Text Available Abstract Background Novel low-cost approaches for conducting rapid health assessments and health promotion interventions among underserved worker groups are needed. Recruitment and participation of construction workers is particularly challenging due to their often transient periods of work at any one construction site, and their limited time during work to participate in such studies. In the present methodology report, we discuss the experience, advantages and disadvantages of using touch screen handheld devices for the collection of field data from a largely underserved worker population. Methods In March 2010, a workplace-centered pilot study to examine the feasibility of using a handheld personal device for the rapid health assessment of construction workers in two South Florida Construction sites was undertaken. A 45-item survey instrument, including health-related questions on tobacco exposure, workplace safety practices, musculoskeletal disorders and health symptoms, was programmed onto Apple iPod Touch® devices. Language sensitive (English and Spanish recruitment scripts, verbal consent forms, and survey questions were all preloaded onto the handheld devices. The experience (time to survey administration and capital cost of the handheld administration method was recorded and compared to approaches available in the extant literature. Results Construction workers were very receptive to the recruitment, interview and assessment processes conducted through the handheld devices. Some workers even welcomed the opportunity to complete the questionnaire themselves using the touch screen handheld device. A list of advantages and disadvantages emerged from this experience that may be useful in the rapid health assessment of underserved populations working in a variety of environmental and occupational health settings. Conclusions Handheld devices, which are relatively inexpensive, minimize survey response error, and allow for easy storage of data

  17. Application of handheld devices to field research among underserved construction worker populations: a workplace health assessment pilot study.

    Science.gov (United States)

    Caban-Martinez, Alberto J; Clarke, Tainya C; Davila, Evelyn P; Fleming, Lora E; Lee, David J

    2011-04-01

    Novel low-cost approaches for conducting rapid health assessments and health promotion interventions among underserved worker groups are needed. Recruitment and participation of construction workers is particularly challenging due to their often transient periods of work at any one construction site, and their limited time during work to participate in such studies. In the present methodology report, we discuss the experience, advantages and disadvantages of using touch screen handheld devices for the collection of field data from a largely underserved worker population. In March 2010, a workplace-centered pilot study to examine the feasibility of using a handheld personal device for the rapid health assessment of construction workers in two South Florida Construction sites was undertaken. A 45-item survey instrument, including health-related questions on tobacco exposure, workplace safety practices, musculoskeletal disorders and health symptoms, was programmed onto Apple iPod Touch® devices. Language sensitive (English and Spanish) recruitment scripts, verbal consent forms, and survey questions were all preloaded onto the handheld devices. The experience (time to survey administration and capital cost) of the handheld administration method was recorded and compared to approaches available in the extant literature. Construction workers were very receptive to the recruitment, interview and assessment processes conducted through the handheld devices. Some workers even welcomed the opportunity to complete the questionnaire themselves using the touch screen handheld device. A list of advantages and disadvantages emerged from this experience that may be useful in the rapid health assessment of underserved populations working in a variety of environmental and occupational health settings. Handheld devices, which are relatively inexpensive, minimize survey response error, and allow for easy storage of data. These technological research modalities are useful in the

  18. Quality-Based Backlight Optimization for Video Playback on Handheld Devices

    Directory of Open Access Journals (Sweden)

    Liang Cheng

    2007-01-01

    Full Text Available For a typical handheld device, the backlight accounts for a significant percentage of the total energy consumption (e.g., around 30% for a Compaq iPAQ 3650. Substantial energy savings can be achieved by dynamically adapting backlight intensity levels on such low-power portable devices. In this paper, we analyze the characteristics of video streaming services and propose a cross-layer optimization scheme called quality adapted backlight scaling (QABS to achieve backlight energy savings for video playback applications on handheld devices. Specifically, we present a fast algorithm to optimize backlight dimming while keeping the degradation in image quality to a minimum so that the overall service quality is close to a specified threshold. Additionally, we propose two effective techniques to prevent frequent backlight switching, which negatively affects user perception of video. Our initial experimental results indicate that the energy used for backlight is significantly reduced, while the desired quality is satisfied. The proposed algorithms can be realized in real time.

  19. Implementation of synthetic aperture imaging on a hand-held device

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian; Kjeldsen, Thomas; Larsen, Lee

    2014-01-01

    -held devices all with different chipsets and a BK Medical UltraView 800 ultrasound scanner emulating a wireless probe. The wireless transmission is benchmarked using an imaging setup consisting of 269 scan lines x 1472 complex samples (1.58 MB pr. frame, 16 frames per second). The measured data throughput...... reached an average of 28.8 MB/s using a LG G2 mobile device, which is more than the required data throughput of 25.3 MB/s. Benchmarking the processing performance for B-mode imaging showed a total processing time of 18.9 ms (53 frames/s), which is less than the acquisition time (62.5 ms).......This paper presents several implementations of Syn- thetic Aperture Sequential Beamforming (SASB) on commer- cially available hand-held devices. The implementations include real-time wireless reception of ultrasound radio frequency sig- nals and GPU processing for B-mode imaging. The proposed...

  20. Rich internet application system for patient-centric healthcare data management using handheld devices.

    Science.gov (United States)

    Constantinescu, L; Pradana, R; Kim, J; Gong, P; Fulham, Michael; Feng, D

    2009-01-01

    Rich Internet Applications (RIAs) are an emerging software platform that blurs the line between web service and native application, and is a powerful tool for handheld device deployment. By democratizing health data management and widening its availability, this software platform has the potential to revolutionize telemedicine, clinical practice, medical education and information distribution, particularly in rural areas, and to make patient-centric medical computing a reality. In this paper, we propose a telemedicine application that leverages the ability of a mobile RIA platform to transcode, organise and present textual and multimedia data, which are sourced from medical database software. We adopted a web-based approach to communicate, in real-time, with an established hospital information system via a custom RIA. The proposed solution allows communication between handheld devices and a hospital information system for media streaming with support for real-time encryption, on any RIA enabled platform. We demonstrate our prototype's ability to securely and rapidly access, without installation requirements, medical data ranging from simple textual records to multi-slice PET-CT images and maximum intensity (MIP) projections.

  1. Design and Implementation of an Intelligent Windowsill System Using Smart Handheld Device and Fuzzy Microcontroller.

    Science.gov (United States)

    Wang, Jing-Min; Yang, Ming-Ta; Chen, Po-Lin

    2017-04-11

    With the advance of science and technology, people have a desire for convenient and comfortable living. Creating comfortable and healthy indoor environments is a major consideration for designing smart homes. As handheld devices become increasingly powerful and ubiquitous, this paper proposes an innovative use of smart handheld devices (SHD), using MIT App Inventor and fuzzy control, to perform the real-time monitoring and smart control of the designed intelligent windowsill system (IWS) in a smart home. A compact weather station that consists of environment sensors was constructed in the IWS for measuring of indoor illuminance, temperature-humidity, carbon dioxide (CO₂) concentration and outdoor rain and wind direction. According to the measured environment information, the proposed system can automatically send a command to a fuzzy microcontroller performed by Arduino UNO to fully or partly open the electric curtain and electric window for adapting to climate changes in the indoor and outdoor environment. Moreover, the IWS can automatically close windows for rain splashing on the window. The presented novel control method for the windowsill not only expands the SHD applications, but greatly enhances convenience to users. To validate the feasibility and effectiveness of the IWS, a laboratory prototype was built and confirmed experimentally.

  2. Textbooks on tap: using electronic books housed in handheld devices in nursing clinical courses.

    Science.gov (United States)

    Williams, Margaret G; Dittmer, Arlis

    2009-01-01

    Changing technology is creating new ways to approach nursing education and practice. Beginning in 2003, using a quasi-experimental design, this project introduced personal digital assistants (PDAs) as a clinical tool to five experimental and control groups of students and faculty. The handheld device, or PDA, was loaded with e-books for clinical practice. Differences in learning styles and preferences emerged during the different phases of the study. Students were quickly able to master the technology and use the device effectively, reporting that they liked the concise nature of the information obtained. No students expressed dissatisfaction or regret at being in the experimental group. Results and implications for clinical practice, education, and library resources are discussed.

  3. Mobile applications for handheld devices to screen and randomize acute stroke patients in clinical trials.

    Science.gov (United States)

    Qureshi, Ai; Connelly, B; Abbott, Ei; Maland, E; Kim, J; Blake, J

    2012-08-01

    The availability of internet connectivity and mobile application software used by low-power handheld devices makes smart phones of unique value in time-sensitive clinical trials. Trial-specific applications can be downloaded by investigators from various mobile software distribution platforms or web applications delivered over HTTP. The Antihypertensive Treatment in Acute Cerebral Hemorrhage (ATACH) II investigators in collaboration with MentorMate released the ATACH-II Patient Recruitment mobile application available on iPhone, Android, and Blackberry in 2011. The mobile application provides tools for pre-screening, assessment of eligibility, and randomization of patients. Since the release of ATACH-II mobile application, the CLEAR-IVH (Clot Lysis Evaluating Accelerated Resolution of Intraventricular Hemorrhage) trial investigators have also adopted such a mobile application. The video-conferencing capabilities of the most recent mobile devices open up additional opportunities to involve central coordinating centers in the recruitment process in real time.

  4. Assessment of computerized tomography devices in Minas Gerais state, Brazil

    International Nuclear Information System (INIS)

    Oliveira, Paulo Marcio C.; Horta, Mara Alice Avelar Saraiva; Santana, Priscila do Carmo; Magalhaes, Marcos Juliano

    2011-01-01

    Computed Tomography (CT) is the diagnostic imaging method most commonly performed today. It is a device that is undergoing a technological evolution and their quality control is sorely needed. The image quality evaluation process allow a better diagnosis and control of the patient dose received during image acquisition. The CT doses are higher than other X-ray examination techniques, like a conventional X-ray. Performance evaluation of computed tomography in Minas Gerais is not significant. Therefore, this work aims to analyze 20 CT equipment in Minas Gerais, with parameters according to the national regulatory agency (ANVISA - Agencia Nacional de Vigilancia Sanitaria) in twelve quality control tests. Sixty five percent (65%) of CT equipment evaluated showed excellent results and were not disapproved in any of the tests performed and 30% had failed in only one of the twelve tests performed. The worst result was found in the CT scanners in the test that evaluates the low contrast resolution, where 20% of CT showed non-compliance, followed by the test that evaluates the x-rays collimation beam, where 15% had failed. The tests allowed us to observe that the twenty computerized tomography equipment achieved a great pass rate. Considering that the evaluated CTs performed the quality control tests for the first time, it is concluded that the equipment used in clinics and hospitals are of good quality image and low radiation doses. (author)

  5. Comparison of Wearable Optical See-through and Handheld Devices as Platform for an Augmented Reality Museum Guide

    DEFF Research Database (Denmark)

    Serubugo, Sule; Skantarova, Denisa; Nielsen, Lasse Kjærsgård

    2017-01-01

    Self-service guides are a common way of providing information about artworks exhibited in museums. Modern advances in handheld mobile applications and wearable optical see-through devices that use augmented reality offer new ways of designing museum guides that are more engaging and interactive...... than traditional self-service guides such as written descriptions or audio guides. In this study we compare wearable (smart glasses) and handheld (smartphone) devices as a platform for an augmented reality museum guide. We have developed a museum guide for both a smartphone and smart glasses that can...... of potentials of these platforms as augmented reality museum guides and suggest promising future work....

  6. Portable (handheld) clinical device for quantitative spectroscopy of skin, utilizing spatial frequency domain reflectance techniques

    Science.gov (United States)

    Saager, Rolf B.; Dang, An N.; Huang, Samantha S.; Kelly, Kristen M.; Durkin, Anthony J.

    2017-09-01

    Spatial Frequency Domain Spectroscopy (SFDS) is a technique for quantifying in-vivo tissue optical properties. SFDS employs structured light patterns that are projected onto tissues using a spatial light modulator, such as a digital micromirror device. In combination with appropriate models of light propagation, this technique can be used to quantify tissue optical properties (absorption, μa, and scattering, μs', coefficients) and chromophore concentrations. Here we present a handheld implementation of an SFDS device that employs line (one dimensional) imaging. This instrument can measure 1088 spatial locations that span a 3 cm line as opposed to our original benchtop SFDS system that only collects a single 1 mm diameter spot. This imager, however, retains the spectral resolution (˜1 nm) and range (450-1000 nm) of our original benchtop SFDS device. In the context of homogeneous turbid media, we demonstrate that this new system matches the spectral response of our original system to within 1% across a typical range of spatial frequencies (0-0.35 mm-1). With the new form factor, the device has tremendously improved mobility and portability, allowing for greater ease of use in a clinical setting. A smaller size also enables access to different tissue locations, which increases the flexibility of the device. The design of this portable system not only enables SFDS to be used in clinical settings but also enables visualization of properties of layered tissues such as skin.

  7. Science education with handheld devices: A comparison of Nintendo WiiMote and iPod touch for kinematics learning

    OpenAIRE

    Hochberg, K.; Kuhn, J.; Müller, A.

    2016-01-01

    Experiential science learning based on the in-built sensors of handheld devices such as smartphones, tablet computer and game consoles has seen quite a strong development in recent years. In particular, such devices with internal acceleration sensors offer an innovative approach to kinematics learning in classroom physics, a notoriously difficult topic for pupils. In view of research and teaching in this domain, the practical advantages and disadvantages of two such devices, the Nintendo WiiM...

  8. Handheld juggernaut.

    Science.gov (United States)

    Hagland, Mark

    2010-08-01

    Not only are hospital, health system, and medical group ClOs and clinical informaticists deploying handheld mobile devices across their enterprises as clinical computing tools; clinicians, especially physicians, are increasingly bringing their own BlackBerrys, iPhones, iPads, Android devices, and other handhelds, into patient care organizations for their personal clinical use. Not surprisingly, the challenges--as well as the opportunities--are multilayered and complex, and include the strategic planning, infrastructure, clinician preference, clinician workflow, and security issues involved in the emerging mobile handheld revolution. The diversity of approaches among ClOs and other healthcare IT leaders on such issues is striking, and underscores the need for flexibility and nimbleness going forward.

  9. Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children

    Directory of Open Access Journals (Sweden)

    Janson C

    2006-04-01

    Full Text Available Abstract Background Exhaled nitric oxide (NO measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO was compared with a standard stationary chemiluminescence unit (NIOX. Methods A total of 71 subjects (6–60 years; 36 males, both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots, measurement feasibility (success rate with 6 attempts and repeatability (intrasubject SD. Results Success rate was high (≥ 84% in both devices for both adults and children. The subjects represented a FENO range of 8–147 parts per billion (ppb. When comparing the mean of three measurements (n = 61, the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. Conclusion The hand-held device (NIOX MINO and the stationary system (NIOX are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO is used. The hand-held device shows good repeatability, and it

  10. Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children.

    Science.gov (United States)

    Alving, K; Janson, C; Nordvall, L

    2006-04-20

    Exhaled nitric oxide (NO) measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO) was compared with a standard stationary chemiluminescence unit (NIOX). A total of 71 subjects (6-60 years; 36 males), both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s) in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots), measurement feasibility (success rate with 6 attempts) and repeatability (intrasubject SD). Success rate was high (> or = 84%) in both devices for both adults and children. The subjects represented a FENO range of 8-147 parts per billion (ppb). When comparing the mean of three measurements (n = 61), the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. The hand-held device (NIOX MINO) and the stationary system (NIOX) are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO) is used. The hand-held device shows good repeatability, and it can be used successfully on adults and most children

  11. Detection of cadmium sulphide nanoparticles by using screen-printed electrodes and a handheld device

    International Nuclear Information System (INIS)

    Merkoci, Arben; Marcolino-Junior, Luiz Humberto; MarIn, Sergio; Fatibello-Filho, Orlando; Alegret, Salvador

    2007-01-01

    A simple method based on screen-printed electrodes and a handheld potentiostatic device is reported for the detection of water soluble CdS quantum dots modified with glutathione. The detection method is based on the stripping of electrochemically reduced cadmium at pH 7.0 by using square wave voltammetry. Various parameters that affect the sensitivity of the method are optimized. QD suspension volumes of 20 μl and a number of around 2 x 10 11 CdS quantum dots have been able to be detected. The proposed method should be of special interest for bioanalytical assays, where CdS quantum dots can be used as electrochemical tracers

  12. User-friendly tools on handheld devices for observer performance study

    Science.gov (United States)

    Matsumoto, Takuya; Hara, Takeshi; Shiraishi, Junji; Fukuoka, Daisuke; Abe, Hiroyuki; Matsusako, Masaki; Yamada, Akira; Zhou, Xiangrong; Fujita, Hiroshi

    2012-02-01

    ROC studies require complex procedures to select cases from many data samples, and to set confidence levels in each selected case to generate ROC curves. In some observer performance studies, researchers have to develop software with specific graphical user interface (GUI) to obtain confidence levels from readers. Because ROC studies could be designed for various clinical situations, it is difficult task for preparing software corresponding to every ROC studies. In this work, we have developed software for recording confidence levels during observer studies on tiny personal handheld devices such as iPhone, iPod touch, and iPad. To confirm the functions of our software, three radiologists performed observer studies to detect lung nodules by using public database of chest radiograms published by Japan Society of Radiological Technology. The output in text format conformed to the format for the famous ROC kit from the University of Chicago. Times required for the reading each case was recorded very precisely.

  13. Detection of fecal contamination on beef meat surfaces using handheld fluorescence imaging device (HFID)

    Science.gov (United States)

    Oh, Mirae; Lee, Hoonsoo; Cho, Hyunjeong; Moon, Sang-Ho; Kim, Eun-Kyung; Kim, Moon S.

    2016-05-01

    Current meat inspection in slaughter plants, for food safety and quality attributes including potential fecal contamination, is conducted through by visual examination human inspectors. A handheld fluorescence-based imaging device (HFID) was developed to be an assistive tool for human inspectors by highlighting contaminated food and food contact surfaces on a display monitor. It can be used under ambient lighting conditions in food processing plants. Critical components of the imaging device includes four 405-nm 10-W LEDs for fluorescence excitation, a charge-coupled device (CCD) camera, optical filter (670 nm used for this study), and Wi-Fi transmitter for broadcasting real-time video/images to monitoring devices such as smartphone and tablet. This study aimed to investigate the effectiveness of HFID in enhancing visual detection of fecal contamination on red meat, fat, and bone surfaces of beef under varying ambient luminous intensities (0, 10, 30, 50 and 70 foot-candles). Overall, diluted feces on fat, red meat and bone areas of beef surfaces were detectable in the 670-nm single-band fluorescence images when using the HFID under 0 to 50 foot-candle ambient lighting.

  14. Computerized tomography

    International Nuclear Information System (INIS)

    Rubashov, I.B.

    1985-01-01

    Operating principle is described for the devices of computerized tomography used in medicine for diagnosis of brain diseases. Computerized tomography is considered as a part of computerized diagnosis, as a part of information science. It is shown that computerized tomography is a real existed field of investigations in medicine and industrial production

  15. Electrotactile Feedback for Handheld Devices with Touch Screen and Simulation of Roughness.

    Science.gov (United States)

    Altinsoy, M E; Merchel, S

    2012-01-01

    We present a novel electrotactile display that can be integrated into current handheld devices with touch screens. In this display, tactile information is presented to the fingertip of the user by transmitting small currents through electrodes. Experiments were conducted to investigate the perception of simulated textures using this electrotactile display technique. One fundamental feature of texture, which is the focus of this study, is roughness. The aim of the first experiment was to investigate the relationship between electrotactile stimulation parameters such as current and pulse frequency and the perception of roughness. An increase in the current magnitude resulted in an increase in perceived roughness. The aim of the second experiment was to investigate parameter combinations of electrotactile stimuli can be used to simulate textures. Subjects adjusted the intensity and frequency of the current stimuli until the simulated textures were perceived as being equal to reference textures such as sandpapers of varying grit numbers and grooved woods with varying groove widths. Subjects tended to find an electrotactile stimulus with a high current magnitude and a low pulse frequency more suitable to represent rough surfaces. They tended to find just-perceptible current magnitudes suitable for very smooth surfaces and did not show a preference for any frequency.

  16. Characterizing infantile hemangiomas with a near-infrared spectroscopic handheld wireless device

    Science.gov (United States)

    Fong, Christopher J.; Hoi, Jennifer W.; Kim, Hyun K.; Behr, Gerald; Geller, Lauren; Antonov, Nina; Flexman, Molly; Garzon, Maria; Hielscher, Andreas H.

    2015-03-01

    Infantile hemangiomas (IH) are common vascular growths that occur in 5-10% of neonates and have the potential to cause disfiguring and even life-threatening complications. Currently, no objective tool exist to monitor either progression or treatment of IH. To address this unmet clinical need, we have developed a handheld wireless device (HWD) that uses diffuse optical spectroscopy for the assessment of IH. The system employs 4 wavelengths (l=780nm, 805nm, 850nm, and 905nm) and 6 source-detector pairs with distances between 0.6 and 20 mm. Placed on the skin surface, backreflection data is obtained and a multispectral evolution algorithm is used to determine total hemoglobin concentration and tissue oxygen saturation. First results of an ongoing pilot study involving 13 patients (average enrollment age = 25 months) suggest that an increase in hypoxic stress over time can lead to the proliferation of IH. Involuting IH lesions showed an increase in tissue oxygen saturation as well as a decrease in total hemoglobin.

  17. Developing a compact multiple laser diode combiner with a single fiber stub output for handheld IoT devices

    Science.gov (United States)

    Lee, Minseok; June, Seunghyeok; Kim, Sehwan

    2018-01-01

    Many biomedical applications require an efficient combination and localization of multiple discrete light sources ( e.g., fluorescence and absorbance imaging). We present a compact 6 channel combiner that couples the output of independent solid-state light sources into a single 400-μm-diameter fiber stub for handheld Internet of Things (IoT) devices. We demonstrate average coupling efficiencies > 80% for each of the 6 laser diodes installed into the prototype. The design supports the use of continuous wave and intensity-modulated laser diodes. This fiber-stub-type beam combiner could be used to construct custom multi-wavelength sources for tissue oximeters, microscopes and molecular imaging technologies. In order to validate its suitability, we applied the developed fiber-stub-type beam combiner to a multi-wavelength light source for a handheld IoT device and demonstrated its feasibility for smart healthcare through a tumor-mimicking silicon phantom.

  18. Mobile Testing of Cognitive Function : A tool for assessment of cognitive abilities in an everyday environment using a handheld device

    OpenAIRE

    Fouchenette, Kim

    2011-01-01

    The unit of Cognitive Developmental Neuroscience at Karolinska Institutet have developed a method for measuring cognitive performance with handheld devices, which resulted in a mobile application for the iPod Touch. The application was previously used in a clinical trial with individuals suffering from chronic stress disorder, but had to be further developed. The application, which consisted of cognitive tests and questionnaires, required improvements that could be divided into three parts: (...

  19. Investigating Cross-Device Interaction between a Handheld Device and a Large Display

    DEFF Research Database (Denmark)

    Paay, Jeni; Raptis, Dimitrios; Kjeldskov, Jesper

    2017-01-01

    and mid-air gestures, pinching, swiping, swinging and flicking. We look specifically at their relative efficiency, effectiveness and accuracy in bi-directional interaction between a smartphone and large display in a point-click context. We report findings from two user studies, which show that swiping...... is both most effective, fastest and most accurate, closely followed by swinging. What these two approaches have in common is the ability to keep the pointer steady on the large display, unaffected by concurrent gestures or body movements used to complete the interaction, suggesting...... that this is an important factor for designing effective cross-device interaction with large displays....

  20. Comparison of a Handheld Indirect Calorimetry Device and Predictive Energy Equations Among Individuals on Maintenance Hemodialysis.

    Science.gov (United States)

    Morrow, Ellis A; Marcus, Andrea; Byham-Gray, Laura

    2017-11-01

    Practical methods for determining resting energy expenditure (REE) among individuals on maintenance hemodialysis (MHD) are needed because of the limitations of indirect calorimetry. Two disease-specific predictive energy equations (PEEs) have been developed for this metabolically complex population. The aim of this study was to compare estimated REE (eREE) by PEEs to measured REE (mREE) with a handheld indirect calorimetry device (HICD). A prospective pilot study of adults on MHD (N = 40) was conducted at 2 dialysis clinics in Houston and Texas City, Texas. mREE by an HICD was compared with eREE determined by 6 PEEs using Bland-Altman analysis with a band of acceptable agreement of ±10% of the group mean mREE. Paired t-test and the intraclass correlation coefficient were also used to compare the alternate methods of measuring REE. A priori alpha was set at P Maintenance Hemodialysis Equation-Creatinine version (MHCD-CR) was the most accurate PEE with 52.5% of values within the band of acceptable agreement, followed by the Mifflin-St. Jeor Equation and the Vilar et al. Equation at 45.0% and 42.5%, respectively. When compared with mREE by the HICD, the MHDE-CR was more accurate and precise than other PEEs evaluated; however, this must be interpreted with caution as mREE was consistently lower than eREE from all PEEs. Further research is needed to validate the MHDE-CR and other practical methods for determining REE among individuals on MHD. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  1. Home-based wrinkle reduction using a novel handheld multisource phase-controlled radiofrequency device.

    Science.gov (United States)

    Shemer, Avner; Levy, Hanna; Sadick, Neil S; Harth, Yoram; Dorizas, Andrew S

    2014-11-01

    In the last decade, energy-based aesthetic treatments, using light, radiofrequency (RF), and ultrasound, have gained scientific acceptance as safe and efficacious for non-invasive treatment for aesthetic skin disorders. The phase-controlled multisource radiofrequency technology (3DEEP™), which is based on the simultaneous use of multiple RF generators, was proven to allow significant pigment-independent dermal heating without pain or the need of epidermal cooling. This study was performed in order to evaluate the efficacy and safety of a new handheld device delivering multisource radiofrequency to the skin for wrinkle reduction and skin tightening in the home setting. A total of 69 participants (age 54.3 years ± 8.09; age range 37-72 years) were enrolled in the study after meeting all inclusion/exclusion criteria (100%) and providing informed consent. Participants were provided with the tested device together with a user manual and treatment diary, to perform independent treatments at home for 4 weeks. The tested device, (Newa™, EndyMed Medical, Cesarea, Israel) emits 12 W of 1Mhz, RF energy through six electrodes arranged in a linear fashion. Independent control of RF polarity through each one of the 6 electrodes allows significant reduction of energy flow through the epidermis with increased dermal penetration. Participants were instructed to perform at least 5 treatments a week, for one month. Four follow-up visits were scheduled (once a week) during the period of independent treatments at home, following 4 weeks of home treatments, 1 month follow-up visit (1 month after treatment end) and at 3 months follow-up (3 months following treatment end). Analysis of pre-and post treatment images was conducted by three uninvolved physicians experienced with the Fitzpatrick Wrinkle and Elastosis Scale. Fitzpatrick Wrinkle and Elastosis score of each time point (4 weeks following home use treatments; 1 month follow-up, 3 months follow-up) was compared to baseline

  2. Evaluation of cone function by a handheld non-mydriatic flicker electroretinogram device

    Directory of Open Access Journals (Sweden)

    Nakamura N

    2016-06-01

    Full Text Available Natsuko Nakamura,1 Kaoru Fujinami,1 Yoshinobu Mizuno,2 Toru Noda,2 Kazushige Tsunoda11Laboratory of Visual Physiology, Division of Vision Research, National Institute of Sensory Organs, 2Department of Ophthalmology, National Hospital Organization, National Tokyo Medical Center, Tokyo, JapanPurpose: Full-field electroretinograms (ERGs are used to evaluate retinal function in patients with various types of hereditary and acquired retinal diseases. However, ERG recordings require relatively invasive procedures, including pupillary dilation and the use of contact lens electrodes. Thus, it would be helpful to have a simpler and noninvasive screening method. The purpose of this study was to determine whether a new, handheld, portable ERG device, RETeval™, can be used to screen patients for cone dysfunction.Patients and methods: Thirty-five eyes of 35 patients who had reduced cone responses ascertained by a conventional ERG system using contact lens electrodes were studied. The causative diseases included achromatopsia, cone dystrophy, cone-rod dystrophy, retinitis pigmentosa, choroidal dystrophy, autoimmune retinopathy, and Stargardt disease. The flicker ERGs were recorded with the RETeval™ under undilated conditions with skin electrodes (stimulus strength, 3.0 cd·s/m2; frequency, 28.3 Hz, and the responses were compared to that of 50 healthy eyes. The amplitudes and implicit times of the fundamental component of the flicker ERGs were analyzed in three age groups: Group A, ≤20 years; Group B, 21–40 years; and Group C, ≥41 years.Results: In all of the age groups, the amplitudes of the ERGs were significantly smaller and the implicit times significantly longer in patients with cone dysfunction than in the control eyes. All but one of the patients had flicker amplitudes lower than the mean −2.0 standard deviation of control eyes.Conclusion: The RETeval™ has a potential of being used to screen for cone dysfunction. The entire examination

  3. 76 FR 22918 - In the Matter of Certain Handheld Electronic Computing Devices, Related Software, and Components...

    Science.gov (United States)

    2011-04-25

    ... INTERNATIONAL TRADE COMMISSION [Inv. No. 337-TA-769] In the Matter of Certain Handheld Electronic.... International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that a complaint was filed with the U.S. International Trade Commission on March 21, 2011, under section 337 of the Tariff Act of 1930...

  4. Clinical effectiveness of the Respimat® inhaler device in managing chronic obstructive pulmonary disease: evidence when compared with other handheld inhaler devices

    Directory of Open Access Journals (Sweden)

    et al

    2011-02-01

    Full Text Available Felix SF Ram1, Celso R Carvallho2, John White31School of Health and Social Services, Massey University, Auckland, New Zealand; 2Department of Physical Therapy, School of Medicine, University of São Paulo, Brazil; 3York Hospitals NHS Foundation Trust, York Hospital, York, UKObjectives: Medication for the management of chronic obstructive pulmonary disease (COPD may be delivered by a number of different inhaler devices. This study was undertaken to determine the clinical effectiveness of the Respimat® handheld inhaler device compared with other handheld inhaler devices for the delivery of medication in stable COPD.Methodology: A systematic review of high-quality randomized controlled clinical trials comparing Respimat with other inhaler devices using the same medication was performed. Studies were searched for in the Cochrane Central Register of Controlled Trials as well as other relevant electronic databases. Manufacturers of inhaled COPD medication were also contacted for potential trials.Results: Seven studies of high methodological quality with 3813 participants were included in the review. Three trials used Handihaler® as the comparator inhaler, three used a chlorofluorocarbon metered-dose inhaler (CFC-MDI, and one trial used a hydroflouroalkane (HFA-MDI. When Respimat was compared with Handihaler, the following reported outcomes were not significantly different: trough forced expiratory volume in 1 second (FEV1 (weighted mean difference [WMD] 0.01 L; P = 0.14, trough forced vital capacity (FVC (WMD 0.001 L: P = 0.88, peak FEV1 (WMD 0.01 L: P = 0.08, peak FVC (WMD 0.01 L: P = 0.55, morning peak expiratory flow rate (PEFR (WMD 5.06 L/min: P = 0.08, and evening PEFR (WMD 4.39 L/min: P = 0.15. Furthermore, there were no differences when Respimat was compared with Handihaler for risk of exacerbations (relative risk [RR] 0.94: P = 0.81, dry mouth (RR 1.57: P = 0.34, or nasopharyngitis (RR 1.42: P = 0.22. For Respimat compared with CFC-MDI, the

  5. Handheld Devices and Video Modeling to Enhance the Learning of Self-Help Skills in Adolescents With Autism Spectrum Disorder.

    Science.gov (United States)

    Campbell, Joseph E; Morgan, Michele; Barnett, Veronica; Spreat, Scott

    2015-04-01

    The viewing of videos is a much-studied intervention to teach self-help, social, and vocational skills. Many of the studies to date looked at video modeling using televisions, computers, and other large screens. This study looked at the use of video modeling on portable handheld devices to teach hand washing to three adolescent students with an autism spectrum disorder. Three students participated in this 4-week study conducted by occupational therapists. Baseline data were obtained for the first student for 1 week, the second for 2 weeks, and the third for 3 weeks; videos were introduced when the participants each finished the baseline phase. Given the cognitive and motor needs of the participants, the occupational therapist set the player so that the participants only had to press the play button to start the video playing. The participants were able to hold the players and view at distances that were most appropriate for their individual needs and preferences. The results suggest that video modeling on a handheld device improves the acquisition of self-help skills.

  6. ITSY Handheld Software Radio

    National Research Council Canada - National Science Library

    Bose, Vanu

    2001-01-01

    .... A handheld software radio platform would enable the construction of devices that could inter-operate with multiple legacy systems, download new waveforms and be used to construct adhoc networks...

  7. Integrating bar-code devices with computerized MC and A systems

    International Nuclear Information System (INIS)

    Anderson, L.K.; Boor, M.G.; Hurford, J.M.

    1998-01-01

    Over the past seven years, Los Alamos National Laboratory developed several generations of computerized nuclear materials control and accountability (MC and A) systems for tracking and reporting the storage, movement, and management of nuclear materials at domestic and international facilities. During the same period, Oak Ridge National Laboratory was involved with automated data acquisition (ADA) equipment, including installation of numerous bar-code scanning stations at various facilities to serve as input devices to computerized systems. Bar-code readers, as well as other ADA devices, reduce input errors, provide faster input, and allow the capture of data in remote areas where workstations do not exist. Los Alamos National Laboratory and Oak Ridge National Laboratory teamed together to implement the integration of bar-code hardware technology with computerized MC and A systems. With the expertise of both sites, the two technologies were successfully merged with little difficulty. Bar-code input is now available with several functions of the MC and A systems: material movements within material balance areas (MBAs), material movements between MBAs, and physical inventory verification. This paper describes the various components required for the integration of these MC and A systems with the installed bar-code reader devices and the future directions for these technologies

  8. Handheld Devices with Wide-Area Wireless Connectivity: Applications in Astronomy Educational Technology and Remote Computational Control

    Science.gov (United States)

    Budiardja, R. D.; Lingerfelt, E. J.; Guidry, M. W.

    2003-05-01

    Wireless technology implemented with handheld devices has attractive features because of the potential to access large amounts of data and the prospect of on-the-fly computational analysis from a device that can be carried in a shirt pocket. We shall describe applications of such technology to the general paradigm of making digital wireless connections from the field to upload information and queries to network servers, executing (potentially complex) programs and controlling data analysis and/or database operations on fast network computers, and returning real-time information from this analysis to the handheld device in the field. As illustration, we shall describe several client/server programs that we have written for applications in teaching introductory astronomy. For example, one program allows static and dynamic properties of astronomical objects to be accessed in a remote observation laboratory setting using a digital cell phone or PDA. Another implements interactive quizzing over a cell phone or PDA using a 700-question introductory astronomy quiz database, thus permitting students to study for astronomy quizzes in any environment in which they have a few free minutes and a digital cell phone or wireless PDA. Another allows one to control and monitor a computation done on a Beowulf cluster by changing the parameters of the computation remotely and retrieving the result when the computation is done. The presentation will include hands-on demonstrations with real devices. *Managed by UT-Battelle, LLC, for the U.S. Department of Energy under contract DE-AC05-00OR22725.

  9. User certification of hand-held x-ray tube based analytical fluorescent devices in a canadian context

    International Nuclear Information System (INIS)

    Maharaj, H.P.

    2005-01-01

    Safety education aims to reduce personal injury and improve well being. This health promotion principle is applied in the case of hand-held open beam x-ray tube based analytical x-ray devices. Such devices not only are light weight and portable, but also present high radiation exposure levels at the beam exit port and potentially can be used in a variety of industrial applications for determination of material composition. There is much potential for radiation risks to occur with resultant adverse effects if such devices are not used by trained individuals within controlled environments. A level of radiation safety knowledge and understanding of the device design, construction and performance characteristics appear warranted. To reduce radiation risks, user certification at a federal level was introduced in 2004 based on International Standards Organization 20807, since that standard comprises elements commensurate with risk reduction strategies. Within these contexts, a federally certified user is deemed to have acquired a level of safety knowledge and skills to facilitate safe use of the device. Certification, however, does not absolve the holder from obligations of compliance with applicable provincial, territorial or federal laws respecting device operation. The union of federal certification and applicable legislative mandated operational criteria reduces radiation risks overall. (author)

  10. Prevalence and risk factors associated with musculoskeletal complaints among users of mobile handheld devices: A systematic review.

    Science.gov (United States)

    Xie, Yanfei; Szeto, Grace; Dai, Jie

    2017-03-01

    This systematic review aimed at evaluating the prevalence and risk factors for musculoskeletal complaints associated with mobile handheld device use. Pubmed, Medline, Web of Science, CINAHL and Embase were searched. The methodological quality of included studies was assessed. Strength of evidence for risk factors was determined based on study designs, methodological quality and consistency of results. Five high-quality, eight acceptable-quality and two low-quality peer-reviewed articles were included. This review demonstrates that the prevalence of musculoskeletal complaints among mobile device users ranges from 1.0% to 67.8% and neck complaints have the highest prevalence rates ranging from 17.3% to 67.8%. This study also finds some evidence for neck flexion, frequency of phone calls, texting and gaming in relation to musculoskeletal complaints among mobile device users. Inconclusive evidence is shown for other risk factors such as duration of use and human-device interaction techniques due to inconsistent results or a limited number of studies. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Feasibility of using a handheld electronic device for the collection of patient reported outcomes data from children.

    Science.gov (United States)

    Vinney, Lisa A; Grade, John D; Connor, Nadine P

    2012-01-01

    The manner in which a communication disorder affects health-related quality of life (QOL) in children is not known. Unfortunately, collection of quality of life data via traditional paper measures is labor intensive and has several other limitations, which hinder the investigation of pediatric quality of life in children. Currently, there is not sufficient research regarding the use of electronic devices to collect pediatric patient reported outcomes in order to address such limitations. Thus, we used a cross-over design to compare responses to a pediatric health quality of life instrument (PedsQL 4.0) delivered using a handheld electronic device to those from a traditional paper form. Respondents were children with (n=9) and without (n=10) a speech or voice disorder. For paper versus the electronic format, we examined time to completion, number of incomplete or inaccurate question responses, intra-rater reliability, ease of use, and child and parent preference. There were no significant differences between children's scores, time to complete the measure, or ratings related to ease of answering questions. The percentage of children who made answering errors or omissions with paper and pencil was significantly greater than the percentage of children who made such errors using the device. This preliminary study demonstrated that use of an electronic device to collect QOL or patient-reported outcomes (PRO) data from children is more efficient than and just as feasible, reliable, and acceptable as using paper forms. The development of hardware and software applications for the collection of QOL and/or PRO data in children with speech disorders is likely warranted. The reader will be able to understand: (1) The potential benefits of using electronic data capture via handheld devices for collecting pediatric patient reported outcomes; (2) The Pediatric Quality of Life Inventory 4.0 is a measure of the perception of general health quality that has distinguished between

  12. Examining Mobile Technology in Higher Education: Handheld Devices in and out of the Classroom

    Science.gov (United States)

    Mueller, Julie; Wood, Eileen; De Pasquale, Domenica; Cruikshank, Ruth

    2012-01-01

    This study followed an innovative introduction of mobile technology (i.e., BlackBerry® devices) to a graduate level business program and documented students' use of the technology from the time students received the devices to the end of their first term of study. Students found the BlackBerry® device easy to use, and were optimistic regarding its…

  13. Flexible CMOS low-noise amplifiers for beyond-3G wireless hand-held devices

    Science.gov (United States)

    Becerra-Alvarez, Edwin C.; Sandoval-Ibarra, Federico; de la Rosa, José M.

    2009-05-01

    This paper explores the use of reconfigurable Low-Noise Amplifiers (LNAs) for the implementation of CMOS Radio Frequency (RF) front-ends in the next generation of multi-standard wireless transceivers. Main circuit strategies reported so far for multi-standard LNAs are reviewed and a novel flexible LNA intended for Beyond-3G RF hand-held terminals is presented. The proposed LNA circuit consists of a two-stage topology that combines inductive-source degeneration with PMOS-varactor based tuning network and a programmable load to adapt its performance to different standard specifications without penalizing the circuit noise and with a reduced number of inductors as compared to previous reported reconfigurable LNAs. The circuit has been designed in a 90-nm CMOS technology to cope with the requirements of the GSM, WCDMA, Bluetooth and WLAN (IEEE 802.11b-g) standards. Simulation results, including technology and packaging parasitics, demonstrate correct operation of the circuit for all the standards under study, featuring NF13.3dB and IIP3>10.9dBm, over a 1.85GHz-2.4GHz band, with an adaptive power consumption between 17mW and 22mW from a 1-V supply voltage. Preliminary experimental measurements are included, showing a correct reconfiguration operation within the operation band.

  14. Effects of Video Caption Modes on English Listening Comprehension and Vocabulary Acquisition Using Handheld Devices

    Science.gov (United States)

    Hsu, Ching-Kun; Hwang, Gwo-Jen; Chang, Yu-Tzu; Chang, Chih-Kai

    2013-01-01

    This study investigates the effects of different display modes of video captions on mobile devices, including non-caption, full-caption, and target-word modes, on the English comprehension and vocabulary acquisition of fifth graders. During the one-month experiment, the status of the students' English listening comprehension and vocabulary…

  15. Real-time Identification System using Mobile Hand-held Devices: Mobile Biometrics Evaluation Framework

    Science.gov (United States)

    2014-04-01

    test server, transmit five test cases over both WIFI and 3G , and receive accurate results. The second Study output, the Mobile Biometrics Evaluation...wired (USB), near field (Bluetooth), wireless (802.11) and cellular ( 2G / 3G ) connectivity. Satellite (BGAN) devices have been deployed, in conjunction...Wireless Connectivity: 802.11b, 802.11g, Bluetooth Cellular Connectivity: GSM [ 2G ], UMTS [ 3G ] Internal RAM (GB): 128 Internal Storage (GB): 128

  16. Initial Experience with a Handheld Device Digital Imaging and Communications in Medicine Viewer: OsiriX Mobile on the iPhone

    OpenAIRE

    Choudhri, Asim F.; Radvany, Martin G.

    2010-01-01

    Medical imaging is commonly used to diagnose many emergent conditions, as well as plan treatment. Digital images can be reviewed on almost any computing platform. Modern mobile phones and handheld devices are portable computing platforms with robust software programming interfaces, powerful processors, and high-resolution displays. OsiriX mobile, a new Digital Imaging and Communications in Medicine viewing program, is available for the iPhone/iPod touch platform. This raises the possibility o...

  17. Design of a Template for Handwriting Based Hindi Text Entry in Handheld Devices

    Science.gov (United States)

    Gangopadhyay, Diya; Vasal, Ityam; Yammiyavar, Pradeep

    Mobile phones, in the recent times, have become affordable and accessible to a wider range of users including the hitherto technologically and economically under-represented segments. Indian users are a gigantic consumer base for mobile phones. With Hindi being one of the most widely spoken languages in the country and the primary tool of communication for about a third of its population, an effective solution for Hindi text entry in mobile devices is expected to be immensely useful to the non English speaking users. This paper proposes a mobile phone handwriting based text entry solution for Hindi language, which allows for an easy text entry method, while facilitating better recognition accuracy.

  18. Measurement of Visual Reaction Times Using Hand-held Mobile Devices

    Science.gov (United States)

    Mulligan, Jeffrey B.; Arsintescu, Lucia; Flynn-Evans, Erin

    2015-01-01

    Modern mobile devices provide a convenient platform for collecting research data in the field. But,because the working of these devices is often cloaked behind multiple layers of proprietary system software, it can bedifficult to assess the accuracy of the data they produce, particularly in the case of timing. We have been collecting datain a simple visual reaction time experiment, as part of a fatigue testing protocol known as the Psychomotor Vigilance Test (PVT). In this protocol, subjects run a 5-minute block consisting of a sequence of trials in which a visual stimulus appears after an unpredictable variable delay. The subject is required to tap the screen as soon as possible after the appearance of the stimulus. In order to validate the reaction times reported by our program, we had subjects perform the task while a high-speed video camera recorded both the display screen, and a side view of the finger (observed in a mirror). Simple image-processing methods were applied to determine the frames in which the stimulus appeared and disappeared, and in which the finger made and broke contact with the screen. The results demonstrate a systematic delay between the initial contact by the finger and the detection of the touch by the software, having a value of 80 +- 20 milliseconds.

  19. Assessing the accommodation response after near visual tasks using different handheld electronic devices

    Directory of Open Access Journals (Sweden)

    Aikaterini I. Moulakaki

    Full Text Available ABSTRACT Purpose: To assess the accommodation response after short reading periods using a tablet and a smartphone as well as determine potential differences in the accommodation response at various stimulus vergences using a Hartmann- Shack aberrometer. Methods: Eighteen healthy subjects with astigmatism of less than 1 D, corrected visual acuity of 20/20 or better, and normal findings in an ophthalmic examination were enrolled. Accommodation responses were obtained under three different conditions: accommodation system of the eye relaxed and visually stressed with a tablet and an smartphone for 10 min, at a distance of 0.25 m from the subject's eyes. Three measurements of accommodation response were monocularly acquired at stimulus vergences ranging from 0 to 4 D (1-D step. Results: No statistically significant differences were found in the accommodation responses among the conditions. A moderate but gradually increasing root mean square, coma-like aberration was found for every condition. Conversely, the spherical aberration decreased as stimulus vergences increased. These outcomes were identified in comparison to the one-to-one ideal accommodation response, implying that a certain lag value was present in all stimulus vergences different from 0 D. Conclusions: The results support the hypothesis that the difference between the ideal and real accommodation responses is mainly attributed to parameters associated with the accommodation process, such as the near visual acuity, depth of focus, pupil diameter, and wavefront aberrations. The wavefront aberrations were dependent on the 3-mm pupil size selected in this study. The accommoda tion response was not dependent on the electronic device employed in each condition, and it was mainly associated with young age and level of amplitude of accommodation of the subjects.

  20. A new approach for the screening of carotid lesions: a 'fast-track' method with the use of new generation hand-held ultrasound devices.

    Science.gov (United States)

    Aboyans, V; Lacroix, P; Jeannicot, A; Guilloux, J; Bertin, F; Laskar, M

    2004-09-01

    We assessed the usefulness of fast-track neck sonography with a new-generation hand-held ultrasound scanner in the detection of > or =60% carotid stenosis. Patients with a past history of atherosclerotic disease or presence of risk factors were enrolled. All had fast-track carotid screening with a hand-held ultrasound scanner. Initial assessment was performed with our quick imaging protocol. A second examiner performed a conventional complete carotid duplex as gold-standard. We enrolled 197 consecutive patients with a mean age of 67 years (range 35-94). A carotid stenosis >60% was detected in 13 cases (6%). The sensitivity, specificity, positive and negative predictive value of fast-track sonography was 100%, 64%, 17% and 100%, respectively. Concomitant power Doppler imaging during the fast-track method did not improve accuracy. The use of a fast-track method with a hand-held ultrasound device can reduce the number of unnecessary carotid Duplex and enhance the screening efficiency without missing significant carotid stenoses.

  1. Handheld and automated ultrasonic spray deposition of conductive PEDOT:PSS films and their application in AC EL devices

    NARCIS (Netherlands)

    Ely, Fernando; Matsumoto, Agatha; Zoetebier, Bram; Peressinotto, Valdirene S.; Hirata, Marcelo Kioshi; de Sousa, Douglas A.; Maciel, Rubens

    2014-01-01

    In this contribution we explore the spray deposition technique to achieve smooth films based on the conductive polymer PEDOT:PSS. Two different spray systems were used and compared namely: (a) handheld airbrush and (b) automated ultrasonic spray system. For each system a number of parameters were

  2. Initial experience with a handheld device digital imaging and communications in medicine viewer: OsiriX mobile on the iPhone.

    Science.gov (United States)

    Choudhri, Asim F; Radvany, Martin G

    2011-04-01

    Medical imaging is commonly used to diagnose many emergent conditions, as well as plan treatment. Digital images can be reviewed on almost any computing platform. Modern mobile phones and handheld devices are portable computing platforms with robust software programming interfaces, powerful processors, and high-resolution displays. OsiriX mobile, a new Digital Imaging and Communications in Medicine viewing program, is available for the iPhone/iPod touch platform. This raises the possibility of mobile review of diagnostic medical images to expedite diagnosis and treatment planning using a commercial off the shelf solution, facilitating communication among radiologists and referring clinicians.

  3. Computerized Neuropsychological Assessment Devices: Joint Position Paper of the American Academy of Clinical Neuropsychology and the National Academy of Neuropsychology†

    Science.gov (United States)

    Bauer, Russell M.; Iverson, Grant L.; Cernich, Alison N.; Binder, Laurence M.; Ruff, Ronald M.; Naugle, Richard I.

    2012-01-01

    This joint position paper of the American Academy of Clinical Neuropsychology and the National Academy of Neuropsychology sets forth our position on appropriate standards and conventions for computerized neuropsychological assessment devices (CNADs). In this paper, we first define CNADs and distinguish them from examiner-administered neuropsychological instruments. We then set forth position statements on eight key issues relevant to the development and use of CNADs in the healthcare setting. These statements address (a) device marketing and performance claims made by developers of CNADs; (b) issues involved in appropriate end-users for administration and interpretation of CNADs; (c) technical (hardware/software/firmware) issues; (d) privacy, data security, identity verification, and testing environment; (e) psychometric development issues, especially reliability, and validity; (f) cultural, experiential, and disability factors affecting examinee interaction with CNADs; (g) use of computerized testing and reporting services; and (h) the need for checks on response validity and effort in the CNAD environment. This paper is intended to provide guidance for test developers and users of CNADs that will promote accurate and appropriate use of computerized tests in a way that maximizes clinical utility and minimizes risks of misuse. The positions taken in this paper are put forth with an eye toward balancing the need to make validated CNADs accessible to otherwise underserved patients with the need to ensure that such tests are developed and utilized competently, appropriately, and with due concern for patient welfare and quality of care. PMID:22382386

  4. Suitability of capillary blood obtained by a minimally invasive lancet technique to detect subclinical ketosis in dairy cows by using 3 different electronic hand-held devices.

    Science.gov (United States)

    Kanz, P; Drillich, M; Klein-Jöbstl, D; Mair, B; Borchardt, S; Meyer, L; Schwendenwein, I; Iwersen, M

    2015-09-01

    The objective of this study was to evaluate the suitability of capillary blood obtained by a minimally invasive lancet technique to detect subclinical ketosis in 49 prepartum and 191 postpartum Holstein-Friesian cows using 3 different electronic hand-held devices [FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini), NovaVet (NOV, Nova Biomedical)]. The β-hydroxybutyrate (BHBA) concentration in serum harvested from coccygeal blood samples was analyzed in a laboratory and used as a reference value. Capillary samples were obtained from the skin of the exterior vulva by using 1 of 3 different lancets. In all samples, the concentration of BHBA was immediately analyzed with all 3 hand-held devices used in random order. All lancets used in the study were eligible for capillary blood collection but differed in the total number of incisions needed. Spearman correlation coefficients between the BHBA concentrations in capillary blood and the reference test were highly significant with 83% for the FSP, 73% for the NOV, and 63% for the GLX. Using capillary blood, the FSP overestimated the mean BHBA concentration compared with the reference test (+0.08 mmol/L), whereas the GLX and NOV underestimated the mean concentration (-0.07 and -0.01 mmol/L). When a BHBA concentration of 1.2 mmol/L in serum was used to define subclinical ketosis, the corresponding analyses of receiver operating characteristics resulted in optimized thresholds for capillary blood of 1.1 mmol/L for the NOV and GLX devices, and of 1.0 mmol/L for the FSP. Based on these thresholds, sensitivities (Se) and specificities (Sp) were 89 and 84% for the NOV, 80 and 89% for the GLX, and 100 and 76% for the FSP. Based on a serum BHBA concentration of 1.4 mmol/L, analyses of receiver operating characteristics resulted in optimized cut-offs of 1.4 mmol/L for the FSP (Se 100%, Sp 92%), 1.3 mmol/L for the NOV (Se 80%, Sp 95%), and 1.1 mmol/L (Se 90%, Sp 85%) for the GLX. Using these optimized thresholds

  5. Thresholds of whole-blood β-hydroxybutyrate and glucose concentrations measured with an electronic hand-held device to identify ovine hyperketonemia.

    Science.gov (United States)

    Pichler, M; Damberger, A; Schwendenwein, I; Gasteiner, J; Drillich, M; Iwersen, M

    2014-03-01

    Metabolic disorders, especially hyperketonemia, are very common in dairy sheep. The whole-blood concentrations of β-hydroxybutyrate (BHBA) and glucose can be determined by commercially available electronic hand-held devices, which are used in human medicine and for the detection of ketosis in dairy cows. The aim of this study was to evaluate the suitability of the hand-held device Precision Xceed (PX; Abbott Diabetes Care Inc., Abbott Park, IL) to detect hyperketonemia in ewes. An additional objective of this study was to evaluate the agreement between samples obtained by minimal invasive venipuncture of an ear vein and measurements of whole-blood samples from the jugular vein (vena jugularis, v. jug.). Blood samples taken from the v. jug. were collected from 358 ewes on 4 different farms. These samples and a blood drop obtained from an ear vein were analyzed simultaneously on farm with the PX. For method comparison, the samples obtained from the v. jug. were also analyzed by standard methods, which served as the gold standard at the Central Laboratory of the University of Veterinary Medicine Vienna, Austria. The correlation coefficients between the serum BHBA concentration and the concentrations measured with the hand-held meter in the whole blood from an ear vein and the v. jug. were 0.94 and 0.96, respectively. The correlation coefficients of plasma and whole-blood glucose concentration were 0.68 for the v. jug. and 0.47 for the ear vein. The mean glucose concentration was significantly lower in animals classified as hyperketonemic (BHBA ≥ 1.6 mmol/L) compared with healthy ewes. Whole-blood concentrations of BHBA and glucose measured with the PX from v. jug. showed a constant negative bias of 0.15 mmol/L and 8.4 mg/dL, respectively. Hence, a receiver operating characteristic analysis was performed to determine thresholds for the PX to detect hyperketonemia in ewes. This resulted in thresholds for moderate ketosis of BHBA concentrations of 0.7 mmol/L in blood

  6. Measuring irradiated lung and heart area in breast tangential fields using a simulator-based computerized tomography device

    Energy Technology Data Exchange (ETDEWEB)

    Mallik, Raj; Fowler, Allan; Hunt, Peter

    1995-01-15

    Purpose: To illustrate the use of a simulator based computerized tomography system (SIMCT) in the simulation and planning of tangential breast fields. Methods and Materials: Forty-five consecutive patients underwent treatment planning using a radiotherapy simulator with computerized tomography attachment. One to three scans were obtained for each patient, calculations were made on the central axis scan. Due to the wide aperture of this system all patients were able to be scanned in the desired treatment position with arm abducted 90 deg. . Using available software tools the area of lung and/or heart included within the tangential fields was calculated. The greatest perpendicular distance (GPD) from the chest wall to posterior field edge was also measured. Results: The mean GPD for the group was 25.40 mm with 71% of patients having GPDs of {<=} 30 mm. The mean area of irradiated lung was 1780 sq mm which represented 18.0% of the total ipsilateral lung area seen in the central axis. Seven of the patients with left sided tumors had an average 1314 sq mm heart irradiated in the central axis. This represented 11.9% of total heart area in these patients. Conclusion: Measurements of irradiated lung and heart area can be easily and accurately made using a SIMCT device. Such measurements may help identify those patients potentially at risk for lung or heart toxicity as a consequence of their treatment. A major advantage of this device is the ability to scan patients in the actual treatment position.

  7. Measuring irradiated lung and heart area in breast tangential fields using a simulator-based computerized tomography device

    International Nuclear Information System (INIS)

    Mallik, Raj; Fowler, Allan; Hunt, Peter

    1995-01-01

    Purpose: To illustrate the use of a simulator based computerized tomography system (SIMCT) in the simulation and planning of tangential breast fields. Methods and Materials: Forty-five consecutive patients underwent treatment planning using a radiotherapy simulator with computerized tomography attachment. One to three scans were obtained for each patient, calculations were made on the central axis scan. Due to the wide aperture of this system all patients were able to be scanned in the desired treatment position with arm abducted 90 deg. . Using available software tools the area of lung and/or heart included within the tangential fields was calculated. The greatest perpendicular distance (GPD) from the chest wall to posterior field edge was also measured. Results: The mean GPD for the group was 25.40 mm with 71% of patients having GPDs of ≤ 30 mm. The mean area of irradiated lung was 1780 sq mm which represented 18.0% of the total ipsilateral lung area seen in the central axis. Seven of the patients with left sided tumors had an average 1314 sq mm heart irradiated in the central axis. This represented 11.9% of total heart area in these patients. Conclusion: Measurements of irradiated lung and heart area can be easily and accurately made using a SIMCT device. Such measurements may help identify those patients potentially at risk for lung or heart toxicity as a consequence of their treatment. A major advantage of this device is the ability to scan patients in the actual treatment position

  8. Development of the Biopen: a handheld device for surgical printing of adipose stem cells at a chondral wound site

    International Nuclear Information System (INIS)

    O’Connell, Cathal D; Thompson, Fletcher; Beirne, Stephen; Cornock, Rhys; Richards, Christopher J; Chung, Johnson; Gambhir, Sanjeev; Yue, Zhilian; Zhang, Binbin; Taylor, Adam; Quigley, Anita; Kapsa, Robert; Wallace, Gordon G; Di Bella, Claudia; Choong, Peter; Augustine, Cheryl; Bourke, Justin

    2016-01-01

    We present a new approach which aims to translate freeform biofabrication into the surgical field, while staying true to the practical constraints of the operating theatre. Herein we describe the development of a handheld biofabrication tool, dubbed the ‘biopen’, which enables the deposition of living cells and biomaterials in a manual, direct-write fashion. A gelatin–methacrylamide/hyaluronic acid–methacrylate (GelMa/HAMa) hydrogel was printed and UV crosslinked during the deposition process to generate surgically sculpted 3D structures. Custom titanium nozzles were fabricated to allow printing of multiple ink formulations in a collinear (side-by-side) geometry. Independently applied extrusion pressure for both chambers allows for geometric control of the printed structure and for the creation of compositional gradients. In vitro experiments demonstrated that human adipose stem cells maintain high viability (>97%) one week after biopen printing in GelMa/HAMa hydrogels. The biopen described in this study paves the way for the use of 3D bioprinting during the surgical process. The ability to directly control the deposition of regenerative scaffolds with or without the presence of live cells during the surgical process presents an exciting advance not only in the fields of cartilage and bone regeneration but also in other fields where tissue regeneration and replacement are critical. (paper)

  9. Through-container, extremely low concentration detection of multiple chemical markers of counterfeit alcohol using a handheld SORS device.

    Science.gov (United States)

    Ellis, David I; Eccles, Rebecca; Xu, Yun; Griffen, Julia; Muhamadali, Howbeer; Matousek, Pavel; Goodall, Ian; Goodacre, Royston

    2017-09-21

    Major food adulteration incidents occur with alarming frequency and are episodic, with the latest incident, involving the adulteration of meat from 21 producers in Brazil supplied to 60 other countries, reinforcing this view. Food fraud and counterfeiting involves all types of foods, feed, beverages, and packaging, with the potential for serious health, as well as significant economic and social impacts. In the spirit drinks sector, counterfeiters often 'recycle' used genuine packaging, or employ good quality simulants. To prove that suspect products are non-authentic ideally requires accurate, sensitive, analysis of the complex chemical composition while still in its packaging. This has yet to be achieved. Here, we have developed handheld spatially offset Raman spectroscopy (SORS) for the first time in a food or beverage product, and demonstrate the potential for rapid in situ through-container analysis; achieving unequivocal detection of multiple chemical markers known for their use in the adulteration and counterfeiting of Scotch whisky, and other spirit drinks. We demonstrate that it is possible to detect a total of 10 denaturants/additives in extremely low concentrations without any contact with the sample; discriminate between and within multiple well-known Scotch whisky brands, and detect methanol concentrations well below the maximum human tolerable level.

  10. Handheld Universal Diagnostic Sensor

    Science.gov (United States)

    Chan, Eugene

    2012-01-01

    The rHEALTH technology is designed to shrink an entire hospital testing laboratory onto a handheld device. A physician or healthcare provider performs the test by collecting a fingerstick of blood from a patient. The tiny volume of blood is inserted into the rHEALTH device. Inside the device is a microfluidic chip that contains small channels about the width of a human hair. These channels help move the blood and analyze the blood sample. The rHEALTH sensor uses proprietary reagents called nanostrips, which are nanoscale test strips that enable the clinical assays. The readout is performed by laser-induced fluorescence. Overall, the time from blood collection through analysis is less than a minute.

  11. Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices.

    Science.gov (United States)

    Mair, B; Drillich, M; Klein-Jöbstl, D; Kanz, P; Borchardt, S; Meyer, L; Schwendenwein, I; Iwersen, M

    2016-02-24

    Dairy cows have a massive demand for glucose at the onset of lactation. A poor adaption to this period leads to an excessive negative energy balance with an increased risk for ketosis and impaired animal health and production. Besides the measurement of ketones, analysing the glucose concentration in blood is reported as helpful instrument for diagnosis and differentiation of ketosis. Monitoring metabolic parameters requires multiple blood sampling. In other species, new blood sampling techniques have been introduced in which small amounts of blood are rapidly analysed using electronic hand-held devices. The objective of this study was to evaluate the suitability of capillary blood for blood glucose measurement in dairy cows using the hand-held devices FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini) and the WellionVet GLUCO CALEA, (WGC, MED TRUST). In total, 240 capillary blood samples were obtained from dry and fresh lactating Holstein-Friesian cows. Blood was collected from the skin of the exterior vulva by using a lancet. For method comparison, additional blood samples were taken from a coccygeal vessel and analyzed in a laboratory. Glucose concentrations measured by a standard laboratory method were defined as the criterion standard. The Pearson correlation coefficients between the glucose concentrations analyzed in capillary blood with the devices and the reference were 73% for the FSP, 81% for the GLX and 41% for the WGC. Bland-Altman plots showed biases of -18.8 mg/dL for the FSP, -11.2 mg/dL for the GLX and +20.82 mg/dL for the WGC. The optimized threshold determined by a Receiver Operating Characteristics analysis to detect hyperglycemia using the FSP was 43 mg/dL with a sensitivity (Se) and specificity (Sp) of 76 and 80%. Using the GLX and WGC optimized thresholds were 49 mg/dL (Se = 92%, Sp = 85%) and 95 mg/dL (Se = 39%, Sp = 92%). The results of this study demonstrate good performance characteristics for the GLX

  12. An efficient HW and SW design of H.264 video compression, storage and playback on FPGA devices for handheld thermal imaging systems

    Science.gov (United States)

    Gunay, Omer; Ozsarac, Ismail; Kamisli, Fatih

    2017-05-01

    Video recording is an essential property of new generation military imaging systems. Playback of the stored video on the same device is also desirable as it provides several operational benefits to end users. Two very important constraints for many military imaging systems, especially for hand-held devices and thermal weapon sights, are power consumption and size. To meet these constraints, it is essential to perform most of the processing applied to the video signal, such as preprocessing, compression, storing, decoding, playback and other system functions on a single programmable chip, such as FPGA, DSP, GPU or ASIC. In this work, H.264/AVC (Advanced Video Coding) compatible video compression, storage, decoding and playback blocks are efficiently designed and implemented on FPGA platforms using FPGA fabric and Altera NIOS II soft processor. Many subblocks that are used in video encoding are also used during video decoding in order to save FPGA resources and power. Computationally complex blocks are designed using FPGA fabric, while blocks such as SD card write/read, H.264 syntax decoding and CAVLC decoding are done using NIOS processor to benefit from software flexibility. In addition, to keep power consumption low, the system was designed to require limited external memory access. The design was tested using 640x480 25 fps thermal camera on CYCLONE V FPGA, which is the ALTERA's lowest power FPGA family, and consumes lower than 40% of CYCLONE V 5CEFA7 FPGA resources on average.

  13. Hand-held medical robots.

    Science.gov (United States)

    Payne, Christopher J; Yang, Guang-Zhong

    2014-08-01

    Medical robots have evolved from autonomous systems to tele-operated platforms and mechanically-grounded, cooperatively-controlled robots. Whilst these approaches have seen both commercial and clinical success, uptake of these robots remains moderate because of their high cost, large physical footprint and long setup times. More recently, researchers have moved toward developing hand-held robots that are completely ungrounded and manipulated by surgeons in free space, in a similar manner to how conventional instruments are handled. These devices provide specific functions that assist the surgeon in accomplishing tasks that are otherwise challenging with manual manipulation. Hand-held robots have the advantages of being compact and easily integrated into the normal surgical workflow since there is typically little or no setup time. Hand-held devices can also have a significantly reduced cost to healthcare providers as they do not necessitate the complex, multi degree-of-freedom linkages that grounded robots require. However, the development of such devices is faced with many technical challenges, including miniaturization, cost and sterility, control stability, inertial and gravity compensation and robust instrument tracking. This review presents the emerging technical trends in hand-held medical robots and future development opportunities for promoting their wider clinical uptake.

  14. Hand-held electronic data collection and procedure environment

    International Nuclear Information System (INIS)

    Kennedy, E.; Doniz, K.

    1996-01-01

    As part of a CANDU Owners Group project, AECL has developed a hand-held electronic data collection and procedure environment. Integral to this environment is the C omputerized Procedure Engine . The development of the CPE allows operators, maintainers, and technical support staff to execute virtually any type of station procedure on a general-purpose PC-compatible hand-held computer. There are several advantages to using the computerized procedures: less paper use and handling, reduction in human error, reduction in rework in the field, an increase in procedural compliance, and immediate availability of data to download to databases and plant information systems. The paper describes: the advantages of using computerized procedures, why early forms of computerized procedures were inadequate, the features that the C omputerized Procedure Engine o ffers to the user, the streamlined life cycle of a computerized procedure, and field experience. The paper concludes that computerized procedures are ready for pilot applications at stations. (author)

  15. 75 FR 36678 - In the Matter of Certain Authentication Systems, Including Software and Handheld Electronic...

    Science.gov (United States)

    2010-06-28

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-697] In the Matter of Certain Authentication Systems, Including Software and Handheld Electronic Devices; Notice of Commission Decision Not to... importation of certain authentication systems, including software and handheld electronic devices, by reason...

  16. 75 FR 8400 - In the Matter of Certain Wireless Communications System Server Software, Wireless Handheld...

    Science.gov (United States)

    2010-02-24

    ... Communications System Server Software, Wireless Handheld Devices and Battery Packs; Notice of Investigation... within the United States after importation of certain wireless communications system server software... certain wireless communications system server software, wireless handheld devices or battery packs that...

  17. Assessment of Laparoscopic Skills Performance: 2D Versus 3D Vision and Classic Instrument Versus New Hand-Held Robotic Device for Laparoscopy.

    Science.gov (United States)

    Leite, Mariana; Carvalho, Ana F; Costa, Patrício; Pereira, Ricardo; Moreira, Antonio; Rodrigues, Nuno; Laureano, Sara; Correia-Pinto, Jorge; Vilaça, João L; Leão, Pedro

    2016-02-01

    Laparoscopic surgery has undeniable advantages, such as reduced postoperative pain, smaller incisions, and faster recovery. However, to improve surgeons' performance, ergonomic adaptations of the laparoscopic instruments and introduction of robotic technology are needed. The aim of this study was to ascertain the influence of a new hand-held robotic device for laparoscopy (HHRDL) and 3D vision on laparoscopic skills performance of 2 different groups, naïve and expert. Each participant performed 3 laparoscopic tasks-Peg transfer, Wire chaser, Knot-in 4 different ways. With random sequencing we assigned the execution order of the tasks based on the first type of visualization and laparoscopic instrument. Time to complete each laparoscopic task was recorded and analyzed with one-way analysis of variance. Eleven experts and 15 naïve participants were included. Three-dimensional video helps the naïve group to get better performance in Peg transfer, Wire chaser 2 hands, and Knot; the new device improved the execution of all laparoscopic tasks (P < .05). For expert group, the 3D video system benefited them in Peg transfer and Wire chaser 1 hand, and the robotic device in Peg transfer, Wire chaser 1 hand, and Wire chaser 2 hands (P < .05). The HHRDL helps the execution of difficult laparoscopic tasks, such as Knot, in the naïve group. Three-dimensional vision makes the laparoscopic performance of the participants without laparoscopic experience easier, unlike those with experience in laparoscopic procedures. © The Author(s) 2015.

  18. Context-Aware Middleware Support for the Nomadic Mobile Services on Multi-homed Handheld Mobile Devices

    NARCIS (Netherlands)

    Pawar, Pravin; van Beijnum, Bert-Jan; Peddemors, Arjan; van Halteren, Aart

    2007-01-01

    Nowadays, a variety ofhandheld mobile devices are capable of connecting to the Internet using multiple network interfaces. This is referred to as multi-homing. In addition to this, enriched computation resources allow them to host nomadic mobile services and provide these services to the clients

  19. Evaluation of a hand-held far-ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens

    Directory of Open Access Journals (Sweden)

    Nerandzic Michelle M

    2012-05-01

    Full Text Available Abstract Background Environmental surfaces play an important role in transmission of healthcare-associated pathogens. There is a need for new disinfection methods that are effective against Clostridium difficile spores, but also safe and rapid. The Sterilray™ Disinfection Wand device is a hand-held room decontamination technology that utilizes far-ultraviolet radiation (185-230 nm to kill pathogens. Methods We examined the efficacy of disinfection using the Sterilray device in the laboratory, in rooms of hospitalized patients, and on surfaces outside of patient rooms (i.e. keyboards and portable medical equipment. Cultures for C. difficile, methicillin-resistant Staphylococcus aureus (MRSA, and vancomycin-resistant Enterococcus (VRE were collected from commonly-touched surfaces before and after use of the Sterilray device. Results On inoculated surfaces in the laboratory, application of the Sterilray device at a radiant dose of 100 mJ/cm2 for ~ 5 seconds consistently reduced recovery of C. difficile spores by 4.4 CFU log10, MRSA by 5.4 log10CFU and of VRE by 6.9 log10CFU. A >3 log10 reduction of MRSA and VRE was achieved in ~2 seconds at a lower radiant dose, but killing of C. difficile spores was significantly reduced. On keyboards and portable medical equipment that were inoculated with C. difficile spores, application of the Sterilray device at a radiant dose of 100���mJ/cm2 for ~ 5 seconds reduced contamination by 3.2 log10CFU. However, the presence of organic material reduced the lethal effect of the far-UV radiation. In hospital rooms that were not pre-cleaned, disinfection with the Sterilray device significantly reduced the frequency of positive C. difficile and MRSA cultures (P =0.007. Conclusions The Sterilray™ Disinfection Wand is a novel environmental disinfection technology that rapidly kills C. difficile spores and other healthcare-associated pathogens on surfaces. However, the presence of organic matter

  20. Handheld Device Adapted to Smartphone Cameras for the Measurement of Sodium Ion Concentrations at Saliva-Relevant Levels via Fluorescence

    OpenAIRE

    Lipowicz, Michelle; Garcia, Antonio

    2015-01-01

    The use of saliva sampling as a minimally-invasive means for drug testing and monitoring physiology is a subject of great interest to researchers and clinicians. This study describes a new optical method based on non-axially symmetric focusing of light using an oblate spheroid sample chamber. The device is simple, lightweight, low cost and is easily attached to several different brands/models of smartphones (Apple, Samsung, HTC and Nokia) for the measurement of sodium ion levels at physiologi...

  1. iPads, droids, and bugs: Infection prevention for mobile handheld devices at the point of care.

    Science.gov (United States)

    Manning, Mary Lou; Davis, James; Sparnon, Erin; Ballard, Raylene M

    2013-11-01

    Health care providers are increasingly using wireless media tablets, such as the Apple iPad, especially in the hospital setting. In the absence of specific tablet disinfection guidelines the authors applied what is known about the contamination of other nonmedical mobile communication devices to create a "common sense" bundle to guide wireless media tablet infection prevention practices. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  2. Feasibility of using a handheld electronic device for the collection of patient reported outcomes data from children

    OpenAIRE

    Vinney, Lisa A.; Grade, John; Connor, Nadine P.

    2011-01-01

    The manner in which a communication disorder affects health-related quality of life (QOL) in children is not known. Unfortunately, collection of quality of life data via traditional paper measures is labor intensive and has several other limitations, which hinder the investigation of pediatric quality of life in children. Currently, there is not sufficient research regarding the use of electronic devices to collect pediatric patient reported outcomes in order to address such limitations. Thus...

  3. Handheld Device Adapted to Smartphone Cameras for the Measurement of Sodium Ion Concentrations at Saliva-Relevant Levels via Fluorescence

    Directory of Open Access Journals (Sweden)

    Michelle Lipowicz

    2015-06-01

    Full Text Available The use of saliva sampling as a minimally-invasive means for drug testing and monitoring physiology is a subject of great interest to researchers and clinicians. This study describes a new optical method based on non-axially symmetric focusing of light using an oblate spheroid sample chamber. The device is simple, lightweight, low cost and is easily attached to several different brands/models of smartphones (Apple, Samsung, HTC and Nokia for the measurement of sodium ion levels at physiologically-relevant saliva concentrations. The sample and fluorescent reagent solutions are placed in a specially-designed, lightweight device that excludes ambient light and concentrates 470-nm excitation light, from a low-power photodiode, within the sample through non-axially-symmetric refraction. The study found that smartphone cameras and post-image processing quantitated sodium ion concentration in water over the range of 0.5–10 mM, yielding best-fit regressions of the data that agree well with a data regression of microplate luminometer results. The data suggest that fluorescence can be used for the measurement of salivary sodium ion concentrations in low-resource or point-of-care settings. With further fluorescent assay testing, the device may find application in a variety of enzymatic or chemical assays.

  4. The Rubble Rescue Radar (RRR): A low power hand-held microwave device for the detection of trapped human personnel

    International Nuclear Information System (INIS)

    Haddad, W.S.

    1997-01-01

    Each year, innocent human lives are lost in collapsed structures as a result of both natural and man-made disasters. We have developed a prototype device, called the Rubble Rescue Radar (RRR) as a aid to workers trying to locate trapped victims in urban search and rescue operations. The RRR is a motion sensor incorporating Micropower Impulse Radar and is capable of detecting human breathing motions through reinforced concrete. It is lightweight, and designed to be handled by a single operator for local searches in areas where trapped victims are expected. Tests of the first prototype device were conducted on site at LLNL using a mock rubble pile consisting of a reinforced concrete pipe with two concrete floor slabs placed against one side, and random concrete and asphalt debris piled against the other. This arrangement provides safe and easy access for instruments and/or human subjects. Breathing signals of a human subject were recorded with the RRR through one floor slab plus the wall of the pipe, two slabs plus the wall of the pipe, and the random rubble plus the wall of the pipe. Breathing and heart beat signals were also recorded of a seated human subject at a distance of 1 meter with no obstructions. Results and photographs of the experimental work are presented, and a design concept for the next generation device is described

  5. A feasibility and efficacy trial of a hand-held humidification device in patients undergoing radiotherapy for head and neck cancer.

    Science.gov (United States)

    Ghosh, Priyanka; Lazar, Ann A; Ryan, William R; Yom, Sue S

    2017-08-01

    This study aimed to evaluate the effects of warm-mist humidification during and after head and neck radiation therapy (HN RT) on quality of life (QOL), as measured by the M. D. Anderson Symptom Inventory-Head and Neck (MDASI-HN) HN score. A secondary aim was to compare QOL among compliers (≥60% of protocol-recommended usage) versus non-compliers. Twenty patients self-administered a hand-held, self-sterilizing humidification device for a recommended time of at least 15 min twice daily for 12 weeks. Patients completed the MDASI-HN instrument at RT start, after 6 weeks, and after 12 weeks. Compliance was reported weekly. The average HN score at baseline was 1.7 (SD = 1.8) and increased to 6.0 (SD = 1.6) after 6 weeks; this increase was much higher than anticipated and the primary endpoint could not be reached. However, compliers had an average of nearly two less HN symptoms (-1.8, 95% CI -4 to 0.2; p = 0.08) than non-compliers at 6 weeks and fewer symptoms at 12 weeks as well (-0.9, 95% CI -2.9 to 1.2; p = 0.39). The most common terms patients used to describe humidification were "helpful" and "soothing." Compliance with humidification during RT was associated with fewer reported HN symptoms and a strong trend to better QOL. Improvements were seen from compliance with occasional required use of a portable, inexpensive device. Our findings support continued efforts to reduce barriers to humidification, as an intervention that should be considered for standard HN RT clinical practice.

  6. Handheld multi-channel LAPS device as a transducer platform for possible biological and chemical multi-sensor applications

    International Nuclear Information System (INIS)

    Wagner, Torsten; Molina, Roberto; Yoshinobu, Tatsuo; Kloock, Joachim P.; Biselli, Manfred; Canzoneri, Michelangelo; Schnitzler, Thomas; Schoening, Michael J.

    2007-01-01

    The light-addressable potentiometric sensor is a promising technology platform for multi-sensor applications and lab-on-chip devices. However, many prior LAPS developments suffer from their lack in terms of non-portability, insufficient robustness, complicate handling, etc. Hence, portable and robust LAPS-based measurement devices have been investigated by the authors recently. In this work, a 'chip card'-based light-addressable potentiometric sensor system is presented. The utilisation of ordinary 'chip cards' allows an easy handling of different sensor chips for a wide range of possible applications. The integration of the electronic and the mechanical set-up into a single reader unit results in a compact design with the benefits of portability and low required space. In addition, the presented work includes a new multi-frequency measurement procedure, based on an FFT algorithm, which enables the simultaneous real-time measurement of up to 16 sensor spots. The comparison between the former batch-LAPS and the new FFT-based LAPS set-up will be presented. The immobilisation of biological cells (CHO: Chinese hamster ovary) demonstrates the possibility to record their metabolic activity with 16 measurement spots on the same chip. Furthermore, a Cd 2+ -selective chalcogenide-glass layer together with a pH-sensitive Ta 2 O 5 layer validates the use of the LAPS for chemical multi-sensor applications

  7. Studies on hand-held visual communication device for the deaf and speech-impaired I. Visual display window size.

    Science.gov (United States)

    Thurlow, W R

    1980-01-01

    Messages were presented which moved from right to left along an electronic alphabetic display which was varied in "window" size from 4 through 32 letter spaces. Deaf subjects signed the messages they perceived. Relatively few errors were made even at the highest rate of presentation, which corresponded to a typing rate of 60 words/min. It is concluded that many deaf persons can make effective use of a small visual display. A reduced cost is then possible for visual communication instruments for these people through reduced display size. Deaf subjects who can profit from a small display can be located by a sentence test administered by tape recorder which drives the display of the communication device by means of the standard code of the deaf teletype network.

  8. Studies on hand-held visual communication device for the deaf and speech-impaired 2. Keyboard design.

    Science.gov (United States)

    Thurlow, W R

    1980-01-01

    Experiments with keyboard arrangements of letters show that simple alphabetic letter-key sequences with 4 to 5 letters in a row lead to most rapid visual search performance. Such arrangements can be used on keyboards operated by the index finger of one hand. Arrangement of letters in words offers a promising alternative because these arrangements can be readily memorized and can result in small interletter distances on the keyboard for frequently occurring letter sequences. Experiments on operation of keyboards show that a space or shift key operated by the left hand (which also holds the communication device) results in faster keyboard operation than when space or shift keys on the front of the keyboard (operated by right hand) are used. Special problems of the deaf-blind are discussed. Keyboard arrangements are investigated, and matching tactual codes are suggested.

  9. Utility of mobile devices in the computerized tomography evaluation of intracranial hemorrhage

    International Nuclear Information System (INIS)

    Panughpath, Sridhar G; Kumar, Savith; Kalyanpur, Arjun

    2013-01-01

    To evaluate the utility of a mobile device to detect and assess intracranial hemorrhage (ICH) on head computed tomographys (CT) performed in the emergency setting. 100 head CT scans were randomly selected from our emergency radiology database and anonymized for patient demographics and clinical history. The studies were independently interpreted by two experienced radiologists in a blinded manner, initially on a mobile device (iPad, Apple computers) and subsequently, at an interval of one week, on a regular desktop workstation. Evaluation was directed towards detection, localization and characterization of hemorrhage. The results were assessed for accuracy, sensitivity, specificity and positive predictive value. Statistical significance was ascertained using Fisher's exact test. 27 of the examinations were positive for ICH, of which 11 had multiple hemorrhages. Of these there were 17 subdural, 18 intraparenchymal, 8 subarachnoid, 4 intraventricular and 2 extradural hemorrhages. In 96 of the studies there was complete concurrence between the iPad and desktop interpretations for both radiologists. Of 49 hemorrhages, 48 were accurately detected on the iPad by one of the radiologists. In the remaining case, a tiny intraventricular hemorrhage was missed by both radiologists on the iPad as well as on the workstation, indicating that the miss was more likely related to the very small size of the hemorrhage than the viewer used. We conclude that in the emergency setting, a mobile device with appropriate web-based pictue archiving and communication system (PACS) is effective in the detection of intracranial hemorrhage present on head CT

  10. Utility of mobile devices in the computerized tomography evaluation of intracranial hemorrhage

    Directory of Open Access Journals (Sweden)

    Sridhar G Panughpath

    2013-01-01

    Full Text Available Aim: To evaluate the utility of a mobile device to detect and assess intracranial hemorrhage (ICH on head computed tomographys (CT performed in the emergency setting. Materials and Methods: 100 head CT scans were randomly selected from our emergency radiology database and anonymized for patient demographics and clinical history. The studies were independently interpreted by two experienced radiologists in a blinded manner, initially on a mobile device (iPad, Apple computers and subsequently, at an interval of one week, on a regular desktop workstation. Evaluation was directed towards detection, localization and characterization of hemorrhage. The results were assessed for accuracy, sensitivity, specificity and positive predictive value. Statistical significance was ascertained using Fisher′s exact test. Results: 27 of the examinations were positive for ICH, of which 11 had multiple hemorrhages. Of these there were 17 subdural, 18 intraparenchymal, 8 subarachnoid, 4 intraventricular and 2 extradural hemorrhages. In 96 of the studies there was complete concurrence between the iPad and desktop interpretations for both radiologists. Of 49 hemorrhages, 48 were accurately detected on the iPad by one of the radiologists. In the remaining case, a tiny intraventricular hemorrhage was missed by both radiologists on the iPad as well as on the workstation, indicating that the miss was more likely related to the very small size of the hemorrhage than the viewer used. Conclusion: We conclude that in the emergency setting, a mobile device with appropriate web-based pictue archiving and communication system (PACS is effective in the detection of intracranial hemorrhage present on head CT.

  11. Handheld Navigation Device and Patient-Specific Cutting Guides Result in Similar Coronal Alignment for Primary Total Knee Arthroplasty: a Retrospective Matched Cohort Study.

    Science.gov (United States)

    Steinhaus, Michael E; McLawhorn, Alexander S; Richardson, Shawn S; Maher, Patrick; Mayman, David J

    2016-10-01

    Proper alignment of total knee arthroplasty (TKA) is essential for TKA function and may reduce the risk of aseptic failure. Technologies that prevent malalignment may reduce the risk of revision surgery. The purpose of this study was to compare two competing TKA systems that purport improved alignment: patient-specific instrumentation (PSI), and a handheld portable navigation device (NAV). After IRB approval, 49 consecutive PSI TKAs (40 patients) were matched based on preoperative characteristics to 49 NAV TKAs (40 patients) performed by a single surgeon. A blinded observer measured alignment on digital radiographs. Operating room records were reviewed for procedure times. Two-tailed paired sample t tests and McNemar's test were used as appropriate. Alpha level was 0.05 for all tests. Preoperative cohort characteristics were not different. Mean postoperative long-leg mechanical alignment was within ±1° of neutral for both groups, although statistically different ( p  = 0.026). There were no other significant differences in coronal alignment. PSI exhibited significantly greater posterior tibial slope (4.4°) compared to NAV (2.7°) ( p  = 0.004); PSI resulted in significantly more outliers (>6°; p  = 0.004). Procedure time for unilateral TKAs was lower for PSI (74.4 min) compared to that for NAV (80.6 min; p  = 0.023). NAV and PSI technologies provided excellent coronal plane alignment. NAV was better for sagittal tibial slope, while PSI procedure times were shorter for unilateral TKA. The impact of these technologies on patient-reported outcomes and TKA survivorship is controversial and should be the focus of future research.

  12. Computerized cost estimation spreadsheet and cost data base for fusion devices

    International Nuclear Information System (INIS)

    Hamilton, W.R.; Rothe, K.E.

    1985-01-01

    An automated approach to performing and cataloging cost estimates has been developed at the Fusion Engineering Design Center (FEDC), wherein the cost estimate record is stored in the LOTUS 1-2-3 spreadsheet on an IBM personal computer. The cost estimation spreadsheet is based on the cost coefficient/cost algorithm approach and incorporates a detailed generic code of cost accounts for both tokamak and tandem mirror devices. Component design parameters (weight, surface area, etc.) and cost factors are input, and direct and indirect costs are calculated. The cost data base file derived from actual cost experience within the fusion community and refined to be compatible with the spreadsheet costing approach is a catalog of cost coefficients, algorithms, and component costs arranged into data modules corresponding to specific components and/or subsystems. Each data module contains engineering, equipment, and installation labor cost data for different configurations and types of the specific component or subsystem. This paper describes the assumptions, definitions, methodology, and architecture incorporated in the development of the cost estimation spreadsheet and cost data base, along with the type of input required and the output format

  13. Distance Estimation Using Handheld Devices

    Science.gov (United States)

    2013-06-01

    applications developed in HTML5) is browser dependent, unlike native programming languages (like Java) which are OS dependent. HTML5 introduces a number...means we need to implement the Gecko engine for Firefox , Trident for Internet Explorer, and Blink for Google browsers. The compass direction is

  14. A feasibility study to develop a diabetes prevention program for young adults with prediabetes by using digital platforms and a handheld device.

    Science.gov (United States)

    Cha, EunSeok; Kim, Kevin H; Umpierrez, Guillermo; Dawkins, Colleen R; Bello, Morenike K; Lerner, Hannah M; Narayan, K M Venkat; Dunbar, Sandra B

    2014-01-01

    The purpose of this pilot study was to examine the feasibility and preliminary efficacy of an age-specific diabetes prevention program in young adults with prediabetes. A one-group pretest-posttest design was used. The inclusion criteria were age 18 to 29 years and the presence of prediabetes (either impaired fasting glucose of 100-125 mg/dL [5.55-6.94 mmol/L] or A1C of 5.7%-6.4%). Fifteen participants were enrolled in the study. A technology-based lifestyle coaching program focused on diet and physical activity and incorporating a handheld device and digital platforms was developed and tested. Psychosocial factors (health literacy, illness perception, self-efficacy, therapeutic efficacy) based on social cognitive theory, changes in diet and physical activity, and cardiometabolic risk factors were assessed at baseline and week 12 after the intervention. A paired-samples t test was performed to examine changes between baseline and postintervention on each psychosocial and physical variable. Participants' (n = 13 completers) mean age was 24.4 ± 2.2 years, 23.1% were male, and 53.8% were African American. Overall, the participants were satisfied with the intervention (mean score, 4.15 on a 5-point, Likert-type scale). Between pre- and posttesting, mean body mass index and mean A1C decreased from 41.0 ± 7.3 kg/m(2) and 6.0 ± 0.5% to 40.1 ± 7.0 kg/m(2) and 5.6 ± 0.5%, respectively, whereas mean fasting glucose did not significantly change (from 92.6 ± 11 to 97.6 ± 14.3 mg/dL [5.14 ± 0.61 to 5.42 ± 0.79 mmol/L]). The intervention resulted in reduced A1C and a trend toward decreased body mass index in obese sedentary young adults with prediabetes after 12 weeks. Further study through a randomized clinical trial with a longer intervention period is warranted. © 2014 The Author(s).

  15. Desenvolvimento de software oftalmológico para computação móvel Development of ophthalmologic software for handheld devices

    Directory of Open Access Journals (Sweden)

    Gustavo Teixeira Grottone

    2006-08-01

    do grupo Ultrascan foi de 20,93D. Resultado semelhante à média do grupo programa em estudo. Os desvios-padrão das amostras também foram semelhantes (4,53D. CONCLUSÃO: A precisão do programa testado foi semelhante a do aparelho de ultra-sonografia ocular Ultrascan, para a fórmula SRK/T. O funcionamento do programa se demonstrou estável sem travamentos nos testes efetuados. A utilização deste programa em unidades cirúrgicas onde exista a necessidade de troca ou recálculo da lente intra-ocular do paciente, é alternativa segura, móvel e portátil, que pode auxiliar o cirurgião na escolha de uma nova lente.INTRODUCTION: The formulas for calculation of intraocular lenses have evolved since the first theoretical formulas by Fyodorov. Among the second generation formulas, the SRK-I formula has a simple calculation, taking into account a calculation that only involved anteroposterior length, IOL constant and average keratometry. With the evolution of those formulas, complexicity increased making the reconfiguration of parameters in special situations impracticable. In this way the production and development of software for such a purpose, can help surgeons to recalculate those values if needed. PURPOSE: To idealize, develop and test a Brazilian software for calculation of IOL dioptric power for handheld computers. METHODS: For the development and programming of software for calculation of IOL, we used PocketC program (OrbWorks Concentrated Software, USA. We compared the results collected from a gold-standard device (Ultrascan/Alcon Labs with the simulation of 100 fictitious patients, using the same IOL parameters. The results were grouped for ULTRASCAN data and SOFTWARE data. Using SRK/T formula the range of those parameters included a keratometry varying between 35 and 55D, axial length between 20 and 28 mm, IOL constants of 118.7, 118.3 and 115.8. RESULTS: Using Wilcoxon test, it was shown that the groups do not differ (p=0.314. We had a variation in the

  16. Handheld Computers in Education: An Industry Perspective

    Science.gov (United States)

    van 't Hooft, Mark; Vahey, Philip

    2007-01-01

    Five representatives from the mobile computing industry provide their perspectives on handhelds in education. While some of their ideas differ, they all agree on the importance of staff development, appropriate curriculum development, and teacher support to create the kinds of personalized learning environments that mobile devices make possible.

  17. Doctors' experience with handheld computers in clinical practice: qualitative study.

    Science.gov (United States)

    McAlearney, Ann Scheck; Schweikhart, Sharon B; Medow, Mitchell A

    2004-05-15

    To examine doctors' perspectives about their experiences with handheld computers in clinical practice. Qualitative study of eight focus groups consisting of doctors with diverse training and practice patterns. Six practice settings across the United States and two additional focus group sessions held at a national meeting of general internists. 54 doctors who did or did not use handheld computers. Doctors who used handheld computers in clinical practice seemed generally satisfied with them and reported diverse patterns of use. Users perceived that the devices helped them increase productivity and improve patient care. Barriers to use concerned the device itself and personal and perceptual constraints, with perceptual factors such as comfort with technology, preference for paper, and the impression that the devices are not easy to use somewhat difficult to overcome. Participants suggested that organisations can help promote handheld computers by providing advice on purchase, usage, training, and user support. Participants expressed concern about reliability and security of the device but were particularly concerned about dependency on the device and over-reliance as a substitute for clinical thinking. Doctors expect handheld computers to become more useful, and most seem interested in leveraging (getting the most value from) their use. Key opportunities with handheld computers included their use as a stepping stone to build doctors' comfort with other information technology and ehealth initiatives and providing point of care support that helps improve patient care.

  18. Highly resolving computerized tomography

    International Nuclear Information System (INIS)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions. (BWU) [de

  19. Highly resolving computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, B.; Petersen, D.; Walter, E.

    1984-01-01

    With the development of highly-resolving devices for computerized tomography, CT diagnosis of the lumbar vertebral column has gained increasing importance. As an ambulatory, non-invasive method it has proved in comparative studies to be at least equivalent to myelography in the detection of dislocations of inter-vertebral disks (4,6,7,15). Because with modern devices not alone the bones, but especially the spinal soft part structures are clearly and precisely presented with a resolution of distinctly below 1 mm, a further improvement of the results is expected as experience will increase. The authors report on the diagnosis of the lumbar vertebral column with the aid of a modern device for computerized tomography and wish to draw particular attention to the possibility of doing this investigation as a routine, and to the diagnostic value of secondary reconstructions.

  20. Correcting for motion artifact in handheld laser speckle images

    Science.gov (United States)

    Lertsakdadet, Ben; Yang, Bruce Y.; Dunn, Cody E.; Ponticorvo, Adrien; Crouzet, Christian; Bernal, Nicole; Durkin, Anthony J.; Choi, Bernard

    2018-03-01

    Laser speckle imaging (LSI) is a wide-field optical technique that enables superficial blood flow quantification. LSI is normally performed in a mounted configuration to decrease the likelihood of motion artifact. However, mounted LSI systems are cumbersome and difficult to transport quickly in a clinical setting for which portability is essential in providing bedside patient care. To address this issue, we created a handheld LSI device using scientific grade components. To account for motion artifact of the LSI device used in a handheld setup, we incorporated a fiducial marker (FM) into our imaging protocol and determined the difference between highest and lowest speckle contrast values for the FM within each data set (Kbest and Kworst). The difference between Kbest and Kworst in mounted and handheld setups was 8% and 52%, respectively, thereby reinforcing the need for motion artifact quantification. When using a threshold FM speckle contrast value (KFM) to identify a subset of images with an acceptable level of motion artifact, mounted and handheld LSI measurements of speckle contrast of a flow region (KFLOW) in in vitro flow phantom experiments differed by 8%. Without the use of the FM, mounted and handheld KFLOW values differed by 20%. To further validate our handheld LSI device, we compared mounted and handheld data from an in vivo porcine burn model of superficial and full thickness burns. The speckle contrast within the burn region (KBURN) of the mounted and handheld LSI data differed by burns. Collectively, our results suggest the potential of handheld LSI with an FM as a suitable alternative to mounted LSI, especially in challenging clinical settings with space limitations such as the intensive care unit.

  1. Effect of the angle of apical resection on apical leakage, measured with a computerized fluid filtration device.

    Science.gov (United States)

    Garip, Hasan; Garip, Yıldız; Oruçoğlu, Hasan; Hatipoğlu, Seda

    2011-03-01

    We determined the effect of the angle of apical resection on apical leakage using a computerized fluid filtration meter with a laser system and a digital air pressure regulator in 46 extracted single-rooted human teeth. Orthograde endodontic treatment was performed. The root canals were prepared up to a size 50 K-type file with 17% EDTA solution (Roth International, Chicago, IL) and 5% NaOCl solution as the irrigant. Gates Glidden burs (Maillefer Instruments, Ballaigues, Switzerland) were used to flare the coronal two thirds of the canal. All canals were dried with paper points and then obturated using cold lateral condensation (except for the positive controls) of gutta-percha points and AH plus (Dentsply DeTrey, Konstanz, Germany). All 40 roots were sectioned 3 mm from the apex. Forty teeth were assigned randomly into 1 of 4 experimental groups of 10 teeth each: in group 1, the teeth were resected apically (90° angle) and the cavities were obturated with mineral trioxide aggregate (MTA); in group 2, after apical resection (90° angle), a root-end cavity was prepared using ultrasonic diamond retrotips and the cavities were obturated with MTA; in group 3, the teeth were resected apically (∼45° angle) and the cavities were obturated with MTA; and in group 4, after apical resection (∼45° angle), a root-end cavity was prepared using ultrasonic diamond retrotips and the cavities were obturated with MTA. An additional 6 teeth were used as controls (3 each, negative and positive controls). Apical leakage was measured using a computerized fluid filtration meter with a laser system. The mean apical microleakage was 2.0 ± 0.4 × 10(-4), 1.6 ± 0.6 × 10(-4), 1.6 ± 0.9 × 10(-4), and 1.8 ± 0.7 × 10(-4) μL/cmH(2)O/min(-1) at 1.2 atm, in groups 1 to 4, respectively. Although the mean apical microleakage was greater in group 1, the differences among the 4 groups were not statistically significant (P > .05). The results of these in vitro studies showed that when an

  2. My-Mini-Pet: A Handheld Pet-Nurturing Game to Engage Students in Arithmetic Practices

    Science.gov (United States)

    Liao, C. C. Y.; Chen, Z-H.; Cheng, H. N. H.; Chen, F-C.; Chan, T-W.

    2011-01-01

    In the last decade, more and more games have been developed for handheld devices. Furthermore, the popularity of handheld devices and increase of wireless computing can be taken advantage of to provide students with more learning opportunities. Games also could bring promising benefits--specifically, motivating students to learn/play, sustaining…

  3. UV-C decontamination of hand-held tablet devices in the healthcare environment using the Codonics D6000™ disinfection system.

    Science.gov (United States)

    Muzslay, M; Yui, S; Ali, S; Wilson, A P R

    2018-04-09

    Mobile phones and tablet computers may be contaminated with microorganisms and become a potential reservoir for cross-transmission of pathogens between healthcare workers and patients. There is no generally accepted guidance how to reduce contamination on mobile devices in healthcare settings. Our aim was to determine the efficacy of the Codonics D6000™ UV-C disinfection device. Daily disinfection reduced contamination on screens and on protective cases (test) significantly, but not all cases (control) could be decontaminated. The median aerobic colony count on the control and the test cases was 52 (IQR 33-89) cfu/25cm 2 and 22 (IQR 10.5-41) cfu/25cm 2 respectively before disinfection. Copyright © 2018. Published by Elsevier Ltd.

  4. Computerized tomography

    International Nuclear Information System (INIS)

    1980-01-01

    Improvements in the design of computerized tomographic X-ray equipment are described which lead to improvements in the mechanical properties, speed and size of scanning areas. The method envisages the body being scanned as a two-dimensional matrix of elements arising from a plurality of concentric rings. The concentric centre need not coincide with the axis of rotation. The procedures for rotation of the X-ray beam and detectors around the patient and for translating the measured information into attenuation coefficients for each matrix element of the body are described in detail. Explicit derivations are given for the mathematical formulae used. (U.K.)

  5. Fentanyl Iontophoretic Transdermal System (IONSYS(®)) can be Safely used in the Hospital Environment with X-Rays, Computerized Tomography and Radiofrequency Identification Devices.

    Science.gov (United States)

    Lemke, John; Sardariani, Edmond; Phipps, Joseph Bradley; Patel, Niki; Itri, Loretta M; Caravelli, James; Viscusi, Eugene R

    2016-09-01

    Fentanyl iontophoretic transdermal system (fentanyl ITS, IONSYS(®)) is a patient-controlled analgesia system used for the management of acute postoperative pain, designed to be utilized in a hospital setting. The objective of the two studies was to determine if fentanyl ITS could be safely used with X-rays, computerized tomography (CT) scans and radiofrequency identification (RFID) devices. The ITS system has two components: controller and drug unit; the studies utilized ITS systems without fentanyl, referred to as the ITS Placebo system. The first study evaluated the effect of X-radiation on the operation of an ITS Placebo system. Five ITS Placebo systems were exposed to X-rays (20 and 200 mSv total radiation dose-the 200 mSv radiation dose represents a tenfold higher exposure than in clinical practice) while operating in the Ready Mode and five were exposed while operating in the Dose Mode. The second study evaluated the effect of RFID (worst-case scenario of direct contact with an RFID transmitter) on the operation of an ITS Placebo system. During these tests, observations of the user interface and measurements of output voltage confirmed proper function throughout all operational modes (Ready Mode, Dose Mode, End-of-Use Mode, and End-of-Life Mode). The ITS Placebo system met all specifications and no functional anomalies were observed during and following X-ray exposure at two radiation dose levels or exposure at six different combinations of RFID frequencies and field strengths. The performance of the ITS system was unaffected by X-ray exposure levels well beyond those associated with diagnostic X-rays and CT scans, and by exposure to radiofrequency field strengths typically generated by RFID devices. These results provide added confidence to clinicians that the fentanyl ITS system does not need to be removed during diagnostic X-rays and CT scans and can also be utilized in close proximity to RFID devices. The studies and writing of this manuscript were

  6. Technology-enabled division of labour: the use of handhelds

    NARCIS (Netherlands)

    Benders, J.G.J.M.; Schouteten, R.L.J.; Ruijsscher, C. de

    2012-01-01

    Using the task pool model and data from 15 establishments in the Dutch hospitality industry, this study shows how and why applying handhelds affects the division of labour. These devices allow to split the waiters' jobs into separate tasks which tend to be combined into two separate "sub jobs": the

  7. Technology-enabled division of labour : The use of handhelds

    NARCIS (Netherlands)

    Benders, J.G.J.M.; Schouteten, R.; de Ruijsscher, C.

    2012-01-01

    Using the task pool model and data from 15 establishments in the Dutch hospitality industry, this study shows how and why applying handhelds affects the division of labour. These devices allow to split the waiters' jobs into separate tasks which tend to be combined into two separate "sub jobs": the

  8. Pyxis handheld polarimetric imager

    Science.gov (United States)

    Chenault, David B.; Pezzaniti, J. Larry; Vaden, Justin P.

    2016-05-01

    The instrumentation for measuring infrared polarization signatures has seen significant advancement over the last decade. Previous work has shown the value of polarimetric imagery for a variety of target detection scenarios including detection of manmade targets in clutter and detection of ground and maritime targets while recent work has shown improvements in contrast for aircraft detection and biometric markers. These data collection activities have generally used laboratory or prototype systems with limitations on the allowable amount of target motion or the sensor platform and usually require an attached computer for data acquisition and processing. Still, performance and sensitivity have been steadily getting better while size, weight, and power requirements have been getting smaller enabling polarimetric imaging for a greater or real world applications. In this paper, we describe Pyxis®, a microbolometer based imaging polarimeter that produces live polarimetric video of conventional, polarimetric, and fused image products. A polarization microgrid array integrated in the optical system captures all polarization states simultaneously and makes the system immune to motion artifacts of either the sensor or the scene. The system is battery operated, rugged, and weighs about a quarter pound, and can be helmet mounted or handheld. On board processing of polarization and fused image products enable the operator to see polarimetric signatures in real time. Both analog and digital outputs are possible with sensor control available through a tablet interface. A top level description of Pyxis® is given followed by performance characteristics and representative data.

  9. 75 FR 43206 - In the Matter of Certain Wireless Communications System Server Software, Wireless Handheld...

    Science.gov (United States)

    2010-07-23

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-706] In the Matter of Certain Wireless Communications System Server Software, Wireless Handheld Devices and Battery Packs: Notice of Commission... United States after importation of certain wireless communications system server software, wireless...

  10. Use of mobile devices in the emergency department: A scoping review.

    Science.gov (United States)

    Dexheimer, Judith W; Borycki, Elizabeth M

    2015-12-01

    Electronic health records are increasingly used in regional health authorities, healthcare systems, hospitals, and clinics throughout North America. The emergency department provides care for urgent and critically ill patients. Over the past several years, emergency departments have become more computerized. Tablet computers and Smartphones are increasingly common in daily use. As part of the computerization trend, we have seen the introduction of handheld computers, tablets, and Smartphones into practice as a way of providing health professionals (e.g. physicians, nurses) with access to patient information and decision support in the emergency department. In this article, we present a scoping review and outline the current state of the research using mobile devices in the emergency departments. Our findings suggest that there is very little research evidence that supports the use of these mobile devices, and more research is needed to better understand and optimize the use of mobile devices. Given the prevalence of handheld devices, it is inevitable that more decision support, charting, and other activities will be performed on these devices. These developments have the potential to improve the quality and timeliness of care but should be thoroughly evaluated. © The Author(s) 2014.

  11. Computerizing primary schools in rural kenya

    DEFF Research Database (Denmark)

    Ogembo, J.G.; Ngugi, B.; Pelowski, Matthew John

    2012-01-01

    questions surrounding this endeavour. Specifically: 1.) what problems do rural schools actually want to solve with computerization; 2.) is computerization the most important priority for rural schools; 3.) are schools ready, in terms of infrastructure, for a computer in the classroom; or 4.) might...... and protective roofing -posing severe challenges to the outstanding conception of computerization. We consider these results and make recommendations for better adapting programs for computer introduction, and also suggest the use of new innovative devices, such as cell phones, which might already have overcome......This paper investigates the outstanding challenges facing primary schools' computerization in rural Kenya. Computerization of schools is often envisaged as a 'magic', or at least a particularly efficient, solution to many of the problems that developing countries face in improving primary school...

  12. Handheld microwave bomb-detecting imaging system

    Science.gov (United States)

    Gorwara, Ashok; Molchanov, Pavlo

    2017-05-01

    Proposed novel imaging technique will provide all weather high-resolution imaging and recognition capability for RF/Microwave signals with good penetration through highly scattered media: fog, snow, dust, smoke, even foliage, camouflage, walls and ground. Image resolution in proposed imaging system is not limited by diffraction and will be determined by processor and sampling frequency. Proposed imaging system can simultaneously cover wide field of view, detect multiple targets and can be multi-frequency, multi-function. Directional antennas in imaging system can be close positioned and installed in cell phone size handheld device, on small aircraft or distributed around protected border or object. Non-scanning monopulse system allows dramatically decrease in transmitting power and at the same time provides increased imaging range by integrating 2-3 orders more signals than regular scanning imaging systems.

  13. Evaluation of Handheld Scanners for Automotive Applications

    Directory of Open Access Journals (Sweden)

    Wadea Ameen

    2018-01-01

    Full Text Available The process of generating a computerized geometric model for an existing part is known as Reverse Engineering (RE. It is a very useful technique in product development and plays a significant role in automotive, aerospace, and medical industries. In fact, it has been getting remarkable attention in manufacturing industries owing to its advanced data acquisition technologies. The process of RE is based on two primary steps: data acquisition (also known as scanning and data processing. To facilitate point data acquisition, a variety of scanning systems is available with different capabilities and limitations. Although the optical control of 3D scanners is fully developed, still several factors can affect the quality of the scanned data. As a result, the proper selection of scanning parameters, such as resolution, laser power, shutter time, etc., becomes very crucial. This kind of investigation can be very helpful and provide its users with guidelines to identify the appropriate factors. Moreover, it is worth noting that no single system is ideal in all applications. Accordingly, this work has compared two portable (handheld systems based on laser scanning and white light optical scanning for automotive applications. A car door containing a free-form surface has been used to achieve the above-mentioned goal. The design of experiments has been employed to determine the effects of different scanning parameters and optimize them. The capabilities and limitations have been identified by comparing the two scanners in terms of accuracy, scanning time, triangle numbers, ease of use, and portability. Then, the relationships between the system capabilities and the application requirements have been established. The results revealed that the laser scanner performed better than the white light scanner in terms of accuracy, while the white light scanner performed better in terms of acquisition speed and triangle numbers.

  14. A novel fully integrated handheld gamma camera

    International Nuclear Information System (INIS)

    Massari, R.; Ucci, A.; Campisi, C.; Scopinaro, F.; Soluri, A.

    2016-01-01

    In this paper, we present an innovative, fully integrated handheld gamma camera, namely designed to gather in the same device the gamma ray detector with the display and the embedded computing system. The low power consumption allows the prototype to be battery operated. To be useful in radioguided surgery, an intraoperative gamma camera must be very easy to handle since it must be moved to find a suitable view. Consequently, we have developed the first prototype of a fully integrated, compact and lightweight gamma camera for radiopharmaceuticals fast imaging. The device can operate without cables across the sterile field, so it may be easily used in the operating theater for radioguided surgery. The prototype proposed consists of a Silicon Photomultiplier (SiPM) array coupled with a proprietary scintillation structure based on CsI(Tl) crystals. To read the SiPM output signals, we have developed a very low power readout electronics and a dedicated analog to digital conversion system. One of the most critical aspects we faced designing the prototype was the low power consumption, which is mandatory to develop a battery operated device. We have applied this detection device in the lymphoscintigraphy technique (sentinel lymph node mapping) comparing the results obtained with those of a commercial gamma camera (Philips SKYLight). The results obtained confirm a rapid response of the device and an adequate spatial resolution for the use in the scintigraphic imaging. This work confirms the feasibility of a small gamma camera with an integrated display. This device is designed for radioguided surgery and small organ imaging, but it could be easily combined into surgical navigation systems.

  15. A novel fully integrated handheld gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Massari, R.; Ucci, A.; Campisi, C. [Biostructure and Bioimaging Institute (IBB), National Research Council of Italy (CNR), Rome (Italy); Scopinaro, F. [University of Rome “La Sapienza”, S. Andrea Hospital, Rome (Italy); Soluri, A., E-mail: alessandro.soluri@ibb.cnr.it [Biostructure and Bioimaging Institute (IBB), National Research Council of Italy (CNR), Rome (Italy)

    2016-10-01

    In this paper, we present an innovative, fully integrated handheld gamma camera, namely designed to gather in the same device the gamma ray detector with the display and the embedded computing system. The low power consumption allows the prototype to be battery operated. To be useful in radioguided surgery, an intraoperative gamma camera must be very easy to handle since it must be moved to find a suitable view. Consequently, we have developed the first prototype of a fully integrated, compact and lightweight gamma camera for radiopharmaceuticals fast imaging. The device can operate without cables across the sterile field, so it may be easily used in the operating theater for radioguided surgery. The prototype proposed consists of a Silicon Photomultiplier (SiPM) array coupled with a proprietary scintillation structure based on CsI(Tl) crystals. To read the SiPM output signals, we have developed a very low power readout electronics and a dedicated analog to digital conversion system. One of the most critical aspects we faced designing the prototype was the low power consumption, which is mandatory to develop a battery operated device. We have applied this detection device in the lymphoscintigraphy technique (sentinel lymph node mapping) comparing the results obtained with those of a commercial gamma camera (Philips SKYLight). The results obtained confirm a rapid response of the device and an adequate spatial resolution for the use in the scintigraphic imaging. This work confirms the feasibility of a small gamma camera with an integrated display. This device is designed for radioguided surgery and small organ imaging, but it could be easily combined into surgical navigation systems.

  16. Texting while driving: is speech-based text entry less risky than handheld text entry?

    Science.gov (United States)

    He, J; Chaparro, A; Nguyen, B; Burge, R J; Crandall, J; Chaparro, B; Ni, R; Cao, S

    2014-11-01

    Research indicates that using a cell phone to talk or text while maneuvering a vehicle impairs driving performance. However, few published studies directly compare the distracting effects of texting using a hands-free (i.e., speech-based interface) versus handheld cell phone, which is an important issue for legislation, automotive interface design and driving safety training. This study compared the effect of speech-based versus handheld text entries on simulated driving performance by asking participants to perform a car following task while controlling the duration of a secondary text-entry task. Results showed that both speech-based and handheld text entries impaired driving performance relative to the drive-only condition by causing more variation in speed and lane position. Handheld text entry also increased the brake response time and increased variation in headway distance. Text entry using a speech-based cell phone was less detrimental to driving performance than handheld text entry. Nevertheless, the speech-based text entry task still significantly impaired driving compared to the drive-only condition. These results suggest that speech-based text entry disrupts driving, but reduces the level of performance interference compared to text entry with a handheld device. In addition, the difference in the distraction effect caused by speech-based and handheld text entry is not simply due to the difference in task duration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Handheld ESPI-speckle interferometer

    DEFF Research Database (Denmark)

    Skov Hansen, René

    2003-01-01

    . The interferometer presented here is a compact version of the set-up, Which is capable of measuring displacements of small objects, having either a specularly reflecting-or a diffusely scattering surface. The small optical set-up together with the use of the popular USB-communication for acquiring the images...... and controlling the phase of the reference wave constitutes a compact "handheld" instrument and eliminates the need for installing extra hardware, such as frame grabber and Digital to Analog converter, in the host computer....

  18. Accentuated Factors of Handheld Computing

    DEFF Research Database (Denmark)

    Andersson, Bo; Henningsson, Stefan

    The recent years of rapid development of mobile technologies creates opportunities for new user-groups in the mobile workforce to take advantage of in-formation systems (IS). However, to apprehend and harness these opportunities for mobile IS it is crucial to fully understand the user group and t......, these two steps develop the framework towards a theoretical contribution as theory for describing handheld computing from a designer’s perspective. Thirteen semi-structured interviews were made and the tentative framework was elaborated and confirmed....

  19. Wireless Handhelds to Support Clinical Nursing Practicum

    Science.gov (United States)

    Wu, Cheng-Chih; Lai, Chin-Yuan

    2009-01-01

    This paper reports our implementation and evaluation of a wireless handheld learning environment used to support a clinical nursing practicum course. The learning environment was designed so that nursing students could use handhelds for recording information, organizing ideas, assessing patients, and also for interaction and collaboration with…

  20. Using medical knowledge sources on handheld computers--a qualitative study among junior doctors.

    Science.gov (United States)

    Axelson, Christian; Wårdh, Inger; Strender, Lars-Erik; Nilsson, Gunnar

    2007-09-01

    The emergence of mobile computing could have an impact on how junior doctors learn. To exploit this opportunity it is essential to understand their information seeking process. To explore junior doctors' experiences of using medical knowledge sources on handheld computers. Interviews with five Swedish junior doctors. A qualitative manifest content analysis of a focus group interview followed by a qualitative latent content analysis of two individual interviews. A focus group interview showed that users were satisfied with access to handheld medical knowledge sources, but there was concern about contents, reliability and device dependency. Four categories emerged from individual interviews: (1) A feeling of uncertainty about using handheld technology in medical care; (2) A sense of security that handhelds can provide; (3) A need for contents to be personalized; (4) A degree of adaptability to make the handheld a versatile information tool. A theme was established to link the four categories together, as expressed in the Conclusion section. Junior doctors' experiences of using medical knowledge sources on handheld computers shed light on the need to decrease uncertainty about clinical decisions during medical internship, and to find ways to influence the level of self-confidence in the junior doctor's process of decision-making.

  1. Development and testing of a scale to assess physician attitudes about handheld computers with decision support.

    Science.gov (United States)

    Ray, Midge N; Houston, Thomas K; Yu, Feliciano B; Menachemi, Nir; Maisiak, Richard S; Allison, Jeroan J; Berner, Eta S

    2006-01-01

    The authors developed and evaluated a rating scale, the Attitudes toward Handheld Decision Support Software Scale (H-DSS), to assess physician attitudes about handheld decision support systems. The authors conducted a prospective assessment of psychometric characteristics of the H-DSS including reliability, validity, and responsiveness. Participants were 82 Internal Medicine residents. A higher score on each of the 14 five-point Likert scale items reflected a more positive attitude about handheld DSS. The H-DSS score is the mean across the fourteen items. Attitudes toward the use of the handheld DSS were assessed prior to and six months after receiving the handheld device. Cronbach's Alpha was used to assess internal consistency reliability. Pearson correlations were used to estimate and detect significant associations between scale scores and other measures (validity). Paired sample t-tests were used to test for changes in the mean attitude scale score (responsiveness) and for differences between groups. Internal consistency reliability for the scale was alpha = 0.73. In testing validity, moderate correlations were noted between the attitude scale scores and self-reported Personal Digital Assistant (PDA) usage in the hospital (correlation coefficient = 0.55) and clinic (0.48), p DSS scale was reliable, valid, and responsive. The scale can be used to guide future handheld DSS development and implementation.

  2. Prospective evaluation of an internet-linked handheld computer critical care knowledge access system.

    Science.gov (United States)

    Lapinsky, Stephen E; Wax, Randy; Showalter, Randy; Martinez-Motta, J Carlos; Hallett, David; Mehta, Sangeeta; Burry, Lisa; Stewart, Thomas E

    2004-12-01

    Critical care physicians may benefit from immediate access to medical reference material. We evaluated the feasibility and potential benefits of a handheld computer based knowledge access system linking a central academic intensive care unit (ICU) to multiple community-based ICUs. Four community hospital ICUs with 17 physicians participated in this prospective interventional study. Following training in the use of an internet-linked, updateable handheld computer knowledge access system, the physicians used the handheld devices in their clinical environment for a 12-month intervention period. Feasibility of the system was evaluated by tracking use of the handheld computer and by conducting surveys and focus group discussions. Before and after the intervention period, participants underwent simulated patient care scenarios designed to evaluate the information sources they accessed, as well as the speed and quality of their decision making. Participants generated admission orders during each scenario, which were scored by blinded evaluators. Ten physicians (59%) used the system regularly, predominantly for nonmedical applications (median 32.8/month, interquartile range [IQR] 28.3-126.8), with medical software accessed less often (median 9/month, IQR 3.7-13.7). Eight out of 13 physicians (62%) who completed the final scenarios chose to use the handheld computer for information access. The median time to access information on the handheld handheld computer was 19 s (IQR 15-40 s). This group exhibited a significant improvement in admission order score as compared with those who used other resources (P = 0.018). Benefits and barriers to use of this technology were identified. An updateable handheld computer system is feasible as a means of point-of-care access to medical reference material and may improve clinical decision making. However, during the study, acceptance of the system was variable. Improved training and new technology may overcome some of the barriers we

  3. Electronic prescribing: criteria for evaluating handheld prescribing systems and an evaluation of a new, handheld, wireless wide area network (WWAN) prescribing system.

    Science.gov (United States)

    Goldblum, O M

    2001-02-01

    The objectives of this study were: 1) to establish criteria for evaluating handheld computerized prescribing systems; and 2) to evaluate out-of-box performance and features of a new, Palm Operating System (OS)-based, handheld, wireless wide area network (WWAN) prescribing system. The system consisted of a Palm Vx handheld organizer, a Novatel Minstrel V wireless modem, OmniSky wireless internet access and ePhysician ePad 1.1, the Palm OS electronic prescribing software program. A dermatologist familiar with healthcare information technology conducted an evaluation of the performance and features of a new, handheld, WWAN electronic prescribing system in an office practice during a three-month period in 2000. System performance, defined as transmission success rate, was determined from data collected during the three-month trial. Evaluation criteria consisted of an analysis of features found in electronic prescribing systems. All prescriptions written for all patients seen during a three-month period (August - November, 2000) were eligible for inclusion. Prescriptions written for patients who intended to fill them at pharmacies without known facsimile receiving capabilities were excluded from the study. The performance of the system was evaluated using data collected during the study. Criteria for evaluating features of electronic prescribing systems were developed and used to analyze the system employed in this study. During this three-month trial, 200 electronic prescriptions were generated for 132 patients included in the study. Of these prescriptions, 92.5 percent were successfully transmitted to pharmacies. Transmission failures resulted from incorrect facsimile numbers and non-functioning facsimile machines. Criteria established for evaluation of electronic prescribing systems included System (Hardware & Software), Costs, System Features, Printing & Transmission, Formulary & Insurance, Customization, Drug Safety and Security. This study is the first effort to

  4. The Effects of Computerized Auditory Feedback on Electronic Article Surveillance Tag Placement in an Auto-Parts Distribution Center

    Science.gov (United States)

    Goomas, David T.

    2008-01-01

    In this report from the field, computerized auditory feedback was used to inform order selectors and order selector auditors in a distribution center to add an electronic article surveillance (EAS) adhesive tag. This was done by programming handheld computers to emit a loud beep for high-priced items upon scanning the item's bar-coded Universal…

  5. Position statement on use of hand-held portable dental X-ray equipment

    International Nuclear Information System (INIS)

    2014-06-01

    The position statement focuses on justification in the medical field, in particular on the use of hand-held portable dental x-ray equipment. It supplements another HERCA position paper, providing a general overview of the use of all hand-held portable X-ray equipment. Key Messages: - HERCA finds that the use of hand-held portable X-ray devices should be discouraged except in special circumstances. - As a general rule, these devices should only be used in scenarios where an intraoral radiograph is deemed necessary for a patient and the use of a fixed or semi-mobile x-ray unit is impractical, e.g.: - nursing homes, residential care facilities or homes for persons with disabilities; - forensic odontology, - military operations abroad without dental facilities

  6. Energy Cost of Active and Sedentary Music Video Games: Drum and Handheld Gaming vs. Walking and Sitting.

    Science.gov (United States)

    Miranda, Edwin; Overstreet, Brittany S; Fountain, William A; Gutierrez, Vincent; Kolankowski, Michael; Overstreet, Matthew L; Sapp, Ryan M; Wolff, Christopher A; Mazzetti, Scott A

    2017-01-01

    To compare energy expenditure during and after active and handheld video game drumming compared to walking and sitting. Ten experienced, college-aged men performed four protocols (one per week): no-exercise seated control (CTRL), virtual drumming on a handheld gaming device (HANDHELD), active drumming on drum pads (DRUM), and walking on a treadmill at ~30% of VO 2max (WALK). Protocols were performed after an overnight fast, and expired air was collected continuously during (30min) and after (30min) exercise. DRUM and HANDHELD song lists, day of the week, and time of day were identical for each participant. Significant differences (p DRUM > HANDHELD. No significant differences in the rates of energy expenditure among groups during recovery were observed. Total energy expenditure was significantly greater (p < 0.05) during WALK (149.5 ± 30.6 kcal) compared to DRUM (118.7 ± 18.8 kcal) and HANDHELD (44.9±11.6 kcal), and greater during DRUM compared to HANDHELD. Total energy expenditure was not significantly different between HANDHELD (44.9 ± 11.6 kcal) and CTRL (38.2 ± 6.0 kcal). Active video game drumming at expert-level significantly increased energy expenditure compared to handheld, but it hardly met moderate-intensity activity standards, and energy expenditure was greatest during walking. Energy expenditure with handheld video game drumming was not different from no-exercise control. Thus, traditional aerobic exercise remains at the forefront for achieving the minimum amount and intensity of physical activity for health, individuals desiring to use video games for achieving weekly physical activity recommendations should choose games that require significant involvement of lower-body musculature, and time spent playing sedentary games should be a limited part of an active lifestyle.

  7. Handheld Microfluidic Blood Ananlyzer, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Nanohmics proposes to develop a handheld blood analyzer for micro- and hypo-gravity missions. The prototype instrument will combine impedance analysis with optical...

  8. Augmented Reality Simulations on Handheld Computers

    Science.gov (United States)

    Squire, Kurt; Klopfer, Eric

    2007-01-01

    Advancements in handheld computing, particularly its portability, social interactivity, context sensitivity, connectivity, and individuality, open new opportunities for immersive learning environments. This article articulates the pedagogical potential of augmented reality simulations in environmental engineering education by immersing students in…

  9. Handheld CAT Video Game, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed project is to design, develop and fabricate a handheld video game console for astronauts during long space flight. This portable hardware runs...

  10. A handheld support system to facilitate stereological measurements and mapping of branching structures

    DEFF Research Database (Denmark)

    Gardi, J.E.; Wulfsohn, Dvora-Laiô; Nyengaard, J.R.

    2007-01-01

    specifications, software and Graphical User Interface (GUI) development, functionality and application of the handheld system using four examples: (1) sampling monkey lung bronchioles for estimation of diameter and wall thickness (2) sampling rat kidney for estimating number of arteries and arterioles......‘BranchSampler' is a system for computer-assisted manual stereology written for handheld devices running Windows CE. The system has been designed specifically to streamline data collection and optimize sampling of tree-like branching structures, with particular aims of reducing user errors, saving...

  11. A hand-held beta imaging probe for FDG.

    Science.gov (United States)

    Singh, Bipin; Stack, Brendan C; Thacker, Samta; Gaysinskiy, Valeriy; Bartel, Twyla; Lowe, Val; Cool, Steven; Entine, Gerald; Nagarkar, Vivek

    2013-04-01

    Advances in radiopharmaceuticals and clinical understanding have escalated the use of intraoperative gamma probes in surgery. However, most probes on the market are non-imaging gamma probes that suffer from the lack of ancillary information of the surveyed tissue area. We have developed a novel, hand-held digital Imaging Beta Probe™ (IBP™) to be used in surgery in conjunction with beta-emitting radiopharmaceuticals such as (18)FDG, (131)I and (32)P for real-time imaging of a surveyed area with higher spatial resolution and sensitivity and greater convenience than existing instruments. We describe the design and validation of a hand-held beta probe intended to be used as a visual mapping device to locate and confirm excision of (18)FDG-avid primary tumors and metastases in an animal model. We have demonstrated a device which can generate beta images from (18)FDG avid lesions in an animal model. It is feasible to image beta irradiation in animal models of cancer given (18)FDG. This technology may be applied to clinical mapping of tumors and/or their metastases in the operating room. Visual image depiction of malignancy may aid the surgeon in localization and excision of lesions of interest.

  12. Criteria for a comparative assessment on handheld gamma-ray measurement tools

    International Nuclear Information System (INIS)

    Feichtinger, J.; Schwaiger, M.; Schmitzer, C.; Kindl, P.

    2001-01-01

    Full text: The radionuclide laboratories at the Austrian Research Centres Seibersdorf are strongly involved in radiation protection of public and employees as well as in environmental monitoring with special concern to gamma spectrometric measurements. Hence, field measurements and therefore the subject of hand-held measurement devices is a topic of main interest. Taking into consideration, that these hand-held measurement tool are further used in critical and sensitive operations, as for example by the IAEA Safeguards or by CTBTO On-Site inspectors, a standard for characterising these gamma measurement tools seems to be sound as necessary. The poster presents a set of technical criteria as well as limiting values, which allows an objective comparison of hand-held measurement devices. The criteria can be divided into three individual parts: radiometric characteristics, ergonomics and usability in field operations. The main criteria for testing the radiometry performance of hand-held measurement devices are sensitivity, efficiency, energy response, energy resolution and nuclide identification or not identification (if necessary), detection probability, dose rate indication, uncertainty, etc. The ergonomic test contains as dominating parts handling and quality of the manual. To evaluate the applicability in field operations different environmental conditions (e.g. light conditions, temperature range, moisture...) as well as battery lifetime and weight should be taken into account. These criteria may vary in dependence of the requirements or limitations given by various external conditions, but still a standard to evaluate and will give the opportunity to provide an objective comparison. (author)

  13. Celebral computerized tomography

    International Nuclear Information System (INIS)

    Lofteroed, B.; Sortland, O.

    1985-01-01

    Indications for cerebral computerized tomography (CT) and the diagnostic results from this examination are evaluated in 127 children. Pathological changes were found in 31 children, mostly based on such indications as increasing head size, suspicion of brain tumor, cerebral paresis, delayed psychomotor development and epileptic seizures. A list of indications for CT in children is given

  14. Hand-held spectrophotometer design for textile fabrics

    Science.gov (United States)

    Böcekçi, Veysel Gökhan; Yıldız, Kazım

    2017-09-01

    In this study, a hand-held spectrophotometer was designed by taking advantage of the developments in modern optoelectronic technology. Spectrophotometer devices are used to determine the color information from the optic properties of the materials. As an alternative to a desktop spectrophotometer device we have implemented, it is the first prototype, low cost and portable. The prototype model designed for the textile industry can detect the color tone of any fabric. The prototype model consists of optic sensor, processor, display floors. According to the color applied on the optic sensor, it produces special frequency information on its output at that color value. In Arduino type processor, the frequency information is evaluated by the program we have written and the color tone information between 0-255 ton is decided and displayed on the screen.

  15. Driver electronic device use in 2013.

    Science.gov (United States)

    2015-04-01

    The percentage of drivers text-messaging or visibly manipulating : hand-held devices increased from 1.5 percent in : 2012 to 1.7 percent in 2013; however, this was not a statistically : significant increase. Driver hand-held cell phone : use decrease...

  16. PROSPECTIVE EVALUATION OF VISUAL ACUITY AGREEMENT BETWEEN STANDARD EARLY TREATMENT DIABETIC RETINOPATHY STUDY CHART AND A HANDHELD EQUIVALENT IN EYES WITH RETINAL PATHOLOGY.

    Science.gov (United States)

    Rahimy, Ehsan; Reddy, Sahitya; DeCroos, Francis Char; Khan, M Ali; Boyer, David S; Gupta, Omesh P; Regillo, Carl D; Haller, Julia A

    2015-08-01

    To evaluate the visual acuity agreement between a standard back-illuminated Early Treatment Diabetic Retinopathy Study (ETDRS) chart and a handheld internally illuminated ETDRS chart. Two-center prospective study. Seventy patients (134 eyes) with retinal pathology were enrolled between October 2012 and August 2013. Visual acuity was measured using both the ETDRS chart and the handheld device by masked independent examiners after best protocol refraction. Examination was performed in the same room under identical illumination and testing conditions. The mean number of letters seen was 63.0 (standard deviation: 19.8 letters) and 61.2 letters (standard deviation: 19.1 letters) for the ETDRS chart and handheld device, respectively. Mean difference per eye between the ETDRS and handheld device was 1.8 letters. A correlation coefficient (r) of 0.95 demonstrated a positive linear correlation between ETDRS chart and handheld device measured acuities. Intraclass correlation coefficient was performed to assess the reproducibility of the measurements made by different observers measuring the same quantity and was calculated to be 0.95 (95% confidence interval: 0.93-0.96). Agreement was independent of retinal disease. The strong correlation between measured visual acuity using the ETDRS and handheld equivalent suggests that they may be used interchangeably, with accurate measurements. Potential benefits of this device include convenience and portability, as well as the ability to assess ETDRS visual acuity without a dedicated testing lane.

  17. Computerized industrial tomography

    International Nuclear Information System (INIS)

    Ashraf, M.M.

    1999-01-01

    Computerized Tomographic (CT) has been used for a number of applications in the field of medicine and industry. For the last couple of years, the technique has been applied for the material characterization and detection of defects and flaws inside the industrial components of nuclear, aerospace and missile industries. A CT scanner of first generation was developed at the institute. The scanner has been used to demonstrate couple of applications of CT in the field of non destructive testing of materials. The data acquired by placing the test objects at various angles and scanning the object through a source detector assembly has been processed on a Pentium computer for image reconstruction using a filtered back projection method. The technique has been developed which can be modified and improved to study various other applications in materials science and a modern computerized tomographic facility can be established. (author)

  18. 30 CFR 57.12033 - Hand-held electric tools.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...

  19. 30 CFR 56.12033 - Hand-held electric tools.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL....12033 Hand-held electric tools. Hand-held electric tools shall not be operated at high potential...

  20. Elbow joint position sense after neuromuscular training with handheld vibration.

    Science.gov (United States)

    Tripp, Brady L; Faust, Donald; Jacobs, Patrick

    2009-01-01

    Clinicians use neuromuscular control exercises to enhance joint position sense (JPS); however, because standardizing such exercises is difficult, validations of their use are limited. To evaluate the acute effects of a neuromuscular training exercise with a handheld vibrating dumbbell on elbow JPS acuity. Crossover study. University athletic training research laboratory. Thirty-one healthy, college-aged volunteers (16 men, 15 women, age = 23 + or - 3 years, height = 173 + or - 8 cm, mass = 76 + or - 14 kg). We measured and trained elbow JPS using an electromagnetic tracking device that provided auditory and visual biofeedback. For JPS testing, participants held a dumbbell and actively identified the target elbow flexion angle (90 degrees ) using the software-generated biofeedback, followed by 3 repositioning trials without feedback. Each neuromuscular training protocol included 3 exercises during which participants held a 2.55-kg dumbbell vibrating at 15, 5, or 0 Hz and used software-generated biofeedback to locate and maintain the target elbow flexion angle for 15 seconds. We calculated absolute (accuracy) and variable (variability) errors using the differences between target and reproduced angles. Training protocols using 15-Hz vibration enhanced accuracy and decreased variability of elbow JPS (P or = .200). Our results suggest these neuromuscular control exercises, which included low-magnitude, low-frequency handheld vibration, may enhance elbow JPS. Future researchers should examine vibration of various durations and frequencies, should include injured participants and functional multijoint and multiplanar measures, and should examine long-term effects of training protocols on JPS and injury.

  1. Computerized plant maintenance management

    International Nuclear Information System (INIS)

    Kozusko, A.M.

    1986-01-01

    The evolution of the computer has and continues to have a great impact on industry. We are in an adjustment cycle with the current computer evolution, and will need to adapt to make the changes for the coming decade. Hardware and software are continually being enhanced. Computers are becoming more powerful and will eventually provide an effective man-machine interface. This paper shares experiences encountered during implementations of computerized maintenance systems

  2. Computerized medical convocations

    International Nuclear Information System (INIS)

    Roche, Annie; Gilbert, Jean-Francois; Chiadot, Pierre; Vanzetto, Rene; Darnault, Jean

    1969-06-01

    Thanks to a close collaboration between the Medical and Social department and the Numerical Calculation Laboratory, a computerized convocation system has been implemented to reduce the administrative workload and to introduce more rigor in medical management, patient historical background and statistics. This work comprises: - a preliminary study of the data generating medical convocations and the related practical requirements; - the programming work according to these data; - the realisation of the mechano-graphical file covering the overall personnel [fr

  3. Font size and viewing distance of handheld smart phones.

    Science.gov (United States)

    Bababekova, Yuliya; Rosenfield, Mark; Hue, Jennifer E; Huang, Rae R

    2011-07-01

    The use of handheld smart phones for written communication is becoming ubiquitous in modern society. The relatively small screens found in these devices may necessitate close working distances and small text sizes, which can increase the demands placed on accommodation and vergence. Font size and viewing distance were measured while subjects used handheld electronic devices in two separate trials. In the first study (n=129), subjects were asked to show a typical text message on their own personal phone and to hold the device "as if they were about to read a text message." A second trial was conducted in a similar manner except subjects (n=100) were asked to view a specific web page from the internet. For text messages and internet viewing, the mean font size was 1.1 M (range, 0.7 to 2.1 M) and 0.8 M (range, 0.3 to 1.4 M), respectively. The mean working distance for text messages and internet viewing was 36.2 cm (range, 17.5 to 58.0 cm) and 32.2 cm (range, 19 to 60 cm), respectively. The mean font size for both conditions was comparable with newspaper print, although some subjects viewed text that was considerably smaller. However, the mean working distances were closer than the typical near working distance of 40 cm for adults when viewing hardcopy text. These close distances place increased demands on both accommodation and vergence, which could exacerbate symptoms. Practitioners need to consider the closer distances adopted while viewing material on smart phones when examining patients and prescribing refractive corrections for use at near, as well as when treating patients presenting with asthenopia associated with nearwork. Copyright © 2011 American Academy of Optometry

  4. Handheld spectrometers: the state of the art

    Science.gov (United States)

    Crocombe, Richard A.

    2013-05-01

    "Small" spectrometers fall into three broad classes: small versions of laboratory instruments, providing data, subsequently processed on a PC; dedicated analyzers, providing actionable information to an individual operator; and process analyzers, providing quantitative or semi-quantitative information to a process controller. The emphasis of this paper is on handheld dedicated analyzers. Many spectrometers have historically been large, possible fragile, expensive and complicated to use. The challenge over the last dozen years, as instruments have moved into the field, has been to make spectrometers smaller, affordable, rugged, easy-to-use, but most of all capable of delivering actionable results. Actionable results can dramatically improve the efficiency of a testing process and transform the way business is done. There are several keys to this handheld spectrometer revolution. Consumer electronics has given us powerful mobile platforms, compact batteries, clearly visible displays, new user interfaces, etc., while telecomm has revolutionized miniature optics, sources and detectors. While these technologies enable miniature spectrometers themselves, actionable information has demanded the development of rugged algorithms for material confirmation, unknown identification, mixture analysis and detection of suspicious materials in unknown matrices. These algorithms are far more sophisticated than the `correlation' or `dot-product' methods commonly used in benchtop instruments. Finally, continuing consumer electronics advances now enable many more technologies to be incorporated into handheld spectrometers, including Bluetooth, wireless, WiFi, GPS, cameras and bar code readers, and the continued size shrinkage of spectrometer `engines' leads to the prospect of dual technology or `hyphenated' handheld instruments.

  5. Object localization in handheld thermal images for fireground understanding

    Science.gov (United States)

    Vandecasteele, Florian; Merci, Bart; Jalalvand, Azarakhsh; Verstockt, Steven

    2017-05-01

    Despite the broad application of the handheld thermal imaging cameras in firefighting, its usage is mostly limited to subjective interpretation by the person carrying the device. As remedies to overcome this limitation, object localization and classification mechanisms could assist the fireground understanding and help with the automated localization, characterization and spatio-temporal (spreading) analysis of the fire. An automated understanding of thermal images can enrich the conventional knowledge-based firefighting techniques by providing the information from the data and sensing-driven approaches. In this work, transfer learning is applied on multi-labeling convolutional neural network architectures for object localization and recognition in monocular visual, infrared and multispectral dynamic images. Furthermore, the possibility of analyzing fire scene images is studied and their current limitations are discussed. Finally, the understanding of the room configuration (i.e., objects location) for indoor localization in reduced visibility environments and the linking with Building Information Models (BIM) are investigated.

  6. Monitoring of WEEE plastics in regards to brominated flame retardants using handheld XRF

    Energy Technology Data Exchange (ETDEWEB)

    Aldrian, Alexia, E-mail: alexia.aldrian@unileoben.ac.at [Chair of Waste Processing Technology and Waste Management, Montanuniversitaet Leoben, Franz-Josef-Straße 18, 8700 Leoben (Austria); Ledersteger, Alfred, E-mail: a.ledersteger@saubermacher.at [Saubermacher Dienstleistungs AG, Hans-Roth-Straße 1, 8073 Feldkirchen bei Graz (Austria); Pomberger, Roland, E-mail: roland.pomberger@unileoben.ac.at [Chair of Waste Processing Technology and Waste Management, Montanuniversitaet Leoben, Franz-Josef-Straße 18, 8700 Leoben (Austria)

    2015-02-15

    Highlights: • Specification of an empirical factor for conversion from bromine to PBB and PBDE. • The handheld XRF device was validated for this particular application. • A very large number of over 4600 pieces of monitor housings was analysed. • The recyclable fraction mounts up to 85% for TV but only 53% of PC waste plastics. • A high percentage of pieces with bromine contents of over 50,000 ppm was obtained. - Abstract: This contribution is focused on the on-site determination of the bromine content in waste electrical and electronic equipment (WEEE), in particular waste plastics from television sets (TV) and personal computer monitors (PC) using a handheld X-ray fluorescence (XRF) device. The described approach allows the examination of samples in regards to the compliance with legal specifications for polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs) directly after disassembling and facilitates the sorting out of plastics with high contents of brominated flame retardants (BFRs). In all, over 3000 pieces of black (TV) and 1600 pieces of grey (PC) plastic waste were analysed with handheld XRF technique for this study. Especially noticeable was the high percentage of pieces with a bromine content of over 50,000 ppm for TV (7%) and PC (39%) waste plastics. The applied method was validated by comparing the data of handheld XRF with results obtained by GC–MS. The results showed the expected and sufficiently accurate correlation between these two methods. It is shown that handheld XRF technique is an effective tool for fast monitoring of large volumes of WEEE plastics in regards to BFRs for on-site measurements.

  7. Computerized operator decision aids

    International Nuclear Information System (INIS)

    Long, A.B.

    1984-01-01

    This article explores the potential benefits associated with the use of computers in nuclear plants by the operating crew as an aid in making decisions. Pertinent findings are presented from recently completed projects to establish the context in which operating decisions have to be made. Key factors influencing the decision-making process itself are also identified. Safety parameter display systems, which are being implemented in various forms by the nuclear industry, are described within the context of decision making. In addition, relevant worldwide research and development activities are examined as potential enhancements to computerized operator decision aids to further improve plant safety and availability

  8. Computerized procedures system

    Science.gov (United States)

    Lipner, Melvin H.; Mundy, Roger A.; Franusich, Michael D.

    2010-10-12

    An online data driven computerized procedures system that guides an operator through a complex process facility's operating procedures. The system monitors plant data, processes the data and then, based upon this processing, presents the status of the current procedure step and/or substep to the operator. The system supports multiple users and a single procedure definition supports several interface formats that can be tailored to the individual user. Layered security controls access privileges and revisions are version controlled. The procedures run on a server that is platform independent of the user workstations that the server interfaces with and the user interface supports diverse procedural views.

  9. Computerized spleen volumetry

    International Nuclear Information System (INIS)

    Jahnke, T.; Mohring, R.; Schertel, L.

    1981-01-01

    We examined in experimental studies and clinical investigations on 34 patients in how far volumetry of the spleen can be carried out with a commonly available program, a whole-body computerized tomograph (SOMATOM) and an analytic equipment (EVALUSKOP). In this connection the authors tried to find also other ways of spleen volumetry by means of this unit combination. Our final result was that the given program for the usage of labelled areas presents itself as the best-suited technique for spleen volumetry which is also applicable in practice. (orig./MG) [de

  10. Computerized adaptive testing item selection in computerized adaptive learning systems

    NARCIS (Netherlands)

    Eggen, Theodorus Johannes Hendrikus Maria; Eggen, T.J.H.M.; Veldkamp, B.P.

    2012-01-01

    Item selection methods traditionally developed for computerized adaptive testing (CAT) are explored for their usefulness in item-based computerized adaptive learning (CAL) systems. While in CAT Fisher information-based selection is optimal, for recovering learning populations in CAL systems item

  11. Beyond mere information provisioning: a handheld museum guide based on social activities and playful learning

    OpenAIRE

    SCHROYEN, Jolien; GABRIELS, Kris; TEUNKENS, Daniel; ROBERT, Karel; LUYTEN, Kris; CONINX, Karin

    2007-01-01

    During a museum visit, social interaction can improve intellectual, social, personal and cultural development. With the advances in technology, the use of personal mobile handheld devices – such as Personal Digital Assistants (PDAs) – that replace the traditional paper guidebooks is becoming a common sight at various heritage sites all over the world. This technology often leads to problems such as isolating visitors from their companions and distracting visitors away from their surroundings....

  12. 3D interactive topology optimization on hand-held devices

    DEFF Research Database (Denmark)

    Nobel-Jørgensen, Morten; Aage, Niels; Christiansen, Asger Nyman

    2015-01-01

    This educational paper describes the implementation aspects, user interface design considerations and workflow potential of the recently published TopOpt 3D App. The app solves the standard minimum compliance problem in 3D and allows the user to change design settings interactively at any point...... in time during the optimization. Apart from its educational nature, the app may point towards future ways of performing industrial design. Instead of the usual geometrize, then model and optimize approach, the geometry now automatically adapts to the varying boundary and loading conditions. The app...

  13. A prompt information retrieval system on handheld devices

    Science.gov (United States)

    Huang, Yo-Ping; Yen, Wei; Lin, Shi-Hung

    2007-04-01

    In this paper, we propose an intelligent bird information retrieval system which aims to construct a mobility-learning activity under the up-to-date wireless technology. The system consists of a Tablet PC and PDAs with wireless networking capabilities. The PDA is equipped with a friendly retrieval interface and a good learning environment. In our system, users only need to click the buttons or input the keywords to retrieve bird information. Besides, users can discuss or share their information and knowledge via the wireless network. Our system saves bird information in four categories including "Introduction," "Images," "Sound," "Streaming Media," and "Ecological Memo." The integral knowledge helps users understand more about birds. Data mining and fuzzy association rules are applied to recommend users those birds they may be interested in. A streaming server on the Tablet PC is built to provide the streaming media for PDA users. By this way, PDA users can enjoy the multimedia from Tablet PC in real time without downloading completely. Finally, the system is a perfect tool for outdoor teaching and can be easily extended to provide navigation and touring services for national parks or museums.

  14. Information Collection using Handheld Devices in Unreliable Networking Environments

    Science.gov (United States)

    2014-06-01

    joint logistics operations center JMS Java Message System JUNG Java Universal Network/Graph Framework KTG Kestral Technology Group MILOB... Java Message System, a Publisher/Subscriber system that is explained in greater detail at either Oracle’s JMS site (Oracle 2014) or the JMS Wikipedia...Google’s infrastructure and local servers with MySQL and PostgreSQL on the backend (ODK 2014b). (2) Google Fusion Tables are used to do basic link

  15. GPS-based handheld device for mapping contaminated areas

    International Nuclear Information System (INIS)

    Paridaens, J.

    2005-01-01

    Sometimes one is confronted with the challenge to map large areas with enhanced radioactivity. Examples are mine tailings or waste rock piles, deposits of the phosphate industry, flooding zones contaminated by effluents of plants processing ores containing enhanced natural radiation, nuclear accident sites etc. Car borne measuring equipment is not always an option, as the terrain might be rough and only accessible by foot. Airborne mapping with helicopters on the other hand is fast, but expensive, not readily available, shows difficulties with complex topography and lacks the necessary detail. The objective of this study was to create a portable and easily usable tool for the real time logging of radiation and location data, allowing mapping the radioactivity by simply walking over any kind of terrain with the portable equipment and post processing the data in the office. We also assessed the performance of the GPS based system on contaminated sites with areas varying from less than a hectare to several tens of hectares, with respect to speed, precision and ease of use. At sites of large scale mining and processing of uranium ore, tailings and waste rock piles are today the most visible relics of the uranium extractive industry. These mining relics are constantly subjected to weathering and leaching processes causing the dissemination of radioactive and toxic elements and sometimes requiring remedial operations. The in situ remediation of waste rock piles usually includes their revegetation for minimizing the water infiltration and for increasing surface soil stability. Thanks to its biomass density and longevity, the perennial vegetation plays an important role in stabilisation of the water cycling. The buffer role of forest vegetation can reduce water export from watersheds as well as erosion and hydrological losses of chemicals including radionuclides from contaminated sites. If long term reduction of contaminant dispersion at revegetated uranium mining sites is to be fully appreciated, then the extent of radioactive contaminant availability to forest vegetation and ecosystem cycling as well as the possible economic valorisation of the woody products must be considered

  16. Thessaloniki's City Guide: a Tourist Site for Handheld Devices

    Science.gov (United States)

    Theodorou, Niki

    Mobile browsing is expected to become very popular during the next decade. Users will connect to the Internet and use a mobile browser as an every day tool, usually as a part of their mobile telephone. Many services that would be relevant for mobile use are location or time dependent such as: tourist information; maps; and train timetables. This paper describes step by step the production of the mobile tourist site of the city of Thessaloniki Greece. In the paper both the marketing strategies and the mobile site development techniques are included.

  17. Computerized tomographic system

    International Nuclear Information System (INIS)

    Godbarsen, R.; Barrett, D.M.; Garrott, P.M.; Foley, L.E.; Redington, R.W.; Lambert, T.W.; Edelheit, L.S.

    1981-01-01

    A computerized tomographic system for examining human breasts is described in detail. Conventional X-ray scanning apparatus has difficulty in achieving the levels of image definition and examination speeds required for mass screening. A novel method of scanning successive layers of the breast with a rotating X-ray beam is discussed and details of the control circuitry and sequence steps are given. The method involves immersing the breast in an inner fluid (e.g. water) filled container which is stationary during an examination and is surrounded by a large outer container which is also filled with the fluid; the inner and outer containers are always maintained at a constant height and the X-ray absorption across the fan-shaped beam is as close as possible to constant. (U.K.)

  18. Active case finding strategy for chronic obstructive pulmonary disease with handheld spirometry.

    Science.gov (United States)

    Kim, Joo Kyung; Lee, Chang Min; Park, Ji Young; Kim, Joo Hee; Park, Sung-Hoon; Jang, Seung Hun; Jung, Ki-Suck; Yoo, Kwang Ha; Park, Yong Bum; Rhee, Chin Kook; Kim, Deog Kyeom; Hwang, Yong Il

    2016-12-01

    The early detection and diagnosis of chronic obstructive pulmonary disease (COPD) is critical to providing appropriate and timely treatment. We explored a new active case-finding strategy for COPD using handheld spirometry.We recruited subjects over 40 years of age with a smoking history of more than 10 pack-years who visited a primary clinic complaining of respiratory symptoms. A total of 190 of subjects were enrolled. Medical information was obtained from historical records and physical examination by general practitioners. All subjects had their pulmonary function evaluated using handheld spirometry with a COPD-6 device. Because forced expiratory volume in 6 seconds (FEV6) has been suggested as an alternative to FVC, we measured forced expiratory volume in 1 second (FEV1)/FEV6 for diagnosis of airflow limitation. All subjects were then referred to tertiary referral hospitals to complete a "Could it be COPD?" questionnaire, handheld spiromtery, and conventional spirometry. The results of each instrument were compared to evaluate the efficacy of both handheld spirometry and the questionnaire.COPD was newly diagnosed in 45 (23.7%) patients. According to our receiver-operating characteristic (ROC) curve analysis, sensitivity and specificity were maximal when the FEV1/FEV6 ratio was less than 77%. The area under the ROC curve was 0.759. The sensitivity, specificity, positive predictive value, and negative predictive value were 72.7%, 77.1%, 50%, and 90%, respectively. The area under the ROC curve of respiratory symptoms listed on the questionnaire ranged from 0.5 to 0.65, which indicates that there is almost no difference compared with the results of handheld spirometry.The present study demonstrated the efficacy of handheld spirometry as an active case-finding tool for COPD in a primary clinical setting. This study suggested that physicians should recommend handheld spirometry for people over the age of 40, who have a smoking history of more than 10 pack

  19. SAFARI 2000 Atmospheric Aerosol Measurements, Hand-held Hazemeters, Zambia

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: In conjunction with the AERONET (AErosol RObotic NETwork) participation in SAFARI 2000, the USDA Forest Service deployed handheld hazemeters in western...

  20. Handheld single photon emission computed tomography (handheld SPECT) navigated video-assisted thoracoscopic surgery of computer tomography-guided radioactively marked pulmonary lesions.

    Science.gov (United States)

    Müller, Joachim; Putora, Paul Martin; Schneider, Tino; Zeisel, Christoph; Brutsche, Martin; Baty, Florent; Markus, Alexander; Kick, Jochen

    2016-09-01

    Radioactive marking can be a valuable extension to minimally invasive surgery. The technique has been clinically applied in procedures involving sentinel lymph nodes, parathyroidectomy as well as interventions in thoracic surgery. Improvements in equipment and techniques allow one to improve the limits. Pulmonary nodules are frequently surgically removed for diagnostic or therapeutic reasons; here video-assisted thoracoscopic surgery (VATS) is the preferred technique. VATS might be impossible with nodules that are small or located deep in the lung. In this study, we examined the clinical application and safety of employing the newly developed handheld single photon emission tomography (handheld SPECT) device in combination with CT-guided radioactive marking of pulmonary nodules. In this pilot study, 10 subjects requiring surgical resection of a pulmonary nodule were included. The technique involved CT-guided marking of the target nodule with a 20-G needle, with subsequent injection of 25-30 MBq (effective: 7-14 MBq) Tc-99m MAA (Macro Albumin Aggregate). Quality control was made with conventional SPECT-CT to confirm the correct localization and exclude possible complications related to the puncture procedure. VATS was subsequently carried out using the handheld SPECT to localize the radioactivity intraoperatively and therefore the target nodule. A 3D virtual image was superimposed on the intraoperative visual image for surgical guidance. In 9 of the 10 subjects, the radioactive application was successfully placed directly in or in the immediate vicinity of the target nodule. The average size of the involved nodules was 9 mm (range 4-15). All successfully marked nodules were subsequently completely excised (R0) using VATS. The procedure was well tolerated. An asymptomatic clinically insignificant pneumothorax occurred in 5 subjects. Two subjects were found to have non-significant discrete haemorrhage in the infiltration canal of the needle. In a single subject, the

  1. Hand-held and automated breast ultrasound

    International Nuclear Information System (INIS)

    Bassett, L.W.; Gold, R.H.; Kimme-Smith, C.

    1985-01-01

    The book is a guide for physicians and technologists who use US as an adjunct to mammography; it carefully outlines the pros and cons of US of the breast and its role in the diagnosis of benign and malignant diseases. After an introduction that discusses the philosophy of breast US, the chapters cover the physics of US and instrumentation (both hand-held transducers as well as automated water path scanners), then proceed to a discussion of the normal breast. Sections on benign disorders, malignant lesions, and pitfalls of diagnosis are followed by quiz cases

  2. Neuroradiology Using Secure Mobile Device Review.

    Science.gov (United States)

    Randhawa, Privia A; Morrish, William; Lysack, John T; Hu, William; Goyal, Mayank; Hill, Michael D

    2016-04-05

    Image review on computer-based workstations has made film-based review outdated. Despite advances in technology, the lack of portability of digital workstations creates an inherent disadvantage. As such, we sought to determine if the quality of image review on a handheld device is adequate for routine clinical use. Six CT/CTA cases and six MR/MRA cases were independently reviewed by three neuroradiologists in varying environments: high and low ambient light using a handheld device and on a traditional imaging workstation in ideal conditions. On first review (using a handheld device in high ambient light), a preliminary diagnosis for each case was made. Upon changes in review conditions, neuroradiologists were asked if any additional features were seen that changed their initial diagnoses. Reviewers were also asked to comment on overall clinical quality and if the handheld display was of acceptable quality for image review. After the initial CT review in high ambient light, additional findings were reported in 2 of 18 instances on subsequent reviews. Similarly, additional findings were identified in 4 of 18 instances after the initial MR review in high ambient lighting. Only one of these six additional findings contributed to the diagnosis made on the initial preliminary review. Use of a handheld device for image review is of adequate diagnostic quality based on image contrast, sharpness of structures, visible artefacts and overall display quality. Although reviewers were comfortable with using this technology, a handheld device with a larger screen may be diagnostically superior.

  3. Handheld Versus Wearable Interaction Design for Professionals - A Case Study of Hospital Service Work

    DEFF Research Database (Denmark)

    Stisen, Allan; Blunck, Henrik; Kjærgaard, Mikkel Baun

    2014-01-01

    With the blooming of new available wrist worn devices there are potentials for these to support the work done in many professional domains. One such domain is hospital service work. This paper explores two wearable prototypes with regards to challenges and opportunities to support future hospital...... service work. This explorative study was conducted with 4 experienced hospital orderlies who interacted with an application across two wearable concepts, and one handheld smartphone in five scenarios in a hospital environment. The interaction was video recorded with a chest-mounted video afterwards semi...... structured interviews with each participant was conducted. This study shows that wearable computers can effectively support the maintenance work of the orderlies and has domain specific advantages over the handheld smartphone, e.g., the former support glancing at the task information. Furthermore, we outline...

  4. Computerized tomography in myotonic dystrophy

    International Nuclear Information System (INIS)

    Gellerich, I.; Mueller, D.; Koch, R.D.

    1986-01-01

    Besides clinical symptoms, progress and electromyography computerized tomography improves the diagnostics of myotonic dystrophy. Even small changes in muscular structure are detectable and especially the musculus soleus exhibits early and pronounced alterations. By means of density distribution pattern an improved characterization of the disease is possible. Additional information is obtained by cerebral computerized tomography. Atrophy of brain tissue is to be expected in all patients with myotonic dystrophy. (author)

  5. Computerized radiation treatment planning

    International Nuclear Information System (INIS)

    Laarse, R. van der.

    1981-01-01

    Following a general introduction, a chain consisting of three computer programs which has been developed for treatment planning of external beam radiotherapy without manual intervention is described. New score functions used for determination of optimal incidence directions are presented and the calculation of the position of the isocentre for each optimum combination of incidence directions is explained. A description of how a set of applicators, covering fields with dimensions of 4 to 20 cm, for the 6 to 20 MeV electron beams of a MEL SL75-20 linear accelerator was developed, is given. A computer program for three dimensional electron beam treatment planning is presented. A microprocessor based treatment planning system for the Selectron remote controlled afterloading system for intracavitary radiotherapy is described. The main differences in treatment planning procedures for external beam therapy with neutrons instead of photons is discussed. A microprocessor based densitometer for plotting isodensity lines in film dosimetry is described. A computer program for dose planning of brachytherapy is presented. Finally a general discussion about the different aspects of computerized treatment planning as presented in this thesis is given. (Auth.)

  6. Radioactive waste computerized management

    International Nuclear Information System (INIS)

    Communaux, M.; Lantes, B.

    1993-01-01

    Since December 31, 1990, the management of the nuclear wastes for all the power stations has been computerized, using the DRA module of the Power Generation and Transmission Group's data processing master plan. So now EDF has a software package which centralizes all the data, enabling it to declare the characteristics of the nuclear wastes which are to be stored on the sites operated by the National Radioactive Waste Management Agency (ANDRA). Among other uses, this application makes it possible for EDF, by real time data exchange with ANDRA, to constitute an inventory of validated, shippable packs. It also constitutes a data base for all the wastes produced on the various sites. This application was developed to meet the following requirements: give the producers of radioactive waste a means to fully manage all the characteristics and materials that are necessary to condition their waste correctly; guarantee the traceability and safety of data and automatically assure the transmission of this data in real time between the producers and the ANDRA; give the Central Services of EDF an operation and statistical tool permitting an experienced feed-back based on the complete national production (single, centralized data base); and integrate the application within the products of the processing master plan in order to assure its maintenance and evolution

  7. Computerized literature reference system: use of an optical scanner and optical character recognition software.

    Science.gov (United States)

    Lossef, S V; Schwartz, L H

    1990-09-01

    A computerized reference system for radiology journal articles was developed by using an IBM-compatible personal computer with a hand-held optical scanner and optical character recognition software. This allows direct entry of scanned text from printed material into word processing or data-base files. Additionally, line diagrams and photographs of radiographs can be incorporated into these files. A text search and retrieval software program enables rapid searching for keywords in scanned documents. The hand scanner and software programs are commercially available, relatively inexpensive, and easily used. This permits construction of a personalized radiology literature file of readily accessible text and images requiring minimal typing or keystroke entry.

  8. Handheld emissions detector (HED): overview and development

    Science.gov (United States)

    Valentino, George J.; Schimmel, David

    2009-05-01

    Nova Engineering, Cincinnati OH, a division of L-3 Communications (L-3 Nova), under the sponsorship of Program Manager Soldier Warrior (PM-SWAR), Fort Belvoir, VA, has developed a Soldier portable, light-weight, hand-held, geolocation sensor and processing system called the Handheld Emissions Detector (HED). The HED is a broadband custom receiver and processor that allows the user to easily sense, direction find, and locate a broad range of emitters in the user's surrounding area. Now in its second design iteration, the HED incorporates a set of COTS components that are complemented with L-3 Nova custom RF, power, digital, and mechanical components, plus custom embedded and application software. The HED user interfaces are designed to provide complex information in a readily-understandable form, thereby providing actionable results for operators. This paper provides, where possible, the top-level characteristics of the HED as well as the rationale behind its design philosophy along with its applications in both DOD and Commercial markets.

  9. Navigating on handheld displays: Dynamic versus Static Keyhole Navigation

    NARCIS (Netherlands)

    Mehra, S.; Werkhoven, P.; Worring, M.

    2006-01-01

    Handheld displays leave little space for the visualization and navigation of spatial layouts representing rich information spaces. The most common navigation method for handheld displays is static peephole navigation: The peephole is static and we move the spatial layout behind it (scrolling). A

  10. Computerized data treatment technology

    International Nuclear Information System (INIS)

    Ferguson, R.B.; Maddox, J.H.; Wren, H.F.

    1977-01-01

    The Savannah River Laboratory (SRL) has accepted responsibility for a hydrogeochemical and stream-sediment reconnaissance in 25 eastern states as part of the National Uranium Resource Evaluation (NURE). SRL has developed a computerized program for recording, processing, updating, retrieving, and analyzing hydrogeochemical data from this reconnaissance. This program will handle an expected 150 million bytes of hydrogeochemical data from 150,000 to 200,000 sample sites over the next four years. The SRL--NURE hydrogeochemical data management system is written in FORTRAN IV for an IBM System 360/195 computer and is designed to easily accommodate changes in types of collected data and input format. As the data become available, they are accepted and combined with relevant data already in the system. SRL also developed a sample inventory and control system and a graphics and analysis system. The sample inventory and control system accounts for the movements of all samples and forms from initial receipt through final storage. Approximately six million sample movements are expected. The graphics and analysis system provides easily usable programs for reporting and interpreting data. Because of the large volume of data to be interpreted, the graphics and analysis system plays a central role in the hydrogeochemical program. Programs developed to provide two- and three-dimensional plots of sampled geographic areas show concentrations and locations of individual variables which are displayed and reproduced photographically. Pattern recognition techniques are also available, and they allow multivariate data to be categorized into ''clusters,'' which may indicate sites favorable for uranium exploration

  11. Handheld Multi-Gas Meters Assessment Report

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Gustavious [Brigham Young Univ., Provo, UT (United States); Wald-Hopkins, Mark David [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Obrey, Stephen J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Akhadov, Valida Dushdurova [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-27

    Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the monitored chemical. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. In April 2016 the System Assessment and Validation for Emergency Responders (SAVER) Program conducted an operationally-oriented assessment of MGMs. Five MGMs were assessed by emergency responders. The criteria and scenarios used in this assessment were derived from the results of a focus group of emergency responders with experience in using MGMs. The assessment addressed 16 evaluation criteria in four SAVER categories: Usability, Capability, Maintainability, and Deployability.

  12. Abdominoplasty and seroma: a prospective randomised study comparing scalpel and handheld electrocautery dissection.

    Science.gov (United States)

    Marsh, Dan J; Fox, Andreas; Grobbelaar, Adriaan O; Chana, Jagdeep S

    2015-02-01

    Seroma formation remains a significant problem in abdominoplasty procedures--the cause of which remains to be elucidated. It has been suggested that one of the causative factors for seroma formation is the use of handheld electrocautery as opposed to scalpel for abdominal flap dissection. Prospective trial in 102 consecutive abdominoplasty patients randomised to have abdominal flap dissection with either handheld electrocautery device on 'coagulation setting' or sharp dissection with scalpel and monopolar electrocautery forceps for haemostasis. In all other aspects the surgical technique was identical between the two groups. All drains were removed at 48 h, irrespective of drain volume. Primary outcome measure is postoperative seroma formation on clinical examination, secondary outcome measures are drain volume, weight of tissue removed, effect of liposuction and patient BMI. Both study groups were similar in demographics with no significant difference in weight of tissue excised, BMI, drain output or post operative complictions. There was no significant difference in seroma formation rates between the handheld electrocautery group (17.2%) and the sharp dissection group (20.1%). Overall, the seroma rate was 18.6%. Liposuction to the flanks at the time of abdominoplasty was found to significantly increase the incidence of seroma, compared to patients having abdominoplasty alone. Use of handheld electrocautery rather than scalpel for tissue dissection does not lead to increased seroma formation in abdominoplasty patients. Concomitant liposuction at the time of abdominoplasty increases the risk of seroma formation compared to patients having abdominoplasty alone. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Diagnostic perspectives of mobile x-ray computerized tomography

    International Nuclear Information System (INIS)

    Portnoj, L.M.; Dibirov, M.P.; Denisova, L.B.

    1992-01-01

    Mobile x-ray computerized tomography (CT) and an organization and methodological scheme of its application were assessed. CT is realized in special hospitals of large regions, where the patients with the optimal indications for CT are assembled. Over 15000 examinations were carried out with the use of the suggested CT program over 4 years, that resulted in detection of 1295 brain tumors, 804 cases with neoplastic involvement of the abdominal cavity and the retroperitoneal space. Wide application of mobile CT devices according to the program will help to decide the problem of unavailability of such examinations. One mobile device may replace 3 permanent CT devices

  14. Some aspects of evaluation of image quality in computerized tomography

    International Nuclear Information System (INIS)

    Travassos, Paulo Cesar Baptista; Peixoto, Jose Guilherme; Almeida, Carlos Eduardo Veloso de; Campos, Luciana Tourinho; Magalhaes, Luis Alexandre

    2016-01-01

    The evaluation of CT scanners image quality includes measuring the Hounsfield values, HU, using a table with the limit values. This table does not consider that different devices have different effective energies, which may cause some false results. The evaluation of 90 computerized tomography, by the American College Radiology methodology, showed that some failed devices in the evaluation showed excellent linear fit between the values of the linear attenuation coefficients calculated for the actual energy used, according to the HU values. The analysis of the coefficient of determination suggests that 10 of these devices could have been approved. (author)

  15. Hand-held tidal breathing nasal nitric oxide measurement--a promising targeted case-finding tool for the diagnosis of primary ciliary dyskinesia

    DEFF Research Database (Denmark)

    Marthin, June Kehlet; Nielsen, Kim Gjerum

    2013-01-01

    BACKGROUND: Nasal nitric oxide (nNO) measurement is an established first line test in the work-up for primary ciliary dyskinesia (PCD). Tidal breathing nNO (TB-nNO) measurements require minimal cooperation and are potentially useful even in young children. Hand-held NO devices are becoming...... increasingly widespread for asthma management. Therefore, we chose to assess whether hand-held TB-nNO measurements reliably discriminate between PCD, and Healthy Subjects (HS) and included Cystic Fibrosis (CF) patients as a disease control group known to have intermediate nNO levels. METHODS: In this cross...... sectional, single centre, single occasion, proof-of-concept study in children and adults with PCD and CF, and in HS we compared feasibility, success rates, discriminatory capacity, repeatability and agreement between a hand-held electrochemical device equipped with a nNO software application sampling...

  16. Plans for Hand-Held/Portable Oil Assessment Devices

    National Research Council Canada - National Science Library

    Urbansky, Edward

    2005-01-01

    At the request of the U.S. Army Oil Analysis Program, the JOAP TSC conducted a market study, assembled a plan of action, and prepared a worksheet for the evaluation of portable or hand-held oil assessment devices...

  17. Architectural Vulnerabilities of Third-Generation Portable Devices

    National Research Council Canada - National Science Library

    Chin, Shiu-Kai

    2007-01-01

    .... We developed a handheld evidence recovery operator to address the challenges created by user passwords and PINs, and a standalone tool to copy the data located on the device to an external storage...

  18. Technologies in computerized lexicography | Kruyt | Lexikos

    African Journals Online (AJOL)

    Although the topic of this paper is technology, focus is on functional rather than technical aspects of computerized lexicography. Keywords: computerized lexicography, electronic dictionary, electronic text corpus, lexicographer's workbench, integrated language database, automatic linguistic analysis, information retrieval, ...

  19. Computerized techniques for collecting the radioprotection data

    International Nuclear Information System (INIS)

    Cenusa, V.; Valeca, S.; Guta, C.; Talpalariu, C.; Stoica, V.

    2016-01-01

    An important component of a computerized radioprotection system is the module for the collection of the radioprotection data. The data collection can be made automatically from the measurement equipment or manually by the operators after they read the values measured by the mobile devices. Database systems are used for storing the data, they offer higher performances, more efficient data organization, ensure data integrity and controlled access to the data into a multiuser environment. The experimental program for the automatic collection of the remote data transfers periodically, at programmable time intervals, data files from the fixed radiation monitoring stations to a centralized system for radioprotection data. For this is used the File Transfer Protocol (FTP). A Radiation Monitoring Equipment designed and assembled in the Electronics Department of ICN Pitesti was used as a data source for the testing of the experimental programs. (authors)

  20. Ultra-compact swept-source optical coherence tomography handheld probe with motorized focus adjustment (Conference Presentation)

    Science.gov (United States)

    LaRocca, Francesco; Nankivil, Derek; Keller, Brenton; Farsiu, Sina; Izatt, Joseph A.

    2017-02-01

    Handheld optical coherence tomography (OCT) systems facilitate imaging of young children, bedridden subjects, and those with less stable fixation. Smaller and lighter OCT probes allow for more efficient imaging and reduced operator fatigue, which is critical for prolonged use in either the operating room or neonatal intensive care unit. In addition to size and weight, the imaging speed, image quality, field of view, resolution, and focus correction capability are critical parameters that determine the clinical utility of a handheld probe. Here, we describe an ultra-compact swept source (SS) OCT handheld probe weighing only 211 g (half the weight of the next lightest handheld SSOCT probe in the literature) with 20.1 µm lateral resolution, 7 µm axial resolution, 102 dB peak sensitivity, a 27° x 23° field of view, and motorized focus adjustment for refraction correction between -10 to +16 D. A 2D microelectromechanical systems (MEMS) scanner, a converging beam-at-scanner telescope configuration, and an optical design employing 6 different custom optics were used to minimize device size and weight while achieving diffraction limited performance throughout the system's field of view. Custom graphics processing unit (GPU)-accelerated software was used to provide real-time display of OCT B-scans and volumes. Retinal images were acquired from adult volunteers to demonstrate imaging performance.

  1. Computerized Proof Techniques for Undergraduates

    Science.gov (United States)

    Smith, Christopher J.; Tefera, Akalu; Zeleke, Aklilu

    2012-01-01

    The use of computer algebra systems such as Maple and Mathematica is becoming increasingly important and widespread in mathematics learning, teaching and research. In this article, we present computerized proof techniques of Gosper, Wilf-Zeilberger and Zeilberger that can be used for enhancing the teaching and learning of topics in discrete…

  2. SAFARI 2000 Atmospheric Aerosol Measurements, Hand-held Hazemeters, Zambia

    Data.gov (United States)

    National Aeronautics and Space Administration — In conjunction with the AERONET (AErosol RObotic NETwork) participation in SAFARI 2000, the USDA Forest Service deployed handheld hazemeters in western Zambia from...

  3. Handheld FRET-Aptamer Sensor for Water Safety, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Operational Technologies Corporation (OpTech) proposes to expand its current NASA Phase 2 SBIR handheld fluorometer and bone marker fluorescence resonance energy...

  4. The availability of relatively cheap hand-held Global Positioning ...

    African Journals Online (AJOL)

    spamer

    conditions, so the approach failed to produce results ... Hand-held Global Positioning System (GPS) receivers provide opportunities for detailed and rapid mapping of features ..... TICKELL, W. L. N. 1968 — The biology of the great albatrosses,.

  5. An Intelligent Hand-Held Microsurgical Instrument for Improved Accuracy

    National Research Council Canada - National Science Library

    Ang, Wei

    2001-01-01

    This paper presents the development and initial experimental results of the first prototype of Micron, an active hand-held instrument to sense and compensate physiological tremor and other unwanted...

  6. Computerized adaptive testing in computer assisted learning?

    NARCIS (Netherlands)

    Veldkamp, Bernard P.; Matteucci, Mariagiulia; Eggen, Theodorus Johannes Hendrikus Maria; De Wannemacker, Stefan; Clarebout, Geraldine; De Causmaecker, Patrick

    2011-01-01

    A major goal in computerized learning systems is to optimize learning, while in computerized adaptive tests (CAT) efficient measurement of the proficiency of students is the main focus. There seems to be a common interest to integrate computerized adaptive item selection in learning systems and

  7. Introduction of handheld computing to a family practice residency program.

    Science.gov (United States)

    Rao, Goutham

    2002-01-01

    Handheld computers are valuable practice tools. It is important for residency programs to introduce their trainees and faculty to this technology. This article describes a formal strategy to introduce handheld computing to a family practice residency program. Objectives were selected for the handheld computer training program that reflected skills physicians would find useful in practice. TRGpro handheld computers preloaded with a suite of medical reference programs, a medical calculator, and a database program were supplied to participants. Training consisted of four 1-hour modules each with a written evaluation quiz. Participants completed a self-assessment questionnaire after the program to determine their ability to meet each objective. Sixty of the 62 participants successfully completed the training program. The mean composite score on quizzes was 36 of 40 (90%), with no significant differences by level of residency training. The mean self-ratings of participants across all objectives was 3.31 of 4.00. Third-year residents had higher mean self-ratings than others (mean of group, 3.62). Participants were very comfortable with practical skills, such as using drug reference software, and less comfortable with theory, such as knowing the different types of handheld computers available. Structured training is a successful strategy for introducing handheld computing to a residency program.

  8. A review of the use of handheld computers in medical nutrition.

    Science.gov (United States)

    Holubar, Stefan; Harvey-Banchik, Lillian

    2007-08-01

    Handheld computers, or personal digital assistants (PDAs), have been used to assist clinicians in medical nutrition since the early 1980s. The term PDA was originally applied to programmable calculators; over time, the capabilities of these devices were expanded to allow for the use of more complicated programs such as databases, spreadsheets, and electronic books. Slowly, the device evolved into what is more commonly thought of as a PDA, that is, a device such as a PalmOS (PalmSource, Inc, Tokyo, Japan) or PocketPC (Microsoft, Redmond, WA) unit. We present a review of the literature about the use of PDAs in medical nutrition, followed by a discussion of the different types of PDAs and mobile technologies that are commercially available. This is followed by a discussion of software applications that are currently available for use by nutrition clinicians, focusing on freeware applications. Finally, future technologies and applications are discussed.

  9. Introducing Handheld Computing for Interactive Medical Education

    Directory of Open Access Journals (Sweden)

    Joseph Finkelstein

    2005-04-01

    Full Text Available The goals of this project were: (1 development of an interactive multimedia medical education tool (CO-ED utilizing modern features of handheld computing (PDA and major constructs of adult learning theories, and (2 pilot testing of the computer-assisted education in residents and clinicians. Comparison of the knowledge scores using paired t-test demonstrated statistically significant increase in subject knowledge (p<0.01 after using CO-ED. Attitudinal surveys were analyzed by total score (TS calculation represented as a percentage of a maximal possible score. The mean TS was 74.5±7.1%. None of the subjects (N=10 had TS less than 65% and in half of the subjects (N=5 TS was higher than 75%. Analysis of the semi-structured in-depth interviews showed strong support of the study subjects in using PDA as an educational tool, and high acceptance of CO-ED user interface. We concluded that PDA have a significant potential as a tool for clinician education.

  10. Hand-held optical fuel pin scanner

    International Nuclear Information System (INIS)

    Kirchner, T.L.; Powers, H.G.

    1987-01-01

    A portable, hand-held apparatus is described for optically scanning indicia imprinted about a planar end face of an article having an outer wall surface, the apparatus comprising: a supporting frame; light detector means fixed to the frame for digitizing light patterns directed thereto; indexing means on the frame for engaging the planar end face and locating the end face in a preselected focal plane on the frame. The indexing means has an inner wall surface complementary to the article wall surface for disposition thereabout and terminates in an end portion beyond the planar end face. The inner wall surface has a radially inwardly extending shoulder spaced from the end portion and engageable with the planar end face; light means directed onto the preselected focal plane; optical means mounted on the frame about a central axis, the optical means being optically interposed between the indexing means and the light detector means for directing reflected light from the preselected focal plane to the light detector means and including a dove prism centrally aligned along the central axis; and means for selectively rotating the dove prism relative to the frame about the central axis to thereby rotate the image from the focal plane as transmitted to the light detector means

  11. E-book Trial Using Handheld Devices Yields Mixed Reactions from Public Library Staff and Users in Essex County, UK. A review of: Dearnley, James, Cliff McKnight, and Anne Morris. “Electronic Book Usage in Public Libraries: A Study of User and Staff Reactions to a PDA-based Collection.” Journal of Librarianship and Information Science 36.4 (December 2004: 175‐82.

    Directory of Open Access Journals (Sweden)

    Stephanie Hall

    2006-03-01

    Full Text Available Objective - To assess e-book delivery on handheld devices provided to public library patrons, particularly housebound or visually impaired patrons and the users of a mobile library. Design - Product trial with a post-trial questionnaire for patrons and a post-trial focus group discussion among participating library staff. Setting - Mid-to-large size public library system in the United Kingdom. Subjects - 23 patrons participated; the number of library staff participating is not identified. Although the target population initially identified was housebound people, patrons reliant on the mobile library, and visually impaired people, the project team determined that it did not have sufficient funds to upgrade the PDAs to be compatible woth their preferred software for the visually impaired, and therefore this group was eliminated from the study. Lack of funds was also cited as a factor in the team being unable to provide assistive technology for those users suffering from arthritis, though this group was not excluded from the study. Just over half the patrons were aged 60+, and more than half were female. Two patrons self-identified as housebound. Methods - e-books were downloaded onto Hewlett Packard iPAQ 1910 Pdas by library staff and were loaned to participants between Janualry and April 2004. Although the authors of the study state that "creating staff champions was an important objective in this project" (p.176, it is unclear whether staff were screened for positive attitude towards e-Books. Prior to the trial, staff members were provided with training and orientation, and participants were asked for their font sna d reading preferences. Suport for participating patrons was available from staff or via an accompanying user manual, e-mail, or telephone help line. In a questionnaire adminsitered following the trial, participants were asked to respond to questions on the functionality of the handheld devices and e-book formats, positive and

  12. Mobile Learning Devices. Essentials for Principals

    Science.gov (United States)

    Rogers, Kipp D.

    2011-01-01

    In "Mobile Learning Devices," the author helps educators confront and overcome their fears and doubts about using mobile learning devices (MLDs) such as cell phones, personal digital assistants, MP3 players, handheld games, digital audio players, and laptops in classrooms. School policies that ban such tools are outdated, the author suggests;…

  13. Computerized ECT data analysis system

    International Nuclear Information System (INIS)

    Miyake, Y.; Fukui, S.; Iwahashi, Y.; Matsumoto, M.; Koyama, K.

    1988-01-01

    For the analytical method of the eddy current testing (ECT) of steam generator tubes in nuclear power plants, the authors have developed the computerized ECT data analysis system using a large-scale computer with a high-resolution color graphic display. This system can store acquired ECT data up to 15 steam generators, and ECT data can be analyzed immediately on the monitor in dialogue communication with a computer. Analyzed results of ECT data are stored and registered in the data base. This system enables an analyst to perform sorting and collecting of data under various conditions and obtain the results automatically, and also to make a plan of tube repair works. This system has completed the test run, and has been used for data analysis at the annual inspection of domestic plants. This paper describes an outline, features and examples of the computerized eddy current data analysis system for steam generator tubes in PWR nuclear power plants

  14. Quantitative inspection by computerized tomography

    International Nuclear Information System (INIS)

    Lopes, R.T.; Assis, J.T. de; Jesus, E.F.O. de

    1989-01-01

    The computerized Tomography (CT) is a method of nondestructive testing, that furnish quantitative information, that permit the detection and accurate localization of defects, internal dimension measurement, and, measurement and chart of the density distribution. The CT technology is much versatile, not presenting restriction in relation to form, size or composition of the object. A tomographic system, projected and constructed in our laboratory is presented. The applications and limitation of this system, illustrated by tomographyc images, are shown. (V.R.B.)

  15. Handheld pose tracking using vision-inertial sensors with occlusion handling

    Science.gov (United States)

    Li, Juan; Slembrouck, Maarten; Deboeverie, Francis; Bernardos, Ana M.; Besada, Juan A.; Veelaert, Peter; Aghajan, Hamid; Casar, José R.; Philips, Wilfried

    2016-07-01

    Tracking of a handheld device's three-dimensional (3-D) position and orientation is fundamental to various application domains, including augmented reality (AR), virtual reality, and interaction in smart spaces. Existing systems still offer limited performance in terms of accuracy, robustness, computational cost, and ease of deployment. We present a low-cost, accurate, and robust system for handheld pose tracking using fused vision and inertial data. The integration of measurements from embedded accelerometers reduces the number of unknown parameters in the six-degree-of-freedom pose calculation. The proposed system requires two light-emitting diode (LED) markers to be attached to the device, which are tracked by external cameras through a robust algorithm against illumination changes. Three data fusion methods have been proposed, including the triangulation-based stereo-vision system, constraint-based stereo-vision system with occlusion handling, and triangulation-based multivision system. Real-time demonstrations of the proposed system applied to AR and 3-D gaming are also included. The accuracy assessment of the proposed system is carried out by comparing with the data generated by the state-of-the-art commercial motion tracking system OptiTrack. Experimental results show that the proposed system has achieved high accuracy of few centimeters in position estimation and few degrees in orientation estimation.

  16. A handheld point-of-care genomic diagnostic system.

    Directory of Open Access Journals (Sweden)

    Frank B Myers

    Full Text Available The rapid detection and identification of infectious disease pathogens is a critical need for healthcare in both developed and developing countries. As we gain more insight into the genomic basis of pathogen infectivity and drug resistance, point-of-care nucleic acid testing will likely become an important tool for global health. In this paper, we present an inexpensive, handheld, battery-powered instrument designed to enable pathogen genotyping in the developing world. Our Microfluidic Biomolecular Amplification Reader (µBAR represents the convergence of molecular biology, microfluidics, optics, and electronics technology. The µBAR is capable of carrying out isothermal nucleic acid amplification assays with real-time fluorescence readout at a fraction of the cost of conventional benchtop thermocyclers. Additionally, the µBAR features cell phone data connectivity and GPS sample geotagging which can enable epidemiological surveying and remote healthcare delivery. The µBAR controls assay temperature through an integrated resistive heater and monitors real-time fluorescence signals from 60 individual reaction chambers using LEDs and phototransistors. Assays are carried out on PDMS disposable microfluidic cartridges which require no external power for sample loading. We characterize the fluorescence detection limits, heater uniformity, and battery life of the instrument. As a proof-of-principle, we demonstrate the detection of the HIV-1 integrase gene with the µBAR using the Loop-Mediated Isothermal Amplification (LAMP assay. Although we focus on the detection of purified DNA here, LAMP has previously been demonstrated with a range of clinical samples, and our eventual goal is to develop a microfluidic device which includes on-chip sample preparation from raw samples. The µBAR is based entirely around open source hardware and software, and in the accompanying online supplement we present a full set of schematics, bill of materials, PCB layouts

  17. Computerized accounting methods. Final report

    International Nuclear Information System (INIS)

    1994-01-01

    This report summarizes the results of the research performed under the Task Order on computerized accounting methods in a period from 03 August to 31 December 1994. Computerized nuclear material accounting methods are analyzed and evaluated. Selected methods are implemented in a hardware-software complex developed as a prototype of the local network-based CONMIT system. This complex has been put into trial operation for test and evaluation of the selected methods at two selected ''Kurchatov Institute'' Russian Research Center (''KI'' RRC) nuclear facilities. Trial operation is carried out since the beginning of Initial Physical Inventory Taking in these facilities that was performed in November 1994. Operation of CONMIT prototype system was demonstrated in the middle of December 1994. Results of evaluation of CONMIT prototype system features and functioning under real operating conditions are considered. Conclusions are formulated on the ways of further development of computerized nuclear material accounting methods. The most important conclusion is a need to strengthen computer and information security features supported by the operating environment. Security provisions as well as other LANL Client/Server System approaches being developed by Los Alamos National Laboratory are recommended for selection of software and hardware components to be integrated into production version of CONMIT system for KI RRC

  18. Effects of a Driver Cellphone Ban on Overall, Handheld, and Hands-Free Cellphone Use While Driving: New Evidence from Canada.

    Science.gov (United States)

    Carpenter, Christopher S; Nguyen, Hai V

    2015-11-01

    We provide new evidence on the effects of increasingly common driver cellphone bans on self-reported overall, handheld, and hands-free cellphone use while driving by studying Ontario, Canada, which instituted a 3-month education campaign in November 2009 followed by a binding driver cellphone ban in February 2010. Using residents of Alberta as a control group in a difference-in-differences framework, we find visual and regression-based evidence that Ontario's cellphone ban significantly reduced overall and handheld cellphone use. We also find that the policies significantly increased hands-free cellphone use. The reductions in overall and handheld use are driven exclusively by women, whereas the increases in hands-free use are much larger for men. Our results provide the first direct evidence that cellphone bans have the unintended effect of inducing substitution to hands-free devices. Copyright © 2014 John Wiley & Sons, Ltd.

  19. Applicability of a Diffuse Reflectance Infrared Fourier Transform handheld spectrometer to perform in situ analyses on Cultural Heritage materials.

    Science.gov (United States)

    Arrizabalaga, Iker; Gómez-Laserna, Olivia; Aramendia, Julene; Arana, Gorka; Madariaga, Juan Manuel

    2014-08-14

    This work studies the applicability of a Diffuse Reflectance Infrared Fourier Transform handheld device to perform in situ analyses on Cultural Heritage assets. This portable diffuse reflectance spectrometer has been used to characterise and diagnose the conservation state of (a) building materials of the Guevara Palace (15th century, Segura, Basque Country, Spain) and (b) different 19th century wallpapers manufactured by the Santa Isabel factory (Vitoria-Gasteiz, Basque Country, Spain) and by the well known Dufour and Leroy manufacturers (Paris, France), all of them belonging to the Torre de los Varona Castle (Villanañe, Basque Country, Spain). In all cases, in situ measurements were carried out and also a few samples were collected and measured in the laboratory by diffuse reflectance spectroscopy (DRIFT) in order to validate the information obtained by the handheld instrument. In the analyses performed in situ, distortions in the diffuse reflectance spectra can be observed due to the presence of specular reflection, showing the inverted bands caused by the Reststrahlen effect, in particular on those IR bands with the highest absorption coefficients. This paper concludes that the results obtained in situ by a diffuse reflectance handheld device are comparable to those obtained with laboratory diffuse reflectance spectroscopy equipment and proposes a few guidelines to acquire good spectra in the field, minimising the influence caused by the specular reflection. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Decisions at hand: a decision support system on handhelds.

    Science.gov (United States)

    Zupan, B; Porenta, A; Vidmar, G; Aoki, N; Bratko, I; Beck, J R

    2001-01-01

    One of the applications of clinical information systems is decision support. Although the advantages of utilizing such aids have never been theoretically disputed, they have been rarely used in practice. The factor that probably often limits the utility of clinical decision support systems is the need for computing power at the very site of decision making--at the place where the patient is interviewed, in discussion rooms, etc. The paper reports on a possible solution to this problem. A decision-support shell LogReg is presented, which runs on a handheld computer. A general schema for handheld-based decision support is also proposed, where decision models are developed on personal computers/workstations, encoded in XML and then transferred to handhelds, where the models are used within a decision support shell. A use case where LogReg has been applied to clinical outcome prediction in crush injury is presented.

  1. Computerized tomography of orbital lesions

    International Nuclear Information System (INIS)

    Kuroiwa, Mayumi

    1981-01-01

    Two different types of computerized tomography scanners (CT scanner), i.e. a whole-body CT scanner (GE-CT/T8800) and a cerebral CT scanner (EMI-1010), were compared in the assessment and diagnosis of various orbital lesions. The whole-body CT scanner was found to be advantageous over the cerebral CT scanner for the following reasons: (1) CT images were more informative due to thinner slices associated with smaller-sized and larger-numbered matrices; (2) less artifacts derived from motion of the head or eyeball were produced because of the shorter scanning time; (3) with a devised gantry, coronal dissections were available whenever demanded. (author)

  2. Bring Your Own Device to Language Class--Applying Handheld Devices in Classroom Learning

    Science.gov (United States)

    Talmo, Tord; Einum, Even; Støckert, Robin

    2014-01-01

    Language students often struggle to understand the logic in foreign language grammar, reducing their ability to reproduce and create texts on their own. There are several reasons for this; everything from the methodology to lack of motivation might influence the situation. Since the 1980's, Computer Assisted Language Learning (CALL) has become one…

  3. Investigating Cross-Device Interaction between a Handheld Device and a Large Display

    DEFF Research Database (Denmark)

    Paay, Jeni; Raptis, Dimitrios; Kjeldskov, Jesper

    2017-01-01

    and mid-air gestures, pinching, swiping, swinging and flicking. We look specifically at their relative efficiency, effectiveness and accuracy in bi-directional interaction between a smartphone and large display in a point-click context. We report findings from two user studies, which show that swiping...... is both most effective, fastest and most accurate, closely followed by swinging. What these two approaches have in common is the ability to keep the pointer steady on the large display, unaffected by concurrent gestures or body movements used to complete the interaction, suggesting...

  4. DOE transporation programs - computerized techniques

    Energy Technology Data Exchange (ETDEWEB)

    Joy, D.S.; Johnson, P.E.; Fore, C.S.; Peterson, B.E.

    1983-01-01

    One of the major thrusts of the transportation programs at the Oak Ridge National Laboratory has been the development of a number of computerized transportation programs and data bases. The U.S. Department of Energy (DOE) is supporting these efforts through the Transportation Technology Center at Sandia National Laboratories and the Tranportation Operations and Traffic Management (TOTM) organization at DOE Headquarters. Initially this project was centered upon research activities. However, since these tools provide traffic managers and key personnel involved in preshipment planning with a unique resource for ensuring that the movement of radioactive materials can be properly accomplished, additional interest and support is coming from the operational side of DOE. The major accomplishments include the development of two routing models (one for rail shipments and the other for highway shipments), an emergency response assistance program, and two data bases containing pertinent legislative and regulatory information. This paper discusses the mose recent advances in, and additions to, these computerized techniques and provides examples of how they are used.

  5. Computerized index for teaching files

    International Nuclear Information System (INIS)

    Bramble, J.M.

    1989-01-01

    A computerized index can be used to retrieve cases from a teaching file that have radiographic findings similar to an unknown case. The probability that a user will review cases with a correct diagnosis was estimated with use of radiographic findings of arthritis in hand radiographs of 110 cases from a teaching file. The nearest-neighbor classification algorithm was used as a computer index to 110 cases of arthritis. Each case was treated as an unknown and inputted to the computer index. The accuracy of the computer index in retrieving cases with the same diagnosis (including rheumatoid arthritis, gout, psoriatic arthritis, inflammatory osteoarthritis, and pyrophosphate arthropathy) was measured. A Bayes classifier algorithm was also tested on the same database. Results are presented. The nearest-neighbor algorithm was 83%. By comparison, the estimated accuracy of the Bayes classifier algorithm was 78%. Conclusions: A computerized index to a teaching file based on the nearest-neighbor algorithm should allow the user to review cases with the correct diagnosis of an unknown case, by entering the findings of the unknown case

  6. A handheld open-field infant keratometer (an american ophthalmological society thesis).

    Science.gov (United States)

    Miller, Joseph M

    2010-12-01

    To design and evaluate a new infant keratometer that incorporates an unobstructed view of the infant with both eyes (open-field design). The design of the open-field infant keratometer is presented, and details of its construction are given. The design incorporates a single-ring keratoscope for measurement of corneal astigmatism over a 4-mm region of the cornea and includes a rectangular grid target concentric within the ring to allow for the study of higher-order aberrations of the eye. In order to calibrate the lens and imaging system, a novel telecentric test object was constructed and used. The system was bench calibrated against steel ball bearings of known dimensions and evaluated for accuracy while being used in handheld mode in a group of 16 adult cooperative subjects. It was then evaluated for testability in a group of 10 infants and toddlers. Results indicate that while the device achieved the goal of creating an open-field instrument containing a single-ring keratoscope with a concentric grid array for the study of higher-order aberrations, additional work is required to establish better control of the vertex distance. The handheld open-field infant keratometer demonstrates testability suitable for the study of infant corneal astigmatism. Use of collimated light sources in future iterations of the design must be incorporated in order to achieve the accuracy required for clinical investigation.

  7. Advanced sampling techniques for hand-held FT-IR instrumentation

    Science.gov (United States)

    Arnó, Josep; Frunzi, Michael; Weber, Chris; Levy, Dustin

    2013-05-01

    FT-IR spectroscopy is the technology of choice to identify solid and liquid phase unknown samples. The challenging ConOps in emergency response and military field applications require a significant redesign of the stationary FT-IR bench-top instruments typically used in laboratories. Specifically, field portable units require high levels of resistance against mechanical shock and chemical attack, ease of use in restrictive gear, extreme reliability, quick and easy interpretation of results, and reduced size. In the last 20 years, FT-IR instruments have been re-engineered to fit in small suitcases for field portable use and recently further miniaturized for handheld operation. This article introduces the HazMatID™ Elite, a FT-IR instrument designed to balance the portability advantages of a handheld device with the performance challenges associated with miniaturization. In this paper, special focus will be given to the HazMatID Elite's sampling interfaces optimized to collect and interrogate different types of samples: accumulated material using the on-board ATR press, dispersed powders using the ClearSampler™ tool, and the touch-to-sample sensor for direct liquid sampling. The application of the novel sample swipe accessory (ClearSampler) to collect material from surfaces will be discussed in some detail. The accessory was tested and evaluated for the detection of explosive residues before and after detonation. Experimental results derived from these investigations will be described in an effort to outline the advantages of this technology over existing sampling methods.

  8. Computerized Classification Testing with the Rasch Model

    Science.gov (United States)

    Eggen, Theo J. H. M.

    2011-01-01

    If classification in a limited number of categories is the purpose of testing, computerized adaptive tests (CATs) with algorithms based on sequential statistical testing perform better than estimation-based CATs (e.g., Eggen & Straetmans, 2000). In these computerized classification tests (CCTs), the Sequential Probability Ratio Test (SPRT) (Wald,…

  9. Accuracy of Handheld Blood Glucose Meters at High Altitude

    NARCIS (Netherlands)

    de Mol, Pieter; Krabbe, Hans G.; de Vries, Suzanna T.; Fokkert, Marion J.; Dikkeschei, Bert D.; Rienks, Rienk; Bilo, Karin M.; Bilo, Henk J. G.

    2010-01-01

    Background: Due to increasing numbers of people with diabetes taking part in extreme sports (e. g., high-altitude trekking), reliable handheld blood glucose meters (BGMs) are necessary. Accurate blood glucose measurement under extreme conditions is paramount for safe recreation at altitude. Prior

  10. Monitoring invasive plants using hand-held GIS technology

    Science.gov (United States)

    Theresa M. Mau-Crimmins; Barron J. Orr

    2005-01-01

    Successful control of invasive species requires a clear picture of the spatial extent of infestations. The latest mapping technology involves coupling global position systems and handheld computers running geographic information systems software in the field. A series of workshops applying this technology to mapping weeds was developed and presented to Weed Management...

  11. Exploring streamwater mixing dynamics via handheld thermal infrared imagery

    NARCIS (Netherlands)

    Antonelli, Marta; Klaus, Julian; Smettem, Keith; Teuling, Ryan; Pfister, Laurent

    2017-01-01

    Stream confluences are important hotspots of aquatic ecological processes. Water mixing dynamics at stream confluences influence physio-chemical characteristics of the stream as well as sediment mobilisation and pollutant dispersal. In this study, we investigated the potential for handheld

  12. Neurosurgery contact handheld probe based on sapphire shaped crystal

    Science.gov (United States)

    Shikunova, I. A.; Stryukov, D. O.; Rossolenko, S. N.; Kiselev, A. M.; Kurlov, V. N.

    2017-01-01

    A handheld contact probe based on sapphire shaped crystal is developed for intraoperative spectrally-resolved optical diagnostics, laser coagulation and aspiration of malignant brain tissue. The technology was integrated into the neurosurgical workflow for intraoperative real-time identification and removing of invasive brain cancer.

  13. Octopus: embracing the energy efficiency of handheld multimedia computers

    NARCIS (Netherlands)

    Havinga, Paul J.M.; Smit, Gerardus Johannes Maria

    1999-01-01

    In the MOBY DICK project we develop and define the architecture of a new generation of mobile hand-held computers called Mobile Digital Companions. The Companions must meet several major requirements: high performance, energy efficient, a notion of Quality of Service (QoS), small size, and low

  14. Imaging Emission Spectra with Handheld and Cellphone Cameras

    Science.gov (United States)

    Sitar, David

    2012-01-01

    As point-and-shoot digital camera technology advances it is becoming easier to image spectra in a laboratory setting on a shoestring budget and get immediate results. With this in mind, I wanted to test three cameras to see how their results would differ. Two undergraduate physics students and I used one handheld 7.1 megapixel (MP) digital Cannon…

  15. Data for Users of Handheld Ion Mobility Spectrometers

    International Nuclear Information System (INIS)

    Keith A. Daum; Sandra L. Fox

    2008-01-01

    Chemical detection technology end-user surveys conducted by Idaho National Laboratory (INL) in 2005 and 2007 indicated that first responders believed manufacturers claims for instruments sometimes were not supported in field applications, and instruments sometimes did not meet their actual needs. Based on these findings, the Department of Homeland Security (DHS) asked INL to conduct a similar survey for handheld ion mobility spectrometers (IMS), which are used by a broad community of first responders as well as for other applications. To better access this broad community, the INL used the Center for Technology Commercialization, Inc. (CTC), Public Safety Technology Center (PSTC) to set up an online framework to gather information from users of handheld IMS units. This framework (Survey Monkey) was then used to perform an online Internet survey, augmented by e-mail prompts, to get information from first responders and personnel from various agencies about their direct experience with handheld IMS units. Overall, 478 individuals responded to the survey. Of these, 174 respondents actually owned a handheld IMS. Performance and satisfaction data from these 174 respondents are captured in this report. The survey identified the following observations: (1) The most common IMS unit used by respondents was the Advanced Portable Detector (APD 2000), followed by ChemRae, Sabre 4000, Sabre 2000, Draeger Multi IMS, Chemical Agent Monitor-2, Chemical Agent Monitor, Vapor Tracer, and Vapor Tracer 2. (2) The primary owners were HazMat teams (20%), fire services (14%), local police (12%), and sheriffs departments (9%). (3) IMS units are seldom used as part of an integrated system for detecting and identifying chemicals but instead are used independently. (4) Respondents are generally confused about the capabilities of their IMS unit. This is probably a result of lack of training. (5) Respondents who had no training or fewer than 8 hours were not satisfied with the overall operation

  16. Computerized portable microwave hyperthermia quality assurance kit

    International Nuclear Information System (INIS)

    Cheung, A.Y.; Neyzari, A.

    1985-01-01

    A computerized quality assurance kit to provide precise measurement and calibration of microwave power and temperature, as well as capabilities to map SAR (Specific absorption rate) distribution in phantoms; and survey of hazardous microwave leakage has been designed. The kit is also capable of performing corelation studies on the relationship between SAR and net microwave power delivered at various anatomical sites. The kit consists of a portable microcomputer, a time-multiplexed A/D converter, a 4-channel dual directional microwave power monitor, a 4-channel thin-wire thermocouple thermometry system, an electronic thermal calibrator, a microwave leakage hazard survey meter, and a dynamic phantom tank for dosimetric analysis. Comparative performance studies were made against NBS-traceable power and temperature standards, non-perturbing optical temperature sensors, and established power and temperature measurement devices. The test results indicate that this instrument is providing its user with measurement accuracy of 0.1 0 C in temperature, 10% accuracy in power. The thin-wire thermocouple, with computer assisted error compensation, performs equally well in a strong microwave field in comparison with non-perturbing optical temperature sensors

  17. 78 FR 43262 - Use of Wireless Mobile Data Devices as Transponders for the Commercial Motor Vehicle Information...

    Science.gov (United States)

    2013-07-19

    ... FMCSA's regulations prohibiting texting and the use of hand-held wireless mobile phones by commercial... part 392 prohibiting texting and the use of hand-held wireless mobile phones by commercial motor vehicle (CMV) drivers. Benefits Use of wireless mobile data devices as transponders with CMRS provides...

  18. Computerized tomography of the mandibular joints and masticatory muscles

    International Nuclear Information System (INIS)

    Huels, A.B.

    1981-01-01

    A methodology for computerized tomography of the mandibular joints was developed and applied in 80 test persons. Imaging of the mandibular joints is possible with a tomographic technique with 5 mm-overlap, full utilisation of the enlargement capacity of the imaging device, and combined use of transversal and coronary tomography. The method yields full latero-medial, cranio-caudal and anterior-posterior views of the condyle and fossa contours, free of interferences and of distortions caused by the projection. Positional diagnoses are thus possible as well as diagnoses of pathological structural changes. (orig./MG) [de

  19. Psychometrics behind Computerized Adaptive Testing.

    Science.gov (United States)

    Chang, Hua-Hua

    2015-03-01

    The paper provides a survey of 18 years' progress that my colleagues, students (both former and current) and I made in a prominent research area in Psychometrics-Computerized Adaptive Testing (CAT). We start with a historical review of the establishment of a large sample foundation for CAT. It is worth noting that the asymptotic results were derived under the framework of Martingale Theory, a very theoretical perspective of Probability Theory, which may seem unrelated to educational and psychological testing. In addition, we address a number of issues that emerged from large scale implementation and show that how theoretical works can be helpful to solve the problems. Finally, we propose that CAT technology can be very useful to support individualized instruction on a mass scale. We show that even paper and pencil based tests can be made adaptive to support classroom teaching.

  20. Chinese computerized nuclear data library

    International Nuclear Information System (INIS)

    Liang Qichang; Cai Dunjiu

    1996-01-01

    The Second Version of Chinese Evaluated Nuclear Data Library (CENDL-2) includes the complete neutron nuclear data sets of 54 important elements and isotopes used for nuclear science and engineering with the incident neutron energy from 10 -5 eV to 20 MeV, the international universal format ENDF/B-6 was adopted. Now, the Chinese Computerized nuclear data library has been developed and put into operation. That is, the users can make on-line use of the main data libraries for evaluated neutron reaction data in the world of EXFOR experimental nuclear data library on the terminal of computer via the perfect computer software system, carry out directly the nuclear engineering calculation or nuclear data evaluation, enjoy the use of the resource of our nuclear data libraries for their development of nuclear energy and nuclear technology applications

  1. Computerized evaluation of flood impact

    International Nuclear Information System (INIS)

    Gagnon, J.; Quach, T.T.; Marche, C.; Lessard, G.

    1998-01-01

    A computerized evaluation process for assessing the economic impacts of a potential dam failure is described. The DOMINO software, which was developed by Hydro-Quebec, takes into account flow data from dam break simulations of floods, the territory involved, plus the economic evaluations of the real estate and infrastructures affected. Some examples of software applications and impact evaluations are presented. The principal elements involved in estimating economic or other types of impacts induced by natural flooding or dam failure, are: (1) flow forecasting, (2) defining the contour of the involved territory, and (3) accounting for the various impacts identified in the affected zone. Owing to its wide range of functions and utilities, DOMINO has proven to be a very useful, user-friendly and portable decision-making tool. 5 refs., 6 tabs

  2. Using mobile and web-based computerized tests to evaluate university students

    NARCIS (Netherlands)

    Romero, C.; Ventura, S.; De Bra, P.M.E.

    2009-01-01

    Mobile learning and testing is emerging as a potential educational environment. In this article we evaluate the use of mobile devices for testing as compared to web-based assessment systems. We also describe an authoring tool to develop adaptable and adaptive computerized tests that can be executed

  3. Hand-held dynamic visual noise reduces naturally occurring food cravings and craving-related consumption.

    Science.gov (United States)

    Kemps, Eva; Tiggemann, Marika

    2013-09-01

    This study demonstrated the applicability of the well-established laboratory task, dynamic visual noise, as a technique for reducing naturally occurring food cravings and subsequent food intake. Dynamic visual noise was delivered on a hand-held computer device. Its effects were assessed within the context of a diary study. Over a 4-week period, 48 undergraduate women recorded their food cravings and consumption. Following a 2-week baseline, half the participants watched the dynamic visual noise display whenever they experienced a food craving. Compared to a control group, these participants reported less intense cravings. They were also less likely to eat following a craving and consequently consumed fewer total calories following craving. These findings hold promise for curbing unwanted food cravings and craving-driven consumption in real-world settings. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. A hand-held 3D laser scanning with global positioning system of subvoxel precision

    International Nuclear Information System (INIS)

    Arias, Nestor; Meneses, Nestor; Meneses, Jaime; Gharbi, Tijani

    2011-01-01

    In this paper we propose a hand-held 3D laser scanner composed of an optical head device to extract 3D local surface information and a stereo vision system with subvoxel precision to measure the position and orientation of the 3D optical head. The optical head is manually scanned over the surface object by the operator. The orientation and position of the 3D optical head is determined by a phase-sensitive method using a 2D regular intensity pattern. This phase reference pattern is rigidly fixed to the optical head and allows their 3D location with subvoxel precision in the observation field of the stereo vision system. The 3D resolution achieved by the stereo vision system is about 33 microns at 1.8 m with an observation field of 60cm x 60cm.

  5. Development of a Handheld Line Information Reader and Generator for Efficient Management of Optical Communication Lines.

    Science.gov (United States)

    Lee, Jaeyul; Kwon, Hyungwoo; Song, Jaewon; Jeon, Mansik; Kim, Jeehyun

    2017-08-24

    A handheld line information reader and a line information generator were developed for the efficient management of optical communication lines. The line information reader consists of a photo diode, trans-impedance amplifier, voltage amplifier, microcontroller unit, display panel, and communication modules. The line information generator consists of a laser diode, laser driving circuits, microcontroller unit, and communication modules. The line information reader can detect the optical radiation field of the test line by bending the optical fiber. To enhance the sensitivity of the line information reader, an additional lens was used with a focal length of 4.51 mm. Moreover, the simulation results obtained through BeamPROP ® software from Synopsys, Inc. demonstrated a stronger optical radiation field of the fiber due to a longer transmission wavelength and larger bending angle of the fiber. Therefore, the developed devices can be considered as useful tools for the efficient management of optical communication lines.

  6. Improving energy efficiency in handheld biometric applications

    Science.gov (United States)

    Hoyle, David C.; Gale, John W.; Schultz, Robert C.; Rakvic, Ryan N.; Ives, Robert W.

    2012-06-01

    With improved smartphone and tablet technology, it is becoming increasingly feasible to implement powerful biometric recognition algorithms on portable devices. Typical iris recognition algorithms, such as Ridge Energy Direction (RED), utilize two-dimensional convolution in their implementation. This paper explores the energy consumption implications of 12 different methods of implementing two-dimensional convolution on a portable device. Typically, convolution is implemented using floating point operations. If a given algorithm implemented integer convolution vice floating point convolution, it could drastically reduce the energy consumed by the processor. The 12 methods compared include 4 major categories: Integer C, Integer Java, Floating Point C, and Floating Point Java. Each major category is further divided into 3 implementations: variable size looped convolution, static size looped convolution, and unrolled looped convolution. All testing was performed using the HTC Thunderbolt with energy measured directly using a Tektronix TDS5104B Digital Phosphor oscilloscope. Results indicate that energy savings as high as 75% are possible by using Integer C versus Floating Point C. Considering the relative proportion of processing time that convolution is responsible for in a typical algorithm, the savings in energy would likely result in significantly greater time between battery charges.

  7. [Computerized medical record: deontology and legislation].

    Science.gov (United States)

    Allaert, F A; Dusserre, L

    1996-02-01

    Computerization of medical records is making headway for patients' follow-up, scientific research, and health expenses control, but it must not alter the guarantees provided to the patients by the medical code of ethics and the law of January 6, 1978. This law, modified on July 1, 1994, requires to register all computerized records of personal data and establishes rights to protect privacy against computer misdemeanor. All medical practitioners using computerized medical records must be aware that the infringement of this law may provoke suing in professional, civil or criminal court.

  8. Microcomputer Network for Computerized Adaptive Testing (CAT)

    Science.gov (United States)

    1984-03-01

    PRDC TR 84-33 \\Q.�d-33- \\ MICROCOMPUTER NETWOJlt FOR COMPUTERIZED ADAPTIVE TESTING ( CAT ) Baldwin Quan Thomas A . Park Gary Sandahl John H...ACCEIIION NO NPRDC TR 84-33 4. TITLE (-d Sul>tlllo) MICROCOMP UTER NETWORK FOR COMPUTERIZED ADA PTIVE TESTING ( CAT ) 1. Q B. uan T. A . Park...adaptive testing ( CAT ) Bayesian sequential testing 20. ABSTitACT (Continuo on ro•••• aide II noco .. _, _., ld-tlly ,.,. t.loclt _._.) DO Computerized

  9. Handheld computers in nursing education: PDA pilot project.

    Science.gov (United States)

    Koeniger-Donohue, Rebecca

    2008-02-01

    Interest in the use and application of handheld technology at undergraduate and graduate nursing programs across the country is growing rapidly. Personal digital assistants (PDAs) are often referred to as a "peripheral brain" because they can save time, decrease errors, and simplify information retrieval at the point of care. In addition, research results support the notion that PDAs enhance nursing clinical education and are an effective student learning resource. However, most nursing programs lack the full range of technological resources to implement and provide ongoing support for handheld technology use by faculty and students. This article describes a 9-month pilot project for the initial use of PDAs by novice faculty and students at Simmons College.

  10. Handheld Multi-Gas Meters Market Survey Report

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Gustavious [Brigham Young Univ., Provo, UT (United States); Wald-Hopkins, Mark David [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Obrey, Stephen J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Akhadov, Valida Dushdurova [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-23

    Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the chemical monitored. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. To provide emergency responders with information on handheld multi-gas meters, the System Assessment and Validation for Emergency Responders (SAVER) Program conducted a market survey. This market survey report is based on information gathered between November 2015 and February 2016 from vendors, Internet research, industry publications, an emergency responder focus group, and a government issued Request for Information (RFI) that was posted on the Federal Business Opportunities website.

  11. Mobile: Letting Go of the Device and Building for Innovation

    Science.gov (United States)

    Davis, Jim; Rocchio, Rosemary A.

    2011-01-01

    Mobile use of the Internet is on target to surpass fixed use by 2014. Three-fourths of all college/university students have purchased or intend to purchase an Internet-enabled handheld device within the next year. The smartphone market is changing almost monthly. Attempting to manage even just one or a few "devices" is becoming a lost…

  12. A computerized legal information management system | Ohiagu ...

    African Journals Online (AJOL)

    A computerized legal information management system. ... process through the filling system using the survey research methodology. ... A framework for the design and implementation of a legal information management system was presented.

  13. Computerizing marine biota: a rational approach

    Digital Repository Service at National Institute of Oceanography (India)

    Chavan, V.S.; Chandramohan, D.; Parulekar, A.H.

    Data on marine biota while being extensive are also patchy and scattered; thus making retrieval and dissemination of information time consuming. This emphasise the need for computerizing information on marine biota with the objective to collate...

  14. Human Reliability Analysis For Computerized Procedures

    International Nuclear Information System (INIS)

    Boring, Ronald L.; Gertman, David I.; Le Blanc, Katya

    2011-01-01

    This paper provides a characterization of human reliability analysis (HRA) issues for computerized procedures in nuclear power plant control rooms. It is beyond the scope of this paper to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper provides a review of HRA as applied to traditional paper-based procedures, followed by a discussion of what specific factors should additionally be considered in HRAs for computerized procedures. Performance shaping factors and failure modes unique to computerized procedures are highlighted. Since there is no definitive guide to HRA for paper-based procedures, this paper also serves to clarify the existing guidance on paper-based procedures before delving into the unique aspects of computerized procedures.

  15. Computerized Interpretation of Dynamic Breast MRI

    National Research Council Canada - National Science Library

    Chen, Weijie; Giger, Maryellen Lissak

    2005-01-01

    ... and prognosis of breast cancer. The research involves investigation of automatic methods for image artifacts correction, tumor segmentation, and extraction of computerized features that help distinguish between benign and malignant lesions...

  16. Carbonaceous species emitted from handheld two-stroke engines

    Science.gov (United States)

    Volckens, John; Olson, David A.; Hays, Michael D.

    Small, handheld two-stroke engines used for lawn and garden work (e.g., string trimmers, leaf blowers, etc.) can emit a variety of potentially toxic carbonaceous air pollutants. Yet, the emissions effluents from these machines go largely uncharacterized, constraining the proper development of human exposure estimates, emissions inventories, and climate and air quality models. This study samples and evaluates chemical pollutant emissions from the dynamometer testing of six small, handheld spark-ignition engines—model years 1998-2002. Four oil-gas blends were tested in each engine in duplicate. Emissions of carbon dioxide, carbon monoxide, and gas-phase hydrocarbons were predominant, and the PM emitted was organic matter primarily. An ANOVA model determined that engine type and control tier contributed significantly to emissions variations across all identified compound classes; whereas fuel blend was an insignificant variable accounting for engines were generally intermediate in magnitude compared with other gasoline-powered engines, numerous compounds traditionally viewed as motor vehicle markers are also present in small engine emissions in similar relative proportions. Given that small, handheld two-stroke engines used for lawn and garden work account for 5-10% of total US emissions of CO, CO 2, NO x, HC, and PM 2.5, source apportionment models and human exposure studies need to consider the effect of these small engines on ambient concentrations in air polluted environments.

  17. A smartphone controlled handheld microfluidic liquid handling system.

    Science.gov (United States)

    Li, Baichen; Li, Lin; Guan, Allan; Dong, Quan; Ruan, Kangcheng; Hu, Ronggui; Li, Zhenyu

    2014-10-21

    Microfluidics and lab-on-a-chip technologies have made it possible to manipulate small volume liquids with unprecedented resolution, automation and integration. However, most current microfluidic systems still rely on bulky off-chip infrastructures such as compressed pressure sources, syringe pumps and computers to achieve complex liquid manipulation functions. Here, we present a handheld automated microfluidic liquid handling system controlled by a smartphone, which is enabled by combining elastomeric on-chip valves and a compact pneumatic system. As a demonstration, we show that the system can automatically perform all the liquid handling steps of a bead-based HIV1 p24 sandwich immunoassay on a multi-layer PDMS chip without any human intervention. The footprint of the system is 6 × 10.5 × 16.5 cm, and the total weight is 829 g including battery. Powered by a 12.8 V 1500 mAh Li battery, the system consumed 2.2 W on average during the immunoassay and lasted for 8.7 h. This handheld microfluidic liquid handling platform is generally applicable to many biochemical and cell-based assays requiring complex liquid manipulation and sample preparation steps such as FISH, PCR, flow cytometry and nucleic acid sequencing. In particular, the integration of this technology with read-out biosensors may help enable the realization of the long-sought Tricorder-like handheld in vitro diagnostic (IVD) systems.

  18. Computerized provider order entry systems.

    Science.gov (United States)

    2001-01-01

    Computerized provider order entry (CPOE) systems are designed to replace a hospital's paper-based ordering system. They allow users to electronically write the full range of orders, maintain an online medication administration record, and review changes made to an order by successive personnel. They also offer safety alerts that are triggered when an unsafe order (such as for a duplicate drug therapy) is entered, as well as clinical decision support to guide caregivers to less expensive alternatives or to choices that better fit established hospital protocols. CPOE systems can, when correctly configured, markedly increase efficiency and improve patient safety and patient care. However, facilities need to recognize that currently available CPOE systems require a tremendous amount of time and effort to be spent in customization before their safety and clinical support features can be effectively implemented. What's more, even after they've been customized, the systems may still allow certain unsafe orders to be entered. Thus, CPOE systems are not currently a quick or easy remedy for medical errors. ECRI's Evaluation of CPOE systems--conducted in collaboration with the Institute for Safe Medication Practices (ISMP)--discusses these and other related issues. It also examines and compares CPOE systems from three suppliers: Eclipsys Corp., IDX Systems Corp., and Siemens Medical Solutions Health Services Corp. Our testing focuses primarily on the systems' interfacing capabilities, patient safeguards, and ease of use.

  19. Computerized automated remote inspection system

    International Nuclear Information System (INIS)

    The automated inspection system utilizes a computer to control the location of the ultrasonic transducer, the actual inspection process, the display of the data, and the storage of the data on IBM magnetic tape. This automated inspection equipment provides two major advantages. First, it provides a cost savings, because of the reduced inspection time, made possible by the automation of the data acquisition, processing, and storage equipment. This reduced inspection time is also made possible by a computerized data evaluation aid which speeds data interpretation. In addition, the computer control of the transducer location drive allows the exact duplication of a previously located position or flaw. The second major advantage is that the use of automated inspection equipment also allows a higher-quality inspection, because of the automated data acquisition, processing, and storage. This storage of data, in accurate digital form on IBM magnetic tape, for example, facilitates retrieval for comparison with previous inspection data. The equipment provides a multiplicity of scan data which will provide statistical information on any questionable volume or flaw. An automatic alarm for location of all reportable flaws reduces the probability of operator error. This system has the ability to present data on a cathode ray tube as numerical information, a three-dimensional picture, or ''hard-copy'' sheet. One important advantage of this system is the ability to store large amounts of data in compact magnetic tape reels

  20. Cone beam computerized tomography of face. Technological assessment report

    International Nuclear Information System (INIS)

    Saint-Pierre, Francoise; Fanelli, Gaelle; Mosnegutu, Lavinia; Devaux, Frederique

    2009-12-01

    Cone beam computerized tomography is an imagery technique notably used for the maxillofacial complex or a complete or limited exploration of maxillo-mandibular and dento-alveolar structures. Typically, this technique is implemented with devices which are different from scanners in various respects (performance of several linear cuts, use of an open cone beam). Based on a literature survey, this document reports an assessment which aimed at determining technical and dosimetric performances of the device, potential benefits in terms of diagnosis and therapy with respect to existing imagery techniques, specifications and role of this technique in odonto-stomatology, maxillofacial surgery, and even in ENT, and operation conditions and training to perform this act

  1. Handheld highly selective plasmonic chem/biosensor using engineered binding proteins for extreme conformational changes

    Science.gov (United States)

    Kosciolek, Derek J.; Sonar, Ajay; Lepak, Lori A.; Schnatz, Peter; Bendoym, Igor; Brown, Mia C.; Koder, Ronald L.; Crouse, David T.

    2017-08-01

    In this project we develop a handheld, portable, highly selective and sensitive chem/biosensor that has potential applications in both airborne and water-based environmental sensing. The device relies on a plasmonic chip of subwavelength-scale periodic gold rods engineered to resonate in the near infrared. The chip is functionalized with a novel class of proteins that exhibit large conformational changes upon binding to a specific target analyte. The subsequent change in local refractive index near the surface of the gold is one to two orders of magnitude greater than current conventional methods, which produces a readily measurable 5 to 10 percent difference in light transmission. This allows us to forgo traditional, bulky tabletop setups in favor of a compact form factor. Using commercially available optics to construct a transmission-based optical train, measured changes in bulk refractive index are presented here. While synthesis of binding protein efforts are focused on heme as analyte for proof of concept validation, the functionalized protein can be engineered to pair with a wide variety of analytes with minimal alterations to the plasmonic chip or device design. Such flexibility allows for this device to potentially meet the needs of first responders and health care professionals in a multitude of scenarios.

  2. Maintaining radiation exposures as low as reasonably achievable (ALARA) for dental personnel operating portable hand-held x-ray equipment.

    Science.gov (United States)

    McGiff, Thomas J; Danforth, Robert A; Herschaft, Edward E

    2012-08-01

    Clinical experience indicates that newly available portable hand-held x-ray units provide advantages compared to traditional fixed properly installed and operated x-ray units in dental radiography. However, concern that hand-held x-ray units produce higher operator doses than fixed x-ray units has caused regulatory agencies to mandate requirements for use of hand-held units that go beyond those recommended by the manufacturer and can discourage the use of this technology. To assess the need for additional requirements, a hand-held x-ray unit and a pair of manikins were used to measure the dose to a simulated operator under two conditions: exposures made according to the manufacturer's recommendations and exposures made according to manufacturer's recommendation except for the removal of the x-ray unit's protective backscatter shield. Dose to the simulated operator was determined using an array of personal dosimeters and a pair of pressurized ion chambers. The results indicate that the dose to an operator of this equipment will be less than 0.6 mSv y⁻¹ if the device is used according to the manufacturer's recommendations. This suggests that doses to properly trained operators of well-designed, hand-held dental x-ray units will be below 1.0 mSv y⁻¹ (2% of the annual occupational dose limit) even if additional no additional operational requirements are established by regulatory agencies. This level of annual dose is similar to those reported as typical dental personnel using fixed x-ray units and appears to satisfy the ALARA principal for this class of occupational exposures.

  3. Introducing handheld computing into a residency program: preliminary results from qualitative and quantitative inquiry.

    OpenAIRE

    Manning, B.; Gadd, C. S.

    2001-01-01

    Although published reports describe specific handheld computer applications in medical training, we know very little yet about how, and how well, handheld computing fits into the spectrum of information resources available for patient care and physician training. This paper reports preliminary quantitative and qualitative results from an evaluation study designed to track changes in computer usage patterns and computer-related attitudes before and after introduction of handheld computing. Pre...

  4. Computerized Adaptive Personality Testing: A Review and Illustration With the MMPI-2 Computerized Adaptive Version.

    Science.gov (United States)

    Forbey, Johnathan D.; Ben-Porath, Yossef S.

    2007-01-01

    Computerized adaptive testing in personality assessment can improve efficiency by significantly reducing the number of items administered to answer an assessment question. Two approaches have been explored for adaptive testing in computerized personality assessment: item response theory and the countdown method. In this article, the authors…

  5. The industrial computerized tomography applied to the rock analysis

    International Nuclear Information System (INIS)

    Tetzner, Guaraciaba de Campos

    2008-01-01

    This work is a study of the possibilities of the technical applications of Computerized Tomography (CT) by using a device developed in the Radiation Technology Center (CTR), Institute for Energy and Nuclear Research (IPEN-CNEN/SP). The equipment consists of a gamma radiation source ( 60 Co), a scintillation detector of sodium iodide doped with thallium (NaI (Tl)), a mechanical system to move the object (rotation and translation) and a computer system. This operating system has been designed and developed by the CTR-IPEN-CNEN/SP team using national resources and technology. The first validation test of the equipment was carried out using a cylindrical sample of polypropylene (phantom) with two cylindrical cavities (holes) of 5 x 25 cm (diameter and length). In these tests, the holes were filled with materials of different density (air, oil and metal), whose attenuation coefficients are well known. The goal of this first test was to assess the response quality of the equipment. The present report is a study comparing computerized tomography equipment CTR-IPEN-CNEN/SP which uses a source of gamma radiation ( 60 Co) and other equipment provided by the Department of Geosciences in the University of Texas (CTUT), which uses an X-ray source (450 kV and 3.2 mA). As a result, the images obtained and the comprehensive study of the usefulness of the equipment developed here strengthened the proposition that the development of industrial computerized tomography is an important step toward consolidating the national technology. (author)

  6. Bring-Your-Own-Device: Turning Cell Phones into Forces for Good

    Science.gov (United States)

    Imazeki, Jennifer

    2014-01-01

    Over the last few years, classroom response systems (or "clickers") have become increasingly common. Although most systems require students to use a standalone handheld device, bring-your-own-device (BYOD) systems allow students to use devices they already own (e.g., a cell phone, tablet or laptop) to submit responses via text message or…

  7. Evaluation of brain scintigraphy and computerized tomography

    International Nuclear Information System (INIS)

    Cavailloles, F.; Dairou, R.; Desbleds, M.T.; Benoit, C.; Larmande, P.; Bok, B.; Alperovitch, A.

    1983-01-01

    In order to assess the clinical usefulness of brain computerized tomography and radionuclide scan, a prospective study was performed on a series of 554 patients. The detection rate was assessed as well as the identification rate of lesions. In addition, the usefulness of both tests was appreciated subjectively by two neurologists reviewing the patients' files. Both give reasonably similar results: computerized tomography is superior to radionuclide scan in the diagnosis of tumors and intracerebral hematomas, the radionuclide scan being slightly superior in the diagnosis of purely ischemic CVA and subdural hematomas. The superiority which was subjectively conceded to computerized tomography was greater than that objectively demonstrated. However, clinical usefulness of computerized tomography was judged important in only 50% of the cases. Moreover, to request both computerized tomography and radionuclide scan appeared as having no interest in 83% of the cases. In that series, the diagnostic hypotheses were in agreement with the final diagnosis in 88% of the cases. Bias encountered in this type of studies are discussed [fr

  8. Computerized occlusal analysis in bruxism

    Directory of Open Access Journals (Sweden)

    Lazić Vojkan

    2006-01-01

    Full Text Available Introduction. Sleep bruxism as nocturnal parafunction, also known as tooth grinding, is the most common parasomnia (sleep disorder. Most tooth grinding occurs during rapid eye movement - REM sleep. Sleep bruxism is an oral habit characterized by rhythmic activity of the masticatory muscles (m. masseter that causes forced contact between dental surfaces during sleep. Sleep bruxism has been associated with craniomandibular disorders including temporomandibular joint discomfort, pulpalgia, premature loss of teeth due to excessive attrition and mobility, headache, muscle ache, sleep interruption of an individual and problems with removable and fixed denture. Basically, two groups of etiological factors can be distinguished, viz., peripheral (occlusal factors and central (pathophysiological and psychological factors. The role of occlusion (occlusal discrepancies as the causative factor is not enough mentioned in relation to bruxism. Objective. The main objective of this paper was to evaluate the connection between occlusal factors and nocturnal parafunctional activities (occlusal disharmonies and bruxism. Method. Two groups were formed- experimental of 15 persons with signs and symptoms of nocturnal parafunctional activity of mandible (mean age 26.6 years and control of 42 persons with no signs and symptoms of bruxism (mean age 26.3 yrs.. The computerized occlusal analyses were performed using the T-Scan II system (Tekscan, Boston, USA. 2D occlusograms were analyzed showing the occlusal force, the center of the occlusal force with the trajectory and the number of antagonistic tooth contacts. Results. Statistically significant difference of force distribution was found between the left and the right side of the arch (L%-R% (t=2.773; p<0.02 in the group with bruxism. The difference of the centre of occlusal force - COF trajectory between the experimental and control group was not significant, but the trajectory of COF was longer in the group of

  9. Formal Verification of Computerized Procedure with Colored Petri Nets

    International Nuclear Information System (INIS)

    Kim, Yun Goo; Shin, Yeong Cheol

    2008-01-01

    Computerized Procedure System (CPS) supports nuclear power plant operators in performing operating procedures which are instructions to guide in monitoring, decision making and controlling nuclear power plants. Computerized Procedure (CP) should be loaded to CPS. Due to its execution characteristic, computerized procedure acts like a software in CPS. For example, procedure flows are determined by operator evaluation and computerized procedure logic which are pre-defined. So the verification of Computerized Procedure logic and execution flow is needed before computerized procedures are installed in the system. Formal verification methods are proposed and the modeling of operating procedures with Coloured Petri Nets(CP-nets) is presented

  10. Adaptive RF front-ends for hand-held applications

    CERN Document Server

    van Bezooijen, Andre; van Roermund, Arthur

    2010-01-01

    The RF front-end - antenna combination is a vital part of a mobile phone because its performance is very relevant to the link quality between hand-set and cellular network base-stations. The RF front-end performance suffers from changes in operating environment, like hand-effects, that are often unpredictable. ""Adaptive RF Front-Ends for Hand-Held Applications"" presents an analysis on the impact of fluctuating environmental parameters. In order to overcome undesired behavior two different adaptive control methods are treated that make RF frond-ends more resilient: adaptive impedance control,

  11. Development of dual sensor hand-held detector

    Science.gov (United States)

    Sezgin, Mehmet

    2010-04-01

    In this paper hand-held dual sensor detector development requirements are considered dedicated to buried object detection. Design characteristics of such a system are categorized and listed. Hardware and software structures, ergonomics, user interface, environmental and EMC/EMI tests to be applied and performance test issues are studied. Main properties of the developed system (SEZER) are presented, which contains Metal Detector (MD) and Ground Penetrating Radar (GPR). The realized system has ergonomic structure and can detect both metallic and non-metallic buried objects. Moreover classification of target is possible if it was defined to the signal processing software in learning phase.

  12. Computerized tomography in orthopaedics and traumatology

    International Nuclear Information System (INIS)

    Boettger, E.; Heckl, R.; Rehabilitations-Krankenhaus Langensteinbach, Karlsbad

    1981-01-01

    Computerized tomography in traumatology is the selected method for the indications mentioned, so that angiographic investigations are only necessary in exceptional cases. Computerized tomography is also better than other methods when diagnozing soft part tumours, however, angiography is still indicated preoperatively for individual cases. CT is only good as additional help to conventional diagnostics with bone tumours. The differential diagnosis cysts-tumour is possible using contrast medium injections. The frequently large soft part share of tumours is recognizable with osteolytic tumours so that a better irradiation and operation planning can be effected. Diseases in the spinal canal can only be assessed with reservation using modern equipment. Lumbar dislocations of the disk can mostly not be sufficiently determined. Perivertebral abscesses can be certainly detected using computerized tomography. This is particularly so for abscesses prior to calcification. (orig.) [de

  13. Design, construction and performance of a portable handheld electrohydrodynamic multi-needle spray gun for biomedical applications.

    Science.gov (United States)

    Sofokleous, Panagiotis; Stride, Eleanor; Bonfield, William; Edirisinghe, Mohan

    2013-01-01

    Electrohydrodynamic (EHD) processing has attracted substantial interest in the technological and pharmaceutical sectors in recent years. Given the complexity of the process, exploring new ideas for EHD electrospraying and electrospinning delivery is a challenge. In this article, the design, construction and testing of a portable handheld EHD multi-needle device are described to produce multifunctional particles and fibers. Solid and encapsulated polymer particles and fibers were generated in order to study the performance of the device. The intrinsic properties of the feed solution/suspension and the processing conditions were adjusted to ensure robustness of the process and give uniform and reproducible products, with diameters ranging from the sub-micrometer scale to a few micrometers. These products have a broad range of applications in many advanced industrial sectors e.g. drug delivery systems, wound dressing patches, low calorie food products and cosmetics. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Ergonomic material-handling device

    Science.gov (United States)

    Barsnick, Lance E.; Zalk, David M.; Perry, Catherine M.; Biggs, Terry; Tageson, Robert E.

    2004-08-24

    A hand-held ergonomic material-handling device capable of moving heavy objects, such as large waste containers and other large objects requiring mechanical assistance. The ergonomic material-handling device can be used with neutral postures of the back, shoulders, wrists and knees, thereby reducing potential injury to the user. The device involves two key features: 1) gives the user the ability to adjust the height of the handles of the device to ergonomically fit the needs of the user's back, wrists and shoulders; and 2) has a rounded handlebar shape, as well as the size and configuration of the handles which keep the user's wrists in a neutral posture during manipulation of the device.

  15. Hand-Held Photometer for Instant On-Spot Quantification of Nucleic Acids, Proteins, and Cells.

    Science.gov (United States)

    Li, Shi-Hao; Jain, Abhinav; Tscharntke, Timo; Arnold, Tobias; Trau, Dieter W

    2018-02-20

    This paper presents a novel hand-held photometer, termed "Photopette", for on-spot absorbance measurements of biochemical analytes. The Photopette is a multicomponent, highly portable device with an overall weight of 160 g, which fits within 202 mm × 47 mm × 42 mm. Designed in the form factor of a micropipette, Photopette integrates a photodiode detector with light emitting diodes (LEDs) to form a highly customizable photometer which supports a wide variety of applications within the wavelengths between 260 and 1050 nm. A dual-purpose disposable reflective tip was designed to act as a sample holder and a light-reflecting system, which is in stark contrast to the operation of mainstream spectrophotometers and photometers. Small volume analytes may be measured with low sample loss using this proprietary CuveTip. A user-friendly software application running on smart devices was developed to control and read the values from Photopette via a low-energy Bluetooth link. This one-step strategy allows measurements on-spot without sample transfer, minimizing cross-contamination and human error. The results reported in this paper demonstrate Photopette's great potential to quantify DNA, direct protein, and cell density directly within the laminar flow hood. Results are compared with a Nanodrop 2000c spectrophotometer, a mainstream spectrophotometer for small-volume measurements.

  16. Estimating the accuracy of optic nerve sheath diameter measurement using a pocket-sized, handheld ultrasound on a simulation model.

    Science.gov (United States)

    Johnson, Garrett G R J; Zeiler, Frederick A; Unger, Bertram; Hansen, Gregory; Karakitsos, Dimitrios; Gillman, Lawrence M

    2016-12-01

    Ultrasound measurement of optic nerve sheath diameter (ONSD) appears to be a promising, rapid, non-invasive bedside tool for identification of elevated intra-cranial pressure. With improvements in ultrasound technology, machines are becoming smaller; however, it is unclear if these ultra-portable handheld units have the resolution to make these measurements precisely. In this study, we estimate the accuracy of ONSD measurement in a pocket-sized ultrasound unit. Utilizing a locally developed, previously validated model of the eye, ONSD was measured by two expert observers, three times with two machines and on five models with different optic nerve sheath sizes. A pocket ultrasound (Vscan, GE Healthcare) and a standard portable ultrasound (M-Turbo, SonoSite) were used to measure the models. Data was analyzed by Bland-Altman plot and intra-class correlation coefficient (ICC). The ICC between raters for the SonoSite was 0.878, and for the Vscan was 0.826. The between-machine agreement ICC was 0.752. Bland-Altman agreement analysis between the two ultrasound methods showed an even spread across the range of sheath sizes, and that the Vscan tended to read on average 0.33 mm higher than the SonoSite for each measurement, with a standard deviation of 0.65 mm. Accurate ONSD measurement may be possible utilizing pocket-sized, handheld ultrasound devices despite their small screen size, lower resolution, and lower probe frequencies. Further study in human subjects is warranted for all newer handheld ultrasound models as they become available on the market.

  17. Computerized management of plant intervention tasks

    International Nuclear Information System (INIS)

    Remacle, J.; Quoidbach, G.

    1993-01-01

    The concept of 'computerized management' of plant intervention tasks was developed by TRACTEBEL in 1983 for the Belgian power plants of ELECTRABEL. The main objective of the 'Computerized Management of Plant Intervention Tasks' is to help the staff of a nuclear or a conventional power plant in planning, organizing, and carrying out any (preventive or corrective) maintenance task. It consists of a group of interconnected functional modules acting on a unique and homogeneous data base. A short description of 3 modules is given, i.e., the 'User' Module, the 'Equipment' Module and the 'Periodic Procedure' Module. (Z.S.)

  18. Computerization of the safeguards analysis decision process

    International Nuclear Information System (INIS)

    Ehinger, M.H.

    1990-01-01

    This paper reports that safeguards regulations are evolving to meet new demands for timeliness and sensitivity in detecting the loss or unauthorized use of sensitive nuclear materials. The opportunities to meet new rules, particularly in bulk processing plants, involve developing techniques which use modern, computerized process control and information systems. Using these computerized systems in the safeguards analysis involves all the challenges of the man-machine interface experienced in the typical process control application and adds new dimensions to accuracy requirements, data analysis, and alarm resolution in the regulatory environment

  19. Computerized tomography in the diagnosis of hyperparathyroidism

    International Nuclear Information System (INIS)

    Sobota, J.; Girl, J.; Sotornik, I.; Kocandrle, V.

    1990-01-01

    Long-term experience in the application of computerized tomography to the diagnosis of hyperparathyroidism is summarized. Based on a large number of examinations (164) of parathyroid glands associated with the possibility of verification and comparison with the results of ultrasonography and other imaging methods, the potential of computerized tomography in the diagnosis of hyperparathyroidism and its advantages and limitations are summarized. It is concluded that owing to its high diagnostic precision, this technique can be regarded reliable in detecting enlarged parathyroid glands. (author). 11 figs., 1 tab., 19 refs

  20. Measuring thyroid uptake with hand-held radiation monitors

    International Nuclear Information System (INIS)

    Deschamps, M.

    1987-04-01

    With the use of Iodine 123, 125 and 131 and some compounds of Technetium-99 m, a fraction of the isotopes can be trapped in the thyroid of the technicians. We used the hand-held radiation contamination or survey meters of the nine (9) Nuclear medicine departments we visited to see if they were adequate for the evaluation of thyroid uptake of the users. Measurements on a neck-phanton helped us to determine a minimum detectable activity for each isotope. We were then able to check if the measurements of investigations and action levels were possible. None of the hand-held radiation monitors are completely satisfactory for the measure of thyroid uptake of the user. We discuss a class of equipment capable of measuring radiation emissions at the investigation level. Measurement at the action level is possible with meters having scintillation or proportional probes but none of them permits the discrimination in energy required for a quantitative evaluation of the radioisotopes used

  1. 75 FR 27504 - Substantial Product Hazard List: Hand-Held Hair Dryers

    Science.gov (United States)

    2010-05-17

    ... immersion during their use. Section 15(a) of the CPSA defines ``substantial product hazard'' to include, a....'' Hand-held hair dryers routinely contain open-coil heating elements that are, in essence, uninsulated..., bathtub, or lavatory). The proposed rule would define ``hand-held hair dryer'' as ``an electrical...

  2. 40 CFR 90.129 - Fuel tank permeation from handheld engines and equipment.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Fuel tank permeation from handheld... KILOWATTS Emission Standards and Certification Provisions § 90.129 Fuel tank permeation from handheld... equipment with respect to fuel tanks. For the purposes of this section, fuel tanks do not include fuel caps...

  3. The impact of legislation in Ireland on handheld mobile phone use by drivers.

    LENUS (Irish Health Repository)

    O'Meara, M

    2008-01-01

    Under the Road Traffic Act, 2006 handheld mobile phone use whilst driving is an offence liable to a fine and penalty points. The aim of this study was to determine whether there has been a change in driver behaviour following the introduction of this legislation. This study found that 2.3% of drivers were still using a handheld mobile phone.

  4. Study on a computerized compact simulator of NHR-200

    International Nuclear Information System (INIS)

    Gao Zuying; Dong Yujie

    1997-01-01

    A fully computerized compact simulator is studied in accordance with the engineering practical need of NHR-200. A SUN SPARC 2 stand-alone workstation is selected as its computer system and multi-task structure of software is employed. Simulation program is derived from the RETRAN-02 code. The standard I/O devices are used as its interface equipment and the man-machine interface graphic program is coded on the basis of X Window System. Shared memory and semaphores are used for inter-task communication and a timer is used in real-time control of tasks. Its accuracy and simulation speed are verified by using several typical accident transients. The accuracy and speed are perfectly able to meet the requirements of engineering simulation. It is useful for normal and accident transient analysis, engineering study and design, reactor operation support and personnel training

  5. Robinson's Computerized Strabismus Model Comes of Age

    NARCIS (Netherlands)

    H.J. Simonsz (Huib); H. Spekreijse (Henk)

    1996-01-01

    textabstractIn this article we review our further development of D.A. Robinson's computerized strabismus model. First, an extensive literature study has been carried out to get more accurate data on the anatomy of the average eye and the eye muscles, and about how these vary with age and with

  6. Computerized Italian criticality guide, description and validation

    International Nuclear Information System (INIS)

    Carotenuto, M.; Landeyro, P.A.

    1988-10-01

    Our group is developing an 'expert system' for collecting engineering know-how on back-end nuclear plant design. An expert system is the most suitable software tool for our problem. During the analysis, the design process was divided into different branches. At each branch of the design process the Expert System relates a computerized design procedure. Any design procedure is composed of a set of design methods, together with their condition of application and reliability limits. In the framework of this expert system, the nuclear criticality safety analysis procedure was developed, in the form of a computerized criticality guide, attempting to reproduce the designer's normal 'reasoning' process. The criticality guide is composed of two parts: A computerized text, including theory, a description of the accidents occurred in the past and a description of the italian design experience; An interactive computer aided calculation module, containing a graphical facility for critical parameter curves. In the present report are presented the criticality guide (computerized Italian Criticality Guide) and its validation test. (author)

  7. Computerized management information systems and organizational structures

    Science.gov (United States)

    Zannetos, Z. S.; Sertel, M. R.

    1970-01-01

    The computerized management of information systems and organizational structures is discussed. The subjects presented are: (1) critical factors favoring centralization and decentralization of organizations, (2) classification of organizations by relative structure, (3) attempts to measure change in organization structure, and (4) impact of information technology developments on organizational structure changes.

  8. Some procedures for computerized ability testing

    NARCIS (Netherlands)

    van der Linden, Willem J.; Zwarts, Michel A.

    1989-01-01

    For computerized test systems to be operational, the use of item response theory is a prerequisite. As opposed to classical test theory, in item response models the abilities of the examinees and the properties of the items are parameterized separately. Hence, when measuring the abilities of

  9. Implementation of a Computerized Maintenance Management System

    Science.gov (United States)

    Shen, Yong-Hong; Askari, Bruce

    1994-01-01

    A primer Computerized Maintenance Management System (CMMS) has been established for NASA Ames pressure component certification program. The CMMS takes full advantage of the latest computer technology and SQL relational database to perform periodic services for vital pressure components. The Ames certification program is briefly described and the aspects of the CMMS implementation are discussed as they are related to the certification objectives.

  10. Computerizing Maintenance Management Improves School Processes.

    Science.gov (United States)

    Conroy, Pat

    2002-01-01

    Describes how a Computerized Maintenance Management System (CMMS), a centralized maintenance operations database that facilitates work order procedures and staff directives, can help individual school campuses and school districts to manage maintenance. Presents the benefits of CMMS and things to consider in CMMS selection. (EV)

  11. The limited angle problem in computerized tomography

    International Nuclear Information System (INIS)

    Louis, A.K.

    1984-01-01

    Fast reconstruction formulae in X-ray computerized tomography demand the directions, in which the measurements are taken, to be equally distributed over the whole circle. In many applications data can only be provided in a restricted range. Here the intrinsic difficulties are studied by giving a singular value decomposition of the Radon transform in a restricted range. Practical limitations are deduced. (orig.)

  12. Ethics and the Computerization of Pharmacy.

    Science.gov (United States)

    McCarthy, Robert L.; Perrolle, Judith A.

    1991-01-01

    The current and potential impact of computerization on pharmacy practice is discussed, focusing on ethical dilemmas in the pharmacist-patient relationship, confidentiality of records, and the role of artificial intelligence in decision making about drug therapy. Case studies for use by teachers of pharmaceutical ethics are provided. (Author/MSE)

  13. Individual Differences in Computerized Adaptive Testing.

    Science.gov (United States)

    Kim, JinGyu

    Research on the major computerized adaptive testing (CAT) strategies is reviewed, and some findings are reported that examine effects of examinee demographic and psychological characteristics on CAT strategies. In fixed branching strategies, all examinees respond to a common routing test, the score of which is used to assign examinees to a…

  14. Computerized management support for swine breeding farms

    NARCIS (Netherlands)

    Huirne, R.B.M.

    1990-01-01

    1. INTRODUCTION

    The investigations described in this thesis have been directed towards computerized management support for swine breeding farms, focused on sow productivity and profitability. The study is composed of three basic parts: (1) basic description and

  15. Computerized three-dimensional normal atlas

    International Nuclear Information System (INIS)

    Mano, Isamu; Suto, Yasuzo; Suzuki, Masataka; Iio, Masahiro.

    1990-01-01

    This paper presents our ongoing project in which normal human anatomy and its quantitative data are systematically arranged in a computer. The final product, the Computerized Three-Dimensional Normal Atlas, will be able to supply tomographic images in any direction, 3-D images, and coded information on organs, e.g., anatomical names, CT numbers, and T 1 and T 2 values. (author)

  16. The Computerized Reference Department: Buying the Future.

    Science.gov (United States)

    Kriz, Harry M.; Kok, Victoria T.

    1985-01-01

    Basis for systematic computerization of academic research library's reference, collection development, and collection management functions emphasizes productivity enhancement for librarians and support staff. Use of microcomputer and university's mainframe computer to develop applications of database management systems, electronic spreadsheets,…

  17. Computerized system for measuring cerebral metabolism

    International Nuclear Information System (INIS)

    McGlone, J.S.; Hibbard, L.S.; Hawkins, R.A.; Kasturi, R.

    1987-01-01

    A computerized stereotactic measurement system for evaluating rat brain metabolism was developed to utilize the large amount of data generated by quantitative autoradiography. Conventional methods of measurement only analyze a small percent of these data because these methods are limited by instrument design and the subjectiveness of the investigator. However, a computerized system allows digital images to be analyzed by placing data at their appropriate three-dimensional stereotactic coordinates. The system automatically registers experimental data to a standard three-dimensional image using alignment, scaling, and matching operations. Metabolic activity in different neuronal structures is then measured by generating digital masks and superimposing them on to experimental data. Several experimental data sets were evaluated and it was noticed that the structures measured by the computerized system, had in general, lower metabolic activity than manual measurements had indicated. This was expected because the computerized system measured the structure over its volume while the manual readings were taken from the most active metabolic area of a particular structure

  18. How will computerization revolutionize managed care?

    Science.gov (United States)

    Trabin, T

    1994-01-01

    Computerization of behavioral health care information systems is revolutionizing how payors, managed care companies, and providers exchange information. In this article, an imaginary scenario is depicted of how patient data will be accessed and communicated to facilitate care management of behavioral health care services in the near future.

  19. Computerized Italian criticality guide, description and validation

    Energy Technology Data Exchange (ETDEWEB)

    Carotenuto, M; Landeyro, P A [ENEA - Dipartimento Ciclo del Combustibile, Centro Ricerche Energia, Casaccia (Italy)

    1988-10-15

    Our group is developing an 'expert system' for collecting engineering know-how on back-end nuclear plant design. An expert system is the most suitable software tool for our problem. During the analysis, the design process was divided into different branches. At each branch of the design process the Expert System relates a computerized design procedure. Any design procedure is composed of a set of design methods, together with their condition of application and reliability limits. In the framework of this expert system, the nuclear criticality safety analysis procedure was developed, in the form of a computerized criticality guide, attempting to reproduce the designer's normal 'reasoning' process. The criticality guide is composed of two parts: A computerized text, including theory, a description of the accidents occurred in the past and a description of the italian design experience; An interactive computer aided calculation module, containing a graphical facility for critical parameter curves. In the present report are presented the criticality guide (computerized Italian Criticality Guide) and its validation test. (author)

  20. Geometrical efficiency in computerized tomography: generalized model

    International Nuclear Information System (INIS)

    Costa, P.R.; Robilotta, C.C.

    1992-01-01

    A simplified model for producing sensitivity and exposure profiles in computerized tomographic system was recently developed allowing the forecast of profiles behaviour in the rotation center of the system. The generalization of this model for some point of the image plane was described, and the geometrical efficiency could be evaluated. (C.G.C.)

  1. Computerized reactor monitor and control for research reactors

    International Nuclear Information System (INIS)

    Buerger, L.; Vegh, E.

    1981-09-01

    The computerized process control system developed in the Central Research Institute for Physics, Budapest, Hungary, is described together with its special applications at research reactors. The nuclear power of the Hungarian research reactor is controlled by this computerized system, too, while in Lybia many interesting reactor-hpysical calculations are built into the computerized monitor system. (author)

  2. 39 CFR 501.15 - Computerized Meter Resetting System.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Computerized Meter Resetting System. 501.15... AND DISTRIBUTE POSTAGE EVIDENCING SYSTEMS § 501.15 Computerized Meter Resetting System. (a) Description. The Computerized Meter Resetting System (CMRS) permits customers to reset their postage meters at...

  3. Adjustment of the Kompleks Titan-2 monitoring computerized system at the Rovno NPP third unit

    International Nuclear Information System (INIS)

    Zigaev, B.P.

    1987-01-01

    Information signal origin and processing processes in the monitoring computerized system 'Komplex Titan-2' at the Rovno NPP third unit are considered. The system exercises control over the following production equipment parameters: the state of keys of control of lock fittings, mechanisms, regulators, reserve mechanism automatic shut-down circuit; the state of lock fittings, mechanisms, regulators, reserve mechanism automated switching on; parameter deviation from permissible values; interlock operation; protection system state; the state of autonomous units and devices

  4. Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study

    Science.gov (United States)

    Perraton, Luke G.; Bower, Kelly J.; Adair, Brooke; Pua, Yong-Hao; Williams, Gavin P.; McGaw, Rebekah

    2015-01-01

    Introduction Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to examine the reliability of different algorithms for RFD calculation and to examine the intra-rater, inter-rater, and inter-device reliability of HHD as well as the concurrent validity of HHD for the assessment of isometric lower limb muscle strength and power. Methods 30 healthy young adults (age: 23±5yrs, male: 15) were assessed on two sessions. Isometric muscle strength and power were measured using peak force and RFD respectively using two HHDs (Lafayette Model-01165 and Hoggan microFET2) and a criterion-reference KinCom dynamometer. Statistical analysis of reliability and validity comprised intraclass correlation coefficients (ICC), Pearson correlations, concordance correlations, standard error of measurement, and minimal detectable change. Results Comparison of RFD methods revealed that a peak 200ms moving window algorithm provided optimal reliability results. Intra-rater, inter-rater, and inter-device reliability analysis of peak force and RFD revealed mostly good to excellent reliability (coefficients ≥ 0.70) for all muscle groups. Concurrent validity analysis showed moderate to excellent relationships between HHD and fixed dynamometry for the hip and knee (ICCs ≥ 0.70) for both peak force and RFD, with mostly poor to good results shown for the ankle muscles (ICCs = 0.31–0.79). Conclusions Hand-held dynamometry has good to excellent reliability and validity for most measures of isometric lower limb strength and power in a healthy population, particularly for proximal muscle groups. To aid implementation we have created freely available software to extract these variables from data stored on the Lafayette device. Future research should examine the reliability

  5. Quantitative tissue parameters of Achilles tendon and plantar fascia in healthy subjects using a handheld myotonometer.

    Science.gov (United States)

    Orner, Sarah; Kratzer, Wolfgang; Schmidberger, Julian; Grüner, Beate

    2018-01-01

    The aim of the study was to examine the quantitative tissue properties of the Achilles tendon and plantar fascia using a handheld, non-invasive MyotonPRO device, in order to generate normal values and examine the biomechanical relationship of both structures. Prospective study of a large, healthy sample population. The study sample included 207 healthy subjects (87 males and 120 females) for the Achilles tendon and 176 healthy subjects (73 males and 103 females) for the plantar fascia. For the correlations of the tissue parameters of the Achilles tendon and plantar fascia an intersection of both groups was formed which included 150 healthy subjects (65 males and 85 females). All participants were measured in a prone position. Consecutive measurements of the Achilles tendon and plantar fascia were performed by MyotonPRO device at defined sites. For the left and right Achilles tendons and plantar fasciae all five MyotonPRO parameters (Frequency [Hz], Decrement, Stiffness [N/m], Creep and Relaxation Time [ms]) were calculated of healthy males and females. The correlation of the tissue parameters of the Achilles tendon and plantar fascia showed a significant positive correlation of all parameters on the left as well as on the right side. The MyotonPRO is a feasible device for easy measurement of passive tissue properties of the Achilles tendon and plantar fascia in a clinical setting. The generated normal values of the Achilles tendon and plantar fascia are important for detecting abnormalities in patients with Achilles tendinopathy or plantar fasciitis in the future. Biomechanically, both structures are positively correlated. This may provide new aspects in the diagnostics and therapy of plantar fasciitis and Achilles tendinopathy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Group differences in physician responses to handheld presentation of clinical evidence: a verbal protocol analysis

    Directory of Open Access Journals (Sweden)

    Pavlovic Nada J

    2007-07-01

    Full Text Available Abstract Background To identify individual differences in physicians' needs for the presentation of evidence resources and preferences for mobile devices. Methods Within-groups analysis of responses to semi-structured interviews. Interviews consisted of using prototypes in response to task-based scenarios. The prototypes were implemented on two different form factors: a tablet style PC and a pocketPC. Participants were from three user groups: general internists, family physicians and medicine residents, and from two different settings: urban and semi-urban. Verbal protocol analysis, which consists of coding utterances, was conducted on the transcripts of the testing sessions. Statistical relationships were investigated between staff physicians' and residents' background variables, self-reported experiences with the interfaces, and verbal code frequencies. Results 47 physicians were recruited from general internal medicine, family practice clinics and a residency training program. The mean age of participants was 42.6 years. Physician specialty had a greater effect on device and information-presentation preferences than gender, age, setting or previous technical experience. Family physicians preferred the screen size of the tablet computer and were less concerned about its portability. Residents liked the screen size of the tablet, but preferred the portability of the pocketPC. Internists liked the portability of the pocketPC, but saw less advantage to the large screen of the tablet computer (F[2,44] = 4.94, p = .012. Conclusion Different types of physicians have different needs and preferences for evidence-based resources and handheld devices. This study shows how user testing can be incorporated into the process of design to inform group-based customization.

  7. Accuracy of Handheld Point-of-Care Fingertip Lactate Measurement in the Emergency Department

    Directory of Open Access Journals (Sweden)

    Gaieski, David G

    2013-02-01

    Full Text Available Introduction: Early recognition of elevated lactate levels in sepsis may hasten the detection of those patients eligible for aggressive resuscitation. Point-of-care (POC testing is now increasingly available for use in the emergency department (ED. We examined the accuracy and time-saving effect of a handheld POC device for the measurement of fingertip and whole blood lactate as compared with reference laboratory testing in critically ill ED patients.Methods: A convenience sample of adult ED patients receiving serum lactate testing was prospectively enrolled at an urban, tertiary care US hospital. Consenting patients underwent fingertip POC lactate measurement with a portable device and simultaneous whole blood sampling for analysis by both the POC device and standard laboratory analyzer (‘‘reference method’’. Lactate measurements were compared by intraclass correlation (ICC and Bland and Altman plots. Differences in time to test result were compared by paired t test.Results: Twenty-four patients, 19 (79% with sepsis and 21 (88% with lactate levels below 4 mmol/L, were included from April 2005 to May 2005. Fingertip POC and whole blood POC lactate measurements each correlated tightly with the reference method (ICC ¼ 0.90 and ICC ¼ 0.92, respectively. Mean time between obtaining fingertip lactate samples and whole blood reference lactate samples was 8 6 13 minutes. Mean time between obtaining POC and reference laboratory lactate results was 65 minutes (95% confidence interval, 30–103.Conclusion: Fingertip POC lactate measurement is an accurate method to determine lactate levels in infected ED patients with normal or modestly elevated lactate values and significantly decreases time to test results. These findings should be verified in a larger, more critically ill, ED population. [West J Emerg Med. 2013;14(1:58-62.

  8. A sensitive, handheld vapor sensor based on microcantilevers

    Science.gov (United States)

    Pinnaduwage, L. A.; Hedden, D. L.; Gehl, A.; Boiadjiev, V. I.; Hawk, J. E.; Farahi, R. H.; Thundat, T.; Houser, E. J.; Stepnowski, S.; McGill, R. A.; Deel, L.; Lareau, R. T.

    2004-11-01

    We report the development of a handheld sensor based on piezoresistive microcantilevers that does not depend on optical detection, yet has high detection sensitivity. The sensor is able to detect vapors from the plastic explosives pentaerythritol tetranitrate and hexahydro-1,3,5-triazine at levels below 10 parts per trillion within few seconds of exposure under ambient conditions. A differential measurement technique has yielded a rugged sensor that is unaffected by vibration and is able to function as a "sniffer." The microelectromechanical system sensor design allows for the incorporation of hundreds of microcantilevers with suitable coatings in order to achieve sufficient selectivity in the future, and thus could provide an inexpensive, unique platform for the detection of chemical, biological, and explosive materials.

  9. Handheld Micromanipulator for Robot-Assisted Stapes Footplate Surgery

    Science.gov (United States)

    Grande, Gonzalo Montes; Knisely, Anna J.; Becker, Brian C.; Yang, Sungwook; Hirsch, Barry E.; Riviere, Cameron N.

    2012-01-01

    Stapes footplate surgery is complex and delicate. This surgery is carried out in the middle ear to improve hearing. High accuracy is required to avoid critical tissues and structures near the surgical worksite. By suppressing the surgeon’s tremor during the operation, accuracy can be improved. In this paper, a fully handheld active micromanipulator known as Micron is evaluated for its feasibility for this delicate operation. An ergonomic handle, a custom tip, and a brace attachment were designed for stapes footplate surgery and tested in a fenestration task through a fixed speculum. Accuracy was measured during simulated surgery in two different scenarios: Micron off (unaided) and Micron on (aided), both with image guidance. Preliminary results show that Micron significantly reduces the mean position error and the mean duration of time spent in specified dangerous zones. PMID:23366167

  10. Comparative Geometrical Investigations of Hand-Held Scanning Systems

    Science.gov (United States)

    Kersten, T. P.; Przybilla, H.-J.; Lindstaedt, M.; Tschirschwitz, F.; Misgaiski-Hass, M.

    2016-06-01

    An increasing number of hand-held scanning systems by different manufacturers are becoming available on the market. However, their geometrical performance is little-known to many users. Therefore the Laboratory for Photogrammetry & Laser Scanning of the HafenCity University Hamburg has carried out geometrical accuracy tests with the following systems in co-operation with the Bochum University of Applied Sciences (Laboratory for Photogrammetry) as well as the Humboldt University in Berlin (Institute for Computer Science): DOTProduct DPI-7, Artec Spider, Mantis Vision F5 SR, Kinect v1 + v2, Structure Sensor and Google's Project Tango. In the framework of these comparative investigations geometrically stable reference bodies were used. The appropriate reference data were acquired by measurement with two structured light projection systems (AICON smartSCAN and GOM ATOS I 2M). The comprehensive test results of the different test scenarios are presented and critically discussed in this contribution.

  11. COMPARATIVE GEOMETRICAL INVESTIGATIONS OF HAND-HELD SCANNING SYSTEMS

    Directory of Open Access Journals (Sweden)

    T. P. Kersten

    2016-06-01

    Full Text Available An increasing number of hand-held scanning systems by different manufacturers are becoming available on the market. However, their geometrical performance is little-known to many users. Therefore the Laboratory for Photogrammetry & Laser Scanning of the HafenCity University Hamburg has carried out geometrical accuracy tests with the following systems in co-operation with the Bochum University of Applied Sciences (Laboratory for Photogrammetry as well as the Humboldt University in Berlin (Institute for Computer Science: DOTProduct DPI-7, Artec Spider, Mantis Vision F5 SR, Kinect v1 + v2, Structure Sensor and Google’s Project Tango. In the framework of these comparative investigations geometrically stable reference bodies were used. The appropriate reference data were acquired by measurement with two structured light projection systems (AICON smartSCAN and GOM ATOS I 2M. The comprehensive test results of the different test scenarios are presented and critically discussed in this contribution.

  12. Simple Magnetic Device Indicates Thickness Of Alloy 903

    Science.gov (United States)

    Long, Pin Jeng; Rodriguez, Sergio; Bright, Mark L.

    1995-01-01

    Handheld device called "ferrite indicator" orginally designed for use in determining ferrite content of specimen of steel. Placed in contact with specimen and functions by indicating whether magnet attracted more strongly to specimen or to calibrated reference sample. Relative strength of attraction shows whether alloy overlay thinner than allowable.

  13. Utilization of ocular safety devices among Sawmill workers in Nigeria

    African Journals Online (AJOL)

    Objective: The study was carried out to assess the use of eye safety devices in sawmill workers in Nigeria. Methods: A cross-sectional study of sawmill workers was carried out using pretested questionnaires. Ocular examination was done on site with a pen torch, portable hand-held slit lamp bio-microscope and direct ...

  14. 3D indoor modeling using a hand-held embedded system with multiple laser range scanners

    Science.gov (United States)

    Hu, Shaoxing; Wang, Duhu; Xu, Shike

    2016-10-01

    Accurate three-dimensional perception is a key technology for many engineering applications, including mobile mapping, obstacle detection and virtual reality. In this article, we present a hand-held embedded system designed for constructing 3D representation of structured indoor environments. Different from traditional vehicle-borne mobile mapping methods, the system presented here is capable of efficiently acquiring 3D data while an operator carrying the device traverses through the site. It consists of a simultaneous localization and mapping(SLAM) module, a 3D attitude estimate module and a point cloud processing module. The SLAM is based on a scan matching approach using a modern LIDAR system, and the 3D attitude estimate is generated by a navigation filter using inertial sensors. The hardware comprises three 2D time-flight laser range finders and an inertial measurement unit(IMU). All the sensors are rigidly mounted on a body frame. The algorithms are developed on the frame of robot operating system(ROS). The 3D model is constructed using the point cloud library(PCL). Multiple datasets have shown robust performance of the presented system in indoor scenarios.

  15. Handheld tympanometer measurements in conscious dogs for the evaluation of the middle ear and auditory tube.

    Science.gov (United States)

    Strain, George M; Fernandes, Asia J

    2015-06-01

    Otitis externa is frequently accompanied by otitis media, yet it can be difficult to evaluate the tympanum, middle ear and auditory tube without the use of advanced radiographic imaging. The objective was to develop techniques for tympanometry testing in conscious dogs and to present normative data for clinical use of this equipment to enable assessment of the tympanum, middle ear and auditory tube. Sixteen hounds (14 female) from a school teaching colony. Dogs were gently restrained in a standing position. After cleaning of the ear canal, a tympanometer probe tip extension was placed in the vertical canal and automated testing performed using a handheld device. Both ears were tested in all dogs. Acceptable recordings were obtained from both ears of 13 dogs, from one ear in each of two dogs and from neither ear of one dog, resulting in data from 28 of 32 (88%) ears. Otoscopic examination confirmed the absence of inflammation or any other obvious explanation for the noncompliant dogs. No significant differences were seen between ears for any measure. Normative data are reported for peak compliance, peak compliance pressure, gradient and ear canal volume. Tympanograms can be recorded in conscious dogs to assist in the evaluation of the middle ear structures. © 2015 ESVD and ACVD.

  16. Three-dimensional modeling of physiological tremor for hand-held surgical robotic instruments.

    Science.gov (United States)

    Tatinati, Sivanagaraja; Yan Naing Aye; Pual, Anand; Wei Tech Ang; Veluvolu, Kalyana C

    2016-08-01

    Hand-held robotic instruments are developed to compensate physiological tremor in real-time while augmenting the required precision and dexterity into normal microsurgical work-flow. The hardware (sensors and actuators) and software (causal linear filters) employed for tremor identification and filtering introduces time-varying unknown phase-delay that adversely affects the device performance. The current techniques that focus on three-dimensions (3D) tip position control involves modeling and canceling the tremor in 3-axes (x, y, and z axes) separately. Our analysis with the tremor data recorded from surgeons and novice subjects show that there exists significant correlation in tremor motion across the dimensions. Motivated by this, a new multi-dimensional modeling approach based on extreme learning machines (ELM) is proposed in this paper to correct the phase delay and to accurately model tremulous motion in three dimensions simultaneously. A study is conducted with tremor data recorded from the microsurgeons to analyze the suitability of proposed approach.

  17. Handheld Raman Spectroscopy for the Distinction of Essential Oils Used in the Cosmetics Industry

    Directory of Open Access Journals (Sweden)

    Paul Vargas Jentzsch

    2015-05-01

    Full Text Available Essential oils are highly appreciated by the cosmetics industry because they have antimicrobial and antioxidant properties, among others. Since essential oils are natural products, their inclusion in cosmetic formulations is a common practice. Currently, low-quality and/or adulterated essential oils can be found on the market; therefore, analytical methods for control are required. Raman spectroscopy is a versatile technique that can be used for quality control tasks; the portability of modern devices expand the analytical possibilities also to in situ measurements. Fifteen essential oils of interest for the cosmetics industry were measured using a handheld Raman spectrometer, and the assignment of the main bands observed in their average spectra was proposed. In most cases, it is possible to distinguish the essential oils by a simple visual inspection of their characteristic Raman bands. However, for essential oils extracted from closely-related vegetable species and containing the same main component in a very high proportion, the visual inspection of the spectra may be not enough, and the application of chemometric methods is suggested. Characteristic Raman bands for each essential oil can be used to both identify the essential oils and detect adulterations.

  18. Computerized tomography in atypical Pott's disease

    International Nuclear Information System (INIS)

    Cabrera, M.N.B.; Wang, E.H.M.

    1993-01-01

    Classical Pott's disease is described as a two-vertebrae disease with the destruction of the intervening invertebral disc. Computerized tomography has been used in the differential diagnosis of spine infections and neoplasms. We reviewed CT scans of patients seen at the Philippine General Hospital over a two-year period with atypical presentations of atypical tuberculous spondylitis. We used the computerized tomography findings described as characteristic of classical Pott's disease as criteria in evaluating the CT scans of patients diagnosed to have Atypical Pott's Disease. Although the number of patients prevented sensitivity and specificity studies to be done, our results strongly suggest that the same CT criteria used to diagnose Classical Pott's Disease may also be used to diagnose Pott's disease in its atypical form. (Author.). 13 refs

  19. Computerized flow monitors detect small kicks

    Energy Technology Data Exchange (ETDEWEB)

    McCann, D.; White, D. (Sedco Forex, Paris (FR))

    1992-02-24

    This paper reports on a smart alarm system installed on a number of offshore rigs and one land rig which can detect kicks more quickly than conventional systems. This rapid kick detection improves rig safety because the smaller the detected influx, the easier it is to control the well. The extensive computerized monitoring system helps drilling personnel detect fluid influxes and fluid losses before the changes in flow would normally be apparent.

  20. The EORTC emotional functioning computerized adaptive test

    DEFF Research Database (Denmark)

    Gamper, Eva-Maria; Grønvold, Mogens; Petersen, Morten Aa

    2014-01-01

    The European Organisation for Research and Treatment of Cancer (EORTC) Quality of Life Group is currently developing computerized adaptive testing measures for the Quality of Life Questionnaire Core-30 (QLQ-C30) scales. The work presented here describes the development of an EORTC item bank for e...... for emotional functioning (EF), which is one of the core domains of the QLQ-C30....

  1. 10 years of computerized tomography reviewed

    International Nuclear Information System (INIS)

    Duemmling, K.

    1984-01-01

    The history and some highlights of computerized tomography are reviewed. The various technologies employed in the course of CT development are described along with the limitations that led to their disappearance. The problems still to be solved in medicine, the increasing influence of nuclear magnetic resonance, and some scientific aspects have opened up new lines of development which are briefly mentioned. (orig./WU) [de

  2. Computerized reactor pressure vessel materials information system

    International Nuclear Information System (INIS)

    Strosnider, J.; Monserrate, C.; Kenworthy, L.D.; Tether, C.D.

    1980-10-01

    A computerized information system for storage and retrieval of reactor pressure vessel materials data was established, as part of Task Action Plan A-11, Reactor Vessel Materials Toughness. Data stored in the system are necessary for evaluating the resistance of reactor pressure vessels to flaw-induced fracture. This report includes (1) a description of the information system; (2) guidance on accessing the system; and (3) a user's manual for the system

  3. Computerized reactor power regulation with logarithmic controller

    International Nuclear Information System (INIS)

    Gossanyi, A.; Vegh, E.

    1982-11-01

    A computerized reactor control system has been operating at a 5 MW WWR-SM research reactor in the Central Research Institute for Physics, Budapest, for some years. This paper describes the power controller used in the SPC operating mode of the system, which operates in a 5-decade wide power range with +-0.5% accuracy. The structure of the controller easily limits the minimal reactor period and produces a reactor transient with constant period if the power demand changes. (author)

  4. COMPRESS - a computerized reactor safety system

    International Nuclear Information System (INIS)

    Vegh, E.

    1986-01-01

    The computerized reactor safety system, called COMPRESS, provides the following services: scram initiation; safety interlockings; event recording. The paper describes the architecture of the system and deals with reliability problems. A self-testing unit checks permanently the correct operation of the independent decision units. Moreover the decision units are tested by short pulses whether they can initiate a scram. The self-testing is described in detail

  5. Computerized UT system for stud bolt

    International Nuclear Information System (INIS)

    Kisanuki, T.; Uchida, K.; Fushimi, T.; Onda, K.

    1988-01-01

    Cracking of stud bolts used in steam turbine casing, valve and pressure vessel has caused concern regarding the safety and reliability of power plants. In order to detect harmful cracks in early state, the improvement of UT technique is required. As regarding the ultrasonic inspection technique, a longitudinal beam technique and/or an angle beam technique are generally used. The authors report their development of a computerized UT system for bolt inspection and improvement of the angle beam technique

  6. Computerized tomography of gall bladder cancer

    International Nuclear Information System (INIS)

    Todua, F.I.; Karmazanovskij, G.G.

    1989-01-01

    The authors have summed up the experience in the use of computerized tomography (CT) in diagnosis of gall bladder cancer. The investigation of 17 patients with cancer of this site showed a high informative value of the method. A retrospective comparative study of the results of CT and surgical interventions was carried out. It has been concluded that CT makes it possible not only to diagnose malignant lesions of the bile ducts but also to assess a possible scope of a forthcoming operation

  7. Computerized dosimetry management systems within EDF

    International Nuclear Information System (INIS)

    Daubert, G.

    1996-01-01

    EDF, using the ALARA approach, has embarked an ambitious project of optimising the doses received in its power plants. In directing its choice of actions and the effectiveness of such actions, the French operator is using a computerized personal and collective dosimetry management system. This system provides for ongoing monitoring of dosimetry at personal, site and unit level or indeed for the entire population of EDF nuclear power plants. (author)

  8. Increased intracranial pressure: evaluation by computerized tomography

    International Nuclear Information System (INIS)

    Lightfoote, W.E.; Pressman, B.D.

    1975-01-01

    Computerized tomography is clearly very useful in the evaluation of patients with increased intracranial pressure and suspected pseudotumor cerebri. It provides an index of ventricular size and configuration and has the capability of demonstrating intracranial lesions. Moreover, this new technique is rapid and non-invasive, and is without attendant risks. Examinations may be performed serially as the clinical process evolves, thereby giving roentgenographic correlation to the clinical features. (U.S.)

  9. Computerized tomographic diagnosis of basal skull fracture

    International Nuclear Information System (INIS)

    Tanaka, Tokutaro; Shimoyama, Ichiro; Endoh, Mitsutoshi; Ninchoji, Toshiaki; Uemura, Kenichi.

    1984-01-01

    The diagnosis of basal skull fractures used to be difficult, particularly on the basis of routine skull roentgenography alone. We have now examined the diagnostic value of conventional computerized tomography in basal skull fractures. We studied 82 cases clinically diagnosed as basal skull fractures. We examined them based on at least one of the following computerized tomographic criteria for basal skull fractures: 1) fracture line(s), 2) intracranial air, 3) fluid in the paranasal sinuses, and 4) fluid in the middle ear, including the mastoid air cells. The signs of the fracture line and of the intracranial air are definite indications of basal skull fracture, but the signs of fluid in the paranasal sinuses and/or in the middle ear are not definite. When combined, however, with such other clinical signs as black eye, Battle's sign, CSF leakage, CSF findings, and profuse nasal or ear bleeding, the diagnosis is more reliable. Seventy cases (85.4%) in this series had basal skull fractures according to our computerized tomographic criteria. Among them , 26 cases (31.7%) were diagnosed with fracture lines, 17 cases (20.7%) with intracranial air, 16 cases (19.5%) with fluid in the paranasal sinuses, 10 cases (12.2%) with fluid in the middle ear, and one case (1.2%) with fluid in both. Twelve cases (14.6%) of the 82 cases clinically diagnosed as basal skull fractures could not have been diagnosed on our computerized tomographic criteria alone. We diagnosed them because of CSF leakage, CSF findings, surgical findings, etc. (author)

  10. Hand-held multi-DOF robotic forceps for neurosurgery designed for dexterous manipulation in deep and narrow space.

    Science.gov (United States)

    Okubo, Takuro; Harada, Kanako; Fujii, Masahiro; Tanaka, Shinichi; Ishimaru, Tetsuya; Iwanaka, Tadashi; Nakatomi, Hirohumi; Sora, Sigeo; Morita, Akio; Sugita, Naohiko; Mitsuishi, Mamoru

    2014-01-01

    Neurosurgical procedures require precise and dexterous manipulation of a surgical suture in narrow and deep spaces in the brain. This is necessary for surgical tasks such as the anastomosis of microscopic blood vessels and dura mater suturing. A hand-held multi-degree of freedom (DOF) robotic forceps was developed to aid the performance of such difficult tasks. The diameter of the developed robotic forceps is 3.5 mm, and its tip has three DOFs, namely, bending, rotation, and grip. Experimental results showed that the robotic forceps had an average needle insertion force of 1.7 N. Therefore, an increase in the needle insertion force is necessary for practical application of the developed device.

  11. Development of a low cost, GPS-based upgrade to a standard handheld gamma detector for mapping environmental radioactive contamination.

    Science.gov (United States)

    Paridaens, J

    2006-02-01

    A low cost extension to a standard handheld radiation monitor was developed, allowing one to perform outdoor georeferenced gamma measurements. It consists of a commercial wireless Bluetooth GPS receiver, a commercial RS-232 to Bluetooth converter combined with a standard Bluetooth enabled pocket personal computer (PPC). The system is intended for use in difficult to access areas, typically for foot campaigns. As the operator walks, a straightforward homemade visual basic program alternately reads GPS position and gamma dose rate into the PPC, creating a data log. This allows a single operator on foot to map between 50 and 200 ha of environmental radiation per day in very rugged areas, depending on the accessibility of the terrain and the detail required. On a test field with known contamination, a spatial precision of about 5-10 m was obtainable. The device was also used to reveal complex contamination patterns in the flooding zones of a radioactively contaminated small river.

  12. Computerized materials protection, control, and accountability

    International Nuclear Information System (INIS)

    Whiteson, R.; Seitz, S.; Landry, R.P.; Hadden, M.L.; Painter, J.A.

    1997-01-01

    The proliferation of nuclear weapons, along with the technical knowledge and materials needed to make these weapons, is an enduring problem of international urgency. Current international nuclear nonproliferation efforts are aimed at deterring, detecting, and responding to proliferation of weapons of mass destruction. These safeguards efforts are being implemented by applying preeminent science and technology to the management and control of nuclear materials. By strengthening systems of nuclear material protection, control, and accountability (MPC and A), one can reduce the threat of nuclear weapons proliferation. Two major programs of international cooperation are now underway to achieve this goal. The first is between the US Department of Energy (DOE) and the Institutes of the Russian Federation (Laboratory-to-Laboratory Program), and the second is between the US Government and Governments of the former Soviet Republics (Government-to-Government Program). As part of these programs, the DOE is working with facilities to assist them in implementing computerized MPC and A systems. This work is a collaboration between computer scientists and safeguards experts in both the US and the new Republics. The US is making available technology and expertise to enable Russian experts to build on computerized MPC and A software developed in the US. This paper describes the joint efforts of these international teams to develop sophisticated computerized MPC and A systems using modern computer hardware and software technology. These systems are being customized to meet the site-specific needs of each facility

  13. Computerized analysis of brain perfusion parameter images

    International Nuclear Information System (INIS)

    Turowski, B.; Haenggi, D.; Wittsack, H.J.; Beck, A.; Aurich, V.

    2007-01-01

    Purpose: The development of a computerized method which allows a direct quantitative comparison of perfusion parameters. The display should allow a clear direct comparison of brain perfusion parameters in different vascular territories and over the course of time. The analysis is intended to be the basis for further evaluation of cerebral vasospasm after subarachnoid hemorrhage (SAH). The method should permit early diagnosis of cerebral vasospasm. Materials and Methods: The Angiotux 2D-ECCET software was developed with a close cooperation between computer scientists and clinicians. Starting from parameter images of brain perfusion, the cortex was marked, segmented and assigned to definite vascular territories. The underlying values were averages for each segment and were displayed in a graph. If a follow-up was available, the mean values of the perfusion parameters were displayed in relation to time. The method was developed under consideration of CT perfusion values but is applicable for other methods of perfusion imaging. Results: Computerized analysis of brain perfusion parameter images allows an immediate comparison of these parameters and follow-up of mean values in a clear and concise manner. Values are related to definite vascular territories. The tabular output facilitates further statistic evaluations. The computerized analysis is precisely reproducible, i. e., repetitions result in exactly the same output. (orig.)

  14. Computerized management of plant intervention tasks

    International Nuclear Information System (INIS)

    Quoidbach, G.

    2004-01-01

    The main objective of the 'Computerized Management of Plant Intervention Tasks' is to help the staff of a nuclear or a conventional power plant or of any other complex industrial facility (chemical industries, refineries, and so on) in planning, organizing, and carrying out any (preventive or corrective) maintenance task. This 'Computerized Management of Plant Intervention Tasks' is organized around a data base of all plant components in the facility that might be subjected to maintenance or tagout. It allows to manage, by means of intelligent and configurable 'mail service', the course of the intervention requests as well as various treatments of those requests, in a safe and efficient way, adapted to each particular organization. The concept of 'Computerized Management' of plant intervention tasks was developed by BELGATOM in 1983 for the Belgian nuclear power plants of ELECTRABEL. A first implementation of this concept was made at that time for the Doel NPP under the name POPIT (Programming Of Plant Intervention Tasks). In 1988, it was decided to proceed to a functional upgrade of the application, using advanced software and hardware techniques and products, and to realize a second implementation in the Tihange NPP under the name ACM (Application Consignation Maintenance). (author)

  15. Diversity in computerized reactor protection systems

    International Nuclear Information System (INIS)

    Fischer, H.D.; Piel, L.

    1999-01-01

    Based on engineering judgement, the most important measures to increase the independency of redundant trains of a computerized safety instrumentation and control system (I and C) in a nuclear power plant are evaluated with respect to practical applications. This paper will contribute to an objective discussion on the necessary and justifiable arrangement of diversity in a computerized safety I and C system. Important conclusions are: - (i) diverse equipment may be used to control dependent failures only if measures necessary for designing, licensing, and operating a computerized safety I and C system homogeneous in equipment are neither technically nor economically feasible; - (ii) the considerable large operating experience in France with a non-diverse equipment digital reactor protection system does not call for equipment diversity. Although there are no generally accepted methods, the licensing authority is still required to take into account dependent failures in a probabilistic safety analysis; - (ii) the frequency of postulated initiating events implies which I and C functionality should be implemented on diverse equipment. Using non-safety I and C equipment in addition to safety I and C equipment is attractive because its necessary unavailability to control an initiating event in teamwork with the safety I and C equipment is estimated to range from 0.01 to 0.1. This can be achieved by operational experience

  16. Staging of bronchogenic carcinoma by computerized tomography

    International Nuclear Information System (INIS)

    Sommer, B.; Bauer, W.M.; Rath, M.; Fenzl, G.; Stelter, W.J.; Lissner, J.

    1981-01-01

    It was possible to check the information obtained by CT scanning in 36 patients out of 49 who had been subjected to computerized tomography, in respect of the extension of the primary tumour (T stage), and in 25 patients in respect of the degree of mediastinal lymphatic node involvement (N stage). In all 49 patients, the presence of bronchogenic carcinoma had been safely established. In 97% of the cases, assessment of the extension of the primary tumour was found to be correct. Assessment of the N stage, however, is more problematic, since detection of mediastinal lymphatic nodes by computerized tomography does not necessarily tell us something about their metastatic involvement. If all recognizable lymphatic nodes are interpreted as potential metastases, we have no false negative but 61% false positive results because of the frequency of postinflammatory or anthracotic lymphatic nodes. In case of exclusive assessment of lymphatic node enlargement above 1 cm diameter, the rate of metastatic nodes increases considerably (83%). Computerized tomography is definitely superior to all roentgenological methods in assessing the stage of a bronchogenic carcinoma; hence, it could occupy a key position in determining the diagnostic and therapeutic approach in patients with this disease. (orig.) [de

  17. Case of neurosarcoidosis monitored by computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kubota, T; Kimura, M; Komai, T; Yamamoto, S; Yamamura, I [Kanazawa Univ. (Japan). School of Medicine

    1979-12-01

    A 21-year-old man complaining of impaired visual acuity was admitted to the hospital. Physical examinations showed asymptomatic bilateral hilar lymphadenopathy and cardiomyopathy. Neurological findings disclosed left blindness and right temporal hemianopsia. Computerized tomography, pneumoencephalography and carotid angiography revealed a suprasellar mass. After the admission, the following symptoms deteriorated rapidly: diabetes insipidus, anterior pituitary dysfunction, visual loss of the right eye and hepatomegaly, subsequently consciousness disorder developed during a month though he was given steroids. The more deteriorated the clinical course, the larger the suprasellar mass with expanding hydrocephalus in repeated computerized tomographies. After the ventriculo-peritoneal shunt operation, consciousness improved. Diabetes insipidus also improved after Diabenese administration. On the operation, adhesive arachnoiditis over all the frontotemporal cortex and swollen purplishly red optic chiasm were exposed. Microscopically the specimen from the optic chiasm evidenced a sarcoid granuloma which composed of epitheroid cells, lymphocytes and multi-nucleated giant cells with numerous hemosiderin droplets. The specimen from the surface of the left frontal lobe showed thick fibrosis in the subarachnoid space. By steroids therapy, diabetes insipidus and hepatomegaly disappeared five months after the admission, whereas blindness never recovered. He died of developed status epilepticus eleven months after the admission. The authors reviewed neuroradiological findings of neurocarcoidosis based on pathological findings in the literature, and emphasized that computerized tomography was the most useful for diagnosis and treatment of neurosarcoidosis.

  18. The use of handheld GPS to determine tidal slack in estuaries

    Science.gov (United States)

    Lievens, M.; Savenije, H.; Luxemburg, W.

    2010-12-01

    The phase lag between the moment of high water and high water slack, respectively low water and low water slack, is a key parameter in tidal hydraulics which is often disregarded. Savenije (1992) found that there are simple analytical relations for estuary topography, wave celerity and phase lag, that can be derived from the equation for conservation of mass and momentum. At present, methods to determine the phase lag by measuring the moment of tidal slack in the field are often either inadequate or very expensive. To be sure if assumptions made for the analytical derivation are acceptable, measuring the ‘real’ moment of tidal slack in the field is necessary. The method to determine the exact moment of tidal slack, developed in this work, is based on the use of a simple handheld GPS at some locations in the Dutch part of the Scheldt estuary. The GPS device is attached to a shipping lane buoy, which is fixed to the bottom of the estuary with a long chain. The chain gives the buoy enough space for an amplitude of approximately 25 - 30 meters. The GPS device measures the location of the buoy every 30 seconds for a few days. The data from the GPS results in a nice view of the path that the buoy travelled. The moment that the buoy switches direction, should be the moment of tidal slack. The “GPS method” of measuring the phase lag would allow application on full estuary scale in the future. Besides that, we get more insight in the key parameter of slack times for tidal hydraulics. The results are also of key importance to commercial shipping, towage and salvage companies and other users of estuaries worldwide.

  19. Pocket data mining big data on small devices

    CERN Document Server

    Gaber, Mohamed Medhat; Gomes, Joao Bartolo

    2014-01-01

    Owing to continuous advances in the computational power of handheld devices like smartphones and tablet computers, it has become possible to perform Big Data operations including modern data mining processes onboard these small devices. A decade of research has proved the feasibility of what has been termed as Mobile Data Mining, with a focus on one mobile device running data mining processes. However, it is not before 2010 until the authors of this book initiated the Pocket Data Mining (PDM) project exploiting the seamless communication among handheld devices performing data analysis tasks that were infeasible until recently. PDM is the process of collaboratively extracting knowledge from distributed data streams in a mobile computing environment. This book provides the reader with an in-depth treatment on this emerging area of research. Details of techniques used and thorough experimental studies are given. More importantly and exclusive to this book, the authors provide detailed practical guide on the depl...

  20. Handheld Longwave Infrared Camera Based on Highly-Sensitive Quantum Well Infrared Photodetectors, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop a compact handheld longwave infrared camera based on quantum well infrared photodetector (QWIP) focal plane array (FPA) technology. Based on...

  1. Strength Measurements in Acute Hamstring Injuries: Intertester Reliability and Prognostic Value of Handheld Dynamometry

    NARCIS (Netherlands)

    Reurink, Gustaaf; Goudswaard, Gert Jan; Moen, Maarten H.; Tol, Johannes L.; Verhaar, Jan A. N.; Weir, Adam

    2016-01-01

    Study Design Cohort study, repeated measures. Background Although hamstring strength measurements are used for assessing prognosis and monitoring recovery after hamstring injury, their actual clinical relevance has not been established. Handheld dynamometry (HHD) is a commonly used method of

  2. Discrimination of Pigments of Microalgae, Bacteria and Yeasts Using Lightweight Handheld Raman Spectrometers: Prospects for Astrobiology

    Science.gov (United States)

    Jehlicka, J.; Osterrothova, K.; Nedbalova, L.; Gunde-Cimerman, N.; Oren, A.

    2014-06-01

    Handheld Raman instrumentation with 532 nm lasers can be used to distinguish carotenoids of autotrophic microalgae, purple sulfur bacteria, halophilic Archaea and pigmented yeasts. Pigments are proposed as biomarkers for astrobiology of Mars.

  3. Reusable Handheld Electrolytes and Lab Technology for Humans (rHEALTH Sensor), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of rHEALTH sensor is a universal handheld sensor that can provide rapid, low-cost complete blood count (CBC) with differential, electrolyte analysis, and...

  4. Reusable Handheld Electrolytes and Lab Technology for Humans (rHEALTH Sensor), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of the rHEALTH sensor is to provide rapid, low-cost, handheld complete blood count (CBC), cell differential counts, electrolyte measurements, and other lab...

  5. Handheld low-temperature plasma probe for portable "point-and-shoot" ambient ionization mass spectrometry.

    Science.gov (United States)

    Wiley, Joshua S; Shelley, Jacob T; Cooks, R Graham

    2013-07-16

    We describe a handheld, wireless low-temperature plasma (LTP) ambient ionization source and its performance on a benchtop and a miniature mass spectrometer. The source, which is inexpensive to build and operate, is battery-powered and utilizes miniature helium cylinders or air as the discharge gas. Comparison of a conventional, large-scale LTP source against the handheld LTP source, which uses less helium and power than the large-scale version, revealed that the handheld source had similar or slightly better analytical performance. Another advantage of the handheld LTP source is the ability to quickly interrogate a gaseous, liquid, or solid sample without requiring any setup time. A small, 7.4-V Li-polymer battery is able to sustain plasma for 2 h continuously, while the miniature helium cylinder supplies gas flow for approximately 8 continuous hours. Long-distance ion transfer was achieved for distances up to 1 m.

  6. Handheld Nonlinear Detection of Delamination and Intrusion Faults in Composites, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In Phase I of the SBIR program, LEEOAT Company will develop a hand-held high-resolution ultrasonic nonlinear imager for non-destructive inspection (NDI) of...

  7. Into the Wild: Neuroergonomic Differentiation of Hand-Held and Augmented Reality Wearable Displays during Outdoor Navigation with Functional Near Infrared Spectroscopy.

    Science.gov (United States)

    McKendrick, Ryan; Parasuraman, Raja; Murtza, Rabia; Formwalt, Alice; Baccus, Wendy; Paczynski, Martin; Ayaz, Hasan

    2016-01-01

    Highly mobile computing devices promise to improve quality of life, productivity, and performance. Increased situation awareness and reduced mental workload are two potential means by which this can be accomplished. However, it is difficult to measure these concepts in the "wild". We employed ultra-portable battery operated and wireless functional near infrared spectroscopy (fNIRS) to non-invasively measure hemodynamic changes in the brain's Prefrontal cortex (PFC). Measurements were taken during navigation of a college campus with either a hand-held display, or an Augmented reality wearable display (ARWD). Hemodynamic measures were also paired with secondary tasks of visual perception and auditory working memory to provide behavioral assessment of situation awareness and mental workload. Navigating with an augmented reality wearable display produced the least workload during the auditory working memory task, and a trend for improved situation awareness in our measures of prefrontal hemodynamics. The hemodynamics associated with errors were also different between the two devices. Errors with an augmented reality wearable display were associated with increased prefrontal activity and the opposite was observed for the hand-held display. This suggests that the cognitive mechanisms underlying errors between the two devices differ. These findings show fNIRS is a valuable tool for assessing new technology in ecologically valid settings and that ARWDs offer benefits with regards to mental workload while navigating, and potentially superior situation awareness with improved display design.

  8. English language learners' reading self-efficacy and achievement using 1:1 mobile learning devices

    OpenAIRE

    Walters, Jennifer L.

    2012-01-01

    Handheld technology devices allow users to be mobile and access the Internet, personal data, and third-party content applications in many different environments at the users' convenience. The explosion of these mobile learning devices around the globe has led adults to value them for communication, productivity, and learning. Outside of the school setting, many adolescents and children have access to, or own mobile devices. The use of these individual devices by children on a daily basis in s...

  9. Age influence on attitudes of office workers faced with new computerized technologies: a questionnaire analysis.

    Science.gov (United States)

    Marquié, J C; Thon, B; Baracat, B

    1994-06-01

    The study of Bue and Gollac (1988) provided evidence that a significantly lower proportion of workers aged 45 years and over make use of computer technology compared with younger ones. The aim of the present survey was to explain this fact by a more intensive analysis of the older workers' attitude with respect to the computerization of work situations in relation to other individual and organizational factors. Six hundred and twenty office workers from 18 to 70 years old, either users or non-users of computerized devices, were asked to complete a questionnaire. The questions allowed the assessment of various aspects of the workers' current situation, such as the computer training they had received, the degree of consultation they were subjected to during the computerization process, their representation of the effects of these new technologies on working conditions and employment, the rate of use of new technologies outside the work context, and the perceived usefulness of computers for their own work. The analysis of the questionnaire revealed that as long as the step towards using computer tools, even minimally, has not been taken, then attitudes with respect to computerization are on the whole not very positive and are a source of anxiety for many workers. Age, and even more, seniority in the department, increase such negative representations. The effects of age and seniority were also found among users, as well as the effects of other factors such as qualification, education level, type and rate of computer use, and size of the firm. For the older workers, the expectation of less positive consequences for their career, or even the fear that computerization might be accompanied by threats to their own employment and the less clear knowledge of how computers operate, appeared to account for a significant part of the observed age and seniority differences in attitudes. Although the difference in the amount of computer training between age groups was smaller than

  10. Who’s That Girl? Handheld Augmented Reality for Printed Photo Books

    OpenAIRE

    Henze , Niels; Boll , Susanne

    2011-01-01

    Part 1: Long and Short Papers; International audience; Augmented reality on mobile phones has recently made major progress. Lightweight, markerless object recognition and tracking makes handheld Augmented Reality feasible for new application domains. As this field is technology driven the interface design has mostly been neglected. In this paper we investigate visualization techniques for augmenting printed documents using handheld Augmented Reality. We selected the augmentation of printed ph...

  11. Fusing Open Source Intelligence and Handheld Situational Awareness - Benghazi Case Study

    Science.gov (United States)

    2014-10-01

    1 DM-0001694 Fusing Open Source Intelligence and Handheld Situational Awareness Benghazi Case Study Jeff Boleng, PhD Marc Novakouski Gene...command and control element at the CIA compound that would have been monitoring OSINT and other sources of intelligence before the attack and... Source Intelligence and Handheld Situational Awareness - Benghazi Case Study 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6

  12. Handheld mechanical nociceptive threshold testing in dairy cows - intra-individual variation, inter-observer agreement and variation over time.

    Science.gov (United States)

    Raundal, Peter M; Andersen, Pia H; Toft, Nils; Forkman, Björn; Munksgaard, Lene; Herskin, Mette S

    2014-11-01

    To examine the use of handheld methodology to assess mechanical nociceptive threshold (MNT) on cows kept loose-housed. Prospective randomized partial cross-over experimental study. A one-factor (test day) design was used to evaluate MNT over time. One hundred and fifteen healthy, loose-housed Danish Holstein cattle. We evaluated intra-individual variation, inter-observer agreement and variation over time of MNT using two handheld devices and two stimulation sites. Mechanical, ramped stimulations were performed with an algometer (6.5 mm diameter steel probe, 0-10.0 kgf) or an electronic von Frey device (plastic tip with diameter 0.8 mm, 0-1000 gf). Each cow received 5-6 consecutive stimulations within a 2 × 5 cm skin area on the dorsal or lateral aspect of the left third metatarsus until an avoidance reaction occurred. We investigated the difference in precision [expressed as coefficient of variation (CV)] between the combinations of devices and stimulation sites. The inter-observer agreement and the difference in MNT between test day 1, 3, 7, 10 and 24 were investigated for selected combinations. Data were analysed in mixed models and Bland-Altman as relevant. The CVs did not differ [range 0.34-0.52 (p = 0.1)]. Difference between observers (95% limits) was 0.2 kgf (2.8) and 4 gf (369) for the algometer and von Frey device, respectively. Mechanical nociceptive threshold increased from 361 on test day one to 495 gf on test day 24 (p < 0.01). All methods showed a high degree of intra-individual variation, and no combination of device and stimulation site showed superior precision. Mean difference between observers was low, and MNT was not consistent over time. Further development of the methods is required before they can be used in research to investigate possible relations between claw lesions and hyperalgesia. © 2014 The Authors Veterinary Anaesthesia and Analgesia published by John Wiley & Sons Ltd on behalf of Association of Veterinary Anaesthetists and the

  13. Use of Electronic Hand-held Devices for Collection of Savannah River Site Environmental Data - 13329

    Energy Technology Data Exchange (ETDEWEB)

    Marberry, Hugh [SRNS Savannah River Site 730-4B Room 3043 Aiken, SC 29808 (United States); Moore, Winston [SRNS Savannah River Site 735B Room 116 Aiken, SC 29808 (United States)

    2013-07-01

    Savannah River Nuclear Solutions has begun using Xplore Tablet PC's to collect data in the field for soil samples, groundwater samples, air samples and round sheets at the Savannah River Site (SRS). EPA guidelines for groundwater sampling are incorporated into the application to ensure the sample technician follows the proper protocol. The sample technician is guided through the process for sampling and round sheet data collection by a series of menus and input boxes. Field measurements and well stabilization information are entered into the tablet for uploading into Environmental Restoration Data Management System (ERDMS). The process helps to eliminate input errors and provides data integrity. A soil sample technician has the ability to collect information about location of sample, field parameter, describe the soil sample, print bottle labels, and print chain of custody for the sample that they have collected. An air sample technician has the ability to provide flow, pressure, hours of operation, print bottle labels and chain of custody for samples they collect. Round sheets are collected using the information provided in the various procedures. The data are collected and uploaded into ERDMS. The equipment used is weather proof and hardened for the field use. Global Positioning System (GPS) capabilities are integrated into the applications to provide the location where samples were collected and to help sample technicians locate wells that are not visited often. (authors)

  14. 77 FR 32996 - Certain Handheld Electronic Computing Devices, Related Software, and Components Thereof...

    Science.gov (United States)

    2012-06-04

    ... CONTACT: Clint Gerdine, Esq., Office of the General Counsel, U.S. International Trade Commission, 500 E... business hours (8:45 a.m. to 5:15 p.m.) in the Office of the Secretary, U.S. International Trade Commission... instituted this investigation on April 25, 2011, based on a complaint filed by Microsoft Corporation...

  15. A Practical Decision Guide for Integrating Digital Applications and Handheld Devices into Advanced Individual Training

    Science.gov (United States)

    2013-07-01

    Experiential learning . Experiential learning was defined by Kolb (1984) as “the process whereby knowledge is created through the transformation...be seen as an extension of constructivism. Kolb’s Experiential Learning Theory proposed that cycles of action, feedback, reflection, adaption, and...instruction or guidance. A corresponding Learning Styles Inventory was developed to assess orientation toward experiential learning ( Kolb , 1976). However

  16. Screening for diabetic cardiac autonomic neuropathy using a new handheld device

    DEFF Research Database (Denmark)

    Gulichsen, Elisabeth; Fleischer, Jesper; Ejskjaer, Niels

    2012-01-01

    Cardiac autonomic neuropathy (CAN) is a serious complication of longstanding diabetes and is associated with an increased morbidity and reduced quality of life in patients with diabetes. The present study evaluated the prevalence of CAN diagnosed by reduced heart rate variability (HRV) using a ne...

  17. An Empirical Study on Operator Interface Design for Handheld Devices to Control Micro Aerial Vehicles

    Science.gov (United States)

    2010-10-01

    other types of GUIs were developed on Sony’s PlayStation Portable (PSP) and Nokia Internet Tablet (Haylock, 2008, Hou, et al., 2009). Due to the...enabled the MAV to fly straight at a constant speed, and the Reset button restarts the mission if failed . The user was able to designate waypoints in...feedback (display) lag. This is likely the reason why the simultaneous display mode provided significantly better SA than the sequential display

  18. Use of Electronic Hand-held Devices for Collection of Savannah River Site Environmental Data - 13329

    International Nuclear Information System (INIS)

    Marberry, Hugh; Moore, Winston

    2013-01-01

    Savannah River Nuclear Solutions has begun using Xplore Tablet PC's to collect data in the field for soil samples, groundwater samples, air samples and round sheets at the Savannah River Site (SRS). EPA guidelines for groundwater sampling are incorporated into the application to ensure the sample technician follows the proper protocol. The sample technician is guided through the process for sampling and round sheet data collection by a series of menus and input boxes. Field measurements and well stabilization information are entered into the tablet for uploading into Environmental Restoration Data Management System (ERDMS). The process helps to eliminate input errors and provides data integrity. A soil sample technician has the ability to collect information about location of sample, field parameter, describe the soil sample, print bottle labels, and print chain of custody for the sample that they have collected. An air sample technician has the ability to provide flow, pressure, hours of operation, print bottle labels and chain of custody for samples they collect. Round sheets are collected using the information provided in the various procedures. The data are collected and uploaded into ERDMS. The equipment used is weather proof and hardened for the field use. Global Positioning System (GPS) capabilities are integrated into the applications to provide the location where samples were collected and to help sample technicians locate wells that are not visited often. (authors)

  19. Improving car passengers' comfort and experience by supporting the use of handheld devices

    NARCIS (Netherlands)

    Veen, S.A.T. van; Hiemstra-van Mastrigt, S.; Kamp, I.; Vink, P.

    2014-01-01

    Background: There is a demand for interiors to support other activities in a car than controlling the vehicle. Currently, this is the case for the car passengers and-in the future-autonomous driving cars will also facilitate drivers to perform other activities. One of these activities is working

  20. Improving car passengers' comfort and experience by supporting the use of handheld devices

    NARCIS (Netherlands)

    Van Veen, S.A.T.; Van Mastrigt, S.; Kamp, I.; Vink, P.

    2014-01-01

    BACKGROUND: There is a demand for interiors to support other activities in a car than controlling the vehicle. Currently, this is the case for the car passengers and – in the future – autonomous driving cars will also facilitate drivers to perform other activities. One of these activities is working

  1. Shock Analysis Method for Systematic Performance Evaluation of Component Embedded in Handheld Electronic Devices

    Directory of Open Access Journals (Sweden)

    C.S. Chin

    2006-01-01

    Full Text Available It is important to identify the robustness of product (or embedded component inside the product against shock due to free drop. With the increasing mobile and fast-paced lifestyle of the average consumer, much is required of the products; such as consumers expect mobile products to continue to operate after drop impact. Since free drop test is commonly used to evaluate the robustness of small component embedded in MP3 player, it is difficult to produce a repeatable shock reading due to highly uncontrolled orientation during the impact on ground. Hence attention has been focus on shock table testing, which produces a higher repeatable result. But it failed to demonstrate the actual shock with the presence of rotational movement due to free drop and also it suffers from a similar limitation of repeatability. From drop to drop, shock tables can vary about ± 5% in velocity change but suitable for making a consistent tracking the product improvement.

  2. Preliminary study for the personal handheld device based snoring detection in ordinary sleep situation.

    Science.gov (United States)

    Shin, Hangsik; Choi, Wangrim; Kim, Yi-gon; Cho, Jaegeol

    2014-01-01

    Snoring is one of the representative phenomena of the sleep disorder and detection of snoring is quite important for improving quality of daily human life. The purpose of this research is to define the noises of the ordinary sleep situation and to find its characteristics as a preliminary research of snoring detection. Differently from previous snoring researches, we use a built-in sound recording system of Smartphone for practical use in ordinary sleep condition, and recording was carried out in a general private bedroom. Especially, we designed the experimental protocol, including the various noises could be frequently occurred during sleep such as cough, music, talking, alarm, door open/close, fan, radio and footstep to make closer to the actual sleep circumstance. The sound data set was recorded during actual sleep from 10 normal subjects. Totally 44 snoring data set and 75-noise dataset is acquired and analyzed.

  3. Validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt.

    Science.gov (United States)

    Aramaki, Hidefumi; Katoh, Munenori; Hiiragi, Yukinobu; Kawasaki, Tsubasa; Kurihara, Tomohisa; Ohmi, Yorikatsu

    2016-07-01

    [Purpose] This study aimed to investigate the relatedness, reliability, and validity of isometric muscle strength measurements of hip abduction and abduction with an external hip rotation in a bent-hip position using a handheld dynamometer with a belt. [Subjects and Methods] Twenty healthy young adults, with a mean age of 21.5 ± 0.6 years were included. Isometric hip muscle strength in the subjects' right legs was measured under two posture positions using two devices: a handheld dynamometer with a belt and an isokinetic dynamometer. Reliability was evaluated using an intra-class correlation coefficient (ICC); relatedness and validity were evaluated using Pearson's product moment correlation coefficient. Differences in measurements of devices were assessed by two-way ANOVA. [Results] ICC (1, 1) was ≥0.9; significant positive correlations in measurements were found between the two devices under both conditions. No main effect was found between the measurement values. [Conclusion] Our findings revealed that there was relatedness, reliability, and validity of this method for isometric muscle strength measurements using a handheld dynamometer with a belt.

  4. Attentionally splitting the mass distribution of hand-held rods.

    Science.gov (United States)

    Burton, G; Turvey, M T

    1991-08-01

    Two experiments on the length-perception capabilities of effortful or dynamic touch differed only in terms of what the subject intended to perceive, while experimental conditions and apparatus were held constant. In each trial, a visually occluded rod was held as still as possible by the subject at an intermediate position. For two thirds of the trials, a weight was attached to the rod above or below the hand. In Experiment 1, in which the subject's task was to perceive the distance reachable with the portion of the rod forward of the hand, perceived extent was a function of the first moment of the mass distribution associated with the forward portion of the rod, and indifferent to the first moment of the entire rod. In Experiment 2, in which the task was to perceive the distance reachable with the entire rod if it was held at an end, the pattern of results was reversed. These results indicate the capability of selective sensitivity to different aspects of a hand-held object's mass distribution, without the possibility of differential exploration specific to these two tasks. Results are discussed in relation to possible roles of differential information, intention, and self-organization in the explanations of selective perceptual abilities.

  5. Data-Acquisition Systems for Fusion Devices

    NARCIS (Netherlands)

    van Haren, P. C.; Oomens, N. A.

    1993-01-01

    During the last two decades, computerized data acquisition systems (DASs) have been applied at magnetic confinement fusion devices. Present-day data acquisition is done by means of distributed computer systems and transient recorders in CAMAC systems. The development of DASs has been technology

  6. Ultrasonic and computerized tomographic semiotics of cholelithiasis

    International Nuclear Information System (INIS)

    Kishkovskij, A.N.; Kuznetsov, S.V.; Fadeev, V.D.

    1986-01-01

    Altogether 447 patients with suspected cholelithiasis were examined by means of routine X-ray methods, ultrasound (US) and computerized tomography (CT).Of them in 104 (23.3%) chole- and/or choledocholithiasis were later confirmed. An US and CT-picture of the biliferous tracts in health were described.In cholelithiasis during US examination echogenic concrements producing a stable acoustic shadow were defined in the gall bladder cavity and/or in the biliferous ducts. A study was made of the features of the US picture with relation to size, quantity, echodensity and grouping of concrements in the biliferous ducts. CT-symptomatology of cholelithiasis was described

  7. Computerized tomography in radiodiagnosis of pneumonia

    International Nuclear Information System (INIS)

    Degtyareva, I.A.; Mamaev, V.V.; Savchenko, A.P.

    1989-01-01

    Experience in the use of computerized tomography (CT) in combined radiodiagnosis of pneumonia was analysed. It has been concluded that CT objectively reflects morphological inflammatory changes and permits their all-round assessment over time. The diagnosis of pneumonia in CT is based on classical x-ray symptoms. As compared to survery radiography CT reveals symptoms of pneumonia to the full at earlier stages. CT is an important additional method of investigation of inflammatory pulmonary diseases but it should not be used separately without survey radiography. In a majority of cases when CT is performed there is no need in x-ray tomography

  8. Visualization in the age of computerization

    CERN Document Server

    Carusi, Annamaria; Webmoor, Timothy; Woolgar, Steve

    2014-01-01

    Digitalization and computerization are now pervasive in science. This has deep consequences for our understanding of scientific knowledge and of the scientific process, and challenges longstanding assumptions and traditional frameworks of thinking of scientific knowledge. Digital media and computational processes challenge our conception of the way in which perception and cognition work in science, of the objectivity of science, and the nature of scientific objects. They bring about new relationships between science, art and other visual media, and new ways of practicing science and organizing

  9. Development of a computerized tomographic system

    International Nuclear Information System (INIS)

    Borges, J.C.; Santos, C.A.C.

    1986-01-01

    The Nuclear Instrumentation Laboratory at COPPE/UFRJ has been developing techniques for detection and applications of nuclear radiations. A lot of research work has been done and resulted in several M.Sc. and D.Sc. thesis, concerning subjects like neutrongraphy, gammagraphy, image reconstruction, special detectors, etc. Recent progress and multiple applications of the computerized tomography to medical and industrial non-destructive tests, pushed the Laboratory to a vast program in this field of research. In this paper, we report what has been done and the results obtained. (Author) [pt

  10. Computerized tomography in diagnosis of cerebrocranial injury

    International Nuclear Information System (INIS)

    Kornienko, V.N.; Vasin, N.Ya.; Kuz'menko, V.A.

    1987-01-01

    The method of computerized tomographical examination are presented. Th KT-characters of concussion of the brain, its contusion of different severity, compressions in case of traumatic intracranial hematomas, contusion injuries, brain edema and different aftereffects of cerebrocranial injury are given. On the basis of comparison of the data of clinical and KT examination the dynamics of intracranial traumatic injuries in the course of treatment is described. The problems of therapeutic and surgical tactics depending on the degree and form of intracranial structure injuries and the phase of clinical course of posttraumatic process are discussed

  11. Computerized abdominal tomography in Wilson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchikura, Keiko; Ogawa, Teruyuki; Nakajima, Akihisa; Ono, Yasuhiko

    1986-05-01

    Cranial and abdominal computerized tomography (CT) was performed in a 10-year-old boy with Wilson's disease complicated by liver cirrhosis. Abdominal CT showed diffuse high density areas over the whole part of the liver propably due to copper sediments, although there was no abnormal cranial CT findings. Decreased high density area of the liver was seen 60 days after the administration of D-penicillamine, suggesting the excretion of copper from the liver. Abdominal CT, as well as cranial CT, may be of help to diagnose Wilson's disease and evaluate therapeutic effects. (Namekawa, K.).

  12. Evidence Considerations for Mobile Devices in the Occupational Therapy Process

    Directory of Open Access Journals (Sweden)

    Kelly Erickson

    2015-04-01

    Full Text Available Mobile app-based device utilization, including smartphones and handheld tablets, suggests a need to evaluate evidence to guide selection and implementation of these devices in the occupational therapy process. The purpose of the research was to explore the current body of evidence in relation to mobile app-based devices and to identify factors in the use of these devices throughout the occupational therapy process. Following review of available occupational therapy profession guidelines, assistive technology literature, and available mobile device research, practitioners using mobile app-based devices in occupational therapy should consider three areas: client needs, practitioner competence, and device factors. The purpose of this guideline is to identify factors in the selection and use of mobile app-based devices throughout the occupational therapy process based on available evidence. Considerations for mobile device implementation during the occupational therapy process is addressed, including evaluating outcomes needs, matching device with the client, and identifying support needs of the client.

  13. Integrated optical detection of autonomous capillary microfluidic immunoassays:a hand-held point-of-care prototype.

    Science.gov (United States)

    Novo, P; Chu, V; Conde, J P

    2014-07-15

    The miniaturization of biosensors using microfluidics has potential in enabling the development of point-of-care devices, with the added advantages of reduced time and cost of analysis with limits-of-detection comparable to those obtained through traditional laboratory techniques. Interfacing microfluidic devices with the external world can be difficult especially in aspects involving fluid handling and the need for simple sample insertion that avoids special equipment or trained personnel. In this work we present a point-of-care prototype system by integrating capillary microfluidics with a microfabricated photodiode array and electronic instrumentation into a hand-held unit. The capillary microfluidic device is capable of autonomous and sequential fluid flow, including control of the average fluid velocity at any given point of the analysis. To demonstrate the functionality of the prototype, a model chemiluminescence ELISA was performed. The performance of the integrated optical detection in the point-of-care prototype is equal to that obtained with traditional bench-top instrumentation. The photodiode signals were acquired, displayed and processed by a simple graphical user interface using a computer connected to the microcontroller through USB. The prototype performed integrated chemiluminescence ELISA detection in about 15 min with a limit-of-detection of ≈2 nM with an antibody-antigen affinity constant of ≈2×10(7) M(-1). Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Modernizing computerized nuclear material accounting systems

    International Nuclear Information System (INIS)

    Erkkila, B.H.; Claborn, J.

    1995-01-01

    DOE Orders and draft orders for nuclear material control and accountability address a complete material control and accountability (MC and A) program for all DOE contractors processing, using, or storing nuclear materials. A critical element of an MC and A program is the accounting system used to track and record all inventories of nuclear material and movements of materials in those inventories. Most DOE facilities use computerized accounting systems to facilitate the task of accounting for all their inventory of nuclear materials. Many facilities still use a mixture of a manual paper system with a computerized system. Also, facilities may use multiple systems to support information needed for MC and A. For real-time accounting it is desirable to implement a single integrated data base management system for a variety of users. In addition to accountability needs, waste management, material management, and production operations must be supported. Information in these systems can also support criticality safety and other safety issues. Modern networked microcomputers provide extensive processing and reporting capabilities that single mainframe computer systems struggle with. This paper describes an approach being developed at Los Alamos to address these problems

  15. Patient surface doses in computerized tomography examinations

    International Nuclear Information System (INIS)

    Vekic, B; Kovacevic, S.; Ranogajec-Komor, M.; Duvnjak, N.; Marusic, P.; Anic, P.; Dolencic, P.

    1996-01-01

    The diagnostic value of computerized tomography has increased due to very rapid technical advances in both equipment and techniques. When the CT scanners were introduced, a significant problem for the specification of the radiation dose imparted to the patient undergoing CT examination has been created. In CT, the conditions of exposure are quite different from those in conventional X-ray imaging. CT procedure involves the continuous tomography of thin layers. Some of these layers touch each other while others overlap. The radiation doses received by patients can vary considerably. In addition to the radiation from the collimated primary beam, patients are exposed to significant scattered doses in unpredictable amounts. Every effort should be made to keep these doses to a reasonable minimum, without sacrificing the image quality. The aims of this work were to determine the surface doses delivered to various organs of patients during various computerized tomography examinations (head, thorax, kidney, abdomen and pelvis). Particular attention was directed to the precise determination of doses received by the eyes (during CT of head) and gonads (during CT of pelvis and lower abdomen) since these organs can be near or even in the primary X-ray beam

  16. Computerized tomographic in non-destructive testing

    International Nuclear Information System (INIS)

    Lopes, R.T.

    1988-01-01

    The process of computerized tomography has been developed for medical imaging purposes using tomographs with X-ray, and little attention has been given to others possibles applications of technique, because of its cost. As an alternative for the problem, we constructed a Tomographic System (STAC-1), using gamma-rays, for nonmedical applications. In this work we summarize the basic theory of reconstructing images using computerized tomography and we describe the considerations leading to the development of the experimental system. The method of reconstruction image implanted in the system is the filtered backprojection or convolution, with a digital filters system to carried on a pre-filtering in the projections. The experimental system is described, with details of control and the data processing. An alternative and a complementary system, using film as a detector is shown in preliminary form . This thesis discuss and shows the theorical and practical aspects, considered in the construction of the STAC-1, and also its limitations and apllications [pt

  17. A prototype of a computerized patient record.

    Science.gov (United States)

    Adelhard, K; Eckel, R; Hölzel, D; Tretter, W

    1995-01-01

    Computerized medical record systems (CPRS) should present user and problem oriented views of the patient file. Problem lists, clinical course, medication profiles and results of examinations have to be recorded in a computerized patient record. Patient review screens should give a synopsis of the patient data to inform whenever the patient record is opened. Several different types of data have to be stored in a patient record. Qualitative and quantitative measurements, narratives and images are such examples. Therefore, a CPR must also be able to handle these different data types. New methods and concepts appear frequently in medicine. Thus a CPRS must be flexible enough to cope with coming demands. We developed a prototype of a computer based patient record with a graphical user interface on a SUN workstation. The basis of the system are a dynamic data dictionary, an interpreter language and a large set of basic functions. This approach gives optimal flexibility to the system. A lot of different data types are already supported. Extensions are easily possible. There is also almost no limit concerning the number of medical concepts that can be handled by our prototype. Several applications were built on this platform. Some of them are presented to exemplify the patient and problem oriented handling of the CPR.

  18. Cellphone-based hand-held microplate reader for point-of-care ELISA testing (Conference Presentation)

    Science.gov (United States)

    Berg, Brandon; Cortazar, Bingen; Tseng, Derek; Ozkan, Haydar; Feng, Steve; Wei, Qingshan; Chan, Raymond Y.; Burbano, Jordi; Farooqui, Qamar; Lewinski, Michael; Di Carlo, Dino; Garner, Omai B.; Ozcan, Aydogan

    2016-03-01

    Enzyme-linked immunosorbent assay (ELISA) in a microplate format has been a gold standard first-line clinical test for diagnosis of various diseases including infectious diseases. However, this technology requires a relatively large and expensive multi-well scanning spectrophotometer to read and quantify the signal from each well, hindering its implementation in resource-limited-settings. Here, we demonstrate a cost-effective and handheld smartphone-based colorimetric microplate reader for rapid digitization and quantification of immunoserology-related ELISA tests in a conventional 96-well plate format at the point of care (POC). This device consists of a bundle of 96 optical fibers to collect the transmitted light from each well of the microplate and direct all the transmission signals from the wells onto the camera of the mobile-phone. Captured images are then transmitted to a remote server through a custom-designed app, and both quantitative and qualitative diagnostic results are returned back to the user within ~1 minute per 96-well plate by using a machine learning algorithm. We tested this mobile-phone based micro-plate reader in a clinical microbiology lab using FDA-approved mumps IgG, measles IgG, and herpes simplex virus IgG (HSV-1 and HSV-2) ELISA tests on 1138 remnant patient samples (roughly 50% training and 50% testing), and achieved an overall accuracy of ~99% or higher for each ELISA test. This handheld and cost-effective platform could be immediately useful for large-scale vaccination monitoring in low-infrastructure settings, and also for other high-throughput disease screening applications at POC.

  19. Portable Hand-Held Electrochemical Sensor for the Transuranics

    Energy Technology Data Exchange (ETDEWEB)

    Dale D. Russell, William B. Knowlton, Ph.D.; Russel Hertzog, Ph.D

    2005-11-25

    sensitive detector for uranium. Millimeter scale electrodes, operated by a hand-held instrument assembled in this lab and operated in the voltammetric mode, were transported to the DOE-Nevada test site (Las Vegas, NV) where field detection and quantitation of plutonium, uranium, and a mixture of these two elements was also demonstrated. Several probe designs were prepared, built and tested including probes with movable protective windows. A miniature, battery powered potentiostat was designed, built and demonstrated for use in a hand-held field portable instrument. This work was performed largely by undergraduates who gained valuable research experience, and many of them have continued on to graduate schools. In addition, they all gained exposure to and appreciation for national security research, in particular non-proliferation research. Four graduate students participated and one earned the MS degree on this project.

  20. Evaluation and analytical validation of a handheld digital refractometer for urine specific gravity measurement

    Directory of Open Access Journals (Sweden)

    Sara P. Wyness

    2016-08-01

    Full Text Available Objectives: Refractometers are commonly used to determine urine specific gravity (SG in the assessment of hydration status and urine specimen validity testing. Few comprehensive performance evaluations are available demonstrating refractometer capability from a clinical laboratory perspective. The objective of this study was therefore to conduct an analytical validation of a handheld digital refractometer used for human urine SG testing. Design and methods: A MISCO Palm Abbe™ refractometer was used for all experiments, including device familiarization, carryover, precision, accuracy, linearity, analytical sensitivity, evaluation of potential substances which contribute to SG (i.e. “interference”, and reference interval evaluation. A manual refractometer, urine osmometer, and a solute score (sum of urine chloride, creatinine, glucose, potassium, sodium, total protein, and urea nitrogen; all in mg/dL were used as comparative methods for accuracy assessment. Results: Significant carryover was not observed. A wash step was still included as good laboratory practice. Low imprecision (%CV, <0.01 was demonstrated using low and high QC material. Accuracy studies showed strong correlation to manual refractometry. Linear correlation was also demonstrated between SG, osmolality, and solute score. Linearity of Palm Abbe performance was verified with observed error of ≤0.1%. Increases in SG were observed with increasing concentrations of albumin, creatinine, glucose, hemoglobin, sodium chloride, and urea. Transference of a previously published urine SG reference interval of 1.0020–1.0300 was validated. Conclusions: The Palm Abbe digital refractometer was a fast, simple, and accurate way to measure urine SG. Analytical validity was confirmed by the present experiments. Keywords: Specific gravity, Osmolality, Digital refractometry, Hydration, Sports medicine, Urine drug testing, Urine adulteration

  1. Handheld echocardiography during hospitalization for acute myocardial infarction.

    Science.gov (United States)

    Cullen, Michael W; Geske, Jeffrey B; Anavekar, Nandan S; Askew, J Wells; Lewis, Bradley R; Oh, Jae K

    2017-11-01

    Handheld echocardiography (HHE) is concordant with standard transthoracic echocardiography (TTE) in a variety of settings but has not been thoroughly compared to traditional TTE in patients with acute myocardial infarction (AMI). Completed by experienced operators, HHE provides accurate diagnostic capabilities compared with standard TTE in AMI patients. This study prospectively enrolled patients admitted to the coronary care unit with AMI. Experienced sonographers performed HHE with a V-scan. All patients underwent clinical TTE. Each HHE was interpreted by 2 experts blinded to standard TTE. Agreement was assessed with κ statistics and concordance correlation coefficients. Analysis included 82 patients (mean age, 66 years; 74% male). On standard TTE, mean left ventricular (LV) ejection fraction was 46%. Correlation coefficients between HHE and TTE were 0.75 (95% confidence interval: 0.66 to 0.82) for LV ejection fraction and 0.69 (95% confidence interval: 0.58 to 0.77) for wall motion score index. The κ statistics ranged from 0.47 to 0.56 for LV enlargement, 0.55 to 0.79 for mitral regurgitation, and 0.44 to 0.57 for inferior vena cava dilatation. The κ statistics were highest for the anterior (0.81) and septal (0.71) apex and lowest for the mid inferolateral (0.36) and basal inferoseptal (0.36) walls. In patients with AMI, HHE and standard TTE demonstrate good correlation for LV function and wall motion. Agreement was less robust for structural abnormalities and specific wall segments. In experienced hands, HHE can provide a focused assessment of LV function in patients hospitalized with AMI; however, HHE should not substitute for comprehensive TTE. © 2017 Wiley Periodicals, Inc.

  2. Handheld echocardiography versus auscultation for detection of rheumatic heart disease.

    Science.gov (United States)

    Godown, Justin; Lu, Jimmy C; Beaton, Andrea; Sable, Craig; Mirembe, Grace; Sanya, Richard; Aliku, Twalib; Yu, Sunkyung; Lwabi, Peter; Webb, Catherine L; Ensing, Gregory J

    2015-04-01

    Rheumatic heart disease (RHD) remains a major public health concern in developing countries, and routine screening has the potential to improve outcomes. Standard portable echocardiography (STAND) is far more sensitive than auscultation for the detection of RHD but remains cost-prohibitive in resource-limited settings. Handheld echocardiography (HAND) is a lower-cost alternative. The purpose of this study was to assess the incremental value of HAND over auscultation to identify RHD. RHD screening was completed for schoolchildren in Gulu, Uganda, by using STAND performed by experienced echocardiographers. Any child with mitral or aortic regurgitation or stenosis plus a randomly selected group of children with normal STAND findings underwent HAND and auscultation. STAND and HAND studies were interpreted by 6 experienced cardiologists using the 2012 World Heart Federation criteria. Sensitivity and specificity of HAND and auscultation for the detection of RHD and pathologic mitral or aortic regurgitation were calculated by using STAND as the gold standard. Of 4773 children who underwent screening with STAND, a subgroup of 1317 children underwent HAND and auscultation. Auscultation had uniformly poor sensitivity for the detection of RHD or valve disease. Sensitivity was significantly improved by using HAND compared with auscultation for the detection of definite RHD (97.8% vs 22.2%), borderline or definite RHD (78.4% vs 16.4%), and pathologic aortic insufficiency (81.8% vs 13.6%). Auscultation alone is a poor screening test for RHD. HAND significantly improves detection of RHD and may be a cost-effective screening strategy for RHD in resource-limited settings. Copyright © 2015 by the American Academy of Pediatrics.

  3. Direction-Sensitive Hand-Held Gamma-Ray Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mukhopadhyay, S.

    2012-10-04

    A novel, light-weight, hand-held gamma-ray detector with directional sensitivity is being designed. The detector uses a set of multiple rings around two cylindrical surfaces, which provides precise location of two interaction points on two concentric cylindrical planes, wherefrom the source location can be traced back by back projection and/or Compton imaging technique. The detectors are 2.0 × 2.0 mm europium-doped strontium iodide (SrI2:Eu2+) crystals, whose light output has been measured to exceed 120,000 photons/MeV, making it one of the brightest scintillators in existence. The crystal’s energy resolution, less than 3% at 662 keV, is also excellent, and the response is highly linear over a wide range of gamma-ray energies. The emission of SrI2:Eu2+ is well matched to both photo-multiplier tubes and blue-enhanced silicon photodiodes. The solid-state photomultipliers used in this design (each 2.0 × 2.0 mm) are arrays of active pixel sensors (avalanche photodiodes driven beyond their breakdown voltage in reverse bias); each pixel acts as a binary photon detector, and their summed output is an analog representation of the total photon energy, while the individual pixel accurately defines the point of interaction. A simple back-projection algorithm involving cone-surface mapping is being modeled. The back projection for an event cone is a conical surface defining the possible location of the source. The cone axis is the straight line passing through the first and second interaction points.

  4. Radiographic analysis of body composition by computerized axial tomography

    International Nuclear Information System (INIS)

    Heymsfield, S.B.

    1986-01-01

    Radiographic methods of evaluating body composition have been applied for over five decades. A marked improvement in this approach occurred in the mid-nineteen-seventies with the introduction of computerized axial tomography. High image contrast, cross-sectional imaging and rapid computerized data processing make this technique a sophisticated clinically applicable tool. (author)

  5. Direct coronary and sagittal computerized tomography of the pelvis

    International Nuclear Information System (INIS)

    Maier, W.; Bargon, G.

    1981-01-01

    Whereas quite a number of reports have been published on direct coronary and sagittal computed tomography of the cranium, no extensive experience has been collected on multidimensional computerized tomography of the pelvis. In this article, the authors report on their preliminary experiences in direct approximately sagittal and coronary computerized tomography of the pelvis in a group of 76 patients. (orig.) [de

  6. Computerized tomography in evaluation of the pulmonary hilum

    International Nuclear Information System (INIS)

    Secaf, M.; Ferreira, J.L.N.; Secaf, E.

    1987-01-01

    The use of computerized tomography as a method for evaluating the pulmonary hilum and its application in the diagnosis of endobronchial lesions, hilar masss, contiguous involvement of the mediastinum by hilar mass, and vascular hilar lesions are discussed. A comparative evaluation between conventional tomograms and computerized tomography is presented. (M.A.C.) [pt

  7. Computerized study with 201Tl of the gold thyroid node

    International Nuclear Information System (INIS)

    Palermo, F.; Saitta, B.; Coghetto, F.; Tiberio, M.; Caldato, L.

    1982-01-01

    Because of its physical and potassium-metabolic characteristics 201 Tl is more suitable than 131 Cs for radioisotopic studies of the cold thyroid nodule, with the further diagnostic possibility of quantitatively assessing intranodular behaviour for a specific differentiation among different kinds of neoformations. Using a gamma-camera on line with a computer data processing device, sequential scintiscans were recorded for the first 20-30 min after i.v. administration of 15-20 μCi/kg of radiothallium; delayed sequences were taken at 40-60 min if intranodular uptake appeared. A quantitative appraisal was made of the differential 201 Tl uptake-ratio between nodule and healthy thyroid tissue (density-index) and the multiparameter analysis of thyroid time/activity curves generated on the relative regions of interest (ROIs). This computerized study, in 120 out of 293 patients submitted to this radiothallium test, has shown a) diagnostic agreement between clinical-histological and radioisotopic findings in 76 out of 79 colloid-cystic or degenerative neoformations, in all 16 malignant and in 23 out of 25 hyperplastic benign nodules; b) significant statistical difference of the density-index in solid versus cystic but not between benign and malignant nodules; c) different 201 Tl kinetics behaviour in different kinds of solid thyroid lesions with a satisfactory statistical difference of the radiothallium nodular dissappearance-index. (orig.) [de

  8. The Computerized Table Setting Test for Detecting Unilateral Neglect.

    Directory of Open Access Journals (Sweden)

    Seok Jong Chung

    Full Text Available Patients with unilateral neglect fail to respond normally to stimuli on the left side. To facilitate the evaluation of unilateral spatial neglect, we developed a new application that runs on a tablet device and investigated its feasibility in stroke patients.We made the computerized table setting test (CTST to run on the tablet computer. Forty acute ischemic stroke patients (20 patients with right hemispheric infarction with neglect, 10 patients with right hemispheric infarction without neglect, and 10 patients with left hemispheric infarction and 10 healthy controls were prospectively enrolled to validate the CTST. The test requires subjects to set a table by dragging 12 dishes located below the table on the tablet screen. The horizontal deviation of the 12 dishes from the midline of the table, the selection tendency measured by the sequence of the dish selection, and the elapsed time for table setting were calculated automatically.Parameters measured by the CTST were correlated with the results of conventional neglect tests. The horizontal deviation was significantly higher in patients with right hemispheric infarction with neglect compared with the other groups. The selection tendency and elapsed time also were significantly different in patients with right hemispheric infarction with neglect compared with the left hemispheric infarction and control groups, but were similar to those with right hemispheric infarction without neglect.The CTST is feasible to administer and comparable with conventional neglect tests. This new application may be useful for the initial diagnosis and follow-up of neglect patients.

  9. Can handheld micropower impulse radar technology be used to detect pneumothorax? Initial experience in a European trauma centre.

    Science.gov (United States)

    Albers, C E; Haefeli, P C; Zimmermann, H; de Moya, M; Exadaktylos, A K

    2013-05-01

    Pneumothoraces are a common injury pattern in emergency medicine. Rapid and safe identification can reduce morbidity and mortality. A new handheld, battery powered device, the Pneumoscan (CE 561036, PneumoSonics Inc., Cleveland, OH, USA), using micropower impulse radar (MIR) technology, has recently been introduced in Europe for the rapid and reliable detection of PTX. However, this technology has not yet been tested in trauma patients. This is the first quality control evaluation to report on emergency room performance of a new device used in the trauma setting. This study was performed at a Level I trauma centre in Switzerland. All patients with thoracic trauma and undergoing chest X-ray and CT-scan were eligible for the study. Readings were performed before the chest X-ray and CT scan. The patients had eight lung fields tested (four on each side). All readings with the Pneumoscan were performed by two junior residents in our department who had previously received an instructional tutorial of 15min. The qualitative MIR results were blinded, and stored on the device. We then compared the results of the MIR to those of the clinical examination, chest X-ray and CT-scan. 50 patients were included, with a mean age of 46 (SD 17) years. Seven patients presented with PTX diagnosed by CT; six of these were detected by Pneumoscan, leading to an overall sensitivity of 85.7 (95% confidence interval 42.1-99.6)%. Only two of seven PTX were found during clinical examination and on chest X-ray (sensitivity 28.6 (95% CI 3.7-71.0)%). Of the remaining 43 of 50 patients without PTX, one false-positive PTX was found by the Pneumoscan, resulting in a specificity of 97.7 (95% CI 87.7-99.9)%. The Pneumoscan is an easy to use handheld technology with reliable results. In this series, the sensitivity to detect a PTX by the Pneumoscan was higher than by clinical examination and chest X-ray. Further studies with higher case numbers and a prospective study design are needed to confirm our

  10. Do New Mobile Devices in Enterprises Pose A Serious Security Threat?

    OpenAIRE

    Ali A Altalbe

    2013-01-01

    The purpose of this paper is to introduce a research proposal designed to explore the network securityissues concerning mobile devices protection. Many threats exist and they harm not only computers but handheld devices as well. The mobility of phones and their excessive use make them more vulnerable. The findings suggest a list of protections that can provide high level of security for new mobile devices.

  11. A COMPUTERIZED OPERATOR SUPPORT SYSTEM PROTOTYPE

    Energy Technology Data Exchange (ETDEWEB)

    Thomas A. Ulrich; Roger Lew; Ronald L. Boring; Ken Thomas

    2015-03-01

    A computerized operator support system (COSS) is proposed for use in nuclear power plants to assist control room operators in addressing time-critical plant upsets. A COSS is a collection of technologies to assist operators in monitoring overall plant performance and making timely, informed decisions on appropriate control actions for the projected plant condition. A prototype COSS was developed in order to demonstrate the concept and provide a test bed for further research. The prototype is based on four underlying elements consisting of a digital alarm system, computer-based procedures, piping and instrumentation diagram system representations, and a recommender module for mitigation actions. The initial version of the prototype is now operational at the Idaho National Laboratory using the Human System Simulation Laboratory.

  12. Computerized accountability program is operating - DYMCAS

    International Nuclear Information System (INIS)

    Combs, S.W.; Mee, W.T.

    1983-01-01

    The nuclear materials control and accountability program in the Oak Ridge Y-12 Plant has been placed on a computerized system identified as DYMCAS (Dynamic Special Nuclear Materials Control and Accountability System). The primary gola of the DYMCAS is to assist in detecting the diversion of special nuclear material (SNM). Secondly, the system is expected to assure quality inventory reconciliations both under normal and emergency situations. The system has been installed and was placed on active status in April 1982. Since that time numerous problems have surfaced and been resolved; i.e., delays of input, hardware breakdown, and misunderstandings of needs. An explanation of these problems, including examples and alterations that have made the system workable, are presented

  13. A computerized accountability program is operating - DYMCAS

    International Nuclear Information System (INIS)

    Combs, S.W.; Mee, W.T.

    1983-01-01

    The nuclear materials control and accountability program in the Oak Ridge Y-12 Plant has been placed on a computerized system identified as DYMCAS (Dynamic Special Nuclear Materials Control and Accountability System). The primary goal of the DYMCAS is to assist in detecting the diversion of special nuclear material (SNM). Secondly, the system is expected to assure quality inventory reconciliations both under normal and emergency situations. The system has been installed and was placed on active status in April 1982. Since that time numerous problems have surfaced and been resolved; i.e., delays of input, hardware breakdown, and misunderstandings of needs. An explanation of these problems, including examples and alterations that have made the system workable, are presented

  14. Computerized tomographic scanner with shaped radiation filter

    International Nuclear Information System (INIS)

    Carlson, R.W.; Walters, R.G.

    1981-01-01

    The invention comprises a shaped filter and a filter correction circuitry for computerized tomographic scanners. The shaped filter is a generally u-shaped block of filter material which is adapted to be mounted between the source of radiation and the scan circle. The u-shaped block has a parabolic recess. The filter material may be beryllium, aluminum, sulphur, calcium, titanium, erbium, copper, and compounds including oxides and alloys thereof. The filter correction circuit comprises a first filter correction profile adding circuit for adding a first scaler valve to each intensity valve in a data line. The data line is operated on by a beam hardness correction polynomial. After the beam hardness polynomial correction operation, a second filter correction circuit adds a second filter correction profile consisting of a table of scalor values, one corresponding to each intensity reading in the data line

  15. Computerized tomography findings in nasolacrimal dysfunction

    International Nuclear Information System (INIS)

    Ishida, Toshio; Nakamura, Yasuhisa; Kumagai, Michiasa

    1985-01-01

    We examined 17 cases (22 lesions) with stenosis or obstruction in the lacrimal drainage system with the use of computerized tomography (CT). In idio pathic cases, the site of obstruction was located either in the upper nasolacrimal duct or at the junction of the lacrimal sac and the nasolacrimal duct. In post-traumatic cases, it was located in the lower nasolacrimal duct. The obstructed areas appeared as homogenous in CT image with CT values ranging between +60 and +80. These findings were suggestive of granulation tissue. The stenosed areas appeared, on the other hand, as areas of unequal density. Lacrimal passage appeared to be maintained through the low-density portion. The CT values of the lacrimal sac was around +40 in dacryocystitis and around +20 to +30 other cases. (author)

  16. Organ doses from computerized tomography examinations

    Energy Technology Data Exchange (ETDEWEB)

    Janeczek, J.

    1995-12-31

    Estimates of mean organs doses from five typical computerized tomography (CT) examinations were obtained. Measurements were done using Rando-Alderson anthropomorphic phantom and thermoluminescent dosemeters (TLD). Radiation dose distributions within a phantom has been measured for each examination and results were used for organ dose calculation. Doses to organs specified by ICPR 60 Recommendations were measured for five CT scanners (CT/T8800, CT 9800, CT MAX - made by General Electric; CT 1200 SX - made by Picker; SOMATOM 2 - made by Siemens). Dose distributions from scattered radiation were measured and indicate that scattered radiation dose to thyroid and eye lens can be reduced by proper examination limits setting. The lowest mean organ doses were obtained from CT/T8800 scanner. More advanced scanners using high intensity continuous radiation were giving higher organ doses. (author). 23 refs, 6 figs, 13 tabs.

  17. Computerization of a telescope at secondary education

    Science.gov (United States)

    García Santiago, A.; Martos Jumillas, J.

    2017-03-01

    The work we are presenting in this paper is the computerization of a refractor telescope on an EQ3 type equatorial mount through Arduino. The control of the mount is done via three different interfaces: Stellarium, an Android interface for mobile phones and a second interface for PC made with Processing. The aforementioned work was done by the authors with a double purpose: presenting the interest in astronomy in the Mathematics department, and the development of applications within the subject of Technology in 4th ESO. So, it is a collaborative project between both departments. Except for the telescope and the mount, all the resources we have used can be found in any high school: free software (Guadalinex v9), App Inventor and Processing.The project was carried out under the principle of reducing all possible costs given the economic possibilities of the institution.

  18. Development of computerized risk management tool

    International Nuclear Information System (INIS)

    Kil Yoo Kim; Mee Jung Hwang; Seung Cheol Jang; Sang Hoon Han; Tae Woon Kim

    1997-01-01

    The author describes the kinds of efforts for the development of computerized risk management tool; (1) development of a risk monitor, Risk Monster, (2) improvement of McFarm (Missing Cutsets Finding Algorithm for Risk Monitor) and finally (3) development of reliability database management system, KwDBMan. Risk Monster supports for plant operators and maintenance schedulers to monitor plant risk and to avoid high peak risk by rearranging maintenance work schedule. Improved McFarm significantly improved calculation speed of Risk Monster for the cases of supporting system OOS (Out Of Service). KwDBMan manages event data, generic data and CCF (Common Cause Failure) data to support Risk Monster as well as PSA tool, KIRAP (KAERI Integrated Reliability Analysis Package)

  19. Computerized tomographic evaluation of cerebral cysticercosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bo Young; Lee, Mi Sook; Jeon, Doo Sung; Kim, Hong Soo; Rhee, Hak Song [Precbyterian Medical Center, Chonju (Korea, Republic of)

    1988-08-15

    Cerebral cysticercosis, unfortunately frequent in Korea, is a parastic disease in which man serve as the intermediate host of taenia solium. The larvae have a predilection for the central nervous system and can cause a variety of neurologic symptoms. The authors reviewed 19 cases of surgically proven cerebral cysticercosis and following results were obtained. 1. The most frequent age distribution was 5th and 6th decade and male to female ratio was 14:5. 2. The most frevalent involving site was cerebral parenchyme and following by ventricles. 3. Clinical manifestations were symtom and sign of increased ICP, seizure and focal neurological dificit. 4. It was assumed that computerized tomography was the procedure of choice for the diagnosis of these parasitic brain disease.

  20. Computerized axial tomography in traumatic cervical lesions

    International Nuclear Information System (INIS)

    Koyama, Tsunemaro

    1982-01-01

    Although plain computerized axial tomography cannot routinely demonstrate the spinal cord, it does provide excellent visualization of the bony outline of the spinal canal and vertebral column. So it should be reasonable to use this technique in cases of cervical traumatic disorders. In this paper we presented 10 cases of cervical traumatic lesions; 3 atlanto-axial dislocation, 2 cervical canal stenosis, 3 OPLL, 1 intramedullary hematoma and 1 C 2 -neurinoma. In some patients neurologic deficits were induced by cervical trauma. Bony lesions appeared more adequately deliniated than intraspinal lesions, however, in some cases intramedullary changes could also be demonstrated. The use of metrizamide with high resolution CT-scanner could improve the usefullness of this technique. (author)

  1. Organ doses from computerized tomography examinations

    International Nuclear Information System (INIS)

    Janeczek, J.

    1995-01-01

    Estimates of mean organs doses from five typical computerized tomography (CT) examinations were obtained. Measurements were done using Rando-Alderson anthropomorphic phantom and thermoluminescent dosemeters (TLD). Radiation dose distributions within a phantom has been measured for each examination and results were used for organ dose calculation. Doses to organs specified by ICPR 60 Recommendations were measured for five CT scanners (CT/T8800, CT 9800, CT MAX - made by General Electric; CT 1200 SX - made by Picker; SOMATOM 2 - made by Siemens). Dose distributions from scattered radiation were measured and indicate that scattered radiation dose to thyroid and eye lens can be reduced by proper examination limits setting. The lowest mean organ doses were obtained from CT/T8800 scanner. More advanced scanners using high intensity continuous radiation were giving higher organ doses. (author). 23 refs, 6 figs, 13 tabs

  2. Dose evaluation in diagnostic for computerized tomography

    International Nuclear Information System (INIS)

    Flores, W.; Borges, J.C.; Mota, H.

    1998-01-01

    The patients which are subjected to computerized tomography tests are exposed to relatively high doses given as result doses on organs that are not matter to test. It was realized a dose levels raising in patients subjected to tests by T C, utilizing to measure this magnitude, TLD-100 thermoluminescent dosemeters which were put directly on the patient, in eye regions, thyroid, breast and navel; founding doses fluctuating between 29.10-49.39 mGy in organs examined and dose values between 0.21-29.10 mGy for organs that no matter to test. The applications of ionizing radiations in medicine do not have dose limits, but paying attention to the radiological protection optimization principle, it is recommended the use of clothes to anti-rays protection for zones not examined, getting with this to reduce the level doses as low as possible, without this to diminish the test quality. (Author)

  3. Computerized information management for institutional review boards.

    Science.gov (United States)

    Hood, Maureen N; Gugerty, Brian; Levine, Richard; Ho, Vincent B

    2005-01-01

    The use of human subjects for medical research in most industrialized nations requires the scientific and ethical scrutiny of research proposals by a governing institutional review board (IRB) or its equivalent. As part of their primary charge to protect human subjects, IRBs are responsible for the regulatory oversight of not only the research protocol itself but also the research conduct of the investigators and, if applicable, the funding sponsor. This article will discuss the regulatory requirements for an accurate account of IRB protocols and investigators and present an overview of the general flow of information for an IRB protocol. The current and potential uses of information management systems by IRBs will also be reviewed and accompanied by a discussion of the potential advantages and disadvantages of various computerized information systems for management of clinical research.

  4. Normal anatomical measurements in cervical computerized tomography

    International Nuclear Information System (INIS)

    Zaunbauer, W.; Daepp, S.; Haertel, M.

    1985-01-01

    Radiodiagnostically relevant normal values and variations for measurements of the cervical region, the arithmetical average and the standard deviation were determined from adequate computer tomograms on 60 healthy women and men, aged 20 to 83 years. The sagittal diameter of the prevertebral soft tissue and the lumina of the upper respiratory tract were evaluated at exactly defined levels between the hyoid bone and the incisura jugularis sterni. - The thickness of the aryepiglottic folds, the maximal sagittal and transverse diameters of the thyroid gland and the calibre of the great cervical vessels were defined. - To assess information about laryngeal function in computerized tomography, measurements of distances between the cervical spine and anatomical fixed points of the larynx and hypopharynx were made as well as of the degree of vocal cord movement during normal respiration and phonation. (orig.) [de

  5. Computerized radionuclidic analysis in production facilities

    International Nuclear Information System (INIS)

    Gibbs, A.

    1978-03-01

    The Savannah River Plant Laboratories Department has been using a dual computer system to control all radionuclidic pulse height analyses since 1971. This computerized system analyzes 7000 to 8000 samples per month and has allowed the counting room staff to be reduced from three persons to one person. More reliable process information is being returned to the production facilities and for environmental evaluations and being returned faster, even though the sample load has more than tripled. This information is now more easily retrievable for other evaluations. The computer is also used for mass spectrometer data reduction and for quality control data analysis. The basic system is being expanded by interfacing microcomputers which provide data input from all of the laboratory modules for quality assurance programs

  6. Termination Criteria for Computerized Classification Testing

    Directory of Open Access Journals (Sweden)

    Nathan A. Thompson

    2011-02-01

    Full Text Available Computerized classification testing (CCT is an approach to designing tests with intelligent algorithms, similar to adaptive testing, but specifically designed for the purpose of classifying examinees into categories such as - pass- and - fail.- Like adaptive testing for point estimation of ability, the key component is the termination criterion, namely the algorithm that decides whether to classify the examinee and end the test or to continue and administer another item. This paper applies a newly suggested termination criterion, the generalized likelihood ratio (GLR, to CCT. It also explores the role of the indifference region in the specification of likelihood-ratio based termination criteria, comparing the GLR to the sequential probability ratio test. Results from simulation studies suggest that the GLR is always at least as efficient as existing methods.

  7. Computerized Clinical Decision Support: Contributions from 2015

    Science.gov (United States)

    Bouaud, J.

    2016-01-01

    Summary Objective To summarize recent research and select the best papers published in 2015 in the field of computerized clinical decision support for the Decision Support section of the IMIA yearbook. Method A literature review was performed by searching two bibliographic databases for papers related to clinical decision support systems (CDSSs) and computerized provider order entry (CPOE) systems. The aim was to identify a list of candidate best papers from the retrieved papers that were then peer-reviewed by external reviewers. A consensus meeting between the two section editors and the IMIA editorial team was finally conducted to conclude in the best paper selection. Results Among the 974 retrieved papers, the entire review process resulted in the selection of four best papers. One paper reports on a CDSS routinely applied in pediatrics for more than 10 years, relying on adaptations of the Arden Syntax. Another paper assessed the acceptability and feasibility of an important CPOE evaluation tool in hospitals outside the US where it was developed. The third paper is a systematic, qualitative review, concerning usability flaws of medication-related alerting functions, providing an important evidence-based, methodological contribution in the domain of CDSS design and development in general. Lastly, the fourth paper describes a study quantifying the effect of a complex, continuous-care, guideline-based CDSS on the correctness and completeness of clinicians’ decisions. Conclusions While there are notable examples of routinely used decision support systems, this 2015 review on CDSSs and CPOE systems still shows that, despite methodological contributions, theoretical frameworks, and prototype developments, these technologies are not yet widely spread (at least with their full functionalities) in routine clinical practice. Further research, testing, evaluation, and training are still needed for these tools to be adopted in clinical practice and, ultimately, illustrate

  8. Towards Vision-Based Control of a Handheld Micromanipulator for Retinal Cannulation in an Eyeball Phantom

    Science.gov (United States)

    Becker, Brian C.; Yang, Sungwook; MacLachlan, Robert A.; Riviere, Cameron N.

    2012-01-01

    Injecting clot-busting drugs such as t-PA into tiny vessels thinner than a human hair in the eye is a challenging procedure, especially since the vessels lie directly on top of the delicate and easily damaged retina. Various robotic aids have been proposed with the goal of increasing safety by removing tremor and increasing precision with motion scaling. We have developed a fully handheld micromanipulator, Micron, that has demonstrated reduced tremor when cannulating porcine retinal veins in an “open sky” scenario. In this paper, we present work towards handheld robotic cannulation with the goal of vision-based virtual fixtures guiding the tip of the cannula to the vessel. Using a realistic eyeball phantom, we address sclerotomy constraints, eye movement, and non-planar retina. Preliminary results indicate a handheld micromanipulator aided by visual control is a promising solution to retinal vessel occlusion. PMID:24649479

  9. Building the Vocational Phase of the Computerized Motor Skills Testing System for Use in the Electronics and Electrical Engineering Group and Hospitality Group

    Science.gov (United States)

    Hsiao, Hsien-Sheng; Chen, Jyun-Chen; Hong, Kunde

    2016-01-01

    Technical and vocational education emphasizes the development and training of hand motor skills. However, some problems exist in the current career and aptitude tests in that they do not truly measure the hand motor skills. This study used the Nintendo Wii Remote Controller as the testing device in developing a set of computerized testing tools to…

  10. Driver hand-held cellular phone use: a four-year analysis.

    Science.gov (United States)

    Eby, David W; Vivoda, Jonathon M; St Louis, Renée M

    2006-01-01

    The use of hand-held cellular (mobile) phones while driving has stirred more debate, passion, and research than perhaps any other traffic safety issue in the past several years. There is ample research showing that the use of either hand-held or hands-free cellular phones can lead to unsafe driving patterns. Whether or not these performance deficits increase the risk of crash is difficult to establish, but recent studies are beginning to suggest that cellular phone use elevates crash risk. The purpose of this study was to assess changes in the rate of hand-held cellular phone use by motor-vehicle drivers on a statewide level in Michigan. This study presents the results of 13 statewide surveys of cellular phone use over a 4-year period. Hand-held cellular phone use data were collected through direct observation while vehicles were stopped at intersections and freeway exit ramps. Data were weighted to be representative of all drivers traveling during daylight hours in Michigan. The study found that driver hand-held cellular phone use has more than doubled between 2001 and 2005, from 2.7% to 5.8%. This change represents an average increase of 0.78 percentage points per year. The 5.8% use rate observed in 2005 means that at any given daylight hour, around 36,550 drivers were conversing on cellular phones while driving on Michigan roadways. The trend line fitted to these data predicts that by the year 2010, driver hand-held cellular phone use will be around 8.6%, or 55,000 drivers at any given daylight hour. These results make it clear that cellular phone use while driving will continue to be an important traffic safety issue, and highlight the importance of continued attempts to generate new ways of alleviating this potential hazard.

  11. Standardization from a benchtop to a handheld NIR spectrometer using mathematically mixed NIR spectra to determine fuel quality parameters

    DEFF Research Database (Denmark)

    da Silva, Neirivaldo Cavalcante; Cavalcanti, Claudia Jessica; Honorato, Fernanda Araujo

    2017-01-01

    spectral responses of fuel samples (gasoline and biodiesel blends) from a high-resolution benchtop Frontier FT-NIR (PerkinElmer) spectrometer and a handheld MicroNIR™1700 (JDSU). These virtual standards can be created by mathematically mixing spectra from the pure solvents present in gasoline or diesel...... to the handheld MicroNIR using virtual standards as transfer samples...

  12. Validity of maximal isometric knee extension strength measurements obtained via belt-stabilized hand-held dynamometry in healthy adults.

    Science.gov (United States)

    Ushiyama, Naoko; Kurobe, Yasushi; Momose, Kimito

    2017-11-01

    [Purpose] To determine the validity of knee extension muscle strength measurements using belt-stabilized hand-held dynamometry with and without body stabilization compared with the gold standard isokinetic dynamometry in healthy adults. [Subjects and Methods] Twenty-nine healthy adults (mean age, 21.3 years) were included. Study parameters involved right side measurements of maximal isometric knee extension strength obtained using belt-stabilized hand-held dynamometry with and without body stabilization and the gold standard. Measurements were performed in all subjects. [Results] A moderate correlation and fixed bias were found between measurements obtained using belt-stabilized hand-held dynamometry with body stabilization and the gold standard. No significant correlation and proportional bias were found between measurements obtained using belt-stabilized hand-held dynamometry without body stabilization and the gold standard. The strength identified using belt-stabilized hand-held dynamometry with body stabilization may not be commensurate with the maximum strength individuals can generate; however, it reflects such strength. In contrast, the strength identified using belt-stabilized hand-held dynamometry without body stabilization does not reflect the maximum strength. Therefore, a chair should be used to stabilize the body when performing measurements of maximal isometric knee extension strength using belt-stabilized hand-held dynamometry in healthy adults. [Conclusion] Belt-stabilized hand-held dynamometry with body stabilization is more convenient than the gold standard in clinical settings.

  13. Diagnostics of neuromuscular diseases with the aid of computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Visser, M de; Verbeeten, Jr, B J

    1988-06-04

    In this article the diagnosis of neuromuscular diseases with the aid of computerized tomography is treated. Computerized tomography of skeletal muscles give no information which is pathognomonic for particular diseases. But the technique can be used in the following aspects: to choose a muscle for a biopsy; when it is not possible to examine the function of a muscle, a CT scan can visualize morphological deviations; in the differentiation of muscle hypertrophy and pseudo-hypertrophy. For some cases as Becker-type muscular dystrophy, facioscapulohumeral dystrophy and Kugelberg-Welander type spinal muscular atrophy computerized tomography gives characteristic images. 10 refs.; 6 figs.

  14. Diagnostics of neuromuscular diseases with the aid of computerized tomography

    International Nuclear Information System (INIS)

    Visser, M. de; Verbeeten, B.J. Jr.

    1988-01-01

    In this article the diagnosis of neuromuscular diseases with the aid of computerized tomography is treated. Computerized tomography of skeletal muscles give no information which is pathognomonic for particular diseases. But the technique can be used in the following aspects: to choose a muscle for a biopsy; when it is not possible to examine the function of a muscle, a CT scan can visualize morphological deviations; in the differentiation of muscle hypertrophy and pseudo-hypertrophy. For some cases as Becker-type muscular dystrophy, facioscapulohumeral dystrophy and Kugelberg-Welander type spinal muscular atrophy computerized tomography gives characteristic images. 10 refs.; 6 figs

  15. Results of CT brain examinations in cerebrovascular emergency. [computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Pinta, Z; Dolansky, J; Sorfova, J; Jerie, T

    1987-07-01

    Experience is briefly reported with CT (computerized tomography) diagnosis of cerebrovascular emergencies. It is pointed out that the introduction of computerized tomography greatly improved and made more accurate the diagnosis of focal ischemias and revealed significant differences in the foci of ischemia in hypertension patients and atherosclerosis patients without hypertension, and showed a higher incidence of intracerebral and subarachnoidal hemorrhages than previously thought. It is believed that knowledge gained thanks to CT (computerized tomography) will be of benefit to the primary and secondary prevention of cerebrovascular ischemias. (L.O.). 1 fig., 5 refs.

  16. Research on accounting transition from computerization to informationization

    Directory of Open Access Journals (Sweden)

    Shu Chen

    2017-11-01

    Full Text Available The application for computer technology, digitalization technology and network technology in the accounting field has promoted the development of accounting informationization. Accounting informationization is a product integrated with traditional accounting theory and modern information technology, which is an inevitable trend of continuous development of modern accounting. This paper discusses the basic concepts and characteristics of accounting computerization and informationization based on the normative research method and literature data method, analyzes the feasibility of accounting transition from computerization to informationization, and finally puts forward the specific approaches and ultimate goals of accounting transition from computerization to informationization.

  17. Three-dimensional computerized mobilization of the cervical spine for the treatment of chronic neck pain: a pilot study.

    Science.gov (United States)

    River, Yaron; Aharony, Shelly; Bracha, Jillian; Levital, Tamir; Gerwin, Robert

    2014-07-01

    Manual therapies for chronic neck pain are imprecise, inconsistent, and brief due to therapist fatigue. A previous study showed that computerized mobilization of the cervical spine in the sagittal plane is a safe and potentially effective treatment of chronic neck pain. To investigate the safety and efficacy of computerized mobilization of the cervical spine in a three-dimensional space for the treatment of chronic neck pain. Pilot, open trial. Physical therapy outpatient department. Nine patients with chronic neck pain. A computerized cradle capable of three-dimensional neck mobilizations was used. Treatment sessions lasted 20 minutes, biweekly, for six weeks. Visual analog scale (VAS) for pain, cervical range of motion (CROM), neck disability index (NDI), joint position error (JPE), and muscle algometry. Comparing baseline at week one with week six (end of treatment), the VAS scores dropped by 2.9 points (P pain threshold in any muscle tested. There were no significant adverse effects. These preliminary results demonstrate that this novel, computerized, three-dimensional cervical mobilization device is probably safe. The data also suggest that this method is effective in alleviating neck pain and associated headache, and in increasing the CROM, although the sample size was small in this open trial. Wiley Periodicals, Inc.

  18. Accessible virtual reality therapy using portable media devices.

    Science.gov (United States)

    Bruck, Susan; Watters, Paul A

    2010-01-01

    Simulated immersive environments displayed on large screens are a valuable therapeutic asset in the treatment of a range of psychological disorders. Permanent environments are expensive to build and maintain, require specialized clinician training and technical support and often have limited accessibility for clients. Ideally, virtual reality exposure therapy (VRET) could be accessible to the broader community if we could use inexpensive hardware with specifically designed software. This study tested whether watching a handheld non-immersive media device causes nausea and other cybersickness responses. Using a repeated measure design we found that nausea, general discomfort, eyestrain, blurred vision and an increase in salivation significantly increased in response to handheld non-immersive media device exposure.

  19. Enabling GPU-assisted Antivirus Protection on Android Devices Through Edge Offloading

    DEFF Research Database (Denmark)

    Deyannis, Dimitris; Tsirbas, Rafail; Vasiliadis, Giorgos

    2018-01-01

    Antivirus software are the most popular tools for detecting and stopping malicious or unwanted files. However, the performance requirements of traditional host-based antivirus make their wide adoption to mobile, embedded, and hand-held devices questionable. Their computational- and memory...

  20. Hand-held Raman sensor head for in-situ characterization of meat quality applying a microsystem 671 nm diode laser

    Science.gov (United States)

    Schmidt, Heinar; Sowoidnich, Kay; Maiwald, Martin; Sumpf, Bernd; Kronfeldt, Heinz-Detlef

    2009-05-01

    A hand-held Raman sensor head was developed for the in-situ characterization of meat quality. As light source, a microsystem based external cavity diode laser module (ECDL) emitting at 671 nm was integrated in the sensor head and attached to a miniaturized optical bench which contains lens optics for excitation and signal collection as well as a Raman filter stage for Rayleigh rejection. The signal is transported with an optical fiber to the detection unit which was in the initial phase a laboratory spectrometer with CCD detector. All elements of the ECDL are aligned on a micro optical bench with 13 x 4 mm2 footprint. The wavelength stability is provided by a reflection Bragg grating and the laser has an optical power of up to 200 mW. However, for the Raman measurements of meat only 35 mW are needed to obtain Raman spectra within 1 - 5 seconds. Short measuring times are essential for the hand-held device. The laser and the sensor head are characterized in terms of stability and performance for in-situ Raman investigations. The function is demonstrated in a series of measurements with raw and packaged pork meat as samples. The suitability of the Raman sensor head for the quality control of meat and other products will be discussed.

  1. Computerized data base of the fundamental constants of nature

    International Nuclear Information System (INIS)

    Henry, E.A.; Hampel, V.E.

    1975-01-01

    Fifty-seven fundamental constants of nature were computerized from the up-to-date evaluations of E. R. Cohen and B. N. Taylor. The constants are annotated with regard to symbol, value, uncertainty, and scaling factor. This computerization is part of the scientific data base project of the Information Research Group at Lawrence Livermore Laboratory. The MASTER CONTROL data base management system is used. The computerized fundamental constants can be requested from the ERDA Computer Program Exchange and Information Center of the Argonne National Laboratory or from the National Technical Information Service of the U. S. Department of Commerce. This is the first of a series of releases on preparation of computerized scientific and technological data banks. The next release is a data bank of conversion factors for different units of measurements. 3 figures

  2. Cranial computerized tomography in children suffering from acute leukemia

    International Nuclear Information System (INIS)

    Metz, O.

    1981-01-01

    Cranial computerized (axial) tomography permits a more complete neurologic supervision of children with acute leukemia and a better knowledge of the frequency and varieties of cerebral complications in leukemia. Endocranial complications in acute leukemia are essentially infiltrative, hemorrhagic, infectious or iatrogenic. Cranial computerized tomography can demonstrate cerebral changes in meningeal leukemia, hemorrhages, calcifications, brain atrophy or leukencephalopathy. The preliminary results of cranial computerized tomography in childhood leukemia suggest that the iatrogenic main lesion of the brain due to combined radiation-chemotherapy is atrophy whereas that of the intrathecal cytostatic therapy is demyelination. Accurate diagnostics and control of possible cerebral complications in therapy of leukemia is essentially for appropriate therapeutic management. For that cranial computerized tomography is the best method to a effective supervision of the brain. (author)

  3. Computerized Point of Sale = Faster Service + Better Accountability.

    Science.gov (United States)

    Pannell, Dorothy V.

    1991-01-01

    Describes selecting and installing a computerized point of sale for a district food service program; the equipment needed and preferred; and the training of trainers, managers, and cashiers. Also discusses the direct benefits and side benefits of the system. (MLF)

  4. 381 Developing of a Computerized Brain Diagnosing System for ...

    African Journals Online (AJOL)

    User

    Ogunsanwo O. D. - Department of Computer Science, Gate way ICT ... computerized brain diagnosing system that would be used in carrying out the ..... This aspect explores the techniques use for the design of interface, menus and databases ...

  5. Computerized Tomography and its Applications : a Guided Tour

    NARCIS (Netherlands)

    Roerdink, J.B.T.M.

    1992-01-01

    We present a review of the mathematical principles of computerized tomography. Topics treated include the role of the Radon transform and related transforms, inversion formulas, uniqueness, ill-posedness and stability, practical reconstruction algorithms, and various generalizations such as

  6. Algorithmic fundamentals of computerized tomography and of transverse analogue tomography

    International Nuclear Information System (INIS)

    Heckmann, K.

    1981-01-01

    Computerized tomography and transverse analogue tomography are two different approaches to the same goal, namely, transverse tomography. The algorithm is discussed and compared. Transverse tomography appears capable of further development, judging by this comparison. (orig.) [de

  7. Survey of methods for improving operator acceptance of computerized aids

    International Nuclear Information System (INIS)

    Frey, P.R.; Kisner, R.A.

    1982-04-01

    The success of current attempts to improve the operational performance and safety of nuclear power plants by installing computerized operational aids in the control rooms is dependent, in part, on the operator's attitude toward the aid. Utility experience with process computer systems indicates that problems may already exist with operator acceptance of computerized aids. The growth of the role that computers have in nuclear power plants makes user acceptance of computer technology an important issue for the nuclear industry. The purpose of this report is to draw from the literature factors related to user acceptance of computerized equipment that may also be applicable to the acceptance of computerized aids used in the nuclear power plant control room

  8. Development of a computerized handbook of architectural plans

    NARCIS (Netherlands)

    Koutamanis, A.

    1990-01-01

    The dissertation investigates an approach to the development of visual / spatial computer representations for architectural purposes through the development of the computerized handbook of architectural plans (chap), a knowledge-based computer system capable of recognizing the metric properties of

  9. Survey of methods for improving operator acceptance of computerized aids

    Energy Technology Data Exchange (ETDEWEB)

    Frey, P. R.; Kisner, R. A.

    1982-04-01

    The success of current attempts to improve the operational performance and safety of nuclear power plants by installing computerized operational aids in the control rooms is dependent, in part, on the operator's attitude toward the aid. Utility experience with process computer systems indicates that problems may already exist with operator acceptance of computerized aids. The growth of the role that computers have in nuclear power plants makes user acceptance of computer technology an important issue for the nuclear industry. The purpose of this report is to draw from the literature factors related to user acceptance of computerized equipment that may also be applicable to the acceptance of computerized aids used in the nuclear power plant control room.

  10. Computerized tomographic evaluation of aortic prosthetic graft complications

    International Nuclear Information System (INIS)

    Kay, D.; Kalmar, J.A.

    1985-01-01

    Computerized tomography has been found to be an accurate and sensitive method of diagnosing complications of synthetic aortic grafts. Complications in this series of four cases included aortoesophageal fistula, aortoduodenal fistula, pseudoaneurysm, and retroperitoneal hematoma. 6 references, 5 figures

  11. Computerized Analysis and Detection of Missed Cancer in Screening Mammogram

    National Research Council Canada - National Science Library

    Li, Lihua

    2005-01-01

    This project is to explore an innovative CAD strategy for improving early detection of breast cancer in screening mammograms by focusing on computerized analysis and detection of cancers missed by radiologists...

  12. Computerized Analysis and Detection of Missed Cancer in Screening Mammogram

    National Research Council Canada - National Science Library

    Li, Lihua

    2004-01-01

    This project is to explore an innovative CAD strategy for improving early detection of breast cancer in screening mammograms by focusing on computerized analysis and detection of cancers missed by radiologists...

  13. Journal of EEA, Vol. 30, 2013 COMPUTERIZED FACILITIES ...

    African Journals Online (AJOL)

    dell

    Key words: Computer Aided Layout Design,. Construction ... Commonly used software are ... popular improvement-type methods are. Computerized Relative Allocation of Facilities .... closeness ratings values are given different numerical.

  14. Audiovisual Presentations on a Handheld PC are Preferred As an Educational Tool by NICU Parents.

    Science.gov (United States)

    Alur, P; Cirelli, J; Goodstein, M; Bell, T; Liss, J

    2010-01-01

    Health literacy is critical for understanding complex medical problems and necessary for the well being of the patient. Printed educational materials (PM) have limitations in explaining the dynamics of a disease process. Multimedia formats may be useful for enhancing the educational process. To evaluate whether a printed format or animation with commentary on a handheld personal computer (PC) is preferred as an educational tool by parents of a baby in the NICU. PARENTS EVALUATED TWO FORMATS: A 1-page illustrated document from the American Heart Association explaining patent ductus arteriosus (PDA) and animation with commentary on a handheld PC that explained the physiology of PDA in 1 minute. The reading grade level of the PM was 8.6 versus 18.6 for the audio portion of the animated presentation. Parents viewed each format and completed a four-item questionnaire. Parents rated both formats and indicated their preference as printed, animation, or both. Forty-six parents participated in the survey. Parents preferred animation over PM (50% vs. 17.4%. p = 0.02); 39.1% expressed that the animation was excellent; whereas 4.3% expressed that the PM was excellent (p0.05). Parents preferred animation on a small screen handheld PC despite a much higher language level. Because handheld PCs are portable and inexpensive, they can be used effectively at the bedside with low-cost animation to enhance understanding of complex disease conditions.

  15. How to use hand-held computers to evaluate wood drying.

    Science.gov (United States)

    Howard N. Rosen; Darrell S. Martin

    1985-01-01

    Techniques have been developed to evaluate end generate wood drying curves with hand-held computers (3-5K memory). Predictions of time to dry to a specific moisture content, drying rates, and other characteristics of wood drying curves can be made. The paper describes the development of programs and illustrates their use.

  16. Epidemiology of Handheld Cell Phone Use While Driving: A Study from a South Indian City

    Directory of Open Access Journals (Sweden)

    Sumanth Mallikarjuna Majgi

    2018-01-01

    Full Text Available Background: Using cell phones while driving contribute to distractions which can potentially cause minor or major road traffic injuries and also stress among other drivers. With this background, the study was done to ascertain the proportion of handheld cell phone use while driving among road users in Mysore city and also patterns of the use by the day of week, type of road, and type of vehicle. Methods: The study was conducted in Mysore, Karnataka, India. Four stretches of roads were observed thrice daily for 1 week. The total number of vehicles passing through the stretch and the number and characteristics of drivers using hand-held cell was noted. Pearson's Chi-square test was used to ascertain the significance of the difference in proportions. Results: The overall proportion of cell phone users was calculated as 1.41/100 vehicles. The observed use of handheld cell phones was 1.78 times higher on nonbusy roads than busy roads (Χ2 = 25.79, P < 0.0001. More than 50% of the handheld phone users were driving a two wheeler, the proportion being 50.5% in busy roads, and 67% in nonbusy roads. There was no difference in the proportion of cell phone use by time of the day or across different days of the week. Conclusions: The proportion of drivers who use cell phones is found to be relatively lower, and use of cell phones was higher on nonbusy roads.

  17. A Fresh Look at the Crystal Violet Lab with Handheld Camera Colorimetry

    Science.gov (United States)

    Knutson, Theodore R.; Knutson, Cassandra M.; Mozzetti, Abbie R.; Campos, Antonio R.; Haynes, Christy L.; Penn, R. Lee

    2015-01-01

    Chemical kinetic experiments to determine rate laws are common in high school and college chemistry courses. For reactions involving a color change, rate laws can be determined experimentally using spectrophotometric or colorimetric equipment though this equipment can be cost prohibitive. Previous work demonstrated that inexpensive handheld camera…

  18. The Xsense project: The application of an intelligent sensor array for high sensitivity handheld explosives detectors

    DEFF Research Database (Denmark)

    Kostesha, Natalie; Schmidt, Michael Stenbæk; Bosco, Filippo

    2011-01-01

    Multiple independent sensors are used in security and military applications in order to increase sensitivity, selectivity and data reliability. The Xsense project has been initiated at the Technical University of Denmark in collaboration with a number of partners in an effort to produce a handheld...

  19. Survey reveals public open to ban on hand-held cell phone use and texting.

    Science.gov (United States)

    2013-01-01

    A study performed by the Bureau of Transportation Statistics (BTS) reveals that the public is open to a ban on hand-held cell phone use while driving. The study is based on data from 2009s Omnibus Household Survey (OHS), which is administered by B...

  20. Applying Hand-Held 3D Printing Technology to the Teaching of VSEPR Theory

    Science.gov (United States)

    Dean, Natalie L.; Ewan, Corrina; McIndoe, J. Scott

    2016-01-01

    The use of hand-held 3D printing technology provides a unique and engaging approach to learning VSEPR theory by enabling students to draw three-dimensional depictions of different molecular geometries, giving them an appreciation of the shapes of the building blocks of complex molecular structures. Students are provided with 3D printing pens and…

  1. Xsense: using nanotechnology to combine detection methods for high sensitivity handheld explosives detectors

    DEFF Research Database (Denmark)

    Schmidt, Michael Stenbæk; Kostesha, Natalie; Bosco, Filippo

    2010-01-01

    In an effort to produce a handheld explosives sensor the Xsense project has been initiated at the Technical University of Denmark in collaboration with a number of partners. Using micro- and nano technological approaches it will be attempted to integrate four detection principles into a single de...

  2. Radiation safety evaluation of a hand-held, battery operated image intensifier

    International Nuclear Information System (INIS)

    Wilson, O.J.; Young, B.F.

    1987-01-01

    A portable, hand-held, fluoroscopic unit intended for medical and industrial use was tested to verify the claim of the manufacturers that the radiation doses to the patient and user are low, and comparable to those received from standard radiographic procedures. The first claim was substantiated but not the second. A number of concerns arising from the use of this unit are discussed

  3. Clinical translation of handheld optical coherence tomography: practical considerations and recent advancements

    Science.gov (United States)

    Monroy, Guillermo L.; Won, Jungeun; Spillman, Darold R.; Dsouza, Roshan; Boppart, Stephen A.

    2017-12-01

    Since the inception of optical coherence tomography (OCT), advancements in imaging system design and handheld probes have allowed for numerous advancements in disease diagnostics and characterization of the structural and optical properties of tissue. OCT system developers continue to reduce form factor and cost, while improving imaging performance (speed, resolution, etc.) and flexibility for applicability in a broad range of fields, and nearly every clinical specialty. An extensive array of components to construct customized systems has also become available, with a range of commercial entities that produce high-quality products, from single components to full systems, for clinical and research use. Many advancements in the development of these miniaturized and portable systems can be linked back to a specific challenge in academic research, or a clinical need in medicine or surgery. Handheld OCT systems are discussed and explored for various applications. Handheld systems are discussed in terms of their relative level of portability and form factor, with mention of the supporting technologies and surrounding ecosystem that bolstered their development. Additional insight from our efforts to implement systems in several clinical environments is provided. The trend toward well-designed, efficient, and compact handheld systems paves the way for more widespread adoption of OCT into point-of-care or point-of-procedure applications in both clinical and commercial settings.

  4. Acute pain management efficiency improves with point-of-care handheld electronic billing system.

    Science.gov (United States)

    Fahy, Brenda G

    2009-02-01

    Technology advances continue to impact patient care and physician workflow. To enable more efficient performance of billing activities, a point-of-care (POC) handheld computer technology replaced a paper-based system on an acute pain management service. Using a handheld personal digital assistant (PDA) and software from MDeverywhere (MDe, MDeverywhere, Long Island, NY), we performed a 1-yr prospective observational study of an anesthesiology acute pain management service billings and collections. Seventeen anesthesiologists providing billable acute pain services were trained and entered their charges on a PDA. Twelve months of data, just before electronic implementation (pre-elec), were compared to a 12-m period after implementation (post-elec). The total charges were 4883 for 890 patients pre-elec and 5368 for 1128 patients post-elec. With adoption of handheld billing, the charge lag days decreased from 29.3 to 7.0 (P billing using PDAs to replace a paper-based billing system improved the collection rate and decreased the number of charge lag days with a positive return on investment. The handheld PDA billing system provided POC support for physicians during their daily clinical (e.g., patient locations, rounding lists) and billing activities, improving workflow.

  5. A Mobile Mixed-Reality Environment for Children's Storytelling Using a Handheld Projector and a Robot

    Science.gov (United States)

    Sugimoto, Masanori

    2011-01-01

    This paper describes a system called GENTORO that uses a robot and a handheld projector for supporting children's storytelling activities. GENTORO differs from many existing systems in that children can make a robot play their own story in a physical space augmented by mixed-reality technologies. Pilot studies have been conducted to clarify the…

  6. A Study of the Use of a Handheld Computer Algebra System in Discrete Mathematics

    Science.gov (United States)

    Powers, Robert A.; Allison, Dean E.; Grassl, Richard M.

    2005-01-01

    This study investigated the impact of the TI-92 handheld Computer Algebra System (CAS) on student achievement in a discrete mathematics course. Specifically, the researchers examined the differences between a CAS section and a control section of discrete mathematics on students' in-class examinations. Additionally, they analysed student approaches…

  7. Efficacy of Handheld Electronic Visual Supports to Enhance Vocabulary in Children with ASD

    Science.gov (United States)

    Ganz, Jennifer B.; Boles, Margot B.; Goodwyn, Fara D.; Flores, Margaret M.

    2014-01-01

    Although electronic tools such as handheld computers have become increasingly common throughout society, implementation of such tools to improve skills in individuals with intellectual and developmental disabilities has lagged in the professional literature. However, the use of visual scripts for individuals with disabilities, particularly those…

  8. The Weak Link HP-41C hand-held calculator program

    Science.gov (United States)

    Ross A. Phillips; Penn A. Peters; Gary D. Falk

    1982-01-01

    The Weak Link hand-held calculator program (HP-41C) quickly analyzes a system for logging production and costs. The production equations model conventional chain saw, skidder, loader, and tandemaxle truck operations in eastern mountain areas. Production of each function of the logging system may be determined so that the system may be balanced for minimum cost. The...

  9. Stratification of mammographic computerized analysis by BI-RADS categories

    Energy Technology Data Exchange (ETDEWEB)

    Lederman, Richard [Department of Radiology, Hadassah University Hospital, Ein Kerem, Jerusalem (Israel); Leichter, Isaac [Department of Electro-Optics, Jerusalem College of Technology, P.O.B. 16031, Jerusalem (Israel); Buchbinder, Shalom [Department of Radiology of The Montefiore Medical Center, The University Hospital for the Albert Einstein College of Medicine, Bronx, New York (United States); Novak, Boris [Department of Applied Mathematics, Jerusalem College of Technology, P.O.B. 16031, Jerusalem 91160 (Israel); Bamberger, Philippe [Department of Electronics, Jerusalem College of Technology, POB 16031, Jerusalem (Israel); Fields, Scott [Department of Radiology, Hadassah University Hospital, Mt. Scopus, Jerusalem (Israel)

    2003-02-01

    The Breast Imaging Reporting and Data System (BI-RADS) was implemented to standardize characterization of mammographic findings. The purpose of the present study was to evaluate in which BI-RADS categories the changes recommended by computerized mammographic analysis are most beneficial. Archival cases including, 170 masses (101 malignant, 69 benign) and 63 clusters of microcalcifications (MCs; 36 malignant, 27 benign), were evaluated retrospectively, using the BI-RADS categories, by several radiologists, blinded to the pathology results. A computerized system then automatically extracted from the digitized mammogram features characterizing mammographic lesions, which were used to classify the lesions. The results of the computerized classification scheme were compared, by receiver operating characteristics (ROC) analysis, to the conventional interpretation. In the ''low probability of malignancy group'' (excluding BI-RADS categories 4 and 5), computerized analysis improved the A{sub z}of the ROC curve significantly, from 0.57 to 0.89. In the ''high probability of malignancy group'' (mostly category 5) the computerized analysis yielded an ROC curve with an A {sub z}of 0.99. In the ''intermediate probability of malignancy group'' computerized analysis improved the A {sub z}significantly, from 0.66 for to 0.83. Pair-wise analysis showed that in the latter group the modifications resulting from computerized analysis were correct in 83% of cases. Computerized analysis has the ability to improve the performance of the radiologists exactly in the BI-RADS categories with the greatest difficulties in arriving at a correct diagnosis. It increased the performance significantly in the problematic group of ''intermediate probability of malignancy'' and pinpointed all the cases with missed cancers in the ''low probability'' group. (orig.)

  10. Computerized systems of NPP operators support. (Psychological problems)

    International Nuclear Information System (INIS)

    Mashin, V.A.

    1995-01-01

    Operator psychological problems arising in the work with NPP operators support computerized systems (OSCS) are considered. The conclusion is made that the OSCS intellectual application will bring the operator into dangerous dependence on his computerized assistant. To avoid this danger it is necessary by creation of the OSCS to divide specially the tasks areas of the operator and OSCS in order to assure the active role of the operator in the NPP control

  11. Stratification of mammographic computerized analysis by BI-RADS categories

    International Nuclear Information System (INIS)

    Lederman, Richard; Leichter, Isaac; Buchbinder, Shalom; Novak, Boris; Bamberger, Philippe; Fields, Scott

    2003-01-01

    The Breast Imaging Reporting and Data System (BI-RADS) was implemented to standardize characterization of mammographic findings. The purpose of the present study was to evaluate in which BI-RADS categories the changes recommended by computerized mammographic analysis are most beneficial. Archival cases including, 170 masses (101 malignant, 69 benign) and 63 clusters of microcalcifications (MCs; 36 malignant, 27 benign), were evaluated retrospectively, using the BI-RADS categories, by several radiologists, blinded to the pathology results. A computerized system then automatically extracted from the digitized mammogram features characterizing mammographic lesions, which were used to classify the lesions. The results of the computerized classification scheme were compared, by receiver operating characteristics (ROC) analysis, to the conventional interpretation. In the ''low probability of malignancy group'' (excluding BI-RADS categories 4 and 5), computerized analysis improved the A z of the ROC curve significantly, from 0.57 to 0.89. In the ''high probability of malignancy group'' (mostly category 5) the computerized analysis yielded an ROC curve with an A z of 0.99. In the ''intermediate probability of malignancy group'' computerized analysis improved the A z significantly, from 0.66 for to 0.83. Pair-wise analysis showed that in the latter group the modifications resulting from computerized analysis were correct in 83% of cases. Computerized analysis has the ability to improve the performance of the radiologists exactly in the BI-RADS categories with the greatest difficulties in arriving at a correct diagnosis. It increased the performance significantly in the problematic group of ''intermediate probability of malignancy'' and pinpointed all the cases with missed cancers in the ''low probability'' group. (orig.)

  12. Computerized adaptive testing--ready for ambulatory monitoring?

    DEFF Research Database (Denmark)

    Rose, Matthias; Bjørner, Jakob; Fischer, Felix

    2012-01-01

    Computerized adaptive tests (CATs) have abundant theoretical advantages over established static instruments, which could improve ambulatory monitoring of patient-reported outcomes (PROs). However, an empirical demonstration of their practical benefits is warranted.......Computerized adaptive tests (CATs) have abundant theoretical advantages over established static instruments, which could improve ambulatory monitoring of patient-reported outcomes (PROs). However, an empirical demonstration of their practical benefits is warranted....

  13. The portable micro-computerized multichannel spectrometer for geological application

    International Nuclear Information System (INIS)

    Fang Fang; Jia Wenyi; Zou Rongsheng; Ma Yingjie; Zhou Jianbin

    1999-01-01

    The portable micro-computerized multichannel spectrometer is based on the book computer and employs the A/D integrated circuit with 12 bits. It is a 2048 channel spectrometer which is consisted of hardware and software. The author analyzed the hardware circuit and software construction of the micro-computerized multichannel spectrometer which is suitable for filed geological application. The main technical specifications and application of the new multichannel spectrometer were also discussed

  14. The portable micro-computerized multichannel spectrometer for geological application

    International Nuclear Information System (INIS)

    Fang Fang; Jia Wenyi; Zhou Rongsheng; Ma Yingjie; Zhou Jianbin

    1999-01-01

    The portable micro-computerized multichannel spectrometer is based on the book computer and employs the A/D integrated circuit with 12 bits. It is a 2048 channel spectrometer which consists of hardware and software. The author analyzed the hardware circuit and software construction of the micro-computerized multichannel spectrometer which is suitable for field geological application. The main technical specifications and application of the new multichannel spectrometer were also discussed

  15. Accuracy of Mobile Phone and Handheld Light Microscopy for the Diagnosis of Schistosomiasis and Intestinal Protozoa Infections in Côte d'Ivoire.

    Directory of Open Access Journals (Sweden)

    Jean T Coulibaly

    2016-06-01

    Full Text Available Handheld light microscopy using compact optics and mobile phones may improve the quality of health care in resource-constrained settings by enabling access to prompt and accurate diagnosis.Laboratory technicians were trained to operate two handheld diagnostic devices (Newton Nm1 microscope and a clip-on version of the mobile phone-based CellScope. The accuracy of these devices was compared to conventional light microscopy for the diagnosis of Schistosoma haematobium, S. mansoni, and intestinal protozoa infection in a community-based survey in rural Côte d'Ivoire. One slide of 10 ml filtered urine and a single Kato-Katz thick smear from 226 individuals were subjected to the Newton Nm1 microscope and CellScope for detection of Schistosoma eggs and compared to conventional microscopy. Additionally, 121 sodium acetate-acetic acid-formalin (SAF-fixed stool samples were examined by the Newton Nm1 microscope and compared to conventional microscopy for the diagnosis of intestinal protozoa.The prevalence of S. haematobium, S. mansoni, Giardia intestinalis, and Entamoeba histolytica/E. dispar, as determined by conventional microscopy, was 39.8%, 5.3%, 20.7%, and 4.9%, respectively. The Newton Nm1 microscope had diagnostic sensitivities for S. mansoni and S. haematobium infection of 91.7% (95% confidence interval (CI 59.8-99.6% and 81.1% (95% CI 71.2-88.3%, respectively, and specificities of 99.5% (95% CI 97.0-100% and 97.1% (95% CI 92.2-99.1%, respectively. The CellScope demonstrated sensitivities for S. mansoni and S. haematobium of 50.0% (95% CI 25.4-74.6% and 35.6% (95% CI 25.9-46.4%, respectively, and specificities of 99.5% (95% CI 97.0-100% and 100% (95% CI 86.7-100%, respectively. For G. intestinalis and E. histolytica/E. dispar, the Newton Nm1 microscope had sensitivity of 84.0% (95% CI 63.1-94.7% and 83.3% (95% CI 36.5-99.1%, respectively, and 100% specificity.Handheld diagnostic devices can be employed in community-based surveys in resource

  16. Accuracy of Mobile Phone and Handheld Light Microscopy for the Diagnosis of Schistosomiasis and Intestinal Protozoa Infections in Côte d'Ivoire.

    Science.gov (United States)

    Coulibaly, Jean T; Ouattara, Mamadou; D'Ambrosio, Michael V; Fletcher, Daniel A; Keiser, Jennifer; Utzinger, Jürg; N'Goran, Eliézer K; Andrews, Jason R; Bogoch, Isaac I

    2016-06-01

    Handheld light microscopy using compact optics and mobile phones may improve the quality of health care in resource-constrained settings by enabling access to prompt and accurate diagnosis. Laboratory technicians were trained to operate two handheld diagnostic devices (Newton Nm1 microscope and a clip-on version of the mobile phone-based CellScope). The accuracy of these devices was compared to conventional light microscopy for the diagnosis of Schistosoma haematobium, S. mansoni, and intestinal protozoa infection in a community-based survey in rural Côte d'Ivoire. One slide of 10 ml filtered urine and a single Kato-Katz thick smear from 226 individuals were subjected to the Newton Nm1 microscope and CellScope for detection of Schistosoma eggs and compared to conventional microscopy. Additionally, 121 sodium acetate-acetic acid-formalin (SAF)-fixed stool samples were examined by the Newton Nm1 microscope and compared to conventional microscopy for the diagnosis of intestinal protozoa. The prevalence of S. haematobium, S. mansoni, Giardia intestinalis, and Entamoeba histolytica/E. dispar, as determined by conventional microscopy, was 39.8%, 5.3%, 20.7%, and 4.9%, respectively. The Newton Nm1 microscope had diagnostic sensitivities for S. mansoni and S. haematobium infection of 91.7% (95% confidence interval (CI) 59.8-99.6%) and 81.1% (95% CI 71.2-88.3%), respectively, and specificities of 99.5% (95% CI 97.0-100%) and 97.1% (95% CI 92.2-99.1%), respectively. The CellScope demonstrated sensitivities for S. mansoni and S. haematobium of 50.0% (95% CI 25.4-74.6%) and 35.6% (95% CI 25.9-46.4%), respectively, and specificities of 99.5% (95% CI 97.0-100%) and 100% (95% CI 86.7-100%), respectively. For G. intestinalis and E. histolytica/E. dispar, the Newton Nm1 microscope had sensitivity of 84.0% (95% CI 63.1-94.7%) and 83.3% (95% CI 36.5-99.1%), respectively, and 100% specificity. Handheld diagnostic devices can be employed in community-based surveys in resource

  17. Computerized cost model for pressurized water reactors

    International Nuclear Information System (INIS)

    Meneely, T.K.; Tabata, Hiroaki; Labourey, P.

    1999-01-01

    A computerized cost model has been developed in order to allow utility users to improve their familiarity with pressurized water reactor overnight capital costs and the various factors which influence them. This model organizes its cost data in the standard format of the Energy Economic Data Base (EEDB), and encapsulates simplified relationships between physical plant design information and capital cost information in a computer code. Model calculations are initiated from a base case, which was established using traditional cost calculation techniques. The user enters a set of plant design parameters, selected to allow consideration of plant models throughout the typical three- and four-loop PWR power range, and for plant sites in Japan, Europe, and the United States. Calculation of the new capital cost is then performed in a very brief time. The presentation of the program's output allows comparison of various cases with each other or with separately calculated baseline data. The user can start at a high level summary, and by selecting values of interest on a display grid show progressively more and more detailed information, including links to background information such as individual cost driver accounts and physical plant variables for each case. Graphical presentation of the comparison summaries is provided, and the numerical results may be exported to a spreadsheet for further processing. (author)

  18. Language networks associated with computerized semantic indices.

    Science.gov (United States)

    Pakhomov, Serguei V S; Jones, David T; Knopman, David S

    2015-01-01

    Tests of generative semantic verbal fluency are widely used to study organization and representation of concepts in the human brain. Previous studies demonstrated that clustering and switching behavior during verbal fluency tasks is supported by multiple brain mechanisms associated with semantic memory and executive control. Previous work relied on manual assessments of semantic relatedness between words and grouping of words into semantic clusters. We investigated a computational linguistic approach to measuring the strength of semantic relatedness between words based on latent semantic analysis of word co-occurrences in a subset of a large online encyclopedia. We computed semantic clustering indices and compared them to brain network connectivity measures obtained with task-free fMRI in a sample consisting of healthy participants and those differentially affected by cognitive impairment. We found that semantic clustering indices were associated with brain network connectivity in distinct areas including fronto-temporal, fronto-parietal and fusiform gyrus regions. This study shows that computerized semantic indices complement traditional assessments of verbal fluency to provide a more complete account of the relationship between brain and verbal behavior involved organization and retrieval of lexical information from memory. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Quality criteria for abdominal computerized tomography

    International Nuclear Information System (INIS)

    Huebener, K.H.; Kurtz, B.; Metzger, H.O.F.

    1985-01-01

    Quality, not only in obdominal computerized tomography, is determined by the measurable technical parameters and, to an important extent, also bei individual factors, among which the diagnostic skill and experience of the examiner is one of the most decisive. These individual factors and the part they play with regard to the quality of CT-assisted diagnosis may well equal the technical parameters, as they significantly influence the course of examinations, resulting indications for contrast medium application, and the sensitivity of the diagnosis. The authors are convinced that especially for abdominal CT, standardized examination techniques inevitably would bring down the diagnostic quality. The technical parameters are of equal significance to achieving the diagnostic optimum, and to these parameters one has to count equipment characteristics as well as the data given by the examiner. Exposure time, spatial resolution and density differentiation are given by the equipment specifications but have to be adapted to and optimised to the clinical problems involved in every case. Another important task is that of routine imaging of given anatomic structures, for adequate evaluation of individual conditions. (orig./MG) [de

  20. Patient radiation exposure in computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Pavlov, V [Meditsinska Akademiya, Sofia (Bulgaria)

    1980-01-01

    Radiation exposure to patients undergoing axial computerized tomography as a tool of neurological X-ray diagnostics was studied. Doses thereby delivered were compared with those from routine head films at X-ray tube parameters 200 W, 70 kV, and 70 cm target-to-patient distance. Radiation exposures were analyzed with a view to improving shielding and procedural techniques. Comparisons were made using LiF TLD measurements with an Alderson phantom (standard for axial computer tomography). Skin and intracranial space doses were compared using two computers, Siretom I and Siretom 2000, for various positionings: frontal, fronto-lateral, temporal, temporo-occipital, and occipital. In addition, patient body doses with or without shielding and doses to subjects attending sick children or restless adults were examined. Achievable protection was estimated for lead shields of 0.5 mm lead equivalent. It was concluded that radiation doses delivered to neurologic patients undergoing axial computer tomography are smaller than those resulting from conventional X-ray examinations.

  1. Single photon emission computerized tomography (SPECT)

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    Tomography in nuclear medicine did not originate after the introduction of X-ray computerized tomography (CT). Even in the days of rectilinear scanner, tomography was attempted with multiple detector heads rotating around the patient, but the counts at each plane were never very high to obtain a satisfactory image. A high resolution focusing collimator can look at different depths but taking several slices in one projection was a time consuming process. Rectilinear scanners lose lot of counts in the collimator to look at one point, at on time, in one plane. It is true that attempts to do tomography with gamma camera really got a boost after the success of CT. By that time, algorithms for doing reconstruction of images also were highly refined and for advanced. Clinical application of SPECT has become widespread now, because of the development of suitable radiopharmaceuticals and improvement in instrumentation. The SPECT provides a direct measure of regional organ function and is performed with nuclides such as 123 I and 99 Tc m that emit a mono-image photon during their decay. SPECT is far less expensive than positron emission tomography

  2. Computerized 50 liter volume calibration system

    International Nuclear Information System (INIS)

    Proffitt, T.H.

    1990-01-01

    A system has been designed for the Savannah River Site that will be used to calibrate product shipping containers. For accountability purposes, it is necessary that these containers be calibrated to a very high precision. The Computerized 50 Liter Volume Calibration System (CVCS), which is based on the Ideal Gas Law (IGL), will use reference volumes with precision of no less ±0.03%, and helium to calibrate the containers to have a total error of no greater than ±0.10%. A statistical interpretation of the system has given a theoretical total calculated error of ±0.08%. Tests with the system will be performed once fabrication is complete to experimentally verify the calculated error. Since the total error was calculated using the worst case scenario, the actual error should be significantly less than the calculated value. The computer controlled, totally automated system is traceable to the National Institute of Standards and Technology. The design, calibration procedure, and statistical interpretation of the system will be discussed. 1 ref

  3. A Computerized Procedure linked to Virtual Equipment

    International Nuclear Information System (INIS)

    Jung, Yeon Sub; Song, Tae Young

    2011-01-01

    Digital, information, and communication technologies have change human's behavior. This is because human has limitation to memorize and process information. Human has to access other information and real time information for important decisions. Those technologies are playing important roles. Nuclear power plants cannot be exception. Many accidents in nuclear power plants result from absent or incorrect information. The information for nuclear personnel is context sensitive. They don't have enough time to verify the context sensitive information. Therefore they skip the information, as resulting in incident. Nuclear personnel are usually carrying static paper procedures during local task performance. The procedure guides them steps to follow. There is, however, no dynamic and context sensitive information in the paper. The effect of the work is evaluated once while getting permission of the work. Afterward they are not informed. The static paper is generally simplified, so that it does not show detail of equipment being manipulated. Particularly novice workers feel difficult to understand the procedure due to lack of detail. Pictures of equipment inserted in the procedure are not enough for comprehension. A computerized procedure linked with virtual equipment is one of the best solutions to increase the detail of procedure. Virtual equipment, however, has still limitation not to provide real time information, because the virtual equipment is not synchronized with real plants

  4. Single photon emission computerized tomography (SPECT)

    Energy Technology Data Exchange (ETDEWEB)

    Ganatra, R D

    1993-12-31

    Tomography in nuclear medicine did not originate after the introduction of X-ray computerized tomography (CT). Even in the days of rectilinear scanner, tomography was attempted with multiple detector heads rotating around the patient, but the counts at each plane were never very high to obtain a satisfactory image. A high resolution focusing collimator can look at different depths but taking several slices in one projection was a time consuming process. Rectilinear scanners lose lot of counts in the collimator to look at one point, at on time, in one plane. It is true that attempts to do tomography with gamma camera really got a boost after the success of CT. By that time, algorithms for doing reconstruction of images also were highly refined and for advanced. Clinical application of SPECT has become widespread now, because of the development of suitable radiopharmaceuticals and improvement in instrumentation. The SPECT provides a direct measure of regional organ function and is performed with nuclides such as {sup 123}I and {sup 99}Tc{sup m} that emit a mono-image photon during their decay. SPECT is far less expensive than positron emission tomography

  5. Study on forefoot by computerized tomography

    Energy Technology Data Exchange (ETDEWEB)

    Machida, Eiichi (Nihon Univ., Tokyo. School of Medicine)

    1983-10-01

    Computerized tomography (CT) was used to study coronary sections of the forefoot in both normal and abnormal human feet. CT images of the transverse arches at the metatarsal head, middle and base of the shaft were classified into five patterns. In the pattern most commonly found in normal feet, the second metatarsus appeared elevated above the other metatarsal bones at all points, and there was a gradual and even reduction in elevation from the second to the fifth metatarsal. In cases of hallux valgus, however, a variety of deformities were noted in the arc of the second to fifth metatarsals, particularly at the head. The rotation of the first metatarsus and shift of the sesamoids were measured from CT images at the head of the first metatarsus. In hallux valgus, both the rotation and the sesamoid shift appeared to have a wider angle than in the case of normal feet. In normal feet, the differences between the rotation of the first metatarsus and shift of the sesamoids were relatively small, whereas in hallux valgus there was a much greater degree of variation. Furthermore, while normal feet the variation in rotation of the first metatarsus and sesamoid shift both tended to be either great or small, in hallux valgus a large degree of sesamoid shift was sometimes found in combination with a small degree of rotation of the first metatarsus.

  6. Study on forefoot by computerized tomography

    International Nuclear Information System (INIS)

    Machida, Eiichi

    1983-01-01

    Computerized tomography (CT) was used to study coronary sections of the forefoot in both normal and abnormal human feet. CT images of the transverse arches at the metatarsal head, middle and base of the shaft were classified into five patterns. In the pattern most commonly found in normal feet, the second metatarsus appeared elevated above the other metatarsal bones at all points, and there was a gradual and even reduction in elevation from the second to the fifth metatarsal. In cases of hallux valgus, however, a variety of deformities were noted in the arc of the second to fifth metatarsals, particularly at the head. The rotation of the first metatarsus and shift of the sesamoids were measured from CT images at the head of the first metatarsus. In hallux valgus, both the rotation and the sesamoid shift appeared to have a wider angle than in the case of normal feet. In normal feet, the differences between the rotation of the first metatarsus and shift of the sesamoids were relatively small, whereas in hallux valgus there was a much greater degree of variation. Furthermore, while normal feet the variation in rotation of the first metatarsus and sesamoid shift both tended to be either great or small, in hallux valgus a large degree of sesamoid shift was sometimes found in combination with a small degree of rotatin of the first metatarsus. (author)

  7. Agreement Between an Automated Volume Breast Scanner and Handheld Ultrasound for Diagnostic Breast Examinations.

    Science.gov (United States)

    Barr, Richard G; DeVita, Robert; Destounis, Stamatia; Manzoni, Federica; De Silvestri, Annalisa; Tinelli, Carmine

    2017-10-01

    To compare the agreement and interobserver variability of diagnostic handheld ultrasound (US) and a single volume on an automated breast volume scanner (ABVS) and to determine whether there was a significant difference if the ABVS was used by a sonographer or mammographic technologist. Ninety patients scheduled for diagnostic US examinations were randomized to either handheld US or the ABVS first. The AVBS was randomized between a sonographer and a mammographic technologist performing the study. The studies were blinded, randomized, and read by 2 radiologists. The lesion with the highest Breast Imaging Reporting and Data System (BI-RADS) score was used in the analysis. Final diagnoses were made by core biopsy or follow-up for 2 years. Lesions included 9 malignant and 81 benign. The 90 patients had a mean age ± SD of 53.1 ± 16.3 years. The κ value for agreement between the ABVS and handheld US was 0.831 (95% confidence interval, 0.744-0.925), whereas the global agreement for a 7-point BI-RADS score was 0.488 (0.372-0.560). The agreement between the ABVS and handheld US was nearly the same when the ABVS was used by a mammographic technologist (κ = 0.858 [0.723-0.963]) or sonographer (κ = 0.803 [0.596-1.000]; P = .47). The areas under the receiver operating characteristic curves for characterization by the ABVS were 0.91 (0.84-0.96) for reader 1 and 0.91 (0.83-0.96) for reader 2; those for handheld US were 0.91 (0.84-0.96) for reader 1 and 0.83 (0.74-0.90) for reader 2, with no statistical difference. The agreement based on pathologic images was κ = 0.831 (0.718-0.944); for handheld US, κ = 0.795 (0.623-0.967); and for the AVBS, κ = 0.869 (0.725-1.000). Performing a single-view diagnostic ABVS examination has good agreement with a handheld diagnostic US workup. There is no difference if the ABVS is used by a sonographer or mammographic technologist. © 2017 by the American Institute of Ultrasound in Medicine.

  8. Handheld computers for self-administered sensitive data collection: A comparative study in Peru

    Directory of Open Access Journals (Sweden)

    Hughes James P

    2008-03-01

    Full Text Available Abstract Background Low-cost handheld computers (PDA potentially represent an efficient tool for collecting sensitive data in surveys. The goal of this study is to evaluate the quality of sexual behavior data collected with handheld computers in comparison with paper-based questionnaires. Methods A PDA-based program for data collection was developed using Open-Source tools. In two cross-sectional studies, we compared data concerning sexual behavior collected with paper forms to data collected with PDA-based forms in Ancon (Lima. Results The first study enrolled 200 participants (18–29 years. General agreement between data collected with paper format and handheld computers was 86%. Categorical variables agreement was between 70.5% and 98.5% (Kappa: 0.43–0.86 while numeric variables agreement was between 57.1% and 79.8% (Spearman: 0.76–0.95. Agreement and correlation were higher in those who had completed at least high school than those with less education. The second study enrolled 198 participants. Rates of responses to sensitive questions were similar between both kinds of questionnaires. However, the number of inconsistencies (p = 0.0001 and missing values (p = 0.001 were significantly higher in paper questionnaires. Conclusion This study showed the value of the use of handheld computers for collecting sensitive data, since a high level of agreement between paper and PDA responses was reached. In addition, a lower number of inconsistencies and missing values were found with the PDA-based system. This study has demonstrated that it is feasible to develop a low-cost application for handheld computers, and that PDAs are feasible alternatives for collecting field data in a developing country.

  9. The Effectiveness and Clinical Usability of a Handheld Information Appliance

    Directory of Open Access Journals (Sweden)

    Patricia A. Abbott

    2012-01-01

    Full Text Available Clinical environments are complex, stressful, and safety critical—heightening the demand for technological solutions that will help clinicians manage health information efficiently and safely. The industry has responded by creating numerous, increasingly compact and powerful health IT devices that fit in a pocket, hook to a belt, attach to eyeglasses, or wheel around on a cart. Untethering a provider from a physical “place” with compact, mobile technology while delivering the right information at the right time and at the right location are generally welcomed in clinical environments. These developments however, must be looked at ecumenically. The cognitive load of clinicians who are occupied with managing or operating several different devices during the process of a patient encounter is increased, and we know from decades of research that cognitive overload frequently leads to error. “Technology crowding,” enhanced by the plethora of mobile health IT, can actually become an additional millstone for busy clinicians. This study was designed to gain a deeper understanding of clinicians’ interactions with a mobile clinical computing appliance (Motion Computing C5 designed to consolidate numerous technological functions into an all-in-one device. Features of usability and comparisons to current methods of documentation and task performance were undertaken and results are described.

  10. Development of Real-Time Dual-Display Handheld and Bench-Top Hybrid-Mode SD-OCTs

    Directory of Open Access Journals (Sweden)

    Nam Hyun Cho

    2014-01-01

    Full Text Available Development of a dual-display handheld optical coherence tomography (OCT system for retina and optic-nerve-head diagnosis beyond the volunteer motion constraints is reported. The developed system is portable and easily movable, containing the compact portable OCT system that includes the handheld probe and computer. Eye posterior chambers were diagnosed using the handheld probe, and the probe could be fixed to the bench-top cradle depending on the volunteers’ physical condition. The images obtained using this handheld probe were displayed in real time on the computer monitor and on a small secondary built-in monitor; the displayed images were saved using the handheld probe’s built-in button. Large-scale signal-processing procedures such as k-domain linearization, fast Fourier transform (FFT, and log-scaling signal processing can be rapidly applied using graphics-processing-unit (GPU accelerated processing rather than central-processing-unit (CPU processing. The Labview-based system resolution is 1,024 × 512 pixels, and the frame rate is 56 frames/s, useful for real-time display. The 3D images of the posterior chambers including the retina, optic-nerve head, blood vessels, and optic nerve were composed using real-time displayed images with 500 × 500 × 500 pixel resolution. A handheld and bench-top hybrid mode with a dual-display handheld OCT was developed to overcome the drawbacks of the conventional method.

  11. Development of a miRNA surface-enhanced Raman scattering assay using benchtop and handheld Raman systems.

    Science.gov (United States)

    Schechinger, Monika; Marks, Haley; Locke, Andrea; Choudhury, Mahua; Cote, Gerard

    2018-01-01

    DNA-functionalized nanoparticles, when paired with surface-enhanced Raman spectroscopy (SERS), can rapidly detect microRNA. However, widespread use of this approach is hindered by drawbacks associated with large and expensive benchtop Raman microscopes. MicroRNA-17 (miRNA-17) has emerged as a potential epigenetic indicator of preeclampsia, a condition that occurs during pregnancy. Biomarker detection using an SERS point-of-care device could enable prompt diagnosis and prevention as early as the first trimester. Recently, strides have been made in developing portable Raman systems for field applications. An SERS assay for miRNA-17 was assessed and translated from traditional benchtop Raman microscopes to a handheld system. Three different photoactive molecules were compared as potential Raman reporter molecules: a chromophore, malachite green isothiocyanate (MGITC), a fluorophore, tetramethylrhodamine isothiocyanate, and a polarizable small molecule 5,5-dithio-bis-(2-nitrobenzoic acid) (DTNB). For the benchtop Raman microscope, the DTNB-labeled assay yielded the greatest sensitivity under 532-nm laser excitation, but the MGITC-labeled assay prevailed at 785 nm. Conversely, DTNB was preferable for the miniaturized 785-nm Raman system. This comparison showed significant SERS enhancement variation in response to 1-nM miRNA-17, implying that the sensitivity of the assay may be more heavily dependent on the excitation wavelength, instrumentation, and Raman reporter chosen than on the plasmonic coupling from DNA/miRNA-mediated nanoparticle assemblies. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  12. Validation of Ankle Strength Measurements by Means of a Hand-Held Dynamometer in Adult Healthy Subjects

    Directory of Open Access Journals (Sweden)

    Andrea Ancillao

    2017-01-01

    Full Text Available Uniaxial Hand-Held Dynamometer (HHD is a low-cost device widely adopted in clinical practice to measure muscle force. HHD measurements depend on operator’s ability and joint movements. The aim of the work is to validate the use of a commercial HHD in both dorsiflexion and plantarflexion ankle strength measurements quantifying the effects of HHD misplacements and unwanted foot’s movements on the measurements. We used an optoelectronic system and a multicomponent load cell to quantify the sources of error in the manual assessment of the ankle strength due to both the operator’s ability to hold still the HHD and the transversal components of the exerted force that are usually neglected in clinical routine. Results showed that foot’s movements and angular misplacements of HHD on sagittal and horizontal planes were relevant sources of inaccuracy on the strength assessment. Moreover, ankle dorsiflexion and plantarflexion force measurements presented an inaccuracy less than 2% and higher than 10%, respectively. In conclusion, the manual use of a uniaxial HHD is not recommended for the assessment of ankle plantarflexion strength; on the contrary, it can be allowed asking the operator to pay strong attention to the HHD positioning in ankle dorsiflexion strength measurements.

  13. Development of a low cost, GPS-based upgrade to a standard handheld gamma detector for mapping environmental radioactive contamination

    International Nuclear Information System (INIS)

    Paridaens, J.

    2006-01-01

    A low cost extension to a standard handheld radiation monitor was developed, allowing one to perform outdoor georeferenced gamma measurements. It consists of a commercial wireless Bluetooth[reg] GPS receiver, a commercial RS-232 to Bluetooth[reg] converter combined with a standard Bluetooth[reg] enabled pocket personal computer (PPC). The system is intended for use in difficult to access areas, typically for foot campaigns. As the operator walks, a straightforward homemade visual basic program alternately reads GPS position and gamma dose rate into the PPC, creating a data log. This allows a single operator on foot to map between 50 and 200 ha of environmental radiation per day in very rugged areas, depending on the accessibility of the terrain and the detail required. On a test field with known contamination, a spatial precision of about 5-10 m was obtainable. The device was also used to reveal complex contamination patterns in the flooding zones of a radioactively contaminated small river

  14. Development of a miRNA surface-enhanced Raman scattering assay using benchtop and handheld Raman systems

    Science.gov (United States)

    Schechinger, Monika; Marks, Haley; Locke, Andrea; Choudhury, Mahua; Cote, Gerard

    2018-01-01

    DNA-functionalized nanoparticles, when paired with surface-enhanced Raman spectroscopy (SERS), can rapidly detect microRNA. However, widespread use of this approach is hindered by drawbacks associated with large and expensive benchtop Raman microscopes. MicroRNA-17 (miRNA-17) has emerged as a potential epigenetic indicator of preeclampsia, a condition that occurs during pregnancy. Biomarker detection using an SERS point-of-care device could enable prompt diagnosis and prevention as early as the first trimester. Recently, strides have been made in developing portable Raman systems for field applications. An SERS assay for miRNA-17 was assessed and translated from traditional benchtop Raman microscopes to a handheld system. Three different photoactive molecules were compared as potential Raman reporter molecules: a chromophore, malachite green isothiocyanate (MGITC), a fluorophore, tetramethylrhodamine isothiocyanate, and a polarizable small molecule 5,5-dithio-bis-(2-nitrobenzoic acid) (DTNB). For the benchtop Raman microscope, the DTNB-labeled assay yielded the greatest sensitivity under 532-nm laser excitation, but the MGITC-labeled assay prevailed at 785 nm. Conversely, DTNB was preferable for the miniaturized 785-nm Raman system. This comparison showed significant SERS enhancement variation in response to 1-nM miRNA-17, implying that the sensitivity of the assay may be more heavily dependent on the excitation wavelength, instrumentation, and Raman reporter chosen than on the plasmonic coupling from DNA/miRNA-mediated nanoparticle assemblies.

  15. Development of a low cost, GPS-based upgrade to a standard handheld gamma detector for mapping environmental radioactive contamination

    Energy Technology Data Exchange (ETDEWEB)

    Paridaens, J. [Belgian Nuclear Research Centre, SCK.CEN, Boeretang 200, B2400 Mol (Belgium)]. E-mail: jparidae@sckcen.be

    2006-02-15

    A low cost extension to a standard handheld radiation monitor was developed, allowing one to perform outdoor georeferenced gamma measurements. It consists of a commercial wireless Bluetooth[reg] GPS receiver, a commercial RS-232 to Bluetooth[reg] converter combined with a standard Bluetooth[reg] enabled pocket personal computer (PPC). The system is intended for use in difficult to access areas, typically for foot campaigns. As the operator walks, a straightforward homemade visual basic program alternately reads GPS position and gamma dose rate into the PPC, creating a data log. This allows a single operator on foot to map between 50 and 200 ha of environmental radiation per day in very rugged areas, depending on the accessibility of the terrain and the detail required. On a test field with known contamination, a spatial precision of about 5-10 m was obtainable. The device was also used to reveal complex contamination patterns in the flooding zones of a radioactively contaminated small river.

  16. Computerized tomographic evaluation of primary brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Ok; Lee, Jong Soon; Jeon, Doo Sung; Kim, Hong Soo; Rhee, Hak Song [Presbyterian Mediacal center, Cheonju (Korea, Republic of); Kim, Jong Deok [Inje Medical College, Paik Hospital, Pusan (Korea, Republic of)

    1985-10-15

    In a study of primary brain tumors 104 cases having satisfactory clinical, operative and histological proofs were analyzed by computerized tomography at Presbyterian Medical Center from May, 1982 to April 1985. The results were as follows: 1. The male to female ratio of primary brain tumor was 54 : 46. 2. The 2nd decade group (26%) was the most prevalent age group, followed by the 5th decade (16.3%), 1st decade (14.4%) , 3rd decade (12.5%), 4th decade (11.5%), 6th decade (10.6%), 7th decade (8.7%) in that order. 3. The incidence of primary brain tumors was found to be: glioma 64 cases (61.6%) among the GM, the most frequent 17 cases (16.3%), followed by meningioma 12 cases (11.5%), pituitary adenoma 10 cases (9.6%), craniopharyngioma 6 cases (5.8%), pinealoma and germinoma 3 cases (2.9%) respectively, and dermoid cyst 2 cases (1.9%) in that order. 4. The location of the primary brain tumors were as follows: cb. hemisphere (49%) of these 24.5% in parietal region, 11.9% in temporal region, 9.7% in frontal region, 3.0% in occipital region: juxtasella area (16.3%), cerebellar hemisphere (8.7%), parapineal and intraventricle (7.7%) respectively, cerebello-pontine angle area (5.8%), vermis and 4th ventricular region (4.8%). 5. There were no remarkable differences in the findings of pre- and post-contrast CT scanning of primary brain tumors computed with others.

  17. Neurosurgical operating computerized tomographic scanner system

    International Nuclear Information System (INIS)

    Okudera, Hiroshi; Sugita, Kenichiro; Kobayashi, Shigeaki; Kimishima, Sakae; Yoshida, Hisashi.

    1988-01-01

    A neurosurgical operating computerized tomography scanner system is presented. This system has been developed for obtaining intra- and postoperative CT images in the operating room. A TCT-300 scanner (manufactured by the Toshiba Co., Tokyo) is placed in the operating room. The realization of a true intraoperative CT image requires certain improvements in the CT scanner and operating table. To adjust the axis of the co-ordinates of the motor system of the MST-7000 microsurgical operating table (manufactured by the Mizuho Ika Co., Tokyo) to the CT scanner, we have designed an interface and a precise motor system so that the computer of the CT scanner can directly control the movement of the operating table. Furthermore, a new head-fixation system has been designed for producing artifact-free intraoperative CT images. The head-pins of the head-fixation system are made of carbon-fiber bars and titanium tips. A simulation study of the total system in the operating room with the CT scanner, operating table, and head holder using a skull model yielded a degree of error similar to that in the phantom testing of the original scanner. Three patients underwent resection of a glial tumor using this system. Intraoperative CT scans taken after dural opening showed a bulging of the cortex, a shift in the central structure, and a displacement of the cortical subarachnoid spaces under the influence of gravity. With a contrast medium the edge of the surrounding brain after resection was enhanced and the residual tumor mass was demonstrated clearly. This system makes it possible to obtain a noninvasive intraoperative image in a situation where structural shifts are taking place. (author)

  18. Integrated System Validation Usability Questionnaire: Computerized Procedures

    International Nuclear Information System (INIS)

    Garcés, Ma. I.; Torralba, B.

    2015-01-01

    The Research and Development (R&D) project on “Theoretical and Methodological Approaches to Integrated System Validation of Control Rooms, 2014-2015”, in which the research activities described in this report are framed, has two main objectives: to develop the items for an usability methodology conceived as a part of the measurement framework for performance-based control room evaluation that the OECD Halden Reactor Project will test in the experiments planned for 2015; and the statistical analysis of the data generated in the experimental activities of the Halden Man-Machine Laboratory (HAMMLAB) facility, with previous usability questionnaires, in 2010 and 2011. In this report, the procedure designed to meet the first goal of the project is described, in particular, the process followed to identify the items related to operating procedures, both computer and paper-based, one of the elements to be included in the usability questionnaire. Three phases are performed, in the first one, the approaches developed by the United States Nuclear Regulatory Commission, NRC, are reviewed, the models used by the nuclear industry and their technical support organizations, mainly, the Electric Power Research Institute, EPRI, are analyzed, and scientist advances are also explored. In the remaining stages, general and specific guidelines for computerized and paper-based procedures are compared and criteria for the preliminary selection of the items that should be incorporated into the usability questionnaire are defined. This proposal will be reviewed and adapted by the Halden Reactor Project to the design of the specific experiments performed in HAMLAB.

  19. Metal oxide nanostructures as gas sensing devices

    CERN Document Server

    Eranna, G

    2016-01-01

    Metal Oxide Nanostructures as Gas Sensing Devices explores the development of an integrated micro gas sensor that is based on advanced metal oxide nanostructures and is compatible with modern semiconductor fabrication technology. This sensor can then be used to create a compact, low-power, handheld device for analyzing air ambience. The book first covers current gas sensing tools and discusses the necessity for miniaturized sensors. It then focuses on the materials, devices, and techniques used for gas sensing applications, such as resistance and capacitance variations. The author addresses the issues of sensitivity, concentration, and temperature dependency as well as the response and recovery times crucial for sensors. He also presents techniques for synthesizing different metal oxides, particularly those with nanodimensional structures. The text goes on to highlight the gas sensing properties of many nanostructured metal oxides, from aluminum and cerium to iron and titanium to zinc and zirconium. The final...

  20. Test and evaluation of computerized nuclear material accounting methods. Final report

    International Nuclear Information System (INIS)

    1995-01-01

    In accordance with the definition of a Material Balance Area (MBA) as a well-defined geographical area involving an Integral operation, the building housing the BFS-1 and BFS-1 critical facilities is considered to consist of one MBA. The BFS materials are in the form of small disks clad in stainless steel and each disk with nuclear material has its own serial number. Fissile material disks in the BFS MBA can be located at three key monitoring points: BFS-1 facility, BFS-2 facility and main storage of BFS fissile materials (storage 1). When used in the BFS-1 or BFS-2 critical facilities, the fissile material disks are loaded in tubes (fuel rods) forming critical assembly cores. The following specific features of the BFS MBA should be taken into account for the purpose of computerized accounting of nuclear material: (1) very large number of nuclear material items (about 70,000 fissile material items); and (2) periodically very intensive shuffling of nuclear material items. Requirements for the computerized system are determined by basic objectives of nuclear material accounting: (1) providing accurate information on the identity and location of all items in the BFS material balance area; (2) providing accurate information on location and identity of tamper-indicating devices; (3) tracking nuclear material inventories; (4) issuing periodic reports; (5) assisting with the detection of material gains or losses; (6) providing a history of nuclear material transactions; (7) preventing unauthorized access to the system and data falsification. In August 1995, the prototype computerized accounting system was installed on the BFS facility for trial operation. Information on two nuclear material types was entered into the data base: weapon-grade plutonium metal and 36% enriched uranium dioxide. The total number of the weapon-grade plutonium disks is 12,690 and the total number of the uranium dioxide disks is 1,700

  1. The validity and reliability of the handheld SW-100 autokeratometer

    Directory of Open Access Journals (Sweden)

    Eghosasere Iyamu

    2015-07-01

    Full Text Available Background: The agreement of new instruments or clinical tests with other instruments or tests defines the possibility of these being used interchangeably. Aim: To investigate the validity and reliability of the SW-100 autokeratometer using a Bausch & Lomb (B&L keratometer as the ‘gold standard’. Methods: Eighty subjects (80 right eyes aged between 21 and 38 years were recruited. For intra-test repeatability, two measurements of the corneal radius of curvature were taken with the SW-100 and B&L keratometers. Forty of the 80 subjects participated in the inter-test repeatability measurement. Results: Corneal radius of curvature was found to be statistically different between the two instruments (p < 0.001, with the SW-100 providing slightly flatter values of 0.11 mm and 0.05 mm for the horizontal and vertical meridians, respectively, than the B&L keratometer. The average corneal curvature was 0.07 mm flatter with the SW-100 autokeratometer than with the B&L device. Agreement between the SW-100 and B&L keratometers’ axes was 45% within ± 5°, 60.3% within ± 10°, 78.8% within ± 15°, 80.3% within ± 20°, and 88.7% within ± 40°. Intertest repeatability was better for the B&L device than the SW-100 and showed no significant difference between the two sessions. Both instruments demonstrated comparable intrasession repeatability. As such, both instruments were comparatively reliable (per coefficients of repeatability. The range of limits of agreement of ± 0.14 mm (horizontal meridian and ± 0.17 mm (vertical meridian between the SW-100 and B&L devices showed good agreement. Conclusion: The results suggest that the SW-100 autokeratometer is a reliable and objective instrument that, however, provides flatter radii of curvature measurements than the B&L keratometer. A compensating factor incorporated into the instrument could reduce the difference between the two instruments and make them more interchangeable.

  2. Parafoveal retinal cone mosaic imaging in children with ultra-compact switchable SLO/OCT handheld probe (Conference Presentation)

    Science.gov (United States)

    LaRocca, Francesco; Nankivil, Derek; DuBose, Theodore B.; Toth, Cynthia A.; Farsiu, Sina; Izatt, Joseph A.

    2016-03-01

    In vivo photoreceptor imaging has enhanced the way vision scientists and ophthalmologists understand the retinal structure, function, and etiology of numerous retinal pathologies. However, the complexity and large footprint of current systems capable of resolving photoreceptors has limited imaging to patients who are able to sit in an upright position and fixate for several minutes. Unfortunately, this excludes an important fraction of patients including bedridden patients, small children, and infants. Here, we show that our dual-modality, high-resolution handheld probe with a weight of only 94 g is capable of visualizing photoreceptors in supine children. Our device utilizes a microelectromechanical systems (MEMS) scanner and a novel telescope design to achieve over an order of magnitude reduction in size compared to similar systems. The probe has a 7° field of view and a lateral resolution of 8 µm. The optical coherence tomography (OCT) system has an axial resolution of 7 µm and a sensitivity of 101 dB. High definition scanning laser ophthalmoscopy (SLO) and OCT images were acquired from children ranging from 14 months to 12 years of age with and without pathology during examination under anesthesia in the operating room. Parafoveal cone imaging was shown using the SLO arm of this device without adaptive optics using a 3° FOV for the first time in children under 4 years old. This work lays the foundation for pediatric research, which will improve understanding of retinal development, maldevelopment and early onset of diseases at the cellular level during the beginning stages of human growth.

  3. Hand-held triangulation laser profilometer with audio output for blind people Profilométre laser à triangulation tenu en main avec sortie sonare pour non-voyants

    Science.gov (United States)

    Farcy, R.; Damaschini, R.

    1998-06-01

    We describe a device currently under industrial development which will give to the blind a means of three-dimensional space perception. It consists of a 350 g hand-held triangulating laser telemeter including electronic parts and batteries, with auditory feedback either inside the apparatus or close to the ear. The microprocessor unit converts in real time the distance measured by the telemeter into a musical note. Scanning the space with an adequate movement of the hand produces musical lines corresponding to the profiles of the environment. We discuss the optical configuration of the system relative to our first year of clinical experimentation.

  4. Computerized photogrammetry used to calculate the brow position index.

    Science.gov (United States)

    Naif-de-Andrade, Naif Thadeu; Hochman, Bernardo; Naif-de-Andrade, Camila Zirlis; Ferreira, Lydia Masako

    2012-10-01

    The orbital region is of vital importance to facial expression. Brow ptosis, besides having an impact on facial harmony, is a sign of aging. Various surgical techniques have been developed to increase the efficacy of brow-lift surgery. However, no consensus method exists for an objective measurement of the eyebrow position due to the curvature of the face. Therefore, this study aimed to establish a method for measuring the eyebrow position using computerized photogrammetry. For this study, 20 orbital regions of 10 volunteers were measured by direct anthropometry using a digital caliper and by indirect anthropometry (computerized photogrammetry) using standardized digital photographs. Lines, points, and distances were defined based on the position of the anthropometric landmarks endocanthion and exocanthion and then used to calculate the brow position index (BPI). Statistical analysis was performed using Student's t test with a significance level of 5 %. The BPI values obtained by computerized photogrammetric measurements did not differ significantly from those obtained by direct anthropometric measurements (p > 0.05). The mean BPI was 84.89 ± 10.30 for the computerized photogrammetric measurements and 85.27 ± 10.67 for the direct anthropometric measurements. The BPI defined in this study and obtained by computerized photogrammetry is a reproducible and efficient method for measuring the eyebrow position. This journal requires that authors assign a level of evidence to each article.

  5. Computerized videodefecography versus defecography: do we need radiographs?

    Directory of Open Access Journals (Sweden)

    Carlos Walter Sobrado

    Full Text Available CONTEXT AND OBJECTIVE: Defecography has been recognized as a valuable method for evaluating patients with evacuation disorders. It consists of the use of static radiography and fluoroscopy to record different situations within anorectal dynamics. Conventionally, rectal parameters are measured using radiograms. It is rare for fluoroscopy alone to be used. Computer software has been developed with the specific aim of calculating these measurements from digitized videotaped images obtained during fluoroscopy, without the need for radiographic film, thereby developing a computerized videodefecography method. The objective was thus to compare measurements obtained via computerized videodefecography with conventional measurements and to discuss the advantages of the new method. DESIGN AND SETTING: Prospective study at the radiology service of Hospital das Clínicas, Universidade de São Paulo. METHOD: Ten consecutive normal subjects underwent videodefecography. The anorectal angle, anorectal junction, puborectalis muscle length, anal canal length and degree of anal relaxation were obtained via the conventional method (using radiography film and via computerized videodefecography using the ANGDIST software. Measurement and analysis of these parameters was performed by two independent physicians. RESULTS: Statistical analysis confirmed that the measurements obtained through direct radiography film assessment and using digital image analysis (computerized videodefecography were equivalent. CONCLUSIONS: Computerized videodefecography is equivalent to the traditional defecography examination. It has the advantage of offering reduced radiation exposure through saving on the use of radiography.

  6. Application of Handheld Laser-Induced Breakdown Spectroscopy (LIBS) to Geochemical Analysis.

    Science.gov (United States)

    Connors, Brendan; Somers, Andrew; Day, David

    2016-05-01

    While laser-induced breakdown spectroscopy (LIBS) has been in use for decades, only within the last two years has technology progressed to the point of enabling true handheld, self-contained instruments. Several instruments are now commercially available with a range of capabilities and features. In this paper, the SciAps Z-500 handheld LIBS instrument functionality and sub-systems are reviewed. Several assayed geochemical sample sets, including igneous rocks and soils, are investigated. Calibration data are presented for multiple elements of interest along with examples of elemental mapping in heterogeneous samples. Sample preparation and the data collection method from multiple locations and data analysis are discussed. © The Author(s) 2016.

  7. Hand-held transendoscopic robotic manipulators: A transurethral laser prostate surgery case study.

    Science.gov (United States)

    Hendrick, Richard J; Mitchell, Christopher R; Herrell, S Duke; Webster, Robert J

    2015-11-01

    Natural orifice endoscopic surgery can enable incisionless approaches, but a major challenge is the lack of small and dexterous instrumentation. Surgical robots have the potential to meet this need yet often disrupt the clinical workflow. Hand-held robots that combine thin manipulators and endoscopes have the potential to address this by integrating seamlessly into the clinical workflow and enhancing dexterity. As a case study illustrating the potential of this approach, we describe a hand-held robotic system that passes two concentric tube manipulators through a 5 mm port in a rigid endoscope for transurethral laser prostate surgery. This system is intended to catalyze the use of a clinically superior, yet rarely attempted, procedure for benign prostatic hyperplasia. This paper describes system design and experiments to evaluate the surgeon's functional workspace and accuracy using the robot. Phantom and cadaver experiments demonstrate successful completion of the target procedure via prostate lobe resection.

  8. A study of cladding technology on tube wall surface by a hand-held laser torch

    International Nuclear Information System (INIS)

    Terada, Takaya; Nishimura, Akihiko; Oka, Kiyoshi; Moriyama, Taku; Matsuda, Hiroyasu

    2015-01-01

    New maintenance technique was proposed using a hand-held laser torch for aging chemical plants and power plants. The hand-held laser torch was specially designed to be able to access limited tubular space in various cases. A composite-type optical fiberscope was composed of a center fiber for beam delivery and surrounded fibers for visible image delivery. Laser irradiation on a work pieces with the best accuracy of filler wire was carried out. And, we found that the optimized wire-feed speed was 2 mm/s in laser cladding. We succeeded to make a line clad on the inner wall of 23 mm tube. This technique was discussed to be applied to the maintenance for cracks or corrosions of tubes in various harsh environments. (author)

  9. Experience feedback of computerized controlled nuclear power plants

    International Nuclear Information System (INIS)

    Poizat, F.

    2004-01-01

    The N4 step of French PWR-type nuclear power plants is characterized by an instrumentation and control system entirely computerized (operation procedures including normal and accidental operation). Four power plants of this type (Chooz and Civaux sites) of 1450 MWe each were connected to the power grid between August 1996 and December 1999. The achievement of this program make it possible and necessary to carry out an experience feedback about the development, successes and difficulties encountered in order to draw out some lessons for future realizations. This is the aim of this article: 1 - usefulness and difficulties of such an experience feedback: evolution of instrumentation and control systems, necessary cautions; 2 - a successful computerized control: checking of systems operation, advantages, expectations; 3 - efficiency of computerized systems: demonstration of operation safety, profitability; 4 - conclusions and interrogations: system approach instead of 'micro-software' approach, commercial or 'made to measure' products, contract agreement with a supplier, when and how upgrading. (J.S.)

  10. Quality criteria in computerized tomography of the chest

    International Nuclear Information System (INIS)

    Doehring, W.

    1985-01-01

    The quality of thoracical computerized tomography (CT) - like any other CT examination - depends from the quality of the equipment used, from the skill of the examinor and the properties of the patient. Concerning computerized chest tomograms, rapid scan equipment should be used only and slow translation - rotation systems should not be used any more. Whereas the quality of computerized tomograms may be influenced by the patient in the scanning process only, the examining physician will decisively influence the possible informative value of the examination also in the reconstruction of the CT value matrix, in single demonstration of CT values and, possibly, in additional measurement value processing as well as in the interpretation of findings. Use of equipment should always consider the technical potential provided by the equipment to be oriented to the clinical issue, and the conditions preset by the patient. (orig.) [de

  11. Cognitive task analysis and the design of computerized operator aids

    International Nuclear Information System (INIS)

    Andersson, H.

    1985-01-01

    The new technological possibilities have led to the initiation of many projects for the design and evaluation of computerized operator support systems to be implemented in nuclear power plant control rooms. A typical finding so far has been that operators often have a positive attitude towards such systems but still don't use them very much, mostly because they find almost the same information on the conventional control boards which they are accustomed to use. Still, however, there is a widely shared belief that conventional control rooms have short-comings that make the use of computerized aids necessary. One reason for the limited success so far is that the new systems often are poorly integrated with the existing conventional instrumentation and with the working procedures. The reluctance to use new computer based aids, despite their nice features, is therefore probably caused by an inadequate task analysis made prior to the design of these computerized operator support systems

  12. Computerized access to materials data. A progress report

    International Nuclear Information System (INIS)

    Rumble, J. Jr.

    1985-01-01

    As the effort to build a comprehensive computerized materials data system grows, it becomes more obvious that the benefits will be far-reaching. During this workshop, the enthusiasm of the participants grew steadily until the questions became not''What,'' but ''When?''. The engineering community within the United States has banded together many times to advance progress in engineering capability. The computerized materials data system requires such an effort, and the rewards will be substantial. Chapter 3 identifies changes in the use of materials data in the Nuclear Power Industry. Chapter 4 describes the EPRI experience in building computerized materials databases. In Chapter 5, the National Materials Property Data Network is discussed. The next four chapters present summaries of the workshop discussions and its conclusions. Chapter 6 discusses the content of the proposed system, Chapter 7 its size and the data sources, and Chapter 8 the user interfaces and system capabilities. In Chapter 9, ways of making further progress are outlined

  13. Current Human Reliability Analysis Methods Applied to Computerized Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Ronald L. Boring

    2012-06-01

    Computerized procedures (CPs) are an emerging technology within nuclear power plant control rooms. While CPs have been implemented internationally in advanced control rooms, to date no US nuclear power plant has implemented CPs in its main control room (Fink et al., 2009). Yet, CPs are a reality of new plant builds and are an area of considerable interest to existing plants, which see advantages in terms of enhanced ease of use and easier records management by omitting the need for updating hardcopy procedures. The overall intent of this paper is to provide a characterization of human reliability analysis (HRA) issues for computerized procedures. It is beyond the scope of this document to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper serves as a review of current HRA as it may be used for the analysis and review of computerized procedures.

  14. Handheld mechanical nociceptive threshold testing in dairy cows – intra-individual variation, inter-observer agreement and variation over time

    Science.gov (United States)

    Raundal, Peter M; Andersen, Pia H; Toft, Nils; Forkman, Björn; Munksgaard, Lene; Herskin, Mette S

    2014-01-01

    Objective To examine the use of handheld methodology to assess mechanical nociceptive threshold (MNT) on cows kept loose-housed. Study design Prospective randomized partial cross-over experimental study. A one-factor (test day) design was used to evaluate MNT over time. Animals One hundred and fifteen healthy, loose-housed Danish Holstein cattle. Methods We evaluated intra-individual variation, inter-observer agreement and variation over time of MNT using two handheld devices and two stimulation sites. Mechanical, ramped stimulations were performed with an algometer (6.5 mm diameter steel probe, 0–10.0 kgf) or an electronic von Frey device (plastic tip with diameter 0.8 mm, 0–1000 gf). Each cow received 5–6 consecutive stimulations within a 2 × 5 cm skin area on the dorsal or lateral aspect of the left third metatarsus until an avoidance reaction occurred. We investigated the difference in precision [expressed as coefficient of variation (CV)] between the combinations of devices and stimulation sites. The inter-observer agreement and the difference in MNT between test day 1, 3, 7, 10 and 24 were investigated for selected combinations. Data were analysed in mixed models and Bland-Altman as relevant. Results The CVs did not differ [range 0.34–0.52 (p = 0.1)]. Difference between observers (95% limits) was 0.2 kgf (2.8) and 4 gf (369) for the algometer and von Frey device, respectively. Mechanical nociceptive threshold increased from 361 on test day one to 495 gf on test day 24 (p < 0.01). Conclusion and clinical relevance All methods showed a high degree of intra-individual variation, and no combination of device and stimulation site showed superior precision. Mean difference between observers was low, and MNT was not consistent over time. Further development of the methods is required before they can be used in research to investigate possible relations between claw lesions and hyperalgesia. PMID:24734991

  15. Development of computerized dose planning system and applicator for high dose rate remote afterloading irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, T. J. [Keimyung Univ., Taegu (Korea); Kim, S. W. [Fatima Hospital, Taegu (Korea); Kim, O. B.; Lee, H. J.; Won, C. H. [Keimyung Univ., Taegu (Korea); Yoon, S. M. [Dong-a Univ., Pusan (Korea)

    2000-04-01

    To design and fabricate of the high dose rate source and applicators which are tandem, ovoids and colpostat for OB/Gyn brachytherapy includes the computerized dose planning system. Designed the high dose rate Ir-192 source with nuclide atomic power irradiation and investigated the dose characteristics of fabricated brachysource. We performed the effect of self-absorption and determining the gamma constant and output factor and determined the apparent activity of designed source. he automated computer planning system provided the 2D distribution and 3D includes analysis programs. Created the high dose rate source Ir-192, 10 Ci(370GBq). The effective attenuation factor from the self-absorption and source wall was examined to 0.55 of the activity of bare source and this factor is useful for determination of the apparent activity and gamma constant 4.69 Rcm{sup 2}/mCi-hr. Fabricated the colpostat was investigated the dose distributions of frontal, axial and sagittal plane in intra-cavitary radiation therapy for cervical cancer. The reduce dose at bladder and rectum area was found about 20 % of original dose. The computerized brachytherapy planning system provides the 2-dimensional isodose and 3-D include the dose-volume histogram(DVH) with graphic-user-interface mode. emoted afterloading device was built for experiment of created Ir-192 source with film dosimetry within {+-}1 mm discrepancy. 34 refs., 25 figs., 11 tabs. (Author)

  16. The importance of proper administration and interpretation of neuropsychological baseline and postconcussion computerized testing.

    Science.gov (United States)

    Moser, Rosemarie Scolaro; Schatz, Philip; Lichtenstein, Jonathan D

    2015-01-01

    Media coverage, litigation, and new legislation have resulted in a heightened awareness of the prevalence of sports concussion in both adult and youth athletes. Baseline and postconcussion testing is now commonly used for the assessment and management of sports-related concussion in schools and in youth sports leagues. With increased use of computerized neurocognitive sports concussion testing, there is a need for standards for proper administration and interpretation. To date, there has been a lack of standardized procedures by which assessments are administered. More specifically, individuals who are not properly trained often interpret test results, and their methods of interpretation vary considerably. The purpose of this article is to outline factors affecting the validity of test results, to provide examples of misuse and misinterpretation of test results, and to communicate the need to administer testing in the most effective and useful manner. An increase in the quality of test administration and application may serve to decrease the prevalence of invalid test results and increase the accuracy and utility of baseline test results if an athlete sustains a concussion. Standards for test use should model the American Psychological Association and Centers for Disease Control and Prevention guidelines, as well as the recent findings of the joint position paper on computerized neuropsychological assessment devices.

  17. Leakage and scattered radiation from hand-held dental x-ray unit

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Kyung [Dankook Univ. School of Dentistry, Seoul (Korea, Republic of)

    2007-06-15

    To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR {iota}{iota}{iota} was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of hand-held dental X-ray unit were 70 kVp, 3 mA , 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. The mean dose at the hand level when human skull DXTTR {iota}{iota}{iota} was exposed with portable X-ray unit 6.39 {mu}Gy, and the mean dose with fixed X-ray unit 3.03 {mu}Gy (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was 2.97 {mu}Gy and with fixed X-ray unit the mean dose was 0.68 {mu}Gy (p<0.01). The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography.

  18. Precise intraoperative location of gastrointestinal bleeding with a hand-held counter. Work in progress

    International Nuclear Information System (INIS)

    Williamson, M.R.; Boyd, C.M.; McGuire, E.L.

    1986-01-01

    The nuclear medicine bleeding scan is frequently insufficient to locate sites of bleeding precisely, in spite of its great sensitivity. A small, hand-held Geiger-Mueller counter, placed directly on exposed intestine in the operating room, enables precise location of the probable bleeding site. In three patients, the technique allowed a minimal amount of intestine to be resected, distinguished between large- and small-intestinal hemorrhage, and eliminated other foci as sites of bleeding.A

  19. Leakage and scattered radiation from hand-held dental x-ray unit

    International Nuclear Information System (INIS)

    Kim, Eun Kyung

    2007-01-01

    To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR ΙΙΙ was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of hand-held dental X-ray unit were 70 kVp, 3 mA , 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. The mean dose at the hand level when human skull DXTTR ΙΙΙ was exposed with portable X-ray unit 6.39 μGy, and the mean dose with fixed X-ray unit 3.03 μGy (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was 2.97 μGy and with fixed X-ray unit the mean dose was 0.68 μGy (p<0.01). The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography

  20. Multimodal ophthalmic imaging using handheld spectrally encoded coherence tomography and reflectometry (SECTR)

    Science.gov (United States)

    Leeburg, Kelsey C.; El-Haddad, Mohamed T.; Malone, Joseph D.; Terrones, Benjamin D.; Tao, Yuankai K.

    2018-02-01

    Scanning laser ophthalmoscopy (SLO) provides high-speed, noninvasive en face imaging of the retinal fundus. Optical coherence tomography (OCT) is the current "gold-standard" for ophthalmic diagnostic imaging and enables depth-resolved visualization of ophthalmic structures and image-based surrogate biomarkers of disease. We present a compact optical and mechanical design for handheld spectrally encoded coherence tomography and reflectometry (SECTR) for multimodality en face spectrally encoded reflectometry (SER) and cross-sectional OCT imaging. We custom-designed a double-pass telecentric scan lens, which halves the size of 4-f optical relays and allowed us to reduce the footprint of our SECTR scan-head by a factor of >2.7x (volume) over our previous design. The double-pass scan lens was optimized for diffraction-limited performance over a +/-10° scan field. SECTR optics and optomechanics were combined in a compact rapid-prototyped enclosure with dimensions 87 x 141.8 x 137 mm (w x h x d). SECTR was implemented using a custom-built 400 kHz 1050 nm swept-source. OCT and SER were simultaneously digitized on dual input channels of a 4 GS/s digitizer at 1.4 GS/s per channel. In vivo human en face SER and cross-sectional OCT images were acquired at 350 fps. OCT volumes of 1000 B-scans were acquired in 2.86 s. We believe clinical translation of our compact handheld design will benefit point-of-care ophthalmic diagnostics in patients who are unable to be imaged on conventional slit-lamp based systems, such as infants and the bedridden. When combined with multi-volumetric registration methods, handheld SECTR will have advantages in motion-artifact free imaging over existing handheld technologies.