WorldWideScience

Sample records for hand-held digital fundus

  1. Digital knowledge in the coat pocket - hand-held personal digital assistants in radiology

    International Nuclear Information System (INIS)

    Niehues, S.M.; Froehlich, M.; Felix, R.; Lemke, A.J.

    2004-01-01

    The personal digital assistant (PDA) enables the independent access to large data in a pocket-sized format. The applications for hand-held computers are growing steadily and can support almost any kind of problem. An overview of the available hardware and software is provided and evaluated. Furthermore, the use of the PDA in the clinical daily routine is described. In view of the numerous software programs available in radiology, the range of software solutions for radiologists is presented. Despite the high acquisition cost, the PDA has already become the digital assistant for the radiologist. After a short time of getting used to the PDA, nobody wants to miss it at work or at home. New technical features and available software programs will continuously increase the integration of the PDA into the medical workflow in the near future. (orig.)

  2. Screening for diabetic retinopathy in rural area using single-field, digital fundus images.

    Science.gov (United States)

    Ruamviboonsuk, Paisan; Wongcumchang, Nattapon; Surawongsin, Pattamaporn; Panyawatananukul, Ekchai; Tiensuwan, Montip

    2005-02-01

    To evaluate the practicability of using single-field, 2.3 million-pixel, digital fundus images for screening of diabetic retinopathy in rural areas. All diabetic patients who regularly attended the diabetic clinic at Kabcheang Community Hospital, located at 15 kilometers from the Thailand-Cambodia border, were appointed to the hospital for a 3-day diabetic retinopathy screening programme. The fundi of all patients were captured in single-field, 45 degrees, 2.3 million-pixel images using nonmydriatic digital fundus camera and then sent to a reading center in Bangkok. The fundi were also examined through dilated pupils by a retinal specialist at this hospital. The grading of diabetic retinopathy from two methods was compared for an exact agreement. The average duration of single digital fundus image capture was 2 minutes. The average file size of each image was 750 kilobytes. The average duration of single image transmission to a reading center in Bangkok via satellite was 3 minutes; via a conventional telephone line was 8 minutes. Of all 150 patients, 130 were assessed for an agreement between dilated fundus examination and digital fundus images in diagnosis of diabetic retinopathy. The exact agreement was 0.87, the weighted kappa statistics was 0.74. The sensitivity of digital fundus images in detecting diabetic retinopathy was 80%, the specificity was 96%. For diabetic macular edema the exact agreement was 0.97, the weighted kappa was 0.43, the sensitivity was 43%, and the specificity was 100%. The image capture of the nonmydriatic digital fundus camera is suitable for screening of diabetic retinopathy and single-field digital fundus images are potentially acceptable tools for the screening. The real-time image transmission via telephone lines to remote reading center, however, may not be practical for routine diabetic retinopathy screening in rural areas.

  3. The sensitivity and specificity of one field non-mydriatic digital fundus photography for DR screening

    Directory of Open Access Journals (Sweden)

    Bin-Bin Li

    2013-07-01

    Full Text Available AIM:To evaluate the sensitivity and specificity of one-field non-mydriatic digital fundus photography and direct ophthalmoscopy for diabetic retinopathy(DRscreening, compared with fundus fluorescein angiography( FFA .METHODS:All 93 patients of type 1 or 2 diabetic who have underwent one-field non-mydriatic digital fundus photography, and direct ophthalmoscopy with dilation of their pupils, and FFA by ophthalmologists. The sensitivity and specificity of one-field non-mydriatic digital fundus photography and direct ophthalmoscopy were calculated respectively, compared with FFA.RESULTS: The sensitivity and specificity of one-field non-mydriatic digital fundus photography for detection of any DR were 80.4% and 94.7%; The sensitivity and specificity of direct ophthalmoscopy for detection of any DR were 64.2% and 84.2%; After the standard for referable DR being lowered down to the moderate non-proliferative diabetic retinopathy(M-NPDR, the sensitivity and specificity of non-mydriatic digital fundus photography for detection were 88.9% and 98.4%, the sensitivity and specificity of direct ophthalmoscopy for detection were 71.5% and 96.7%.CONCLUSION: One-field non-mydriatic digital fundus photography is an effective method for DR screening.

  4. Analysis of Information Remaining on Hand Held Devices Offered for Sale on the Second Hand Market

    Directory of Open Access Journals (Sweden)

    Andy Jones

    2008-06-01

    Full Text Available The ownership and use of mobile phones, Personal Digital Assistants and other hand held devices is now ubiquitous both for home and business use. The majority of these devices have a high initial cost, a relatively short period before they become obsolescent and a relatively low second hand value.  As a result of this, when the devices are replaced, there are indications that they tend to be discarded.  As technology has continued to develop, it has led to an increasing diversity in the number and type of devices that are available, and the processing power and the storage capacity of the digital storage in the device. All organisations, whether in the public or private sector increasingly use hand held devices that contain digital media for the storage of information relating to their business, their employees or their customers. Similarly, individual private users increasingly use hand held devices containing digital media for the storage of information relating to their private lives.The research revealed that a significant number of organisations and private users are ignorant or misinformed about the volume and type of information that is stored on the hand held devices and the media on which it is stored.  It is apparent that they have either not considered, or are unaware of, the potential impact of this information becoming available to their competitors or those with criminal intent.This main purpose of this study was to gain an understanding of the volume and type of information that may remain on hand held devices that are offered for sale on the second hand market.  A second aim of the research was to determine the level of damage that could, potentially be caused, if the information that remains on the devices fell into the wrong hands.  The study examined a number of hand held devices that had been obtained from sources in the UK and Australia that ranged from internet auction sites, to private sales and commercial

  5. X-ray film digitization using a personal computer and hand-held scanner: a simple technique for storing images

    International Nuclear Information System (INIS)

    Munoz-Nunez, C. F.; Lloret-Alcaniz, A.

    1998-01-01

    To develop a simple, low-cost technique for the digitization of X-ray films for personal use. A 66-MHz 486 PC with 8 MB of RAM, a Logitech ScanMan 256 hand-held scanner and a standard negatoscope with the power source converted to direct current. Although the system was originally designed for the digitization of mammographies, it has also been used with computed tomography, magnetic resonance, digital angiography and ultrasonographic images, as well as plain X-rays. After a minimal training period, the system digitized X-ray films easily and rapidly. Although the scanning values vary depending on the type of image to be digitized, an input spatial resolution of 200 dpi and a contrast resolution of 256 levels of gray are generally adequate. Of the storage formats tested, JPEG presented the best quality/image size ratio. A simple, low-cost technique has been developed for the digitization of X-ray films. This technique enables the storage of images in a digital format, thus facilitating their presentation and transmission. (Author) 9 refs

  6. Hand-held medical robots.

    Science.gov (United States)

    Payne, Christopher J; Yang, Guang-Zhong

    2014-08-01

    Medical robots have evolved from autonomous systems to tele-operated platforms and mechanically-grounded, cooperatively-controlled robots. Whilst these approaches have seen both commercial and clinical success, uptake of these robots remains moderate because of their high cost, large physical footprint and long setup times. More recently, researchers have moved toward developing hand-held robots that are completely ungrounded and manipulated by surgeons in free space, in a similar manner to how conventional instruments are handled. These devices provide specific functions that assist the surgeon in accomplishing tasks that are otherwise challenging with manual manipulation. Hand-held robots have the advantages of being compact and easily integrated into the normal surgical workflow since there is typically little or no setup time. Hand-held devices can also have a significantly reduced cost to healthcare providers as they do not necessitate the complex, multi degree-of-freedom linkages that grounded robots require. However, the development of such devices is faced with many technical challenges, including miniaturization, cost and sterility, control stability, inertial and gravity compensation and robust instrument tracking. This review presents the emerging technical trends in hand-held medical robots and future development opportunities for promoting their wider clinical uptake.

  7. Automatic Microaneurysm Detection and Characterization Through Digital Color Fundus Images

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Charles; Veras, Rodrigo; Ramalho, Geraldo; Medeiros, Fatima; Ushizima, Daniela

    2008-08-29

    Ocular fundus images can provide information about retinal, ophthalmic, and even systemic diseases such as diabetes. Microaneurysms (MAs) are the earliest sign of Diabetic Retinopathy, a frequently observed complication in both type 1 and type 2 diabetes. Robust detection of MAs in digital color fundus images is critical in the development of automated screening systems for this kind of disease. Automatic grading of these images is being considered by health boards so that the human grading task is reduced. In this paper we describe segmentation and the feature extraction methods for candidate MAs detection.We show that the candidate MAs detected with the methodology have been successfully classified by a MLP neural network (correct classification of 84percent).

  8. 30 CFR 56.12033 - Hand-held electric tools.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL....12033 Hand-held electric tools. Hand-held electric tools shall not be operated at high potential...

  9. 30 CFR 57.12033 - Hand-held electric tools.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...

  10. A hand-held beta imaging probe for FDG.

    Science.gov (United States)

    Singh, Bipin; Stack, Brendan C; Thacker, Samta; Gaysinskiy, Valeriy; Bartel, Twyla; Lowe, Val; Cool, Steven; Entine, Gerald; Nagarkar, Vivek

    2013-04-01

    Advances in radiopharmaceuticals and clinical understanding have escalated the use of intraoperative gamma probes in surgery. However, most probes on the market are non-imaging gamma probes that suffer from the lack of ancillary information of the surveyed tissue area. We have developed a novel, hand-held digital Imaging Beta Probe™ (IBP™) to be used in surgery in conjunction with beta-emitting radiopharmaceuticals such as (18)FDG, (131)I and (32)P for real-time imaging of a surveyed area with higher spatial resolution and sensitivity and greater convenience than existing instruments. We describe the design and validation of a hand-held beta probe intended to be used as a visual mapping device to locate and confirm excision of (18)FDG-avid primary tumors and metastases in an animal model. We have demonstrated a device which can generate beta images from (18)FDG avid lesions in an animal model. It is feasible to image beta irradiation in animal models of cancer given (18)FDG. This technology may be applied to clinical mapping of tumors and/or their metastases in the operating room. Visual image depiction of malignancy may aid the surgeon in localization and excision of lesions of interest.

  11. Integrating a Hand Held computer and Stethoscope into a Fetal Monitor

    Science.gov (United States)

    Ahmad Soltani, Mitra

    2009-01-01

    This article presents procedures for modifying a hand held computer or personal digital assistant (PDA) into a versatile device functioning as an electronic stethoscope for fetal monitoring. Along with functioning as an electronic stethoscope, a PDA can provide a useful information source for a medical trainee. Feedback from medical students, residents and interns suggests the device is well accepted by medical trainees. PMID:20165517

  12. Image quality characteristics of a novel colour scanning digital ophthalmoscope (SDO) compared with fundus photography.

    Science.gov (United States)

    Strauss, Rupert W; Krieglstein, Tina R; Priglinger, Siegfried G; Reis, Werner; Ulbig, Michael W; Kampik, Anselm; Neubauer, Aljoscha S

    2007-11-01

    To establish a set of quality parameters for grading image quality and apply those to evaluate the fundus image quality obtained by a new scanning digital ophthalmoscope (SDO) compared with standard slide photography. On visual analogue scales a total of eight image characteristics were defined: overall quality, contrast, colour brilliance, focus (sharpness), resolution and details, noise, artefacts and validity of clinical assessment. Grading was repeated after 4 months to assess repeatability. Fundus images of 23 patients imaged digitally by SDO and by Zeiss 450FF fundus camera using Kodak film were graded side-by-side by three graders. Lens opacity was quantified with the Interzeag Lens Opacity Meter 701. For all of the eight scales of image quality, good repeatability within the graders (mean Kendall's W 0.69) was obtained after 4 months. Inter-grader agreement ranged between 0.31 and 0.66. Despite the SDO's limited nominal image resolution of 720 x 576 pixels, the Zeiss FF 450 camera performed better in only two of the subscales - noise (p = 0.001) and artefacts (p = 0.01). Lens opacities significantly influenced only the two subscales 'resolution' and 'details', which deteriorated with increasing media opacities for both imaging systems. Distinct scales to grade image characteristics of different origin were developed and validated. Overall SDO digital imaging was found to provide fundus pictures of a similarly high level of quality as expert photography on slides.

  13. Comparison of a digital and an optical analogue hand-held refractometer for the measurement of canine urine specific gravity.

    Science.gov (United States)

    Paris, J K; Bennett, A D; Dodkin, S J; Gunn-Moore, D A

    2012-05-05

    Urine specific gravity (USG) is used clinically as a measure of urine concentration, and is routinely assessed by refractometry. A comparison between optical analogue and digital refractometers for evaluation of canine urine has not been reported. The aim of this study was to compare a digital and an optical analogue hand-held refractometer for the measurement of canine USG, and to assess correlation with urine osmolality. Prospective study. Free-catch urine samples were collected from 285 hospitalised adult dogs, and paired USG readings were obtained with a digital and an optical analogue refractometer. In 50 dogs, urine osmolality was also measured using a freezing point depression osmometer. There was a small but statistically significant difference between the two refractometers (P<0.001), with the optical analogue refractometer reading higher than the digital refractometer (mean difference 0.0006, sd 0.0012). Paired refractometer measurements varied by <0.002 in 91.5 per cent of cases. The optical analogue and digital refractometer readings showed excellent correlation with osmolality (r=0.980 and r=0.977, respectively, P<0.001 in both cases). Despite statistical significance, the difference between the two refractometers is unlikely to be clinically significant. Both instruments provide an accurate assessment of USG in dogs.

  14. Retinopathy online challenge: automatic detection of microaneurysms in digital color fundus photographs.

    NARCIS (Netherlands)

    Niemeijer, M.; Ginneken, B. van; Cree, M.J.; Mizutani, A.; Quellec, G.; Sanchez, C.I.; Zhang, B.; Hornero, R.; Lamard, M.; Muramatsu, C.; Wu, X.; Cazuguel, G.; You, J.; Mayo, A.; Li, Q.; Hatanaka, Y.; Cochener, B.; Roux, C.; Karray, F.; Garcia, M.; Fujita, H.; Abramoff, M.D.

    2010-01-01

    The detection of microaneurysms in digital color fundus photographs is a critical first step in automated screening for diabetic retinopathy (DR), a common complication of diabetes. To accomplish this detection numerous methods have been published in the past but none of these was compared with each

  15. Diabetic Retinopathy Screening Ratio Is Improved When Using a Digital, Nonmydriatic Fundus Camera Onsite in a Diabetes Outpatient Clinic

    Directory of Open Access Journals (Sweden)

    Pia Roser

    2016-01-01

    Full Text Available Objective. To evaluate the effect of onsite screening with a nonmydriatic, digital fundus camera for diabetic retinopathy (DR at a diabetes outpatient clinic. Research Design and Methods. This cross-sectional study included 502 patients, 112 with type 1 and 390 with type 2 diabetes. Patients attended screenings for microvascular complications, including diabetic nephropathy (DN, diabetic polyneuropathy (DP, and DR. Single-field retinal imaging with a digital, nonmydriatic fundus camera was used to assess DR. Prevalence and incidence of microvascular complications were analyzed and the ratio of newly diagnosed to preexisting complications for all entities was calculated in order to differentiate natural progress from missed DRs. Results. For both types of diabetes, prevalence of DR was 25.0% (n=126 and incidence 6.4% (n=32 (T1DM versus T2DM: prevalence: 35.7% versus 22.1%, incidence 5.4% versus 6.7%. 25.4% of all DRs were newly diagnosed. Furthermore, the ratio of newly diagnosed to preexisting DR was higher than those for DN (p=0.12 and DP (p=0.03 representing at least 13 patients with missed DR. Conclusions. The results indicate that implementing nonmydriatic, digital fundus imaging in a diabetes outpatient clinic can contribute to improved early diagnosis of diabetic retinopathy.

  16. Driver hand-held cellular phone use: a four-year analysis.

    Science.gov (United States)

    Eby, David W; Vivoda, Jonathon M; St Louis, Renée M

    2006-01-01

    The use of hand-held cellular (mobile) phones while driving has stirred more debate, passion, and research than perhaps any other traffic safety issue in the past several years. There is ample research showing that the use of either hand-held or hands-free cellular phones can lead to unsafe driving patterns. Whether or not these performance deficits increase the risk of crash is difficult to establish, but recent studies are beginning to suggest that cellular phone use elevates crash risk. The purpose of this study was to assess changes in the rate of hand-held cellular phone use by motor-vehicle drivers on a statewide level in Michigan. This study presents the results of 13 statewide surveys of cellular phone use over a 4-year period. Hand-held cellular phone use data were collected through direct observation while vehicles were stopped at intersections and freeway exit ramps. Data were weighted to be representative of all drivers traveling during daylight hours in Michigan. The study found that driver hand-held cellular phone use has more than doubled between 2001 and 2005, from 2.7% to 5.8%. This change represents an average increase of 0.78 percentage points per year. The 5.8% use rate observed in 2005 means that at any given daylight hour, around 36,550 drivers were conversing on cellular phones while driving on Michigan roadways. The trend line fitted to these data predicts that by the year 2010, driver hand-held cellular phone use will be around 8.6%, or 55,000 drivers at any given daylight hour. These results make it clear that cellular phone use while driving will continue to be an important traffic safety issue, and highlight the importance of continued attempts to generate new ways of alleviating this potential hazard.

  17. Optic Disc Detection from Fundus Photography via Best-Buddies Similarity

    Directory of Open Access Journals (Sweden)

    Kangning Hou

    2018-05-01

    Full Text Available Robust and effective optic disc (OD detection is a necessary processing step in the research work of the automatic analysis of fundus images. In this paper, we propose a novel and robust method for the automated detection of ODs from fundus photographs. It is essentially carried out by performing template matching using the Best-Buddies Similarity (BBS measure between the hand-marked OD region and the small parts of target images. For well characterizing the local spatial information of fundus images, a gradient constraint term was introduced for computing the BBS measurement. The performance of the proposed method is validated with Digital Retinal Images for Vessel Extraction (DRIVE and Standard Diabetic Retinopathy Database Calibration Level 1 (DIARETDB1 databases, and quantitative results were obtained. Success rates/error distances of 100%/10.4 pixel and of 97.7%/12.9 pixel, respectively, were achieved. The algorithm has been tested and compared with other commonly used methods, and the results show that the proposed method shows superior performance.

  18. Hand-held optical fuel pin scanner

    International Nuclear Information System (INIS)

    Kirchner, T.L.; Powers, H.G.

    1987-01-01

    A portable, hand-held apparatus is described for optically scanning indicia imprinted about a planar end face of an article having an outer wall surface, the apparatus comprising: a supporting frame; light detector means fixed to the frame for digitizing light patterns directed thereto; indexing means on the frame for engaging the planar end face and locating the end face in a preselected focal plane on the frame. The indexing means has an inner wall surface complementary to the article wall surface for disposition thereabout and terminates in an end portion beyond the planar end face. The inner wall surface has a radially inwardly extending shoulder spaced from the end portion and engageable with the planar end face; light means directed onto the preselected focal plane; optical means mounted on the frame about a central axis, the optical means being optically interposed between the indexing means and the light detector means for directing reflected light from the preselected focal plane to the light detector means and including a dove prism centrally aligned along the central axis; and means for selectively rotating the dove prism relative to the frame about the central axis to thereby rotate the image from the focal plane as transmitted to the light detector means

  19. 75 FR 27504 - Substantial Product Hazard List: Hand-Held Hair Dryers

    Science.gov (United States)

    2010-05-17

    ... immersion during their use. Section 15(a) of the CPSA defines ``substantial product hazard'' to include, a....'' Hand-held hair dryers routinely contain open-coil heating elements that are, in essence, uninsulated..., bathtub, or lavatory). The proposed rule would define ``hand-held hair dryer'' as ``an electrical...

  20. Attentionally splitting the mass distribution of hand-held rods.

    Science.gov (United States)

    Burton, G; Turvey, M T

    1991-08-01

    Two experiments on the length-perception capabilities of effortful or dynamic touch differed only in terms of what the subject intended to perceive, while experimental conditions and apparatus were held constant. In each trial, a visually occluded rod was held as still as possible by the subject at an intermediate position. For two thirds of the trials, a weight was attached to the rod above or below the hand. In Experiment 1, in which the subject's task was to perceive the distance reachable with the portion of the rod forward of the hand, perceived extent was a function of the first moment of the mass distribution associated with the forward portion of the rod, and indifferent to the first moment of the entire rod. In Experiment 2, in which the task was to perceive the distance reachable with the entire rod if it was held at an end, the pattern of results was reversed. These results indicate the capability of selective sensitivity to different aspects of a hand-held object's mass distribution, without the possibility of differential exploration specific to these two tasks. Results are discussed in relation to possible roles of differential information, intention, and self-organization in the explanations of selective perceptual abilities.

  1. Ultrasonography with a hand-held device for the diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Kameda, Toru; Takahashi, Isao

    2009-01-01

    The purpose of this study was to evaluate the accuracy of ultrasonography (US) with a hand-held device for the diagnosis of acute appendicitis in the emergency room. US with a hand-held device was performed by the first author in 33 patients suspected of having appendicitis in the emergency room. From these 33 patients, 24 who subsequently underwent computed tomography (CT) or surgery were included in this study. The accuracy of US with the hand-held device for the diagnosis of acute appendicitis was evaluated based on the findings of CT or surgery. CT and surgery were performed in 22 and 12 patients, respectively. Final diagnoses were acute appendicitis (n=18), terminal ileitis (n=2), pelvic inflammatory disease (n=2), diverticulitis (n=1), and ureterolithiasis (n=1). The US yielded a sensitivity of 78% and a positive predictive value of 100%. The shortest distance between the abdominal wall and the appendix measured on CT was less than 40 mm in 11 patients. In ten (91%) of the 11 patients US with the hand-held device showed the swollen appendix. US with a hand-held device is potentially useful in the positive identification of acute appendicitis, but further investigation is needed to prove its utility in the routine diagnosis of acute appendicitis. (author)

  2. Image analysis of ocular fundus for retinopathy characterization

    Energy Technology Data Exchange (ETDEWEB)

    Ushizima, Daniela; Cuadros, Jorge

    2010-02-05

    Automated analysis of ocular fundus images is a common procedure in countries as England, including both nonemergency examination and retinal screening of patients with diabetes mellitus. This involves digital image capture and transmission of the images to a digital reading center for evaluation and treatment referral. In collaboration with the Optometry Department, University of California, Berkeley, we have tested computer vision algorithms to segment vessels and lesions in ground-truth data (DRIVE database) and hundreds of images of non-macular centric and nonuniform illumination views of the eye fundus from EyePACS program. Methods under investigation involve mathematical morphology (Figure 1) for image enhancement and pattern matching. Recently, we have focused in more efficient techniques to model the ocular fundus vasculature (Figure 2), using deformable contours. Preliminary results show accurate segmentation of vessels and high level of true-positive microaneurysms.

  3. Adaptive RF front-ends for hand-held applications

    CERN Document Server

    van Bezooijen, Andre; van Roermund, Arthur

    2010-01-01

    The RF front-end - antenna combination is a vital part of a mobile phone because its performance is very relevant to the link quality between hand-set and cellular network base-stations. The RF front-end performance suffers from changes in operating environment, like hand-effects, that are often unpredictable. ""Adaptive RF Front-Ends for Hand-Held Applications"" presents an analysis on the impact of fluctuating environmental parameters. In order to overcome undesired behavior two different adaptive control methods are treated that make RF frond-ends more resilient: adaptive impedance control,

  4. Epilepsy Forewarning Using A Hand-Held Device

    Energy Technology Data Exchange (ETDEWEB)

    Hively, LM

    2005-02-21

    Over the last decade, ORNL has developed and patented a novel approach for forewarning of a large variety of machine and biomedical events. The present implementation uses desktop computers to analyze archival data. This report describes the next logical step in this effort, namely use of a hand-held device for the analysis.

  5. Leakage and scattered radiation from hand-held dental x-ray unit

    International Nuclear Information System (INIS)

    Kim, Eun Kyung

    2007-01-01

    To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR ΙΙΙ was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of hand-held dental X-ray unit were 70 kVp, 3 mA , 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. The mean dose at the hand level when human skull DXTTR ΙΙΙ was exposed with portable X-ray unit 6.39 μGy, and the mean dose with fixed X-ray unit 3.03 μGy (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was 2.97 μGy and with fixed X-ray unit the mean dose was 0.68 μGy (p<0.01). The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography

  6. Leakage and scattered radiation from hand-held dental x-ray unit

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Kyung [Dankook Univ. School of Dentistry, Seoul (Korea, Republic of)

    2007-06-15

    To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR {iota}{iota}{iota} was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of hand-held dental X-ray unit were 70 kVp, 3 mA , 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. The mean dose at the hand level when human skull DXTTR {iota}{iota}{iota} was exposed with portable X-ray unit 6.39 {mu}Gy, and the mean dose with fixed X-ray unit 3.03 {mu}Gy (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was 2.97 {mu}Gy and with fixed X-ray unit the mean dose was 0.68 {mu}Gy (p<0.01). The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography.

  7. Plans for Hand-Held/Portable Oil Assessment Devices

    National Research Council Canada - National Science Library

    Urbansky, Edward

    2005-01-01

    At the request of the U.S. Army Oil Analysis Program, the JOAP TSC conducted a market study, assembled a plan of action, and prepared a worksheet for the evaluation of portable or hand-held oil assessment devices...

  8. New portable hand-held radiation instruments for measurements and monitoring

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1987-01-01

    Hand-held radiation monitors are often used to search pedestrians and motor vehicles for special nuclear material (SNM) as part of a physical protection plan for nuclear materials. Recently, the Los Alamos Advanced Nuclear Technology group has commercialized an improved hand-held monitor that can be used for both physical-protection monitoring and verification measurements in nuclear material control and waste management. The new monitoring instruments are smaller and lighter; operate much longer on a battery charge; are available with NaI(Tl) or neutron and gamma-ray sensitive plastic scintillation detectors; and are less expensive than other comparable instruments. They also have a second operating mode for making precise measurements over counting times as long as 99 s. This mode permits making basic verification measurements that may be needed before transporting nuclear material or waste outside protected areas. Improved verification measurements can be made with a second new hand-held instrument that has a stabilized detector and three separate gamma-ray energy windows to obtain spectral information for SNM quantity, enrichment, or material-type verification

  9. Automated Detection and Differentiation of Drusen, Exudates, and Cotton-Wool Spots in Digital Color Fundus Photographs for Diabetic Retinopathy Diagnosis

    NARCIS (Netherlands)

    Niemeijer, M.; van Ginneken, B.; Russel, S.R.; Suttorp-Schulten, M.S.A.; Abràmoff, M.D.

    2007-01-01

    purpose. To describe and evaluate a machine learning-based, automated system to detect exudates and cotton-wool spots in digital color fundus photographs and differentiate them from drusen, for early diagnosis of diabetic retinopathy. methods. Three hundred retinal images from one eye of 300

  10. An Intelligent Hand-Held Microsurgical Instrument for Improved Accuracy

    National Research Council Canada - National Science Library

    Ang, Wei

    2001-01-01

    This paper presents the development and initial experimental results of the first prototype of Micron, an active hand-held instrument to sense and compensate physiological tremor and other unwanted...

  11. Position statement on use of hand-held portable dental X-ray equipment

    International Nuclear Information System (INIS)

    2014-06-01

    The position statement focuses on justification in the medical field, in particular on the use of hand-held portable dental x-ray equipment. It supplements another HERCA position paper, providing a general overview of the use of all hand-held portable X-ray equipment. Key Messages: - HERCA finds that the use of hand-held portable X-ray devices should be discouraged except in special circumstances. - As a general rule, these devices should only be used in scenarios where an intraoral radiograph is deemed necessary for a patient and the use of a fixed or semi-mobile x-ray unit is impractical, e.g.: - nursing homes, residential care facilities or homes for persons with disabilities; - forensic odontology, - military operations abroad without dental facilities

  12. Hand-held electronic data collection and procedure environment

    International Nuclear Information System (INIS)

    Kennedy, E.; Doniz, K.

    1996-01-01

    As part of a CANDU Owners Group project, AECL has developed a hand-held electronic data collection and procedure environment. Integral to this environment is the C omputerized Procedure Engine . The development of the CPE allows operators, maintainers, and technical support staff to execute virtually any type of station procedure on a general-purpose PC-compatible hand-held computer. There are several advantages to using the computerized procedures: less paper use and handling, reduction in human error, reduction in rework in the field, an increase in procedural compliance, and immediate availability of data to download to databases and plant information systems. The paper describes: the advantages of using computerized procedures, why early forms of computerized procedures were inadequate, the features that the C omputerized Procedure Engine o ffers to the user, the streamlined life cycle of a computerized procedure, and field experience. The paper concludes that computerized procedures are ready for pilot applications at stations. (author)

  13. Measuring thyroid uptake with hand-held radiation monitors

    International Nuclear Information System (INIS)

    Deschamps, M.

    1987-04-01

    With the use of Iodine 123, 125 and 131 and some compounds of Technetium-99 m, a fraction of the isotopes can be trapped in the thyroid of the technicians. We used the hand-held radiation contamination or survey meters of the nine (9) Nuclear medicine departments we visited to see if they were adequate for the evaluation of thyroid uptake of the users. Measurements on a neck-phanton helped us to determine a minimum detectable activity for each isotope. We were then able to check if the measurements of investigations and action levels were possible. None of the hand-held radiation monitors are completely satisfactory for the measure of thyroid uptake of the user. We discuss a class of equipment capable of measuring radiation emissions at the investigation level. Measurement at the action level is possible with meters having scintillation or proportional probes but none of them permits the discrimination in energy required for a quantitative evaluation of the radioisotopes used

  14. A natural approach to convey numerical digits using hand activity recognition based on hand shape features

    Science.gov (United States)

    Chidananda, H.; Reddy, T. Hanumantha

    2017-06-01

    This paper presents a natural representation of numerical digit(s) using hand activity analysis based on number of fingers out stretched for each numerical digit in sequence extracted from a video. The analysis is based on determining a set of six features from a hand image. The most important features used from each frame in a video are the first fingertip from top, palm-line, palm-center, valley points between the fingers exists above the palm-line. Using this work user can convey any number of numerical digits using right or left or both the hands naturally in a video. Each numerical digit ranges from 0 to9. Hands (right/left/both) used to convey digits can be recognized accurately using the valley points and with this recognition whether the user is a right / left handed person in practice can be analyzed. In this work, first the hand(s) and face parts are detected by using YCbCr color space and face part is removed by using ellipse based method. Then, the hand(s) are analyzed to recognize the activity that represents a series of numerical digits in a video. This work uses pixel continuity algorithm using 2D coordinate geometry system and does not use regular use of calculus, contours, convex hull and datasets.

  15. The availability of relatively cheap hand-held Global Positioning ...

    African Journals Online (AJOL)

    spamer

    conditions, so the approach failed to produce results ... Hand-held Global Positioning System (GPS) receivers provide opportunities for detailed and rapid mapping of features ..... TICKELL, W. L. N. 1968 — The biology of the great albatrosses,.

  16. Hand-held and automated breast ultrasound

    International Nuclear Information System (INIS)

    Bassett, L.W.; Gold, R.H.; Kimme-Smith, C.

    1985-01-01

    The book is a guide for physicians and technologists who use US as an adjunct to mammography; it carefully outlines the pros and cons of US of the breast and its role in the diagnosis of benign and malignant diseases. After an introduction that discusses the philosophy of breast US, the chapters cover the physics of US and instrumentation (both hand-held transducers as well as automated water path scanners), then proceed to a discussion of the normal breast. Sections on benign disorders, malignant lesions, and pitfalls of diagnosis are followed by quiz cases

  17. Quantitative evaluation of papilledema from stereoscopic color fundus photographs.

    Science.gov (United States)

    Tang, Li; Kardon, Randy H; Wang, Jui-Kai; Garvin, Mona K; Lee, Kyungmoo; Abràmoff, Michael D

    2012-07-03

    To derive a computerized measurement of optic disc volume from digital stereoscopic fundus photographs for the purpose of diagnosing and managing papilledema. Twenty-nine pairs of stereoscopic fundus photographs and optic nerve head (ONH) centered spectral domain optical coherence tomography (SD-OCT) scans were obtained at the same visit in 15 patients with papilledema. Some patients were imaged at multiple visits in order to assess their changes. Three-dimensional shape of the ONH was estimated from stereo fundus photographs using an automated multi-scale stereo correspondence algorithm. We assessed the correlation of the stereo volume measurements with the SD-OCT volume measurements quantitatively, in terms of volume of retinal surface elevation above a reference plane and also to expert grading of papilledema from digital fundus photographs using the Frisén grading scale. The volumetric measurements of retinal surface elevation estimated from stereo fundus photographs and OCT scans were positively correlated (correlation coefficient r(2) = 0.60; P photographs compares favorably with that from OCT scans and with expert grading of papilledema severity. Stereoscopic color imaging of the ONH combined with a method of automated shape reconstruction is a low-cost alternative to SD-OCT scans that has potential for a more cost-effective diagnosis and management of papilledema in a telemedical setting. An automated three-dimensional image analysis method was validated that quantifies the retinal surface topography with an imaging modality that has lacked prior objective assessment.

  18. Hand held data collection and monitoring system for nuclear facilities

    Science.gov (United States)

    Brayton, D.D.; Scharold, P.G.; Thornton, M.W.; Marquez, D.L.

    1999-01-26

    Apparatus and method is disclosed for a data collection and monitoring system that utilizes a pen based hand held computer unit which has contained therein interaction software that allows the user to review maintenance procedures, collect data, compare data with historical trends and safety limits, and input new information at various collection sites. The system has a means to allow automatic transfer of the collected data to a main computer data base for further review, reporting, and distribution purposes and uploading updated collection and maintenance procedures. The hand held computer has a running to-do list so sample collection and other general tasks, such as housekeeping are automatically scheduled for timely completion. A done list helps users to keep track of all completed tasks. The built-in check list assures that work process will meet the applicable processes and procedures. Users can hand write comments or drawings with an electronic pen that allows the users to directly interface information on the screen. 15 figs.

  19. Hand held data collection and monitoring system for nuclear facilities

    International Nuclear Information System (INIS)

    Brayton, D.D.; Scharold, P.G.; Thornton, M.W.; Marquez, D.L.

    1999-01-01

    Apparatus and method is disclosed for a data collection and monitoring system that utilizes a pen based hand held computer unit which has contained therein interaction software that allows the user to review maintenance procedures, collect data, compare data with historical trends and safety limits, and input new information at various collection sites. The system has a means to allow automatic transfer of the collected data to a main computer data base for further review, reporting, and distribution purposes and uploading updated collection and maintenance procedures. The hand held computer has a running to-do list so sample collection and other general tasks, such as housekeeping are automatically scheduled for timely completion. A done list helps users to keep track of all completed tasks. The built-in check list assures that work process will meet the applicable processes and procedures. Users can hand write comments or drawings with an electronic pen that allows the users to directly interface information on the screen. 15 figs

  20. Interactive topology optimization on hand-held devices

    DEFF Research Database (Denmark)

    Aage, Niels; Nobel-Jørgensen, Morten; Andreasen, Casper Schousboe

    2013-01-01

    This paper presents an interactive topology optimization application designed for hand-held devices running iOS or Android. The TopOpt app solves the 2D minimum compliance problem with interactive control of load and support positions as well as volume fraction. Thus, it is possible to change......OS devices from the Apple App Store, at Google Play for the Android platform, and a web-version can be run from www.topopt.dtu.dk....

  1. A hand-held robotic device for peripheral intravenous catheterization.

    Science.gov (United States)

    Cheng, Zhuoqi; Davies, Brian L; Caldwell, Darwin G; Barresi, Giacinto; Xu, Qinqi; Mattos, Leonardo S

    2017-12-01

    Intravenous catheterization is frequently required for numerous medical treatments. However, this process is characterized by a high failure rate, especially when performed on difficult patients such as newborns and infants. Very young patients have small veins, and that increases the chances of accidentally puncturing the catheterization needle directly through them. In this article, we present the design, development and experimental evaluation of a novel hand-held robotic device for improving the process of peripheral intravenous catheterization by facilitating the needle insertion procedure. To our knowledge, this design is the first hand-held robotic device for assisting in the catheterization insertion task. Compared to the other available technologies, it has several unique advantages such as being compact, low-cost and able to reliably detect venipuncture. The system is equipped with an electrical impedance sensor at the tip of the catheterization needle, which provides real-time measurements used to supervise and control the catheter insertion process. This allows the robotic system to precisely position the needle within the lumen of the target vein, leading to enhanced catheterization success rate. Experiments conducted to evaluate the device demonstrated that it is also effective to deskill the task. Naïve subjects achieved an average catheterization success rate of 88% on a 1.5 mm phantom vessel with the robotic device versus 12% with the traditional unassisted system. The results of this work prove the feasibility of a hand-held assistive robotic device for intravenous catheterization and show that such device has the potential to greatly improve the success rate of these difficult operations.

  2. Diagnosing and ranking retinopathy disease level using diabetic fundus image recuperation approach.

    Science.gov (United States)

    Somasundaram, K; Rajendran, P Alli

    2015-01-01

    Retinal fundus images are widely used in diagnosing different types of eye diseases. The existing methods such as Feature Based Macular Edema Detection (FMED) and Optimally Adjusted Morphological Operator (OAMO) effectively detected the presence of exudation in fundus images and identified the true positive ratio of exudates detection, respectively. These mechanically detected exudates did not include more detailed feature selection technique to the system for detection of diabetic retinopathy. To categorize the exudates, Diabetic Fundus Image Recuperation (DFIR) method based on sliding window approach is developed in this work to select the features of optic cup in digital retinal fundus images. The DFIR feature selection uses collection of sliding windows with varying range to obtain the features based on the histogram value using Group Sparsity Nonoverlapping Function. Using support vector model in the second phase, the DFIR method based on Spiral Basis Function effectively ranks the diabetic retinopathy disease level. The ranking of disease level on each candidate set provides a much promising result for developing practically automated and assisted diabetic retinopathy diagnosis system. Experimental work on digital fundus images using the DFIR method performs research on the factors such as sensitivity, ranking efficiency, and feature selection time.

  3. Validity of maximal isometric knee extension strength measurements obtained via belt-stabilized hand-held dynamometry in healthy adults.

    Science.gov (United States)

    Ushiyama, Naoko; Kurobe, Yasushi; Momose, Kimito

    2017-11-01

    [Purpose] To determine the validity of knee extension muscle strength measurements using belt-stabilized hand-held dynamometry with and without body stabilization compared with the gold standard isokinetic dynamometry in healthy adults. [Subjects and Methods] Twenty-nine healthy adults (mean age, 21.3 years) were included. Study parameters involved right side measurements of maximal isometric knee extension strength obtained using belt-stabilized hand-held dynamometry with and without body stabilization and the gold standard. Measurements were performed in all subjects. [Results] A moderate correlation and fixed bias were found between measurements obtained using belt-stabilized hand-held dynamometry with body stabilization and the gold standard. No significant correlation and proportional bias were found between measurements obtained using belt-stabilized hand-held dynamometry without body stabilization and the gold standard. The strength identified using belt-stabilized hand-held dynamometry with body stabilization may not be commensurate with the maximum strength individuals can generate; however, it reflects such strength. In contrast, the strength identified using belt-stabilized hand-held dynamometry without body stabilization does not reflect the maximum strength. Therefore, a chair should be used to stabilize the body when performing measurements of maximal isometric knee extension strength using belt-stabilized hand-held dynamometry in healthy adults. [Conclusion] Belt-stabilized hand-held dynamometry with body stabilization is more convenient than the gold standard in clinical settings.

  4. Interoperative fundus image and report sharing in compliance with integrating the healthcare enterprise conformance and web access to digital imaging and communication in medicine persistent object protocol.

    Science.gov (United States)

    Wu, Hui-Qun; Lv, Zheng-Min; Geng, Xing-Yun; Jiang, Kui; Tang, Le-Min; Zhou, Guo-Min; Dong, Jian-Cheng

    2013-01-01

    To address issues in interoperability between different fundus image systems, we proposed a web eye-picture archiving and communication system (PACS) framework in conformance with digital imaging and communication in medicine (DICOM) and health level 7 (HL7) protocol to realize fundus images and reports sharing and communication through internet. Firstly, a telemedicine-based eye care work flow was established based on integrating the healthcare enterprise (IHE) Eye Care technical framework. Then, a browser/server architecture eye-PACS system was established in conformance with the web access to DICOM persistent object (WADO) protocol, which contains three tiers. In any client system installed with web browser, clinicians could log in the eye-PACS to observe fundus images and reports. Multipurpose internet mail extensions (MIME) type of a structured report is saved as pdf/html with reference link to relevant fundus image using the WADO syntax could provide enough information for clinicians. Some functions provided by open-source Oviyam could be used to query, zoom, move, measure, view DICOM fundus images. Such web eye-PACS in compliance to WADO protocol could be used to store and communicate fundus images and reports, therefore is of great significance for teleophthalmology.

  5. Diagnosing and Ranking Retinopathy Disease Level Using Diabetic Fundus Image Recuperation Approach

    Directory of Open Access Journals (Sweden)

    K. Somasundaram

    2015-01-01

    Full Text Available Retinal fundus images are widely used in diagnosing different types of eye diseases. The existing methods such as Feature Based Macular Edema Detection (FMED and Optimally Adjusted Morphological Operator (OAMO effectively detected the presence of exudation in fundus images and identified the true positive ratio of exudates detection, respectively. These mechanically detected exudates did not include more detailed feature selection technique to the system for detection of diabetic retinopathy. To categorize the exudates, Diabetic Fundus Image Recuperation (DFIR method based on sliding window approach is developed in this work to select the features of optic cup in digital retinal fundus images. The DFIR feature selection uses collection of sliding windows with varying range to obtain the features based on the histogram value using Group Sparsity Nonoverlapping Function. Using support vector model in the second phase, the DFIR method based on Spiral Basis Function effectively ranks the diabetic retinopathy disease level. The ranking of disease level on each candidate set provides a much promising result for developing practically automated and assisted diabetic retinopathy diagnosis system. Experimental work on digital fundus images using the DFIR method performs research on the factors such as sensitivity, ranking efficiency, and feature selection time.

  6. Strategies of digital fundus photography for screening diabetic retinopathy in a diabetic population in urban China.

    Science.gov (United States)

    Ding, Jiyuan; Zou, Yanhong; Liu, Ningpu; Jiang, Li; Ren, Xuetao; Jia, Wei; Snellingen, Torkel; Chongsuvivatwong, Virasakdi; Liu, Xipu

    2012-12-01

    To evaluate the effect of mydriasis and different field strategies on technical failure, probability to refer diabetic retinopathy (DR, sensitivity) and probability not to refer patients without DR (specificity) of digital photography in screening with a fundus camera. A total of 531 patients with diabetes underwent fundus photography with cross-combinations of mydriasis/nonmydriasis and single-field/two-field strategies, followed by slit lamp biomicroscopic examination by a trained ophthalmologist. Fundus photographs were graded independently by another experienced ophthalmologist. Calculations were first based on cases with non-gradable images treated as being referred and then with them excluded. Percentages of DR and referable DR in this patient cohort were 22.4% and 7.7%, respectively, based on slit lamp biomicroscopic examination. Mydriasis significantly reduced the technical failure rate from 27.1% to 8.3% under a single-field strategy, and from 28.2% to 8.9% under a two-field strategy. As compared to the single-field strategy, the two-field strategy increased sensitivity from 75.6% to 87.8% without mydriasis and from 73.2% to 90.2% with mydriasis. Mydriasis increased specificity from 68.8% to 84.3% in the single-field strategy and from 64.7% to 81.6% in the two-field strategy. Had the subjects with non-gradable images been excluded, the two-field strategy without mydriasis reported sensitivity of 85.7% and specificity of 91.6%. Both mydriasis and the two-field strategy are useful in photographic screening tests. Technical failure should be taken into consideration when screening strategies for DR are determined.

  7. Hand-held cell phone use while driving legislation and observed driver behavior among population sub-groups in the United States.

    Science.gov (United States)

    Rudisill, Toni M; Zhu, Motao

    2017-05-12

    Cell phone use behaviors are known to vary across demographic sub-groups and geographic locations. This study examined whether universal hand-held calling while driving bans were associated with lower road-side observed hand-held cell phone conversations across drivers of different ages (16-24, 25-59, ≥60 years), sexes, races (White, African American, or other), ruralities (suburban, rural, or urban), and regions (Northeast, Midwest, South, and West). Data from the 2008-2013 National Occupant Protection Use Survey were merged with states' cell phone use while driving legislation. The exposure was presence of a universal hand-held cell phone ban at time of observation. Logistic regression was used to assess the odds of drivers having a hand-held cell phone conversation. Sub-groups differences were assessed using models with interaction terms. When universal hand-held cell phone bans were effective, hand-held cell phone conversations were lower across all driver demographic sub-groups and regions. Sub-group differences existed among the sexes (p-value, phone bans, the adjusted odds ratio (aOR) of a driver hand-held phone conversation was 0.34 [95% confidence interval (CI): 0.28, 0.41] for females versus 0.47 (CI 0.40, 0.55) for males and 0.31 (CI 0.25, 0.38) for drivers in Western states compared to 0.47 (CI 0.30, 0.72) in the Northeast and 0.50 (CI 0.38, 0.66) in the South. The presence of universal hand-held cell phone bans were associated lower hand-held cell phone conversations across all driver sub-groups and regions. Hand-held phone conversations were particularly lower among female drivers and those from Western states when these bans were in effect. Public health interventions concerning hand-held cell phone use while driving could reasonably target all drivers.

  8. Hand-held cell phone use while driving legislation and observed driver behavior among population sub-groups in the United States

    Directory of Open Access Journals (Sweden)

    Toni M. Rudisill

    2017-05-01

    Full Text Available Abstract Background Cell phone use behaviors are known to vary across demographic sub-groups and geographic locations. This study examined whether universal hand-held calling while driving bans were associated with lower road-side observed hand-held cell phone conversations across drivers of different ages (16–24, 25–59, ≥60 years, sexes, races (White, African American, or other, ruralities (suburban, rural, or urban, and regions (Northeast, Midwest, South, and West. Methods Data from the 2008–2013 National Occupant Protection Use Survey were merged with states’ cell phone use while driving legislation. The exposure was presence of a universal hand-held cell phone ban at time of observation. Logistic regression was used to assess the odds of drivers having a hand-held cell phone conversation. Sub-groups differences were assessed using models with interaction terms. Results When universal hand-held cell phone bans were effective, hand-held cell phone conversations were lower across all driver demographic sub-groups and regions. Sub-group differences existed among the sexes (p-value, <0.0001 and regions (p-value, 0.0003. Compared to states without universal hand-held cell phone bans, the adjusted odds ratio (aOR of a driver hand-held phone conversation was 0.34 [95% confidence interval (CI: 0.28, 0.41] for females versus 0.47 (CI 0.40, 0.55 for males and 0.31 (CI 0.25, 0.38 for drivers in Western states compared to 0.47 (CI 0.30, 0.72 in the Northeast and 0.50 (CI 0.38, 0.66 in the South. Conclusions The presence of universal hand-held cell phone bans were associated lower hand-held cell phone conversations across all driver sub-groups and regions. Hand-held phone conversations were particularly lower among female drivers and those from Western states when these bans were in effect. Public health interventions concerning hand-held cell phone use while driving could reasonably target all drivers.

  9. Combining heterogenous features for 3D hand-held object recognition

    Science.gov (United States)

    Lv, Xiong; Wang, Shuang; Li, Xiangyang; Jiang, Shuqiang

    2014-10-01

    Object recognition has wide applications in the area of human-machine interaction and multimedia retrieval. However, due to the problem of visual polysemous and concept polymorphism, it is still a great challenge to obtain reliable recognition result for the 2D images. Recently, with the emergence and easy availability of RGB-D equipment such as Kinect, this challenge could be relieved because the depth channel could bring more information. A very special and important case of object recognition is hand-held object recognition, as hand is a straight and natural way for both human-human interaction and human-machine interaction. In this paper, we study the problem of 3D object recognition by combining heterogenous features with different modalities and extraction techniques. For hand-craft feature, although it reserves the low-level information such as shape and color, it has shown weakness in representing hiconvolutionalgh-level semantic information compared with the automatic learned feature, especially deep feature. Deep feature has shown its great advantages in large scale dataset recognition but is not always robust to rotation or scale variance compared with hand-craft feature. In this paper, we propose a method to combine hand-craft point cloud features and deep learned features in RGB and depth channle. First, hand-held object segmentation is implemented by using depth cues and human skeleton information. Second, we combine the extracted hetegerogenous 3D features in different stages using linear concatenation and multiple kernel learning (MKL). Then a training model is used to recognize 3D handheld objects. Experimental results validate the effectiveness and gerneralization ability of the proposed method.

  10. Development of dual sensor hand-held detector

    Science.gov (United States)

    Sezgin, Mehmet

    2010-04-01

    In this paper hand-held dual sensor detector development requirements are considered dedicated to buried object detection. Design characteristics of such a system are categorized and listed. Hardware and software structures, ergonomics, user interface, environmental and EMC/EMI tests to be applied and performance test issues are studied. Main properties of the developed system (SEZER) are presented, which contains Metal Detector (MD) and Ground Penetrating Radar (GPR). The realized system has ergonomic structure and can detect both metallic and non-metallic buried objects. Moreover classification of target is possible if it was defined to the signal processing software in learning phase.

  11. Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children

    Directory of Open Access Journals (Sweden)

    Janson C

    2006-04-01

    Full Text Available Abstract Background Exhaled nitric oxide (NO measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO was compared with a standard stationary chemiluminescence unit (NIOX. Methods A total of 71 subjects (6–60 years; 36 males, both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots, measurement feasibility (success rate with 6 attempts and repeatability (intrasubject SD. Results Success rate was high (≥ 84% in both devices for both adults and children. The subjects represented a FENO range of 8–147 parts per billion (ppb. When comparing the mean of three measurements (n = 61, the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. Conclusion The hand-held device (NIOX MINO and the stationary system (NIOX are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO is used. The hand-held device shows good repeatability, and it

  12. Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children.

    Science.gov (United States)

    Alving, K; Janson, C; Nordvall, L

    2006-04-20

    Exhaled nitric oxide (NO) measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO) was compared with a standard stationary chemiluminescence unit (NIOX). A total of 71 subjects (6-60 years; 36 males), both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s) in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots), measurement feasibility (success rate with 6 attempts) and repeatability (intrasubject SD). Success rate was high (> or = 84%) in both devices for both adults and children. The subjects represented a FENO range of 8-147 parts per billion (ppb). When comparing the mean of three measurements (n = 61), the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. The hand-held device (NIOX MINO) and the stationary system (NIOX) are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO) is used. The hand-held device shows good repeatability, and it can be used successfully on adults and most children

  13. How to use hand-held computers to evaluate wood drying.

    Science.gov (United States)

    Howard N. Rosen; Darrell S. Martin

    1985-01-01

    Techniques have been developed to evaluate end generate wood drying curves with hand-held computers (3-5K memory). Predictions of time to dry to a specific moisture content, drying rates, and other characteristics of wood drying curves can be made. The paper describes the development of programs and illustrates their use.

  14. The diagnostic accuracy of single- and five-field fundus photography in diabetic retinopathy screening by primary care physicians.

    Science.gov (United States)

    Srihatrai, Parinya; Hlowchitsieng, Thanita

    2018-01-01

    The aim is to evaluate the diagnostic accuracy of digital fundus photography in diabetic retinopathy (DR) screening at a single university hospital. This was a cross-sectional hospital-based study. One hundred and ninety-eight diabetic patients were recruited for comprehensive eye examination by two ophthalmologists. Five-field fundus photographs were taken with a digital, nonmydriatic fundus camera, and trained primary care physicians then graded the severity of DR present by single-field 45° and five-field fundus photography. Sensitivity and specificity of DR grading were reported using the findings from the ophthalmologists' examinations as a gold standard. When fundus photographs of the participants' 363 eyes were analyzed for the presence of DR, there was substantial agreement between the two primary care physicians, κ = 0.6226 for single-field and 0.6939 for five-field photograph interpretation. The sensitivity and specificity of DR detection with single-field photographs were 70.7% (95% Confidence interval [CI]; 60.2%-79.7%) and 99.3% (95% CI; 97.4%-99.9%), respectively. Sensitivity and specificity for five-field photographs were 84.5% (95% CI; 75.8%-91.1%) and 98.6% (95% CI; 96.5%-99.6%), respectively. The receiver operating characteristic was 0.85 (0.80-0.90) for single-field photographs and 0.92 (0.88-0.95) for five-field photographs. The sensitivity and specificity of fundus photographs for DR detection by primary care physicians were acceptable. Single- and five-field digital fundus photography each represent a convenient screening tool with acceptable accuracy.

  15. 78 FR 27441 - NIJ Evaluation of Hand-Held Cell Phone Detector Devices

    Science.gov (United States)

    2013-05-10

    ...The National Institute of Justice (NIJ) is soliciting interest in supplying hand-held cell phone detector devices for participation in an evaluation by the NIJ Corrections Technology Center of Excellence (CXCoE).

  16. 78 FR 73415 - Safety Standard for Hand-Held Infant Carriers

    Science.gov (United States)

    2013-12-06

    ... modifications to the ASTM test procedure set forth in ASTM F2050-12 so that the test produces more repeatable... skills necessary for the preparation of reports or records; and a description of the steps the agency has... the Rule on Small Business There are at least 47 firms currently known to be marketing hand- held...

  17. The Weak Link HP-41C hand-held calculator program

    Science.gov (United States)

    Ross A. Phillips; Penn A. Peters; Gary D. Falk

    1982-01-01

    The Weak Link hand-held calculator program (HP-41C) quickly analyzes a system for logging production and costs. The production equations model conventional chain saw, skidder, loader, and tandemaxle truck operations in eastern mountain areas. Production of each function of the logging system may be determined so that the system may be balanced for minimum cost. The...

  18. Hand-held transendoscopic robotic manipulators: A transurethral laser prostate surgery case study.

    Science.gov (United States)

    Hendrick, Richard J; Mitchell, Christopher R; Herrell, S Duke; Webster, Robert J

    2015-11-01

    Natural orifice endoscopic surgery can enable incisionless approaches, but a major challenge is the lack of small and dexterous instrumentation. Surgical robots have the potential to meet this need yet often disrupt the clinical workflow. Hand-held robots that combine thin manipulators and endoscopes have the potential to address this by integrating seamlessly into the clinical workflow and enhancing dexterity. As a case study illustrating the potential of this approach, we describe a hand-held robotic system that passes two concentric tube manipulators through a 5 mm port in a rigid endoscope for transurethral laser prostate surgery. This system is intended to catalyze the use of a clinically superior, yet rarely attempted, procedure for benign prostatic hyperplasia. This paper describes system design and experiments to evaluate the surgeon's functional workspace and accuracy using the robot. Phantom and cadaver experiments demonstrate successful completion of the target procedure via prostate lobe resection.

  19. Hand held lasers, a hazard to aircraft: How do we address this?

    Science.gov (United States)

    Barat, K.

    2015-10-01

    The availability of hand held lasers, commonly termed "laser pointers" is easy and wide spread, through commercial web sites and brick & mortar stores. The output of these hand held devices ranges from 1-5 milliWatts (mW) the legal laser pointer output limit, to 5000mW (5Watts). This is thousand times the maximum limit for pointers. Sadly the abuse of these devices is also wide spread. Over the last few years over 3000 aircraft are exposed to laser hits per year. While these aircraft exposures are of no danger to the aircraft frame but they can cause pilot distractions with the potential to cause a serve accident. The presentation will discuss the problem review visual effects, the regulatory response and how educators need to be aware of the problem and can take steps to educate students in the hope of having an effect.

  20. Hand-held spectrophotometer design for textile fabrics

    Science.gov (United States)

    Böcekçi, Veysel Gökhan; Yıldız, Kazım

    2017-09-01

    In this study, a hand-held spectrophotometer was designed by taking advantage of the developments in modern optoelectronic technology. Spectrophotometer devices are used to determine the color information from the optic properties of the materials. As an alternative to a desktop spectrophotometer device we have implemented, it is the first prototype, low cost and portable. The prototype model designed for the textile industry can detect the color tone of any fabric. The prototype model consists of optic sensor, processor, display floors. According to the color applied on the optic sensor, it produces special frequency information on its output at that color value. In Arduino type processor, the frequency information is evaluated by the program we have written and the color tone information between 0-255 ton is decided and displayed on the screen.

  1. Gen-2 Hand-Held Optical Imager towards Cancer Imaging: Reflectance and Transillumination Phantom Studies

    Directory of Open Access Journals (Sweden)

    Anuradha Godavarty

    2012-02-01

    Full Text Available Hand-held near-infrared (NIR optical imagers are developed by various researchers towards non-invasive clinical breast imaging. Unlike these existing imagers that can perform only reflectance imaging, a generation-2 (Gen-2 hand-held optical imager has been recently developed to perform both reflectance and transillumination imaging. The unique forked design of the hand-held probe head(s allows for reflectance imaging (as in ultrasound and transillumination or compressed imaging (as in X-ray mammography. Phantom studies were performed to demonstrate two-dimensional (2D target detection via reflectance and transillumination imaging at various target depths (1–5 cm deep and using simultaneous multiple point illumination approach. It was observed that 0.45 cc targets were detected up to 5 cm deep during transillumination, but limited to 2.5 cm deep during reflectance imaging. Additionally, implementing appropriate data post-processing techniques along with a polynomial fitting approach, to plot 2D surface contours of the detected signal, yields distinct target detectability and localization. The ability of the gen-2 imager to perform both reflectance and transillumination imaging allows its direct comparison to ultrasound and X-ray mammography results, respectively, in future clinical breast imaging studies.

  2. The reliability and validity of hand-held refractometry water content measures of hydrogel lenses.

    Science.gov (United States)

    Nichols, Jason J; Mitchell, G Lynn; Good, Gregory W

    2003-06-01

    To investigate within- and between-examiner reliability and validity of hand-held refractometry water content measures of hydrogel lenses. Nineteen lenses of various nominal water contents were examined by two examiners on two occasions separated by 1 hour. An Atago N2 hand-held refractometer was used for all water content measures. Lenses were presented in a random order to each examiner by a third party, and examiners were masked to any potential lens identifiers. Intraclass correlation coefficients (ICC), 95% limits of agreement, and Wilcoxon signed rank test were used to characterize the within- and between-examiner reliability and validity of lens water content measures. Within-examiner reliability was excellent (ICC, 0.97; 95% limits of agreement, -3.6% to +5.7%), and the inter-visit mean difference of 1.1 +/- 2.4% was not biased (p = 0.08). Between-examiner reliability was also excellent (ICC, 0.98; 95% limits of agreement, -4.1% to +3.9%). The mean difference between examiners was -0.1 +/- 2.1% (p = 0.83). The mean difference between the nominally reported water content and our water content measures was -2.1 +/- 1.7% (p refractometry and is material dependent. Therefore, investigators may need to account for bias when measuring hydrogel lens water content via hand-held refractometry.

  3. Balancing fast-rotating parts of hand-held machine drive

    Science.gov (United States)

    Korotkov, V. S.; Sicora, E. A.; Nadeina, L. V.; Yongzheng, Wang

    2018-03-01

    The article considers the issues related to the balancing of fast rotating parts of the hand-held machine drive including a wave transmission with intermediate rolling elements, which is constructed on the basis of the single-phase collector motor with a useful power of 1 kW and a nominal rotation frequency of 15000 rpm. The forms of balancers and their location are chosen. The method of balancing is described. The scheme for determining of residual unbalance in two correction planes is presented. Measurement results are given in tables.

  4. Radiation safety evaluation of a hand-held, battery operated image intensifier

    International Nuclear Information System (INIS)

    Wilson, O.J.; Young, B.F.

    1987-01-01

    A portable, hand-held, fluoroscopic unit intended for medical and industrial use was tested to verify the claim of the manufacturers that the radiation doses to the patient and user are low, and comparable to those received from standard radiographic procedures. The first claim was substantiated but not the second. A number of concerns arising from the use of this unit are discussed

  5. Comparative Geometrical Accuracy Investigations of Hand-Held 3d Scanning Systems - AN Update

    Science.gov (United States)

    Kersten, T. P.; Lindstaedt, M.; Starosta, D.

    2018-05-01

    Hand-held 3D scanning systems are increasingly available on the market from several system manufacturers. These systems are deployed for 3D recording of objects with different size in diverse applications, such as industrial reverse engineering, and documentation of museum exhibits etc. Typical measurement distances range from 0.5 m to 4.5 m. Although they are often easy-to-use, the geometric performance of these systems, especially the precision and accuracy, are not well known to many users. First geometrical investigations of a variety of diverse hand-held 3D scanning systems were already carried out by the Photogrammetry & Laser Scanning Lab of the HafenCity University Hamburg (HCU Hamburg) in cooperation with two other universities in 2016. To obtain more information about the accuracy behaviour of the latest generation of hand-held 3D scanning systems, HCU Hamburg conducted further comparative geometrical investigations using structured light systems with speckle pattern (Artec Spider, Mantis Vision PocketScan 3D, Mantis Vision F5-SR, Mantis Vision F5-B, and Mantis Vision F6), and photogrammetric systems (Creaform HandySCAN 700 and Shining FreeScan X7). In the framework of these comparative investigations geometrically stable reference bodies were used. The appropriate reference data was acquired by measurements with two structured light projection systems (AICON smartSCAN and GOM ATOS I 2M). The comprehensive test results of the different test scenarios are presented and critically discussed in this contribution.

  6. Comparison of digital color fundus imaging and fluorescein angiographic findings for the early detection of diabetic retinopathy in young type 1 diabetic patients.

    Science.gov (United States)

    Kapsala, Z; Anastasakis, A; Mamoulakis, D; Maniadaki, I; Tsilimbaris, M

    2018-01-01

    To compare the findings from digital 7-field color fundus (CF) photography and fundus fluorescein angiography (FFA) in young patients with diabetes mellitus (DM) type 1 without known diabetic retinopathy. In this prospective, observational cohort study, 54 type 1 diabetic patients were recruited. Participants had been diagnosed with diabetes mellitus (DM) for at least 6 years, had Best Corrected Visual Acuity of 20/25 or better and did not have any known retinal pathology. One hundred and seven eyes were analyzed. All patients underwent a complete ophthalmic examination in the Retina Service of a University Eye Clinic including digital CF imaging and FFA. The mean age of the patients was 18.6 years. Mean duration of DM was 11.3 years, and mean haemoglobin A1c (HbA1c) level was 8.6%. Of the 107 eyes, 8 eyes (7.5%) showed microvascular abnormalities on CF images, while FFA images revealed changes in 26 eyes (24.3%). Hence, 18 of the 26 eyes showing abnormalities on FFA did not show any abnormalities on CF images. Mean DM duration in the patient group with detectable microvascular changes was found to be significantly higher compared to patients without changes, while no difference in HbA1c levels, serum lipid levels or blood pressure was observed. Comparison of digital CF and FFA findings for the detection of diabetic microvascular changes in type 1 diabetic patients showed that FFA reveals more information about retinal vascular pathology for early detection of diabetic retinopathy. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  7. Fundus autofluorescence and the bisretinoids of retina.

    Science.gov (United States)

    Sparrow, Janet R; Wu, Yalin; Nagasaki, Takayuki; Yoon, Kee Dong; Yamamoto, Kazunori; Zhou, Jilin

    2010-11-01

    Imaging of the human fundus of the eye with excitation wavelengths in the visible spectrum reveals a natural autofluorescence, that in a healthy retina originates primarily from the bisretinoids that constitute the lipofuscin of retinal pigment epithelial (RPE) cells. Since the intensity and distribution of fundus autofluorescence is altered in the presence of retinal disease, we have examined the fluorescence properties of the retinal bisretinoids with a view to aiding clinical interpretations. As is also observed for fundus autofluorescence, fluorescence emission from RPE lipofuscin was generated with a wide range of exciting wavelengths; with increasing excitation wavelength, the emission maximum shifted towards longer wavelengths and spectral width was decreased. These features are consistent with fluorescence generation from a mixture of compounds. While the bisretinoids that constitute RPE lipofuscin all fluoresced with maxima that were centered around 600 nm, fluorescence intensities varied when excited at 488 nm, the excitation wavelength utilized for fundus autofuorescence imaging. For instance the fluorescence efficiency of the bisretinoid A2-dihydropyridine-phosphatidylethanolamine (A2-DHP-PE) was greater than A2E and relative to both of the latter, all-trans-retinal dimer-phosphatidylethanolamine was weakly fluorescent. On the other hand, certain photooxidized forms of the bisretinoids present in both RPE and photoreceptor cells were more strongly fluorescent than the parent compound. We also sought to evaluate whether diffuse puncta of autofluorescence observed in some retinal disorders of monogenic origin are attributable to retinoid accumulation. However, two retinoids of the visual cycle, all-trans-retinyl ester and all-trans-retinal, did not exhibit fluorescence at 488 nm excitation.

  8. Standard guide to In-Plant performance evaluation of Hand-Held SNM monitors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This guide is one of a series on the application and evaluation of special nuclear material (SNM) monitors. Other guides in the series are listed in Section 2, and the relationship of in-plant performance evaluation to other procedures described in the series is illustrated in Fig. 1. Hand-held SNM monitors are described in of Guide C1112, and performance criteria illustrating their capabilities can be found in Appendix X1. 1.2 The purpose of this guide to in-plant performance evaluation is to provide a comparatively rapid procedure to verify that a hand-held SNM monitor performs as expected for detecting SNM or alternative test sources or to disclose the need for repair. The procedure can be used as a routine operational evaluation or it can be used to verify performance after a monitor is calibrated. 1.3 In-plant performance evaluations are more comprehensive than daily functional tests. They take place less often, at intervals ranging from weekly to once every three months, and derive their result fr...

  9. Implementation of synthetic aperture imaging on a hand-held device

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian; Kjeldsen, Thomas; Larsen, Lee

    2014-01-01

    -held devices all with different chipsets and a BK Medical UltraView 800 ultrasound scanner emulating a wireless probe. The wireless transmission is benchmarked using an imaging setup consisting of 269 scan lines x 1472 complex samples (1.58 MB pr. frame, 16 frames per second). The measured data throughput...... reached an average of 28.8 MB/s using a LG G2 mobile device, which is more than the required data throughput of 25.3 MB/s. Benchmarking the processing performance for B-mode imaging showed a total processing time of 18.9 ms (53 frames/s), which is less than the acquisition time (62.5 ms).......This paper presents several implementations of Syn- thetic Aperture Sequential Beamforming (SASB) on commer- cially available hand-held devices. The implementations include real-time wireless reception of ultrasound radio frequency sig- nals and GPU processing for B-mode imaging. The proposed...

  10. Force-independent distribution of correlated neural inputs to hand muscles during three-digit grasping.

    Science.gov (United States)

    Poston, Brach; Danna-Dos Santos, Alessander; Jesunathadas, Mark; Hamm, Thomas M; Santello, Marco

    2010-08-01

    The ability to modulate digit forces during grasping relies on the coordination of multiple hand muscles. Because many muscles innervate each digit, the CNS can potentially choose from a large number of muscle coordination patterns to generate a given digit force. Studies of single-digit force production tasks have revealed that the electromyographic (EMG) activity scales uniformly across all muscles as a function of digit force. However, the extent to which this finding applies to the coordination of forces across multiple digits is unknown. We addressed this question by asking subjects (n = 8) to exert isometric forces using a three-digit grip (thumb, index, and middle fingers) that allowed for the quantification of hand muscle coordination within and across digits as a function of grasp force (5, 20, 40, 60, and 80% maximal voluntary force). We recorded EMG from 12 muscles (6 extrinsic and 6 intrinsic) of the three digits. Hand muscle coordination patterns were quantified in the amplitude and frequency domains (EMG-EMG coherence). EMG amplitude scaled uniformly across all hand muscles as a function of grasp force (muscle x force interaction: P = 0.997; cosines of angle between muscle activation pattern vector pairs: 0.897-0.997). Similarly, EMG-EMG coherence was not significantly affected by force (P = 0.324). However, coherence was stronger across extrinsic than that across intrinsic muscle pairs (P = 0.0039). These findings indicate that the distribution of neural drive to multiple hand muscles is force independent and may reflect the anatomical properties or functional roles of hand muscle groups.

  11. Algorithms for a hand-held miniature x-ray fluorescence analytical instrument

    International Nuclear Information System (INIS)

    Elam, W.T.; Newman, D.; Ziemba, F.

    1998-01-01

    The purpose of this joint program was to provide technical assistance with the development of a Miniature X-ray Fluorescence (XRF) Analytical Instrument. This new XRF instrument is designed to overcome the weaknesses of spectrometers commercially available at the present time. Currently available XRF spectrometers (for a complete list see reference 1) convert spectral information to sample composition using the influence coefficients technique or the fundamental parameters method. They require either a standard sample with composition relatively close to the unknown or a detailed knowledge of the sample matrix. They also require a highly-trained operator and the results often depend on the capabilities of the operator. In addition, almost all existing field-portable, hand-held instruments use radioactive sources for excitation. Regulatory limits on such sources restrict them such that they can only provide relatively weak excitation. This limits all current hand-held XRF instruments to poor detection limits and/or long data collection times, in addition to the licensing requirements and disposal problems for radioactive sources. The new XRF instrument was developed jointly by Quantrad Sensor, Inc., the Naval Research Laboratory (NRL), and the Department of Energy (DOE). This report describes the analysis algorithms developed by NRL for the new instrument and the software which embodies them

  12. Unique identification code for medical fundus images using blood vessel pattern for tele-ophthalmology applications.

    Science.gov (United States)

    Singh, Anushikha; Dutta, Malay Kishore; Sharma, Dilip Kumar

    2016-10-01

    Identification of fundus images during transmission and storage in database for tele-ophthalmology applications is an important issue in modern era. The proposed work presents a novel accurate method for generation of unique identification code for identification of fundus images for tele-ophthalmology applications and storage in databases. Unlike existing methods of steganography and watermarking, this method does not tamper the medical image as nothing is embedded in this approach and there is no loss of medical information. Strategic combination of unique blood vessel pattern and patient ID is considered for generation of unique identification code for the digital fundus images. Segmented blood vessel pattern near the optic disc is strategically combined with patient ID for generation of a unique identification code for the image. The proposed method of medical image identification is tested on the publically available DRIVE and MESSIDOR database of fundus image and results are encouraging. Experimental results indicate the uniqueness of identification code and lossless recovery of patient identity from unique identification code for integrity verification of fundus images. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Smartphone Fundus Photography.

    Science.gov (United States)

    Nazari Khanamiri, Hossein; Nakatsuka, Austin; El-Annan, Jaafar

    2017-07-06

    Smartphone fundus photography is a simple technique to obtain ocular fundus pictures using a smartphone camera and a conventional handheld indirect ophthalmoscopy lens. This technique is indispensable when picture documentation of optic nerve, retina, and retinal vessels is necessary but a fundus camera is not available. The main advantage of this technique is the widespread availability of smartphones that allows documentation of macula and optic nerve changes in many settings that was not previously possible. Following the well-defined steps detailed here, such as proper alignment of the phone camera, handheld lens, and the patient's pupil, is the key for obtaining a clear retina picture with no interfering light reflections and aberrations. In this paper, the optical principles of indirect ophthalmoscopy and fundus photography will be reviewed first. Then, the step-by-step method to record a good quality retinal image using a smartphone will be explained.

  14. Maintaining radiation exposures as low as reasonably achievable (ALARA) for dental personnel operating portable hand-held x-ray equipment.

    Science.gov (United States)

    McGiff, Thomas J; Danforth, Robert A; Herschaft, Edward E

    2012-08-01

    Clinical experience indicates that newly available portable hand-held x-ray units provide advantages compared to traditional fixed properly installed and operated x-ray units in dental radiography. However, concern that hand-held x-ray units produce higher operator doses than fixed x-ray units has caused regulatory agencies to mandate requirements for use of hand-held units that go beyond those recommended by the manufacturer and can discourage the use of this technology. To assess the need for additional requirements, a hand-held x-ray unit and a pair of manikins were used to measure the dose to a simulated operator under two conditions: exposures made according to the manufacturer's recommendations and exposures made according to manufacturer's recommendation except for the removal of the x-ray unit's protective backscatter shield. Dose to the simulated operator was determined using an array of personal dosimeters and a pair of pressurized ion chambers. The results indicate that the dose to an operator of this equipment will be less than 0.6 mSv y⁻¹ if the device is used according to the manufacturer's recommendations. This suggests that doses to properly trained operators of well-designed, hand-held dental x-ray units will be below 1.0 mSv y⁻¹ (2% of the annual occupational dose limit) even if additional no additional operational requirements are established by regulatory agencies. This level of annual dose is similar to those reported as typical dental personnel using fixed x-ray units and appears to satisfy the ALARA principal for this class of occupational exposures.

  15. Neurosurgical hand-held optical coherence tomography (OCT) forward-viewing probe

    Science.gov (United States)

    Sun, Cuiru; Lee, Kenneth K. C.; Vuong, Barry; Cusimano, Michael; Brukson, Alexander; Mariampillai, Adrian; Standish, Beau A.; Yang, Victor X. D.

    2012-02-01

    A prototype neurosurgical hand-held optical coherence tomography (OCT) imaging probe has been developed to provide micron resolution cross-sectional images of subsurface tissue during open surgery. This new ergonomic hand-held probe has been designed based on our group's previous work on electrostatically driven optical fibers. It has been packaged into a catheter probe in the familiar form factor of the clinically accepted Bayonet shaped neurosurgical non-imaging Doppler ultrasound probes. The optical design was optimized using ZEMAX simulation. Optical properties of the probe were tested to yield an ~20 um spot size, 5 mm working distance and a 3.5 mm field of view. The scan frequency can be increased or decreased by changing the applied voltage. Typically a scan frequency of less than 60Hz is chosen to keep the applied voltage to less than 2000V. The axial resolution of the probe was ~15 um (in air) as determined by the OCT system. A custom-triggering methodology has been developed to provide continuous stable imaging, which is crucial for clinical utility. Feasibility of this probe, in combination with a 1310 nm swept source OCT system was tested and images are presented to highlight the usefulness of such a forward viewing handheld OCT imaging probe. Knowledge gained from this research will lay the foundation for developing new OCT technologies for endovascular management of cerebral aneurysms and transsphenoidal neuroendoscopic treatment of pituitary tumors.

  16. Clinical significance of non-mydriatic fundus photography in screening for preschool children ocular fundus disease

    Directory of Open Access Journals (Sweden)

    Jun Luo

    2014-06-01

    Full Text Available AIM: To observe the incidence of ocular fundus disease in preschool children examined by non-mydriatic fundus camera and evaluate its effectiveness compared with direct inspection shadow mirror. METHODS: Three thousand eight hundred and ninety-six preschool children from April 2012 to October 2013 were examined by Topcon TRC-NW300 color fluorescence fundus camera and direct inspection shadow mirror, and images were saved immediately. RESULTS: Detection rate of non-mydriatic fundus photography was higher than that of direct inspection shadow mirror. In 3 896 cases, 41 eyes were detected abnormal fundus accounting for 1.05%. The retinal myelinated nerve fibers, morning glory syndrome, retinitis pigmentosa, congenital retinoschisis were common, accounted for 24.39%, 21.95%, 14.63%, 12.20% respectively. The children eye diseases were often accompanied by abnormal vision(68.30%, ametropia(63.41%, strabismus(19.51%.CONCLUSION: Non-mydriatic fundus photography is a mydriatic method without medicine, so it is easy for preschool children to accept. Image results could directly display the fundus lesions. It shows important significance in the screening for preschool children eye diseases.

  17. A study of cladding technology on tube wall surface by a hand-held laser torch

    International Nuclear Information System (INIS)

    Terada, Takaya; Nishimura, Akihiko; Oka, Kiyoshi; Moriyama, Taku; Matsuda, Hiroyasu

    2015-01-01

    New maintenance technique was proposed using a hand-held laser torch for aging chemical plants and power plants. The hand-held laser torch was specially designed to be able to access limited tubular space in various cases. A composite-type optical fiberscope was composed of a center fiber for beam delivery and surrounded fibers for visible image delivery. Laser irradiation on a work pieces with the best accuracy of filler wire was carried out. And, we found that the optimized wire-feed speed was 2 mm/s in laser cladding. We succeeded to make a line clad on the inner wall of 23 mm tube. This technique was discussed to be applied to the maintenance for cracks or corrosions of tubes in various harsh environments. (author)

  18. Textureless Macula Swelling Detection with Multiple Retinal Fundus Images

    Energy Technology Data Exchange (ETDEWEB)

    Giancardo, Luca [ORNL; Meriaudeau, Fabrice [ORNL; Karnowski, Thomas Paul [ORNL; Tobin Jr, Kenneth William [ORNL; Grisan, Enrico [University of Padua, Padua, Italy; Favaro, Paolo [Heriot-Watt University, Edinburgh; Ruggeri, Alfredo [University of Padua, Padua, Italy; Chaum, Edward [University of Tennessee, Knoxville (UTK)

    2010-01-01

    Retinal fundus images acquired with non-mydriatic digital fundus cameras are a versatile tool for the diagnosis of various retinal diseases. Because of the ease of use of newer camera models and their relatively low cost, these cameras can be employed by operators with limited training for telemedicine or Point-of-Care applications. We propose a novel technique that uses uncalibrated multiple-view fundus images to analyse the swelling of the macula. This innovation enables the detection and quantitative measurement of swollen areas by remote ophthalmologists. This capability is not available with a single image and prone to error with stereo fundus cameras. We also present automatic algorithms to measure features from the reconstructed image which are useful in Point-of-Care automated diagnosis of early macular edema, e.g., before the appearance of exudation. The technique presented is divided into three parts: first, a preprocessing technique simultaneously enhances the dark microstructures of the macula and equalises the image; second, all available views are registered using non-morphological sparse features; finally, a dense pyramidal optical flow is calculated for all the images and statistically combined to build a naiveheight- map of the macula. Results are presented on three sets of synthetic images and two sets of real world images. These preliminary tests show the ability to infer a minimum swelling of 300 microns and to correlate the reconstruction with the swollen location.

  19. Fundus Photography in the 21st Century--A Review of Recent Technological Advances and Their Implications for Worldwide Healthcare.

    Science.gov (United States)

    Panwar, Nishtha; Huang, Philemon; Lee, Jiaying; Keane, Pearse A; Chuan, Tjin Swee; Richhariya, Ashutosh; Teoh, Stephen; Lim, Tock Han; Agrawal, Rupesh

    2016-03-01

    The introduction of fundus photography has impacted retinal imaging and retinal screening programs significantly. Fundus cameras play a vital role in addressing the cause of preventive blindness. More attention is being turned to developing countries, where infrastructure and access to healthcare are limited. One of the major limitations for tele-ophthalmology is restricted access to the office-based fundus camera. Recent advances in access to telecommunications coupled with introduction of portable cameras and smartphone-based fundus imaging systems have resulted in an exponential surge in available technologies for portable fundus photography. Retinal cameras in the near future would have to cater to these needs by featuring a low-cost, portable design with automated controls and digitalized images with Web-based transfer. In this review, we aim to highlight the advances of fundus photography for retinal screening as well as discuss the advantages, disadvantages, and implications of the various technologies that are currently available.

  20. Fundus Photography in the 21st Century—A Review of Recent Technological Advances and Their Implications for Worldwide Healthcare

    Science.gov (United States)

    Panwar, Nishtha; Huang, Philemon; Lee, Jiaying; Keane, Pearse A.; Chuan, Tjin Swee; Richhariya, Ashutosh; Teoh, Stephen; Lim, Tock Han

    2016-01-01

    Abstract Background: The introduction of fundus photography has impacted retinal imaging and retinal screening programs significantly. Literature Review: Fundus cameras play a vital role in addressing the cause of preventive blindness. More attention is being turned to developing countries, where infrastructure and access to healthcare are limited. One of the major limitations for tele-ophthalmology is restricted access to the office-based fundus camera. Results: Recent advances in access to telecommunications coupled with introduction of portable cameras and smartphone-based fundus imaging systems have resulted in an exponential surge in available technologies for portable fundus photography. Retinal cameras in the near future would have to cater to these needs by featuring a low-cost, portable design with automated controls and digitalized images with Web-based transfer. Conclusions: In this review, we aim to highlight the advances of fundus photography for retinal screening as well as discuss the advantages, disadvantages, and implications of the various technologies that are currently available. PMID:26308281

  1. Exploring field-of-view non-uniformities produced by a hand-held spectroradiometer

    Directory of Open Access Journals (Sweden)

    Tamir Caras

    2011-01-01

    Full Text Available The shape of a spectroradiometer’s field of view (FOV affects the way spectral measurements are acquired. Knowing this property is a prerequisite for the correct use of the spectrometer. If the substrate is heterogeneous, the ability to accurately know what is being measured depends on knowing the FOV location, shape, spectral and spatial sensitivity. The GER1500 is a hand-held spectrometer with a fixed lens light entry slit and has a laser guide that allows control over the target by positioning the entire unit. In the current study, the FOV of the GER1500 was mapped and analysed. The spectral and spatial non-uniformities of the FOV were examined and were found to be spectrally independent. The relationship between the FOV and the built-in laser guide was tested and found to have a linear displacement dependent on the distance to the target. This allows an accurate prediction of the actual FOV position. A correction method to improve the agreement between the expected and measured reflectance over heterogeneous targets was developed and validated. The methods described are applicable and may be of use with other hand-held spectroradiometers.

  2. Digital fundus image grading with the non-mydriatic Visucam(PRO NM) versus the FF450(plus) camera in diabetic retinopathy.

    Science.gov (United States)

    Neubauer, Aljoscha S; Rothschuh, Antje; Ulbig, Michael W; Blum, Marcus

    2008-03-01

    Grading diabetic retinopathy in clinical trials is frequently based on 7-field stereo photography of the fundus in diagnostic mydriasis. In terms of image quality, the FF450(plus) camera (Carl Zeiss Meditec AG, Jena, Germany) defines a high-quality reference. The aim of the study was to investigate if the fully digital fundus camera Visucam(PRO NM) could serve as an alternative in clinical trials requiring 7-field stereo photography. A total of 128 eyes of diabetes patients were enrolled in the randomized, controlled, prospective trial. Seven-field stereo photography was performed with the Visucam(PRO NM) and the FF450(plus) camera, in random order, both in diagnostic mydriasis. The resulting 256 image sets from the two camera systems were graded for retinopathy levels and image quality (on a scale of 1-5); both were anonymized and blinded to the image source. On FF450(plus) stereoscopic imaging, 20% of the patients had no or mild diabetic retinopathy (ETDRS level cameras regarding retinopathy levels (kappa 0.87) and macular oedema (kappa 0.80). In diagnostic mydriasis the image quality of the Visucam was graded slightly as better than that of the FF450(plus) (2.20 versus 2.41; p camera for applications and clinical trials requiring 7-field stereo photography.

  3. Gamma-ray detectors for intelligent, hand-held radiation monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1983-01-01

    Small radiation detectors based on HgI 2 , bismuth germanate (BGO), plastic, or NaI(Tl) detector materials were evaluated for use in small, lighweight radiation monitors. The two denser materials, HgI 2 and BGO, had poor resolution at low-energy and thus performed less well than NaI(Tl) in detecting low-energy gamma rays from bare, enriched uranium. The plastic scintillator, a Compton recoil detector, also performed less well at low gamma-ray energy. Two small NaI(Tl) detectors were suitable for detecting bare uranium and sheilded plutonium. One became part of a new lightweight hand-held monitor and the other found uses as a pole-mounted detector for monitoring hard-to-reach locations

  4. Application of smart phone and supporting set for fundus imaging in primary hospital of rural area

    Directory of Open Access Journals (Sweden)

    Yong-Feng Jing

    2018-01-01

    Full Text Available AIM: To describe the application of smart phone and supporting set for acquiring fundus images with slitlamp examination and non-contact lens in primary hospital of the rural area. METHODS: The supporting set for smart phone was purchased from taobao and securely connected to the ocular lens of slitlamp microscopy. The fundus photos were imaged with assistance of non-contact slitlamp lens from Volk. RESULTS: High quality images of various retinal diseases could be successfully taken with smart phone and supporting set by slitlamp examination. The fundus images were send to patients with Wechat as medical records or used for telconsultant. CONCLUSION: High resolution smart phones are wildly used nowadays and supporting sets are very accessible; thus high quality of images could be obtained with minimal cost in rural hospitals. The digital fundus images will be beneficial for medical record and rapid diagnosis with telconsultant.

  5. Fundus autofluorescence imaging of the white dot syndromes.

    Science.gov (United States)

    Yeh, Steven; Forooghian, Farzin; Wong, Wai T; Faia, Lisa J; Cukras, Catherine; Lew, Julie C; Wroblewski, Keith; Weichel, Eric D; Meyerle, Catherine B; Sen, Hatice Nida; Chew, Emily Y; Nussenblatt, Robert B

    2010-01-01

    To characterize the fundus autofluorescence (FAF) findings in patients with white dot syndromes (WDSs). Patients with WDSs underwent ophthalmic examination, fundus photography, fluorescein angiography, and FAF imaging. Patients were categorized as having no, minimal, or predominant foveal hypoautofluorescence. The severity of visual impairment was then correlated with the degree of foveal hypoautofluorescence. Fifty-five eyes of 28 patients with WDSs were evaluated. Visual acuities ranged from 20/12.5 to hand motions. Diagnoses included serpiginous choroidopathy (5 patients), birdshot retinochoroidopathy (10), multifocal choroiditis (8), relentless placoid chorioretinitis (1), presumed tuberculosis-associated serpiginouslike choroidopathy (1), acute posterior multifocal placoid pigment epitheliopathy (1), and acute zonal occult outer retinopathy (2). In active serpiginous choroidopathy, notable hyperautofluorescence in active disease distinguished it from the variegated FAF features of tuberculosis-associated serpiginouslike choroidopathy. The percentage of patients with visual acuity impairment of less than 20/40 differed among eyes with no, minimal, and predominant foveal hypoautofluorescence (P < .001). Patients with predominant foveal hypoautofluorescence demonstrated worse visual acuity than those with minimal or no foveal hypoautofluorescence (both P < .001). Fundus autofluorescence imaging is useful in the evaluation of the WDS. Visual acuity impairment is correlated with foveal hypoautofluorescence. Further studies are needed to evaluate the precise role of FAF imaging in the WDSs.

  6. Applying Hand-Held 3D Printing Technology to the Teaching of VSEPR Theory

    Science.gov (United States)

    Dean, Natalie L.; Ewan, Corrina; McIndoe, J. Scott

    2016-01-01

    The use of hand-held 3D printing technology provides a unique and engaging approach to learning VSEPR theory by enabling students to draw three-dimensional depictions of different molecular geometries, giving them an appreciation of the shapes of the building blocks of complex molecular structures. Students are provided with 3D printing pens and…

  7. Survey reveals public open to ban on hand-held cell phone use and texting.

    Science.gov (United States)

    2013-01-01

    A study performed by the Bureau of Transportation Statistics (BTS) reveals that the public is open to a ban on hand-held cell phone use while driving. The study is based on data from 2009s Omnibus Household Survey (OHS), which is administered by B...

  8. Fundus autofluorescence in serpiginouslike choroiditis.

    Science.gov (United States)

    Gupta, Amod; Bansal, Reema; Gupta, Vishali; Sharma, Aman

    2012-04-01

    To report the fundus autofluorescence characteristics in serpiginouslike choroiditis. Twenty-nine patients with presumed tubercular serpiginouslike choroiditis between November 2008 and January 2010 underwent fundus autofluorescence imaging during the acute stage and at regular intervals till the lesions healed. All patients received antitubercular therapy with oral corticosteroids. The autofluorescence images were compared with color fundus photography and fundus fluorescein angiography. The main outcome measure was fundus autofluorescence characteristics of lesions during the course of the disease. The pattern of fundus autofluorescence changed as the lesions evolved from the acute to the healed stage. In acute stage, the lesions showed an ill-defined halo of increased autofluorescence (hyperautofluorescence), giving it a diffuse, amorphous appearance (Stage I, acute). As the lesions began to heal, a thin rim of decreased autofluorescence (hypoautofluorescence) surrounded the lesion, defining its edges. The lesions showed predominantly hyperautofluorescence with stippled pattern (Stage II, subacute). With further healing, the hypoautofluorescence progressed and the lesion appeared predominantly hypoautofluorescent with stippled pattern (Stage III, nearly resolved). On complete healing, the lesions became uniformly hypoautofluorescent (Stage IV, completely resolved). Fundus autofluorescence highlighted the areas of disease activity and was a quick imaging tool for monitoring the course of lesions in serpiginouslike choroiditis.

  9. A Web-based telemedicine system for diabetic retinopathy screening using digital fundus photography.

    Science.gov (United States)

    Wei, Jack C; Valentino, Daniel J; Bell, Douglas S; Baker, Richard S

    2006-02-01

    The purpose was to design and implement a Web-based telemedicine system for diabetic retinopathy screening using digital fundus cameras and to make the software publicly available through Open Source release. The process of retinal imaging and case reviewing was modeled to optimize workflow and implement use of computer system. The Web-based system was built on Java Servlet and Java Server Pages (JSP) technologies. Apache Tomcat was chosen as the JSP engine, while MySQL was used as the main database and Laboratory of Neuro Imaging (LONI) Image Storage Architecture, from the LONI-UCLA, as the platform for image storage. For security, all data transmissions were carried over encrypted Internet connections such as Secure Socket Layer (SSL) and HyperText Transfer Protocol over SSL (HTTPS). User logins were required and access to patient data was logged for auditing. The system was deployed at Hubert H. Humphrey Comprehensive Health Center and Martin Luther King/Drew Medical Center of Los Angeles County Department of Health Services. Within 4 months, 1500 images of more than 650 patients were taken at Humphrey's Eye Clinic and successfully transferred to King/Drew's Department of Ophthalmology. This study demonstrates an effective architecture for remote diabetic retinopathy screening.

  10. Comparative Geometrical Investigations of Hand-Held Scanning Systems

    Science.gov (United States)

    Kersten, T. P.; Przybilla, H.-J.; Lindstaedt, M.; Tschirschwitz, F.; Misgaiski-Hass, M.

    2016-06-01

    An increasing number of hand-held scanning systems by different manufacturers are becoming available on the market. However, their geometrical performance is little-known to many users. Therefore the Laboratory for Photogrammetry & Laser Scanning of the HafenCity University Hamburg has carried out geometrical accuracy tests with the following systems in co-operation with the Bochum University of Applied Sciences (Laboratory for Photogrammetry) as well as the Humboldt University in Berlin (Institute for Computer Science): DOTProduct DPI-7, Artec Spider, Mantis Vision F5 SR, Kinect v1 + v2, Structure Sensor and Google's Project Tango. In the framework of these comparative investigations geometrically stable reference bodies were used. The appropriate reference data were acquired by measurement with two structured light projection systems (AICON smartSCAN and GOM ATOS I 2M). The comprehensive test results of the different test scenarios are presented and critically discussed in this contribution.

  11. A feasibility study to develop a diabetes prevention program for young adults with prediabetes using digital platforms and a hand held device

    Science.gov (United States)

    Cha, EunSeok; Kim, Kevin H.; Umpierrez, Guillermo; Dawkins, Colleen R.; Bello, Morenike K.; Lerner, Hannah; Narayan, K.M. Venkat; Dunbar, Sandra B.

    2014-01-01

    Purpose The purpose of the pilot study was to examine the feasibility and preliminary efficacy of an age-specific diabetes prevention program in young adults with prediabetes. Methods One group pretest-posttest design was conducted. The inclusion criteria were young adults age 18–29 years with prediabetes [either Impaird fasting glucose [IFG] (100–125 mg/dL), or an A1C of 5.7%–6.4%]. Fifteen participants were enrolled in this study. A technology based lifestyle coaching program focused on diet and physical activity and incorporating a hand-held device and digital platforms was developed and tested. Psychosocial factors (health literacy, illness perception, self-efficacy, therapeutic efficacy) based on social cognitive theory, changes in diet and physical activity, and cardiometabolic risk factors were assessed at baseline and week 12 after intervention. A paired-samples t-test was performed to examine changes between baseline and post-intervention on each psychosocial and physical variable. Results Participants (n= 13 completers) were mean age 24.4 yrs [SD: 2.2], 23.1% male, and 53.8% were African American. Overall, the participants were satisfied with the intervention (M = 4.15 on a 5-point Likert scale). Between pre and post testing, BMI and A1C decreased from 41.0 ±7.3 to 40.1±7.0 and 6.0% ± .5 to 5.6% ± .5, respectively, while fasting glucose did not significantly change (92.6±11 mg/dl to 97.6 ±14.3 mg/dl). Conclusion The intervention resulted in reduced A1C and a trend for decreased BMI in obese sedentary young adults with prediabetes after 12 weeks of intervention. Further study through a randomized clinical trial with a longer intervention period is warranted. PMID:24950683

  12. Ocular Fundus Photography as an Educational Tool.

    Science.gov (United States)

    Mackay, Devin D; Garza, Philip S

    2015-10-01

    The proficiency of nonophthalmologists with direct ophthalmoscopy is poor, which has prompted a search for alternative technologies to examine the ocular fundus. Although ocular fundus photography has existed for decades, its use has been traditionally restricted to ophthalmology clinical care settings and textbooks. Recent research has shown a role for nonmydriatic fundus photography in nonophthalmic settings, encouraging more widespread adoption of fundus photography technology. Recent studies have also affirmed the role of fundus photography as an adjunct or alternative to direct ophthalmoscopy in undergraduate medical education. In this review, the authors examine the use of ocular fundus photography as an educational tool and suggest future applications for this important technology. Novel applications of fundus photography as an educational tool have the potential to resurrect the dying art of funduscopy. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  13. Potential role of a new hand-held miniature gamma camera in performing minimally invasive parathyroidectomy

    Energy Technology Data Exchange (ETDEWEB)

    Ortega, Joaquin; Lledo, Salvador [University of Valencia, Clinic University Hospital, Department of Surgery, Valencia (Spain); Ferrer-Rebolleda, Jose [Clinic University Hospital, Department of Nuclear Medicine, Valencia (Spain); Cassinello, Norberto [Clinic University Hospital, Unit of Endocrinologic and Bariatric Surgery, Valencia (Spain)

    2007-02-15

    Sestamibi scans have increased the use of minimally invasive parathyroidectomy (MIP) to treat primary hyperparathyroidism (PHPT) when caused by a parathyroid single adenoma. The greatest concern for surgeons remains the proper identification of pathological glands in a limited surgical field. We have studied the usefulness of a new hand-held miniature gamma camera (MGC) when used intraoperatively to locate parathyroid adenomas. To our knowledge this is the first report published on this subject in the scientific literature. Five patients with PHPT secondary to a single adenoma, positively diagnosed by preoperative sestamibi scans, underwent a MIP. A gamma probe for radioguided surgery and the new hand-held MGC were used consecutively to locate the pathological glands. This new MGC has a module composed of a high-resolution interchangeable collimator and a CsI(Na) scintillating crystal. It has dimensions of around 15 cm x 8 cm x 9 cm and weighs 1 kg. The intraoperative assay of PTH (ioPTH) was used to confirm the complete resection of pathological tissue. All cases were operated on successfully by a MIP. The ioPTH confirmed the excision of all pathological tissues. The MGC proved its usefulness in all patients, even in a difficult case in which the first attempt with the gamma probe failed. In all cases it offered real-time accurate intraoperative images. The hand-held MGC is a useful instrument in MIP for PHPT. It may be used to complement the standard tools used to date, or may even replace them, at least in selected cases of single adenomas. (orig.)

  14. Potential role of a new hand-held miniature gamma camera in performing minimally invasive parathyroidectomy

    International Nuclear Information System (INIS)

    Ortega, Joaquin; Lledo, Salvador; Ferrer-Rebolleda, Jose; Cassinello, Norberto

    2007-01-01

    Sestamibi scans have increased the use of minimally invasive parathyroidectomy (MIP) to treat primary hyperparathyroidism (PHPT) when caused by a parathyroid single adenoma. The greatest concern for surgeons remains the proper identification of pathological glands in a limited surgical field. We have studied the usefulness of a new hand-held miniature gamma camera (MGC) when used intraoperatively to locate parathyroid adenomas. To our knowledge this is the first report published on this subject in the scientific literature. Five patients with PHPT secondary to a single adenoma, positively diagnosed by preoperative sestamibi scans, underwent a MIP. A gamma probe for radioguided surgery and the new hand-held MGC were used consecutively to locate the pathological glands. This new MGC has a module composed of a high-resolution interchangeable collimator and a CsI(Na) scintillating crystal. It has dimensions of around 15 cm x 8 cm x 9 cm and weighs 1 kg. The intraoperative assay of PTH (ioPTH) was used to confirm the complete resection of pathological tissue. All cases were operated on successfully by a MIP. The ioPTH confirmed the excision of all pathological tissues. The MGC proved its usefulness in all patients, even in a difficult case in which the first attempt with the gamma probe failed. In all cases it offered real-time accurate intraoperative images. The hand-held MGC is a useful instrument in MIP for PHPT. It may be used to complement the standard tools used to date, or may even replace them, at least in selected cases of single adenomas. (orig.)

  15. Hand-held cell phone use while driving legislation and observed driver behavior among population sub-groups in the United States

    OpenAIRE

    Rudisill, Toni M.; Zhu, Motao

    2017-01-01

    Abstract Background Cell phone use behaviors are known to vary across demographic sub-groups and geographic locations. This study examined whether universal hand-held calling while driving bans were associated with lower road-side observed hand-held cell phone conversations across drivers of different ages (16–24, 25–59, ≥60 years), sexes, races (White, African American, or other), ruralities (suburban, rural, or urban), and regions (Northeast, Midwest, South, and West). Methods Data from the...

  16. Fundus imaging with a nasal endoscope

    Directory of Open Access Journals (Sweden)

    P Mahesh Shanmugam

    2015-01-01

    Full Text Available Wide field fundus imaging is needed to diagnose, treat, and follow-up patients with retinal pathology. This is more applicable for pediatric patients as repeated evaluation is a challenge. The presently available imaging machines though provide high definition images, but carry the obvious disadvantages of either being costly or bulky or sometimes both, which limits its usage only to large centers. We hereby report a technique of fundus imaging using a nasal endoscope coupled with viscoelastic. A regular nasal endoscope with viscoelastic coupling was placed on the cornea to image the fundus of infants under general anesthesia. Wide angle fundus images of various fundus pathologies in infants could be obtained easily with readily available instruments and without the much financial investment for the institutes.

  17. COMPARATIVE GEOMETRICAL INVESTIGATIONS OF HAND-HELD SCANNING SYSTEMS

    Directory of Open Access Journals (Sweden)

    T. P. Kersten

    2016-06-01

    Full Text Available An increasing number of hand-held scanning systems by different manufacturers are becoming available on the market. However, their geometrical performance is little-known to many users. Therefore the Laboratory for Photogrammetry & Laser Scanning of the HafenCity University Hamburg has carried out geometrical accuracy tests with the following systems in co-operation with the Bochum University of Applied Sciences (Laboratory for Photogrammetry as well as the Humboldt University in Berlin (Institute for Computer Science: DOTProduct DPI-7, Artec Spider, Mantis Vision F5 SR, Kinect v1 + v2, Structure Sensor and Google’s Project Tango. In the framework of these comparative investigations geometrically stable reference bodies were used. The appropriate reference data were acquired by measurement with two structured light projection systems (AICON smartSCAN and GOM ATOS I 2M. The comprehensive test results of the different test scenarios are presented and critically discussed in this contribution.

  18. Infrared-laser-based fundus angiography

    Science.gov (United States)

    Klingbeil, Ulrich; Canter, Joseph M.; Lesiecki, Michael L.; Reichel, Elias

    1994-06-01

    Infrared fundus angiography, using the fluorescent dye indocyanine green (ICG), has shown great potential in delineating choroidal neovascularization (CNV) otherwise not detectable. A digital retinal imaging system containing a diode laser for illumination has been developed and optimized to perform high sensitivity ICG angiography. The system requires less power and generates less pseudo-fluorescence background than nonlaser devices. During clinical evaluation at three retinal centers more than 200 patients, the majority of which had age-related macular degeneration, were analyzed. Laser based ICG angiography was successful in outlining many of the ill-defined or obscure CNV as defined by fluorescein angiography. The procedure was not as successful with classic CNV. ICG angiograms were used to prepare and guide laser treatment.

  19. Evaluation of a focussed protocol for hand-held echocardiography and computer-assisted auscultation in detecting latent rheumatic heart disease in scholars.

    Science.gov (United States)

    Zühlke, Liesl J; Engel, Mark E; Nkepu, Simpiwe; Mayosi, Bongani M

    2016-08-01

    Introduction Echocardiography is the diagnostic test of choice for latent rheumatic heart disease. The utility of echocardiography for large-scale screening is limited by high cost, complex diagnostic protocols, and time to acquire multiple images. We evaluated the performance of a brief hand-held echocardiography protocol and computer-assisted auscultation in detecting latent rheumatic heart disease with or without pathological murmur. A total of 27 asymptomatic patients with latent rheumatic heart disease based on the World Heart Federation criteria and 66 healthy controls were examined by standard cardiac auscultation to detect pathological murmur. Hand-held echocardiography using a focussed protocol that utilises one view - that is, the parasternal long-axis view - and one measurement - that is, mitral regurgitant jet - and a computer-assisted auscultation utilising an automated decision tool were performed on all patients. The sensitivity and specificity of computer-assisted auscultation in latent rheumatic heart disease were 4% (95% CI 1.0-20.4%) and 93.7% (95% CI 84.5-98.3%), respectively. The sensitivity and specificity of the focussed hand-held echocardiography protocol for definite rheumatic heart disease were 92.3% (95% CI 63.9-99.8%) and 100%, respectively. The test reliability of hand-held echocardiography was 98.7% for definite and 94.7% for borderline disease, and the adjusted diagnostic odds ratios were 1041 and 263.9 for definite and borderline disease, respectively. Computer-assisted auscultation has extremely low sensitivity but high specificity for pathological murmur in latent rheumatic heart disease. Focussed hand-held echocardiography has fair sensitivity but high specificity and diagnostic utility for definite or borderline rheumatic heart disease in asymptomatic patients.

  20. Hand-held tidal breathing nasal nitric oxide measurement--a promising targeted case-finding tool for the diagnosis of primary ciliary dyskinesia

    DEFF Research Database (Denmark)

    Marthin, June Kehlet; Nielsen, Kim Gjerum

    2013-01-01

    BACKGROUND: Nasal nitric oxide (nNO) measurement is an established first line test in the work-up for primary ciliary dyskinesia (PCD). Tidal breathing nNO (TB-nNO) measurements require minimal cooperation and are potentially useful even in young children. Hand-held NO devices are becoming...... increasingly widespread for asthma management. Therefore, we chose to assess whether hand-held TB-nNO measurements reliably discriminate between PCD, and Healthy Subjects (HS) and included Cystic Fibrosis (CF) patients as a disease control group known to have intermediate nNO levels. METHODS: In this cross...... sectional, single centre, single occasion, proof-of-concept study in children and adults with PCD and CF, and in HS we compared feasibility, success rates, discriminatory capacity, repeatability and agreement between a hand-held electrochemical device equipped with a nNO software application sampling...

  1. Digital tomosynthesis of hand joints for arthritis assessment

    International Nuclear Information System (INIS)

    Duryea, J.; Dobbins, J.T. III; Lynch, J.A.

    2003-01-01

    The two principal forms of hand arthritis, rheumatoid arthritis (RA) and osteoarthritis (OA) have large clinical and economic costs. Radiography has been shown to be a useful tool to assess the condition of the disease. A hand radiograph, however, is a two-dimensional projection of a three-dimensional object. In this report we present the results of a study that applied digital tomosynthesis to hand radiography in order to extract three-dimensional outcome measures that should be more sensitive to arthritis progression. The study was performed using simulated projection radiographs created using micro computed tomography (μCT) and a set of five dry-bone hand skeletons. These simulated projection images were then reconstructed into tomographic slices using the matrix inversion tomosynthesis (MITS) algorithm. The accuracy of the tomosynthesis reconstruction was evaluated by comparing the reconstructed images to a gold standard created using the μCT data. A parameter from image registration science, normalized mutual information, provided a quantifiable figure of merit. This study examined the effects of source displacement, number of reconstructed planes, number of acquisitions, noise added to the gray scale images, and errors in the location of a fiducial marker. We also optimized the reconstruction as a function of two variables k and α, that controlled the mixing of MITS with conventional shift-and-add tomosynthesis. A study using hand delineated joint margins demonstrated that MITS images provided a better measurement of average joint space width. We found good agreement between the MITS slices and the true planes. Both joint margins and trabecular structure were visible and the reconstructed slices showed additional structures not visible with the standard projection image. Using hand-delineated joint margins we compared the average joint space width of the gold standard slices to the MITS and projection images. A root-mean square deviation (RMSD), calculated

  2. Genetics Home Reference: fundus albipunctatus

    Science.gov (United States)

    ... Lorenz B, Sander B, Larsen M, Eckstein C, Rosenberg T. Lack of autofluorescence in fundus albipunctatus associated ... Preising M, Lorenz B, Sander B, Larsen M, Rosenberg T. Fundus albipunctatus associated with compound heterozygous mutations ...

  3. Film-screen vs. digital radiography in rheumatoid arthritis of the hand. An ROC analysis

    International Nuclear Information System (INIS)

    Jonsson, A.; Borg, A.; Hannesson, P.; Herrlin, K.; Jonsson, K.; Sloth, M.; Pettersson, H.

    1994-01-01

    In a prospective investigation the diagnostic accuracy of filmscreen and digital radiography in rheumatoid arthritis of hands was compared. Seventy hands of 36 patients with established rheumatoid arthritis were included in the study. Each of 11 joints in every hand was evaluated regarding the following radiologic parameters: soft tissue swelling, joint space narrowing, erosions and periarticular osteopenia. The digital images were obtained with storage phosphor image plates and evaluated in 2 forms; as digital hard-copy on film and on a monitor of an interactive workstation. The digital images had a resolution of either 3.33 or 5.0 lp/mm. ROC curves were constructed and comparing the area under the curves no significant difference was found between the 3 different imaging forms in either resolution group for soft tissue swelling, joint space narrowing and erosions. The film-screen image evaluation of periarticular osteopenia was significantly better than the digital hard-copy one in the 3.33 lp/mm resolution group, but no significant difference was found in the 5.0 lp/mm group. These results support the view that currently available digital systems are capable of adequate diagnostic performance. (orig.)

  4. Rapid and automatic chemical identification of the medicinal flower buds of Lonicera plants by the benchtop and hand-held Fourier transform infrared spectroscopy

    Science.gov (United States)

    Chen, Jianbo; Guo, Baolin; Yan, Rui; Sun, Suqin; Zhou, Qun

    2017-07-01

    With the utilization of the hand-held equipment, Fourier transform infrared (FT-IR) spectroscopy is a promising analytical technique to minimize the time cost for the chemical identification of herbal materials. This research examines the feasibility of the hand-held FT-IR spectrometer for the on-site testing of herbal materials, using Lonicerae Japonicae Flos (LJF) and Lonicerae Flos (LF) as examples. Correlation-based linear discriminant models for LJF and LF are established based on the benchtop and hand-held FT-IR instruments. The benchtop FT-IR models can exactly recognize all articles of LJF and LF. Although a few LF articles are misjudged at the sub-class level, the hand-held FT-IR models are able to exactly discriminate LJF and LF. As a direct and label-free analytical technique, FT-IR spectroscopy has great potential in the rapid and automatic chemical identification of herbal materials either in laboratories or in fields. This is helpful to prevent the spread and use of adulterated herbal materials in time.

  5. An evaluation of fundus photography and fundus autofluorescence in the diagnosis of cuticular drusen

    DEFF Research Database (Denmark)

    Høeg, Tracy B; Moldow, Birgitte; Klein, Ronald

    2016-01-01

    PURPOSE: To examine non-mydriatic fundus photography (FP) and fundus autofluorescence (FAF) as alternative non-invasive imaging modalities to fluorescein angiography (FA) in the detection of cuticular drusen (CD). METHODS: Among 2953 adults from the Danish Rural Eye Study (DRES) with gradable FP...

  6. Hand-held indirect calorimeter offers advantages compared with prediction equations, in a group of overweight women, to determine resting energy expenditures and estimated total energy expenditures during research screening.

    Science.gov (United States)

    Spears, Karen E; Kim, Hyunsook; Behall, Kay M; Conway, Joan M

    2009-05-01

    To compare standardized prediction equations to a hand-held indirect calorimeter in estimating resting energy and total energy requirements in overweight women. Resting energy expenditure (REE) was measured by hand-held indirect calorimeter and calculated by prediction equations Harris-Benedict, Mifflin-St Jeor, World Health Organization/Food and Agriculture Organization/United Nations University (WHO), and Dietary Reference Intakes (DRI). Physical activity level, assessed by questionnaire, was used to estimate total energy expenditure (TEE). Subjects (n=39) were female nonsmokers older than 25 years of age with body mass index more than 25. Repeated measures analysis of variance, Bland-Altman plot, and fitted regression line of difference. A difference within +/-10% of two methods indicated agreement. Significant proportional bias was present between hand-held indirect calorimeter and prediction equations for REE and TEE (Pvalues and underestimated at higher values. Mean differences (+/-standard error) for REE and TEE between hand-held indirect calorimeter and Harris-Benedict were -5.98+/-46.7 kcal/day (P=0.90) and 21.40+/-75.7 kcal/day (P=0.78); between hand-held indirect calorimeter and Mifflin-St Jeor were 69.93+/-46.7 kcal/day (P=0.14) and 116.44+/-75.9 kcal/day (P=0.13); between hand-held indirect calorimeter and WHO were -22.03+/-48.4 kcal/day (P=0.65) and -15.8+/-77.9 kcal/day (P=0.84); and between hand-held indirect calorimeter and DRI were 39.65+/-47.4 kcal/day (P=0.41) and 56.36+/-85.5 kcal/day (P=0.51). Less than 50% of predictive equation values were within +/-10% of hand-held indirect calorimeter values, indicating poor agreement. A significant discrepancy between predicted and measured energy expenditure was observed. Further evaluation of hand-held indirect calorimeter research screening is needed.

  7. Automated detection of fundus photographic red lesions in diabetic retinopathy.

    Science.gov (United States)

    Larsen, Michael; Godt, Jannik; Larsen, Nicolai; Lund-Andersen, Henrik; Sjølie, Anne Katrin; Agardh, Elisabet; Kalm, Helle; Grunkin, Michael; Owens, David R

    2003-02-01

    To compare a fundus image-analysis algorithm for automated detection of hemorrhages and microaneurysms with visual detection of retinopathy in patients with diabetes. Four hundred fundus photographs (35-mm color transparencies) were obtained in 200 eyes of 100 patients with diabetes who were randomly selected from the Welsh Community Diabetic Retinopathy Study. A gold standard reference was defined by classifying each patient as having or not having diabetic retinopathy based on overall visual grading of the digitized transparencies. A single-lesion visual grading was made independently, comprising meticulous outlining of all single lesions in all photographs and used to develop the automated red lesion detection system. A comparison of visual and automated single-lesion detection in replicating the overall visual grading was then performed. Automated red lesion detection demonstrated a specificity of 71.4% and a resulting sensitivity of 96.7% in detecting diabetic retinopathy when applied at a tentative threshold setting for use in diabetic retinopathy screening. The accuracy of 79% could be raised to 85% by adjustment of a single user-supplied parameter determining the balance between the screening priorities, for which a considerable range of options was demonstrated by the receiver-operating characteristic (area under the curve 90.3%). The agreement of automated lesion detection with overall visual grading (0.659) was comparable to the mean agreement of six ophthalmologists (0.648). Detection of diabetic retinopathy by automated detection of single fundus lesions can be achieved with a performance comparable to that of experienced ophthalmologists. The results warrant further investigation of automated fundus image analysis as a tool for diabetic retinopathy screening.

  8. Design of hand held RID's monitoring system based on embedded system

    International Nuclear Information System (INIS)

    Wang Hongwei; Wei Yixiang

    2008-01-01

    In this paper we introduce the design of monitoring system for the hand held radionuclide identification device (RID), constructed under the embedded operating system of WinCE. At first, we introduce the design of hardware and software platform, and following is the major part of technical view of the software system, including the driver development, P/Invoke mechanism to call the C/C++ subroutines, multi-thread technology. In the experimental hardware platform, we have developed a front-end monitoring system for portable device targeted nuclide identification and orientation. It's a full-featured and flexible system, with the functions of data acquisition, radioactivity locating, data import and export, etc. (authors)

  9. Temporary Nerve Block at Selected Digits Revealed Hand Motor Deficits in Grasping Tasks

    Directory of Open Access Journals (Sweden)

    Aude Carteron

    2016-11-01

    Full Text Available Peripheral sensory feedback plays a crucial role in ensuring correct motor execution throughout hand grasp control. Previous studies utilized local anesthesia to deprive somatosensory feedback in the digits or hand, observations included sensorimotor deficits at both corticospinal and peripheral levels. However, the questions of how the disturbed and intact sensory input integrate and interact with each other to assist the motor program execution, and whether the motor coordination based on motor output variability between affected and non-affected elements (e.g., digits becomes interfered by the local sensory deficiency, have not been answered. The current study aims to investigate the effect of peripheral deafferentation through digital nerve blocks at selective digits on motor performance and motor coordination in grasp control. Our results suggested that the absence of somatosensory information induced motor deficits in hand grasp control, as evidenced by reduced maximal force production ability in both local and non-local digits, impairment of force and moment control during object lift and hold, and attenuated motor synergies in stabilizing task performance variables, namely the tangential force and moment of force. These findings implied that individual sensory input is shared across all the digits and the disturbed signal from local sensory channel(s has a more comprehensive impact on the process of the motor output execution in the sensorimotor integration process. Additionally, a feedback control mechanism with a sensation-based component resides in the formation process for the motor covariation structure.

  10. The grey fovea sign of macular oedema or subfoveal fluid on non-stereoscopic fundus photographs

    DEFF Research Database (Denmark)

    Hasler, Pascal W; Soliman, Wael; Sander, Birgit

    2017-01-01

    PURPOSE: To describe the grey fovea sign of fovea-involving macular oedema or subretinal fluid accumulation in red-free fundus photography. METHODS: A test set of 91 digital fundus photographs of good quality from 100 consecutive eyes in 72 patients with diabetic retinopathy or central serous...... chorioretinopathy was composed by one of the investigators and evaluated by four masked observers. The photographs were graded as to whether a normal dark fovea was present or absent. The reference method was foveal thickness measurement using optical coherence tomography (OCT). RESULTS: Eyes graded as having...... a grey fovea on fundus photographs (n = 67) had a median foveal thickness of 279 μm (interquartile range 130 μm), whereas eyes graded as having a normal dark fovea (n = 24) had a median foveal thickness of 238 μm (interquartile range 44.5 μm, p = 0.025). CONCLUSION: The absence of a dark fovea on red...

  11. Functional and cosmetic outcome of single-digit ray amputation in hand.

    Science.gov (United States)

    Bhat, A K; Acharya, A M; Narayanakurup, J K; Kumar, B; Nagpal, P S; Kamath, A

    2017-12-01

    To assess patient satisfaction, functional and cosmetic outcomes of single-digit ray amputation in hand and identify factors that might affect the outcome. Forty-five patients who underwent ray amputation were evaluated, 37 males and eight females whose mean age was 36.6 years ranging between 15 and 67 years. Twenty-eight patients had dominant hand involvement. Twenty-one patients underwent primary ray amputation, and 24 patients had secondary ray amputation. Eight out of the 23 patients with central digit injuries underwent transposition. Grip strength, pinch strength, tactile sensibility and functional evaluation using Result Assessment Scale (RAS) and DASH score were analysed. Cosmetic assessment was performed using visual analogue scale (VAS) for cosmesis. Median time of assessment after surgery was 20 months. Average loss of grip strength and pinch strength was found to be 43.3 and 33.6%, respectively. Average RAS score was 3.75. Median DASH score was 23.4. Eighty-three percentage of patients had excellent or good cosmesis on the VAS. Transposition causes significant increase in DASH scores for central digit ray amputations but was cosmetically superior. Middle finger ray amputation had the maximum loss of grip strength, and index finger ray amputation had greater loss of pinch strength. Affection of neighbouring digits caused greater grip and pinch loss, and a higher DASH score. Primary ray resection decreased the total disability and eliminated the costs of a second procedure. Following ray amputation, one can predict an approximate 43.3% loss of grip strength and 33.6% loss of pinch strength. The patients can be counselled regarding the expected time off from work, amount of disability and complications after a single-digit ray amputation. Majority of the patients can return to the same occupation after a period of dedicated hand therapy. Therapeutic, Level III.

  12. Hand-Held Sunphotometers for High School Student Construction and Measuring Aerosol Optical Thickness

    Science.gov (United States)

    Almonor, Linda; Baldwin, C.; Craig, R.; Johnson, L. P.

    2000-01-01

    Science education is taking the teaching of science from a traditional (lecture) approach to a multidimensional sense-making approach which allows teachers to support students by providing exploratory experiences. Using projects is one way of providing students with opportunities to observe and participate in sense-making activity. We created a learning environment that fostered inquiry-based learning. Students were engaged in a variety of Inquiry activities that enabled them to work in cooperative planning teams where respect for each other was encouraged and their ability to grasp, transform and transfer information was enhanced. Summer, 1998: An air pollution workshop was conducted for high school students in the Medgar Evers College/Middle College High School Liberty Partnership Summer Program. Students learned the basics of meteorology: structure and composition of the atmosphere and the processes that cause weather. The highlight of this workshop was the building of hand-held sunphotometers, which measure the intensity of the sunlight striking the Earth. Summer, 1999: high school students conducted a research project which measured the mass and size of ambient particulates and enhanced our ability to observe through land based measurements changes in the optical depth of ambient aerosols over Brooklyn. Students used hand held Sunphotometers to collect data over a two week period and entered it into the NASA GISS database by way of the internet.

  13. Extra-oral dental radiography for disaster victims using a flat panel X-ray detector and a hand-held X-ray generator.

    Science.gov (United States)

    Ohtani, M; Oshima, T; Mimasaka, S

    2017-12-01

    Forensic odontologists commonly incise the skin for post-mortem dental examinations when it is difficult to open the victim's mouth. However, it is prohibited by law to incise dead bodies without permission in Japan. Therefore, we attempted using extra-oral dental radiography, using a digital X-ray equipment with rechargeable batteries, to overcome this restriction. A phantom was placed in the prone position on a table, and three plain dental radiographs were used per case: "lateral oblique radiographs" for left and right posterior teeth and a "contact radiograph" for anterior teeth were taken using a flat panel X-ray detector and a hand-held X-ray generator. The resolving power of the images was measured by a resolution test chart, and the scattered X-ray dose was measured using an ionization chamber-type survey meter. The resolving power of the flat panel X-ray detector was 3.0 lp/mm, which was less than that of intra-oral dental methods, but the three extra-oral plain dental radiographs provided the overall dental information from outside of the mouth, and this approach was less time-consuming. In addition, the higher dose of scattered X-rays was laterally distributed, but the dose per case was much less than that of intra-oral dental radiographs. Extra-oral plain dental radiography can be used for disaster victim identification by dental methods even when it is difficult to open the mouth. Portable and rechargeable devices, such as a flat panel X-ray detector and a hand-held X-ray generator, are convenient to bring and use anywhere, even at a disaster scene lacking electricity and water.

  14. Surgical amputation of the digit: an investigation into the technical variations among hand surgeons.

    Science.gov (United States)

    Li, Andrew; Meunier, Matthew; Rennekampff, Hans-Oliver; Tenenhaus, Mayer

    2013-01-01

    Digital injuries are common and frequently complicate occupational hazards and trauma. The management of these injuries often necessitates digital amputation, and a variety of different amputation techniques are advocated and employed by hand surgeons. In this survey study, we investigate the variation in technical detail among a group of hand surgeons when performing digital amputations, specifically the preferred management of the residual articular cartilage, transected nerves, and phalangeal contouring. We reviewed the literature on techniques in digital amputation and created a 7-question survey that targeted controversial issues within this specific topic. We then sent this survey electronically to the members of the American Society for Surgery of the Hand and reviewed the responses of the respondents (n = 592, 20%). There was a mixed response regarding whether or not to remove the articular cartilage when disarticulating, nearly a 50% split between the respondents. Most would perform a "pull and resect" technique for transected nerves. Phalangeal contouring was generally agreed upon, though the technique in doing so varied from performing condylectomies, to bony contouring only, to some combination of both. We detected a substantial variation in technique among our group of hand surgeons regarding the treatment of articular cartilage and the method of phalangeal contouring. There was more consensus regarding the treatment of transected nerve. It is interesting that to date, the aforementioned issues in digital amputation have not been critically evaluated by definitive and well-controlled studies.

  15. Effect of data compression on diagnostic accuracy in digital hand and chest radiography

    Science.gov (United States)

    Sayre, James W.; Aberle, Denise R.; Boechat, Maria I.; Hall, Theodore R.; Huang, H. K.; Ho, Bruce K. T.; Kashfian, Payam; Rahbar, Guita

    1992-05-01

    Image compression is essential to handle a large volume of digital images including CT, MR, CR, and digitized films in a digital radiology operation. The full-frame bit allocation using the cosine transform technique developed during the last few years has been proven to be an excellent irreversible image compression method. This paper describes the effect of using the hardware compression module on diagnostic accuracy in hand radiographs with subperiosteal resorption and chest radiographs with interstitial disease. Receiver operating characteristic analysis using 71 hand radiographs and 52 chest radiographs with five observers each demonstrates that there is no statistical significant difference in diagnostic accuracy between the original films and the compressed images with a compression ratio as high as 20:1.

  16. Precise intraoperative location of gastrointestinal bleeding with a hand-held counter. Work in progress

    International Nuclear Information System (INIS)

    Williamson, M.R.; Boyd, C.M.; McGuire, E.L.

    1986-01-01

    The nuclear medicine bleeding scan is frequently insufficient to locate sites of bleeding precisely, in spite of its great sensitivity. A small, hand-held Geiger-Mueller counter, placed directly on exposed intestine in the operating room, enables precise location of the probable bleeding site. In three patients, the technique allowed a minimal amount of intestine to be resected, distinguished between large- and small-intestinal hemorrhage, and eliminated other foci as sites of bleeding.A

  17. A Method of Drusen Measurement Based on the Geometry of Fundus Reflectance

    Directory of Open Access Journals (Sweden)

    Barbazetto Irene

    2003-04-01

    Full Text Available Abstract Background The hallmarks of age-related macular degeneration, the leading cause of blindness in the developed world, are the subretinal deposits known as drusen. Drusen identification and measurement play a key role in clinical studies of this disease. Current manual methods of drusen measurement are laborious and subjective. Our purpose was to expedite clinical research with an accurate, reliable digital method. Methods An interactive semi-automated procedure was developed to level the macular background reflectance for the purpose of morphometric analysis of drusen. 12 color fundus photographs of patients with age-related macular degeneration and drusen were analyzed. After digitizing the photographs, the underlying background pattern in the green channel was leveled by an algorithm based on the elliptically concentric geometry of the reflectance in the normal macula: the gray scale values of all structures within defined elliptical boundaries were raised sequentially until a uniform background was obtained. Segmentation of drusen and area measurements in the central and middle subfields (1000 μm and 3000 μm diameters were performed by uniform thresholds. Two observers using this interactive semi-automated software measured each image digitally. The mean digital measurements were compared to independent stereo fundus gradings by two expert graders (stereo Grader 1 estimated the drusen percentage in each of the 24 regions as falling into one of four standard broad ranges; stereo Grader 2 estimated drusen percentages in 1% to 5% intervals. Results The mean digital area measurements had a median standard deviation of 1.9%. The mean digital area measurements agreed with stereo Grader 1 in 22/24 cases. The 95% limits of agreement between the mean digital area measurements and the more precise stereo gradings of Grader 2 were -6.4 % to +6.8 % in the central subfield and -6.0 % to +4.5 % in the middle subfield. The mean absolute

  18. Vascular changes of the hand in professional baseball players with emphasis on digital ischemia in catchers.

    Science.gov (United States)

    Ginn, T Adam; Smith, Adam M; Snyder, Jon R; Koman, L Andrew; Smith, Beth P; Rushing, Julia

    2005-07-01

    Repetitive trauma to the hand is a concern for baseball players. The present study investigated the effects of repetitive trauma and the prevalence of microvascular pathological changes in the hands of minor league professional baseball players. In contrast to previous investigators, we documented the presence of abnormalities in younger, asymptomatic individuals. Thirty-six baseball players on active minor league rosters underwent a history and physical examination of both hands as well as additional specialized tests, including Doppler ultrasound, a timed Allen test, determination of digital brachial pressure indices, and ring sizing of fingers. Data were compared between gloved hands and throwing hands, hitters and nonhitters, and players at four different positions (catcher [nine subjects], outfielder [seven subjects], infielder [five subjects], and pitcher [fifteen subjects]). Digital brachial indices in the ring fingers of the gloved (p healthy professional baseball players in all positions, with a significantly higher prevalence in catchers, prior to the development of clinically important ischemia. Repetitive trauma resulting from the impact of the baseball also leads to digital hypertrophy in the index finger of the gloved hand of catchers. Gloves currently used by professional catchers do not adequately protect the hand from repetitive trauma.

  19. Fundus Autofluorescence Features of Optic Disc Pit Related ...

    African Journals Online (AJOL)

    chorioretinopathy, retina telangiectasia and diffuse and macula retina dystrophies.[1,3‑8] These features give useful clinical and prognostic information, making FAF a desired day‑to‑day clinical tool. Fundus autoflorescence signals can be detected using 3 different systems, the Delori's fundus. Fundus Autofluorescence ...

  20. Portable Hand-Held Electrochemical Sensor for the Transuranics

    Energy Technology Data Exchange (ETDEWEB)

    Dale D. Russell, William B. Knowlton, Ph.D.; Russel Hertzog, Ph.D

    2005-11-25

    sensitive detector for uranium. Millimeter scale electrodes, operated by a hand-held instrument assembled in this lab and operated in the voltammetric mode, were transported to the DOE-Nevada test site (Las Vegas, NV) where field detection and quantitation of plutonium, uranium, and a mixture of these two elements was also demonstrated. Several probe designs were prepared, built and tested including probes with movable protective windows. A miniature, battery powered potentiostat was designed, built and demonstrated for use in a hand-held field portable instrument. This work was performed largely by undergraduates who gained valuable research experience, and many of them have continued on to graduate schools. In addition, they all gained exposure to and appreciation for national security research, in particular non-proliferation research. Four graduate students participated and one earned the MS degree on this project.

  1. Teaching Digital Citizenship in a Global Academy

    Science.gov (United States)

    Pescetta, Marxan

    2011-01-01

    As technology continues to change the way society communicates, teachers need to prepare their students for digital literacy and competencies in their adulthood. Specific training is necessary for educators in the appropriate and effective methods for incorporating technologies such as smart phones and hand-held devices. Teachers, who work in…

  2. Dupuytren’s disease digital radius IV right hand and carpal tunnel syndrome on ipsilateral hand

    Directory of Open Access Journals (Sweden)

    Teona Sebe Ioana

    2015-11-01

    Full Text Available Dupuytren’s contracture is a fibroproliferative disease whose etiology and pathophysiology are unclear and controversial. It is a connective tissue disorder, which takes part in the palmar’s fibromatosis category and has common characteristics with the healing process. Dupuytren’s disease is characterized by the flexion contracture of the hand due to palmar and digital aponevrosis. It generally affects the 4th digital radius, followed by the 5th one. Without surgery, it leads to functional impotence of those digital rays and/or hand. It is associated with other diseases and situational conditions like Peyronie’s disease, the Lederhose disease (plantar fibromatosis, Garrod’s digital knuckle-pads, diabetes, epilepsy, alcoholism, micro traumatisms, stenosing tenosynovitis and not the least with carpal tunnel syndrome. The carpal tunnel syndrome is a peripheral neuropathy with the incarceration of the median nerve at the ARC level, expressed clinically by sensory and motor disturbances in the distribution territory of the median nerve, which cause functional limitations of daily activities of the patient. After the failure of the nonsurgical treatment or the appearance of the motor deficit, is established the open or endoscopic surgical treatment with the release of the median nerve. Postoperative recovery in both diseases is crucial to the functionality of the affected upper limb and to the quality of the patient’s life. The patient, a 61 years old man, admitted to the clinic for the functional impotence of the right hand, for the permanent flexion contracture of the metacarpophalangeal joint (MCP and proximal interphalangeal joint (PIP of the 4th finger with extension deficit, for the damage of the thumb pulp clamp of the 4th finger, for nocturnal paresthesia of fingers I-III and pain that radiates into the fingertips. After clinical, paraclinical, imagistic and electrical investigations, surgery is practiced partial aponevrectomy

  3. A new approach for the screening of carotid lesions: a 'fast-track' method with the use of new generation hand-held ultrasound devices.

    Science.gov (United States)

    Aboyans, V; Lacroix, P; Jeannicot, A; Guilloux, J; Bertin, F; Laskar, M

    2004-09-01

    We assessed the usefulness of fast-track neck sonography with a new-generation hand-held ultrasound scanner in the detection of > or =60% carotid stenosis. Patients with a past history of atherosclerotic disease or presence of risk factors were enrolled. All had fast-track carotid screening with a hand-held ultrasound scanner. Initial assessment was performed with our quick imaging protocol. A second examiner performed a conventional complete carotid duplex as gold-standard. We enrolled 197 consecutive patients with a mean age of 67 years (range 35-94). A carotid stenosis >60% was detected in 13 cases (6%). The sensitivity, specificity, positive and negative predictive value of fast-track sonography was 100%, 64%, 17% and 100%, respectively. Concomitant power Doppler imaging during the fast-track method did not improve accuracy. The use of a fast-track method with a hand-held ultrasound device can reduce the number of unnecessary carotid Duplex and enhance the screening efficiency without missing significant carotid stenoses.

  4. 21 CFR 886.1395 - Diagnostic Hruby fundus lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic Hruby fundus lens. 886.1395 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1395 Diagnostic Hruby fundus lens. (a) Identification. A diagnostic Hruby fundus lens is a device that is a 55 diopter lens intended for use in the...

  5. An integrated portable hand-held analyser for real-time isothermal nucleic acid amplification

    International Nuclear Information System (INIS)

    Smith, Matthew C.; Steimle, George; Ivanov, Stan; Holly, Mark; Fries, David P.

    2007-01-01

    A compact hand-held heated fluorometric instrument for performing real-time isothermal nucleic acid amplification and detection is described. The optoelectronic instrument combines a Printed Circuit Board/Micro Electro Mechanical Systems (PCB/MEMS) reaction detection/chamber containing an integrated resistive heater with attached miniature LED light source and photo-detector and a disposable glass waveguide capillary to enable a mini-fluorometer. The fluorometer is fabricated and assembled in planar geometry, rolled into a tubular format and packaged with custom control electronics to form the hand-held reactor. Positive or negative results for each reaction are displayed to the user using an LED interface. Reaction data is stored in FLASH memory for retrieval via an in-built USB connection. Operating on one disposable 3 V lithium battery >12, 60 min reactions can be performed. Maximum dimensions of the system are 150 mm (h) x 48 mm (d) x 40 mm (w), the total instrument weight (with battery) is 140 g. The system produces comparable results to laboratory instrumentation when performing a real-time nucleic acid sequence-based amplification (NASBA) reaction, and also displayed comparable precision, accuracy and resolution to laboratory-based real-time nucleic acid amplification instrumentation. A good linear response (R 2 = 0.948) to fluorescein gradients ranging from 0.5 to 10 μM was also obtained from the instrument indicating that it may be utilized for other fluorometric assays. This instrument enables an inexpensive, compact approach to in-field genetic screening, providing results comparable to laboratory equipment with rapid user feedback as to the status of the reaction

  6. An integrated portable hand-held analyser for real-time isothermal nucleic acid amplification

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Matthew C. [College of Marine Science, University of South Florida, St Petersburg, FL (United States)], E-mail: msmith@marine.usf.edu; Steimle, George; Ivanov, Stan; Holly, Mark; Fries, David P. [College of Marine Science, University of South Florida, St Petersburg, FL (United States)

    2007-08-29

    A compact hand-held heated fluorometric instrument for performing real-time isothermal nucleic acid amplification and detection is described. The optoelectronic instrument combines a Printed Circuit Board/Micro Electro Mechanical Systems (PCB/MEMS) reaction detection/chamber containing an integrated resistive heater with attached miniature LED light source and photo-detector and a disposable glass waveguide capillary to enable a mini-fluorometer. The fluorometer is fabricated and assembled in planar geometry, rolled into a tubular format and packaged with custom control electronics to form the hand-held reactor. Positive or negative results for each reaction are displayed to the user using an LED interface. Reaction data is stored in FLASH memory for retrieval via an in-built USB connection. Operating on one disposable 3 V lithium battery >12, 60 min reactions can be performed. Maximum dimensions of the system are 150 mm (h) x 48 mm (d) x 40 mm (w), the total instrument weight (with battery) is 140 g. The system produces comparable results to laboratory instrumentation when performing a real-time nucleic acid sequence-based amplification (NASBA) reaction, and also displayed comparable precision, accuracy and resolution to laboratory-based real-time nucleic acid amplification instrumentation. A good linear response (R{sup 2} = 0.948) to fluorescein gradients ranging from 0.5 to 10 {mu}M was also obtained from the instrument indicating that it may be utilized for other fluorometric assays. This instrument enables an inexpensive, compact approach to in-field genetic screening, providing results comparable to laboratory equipment with rapid user feedback as to the status of the reaction.

  7. Cost effective spectral sensor solutions for hand held and field applications

    Science.gov (United States)

    Reetz, Edgar; Correns, Martin; Notni, Gunther

    2015-05-01

    Optical spectroscopy is without doubt one of the most important non-contact measurement principles. It is used in a wide range of applications from bio-medical to industrial fields. One recent trend is to miniaturize spectral sensors to address new areas of application. The most common spectral sensor type is based on diffraction gratings, while other types are based on micro mechanical systems (MEMS) or filter technologies. The authors represent the opinion that there is a potentially wide spread field of applications for spectrometers, but the market limits the range of applications since they cannot keep up with targeted cost requirements for consumer products. The present article explains an alternative approach for miniature multichannel spectrometer to enhance robustness for hand held field applications at a cost efficient price point.

  8. Semi-automated retinal vessel analysis in nonmydriatic fundus photography.

    Science.gov (United States)

    Schuster, Alexander Karl-Georg; Fischer, Joachim Ernst; Vossmerbaeumer, Urs

    2014-02-01

    Funduscopic assessment of the retinal vessels may be used to assess the health status of microcirculation and as a component in the evaluation of cardiovascular risk factors. Typically, the evaluation is restricted to morphological appreciation without strict quantification. Our purpose was to develop and validate a software tool for semi-automated quantitative analysis of retinal vasculature in nonmydriatic fundus photography. matlab software was used to develop a semi-automated image recognition and analysis tool for the determination of the arterial-venous (A/V) ratio in the central vessel equivalent on 45° digital fundus photographs. Validity and reproducibility of the results were ascertained using nonmydriatic photographs of 50 eyes from 25 subjects recorded from a 3DOCT device (Topcon Corp.). Two hundred and thirty-three eyes of 121 healthy subjects were evaluated to define normative values. A software tool was developed using image thresholds for vessel recognition and vessel width calculation in a semi-automated three-step procedure: vessel recognition on the photograph and artery/vein designation, width measurement and calculation of central retinal vessel equivalents. Mean vessel recognition rate was 78%, vessel class designation rate 75% and reproducibility between 0.78 and 0.91. Mean A/V ratio was 0.84. Application on a healthy norm cohort showed high congruence with prior published manual methods. Processing time per image was one minute. Quantitative geometrical assessment of the retinal vasculature may be performed in a semi-automated manner using dedicated software tools. Yielding reproducible numerical data within a short time leap, this may contribute additional value to mere morphological estimates in the clinical evaluation of fundus photographs. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  9. Hip- and knee-strength assessments using a hand-held dynamometer with external belt-fixation are inter-tester reliable

    DEFF Research Database (Denmark)

    Thorborg, Kristian; Bandholm, Thomas; Hölmich, Per

    2013-01-01

    PURPOSE: In football, ice-hockey, and track and field, injuries have been predicted, and hip- and knee-strength deficits quantified using hand-held dynamometry (HHD). However, systematic bias exists when testers of different sex and strength perform the measurements. Belt-fixation of the dynamome...

  10. Quantitative fundus autofluorescence in recessive Stargardt disease.

    Science.gov (United States)

    Burke, Tomas R; Duncker, Tobias; Woods, Russell L; Greenberg, Jonathan P; Zernant, Jana; Tsang, Stephen H; Smith, R Theodore; Allikmets, Rando; Sparrow, Janet R; Delori, François C

    2014-05-01

    To quantify fundus autofluorescence (qAF) in patients with recessive Stargardt disease (STGD1). A total of 42 STGD1 patients (ages: 7-52 years) with at least one confirmed disease-associated ABCA4 mutation were studied. Fundus AF images (488-nm excitation) were acquired with a confocal scanning laser ophthalmoscope equipped with an internal fluorescent reference to account for variable laser power and detector sensitivity. The gray levels (GLs) of each image were calibrated to the reference, zero GL, magnification, and normative optical media density to yield qAF. Texture factor (TF) was calculated to characterize inhomogeneities in the AF image and patients were assigned to the phenotypes of Fishman I through III. Quantified fundus autofluorescence in 36 of 42 patients and TF in 27 of 42 patients were above normal limits for age. Young patients exhibited the relatively highest qAF, with levels up to 8-fold higher than healthy eyes. Quantified fundus autofluorescence and TF were higher in Fishman II and III than Fishman I, who had higher qAF and TF than healthy eyes. Patients carrying the G1916E mutation had lower qAF and TF than most other patients, even in the presence of a second allele associated with severe disease. Quantified fundus autofluorescence is an indirect approach to measuring RPE lipofuscin in vivo. We report that ABCA4 mutations cause significantly elevated qAF, consistent with previous reports indicating that increased RPE lipofuscin is a hallmark of STGD1. Even when qualitative differences in fundus AF images are not evident, qAF can elucidate phenotypic variation. Quantified fundus autofluorescence will serve to establish genotype-phenotype correlations and as an outcome measure in clinical trials.

  11. Quantitative Fundus Autofluorescence in Recessive Stargardt Disease

    Science.gov (United States)

    Burke, Tomas R.; Duncker, Tobias; Woods, Russell L.; Greenberg, Jonathan P.; Zernant, Jana; Tsang, Stephen H.; Smith, R. Theodore; Allikmets, Rando; Sparrow, Janet R.; Delori, François C.

    2014-01-01

    Purpose. To quantify fundus autofluorescence (qAF) in patients with recessive Stargardt disease (STGD1). Methods. A total of 42 STGD1 patients (ages: 7–52 years) with at least one confirmed disease-associated ABCA4 mutation were studied. Fundus AF images (488-nm excitation) were acquired with a confocal scanning laser ophthalmoscope equipped with an internal fluorescent reference to account for variable laser power and detector sensitivity. The gray levels (GLs) of each image were calibrated to the reference, zero GL, magnification, and normative optical media density to yield qAF. Texture factor (TF) was calculated to characterize inhomogeneities in the AF image and patients were assigned to the phenotypes of Fishman I through III. Results. Quantified fundus autofluorescence in 36 of 42 patients and TF in 27 of 42 patients were above normal limits for age. Young patients exhibited the relatively highest qAF, with levels up to 8-fold higher than healthy eyes. Quantified fundus autofluorescence and TF were higher in Fishman II and III than Fishman I, who had higher qAF and TF than healthy eyes. Patients carrying the G1916E mutation had lower qAF and TF than most other patients, even in the presence of a second allele associated with severe disease. Conclusions. Quantified fundus autofluorescence is an indirect approach to measuring RPE lipofuscin in vivo. We report that ABCA4 mutations cause significantly elevated qAF, consistent with previous reports indicating that increased RPE lipofuscin is a hallmark of STGD1. Even when qualitative differences in fundus AF images are not evident, qAF can elucidate phenotypic variation. Quantified fundus autofluorescence will serve to establish genotype-phenotype correlations and as an outcome measure in clinical trials. PMID:24677105

  12. Direction-Sensitive Hand-Held Gamma-Ray Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mukhopadhyay, S.

    2012-10-04

    A novel, light-weight, hand-held gamma-ray detector with directional sensitivity is being designed. The detector uses a set of multiple rings around two cylindrical surfaces, which provides precise location of two interaction points on two concentric cylindrical planes, wherefrom the source location can be traced back by back projection and/or Compton imaging technique. The detectors are 2.0 × 2.0 mm europium-doped strontium iodide (SrI2:Eu2+) crystals, whose light output has been measured to exceed 120,000 photons/MeV, making it one of the brightest scintillators in existence. The crystal’s energy resolution, less than 3% at 662 keV, is also excellent, and the response is highly linear over a wide range of gamma-ray energies. The emission of SrI2:Eu2+ is well matched to both photo-multiplier tubes and blue-enhanced silicon photodiodes. The solid-state photomultipliers used in this design (each 2.0 × 2.0 mm) are arrays of active pixel sensors (avalanche photodiodes driven beyond their breakdown voltage in reverse bias); each pixel acts as a binary photon detector, and their summed output is an analog representation of the total photon energy, while the individual pixel accurately defines the point of interaction. A simple back-projection algorithm involving cone-surface mapping is being modeled. The back projection for an event cone is a conical surface defining the possible location of the source. The cone axis is the straight line passing through the first and second interaction points.

  13. Comparison of Color Fundus Photography, Infrared Fundus Photography, and Optical Coherence Tomography in Detecting Retinal Hamartoma in Patients with Tuberous Sclerosis Complex.

    Science.gov (United States)

    Bai, Da-Yong; Wang, Xu; Zhao, Jun-Yang; Li, Li; Gao, Jun; Wang, Ning-Li

    2016-05-20

    A sensitive method is required to detect retinal hamartomas in patients with tuberous sclerosis complex (TSC). The aim of the present study was to compare the color fundus photography, infrared imaging (IFG), and optical coherence tomography (OCT) in the detection rate of retinal hamartoma in patients with TSC. This study included 11 patients (22 eyes) with TSC, who underwent color fundus photography, IFG, and spectral-domain OCT to detect retinal hamartomas. TSC1 and TSC2RESULTS: The mean age of the 11 patients was 8.0 ± 2.1 years. The mean spherical equivalent was -0.55 ± 1.42 D by autorefraction with cycloplegia. In 11 patients (22 eyes), OCT, infrared fundus photography, and color fundus photography revealed 26, 18, and 9 hamartomas, respectively. The predominant hamartoma was type I (55.6%). All the hamartomas that detected by color fundus photography or IFG can be detected by OCT. Among the methods of color fundus photography, IFG, and OCT, the OCT has higher detection rate for retinal hamartoma in TSC patients; therefore, OCT might be promising for the clinical diagnosis of TSC.

  14. Effects of a new mild shampoo for preventing hair loss in Asian by a simple hand-held phototrichogram technique.

    Science.gov (United States)

    Baek, J H; Lee, S Y; Yoo, M; Park, W-S; Lee, S J; Boo, Y C; Koh, J-S

    2011-12-01

    This study was conducted to evaluate the effects of a commercially available shampoo in Korean subjects with alopecia using a simple hand-held phototrichogram technique. Forty-four subjects with alopecia were enrolled and forty subjects continued for 16 weeks. In the test group, total hair counts increased significantly at weeks 8 and 16, and the number of shedding hair significantly decreased at week 16. Terminal hair counts significantly increased at week 8. In the control group, hair thickness and the number of vellus hairs significantly decreased at week 16. The number of total hairs significantly increased in the test group than in the control group at weeks 8 and 16. The number of shedding hairs significantly decreased in the test group than in the control group at week 16. Visual assessment using clinical digital images showed that the number of total hairs appeared to increase although there was no statistical significance. In this study, it was found that the test shampoo could prevent hair loss. © 2011 DERMAPRO Co Ltd. ICS © 2011 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  15. Visual Search and Target Cueing: A Comparison of Head-Mounted Versus Hand-Held Displays on the Allocation of Visual Attention

    National Research Council Canada - National Science Library

    Yeh, Michelle; Wickens, Christopher D

    1998-01-01

    We conducted a study to examine the effects of target cueing and conformality with a hand-held or head-mounted display to determine their effects on visual search tasks requiring focused and divided attention...

  16. Simple Multiplexing Hand-Held Control Unit

    Science.gov (United States)

    Hannaford, Blake

    1989-01-01

    Multiplexer consists of series of resistors, each shunted by single-pole, single-throw switch. User operates switches by pressing buttons or squeezing triggers. Prototype includes three switches operated successfully in over 200 hours of system operations. Number of switches accommodated determined by signal-to-noise ratio of current source, noise induced in control unit and cable, and number of bits in output of analog-to-digital converter. Because many computer-contolled robots have extra analog-to-digital channels, such multiplexer added at little extra cost.

  17. Intra-operative ultrasound hand-held strain imaging for the visualization of ablations produced in the liver with a toroidal HIFU transducer: first in vivo results

    Energy Technology Data Exchange (ETDEWEB)

    Chenot, J; Melodelima, D; N' Djin, W A; Souchon, Remi; Rivoire, M; Chapelon, J Y, E-mail: jeremy.chenot@inserm.f [Inserm, U556, Lyon, F-69003 (France)

    2010-06-07

    The use of hand-held ultrasound strain imaging for the intra-operative real-time visualization of HIFU (high-intensity focused ultrasound) ablations produced in the liver by a toroidal transducer was investigated. A linear 12 MHz ultrasound imaging probe was used to obtain radiofrequency signals. Using a fast cross-correlation algorithm, strain images were calculated and displayed at 60 frames s{sup -1}, allowing the use of hand-held strain imaging intra-operatively. Fourteen HIFU lesions were produced in four pigs. Intra-operative strain imaging of HIFU ablations in the liver was feasible owing to the high frame rate. The correlation between dimensions measured on gross pathology and dimensions measured on B-mode images and on strain images were R = 0.72 and R = 0.94 respectively. The contrast between ablated and non-ablated tissue was significantly higher (p < 0.05) in the strain images (22 dB) than in the B-mode images (9 dB). Strain images allowed equivalent or improved definition of ablated regions when compared with B-mode images. Real-time intra-operative hand-held strain imaging seems to be a promising complement to conventional B-mode imaging for the guidance of HIFU ablations produced in the liver during an open procedure. These results support that hand-held strain imaging outperforms conventional B-mode ultrasound and could potentially be used for the assessment of thermal therapies.

  18. Evaluating two methods of digital photography in retinopathy screening

    Directory of Open Access Journals (Sweden)

    Li Chen

    2018-02-01

    Full Text Available AIM:To evaluate the advantages of non-mydriatic fundus photography(NMFCSand mydriatic fundus photography(MFCSas eye-bottom screening and diagnosis methods in compared with gold standard fluorescein fundus angiography(FFA. METHODS: A total of 276 patients which involved in Chronic Diabetes Management Achieves within 4 streets of Pudong District Shanghai, were enrolled for diabetic retinopathy(DRexamination including NMFCS, MFCS and FFA. These DR examinations were proceeded after vision, slit-lamp and dioptroscopy tests, and reported by professionals. For those with suspicious fundus diseases, we would make appointments with specialist for further treatment. RESULTS: A total of 1104 colorful fundus images, and 1056 images(95.65%could be used to analyze. There were 408 appreciable images, 116 basically appreciable images and 28 unusable images in 552 NMFCS images. In addition, there were 432 appreciable images, 100 basically appreciable images and 20 unusable images in 552 MFCS images. There was no significant differences between NMFCS and MFCS(P>0.05. Compared with FFA with DRⅠ as the critical value, the specificity of digital photography for NMFCS was 95.71%, the sensitivity was 93.56%; however, MFCS are 95.43% and 98.02%. There was no statistically significant difference between the two screening methods(P>0.05. Compared with FFA with DRⅡ as the critical value, the specificity of digital photography for NMFCS was 95.35% and the sensitivity was 93.44%; however, for MFCS were 95.81% and 98.36%. There was no statistically significant difference between the two screening methods(P>0.05. CONCLUSION: Both NMFCS and MFCS could be used for the diagnosis and screening for eye diseases. NMFCS is easier and faster for digital photography, which is suitable for mass screening. MFCS is more likely to provide detailed information about the follow-up of the disease.

  19. Interoperative fundus image and report sharing in compliance with integrating the healthcare enterprise conformance and web access todigital imaging and communication in medicinepersistent object protocol

    Directory of Open Access Journals (Sweden)

    Hui-Qun Wu

    2013-12-01

    Full Text Available AIM:To address issues in interoperability between different fundus image systems, we proposed a web eye-picture archiving and communication system (PACS framework in conformance with digital imaging and communication in medicine (DICOM and health level 7 (HL7 protocol to realize fundus images and reports sharing and communication through internet.METHODS: Firstly, a telemedicine-based eye care work flow was established based on integrating the healthcare enterprise (IHE Eye Care technical framework. Then, a browser/server architecture eye-PACS system was established in conformance with the web access to DICOM persistent object (WADO protocol, which contains three tiers.RESULTS:In any client system installed with web browser, clinicians could log in the eye-PACS to observe fundus images and reports. Multipurpose internet mail extensions (MIME type of a structured report is saved as pdf/html with reference link to relevant fundus image using the WADO syntax could provide enough information for clinicians. Some functions provided by open-source Oviyam could be used to query, zoom, move, measure, view DICOM fundus images.CONCLUSION:Such web eye-PACS in compliance to WADO protocol could be used to store and communicate fundus images and reports, therefore is of great significance for teleophthalmology.

  20. Grading of 7-standard field fundus photography for diagosis of diabetic retinopathy%七方位彩色眼底照像法对糖尿病视网膜病变的诊断价值

    Institute of Scientific and Technical Information of China (English)

    赵琳; 刘瑜玲; 鹿欣荣; 钱芳; 张敏

    2009-01-01

    Objeetive To evaluate the ability ofmydriatic single-field 50°digital fundus photography and mydriatic 7-standard field fundus photography to detect diabetic retinopathy (DR)in patients with diabetic mellitus (DM)compared with fluorescein fundus angiography (FFA).Methods A Total of 164 diabetic patients attending a hospital-based screening clinic were recruited.Mydriatie single-field 50°digital fundus photography,mydriatic 7-standard field ETDRS fundus photography and FFA were performed using a Zeiss ff450 plus IR fundus camera.Grading of diabetic retinopathy was carried out by two ophthalmologists with diabetic retinopathy international clinical classification.The results were evaluated and compared respectively.ResuitsMydriatic single-field 50°digital fundus photography and FFA demonstrated moderate agreement (k=0.488).Mydriatic 7-standard field fundns photography and FFA demonstrated near perfect agreement (k=0.873).Conclusion Mydriatic 7-standard field fundus photography is an effective and clinically viable technique to screen for diabetic retinopathy among a diabetic population,Mydriatic single-field 50°digital fundus photography moderate.%目的 筛选经济、简便、有效地糖尿病视网膜病变检查法.方法 分别采用散瞳50度眼底后极部彩色照像法、美国早期糖尿病性视网膜病变治疗研究小组确立的散瞳30度眼底七方位彩色照像法和FFA法对164例(308只眼)糖尿病患者进行检查,由有经验的眼底医生按照糖尿病视网膜病变国际临床分类法对图片进行分析给出分期,对三种方法所得结果进行比较.结果 散瞳50度眼底后极部彩色照像法和FFA法在DR诊断分期中一致性一般(k=0.488),七方位彩色眼底照像法和FFA法在DR诊断分期中有比较好的一致性(k=0.873).结论 七方位彩色眼底照像法可作为糖尿病视网膜病变筛查和指导治疗的一种比较可靠的方法,而散瞳50度眼底后极部彩色照像法的可靠性一般.

  1. Inter-Rater Reliability of Cyclotorsion Measurements Using Fundus Photography.

    Science.gov (United States)

    Dysli, Muriel; Kanku, Madeleine; Traber, Ghislaine L

    2018-04-01

    The foveo-papillary angle (FPA) on fundus photographs is the accepted standard for the measurement of ocular cyclotorsion. We assessed the inter-rater reliability of this method in healthy subjects and in patients with trochlear nerve palsies. In this methodological study, fundus photographs of healthy subjects and of patients with trochlear nerve palsies were made with a fundus camera (Zeiss Fundus Camera FF 450 plus, Jena, Germany). Three independent observers measured the FPA on the fundus photographs of all subjects in synedra View (synedra View 16, Version 16.0.0.11, Innsbruck, Austria). One hundred and four eyes of 52 subjects (26 healthy controls and 26 patients) were assessed. The mean FPA of the healthy controls was 5.80 degrees (°) [± 0.44 standard error of the mean (SEM)] compared to 11.55° (± 0.80 SEM) for patients with trochlear nerve palsies. The inter-rater reliability of all measured FPAs showed an intraclass correlation coefficient (ICC) of 0.98 (95% CI 0.97 - 0.98). The inter-rater reliability of objective cyclotorsion measurements using fundus photographs was very high. Georg Thieme Verlag KG Stuttgart · New York.

  2. Hand and digital ischemia due to arteriosclerosis and thromboembolization in young adults: pathologic features with clinical correlations.

    Science.gov (United States)

    Guarda, L A; Borrero, J L

    1990-11-01

    Twenty young adult patients with hand and digital ischemia were found to have obstructive arterial disease. All patients were surgically explored, and the occluded vessels were resected and by-passed. Eighteen patients had obstruction at the level of the distal ulnar artery and palmar arch, and 12 had obstruction of the common digital and digital proper arteries. Occlusive arteriosclerotic lesions were found in all patients; these lesions were characterized by prominent fibromuscular intimal plaques with superimposed thrombosis. Six patients had also thromboembolism to distal digital vessels. Vasculitis, calcifications, cholesterol deposits, and atheromatous emboli were not observed. Five patients had transmural neovascularization of the lesions in a similar manner to that described in coronary artery lesions. Obstructive lesions due to fibromuscular intimal proliferation with associated thrombosis and/or distal thromboembolization affecting arteries of hands and digits appear to be an important lesion that can affect young patients.

  3. The Spectrum of Fundus Autofluorescence Findings in Birdshot Chorioretinopathy

    Directory of Open Access Journals (Sweden)

    GianPaolo Giuliari

    2009-01-01

    Full Text Available Objective. To describe the diverse patterns observed with the use of autofluorescence fundus photography (FAF in patients with Birdshot chorioretinopathy (BSCR. Methods. A chart review of patients with BSCR seen at the Massachusetts Eye Research and Surgery Institution, who had autofluorescence fundus photography. The data obtained included age, gender, presence of the HLA-A29 haplotype, and current treatment. Results. Eighteen eyes with HLA-A29 associated BSCR were included. Four eyes presented with active inflammation. Correspondence of the lesions noted in the colour fundus photograph was observed in 3 eyes which were more easily identified with the FAF. Fifteen eyes had fundus lesions more numerous and evident in the FAF than in the colour fundus photograph. Conclusion. Because FAF testing provides valuable insight into the metabolic state of the PR/RPE-complex, it may serve as a useful noninvasive assessment tool in patients with posterior uveitis in which the outer retina-RPE-choriocapillaries-complex is involved.

  4. A hand-held sensor for analyses of local distributions of magnetic fields and losses

    CERN Document Server

    Krismanic, G; Baumgartinger, N

    2000-01-01

    The paper describes a novel sensor for non-destructive analyses of local field and loss distributions in laminated soft magnetic cores, such as transformer cores. It was designed for rapid information on comparative local degrees of inhomogeneity, e.g., for the estimation of local building factors. Similar to a magnifying glass with handle, the compact hand-held sensor contains extremely sharp needle electrodes for the detection of the induction vector B as well as double-field coils for the vector H. Losses P are derived from the Poynting law. Applied to inner -- or also outer -- core regions, the sensor yields instantaneous computer displays of local H, B, and P.

  5. Automated classification and quantitative analysis of arterial and venous vessels in fundus images

    Science.gov (United States)

    Alam, Minhaj; Son, Taeyoon; Toslak, Devrim; Lim, Jennifer I.; Yao, Xincheng

    2018-02-01

    It is known that retinopathies may affect arteries and veins differently. Therefore, reliable differentiation of arteries and veins is essential for computer-aided analysis of fundus images. The purpose of this study is to validate one automated method for robust classification of arteries and veins (A-V) in digital fundus images. We combine optical density ratio (ODR) analysis and blood vessel tracking algorithm to classify arteries and veins. A matched filtering method is used to enhance retinal blood vessels. Bottom hat filtering and global thresholding are used to segment the vessel and skeleton individual blood vessels. The vessel tracking algorithm is used to locate the optic disk and to identify source nodes of blood vessels in optic disk area. Each node can be identified as vein or artery using ODR information. Using the source nodes as starting point, the whole vessel trace is then tracked and classified as vein or artery using vessel curvature and angle information. 50 color fundus images from diabetic retinopathy patients were used to test the algorithm. Sensitivity, specificity, and accuracy metrics were measured to assess the validity of the proposed classification method compared to ground truths created by two independent observers. The algorithm demonstrated 97.52% accuracy in identifying blood vessels as vein or artery. A quantitative analysis upon A-V classification showed that average A-V ratio of width for NPDR subjects with hypertension decreased significantly (43.13%).

  6. Quality Enhancement and Nerve Fibre Layer Artefacts Removal in Retina Fundus Images by Off Axis Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Giancardo, Luca [ORNL; Meriaudeau, Fabrice [ORNL; Karnowski, Thomas Paul [ORNL; Li, Yaquin [University of Tennessee, Knoxville (UTK); Tobin Jr, Kenneth William [ORNL; Chaum, Edward [University of Tennessee, Knoxville (UTK)

    2011-01-01

    Retinal fundus images acquired with non-mydriatic digital fundus cameras are a versatile tool for the diagnosis of various retinal diseases. Because of the ease of use of newer camera models and their relative low cost, these cameras are employed worldwide by retina specialists to diagnose diabetic retinopathy and other degenerative diseases. Even with relative ease of use, the images produced by these systems sometimes suffer from reflectance artefacts mainly due to the nerve fibre layer (NFL) or other camera lens related reflections. We propose a technique that employs multiple fundus images acquired from the same patient to obtain a single higher quality image without these reflectance artefacts. The removal of bright artefacts, and particularly of NFL reflectance, can have great benefits for the reduction of false positives in the detection of retinal lesions such as exudate, drusens and cotton wool spots by automatic systems or manual inspection. If enough redundant information is provided by the multiple images, this technique also compensates for a suboptimal illumination. The fundus images are acquired in straightforward but unorthodox manner, i.e. the stare point of the patient is changed between each shot but the camera is kept fixed. Between each shot, the apparent shape and position of all the retinal structures that do not exhibit isotropic reflectance (e.g. bright artefacts) change. This physical effect is exploited by our algorithm in order to extract the pixels belonging to the inner layers of the retina, hence obtaining a single artefacts-free image.

  7. Non-mydriatic, wide field, fundus video camera

    Science.gov (United States)

    Hoeher, Bernhard; Voigtmann, Peter; Michelson, Georg; Schmauss, Bernhard

    2014-02-01

    We describe a method we call "stripe field imaging" that is capable of capturing wide field color fundus videos and images of the human eye at pupil sizes of 2mm. This means that it can be used with a non-dilated pupil even with bright ambient light. We realized a mobile demonstrator to prove the method and we could acquire color fundus videos of subjects successfully. We designed the demonstrator as a low-cost device consisting of mass market components to show that there is no major additional technical outlay to realize the improvements we propose. The technical core idea of our method is breaking the rotational symmetry in the optical design that is given in many conventional fundus cameras. By this measure we could extend the possible field of view (FOV) at a pupil size of 2mm from a circular field with 20° in diameter to a square field with 68° by 18° in size. We acquired a fundus video while the subject was slightly touching and releasing the lid. The resulting video showed changes at vessels in the region of the papilla and a change of the paleness of the papilla.

  8. Reliability of measuring hip abductor strength following total knee arthroplasty using a hand-held dynamometer.

    Science.gov (United States)

    Schache, Margaret B; McClelland, Jodie A; Webster, Kate E

    2016-01-01

    To investigate the test-retest reliability of measuring hip abductor strength in patients with total knee arthroplasty (TKA) using a hand-held dynamometer (HHD) with two different types of resistance: belt and manual resistance. Test-retest reliability of 30 subjects (17 female, 13 male, 71.9 ± 7.4 years old), 9.2 ± 2.7 days post TKA was measured using belt and therapist resistance. Retest reliability was calculated with intra-class coefficients (ICC3,1) and 95% confidence intervals (CI) for both the group average and the individual scores. A paired t-test assessed whether a difference existed between the belt and therapist methods of resistance. ICCs were 0.82 and 0.80 for the belt and therapist resisted methods, respectively. Hip abductor strength increases of 8 N (14%) for belt resisted and 14 N (17%) for therapist resisted measurements of the group average exceeded the 95% CI and may represent real change. For individuals, hip abductor strength increases of 33 N (72%) (belt resisted) and 57 N (79%) (therapist resisted) could be interpreted as real change. Hip abductor strength can be reliably measured using HHD in the clinical setting with the described protocol. Belt resistance demonstrated slightly higher test-retest reliability. Reliable measurement of hip abductor muscle strength in patients with TKA is important to ensure deficiencies are addressed in rehabilitation programs and function is maximized. Hip abductor strength can be reliably measured with a hand-held dynamometer in the clinical setting using manual or belt resistance.

  9. Fundus Autofluorescence and Photoreceptor Cell Rosettes in Mouse Models

    Science.gov (United States)

    Flynn, Erin; Ueda, Keiko; Auran, Emily; Sullivan, Jack M.; Sparrow, Janet R.

    2014-01-01

    Purpose. This study was conducted to study correlations among fundus autofluorescence (AF), RPE lipofuscin accumulation, and photoreceptor cell degeneration and to investigate the structural basis of fundus AF spots. Methods. Fundus AF images (55° lens; 488-nm excitation) and spectral-domain optical coherence tomography (SD-OCT) scans were acquired in pigmented Rdh8−/−/Abca4−/− mice (ages 1–9 months) with a confocal scanning laser ophthalmoscope (cSLO). For quantitative fundus AF (qAF), gray levels (GLs) were calibrated to an internal fluorescence reference. Retinal bisretinoids were measured by quantitative HPLC. Histometric analysis of outer nuclear layer (ONL) thicknesses was performed, and cryostat sections of retina were examined by fluorescence microscopy. Results. Quantified A2E and qAF intensities increased until age 4 months in the Rdh8−/−/Abca4−/− mice. The A2E levels declined after 4 months of age, but qAF intensity values continued to rise. The decline in A2E levels in the Rdh8−/−/Abca4−/− mice paralleled reduced photoreceptor cell viability as reflected in ONL thinning. Hyperautofluorescent puncta in fundus AF images corresponded to photoreceptor cell rosettes in SD-OCT images and histological sections stained with hematoxylin and eosin. The inner segment/outer segment–containing core of the rosette emitted an autofluorescence detected by fluorescence microscopy. Conclusions. When neural retina is disordered, AF from photoreceptor cells can contribute to noninvasive fundus AF images. Hyperautofluorescent puncta in fundus AF images are attributable, in at least some cases, to photoreceptor cell rosettes. PMID:25015357

  10. Fundus Otoflöresans

    OpenAIRE

    ŞERMET, Figen

    2017-01-01

    Fundus otoflöresans görüntüleme, retina hastalıklarında patofizyolojik mekanizmaların anlaşılması, tanı, fenotipgenotipkorelasyonu, hastalık progresyonunu etkileyen faktörlerin belirlenmesi ve tedavi monitörizasyonunda yararlı birgörüntüleme yöntemidir. Fundus otoflöresans görüntüleme birçok hastalığın tanı ve takibinde kullanılabilir. Bu derlemedefundus otoflöresans görüntülemenin retina hastalıkları ve ayırıcı tanısında önemli rol oynadığı hastalıklar klinik olgufotoğraflarıyla da desteklen...

  11. Characterization of a high performance ultra-thin heat pipe cooling module for mobile hand held electronic devices

    Science.gov (United States)

    Ahamed, Mohammad Shahed; Saito, Yuji; Mashiko, Koichi; Mochizuki, Masataka

    2017-11-01

    In recent years, heat pipes have been widely used in various hand held mobile electronic devices such as smart phones, tablet PCs, digital cameras. With the development of technology these devices have different user friendly features and applications; which require very high clock speeds of the processor. In general, a high clock speed generates a lot of heat, which needs to be spreaded or removed to eliminate the hot spot on the processor surface. However, it is a challenging task to achieve proper cooling of such electronic devices mentioned above because of their confined spaces and concentrated heat sources. Regarding this challenge, we introduced an ultra-thin heat pipe; this heat pipe consists of a special fiber wick structure named as "Center Fiber Wick" which can provide sufficient vapor space on the both sides of the wick structure. We also developed a cooling module that uses this kind of ultra-thin heat pipe to eliminate the hot spot issue. This cooling module consists of an ultra-thin heat pipe and a metal plate. By changing the width, the flattened thickness and the effective length of the ultra-thin heat pipe, several experiments have been conducted to characterize the thermal properties of the developed cooling module. In addition, other experiments were also conducted to determine the effects of changes in the number of heat pipes in a single module. Characterization and comparison of the module have also been conducted both experimentally and theoretically.

  12. Clinical assessment of hip strength using a hand-held dynamometer is reliable

    DEFF Research Database (Denmark)

    Thorborg, K; Petersen, J; Magnusson, S P

    2010-01-01

    rotation (ER), internal rotation (IR), flexion (FLEX) and extension (EXT) using a hand-held dynamometer. Nine subjects (five males, four females), physically active for at least 2.5 h a week, were included. Twelve standardized isometric strength tests were performed twice with a 1-week interval in between......Hip strength assessment plays an important role in the clinical examination of the hip and groin region. The primary aim of this study was to examine the absolute test-retest measurement variation concerning standardized strength assessments of hip abduction (ABD), adduction (ADD), external...... by the same examiner. The test order was randomized to avoid systematic bias. Measurement variation between sessions was 3-12%. When the maximum value of four measurements was used, test-retest measurement variation was below 10% in 11 of the 12 individual hip strength tests and below 5% in five of the 12...

  13. Diagnosis and evaluation of diseases of the hand by intravenous digital subtraction angiography done by an improved method

    International Nuclear Information System (INIS)

    Minakuchi, Kazuo; Nakamura, Kenji; Kudoh, Hiroaki; Takashima, Sumio; Manabe, Takao; Kaminoh, Toshio; Onoyama, Yasuto

    1988-01-01

    Twenty patients with various diseases of the hand were studied by intravenous digital subtraction angiography (IV-DSA). We used clay preparation as a compensatory filter to improve the radiological conditions and increased local circulation by use of a hot compress. By IV-DSA done in this way, excellent or good images of the carpal arteries were obtained in 21 of 23 hands examined (91%). For the metacarpal region, images were excellent or good for 13 hands (57%), and for the digital region, for 4 (17%). The arteries of the hand could be seen in all studies, although sometimes the image was poor. Further improvements of images by IV-DSA should make it possible to use IV-DSA for screening and follow-up studies of many parts of the body. (author)

  14. Comparison of maximal voluntary isometric contraction and hand-held dynamometry in measuring muscle strength of patients with progressive lower motor neuron syndrome

    NARCIS (Netherlands)

    Visser, J.; Mans, E.; de Visser, M.; van den Berg-Vos, R. M.; Franssen, H.; de Jong, J. M. B. V.; van den Berg, L. H.; Wokke, J. H. J.; de Haan, R. J.

    2003-01-01

    Context. Maximal voluntary isometric contraction, a method quantitatively assessing muscle strength, has proven to be reliable, accurate and sensitive in amyotrophic lateral sclerosis. Hand-held dynamometry is less expensive and more quickly applicable than maximal voluntary isometric contraction.

  15. A study of fundus status in myopia

    Directory of Open Access Journals (Sweden)

    Christina Samuel, Sundararajan D

    2014-07-01

    Full Text Available Background: The most important sensory organ for a human is the eye. Any damage to the retina can cause diminution or loss of vision. One of the most important refractive errors of the eye is Myopia apart from hypermetropia and astigmatism. It is one of the commonest conditions seen in everyday practice. Myopic degeneration is one of the common causes of decreased visual acuity. Aim: The aim of this clinical study is to observe the fundus changes associated with Myopia. Methods: A prospective study of 100 cases of myopia were included in this study. Detailed anterior segment and good posterior segment examination after achieving mydriasis was done with a direct ophthalmoscope and indirect ophthalmoscope with 20D lens. Result: In our study, we found that males were more commonly affected than females with myopia (54%. 50% of the cases affected belonged to the student community. 53.68% had positive changes in the retina suggestive of degenerative changes in the fundus. Conclusion: Degenerative changes of fundus are most commonly seen in myopic patients of which Tessellated fundus was about 90.20%. Vitreous degenerative changes for 70.59%. Crescent formation was 87.25%. Dull foveal reflex in 82.35% and lattice degeneration accounted for 40%.

  16. Potential air contamination during CO2 angiography using a hand-held syringe: theoretical considerations and gas chromatography.

    Science.gov (United States)

    Cho, David R; Cho, Kyung J; Hawkins, Irvin F

    2006-01-01

    To assess air contamination in the hand-held syringes currently used for CO2 delivery and to determine whether there is an association between their position and the rate of air contamination. Assessment of air contamination in the syringe (20 ml) included theoretical modeling, mathematical calculation, and gas chromatography (GC). The model was used with Fick's first law to calculate the diffusion of CO2 and the amount of air contamination. For GC studies, the syringes were placed in the upright, horizontal, and inverted positions and gas samples were obtained after 5, 10, 20, 30, and 60 min. All trials with each position for each sampling time were performed five times. The amounts of air contamination with time calculated mathematically were 5-10% less than those of GC. With the diffusivity of air-CO2 at 0.1599 cm2/sec (9.594 cm2/min), air contamination was calculated to be 60% at 60 min. With GC air contamination was 13% at 5 min, 31% at 20 min, 43% at 30 min, and 68% at 60 min. There was no difference in air contamination between the different syringe positions. Air contamination occurs in hand-held syringes filled with CO2 when they are open to the ambient air. The amounts of air contamination over time are similar among syringes placed in the upright, horizontal, and inverted positions.

  17. Qualitative Evaluation of Digital Hand X-rays is Not a Reliable Method to Assess Bone Mineral Density

    Directory of Open Access Journals (Sweden)

    AndrewJ. Miller

    2017-01-01

    Full Text Available Object: The gold standard for evaluating bone mineral density is dual energy x-ray absorptiometry (DEXA.  Prior studies have shown poor reliability using analog wrist X-rays in diagnosing osteoporosis. Our goal was to investigate if there was improved diagnostic value to visual assessment of digital hand X-rays in osteoporosis screening. We hypothesized that similar to analog counterparts, digital hand X-rays have poor correlation and reliability in determining bone mineral density (BMD relative to DEXA.Methods: We prospectively evaluated female patients older than 65 years who presented to our hand clinic with digital hand and wrist X-rays as part of their evaluation over six months. Patients who had a fracture and were without DEXA scans within the past two years were excluded. Five fellowship-trained hand surgeons, blinded to DEXA T-scores, evaluated the x-rays over two assessments separated by four weeks and classified them as osteoporotic, osteopenic, or normal BMD.  Accuracy relative to DEXA T-score, interobserver and intraobserver rates were calculated.Results: Thirty four patients met the inclusion criteria and a total of 340 x-rays reviews were performed.  The assessments were correct in 169 cases (49% as compared to the DEXA T-scores. A mean weighted kappa coefficient of agreement between observers was 0.29 (range 0.02-0.41 reflecting a fair agreement. The first and second assessment for all five physicians was 0.46 (range 0.19-0.78 reflecting a moderate agreement.  Grouping osteoporosis and osteopenia together compared to normal, the accuracy, interobserver and intraobserver rates increased to 63%, 0.42 and 0.54 respectively.Conclusion: Abnormally low BMD is a common occurrence in patients treated for upper extremity disorders. There is poor accuracy relative to DEXA scan and only fair agreement in diagnosing osteoporosis using visual assessments of digital x-rays.

  18. Fundus autofluorescence and colour fundus imaging compared during telemedicine screening in patients with diabetes.

    Science.gov (United States)

    Kolomeyer, Anton M; Baumrind, Benjamin R; Szirth, Bernard C; Shahid, Khadija; Khouri, Albert S

    2013-06-01

    We investigated the use of fundus autofluorescence (FAF) imaging in screening the eyes of patients with diabetes. Images were obtained from 50 patients with type 2 diabetes undergoing telemedicine screening with colour fundus imaging. The colour and FAF images were obtained with a 15.1 megapixel non-mydriatic retinal camera. Colour and FAF images were compared for pathology seen in nonproliferative and proliferative diabetic retinopathy (NPDR and PDR, respectively). A qualitative assessment was made of the ease of detecting early retinopathy changes and the extent of existing retinopathy. The mean age of the patients was 47 years, most were male (82%) and most were African American (68%). Their mean visual acuity was 20/45 and their mean intraocular pressure was 14.3 mm Hg. Thirty-eight eyes (76%) did not show any diabetic retinopathy changes on colour or FAF imaging. Seven patients (14%) met the criteria for NPDR and five (10%) for severe NPDR or PDR. The most common findings were microaneurysms, hard exudates and intra-retinal haemorrhages (IRH) (n = 6 for each). IRH, microaneurysms and chorioretinal scars were more easily visible on FAF images. Hard exudates, pre-retinal haemorrhage and fibrosis, macular oedema and Hollenhorst plaque were easier to identify on colour photographs. The value of FAF imaging as a complementary technique to colour fundus imaging in detecting diabetic retinopathy during ocular screening warrants further investigation.

  19. Three-dimensional modeling of physiological tremor for hand-held surgical robotic instruments.

    Science.gov (United States)

    Tatinati, Sivanagaraja; Yan Naing Aye; Pual, Anand; Wei Tech Ang; Veluvolu, Kalyana C

    2016-08-01

    Hand-held robotic instruments are developed to compensate physiological tremor in real-time while augmenting the required precision and dexterity into normal microsurgical work-flow. The hardware (sensors and actuators) and software (causal linear filters) employed for tremor identification and filtering introduces time-varying unknown phase-delay that adversely affects the device performance. The current techniques that focus on three-dimensions (3D) tip position control involves modeling and canceling the tremor in 3-axes (x, y, and z axes) separately. Our analysis with the tremor data recorded from surgeons and novice subjects show that there exists significant correlation in tremor motion across the dimensions. Motivated by this, a new multi-dimensional modeling approach based on extreme learning machines (ELM) is proposed in this paper to correct the phase delay and to accurately model tremulous motion in three dimensions simultaneously. A study is conducted with tremor data recorded from the microsurgeons to analyze the suitability of proposed approach.

  20. The role of hand drawing in basic design education in the digital age

    NARCIS (Netherlands)

    Have, R.; Van den Toorn, M.W.M.

    2012-01-01

    In the last decennia, hand drawing has been slowly moved out of the curricula in architecture schools and the teaching of computer skills has taken over. It has also created an 'intellectual dichotomy of viewpoints'; the digital and analogues. The question now is how to find a new balance for

  1. Hand-held hyperspectral imager for chemical/biological and environmental applications

    Science.gov (United States)

    Hinnrichs, Michele; Piatek, Bob

    2004-03-01

    A small, hand held, battery operated imaging infrared spectrometer, Sherlock, has been developed by Pacific Advanced Technology and was field tested in early 2003. The Sherlock spectral imaging camera has been designed for remote gas leak detection, however, the architecture of the camera is versatile enough that it can be applied to numerous other applications such as homeland security, chemical/biological agent detection, medical and pharmaceutical applications as well as standard research and development. This paper describes the Sherlock camera, theory of operations, shows current applications and touches on potential future applications for the camera. The Sherlock has an embedded Power PC and performs real-time-image processing function in an embedded FPGA. The camera has a built in LCD display as well as output to a standard monitor, or NTSC display. It has several I/O ports, ethernet, firewire, RS232 and thus can be easily controlled from a remote location. In addition, software upgrades can be performed over the ethernet eliminating the need to send the camera back to the factory for a retrofit. Using the USB port a mouse and key board can be connected and the camera can be used in a laboratory environment as a stand alone imaging spectrometer.

  2. Do it yourself smartphone fundus camera – DIYretCAM

    Directory of Open Access Journals (Sweden)

    Biju Raju

    2016-01-01

    Full Text Available This article describes the method to make a do it yourself smartphone-based fundus camera which can image the central retina as well as the peripheral retina up to the pars plana. It is a cost-effective alternative to the fundus camera.

  3. Realization of the ergonomics design and automatic control of the fundus cameras

    Science.gov (United States)

    Zeng, Chi-liang; Xiao, Ze-xin; Deng, Shi-chao; Yu, Xin-ye

    2012-12-01

    The principles of ergonomics design in fundus cameras should be extending the agreeableness by automatic control. Firstly, a 3D positional numerical control system is designed for positioning the eye pupils of the patients who are doing fundus examinations. This system consists of a electronically controlled chin bracket for moving up and down, a lateral movement of binocular with the detector and the automatic refocusing of the edges of the eye pupils. Secondly, an auto-focusing device for the object plane of patient's fundus is designed, which collects the patient's fundus images automatically whether their eyes is ametropic or not. Finally, a moving visual target is developed for expanding the fields of the fundus images.

  4. Detection of Fundus Lesions Using Classifier Selection

    Science.gov (United States)

    Nagayoshi, Hiroto; Hiramatsu, Yoshitaka; Sako, Hiroshi; Himaga, Mitsutoshi; Kato, Satoshi

    A system for detecting fundus lesions caused by diabetic retinopathy from fundus images is being developed. The system can screen the images in advance in order to reduce the inspection workload on doctors. One of the difficulties that must be addressed in completing this system is how to remove false positives (which tend to arise near blood vessels) without decreasing the detection rate of lesions in other areas. To overcome this difficulty, we developed classifier selection according to the position of a candidate lesion, and we introduced new features that can distinguish true lesions from false positives. A system incorporating classifier selection and these new features was tested in experiments using 55 fundus images with some lesions and 223 images without lesions. The results of the experiments confirm the effectiveness of the proposed system, namely, degrees of sensitivity and specificity of 98% and 81%, respectively.

  5. Effect of isoproterenol, phenylephrine, and sodium nitroprusside on fundus pulsations in healthy volunteers.

    Science.gov (United States)

    Schmetterer, L; Wolzt, M; Salomon, A; Rheinberger, A; Unfried, C; Zanaschka, G; Fercher, A F

    1996-03-01

    Recently a laser interferometric method for topical measurement of fundus pulsations has been developed. Fundus pulsations in the macular region are caused by the inflow and outflow of blood into the choroid. The purpose of this work was to study the influence of a peripheral vasoconstricting (the alpha 1 adrenoceptor agonist phenylephrine), a predominantly positive inotropic (the non-specific beta adrenoceptor agonist isoproterenol), and a non-specific vasodilating (sodium nitroprusside) model drug on ocular fundus pulsations to determine reproducibility and sensitivity of the method. In a double masked randomised crossover study the drugs were administered in stepwise increasing doses to 10 male and nine female healthy volunteers. Systemic haemodynamic variables and fundus pulsations were measured at all infusion steps. Fundus pulsation increased during infusion of isoproterenol with statistical significance versus baseline at the lowest dose of 0.1 microgram/min. Neither peripheral vasoconstriction nor peripheral vasodilatation affected the ocular fundus pulsations. Measurements of fundus pulsations is a highly reproducible method in healthy subjects with low ametropy. Changes of local pulsatile ocular blood flow were detectable with our method following the infusion of isoproterenol. As systemic pharmacological vasodilatation or vasoconstriction did not change fundus pulsations, further experimental work has to be done to evaluate the sensitivity of the laser interferometric fundus pulsation measurement in various eye diseases.

  6. Your fate is in your hands? Handedness, digit ratio (2D:4D), and selection to a national talent development system.

    Science.gov (United States)

    Baker, Joseph; Kungl, Ann-Marie; Pabst, Jan; Strauß, Bernd; Büsch, Dirk; Schorer, Jörg

    2013-01-01

    Over the past decade a small evidence base has highlighted the potential importance of seemingly innocuous variables related to one's hands, such as hand dominance and the relative length of the second and fourth digits (2D:4D ratio), to success in sport. This study compared 2D:4D digit ratio and handedness among handball players selected to advance in a national talent development system with those not selected. Participants included 480 youth handball players (240 females and 240 males) being considered as part of the talent selection programme for the German Youth National team. Hand dominance and digit ratio were compared to age-matched control data using standard t-tests. There was a greater proportion of left-handers compared to the normal population in males but not in females. There was also a lower digit ratio in both females and males. However, there were no differences between those selected for the next stage of talent development and those not selected on either handedness or digit ratio. These results add support for general effects for both digit ratio and handedness in elite handball; however, these factors seem inadequate to explain talent selection decisions at this level.

  7. Potential Air Contamination During CO2 Angiography Using a Hand-Held Syringe: Theoretical Considerations and Gas Chromatography

    International Nuclear Information System (INIS)

    Cho, David R.; Cho, Kyung J.; Hawkins, Irvin F.

    2006-01-01

    Purpose. To assess air contamination in the hand-held syringes currently used for CO 2 delivery and to determine whether there is an association between their position and the rate of air contamination. Methods. Assessment of air contamination in the syringe (20 ml) included theoretical modeling, mathematical calculation, and gas chromatography (GC). The model was used with Fick's first law to calculate the diffusion of CO 2 and the amount of air contamination. For GC studies, the syringes were placed in the upright, horizontal, and inverted positions and gas samples were obtained after 5, 10, 20, 30, and 60 min. All trials with each position for each sampling time were performed five times. Results. The amounts of air contamination with time calculated mathematically were 5-10% less than those of GC. With the diffusivity of air-CO 2 at 0.1599 cm 2 /sec (9.594 cm 2 /min), air contamination was calculated to be 60% at 60 min. With GC air contamination was 13% at 5 min, 31% at 20 min, 43% at 30 min, and 68% at 60 min. There was no difference in air contamination between the different syringe positions. Conclusion. Air contamination occurs in hand-held syringes filled with CO 2 when they are open to the ambient air. The amounts of air contamination over time are similar among syringes placed in the upright, horizontal, and inverted positions

  8. Development and performance of a hand-held CZT detector for in-situ measurements at the emergency response

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Young Yong; Chung, Kun Ho; Kim, Chang Jong; Lee, Wan No; Choi, Geun Sik; Kang, Mun Ja [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Yoon, Jin [SI Detection Co. Ltd, Daejeon (Korea, Republic of)

    2016-06-15

    A hand-held detector for an emergency response was developed for nuclide identification and to estimate the information of the ambient dose rate in the scene of an accident as well as the radioactivity of the contaminants. To achieve this, the most suitable sensor was first selected as a cadmium zinc telluride (CZT) semiconductor and the signal processing unit from a sensor and the signal discrimination and storage unit were successfully manufactured on a printed circuit board. The performance of the developed signal processing unit was then evaluated to have an energy resolution of about 14 keV at 662 keV. The system control unit was also designed to operate the CZT detector, monitor the detector, battery, and interface status, and check and transmit the measured results of the ambient dose rate and radioactivity. In addition, a collimator, which can control the inner radius, and the airborne dust sampler, which consists of an air filter and charcoal filter, were developed and mounted to the developed CZT detector for the quick and efficient response of a nuclear accident. The hand-held CZT detector was developed to make the in-situ gamma-ray spectrometry and its performance was checked to have a good energy resolution. In addition, the collimator and the airborne dust sampler were developed and mounted to the developed CZT detector for a quick and efficient response to a nuclear accident.

  9. Digital Waveguide Architectures for Virtual Musical Instruments

    Science.gov (United States)

    Smith, Julius O.

    Digital sound synthesis has become a standard staple of modern music studios, videogames, personal computers, and hand-held devices. As processing power has increased over the years, sound synthesis implementations have evolved from dedicated chip sets, to single-chip solutions, and ultimately to software implementations within processors used primarily for other tasks (such as for graphics or general purpose computing). With the cost of implementation dropping closer and closer to zero, there is increasing room for higher quality algorithms.

  10. Nonmydriatic Ocular Fundus Photography in the Emergency Department: How It Can Benefit Neurologists.

    Science.gov (United States)

    Bruce, Beau B

    2015-10-01

    Examination of the ocular fundus is a critical aspect of the neurologic examination. For example, in patients with headache the ocular fundus examination is needed to uncover "red flags" suggestive of secondary etiologies. However, ocular fundus examination is infrequently and poorly performed in clinical practice. Nonmydriatic ocular fundus photography provides an alternative to direct ophthalmoscopy that has been studied as part of the Fundus Photography versus Ophthalmoscopy Trial Outcomes in the Emergency Department (FOTO-ED) Study. Herein, the results of the FOTO-ED study are reviewed with a particular focus on the study's implications for the acute care of patients presenting with headache and focal neurologic deficits. In headache patients, not only optic disc edema and optic disc pallor were observed as would be expected, but also a large number of abnormalities associated with hypertension. Based upon subjects with focal neurologic deficits, the FOTO-ED study suggests that the ocular fundus examination may assist with the triage of patients presenting with suspected transient ischemic attack. Continued advances in the ease and portability of nonmydriatic fundus photography will hopefully help to restore ocular fundus examination as a routinely performed component of all neurologic examinations. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  11. Prevention of increased abnormal fundus autofluorescence with blue light-filtering intraocular lenses.

    Science.gov (United States)

    Nagai, Hiroyuki; Hirano, Yoshio; Yasukawa, Tsutomu; Morita, Hiroshi; Nozaki, Miho; Wolf-Schnurrbusch, Ute; Wolf, Sebastian; Ogura, Yuichiro

    2015-09-01

    To observe changes in fundus autofluorescence 2 years after implantation of blue light-filtering (yellow-tinted) and ultraviolet light-filtering (colorless) intraocular lenses (IOLs). Department of Ophthalmology and Visual Science, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan, and the Department of Ophthalmology, University of Bern, Bern, Switzerland. Prospective comparative observational study. Patients were enrolled who had cataract surgery with implantation of a yellow-tinted or colorless IOL and for whom images were obtained on which the fundus autofluorescence was measurable using the Heidelberg Retina Angiogram 2 postoperatively. The fundus autofluorescence in the images was classified into 8 abnormal patterns based on the classification of the International Fundus Autofluorescence Classification Group, The presence of normal fundus autofluorescence, geographic atrophy, and wet age-related macular degeneration (AMD) also was recorded. The fundus findings at baseline and 2 years postoperatively were compared. Fifty-two eyes with a yellow-tinted IOL and 79 eyes with a colorless IOL were included. Abnormal fundus autofluorescence did not develop or increase in the yellow-tinted IOL group; however, progressive abnormal fundus autofluorescence developed or increased in 12 eyes (15.2%) in the colorless IOL group (P = .0016). New drusen, geographic atrophy, and choroidal neovascularization were observed mainly in the colorless IOL group. The incidence of AMD was statistically significantly higher in the colorless IOL group (P = .042). Two years after cataract surgery, significant differences were seen in the progression of abnormal fundus autofluorescence between the 2 groups. The incidence of AMD was lower in eyes with a yellow-tinted IOL. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Characterization of wood dust emission from hand-held woodworking machines.

    Science.gov (United States)

    Keller, F-X; Chata, F

    2018-01-01

    This article focuses on the prevention of exposure to wood dust when operating electrical hand-held sawing and sanding machines. A laboratory methodology was developed to measure the dust concentration around machines during operating processes. The main objective was to characterize circular saws and sanders, with the aim of classifying the different power tools tested in terms of dust emission (high dust emitter vs. low dust emitter). A test set-up was developed and is described and a measurement methodology was determined for each of the two operations studied. The robustness of the experimental results is discussed and shows good tendencies. The impact of air-flow extraction rate was assessed and the pressure loss of the system for each machine established. For the circular saws, three machines over the nine tested could be classified in the low dust emitter group. Their mean concentration values measured are between 0.64 and 0.98 mg/m 3 for the low dust emitter group and from 2.55 and 4.37 mg/m 3 for the high dust emitter group. From concentration measurements, a machine classification is possible-one for sanding machines and one for sawing machines-and a ratio from 1-7 is obtained when comparing the results. This classification will be helpful when a choice of high performance power tools, in terms of dust emission, must be made by professionals.

  13. Long-term fundus changes in acquired partial lipodystrophy.

    Science.gov (United States)

    Jansen, Joyce; Delaere, Lien; Spielberg, Leigh; Leys, Anita

    2013-11-18

    We describe long-term fundus changes in a patient with partial lipodystrophy (PL). Retinal pigment alterations, drusen and subretinal neovascularisation were seen without evidence for membranoproliferative glomerulonephritis. Fundus alterations similar to those seen in age-related macular degeneration can occur at an earlier age in patients with PL, even without renal disease. Dysregulation of an alternative complement pathway with low serum levels of C3 has been implicated as a pathogenetic mechanism.

  14. Investigating the Learning Challenges Presented by Digital Technologies to the College of Education in Kuwait University

    Science.gov (United States)

    Aldhafeeri, Fayiz; Male, Trevor

    2016-01-01

    There is now widespread recognition that digital technologies, particularly portable hand held devices capable of Internet connection, present opportunities and challenges to the way in which student learning is organized in schools, colleges and institutions of higher education in the 21st Century. Traxler, "Journal of the Research Centre…

  15. Fundus autofluorescence in retinal artery occlusion: A more precise diagnosis.

    Science.gov (United States)

    Bacquet, J-L; Sarov-Rivière, M; Denier, C; Querques, G; Riou, B; Bonin, L; Barreau, E; Labetoulle, M; Rousseau, A

    2017-10-01

    Retinal artery occlusion (RAO) is a medical emergency associated with a high risk of cerebral vascular accident and other cardiovascular events. Among patients with non-arteritic RAO, a retinal embolus is observed in approximately 40% of cases. Fundus examination and retinography are not reliable to predict the nature of the emboli. We report three consecutive cases of central and branch RAO that were investigated with fundus autofluorescence, fluorescein angiography and color retinal photographs. All patients underwent complete neurological and cardiovascular workups, with brain imaging, cardiac Doppler ultrasound, carotid Dopplers and Holter ECG's, to determine the underlying mechanism of retinal embolism. In the three cases, aged 77.7±4 years (2 women and 1 man), fundus autofluorescence demonstrated hyperautofluorescent emboli. In two cases, it allowed visualization of emboli that were not detected with fundus examination or retinography. The cardiovascular work-up demonstrated atheromatous carotid or aortic plaques in all patients. In one case, it permitted the diagnosis of RAO. Two of the three cases were considered to be of atherosclerotic origin and one of undefined origin. Fundus autofluorescence may help to detect and characterize retinal emboli. Since lipofuscin, which is present in large quantity in atherosclerotic plaques, is the main fluorophore detected with fundus autofluorescence, this non-invasive and simple examination may give information about the underlying mechanism of retinal embolism, and thus impact the etiologic assessment of RAO. Additional studies are necessary to confirm this potential role of autofluorescence. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  16. Personal identification based on blood vessels of retinal fundus images

    Science.gov (United States)

    Fukuta, Keisuke; Nakagawa, Toshiaki; Hayashi, Yoshinori; Hatanaka, Yuji; Hara, Takeshi; Fujita, Hiroshi

    2008-03-01

    Biometric technique has been implemented instead of conventional identification methods such as password in computer, automatic teller machine (ATM), and entrance and exit management system. We propose a personal identification (PI) system using color retinal fundus images which are unique to each individual. The proposed procedure for identification is based on comparison of an input fundus image with reference fundus images in the database. In the first step, registration between the input image and the reference image is performed. The step includes translational and rotational movement. The PI is based on the measure of similarity between blood vessel images generated from the input and reference images. The similarity measure is defined as the cross-correlation coefficient calculated from the pixel values. When the similarity is greater than a predetermined threshold, the input image is identified. This means both the input and the reference images are associated to the same person. Four hundred sixty-two fundus images including forty-one same-person's image pairs were used for the estimation of the proposed technique. The false rejection rate and the false acceptance rate were 9.9×10 -5% and 4.3×10 -5%, respectively. The results indicate that the proposed method has a higher performance than other biometrics except for DNA. To be used for practical application in the public, the device which can take retinal fundus images easily is needed. The proposed method is applied to not only the PI but also the system which warns about misfiling of fundus images in medical facilities.

  17. Non-mydriatic ocular fundus photography in the emergency department: how it can benefit neurologists

    Science.gov (United States)

    Bruce, Beau B.

    2016-01-01

    Examination of the ocular fundus is a critical aspect of the neurological examination. For example, in patients with headache the ocular fundus examination is needed to uncover “red flags” suggestive of secondary etiologies. However, ocular fundus examination is infrequently and poorly performed in clinical practice. Non-mydriatic ocular fundus photography provides an alternative to direct ophthalmoscopy that has been studied as part of the Fundus photography vs. Ophthalmoscopy Trial Outcomes in the Emergency Department (FOTO-ED) study. Herein, we review the results of the FOTO-ED study with a particular focus on the study's implications for the acute care of patients presenting with headache and focal neurologic deficits. In headache patients, we not only observed optic disc edema and optic disc pallor as would be expected, but also a large number of abnormalities associated with hypertension. Based upon subjects with focal neurological deficits, the FOTO-ED study suggests that the ocular fundus examination may assist with the triage of patients presenting with suspected transient ischemic attack. Continued advances in the ease and portability of non-mydriatic fundus photography will hopefully help to restore ocular fundus examination as a routinely performed component of all neurological examinations. PMID:26444394

  18. Digital fringe projection for hand surface coordinate variation analysis caused by osteoarthritis

    Science.gov (United States)

    Nor Haimi, Wan Mokhdzani Wan; Hau Tan, Cheek; Retnasamy, Vithyacharan; Vairavan, Rajendaran; Sauli, Zaliman; Roshidah Yusof, Nor; Hambali, Nor Azura Malini Ahmad; Aziz, Muhammad Hafiz Ab; Bakhit, Ahmad Syahir Ahmad

    2017-11-01

    Hand osteoarthritis is one of the most common forms of arthritis which impact millions of people worldwide. The disabling problem occurs when the protective cartilage on the boundaries of bones wear off over time. Currently, in order to identify hand osteoarthritis, special instruments namely X-ray scanning and MRI are used for the detection but it also has its limitations such as radiation exposure and can be quite costly. In this work, an optical metrology system based on digital fringe projection which comprises of an LCD projector, CCD camera and a personal computer has been developed to anticipate abnormal growth or deformation on the joints of the hand which are common symptoms of osteoarthritis. The main concept of this optical metrology system is to apply structured light as imaging source for surface change detection. The imaging source utilizes fringe patterns generated by C++ programming and is shifted by 3 phase shifts based on the 3 steps 2 shifts method. Phase wrapping technique and analysis were applied in order to detect the deformation of live subjects. The result has demonstrated a successful method of hand deformation detection based on the pixel tracking differences of a normal and deformed state.

  19. Fundus autofluorescence: applications and perspectives.

    Science.gov (United States)

    Cuba, J; Gómez-Ulla, F

    2013-02-01

    To describe the findings of the study of autofluorescence of the different retinal diseases included in the study. To determine in which diseases autofluorescence may be more, or just as, useful as fluorescein angiography (FAG) in terms of diagnostic information. We studied the retinal autofluorescence of 123 eyes of 93 patients, including various diseases of the eye fundus. In all cases we explored the fundus, retinal autofluorescence, and, if indicated, FAG was performed. Analysis of the autofluorescence was performed using the Heidelberg Retina angiography Angiograph 2 (HRA2) Heidelberg Engineering (Germany). The autofluorescence information provided was equal or better (than FAG) in: 68.18% of cases of macular edema, 50% of pigment epithelium detachments, 100% of pigment epithelium atrophies, 100% of central serous chorioretinopathy; 55.55% of choroidal neovascularization, 100% of retinal dystrophies with deposition of lipofuscin, 100% of hard exudates and pre-retinal hemorrhages. Autofluorescence is a quick and non-invasive examination method, comfortable for both patient and examiner, and with a very short learning curve. It provides diagnostic information about many eye fundus diseases. While more studies and more experience with its use are needed, its interest lies in the possibility of avoiding the performing of angiography in patients with these diseases, and in the additional information autofluorescence provides about the functional situation of cells and retinal pigments. Copyright © 2011 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  20. Hyperspectral fundus imager

    Science.gov (United States)

    Truitt, Paul W.; Soliz, Peter; Meigs, Andrew D.; Otten, Leonard John, III

    2000-11-01

    A Fourier Transform hyperspectral imager was integrated onto a standard clinical fundus camera, a Zeiss FF3, for the purposes of spectrally characterizing normal anatomical and pathological features in the human ocular fundus. To develop this instrument an existing FDA approved retinal camera was selected to avoid the difficulties of obtaining new FDA approval. Because of this, several unusual design constraints were imposed on the optical configuration. Techniques to calibrate the sensor and to define where the hyperspectral pushbroom stripe was located on the retina were developed, including the manufacturing of an artificial eye with calibration features suitable for a spectral imager. In this implementation the Fourier transform hyperspectral imager can collect over a hundred 86 cm-1 spectrally resolved bands with 12 micro meter/pixel spatial resolution within the 1050 nm to 450 nm band. This equates to 2 nm to 8 nm spectral resolution depending on the wavelength. For retinal observations the band of interest tends to lie between 475 nm and 790 nm. The instrument has been in use over the last year successfully collecting hyperspectral images of the optic disc, retinal vessels, choroidal vessels, retinal backgrounds, and macula diabetic macular edema, and lesions of age-related macular degeneration.

  1. Hand-held dynamic visual noise reduces naturally occurring food cravings and craving-related consumption.

    Science.gov (United States)

    Kemps, Eva; Tiggemann, Marika

    2013-09-01

    This study demonstrated the applicability of the well-established laboratory task, dynamic visual noise, as a technique for reducing naturally occurring food cravings and subsequent food intake. Dynamic visual noise was delivered on a hand-held computer device. Its effects were assessed within the context of a diary study. Over a 4-week period, 48 undergraduate women recorded their food cravings and consumption. Following a 2-week baseline, half the participants watched the dynamic visual noise display whenever they experienced a food craving. Compared to a control group, these participants reported less intense cravings. They were also less likely to eat following a craving and consequently consumed fewer total calories following craving. These findings hold promise for curbing unwanted food cravings and craving-driven consumption in real-world settings. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. A hand-held 3D laser scanning with global positioning system of subvoxel precision

    International Nuclear Information System (INIS)

    Arias, Nestor; Meneses, Nestor; Meneses, Jaime; Gharbi, Tijani

    2011-01-01

    In this paper we propose a hand-held 3D laser scanner composed of an optical head device to extract 3D local surface information and a stereo vision system with subvoxel precision to measure the position and orientation of the 3D optical head. The optical head is manually scanned over the surface object by the operator. The orientation and position of the 3D optical head is determined by a phase-sensitive method using a 2D regular intensity pattern. This phase reference pattern is rigidly fixed to the optical head and allows their 3D location with subvoxel precision in the observation field of the stereo vision system. The 3D resolution achieved by the stereo vision system is about 33 microns at 1.8 m with an observation field of 60cm x 60cm.

  3. The Complimentary Role of Methoxy-Isobutyl-Isonitrile and Hand-Held Gamma Probe in Adamantinoma

    Science.gov (United States)

    Maharaj, Masha; Korowlay, Nisaar; Ellmann, Prof

    2016-01-01

    Adamantinoma is a rare locally aggressive osteolytic tumor that is found 90% of the time in the diaphysis of the tibia with the remaining lesions found in the fibula and long tubular bones. A case of adamantinoma of the tibia is presented. The added value of nuclear medicine investigations in the workup of this patient is described. A three-phase whole body 99mTc-methylene diphosphonate bone and a whole body 99mTc-methoxy-isobutyl-isonitrile scans were complimentary in the demarcation of viable bone tumor and the assessment of the remainder of the bone and soft tissue to exclude other sites. Intra-operative assistance with a hand-held gamma probe, guided the biopsy of the most metabolically active tumor tissue. Histology revealed a biphasic tumor composed of epithelial and fibrous components, in keeping with an adamantinoma. PMID:26912979

  4. Advanced digital counting rate meter for gamma ray logging

    International Nuclear Information System (INIS)

    Kannan, S.; Meenakshi Sundari, A.; Rai, A.K.

    2013-01-01

    A compact, hand held controller based Advanced Digital Count Rate Meter (ADCRM) as a replacement of bulky Count Rate (analog) Meters (SBL-2A) was designed, developed and fabricated to carry out Gamma-Ray borehole logging with Geiger Muller (GM) tubes and Scintillation (SC) detectors. In the hardware the functionality of analog meter simulation, digital counting of gamma events and auto reference adjustment to use different length of armour cable winches were implemented. The in-built software evaluates grade in ppm and at the end of logging, the reports are prepared automatically. ADCRM was developed in-house to assist the uranium mineral exploration in AMD. (author)

  5. The Role of Fundus Autofluorescence in Late-Onset Retinitis Pigmentosa (LORP) Diagnosis

    Science.gov (United States)

    Lee, Tamara J.; Hwang, John C.; Chen, Royce W. S.; Lima, Luiz H.; Wang, Nan-Kai; Tosi, Joaquin; Freund, K. Bailey; Yannuzzi, Lawrence A.; Tsang, Stephen H.

    2015-01-01

    Purpose To demonstrate the utility and characteristics of fundus autofluorescence in late-onset retinitis pigmentosa. Methods Observational case series. Patients diagnosed with late-onset retinitis pigmentosa were identified retrospectively in an institutional setting. Twelve eyes of six patients were identified and medical records were reviewed. Results All patients presented with slowly progressive peripheral field loss and initial clinical examination revealed only subtle retinal changes. There was a notable lack of intraretinal pigment migration in all patients. Five out of six patients underwent magnetic resonance imaging of the brain to rule out intracranial processes and all were referred from another ophthalmologist for further evaluation. Fundus autofluorescence was ultimately employed in all patients and revealed more extensive retinal pathology than initially appreciated on clinical examination. Fundus autofluorescence directed the workup toward a retinal etiology in all cases and led to the eventual diagnosis of late-onset retinitis pigmentosa through electroretinogram testing. Conclusion Fundus autofluorescence may be a more sensitive marker for retinal pathology than stereo fundus biomicroscopy alone in late-onset retinitis pigmentosa. Early use of fundus autofluorescence imaging in the evaluation of patients with subtle retinal lesions and complaints of peripheral field loss may be an effective strategy for timely and cost-efficient diagnosis. PMID:23899229

  6. Hand-held Raman sensor head for in-situ characterization of meat quality applying a microsystem 671 nm diode laser

    Science.gov (United States)

    Schmidt, Heinar; Sowoidnich, Kay; Maiwald, Martin; Sumpf, Bernd; Kronfeldt, Heinz-Detlef

    2009-05-01

    A hand-held Raman sensor head was developed for the in-situ characterization of meat quality. As light source, a microsystem based external cavity diode laser module (ECDL) emitting at 671 nm was integrated in the sensor head and attached to a miniaturized optical bench which contains lens optics for excitation and signal collection as well as a Raman filter stage for Rayleigh rejection. The signal is transported with an optical fiber to the detection unit which was in the initial phase a laboratory spectrometer with CCD detector. All elements of the ECDL are aligned on a micro optical bench with 13 x 4 mm2 footprint. The wavelength stability is provided by a reflection Bragg grating and the laser has an optical power of up to 200 mW. However, for the Raman measurements of meat only 35 mW are needed to obtain Raman spectra within 1 - 5 seconds. Short measuring times are essential for the hand-held device. The laser and the sensor head are characterized in terms of stability and performance for in-situ Raman investigations. The function is demonstrated in a series of measurements with raw and packaged pork meat as samples. The suitability of the Raman sensor head for the quality control of meat and other products will be discussed.

  7. Robotic Hand

    Science.gov (United States)

    1993-01-01

    The Omni-Hand was developed by Ross-Hime Designs, Inc. for Marshall Space Flight Center (MSFC) under a Small Business Innovation Research (SBIR) contract. The multiple digit hand has an opposable thumb and a flexible wrist. Electric muscles called Minnacs power wrist joints and the interchangeable digits. Two hands have been delivered to NASA for evaluation for potential use on space missions and the unit is commercially available for applications like hazardous materials handling and manufacturing automation. Previous SBIR contracts resulted in the Omni-Wrist and Omni-Wrist II robotic systems, which are commercially available for spray painting, sealing, ultrasonic testing, as well as other uses.

  8. Inter-Tester Reliability and Precision of Manual Muscle Testing and Hand-Held Dynamometry in Lower Limb Muscles of Children with Spina Bifida

    Science.gov (United States)

    Mahony, Kate; Hunt, Adrienne; Daley, Deborah; Sims, Susan; Adams, Roger

    2009-01-01

    Reliability and measurement precision of manual muscle testing (MMT) and hand-held dynamometry (HHD) were compared for children with spina bifida. Strength measures were obtained of the hip flexors, hip abductors, and knee extensors of 20 children (10 males, 10 females; mean age 9 years 10 months; range: 5 to 15 years) by two experienced physical…

  9. Hand and foot pressures in the aye-aye (Daubentonia madagascariensis) reveal novel biomechanical trade-offs required for walking on gracile digits.

    Science.gov (United States)

    Kivell, Tracy L; Schmitt, Daniel; Wunderlich, Roshna E

    2010-05-01

    Arboreal animals with prehensile hands must balance the complex demands of bone strength, grasping and manipulation. An informative example of this problem is that of the aye-aye (Daubentonia madagascariensis), a rare lemuriform primate that is unusual in having exceptionally long, gracile fingers specialized for foraging. In addition, they are among the largest primates to engage in head-first descent on arboreal supports, a posture that should increase loads on their gracile digits. We test the hypothesis that aye-ayes will reduce pressure on their digits during locomotion by curling their fingers off the substrate. This hypothesis was tested using simultaneous videographic and pressure analysis of the hand, foot and digits for five adult aye-ayes during horizontal locomotion and during ascent and descent on a 30 degrees instrumented runway. Aye-ayes consistently curled their fingers during locomotion on all slopes. When the digits were in contact with the substrate, pressures were negligible and significantly less than those experienced by the palm or pedal digits. In addition, aye-ayes lifted their hands vertically off the substrate instead of 'toeing-off' and descended head-first at significantly slower speeds than on other slopes. Pressure on the hand increased during head-first descent relative to horizontal locomotion but not as much as the pressure increased on the foot during ascent. This distribution of pressure suggests that aye-ayes shift their weight posteriorly during head-first descent to reduce loads on their gracile fingers. This research demonstrates several novel biomechanical trade-offs to deal with complex functional demands on the mammalian skeleton.

  10. Adaptive optics scanning laser ophthalmoscopy in fundus imaging, a review and update

    Directory of Open Access Journals (Sweden)

    Bing Zhang

    2017-11-01

    Full Text Available Adaptive optics scanning laser ophthalmoscopy (AO-SLO has been a promising technique in funds imaging with growing popularity. This review firstly gives a brief history of adaptive optics (AO and AO-SLO. Then it compares AO-SLO with conventional imaging methods (fundus fluorescein angiography, fundus autofluorescence, indocyanine green angiography and optical coherence tomography and other AO techniques (adaptive optics flood-illumination ophthalmoscopy and adaptive optics optical coherence tomography. Furthermore, an update of current research situation in AO-SLO is made based on different fundus structures as photoreceptors (cones and rods, fundus vessels, retinal pigment epithelium layer, retinal nerve fiber layer, ganglion cell layer and lamina cribrosa. Finally, this review indicates possible research directions of AO-SLO in future.

  11. Coordination of intrinsic and extrinsic hand muscle activity as a function of wrist joint angle during two-digit grasping.

    Science.gov (United States)

    Johnston, Jamie A; Bobich, Lisa R; Santello, Marco

    2010-04-26

    Fingertip forces result from the activation of muscles that cross the wrist and muscles whose origins and insertions reside within the hand (extrinsic and intrinsic hand muscles, respectively). Thus, tasks that involve changes in wrist angle affect the moment arm and length, hence the force-producing capabilities, of extrinsic muscles only. If a grasping task requires the exertion of constant fingertip forces, the Central Nervous System (CNS) may respond to changes in wrist angle by modulating the neural drive to extrinsic or intrinsic muscles only or by co-activating both sets of muscles. To distinguish between these scenarios, we recorded electromyographic (EMG) activity of intrinsic and extrinsic muscles of the thumb and index finger as a function of wrist angle during a two-digit object hold task. We hypothesized that changes in wrist angle would elicit EMG amplitude modulation of the extrinsic and intrinsic hand muscles. In one experimental condition we asked subjects to exert the same digit forces at each wrist angle, whereas in a second condition subjects could choose digit forces for holding the object. EMG activity was significantly modulated in both extrinsic and intrinsic muscles as a function of wrist angle (both pextrinsic and intrinsic muscles as a muscle synergy. These findings are discussed within the theoretical frameworks of synergies and common neural input across motor nuclei of hand muscles. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  12. The Avocado Hand

    LENUS (Irish Health Repository)

    Rahmani, G

    2017-11-01

    Accidental self-inflicted knife injuries to digits are a common cause of tendon and nerve injury requiring hand surgery. There has been an apparent increase in avocado related hand injuries. Classically, the patients hold the avocado in their non-dominant hand while using a knife to cut\\/peel the fruit with their dominant hand. The mechanism of injury is usually a stabbing injury to the non-dominant hand as the knife slips past the stone, through the soft avocado fruit. Despite their apparent increased incidence, we could not find any cases in the literature which describe the “avocado hand”. We present a case of a 32-year-old woman who sustained a significant hand injury while preparing an avocado. She required exploration and repair of a digital nerve under regional anaesthesia and has since made a full recovery.

  13. Hypertensive retinopathy identification through retinal fundus image using backpropagation neural network

    Science.gov (United States)

    Syahputra, M. F.; Amalia, C.; Rahmat, R. F.; Abdullah, D.; Napitupulu, D.; Setiawan, M. I.; Albra, W.; Nurdin; Andayani, U.

    2018-03-01

    Hypertension or high blood pressure can cause damage of blood vessels in the retina of eye called hypertensive retinopathy (HR). In the event Hypertension, it will cause swelling blood vessels and a decrese in retina performance. To detect HR in patients body, it is usually performed through physical examination of opthalmoscope which is still conducted manually by an ophthalmologist. Certainly, in such a manual manner, takes a ong time for a doctor to detetct HR on aa patient based on retina fundus iamge. To overcome ths problem, a method is needed to identify the image of retinal fundus automatically. In this research, backpropagation neural network was used as a method for retinal fundus identification. The steps performed prior to identification were pre-processing (green channel, contrast limited adapative histogram qualization (CLAHE), morphological close, background exclusion, thresholding and connected component analysis), feature extraction using zoning. The results show that the proposed method is able to identify retinal fundus with an accuracy of 95% with maximum epoch of 1500.

  14. Bone age assessment in Hispanic children: digital hand atlas compared with the Greulich and Pyle (G&P) atlas

    Science.gov (United States)

    Fernandez, James Reza; Zhang, Aifeng; Vachon, Linda; Tsao, Sinchai

    2008-03-01

    Bone age assessment is most commonly performed with the use of the Greulich and Pyle (G&P) book atlas, which was developed in the 1950s. The population of theUnited States is not as homogenous as the Caucasian population in the Greulich and Pyle in the 1950s, especially in the Los Angeles, California area. A digital hand atlas (DHA) based on 1,390 hand images of children of different racial backgrounds (Caucasian, African American, Hispanic, and Asian) aged 0-18 years was collected from Children's Hospital Los Angeles. Statistical analysis discovered significant discrepancies exist between Hispanic and the G&P atlas standard. To validate the usage of DHA as a clinical standard, diagnostic radiologists performed reads on Hispanic pediatric hand and wrist computed radiography images using either the G&P pediatric radiographic atlas or the Children's Hospital Los Angeles Digital Hand Atlas (DHA) as reference. The order in which the atlas is used (G&P followed by DHA or vice versa) for each image was prepared before actual reading begins. Statistical analysis of the results was then performed to determine if a discrepancy exists between the two readings.

  15. Design, data, and theory regarding a digital hand inclinometer: a portable device for studying slant perception.

    Science.gov (United States)

    Li, Zhi; Durgin, Frank H

    2011-06-01

    Palm boards are often used as a nonverbal measure in human slant perception studies. It was recently found that palm boards are biased and relatively insensitive measures, and that an unrestricted hand gesture provides a more sensitive response (Durgin, Hajnal, Li, Tonge, & Stigliani, Acta Psychologica, 134, 182-197, 2010a). In this article, we describe an original design for a portable lightweight digital device for measuring hand orientation. This device is microcontroller-based and uses a micro inclinometer chip as its inclination sensor. The parts are fairly inexpensive. This device, used to measure hand orientation, provides a sensitive nonverbal method for studying slant perception, which can be used in both indoor and outdoor environments. We present data comparing the use of a free hand to palm-board and verbal measures for surfaces within reach and explain how to interpret free-hand measures for outdoor hills.

  16. Assessment of isometric muscle strength and rate of torque development with hand-held dynamometry: Test-retest reliability and relationship with gait velocity after stroke.

    Science.gov (United States)

    Mentiplay, Benjamin F; Tan, Dawn; Williams, Gavin; Adair, Brooke; Pua, Yong-Hao; Bower, Kelly J; Clark, Ross A

    2018-04-27

    Isometric rate of torque development examines how quickly force can be exerted and may resemble everyday task demands more closely than isometric strength. Rate of torque development may provide further insight into the relationship between muscle function and gait following stroke. Aims of this study were to examine the test-retest reliability of hand-held dynamometry to measure isometric rate of torque development following stroke, to examine associations between strength and rate of torque development, and to compare the relationships of strength and rate of torque development to gait velocity. Sixty-three post-stroke adults participated (60 years, 34 male). Gait velocity was assessed using the fast-paced 10 m walk test. Isometric strength and rate of torque development of seven lower-limb muscle groups were assessed with hand-held dynamometry. Intraclass correlation coefficients were calculated for reliability and Spearman's rho correlations were calculated for associations. Regression analyses using partial F-tests were used to compare strength and rate of torque development in their relationship with gait velocity. Good to excellent reliability was shown for strength and rate of torque development (0.82-0.97). Strong associations were found between strength and rate of torque development (0.71-0.94). Despite high correlations between strength and rate of torque development, rate of torque development failed to provide significant value to regression models that already contained strength. Assessment of isometric rate of torque development with hand-held dynamometry is reliable following stroke, however isometric strength demonstrated greater relationships with gait velocity. Further research should examine the relationship between dynamic measures of muscle strength/torque and gait after stroke. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. A Portable, Inexpensive, Nonmydriatic Fundus Camera Based on the Raspberry Pi® Computer

    Directory of Open Access Journals (Sweden)

    Bailey Y. Shen

    2017-01-01

    Full Text Available Purpose. Nonmydriatic fundus cameras allow retinal photography without pharmacologic dilation of the pupil. However, currently available nonmydriatic fundus cameras are bulky, not portable, and expensive. Taking advantage of recent advances in mobile technology, we sought to create a nonmydriatic fundus camera that was affordable and could be carried in a white coat pocket. Methods. We built a point-and-shoot prototype camera using a Raspberry Pi computer, an infrared-sensitive camera board, a dual infrared and white light light-emitting diode, a battery, a 5-inch touchscreen liquid crystal display, and a disposable 20-diopter condensing lens. Our prototype camera was based on indirect ophthalmoscopy with both infrared and white lights. Results. The prototype camera measured 133mm×91mm×45mm and weighed 386 grams. The total cost of the components, including the disposable lens, was $185.20. The camera was able to obtain good-quality fundus images without pharmacologic dilation of the pupils. Conclusion. A fully functional, inexpensive, handheld, nonmydriatic fundus camera can be easily assembled from a relatively small number of components. With modest improvements, such a camera could be useful for a variety of healthcare professionals, particularly those who work in settings where a traditional table-mounted nonmydriatic fundus camera would be inconvenient.

  18. Beyond Textbook Illustrations: Hand-Held Models of Ordered DNA and Protein Structures as 3D Supplements to Enhance Student Learning of Helical Biopolymers

    Science.gov (United States)

    Jittivadhna, Karnyupha; Ruenwongsa, Pintip; Panijpan, Bhinyo

    2010-01-01

    Textbook illustrations of 3D biopolymers on printed paper, regardless of how detailed and colorful, suffer from its two-dimensionality. For beginners, computer screen display of skeletal models of biopolymers and their animation usually does not provide the at-a-glance 3D perception and details, which can be done by good hand-held models. Here, we…

  19. Fundus albipunctatus associated with compound heterozygous mutations in RPE65

    DEFF Research Database (Denmark)

    Schatz, Patrik; Preising, Markus; Lorenz, Birgit

    2011-01-01

    To describe a family with an 18-year-old woman with fundus albipunctatus and compound heterozygous mutations in RPE65 whose unaffected parents and 1 female sibling harbored single heterozygous RPE65 mutations.......To describe a family with an 18-year-old woman with fundus albipunctatus and compound heterozygous mutations in RPE65 whose unaffected parents and 1 female sibling harbored single heterozygous RPE65 mutations....

  20. Application of RetCamⅡ in the screening of neonatal fundus disease

    Directory of Open Access Journals (Sweden)

    Zhi-Gang Xiao

    2013-08-01

    Full Text Available AIM: To investigate the safe and reliable examination method for neonatal fundus screening.METHODS: Fundus information of 2 836 neonates performed by RetCamⅡ in our hospital from January 1, 2012 to December 31, 2012 were retrospectively analyzed, including 1 625 cases(57.30%of premature infants which were first examined 1-4 weeks after birth and 1 211 cases(42.70%of term infants which were first examined within 4 weeks after birth.RESULTS: Totally 454 cases of abnormalfundus were found, including 207 cases(12.74%of retinopathy of prematurity(ROP, ROPⅠ in 118 cases(57%, ROPⅡ in 58 cases(28.02%, ROPⅢ in 23 cases(11.11%, ROPⅣ in 8 cases(3.86%, no case of ROPV. A total of 247(20.40%term infants had abnormal fundus, of which 68 cases(27.53%were developmental or hereditary disease, retinoblastoma in 1 case(0.40%, retinal hemorrhage in 102 cases(41.30%, retinal exudative changes in 68 cases(27.53%, optic atrophy in 5 cases(2.02%and optic disc edema in 3 cases(1.21%.CONCLUSION: Neonatal fundus diseases were so various and harmful that early screening should be attended to. Premature infants and term infants with high risk are treated as focus group of fundus screening and RetCamII examination is safe and effective.

  1. Effects of Carpal Tunnel Syndrome on adaptation of multi-digit forces to object mass distribution for whole-hand manipulation

    Directory of Open Access Journals (Sweden)

    Zhang Wei

    2012-11-01

    Full Text Available Abstract Background Carpal tunnel syndrome (CTS is a compression neuropathy of the median nerve that results in sensorimotor deficits in the hand. Until recently, the effects of CTS on hand function have been studied using mostly two-digit grip tasks. The purpose of this study was to investigate the coordination of multi-digit forces as a function of object center of mass (CM during whole-hand grasping. Methods Fourteen CTS patients and age- and gender-matched controls were instructed to grasp, lift, hold, and release a grip device with five digits for seven consecutive lifts while maintaining its vertical orientation. The object CM was changed by adding a mass at different locations at the base of the object. We measured forces and torques exerted by each digit and object kinematics and analyzed modulation of these variables to object CM at object lift onset and during object hold. Our task requires a modulation of digit forces at and after object lift onset to generate a compensatory moment to counteract the external moment caused by the added mass and to minimize object tilt. Results We found that CTS patients learned to generate a compensatory moment and minimized object roll to the same extent as controls. However, controls fully exploited the available degrees of freedom (DoF in coordinating their multi-digit forces to generate a compensatory moment, i.e., digit normal forces, tangential forces, and the net center of pressure on the finger side of the device at object lift onset and during object hold. In contrast, patients modulated only one of these DoFs (the net center of pressure to object CM by modulating individual normal forces at object lift onset. During object hold, however, CTS patients were able to modulate digit tangential force distribution to object CM. Conclusions Our findings suggest that, although CTS did not affect patients’ ability to perform our manipulation task, it interfered with the modulation of specific grasp

  2. Contact-free trans-pars-planar illumination enables snapshot fundus camera for nonmydriatic wide field photography.

    Science.gov (United States)

    Wang, Benquan; Toslak, Devrim; Alam, Minhaj Nur; Chan, R V Paul; Yao, Xincheng

    2018-06-08

    In conventional fundus photography, trans-pupillary illumination delivers illuminating light to the interior of the eye through the peripheral area of the pupil, and only the central part of the pupil can be used for collecting imaging light. Therefore, the field of view of conventional fundus cameras is limited, and pupil dilation is required for evaluating the retinal periphery which is frequently affected by diabetic retinopathy (DR), retinopathy of prematurity (ROP), and other chorioretinal conditions. We report here a nonmydriatic wide field fundus camera employing trans-pars-planar illumination which delivers illuminating light through the pars plana, an area outside of the pupil. Trans-pars-planar illumination frees the entire pupil for imaging purpose only, and thus wide field fundus photography can be readily achieved with less pupil dilation. For proof-of-concept testing, using all off-the-shelf components a prototype instrument that can achieve 90° fundus view coverage in single-shot fundus images, without the need of pharmacologic pupil dilation was demonstrated.

  3. Hand-held multi-DOF robotic forceps for neurosurgery designed for dexterous manipulation in deep and narrow space.

    Science.gov (United States)

    Okubo, Takuro; Harada, Kanako; Fujii, Masahiro; Tanaka, Shinichi; Ishimaru, Tetsuya; Iwanaka, Tadashi; Nakatomi, Hirohumi; Sora, Sigeo; Morita, Akio; Sugita, Naohiko; Mitsuishi, Mamoru

    2014-01-01

    Neurosurgical procedures require precise and dexterous manipulation of a surgical suture in narrow and deep spaces in the brain. This is necessary for surgical tasks such as the anastomosis of microscopic blood vessels and dura mater suturing. A hand-held multi-degree of freedom (DOF) robotic forceps was developed to aid the performance of such difficult tasks. The diameter of the developed robotic forceps is 3.5 mm, and its tip has three DOFs, namely, bending, rotation, and grip. Experimental results showed that the robotic forceps had an average needle insertion force of 1.7 N. Therefore, an increase in the needle insertion force is necessary for practical application of the developed device.

  4. Imperceptible watermarking for security of fundus images in tele-ophthalmology applications and computer-aided diagnosis of retina diseases.

    Science.gov (United States)

    Singh, Anushikha; Dutta, Malay Kishore

    2017-12-01

    The authentication and integrity verification of medical images is a critical and growing issue for patients in e-health services. Accurate identification of medical images and patient verification is an essential requirement to prevent error in medical diagnosis. The proposed work presents an imperceptible watermarking system to address the security issue of medical fundus images for tele-ophthalmology applications and computer aided automated diagnosis of retinal diseases. In the proposed work, patient identity is embedded in fundus image in singular value decomposition domain with adaptive quantization parameter to maintain perceptual transparency for variety of fundus images like healthy fundus or disease affected image. In the proposed method insertion of watermark in fundus image does not affect the automatic image processing diagnosis of retinal objects & pathologies which ensure uncompromised computer-based diagnosis associated with fundus image. Patient ID is correctly recovered from watermarked fundus image for integrity verification of fundus image at the diagnosis centre. The proposed watermarking system is tested in a comprehensive database of fundus images and results are convincing. results indicate that proposed watermarking method is imperceptible and it does not affect computer vision based automated diagnosis of retinal diseases. Correct recovery of patient ID from watermarked fundus image makes the proposed watermarking system applicable for authentication of fundus images for computer aided diagnosis and Tele-ophthalmology applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. A Case of Fundus Oculi Albinoticus Diagnosed as Angelman Syndrome by Genetic Testing

    Directory of Open Access Journals (Sweden)

    Yurie Fukiyama

    2018-02-01

    Full Text Available Purpose: To report a case of fundus oculi albinoticus diagnosed as Angelman syndrome (AS via genetic testing. Case Report: This study reports on a 4-year-old boy. Since he had been having respiratory disturbance since birth, he underwent a complete physical examination to investigate the cause. The results indicated that he had various brain congenital abnormalities, such as a thin corpus callosum, as well as hydronephrosis, an atrial septal defect, and skin similar to patients with fundus oculi albinoticus. Examination revealed bilateral fundus oculi albinoticus, mild iridic hypopigmentation, optic atrophy, and poor visual tracking. Genetic testing revealed a deletion in the Prader-Willi syndrome/AS region on chromosome 15, and together with the results of methylation analysis, his condition was diagnosed as AS. Follow-up examinations revealed no change in the fundus oculi albinoticus and optic atrophy, nor did they indicate poor visual tracking. Conclusions: When fundus oculi albinoticus and optic atrophy are observed in patients with multiple malformations, AS should be considered as a differential diagnosis.

  6. Fundus reflectance : historical and present ideas

    NARCIS (Netherlands)

    Berendschot, T.T.J.M.; Delint, P.J.; Norren, D. van

    2003-01-01

    In 1851 Helmholtz introduced the ophthalmoscope. The instrument allowed the observation of light reflected at the fundus. The development of this device was one of the major advancements in ophthalmology. Yet ophthalmoscopy allows only qualitative observation of the eye. Since 1950 attempts were

  7. Utility of hand-held echocardiography in outpatient pediatric cardiology management.

    Science.gov (United States)

    Riley, Alan; Sable, Craig; Prasad, Aparna; Spurney, Christopher; Harahsheh, Ashraf; Clauss, Sarah; Colyer, Jessica; Gierdalski, Marcin; Johnson, Ashley; Pearson, Gail D; Rosenthal, Joanna

    2014-12-01

    Adult patient series have shown hand-held echocardiography (echo) units (HHE) to be accurate for rapid diagnosis and triage. This is the first study to evaluate the ability of HHE to inform decision making in outpatient pediatric cardiology. New pediatric cardiology patients in outpatient clinics staffed by six pediatric cardiologists (experience 1-17 years) were prospectively enrolled if an echocardiogram (echo) was ordered during their initial visit. After history and physical examination and before a standard echo, the cardiologists performed a bedside HHE examination (GE Vscan 1.7-3.8 MHz), documented findings, and made a clinical decision. Diagnoses and decisions based on HHE were compared with final management after the standard echo. The study enrolled 101 subjects (ages 9 days to 19 years). The cardiologists considered HHE imaging adequate for decision making for 80 of the 101 subjects. For 77 of the 80 subjects with acceptable HHE imaging (68/68 normal and 9/12 abnormal standard echoes), the HHE-based primary diagnoses and decisions agreed with the final management. The sensitivity of HHE was 75 % (95 % confidence interval [CI] 43-94 %) and the positive predictive value 100 % (95 % CI 66-100 %) for pediatric heart disease. The agreement between standard echocardiography and HHE imaging was substantial (κ = 0.82). Excluding one of the least experienced cardiologists, HHE provided the basis for correct cardiac diagnoses and management for all the subjects with acceptable HHE imaging (58/58 normal and 9/9 abnormal echoes). In outpatient pediatric cardiology, HHE has potential as a tool to complement physical examination. Further investigation is needed to evaluate how value improves with clinical experience.

  8. Adaptive optics fundus images of cone photoreceptors in the macula of patients with retinitis pigmentosa

    Directory of Open Access Journals (Sweden)

    Tojo N

    2013-01-01

    Full Text Available Naoki Tojo, Tomoko Nakamura, Chiharu Fuchizawa, Toshihiko Oiwake, Atsushi HayashiDepartment of Ophthalmology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Toyama, JapanBackground: The purpose of this study was to examine cone photoreceptors in the macula of patients with retinitis pigmentosa using an adaptive optics fundus camera and to investigate any correlations between cone photoreceptor density and findings on optical coherence tomography and fundus autofluorescence.Methods: We examined two patients with typical retinitis pigmentosa who underwent ophthalmological examination, including measurement of visual acuity, and gathering of electroretinographic, optical coherence tomographic, fundus autofluorescent, and adaptive optics fundus images. The cone photoreceptors in the adaptive optics images of the two patients with retinitis pigmentosa and five healthy subjects were analyzed.Results: An abnormal parafoveal ring of high-density fundus autofluorescence was observed in the macula in both patients. The border of the ring corresponded to the border of the external limiting membrane and the inner segment and outer segment line in the optical coherence tomographic images. Cone photoreceptors at the abnormal parafoveal ring were blurred and decreased in the adaptive optics images. The blurred area corresponded to the abnormal parafoveal ring in the fundus autofluorescence images. Cone densities were low at the blurred areas and at the nasal and temporal retina along a line from the fovea compared with those of healthy controls. The results for cone spacing and Voronoi domains in the macula corresponded with those for the cone densities.Conclusion: Cone densities were heavily decreased in the macula, especially at the parafoveal ring on high-density fundus autofluorescence in both patients with retinitis pigmentosa. Adaptive optics images enabled us to observe in vivo changes in the cone photoreceptors of

  9. Use of fundus autofluorescence images to predict geographic atrophy progression.

    Science.gov (United States)

    Bearelly, Srilaxmi; Khanifar, Aziz A; Lederer, David E; Lee, Jane J; Ghodasra, Jason H; Stinnett, Sandra S; Cousins, Scott W

    2011-01-01

    Fundus autofluorescence imaging has been shown to be helpful in predicting progression of geographic atrophy (GA) secondary to age-related macular degeneration. We assess the ability of fundus autofluorescence imaging to predict rate of GA progression using a simple categorical scheme. Subjects with GA secondary to age-related macular degeneration with fundus autofluorescence imaging acquired at least 12 months apart were included. Rim area focal hyperautofluorescence was defined as percentage of the 500-μm-wide margin bordering the GA that contained increased autofluorescence. Rim area focal hyperautofluorescence on baseline fundus autofluorescence images was assessed and categorized depending on the extent of rim area focal hyperautofluorescence (Category 1: ≤33%; Category 2: between 33 and 67%; Category 3: ≥67%). Total GA areas at baseline and follow-up were measured to calculate change in GA progression. Forty-five eyes of 45 subjects were included; average duration of follow-up was 18.5 months. Median growth rates differed among categories of baseline rim area focal hyperautofluorescence (P = 0.01 among Categories 1, 2, and 3; P = 0.008 for Category 1 compared with Category 3, Jonckheere-Terpstra test). A simple categorical scheme that stratifies the amount of increased autofluorescence in the 500-μm margin bordering GA may be used to differentiate faster and slower progressors.

  10. Fundus Findings in Dengue Fever: A Case Report

    Directory of Open Access Journals (Sweden)

    Berna Şahan

    2015-10-01

    Full Text Available Dengue fever is a flavivirus infection transmitted through infected mosquitoes, and is endemic in Southeast Asia, Central and South America, the Pacific, Africa and the Eastern Mediterranean region. A 41-year-old male patient had visual impairment after travelling to Thailand, which is one of the endemic areas. Cotton wool spots were observed on fundus examination. Fundus fluorescein angiography showed minimal vascular leakage from areas near the cotton wool spots and dot hemorrhages in the macula. Dengue fever should be considered in patients with visual complaints who traveled to endemic areas of dengue fever. (Turk J Ophthalmol 2015; 45: 223-225

  11. Growing expertise in Africa: CERN-UNESCO's 3rd Digital Library School

    CERN Multimedia

    Joannah Caborn Wengler

    2012-01-01

    The third in the series of CERN-UNESCO African Schools on Digital Libraries took place in Dakar, Senegal, in November last year. The School represents an important opportunity for CERN to contribute to a global exchange of knowledge, skills and culture.   Ludmila Marian assisting participants during a hands-on computer session. More photographs available here. After Rwanda and Morocco, this time it was Senegal's turn to host the Digital Library School, the third of its kind, held from 21 to 25 November 2011. Participants from seven African French-speaking countries met at the Université Cheikh Anta Diop in Dakar to learn about digital libraries and the importance of new technologies in the dissemination of knowledge by libraries. The School outlined the principles of digital information management and showcased the Invenio software, developed by CERN to manage digital libraries and freely available as Open Source software. The series of Schools, which combine in...

  12. Calculation of induced current densities and specific absorption rates (SAR) for pregnant women exposed to hand-held metal detectors

    International Nuclear Information System (INIS)

    Kainz, Wolfgang; Chan, Dulciana D; Casamento, Jon P; Bassen, Howard I

    2003-01-01

    The finite difference time domain (FDTD) method in combination with a well established frequency scaling method was used to calculate the internal fields and current densities induced in a simple model of a pregnant woman and her foetus, when exposed to hand-held metal detectors. The pregnant woman and foetus were modelled using a simple semi-heterogeneous model in 10 mm resolution, consisting of three different types of tissue. The model is based on the scanned shape of a pregnant woman in the 34th gestational week. Nine different representative models of hand-held metal detectors operating in the frequency range from 8 kHz to 2 MHz were evaluated. The metal detectors were placed directly on the abdomen of the computational model with a spacing of 1 cm. Both the induced current density and the specific absorption rate (SAR) are well below the recommended limits for exposure of the general public published in the ICNIRP Guidelines and the IEEE C95.1 Standard. The highest current density is 8.3 mA m -2 and the highest SAR is 26.5 μW kg -1 . Compared to the limits for the induced current density recommended in the ICNIRP Guidelines, a minimum safety factor of 3 exists. Compared to the IEEE C95.1 Standard, a safety factor of 60,000 for the specific absorption rate was found. Based on the very low specific absorption rate and an induced current density below the recommended exposure limits, significant temperature rise or nerve stimulation in the pregnant woman or in the foetus can be excluded

  13. Analysis of phakic before intraocular lens implantation for fundus examination

    OpenAIRE

    Juan Chen; Zhong-Ping Chen; Rui-Ling Zhu

    2014-01-01

    AIM:To investigate the findings of the eyes which were examined preoperatively by three mirror contact lens before the implantation of implantable collamer lens(ICL). To analysis the retinal pathological changes and to explore the clinical analysis of early diagnosis and treatment in retinopathy on fundus examination before operation. METHODS:The retrospective case series study included 127 eyes of 64 patients who underwent phakic intraocular lens implantation were received the fundus examina...

  14. Krypton red laser photocoagulation of the ocular fundus. 1982.

    Science.gov (United States)

    Yannuzzi, Lawrence A; Shakin, Jeffrey L

    2012-02-01

    The theoretical rationale, the histopathologic evidence, and the preliminary clinical studies related to krypton red laser (KRL) photocoagulation of the ocular fundus are reviewed. The authors report on their experience with currently available laser systems using this wavelength (647.1 nm) for photocoagulation of retinal vascular proliferative diseases and chorioretinal diseases associated with exudative manifestations. A histopathologic and clinical comparison of argon blue-green laser (ABGL), the pure argon green laser (AGL), and the krypton yellow laser (KYL), with reference to photocoagulation treatment of the ocular fundus is also discussed.

  15. Perceiving the vertical distances of surfaces by means of a hand-held probe.

    Science.gov (United States)

    Chan, T C; Turvey, M T

    1991-05-01

    Nine experiments were conducted on the haptic capacity of people to perceive the distances of horizontal surfaces solely on the basis of mechanical stimulation resulting from contacting the surfaces with a vertically held rod. Participants touched target surfaces with rods inside a wooden cabinet and reported the perceived surface location with an indicator outside the cabinet. The target surface, rod, and the participant's hand were occluded, and the sound produced in exploration was muffled. Properties of the probe (length, mass, moment of inertia, center of mass, and shape) were manipulated, along with surface distance and the method and angle of probing. Results suggest that for the most common method of probing, namely, tapping, perceived vertical distance is specific to a particular relation among the rotational inertia of the probe, the distance of the point of contact with the surface from the probe's center of percussion, and the inclination at contact of the probe to the surface. They also suggest that the probe length and the distance probed are independently perceivable. The results were discussed in terms of information specificity versus percept-percept coupling and parallels between selective attention in haptic and visual perception.

  16. The hand of birds revealed by early ostrich embryos

    Science.gov (United States)

    Feduccia, Alan; Nowicki, Julie

    2002-08-01

    The problem of resolving the homology of the digits of the avian hand has been framed as a conflict between paleontological and embryological evidence, the former thought to support a hand composed of digits I, II, III, because of similarity of the phalangeal formulae of the earliest known bird Archaeopteryx to that of Mesozoic pentadactyl archosaurs, while embryological evidence has traditionally favored a II, III, IV avian hand. We have identified the critical developmental period for the major features of the avian skeleton in a primitive bird, the ostrich. Analysis of digit anlagen in the avian hand has revealed those for digits/metacarpals I and V, thus confirming previous embryological studies that indirectly suggested that the avian hand comprises digits II, III, IV, and was primitively pentadactyl.

  17. Classification of diabetic retinopathy using fractal dimension analysis of eye fundus image

    Science.gov (United States)

    Safitri, Diah Wahyu; Juniati, Dwi

    2017-08-01

    Diabetes Mellitus (DM) is a metabolic disorder when pancreas produce inadequate insulin or a condition when body resist insulin action, so the blood glucose level is high. One of the most common complications of diabetes mellitus is diabetic retinopathy which can lead to a vision problem. Diabetic retinopathy can be recognized by an abnormality in eye fundus. Those abnormalities are characterized by microaneurysms, hemorrhage, hard exudate, cotton wool spots, and venous's changes. The diabetic retinopathy is classified depends on the conditions of abnormality in eye fundus, that is grade 1 if there is a microaneurysm only in the eye fundus; grade 2, if there are a microaneurysm and a hemorrhage in eye fundus; and grade 3: if there are microaneurysm, hemorrhage, and neovascularization in the eye fundus. This study proposed a method and a process of eye fundus image to classify of diabetic retinopathy using fractal analysis and K-Nearest Neighbor (KNN). The first phase was image segmentation process using green channel, CLAHE, morphological opening, matched filter, masking, and morphological opening binary image. After segmentation process, its fractal dimension was calculated using box-counting method and the values of fractal dimension were analyzed to make a classification of diabetic retinopathy. Tests carried out by used k-fold cross validation method with k=5. In each test used 10 different grade K of KNN. The accuracy of the result of this method is 89,17% with K=3 or K=4, it was the best results than others K value. Based on this results, it can be concluded that the classification of diabetic retinopathy using fractal analysis and KNN had a good performance.

  18. Into the Wild: Neuroergonomic Differentiation of Hand-Held and Augmented Reality Wearable Displays during Outdoor Navigation with Functional Near Infrared Spectroscopy.

    Science.gov (United States)

    McKendrick, Ryan; Parasuraman, Raja; Murtza, Rabia; Formwalt, Alice; Baccus, Wendy; Paczynski, Martin; Ayaz, Hasan

    2016-01-01

    Highly mobile computing devices promise to improve quality of life, productivity, and performance. Increased situation awareness and reduced mental workload are two potential means by which this can be accomplished. However, it is difficult to measure these concepts in the "wild". We employed ultra-portable battery operated and wireless functional near infrared spectroscopy (fNIRS) to non-invasively measure hemodynamic changes in the brain's Prefrontal cortex (PFC). Measurements were taken during navigation of a college campus with either a hand-held display, or an Augmented reality wearable display (ARWD). Hemodynamic measures were also paired with secondary tasks of visual perception and auditory working memory to provide behavioral assessment of situation awareness and mental workload. Navigating with an augmented reality wearable display produced the least workload during the auditory working memory task, and a trend for improved situation awareness in our measures of prefrontal hemodynamics. The hemodynamics associated with errors were also different between the two devices. Errors with an augmented reality wearable display were associated with increased prefrontal activity and the opposite was observed for the hand-held display. This suggests that the cognitive mechanisms underlying errors between the two devices differ. These findings show fNIRS is a valuable tool for assessing new technology in ecologically valid settings and that ARWDs offer benefits with regards to mental workload while navigating, and potentially superior situation awareness with improved display design.

  19. [Fluorescein angiography and optical coherence tomography findings in central fundus of myopic patients].

    Science.gov (United States)

    Avetisov, S E; Budzinskaya, M V; Zhabina, O A; Andreeva, I V; Plyukhova, A A; Kobzova, M V; Musaeva, G M

    2015-01-01

    Myopia prevalence grows alike in many countries, including Russia, regardless of geographical and population conditions. to assess fundus changes in myopic patients at different ocular axial lengths by means of modern diagnostic tools. The study enrolled 97 patients (194 eyes) aged 45 ± 20.17 years with myopia of different degrees. Besides a standard ophthalmic examination, all patients underwent fundus fluorescein angiography and optical coherence tomography. The occurrence of retinal pigment epithelium (RPE) atrophy (diffuse or focal) has been shown to increase with increasing ocular axial length. Only 27 eyes (28.1%) appeared intact. As myopia progression implies axial growth of the eye, it is associated with a more severe decrease in choroid, RPE, and photoreceptor layer thicknesses: the longer the anterior-posterior axis, the thinner the above mentioned fundus structures. Age-related changes in the fundus are also likely to be more pronounced in longer axes. Myopic traction maculopathy, which in our case appeared the main cause of increased retinal thickness, was diagnosed in 105 eyes, "outer" macular retinoschisis--in 40 eyes. Thus, modern diagnostic tools, such as fluorescein angiography and optical coherence tomography, enable objective assessment of the central fundus.

  20. The effects of fundus photography on the multifocal electroretinogram.

    Science.gov (United States)

    Suresh, Sandip; Tienor, Brian J; Smith, Scott D; Lee, Michael S

    2016-02-01

    To determine the effect of flash fundus photography (FFP) on the multifocal electroretinogram (mfERG). Ten subjects underwent mfERG testing on three separate dates. Subjects received either mfERG without FFP, mfERG at 5 and 15 min after FFP, or mfERG at 30 and 45 min after FFP on each date. The FFP groups received 10 fundus photographs followed by mfERG testing, first of the right eye then of the left eye 10 min later. Data were averaged and analyzed in six concentric rings at each time point. Average amplitude and implicit times of the N1, P1, and N2 peaks for each concentric ring at each time point after FFP were compared to baseline. Flash fundus photography did not lead to a significant change of amplitude or implicit times of N1, P1, or N2 at 5 min after light exposure. These findings suggest that it is acceptable to perform mfERG testing without delay after performance of FFP.

  1. Imaging autofluorescence temporal signatures of the human ocular fundus in vivo

    Science.gov (United States)

    Papour, Asael; Taylor, Zachary; Stafsudd, Oscar; Tsui, Irena; Grundfest, Warren

    2015-11-01

    We demonstrate real-time in vivo fundus imaging capabilities of our fluorescence lifetime imaging technology for the first time. This implementation of lifetime imaging uses light emitting diodes to capture full-field images capable of showing direct tissue contrast without executing curve fitting or lifetime calculations. Preliminary results of fundus images are presented, investigating autofluorescence imaging potential of various retina biomarkers for early detection of macular diseases.

  2. The Portable Dynamic Fundus Instrument: Uses in telemedicine and research

    Science.gov (United States)

    Hunter, Norwood; Caputo, Michael; Billica, Roger; Taylor, Gerald; Gibson, C. Robert; Manuel, F. Keith; Mader, Thomas; Meehan, Richard

    1994-01-01

    For years ophthalmic photographs have been used to track the progression of many ocular diseases such as macular degeneration and glaucoma as well as the ocular manifestations of diabetes, hypertension, and hypoxia. In 1987 a project was initiated at the Johnson Space Center (JSC) to develop a means of monitoring retinal vascular caliber and intracranial pressure during space flight. To conduct telemedicine during space flight operations, retinal images would require real-time transmissions from space. Film-based images would not be useful during in-flight operations. Video technology is beneficial in flight because the images may be acquired, recorded, and transmitted to the ground for rapid computer digital image processing and analysis. The computer analysis techniques developed for this project detected vessel caliber changes as small as 3 percent. In the field of telemedicine, the Portable Dynamic Fundus Instrument demonstrates the concept and utility of a small, self-contained video funduscope. It was used to record retinal images during the Gulf War and to transmit retinal images from the Space Shuttle Columbia during STS-50. There are plans to utilize this device to provide a mobile ophthalmic screening service in rural Texas. In the fall of 1993 a medical team in Boulder, Colorado, will transmit real-time images of the retina during remote consultation and diagnosis. The research applications of this device include the capability of operating in remote locations or small, confined test areas. There has been interest shown utilizing retinal imaging during high-G centrifuge tests, high-altitude chamber tests, and aircraft flight tests. A new design plan has been developed to incorporate the video instrumentation into face-mounted goggle. This design would eliminate head restraint devices, thus allowing full maneuverability to the subjects. Further development of software programs will broaden the application of the Portable Dynamic Fundus Instrument in

  3. Cognitive Hacking and Digital Government: Digital Identity

    OpenAIRE

    Paul Thompson

    2004-01-01

    Recently the National Center for Digital Government held a workshop on "The Virtual Citizen: Identity, Autonomy, and Accountability: A Civic Scenario Exploration of the Role of Identity in On-Line. Discussions at the workshop focused on five scenarios for future authentication policies with respect to digital identity. The underlying technologies considered for authentication were: biometrics: cryptography, with a focus on digital signatures; secure processing/computation; and reputation syst...

  4. Adaptive optics fundus images of cone photoreceptors in the macula of patients with retinitis pigmentosa.

    Science.gov (United States)

    Tojo, Naoki; Nakamura, Tomoko; Fuchizawa, Chiharu; Oiwake, Toshihiko; Hayashi, Atsushi

    2013-01-01

    The purpose of this study was to examine cone photoreceptors in the macula of patients with retinitis pigmentosa using an adaptive optics fundus camera and to investigate any correlations between cone photoreceptor density and findings on optical coherence tomography and fundus autofluorescence. We examined two patients with typical retinitis pigmentosa who underwent ophthalmological examination, including measurement of visual acuity, and gathering of electroretinographic, optical coherence tomographic, fundus autofluorescent, and adaptive optics fundus images. The cone photoreceptors in the adaptive optics images of the two patients with retinitis pigmentosa and five healthy subjects were analyzed. An abnormal parafoveal ring of high-density fundus autofluorescence was observed in the macula in both patients. The border of the ring corresponded to the border of the external limiting membrane and the inner segment and outer segment line in the optical coherence tomographic images. Cone photoreceptors at the abnormal parafoveal ring were blurred and decreased in the adaptive optics images. The blurred area corresponded to the abnormal parafoveal ring in the fundus autofluorescence images. Cone densities were low at the blurred areas and at the nasal and temporal retina along a line from the fovea compared with those of healthy controls. The results for cone spacing and Voronoi domains in the macula corresponded with those for the cone densities. Cone densities were heavily decreased in the macula, especially at the parafoveal ring on high-density fundus autofluorescence in both patients with retinitis pigmentosa. Adaptive optics images enabled us to observe in vivo changes in the cone photoreceptors of patients with retinitis pigmentosa, which corresponded to changes in the optical coherence tomographic and fundus autofluorescence images.

  5. Determining degree of optic nerve edema from color fundus photography

    Science.gov (United States)

    Agne, Jason; Wang, Jui-Kai; Kardon, Randy H.; Garvin, Mona K.

    2015-03-01

    Swelling of the optic nerve head (ONH) is subjectively assessed by clinicians using the Frisén scale. It is believed that a direct measurement of the ONH volume would serve as a better representation of the swelling. However, a direct measurement requires optic nerve imaging with spectral domain optical coherence tomography (SD-OCT) and 3D segmentation of the resulting images, which is not always available during clinical evaluation. Furthermore, telemedical imaging of the eye at remote locations is more feasible with non-mydriatic fundus cameras which are less costly than OCT imagers. Therefore, there is a critical need to develop a more quantitative analysis of optic nerve swelling on a continuous scale, similar to SD-OCT. Here, we select features from more commonly available 2D fundus images and use them to predict ONH volume. Twenty-six features were extracted from each of 48 color fundus images. The features include attributes of the blood vessels, optic nerve head, and peripapillary retina areas. These features were used in a regression analysis to predict ONH volume, as computed by a segmentation of the SD-OCT image. The results of the regression analysis yielded a mean square error of 2.43 mm3 and a correlation coefficient between computed and predicted volumes of R = 0:771, which suggests that ONH volume may be predicted from fundus features alone.

  6. Coaxial fundus camera for opthalmology

    Science.gov (United States)

    de Matos, Luciana; Castro, Guilherme; Castro Neto, Jarbas C.

    2015-09-01

    A Fundus Camera for ophthalmology is a high definition device which needs to meet low light illumination of the human retina, high resolution in the retina and reflection free image1. Those constraints make its optical design very sophisticated, but the most difficult to comply with is the reflection free illumination and the final alignment due to the high number of non coaxial optical components in the system. Reflection of the illumination, both in the objective and at the cornea, mask image quality, and a poor alignment make the sophisticated optical design useless. In this work we developed a totally axial optical system for a non-midriatic Fundus Camera. The illumination is performed by a LED ring, coaxial with the optical system and composed of IR of visible LEDs. The illumination ring is projected by the objective lens in the cornea. The Objective, LED illuminator, CCD lens are coaxial making the final alignment easily to perform. The CCD + capture lens module is a CCTV camera with autofocus and Zoom built in, added to a 175 mm focal length doublet corrected for infinity, making the system easily operated and very compact.

  7. Drift from the Use of Hand-Held Knapsack Pesticide Sprayers in Boyacá (Colombian Andes).

    Science.gov (United States)

    García-Santos, Glenda; Feola, Giuseppe; Nuyttens, David; Diaz, Jaime

    2016-05-25

    Offsite pesticide losses in tropical mountainous regions have been little studied. One example is measuring pesticide drift soil deposition, which can support pesticide risk assessment for surface water, soil, bystanders, and off-target plants and fauna. This is considered a serious gap, given the evidence of pesticide-related poisoning in those regions. Empirical data of drift deposition of a pesticide surrogate, Uranine tracer, within one of the highest potato-producing regions in Colombia, characterized by small plots and mountain orography, is presented. High drift values encountered in this study reflect the actual spray conditions using hand-held knapsack sprayers. Comparison between measured and predicted drift values using three existing empirical equations showed important underestimation. However, after their optimization based on measured drift information, the equations showed a strong predictive power for this study area and the study conditions. The most suitable curve to assess mean relative drift was the IMAG calculator after optimization.

  8. 3D Scan of Ornamental Column (huabiao Using Terrestrial LiDAR and Hand-held Imager

    Directory of Open Access Journals (Sweden)

    W. Zhang

    2015-08-01

    Full Text Available In ancient China, Huabiao was a type of ornamental column used to decorate important buildings. We carried out 3D scan of a Huabiao located in Peking University, China. This Huabiao was built no later than 1742. It is carved by white marble, 8 meters in height. Clouds and various postures of dragons are carved on its body. Two instruments were used to acquire the point cloud of this Huabiao, a terrestrial LiDAR (Riegl VZ-1000 and a hand-held imager (Mantis Vision F5. In this paper, the details of the experiment were described, including the differences between these two instruments, such as working principle, spatial resolution, accuracy, instrument dimension and working flow. The point clouds obtained respectively by these two instruments were compared, and the registered point cloud of Huabiao was also presented. These should be of interest and helpful for the research communities of archaeology and heritage.

  9. Feasibility and quality of nonmydriatic fundus photography in children

    Science.gov (United States)

    Toffoli, Daniela; Bruce, Beau B.; Lamirel, Cédric; Henderson, Amanda D.; Newman, Nancy J.; Biousse, Valérie

    2011-01-01

    Purpose Ocular funduscopic examination is difficult in young children and is rarely attempted by nonophthalmologists. Our objective was to determine the feasibility of reliably obtaining high-quality nonmydriatic fundus photographs in children. Methods Nonmydriatic fundus photographs were obtained in both eyes of children seen in a pediatric ophthalmology clinic. Ease of fundus photography was recorded on a 10-point Likert scale (10 = very easy). Quality was graded from 1 to 5 (1, inadequate for any diagnostic purpose; 2, unable to exclude all emergent findings; 3, only able to exclude emergent findings; 4, not ideal, but still able to exclude subtle findings; and 5, ideal quality). The primary outcome measure was image quality by age. Results A total of 878 photographs of 212 children (median age, 6 years; range,1-18 years) were included. Photographs of at least one eye were obtained in 190 children (89.6%) and in both eyes in 181 (85.3%). Median rating for ease of photography was 7. Photographs of some clinical value (grade ≥2) were obtained in 33% of children 3 years. High-quality photographs (grade 4 or 5) were obtained in both eyes in 7% of children <3 years, 57% of children ≥3 to <7 years, 85% of children ≥7 to <9 years, and 65% of children ≥9 years. The youngest patient with high-quality photographs in both eyes was 22 months. Conclusions Nonmydriatic fundus photographs of adequate quality can be obtained in children over age 3 and in some children as young as 22 months. PMID:22153402

  10. Quantitative Fundus Autofluorescence in Recessive Stargardt Disease

    OpenAIRE

    Burke, Tomas R.; Duncker, Tobias; Woods, Russell L.; Greenberg, Jonathan P.; Zernant, Jana; Tsang, Stephen H.; Smith, R. Theodore; Allikmets, Rando; Sparrow, Janet R.; Delori, François C.

    2014-01-01

    Quantitative fundus autofluorescence (qAF) is significantly increased in Stargardt disease, consistent with previous reports of increased RPE lipofuscin. QAF will help to establish genotype-phenotype correlations and may serve as an outcome measure in clinical trials.

  11. Hand held control unit for controlling a display screen-oriented computer game, and a display screen-oriented computer game having one or more such control units

    NARCIS (Netherlands)

    2001-01-01

    A hand-held control unit is used to control a display screen-oriented computer game. The unit comprises a housing with a front side, a set of control members lying generally flush with the front side for through actuating thereof controlling actions of in-game display items, and an output for

  12. Analysis of visual pigment by fundus autofluorescence.

    NARCIS (Netherlands)

    Theelen, T.; Berendschot, T.T.; Boon, C.J.F.; Hoyng, C.B.; Klevering, B.J.

    2008-01-01

    This study investigated changes of short-wavelength fundus autofluorescence (SW-AF) by retinal bleaching effects. All measurements were performed with the Heidelberg Retina Angiograph 2 (HRA 2). Initially, experimental imaging was done on a healthy eye after dark adaptation. Photopigment was

  13. First Invenio Workshop: CERN’s digital library software ten years on

    CERN Multimedia

    Joannah Caborn Wengler

    2012-01-01

    To mark the release of Invenio 1.0, the first User Group Workshop was held last week, with more than 40 developers, system administrators and librarians from 14 different countries attending. The participants were able to catch up on developments in CERN’s digital library software and get a glimpse of where it's going next.   “This is the first time we’ve held such a big workshop,” explains Jean-Yves Le Meur, head of Digital Library Services. “There was a lot of demand for an event like this, and bringing out version 1.0 of Invenio was an obvious time to do it.” Ask him what’s new in version 1.0 and he opens his eyes wide. “There’s so much, it’s hard to summarise. One key improvement is that the code and the database are stable, well tested and optimised, which makes the software more efficient.” The participants, on the other hand, highlight new features coming up in Invenio...

  14. Flexible CMOS low-noise amplifiers for beyond-3G wireless hand-held devices

    Science.gov (United States)

    Becerra-Alvarez, Edwin C.; Sandoval-Ibarra, Federico; de la Rosa, José M.

    2009-05-01

    This paper explores the use of reconfigurable Low-Noise Amplifiers (LNAs) for the implementation of CMOS Radio Frequency (RF) front-ends in the next generation of multi-standard wireless transceivers. Main circuit strategies reported so far for multi-standard LNAs are reviewed and a novel flexible LNA intended for Beyond-3G RF hand-held terminals is presented. The proposed LNA circuit consists of a two-stage topology that combines inductive-source degeneration with PMOS-varactor based tuning network and a programmable load to adapt its performance to different standard specifications without penalizing the circuit noise and with a reduced number of inductors as compared to previous reported reconfigurable LNAs. The circuit has been designed in a 90-nm CMOS technology to cope with the requirements of the GSM, WCDMA, Bluetooth and WLAN (IEEE 802.11b-g) standards. Simulation results, including technology and packaging parasitics, demonstrate correct operation of the circuit for all the standards under study, featuring NF13.3dB and IIP3>10.9dBm, over a 1.85GHz-2.4GHz band, with an adaptive power consumption between 17mW and 22mW from a 1-V supply voltage. Preliminary experimental measurements are included, showing a correct reconfiguration operation within the operation band.

  15. Fundus autofluorescence findings in a mouse model of retinal detachment.

    Science.gov (United States)

    Secondi, Roberta; Kong, Jian; Blonska, Anna M; Staurenghi, Giovanni; Sparrow, Janet R

    2012-08-07

    Fundus autofluorescence (fundus AF) changes were monitored in a mouse model of retinal detachment (RD). RD was induced by transscleral injection of hyaluronic acid (Healon) or sterile balanced salt solution (BSS) into the subretinal space of 4-5-day-old albino Abca4 null mutant and Abca4 wild-type mice. Images acquired by confocal scanning laser ophthalmoscopy (Spectralis HRA) were correlated with spectral domain optical coherence tomography (SD-OCT), infrared reflectance (IR), fluorescence spectroscopy, and histologic analysis. Results. In the area of detached retina, multiple hyperreflective spots in IR images corresponded to punctate areas of intense autofluorescence visible in fundus AF mode. The puncta exhibited changes in fluorescence intensity with time. SD-OCT disclosed undulations of the neural retina and hyperreflectivity of the photoreceptor layer that likely corresponded to histologically visible photoreceptor cell rosettes. Fluorescence emission spectra generated using flat-mounted retina, and 488 and 561 nm excitation, were similar to that of RPE lipofuscin. With increased excitation wavelength, the emission maximum shifted towards longer wavelengths, a characteristic typical of fundus autofluorescence. In detached retinas, hyper-autofluorescent spots appeared to originate from photoreceptor outer segments that were arranged within retinal folds and rosettes. Consistent with this interpretation is the finding that the autofluorescence was spectroscopically similar to the bisretinoids that constitute RPE lipofuscin. Under the conditions of a RD, abnormal autofluorescence may arise from excessive production of bisretinoid by impaired photoreceptor cells.

  16. Thresholds of whole-blood β-hydroxybutyrate and glucose concentrations measured with an electronic hand-held device to identify ovine hyperketonemia.

    Science.gov (United States)

    Pichler, M; Damberger, A; Schwendenwein, I; Gasteiner, J; Drillich, M; Iwersen, M

    2014-03-01

    Metabolic disorders, especially hyperketonemia, are very common in dairy sheep. The whole-blood concentrations of β-hydroxybutyrate (BHBA) and glucose can be determined by commercially available electronic hand-held devices, which are used in human medicine and for the detection of ketosis in dairy cows. The aim of this study was to evaluate the suitability of the hand-held device Precision Xceed (PX; Abbott Diabetes Care Inc., Abbott Park, IL) to detect hyperketonemia in ewes. An additional objective of this study was to evaluate the agreement between samples obtained by minimal invasive venipuncture of an ear vein and measurements of whole-blood samples from the jugular vein (vena jugularis, v. jug.). Blood samples taken from the v. jug. were collected from 358 ewes on 4 different farms. These samples and a blood drop obtained from an ear vein were analyzed simultaneously on farm with the PX. For method comparison, the samples obtained from the v. jug. were also analyzed by standard methods, which served as the gold standard at the Central Laboratory of the University of Veterinary Medicine Vienna, Austria. The correlation coefficients between the serum BHBA concentration and the concentrations measured with the hand-held meter in the whole blood from an ear vein and the v. jug. were 0.94 and 0.96, respectively. The correlation coefficients of plasma and whole-blood glucose concentration were 0.68 for the v. jug. and 0.47 for the ear vein. The mean glucose concentration was significantly lower in animals classified as hyperketonemic (BHBA ≥ 1.6 mmol/L) compared with healthy ewes. Whole-blood concentrations of BHBA and glucose measured with the PX from v. jug. showed a constant negative bias of 0.15 mmol/L and 8.4 mg/dL, respectively. Hence, a receiver operating characteristic analysis was performed to determine thresholds for the PX to detect hyperketonemia in ewes. This resulted in thresholds for moderate ketosis of BHBA concentrations of 0.7 mmol/L in blood

  17. Comparison of optical coherence tomography and fundus photography for measuring the optic disc size.

    Science.gov (United States)

    Neubauer, Aljoscha S; Krieglstein, Tina R; Chryssafis, Christos; Thiel, Martin; Kampik, Anselm

    2006-01-01

    To assess the agreement and repeatability of optic nerve head (ONH) size measurements by optical coherence tomography (OCT) as compared to conventional planimetry of fundus photographs in normal eyes. For comparison with planimetry the absolute size of the ONH of 25 eyes from 25 normal subjects were measured by both OCT and digital fundus photography (Zeiss FF camera 450). Repeatability of automated Stratus OCT measurements were investigated by repeatedly measuring the optic disc in five normal subjects. Mean disc size was 1763 +/- 186 vertically and 1632 +/- 160 microm horizontally on planimetry. On OCT, values of 1772 +/- 317 microm vertically (p = 0.82) and a significantly smaller horizontal diameter of 1492 +/- 302 microm (p = 0.04) were obtained. The 95% limits of agreement were (-546 microm; +527 microm) for vertical and (-502 microm; +782 microm) for horizontal planimetric compared to OCT measurements. In some cases large discrepancies existed. Repeatability of automatic measurements of the optic disc by OCT was moderately good with intra-class correlation coefficients (ICC) of 0.78 horizontally and 0.83 vertically. The coefficient of repeatability indicating instrument precision was 80 microm for horizontal and 168 microm for vertical measurements. OCT can be used to determine optic disc margins in moderate agreement with planimetry in normal subjects. However, in some cases significant disagreement with photographic assessment may occur making manual inspection advisable. Automatic disc detection by OCT is moderately repeatable.

  18. Adaptive optics scanning laser ophthalmoscopy in fundus imaging, a review and update

    OpenAIRE

    Zhang, Bing; Li, Ni; Kang, Jie; He, Yi; Chen, Xiao-Ming

    2017-01-01

    Adaptive optics scanning laser ophthalmoscopy (AO-SLO) has been a promising technique in funds imaging with growing popularity. This review firstly gives a brief history of adaptive optics (AO) and AO-SLO. Then it compares AO-SLO with conventional imaging methods (fundus fluorescein angiography, fundus autofluorescence, indocyanine green angiography and optical coherence tomography) and other AO techniques (adaptive optics flood-illumination ophthalmoscopy and adaptive optics optical coherenc...

  19. Cost Model for Digital Curation: Cost of Digital Migration

    DEFF Research Database (Denmark)

    Kejser, Ulla Bøgvad; Nielsen, Anders Bo; Thirifays, Alex

    2009-01-01

    The Danish Ministry of Culture is currently funding a project to set up a model for costing preservation of digital materials held by national cultural heritage institutions. The overall objective of the project is to provide a basis for comparing and estimating future financial requirements...... for digital preservation and to increase cost effectiveness of digital preservation activities. In this study we describe an activity based costing methodology for digital preservation based on the OAIS Reference Model. In order to estimate the cost of digital migrations we have identified cost critical...

  20. Ocular Fundus Photography as a Tool to Study Stroke and Dementia.

    Science.gov (United States)

    Cheung, Carol Y; Chen, Christopher; Wong, Tien Y

    2015-10-01

    Although cerebral small vessel disease has been linked to stroke and dementia, due to limitations of current neuroimaging technology, direct in vivo visualization of changes in the cerebral small vessels (e.g., cerebral arteriolar narrowing, tortuous microvessels, blood-brain barrier damage, capillary microaneurysms) is difficult to achieve. As the retina and the brain share similar embryological origin, anatomical features, and physiologic properties with the cerebral small vessels, the retinal vessels offer a unique and easily accessible "window" to study the correlates and consequences of cerebral small vessel diseases in vivo. The retinal microvasculature can be visualized, quantified and monitored noninvasively using ocular fundus photography. Recent clinic- and population-based studies have demonstrated a close link between retinal vascular changes seen on fundus photography and stroke and dementia, suggesting that ocular fundus photography may provide insights to the contribution of microvascular disease to stroke and dementia. In this review, we summarize current knowledge on retinal vascular changes, such as retinopathy and changes in retinal vascular measures with stroke and dementia as well as subclinical makers of cerebral small vessel disease, and discuss the possible clinical implications of these findings in neurology. Studying pathologic changes of retinal blood vessels may be useful for understanding the etiology of various cerebrovascular conditions; hence, ocular fundus photography can be potentially translated into clinical practice. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  1. PATTERNS OF FUNDUS AUTOFLUORESCENCE DEFECTS IN NEOVASCULAR AGE-RELATED MACULAR DEGENERATION SUBTYPES.

    Science.gov (United States)

    Ozkok, Ahmet; Sigford, Douglas K; Tezel, Tongalp H

    2016-11-01

    To test define characteristic fundus autofluorescence patterns of different exudative age-related macular degeneration subtypes. Cross-sectional study. Fifty-two patients with choroidal neovascularization because of three different neovascular age-related macular degeneration subtypes were included in the study. Macular and peripheral fundus autofluorescence patterns of study subjects were compared in a masked fashion. Fundus autofluorescence patterns of all three neovascular age-related macular degeneration subtypes revealed similar patterns. However, peripapillary hypo-autofluorescence was more common among patients with polypoidal choroidal vasculopathy (88.2%) compared with patients with retinal angiomatous proliferation (12.5%) and patients without retinal angiomatous proliferation and polypoidal choroidal vasculopathy (21.1%) (P autofluorescence defects in neovascular age-related macular degeneration maybe suggestive of polypoidal choroidal vasculopathy as a variant of neovascular age-related macular degeneration.

  2. Hand-held triangulation laser profilometer with audio output for blind people Profilométre laser à triangulation tenu en main avec sortie sonare pour non-voyants

    Science.gov (United States)

    Farcy, R.; Damaschini, R.

    1998-06-01

    We describe a device currently under industrial development which will give to the blind a means of three-dimensional space perception. It consists of a 350 g hand-held triangulating laser telemeter including electronic parts and batteries, with auditory feedback either inside the apparatus or close to the ear. The microprocessor unit converts in real time the distance measured by the telemeter into a musical note. Scanning the space with an adequate movement of the hand produces musical lines corresponding to the profiles of the environment. We discuss the optical configuration of the system relative to our first year of clinical experimentation.

  3. Case Report of Bullous Pemphigoid following Fundus Fluorescein Angiography

    Directory of Open Access Journals (Sweden)

    Goktug Demirci

    2010-05-01

    Full Text Available Purpose: To report a first case of bullous pemphigoid (BP following intravenous fluorescein for fundus angiography. Clinical Features: A 70-year-old male patient was admitted to the intensive care unit with BP and sepsis. He reported a history of fundus fluorescein angiography with a pre-diagnosis of senile macular degeneration 2 months prior to presentation. At that time, fluorescein extravasated at the antecubital region. Following the procedure, pruritus and erythema began at the wrists bilaterally, and quickly spread to the entire body. The patient also reported a history of allergy to human albumin solution (Plamasteril®; Abbott 15 years before, during bypass surgery. On dermatologic examination, erythematous patches were present on the scalp, chest and anogenital region. Vesicles and bullous lesions were present on upper and lower extremities. On day 2 of hospitalization, tense bullae appeared on the upper and lower extremities. The patient was treated with oral methylprednisolone 48 mg (Prednol®; Mustafa Nevzat, topical clobetasol dipropionate 0.05% cream (Dermovate®; Glaxo SmithKline, and topical 4% urea lotion (Excipial Lipo®; Orva for presumptive bullous pemphigoid. Skin punch biopsy provided tissue for histopathology, direct immunofluorescence examination, and salt extraction, which were all consistent with BP. After 1 month, the patient was transferred to the intensive care unit with sepsis secondary to urinary tract infection; he died 2 weeks later from sepsis and cardiac failure. Conclusions: To our knowledge, this is the first reported case of BP following fundus fluorescein angiography in a patient with known human albumin solution allergy. Consideration should be made to avoid fluorescein angiography, change administration route, or premedicate with antihistamines in patients with known human albumin solution allergy. The association between fundus fluorescein angiography and BP should be further investigated.

  4. Analysis of phakic before intraocular lens implantation for fundus examination

    Directory of Open Access Journals (Sweden)

    Juan Chen

    2014-10-01

    Full Text Available AIM:To investigate the findings of the eyes which were examined preoperatively by three mirror contact lens before the implantation of implantable collamer lens(ICL. To analysis the retinal pathological changes and to explore the clinical analysis of early diagnosis and treatment in retinopathy on fundus examination before operation. METHODS:The retrospective case series study included 127 eyes of 64 patients who underwent phakic intraocular lens implantation were received the fundus examination by three mirror from April 2011 to April 2012 in our hospital. The age, refractive diopter, the findings of Goldmann three mirror examination and the condition of retinal photocoagulation were analysed and concluded.RESULTS: A total of 34 eyes(26.8%out of all 127 eyes(64 caseswere found to have peripheral retinal pathological changes. Eight eyes(6.3%with retinal holes, 15 eyes(11.8%with retinal lattice degeneration, 5 eyes(3.9%with retina cream degeneration, 3 eyes(2.4%with retinal paving stone degeneration,2 eyes with vitreoretinal adhesion and traction,1 eye(0.8%with retinal hemorrhage. Twenty-five cases were given retinal photocoagulation and then received the ICL implantation after 3mo. The follow-up time was 1a. No retinal detachment happened.CONCLUSION:Phakic before intraocular lens implantation for fundus examination by three mirror is contributed to find the peripheral retinal pathological changes and abnormity. And make the appropriate treatment before operation for improving the security of operation, it can also give help to the postoperative follow-up of the fundus of these patients.

  5. Retinal fundus imaging with a plenoptic sensor

    Science.gov (United States)

    Thurin, Brice; Bloch, Edward; Nousias, Sotiris; Ourselin, Sebastien; Keane, Pearse; Bergeles, Christos

    2018-02-01

    Vitreoretinal surgery is moving towards 3D visualization of the surgical field. This require acquisition system capable of recording such 3D information. We propose a proof of concept imaging system based on a light-field camera where an array of micro-lenses is placed in front of a conventional sensor. With a single snapshot, a stack of images focused at different depth are produced on the fly, which provides enhanced depth perception for the surgeon. Difficulty in depth localization of features and frequent focus-change during surgery are making current vitreoretinal heads-up surgical imaging systems cumbersome to use. To improve the depth perception and eliminate the need to manually refocus on the instruments during the surgery, we designed and implemented a proof-of-concept ophthalmoscope equipped with a commercial light-field camera. The sensor of our camera is composed of an array of micro-lenses which are projecting an array of overlapped micro-images. We show that with a single light-field snapshot we can digitally refocus between the retina and a tool located in front of the retina or display an extended depth-of-field image where everything is in focus. The design and system performances of the plenoptic fundus camera are detailed. We will conclude by showing in vivo data recorded with our device.

  6. Fundus autofluorescence applications in retinal imaging

    Science.gov (United States)

    Gabai, Andrea; Veritti, Daniele; Lanzetta, Paolo

    2015-01-01

    Fundus autofluorescence (FAF) is a relatively new imaging technique that can be used to study retinal diseases. It provides information on retinal metabolism and health. Several different pathologies can be detected. Peculiar AF alterations can help the clinician to monitor disease progression and to better understand its pathogenesis. In the present article, we review FAF principles and clinical applications. PMID:26139802

  7. Fundus autofluorescence applications in retinal imaging

    Directory of Open Access Journals (Sweden)

    Andrea Gabai

    2015-01-01

    Full Text Available Fundus autofluorescence (FAF is a relatively new imaging technique that can be used to study retinal diseases. It provides information on retinal metabolism and health. Several different pathologies can be detected. Peculiar AF alterations can help the clinician to monitor disease progression and to better understand its pathogenesis. In the present article, we review FAF principles and clinical applications.

  8. A thresholding based technique to extract retinal blood vessels from fundus images

    Directory of Open Access Journals (Sweden)

    Jyotiprava Dash

    2017-12-01

    Full Text Available Retinal imaging has become the significant tool among all the medical imaging technology, due to its capability to extract many data which is linked to various eye diseases. So, the accurate extraction of blood vessel is necessary that helps the eye care specialists and ophthalmologist to identify the diseases at the early stages. In this paper, we have proposed a computerized technique for extraction of blood vessels from fundus images. The process is conducted in three phases: (i pre-processing where the image is enhanced using contrast limited adaptive histogram equalization and median filter, (ii segmentation using mean-C thresholding to extract retinal blood vessels, (iii post-processing where morphological cleaning operation is used to remove isolated pixels. The performance of the proposed method is tested on and experimental results show that our method achieve an accuracies of 0.955 and 0.954 on Digital retinal images for vessel extraction (DRIVE and Child heart and health study in England (CHASE_DB1 databases respectively.

  9. Ophthalmoscopy versus non-mydriatic fundus photography in the ...

    African Journals Online (AJOL)

    1990-09-01

    Sep 1, 1990 ... non-mydriatic fundus camera in the detection of diabetic retinopathy .... the external and the internal fixation lamps of the non- mydriatic ... .Rosen ES, Raines M, Hancock R. Use of non-mydriatic cameras to screen diabetic ...

  10. What Is the Role of Manual Preference in Hand-Digit Mapping During Finger Counting? A Study in a Large Sample of Right- and Left-Handers.

    Science.gov (United States)

    Zago, Laure; Badets, Arnaud

    2016-01-01

    The goal of the present study was to test whether there is a relationship between manual preference and hand-digit mapping in 369 French adults with similar numbers of right- and left-handers. Manual laterality was evaluated with the finger tapping test to evaluate hand motor asymmetry, and the Edinburgh handedness inventory was used to assess manual preference strength (MPS) and direction. Participants were asked to spontaneously "count on their fingers from 1 to 10" without indications concerning the hand(s) to be used. The results indicated that both MPS and hand motor asymmetry affect the hand-starting preference for counting. Left-handers with a strong left-hand preference (sLH) or left-hand motor asymmetry largely started to count with their left hand (left-starter), while right-handers with a strong right-hand preference (sRH) or right-hand motor asymmetry largely started to count with their right hand (right-starter). Notably, individuals with weak MPS did not show a hand-starting preference. These findings demonstrated that manual laterality contributes to finger counting directionality. Lastly, the results showed a higher proportion of sLH left-starter individuals compared with sRH right-starters, indicating an asymmetric bias of MPS on hand-starting preference. We hypothesize that the higher proportion of sLH left-starters could be explained by the congruence between left-to-right hand-digit mapping and left-to-right mental number line representation that has been largely reported in the literature. Taken together, these results indicate that finger-counting habits integrate biological and cultural information. © The Author(s) 2015.

  11. A review of fundus autofluorescence imaging

    OpenAIRE

    D. J. Booysen

    2013-01-01

    Autofluorscence photography of the retina provides important diagnostic information about diseases that affect the outer retina; more specifically the retinal pigment epithelium and photoreceptors. Fundus autofluorescence can alsobe used to evaluate macular pigment density and other diseases of the retina and choroid. It is a non-invasive clinical tool which has the potential to revolutionise clinical retina practice. (S Afr Optom 2013 72(1) 46-53)

  12. Computer-aided diagnosis based on enhancement of degraded fundus photographs.

    Science.gov (United States)

    Jin, Kai; Zhou, Mei; Wang, Shaoze; Lou, Lixia; Xu, Yufeng; Ye, Juan; Qian, Dahong

    2018-05-01

    Retinal imaging is an important and effective tool for detecting retinal diseases. However, degraded images caused by the aberrations of the eye can disguise lesions, so that a diseased eye can be mistakenly diagnosed as normal. In this work, we propose a new image enhancement method to improve the quality of degraded images. A new method is used to enhance degraded-quality fundus images. In this method, the image is converted from the input RGB colour space to LAB colour space and then each normalized component is enhanced using contrast-limited adaptive histogram equalization. Human visual system (HVS)-based fundus image quality assessment, combined with diagnosis by experts, is used to evaluate the enhancement. The study included 191 degraded-quality fundus photographs of 143 subjects with optic media opacity. Objective quality assessment of image enhancement (range: 0-1) indicated that our method improved colour retinal image quality from an average of 0.0773 (variance 0.0801) to an average of 0.3973 (variance 0.0756). Following enhancement, area under curves (AUC) were 0.996 for the glaucoma classifier, 0.989 for the diabetic retinopathy (DR) classifier, 0.975 for the age-related macular degeneration (AMD) classifier and 0.979 for the other retinal diseases classifier. The relatively simple method for enhancing degraded-quality fundus images achieves superior image enhancement, as demonstrated in a qualitative HVS-based image quality assessment. This retinal image enhancement may, therefore, be employed to assist ophthalmologists in more efficient screening of retinal diseases and the development of computer-aided diagnosis. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  13. Assessment of Laparoscopic Skills Performance: 2D Versus 3D Vision and Classic Instrument Versus New Hand-Held Robotic Device for Laparoscopy.

    Science.gov (United States)

    Leite, Mariana; Carvalho, Ana F; Costa, Patrício; Pereira, Ricardo; Moreira, Antonio; Rodrigues, Nuno; Laureano, Sara; Correia-Pinto, Jorge; Vilaça, João L; Leão, Pedro

    2016-02-01

    Laparoscopic surgery has undeniable advantages, such as reduced postoperative pain, smaller incisions, and faster recovery. However, to improve surgeons' performance, ergonomic adaptations of the laparoscopic instruments and introduction of robotic technology are needed. The aim of this study was to ascertain the influence of a new hand-held robotic device for laparoscopy (HHRDL) and 3D vision on laparoscopic skills performance of 2 different groups, naïve and expert. Each participant performed 3 laparoscopic tasks-Peg transfer, Wire chaser, Knot-in 4 different ways. With random sequencing we assigned the execution order of the tasks based on the first type of visualization and laparoscopic instrument. Time to complete each laparoscopic task was recorded and analyzed with one-way analysis of variance. Eleven experts and 15 naïve participants were included. Three-dimensional video helps the naïve group to get better performance in Peg transfer, Wire chaser 2 hands, and Knot; the new device improved the execution of all laparoscopic tasks (P < .05). For expert group, the 3D video system benefited them in Peg transfer and Wire chaser 1 hand, and the robotic device in Peg transfer, Wire chaser 1 hand, and Wire chaser 2 hands (P < .05). The HHRDL helps the execution of difficult laparoscopic tasks, such as Knot, in the naïve group. Three-dimensional vision makes the laparoscopic performance of the participants without laparoscopic experience easier, unlike those with experience in laparoscopic procedures. © The Author(s) 2015.

  14. Human Digital Modeling & Hand Scanning Lab

    Data.gov (United States)

    Federal Laboratory Consortium — This laboratory incorporates specialized scanning equipment, computer workstations and software applications for the acquisition and analysis of digitized models of...

  15. Automated Detection of Glaucoma From Topographic Features of the Optic Nerve Head in Color Fundus Photographs.

    Science.gov (United States)

    Chakrabarty, Lipi; Joshi, Gopal Datt; Chakravarty, Arunava; Raman, Ganesh V; Krishnadas, S R; Sivaswamy, Jayanthi

    2016-07-01

    To describe and evaluate the performance of an automated CAD system for detection of glaucoma from color fundus photographs. Color fundus photographs of 2252 eyes from 1126 subjects were collected from 2 centers: Aravind Eye Hospital, Madurai and Coimbatore, India. The images of 1926 eyes (963 subjects) were used to train an automated image analysis-based system, which was developed to provide a decision on a given fundus image. A total of 163 subjects were clinically examined by 2 ophthalmologists independently and their diagnostic decisions were recorded. The consensus decision was defined to be the clinical reference (gold standard). Fundus images of eyes with disagreement in diagnosis were excluded from the study. The fundus images of the remaining 314 eyes (157 subjects) were presented to 4 graders and their diagnostic decisions on the same were collected. The performance of the system was evaluated on the 314 images, using the reference standard. The sensitivity and specificity of the system and 4 independent graders were determined against the clinical reference standard. The system achieved an area under receiver operating characteristic curve of 0.792 with a sensitivity of 0.716 and specificity of 0.717 at a selected threshold for the detection of glaucoma. The agreement with the clinical reference standard as determined by Cohen κ is 0.45 for the proposed system. This is comparable to that of the image-based decisions of 4 ophthalmologists. An automated system was presented for glaucoma detection from color fundus photographs. The overall evaluation results indicated that the presented system was comparable in performance to glaucoma classification by a manual grader solely based on fundus image examination.

  16. Telemedicine for diabetic retinopathy screening using an ultra-widefield fundus camera

    Directory of Open Access Journals (Sweden)

    Hussain N

    2017-08-01

    Full Text Available Nazimul Hussain,1 Maryam Edraki,2 Rima Tahhan,2 Nishanth Sanalkumar,2 Sami Kenz,2 Nagwa Khalil Akasha,2 Brian Mtemererwa,2 Nahed Mohammed2 1Department of Ophthalmology, Al Zahra Hospital, Sharjah, United Arab Emirates; 2Department of Endocrinology, Al Zahra Hospital, Sharjah, United Arab Emirates Objective: Telemedicine reporting of diabetic retinopathy (DR screening using ultra-widefield (UWF fundus camera. Materials and methods: Cross-sectional study of diabetic patients who visited the endocrinology department of a private multi-specialty hospital in United Arab Emirates between April 2015 and January 2017 who underwent UWF fundus imaging. Fundus pictures are then accessed at the Retina Clinic in the Department of Ophthalmology. Primary outcome measure was incidence of any form of DR detected. The secondary outcome measure was failure to take good image and inability to grade. Results: A total of 1,024 diabetic individuals were screened for DR from April 2015 to January 2017 in the department of Endocrinology. Rate of DR was 9.27%; 165 eyes of 95 individuals were diagnosed to have some form of DR. Mild non-proliferative DR (NPDR was seen in 114 of 165 eyes (69.09%, moderate NPDR in 32 eyes (19.39%, severe NPDR in six eyes (3.64%, and proliferative DR (PDR in 13 eyes (7.88%. The secondary outcome measure of poor image acquisition was seen in one individual who had an image acquired in one eye that could not be graded due to bad picture quality. Conclusions: The present study has shown the effectiveness of DR screening using UWF fundus camera. It has shown the effectiveness of trained nursing personnel taking fundus images. This model can be replicated in any private multi-specialty hospital and reduce the burden of DR screening in the retina clinic and enhance early detection of treatable DR. Keywords: telemedicine, ultra-widefield camera, diabetic retinopathy screening

  17. Hand-Held Photometer for Instant On-Spot Quantification of Nucleic Acids, Proteins, and Cells.

    Science.gov (United States)

    Li, Shi-Hao; Jain, Abhinav; Tscharntke, Timo; Arnold, Tobias; Trau, Dieter W

    2018-02-20

    This paper presents a novel hand-held photometer, termed "Photopette", for on-spot absorbance measurements of biochemical analytes. The Photopette is a multicomponent, highly portable device with an overall weight of 160 g, which fits within 202 mm × 47 mm × 42 mm. Designed in the form factor of a micropipette, Photopette integrates a photodiode detector with light emitting diodes (LEDs) to form a highly customizable photometer which supports a wide variety of applications within the wavelengths between 260 and 1050 nm. A dual-purpose disposable reflective tip was designed to act as a sample holder and a light-reflecting system, which is in stark contrast to the operation of mainstream spectrophotometers and photometers. Small volume analytes may be measured with low sample loss using this proprietary CuveTip. A user-friendly software application running on smart devices was developed to control and read the values from Photopette via a low-energy Bluetooth link. This one-step strategy allows measurements on-spot without sample transfer, minimizing cross-contamination and human error. The results reported in this paper demonstrate Photopette's great potential to quantify DNA, direct protein, and cell density directly within the laminar flow hood. Results are compared with a Nanodrop 2000c spectrophotometer, a mainstream spectrophotometer for small-volume measurements.

  18. [Cinematography of ocular fundus with a jointed optical system and tv or cine-camera (author's transl)].

    Science.gov (United States)

    Kampik, A; Rapp, J

    1979-02-01

    A method of Cinematography of the ocular fundus is introduced which--by connecting a camera with an indirect ophthalmoscop--allows to record the monocular picture of the fundus as produced by the ophthalmic lens.

  19. DrishtiCare: a telescreening platform for diabetic retinopathy powered with fundus image analysis.

    Science.gov (United States)

    Joshi, Gopal Datt; Sivaswamy, Jayanthi

    2011-01-01

    Diabetic retinopathy is the leading cause of blindness in urban populations. Early diagnosis through regular screening and timely treatment has been shown to prevent visual loss and blindness. It is very difficult to cater to this vast set of diabetes patients, primarily because of high costs in reaching out to patients and a scarcity of skilled personnel. Telescreening offers a cost-effective solution to reach out to patients but is still inadequate due to an insufficient number of experts who serve the diabetes population. Developments toward fundus image analysis have shown promise in addressing the scarcity of skilled personnel for large-scale screening. This article aims at addressing the underlying issues in traditional telescreening to develop a solution that leverages the developments carried out in fundus image analysis. We propose a novel Web-based telescreening solution (called DrishtiCare) integrating various value-added fundus image analysis components. A Web-based platform on the software as a service (SaaS) delivery model is chosen to make the service cost-effective, easy to use, and scalable. A server-based prescreening system is employed to scrutinize the fundus images of patients and to refer them to the experts. An automatic quality assessment module ensures transfer of fundus images that meet grading standards. An easy-to-use interface, enabled with new visualization features, is designed for case examination by experts. Three local primary eye hospitals have participated and used DrishtiCare's telescreening service. A preliminary evaluation of the proposed platform is performed on a set of 119 patients, of which 23% are identified with the sight-threatening retinopathy. Currently, evaluation at a larger scale is under process, and a total of 450 patients have been enrolled. The proposed approach provides an innovative way of integrating automated fundus image analysis in the telescreening framework to address well-known challenges in large

  20. Applying and extending ISO/TC42 digital camera resolution standards to mobile imaging products

    Science.gov (United States)

    Williams, Don; Burns, Peter D.

    2007-01-01

    There are no fundamental differences between today's mobile telephone cameras and consumer digital still cameras that suggest many existing ISO imaging performance standards do not apply. To the extent that they have lenses, color filter arrays, detectors, apertures, image processing, and are hand held, there really are no operational or architectural differences. Despite this, there are currently differences in the levels of imaging performance. These are driven by physical and economic constraints, and image-capture conditions. Several ISO standards for resolution, well established for digital consumer digital cameras, require care when applied to the current generation of cell phone cameras. In particular, accommodation of optical flare, shading non-uniformity and distortion are recommended. We offer proposals for the application of existing ISO imaging resolution performance standards to mobile imaging products, and suggestions for extending performance standards to the characteristic behavior of camera phones.

  1. A review of fundus autofluorescence imaging

    Directory of Open Access Journals (Sweden)

    D. J. Booysen

    2013-12-01

    Full Text Available Autofluorscence photography of the retina provides important diagnostic information about diseases that affect the outer retina; more specifically the retinal pigment epithelium and photoreceptors. Fundus autofluorescence can alsobe used to evaluate macular pigment density and other diseases of the retina and choroid. It is a non-invasive clinical tool which has the potential to revolutionise clinical retina practice. (S Afr Optom 2013 72(1 46-53

  2. 3D indoor modeling using a hand-held embedded system with multiple laser range scanners

    Science.gov (United States)

    Hu, Shaoxing; Wang, Duhu; Xu, Shike

    2016-10-01

    Accurate three-dimensional perception is a key technology for many engineering applications, including mobile mapping, obstacle detection and virtual reality. In this article, we present a hand-held embedded system designed for constructing 3D representation of structured indoor environments. Different from traditional vehicle-borne mobile mapping methods, the system presented here is capable of efficiently acquiring 3D data while an operator carrying the device traverses through the site. It consists of a simultaneous localization and mapping(SLAM) module, a 3D attitude estimate module and a point cloud processing module. The SLAM is based on a scan matching approach using a modern LIDAR system, and the 3D attitude estimate is generated by a navigation filter using inertial sensors. The hardware comprises three 2D time-flight laser range finders and an inertial measurement unit(IMU). All the sensors are rigidly mounted on a body frame. The algorithms are developed on the frame of robot operating system(ROS). The 3D model is constructed using the point cloud library(PCL). Multiple datasets have shown robust performance of the presented system in indoor scenarios.

  3. Correlation between Spectral Optical Coherence Tomography and Fundus Autofluorescence at the margins of Geographic Atrophy

    Science.gov (United States)

    Brar, Manpreet; Kozak, Igor; Cheng, Lingyun; Bartsch, Dirk-Uwe G.; Yuson, Ritchie; Nigam, Nitin; Oster, Stephen F.; Mojana, Francesca; Freeman, William R.

    2009-01-01

    Purpose We studied the appearance of margins of Geographic atrophy in high- resolution optical coherence tomography (OCT) images and correlate those changes with fundus autofluorescence imaging. Design Retrospective observational case study. Methods Patients with geographic atrophy secondary to dry age related macular degeneration (ARMD) were assessed by means of Spectral Domain OCT (Spectralis HRA/OCT; Heidelberg Engineering, Heidelberg, Germany or OTI, Inc, Toronto, Canada) as well as Autofluoresence Imaging (HRA or Spectralis Heidelberg Engineering, Heidelberg, Germany): The outer retinal layer alterations were analyzed in the junctional zone between normal retina and atrophic retina, and correlated with corresponding fundus autofluorescence. Results 23 eyes of 16 patients aged between 62 years to 96 years were examined. There was a significant association between OCT findings and the fundus autofluorescence findings(r=0.67, pautofluorescence; Smooth margins on OCT correspond significantly to normal fundus autofluorescence. (Kappa-0.7348, pautofluorescence; secondary to increased lipofuscin may together serve as determinants of progression of geographic atrophy. PMID:19541290

  4. Automated detection and differentiation of drusen, exudates, and cotton-wool spots in digital color fundus photographs for diabetic retinopathy diagnosis.

    Science.gov (United States)

    Niemeijer, Meindert; van Ginneken, Bram; Russell, Stephen R; Suttorp-Schulten, Maria S A; Abràmoff, Michael D

    2007-05-01

    To describe and evaluate a machine learning-based, automated system to detect exudates and cotton-wool spots in digital color fundus photographs and differentiate them from drusen, for early diagnosis of diabetic retinopathy. Three hundred retinal images from one eye of 300 patients with diabetes were selected from a diabetic retinopathy telediagnosis database (nonmydriatic camera, two-field photography): 100 with previously diagnosed bright lesions and 200 without. A machine learning computer program was developed that can identify and differentiate among drusen, (hard) exudates, and cotton-wool spots. A human expert standard for the 300 images was obtained by consensus annotation by two retinal specialists. Sensitivities and specificities of the annotations on the 300 images by the automated system and a third retinal specialist were determined. The system achieved an area under the receiver operating characteristic (ROC) curve of 0.95 and sensitivity/specificity pairs of 0.95/0.88 for the detection of bright lesions of any type, and 0.95/0.86, 0.70/0.93, and 0.77/0.88 for the detection of exudates, cotton-wool spots, and drusen, respectively. The third retinal specialist achieved pairs of 0.95/0.74 for bright lesions and 0.90/0.98, 0.87/0.98, and 0.92/0.79 per lesion type. A machine learning-based, automated system capable of detecting exudates and cotton-wool spots and differentiating them from drusen in color images obtained in community based diabetic patients has been developed and approaches the performance level of retinal experts. If the machine learning can be improved with additional training data sets, it may be useful for detecting clinically important bright lesions, enhancing early diagnosis, and reducing visual loss in patients with diabetes.

  5. Fundus autofluorescence and optical coherence tomography of congenital grouped albinotic spots.

    Science.gov (United States)

    Kim, David Y; Hwang, John C; Moore, Anthony T; Bird, Alan C; Tsang, Stephen H

    2010-09-01

    The purpose of this study was to describe the findings of fundus autofluores-cence (FAF) and optical coherence tomography in a series of patients with congenital grouped albinotic spots. Three eyes of three patients with congenital grouped albinotic spots were evaluated with FAF and optical coherence tomography imaging to evaluate the nature of the albinotic spots. In all three eyes with congenital grouped albinotic spots, FAF imaging showed autofluorescent spots corresponding to the albinotic spots seen on stereo biomicroscopy. One eye also had additional spots detected on FAF imaging that were not visible on stereo biomicroscopy or color fundus photographs. Fundus autofluorescence imaging of the spots showed decreased general autofluorescence and decreased peripheral autofluorescence surrounding central areas of retained or increased autofluorescence. Optical coherence tomography showed a disruption in signal from the hyperreflective layer corresponding to the inner and outer segment junction and increased signal backscattering from the choroid in the area of the spots. Fluorescein angiography showed early and stable hyperfluorescence of the spots without leakage. In this case series, FAF showed decreased autofluorescence of the spots consistent with focal retinal pigment epithelium atrophy or abnormal material blocking normal autofluorescence and areas of increased autofluorescence suggesting retinal pigment epithelium dysfunction. The findings of optical coherence tomography and fluorescein angiography suggest photoreceptor and retinal pigment epithelium layer abnormalities. Fundus autofluorescence and optical coherence tomography are useful noninvasive diagnostic adjuncts that can aid in the diagnosis of congenital grouped albinotic spots, help determine extent of disease, and contribute to our understanding of its pathophysiology.

  6. Centrifugal expansion of fundus autofluorescence patterns in Stargardt disease over time.

    Science.gov (United States)

    Cukras, Catherine A; Wong, Wai T; Caruso, Rafael; Cunningham, Denise; Zein, Wadih; Sieving, Paul A

    2012-02-01

    To study the longitudinal changes in autofluorescence in Stargardt disease to reveal aspects of disease progression not previously evident. Changes in autofluorescence reflect changing fluorophore compositions of lipofuscin and melanin in retinal pigment epithelial cells, which has been hypothesized to contribute to Stargardt disease pathogenesis. We examined the temporospatial patterns of fundus autofluorescence with excitation at both 488 nm (standard fundus autofluorescence) and 795 nm (near-infrared autofluorescence) in a longitudinal case series involving 8 eyes of 4 patients (range of follow-up, 11-57 months; mean, 39 months). Image processing was performed to analyze spatial and temporal cross-modality associations. Longitudinal fundus autofluorescence imaging of fleck lesions revealed hyperautofluorescent lesions that extended in a centrifugal direction from the fovea with time. Patterns of spread were nonrandom and followed a radial path that left behind a trail of diminishing autofluorescence. Longitudinal near-infrared autofluorescence imaging also demonstrated centrifugal lesion spread but with fewer hyperautofluorescent lesions, suggestive of more transient hyperautofluorescence and more rapid decay at longer wavelengths. Fundus autofluorescence and near-infrared autofluorescence abnormalities were spatially correlated with each other, and together they reflect systematic progressions in fleck distribution and fluorophore composition occurring during the natural history of the disease. Stargardt disease fleck lesions do not evolve randomly in location but instead follow consistent patterns of radial expansion and a systematic decay of autofluorescence that reflect changing lipofuscin and melanin compositions in retinal pigment epithelial cells. These progressive foveal-to-peripheral changes are helpful in elucidating molecular and cellular mechanisms underlying Stargardt disease and may constitute potential outcome measures in clinical trials.

  7. Opinion and Special Articles: Amateur fundus photography with various new devices: Our experience as neurology residents.

    Science.gov (United States)

    Zafar, Saman; Cardenas, Ylec Mariana; Leishangthem, Lakshmi; Yaddanapudi, Sridhara

    2018-05-08

    Times are changing in the way we secure and share patient fundus photographs to enhance our diagnostic skills in neurology. At the recent American Academy of Neurology meeting, the use of a fundus camera and smartphones to secure good-quality fundus photographs of patients presenting with headache to the emergency department (ED) was presented. We were enthusiastic to replicate the success of the Fundus Photography vs Ophthalmoscopy Trial Outcomes in the Emergency Department (FOTO-ED) study in our neurology department, but encountered problems in terms of cost, setup, feasibility, and portability of the device. As neurology residents, we came up with 3 easier options. We present these 3 options as our personal experience, and hope to reignite enthusiasm among neurology trainees to find their own means of performing ophthalmoscopy routinely in the hospital, as it appears that the Internet market is now thriving with many other devices to make this examination easier and more rewarding. Of the options explored above, the Handheld Fundus Camera was a clear favorite among the residents, and we have placed one in our call room for routine use. It travels to the clinic, floor, intensive care unit, and ED when needed. It has enhanced the way we approach the fundus examination and been a fun skill to acquire. We look forward to further advances that will make it possible to carry such a device in a physician's pocket. © 2018 American Academy of Neurology.

  8. Mechanism of resveratrol-induced relaxation of the guinea pig fundus.

    Science.gov (United States)

    Tsai, Ching-Chung; Tey, Shu-Leei; Lee, Ming-Che; Liu, Ching-Wen; Su, Yu-Tsun; Huang, Shih-Che

    2018-04-01

    Resveratrol is a polyphenolic compound that can be isolated from plants and also is a constituent of red wine. Resveratrol induces relaxation of vascular smooth muscle and may prevent cardiovascular diseases. Impaired gastric accommodation plays an important role in functional dyspepsia and fundic relaxation and is a therapeutic target of functional dyspepsia. Although drugs for fundic relaxation have been developed, these types of drugs are still rare. The purpose of this study was to investigate the relaxant effects of resveratrol in the guinea pig fundus. We studied the relaxant effects of resveratrol in the guinea pig fundus. In addition, we investigated the mechanism of resveratrol-induced relaxation on the guinea pig fundus by using tetraethylammonium (a non-selective potassium channel blocker), apamine (a selective inhibitor of the small conductance calcium-activated potassium channel), iberiotoxin (an inhibitor of large conductance calcium-activated potassium channels), glibenclamide (an ATP-sensitive potassium channel blocker), KT 5720 (a cAMP-dependent protein kinase A inhibitor), KT 5823 (a cGMP-dependent protein kinase G inhibitor), NG-nitro-L-arginine (a competitive inhibitor of nitric oxide synthase), tetrodotoxin (a selective neuronal Na + channel blocker), ω-conotoxin GVIA (a selective neuronal Ca 2+ channel blocker) and G-15 (a G-protein coupled estrogen receptor antagonist). The results of this study showed that resveratrol has potent and dose-dependent relaxant effects on the guinea pig fundic muscle. In addition, the results showed that resveratrol-induced relaxation of the guinea pig fundus occurs through nitric oxide and ATP-sensitive potassium channels. This study provides the first evidence concerning the relaxant effects of resveratrol in the guinea pig fundic muscle strips. Furthermore, resveratrol may be a potential drug to relieve gastrointestinal dyspepsia. Copyright © 2018 Elsevier GmbH. All rights reserved.

  9. Suitability of capillary blood obtained by a minimally invasive lancet technique to detect subclinical ketosis in dairy cows by using 3 different electronic hand-held devices.

    Science.gov (United States)

    Kanz, P; Drillich, M; Klein-Jöbstl, D; Mair, B; Borchardt, S; Meyer, L; Schwendenwein, I; Iwersen, M

    2015-09-01

    The objective of this study was to evaluate the suitability of capillary blood obtained by a minimally invasive lancet technique to detect subclinical ketosis in 49 prepartum and 191 postpartum Holstein-Friesian cows using 3 different electronic hand-held devices [FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini), NovaVet (NOV, Nova Biomedical)]. The β-hydroxybutyrate (BHBA) concentration in serum harvested from coccygeal blood samples was analyzed in a laboratory and used as a reference value. Capillary samples were obtained from the skin of the exterior vulva by using 1 of 3 different lancets. In all samples, the concentration of BHBA was immediately analyzed with all 3 hand-held devices used in random order. All lancets used in the study were eligible for capillary blood collection but differed in the total number of incisions needed. Spearman correlation coefficients between the BHBA concentrations in capillary blood and the reference test were highly significant with 83% for the FSP, 73% for the NOV, and 63% for the GLX. Using capillary blood, the FSP overestimated the mean BHBA concentration compared with the reference test (+0.08 mmol/L), whereas the GLX and NOV underestimated the mean concentration (-0.07 and -0.01 mmol/L). When a BHBA concentration of 1.2 mmol/L in serum was used to define subclinical ketosis, the corresponding analyses of receiver operating characteristics resulted in optimized thresholds for capillary blood of 1.1 mmol/L for the NOV and GLX devices, and of 1.0 mmol/L for the FSP. Based on these thresholds, sensitivities (Se) and specificities (Sp) were 89 and 84% for the NOV, 80 and 89% for the GLX, and 100 and 76% for the FSP. Based on a serum BHBA concentration of 1.4 mmol/L, analyses of receiver operating characteristics resulted in optimized cut-offs of 1.4 mmol/L for the FSP (Se 100%, Sp 92%), 1.3 mmol/L for the NOV (Se 80%, Sp 95%), and 1.1 mmol/L (Se 90%, Sp 85%) for the GLX. Using these optimized thresholds

  10. Accuracy of ultra-wide-field fundus ophthalmoscopy-assisted deep learning, a machine-learning technology, for detecting age-related macular degeneration.

    Science.gov (United States)

    Matsuba, Shinji; Tabuchi, Hitoshi; Ohsugi, Hideharu; Enno, Hiroki; Ishitobi, Naofumi; Masumoto, Hiroki; Kiuchi, Yoshiaki

    2018-05-09

    To predict exudative age-related macular degeneration (AMD), we combined a deep convolutional neural network (DCNN), a machine-learning algorithm, with Optos, an ultra-wide-field fundus imaging system. First, to evaluate the diagnostic accuracy of DCNN, 364 photographic images (AMD: 137) were amplified and the area under the curve (AUC), sensitivity and specificity were examined. Furthermore, in order to compare the diagnostic abilities between DCNN and six ophthalmologists, we prepared yield 84 sheets comprising 50% of normal and wet-AMD data each, and calculated the correct answer rate, specificity, sensitivity, and response times. DCNN exhibited 100% sensitivity and 97.31% specificity for wet-AMD images, with an average AUC of 99.76%. Moreover, comparing the diagnostic abilities of DCNN versus six ophthalmologists, the average accuracy of the DCNN was 100%. On the other hand, the accuracy of ophthalmologists, determined only by Optos images without a fundus examination, was 81.9%. A combination of DCNN with Optos images is not better than a medical examination; however, it can identify exudative AMD with a high level of accuracy. Our system is considered useful for screening and telemedicine.

  11. Fundus autofluorescence and optical coherence tomography findings in thiamine responsive megaloblastic anemia.

    Science.gov (United States)

    Ach, Thomas; Kardorff, Rüdiger; Rohrschneider, Klaus

    2015-01-01

    To report ophthalmologic fundus autofluorescence and spectral domain optical coherence tomography findings in a patient with thiamine responsive megaloblastic anemia (TRMA). A 13-year-old girl with genetically proven TRMA was ophthalmologically (visual acuity, funduscopy, perimetry, electroretinogram) followed up over >5 years. Fundus imaging also included autofluorescence and spectral domain optical coherence tomography. During a 5-year follow-up, visual acuity and visual field decreased, despite a special TRMA diet. Funduscopy revealed bull's eye appearance, whereas fundus autofluorescence showed central and peripheral hyperfluorescence and perifoveal hypofluorescence. Spectral domain optical coherence tomography revealed affected inner segment ellipsoid band and irregularities in the retinal pigment epithelium and choroidea. Autofluorescence and spectral domain optical coherence tomography findings in a patient with TRMA show retinitis pigmentosa-like retina, retinal pigment epithelium, and choroid alterations. These findings might progress even under special TRMA diet, indispensable to life. Ophthalmologist should consider TRMA in patients with deafness and ophthalmologic disorders.

  12. Multi-frame super-resolution with quality self-assessment for retinal fundus videos.

    Science.gov (United States)

    Köhler, Thomas; Brost, Alexander; Mogalle, Katja; Zhang, Qianyi; Köhler, Christiane; Michelson, Georg; Hornegger, Joachim; Tornow, Ralf P

    2014-01-01

    This paper proposes a novel super-resolution framework to reconstruct high-resolution fundus images from multiple low-resolution video frames in retinal fundus imaging. Natural eye movements during an examination are used as a cue for super-resolution in a robust maximum a-posteriori scheme. In order to compensate heterogeneous illumination on the fundus, we integrate retrospective illumination correction for photometric registration to the underlying imaging model. Our method utilizes quality self-assessment to provide objective quality scores for reconstructed images as well as to select regularization parameters automatically. In our evaluation on real data acquired from six human subjects with a low-cost video camera, the proposed method achieved considerable enhancements of low-resolution frames and improved noise and sharpness characteristics by 74%. In terms of image analysis, we demonstrate the importance of our method for the improvement of automatic blood vessel segmentation as an example application, where the sensitivity was increased by 13% using super-resolution reconstruction.

  13. In-Season Yield Prediction of Cabbage with a Hand-Held Active Canopy Sensor.

    Science.gov (United States)

    Ji, Rongting; Min, Ju; Wang, Yuan; Cheng, Hu; Zhang, Hailin; Shi, Weiming

    2017-10-08

    Efficient and precise yield prediction is critical to optimize cabbage yields and guide fertilizer application. A two-year field experiment was conducted to establish a yield prediction model for cabbage by using the Greenseeker hand-held optical sensor. Two cabbage cultivars (Jianbao and Pingbao) were used and Jianbao cultivar was grown for 2 consecutive seasons but Pingbao was only grown in the second season. Four chemical nitrogen application rates were implemented: 0, 80, 140, and 200 kg·N·ha -1 . Normalized difference vegetation index (NDVI) was collected 20, 50, 70, 80, 90, 100, 110, 120, 130, and 140 days after transplanting (DAT). Pearson correlation analysis and regression analysis were performed to identify the relationship between the NDVI measurements and harvested yields of cabbage. NDVI measurements obtained at 110 DAT were significantly correlated to yield and explained 87-89% and 75-82% of the cabbage yield variation of Jianbao cultivar over the two-year experiment and 77-81% of the yield variability of Pingbao cultivar. Adjusting the yield prediction models with CGDD (cumulative growing degree days) could make remarkable improvement to the accuracy of the prediction model and increase the determination coefficient to 0.82, while the modification with DFP (days from transplanting when GDD > 0) values did not. The integrated exponential yield prediction equation was better than linear or quadratic functions and could accurately make in-season estimation of cabbage yields with different cultivars between years.

  14. Hand-arm vibration disorder among grass-cutter workers in Malaysia.

    Science.gov (United States)

    Azmir, Nor Azali; Ghazali, Mohd Imran; Yahya, Musli Nizam; Ali, Mohamad Hanafi

    2016-09-01

    Prolonged exposure to hand-transmitted vibration from grass-cutting machines has been associated with increasing occurrences of symptoms and signs of occupational diseases related to hand-arm vibration syndrome (HAVS). A cross-sectional study was carried out using an adopted HAVS questionnaire on hand-arm vibration exposure and symptoms distributed to 168 male workers from the grass and turf maintenance industry who use hand-held grass-cutting machines as part of their work. The prevalence ratio and symptom correlation to HAVS between high and low-moderate exposure risk groups were evaluated. There were positive HAVS symptoms relationships between the low-moderate exposure group and the high exposure group among hand-held grass-cutting workers. The prevalence ratio was considered high because there were indicators that fingers turned white and felt numb, 3.63, 95% CI [1.41, 9.39] and 4.24, 95% CI [2.18, 8.27], respectively. Less than 14.3% of workers stated that they were aware of the occupational hand-arm vibration, and it seemed to be related to the finger blanching and numbness. The results suggest that HAVS is under-diagnosed in Malaysia, especially in the agricultural sectors. More information related to safety and health awareness programmes for HAVS exposure is required among hand-held grass-cutting workers.

  15. Supervised retinal vessel segmentation from color fundus images based on matched filtering and AdaBoost classifier.

    Directory of Open Access Journals (Sweden)

    Nogol Memari

    Full Text Available The structure and appearance of the blood vessel network in retinal fundus images is an essential part of diagnosing various problems associated with the eyes, such as diabetes and hypertension. In this paper, an automatic retinal vessel segmentation method utilizing matched filter techniques coupled with an AdaBoost classifier is proposed. The fundus image is enhanced using morphological operations, the contrast is increased using contrast limited adaptive histogram equalization (CLAHE method and the inhomogeneity is corrected using Retinex approach. Then, the blood vessels are enhanced using a combination of B-COSFIRE and Frangi matched filters. From this preprocessed image, different statistical features are computed on a pixel-wise basis and used in an AdaBoost classifier to extract the blood vessel network inside the image. Finally, the segmented images are postprocessed to remove the misclassified pixels and regions. The proposed method was validated using publicly accessible Digital Retinal Images for Vessel Extraction (DRIVE, Structured Analysis of the Retina (STARE and Child Heart and Health Study in England (CHASE_DB1 datasets commonly used for determining the accuracy of retinal vessel segmentation methods. The accuracy of the proposed segmentation method was comparable to other state of the art methods while being very close to the manual segmentation provided by the second human observer with an average accuracy of 0.972, 0.951 and 0.948 in DRIVE, STARE and CHASE_DB1 datasets, respectively.

  16. Fundus autofluorescence and optical coherence tomographic findings in acute zonal occult outer retinopathy.

    Science.gov (United States)

    Fujiwara, Takamitsu; Imamura, Yutaka; Giovinazzo, Vincent J; Spaide, Richard F

    2010-09-01

    The purpose of this study was to investigate the fundus autofluorescence and optical coherence tomography findings in eyes with acute zonal occult outer retinopathy (AZOOR). A retrospective observational case series of the fundus autofluorescence and spectral domain optical coherence tomography in a series of patients with AZOOR. There were 19 eyes of 11 patients (10 women), who had a mean age of 49.1 +/- 13.9 years. Fundus autofluorescence abnormalities were seen in 17 of the 19 eyes, were more common in the peripapillary area, and were smaller in extent than the optical coherence tomography abnormalities. Nine eyes showed progression of hypoautofluorescence area during the mean follow-up of 69.7 months. The mean thickness of the photoreceptor layer at fovea was 177 microm in eyes with AZOOR, which was significantly thinner than controls (193 microm, P = 0.049). Abnormal retinal laminations were found in 12 eyes and were located over areas of loss of the photoreceptors. The subfoveal choroidal thickness was 243 microm, which is normal. Fundus autofluorescence abnormalities in AZOOR showed distinct patterns of retinal pigment epithelial involvement, which may be progressive. Thinning of photoreceptor cell layer with loss of the outer segments and abnormal inner retinal lamination in the context of a normal choroid are commonly found in AZOOR.

  17. Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study

    Science.gov (United States)

    Perraton, Luke G.; Bower, Kelly J.; Adair, Brooke; Pua, Yong-Hao; Williams, Gavin P.; McGaw, Rebekah

    2015-01-01

    Introduction Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to examine the reliability of different algorithms for RFD calculation and to examine the intra-rater, inter-rater, and inter-device reliability of HHD as well as the concurrent validity of HHD for the assessment of isometric lower limb muscle strength and power. Methods 30 healthy young adults (age: 23±5yrs, male: 15) were assessed on two sessions. Isometric muscle strength and power were measured using peak force and RFD respectively using two HHDs (Lafayette Model-01165 and Hoggan microFET2) and a criterion-reference KinCom dynamometer. Statistical analysis of reliability and validity comprised intraclass correlation coefficients (ICC), Pearson correlations, concordance correlations, standard error of measurement, and minimal detectable change. Results Comparison of RFD methods revealed that a peak 200ms moving window algorithm provided optimal reliability results. Intra-rater, inter-rater, and inter-device reliability analysis of peak force and RFD revealed mostly good to excellent reliability (coefficients ≥ 0.70) for all muscle groups. Concurrent validity analysis showed moderate to excellent relationships between HHD and fixed dynamometry for the hip and knee (ICCs ≥ 0.70) for both peak force and RFD, with mostly poor to good results shown for the ankle muscles (ICCs = 0.31–0.79). Conclusions Hand-held dynamometry has good to excellent reliability and validity for most measures of isometric lower limb strength and power in a healthy population, particularly for proximal muscle groups. To aid implementation we have created freely available software to extract these variables from data stored on the Lafayette device. Future research should examine the reliability

  18. An embedded system developed for hand held assay used in water monitoring

    Science.gov (United States)

    Wu, Lin; Wang, Jianwei; Ramakrishna, Bharath; Hsueh, Mingkai; Liu, Jonathan; Wu, Qufei; Wu, Chao-Cheng; Cao, Mang; Chang, Chein-I.; Jensen, Janet L.; Jensen, James O.; Knapp, Harlan; Daniel, Robert; Yin, Ray

    2005-11-01

    The US Army Joint Service Agent Water Monitor (JSAWM) program is currently interested in an approach that can implement a hardware- designed device in ticket-based hand-held assay (currently being developed) used for chemical/biological agent detection. This paper presents a preliminary investigation of the proof of concept. Three components are envisioned to accomplish the task. One is the ticket development which has been undertaken by the ANP, Inc. Another component is the software development which has been carried out by the Remote Sensing Signal and Image Processing Laboratory (RSSIPL) at the University of Maryland, Baltimore County (UMBC). A third component is an embedded system development which can be used to drive the UMBC-developed software to analyze the ANP-developed HHA tickets on a small pocket-size device like a PDA. The main focus of this paper is to investigate the third component that is viable and is yet to be explored. In order to facilitate to prove the concept, a flatbed scanner is used to replace a ticket reader to serve as an input device. The Stargate processor board is used as the embedded System with Embedded Linux installed. It is connected to an input device such as scanner as well as output devices such as LCD display or laptop etc. It executes the C-Coded processing program developed for this embedded system and outputs its findings on a display device. The embedded system to be developed and investigated in this paper is the core of a future hardware device. Several issues arising in such an embedded system will be addressed. Finally, the proof-of-concept pilot embedded system will be demonstrated.

  19. An evaluation of fundus photography and fundus autofluorescence in the diagnosis of cuticular drusen.

    Science.gov (United States)

    Høeg, Tracy B; Moldow, Birgitte; Klein, Ronald; La Cour, Morten; Klemp, Kristian; Erngaard, Ditte; Ellervik, Christina; Buch, Helena

    2016-03-01

    To examine non-mydriatic fundus photography (FP) and fundus autofluorescence (FAF) as alternative non-invasive imaging modalities to fluorescein angiography (FA) in the detection of cuticular drusen (CD). Among 2953 adults from the Danish Rural Eye Study (DRES) with gradable FP, three study groups were selected: (1) All those with suspected CD without age-related macular degeneration (AMD) on FP, (2) all those with suspected CD with AMD on FP and (3) a randomly selected group with early AMD. Groups 1, 2 and 3 underwent FA and FAF and group 4 underwent FAF only as part of DRES CD substudy. Main outcome measures included percentage of correct positive and correct negative diagnoses, Cohen's κ and prevalence-adjusted and bias-adjusted κ (PABAK) coefficients of test and grader reliability. CD was correctly identified on FP 88.9% of the time and correctly identified as not being present 83.3% of the time. CD was correctly identified on FAF 62.0% of the time and correctly identified as not being present 100.0% of the time. Compared with FA, FP has a PABAK of 0.75 (0.60 to 1.5) and FAF a PABAK of 0.44 (0.23 to 0.95). FP is a promising, non-invasive substitute for FA in the diagnosis of CD. FAF was less reliable than FP to detect CD. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. Effect of isoproterenol, phenylephrine, and sodium nitroprusside on fundus pulsations in healthy volunteers.

    OpenAIRE

    Schmetterer, L; Wolzt, M; Salomon, A; Rheinberger, A; Unfried, C; Zanaschka, G; Fercher, A F

    1996-01-01

    AIMS/BACKGROUND: Recently a laser interferometric method for topical measurement of fundus pulsations has been developed. Fundus pulsations in the macular region are caused by the inflow and outflow of blood into the choroid. The purpose of this work was to study the influence of a peripheral vasoconstricting (the alpha 1 adrenoceptor agonist phenylephrine), a predominantly positive inotropic (the non-specific beta adrenoceptor agonist isoproterenol), and a non-specific vasodilating (sodium n...

  1. Absorption Related to Hand-Held Devices in Data Mode

    DEFF Research Database (Denmark)

    Andersen, Jørgen Bach; Nielsen, Jesper Ødum; Pedersen, Gert F.

    2016-01-01

    The human body has an influence on the radiation from handheld devices like smartphones, tablets and laptops, part of the energy is absorbed and the spatial distribution of the radiated part is modified. Previous studies of whole body absorp- tion have mainly been numerical or related to talk mode....... In the present paper an experimental study involving four volunteers and three different devices is performed from 0.5 to 3 GHz. The devices are a laptop, a tablet, and a smartphone all held in the lap. The 3D distribution of radiation is measured. Comparing the integrated power in the case of a person present...

  2. Ophthalmoscopy versus non-mydriatic fundus photography in the ...

    African Journals Online (AJOL)

    The contribution of non-mydriatic fundus photography in the detection of diabetic retinopathy before and after dilatation of the pupils in black diabetics was investigated and compared with direct ophthalmoscopy. Eighty-six patients were examined and good-quality photographs were obtained for 54,7% of eyes before and ...

  3. Vibration produced by hand-held olive electrical harvesters

    Directory of Open Access Journals (Sweden)

    Emanuele Cerruto

    2012-09-01

    Full Text Available The paper reports the results of some laboratory and field tests aimed at assessing the acceleration levels transmitted to the hand-arm system by electric portable harvesters for olive. Four harvesting heads, different for shape and kinematic system, and five bars, different for diameter, length and material (aluminium and carbon fibre, were used in assembling eleven harvesters. The vibrations were measured in two points, next to the handgrips. The laboratory tests allowed the evaluation of the acceleration levels in standard controlled conditions, while the field tests allowed the assessing of the effects of the tree canopy with respect to the no load running. The laboratory tests showed that in reducing the vibration level plays a major role the kinematic system of the harvesting head and then the bar material. The classical flap-type harvester produced accelerations of around 20 m/s2, while by using a harvesting head with two parts in opposite movement, the accelerations were lowered to about 6 m/s2. The use of carbon fibres for the bars, besides the reduction in weight, produced also a reduction in acceleration (from 21 to 16 m/s2. The field tests proved that the tree canopy had a negative effect on the vibrations transmitted to the hand-arm system, especially when the aluminium bar of small diameter was used.

  4. Drusen regression is associated with local changes in fundus autofluorescence in intermediate age-related macular degeneration.

    Science.gov (United States)

    Toy, Brian C; Krishnadev, Nupura; Indaram, Maanasa; Cunningham, Denise; Cukras, Catherine A; Chew, Emily Y; Wong, Wai T

    2013-09-01

    To investigate the association of spontaneous drusen regression in intermediate age-related macular degeneration (AMD) with changes on fundus photography and fundus autofluorescence (FAF) imaging. Prospective observational case series. Fundus images from 58 eyes (in 58 patients) with intermediate AMD and large drusen were assessed over 2 years for areas of drusen regression that exceeded the area of circle C1 (diameter 125 μm; Age-Related Eye Disease Study grading protocol). Manual segmentation and computer-based image analysis were used to detect and delineate areas of drusen regression. Delineated regions were graded as to their appearance on fundus photographs and FAF images, and changes in FAF signal were graded manually and quantitated using automated image analysis. Drusen regression was detected in approximately half of study eyes using manual (48%) and computer-assisted (50%) techniques. At year-2, the clinical appearance of areas of drusen regression on fundus photography was mostly unremarkable, with a majority of eyes (71%) demonstrating no detectable clinical abnormalities, and the remainder (29%) showing minor pigmentary changes. However, drusen regression areas were associated with local changes in FAF that were significantly more prominent than changes on fundus photography. A majority of eyes (64%-66%) demonstrated a predominant decrease in overall FAF signal, while 14%-21% of eyes demonstrated a predominant increase in overall FAF signal. FAF imaging demonstrated that drusen regression in intermediate AMD was often accompanied by changes in local autofluorescence signal. Drusen regression may be associated with concurrent structural and physiologic changes in the outer retina. Published by Elsevier Inc.

  5. Subretinal Fibrosis in Stargardt’s Disease with Fundus Flavimaculatus and ABCA4 Gene Mutation

    Directory of Open Access Journals (Sweden)

    Settimio Rossi

    2012-12-01

    Full Text Available Purpose: To report on 4 patients affected by Stargardt’s disease (STGD with fundus flavimaculatus (FFM and ABCA4 gene mutation associated with subretinal fibrosis. Methods: Four patients with a diagnosis of STGD were clinically examined. All 4 cases underwent a full ophthalmologic evaluation, including best-corrected visual acuity measured by the Snellen visual chart, biomicroscopic examination, fundus examination, fundus photography, electroretinogram, microperimetry, optical coherence tomography and fundus autofluorescence. All patients were subsequently screened for ABCA4 gene mutations, identified by microarray genotyping and confirmed by conventional DNA sequencing of the relevant exons. Results: In all 4 patients, ophthalmologic exam showed areas of subretinal fibrosis in different retinal sectors. In only 1 case, these lesions were correlated to an ocular trauma as confirmed by biomicroscopic examination of the anterior segment that showed a nuclear cataract dislocated to the superior site and vitreous opacities along the lens capsule. The other patients reported a lifestyle characterized by competitive sport activities. The performed instrumental diagnostic investigations confirmed the diagnosis of STGD with FFM in all patients. Moreover, in all 4 affected individuals, mutations in the ABCA4 gene were found. Conclusions: Patients with the diagnosis of STGD associated with FFM can show atypical fundus findings. We report on 4 patients affected by STGD with ABCA4 gene mutation associated with subretinal fibrosis. Our findings suggest that this phenomenon can be accelerated by ocular trauma and also by ocular microtrauma caused by sport activities, highlighting that lifestyle can play a role in the onset of these lesions.

  6. Reliability and reproducibility of disc-foveal angle measurements by non-mydriatic fundus photography

    OpenAIRE

    Le Jeune, Caroline; Chebli, Fayçal; Leon, Lorette; Anthoine, Emmanuelle; Weber, Michel; Péchereau, Alain; Lebranchu, Pierre

    2018-01-01

    Purpose Abnormal torsion could be associated with cyclovertical strabismus, but torsion measurements are not reliable in children. To assess an objective fundus torsion evaluation in a paediatric population, we used Non-Mydriatic Fundus photography (NMFP) in healthy and cyclovertical strabismus patients to evaluate the disc-foveal angle over time and observers. Methods We used a retrospective set of NMFP including 24 A or V-pattern strabismus and 27 age-matched normal children (mean age 6.4 a...

  7. Clinical Investigation of Radiation Retinopathy Fundus and Fluorescein Angiographic Features

    Institute of Scientific and Technical Information of China (English)

    LiMei; QiuGT

    1999-01-01

    Purpose:To investigate the fundus and fluorescein angiographic features in the patients with radiation retinopathy.Clinical Materials:Color fundus photography and/or fluorescein angiography from 13 patients with nasopharyngeal carcinomas received external beam radiation were retrospectively analyzed.Reslts:In this study,26 damaged eyes of 13 patients eveloped some degree of radiation retinopathy.The earliest and most common finding was macular microvascular changes (microaneurysms and/or telangiectasia),which was observed in 100%(26/26)of the eyes.Intraretinal hemorrhages,macular capillary nonperfusion,and macular edema were noted in 84%,50%,and 42% of the eyes,respectively.Conclusions:Radiation retinopathy is common after external beam radiation of nasopharyngeal carcinomas.The prominent changes include maular microvascular changes,intraretinal hemorrhages and macular capillary nonperfusion.

  8. A CAD system and quality assurance protocol for bone age assessment utilizing digital hand atlas

    Science.gov (United States)

    Gertych, Arakadiusz; Zhang, Aifeng; Ferrara, Benjamin; Liu, Brent J.

    2007-03-01

    Determination of bone age assessment (BAA) in pediatric radiology is a task based on detailed analysis of patient's left hand X-ray. The current standard utilized in clinical practice relies on a subjective comparison of the hand with patterns in the book atlas. The computerized approach to BAA (CBAA) utilizes automatic analysis of the regions of interest in the hand image. This procedure is followed by extraction of quantitative features sensitive to skeletal development that are further converted to a bone age value utilizing knowledge from the digital hand atlas (DHA). This also allows providing BAA results resembling current clinical approach. All developed methodologies have been combined into one CAD module with a graphical user interface (GUI). CBAA can also improve the statistical and analytical accuracy based on a clinical work-flow analysis. For this purpose a quality assurance protocol (QAP) has been developed. Implementation of the QAP helped to make the CAD more robust and find images that cannot meet conditions required by DHA standards. Moreover, the entire CAD-DHA system may gain further benefits if clinical acquisition protocol is modified. The goal of this study is to present the performance improvement of the overall CAD-DHA system with QAP and the comparison of the CAD results with chronological age of 1390 normal subjects from the DHA. The CAD workstation can process images from local image database or from a PACS server.

  9. Differential gene expression in the murine gastric fundus lacking interstitial cells of Cajal

    Directory of Open Access Journals (Sweden)

    Ward Sean M

    2003-06-01

    Full Text Available Abstract Background The muscle layers of murine gastric fundus have no interstitial cells of Cajal at the level of the myenteric plexus and only possess intramuscular interstitial cells and this tissue does not generate electric slow waves. The absence of intramuscular interstitial cells in W/WV mutants provides a unique opportunity to study the molecular changes that are associated with the loss of these intercalating cells. Method The gene expression profile of the gastric fundus of wild type and W/WV mice was assayed by murine microarray analysis displaying a total of 8734 elements. Queried genes from the microarray analysis were confirmed by semi-quantitative reverse transcription-polymerase chain reaction. Results Twenty-one genes were differentially expressed in wild type and W/WV mice. Eleven transcripts had 2.0–2.5 fold higher mRNA expression in W/WV gastric fundus when compared to wild type tissues. Ten transcripts had 2.1–3.9 fold lower expression in W/WV mutants in comparison with wild type animals. None of these genes have ever been implicated in any bowel motility function. Conclusions These data provides evidence that several important genes have significantly changed in the murine fundus of W/WV mutants that lack intramuscular interstitial cells of Cajal and have reduced enteric motor neurotransmission.

  10. Automated diagnosis of diabetic retinopathy and glaucoma using fundus and OCT images

    Directory of Open Access Journals (Sweden)

    Pachiyappan Arulmozhivarman

    2012-06-01

    Full Text Available Abstract We describe a system for the automated diagnosis of diabetic retinopathy and glaucoma using fundus and optical coherence tomography (OCT images. Automatic screening will help the doctors to quickly identify the condition of the patient in a more accurate way. The macular abnormalities caused due to diabetic retinopathy can be detected by applying morphological operations, filters and thresholds on the fundus images of the patient. Early detection of glaucoma is done by estimating the Retinal Nerve Fiber Layer (RNFL thickness from the OCT images of the patient. The RNFL thickness estimation involves the use of active contours based deformable snake algorithm for segmentation of the anterior and posterior boundaries of the retinal nerve fiber layer. The algorithm was tested on a set of 89 fundus images of which 85 were found to have at least mild retinopathy and OCT images of 31 patients out of which 13 were found to be glaucomatous. The accuracy for optical disk detection is found to be 97.75%. The proposed system therefore is accurate, reliable and robust and can be realized.

  11. Comparison of film and digital fundus photographs in eyes of individuals with diabetes mellitus

    DEFF Research Database (Denmark)

    Gangaputra, Sapna; Almukhtar, Talat; Glassman, Adam R

    2011-01-01

    To compare grading of diabetic retinopathy (DR) and diabetic macular edema (DME) from stereoscopic film versus stereoscopic digital photographs obtained from a subset of Diabetic Retinopathy Clinical Research Network (DRCR.net) participants.......To compare grading of diabetic retinopathy (DR) and diabetic macular edema (DME) from stereoscopic film versus stereoscopic digital photographs obtained from a subset of Diabetic Retinopathy Clinical Research Network (DRCR.net) participants....

  12. Fundus autofluorescence features of optic disc pit related maculopathy

    African Journals Online (AJOL)

    Fundus autoflorescence (FAF) is a new investigational tool used to identify lipofuscin distribution in the retinal pigment epithelium (RPE) cell monolayer. It has recently been used to analyze age‑related macular degeneration, central serous chorioretinopathy, retina telangiectasia and diffuse and macula retina dystrophies.

  13. [Follow-up on MEWDS by fundus perimetry and multifocal ERG with the SLO].

    Science.gov (United States)

    Bültmann, S; Martin, M; Rohrschneider, K

    2002-09-01

    Most conventional techniques for examination such as perimetry or ERG may not be sensitive enough to detect functional alterations due to MEWDS precisely. We report on a follow-up performed by fundus perimetry and the new technique of multifocal ERG using the scanning laser ophthalmoscope. A 24-year-old female patient (VA 0.2/0.8) was followed up for 7 weeks with these techniques as well as Octopus perimetry, fluorescence angiography, Ganzfeld ERG and biomicroscopy. Multifocal ERG stimulation (mfERG, Retiscan) was performed with the SLO. Visual acuity improved from 0.2 to 0.8 and the central relative scotoma disappeared while a relevant increase of P1-wave amplitudes in mfERG could be observed. Combining objective measurements from the fundus controlled SLO-mfERG and results from fundus perimetry enable good correlation of morphology and results, even for minor alterations of the macula only accessible by few established clinical examinations.

  14. Development of a screening tool for staging of diabetic retinopathy in fundus images

    Science.gov (United States)

    Dhara, Ashis Kumar; Mukhopadhyay, Sudipta; Bency, Mayur Joseph; Rangayyan, Rangaraj M.; Bansal, Reema; Gupta, Amod

    2015-03-01

    Diabetic retinopathy is a condition of the eye of diabetic patients where the retina is damaged because of long-term diabetes. The condition deteriorates towards irreversible blindness in extreme cases of diabetic retinopathy. Hence, early detection of diabetic retinopathy is important to prevent blindness. Regular screening of fundus images of diabetic patients could be helpful in preventing blindness caused by diabetic retinopathy. In this paper, we propose techniques for staging of diabetic retinopathy in fundus images using several shape and texture features computed from detected microaneurysms, exudates, and hemorrhages. The classification accuracy is reported in terms of the area (Az) under the receiver operating characteristic curve using 200 fundus images from the MESSIDOR database. The value of Az for classifying normal images versus mild, moderate, and severe nonproliferative diabetic retinopathy (NPDR) is 0:9106. The value of Az for classification of mild NPDR versus moderate and severe NPDR is 0:8372. The Az value for classification of moderate NPDR and severe NPDR is 0:9750.

  15. Color Fundus Photography versus Fluorescein Angiography in Identification of the Macular Center and Zone in Retinopathy of Prematurity

    Science.gov (United States)

    Patel, Samir N.; Klufas, Michael A.; Ryan, Michael C.; Jonas, Karyn E.; Ostmo, Susan; Martinez-Castellanos, Maria Ana; Berrocal, Audina M.; Chiang, Michael F.; Chan, R.V. Paul

    2016-01-01

    Purpose To examine the utility of fluorescein angiography (FA) in identification of the macular center and the diagnosis of zone in patients with retinopathy of prematurity (ROP). Design Validity and reliability analysis of diagnostic tools Methods 32 sets (16 color fundus photographs; 16 color fundus photographs paired with the corresponding FA) of wide-angle retinal images obtained from 16 eyes of eight infants with ROP were compiled on a secure web site. 9 ROP experts (3 pediatric ophthalmologists; 6 vitreoretinal surgeons) participated in the study. For each image set, experts identified the macular center and provided a diagnosis of zone. Main Outcome Measures (1) Sensitivity and specificity of zone diagnosis (2) “Computer facilitated diagnosis of zone,” based on precise measurement of the macular center, optic disc center, and peripheral ROP. Results Computer facilitated diagnosis of zone agreed with the expert’s diagnosis of zone in 28/45 (62%) cases using color fundus photographs and in 31/45 (69%) cases using FA. Mean (95% CI) sensitivity for detection of zone I by experts as compared to a consensus reference standard diagnosis when interpreting the color fundus images alone versus interpreting the color fundus photographs and FA was 47% (35.3% – 59.3%) and 61.1% (48.9% – 72.4%), respectively, (t(9) ≥ (2.063), p = 0.073). Conclusions There is a marginally significant difference in zone diagnosis when using color fundus photographs compared to using color fundus photographs and the corresponding fluorescein angiograms. There is inconsistency between traditional zone diagnosis (based on ophthalmoscopic exam and image review) compared to a computer-facilitated diagnosis of zone. PMID:25637180

  16. [Fundus autofluorescence in dry AMD - impact on disease progression].

    Science.gov (United States)

    Vidinova, C N; Gouguchkova, P T; Vidinov, K N

    2013-11-01

    Fundus autofluorescence is a novel technique that gives us information about the RPE cells by evaluating the distribution of lipofuscin in the retina. The purpose of our study was to evaluate the diagnostic abilities of OCT, RTVue and fundus autofluorescence in predicting the progression of dry AMD. In our study 37 dry AMD patients were enrolled: 22 of them with druses and 15 with developed geographic atrophy. They all underwent complete ophthalmological examinations including OCT and autofluorescence. We used the RTVue OCT programmes HD line, Cross line, EMM5 and EMM5 progression in all cases. The autofluorescence was recorded with the help of the Canon CX1 fundus camera. OCT images in the AMD patients with dry AMD and large druses showed typical undulations in the RPE/choroid line and occasionally drusenoid detachment of the RPE. Autofluorescence showed different patterns. The confluent reticular autofluorescence was associated with the development of neovascular membranes. In geographic atrophy patient OCTs showed diminished retinal thickness measured with EMM5. On autofluorescence the findings at the border zone atrophic/normal retina were of particular importance. The diffuse increased autofluorescence in that area was considered to be a sign for further atrophy progression. Our results point out that OCT in combination with autofluorescence is important in following the progression of dry AMD. Pathological autofluorescence at the border of atrophic lesions is an important sign for disease activity. Although both OCT and autofluorescence visualise the changes in RPE, autofluorescence is of key importance in predicting the development of the disease. Georg Thieme Verlag KG Stuttgart · New York.

  17. Joint optic disc and cup boundary extraction from monocular fundus images.

    Science.gov (United States)

    Chakravarty, Arunava; Sivaswamy, Jayanthi

    2017-08-01

    Accurate segmentation of optic disc and cup from monocular color fundus images plays a significant role in the screening and diagnosis of glaucoma. Though optic cup is characterized by the drop in depth from the disc boundary, most existing methods segment the two structures separately and rely only on color and vessel kink based cues due to the lack of explicit depth information in color fundus images. We propose a novel boundary-based Conditional Random Field formulation that extracts both the optic disc and cup boundaries in a single optimization step. In addition to the color gradients, the proposed method explicitly models the depth which is estimated from the fundus image itself using a coupled, sparse dictionary trained on a set of image-depth map (derived from Optical Coherence Tomography) pairs. The estimated depth achieved a correlation coefficient of 0.80 with respect to the ground truth. The proposed segmentation method outperformed several state-of-the-art methods on five public datasets. The average dice coefficient was in the range of 0.87-0.97 for disc segmentation across three datasets and 0.83 for cup segmentation on the DRISHTI-GS1 test set. The method achieved a good glaucoma classification performance with an average AUC of 0.85 for five fold cross-validation on RIM-ONE v2. We propose a method to jointly segment the optic disc and cup boundaries by modeling the drop in depth between the two structures. Since our method requires a single fundus image per eye during testing it can be employed in the large-scale screening of glaucoma where expensive 3D imaging is unavailable. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Automatic computer-aided diagnosis of retinal nerve fiber layer defects using fundus photographs in optic neuropathy.

    Science.gov (United States)

    Oh, Ji Eun; Yang, Hee Kyung; Kim, Kwang Gi; Hwang, Jeong-Min

    2015-05-01

    To evaluate the validity of an automatic computer-aided diagnosis (CAD) system for detection of retinal nerve fiber layer (RNFL) defects on fundus photographs of glaucomatous and nonglaucomatous optic neuropathy. We have proposed an automatic detection method for RNFL defects on fundus photographs in various cases of glaucomatous and nonglaucomatous optic neuropathy. In order to detect the vertical dark bands as candidate RNFL defects, the nonuniform illumination of the fundus image was corrected, the blood vessels were removed, and the images were converted to polar coordinates with the center of the optic disc. False positives (FPs) were reduced by using knowledge-based rules. The sensitivity and FP rates for all images were calculated. We tested 98 fundus photographs with 140 RNFL defects and 100 fundus photographs of healthy normal subjects. The proposed method achieved a sensitivity of 90% and a 0.67 FP rate per image and worked well with RNFL defects with variable depths and widths, with uniformly high detection rates regardless of the angular widths of the RNFL defects. The average detection accuracy was approximately 0.94. The overall diagnostic accuracy of the proposed algorithm for detecting RNFL defects among 98 patients and 100 healthy individuals was 86% sensitivity and 75% specificity. The proposed CAD system successfully detected RNFL defects in optic neuropathies. Thus, the proposed algorithm is useful for the detection of RNFL defects.

  19. [Fundus Autofluorescence Imaging].

    Science.gov (United States)

    Schmitz-Valckenberg, S

    2015-09-01

    Fundus autofluorescence (FAF) imaging allows for non-invasive mapping of changes at the level of the retinal pigment epithelium/photoreceptor complex and of alterations of macular pigment distribution. This imaging method is based on the visualisation of intrinsic fluorophores and may be easily and rapidly used in routine patient care. Main applications include degenerative disorders of the outer retina such as age-related macular degeneration, hereditary and acquired retinal diseases. FAF imaging is particularly helpful for differential diagnosis, detection and extent of involved retinal areas, structural-functional correlations and monitoring of changes over time. Recent developments include - in addition to the original application of short wavelength light for excitation ("blue" FAF imaging) - the use of other wavelength ranges ("green" or "near-infrared" FAF imaging), widefield imaging for visualisation of peripheral retinal areas and quantitative FAF imaging. Georg Thieme Verlag KG Stuttgart · New York.

  20. Four dimensional hybrid ultrasound and optoacoustic imaging via passive element optical excitation in a hand-held probe

    Science.gov (United States)

    Fehm, Thomas Felix; Deán-Ben, Xosé Luís; Razansky, Daniel

    2014-10-01

    Ultrasonography and optoacoustic imaging share powerful advantages related to the natural aptitude for real-time image rendering with high resolution, the hand-held operation, and lack of ionizing radiation. The two methods also possess very different yet highly complementary advantages of the mechanical and optical contrast in living tissues. Nonetheless, efficient integration of these modalities remains challenging owing to the fundamental differences in the underlying physical contrast, optimal signal acquisition, and image reconstruction approaches. We report on a method for hybrid acquisition and reconstruction of three-dimensional pulse-echo ultrasound and optoacoustic images in real time based on passive ultrasound generation with an optical absorber, thus avoiding the hardware complexity of active ultrasound generation. In this way, complete hybrid datasets are generated with a single laser interrogation pulse, resulting in simultaneous rendering of ultrasound and optoacoustic images at an unprecedented rate of 10 volumetric frames per second. Performance is subsequently showcased in phantom experiments and in-vivo measurements from a healthy human volunteer, confirming general clinical applicability of the method.

  1. Four dimensional hybrid ultrasound and optoacoustic imaging via passive element optical excitation in a hand-held probe

    International Nuclear Information System (INIS)

    Fehm, Thomas Felix; Razansky, Daniel; Deán-Ben, Xosé Luís

    2014-01-01

    Ultrasonography and optoacoustic imaging share powerful advantages related to the natural aptitude for real-time image rendering with high resolution, the hand-held operation, and lack of ionizing radiation. The two methods also possess very different yet highly complementary advantages of the mechanical and optical contrast in living tissues. Nonetheless, efficient integration of these modalities remains challenging owing to the fundamental differences in the underlying physical contrast, optimal signal acquisition, and image reconstruction approaches. We report on a method for hybrid acquisition and reconstruction of three-dimensional pulse-echo ultrasound and optoacoustic images in real time based on passive ultrasound generation with an optical absorber, thus avoiding the hardware complexity of active ultrasound generation. In this way, complete hybrid datasets are generated with a single laser interrogation pulse, resulting in simultaneous rendering of ultrasound and optoacoustic images at an unprecedented rate of 10 volumetric frames per second. Performance is subsequently showcased in phantom experiments and in-vivo measurements from a healthy human volunteer, confirming general clinical applicability of the method.

  2. Four dimensional hybrid ultrasound and optoacoustic imaging via passive element optical excitation in a hand-held probe

    Energy Technology Data Exchange (ETDEWEB)

    Fehm, Thomas Felix; Razansky, Daniel, E-mail: dr@tum.de [Institute for Biological and Medical Imaging (IBMI), Helmholtz Zentrum München, Neuherberg (Germany); Faculty of Medicine, Technische Universität München, Munich (Germany); Deán-Ben, Xosé Luís [Institute for Biological and Medical Imaging (IBMI), Helmholtz Zentrum München, Neuherberg (Germany)

    2014-10-27

    Ultrasonography and optoacoustic imaging share powerful advantages related to the natural aptitude for real-time image rendering with high resolution, the hand-held operation, and lack of ionizing radiation. The two methods also possess very different yet highly complementary advantages of the mechanical and optical contrast in living tissues. Nonetheless, efficient integration of these modalities remains challenging owing to the fundamental differences in the underlying physical contrast, optimal signal acquisition, and image reconstruction approaches. We report on a method for hybrid acquisition and reconstruction of three-dimensional pulse-echo ultrasound and optoacoustic images in real time based on passive ultrasound generation with an optical absorber, thus avoiding the hardware complexity of active ultrasound generation. In this way, complete hybrid datasets are generated with a single laser interrogation pulse, resulting in simultaneous rendering of ultrasound and optoacoustic images at an unprecedented rate of 10 volumetric frames per second. Performance is subsequently showcased in phantom experiments and in-vivo measurements from a healthy human volunteer, confirming general clinical applicability of the method.

  3. Common input to motor units of intrinsic and extrinsic hand muscles during two-digit object hold.

    Science.gov (United States)

    Winges, Sara A; Kornatz, Kurt W; Santello, Marco

    2008-03-01

    Anatomical and physiological evidence suggests that common input to motor neurons of hand muscles is an important neural mechanism for hand control. To gain insight into the synaptic input underlying the coordination of hand muscles, significant effort has been devoted to describing the distribution of common input across motor units of extrinsic muscles. Much less is known, however, about the distribution of common input to motor units belonging to different intrinsic muscles and to intrinsic-extrinsic muscle pairs. To address this void in the literature, we quantified the incidence and strength of near-simultaneous discharges of motor units residing in either the same or different intrinsic hand muscles (m. first dorsal, FDI, and m. first palmar interosseus, FPI) during two-digit object hold. To extend the characterization of common input to pairs of extrinsic muscles (previous work) and pairs of intrinsic muscles (present work), we also recorded electromyographic (EMG) activity from an extrinsic thumb muscle (m. flexor pollicis longus, FPL). Motor-unit synchrony across FDI and FPI was weak (common input strength, CIS, mean +/- SE: 0.17 +/- 0.02). Similarly, motor units from extrinsic-intrinsic muscle pairs were characterized by weak synchrony (FPL-FDI: 0.25 +/- 0.02; FPL-FPI: 0.29 +/- 0.03) although stronger than FDI-FPI. Last, CIS from within FDI and FPI was more than three times stronger (0.70 +/- 0.06 and 0.66 +/- 0.06, respectively) than across these muscles. We discuss present and previous findings within the framework of muscle-pair specific distribution of common input to hand muscles based on their functional role in grasping.

  4. Survey of Munitions Response Technologies

    Science.gov (United States)

    2006-06-01

    item. EMI detectors are operated in either time domain (TD) or frequency domain (FD). A common example of a hand-held EMI sensor is the 3-1 metal ...held Digital Emerging Fisher 1266-X Metal Detector Hand-held Analog Established Foerster MINEX 2FD 4.500 Hand-held Analog Established Minelab...ferrous and nonferrous metallic objects. • Effective in detecting near-surface objects. • Can be effective in geology that challenges magnetometers

  5. Digitalization of the second finger in type 2 central longitudinal deficiencies (clefting) of the hand.

    Science.gov (United States)

    Oberlin, Christophe; Korchi, Amar; Belkheyar, Zoubir; Touam, Chabane; Macquillan, Anthony

    2009-06-01

    In central longitudinal deficiency of the hand type 2 (Manske and Halikis), the second finger presents itself anatomically and functionally as a second thumb. It is therefore necessary to undertake digitalization of the index, performed exactly as a reverse pollicization technique, with the same principles: minimum volar scarring and reconstruction of a large first web space without scars at the fold of the commissure. The incision surrounds the second digit at the level of the midproximal phalanx, extends over the dorsal edge of the cleft, and finishes on the radial side of the third finger where the second web space is to be created. Through this approach, the index metacarpal is freed (extraperiosteally), preserving the dorsal venous network, and translocated into the space of the missing third ray. After internal bone fixation, the flap, with its wide and safe volar cutaneous pedicle, is easily transposed to reconstruct the first web space, avoiding the need for skin grafting. This technique is easier and safer and does not impair the normal thumb musculature compared with the classic Snow-Littler procedure.

  6. Automatic segmentation of blood vessels from retinal fundus images ...

    Indian Academy of Sciences (India)

    The retinal blood vessels were segmented through color space conversion and color channel .... Retinal blood vessel segmentation was also attempted through multi-scale operators. A few works in this ... fundus camera at 35 degrees field of view. The image ... vessel segmentation is available from two human observers.

  7. Incidence of fundus oculi and neurocranium changes in patients with migraine in the community

    Directory of Open Access Journals (Sweden)

    M. Musić

    2005-02-01

    Full Text Available The purpose of this study was to monitor possible changes of fundus oculi and neurocranim in patients with migraine according to their gender, place of residence and education grade. In a significantpercentageofourpatients with migraine there were no changes of fundus oculi, CT neurocranium or craniogram. The reason of significantmigrainemorbidityinruralzones,inpatientswithlowereducationgrade,andalmostequalproportionof male and female patients with tendency of the disease to older age groups, remains unclear. There is a need for further research.

  8. Cost Model for Digital Preservation: Cost of Digital Migration

    DEFF Research Database (Denmark)

    Kejser, Ulla Bøgvad; Nielsen, Anders Bo; Thirifays, Alex

    2011-01-01

    The Danish Ministry of Culture has funded a project to set up a model for costing preservation of digital materials held by national cultural heritage institutions. The overall objective of the project was to increase cost effectiveness of digital preservation activities and to provide a basis...... for comparing and estimating future cost requirements for digital preservation. In this study we describe an activity-based costing methodology for digital preservation based on the Open Archice Information System (OAIS) Reference Model. Within this framework, which we denote the Cost Model for Digital...... Preservation (CMDP), the focus is on costing the functional entity Preservation Planning from the OAIS and digital migration activities. In order to estimate these costs we have identified cost-critical activities by analysing the functions in the OAIS model and the flows between them. The analysis has been...

  9. Early simultaneous fundus autofluorescence and optical coherence tomography features after pars plana vitrectomy for primary rhegmatogenous retinal detachment.

    Science.gov (United States)

    Dell'Omo, Roberto; Mura, Marco; Lesnik Oberstein, Sarit Y; Bijl, Heico; Tan, H Stevie

    2012-04-01

    To describe fundus autofluorescence and optical coherence tomography (OCT) features of the macula after pars plana vitrectomy for rhegmatogenous retinal detachment. Thirty-three eyes of 33 consecutive patients with repaired rhegmatogenous retinal detachment with or without the involvement of the macula were prospectively investigated with simultaneous fundus autofluorescence and OCT imaging using the Spectralis HRA+OCT (Heidelberg Engineering, Heidelberg, Germany) within a few weeks after the operation. Fundus autofluorescence imaging of the macula showed lines of increased and decreased autofluorescence in 19 cases (57.6%). On OCT, these lines corresponded to the following abnormalities: outer retinal folds, inner retinal folds, and skip reflectivity abnormalities of the photoreceptor inner segment/outer segment band. Other OCT findings, not related to abnormal lines on fundus autofluorescence, consisted of disruption of photoreceptor inner segment/outer segment band and collection of intraretinal or subretinal fluid. The presence of outer retinal folds significantly related to metamorphopsia but did not relate to poor postoperative visual acuity. Partial-thickness retinal folds occur commonly after vitrectomy for rhegmatogenous retinal detachment repair and may represent an important anatomical substrate for postoperative metamorphopsia. Fundus autofluorescence and OCT are both sensitive techniques for the detection of these abnormalities.

  10. Enhanced depth imaging optical coherence tomography and fundus autofluorescence findings in bilateral choroidal osteoma: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Erol, Muhammet Kazim; Coban, Deniz Turgut; Ceran, Basak Bostanci; Bulut, Mehmet, E-mail: muhammetkazimerol@gmail.com [Kazim Erol. Antalya Training and Research Hospital, Ophthalmology Department, Antalya (Turkey)

    2013-11-01

    The authors present enhanced depth imaging optical coherence tomography (EDI OCT) and fundus autofluorescence (FAF) characteristics of a patient with bilateral choroidal osteoma and try to make a correlation between two imaging techniques. Two eyes of a patient with choroidal osteoma underwent complete ophthalmic examination. Enhanced depth imaging optical coherence tomography revealed a cage-like pattern, which corresponded to the calcified region of the tumor. Fundus autofluorescence imaging of the same area showed slight hyperautofluorescence. Three different reflectivity patterns in the decalcified area were defined. In the areas of subretinal fluid, outer segment elongations similar to central serous chorioretinopathy were observed. Hyperautofluorescent spots were evident in fundus autofluorescence in the same area. Calcified and decalcified portions of choroidal osteoma as well as the atrophy of choriocapillaris demonstrated different patterns with enhanced depth imaging and fundus autofluorescence imaging. Both techniques were found to be beneficial in the diagnosis and follow-up of choroidal osteoma. (author)

  11. Enhanced depth imaging optical coherence tomography and fundus autofluorescence findings in bilateral choroidal osteoma: a case report

    International Nuclear Information System (INIS)

    Erol, Muhammet Kazim; Coban, Deniz Turgut; Ceran, Basak Bostanci; Bulut, Mehmet

    2013-01-01

    The authors present enhanced depth imaging optical coherence tomography (EDI OCT) and fundus autofluorescence (FAF) characteristics of a patient with bilateral choroidal osteoma and try to make a correlation between two imaging techniques. Two eyes of a patient with choroidal osteoma underwent complete ophthalmic examination. Enhanced depth imaging optical coherence tomography revealed a cage-like pattern, which corresponded to the calcified region of the tumor. Fundus autofluorescence imaging of the same area showed slight hyperautofluorescence. Three different reflectivity patterns in the decalcified area were defined. In the areas of subretinal fluid, outer segment elongations similar to central serous chorioretinopathy were observed. Hyperautofluorescent spots were evident in fundus autofluorescence in the same area. Calcified and decalcified portions of choroidal osteoma as well as the atrophy of choriocapillaris demonstrated different patterns with enhanced depth imaging and fundus autofluorescence imaging. Both techniques were found to be beneficial in the diagnosis and follow-up of choroidal osteoma. (author)

  12. Enhanced depth imaging optical coherence tomography and fundus autofluorescence findings in bilateral choroidal osteoma: a case report

    Directory of Open Access Journals (Sweden)

    Muhammet Kazim Erol

    2013-06-01

    Full Text Available The authors present enhanced depth imaging optical coherence tomography (EDI OCT and fundus autofluorescence (FAF characteristics of a patient with bilateral choroidal osteoma and try to make a correlation between two imaging techniques. Two eyes of a patient with choroidal osteoma underwent complete ophthalmic examination. Enhanced depth imaging optical coherence tomography revealed a cage-like pattern, which corresponded to the calcified region of the tumor. Fundus autofluorescence imaging of the same area showed slight hyperautofluorescence. Three different reflectivity patterns in the decalcified area were defined. In the areas of subretinal fluid, outer segment elongations similar to central serous chorioretinopathy were observed. Hyperautofluorescent spots were evident in fundus autofluorescence in the same area. Calcified and decalcified portions of choroidal osteoma as well as the atrophy of choriocapillaris demonstrated different patterns with enhanced depth imaging and fundus autofluorescence imaging. Both techniques were found to be beneficial in the diagnosis and follow-up of choroidal osteoma.

  13. Digital imaging in cardiovascular radiology

    International Nuclear Information System (INIS)

    Heintzen, P.H.; Brennecke, R.

    1983-01-01

    The present book contains 27 papers presented at an international symposium on digital imaging in cardiovascular radiology held in Kiel in 1982. The main themes were as follows. Introductory reviews, digital systems for X-ray video imaging, quantitative X-ray image analysis, and clinical applications. (MG)

  14. Hand burns surface area: A rule of thumb.

    Science.gov (United States)

    Dargan, Dallan; Mandal, Anirban; Shokrollahi, Kayvan

    2018-03-11

    Rapid estimation of acute hand burns is important for communication, standardisation of assessment, rehabilitation and research. Use of an individual's own thumbprint area as a fraction of their total hand surface area was evaluated to assess potential utility in hand burn evaluation. Ten health professionals used an ink-covered dominant thumb pulp to cover the surfaces of their own non-dominant hand using the contralateral thumb. Thumbprints were assessed on the web spaces, sides of digits and dorsum and palm beyond the distal wrist crease. Hand surface area was estimated using the Banerjee and Sen method, and thumbprint ellipse area calculated to assess correlation. Mean estimated total hand surface area was 390.0cm 2 ±SD 51.5 (328.3-469.0), mean thumbprint ellipse area was 5.5cm 2 ±SD 1.3 (3.7-8.4), and mean estimated print number was 73.5±SD 11.0 (range 53.1-87.8, 95% CI 6.8). The mean observed number of thumbprints on one hand was 80.1±SD 5.9 (range 70.0-88.0, 95% CI 3.7), χ 2 =0.009. The combined mean of digital prints was 42, comprising a mean of two prints each on volar, dorsal, radial and ulnar digit surfaces, except volar middle and ring (3 prints each). Palmar prints were 15 (11-19), dorsal 15 (11-19), ulnar palm border 3, first web space 2, and second, third and fourth web spaces one each. Using the surface of the palm alone, excluding digits, as 0.5% of total body surface area, the area of one thumbprint was approximated as 1/30th of 1%. We have demonstrated how thumbprint area serves as a simple method for evaluating hand burn surface area. Copyright © 2018 Elsevier Ltd and ISBI. All rights reserved.

  15. Quantitative fundus autofluorescence in healthy eyes.

    Science.gov (United States)

    Greenberg, Jonathan P; Duncker, Tobias; Woods, Russell L; Smith, R Theodore; Sparrow, Janet R; Delori, François C

    2013-08-21

    Fundus autofluorescence was quantified (qAF) in subjects with healthy retinae using a standardized approach. The objective was to establish normative data and identify factors that influence the accumulation of RPE lipofuscin and/or modulate the observed AF signal in fundus images. AF images were acquired from 277 healthy subjects (age range: 5-60 years) by employing a Spectralis confocal scanning laser ophthalmoscope (cSLO; 488-nm excitation; 30°) equipped with an internal fluorescent reference. For each image, mean gray level was calculated as the average of eight preset regions, and was calibrated to the reference, zero-laser light, magnification, and optical media density from normative data on lens transmission spectra. Relationships between qAF and age, sex, race/ethnicity, eye color, refraction/axial length, and smoking status were evaluated as was measurement repeatability and the qAF spatial distribution. qAF levels exhibited a significant increase with age. qAF increased with increasing eccentricity up to 10° to 15° from the fovea and was highest superotemporally. qAF values were significantly greater in females, and, compared with Hispanics, qAF was significantly higher in whites and lower in blacks and Asians. No associations with axial length and smoking were observed. For two operators, between-session repeatability was ± 9% and ± 12%. Agreement between the operators was ± 13%. Normative qAF data are a reference tool essential to the interpretation of qAF measurements in ocular disease.

  16. Ultra-wide field imaging system and traditional retinal examinations for screening fundus changes after cataract surgery.

    Science.gov (United States)

    Peng, Jie; Zhang, Qi; Jin, Hai-Ying; Lu, Wu-Yi; Zhao, Pei-Quan

    2016-01-01

    To compare the results of non-mydriatic ultra-wide field imaging system, mydriatic slit-lamp lens (Volk +90 D) and mydriatic Goldmann three-mirror contact lens examinations in screening fundus lesions among patients after cataract surgery. Non-mydriatic images were obtained with an Optomap panoramic 200Tx (Optomap 200Tx) 3d after surgery and graded by a blinded ophthalmologist. A mydriatic slit-lamp lens examination was performed by another blinded retinal specialist on the same day. A third blinded retinal specialist examined patients two weeks after surgery using a Goldmann three-mirror contact lens. In total, 160 patients (184 eyes) were examined, and 66, 69, and 75 cases of retinal lesion(s) were identified using the Optomap 200Tx, slit-lamp lens, and Goldmann three-mirror contact lens, respectively. In 13 cases, fundus changes were sight-threatening. The results obtained by Optomap 200Tx examination and by mydriatic slit-lamp lens examination have good consistency (P=0.375, Kappa=0.942). The mydriatic Goldmann three-mirror lens examination revealed more fundus lesions but are consistent with Optomap 200Tx (P=0.004, Kappa=0.897) and mydriatic slit-lamp lens examination (P=0.031, Kappa=0.932). Early post-operative fundus screening in cataract patients is extremely important and necessary to prevent further vision loss. Wide-field imaging is a feasible and convenient tool for fundus examination that can be used as a primary screening method among patients after cataract surgery.

  17. Use of a hand-held bladder ultrasound scanner in the assessment of dehydration and monitoring response to treatment in a paediatric emergency department.

    Science.gov (United States)

    Enright, Kevin; Beattie, Tom; Taheri, Sepideh

    2010-10-01

    Dehydration is a common concern in paediatric emergency care. Limited tools are available to assess reduced urine production, which is commonly cited as a reliable marker of dehydration. To evaluate the utility of a hand-held bladder ultrasound scanner in monitoring urine production in children attending the emergency department with suspected dehydration. A prospective pilot study was undertaken on a convenience sample of patients presenting with suspected dehydration. Serial bladder ultrasound scanning was performed to monitor urine output. Dehydration was assessed clinically using the WHO guide to dehydration assessment. Decisions about treatment and admission were made independently of the urine output measurements obtained using the bladder scanner. 45 children were studied. Using the WHO guide, 33 (73%) had mild dehydration, 8 (18%) had moderate dehydration and 4 (9%) had severe dehydration. There was a significant difference in estimated urine production between those admitted and those discharged (0.9±1.2 ml/kg/h vs 1.8±1.5 ml/kg/h, p=0.01) and between those with mild dehydration versus moderate/severe dehydration (2.3±1.5 ml/kg/h vs 0.6±0.7 ml/kg/h, p=0.0011). Urine output had been significantly reduced in those who had received an intravenous fluid bolus compared with those who had not (0.4±0.46 ml/kg/h vs 1.9±1.6 ml/kg/h, p=0.001). The hand-held bladder scanner is a convenient, non-invasive and objective adjunct in the assessment and management of children attending the emergency department with suspected dehydration.

  18. Integrated optical detection of autonomous capillary microfluidic immunoassays:a hand-held point-of-care prototype.

    Science.gov (United States)

    Novo, P; Chu, V; Conde, J P

    2014-07-15

    The miniaturization of biosensors using microfluidics has potential in enabling the development of point-of-care devices, with the added advantages of reduced time and cost of analysis with limits-of-detection comparable to those obtained through traditional laboratory techniques. Interfacing microfluidic devices with the external world can be difficult especially in aspects involving fluid handling and the need for simple sample insertion that avoids special equipment or trained personnel. In this work we present a point-of-care prototype system by integrating capillary microfluidics with a microfabricated photodiode array and electronic instrumentation into a hand-held unit. The capillary microfluidic device is capable of autonomous and sequential fluid flow, including control of the average fluid velocity at any given point of the analysis. To demonstrate the functionality of the prototype, a model chemiluminescence ELISA was performed. The performance of the integrated optical detection in the point-of-care prototype is equal to that obtained with traditional bench-top instrumentation. The photodiode signals were acquired, displayed and processed by a simple graphical user interface using a computer connected to the microcontroller through USB. The prototype performed integrated chemiluminescence ELISA detection in about 15 min with a limit-of-detection of ≈2 nM with an antibody-antigen affinity constant of ≈2×10(7) M(-1). Copyright © 2014 Elsevier B.V. All rights reserved.

  19. 数码彩色眼底照相对糖尿病视网膜病变早期诊断模式的研究%Role of Ocular Fundus Imaging in Research of Early Diagnostic Mode for Diabetic Retinopathy

    Institute of Scientific and Technical Information of China (English)

    王中颖

    2012-01-01

    目的 采用直接眼底镜检查、数码彩色眼底照相、荧光素眼底血管造影及光学相干断层扫描等4种方法,对糖尿病视网膜病变患者进行检查和评估,探讨早期糖尿病视网膜病变筛查方法.方法 对2009年1月~2010年1月就诊我院眼科门诊的糖尿病患者,进行直接眼底镜检查、数码彩色眼底照相、荧光素眼底血管造影及光学相干断层扫描检查.以荧光素眼底血管造影诊断为标准,分析各种检查结果的敏感性、特异性及与眼底荧光血管造影诊断的一致性.结果 以糖尿病视网膜病变l期为筛查阈值时,眼底彩色照相的敏感性、特异性均明显高于直接眼底镜检查,Kappa检验有高度一致性;以糖尿病视网膜病变2期为筛查阈值时,直接眼底镜检查与眼底彩色照相的特异性基本一致,但眼底彩色照相的敏感性明显高于直接眼底镜检查,Kappa检验有高度一致性.同正常组相比,糖尿病视网膜病变1期视网膜各方位厚度并无明显增加,糖尿病视网膜病变2期各方位神经上皮层厚度比相应方位的正常组增加.结论 数码彩色眼底照相可作为糖尿病视网膜病变2期以上患者的主要筛查诊断方法.%Objective Diabetic retinopathy (DR) in patients with diabetic mellitus (DM) are estimated and detected through direct funduscopy, digital fundus imaging, fundus fluorescein angiography (FFA) and optical coherence tomography (OCT). Methods All diabetes who received examination in ophthalmic outpatient department of our hospital underwent direct funduscopy, digital fundus imaging, FFA and OCX, Then taking the diagnosis of FFA as the standard, we could not only analyse the sensitivity and specificity, but also analyse consistency diagnosed by FFA, Macular thickness in all the quadrants and foveal volume were evaluated. Results When diabetic retinopathy in first stage is being taken as referable DR threshold, ocular digital fundus imaging gave

  20. Cognitive Hacking and Digital Government: Digital Identity

    Directory of Open Access Journals (Sweden)

    Paul Thompson

    2004-04-01

    Full Text Available Recently the National Center for Digital Government held a workshop on "The Virtual Citizen: Identity, Autonomy, and Accountability: A Civic Scenario Exploration of the Role of Identity in On-Line. Discussions at the workshop focused on five scenarios for future authentication policies with respect to digital identity. The underlying technologies considered for authentication were: biometrics: cryptography, with a focus on digital signatures; secure processing/computation; and reputation systems. Most discussion at the workshop focused on issues related to authentication of users of digital government, but, as implied by the inclusion of a scenario related to ubiquitous identity theft, there was also discussion of problems related to misinformation, including cognitive hacking. Cognitive hacking refers to a computer or information system attack that relies on changing human users' perceptions and corresponding behaviors in order to succeed. This paper describes cognitive hacking, suggests countermeasures, and discusses the implications of cognitive hacking for identity in digital government. In particular, spoofing of government websites and insider misuse are considered.

  1. Optic disc boundary segmentation from diffeomorphic demons registration of monocular fundus image sequences versus 3D visualization of stereo fundus image pairs for automated early stage glaucoma assessment

    Science.gov (United States)

    Gatti, Vijay; Hill, Jason; Mitra, Sunanda; Nutter, Brian

    2014-03-01

    Despite the current availability in resource-rich regions of advanced technologies in scanning and 3-D imaging in current ophthalmology practice, world-wide screening tests for early detection and progression of glaucoma still consist of a variety of simple tools, including fundus image-based parameters such as CDR (cup to disc diameter ratio) and CAR (cup to disc area ratio), especially in resource -poor regions. Reliable automated computation of the relevant parameters from fundus image sequences requires robust non-rigid registration and segmentation techniques. Recent research work demonstrated that proper non-rigid registration of multi-view monocular fundus image sequences could result in acceptable segmentation of cup boundaries for automated computation of CAR and CDR. This research work introduces a composite diffeomorphic demons registration algorithm for segmentation of cup boundaries from a sequence of monocular images and compares the resulting CAR and CDR values with those computed manually by experts and from 3-D visualization of stereo pairs. Our preliminary results show that the automated computation of CDR and CAR from composite diffeomorphic segmentation of monocular image sequences yield values comparable with those from the other two techniques and thus may provide global healthcare with a cost-effective yet accurate tool for management of glaucoma in its early stage.

  2. FUNDUS AUTOFLUORESCENCE IN RUBELLA RETINOPATHY: Correlation With Photoreceptor Structure and Function.

    Science.gov (United States)

    Bukowska, Danuta M; Wan, Sue Ling; Chew, Avenell L; Chelva, Enid; Tang, Ivy; Mackey, David A; Chen, Fred K

    2017-01-01

    To illustrate altered fundus autofluorescence in rubella retinopathy and to investigate their relationships with photoreceptor structure and function using multimodal imaging. The authors report four cases of rubella retinopathy aged 8, 33, 42, and 50 years. All patients had dilated clinical fundus examination; wide-field color photography; blue, green, and near-infrared autofluorescence imaging and spectral domain optical coherence tomography. Two patients also underwent microperimetry and adaptive optics imaging. En face optical coherence tomography, cone mosaic, and microperimetry were coregistered with autofluorescence images. The authors explored the structure-function correlation. All four patients had a "salt-and-pepper" appearance on dilated fundus examination and wide-field color photography. There were variable-sized patches of hypoautofluorescence on both blue and near-infrared excitation in all four patients. Wave-guiding cones were visible and retinal sensitivity was intact over these regions. There was no correlation between hypoautofluorescence and regions of attenuated ellipsoid and interdigitation zones. Hyperautofluorescent lesions were also noted and some of these were pseudo-vitelliform lesions. Patchy hypoautofluorescence on near-infrared excitation can be a feature of rubella retinopathy. This may be due to abnormal melanin production or loss of melanin within retinal pigment epithelium cells harboring persistent rubella virus infection. Preservation of the ellipsoid zone, wave-guiding cones, and retinal sensitivity within hypoautofluorescent lesions suggest that these retinal pigment epithelium changes have only mild impact on photoreceptor cell function.

  3. Validation of Ankle Strength Measurements by Means of a Hand-Held Dynamometer in Adult Healthy Subjects

    Directory of Open Access Journals (Sweden)

    Andrea Ancillao

    2017-01-01

    Full Text Available Uniaxial Hand-Held Dynamometer (HHD is a low-cost device widely adopted in clinical practice to measure muscle force. HHD measurements depend on operator’s ability and joint movements. The aim of the work is to validate the use of a commercial HHD in both dorsiflexion and plantarflexion ankle strength measurements quantifying the effects of HHD misplacements and unwanted foot’s movements on the measurements. We used an optoelectronic system and a multicomponent load cell to quantify the sources of error in the manual assessment of the ankle strength due to both the operator’s ability to hold still the HHD and the transversal components of the exerted force that are usually neglected in clinical routine. Results showed that foot’s movements and angular misplacements of HHD on sagittal and horizontal planes were relevant sources of inaccuracy on the strength assessment. Moreover, ankle dorsiflexion and plantarflexion force measurements presented an inaccuracy less than 2% and higher than 10%, respectively. In conclusion, the manual use of a uniaxial HHD is not recommended for the assessment of ankle plantarflexion strength; on the contrary, it can be allowed asking the operator to pay strong attention to the HHD positioning in ankle dorsiflexion strength measurements.

  4. User certification of hand-held x-ray tube based analytical fluorescent devices in a canadian context

    International Nuclear Information System (INIS)

    Maharaj, H.P.

    2005-01-01

    Safety education aims to reduce personal injury and improve well being. This health promotion principle is applied in the case of hand-held open beam x-ray tube based analytical x-ray devices. Such devices not only are light weight and portable, but also present high radiation exposure levels at the beam exit port and potentially can be used in a variety of industrial applications for determination of material composition. There is much potential for radiation risks to occur with resultant adverse effects if such devices are not used by trained individuals within controlled environments. A level of radiation safety knowledge and understanding of the device design, construction and performance characteristics appear warranted. To reduce radiation risks, user certification at a federal level was introduced in 2004 based on International Standards Organization 20807, since that standard comprises elements commensurate with risk reduction strategies. Within these contexts, a federally certified user is deemed to have acquired a level of safety knowledge and skills to facilitate safe use of the device. Certification, however, does not absolve the holder from obligations of compliance with applicable provincial, territorial or federal laws respecting device operation. The union of federal certification and applicable legislative mandated operational criteria reduces radiation risks overall. (author)

  5. Fundus Findings in Wernicke Encephalopathy

    Directory of Open Access Journals (Sweden)

    Tal Serlin

    2017-07-01

    Full Text Available Wernicke encephalopathy (WE is an acute neuropsychiatric syndrome resulting from thiamine (vitamin B1 deficiency, classically characterized by the triad of ophthalmoplegia, confusion, and ataxia. While commonly associated with chronic alcoholism, WE may also occur in the setting of poor nutrition or absorption. We present a 37-year-old woman who underwent laparoscopic sleeve gastrectomy and presented with visual disturbance with bilateral horizontal nystagmus, confusion, and postural imbalance. Fundus examination revealed bilateral optic disc edema with a retinal hemorrhage in the left eye. Metabolic workup demonstrated thiamine deficiency. Her symptoms resolved after thiamine treatment. This case raises the awareness of the possibility of posterior segment findings in WE, which are underreported in WE.

  6. FUNDUS AUTOFLUORESCENCE LIFETIMES AND CENTRAL SEROUS CHORIORETINOPATHY.

    Science.gov (United States)

    Dysli, Chantal; Berger, Lieselotte; Wolf, Sebastian; Zinkernagel, Martin S

    2017-11-01

    To quantify retinal fluorescence lifetimes in patients with central serous chorioretinopathy (CSC) and to identify disease specific lifetime characteristics over the course of disease. Forty-seven participants were included in this study. Patients with central serous chorioretinopathy were imaged with fundus photography, fundus autofluorescence, optical coherence tomography, and fluorescence lifetime imaging ophthalmoscopy (FLIO) and compared with age-matched controls. Retinal autofluorescence was excited using a 473-nm blue laser light and emitted fluorescence light was detected in 2 distinct wavelengths channels (498-560 nm and 560-720 nm). Clinical features, mean retinal autofluorescence lifetimes, autofluorescence intensity, and corresponding optical coherence tomography (OCT) images were further analyzed. Thirty-five central serous chorioretinopathy patients with a mean visual acuity of 78 ETDRS letters (range, 50-90; mean Snellen equivalent: 20/32) and 12 age-matched controls were included. In the acute stage of central serous chorioretinopathy, retinal fluorescence lifetimes were shortened by 15% and 17% in the respective wavelength channels. Multiple linear regression analysis showed that fluorescence lifetimes were significantly influenced by the disease duration (P autofluorescence lifetimes, particularly in eyes with retinal pigment epithelial atrophy, were associated with poor visual acuity. This study establishes that autofluorescence lifetime changes occurring in central serous chorioretinopathy exhibit explicit patterns which can be used to estimate perturbations of the outer retinal layers with a high degree of statistical significance.

  7. Strategies in digital marketing

    OpenAIRE

    Robert DRAGOMIR; Mihai ANDRONIE

    2017-01-01

    The present paper deals with digital marketing. The approach into discussion is the strategies met with the concept mentioned above. Within the actual socio-economic context, the electronic equipments offer on one hand new and innovative methods for products promoting and, on the other hand new challenges for the consumers. Thus, we analysed different and major types of strategies, which have a great impact on the digital marketing.

  8. The left hand second to fourth digit ratio (2D:4D) is not related to any physical fitness component in adolescent girls.

    Science.gov (United States)

    Peeters, Maarten W; Van Aken, Katrijn; Claessens, Albrecht L

    2013-01-01

    The second to fourth-digit-ratio (2D:4D), a putative marker of prenatal androgen action and a sexually dimorphic trait, has been suggested to be related with fitness and sports performance, although results are not univocal. Most studies however focus on a single aspect of physical fitness or one sports discipline. In this study the 2D:4D ratio of 178 adolescent girls (age 13.5-18 y) was measured on X-rays of the left hand. The relation between 2D:4D digit ratio and multiple aspects of physical fitness (balance, speed of limb movement, flexibility, explosive strength, static strength, trunk strength, functional strength, running speed/agility, and endurance) was studied by correlation analyses and stepwise multiple regression. For comparison the relation between these physical fitness components and a selected number of objectively measured anthropometric traits (stature, mass, BMI, somatotype components and the Bayer & Bailey androgyny index) are presented alongside the results of 2D:4D digit ratio. Left hand 2D:4D digit ratio (0.925±0.019) was not significantly correlated with any of the physical fitness components nor any of the anthropometric variables included in the present study. 2D:4D did not enter the multiple stepwise regression for any of the physical fitness components in which other anthropometric traits explained between 9.2% (flexibility) and 33.9% (static strength) of variance. Unlike other anthropometric traits the 2D:4D digit ratio does not seem to be related to any physical fitness component in adolescent girls and therefore most likely should not be considered in talent detection programs for sporting ability in girls.

  9. Managing Documentary Collections Through Digitization

    OpenAIRE

    Deegan, Marylin

    2001-01-01

    Digital collection development is part of a broader perspective on collection development, and generally needs to be assessed using the same criteria. However, there is a difference between reviewing collections already held by the institution with digitization in mind, and choosing to acquire digital materials from elsewhere. In-house holdings have been initially acquired or retained because they are perceived to have some value to the community served by the library, and therefore theoretic...

  10. Linearization of weak hand holds in Russian Sign Language

    NARCIS (Netherlands)

    Kimmelman, V.

    2017-01-01

    Russian Sign Language (RSL) makes use of constructions involving manual simultaneity, in particular, weak hand holds, where one hand is being held in the location and configuration of a sign, while the other simultaneously produces one sign or a sequence of several signs. In this paper, I argue that

  11. [Evaluation of fundus autofluorescence in hereditary retinal diseases using Heidelberg Retina Angiograph2].

    Science.gov (United States)

    Côco, Monique; Baba, Natalia Tamie; Sallum, Juliana Maria Ferraz

    2007-01-01

    To define characteristics of the fundus autofluorescence examination, verifying usefulness in the diagnosis and care of hereditary retinal diseases. 28 patients, adults, divided equally into four groups with diagnoses of Stargardt macular dystrophy, cone dystrophy, retinitis pigmentosa and healthy volunteers for the establishment of the normality pattern. An average of nine images with the filter for fluorescein angiography was obtained for the formation of the image autofluorescence using Heidelberg Retina Angiograph2. The images of each group of patients were analyzed to verify common characteristics. The fundus autofluorescence of healthy volunteers showed the foveal area darker than the surrounding retina. The images of Stargardt macular dystrophy, in general, presented an oval central lesion, with reduced autofluorescence. The main alterations of the autofluorescence in patients with cone dystrophy were reduced foveal autofluorescence with a parafoveal ring of increased autofluorescence. In general, the images of retinitis pigmentosa showed outlying pigments with reduced autofluorescence, and of the foveal area, in some cases disorganization or reduced autofluorescence. The study showed the existence of patterns of fundus autofluorescence in the hereditary retinal diseases that allow the diagnosis and better interpretation of the pathogenesis of these diseases.

  12. Reliability and reproducibility of disc-foveal angle measurements by non-mydriatic fundus photography.

    Science.gov (United States)

    Le Jeune, Caroline; Chebli, Fayçal; Leon, Lorette; Anthoine, Emmanuelle; Weber, Michel; Péchereau, Alain; Lebranchu, Pierre

    2018-01-01

    Abnormal torsion could be associated with cyclovertical strabismus, but torsion measurements are not reliable in children. To assess an objective fundus torsion evaluation in a paediatric population, we used Non-Mydriatic Fundus photography (NMFP) in healthy and cyclovertical strabismus patients to evaluate the disc-foveal angle over time and observers. We used a retrospective set of NMFP including 24 A or V-pattern strabismus and 27 age-matched normal children (mean age 6.4 and 6.7 years respectively), taken during 2 distinct follow-up consultations (separated by 251 and 479 days respectively). Each disc-foveal angle measurement (from which the ocular torsion can be assessed) was performed by 5 different observers, using graphical software and based on reproducible fundus anatomical marks. Statistical analysis was performed with a multivariate ANOVA using group, time and observers as factors, in addition to intraclass coefficient correlation (ICC) to assess measurement reproducibility. A significant difference of disc-foveal angle measures was observed between groups (p0,97). Abnormal amount of objective torsion could be associated with alphabet-pattern strabismus. Disc-foveal angle evaluation by NMFP in a children population appears as a non-invasive, reliable and reproducible method.

  13. Efficacy of hand held, inexpensive UV light sources on Acanthamoeba, causative organism in amoebic keratitis

    Directory of Open Access Journals (Sweden)

    Ivan Cometa

    2010-01-01

    Full Text Available Ivan Cometa1, Andrew Rogerson1, Scott Schatz21Department of Biology, California State University Fresno, Fresno, CA, USA; 2Arizona College of Optometry, Midwestern University, Glendale, AZ, USAAbstract: Multipurpose lens cleaning solutions (MPS fail to consistently kill or inactivate Acanthamoeba cysts and UV irradiation, while effective at high doses, can damage contact lenses. The present study considered synergy of action between MPS and hand-held inexpensive (ie, relatively weak UV irradiation units. Regardless of disinfection method recently formed cysts (<10 days were far more susceptible to treatment than mature cysts (>14 days. This has important implications for future protocols on testing methods for killing amoebae. The study also showed that cysts of different strains (two tested, FLA2 and P120 are variable in their response to MPS, presumably reflecting differences in cyst wall structure and thus permeability to the disinfectant. On the other hand, the effect of UV irradiation was not wall structure dependent. A 6-hour treatment with MPS alone killed trophic amoebae but failed to kill any mature cysts. Cysts of strain FLA2 were killed after 24 hours with MPS but cysts of strain P120 survived. UV irradiation with the larger 4 W unit killed all cysts after 7 minutes and was more effective than the smaller battery-powered unit (after 10 minutes about 50% of cysts were killed. When the larger unit was used with the MPS disinfection, all trophozoites were killed using UV for 3 minutes and MPS for 1 hour. The resistant P120 cysts remained a challenge but a 2- to 4-minute UV treatment followed by MPS for 3 or 6 hours reduced mature cyst survival by about 50%. The small unit in combination with MPS was less effective but did reduce the time required to kill trophic amoebae in MPS (6 hours MPS alone versus 3 hours MPS with a 1-minute UV treatment. In short, inexpensive UV units do enhance MPS disinfection and future lens cleaning systems

  14. Matching fundus photographs of classmates. An informal competition to promote learning and practice of direct ophthalmoscopy among medical students.

    Science.gov (United States)

    Krohn, Jørgen; Kjersem, Bård; Høvding, Gunnar

    2014-05-01

    To present a new approach for teaching direct ophthalmoscopy to medical students. At the University of Bergen, four consecutive classes of fourth-year medical students complete a required 9-week ophthalmology course every year. In the present project, one fundus photograph was taken of each student. The photographs were randomly numbered, printed on A4 glossy photo paper, and displayed on the classroom wall. Each student was given a form to fill in the fellow students' names matching the number of the fundus photographs. They were encouraged to practise direct ophthalmoscopy on their classmates outside formal teaching hours. At the end of the course, they returned the filled-in forms, and those with the highest number of correct matches between the fundus photographs and fellow students received a reward. Between 2011 and 2013, 239 students completed their ophthalmology course. Of these, 220 students (92%) voluntarily participated in the project. The mean score was 70% correct matches between fundus photographs and fellow students (range 7 - 100%). The students' course evaluations were overall positive. We recommend the use of peer fundus photographs in the context of a learning competition as a simple, inexpensive, and effective way to improve teaching of direct ophthalmoscopy.

  15. Trans-palpebral illumination: an approach for wide-angle fundus photography without the need for pupil dilation

    OpenAIRE

    Toslak, Devrim; Thapa, Damber; Chen, Yanjun; Erol, Muhammet Kazim; Paul Chan, R. V.; Yao, Xincheng

    2016-01-01

    It is technically difficult to construct wide-angle fundus imaging devices due to the complexity of conventional transpupillary illumination and imaging mechanisms. We report here a new method, i.e., trans-palpebral illumination, for wide-angle fundus photography without the need for pupil dilation. By constructing a smartphone-based prototype imaging device, we demonstrated a 152° view in a single-shot image. The unique combination of low-cost smartphone design and automatic illumination opt...

  16. Fundus Autofluorescence Imaging in an Ocular Screening Program

    Directory of Open Access Journals (Sweden)

    A. M. Kolomeyer

    2012-01-01

    Full Text Available Purpose. To describe integration of fundus autofluorescence (FAF imaging into an ocular screening program. Methods. Fifty consecutive screening participants were included in this prospective pilot imaging study. Color and FAF (530/640 nm exciter/barrier filters images were obtained with a 15.1MP Canon nonmydriatic hybrid camera. A clinician evaluated the images on site to determine need for referral. Visual acuity (VA, intraocular pressure (IOP, and ocular pathology detected by color fundus and FAF imaging modalities were recorded. Results. Mean ± SD age was 47.4 ± 17.3 years. Fifty-two percent were female and 58% African American. Twenty-seven percent had a comprehensive ocular examination within the past year. Mean VA was 20/39 in the right eye and 20/40 in the left eye. Mean IOP was 15 mmHg bilaterally. Positive color and/or FAF findings were identified in nine (18% individuals with diabetic retinopathy or macular edema (n=4, focal RPE defects (n=2, age-related macular degeneration (n=1, central serous retinopathy (n=1, and ocular trauma (n=1. Conclusions. FAF was successfully integrated in our ocular screening program and aided in the identification of ocular pathology. Larger studies examining the utility of this technology in screening programs may be warranted.

  17. Fundus autofluorescence imaging in an ocular screening program.

    Science.gov (United States)

    Kolomeyer, A M; Nayak, N V; Szirth, B C; Khouri, A S

    2012-01-01

    Purpose. To describe integration of fundus autofluorescence (FAF) imaging into an ocular screening program. Methods. Fifty consecutive screening participants were included in this prospective pilot imaging study. Color and FAF (530/640 nm exciter/barrier filters) images were obtained with a 15.1MP Canon nonmydriatic hybrid camera. A clinician evaluated the images on site to determine need for referral. Visual acuity (VA), intraocular pressure (IOP), and ocular pathology detected by color fundus and FAF imaging modalities were recorded. Results. Mean ± SD age was 47.4 ± 17.3 years. Fifty-two percent were female and 58% African American. Twenty-seven percent had a comprehensive ocular examination within the past year. Mean VA was 20/39 in the right eye and 20/40 in the left eye. Mean IOP was 15 mmHg bilaterally. Positive color and/or FAF findings were identified in nine (18%) individuals with diabetic retinopathy or macular edema (n = 4), focal RPE defects (n = 2), age-related macular degeneration (n = 1), central serous retinopathy (n = 1), and ocular trauma (n = 1). Conclusions. FAF was successfully integrated in our ocular screening program and aided in the identification of ocular pathology. Larger studies examining the utility of this technology in screening programs may be warranted.

  18. Automated segmentation of geographic atrophy of the retinal epithelium via random forests in AREDS color fundus images☆

    Science.gov (United States)

    Feeny, Albert K.; Tadarati, Mongkol; Freund, David E.; Bressler, Neil M.; Burlina, Philippe

    2015-01-01

    Background Age-related macular degeneration (AMD), left untreated, is the leading cause of vision loss in people older than 55. Severe central vision loss occurs in the advanced stage of the disease, characterized by either the in growth of choroidal neovascularization (CNV), termed the “wet” form, or by geographic atrophy (GA) of the retinal pigment epithelium (RPE) involving the center of the macula, termed the “dry” form. Tracking the change in GA area over time is important since it allows for the characterization of the effectiveness of GA treatments. Tracking GA evolution can be achieved by physicians performing manual delineation of GA area on retinal fundus images. However, manual GA delineation is time-consuming and subject to inter-and intra-observer variability. Methods We have developed a fully automated GA segmentation algorithm in color fundus images that uses a supervised machine learning approach employing a random forest classifier. This algorithm is developed and tested using a dataset of images from the NIH-sponsored Age Related Eye Disease Study (AREDS). GA segmentation output was compared against a manual delineation by a retina specialist. Results Using 143 color fundus images from 55 different patient eyes, our algorithm achieved PPV of 0.82±0.19, and NPV of 0:95±0.07. Discussion This is the first study, to our knowledge, applying machine learning methods to GA segmentation on color fundus images and using AREDS imagery for testing. These preliminary results show promising evidence that machine learning methods may have utility in automated characterization of GA from color fundus images. PMID:26318113

  19. Automated segmentation of geographic atrophy of the retinal epithelium via random forests in AREDS color fundus images.

    Science.gov (United States)

    Feeny, Albert K; Tadarati, Mongkol; Freund, David E; Bressler, Neil M; Burlina, Philippe

    2015-10-01

    Age-related macular degeneration (AMD), left untreated, is the leading cause of vision loss in people older than 55. Severe central vision loss occurs in the advanced stage of the disease, characterized by either the in growth of choroidal neovascularization (CNV), termed the "wet" form, or by geographic atrophy (GA) of the retinal pigment epithelium (RPE) involving the center of the macula, termed the "dry" form. Tracking the change in GA area over time is important since it allows for the characterization of the effectiveness of GA treatments. Tracking GA evolution can be achieved by physicians performing manual delineation of GA area on retinal fundus images. However, manual GA delineation is time-consuming and subject to inter-and intra-observer variability. We have developed a fully automated GA segmentation algorithm in color fundus images that uses a supervised machine learning approach employing a random forest classifier. This algorithm is developed and tested using a dataset of images from the NIH-sponsored Age Related Eye Disease Study (AREDS). GA segmentation output was compared against a manual delineation by a retina specialist. Using 143 color fundus images from 55 different patient eyes, our algorithm achieved PPV of 0.82±0.19, and NPV of 0:95±0.07. This is the first study, to our knowledge, applying machine learning methods to GA segmentation on color fundus images and using AREDS imagery for testing. These preliminary results show promising evidence that machine learning methods may have utility in automated characterization of GA from color fundus images. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. An automated and robust image processing algorithm for glaucoma diagnosis from fundus images using novel blood vessel tracking and bend point detection.

    Science.gov (United States)

    M, Soorya; Issac, Ashish; Dutta, Malay Kishore

    2018-02-01

    Glaucoma is an ocular disease which can cause irreversible blindness. The disease is currently identified using specialized equipment operated by optometrists manually. The proposed work aims to provide an efficient imaging solution which can help in automating the process of Glaucoma diagnosis using computer vision techniques from digital fundus images. The proposed method segments the optic disc using a geometrical feature based strategic framework which improves the detection accuracy and makes the algorithm invariant to illumination and noise. Corner thresholding and point contour joining based novel methods are proposed to construct smooth contours of Optic Disc. Based on a clinical approach as used by ophthalmologist, the proposed algorithm tracks blood vessels inside the disc region and identifies the points at which first vessel bend from the optic disc boundary and connects them to obtain the contours of Optic Cup. The proposed method has been compared with the ground truth marked by the medical experts and the similarity parameters, used to determine the performance of the proposed method, have yield a high similarity of segmentation. The proposed method has achieved a macro-averaged f-score of 0.9485 and accuracy of 97.01% in correctly classifying fundus images. The proposed method is clinically significant and can be used for Glaucoma screening over a large population which will work in a real time. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Automatic digitization of SMA data

    Science.gov (United States)

    Väänänen, Mika; Tanskanen, Eija

    2017-04-01

    In the 1970's and 1980's the Scandinavian Magnetometer Array produced large amounts of excellent data from over 30 stations In Norway, Sweden and Finland. 620 film reels and 20 kilometers of film have been preserved and the longest time series produced in the campaign span almost uninterrupted for five years, but the data has never seen widespread use due to the choice of medium. Film is a difficult medium to digitize efficiently. Previously events of interest were searched for by hand and digitization was done by projecting the film on paper and plotting it by hand. We propose a method of automatically digitizing geomagnetic data stored on film and extracting the numerical values from the digitized data. The automatic digitization process helps in preserving old, valuable data that might otherwise go unused.

  2. The left hand second to fourth digit ratio (2D:4D is not related to any physical fitness component in adolescent girls.

    Directory of Open Access Journals (Sweden)

    Maarten W Peeters

    Full Text Available INTRODUCTION: The second to fourth-digit-ratio (2D:4D, a putative marker of prenatal androgen action and a sexually dimorphic trait, has been suggested to be related with fitness and sports performance, although results are not univocal. Most studies however focus on a single aspect of physical fitness or one sports discipline. METHODS: In this study the 2D:4D ratio of 178 adolescent girls (age 13.5-18 y was measured on X-rays of the left hand. The relation between 2D:4D digit ratio and multiple aspects of physical fitness (balance, speed of limb movement, flexibility, explosive strength, static strength, trunk strength, functional strength, running speed/agility, and endurance was studied by correlation analyses and stepwise multiple regression. For comparison the relation between these physical fitness components and a selected number of objectively measured anthropometric traits (stature, mass, BMI, somatotype components and the Bayer & Bailey androgyny index are presented alongside the results of 2D:4D digit ratio. RESULTS: Left hand 2D:4D digit ratio (0.925±0.019 was not significantly correlated with any of the physical fitness components nor any of the anthropometric variables included in the present study. 2D:4D did not enter the multiple stepwise regression for any of the physical fitness components in which other anthropometric traits explained between 9.2% (flexibility and 33.9% (static strength of variance. CONCLUSION: Unlike other anthropometric traits the 2D:4D digit ratio does not seem to be related to any physical fitness component in adolescent girls and therefore most likely should not be considered in talent detection programs for sporting ability in girls.

  3. PBL, Hands-On/ Digital resources in Geology, (Teaching/ Learning)

    Science.gov (United States)

    Soares, Rosa; Santos, Cátia; Carvalho, Sara

    2015-04-01

    several instruments such as small questionnaires (Hot Potatoes), Gowin V, scientific report, a grid to evaluate group work and a grid to evaluate the development of competencies. This study intended to evaluate the success of a PBL intervention program when trying to improve students' outcomes. The positive impact obtained allowed us to advance some conclusions and instructional implications regarding teaching Rock Cycle through PBL and different digital and hands-on resources, obtained, especially in the students' questionnaires and Gowin V, allowed us to verify that students did learn about Rock Cycle and developed collaborative work skills.

  4. Fundus autofluorescence patterns in primary intraocular lymphoma.

    Science.gov (United States)

    Casady, Megan; Faia, Lisa; Nazemzadeh, Maryam; Nussenblatt, Robert; Chan, Chi-Chao; Sen, H Nida

    2014-02-01

    To evaluate fundus autofluorescence (FAF) patterns in patients with primary intraocular (vitreoretinal) lymphoma. Records of all patients with primary intraocular lymphoma who underwent FAF imaging at the National Eye Institute were reviewed. Fundus autofluorescence patterns were evaluated with respect to clinical disease status and the findings on fluorescein angiography and spectral-domain optical coherence tomography. There were 18 eyes (10 patients) with primary intraocular lymphoma that underwent FAF imaging. Abnormal autofluorescence in the form of granular hyperautofluorescence and hypoautofluorescence was seen in 11 eyes (61%), and blockage by mass lesion was seen in 2 eyes (11%). All eyes with granular pattern on FAF had active primary intraocular lymphoma at the time of imaging, but there were 5 eyes with unremarkable FAF, which were found to have active lymphoma. The most common pattern on fluorescein angiography was hypofluorescent round spots with a "leopard spot" appearance (43%). These hypofluorescent spots on fluorescein angiography correlated with hyperautofluorescent spots on FAF in 5 eyes (36%) (inversion of FAF). Nodular hyperreflective spots at the level of retinal pigment epithelium on optical coherence tomography were noted in 43% of eyes. The hyperautofluorescent spots on FAF correlated with nodular hyperreflective spots on optical coherence tomography in 6 eyes (43%). Granularity on FAF was associated with active lymphoma in majority of the cases. An inversion of FAF (hyperautofluorescent spots on FAF corresponding to hypofluorescent spots on fluorescein angiography) was observed in less than half of the eyes.

  5. Forest Inventory with Terrestrial LiDAR: A Comparison of Static and Hand-Held Mobile Laser Scanning

    Directory of Open Access Journals (Sweden)

    Sébastien Bauwens

    2016-06-01

    Full Text Available The application of static terrestrial laser scanning (TLS in forest inventories is becoming more effective. Nevertheless, the occlusion effect is still limiting the processing efficiency to extract forest attributes. The use of a mobile laser scanner (MLS would reduce this occlusion. In this study, we assessed and compared a hand-held mobile laser scanner (HMLS with two TLS approaches (single scan: SS, and multi scan: MS for the estimation of several forest parameters in a wide range of forest types and structures. We found that SS is competitive to extract the ground surface of forest plots, while MS gives the best result to describe the upper part of the canopy. The whole cross-section at 1.3 m height is scanned for 91% of the trees (DBH > 10 cm with the HMLS leading to the best results for DBH estimates (bias of −0.08 cm and RMSE of 1.11 cm, compared to no fully-scanned trees for SS and 42% fully-scanned trees for MS. Irregularities, such as bark roughness and non-circular cross-section may explain the negative bias encountered for all of the scanning approaches. The success of using MLS in forests will allow for 3D structure acquisition on a larger scale and in a time-efficient manner.

  6. Eye and hand motor interactions with the Symbol Digit Modalities Test in early multiple sclerosis.

    Science.gov (United States)

    Nygaard, Gro O; de Rodez Benavent, Sigrid A; Harbo, Hanne F; Laeng, Bruno; Sowa, Piotr; Damangir, Soheil; Bernhard Nilsen, Kristian; Etholm, Lars; Tønnesen, Siren; Kerty, Emilia; Drolsum, Liv; Inge Landrø, Nils; Celius, Elisabeth G

    2015-11-01

    Eye and hand motor dysfunction may be present early in the disease course of relapsing-remitting multiple sclerosis (RRMS), and can affect the results on visual and written cognitive tests. We aimed to test for differences in saccadic initiation time (SI time) between RRMS patients and healthy controls, and whether SI time and hand motor speed interacted with the written version of the Symbol Digit Modalities Test (wSDMT). Patients with RRMS (N = 44, age 35.1 ± 7.3 years), time since diagnosis < 3 years and matched controls (N = 41, age 33.2 ± 6.8 years) were examined with ophthalmological, neurological and neuropsychological tests, as well as structural MRI (white matter lesion load (WMLL) and brainstem lesions), visual evoked potentials (VEP) and eye-tracker examinations of saccades. SI time was longer in RRMS than controls (p < 0.05). SI time was not related to the Paced Auditory Serial Addition Test (PASAT), WMLL or to the presence of brainstem lesions. 9 hole peg test (9HP) correlated significantly with WMLL (r = 0.58, p < 0.01). Both SI time and 9HP correlated negatively with the results of wSDMT (r = -0.32, p < 0.05, r = -0.47, p < 0.01), but none correlated with the results of PASAT. RRMS patients have an increased SI time compared to controls. Cognitive tests results, exemplified by the wSDMT, may be confounded by eye and hand motor function. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  7. Interpretations of Fundus Autofluorescence from Studies of the Bisretinoids of the Retina

    OpenAIRE

    Sparrow, Janet R.; Yoon, Kee Dong; Wu, Yalin; Yamamoto, Kazunori

    2010-01-01

    Elevated fundus autofluorescence signals can reflect enhanced lipofuscin in RPE cells, augmented fluorescence due to photooxidation, and/or excess bisretinoid fluorophores in photoreceptor cells due to mishandling of vitamin A aldehyde by dysfunctional cells.

  8. Development and pilot testing of HEXORR: Hand EXOskeleton Rehabilitation Robot

    Directory of Open Access Journals (Sweden)

    Godfrey Sasha B

    2010-07-01

    Full Text Available Abstract Background Following acute therapeutic interventions, the majority of stroke survivors are left with a poorly functioning hemiparetic hand. Rehabilitation robotics has shown promise in providing patients with intensive therapy leading to functional gains. Because of the hand's crucial role in performing activities of daily living, attention to hand therapy has recently increased. Methods This paper introduces a newly developed Hand Exoskeleton Rehabilitation Robot (HEXORR. This device has been designed to provide full range of motion (ROM for all of the hand's digits. The thumb actuator allows for variable thumb plane of motion to incorporate different degrees of extension/flexion and abduction/adduction. Compensation algorithms have been developed to improve the exoskeleton's backdrivability by counteracting gravity, stiction and kinetic friction. We have also designed a force assistance mode that provides extension assistance based on each individual's needs. A pilot study was conducted on 9 unimpaired and 5 chronic stroke subjects to investigate the device's ability to allow physiologically accurate hand movements throughout the full ROM. The study also tested the efficacy of the force assistance mode with the goal of increasing stroke subjects' active ROM while still requiring active extension torque on the part of the subject. Results For 12 of the hand digits'15 joints in neurologically normal subjects, there were no significant ROM differences (P > 0.05 between active movements performed inside and outside of HEXORR. Interjoint coordination was examined in the 1st and 3rd digits, and no differences were found between inside and outside of the device (P > 0.05. Stroke subjects were capable of performing free hand movements inside of the exoskeleton and the force assistance mode was successful in increasing active ROM by 43 ± 5% (P Conclusions Our pilot study shows that this device is capable of moving the hand's digits through

  9. Development and pilot testing of HEXORR: Hand EXOskeleton Rehabilitation Robot

    Science.gov (United States)

    2010-01-01

    Background Following acute therapeutic interventions, the majority of stroke survivors are left with a poorly functioning hemiparetic hand. Rehabilitation robotics has shown promise in providing patients with intensive therapy leading to functional gains. Because of the hand's crucial role in performing activities of daily living, attention to hand therapy has recently increased. Methods This paper introduces a newly developed Hand Exoskeleton Rehabilitation Robot (HEXORR). This device has been designed to provide full range of motion (ROM) for all of the hand's digits. The thumb actuator allows for variable thumb plane of motion to incorporate different degrees of extension/flexion and abduction/adduction. Compensation algorithms have been developed to improve the exoskeleton's backdrivability by counteracting gravity, stiction and kinetic friction. We have also designed a force assistance mode that provides extension assistance based on each individual's needs. A pilot study was conducted on 9 unimpaired and 5 chronic stroke subjects to investigate the device's ability to allow physiologically accurate hand movements throughout the full ROM. The study also tested the efficacy of the force assistance mode with the goal of increasing stroke subjects' active ROM while still requiring active extension torque on the part of the subject. Results For 12 of the hand digits'15 joints in neurologically normal subjects, there were no significant ROM differences (P > 0.05) between active movements performed inside and outside of HEXORR. Interjoint coordination was examined in the 1st and 3rd digits, and no differences were found between inside and outside of the device (P > 0.05). Stroke subjects were capable of performing free hand movements inside of the exoskeleton and the force assistance mode was successful in increasing active ROM by 43 ± 5% (P < 0.001) and 24 ± 6% (P = 0.041) for the fingers and thumb, respectively. Conclusions Our pilot study shows that this device

  10. Retro-mode imaging and fundus autofluorescence with scanning laser ophthalmoscope of retinal dystrophies

    Directory of Open Access Journals (Sweden)

    Maurizio Battaglia

    2012-05-01

    Full Text Available Abstract Background Retinal dystrophies display a considerably wide range of phenotypic variability, which can make diagnosis and clinical staging difficult. The aim of the study is to analyze the contribution of retro-mode imaging (RMI and fundus autofluorescence (FAF to the characterization of retinal dystrophies. Methods Eighteen consecutive patients affected by retinal dystrophies underwent a complete ophthalmological examination, including best corrected visual acuity with ETDRS charts, blue-light fundus autofluorescence, (BL-FAF, near-infrared fundus autofluorescence (NIR-FAF, and RMI. The primary outcome was the identification of abnormal patterns on RMI. The secondary outcome was the correlation with the findings on BL-FAF and NIR-FAF. Results Overall, the main feature of RMI is represented by a pseudo-3D pattern of all the lesions at the posterior pole. More specifically, any accumulation of material within the retina appears as an area of elevation of different shape and size, displaying irregular and darker borders. No precise correlations between RMI, BL-AF, and NIR-AF imaging was found. Conclusions RMI and FAF appear to be useful tools for characterizing retinal dystrophies. Non-invasive diagnostic tools may yield additional information on the clinical setting and the monitoring of the patients.

  11. The Relationship Between Digit Independence and Digital Sesamoids in Humans and a Proposal of a New Digital Sesamoid Evolutionary Hypothesis.

    Science.gov (United States)

    Yammine, Kaissar

    2018-01-03

    Digital sesamoids are found in the metapodial-phalangeal joints of most mammals and quadrupedal tetrapods, yet their functional significance is still unclear. During primate evolution, a slight decline in their frequency has been associated with brachiation in gibbons, followed by a quasi-complete absence in orangutans then a slight resurgence occurred in gorillas and chimpanzees. Simultaneously, forearm muscles showed a progressive division in hominoid evolution towards a more "individualistic" musculature yielding more mobility and independence to some fingers. In humans, sesamoids are consistently observed in thumbs and big toes and frequently in other hypermobile digits such as the index and little fingers. Using a simple mathematical equation, this paper attempted to quantify a presumed association between hypermobile fingers and sesamoid frequency and distribution in humans. To this, an anatomic definition of digital independence has been formulated which includes three variables; (1) number and (2) frequency of independent flexor/extensor forearm muscles destined to a single finger, (3) and number of free/absent webspace. Results of previous meta-analyses and means of big sample studies were used to evaluate the frequency of such muscles. The expected values obtained via this model were found to be very close to the observed (published) values of the ossified sesamoids in human hands, and that in terms of frequency and distribution. The findings in humans showed a quasi-linear association between the degree of mobility and sesamoid frequency. The more the number of independent muscles destined to a finger, the more its metacarpo-phalangeal joint is likely to bear sesamoids. Based on our results and on a new analysis of primates' forearm/hand muscles and sesamoid evolution, a new hypothesis is proposed to answer two questions; the evolution of digital sesamoid frequency in primates and its sesamoid distribution in human digits. It claims that the number

  12. Maximal isometric muscle strength values obtained By hand-held dynamometry in children between 6 and 15 years of age.

    Science.gov (United States)

    Escobar, Raul G; Munoz, Karin T; Dominguez, Angelica; Banados, Pamela; Bravo, Maria J

    2017-01-01

    In this study we aimed to determine the maximal isometric muscle strength of a healthy, normal-weight, pediatric population between 6 and 15 years of age using hand-held dynamometry to establish strength reference values. The secondary objective was determining the relationship between strength and anthropometric parameters. Four hundred normal-weight Chilean children, split into 10 age groups, separated by 1-year intervals, were evaluated. Each age group included between 35 and 55 children. The strength values increased with increasing age and weight, with a correlation of 0.83 for age and 0.82 for weight. The results were similar to those reported in previous studies regarding the relationships among strength, age, and anthropometric parameters, but the reported strength differed. These results provide normal strength parameters for healthy and normal-weight Chilean children between 6 and 15 years of age and highlight the relevance of ethnicity in defining reference values for muscle strength in a pediatric population. Muscle Nerve 55: 16-22, 2017. © 2016 Wiley Periodicals, Inc.

  13. Segmentasi Pembuluh Darah Retina Pada Citra Fundus Menggunakan Gradient Based Adaptive Thresholding Dan Region Growing

    Directory of Open Access Journals (Sweden)

    Deni Sutaji

    2016-07-01

    Full Text Available AbstrakSegmentasi pembuluh darah pada citra fundus retina menjadi hal yang substansial dalam dunia kedokteran, karena dapat digunakan untuk mendeteksi penyakit, seperti: diabetic retinopathy, hypertension, dan cardiovascular. Dokter membutuhkan waktu sekitar dua jam untuk mendeteksi pembuluh darah retina, sehingga diperlukan metode yang dapat membantu screening agar lebih cepat.Penelitian sebelumnya mampu melakukan segmentasi pembuluh darah yang sensitif terhadap variasi ukuran lebar pembuluh darah namun masih terjadi over-segmentasi pada area patologi. Oleh karena itu, penelitian ini bertujuan untuk mengembangkan metode segmentasi pembuluh darah pada citra fundus retina yang dapat mengurangi over-segmentasi pada area patologi menggunakan Gradient Based Adaptive Thresholding dan Region Growing.Metode yang diusulkan terdiri dari 3 tahap, yaitu segmentasi pembuluh darah utama, deteksi area patologi dan segmentasi pembuluh darah tipis. Tahap segmentasi pembuluh darah utama menggunakan high-pass filtering dan tophat reconstruction pada kanal hijau citra yang sudah diperbaiki kontrasnya sehingga lebih jelas perbedaan antara pembuluh darah dan background. Tahap deteksi area patologi menggunakan metode Gradient Based Adaptive Thresholding. Tahap segmentasi pembuluh darah tipis menggunakan Region Growing berdasarkan informasi label pembuluh darah utama dan label area patologi. Hasil segmentasi pembuluh darah utama dan pembuluh darah tipis kemudian digabungkan sehingga menjadi keluaran sistem berupa citra biner pembuluh darah. Berdasarkan hasil uji coba, metode ini mampu melakukan segmentasi pembuluh darah retina dengan baik pada citra fundus DRIVE, yaitu dengan akurasi rata-rata 95.25% dan nilai Area Under Curve (AUC pada kurva Relative Operating Characteristic (ROC sebesar 74.28%.                           Kata Kunci: citra fundus retina, gradient based adaptive thresholding, patologi, pembuluh darah retina, region growing

  14. Analysis of visual appearance of retinal nerve fibers in high resolution fundus images: a study on normal subjects.

    Science.gov (United States)

    Kolar, Radim; Tornow, Ralf P; Laemmer, Robert; Odstrcilik, Jan; Mayer, Markus A; Gazarek, Jiri; Jan, Jiri; Kubena, Tomas; Cernosek, Pavel

    2013-01-01

    The retinal ganglion axons are an important part of the visual system, which can be directly observed by fundus camera. The layer they form together inside the retina is the retinal nerve fiber layer (RNFL). This paper describes results of a texture RNFL analysis in color fundus photographs and compares these results with quantitative measurement of RNFL thickness obtained from optical coherence tomography on normal subjects. It is shown that local mean value, standard deviation, and Shannon entropy extracted from the green and blue channel of fundus images are correlated with corresponding RNFL thickness. The linear correlation coefficients achieved values 0.694, 0.547, and 0.512 for respective features measured on 439 retinal positions in the peripapillary area from 23 eyes of 15 different normal subjects.

  15. Automation Study for Longhorn Army Ammunition Plant Hand Held Signal Flight Assembly, Rocket Barrel Assembly, 40 MM Signal, Final Packaging/Pack-Out, and Star Finishing

    Science.gov (United States)

    1990-03-01

    wood protectors in the HHS Rocket Barrel Assembly Operations. d) Use of hot melt sealant rather than lacquer on the end of the assembled Hand Held...4OL.UA8LYADHRlE CG411!cLVPAM-1 ~LW7m~I~o~c~c LCA ~TM18UX"Y.31nSRGU-11 STiIM ASSELYJMACE FINh1TZ1A1*4CWAJKRZAM’ WAOiNt rs~my" LOCATM1ED 0~7 LOCA1ED’ IWCM-1W...Moorfeed Fairview, PA Indianapolis, IN Voice Synthesis Module Square D Micro Chip Technology Palatine, IL Chandler, AZ 85224 Vacuum Unit Venturi’s

  16. Nitrergic Pathway Is the Main Contributing Mechanism in the Human Gastric Fundus Relaxation: An In Vitro Study.

    Directory of Open Access Journals (Sweden)

    Yang Won Min

    Full Text Available Human gastric fundus relaxation is mediated by intrinsic inhibitory pathway. We investigated the roles of nitrergic and purinergic pathways, two known inhibitory factors in gastric motility, on spontaneous and nerve-evoked contractions in human gastric fundus muscles.Gastric fundus muscle strips (12 circular and 13 longitudinal were obtained from patients without previous gastrointestinal motility disorder who underwent gastrectomy for stomach cancer. Using these specimens, we examined basal tone, peak, amplitude, and frequency of spontaneous contractions, and peak and nadir values under electrical field stimulation (EFS, 150 V, 0.3 ms, 10 Hz, 20 s. To examine responses to purinergic and nitrergic inhibition without cholinergic innervation, atropine (muscarinic antagonist, 1 μM, MRS2500 (a purinergic P2Y1 receptor antagonist, 1 μM, and N-nitro-L-arginine (L-NNA, a nitric oxide synthase inhibitor, 100 μM were added sequentially for spontaneous and electrically-stimulated contractions. Tetrodotoxin was used to confirm any neuronal involvement.In spontaneous contraction, L-NNA increased basal tone and peak in both muscle layers, while amplitude and frequency were unaffected. EFS (up to 10 Hz uniformly induced initial contraction and subsequent relaxation in a frequency-dependent manner. Atropine abolished initial on-contraction and induced only relaxation during EFS. While MRS2500 showed no additional influence, L-NNA reversed relaxation (p = 0.012 in circular muscle, and p = 0.006 in longitudinal muscle. Tetrodotoxin abolished any EFS-induced motor response.The relaxation of human gastric fundus muscle is reduced by nitrergic inhibition. Hence, nitrergic pathway appears to be the main mechanism for the human gastric fundus relaxation.

  17. Comparative study of the polaroid and digital non-mydriatic cameras in the detection of referrable diabetic retinopathy in Australia.

    Science.gov (United States)

    Phiri, R; Keeffe, J E; Harper, C A; Taylor, H R

    2006-08-01

    To show that the non-mydriatic retinal camera (NMRC) using polaroid film is as effective as the NMRC using digital imaging in detecting referrable retinopathy. A series of patients with diabetes attending the eye out-patients department at the Royal Victorian Eye and Ear Hospital had single-field non-mydriatic fundus photographs taken using first a digital and then a polaroid camera. Dilated 30 degrees seven-field stereo fundus photographs were then taken of each eye as the gold standard. The photographs were graded in a masked fashion. Retinopathy levels were defined using the simplified Wisconsin Grading system. We used the kappa statistics for inter-reader and intrareader agreement and the generalized linear model to derive the odds ratio. There were 196 participants giving 325 undilated retinal photographs. Of these participants 111 (57%) were males. The mean age of the patients was 68.8 years. There were 298 eyes with all three sets of photographs from 154 patients. The digital NMRC had a sensitivity of 86.2%[95% confidence interval (CI) 65.8, 95.3], whilst the polaroid NMRC had a sensitivity of 84.1% (95% CI 65.5, 93.7). The specificities of the two cameras were identical at 71.2% (95% CI 58.8, 81.1). There was no difference in the ability of the polaroid and digital camera to detect referrable retinopathy (odds ratio 1.06, 95% CI 0.80, 1.40, P = 0.68). This study suggests that non-mydriatic retinal photography using polaroid film is as effective as digital imaging in the detection of referrable retinopathy in countries such as the USA and Australia or others that use the same criterion for referral.

  18. Unusual optical coherence tomography and fundus autofluorescence findings of eclipse retinopathy

    Directory of Open Access Journals (Sweden)

    Kun-Hsien Li

    2012-01-01

    Full Text Available A 63-year-old female patient complained of dimness in the central field of vision in the left eye after viewing an annular partial eclipse without adequate eye protection on 22 July 2009. Fundoscopy showed a wrinkled macular surface. Fundus autofluorescence study revealed well-demarcated hyperautofluorescence at the fovea. Optical coherence tomography demonstrated tiny intraretinal cysts. Fluorescein angiography and indocyanine green angiography were unremarkable. Epimacular membrane developed in the following month with deteriorated vision. Vitrectomy, epiretinal membrane and internal limiting membrane peeling were performed. Vision was restored to 20/20 after the operation. Direct sun-gazing may damage the retinal structures resulting in macular inflammation and increased focal metabolism, which explains the hyperautofluorescence. It may also induce epimacular membrane. Fundus autofluorescence might represent a useful technique to detect subtle solar-induced injuries of the retina. The visual prognosis is favorable but prevention remains the mainstay of treatment. Public health education is mandatory in reducing visual morbidity.

  19. The hand of Homo naledi

    Science.gov (United States)

    Kivell, Tracy L.; Deane, Andrew S.; Tocheri, Matthew W.; Orr, Caley M.; Schmid, Peter; Hawks, John; Berger, Lee R.; Churchill, Steven E.

    2015-01-01

    A nearly complete right hand of an adult hominin was recovered from the Rising Star cave system, South Africa. Based on associated hominin material, the bones of this hand are attributed to Homo naledi. This hand reveals a long, robust thumb and derived wrist morphology that is shared with Neandertals and modern humans, and considered adaptive for intensified manual manipulation. However, the finger bones are longer and more curved than in most australopiths, indicating frequent use of the hand during life for strong grasping during locomotor climbing and suspension. These markedly curved digits in combination with an otherwise human-like wrist and palm indicate a significant degree of climbing, despite the derived nature of many aspects of the hand and other regions of the postcranial skeleton in H. naledi. PMID:26441219

  20. Analysis of Visual Appearance of Retinal Nerve Fibers in High Resolution Fundus Images: A Study on Normal Subjects

    Directory of Open Access Journals (Sweden)

    Radim Kolar

    2013-01-01

    Full Text Available The retinal ganglion axons are an important part of the visual system, which can be directly observed by fundus camera. The layer they form together inside the retina is the retinal nerve fiber layer (RNFL. This paper describes results of a texture RNFL analysis in color fundus photographs and compares these results with quantitative measurement of RNFL thickness obtained from optical coherence tomography on normal subjects. It is shown that local mean value, standard deviation, and Shannon entropy extracted from the green and blue channel of fundus images are correlated with corresponding RNFL thickness. The linear correlation coefficients achieved values 0.694, 0.547, and 0.512 for respective features measured on 439 retinal positions in the peripapillary area from 23 eyes of 15 different normal subjects.

  1. Digital Immigrants and Digital Natives: Learning Business Informatics at Higher Educational Level

    OpenAIRE

    Suša, Dalia

    2014-01-01

    Background: The term digital natives refer to those born since the 1980s and have been growing up surrounded by technology. On the other hand, digital immigrants are born before 1980s and learned how to use technology later in life. Objectives: Goal of the paper is to explore attitudes of digital native students on the course of Business Informatics at higher educational institutions (HEIs), and to compare them with attitudes of digital immigrants. Methods/Approach: The survey was conducted i...

  2. [Hand hygiene technique assessment using electronic equipment in 26 Hungarian healthcare institutions].

    Science.gov (United States)

    Lehotsky, Ákos; Morvai, Júlia; Szilágyi, László; Bánsághi, Száva; Benkó, Alíz; Haidegger, Tamás

    2017-07-01

    Hand hygiene is probably the most effective tool of nosocomial infection prevention, however, proper feedback and control is needed to develop the individual hand hygiene practice. Assessing the efficiency of modern education tools, and digital demonstration and verification equipment during their wide-range deployment. 1269 healthcare workers took part in a training organized by our team. The training included the assessment of the participants' hand hygiene technique to identify the most often missed areas. The hand hygiene technique was examined by a digital device. 33% of the participants disinfected their hands incorrectly. The most often missed sites are the fingertips (33% on the left hand, 37% on the right hand) and the thumbs (42% on the left hand, 32% on the right hand). The feedback has a fundamental role in the development of the hand hygiene technique. With the usage of electronic devices feedback can be provided efficiently and simply. Orv Hetil. 2017; 158(29): 1143-1148.

  3. Thickness related textural properties of retinal nerve fiber layer in color fundus images.

    Science.gov (United States)

    Odstrcilik, Jan; Kolar, Radim; Tornow, Ralf-Peter; Jan, Jiri; Budai, Attila; Mayer, Markus; Vodakova, Martina; Laemmer, Robert; Lamos, Martin; Kuna, Zdenek; Gazarek, Jiri; Kubena, Tomas; Cernosek, Pavel; Ronzhina, Marina

    2014-09-01

    Images of ocular fundus are routinely utilized in ophthalmology. Since an examination using fundus camera is relatively fast and cheap procedure, it can be used as a proper diagnostic tool for screening of retinal diseases such as the glaucoma. One of the glaucoma symptoms is progressive atrophy of the retinal nerve fiber layer (RNFL) resulting in variations of the RNFL thickness. Here, we introduce a novel approach to capture these variations using computer-aided analysis of the RNFL textural appearance in standard and easily available color fundus images. The proposed method uses the features based on Gaussian Markov random fields and local binary patterns, together with various regression models for prediction of the RNFL thickness. The approach allows description of the changes in RNFL texture, directly reflecting variations in the RNFL thickness. Evaluation of the method is carried out on 16 normal ("healthy") and 8 glaucomatous eyes. We achieved significant correlation (normals: ρ=0.72±0.14; p≪0.05, glaucomatous: ρ=0.58±0.10; p≪0.05) between values of the model predicted output and the RNFL thickness measured by optical coherence tomography, which is currently regarded as a standard glaucoma assessment device. The evaluation thus revealed good applicability of the proposed approach to measure possible RNFL thinning. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Incidence of Apical Crack Initiation during Canal Preparation using Hand Stainless Steel (K-File) and Hand NiTi (Protaper) Files.

    Science.gov (United States)

    Soni, Dileep; Raisingani, Deepak; Mathur, Rachit; Madan, Nidha; Visnoi, Suchita

    2016-01-01

    To evaluate the incidence of apical crack initiation during canal preparation with stainless steel K-files and hand protaper files (in vitro study). Sixty extracted mandibular premo-lar teeth are randomly selected and embedded in an acrylic tube filled with autopolymerizing resin. A baseline image of the apical surface of each specimen was recorded under a digital microscope (80×). The cervical and middle thirds of all samples were flared with #2 and #1 Gates-Glidden (GG) drills, and a second image was recorded. The teeth were randomly divided into four groups of 15 teeth each according to the file type (hand K-file and hand-protaper) and working length (WL) (instrumented at WL and 1 mm less than WL). Final image after dye penetration and photomicrograph of the apical root surface were digitally recorded. Maximum numbers of cracks were observed with hand protaper files compared with hand K-file at the WL and 1 mm short of WL. Chi-square testing revealed a highly significant effect of WL on crack formation at WL and 1 mm short of WL (p = 0.000). Minimum numbers of cracks at WL and 1 mm short of WL were observed with hand K-file and maximum with hand protaper files. Soni D, Raisingani D, Mathur R, Madan N, Visnoi S. Incidence of Apical Crack Initiation during Canal Preparation using Hand Stainless Steel (K-File) and Hand NiTi (Protaper) Files. Int J Clin Pediatr Dent 2016;9(4):303-307.

  5. Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.

    Science.gov (United States)

    Li, Zhixi; He, Yifan; Keel, Stuart; Meng, Wei; Chang, Robert T; He, Mingguang

    2018-03-02

    To assess the performance of a deep learning algorithm for detecting referable glaucomatous optic neuropathy (GON) based on color fundus photographs. A deep learning system for the classification of GON was developed for automated classification of GON on color fundus photographs. We retrospectively included 48 116 fundus photographs for the development and validation of a deep learning algorithm. This study recruited 21 trained ophthalmologists to classify the photographs. Referable GON was defined as vertical cup-to-disc ratio of 0.7 or more and other typical changes of GON. The reference standard was made until 3 graders achieved agreement. A separate validation dataset of 8000 fully gradable fundus photographs was used to assess the performance of this algorithm. The area under receiver operator characteristic curve (AUC) with sensitivity and specificity was applied to evaluate the efficacy of the deep learning algorithm detecting referable GON. In the validation dataset, this deep learning system achieved an AUC of 0.986 with sensitivity of 95.6% and specificity of 92.0%. The most common reasons for false-negative grading (n = 87) were GON with coexisting eye conditions (n = 44 [50.6%]), including pathologic or high myopia (n = 37 [42.6%]), diabetic retinopathy (n = 4 [4.6%]), and age-related macular degeneration (n = 3 [3.4%]). The leading reason for false-positive results (n = 480) was having other eye conditions (n = 458 [95.4%]), mainly including physiologic cupping (n = 267 [55.6%]). Misclassification as false-positive results amidst a normal-appearing fundus occurred in only 22 eyes (4.6%). A deep learning system can detect referable GON with high sensitivity and specificity. Coexistence of high or pathologic myopia is the most common cause resulting in false-negative results. Physiologic cupping and pathologic myopia were the most common reasons for false-positive results. Copyright © 2018 American Academy of Ophthalmology. Published by

  6. Multimodal segmentation of optic disc and cup from stereo fundus and SD-OCT images

    Science.gov (United States)

    Miri, Mohammad Saleh; Lee, Kyungmoo; Niemeijer, Meindert; Abràmoff, Michael D.; Kwon, Young H.; Garvin, Mona K.

    2013-03-01

    Glaucoma is one of the major causes of blindness worldwide. One important structural parameter for the diagnosis and management of glaucoma is the cup-to-disc ratio (CDR), which tends to become larger as glaucoma progresses. While approaches exist for segmenting the optic disc and cup within fundus photographs, and more recently, within spectral-domain optical coherence tomography (SD-OCT) volumes, no approaches have been reported for the simultaneous segmentation of these structures within both modalities combined. In this work, a multimodal pixel-classification approach for the segmentation of the optic disc and cup within fundus photographs and SD-OCT volumes is presented. In particular, after segmentation of other important structures (such as the retinal layers and retinal blood vessels) and fundus-to-SD-OCT image registration, features are extracted from both modalities and a k-nearest-neighbor classification approach is used to classify each pixel as cup, rim, or background. The approach is evaluated on 70 multimodal image pairs from 35 subjects in a leave-10%-out fashion (by subject). A significant improvement in classification accuracy is obtained using the multimodal approach over that obtained from the corresponding unimodal approach (97.8% versus 95.2%; p < 0:05; paired t-test).

  7. Detection of exudates in fundus imagery using a constant false-alarm rate (CFAR) detector

    Science.gov (United States)

    Khanna, Manish; Kapoor, Elina

    2014-05-01

    Diabetic retinopathy is the leading cause of blindness in adults in the United States. The presence of exudates in fundus imagery is the early sign of diabetic retinopathy so detection of these lesions is essential in preventing further ocular damage. In this paper we present a novel technique to automatically detect exudates in fundus imagery that is robust against spatial and temporal variations of background noise. The detection threshold is adjusted dynamically, based on the local noise statics around the pixel under test in order to maintain a pre-determined, constant false alarm rate (CFAR). The CFAR detector is often used to detect bright targets in radar imagery where the background clutter can vary considerably from scene to scene and with angle to the scene. Similarly, the CFAR detector addresses the challenge of detecting exudate lesions in RGB and multispectral fundus imagery where the background clutter often exhibits variations in brightness and texture. These variations present a challenge to common, global thresholding detection algorithms and other methods. Performance of the CFAR algorithm is tested against a publicly available, annotated, diabetic retinopathy database and preliminary testing suggests that performance of the CFAR detector proves to be superior to techniques such as Otsu thresholding.

  8. Intrarater reliability of hand held dynamometry in measuring lower extremity isometric strength using a portable stabilization device.

    Science.gov (United States)

    Jackson, Steven M; Cheng, M Samuel; Smith, A Russell; Kolber, Morey J

    2017-02-01

    Hand held dynamometry (HHD) is a more objective way to quantify muscle force production (MP) compared to traditional manual muscle testing. HHD reliability can be negatively impacted by both the strength of the tester and the subject particularly in the lower extremities due to larger muscle groups. The primary aim of this investigation was to assess intrarater reliability of HHD with use of a portable stabilization device for lower extremity MP in an athletic population. Isometric lower extremity strength was measured for bilateral lower extremities including hip abductors, external rotators, adductors, knee extensors, and ankle plantar flexors was measured in a sample of healthy recreational runners (8 male, 7 females, = 30 limbs) training for a marathon. These measurements were assessed using an intrasession intrarater reliability design. Intraclass correlation coefficients (ICC) were calculated using 3,1 model based on the single rater design. The standard error of measurement (SEM) for each muscle group was also calculated. ICC were excellent ranging from ICC (3,1) = 0.93-0.98 with standard error of measurements ranging from 0.58 to 17.2 N. This study establishes the use of a HHD with a portable stabilization device as demonstrating good reliability within testers for measuring lower extremity muscle performance in an active healthy population. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Hands on, mobiles on The use of a digital narrative as a scaffolding remedy in a classical science centre

    Directory of Open Access Journals (Sweden)

    Anne Kahr-Højland

    2010-12-01

    Full Text Available This article examines an educational design experiment which aimed to support young people’s involvement and reflection in the exhibition at a Danish science centre. The experiment consisted in the examination of the design and implementation of a mobile phone facilitated narrative, which was planned as a so-called scaffolding remedy in the hands-on based exhibition. The digital narrative, called EGO-TRAP, was developed using Design-Based Research as the overall methodological framework. The study of students’ interactions in the exhibition suggests, among other things, that because of its quality as a digital narrative, EGO-TRAP scaffolds pleasurable engagement and counteracts the tendency of "random button pressing" that often occurs in classical science centre exhibitions. In this connection, the mobile phone plays an essential role due to the fact that it, as the favoured media by the young students, offers an experience which they describe as both personal and flexible.

  10. Application of 3-dimensional printing technology to construct an eye model for fundus viewing study.

    Directory of Open Access Journals (Sweden)

    Ping Xie

    Full Text Available To construct a life-sized eye model using the three-dimensional (3D printing technology for fundus viewing study of the viewing system.We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs. Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical design software. With computer aided design (CAD software, we designed the 3D digital model of the main structure of the physical model eye, which was used for three-dimensional (3D printing. Together with the main printed structure, polymethyl methacrylate(PMMA aspherical cornea, variable iris, and IOLs were assembled to a physical eye model. Angle scale bars were glued from posterior to periphery of the retina. Then we fabricated other three physical models with different states of ammetropia. Optical parameters of these physical eye models were measured to verify the 3D printing accuracy.In on-axis calculations, our schematic model eye possessed similar size of spot diagram compared with Navarro's and Bakaraju's model eye, much smaller than Arianpour's model eye. Moreover, the spherical aberration of our schematic eye was much less than other three model eyes. While in off- axis simulation, it possessed a bit higher coma and similar astigmatism, field curvature and distortion. The MTF curves showed that all the model eyes diminished in resolution with increasing field of view, and the diminished tendency of resolution of our physical eye model was similar to the Navarro's eye. The measured parameters of our eye models with different status of ametropia were in line with the theoretical value.The schematic eye model we designed can well simulate the optical performance of the human eye, and the fabricated physical one can be used as a tool in fundus range viewing research.

  11. Application of 3-dimensional printing technology to construct an eye model for fundus viewing study.

    Science.gov (United States)

    Xie, Ping; Hu, Zizhong; Zhang, Xiaojun; Li, Xinhua; Gao, Zhishan; Yuan, Dongqing; Liu, Qinghuai

    2014-01-01

    To construct a life-sized eye model using the three-dimensional (3D) printing technology for fundus viewing study of the viewing system. We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs). Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical design software. With computer aided design (CAD) software, we designed the 3D digital model of the main structure of the physical model eye, which was used for three-dimensional (3D) printing. Together with the main printed structure, polymethyl methacrylate(PMMA) aspherical cornea, variable iris, and IOLs were assembled to a physical eye model. Angle scale bars were glued from posterior to periphery of the retina. Then we fabricated other three physical models with different states of ammetropia. Optical parameters of these physical eye models were measured to verify the 3D printing accuracy. In on-axis calculations, our schematic model eye possessed similar size of spot diagram compared with Navarro's and Bakaraju's model eye, much smaller than Arianpour's model eye. Moreover, the spherical aberration of our schematic eye was much less than other three model eyes. While in off- axis simulation, it possessed a bit higher coma and similar astigmatism, field curvature and distortion. The MTF curves showed that all the model eyes diminished in resolution with increasing field of view, and the diminished tendency of resolution of our physical eye model was similar to the Navarro's eye. The measured parameters of our eye models with different status of ametropia were in line with the theoretical value. The schematic eye model we designed can well simulate the optical performance of the human eye, and the fabricated physical one can be used as a tool in fundus range viewing research.

  12. Performance of hand-held whole-breast ultrasound based on BI-RADS in women with mammographically negative dense breast

    International Nuclear Information System (INIS)

    Youk, Ji Hyun; Kim, Eun-Kyung; Kim, Min Jung; Kwak, Jin Young; Son, Eun Ju

    2011-01-01

    To assess the performance of breast ultrasound based on BI-RADS final assessment categories in women with mammographically negative dense breast. Of 3,820 cases with mammographically negative dense breast and subsequent hand-held bilateral whole-breast ultrasound, a total of 1,507 cases in 1,046 women who had biopsy or at least 2-year follow-up ultrasound constituted the basis of this retrospective study. Cancer rate of each sonographic BI-RADS category was determined and medical audit was performed separately in screening-general, screening-treated, and diagnostic group. A total of 43 cases (2.9%) were confirmed as malignancy. Cancer rate among BI-RADS categories was significantly different (p < 0.0001). Among three groups, the cancer rate was significantly different (p < 0.0001) and the highest in diagnostic group (15.8%, 22 of 139). Abnormal interpretation rate, PPV of biopsy performed, cancer detection rate, and rate of early stage cancer, and the size of invasive cancer were significantly different among three groups and the highest in diagnostic group. Regarding cancer characteristics, the proportion of advanced cancer was the highest in diagnostic group. Breast ultrasound based on BI-RADS as an adjunctive to negative mammography can be useful for predicting malignancy in women with dense breast. (orig.)

  13. Detailed Morphological Changes of Foveoschisis in Patient with X-Linked Retinoschisis Detected by SD-OCT and Adaptive Optics Fundus Camera

    Directory of Open Access Journals (Sweden)

    Keiichiro Akeo

    2015-01-01

    Full Text Available Purpose. To report the morphological and functional changes associated with a regression of foveoschisis in a patient with X-linked retinoschisis (XLRS. Methods. A 42-year-old man with XLRS underwent genetic analysis and detailed ophthalmic examinations. Functional assessments included best-corrected visual acuity (BCVA, full-field electroretinograms (ERGs, and multifocal ERGs (mfERGs. Morphological assessments included fundus photography, spectral-domain optical coherence tomography (SD-OCT, and adaptive optics (AO fundus imaging. After the baseline clinical data were obtained, topical dorzolamide was applied to the patient. The patient was followed for 24 months. Results. A reported RS1 gene mutation was found (P203L in the patient. At the baseline, his decimal BCVA was 0.15 in the right and 0.3 in the left eye. Fundus photographs showed bilateral spoke wheel-appearing maculopathy. SD-OCT confirmed the foveoschisis in the left eye. The AO images of the left eye showed spoke wheel retinal folds, and the folds were thinner than those in fundus photographs. During the follow-up period, the foveal thickness in the SD-OCT images and the number of retinal folds in the AO images were reduced. Conclusions. We have presented the detailed morphological changes of foveoschisis in a patient with XLRS detected by SD-OCT and AO fundus camera. However, the findings do not indicate whether the changes were influenced by topical dorzolamide or the natural history.

  14. An Enhanced Data Integrity Model In Mobile Cloud Environment Using Digital Signature Algorithm And Robust Reversible Watermarking

    Directory of Open Access Journals (Sweden)

    Boukari Souley

    2017-10-01

    Full Text Available the increase use of hand held devices such as smart phones to access multimedia content in the cloud is increasing with rise and growth in information technology. Mobile cloud computing is increasingly used today because it allows users to have access to variety of resources in the cloud such as image video audio and software applications with minimal usage of their inbuilt resources such as storage memory by using the one available in the cloud. The major challenge faced with mobile cloud computing is security. Watermarking and digital signature are some techniques used to provide security and authentication on user data in the cloud. Watermarking is a technique used to embed digital data within a multimedia content such as image video or audio in order to prevent authorized access to those content by intruders whereas digital signature is used to identify and verify user data when accessed. In this work we implemented digital signature and robust reversible image watermarking in order enhance mobile cloud computing security and integrity of data by providing double authentication techniques. The results obtained show the effectiveness of combining the two techniques robust reversible watermarking and digital signature by providing strong authentication to ensures data integrity and extract the original content watermarked without changes.

  15. Evaluation of an online peer fundus photograph matching program in teaching direct ophthalmoscopy to medical students.

    Science.gov (United States)

    Kwok, Jason; Liao, Walter; Baxter, Stephanie

    2017-10-01

    Direct ophthalmoscopy is an important clinical skill that is often poorly performed by medical professionals and students. This is attributable to a declining emphasis on ophthalmology in medical school. We present and evaluate a self-directed approach of teaching ophthalmoscopy to medical students that is suitable for the current medical curriculum. Prospective medical education trial. Ninety-five second-year medical students at Queen's University: 32 in the experimental group and 63 in the control group. The experimental group consisted of medical students who practised ophthalmoscopy with one another using an online peer fundus photograph matching exercise created by the Department of Ophthalmology at Queen's University. To use the program, students first examined a peer with an ophthalmoscope and then selected an online photograph of a fundus corresponding to that of the examinee. The program notifies students if a correct selection is made. To encourage use of the program, students participated in a 2-week ophthalmoscopy competition during their ophthalmology rotation. The control group consisted of students who did not participate in the learning exercise. On assessment at the end of the ophthalmology rotation, the experimental group (n = 32) was more accurate in matching fundus photographs compared with the control group (n = 63) (p = 0.02). Participants were faster at performing ophthalmoscopy at the end of the learning exercise (p peer fundus photographs in a self-directed manner appeared to increase the skill and confidence of medical students in ophthalmoscopy. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  16. Teaching digital pathology: The international school of digital pathology and proposed syllabus

    Directory of Open Access Journals (Sweden)

    Vincenzo Della Mea

    2017-01-01

    Full Text Available Digital pathology is an interdisciplinary field where competency in pathology, laboratory techniques, informatics, computer science, information systems, engineering, and even biology converge. This implies that teaching students about digital pathology requires coverage, expertise, and hands-on experience in all these disciplines. With this in mind, a syllabus was developed for a digital pathology summer school aimed at professionals in the aforementioned fields, as well as trainees and doctoral students. The aim of this communication is to share the context, rationale, and syllabus for this school of digital pathology.

  17. Digitized hand-wrist radiographs: comparison of subjective and software-derived image quality at various compression ratios.

    Science.gov (United States)

    McCord, Layne K; Scarfe, William C; Naylor, Rachel H; Scheetz, James P; Silveira, Anibal; Gillespie, Kevin R

    2007-05-01

    The objectives of this study were to compare the effect of JPEG 2000 compression of hand-wrist radiographs on observer image quality qualitative assessment and to compare with a software-derived quantitative image quality index. Fifteen hand-wrist radiographs were digitized and saved as TIFF and JPEG 2000 images at 4 levels of compression (20:1, 40:1, 60:1, and 80:1). The images, including rereads, were viewed by 13 orthodontic residents who determined the image quality rating on a scale of 1 to 5. A quantitative analysis was also performed by using a readily available software based on the human visual system (Image Quality Measure Computer Program, version 6.2, Mitre, Bedford, Mass). ANOVA was used to determine the optimal compression level (P quality. When we used quantitative indexes, the JPEG 2000 images had lower quality at all compression ratios compared with the original TIFF images. There was excellent correlation (R2 >0.92) between qualitative and quantitative indexes. Image Quality Measure indexes are more sensitive than subjective image quality assessments in quantifying image degradation with compression. There is potential for this software-based quantitative method in determining the optimal compression ratio for any image without the use of subjective raters.

  18. Modification of a Kowa RC-2 fundus camera for self-photography without the use of mydriatics.

    Science.gov (United States)

    Philpott, D E; Bailey, P F; Harrison, G; Turnbill, C

    1979-01-01

    Research on retinal circulation during space flight required the development of a simple technique to provide self monitoring of blood vessel changes in the fundus without the use of mydriatics. A Kowa RC-2 fundus camera was modified for self-photography by the use of a bite plate for positioning and cross hairs for focusing the subject's retina relative to the film plane. Dilation of the pupils without the use of mydriatics was accomplished by dark adaption of the subject. Pictures were obtained without pupil constriction by the use of a high speed strobe light. This method also has applications for clinical medicine.

  19. Interactive segmentation for geographic atrophy in retinal fundus images

    OpenAIRE

    Lee, Noah; Smith, R. Theodore; Laine, Andrew F.

    2008-01-01

    Fundus auto-fluorescence (FAF) imaging is a non-invasive technique for in vivo ophthalmoscopic inspection of age-related macular degeneration (AMD), the most common cause of blindness in developed countries. Geographic atrophy (GA) is an advanced form of AMD and accounts for 12–21% of severe visual loss in this disorder [3]. Automatic quantification of GA is important for determining disease progression and facilitating clinical diagnosis of AMD. The problem of automatic segmentation of patho...

  20. Successful replantation in ten-digit amputation.

    Science.gov (United States)

    Kantarci, Umit; Cepel, Selim; Buldu, Halil

    2010-01-01

    Amputations involving ten digits are very rare because of different lengths of the digits. A 34-year-old man working in a printing house presented one hour after guillotine amputation involving all ten digits. Surgery was initiated 80 minutes after admission and took seven hours. Under axillary anesthesia, the operation was performed by two teams each consisting of two microsurgeons and two assistants. Replantation was completed without the use of any skin graft or flap. Fingertip examination showed poor arterial circulation in the second, third, and fourth digits of the left hand after 24 hours of replantation and surgical exploration was performed, during which anastomosis of the ulnar digital artery of the second digit was re-established and a Y-shaped vein graft was placed at the level of the third web to restore revascularization of the third and fourth digits. However, these interventions did not prevent the development of necrosis in the distal segment of the fourth digit which resulted in dry gangrene that required amputation. After 38 months of replantation, radiographic examination showed complete union in all fingers without malunion or damage to the joint surface and about 8 degrees of medial angulation in the proximal phalanx of the fourth digit of the right hand. The patient did not have difficulty in performing daily activities and had a considerably good pinching. Losses of active range of motion of the metacarpophalangeal and interphalangeal joints were within the rage of 10 to 30 degrees in both hands. In the assessment of sensation, static and dynamic two-point discrimination test results were 6.1 mm and 4.0 mm, respectively.

  1. Using an Analysis of Behavior Change to Inform Effective Digital Intervention Design: How Did the PRIMIT Website Change Hand Hygiene Behavior Across 8993 Users?

    Science.gov (United States)

    Ainsworth, B; Steele, M; Stuart, B; Joseph, J; Miller, S; Morrison, L; Little, P; Yardley, L

    2017-06-01

    In designing digital interventions for healthcare, it is important to understand not just whether interventions work but also how and for whom-including whether individual intervention components have different effects, whether a certain usage threshold is required to change behavior in each intervention and whether usage differs across population subgroups. We investigated these questions using data from a large trial of the digital PRimary care trial of a website based Infection control intervention to Modify Influenza-like illness and respiratory tract infection Transmission) (PRIMIT) intervention, which aimed to reduce respiratory tract infections (RTIs) by increasing hand hygiene behavior. Baseline and follow-up questionnaires measured behaviors, intentions and attitudes in hand hygiene. In conjunction with objective measures of usage of the four PRIMIT sessions, we analysed these observational data to examine mechanisms of behavior change in 8993 intervention users. We found that the PRIMIT intervention changed behavior, intentions and attitudes, and this change was associated with reduced RTIs. The largest hand hygiene change occurred after the first session, with incrementally smaller changes after each subsequent session, suggesting that engagement with the core behavior change techniques included in the first session was necessary and sufficient for behavior change. The intervention was equally effective for men and women, older and younger people and was particularly effective for those with lower levels of education. Our well-powered analysis has implications for intervention development. We were able to determine a 'minimum threshold' of intervention engagement that is required for hand hygiene change, and we discuss the potential implications this (and other analyses of this type) may have for further intervention development. We also discuss the application of similar analyses to other interventions.

  2. The Learning Preferences of Digital Learners in K-12 Schools in China

    Science.gov (United States)

    Yang, Junfeng; Huang, Ronghuai; Kinshuk

    2016-01-01

    Students grown up with digital technology and Internet are called digital natives or net generation. All others, who grew up without so much immersion with digital technologies are called digital immigrants. Researchers held different ideas on whether a new generation of learners existed. One of the foci of the debate is on the appropriateness of…

  3. Detection of retinal nerve fiber layer defects in retinal fundus images using Gabor filtering

    Science.gov (United States)

    Hayashi, Yoshinori; Nakagawa, Toshiaki; Hatanaka, Yuji; Aoyama, Akira; Kakogawa, Masakatsu; Hara, Takeshi; Fujita, Hiroshi; Yamamoto, Tetsuya

    2007-03-01

    Retinal nerve fiber layer defect (NFLD) is one of the most important findings for the diagnosis of glaucoma reported by ophthalmologists. However, such changes could be overlooked, especially in mass screenings, because ophthalmologists have limited time to search for a number of different changes for the diagnosis of various diseases such as diabetes, hypertension and glaucoma. Therefore, the use of a computer-aided detection (CAD) system can improve the results of diagnosis. In this work, a technique for the detection of NFLDs in retinal fundus images is proposed. In the preprocessing step, blood vessels are "erased" from the original retinal fundus image by using morphological filtering. The preprocessed image is then transformed into a rectangular array. NFLD regions are observed as vertical dark bands in the transformed image. Gabor filtering is then applied to enhance the vertical dark bands. False positives (FPs) are reduced by a rule-based method which uses the information of the location and the width of each candidate region. The detected regions are back-transformed into the original configuration. In this preliminary study, 71% of NFLD regions are detected with average number of FPs of 3.2 per image. In conclusion, we have developed a technique for the detection of NFLDs in retinal fundus images. Promising results have been obtained in this initial study.

  4. A Deep Learning Algorithm for Prediction of Age-Related Eye Disease Study Severity Scale for Age-Related Macular Degeneration from Color Fundus Photography.

    Science.gov (United States)

    Grassmann, Felix; Mengelkamp, Judith; Brandl, Caroline; Harsch, Sebastian; Zimmermann, Martina E; Linkohr, Birgit; Peters, Annette; Heid, Iris M; Palm, Christoph; Weber, Bernhard H F

    2018-04-10

    Age-related macular degeneration (AMD) is a common threat to vision. While classification of disease stages is critical to understanding disease risk and progression, several systems based on color fundus photographs are known. Most of these require in-depth and time-consuming analysis of fundus images. Herein, we present an automated computer-based classification algorithm. Algorithm development for AMD classification based on a large collection of color fundus images. Validation is performed on a cross-sectional, population-based study. We included 120 656 manually graded color fundus images from 3654 Age-Related Eye Disease Study (AREDS) participants. AREDS participants were >55 years of age, and non-AMD sight-threatening diseases were excluded at recruitment. In addition, performance of our algorithm was evaluated in 5555 fundus images from the population-based Kooperative Gesundheitsforschung in der Region Augsburg (KORA; Cooperative Health Research in the Region of Augsburg) study. We defined 13 classes (9 AREDS steps, 3 late AMD stages, and 1 for ungradable images) and trained several convolution deep learning architectures. An ensemble of network architectures improved prediction accuracy. An independent dataset was used to evaluate the performance of our algorithm in a population-based study. κ Statistics and accuracy to evaluate the concordance between predicted and expert human grader classification. A network ensemble of 6 different neural net architectures predicted the 13 classes in the AREDS test set with a quadratic weighted κ of 92% (95% confidence interval, 89%-92%) and an overall accuracy of 63.3%. In the independent KORA dataset, images wrongly classified as AMD were mainly the result of a macular reflex observed in young individuals. By restricting the KORA analysis to individuals >55 years of age and prior exclusion of other retinopathies, the weighted and unweighted κ increased to 50% and 63%, respectively. Importantly, the algorithm

  5. A hand-held imaging probe for radio-guided surgery: physical performance and preliminary clinical experience

    International Nuclear Information System (INIS)

    Pitre, S.; Menard, L.; Charon, Y.; Solal, M.; Garbay, J.R.

    2003-01-01

    Improvements in the specificity of radiopharmaceutical compounds have been paralleled by an upsurge of interest in developing small detectors to assist surgeons in localizing tumour tissue during surgery. This study reports the main technical features and physical characteristics of a new hand-held gamma camera dedicated to accurate and real-time intra-operative imaging. First clinical experience is also reported. The POCI (Per-operative Compact Imager) camera consists of a head module composed of a high-resolution interchangeable lead collimator and a CsI(Na) crystal plate optically coupled to an intensified position-sensitive diode. The current prototype has a 40-mm diameter field of view, an outer diameter of 9.5 cm, a length of 9 cm and a weight of 1.2 kg. Overall detector imaging characteristics were evaluated by technetium-99m phantom measurements. Three patients with breast cancer previously scheduled to undergo sentinel lymph node detection were selected for the preliminary clinical experience. Preoperative images of the lymphatic basin obtained using the POCI camera were compared with conventional transcutaneous explorations using a non-imaging gamma probe. The full-width at half-maximum (FWHM) spatial resolution was investigated in both air and scattering medium; when the phantom was placed in contact with the collimator, the POCI camera exhibited a 3.2 mm FWHM. The corresponding sensitivity was 290 cps/MBq. The preliminary clinical results showed that POCI was able to predict the number and location of all SLNs. In one case, two deep radioactive nodes missed by the gamma probe were detected on the intra-operative images. This very initial experience demonstrates that the physical performance of the POCI camera is adequate for radio-guided surgery. These results are sufficiently encouraging to prompt further evaluation studies designed to determine the specific and optimal clinical role of intra-operative imaging devices

  6. The use of hand-held 35 mm color infrared imagery for estimates of suspended solids - A progress report. [in water pollution monitoring

    Science.gov (United States)

    Miller, W. F.; Whisler, F. D.; Robinette, H. R.; Finnie, D.; Cannon, T.

    1975-01-01

    A cost-effective aerial surveillance technique is proposed for detection and identification of suspended solids which would be operational for both governmental monitoring organizations and private individuals operating catfish farms. Sixteen catfish ponds were flown daily for seven days using two hand-held 35 mm cameras with both Kodachrome X and Ektachrome infrared film. Hue, value, and chroma designations were recorded for each pond on each date by three interpreters, and the accepted color was that recorded by at least two of the interpreters, or if there was a three hue range, the median was accepted. Relations between suspended solids and color designations were analyzed graphically, and chroma was discarded due to an apparent lack of correlation. The data obtained were then analyzed by multiple regression. Significant correlations were revealed between hue and value and total and inorganic suspended solids. If perfected, this technique could be developed to sufficent accuracy for large-scale reconnaissance surveys to monitor the quality of rivers and streams.

  7. Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices.

    Science.gov (United States)

    Mair, B; Drillich, M; Klein-Jöbstl, D; Kanz, P; Borchardt, S; Meyer, L; Schwendenwein, I; Iwersen, M

    2016-02-24

    Dairy cows have a massive demand for glucose at the onset of lactation. A poor adaption to this period leads to an excessive negative energy balance with an increased risk for ketosis and impaired animal health and production. Besides the measurement of ketones, analysing the glucose concentration in blood is reported as helpful instrument for diagnosis and differentiation of ketosis. Monitoring metabolic parameters requires multiple blood sampling. In other species, new blood sampling techniques have been introduced in which small amounts of blood are rapidly analysed using electronic hand-held devices. The objective of this study was to evaluate the suitability of capillary blood for blood glucose measurement in dairy cows using the hand-held devices FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini) and the WellionVet GLUCO CALEA, (WGC, MED TRUST). In total, 240 capillary blood samples were obtained from dry and fresh lactating Holstein-Friesian cows. Blood was collected from the skin of the exterior vulva by using a lancet. For method comparison, additional blood samples were taken from a coccygeal vessel and analyzed in a laboratory. Glucose concentrations measured by a standard laboratory method were defined as the criterion standard. The Pearson correlation coefficients between the glucose concentrations analyzed in capillary blood with the devices and the reference were 73% for the FSP, 81% for the GLX and 41% for the WGC. Bland-Altman plots showed biases of -18.8 mg/dL for the FSP, -11.2 mg/dL for the GLX and +20.82 mg/dL for the WGC. The optimized threshold determined by a Receiver Operating Characteristics analysis to detect hyperglycemia using the FSP was 43 mg/dL with a sensitivity (Se) and specificity (Sp) of 76 and 80%. Using the GLX and WGC optimized thresholds were 49 mg/dL (Se = 92%, Sp = 85%) and 95 mg/dL (Se = 39%, Sp = 92%). The results of this study demonstrate good performance characteristics for the GLX

  8. Digital collections and exhibits

    CERN Document Server

    Denzer, Juan

    2015-01-01

    Today's libraries are taking advantage of cutting-edge technologies such as flat panel displays using touch, sound, and hands-free motions to design amazing exhibits using everything from simple computer hardware to advanced technologies such as the Microsoft Kinect. Libraries of all types are striving to add new interactive experiences for their patrons through exciting digital exhibits, both online and off. Digital Collections and Exhibits takes away the mystery of designing stunning digital exhibits to spotlight library trea

  9. The tropical diabetic hand syndrome: a surgical perspective.

    Science.gov (United States)

    Nthumba, Peter; Cavadas, Pedro C; Landin, Luis

    2013-01-01

    Tropical diabetic hand syndrome (TDHS) is an aggressive type of hand sepsis that results in significant morbidity and mortality among patients with diabetes in the tropics. This study set out to establish a protocol for the holistic management of TDHS to improve digit/hand salvage and function at AIC Kijabe Hospital. This prospective study examined the following demographics of patients presenting to the authors institution between October 2009 and September 2010 with TDHS: their sex, age, comorbidities, length of in-hospital stay, surgical and medical treatment, total cost of treatment, and immediate postdischarge outcomes. A total of 10 patients (3 men and 7 women) were presented with TDHS during the study period. Surgical procedures included a thorough debridement of the hand at initial presentation, followed by procedures aimed at preserving length and hand function, with digit or hand amputation when there was no possibility of salvage. Three hands were salvaged, without the need for an amputation; 2 of these, however, developed severe stiffness with resultant poor function. Fifty percent of the patients developed considerable disability; 3 of these patients had disabilities of the arm, shoulder, and hand, (DASH) scores of >90 at 6 months after treatment. TDHS appears to be more aggressive in some patients than in others; a multidisciplinary approach, with early involvement of the surgical team, and a radical surgical debridement are essential to improved outcomes. Although the goal of medical treatment (ie, glycemic control) is simple and easily achieved, surgical goals (salvage of limb or life, preservation of hand function) are more complex, costly, and difficult to achieve. Educating health care workers, diabetic patients, and their relatives on hand care is an important preventive measure. Diligence in taking antidiabetic medicine, early presentation, and appropriate care of TDHS are required for meaningful improvement in outcomes of patients with

  10. Systems and methods for automatically identifying and linking names in digital resources

    Science.gov (United States)

    Parker, Charles T.; Lyons, Catherine M.; Roston, Gerald P.; Garrity, George M.

    2017-06-06

    The present invention provides systems and methods for automatically identifying name-like-strings in digital resources, matching these name-like-string against a set of names held in an expertly curated database, and for those name-like-strings found in said database, enhancing the content by associating additional matter with the name, wherein said matter includes information about the names that is held within said database and pointers to other digital resources which include the same name and it synonyms.

  11. Evaluation of an automated breast 3D-ultrasound system by comparing it with hand-held ultrasound (HHUS) and mammography.

    Science.gov (United States)

    Golatta, Michael; Baggs, Christina; Schweitzer-Martin, Mirjam; Domschke, Christoph; Schott, Sarah; Harcos, Aba; Scharf, Alexander; Junkermann, Hans; Rauch, Geraldine; Rom, Joachim; Sohn, Christof; Heil, Joerg

    2015-04-01

    Automated three-dimensional (3D) breast ultrasound (US) systems are meant to overcome the shortcomings of hand-held ultrasound (HHUS). The aim of this study is to analyze and compare clinical performance of an automated 3D-US system by comparing it with HHUS, mammography and the clinical gold standard (defined as the combination of HHUS, mammography and-if indicated-histology). Nine hundred and eighty three patients (=1,966 breasts) were enrolled in this monocentric, explorative and prospective cohort study. All examinations were analyzed blinded to the patients´ history and to the results of the routine imaging. The agreement of automated 3D-US with HHUS, mammography and the gold standard was assessed with kappa statistics. Sensitivity, specificity and positive and negative predictive value were calculated to assess the test performance. Blinded to the results of the gold standard the agreement between automated 3D-US and HHUS or mammography was fair, given by a Kappa coefficient of 0.31 (95% CI [0.26;0.36], p automated 3D-US the sensitivity improved to 84% (NPV = 99%, specificity = 85%). The results of this study let us suggest, that automated 3D-US might be a helpful new tool in breast imaging, especially in screening.

  12. A simple hand-held magnet array for efficient and reproducible SABRE hyperpolarisation using manual sample shaking.

    Science.gov (United States)

    Richardson, Peter M; Jackson, Scott; Parrott, Andrew J; Nordon, Alison; Duckett, Simon B; Halse, Meghan E

    2018-07-01

    Signal amplification by reversible exchange (SABRE) is a hyperpolarisation technique that catalytically transfers nuclear polarisation from parahydrogen, the singlet nuclear isomer of H 2 , to a substrate in solution. The SABRE exchange reaction is carried out in a polarisation transfer field (PTF) of tens of gauss before transfer to a stronger magnetic field for nuclear magnetic resonance (NMR) detection. In the simplest implementation, polarisation transfer is achieved by shaking the sample in the stray field of a superconducting NMR magnet. Although convenient, this method suffers from limited reproducibility and cannot be used with NMR spectrometers that do not have appreciable stray fields, such as benchtop instruments. Here, we use a simple hand-held permanent magnet array to provide the necessary PTF during sample shaking. We find that the use of this array provides a 25% increase in SABRE enhancement over the stray field approach, while also providing improved reproducibility. Arrays with a range of PTFs were tested, and the PTF-dependent SABRE enhancements were found to be in excellent agreement with comparable experiments carried out using an automated flow system where an electromagnet is used to generate the PTF. We anticipate that this approach will improve the efficiency and reproducibility of SABRE experiments carried out using manual shaking and will be particularly useful for benchtop NMR, where a suitable stray field is not readily accessible. The ability to construct arrays with a range of PTFs will also enable the rapid optimisation of SABRE enhancement as function of PTF for new substrate and catalyst systems. © 2017 The Authors Magnetic Resonance in Chemistry Published by John Wiley & Sons Ltd.

  13. Two-photon excited fluorescence microscopy application for ex vivo investigation of ocular fundus samples

    Science.gov (United States)

    Peters, Sven; Hammer, Martin; Schweitzer, Dietrich

    2011-07-01

    Two-photon excited fluorescence (TPEF) imaging of ocular tissue has recently become a promising tool in ophthalmology for diagnostic and research purposes. The feasibility and the advantages of TPEF imaging, namely deeper tissue penetration and improved high-resolution imaging of microstructures, have been demonstrated lately using human ocular samples. The autofluorescence properties of endogenous fluorophores in ocular fundus tissue are well known from spectrophotometric analysis. But fluorophores, especially when it comes to fluorescence lifetime, typically display a dependence of their fluorescence properties on local environmental parameters. Hence, a more detailed investigation of ocular fundus autofluorescence ideally in vivo is of utmost interest. The aim of this study is to determine space-resolved the stationary and time-resolved fluorescence properties of endogenous fluorophores in ex vivo porcine ocular fundus samples by means of two-photon excited fluorescence spectrum and lifetime imaging microscopy (FSIM/FLIM). By our first results, we characterized the autofluorescence of individual anatomical structures of porcine retina samples excited at 760 nm. The fluorescence properties of almost all investigated retinal layers are relatively homogenous. But as previously unknown, ganglion cell bodies show a significantly shorter fluorescence lifetime compared to the adjacent mueller cells. Since all retinal layers exhibit bi-exponential autofluorescence decays, we were able to achieve a more precise characterization of fluorescence properties of endogenous fluorophores compared to a present in vivo FLIM approach by confocal scanning laser ophthalmoscope (cSLO).

  14. Detection of retinal capillary nonperfusion in fundus fluorescein angiogram of diabetic retinopathy.

    Science.gov (United States)

    Rasta, Seyed Hossein; Nikfarjam, Shima; Javadzadeh, Alireza

    2015-01-01

    Retinal capillary nonperfusion (CNP) is one of the retinal vascular diseases in diabetic retinopathy (DR) patients. As there is no comprehensive detection technique to recognize CNP areas, we proposed a different method for computing detection of ischemic retina, non-perfused (NP) regions, in fundus fluorescein angiogram (FFA) images. Whilst major vessels appear as ridges, non-perfused areas are usually observed as ponds that are surrounded by healthy capillaries in FFA images. A new technique using homomorphic filtering to correct light illumination and detect the ponds surrounded in healthy capillaries on FFA images was designed and applied on DR fundus images. These images were acquired from the diabetic patients who had referred to the Nikookari hospital and were diagnosed for diabetic retinopathy during one year. Our strategy was screening the whole image with a fixed window size, which is small enough to enclose areas with identified topographic characteristics. To discard false nominees, we also performed a thresholding operation on the screen and marked images. To validate its performance we applied our detection algorithm on 41 FFA diabetic retinopathy fundus images in which the CNP areas were manually delineated by three clinical experts. Lesions were found as smooth regions with very high uniformity, low entropy, and small intensity variations in FFA images. The results of automated detection method were compared with manually marked CNP areas so achieved sensitivity of 81%, specificity of 78%, and accuracy of 91%.The result was present as a Receiver operating character (ROC) curve, which has an area under the curve (AUC) of 0.796 with 95% confidence intervals. This technique introduced a new automated detection algorithm to recognize non-perfusion lesions on FFA. This has potential to assist detecting and managing of ischemic retina and may be incorporated into automated grading diabetic retinopathy structures.

  15. A comparison of cup-to-disc ratio estimates by fundus biomicroscopy and stereoscopic optic disc photography in the Tema Eye Survey.

    Science.gov (United States)

    Mwanza, J C; Grover, D S; Budenz, D L; Herndon, L W; Nolan, W; Whiteside-de Vos, J; Hay-Smith, G; Bandi, J R; Bhansali, K A; Forbes, L A; Feuer, W J; Barton, K

    2017-08-01

    PurposeTo determine if there are systematic differences in cup-to-disc ratio (CDR) grading using fundus biomicroscopy compared to stereoscopic disc photograph reading.MethodsThe vertical cup-to-disc ratio (VCDR) and horizontal cup-to-disc ratio (HCDR) of 2200 eyes (testing set) were graded by glaucoma subspecialists through fundus biomicroscopy and by a reading center using stereoscopic disc photos. For validation, the glaucoma experts also estimated VCDR and HCDR using stereoscopic disc photos in a subset of 505 eyes that they had assessed biomicroscopically. Agreement between grading methods was assessed with Bland-Altman plots.ResultsIn both sets, photo reading tended to yield small CDRs marginally larger, but read large CDRs marginally smaller than fundus biomicroscopy. The mean differences in VCDR and HCDR were 0.006±0.18 and 0.05±0.18 (testing set), and -0.053±0.23 and -0.028±0.21 (validation set), respectively. The limits of agreement were ~0.4, which is twice as large as the cutoff of clinically significant CDR difference between methods. CDR estimates differed by 0.2 or more in 33.8-48.7% between methods.ConclusionsThe differences in CDR estimates between fundus biomicroscopy and stereoscopic optic disc photo reading showed a wide variation, and reached clinically significance threshold in a large proportion of patients, suggesting a poor agreement. Thus, glaucoma should be monitored by comparing baseline and subsequent CDR estimates using the same method rather than comparing photographs to fundus biomicroscopy.

  16. Fundus autofluorescence in central serous chorioretinopathy:association with spectral-domain optical coherence tomography and fluorescein angiography

    Directory of Open Access Journals (Sweden)

    Peng Zhang

    2015-10-01

    Full Text Available AIM: To evaluate the correlation among changes in fundus autofluorescence (AF measured using infrared fundus AF (IR-AF and short-wave length fundus AF (SW-AF with changes in spectral-domain optical coherence tomography (SD-OCT and fluorescein angiography (FA in central serous chorioretinopathy (CSC.METHODS:Two hundred and twenty consecutive patients with CSC were included. In addition to AF, patients were assessed by means of SD-OCT and FA. Abnormalities in images of IR-AF, SW-AF, FA were analyzed and correlated with the corresponding outer retinal alterations in SD-OCT findings.RESULTS:Eyes with abnormalities on either IR-AF or SW-AF were found in 256 eyes (58.18%, among them 256 eyes (100% showed abnormal IR-AF, but SW-AF abnormalities were present only in 213 eyes (83.20%. The hypo-IR-AF corresponded to accumulation of sub-retinal liquid, collapse of retinal pigment epithelium (RPE or detachment of RPE with or without RPE leakage point in the corresponding area. The hyper-IR-AF corresponded to the area with loss of the ellipsoid portion of the inner segments and sub-sensory retinal deposits or focal melanogenesis under sensory retina. The hypo-SW-AF corresponded to accumulation of sub-retinal liquid or atrophy of RPE. The hyper-SW-AF associated with sub-sensory retinal deposits, detachment of RPE and focal melanogenesis.CONCLUSION:IR-AF was more sensitive than SW-AF and FA for identifying pathological abnormalities in CSC. The characteristics of IR-AF in CSC were attributable to the modification of melanin in the RPE. IR-AF should be used as a common diagnostic tool for identifying pathological lesion in CSC.KEYWORDS:central serous chorioretinopathy; fluorescein angiography; fundus autofluorescence; optical coherence tomography

  17. Value of wireless personal digital assistants for practice: perceptions of advanced practice nurses.

    Science.gov (United States)

    Garrett, Bernard; Klein, Gerri

    2008-08-01

    The aims were to explore advanced practice nurses' perceptions on wireless Personal Digital Assistant technologies, to establish the type and range of tools that would be useful to support their practice and to identify any requirements and limitations that may impact the implementation of wireless Personal Digital Assistants in practice. The wireless Personal Digital Assistant is becoming established as a hand-held computing tool for healthcare professionals. The reflections of advanced practice nurses' about the value of wireless Personal Digital Assistants and its potential to contribute to improved patient care has not been investigated. A qualitative interpretivist design was used to explore advanced practice nurses' perceptions on the value of wireless Personal Digital Assistant technologies to support their practice. The data were collected using survey questionnaires and individual and focus group interviews with nurse practitioners, clinical nurse specialists and information technology managers based in British Columbia, Canada. An open-coding content analysis was performed using qualitative data analysis software. Wireless Personal Digital Assistant's use supports the principles of pervasivity and is a technology rapidly being adopted by advanced practice nurses. Some nurses indicated a reluctance to integrate wireless Personal Digital Assistant technologies into their practices because of the cost and the short technological life cycle of these devices. Many of the barriers which precluded the use of wireless networks within facilities are being removed. Nurses demonstrated a complex understanding of wireless Personal Digital Assistant technologies and gave good rationales for its integration in their practice. Nurses identified improved client care as the major benefit of this technology in practice and the type and range of tools they identified included clinical reference tools such as drug and diagnostic/laboratory reference applications and wireless

  18. EVALUATION OF PATCHY ATROPHY SECONDARY TO HIGH MYOPIA BY SEMIAUTOMATED SOFTWARE FOR FUNDUS AUTOFLUORESCENCE ANALYSIS.

    Science.gov (United States)

    Miere, Alexandra; Capuano, Vittorio; Serra, Rita; Jung, Camille; Souied, Eric; Querques, Giuseppe

    2017-05-31

    To evaluate the progression of patchy atrophy in high myopia using semiautomated software for fundus autofluorescence (FAF) analysis. The medical records and multimodal imaging of 21 consecutive highly myopic patients with macular chorioretinal patchy atrophy (PA) were retrospectively analyzed. All patients underwent repeated fundus autofluorescence and spectral domain optical coherence tomography over at least 12 months. Color fundus photography was also performed in a subset of patients. Total atrophy area was measured on FAF images using Region Finder semiautomated software embedded in Spectralis (Heidelberg Engineering, Heidelberg, Germany) at baseline and during follow-up visits. Region Finder was compared with manually measured PA on FAF images. Twenty-two eyes of 21 patients (14 women, 7 men; mean age 62.8 + 13.0 years, range 32-84 years) were included. Mean PA area using Region Finder was 2.77 ± 2.91 SD mm at baseline, 3.12 ± 2.68 mm at Month 6, 3.43 ± 2.68 mm at Month 12, and 3.73 ± 2.74 mm at Month 18 (overall P autofluorescence analysis by Region Finder semiautomated software provides accurate measurements of lesion area and allows us to quantify the progression of PA in high myopia. In our series, PA enlarged significantly over at least 12 months, and its progression seemed to be related to the lesion size at baseline.

  19. Analysis of Fundus Photography and Fluorescein Angiography in Nonarteritic Anterior Ischemic Optic Neuropathy and Optic Neuritis.

    Science.gov (United States)

    Kim, Min Kyung; Kim, Ungsoo Samuel

    2016-08-01

    We evaluated fundus and fluorescein angiography (FAG) findings and characteristics that can help distinguish nonarteritic anterior ischemic optic neuropathy (NAION) from optic neuritis (ON). Twenty-three NAION patients and 17 ON with disc swelling patients were enrolled in this study. We performed fundus photography and FAG. The disc-swelling pattern, hyperemia grade, presence of splinter hemorrhages, cotton-wool spots, artery/vein ratio and degree of focal telangiectasia were investigated. The FAG findings for each patient were compared with respect to the following features: the pattern of disc leakage in the early phase, arteriovenous (artery/vein) transit time (second), and the presence and pattern of the filling delay. Cotton-wool spots, focal telangiectasia, and venous congestion were more common in the affected eyes of NAION patients. Upon FAG, 76.5% of the patients in the ON group exhibited normal choroidal circulation. However, 56.5% of patients in the NAION group demonstrated abnormal filling defects, such as peripapillary, generalized, or watershed zone filling delays. Fundus findings, including cotton-wool spots, focal telangiectasia, and venous congestion in the affected eye, may be clues that can be used to diagnose NAION. In addition, choroidal insufficiencies on FAG could be also helpful in differentiating NAION from ON.

  20. Modeling the problem of many hands in organisations

    NARCIS (Netherlands)

    Lima, de T.; Royakkers, L.M.M.; Dignum, F.P.M.; Coelho, H.; Studer, R.; Woodridge, M.J.

    2010-01-01

    In this paper we provide a formalism to reason about the problem of many hands in organisations. This is a problem that arises whenever the organisation is responsible for some undesirable outcome but none of its members can be held responsible for the outcome. The formalism proposed here is a logic

  1. Predictors for the progression of geographic atrophy in patients with age-related macular degeneration: fundus autofluorescence study with modified fundus camera.

    Science.gov (United States)

    Jeong, Y J; Hong, I H; Chung, J K; Kim, K L; Kim, H K; Park, S P

    2014-02-01

    We examined the association between abnormal fundus autofluorescence (FAF) features on images obtained by a modified fundus camera (mFC) and geographic atrophy (GA) progression in patients with age-related macular degeneration (AMD). Serial FAF images of 131 eyes from 131 patients with GA were included in the study. All FAF images were obtained with an mFC (excitation, ∼ 500-610 nm; emission, ∼ 675-715 nm). The GA area was quantified at baseline and 1 year later using a customized segmentation program. The yearly GA enlargement rate was then calculated. Abnormal FAF patterns in the junctional zone of GA were classified as None or Minimal change, Focal, Patchy, Banded, or Diffuse according to previously published classification based on confocal scanning laser ophthalmoscopy (cSLO). The relationship between GA enlargement and abnormal FAF was evaluated. The mean rate of GA enlargement was the fastest in eyes with Diffuse pattern (1.74 mm(2) per year), followed by eyes with the Banded pattern (1.69 mm(2) per year). Binary logistic regression analysis revealed that eyes with the Banded and Diffuse pattern had significantly higher risk for GA enlargement compared with eyes with the other patterns. FAF image obtained by mFC appears to be acceptable for evaluating GA in accordance with an established cSLO-based classification. Eyes with the Banded or the Diffuse patterns of abnormal FAF at baseline indicate a high risk for GA progression. Identifying patients at high risk for GA progression using an mFC is broadly available method that can provide additional information to help predict disease course.

  2. Hand Grasping Synergies As Biometrics.

    Science.gov (United States)

    Patel, Vrajeshri; Thukral, Poojita; Burns, Martin K; Florescu, Ionut; Chandramouli, Rajarathnam; Vinjamuri, Ramana

    2017-01-01

    Recently, the need for more secure identity verification systems has driven researchers to explore other sources of biometrics. This includes iris patterns, palm print, hand geometry, facial recognition, and movement patterns (hand motion, gait, and eye movements). Identity verification systems may benefit from the complexity of human movement that integrates multiple levels of control (neural, muscular, and kinematic). Using principal component analysis, we extracted spatiotemporal hand synergies (movement synergies) from an object grasping dataset to explore their use as a potential biometric. These movement synergies are in the form of joint angular velocity profiles of 10 joints. We explored the effect of joint type, digit, number of objects, and grasp type. In its best configuration, movement synergies achieved an equal error rate of 8.19%. While movement synergies can be integrated into an identity verification system with motion capture ability, we also explored a camera-ready version of hand synergies-postural synergies. In this proof of concept system, postural synergies performed well, but only when specific postures were chosen. Based on these results, hand synergies show promise as a potential biometric that can be combined with other hand-based biometrics for improved security.

  3. Hand Grasping Synergies As Biometrics

    Directory of Open Access Journals (Sweden)

    Ramana Vinjamuri

    2017-05-01

    Full Text Available Recently, the need for more secure identity verification systems has driven researchers to explore other sources of biometrics. This includes iris patterns, palm print, hand geometry, facial recognition, and movement patterns (hand motion, gait, and eye movements. Identity verification systems may benefit from the complexity of human movement that integrates multiple levels of control (neural, muscular, and kinematic. Using principal component analysis, we extracted spatiotemporal hand synergies (movement synergies from an object grasping dataset to explore their use as a potential biometric. These movement synergies are in the form of joint angular velocity profiles of 10 joints. We explored the effect of joint type, digit, number of objects, and grasp type. In its best configuration, movement synergies achieved an equal error rate of 8.19%. While movement synergies can be integrated into an identity verification system with motion capture ability, we also explored a camera-ready version of hand synergies—postural synergies. In this proof of concept system, postural synergies performed well, but only when specific postures were chosen. Based on these results, hand synergies show promise as a potential biometric that can be combined with other hand-based biometrics for improved security.

  4. Digital signal processing an experimental approach

    CERN Document Server

    Engelberg, Shlomo

    2008-01-01

    Digital Signal Processing is a mathematically rigorous but accessible treatment of digital signal processing that intertwines basic theoretical techniques with hands-on laboratory instruction. Divided into three parts, the book covers various aspects of the digital signal processing (DSP) ""problem."" It begins with the analysis of discrete-time signals and explains sampling and the use of the discrete and fast Fourier transforms. The second part of the book???covering digital to analog and analog to digital conversion???provides a practical interlude in the mathematical content before Part II

  5. Fundus autofluorescence in the diagnosis and monitoring of acute retinal necrosis

    OpenAIRE

    Ward, Tyson SJ; Reddy, Ashvini K

    2015-01-01

    Background Acute retinal necrosis (ARN), a vision threatening viral retinitis, is often diagnosed and treated based on clinical findings. These clinical features have been well characterized by various imaging modalities, but not using fundus autofluorescence (FAF), a noninvasive method of evaluating the neurosensory retina and retinal pigment epithelium (RPE) based on the detection of endogenous fluorophores. Findings A patient diagnosed with ARN was followed over a 10-month period to identi...

  6. Metadata, Cataloging, Digitization and Retrieval--Who's Doing What to Whom: The Colorado Digitization Project Experience.

    Science.gov (United States)

    Bishoff, Liz; Garrison, William A.

    This paper describes the experiences of the Colorado Digitization Project (CDP) related to accessing a diverse set of primary resources held by many different cultural heritage institutions. The CDP is a collaborative initiative involving Colorado's archives, historical societies, libraries, and museums. The CDP's goal is to create a virtual…

  7. Predicting meat quality traits of ovine m. semimembranosus, both fresh and following freezing and thawing, using a hand held Raman spectroscopic device.

    Science.gov (United States)

    Fowler, Stephanie M; Schmidt, Heinar; van de Ven, Remy; Wynn, Peter; Hopkins, David L

    2015-10-01

    Complementary studies were conducted to determine the potential for a Raman spectroscopic hand held device to predict meat quality traits of fresh lamb m. semimembranosus (topside) after ageing and freezing/thawing. Spectra were collected from 80 fresh muscles at 24h and 5d PM, another 80 muscles were measured at 24h, 5d and following freezing/thawing. Shear force, cooking loss, sarcomere length, colour, particle size, collagen content, pH24, pHu, purge and thaw loss were also measured. Results indicated a potential to predict pHu (R(2)cv=0.59), pH24 (R(2)cv=0.48) and purge (R(2)cv=0.42) using spectra collected 24h PM. L* could be predicted using spectra collected 24h (R(2)cv=0.33) or 5d PM (R(2)cv=0.33). This suggests that Raman spectroscopy is suited to identifying carcases which deviate from the normal metabolic processes and related meat quality traits. Copyright © 2015. Published by Elsevier Ltd.

  8. Contractile profile of esophageal and gastric fundus strips in experimental doxorubicin-induced esophageal atresia

    Directory of Open Access Journals (Sweden)

    F.A. Capeto

    2015-05-01

    Full Text Available Esophageal atresia (EA is characterized by esophageal and gastric motility changes secondary to developmental and postsurgical damage. This study evaluated the in vitro contractile profile of the distal esophagus and gastric fundus in an experimental model of EA induced by doxorubicin (DOXO. Wistar pregnant rats received DOXO 2.2 mg/kg on the 8th and 9th gestational days. On day 21.5, fetuses were collected, sacrificed, and divided into groups: control, DOXO without EA (DOXO-EA, and DOXO with EA (DOXO+EA. Strips from the distal esophagus and gastric fundus were mounted on a wire myograph and isolated organ-bath system, respectively, and subjected to increasing concentrations of carbamylcholine chloride (carbachol, CCh. The isolated esophagus was also stimulated with increasing concentrations of KCl. In esophagus, the concentration-effect curves were reduced in response to CCh in the DOXO+EA and DOXO-EA groups compared to the control group (P0.05. In response to KCl, the distal esophagus samples in the three groups were not statistically different with regard to Emax or EC50 values (P>0.05. No significant difference was noted for EC50 or Emax values in fundic strips stimulated with CCh (P>0.05. In conclusion, exposure of dams to DOXO during gestation inhibited the contractile behavior of esophageal strips from offspring in response to CCh but not KCl, regardless of EA induction. The gastric fundus of DOXO-exposed offspring did not have altered contractile responsiveness to cholinergic stimulation.

  9. Experimental OAI-Based Digital Library Systems

    Science.gov (United States)

    Nelson, Michael L. (Editor); Maly, Kurt (Editor); Zubair, Mohammad (Editor); Rusch-Feja, Diann (Editor)

    2002-01-01

    The objective of Open Archives Initiative (OAI) is to develop a simple, lightweight framework to facilitate the discovery of content in distributed archives (http://www.openarchives.org). The focus of the workshop held at the 5th European Conference on Research and Advanced Technology for Digital Libraries (ECDL 2001) was to bring researchers in the area of digital libraries who are building OAI based systems so as to share their experiences, problems they are facing, and approaches they are taking to address them. The workshop consisted of invited talks from well-established researchers working in building OAI based digital library system along with short paper presentations.

  10. Digital tool for detecting diabetic retinopathy in retinography image using gabor transform

    Science.gov (United States)

    Morales, Y.; Nuñez, R.; Suarez, J.; Torres, C.

    2017-01-01

    Diabetic retinopathy is a chronic disease and is the leading cause of blindness in the population. The fundamental problem is that diabetic retinopathy is usually asymptomatic in its early stage and, in advanced stages, it becomes incurable, hence the importance of early detection. To detect diabetic retinopathy, the ophthalmologist examines the fundus by ophthalmoscopy, after sends the patient to get a Retinography. Sometimes, these retinography are not of good quality. This paper show the implementation of a digital tool that facilitates to ophthalmologist provide better patient diagnosis suffering from diabetic retinopathy, informing them that type of retinopathy has and to what degree of severity is find . This tool develops an algorithm in Matlab based on Gabor transform and in the application of digital filters to provide better and higher quality of retinography. The performance of algorithm has been compared with conventional methods obtaining resulting filtered images with better contrast and higher.

  11. Unusual Fundus Autofluorescence Appearance in a Patient with Hydroxychloroquine Retinal Toxicity

    Directory of Open Access Journals (Sweden)

    Sleiman Abou-Ltaif

    2015-06-01

    Full Text Available Purpose: To report an unusual fundus autofluorescence aspect in a patient with suspected hydroxychloroquine retinal toxicity. Method: Case report of an unusual presentation of a patient treated for 9 consecutive years with a therapeutically recommended dose of hydroxychloroquine. Result: We report the case of a 53-year-old Caucasian female treated with 400 mg hydroxychloroquine for rheumatoid arthritis over 9 years, currently on methotrexate and folinic acid, who stopped treatment 3 years ago. The cumulative dose is estimated at 1.314 kg. She recently noticed a reduction of vision in both eyes to 0.34 logMAR, with colour vision problems and major distortion in central vision. Fundus autofluorescence revealed minimal foveal pigmentary changes and more pronounced changes in the retina elsewhere. Foveal changes were confirmed by optical coherence tomography in both eyes. The patient did not report any colour perception difficulties or night vision problems and has no family history of any eye condition. Her visual field tested by an optician was full, with some central changes. Conclusion: Retinal toxicity from hydroxychloroquine can present in a different aspect than the commonly known retinal toxicity, and it happens even after years of cessation of the drug. The role of cumulative dose in toxicity is supported in this paper.

  12. Wide-field fundus autofluorescence corresponds to visual fields in chorioretinitis patients

    Directory of Open Access Journals (Sweden)

    Seidensticker F

    2011-11-01

    Full Text Available Florian Seidensticker1, Aljoscha S Neubauer1, Tamer Wasfy1,2, Carmen Stumpf1, Stephan R Thurau1,*, Anselm Kampik1, Marcus Kernt1,*1Department of Ophthalmology, Ludwig-Maximilians-University, Munich, Germany; 2Department of Ophthalmology, Tanta University, Tanta, Egypt *Both authors contributed equally to this workBackground and objectives: Detection of peripheral fundus autofluorescence (FAF using conventional scanning laser ophthalmoscopes (SLOs is difficult and requires pupil dilation. Here we evaluated the diagnostic properties of wide-field FAF detected by a two-laser wavelength wide-field SLO in uveitis patients.Study design/materials and methods: Observational case series of four patients suffering from different types of posterior uveitis/chorioretinitis. Wide-field FAF images were compared to visual fields. Panretinal FAF was detected by a newly developed SLO, which allows FAF imaging of up to 200° of the retina in one scan without the need for pupil dilation. Visual fields were obtained by Goldmann manual perimetry.Results: Findings from wide-field FAF imaging showed correspondence to visual field defects in all cases.Conclusion: Wide-field FAF allowed the detection of visual field defect-related alterations of the retinal pigment epithelium in all four uveitis cases.Keywords: fundus autofluorescence (FAF, Optomap, wide-field scanning laser ophthalmoscopy, imaging, uveitis, visual field

  13. Bimanual proprioception: are two hands better than one?

    NARCIS (Netherlands)

    Wong, J.D.; Wilson, E.T.; Kistemaker, D.A.; Gribble, P.L.

    2014-01-01

    Information about the position of an object that is held in both hands, such as a golf club or a tennis racquet, is transmitted to the human central nervous system from peripheral sensors in both left and right arms. How does the brain combine these two sources of information? Using a robot to move

  14. Application of Optical Coherence Tomography and Contrast Sensitivity Test for Observing Fundus Changes of Patients With Pregnancy-Induced Hypertension Syndrome.

    Science.gov (United States)

    Wang, Zhixue; Zou, Yuanyuan; Li, Wenying; Wang, Xueyan; Zhang, Min; Wang, Wenying

    2015-11-01

    This study was aimed to investigate the fundus changes of patients with pregnancy-induced hypertension syndrome (PIHS) using optical coherence tomography (OCT) technology and contrast sensitivity (CS) tests.Ninety-eight patients with PIHS underwent routine eye examinations including vision correction, fundus examination, OCT, and CS tests. The CS test was performed at low, medium, and high frequency, respectively. Moreover, the difference in CS tests between 2 groups was analyzed by independent-samples T test. The Kruskal-Wallis rank sum test and linear regression model were used to detect the correlation of OCT with CS, respectively. Meanwhile Satterthwaite approximate T test was adopted for pairwise comparisons after nonparametric analysis of variance.The OCT test revealed that 56.76% of the examined eyes showed shallow retinal detachment in the macula lutea and around the optic disk. The differences in CS at each spatial frequency between the case and control group were statistically significant (P tests might be valuable methods in observing fundus changes for PIHS patients.

  15. Circuit For Control Of Electromechanical Prosthetic Hand

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1995-01-01

    Proposed circuit for control of electromechanical prosthetic hand derives electrical control signals from shoulder movements. Updated, electronic version of prosthesis, that includes two hooklike fingers actuated via cables from shoulder harness. Circuit built around favored shoulder harness, provides more dexterous movement, without incurring complexity of computer-controlled "bionic" or hydraulically actuated devices. Additional harness and potentiometer connected to similar control circuit mounted on other shoulder. Used to control stepping motor rotating hand about prosthetic wrist to one of number of angles consistent with number of digital outputs. Finger-control signals developed by circuit connected to first shoulder harness transmitted to prosthetic hand via sliprings at prosthetic wrist joint.

  16. Technology Knowledge Self-Assessment and Pre-Test Performance among Digital Natives

    Science.gov (United States)

    Nelms, Keith R.

    2015-01-01

    According to education pundits, traditional-age college students are "digital natives" inherently savvy in digital technology due to their constant exposure to technology from an early age. This widely held meme is at odds with observation in the college classroom. In this research, college students in an introductory information…

  17. Automatic Segmentation of Optic Disc in Eye Fundus Images: A Survey

    OpenAIRE

    Allam, Ali; Youssif, Aliaa; Ghalwash, Atef

    2015-01-01

    Optic disc detection and segmentation is one of the key elements for automatic retinal disease screening systems. The aim of this survey paper is to review, categorize and compare the optic disc detection algorithms and methodologies, giving a description of each of them, highlighting their key points and performance measures. Accordingly, this survey firstly overviews the anatomy of the eye fundus showing its main structural components along with their properties and functions. Consequently,...

  18. Concept of digital nomad: fundamental risks of digital economy development

    Directory of Open Access Journals (Sweden)

    Elena Lyudvigovna Iakovleva

    2017-12-01

    Full Text Available Objective to identify the key risks of the digital economy development. Methods abstractlogical and dialectical methods. Results a modern individual cannot imagine their life without digital devices which facilitate their functioning and enable them to be included into the virtual space. The role of digital economy in the changes in all spheres of human life is analyzed in the article. With the growing role of the digital economy the approaches to business models formation are changing as well as the role of digital assets. This also leads to the transformation of human behavior the new risks of the digital economy accelerated development. In this regard the article characterizes an individual as a digital nomad defines the features of their behavior in the socioeconomic environment and highlights the main risks that arise in connection with digital nomadism. It is determined that one of the most characteristic features of a modern person is hypermobility eparkourism. In addition the paper describes the problems of anonymity in virtual space and the emergence of systems that provide anonymity of the individual as well as the risks arising in connection with that. The problem of lack of culture and value systems in the virtual space is highlighted as well the problem of developing contradictions in information leading to the alienation of people from the real world. It was determined that the informatization of economy on the one hand leads to faster business processes reduced transaction costs saving of variable costs due to robotization of production and on the other hand it leads to the transformation of competition growth of tension in society in connection with the job cuts. Another problem is personal and national security associated with the development of social networks the developers of which are other countries and also with the emergence of mechanisms of influence on mass consciousness. Scientific novelty it is shown that the risks

  19. Dense Fully Convolutional Segmentation of the Optic Disc and Cup in Colour Fundus for Glaucoma Diagnosis

    Directory of Open Access Journals (Sweden)

    Baidaa Al-Bander

    2018-03-01

    Full Text Available Glaucoma is a group of eye diseases which can cause vision loss by damaging the optic nerve. Early glaucoma detection is key to preventing vision loss yet there is a lack of noticeable early symptoms. Colour fundus photography allows the optic disc (OD to be examined to diagnose glaucoma. Typically, this is done by measuring the vertical cup-to-disc ratio (CDR; however, glaucoma is characterised by thinning of the rim asymmetrically in the inferior-superior-temporal-nasal regions in increasing order. Automatic delineation of the OD features has potential to improve glaucoma management by allowing for this asymmetry to be considered in the measurements. Here, we propose a new deep-learning-based method to segment the OD and optic cup (OC. The core of the proposed method is DenseNet with a fully-convolutional network, whose symmetric U-shaped architecture allows pixel-wise classification. The predicted OD and OC boundaries are then used to estimate the CDR on two axes for glaucoma diagnosis. We assess the proposed method’s performance using a large retinal colour fundus dataset, outperforming state-of-the-art segmentation methods. Furthermore, we generalise our method to segment four fundus datasets from different devices without further training, outperforming the state-of-the-art on two and achieving comparable results on the remaining two.

  20. Second to fourth digit ratio, sex differences and antropometric measuments: their relationship in children.

    Science.gov (United States)

    Uludag, Aysegul; Tekin, Murat; Ertekin, Yusuf H; Şahin, Erkan M; Cevizci, Sibel; Cibik, Birol; Oguz, Sevilay; Erbag, Oznur

    2017-04-01

    The aim of this study was to determine the effect of socio-demographic factors and anthropometric measurements on 2/4 digit ratio in the school aged children. This cross-sectional study was completed in primary and secondary schools in the city center of Canakkale, Turkey. The students were seated at a table by the responsible doctor, and were asked to extend the palm of the right and left hand in the schools. Using a Vernier Caliper the 2/4 fingers were measured from the palm twice, and the results were noted together with socio-demographic information. Weight, length, waist and hip measurements were taken while students were behind a folding screen. A total of 1860 students from 5-14 years were included in the study. The right hand 2/4 digit ratio was 0.9765±0.035 and the left hand ratio was 0.9716±0.036 for girls. For the boys the ratios were 0.9688±0.035 for right hand and 0.9653±0.033 for left hand. The digit ratios of girls were significantly higher than boys and the right hand ratio was even greater. The 2/4 digit measurements of both hands of students were positively correlated with each other. In regression model left hand 2/4 ratio is dependent hip circumference, monthly income and gender as adjusted r2 0.051. The right hand 2/4 ratio was dependent gender, monthly income, hip circumference and birthweight as adjusted r2 0.041. The 2/4 digit ratio of school-aged in Turkish children differed based on gender. Digit ratios depend on the hip circumference, gender (girls have higher ratio), birthweight, gestation week and monthly income. Further research, especially the effect of monthly income, is needed.

  1. Rapid grading of fundus photographs for diabetic retinopathy using crowdsourcing.

    Science.gov (United States)

    Brady, Christopher J; Villanti, Andrea C; Pearson, Jennifer L; Kirchner, Thomas R; Gupta, Omesh P; Shah, Chirag P

    2014-10-30

    Screening for diabetic retinopathy is both effective and cost-effective, but rates of screening compliance remain suboptimal. As screening improves, new methods to deal with screening data may help reduce the human resource needs. Crowdsourcing has been used in many contexts to harness distributed human intelligence for the completion of small tasks including image categorization. Our goal was to develop and validate a novel method for fundus photograph grading. An interface for fundus photo classification was developed for the Amazon Mechanical Turk crowdsourcing platform. We posted 19 expert-graded images for grading by Turkers, with 10 repetitions per photo for an initial proof-of-concept (Phase I). Turkers were paid US $0.10 per image. In Phase II, one prototypical image from each of the four grading categories received 500 unique Turker interpretations. Fifty draws of 1-50 Turkers were then used to estimate the variance in accuracy derived from randomly drawn samples of increasing crowd size to determine the minimum number of Turkers needed to produce valid results. In Phase III, the interface was modified to attempt to improve Turker grading. Across 230 grading instances in the normal versus abnormal arm of Phase I, 187 images (81.3%) were correctly classified by Turkers. Average time to grade each image was 25 seconds, including time to review training images. With the addition of grading categories, time to grade each image increased and percentage of images graded correctly decreased. In Phase II, area under the curve (AUC) of the receiver-operator characteristic (ROC) indicated that sensitivity and specificity were maximized after 7 graders for ratings of normal versus abnormal (AUC=0.98) but was significantly reduced (AUC=0.63) when Turkers were asked to specify the level of severity. With improvements to the interface in Phase III, correctly classified images by the mean Turker grade in four-category grading increased to a maximum of 52.6% (10/19 images

  2. Force-directed design of a voluntary closing hand prosthesis

    NARCIS (Netherlands)

    De Visser, H.; Herder, J.L.

    2000-01-01

    This paper presents the design of a body-powered voluntary closing prosthetic hand. It is argued that the movement of the fingers before establishing a grip is much less relevant for good control of the object held than the distribution of forces once the object has been contacted. Based on this

  3. Automatic multiresolution age-related macular degeneration detection from fundus images

    Science.gov (United States)

    Garnier, Mickaël.; Hurtut, Thomas; Ben Tahar, Houssem; Cheriet, Farida

    2014-03-01

    Age-related Macular Degeneration (AMD) is a leading cause of legal blindness. As the disease progress, visual loss occurs rapidly, therefore early diagnosis is required for timely treatment. Automatic, fast and robust screening of this widespread disease should allow an early detection. Most of the automatic diagnosis methods in the literature are based on a complex segmentation of the drusen, targeting a specific symptom of the disease. In this paper, we present a preliminary study for AMD detection from color fundus photographs using a multiresolution texture analysis. We analyze the texture at several scales by using a wavelet decomposition in order to identify all the relevant texture patterns. Textural information is captured using both the sign and magnitude components of the completed model of Local Binary Patterns. An image is finally described with the textural pattern distributions of the wavelet coefficient images obtained at each level of decomposition. We use a Linear Discriminant Analysis for feature dimension reduction, to avoid the curse of dimensionality problem, and image classification. Experiments were conducted on a dataset containing 45 images (23 healthy and 22 diseased) of variable quality and captured by different cameras. Our method achieved a recognition rate of 93:3%, with a specificity of 95:5% and a sensitivity of 91:3%. This approach shows promising results at low costs that in agreement with medical experts as well as robustness to both image quality and fundus camera model.

  4. Myelopathy hand in cervical radiculopathy

    International Nuclear Information System (INIS)

    Hosono, Noboru; Mukai, Yoshihiro; Takenaka, Shota; Fuji, Takeshi; Sakaura, Hironobu; Miwa, Toshitada; Makino, Takahiro

    2010-01-01

    The so-called 'myelopathy hand', or characteristic finger paralysis, often recognized in cervical compression myelopathy, has been considered a unique manifestation of cervical myelopathy. We used our original grip and release test, a 15-second test in which finger motion is captured with a digital camera, to investigate whether cervical radiculopathy has the same characteristics as myelopathy hand. Thirty patients with pure radiculopathy, id est (i.e.), who had radiating arm pain and evidence of corresponding nerve root impingement on X-ray images or MRI scans, but did not have spinal cord compression, served as the subjects. In contrast to other radiculopathies, C7 radiculopathy was manifested by a significant reduction in the number of finger motion cycles on the affected side in comparison with the unaffected side, the same as in myelopathy hand. Uncoordinated finger motion was significantly more frequent on the affected side in C6 radiculopathy than on the unaffected side. These findings contradict the conventional notion that myelopathy hand is a unique manifestation of cervical myelopathy, but some radiculopathies manifested the same kinds of finger paralysis observed in myelopathy hand. (author)

  5. Development of PIC-based digital survey meter

    International Nuclear Information System (INIS)

    Nor Arymaswati Abdullah; Nur Aira Abdul Rahman; Mohd Ashhar Khalid; Taiman Kadni; Glam Hadzir Patai Mohamad; Abd Aziz Mhd Ramli; Chong Foh Yong

    2006-01-01

    The need of radiation monitoring and monitoring of radioactive contamination in the workplace is very important especially when x-ray machines, linear accelerators, electron beam machines and radioactive sources are present. The appropriate use of radiation detector is significant in order to maintain a radiation and contamination free workplace. This paper reports on the development of a prototype of PIC-based digital survey meter. This prototype of digital survey meter is a hand held instrument for general-purpose radiation monitoring and surface contamination meter. Generally, the device is able to detect some or all of the three major types of ionizing radiation, namely alpha, beta and gamma. It uses a Geiger-Muller tube as a radiation detector, which converts gamma radiation quanta to electric pulses and further processed by the electronic devices. The development involved the design of the controller, counter and high voltage circuit. All these circuit are assembled and enclosed in a plastic casing together with a GM detector and LCD display to form a prototype survey meter. The number of counts of the pulses detected by the survey meter varies due to the random nature of radioactivity. By averaging the reading over a time-period, more accurate and stable reading is achieved. To test the accuracy and the linearity of the design, the prototype was calibrated using standard procedure at the Secondary Standard Dosimetry Laboratory (SSDL) in MINT. (Author)

  6. Digital Materia

    OpenAIRE

    Lindgren, Marcus; Richey, Emma

    2014-01-01

    Med tankar från pedagogen Montessori och filosoferna Platon och Baudrillard har detta arbete behandlat frågor om datorn och dess betydelse för en grafiker. Frågeställningen formulerades efter hand och lydde tillslut: ”Hur kan materia te sig i digital form?” Forskningen resulterade i en hypotes för hur digital materia skulle födas i datorn: genom att blanda två uppsättningar av data, såsom två genuppsättningar tillsammans skapar en ny organism. Under produktionen utvecklades därmed en metod fö...

  7. CORRELATION OF FUNDUS CHANGES IN RELATION TO REFRACTIVE ERROR IN PATIENTS WITH MYOPIA- A CLINICAL PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Balasubramanian M. Manickavelu

    2018-01-01

    Full Text Available BACKGROUND Retina is unique among the complex element of the central nervous system and the special senses. It may be readily viewed during life and it is sufficiently transparent, so that alterations within and adjacent to it may be observed in vivo. The peripheral retina owing to its thinness comparing to that of the central part, poorly-developed retinal cells, absence of large blood vessels, relatively insensitive to light, less resistance to traction, forms a seat for various lesions, which are potentially dangerous for the vision. It is in myopia that we meet the most frequent and the most obvious anomalies in the fundus changes, which bear some relation to the degree of myopia and appeal to be concerned with it either as a cause or effect or perhaps both. The aim of our study is to correlate fundus changes in relation to refractive error in patients with myopia. MATERIALS AND METHODS In our study, 100 cases of myopic (-6D:50 cases patients were selected. Detailed evaluation done. History of refractive error includes duration, age at which spectacles were worn for the first time. Time of last change of spectacles, family history of myopia, history of other symptoms like progressive loss of vision, defective vision related to day or night, sudden loss of vision, flashes and floaters. Anterior segment was examined followed by the recording of initial visual acuity and the best corrected visual acuity was noted. IOP was measured for all the cases using Schiotz tonometry. Axial length was measured in all the cases. Fundus examined with direct ophthalmoscope, indirect ophthalmoscope, 3 mirror and 90D lens. Bscan was done in few cases. The media, disc, vessels, macula and the surrounding retina were examined. The periphery was examined with indentation method. The various fundus features and pathological lesions in different degrees of myopia were noted. RESULTS Females were comparatively more affected. Highest incidence was seen in the younger

  8. [Fundus autofluorescence in patients with inherited retinal diseases : Patterns of fluorescence at two different wavelengths.

    NARCIS (Netherlands)

    Theelen, T.; Boon, C.J.F.; Klevering, B.J.; Hoyng, C.B.

    2008-01-01

    BACKGROUND: Fundus autofluorescence (FAF) may be excited and measured at different wavelengths. In the present study we compared short wavelength and near-infrared FAF patterns of retinal dystrophies. METHODS: We analysed both eyes of 108 patients with diverse retinal dystrophies. Besides colour

  9. Eccentric and isometric shoulder rotator cuff strength testing using a hand-held dynamometer: reference values for overhead athletes.

    Science.gov (United States)

    Cools, Ann M J; Vanderstukken, Fran; Vereecken, Frédéric; Duprez, Mattias; Heyman, Karel; Goethals, Nick; Johansson, Fredrik

    2016-12-01

    In order to provide science-based guidelines for injury prevention or return to play, regular measurement of isometric and eccentric internal (IR) and external (ER) rotator strength is warranted in overhead athletes. However, up to date, no normative database exists regarding these values, when measured with a hand-held dynamometer. Therefore, the purpose of the study was to provide a normative database on isometric and eccentric rotator cuff (RC) strength values in a sample of overhead athletes, and to discuss gender, age and sports differences. A HHD was used to measure RC strength in 201 overhead athletes between 18 and 50 years old from three different sports disciplines: tennis, volleyball and handball. Isometric as well as eccentric strength was measured in different shoulder positions. Outcome variables of interest were isometric ER and IR strength, eccentric ER strength, and intermuscular strength ratios ER/IR. Our results show significant side, gender and sports discipline differences in the isometric and eccentric RC strength. However, when normalized to body weight, gender differences often are absent. In general, strength differences are in favour of the dominant side, the male athletes and handball. Intermuscular ER/IR ratios showed gender, sports, and side differences. This normative database is necessary to help the clinician in the evaluation of RC strength in healthy and injured overhead athletes. In view of the preventive screening and return-to-play decisions in overhead athletes, normalization to body weight and calculating intermuscular ratios are key points in this evaluation. Diagnostic study, Level III.

  10. Comparison of optic area measurement using fundus photography and optical coherence tomography between optic nerve head drusen and control subjects.

    Science.gov (United States)

    Flores-Rodríguez, Patricia; Gili, Pablo; Martín-Ríos, María Dolores; Grifol-Clar, Eulalia

    2013-03-01

    To compare optic disc area measurement between optic nerve head drusen (ONHD) and control subjects using fundus photography, time-domain optical coherence tomography (TD-OCT) and spectral-domain optical coherence tomography (SD-OCT). We also made a comparison between each of the three techniques. We performed our study on 66 eyes (66 patients) with ONHD and 70 healthy control subjects (70 controls) with colour ocular fundus photography at 20º (Zeiss FF 450 IR plus), TD-OCT (Stratus OCT) with the Fast Optic Disc protocol and SD-OCT (Cirrus OCT) with the Optic Disc Cube 200 × 200 protocol for measurement of the optic disc area. The measurements were made by two observers and in each measurement a correction of the image magnification factor was performed. Measurement comparison using the Student's t-test/Mann-Whitney U test, the intraclass correlation coefficient, Pearson/Spearman rank correlation coefficient and the Bland-Altman plot was performed in the statistical analysis. Mean and standard deviation (SD) of the optic disc area in ONHD and in controls was 2.38 (0.54) mm(2) and 2.54 (0.42) mm(2), respectively with fundus photography; 2.01 (0.56) mm(2) and 1.66 (0.37) mm(2), respectively with TD-OCT, and 2.03 (0.49) mm(2) and 1.75 (0.38) mm(2), respectively with SD-OCT. In ONHD and controls, repeatability of optic disc area measurement was excellent with fundus photography and optical coherence tomography (TD-OCT and SD-OCT), but with a low degree of agreement between both techniques. Optic disc area measurement is smaller in ONHD compared to healthy subjects with fundus photography, unlike time-domain and spectral-domain optical coherence tomography in which the reverse is true. Both techniques offer good repeatability, but a low degree of correlation and agreement, which means that optic disc area measurement is not interchangeable or comparable between techniques. Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  11. Investigating the influence of chromatic aberration and optical illumination bandwidth on fundus imaging in rats

    Science.gov (United States)

    Li, Hao; Liu, Wenzhong; Zhang, Hao F.

    2015-10-01

    Rodent models are indispensable in studying various retinal diseases. Noninvasive, high-resolution retinal imaging of rodent models is highly desired for longitudinally investigating the pathogenesis and therapeutic strategies. However, due to severe aberrations, the retinal image quality in rodents can be much worse than that in humans. We numerically and experimentally investigated the influence of chromatic aberration and optical illumination bandwidth on retinal imaging. We confirmed that the rat retinal image quality decreased with increasing illumination bandwidth. We achieved the retinal image resolution of 10 μm using a 19 nm illumination bandwidth centered at 580 nm in a home-built fundus camera. Furthermore, we observed higher chromatic aberration in albino rat eyes than in pigmented rat eyes. This study provides a design guide for high-resolution fundus camera for rodents. Our method is also beneficial to dispersion compensation in multiwavelength retinal imaging applications.

  12. Hand-held optical sensor using denatured antibody coated electro-active polymer for ultra-trace detection of copper in blood serum and environmental samples.

    Science.gov (United States)

    Chandra, Sutapa; Dhawangale, Arvind; Mukherji, Soumyo

    2018-07-01

    An optimum copper concentration in environment is highly desired for all forms of life. We have developed an ultrasensitive copper sensor which functions from femto to micro molar concentration accurately (R 2 = 0.98). The sensor is based on denatured antibody immunoglobulin G (IgG), immobilized on polyaniline (PAni) which in turn is the coating on the core of an optical fiber. The sensing relies on changes in evanescent wave absorbance in the presence of the analyte. The sensor showed excellent selectivity towards Cu (II) ions over all other metal ions. The sensor was tested with lake and marine water samples to determine unknown concentrations of copper ions and the recovery results were within 90-115%, indicating reasonable accuracy. We further integrated the fiber-optic sensor with a miniaturized hand-held instrumentation platform to develop an accurate and field deployable device which can broadly be applicable to determine Cu (II) concentration in a wide range of systems - natural water bodies, soil as well as blood serum. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Interactions between Digital Geometry and Combinatorics on Words

    Directory of Open Access Journals (Sweden)

    Srečko Brlek

    2011-08-01

    Full Text Available We review some recent results in digital geometry obtained by using a combinatorics on words approach to discrete geometry. Motivated on the one hand by the well-known theory of Sturmian words which model conveniently discrete lines in the plane, and on the other hand by the development of digital geometry, this study reveals strong links between the two fields. Discrete figures are identified with polyominoes encoded by words. The combinatorial tools lead to elegant descriptions of geometrical features and efficient algorithms. Among these, radix-trees are useful for efficiently detecting path intersection, Lyndon and Christoffel words appear as the main tools for describing digital convexity; equations on words allow to better understand tilings by translations.

  14. Left hand polydactyly: a case report.

    Science.gov (United States)

    Mumoli, Nicola; Gandini, Daniele; Wamala, Edris Kalanzi; Cei, Marco

    2008-11-24

    Polydactyly is a congenital anomaly with a wide range of manifestations that occurs in many forms, ranging from varying degrees of mere splitting to completely duplicated thumb. When duplication occurs alone, it is usually unilateral and sporadic. In this case report we describe an otherwise healthy 19-year-old woman of Tibetan heritage with isolated left hand preaxial polydactyly. She experienced working related difficulties in her daily yak's milking. She subsequently underwent surgical correction, and the over number thumb was removed with associated meticulous skeletal and soft tissue reconstruction. Polydactyly is the most common congenital digital anomaly of the hand and foot. It can occur in isolation or as part of a syndrome. Surgery is necessary to create a single, functioning thumb and is indicated to improve cosmesis. Skin, nail, bone, ligament, and musculoskeletal elements must be combined to reconstruct an optimal digit. In this case (Tibetan society is almost exclusively a sheep-breeding one) surgery was necessary to leave a single, functioning thumb for her work as yak milkmaid.

  15. CERN-UNESCO School on Digital Libraries

    CERN Multimedia

    2016-01-01

    The CERN-UNESCO School on Digital libraries 2016 was held in Kumasi, Ghana, from 28th November to 2nd December 2016. The school was organized by the United Nations Educational, Scientific and Cultural Organization (UNESCO) and the European Organization for Nuclear Research (CERN) and was hosted by Kwame Nkrumah University of Science and Technology. The purpose of the school was to deepen the participants’ understanding of digital libraries, expose new trends in scientific publishing and emphasize a set of principles related to open access, both for data and publications.

  16. Bright Retinal Lesions Detection using Colour Fundus Images Containing Reflective Features

    Energy Technology Data Exchange (ETDEWEB)

    Giancardo, Luca [ORNL; Karnowski, Thomas Paul [ORNL; Chaum, Edward [ORNL; Meriaudeau, Fabrice [ORNL; Tobin Jr, Kenneth William [ORNL; Li, Yaquin [University of Tennessee, Knoxville (UTK)

    2009-01-01

    In the last years the research community has developed many techniques to detect and diagnose diabetic retinopathy with retinal fundus images. This is a necessary step for the implementation of a large scale screening effort in rural areas where ophthalmologists are not available. In the United States of America, the incidence of diabetes is worryingly increasing among the young population. Retina fundus images of patients younger than 20 years old present a high amount of reflection due to the Nerve Fibre Layer (NFL), the younger the patient the more these reflections are visible. To our knowledge we are not aware of algorithms able to explicitly deal with this type of reflection artefact. This paper presents a technique to detect bright lesions also in patients with a high degree of reflective NFL. First, the candidate bright lesions are detected using image equalization and relatively simple histogram analysis. Then, a classifier is trained using texture descriptor (Multi-scale Local Binary Patterns) and other features in order to remove the false positives in the lesion detection. Finally, the area of the lesions is used to diagnose diabetic retinopathy. Our database consists of 33 images from a telemedicine network currently developed. When determining moderate to high diabetic retinopathy using the bright lesions detected the algorithm achieves a sensitivity of 100% at a specificity of 100% using hold-one-out testing.

  17. Automatic Drusen Quantification and Risk Assessment of Age-related Macular Degeneration on Color Fundus Images

    NARCIS (Netherlands)

    Grinsven, M.J.J.P. van; Lechanteur, Y.T.E.; Ven, J.P.H. van de; Ginneken, B. van; Hoyng, C.B.; Theelen, T.; Sanchez, C.I.

    2013-01-01

    PURPOSE: To evaluate a machine learning algorithm that allows for computer aided diagnosis (CAD) of non-advanced age-related macular degeneration (AMD) by providing an accurate detection and quantification of drusen location, area and size. METHODS: Color fundus photographs of 407 eyes without AMD

  18. Evaluating the transmitted vibration to operator′s hands hand and effect of protective gloves in real condition, based on International Standard Organization 5349 standard

    Directory of Open Access Journals (Sweden)

    Farhad Forouharmajd

    2016-01-01

    Full Text Available Aims: The objective of this research was an evaluation of hand-held tools vibration acceleration such as circular saw and drill transmitted to operator′s and also to determine the role of glove in vibration reduction of those tools. Materials and Methods: In this study, Bruel and Kjaer Vibration meter with a model of 2231 and its analyzer, 2522, along three types of gloves have been used. Accelerometer transducer installed according to International Standard Organization (ISO 5349:1-2 standards in the case of the operator handles the hand-held tool. In next step, the transducer was placed inside the glove. Results: The results show the most accelerated vibration in axis Y for circular saw while working on Plexiglas. All of the used gloves show a reduction of vibration transmission from tools to hands. Glove of C grouped had a reduction of vibration less than two other groups. Conclusion: Based on ISO 5349-1, 10% of workers who are working with circular saw and drill without using glove will be affiliated to white finger after about 7-12 years. As a whole, the results showed that the anti-vibration gloves should be tested in real conditions before using them.

  19. Magnified Bacteria Powerful Motivator for Hand Hygiene Compliance.

    Science.gov (United States)

    Gregory, Ashley

    2016-08-01

    Infection prevention specialists at Henry Ford Hospital in Detroit have found that showing healthcare workers magnified pictures of bacteria found ontheir hands and in their surrounding units can be a powerful motivator for improved hand hygiene compliance. When tested in four units during a one-month period, the intervention boosted hand hygiene compliance by an average of 24%. Investigators note that to be successful, the intervention must be paired with an effective compliance monitoring program. For the study, investigators visited each unit twice per week, during which they would swab various items as well as employees' hands using and adenosine triphosphate (ATP) meter, a hand-held device that measures living organisms. During each unit visit, infection prevention specialists would show unit personnel pictures from a compilation of 12 magnified images of bacteria that had been lifted from the unit. This was to demonstrate what the bacteria would look like under a microscope. The unsavory pictures produced immediate increases in had hygiene compliance, and prompted healthcare workers to see who could produce the best ATP meter readings on subsequent infection prevention specialist visits.

  20. Field studies on health effects from the application of two organophosphorus insecticide formulations by hand-held ULV to cotton.

    Science.gov (United States)

    Kummer, R; van Sittert, N J

    1986-10-01

    Two field studies to assess the health implications for farmers applying two different formulations containing organophosphorus (OP) pesticides to cotton by hand-held ULV are described. The first study, carried out in the Ivory Coast, involved the application of an endrin/DDT/methylparathion (MEP) formulation in an aromatic hydrocarbon solvent. The second study took place in Indonesia with a 20% monocrotophos formulation in a mixture of a glycol and a glycol ether. Both studies were carried out under actual field conditions. The purpose of the studies was to get a good assessment of the health hazards of the particular formulation, used under the specific circumstances and agronomic requirements of the area of application and taking into account all local, climatic and cultural conditions that could be of possible influence. The results showed that in both studies skin exposures took place during application and especially during handling, filling and cleaning, and that inhalation of spray mist was negligible. Absorption was confirmed by the presence in urine of metabolites of endrin and methylparathion in the Ivory Coast study, and of dimethyl phosphate in the Indonesia study. No clinical signs or symptoms of intoxication were discovered in either study, nor were inhibitions of cholinesterase (ChE) activity of health significance established under the conditions of the studies. In addition, various practical aspects such as choice of apparatus, of formulation, the application procedures etc. are discussed.

  1. Modified submucosal tunneling endoscopic resection for submucosal tumors in the esophagus and gastric fundus near the cardia.

    Science.gov (United States)

    Zhang, Qiang; Cai, Jian-Qun; Xiang, Li; Wang, Zhen; de Liu, Si; Bai, Yang

    2017-08-01

    Background and study aims  Submucosal tunneling endoscopic resection with double opening (DO-STER) was developed by our group for the resection of submucosal tumors in the esophagus and gastric fundus near the cardia. This study aimed to provide a preliminary evaluation of feasibility and safety of DO-STER. Methods  The key to DO-STER is the creation of a tunnel opening in the mucosa over the inferior border of the tumor. During resection, the tumor can be gradually pushed out of the submucosal tunnel through the opening, leaving enough space for operation within the tunnel. A total of 10 tumors resected by DO-STER were retrospectively reviewed. Results  All tumors were successfully resected by DO-STER. One tumor was located at the lower esophagus, four at the esophagogastric junction, and five at the gastric fundus near the cardia. Tumor size ranged from 1.0 × 1.2 cm to 3.5 × 5.0 cm, and all tumors originated from the muscularis propria. Operative times ranged from 45 to 150 minutes. No delayed bleeding or perforation occurred. Conclusion DO-STER seems to provide an alternative approach for resection of tumors in the esophagus and gastric fundus near the cardia. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Quantitative impact of direct, personal feedback on hand hygiene technique.

    Science.gov (United States)

    Lehotsky, Á; Szilágyi, L; Ferenci, T; Kovács, L; Pethes, R; Wéber, G; Haidegger, T

    2015-09-01

    This study investigated the effectiveness of targeting hand hygiene technique using a new training device that provides objective, personal and quantitative feedback. One hundred and thirty-six healthcare workers in three Hungarian hospitals participated in a repetitive hand hygiene technique assessment study. Ultraviolet (UV)-labelled hand rub was used at each event, and digital images of the hands were subsequently taken under UV light. Immediate objective visual feedback was given to participants, showing missed areas on their hands. The rate of inadequate hand rubbing reduced from 50% to 15% (P < 0.001). However, maintenance of this reduced rate is likely to require continuous use of the electronic equipment. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  3. Quantitative Fundus Autofluorescence in Best Vitelliform Macular Dystrophy: RPE Lipofuscin is not Increased in Non-Lesion Areas of Retina.

    Science.gov (United States)

    Sparrow, Janet R; Duncker, Tobias; Woods, Russell; Delori, François C

    2016-01-01

    Since the lipofuscin of retinal pigment epithelial (RPE) cells has been implicated in the pathogenesis of Best vitelliform macular dystrophy, we quantified fundus autofluorescence (quantitative fundus autofluorescence, qAF) as an indirect measure of RPE lipofuscin levels. Mean non-lesion qAF was found to be within normal limits for age. By spectral domain optical coherence tomography (SD-OCT) vitelliform lesions presented as fluid-filled subretinal detachments containing reflective material. We discuss photoreceptor outer segment debris as the source of the intense fluorescence of these lesions and loss of anion channel functioning as an explanation for the bullous photoreceptor-RPE detachment. Unexplained is the propensity of the disease for central retina.

  4. Right-handed fossil humans.

    Science.gov (United States)

    Lozano, Marina; Estalrrich, Almudena; Bondioli, Luca; Fiore, Ivana; Bermúdez de Castro, José-Maria; Arsuaga, Juan Luis; Carbonell, Eudald; Rosas, Antonio; Frayer, David W

    2017-11-01

    Fossil hominids often processed material held between their upper and lower teeth. Pulling with one hand and cutting with the other, they occasionally left impact cut marks on the lip (labial) surface of their incisors and canines. From these actions, it possible to determine the dominant hand used. The frequency of these oblique striations in an array of fossil hominins documents the typically modern pattern of 9 right- to 1 left-hander. This ratio among living Homo sapiens differs from that among chimpanzees and bonobos and more distant primate relatives. Together, all studies of living people affirm that dominant right-handedness is a uniquely modern human trait. The same pattern extends deep into our past. Thus far, the majority of inferred right-handed fossils come from Europe, but a single maxilla from a Homo habilis, OH-65, shows a predominance of right oblique scratches, thus extending right-handedness into the early Pleistocene of Africa. Other studies show right-handedness in more recent African, Chinese, and Levantine fossils, but the sample compiled for non-European fossil specimens remains small. Fossil specimens from Sima del los Huesos and a variety of European Neandertal sites are predominately right-handed. We argue the 9:1 handedness ratio in Neandertals and the earlier inhabitants of Europe constitutes evidence for a modern pattern of handedness well before the appearance of modern Homo sapiens. © 2017 Wiley Periodicals, Inc.

  5. Impacts of Digital Imaging versus Drawing on Student Learning in Undergraduate Biodiversity Labs

    Science.gov (United States)

    Basey, John M.; Maines, Anastasia P.; Francis, Clinton D.; Melbourne, Brett

    2014-01-01

    We examined the effects of documenting observations with digital imaging versus hand drawing in inquiry-based college biodiversity labs. Plant biodiversity labs were divided into two treatments, digital imaging (N = 221) and hand drawing (N = 238). Graduate-student teaching assistants (N = 24) taught one class in each treatment. Assessments…

  6. Fundus autofluorescence imaging in dry AMD: 2014 Jules Gonin lecture of the Retina Research Foundation.

    Science.gov (United States)

    Holz, Frank G; Steinberg, Julia S; Göbel, Arno; Fleckenstein, Monika; Schmitz-Valckenberg, Steffen

    2015-01-01

    Fundus autofluorescence (FAF) imaging allows for topographic mapping of intrisnic fluorophores in the retinal pigment epithelial cell monolayer, as well as mapping of other fluorophores that may occur with disease in the outer retina and the sub-neurosensory space. FAF imaging provides information not obtainable with other imaging modalities. Near-infrared fundus autofluorescence images can also be obtained in vivo, and may be largely melanin-derived. FAF imaging has been shown to be useful in a wide spectrum of macular and retinal diseases. The scope of applications now includes identification of diseased RPE in macular/retinal diseases, elucidating pathophysiological mechanisms, identification of early disease stages, refined phenotyping, identification of prognostic markers for disease progression, monitoring disease progression in the context of both natural history and interventional therapeutic studies, and objective assessment of luteal pigment distribution and density as well as RPE melanin distribution. Here, we review the use of FAF imaging in various phenotypic manifestations of dry AMD.

  7. Hands of early primates.

    Science.gov (United States)

    Boyer, Doug M; Yapuncich, Gabriel S; Chester, Stephen G B; Bloch, Jonathan I; Godinot, Marc

    2013-12-01

    Questions surrounding the origin and early evolution of primates continue to be the subject of debate. Though anatomy of the skull and inferred dietary shifts are often the focus, detailed studies of postcrania and inferred locomotor capabilities can also provide crucial data that advance understanding of transitions in early primate evolution. In particular, the hand skeleton includes characteristics thought to reflect foraging, locomotion, and posture. Here we review what is known about the early evolution of primate hands from a comparative perspective that incorporates data from the fossil record. Additionally, we provide new comparative data and documentation of skeletal morphology for Paleogene plesiadapiforms, notharctines, cercamoniines, adapines, and omomyiforms. Finally, we discuss implications of these data for understanding locomotor transitions during the origin and early evolutionary history of primates. Known plesiadapiform species cannot be differentiated from extant primates based on either intrinsic hand proportions or hand-to-body size proportions. Nonetheless, the presence of claws and a different metacarpophalangeal [corrected] joint form in plesiadapiforms indicate different grasping mechanics. Notharctines and cercamoniines have intrinsic hand proportions with extremely elongated proximal phalanges and digit rays relative to metacarpals, resembling tarsiers and galagos. But their hand-to-body size proportions are typical of many extant primates (unlike those of tarsiers, and possibly Teilhardina, which have extremely large hands). Non-adapine adapiforms and omomyids exhibit additional carpal features suggesting more limited dorsiflexion, greater ulnar deviation, and a more habitually divergent pollex than observed plesiadapiforms. Together, features differentiating adapiforms and omomyiforms from plesiadapiforms indicate increased reliance on vertical prehensile-clinging and grasp-leaping, possibly in combination with predatory behaviors in

  8. Shaping the Digital Future in Education – Together

    OpenAIRE

    Dale Andre Martin

    2018-01-01

    The theme of ICL2017 conference of the International Society for Engineering Pedagogy held in September was “Teaching and Learning in the Digital World”. The topic is particularly relevant today as digitalization – together with globalization, urbanization, demographic changes and climate change – has become one of the megatrends shaping our world. Between 2000 and 2014 globalization almost doubled the volume of the world commerce. By 2050 70% of the world’s population is expected to live in ...

  9. The Anatomy of Digital Trade Infrastructures

    DEFF Research Database (Denmark)

    Rukanova, Boriana; Zinner Henriksen, Helle; Henningsson, Stefan

    2017-01-01

    In global supply chains information about transactions resides in fragmented pockets within business and government systems. The introduction of digital trade infrastructures (DTI) that transcend organizational and systems domains is driven by the prospect of reducing this information fragmentation......, thereby enabling improved security and efficiency in trade process. To understand the problem at hand and build cumulative knowledge about its resolution a way to conceptualize the different digital trade infrastructure initiatives is needed. This paper develops the Digital Trade Infrastructure Framework...

  10. Reliability of maximal isometric knee strength testing with modified hand-held dynamometry in patients awaiting total knee arthroplasty: useful in research and individual patient settings? A reliability study

    Directory of Open Access Journals (Sweden)

    Koblbauer Ian FH

    2011-10-01

    Full Text Available Abstract Background Patients undergoing total knee arthroplasty (TKA often experience strength deficits both pre- and post-operatively. As these deficits may have a direct impact on functional recovery, strength assessment should be performed in this patient population. For these assessments, reliable measurements should be used. This study aimed to determine the inter- and intrarater reliability of hand-held dynamometry (HHD in measuring isometric knee strength in patients awaiting TKA. Methods To determine interrater reliability, 32 patients (81.3% female were assessed by two examiners. Patients were assessed consecutively by both examiners on the same individual test dates. To determine intrarater reliability, a subgroup (n = 13 was again assessed by the examiners within four weeks of the initial testing procedure. Maximal isometric knee flexor and extensor strength were tested using a modified Citec hand-held dynamometer. Both the affected and unaffected knee were tested. Reliability was assessed using the Intraclass Correlation Coefficient (ICC. In addition, the Standard Error of Measurement (SEM and the Smallest Detectable Difference (SDD were used to determine reliability. Results In both the affected and unaffected knee, the inter- and intrarater reliability were good for knee flexors (ICC range 0.76-0.94 and excellent for knee extensors (ICC range 0.92-0.97. However, measurement error was high, displaying SDD ranges between 21.7% and 36.2% for interrater reliability and between 19.0% and 57.5% for intrarater reliability. Overall, measurement error was higher for the knee flexors than for the knee extensors. Conclusions Modified HHD appears to be a reliable strength measure, producing good to excellent ICC values for both inter- and intrarater reliability in a group of TKA patients. High SEM and SDD values, however, indicate high measurement error for individual measures. This study demonstrates that a modified HHD is appropriate to

  11. An ensemble deep learning based approach for red lesion detection in fundus images.

    Science.gov (United States)

    Orlando, José Ignacio; Prokofyeva, Elena; Del Fresno, Mariana; Blaschko, Matthew B

    2018-01-01

    Diabetic retinopathy (DR) is one of the leading causes of preventable blindness in the world. Its earliest sign are red lesions, a general term that groups both microaneurysms (MAs) and hemorrhages (HEs). In daily clinical practice, these lesions are manually detected by physicians using fundus photographs. However, this task is tedious and time consuming, and requires an intensive effort due to the small size of the lesions and their lack of contrast. Computer-assisted diagnosis of DR based on red lesion detection is being actively explored due to its improvement effects both in clinicians consistency and accuracy. Moreover, it provides comprehensive feedback that is easy to assess by the physicians. Several methods for detecting red lesions have been proposed in the literature, most of them based on characterizing lesion candidates using hand crafted features, and classifying them into true or false positive detections. Deep learning based approaches, by contrast, are scarce in this domain due to the high expense of annotating the lesions manually. In this paper we propose a novel method for red lesion detection based on combining both deep learned and domain knowledge. Features learned by a convolutional neural network (CNN) are augmented by incorporating hand crafted features. Such ensemble vector of descriptors is used afterwards to identify true lesion candidates using a Random Forest classifier. We empirically observed that combining both sources of information significantly improve results with respect to using each approach separately. Furthermore, our method reported the highest performance on a per-lesion basis on DIARETDB1 and e-ophtha, and for screening and need for referral on MESSIDOR compared to a second human expert. Results highlight the fact that integrating manually engineered approaches with deep learned features is relevant to improve results when the networks are trained from lesion-level annotated data. An open source implementation of our

  12. Fundus oculi pigmentation studies simulating the fs-LASIK process Fundus oculi pigmentation studies simulating the fs-LASIK process

    Science.gov (United States)

    Sander, M.; Minet, O.; Zabarylo, U.; Müller, M.; Tetz, M. R.

    2012-06-01

    The femtosecond-laser in situ keratomileusis (fs-LASIK) technique has successfully entered the refractive surgery market to correct ametropia by cutting transparent corneal tissue with ultra-short laser pulses based on photodisruption. The laser pulses in the near infrared range (NIR) generate a laser-induced breakdown (LIOB) in the cornea. By propagating through the eye, a certain amount of the pulse is deposited in the cornea and the remaining energy interacts with the strong absorbing tissue behind. Due to the absorption by the retinal pigment epithelium and the transfer of the thermal energy to surrounding tissue, the transmitted energy can induce damage to the retina. The aim of this project was to find out the threshold influences concerning the tissue and the correlation between the results of the macroscopical appraisal and the fundus oculi pigmentation by simulating the fs-LASIK procedure with two various laser systems in the continuous wave (CW) and fs-regime. Therefore ex-vivo determinations were carried out macroscopically and histopathologically on porcine tissue.

  13. Digital supply chain management by using it systems

    OpenAIRE

    Stanišauskas, Ramūnas

    2018-01-01

    There are a lot of researches done to better understand the main principles of supply chain management, therefore supply chain management is well understood and quite common. On the other hand, nowadays more and more products and services are developed in digital environment, therefore regular supply chains are no longer viable and it is quite hard to adapt them. Suppliers in digital supply chain are creating digital products by using computer technologies and therefore digital products never...

  14. Human computer interaction using hand gestures

    CERN Document Server

    Premaratne, Prashan

    2014-01-01

    Human computer interaction (HCI) plays a vital role in bridging the 'Digital Divide', bringing people closer to consumer electronics control in the 'lounge'. Keyboards and mouse or remotes do alienate old and new generations alike from control interfaces. Hand Gesture Recognition systems bring hope of connecting people with machines in a natural way. This will lead to consumers being able to use their hands naturally to communicate with any electronic equipment in their 'lounge.' This monograph will include the state of the art hand gesture recognition approaches and how they evolved from their inception. The author would also detail his research in this area for the past 8 years and how the future might turn out to be using HCI. This monograph will serve as a valuable guide for researchers (who would endeavour into) in the world of HCI.

  15. Characteristics of Fundus Autofluorescence in Active Polypoidal Choroidal Vasculopathy

    Directory of Open Access Journals (Sweden)

    Zafer Öztaş

    2016-08-01

    Full Text Available Objectives: To define characteristic fundus autofluorescence (FAF findings in eyes with active polypoidal choroidal vasculopathy (PCV. Materials and Methods: Thirty-five eyes of 29 patients with active PCV who were diagnosed at Ege University Faculty of Medicine, Department of Ophthalmology, Retina Division between January 2012 and November 2014 were included in the study. All the patients underwent a complete ophthalmological examination including fundus photography, spectral-domain optical coherence tomography, fluorescein angiography, FAF photography, and indocyanine green angiography (ICGA. ICGA was used to diagnose active PCV and identify lesion components. FAF findings were described at the retinal site of the corresponding lesions identified and diagnosed using ICGA. Results: The mean age of the 29 study patients (15 men, 14 women was 64.6±7.5 years (range, 54-82 years. ICGA revealed active PCV in 35 eyes, consisting of polypoid lesions in 11 eyes (31.4%, branching vascular networks (BVN in 10 eyes (28.6%, and a combination of polypoid lesions and BVNs in 14 eyes (40%. On FAF images, 4 different patterns were detected at the corresponding retinal sites of 25 polypoid lesions detected by ICGA: confluent hypoautofluorescence with a hyperautofluorescent ring in 18 eyes (72%, hyperautofluorescence with hypoautofluorescent ring in 2 eyes (8%, confluent hypoautofluorescence in 1 eye (4%, and granular hypoautofluorescence in 1 eye (4%. The remaining 3 eyes (12% demonstrated blocked hypoautofluorescence because of the excessive hemorrhaging in the macula. The FAF images showed the granular hypoautofluorescent FAF pattern in all 24 BVNs (100% consistent with the location of the lesions on ICGA. Conclusion: The typical PCV lesions, polypoid lesions and BVNs had characteristic autofluorescent findings on FAF imaging. Non-invasive, quick, and repeatable FAF imaging can be considered a reliable and helpful diagnostic technique for the diagnosis of

  16. Digital Immigrants and Digital Natives: Learning Business Informatics at Higher Educational Level

    Directory of Open Access Journals (Sweden)

    Suša Dalia

    2014-09-01

    Full Text Available Background: The term digital natives refer to those born since the 1980s and have been growing up surrounded by technology. On the other hand, digital immigrants are born before 1980s and learned how to use technology later in life. Objectives: Goal of the paper is to explore attitudes of digital native students on the course of Business Informatics at higher educational institutions (HEIs, and to compare them with attitudes of digital immigrants. Methods/Approach: The survey was conducted in 2014 using the sample of first-year Business Informatics students from the Faculty of Economics and Business in Zagreb, Croatia. Results were compared with a research conducted in 1998. Results: In comparison to an earlier research, digital natives perceive their level of competency in the subject of Business Informatics before teaching practices much higher compared to digital immigrants. However, there is still an increase in digital native students’ level of competency in the subject before and after teaching practices. Conclusions: The research confirms a shift from digital immigrants to digital natives who show high level of interest for Business Informatics course topics and find its utility very high. However, constant improvement of delivering knowledge is needed in order to keep these high levels.

  17. Digital Data Matrix Scanner Developnent At Marshall Space Flight Center

    Science.gov (United States)

    2004-01-01

    Research at NASA's Marshall Space Flight Center has resulted in a system for reading hidden identification codes using a hand-held magnetic scanner. It's an invention that could help businesses improve inventory management, enhance safety, improve security, and aid in recall efforts if defects are discovered. Two-dimensional Data Matrix symbols consisting of letters and numbers permanently etched on items for identification and resembling a small checkerboard pattern are more efficient and reliable than traditional bar codes, and can store up to 100 times more information. A team led by Fred Schramm of the Marshall Center's Technology Transfer Department, in partnership with PRI,Torrance, California, has developed a hand-held device that can read this special type of coded symbols, even if covered by up to six layers of paint. Before this new technology was available, matrix symbols were read with optical scanners, and only if the codes were visible. This latest improvement in digital Data Matrix technologies offers greater flexibility for businesses and industries already using the marking system. Paint, inks, and pastes containing magnetic properties are applied in matrix symbol patterns to objects with two-dimensional codes, and the codes are read by a magnetic scanner, even after being covered with paint or other coatings. The ability to read hidden matrix symbols promises a wide range of benefits in a number of fields, including airlines, electronics, healthcare, and the automotive industry. Many industries would like to hide information on a part, so it can be read only by the party who put it there. For instance, the automotive industry uses direct parts marking for inventory control, but for aesthetic purposes the marks often need to be invisible. Symbols have been applied to a variety of materials, including metal, plastic, glass, paper, fabric and foam, on everything from electronic parts to pharmaceuticals to livestock. The portability of the hand-held

  18. A hard tissue cephalometric comparative study between hand tracing and computerized tracing

    Directory of Open Access Journals (Sweden)

    Ramachandra Prabhakar

    2014-01-01

    Full Text Available Aims: To analyze and compare the angular and linear hard tissue cephalometric measurements using hand-tracing and computerized tracings with Nemoceph and Dolphin software systems. Subjects and Methods: A total of 30 cephalograms were randomly chosen for study with the following criteria, cephalograms of patients with good contrast, no distortion, and minimal radiographic artifacts were considered using the digital method (Kodak 8000 C with 12 angular and nine linear parameters selected for the study. Comparisons were determined by post-hoc test using Tukey HSD method. The N-Par tests were performed using Kruskal-Walli′s method. Statistical Analysis Used: ANOVA and post-hoc. Results: The results of this study show that there is no significant difference in the angular and linear measurements recorded. The P values were significant at 0.05 levels for two parameters, Co-A and Co-Gn with the hand-tracing method. This was significant in ANOVA and post-hoc test by Tukey HSD method. Conclusions: This study of comparison provides support for transition from digital hand to computerized tracing methodology. In fact, digital computerized tracings were easier and less time consuming, with the same reliability irrespective of each method of tracing.

  19. Documents at hand: learning from paper to improve digital technologies

    NARCIS (Netherlands)

    Bondarenko, O.; Janssen, Ruud; Veer, van der G.C.; Gayle, C.

    2005-01-01

    In this paper the results of a two-year ethnographic study of the personal document management of 28 information workers is described. Both the paper and digital domain were taken into account during the study. The results reaffirmed that document management is strongly related to task management.

  20. Studies on hand-held visual communication device for the deaf and speech-impaired 2. Keyboard design.

    Science.gov (United States)

    Thurlow, W R

    1980-01-01

    Experiments with keyboard arrangements of letters show that simple alphabetic letter-key sequences with 4 to 5 letters in a row lead to most rapid visual search performance. Such arrangements can be used on keyboards operated by the index finger of one hand. Arrangement of letters in words offers a promising alternative because these arrangements can be readily memorized and can result in small interletter distances on the keyboard for frequently occurring letter sequences. Experiments on operation of keyboards show that a space or shift key operated by the left hand (which also holds the communication device) results in faster keyboard operation than when space or shift keys on the front of the keyboard (operated by right hand) are used. Special problems of the deaf-blind are discussed. Keyboard arrangements are investigated, and matching tactual codes are suggested.

  1. Fundus Image Features Extraction for Exudate Mining in Coordination with Content Based Image Retrieval: A Study

    Science.gov (United States)

    Gururaj, C.; Jayadevappa, D.; Tunga, Satish

    2018-06-01

    Medical field has seen a phenomenal improvement over the previous years. The invention of computers with appropriate increase in the processing and internet speed has changed the face of the medical technology. However there is still scope for improvement of the technologies in use today. One of the many such technologies of medical aid is the detection of afflictions of the eye. Although a repertoire of research has been accomplished in this field, most of them fail to address how to take the detection forward to a stage where it will be beneficial to the society at large. An automated system that can predict the current medical condition of a patient after taking the fundus image of his eye is yet to see the light of the day. Such a system is explored in this paper by summarizing a number of techniques for fundus image features extraction, predominantly hard exudate mining, coupled with Content Based Image Retrieval to develop an automation tool. The knowledge of the same would bring about worthy changes in the domain of exudates extraction of the eye. This is essential in cases where the patients may not have access to the best of technologies. This paper attempts at a comprehensive summary of the techniques for Content Based Image Retrieval (CBIR) or fundus features image extraction, and few choice methods of both, and an exploration which aims to find ways to combine these two attractive features, and combine them so that it is beneficial to all.

  2. Fully automatic algorithm for the analysis of vessels in the angiographic image of the eye fundus

    Directory of Open Access Journals (Sweden)

    Koprowski Robert

    2012-06-01

    Full Text Available Abstract Background The available scientific literature contains descriptions of manual, semi-automated and automated methods for analysing angiographic images. The presented algorithms segment vessels calculating their tortuosity or number in a given area. We describe a statistical analysis of the inclination of the vessels in the fundus as related to their distance from the center of the optic disc. Methods The paper presents an automated method for analysing vessels which are found in angiographic images of the eye using a Matlab implemented algorithm. It performs filtration and convolution operations with suggested masks. The result is an image containing information on the location of vessels and their inclination angle in relation to the center of the optic disc. This is a new approach to the analysis of vessels whose usefulness has been confirmed in the diagnosis of hypertension. Results The proposed algorithm analyzed and processed the images of the eye fundus using a classifier in the form of decision trees. It enabled the proper classification of healthy patients and those with hypertension. The result is a very good separation of healthy subjects from the hypertensive ones: sensitivity - 83%, specificity - 100%, accuracy - 96%. This confirms a practical usefulness of the proposed method. Conclusions This paper presents an algorithm for the automatic analysis of morphological parameters of the fundus vessels. Such an analysis is performed during fluorescein angiography of the eye. The presented algorithm automatically calculates the global statistical features connected with both tortuosity of vessels and their total area or their number.

  3. Fundus Image Features Extraction for Exudate Mining in Coordination with Content Based Image Retrieval: A Study

    Science.gov (United States)

    Gururaj, C.; Jayadevappa, D.; Tunga, Satish

    2018-02-01

    Medical field has seen a phenomenal improvement over the previous years. The invention of computers with appropriate increase in the processing and internet speed has changed the face of the medical technology. However there is still scope for improvement of the technologies in use today. One of the many such technologies of medical aid is the detection of afflictions of the eye. Although a repertoire of research has been accomplished in this field, most of them fail to address how to take the detection forward to a stage where it will be beneficial to the society at large. An automated system that can predict the current medical condition of a patient after taking the fundus image of his eye is yet to see the light of the day. Such a system is explored in this paper by summarizing a number of techniques for fundus image features extraction, predominantly hard exudate mining, coupled with Content Based Image Retrieval to develop an automation tool. The knowledge of the same would bring about worthy changes in the domain of exudates extraction of the eye. This is essential in cases where the patients may not have access to the best of technologies. This paper attempts at a comprehensive summary of the techniques for Content Based Image Retrieval (CBIR) or fundus features image extraction, and few choice methods of both, and an exploration which aims to find ways to combine these two attractive features, and combine them so that it is beneficial to all.

  4. Clinical research on intravitreal injection of bevacizumab in the treatment of macula lutea and retinal edema of ocular fundus disease.

    Science.gov (United States)

    Yan, Ying; Wang, Tao; Cao, Jing; Wang, Meng; Li, Fenghua

    2015-07-01

    This paper aimed to explore clinically curative effect of intravitreal injection of bevacizumab in the treatment of macula lutea and retinal edema of ocular fundus disease. The number of 300 patients (390 eyes) with ocular fundus diseases including retinal vein occlusion (RVO), diabetic retinopathy (DR), age-related macular degeneration (ARMD), central serous chorioretinopathy (CSC), choridal new vessel (CNV) received and cured in the hospital from February 2010 to February 2014 were given intravitreal injection of bevacizumab (1.5mg) with once per month and a total of 2-3 times. Results of patients' vision and fluorescence fundus angiography (FFA), optical coherence tomography (OCT) before and after treatment were compared and curative effects were evaluated. Vision of 349 eyes (89.49%) improved obviously with the average of more than 2 lines, patient's intraocular pressure (IOP) was normal and all indexes were clearly better; vision of 26 eyes (6.67%) was stable before the treatment and without any changes after the treatment, the situation of fundus got better without increased IOP; vision of 15 eyes (3.85%) decreased to some extent, and the symptoms eased slightly after symptomatic treatment. In the 1st day after intravitreal injection, best-corrected visual acuity increased to 0.239±0.175, best-corrected visual acuity in 1 m was 0.315±0.182, in 3m continuously climbed to 0.350±0.270, and in 6 m was 0.362±0.282. Compared with vision before injection, t value was t=3.184, t=7.213, t=9.274 and t=9.970 (P=0.002, P=0.000, P=0.000 and P=0.000) respectively, and all P were less than 0.01. Furthermore, the difference was significant if a=0.01, which could confirm that 1m best corrected visual acuity of patients after intravitreal injection improved clearly in combination with before injection and 3m and 6 m visions enhanced constantly after injection. To sum up, intravitreal injection of bevacizumab in treating ocular fundus disease improves patient's vision

  5. Shaping the Digital Future in Education – Together

    Directory of Open Access Journals (Sweden)

    Dale Andre Martin

    2018-05-01

    Full Text Available The theme of ICL2017 conference of the International Society for Engineering Pedagogy held in September was “Teaching and Learning in the Digital World”. The topic is particularly relevant today as digitalization – together with globalization, urbanization, demographic changes and climate change – has become one of the megatrends shaping our world. Between 2000 and 2014 globalization almost doubled the volume of the world commerce. By 2050 70% of the world’s population is expected to live in cities. Digitalization influences practically everything, global economy – from industry through healthcare – and also our society. The world has never been as connected as now.

  6. UTILIZATION OF FUNDUS AUTOFLUORESCENCE, SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY, AND ENHANCED DEPTH IMAGING IN THE CHARACTERIZATION OF BIETTI CRYSTALLINE DYSTROPHY IN DIFFERENT STAGES.

    Science.gov (United States)

    Li, Qian; Li, Yang; Zhang, Xiaohui; Xu, Zhangxing; Zhu, Xiaoqing; Ma, Kai; She, Haicheng; Peng, Xiaoyan

    2015-10-01

    To characterize Bietti crystalline dystrophy (BCD) in different stages using multiple imaging modalities. Sixteen participants clinically diagnosed as BCD were included in the retrospective study and were categorized into 3 stages according to fundus photography. Eleven patients were genetically confirmed. Fundus autofluorescence, spectral domain optical coherence tomography, and enhanced depth imaging features of BCD were analyzed. On fundus autofluorescence, the abnormal autofluorescence was shown to enlarge in area and decrease in intensity with stages. Using spectral domain optical coherence tomography, the abnormalities in Stage 1 were observed to localize in outer retinal layers, whereas in Stage 2 and Stage 3, more extensive retinal atrophy was seen. In enhanced depth imaging, the subfoveal choroidal layers were delineated clearly in Stage 1; in Stage 2, destructions were primarily found in the choriocapillaris with associated alterations in the outer vessels; Stage 3 BCD displayed severe choroidal thinning. Choroidal neovascularization and macular edema were exhibited with high incidence. IVS6-8del17bp/inGC of the CYP4V2 gene was the most common mutant allele. Noninvasive fundus autofluorescence, spectral domain optical coherence tomography, and enhanced depth imaging may help to characterize the chorioretinal pathology of BCD at different degrees, and therefore, we propose staging of BCD depending on those methods. Physicians should be cautious of the vision-threatening complications of the disease.

  7. Similar digit-based working memory in deaf signers and hearing non-signers despite digit span differences

    Directory of Open Access Journals (Sweden)

    Josefine eAndin

    2013-12-01

    Full Text Available Similar working memory (WM for lexical items has been demonstrated for signers and non-signers while short-term memory (STM is regularly poorer in deaf than hearing individuals. In the present study, we investigated digit-based WM and STM in Swedish and British deaf signers and hearing non-signers. To maintain good experimental control we used printed stimuli throughout and held response mode constant across groups. We showed that deaf signers have similar digit-based WM performance, despite shorter digit spans, compared to well-matched hearing non-signers. We found no difference between signers and non-signers on STM span for letters chosen to minimize phonological similarity or in the effects of recall direction. This set of findings indicates that similar WM for signers and non-signers can be generalized from lexical items to digits and suggests that poorer STM in deaf signers compared to hearing non-signers may be due to differences in phonological similarity across the language modalities of sign and speech.

  8. SEGMENTATION OF ENVIRONMENTAL TIME LAPSE IMAGE SEQUENCES FOR THE DETERMINATION OF SHORE LINES CAPTURED BY HAND-HELD SMARTPHONE CAMERAS

    Directory of Open Access Journals (Sweden)

    M. Kröhnert

    2017-09-01

    Full Text Available The relevance of globally environmental issues gains importance since the last years with still rising trends. Especially disastrous floods may cause in serious damage within very short times. Although conventional gauging stations provide reliable information about prevailing water levels, they are highly cost-intensive and thus just sparsely installed. Smartphones with inbuilt cameras, powerful processing units and low-cost positioning systems seem to be very suitable wide-spread measurement devices that could be used for geo-crowdsourcing purposes. Thus, we aim for the development of a versatile mobile water level measurement system to establish a densified hydrological network of water levels with high spatial and temporal resolution. This paper addresses a key issue of the entire system: the detection of running water shore lines in smartphone images. Flowing water never appears equally in close-range images even if the extrinsics remain unchanged. Its non-rigid behavior impedes the use of good practices for image segmentation as a prerequisite for water line detection. Consequently, we use a hand-held time lapse image sequence instead of a single image that provides the time component to determine a spatio-temporal texture image. Using a region growing concept, the texture is analyzed for immutable shore and dynamic water areas. Finally, the prevalent shore line is examined by the resultant shapes. For method validation, various study areas are observed from several distances covering urban and rural flowing waters with different characteristics. Future work provides a transformation of the water line into object space by image-to-geometry intersection.

  9. Segmentation of Environmental Time Lapse Image Sequences for the Determination of Shore Lines Captured by Hand-Held Smartphone Cameras

    Science.gov (United States)

    Kröhnert, M.; Meichsner, R.

    2017-09-01

    The relevance of globally environmental issues gains importance since the last years with still rising trends. Especially disastrous floods may cause in serious damage within very short times. Although conventional gauging stations provide reliable information about prevailing water levels, they are highly cost-intensive and thus just sparsely installed. Smartphones with inbuilt cameras, powerful processing units and low-cost positioning systems seem to be very suitable wide-spread measurement devices that could be used for geo-crowdsourcing purposes. Thus, we aim for the development of a versatile mobile water level measurement system to establish a densified hydrological network of water levels with high spatial and temporal resolution. This paper addresses a key issue of the entire system: the detection of running water shore lines in smartphone images. Flowing water never appears equally in close-range images even if the extrinsics remain unchanged. Its non-rigid behavior impedes the use of good practices for image segmentation as a prerequisite for water line detection. Consequently, we use a hand-held time lapse image sequence instead of a single image that provides the time component to determine a spatio-temporal texture image. Using a region growing concept, the texture is analyzed for immutable shore and dynamic water areas. Finally, the prevalent shore line is examined by the resultant shapes. For method validation, various study areas are observed from several distances covering urban and rural flowing waters with different characteristics. Future work provides a transformation of the water line into object space by image-to-geometry intersection.

  10. Breast-density assessment with hand-held ultrasound: A novel biomarker to assess breast cancer risk and to tailor screening?

    Science.gov (United States)

    Sanabria, Sergio J; Goksel, Orcun; Martini, Katharina; Forte, Serafino; Frauenfelder, Thomas; Kubik-Huch, Rahel A; Rominger, Marga B

    2018-03-19

    To assess feasibility and diagnostic accuracy of a novel hand-held ultrasound (US) method for breast density assessment that measures the speed of sound (SoS), in comparison to the ACR mammographic (MG) categories. ACR-MG density (a=fatty to d=extremely dense) and SoS-US were assessed in the retromamillary, inner and outer segments of 106 women by two radiographers. A conventional US system was used for SoS-US. A reflector served as timing reference for US signals transmitted through the breasts. Four blinded readers assessed average SoS (m/s), ΔSoS (segment-variation SoS; m/s) and the ACR-MG density. The highest SoS and ΔSoS values of the three segments were used for MG-ACR whole breast comparison. SoS-US breasts were examined in densities a-d were 1,421 m/s (SD 14), 1,432 m/s (SD 17), 1,448 m/s (SD 20) and 1,500 m/s (SD 31), with significant differences between all groups (pdensity was evident (r s =0.622, p=density without discomfort, readers evaluated measurements with high inter-reader agreement, and SoS-US correlated significantly with ACR-MG breast-density categories. • The novel speed-of-sound ultrasound correlated significantly with mammographic ACR breast density categories. • Radiographers measured breast density without women discomfort or radiation. • SoS-US can be implemented on a standard US machine. • SoS-US shows potential for a quantifiable, cost-effective assessment of breast density.

  11. Development of a digital reactivity meter and reactor physics data processor

    International Nuclear Information System (INIS)

    Shimazu, Y.; Nakano, Y.; Tahara, Y.; Okayama, T.

    1986-01-01

    Reactor physics tests at initial startup and after refueling are performed to verify the nuclear design and to assure safe operations thereafter. Analogue computers and instruments have been widely used for the acquisition of data and those data have been reduced by hand. These conventional procedures, however, require much time and labor. On the other hand, the development of digital computers and devices has made great progress. Under these circumstances the authors have digitalized the procedures mentioned. As described in the paper, the digitalized reactivity meter and data processor system proved to function satisfactorily as intended at the design stage

  12. TEST-RETEST RELIABILITY OF HAND GRIP STRENGTH MEASUREMENT USING A JAMAR HAND DYNAMOMETER IN PATIENTS WITH ACUTE AND CHRONIC CERVICAL RADICULOPATHY

    Directory of Open Access Journals (Sweden)

    Ejazi G

    2017-12-01

    Full Text Available Background: To evaluate the test-retest reliability of Jamar hand held dynamometer for measuring handgrip strength (HGS in patients with acute and chronic cervical radiculopathy and to find out the difference in measurement of the handgrip strength between acute and chronic cervical radiculopathy. Methods: A prospective, observational and non-experimental, the comparative study design was used. A sample of 72 subjects (37 women and 35 men suffering from cervical radiculopathy were divided into two groups i.e., Group A(acute and Group B(chronic, handgrip strength was measured using Jamar hand held dynamometer on two occasions by the same rater with an interval of 7-days. Data collection was based on standard guidelines of American Society of Hand Therapists. Three gripping trials (measured in Kg with patient’s arm in standardized arm position were recorded. The data was analyzed from the mean score obtained from the sample. Result: One-way Analysis of Variance(ANOVA was used to evaluate test-retest reliability and Tukey-Kramer Multiple Comparison Test used to find the difference between handgrip strength among acute and chronic Cervical radiculopathy cases. Greater P-value (>0.05 in both testing session, as well as 95% of the confidence interval, shows the reliability of the instrument and lesser p-value (0.05 in female subjects shows no significant difference in handgrip strength between the two groups. Conclusion: Excellent test-retest reliability for hand grip strength measurement was measured in patients with acute and chronic cervical radiculopathy shows that the equipment could be used as an assessment tool for this patient and significant difference exists among male handgrip strength between acute and chronic cervical radiculopathy cases whereas no difference exists among female handgrip strength between acute and chronic cervical radiculopathy cases.

  13. Effects of non-surgical factors on digital replantation survival rate: a meta-analysis.

    Science.gov (United States)

    Ma, Z; Guo, F; Qi, J; Xiang, W; Zhang, J

    2016-02-01

    This study aimed to evaluate the risk factors affecting survival rate of digital replantation by a meta-analysis. A computer retrieval of MEDLINE, OVID, EMBASE, and CNKI databases was conducted to identify citations for digital replantation with digit or finger or thumb or digital or fingertip and replantation as keywords. RevMan 5.2 software was used to calculate the pooled odds ratios. In total, there were 4678 amputated digits in 2641 patients. Gender and ischemia time had no significant influence on the survival rate of amputation replantation (P > 0.05). Age, injured hand, injury type, zone, and the method of preservation the amputated digit significantly influence the survival rate of digital replantation (P < 0.05). Children, right hand, crush, or avulsion and little finger are the risk factors that adversely affect the outcome. Level 5*. © The Author(s) 2015.

  14. The Plastic Surgery Hand Curriculum.

    Science.gov (United States)

    Silvestre, Jason; Levin, L Scott; Serletti, Joseph M; Chang, Benjamin

    2015-12-01

    Designing an effective hand rotation for plastic surgery residents is difficult. The authors address this limitation by elucidating the critical components of the hand curriculum during plastic surgery residency. Hand questions on the Plastic Surgery In-Service Training Exam for six consecutive years (2008 to 2013) were characterized by presence of imaging, vignette setting, question taxonomy, answer domain, anatomy, and topic. Answer references were quantified by source and year of publication. Two hundred sixty-six questions were related to hand surgery (22.7 percent of all questions; 44.3 per year) and 61 were accompanied by an image (22.9 percent). Vignettes tended to be clinic- (50.0 percent) and emergency room-based (35.3 percent) (p < 0.001). Questions required decision-making (60.5 percent) over interpretation (25.9 percent) and recall skills (13.5 percent) (p < 0.001). Answers focused on interventions (57.5 percent) over anatomy/pathology (25.2 percent) and diagnoses (17.3 percent) (p < 0.001). Nearly half of the questions focused on the digits. The highest yield topics were trauma (35.3 percent), reconstruction (24.4 percent), and aesthetic and functional problems (14.2 percent). The Journal of Hand Surgery (American volume) (20.5 percent) and Plastic and Reconstructive Surgery (18.0 percent) were the most-cited journals, and the median publication lag was 7 years. Green's Operative Hand Surgery was the most-referenced textbook (41.8 percent). These results will enable trainees to study hand surgery topics with greater efficiency. Faculty can use these results to ensure that tested topics are covered during residency training. Thus, a benchmark is established to improve didactic, clinical, and operative experiences in hand surgery.

  15. Automatic non-proliferative diabetic retinopathy screening system based on color fundus image.

    Science.gov (United States)

    Xiao, Zhitao; Zhang, Xinpeng; Geng, Lei; Zhang, Fang; Wu, Jun; Tong, Jun; Ogunbona, Philip O; Shan, Chunyan

    2017-10-26

    Non-proliferative diabetic retinopathy is the early stage of diabetic retinopathy. Automatic detection of non-proliferative diabetic retinopathy is significant for clinical diagnosis, early screening and course progression of patients. This paper introduces the design and implementation of an automatic system for screening non-proliferative diabetic retinopathy based on color fundus images. Firstly, the fundus structures, including blood vessels, optic disc and macula, are extracted and located, respectively. In particular, a new optic disc localization method using parabolic fitting is proposed based on the physiological structure characteristics of optic disc and blood vessels. Then, early lesions, such as microaneurysms, hemorrhages and hard exudates, are detected based on their respective characteristics. An equivalent optical model simulating human eyes is designed based on the anatomical structure of retina. Main structures and early lesions are reconstructed in the 3D space for better visualization. Finally, the severity of each image is evaluated based on the international criteria of diabetic retinopathy. The system has been tested on public databases and images from hospitals. Experimental results demonstrate that the proposed system achieves high accuracy for main structures and early lesions detection. The results of severity classification for non-proliferative diabetic retinopathy are also accurate and suitable. Our system can assist ophthalmologists for clinical diagnosis, automatic screening and course progression of patients.

  16. Clinical aspects of the hand-arm vibration syndrome. A review.

    Science.gov (United States)

    Pyykkö, I

    1986-10-01

    At present it seems likely that the different components of the hand-arm vibration syndrome, eg, vibration-induced white finger (VWF), numbing of the hands and arms, muscular fatigue, and occasionally prevalent bone degeneration, may arise independently, and therefore they should be evaluated separately. Evidence of changes caused in the autonomic nervous functions of the body by local vibration is not conclusive. The vascular history should be confirmed objectively with a cold provocation test under laboratory conditions. In individual diagnostics it is useful to record (with modern plethysmographic techniques) the recovery of digital temperature, digital blood pressure, and flow after local cooling. Vibrotactile perception measurement seems to be suitable for group diagnosis. Much of the diagnostic weight for VWF can be obtained from accurate case histories, although, for early changes, the history may be atypical. The lack of simple objective tests for evaluating the hand-arm vibration syndrome makes it difficult to, eg, confirm the history of its different components objectively and estimate the extent of the disability it causes.

  17. Crowdsourcing to Evaluate Fundus Photographs for the Presence of Glaucoma.

    Science.gov (United States)

    Wang, Xueyang; Mudie, Lucy I; Baskaran, Mani; Cheng, Ching-Yu; Alward, Wallace L; Friedman, David S; Brady, Christopher J

    2017-06-01

    To assess the accuracy of crowdsourcing for grading optic nerve images for glaucoma using Amazon Mechanical Turk before and after training modules. Images (n=60) from 2 large population studies were graded for glaucoma status and vertical cup-to-disc ratio (VCDR). In the baseline trial, users on Amazon Mechanical Turk (Turkers) graded fundus photos for glaucoma and VCDR after reviewing annotated example images. In 2 additional trials, Turkers viewed a 26-slide PowerPoint training or a 10-minute video training and passed a quiz before being permitted to grade the same 60 images. Each image was graded by 10 unique Turkers in all trials. The mode of Turker grades for each image was compared with an adjudicated expert grade to determine accuracy as well as the sensitivity and specificity of Turker grading. In the baseline study, 50% of the images were graded correctly for glaucoma status and the area under the receiver operating characteristic (AUROC) was 0.75 [95% confidence interval (CI), 0.64-0.87]. Post-PowerPoint training, 66.7% of the images were graded correctly with AUROC of 0.86 (95% CI, 0.78-0.95). Finally, Turker grading accuracy was 63.3% with AUROC of 0.89 (95% CI, 0.83-0.96) after video training. Overall, Turker VCDR grades for each image correlated with expert VCDR grades (Bland-Altman plot mean difference=-0.02). Turkers graded 60 fundus images quickly and at low cost, with grading accuracy, sensitivity, and specificity, all improving with brief training. With effective education, crowdsourcing may be an efficient tool to aid in the identification of glaucomatous changes in retinal images.

  18. Health Effects of Digital Textbooks on School-Age Children: A Grounded Theory Approach

    OpenAIRE

    Seomun, GA; Lee, JA; Kim, EY; Im, MY; Kim, M; Park, SA; Lee, Y

    2013-01-01

    This qualitative study used the grounded theory approach to analyze digital textbook-related health experiences of school-age children. In-depth interviews were held with 40 elementary school students who had used digital textbooks for at least a year. Data analysis revealed a total of 56 concepts, 20 subcategories, and 11 categories related to digital textbook health issues, the central phenomena being "health-related experiences." Students' health-related experiences were classified into "p...

  19. Pengaruh Senam Nifas terhadap Penurunan Tinggi Fundus Uteri pada Ibu Post Partum di RSUP DR. M. Djamil Padang

    Directory of Open Access Journals (Sweden)

    Nurniati Tianastia Rullynil

    2014-09-01

    Full Text Available AbstrakPerdarahan merupakan penyebab utama kesakitan dan kematian ibu pada masa nifas, dimana 50%-60% karena kegagalan miometrium berkontraksi secara sempurna. Salah satu asuhan untuk memaksimalkan kontraksi uterus pada masa nifas adalah dengan melaksanakan senam nifas, guna mempercepat proses involusi uteri. Tujuan penelitian ini adalah untuk mengetahui pengaruh senam nifas terhadap penurunan tinggi fundus uteri (TFU pada ibu post partum. Penelitian ini merupakan studi eksperimental dengan Post Test Only Control Group Design. Alat yang digunakan dalam penelitian berupa kaliper pelvimetri. Diberikan perlakuan senam nifas pada kelompok intervensi dan tidak senam nifas pada kelompok kontrol, kemudian dilakukan pengukuran tinggi fundus uteri hari ke-1, hari ke-3 dan hari ke-6. Data dianalisa menggunakan Uji General Linier Model (GLM. Rerata TFU hari ke-1 pada kelompok intervensi 12,37±0,72 dan 12,42±0,54 pada kelompok kontrol. Rerata TFU hari ke-3 pada kelompok intervensi 9,00±0,94 dan 9,87±0,75 pada kelompok kontrol. Sedangkan rerata TFU hari ke-6 pada kelompok intervensi 5,72±0,88 dan 7,37±0,68 pada kelompok kontrol. Terdapat perbedaan yang signifikan penurunan tinggi fundus uteri antara kedua kelompok pada hari ke-3 (p=0,00 dan hari ke 6 (p=0,00. Dari hasil penelitian dapat disimpulkan bahwa senam nifas berpengaruh terhadap penurunan tinggi fundus uteri. Penurunan tinggi fundus uteri pada kelompok intervensi lebih turun dibanding kelompok kontrol.Kata kunci: senam nifas, tinggi fundus uteri, post partumAbstractHemorrhage is a major cause of maternal morbidity and mortality in the puerperium, about 50%-60% of hemorrhage occurs due to failure of myometrium to contract completely. One care to maximaze uterine contraction during the puerperium is by implementing parturition gymnastics in order to accelarate the process of uterine involution. The purpose of this study was to determine the effect of parturition gymnastics on a decreasing of

  20. Differentiation of ocular fundus fluorophores by fluorescence lifetime imaging using multiple excitation and emission wavelengths

    Science.gov (United States)

    Hammer, M.; Schweitzer, D.; Schenke, S.; Becker, W.; Bergmann, A.

    2006-10-01

    Ocular fundus autofluorescence imaging has been introduced into clinical diagnostics recently. It is in use for the observation of the age pigment lipofuscin, a precursor of age - related macular degeneration (AMD). But other fluorophores may be of interest too: The redox pair FAD - FADH II provides information on the retinal energy metabolism, advanced glycation end products (AGE) indicate protein glycation associated with pathologic processes in diabetes as well as AMD, and alterations in the fluorescence of collagen and elastin in connective tissue give us the opportunity to observe fibrosis by fluorescence imaging. This, however, needs techniques able to differentiate particular fluorophores despite limited permissible ocular exposure as well as excitation wavelength (limited by the transmission of the human ocular lens to >400 nm). We present an ophthalmic laser scanning system (SLO), equipped with picosecond laser diodes (FWHM 100 ps, 446 nm or 468 nm respectively) and time correlated single photon counting (TCSPC) in two emission bands (500 - 560 nm and 560 - 700 nm). The decays were fitted by a bi-exponential model. Fluorescence spectra were measured by a fluorescence spectrometer fluorolog. Upon excitation at 446 nm, the fluorescence of AGE, FAD, and lipofuscin were found to peak at 503 nm, 525 nm, and 600 nm respectively. Accordingly, the statistical distribution of the fluorescence decay times was found to depend on the different excitation wavelengths and emission bands used. The use of multiple excitation and emission wavelengths in conjunction with fluorescence lifetime imaging allows us to discriminate between intrinsic fluorophores of the ocular fundus. Taken together with our knowledge on the anatomical structure of the fundus, these findings suggest an association of the short, middle and long fluorescence decay time to the retinal pigment epithelium, the retina, and connective tissue respectively.

  1. ULTRA-WIDE-FIELD FUNDUS AUTOFLUORESCENCE FINDINGS IN PATIENTS WITH ACUTE ZONAL OCCULT OUTER RETINOPATHY.

    Science.gov (United States)

    Shifera, Amde Selassie; Pennesi, Mark E; Yang, Paul; Lin, Phoebe

    2017-06-01

    To determine whether ultra-wide-field fundus autofluorescence (UWFFAF) findings in acute zonal occult outer retinopathy correlated well with perimetry, optical coherence tomography, and electroretinography findings. Retrospective observational study on 16 eyes of 10 subjects with AZOOR seen at a single referral center from October 2012 to March 2015 who had UWFFAF performed. Chi-square analysis was performed to compare categorical variables, and Mann-Whitney U test used for comparisons of nonparametric continuous variables. All eyes examined within 3 months of symptom onset (five of the five eyes) had diffusely hyperautofluorescent areas on UWFFAF. The remaining eyes contained hypoautofluorescent lesions with hyperautofluorescent borders. In 11/16 (68.8%) eyes, UWFFAF showed the full extent of lesions that would not have been possible with standard fundus autofluorescence centered on the fovea. There were 3 patterns of spread: centrifugal spread (7/16, 43.8%), centripetal spread (5/16, 31.3%), and centrifugal + centripetal spread (4/16, 25.0%). The UWFFAF lesions corresponded well with perimetric, optical coherence tomography, and electroretinography abnormalities. The UWFFAF along with optical coherence tomography can be useful in the evaluation and monitoring of acute zonal occult outer retinopathy patients.

  2. Fundus autofluorescence and optical coherence tomography in the management of progressive outer retinal necrosis

    Science.gov (United States)

    Yeh, Steven; Wong, Wai T.; Weichel, Eric D.; Lew, Julie C.; Chew, Emily Y.; Nussenblatt, Robert B.

    2011-01-01

    A 41 year-old female patient with acquired immune deficiency syndrome (AIDS) presented with progressive nasal visual field loss in her right eye. Ophthalmic exam revealed widespread areas of retinal opacification with hemorrhage consistent with progressive outer retinal necrosis (PORN), which was confirmed by polymerase chain reaction (PCR) for varicella zoster virus (VZV) DNA. The patient was treated with intravenous and intravitreal foscarnet and ganciclovir with a resultant improvement clinically. Optical coherence tomography (OCT) and fundus autofluorescence (FAF) imaging revealed progressive changes indicative of widespread retinal pigment epithelial (RPE) and outer retinal dysfunction. OCT was useful in documenting progressive changes in macular architecture during therapy including neurosensory elevation, cystoid macular edema, and severe outer retinal necrosis, at initial exam, 1 week, and 1 month follow-up. Fundus autofluorescence revealed areas of stippled, hyperfluorescence within extensive zones of hypofluorescence, which progressed during the follow-up period. These areas appeared to represent lipofuscin or its photoreactive components within larger regions of RPE loss. The combination of OCT and FAF was useful in the characterization of the RPE and retinal anatomy in this patient with PORN. PMID:20337261

  3. Large-scale digitizer system, analog converters

    International Nuclear Information System (INIS)

    Althaus, R.F.; Lee, K.L.; Kirsten, F.A.; Wagner, L.J.

    1976-10-01

    Analog to digital converter circuits that are based on the sharing of common resources, including those which are critical to the linearity and stability of the individual channels, are described. Simplicity of circuit composition is valued over other more costly approaches. These are intended to be applied in a large-scale processing and digitizing system for use with high-energy physics detectors such as drift-chambers or phototube-scintillator arrays. Signal distribution techniques are of paramount importance in maintaining adequate signal-to-noise ratio. Noise in both amplitude and time-jitter senses is held sufficiently low so that conversions with 10-bit charge resolution and 12-bit time resolution are achieved

  4. Centrifugal Expansion of Fundus Autofluorescence Patterns in Stargardt Disease Over Time

    Science.gov (United States)

    Cukras, Catherine A.; Wong, Wai T.; Caruso, Rafael; Cunningham, Denise; Zein, Wadih; Sieving, Paul

    2012-01-01

    Objective Changing lipofuscin and melanin content in RPE cells has been hypothesized to contribute to Stargardt disease pathogenesis. Longitudinal study of autofluorescence in Stargardt disease which reflect changing fluorophore compositions can reveal aspects of disease progression not previously evident. Method We examined the temporal-spatial patterns of fundus autofluorescence with excitation at both 488 nm (standard fundus autofluorescence, FAF) and 795nm (near infrared autofluorescence, NIA) in a longitudinal case series involving 8 eyes of 4 patients (range of follow-up = 11 to 57 months; mean = 39 months). Image processing was performed to analyze spatial and temporal cross-modality associations. Results Longitudinal FAF imaging of fleck lesions revealed hyperautofluorescent lesions that extended in a centrifugal direction from the fovea with time. Patterns of spread were non-random and followed a radial path that leaves behind a trail of diminishing autofluorescence. Longitudinal NIA imaging also demonstrated centrifugal lesion spread, but with fewer hyperautofluorescent lesions, suggestive of more transient hyperautofluorescence and more rapid decay at longer wavelengths. FAF and NIA abnormalities were spatially correlated to each other, and together reflect systematic progressions in fleck distribution and fluorophore composition occurring during the natural history of the disease. Conclusion Stargardt disease fleck lesions do not evolve randomly in location but instead follow consistent patterns of radial expansion and a systematic decay of autofluorescence that reflect changing lipofuscin and melanin compositions in RPE cells. These progressive foveal-to-peripheral changes are helpful in elucidating molecular and cellular mechanisms underlying Stargardt disease and may constitute potential outcome measures in clinical trials. PMID:21987580

  5. Automatic classification of pathological myopia in retinal fundus images using PAMELA

    Science.gov (United States)

    Liu, Jiang; Wong, Damon W. K.; Tan, Ngan Meng; Zhang, Zhuo; Lu, Shijian; Lim, Joo Hwee; Li, Huiqi; Saw, Seang Mei; Tong, Louis; Wong, Tien Yin

    2010-03-01

    Pathological myopia is the seventh leading cause of blindness. We introduce a framework based on PAMELA (PAthological Myopia dEtection through peripapilLary Atrophy) for the detection of pathological myopia from fundus images. The framework consists of a pre-processing stage which extracts a region of interest centered on the optic disc. Subsequently, three analysis modules focus on detecting specific visual indicators. The optic disc tilt ratio module gives a measure of the axial elongation of the eye through inference from the deformation of the optic disc. In the texturebased ROI assessment module, contextual knowledge is used to demarcate the ROI into four distinct, clinically-relevant zones in which information from an entropy transform of the ROI is analyzed and metrics generated. In particular, the preferential appearance of peripapillary atrophy (PPA) in the temporal zone compared to the nasal zone is utilized by calculating ratios of the metrics. The PPA detection module obtains an outer boundary through a level-set method, and subtracts this region against the optic disc boundary. Temporal and nasal zones are obtained from the remnants to generate associated hue and color values. The outputs of the three modules are used as in a SVM model to determine the presence of pathological myopia in a retinal fundus image. Using images from the Singapore Eye Research Institute, the proposed framework reported an optimized accuracy of 90% and a sensitivity and specificity of 0.85 and 0.95 respectively, indicating promise for the use of the proposed system as a screening tool for pathological myopia.

  6. The significance of fluorescein angiography in the early diagnosis of lesions on ocular fundus at pseudoxanthoma elasticum patients.

    Science.gov (United States)

    Bogdanowski, T; Gluza, J; Rasiewicz, D

    1977-05-27

    The role of fluorescein angiography in early diagnosis of lesions on fundus of the eye at pseudoxanthoma elasticum patients has been shown. The authors show angiographic changes on the basis of three cases of pseudoxanthoma elasticum patients.

  7. Color Fundus Photography, Optical Coherence Tomography, and Fluorescein Angiography in Diagnosing Polypoidal Choroidal Vasculopathy.

    Science.gov (United States)

    Chaikitmongkol, Voraporn; Khunsongkiet, Preeyanuch; Patikulsila, Direk; Ratanasukon, Mansing; Watanachai, Nawat; Jumroendararasame, Chaisiri; Mayerle, Catherine B; Han, Ian C; Chen, Connie J; Winaikosol, Pawara; Dejkriengkraikul, Chutikarn; Choovuthayakorn, Janejit; Kunavisarut, Paradee; Bressler, Neil M

    2018-05-10

    To determine sensitivity and specificity of polypoidal choroidal vasculopathy (PCV) diagnosis using color fundus photography (CFP), optical coherence tomography (OCT) and fundus fluorescein angiography (FFA) without indocyanine-green angiography (ICGA). Validity analysis. Treatment-naïve eyes with serous/serosanguinous maculopathy undergoing CFP, OCT, FFA and ICGA imaging before treatment at a university-hospital in Thailand (January 2013 to June 2015) were identified. Images of each subject were categorized into 4 sets (set A: CFP; set B: CFP+OCT; set C: CFP+FFA; set D: CFP+OCT+FFA). Six graders, 3 from Thailand (PCV endemic area) and 3 from U.S. (non-endemic area), individually reviewed each set (without ICG), and determined if the presumed diagnosis was PCV. In parallel, 2 other graders confirmed if each case had PCV or not using EVEREST criteria (including ICGA). Sensitivity and specificity of a PCV diagnosis with each set (without ICGA) were analyzed compared with diagnoses including ICGA. Of 119 study eyes (113 subjects, 57% male, mean age±SD 59.9±13.8), definite PCV diagnosis was 40.3%. Sensitivity of sets A, B, C, D: 0.63 (95%CI: 0.47-0.76), 0.83 (95%CI: 0.69-0.92), 0.54 (95%CI: 0.39-0.68), 0.67 (95%CI: 0.51-0.79). Specificity were 0.93 (95% CI: 0.84-0.97), 0.83 (95%CI: 0.72-0.91), 0.97 (95%CI: 0.89-0.99), 0.92 (95%CI: 0.82-0.97). Accuracies: 0.81 (95%CI: 0.73-0.88), 0.83 (95%CI: 0.76-0.90), 0.79 (95%CI: 0.73-0.87), 0.82 (95%CI: 0.74-0.88). Discrepancies between Thai and US graders existed through sets A, C, and D. These data suggest without ICGA, fundus photography combined with OCT provides high sensitivity and high specificity to diagnosis PCV; adding FFA does not improve accuracy. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Nerve canals at the fundus of the internal auditory canal on high-resolution temporal bone CT

    International Nuclear Information System (INIS)

    Ji, Yoon Ha; Youn, Eun Kyung; Kim, Seung Chul

    2001-01-01

    To identify and evaluate the normal anatomy of nerve canals in the fundus of the internal auditory canal which can be visualized on high-resolution temporal bone CT. We retrospectively reviewed high-resolution (1 mm thickness and interval contiguous scan) temporal bone CT images of 253 ears in 150 patients who had not suffered trauma or undergone surgery. Those with a history of uncomplicated inflammatory disease were included, but those with symptoms of vertigo, sensorineural hearing loss, or facial nerve palsy were excluded. Three radiologists determined the detectability and location of canals for the labyrinthine segment of the facial, superior vestibular and cochlear nerve, and the saccular branch and posterior ampullary nerve of the inferior vestibular nerve. Five bony canals in the fundus of the internal auditory canal were identified as nerve canals. Four canals were identified on axial CT images in 100% of cases; the so-called singular canal was identified in only 68%. On coronal CT images, canals for the labyrinthine segment of the facial and superior vestibular nerve were seen in 100% of cases, but those for the cochlear nerve, the saccular branch of the inferior vestibular nerve, and the singular canal were seen in 90.1%, 87.4% and 78% of cases, respectiveIy. In all detectable cases, the canal for the labyrinthine segment of the facial nerve was revealed as one which traversed anterolateralIy, from the anterosuperior portion of the fundus of the internal auditory canal. The canal for the cochlear nerve was located just below that for the labyrinthine segment of the facial nerve, while that canal for the superior vestibular nerve was seen at the posterior aspect of these two canals. The canal for the saccular branch of the inferior vestibular nerve was located just below the canal for the superior vestibular nerve, and that for the posterior ampullary nerve, the so-called singular canal, ran laterally or posteolateralIy from the posteroinferior aspect of

  9. Nerve canals at the fundus of the internal auditory canal on high-resolution temporal bone CT

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Yoon Ha; Youn, Eun Kyung; Kim, Seung Chul [Sungkyunkwan Univ., School of Medicine, Seoul (Korea, Republic of)

    2001-12-01

    To identify and evaluate the normal anatomy of nerve canals in the fundus of the internal auditory canal which can be visualized on high-resolution temporal bone CT. We retrospectively reviewed high-resolution (1 mm thickness and interval contiguous scan) temporal bone CT images of 253 ears in 150 patients who had not suffered trauma or undergone surgery. Those with a history of uncomplicated inflammatory disease were included, but those with symptoms of vertigo, sensorineural hearing loss, or facial nerve palsy were excluded. Three radiologists determined the detectability and location of canals for the labyrinthine segment of the facial, superior vestibular and cochlear nerve, and the saccular branch and posterior ampullary nerve of the inferior vestibular nerve. Five bony canals in the fundus of the internal auditory canal were identified as nerve canals. Four canals were identified on axial CT images in 100% of cases; the so-called singular canal was identified in only 68%. On coronal CT images, canals for the labyrinthine segment of the facial and superior vestibular nerve were seen in 100% of cases, but those for the cochlear nerve, the saccular branch of the inferior vestibular nerve, and the singular canal were seen in 90.1%, 87.4% and 78% of cases, respectiveIy. In all detectable cases, the canal for the labyrinthine segment of the facial nerve was revealed as one which traversed anterolateralIy, from the anterosuperior portion of the fundus of the internal auditory canal. The canal for the cochlear nerve was located just below that for the labyrinthine segment of the facial nerve, while that canal for the superior vestibular nerve was seen at the posterior aspect of these two canals. The canal for the saccular branch of the inferior vestibular nerve was located just below the canal for the superior vestibular nerve, and that for the posterior ampullary nerve, the so-called singular canal, ran laterally or posteolateralIy from the posteroinferior aspect of

  10. Our Digital Conversion

    Science.gov (United States)

    Edwards, Mark

    2012-01-01

    In this article, the author describes their digital conversion initiative at Mooresville Graded School District. The project has placed a MacBook Air laptop in the hands of every 3rd through 12th grader and their teachers in the district over the past four years, with over 5,000 computers distributed. But they believe their academic successes have…

  11. Agreement in Measurement of Optic Cup-to-Disc Ratio with Stereo Biomicroscope Funduscopy and Digital Image Analysis: Results from the Nigeria National Blindness and Visual Impairment Survey.

    Science.gov (United States)

    Kyari, Fatima; Gilbert, Clare

    2017-02-01

    To determine agreement in estimations of vertical cup-to-disc ratio (VCDR) between clinical stereo-biomicroscopic funduscopy and digital fundus image analysis. Systematic sampling of 1-in-7 from a sample of 13,591 participants aged ≥40 years gave a subsample who were examined in detail. VCDR was estimated clinically by 60 diopter aspheric lens biomicroscopic funduscopy (c-VCDR) and by digital fundus images (i-VCDR) graded at the Moorfields Eye Hospital Reading Centre. Spearman's correlation coefficient, paired t-test and the Bland-Altman method to assess limits of agreement (LOA) between the two methods were applied. Of 1759 participants in the subsample, 848 participants (48%) with normal frequency doubling technology (FDT) visual fields and data for i-VCDR and c-VCDR in both eyes (n = 1696 eyes) were included in the analysis. By absolute difference of VCDR values for each eye between the two methods, 1585 eyes (94%) differed by ≤0.2. Mean i-VCDR was 0.381 (standard deviation, SD 0.156), and mean c-VCDR 0.321 (SD 0.145). i-VCDRs were significantly larger by a mean difference of 0.061 (SD 0.121; 95% confidence interval, CI, 0.055-0.066; p method were lower limit -0.182 (95% CI -0.192 to -0.172) and upper limit 0.303 (95% CI 0.293-0.313). The 95% LOA intervals narrowed with higher VCDR. Digital image analysis and clinical assessment are two distinct methods to measure VCDR; with larger i-VCDRs in this survey. Applying i-VCDR cut-off values to c-VCDR measurements in the Nigeria Blindness Survey might have underestimated glaucoma prevalence. It is recommended that all participants in glaucoma surveys have VCDR by digital image measurement.

  12. Digital TV, advertising and audience

    Directory of Open Access Journals (Sweden)

    Ângelo Cruz

    2011-04-01

    Full Text Available This article aims to analyze the advertisingsegment and their relationship with the development process of the digital television. We intent to observe the new perspectives of production and consumption of media. Among other things, that involves the issues of interactivity, the exhaustion of the traditional media models, and the relationship of the new media with the audience, considering the analysis of the tripod: digital television, advertising and audience. In Brazil, with the implementation of the Brazilian System of Digital Television (SBTVD, the problem takes bigger proportions, as a consequence of the possibility to issue and track down the digital content consumed. That happens as a consequence of the consumer ability to watch the program withor without the commercial break. At the current model of television, the public is the legitimizing factor: the broadcasters issues the public a ention asan instrument to obtain pecuniary rewarding of theadvertisers. That model constitutes itself as the main funding source of the channels and networks. On the one hand, digital television represents an advantage at the quality of picture and audio, multiplying the capacity to transmit television signals and to transport new features and services. On the other hand, it seems impossible to transform this industry without some reaction. The many interests involved constitute the main cause of that scenario: the agents interested in advertising are those concerned with the role of ideology, the support of capitalism and the industrial culture. Considering all these questions, it seems almost impossible to produce deep chances,contrary to the interests involved.

  13. Agreement between clinical estimation and a new quantitative analysis by Photoshop software in fundus and angiographic image variables.

    Science.gov (United States)

    Ramezani, Alireza; Ahmadieh, Hamid; Azarmina, Mohsen; Soheilian, Masoud; Dehghan, Mohammad H; Mohebbi, Mohammad R

    2009-12-01

    To evaluate the validity of a new method for the quantitative analysis of fundus or angiographic images using Photoshop 7.0 (Adobe, USA) software by comparing with clinical evaluation. Four hundred and eighteen fundus and angiographic images of diabetic patients were evaluated by three retina specialists and then by computing using Photoshop 7.0 software. Four variables were selected for comparison: amount of hard exudates (HE) on color pictures, amount of HE on red-free pictures, severity of leakage, and the size of the foveal avascular zone (FAZ). The coefficient of agreement (Kappa) between the two methods in the amount of HE on color and red-free photographs were 85% (0.69) and 79% (0.59), respectively. The agreement for severity of leakage was 72% (0.46). In the two methods for the evaluation of the FAZ size using the magic and lasso software tools, the agreement was 54% (0.09) and 89% (0.77), respectively. Agreement in the estimation of the FAZ size by the lasso magnetic tool was excellent and was almost as good in the quantification of HE on color and on red-free images. Considering the agreement of this new technique for the measurement of variables in fundus images using Photoshop software with the clinical evaluation, this method seems to have sufficient validity to be used for the quantitative analysis of HE, leakage, and FAZ size on the angiograms of diabetic patients.

  14. Retinal pigment epithelial changes in chronic Vogt-Koyanagi-Harada disease: fundus autofluorescence and spectral domain optical coherence tomography findings

    Science.gov (United States)

    Vasconcelos-Santos, Daniel V.; Sohn, Elliott H.; Sadda, Srinivas; Rao, Narsing A.

    2009-01-01

    Purpose To determine whether fundus autofluorescence (FAF) and spectral-domain optical coherence tomography (SD-OCT) imaging allows better assessment of RPE and outer retina (OR) in subjects with chronic VKH compared to examination and angiography alone. Methods Cross-sectional analysis of a series of seven consecutive patients with chronic VKH undergoing FAF and SD-OCT. Chronic VKH was defined as during >3 months. Color fundus photographs were correlated to FAF and SD-OCT images. The images were later correlated to fluorescein angiography (FA) and indocyanine green angiography (ICG-A). Results All patients had sunset glow fundus, which resulted in no apparent corresponding abnormality on FAF or SD-OCT. Lesions with decreased autofluorescence signal were observed in 11 eyes (85%), being associated with loss of the RPE and involvement of OR on SD-OCT. In 5 eyes (38%) some of these lesions were very subtle on clinical examination but easily detected by FAF. Lesions with increased autofluorescence signal were seen in 8 eyes (61.5%), showing variable involvement of the OR on SD-OCT and corresponding clinically to areas of RPE proliferation and cystoid macular edema. Conclusion Combined use of FAF and SD-OCT imaging allowed noninvasive delineation of RPE/OR changes in patients with chronic VKH, which were consistent with previous histopathological reports. Some of these changes were not apparent on clinical examination. PMID:20010321

  15. The Nonmydriatic Fundus Camera in Diabetic Retinopathy Screening: A Cost-Effective Study with Evaluation for Future Large-Scale Application

    Directory of Open Access Journals (Sweden)

    Giuseppe Scarpa

    2016-01-01

    Full Text Available Aims. The study aimed to present the experience of a screening programme for early detection of diabetic retinopathy (DR using a nonmydriatic fundus camera, evaluating the feasibility in terms of validity, resources absorption, and future advantages of a potential application, in an Italian local health authority. Methods. Diabetic patients living in the town of Ponzano, Veneto Region (Northern Italy, were invited to be enrolled in the screening programme. The “no prevention strategy” with the inclusion of the estimation of blindness related costs was compared with screening costs in order to evaluate a future extensive and feasible implementation of the procedure, through a budget impact approach. Results. Out of 498 diabetic patients eligible, 80% was enrolled in the screening programme. 115 patients (34% were referred to an ophthalmologist and 9 cases required prompt treatment for either proliferative DR or macular edema. Based on the pilot data, it emerged that an extensive use of the investigated screening programme, within the Greater Treviso area, could prevent 6 cases of blindness every year, resulting in a saving of €271,543.32 (−13.71%. Conclusions. Fundus images obtained with a nonmydriatic fundus camera could be considered an effective, cost-sparing, and feasible screening tool for the early detection of DR, preventing blindness as a result of diabetes.

  16. Fast digitizing and digital signal processing of detector signals

    International Nuclear Information System (INIS)

    Hannaske, Roland

    2008-01-01

    A fast-digitizer data acquisition system recently installed at the neutron time-of-flight experiment nELBE, which is located at the superconducting electron accelerator ELBE of Forschungszentrum Dresden-Rossendorf, is tested with two different detector types. Preamplifier signals from a high-purity germanium detector are digitized, stored and finally processed. For a precise determination of the energy of the detected radiation, the moving-window deconvolution algorithm is used to compensate the ballistic deficit and different shaping algorithms are applied. The energy resolution is determined in an experiment with γ-rays from a 22 Na source and is compared to the energy resolution achieved with analogously processed signals. On the other hand, signals from the photomultipliers of barium fluoride and plastic scintillation detectors are digitized. These signals have risetimes of a few nanoseconds only. The moment of interaction of the radiation with the detector is determined by methods of digital signal processing. Therefore, different timing algorithms are implemented and tested with data from an experiment at nELBE. The time resolutions achieved with these algorithms are compared to each other as well as to reference values coming from analog signal processing. In addition to these experiments, some properties of the digitizing hardware are measured and a program for the analysis of stored, digitized data is developed. The analysis of the signals shows that the energy resolution achieved with the 10-bit digitizer system used here is not competitive to a 14-bit peak-sensing ADC, although the ballistic deficit can be fully corrected. However, digital methods give better result in sub-ns timing than analog signal processing. (orig.)

  17. What Is Digital Labour? What Is Digital Work? What’s their Difference? And Why Do These Questions Matter for Understanding Social Media?

    Directory of Open Access Journals (Sweden)

    Christian Fuchs

    2013-06-01

    Full Text Available This paper deals with the questions: What is digital labour? What is digital work? Based on Marx’s theory, we distinguish between work and labour as anthropological and historical forms of human activity. The notion of alienated labour is grounded in a general model of the work process that is conceptualized based on a dialectic of subject and object in the economy that we present in the form of a model, the Hegelian-Marxist dialectical triangle of the work process. Various aspects of a Marxist theory of work and labour, such as the notions of abstract and concrete labour, double-free labour, productive labour, the collective worker and general work are presented. Labour is based on a fourfold alienation of the human being. After these concepts are introduced, they are used for discussing the notions of digital labour and digital work. The presentation is on the one hand general and on the other hand uses Facebook as a concrete case for explaining how digital labour functions. Digital work is the organisation of human experiences with the help of the human brain, digital media and speech in such a way that new products are created. Digital labour is the valorisation dimension of digital work. We conclude that we require the transformation of digital labour into digital work, a true social media revolution that makes “social media” truly and fully social. We also argue why in our view work is not the same as labour by discussing the concept of playful work and pointing out limits of concepts such as antiwork, postwork and zerowork.

  18. Prevalence of Hand-transmitted Vibration Exposure among Grass-cutting Workers using Objective and Subjective Measures

    Science.gov (United States)

    Azmir, N. A.; Yahya, M. N.

    2017-01-01

    Extended exposure to hand-transmitted vibration from vibrating machine is associated with an increased occurrence of symptoms of occupational disease related to hand disorder. The present case study is to determine the prevalence and correlation of significant subjective as well as objective variables that induce to hand arm vibration syndrome (HAVS) among hand-held grass-cutting workers in Malaysia. Thus, recommendations are made for grass-cutting workers and grass maintenance service management based on findings. A cross sectional study using adopted subjective Hand Arm Vibration Exposure Risk Assessment (HAVERA) questionnaire from Vibration Injury Network on hand disorder signs and symptoms was distributed to a sample of one hundred and sixty eight male workers from grass and turf maintenance industry that use vibrating machine as part of their work. For objective measure, hand-transmitted vibration measurement was collected on site during operation by the following ISO 5349-1, 2001. Two groups were identified in this research comprising of high exposure group and low-moderate exposure group. Workers also gave information about their personal identification, social history, workers’ health, occupational history and machine safety inspection. There was positive HAVS symptoms relationship between the low-moderate exposure group and high exposure group among hand-held grass-cutting workers. The prevalence ratio (PR) was considered high for experiencing white colour change at fingers and fingers go numb which are 3.63 (1.41 to 9.39) and 4.24 (2.18 to 8.27), respectively. The estimated daily vibration exposure, A(8) differs between 2.1 to 20.7 ms-2 for right hand while 2.7 to 29.1 ms-2 for left hand. The subjects claimed that the feel of numbness at left hand is much stronger compared to right hand. The results suggest that HAVS is diagnosed in Malaysia especially in agriculture sector. The A(8) indicates that the exposure value is more than exposure limit value

  19. Interactive Digital Narratives for iTV and Online Video

    NARCIS (Netherlands)

    Koenitz, H.; Knoller, N.; Nakatsu, R.; Rauterberg, M.; Ciancarini, P.

    2015-01-01

    In iTV and online video, narrative interaction has long been a Holy Grail for both audiences and creators of these digital audiovisual works. On the one hand, interactive digital narrative promises interactors some exciting opportunities: to enter the world of the story, to affect the story and

  20. EARLY SIMULTANEOUS FUNDUS AUTOFLUORESCENCE AND OPTICAL COHERENCE TOMOGRAPHY FEATURES AFTER PARS PLANA VITRECTOMY FOR PRIMARY RHEGMATOGENOUS RETINAL DETACHMENT

    NARCIS (Netherlands)

    Dellʼomo, Roberto; Mura, Marco; Lesnik Oberstein, Sarit Y.; Bijl, Heico; Tan, H. Stevie

    2012-01-01

    Purpose: To describe fundus autofluorescence and optical coherence tomography (OCT) features of the macula after pars plana vitrectomy for rhegmatogenous retinal detachment. Methods: Thirty-three eyes of 33 consecutive patients with repaired rhegmatogenous retinal detachment with or without the