WorldWideScience

Sample records for hand-held gamma-detecting probe

  1. A hand-held beta imaging probe for FDG.

    Science.gov (United States)

    Singh, Bipin; Stack, Brendan C; Thacker, Samta; Gaysinskiy, Valeriy; Bartel, Twyla; Lowe, Val; Cool, Steven; Entine, Gerald; Nagarkar, Vivek

    2013-04-01

    Advances in radiopharmaceuticals and clinical understanding have escalated the use of intraoperative gamma probes in surgery. However, most probes on the market are non-imaging gamma probes that suffer from the lack of ancillary information of the surveyed tissue area. We have developed a novel, hand-held digital Imaging Beta Probe™ (IBP™) to be used in surgery in conjunction with beta-emitting radiopharmaceuticals such as (18)FDG, (131)I and (32)P for real-time imaging of a surveyed area with higher spatial resolution and sensitivity and greater convenience than existing instruments. We describe the design and validation of a hand-held beta probe intended to be used as a visual mapping device to locate and confirm excision of (18)FDG-avid primary tumors and metastases in an animal model. We have demonstrated a device which can generate beta images from (18)FDG avid lesions in an animal model. It is feasible to image beta irradiation in animal models of cancer given (18)FDG. This technology may be applied to clinical mapping of tumors and/or their metastases in the operating room. Visual image depiction of malignancy may aid the surgeon in localization and excision of lesions of interest.

  2. 'RIG'- surgical gamma probe for early breast cancer detection

    International Nuclear Information System (INIS)

    Walinjkar, P.B.; Singh, Gursharan; Kumar, Umesh; Pendharkar, A.S.; Choudhary, P.S.

    2004-01-01

    Breast cancer is one of the most common cancers in women, which if detected in early stage can be effectively treated and cured. Early detection is carried out by collecting a sentinel lymph node (SLN) and testing it for cancer. The surgical gamma probe is a hand-held device used in the localization of SLN. It enables the localization of the active node. Isotope Applications Division, BARC has developed indigenously a RIG Surgical Gamma Probe in consultation with the doctors from Rajiv Gandhi Cancer Institute and Research Centre, New Delhi. The system consists of microcomputer-based gamma counting system that displays the number of pulses detected by the probe in counts per second and has an audible signal in direct correlation with the count density. The detector probe is based on the scintillation detector housed in a stainless steel housing with lead collimator. The physical parameters are a high sensitivity of 5000 cps/MBq at probe tip with good spatial resolution. The performance of this probe was clinically evaluated on the basis of spatial resolution and accuracy to detect the active node. (author)

  3. Development of a novel gamma probe for detecting radiation direction

    Science.gov (United States)

    Pani, R.; Pellegrini, R.; Cinti, M. N.; Longo, M.; Donnarumma, R.; D'Alessio, A.; Borrazzo, C.; Pergola, A.; Ridolfi, S.; De Vincentis, G.

    2016-01-01

    Spatial localization of radioactive sources is currently a main issue interesting different fields, including nuclear industry, homeland security as well as medical imaging. It is currently achieved using different systems, but the development of technologies for detecting and characterizing radiation is becoming important especially in medical imaging. In this latter field, radiation detection probes have long been used to guide surgery, thanks to their ability to localize and quantify radiopharmaceutical uptake even deep in tissue. Radiolabelled colloid is injected into, or near to, the tumor and the surgeon uses a hand-held radiation detector, the gamma probe, to identify lymph nodes with radiopharmaceutical uptkake. The present work refers to a novel scintigraphic goniometric probe to identify gamma radiation and its direction. The probe incorporates several scintillation crystals joined together in a particular configuration to provide data related to the position of a gamma source. The main technical characteristics of the gamma locator prototype, i.e. sensitivity, spatial resolution and detection efficiency, are investigated. Moreover, the development of a specific procedure applied to the images permits to retrieve the source position with high precision with respect to the currently used gamma probes. The presented device shows a high sensitivity and efficiency to identify gamma radiation taking a short time (from 30 to 60 s). Even though it was designed for applications in radio-guided surgery, it could be used for other purposes, as for example homeland security.

  4. Development of a novel gamma probe for detecting radiation direction

    International Nuclear Information System (INIS)

    Pani, R.; Pellegrini, R.; Cinti, M.N.; Longo, M.; Donnarumma, R.; Borrazzo, C.; D'Alessio, A.; Pergola, A.; Ridolfi, S.; Vincentis, G. De

    2016-01-01

    Spatial localization of radioactive sources is currently a main issue interesting different fields, including nuclear industry, homeland security as well as medical imaging. It is currently achieved using different systems, but the development of technologies for detecting and characterizing radiation is becoming important especially in medical imaging. In this latter field, radiation detection probes have long been used to guide surgery, thanks to their ability to localize and quantify radiopharmaceutical uptake even deep in tissue. Radiolabelled colloid is injected into, or near to, the tumor and the surgeon uses a hand-held radiation detector, the gamma probe, to identify lymph nodes with radiopharmaceutical uptkake. The present work refers to a novel scintigraphic goniometric probe to identify gamma radiation and its direction. The probe incorporates several scintillation crystals joined together in a particular configuration to provide data related to the position of a gamma source. The main technical characteristics of the gamma locator prototype, i.e. sensitivity, spatial resolution and detection efficiency, are investigated. Moreover, the development of a specific procedure applied to the images permits to retrieve the source position with high precision with respect to the currently used gamma probes. The presented device shows a high sensitivity and efficiency to identify gamma radiation taking a short time (from 30 to 60 s). Even though it was designed for applications in radio-guided surgery, it could be used for other purposes, as for example homeland security

  5. The Complimentary Role of Methoxy-Isobutyl-Isonitrile and Hand-Held Gamma Probe in Adamantinoma

    Science.gov (United States)

    Maharaj, Masha; Korowlay, Nisaar; Ellmann, Prof

    2016-01-01

    Adamantinoma is a rare locally aggressive osteolytic tumor that is found 90% of the time in the diaphysis of the tibia with the remaining lesions found in the fibula and long tubular bones. A case of adamantinoma of the tibia is presented. The added value of nuclear medicine investigations in the workup of this patient is described. A three-phase whole body 99mTc-methylene diphosphonate bone and a whole body 99mTc-methoxy-isobutyl-isonitrile scans were complimentary in the demarcation of viable bone tumor and the assessment of the remainder of the bone and soft tissue to exclude other sites. Intra-operative assistance with a hand-held gamma probe, guided the biopsy of the most metabolically active tumor tissue. Histology revealed a biphasic tumor composed of epithelial and fibrous components, in keeping with an adamantinoma. PMID:26912979

  6. Gamma-ray detectors for intelligent, hand-held radiation monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1983-01-01

    Small radiation detectors based on HgI 2 , bismuth germanate (BGO), plastic, or NaI(Tl) detector materials were evaluated for use in small, lighweight radiation monitors. The two denser materials, HgI 2 and BGO, had poor resolution at low-energy and thus performed less well than NaI(Tl) in detecting low-energy gamma rays from bare, enriched uranium. The plastic scintillator, a Compton recoil detector, also performed less well at low gamma-ray energy. Two small NaI(Tl) detectors were suitable for detecting bare uranium and sheilded plutonium. One became part of a new lightweight hand-held monitor and the other found uses as a pole-mounted detector for monitoring hard-to-reach locations

  7. Potential role of a new hand-held miniature gamma camera in performing minimally invasive parathyroidectomy

    Energy Technology Data Exchange (ETDEWEB)

    Ortega, Joaquin; Lledo, Salvador [University of Valencia, Clinic University Hospital, Department of Surgery, Valencia (Spain); Ferrer-Rebolleda, Jose [Clinic University Hospital, Department of Nuclear Medicine, Valencia (Spain); Cassinello, Norberto [Clinic University Hospital, Unit of Endocrinologic and Bariatric Surgery, Valencia (Spain)

    2007-02-15

    Sestamibi scans have increased the use of minimally invasive parathyroidectomy (MIP) to treat primary hyperparathyroidism (PHPT) when caused by a parathyroid single adenoma. The greatest concern for surgeons remains the proper identification of pathological glands in a limited surgical field. We have studied the usefulness of a new hand-held miniature gamma camera (MGC) when used intraoperatively to locate parathyroid adenomas. To our knowledge this is the first report published on this subject in the scientific literature. Five patients with PHPT secondary to a single adenoma, positively diagnosed by preoperative sestamibi scans, underwent a MIP. A gamma probe for radioguided surgery and the new hand-held MGC were used consecutively to locate the pathological glands. This new MGC has a module composed of a high-resolution interchangeable collimator and a CsI(Na) scintillating crystal. It has dimensions of around 15 cm x 8 cm x 9 cm and weighs 1 kg. The intraoperative assay of PTH (ioPTH) was used to confirm the complete resection of pathological tissue. All cases were operated on successfully by a MIP. The ioPTH confirmed the excision of all pathological tissues. The MGC proved its usefulness in all patients, even in a difficult case in which the first attempt with the gamma probe failed. In all cases it offered real-time accurate intraoperative images. The hand-held MGC is a useful instrument in MIP for PHPT. It may be used to complement the standard tools used to date, or may even replace them, at least in selected cases of single adenomas. (orig.)

  8. Potential role of a new hand-held miniature gamma camera in performing minimally invasive parathyroidectomy

    International Nuclear Information System (INIS)

    Ortega, Joaquin; Lledo, Salvador; Ferrer-Rebolleda, Jose; Cassinello, Norberto

    2007-01-01

    Sestamibi scans have increased the use of minimally invasive parathyroidectomy (MIP) to treat primary hyperparathyroidism (PHPT) when caused by a parathyroid single adenoma. The greatest concern for surgeons remains the proper identification of pathological glands in a limited surgical field. We have studied the usefulness of a new hand-held miniature gamma camera (MGC) when used intraoperatively to locate parathyroid adenomas. To our knowledge this is the first report published on this subject in the scientific literature. Five patients with PHPT secondary to a single adenoma, positively diagnosed by preoperative sestamibi scans, underwent a MIP. A gamma probe for radioguided surgery and the new hand-held MGC were used consecutively to locate the pathological glands. This new MGC has a module composed of a high-resolution interchangeable collimator and a CsI(Na) scintillating crystal. It has dimensions of around 15 cm x 8 cm x 9 cm and weighs 1 kg. The intraoperative assay of PTH (ioPTH) was used to confirm the complete resection of pathological tissue. All cases were operated on successfully by a MIP. The ioPTH confirmed the excision of all pathological tissues. The MGC proved its usefulness in all patients, even in a difficult case in which the first attempt with the gamma probe failed. In all cases it offered real-time accurate intraoperative images. The hand-held MGC is a useful instrument in MIP for PHPT. It may be used to complement the standard tools used to date, or may even replace them, at least in selected cases of single adenomas. (orig.)

  9. An improved hand-held four-detector gamma-probe for radioassisted oncological surgery

    CERN Document Server

    Dusi, W; Bollini, D; Moroni, C; Ricard, M

    2000-01-01

    The performance of an improved intraoperative gamma-probe for radioassisted oncological surgery is presented and discussed. The probe is based on a square array of four 5x5 mm sup 2 coplanar CdTe room temperature semiconductor detectors and each detector has an independent read out electronic chain, allowing an original handling of the signal. Therefore, the search for gamma-emission hot points may be carried out in two different, independent ways: (1) Finding out the position of the probe corresponding to the maximum value of the total counting rate, on the basis of a trial and error procedure (typical for the conventional probe; (2) Finding out the position of the probe where both the differences between the counting rate performed by orthogonal, adjacent halves of the array vanish (differential method). This makes the new probe sensitive to the bidimensional gradient of the gamma-ray flux, measured on the scanned plane. Furthermore, the algebraic sign of the difference indicates in which direction the prob...

  10. Neurosurgical hand-held optical coherence tomography (OCT) forward-viewing probe

    Science.gov (United States)

    Sun, Cuiru; Lee, Kenneth K. C.; Vuong, Barry; Cusimano, Michael; Brukson, Alexander; Mariampillai, Adrian; Standish, Beau A.; Yang, Victor X. D.

    2012-02-01

    A prototype neurosurgical hand-held optical coherence tomography (OCT) imaging probe has been developed to provide micron resolution cross-sectional images of subsurface tissue during open surgery. This new ergonomic hand-held probe has been designed based on our group's previous work on electrostatically driven optical fibers. It has been packaged into a catheter probe in the familiar form factor of the clinically accepted Bayonet shaped neurosurgical non-imaging Doppler ultrasound probes. The optical design was optimized using ZEMAX simulation. Optical properties of the probe were tested to yield an ~20 um spot size, 5 mm working distance and a 3.5 mm field of view. The scan frequency can be increased or decreased by changing the applied voltage. Typically a scan frequency of less than 60Hz is chosen to keep the applied voltage to less than 2000V. The axial resolution of the probe was ~15 um (in air) as determined by the OCT system. A custom-triggering methodology has been developed to provide continuous stable imaging, which is crucial for clinical utility. Feasibility of this probe, in combination with a 1310 nm swept source OCT system was tested and images are presented to highlight the usefulness of such a forward viewing handheld OCT imaging probe. Knowledge gained from this research will lay the foundation for developing new OCT technologies for endovascular management of cerebral aneurysms and transsphenoidal neuroendoscopic treatment of pituitary tumors.

  11. A hand-held imaging probe for radio-guided surgery: physical performance and preliminary clinical experience

    International Nuclear Information System (INIS)

    Pitre, S.; Menard, L.; Charon, Y.; Solal, M.; Garbay, J.R.

    2003-01-01

    Improvements in the specificity of radiopharmaceutical compounds have been paralleled by an upsurge of interest in developing small detectors to assist surgeons in localizing tumour tissue during surgery. This study reports the main technical features and physical characteristics of a new hand-held gamma camera dedicated to accurate and real-time intra-operative imaging. First clinical experience is also reported. The POCI (Per-operative Compact Imager) camera consists of a head module composed of a high-resolution interchangeable lead collimator and a CsI(Na) crystal plate optically coupled to an intensified position-sensitive diode. The current prototype has a 40-mm diameter field of view, an outer diameter of 9.5 cm, a length of 9 cm and a weight of 1.2 kg. Overall detector imaging characteristics were evaluated by technetium-99m phantom measurements. Three patients with breast cancer previously scheduled to undergo sentinel lymph node detection were selected for the preliminary clinical experience. Preoperative images of the lymphatic basin obtained using the POCI camera were compared with conventional transcutaneous explorations using a non-imaging gamma probe. The full-width at half-maximum (FWHM) spatial resolution was investigated in both air and scattering medium; when the phantom was placed in contact with the collimator, the POCI camera exhibited a 3.2 mm FWHM. The corresponding sensitivity was 290 cps/MBq. The preliminary clinical results showed that POCI was able to predict the number and location of all SLNs. In one case, two deep radioactive nodes missed by the gamma probe were detected on the intra-operative images. This very initial experience demonstrates that the physical performance of the POCI camera is adequate for radio-guided surgery. These results are sufficiently encouraging to prompt further evaluation studies designed to determine the specific and optimal clinical role of intra-operative imaging devices

  12. Janus probe, a detection system for high energy reactor gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Gold, R.; Kaiser, B.J.

    1980-03-01

    In reactor environments, gamma-ray spectra are continuous and the absolute magnitude as well as the general shape of the gamma continuum are of paramount importance. Consequently, conventional methods of gamma-ray detection are not suitable for in-core gamma-ray spectrometry. To meet these specific needs, a method of continuous gamma-ray spectrometry, namely Compton Recoil Gamma-Ray Spectrometry, was developed for in-situ observations of reactor environments. A new gamma-ray detection system has been developed which extends the applicability of Compton Recoil Gamma-Ray Spectrometry up to roughly 7 MeV. This detection system is comprised of two separate Si(Li) detectors placed face-to-face. Hence this new detection system is called the Janus probe. Also shown is the block diagram of pulse processing instrumentation for the Janus probe. This new gamma probe not only extends the upper energy limit of in-core gamma-ray spectrometry, but in addition possesses other fundamental advantages

  13. Direction-Sensitive Hand-Held Gamma-Ray Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mukhopadhyay, S.

    2012-10-04

    A novel, light-weight, hand-held gamma-ray detector with directional sensitivity is being designed. The detector uses a set of multiple rings around two cylindrical surfaces, which provides precise location of two interaction points on two concentric cylindrical planes, wherefrom the source location can be traced back by back projection and/or Compton imaging technique. The detectors are 2.0 × 2.0 mm europium-doped strontium iodide (SrI2:Eu2+) crystals, whose light output has been measured to exceed 120,000 photons/MeV, making it one of the brightest scintillators in existence. The crystal’s energy resolution, less than 3% at 662 keV, is also excellent, and the response is highly linear over a wide range of gamma-ray energies. The emission of SrI2:Eu2+ is well matched to both photo-multiplier tubes and blue-enhanced silicon photodiodes. The solid-state photomultipliers used in this design (each 2.0 × 2.0 mm) are arrays of active pixel sensors (avalanche photodiodes driven beyond their breakdown voltage in reverse bias); each pixel acts as a binary photon detector, and their summed output is an analog representation of the total photon energy, while the individual pixel accurately defines the point of interaction. A simple back-projection algorithm involving cone-surface mapping is being modeled. The back projection for an event cone is a conical surface defining the possible location of the source. The cone axis is the straight line passing through the first and second interaction points.

  14. Perceiving the vertical distances of surfaces by means of a hand-held probe.

    Science.gov (United States)

    Chan, T C; Turvey, M T

    1991-05-01

    Nine experiments were conducted on the haptic capacity of people to perceive the distances of horizontal surfaces solely on the basis of mechanical stimulation resulting from contacting the surfaces with a vertically held rod. Participants touched target surfaces with rods inside a wooden cabinet and reported the perceived surface location with an indicator outside the cabinet. The target surface, rod, and the participant's hand were occluded, and the sound produced in exploration was muffled. Properties of the probe (length, mass, moment of inertia, center of mass, and shape) were manipulated, along with surface distance and the method and angle of probing. Results suggest that for the most common method of probing, namely, tapping, perceived vertical distance is specific to a particular relation among the rotational inertia of the probe, the distance of the point of contact with the surface from the probe's center of percussion, and the inclination at contact of the probe to the surface. They also suggest that the probe length and the distance probed are independently perceivable. The results were discussed in terms of information specificity versus percept-percept coupling and parallels between selective attention in haptic and visual perception.

  15. Measuring thyroid uptake with hand-held radiation monitors

    International Nuclear Information System (INIS)

    Deschamps, M.

    1987-04-01

    With the use of Iodine 123, 125 and 131 and some compounds of Technetium-99 m, a fraction of the isotopes can be trapped in the thyroid of the technicians. We used the hand-held radiation contamination or survey meters of the nine (9) Nuclear medicine departments we visited to see if they were adequate for the evaluation of thyroid uptake of the users. Measurements on a neck-phanton helped us to determine a minimum detectable activity for each isotope. We were then able to check if the measurements of investigations and action levels were possible. None of the hand-held radiation monitors are completely satisfactory for the measure of thyroid uptake of the user. We discuss a class of equipment capable of measuring radiation emissions at the investigation level. Measurement at the action level is possible with meters having scintillation or proportional probes but none of them permits the discrimination in energy required for a quantitative evaluation of the radioisotopes used

  16. Preliminary evaluation of intraoperative gamma probe detection of the sentinel node

    Energy Technology Data Exchange (ETDEWEB)

    Sierralta, M P; Jofre, M J [Nuclear Medicine Department, Military Hospital, Santiago (Chile); Iglesis, R; Schwartz, R; Gomez, L; Velez, R [Surgery Department, Military Hospital, Santiago (Chile); Sandoval, R [Pathology Department, Military Hospital, Santiago (Chile)

    2002-09-01

    Introduction: The resurgence of the lymphoscintigraphy with the sentinel node concept and the availability of the intraoperative gamma probe have been proposed to avoid the morbidity of an unnecessary regional node dissection. The aim of the study was to evaluate the intraoperative gamma probe use after lymphoscintigraphy for the localization of the sentinel node. Material and methods: Twenty-nine patients were studied, 18 females (62%), mean age 60 {+-} 19 y.o. (range 24-86 y.o.) at the Military Hospital Nuclear Medicine Department. The reference diagnoses were 66% malignant melanoma, 21 % breast cancer, 10 % head and neck cancer and 3% vulvae cancer. Lymphoscintigraphs were performed with Tc99m-Dextran injected intradermally in four points around the primary lesion or around the biopsy site (for melanoma 500 microCi each one; for breast and head and neck 200 microCi each one). Afterwards, dynamic images were taken, followed by intraoperative gamma probe investigations in order to localize and remove the sentinel node. Additionally, isosulfan blue was injected before the surgery was made. Results: Lymphoscintigraphy was positive to detect sentinel node(s) in 20 patients (69%). During the surgery, 40 sentinel nodes were detected. In 33 cases, the intraoperative gamma probe was performed, of which 88 % were radioactives. In 35 nodes, the isosulfan blue was injected, of which 80 % were dyed. The correlation between both techniques was 75 %. The histology study of 37 samples demonstrated that 86% (n=32) were truly ganglionar nodes. Conclusion: The intraoperative gamma probe after lymphoscintigraphy is a useful technique for the localization of the sentinel node.

  17. Preliminary evaluation of intraoperative gamma probe detection of the sentinel node

    International Nuclear Information System (INIS)

    Sierralta, M.P.; Jofre, M.J.; Iglesis, R.; Schwartz, R.; Gomez, L.; Velez, R.; Sandoval, R.

    2002-01-01

    Introduction: The resurgence of the lymphoscintigraphy with the sentinel node concept and the availability of the intraoperative gamma probe have been proposed to avoid the morbidity of an unnecessary regional node dissection. The aim of the study was to evaluate the intraoperative gamma probe use after lymphoscintigraphy for the localization of the sentinel node. Material and methods: Twenty-nine patients were studied, 18 females (62%), mean age 60 ± 19 y.o. (range 24-86 y.o.) at the Military Hospital Nuclear Medicine Department. The reference diagnoses were 66% malignant melanoma, 21 % breast cancer, 10 % head and neck cancer and 3% vulvae cancer. Lymphoscintigraphs were performed with Tc99m-Dextran injected intradermally in four points around the primary lesion or around the biopsy site (for melanoma 500 microCi each one; for breast and head and neck 200 microCi each one). Afterwards, dynamic images were taken, followed by intraoperative gamma probe investigations in order to localize and remove the sentinel node. Additionally, isosulfan blue was injected before the surgery was made. Results: Lymphoscintigraphy was positive to detect sentinel node(s) in 20 patients (69%). During the surgery, 40 sentinel nodes were detected. In 33 cases, the intraoperative gamma probe was performed, of which 88 % were radioactives. In 35 nodes, the isosulfan blue was injected, of which 80 % were dyed. The correlation between both techniques was 75 %. The histology study of 37 samples demonstrated that 86% (n=32) were truly ganglionar nodes. Conclusion: The intraoperative gamma probe after lymphoscintigraphy is a useful technique for the localization of the sentinel node

  18. New portable hand-held radiation instruments for measurements and monitoring

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1987-01-01

    Hand-held radiation monitors are often used to search pedestrians and motor vehicles for special nuclear material (SNM) as part of a physical protection plan for nuclear materials. Recently, the Los Alamos Advanced Nuclear Technology group has commercialized an improved hand-held monitor that can be used for both physical-protection monitoring and verification measurements in nuclear material control and waste management. The new monitoring instruments are smaller and lighter; operate much longer on a battery charge; are available with NaI(Tl) or neutron and gamma-ray sensitive plastic scintillation detectors; and are less expensive than other comparable instruments. They also have a second operating mode for making precise measurements over counting times as long as 99 s. This mode permits making basic verification measurements that may be needed before transporting nuclear material or waste outside protected areas. Improved verification measurements can be made with a second new hand-held instrument that has a stabilized detector and three separate gamma-ray energy windows to obtain spectral information for SNM quantity, enrichment, or material-type verification

  19. Gen-2 Hand-Held Optical Imager towards Cancer Imaging: Reflectance and Transillumination Phantom Studies

    Directory of Open Access Journals (Sweden)

    Anuradha Godavarty

    2012-02-01

    Full Text Available Hand-held near-infrared (NIR optical imagers are developed by various researchers towards non-invasive clinical breast imaging. Unlike these existing imagers that can perform only reflectance imaging, a generation-2 (Gen-2 hand-held optical imager has been recently developed to perform both reflectance and transillumination imaging. The unique forked design of the hand-held probe head(s allows for reflectance imaging (as in ultrasound and transillumination or compressed imaging (as in X-ray mammography. Phantom studies were performed to demonstrate two-dimensional (2D target detection via reflectance and transillumination imaging at various target depths (1–5 cm deep and using simultaneous multiple point illumination approach. It was observed that 0.45 cc targets were detected up to 5 cm deep during transillumination, but limited to 2.5 cm deep during reflectance imaging. Additionally, implementing appropriate data post-processing techniques along with a polynomial fitting approach, to plot 2D surface contours of the detected signal, yields distinct target detectability and localization. The ability of the gen-2 imager to perform both reflectance and transillumination imaging allows its direct comparison to ultrasound and X-ray mammography results, respectively, in future clinical breast imaging studies.

  20. Development of voltage sensitivity preamplifier to application in radioguided surgical probe

    International Nuclear Information System (INIS)

    Costa, Fabio Eduardo da; Rela, Paulo Roberto; Hamada, Margarida Mizue

    2005-01-01

    The methods of nuclear medicine are increasing used to complement standard diagnostic examinations. Some of these are radioguided detection of the sentinel lymph node (SN) and the radioguided localization of occult lesions. The SN technique is used in a small-size breast carcinoma and involves the identification, removal and immediate histological examination. Specifically, particles of colloidal human serum albumin are labelled with low activities of 99m Tc and are inoculated into the breast lesion or close in the case of SN biopsy. Subsequently, a hand-held gamma-ray detecting probe with reduced dimensions is used to locate the lesion or the SN as a hot spot and guide its surgical removal. Many techniques can be used for gamma-ray probes development. Gamma photons can be either directly detected via high atomic numbers semiconductors detectors or indirect detection, as scintillator crystal converts gamma photons into light photons. In all of them, the preamplifier is used as close as possible to the detector for obtaining a good energy resolution and due to the necessary small probe dimension, the preamplifier must have reduced size. The commercial preamplifiers are not small enough to be assembled inside the probe. It was developed a not usually preamplifier configuration for high-resolution spectroscopy energy, adequate in size to be set up in gamma-ray probes. This tension preamplifier can be split between the gamma-ray probe and the read out unit. Due to this configuration the effective size required inside the probe was reduced. The results and the probe assembling are showed in this work. (author)

  1. Hand-held medical robots.

    Science.gov (United States)

    Payne, Christopher J; Yang, Guang-Zhong

    2014-08-01

    Medical robots have evolved from autonomous systems to tele-operated platforms and mechanically-grounded, cooperatively-controlled robots. Whilst these approaches have seen both commercial and clinical success, uptake of these robots remains moderate because of their high cost, large physical footprint and long setup times. More recently, researchers have moved toward developing hand-held robots that are completely ungrounded and manipulated by surgeons in free space, in a similar manner to how conventional instruments are handled. These devices provide specific functions that assist the surgeon in accomplishing tasks that are otherwise challenging with manual manipulation. Hand-held robots have the advantages of being compact and easily integrated into the normal surgical workflow since there is typically little or no setup time. Hand-held devices can also have a significantly reduced cost to healthcare providers as they do not necessitate the complex, multi degree-of-freedom linkages that grounded robots require. However, the development of such devices is faced with many technical challenges, including miniaturization, cost and sterility, control stability, inertial and gravity compensation and robust instrument tracking. This review presents the emerging technical trends in hand-held medical robots and future development opportunities for promoting their wider clinical uptake.

  2. Gamma-ray imaging probes

    International Nuclear Information System (INIS)

    Wild, W.J.

    1988-01-01

    External nuclear medicine diagnostic imaging of early primary and metastatic lung cancer tumors is difficult due to the poor sensitivity and resolution of existing gamma cameras. Nonimaging counting detectors used for internal tumor detection give ambiguous results because distant background variations are difficult to discriminate from neighboring tumor sites. This suggests that an internal imaging nuclear medicine probe, particularly an esophageal probe, may be advantageously used to detect small tumors because of the ability to discriminate against background variations and the capability to get close to sites neighboring the esophagus. The design, theory of operation, preliminary bench tests, characterization of noise behavior and optimization of such an imaging probe is the central theme of this work

  3. Portable Hand-Held Electrochemical Sensor for the Transuranics

    Energy Technology Data Exchange (ETDEWEB)

    Dale D. Russell, William B. Knowlton, Ph.D.; Russel Hertzog, Ph.D

    2005-11-25

    sensitive detector for uranium. Millimeter scale electrodes, operated by a hand-held instrument assembled in this lab and operated in the voltammetric mode, were transported to the DOE-Nevada test site (Las Vegas, NV) where field detection and quantitation of plutonium, uranium, and a mixture of these two elements was also demonstrated. Several probe designs were prepared, built and tested including probes with movable protective windows. A miniature, battery powered potentiostat was designed, built and demonstrated for use in a hand-held field portable instrument. This work was performed largely by undergraduates who gained valuable research experience, and many of them have continued on to graduate schools. In addition, they all gained exposure to and appreciation for national security research, in particular non-proliferation research. Four graduate students participated and one earned the MS degree on this project.

  4. Clinical applications of gamma-detection probes - radioguided surgery

    International Nuclear Information System (INIS)

    Schneebaum, S.; Stadler, J.; Skornick, Y.

    1999-01-01

    Radioguided surgery (RGS) is a surgical technique that enables the surgeon to identify tissue ''marked'' by a radionuclide before surgery, based on the tissue characteristics, the radioactive tracer and its carrying molecule, or the affinity of both. Thus, yet another tool has been added to the inspection and palpation traditionally used by the surgeon. Current clinical applications of radioguided surgery are: radioimmunoguided surgery (RIGS) for colon cancer, sentinel-node mapping for malignant melanoma (which has become state-of-the-art), sentinel-node mapping for breast, vulvar and penile cancer, and detection of parathyroid adenoma and bone tumour (such as osteid osteoma). Although the same gamma-detecting probe (GDP) may be used for all these applications, the carrier substance and the radionuclide differ. MoAb and peptides are used for RIGS, sulphur colloid for sentinel-node mapping, iodine-125 for RIGS, technetium-99m for sentinel node, parathyroid and bone. The mode of injection also differs, but there are some common principles of gamma-guided surgery. RIGS enables the surgeon to corroborate tumour existence, find occult metastases, and assess the margins of resection; this may result in a change on the surgical plan. Sentinel lymph-node (SLN) scintigraphy for melanoma guides the surgeon to find the involved lymph nodes for lymph-node dissection. SLN for breast cancer is being investigated with promising results. This procedure has also changed the outlook of lymph-node pathology by giving the pathologist designated tissue samples for more comprehensive examination. Gamma-guided surgery will result in more accurate and less unnecessary surgery, better pathology and, hopefully, in better patient survival. (orig.)

  5. 30 CFR 56.12033 - Hand-held electric tools.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL....12033 Hand-held electric tools. Hand-held electric tools shall not be operated at high potential...

  6. Evaluation of a focussed protocol for hand-held echocardiography and computer-assisted auscultation in detecting latent rheumatic heart disease in scholars.

    Science.gov (United States)

    Zühlke, Liesl J; Engel, Mark E; Nkepu, Simpiwe; Mayosi, Bongani M

    2016-08-01

    Introduction Echocardiography is the diagnostic test of choice for latent rheumatic heart disease. The utility of echocardiography for large-scale screening is limited by high cost, complex diagnostic protocols, and time to acquire multiple images. We evaluated the performance of a brief hand-held echocardiography protocol and computer-assisted auscultation in detecting latent rheumatic heart disease with or without pathological murmur. A total of 27 asymptomatic patients with latent rheumatic heart disease based on the World Heart Federation criteria and 66 healthy controls were examined by standard cardiac auscultation to detect pathological murmur. Hand-held echocardiography using a focussed protocol that utilises one view - that is, the parasternal long-axis view - and one measurement - that is, mitral regurgitant jet - and a computer-assisted auscultation utilising an automated decision tool were performed on all patients. The sensitivity and specificity of computer-assisted auscultation in latent rheumatic heart disease were 4% (95% CI 1.0-20.4%) and 93.7% (95% CI 84.5-98.3%), respectively. The sensitivity and specificity of the focussed hand-held echocardiography protocol for definite rheumatic heart disease were 92.3% (95% CI 63.9-99.8%) and 100%, respectively. The test reliability of hand-held echocardiography was 98.7% for definite and 94.7% for borderline disease, and the adjusted diagnostic odds ratios were 1041 and 263.9 for definite and borderline disease, respectively. Computer-assisted auscultation has extremely low sensitivity but high specificity for pathological murmur in latent rheumatic heart disease. Focussed hand-held echocardiography has fair sensitivity but high specificity and diagnostic utility for definite or borderline rheumatic heart disease in asymptomatic patients.

  7. 30 CFR 57.12033 - Hand-held electric tools.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...

  8. Lymphoscintigraphy and intra-operative gamma probe in detection of sentinel lymph node for breast cancer surgery

    International Nuclear Information System (INIS)

    Le Ngoc Ha; Le Manh Ha; Bui Quang Bieu

    2011-01-01

    Sentinel lymph node biopsy (SLNB) has been emerged as a highly accurate method of axillary staging in management of breast cancer patients. Sentinel lymph node detection (SLND) by lymphoscintigraphy and intra-operative gamma probe for SLNB have been widely used in the world. Objectives: the purpose of our study was to evaluate the result of techniques using lymphoscintigraphy and intra-operative gamma probe for SLND in breast carcinoma patients. Materials and Methods: 102 patients with early breast carcinoma were enrolled in the study. Lymphoscintigraphy using Tc-99m-human serum albumin colloid, intra-operative gamma probe were undergone for localization and SLNB. Total axillary lymph node was dissected in breast cancer surgery. Results: The success rate of lymphoscintigraphy and SLND was 98.0% (100/102 patients), mean number of sentinel lymph node (SLN)/patient was 1.56 ± 0.79 (ranged 1 - 3), number of lymphatic vessel/SLN was 1.5 ± 0.69 (ranged 1 - 4) and mean time for SLND on lymphoscintigraphy was 4.21 ± 13.4 minutes (2 - 15 minutes). The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of radio-guided SLNB for axillary staging was 100%, 70.6%, 41.2%, 100% and 75.6 % respectively. Conclusions: radio-guided SLNB by lymphoscintigraphy and intra-operative gamma probe is feasible and reliable for axillary staging in early breast carcinoma patients. (author)

  9. Somatostatin receptor scintigraphy and intraoperative gamma probe detection in the localisation and treatment of pancreatic insulinoma

    International Nuclear Information System (INIS)

    Loh, Nelson K.; Macdonald, William B.; Dunne, Marina L.; Rao, Sudhakar

    2009-01-01

    Full text: Aims: We report a case of insulinoma that was successfully enucleated under radio-guidance after an initial unsuccessful laparotomy. This case highlights the utility of Somatostatin Receptor Scintigraphy (SRS) and gamma probe in the localisation and treatment of neuroendocrine tumours. Methods: The patient presented with recurrent hypoglycaemia. An abdominal CT scan identified a lesion in the uncinate process of the pancreas, however, laparotomy with use of intraoperative ultrasound failed to localise the lesion. SRS with SPECTICT was then requested by the surgical team with a view to radio-guided surgery. Results: SRS demonstrated an octreotide-avid tumour in the posterior uncinate process of the pancreas, and confirmed suitability for radio-guided surgery. At re-exploration, the surgeon was again unable to palpate the lesion or localise it with intraoperative ultrasound, however, the lesion was successfully detected and removed with the use of a gamma probe. A postoperative SRS confirmed complete excision and histopathology was diagnostic of insulinoma. Conclusion: This case highlights the utility of SRS in the intraoperative localisation and surgical excision of neuroendocrine tumours. The lesion was unable to be localised clinically or with intraoperative ultrasound but was successfully detected with scintigraphic techniques. The surgical team acknowledge that the use of a gamma probe enabled enucleation of the insulinoma, which obviated the need for an invasive Whipple's procedure.

  10. Development of dual sensor hand-held detector

    Science.gov (United States)

    Sezgin, Mehmet

    2010-04-01

    In this paper hand-held dual sensor detector development requirements are considered dedicated to buried object detection. Design characteristics of such a system are categorized and listed. Hardware and software structures, ergonomics, user interface, environmental and EMC/EMI tests to be applied and performance test issues are studied. Main properties of the developed system (SEZER) are presented, which contains Metal Detector (MD) and Ground Penetrating Radar (GPR). The realized system has ergonomic structure and can detect both metallic and non-metallic buried objects. Moreover classification of target is possible if it was defined to the signal processing software in learning phase.

  11. Handheld optical coherence tomography-reflectance confocal microscopy probe for detection of basal cell carcinoma and delineation of margins

    Science.gov (United States)

    Iftimia, Nicusor; Yélamos, Oriol; Chen, Chih-Shan J.; Maguluri, Gopi; Cordova, Miguel A.; Sahu, Aditi; Park, Jesung; Fox, William; Alessi-Fox, Christi; Rajadhyaksha, Milind

    2017-07-01

    We present a hand-held implementation and preliminary evaluation of a combined optical coherence tomography (OCT) and reflectance confocal microscopy (RCM) probe for detecting and delineating the margins of basal cell carcinomas (BCCs) in human skin in vivo. A standard OCT approach (spectrometer-based) with a central wavelength of 1310 nm and 0.11 numerical aperture (NA) was combined with a standard RCM approach (830-nm wavelength and 0.9 NA) into a common path hand-held probe. Cross-sectional OCT images and enface RCM images are simultaneously displayed, allowing for three-dimensional microscopic assessment of tumor morphology in real time. Depending on the subtype and depth of the BCC tumor and surrounding skin conditions, OCT and RCM imaging are able to complement each other, the strengths of each helping overcome the limitations of the other. Four representative cases are summarized, out of the 15 investigated in a preliminary pilot study, demonstrating how OCT and RCM imaging may be synergistically combined to more accurately detect BCCs and more completely delineate margins. Our preliminary results highlight the potential benefits of combining the two technologies within a single probe to potentially guide diagnosis as well as treatment of BCCs.

  12. Implementation of synthetic aperture imaging on a hand-held device

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian; Kjeldsen, Thomas; Larsen, Lee

    2014-01-01

    -held devices all with different chipsets and a BK Medical UltraView 800 ultrasound scanner emulating a wireless probe. The wireless transmission is benchmarked using an imaging setup consisting of 269 scan lines x 1472 complex samples (1.58 MB pr. frame, 16 frames per second). The measured data throughput...... reached an average of 28.8 MB/s using a LG G2 mobile device, which is more than the required data throughput of 25.3 MB/s. Benchmarking the processing performance for B-mode imaging showed a total processing time of 18.9 ms (53 frames/s), which is less than the acquisition time (62.5 ms).......This paper presents several implementations of Syn- thetic Aperture Sequential Beamforming (SASB) on commer- cially available hand-held devices. The implementations include real-time wireless reception of ultrasound radio frequency sig- nals and GPU processing for B-mode imaging. The proposed...

  13. PET Probe-Guided Surgery in Patients with Breast Cancer: Proposal for a Methodological Approach

    Science.gov (United States)

    ORSARIA, PAOLO; CHIARAVALLOTI, AGOSTINO; FIORENTINI, ALESSANDRO; PISTOLESE, CHIARA; VANNI, GIANLUCA; VITTORIA GRANAI, ALESSANDRA; VARVARAS, DIMITRIOS; DANIELI, ROBERTA; SCHILLACI, ORAZIO; PETRELLA, GIUSEPPE; CLAUDIO BUONOMO, ORESTE

    2017-01-01

    Background: Although it is valuable for detecting distant metastases, identifying recurrence, and evaluating responses to chemotherapy, the role of 18F-fluorodeoxyglucose positron-emission tomography/computed tomography (18F-FDG PET/CT) in assessing locoregional nodal status for initial staging of breast cancer has not yet been well-defined in clinical practice. In the current report, we describe a new PET probe-based clinical approach, with evaluation of the technical performance of a handheld high-energy gamma probe for intraoperative localization of breast carcinomas, and evaluation of lymph node metastases during radio-guided oncological surgery. Patients and Methods: Three patients underwent a PET/CT scan immediately prior to surgery following the standard clinical protocol. Intraoperatively, tumors were localized and resected with the assistance of a hand-held gamma probe. PET-guided assessment of the presence or absence of regional nodal spread of malignancy was compared with the reference standard of histopathological examination. Results: In all three cases, perioperative 18F-FDG PET/CT imaging and intraoperative gamma probe detection verified complete resection of the hypermetabolic lesions and demonstrated no additional suspicious occult disease. Conclusion: This innovative approach demonstrates great promise for providing real-time access to metabolic and morphological tumor information that may lead to an optimal disease-tailored approach. In carefully selected indications, a PET probe can be a useful adjunct in surgical practice, but further trials with a larger number of patients need to be performed to verify these findings. PMID:28064227

  14. A hand-held robotic device for peripheral intravenous catheterization.

    Science.gov (United States)

    Cheng, Zhuoqi; Davies, Brian L; Caldwell, Darwin G; Barresi, Giacinto; Xu, Qinqi; Mattos, Leonardo S

    2017-12-01

    Intravenous catheterization is frequently required for numerous medical treatments. However, this process is characterized by a high failure rate, especially when performed on difficult patients such as newborns and infants. Very young patients have small veins, and that increases the chances of accidentally puncturing the catheterization needle directly through them. In this article, we present the design, development and experimental evaluation of a novel hand-held robotic device for improving the process of peripheral intravenous catheterization by facilitating the needle insertion procedure. To our knowledge, this design is the first hand-held robotic device for assisting in the catheterization insertion task. Compared to the other available technologies, it has several unique advantages such as being compact, low-cost and able to reliably detect venipuncture. The system is equipped with an electrical impedance sensor at the tip of the catheterization needle, which provides real-time measurements used to supervise and control the catheter insertion process. This allows the robotic system to precisely position the needle within the lumen of the target vein, leading to enhanced catheterization success rate. Experiments conducted to evaluate the device demonstrated that it is also effective to deskill the task. Naïve subjects achieved an average catheterization success rate of 88% on a 1.5 mm phantom vessel with the robotic device versus 12% with the traditional unassisted system. The results of this work prove the feasibility of a hand-held assistive robotic device for intravenous catheterization and show that such device has the potential to greatly improve the success rate of these difficult operations.

  15. A very accurate method for sentinel lymph node investigation: Gamma detecting probe associated with SPECT examination for depth

    International Nuclear Information System (INIS)

    Ascoli, G.; Cinti, P.; Nonni, M.; Rossi, B.

    2002-01-01

    Aim: aim of this study is to magnify the lymphoscintigraphy examination by gamma probe with SPECT acquisition for very accurate detection of depth of axilla node in patients affected by melanoma. Methods: according to physiological peculiarities the lymphatic system plays a very important role and represents the most important barrier to neoplastic cells spreading. The 'sentinel node' is the first lymph node draining the affected area. The tendency for surgery is a 'preventive' axillary dissection, even in presence of a clinically negative examination. In fact a high percentage of clinically negative lymph node shows a positive histology (presence of metastatic cells). The nuclear medicine method for researching 'sentinel node' is represented by a regional lymphoscintigraphy with normal gamma camera with a large field of view followed by examination with gamma detecting probe and, in following day, controlled in operating room to confirm the presence of the node early identified. We have completed this protocol with SPECT examination of affected axilla by use of injected laboratory capillary around axilla to perform an exact investigation of node depth. Discussion: Our experience in 150 cases in 18 months shows 100% of axilla 'sentinel node' detection, 25 cases with positive histologic examination and subsequently axillary dissection. Conclusions: In conclusion the scintigraphic examination with lymphoscintigraphy represents a good tool for management of patient with melanoma and the use of ''targeting' with collimated SPECT represent a very aid for the surgeon in reduction time for detection and dissection of lymph node, with high reduction of anesthesia duration

  16. Quality control devices for intraoperative gamma probes: physical, technical and radiation protection aspects

    International Nuclear Information System (INIS)

    Varela, C.; Diaz, M.; Salvador, F.J.; Hernandez, M.; Jimenez, P.

    2008-01-01

    Now a day, radio guided surgery -a novelty in Nuclear Medicine- is increasingly used. The clinical efficiency of these procedures requires the existence of well-trained professionals and implementation of quality assurance programs. It is essential for achieving the main objective, which is an effective and safe surgical procedure, a reliable performance of the detection device. Probes' parameters must remain within the acceptance limits, so they should be checked periodically. NEMA Standards Publication NU 3-2004 'Performance Measurement and Quality Control Guidelines for Non-Imaging Intraoperative Gamma Probes' recommends 13 tests; although only 3 of them -sensibility in air, visual inspection and power source check- are considered as steadiness tests. Space resolution in a scatter medium is also a test that needs to be carried out. These tests are considerably complex since open radioactive sources are used into a liquid medium in most of the procedures. The immersion of the probe and of the radioactive sources in each case represents both risks of radioactive contamination, and of damages to the equipment. On the other hand, tests in air demand a good reproducibility. Since they are recommended be carried out before any surgery procedure, they also should be easy and quick. This paper presents 3 devices with its accessories for acceptance and quality control tests of intraoperative gamma probes. They were designed and built taking into consideration important aspects of radiological protection to handle the calibration sources and probes, both in air and into a scatter medium. These devices are designed to fit any kind of probe. Regulatory bodies as part of their instrument audits can also use them. (author)

  17. Driver hand-held cellular phone use: a four-year analysis.

    Science.gov (United States)

    Eby, David W; Vivoda, Jonathon M; St Louis, Renée M

    2006-01-01

    The use of hand-held cellular (mobile) phones while driving has stirred more debate, passion, and research than perhaps any other traffic safety issue in the past several years. There is ample research showing that the use of either hand-held or hands-free cellular phones can lead to unsafe driving patterns. Whether or not these performance deficits increase the risk of crash is difficult to establish, but recent studies are beginning to suggest that cellular phone use elevates crash risk. The purpose of this study was to assess changes in the rate of hand-held cellular phone use by motor-vehicle drivers on a statewide level in Michigan. This study presents the results of 13 statewide surveys of cellular phone use over a 4-year period. Hand-held cellular phone use data were collected through direct observation while vehicles were stopped at intersections and freeway exit ramps. Data were weighted to be representative of all drivers traveling during daylight hours in Michigan. The study found that driver hand-held cellular phone use has more than doubled between 2001 and 2005, from 2.7% to 5.8%. This change represents an average increase of 0.78 percentage points per year. The 5.8% use rate observed in 2005 means that at any given daylight hour, around 36,550 drivers were conversing on cellular phones while driving on Michigan roadways. The trend line fitted to these data predicts that by the year 2010, driver hand-held cellular phone use will be around 8.6%, or 55,000 drivers at any given daylight hour. These results make it clear that cellular phone use while driving will continue to be an important traffic safety issue, and highlight the importance of continued attempts to generate new ways of alleviating this potential hazard.

  18. Gamma-Ray Pulsar Light Curves as Probes of Magnetospheric Structure

    Science.gov (United States)

    Harding, A. K.

    2016-01-01

    The large number of gamma-ray pulsars discovered by the Fermi Gamma-Ray Space Telescope since its launch in 2008 dwarfs the handful that were previously known. The variety of observed light curves makes possible a tomography of both the ensemble-averaged field structure and the high-energy emission regions of a pulsar magnetosphere. Fitting the gamma-ray pulsar light curves with model magnetospheres and emission models has revealed that most of the high-energy emission, and the particles acceleration, takes place near or beyond the light cylinder, near the current sheet. As pulsar magnetosphere models become more sophisticated, it is possible to probe magnetic field structure and emission that are self-consistently determined. Light curve modeling will continue to be a powerful tool for constraining the pulsar magnetosphere physics.

  19. Hand-held, mechanically cooled, radiation detection system for gamma-ray spectroscopy

    Science.gov (United States)

    Burks, Morgan Thomas; Eckels, Joel Del

    2010-06-08

    In one embodiment, a radiation detection system is provided including a radiation detector and a first enclosure encapsulating the radiation detector, the first enclosure including a low-emissivity infra-red (IR) reflective coating used to thermally isolate the radiation detector. Additionally, a second enclosure encapsulating the first enclosure is included, the first enclosure being suspension mounted to the second enclosure. Further, a cooler capable of cooling the radiation detector is included. Still yet, a first cooling interface positioned on the second enclosure is included for coupling the cooler and the first enclosure. Furthermore, a second cooling interface positioned on the second enclosure and capable of coupling the first enclosure to a cooler separate from the radiation detection system is included. Other embodiments are also presented.

  20. Gamma-Ray Imaging Probes.

    Science.gov (United States)

    Wild, Walter James

    1988-12-01

    External nuclear medicine diagnostic imaging of early primary and metastatic lung cancer tumors is difficult due to the poor sensitivity and resolution of existing gamma cameras. Nonimaging counting detectors used for internal tumor detection give ambiguous results because distant background variations are difficult to discriminate from neighboring tumor sites. This suggests that an internal imaging nuclear medicine probe, particularly an esophageal probe, may be advantageously used to detect small tumors because of the ability to discriminate against background variations and the capability to get close to sites neighboring the esophagus. The design, theory of operation, preliminary bench tests, characterization of noise behavior and optimization of such an imaging probe is the central theme of this work. The central concept lies in the representation of the aperture shell by a sequence of binary digits. This, coupled with the mode of operation which is data encoding within an axial slice of space, leads to the fundamental imaging equation in which the coding operation is conveniently described by a circulant matrix operator. The coding/decoding process is a classic coded-aperture problem, and various estimators to achieve decoding are discussed. Some estimators require a priori information about the object (or object class) being imaged; the only unbiased estimator that does not impose this requirement is the simple inverse-matrix operator. The effects of noise on the estimate (or reconstruction) is discussed for general noise models and various codes/decoding operators. The choice of an optimal aperture for detector count times of clinical relevance is examined using a statistical class-separability formalism.

  1. A new method for intraoperative localization of epilepsy focus by means of a gamma probe

    International Nuclear Information System (INIS)

    Carneiro Filho, Omar; Vilela Filho, Osvaldo; Ragazzo, Paulo Cesar; Fonseca, Lea Mirian Barbosa da

    2014-01-01

    Objective: to evaluate the utility of a new multimodal image-guided intervention technique to detect epileptogenic areas with a gamma probe as compared with intraoperative electrocorticography. Materials and methods: two symptomatic patients with refractory epilepsy underwent magnetic resonance imaging, videoelectroencephalography, brain SPECT scan, neuropsychological evaluation and were submitted to gamma probe-assisted surgery. Results: in patient 1, maximum radioactive count was initially observed on the temporal gyrus at about 3.5 cm posteriorly to the tip of the left temporal lobe. After corticotomy, the gamma probe indicated maximum count at the head of the hippocampus, in agreement with the findings of intraoperative electrocorticography. In patient 2, maximum count was observed in the occipital region at the transition between the temporal and parietal lobes (right hemisphere). During the surgery, the area of epileptogenic activity mapped at electrocorticography was also delimited, demarcated, and compared with the gamma probe findings. After lesionectomy, new radioactive counts were performed both in the patients and on the surgical specimens (ex-vivo). Conclusion: the comparison between intraoperative electrocorticography and gamma probe-assisted surgery showed similarity of both methods. The advantages of gamma probe include: noninvasiveness, low cost and capacity to demonstrate decrease in the radioactive activity at the site of excision after lesionectomy. (author)

  2. 75 FR 27504 - Substantial Product Hazard List: Hand-Held Hair Dryers

    Science.gov (United States)

    2010-05-17

    ... immersion during their use. Section 15(a) of the CPSA defines ``substantial product hazard'' to include, a....'' Hand-held hair dryers routinely contain open-coil heating elements that are, in essence, uninsulated..., bathtub, or lavatory). The proposed rule would define ``hand-held hair dryer'' as ``an electrical...

  3. Hand-held spectrophotometer design for textile fabrics

    Science.gov (United States)

    Böcekçi, Veysel Gökhan; Yıldız, Kazım

    2017-09-01

    In this study, a hand-held spectrophotometer was designed by taking advantage of the developments in modern optoelectronic technology. Spectrophotometer devices are used to determine the color information from the optic properties of the materials. As an alternative to a desktop spectrophotometer device we have implemented, it is the first prototype, low cost and portable. The prototype model designed for the textile industry can detect the color tone of any fabric. The prototype model consists of optic sensor, processor, display floors. According to the color applied on the optic sensor, it produces special frequency information on its output at that color value. In Arduino type processor, the frequency information is evaluated by the program we have written and the color tone information between 0-255 ton is decided and displayed on the screen.

  4. Integrated optical detection of autonomous capillary microfluidic immunoassays:a hand-held point-of-care prototype.

    Science.gov (United States)

    Novo, P; Chu, V; Conde, J P

    2014-07-15

    The miniaturization of biosensors using microfluidics has potential in enabling the development of point-of-care devices, with the added advantages of reduced time and cost of analysis with limits-of-detection comparable to those obtained through traditional laboratory techniques. Interfacing microfluidic devices with the external world can be difficult especially in aspects involving fluid handling and the need for simple sample insertion that avoids special equipment or trained personnel. In this work we present a point-of-care prototype system by integrating capillary microfluidics with a microfabricated photodiode array and electronic instrumentation into a hand-held unit. The capillary microfluidic device is capable of autonomous and sequential fluid flow, including control of the average fluid velocity at any given point of the analysis. To demonstrate the functionality of the prototype, a model chemiluminescence ELISA was performed. The performance of the integrated optical detection in the point-of-care prototype is equal to that obtained with traditional bench-top instrumentation. The photodiode signals were acquired, displayed and processed by a simple graphical user interface using a computer connected to the microcontroller through USB. The prototype performed integrated chemiluminescence ELISA detection in about 15 min with a limit-of-detection of ≈2 nM with an antibody-antigen affinity constant of ≈2×10(7) M(-1). Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Attentionally splitting the mass distribution of hand-held rods.

    Science.gov (United States)

    Burton, G; Turvey, M T

    1991-08-01

    Two experiments on the length-perception capabilities of effortful or dynamic touch differed only in terms of what the subject intended to perceive, while experimental conditions and apparatus were held constant. In each trial, a visually occluded rod was held as still as possible by the subject at an intermediate position. For two thirds of the trials, a weight was attached to the rod above or below the hand. In Experiment 1, in which the subject's task was to perceive the distance reachable with the portion of the rod forward of the hand, perceived extent was a function of the first moment of the mass distribution associated with the forward portion of the rod, and indifferent to the first moment of the entire rod. In Experiment 2, in which the task was to perceive the distance reachable with the entire rod if it was held at an end, the pattern of results was reversed. These results indicate the capability of selective sensitivity to different aspects of a hand-held object's mass distribution, without the possibility of differential exploration specific to these two tasks. Results are discussed in relation to possible roles of differential information, intention, and self-organization in the explanations of selective perceptual abilities.

  6. Optimization of in situ prompt gamma-ray analysis using a HPGe-252Cf probe

    International Nuclear Information System (INIS)

    Chien Chung; Jiunnhsing Chao

    1991-01-01

    Application of in situ measurements by the neutron-induced prompt gamma-ray activation analysis (PGAA) technique to geochemical analysis and mineral survey have been investigated. An in situ survey of water pollutants by PGAA techniques was first proposed in the authors' previous study, where a 2.7-μg 252 Cf neutron source used in connection with a gamma-ray detecting system to determine water pollutants was described. In this paper the authors describe a modified detection probe designed and constructed to look for the optimum conditions of various-intensity 252 Cf neutron sources in measurement of some elements in lake water. Detecting efficiencies at high-energy regions and detection limits for elements commonly found in polluted lakes were evaluated and predicted to investigate the potential application of the probe for in situ measurements

  7. Probing Intrinsic Properties of Short Gamma-Ray Bursts with Gravitational Waves.

    Science.gov (United States)

    Fan, Xilong; Messenger, Christopher; Heng, Ik Siong

    2017-11-03

    Progenitors of short gamma-ray bursts are thought to be neutron stars coalescing with their companion black hole or neutron star, which are one of the main gravitational wave sources. We have devised a Bayesian framework for combining gamma-ray burst and gravitational wave information that allows us to probe short gamma-ray burst luminosities. We show that combined short gamma-ray burst and gravitational wave observations not only improve progenitor distance and inclination angle estimates, they also allow the isotropic luminosities of short gamma-ray bursts to be determined without the need for host galaxy or light-curve information. We characterize our approach by simulating 1000 joint short gamma-ray burst and gravitational wave detections by Advanced LIGO and Advanced Virgo. We show that ∼90% of the simulations have uncertainties on short gamma-ray burst isotropic luminosity estimates that are within a factor of two of the ideal scenario, where the distance is known exactly. Therefore, isotropic luminosities can be confidently determined for short gamma-ray bursts observed jointly with gravitational waves detected by Advanced LIGO and Advanced Virgo. Planned enhancements to Advanced LIGO will extend its range and likely produce several joint detections of short gamma-ray bursts and gravitational waves. Third-generation gravitational wave detectors will allow for isotropic luminosity estimates for the majority of the short gamma-ray burst population within a redshift of z∼1.

  8. Practical use of chemical probes for reactive oxygen species produced in biological systems by {gamma}-irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Hee; Moon, Yu Ran; Chung, Byung Yeoup; Kim, Jae-Sung [Radiation Research Division for Bio-technology, Korea Atomic Energy Research Institute, 1266 Sinjeong-dong, Jeongeup-si, Jeollabuk-do 580-185 (Korea, Republic of); Lee, Kang-Soo [Crop Production and Technology Major, Chonbuk National University, Jeonju 561-756 (Korea, Republic of); Cho, Jae-Young [Bio-environmental Science Major, Chonbuk National University, Jeonju 561-756 (Korea, Republic of); Kim, Jin-Hong [Radiation Research Division for Bio-technology, Korea Atomic Energy Research Institute, 1266 Sinjeong-dong, Jeongeup-si, Jeollabuk-do 580-185 (Korea, Republic of)], E-mail: jhongkim@kaeri.re.kr

    2009-05-15

    Application of chemical probes, for detection of reactive oxygen species (ROS), was tested during {gamma}-irradiation. The ethanol/{alpha}-(4-pyridyl-1-oxide)-N-tert-butylnitrone (4-POBN) and 3,3'-diaminobenzidine (DAB) were structurally stable enough to detect {sup {center_dot}}OH and H{sub 2}O{sub 2}, increasingly generated by {gamma}-irradiation up to 1000 Gy. Interestingly, the production rate of H{sub 2}O{sub 2}, but not {sup {center_dot}}OH, during {gamma}-irradiation, was significantly different between in vitro systems of lettuce and spinach. These results suggest that 4-POBN and DAB could be utilized as a semi-quantitative probe to quantify {sup {center_dot}}OH and H{sub 2}O{sub 2}, produced by {gamma}-irradiation up to 1000 Gy.

  9. Ultrasonography with a hand-held device for the diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Kameda, Toru; Takahashi, Isao

    2009-01-01

    The purpose of this study was to evaluate the accuracy of ultrasonography (US) with a hand-held device for the diagnosis of acute appendicitis in the emergency room. US with a hand-held device was performed by the first author in 33 patients suspected of having appendicitis in the emergency room. From these 33 patients, 24 who subsequently underwent computed tomography (CT) or surgery were included in this study. The accuracy of US with the hand-held device for the diagnosis of acute appendicitis was evaluated based on the findings of CT or surgery. CT and surgery were performed in 22 and 12 patients, respectively. Final diagnoses were acute appendicitis (n=18), terminal ileitis (n=2), pelvic inflammatory disease (n=2), diverticulitis (n=1), and ureterolithiasis (n=1). The US yielded a sensitivity of 78% and a positive predictive value of 100%. The shortest distance between the abdominal wall and the appendix measured on CT was less than 40 mm in 11 patients. In ten (91%) of the 11 patients US with the hand-held device showed the swollen appendix. US with a hand-held device is potentially useful in the positive identification of acute appendicitis, but further investigation is needed to prove its utility in the routine diagnosis of acute appendicitis. (author)

  10. Intraoperative detection of 18F-FDG-avid tissue sites using the increased probe counting efficiency of the K-alpha probe design and variance-based statistical analysis with the three-sigma criteria

    International Nuclear Information System (INIS)

    Povoski, Stephen P; Chapman, Gregg J; Murrey, Douglas A; Lee, Robert; Martin, Edward W; Hall, Nathan C

    2013-01-01

    Intraoperative detection of 18 F-FDG-avid tissue sites during 18 F-FDG-directed surgery can be very challenging when utilizing gamma detection probes that rely on a fixed target-to-background (T/B) ratio (ratiometric threshold) for determination of probe positivity. The purpose of our study was to evaluate the counting efficiency and the success rate of in situ intraoperative detection of 18 F-FDG-avid tissue sites (using the three-sigma statistical threshold criteria method and the ratiometric threshold criteria method) for three different gamma detection probe systems. Of 58 patients undergoing 18 F-FDG-directed surgery for known or suspected malignancy using gamma detection probes, we identified nine 18 F-FDG-avid tissue sites (from amongst seven patients) that were seen on same-day preoperative diagnostic PET/CT imaging, and for which each 18 F-FDG-avid tissue site underwent attempted in situ intraoperative detection concurrently using three gamma detection probe systems (K-alpha probe, and two commercially-available PET-probe systems), and then were subsequently surgical excised. The mean relative probe counting efficiency ratio was 6.9 (± 4.4, range 2.2–15.4) for the K-alpha probe, as compared to 1.5 (± 0.3, range 1.0–2.1) and 1.0 (± 0, range 1.0–1.0), respectively, for two commercially-available PET-probe systems (P < 0.001). Successful in situ intraoperative detection of 18 F-FDG-avid tissue sites was more frequently accomplished with each of the three gamma detection probes tested by using the three-sigma statistical threshold criteria method than by using the ratiometric threshold criteria method, specifically with the three-sigma statistical threshold criteria method being significantly better than the ratiometric threshold criteria method for determining probe positivity for the K-alpha probe (P = 0.05). Our results suggest that the improved probe counting efficiency of the K-alpha probe design used in conjunction with the three

  11. The lymphoscintigraphy and intraoperative gamma detection of sentinel lymph node in oral cavity carcinoma

    International Nuclear Information System (INIS)

    Zhao Xinming; Zhang Jingmian; Wang Jianfang; Li Dezhi; Sun Li; Dai Chunnuan; He Yang

    2006-01-01

    Objective: To evaluate the role of lymphoscintigraphy and intraoperative gamma probe detection of sentinel lymph node (SLN) in oral cavity carcinoma. Methods: 99 Tc m labeled dextran (DX) was injected submucously at the center of oral cavity carcinoma before operation. The SLN identified by lymphoscintigraphy and intraoperative gamma counter probe were dissected out from the exited tissue. All sentinel and other lymph nodes were sent for pathological examination. Results: In all 33 cases, SLN and other lymph nodes were clear identified by lymphoscintigraphy. Forty-three SLNs were seen, among them 1 in 25 cases, 2 in 6 cases and 3 in 2 cases. Metastases were detected by biopsy in SLN in 9 cases, however, 11 cases showed positive neck lymph node metastases. The sensitivity of SLN gamma detection was 100% and in biopsy sensitivity was 81.82%, accuracy was 93.94%, false positive rate was 0, and false negative rate was 18.18%. Conclusions: Intraoperative gamma probe detection is the reliable approach to identify SLN in oral cavity carcinoma. Lymphoscintigraphy is the base of localization for oral cavity carcinoma. (authors)

  12. Adaptive RF front-ends for hand-held applications

    CERN Document Server

    van Bezooijen, Andre; van Roermund, Arthur

    2010-01-01

    The RF front-end - antenna combination is a vital part of a mobile phone because its performance is very relevant to the link quality between hand-set and cellular network base-stations. The RF front-end performance suffers from changes in operating environment, like hand-effects, that are often unpredictable. ""Adaptive RF Front-Ends for Hand-Held Applications"" presents an analysis on the impact of fluctuating environmental parameters. In order to overcome undesired behavior two different adaptive control methods are treated that make RF frond-ends more resilient: adaptive impedance control,

  13. Intraoperative detection of ¹⁸F-FDG-avid tissue sites using the increased probe counting efficiency of the K-alpha probe design and variance-based statistical analysis with the three-sigma criteria.

    Science.gov (United States)

    Povoski, Stephen P; Chapman, Gregg J; Murrey, Douglas A; Lee, Robert; Martin, Edward W; Hall, Nathan C

    2013-03-04

    Intraoperative detection of (18)F-FDG-avid tissue sites during 18F-FDG-directed surgery can be very challenging when utilizing gamma detection probes that rely on a fixed target-to-background (T/B) ratio (ratiometric threshold) for determination of probe positivity. The purpose of our study was to evaluate the counting efficiency and the success rate of in situ intraoperative detection of (18)F-FDG-avid tissue sites (using the three-sigma statistical threshold criteria method and the ratiometric threshold criteria method) for three different gamma detection probe systems. Of 58 patients undergoing (18)F-FDG-directed surgery for known or suspected malignancy using gamma detection probes, we identified nine (18)F-FDG-avid tissue sites (from amongst seven patients) that were seen on same-day preoperative diagnostic PET/CT imaging, and for which each (18)F-FDG-avid tissue site underwent attempted in situ intraoperative detection concurrently using three gamma detection probe systems (K-alpha probe, and two commercially-available PET-probe systems), and then were subsequently surgical excised. The mean relative probe counting efficiency ratio was 6.9 (± 4.4, range 2.2-15.4) for the K-alpha probe, as compared to 1.5 (± 0.3, range 1.0-2.1) and 1.0 (± 0, range 1.0-1.0), respectively, for two commercially-available PET-probe systems (P < 0.001). Successful in situ intraoperative detection of 18F-FDG-avid tissue sites was more frequently accomplished with each of the three gamma detection probes tested by using the three-sigma statistical threshold criteria method than by using the ratiometric threshold criteria method, specifically with the three-sigma statistical threshold criteria method being significantly better than the ratiometric threshold criteria method for determining probe positivity for the K-alpha probe (P = 0.05). Our results suggest that the improved probe counting efficiency of the K-alpha probe design used in conjunction with the three-sigma statistical

  14. Epilepsy Forewarning Using A Hand-Held Device

    Energy Technology Data Exchange (ETDEWEB)

    Hively, LM

    2005-02-21

    Over the last decade, ORNL has developed and patented a novel approach for forewarning of a large variety of machine and biomedical events. The present implementation uses desktop computers to analyze archival data. This report describes the next logical step in this effort, namely use of a hand-held device for the analysis.

  15. Standard guide to In-Plant performance evaluation of Hand-Held SNM monitors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This guide is one of a series on the application and evaluation of special nuclear material (SNM) monitors. Other guides in the series are listed in Section 2, and the relationship of in-plant performance evaluation to other procedures described in the series is illustrated in Fig. 1. Hand-held SNM monitors are described in of Guide C1112, and performance criteria illustrating their capabilities can be found in Appendix X1. 1.2 The purpose of this guide to in-plant performance evaluation is to provide a comparatively rapid procedure to verify that a hand-held SNM monitor performs as expected for detecting SNM or alternative test sources or to disclose the need for repair. The procedure can be used as a routine operational evaluation or it can be used to verify performance after a monitor is calibrated. 1.3 In-plant performance evaluations are more comprehensive than daily functional tests. They take place less often, at intervals ranging from weekly to once every three months, and derive their result fr...

  16. Leakage and scattered radiation from hand-held dental x-ray unit

    International Nuclear Information System (INIS)

    Kim, Eun Kyung

    2007-01-01

    To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR ΙΙΙ was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of hand-held dental X-ray unit were 70 kVp, 3 mA , 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. The mean dose at the hand level when human skull DXTTR ΙΙΙ was exposed with portable X-ray unit 6.39 μGy, and the mean dose with fixed X-ray unit 3.03 μGy (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was 2.97 μGy and with fixed X-ray unit the mean dose was 0.68 μGy (p<0.01). The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography

  17. Leakage and scattered radiation from hand-held dental x-ray unit

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Kyung [Dankook Univ. School of Dentistry, Seoul (Korea, Republic of)

    2007-06-15

    To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR {iota}{iota}{iota} was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of hand-held dental X-ray unit were 70 kVp, 3 mA , 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. The mean dose at the hand level when human skull DXTTR {iota}{iota}{iota} was exposed with portable X-ray unit 6.39 {mu}Gy, and the mean dose with fixed X-ray unit 3.03 {mu}Gy (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was 2.97 {mu}Gy and with fixed X-ray unit the mean dose was 0.68 {mu}Gy (p<0.01). The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography.

  18. Plans for Hand-Held/Portable Oil Assessment Devices

    National Research Council Canada - National Science Library

    Urbansky, Edward

    2005-01-01

    At the request of the U.S. Army Oil Analysis Program, the JOAP TSC conducted a market study, assembled a plan of action, and prepared a worksheet for the evaluation of portable or hand-held oil assessment devices...

  19. Use of gamma probe in 131I thyroid uptake studies

    International Nuclear Information System (INIS)

    Sarmento, Andrea Gondim Leitao

    2002-11-01

    Evaluation of thyroid uptake by administration of radioactive iodine is a well-defined procedure to assess patient thyroid function. In general, nuclear medicine institutions use gamma cameras coupled to pinhole collimators to perform uptake studies. With the growing use of intraoperative gamma probes in the radioguided surgical techniques, several institutions are purchasing this new and portable equipment, which can technically be also employed to assess patient's thyroid function, permitting further other applications of gamma cameras. The aim of the study was to compare thyroid uptake trails carried out with both gamma camera and intraoperative gamma probe, in order to evaluate the possible use of gamma probe for this purpose. At first a preliminary study of feasibility was carried out using a neck phantom to verify equipment efficiency with known activities of 131 I. Henceforth, work data from 12 patients undergone studies of thyroid uptakes were evaluated, 24 hours after oral administration of 370 kBq of 131 I. The maximum difference observed between the values obtained with both equipment was 60%, which demonstrated the feasibility of the proposed protocol and made clear that gamma probe can be useful for thyroid uptake studies. (author)

  20. An Intelligent Hand-Held Microsurgical Instrument for Improved Accuracy

    National Research Council Canada - National Science Library

    Ang, Wei

    2001-01-01

    This paper presents the development and initial experimental results of the first prototype of Micron, an active hand-held instrument to sense and compensate physiological tremor and other unwanted...

  1. Position statement on use of hand-held portable dental X-ray equipment

    International Nuclear Information System (INIS)

    2014-06-01

    The position statement focuses on justification in the medical field, in particular on the use of hand-held portable dental x-ray equipment. It supplements another HERCA position paper, providing a general overview of the use of all hand-held portable X-ray equipment. Key Messages: - HERCA finds that the use of hand-held portable X-ray devices should be discouraged except in special circumstances. - As a general rule, these devices should only be used in scenarios where an intraoral radiograph is deemed necessary for a patient and the use of a fixed or semi-mobile x-ray unit is impractical, e.g.: - nursing homes, residential care facilities or homes for persons with disabilities; - forensic odontology, - military operations abroad without dental facilities

  2. Algorithms for a hand-held miniature x-ray fluorescence analytical instrument

    International Nuclear Information System (INIS)

    Elam, W.T.; Newman, D.; Ziemba, F.

    1998-01-01

    The purpose of this joint program was to provide technical assistance with the development of a Miniature X-ray Fluorescence (XRF) Analytical Instrument. This new XRF instrument is designed to overcome the weaknesses of spectrometers commercially available at the present time. Currently available XRF spectrometers (for a complete list see reference 1) convert spectral information to sample composition using the influence coefficients technique or the fundamental parameters method. They require either a standard sample with composition relatively close to the unknown or a detailed knowledge of the sample matrix. They also require a highly-trained operator and the results often depend on the capabilities of the operator. In addition, almost all existing field-portable, hand-held instruments use radioactive sources for excitation. Regulatory limits on such sources restrict them such that they can only provide relatively weak excitation. This limits all current hand-held XRF instruments to poor detection limits and/or long data collection times, in addition to the licensing requirements and disposal problems for radioactive sources. The new XRF instrument was developed jointly by Quantrad Sensor, Inc., the Naval Research Laboratory (NRL), and the Department of Energy (DOE). This report describes the analysis algorithms developed by NRL for the new instrument and the software which embodies them

  3. Influence of the temperature in the measurement of the gamma automatic probe Gamma Tracer

    International Nuclear Information System (INIS)

    Caveda R, C.A.; Dominguez L, O.; Alonso A, D.; Montalvan E, A.; Fabelo B, O.

    2006-01-01

    In the following work an analysis of the existent relationship among the measurement of the absorbed dose rate in air due to the environmental gamma radiation and the temperature, magnitudes measured to intervals of 10 minutes by the gamma probe Gamma Tracer located in the post of occident of the National Net of Environmental Radiological Surveillance (RNVRA), in the Center of Protection and Hygiene of the Radiations (CPHR) is made. For it its were analyzed near 100,000 measurements corresponding to the period 2004-2005. For a better processing and interpretation of the data, these were analyzed with one frequency time zone and monthly using the Gamma Red software to which was necessary to add it some options. Finally it was submitted the probe to a heating process inside a stove. The results of the carried out experiments confirmed that the absorbed dose rate in air due to the environmental gamma radiation depends potentially of the probe temperature in the range of environmental temperature to which is subjected daily the same one. (Author)

  4. Hand-held electronic data collection and procedure environment

    International Nuclear Information System (INIS)

    Kennedy, E.; Doniz, K.

    1996-01-01

    As part of a CANDU Owners Group project, AECL has developed a hand-held electronic data collection and procedure environment. Integral to this environment is the C omputerized Procedure Engine . The development of the CPE allows operators, maintainers, and technical support staff to execute virtually any type of station procedure on a general-purpose PC-compatible hand-held computer. There are several advantages to using the computerized procedures: less paper use and handling, reduction in human error, reduction in rework in the field, an increase in procedural compliance, and immediate availability of data to download to databases and plant information systems. The paper describes: the advantages of using computerized procedures, why early forms of computerized procedures were inadequate, the features that the C omputerized Procedure Engine o ffers to the user, the streamlined life cycle of a computerized procedure, and field experience. The paper concludes that computerized procedures are ready for pilot applications at stations. (author)

  5. Combined approach of perioperative 18F-FDG PET/CT imaging and intraoperative 18F-FDG handheld gamma probe detection for tumor localization and verification of complete tumor resection in breast cancer

    Directory of Open Access Journals (Sweden)

    Knopp Michael V

    2007-12-01

    Full Text Available Abstract Background 18F-fluorodeoxyglucose (18F-FDG positron emission tomography/computed tomography (PET/CT has become an established method for detecting hypermetabolic sites of known and occult disease and is widely used in oncology surgical planning. Intraoperatively, it is often difficult to localize tumors and verify complete resection of tumors that have been previously detected on diagnostic PET/CT at the time of the original evaluation of the cancer patient. Therefore, we propose an innovative approach for intraoperative tumor localization and verification of complete tumor resection utilizing 18F-FDG for perioperative PET/CT imaging and intraoperative gamma probe detection. Methods Two breast cancer patients were evaluated. 18F-FDG was administered and PET/CT was acquired immediately prior to surgery. Intraoperatively, tumors were localized and resected with the assistance of a handheld gamma probe. Resected tumors were scanned with specimen PET/CT prior to pathologic processing. Shortly after the surgical procedure, patients were re-imaged with PET/CT utilizing the same preoperatively administered 18F-FDG dose. Results One patient had primary carcinoma of breast and a metastatic axillary lymph node. The second patient had a solitary metastatic liver lesion. In both cases, preoperative PET/CT verified these findings and demonstrated no additional suspicious hypermetabolic lesions. Furthermore, intraoperative gamma probe detection, specimen PET/CT, and postoperative PET/CT verified complete resection of the hypermetabolic lesions. Conclusion Immediate preoperative and postoperative PET/CT imaging, utilizing the same 18F-FDG injection dose, is feasible and image quality is acceptable. Such perioperative PET/CT imaging, along with intraoperative gamma probe detection and specimen PET/CT, can be used to verify complete tumor resection. This innovative approach demonstrates promise for assisting the oncologic surgeon in localizing and

  6. The availability of relatively cheap hand-held Global Positioning ...

    African Journals Online (AJOL)

    spamer

    conditions, so the approach failed to produce results ... Hand-held Global Positioning System (GPS) receivers provide opportunities for detailed and rapid mapping of features ..... TICKELL, W. L. N. 1968 — The biology of the great albatrosses,.

  7. Hand-held and automated breast ultrasound

    International Nuclear Information System (INIS)

    Bassett, L.W.; Gold, R.H.; Kimme-Smith, C.

    1985-01-01

    The book is a guide for physicians and technologists who use US as an adjunct to mammography; it carefully outlines the pros and cons of US of the breast and its role in the diagnosis of benign and malignant diseases. After an introduction that discusses the philosophy of breast US, the chapters cover the physics of US and instrumentation (both hand-held transducers as well as automated water path scanners), then proceed to a discussion of the normal breast. Sections on benign disorders, malignant lesions, and pitfalls of diagnosis are followed by quiz cases

  8. A new approach for the screening of carotid lesions: a 'fast-track' method with the use of new generation hand-held ultrasound devices.

    Science.gov (United States)

    Aboyans, V; Lacroix, P; Jeannicot, A; Guilloux, J; Bertin, F; Laskar, M

    2004-09-01

    We assessed the usefulness of fast-track neck sonography with a new-generation hand-held ultrasound scanner in the detection of > or =60% carotid stenosis. Patients with a past history of atherosclerotic disease or presence of risk factors were enrolled. All had fast-track carotid screening with a hand-held ultrasound scanner. Initial assessment was performed with our quick imaging protocol. A second examiner performed a conventional complete carotid duplex as gold-standard. We enrolled 197 consecutive patients with a mean age of 67 years (range 35-94). A carotid stenosis >60% was detected in 13 cases (6%). The sensitivity, specificity, positive and negative predictive value of fast-track sonography was 100%, 64%, 17% and 100%, respectively. Concomitant power Doppler imaging during the fast-track method did not improve accuracy. The use of a fast-track method with a hand-held ultrasound device can reduce the number of unnecessary carotid Duplex and enhance the screening efficiency without missing significant carotid stenoses.

  9. Radioguided surgery: First experiences with surgical gamma probe

    International Nuclear Information System (INIS)

    Vereb, M.; Bakala, J.

    2004-01-01

    Full text: Thanks to the International Atomic Energy Agency and co-operation of the Nuclear Regulatory Authority of the Slovak Republic - International and Public Relations Division, sentinel lymph node detection has been introduced in one of the regional hospitals in Slovakia. Surgical Gamma Probe, the equipment needed for this has been made available. IAEA first of all helped in organizing a workshop on Scintimammography, Sentinel Lymph Node Detection and Intra-Operative Surgical Probe in Breast Cancer, in April 2002. Education of specialists - surgeons, oncologists, and pathologists and of course radiologists helped them to better understand the subject visa-vis nuclear medicine techniques. We also started the sentinel node detection following the two-days protocol. A 57 years old female with newly detected breast carcinoma in right breast, with positive mammography was investigated. Axillary lymph nodes were not palpable. Tc-99m Nanocoll, with particles size ranging 4-100 nm, was administered, 75 MBq peritumorally + 75 MBq subdermally and a dynamic lymphoscintigraphy was acquired which showed migration of the radiotracer. Static views (after 120 min.) demonstrated 4 sentinel lymph nodes in the right axilla. No lymph node was seen in the internal mammary or left axillary region. Next day before operation about 2 ml of patten blue dye was injected around the tumor and breast was compressed for about 10 min. Identification of sentinel lymph node was done with the help of surgical gamma probe and blue tinting. We found 6 nodes, first two were not really sentinel, but they were blue. A breast conservation surgery with standard axillary lymphadenectomy was performed. Pathology revealed invasive ductal carcinoma. We understand the need to establish an algorithm of examination and treatment of patients with newly diagnosed breast carcinoma. This technology requires teamwork of surgeon, nuclear medicine physician and pathologist. Regarding radiation exposure which every

  10. Hand and shoe monitor using air ionization probes

    International Nuclear Information System (INIS)

    Fergus, R.W.

    1981-01-01

    A hand and shoe radiation monitor is provided which includes a probe support body defining a plurality of cells, within each cell there being an ionization probe. The support body provides structural strength for protecting the ionization probes from force applied to the support body during a radiation monitoring event. There is also provided a fast response time amplifier circuit for the output from the ionization probes

  11. Hand held data collection and monitoring system for nuclear facilities

    Science.gov (United States)

    Brayton, D.D.; Scharold, P.G.; Thornton, M.W.; Marquez, D.L.

    1999-01-26

    Apparatus and method is disclosed for a data collection and monitoring system that utilizes a pen based hand held computer unit which has contained therein interaction software that allows the user to review maintenance procedures, collect data, compare data with historical trends and safety limits, and input new information at various collection sites. The system has a means to allow automatic transfer of the collected data to a main computer data base for further review, reporting, and distribution purposes and uploading updated collection and maintenance procedures. The hand held computer has a running to-do list so sample collection and other general tasks, such as housekeeping are automatically scheduled for timely completion. A done list helps users to keep track of all completed tasks. The built-in check list assures that work process will meet the applicable processes and procedures. Users can hand write comments or drawings with an electronic pen that allows the users to directly interface information on the screen. 15 figs.

  12. Hand held data collection and monitoring system for nuclear facilities

    International Nuclear Information System (INIS)

    Brayton, D.D.; Scharold, P.G.; Thornton, M.W.; Marquez, D.L.

    1999-01-01

    Apparatus and method is disclosed for a data collection and monitoring system that utilizes a pen based hand held computer unit which has contained therein interaction software that allows the user to review maintenance procedures, collect data, compare data with historical trends and safety limits, and input new information at various collection sites. The system has a means to allow automatic transfer of the collected data to a main computer data base for further review, reporting, and distribution purposes and uploading updated collection and maintenance procedures. The hand held computer has a running to-do list so sample collection and other general tasks, such as housekeeping are automatically scheduled for timely completion. A done list helps users to keep track of all completed tasks. The built-in check list assures that work process will meet the applicable processes and procedures. Users can hand write comments or drawings with an electronic pen that allows the users to directly interface information on the screen. 15 figs

  13. Interactive topology optimization on hand-held devices

    DEFF Research Database (Denmark)

    Aage, Niels; Nobel-Jørgensen, Morten; Andreasen, Casper Schousboe

    2013-01-01

    This paper presents an interactive topology optimization application designed for hand-held devices running iOS or Android. The TopOpt app solves the 2D minimum compliance problem with interactive control of load and support positions as well as volume fraction. Thus, it is possible to change......OS devices from the Apple App Store, at Google Play for the Android platform, and a web-version can be run from www.topopt.dtu.dk....

  14. Handy-type gamma probe-guided sentinel lymph node biopsy for breast cancer under ambulatory local anesthesia

    International Nuclear Information System (INIS)

    Fujiwara, Ikuya; Nagata, Hiroaki; Takaki, Wataru

    2016-01-01

    Prior to surgery for clinically node-negative breast cancer, we diagnosed metastases on the basis of permanent sections and sentinel lymph node biopsy (SNB) using the combined radio isotope (RI)/blue dye method with a hand-type gamma probe under ambulatory local anesthesia. SNB was performed for 99 patients with 103 lesions, including 4 patients with bilateral breast cancer. We achieved an identification rate of 100%, in which the identification pattern included detection by RI and blue-dye in 65 patients (63.1%), detection by RI alone in 37 patients (35.9%), and blue-dye alone in one patient (1.0%). Sentinel lymph node metastasis was macrometastasis in 21 patients (20.4%), micrometastasis in 8 patients (7.8%), and isolated tumor cells in patients (4.9%). In the 80 patients who did not undergo post-SNB axillary lymph node dissection, the median observation period was 33 months and there were no recurrences in the axillary lymph nodes observed. Although the present procedure requires two surgeries, it is a useful method that enables metastasis detection and highly accurate SNB. (author)

  15. Study of the contribution of the radon in the measurement with an automatic gamma probe

    International Nuclear Information System (INIS)

    Caveda Ramos, C.A.; Dominguez Levy, O.; Alonso Abad, D.; Montalvan Estrada, A.; Fabelo Bonet, O.

    2008-01-01

    In this work, study about the influence of the radon in the daily measurements of the dose rate absorbed in air due to the environmental gamma radiation is achieved. This magnitude is measured each ten minutes for the Gamma Tracer probe, which is located in the western station of the National Network of Environmental Radiological Surveillance of the Republic of Cuba, this station belongs to the Center of Protection and Hygiene of the Radiations (CPHR). For achieving such study approximately 157 680 measurements of the gamma dose rate corresponding the period 2004-2006 were analyzed. The gamma probe used has two independent counter channels which are both complemented with a Geiger-Muller detector; also it can only detect gamma radiation and perform measurements of the gamma dose rate between 8.7 n Gy/h and 8.7 mGy/h. This probe is located at the height of 3.5 m and is exposed to the sun rays directly. For improving the interpretation of the data, the average of all the values of gamma dose rate was calculated, for each hour of the 365 days of the year. The values were also monthly averaged out. The data were processed by employing the software Gamma Red which was improved by adding some options. A comparison between the results obtained and the annual radon variation internationally published was made. With the present study, it was proved that the main contribution to the daily measurements of the dose rate absorbed in the air due to environmental gamma radiation, on stable weather conditions, is associated with the radon daughters which emit gamma radiation. (author)

  16. Analysis of Information Remaining on Hand Held Devices Offered for Sale on the Second Hand Market

    Directory of Open Access Journals (Sweden)

    Andy Jones

    2008-06-01

    Full Text Available The ownership and use of mobile phones, Personal Digital Assistants and other hand held devices is now ubiquitous both for home and business use. The majority of these devices have a high initial cost, a relatively short period before they become obsolescent and a relatively low second hand value.  As a result of this, when the devices are replaced, there are indications that they tend to be discarded.  As technology has continued to develop, it has led to an increasing diversity in the number and type of devices that are available, and the processing power and the storage capacity of the digital storage in the device. All organisations, whether in the public or private sector increasingly use hand held devices that contain digital media for the storage of information relating to their business, their employees or their customers. Similarly, individual private users increasingly use hand held devices containing digital media for the storage of information relating to their private lives.The research revealed that a significant number of organisations and private users are ignorant or misinformed about the volume and type of information that is stored on the hand held devices and the media on which it is stored.  It is apparent that they have either not considered, or are unaware of, the potential impact of this information becoming available to their competitors or those with criminal intent.This main purpose of this study was to gain an understanding of the volume and type of information that may remain on hand held devices that are offered for sale on the second hand market.  A second aim of the research was to determine the level of damage that could, potentially be caused, if the information that remains on the devices fell into the wrong hands.  The study examined a number of hand held devices that had been obtained from sources in the UK and Australia that ranged from internet auction sites, to private sales and commercial

  17. Validity of maximal isometric knee extension strength measurements obtained via belt-stabilized hand-held dynamometry in healthy adults.

    Science.gov (United States)

    Ushiyama, Naoko; Kurobe, Yasushi; Momose, Kimito

    2017-11-01

    [Purpose] To determine the validity of knee extension muscle strength measurements using belt-stabilized hand-held dynamometry with and without body stabilization compared with the gold standard isokinetic dynamometry in healthy adults. [Subjects and Methods] Twenty-nine healthy adults (mean age, 21.3 years) were included. Study parameters involved right side measurements of maximal isometric knee extension strength obtained using belt-stabilized hand-held dynamometry with and without body stabilization and the gold standard. Measurements were performed in all subjects. [Results] A moderate correlation and fixed bias were found between measurements obtained using belt-stabilized hand-held dynamometry with body stabilization and the gold standard. No significant correlation and proportional bias were found between measurements obtained using belt-stabilized hand-held dynamometry without body stabilization and the gold standard. The strength identified using belt-stabilized hand-held dynamometry with body stabilization may not be commensurate with the maximum strength individuals can generate; however, it reflects such strength. In contrast, the strength identified using belt-stabilized hand-held dynamometry without body stabilization does not reflect the maximum strength. Therefore, a chair should be used to stabilize the body when performing measurements of maximal isometric knee extension strength using belt-stabilized hand-held dynamometry in healthy adults. [Conclusion] Belt-stabilized hand-held dynamometry with body stabilization is more convenient than the gold standard in clinical settings.

  18. Intra-operative ultrasound hand-held strain imaging for the visualization of ablations produced in the liver with a toroidal HIFU transducer: first in vivo results

    Energy Technology Data Exchange (ETDEWEB)

    Chenot, J; Melodelima, D; N' Djin, W A; Souchon, Remi; Rivoire, M; Chapelon, J Y, E-mail: jeremy.chenot@inserm.f [Inserm, U556, Lyon, F-69003 (France)

    2010-06-07

    The use of hand-held ultrasound strain imaging for the intra-operative real-time visualization of HIFU (high-intensity focused ultrasound) ablations produced in the liver by a toroidal transducer was investigated. A linear 12 MHz ultrasound imaging probe was used to obtain radiofrequency signals. Using a fast cross-correlation algorithm, strain images were calculated and displayed at 60 frames s{sup -1}, allowing the use of hand-held strain imaging intra-operatively. Fourteen HIFU lesions were produced in four pigs. Intra-operative strain imaging of HIFU ablations in the liver was feasible owing to the high frame rate. The correlation between dimensions measured on gross pathology and dimensions measured on B-mode images and on strain images were R = 0.72 and R = 0.94 respectively. The contrast between ablated and non-ablated tissue was significantly higher (p < 0.05) in the strain images (22 dB) than in the B-mode images (9 dB). Strain images allowed equivalent or improved definition of ablated regions when compared with B-mode images. Real-time intra-operative hand-held strain imaging seems to be a promising complement to conventional B-mode imaging for the guidance of HIFU ablations produced in the liver during an open procedure. These results support that hand-held strain imaging outperforms conventional B-mode ultrasound and could potentially be used for the assessment of thermal therapies.

  19. Criteria for a comparative assessment on handheld gamma-ray measurement tools

    International Nuclear Information System (INIS)

    Feichtinger, J.; Schwaiger, M.; Schmitzer, C.; Kindl, P.

    2001-01-01

    Full text: The radionuclide laboratories at the Austrian Research Centres Seibersdorf are strongly involved in radiation protection of public and employees as well as in environmental monitoring with special concern to gamma spectrometric measurements. Hence, field measurements and therefore the subject of hand-held measurement devices is a topic of main interest. Taking into consideration, that these hand-held measurement tool are further used in critical and sensitive operations, as for example by the IAEA Safeguards or by CTBTO On-Site inspectors, a standard for characterising these gamma measurement tools seems to be sound as necessary. The poster presents a set of technical criteria as well as limiting values, which allows an objective comparison of hand-held measurement devices. The criteria can be divided into three individual parts: radiometric characteristics, ergonomics and usability in field operations. The main criteria for testing the radiometry performance of hand-held measurement devices are sensitivity, efficiency, energy response, energy resolution and nuclide identification or not identification (if necessary), detection probability, dose rate indication, uncertainty, etc. The ergonomic test contains as dominating parts handling and quality of the manual. To evaluate the applicability in field operations different environmental conditions (e.g. light conditions, temperature range, moisture...) as well as battery lifetime and weight should be taken into account. These criteria may vary in dependence of the requirements or limitations given by various external conditions, but still a standard to evaluate and will give the opportunity to provide an objective comparison. (author)

  20. Study, development and clinical evaluation of a per-operative {gamma} imager; Etude, developpement et evaluation clinique d`un imageur {gamma} per-operatoire

    Energy Technology Data Exchange (ETDEWEB)

    Menard, Laurent [Inst. de Physique Nucleaire, Paris-11 Univ., 91 - Orsay (France)

    1999-01-19

    The precise localization and complete surgical ablation of tumors are one of the most important procedures in cancer treatment. In that context, the use, in operating room, of light hand-held detectors associated to radiopharmaceutical compounds for tumor labelling, plays a significant role in assisting surgeons in real-time detection of lesion. The POCI gamma imaging probe (Per-Operative Compact Imager), which is presented here, is precisely dedicated to improve the radio-guided operative cancer surgery efficiency by bringing a new tool discriminating between healthy and pathological tissues. To match the specifications of intra-operative detection, we chose to build our camera around an intensified position sensitive diode which appeared to be particularly suitable to achieve a high resolution small size imager. The optimal geometry of two gamma detection head modules, composed of parallel hole collimators and scintillation crystals, was then investigated by numerical simulations. From these technological solutions, a first prototype of POCI with a 24 mm diameter field of view has been developed. Its characterization has put forward a millimeter spatial resolution and a detection efficiency comparable to that of clinical gamma cameras and in agreement with the numerical predictions. Finally, in collaboration with Gustave Roussy, a first clinical evaluation of the POCI camera has been performed for sentinel ganglion pre-operative localization in patients afflicted by malignant melanomas or breast cancers. The preliminary results have already shown that the performances of POCI are compatible with intraoperative imaging purposes and suggest how this camera can boost the success rate of tumor removal surgeries for other cancerous diseases. (author) 100 refs., 67 figs., 11 tabs.

  1. Intraoperative use of gamma-detecting probes to localize neuroendocrine tumor

    International Nuclear Information System (INIS)

    Adams, S.; Baum, R.P.

    2000-01-01

    Neuroendocrine tumors are characterized by the expression of different peptides and biogenic amines. These rare tumors tend to grow slowly and are notoriously difficult to localize, at least in the early stages. Surgical removal is the only definitive therapeutic option for neuroendocrine tumors and relief from hyper functional status. The effectiveness of surgical treatment is invariably dependent upon the complete surgical excision of all tumor tissue, because microscopic and occult disease not readily seen by the surgeon may remain in sit, leading to shortened survival. Radio guided surgery (RGS) is an intraoperative technique that enables the surgeon to localize radiolabelled tissue based on the characteristics of the various tissues. For imaging recurrent MTC (Medullary Thyroid Cancer) many radiopharmaceuticals have been used to visualize tumor sites, but none of them has shown excellent sensitivity. Preoperative somatostatin receptor scintigraphy and intraoperative RGS in patients with recurrent MTC demonstrate only part of the tumor sites and cannot visualize small tumor sites (less than 10 mm). In patients with recurrent MTC, intraoperative gamma probe examination is able to localize over 30% more tumor lesions when compared with conventional preoperative imaging modalities and surgical findings. In addition to scintigraphy of the adrenal glands by precursors of adrenal hormones, imaging with a radiolabelled somatostatin analogue is possible; however ( 111 In-DTPA-D-Phe 1 )-pentetreotide is not specific for any adrenal disease or function and the relatively high radioligand accumulation in the kidneys limited the use for detection of tumors in the area of the adrenal glands

  2. Intraoperative use of gamma-detecting probes to localize neuroendocrine tumor

    Energy Technology Data Exchange (ETDEWEB)

    Adams, S. [Johann Wolfgang Goethe Univ., Frankfurt/Main (Germany). Medical Center, Dept. of Nuclear Medicine; Baum, R.P. [Zentralklinik Bad Berka GmbH, Bad Berka (Germany). Clinic of Nuclear Medicine/PET Center

    2000-03-01

    Neuroendocrine tumors are characterized by the expression of different peptides and biogenic amines. These rare tumors tend to grow slowly and are notoriously difficult to localize, at least in the early stages. Surgical removal is the only definitive therapeutic option for neuroendocrine tumors and relief from hyper functional status. The effectiveness of surgical treatment is invariably dependent upon the complete surgical excision of all tumor tissue, because microscopic and occult disease not readily seen by the surgeon may remain in sit, leading to shortened survival. Radio guided surgery (RGS) is an intraoperative technique that enables the surgeon to localize radiolabelled tissue based on the characteristics of the various tissues. For imaging recurrent MTC (Medullary Thyroid Cancer) many radiopharmaceuticals have been used to visualize tumor sites, but none of them has shown excellent sensitivity. Preoperative somatostatin receptor scintigraphy and intraoperative RGS in patients with recurrent MTC demonstrate only part of the tumor sites and cannot visualize small tumor sites (less than 10 mm). In patients with recurrent MTC, intraoperative gamma probe examination is able to localize over 30% more tumor lesions when compared with conventional preoperative imaging modalities and surgical findings. In addition to scintigraphy of the adrenal glands by precursors of adrenal hormones, imaging with a radiolabelled somatostatin analogue is possible; however ({sup 111}In-DTPA-D-Phe{sup 1})-pentetreotide is not specific for any adrenal disease or function and the relatively high radioligand accumulation in the kidneys limited the use for detection of tumors in the area of the adrenal glands.

  3. Comparison of two threshold detection criteria methodologies for determination of probe positivity for intraoperative in situ identification of presumed abnormal 18F-FDG-avid tissue sites during radioguided oncologic surgery.

    Science.gov (United States)

    Chapman, Gregg J; Povoski, Stephen P; Hall, Nathan C; Murrey, Douglas A; Lee, Robert; Martin, Edward W

    2014-09-13

    Intraoperative in situ identification of (18)F-FDG-avid tissue sites during radioguided oncologic surgery remains a significant challenge for surgeons. The purpose of our study was to evaluate the 1.5-to-1 ratiometric threshold criteria method versus the three-sigma statistical threshold criteria method for determination of gamma detection probe positivity for intraoperative in situ identification of presumed abnormal (18)F-FDG-avid tissue sites in a manner that was independent of the specific type of gamma detection probe used. From among 52 patients undergoing appropriate in situ evaluation of presumed abnormal (18)F-FDG-avid tissue sites during (18)F-FDG-directed surgery using 6 available gamma detection probe systems, a total of 401 intraoperative gamma detection probe measurement sets of in situ counts per second measurements were cumulatively taken. For the 401 intraoperative gamma detection probe measurement sets, probe positivity was successfully met by the 1.5-to-1 ratiometric threshold criteria method in 150/401 instances (37.4%) and by the three-sigma statistical threshold criteria method in 259/401 instances (64.6%) (P < 0.001). Likewise, the three-sigma statistical threshold criteria method detected true positive results at target-to-background ratios much lower than the 1.5-to-1 target-to-background ratio of the 1.5-to-1 ratiometric threshold criteria method. The three-sigma statistical threshold criteria method was significantly better than the 1.5-to-1 ratiometric threshold criteria method for determination of gamma detection probe positivity for intraoperative in situ detection of presumed abnormal (18)F-FDG-avid tissue sites during radioguided oncologic surgery. This finding may be extremely important for reshaping the ongoing and future research and development of gamma detection probe systems that are necessary for optimizing the in situ detection of radioisotopes of higher-energy gamma photon emissions used during radioguided oncologic surgery.

  4. An integrated portable hand-held analyser for real-time isothermal nucleic acid amplification

    International Nuclear Information System (INIS)

    Smith, Matthew C.; Steimle, George; Ivanov, Stan; Holly, Mark; Fries, David P.

    2007-01-01

    A compact hand-held heated fluorometric instrument for performing real-time isothermal nucleic acid amplification and detection is described. The optoelectronic instrument combines a Printed Circuit Board/Micro Electro Mechanical Systems (PCB/MEMS) reaction detection/chamber containing an integrated resistive heater with attached miniature LED light source and photo-detector and a disposable glass waveguide capillary to enable a mini-fluorometer. The fluorometer is fabricated and assembled in planar geometry, rolled into a tubular format and packaged with custom control electronics to form the hand-held reactor. Positive or negative results for each reaction are displayed to the user using an LED interface. Reaction data is stored in FLASH memory for retrieval via an in-built USB connection. Operating on one disposable 3 V lithium battery >12, 60 min reactions can be performed. Maximum dimensions of the system are 150 mm (h) x 48 mm (d) x 40 mm (w), the total instrument weight (with battery) is 140 g. The system produces comparable results to laboratory instrumentation when performing a real-time nucleic acid sequence-based amplification (NASBA) reaction, and also displayed comparable precision, accuracy and resolution to laboratory-based real-time nucleic acid amplification instrumentation. A good linear response (R 2 = 0.948) to fluorescein gradients ranging from 0.5 to 10 μM was also obtained from the instrument indicating that it may be utilized for other fluorometric assays. This instrument enables an inexpensive, compact approach to in-field genetic screening, providing results comparable to laboratory equipment with rapid user feedback as to the status of the reaction

  5. An integrated portable hand-held analyser for real-time isothermal nucleic acid amplification

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Matthew C. [College of Marine Science, University of South Florida, St Petersburg, FL (United States)], E-mail: msmith@marine.usf.edu; Steimle, George; Ivanov, Stan; Holly, Mark; Fries, David P. [College of Marine Science, University of South Florida, St Petersburg, FL (United States)

    2007-08-29

    A compact hand-held heated fluorometric instrument for performing real-time isothermal nucleic acid amplification and detection is described. The optoelectronic instrument combines a Printed Circuit Board/Micro Electro Mechanical Systems (PCB/MEMS) reaction detection/chamber containing an integrated resistive heater with attached miniature LED light source and photo-detector and a disposable glass waveguide capillary to enable a mini-fluorometer. The fluorometer is fabricated and assembled in planar geometry, rolled into a tubular format and packaged with custom control electronics to form the hand-held reactor. Positive or negative results for each reaction are displayed to the user using an LED interface. Reaction data is stored in FLASH memory for retrieval via an in-built USB connection. Operating on one disposable 3 V lithium battery >12, 60 min reactions can be performed. Maximum dimensions of the system are 150 mm (h) x 48 mm (d) x 40 mm (w), the total instrument weight (with battery) is 140 g. The system produces comparable results to laboratory instrumentation when performing a real-time nucleic acid sequence-based amplification (NASBA) reaction, and also displayed comparable precision, accuracy and resolution to laboratory-based real-time nucleic acid amplification instrumentation. A good linear response (R{sup 2} = 0.948) to fluorescein gradients ranging from 0.5 to 10 {mu}M was also obtained from the instrument indicating that it may be utilized for other fluorometric assays. This instrument enables an inexpensive, compact approach to in-field genetic screening, providing results comparable to laboratory equipment with rapid user feedback as to the status of the reaction.

  6. Hand-held cell phone use while driving legislation and observed driver behavior among population sub-groups in the United States.

    Science.gov (United States)

    Rudisill, Toni M; Zhu, Motao

    2017-05-12

    Cell phone use behaviors are known to vary across demographic sub-groups and geographic locations. This study examined whether universal hand-held calling while driving bans were associated with lower road-side observed hand-held cell phone conversations across drivers of different ages (16-24, 25-59, ≥60 years), sexes, races (White, African American, or other), ruralities (suburban, rural, or urban), and regions (Northeast, Midwest, South, and West). Data from the 2008-2013 National Occupant Protection Use Survey were merged with states' cell phone use while driving legislation. The exposure was presence of a universal hand-held cell phone ban at time of observation. Logistic regression was used to assess the odds of drivers having a hand-held cell phone conversation. Sub-groups differences were assessed using models with interaction terms. When universal hand-held cell phone bans were effective, hand-held cell phone conversations were lower across all driver demographic sub-groups and regions. Sub-group differences existed among the sexes (p-value, phone bans, the adjusted odds ratio (aOR) of a driver hand-held phone conversation was 0.34 [95% confidence interval (CI): 0.28, 0.41] for females versus 0.47 (CI 0.40, 0.55) for males and 0.31 (CI 0.25, 0.38) for drivers in Western states compared to 0.47 (CI 0.30, 0.72) in the Northeast and 0.50 (CI 0.38, 0.66) in the South. The presence of universal hand-held cell phone bans were associated lower hand-held cell phone conversations across all driver sub-groups and regions. Hand-held phone conversations were particularly lower among female drivers and those from Western states when these bans were in effect. Public health interventions concerning hand-held cell phone use while driving could reasonably target all drivers.

  7. Hand-held cell phone use while driving legislation and observed driver behavior among population sub-groups in the United States

    Directory of Open Access Journals (Sweden)

    Toni M. Rudisill

    2017-05-01

    Full Text Available Abstract Background Cell phone use behaviors are known to vary across demographic sub-groups and geographic locations. This study examined whether universal hand-held calling while driving bans were associated with lower road-side observed hand-held cell phone conversations across drivers of different ages (16–24, 25–59, ≥60 years, sexes, races (White, African American, or other, ruralities (suburban, rural, or urban, and regions (Northeast, Midwest, South, and West. Methods Data from the 2008–2013 National Occupant Protection Use Survey were merged with states’ cell phone use while driving legislation. The exposure was presence of a universal hand-held cell phone ban at time of observation. Logistic regression was used to assess the odds of drivers having a hand-held cell phone conversation. Sub-groups differences were assessed using models with interaction terms. Results When universal hand-held cell phone bans were effective, hand-held cell phone conversations were lower across all driver demographic sub-groups and regions. Sub-group differences existed among the sexes (p-value, <0.0001 and regions (p-value, 0.0003. Compared to states without universal hand-held cell phone bans, the adjusted odds ratio (aOR of a driver hand-held phone conversation was 0.34 [95% confidence interval (CI: 0.28, 0.41] for females versus 0.47 (CI 0.40, 0.55 for males and 0.31 (CI 0.25, 0.38 for drivers in Western states compared to 0.47 (CI 0.30, 0.72 in the Northeast and 0.50 (CI 0.38, 0.66 in the South. Conclusions The presence of universal hand-held cell phone bans were associated lower hand-held cell phone conversations across all driver sub-groups and regions. Hand-held phone conversations were particularly lower among female drivers and those from Western states when these bans were in effect. Public health interventions concerning hand-held cell phone use while driving could reasonably target all drivers.

  8. Gamma-ray imaging system. Innovative technology summary report

    International Nuclear Information System (INIS)

    1998-11-01

    The RadScan 600 gamma-ray imaging system is designed to survey large surface areas for radiological contamination with accuracy and efficiency. The resulting survey data are clear, concise, and precise in describing how much contamination is present at exact locations. Data can be permanently stored electronically and on video tape, making storage and retrieval economical and efficient. This technology can perform accurate measurements in high radiation contamination areas while minimizing worker exposure. The RadScan 600 system is a safe and effective alternative to hand-held radiation detection devices. Performance data of the demonstrated survey area of the RadScan 600 system versus the baseline, which is the hand-held radiation detection devices (RO-2 and RO-7) for a given survey, production rate is 72% of the baseline. It should be noted that the innovative technology provides 100% coverage at a unit cost of $8.64/m 2 versus a static measurement of a unit cost of $1.61/m 2 for the baseline

  9. Combining heterogenous features for 3D hand-held object recognition

    Science.gov (United States)

    Lv, Xiong; Wang, Shuang; Li, Xiangyang; Jiang, Shuqiang

    2014-10-01

    Object recognition has wide applications in the area of human-machine interaction and multimedia retrieval. However, due to the problem of visual polysemous and concept polymorphism, it is still a great challenge to obtain reliable recognition result for the 2D images. Recently, with the emergence and easy availability of RGB-D equipment such as Kinect, this challenge could be relieved because the depth channel could bring more information. A very special and important case of object recognition is hand-held object recognition, as hand is a straight and natural way for both human-human interaction and human-machine interaction. In this paper, we study the problem of 3D object recognition by combining heterogenous features with different modalities and extraction techniques. For hand-craft feature, although it reserves the low-level information such as shape and color, it has shown weakness in representing hiconvolutionalgh-level semantic information compared with the automatic learned feature, especially deep feature. Deep feature has shown its great advantages in large scale dataset recognition but is not always robust to rotation or scale variance compared with hand-craft feature. In this paper, we propose a method to combine hand-craft point cloud features and deep learned features in RGB and depth channle. First, hand-held object segmentation is implemented by using depth cues and human skeleton information. Second, we combine the extracted hetegerogenous 3D features in different stages using linear concatenation and multiple kernel learning (MKL). Then a training model is used to recognize 3D handheld objects. Experimental results validate the effectiveness and gerneralization ability of the proposed method.

  10. Integrated ultrasound and gamma imaging probe for medical diagnosis

    International Nuclear Information System (INIS)

    Pani, R.; Pellegrini, R.; Cinti, M. N.; Polito, C.; Orlandi, C.; Fabbri, A.; Vincentis, G. De

    2016-01-01

    In the last few years, integrated multi-modality systems have been developed, aimed at improving the accuracy of medical diagnosis correlating information from different imaging techniques. In this contest, a novel dual modality probe is proposed, based on an ultrasound detector integrated with a small field of view single photon emission gamma camera. The probe, dedicated to visualize small organs or tissues located at short depths, performs dual modality images and permits to correlate morphological and functional information. The small field of view gamma camera consists of a continuous NaI:Tl scintillation crystal coupled with two multi-anode photomultiplier tubes. Both detectors were characterized in terms of position linearity and spatial resolution performances in order to guarantee the spatial correspondence between the ultrasound and the gamma images. Finally, dual-modality images of custom phantoms are obtained highlighting the good co-registration between ultrasound and gamma images, in terms of geometry and image processing, as a consequence of calibration procedures

  11. Evaluation of the Gen-Probe DNA probe for the detection of legionellae in culture

    International Nuclear Information System (INIS)

    Edelstein, P.H.

    1986-01-01

    A commercial DNA probe kit designed to detect rRNA from legionellae was evaluated for its ability to correctly discriminate between legionellae and non-legionellae taken from culture plates. The probe kit, made by the Gen-Probe Corp. (San Diego, Calif.), was radiolabeled with 125 I, and probe bacterial RNA hybridization, detected in a simple one-tube system hybridization assay, was quantitated with a gamma counter. A total of 156 Legionella sp. strains were tested, of which 125 were Legionella pneumophila and the remainder were strains from 21 other Legionella spp. A total of 106 gram-negative non-legionellae, isolated from human respiratory tract (81%) and other body site (19%) specimens, were also tested; 14 genera and 28 species were represented. The probe easily distinguished all of the legionellae from the non-legionellae. The average legionellae/non-legionellae hybridization ratio was 42:1, and the lowest ratio was 2:1; a minor modification in the procedure increased the lowest ratio to 5:1. In addition to correctly identifying all Legionella species, the probe was able to separate some of the various species of Legionella. L. pneumophila strains hybridized more completely to the probe than did the other Legionella spp.; L. wadsworthii and L. oakridgensis hybridized only about 25% of the probe relative to L. pneumophila. Some strains of phenotypically identified L. pneumophila had much lower hybridization to the probe than other members of the species and may represent a new Legionella species. The simplicity of the technique and specificity of the probe make it a good candidate for confirming the identity of legionellae in culture

  12. The external and internal radioimmunodetection of metastatic lymph nodes of breast cancer

    International Nuclear Information System (INIS)

    Long Li

    1991-01-01

    A radiolabeled monoclonal antibody (McAb) 6c6 was used to detect the metastatic lymph nodes of breast cancer externally and internally. 111 In was labeled to 6c6 by DTPA method. Iodogen method was used to label 131 I. The radiolabeled 6c6 was injected into the web space of each hand in seven women with breast cancer and one with benign breast tumor. The scans were positive in two axillae with palpable nodes and four with impalpable nodes. Pathologic examination later confirmed metastases in five of the axillae. Two axillae, one of them with palpable nodes, showed negative result, and here no tumor cells were found pathologically. Intraoperative metastatic lymph node detection with a hand-held gamma probe was carried out in six patients. 24 lymph nodes were measured with 17% (1/6) false negative and no false positive result (0/18), indicating that the result detected by the hand-held gamma probe presents the real radioactivity of the tissues being examined. There were 60 lymph nodes that were removed and detected again by well-shape detector after operation. The false positive rate was 14% (6/42), and the false negative rate was 11% (2/18), indicating that the radiolabeled McAb 6c6 could specifically combine with the metastatic lymph nodes of breast cancer in vivo

  13. Extra-light gamma-ray imager for safeguards and homeland security

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, Oleg P.; Semin, Ilya A.; Potapov, Victor N.; Stepanov, Vyacheslav E. [National Research Centre Kurchatov Institute, Moscow, 123182, (Russian Federation)

    2015-07-01

    Gamma-ray imaging is the most important way to identify unknown gamma-ray emitting objects in decommissioning, security, overcoming accidents. Over the past two decades a system for producing of gamma images in these conditions became more or less portable devices. But in recent years these systems have become the hand-held devices. This is very important, especially in emergency situations, and measurements for safety reasons. We describe the first integrated hand-held instrument for emergency and security applications. The device is based on the coded aperture image formation, position sensitive gamma-ray (X-ray) detector Medipix2 (detectors produces by X-ray Imaging Europe) and tablet computer. The development was aimed at creating a very low weight system with high angular resolution. We present some sample gamma-ray images by camera. Main estimated parameters of the system are the following. The field of view video channel ∼ 490 deg. The field of view gamma channel ∼ 300 deg. The sensitivity of the system with a hexagonal mask for the source of Cs-137 (Eg = 662 keV), is in units of dose D ∼ 100 mR. This option is less then order of magnitude worse than for the heavy, non-hand-held systems (e.g., gamma-camera Cartogam, by Canberra.) The angular resolution of the gamma channel for the sources of Cs-137 (Eg = 662 keV) is about 1.20 deg. (authors)

  14. Suitability of capillary blood obtained by a minimally invasive lancet technique to detect subclinical ketosis in dairy cows by using 3 different electronic hand-held devices.

    Science.gov (United States)

    Kanz, P; Drillich, M; Klein-Jöbstl, D; Mair, B; Borchardt, S; Meyer, L; Schwendenwein, I; Iwersen, M

    2015-09-01

    The objective of this study was to evaluate the suitability of capillary blood obtained by a minimally invasive lancet technique to detect subclinical ketosis in 49 prepartum and 191 postpartum Holstein-Friesian cows using 3 different electronic hand-held devices [FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini), NovaVet (NOV, Nova Biomedical)]. The β-hydroxybutyrate (BHBA) concentration in serum harvested from coccygeal blood samples was analyzed in a laboratory and used as a reference value. Capillary samples were obtained from the skin of the exterior vulva by using 1 of 3 different lancets. In all samples, the concentration of BHBA was immediately analyzed with all 3 hand-held devices used in random order. All lancets used in the study were eligible for capillary blood collection but differed in the total number of incisions needed. Spearman correlation coefficients between the BHBA concentrations in capillary blood and the reference test were highly significant with 83% for the FSP, 73% for the NOV, and 63% for the GLX. Using capillary blood, the FSP overestimated the mean BHBA concentration compared with the reference test (+0.08 mmol/L), whereas the GLX and NOV underestimated the mean concentration (-0.07 and -0.01 mmol/L). When a BHBA concentration of 1.2 mmol/L in serum was used to define subclinical ketosis, the corresponding analyses of receiver operating characteristics resulted in optimized thresholds for capillary blood of 1.1 mmol/L for the NOV and GLX devices, and of 1.0 mmol/L for the FSP. Based on these thresholds, sensitivities (Se) and specificities (Sp) were 89 and 84% for the NOV, 80 and 89% for the GLX, and 100 and 76% for the FSP. Based on a serum BHBA concentration of 1.4 mmol/L, analyses of receiver operating characteristics resulted in optimized cut-offs of 1.4 mmol/L for the FSP (Se 100%, Sp 92%), 1.3 mmol/L for the NOV (Se 80%, Sp 95%), and 1.1 mmol/L (Se 90%, Sp 85%) for the GLX. Using these optimized thresholds

  15. Influence of the temperature in the measurement of the gamma automatic probe Gamma Tracer; Influencia de la temperatura en la medicion de la sonda gamma automatica Gamma Tracer

    Energy Technology Data Exchange (ETDEWEB)

    Caveda R, C.A.; Dominguez L, O.; Alonso A, D. [CPHR, Calle 20 No. 4113 e/41 y 47, Playa, C.P. 11300, A.P. 6195, C.P. 10600 La Habana (Cuba); Montalvan E, A.; Fabelo B, O. [CIAC, Ave. Finlay Km 2 1/2, Rpto. Puerto Principe, Camaguey 70800 (Cuba)]. e-mail: caveda@cphr.edu.cu

    2006-07-01

    In the following work an analysis of the existent relationship among the measurement of the absorbed dose rate in air due to the environmental gamma radiation and the temperature, magnitudes measured to intervals of 10 minutes by the gamma probe Gamma Tracer located in the post of occident of the National Net of Environmental Radiological Surveillance (RNVRA), in the Center of Protection and Hygiene of the Radiations (CPHR) is made. For it its were analyzed near 100,000 measurements corresponding to the period 2004-2005. For a better processing and interpretation of the data, these were analyzed with one frequency time zone and monthly using the Gamma Red software to which was necessary to add it some options. Finally it was submitted the probe to a heating process inside a stove. The results of the carried out experiments confirmed that the absorbed dose rate in air due to the environmental gamma radiation depends potentially of the probe temperature in the range of environmental temperature to which is subjected daily the same one. (Author)

  16. Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children

    Directory of Open Access Journals (Sweden)

    Janson C

    2006-04-01

    Full Text Available Abstract Background Exhaled nitric oxide (NO measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO was compared with a standard stationary chemiluminescence unit (NIOX. Methods A total of 71 subjects (6–60 years; 36 males, both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots, measurement feasibility (success rate with 6 attempts and repeatability (intrasubject SD. Results Success rate was high (≥ 84% in both devices for both adults and children. The subjects represented a FENO range of 8–147 parts per billion (ppb. When comparing the mean of three measurements (n = 61, the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. Conclusion The hand-held device (NIOX MINO and the stationary system (NIOX are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO is used. The hand-held device shows good repeatability, and it

  17. Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children.

    Science.gov (United States)

    Alving, K; Janson, C; Nordvall, L

    2006-04-20

    Exhaled nitric oxide (NO) measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO) was compared with a standard stationary chemiluminescence unit (NIOX). A total of 71 subjects (6-60 years; 36 males), both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s) in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots), measurement feasibility (success rate with 6 attempts) and repeatability (intrasubject SD). Success rate was high (> or = 84%) in both devices for both adults and children. The subjects represented a FENO range of 8-147 parts per billion (ppb). When comparing the mean of three measurements (n = 61), the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. The hand-held device (NIOX MINO) and the stationary system (NIOX) are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO) is used. The hand-held device shows good repeatability, and it can be used successfully on adults and most children

  18. How to use hand-held computers to evaluate wood drying.

    Science.gov (United States)

    Howard N. Rosen; Darrell S. Martin

    1985-01-01

    Techniques have been developed to evaluate end generate wood drying curves with hand-held computers (3-5K memory). Predictions of time to dry to a specific moisture content, drying rates, and other characteristics of wood drying curves can be made. The paper describes the development of programs and illustrates their use.

  19. Development and performance of a hand-held CZT detector for in-situ measurements at the emergency response

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Young Yong; Chung, Kun Ho; Kim, Chang Jong; Lee, Wan No; Choi, Geun Sik; Kang, Mun Ja [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Yoon, Jin [SI Detection Co. Ltd, Daejeon (Korea, Republic of)

    2016-06-15

    A hand-held detector for an emergency response was developed for nuclide identification and to estimate the information of the ambient dose rate in the scene of an accident as well as the radioactivity of the contaminants. To achieve this, the most suitable sensor was first selected as a cadmium zinc telluride (CZT) semiconductor and the signal processing unit from a sensor and the signal discrimination and storage unit were successfully manufactured on a printed circuit board. The performance of the developed signal processing unit was then evaluated to have an energy resolution of about 14 keV at 662 keV. The system control unit was also designed to operate the CZT detector, monitor the detector, battery, and interface status, and check and transmit the measured results of the ambient dose rate and radioactivity. In addition, a collimator, which can control the inner radius, and the airborne dust sampler, which consists of an air filter and charcoal filter, were developed and mounted to the developed CZT detector for the quick and efficient response of a nuclear accident. The hand-held CZT detector was developed to make the in-situ gamma-ray spectrometry and its performance was checked to have a good energy resolution. In addition, the collimator and the airborne dust sampler were developed and mounted to the developed CZT detector for a quick and efficient response to a nuclear accident.

  20. PET-Probe: Evaluation of Technical Performance and Clinical Utility of a Handheld High-Energy Gamma Probe in Oncologic Surgery.

    Science.gov (United States)

    Gulec, Seza A; Daghighian, Farhad; Essner, Richard

    2016-12-01

    Positron emission tomography (PET) has become an invaluable part of patient evaluation in surgical oncology. PET is less than optimal for detecting lesions PET-positive lesions can be challenging as a result of difficulties in surgical exposure. We undertook this investigation to assess the utility of a handheld high-energy gamma probe (PET-Probe) for intraoperative identification of 18 F-deoxyglucose (FDG)-avid tumors. Forty patients underwent a diagnostic whole-body FDG-PET scan for consideration for surgical exploration and resection. Before surgery, all patients received an intravenous injection of 7 to 10 mCi of FDG. At surgery, the PET-Probe was used to determine absolute counts per second at the known tumor site(s) demonstrated by whole-body PET and at adjacent normal tissue (at least 4 cm away from tumor-bearing sites). Tumor-to-background ratios were calculated. Thirty-two patients (80%) underwent PET-Probe-guided surgery with therapeutic intent in a recurrent or metastatic disease setting. Eight patients underwent surgery for diagnostic exploration. Anatomical locations of the PET-identified lesions were neck and supraclavicular (n = 8), axilla (n = 5), groin and deep iliac (n = 4), trunk and extremity soft tissue (n = 3), abdominal and retroperitoneal (n = 19), and lung (n = 2). PET-Probe detected all PET-positive lesions. The PET-Probe was instrumental in localization of lesions in 15 patients that were not immediately apparent by surgical exploration. The PET-Probe identified all lesions demonstrated by PET scanning and, in selected cases, was useful in localizing FDG-avid disease not seen with conventional PET scanning.

  1. 78 FR 27441 - NIJ Evaluation of Hand-Held Cell Phone Detector Devices

    Science.gov (United States)

    2013-05-10

    ...The National Institute of Justice (NIJ) is soliciting interest in supplying hand-held cell phone detector devices for participation in an evaluation by the NIJ Corrections Technology Center of Excellence (CXCoE).

  2. 78 FR 73415 - Safety Standard for Hand-Held Infant Carriers

    Science.gov (United States)

    2013-12-06

    ... modifications to the ASTM test procedure set forth in ASTM F2050-12 so that the test produces more repeatable... skills necessary for the preparation of reports or records; and a description of the steps the agency has... the Rule on Small Business There are at least 47 firms currently known to be marketing hand- held...

  3. The Weak Link HP-41C hand-held calculator program

    Science.gov (United States)

    Ross A. Phillips; Penn A. Peters; Gary D. Falk

    1982-01-01

    The Weak Link hand-held calculator program (HP-41C) quickly analyzes a system for logging production and costs. The production equations model conventional chain saw, skidder, loader, and tandemaxle truck operations in eastern mountain areas. Production of each function of the logging system may be determined so that the system may be balanced for minimum cost. The...

  4. Preliminary results of a gamma-ray burst study in the Konus experiment on the Venera-11 and Venera-12 space probes

    International Nuclear Information System (INIS)

    Mazets, Y.P.; Golentskii, S.V.; Ilinskii, V.N.; Panov, V.N.; Aptekar, R.L.

    Twenty-one gamma-ray bursts and 68 solar flares in the hard X-ray range were detected on Venera-11 and Venera-12 space probes during the initial 50-day observation period. Major characteristics of the equipment used and preliminary data on the temporal structure and energy spectra of the gamma-ray bursts are considered. The pattern of gamma-ray burst frequency distribution vs. intensity, N(S), is established

  5. Flux-focusing eddy current probe and rotating probe method for flaw detection

    Science.gov (United States)

    Wincheski, Buzz A.; Fulton, James P.; Nath, Shridhar C.; Simpson, John W.; Namkung, Min

    1994-11-01

    A flux-focusing electromagnetic sensor which uses a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks about circular fasteners and other circular inhomogeneities in high conductivity material. The unique feature of the device is the ferrous shield isolating a high-turn pick-up coil from an excitation coil. The use of the magnetic shield is shown to produce a null voltage output across the receiving coil in the presence of an unflawed sample. A redistribution of the current flow in the sample caused by the presence of flaws, however, eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. By rotating the probe in a path around a circular fastener such as a rivet while maintaining a constant distance between the probe and the center of a rivet, the signal due to current flow about the rivet can be held constant. Any further changes in the current distribution, such as due to a fatigue crack at the rivet joint, can be detected as an increase in the output voltage above that due to the flow about the rivet head.

  6. Sensitivity of self-powered detector probes to electron and gamma-ray fields

    Energy Technology Data Exchange (ETDEWEB)

    Lone, M A; Wong, P Y [Atomic Energy of Canada Ltd., Chalk River, ON (Canada)

    1996-12-31

    A self-powered detector (SPD) is a simple, passive device that consists of a coaxial probe with a metallic outer sleeve, a mineral oxide insulating layer, and a metallic inner core. SPD`s are used in nuclear reactors to monitor neutron and gamma fields. Responses of SPD`s to electrons and {gamma}-rays of various energies were investigated with Monte Carlo simulations. Transmission filters were studied for the design of threshold SPD probes used for online monitoring of the energy spectrum of high-power industrial electron accelerator beams. Filters were also investigated for the enhancement of {gamma}-ray sensitivity of an SPD placed in a mixed electron and {gamma}-ray field. (author). 30 refs., 1 tab., 8 figs.

  7. Automation of the monitoring in real time of the absorbed dose rate in air due to the environmental gamma radiation in Cuba; Automatizacion del monitoreo en tiempo real de la tasa de dosis absorbida en aire debido a la radiacion gamma ambiental en Cuba

    Energy Technology Data Exchange (ETDEWEB)

    Dominguez L, O; Capote F, E; Carrazana G, J A; Manzano de Armas, J F; Alonso A, D; Prendes A, M; Zerquera, J T; Caveda R, C A [CPHR, Calle 20, No. 4113 e/41 y 47, Playa, La Habana, 11300, A.P. 6195 C.P. 10600 (Cuba); Kalberg, O [Swedish Radiation Protection Institute (SSI) (Sweden); Fabelo B, O; Montalvan E, A [CIAC, Camaguey (Cuba); Cartas A, H [CEAC, Cienfuegos (Cuba); Leyva F, J C [CISAT (Cuba)

    2006-07-01

    The Center of Protection and Hygiene of the Radiations (CPHR) like center rector of the National Net of Environmental Radiological Surveillance (RNVRA), it has strengthened their detection capacity and of answer before a situation of radiological emergency. The measurements of the absorbed dose rate in air due to the environmental gamma radiation in the main stations of the Net are obtained in real time and the CPHR receives the data coming from these posts at one time relatively short. To improve the operability of the RNVRA it was necessary to complete the facilities of existent monitoring using 4 automatic measurement stations with probes of gamma detection, implementing in this way a measurement system on real time. On the other hand the software were developed: GenironProbeFech, to obtain the data of the probes, DataMail for the shipment of the same ones by electronic mail and GammaRed that receives and processes the data in the rector center. (Author)

  8. A hand-held sensor for analyses of local distributions of magnetic fields and losses

    CERN Document Server

    Krismanic, G; Baumgartinger, N

    2000-01-01

    The paper describes a novel sensor for non-destructive analyses of local field and loss distributions in laminated soft magnetic cores, such as transformer cores. It was designed for rapid information on comparative local degrees of inhomogeneity, e.g., for the estimation of local building factors. Similar to a magnifying glass with handle, the compact hand-held sensor contains extremely sharp needle electrodes for the detection of the induction vector B as well as double-field coils for the vector H. Losses P are derived from the Poynting law. Applied to inner -- or also outer -- core regions, the sensor yields instantaneous computer displays of local H, B, and P.

  9. Hand-held hyperspectral imager for chemical/biological and environmental applications

    Science.gov (United States)

    Hinnrichs, Michele; Piatek, Bob

    2004-03-01

    A small, hand held, battery operated imaging infrared spectrometer, Sherlock, has been developed by Pacific Advanced Technology and was field tested in early 2003. The Sherlock spectral imaging camera has been designed for remote gas leak detection, however, the architecture of the camera is versatile enough that it can be applied to numerous other applications such as homeland security, chemical/biological agent detection, medical and pharmaceutical applications as well as standard research and development. This paper describes the Sherlock camera, theory of operations, shows current applications and touches on potential future applications for the camera. The Sherlock has an embedded Power PC and performs real-time-image processing function in an embedded FPGA. The camera has a built in LCD display as well as output to a standard monitor, or NTSC display. It has several I/O ports, ethernet, firewire, RS232 and thus can be easily controlled from a remote location. In addition, software upgrades can be performed over the ethernet eliminating the need to send the camera back to the factory for a retrofit. Using the USB port a mouse and key board can be connected and the camera can be used in a laboratory environment as a stand alone imaging spectrometer.

  10. DETECTION OF DRUGSTORE BEETLES IN 9975 PACKAGES USING ACOUSTIC EMISSIONS

    Energy Technology Data Exchange (ETDEWEB)

    Shull, D.

    2013-03-04

    This report documents the initial feasibility tests performed using a commercial acoustic emission instrument for the purpose of detecting beetles in Department of Energy 9975 shipping packages. The device selected for this testing was a commercial handheld instrument and probe developed for the detection of termites, weevils, beetles and other insect infestations in wooden structures, trees, plants and soil. The results of two rounds of testing are presented. The first tests were performed by the vendor using only the hand-held instrument’s indications and real-time operator analysis of the audio signal content. The second tests included hands-free positioning of the instrument probe and post-collection analysis of the recorded audio signal content including audio background comparisons. The test results indicate that the system is promising for detecting the presence of drugstore beetles, however, additional work would be needed to improve the ease of detection and to automate the signal processing to eliminate the need for human interpretation. Mechanisms for hands-free positioning of the probe and audio background discrimination are also necessary for reliable detection and to reduce potential operator dose in radiation environments.

  11. Automation of the monitoring in real time of the absorbed dose rate in air due to the environmental gamma radiation in Cuba

    International Nuclear Information System (INIS)

    Dominguez L, O.; Capote F, E.; Carrazana G, J.A.; Manzano de Armas, J.F.; Alonso A, D.; Prendes A, M.; Zerquera, J.T.; Caveda R, C.A.; Kalberg, O.; Fabelo B, O.; Montalvan E, A.; Cartas A, H.; Leyva F, J.C.

    2006-01-01

    The Center of Protection and Hygiene of the Radiations (CPHR) like center rector of the National Net of Environmental Radiological Surveillance (RNVRA), it has strengthened their detection capacity and of answer before a situation of radiological emergency. The measurements of the absorbed dose rate in air due to the environmental gamma radiation in the main stations of the Net are obtained in real time and the CPHR receives the data coming from these posts at one time relatively short. To improve the operability of the RNVRA it was necessary to complete the facilities of existent monitoring using 4 automatic measurement stations with probes of gamma detection, implementing in this way a measurement system on real time. On the other hand the software were developed: GenironProbeFech, to obtain the data of the probes, DataMail for the shipment of the same ones by electronic mail and GammaRed that receives and processes the data in the rector center. (Author)

  12. Hand-held transendoscopic robotic manipulators: A transurethral laser prostate surgery case study.

    Science.gov (United States)

    Hendrick, Richard J; Mitchell, Christopher R; Herrell, S Duke; Webster, Robert J

    2015-11-01

    Natural orifice endoscopic surgery can enable incisionless approaches, but a major challenge is the lack of small and dexterous instrumentation. Surgical robots have the potential to meet this need yet often disrupt the clinical workflow. Hand-held robots that combine thin manipulators and endoscopes have the potential to address this by integrating seamlessly into the clinical workflow and enhancing dexterity. As a case study illustrating the potential of this approach, we describe a hand-held robotic system that passes two concentric tube manipulators through a 5 mm port in a rigid endoscope for transurethral laser prostate surgery. This system is intended to catalyze the use of a clinically superior, yet rarely attempted, procedure for benign prostatic hyperplasia. This paper describes system design and experiments to evaluate the surgeon's functional workspace and accuracy using the robot. Phantom and cadaver experiments demonstrate successful completion of the target procedure via prostate lobe resection.

  13. Hand held lasers, a hazard to aircraft: How do we address this?

    Science.gov (United States)

    Barat, K.

    2015-10-01

    The availability of hand held lasers, commonly termed "laser pointers" is easy and wide spread, through commercial web sites and brick & mortar stores. The output of these hand held devices ranges from 1-5 milliWatts (mW) the legal laser pointer output limit, to 5000mW (5Watts). This is thousand times the maximum limit for pointers. Sadly the abuse of these devices is also wide spread. Over the last few years over 3000 aircraft are exposed to laser hits per year. While these aircraft exposures are of no danger to the aircraft frame but they can cause pilot distractions with the potential to cause a serve accident. The presentation will discuss the problem review visual effects, the regulatory response and how educators need to be aware of the problem and can take steps to educate students in the hope of having an effect.

  14. Four dimensional hybrid ultrasound and optoacoustic imaging via passive element optical excitation in a hand-held probe

    Science.gov (United States)

    Fehm, Thomas Felix; Deán-Ben, Xosé Luís; Razansky, Daniel

    2014-10-01

    Ultrasonography and optoacoustic imaging share powerful advantages related to the natural aptitude for real-time image rendering with high resolution, the hand-held operation, and lack of ionizing radiation. The two methods also possess very different yet highly complementary advantages of the mechanical and optical contrast in living tissues. Nonetheless, efficient integration of these modalities remains challenging owing to the fundamental differences in the underlying physical contrast, optimal signal acquisition, and image reconstruction approaches. We report on a method for hybrid acquisition and reconstruction of three-dimensional pulse-echo ultrasound and optoacoustic images in real time based on passive ultrasound generation with an optical absorber, thus avoiding the hardware complexity of active ultrasound generation. In this way, complete hybrid datasets are generated with a single laser interrogation pulse, resulting in simultaneous rendering of ultrasound and optoacoustic images at an unprecedented rate of 10 volumetric frames per second. Performance is subsequently showcased in phantom experiments and in-vivo measurements from a healthy human volunteer, confirming general clinical applicability of the method.

  15. Four dimensional hybrid ultrasound and optoacoustic imaging via passive element optical excitation in a hand-held probe

    International Nuclear Information System (INIS)

    Fehm, Thomas Felix; Razansky, Daniel; Deán-Ben, Xosé Luís

    2014-01-01

    Ultrasonography and optoacoustic imaging share powerful advantages related to the natural aptitude for real-time image rendering with high resolution, the hand-held operation, and lack of ionizing radiation. The two methods also possess very different yet highly complementary advantages of the mechanical and optical contrast in living tissues. Nonetheless, efficient integration of these modalities remains challenging owing to the fundamental differences in the underlying physical contrast, optimal signal acquisition, and image reconstruction approaches. We report on a method for hybrid acquisition and reconstruction of three-dimensional pulse-echo ultrasound and optoacoustic images in real time based on passive ultrasound generation with an optical absorber, thus avoiding the hardware complexity of active ultrasound generation. In this way, complete hybrid datasets are generated with a single laser interrogation pulse, resulting in simultaneous rendering of ultrasound and optoacoustic images at an unprecedented rate of 10 volumetric frames per second. Performance is subsequently showcased in phantom experiments and in-vivo measurements from a healthy human volunteer, confirming general clinical applicability of the method.

  16. Four dimensional hybrid ultrasound and optoacoustic imaging via passive element optical excitation in a hand-held probe

    Energy Technology Data Exchange (ETDEWEB)

    Fehm, Thomas Felix; Razansky, Daniel, E-mail: dr@tum.de [Institute for Biological and Medical Imaging (IBMI), Helmholtz Zentrum München, Neuherberg (Germany); Faculty of Medicine, Technische Universität München, Munich (Germany); Deán-Ben, Xosé Luís [Institute for Biological and Medical Imaging (IBMI), Helmholtz Zentrum München, Neuherberg (Germany)

    2014-10-27

    Ultrasonography and optoacoustic imaging share powerful advantages related to the natural aptitude for real-time image rendering with high resolution, the hand-held operation, and lack of ionizing radiation. The two methods also possess very different yet highly complementary advantages of the mechanical and optical contrast in living tissues. Nonetheless, efficient integration of these modalities remains challenging owing to the fundamental differences in the underlying physical contrast, optimal signal acquisition, and image reconstruction approaches. We report on a method for hybrid acquisition and reconstruction of three-dimensional pulse-echo ultrasound and optoacoustic images in real time based on passive ultrasound generation with an optical absorber, thus avoiding the hardware complexity of active ultrasound generation. In this way, complete hybrid datasets are generated with a single laser interrogation pulse, resulting in simultaneous rendering of ultrasound and optoacoustic images at an unprecedented rate of 10 volumetric frames per second. Performance is subsequently showcased in phantom experiments and in-vivo measurements from a healthy human volunteer, confirming general clinical applicability of the method.

  17. The reliability and validity of hand-held refractometry water content measures of hydrogel lenses.

    Science.gov (United States)

    Nichols, Jason J; Mitchell, G Lynn; Good, Gregory W

    2003-06-01

    To investigate within- and between-examiner reliability and validity of hand-held refractometry water content measures of hydrogel lenses. Nineteen lenses of various nominal water contents were examined by two examiners on two occasions separated by 1 hour. An Atago N2 hand-held refractometer was used for all water content measures. Lenses were presented in a random order to each examiner by a third party, and examiners were masked to any potential lens identifiers. Intraclass correlation coefficients (ICC), 95% limits of agreement, and Wilcoxon signed rank test were used to characterize the within- and between-examiner reliability and validity of lens water content measures. Within-examiner reliability was excellent (ICC, 0.97; 95% limits of agreement, -3.6% to +5.7%), and the inter-visit mean difference of 1.1 +/- 2.4% was not biased (p = 0.08). Between-examiner reliability was also excellent (ICC, 0.98; 95% limits of agreement, -4.1% to +3.9%). The mean difference between examiners was -0.1 +/- 2.1% (p = 0.83). The mean difference between the nominally reported water content and our water content measures was -2.1 +/- 1.7% (p refractometry and is material dependent. Therefore, investigators may need to account for bias when measuring hydrogel lens water content via hand-held refractometry.

  18. Balancing fast-rotating parts of hand-held machine drive

    Science.gov (United States)

    Korotkov, V. S.; Sicora, E. A.; Nadeina, L. V.; Yongzheng, Wang

    2018-03-01

    The article considers the issues related to the balancing of fast rotating parts of the hand-held machine drive including a wave transmission with intermediate rolling elements, which is constructed on the basis of the single-phase collector motor with a useful power of 1 kW and a nominal rotation frequency of 15000 rpm. The forms of balancers and their location are chosen. The method of balancing is described. The scheme for determining of residual unbalance in two correction planes is presented. Measurement results are given in tables.

  19. USE OF PORTABLE GAMMA SPECTROMETERS FOR IDENTIFYING PERSONS EXPOSED IN A NUCLEAR CRITICALITY

    Energy Technology Data Exchange (ETDEWEB)

    Veinot, K. G. [Y-12 National Security Complex; Gose, B. T. [Y-12 National Security Complex; Bogard, James S [ORNL

    2009-01-01

    At Y-12 triage-style assessments are used to identify persons potentially exposed to high doses from criticality accident radiations using portable instruments by assessing the presence of activated sodium atoms in a person's blood. Historically, simple hand-held Geiger-Mueller (G-M) probes were used for these purposes although it was recognized that, since these instruments contain no information on incident photon energy, it was impossible to differentiate between photons emitted by contamination on the potentially exposed worker from activation of sodium in the person s blood. This works examines the use of a portable gamma spectrometer for assessing blood sodium activation. Irradiations of a representative phantom were performed using two neutron source configurations (unmoderated and polyethylene-moderated 252Cf) and measurements were made using the spectrometer and a G-M detector following irradiation. Detection limits in terms of personnel neutron dose are given for two neutron fields representing metaland solution criticality spectra. Both Geiger-Mueller and spectrometer results indicate a low minimum detectable neutron dose indicating that both instrument are useful as an emergency response instrument. The spectrometer has the added benefit of discriminating between surface contamination and blood sodium activation.

  20. USE OF PORTABLE GAMMA SPECTROMETERS FOR IDENTIFYING PERSONS EXPOSED IN A NUCLEAR CRITICALITY

    International Nuclear Information System (INIS)

    Veinot, K.G.; Gose, B.T.; Bogard, James S.

    2009-01-01

    At Y-12 triage-style assessments are used to identify persons potentially exposed to high doses from criticality accident radiations using portable instruments by assessing the presence of activated sodium atoms in a person's blood. Historically, simple hand-held Geiger-Mueller (G-M) probes were used for these purposes although it was recognized that, since these instruments contain no information on incident photon energy, it was impossible to differentiate between photons emitted by contamination on the potentially exposed worker from activation of sodium in the persons blood. This works examines the use of a portable gamma spectrometer for assessing blood sodium activation. Irradiations of a representative phantom were performed using two neutron source configurations (unmoderated and polyethylene-moderated 252Cf) and measurements were made using the spectrometer and a G-M detector following irradiation. Detection limits in terms of personnel neutron dose are given for two neutron fields representing metal and solution criticality spectra. Both Geiger-Mueller and spectrometer results indicate a low minimum detectable neutron dose indicating that both instrument are useful as an emergency response instrument. The spectrometer has the added benefit of discriminating between surface contamination and blood sodium activation.

  1. Radiation safety evaluation of a hand-held, battery operated image intensifier

    International Nuclear Information System (INIS)

    Wilson, O.J.; Young, B.F.

    1987-01-01

    A portable, hand-held, fluoroscopic unit intended for medical and industrial use was tested to verify the claim of the manufacturers that the radiation doses to the patient and user are low, and comparable to those received from standard radiographic procedures. The first claim was substantiated but not the second. A number of concerns arising from the use of this unit are discussed

  2. Comparative Geometrical Accuracy Investigations of Hand-Held 3d Scanning Systems - AN Update

    Science.gov (United States)

    Kersten, T. P.; Lindstaedt, M.; Starosta, D.

    2018-05-01

    Hand-held 3D scanning systems are increasingly available on the market from several system manufacturers. These systems are deployed for 3D recording of objects with different size in diverse applications, such as industrial reverse engineering, and documentation of museum exhibits etc. Typical measurement distances range from 0.5 m to 4.5 m. Although they are often easy-to-use, the geometric performance of these systems, especially the precision and accuracy, are not well known to many users. First geometrical investigations of a variety of diverse hand-held 3D scanning systems were already carried out by the Photogrammetry & Laser Scanning Lab of the HafenCity University Hamburg (HCU Hamburg) in cooperation with two other universities in 2016. To obtain more information about the accuracy behaviour of the latest generation of hand-held 3D scanning systems, HCU Hamburg conducted further comparative geometrical investigations using structured light systems with speckle pattern (Artec Spider, Mantis Vision PocketScan 3D, Mantis Vision F5-SR, Mantis Vision F5-B, and Mantis Vision F6), and photogrammetric systems (Creaform HandySCAN 700 and Shining FreeScan X7). In the framework of these comparative investigations geometrically stable reference bodies were used. The appropriate reference data was acquired by measurements with two structured light projection systems (AICON smartSCAN and GOM ATOS I 2M). The comprehensive test results of the different test scenarios are presented and critically discussed in this contribution.

  3. GammaWorkshops Proceedings

    International Nuclear Information System (INIS)

    Ramebaeck, H.; Straelberg, E.; Klemola, S.; Nielsen, Sven P.; Palsson, S.E.

    2012-01-01

    Due to a sparse interaction during the last years between practioners in gamma ray spectrometry in the Nordic countries, a NKS activity was started in 2009. This GammaSem was focused on seminars relevant to gamma spectrometry. A follow up seminar was held in 2010. As an outcome of these activities it was suggested that the 2011 meeting should be focused on practical issues, e.g. different corrections needed in gamma spectrometric measurements. This three day's meeting, GammaWorkshops, was held in September at Risoe-DTU. Experts on different topics relevant for gamma spectrometric measurements were invited to the GammaWorkshops. The topics included efficiency transfer, true coincidence summing corrections, self-attenuation corrections, measurement of natural radionuclides (natural decay series), combined measurement uncertainty calculations, and detection limits. These topics covered both lectures and practical sessions. The practical sessions included demonstrations of tools for e.g. corrections and calculations of the above meantioned topics. (Author)

  4. GammaWorkshops Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Ramebaeck, H. (ed.) (Swedish Defence Research Agency (Sweden)); Straalberg, E. (Institute for Energy Technology, Kjeller (Norway)); Klemola, S. (Radiation and Nuclear Safety Authority, STUK (Finland)); Nielsen, Sven P. (Technical Univ. of Denmark. Risoe National Lab. for Sustainable Energy, Roskilde (Denmark)); Palsson, S.E. (Icelandic Radiation Safety Authority (Iceland))

    2012-01-15

    Due to a sparse interaction during the last years between practioners in gamma ray spectrometry in the Nordic countries, a NKS activity was started in 2009. This GammaSem was focused on seminars relevant to gamma spectrometry. A follow up seminar was held in 2010. As an outcome of these activities it was suggested that the 2011 meeting should be focused on practical issues, e.g. different corrections needed in gamma spectrometric measurements. This three day's meeting, GammaWorkshops, was held in September at Risoe-DTU. Experts on different topics relevant for gamma spectrometric measurements were invited to the GammaWorkshops. The topics included efficiency transfer, true coincidence summing corrections, self-attenuation corrections, measurement of natural radionuclides (natural decay series), combined measurement uncertainty calculations, and detection limits. These topics covered both lectures and practical sessions. The practical sessions included demonstrations of tools for e.g. corrections and calculations of the above meantioned topics. (Author)

  5. Neutron detection gamma ray sensitivity criteria

    International Nuclear Information System (INIS)

    Kouzes, Richard T.; Ely, James H.; Lintereur, Azaree T.; Mace, Emily K.; Stephens, Daniel L.; Woodring, Mitchell L.

    2011-01-01

    The shortage of 3 He has triggered the search for effective alternative neutron detection technologies for national security and safeguards applications. Any new detection technology must satisfy two basic criteria: (1) it must meet a neutron detection efficiency requirement, and (2) it must be insensitive to gamma-ray interference at a prescribed level, while still meeting the neutron detection requirement. It is the purpose of this paper to define measureable gamma ray sensitivity criteria for neutron detectors. Quantitative requirements are specified for: intrinsic gamma ray detection efficiency and gamma ray absolute rejection. The gamma absolute rejection ratio for neutrons (GARRn) is defined, and it is proposed that the requirement for neutron detection be 0.9 3 He based neutron detector is provided showing that this technology can meet the stated requirements. Results from tests of some alternative technologies are also reported.

  6. Development of an aptamer beacon for detection of interferon-gamma.

    Science.gov (United States)

    Tuleuova, Nazgul; Jones, Caroline N; Yan, Jun; Ramanculov, Erlan; Yokobayashi, Yohei; Revzin, Alexander

    2010-03-01

    Traditional antibody-based affinity sensing strategies employ multiple reagents and washing steps and are unsuitable for real-time detection of analyte binding. Aptamers, on the other hand, may be designed to monitor binding events directly, in real-time, without the need for secondary labels. The goal of the present study was to design an aptamer beacon for fluorescence resonance energy transfer (FRET)-based detection of interferon-gamma (IFN-gamma)--an important inflammatory cytokine. Variants of DNA aptamer modified with biotin moieties and spacers were immobilized on avidin-coated surfaces and characterized by surface plasmon resonance (SPR). The SPR studies showed that immobilization of aptamer via the 3' end resulted in the best binding IFN-gamma (K(d) = 3.44 nM). This optimal aptamer variant was then used to construct a beacon by hybridizing fluorophore-labeled aptamer with an antisense oligonucleotide strand carrying a quencher. SPR studies revealed that IFN-gamma binding with an aptamer beacon occurred within 15 min of analyte introduction--suggesting dynamic replacement of the quencher-complementary strand by IFN-gamma molecules. To further highlight biosensing applications, aptamer beacon molecules were immobilized inside microfluidic channels and challenged with varying concentration of analyte. Fluorescence microscopy revealed low fluorescence in the absence of analyte and high fluorescence after introduction of IFN-gamma. Importantly, unlike traditional antibody-based immunoassays, the signal was observed directly upon binding of analyte without the need for multiple washing steps. The surface immobilized aptamer beacon had a linear range from 5 to 100 nM and a lower limit of detection of 5 nM IFN-gamma. In conclusion, we designed a FRET-based aptamer beacon for monitoring of an inflammatory cytokine-IFN-gamma. In the future, this biosensing strategy will be employed to monitor dynamics of cytokine production by the immune cells.

  7. A Comparison Of GADRAS Simulated And Measured Gamma Ray Spectra

    International Nuclear Information System (INIS)

    Jeffcoat, R.; Salaymeh, S.

    2010-01-01

    Gamma-ray radiation detection systems are continuously being developed and improved for detecting the presence of radioactive material and for identifying isotopes present. Gamma-ray spectra, from many different isotopes and in different types and thicknesses of attenuation material and matrixes, are needed to evaluate the performance of these devices. Recently, a test and evaluation exercise was performed by the Savannah River National Laboratory that required a large number of gamma-ray spectra. Simulated spectra were used for a major portion of the testing in order to provide a pool of data large enough for the results to be statistically significant. The test data set was comprised of two types of data, measured and simulated. The measured data were acquired with a hand-held Radioisotope Identification Device (RIID) and simulated spectra were created using Gamma Detector Response and Analysis Software (GADRAS, Mitchell and Mattingly, Sandia National Laboratory). GADRAS uses a one-dimensional discrete ordinate calculation to simulate gamma-ray spectra. The measured and simulated spectra have been analyzed and compared. This paper will discuss the results of the comparison and offer explanations for spectral differences.

  8. Integrating a Hand Held computer and Stethoscope into a Fetal Monitor

    Science.gov (United States)

    Ahmad Soltani, Mitra

    2009-01-01

    This article presents procedures for modifying a hand held computer or personal digital assistant (PDA) into a versatile device functioning as an electronic stethoscope for fetal monitoring. Along with functioning as an electronic stethoscope, a PDA can provide a useful information source for a medical trainee. Feedback from medical students, residents and interns suggests the device is well accepted by medical trainees. PMID:20165517

  9. A new method for intraoperative localization of epilepsy focus by means of a gamma probe; Um novo metodo para a localizacao intraoperatoria de foco de epilepsia mediante utilizacao de gamaprobe

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro Filho, Omar, E-mail: dromarcarneiro@gmail.com [Centro Brasileiro de Medicina Nuclear e Imagem Molecular (CEBRAMEN), Goiania, GO (Brazil); Instituto de Medicina Nuclear, Goiania, GO (Brazil); Vilela Filho, Osvaldo [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Hospital das Clinicas. Servico de Neurocirurgia; Ragazzo, Paulo Cesar [Instituto de Neurologia de Goiania, GO (Brazil). Servico de Eplepsia e Neurofisiologia; Fonseca, Lea Mirian Barbosa da [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Dept. de Radiologia

    2014-01-15

    Objective: to evaluate the utility of a new multimodal image-guided intervention technique to detect epileptogenic areas with a gamma probe as compared with intraoperative electrocorticography. Materials and methods: two symptomatic patients with refractory epilepsy underwent magnetic resonance imaging, videoelectroencephalography, brain SPECT scan, neuropsychological evaluation and were submitted to gamma probe-assisted surgery. Results: in patient 1, maximum radioactive count was initially observed on the temporal gyrus at about 3.5 cm posteriorly to the tip of the left temporal lobe. After corticotomy, the gamma probe indicated maximum count at the head of the hippocampus, in agreement with the findings of intraoperative electrocorticography. In patient 2, maximum count was observed in the occipital region at the transition between the temporal and parietal lobes (right hemisphere). During the surgery, the area of epileptogenic activity mapped at electrocorticography was also delimited, demarcated, and compared with the gamma probe findings. After lesionectomy, new radioactive counts were performed both in the patients and on the surgical specimens (ex-vivo). Conclusion: the comparison between intraoperative electrocorticography and gamma probe-assisted surgery showed similarity of both methods. The advantages of gamma probe include: noninvasiveness, low cost and capacity to demonstrate decrease in the radioactive activity at the site of excision after lesionectomy. (author)

  10. Fixed-wing gamma measurement for the detection of radioactive materials

    International Nuclear Information System (INIS)

    Kettunen, M.J.; Nikkinen, M.T.

    2005-01-01

    Finland has the operational capability to take airborne gamma-ray measurements in emergency situations. The original purpose of airborne radiation mapping in Finland was to identify hazardous areas containing radioactive fall-out after a nuclear accident or use of nuclear weapons. Regular exercises are held annually to keep the operational functionality at a high level. The achieved capability has been well demonstrated in international INEX-2-FIN 1997 and Barents Rescue 2001 exercises. The knowledge and competence achieved can easily be applied in international radiation monitoring campaigns designed to expose undeclared nuclear materials or other clandestine nuclear activities. The essential improvements in the detection system are linked to the ability to locate point-like radiation sources rather than large areas of fall-out. Aerial gamma-ray measurement method and its usability for the detection of nuclear material production chains and trails of fission or activation products is described. The ability of airborne detection systems in revealing the use of undeclared nuclear materials has been tested. Various scenarios for exposing clandestine nuclear material production, enrichment and nuclear waste trails have been considered. Based on detection capability calculations and testing in practice, it was found that the detection of one un-shielded significant quantity of natural uranium (10 tons of yellow cake in storage barrels) is possible through the daughter products, using one single 6' x 4' NaI detector on the airplane. The developed fixed wing gamma measurement technique is now able to detect significant amounts of nuclear material conveniently and cost-effectively. Large areas can be screened to identify suspicious sub-areas for more detailed ground-based inspection. (author)

  11. System for gamma-gamma formation density logging while drilling

    International Nuclear Information System (INIS)

    Paske, W.C.

    1991-01-01

    The patent relates to a system for logging subterranean formations for the determination of formation density by using gamma radiation. Gamma ray source and detection means are disposed within a housing adapted for positioning within a borehole for the emission and detection of gamma rays propagating through earth formations and borehole drilling fluid. The gamma ray detection means comprises first and second gamma radiation sensors geometrically disposed within the housing, the same longitudinal distance from the gamma ray source and diametrically opposed in a common plane. A formation matrix density output signal is produced in proportion to the output signal from each of the gamma ray sensors and in conjunction with certain constants established by the geometrical configuration of the sensors relative to the gamma ray source and the borehole diameter. Formation density is determined without regard to the radial position of the logging probe within the borehole in a measuring while drilling mode. 6 figs

  12. Measurement of gastric emptying rate in humans. Simplified scanning method

    Energy Technology Data Exchange (ETDEWEB)

    Holt, S.; Colliver, J.; Guram, M.; Neal, C.; Verhulst, S.J.; Taylor, T.V. (Univ. of South Carolina School of Medicine, Columbia (USA))

    1990-11-01

    Simultaneous measurements of the gastric emptying rate of the solid and liquid phase of a dual-isotope-labeled test meal were made using a gamma camera and a simple scintillation detector, similar to that used in a hand-held probe. A simple scanning apparatus, similar to that used in a hand-held scintillation probe, was compared with simultaneous measurements made by a gamma camera in 16 healthy males. A dual-labeled test meal was utilized to measure liquid and solid emptying simultaneously. Anterior and posterior scans were taken at intervals up to 120 min using both a gamma camera and the scintillation probe. Good relative agreement between the methods was obtained both for solid-phase (correlation range 0.92-0.99, mean 0.97) and for liquid-phase data (correlation range 0.93-0.99, mean 0.97). For solid emptying data regression line slopes varied from 0.75 to 1.03 (mean 0.84). Liquid emptying data indicated that slopes ranged from 0.71 to 1.06 (mean 0.87). These results suggested that an estimate of the gamma measurement could be obtained by multiplying the scintillation measurement by a factor of 0.84 for the solid phase and 0.87 for the liquid phase. Correlation between repeat studies was 0.97 and 0.96 for solids and liquids, respectively. The application of a hand-held probe technique provides a noninvasive and inexpensive method for accurately assessing solid- and liquid-phase gastric emptying from the human stomach that correlates well with the use of a gamma camera, within the range of gastric emptying rate in the normal individuals in this study.

  13. Measurement of gastric emptying rate in humans. Simplified scanning method

    International Nuclear Information System (INIS)

    Holt, S.; Colliver, J.; Guram, M.; Neal, C.; Verhulst, S.J.; Taylor, T.V.

    1990-01-01

    Simultaneous measurements of the gastric emptying rate of the solid and liquid phase of a dual-isotope-labeled test meal were made using a gamma camera and a simple scintillation detector, similar to that used in a hand-held probe. A simple scanning apparatus, similar to that used in a hand-held scintillation probe, was compared with simultaneous measurements made by a gamma camera in 16 healthy males. A dual-labeled test meal was utilized to measure liquid and solid emptying simultaneously. Anterior and posterior scans were taken at intervals up to 120 min using both a gamma camera and the scintillation probe. Good relative agreement between the methods was obtained both for solid-phase (correlation range 0.92-0.99, mean 0.97) and for liquid-phase data (correlation range 0.93-0.99, mean 0.97). For solid emptying data regression line slopes varied from 0.75 to 1.03 (mean 0.84). Liquid emptying data indicated that slopes ranged from 0.71 to 1.06 (mean 0.87). These results suggested that an estimate of the gamma measurement could be obtained by multiplying the scintillation measurement by a factor of 0.84 for the solid phase and 0.87 for the liquid phase. Correlation between repeat studies was 0.97 and 0.96 for solids and liquids, respectively. The application of a hand-held probe technique provides a noninvasive and inexpensive method for accurately assessing solid- and liquid-phase gastric emptying from the human stomach that correlates well with the use of a gamma camera, within the range of gastric emptying rate in the normal individuals in this study

  14. Multiscale Convolutional Neural Networks for Hand Detection

    Directory of Open Access Journals (Sweden)

    Shiyang Yan

    2017-01-01

    Full Text Available Unconstrained hand detection in still images plays an important role in many hand-related vision problems, for example, hand tracking, gesture analysis, human action recognition and human-machine interaction, and sign language recognition. Although hand detection has been extensively studied for decades, it is still a challenging task with many problems to be tackled. The contributing factors for this complexity include heavy occlusion, low resolution, varying illumination conditions, different hand gestures, and the complex interactions between hands and objects or other hands. In this paper, we propose a multiscale deep learning model for unconstrained hand detection in still images. Deep learning models, and deep convolutional neural networks (CNNs in particular, have achieved state-of-the-art performances in many vision benchmarks. Developed from the region-based CNN (R-CNN model, we propose a hand detection scheme based on candidate regions generated by a generic region proposal algorithm, followed by multiscale information fusion from the popular VGG16 model. Two benchmark datasets were applied to validate the proposed method, namely, the Oxford Hand Detection Dataset and the VIVA Hand Detection Challenge. We achieved state-of-the-art results on the Oxford Hand Detection Dataset and had satisfactory performance in the VIVA Hand Detection Challenge.

  15. Gamma-ray identification of nuclear weapon materials

    International Nuclear Information System (INIS)

    Gosnell, T. B.; Hall, J. M.; Jam, C. L.; Knapp, D. A.; Koenig, Z. M.; Luke, S. J.; Pohl, B. A.; Schach Wittenau, A. von; Wolford, J. K.

    1997-01-01

    There has been an accelerating national interest in countering nuclear smuggling. This has caused a corresponding expansion of interest in the use of gamma-ray spectrometers for checkpoint monitoring, nuclear search, and within networks of nuclear and collateral sensors. All of these are fieldable instruments--ranging from large, fixed portal monitors to hand-held and remote monitoring equipment. For operational reasons, detectors with widely varying energy resolution and detection efficiency will be employed. In many instances, such instruments must be sensitive to weak signals, always capable of recognizing the gamma-ray signatures from nuclear weapons materials (NWM), often largely insensitive to spectral alteration by radiation transport through intervening materials, capable of real-time implementation, and able to discriminate against signals from commonly encountered legitimate gamma-ray sources, such as radiopharmaceuticals. Several decades of experience in classified programs have shown that all of these properties are not easily achieved and successful approaches were of limited scope--such as the detection of plutonium only. This project was originally planned as a two-year LDRD-ER. Since funding for 1997 was not sustained, this is a report of the first year's progress

  16. Sentinel node localisation using pre-operative lymphoscintigraphy and intraoperative gamma probe in early oral cavity cancer

    International Nuclear Information System (INIS)

    Ikram, M.; Akhtar, S.; Junaid, M.; Dhari, T.; Zaman, M.U.; Hussain, R.

    2013-01-01

    Objectives: To assess the diagnostic value of sentinel lymph node localisation using pre-operative lymphoscintigraphy and intra-operative gamma probe radio localisation in Pakistani patients suffering from early stage squamous cell carcinoma of the oral cavity. Methods: The prospective case series was conducted between September 2007 and April 2010 at the Aga Khan University Hospital, Karachi. It comprised patients with T1 and T2 oral cavity cancer with clinically and radiologically negative neck. Pre-operative lymphoscintigraphy was performed one day before surgery and intra-operative gamma probe was used to detect sentinel node. Final histo-pathological evaluation was taken as the gold standard. Results: The study comprised 42 patients: 32(76%) males and 10(24%) females. The primary tumour site was buccal mucosa in 25 (60%) patients, and tongue in 17 (40%). Sentinel lymph node was detected in 38 (90%) patients. On final histopathological identification, 7 (17%) patients had cancer in the neck nodes. In all patients with metastasis, sentinel lymph node technique correctly identified the involved neck level. None of the patients revealed metastasis in non-sentinel lymph nodes. Conclusion:Evidence suggested the use of sentinel node biopsy in patients with head and neck squamous cell carcinoma. (author)

  17. Performance evaluation of a hand-held, semiconductor (CdZnTe)-based gamma camera

    CERN Document Server

    Abe, A; Lee, J; Oka, T; Shizukuishi, K; Kikuchi, T; Inoue, T; Jimbo, M; Ryuo, H; Bickel, C

    2003-01-01

    We have designed and developed a small field of view gamma camera, the eZ SCOPE, based on use of a CdZnTe semiconductor. This device utilises proprietary signal processing technology and an interface to a computer-based imaging system. The purpose of this study was to evaluate the performance of the eZ scope in comparison with currently employed gamma camera technology. The detector is a single wafer of 5-mm-thick CdZnTe that is divided into a 16 x 16 array (256 pixels). The sensitive area of the detector is a square of dimension 3.2 cm. Two parallel-hole collimators are provided with the system and have a matching (256 hole) pattern to the CdZnTe detector array: a low-energy, high-resolution parallel-hole (LEHR) collimator fabricated of lead and a low-energy, high-sensitivity parallel-hole (LEHS) collimator fabricated of tungsten. Performance measurements and the data analysis were done according to the procedures of the NEMA standard. We also studied the long-term stability of the system with continuous use...

  18. In situ lake pollutant survey using prompt-gamma probe

    International Nuclear Information System (INIS)

    Jiunnhsing Chao; Chien Chung

    1991-01-01

    An aluminium-made neutron-gamma probe, consisting of a 1.5 μg 252 Cf neutron source and a high purity germanium detector, was mounted on a mobile floating platform to survey chlorine pollutant concentration in lake water in situ. Laboratory tests for determining the probe operating depth and in situ field trials of a polluted lake were conducted; evaluation of radiation exposure to workers on board was carried out. The polluted chlorine concentration in lake water was found to be 86 ppm, with minimal radiation exposure for the operating crew on board. (author)

  19. Radioimmunoguided surgery using iodine 125 B72.3 in patients with colorectal cancer

    International Nuclear Information System (INIS)

    Cohen, A.M.; Martin, E.W. Jr.; Lavery, I.; Daly, J.; Sardi, A.; Aitken, D.; Bland, K.; Mojzisik, C.; Hinkle, G.

    1991-01-01

    Preliminary data using B72.3 murine monoclonal antibody labeled with iodine 125 suggested that both clinically apparent as well as occult sites of colorectal cancer could be identified intraoperatively using a hand-held gamma detecting probe. We report the preliminary data of a multicenter trial of this approach in patients with primary or recurrent colorectal cancer. One hundred four patients with primary, suspected, or known recurrent colorectal cancer received an intravenous infusion of 1 mg of B72.3 monoclonal antibody radiolabeled with 7.4 x 10 Bq of iodine 125. Twenty-six patients with primary colorectal cancer and 72 patients with recurrent colorectal cancer were examined. Using the gamma detecting probe, 78% of the patients had localization of the antibody in their tumor; this included 75% of primary tumor sites and 63% of all recurrent tumor sites; 9.2% of all tumor sites identified represented occult sites detected only with the gamma detecting probe. The overall sensitivity was 77% and a predictive value of a positive detection was 78%. A total of 30 occult sites in 26 patients were identified. In patients with recurrent cancer, the antibody study provided unique data that precluded resection in 10 patients, and in another eight patients it extended the potentially curative procedure

  20. Maintaining radiation exposures as low as reasonably achievable (ALARA) for dental personnel operating portable hand-held x-ray equipment.

    Science.gov (United States)

    McGiff, Thomas J; Danforth, Robert A; Herschaft, Edward E

    2012-08-01

    Clinical experience indicates that newly available portable hand-held x-ray units provide advantages compared to traditional fixed properly installed and operated x-ray units in dental radiography. However, concern that hand-held x-ray units produce higher operator doses than fixed x-ray units has caused regulatory agencies to mandate requirements for use of hand-held units that go beyond those recommended by the manufacturer and can discourage the use of this technology. To assess the need for additional requirements, a hand-held x-ray unit and a pair of manikins were used to measure the dose to a simulated operator under two conditions: exposures made according to the manufacturer's recommendations and exposures made according to manufacturer's recommendation except for the removal of the x-ray unit's protective backscatter shield. Dose to the simulated operator was determined using an array of personal dosimeters and a pair of pressurized ion chambers. The results indicate that the dose to an operator of this equipment will be less than 0.6 mSv y⁻¹ if the device is used according to the manufacturer's recommendations. This suggests that doses to properly trained operators of well-designed, hand-held dental x-ray units will be below 1.0 mSv y⁻¹ (2% of the annual occupational dose limit) even if additional no additional operational requirements are established by regulatory agencies. This level of annual dose is similar to those reported as typical dental personnel using fixed x-ray units and appears to satisfy the ALARA principal for this class of occupational exposures.

  1. A study of cladding technology on tube wall surface by a hand-held laser torch

    International Nuclear Information System (INIS)

    Terada, Takaya; Nishimura, Akihiko; Oka, Kiyoshi; Moriyama, Taku; Matsuda, Hiroyasu

    2015-01-01

    New maintenance technique was proposed using a hand-held laser torch for aging chemical plants and power plants. The hand-held laser torch was specially designed to be able to access limited tubular space in various cases. A composite-type optical fiberscope was composed of a center fiber for beam delivery and surrounded fibers for visible image delivery. Laser irradiation on a work pieces with the best accuracy of filler wire was carried out. And, we found that the optimized wire-feed speed was 2 mm/s in laser cladding. We succeeded to make a line clad on the inner wall of 23 mm tube. This technique was discussed to be applied to the maintenance for cracks or corrosions of tubes in various harsh environments. (author)

  2. Rotating flux-focusing eddy current probe for flaw detection

    Science.gov (United States)

    Wincheski, Russell A. (Inventor); Fulton, James P. (Inventor); Nath, Shridhar C. (Inventor); Simpson, John W. (Inventor); Namkung, Min (Inventor)

    1997-01-01

    A flux-focusing electromagnetic sensor which uses a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks about circular fasteners and other circular inhomogeneities in high conductivity material. The unique feature of the device is the ferrous shield isolating a high-turn pick-up coil from an excitation coil, The use of the magnetic shield is shown to produce a null voltage output across the receiving coil in the presence of an unflawed sample. A redistribution of the current flow in the sample caused by the presence of flaws, however, eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. By rotating the probe in a path around a circular fastener such as a rivet while maintaining a constant distance between the probe and the center of a rivet, the signal due to current flow about the rivet can be held constant. Any further changes in the current distribution, such as due to a fatigue crack at the rivet joint, can be detected as an increase in the output voltage above that due to the flow about the rivet head.

  3. Exploring field-of-view non-uniformities produced by a hand-held spectroradiometer

    Directory of Open Access Journals (Sweden)

    Tamir Caras

    2011-01-01

    Full Text Available The shape of a spectroradiometer’s field of view (FOV affects the way spectral measurements are acquired. Knowing this property is a prerequisite for the correct use of the spectrometer. If the substrate is heterogeneous, the ability to accurately know what is being measured depends on knowing the FOV location, shape, spectral and spatial sensitivity. The GER1500 is a hand-held spectrometer with a fixed lens light entry slit and has a laser guide that allows control over the target by positioning the entire unit. In the current study, the FOV of the GER1500 was mapped and analysed. The spectral and spatial non-uniformities of the FOV were examined and were found to be spectrally independent. The relationship between the FOV and the built-in laser guide was tested and found to have a linear displacement dependent on the distance to the target. This allows an accurate prediction of the actual FOV position. A correction method to improve the agreement between the expected and measured reflectance over heterogeneous targets was developed and validated. The methods described are applicable and may be of use with other hand-held spectroradiometers.

  4. Thresholds of whole-blood β-hydroxybutyrate and glucose concentrations measured with an electronic hand-held device to identify ovine hyperketonemia.

    Science.gov (United States)

    Pichler, M; Damberger, A; Schwendenwein, I; Gasteiner, J; Drillich, M; Iwersen, M

    2014-03-01

    Metabolic disorders, especially hyperketonemia, are very common in dairy sheep. The whole-blood concentrations of β-hydroxybutyrate (BHBA) and glucose can be determined by commercially available electronic hand-held devices, which are used in human medicine and for the detection of ketosis in dairy cows. The aim of this study was to evaluate the suitability of the hand-held device Precision Xceed (PX; Abbott Diabetes Care Inc., Abbott Park, IL) to detect hyperketonemia in ewes. An additional objective of this study was to evaluate the agreement between samples obtained by minimal invasive venipuncture of an ear vein and measurements of whole-blood samples from the jugular vein (vena jugularis, v. jug.). Blood samples taken from the v. jug. were collected from 358 ewes on 4 different farms. These samples and a blood drop obtained from an ear vein were analyzed simultaneously on farm with the PX. For method comparison, the samples obtained from the v. jug. were also analyzed by standard methods, which served as the gold standard at the Central Laboratory of the University of Veterinary Medicine Vienna, Austria. The correlation coefficients between the serum BHBA concentration and the concentrations measured with the hand-held meter in the whole blood from an ear vein and the v. jug. were 0.94 and 0.96, respectively. The correlation coefficients of plasma and whole-blood glucose concentration were 0.68 for the v. jug. and 0.47 for the ear vein. The mean glucose concentration was significantly lower in animals classified as hyperketonemic (BHBA ≥ 1.6 mmol/L) compared with healthy ewes. Whole-blood concentrations of BHBA and glucose measured with the PX from v. jug. showed a constant negative bias of 0.15 mmol/L and 8.4 mg/dL, respectively. Hence, a receiver operating characteristic analysis was performed to determine thresholds for the PX to detect hyperketonemia in ewes. This resulted in thresholds for moderate ketosis of BHBA concentrations of 0.7 mmol/L in blood

  5. Utility of an intraoperabive gamma probe in the surgical management of secondary or tertiary hyperparathyroidism

    NARCIS (Netherlands)

    Jorna, Francisca H.; Jager, Pieter L.; Lemstra, Clara; Wiggers, Theo; Stegeman, Coen A.; Plukker, John T. M.

    BACKGROUND: In primary hyperparathyroidism the gamma probe is effective, but its role in secondary hyperparathyroidism is unclear. We investigated the utility of the probe in the surgical management of secondary and tertiary hyperparathyroidism. METHODS: The value of the probe in guiding resection

  6. Comparison of subareolar injection lymphoscintigraphy with the 1-day and the 2-day protocols for the detection of sentinel lymph nodes in patients with breast cancer

    International Nuclear Information System (INIS)

    Seok, Ju-Won; Kim, In-Ju; Heo, Young-Jun; Yang, You-Jung; Choi, Yoo-Shin; Kim, Beom-Gyu; Park, Seoug-Jun

    2009-01-01

    Lymphoscintigraphy and sentinel node biopsy are used for the detection of axillary lymph node metastasis in breast cancer patients. However, currently there is no standardized technique. For the detection of axillary lymph node metastasis by lymphoscintigraphy and sentinel node biopsy, in patients with breast cancer, we compared the results of subareolar injections administered on the day of surgery (1-day protocol) with injections administered on the day before surgery (2-day protocol). This study included 412 breast cancer patients who underwent surgery between 2001 and 2004. For the 1-day protocol (1 h before surgery) 0.8 ml of Tc-99m Tin-Colloid (37 MBq) was injected in 203 in the subareolar region on the morning of the surgery. For the 2-day protocol (16 h before surgery) 0.8 ml of Tc-99m Tin-Colloid (185 MBq) was injected in 209 patients on the afternoon before surgery. Lymphoscintigraphy was performed in the supine position and sentinel node identification was performed by hand-held gamma probe during surgery. Among 203 patients with the 1-day protocol, 185 cases (91.1%) were identified by sentinel node lymphoscintigraphy, and 182 cases (89.7%) were identified by gamma probe. Among the 209 patients, in the 2-day protocol, 189 cases (90.4%) had the sentinel node identified by lymphoscintigraphy, and 182 cases (87.1%) by the gamma probe. There was no significant difference in the identification rate of the sentinel node between the 1-day and 2-day protocols by lymphoscintigraphy and the gamma probe (p>0.05, p>0.05). The results of the identification of the sentinel node by subareolar injection according to 1-day or 2-day protocol, in breast cancer patients, showed no significant differences. Because the 2-day protocol allows for an adequate amount of time to perform the lymphoscintigraphy, it is a more useful protocol for the identification of sentinel nodes in patients with breast cancer. (author)

  7. SIG XX - A generation of intelligent gamma ray probes

    International Nuclear Information System (INIS)

    Rusu, Al.; Bartos, D.; Constantin, F.; Caragheopol, Gh.; Cruceru, I.; Lupu, A.; Serbina, L.

    2003-01-01

    Nowadays, the radioprotection activities are governed by the ALARA principle. To comply with, we have decided to use scintillators, due to their high efficiency. The surface mounted devices allow the design of the entire gross gamma ray measuring system into a volume of about 0.5 liters. The microcontrollers having an EPROM of 4k bytes offer the opportunity to run resident programmes dedicated to: data acquisition, local processing, data transmission, and system supervising. Such an intelligence is embedded into SIG XX probes. By designing an array of such probes, one can easily obtain a portal monitor, an area monitor and so on, each of them under the the control of a PC. A few modifications may transform an intelligent probe into a portable instrument for radioprotection. In such a case, to make the probe shorter, replacing the photomultiplier by a photodiode, is an attractive goal. To reach it, a dedicated charge preamplifier has to be developed. The works and results on SIG XX probes and charge preamplifier are reported. (authors)

  8. SIG XX - a generation of intelligent gamma ray probes

    International Nuclear Information System (INIS)

    Rusu, Al.; Bartos, D.; Constantin, F.; Caragheopol, Gh; Cruceru, I.; Lupu, A.; Serbina, L.

    2005-01-01

    Full text: Nowadays, the radioprotection activities are governed by the ALARA principle. To comply with, we have decided to use scintillators, due to their large efficiency. The surface mounted devices allow the design of the entire gross gamma ray measuring system into a volume of about 0.5 liters. The microcontrollers having an EPROM of 4k bytes offer the opportunity to run resident programmes dedicated to data acquisition, local processing, data communication, system supervising. Such an intelligence is embedded into SIG XX probes. By designing an array of such probes, one can easily obtain a portal monitor, an area monitor and so on, each of them under the the control of a PC. A few modifications may transform an intelligent probe into a portable instrument for radioprotection. In such a case, to make the probe shorter, replacing the photomultiplier by a photodiode, is an attractive goal. To reach it, a dedicated charge preamplifier has to be developed. The works and results on SIG XX probes and charge preamplifier are reported. (author)

  9. Applying Hand-Held 3D Printing Technology to the Teaching of VSEPR Theory

    Science.gov (United States)

    Dean, Natalie L.; Ewan, Corrina; McIndoe, J. Scott

    2016-01-01

    The use of hand-held 3D printing technology provides a unique and engaging approach to learning VSEPR theory by enabling students to draw three-dimensional depictions of different molecular geometries, giving them an appreciation of the shapes of the building blocks of complex molecular structures. Students are provided with 3D printing pens and…

  10. Survey reveals public open to ban on hand-held cell phone use and texting.

    Science.gov (United States)

    2013-01-01

    A study performed by the Bureau of Transportation Statistics (BTS) reveals that the public is open to a ban on hand-held cell phone use while driving. The study is based on data from 2009s Omnibus Household Survey (OHS), which is administered by B...

  11. Intraoperative tumor detection: Relative performance of single-element, dual-element, and imaging probes with various collimators

    International Nuclear Information System (INIS)

    Hartsough, N.E.; Barrett, H.H.; Barber, H.B.; Woolfenden, J.M.

    1995-01-01

    Accurate tumor staging depends on finding all tumor sites, and curative surgery requires the removal of all cancerous tissue from those sites. One technique for locating tumors is to inject patients before surgery with a radiotracer that is preferentially taken up by cancerous tissue. Then, an intraoperative gamma-sensitive probe is used to locate the tumors. Small (< 1-cm diameter) tumors, often undetectable by external imaging and by the standard surgical inspection with sight and touch, can be found with probes. Simple calculations and measurements with radioactive tumor models show that small tumors should be detected by single-element probes, but often such probes fail to detect these small tumors in practice. This discrepancy is often caused by the use of a uniform background to predict probe performance. Real backgrounds are nonuniform and can decrease probe performance dramatically. Dual-element, coincidence, or imaging probes may solve the background problem. The authors devised a method to predict probe performance in a realistic background which includes variations in normal organ uptakes. They predict the relative performance of both existing probes and those in the design stage so that optimal detector and collimator configurations can be determined. The procedure includes a Monte-Carlo-calculated point-response function, a numerical torso phantom, and measured biodistribution of a monoclonal antibody. The Hotelling Trace Value, a measure of tumor-detection performance, is computed from the probe responses in simulated studies

  12. Indirect probes of the trilinear Higgs coupling: $gg \\to h$ and $h \\to \\gamma \\gamma$

    CERN Document Server

    Gorbahn, Martin

    2016-10-18

    In the framework of the Standard Model effective field theory, we examine the indirect constraints on the trilinear Higgs coupling $\\lambda$ that arise from Higgs production in gluon-gluon-fusion and diphoton Higgs decays. We calculate 2-loop contributions to the $gg \\to h$ and $h \\to \\gamma \\gamma$ amplitudes that are affected by modifications of the trilinear Higgs-boson vertex. This calculation involves both the computation of anomalous dimensions and finite matching corrections. Based on our new results, we analyse the sensitivity of present and future measurements of the $hgg$ and $h \\gamma \\gamma$ couplings to shifts in $\\lambda$. Under the assumption that $O_6 = - \\lambda \\left (H^\\dagger H \\right )^3$ is the only dimension-6 operator that alters the trilinear Higgs interactions, we find that at present the considered loop-level probes provide stronger constraints than $pp \\to 2h$. At future high-energy colliders indirect ${\\cal O} (5)$ determinations of the trilinear Higgs coupling may be possible, ma...

  13. Experimental study of the conditions for universal calibration curve for the gamma-gamma probes in 2Π-geometry

    International Nuclear Information System (INIS)

    Gyurcsak, J.; Chau, N.D.

    1989-01-01

    We present the results of the measurements performed in order of establishing the possibility of constructing the universal calibration curves for gamma-gamma density probes. It has been proved that the unit λ p , in which the source-detector distance should be expressed, has the character of a mean free path of the photons forming the high-energetic part of the spectrum. 8 refs., 12 figs., 7 tabs. (author)

  14. Hand-held optical fuel pin scanner

    International Nuclear Information System (INIS)

    Kirchner, T.L.; Powers, H.G.

    1987-01-01

    A portable, hand-held apparatus is described for optically scanning indicia imprinted about a planar end face of an article having an outer wall surface, the apparatus comprising: a supporting frame; light detector means fixed to the frame for digitizing light patterns directed thereto; indexing means on the frame for engaging the planar end face and locating the end face in a preselected focal plane on the frame. The indexing means has an inner wall surface complementary to the article wall surface for disposition thereabout and terminates in an end portion beyond the planar end face. The inner wall surface has a radially inwardly extending shoulder spaced from the end portion and engageable with the planar end face; light means directed onto the preselected focal plane; optical means mounted on the frame about a central axis, the optical means being optically interposed between the indexing means and the light detector means for directing reflected light from the preselected focal plane to the light detector means and including a dove prism centrally aligned along the central axis; and means for selectively rotating the dove prism relative to the frame about the central axis to thereby rotate the image from the focal plane as transmitted to the light detector means

  15. Comparative Geometrical Investigations of Hand-Held Scanning Systems

    Science.gov (United States)

    Kersten, T. P.; Przybilla, H.-J.; Lindstaedt, M.; Tschirschwitz, F.; Misgaiski-Hass, M.

    2016-06-01

    An increasing number of hand-held scanning systems by different manufacturers are becoming available on the market. However, their geometrical performance is little-known to many users. Therefore the Laboratory for Photogrammetry & Laser Scanning of the HafenCity University Hamburg has carried out geometrical accuracy tests with the following systems in co-operation with the Bochum University of Applied Sciences (Laboratory for Photogrammetry) as well as the Humboldt University in Berlin (Institute for Computer Science): DOTProduct DPI-7, Artec Spider, Mantis Vision F5 SR, Kinect v1 + v2, Structure Sensor and Google's Project Tango. In the framework of these comparative investigations geometrically stable reference bodies were used. The appropriate reference data were acquired by measurement with two structured light projection systems (AICON smartSCAN and GOM ATOS I 2M). The comprehensive test results of the different test scenarios are presented and critically discussed in this contribution.

  16. Gamma radiation detectors for safeguards applications

    International Nuclear Information System (INIS)

    Carchon, R.; Moeslinger, M.; Bourva, L.; Bass, C.; Zendel, M.

    2007-01-01

    The IAEA uses extensively a variety of gamma radiation detectors to verify nuclear material. These detectors are part of standardized spectrometry systems: germanium detectors for High-Resolution Gamma Spectrometry (HRGS); Cadmium Zinc Telluride (CZT) detectors for Room Temperature Gamma Spectrometry (RTGS); and NaI(Tl) detectors for Low Resolution Gamma Spectrometry (LRGS). HRGS with high-purity Germanium (HpGe) detectors cooled by liquid nitrogen is widely used in nuclear safeguards to verify the isotopic composition of plutonium or uranium in non-irradiated material. Alternative cooling systems have been evaluated and electrically cooled HpGe detectors show a potential added value, especially for unattended measurements. The spectrometric performance of CZT detectors, their robustness and simplicity are key to the successful verification of irradiated materials. Further development, such as limiting the charge trapping effects in CZT to provide improved sensitivity and energy resolution are discussed. NaI(Tl) detectors have many applications-specifically in hand-held radioisotope identification devices (RID) which are used to detect the presence of radioactive material where a lower resolution is sufficient, as they benefit from a generally higher sensitivity. The Agency is also continuously involved in the review and evaluation of new and emerging technologies in the field of radiation detection such as: Peltier-cooled CdTe detectors; semiconductor detectors operating at room temperature such as HgI 2 and GaAs; and, scintillator detectors using glass fibres or LaBr 3 . A final conclusion, proposing recommendations for future action, is made

  17. Is intra-operative gamma probe detection really necessary for inguinal sentinel lymph node biopsy?

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira Filho, Renato Santos de; Santos, Ivan Dunshe Abranches Oliveira; Ferreira, Lydia Massako; Almeida, Fernando Augusto de; Simoes, Milvia Maria; Enokihara, Silvia; Barbieri, Antonio; Tovo Filho, Reinaldo [Universidade Federal de Sao Paulo (UNIFESP - EPM), SP (Brazil). Disciplina de Cirurgia Plastica

    2000-11-01

    Sentinel node (SN) biopsy has changed the surgical treatment of malignant melanoma. The literature has emphasized the importance of gamma probe detection (GPD) of the SN. Our objective was to evaluate the efficacy of patent blue dye (PBD) and GPD for SN biopsy in different lymphatic basins. Patients with cutaneous malignant melanoma in stages I and II were submitted to biopsy of the SN, identified by PBD and GPD, as part of a research project. Patients were seen at Hospital Sao Paulo by a multidisciplinary group (Plastic Surgery Tumor Branch, Nuclear Medicine and Pathology). 64 patients with localized malignant melanoma were studied. The median age was 46.5 years. The primary tumor was located in the neck, trunk or extremities. Preoperative lymphoscintigraphy, lymphatic mapping with PBD and intraoperative GPD were performed on all patients. The SN was examined by conventional and immuno-histological staining. If the SN was not found or contained micrometastases, only complete lymphadenectomy was performed. The SN was identified by PBD if it was blue-stained, and by GPD if demonstrated activity five times greater than the adipose tissue of the neighborhood. Seventy lymphatic basins were explored. Lymphoscintigraphy showed ambiguous drainage em 7 patients. GPD identified the SN in 68 basins (97%) and PBD in 53 (76%). PBD and GPD identified SN in 100% of the inguinal basins. For the remaining basins both techniques were complementary. A metastatic SN was found in 10 basins. Three patients with negative SN had recurrence (median follow-up=11 months). Although both GPD and PBD are useful and complementary, PBD alone identified the SN in 100% of the inguinal lymphatic basins. (author)

  18. Is intra-operative gamma probe detection really necessary for inguinal sentinel lymph node biopsy?

    International Nuclear Information System (INIS)

    Oliveira Filho, Renato Santos de; Santos, Ivan Dunshe Abranches Oliveira; Ferreira, Lydia Massako; Almeida, Fernando Augusto de; Simoes, Milvia Maria; Enokihara, Silvia; Barbieri, Antonio; Tovo Filho, Reinaldo

    2000-01-01

    Sentinel node (SN) biopsy has changed the surgical treatment of malignant melanoma. The literature has emphasized the importance of gamma probe detection (GPD) of the SN. Our objective was to evaluate the efficacy of patent blue dye (PBD) and GPD for SN biopsy in different lymphatic basins. Patients with cutaneous malignant melanoma in stages I and II were submitted to biopsy of the SN, identified by PBD and GPD, as part of a research project. Patients were seen at Hospital Sao Paulo by a multidisciplinary group (Plastic Surgery Tumor Branch, Nuclear Medicine and Pathology). 64 patients with localized malignant melanoma were studied. The median age was 46.5 years. The primary tumor was located in the neck, trunk or extremities. Preoperative lymphoscintigraphy, lymphatic mapping with PBD and intraoperative GPD were performed on all patients. The SN was examined by conventional and immuno-histological staining. If the SN was not found or contained micrometastases, only complete lymphadenectomy was performed. The SN was identified by PBD if it was blue-stained, and by GPD if demonstrated activity five times greater than the adipose tissue of the neighborhood. Seventy lymphatic basins were explored. Lymphoscintigraphy showed ambiguous drainage em 7 patients. GPD identified the SN in 68 basins (97%) and PBD in 53 (76%). PBD and GPD identified SN in 100% of the inguinal basins. For the remaining basins both techniques were complementary. A metastatic SN was found in 10 basins. Three patients with negative SN had recurrence (median follow-up=11 months). Although both GPD and PBD are useful and complementary, PBD alone identified the SN in 100% of the inguinal lymphatic basins. (author)

  19. ScoutTM, a portable MCA system

    International Nuclear Information System (INIS)

    Cheng, A.Y.; Ziemba, F.P.; Browning, J.E.; Szluk, N.

    1998-01-01

    Quantrad Sensor's hand-held multichannel analyzer (MCA), the Scout TM , has evolved considerably from the initial licensing from Pacific Northwest Laboratories (operated by Battelle Memorial Institute for the U.S. DOE). The Scout TM has grown into a flexible MCA system with alpha-, gamma-, X-ray and neutron detection capabilities with wide ranging applications. The development philosophy is discussed along with specific examples of design choices in areas such as manufacturability, upgradability, probe interchangability and software user interface. Recently introduced products include: software enhancements, additional probes, customized software and a second generation instrument, the Scout512 TM , that boasts increased capabilities. Future developments are also discussed. (author)

  20. Development of a bottom-hole gamma-ray diagnostic capability for high-level environments, during CTBT on-site inspection drilling

    International Nuclear Information System (INIS)

    Fontenot, R.; Shakir, S.; Heuze, F.; Butler, M.

    1998-05-01

    Testing completed at NTS confirmed that the Anadrill gamma-ray tool was fully operational up to 50,000 API, as specified in the initial objective. Recorded results were within expected ranges when compared to the hand-held detector. The gamma-ray module will require special 'high-rate' detection software to be loaded prior to drilling operations. The other components within the VIPER system have been modified to operate with either software (normal or 'high-rate') installed in the gamma-ray module. The successful completion of this test is but one step towards the main goal. The next step will be testing this module in the VIPER tool during an actual 're-entry' drilling operation, which could be performed at NTS on a former U.S. event. (author)

  1. Hand-held cell phone use while driving legislation and observed driver behavior among population sub-groups in the United States

    OpenAIRE

    Rudisill, Toni M.; Zhu, Motao

    2017-01-01

    Abstract Background Cell phone use behaviors are known to vary across demographic sub-groups and geographic locations. This study examined whether universal hand-held calling while driving bans were associated with lower road-side observed hand-held cell phone conversations across drivers of different ages (16–24, 25–59, ≥60 years), sexes, races (White, African American, or other), ruralities (suburban, rural, or urban), and regions (Northeast, Midwest, South, and West). Methods Data from the...

  2. Stress fractures of the hind limb in 2 Thoroughbreds

    International Nuclear Information System (INIS)

    Nelson, A.

    1994-01-01

    Stress factures are a common arthopaedic injury in human and equine athletes (McBryde 1985; Mackey et al. 1987). Although often presenting as acute lameness in the horse they are the accumulation of a long period of bone remodelling and eventual failure (Jones and Harris 1989). Gamma scintigraphy has been useful in the diagnosis of stress fractures in humans (Prather et al. 1977) and horses (Devous and Twardock 1984) and is more sensitive than radiography due to its ability to detect functional changes in bone metabolism (Matin 1988). Gamma scintigraphy may be performed in the horse using a hand held probe (Pilsworth 1989) or a gamma camera (Ueltshi 1977). The following cases were both investigated using a gamma camera and dedicated computer system (Elscint UK, Colonial Business Park, Watford, UK)

  3. COMPARATIVE GEOMETRICAL INVESTIGATIONS OF HAND-HELD SCANNING SYSTEMS

    Directory of Open Access Journals (Sweden)

    T. P. Kersten

    2016-06-01

    Full Text Available An increasing number of hand-held scanning systems by different manufacturers are becoming available on the market. However, their geometrical performance is little-known to many users. Therefore the Laboratory for Photogrammetry & Laser Scanning of the HafenCity University Hamburg has carried out geometrical accuracy tests with the following systems in co-operation with the Bochum University of Applied Sciences (Laboratory for Photogrammetry as well as the Humboldt University in Berlin (Institute for Computer Science: DOTProduct DPI-7, Artec Spider, Mantis Vision F5 SR, Kinect v1 + v2, Structure Sensor and Google’s Project Tango. In the framework of these comparative investigations geometrically stable reference bodies were used. The appropriate reference data were acquired by measurement with two structured light projection systems (AICON smartSCAN and GOM ATOS I 2M. The comprehensive test results of the different test scenarios are presented and critically discussed in this contribution.

  4. A hand-held row-column addressed CMUT probe with integrated electronics for volumetric imaging

    DEFF Research Database (Denmark)

    Engholm, Mathias; Christiansen, Thomas Lehrmann; Beers, Christopher

    2015-01-01

    A 3 MHz, λ / 2-pitch 62+62 channel row-column addressed 2-D CMUT array designed to be mounted in a probe handle and connected to a commercial BK Medical scanner for real-time volumetric imaging is presented. It is mounted and wire-bonded on a flexible PCB, which is connected to two rigid PCBs...

  5. Method of shaping of direction-characterization of sensitivity of ionizing radiation detection probe

    International Nuclear Information System (INIS)

    Czarnecki, J.; Jaszczuk, J.; Kruczyk, M.; Slapa, M.; Wroblewski, T.

    1986-01-01

    A method of shaping of direction-characterization of sensitivity of the ionizing radiation detection probe, especially equipped with small gamma detectors is described. Two detectors are placed coaxially in the bases of the cylindrical shield. One of them is uncovered in the highest degree and the second is not covered to a maximum. The signals from them are processed on the standarized sequences of electrical impulses (taking into account the heights and the widths of the amplitude). 2 figs., 1 tab. (A.S.)

  6. Gamma Ray Bursts as Cosmological Probes with EXIST

    Science.gov (United States)

    Hartmann, Dieter; EXIST Team

    2006-12-01

    The EXIST mission, studied as a Black Hole Finder Probe within NASA's Beyond Einstein Program, would, in its current design, trigger on 1000 Gamma Ray Bursts (GRBs) per year (Grindlay et al, this meeting). The redshift distribution of these GRBs, using results from Swift as a guide, would probe the z > 7 epoch at an event rate of > 50 per year. These bursts trace early cosmic star formation history, point to a first generation of stellar objects that reionize the universe, and provide bright beacons for absorption line studies with groundand space-based observatories. We discuss how EXIST, in conjunction with other space missions and future large survey programs such as LSST, can be utilized to advance our understanding of cosmic chemical evolution, the structure and evolution of the baryonic cosmic web, and the formation of stars in low metallicity environments.

  7. Hand-held tidal breathing nasal nitric oxide measurement--a promising targeted case-finding tool for the diagnosis of primary ciliary dyskinesia

    DEFF Research Database (Denmark)

    Marthin, June Kehlet; Nielsen, Kim Gjerum

    2013-01-01

    BACKGROUND: Nasal nitric oxide (nNO) measurement is an established first line test in the work-up for primary ciliary dyskinesia (PCD). Tidal breathing nNO (TB-nNO) measurements require minimal cooperation and are potentially useful even in young children. Hand-held NO devices are becoming...... increasingly widespread for asthma management. Therefore, we chose to assess whether hand-held TB-nNO measurements reliably discriminate between PCD, and Healthy Subjects (HS) and included Cystic Fibrosis (CF) patients as a disease control group known to have intermediate nNO levels. METHODS: In this cross...... sectional, single centre, single occasion, proof-of-concept study in children and adults with PCD and CF, and in HS we compared feasibility, success rates, discriminatory capacity, repeatability and agreement between a hand-held electrochemical device equipped with a nNO software application sampling...

  8. Hand-held Raman sensor head for in-situ characterization of meat quality applying a microsystem 671 nm diode laser

    Science.gov (United States)

    Schmidt, Heinar; Sowoidnich, Kay; Maiwald, Martin; Sumpf, Bernd; Kronfeldt, Heinz-Detlef

    2009-05-01

    A hand-held Raman sensor head was developed for the in-situ characterization of meat quality. As light source, a microsystem based external cavity diode laser module (ECDL) emitting at 671 nm was integrated in the sensor head and attached to a miniaturized optical bench which contains lens optics for excitation and signal collection as well as a Raman filter stage for Rayleigh rejection. The signal is transported with an optical fiber to the detection unit which was in the initial phase a laboratory spectrometer with CCD detector. All elements of the ECDL are aligned on a micro optical bench with 13 x 4 mm2 footprint. The wavelength stability is provided by a reflection Bragg grating and the laser has an optical power of up to 200 mW. However, for the Raman measurements of meat only 35 mW are needed to obtain Raman spectra within 1 - 5 seconds. Short measuring times are essential for the hand-held device. The laser and the sensor head are characterized in terms of stability and performance for in-situ Raman investigations. The function is demonstrated in a series of measurements with raw and packaged pork meat as samples. The suitability of the Raman sensor head for the quality control of meat and other products will be discussed.

  9. Rapid and automatic chemical identification of the medicinal flower buds of Lonicera plants by the benchtop and hand-held Fourier transform infrared spectroscopy

    Science.gov (United States)

    Chen, Jianbo; Guo, Baolin; Yan, Rui; Sun, Suqin; Zhou, Qun

    2017-07-01

    With the utilization of the hand-held equipment, Fourier transform infrared (FT-IR) spectroscopy is a promising analytical technique to minimize the time cost for the chemical identification of herbal materials. This research examines the feasibility of the hand-held FT-IR spectrometer for the on-site testing of herbal materials, using Lonicerae Japonicae Flos (LJF) and Lonicerae Flos (LF) as examples. Correlation-based linear discriminant models for LJF and LF are established based on the benchtop and hand-held FT-IR instruments. The benchtop FT-IR models can exactly recognize all articles of LJF and LF. Although a few LF articles are misjudged at the sub-class level, the hand-held FT-IR models are able to exactly discriminate LJF and LF. As a direct and label-free analytical technique, FT-IR spectroscopy has great potential in the rapid and automatic chemical identification of herbal materials either in laboratories or in fields. This is helpful to prevent the spread and use of adulterated herbal materials in time.

  10. Gamma rays as probe of fission and quasi-fission dynamics in the reaction 32S + 197Au near the Coulomb barrier

    Science.gov (United States)

    Pulcini, A.; Vardaci, E.; Kozulin, E.; Ashaduzzaman, M.; Borcea, C.; Bracco, A.; Brambilla, S.; Calinescu, S.; Camera, F.; Ciemala, M.; de Canditiis, B.; Dorvaux, O.; Harca, I. M.; Itkis, I.; Kirakosyan, V. V.; Knyazheva, G.; Kozulina, N.; Kolesov, I. V.; La Rana, G.; Maj, A.; Matea, I.; Novikov, K.; Petrone, C.; Quero, D.; Rath, P.; Saveleva, E.; Schmitt, C.; Sposito, G.; Stezowski, O.; Trzaska, W. H.; Wilson, J.

    2018-05-01

    Compound nucleus fission and quasi-fission are both binary decay channels whose common properties make the experimental separation between them difficult. A way to achieve this separation could be to probe the angular momentum of the binary fragments. This can be done detecting gamma rays in coincidence with the two fragments. As a case study, the reaction 32S + 197Au near the Coulomb barrier has been performed at the Tandem ALTO facility at IPN ORSAY. ORGAM and PARIS, two different gamma detectors arrays, are coupled with the CORSET detector, a two-arm time-of-flight spectrometer. TOF-TOF data were analyzed to reconstruct the mass-energy distribution of the primary fragments coupled with gamma multiplicity and spectroscopic analysis. Preliminary results of will be shown.

  11. Minimum dimensions of rock models for calibration of radiometric probes for the neutron-gamma well logging

    International Nuclear Information System (INIS)

    Czubek, J.A.; Lenda, A.

    1979-01-01

    The minimum dimensions have been calculated assuring 91, 96 and 98 % of the probe response in respect to the infinite medium. The models are of cylindrical form, the probe (source-to-detector distance equal to 60 or 90 cm) being placed on the model axis, symmetrically with respect to the two end-faces. All the models are ''embedded'' in various media, such as: air, sand of 40% porosity and completely saturated with water, sand of 30 % porosity and of moisture content equal to 10 %, and water. The models are of three types of material: sandstone, limestone and dolomite, with various porosities, ranging from 0 to 100 %. The probe response is due to gamma rays arising from the radiativecapture of thermal neutrons. The calculations were carried out for the highest energy line of gamma rays arising in given litology. Gamma-ray flux from the neutron radiative capture has been calculated versus rock porosity and model dimensions and radiation migration lengths determined for given litologies. The minimum dimensions of cylindrical models are given as functions of: porosity, probe length (source-to-detector distance) lithology of model and type of medium surrounding our model. (author)

  12. Hand-held indirect calorimeter offers advantages compared with prediction equations, in a group of overweight women, to determine resting energy expenditures and estimated total energy expenditures during research screening.

    Science.gov (United States)

    Spears, Karen E; Kim, Hyunsook; Behall, Kay M; Conway, Joan M

    2009-05-01

    To compare standardized prediction equations to a hand-held indirect calorimeter in estimating resting energy and total energy requirements in overweight women. Resting energy expenditure (REE) was measured by hand-held indirect calorimeter and calculated by prediction equations Harris-Benedict, Mifflin-St Jeor, World Health Organization/Food and Agriculture Organization/United Nations University (WHO), and Dietary Reference Intakes (DRI). Physical activity level, assessed by questionnaire, was used to estimate total energy expenditure (TEE). Subjects (n=39) were female nonsmokers older than 25 years of age with body mass index more than 25. Repeated measures analysis of variance, Bland-Altman plot, and fitted regression line of difference. A difference within +/-10% of two methods indicated agreement. Significant proportional bias was present between hand-held indirect calorimeter and prediction equations for REE and TEE (Pvalues and underestimated at higher values. Mean differences (+/-standard error) for REE and TEE between hand-held indirect calorimeter and Harris-Benedict were -5.98+/-46.7 kcal/day (P=0.90) and 21.40+/-75.7 kcal/day (P=0.78); between hand-held indirect calorimeter and Mifflin-St Jeor were 69.93+/-46.7 kcal/day (P=0.14) and 116.44+/-75.9 kcal/day (P=0.13); between hand-held indirect calorimeter and WHO were -22.03+/-48.4 kcal/day (P=0.65) and -15.8+/-77.9 kcal/day (P=0.84); and between hand-held indirect calorimeter and DRI were 39.65+/-47.4 kcal/day (P=0.41) and 56.36+/-85.5 kcal/day (P=0.51). Less than 50% of predictive equation values were within +/-10% of hand-held indirect calorimeter values, indicating poor agreement. A significant discrepancy between predicted and measured energy expenditure was observed. Further evaluation of hand-held indirect calorimeter research screening is needed.

  13. CsI/PIN Diode Detector Manufacture and Gamma-ray Response Measurement

    International Nuclear Information System (INIS)

    Ha, Jang Ho; Park, Se Hwan; Kang, Sang Mook; Kim, Yong Kyun; Lee, Wo Kyu

    2007-01-01

    In the nuclear industry changes fast to expand from conventional industry to newly emerging market industry. Such industries are environment and security field. Conventional devices to field-orientation application are too heavy not enough to be hand held. Especially emerging environment and security markets need a device which should be handheld and available long term battery operation. Photomultiplier based detection system could not satisfied these requirements. One of the promising system is the scintillator/PIN diode device. Present investigation is motivated for the purpose of developing a gamma-ray monitoring system with nuclei identification and small and light enough to be transportable by worker

  14. Calibration of SAR probes in waveguide at 900 MHz

    International Nuclear Information System (INIS)

    Jokela, K.; Puranen, L.; Hyysalo, P.

    1998-01-01

    The radiation safety tests for hand-held mobile phones require precise calibration of the small electric field probes used for the measurement of SAR in phantoms simulating the human body. In this study a calibration based on a rectangular waveguide was developed for SAR calibrations at 900 MHz

  15. Finger tips detection for two handed gesture recognition

    Science.gov (United States)

    Bhuyan, M. K.; Kar, Mithun Kumar; Neog, Debanga Raj

    2011-10-01

    In this paper, a novel algorithm is proposed for fingertips detection in view of two-handed static hand pose recognition. In our method, finger tips of both hands are detected after detecting hand regions by skin color-based segmentation. At first, the face is removed in the image by using Haar classifier and subsequently, the regions corresponding to the gesturing hands are isolated by a region labeling technique. Next, the key geometric features characterizing gesturing hands are extracted for two hands. Finally, for all possible/allowable finger movements, a probabilistic model is developed for pose recognition. Proposed method can be employed in a variety of applications like sign language recognition and human-robot-interactions etc.

  16. Natural-pose hand detection in low-resolution images

    Directory of Open Access Journals (Sweden)

    Nyan Bo Bo1

    2009-07-01

    Full Text Available Robust real-time hand detection and tracking in video sequences would enable many applications in areas as diverse ashuman-computer interaction, robotics, security and surveillance, and sign language-based systems. In this paper, we introducea new approach for detecting human hands that works on single, cluttered, low-resolution images. Our prototype system, whichis primarily intended for security applications in which the images are noisy and low-resolution, is able to detect hands as smallas 2424 pixels in cluttered scenes. The system uses grayscale appearance information to classify image sub-windows as eithercontaining or not containing a human hand very rapidly at the cost of a high false positive rate. To improve on the false positiverate of the main classifier without affecting its detection rate, we introduce a post-processor system that utilizes the geometricproperties of skin color blobs. When we test our detector on a test image set containing 106 hands, 92 of those hands aredetected (86.8% detection rate, with an average false positive rate of 1.19 false positive detections per image. The rapiddetection speed, the high detection rate of 86.8%, and the low false positive rate together ensure that our system is useable asthe main detector in a diverse variety of applications requiring robust hand detection and tracking in low-resolution, clutteredscenes.

  17. Design of hand held RID's monitoring system based on embedded system

    International Nuclear Information System (INIS)

    Wang Hongwei; Wei Yixiang

    2008-01-01

    In this paper we introduce the design of monitoring system for the hand held radionuclide identification device (RID), constructed under the embedded operating system of WinCE. At first, we introduce the design of hardware and software platform, and following is the major part of technical view of the software system, including the driver development, P/Invoke mechanism to call the C/C++ subroutines, multi-thread technology. In the experimental hardware platform, we have developed a front-end monitoring system for portable device targeted nuclide identification and orientation. It's a full-featured and flexible system, with the functions of data acquisition, radioactivity locating, data import and export, etc. (authors)

  18. Multiple Gamma-Ray Detection Capability of a CeBr3 Detector for Gamma Spectroscopy

    Directory of Open Access Journals (Sweden)

    A. A. Naqvi

    2017-01-01

    Full Text Available The newly developed cerium tribromide (CeBr3 detector has reduced intrinsic gamma-ray activity with gamma energy restricted to 1400–2200 keV energy range. This narrower region of background gamma rays allows the CeBr3 detector to detect more than one gamma ray to analyze the gamma-ray spectrum. Use of multiple gamma-ray intensities in elemental analysis instead of a single one improves the accuracy of the estimated results. Multigamma-ray detection capability of a cylindrical 75 mm × 75 mm (diameter × height CeBr3 detector has been tested by analyzing the chlorine concentration in water samples using eight chlorine prompt gamma rays over 517 to 8578 keV energies utilizing a D-D portable neutron generator-based PGNAA setup and measuring the corresponding minimum detection limit (MDC of chlorine. The measured MDC of chlorine for gamma rays with 517–8578 keV energies varies from 0.07 ± 0.02 wt% to 0.80 ± 0.24. The best value of MDC was measured to be 0.07 ± 0.02 wt% for 788 keV gamma rays. The experimental results are in good agreement with Monte Carlo calculations. The study has shown excellent detection capabilities of the CeBr3 detector for eight prompt gamma rays over 517–8578 keV energy range without significant background interference.

  19. Hand-Held Sunphotometers for High School Student Construction and Measuring Aerosol Optical Thickness

    Science.gov (United States)

    Almonor, Linda; Baldwin, C.; Craig, R.; Johnson, L. P.

    2000-01-01

    Science education is taking the teaching of science from a traditional (lecture) approach to a multidimensional sense-making approach which allows teachers to support students by providing exploratory experiences. Using projects is one way of providing students with opportunities to observe and participate in sense-making activity. We created a learning environment that fostered inquiry-based learning. Students were engaged in a variety of Inquiry activities that enabled them to work in cooperative planning teams where respect for each other was encouraged and their ability to grasp, transform and transfer information was enhanced. Summer, 1998: An air pollution workshop was conducted for high school students in the Medgar Evers College/Middle College High School Liberty Partnership Summer Program. Students learned the basics of meteorology: structure and composition of the atmosphere and the processes that cause weather. The highlight of this workshop was the building of hand-held sunphotometers, which measure the intensity of the sunlight striking the Earth. Summer, 1999: high school students conducted a research project which measured the mass and size of ambient particulates and enhanced our ability to observe through land based measurements changes in the optical depth of ambient aerosols over Brooklyn. Students used hand held Sunphotometers to collect data over a two week period and entered it into the NASA GISS database by way of the internet.

  20. Probing a Possible Vacuum Refractive Index with Gamma-Ray Telescopes

    CERN Document Server

    Ellis, John; Nanopoulos, D V; PH-TH

    2009-01-01

    We have used a stringy model of quantum space-time foam to suggest that the vacuum may exhibit a non-trivial refractive index depending linearly on gamma-ray energy: eta -1 ~ E_gamma/M_QG1, where M_QG1 is some mass scale typical of quantum gravity that may be ~ 10^18 GeV: see Phys. Lett. B 665, 412 (2008) and references therein. The MAGIC, HESS and Fermi gamma-ray telescopes have recently probed the possible existence of such an energy-dependent vacuum refractive index. All find indications of time-lags for higher-energy photons, but cannot exclude the possibility that they are due to intrinsic delays at the sources. However, the MAGIC and HESS observations of time-lags in emissions from AGNs Mkn 501 and PKS 2155-304 are compatible with each other and a refractive index depending linearly on the gamma-ray energy, with M_QG1 ~ 10^18 GeV. We combine their results to estimate the time-lag Delta t to be expected for the highest-energy photon from GRB 080916c measured by the Fermi telescope, which has an energy ~ ...

  1. Portable gamma and thermal neutron probe using a 6LiI(Eu) crystal

    International Nuclear Information System (INIS)

    Carneiro, Clemente J.G.; Araujo, Geraldo P.; Milian, Felix M.; Barbosa, Jurandir C.; Garcia, Fermin; Oliveira, Arno H.; Silva, Mario R.S.; Penna, Rodrigo

    2011-01-01

    Europium-activated lithium-6 iodide is a scintillator used for gamma and neutron counting. A portable detection system was built based on this scintillator. This system has three modules: the scintillator, a 10 m liquid light guide, and a Hamamatsu photon counting head H9319 used as a light pulse digitizer. Data transfer, measurement time and other necessary adjustment can be controlled by software from the PC through the RS-232C interface. The scintillator, a crystal of 6 LiI(Eu), is a small cylinder with 3 mm diameter and 40 mm length completely sealed in an aluminum tube coupled to the light guide. The small size of the scintillator increases the neutron/gamma count ratio, since 2 to 3 mm of thickness of this crystal absorbs all thermal neutrons. Intensities of X and gamma rays, and thermal neutrons can be recorded for time intervals of 10 ms to 1 s storing up to 10000 countings. The system was calibrated for measuring radiation doses for validating numerical models in dosimetry. Two characteristic reinforce this application, measurements can be done at several meters away from the radiation source and also inside of water. In addition, it was used to build nuclear probes based on Compton scattering or neutron moderation in porous media by attaching an AmBe source to the top of the aluminum tube. Tests were done to determine the reproducibility of counting rates. Background counting was measured at several temperatures to verify the influence of dark current of PMT. Sealed AmBe, low activity Am, and X rays sources were used for studies of radiation counting statistics. X rays apparatus was used to correlate counting rates measured with the 6 LiI(Eu) detection system and doses measured with an ionization chamber at several distances from the X ray source. (author)

  2. Self-powered detector probes for electron and gamma-ray beam monitoring in high-power industrial accelerators

    International Nuclear Information System (INIS)

    Lone, M.A.

    1992-08-01

    A self-powered detector (SPD) is a simple passive device that consists of a coaxial probe with a metallic outer sleeve, a mineral oxide insulating layer, and a metallic inner core. SPDs are used in nuclear reactors for monitoring neutron and gamma ray fields. Responses of various SPDs to electron and gamma ray beams from industrial accelerators were investigated with Monte Carlo simulations. By judicious choice of transmission filters, threshold SPD probes were investigated for on-line monitoring of the beam energy spectrum of the high-power IMPELA industrial electron accelerator. (Author) (14 figs, 16 refs.)

  3. Development of a hand-held fast neutron survey meter

    International Nuclear Information System (INIS)

    Yoshida, T.; Tsujimura, N.; Yamano, T.

    2011-01-01

    A neutron survey meter with a ZnS(Ag) scintillator to measure recoil protons was built. The detection probe weighs ∼2 kg, therefore providing us with true portability. Performance tests exhibited satisfactory neutron dosimetry characteristics in unmoderated or lightly moderated fission neutron fields and in particular work environments at a mixed oxide fuel facility. This new survey meter will augment a routine of neutron monitoring that is inconveniently being carried out by moderator-based neutron survey meters. (authors)

  4. Multipartite entanglement detection with nonsymmetric probing

    DEFF Research Database (Denmark)

    Dellantonio, Luca; Das, Sumanta; Appel, Jürgen

    2017-01-01

    We show that spin-squeezing criteria commonly used for entanglement detection can be erroneous if the probe is not symmetric. We then derive a lower bound on squeezing for separable states in spin systems probed asymmetrically. Using this we further develop a procedure that allows us to verify th...... the degree of entanglement of a quantum state in the spin system. Finally, we apply our method for entanglement verification to existing experimental data, and use it to prove the existence of tripartite entanglement in a spin-squeezed atomic ensemble.......We show that spin-squeezing criteria commonly used for entanglement detection can be erroneous if the probe is not symmetric. We then derive a lower bound on squeezing for separable states in spin systems probed asymmetrically. Using this we further develop a procedure that allows us to verify...

  5. Precise intraoperative location of gastrointestinal bleeding with a hand-held counter. Work in progress

    International Nuclear Information System (INIS)

    Williamson, M.R.; Boyd, C.M.; McGuire, E.L.

    1986-01-01

    The nuclear medicine bleeding scan is frequently insufficient to locate sites of bleeding precisely, in spite of its great sensitivity. A small, hand-held Geiger-Mueller counter, placed directly on exposed intestine in the operating room, enables precise location of the probable bleeding site. In three patients, the technique allowed a minimal amount of intestine to be resected, distinguished between large- and small-intestinal hemorrhage, and eliminated other foci as sites of bleeding.A

  6. Single isotopic probe for gastro-esophageal reflux diagnosis in children

    Energy Technology Data Exchange (ETDEWEB)

    Maurel, G.; Le Moing, G.; Mensch, B.

    1987-03-01

    Gastro-esophageal reflux (GER) in children has been implicated in various recurring respiratory diseases. Several techniques including oesophageal pH testing and scintigraphy have been devised to detect and quantify GER Limitations have been found for each test: short duration with gamma-camera and restricted acceptability of the pH probe by children. A single isotopic probe was designed for a non-invasive screening test of GER in infants. This device was checked by comparison with oesophageal scintigraphy using a gamma camera. Only 1 discrepancy was detected in 19 reflux episodes. This method, using a relatively inexpensive detector and data acquisition module, seems to be well accepted by children, and may be associated with a pH probe for GER diagnosis.

  7. MAGNETIC STRUCTURES IN GAMMA-RAY BURST JETS PROBED BY GAMMA-RAY POLARIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Yonetoku, Daisuke; Murakami, Toshio; Morihara, Yoshiyuki; Takahashi, Takuya; Wakashima, Yudai; Yonemochi, Hajime; Sakashita, Tomonori; Fujimoto, Hirofumi; Kodama, Yoshiki [College of Science and Engineering, School of Mathematics and Physics, Kanazawa University, Kakuma, Kanazawa, Ishikawa 920-1192 (Japan); Gunji, Shuichi; Toukairin, Noriyuki [Department of Physics, Faculty of Science, Yamagata University, 1-4-12, Koshirakawa, Yamagata, Yamagata 990-8560 (Japan); Mihara, Tatehiro [Cosmic Radiation Laboratory, RIKEN, 2-1, Hirosawa, Wako City, Saitama 351-0198 (Japan); Toma, Kenji, E-mail: yonetoku@astro.s.kanazawa-u.ac.jp [Department of Earth and Space Science, Osaka University, Toyonaka 560-0043 (Japan)

    2012-10-10

    We report polarization measurements in two prompt emissions of gamma-ray bursts, GRB 110301A and GRB 110721A, observed with the gamma-ray burst polarimeter (GAP) on borad the IKAROS solar sail mission. We detected linear polarization signals from each burst with polarization degree of {Pi} = 70 {+-} 22% with statistical significance of 3.7{sigma} for GRB 110301A, and {Pi} = 84{sup +16}{sub -28}% with 3.3{sigma} confidence level for GRB 110721A. We did not detect any significant change of polarization angle. These two events had shorter durations and dimmer brightness compared with GRB 100826A, which showed a significant change of polarization angle, as reported in Yonetoku et al. Synchrotron emission model can be consistent with the data of the three GRBs, while the photospheric quasi-thermal emission model is not favored. We suggest that magnetic field structures in the emission region are globally ordered fields advected from the central engine.

  8. Detection of gamma-neutron radiation by solid-state scintillation detectors. Detection of gamma-neutron radiation by novel solid-state scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Ryzhikov, V.; Grinyov, B.; Piven, L.; Onyshchenko, G.; Sidletskiy, O. [Institute for Scintillation Materials of the NAS of Ukraine, Kharkov, (Ukraine); Naydenov, S. [Institute for Single Crystals of the National Academy of Sciences of Ukraine, Kharkov, (Ukraine); Pochet, T. [DETEC-Europe, Vannes (France); Smith, C. [Naval Postgraduate School, Monterey, CA (United States)

    2015-07-01

    It is known that solid-state scintillators can be used for detection of both gamma radiation and neutron flux. In the past, neutron detection efficiencies of such solid-state scintillators did not exceed 5-7%. At the same time it is known that the detection efficiency of the gamma-neutron radiation characteristic of nuclear fissionable materials is by an order of magnitude higher than the efficiency of detection of neutron fluxes alone. Thus, an important objective is the creation of detection systems that are both highly efficient in gamma-neutron detection and also capable of exhibiting high gamma suppression for use in the role of detection of neutron radiation. In this work, we present the results of our experimental and theoretical studies on the detection efficiency of fast neutrons from a {sup 239}Pu-Be source by the heavy oxide scintillators BGO, GSO, CWO and ZWO, as well as ZnSe(Te, O). The most probable mechanism of fast neutron interaction with nuclei of heavy oxide scintillators is the inelastic scattering (n, n'γ) reaction. In our work, fast neutron detection efficiencies were determined by the method of internal counting of gamma-quanta that emerge in the scintillator from (n, n''γ) reactions on scintillator nuclei with the resulting gamma energies of ∼20-300 keV. The measured efficiency of neutron detection for the scintillation crystals we considered was ∼40-50 %. The present work included a detailed analysis of detection efficiency as a function of detector and area of the working surface, as well as a search for new ways to create larger-sized detectors of lower cost. As a result of our studies, we have found an unusual dependence of fast neutron detection efficiency upon thickness of the oxide scintillators. An explanation for this anomaly may involve the competition of two factors that accompany inelastic scattering on the heavy atomic nuclei. The transformation of the energy spectrum of neutrons involved in the (n, n

  9. Proceedings of the workshop on multiple prompt gamma-ray analysis

    International Nuclear Information System (INIS)

    Ebihara, Mitsuru; Hatsukawa, Yuichi; Oshima, Masumi

    2006-10-01

    The workshop on 'Multiple Prompt Gamma-ray Analysis' was held on March 8, 2006 at Tokai. It is based on a project, 'Developments of real time, non-destructive ultra sensitive elemental analysis using multiple gamma-ray detections and prompt gamma ray analysis and its application to real samples', one of the High priority Cooperative Research Programs performed by Japan Atomic Energy Agency and the University of Tokyo. In this workshop, the latest results of the Multiple Prompt Gamma ray Analysis (MPGA) study were presented, together with those of Neutron Activation Analysis with Multiple Gamma-ray Detection (NAAMG). The 9 of the presented papers are indexed individually. (J.P.N.)

  10. Gamma-Ray Bursts: 4th Huntsville Symposium. Proceedings

    International Nuclear Information System (INIS)

    Meegan, C.A.; Preece, R.D.; Koshut, T.M.

    1998-01-01

    These proceedings represent papers presented at the Fourth Huntsville Gamma-Ray Bursts Symposium held in September, 1997 in Huntsville, Alabama, USA. This conference occurred at a crucial time in the history of the gamma-ray burst research. In early 1997, 30 years after the detection of the first gamma-ray burst by the Vela satellites, counterparts to bursts were finally detected at optical and radio wavelengths. The symposium attracted about 200 scientists from 16 countries. Some of the topics discussed include gamma-ray burst spectra, x-ray observations, optical observations, radio observations, host galaxies, shocks and afterglows and models of gamma-ray bursts. There were 183 papers presented, out of these, 16 have been abstracted for the Energy Science and Technology database

  11. Assembly of gamma radiation detection with directivity properties

    International Nuclear Information System (INIS)

    Stoica, M.; Talpalariu, C.

    2016-01-01

    An assembly of gamma radiation detection with directivity properties and small size enables the development of portable equipment or robots specialized in finding and signaling radioactively contaminated areas in case of nuclear incidents or decommissioning of nuclear installations. Directivity characteristic of the assembly of gamma radiation detection is very important when aiming to build an equipment for searching radioactively contaminated areas. In order to obtain a suitable directivity characteristics in terms of detection of gamma rays, it was necessary to construct a lead collimator with a cylindrical shape. The detector, preamplifier and amplifier pulse were placed inside the collimator and pulse discriminator circuit and power source were placed beside the collimator, all being disposed within the housing cylindrical experimental. A PIN photodiode type was used as a detector of gamma radiation. (authors)

  12. Use of gamma probe in {sup 131}I thyroid uptake studies; Utilizacao da sonda a cintilacao na captacao de {sup 131}I pela tireoide

    Energy Technology Data Exchange (ETDEWEB)

    Sarmento, Andrea Gondim Leitao

    2002-11-01

    Evaluation of thyroid uptake by administration of radioactive iodine is a well-defined procedure to assess patient thyroid function. In general, nuclear medicine institutions use gamma cameras coupled to pinhole collimators to perform uptake studies. With the growing use of intraoperative gamma probes in the radioguided surgical techniques, several institutions are purchasing this new and portable equipment, which can technically be also employed to assess patient's thyroid function, permitting further other applications of gamma cameras. The aim of the study was to compare thyroid uptake trails carried out with both gamma camera and intraoperative gamma probe, in order to evaluate the possible use of gamma probe for this purpose. At first a preliminary study of feasibility was carried out using a neck phantom to verify equipment efficiency with known activities of {sup 131} I. Henceforth, work data from 12 patients undergone studies of thyroid uptakes were evaluated, 24 hours after oral administration of 370 kBq of {sup 131} I. The maximum difference observed between the values obtained with both equipment was 60%, which demonstrated the feasibility of the proposed protocol and made clear that gamma probe can be useful for thyroid uptake studies. (author)

  13. Use of gamma probe in {sup 131}I thyroid uptake studies; Utilizacao da sonda a cintilacao na captacao de {sup 131}I pela tireoide

    Energy Technology Data Exchange (ETDEWEB)

    Sarmento, Andrea Gondim Leitao

    2002-11-01

    Evaluation of thyroid uptake by administration of radioactive iodine is a well-defined procedure to assess patient thyroid function. In general, nuclear medicine institutions use gamma cameras coupled to pinhole collimators to perform uptake studies. With the growing use of intraoperative gamma probes in the radioguided surgical techniques, several institutions are purchasing this new and portable equipment, which can technically be also employed to assess patient's thyroid function, permitting further other applications of gamma cameras. The aim of the study was to compare thyroid uptake trails carried out with both gamma camera and intraoperative gamma probe, in order to evaluate the possible use of gamma probe for this purpose. At first a preliminary study of feasibility was carried out using a neck phantom to verify equipment efficiency with known activities of {sup 131} I. Henceforth, work data from 12 patients undergone studies of thyroid uptakes were evaluated, 24 hours after oral administration of 370 kBq of {sup 131} I. The maximum difference observed between the values obtained with both equipment was 60%, which demonstrated the feasibility of the proposed protocol and made clear that gamma probe can be useful for thyroid uptake studies. (author)

  14. Searches for Particle Dark Matter with gamma-rays.

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    In this contribution I review the present status and discuss some prospects for indirect detection of dark matter with gamma-rays. Thanks to the Fermi Large Area Telescope, searches in gamma-rays have reached sensitivities that allow to probe the most interesting parameter space of the weakly interacting massive particles (WIMP) paradigm. This gain in sensitivity is naturally accompanied by a number of detection claims or indications, the most recent being the claim of a line feature at a dark matter particle mass of ∼ 130 GeV at the Galactic Centre, a claim which requires confirmation from the Fermi-LAT collaboration and other experiments, for example HESS II or the planned Gamma-400 satellite. Predictions for the next generation air Cherenkov telescope, Cherenkov Telescope Array (CTA), together with forecasts on future Fermi-LAT constraints arrive at the exciting possibility that the cosmological benchmark cross-section could be probed from masses of a few GeV to a few TeV. Consequently, non-detection wou...

  15. Feasibility of a wireless gammar probe in radioguided surgery

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hye Min; Kim, Jeong Ho; Park, Chan Jong; Joo, Koan Sik [Dept. of Physics, University of Myongji, Seoul (Korea, Republic of)

    2016-04-15

    Nuclear medicine is divided into two major domains: diagnosis and therapy. Nuclear medicine diagnostic procedures are used for determining and evaluating the physiological, chemical, endocrinal, and metabolic conditions of organs or tissues. Tumors can be diagnosed based on the images provided by the associated machinery; after diagnosis, sometimes these tumors can be surgically removed. Currently, to help guide the surgeon to the exact location of the tumor site, the use of intraoperative probes has steadily gained popularity. These probes allow the physician to locate the tumor on the basis of the higher uptake of the preoperatively injected radio pharmaceutical within the site, as compared to the surrounding tissue. Direct detection offers very good energy resolution, but the detection efficiency is low; on the other hand, indirect detection presents high efficiency and low energy resolution. For this reason, the use of both detectors is recommended for obtaining an accurate localization of the diagnostic and therapeutic fields. In the literature, there are several works that aim to develop a suitable probe that presents such characteristics (i.e., good resolution, high detection efficiency, as well as the capacity for miniaturization). In this study, a wireless gamma probe is designed for the detection of tumors of the tissue surface using a silicon photomultiplier (SiPM) and a cerium-doped gadolinium aluminum gallium garnet (Ce:GAGG) scintillator. Our experiments demonstrate the feasibility of wireless diagnostics, as well as the suitable energy resolution and spatial resolution. The system developed based on the results of this study is expected to perform intraoperative or diagnostic evaluations of residual lesions (or the absence thereof) and its quantitative distribution in the affected area, thus contributing to wireless diagnostics and screening systems.

  16. Handheld real-time volumetric 3-D gamma-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Haefner, Andrew, E-mail: ahaefner@lbl.gov [Lawrence Berkeley National Lab – Applied Nuclear Physics, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Barnowski, Ross [Department of Nuclear Engineering, UC Berkeley, 4155 Etcheverry Hall, MC 1730, Berkeley, CA 94720 (United States); Luke, Paul; Amman, Mark [Lawrence Berkeley National Lab – Applied Nuclear Physics, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Vetter, Kai [Department of Nuclear Engineering, UC Berkeley, 4155 Etcheverry Hall, MC 1730, Berkeley, CA 94720 (United States); Lawrence Berkeley National Lab – Applied Nuclear Physics, 1 Cyclotron Road, Berkeley, CA 94720 (United States)

    2017-06-11

    This paper presents the concept of real-time fusion of gamma-ray imaging and visual scene data for a hand-held mobile Compton imaging system in 3-D. The ability to obtain and integrate both gamma-ray and scene data from a mobile platform enables improved capabilities in the localization and mapping of radioactive materials. This not only enhances the ability to localize these materials, but it also provides important contextual information of the scene which once acquired can be reviewed and further analyzed subsequently. To demonstrate these concepts, the high-efficiency multimode imager (HEMI) is used in a hand-portable implementation in combination with a Microsoft Kinect sensor. This sensor, in conjunction with open-source software, provides the ability to create a 3-D model of the scene and to track the position and orientation of HEMI in real-time. By combining the gamma-ray data and visual data, accurate 3-D maps of gamma-ray sources are produced in real-time. This approach is extended to map the location of radioactive materials within objects with unknown geometry.

  17. Optimization of the extent of surgical treatment in patients with stage I in cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chernyshova, A. L.; Lyapunov, A. Yu., E-mail: Lyapunov1720.90@mail.ru [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation); Kolomiets, L. A. [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation); Siberian State Medical University, Moskovsky Trakt 2, Tomsk, 634050 (Russian Federation); Sinilkin, I. G.; Chernov, V. I. [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation); Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation)

    2016-08-02

    The study included 26 patients with FIGO stage Ia1–Ib1 cervical cancer who underwent fertility-sparing surgery (transabdominaltrachelectomy). To visualize sentinel lymph nodes, lymphoscintigraphy with injection of 99mTc-labelled nanocolloid was performed the day before surgery. Intraoperative identification of sentinel lymph nodes using hand-held gamma probe was carried out to determine the radioactive counts over the draining lymph node basin. The sentinel lymph node detection in cervical cancer patients contributes to the accurate clinical assessment of the pelvic lymph node status, precise staging of the disease and tailoring of surgical treatment to individual patient.

  18. A novel hand-type detection technique with fingerprint sensor

    Science.gov (United States)

    Abe, Narishige; Shinzaki, Takashi

    2013-05-01

    In large-scale biometric authentication systems such as the US-Visit (USA), a 10-fingerprints scanner which simultaneously captures four fingerprints is used. In traditional systems, specific hand-types (left or right) are indicated, but it is difficult to detect hand-type due to the hand rotation and the opening and closing of fingers. In this paper, we evaluated features that were extracted from hand images (which were captured by a general optical scanner) that are considered to be effective for detecting hand-type. Furthermore, we extended the knowledge to real fingerprint images, and evaluated the accuracy with which it detects hand-type. We obtained an accuracy of about 80% with only three fingers (index, middle, ring finger).

  19. Unlabeled probes for the detection and typing of herpes simplex virus.

    Science.gov (United States)

    Dames, Shale; Pattison, David C; Bromley, L Kathryn; Wittwer, Carl T; Voelkerding, Karl V

    2007-10-01

    Unlabeled probe detection with a double-stranded DNA (dsDNA) binding dye is one method to detect and confirm target amplification after PCR. Unlabeled probes and amplicon melting have been used to detect small deletions and single-nucleotide polymorphisms in assays where template is in abundance. Unlabeled probes have not been applied to low-level target detection, however. Herpes simplex virus (HSV) was chosen as a model to compare the unlabeled probe method to an in-house reference assay using dual-labeled, minor groove binding probes. A saturating dsDNA dye (LCGreen Plus) was used for real-time PCR. HSV-1, HSV-2, and an internal control were differentiated by PCR amplicon and unlabeled probe melting analysis after PCR. The unlabeled probe technique displayed 98% concordance with the reference assay for the detection of HSV from a variety of archived clinical samples (n = 182). HSV typing using unlabeled probes was 99% concordant (n = 104) to sequenced clinical samples and allowed for the detection of sequence polymorphisms in the amplicon and under the probe. Unlabeled probes and amplicon melting can be used to detect and genotype as few as 10 copies of target per reaction, restricted only by stochastic limitations. The use of unlabeled probes provides an attractive alternative to conventional fluorescence-labeled, probe-based assays for genotyping and detection of HSV and might be useful for other low-copy targets where typing is informative.

  20. Portable gamma and thermal neutron probe using a {sup 6}LiI(Eu) crystal

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, Clemente J.G.; Araujo, Geraldo P.; Milian, Felix M.; Barbosa, Jurandir C.; Garcia, Fermin [Universidade Estadual de Santa Cruz (UESC), Ilheus, BA (Brazil). Centro de Pesquisas em Ciencias e Tecnologias das Radiacoes (CPqCTR); Oliveira, Arno H.; Silva, Mario R.S.; Penna, Rodrigo [Universidade Federal de Minas Gerais (DEN-UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear

    2011-07-01

    Europium-activated lithium-6 iodide is a scintillator used for gamma and neutron counting. A portable detection system was built based on this scintillator. This system has three modules: the scintillator, a 10 m liquid light guide, and a Hamamatsu photon counting head H9319 used as a light pulse digitizer. Data transfer, measurement time and other necessary adjustment can be controlled by software from the PC through the RS-232C interface. The scintillator, a crystal of {sup 6}LiI(Eu), is a small cylinder with 3 mm diameter and 40 mm length completely sealed in an aluminum tube coupled to the light guide. The small size of the scintillator increases the neutron/gamma count ratio, since 2 to 3 mm of thickness of this crystal absorbs all thermal neutrons. Intensities of X and gamma rays, and thermal neutrons can be recorded for time intervals of 10 ms to 1 s storing up to 10000 countings. The system was calibrated for measuring radiation doses for validating numerical models in dosimetry. Two characteristic reinforce this application, measurements can be done at several meters away from the radiation source and also inside of water. In addition, it was used to build nuclear probes based on Compton scattering or neutron moderation in porous media by attaching an AmBe source to the top of the aluminum tube. Tests were done to determine the reproducibility of counting rates. Background counting was measured at several temperatures to verify the influence of dark current of PMT. Sealed AmBe, low activity Am, and X rays sources were used for studies of radiation counting statistics. X rays apparatus was used to correlate counting rates measured with the {sup 6}LiI(Eu) detection system and doses measured with an ionization chamber at several distances from the X ray source. (author)

  1. [Sentinel node detection using optonuclear probe (gamma and fluorescence) after green indocyanine and radio-isotope injections].

    Science.gov (United States)

    Poumellec, M-A; Dejode, M; Figl, A; Darcourt, J; Haudebourg, J; Sabah, Y; Voury, A; Martaens, A; Barranger, E

    2016-04-01

    Assess the biopsy's feasibility of the sentinel lymph node biopsy (SLNB) using optonuclear probe after of indocyanine green (ICG) and radio-isotope (RI) injections. Twenty-one patients with a localized breast cancer and unsuspicious axillary nodes underwent a SLNB after both injections of ICG and radio-isotope. One or more SLN were identified on the 21 patients (identification rate of 100%). The median number SLN was 2 (1-3). Twenty SLN were both radio-actives and fluorescents (54.1%), 11 fluorescent only (29.7%) and 6 were only radio-actives (16.2%). Seven patients had a metastatic SLN (8 SLN overall). Among them, only one had a micrometastasic SLN, 5 others had a macrometastatic SLN and one patient had two macrometastatic SLNs. Among the 8 metastatic SLN, 5 were both fluorescent and radioactive, 2 were only fluorescent and 1 was only radioactive. Detection SLN using optonuclear probe after indocyanine green and radio-isotope injections is effective and could be, after validation by randomized trial, a reliable alternative to the blue dye injection for teams who consider that combined detection as the reference. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  2. Single isotopic probe for gastro-esophageal reflux diagnosis in children

    International Nuclear Information System (INIS)

    Maurel, G.; Le Moing, G.; Mensch, B.

    1987-01-01

    Gastro-esophageal reflux (G.E.R.) in children has been implicated in various recurring respiratory diseases. Several techniques including oesophageal pH testing and scintigraphy have been devised to detect and quantify G.E.R. Limitations have been found for each test: short duration with gamma-camera and restricted acceptability of the pH probe by children. A single isotopic probe was designed for a non-invasive screening test of G.E.R. in infants. This device was checked by comparison with oesophageal scintigraphy using a gamma camera. Only 1 discrepancy was detected in 19 reflux episodes. This method, using a relatively inexpensive detector and data acquisition module, seems to be well accepted by children, and may be associated with a pH probe for GER diagnosis. (orig.)

  3. Design and Development of Hand and Foot Contamination Monitor

    Directory of Open Access Journals (Sweden)

    F. Akter

    2014-08-01

    Full Text Available A hand and foot contamination monitor is a health physics instrument to provide detection and measurement of beta-gamma contamination on the palm of each hand and on the bottom surface of both feet/shoes. There are four channels of detection for two hands and two feet. Four G-M detectors have been used in a single unit to cover the whole area of hand and feet. A regulated high voltage DC power supply (900 V has been designed using the PIC12F675 microcontroller to operate the pancake Geiger-Müller detectors. The reading is displayed on a linearly scaled 0-100 Bq/cm2 analog panel meter. The monitor detects beta–gamma radiation emitted by radioactive materials, and if the detected value exceeds a preset level, the monitor sounds an alarm and displays a reading in the respective panel meter. Indicator lamps are used to show the status of contamination. The performance of the system has been tested by using pulse generator and by flat surface radioactive calibration sources. Electronic linearity, detection efficiency, response to the contamination, calibration factor and percentage of error has been measured. Test results were satisfactory and the present system can be used instead of similar imported instruments.

  4. Cost effective spectral sensor solutions for hand held and field applications

    Science.gov (United States)

    Reetz, Edgar; Correns, Martin; Notni, Gunther

    2015-05-01

    Optical spectroscopy is without doubt one of the most important non-contact measurement principles. It is used in a wide range of applications from bio-medical to industrial fields. One recent trend is to miniaturize spectral sensors to address new areas of application. The most common spectral sensor type is based on diffraction gratings, while other types are based on micro mechanical systems (MEMS) or filter technologies. The authors represent the opinion that there is a potentially wide spread field of applications for spectrometers, but the market limits the range of applications since they cannot keep up with targeted cost requirements for consumer products. The present article explains an alternative approach for miniature multichannel spectrometer to enhance robustness for hand held field applications at a cost efficient price point.

  5. Hip- and knee-strength assessments using a hand-held dynamometer with external belt-fixation are inter-tester reliable

    DEFF Research Database (Denmark)

    Thorborg, Kristian; Bandholm, Thomas; Hölmich, Per

    2013-01-01

    PURPOSE: In football, ice-hockey, and track and field, injuries have been predicted, and hip- and knee-strength deficits quantified using hand-held dynamometry (HHD). However, systematic bias exists when testers of different sex and strength perform the measurements. Belt-fixation of the dynamome...

  6. Cosmic ray nuclei detection in the balloon borne nuclear emulsion gamma ray telescope flight in Australia (GRAINE 2015

    Directory of Open Access Journals (Sweden)

    Iyono Atsushi

    2017-01-01

    Full Text Available Nuclear emulsion plates for studying elementary particle physics as well as cosmic ray physics are very powerful tracking tools with sub-micron spatial resolutions of charged particle trajectories. Even if gamma rays have to be detected, electron-positron pair tracks can provide precise information to reconstruct their direction and energy with high accuracy. Recent developments of emulsion analysis technology can digitally handle almost all tracks recorded in emulsion plates by using the Hyper Track Selector of the OPERA group at NAGOYA University. On the other hand, the potential of time resolutions have been equipped by emulsion multilayer shifter technology in the GRAINE (Gamma Ray Astro-Imager with Nuclear Emulsion experiments, the aims of which are to detect cosmic gamma rays such as the Vela pulsar stellar object by precise emulsion tracking analysis and to study cosmic ray particle interactions and chemical compositions. In this paper, we focus on the subject of cosmic ray nuclei detection in the GRAINE balloon flight experiments launched at Alice Springs, Australia in May 2015.

  7. Photon polarization in $B_s^0 \\to \\phi \\gamma$ decays at the LHCb experiment

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00392538; Martínez Vidal, Fernando

    The Standard Model predicts a predominance of left handed photons emitted in the $b \\to s\\gamma$ interaction, due to the coupling of the $W$ boson to only left handed quarks. Moreso, several Beyond Standard Model theories predict an enhancement of right handed photon emission. A measurement of the photon polairization is therefore a direct probe of New Physics. The photon polarization sensible parameter $\\mathcal{A}^\\Delta$ is measured through a fit to the ratio of untagged time dependent decay rates of $B_s^0 \\to \\phi \\gamma$ over that of $B^0 \\to K^\\ast \\gamma$, the former being sensitive to the parameter because of its non-negligible decay width difference (Phys.Lett.B664:174-179,2008) and the latter being the control channel due to its kinematical similarities and sixfold larger yield. Using 3 fb$^{-1}$ of data collected at LHCb during 2011 and 2012 at centre of mass energies of 7 and 8 TeV, respectively, 4200 $B_s^0 \\to \\phi \\gamma$ and 25700 $B^0 \\to K^\\ast \\gamma$ events are reconstructed. The selecti...

  8. Assessment of the geometric coincidence of neutron and gamma probe measurements with solo 40 and CPN 501 B

    International Nuclear Information System (INIS)

    Valles, V.; Guiresse, M.; Tcherbakov, R.

    1989-01-01

    The distance between the gamma and neutron probe measurement centres was determined for the Nardeux Solo 40 and CPN 501 B probes. The centre of the spheres of influence was localized using a water-air interface constituted by a metal cylinder filled with 200 liters of water. For Solo 40, the discrepancy between the two measurement centres was 6 cm. This shift value, which is quite acceptable, does not require any correction for these measurements, even when the soil is heterogeneous. For CNP 501 B, the discrepancy between the neutron and gamma measurement was 11 cm, i.e. nearly twice the value observed with Solo 40. In soils with a marked vertical heterogeneity, it therefore seems preferable to operate a 11 cm shift of the probe between the moisture and density measurements [fr

  9. Gadolinium-Based GaN for Neutron Detection with Gamma Discrimination

    Science.gov (United States)

    2016-06-01

    Gadolinium-Based GaN for Neutron Detection with Gamma Discrimination Distribution Statement A. Approved for public release; distribution is...Final Technical Report BRBAA08-Per5-Y-1-2-0030 Title: “Gadolinium-Based GaN for Neutron Detection with Gamma Discrimination ” Grant...Analysis  .............................................................................................  23   6.   Gamma-ray Discrimination

  10. Comparison of two types of scintillation probe for moisture density gauge

    International Nuclear Information System (INIS)

    Machaj, B.

    1974-01-01

    Investigations of pulse shape discrimination scintillation probe, and amplitude discrimination probe as a detector for moisutre density gauge have been carried out. It was found that sandwich scintillator consisting of NE-421 + NE-102A was the best for pulse shape discrimination probe for thermal neutrons and gamma radiation detection. Similarly LiJ(Eu) crystal was the best for amplitude discrimination probe. The amplitude discrimination probe with LiJ(Eu) comparing to pulse shape discrimination probe with sandwich scintillator, provides approximately two times higher thermal neutron detection efficiency and higher count rate stability. It is considered therefore more suitable as the detector for moisture density gauge. (author)

  11. Lymphoscintigraphy with intraoperative gamma probe sentinel node detection: clinical impact in patients with head and neck melanomas

    International Nuclear Information System (INIS)

    Maccauro, M.; Villano, C.; Aliberti, G.; Ferrani, L.; Castellani, M.R.; Bombardieri, E.; Patuzzo, R.; Santinami, M.; Tshering, D.

    2005-01-01

    Aim. The aims of this paper were to evaluate the clinical relevance of lymphoscintigraphy with intraoperative gamma-probe detection in identifying sentinel nodes (SNs) and to study the prognostic value of SN biopsy in head and neck melanoma patients. Methods. Sixty-one patients had lymphoscintigraphy with intradermal injections of 99m Tc-Nanocoll (40 MBq), 24 h before surgery. Tumor-positive SNs patients underwent total lymph node dissection Postoperative histological examination was performed. Patients were followed up for 1 to 5 years (median 3 years). The tumor relapses and the overall survival were evaluated by means of statistical methods. Results. Lymphoscintigraphy showed lymphatic distribution to more than one basin in 45 patients (74%), in 15 patients one basin was visualized and no basin in 1 patient. In 41 patients the SN was negative for metastases, while in 20 was positive. In a high percentage of patients (30%), metastatic involvement occurred in more than one lymph node basin. During follow-up in the negative SN group, 40 patients remained disease free and 1 relapsed. In the positive SN group, 10 patients remained disease free and 10 relapsed. Recurrence time ranged from 6 to 11 months. The overall survival of the SNs negative group was significantly higher than the positive SN group. Conclusion. This approach was able to distinguish: a) patients with tumor-negative SNs with a favorable clinical course (98% did not relapse, P<0.001); b) patients with tumor-positive SNs with a high rate of tumor relapse (50%, P<0.001). Therefore SN biopsy may give information about prognosis in head and neck melanoma patients

  12. Visual Search and Target Cueing: A Comparison of Head-Mounted Versus Hand-Held Displays on the Allocation of Visual Attention

    National Research Council Canada - National Science Library

    Yeh, Michelle; Wickens, Christopher D

    1998-01-01

    We conducted a study to examine the effects of target cueing and conformality with a hand-held or head-mounted display to determine their effects on visual search tasks requiring focused and divided attention...

  13. The Scanning Theremin Microscope: A Model Scanning Probe Instrument for Hands-On Activities

    Science.gov (United States)

    Quardokus, Rebecca C.; Wasio, Natalie A.; Kandel, S. Alex

    2014-01-01

    A model scanning probe microscope, designed using similar principles of operation to research instruments, is described. Proximity sensing is done using a capacitance probe, and a mechanical linkage is used to scan this probe across surfaces. The signal is transduced as an audio tone using a heterodyne detection circuit analogous to that used in…

  14. Plastic Gamma Sensors: An Application in Detection of Radioisotopes

    International Nuclear Information System (INIS)

    Mukhopadhyay, S.

    2003-01-01

    A brief survey of plastic scintillators for various radiation measurement applications is presented here. The utility of plastic scintillators for practical applications such as gamma radiation monitoring, real-time radioisotope detection and screening is evaluated in laboratory and field measurements. This study also reports results of Monte Carlo-type predictive responses of common plastic scintillators in gamma and neutron radiation fields. Small-size plastic detectors are evaluated for static and dynamic gamma-ray detection sensitivity of selected radiation sources

  15. Sensitivity of self-powered detector probes to electron and gamma-ray fields

    International Nuclear Information System (INIS)

    Lone, M.A.; Wong, P.Y.

    1995-01-01

    A self-powered detector (SPD) is a simple, passive device that consists of a coaxial probe with a metallic outer sleeve, a mineral oxide insulating layer, and a metallic inner core. SPD's are used in nuclear reactors to monitor neutron and gamma fields. Responses of SPD's to electrons and γ-rays of various energies were investigated with Monte Carlo simulations. Transmission filters were studied for the design of threshold SPD probes used for online monitoring of the energy spectrum of high-power industrial electron accelerator beams. Filters were also investigated for the enhancement of γ-ray sensitivity of an SPD placed in a mixed electron and γ-ray field. (author). 30 refs., 1 tab., 8 figs

  16. Protein recognition by a pattern-generating fluorescent molecular probe

    Science.gov (United States)

    Pode, Zohar; Peri-Naor, Ronny; Georgeson, Joseph M.; Ilani, Tal; Kiss, Vladimir; Unger, Tamar; Markus, Barak; Barr, Haim M.; Motiei, Leila; Margulies, David

    2017-12-01

    Fluorescent molecular probes have become valuable tools in protein research; however, the current methods for using these probes are less suitable for analysing specific populations of proteins in their native environment. In this study, we address this gap by developing a unimolecular fluorescent probe that combines the properties of small-molecule-based probes and cross-reactive sensor arrays (the so-called chemical 'noses/tongues'). On the one hand, the probe can detect different proteins by generating unique identification (ID) patterns, akin to cross-reactive arrays. On the other hand, its unimolecular scaffold and selective binding enable this ID-generating probe to identify combinations of specific protein families within complex mixtures and to discriminate among isoforms in living cells, where macroscopic arrays cannot access. The ability to recycle the molecular device and use it to track several binding interactions simultaneously further demonstrates how this approach could expand the fluorescent toolbox currently used to detect and image proteins.

  17. Investigation of LaBr3:Ce probe for gamma-ray spectroscopy and dosimetry

    Science.gov (United States)

    Maghraby, Ahmed M.; Alzimami, K. S.; Alkhorayef, M. A.; Alsafi, K. G.; Ma, A.; Alfuraih, A. A.; Alghamdi, A. A.; Spyrou, N. M.

    2014-02-01

    The main thrust of this work is the investigation of performance of relatively new commercial LaBr3:Ce probe (Inspector 1000™ with LaBr3:Ce crystal) for gamma-ray spectroscopy and dosimetry measurements in comparison to LaCl3:Ce and NaI:Tl scintillators. The crystals were irradiated by a wide range of energies (57Co, 22Na, 18F, 137Cs and 60Co). The study involved recording of detected spectra and measurement of energy resolution, photopeak efficiency, internal radioactivity measurements as well as dose rate. The Monte Carlo package, Geant4 Application for Tomographic Emission (GATE) was used to validate the experiments. Overall results showed very good agreement between the measurements and the simulations. The LaBr3:Ce crystal has excellent energy resolution, energy resolutions of (3.37±0.05)% and (2.98±0.07)% for a 137Cs 662 keV and a 60Co 1332 keV gamma-ray point sources respectively, were recorded. The disadvantage of the lanthanum halide scintillators is their internal radioactivity. Inspector 1000™ with LaBr3:Ce scintillator has shown an accurate and quick dose measurements at Positron Emission Tomography (PET) Units which allows accurate assessment of the radiation dose received by staff members compared to the use of electronic personal dosimeters (EPD).

  18. 3D indoor modeling using a hand-held embedded system with multiple laser range scanners

    Science.gov (United States)

    Hu, Shaoxing; Wang, Duhu; Xu, Shike

    2016-10-01

    Accurate three-dimensional perception is a key technology for many engineering applications, including mobile mapping, obstacle detection and virtual reality. In this article, we present a hand-held embedded system designed for constructing 3D representation of structured indoor environments. Different from traditional vehicle-borne mobile mapping methods, the system presented here is capable of efficiently acquiring 3D data while an operator carrying the device traverses through the site. It consists of a simultaneous localization and mapping(SLAM) module, a 3D attitude estimate module and a point cloud processing module. The SLAM is based on a scan matching approach using a modern LIDAR system, and the 3D attitude estimate is generated by a navigation filter using inertial sensors. The hardware comprises three 2D time-flight laser range finders and an inertial measurement unit(IMU). All the sensors are rigidly mounted on a body frame. The algorithms are developed on the frame of robot operating system(ROS). The 3D model is constructed using the point cloud library(PCL). Multiple datasets have shown robust performance of the presented system in indoor scenarios.

  19. Detection of gamma rays using scintillation optical fibers

    International Nuclear Information System (INIS)

    Park, J. W.; Hong, S. B.

    2002-01-01

    Scintillating optical fibers have several advantages over other conventional materials used for radiation detection. We have used glass and plastic scintillating fibers to detect gamma rays emitted from 60 Co and 137 Cs, and beta rays from 90 Sr. The sensors are constructed of single strand or multi-strand fibers of 1 mm diameter. The glass scintillating fiber used contains cerium-activated lithium-silicate as scintillating material and the plastic scintillating fiber used is Bicron model BCF-12. In this paper, we report the pulse-height spectra obtained by both sensor types, and analyze them in the aspect of their usability for radiation detectors. Our investigation suggests that the glass fiber can be used to develop gamma ray detectors which will function in high and low gamma ray flux environments. Use of the sensor for the beta ray detection was not satisfactory. The plastic fiber sensor did not work satisfactorily for the weak gamma sources, but did produce somewhat promising results. The scintillating plastic fiber offers some feasibility as beta ray sensor material

  20. Millisecond Pulsars at Gamma-Ray Energies: Fermi Detections and Implications

    Science.gov (United States)

    Harding, Alice K.

    2011-01-01

    The Fermi Gamma-Ray Space Telescope has revolutionized the study of pulsar physics with the discovery of new populations of radio quiet and millisecond gamma-ray pulsars. The Fermi Large Area Telescope has so far discovered approx.20 new gamma-ray millisecond pulsars (MSPs) by both folding at periods of known radio MSPs or by detecting them as gamma-ray sources that are followed up by radio pulsar searches. The second method has resulted in a phenomenally successful synergy, with -30 new radio MSPs (to date) having been discovered at Fermi unidentified source locations and the gamma-ray pulsations having then been detected in a number of these using the radio timing solutions. Many of the newly discovered MSPs may be suitable for addition to the collection of very stable MSPs used for gravitational wave detection. Detection of such a large number of MSPs was surprising, given that most have relatively low spin-down luminosity and surface field strength. I will discuss their properties and the implications for pulsar particle acceleration and emission, as well as their potential contribution to gamma-ray backgrounds and Galactic cosmic rays.

  1. Detection of Fatigue Cracks at Rivets with Self-Nulling Probe

    Science.gov (United States)

    Wincheski, Buzz; Fulton, Jim; Nath, Shridhar; Namkung, Min

    1994-01-01

    A new eddy current probe developed at NASA Langley Research Center has been used to detect small cracks at rivets in aircraft lap splices [1]. The device has earlier been used to detect isolated fatigue cracks with a minimum detectable flaw size of roughly 1/2 to 1/3 the diameter of the probe [2]. The present work shows that the detectable flaw size for cracks originating at rivets can be greatly improved upon from that of isolated flaws. The use of a rotating probe method combined with spatial filtering has been used to detect 0.18 cm EDM notches, as measured from the rivet shank, with a 1.27 cm diameter probe and to detect flaws buried under the rivet head, down to a length of 0.076 cm, using a 0.32 cm diameter probe. The Self-Nulling Electromagnetic Flaw Detector induces a high density eddy current ring in the sample under test. A ferromagnetic flux focusing lens is incorporated such that in the absence of any inhomogeneities in the material under test only a minimal magnetic field will reach the interior of the probe. A magnetometer (pickup coil) located in the center of the probe therefore registers a null voltage in the absence of material defects. When a fatigue crack or other discontinuity is present in the test article the path of the eddy currents in the material is changed. The magnetic field associated with these eddy currents then enter into the interior of the probe, producing a large output voltage across the pickup coil leads. Further

  2. A radioactive particle detection system for the Maralinga rehabilitation project

    International Nuclear Information System (INIS)

    Martin, L.J.; Baylis, S.H.

    1998-01-01

    Following the cessation of British nuclear testing at Maralinga, several sites were left contaminated with plutonium in various forms over areas of many square kilometres. The contamination included 239 Pu and 241 Am together with other isotopes of plutonium, and was in the form of fine dust, discrete particles and contaminated fragments of metals, plastics and ceramics. Following a government decision to rehabilitate the area to a standard suitable for re-occupation by the traditional owners, the Maralinga Tjarutja, an expert committee, MARTAC, was convened to advise the Department of Primary Industries and Energy about suitable methods and standards for the cleanup. Criteria set by MARTAC required the removal of all discrete particles of contamination exceeding 100 kBq of 241 Am and imposed limits on the numbers of particles exceeding 20 kBq. A detection system was required which could detect any radioactive particles exceeding criteria and, following rehabilitation, verify that none remained. The most useful indicator of contamination was the 60 keV gamma-ray from 241 Am. The system was fitted to a four wheel drive utility vehicle, and was based on four thin-crystal, sodium iodide detectors of 12.5 cm diameter held 30 cm above ground level. Electronic components from off-the-shelf hand-held ratemeters were used to provide the high voltage supply, amplifier and single channel analyser in a ruggedised form of proven reliability. The combined use of thin crystal detectors and single channel analyser allowed a significant reduction in background count rates while maintaining the efficiency for detection of the 60 keV gamma-ray. To allow efficient and reliable coverage, the vehicle was fitted with a high-resolution speedometer to allow the proper speed to be maintained, and a mapping display, based on the GPS system, which showed the previous path of the vehicle and boundary of the area to be scanned. Whenever a radioactive particle was detected, its coordinates were

  3. Detection circuit for gamma-ray burst

    International Nuclear Information System (INIS)

    Murakami, Hiroyuki; Yamagami, Takamasa; Mori, Kunishiro; Uchiyama, Sadayuki.

    1982-01-01

    A new gamma-ray burst detection system is described. The system was developed as an environmental monitor of an accelerator, and can be used as the burst detection system. The system detects the arrival time of burst. The difference between the arrival times detected at different places will give information on the burst source. The frequency of detecting false burst was estimated, and the detection limit under the estimated frequency of false burst was also calculated. Decision whether the signal is false or true burst was made by the statistical treatment. (Kato, T.)

  4. Advanced digital counting rate meter for gamma ray logging

    International Nuclear Information System (INIS)

    Kannan, S.; Meenakshi Sundari, A.; Rai, A.K.

    2013-01-01

    A compact, hand held controller based Advanced Digital Count Rate Meter (ADCRM) as a replacement of bulky Count Rate (analog) Meters (SBL-2A) was designed, developed and fabricated to carry out Gamma-Ray borehole logging with Geiger Muller (GM) tubes and Scintillation (SC) detectors. In the hardware the functionality of analog meter simulation, digital counting of gamma events and auto reference adjustment to use different length of armour cable winches were implemented. The in-built software evaluates grade in ppm and at the end of logging, the reports are prepared automatically. ADCRM was developed in-house to assist the uranium mineral exploration in AMD. (author)

  5. Radiation Protection Considerations about gamma probe-guided intraoperative sentinel lymph node surgery

    International Nuclear Information System (INIS)

    Rodriguez, C.; Jimenez-Hoyuela Garcia, J. L.; Rebollo Aguirre, J. M.; Custodio, A.

    2002-01-01

    The sentinel node concept is based on the sequential dissemination hypothesis. According to it, there's a lymph node (named sentinel node) which is the first receiving cancer cells metastasizing from a primary tumor. Further, others nodes sequentially located might be affected. Surgical performance for several types of cancer includes the complete removal of the tumor and a complete local lymph node dissection (LND). so removing and analyzing the sentinel node may avoid the complete LND. To locate the sentinel node, it's usual the local administration (intradermal injection) of a radiopharmaceutical Tc-99, sulfur colloid (activity about 1 mCi( several hours prior to surgery, and using an intraoperative gamma probe very sensitive to the gamma radiation. Although the activity is injected by the Nuclear Medicine staff, and be exposed to the gamma radiation. In this study we estimated maximum possible doses that would be received by personnel (surgical staff during surgery and pathologists during lumpectomy of the sentinel node). For the surgical staff, to avoid dose errors due to the very low residual activities and not to interfere with the personnel in the surgery room, we estimated doses by taking into account only the physical decay of Tc99m injected. for the pathologists, we estimated the residual activity in the sentinel node with the gamma probe. The highest effective dose rate found was to the surgeon (o,44 μSv/h, respectively. so a surgeon could perform 407 hours/yr, and a pathologist 1717 hours/yr, dedicated exclusively to sentinel node biopsy, before being classified as professionally exposed to radiation, and 4070 and 17170 hours per year, respectively, to surpass the annual limits (national regulations of the European Communities). In short, radiation doses to clinical staff involved in the technique are low, and in normal conditions, by establishing appropriate procedures (precautions during surgery, during manipulation surgical specimen...) control

  6. Deoxyribonucleic Acid Probes Analyses for the Detection of Periodontal Pathogens.

    Science.gov (United States)

    Al Yahfoufi, Zoubeida; Hadchiti, Wahib; Berberi, Antoine

    2015-09-01

    In clinical microbiology several techniques have been used to identify bacteria. Recently, Deoxyribonucleic acid (DNA)-based techniques have been introduced to detect human microbial pathogens in periodontal diseases. Deoxyribonucleic acid probes can detect bacteria at a very low level if we compared with the culture methods. These probes have shown rapid and cost-effective microbial diagnosis, good sensitivity and specificity for some periodontal pathogens in cases of severe periodontitis. Eighty-five patients were recruited for the study. Twenty-one subjects ranging between 22 and 48 years of age fulfilled the inclusion and exclusion criteria. Seventy-eight samples became available for DNA probe analysis from the deepest pockets in each quadrant. All 21 patients showed positive results for Prevotella intermedia; also, Prevotella gingivalis was identified in 19 subjects, Aggregatibacter actinomycetemcomitans in 6 subjects. P. intermedia was diagnosed positive in 82% of the subgingival samples taken, 79% for P. gingivalis, and 23% for A. actinomycetemcomitans. This study shows a high frequency of putative periodontal pathogens by using DNA probe technology, which is semi-quantitative in this study. Deoxyribonucleic acid probes can detect bacteria at very low level about 10(3) which is below the detection level of culture methods. The detection threshold of cultural methods. The three types of bacteria can be detected rapidly with high sensitivity by using the DNA probe by general practitioners, and thus can help in the diagnosis process and the treatment.

  7. Status report on the TSA Systems, Ltd., MCA465 gamma-ray confirmation instrument

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Rutherford, D.A.

    1994-01-01

    The TSA Systems, Ltd., MCA465 is hand-portable, low resolution, gamma-ray instrument for confirming special nuclear materials (SNM) and related applications. The instrument evolved from earlier TSA Systems hand-held instruments, and, since its inception in 1991, it has been undergoing cycles of evaluation and then repair or redesign to correct problems. Through the efforts of Los Alamos, Rocky Flats, and TSA Systems, the MCA465 now has achieved commendable progress toward achieving quality performance as a rapid confirmation tool for SNM

  8. Dark matter annihilation into right-handed neutrinos and the galactic center gamma-ray excess

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yi-Lei [Center for High Energy Physics, Peking University,Beijing 100871 (China); Zhu, Shou-hua [Center for High Energy Physics, Peking University,Beijing 100871 (China); Institute of Theoretical Physics State Key Laboratory of Nuclear Physics and Technology,Peking University, Beijing 100871 (China); Collaborative Innovation Center of Quantum Matter,Beijing 100871 (China)

    2016-03-08

    In this paper, we will discuss a specific case that the dark matter particles annihilate into right-handed neutrinos. We calculate the predicted gamma-ray excess from the galactic center and compare our results with the data from the Fermi-LAT. An approximately 10–60 GeV right-handed neutrino with heavier dark matter particle can perfectly explain the observed spectrum. The annihilation cross section 〈σv〉 falls within the range 0.5–4×10{sup −26} cm{sup 3}/s, which is roughly compatible with the WIMP annihilation cross section.

  9. Sentinel lymph node (Sln) detection in vulvar cancer

    International Nuclear Information System (INIS)

    Grimm, J.; Mende, T.; Lantzsch, T.; Seliger, G.; Koelbl, H.; Buchmann, J.

    2002-01-01

    Full text: The purpose of the study is to verify the feasibility of the sentinel lymph node (SLN) procedure in patients with evidence of vulva cancer. We studied 13 women with early stage (T1/T2) carcinoma of the vulva. One day before surgery a lymphoscintigraphy was done. We injected intradermally an average 76 MBq of 99m Tc-labelled human colloides (Albu-Res(r) in 0.4-0.6 ml NaCI at 4 locations round the tumor regarding the midline. Because of the large particles the colloid was filtered before to obtain the small particle fraction between 200-450 nm. Immediately alter injection a dynamic scintigraphy was performed with 28 images, 1 minute per frame. Additional we made static images, 5 minutes per image, 30 and 120 minutes after injection. The location of the SLN was marked on the skin. The SLN was intraoperatively identified using a hand-held gamma probe. In every case a complete inguino-femoral lymph node dissection was done. In all cases we could show one or more (on average 3) SLN by means of lymphoscintigraphy and in 11/13 cases we could detect SLN by using the gamma probe. Lymph channels were seen in 7/13 dynamic studies. 4/13 patients had lymph node metastasis in the SLN (3/4 cases only the SLN and in 1/4 cases the SLN and one additional lymph node were positive). We did not found any tumor-positive non-sentinel lymph node in case of tumor-negative SLN. The morbidity after operation of patients with vulva cancer is considerable and related to the groin dissection. The selective SLN-biopsy instead of radical groin dissection is feasible to reduce the morbidity without a loss of staging and prognostic factors. This method should be restricted to patients with early stage vulva cancer with clinically uninvolved lymph nodes. Further studies are needed to evaluate the accuracy and clinical validity of this procedure. (author)

  10. Study of gamma detection capabilities of the REWARD mobile spectroscopic system

    Science.gov (United States)

    Balbuena, J. P.; Baptista, M.; Barros, S.; Dambacher, M.; Disch, C.; Fiederle, M.; Kuehn, S.; Parzefall, U.

    2017-07-01

    REWARD is a novel mobile spectroscopic radiation detector system for Homeland Security applications. The system integrates gamma and neutron detection equipped with wireless communication. A comprehensive simulation study on its gamma detection capabilities in different radioactive scenarios is presented in this work. The gamma detection unit consists of a precise energy resolution system based on two stacked (Cd,Zn)Te sensors working in coincidence sum mode. The volume of each of these CZT sensors is 1 cm3. The investigated energy windows used to determine the detection capabilities of the detector correspond to the gamma emissions from 137Cs and 60Co radioactive sources (662 keV and 1173/1333 keV respectively). Monte Carlo and Technology Computer-Aided Design (TCAD) simulations are combined to determine its sensing capabilities for different radiation sources and estimate the limits of detection of the sensing unit as a function of source activity for several shielding materials.

  11. Influence of climatological and meteorological events on the Cuban environmental gamma background

    International Nuclear Information System (INIS)

    Dominguez Ley, Orlando; Caveda Ramos, Celia; Ramos Viltre, Emma O.; Dominguez Garcia, Adriel; Alonso Abad, Dolores

    2008-01-01

    Full text: A network of environmental radiological surveillance can appropriately respond in case of any radiological anomaly, due to the suitable methodology employed, the equipment used, the automatized detection systems and the data processing. But it is also important to know how the measurements of the different radiological indicators vary with the action of any atmospheric phenomenon. In this work, an analysis of the effects produced on the environmental gamma background in Cuba when acting climatological and meteorological events, has been achieved. Events, such as seasons of severe precipitation, dry seasons, winter and summer, hurricanes and high and low pressures are studied. The measurements were carried out with a gamma probe which is equipped with two Geiger Muller detectors and a temperature sensor. This probe is located at the height of 3.5 m and is exposed to the direct sun rays. We have built hypothesis for explaining some behaviors related to meteorological events, such as hurricanes. However, our theories are not conclusive, since the data obtained from the presence of this kind of phenomena next to the sites of interest was very poor. In this work, we have given explanation to the fluctuation of the measurements achieved of the environmental gamma background, based on the occurrence of some meteorological and climatological events. All this was possible due to a previous study about the influence of the diurnal variation of the temperature over the measurements of the gamma dose rate. On the other hand, the results obtained and the study of the influence of another environmental parameters, will contribute to the alarm levels setting for this radiological indicator according to the season which the measurements are achieved in. (author)

  12. Surface-enhanced Raman scattering based nonfluorescent probe for multiplex DNA detection.

    Science.gov (United States)

    Sun, Lan; Yu, Chenxu; Irudayaraj, Joseph

    2007-06-01

    To provide rapid and accurate detection of DNA markers in a straightforward, inexpensive, and multiplex format, an alternative surface-enhanced Raman scattering based probe was designed and fabricated to covalently attach both DNA probing sequence and nonfluorescent Raman tags to the surface of gold nanoparticles (DNA-AuP-RTag). The intensity of Raman signal of the probes could be controlled through the surface coverage of the nonfluorescent Raman tags (RTags). Detection sensitivity of these probes could be optimized by fine-tuning the amount of DNA molecules and RTags on the probes. Long-term stability of the DNA-AuP-RTag probes was found to be good (over 3 months). Excellent multiplexing capability of the DNA-AuP-RTag scheme was demonstrated by simultaneous identification of up to eight probes in a mixture. Detection of hybridization of single-stranded DNA to its complementary targets was successfully accomplished with a long-term goal to use nonfluorescent RTags in a Raman-based DNA microarray platform.

  13. Reliability of measuring hip abductor strength following total knee arthroplasty using a hand-held dynamometer.

    Science.gov (United States)

    Schache, Margaret B; McClelland, Jodie A; Webster, Kate E

    2016-01-01

    To investigate the test-retest reliability of measuring hip abductor strength in patients with total knee arthroplasty (TKA) using a hand-held dynamometer (HHD) with two different types of resistance: belt and manual resistance. Test-retest reliability of 30 subjects (17 female, 13 male, 71.9 ± 7.4 years old), 9.2 ± 2.7 days post TKA was measured using belt and therapist resistance. Retest reliability was calculated with intra-class coefficients (ICC3,1) and 95% confidence intervals (CI) for both the group average and the individual scores. A paired t-test assessed whether a difference existed between the belt and therapist methods of resistance. ICCs were 0.82 and 0.80 for the belt and therapist resisted methods, respectively. Hip abductor strength increases of 8 N (14%) for belt resisted and 14 N (17%) for therapist resisted measurements of the group average exceeded the 95% CI and may represent real change. For individuals, hip abductor strength increases of 33 N (72%) (belt resisted) and 57 N (79%) (therapist resisted) could be interpreted as real change. Hip abductor strength can be reliably measured using HHD in the clinical setting with the described protocol. Belt resistance demonstrated slightly higher test-retest reliability. Reliable measurement of hip abductor muscle strength in patients with TKA is important to ensure deficiencies are addressed in rehabilitation programs and function is maximized. Hip abductor strength can be reliably measured with a hand-held dynamometer in the clinical setting using manual or belt resistance.

  14. Public List of LAT-Detected Gamma-Ray Pulsars

    Data.gov (United States)

    National Aeronautics and Space Administration — The following is a compilation of all publicly-announced gamma-ray pulsars detected using the Fermi LAT. Each of the detections has been vetted by the LAT team,...

  15. Detection of an intense polychromatic gamma beam modulated at 3000 MHz; Detection d'un faisceau intense de gammas polychromatiques module a 3000 MHz

    Energy Technology Data Exchange (ETDEWEB)

    Beil, H; Veyssiere, A; Daujat, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    This paper presents two methods of detection of a {gamma} beam modulated at very high frequencies. The intense modulated beam is created by means of Bremsstrahlung in a gold-target, the latter having been placed in the emerging electron beam of the Linac at Saclay. A tentative interpretation of the physical phenomena involved in the detection processes is also given. The empirical data agree reasonably well with numerical evaluations based on well established theoretical concepts concerning these phenomena. (authors) [French] Cet article presente deux facons de detecter un faisceau de {gamma} module a haute frequence. Le faisceau intense de {gamma} est cree par l'impact d'electrons (acceleres dans un accelerateur lineaire) sur une cible en or. Une tentative d'interpretation des phenomenes physiques mis en cause dans le processus de detection est donnee et les valeurs experimentales trouvees s'accordent raisonnablement bien avec les valeurs calculees a partir des considerations theoriques des phenomenes. (auteurs)

  16. An embedded system developed for hand held assay used in water monitoring

    Science.gov (United States)

    Wu, Lin; Wang, Jianwei; Ramakrishna, Bharath; Hsueh, Mingkai; Liu, Jonathan; Wu, Qufei; Wu, Chao-Cheng; Cao, Mang; Chang, Chein-I.; Jensen, Janet L.; Jensen, James O.; Knapp, Harlan; Daniel, Robert; Yin, Ray

    2005-11-01

    The US Army Joint Service Agent Water Monitor (JSAWM) program is currently interested in an approach that can implement a hardware- designed device in ticket-based hand-held assay (currently being developed) used for chemical/biological agent detection. This paper presents a preliminary investigation of the proof of concept. Three components are envisioned to accomplish the task. One is the ticket development which has been undertaken by the ANP, Inc. Another component is the software development which has been carried out by the Remote Sensing Signal and Image Processing Laboratory (RSSIPL) at the University of Maryland, Baltimore County (UMBC). A third component is an embedded system development which can be used to drive the UMBC-developed software to analyze the ANP-developed HHA tickets on a small pocket-size device like a PDA. The main focus of this paper is to investigate the third component that is viable and is yet to be explored. In order to facilitate to prove the concept, a flatbed scanner is used to replace a ticket reader to serve as an input device. The Stargate processor board is used as the embedded System with Embedded Linux installed. It is connected to an input device such as scanner as well as output devices such as LCD display or laptop etc. It executes the C-Coded processing program developed for this embedded system and outputs its findings on a display device. The embedded system to be developed and investigated in this paper is the core of a future hardware device. Several issues arising in such an embedded system will be addressed. Finally, the proof-of-concept pilot embedded system will be demonstrated.

  17. Statistical analyses of in-situ and soil-sample measurements for radionuclides in surface soil near the 116-K-2 trench

    International Nuclear Information System (INIS)

    Gilbert, R.O.; Klover, W.J.

    1988-09-01

    Radiation detection surveys are used at the US Department of Energy's Hanford Reservation near Richland, Washington, to determine areas that need posting as radiation zones or to measure dose rates in the field. The relationship between measurements made by Sodium Iodide (NaI) detectors mounted on the mobile Road Monitor vehicle and those made by hand-held GM P-11 probes and Micro-R meters are of particular interest because the Road Monitor can survey land areas in much less time than hand-held detectors. Statistical regression methods are used here to develop simple equations to predict GM P-11 probe gross gamma count-per-minute (cpm) and Micro-R-Meter μR/h measurements on the basis of NaI gross gamma count-per-second (cps) measurements obtained using the Road Monitor. These equations were estimated using data collected near the 116-K-2 Trench in the 100-K area on the Hanford Reservation. Equations are also obtained for estimating upper and lower limits within which the GM P-11 or Micro-R-Meter measurement corresponding to a given NaI Road Monitor measurement at a new location is expected to fall with high probability. An equation and limits for predicting GM P-11 measurements on the basis of Micro-R- Meter measurements is also estimated. Also, we estimate an equation that may be useful for approximating the 90 Sr measurement of a surface soil sample on the basis of a spectroscopy measurement for 137 Cs on that sample. 3 refs., 16 figs., 44 tabs

  18. Comparison of 99mTc-MIBI scanning and sentinel node biopsy in the detection of occult melanoma lymph node metastases

    International Nuclear Information System (INIS)

    Alonso, O.; Lago, G.; Lopes de Amorim, M.C.; Juri, C.; Larre Borges, A.; Martinez, M.; De Boni, D.; Espasandin, J.; Priario, J.

    2002-01-01

    Aim: Sentinel node biopsy (SNB) is a highly accurate technique for detecting occult metastatic disease in the regional lymph nodes. Our group has reported that 99m Tc-MIBI scintigraphy is an imaging technique that can detect clinically undetectable metastases. This prospective study shows preliminary results on the comparison of both techniques for the detection of lymph node invasion. Material and Methods: Twenty-two consecutive patients (15 women, 7 men; mean age, 55 years) with primary melanoma > 1.0 mm thick were enrolled (mean 2.6 mm). Patients underwent 99m Tc-MIBI scintigraphy of regional lymph nodes 1-2 weeks before surgery, acquiring 10-minute planar images with a LFOV gamma camera. A preoperative lymphoscintigraphy using 99m Tc-colloidal (Re) sulphide was performed the day before surgery, using a dose of 74-93 MBq. Radio guided SNB was performed with a hand-held gamma probe. Lymph nodes were examined histologically and immunostained for S-100 and HMB-45. Results: The sentinel node (SN) was identified in 21/22 patients. An average of 1.6 SN/lesion were harvested from melanomas located in the following regions: head and neck (n=3), trunk (n=6), extremities (n=12). All patients with negative SN (n=11) were also negative with MIBI. In 10 cases the SN demonstrated metastatic involvement, whereas 99m Tc-MIBI was positive in 8 of them (80%). In cases with positive SN/negative 99m Tc-MIBI, the pathology report revealed micro metastatic disease. Conclusion: These preliminary results suggest that 99m Tc-MIBI scanning has the potential of selecting a group of patients who might benefit from a selective complete lymphadenectomy

  19. Whole genomic DNA probe for detection of Porphyromonas endodontalis.

    Science.gov (United States)

    Nissan, R; Makkar, S R; Sela, M N; Stevens, R

    2000-04-01

    The purpose of the present study was to develop a DNA probe for Porphyromonas endodontalis. Pure cultures of P. endodontalis were grown in TYP medium, in an anaerobic chamber. DNA was extracted from the P. endodontalis and labeled using the Genius System by Boehringer Mannheim. The labeled P. endodontalis DNA was used in dot-blot hybridization reactions with homologous (P. endodontalis) and unrelated bacterial samples. To determine specificity, strains of 40 other oral bacterial species (e.g. Porphyromonas gingivalis, Porphyromonas asaccharolytica, and Prevotella intermedia) were spotted and reacted with the P. endodontalis DNA probe. None of the panel of 40 oral bacteria hybridized with the P. endodontalis probe, whereas the blot of the homologous organism showed a strong positive reaction. To determine the sensitivity of the probe, dilutions of a P. endodontalis suspension of known concentration were blotted onto a nylon membrane and reacted with the probe. The results of our investigation indicate that the DNA probe that we have prepared specifically detects only P. endodontalis and can detect at least 3 x 10(4) cells.

  20. Clinical assessment of hip strength using a hand-held dynamometer is reliable

    DEFF Research Database (Denmark)

    Thorborg, K; Petersen, J; Magnusson, S P

    2010-01-01

    rotation (ER), internal rotation (IR), flexion (FLEX) and extension (EXT) using a hand-held dynamometer. Nine subjects (five males, four females), physically active for at least 2.5 h a week, were included. Twelve standardized isometric strength tests were performed twice with a 1-week interval in between......Hip strength assessment plays an important role in the clinical examination of the hip and groin region. The primary aim of this study was to examine the absolute test-retest measurement variation concerning standardized strength assessments of hip abduction (ABD), adduction (ADD), external...... by the same examiner. The test order was randomized to avoid systematic bias. Measurement variation between sessions was 3-12%. When the maximum value of four measurements was used, test-retest measurement variation was below 10% in 11 of the 12 individual hip strength tests and below 5% in five of the 12...

  1. Detection of sentinel lymph node in breast cancer and malignant melanoma - Influence of some factors on detection success rate

    International Nuclear Information System (INIS)

    Krafta, O.; Safarcika, K.; Stepien, A.

    2004-01-01

    Full text: The aim of this study was to compare three radiopharmaceuticals for sentinel lymph node detection in breast cancer and malignant melanoma patients. We examined 100 women and 2 men with breast cancer (average age 59.3 years) and 167 patients with malignant melanoma (69 men with mean age of 58.6 years and 98 women with mean age of 53.6 years). Lymphoscintigraphy was performed in all patients after injection of the radiotracer, either of the three: NANOCIS (average particle size 100 nm), SENTISCINT (particle size 100-600 nm), and NANOCOLL (particle size under 80 nm). Dynamic scintigraphy was performed in melanoma patients while breast cancer patients were subjected to stating imaging at 1-2 and 22 hours of injection. In patients with melanoma surgery was done on the same day, to remove the primary tumor, sentinel lymph node and other nodes, wherever required. In breast cancer patients, surgery, more or less, was done on the second day of radiotracer injection. In operation theatre isosulfan blue dye and gamma probe was used to detect sentinel lymph nodes. In breast cancer patients, scintigraphy detected a total of 231 lymph nodes but failed to show sentinel lymph node in 7 patients (success rate of lymphoscintigraphy 93.1 %). Using gamma probe 158 lymph nodes were detected in 89 patients but sentinel nodes were missed in 9 patients (success rate of probe was 89.9 %). 146 lymph nodes could be visualised using blue dye in 92 patients but were missed in 12 patients (detection rate by dye was 87 %). In 2 patients sentinel lymph node could not be detected by any method. In patients with melanoma, scintigraphy showed 304 lymph nodes. However, it did not detect sentinel lymph node in 9 patients (success rate of lymphoscintigraphy was 94.6 %). 104 patients were examined by means of gamma probe and 132 lymph nodes were detected and no lymph node was found in 13 patients (success rate of probe 87.5%). Using blue dye in 140 patients, 131 nodes were found but were

  2. Visual Tracking of Deformation and Classification of Non-Rigid Objects with Robot Hand Probing

    Directory of Open Access Journals (Sweden)

    Fei Hui

    2017-03-01

    Full Text Available Performing tasks with a robot hand often requires a complete knowledge of the manipulated object, including its properties (shape, rigidity, surface texture and its location in the environment, in order to ensure safe and efficient manipulation. While well-established procedures exist for the manipulation of rigid objects, as well as several approaches for the manipulation of linear or planar deformable objects such as ropes or fabric, research addressing the characterization of deformable objects occupying a volume remains relatively limited. The paper proposes an approach for tracking the deformation of non-rigid objects under robot hand manipulation using RGB-D data. The purpose is to automatically classify deformable objects as rigid, elastic, plastic, or elasto-plastic, based on the material they are made of, and to support recognition of the category of such objects through a robotic probing process in order to enhance manipulation capabilities. The proposed approach combines advantageously classical color and depth image processing techniques and proposes a novel combination of the fast level set method with a log-polar mapping of the visual data to robustly detect and track the contour of a deformable object in a RGB-D data stream. Dynamic time warping is employed to characterize the object properties independently from the varying length of the tracked contour as the object deforms. The proposed solution achieves a classification rate over all categories of material of up to 98.3%. When integrated in the control loop of a robot hand, it can contribute to ensure stable grasp, and safe manipulation capability that will preserve the physical integrity of the object.

  3. Children's (Pediatric) Nuclear Medicine

    Medline Plus

    Full Text Available ... are detected by a special camera or imaging device that produces pictures and provides molecular information. In ... camera. A probe is a small hand-held device resembling a microphone that can detect and measure ...

  4. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... are detected by a special camera or imaging device that produces pictures and provides molecular information. The ... camera. A probe is a small hand-held device resembling a microphone that can detect and measure ...

  5. Analytical applications of neutron capture gamma-rays

    International Nuclear Information System (INIS)

    Lindstrom, R.M.; Paul, R.L.; Anderson, D.L.; Paul, R.L.

    1997-01-01

    Field and industrial applications of neutron capture gamma-ray spectrometry with isotopic sources or neutron generators are economically important. Geochemical exploration in boreholes is done routinely with neutron probes. Coal and ores are assayed with analyzers adjacent to a conveyor belt in dozens of industrial facilities. The use of capture gamma rays for explosives detection has been described in the literature, both for scanning airline baggage and for characterizing obsolete munitions; a packaged system for the latter is available commercially. Generalizations are drawn from the history of the field, and predictions are made about the future usefulness of capture gamma rays. (author)

  6. Comparison of maximal voluntary isometric contraction and hand-held dynamometry in measuring muscle strength of patients with progressive lower motor neuron syndrome

    NARCIS (Netherlands)

    Visser, J.; Mans, E.; de Visser, M.; van den Berg-Vos, R. M.; Franssen, H.; de Jong, J. M. B. V.; van den Berg, L. H.; Wokke, J. H. J.; de Haan, R. J.

    2003-01-01

    Context. Maximal voluntary isometric contraction, a method quantitatively assessing muscle strength, has proven to be reliable, accurate and sensitive in amyotrophic lateral sclerosis. Hand-held dynamometry is less expensive and more quickly applicable than maximal voluntary isometric contraction.

  7. Improvement of equipment needed for the detection and characterization of nuclear material and radioactive samples at borders

    International Nuclear Information System (INIS)

    Arlt, R.; Kovar, A.; Swoboda, M.; Beck, P.; Duftschmid, K.E.; Lewis, W.

    2001-01-01

    Nuclear radiation measurement instruments and devices for the detection and characterisation of nuclear material and radioactive isotopes at borders play a decisive role in the set of technical measures needed to deal with the problem of illicit trafficking. Therefore the availability of a range of devices with adequate performance at affordable prices is essential. The needed equipment can be classified into the following categories: Detection equipment (border monitors and radiation pagers); Hand held devices for neutron/gamma source search and in-field characterisation of radiation sources by customs inspectors; NDA (non-destructive assay) instruments for in-depth investigation of a seized item by experts either in the field or under laboratory conditions. Instruments and techniques, which use destructive assay methods, are not considered in this paper. The most recent overview on the performance of such instruments is given in the Final Report of ITRAP (Illicit Trafficking Radiation Detection Assessment Program). According to the findings of ITRAP, although in all above mentioned categories equipment is commercially available, deficiencies and shortcomings were identified. In this paper we describe our effort in addressing some of the most essential equipment problems, identified in ITRAP - the sensitivity of border monitors with respect to the detection of nuclear material and the performance and usability of hand held and portable devices needed for in-field characterisation of seized items by customs inspectors

  8. Probing Pre-Galactic Metal Enrichment with High-Redshift Gamma-Ray Bursts

    Science.gov (United States)

    Wang, F. Y.; Bromm, Volker; Greif, Thomas H.; Stacy, Athena; Dai, Z. G.; Loeb, Abraham; Cheng, K. S.

    2012-01-01

    We explore high-redshift gamma-ray bursts (GRBs) as promising tools to probe pre-galactic metal enrichment. We utilize the bright afterglow of a Population III (Pop III) GRB exploding in a primordial dwarf galaxy as a luminous background source, and calculate the strength of metal absorption lines that are imprinted by the first heavy elements in the intergalactic medium (IGM). To derive the GRB absorption line diagnostics, we use an existing highly resolved simulation of the formation of a first galaxy which is characterized by the onset of atomic hydrogen cooling in a halo with virial temperature approximately greater than10(exp 4) K.We explore the unusual circumburst environment inside the systems that hosted Pop III stars, modeling the density evolution with the self-similar solution for a champagne flow. For minihalos close to the cooling threshold, the circumburst density is roughly proportional to (1 + z) with values of about a few cm(exp -3). In more massive halos, corresponding to the first galaxies, the density may be larger, n approximately greater than100 cm(exp -3). The resulting afterglow fluxes are weakly dependent on redshift at a fixed observed time, and may be detectable with the James Webb Space Telescope and Very Large Array in the near-IR and radio wavebands, respectively, out to redshift z approximately greater than 20. We predict that the maximum of the afterglow emission shifts from near-IR to millimeter bands with peak fluxes from mJy to Jy at different observed times. The metal absorption line signature is expected to be detectable in the near future. GRBs are ideal tools for probing the metal enrichment in the early IGM, due to their high luminosities and featureless power-law spectra. The metals in the first galaxies produced by the first supernova (SN) explosions are likely to reside in low-ionization stages (C II, O I, Si II and Fe II). We show that, if the afterglow can be observed sufficiently early, analysis of the metal lines may

  9. Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study

    Science.gov (United States)

    Perraton, Luke G.; Bower, Kelly J.; Adair, Brooke; Pua, Yong-Hao; Williams, Gavin P.; McGaw, Rebekah

    2015-01-01

    Introduction Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to examine the reliability of different algorithms for RFD calculation and to examine the intra-rater, inter-rater, and inter-device reliability of HHD as well as the concurrent validity of HHD for the assessment of isometric lower limb muscle strength and power. Methods 30 healthy young adults (age: 23±5yrs, male: 15) were assessed on two sessions. Isometric muscle strength and power were measured using peak force and RFD respectively using two HHDs (Lafayette Model-01165 and Hoggan microFET2) and a criterion-reference KinCom dynamometer. Statistical analysis of reliability and validity comprised intraclass correlation coefficients (ICC), Pearson correlations, concordance correlations, standard error of measurement, and minimal detectable change. Results Comparison of RFD methods revealed that a peak 200ms moving window algorithm provided optimal reliability results. Intra-rater, inter-rater, and inter-device reliability analysis of peak force and RFD revealed mostly good to excellent reliability (coefficients ≥ 0.70) for all muscle groups. Concurrent validity analysis showed moderate to excellent relationships between HHD and fixed dynamometry for the hip and knee (ICCs ≥ 0.70) for both peak force and RFD, with mostly poor to good results shown for the ankle muscles (ICCs = 0.31–0.79). Conclusions Hand-held dynamometry has good to excellent reliability and validity for most measures of isometric lower limb strength and power in a healthy population, particularly for proximal muscle groups. To aid implementation we have created freely available software to extract these variables from data stored on the Lafayette device. Future research should examine the reliability

  10. Blinded Comparison between an In-Air Reverberation Method and an Electronic Probe Tester in the Detection of Ultrasound Probe Faults.

    Science.gov (United States)

    Dudley, Nicholas J; Woolley, Darren J

    2017-12-01

    The aim of this study was to perform a blinded trial, comparing the results of a visual inspection of the in-air reverberation pattern with the results of an electronic probe tester in detecting ultrasound probe faults. Sixty-two probes were tested. A total of 28 faults were found, 3 only by in-air reverberation assessment and 2 only by the electronic probe tester. The electronic probe tester provided additional information regarding the location of the fault in 74% of the cases in which both methods detected a fault. It is possible to detect the majority of probe faults by visual inspection and in-air reverberation assessment. The latter provides an excellent first-line test, easily performed on a daily basis by equipment users. An electronic probe tester is required if detailed evaluation of faults is necessary. Copyright © 2017 World Federation for Ultrasound in Medicine and Biology. All rights reserved.

  11. Potential air contamination during CO2 angiography using a hand-held syringe: theoretical considerations and gas chromatography.

    Science.gov (United States)

    Cho, David R; Cho, Kyung J; Hawkins, Irvin F

    2006-01-01

    To assess air contamination in the hand-held syringes currently used for CO2 delivery and to determine whether there is an association between their position and the rate of air contamination. Assessment of air contamination in the syringe (20 ml) included theoretical modeling, mathematical calculation, and gas chromatography (GC). The model was used with Fick's first law to calculate the diffusion of CO2 and the amount of air contamination. For GC studies, the syringes were placed in the upright, horizontal, and inverted positions and gas samples were obtained after 5, 10, 20, 30, and 60 min. All trials with each position for each sampling time were performed five times. The amounts of air contamination with time calculated mathematically were 5-10% less than those of GC. With the diffusivity of air-CO2 at 0.1599 cm2/sec (9.594 cm2/min), air contamination was calculated to be 60% at 60 min. With GC air contamination was 13% at 5 min, 31% at 20 min, 43% at 30 min, and 68% at 60 min. There was no difference in air contamination between the different syringe positions. Air contamination occurs in hand-held syringes filled with CO2 when they are open to the ambient air. The amounts of air contamination over time are similar among syringes placed in the upright, horizontal, and inverted positions.

  12. Security enhancement of hand geometry scanners using optical blood flow detection

    Science.gov (United States)

    Crihalmeanu, Musat C.; Jerabek, Mark A.; Meehan, Kathleen

    2004-08-01

    In today's security conscious society the efficiency of biometric systems has an increasing tendency to replace the classic but less effective keys and passwords. Hand geometry readers are popular biometrics used for acces control and time and attendance applications. One of their weaknesses is vulnerability to spoofing using fake hands (latex, play-doh or dead-hands). The object of this paper is to design a feature to be added to the hand geometry scanner in order to detect vitality in the hand, reducing the possibilities for spoofing. This paper demonstrates how the hand reader was successfully spoofed and shows the implementation of the vitality detection feature through an inexpensive but efficient electronic design. The method used for detection is photo-plethysmography. The Reflectance Sensor built is of original conception. After amplifying, filtering and processing the sensor's signal, a message is shown via an LCD display, concerning the liveness of the hand and the pulse rate.

  13. Radiation anomaly detection algorithms for field-acquired gamma energy spectra

    Science.gov (United States)

    Mukhopadhyay, Sanjoy; Maurer, Richard; Wolff, Ron; Guss, Paul; Mitchell, Stephen

    2015-08-01

    The Remote Sensing Laboratory (RSL) is developing a tactical, networked radiation detection system that will be agile, reconfigurable, and capable of rapid threat assessment with high degree of fidelity and certainty. Our design is driven by the needs of users such as law enforcement personnel who must make decisions by evaluating threat signatures in urban settings. The most efficient tool available to identify the nature of the threat object is real-time gamma spectroscopic analysis, as it is fast and has a very low probability of producing false positive alarm conditions. Urban radiological searches are inherently challenged by the rapid and large spatial variation of background gamma radiation, the presence of benign radioactive materials in terms of the normally occurring radioactive materials (NORM), and shielded and/or masked threat sources. Multiple spectral anomaly detection algorithms have been developed by national laboratories and commercial vendors. For example, the Gamma Detector Response and Analysis Software (GADRAS) a one-dimensional deterministic radiation transport software capable of calculating gamma ray spectra using physics-based detector response functions was developed at Sandia National Laboratories. The nuisance-rejection spectral comparison ratio anomaly detection algorithm (or NSCRAD), developed at Pacific Northwest National Laboratory, uses spectral comparison ratios to detect deviation from benign medical and NORM radiation source and can work in spite of strong presence of NORM and or medical sources. RSL has developed its own wavelet-based gamma energy spectral anomaly detection algorithm called WAVRAD. Test results and relative merits of these different algorithms will be discussed and demonstrated.

  14. Detecting 3D Vegetation Structure with the Galileo Space Probe: Can a Distant Probe Detect Vegetation Structure on Earth?

    Science.gov (United States)

    Doughty, Christopher E; Wolf, Adam

    2016-01-01

    Sagan et al. (1993) used the Galileo space probe data and first principles to find evidence of life on Earth. Here we ask whether Sagan et al. (1993) could also have detected whether life on Earth had three-dimensional structure, based on the Galileo space probe data. We reanalyse the data from this probe to see if structured vegetation could have been detected in regions with abundant photosynthetic pigments through the anisotropy of reflected shortwave radiation. We compare changing brightness of the Amazon forest (a region where Sagan et al. (1993) noted a red edge in the reflectance spectrum, indicative of photosynthesis) as the planet rotates to a common model of reflectance anisotropy and found measured increase of surface reflectance of 0.019 ± 0.003 versus a 0.007 predicted from only anisotropic effects. We hypothesize the difference was due to minor cloud contamination. However, the Galileo dataset had only a small change in phase angle (sun-satellite position) which reduced the observed anisotropy signal and we demonstrate that theoretically if the probe had a variable phase angle between 0-20°, there would have been a much larger predicted change in surface reflectance of 0.1 and under such a scenario three-dimensional vegetation structure on Earth could possibly have been detected. These results suggest that anisotropic effects may be useful to help determine whether exoplanets have three-dimensional vegetation structure in the future, but that further comparisons between empirical and theoretical results are first necessary.

  15. Detecting 3D Vegetation Structure with the Galileo Space Probe: Can a Distant Probe Detect Vegetation Structure on Earth?

    Directory of Open Access Journals (Sweden)

    Christopher E Doughty

    Full Text Available Sagan et al. (1993 used the Galileo space probe data and first principles to find evidence of life on Earth. Here we ask whether Sagan et al. (1993 could also have detected whether life on Earth had three-dimensional structure, based on the Galileo space probe data. We reanalyse the data from this probe to see if structured vegetation could have been detected in regions with abundant photosynthetic pigments through the anisotropy of reflected shortwave radiation. We compare changing brightness of the Amazon forest (a region where Sagan et al. (1993 noted a red edge in the reflectance spectrum, indicative of photosynthesis as the planet rotates to a common model of reflectance anisotropy and found measured increase of surface reflectance of 0.019 ± 0.003 versus a 0.007 predicted from only anisotropic effects. We hypothesize the difference was due to minor cloud contamination. However, the Galileo dataset had only a small change in phase angle (sun-satellite position which reduced the observed anisotropy signal and we demonstrate that theoretically if the probe had a variable phase angle between 0-20°, there would have been a much larger predicted change in surface reflectance of 0.1 and under such a scenario three-dimensional vegetation structure on Earth could possibly have been detected. These results suggest that anisotropic effects may be useful to help determine whether exoplanets have three-dimensional vegetation structure in the future, but that further comparisons between empirical and theoretical results are first necessary.

  16. Three-dimensional modeling of physiological tremor for hand-held surgical robotic instruments.

    Science.gov (United States)

    Tatinati, Sivanagaraja; Yan Naing Aye; Pual, Anand; Wei Tech Ang; Veluvolu, Kalyana C

    2016-08-01

    Hand-held robotic instruments are developed to compensate physiological tremor in real-time while augmenting the required precision and dexterity into normal microsurgical work-flow. The hardware (sensors and actuators) and software (causal linear filters) employed for tremor identification and filtering introduces time-varying unknown phase-delay that adversely affects the device performance. The current techniques that focus on three-dimensions (3D) tip position control involves modeling and canceling the tremor in 3-axes (x, y, and z axes) separately. Our analysis with the tremor data recorded from surgeons and novice subjects show that there exists significant correlation in tremor motion across the dimensions. Motivated by this, a new multi-dimensional modeling approach based on extreme learning machines (ELM) is proposed in this paper to correct the phase delay and to accurately model tremulous motion in three dimensions simultaneously. A study is conducted with tremor data recorded from the microsurgeons to analyze the suitability of proposed approach.

  17. Traversing incore probe device

    International Nuclear Information System (INIS)

    Yoshioka, Michiko.

    1985-01-01

    Purpose: To measure the neutron flux distribution in the reactor core always at a high accuracy. Constitution: A nuclear fission ionizing chamber type detector is disposed at the end of a cable for sending a detection signal of a traversing incore probe device and, further, a gamma-ray ionizing chamber type detector is connected in adjacent therewith and a selection circuit for selecting both of the detection signals and inputting them to a display device is disposed. Then, compensation for the neutron monitors is conducted by the gamma-ray ionizing chamber type detector during normal operation in which control rods are not driven and the positioning is carried out by the nuclear fission ionizing chamber type detector. Furthermore, both of the compensation for the neutron detector and the positioning are carried out by the nuclear fission ionizing chamber type detector upon starting where the control rods are driven. (Sekiya, K.)

  18. Digital knowledge in the coat pocket - hand-held personal digital assistants in radiology

    International Nuclear Information System (INIS)

    Niehues, S.M.; Froehlich, M.; Felix, R.; Lemke, A.J.

    2004-01-01

    The personal digital assistant (PDA) enables the independent access to large data in a pocket-sized format. The applications for hand-held computers are growing steadily and can support almost any kind of problem. An overview of the available hardware and software is provided and evaluated. Furthermore, the use of the PDA in the clinical daily routine is described. In view of the numerous software programs available in radiology, the range of software solutions for radiologists is presented. Despite the high acquisition cost, the PDA has already become the digital assistant for the radiologist. After a short time of getting used to the PDA, nobody wants to miss it at work or at home. New technical features and available software programs will continuously increase the integration of the PDA into the medical workflow in the near future. (orig.)

  19. Utilisation of prompt fission neutron technology in Greenfields uranium exploration

    International Nuclear Information System (INIS)

    Mutz, P.R.

    2007-01-01

    Conventionally, gamma detection technology has been used in uranium exploration programs for the initial detection of uranium as well as for a determination of uranium concentration. Geophysical logging companies use wireline gamma probes to measure uranium within boreholes, and field technicians utilise hand held gamma meters to detect uranium in rock samples, drill cuttings and cores. Borehole geophysical logging equipment typically records the uranium concentration as %eU 3 O8, where e represents an equivalent determination of uranium concentration as opposed to a laboratory assay. This method of uranium determination is an indirect method, as it measures gamma radiation from uranium-238 (U-238) isotope decay chain progeny; principally the bismuth-214 (Bi-214) isotope. Consequently, the uranium determination can be inaccurate due to natural disequilibrium between the U-238 parent and the decay chain progeny. This is especially true in sedimentary hosted uranium deposits, where the uranium and daughter progeny may have been geochemically separated. The gamma detection method for uranium can also be rendered inaccurate by detecting the gamma signature from potassium in clays as well as from thorium; both of which can provide a false (enhanced) eU 3 O8 determination. Prompt Fission Neutron (PFN) technology is a geophysical wireline logging technology used in the same manner as conventional gamma logging. The difference is that PFN provides a direct determination of uranium within a borehole, irrespective of natural disequilibrium or the presence of other radioactive elements. This paper provides a brief description of natural uranium and radioactivity as a basis for explaining the conventional use of gamma radiation detectors for the detection and determination of uranium concentration in exploration boreholes, including the potential pitfalls of this technology. A detailed description of prompt fission neutron technology is also presented, along with a discussion

  20. Applications of outcrop gamma-ray logging to field development and exploration

    International Nuclear Information System (INIS)

    Jordan, D.W.; Slatt, R.M.; Gillespie, R.H.; D'Agostino, A.E.; Scheihing, M.H.

    1991-01-01

    Gamma-ray logs of outcrops have been generated using two techniques. These techniques demonstrate the applicability of outcrop logging to better understand reservoir facies architecture and exploration type problems. The first logging technique employs the use of a standard logging truck and gamma-ray sonde. The truck is positioned near the top of the cliff face and the sonde is lowered to the bottom of the cliff. Gamma-ray counts are recorded as the sonde is raised at a constant rate. The second logging technique employs the use of a commercially available, hand-held, gamma-ray scintillometer. The tool measures total radiation at the outcrop. Equally-spaced measurements are made along the section and are displayed as a function of depth below a reference point. In this paper examples of gamma-ray logging experiments conducted on turbidities of the Jackfork Group (Pennsylvanian) in central and southern Arkansas are discussed, as are application of outcrop gamma-ray logging in the Long Beach Unit of Wilmington Oil Field, California, and Point Mugu (Santa Barbara Channel), California

  1. Development of Neutron Probes for Characterization of Hazardous Materials in the Sub-surface Medium

    International Nuclear Information System (INIS)

    Keegan, R.P.; McGrath, C.A.; Lopez, J.C.

    2002-01-01

    Neutron probes are being developed at the Idaho National Engineering and Environmental Laboratory (INEEL) for the detection, identification and quantification of hazardous materials in the ground. Such materials include plutonium, uranium, americium, chlorine and fluorine. Both a Neutron Gamma (NG) probe and a Prompt Fission Neutron (PFN) probe are being developed. The NG probe is used primarily for nuclide identification and quantification measurements. The PFN is used mostly for the detection and measurement of fissile material, but also for the determination of thermal neutron macroscopic absorption cross sections of the various elements comprising the ground matrix. Calibration of these probes will be carried out at the INEEL using an indoor facility that has been designed for this activity

  2. Nuclear borehole probes - theory and experiments

    International Nuclear Information System (INIS)

    Joergensen, J.L.; Korsbech, U.; Gynther Nielsen, K.; Oelgaard, P.L.

    1985-06-01

    The report gives a summary of the theoretical and expeimental work on borehole probes that has been performed since 1971 at The Department of Electrophysics, The Technical University of Denmark. The first part of the report concerns the use of a spectral natural gamma-ray probe (SNG-probe), which is used for measurements of the spectral distribution of the gamma-rays of the geological strata around a borehole. In general the spectrum is divided into three parts - the gamma-rays from potassium-40, from thorium-232 and daughters, and from uranium-238 and daughters. A set of curves showing the intensities of the gamm-radiation from K, Th, and U versus depth is called a SNG-log. If proper calibrated, the SNG-log gives the concentration of Th, U, and K in the formation surrounding the borehole. Initially the basis for an interpretation of SNG-logs is discussed. Then follows a description og some SNG-problems designed and built by The Department of Electrophysics, and a discussion of the calibration of SNG-probes. Some examples of SNG-logs are presented, and some general comments on the use of SNG-logs are given. The second part of the report concerns mainly the development of theoretical models for neutron-neutron probes, gamma-gamma probes, and pulsed-neutron probes. The purpose of this work has been to examine how well the models correlate with measured results and - where reasonable agreement is found - to use the models in studies of the factors that affect the probe responses in interpretation of experimental results and in probe design. (author)

  3. Crack detection by mobile photothermal probe

    International Nuclear Information System (INIS)

    Besnard, R.; Le Blanc, A.; Sellier, J.Y.

    1993-01-01

    This paper deals with an industrial method for crack detection. The apparatus presented is based on a mobile photothermal probe. It can be used under different modes (sinusoidal, pulsed or scanned excitation). Moreover, the description of the device provided includes theoretical and experimental results. (TEC). 7 refs., 6 figs

  4. Sheath-lens probe for negative ion detection in reactive plasmas

    International Nuclear Information System (INIS)

    Stamate, E.; Sugai, H.; Takai, O.; Ohe, K.

    2004-01-01

    A method that allows easy and inexpensive detection of negative ions is introduced. The method is based upon the electrostatic lens effect of the sheath layer evolving to a positively biased planar probe that focuses the negative charges to distinct regions on the surface. Trajectories of negative ions inside the sheath are obtained after computing the potential and electric field distribution by solving in three dimensions the nonlinear Poisson equation. The negative ions' flux to square and disk probes is developed in Ar/SF 6 and O 2 plasmas. The method allows negative ion detection with sensitivity higher than that of Langmuir probes

  5. Detection of TTV-DNA in PBMC using digoxigenin labelled probe by in situ hybridization

    International Nuclear Information System (INIS)

    Liu Yang; Qi Qige

    2002-01-01

    To determine TTV-DNA in PBMC in patients with viral hepatitis, a study of in situ hybridization using digoxigenin labelled probe by PCR method to the TTV ORF1 region was performed on PBMC. Results showed that the detection rate of TTV-DNA using double-stranded probe in TTV-DNA positive group in sera was 58.06 (18/31), and the detection rate of TTV-DNA using double-stranded probe in TTV-DNA negative group in sera was 27.59 (8/29). For TTV-DNA positive group detected by double- stranded probe, then we use negative- stranded probe to detect their replication. The detection rate was 22.2%(4/18). Conclusions: TTV can infect PBMC and replicate in PBMC

  6. Communication: Probing the absolute configuration of chiral molecules at aqueous interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Lotze, Stephan, E-mail: lotze@amolf.nl; Versluis, Jan [FOM Institute for Atomic and Molecular Physics, Science Park 104, 1098 XG Amsterdam (Netherlands); Olijve, Luuk L. C.; Schijndel, Luuk van; Milroy, Lech G.; Voets, Ilja K. [Laboratory of Macromolecular and Organic Chemistry, Department of Chemical Engineering and Chemistry, and Institute for Complex Molecular Systems, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Bakker, Huib J., E-mail: bakker@amolf.nl [FOM Institute AMOLF, Science Park 104, 1098 XG Amsterdam (Netherlands)

    2015-11-28

    We demonstrate that the enantiomers of chiral macromolecules at an aqueous interface can be distinguished with monolayer sensitivity using heterodyne-detected vibrational sum-frequency generation (VSFG). We perform VSFG spectroscopy with a polarization combination that selectively probes chiral molecular structures. By using frequencies far detuned from electronic resonances, we probe the chiral macromolecular structures with high surface specificity. The phase of the sum-frequency light generated by the chiral molecules is determined using heterodyne detection. With this approach, we can distinguish right-handed and left-handed helical peptides at a water-air interface. We thus show that heterodyne-detected VSFG is sensitive to the absolute configuration of complex, interfacial macromolecules and has the potential to determine the absolute configuration of enantiomers at interfaces.

  7. Potential Air Contamination During CO2 Angiography Using a Hand-Held Syringe: Theoretical Considerations and Gas Chromatography

    International Nuclear Information System (INIS)

    Cho, David R.; Cho, Kyung J.; Hawkins, Irvin F.

    2006-01-01

    Purpose. To assess air contamination in the hand-held syringes currently used for CO 2 delivery and to determine whether there is an association between their position and the rate of air contamination. Methods. Assessment of air contamination in the syringe (20 ml) included theoretical modeling, mathematical calculation, and gas chromatography (GC). The model was used with Fick's first law to calculate the diffusion of CO 2 and the amount of air contamination. For GC studies, the syringes were placed in the upright, horizontal, and inverted positions and gas samples were obtained after 5, 10, 20, 30, and 60 min. All trials with each position for each sampling time were performed five times. Results. The amounts of air contamination with time calculated mathematically were 5-10% less than those of GC. With the diffusivity of air-CO 2 at 0.1599 cm 2 /sec (9.594 cm 2 /min), air contamination was calculated to be 60% at 60 min. With GC air contamination was 13% at 5 min, 31% at 20 min, 43% at 30 min, and 68% at 60 min. There was no difference in air contamination between the different syringe positions. Conclusion. Air contamination occurs in hand-held syringes filled with CO 2 when they are open to the ambient air. The amounts of air contamination over time are similar among syringes placed in the upright, horizontal, and inverted positions

  8. Real time monitoring automation of dose rate absorbed in air due to environmental gamma radiation

    International Nuclear Information System (INIS)

    Dominguez Ley, Orlando; Capote Ferrera, Eduardo; Carrazana Gonzalez, Jorge A.; Manzano de Armas, Jose F.; Alonso Abad, Dolores; Prendes Alonso, Miguel; Tomas Zerquera, Juan; Caveda Ramos, Celia A.; Kalber, Olof; Fabelo Bonet, Orlando; Montalvan Estrada, Adelmo; Cartas Aguila, Hector; Leyva Fernandez, Julio C.

    2005-01-01

    The Center of Radiation Protection and Hygiene (CPHR) as the head institution of the National Radiological Environmental Surveillance Network (RNVRA) has strengthened its detection and response capacity for a radiological emergency situation. The measurements of gamma dose rate at the main point of the RNVRA are obtained in real time and the CPHR receives the data coming from those points in a short time. To achieve the operability of the RNVRA it was necessary to complete the existent monitoring facilities using 4 automatic gamma probes, implementing in this way a real time measurement system. The software, GenitronProbe for obtaining the data automatically from the probe, Data Mail , for sending the data via e-mail, and Gamma Red , for receiving and processing the data in the head institution ,were developed

  9. DETECTION OF GAMMA-RAY EMISSION FROM THE ETA-CARINAE REGION

    International Nuclear Information System (INIS)

    Tavani, M.; Viotti, R. F.; Argan, A.; Cocco, V.; D'Ammando, F.; Costa, E.; Sabatini, S.; Pian, E.; Bulgarelli, A.; Caraveo, P.; Giuliani, A.; Vercellone, S.; Mereghetti, S.; Chen, A. W.; Corcoran, M. F.; Pittori, C.; Verrecchia, F.; Barbiellini, G.; Boffelli, F.; Cattaneo, P. W.

    2009-01-01

    We present the results of extensive observations by the gamma-ray AGILE satellite of the Galactic region hosting the Carina nebula and the remarkable colliding wind binary Eta Carinae (η Car) during the period 2007 July-2009 January. We detect a gamma-ray source (1AGL J1043-5931) consistent with the position of η Car. If 1AGL J1043-5931 is associated with the Car system, our data provide the long sought first detection above 100 MeV of a colliding wind binary. The average gamma-ray flux above 100 MeV and integrated over the preperiastron period 2007 July-2008 October is F γ = (37 ± 5) x 10 -8 ph cm -2 s -1 corresponding to an average gamma-ray luminosity of L γ = 3.4 x 10 34 erg s -1 for a distance of 2.3 kpc. We also report a two-day gamma-ray flaring episode of 1AGL J1043-5931 on 2008 October 11-13 possibly related to a transient acceleration and radiation episode of the strongly variable shock in the system.

  10. Atomic-scale investigations of grain boundary segregation in astrology with a three dimensional atom-probe

    Energy Technology Data Exchange (ETDEWEB)

    Blavette, D. [Rouen Univ., 76 - Mont-Saint-Aignan (France). Lab. de Microscopie Electronique]|[Institut Universitaire de France (France); Letellier, L. [Rouen Univ., 76 - Mont-Saint-Aignan (France). Lab. de Microscopie Electronique; Duval, P. [Rouen Univ., 76 - Mont-Saint-Aignan (France). Lab. de Microscopie Electronique; Guttmann, M. [Rouen Univ., 76 - Mont-Saint-Aignan (France). Lab. de Microscopie Electronique]|[Institut de Recherches de la Siderurgie Francaise (IRSID), 57 - Maizieres-les-Metz (France)

    1996-08-01

    Both conventional and 3D atom-probes were applied to the investigation of grain-boundary (GB) segregation phenomena in two-phase nickel base superalloys Astroloy. 3D images as provided by the tomographic atom-probe reveal the presence of a strong segregation of both boron and molybdenum at grain-boundaries. Slight carbon enrichment is also detected. Considerable chromium segregation is exhibited at {gamma}`-{gamma}` grain-boundaries. All these segregants are distributed in a continuous manner along the boundary over a width close to 0.5 nm. Experiments show that segregation occurs during cooling and more probably between 1000 C and 800 C. Boron and molybdenum GB enrichments are interpreted as due to an equilibrium type-segregation while chromium segregation is thought to be induced by {gamma}` precipitation at GB`s and stabilised by the presence of boron. No segregation of zirconium is detected. (orig.)

  11. Detection of GRB 060927 at z = 5.47: Implications for the Use of Gamma-Ray Bursts as Probes of the End of the Dark Ages

    NARCIS (Netherlands)

    Ruiz-Velasco, A.E.; Swan, H.; Troja, E.; Malesani, D.; Fynbo, J.P.U.; Starling, R.L.C.; Xu, D.; Aharonian, F.; Akerlof, C.; Andersen, M.I.; Ashley, M.C.B.; Barthelmy, S.D.; Bersier, D.F.; Cerón, J.M.; Castro-Tirado, A.J.; Gehrels, N.; Gögüs, E.; Gorosabel, J.; Guidorzi, C.; Güver, T.; Hjorth, J.; Horns, D.; Huang, K.Y.; Jakobsson, P.; Jensen, B.L.; Kiziloglu, Ü.; Kouveliotou, C.; Krimm, H.A.; Ledoux, C.; Levan, A.J.; Marsh, T.; McKay, T.; Melandri, A.; Milvang-Jensen, B.; Mundell, C.G.; O'Brien, P.T.; Özel, M.; Phillips, A.; Quimby, R.; Rowell, G.; Rujopakarn, W.; Rykoff, E.S.; Schaefer, B.E.; Sollerman, J.; Tanvir, N.R.; Thöne, C.C.; Urata, Y.; Vestrand, W.T.; Vreeswijk, P.M.; Watson, D.; Wheeler, J.C.; Wijers, R.A.M.J.; Wren, J.; Yost, S.A.; Yuan, F.; Zhai, M.; Zheng, W.K.

    2007-01-01

    We report on follow-up observations of the gamma-ray burst GRB 060927 using the robotic ROTSE-IIIa telescope and a suite of larger aperture ground-based telescopes. An optical afterglow was detected 20 s after the burst, the earliest rest-frame detection of optical emission from any GRB.

  12. Improving gross count gamma-ray logging in uranium mining with the NGRS probe

    Directory of Open Access Journals (Sweden)

    Carasco C.

    2018-01-01

    Full Text Available AREVA Mines and the Nuclear Measurement Laboratory of CEA Cadarache are collaborating to improve the sensitivity and precision of uranium concentration measurement by means of gamma ray logging. The determination of uranium concentration in boreholes is performed with the Natural Gamma Ray Sonde (NGRS based on a NaI(Tl scintillation detector. The total gamma count rate is converted into uranium concentration using a calibration coefficient measured in concrete blocks with known uranium concentration in the AREVA Mines calibration facility located in Bessines, France. Until now, to take into account gamma attenuation in a variety of boreholes diameters, tubing materials, diameters and thicknesses, filling fluid densities and compositions, a semi-empirical formula was used to correct the calibration coefficient measured in Bessines facility. In this work, we propose to use Monte Carlo simulations to improve gamma attenuation corrections. To this purpose, the NGRS probe and the calibration measurements in the standard concrete blocks have been modeled with MCNP computer code. The calibration coefficient determined by simulation, 5.3 s-1.ppmU-1 ± 10%, is in good agreement with the one measured in Bessines, 5.2 s-1.ppmU-1. Based on the validated MCNP model, several parametric studies have been performed. For instance, the rock density and chemical composition proved to have a limited impact on the calibration coefficient. However, gamma self-absorption in uranium leads to a nonlinear relationship between count rate and uranium concentration beyond approximately 1% of uranium weight fraction, the underestimation of the uranium content reaching more than a factor 2.5 for a 50 % uranium weight fraction. Next steps will concern parametric studies with different tubing materials, diameters and thicknesses, as well as different borehole filling fluids representative of real measurement conditions.

  13. Improving gross count gamma-ray logging in uranium mining with the NGRS probe

    Science.gov (United States)

    Carasco, C.; Pérot, B.; Ma, J.-L.; Toubon, H.; Dubille-Auchère, A.

    2018-01-01

    AREVA Mines and the Nuclear Measurement Laboratory of CEA Cadarache are collaborating to improve the sensitivity and precision of uranium concentration measurement by means of gamma ray logging. The determination of uranium concentration in boreholes is performed with the Natural Gamma Ray Sonde (NGRS) based on a NaI(Tl) scintillation detector. The total gamma count rate is converted into uranium concentration using a calibration coefficient measured in concrete blocks with known uranium concentration in the AREVA Mines calibration facility located in Bessines, France. Until now, to take into account gamma attenuation in a variety of boreholes diameters, tubing materials, diameters and thicknesses, filling fluid densities and compositions, a semi-empirical formula was used to correct the calibration coefficient measured in Bessines facility. In this work, we propose to use Monte Carlo simulations to improve gamma attenuation corrections. To this purpose, the NGRS probe and the calibration measurements in the standard concrete blocks have been modeled with MCNP computer code. The calibration coefficient determined by simulation, 5.3 s-1.ppmU-1 ± 10%, is in good agreement with the one measured in Bessines, 5.2 s-1.ppmU-1. Based on the validated MCNP model, several parametric studies have been performed. For instance, the rock density and chemical composition proved to have a limited impact on the calibration coefficient. However, gamma self-absorption in uranium leads to a nonlinear relationship between count rate and uranium concentration beyond approximately 1% of uranium weight fraction, the underestimation of the uranium content reaching more than a factor 2.5 for a 50 % uranium weight fraction. Next steps will concern parametric studies with different tubing materials, diameters and thicknesses, as well as different borehole filling fluids representative of real measurement conditions.

  14. Observation of galactic gamma radiation

    International Nuclear Information System (INIS)

    Paul, J.A.

    1982-09-01

    A complete and deep survey of the galactic high-energy gamma radiation is now available, thanks to the gamma-ray telescopes on board of the SAS-2 and COS-B spacecrafts. A comparison of the COS-B gamma-ray survey with a fully sampled CO survey together with an Hsub(I) survey is used to show that a simple model, in which uniformly distributed cosmic rays interact with the interstellar gas, can account for almost all the gamma-ray emission observed in the first galactic quadrant. At medium galactic latitudes, it is shown that a relationship exists between the gamma radiation and the interstellar absorption derived from galaxy counts. Therefore gamma rays from the local galactic environment can be used as a valuable probe of the content and structure of the local interstellar medium. The large scale features of the local interstellar gas are revealed, in particular wide concentrations of nearby molecular hydrogen. On a smaller scale, the detection of numerous localized gamma-ray sources focuses the attention on some particular phases of clusters of young and massive stars where diffuse processes of gamma-ray emission may also be at work

  15. Characterization of wood dust emission from hand-held woodworking machines.

    Science.gov (United States)

    Keller, F-X; Chata, F

    2018-01-01

    This article focuses on the prevention of exposure to wood dust when operating electrical hand-held sawing and sanding machines. A laboratory methodology was developed to measure the dust concentration around machines during operating processes. The main objective was to characterize circular saws and sanders, with the aim of classifying the different power tools tested in terms of dust emission (high dust emitter vs. low dust emitter). A test set-up was developed and is described and a measurement methodology was determined for each of the two operations studied. The robustness of the experimental results is discussed and shows good tendencies. The impact of air-flow extraction rate was assessed and the pressure loss of the system for each machine established. For the circular saws, three machines over the nine tested could be classified in the low dust emitter group. Their mean concentration values measured are between 0.64 and 0.98 mg/m 3 for the low dust emitter group and from 2.55 and 4.37 mg/m 3 for the high dust emitter group. From concentration measurements, a machine classification is possible-one for sanding machines and one for sawing machines-and a ratio from 1-7 is obtained when comparing the results. This classification will be helpful when a choice of high performance power tools, in terms of dust emission, must be made by professionals.

  16. Calibration, field-testing, and error analysis of a gamma-ray probe for in situ measurement of dry bulk density

    International Nuclear Information System (INIS)

    Bertuzzi, P.; Bruckler, L.; Gabilly, Y.; Gaudu, J.C.

    1987-01-01

    This paper describes a new gamma-ray probe for measuring dry bulk density in the field. This equipment can be used with three different tube spacings (15, 20 and 30 cm). Calibration procedures and local error analyses are proposed for two cases: (1) for the case where the access tubes are parallel, calibration equations are given for three tube spacings. The linear correlation coefficient obtained in the laboratory is satisfactory (0.999), and a local error analysis shows that the standard deviation in the measured dry bulk density is small (+/- 0.02 g/cm 3 ); (2) when the access tubes are not parallel, a new calibration procedure is presented that accounts for and corrects measurement bias due to the deviating probe spacing. The standard deviation associated with the measured dry bulk density is greater (+/- 0.05 g/cm 3 ), but the measurements themselves are regarded as unbiased. After comparisons of core samplings and gamma-ray probe measurements, a field validation of the gamma-ray measurements is presented. Field validation was carried out on a variety of soils (clay, clay loam, loam, and silty clay loam), using gravimetric water contents that varied from 0.11 0.27 and dry bulk densities ranging from 1.30-1.80 g°cm -3 . Finally, an example of dry bulk density field variability is shown, and the spatial variability is analyzed in regard to the measurement errors

  17. 2-Aminopurine hairpin probes for the detection of ultraviolet-induced DNA damage

    International Nuclear Information System (INIS)

    El-Yazbi, Amira F.; Loppnow, Glen R.

    2012-01-01

    Highlights: ► Molecular beacon with 2AP bases detects DNA damage in a simple mix-and-read assay. ► Molecular beacons with 2AP bases detect damage at a 17.2 nM limit of detection. ► The 2AP molecular beacon is linear over a 0–3.5 μM concentration range for damage. - Abstract: Nucleic acid exposure to radiation and chemical insults leads to damage and disease. Thus, detection and understanding DNA damage is important for elucidating molecular mechanisms of disease. However, current methods of DNA damage detection are either time-consuming, destroy the sample, or are too specific to be used for generic detection of damage. In this paper, we develop a fluorescence sensor of 2-aminopurine (2AP), a fluorescent analogue of adenine, incorporated in the loop of a hairpin probe for the quantification of ultraviolet (UV) C-induced nucleic acid damage. Our results show that the selectivity of the 2AP hairpin probe to UV-induced nucleic acid damage is comparable to molecular beacon (MB) probes of DNA damage. The calibration curve for the 2AP hairpin probe shows good linearity (R 2 = 0.98) with a limit of detection of 17.2 nM. This probe is a simple, fast and economic fluorescence sensor for the quantification of UV-induced damage in DNA.

  18. Effect of hand sanitizer on the performance of fingermark detection techniques.

    Science.gov (United States)

    Chadwick, Scott; Neskoski, Melissa; Spindler, Xanthe; Lennard, Chris; Roux, Claude

    2017-04-01

    Hand sanitizers have seen a rapid increase in popularity amongst the general population and this increased use has led to the belief that hand sanitizers may have an effect on subsequent fingermark detection. Based on this hypothesis, three alcoholic and two non-alcoholic hand sanitizers were evaluated to determine the effect they had on the detection of fingermarks deposited after their use. The following fingermark detection methods were applied: 1,2-indanedione-zinc, ninhydrin, physical developer (porous substrate); and cyanoacrylate, rhodamine 6G, magnetic powder (non-porous substrate). Comparison between hand sanitized fingermarks and non-hand sanitized fingermarks showed that the alcohol-based hand sanitizers did not result in any visible differences in fingermark quality. The non-alcoholic hand sanitizers, however, improved the quality of fingermarks developed with 1,2-indanedione-zinc and ninhydrin, and marginally improved those developed with magnetic powder. Different parameters, including time since hand sanitizer application prior to fingermark deposition and age of deposited mark, were tested to determine the longevity of increased development quality. The non-alcoholic hand sanitized marks showed no decrease in quality when aged for up to two weeks. The time since sanitizer application was determined to be an important factor that affected the quality of non-alcoholic hand sanitized fingermarks. It was hypothesized that the active ingredient in non-alcoholic hand sanitizers, benzalkonium chloride, is responsible for the increase in fingermark development quality observed with amino acid reagents, while the increased moisture content present on the ridges resulted in better powdered fingermarks. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. A simple and sensitive fluorescent probe for specific detection of ...

    Indian Academy of Sciences (India)

    Yan-Fei Kang

    A fluorescent probe, with simplicity of structure and convenience of synthesis, is capable of detecting ... Yan-Fei Kang et al. .... Pastore A, Federici G, Bertini E and Ptemonte F 2003 ... Urano Y 2010 New Strategies for Fluorescent Probe.

  20. Bismuth- and lithium-loaded plastic scintillators for gamma and neutron detection

    International Nuclear Information System (INIS)

    Cherepy, Nerine J.; Sanner, Robert D.; Beck, Patrick R.; Swanberg, Erik L.; Tillotson, Thomas M.; Payne, Stephen A.; Hurlbut, Charles R.

    2015-01-01

    Transparent plastic scintillators based on polyvinyltoluene (PVT) have been fabricated with high loading of bismuth carboxylates for gamma spectroscopy, and with lithium carboxylates for neutron detection. When activated with a combination of standard fluors, 2,5-diphenyloxazole (PPO) and tetraphenylbutadiene (TPB), gamma light yields with 15 wt% bismuth tripivalate of 5000 Ph/MeV are measured. A PVT plastic formulation including 30 wt% lithium pivalate and 30 wt% PPO offers both pulse shape discrimination, and a neutron capture peak at ~400 keVee. In another configuration, a bismuth-loaded PVT plastic is coated with ZnS( 6 Li) paint, permitting simultaneous gamma and neutron detection via pulse shape discrimination with a figure-of-merit of 3.8, while offering gamma spectroscopy with energy resolution of R(662 keV)=15%

  1. Detection Techniques of Microsecond Gamma-Ray Bursts Using Ground-based Telescopes

    International Nuclear Information System (INIS)

    Krennrich, F.; Le Bohec, S.; Weekes, T. C.

    2000-01-01

    Gamma-ray observations above 200 MeV are conventionally made by satellite-based detectors. The EGRET detector on the Compton Gamma Ray Observatory has provided good sensitivity for the detection of bursts lasting for more than 200 ms. Theoretical predictions of high-energy gamma-ray bursts produced by quantum mechanical decay of primordial black holes (Hawking) suggest the emission of bursts on shorter timescales. The final stage of a primordial black hole results in a burst of gamma rays, peaking around 250 MeV and lasting for 1/10 of a microsecond or longer depending on particle physics. In this work we show that there is an observational window using ground-based imaging Cerenkov detectors to measure gamma-ray burst emission at energies E>200 MeV. This technique, with a sensitivity for bursts lasting nanoseconds to several microseconds, is based on the detection of multiphoton-initiated air showers. (c) (c) 2000. The American Astronomical Society

  2. Contraband detection using high-energy gamma rays from 16O*

    International Nuclear Information System (INIS)

    Micklich, B.J.; Fink, C.L.; Sagalovsky, L.; Smith, D.L.

    1996-01-01

    High-energy monoenergetic gamma rays (6.13 and 7.12 MeV) from the decay of excited states of the 16 O* nucleus are highly penetrating and thus offer potential for non-intrusive inspection of loaded containers for narcotics, explosives, and other contraband items. These excited states can be produced by irradiation of water with 14-MeV neutrons from a DT neutron generator or through the 19 F(p,α) 16 O* reaction. Resonances in 19 F(p,α) 16 O* at proton energies between 340 keV and 2 MeV allow use of a low-energy accelerator to provide a compact, portable gamma source of reasonable intensity. The present work provides estimates of gamma source parameters and suggests how various types of contraband could be detected. Gamma rays can be used to perform transmission or emission radiography of containers or other objects. Through the use of (γ, n) and (γ, fission) reactions, this technique is also capable of detecting special nuclear materials such as deuterium, lithium, beryllium, uranium, and plutonium. Analytic and Monte Carlo techniques are used to model empty and loaded container inspection for accelerator-produced gamma, radioisotope, and x-ray sources

  3. VERITAS OBSERVATIONS OF GAMMA-RAY BURSTS DETECTED BY SWIFT

    International Nuclear Information System (INIS)

    Acciari, V. A.; Benbow, W.; Aliu, E.; Errando, M.; Arlen, T.; Aune, T.; Beilicke, M.; Buckley, J. H.; Bugaev, V.; Bradbury, S. M.; Byrum, K.; Cannon, A.; Collins-Hughes, E.; Cesarini, A.; Connolly, M. P.; Christiansen, J. L.; Ciupik, L.; Cui, W.; Duke, C.; Falcone, A.

    2011-01-01

    We present the results of 16 Swift-triggered Gamma-ray burst (GRB) follow-up observations taken with the Very Energetic Radiation Imaging Telescope Array System (VERITAS) telescope array from 2007 January to 2009 June. The median energy threshold and response time of these observations were 260 GeV and 320 s, respectively. Observations had an average duration of 90 minutes. Each burst is analyzed independently in two modes: over the whole duration of the observations and again over a shorter timescale determined by the maximum VERITAS sensitivity to a burst with a t –1.5 time profile. This temporal model is characteristic of GRB afterglows with high-energy, long-lived emission that have been detected by the Large Area Telescope on board the Fermi satellite. No significant very high energy (VHE) gamma-ray emission was detected and upper limits above the VERITAS threshold energy are calculated. The VERITAS upper limits are corrected for gamma-ray extinction by the extragalactic background light and interpreted in the context of the keV emission detected by Swift. For some bursts the VHE emission must have less power than the keV emission, placing constraints on inverse Compton models of VHE emission.

  4. Optimization of crack detection in steam generator tubes using a punctual probe

    International Nuclear Information System (INIS)

    Levy, R.; Ferre, C.

    1985-01-01

    The existence of cracks at the upper end of the expanded zone of a steam generator tube is a recent problem. A differential pencil probe was used for the detection of those cracks with encouraging results. An optimization study has been necessary to solve the difficulties in the evaluation of defects, due to the design of the first probe; the result is a probe making possible a precise analysis of detected signals

  5. Eddy current probe and method for flaw detection in metals

    Science.gov (United States)

    Watjen, John P.

    1987-06-23

    A flaw detecting system is shown which includes a probe having a pair of ferrite cores with in-line gaps in close proximity to each other. An insulating, non-magnetic, non-conducting holder fills the gaps and supports the ferrite cores in a manner such that the cores form a generally V-shape. Each core is provided with an excitation winding and a detection winding. The excitation windings are connected in series or parallel with an rf port for connection thereof to a radio frequency source. The detection windings, which are differentially wound, are connected in series circuit to a detector port for connection to a voltage measuring instrument. The ferrite cores at the in-line gaps directly engage the metal surface of a test piece, and the probe is scanned along the test piece. In the presence of a flaw in the metal surface the detection winding voltages are unbalanced, and the unbalance is detected by the voltage measuring instrument. The insulating holder is provided with a profile which conforms to that of a prominent feature of the test piece to facilitate movement of the probe along the feature, typically an edge or a corner.

  6. Hand-held dynamic visual noise reduces naturally occurring food cravings and craving-related consumption.

    Science.gov (United States)

    Kemps, Eva; Tiggemann, Marika

    2013-09-01

    This study demonstrated the applicability of the well-established laboratory task, dynamic visual noise, as a technique for reducing naturally occurring food cravings and subsequent food intake. Dynamic visual noise was delivered on a hand-held computer device. Its effects were assessed within the context of a diary study. Over a 4-week period, 48 undergraduate women recorded their food cravings and consumption. Following a 2-week baseline, half the participants watched the dynamic visual noise display whenever they experienced a food craving. Compared to a control group, these participants reported less intense cravings. They were also less likely to eat following a craving and consequently consumed fewer total calories following craving. These findings hold promise for curbing unwanted food cravings and craving-driven consumption in real-world settings. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. A hand-held 3D laser scanning with global positioning system of subvoxel precision

    International Nuclear Information System (INIS)

    Arias, Nestor; Meneses, Nestor; Meneses, Jaime; Gharbi, Tijani

    2011-01-01

    In this paper we propose a hand-held 3D laser scanner composed of an optical head device to extract 3D local surface information and a stereo vision system with subvoxel precision to measure the position and orientation of the 3D optical head. The optical head is manually scanned over the surface object by the operator. The orientation and position of the 3D optical head is determined by a phase-sensitive method using a 2D regular intensity pattern. This phase reference pattern is rigidly fixed to the optical head and allows their 3D location with subvoxel precision in the observation field of the stereo vision system. The 3D resolution achieved by the stereo vision system is about 33 microns at 1.8 m with an observation field of 60cm x 60cm.

  8. Feasibility Study on Fiber-optic Radiation Sensor for Remote Gamma-ray Spectroscopy

    International Nuclear Information System (INIS)

    Jeon, Hyesu; Jang, Kyoung Won; Shin, Sang Hun and others

    2014-01-01

    In this study, we fabricated a fiber-optic radiation sensor using an optical fiber and various scintillators. To select an adequate inorganic scintillator for the sensing probe of fiber-optic radiation sensor, 5 types of scintillators were evaluated. The spectra of gamma-rays emitted from a Na-22 radiation source were measured by using the manufactured sensors. As a result, the BGO was suitable for the sensing probe of fiber-optic radiation sensor due to its high scintillation output and exact photoelectric peak for the gamma-ray energy. The basic principle of radiation detection is to detect the signals caused by interactions between radiations and materials. There are various types of radiation detectors depending on types of radiation to be detected and physical quantities to be measured. As one of the radiation detectors, a fiber-optic radiation sensor using a scintillator and an optical fiber has two advantages such as no space restraint and remote sensing. Moreover, in nuclear environments, this kind of sensor has immunities for electromagnetic field, temperature, and pressure. Thus, the fiber-optic radiation sensor can be used in various fields including nondestructive inspection, radioactive waste management, nuclear safety, radiodiagnosis and radiation therapy. As a fundamental study of the fiber-optic radiation sensor for remote gamma-ray spectroscopy, in this study, we fabricated a fiber-optic radiation sensor using an optical fiber and various scintillators. To select an adequate inorganic scintillator for the sensing probe of fiber-optic radiation sensor, 5 types of scintillators were evaluated. The spectra of gamma-rays emitted from a Na-22 radiation source were measured by using the manufactured sensors

  9. Hand-held optical sensor using denatured antibody coated electro-active polymer for ultra-trace detection of copper in blood serum and environmental samples.

    Science.gov (United States)

    Chandra, Sutapa; Dhawangale, Arvind; Mukherji, Soumyo

    2018-07-01

    An optimum copper concentration in environment is highly desired for all forms of life. We have developed an ultrasensitive copper sensor which functions from femto to micro molar concentration accurately (R 2 = 0.98). The sensor is based on denatured antibody immunoglobulin G (IgG), immobilized on polyaniline (PAni) which in turn is the coating on the core of an optical fiber. The sensing relies on changes in evanescent wave absorbance in the presence of the analyte. The sensor showed excellent selectivity towards Cu (II) ions over all other metal ions. The sensor was tested with lake and marine water samples to determine unknown concentrations of copper ions and the recovery results were within 90-115%, indicating reasonable accuracy. We further integrated the fiber-optic sensor with a miniaturized hand-held instrumentation platform to develop an accurate and field deployable device which can broadly be applicable to determine Cu (II) concentration in a wide range of systems - natural water bodies, soil as well as blood serum. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Ballerina - pirouettes in search of gamma bursts

    DEFF Research Database (Denmark)

    Brandt, Søren Kristian; Lund, Niels; Pedersen, Henrik

    1999-01-01

    The cosmological origin of gamma ray bursts has now been established with reasonable certainty, Many more bursts will need to be studied to establish the typical distance scale, and to map out the large diversity in properties which have been indicated by the first handful of events. We are propo...... are proposing Ballerina, a small satellite to provide accurate positions and new data on the gamma-ray bursts. We anticipate a detection rate an order of magnitude larger than obtained from Beppo-SAX....

  11. ESA's Integral detects closest cosmic gamma-ray burst

    Science.gov (United States)

    2004-08-01

    5 August 2004 A gamma-ray burst detected by ESA's Integral gamma-ray observatory on 3 December 2003 has been thoroughly studied for months by an armada of space and ground-based observatories. Astronomers have now concluded that this event, called GRB 031203, is the closest cosmic gamma-ray burst on record, but also the faintest. This also suggests that an entire population of sub-energetic gamma-ray bursts has so far gone unnoticed... Gamma ray burst model hi-res Size hi-res: 22 KB Credits: CXC/M. Weiss Artist impression of a low-energy gamma-ray burst This illustration describes a model for a gamma-ray burst, like the one detected by Integral on 3 December 2003 (GRB 031203). A jet of high-energy particles from a rapidly rotating black hole interacts with surrounding matter. Observations with Integral on 3 December 2003 and data on its afterglow, collected afterwards with XMM-Newton, Chandra and the Very Large Array telescope, show that GRB 031203 radiated only a fraction of the energy of normal gamma-ray bursts. Like supernovae, gamma-ray bursts are thought to be produced by the collapse of the core of a massive star. However, while the process leading to supernovae is relatively well understood, astronomers still do not know what happens when a core collapses to form a black hole. The discovery of 'under-energetic' gamma-ray bursts, like GRB 031203, should provide valuable clues as to links between supernovae, black holes and gamma-ray bursts. Lo-res JPG (22 Kb) Hi-res TIFF (5800 Kb) Cosmic gamma-ray bursts (GRBs) are flashes of gamma rays that can last from less than a second to a few minutes and occur at random positions in the sky. A large fraction of them is thought to result when a black hole is created from a dying star in a distant galaxy. Astronomers believe that a hot disc surrounding the black hole, made of gas and matter falling onto it, somehow emits an energetic beam parallel to the axis of rotation. According to the simplest picture, all GRBs

  12. Design and expression of a short peptide as an HIV detection probe

    Energy Technology Data Exchange (ETDEWEB)

    Lines, Jamie A.; Yu, Zhiqiang; Dedkova, Larisa M.; Chen, Shengxi, E-mail: shengxi.chen.1@asu.edu

    2014-01-03

    Highlights: •We designed a short fusion peptide (FP-50) for in vivo expression. •This peptide is a very promising component for detection of gp120 protein. •The detectable level is about 20–200 times lower than previously published methods. •It is a novel probe to detect HIV-1 gp120 during early stages of HIV infection. -- Abstract: To explore a low-cost novel probe for HIV detection, we designed and prepared a 50-amino acid-length short fusion peptide (FP-50) via Escherichia coli in vivo expression. It was employed as a novel probe to detect HIV-1 gp120 protein. The detectable level of gp120 protein using the FP-50 peptide was approximately 20–200 times lower than previously published methods that used a pair of monoclonal antibodies. Thus, this short peptide is a very promising component for detection of gp120 protein during early stages of HIV infection.

  13. Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices.

    Science.gov (United States)

    Mair, B; Drillich, M; Klein-Jöbstl, D; Kanz, P; Borchardt, S; Meyer, L; Schwendenwein, I; Iwersen, M

    2016-02-24

    Dairy cows have a massive demand for glucose at the onset of lactation. A poor adaption to this period leads to an excessive negative energy balance with an increased risk for ketosis and impaired animal health and production. Besides the measurement of ketones, analysing the glucose concentration in blood is reported as helpful instrument for diagnosis and differentiation of ketosis. Monitoring metabolic parameters requires multiple blood sampling. In other species, new blood sampling techniques have been introduced in which small amounts of blood are rapidly analysed using electronic hand-held devices. The objective of this study was to evaluate the suitability of capillary blood for blood glucose measurement in dairy cows using the hand-held devices FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini) and the WellionVet GLUCO CALEA, (WGC, MED TRUST). In total, 240 capillary blood samples were obtained from dry and fresh lactating Holstein-Friesian cows. Blood was collected from the skin of the exterior vulva by using a lancet. For method comparison, additional blood samples were taken from a coccygeal vessel and analyzed in a laboratory. Glucose concentrations measured by a standard laboratory method were defined as the criterion standard. The Pearson correlation coefficients between the glucose concentrations analyzed in capillary blood with the devices and the reference were 73% for the FSP, 81% for the GLX and 41% for the WGC. Bland-Altman plots showed biases of -18.8 mg/dL for the FSP, -11.2 mg/dL for the GLX and +20.82 mg/dL for the WGC. The optimized threshold determined by a Receiver Operating Characteristics analysis to detect hyperglycemia using the FSP was 43 mg/dL with a sensitivity (Se) and specificity (Sp) of 76 and 80%. Using the GLX and WGC optimized thresholds were 49 mg/dL (Se = 92%, Sp = 85%) and 95 mg/dL (Se = 39%, Sp = 92%). The results of this study demonstrate good performance characteristics for the GLX

  14. High-z Universe with Gamma Ray Bursts

    Science.gov (United States)

    Kouveliotou, C.

    2011-01-01

    Gamma-Ray Bursts (GRBs) are the most luminous explosions in space and trace the cosmic star formation history back to the first generations of stars. Their bright afterglows allow us to trace the abundances of heavy elements to large distances, thereby measuring cosmic chemical evolution. To date GRBs have been detected up to distances of z=8.23 and possibly even beyond z9. This makes GRBs a unique and powerful tool to probe the high-z Universe up to the re-ionization era. We discuss the current status of the field, place it in context with other probes, and also discuss new mission concepts that have been planned to utilize GRBs as probes.

  15. Large-scale anisotropy in the extragalactic gamma-ray background as a probe for cosmological antimatter

    Science.gov (United States)

    Gao, Yi-Tian; Stecker, Floyd W.; Gleiser, Marcelo; Cline, David B.

    1990-01-01

    Intrinsic anisotropies in the extragalactic gamma-ray background (EGB), which should be detectable with the forthcoming Gamma Ray Observatory, can be used to examine some of the mechanisms proposed to explain its origin, one of which, the baryon-symmetric big bang (BSBB) model, is investigated here. In this simulation, large domains containing matter and antimatter galaxies produce gamma rays by annihilation at the domain boundaries. This mechanism can produce mountain-chain-shaped angular fluctuations in the EGB flux.

  16. Fermi Detection of a Luminous gamma-ray Pulsar in a Globular Cluster

    Science.gov (United States)

    Freire, P. C. C.; Abdo, A. A.; Ajello, M.; Allafort, A.; Ballet, J.; Barbiellini, G.; Bastieri, D.; Bechtol, K.; Bellazzini, R.; Blandford, R. D.; hide

    2011-01-01

    We report the Fermi Large Area Telescope detection of gamma -ray (>100 mega-electron volts) pulsations from pulsar J1823--3021A in the globular cluster NGC 6624 with high significance (approx 7 sigma). Its gamma-ray luminosity L (sub 3) = (8:4 +/- 1:6) X 10(exp 34) ergs per second, is the highest observed for any millisecond pulsar (MSP) to date, and it accounts for most of the cluster emission. The non-detection of the cluster in the off-pulse phase implies that its contains < 32 gamma-ray MSPs, not approx 100 as previously estimated. The gamma -ray luminosity indicates that the unusually large rate of change of its period is caused by its intrinsic spin-down. This implies that J1823--3021A has the largest magnetic field and is the youngest MSP ever detected, and that such anomalous objects might be forming at rates comparable to those of the more normal MSPs.

  17. Hand-held personnel and vehicle monitors

    International Nuclear Information System (INIS)

    Kunz, W.E.; Chambers, W.H.; Henry, C.N.; France, S.W.; Millegan, D.R.; Hastings, R.D.; Worth, G.M.

    1976-05-01

    A light, rugged monitor has been developed for special nuclear materials (SNM) searches at material-access and protection-area exits. This monitor accepts gamma-ray pulses from a NaI(Tl) detector, integrates for a preset counting interval (typically 0.3 s), and produces an audible alarm whenever the counts in the interval exceed the trip level that is a preset multiple of the stored background count. Because the monitor is silent except when the alarm is operating, personnel with little special training can conduct more effective searches in a noisy and distracting environment than they can with conventional audible monitoring of individual radiation counts. The monitor is also more sensitive than conventional monitors that provide audible indication of the count rate

  18. The use of hand-held 35 mm color infrared imagery for estimates of suspended solids - A progress report. [in water pollution monitoring

    Science.gov (United States)

    Miller, W. F.; Whisler, F. D.; Robinette, H. R.; Finnie, D.; Cannon, T.

    1975-01-01

    A cost-effective aerial surveillance technique is proposed for detection and identification of suspended solids which would be operational for both governmental monitoring organizations and private individuals operating catfish farms. Sixteen catfish ponds were flown daily for seven days using two hand-held 35 mm cameras with both Kodachrome X and Ektachrome infrared film. Hue, value, and chroma designations were recorded for each pond on each date by three interpreters, and the accepted color was that recorded by at least two of the interpreters, or if there was a three hue range, the median was accepted. Relations between suspended solids and color designations were analyzed graphically, and chroma was discarded due to an apparent lack of correlation. The data obtained were then analyzed by multiple regression. Significant correlations were revealed between hue and value and total and inorganic suspended solids. If perfected, this technique could be developed to sufficent accuracy for large-scale reconnaissance surveys to monitor the quality of rivers and streams.

  19. Detection of hepatitis A virus by hybridization with single-stranded RNA probes

    International Nuclear Information System (INIS)

    Xi, J.; Estes, M.K.; Metcalf, T.G.

    1987-01-01

    An improved method of dot-blot hybridization to detect hepatitis A virus (HAV) was developed with single-stranded RNA (ssRNA) probes. Radioactive and nonradioactive ssRNA probes were generated by in vitro transcription of HAV templates inserted into the plasmid pGEM-1. 32 P-labeled ssRNA probes were at least eightfold more sensitive than the 32 P-labeled double-stranded cDNA counterparts, whereas biotin-labeled ssRNA probes showed a sensitivity comparable with that of the 32 P-labeled double-stranded cDNA counterparts. Hybridization of HAV with the ssRNA probes at high stringency revealed specific reactions with a high signal-to-noise ratio. The differential hybridization reactions seen with probes of positive and negative sense (compared with HAV genomic RNA) were used to detect HAV in clinical and field samples. A positive/negative ratio was introduced as an indicator that permitted an semiquantitative expression of a positive HAV reaction. Good agreement of this indicator was observed with normal stool samples and with HAV-seeded samples. By using this system, HAV was detected in estuarine and freshwater samples collected from a sewage-polluted bayou in Houston and a saltwater tributary of Galveston Bay

  20. An efficient probe for rapid detection of cyanide in water at parts per billion levels and naked-eye detection of endogenous cyanide.

    Science.gov (United States)

    Kumari, Namita; Jha, Satadru; Bhattacharya, Santanu

    2014-03-01

    A new molecular probe based on an oxidized bis-indolyl skeleton has been developed for rapid and sensitive visual detection of cyanide ions in water and also for the detection of endogenously bound cyanide. The probe allows the "naked-eye" detection of cyanide ions in water with a visual color change from red to yellow (Δλmax =80 nm) with the immediate addition of the probe. It shows high selectivity towards the cyanide ion without any interference from other anions. The detection of cyanide by the probe is ratiometric, thus making the detection quantitative. A Michael-type addition reaction of the probe with the cyanide ion takes place during this chemodosimetric process. In water, the detection limit was found to be at the parts per million level, which improved drastically when a neutral micellar medium was employed, and it showed a parts-per-billion-level detection, which is even 25-fold lower than the permitted limits of cyanide in water. The probe could also efficiently detect the endogenously bound cyanide in cassava (a staple food) with a clear visual color change without requiring any sample pretreatment and/or any special reaction conditions such as pH or temperature. Thus the probe could serve as a practical naked-eye probe for "in-field" experiments without requiring any sophisticated instruments. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Inter-Tester Reliability and Precision of Manual Muscle Testing and Hand-Held Dynamometry in Lower Limb Muscles of Children with Spina Bifida

    Science.gov (United States)

    Mahony, Kate; Hunt, Adrienne; Daley, Deborah; Sims, Susan; Adams, Roger

    2009-01-01

    Reliability and measurement precision of manual muscle testing (MMT) and hand-held dynamometry (HHD) were compared for children with spina bifida. Strength measures were obtained of the hip flexors, hip abductors, and knee extensors of 20 children (10 males, 10 females; mean age 9 years 10 months; range: 5 to 15 years) by two experienced physical…

  2. Sentinel lymph node detection with Tc-99m tin colloids in patients with esophagogastric cancer

    International Nuclear Information System (INIS)

    Yasuda, Seiei; Shimada, Hideo; Chino, Osamu

    2003-01-01

    The aim of this study was to determine by radioisotope use whether the sentinel lymph node concept is applicable to esophagogastric cancers. In addition, we examined radioactivities of hot nodes and compared them with the sensitivity of a gamma probe. The subjects were 44 patients, 23 with esophageal cancer and 21 with gastric cancer. The day before surgery, patients underwent endoscopic submucosal injection of 184 MBq of Tc-99m tin colloids into sites surrounding the tumor. Radioisotope activities of lymph nodes dissected at surgery were measured with a well-typed gamma detector and each lymph node was categorized as a hot or cold node. Histopathology of the lymph nodes was examined by hematoxylin and eosin staining. Radioisotope activities and histopathological results were compared to determine whether radioisotope flow reflects lymphatic flow to regional lymph nodes. The sensitivity of a gamma probe was measured in a laboratory study and the relation between the radioisotope activities of hot nodes and the detection sensitivity of the gamma probe was examined. Histopathological examination revealed lymph node metastasis in 18 of the 44 patients. In 15 of these 18 patients, metastatic foci were recognized in at least one hot node. Subsequent analysis was performed on the 36 patients in whom tumor invasion was confined to the muscle layer and in whom endoscopic clippings had not been applied. Lymph node metastases were observed in 12 of these 36 patients. In these 12 patients, at least one hot node was positive for metastasis. The laboratory study revealed that the gamma probe was able to detect radioisotope activities of ≥0.02μCi. Thirty-two of 63 (51%) esophageal cancer hot nodes and 16 of 86 (19%) gastric cancer hot nodes showed radioisotope activities below the detection sensitivity of the gamma probe. The sentinel lymph node concept is applicable to patients with esophageal and gastric cancers; however, further studies are necessary to identify hot nodes

  3. Development of software for the determination of gamma ray detection efficiency

    International Nuclear Information System (INIS)

    Silva, Antonio C.O. da; Genezini, Frederico A.; Zahn, Guilherme S.

    2009-01-01

    Gamma spectrometry is frequently used as a tool in analytical chemistry or environmental analyses. The efficiency of the detection setup is one of most important steps of the analyses, but users don't always calculate their own efficiency curve because this procedure is not trivial, and therefore they adapt their measurement geometry to work in a setup that has been previously calibrated, which will often cause limitations. In order to solve this problem, a software was developed that helps a non-experienced user to compute the detection efficiency curve and to determine the detection efficiency at a given gamma-ray energy. (author)

  4. Gamma-ray bursts as cosmological probes: ΛCDM vs. conformal gravity

    International Nuclear Information System (INIS)

    Diaferio, Antonaldo; Ostorero, Luisa; Cardone, Vincenzo

    2011-01-01

    ΛCDM, for the currently preferred cosmological density Ω 0 and cosmological constant Ω Λ , predicts that the Universe expansion decelerates from early times to redshift z ≈ 0.9 and accelerates at later times. On the contrary, the cosmological model based on conformal gravity predicts that the cosmic expansion has always been accelerating. To distinguish between these two very different cosmologies, we resort to gamma-ray bursts (GRBs), which have been suggested to probe the Universe expansion history at z > 1, where identified type Ia supernovae (SNe) are rare. We use the full Bayesian approach to infer the cosmological parameters and the additional parameters required to describe the GRB data available in the literature. For the first time, we use GRBs as cosmological probes without any prior information from other data. In addition, when we combine the GRB samples with SNe, our approach neatly avoids all the inconsistencies of most numerous previous methods that are plagued by the so-called circularity problem. In fact, when analyzed properly, current data are consistent with distance moduli of GRBs and SNe that can respectively be, in a variant of conformal gravity, ∼ 15 and ∼ 3 magnitudes fainter than in ΛCDM. Our results indicate that the currently available SN and GRB samples are accommodated equally well by both ΛCDM and conformal gravity and do not exclude a continuous accelerated expansion. We conclude that GRBs are currently far from being effective cosmological probes, as they are unable to distinguish between these two very different expansion histories

  5. Gamma-ray spectrometry applied to down-hole logging

    International Nuclear Information System (INIS)

    Dumesnil, P.; Umiastowsky, K.

    1983-11-01

    Gamma-ray spectrometry permits to improve the accuracy of natural gamma, gamma-gamma and neutron-gamma geophysical measurements. The probe developed at Centre d'Etudes Nucleaires de Saclay allows down-hole gamma-ray spectrometry. Among others, this probe can be applied to the uranium content determination by selective natural gamma method, down-hole determination of the ash content in the coal by gamma-gamma selective method and elemental analysis by neutron-gamma method. For the calibration and an exact interpretation of the measurements it is important to know the gamma-ray and neutron characteristics of the different kinds of rocks considered as probabilistic variables

  6. Current trends in gamma radiation detection for radiological emergency response

    Science.gov (United States)

    Mukhopadhyay, Sanjoy; Guss, Paul; Maurer, Richard

    2011-09-01

    Passive and active detection of gamma rays from shielded radioactive materials, including special nuclear materials, is an important task for any radiological emergency response organization. This article reports on the current trends and status of gamma radiation detection objectives and measurement techniques as applied to nonproliferation and radiological emergencies. In recent years, since the establishment of the Domestic Nuclear Detection Office by the Department of Homeland Security, a tremendous amount of progress has been made in detection materials (scintillators, semiconductors), imaging techniques (Compton imaging, use of active masking and hybrid imaging), data acquisition systems with digital signal processing, field programmable gate arrays and embedded isotopic analysis software (viz. gamma detector response and analysis software [GADRAS]1), fast template matching, and data fusion (merging radiological data with geo-referenced maps, digital imagery to provide better situational awareness). In this stride to progress, a significant amount of inter-disciplinary research and development has taken place-techniques and spin-offs from medical science (such as x-ray radiography and tomography), materials engineering (systematic planned studies on scintillators to optimize several qualities of a good scintillator, nanoparticle applications, quantum dots, and photonic crystals, just to name a few). No trend analysis of radiation detection systems would be complete without mentioning the unprecedented strategic position taken by the National Nuclear Security Administration (NNSA) to deter, detect, and interdict illicit trafficking in nuclear and other radioactive materials across international borders and through the global maritime transportation-the so-called second line of defense.

  7. Absolute peak detection efficiencies of a Ge(Li) detector for high gamma-ray energies

    International Nuclear Information System (INIS)

    Katagiri, Masaki

    1985-11-01

    Absolute peak detection efficiencies of a Ge(Li) detector for gamma-rays of 3.5 MeV to 12 MeV were measured using four (p,γ) reactions and a (n,γ) reaction. Two-line-method was used to obtaine peak detection efficiencies. The efficiencies with the both cases are agreed very well. Utilization of (n,γ) reaction is, therefore, effective for measuring these efficiencies, because high energy gamma-rays can be generated easily by using a neutron source. These results were applied to calibration of a gamma-ray standard source, emitting 6.13 MeV gamma-rays, and of intensities of 56 Co standard gamma-ray source. (author)

  8. Patterning a hydrogen-bonded molecular monolayer with a hand-controlled scanning probe microscope

    Directory of Open Access Journals (Sweden)

    Matthew F. B. Green

    2014-10-01

    Full Text Available One of the paramount goals in nanotechnology is molecular-scale functional design, which includes arranging molecules into complex structures at will. The first steps towards this goal were made through the invention of the scanning probe microscope (SPM, which put single-atom and single-molecule manipulation into practice for the first time. Extending the controlled manipulation to larger molecules is expected to multiply the potential of engineered nanostructures. Here we report an enhancement of the SPM technique that makes the manipulation of large molecular adsorbates much more effective. By using a commercial motion tracking system, we couple the movements of an operator's hand to the sub-angstrom precise positioning of an SPM tip. Literally moving the tip by hand we write a nanoscale structure in a monolayer of large molecules, thereby showing that our method allows for the successful execution of complex manipulation protocols even when the potential energy surface that governs the interaction behaviour of the manipulated nanoscale object(s is largely unknown.

  9. Performance of hand-held whole-breast ultrasound based on BI-RADS in women with mammographically negative dense breast

    International Nuclear Information System (INIS)

    Youk, Ji Hyun; Kim, Eun-Kyung; Kim, Min Jung; Kwak, Jin Young; Son, Eun Ju

    2011-01-01

    To assess the performance of breast ultrasound based on BI-RADS final assessment categories in women with mammographically negative dense breast. Of 3,820 cases with mammographically negative dense breast and subsequent hand-held bilateral whole-breast ultrasound, a total of 1,507 cases in 1,046 women who had biopsy or at least 2-year follow-up ultrasound constituted the basis of this retrospective study. Cancer rate of each sonographic BI-RADS category was determined and medical audit was performed separately in screening-general, screening-treated, and diagnostic group. A total of 43 cases (2.9%) were confirmed as malignancy. Cancer rate among BI-RADS categories was significantly different (p < 0.0001). Among three groups, the cancer rate was significantly different (p < 0.0001) and the highest in diagnostic group (15.8%, 22 of 139). Abnormal interpretation rate, PPV of biopsy performed, cancer detection rate, and rate of early stage cancer, and the size of invasive cancer were significantly different among three groups and the highest in diagnostic group. Regarding cancer characteristics, the proportion of advanced cancer was the highest in diagnostic group. Breast ultrasound based on BI-RADS as an adjunctive to negative mammography can be useful for predicting malignancy in women with dense breast. (orig.)

  10. Molecularly imprinted fluorescent probe based on FRET for selective and sensitive detection of doxorubicin

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Zhifeng, E-mail: 897061147@qq.com [College of Chemistry and Materials Science, Hengyang Normal University, Key Laboratory of Functional Organometallic Materials of Hunan Province University, Hengyang 421008 (China); Deng, Peihong; Li, Junhua [College of Chemistry and Materials Science, Hengyang Normal University, Key Laboratory of Functional Organometallic Materials of Hunan Province University, Hengyang 421008 (China); Xu, Li [Department of Applied Chemistry, College of Materials and Energy, South China Agricultural University, Guangzhou 510642 (China); Tang, Siping [College of Chemistry and Materials Science, Hengyang Normal University, Key Laboratory of Functional Organometallic Materials of Hunan Province University, Hengyang 421008 (China)

    2017-04-15

    Highlights: • FRET-based molecularly imprinted probe for detection of doxorubicin was prepared. • The detection limit of the probe was 13.8 nM for doxorubicin. • The FRET-based probe had a higher selectivity for the template than ordinary MIMs. - Abstract: In this work, a new type of fluorescent probe for detection of doxorubicin has been constructed by the combined use of fluorescence resonance energy transfer (FRET) technology and molecular imprinting technique (MIT). Using doxorubicin as the template, the molecularly imprinted polymer thin layer was fabricated on the surfaces of carbon dot (CD) modified silica by sol-gel polymerization. The excitation energy of the fluorescent donor (CDs) could be transferred to the fluorescent acceptor (doxorubicin). The FRET based fluorescent probe demonstrated high sensitivity and selectivity for doxorubicin. The detection limit was 13.8 nM. The fluorescent probe was successfully applied for detecting doxorubicin in doxorubicin-spiked plasmas with a recovery of 96.8–103.8%, a relative standard deviation (RSD) of 1.3–2.8%. The strategy for construction of FRET-based molecularly imprinted materials developed in this work is very promising for analytical applications.

  11. A benzothiazole-based fluorescent probe for hypochlorous acid detection and imaging in living cells

    Science.gov (United States)

    Nguyen, Khac Hong; Hao, Yuanqiang; Zeng, Ke; Fan, Shengnan; Li, Fen; Yuan, Suke; Ding, Xuejing; Xu, Maotian; Liu, You-Nian

    2018-06-01

    A benzothiazole-based turn-on fluorescent probe with a large Stokes shift (190 nm) has been developed for hypochlorous acid detection. The probe displays prompt fluorescence response for HClO with excellent selectivity over other reactive oxygen species as well as a low detection limit of 0.08 μM. The sensing mechanism involves the HClO-induced specific oxidation of oxime moiety of the probe to nitrile oxide, which was confirmed by HPLC-MS technique. Furthermore, imaging studies demonstrated that the probe is cell permeable and can be applied to detect HClO in living cells.

  12. Salience Is Only Briefly Represented: Evidence from Probe-Detection Performance

    Science.gov (United States)

    Donk, Mieke; Soesman, Leroy

    2010-01-01

    Salient objects in the visual field tend to capture attention. The present study aimed to examine the time-course of salience effects using a probe-detection task. Eight experiments investigated how the salience of different orientation singletons affected probe reaction time as a function of stimulus onset asynchrony (SOA) between the…

  13. Hypercharged dark matter and direct detection as a probe of reheating.

    Science.gov (United States)

    Feldstein, Brian; Ibe, Masahiro; Yanagida, Tsutomu T

    2014-03-14

    The lack of new physics at the LHC so far weakens the argument for TeV scale thermal dark matter. On the other hand, heavier, nonthermal dark matter is generally difficult to test experimentally. Here we consider the interesting and generic case of hypercharged dark matter, which can allow for heavy dark matter masses without spoiling testability. Planned direct detection experiments will be able to see a signal for masses up to an incredible 1010  GeV, and this can further serve to probe the reheating temperature up to about 109  GeV, as determined by the nonthermal dark matter relic abundance. The Z-mediated nature of the dark matter scattering may be determined in principle by comparing scattering rates on different detector nuclei, which in turn can reveal the dark matter mass. We will discuss the extent to which future experiments may be able to make such a determination.

  14. Bifunctional fluorescent probes for detection of amyloid aggregates and reactive oxygen species.

    Science.gov (United States)

    Needham, Lisa-Maria; Weber, Judith; Fyfe, James W B; Kabia, Omaru M; Do, Dung T; Klimont, Ewa; Zhang, Yu; Rodrigues, Margarida; Dobson, Christopher M; Ghandi, Sonia; Bohndiek, Sarah E; Snaddon, Thomas N; Lee, Steven F

    2018-02-01

    Protein aggregation into amyloid deposits and oxidative stress are key features of many neurodegenerative disorders including Parkinson's and Alzheimer's disease. We report here the creation of four highly sensitive bifunctional fluorescent probes, capable of H 2 O 2 and/or amyloid aggregate detection. These bifunctional sensors use a benzothiazole core for amyloid localization and boronic ester oxidation to specifically detect H 2 O 2 . We characterized the optical properties of these probes using both bulk fluorescence measurements and single-aggregate fluorescence imaging, and quantify changes in their fluorescence properties upon addition of amyloid aggregates of α-synuclein and pathophysiological H 2 O 2 concentrations. Our results indicate these new probes will be useful to detect and monitor neurodegenerative disease.

  15. Bifunctional fluorescent probes for detection of amyloid aggregates and reactive oxygen species

    Science.gov (United States)

    Needham, Lisa-Maria; Weber, Judith; Fyfe, James W. B.; Kabia, Omaru M.; Do, Dung T.; Klimont, Ewa; Zhang, Yu; Rodrigues, Margarida; Dobson, Christopher M.; Ghandi, Sonia; Bohndiek, Sarah E.; Snaddon, Thomas N.; Lee, Steven F.

    2018-02-01

    Protein aggregation into amyloid deposits and oxidative stress are key features of many neurodegenerative disorders including Parkinson's and Alzheimer's disease. We report here the creation of four highly sensitive bifunctional fluorescent probes, capable of H2O2 and/or amyloid aggregate detection. These bifunctional sensors use a benzothiazole core for amyloid localization and boronic ester oxidation to specifically detect H2O2. We characterized the optical properties of these probes using both bulk fluorescence measurements and single-aggregate fluorescence imaging, and quantify changes in their fluorescence properties upon addition of amyloid aggregates of α-synuclein and pathophysiological H2O2 concentrations. Our results indicate these new probes will be useful to detect and monitor neurodegenerative disease.

  16. Label-free fluorescence strategy for sensitive detection of adenosine triphosphate using a loop DNA probe with low background noise.

    Science.gov (United States)

    Lin, Chunshui; Cai, Zhixiong; Wang, Yiru; Zhu, Zhi; Yang, Chaoyong James; Chen, Xi

    2014-07-15

    A simple, rapid, label-free, and ultrasensitive fluorescence strategy for adenosine triphosphate (ATP) detection was developed using a loop DNA probe with low background noise. In this strategy, a loop DNA probe, which is the substrate for both ligation and digestion enzyme reaction, was designed. SYBR green I (SG I), a double-stranded specific dye, was applied for the readout fluorescence signal. Exonuclease I (Exo I) and exonuclease III (Exo III), sequence-independent nucleases, were selected to digest the loop DNA probe in order to minimize the background fluorescence signal. As a result, in the absence of ATP, the loop DNA was completely digested by Exo I and Exo III, leading to low background fluorescence owing to the weak electrostatic interaction between SG I and mononucleotides. On the other hand, ATP induced the ligation of the nicking site, and the sealed loop DNA resisted the digestion of Exo I and ExoIII, resulting in a remarkable increase of fluorescence response. Upon background noise reduction, the sensitivity of the ATP determination was improved significantly, and the detection limitation was found to be 1.2 pM, which is much lower than that in almost all the previously reported methods. This strategy has promise for wide application in the determination of ATP.

  17. Detecting the effects of toxic agents on spermatogenesis using DNA probes

    International Nuclear Information System (INIS)

    Hecht, N.B.

    1987-01-01

    Advances in the molecular biology of spermatogenesis suggest that DNA probes can be used to monitor the effects of toxic agents in male germ cells of mammals. Molecular hybridization analyses with DNA probes can provide a reproducible methodology capable of detecting changes ranging from massive deletions to single base pair substitutions in the genome of exposed individuals. A constantly increasing number of DNA probes that can be used to detect such alterations in human sperm DNA exist for both ubiquitously expressed proteins and for genes solely expressed in the testis. In this chapter, the currently available testicular stage-specific and/or cell type-specific DNA probes and the techniques by which they can be utilized in reproductive toxicology studies are discussed. The advantages, limitations, and future technological advances of this novel biological marker system for the human male reproductive system are also considered

  18. A novel polymer probe for Zn(II) detection with ratiometric fluorescence signal

    Science.gov (United States)

    Diao, Haipeng; Guo, Lixia; Liu, Wen; Feng, Liheng

    2018-05-01

    A conjugated polymer probe comprised of fluorene, quinolone and benzothiazole units was designed and synthesized by the Suzuki coupling reaction. Through the studies of photophysical and thermal properties, the polymer displays blue-emitting feature and good thermal stability. A ratiometric fluorescence signal of the probe for Zn(II) was observed in ethanol with a new emission peak at 555 nm. The probe possesses a high selectivity and sensitivity for Zn(II) during familiar metal ions in ethanol. The detection limit of the probe for Zn (II) is up to 10-8 mol/L. The electron distributions of the polymer before and after bonding with Zn (II) were investigated by the Gaussian 09 software, which agreed with the experimental results. Noticeably, based on the color property of the probe with Zn(II), a series of color test paper were developed for visual detecting Zn(II) ions. This work helps to provide a platform or pattern for the development of polymer fluorescence probe in the chemosensor field.

  19. Radioactive and enzymatic cloned cDNA probes for bovine enteric coronavirus detection by molecular hybridization

    International Nuclear Information System (INIS)

    Collomb, J.; Finance, C.; Alabouch, S.; Laporte, J.

    1992-01-01

    Genomic RNA of F15 strain bovine enteric coronavirus (BECV) was cloned in E. coli. Three clones (174, 160, PG 78), selected in the cDNA library, including a large portion of the nucleocapsid (N), matrix (M) and peplomeric (S) protein genes , were used as probes for a slot blot hybridization assay. Two probe labelling techniques were compared, radiolabelling with 32 P and enzymatic labelling through covalent linkage to peroxidase and chemiluminescence detection. The radioactive probe 174 detected as little as 1 to 3 pg of viral RNA, while the less sensitive enzymatic probe could not reveal more than 100 pg of RNA. No significant detection amplification was achieved when a mixture of the three probes was used. Probe 174 allowed specific identification for BECV. No hybridization was noticed either with rotaviruses or even with other antigenically unrelated members of the family Coronaviridae such as transmissible gastroenteritis virus. The test proved valid for detection of BECV in the supernatant of infected HRT-18 cells: genomic RNA could be detected after direct spotting of samples, but prior nucleic acid extraction after proteinase K treatment improved virus detection. BECV diagnosis in faecal samples using enzymatic probe was compared with conventional diagnostic methods. (authors)

  20. Radioactive and enzymatic cloned cDNA probes for bovine enteric coronavirus detection by molecular hybridization

    Energy Technology Data Exchange (ETDEWEB)

    Collomb, J; Finance, C; Alabouch, S [Lab. de Microbiologie Moleculaire, Faculte des Sciences Pharmaceutiques et Biologiques, Univ. de Nancy I, Nancy (France); Laporte, J [Station de Virologie et d' Immunologie Moleculaires, INRA, Jouy-en-Josas (France)

    1992-01-01

    Genomic RNA of F15 strain bovine enteric coronavirus (BECV) was cloned in E. coli. Three clones (174, 160, PG 78), selected in the cDNA library, including a large portion of the nucleocapsid (N), matrix (M) and peplomeric (S) protein genes , were used as probes for a slot blot hybridization assay. Two probe labelling techniques were compared, radiolabeled with [sup 32]P and enzymatic labeled through covalent linkage to peroxidase for chemiluminescence detection. The radioactive probe 174 detected as little as 1-3 pg of viral RNA, while the less sensitive enzymatic probe could not reveal more than 100 pg of RNA. No significant detection amplification was achieved when a mixture of the three probes was used. Probe 174 allowed specific identification for BECV. No hybridization was noticed either with rotaviruses or even with other antigenically unrelated members of the family Coronaviridae such as transmissible gastroenteritis virus. The test proved valid for detection of BECV in the supernatant of infected HRT-18 cells: genomic RNA could be detected after direct spotting of samples, but prior nucleic acid extraction after proteinase K treatment improved virus detection. BECV diagnosis in fecal samples using enzymatic probe was compared with conventional diagnostic methods. (authors).

  1. Minimum Detectable Activity for Tomographic Gamma Scanning System

    Energy Technology Data Exchange (ETDEWEB)

    Venkataraman, Ram [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Smith, Susan [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Kirkpatrick, J. M. [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Croft, Stephen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    For any radiation measurement system, it is useful to explore and establish the detection limits and a minimum detectable activity (MDA) for the radionuclides of interest, even if the system is to be used at far higher values. The MDA serves as an important figure of merit, and often a system is optimized and configured so that it can meet the MDA requirements of a measurement campaign. The non-destructive assay (NDA) systems based on gamma ray analysis are no exception and well established conventions, such the Currie method, exist for estimating the detection limits and the MDA. However, the Tomographic Gamma Scanning (TGS) technique poses some challenges for the estimation of detection limits and MDAs. The TGS combines high resolution gamma ray spectrometry (HRGS) with low spatial resolution image reconstruction techniques. In non-imaging gamma ray based NDA techniques measured counts in a full energy peak can be used to estimate the activity of a radionuclide, independently of other counting trials. However, in the case of the TGS each “view” is a full spectral grab (each a counting trial), and each scan consists of 150 spectral grabs in the transmission and emission scans per vertical layer of the item. The set of views in a complete scan are then used to solve for the radionuclide activities on a voxel by voxel basis, over 16 layers of a 10x10 voxel grid. Thus, the raw count data are not independent trials any more, but rather constitute input to a matrix solution for the emission image values at the various locations inside the item volume used in the reconstruction. So, the validity of the methods used to estimate MDA for an imaging technique such as TGS warrant a close scrutiny, because the pair-counting concept of Currie is not directly applicable. One can also raise questions as to whether the TGS, along with other image reconstruction techniques which heavily intertwine data, is a suitable method if one expects to measure samples whose activities

  2. Detection of pseudo gamma-ray bursts of long duration

    International Nuclear Information System (INIS)

    Frontera, F.; Fuligni, F.; Morelli, E.; Pizzichini, G.; Ventura, G.

    1981-01-01

    It is known that the counting rate of both Na I and Cs I hard X-ray detectors can have intense enhancements of brief (< 1 s) duration, which appear like very short cosmic gamma-ray bursts but probably are due to phosphorescence in the detector itself. Unfortunately, this problem is not limited to short bursts. We present here three much longer (up to 80 s) pseudo-gamma-ray bursts observed during a transatlantic balloon flight. We conclude that detections of gamma-ray bursts (and probably also of hard X-ray source flares) based only on a rate increase by a single scintillator should always be confirmed by at least one other instrument. (orig.)

  3. Detection of 16 Gamma-Ray Pulsars Through Blind Frequency Searches Using the Fermi LAT

    International Nuclear Information System (INIS)

    Anderson, B.; Atwood, W.B.; Dormody, M.; Johnson, R.P.; Porter, T.A.; Primack, J.R.; Sadrozinski, H.F.W.; Parkinson, P.M.S.; Ziegler, M.; Abdo, A.A.; Dermer, C.D.; Grove, J.E.; Gwon, C.; Johnson, W.N.; Lovellette, M.N.; Makeev, A.; Ray, P.S.; Strickman, M.S.; Wolff, M.T.; Wood, K.S.; Ackermann, M.; Ajello, M.; Bechtol, K.; Berenji, B.; Blandford, R.D.; Borgland, A.W.; Cameron, R.A.; Chiang, J.; Claus, R.; Digel, S.W.; Silva, E.D.E.; Drell, P.S.; Dubois, R.; Funk, S.; Glanzman, T.; Godfrey, G.; Hayashida, M.; Johannesson, G.; Kamae, T.; Kocian, M.L.; Lande, J.; Madejski, G.M.; Michelson, P.F.; Mitthumsiri, W.; Monzani, M.E.; Moskalenko, I.V.; Murgia, S.; Nolan, P.L.; Paneque, D.; Reimer, A.; Reimer, O.; Rochester, L.S.; Romani, R.W.; Tajima, H.; Tanaka, T.; Thayer, J.G.; Tramacere, A.; Uchiyama, Y.; Usher, T.L.; Van Etten, A.; Waite, A.P.; Wang, P.; Watters, K.; Ackermann, M.; Ajello, M.; Bechtol, K.; Berenji, B.; Bloom, E.D.; Borgland, A.W.; Cameron, R.A.; Chiang, J.; Claus, R.; Digel, S.W.; Silva, E.D.E.; Drell, P.S.; Dubois, R.; Glanzman, T.; Godfrey, G.; Hayashida, M.; Johannesson, G.; Kamae, T.; Kocian, M.L.; Lande, J.; Madejski, G.M.; Michelson, P.F.; Mitthumsiri, W.; Monzani, M.E.; Moskalenko, I.V.; Murgia, S.; Nolan, P.L.; Paneque, D.; Reimer, A.; Reimer, O.; Rochester, L.S.; Romani, R.W.; Tajima, H.; Tanaka, T.; Thayer, J.G.; Tramacere, A.; Uchiyama, Y.; Usher, T.L.; Van Etten, A.; Waite, A.P.; Wang, P.; Watters, K.; Axelsson, M.; Conrad, J.; Meurer, C.; Ryde, F.; Ylinen, T.; Axelsson, M.; Baldini, L.; Bellazzini, R.; Bregeon, J.; Brez, A.; Kuss, M.; Latronico, L.; Omodei, N.; Pesce-Rollins, M.; Razzano, M.; Sgro, C.; Spandre, G.; Ballet, J.; Casandjian, J.M.; Grenier, I.A.; Pierbattista, M.; Starck, J.L.

    2009-01-01

    Pulsars are rapidly rotating, highly magnetized neutron stars emitting radiation across the electromagnetic spectrum. Although there are more than 1800 known radio pulsars, until recently only seven were observed to pulse in gamma rays, and these were all discovered at other wavelengths. The Fermi Large Area Telescope (LAT) makes it possible to pinpoint neutron stars through their gamma-ray pulsations. We report the detection of 16 gamma-ray pulsars in blind frequency searches using the LAT. Most of these pulsars are coincident with previously unidentified gamma-ray sources, and many are associated with supernova remnants. Direct detection of gamma-ray pulsars enables studies of emission mechanisms, population statistics, and the energetics of pulsar wind nebulae and supernova remnants. (authors)

  4. A link between prompt optical and prompt gamma-ray emission in gamma-ray bursts.

    Science.gov (United States)

    Vestrand, W T; Wozniak, P R; Wren, J A; Fenimore, E E; Sakamoto, T; White, R R; Casperson, D; Davis, H; Evans, S; Galassi, M; McGowan, K E; Schier, J A; Asa, J W; Barthelmy, S D; Cummings, J R; Gehrels, N; Hullinger, D; Krimm, H A; Markwardt, C B; McLean, K; Palmer, D; Parsons, A; Tueller, J

    2005-05-12

    The prompt optical emission that arrives with the gamma-rays from a cosmic gamma-ray burst (GRB) is a signature of the engine powering the burst, the properties of the ultra-relativistic ejecta of the explosion, and the ejecta's interactions with the surroundings. Until now, only GRB 990123 had been detected at optical wavelengths during the burst phase. Its prompt optical emission was variable and uncorrelated with the prompt gamma-ray emission, suggesting that the optical emission was generated by a reverse shock arising from the ejecta's collision with surrounding material. Here we report prompt optical emission from GRB 041219a. It is variable and correlated with the prompt gamma-rays, indicating a common origin for the optical light and the gamma-rays. Within the context of the standard fireball model of GRBs, we attribute this new optical component to internal shocks driven into the burst ejecta by variations of the inner engine. The correlated optical emission is a direct probe of the jet isolated from the medium. The timing of the uncorrelated optical emission is strongly dependent on the nature of the medium.

  5. Gamma-Ray Pulsar Studies With GLAST

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, D.J.; /NASA, Goddard

    2011-11-23

    Some pulsars have their maximum observable energy output in the gamma-ray band, offering the possibility of using these high-energy photons as probes of the particle acceleration and interaction processes in pulsar magnetospheres. After an extended hiatus between satellite missions, the recently-launched AGILE mission and the upcoming Gamma-ray Large Area Space Telescope (GLAST) Large Area Telescope (LAT) will allow gamma-ray tests of the theoretical models developed based on past discoveries. With its greatly improved sensitivity, better angular resolution, and larger energy reach than older instruments, GLAST LAT should detect dozens to hundreds of new gamma-ray pulsars and measure luminosities, light curves, and phase-resolved spectra with unprecedented resolution. It will also have the potential to find radio-quiet pulsars like Geminga, using blind search techniques. Cooperation with radio and X-ray pulsar astronomers is an important aspect of the LAT team's planning for pulsar studies.

  6. Assessment of isometric muscle strength and rate of torque development with hand-held dynamometry: Test-retest reliability and relationship with gait velocity after stroke.

    Science.gov (United States)

    Mentiplay, Benjamin F; Tan, Dawn; Williams, Gavin; Adair, Brooke; Pua, Yong-Hao; Bower, Kelly J; Clark, Ross A

    2018-04-27

    Isometric rate of torque development examines how quickly force can be exerted and may resemble everyday task demands more closely than isometric strength. Rate of torque development may provide further insight into the relationship between muscle function and gait following stroke. Aims of this study were to examine the test-retest reliability of hand-held dynamometry to measure isometric rate of torque development following stroke, to examine associations between strength and rate of torque development, and to compare the relationships of strength and rate of torque development to gait velocity. Sixty-three post-stroke adults participated (60 years, 34 male). Gait velocity was assessed using the fast-paced 10 m walk test. Isometric strength and rate of torque development of seven lower-limb muscle groups were assessed with hand-held dynamometry. Intraclass correlation coefficients were calculated for reliability and Spearman's rho correlations were calculated for associations. Regression analyses using partial F-tests were used to compare strength and rate of torque development in their relationship with gait velocity. Good to excellent reliability was shown for strength and rate of torque development (0.82-0.97). Strong associations were found between strength and rate of torque development (0.71-0.94). Despite high correlations between strength and rate of torque development, rate of torque development failed to provide significant value to regression models that already contained strength. Assessment of isometric rate of torque development with hand-held dynamometry is reliable following stroke, however isometric strength demonstrated greater relationships with gait velocity. Further research should examine the relationship between dynamic measures of muscle strength/torque and gait after stroke. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. A simple rhodamine hydrazide-based turn-on fluorescent probe for HOCl detection.

    Science.gov (United States)

    Zhang, Zhen; Zou, Yuan; Deng, Chengquan; Meng, Liesu

    2016-06-01

    Hypochlorous acid (HOCl) plays a crucial role in daily life and mediates a variety of physiological processes, however, abnormal levels of HOCl have been associated with numerous human diseases. It is therefore of significant interest to establish a simple, selective, rapid and sensitive fluorogenic method for the detection of HOCl in environmental and biological samples. A hydrazide-containing fluorescent probe based on a rhodamine scaffold was facilely developed that could selectively detect HOCl over other biologically relevant reactive oxygen species, reactive nitrogen species and most common metal ions in vitro. Via an irreversible oxidation-hydrolysis mechanism, and upon HOCl-triggered opening of the intramolecular spirocyclic ring during detection, the rhodamine hydrazide-based probe exhibited large fluorescence enhancement in the emission spectra with a fast response, low detection limit and comparatively wide pH detection range in aqueous media. The probe was further successfully applied to monitoring trace HOCl in tap water and imaging both exogenous and endogenous HOCl within living cells. It is anticipated that this simple and useful probe might be an efficient tool with which to facilitate more HOCl-related chemical and biological research. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  8. Laser-based ultrasonics by dual-probe interferometer detection and narrow-band ultrasound generation

    Science.gov (United States)

    Huang, Jin

    1993-01-01

    Despite the advantages of laser-based ultrasonic (LBU) systems, the overall sensitivity of LBU systems needs to be improved for practical applications. Progress is reported to achieve better LBU detection accuracy and sensitivity for applications with surface waves and Lamb waves. A novel dual-probe laser interferometer has been developed to measure the same signal at two points. The dual-probe interferometer is a modification of a conventional single-probe interferometer in that the reference beam is guided to a second detecting point on the specimen surface to form a differential measurement mode, which measure the difference of the displacements at the two points. This dual-probe interferometer is particularly useful for accurate measurements of the speed and attenuation of surface waves and Lamb waves. The dual-probe interferometer has been applied to obtain accurate measurements of the surface wave speed and attenuation on surfaces of increasing surface roughness. It has also been demonstrated that with an appropriate signal processing method, namely, the power cepstrum method, the dual-probe interferometer is applicable to measure the local surface wave speed even when the probe separation is so small that the two waveforms in the interferometer output signal overlap in the time domain. Narrow-band signal generation and detection improve the sensitivity of LBU systems. It is proposed to use a diffraction grating to form an array of illuminating strips which form a source of narrowband surface and Lamb waves. The line-array of thermoelastic sources generates narrow-band signals whose frequency and bandwidth can be easily controlled. The optimum line-array parameters, such as width, spacing and the number of lines in the array have been derived theoretically and verified experimentally. Narrow-band signal generation with optimum parameters has been demonstrated. The enhanced LBU system with dual-probe detection and narrowband signal generation has been

  9. Improvement in minimum detectable activity for low energy gamma by optimization in counting geometry

    Directory of Open Access Journals (Sweden)

    Anil Gupta

    2017-01-01

    Full Text Available Gamma spectrometry for environmental samples of low specific activities demands low minimum detection levels of measurement. An attempt has been made to lower the gamma detection level of measurement by optimizing the sample geometry, without compromising on the sample size. Gamma energy of 50–200 keV range was chosen for the study, since low energy gamma photons suffer the most self-attenuation within matrix. The simulation study was carried out using MCNP based software “EffCalcMC” for silica matrix and cylindrical geometries. A volume of 250 ml sample geometry of 9 cm diameter is optimized as the best suitable geometry for use, against the in-practice 7 cm diameter geometry of same volume. An increase in efficiency of 10%–23% was observed for the 50–200 keV gamma energy range and a corresponding lower minimum detectable activity of 9%–20% could be achieved for the same.

  10. Shielding system for the detection of radioisotopes gamma-rays emitters

    International Nuclear Information System (INIS)

    Nascimento Filho, V.F. do

    1983-01-01

    A shielding system for detection of radioisotopes gamma-rays emitters in samples of big volumes (plants, animals, soils) is presented. The detection between the beaker Marinelli and the glass tube (inside of the scintillator crystal well) is compared. The beaker Marinelli method allows a drastic reduction in the time detection of the sample. (M.A.C.) [pt

  11. Beyond Textbook Illustrations: Hand-Held Models of Ordered DNA and Protein Structures as 3D Supplements to Enhance Student Learning of Helical Biopolymers

    Science.gov (United States)

    Jittivadhna, Karnyupha; Ruenwongsa, Pintip; Panijpan, Bhinyo

    2010-01-01

    Textbook illustrations of 3D biopolymers on printed paper, regardless of how detailed and colorful, suffer from its two-dimensionality. For beginners, computer screen display of skeletal models of biopolymers and their animation usually does not provide the at-a-glance 3D perception and details, which can be done by good hand-held models. Here, we…

  12. Compact and maintenance-free radio probes for environmental surveillance of the gamma dose rate

    International Nuclear Information System (INIS)

    Genrich, V.

    1998-01-01

    The author reports on his experience with the operation of radio data networks for the continuous observation of the gamma dose rate in nuclear installations. Practically at every location (within) the installation the hermetically sealed probes can record the measurement values. Moreover, the probes have proved successful in environmental surveillance where they typically work in the form of measurement rings in 10 to 30 km distance. All measurement data are organized in the form of a data base. They can be disposed of in the form of an SQL-server in the computer network (LAN) of the power plant or the institution in charge of environmental surveillance. In comparison to conventional, e.g. cable-bound measurement networks with the new radio transmission technology there are numerous advantages: - minimal cost for projection - minimal cost for installation due to simple fixing - quasi-mobile use with highest possible flexibility - maintenance-free operation and high degree of operating reliability. (orig.) [de

  13. Detection of tricuspid insufficiency by portable nuclear probe monitoring over the liver

    International Nuclear Information System (INIS)

    Dey, H.M.; Schulman, P.; Smith, V.E.; Karimeddini, M.K.; Spencer, R.P.

    1983-01-01

    A case is presented in which a portable nuclear scintillation probe was used to detect tricuspid regurgitation. An electrocardiographically-gated scintigraphic collection obtained over the liver was correlated with findings from contrast echocardiography and jugular venous pulse tracings. The nuclear probe may provide a simple means for the detection of tricuspid insufficiency. It remains to be determined if quantification of severity will be possible

  14. Gamma and neutron detection modeling in the nuclear detection figure of merit (NDFOM) portal

    International Nuclear Information System (INIS)

    Stroud, Phillip D.; Saeger, Kevin J.

    2009-01-01

    The Nuclear Detection Figure Of Merit (NDFOM) portal is a database of objects and algorithms for evaluating the performance of radiation detectors to detect nuclear material. This paper describes the algorithms used to model the physics and mathematics of radiation detection. As a first-principles end-to-end analysis system, it starts with the representation of the gamma and neutron spectral fluxes, which are computed with the particle and radiation transport code MCNPX. The gamma spectra emitted by uranium, plutonium, and several other materials of interest are described. The impact of shielding and other intervening material is computed by the method of build-up factors. The interaction of radiation with the detector material is computed by a detector response function approach. The construction of detector response function matrices based on MCNPX simulation runs is described in detail. Neutron fluxes are represented in a three group formulation to treat differences in detector sensitivities to thermal, epithermal, and fast neutrons.

  15. A novel dansyl-based fluorescent probe for highly selective detection of ferric ions.

    Science.gov (United States)

    Yang, Min; Sun, Mingtai; Zhang, Zhongping; Wang, Suhua

    2013-02-15

    A novel dansyl-based fluorescent probe was synthesized and characterized. It exhibits high selectivity and sensitivity towards Fe(3+) ion. This fluorescent probe is photostable, water soluble and pH insensitive. The limit of detection is found to be 0.62 μM. These properties make it a good fluorescent probe for Fe(3+) ion detection in both chemical and biological systems. Spike recovery test confirms its practical application in tap water samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Testing of Hand-Held Mine Detection Systems

    Science.gov (United States)

    2015-01-08

    Military Standards (MIL-STD), and if necessary, International Test Operations Procedures (ITOP) and North Atlantic Treaty Organization (NATO...include grass vegetation, loose and compacted ground, virgin ground, controlled wash beds. Allow for a calibration to be available for each type of...MSDS material safety data sheet N North NATO North Atlantic Treaty Organization NBC nuclear, biological, chemical NMMC no metal main charge NMPP

  17. Hand-held multi-DOF robotic forceps for neurosurgery designed for dexterous manipulation in deep and narrow space.

    Science.gov (United States)

    Okubo, Takuro; Harada, Kanako; Fujii, Masahiro; Tanaka, Shinichi; Ishimaru, Tetsuya; Iwanaka, Tadashi; Nakatomi, Hirohumi; Sora, Sigeo; Morita, Akio; Sugita, Naohiko; Mitsuishi, Mamoru

    2014-01-01

    Neurosurgical procedures require precise and dexterous manipulation of a surgical suture in narrow and deep spaces in the brain. This is necessary for surgical tasks such as the anastomosis of microscopic blood vessels and dura mater suturing. A hand-held multi-degree of freedom (DOF) robotic forceps was developed to aid the performance of such difficult tasks. The diameter of the developed robotic forceps is 3.5 mm, and its tip has three DOFs, namely, bending, rotation, and grip. Experimental results showed that the robotic forceps had an average needle insertion force of 1.7 N. Therefore, an increase in the needle insertion force is necessary for practical application of the developed device.

  18. Basics of Gamma Ray Detection

    Energy Technology Data Exchange (ETDEWEB)

    Stinnett, Jacob [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Venkataraman, Ram [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-09-13

    The objective of this training is to explain the origin of x-rays and gamma rays, gamma ray interactions with matter, detectors and electronics used in gamma ray-spectrometry, and features of a gamma-ray spectrum for nuclear material that is safeguarded.

  19. High Sensitivity Detection of Xe Isotopes Via Beta-Gamma Coincidence Counting

    International Nuclear Information System (INIS)

    Bowyer, Ted W.; McIntyre, Justin I.; Reeder, Paul L.

    1999-01-01

    Measurement of xenon fission product isotopes is a key element in the global network being established to monitor the Comprehensive Nuclear-Test-Ban Treaty. Pacific Northwest National Laboratory has developed an automated system for separating Xe from air which includes a beta-gamma counting system for 131mXe, 133mXe, 133Xe, and 135Xe. Betas and conversion electrons are detected in a plastic scintillation cell containing the Xe sample. The counting geometry is nearly 100% for beta and conversion electrons. The resolution in the pulse height spectrum from the plastic scintillator is sufficient to observe distinct peaks for specific conversion electrons. Gamma and X-rays are detected in a NaI(Tl) scintillation detector which surrounds the plastic scintillator sample cell. Two-dimensional pulse height spectra of gamma energy versus beta energy are obtained. Each of the four xenon isotopes has a distinctive signature in the two-dimensional energy array. The details of the counting system, examples of two-dimensional beta-gamma data, and operational experience with this counting system will be described

  20. Rapid identification and detection of pathogenic Fungi by padlock probes

    NARCIS (Netherlands)

    Tsui, C.K.M.; Wang, B.; Schoen, C.D.; Hamelin, R.C.

    2013-01-01

    Fungi are important pathogens of human diseases, as well as to agricultural crop and trees. Molecular diagnostics can detect diseases early, and improve identification accuracy and follow-up disease management. The use of padlock probe is effective to facilitate these detections and pathogen

  1. Methods for radiation detection and characterization using a multiple detector probe

    Science.gov (United States)

    Akers, Douglas William; Roybal, Lyle Gene

    2014-11-04

    Apparatuses, methods, and systems relating to radiological characterization of environments are disclosed. Multi-detector probes with a plurality of detectors in a common housing may be used to substantially concurrently detect a plurality of different radiation activities and types. Multiple multi-detector probes may be used in a down-hole environment to substantially concurrently detect radioactive activity and contents of a buried waste container. Software may process, analyze, and integrate the data from the different multi-detector probes and the different detector types therein to provide source location and integrated analysis as to the source types and activity in the measured environment. Further, the integrated data may be used to compensate for differential density effects and the effects of radiation shielding materials within the volume being measured.

  2. Measuring element for the detection and determination of radiation doses of gamma radiation and neutrons

    International Nuclear Information System (INIS)

    Jahn, W.; Piesch, E.

    1975-01-01

    A measuring element detects and proves both gamma and neutron radiation. The element includes a photoluminescent material which stores gamma radiation and particles of arsenic and phosphorus embedded in the photoluminescent material for detecting neutron radiation. (U.S.)

  3. SEGMENTATION OF ENVIRONMENTAL TIME LAPSE IMAGE SEQUENCES FOR THE DETERMINATION OF SHORE LINES CAPTURED BY HAND-HELD SMARTPHONE CAMERAS

    Directory of Open Access Journals (Sweden)

    M. Kröhnert

    2017-09-01

    Full Text Available The relevance of globally environmental issues gains importance since the last years with still rising trends. Especially disastrous floods may cause in serious damage within very short times. Although conventional gauging stations provide reliable information about prevailing water levels, they are highly cost-intensive and thus just sparsely installed. Smartphones with inbuilt cameras, powerful processing units and low-cost positioning systems seem to be very suitable wide-spread measurement devices that could be used for geo-crowdsourcing purposes. Thus, we aim for the development of a versatile mobile water level measurement system to establish a densified hydrological network of water levels with high spatial and temporal resolution. This paper addresses a key issue of the entire system: the detection of running water shore lines in smartphone images. Flowing water never appears equally in close-range images even if the extrinsics remain unchanged. Its non-rigid behavior impedes the use of good practices for image segmentation as a prerequisite for water line detection. Consequently, we use a hand-held time lapse image sequence instead of a single image that provides the time component to determine a spatio-temporal texture image. Using a region growing concept, the texture is analyzed for immutable shore and dynamic water areas. Finally, the prevalent shore line is examined by the resultant shapes. For method validation, various study areas are observed from several distances covering urban and rural flowing waters with different characteristics. Future work provides a transformation of the water line into object space by image-to-geometry intersection.

  4. Segmentation of Environmental Time Lapse Image Sequences for the Determination of Shore Lines Captured by Hand-Held Smartphone Cameras

    Science.gov (United States)

    Kröhnert, M.; Meichsner, R.

    2017-09-01

    The relevance of globally environmental issues gains importance since the last years with still rising trends. Especially disastrous floods may cause in serious damage within very short times. Although conventional gauging stations provide reliable information about prevailing water levels, they are highly cost-intensive and thus just sparsely installed. Smartphones with inbuilt cameras, powerful processing units and low-cost positioning systems seem to be very suitable wide-spread measurement devices that could be used for geo-crowdsourcing purposes. Thus, we aim for the development of a versatile mobile water level measurement system to establish a densified hydrological network of water levels with high spatial and temporal resolution. This paper addresses a key issue of the entire system: the detection of running water shore lines in smartphone images. Flowing water never appears equally in close-range images even if the extrinsics remain unchanged. Its non-rigid behavior impedes the use of good practices for image segmentation as a prerequisite for water line detection. Consequently, we use a hand-held time lapse image sequence instead of a single image that provides the time component to determine a spatio-temporal texture image. Using a region growing concept, the texture is analyzed for immutable shore and dynamic water areas. Finally, the prevalent shore line is examined by the resultant shapes. For method validation, various study areas are observed from several distances covering urban and rural flowing waters with different characteristics. Future work provides a transformation of the water line into object space by image-to-geometry intersection.

  5. Utility of hand-held echocardiography in outpatient pediatric cardiology management.

    Science.gov (United States)

    Riley, Alan; Sable, Craig; Prasad, Aparna; Spurney, Christopher; Harahsheh, Ashraf; Clauss, Sarah; Colyer, Jessica; Gierdalski, Marcin; Johnson, Ashley; Pearson, Gail D; Rosenthal, Joanna

    2014-12-01

    Adult patient series have shown hand-held echocardiography (echo) units (HHE) to be accurate for rapid diagnosis and triage. This is the first study to evaluate the ability of HHE to inform decision making in outpatient pediatric cardiology. New pediatric cardiology patients in outpatient clinics staffed by six pediatric cardiologists (experience 1-17 years) were prospectively enrolled if an echocardiogram (echo) was ordered during their initial visit. After history and physical examination and before a standard echo, the cardiologists performed a bedside HHE examination (GE Vscan 1.7-3.8 MHz), documented findings, and made a clinical decision. Diagnoses and decisions based on HHE were compared with final management after the standard echo. The study enrolled 101 subjects (ages 9 days to 19 years). The cardiologists considered HHE imaging adequate for decision making for 80 of the 101 subjects. For 77 of the 80 subjects with acceptable HHE imaging (68/68 normal and 9/12 abnormal standard echoes), the HHE-based primary diagnoses and decisions agreed with the final management. The sensitivity of HHE was 75 % (95 % confidence interval [CI] 43-94 %) and the positive predictive value 100 % (95 % CI 66-100 %) for pediatric heart disease. The agreement between standard echocardiography and HHE imaging was substantial (κ = 0.82). Excluding one of the least experienced cardiologists, HHE provided the basis for correct cardiac diagnoses and management for all the subjects with acceptable HHE imaging (58/58 normal and 9/9 abnormal echoes). In outpatient pediatric cardiology, HHE has potential as a tool to complement physical examination. Further investigation is needed to evaluate how value improves with clinical experience.

  6. Multiwavelength Observations of the Blazar BL Lacertae: A New Fast TeV Gamma-Ray Flare

    Science.gov (United States)

    Abeysekara, A. U.; Benbow, W.; Bird, R.; Brantseg, T.; Brose, R.; Buchovecky, M.; Buckley, J. H.; Bugaev, V.; Connolly, M. P.; Cui, W.; Daniel, M. K.; Falcone, A.; Feng, Q.; Finley, J. P.; Fortson, L.; Furniss, A.; Gillanders, G. H.; Gunawardhana, I.; Hütten, M.; Hanna, D.; Hervet, O.; Holder, J.; Hughes, G.; Humensky, T. B.; Johnson, C. A.; Kaaret, P.; Kar, P.; Kertzman, M.; Krennrich, F.; Lang, M. J.; Lin, T. T. Y.; McArthur, S.; Moriarty, P.; Mukherjee, R.; O’Brien, S.; Ong, R. A.; Otte, A. N.; Park, N.; Petrashyk, A.; Pohl, M.; Pueschel, E.; Quinn, J.; Ragan, K.; Reynolds, P. T.; Richards, G. T.; Roache, E.; Rulten, C.; Sadeh, I.; Santander, M.; Sembroski, G. H.; Shahinyan, K.; Wakely, S. P.; Weinstein, A.; Wells, R. M.; Wilcox, P.; Williams, D. A.; Zitzer, B.; The VERITAS Collaboration; Jorstad, S. G.; Marscher, A. P.; Lister, M. L.; Kovalev, Y. Y.; Pushkarev, A. B.; Savolainen, T.; Agudo, I.; Molina, S. N.; Gómez, J. L.; Larionov, V. M.; Borman, G. A.; Mokrushina, A. A.; Tornikoski, M.; Lähteenmäki, A.; Chamani, W.; Enestam, S.; Kiehlmann, S.; Hovatta, T.; Smith, P. S.; Pontrelli, P.

    2018-04-01

    Combined with measurements made by very-long-baseline interferometry, the observations of fast TeV gamma-ray flares probe the structure and emission mechanism of blazar jets. However, only a handful of such flares have been detected to date, and only within the last few years have these flares been observed from lower-frequency-peaked BL Lac objects and flat-spectrum radio quasars. We report on a fast TeV gamma-ray flare from the blazar BL Lacertae observed by the Very Energetic Radiation Imaging Telescope Array System (VERITAS). with a rise time of ∼2.3 hr and a decay time of ∼36 min. The peak flux above 200 GeV is (4.2 ± 0.6) × 10‑6 photon m‑2 s‑1 measured with a 4-minute-binned light curve, corresponding to ∼180% of the flux that is observed from the Crab Nebula above the same energy threshold. Variability contemporaneous with the TeV gamma-ray flare was observed in GeV gamma-ray, X-ray, and optical flux, as well as in optical and radio polarization. Additionally, a possible moving emission feature with superluminal apparent velocity was identified in Very Long Baseline Array observations at 43 GHz, potentially passing the radio core of the jet around the time of the gamma-ray flare. We discuss the constraints on the size, Lorentz factor, and location of the emitting region of the flare, and the interpretations with several theoretical models that invoke relativistic plasma passing stationary shocks.

  7. Ras p21 and other Gn proteins are detected in mammalian cell lines by [gamma-35S]GTP gamma S binding

    International Nuclear Information System (INIS)

    Comerford, J.G.; Gibson, J.R.; Dawson, A.P.; Gibson, I.

    1989-01-01

    The presence of guanine nucleotide binding proteins in mouse and human cell lines was investigated using [gamma- 35 S]GTP gamma S and [gamma-32P]GTP. Cell lysate polypeptides were separated by sodium dodecyl sulphate polyacrylamide gel electrophoresis and transferred to nitrocellulose. Incubation of the nitrocellulose blots with [gamma- 35 S]GTP gamma S identified 9 distinct GTP-binding polypeptides in all lysates. One of these is the ras oncogene product, p21, as demonstrated by subsequent immunochemical staining of the nitrocellulose blots. We have shown that this procedure provides a sensitive method for detection of p21 in culture cell lines

  8. Probing the Cosmic Gamma-Ray Burst Rate with Trigger Simulations of the Swift Burst Alert Telescope

    Science.gov (United States)

    Lien, Amy; Sakamoto, Takanori; Gehrels, Neil; Palmer, David M.; Barthelmy, Scott D.; Graziani, Carlo; Cannizzo, John K.

    2013-01-01

    The gamma-ray burst (GRB) rate is essential for revealing the connection between GRBs, supernovae and stellar evolution. Additionally, the GRB rate at high redshift provides a strong probe of star formation history in the early universe. While hundreds of GRBs are observed by Swift, it remains difficult to determine the intrinsic GRB rate due to the complex trigger algorithm of Swift. Current studies of the GRB rate usually approximate the Swift trigger algorithm by a single detection threshold. However, unlike the previously own GRB instruments, Swift has over 500 trigger criteria based on photon count rate and additional image threshold for localization. To investigate possible systematic biases and explore the intrinsic GRB properties, we develop a program that is capable of simulating all the rate trigger criteria and mimicking the image threshold. Our simulations show that adopting the complex trigger algorithm of Swift increases the detection rate of dim bursts. As a result, our simulations suggest bursts need to be dimmer than previously expected to avoid over-producing the number of detections and to match with Swift observations. Moreover, our results indicate that these dim bursts are more likely to be high redshift events than low-luminosity GRBs. This would imply an even higher cosmic GRB rate at large redshifts than previous expectations based on star-formation rate measurements, unless other factors, such as the luminosity evolution, are taken into account. The GRB rate from our best result gives a total number of 4568 +825 -1429 GRBs per year that are beamed toward us in the whole universe.

  9. Possibility of observing high energy neutrinos from gamma bursts, with the Antanares telescope, feasibility study; Possibilite d'observation, par le telescope antares, de neutrinos de haute energie associes aux sursauts gamma et validation des techniques de detection a l'aide d'un prototype

    Energy Technology Data Exchange (ETDEWEB)

    Kouchner, A

    2001-04-01

    The European Antares collaboration intends to build a deep-sea neutrino telescope with a detection surface of about 1/10 km{sup 2} in the Mediterranean sea. The universe is transparent to neutrinos, so their study provides a unique means of improving our knowledge of the nature and origin of cosmic rays and their emission from the most powerful astrophysical sources in the cosmos. Neutrinos also offer the possibility of opening a new energy window (E>TeV) for observation of the universe. The first part of the thesis is dedicated to a study of the possibility of using the future telescope to look for correlations between gamma-ray bursts and high-energy neutrinos. It is based, on one hand, on the predictions of neutrino fluxes from gamma-ray bursts in the framework of the theoretical model of 'fireballs', and, on the other hand, on the temporal properties of the gamma-ray bursts in the 4. BATSE catalogue. The second part of the thesis presents the results obtained with a prototype detector line deployed, at the end of 1999, some forty km south-west off Marseilles. The objective was to operate a complete apparatus, similar to the future detector lines, from the shore, and under realistic conditions. Data from 7 photomultiplier tubes disposed along the detector line were transmitted through 37 km of optical fiber to the shore, where they were used to reconstruct tracks due to atmospheric muons, thus validating the detection principles and methods. (author)

  10. Probing the Extragalactic Cosmic-Ray Origin with Gamma-Ray and Neutrino Backgrounds

    Energy Technology Data Exchange (ETDEWEB)

    Globus, Noemie; Piran, Tsvi [Racah Institute of Physics, The Hebrew University, 91904 Jerusalem (Israel); Allard, Denis; Parizot, Etienne [Laboratoire Astroparticule et Cosmologie, Université Paris Diderot/CNRS, 10 rue A. Domon et L. Duquet, F-75205 Paris Cedex 13 (France)

    2017-04-20

    GeV–TeV gamma-rays and PeV–EeV neutrino backgrounds provide a unique window on the nature of the ultra-high-energy cosmic rays (UHECRs). We discuss the implications of the recent Fermi -LAT data regarding the extragalactic gamma-ray background and related estimates of the contribution of point sources as well as IceCube neutrino data on the origin of the UHECRs. We calculate the diffuse flux of cosmogenic γ -rays and neutrinos produced by the UHECRs and derive constraints on the possible cosmological evolution of UHECR sources. In particular, we show that the mixed-composition scenario considered in Globus et al., which is in agreement with both (i) Auger measurements of the energy spectrum and composition up to the highest energies and (ii) the ankle-like feature in the light component detected by KASCADE-Grande, is compatible with both the Fermi -LAT measurements and with current IceCube limits. We also discuss the possibility for future experiments to detect associated cosmogenic neutrinos and further constrain the UHECR models, including possible subdominant UHECR proton sources.

  11. Calculation of induced current densities and specific absorption rates (SAR) for pregnant women exposed to hand-held metal detectors

    International Nuclear Information System (INIS)

    Kainz, Wolfgang; Chan, Dulciana D; Casamento, Jon P; Bassen, Howard I

    2003-01-01

    The finite difference time domain (FDTD) method in combination with a well established frequency scaling method was used to calculate the internal fields and current densities induced in a simple model of a pregnant woman and her foetus, when exposed to hand-held metal detectors. The pregnant woman and foetus were modelled using a simple semi-heterogeneous model in 10 mm resolution, consisting of three different types of tissue. The model is based on the scanned shape of a pregnant woman in the 34th gestational week. Nine different representative models of hand-held metal detectors operating in the frequency range from 8 kHz to 2 MHz were evaluated. The metal detectors were placed directly on the abdomen of the computational model with a spacing of 1 cm. Both the induced current density and the specific absorption rate (SAR) are well below the recommended limits for exposure of the general public published in the ICNIRP Guidelines and the IEEE C95.1 Standard. The highest current density is 8.3 mA m -2 and the highest SAR is 26.5 μW kg -1 . Compared to the limits for the induced current density recommended in the ICNIRP Guidelines, a minimum safety factor of 3 exists. Compared to the IEEE C95.1 Standard, a safety factor of 60,000 for the specific absorption rate was found. Based on the very low specific absorption rate and an induced current density below the recommended exposure limits, significant temperature rise or nerve stimulation in the pregnant woman or in the foetus can be excluded

  12. Detection of sentinel nodes with radiopharmaceuticals

    International Nuclear Information System (INIS)

    Yokoyama, Kunihiko; Michigishi, Takatoshi; Kinuya, Seigo; Konishi, Shota; Nakajima, Kenichi; Tonami, Norihisa

    2000-01-01

    Sentinel lymph nodes have been found to be an indicator of lymph node metastasis in breast cancer. In Japan, the theory and concept of sentinel lymph nodes in breast cancer have begun to be applied to carcinomas of the digestive system. Based on clinical experience in the detection of sentinel lymph nodes with radiopharmaceuticals, differences and similarities between the radiopharmaceuticals, methods, and techniques used to detect sentinel lymph nodes have been assessed in relation to breast cancer and carcinomas of the digestive system (including carcinomas of the esophagus and large intestine). The greatest difference between the methods used for breast and digestive cancers is the site of administration of the radiopharmaceutical. In breast cancer, the radiopharmaceutical is administered into a superficial organ (i.e., the mammary gland), whereas in carcinomas of the digestive system, it is administered into a deep organ (i.e., digestive tract). Another obvious difference is in lymph flow, i.e., the flow of the mammary glands is subcutaneous whereas lymph flow in the digestive tract is submucosal. Two radionuclide diagnostic methods are available to detect sentinel lymph nodes: sentinel lymphoscintigraphy with a gamma camera and a method that involves the use of a gamma probe intraoperatively. Radiopharmaceuticals used to detect sentinel lymph nodes must be smoothly transferred from the site of administration into the lymph, and uptake by the sentinel lymph node must continue for a long time without excessive flowing to lower reaches. The optimal particle size remains a matter of controversy, and no radiopharmaceuticals appropriate for lymphoscintigraphy have ever been approved in Japan. The authors compared the pharmacokinetics of three different radiopharmaceuticals used for sentinel lymphoscintigraphy in breast cancer ( 99m Tc-labeled albumin, 99m Tc-labeled tin colloid, and 99m Tc-labeled phytic acid) and founded that the detection rate was lowest with

  13. The added value of a portable gamma camera for intraoperative detection of sentinel lymph node in squamous cell carcinoma of the oral cavity: A case report.

    Science.gov (United States)

    Mayoral, M; Paredes, P; Sieira, R; Vidal-Sicart, S; Marti, C; Pons, F

    2014-01-01

    The use of sentinel lymph node biopsy in squamous cell carcinoma of the oral cavity is still subject to debate although some studies have reported its feasibility. The main reason for this debate is probably due to the high false-negative rate for floor-of-mouth tumors per se. We report the case of a 54-year-old man with a T1N0 floor-of-mouth squamous cell carcinoma who underwent the sentinel lymph node procedure. Lymphoscintigraphy and SPECT/CT imaging were performed for lymphatic mapping with a conventional gamma camera. Sentinel lymph nodes were identified at right Ib, left IIa and Ia levels. However, these sentinel lymph nodes were difficult to detect intraoperatively with a gamma probe owing to the activity originating from the injection site. The use of a portable gamma camera made it possible to localize and excise all the sentinel lymph nodes. This case demonstrates the usefulness of this tool to improve sentinel lymph node detecting in floor-of-mouth tumors, especially those close to the injection area. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  14. Decreasing of the detection limit for gamma-ray Spectrometry with the influence of sample treatment

    International Nuclear Information System (INIS)

    Karami, M.; Sadighzadeh, A.; Asgharizadeh, F.; Sardari, D.; Tavassoli, A.; Arbabi, A.; Hochaghani, O.

    2009-01-01

    Full text: In this study the ash method has been applied for environmental sample treatment in order to decrease of the detection limit in gamma-ray spectrometry for low level radioactivity measurements. Detection limit in gamma ray spectrometry is the smallest expectation value of the net counting rate that can be detected on given probabilities. The environmental test samples have been changed into ash using a suitable oven. The heating were made under controlled temperature to avoid the escape of some radionuclides such as radiocaesium. The ash samples were measured by high resolution gamma-ray spectrometry system. (author)

  15. Angular resolution study of a combined gamma-neutron coded aperture imager for standoff detection

    International Nuclear Information System (INIS)

    Ayaz-Maierhafer, Birsen; Hayward, Jason P.; Ziock, Klaus P.; Blackston, Matthew A.; Fabris, Lorenzo

    2013-01-01

    Nuclear threat source observables at standoff distances of tens of meters from mCi class sources include both gamma-rays and neutrons. This work uses simulations to investigate the effects of the angular resolution of a mobile gamma-ray and neutron coded aperture imaging system upon orphan source detection significance and specificity. The design requires maintaining high sensitivity and specificity while keeping the system size as compact as possible to reduce weight, footprint, and cost. A mixture of inorganic and organic scintillators was considered in the detector plane for high sensitivity to both gamma-rays and fast neutrons. For gamma-rays (100 to 2500 keV) and fission spectrum neutrons, angular resolutions of 1–9° and radiation angles of incidence appropriate for mobile search were evaluated. Detection significance for gamma-rays considers those events that contribute to the photopeak of the image pixel corresponding the orphan source location. For detection of fission spectrum neutrons, energy depositions above a set pulse shape discrimination threshold were tallied. The results show that the expected detection significance for the system at an angular resolution of 1° is significantly lower compared to its detection significance an angular resolution of ∼3–4°. An angular resolution of ∼3–4° is recommended both for better detection significance and improved false alarm rate, considering that finer angular resolution does not result in improved background rejection when the coded aperture method is used. Instead, over-pixelating the search space may result in an unacceptably high false alarm rate

  16. Rapid detection of Listeria monocytogenes in foods, by a combination of PCR and DNA probe.

    Science.gov (United States)

    Ingianni, A; Floris, M; Palomba, P; Madeddu, M A; Quartuccio, M; Pompei, R

    2001-10-01

    Listeria monocytogenes is a frequent contaminant of water and foods. Its rapid detection is needed before some foods can be prepared for marketing. In this work L. monocytogenes has been searched for in foods, by a combination of polymerase chain reaction (PCR) and a DNA probe. Both PCR and the probe were prepared for recognizing a specific region of the internalin gene, which is responsible for the production of one of the most important pathogenic factors of Listeria. The combined use of PCR and the DNA probe was used for the detection of L. monocytogenes in over 180 environmental and food samples. Several detection methods were compared in this study, namely conventional culture methods; direct PCR; PCR after an enrichment step; a DNA probe alone; a DNA probe after enrichment and another commercially available gene-probe. Finally PCR and the DNA probe were used in series on all the samples collected. When the DNA probe was associated with the PCR, specific and accurate detection of listeria in the samples could be obtained in about a working-day. The present molecular method showed some advantages in terms of rapidity and specificity in comparison to the other aforementioned tests. In addition, it resulted as being easy to handle, even for non-specialized personnel in small diagnostic microbiology laboratories. Copyright 2001 Academic Press.

  17. Detecting gamma-ray anisotropies from decaying dark matter. Prospects for Fermi LAT

    International Nuclear Information System (INIS)

    Ibarra, Alejandro; Tran, David

    2009-09-01

    Decaying dark matter particles could be indirectly detected as an excess over a simple power law in the energy spectrum of the diffuse extragalactic gamma-ray background. Furthermore, since the Earth is not located at the center of the Galactic dark matter halo, the exotic contribution from dark matter decay to the diffuse gamma-ray flux is expected to be anisotropic, offering a complementary method for the indirect search for decaying dark matter particles. In this paper we discuss in detail the expected dipole-like anisotropies in the dark matter signal, taking also into account the radiation from inverse Compton scattering of electrons and positrons from dark matter decay. A different source for anisotropies in the gamma-ray flux are the dark matter density fluctuations on cosmic scales. We calculate the corresponding angular power spectrum of the gamma-ray flux and comment on observational prospects. Finally, we calculate the expected anisotropies for the decaying dark matter scenarios that can reproduce the electron/positron excesses reported by PAMELA and the Fermi LAT, and we estimate the prospects for detecting the predicted gamma-ray anisotropy in the near future. (orig.)

  18. Into the Wild: Neuroergonomic Differentiation of Hand-Held and Augmented Reality Wearable Displays during Outdoor Navigation with Functional Near Infrared Spectroscopy.

    Science.gov (United States)

    McKendrick, Ryan; Parasuraman, Raja; Murtza, Rabia; Formwalt, Alice; Baccus, Wendy; Paczynski, Martin; Ayaz, Hasan

    2016-01-01

    Highly mobile computing devices promise to improve quality of life, productivity, and performance. Increased situation awareness and reduced mental workload are two potential means by which this can be accomplished. However, it is difficult to measure these concepts in the "wild". We employed ultra-portable battery operated and wireless functional near infrared spectroscopy (fNIRS) to non-invasively measure hemodynamic changes in the brain's Prefrontal cortex (PFC). Measurements were taken during navigation of a college campus with either a hand-held display, or an Augmented reality wearable display (ARWD). Hemodynamic measures were also paired with secondary tasks of visual perception and auditory working memory to provide behavioral assessment of situation awareness and mental workload. Navigating with an augmented reality wearable display produced the least workload during the auditory working memory task, and a trend for improved situation awareness in our measures of prefrontal hemodynamics. The hemodynamics associated with errors were also different between the two devices. Errors with an augmented reality wearable display were associated with increased prefrontal activity and the opposite was observed for the hand-held display. This suggests that the cognitive mechanisms underlying errors between the two devices differ. These findings show fNIRS is a valuable tool for assessing new technology in ecologically valid settings and that ARWDs offer benefits with regards to mental workload while navigating, and potentially superior situation awareness with improved display design.

  19. The hand-hold polarization-sensitive spectral domain optical coherence and its applications

    Science.gov (United States)

    Liu, Hao; Gao, Wanrong

    2017-08-01

    The polarization-sensitive spectral domain optical coherence tomography (PSOCT) has the advantages of being able to measure the polarization properties of samples, such as phase-retardation, diattenuation, depolarization, and optical axis orientation, providing a contrast to identify the diseased area and normal area in tissues in PSOCT images. Conventionally, the sample arm of PSOCT is fixed on the stage where biomedical tissues or models is placed, and the OCT images is acquired by scanning with a galvanometer-based mirror. To be applied in the practical diagnosis, a promising way is to design a hand-held device. To this end, it is required that probe is assembled with a small volume to allow for comprehensively imaging large tissues areas at a microscopic scale, and is available to move on different samples to be acquired quickly with negligible motion artifacts. Meanwhile, the probe should be manufactured wih well stability to avoid system jitter error while it is used to detect the biological tissues in vivo. In this work, a design of a hand-hold fiber-based PSOCT is described. The device is of the size of 10 cm (length) × 8 cm (width) × 6 cm (height). Both the axial resolution and the imaging depth of the system are measured and were approximately 7 μm and 2.5 mm in air, respectively, which are in good agreement with the theoretical predictions. The A-scan rate of the system is 70 kHz. The structure is compact and all the components are fixed on the shell to reduce the motion artifact, resulting in a great stability on measuring the tissues in vivo. The cross sectional images of ex vivo chicken breast, ex vivo pork cartilage and in vivo forearm skin of human wolunteer are presented to demonstrate the capability of the system.

  20. Search for right-handed neutrinos from dark matter annihilation with gamma-rays

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Miguel D.; Queiroz, Farinaldo S.; Yaguna, Carlos E. [Max-Planck-Institut für Kernphysik, Saupfercheckweg 1, 69117 Heidelberg (Germany); Weniger, Christoph, E-mail: miguel.campos@mpi-hd.mpg.de, E-mail: farinaldo.queiroz@mpi-hd.mpg.de, E-mail: carlos.yaguna@uptc.edu.co, E-mail: c.weniger@uva.nl [GRAPPA, Institute of Physics, University of Amsterdam, Science Park 904, 1090 GL Amsterdam (Netherlands)

    2017-07-01

    Several extensions of the Standard Model contain right-handed (sterile) neutrinos in the GeV-TeV mass range. Due to their mixing with the active neutrinos, they may give rise to novel effects in cosmology, neutrino physics, and collider searches. In addition, right-handed neutrinos can also appear as final states from dark matter annihilations, with important implications for dark matter indirect detection searches. In this paper, we use current data from the Fermi Large Area Telescope (6-year observation of dwarf spheroidal galaxies) and H.E.S.S. (10-year observation of the Galactic center) to constrain the annihilation of dark matter into right-handed neutrinos. We consider right-handed neutrino with masses between 10 GeV and 1 TeV, including both two-body and three-body decays, to derive bounds on the dark matter annihilation rate, ( σ v ), as a function of the dark matter mass. Our results show, in particular, that the thermal dark matter annihilation cross section, 3× 10{sup −26} cm{sup 3} s {sup −1} , into right-handed neutrinos is excluded for dark matter masses smaller than 200 GeV.

  1. Search for right-handed neutrinos from dark matter annihilation with gamma-rays

    International Nuclear Information System (INIS)

    Campos, Miguel D.; Queiroz, Farinaldo S.; Yaguna, Carlos E.; Weniger, Christoph

    2017-01-01

    Several extensions of the Standard Model contain right-handed (sterile) neutrinos in the GeV-TeV mass range. Due to their mixing with the active neutrinos, they may give rise to novel effects in cosmology, neutrino physics, and collider searches. In addition, right-handed neutrinos can also appear as final states from dark matter annihilations, with important implications for dark matter indirect detection searches. In this paper, we use current data from the Fermi Large Area Telescope (6-year observation of dwarf spheroidal galaxies) and H.E.S.S. (10-year observation of the Galactic center) to constrain the annihilation of dark matter into right-handed neutrinos. We consider right-handed neutrino with masses between 10 GeV and 1 TeV, including both two-body and three-body decays, to derive bounds on the dark matter annihilation rate, ( σ v ), as a function of the dark matter mass. Our results show, in particular, that the thermal dark matter annihilation cross section, 3× 10 −26 cm 3 s −1 , into right-handed neutrinos is excluded for dark matter masses smaller than 200 GeV.

  2. Multiplex fluorescence melting curve analysis for mutation detection with dual-labeled, self-quenched probes.

    Directory of Open Access Journals (Sweden)

    Qiuying Huang

    2011-04-01

    Full Text Available Probe-based fluorescence melting curve analysis (FMCA is a powerful tool for mutation detection based on melting temperature generated by thermal denaturation of the probe-target hybrid. Nevertheless, the color multiplexing, probe design, and cross-platform compatibility remain to be limited by using existing probe chemistries. We hereby explored two dual-labeled, self-quenched probes, TaqMan and shared-stem molecular beacons, in their ability to conduct FMCA. Both probes could be directly used for FMCA and readily integrated with closed-tube amplicon hybridization under asymmetric PCR conditions. Improved flexibility of FMCA by using these probes was illustrated in three representative applications of FMCA: mutation scanning, mutation identification and mutation genotyping, all of which achieved improved color-multiplexing with easy probe design and versatile probe combination and all were validated with a large number of real clinical samples. The universal cross-platform compatibility of these probes-based FMCA was also demonstrated by a 4-color mutation genotyping assay performed on five different real-time PCR instruments. The dual-labeled, self-quenched probes offered unprecedented combined advantage of enhanced multiplexing, improved flexibility in probe design, and expanded cross-platform compatibility, which would substantially improve FMCA in mutation detection of various applications.

  3. Highly selective detection of glutathione using a NIP/Cu2+ complex fluorescent probe

    International Nuclear Information System (INIS)

    Liang Wenrui; Zhao Zhi; Zhang Yang; Wang Qiusheng; Zhao Xin; Ouyang Jie

    2012-01-01

    A novel fluorescent compound, 4-(trimethyl ammonium chloride)acetamide-2-(1H-naphtho[2,3-d]imidazol-2-yl)phenol (TMACA-NIP), was synthesized and used as a fluorescent probe for detecting glutathione reduced (GSH). The new NIP-based probe exhibited high fluorescence in water, which was quenched during the presence of copper (II) due to the complexation between TMACA-NIP and Cu 2+ . But after adding GSH into the TMACA-NIP and Cu 2+ system, the fluorescence of TMACA-NIP was recovered because the binding force between GSH and Cu 2+ is stronger than that between TMACA-NIP and Cu 2+ , which destroys the equilibrium between NIP and copper (II) ions and releases the fluorescence probe of TMACA-NIP. This three-component competing system of NIP/Cu 2+ /GSH can be used to detect GSH simply and rapidly. - Highlights: ► A novel fluorescence probe was developed to detect GSH that operates in aqueous solution. ► TMACA-NIP was synthesized and employed as “read-out” units of NIP/Cu 2+ /GSH. ► NIP-based probe shows high selectivity over other sulfhydryl compounds.

  4. IMRT QA: Selecting gamma criteria based on error detection sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Steers, Jennifer M. [Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, California 90048 and Physics and Biology in Medicine IDP, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California 90095 (United States); Fraass, Benedick A., E-mail: benedick.fraass@cshs.org [Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, California 90048 (United States)

    2016-04-15

    Purpose: The gamma comparison is widely used to evaluate the agreement between measurements and treatment planning system calculations in patient-specific intensity modulated radiation therapy (IMRT) quality assurance (QA). However, recent publications have raised concerns about the lack of sensitivity when employing commonly used gamma criteria. Understanding the actual sensitivity of a wide range of different gamma criteria may allow the definition of more meaningful gamma criteria and tolerance limits in IMRT QA. We present a method that allows the quantitative determination of gamma criteria sensitivity to induced errors which can be applied to any unique combination of device, delivery technique, and software utilized in a specific clinic. Methods: A total of 21 DMLC IMRT QA measurements (ArcCHECK®, Sun Nuclear) were compared to QA plan calculations with induced errors. Three scenarios were studied: MU errors, multi-leaf collimator (MLC) errors, and the sensitivity of the gamma comparison to changes in penumbra width. Gamma comparisons were performed between measurements and error-induced calculations using a wide range of gamma criteria, resulting in a total of over 20 000 gamma comparisons. Gamma passing rates for each error class and case were graphed against error magnitude to create error curves in order to represent the range of missed errors in routine IMRT QA using 36 different gamma criteria. Results: This study demonstrates that systematic errors and case-specific errors can be detected by the error curve analysis. Depending on the location of the error curve peak (e.g., not centered about zero), 3%/3 mm threshold = 10% at 90% pixels passing may miss errors as large as 15% MU errors and ±1 cm random MLC errors for some cases. As the dose threshold parameter was increased for a given %Diff/distance-to-agreement (DTA) setting, error sensitivity was increased by up to a factor of two for select cases. This increased sensitivity with increasing dose

  5. Early detection of radioactive fall-out by gamma-spectrometry

    DEFF Research Database (Denmark)

    Aage, Helle Karina; Korsbech, Uffe C C; Bargholz, K.

    2003-01-01

    Radioactive fallout should be detected as early as possible. A new and efficient method for detection of low-level irradiation from manmade radioactivity is developed. Radiation abnormalities are detectable down to air kerma rate, of 0.5 to 1.0 nGy h(-1) for Cs-137 and even lower for I-131...... For multi-gamma energy radioactivity the detection level is 2.6-3.5 nGy h(-1). A standard NaI detector and a 512-channel analyser are used together with noise adjusted singular value decomposition (NASVD). Statistical noise is removed and the measured spectra are reproduced using spectral components...... radioactive sources need to be detected....

  6. Highly specific detection of genetic modification events using an enzyme-linked probe hybridization chip.

    Science.gov (United States)

    Zhang, M Z; Zhang, X F; Chen, X M; Chen, X; Wu, S; Xu, L L

    2015-08-10

    The enzyme-linked probe hybridization chip utilizes a method based on ligase-hybridizing probe chip technology, with the principle of using thio-primers for protection against enzyme digestion, and using lambda DNA exonuclease to cut multiple PCR products obtained from the sample being tested into single-strand chains for hybridization. The 5'-end amino-labeled probe was fixed onto the aldehyde chip, and hybridized with the single-stranded PCR product, followed by addition of a fluorescent-modified probe that was then enzymatically linked with the adjacent, substrate-bound probe in order to achieve highly specific, parallel, and high-throughput detection. Specificity and sensitivity testing demonstrated that enzyme-linked probe hybridization technology could be applied to the specific detection of eight genetic modification events at the same time, with a sensitivity reaching 0.1% and the achievement of accurate, efficient, and stable results.

  7. Prompt dipole gamma-ray emission in fusionlike heavy-ion reactions

    CERN Document Server

    Pierroutsakou, D; Di Pietro, M; Mordente, R; Ordine, A; Romoli, M; De Rosa, A; Inglima, G; La Commara, M; Martin, B; Roca, V; Sandoli, M; Trotta, M; Vardaci, E; Ming, R; Rizzo, F; Soramel, F; Stroe, L

    2003-01-01

    The sup 3 sup 2 S+ sup 1 sup 0 sup 0 Mo and sup 3 sup 6 S+ sup 9 sup 6 Mo fusionlike reactions were studied at incident energy of E sub l sub a sub b =298 MeV and 320 MeV, respectively, with the aim of probing the influence of the entrance channel charge asymmetry on the dipole gamma-ray emission. The excitation energy and spin distribution of the compound nucleus created in these reactions were identical, the only difference being associated with the unequal charge asymmetry of the two entrance channels. High-energy gamma-rays were detected in an array of 9 seven-pack BaF sub 2 clusters. Coincidence with fusionlike residues detected in four PPAC ensured the selection of central reaction events. By studying the differential gamma-ray multiplicity associated with the two reactions it was shown that the dipole strength excited in the compound nucleus increases with the entrance channel charge asymmetry. From the linearized spectra, the increase of the GDR gamma-ray intensity was found to be propor to 25% for th...

  8. Detection of SNM by delayed gamma rays from induced fission

    International Nuclear Information System (INIS)

    Rennhofer, H.; Crochemore, J.-M.; Roesgen, E.; Pedersen, B.

    2011-01-01

    The Pulsed Neutron Interrogation Test Assembly (PUNITA) is an experimental device for research in NDA methods and field applicable instrumentation for nuclear safeguards and security applications. PUNITA incorporates a standard 14-MeV (D-T) pulsed neutron generator inside a large graphite mantle. The generator target is surrounded by a thick tungsten filter with the purpose to increase the neutron output and to tailor the neutron energy spectrum. In this configuration a sample may be exposed to a relatively high average thermal neutron flux of about (2.2±0.1)x10 3 s -1 cm -2 at only 10% of the maximum target neutron emission. The sample cavity is large enough to allow variation of the experimental setup including the fissile sample, neutron and gamma detectors, and shielding materials. The response from SNM samples of different fissile material content was investigated with various field-applicable scintillation gamma detectors such as the 3x2 in. LaBr 3 detector. Shielding in the form of tungsten and cadmium was applied to the detector to improve the signal to background ratio. Gamma and neutron shields surrounding the samples were also tested for the purpose of simulating clandestine conduct. The energy spectra of delayed gamma rays were recorded in the range 100 keV-9 MeV. In addition time spectra of delayed gamma rays in the range 3.3-8 MeV were recorded in the time period of 10 ms-120 s after the 14-MeV neutron burst. The goal of the experiment was to optimize the sample/detector configuration including the energy range and time period for SNM detection. The results show, for example, that a 170 g sample of depleted uranium can be detected with the given setup in less than 3 min of investigation. Samples of higher enrichment or higher mass are detected in much shorter time.

  9. Drift from the Use of Hand-Held Knapsack Pesticide Sprayers in Boyacá (Colombian Andes).

    Science.gov (United States)

    García-Santos, Glenda; Feola, Giuseppe; Nuyttens, David; Diaz, Jaime

    2016-05-25

    Offsite pesticide losses in tropical mountainous regions have been little studied. One example is measuring pesticide drift soil deposition, which can support pesticide risk assessment for surface water, soil, bystanders, and off-target plants and fauna. This is considered a serious gap, given the evidence of pesticide-related poisoning in those regions. Empirical data of drift deposition of a pesticide surrogate, Uranine tracer, within one of the highest potato-producing regions in Colombia, characterized by small plots and mountain orography, is presented. High drift values encountered in this study reflect the actual spray conditions using hand-held knapsack sprayers. Comparison between measured and predicted drift values using three existing empirical equations showed important underestimation. However, after their optimization based on measured drift information, the equations showed a strong predictive power for this study area and the study conditions. The most suitable curve to assess mean relative drift was the IMAG calculator after optimization.

  10. 3D Scan of Ornamental Column (huabiao Using Terrestrial LiDAR and Hand-held Imager

    Directory of Open Access Journals (Sweden)

    W. Zhang

    2015-08-01

    Full Text Available In ancient China, Huabiao was a type of ornamental column used to decorate important buildings. We carried out 3D scan of a Huabiao located in Peking University, China. This Huabiao was built no later than 1742. It is carved by white marble, 8 meters in height. Clouds and various postures of dragons are carved on its body. Two instruments were used to acquire the point cloud of this Huabiao, a terrestrial LiDAR (Riegl VZ-1000 and a hand-held imager (Mantis Vision F5. In this paper, the details of the experiment were described, including the differences between these two instruments, such as working principle, spatial resolution, accuracy, instrument dimension and working flow. The point clouds obtained respectively by these two instruments were compared, and the registered point cloud of Huabiao was also presented. These should be of interest and helpful for the research communities of archaeology and heritage.

  11. Hand-Eye LRF-Based Iterative Plane Detection Method for Autonomous Robotic Welding

    Directory of Open Access Journals (Sweden)

    Sungmin Lee

    2015-12-01

    Full Text Available This paper proposes a hand-eye LRF-based (laser range finder welding plane-detection method for autonomous robotic welding in the field of shipbuilding. The hand-eye LRF system consists of a 6 DOF manipulator and an LRF attached to the wrist of the manipulator. The welding plane is detected by the LRF with only the wrist's rotation to minimize a mechanical error caused by the manipulator's motion. A position on the plane is determined as an average position of the detected points on the plane, and a normal vector to the plane is determined by applying PCA (principal component analysis to the detected points. In this case, the accuracy of the detected plane is analysed by simulations with respect to the wrist's angle interval and the plane angle. As a result of the analysis, an iterative plane-detection method with the manipulator's alignment motion is proposed to improve the performance of plane detection. For verifying the feasibility and effectiveness of the proposed plane-detection method, experiments are carried out with a prototype of the hand-eye LRF-based system, which consists of a 1 DOF wrist's joint, an LRF system and a rotatable plane. In addition, the experimental results of the PCA-based plane detection method are compared with those of the two representative plane-detection methods, based on RANSAC (RANdom SAmple Consensus and the 3D Hough transform in both accuracy and computation time's points of view.

  12. Minimum detection limit and spatial resolution of thin-sample field-emission electron probe microanalysis

    International Nuclear Information System (INIS)

    Kubo, Yugo; Hamada, Kotaro; Urano, Akira

    2013-01-01

    The minimum detection limit and spatial resolution for a thinned semiconductor sample were determined by electron probe microanalysis (EPMA) using a Schottky field emission (FE) electron gun and wavelength dispersive X-ray spectrometry. Comparison of the FE-EPMA results with those obtained using energy dispersive X-ray spectrometry in conjunction with scanning transmission electron microscopy, confirmed that FE-EPMA is largely superior in terms of detection sensitivity. Thin-sample FE-EPMA is demonstrated as a very effective method for high resolution, high sensitivity analysis in a laboratory environment because a high probe current and high signal-to-noise ratio can be achieved. - Highlights: • Minimum detection limit and spatial resolution determined for FE-EPMA. • Detection sensitivity of FE-EPMA greatly superior to that of STEM-EDX. • Minimum detection limit and spatial resolution controllable by probe current

  13. Gamma detection: an unusual application for surface barrier detectors

    Energy Technology Data Exchange (ETDEWEB)

    Fichtenbaum de Iacub, S; Matatagui, E

    1983-02-01

    The silicon surface barrier detectors (SBD), may be ideal devices to be used in dose indicators for the monitoring of gamma radiations; the SBD working as a cavity sensor. The measurement consists in counting the number of pulses that exceeds a certain level of discrimination, this number being proportional to the absorbed dose. The spectral distribution of the pulses gives an idea of the existing photon field's energy. Characteristic spectra obtained with different gamma and X-ray sources are described and analyzed, and tests are carried out by using different sensitive volumes of the detector in order to determine significant parameters for a gamma-monitor system. The results from the measurements indicate: a) high sensitivity of the system with SBD (high density of material); b) low background: enviromental backgrounds are reliably registered (approx. 10 R/h); c) minimum detectable energies of the order of 60 keV; d) possibility to determine high exposure rates (approx. 100 R/h); e) for emitters of low Z, the result is approximately independent from the gamma energy. These results suggest the possibility of constructing fixed and portable systems, appropriate for gamma monitoring, which utilize SBD as sensors; these devices are adequate for working at enviroment temperatures, being compact, reliable, with low polarization voltages, and of relatively low cost.

  14. Gamma-ray bursts and their use as cosmic probes

    Science.gov (United States)

    2017-01-01

    Since the launch of the highly successful and ongoing Swift mission, the field of gamma-ray bursts (GRBs) has undergone a revolution. The arcsecond GRB localizations available within just a few minutes of the GRB alert has signified the continual sampling of the GRB evolution through the prompt to afterglow phases revealing unexpected flaring and plateau phases, the first detection of a kilonova coincident with a short GRB, and the identification of samples of low-luminosity, ultra-long and highly dust-extinguished GRBs. The increased numbers of GRB afterglows, GRB-supernova detections, redshifts and host galaxy associations has greatly improved our understanding of what produces and powers these immense, cosmological explosions. Nevertheless, more high-quality data often also reveal greater complexity. In this review, I summarize some of the milestones made in GRB research during the Swift era, and how previous widely accepted theoretical models have had to adapt to accommodate the new wealth of observational data. PMID:28791158

  15. Detection of NASBA amplified bacterial tmRNA molecules on SLICSel designed microarray probes

    Directory of Open Access Journals (Sweden)

    Toome Kadri

    2011-02-01

    Full Text Available Abstract Background We present a comprehensive technological solution for bacterial diagnostics using tmRNA as a marker molecule. A robust probe design algorithm for microbial detection microarray is implemented. The probes were evaluated for specificity and, combined with NASBA (Nucleic Acid Sequence Based Amplification amplification, for sensitivity. Results We developed a new web-based program SLICSel for the design of hybridization probes, based on nearest-neighbor thermodynamic modeling. A SLICSel minimum binding energy difference criterion of 4 kcal/mol was sufficient to design of Streptococcus pneumoniae tmRNA specific microarray probes. With lower binding energy difference criteria, additional hybridization specificity tests on the microarray were needed to eliminate non-specific probes. Using SLICSel designed microarray probes and NASBA we were able to detect S. pneumoniae tmRNA from a series of total RNA dilutions equivalent to the RNA content of 0.1-10 CFU. Conclusions The described technological solution and both its separate components SLICSel and NASBA-microarray technology independently are applicative for many different areas of microbial diagnostics.

  16. Detection of NASBA amplified bacterial tmRNA molecules on SLICSel designed microarray probes

    LENUS (Irish Health Repository)

    Scheler, Ott

    2011-02-28

    Abstract Background We present a comprehensive technological solution for bacterial diagnostics using tmRNA as a marker molecule. A robust probe design algorithm for microbial detection microarray is implemented. The probes were evaluated for specificity and, combined with NASBA (Nucleic Acid Sequence Based Amplification) amplification, for sensitivity. Results We developed a new web-based program SLICSel for the design of hybridization probes, based on nearest-neighbor thermodynamic modeling. A SLICSel minimum binding energy difference criterion of 4 kcal\\/mol was sufficient to design of Streptococcus pneumoniae tmRNA specific microarray probes. With lower binding energy difference criteria, additional hybridization specificity tests on the microarray were needed to eliminate non-specific probes. Using SLICSel designed microarray probes and NASBA we were able to detect S. pneumoniae tmRNA from a series of total RNA dilutions equivalent to the RNA content of 0.1-10 CFU. Conclusions The described technological solution and both its separate components SLICSel and NASBA-microarray technology independently are applicative for many different areas of microbial diagnostics.

  17. Glass fiber sensors for detecting special nuclear materials at portal and monitor stations

    International Nuclear Information System (INIS)

    Hull, C.D.; Seymour, R.; Crawford, T.; Bliss, M.; Craig, R.A.

    2001-01-01

    Nuclear Safeguards and Security Systems LLC (NucSafe) participated in the Illicit Trafficking Radiation Assessment Program (ITRAP) recently conducted by the Austrian Research Center, Seibersdorf (ARCS) for IAEA, INTERPOL, and the World Customs Organization (IAEA, in press). This presentation reviews ITRAP test results of NucSafe instrumentation. NucSafe produces stationary, mobile, and hand-held systems that use neutron and gamma ray sensors to detect Special Nuclear Materials (SNM). Neutron sensors are comprised of scintillating glass fibers (trade name 'PUMA' for Pu Materials Analysis), which provide several advantages over 3 He and 10 BF 3 tubes. PUMA 6 Li glass fiber sensors offer greater neutron sensitivity and dynamic counting range with significantly less microphonic susceptibility than tubes, while eliminating transport and operational hazards. PUMA sensors also cost less per active area than gas tubes, which is important since rapid neutron detection at passenger, freight, and vehicle portals require large sensor areas to provide the required sensitivity

  18. A dual neutron/gamma source for the Fissmat Inspection for Nuclear Detection (FIND) system.

    Energy Technology Data Exchange (ETDEWEB)

    Doyle, Barney Lee (Sandia National Laboratories, Albuquerque, NM); King, Michael; Rossi, Paolo (Sandia National Laboratories, Albuquerque, NM); McDaniel, Floyd Del (Sandia National Laboratories, Albuquerque, NM); Morse, Daniel Henry; Antolak, Arlyn J.; Provencio, Paula Polyak (Sandia National Laboratories, Albuquerque, NM); Raber, Thomas N.

    2008-12-01

    Shielded special nuclear material (SNM) is very difficult to detect and new technologies are needed to clear alarms and verify the presence of SNM. High-energy photons and neutrons can be used to actively interrogate for heavily shielded SNM, such as highly enriched uranium (HEU), since neutrons can penetrate gamma-ray shielding and gamma-rays can penetrate neutron shielding. Both source particles then induce unique detectable signals from fission. In this LDRD, we explored a new type of interrogation source that uses low-energy proton- or deuteron-induced nuclear reactions to generate high fluxes of mono-energetic gammas or neutrons. Accelerator-based experiments, computational studies, and prototype source tests were performed to obtain a better understanding of (1) the flux requirements, (2) fission-induced signals, background, and interferences, and (3) operational performance of the source. The results of this research led to the development and testing of an axial-type gamma tube source and the design/construction of a high power coaxial-type gamma generator based on the {sup 11}B(p,{gamma}){sup 12}C nuclear reaction.

  19. A γ detecting probe developed for radioguided surgery and its primary using for animal experiment

    International Nuclear Information System (INIS)

    Wei Haipeng, Lin Yingwu; Gong Peirong; Yang Zhirong; Qiu Shi

    2003-01-01

    A new γ detecting probe device was described, which was used in radioguided surgery (RGS) for detecting tumor and its micrometastasis. The concrete scheme for this system was given in this paper and its performance was also evaluate. The animal experimental results showed that the γ detecting probe has excellent location resolution, and its collimator is practical

  20. Improvement of detection of stress corrosion cracks with ultrasonic phased array probes

    International Nuclear Information System (INIS)

    Wustenberg, H.; Mohrle, W.; Wegner, W.; Schenk, G.; Erhard, A.

    1986-01-01

    Probes with linear arrays can be used for the detection of stress corrosion cracks especially if the variability of the sound field is used to change the skewing angle of angle beam probes. The phased array concept can be used to produce a variable skewing angle or a variable angle of incidence depending on the orientation of the linear array on the wedge. This helps to adapt the direction of the ultrasonic beam to probable crack orientations. It has been demonstrated with artificial reflectors as well as with corrosion cracks, that the detection of misoriented cracks can be improved by this approach. The experiences gained during the investigations are encouraging the application of phased array probes for stress corrosion phenomena close to the heat effected zone of welds. Probes with variable skewing angles may find some interesting applications on welds in tubular structures e.g., at off shore constructions and on some difficult geometries within the primary circuit of nuclear power plants

  1. New Fpg probe chemistry for direct detection of recombinase polymerase amplification on lateral flow strips.

    Science.gov (United States)

    Powell, Michael L; Bowler, Frank R; Martinez, Aurore J; Greenwood, Catherine J; Armes, Niall; Piepenburg, Olaf

    2018-02-15

    Rapid, cost-effective and sensitive detection of nucleic acids has the ability to improve upon current practices employed for pathogen detection in diagnosis of infectious disease and food testing. Furthermore, if assay complexity can be reduced, nucleic acid amplification tests could be deployed in resource-limited and home use scenarios. In this study, we developed a novel Fpg (Formamidopyrimidine DNA glycosylase) probe chemistry, which allows lateral flow detection of amplification in undiluted recombinase polymerase amplification (RPA) reactions. The prototype nucleic acid lateral flow chemistry was applied to a human genomic target (rs1207445), Campylobacter jejuni 16S rDNA and two genetic markers of the important food pathogen E. coli O157:H7. All four assays have an analytical sensitivity between 10 and 100 copies DNA per amplification. Furthermore, the assay is performed with fewer hands-on steps than using the current RPA Nfo lateral flow method as dilution of amplicon is not required for lateral flow analysis. Due to the simplicity of the workflow, we believe that the lateral flow chemistry for direct detection could be readily adapted to a cost-effective single-use consumable, ideal for use in non-laboratory settings. Copyright © 2017. Published by Elsevier Inc.

  2. Power supply connection for ionizing radiation detection probes

    International Nuclear Information System (INIS)

    Zajic, J.

    1990-01-01

    One wire of the supply line is connected, through a diode in the forward direction, to the input terminal of the voltage stabilizer, and through the first resistor to the current limiter terminal of the voltage stabilizer, and also directly to the pulse separator terminal. The current limiter terminal of the voltage stabilizer is connected, through the second resistor, to the output terminal of the voltage stabilizer, and through the first capacitor to the voltage stabilizer earthing terminal, the earthing terminal of the pulse separator and through the other wire of the supply line to the earthing terminal of the detection probe. Furthermore, the input terminal of the voltage stabilizer is connected to a parallel combination of the third resistor with the second capacitor, whose other end is connected to the earthing terminal of the voltage stabilizer. The main asset of this connection consists in the high-frequency matching of the supply line being accomplished by a suitable choice of the resistor value without affecting the voltage for the detection probe. (M.D.)

  3. Development of gamma probe for radiation surveys of the bottoms of surface waters

    International Nuclear Information System (INIS)

    Lee, D.R.; Welch, S.J.; St Aubin, M.J.; Dal Bianco, R.

    1992-01-01

    We have developed a practical method for mapping variations in gamma activity and electrical conductivity of submerged sediments. Prototype probes are being constructed and tested. The first prototype was essentially a background survey meter (Jones, 1979) packaged in a 53-cm-long by 5.4-cm-diameter waterproof vehicle. This tubular vehicle was towed by boat in contact with the bottom sediments of lakes and rivers. Originally, this vehicle was designed (and is still frequently used) for locating groundwater and contaminant entry areas in surface waters. By logging geographic position and sediment variables, it has been possible to produce contour maps in areas of interest. Thus it is possible to optimize environmental analysis and avoid the 'hit or miss' approach of traditional bottom-sediment surveys. (author)

  4. A simple hand-held magnet array for efficient and reproducible SABRE hyperpolarisation using manual sample shaking.

    Science.gov (United States)

    Richardson, Peter M; Jackson, Scott; Parrott, Andrew J; Nordon, Alison; Duckett, Simon B; Halse, Meghan E

    2018-07-01

    Signal amplification by reversible exchange (SABRE) is a hyperpolarisation technique that catalytically transfers nuclear polarisation from parahydrogen, the singlet nuclear isomer of H 2 , to a substrate in solution. The SABRE exchange reaction is carried out in a polarisation transfer field (PTF) of tens of gauss before transfer to a stronger magnetic field for nuclear magnetic resonance (NMR) detection. In the simplest implementation, polarisation transfer is achieved by shaking the sample in the stray field of a superconducting NMR magnet. Although convenient, this method suffers from limited reproducibility and cannot be used with NMR spectrometers that do not have appreciable stray fields, such as benchtop instruments. Here, we use a simple hand-held permanent magnet array to provide the necessary PTF during sample shaking. We find that the use of this array provides a 25% increase in SABRE enhancement over the stray field approach, while also providing improved reproducibility. Arrays with a range of PTFs were tested, and the PTF-dependent SABRE enhancements were found to be in excellent agreement with comparable experiments carried out using an automated flow system where an electromagnet is used to generate the PTF. We anticipate that this approach will improve the efficiency and reproducibility of SABRE experiments carried out using manual shaking and will be particularly useful for benchtop NMR, where a suitable stray field is not readily accessible. The ability to construct arrays with a range of PTFs will also enable the rapid optimisation of SABRE enhancement as function of PTF for new substrate and catalyst systems. © 2017 The Authors Magnetic Resonance in Chemistry Published by John Wiley & Sons Ltd.

  5. Hand held control unit for controlling a display screen-oriented computer game, and a display screen-oriented computer game having one or more such control units

    NARCIS (Netherlands)

    2001-01-01

    A hand-held control unit is used to control a display screen-oriented computer game. The unit comprises a housing with a front side, a set of control members lying generally flush with the front side for through actuating thereof controlling actions of in-game display items, and an output for

  6. Measuring probe for a nuclear reactor

    International Nuclear Information System (INIS)

    Overhoff, T.

    1976-01-01

    A coaxial cable is helically wound into two concentric coils, forming the one end of the probe. At the other end of the probe, the inner conductor's ends are wired to the outer conducter's two extremities by a conductor made of a material with low neutron and gamma interaction cross-section. The direct current produced by this self-powered detector is frequency filtered in order to separate the contributions of the neutron induced secondary-electrons from the photo-electrons, and from the thermally excited conduction electrons. Neutron and gamma fluxes, as well as temperature are therefore determined by using a single probe. (RW) [de

  7. Pulsed eddy current differential probe to detect the defects in a stainless steel pipe

    Science.gov (United States)

    Angani, C. S.; Park, D. G.; Kim, C. G.; Leela, P.; Kishore, M.; Cheong, Y. M.

    2011-04-01

    Pulsed eddy current (PEC) is an electromagnetic nondestructive technique widely used to detect and quantify the flaws in conducting materials. In the present study a differential Hall-sensor probe which is used in the PEC system has been fabricated for the detection of defects in stainless steel pipelines. The differential probe has an exciting coil with two Hall-sensors. A stainless steel test sample with electrical discharge machining (EDM) notches under different depths of 1-5 mm was made and the sample was laminated by plastic insulation having uniform thickness to simulate the pipelines in nuclear power plants (NPPs). The driving coil in the probe is excited by a rectangular current pulse and the resultant response, which is the difference of the two Hall-sensors, has been detected as the PEC probe signal. The discriminating time domain features of the detected pulse such as peak value and time to zero are used to interpret the experimental results with the defects in the test sample. A feature extraction technique such as spectral power density has been devised to infer the PEC response.

  8. Reactor gamma spectrometry: status

    International Nuclear Information System (INIS)

    Gold, R.; Kaiser, B.J.

    1979-01-01

    Current work is described for Compton Recoil Gamma-Ray Spectrometry including developments in experimental technique as well as recent reactor spectrometry measurements. The current status of the method is described concerning gamma spectromoetry probe design and response characteristics. Emphasis is given to gamma spectrometry work in US LWR and BR programs. Gamma spectrometry in BR environments are outlined by focussing on start-up plans for the Fast Test Reactor (FTR). Gamma spectrometry results are presented for a LWR pressure vessel mockup in the Poolside Critical Assembly (PCA) at Oak Ridge National Laboratory

  9. Flexible CMOS low-noise amplifiers for beyond-3G wireless hand-held devices

    Science.gov (United States)

    Becerra-Alvarez, Edwin C.; Sandoval-Ibarra, Federico; de la Rosa, José M.

    2009-05-01

    This paper explores the use of reconfigurable Low-Noise Amplifiers (LNAs) for the implementation of CMOS Radio Frequency (RF) front-ends in the next generation of multi-standard wireless transceivers. Main circuit strategies reported so far for multi-standard LNAs are reviewed and a novel flexible LNA intended for Beyond-3G RF hand-held terminals is presented. The proposed LNA circuit consists of a two-stage topology that combines inductive-source degeneration with PMOS-varactor based tuning network and a programmable load to adapt its performance to different standard specifications without penalizing the circuit noise and with a reduced number of inductors as compared to previous reported reconfigurable LNAs. The circuit has been designed in a 90-nm CMOS technology to cope with the requirements of the GSM, WCDMA, Bluetooth and WLAN (IEEE 802.11b-g) standards. Simulation results, including technology and packaging parasitics, demonstrate correct operation of the circuit for all the standards under study, featuring NF13.3dB and IIP3>10.9dBm, over a 1.85GHz-2.4GHz band, with an adaptive power consumption between 17mW and 22mW from a 1-V supply voltage. Preliminary experimental measurements are included, showing a correct reconfiguration operation within the operation band.

  10. OCT-based angiography in real time with hand-held probe

    Science.gov (United States)

    Gelikonov, Grigory V.; Moiseev, Alexander A.; Ksenofontov, Sergey Y.; Terpelov, Dmitry A.; Gelikonov, Valentine M.

    2018-03-01

    This work is dedicated to development of the OCT system capable to visualize blood vessel network for everyday clinical use. Following problems were solved during the development: compensation of specific natural tissue displacements, induced by contact scanning mode and physiological motion of patients (e.g. respiratory and cardiac motions) and on-line visualization of vessel net to provide the feedback for system operator.

  11. Phenylethynylpyrene excimer forming hybridization probes for fluorescence SNP detection

    DEFF Research Database (Denmark)

    Prokhorenko, Igor A.; Astakhova, Irina V.; Momynaliev, Kuvat T.

    2009-01-01

    Excimer formation is a unique feature of some fluorescent dyes (e.g., pyrene) which can be used for probing the proximity of biomolecules. Pyrene excimer fluorescence has previously been used for homogeneous detection of single nucleotide polymorphism (SNP) on DNA. 1-Phenylethynylpyrene (1-1-PEPy...

  12. Gamma detection: an unusual application for surface barrier detectors

    International Nuclear Information System (INIS)

    Fichtenbaum de Iacub, Silvana; Matatagui, Emilio

    1983-01-01

    The silicon surface barrier detectors (SBD), may be ideal devices to be used in dose indicators for the monitoring of gamma radiations; the SBD working as a cavity sensor. The measurement consists in counting the number of pulses that exceeds a certain level of discrimination, this number being proportional to the absorbed dose. The spectral distribution of the pulses gives an idea of the existing photons field's energy. Characteristic spectra obtained with different gamma-and X ray sources are described and analyzed, and tests are carried out by using different sensitive volumes of the detector in order to determine significant parameters for a gamma-monitor system. The results from the measurements indicate: a) high sensitivity of the system with SBD (high density of material); b) low background: enviromental backgrounds are reliably registered (approx. 10μ R/h); c) minimum detectable energies of the order of 60 keV; d) possibility to determine high exposure rates (approx. 100 R/h); e) for emitters of low Z, the result is approximately independent from the gamma energy. These results suggest the possibility of constructing fixed and portable systems, appropriate for gamma monitoring, which utilize SBD as sensors; these devices are adequate for working at enviroment temperatures, being compact, reliable, with low polarization voltages, and of relatively low cost. (M.E.L.) [es

  13. Fluorescence detection of natural RNA using rationally designed "clickable" oligonucleotide probes

    DEFF Research Database (Denmark)

    Okholm, Anders; Kjems, Jørgen; Astakhova, Kira

    2014-01-01

    Herein a reliable approach to the design of effective fluorescent probes for RNA detection is described. The fluorescence signalling of hybridization by internally positioned polyaromatic hydrocarbons and rhodamine dyes was achieved with a low fluorescence background signal, high fluorescence qua...... quantum yields at ambient and elevated temperature, high selectivity and signal specificity of the probes when binding to miR-7 and circRNA targets....

  14. Direct Detection of Potential Pyrethroids in Yangtze River via an Imprinted Multilayer Phosphorescence Probe.

    Science.gov (United States)

    Chen, Li; Lv, Xiaodong; Dai, Jiangdong; Sun, Lin; Huo, Pengwei; Li, Chunxiang; Yan, Yongsheng

    2018-01-01

    A novel tailored multilayer probe for monitoring potential pyrethroids in the Yangtze River was proposed. The room-temperature phosphorescence method was applied to realize a detection strategy that is superior to the fluorescence method. Efficient Mn-doped ZnS quantum dots with uniform size of 4.6 nm were firstly coated with a mesoporous silica to obtain a suitable intermediate transition layer, then an imprinted layer containing bifenthrin specific recognition sites was anchored. Characterizations verified the multilayer structure convincingly and the detection process relied on the electron transfer-induced fluorescence quenching mechanism. Optional detection time and standard detection curve were obtained within a concentration range from 5.0 to 50 μmol L -1 . The stability was verified to be good after 12 replicates. Feasibility of the probe was proved by monitoring water samples from the Zhenjiang reach of the Yangtze River. The probe offers promise for direct bifenthrin detection in unknown environmental water with an accurate and stable phosphorescence analysis strategy.

  15. Development of a compact light weight DELRAD probe and its integration with UAV NETRA for aerial radiation surveillance

    International Nuclear Information System (INIS)

    Prasad, Mahaveer; Yadav, Ashok Kumar; Gupta, D.K.; Bhatnagar, Vivek; Singh, Chiman; Mishrilal

    2018-01-01

    The DEfence Laboratory RAdiation Detector - 'DELRAD' is an indigenously developed Hybrid Micro Circuit Module employing Si PIN diodes for detection of gamma radiation. Using this as a detector, the 'DELRAD Probe' has been designed and developed specifically for the UAV, NETRA for aerial surveillance of the nuclear affected areas. The critical requirement of very light weight radiation sensor as payload (<50gm) for the UAV NETRA is met by designing this Probe weighing approx. 40gm. The sensor is capable of measuring gamma radiation levels from 1mR/h to 1000R/h. The Probe has been tested, calibrated and integrated with the UAV NETRA. In addition to this, the radiation testing during flight of UAV NETRA integrated with DELRAD probe has also been carried out and results have been recorded. The work carried out proves the capability of Defence Laboratory, Jodhpur, (DRDO) in the area of 'Aerial Surveillance of Nuclear Radiation Affected Area' using Unmanned Aerial Vehicles (UAVs)

  16. The RF Probe: providing space situational awareness through broad-spectrum detection and characterization

    Science.gov (United States)

    Zenick, Raymond; Kohlhepp, Kimberly; Partch, Russell

    2004-09-01

    AeroAstro's patented RF Probe is a system designed to address the needs of spacecraft developers and operators interested in measuring and analyzing near-field RF emissions emanating from a nearby spacecraft of interest. The RF Probe consists of an intelligent spectrum analyzer with digital signal processing capabilities combined with a calibrated, wide-bandwidth antenna and RF front end that covers the 50 kHz to 18 GHz spectrum. It is capable of acquiring signal level and signal vector information, classifying signals, assessing the quality of a satellite"s transponders, and characterizing near-field electromagnetic emissions. The RF Probe is intended for either incorporation as part of a suite of spacecraft sensors, or as a stand-alone sensor on spacecraft or other platforms such as Unmanned Aerial Vehicles (UAVs). The RF Probe was initially conceived as a tool to detect and aid in diagnosis of malfunctions in a spacecraft of interest. However, the utility of the RF Probe goes far beyond this initial concept, spanning a wide range of military applications. Most importantly, the RF Probe can provide space situational awareness for critical on-orbit assets by detecting externally induced RF fields, aiding in protection against potentially devastating attacks.

  17. REVEALING TYPE Ia SUPERNOVA PHYSICS WITH COSMIC RATES AND NUCLEAR GAMMA RAYS

    International Nuclear Information System (INIS)

    Horiuchi, Shunsaku; Beacom, John F.

    2010-01-01

    Type Ia supernovae (SNe Ia) remain mysterious despite their central importance in cosmology and their rapidly increasing discovery rate. The progenitors of SNe Ia can be probed by the delay time between progenitor birth and explosion as SNe Ia. The explosions and progenitors of SNe Ia can be probed by MeV nuclear gamma rays emitted in the decays of radioactive nickel and cobalt into iron. We compare the cosmic star formation and SN Ia rates, finding that their different redshift evolution requires a large fraction of SNe Ia to have large delay times. A delay-time distribution of the form t -α with α = 1.0 ± 0.3 provides a good fit, implying that 50% of SNe Ia explode more than ∼1 Gyr after progenitor birth. The extrapolation of the cosmic SN Ia rate to z = 0 agrees with the rate we deduce from catalogs of local SNe Ia. We investigate prospects for gamma-ray telescopes to exploit the facts that escaping gamma rays directly reveal the power source of SNe Ia and uniquely provide tomography of the expanding ejecta. We find large improvements relative to earlier studies by Gehrels et al. in 1987 and Timmes and Woosley in 1997 due to larger and more certain SN Ia rates and advances in gamma-ray detectors. The proposed Advanced Compton Telescope, with a narrow-line sensitivity ∼60 times better than that of current satellites, would, on an annual basis, detect up to ∼100 SNe Ia (3σ) and provide revolutionary model discrimination for SNe Ia within 20 Mpc, with gamma-ray light curves measured with ∼10σ significance daily for ∼100 days. Even more modest improvements in detector sensitivity would open a new and invaluable astronomy with frequent SN Ia gamma-ray detections.

  18. Trace Contraband Detection Field-Test by the South Texas Specialized Crimes and Narcotics Task Force

    Energy Technology Data Exchange (ETDEWEB)

    Hannum, David W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Contraband Detection Dept.; Shannon, Gary W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Contraband Detection Dept.

    2006-04-01

    This report describes the collaboration between the South Texas Specialized Crimes and Narcotics Task Force (STSCNTF) and Sandia National Laboratories (SNL) in a field test that provided prototype hand-held trace detection technology for use in counter-drug operations. The National Institute of Justice (NIJ)/National Law Enforcement and Corrections Technology Center (NLECTC)/Border Research and Technology Center (BRTC) was contacted by STSCNTF for assistance in obtaining cutting-edge technology. The BRTC created a pilot project for Sandia National Laboratories (SNL) and the STSCNTF for the use of SNL’s Hound, a hand-held sample collection and preconcentration system that, when combined with a commercial chemical detector, can be used for the trace detection of illicit drugs and explosives. The STSCNTF operates in an area of high narcotics trafficking where methods of concealment make the detection of narcotics challenging. Sandia National Laboratories’ (SNL) Contraband Detection Department personnel provided the Hound system hardware and operational training. The Hound system combines the GE VaporTracer2, a hand-held commercial chemical detector, with an SNL-developed sample collection and preconcentration system. The South Texas Task force reported a variety of successes, including identification of a major shipment of methamphetamines, the discovery of hidden compartments in vehicles that contained illegal drugs and currency used in drug deals, and the identification of a suspect in a nightclub shooting. The main advantage of the hand-held trace detection unit is its ability to quickly identify the type of chemical (drugs or explosives) without a long lag time for laboratory analysis, which is the most common analysis method for current law enforcement procedures.

  19. Increased detectability of somatic changes in the DNA from human tumours after probing with "synthetic" and "genome-derived" hypervariable multilocus probes

    DEFF Research Database (Denmark)

    Lagoda, P J; Seitz, G; Epplen, J T

    1989-01-01

    intensities were observed. Together the probes 33.15 and (CAC)5/(GTG)5 detected deviating fingerprint patterns in 63% of the colorectal carcinomas investigated. In mammary and stomach carcinomas, only 1/11 and 2/11 tumours, respectively, showed differences with either of the three probes, 33.15, (GACA)4...

  20. A novel method of multiple nucleic acid detection: Real-time RT-PCR coupled with probe-melting curve analysis.

    Science.gov (United States)

    Han, Yang; Hou, Shao-Yang; Ji, Shang-Zhi; Cheng, Juan; Zhang, Meng-Yue; He, Li-Juan; Ye, Xiang-Zhong; Li, Yi-Min; Zhang, Yi-Xuan

    2017-11-15

    A novel method, real-time reverse transcription PCR (real-time RT-PCR) coupled with probe-melting curve analysis, has been established to detect two kinds of samples within one fluorescence channel. Besides a conventional TaqMan probe, this method employs another specially designed melting-probe with a 5' terminus modification which meets the same label with the same fluorescent group. By using an asymmetric PCR method, the melting-probe is able to detect an extra sample in the melting stage effectively while it almost has little influence on the amplification detection. Thus, this method allows the availability of united employment of both amplification stage and melting stage for detecting samples in one reaction. The further demonstration by simultaneous detection of human immunodeficiency virus (HIV) and hepatitis C virus (HCV) in one channel as a model system is presented in this essay. The sensitivity of detection by real-time RT-PCR coupled with probe-melting analysis was proved to be equal to that detected by conventional real-time RT-PCR. Because real-time RT-PCR coupled with probe-melting analysis can double the detection throughputs within one fluorescence channel, it is expected to be a good solution for the problem of low-throughput in current real-time PCR. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. INTEGRAL Detection of the First Prompt Gamma-Ray Signal Coincident with the Gravitational-wave Event GW170817

    DEFF Research Database (Denmark)

    Savchenko, V.; Ferrigno, C.; Kuulkers, E.

    2017-01-01

    We report the INTernational Gamma-ray Astrophysics Laboratory (INTEGRAL) detection of the short gamma-ray burst GRB 170817A (discovered by Fermi-GBM) with a signal-to-noise ratio of 4.6, and, for the first time, its association with the gravitational waves (GWs) from binary neutron star (BNS......) merging event GW170817 detected by the LIGO and Virgo observatories. The significance of association between the gamma-ray burst observed by INTEGRAL and GW170817 is 3.2σ, while the association between the Fermi-GBM and INTEGRAL detections is 4.2σ. GRB 170817A was detected by the SPI-ACS instrument about...

  2. New concepts of fluorescent probes for specific detection of DNA sequences: bis-modified oligonucleotides in excimer and exciplex detection.

    Science.gov (United States)

    Gbaj, A; Bichenkova, Ev; Walsh, L; Savage, He; Sardarian, Ar; Etchells, Ll; Gulati, A; Hawisa, S; Douglas, Kt

    2009-12-01

    The detection of single base mismatches in DNA is important for diagnostics, treatment of genetic diseases, and identification of single nucleotide polymorphisms. Highly sensitive, specific assays are needed to investigate genetic samples from patients. The use of a simple fluorescent nucleoside analogue in detection of DNA sequence and point mutations by hybridisation in solution is described in this study. The 5'-bispyrene and 3'-naphthalene oligonucleotide probes form an exciplex on hybridisation to target in water and the 5'-bispyrene oligonucleotide alone is an adequate probe to determine concentration of target present. It was also indicated that this system has a potential to identify mismatches and insertions. The aim of this work was to investigate experimental structures and conditions that permit strong exciplex emission for nucleic acid detectors, and show how such exciplexes can register the presence of mismatches as required in SNP analysis. This study revealed that the hybridisation of 5'-bispyrenyl fluorophore to a DNA target results in formation of a fluorescent probe with high signal intensity change and specificity for detecting a complementary target in a homogeneous system. Detection of SNP mutations using this split-probe system is a highly specific, simple, and accessible method to meet the rigorous requirements of pharmacogenomic studies. Thus, it is possible for the system to act as SNP detectors and it shows promise for future applications in genetic testing.

  3. Detection and measurement of gamma-ray self-attenuation in plutonium residues

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Foster, L.A.; Estep, R.J.

    1996-01-01

    A new method to correct for self-attenuation in gamma-ray assays of plutonium is presented. The underlying assumptions of the technique are based on a simple but accurate physical model of plutonium residues, particularly pyrochemical salts, in which it is assumed that the plutonium is divided into two portions, each of which can be treated separately from the standpoint of gamma-ray analysis: a portion that is in the form of plutonium metal shot; and a dilute portion that is mixed with the matrix. The performance of the technique is evaluated using assays of plutonium residues by tomographic gamma scanning at the Los Alamos Plutonium Facility. The ability of the method to detect saturation conditions is examined

  4. [A novel TaqMan® MGB probe for specifically detecting Streptococcus mutans].

    Science.gov (United States)

    Zheng, Hui; Lin, Jiu-Xiang; DU, Ning; Chen, Feng

    2013-10-18

    To design a new TaqMan® MGB probe for improving the specificity of Streptococcus mutans's detection. We extracted six DNA samples from different streptococcal strains for PCR reaction. Conventional nested PCR and TaqMan® MGB real-time PCR were applied independently. The first round of nested PCR was carried out with the bacterial universal primers, while a second PCR was conducted by using primers specific for the 16S rRNA gene of Streptococcus mutans. The TaqMan® MGB probe for Streptococcus mutans was designed from sequence analyses, and the primers were the same as nested PCR. Streptococcus mutans DNA with 2.5 mg/L was sequentially diluted at 5-fold intervals to 0.16 μg/L. Standard DNA samples were used to generate standard curves by TaqMan® MGB real-time PCR. In the nested PCR, the primers specific for Streptococcus mutans also detected Streptococcus gordonii with visible band of 282 bp, giving false-positive results. In the TaqMan® MGB real-time PCR reaction, only Streptococcus mutans was detected. The detection limitation of TaqMan® MGB real-time PCR for Streptococcus mutans 16S rRNA gene was 20 μg/L. We designed a new TaqMan® MGB probe, and successfully set up a PCR based method for detecting oral Streptococcus mutans. TaqMan® MGB real-time PCR is a both specific and sensitive bacterial detection method.

  5. Reduction of Compton background from hydrogen in prompt gamma-ray analysis by multiple photon detection

    International Nuclear Information System (INIS)

    Toh, Y.; Oshima, M.; Kimura, A.; Koizumi, M.; Furutaka, K.; Hatsukawa, Y.

    2008-01-01

    Low-energy photons produced by the Compton scattering from hydrogen increase the background in the lower-energy region of the gamma-ray spectrum. This results in an increase in the detection limit for trace elements. In multiple photon detection prompt gamma-ray analysis (MPGA), only those elements that simultaneously emit two or more prompt gamma-rays, which have cascade relation and are emitted within a short interval, can be measured. Therefore, the influence of hydrogen can be reduced. In this study, standard polymer and food samples are measured. The hydrogen background is reduced in MPGA. (author)

  6. Hand-held triangulation laser profilometer with audio output for blind people Profilométre laser à triangulation tenu en main avec sortie sonare pour non-voyants

    Science.gov (United States)

    Farcy, R.; Damaschini, R.

    1998-06-01

    We describe a device currently under industrial development which will give to the blind a means of three-dimensional space perception. It consists of a 350 g hand-held triangulating laser telemeter including electronic parts and batteries, with auditory feedback either inside the apparatus or close to the ear. The microprocessor unit converts in real time the distance measured by the telemeter into a musical note. Scanning the space with an adequate movement of the hand produces musical lines corresponding to the profiles of the environment. We discuss the optical configuration of the system relative to our first year of clinical experimentation.

  7. Discuss the technology for decrease the detection limit of NaI(Tl) gamma spectrometer

    International Nuclear Information System (INIS)

    Guo Xiaobin; Qu Guopu; Liu Zhiying; Wang Hongyan; Wang Lieming

    2011-01-01

    The radioelement species is complex and quantity is few after nuclear explosion, thus it is hard to tell the difference when using the Nal (TI) Gamma spectrometer detection due to several kinds of the peak of nuclide overlapped in the scattering region. So there is a high demand for spectrometer stability, energy resolution, solution spectrum and minimum detective activity. The paper analysed the influenced factors to Nal (TI) Gamma spectrometer and the measures of detection limit decrease by experiments and MCNP simulation, which proposed the methods to reduce background through shielding in order to improve minimum detective activity. The experiment shows that choosing reasonable shielding can reduce the background effectively and improve the spectrometer low level radioactive detect ability. (authors)

  8. Gamma-resonance Contraband Detection using a high current tandem accelerator

    International Nuclear Information System (INIS)

    Milton, B. F.; Beis, J.; Dale, D.; Rogers, J.; Ruegg, R.; Debiak, T.; Kamykowski, E.; Melnychuk, S.; Rathke, J.; Sredniawski, J.

    1999-01-01

    TRIUMF and Northrop Grumman have developed a new system for the detection of concealed explosives and drugs. This Contraband Detection System (CDS) is based on the resonant absorption by 14 N of gammas produced using 13 C(p,γ) 14 N. The chosen reaction uses protons at 1.75 MeV and the gammas have an energy of 9.17 MeV. By measuring both the resonant and the non-resonant absorption using detectors with good spatial resolution, and applying standard tomographic techniques, we are able to produce 3D images of both the nitrogen partial density and the total density. The images together may be utilized with considerable confidence to determine if small amounts of nitrogen based explosives, heroin or cocaine are present in the interrogated containers. Practical Gamma Resonant Absorption (GRA) scanning requires an intense source of protons. However this proton source must also be very stable, have low energy spread, and have good spatial definition. These demands suggested a tandem as the accelerator of choice. We have therefore constructed a 2 MeV H - tandem optimized for high current (10 mA) operation, while minimizing the overall size of the accelerator. This has required several special innovations which will be presented in the paper. We will also present initial commissioning results

  9. Highly accurate determination of relative gamma-ray detection efficiency for Ge detector and its application

    International Nuclear Information System (INIS)

    Miyahara, H.; Mori, C.; Fleming, R.F.; Dewaraja, Y.K.

    1997-01-01

    When quantitative measurements of γ-rays using High-Purity Ge (HPGe) detectors are made for a variety of applications, accurate knowledge of oy-ray detection efficiency is required. The emission rates of γ-rays from sources can be determined quickly in the case that the absolute peak efficiency is calibrated. On the other hand, the relative peak efficiencies can be used for determination of intensity ratios for plural samples and for comparison to the standard source. Thus, both absolute and relative detection efficiencies are important in use of γ-ray detector. The objective of this work is to determine the relative gamma-ray peak detection efficiency for an HPGe detector with the uncertainty approaching 0.1% . We used some nuclides which emit at least two gamma-rays with energies from 700 to 2400 keV for which the relative emission probabilities are known with uncertainties much smaller than 0.1%. The relative peak detection efficiencies were calculated from the measurements of the nuclides, 46 Sc, 48 Sc, 60 Co and 94 Nb, emitting two γ- rays with the emission probabilities of almost unity. It is important that various corrections for the emission probabilities, the cascade summing effect, and the self-absorption are small. A third order polynomial function on both logarithmic scales of energy and efficiency was fitted to the data, and the peak efficiency predicted at certain energy from covariance matrix showed the uncertainty less than 0.5% except for near 700 keV. As an application, the emission probabilities of the 1037.5 and 1212.9 keV γ-rays for 48 Sc were determined using the function of the highly precise relative peak efficiency. Those were 0.9777+0,.00079 and 0.02345+0.00017 for the 1037.5 and 1212.9 keV γ-rays, respectively. The sum of these probabilities is close to unity within the uncertainty which means that the certainties of the results are high and the accuracy has been improved considerably

  10. Detection of high energy gamma radiations with liquid rare gases as scintillators; Detection des rayonnements Gamma de grande energie avec les gaz rares liquides comme scintillateurs

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Phan Xuan

    1965-11-25

    This research thesis reports the study of a sensor based on a liquid scintillator for the detection of high energy (10 to 30 MeV) gamma radiations. The scintillator is a liquefied argon or xenon rare gas. The author first studies the process of energy transfer from the particle to the sensing medium. He addresses the different involved elements and phenomena: electromagnetic radiations (Compton Effect, photoelectric effect, pair production, and total gamma absorption), charged particles (braking radiation, collisions) and application to gamma spectrometry. He describes and discusses the scintillation mechanisms (scintillation of organic and inorganic materials), the general characteristics of scintillators (impurities, converters), and then reports the practical realisation of the sensor. Results are presented and discussed [French] Dans ce travail, nous nous proposons d'etudier une technique. Il s'agit d'un detecteur a scintillateur liquide pour la detection des rayonnements gamma energiques (10 a 30 MeV). Le scintillateur utilise est un gaz rare liquefie argon ou xenon. Nous examinerons d'abord les processus de transfert de l'energie de la particule au milieu detecteur puis les mecanismes de scintillation en general pour pouvoir exploiter au mieux les phenomenes favorables. Nous presenterons ensuite la realisation pratique du detecteur. Ses qualites (et defauts) trouveront leur place dans la fin de ce memoire. Bien qu'a l'heure actuelle, par la methode de Kyropoulos, on puisse faire pousser des gros cristaux d'iodure de sodium, l'utilisation des 'gaz rares' liquefies comme scintillateurs est, grace a la brievete de la scintillation, tres utile lorsqu'on recherche un fort taux de comptage (jusqu'a 10 impulsions par seconde) ou lorsqu'on veut resoudre certains problemes de coincidence. Les cristaux NaI(Tl) de grandes dimensions sont d'un montage facile mais leur manipulation requiert beaucoup de precautions du fait qu'ils supportent tres mal les chocs thermiques

  11. Detection of mixed-range proton pencil beams with a prompt gamma slit camera

    International Nuclear Information System (INIS)

    Priegnitz, M; Helmbrecht, S; Fiedler, F; Janssens, G; Smeets, J; Vander Stappen, F; Perali, I; Sterpin, E

    2016-01-01

    With increasing availability of proton and particle therapy centers for tumor treatment, the need for in vivo range verification methods comes more into the focus. Imaging of prompt gamma rays emitted during the treatment is one of the possibilities currently under investigation. A knife-edge shaped slit camera was recently proposed for this task and measurements proved the feasibility of range deviation detection in homogeneous and inhomogeneous targets. In the present paper, we concentrate on laterally inhomogeneous materials, which lead to range mixing situations when crossed by one pencil beam: different sections of the beam have different ranges. We chose exemplative cases from clinical irradiation and assembled idealized tissue equivalent targets. One-dimensional emission profiles were obtained by measuring the prompt gamma emission with the slit camera. It could be shown that the resulting range deviations can be detected by evaluation of the measured data with a previously developed range deviation detection algorithm. The retrieved value, however, strongly depends on the target composition, and is not necessarily in direct relation to the ranges of both parts of the beam. By combining the range deviation detection with an analysis of the slope of the distal edge of the measured prompt gamma profile, the origin of the detected range deviation, i.e. the mixed range of the beam, is also identified. It could be demonstrated that range mixed prompt gamma profiles exhibit less steep distal slopes than profiles from beams traversing laterally homogeneous material. For future application of the slit camera to patient irradiation with double scattered proton beams, situations similar to the range mixing cases are present and results could possibly apply. (paper)

  12. Highly selective and rapidly responsive fluorescent probe for hydrogen sulfide detection in wine.

    Science.gov (United States)

    Wang, Hao; Wang, Jialin; Yang, Shaoxiang; Tian, Hongyu; Liu, Yongguo; Sun, Baoguo

    2018-08-15

    A new fluorescent probe 6-(2, 4-dinitrophenoxy)-2-naphthonitrile (probe 1) was designed and synthesized for the selective detection of hydrogen sulfide (H 2 S). The addition of H 2 S to a solution of probe 1 resulted in a marked fluorescence turn-on alongside a visual color change from colorless to light yellow. Importantly, this distinct color response indicated that probe 1 could be used as a visual sensor for H 2 S. Moreover, probe 1 was successfully used as a signal tool to determine the H 2 S levels in beer and red wine. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Optimization of plastic scintillator thicknesses for online beta/gamma detection

    Directory of Open Access Journals (Sweden)

    Pourtangestani K.

    2012-04-01

    Full Text Available For efficient beta detection in a mixed beta gamma field, Monte Carlo simulation models have been built to optimize the thickness of a plastic scintillator, used in a whole body monitor. The simulation has been performed using the MCNP/X code for different thicknesses of plastic scintillator from 150 μm to 600 μm. The relationship between the thickness of the scintillator and the efficiency of the detector has been analyzed. For 150 μm thickness, an experimental investigation has been conducted with different beta sources at different positions on the scintillator and the counting efficiency of the unit has been measured. Evaluated data along with experimental ones have been discussed. A thickness of 300 μm to 500 μm has been found to be the optimum thickness for high efficiency beta detection in the presence of low energy gamma-rays.

  14. Perspectives on Gamma-Ray Burst Physics and Cosmology with Next Generation Facilities

    Science.gov (United States)

    Yuan, Weimin; Amati, Lorenzo; Cannizzo, John K.; Cordier, Bertrand; Gehrels, Neil; Ghirlanda, Giancarlo; Götz, Diego; Produit, Nicolas; Qiu, Yulei; Sun, Jianchao; Tanvir, Nial R.; Wei, Jianyan; Zhang, Chen

    2016-12-01

    High-redshift Gamma-Ray Bursts (GRBs) beyond redshift {˜}6 are potentially powerful tools to probe the distant early Universe. Their detections in large numbers and at truly high redshifts call for the next generation of high-energy wide-field instruments with unprecedented sensitivity at least one order of magnitude higher than the ones currently in orbit. On the other hand, follow-up observations of the afterglows of high-redshift GRBs and identification of their host galaxies, which would be difficult for the currently operating telescopes, require new, extremely large facilities of at multi-wavelengths. This chapter describes future experiments that are expected to advance this exciting field, both being currently built and being proposed. The legacy of Swift will be continued by SVOM, which is equipped with a set of space-based multi-wavelength instruments as well as and a ground segment including a wide angle camera and two follow-up telescopes. The established Lobster-eye X-ray focusing optics provides a promising technology for the detection of faint GRBs at very large distances, based on which the THESEUS, Einstein Probe and other mission concepts have been proposed. Follow-up observations and exploration of the reionization era will be enabled by large facilities such as SKA in the radio, the 30 m class telescopes in the optical/near-IR, and the space-borne WFIRST and JWST in the optical/near-IR/mid-IR. In addition, the X-ray and γ-ray polarization experiment POLAR is also introduced.

  15. Optical probe for porosity defect detection on inner diameter surfaces of machined bores

    Science.gov (United States)

    Kulkarni, Ojas P.; Islam, Mohammed N.; Terry, Fred L.

    2010-12-01

    We demonstrate an optical probe for detection of porosity inside spool bores of a transmission valve body with diameters down to 5 mm. The probe consists of a graded-index relay rod that focuses a laser beam spot onto the inner surface of the bore. Detectors, placed in the specular and grazing directions with respect to the incident beam, measure the change in scattered intensity when a surface defect is encountered. Based on the scattering signatures in the two directions, the system can also validate the depth of the defect and distinguish porosity from bump-type defects coming out of the metal surface. The system can detect porosity down to a 50-μm lateral dimension and ~40 μm in depth with >3-dB contrast over the background intensity fluctuations. Porosity detection systems currently use manual inspection techniques on the plant floor, and the demonstrated probe provides a noncontact technique that can help automotive manufacturers meet high-quality standards during production.

  16. Leak detection by vibrational diagnostic methods

    International Nuclear Information System (INIS)

    Siklossy, P.

    1983-01-01

    The possibilities and methods of leak detection due to mechanical failures in nuclear power plants are reviewed on the basis of the literature. Great importance is attributed to vibrational diagnostic methods for their adventageous characteristics which enable them to become final leak detecting methods. The problems of noise analysis, e.g. leak detection by impact sound measurements, probe characteristics, gain problems, probe selection, off-line analysis and correlation functions, types of leak noises etc. are summarized. Leak detection based on noise analysis can be installed additionally to power plants. Its maintenance and testing is simple. On the other hand, it requires special training and measuring methods. (Sz.J.)

  17. Gold nanoparticle-based probes for the colorimetric detection of Mycobacterium avium subspecies paratuberculosis DNA.

    Science.gov (United States)

    Ganareal, Thenor Aristotile Charles S; Balbin, Michelle M; Monserate, Juvy J; Salazar, Joel R; Mingala, Claro N

    2018-02-12

    Gold nanoparticle (AuNP) is considered to be the most stable metal nanoparticle having the ability to be functionalized with biomolecules. Recently, AuNP-based DNA detection methods captured the interest of researchers worldwide. Paratuberculosis or Johne's disease, a chronic gastroenteritis in ruminants caused by Mycobacterium avium subsp. paratuberculosis (MAP), was found to have negative effect in the livestock industry. In this study, AuNP-based probes were evaluated for the specific and sensitive detection of MAP DNA. AuNP-based probe was produced by functionalization of AuNPs with thiol-modified oligonucleotide and was confirmed by Fourier-Transform Infrared (FTIR) spectroscopy. UV-Vis spectroscopy and Scanning Electron Microscopy (SEM) were used to characterize AuNPs. DNA detection was done by hybridization of 10 μL of DNA with 5 μL of probe at 63 °C for 10 min and addition of 3 μL salt solution. The method was specific to MAP with detection limit of 103 ng. UV-Vis and SEM showed dispersion and aggregation of the AuNPs for the positive and negative results, respectively, with no observed particle growth. This study therefore reports an AuNP-based probes which can be used for the specific and sensitive detection of MAP DNA. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Very high-energy gamma rays from gamma-ray bursts.

    Science.gov (United States)

    Chadwick, Paula M

    2007-05-15

    Very high-energy (VHE) gamma-ray astronomy has undergone a transformation in the last few years, with telescopes of unprecedented sensitivity having greatly expanded the source catalogue. Such progress makes the detection of a gamma-ray burst at the highest energies much more likely than previously. This paper describes the facilities currently operating and their chances for detecting gamma-ray bursts, and reviews predictions for VHE gamma-ray emission from gamma-ray bursts. Results to date are summarized.

  19. Alpha detection in pipes using an inverting membrane scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Kendrick, D.T.; Cremer, C.D.; Lowry, W. [Science and Engineering Associates, Inc., Albuquerque, NM (United States)] [and others

    1995-10-01

    Characterization of surface alpha emitting contamination inside enclosed spaces such as piping systems presents an interesting radiological measurement challenge. Detection of these alpha particles from the exterior of the pipe is impossible since the alpha particles are completely absorbed by the pipe wall. Traditional survey techniques, using hand-held instruments, simply can not be used effectively inside pipes. Science and Engineering Associates, Inc. is currently developing an enhancement to its Pipe Explorer{trademark} system that will address this challenge. The Pipe Explorer{trademark} uses a unique sensor deployment method where an inverted tubular membrane is propagated through complex pipe runs via air pressure. The inversion process causes the membrane to fold out against the pipe wall, such that no part of the membrane drags along the pipe wall. This deployment methodology has been successfully demonstrated at several DOE sites to transport specially designed beta and gamma, scintillation detectors into pipes ranging in length up to 250 ft.

  20. New Concepts of Fluorescent Probes for Specific Detection of DNA Sequences: Bis-Modified Oligonucleotides in Excimer and Exciplex Detection

    Directory of Open Access Journals (Sweden)

    Gbaj A

    2009-01-01

    Full Text Available The detection of single base mismatches in DNA is important for diagnostics, treatment of genetic diseases, and identification of single nucleotide polymorphisms. Highly sensitive, specific assays are needed to investigate genetic samples from patients. The use of a simple fluorescent nucleoside analogue in detection of DNA sequence and point mutations by hybridisation in solution is described in this study. The 5’-bispyrene and 3’-naphthalene oligonucleotide probes form an exciplex on hybridisation to target in water and the 5’-bispyrene oligonucleotide alone is an adequate probe to determine concentration of target present. It was also indicated that this system has a potential to identify mismatches and insertions. The aim of this work was to investigate experimental structures and conditions that permit strong exciplex emission for nucleic acid detectors, and show how such exciplexes can register the presence of mismatches as required in SNP analysis. This study revealed that the hybridisation of 5'-bispyrenyl fluorophore to a DNA target results in formation of a fluorescent probe with high signal intensity change and specificity for detecting a complementary target in a homogeneous system. Detection of SNP mutations using this split-probe system is a highly specific, simple, and accessible method to meet the rigorous requirements of pharmacogenomic studies. Thus, it is possible for the system to act as SNP detectors and it shows promise for future applications in genetic testing.

  1. Probes for anionic cell surface detection

    Science.gov (United States)

    Smith, Bradley D.

    2013-03-05

    Embodiments of the present invention are generally directed to compositions comprising a class of molecular probes for detecting the presence of anionic cell surfaces. Embodiments include compositions that are enriched for these compositions and preparations, particularly preparations suitable for use as laboratory/clinical reagents and diagnostic indicators, either alone or as part of a kit. An embodiment of the invention provides for a highly selective agent useful in the discernment and identification of dead or dying cells, such as apoptotic cells, in a relatively calcium-free environment. An embodiment of the invention provides a selective agent for the identification of bacteria in a mixed population of bacterial cells and nonbacterial cells.

  2. Study, development and clinical evaluation of a per-operative γ imager

    International Nuclear Information System (INIS)

    Menard, Laurent

    1999-01-01

    The precise localization and complete surgical ablation of tumors are one of the most important procedures in cancer treatment. In that context, the use, in operating room, of light hand-held detectors associated to radiopharmaceutical compounds for tumor labelling, plays a significant role in assisting surgeons in real-time detection of lesion. The POCI gamma imaging probe (Per-Operative Compact Imager), which is presented here, is precisely dedicated to improve the radio-guided operative cancer surgery efficiency by bringing a new tool discriminating between healthy and pathological tissues. To match the specifications of intra-operative detection, we chose to build our camera around an intensified position sensitive diode which appeared to be particularly suitable to achieve a high resolution small size imager. The optimal geometry of two gamma detection head modules, composed of parallel hole collimators and scintillation crystals, was then investigated by numerical simulations. From these technological solutions, a first prototype of POCI with a 24 mm diameter field of view has been developed. Its characterization has put forward a millimeter spatial resolution and a detection efficiency comparable to that of clinical gamma cameras and in agreement with the numerical predictions. Finally, in collaboration with Gustave Roussy, a first clinical evaluation of the POCI camera has been performed for sentinel ganglion pre-operative localization in patients afflicted by malignant melanomas or breast cancers. The preliminary results have already shown that the performances of POCI are compatible with intraoperative imaging purposes and suggest how this camera can boost the success rate of tumor removal surgeries for other cancerous diseases. (author)

  3. Developing detection efficiency standards for atom probe tomography

    Science.gov (United States)

    Prosa, Ty J.; Geiser, Brian P.; Lawrence, Dan; Olson, David; Larson, David J.

    2014-08-01

    Atom Probe Tomography (APT) is a near-atomic-scale analytical technique which, due to recent advances in instrumentation and sample preparation techniques, is being used on a variety of 3D applications. Total system detection efficiency is a key parameter for obtaining accurate spatial reconstruction of atomic coordinates from detected ions, but experimental determination of efficiency can be difficult. This work explores new ways to measure total system detection efficiency as well as the specimen characteristics necessary for such measurements. Composite specimens composed of a nickel/chromium multilayer core, National Institute of Standards and Technology Standard Reference Material 2135c, encapsulated with silver, silicon, or nickel were used to demonstrate the suitability of this approach for providing a direct measurement of APT efficiency. Efficiency measurements based on this multilayer encapsulated in nickel are reported.

  4. The gamma-ray-flux PDF from galactic halo substructure

    International Nuclear Information System (INIS)

    Lee, Samuel K.; Ando, Shin'ichiro; Kamionkowski, Marc

    2009-01-01

    One of the targets of the recently launched Fermi Gamma-ray Space Telescope is a diffuse gamma-ray background from dark-matter annihilation or decay in the Galactic halo. N-body simulations and theoretical arguments suggest that the dark matter in the Galactic halo may be clumped into substructure, rather than smoothly distributed. Here we propose the gamma-ray-flux probability distribution function (PDF) as a probe of substructure in the Galactic halo. We calculate this PDF for a phenomenological model of halo substructure and determine the regions of the substructure parameter space in which the PDF may be distinguished from the PDF for a smooth distribution of dark matter. In principle, the PDF allows a statistical detection of substructure, even if individual halos cannot be detected. It may also allow detection of substructure on the smallest microhalo mass scales, ∼ M ⊕ , for weakly-interacting massive particles (WIMPs). Furthermore, it may also provide a method to measure the substructure mass function. However, an analysis that assumes a typical halo substructure model and a conservative estimate of the diffuse background suggests that the substructure PDF may not be detectable in the lifespan of Fermi in the specific case that the WIMP is a neutralino. Nevertheless, for a large range of substructure, WIMP annihilation, and diffuse background models, PDF analysis may provide a clear signature of substructure

  5. Detection limit of 238U by gamma spectrometry

    International Nuclear Information System (INIS)

    Tartaglione, A.; Blostein, J.; Mayer, R

    2004-01-01

    The detection limit of 238 U was determined by gamma spectra measurements of a depleted uranium sample using four NaI(Tl) scintillators in a compact arrangement.The sample was shielded with 5 and 10 cm of lead.Two different methods for data processing were used and compared.It was established that an appropriate array of 40 detectors could establish the presence of 220 g of this material in only 5 minutes [es

  6. Assessment of Laparoscopic Skills Performance: 2D Versus 3D Vision and Classic Instrument Versus New Hand-Held Robotic Device for Laparoscopy.

    Science.gov (United States)

    Leite, Mariana; Carvalho, Ana F; Costa, Patrício; Pereira, Ricardo; Moreira, Antonio; Rodrigues, Nuno; Laureano, Sara; Correia-Pinto, Jorge; Vilaça, João L; Leão, Pedro

    2016-02-01

    Laparoscopic surgery has undeniable advantages, such as reduced postoperative pain, smaller incisions, and faster recovery. However, to improve surgeons' performance, ergonomic adaptations of the laparoscopic instruments and introduction of robotic technology are needed. The aim of this study was to ascertain the influence of a new hand-held robotic device for laparoscopy (HHRDL) and 3D vision on laparoscopic skills performance of 2 different groups, naïve and expert. Each participant performed 3 laparoscopic tasks-Peg transfer, Wire chaser, Knot-in 4 different ways. With random sequencing we assigned the execution order of the tasks based on the first type of visualization and laparoscopic instrument. Time to complete each laparoscopic task was recorded and analyzed with one-way analysis of variance. Eleven experts and 15 naïve participants were included. Three-dimensional video helps the naïve group to get better performance in Peg transfer, Wire chaser 2 hands, and Knot; the new device improved the execution of all laparoscopic tasks (P < .05). For expert group, the 3D video system benefited them in Peg transfer and Wire chaser 1 hand, and the robotic device in Peg transfer, Wire chaser 1 hand, and Wire chaser 2 hands (P < .05). The HHRDL helps the execution of difficult laparoscopic tasks, such as Knot, in the naïve group. Three-dimensional vision makes the laparoscopic performance of the participants without laparoscopic experience easier, unlike those with experience in laparoscopic procedures. © The Author(s) 2015.

  7. Possibility of observing high energy neutrinos from gamma bursts, with the Antanares telescope, feasibility study; Possibilite d'observation, par le telescope antares, de neutrinos de haute energie associes aux sursauts gamma et validation des techniques de detection a l'aide d'un prototype

    Energy Technology Data Exchange (ETDEWEB)

    Kouchner, A

    2001-04-01

    The European Antares collaboration intends to build a deep-sea neutrino telescope with a detection surface of about 1/10 km{sup 2} in the Mediterranean sea. The universe is transparent to neutrinos, so their study provides a unique means of improving our knowledge of the nature and origin of cosmic rays and their emission from the most powerful astrophysical sources in the cosmos. Neutrinos also offer the possibility of opening a new energy window (E>TeV) for observation of the universe. The first part of the thesis is dedicated to a study of the possibility of using the future telescope to look for correlations between gamma-ray bursts and high-energy neutrinos. It is based, on one hand, on the predictions of neutrino fluxes from gamma-ray bursts in the framework of the theoretical model of 'fireballs', and, on the other hand, on the temporal properties of the gamma-ray bursts in the 4. BATSE catalogue. The second part of the thesis presents the results obtained with a prototype detector line deployed, at the end of 1999, some forty km south-west off Marseilles. The objective was to operate a complete apparatus, similar to the future detector lines, from the shore, and under realistic conditions. Data from 7 photomultiplier tubes disposed along the detector line were transmitted through 37 km of optical fiber to the shore, where they were used to reconstruct tracks due to atmospheric muons, thus validating the detection principles and methods. (author)

  8. Mobile Probing and Probes

    DEFF Research Database (Denmark)

    Duvaa, Uffe; Ørngreen, Rikke; Weinkouff Mathiasen, Anne-Gitte

    2013-01-01

    Mobile probing is a method, developed for learning about digital work situations, as an approach to discover new grounds. The method can be used when there is a need to know more about users and their work with certain tasks, but where users at the same time are distributed (in time and space......). Mobile probing was inspired by the cultural probe method, and was influenced by qualitative interview and inquiry approaches. The method has been used in two subsequent projects, involving school children (young adults at 15-17 years old) and employees (adults) in a consultancy company. Findings point...... to mobile probing being a flexible method for uncovering the unknowns, as a way of getting rich data to the analysis and design phases. On the other hand it is difficult to engage users to give in depth explanations, which seem easier in synchronous dialogs (whether online or face2face). The development...

  9. Mobile Probing and Probes

    DEFF Research Database (Denmark)

    Duvaa, Uffe; Ørngreen, Rikke; Weinkouff, Anne-Gitte

    2012-01-01

    Mobile probing is a method, which has been developed for learning about digital work situations, as an approach to discover new grounds. The method can be used when there is a need to know more about users and their work with certain tasks, but where users at the same time are distributed (in time...... and space). Mobile probing was inspired by the cultural probe method, and was influenced by qualitative interview and inquiry approaches. The method has been used in two subsequent projects, involving school children (young adults at 15-17 years old) and employees (adults) in a consultancy company. Findings...... point to mobile probing being a flexible method for uncovering the unknowns, as a way of getting rich data to the analysis and design phases. On the other hand it is difficult to engage users to give in depth explanations, which seem easier in synchronous dialogs (whether online or face2face...

  10. The use of "9"9"mTc-Al_2O_3 for detection of sentinel lymph nodes in breast cancer

    International Nuclear Information System (INIS)

    Sinilkin, I.; Chernov, V.; Medvedeva, A.; Zeltchan, R.; Slonimskaya, E.; Doroshenko, A.; Varlamova, N.; Skuridin, V.

    2016-01-01

    Purpose: to study the feasibility of using the new radiopharmaceutical based on the technetium-99m-labeled gamma-alumina for identification of sentinel lymph nodes (SLNs) in breast cancer patients. The study included two groups of breast cancer patients who underwent single photon emission computed tomography (SPECT) and intraoperaive gamma probe identification of sentinel lymph nodes (SLNs). To identify SLNs, the day before surgery Group I patients (n = 34) were injected with radioactive "9"9"mTc-Al_2O_3, and Group II patients (n = 30) received "9"9"mTc-labeled phytate colloid. A total of 37 SLNs were detected in Group I patients. The number of identified SLNs per patient ranged from 1 to 2 (the average number of identified SLNs was 1.08). Axillary lymph nodes were the most common site of SLN localization. 18 hours after "9"9"mTc-Al_2O_3 injection, the percentage of its accumulation in the SLN was 7–11% (of the counts in the injection site) by SPECT and 17–31% by gamma probe detection. In Group II SLNs were detected in 27 patients. 18 hours after injection of the phytate colloid the percentage of its accumulation in the SLN was 1.5–2% out of the counts in the injection site by SPECT and 4–7% by gamma probe. The new radiopharmaceutical based on the "9"9"mTc-Al_2O_3 demonstrates high accumulation in SLNs without redistribution through the entire lymphatic basin. The sensitivity and specificity of "9"9"mTc-Al_2O_3 were 100% for both SPECT and intraoperative gamma probe identification.

  11. Hand-Held Photometer for Instant On-Spot Quantification of Nucleic Acids, Proteins, and Cells.

    Science.gov (United States)

    Li, Shi-Hao; Jain, Abhinav; Tscharntke, Timo; Arnold, Tobias; Trau, Dieter W

    2018-02-20

    This paper presents a novel hand-held photometer, termed "Photopette", for on-spot absorbance measurements of biochemical analytes. The Photopette is a multicomponent, highly portable device with an overall weight of 160 g, which fits within 202 mm × 47 mm × 42 mm. Designed in the form factor of a micropipette, Photopette integrates a photodiode detector with light emitting diodes (LEDs) to form a highly customizable photometer which supports a wide variety of applications within the wavelengths between 260 and 1050 nm. A dual-purpose disposable reflective tip was designed to act as a sample holder and a light-reflecting system, which is in stark contrast to the operation of mainstream spectrophotometers and photometers. Small volume analytes may be measured with low sample loss using this proprietary CuveTip. A user-friendly software application running on smart devices was developed to control and read the values from Photopette via a low-energy Bluetooth link. This one-step strategy allows measurements on-spot without sample transfer, minimizing cross-contamination and human error. The results reported in this paper demonstrate Photopette's great potential to quantify DNA, direct protein, and cell density directly within the laminar flow hood. Results are compared with a Nanodrop 2000c spectrophotometer, a mainstream spectrophotometer for small-volume measurements.

  12. Associated-particle sealed-tube neutron probe: Detection of explosives, contraband, and nuclear materials

    International Nuclear Information System (INIS)

    Rhodes, E.; Dickerman, C.E.

    1996-01-01

    Continued research and development of the APSTNG shows the potential for practical field use of this technology for detection of explosives, contraband, and nuclear materials. The APSTNG (associated-particle sealed-tube generator) inspects the item to be examined using penetrating 14-MeV neutrons generated by the deuterium-tritium reaction inside a compact accelerator tube. An alpha detector built into the sealed tube detects the alpha-particle associated with each neutron emitted in a cone encompassing the volume to be inspected. Penetrating high-energy gamma-rays from the resulting neutron reactions identify specific nuclides inside the volume. Flight-times determined from the detection times of gamma-rays and alpha-particles separate the prompt and delayed gamma-ray spectra and allow a coarse 3-D image to be obtained of nuclides identified in the prompt spectrum. The generator and detectors can be on the same side of the inspected object, on opposite sides, or with intermediate orientations. Thus, spaces behind walls and other confined regions can be inspected. Signals from container walls can be discriminated against using the flight-time technique. No collimators or shielding are required, the neutron generator is relatively small, and commercial-grade electronics are employed. The use of 14-MeV neutrons yields a much higher cross-section for detecting nitrogen than that for systems based on thermal-neutron reactions alone, and the broad range of elements with significant 14-MeV neutron cross-sections extends explosives detection to other elements including low-nitrogen compounds, and allows detection of many other substances. Proof-of-concept experiments have been successfully performed for conventional explosives, chemical warfare agents, cocaine, and fissionable materials

  13. Detection of Listeria species in Gamma irradiated Fishes during Storage periods

    International Nuclear Information System (INIS)

    Mohamed, W.S.

    2011-01-01

    This investigation was carried out to detect the post irradiation recovery and growth of Listeria species encountered in frozen whole Tilapia fishes ,Tilapia fillet and frozen Hamour fillets fishes (-18 degree C) irradiated at 1, 2, 2.5 and 3 kGy. The pathogen was eliminated at a dose of 2.5 kGy of gamma radiation. The presence of the microorganism was monitored for sex months on appropriate selective media. The ability of recovery of the organism from irradiation damage was not influenced by the kind of fish. No increased counts of the organism in irradiated fishes at 2.5 kGy of gamma radiation was noticed during 6 months of freezing storage at -18 degree C. This study also aimed to evaluate the effect of different enrichment procedures on the detection of Listeria species in fishes

  14. Sandwich hybridization probes for the detection of Pseudo-nitzschia (Bacillariophyceae) species: An update to existing probes and a description of new probes.

    Science.gov (United States)

    Bowers, Holly A; Marin, Roman; Birch, James M; Scholin, Christopher A

    2017-12-01

    New sandwich hybridization assay (SHA) probes for detecting Pseudo-nitzschia species (P. arenysensis, P. fraudulenta, P. hasleana, P. pungens) are presented, along with updated cross-reactivity information on historical probes (SHA and FISH; fluorescence in situ hybridization) targeting P. australis and P. multiseries. Pseudo-nitzschia species are a cosmopolitan group of diatoms that produce varying levels of domoic acid (DA), a neurotoxin that can accumulate in finfish and shellfish and transfer throughout the food web. Consumption of infected food sources can lead to illness in humans (amnesic shellfish poisoning; ASP) and marine wildlife (domoic acid poisoning; DAP). The threat of human illness, along with economic loss from fishery closures has resulted in the implementation of monitoring protocols and intensive ecological studies. SHA probes have been instrumental in some of these efforts, as the technique performs well in complex heterogeneous sample matrices and has been adapted to benchtop and deployable (Environmental Sample Processor) platforms. The expanded probe set will enhance future efforts towards understanding spatial, temporal and successional patterns in species during bloom and non-bloom periods. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Experimental techniques for the detection of the high energy gamma rays of cosmic origin

    International Nuclear Information System (INIS)

    Dumitrescu, Gh.; Angelescu, T.; Radu, A.A.

    2002-01-01

    The observation of high energy gamma rays of cosmic origin in the early 90 by Volcano Ranch experiment opened a new direction of study in astrophysics. The very high energy and the very low flux of these gamma rays, posed numerous detection problems which in turn were the object of a very intense research activity. The present article tries to review the detection techniques for the high energy gamma rays of cosmic origin. In the 'Introduction' we summarize the specific problems involved in the detection of this type of radiation. 'Chapter 1' presents the classic technique based on the use of scintillation detectors. 'Chapter 2' includes the imaging atmospheric Cherenkov technique (IACT) and the sampling wavefront technique. 'Chapter 3' is dedicated to the detection of the atmospheric nitrogen. 'Chapter 4' describes issues related to the calibration of the detectors, the cross checking of the experimental data, the use of the Monte Carlo simulations and the use of the density observed at a distance of 600 m S(600), in order to estimate the primary energy. The characteristics of some future developments of the above presented techniques are included in the last chapter. (authors)

  16. Electrogenerated chemiluminescence biosensing for the detection of prostate PC-3 cancer cells incorporating antibody as capture probe and ruthenium complex-labelled wheat germ agglutinin as signal probe

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Haiying [Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi’an 710062 (China); Department of Chemistry, Yuncheng University, Yuncheng 044300 (China); Li, Zhejian; Shan, Meng; Li, Congcong; Qi, Honglan; Gao, Qiang [Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi’an 710062 (China); Wang, Jinyi [College of Science and College of Veterinary Medicine, Northwest A& F University, Yangling 712100 (China); Zhang, Chengxiao, E-mail: cxzhang@snnu.edu.cn [Key Laboratory of Applied Surface and Colloid Chemistry, Ministry of Education, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi’an 710062 (China)

    2015-03-10

    Highlights: • A novel biosensor was developed for the detection of prostate cancer cells. • The selectivity of the biosensor was improved using antibody as capture probe. • The biosensor showed the low extremely detection limit of 2.6 × 10{sup 2} cells mL{sup −1}. • The ruthenium complex-labelled WGA can be transported in the cell vesicles. - Abstract: A highly selective and sensitive electrogenerated chemiluminescence (ECL) biosensor for the detection of prostate PC-3 cancer cells was designed using a prostate specific antibody as a capture probe and ruthenium complex-labelled wheat germ agglutinin as a signal probe. The ECL biosensor was fabricated by covalently immobilising the capture probe on a graphene oxide-coated glassy carbon electrode. Target PC-3 cells were selectively captured on the surface of the biosensor, and then, the signal probe was bound with the captured PC-3 cells to form a sandwich. In the presence of tripropylamine, the ECL intensity of the sandwich biosensor was logarithmically directly proportion to the concentration of PC-3 cells over a range from 7.0 × 10{sup 2} to 3.0 × 10{sup 4} cells mL{sup −1}, with a detection limit of 2.6 × 10{sup 2} cells mL{sup −1}. The ECL biosensor was also applied to detect prostate specific antigen with a detection limit of 0.1 ng mL{sup −1}. The high selectivity of the biosensor was demonstrated in comparison with that of a lectin-based biosensor. The strategy developed in this study may be a promising approach and could be extended to the design of ECL biosensors for highly sensitive and selective detection of other cancer-related cells or cancer biomarkers using different probes.

  17. Electrogenerated chemiluminescence biosensing for the detection of prostate PC-3 cancer cells incorporating antibody as capture probe and ruthenium complex-labelled wheat germ agglutinin as signal probe

    International Nuclear Information System (INIS)

    Yang, Haiying; Li, Zhejian; Shan, Meng; Li, Congcong; Qi, Honglan; Gao, Qiang; Wang, Jinyi; Zhang, Chengxiao

    2015-01-01

    Highlights: • A novel biosensor was developed for the detection of prostate cancer cells. • The selectivity of the biosensor was improved using antibody as capture probe. • The biosensor showed the low extremely detection limit of 2.6 × 10 2 cells mL −1 . • The ruthenium complex-labelled WGA can be transported in the cell vesicles. - Abstract: A highly selective and sensitive electrogenerated chemiluminescence (ECL) biosensor for the detection of prostate PC-3 cancer cells was designed using a prostate specific antibody as a capture probe and ruthenium complex-labelled wheat germ agglutinin as a signal probe. The ECL biosensor was fabricated by covalently immobilising the capture probe on a graphene oxide-coated glassy carbon electrode. Target PC-3 cells were selectively captured on the surface of the biosensor, and then, the signal probe was bound with the captured PC-3 cells to form a sandwich. In the presence of tripropylamine, the ECL intensity of the sandwich biosensor was logarithmically directly proportion to the concentration of PC-3 cells over a range from 7.0 × 10 2 to 3.0 × 10 4 cells mL −1 , with a detection limit of 2.6 × 10 2 cells mL −1 . The ECL biosensor was also applied to detect prostate specific antigen with a detection limit of 0.1 ng mL −1 . The high selectivity of the biosensor was demonstrated in comparison with that of a lectin-based biosensor. The strategy developed in this study may be a promising approach and could be extended to the design of ECL biosensors for highly sensitive and selective detection of other cancer-related cells or cancer biomarkers using different probes

  18. Hard probes 2006 Asilomar

    CERN Multimedia

    2006-01-01

    "The second international conference on hard and electromagnetic probes of high-energy nuclear collisions was held June 9 to 16, 2006 at the Asilomar Conference grounds in Pacific Grove, California" (photo and 1/2 page)

  19. Sensitive and Selective Ratiometric Fluorescence Probes for Detection of Intracellular Endogenous Monoamine Oxidase A.

    Science.gov (United States)

    Wu, Xiaofeng; Li, Lihong; Shi, Wen; Gong, Qiuyu; Li, Xiaohua; Ma, Huimin

    2016-01-19

    Monoamine oxidase A (MAO-A) is known to widely exist in most cell lines in the body, and its dysfunction (unusually high or low levels of MAO-A) is thought to be responsible for several psychiatric and neurological disorders. Thus, a sensitive and selective method for evaluating the relative MAO-A levels in different live cells is urgently needed to better understand the function of MAO-A, but to our knowledge such a method is still lacking. Herein, we rationally design two new ratiometric fluorescence probes (1 and 2) that can sensitively and selectively detect MAO-A. The probes are constructed by incorporating a recognition group of propylamine into the fluorescent skeleton of 1,8-naphthalimide, and the detection mechanism is based on amine oxidation and β-elimination to release the fluorophore (4-hydroxy-N-butyl-1,8-naphthalimide), which is verified by HPLC analysis. Reaction of the probes with MAO-A produces a remarkable fluorescence change from blue to green, and the ratio of fluorescence intensity at 550 and 454 nm is directly proportional to the concentration of MAO-A in the ranges of 0.5-1.5 and 0.5-2.5 μg/mL with detection limits of 1.1 and 10 ng/mL (k = 3) for probes 1 and 2, respectively. Surprisingly, these probes show strong fluorescence responses to MAO-A but almost none to MAO-B (one of two isoforms of MAO), indicating superior ability to distinguish MAO-A from MAO-B. The high specificity of the probes for MAO-A over MAO-B is further supported by different inhibitor experiments. Moreover, probe 1 displays higher sensitivity than probe 2 and is thus investigated to image the relative MAO-A levels in different live cells, such as HeLa and NIH-3T3 cells. It is found that the concentration of endogenous MAO-A in HeLa cells is approximately 1.8 times higher than that in NIH-3T3 cells, which is validated by the result from an ELISA kit. Additionally, the proposed probes may find more uses in the specific detection of MAO-A between the two isoforms of MAO

  20. Intraoperative probe detecting β{sup −} decays in brain tumour radio-guided surgery

    Energy Technology Data Exchange (ETDEWEB)

    Solfaroli Camillocci, E., E-mail: elena.solfaroli@roma1.infn.it [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Bocci, V.; Chiodi, G. [INFN Sezione di Roma, Roma (Italy); Collamati, F. [INFN Sezione di Roma, Roma (Italy); Dip. Scienze di Base e Applicate per l' Ingegneria, Sapienza Univ. di Roma, Roma (Italy); Donnarumma, R.; Faccini, R.; Mancini Terracciano, C. [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Marafini, M. [INFN Sezione di Roma, Roma (Italy); Museo Storico della Fisica e Centro Studi e Ricerche ‘E. Fermi’, Roma (Italy); Mattei, I.; Muraro, S. [Center for Life Nano Science@Sapienza, Istituto Italiano di Tecnologia, Roma (Italy); Recchia, L. [INFN Sezione di Roma, Roma (Italy); Rucinski, A. [INFN Sezione di Roma, Roma (Italy); Dip. Scienze di Base e Applicate per l' Ingegneria, Sapienza Univ. di Roma, Roma (Italy); Russomando, A. [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Center for Life Nano Science@Sapienza, Istituto Italiano di Tecnologia, Roma (Italy); Toppi, M. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Traini, G. [Dip. Fisica, Sapienza Univ. di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Morganti, S. [INFN Sezione di Roma, Roma (Italy)

    2017-02-11

    Radio-guided surgery (RGS) is a technique to intraoperatively detect tumour remnants, favouring a radical resection. Exploiting β{sup −} emitting tracers provides a higher signal to background ratio compared to the established technique with γ radiation, allowing the extension of the RGS applicability range. We developed and tested a detector based on para-terphenyl scintillator with high sensitivity to low energy electrons and almost transparent to γs to be used as intraoperative probe for RGS with β{sup −} emitting tracer. Portable read out electronics was customised to match the surgeon needs. This probe was used for preclinical test on specific phantoms and a test on “ex vivo” specimens from patients affected by meningioma showing very promising results for the application of this new technique on brain tumours. In this paper, the prototype of the intraoperative probe and the tests are discussed; then, the results on meningioma are used to make predictions on the performance of the probe detecting residuals of a more challenging and more interesting brain tumour: the glioma.

  1. Detection of gamma-ray bursts from Andromeda

    International Nuclear Information System (INIS)

    Bulik, Tomasz; Coppi, Paolo S.; Lamb, Donald Q.

    1996-01-01

    If gamma-ray bursts originate in a corona around the Milky Way, it should also be possible to detect them from a similar corona around Andromeda. Adopting a simple model of high velocity neutron star corona, we evaluate the ability of instruments on existing missions to detect an excess of bursts toward Andromeda. We also calculate the optimal properties of an instrument designed to detect such an excess. We find that if the bursts radiate isotropically, an experiment with a sampling distance d max > or approx. 500 kpc could detect a significant excess of bursts in the direction of Andromeda in a few years of observation. If the radiation is beamed along the neutron star's direction of motion, an experiment with d max > or approx. 800 kpc would detect such an excess in a similar amount of time, provided that the width of the beam is greater than 10 deg. Lack of an excess toward Andromeda would therefore be compelling evidence that the bursts are cosmological in origin if made by an instrument at least 50 times more sensitive than BATSE, given current constraints on Galactic corona models. Comparisons with detailed dynamical calculations of the spatial distribution of high velocity neutron stars in the coronae around the Milky Way and Andromeda confirm these conclusions

  2. Extra-oral dental radiography for disaster victims using a flat panel X-ray detector and a hand-held X-ray generator.

    Science.gov (United States)

    Ohtani, M; Oshima, T; Mimasaka, S

    2017-12-01

    Forensic odontologists commonly incise the skin for post-mortem dental examinations when it is difficult to open the victim's mouth. However, it is prohibited by law to incise dead bodies without permission in Japan. Therefore, we attempted using extra-oral dental radiography, using a digital X-ray equipment with rechargeable batteries, to overcome this restriction. A phantom was placed in the prone position on a table, and three plain dental radiographs were used per case: "lateral oblique radiographs" for left and right posterior teeth and a "contact radiograph" for anterior teeth were taken using a flat panel X-ray detector and a hand-held X-ray generator. The resolving power of the images was measured by a resolution test chart, and the scattered X-ray dose was measured using an ionization chamber-type survey meter. The resolving power of the flat panel X-ray detector was 3.0 lp/mm, which was less than that of intra-oral dental methods, but the three extra-oral plain dental radiographs provided the overall dental information from outside of the mouth, and this approach was less time-consuming. In addition, the higher dose of scattered X-rays was laterally distributed, but the dose per case was much less than that of intra-oral dental radiographs. Extra-oral plain dental radiography can be used for disaster victim identification by dental methods even when it is difficult to open the mouth. Portable and rechargeable devices, such as a flat panel X-ray detector and a hand-held X-ray generator, are convenient to bring and use anywhere, even at a disaster scene lacking electricity and water.

  3. LNA probe-based assay for the detection of Tomato black ring virus isolates.

    Science.gov (United States)

    Hasiów-Jaroszewska, Beata; Rymelska, Natalia; Borodynko, Natasza

    2015-02-01

    Tomato black ring virus (TBRV) infects a wide range of economically important plant species worldwide. In the present study we developed a locked nucleic acid (LNA) real-time RT-PCR assay for accurate detection of genetically diverse TBRV isolates collected from different hosts. The assay based on the LNA probe has a wide detection range, high sensitivity, stability and amplification efficiency. The assay amplified all tested TBRV isolates, but no signal was observed for the RNA from other nepoviruses and healthy plant species. Under optimum reaction conditions, the detection limit was estimated around 17 copies of the TBRV target region in total RNA. Real-time RT-PCR with the LNA probe described in this paper will serve as a valuable tool for robust, sensitive and reliable detection of TBRV isolates. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. A luminescence-based probe for sensitive detection of hydrogen peroxide in seconds

    International Nuclear Information System (INIS)

    Zscharnack, Kristin; Kreisig, Thomas; Prasse, Agneta A.; Zuchner, Thole

    2014-01-01

    Highlights: • We describe a novel probe for the sensitive detection of H 2 O 2 . • H 2 O 2 quenches the luminescence of a complex consisting of phthalic acid and terbium ions. • A stable fluorescence signal is generated immediately after mixing probe and sample. • The PATb probe detects H 2 O 2 over four orders of magnitude. - Abstract: Here, we present a fast and simple hydrogen peroxide assay that is based on time-resolved fluorescence. The emission intensity of a complex consisting of terbium ions (Tb 3+ ) and phthalic acid (PA) in HEPES buffer is quenched in the presence of H 2 O 2 and this quenching is concentration-dependent. The novel PATb assay detects hydrogen peroxide at a pH range from 7.5 to 8.5 and with a detection limit of 150 nmol L −1 at pH 8.5. The total assay time is less than 1 min. The linear range of the assay can be adapted by a pH adjustment of the aqueous buffer and covers a concentration range from 310 nmol L −1 to 2.56 mmol L −1 in total which encompasses four orders of magnitude. The assay is compatible with high concentrations of all 47 tested inorganic and organic compounds. The PATb assay was applied to quantify H 2 O 2 in polluted river water samples. In conclusion, this fast and easy-to-use assay detects H 2 O 2 with high sensitivity and precision

  5. Developpement of a photoaffinity probe for the sensitive detection of matrix metallo-protease active forms from complex biological systems

    International Nuclear Information System (INIS)

    Nury, Catherine

    2012-01-01

    A new activity-based probe able to covalently modify the active site of proteases belonging to the matrix metallo-protease family (MMPs) has been developed in this thesis project. The probe was shown to behave as potent inhibitor of several MMPs, with nanomolar Ki values. This probe was also able to modify specifically only the free active site of MMPs, with particular high yields of cross-linking varying from 50 % to 11 %, depending of the MMPs tested. Using radioactivity as means of detection, this probe was able to detect active form of MMPs with a threshold of 1 femto-mole. Applied to the study of bronchoalveolar fluids (BAL) from mice exposed to nanoparticles by a lung aspiration protocol, this probe revealed the presence of the catalytic domain of MMP-12 under its active form, but not in control animals. When used to detect active form of MMPs from extracts obtained from human arteries of patient suffering from atherosclerosis, the probe was not able to detect such MMP active forms. Despite this negative result, the detection of active form of MMP in pathological fluid like BAL has never been reported before this work. Having validated this novel MMP activity-based probe, it will be possible to use it now for detecting MMPs from other pathological fluids or tissues extracts in which MMPs can be good markers of the pathology. (author) [fr

  6. In-Season Yield Prediction of Cabbage with a Hand-Held Active Canopy Sensor.

    Science.gov (United States)

    Ji, Rongting; Min, Ju; Wang, Yuan; Cheng, Hu; Zhang, Hailin; Shi, Weiming

    2017-10-08

    Efficient and precise yield prediction is critical to optimize cabbage yields and guide fertilizer application. A two-year field experiment was conducted to establish a yield prediction model for cabbage by using the Greenseeker hand-held optical sensor. Two cabbage cultivars (Jianbao and Pingbao) were used and Jianbao cultivar was grown for 2 consecutive seasons but Pingbao was only grown in the second season. Four chemical nitrogen application rates were implemented: 0, 80, 140, and 200 kg·N·ha -1 . Normalized difference vegetation index (NDVI) was collected 20, 50, 70, 80, 90, 100, 110, 120, 130, and 140 days after transplanting (DAT). Pearson correlation analysis and regression analysis were performed to identify the relationship between the NDVI measurements and harvested yields of cabbage. NDVI measurements obtained at 110 DAT were significantly correlated to yield and explained 87-89% and 75-82% of the cabbage yield variation of Jianbao cultivar over the two-year experiment and 77-81% of the yield variability of Pingbao cultivar. Adjusting the yield prediction models with CGDD (cumulative growing degree days) could make remarkable improvement to the accuracy of the prediction model and increase the determination coefficient to 0.82, while the modification with DFP (days from transplanting when GDD > 0) values did not. The integrated exponential yield prediction equation was better than linear or quadratic functions and could accurately make in-season estimation of cabbage yields with different cultivars between years.

  7. Eddy current array probe for detection of surface breaking cracks in the extrados of feeder bends

    International Nuclear Information System (INIS)

    Obrutsky, L.S.; Cassidy, R.A.; Chaplin, K.; Martin, P.; Bureau, J.F.

    2006-01-01

    A new eddy current array probe has been implemented as a straightforward and promising technique for detection of outer diameter (OD) surface-breaking cracks on the extrados of feeder bends. The design is based on previous work performed at AECL, which had demonstrated that eddy current probes with laterally displaced transmit-receive coils can overcome some of the limitations of inspecting ferritic steel components for surface-breaking cracks. The Feeder Integrity Joint Program-CANDU Owners Group Inc. (FIJP-COG) Non-Destructive Evaluation (NDE) Team members commissioned AECL to work in collaboration with the probe manufacturer ZETEC, to develop a field usable eddy current array probe. The objective was to acquire a technique with the following capabilities: fast scanning non-contact inspection technique for surface breaking discontinuities; full inspection of the bend extrados OD surface in a single scan; ability to inspect first and second bends with similar settings and capabilities; permanent record for future reference; axial and circumferential crack detection in a single scan; capability to detect OD surface-breaking cracks, which can provide additional information to that provided by ultrasonic testing (UT) for flaw characterization, and detection threshold: Surface breaking cracks equivalent to a 0.5 mm deep, 10 mm long EDM notch located on the OD of the bend extrados. This paper discusses the basis for probe design, summarizes the experimental work to evaluate probe capabilities and analyzes the results from the field trial. (author)

  8. Eddy current array probe for detection of surface breaking cracks in the extrados of feeder bends

    Energy Technology Data Exchange (ETDEWEB)

    Obrutsky, L.S.; Cassidy, R.A.; Chaplin, K. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada)]. E-mail: obrutskyl@aecl.ca; Martin, P. [NB Power, Point Lepreau NGS, Point Lepreau, New Brunswick (Canada)]. E-mail: PMartin@nbpower.com; Bureau, J.F. [Zetec, Quebec, Quebec (Canada)]. E-mail: jean-francois.bureau@zetec.com

    2006-07-01

    A new eddy current array probe has been implemented as a straightforward and promising technique for detection of outer diameter (OD) surface-breaking cracks on the extrados of feeder bends. The design is based on previous work performed at AECL, which had demonstrated that eddy current probes with laterally displaced transmit-receive coils can overcome some of the limitations of inspecting ferritic steel components for surface-breaking cracks. The Feeder Integrity Joint Program-CANDU Owners Group Inc. (FIJP-COG) Non-Destructive Evaluation (NDE) Team members commissioned AECL to work in collaboration with the probe manufacturer ZETEC, to develop a field usable eddy current array probe. The objective was to acquire a technique with the following capabilities: fast scanning non-contact inspection technique for surface breaking discontinuities; full inspection of the bend extrados OD surface in a single scan; ability to inspect first and second bends with similar settings and capabilities; permanent record for future reference; axial and circumferential crack detection in a single scan; capability to detect OD surface-breaking cracks, which can provide additional information to that provided by ultrasonic testing (UT) for flaw characterization, and detection threshold: Surface breaking cracks equivalent to a 0.5 mm deep, 10 mm long EDM notch located on the OD of the bend extrados. This paper discusses the basis for probe design, summarizes the experimental work to evaluate probe capabilities and analyzes the results from the field trial. (author)

  9. Fluorescent probe encapsulated hydrogel microsphere for selective and reversible detection of Hg{sup 2+}

    Energy Technology Data Exchange (ETDEWEB)

    Song, Zhenhu; Wang, Fang; Qiang, Jian; Zhang, Zhijie; Chen, Yahui; Wang, Yong; Zhang, Wei; Chen, Xiaoqiang

    2017-03-15

    We developed a simple and sensitive hydrogel sensor in the form of microspheres by using fluorescence probe encapsulated within a hydrogel matrix for the detection of Hg{sup 2+}. The traditional fluorescence probes suspended in solution are not transportable and recoverable. To overcome these disadvantages, we devised poly(ethylene glycol) diacrylate-based hydrogel microspheres in which fluorescence probe (R19S) was embedded at high density. The functionalized hydrogel microspheres were prepared by combining a microfluidic device with UV light. The hydrogel microspheres-based sensor exhibited good selectivity to Hg{sup 2+} among various metal ions and high sensitivity with a detection limit of 90 nM. Furthermore, after binding with Hg{sup 2+}, the R19S encapsulated hydrogel microspheres can be separated from testing samples easily and treated with the solution containing KI to remove Hg{sup 2+} and realize reusable detection. The current work may offer a new method for Hg{sup 2+} recognition with a more efficient manner.

  10. Hand-arm vibration disorder among grass-cutter workers in Malaysia.

    Science.gov (United States)

    Azmir, Nor Azali; Ghazali, Mohd Imran; Yahya, Musli Nizam; Ali, Mohamad Hanafi

    2016-09-01

    Prolonged exposure to hand-transmitted vibration from grass-cutting machines has been associated with increasing occurrences of symptoms and signs of occupational diseases related to hand-arm vibration syndrome (HAVS). A cross-sectional study was carried out using an adopted HAVS questionnaire on hand-arm vibration exposure and symptoms distributed to 168 male workers from the grass and turf maintenance industry who use hand-held grass-cutting machines as part of their work. The prevalence ratio and symptom correlation to HAVS between high and low-moderate exposure risk groups were evaluated. There were positive HAVS symptoms relationships between the low-moderate exposure group and the high exposure group among hand-held grass-cutting workers. The prevalence ratio was considered high because there were indicators that fingers turned white and felt numb, 3.63, 95% CI [1.41, 9.39] and 4.24, 95% CI [2.18, 8.27], respectively. Less than 14.3% of workers stated that they were aware of the occupational hand-arm vibration, and it seemed to be related to the finger blanching and numbness. The results suggest that HAVS is under-diagnosed in Malaysia, especially in the agricultural sectors. More information related to safety and health awareness programmes for HAVS exposure is required among hand-held grass-cutting workers.

  11. Swift: A gamma ray burst MIDEX

    International Nuclear Information System (INIS)

    Barthelmy, Scott

    2001-01-01

    Swift is a first of its kind multiwavelength transient observatory for gamma-ray burst astronomy. It has the optimum capabilities for the next breakthroughs in determining the origin of gamma-ray bursts and their afterglows as well as using bursts to probe the early Universe. Swift will also perform the first sensitive hard X-ray survey of the sky. The mission is being developed by an international collaboration and consists of three instruments, the Burst Alert Telescope (BAT), the X-ray Telescope (XRT), and the Ultraviolet and Optical Telescope (UVOT). The BAT, a wide-field gamma-ray detector, will detect ∼1 gamma-ray burst per day with a sensitivity 5 times that of BATSE. The sensitive narrow-field XRT and UVOT will be autonomously slewed to the burst location in 20 to 70 seconds to determine 0.3-5.0 arcsec positions and perform optical, UV, and X-ray spectrophotometry. On-board measurements of redshift will also be done for hundreds of bursts. Swift will incorporate superb, low-cost instruments using existing flight-spare hardware and designs. Strong education/public outreach and follow-up programs will help to engage the public and astronomical community. Swift has been selected by NASA for development and launch in late 2003

  12. Mass amplifying probe for sensitive fluorescence anisotropy detection of small molecules in complex biological samples.

    Science.gov (United States)

    Cui, Liang; Zou, Yuan; Lin, Ninghang; Zhu, Zhi; Jenkins, Gareth; Yang, Chaoyong James

    2012-07-03

    Fluorescence anisotropy (FA) is a reliable and excellent choice for fluorescence sensing. One of the key factors influencing the FA value for any molecule is the molar mass of the molecule being measured. As a result, the FA method with functional nucleic acid aptamers has been limited to macromolecules such as proteins and is generally not applicable for the analysis of small molecules because their molecular masses are relatively too small to produce observable FA value changes. We report here a molecular mass amplifying strategy to construct anisotropy aptamer probes for small molecules. The probe is designed in such a way that only when a target molecule binds to the probe does it activate its binding ability to an anisotropy amplifier (a high molecular mass molecule such as protein), thus significantly increasing the molecular mass and FA value of the probe/target complex. Specifically, a mass amplifying probe (MAP) consists of a targeting aptamer domain against a target molecule and molecular mass amplifying aptamer domain for the amplifier protein. The probe is initially rendered inactive by a small blocking strand partially complementary to both target aptamer and amplifier protein aptamer so that the mass amplifying aptamer domain would not bind to the amplifier protein unless the probe has been activated by the target. In this way, we prepared two probes that constitute a target (ATP and cocaine respectively) aptamer, a thrombin (as the mass amplifier) aptamer, and a fluorophore. Both probes worked well against their corresponding small molecule targets, and the detection limits for ATP and cocaine were 0.5 μM and 0.8 μM, respectively. More importantly, because FA is less affected by environmental interferences, ATP in cell media and cocaine in urine were directly detected without any tedious sample pretreatment. Our results established that our molecular mass amplifying strategy can be used to design aptamer probes for rapid, sensitive, and selective

  13. Gamma-ray bursts observed by the watch experiment

    DEFF Research Database (Denmark)

    Lund, Niels; Brandt, Søren; Castro-Tirado, A. J.

    1991-01-01

    After two years in orbit the WATCH instruments on the GRANAT space observatory have localized seven gamma burst sources with better than 1° accuracy. In several cases, follow‐up observations with Schmidt telescopes have been made within a few days. Some of the bursts have also been detected...... by the distant space probes PVO and ULYSSES and there are, therefore, good prospects for obtaining much improved positions using the burst arrival times. The existence of the almost concurrent Schmidt plates could then become particularly interesting....

  14. Processing of Graphene combining Optical Detection and Scanning Probe Lithography

    Directory of Open Access Journals (Sweden)

    Zimmermann Sören

    2015-01-01

    Full Text Available This paper presents an experimental setup tailored for robotic processing of graphene with in-situ vision based control. A robust graphene detection approach is presented applying multiple image processing operations of the visual feedback provided by a high-resolution light microscope. Detected graphene flakes can be modified using a scanning probe based lithographical process that is directly linked to the in-situ optical images. The results of this process are discussed with respect to further application scenarios.

  15. Hemoglobin detection using carbon dots as a fluorescence probe.

    Science.gov (United States)

    Barati, Ali; Shamsipur, Mojtaba; Abdollahi, Hamid

    2015-09-15

    Herein, we have described the application of high fluorescent carbon dots (CDs) without any surface modification as a simple and fast responding fluorescence probe for sensitive and selective determination of hemoglobin (Hb) in the presence of H2O2. Although Hb itself was able to quench the fluorescence of CDs, based on the inner filter effect (IFE) of the protein that affects both excitation and emission spectra of CDs, the presence of H2O2 resulted in further improvement of the sensitivity of Hb detection. The assay is based on the reaction of Hb with H2O2 that generates reactive oxygen species including hydroxyl (OH•) and superoxide (O2(•-)) radicals under heme degradation and/or iron release from Hb and the subsequent reaction of hydroxyl radicals, as strong oxidizing agents, with CDs resulting in high fluorescence quenching. The proposed probe was used for determination of Hb in concentration range of 1-100 nM with a detection limit of 0.4 nM. The method was successfully applied to the determination of Hb in human blood samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Development of gamma probe technique for monitoring rooting pattern of pearl millet under field conditions

    International Nuclear Information System (INIS)

    Vittal, K.P.R.; Subbiah, B.V.

    1982-01-01

    For the root distribution studies, methods are not available to measure the growth in situ and in toto under field conditions without destroying the plants. A non-destructive method was developed for measuring the gamma activity in root using a probe that was administered through the stem. Five isotopes viz. 86 Rb, 134 Cs, 59 Fe, 65 Zn and 54 Mn tested, were found to represent almost similar rooting pattern for pearl millet from flowering to harvesting stages. Among these isotopes 59 Fe was found to be suitable for field use. This method also enabled to successfully monitor the root activity over time and avoided the sampling errors. Since laboratory processing of samples was eliminated, the process of measurement was hastened. (author)

  17. Probing the onset of structural instabilities as a tool for detection of staling of dairy milk: A permittivity and conductivity study

    Science.gov (United States)

    Madhurima, V.; Harindran, Aswini

    2018-05-01

    Dairy milk is a worldwide drink and a versatile raw material for food industries too. The major issue regarding dairy milk is their contamination by micro-organisms and subsequent spoiling. Pasteurization and sealed packing are used to minimize this contamination. The presence of pathogenic micro-organisms like psychrotrophs, reduces the pH of fresh milk by fermenting the lactose into lactic acid leading to the spoiling of milk. While there are various tests to check the spoilage of milk, there is no unique test to detect the onset of the complex dynamics of spoilage. There have been some studies on the dielectric properties of dairy milk but the primary method of identification of freshness of milk is through the measurement of pH. In this study, broadband dielectric spectroscopy is used as a tool to probe the spoiling of milk and that provides the information about the structural changes of milk during spoilage. The gamma dispersion explains the influence of free water content which is found to be a sensitive tool to probe the onset of milk spoilage process. The observations here are further backed by studies on the particle size and zeta potential.

  18. Absorption Related to Hand-Held Devices in Data Mode

    DEFF Research Database (Denmark)

    Andersen, Jørgen Bach; Nielsen, Jesper Ødum; Pedersen, Gert F.

    2016-01-01

    The human body has an influence on the radiation from handheld devices like smartphones, tablets and laptops, part of the energy is absorbed and the spatial distribution of the radiated part is modified. Previous studies of whole body absorp- tion have mainly been numerical or related to talk mode....... In the present paper an experimental study involving four volunteers and three different devices is performed from 0.5 to 3 GHz. The devices are a laptop, a tablet, and a smartphone all held in the lap. The 3D distribution of radiation is measured. Comparing the integrated power in the case of a person present...

  19. Comparison of the quantitative analysis performance between pulsed voltage atom probe and pulsed laser atom probe

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, J., E-mail: takahashi.3ct.jun@jp.nssmc.com [Advanced Technology Research Laboratories, Nippon Steel & Sumitomo Metal Corporation, 20-1 Shintomi, Futtsu-city, Chiba 293-8511 (Japan); Kawakami, K. [Advanced Technology Research Laboratories, Nippon Steel & Sumitomo Metal Corporation, 20-1 Shintomi, Futtsu-city, Chiba 293-8511 (Japan); Raabe, D. [Max-Planck Institut für Eisenforschung GmbH, Department for Microstructure Physics and Alloy Design, Max-Planck-Str. 1, 40237 Düsseldorf (Germany)

    2017-04-15

    Highlights: • Quantitative analysis in Fe-Cu alloy was investigated in voltage and laser atom probe. • In voltage-mode, apparent Cu concentration exceeded actual concentration at 20–40 K. • In laser-mode, the concentration never exceeded the actual concentration even at 20 K. • Detection loss was prevented due to the rise in tip surface temperature in laser-mode. • Preferential evaporation of solute Cu was reduced in laser-mode. - Abstract: The difference in quantitative analysis performance between the voltage-mode and laser-mode of a local electrode atom probe (LEAP3000X HR) was investigated using a Fe-Cu binary model alloy. Solute copper atoms in ferritic iron preferentially field evaporate because of their significantly lower evaporation field than the matrix iron, and thus, the apparent concentration of solute copper tends to be lower than the actual concentration. However, in voltage-mode, the apparent concentration was higher than the actual concentration at 40 K or less due to a detection loss of matrix iron, and the concentration decreased with increasing specimen temperature due to the preferential evaporation of solute copper. On the other hand, in laser-mode, the apparent concentration never exceeded the actual concentration, even at lower temperatures (20 K), and this mode showed better quantitative performance over a wide range of specimen temperatures. These results indicate that the pulsed laser atom probe prevents both detection loss and preferential evaporation under a wide range of measurement conditions.

  20. Construction and applications of DNA probes for detection of polychlorinated biphenyl-degrading genotypes in toxic organic-contaminated soil environments

    International Nuclear Information System (INIS)

    Walia, S.; Khan, A.; Rosenthal, N.

    1990-01-01

    Several DNA probes for polychlorinated biphenyl (PCB)-degrading genotypes were constructed from PCB-degrading bacteria. These laboratory-engineered DNA probes were used for the detection, enumeration, and isolation of specific bacteria degrading PCBs. Dot blot analysis of purified DNA from toxic organic chemical-contaminated soil bacterial communities showed positive DNA-DNA hybridization with a 32P-labeled DNA probe (pAW6194, cbpABCD). Less than 1% of bacterial colonies isolated from garden topsoil and greater than 80% of bacteria isolated from PCB-contaminated soils showed DNA homologies with 32P-labeled DNA probes. Some of the PCB-degrading bacterial isolates detected by the DNA probe method did not show biphenyl clearance. The DNA probe method was found to detect additional organisms with greater genetic potential to degrade PCBs than the biphenyl clearance method did. Results from this study demonstrate the usefulness of DNA probes in detecting specific PCB-degrading bacteria, abundance of PCB-degrading genotypes, and genotypic diversity among PCB-degrading bacteria in toxic chemical-polluted soil environments. We suggest that the DNA probe should be used with caution for accurate assessment of PCB-degradative capacity within soils and further recommend that a combination of DNA probe and biodegradation assay be used to determine the abundance of PCB-degrading bacteria in the soil bacterial community

  1. Rapid detection and identification of pathogenic mycobacteria by combining radiometric and nucleic acid probe methods

    International Nuclear Information System (INIS)

    Ellner, P.D.; Kiehn, T.E.; Cammarata, R.; Hosmer, M.

    1988-01-01

    The combination of radiometric methodology (BACTEC 12B) and probe technology for recovery and identification of mycobacteria was studied in two large hospital laboratories. The sediment from vials with positive growth indices was tested with DNA probes specific for Mycobacterium tuberculosis, Mycobacterium avium, and Mycobacterium intracellulare. The sensitivity of the radiometric method and the specificity of the probes resulted in a marked reduction in the time to the final report. Biochemical testing could be eliminated on isolates giving a positive reaction with one of the probes. Some 176 isolates of M. tuberculosis, 110 of M. avium, and 5 of M. intracellulare were recovered. Two-thirds of these isolates were detected and identified within 2 weeks of inoculation and the remainder was detected by 4 weeks, a reduction of 5 to 7 weeks to the final report

  2. Sensitive fluorescence on-off probes for the fast detection of a chemical warfare agent mimic.

    Science.gov (United States)

    Khan, Muhammad Shar Jhahan; Wang, Ya-Wen; Senge, Mathias O; Peng, Yu

    2018-01-15

    Two highly sensitive probes bearing a nucleophilic imine moiety have been utilized for the selective detection of chemical warfare agent (CWA) mimics. Diethyl chlorophosphate (DCP) was used as mimic CWAs. Both iminocoumarin-benzothiazole-based probes not only demonstrated a remarkable fluorescence ON-OFF response and good recognition, but also exhibited fast response times (10s) along with color changes upon addition of DCP. Limits of detection for the two sensors 1 and 2 were calculated as 0.065μM and 0.21μM, respectively, which are much lower than most other reported probes. These two probes not only show high sensitivity and selectivity in solution, but can also be applied for the recognition of DCP in the gas state, with significant color changes easily observed by the naked eye. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Detecting sentinel lymph nodes in caner cases of lower and middle rectum following lymphoscintigraphy

    International Nuclear Information System (INIS)

    Dontshev, M.; Dimitrov, D.; Deliysky, T.; Tsarowska, T.; Slavova, M.; Dekova, M.

    2006-01-01

    Full text: The lymphoscintigraphy and the interoperative gamma probing for through detection of the marked with radiocolloid sentinel lymph nodes (SLN) in the cases of patients having cancer in the lower and middle third of the rectum (CLMTR) are with minimum clinical experience in Bulgaria. The aim of the study is to examine the elaboration on the subject and introduction of nuclear medical methods for preoperative marking and representation of SLN and their interoperative finding thanks to gamma probing in the cases of CLMTR. This research covers 14 patients having CLMTR (3 females and 11 males) at the age of 55 - 80 (average 76,5), of whom 17 - 20 hours before the operation was carried out lymphoscintigraphy of two-headed SPECT gamma camera Toshiba CGA7200UI with 99mTc colloid applied transanal submycotic. The interoperative finding of SLN was made by the means of detection with manual gamma probe Silicone instruments. The lymphoscintigraphy visualized in 13 patients 11 SLN, and in one patient the examination was negative. The interoperative gamma sounding established the presence of activity in 12 SLN, 8 of them mezenterial and 4 of them - extramezenterial. The immunohistological examination of the biopsied 12 SLN found metastasis in two mezenterial SLN. In the rest 10 SLN there were no indications for metastatic process. The preliminary results show that the used from us nuclear medical methods are applicable for marking and finding of SLN in the cases of CLMTR aiming improvement the staging of the illness

  4. Vibration produced by hand-held olive electrical harvesters

    Directory of Open Access Journals (Sweden)

    Emanuele Cerruto

    2012-09-01

    Full Text Available The paper reports the results of some laboratory and field tests aimed at assessing the acceleration levels transmitted to the hand-arm system by electric portable harvesters for olive. Four harvesting heads, different for shape and kinematic system, and five bars, different for diameter, length and material (aluminium and carbon fibre, were used in assembling eleven harvesters. The vibrations were measured in two points, next to the handgrips. The laboratory tests allowed the evaluation of the acceleration levels in standard controlled conditions, while the field tests allowed the assessing of the effects of the tree canopy with respect to the no load running. The laboratory tests showed that in reducing the vibration level plays a major role the kinematic system of the harvesting head and then the bar material. The classical flap-type harvester produced accelerations of around 20 m/s2, while by using a harvesting head with two parts in opposite movement, the accelerations were lowered to about 6 m/s2. The use of carbon fibres for the bars, besides the reduction in weight, produced also a reduction in acceleration (from 21 to 16 m/s2. The field tests proved that the tree canopy had a negative effect on the vibrations transmitted to the hand-arm system, especially when the aluminium bar of small diameter was used.

  5. Comparison of the quantitative analysis performance between pulsed voltage atom probe and pulsed laser atom probe.

    Science.gov (United States)

    Takahashi, J; Kawakami, K; Raabe, D

    2017-04-01

    The difference in quantitative analysis performance between the voltage-mode and laser-mode of a local electrode atom probe (LEAP3000X HR) was investigated using a Fe-Cu binary model alloy. Solute copper atoms in ferritic iron preferentially field evaporate because of their significantly lower evaporation field than the matrix iron, and thus, the apparent concentration of solute copper tends to be lower than the actual concentration. However, in voltage-mode, the apparent concentration was higher than the actual concentration at 40K or less due to a detection loss of matrix iron, and the concentration decreased with increasing specimen temperature due to the preferential evaporation of solute copper. On the other hand, in laser-mode, the apparent concentration never exceeded the actual concentration, even at lower temperatures (20K), and this mode showed better quantitative performance over a wide range of specimen temperatures. These results indicate that the pulsed laser atom probe prevents both detection loss and preferential evaporation under a wide range of measurement conditions. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Construction of static 3D ultrasonography image by radiation beam tracking method from 1D array probe

    Energy Technology Data Exchange (ETDEWEB)

    Doh, Il; Kim, Yong Tae; Ahn, Bong Young [Center for Medical Metrology, Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of); Kim, Kwang Youn [Meta biomed Co.,Ltd, Cheongju (Korea, Republic of)

    2015-04-15

    This paper describes the construction of a static 3D ultrasonography image by tracking the radiation beam position during the handy operation of a 1D array probe to enable point-of-care use. The theoretical model of the transformation from the translational and rotational information of the sensor mounted on the probe to the reference Cartesian coordinate system was given. The signal amplification and serial communication interface module was made using a commercially available sensor. A test phantom was also made using silicone putty in a donut shape. During the movement of the hand-held probe, B-mode movie and sensor signals were recorded. B-mode images were periodically selected from the movie, and the gray levels of the pixels for each image were converted to the gray levels of 3D voxels. 3D and 2D images of arbitrary cross-section of the B-mode type were also constructed from the voxel data, and agreed well with the shape of the test phantom.

  7. Electronically tuned sulfonamide-based probes with ultra-sensitivity for Ga"3"+ or Al"3"+ detection in aqueous solution

    International Nuclear Information System (INIS)

    Kumar, Ashwani; Chae, Pil Seok

    2017-01-01

    Three electronically tuned fluorescent probes (1–3) were synthesized by conjugating a fluorescent unit to N,N-bis-(hydroxyethyl)ethylenediamine. Probe 1 bearing an electron-deficient naphthalenedimide unit did not give a fluorescence response to the presence of various metal ions including monovalent metal ions (Na"+, K"+, and Ag"+), divalent metal ions (Ca"2"+, Cd"2"+, Co"2"+, Ni"2"+, Cu"2"+, Hg"2"+, Pb"2"+, and Zn"2"+) and trivalent metal ions (Al"3"+, Ga"3"+, Fe"3"+, and Cr"3"+) in an aqueous solution. By contrast, probes 2 and 3 possessing 1,8-naphthalimide and pyrene fluorophores, respectively, exhibited selective fluorescent “OFF-ON” behaviors as a result of Ga"3"+/Al"3"+ binding among the diverse metal ions, suggesting the importance of fluorophore electronic character with regard to metal ion sensing. The ethylenediamine analog of probe 3, corresponding to probe 4, was unable to yield a significant change in fluorescence intensity in the presence of any metal ions tested here, revealing the essential role of two hydroxyl groups for metal ion binding. A high association constant of K_a = 2.99 × 10"5 M"−"1 was obtained for probe 3 with Ga"3"+, with a limit of detection (LOD) of 10 nM. This LOD is the lowest value known for Ga"3"+ detection using chemical sensors. Along with an increase in aggregate sizes, PET suppression of probes upon metal ion binding was the primary contributor to the enhancement in fluorescence emission necessary for the sensitive detection of the target ions. The probe-metal ion complexes were fully characterized via TEM, FE-SEM, "1H NMR, fluorescence spectroscopy techniques and DFT calculations. - Highlights: • Three electronically tuned sulfonamide-based probes (probes 1, 2, and 3) were developed for metal ion-sensing. • Probes 2 and 3 exhibited AIE behavior with increasing water-content. • Probes 2 and 3 displayed a selective fluorescence “OFF-ON“ behavior for Ga"3"+ detection with the LOD of 10 nM. • PET

  8. Feasibility of Real-Time Near-Infrared Fluorescence Tracer Imaging in Sentinel Node Biopsy for Oral Cavity Cancer Patients.

    Science.gov (United States)

    Christensen, Anders; Juhl, Karina; Charabi, Birgitte; Mortensen, Jann; Kiss, Katalin; Kjær, Andreas; von Buchwald, Christian

    2016-02-01

    Sentinel node biopsy (SNB) is an established method in oral squamous cell carcinoma (OSCC) for staging the cN0 neck and to select patients who will benefit from a neck dissection. Near-infrared fluorescence (NIRF) imaging has the potential to improve the SNB procedure by facilitating intraoperative visual identification of the sentinel lymph node (SN). The purpose of this study was to evaluate the feasibility of fluorescence tracer imaging for SN detection in conjunction with conventional radio-guided technique. Prospective study of patients with primary OSCC planned for tumor resection and SNB. Thirty patients were injected peritumorally with a bimodal tracer (ICG-99mTc-Nanocoll) followed by lymphoscintigraphy and SPECT/CT to define the SNs and their anatomic allocation preoperatively. SNs were detected intraoperatively with a hand-held gamma-probe and a hand-held NIRF camera. In 29 of 30 subjects (97%), all preoperatively defined SNs could be identified intraoperatively using a combination of radioactive and fluorescence guidance. A total of 94 SNs (mean 3, range 1-5) that were both radioactive and fluorescent ex vivo were harvested. Eleven of 94 SNs (12%) could only be identified in vivo using NIRF imaging, and the majority of those were located in level 1 close to the primary tumor. A combined fluorescent and radioactive tracer for SNB is feasible, and the additional use of NIRF imaging may improve the accuracy of SN identification in oral cancer patients. Intraoperative fluorescence guidance seems of particular value when SNs are located in close proximity to the injection site.

  9. A novel dog-bone oscillating AFM probe with thermal actuation and piezoresistive detection.

    Science.gov (United States)

    Xiong, Zhuang; Mairiaux, Estelle; Walter, Benjamin; Faucher, Marc; Buchaillot, Lionel; Legrand, Bernard

    2014-10-31

    In order to effectively increase the resonance frequency and the quality factor of atomic force microscope (AFM) probes, a novel oscillating probe based on a dog-bone shaped MEMS resonator was conceived, designed, fabricated and evaluated. The novel probe with 400 μm in length, 100 μm in width and 5 μm in thickness was enabled to feature MHz resonance frequencies with integrated thermal actuation and piezoresistive detection. Standard silicon micromachining was employed. Both electrical and optical measurements were carried out in air. The resonance frequency and the quality factor of the novel probe were measured to be 5.4 MHz and 4000 respectively, which are much higher than those (about several hundreds of kHz) of commonly used cantilever probes. The probe was mounted onto a commercial AFM set-up through a dedicated probe-holder and circuit board. Topographic images of patterned resist samples were obtained. It is expected that the resonance frequency and the measurement bandwidth of such probes will be further increased by a proper downscaling, thus leading to a significant increase in the scanning speed capability of AFM instruments.

  10. IVVS probe mechanical concept design

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Paolo, E-mail: paolo.rossi@enea.it; Neri, Carlo; De Collibus, Mario Ferri; Mugnaini, Giampiero; Pollastrone, Fabio; Crescenzi, Fabio

    2015-10-15

    Highlights: • ENEA designed, developed and tested a laser based In Vessel Viewing System (IVVS). • IVVS mechanical design has been revised from 2011 to 2013 to meet ITER requirements. • Main improvements are piezoceramic actuators and a step focus system. • Successful qualification activities validated the concept design for ITER environment. - Abstract: ENEA has been deeply involved in the design, development and testing of a laser based In Vessel Viewing System (IVVS) required for the inspection of ITER plasma-facing components. The IVVS probe shall be deployed into the vacuum vessel, providing high resolution images and metrology measurements to detect damages and possible erosion. ENEA already designed and manufactured an IVVS probe prototype based on a rad-hard concept and driven by commercial micro-step motors, which demonstrated satisfying viewing and metrology performances at room conditions. The probe sends a laser beam through a reflective rotating prism. By rotating the axes of the prism, the probe can scan all the environment points except those present in a shadow cone and the backscattered light signal is then processed to measure the intensity level (viewing) and the distance from the probe (metrology). During the last years, in order to meet all the ITER environmental conditions, such as high vacuum, gamma radiation lifetime dose up to 5 MGy, cumulative neutron fluence of about 2.3 × 10{sup 17} n/cm{sup 2}, temperature of 120 °C and magnetic field of 8 T, the probe mechanical design was significantly revised introducing a new actuating system based on piezo-ceramic actuators and improved with a new step focus system. The optical and mechanical schemes have been then modified and refined to meet also the geometrical constraints. The paper describes the mechanical concept design solutions adopted in order to fulfill IVVS probe functional performance requirements considering ITER working environment and geometrical constraints.

  11. Neutron and gamma probes: Their use in agronomy. Second edition

    International Nuclear Information System (INIS)

    2003-01-01

    Water is an essential requirement for life on the planet. It is often the single most limiting factor in crop and livestock production. Water is a scarce resource in many urban and rural environments worldwide. According to the FAO, the global demand for fresh water is doubling every 21 years. The quality of the finite water supplies is also under threat from industrial, agricultural and domestic sources of pollution. The majority of crops are grown under rain-fed conditions and adequate water supply is the main factor limiting crop production in semi-arid and sub-humid regions. On the other hand, currently 20% of the world's arable land is under irrigation providing 35 to 40% of all agricultural production. Irrigation mismanagement poses a serious threat to the environment through groundwater pollution and salinization. It is therefore, essential that water resources be used efficiently by regular monitoring of soil-water status in the unsaturated zone. The neutron depth probe, a nuclear-based technique, is utilized worldwide for this purpose. The neutron moisture gauge, since its introduction some 40 years ago, can now be considered a routine method in soil water studies. Many developments have since been introduced, in particular electronic components, which have significantly improved performance and expanded applications. Although the neutron scattering method is routinely utilised in many developed countries, its use is still limited in developing countries due to several factors. Neutron depth probes contain radioactive sources, which will present health and environmental hazards if a probe is improperly used, stored or disposed of. National and international legislation and regulations must be complied with. The strategic objective of the sub-program Soil and Water Management and Crop Nutrition of the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture is to develop and promote the adoption of nuclear-based technologies for optimising soil

  12. Prompt-gamma detection towards absorbed energy monitoring during hadrontherapy

    Energy Technology Data Exchange (ETDEWEB)

    Krimmer, J.; Balleyguier, L.; Dauvergne, D.; Mathez, H.; Pinto, M.; Testa, E.; Zoccarato, Y. [Institut de Physique Nucleaire de Lyon, Universite de Lyon, Universite de Lyon 1, IN2P3/CNRS, UMR 5822, F-69622 Villeurbanne cedex (France); Krimmer, J.; Freud, N.; L' etang, J.M. [Universite de Lyon, CREATIS, CNRS UMR 5220, Inserm U1044, INSA - Lyon, Universite Lyon 1, Centre Leon Berard (France); Herault, J.; Amblard, R.; Angellier, G. [Centre Antoine Lacassagne, Cyclotron Biomedical, 227 Avenue de la Lanterne, 06200 Nice (France)

    2015-07-01

    Hadrontherapy is an emerging technique which exploits the fact that a large quantity of the energy of the incident particles is deposited at the end of their flight path. This allows a conformation of the applied dose to the tumor volume and a simultaneous sparing of surrounding healthy tissue. A real-time control of the ion range during the treatment is possible via the detection of prompt secondary radiation (gamma rays or charged particles). Besides a monitoring of the ion range, the knowledge of the total energy absorbed inside the patient is also of importance for an improvement of the treatment quality. It has been shown that the ambient dose in a treatment room is correlated to the monitoring units, i.e. the number of protons of the beam delivery system. The present study consists in applying time-of-flight (TOF) information to identify prompt gamma-rays generated by interactions inside the patient which provides a direct information on the energy imparted. Results from test measurements will be given, which show that events generated in the nozzle and the target phantom can be discriminated. Furthermore, a standalone detection system is being developed which will be read out by a standard PC. The status of the developments for the corresponding electronics will be presented. (authors)

  13. Portal monitor incorporating smart probes

    International Nuclear Information System (INIS)

    Bartos, D.; Constantin, F.; Guta, T.

    2003-01-01

    Portal monitors are intended for detection of radioactive and special nuclear materials in vehicles, pedestrians, luggage, as well as for prevention of illegal traffic of radioactive sources. Monitors provide audio and visual alarms when radioactive and/or special nuclear materials are detected. They can be recommended to officers of customs, border guard and emergency services, civil defense, fire brigades, police and military departments or nuclear research or energetic facilities. The portal monitor developed by us consists in a portal frame, which sustains five intelligent probes having long plastic scintillator (0.5 liters each). The probes communicate, by serial transmission, with a Central Unit constructed on the basis of the 80552 microcontroller. This one manages the handshake, calculates the background, establishes the measuring time, starts and stops each measurement and makes all the other decisions. Sound signals and an infrared sensor monitor the passing through the portal and the measuring procedure. For each measurement the result is displayed on a LCD device contaminated/uncontaminated; for the contaminated case a loud and long sound signal is also issued. An RS 232 serial interface is provided in order to further developments or custom made devices. As a result, the portal monitor detects 1 μ Ci 137 Cs, spread all over a human body, in a 20 μR/h gamma background for a measuring time of 1.5 or 10 seconds giving a 99% confidence factor. (authors)

  14. An Amidochlorin-Based Colorimetric Fluorescent Probe for Selective Cu2+ Detection

    Directory of Open Access Journals (Sweden)

    Wenting Li

    2016-01-01

    Full Text Available The design and synthesis of selective and sensitive chemosensors for the quantification of environmentally and biologically important ionic species has attracted widespread attention. Amidochlorin p6 (ACP; an effective colorimetric and fluorescent probe for copper ions (Cu2+ in aqueous solution derived from methyl pheophorbide-a (MPa was designed and synthesized. A remarkable color change from pale yellow to blue was easily observed by the naked eye upon addition of Cu2+; and a fluorescence quenching was also determined. The research of fluorescent quenching of ACP-Cu2+ complexation showed the detection limit was 7.5 × 10−8 mol/L; which suggested that ACP can act as a high sensitive probe for Cu2+ and can be used to quantitatively detect low levels of Cu2+ in aqueous solution. In aqueous solution the probe exhibits excellent selectivity and sensitivity toward Cu2+ ions over other metal ions (M = Zn2+; Ni2+; Ba2+; Ag+; Co2+; Na+; K+; Mg2+; Cd2+; Pb2+; Mn2+; Fe3+; and Ca2+. The obvious change from pale yellow to blue upon the addition of Cu2+ could make it a suitable “naked eye” indicator for Cu2+.

  15. Gamma-ray boxes from axion-mediated dark matter

    International Nuclear Information System (INIS)

    Ibarra, Alejandro; Gehler, Sergio López; Pato, Miguel; Lee, Hyun Min; Park, Wan-Il

    2013-01-01

    We compute the gamma-ray output of axion-mediated dark matter and derive the corresponding constraints set by recent data. In such scenarios the dark matter candidate is a Dirac fermion that pair-annihilates into axions and/or scalars. Provided that the axion decays (at least partly) into photons, these models naturally give rise to a box-shaped gamma-ray spectrum that may present two distinct phenomenological behaviours: a narrow box, resembling a line at half the dark matter mass, or a wide box, spanning an extensive energy range up to the dark matter mass. Remarkably, we find that in both cases a sizable gamma-ray flux is predicted for a thermal relic without fine-tuning the model parameters nor invoking boost factors. This large output is in line with recent Fermi-LAT observations towards the galactic centre region and is on the verge of being excluded. We then make use of the Fermi-LAT and H.E.S.S. data to derive robust, model-independent upper limits on the dark matter annihilation cross section for the narrow and wide box scenarios. H.E.S.S. constraints, in particular, turn out to match the ones from Fermi-LAT at hundreds of GeV and extend to multi-TeV masses. Future Čerenkov telescopes will likely probe gamma-ray boxes from thermal dark matter relics in the whole multi-TeV range, a region hardly accessible to direct detection, collider searches and other indirect detection strategies

  16. Reliability of maximal isometric knee strength testing with modified hand-held dynamometry in patients awaiting total knee arthroplasty: useful in research and individual patient settings? A reliability study

    Directory of Open Access Journals (Sweden)

    Koblbauer Ian FH

    2011-10-01

    Full Text Available Abstract Background Patients undergoing total knee arthroplasty (TKA often experience strength deficits both pre- and post-operatively. As these deficits may have a direct impact on functional recovery, strength assessment should be performed in this patient population. For these assessments, reliable measurements should be used. This study aimed to determine the inter- and intrarater reliability of hand-held dynamometry (HHD in measuring isometric knee strength in patients awaiting TKA. Methods To determine interrater reliability, 32 patients (81.3% female were assessed by two examiners. Patients were assessed consecutively by both examiners on the same individual test dates. To determine intrarater reliability, a subgroup (n = 13 was again assessed by the examiners within four weeks of the initial testing procedure. Maximal isometric knee flexor and extensor strength were tested using a modified Citec hand-held dynamometer. Both the affected and unaffected knee were tested. Reliability was assessed using the Intraclass Correlation Coefficient (ICC. In addition, the Standard Error of Measurement (SEM and the Smallest Detectable Difference (SDD were used to determine reliability. Results In both the affected and unaffected knee, the inter- and intrarater reliability were good for knee flexors (ICC range 0.76-0.94 and excellent for knee extensors (ICC range 0.92-0.97. However, measurement error was high, displaying SDD ranges between 21.7% and 36.2% for interrater reliability and between 19.0% and 57.5% for intrarater reliability. Overall, measurement error was higher for the knee flexors than for the knee extensors. Conclusions Modified HHD appears to be a reliable strength measure, producing good to excellent ICC values for both inter- and intrarater reliability in a group of TKA patients. High SEM and SDD values, however, indicate high measurement error for individual measures. This study demonstrates that a modified HHD is appropriate to

  17. Investigation of electric quadrupole interaction in TiO2 by means of perturbed gamma-gamma angular correlation spectroscopy

    International Nuclear Information System (INIS)

    Martucci, Thiago; Ramos, Juliana Marques; Carbonari, Artur Wilson; Silva, Andreia S.; Saxena, Rajendra Narain

    2011-01-01

    TiO 2 has called attention in both basic research and technological applications as an energy converter in solar cells, photo catalyst for water purification, sunscreen material, drug detection, and other applications. In addition TiO 2 is a candidate for use in medical devices, food preparation surfaces, air conditioning filters and sanitary ware surfaces.TiO 2 has two crystalline phases: anatase and rutile. The structural properties and hyperfine interactions in TiO 2 were investigated by perturbed gamma-gamma angular correlation (PAC) spectroscopy using 111 In and 181 Hf as probe nuclei. The PAC spectroscopy provides information on crystalline and electronic structure at an atomic scale. In the present work, PAC measurements on TiO 2 were focused on the development of a methodology to prepare bulk samples, which have been characterized by conventional techniques such as x-ray diffraction, (XRD), scanning electron microscopy (SEM) and Energy Dispersive Spectroscopy (EDS). The samples were prepared by the sol gel Pechini method. The resulting powders were annealed at different temperatures in a tubular furnace under nitrogen atmosphere. The PAC measurements were carried out at room temperature in air. The occupation fraction of the probe nuclei reached 50% when the sample was annealed at 1373K and after measured at room temperature.In this case the frequency measured in site 1 is in agreement with that found in literature for substitutional titanium site in rutile structure when 111 In were used as probe nuclei. It was measured a frequency more closely to that was found in literature[7] for the case in which 181 Hf were used as probe nuclei when the sample annealed at 1373 K and measured at 973 K. (author)

  18. Detection of chromogranins A and B in endocrine tissues with radioactive and biotinylated oligonucleotide probes

    International Nuclear Information System (INIS)

    Lloyd, R.V.; Jin, L.; Fields, K.

    1990-01-01

    We analyzed the distribution of chromogranins A and B in normal and neoplastic endocrine tissues with secretory granules using 35 S-labeled and biotin-labeled oligonucleotide probes by in situ hybridization (ISH). Both radioactive and nonradioactive probes detected messenger RNAs (mRNAs) in frozen and paraffin tissue sections. Endocrine tissues with variable immunoreactivities for chromogranin A protein, such as small-cell lung carcinomas, neuroblastomas, insulinomas, and parathyroid adenomas, expressed the mRNA for chromogranins A and B in most cells. Some technical problems with the biotinylated probes included nonspecific nuclear staining and endogenous alkaline phosphatase, which was not completely abolished by levamisole pretreatment. A differential distribution of chromogranins A and B was seen in pituitary prolactinomas, which expressed abundant chromogranin B but not chromogranin A mRNAs, and in parathyroid adenomas, which expressed abundant chromogranin A but only small amounts of chromogranin B mRNAs. These results indicate that ISH can be used to detect chromogranins A and B in endocrine tissues with radioactive and biotinylated oligonucleotide probes and that the mRNAs for chromogranin A and B are demonstrable in some tumors even when the chromogranin proteins cannot be detected by immunohistochemistry

  19. Detection of chromogranins A and B in endocrine tissues with radioactive and biotinylated oligonucleotide probes

    Energy Technology Data Exchange (ETDEWEB)

    Lloyd, R.V.; Jin, L.; Fields, K. (Univ. of Michigan, Ann Arbor (USA))

    1990-01-01

    We analyzed the distribution of chromogranins A and B in normal and neoplastic endocrine tissues with secretory granules using {sup 35}S-labeled and biotin-labeled oligonucleotide probes by in situ hybridization (ISH). Both radioactive and nonradioactive probes detected messenger RNAs (mRNAs) in frozen and paraffin tissue sections. Endocrine tissues with variable immunoreactivities for chromogranin A protein, such as small-cell lung carcinomas, neuroblastomas, insulinomas, and parathyroid adenomas, expressed the mRNA for chromogranins A and B in most cells. Some technical problems with the biotinylated probes included nonspecific nuclear staining and endogenous alkaline phosphatase, which was not completely abolished by levamisole pretreatment. A differential distribution of chromogranins A and B was seen in pituitary prolactinomas, which expressed abundant chromogranin B but not chromogranin A mRNAs, and in parathyroid adenomas, which expressed abundant chromogranin A but only small amounts of chromogranin B mRNAs. These results indicate that ISH can be used to detect chromogranins A and B in endocrine tissues with radioactive and biotinylated oligonucleotide probes and that the mRNAs for chromogranin A and B are demonstrable in some tumors even when the chromogranin proteins cannot be detected by immunohistochemistry.

  20. Radioguided Surgery for Localization of Nonpalpable Breast Lesions A Mini-Review

    DEFF Research Database (Denmark)

    Langhans, Linnea; Klausen, Thomas Levin; Tvedskov, Tove Filtenborg

    2016-01-01

    by ultrasound a small titanium seed containing typically 1-10 MBq of radioactive iodine-125 is placed in the centre of the nonpalpable breast lesion. During the operation the seed is located with a hand-held gamma probe. To date, only few cohort studies exist on the feasibility of RSL, and the method has only...... of patients with insufficient resection margin. These patients require a reoperation. New methods in the field of radioguided surgery (RGS) have been developed including radioguided occult lesion localization (ROLL) and radioactive seed localization (RSL). Especially RSL is a very promising technique. Guided...

  1. An Optimized Set of Fluorescence In Situ Hybridization Probes for Detection of Pancreatobiliary Tract Cancer in Cytology Brush Samples.

    Science.gov (United States)

    Barr Fritcher, Emily G; Voss, Jesse S; Brankley, Shannon M; Campion, Michael B; Jenkins, Sarah M; Keeney, Matthew E; Henry, Michael R; Kerr, Sarah M; Chaiteerakij, Roongruedee; Pestova, Ekaterina V; Clayton, Amy C; Zhang, Jun; Roberts, Lewis R; Gores, Gregory J; Halling, Kevin C; Kipp, Benjamin R

    2015-12-01

    Pancreatobiliary cancer is detected by fluorescence in situ hybridization (FISH) of pancreatobiliary brush samples with UroVysion probes, originally designed to detect bladder cancer. We designed a set of new probes to detect pancreatobiliary cancer and compared its performance with that of UroVysion and routine cytology analysis. We tested a set of FISH probes on tumor tissues (cholangiocarcinoma or pancreatic carcinoma) and non-tumor tissues from 29 patients. We identified 4 probes that had high specificity for tumor vs non-tumor tissues; we called this set of probes pancreatobiliary FISH. We performed a retrospective analysis of brush samples from 272 patients who underwent endoscopic retrograde cholangiopancreatography for evaluation of malignancy at the Mayo Clinic; results were available from routine cytology and FISH with UroVysion probes. Archived residual specimens were retrieved and used to evaluate the pancreatobiliary FISH probes. Cutoff values for FISH with the pancreatobiliary probes were determined using 89 samples and validated in the remaining 183 samples. Clinical and pathologic evidence of malignancy in the pancreatobiliary tract within 2 years of brush sample collection was used as the standard; samples from patients without malignancies were used as negative controls. The validation cohort included 85 patients with malignancies (46.4%) and 114 patients with primary sclerosing cholangitis (62.3%). Samples containing cells above the cutoff for polysomy (copy number gain of ≥2 probes) were classified as positive in FISH with the UroVysion and pancreatobiliary probes. Multivariable logistic regression was used to estimate associations between clinical and pathology findings and results from FISH. The combination of FISH probes 1q21, 7p12, 8q24, and 9p21 identified cancer cells with 93% sensitivity and 100% specificity in pancreatobiliary tissue samples and were therefore included in the pancreatobiliary probe set. In the validation cohort of

  2. Lymph scintigraphy and pre- and intraoperative gamma probe measurements for localization of sentinel lymph nodes (SLN) in breast cancer; Lymphszintigraphie sowie prae- und intraoperative Sondenmessung zur Darstellung des Sentinel Lymph Node (SLN) beim Mammakarzinom

    Energy Technology Data Exchange (ETDEWEB)

    Brenner, W.; Czech, N.; Felde, U. zum; Kampen, W.U.; Henze, E. [Kiel Univ. (Germany). Klinik fuer Nuklearmedizin; Ostertag, H. [Kiel Univ. (Germany). Klinik fuer Gynaekologie und Geburtshilfe; Klutmann, S.; Bohuslavizki, K.H. [Universitaetskrankenhaus Eppendorf, Hamburg (Germany). Abt. fuer Nuklearmedizin; Luettges, J.; Sprenger, A. [Kiel Univ. (Germany). Inst. fuer Allgemeine und Pathologische Anatomie

    2000-05-01

    Aim of this study was to prove the clinical value of nuclear medicine procedures to detect the sentinel lymph node (SLN) for SLN biopsy. Methods: In 132 patients with breast cancer we performed lymph scintigraphy of the breast as well as both pre- and intraoperative gamma probe measurements correlating the results with the findings of histopathology. Results: SLN were detectable in 62 of 110 patients according to a sensitivity of 56% when scanning was performed only at 1-2 h p.i. while the sensitivity increased to 86% (19 of 22 pts.) if sequential images were acquired up to 2 h p.i. One or more SLN were identified by a handheld gamma probe transcutaneously prior to surgery in 96% (113 of 118 pts.) of the patients who showed up with no clinically suspected lymph node metastases. Intraoperatively, in additionally 2 patients the SLN could be found resulting in a sensitivity of 97% (115 of 118 pts.). In only 3 patients with clinically no tumor spread to axillary lymph nodes no SLN could be identified by the probe. Skip lesions, i.e. lymph node metastases in patients with tumorfree SLN, occurred in 2 cases: Due to SLN biopsy in these patients lymph node staging was false negative compared to conventional staging by means of axillary lymph node dissection. Conclusion: The results demonstrate a high preoperative detection rate of SLN in patients with breast cancer using lymph scintigraphy and gamma probe measurements. Thus, nuclear medicine is capable of providing the basic requirements for SLN biopsy in the daily routine. (orig.) [German] Ziel der vorliegenden Arbeit im Vorfeld einer geplanten Multicenterstudie zur Wertigkeit der Sentinel-Lymphknoten (SLN) Biopsie war, die Zuverlaessigkeit der SLN-Detektion mit nuklearmedizinischen Methoden im klinischen Routinebetrieb zu ueberpruefen. Methoden: Bei 132 Patientinnen mit stanzbioptisch gesichertem Mammakarzinom fuehrten wir eine Lymphszintigraphie der Brust sowie eine prae- und intraoperative Gammasondenmessung durch und

  3. Detection of Pathogenic Biofilms with Bacterial Amyloid Targeting Fluorescent Probe, CDy11

    DEFF Research Database (Denmark)

    Kim, Jun Young; Sahu, Srikanta; Yau, Yin Hoe

    2016-01-01

    Bacterial biofilms are responsible for a wide range of persistent infections. In the clinic, diagnosis of biofilm-associated infections relies heavily on culturing methods, which fail to detect nonculturable bacteria. Identification of novel fluorescent probes for biofilm imaging will greatly...... facilitate diagnosis of pathogenic bacterial infection. Herein, we report a novel fluorescent probe, CDy11 (compound of designation yellow 11), which targets amyloid in the Pseudomonas aeruginosa biofilm matrix through a diversity oriented fluorescent library approach (DOFLA). CDy11 was further demonstrated...

  4. Neutron interrogation system using high gamma ray signature to detect contraband special nuclear materials in cargo

    Science.gov (United States)

    Slaughter, Dennis R [Oakland, CA; Pohl, Bertram A [Berkeley, CA; Dougan, Arden D [San Ramon, CA; Bernstein, Adam [Palo Alto, CA; Prussin, Stanley G [Kensington, CA; Norman, Eric B [Oakland, CA

    2008-04-15

    A system for inspecting cargo for the presence of special nuclear material. The cargo is irradiated with neutrons. The neutrons produce fission products in the special nuclear material which generate gamma rays. The gamma rays are detecting indicating the presence of the special nuclear material.

  5. CaSO4: Dy + Teflon dosimetric pellets for X, beta and gamma radiation detection

    International Nuclear Information System (INIS)

    Campos, L.L.; Lima, M.F.

    1987-08-01

    CaSO 4 : Dy + TEFLON dosimetric pellets with high sensitivity and low cost for X, beta and gamma radiation monitoring were studied and developed by the Dosimetric Material Production Laboratory of the Radiological Protection Departament and are disposable for sale. The thickness of the pellets are suitable for X, beta and gamma radiation measurements. The dosimetric properties of these pellets were determined and presented in this work. The results show the usefulness of 0,20mm thick pellets for beta radiation monitoring and 0,80mm thick pellets for x and gamma radiation detection. (Author) [pt

  6. Observations of the highest energy gamma-rays from gamma-ray bursts

    International Nuclear Information System (INIS)

    Dingus, Brenda L.

    2001-01-01

    EGRET has extended the highest energy observations of gamma-ray bursts to GeV gamma rays. Such high energies imply the fireball that is radiating the gamma-rays has a bulk Lorentz factor of several hundred. However, EGRET only detected a few gamma-ray bursts. GLAST will likely detect several hundred bursts and may extend the maximum energy to a few 100 GeV. Meanwhile new ground based detectors with sensitivity to gamma-ray bursts are beginning operation, and one recently reported evidence for TeV emission from a burst

  7. Colorimetric detection of Cucumber green mottle mosaic virus using unmodified gold nanoparticles as colorimetric probes.

    Science.gov (United States)

    Wang, Lin; Liu, Zhanmin; Xia, Xueying; Yang, Cuiyun; Huang, Junyi; Wan, Sibao

    2017-05-01

    Cucumber green mottle mosaic virus (CGMMV)causes a severe mosaic symptom of watermelon and cucumber, and can be transmitted via infected cucumber seeds, leaves and soil. It remains a challenge to detect this virus to prevent its introduction and infection and spread in fields. For this purpose, a simple and sensitive label-free colorimetric detection method for CGMMV has been developed with unmodified gold nanoparticles (AuNPs) as colorimetric probes. The method is based on the finding that the presence of RT-PCR target products of CGMMV and species-specific probes results in color change of AuNPs from red to blue after NaCl induction. Normally, species-specific probes attach to the surface of AuNPs and thereby increasing their resistance to NaCl-induced aggregation. The concentration of sodium, probes in the reaction system and evaluation of specificity and sensitivity of a novel assay, visual detection of Cucumber green mottle mosaic virus using unmodified AuNPs has been carried out with simple preparation of samples in our study. Through this assay, as low as 30pg/μL of CGMMV RNA was thus detected visually, by the naked eye, without the need for any sophisticated, expensive instrumentation and biochemical reagents. The specificity was 100% and exhibited good reproducibility in our assays. The results note that this assay is highly species-specific, simple, low-cost, and visual for easy detection of CGMMV in plant tissues. Therefore, visual assay is a potentially useful tool for middle or small-scales corporations and entry-exit inspection and quarantine bureau to detect CGMMV in cucumber seeds or plant tissues. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. In situ prompt gamma-ray activation analysis of water pollutants using a shallow 252Cf-HPGe probe

    International Nuclear Information System (INIS)

    Chung Chien; Tseng Tzucheng

    1988-01-01

    A shallow 252 Cf-HPGe probe used for in situ prompt γ-ray activation of water pollutants is described. A 2.7 μg 252 Cf neutron source and a 10% HPGe detector are inserted into a waterproof stainless steel probe, which is designed to be submerged and recovered in field operation. A laboratory test is performed to obtain the neutron flux distribution and prompt γ-ray contribution to the HPGe detector counts from around the submerged probe. The concentrations of toxic cadmium and chlorine in water are determined in the prompt γ-ray spectrum. The detection limit of industrial pollutants and some improvements of the current design are discussed. (orig.)

  9. A portable cadmium telluride multidetector probe for cardiac function monitoring

    CERN Document Server

    Arntz, Y; Dumitresco, B; Eclancher, B; Prat, V

    1999-01-01

    A new nuclear stethoscope based on a matrix of small CdTe semiconductor detectors has been developed for studying the cardiac performance by gamma ventriculography at the equilibrium, in rest and stress conditions, in the early and recovery phases of the coronary disease and to follow the long-term therapy. The light-weight probe consists of an array of 64 detectors 5x5x2 mm grouped in 16 independent units in a lead shielded aluminum box including 16 preamplifiers. The probe is connected to an electronic box containing DC power supply, 16 channel amplifiers, discriminators and counters, two analog-triggering ECG channels, and interface to a PC. The left ventricle activity is, preferentially, detected by using a low-resolution matching convergent collimator. A physical evaluation of the probe has been performed, both with static tests and dynamically with a hydraulic home-built model of beating heart ventricle paced by a rhythm simulator. The sum of the 16 detectors activity provided a radiocardiogram (RCG) wh...

  10. Design of a versatile detector for the detection of charged particles, neutrons and gamma rays. Neutron interaction with the matter

    International Nuclear Information System (INIS)

    Perez P, J.J.

    1991-01-01

    The Fostron detector detects charged particles, neutrons and gamma rays with a reasonable discrimination power. Because the typical detectors for neutrons present a great uncertainty in the detection, this work was focused mainly to the neutron detection in presence of gamma radiation. Also there are mentioned the advantages and disadvantages of the Fostron detector

  11. The use of {sup 99m}Tc-Al{sub 2}O{sub 3} for detection of sentinel lymph nodes in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Sinilkin, I., E-mail: sinilkinig@oncology.tomsk.ru; Chernov, V.; Medvedeva, A.; Zeltchan, R. [Tomsk Cancer Research Institute, Tomsk, 634050 (Russian Federation); Tomsk Polytechnic University, Tomsk, 634050 (Russian Federation); Slonimskaya, E.; Doroshenko, A. [Tomsk Cancer Research Institute, Tomsk, 634050 (Russian Federation); Varlamova, N.; Skuridin, V. [Tomsk Polytechnic University, Tomsk, 634050 (Russian Federation)

    2016-08-02

    Purpose: to study the feasibility of using the new radiopharmaceutical based on the technetium-99m-labeled gamma-alumina for identification of sentinel lymph nodes (SLNs) in breast cancer patients. The study included two groups of breast cancer patients who underwent single photon emission computed tomography (SPECT) and intraoperaive gamma probe identification of sentinel lymph nodes (SLNs). To identify SLNs, the day before surgery Group I patients (n = 34) were injected with radioactive {sup 99m}Tc-Al{sub 2}O{sub 3}, and Group II patients (n = 30) received {sup 99m}Tc-labeled phytate colloid. A total of 37 SLNs were detected in Group I patients. The number of identified SLNs per patient ranged from 1 to 2 (the average number of identified SLNs was 1.08). Axillary lymph nodes were the most common site of SLN localization. 18 hours after {sup 99m}Tc-Al{sub 2}O{sub 3} injection, the percentage of its accumulation in the SLN was 7–11% (of the counts in the injection site) by SPECT and 17–31% by gamma probe detection. In Group II SLNs were detected in 27 patients. 18 hours after injection of the phytate colloid the percentage of its accumulation in the SLN was 1.5–2% out of the counts in the injection site by SPECT and 4–7% by gamma probe. The new radiopharmaceutical based on the {sup 99m}Tc-Al{sub 2}O{sub 3} demonstrates high accumulation in SLNs without redistribution through the entire lymphatic basin. The sensitivity and specificity of {sup 99m}Tc-Al{sub 2}O{sub 3} were 100% for both SPECT and intraoperative gamma probe identification.

  12. Application of the similitude principle to gamma-gamma density measurements; Application du principe de similitude a la mesure gamma-gamma de densite

    Energy Technology Data Exchange (ETDEWEB)

    Czubek, J A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires. Departement d' Electronique Generale, Service d' Electronique Industrielle; Institut de Recherches Nucleaires, Dep. VI, Cracow (Poland)

    1966-07-01

    The work presented here deals with the problem of the application of the similitude principle to rock density measurements by the gamma-gamma method. A formula is presented which makes it possible to transform results of gamma-gamma measurements carried out on models in order to make them suitable for comparison with results obtained under actual field conditions. Both the space coordinates and the densities are transformed. This transformation makes it possible to obtain a calibration curve as a function of the density for a gamma-gamma probe using only a single model of given density. The influence has also been studied of the chemical composition on the results obtained from gamma-gamma measurements. A method has been developed for estimating the equivalent Z parameter of the medium; the possibility of completely eliminating the influence of the chemical composition of the medium on the measurement results has been studied. (author) [French] L'etude presentee ci-dessous traite le probleme de l'application du principe de similitude aux mesures de densite des roches par la methode gamma-gamma. Nous indiquons une formule qui permet de transformer les resultats des mesures gamma-gamma effectuees sur les modeles pour les comparer aux resultats obtenus dans les conditions reelles sur le terrain. On transforme les coordonnees spatiales ainsi que les densites. Cette transformation donne la possibilite d'obtenir une courbe d'etalonnage (en fonction de la densite) pour une sonde gamma-gamma en utilisant un seul modele de densite donnee. On a etudie aussi l'influence de la composition chimique sur les resultats obtenus des mesures gamma-gamma. On a etabli une methode d'estimation du parametre Z equivalent du milieu, ainsi que la possibilite d'eliminer completement l'influence de la composition chimique du milieu sur les resultats des mesures de densite. (auteur)

  13. Effects of gamma irradiation on food contact polyethylene, polypropylene and polystyrene: additives and other chemicals

    International Nuclear Information System (INIS)

    Kawamura, Yoko; Sayama, Kayo; Yamada, Takashi

    2000-01-01

    The effects of gamma irradiation on additives, oligomers, and other chemicals in food contact polyethylene, polypropylene and polystyrene were investigated. Polyethylene and polypropylene products contained several antioxidants, lubricants and plasticizers. After gamma irradiation, the contents of all the antioxidants significantly decreased. Irgafos 168 disappeared the fastest. Lubricants and plasticizers decreased to some extent or not at all. 2,4-Di-tert-butylphenol was detected not only after irradiation but also before irradiation, and 1,3-di-tert-butylbenzene and 2,6-di-tert-butyl-1,4-benzoquinone were detected only after irradiation. They were presumed to be degradation products of the irradiation, though the former should be also a degradation product of the manufacturing process. On the other hand, the polystyrene products contained styrene dimers and trimers and their contents did not change after the gamma irradiation. (author)

  14. [A new class of exciplex-formed probe detect of specific sequence DNA].

    Science.gov (United States)

    Li, Qing-Yong; Zu, Yuan-Gang; Lü, Hong-Yan; Wang, Li-Min

    2009-07-01

    The present research was to develop the exciplex-based fluorescence detection of DNA. A SNP-containing region of cytochrome P450 2C9 DNA systems was evaluated to define some of the structural and associated requirement of this new class of exciplex-formed probe, and a 24-base target was selected which contains single-nucleotide polymorphisms (SNP) in genes coding for cytochrome P450. The two probes were all 12-base to give coverage of a 24-base target region to ensure specificity within the human genome. Exciplex partners used in this study were prepared using analogous phosphoramide attachment to the 3'- or 5'-phosphate group of the appropriate oligonucleotide probes. The target effectively assembled its own detector by hybridization from components which were non-fluorescent at the detection wavelength, leading to the huge improvement in terms of decreased background. This research provides details of the effects of different partner, position of partners and different excitation wavelengths for the split-oligonucleotide probe system for exciplex-based fluorescence detection of DNA. This study demonstrates that the emission intensity of the excimer formed by new pyrene derivative is the highest in these excimer and exciplex, and the excimer is easy to be formed and not sensitive to the position of partners. However the exciplex formed by the new pyrene derivative and naphthalene emitted strongly at -505 nm with large Stokes shifts (120-130 nm), and the monomer emission at 390 and 410 nm is nearly zero. Excitation wavelength of 400 nm is the best for I(e505)/I(m410) (exciplex emission at 505 nm/monomer emission at 410 nm) of the exciplex. This method features lower background and high sensitivity. Moreover the exciplex is sensitive to the steric factor, different position of partners and microenvironment, so this exciplex system is promising and could be tried to identify the SNP genes.

  15. Neutron detection in a high gamma-ray background with EJ-301 and EJ-309 liquid scintillators

    International Nuclear Information System (INIS)

    Stevanato, L.; Cester, D.; Nebbia, G.; Viesti, G.

    2012-01-01

    Using a fast digitizer, the neutron–gamma discrimination capability of the new liquid scintillator EJ-309 is compared with that obtained using standard EJ-301. Moreover the capability of both the scintillation detectors to identify a weak neutron source in a high gamma-ray background is demonstrated. The probability of neutron detection is PD=95% at 95% confidence level for a gamma-ray background corresponding to a dose rate of 100 μSv/h.

  16. In Situ Detection of MicroRNA Expression with RNAscope Probes.

    Science.gov (United States)

    Yin, Viravuth P

    2018-01-01

    Elucidating the spatial resolution of gene transcripts provides important insight into potential gene function. MicroRNAs are short, singled-stranded noncoding RNAs that control gene expression through base-pair complementarity with target mRNAs in the 3' untranslated region (UTR) and inhibiting protein expression. However, given their small size of ~22- to 24-nt and low expression levels, standard in situ hybridization detection methods are not amendable for microRNA spatial resolution. Here, I describe a technique that employs RNAscope probe design and propriety amplification technology that provides simultaneous single molecule detection of individual microRNA and its target gene. This method allows for rapid and sensitive detection of noncoding RNA transcripts in frozen tissue sections.

  17. Radioimmunoguided surgery using the monoclonal antibody B72.3 in colorectal tumors

    International Nuclear Information System (INIS)

    Sickle-Santanello, B.J.; O'Dwyer, P.J.; Mojzisik, C.

    1987-01-01

    The authors have developed a hand-held gamma-detecting probe (GDP) for intraoperative use that improves the sensitivity of external radioimmunodetection. Radiolabeled monoclonal antibody (MAb) B72.3 was injected in six patients with primary colorectal cancer and 31 patients with recurrent colorectal cancer an average of 16 days preoperatively. The GDP localized the MAb B72.3 in 83 percent of sites. The technique, known as a radioimmunoguided surgery (RIGS) system did not alter the surgical procedure in patients with primary colorectal cancer but did alter the approach in 26 percent (8/31) of patients with recurrent colorectal cancer. Two patients avoided unnecessary liver resections and two underwent extraabdominal approaches to document their disease. The RIGS system may influence the short-term morbidity and mortality of surgery for colorectal cancer. Larger series and longer follow-up are needed to determine whether the RIGS system confers a survival advantage to the patient with colorectal cancer

  18. Clinical Applications of Phage-Derived sFvs and sFv Fusion Proteins

    Directory of Open Access Journals (Sweden)

    K. A. Chester

    2000-01-01

    Full Text Available Single chain Fv antibodies (sFvs have been produced from filamentous bacteriophage libraries obtained from immunised mice. MFE-23, the most characterised of these sFvs, is reactive with carcinoembryonic antigen (CEA, a glycoprotein that is highly expressed in colorectal adenocarcinomas. MFE-23 has been expressed in bacteria and purified in our laboratory for two clinical trials; a gamma camera imaging trial using 123I-MFE-23 and a radioimmunoguided surgery trial using 125I-MFE-23, where tumour deposits are detected by a hand-held probe during surgery. Both these trials show MFE-23 is safe and effective in localising tumour deposits in patients with cancer. We are now developing fusion proteins which use MFE-23 to deliver a therapeutic moiety; MFE-23::CPG2 targets the enzyme carboxypeptidase G2 (CPG2 for use in the ADEPT (antibody directed enzyme prodrug therapy system and MFE::TNFα aims to reduce sequestration and increase tumor concentrations of systemically administered TNFα.

  19. Organophosphate Nerve Agent Detection with Europium Complexes

    Directory of Open Access Journals (Sweden)

    Jake R. Schwierking

    2004-01-01

    Full Text Available We explore the detection of paraoxon, a model compound for nonvolatile organophosphate nerve agents such as VX. The detection utilizes europium complexes with 1,10 phenanthroline and thenoyltrifluoroacetone as sensitizing ligands. Both europium luminescence quenching and luminescence enhancement modalities are involved in the detection, which is simple, rapid, and sensitive. It is adaptable as well to the more volatile fluorophosphate nerve agents. It involves nothing more than visual luminescence observation under sample illumination by an ordinary hand-held ultraviolet lamp.

  20. A portable medium-resolution gamma-ray spectrometer and analysis software

    Energy Technology Data Exchange (ETDEWEB)

    Lavietes, A.D.; McQuaid, J.H.; Ruhter, W.D.; Buckley, W.M.; Clark, D-L. [Lawrence Livermore National Lab., CA (United States); Paulus, T.J. [EG and G ORTEC, Oak Ridge, TN (United States)

    1996-07-01

    There is a strong need for portable radiometric instrumentation that can both accurately confirm the presence of nuclear materials and allow isotopic analysis of radionuclides in the field. To fulfill this need the Safeguards Technology Program at LLNL has developed a hand-held, non-cryogenic, low-power gamma-ray and x-ray measurements and analysis instrument that can both search for and then accurately verify the presence of nuclear materials. We will report on the use of cadmium zinc telluride (CZT) detectors, detector electronics, and the new field-portable instrument being developed. We will also describe the isotopic analysis that allows enrichment measurements to be made accurately in the field. These systems provide capability for safeguards inspection and verification applications and could find application in counter-smuggling operations.